Science.gov

Sample records for 3d scanning devices

  1. An efficient solid modeling system based on a hand-held 3D laser scan device

    NASA Astrophysics Data System (ADS)

    Xiong, Hanwei; Xu, Jun; Xu, Chenxi; Pan, Ming

    2014-12-01

    The hand-held 3D laser scanner sold in the market is appealing for its port and convenient to use, but price is expensive. To develop such a system based cheap devices using the same principles as the commercial systems is impossible. In this paper, a simple hand-held 3D laser scanner is developed based on a volume reconstruction method using cheap devices. Unlike convenient laser scanner to collect point cloud of an object surface, the proposed method only scan few key profile curves on the surface. Planar section curve network can be generated from these profile curves to construct a volume model of the object. The details of design are presented, and illustrated by the example of a complex shaped object.

  2. Underwater 3D Surface Measurement Using Fringe Projection Based Scanning Devices

    PubMed Central

    Bräuer-Burchardt, Christian; Heinze, Matthias; Schmidt, Ingo; Kühmstedt, Peter; Notni, Gunther

    2015-01-01

    In this work we show the principle of optical 3D surface measurements based on the fringe projection technique for underwater applications. The challenges of underwater use of this technique are shown and discussed in comparison with the classical application. We describe an extended camera model which takes refraction effects into account as well as a proposal of an effective, low-effort calibration procedure for underwater optical stereo scanners. This calibration technique combines a classical air calibration based on the pinhole model with ray-based modeling and requires only a few underwater recordings of an object of known length and a planar surface. We demonstrate a new underwater 3D scanning device based on the fringe projection technique. It has a weight of about 10 kg and the maximal water depth for application of the scanner is 40 m. It covers an underwater measurement volume of 250 mm × 200 mm × 120 mm. The surface of the measurement objects is captured with a lateral resolution of 150 μm in a third of a second. Calibration evaluation results are presented and examples of first underwater measurements are given. PMID:26703624

  3. 3D Scan Systems Integration

    DTIC Science & Technology

    2007-11-02

    AGENCY USE ONLY (Leave Blank) 2. REPORT DATE 5 Feb 98 4. TITLE AND SUBTITLE 3D Scan Systems Integration REPORT TYPE AND DATES COVERED...2-89) Prescribed by ANSI Std. Z39-1 298-102 [ EDO QUALITY W3PECTEDI DLA-ARN Final Report for US Defense Logistics Agency on DDFG-T2/P3: 3D...SCAN SYSTEMS INTEGRATION Contract Number SPO100-95-D-1014 Contractor Ohio University Delivery Order # 0001 Delivery Order Title 3D Scan Systems

  4. 3D elastic control for mobile devices.

    PubMed

    Hachet, Martin; Pouderoux, Joachim; Guitton, Pascal

    2008-01-01

    To increase the input space of mobile devices, the authors developed a proof-of-concept 3D elastic controller that easily adapts to mobile devices. This embedded device improves the completion of high-level interaction tasks such as visualization of large documents and navigation in 3D environments. It also opens new directions for tomorrow's mobile applications.

  5. Optical microcavity scanning 3D tomography.

    PubMed

    Di Donato, Andrea; Criante, Luigino; LoTurco, Sara; Farina, Marco

    2014-10-01

    A scanning optical microcavity is exploited to achieve lens-free 3D tomography of microfluidic channels. The microcavity, powered by a low-coherence source, is realized by approaching a cleaved fiber to few tens of micrometers over the sample. The interference of scattered waves inside the cavity shapes the transverse field distribution by focusing the beam and overcoming the diffraction limit due to the optical-fiber numerical aperture. The focusing effect is also preserved in the inner layers of the sample, allowing optical 3D tomography. Analysis of microfluidic channels was demonstrated through this noninvasive technique. Although the experimental setup recalls the well-known fiber-optic Fourier-domain common-path optical coherence tomography, the proposed method has intrinsic characteristics that distinguish it from the former one.

  6. Slate characterization using 3D laser scanning

    NASA Astrophysics Data System (ADS)

    López, M.; Taboada, J.; Martínez, J.; Matías, J. M.; Vilán, J. A.

    2012-12-01

    Quality control is a necessary component of the slate slab manufacturing process so as to evaluate defects as defined by the current standard for slate. Quality control has traditionally been performed manually by an expert in the field, with the consequent human subjectivity. We studied the feasibility of using a 3D laser scanner to measure slate slabs and analyze possible defects that would lead to the rejection of slabs for particular industrial processes. The application requires slate characterization to be performed in real time and thereby requires a short computation time. We describe an optimized calibration method based on Tsai's approach that reduces calculation complexity and cost in this key 3D laser scanning stage. Configured and implemented for slate slab characterization, the system produces the required information in real time during the production process.

  7. 3D-printed bioanalytical devices

    NASA Astrophysics Data System (ADS)

    Bishop, Gregory W.; Satterwhite-Warden, Jennifer E.; Kadimisetty, Karteek; Rusling, James F.

    2016-07-01

    While 3D printing technologies first appeared in the 1980s, prohibitive costs, limited materials, and the relatively small number of commercially available printers confined applications mainly to prototyping for manufacturing purposes. As technologies, printer cost, materials, and accessibility continue to improve, 3D printing has found widespread implementation in research and development in many disciplines due to ease-of-use and relatively fast design-to-object workflow. Several 3D printing techniques have been used to prepare devices such as milli- and microfluidic flow cells for analyses of cells and biomolecules as well as interfaces that enable bioanalytical measurements using cellphones. This review focuses on preparation and applications of 3D-printed bioanalytical devices.

  8. Scanning 3D full human bodies using Kinects.

    PubMed

    Tong, Jing; Zhou, Jin; Liu, Ligang; Pan, Zhigeng; Yan, Hao

    2012-04-01

    Depth camera such as Microsoft Kinect, is much cheaper than conventional 3D scanning devices, and thus it can be acquired for everyday users easily. However, the depth data captured by Kinect over a certain distance is of extreme low quality. In this paper, we present a novel scanning system for capturing 3D full human body models by using multiple Kinects. To avoid the interference phenomena, we use two Kinects to capture the upper part and lower part of a human body respectively without overlapping region. A third Kinect is used to capture the middle part of the human body from the opposite direction. We propose a practical approach for registering the various body parts of different views under non-rigid deformation. First, a rough mesh template is constructed and used to deform successive frames pairwisely. Second, global alignment is performed to distribute errors in the deformation space, which can solve the loop closure problem efficiently. Misalignment caused by complex occlusion can also be handled reasonably by our global alignment algorithm. The experimental results have shown the efficiency and applicability of our system. Our system obtains impressive results in a few minutes with low price devices, thus is practically useful for generating personalized avatars for everyday users. Our system has been used for 3D human animation and virtual try on, and can further facilitate a range of home–oriented virtual reality (VR) applications.

  9. Integrating visible light 3D scanning into the everyday world

    NASA Astrophysics Data System (ADS)

    Straub, Jeremy

    2015-05-01

    Visible light 3D scanning offers the potential to non-invasively and nearly non-perceptibly incorporate 3D imaging into the everyday world. This paper considers the various possible uses of visible light 3D scanning technology. It discusses multiple possible usage scenarios including in hospitals, security perimeter settings and retail environments. The paper presents a framework for assessing the efficacy of visible light 3D scanning for a given application (and compares this to other scanning approaches such as those using blue light or lasers). It also discusses ethical and legal considerations relevant to real-world use and concludes by presenting a decision making framework.

  10. Development of a 3-D Pen Input Device

    DTIC Science & Technology

    2008-09-01

    remote sites. Compared to other distance learning technologies such as video cameras, the 3-D pen input device would require much less bandwidth. The...other form of eLearning portal. However with a pen-type input device, the professors are saved the trouble of either rewriting their notes or copying...and scanning the notes then uploading them into a form of eLearning , then broadcasting them for the distance learning students. Instead, the

  11. 3D Participatory Sensing with Low-Cost Mobile Devices for Crop Height Assessment--A Comparison with Terrestrial Laser Scanning Data.

    PubMed

    Marx, Sabrina; Hämmerle, Martin; Klonner, Carolin; Höfle, Bernhard

    2016-01-01

    The integration of local agricultural knowledge deepens the understanding of complex phenomena such as the association between climate variability, crop yields and undernutrition. Participatory Sensing (PS) is a concept which enables laymen to easily gather geodata with standard low-cost mobile devices, offering new and efficient opportunities for agricultural monitoring. This study presents a methodological approach for crop height assessment based on PS. In-field crop height variations of a maize field in Heidelberg, Germany, are gathered with smartphones and handheld GPS devices by 19 participants. The comparison of crop height values measured by the participants to reference data based on terrestrial laser scanning (TLS) results in R2 = 0.63 for the handheld GPS devices and R2 = 0.24 for the smartphone-based approach. RMSE for the comparison between crop height models (CHM) derived from PS and TLS data is 10.45 cm (GPS devices) and 14.69 cm (smartphones). Furthermore, the results indicate that incorporating participants' cognitive abilities in the data collection process potentially improves the quality data captured with the PS approach. The proposed PS methods serve as a fundament to collect agricultural parameters on field-level by incorporating local people. Combined with other methods such as remote sensing, PS opens new perspectives to support agricultural development.

  12. 3D Participatory Sensing with Low-Cost Mobile Devices for Crop Height Assessment – A Comparison with Terrestrial Laser Scanning Data

    PubMed Central

    Marx, Sabrina; Hämmerle, Martin; Klonner, Carolin; Höfle, Bernhard

    2016-01-01

    The integration of local agricultural knowledge deepens the understanding of complex phenomena such as the association between climate variability, crop yields and undernutrition. Participatory Sensing (PS) is a concept which enables laymen to easily gather geodata with standard low-cost mobile devices, offering new and efficient opportunities for agricultural monitoring. This study presents a methodological approach for crop height assessment based on PS. In-field crop height variations of a maize field in Heidelberg, Germany, are gathered with smartphones and handheld GPS devices by 19 participants. The comparison of crop height values measured by the participants to reference data based on terrestrial laser scanning (TLS) results in R2 = 0.63 for the handheld GPS devices and R2 = 0.24 for the smartphone-based approach. RMSE for the comparison between crop height models (CHM) derived from PS and TLS data is 10.45 cm (GPS devices) and 14.69 cm (smartphones). Furthermore, the results indicate that incorporating participants’ cognitive abilities in the data collection process potentially improves the quality data captured with the PS approach. The proposed PS methods serve as a fundament to collect agricultural parameters on field-level by incorporating local people. Combined with other methods such as remote sensing, PS opens new perspectives to support agricultural development. PMID:27073917

  13. Parsing optical scanned 3D data by Bayesian inference

    NASA Astrophysics Data System (ADS)

    Xiong, Hanwei; Xu, Jun; Xu, Chenxi; Pan, Ming

    2015-10-01

    Optical devices are always used to digitize complex objects to get their shapes in form of point clouds. The results have no semantic meaning about the objects, and tedious process is indispensable to segment the scanned data to get meanings. The reason for a person to perceive an object correctly is the usage of knowledge, so Bayesian inference is used to the goal. A probabilistic And-Or-Graph is used as a unified framework of representation, learning, and recognition for a large number of object categories, and a probabilistic model defined on this And-Or-Graph is learned from a relatively small training set per category. Given a set of 3D scanned data, the Bayesian inference constructs a most probable interpretation of the object, and a semantic segment is obtained from the part decomposition. Some examples are given to explain the method.

  14. Array servo scanning micro EDM of 3D micro cavities

    NASA Astrophysics Data System (ADS)

    Tong, Hao; Li, Yong; Yi, Futing

    2010-12-01

    Micro electro discharge machining (Micro EDM) is a non-traditional processing technology with the special advantages of low set-up cost and few cutting force in machining any conductive materials regardless of their hardness. As well known, die-sinking EDM is unsuitable for machining the complex 3D micro cavity less than 1mm due to the high-priced fabrication of 3D microelectrode itself and its serous wear during EDM process. In our former study, a servo scanning 3D micro-EDM (3D SSMEDM) method was put forward, and our experiments showed it was available to fabricate complex 3D micro-cavities. In this study, in order to improve machining efficiency and consistency accuracy for array 3D micro-cavities, an array-servo-scanning 3D micro EDM (3D ASSMEDM) method is presented considering the complementary advantages of the 3D SSMEDM and the array micro electrodes with simple cross-section. During 3D ASSMEDM process, the array cavities designed by CAD / CAM system can be batch-manufactured by servo scanning layer by layer using array-rod-like micro tool electrodes, and the axial wear of the array electrodes is compensated in real time by keeping discharge gap. To verify the effectiveness of the 3D ASSMEDM, the array-triangle-micro cavities (side length 630 μm) are batch-manufactured on P-doped silicon by applying the array-micro-electrodes with square-cross-section fabricated by LIGA process. Our exploratory experiment shows that the 3D ASSMEDM provides a feasible approach for the batch-manufacture of 3D array-micro-cavities of conductive materials.

  15. Array servo scanning micro EDM of 3D micro cavities

    NASA Astrophysics Data System (ADS)

    Tong, Hao; Li, Yong; Yi, Futing

    2011-05-01

    Micro electro discharge machining (Micro EDM) is a non-traditional processing technology with the special advantages of low set-up cost and few cutting force in machining any conductive materials regardless of their hardness. As well known, die-sinking EDM is unsuitable for machining the complex 3D micro cavity less than 1mm due to the high-priced fabrication of 3D microelectrode itself and its serous wear during EDM process. In our former study, a servo scanning 3D micro-EDM (3D SSMEDM) method was put forward, and our experiments showed it was available to fabricate complex 3D micro-cavities. In this study, in order to improve machining efficiency and consistency accuracy for array 3D micro-cavities, an array-servo-scanning 3D micro EDM (3D ASSMEDM) method is presented considering the complementary advantages of the 3D SSMEDM and the array micro electrodes with simple cross-section. During 3D ASSMEDM process, the array cavities designed by CAD / CAM system can be batch-manufactured by servo scanning layer by layer using array-rod-like micro tool electrodes, and the axial wear of the array electrodes is compensated in real time by keeping discharge gap. To verify the effectiveness of the 3D ASSMEDM, the array-triangle-micro cavities (side length 630 μm) are batch-manufactured on P-doped silicon by applying the array-micro-electrodes with square-cross-section fabricated by LIGA process. Our exploratory experiment shows that the 3D ASSMEDM provides a feasible approach for the batch-manufacture of 3D array-micro-cavities of conductive materials.

  16. 3D scanning and 3D printing as innovative technologies for fabricating personalized topical drug delivery systems.

    PubMed

    Goyanes, Alvaro; Det-Amornrat, Usanee; Wang, Jie; Basit, Abdul W; Gaisford, Simon

    2016-07-28

    Acne is a multifactorial inflammatory skin disease with high prevalence. In this work, the potential of 3D printing to produce flexible personalised-shape anti-acne drug (salicylic acid) loaded devices was demonstrated by two different 3D printing (3DP) technologies: Fused Deposition Modelling (FDM) and stereolithography (SLA). 3D scanning technology was used to obtain a 3D model of a nose adapted to the morphology of an individual. In FDM 3DP, commercially produced Flex EcoPLA™ (FPLA) and polycaprolactone (PCL) filaments were loaded with salicylic acid by hot melt extrusion (HME) (theoretical drug loading - 2% w/w) and used as feedstock material for 3D printing. Drug loading in the FPLA-salicylic acid and PCL-salicylic acid 3D printed patches was 0.4% w/w and 1.2% w/w respectively, indicating significant thermal degradation of drug during HME and 3D printing. Diffusion testing in Franz cells using a synthetic membrane revealed that the drug loaded printed samples released <187μg/cm(2) within 3h. FPLA-salicylic acid filament was successfully printed as a nose-shape mask by FDM 3DP, but the PCL-salicylic acid filament was not. In the SLA printing process, the drug was dissolved in different mixtures of poly(ethylene glycol) diacrylate (PEGDA) and poly(ethylene glycol) (PEG) that were solidified by the action of a laser beam. SLA printing led to 3D printed devices (nose-shape) with higher resolution and higher drug loading (1.9% w/w) than FDM, with no drug degradation. The results of drug diffusion tests revealed that drug diffusion was faster than with the FDM devices, 229 and 291μg/cm(2) within 3h for the two formulations evaluated. In this study, SLA printing was the more appropriate 3D printing technology to manufacture anti-acne devices with salicylic acid. The combination of 3D scanning and 3D printing has the potential to offer solutions to produce personalised drug loaded devices, adapted in shape and size to individual patients.

  17. The dimension added by 3D scanning and 3D printing of meteorites

    NASA Astrophysics Data System (ADS)

    de Vet, S. J.

    2016-01-01

    An overview for the 3D photodocumentation of meteorites is presented, focussing on two 3D scanning methods in relation to 3D printing. The 3D photodocumention of meteorites provides new ways for the digital preservation of culturally, historically or scientifically unique meteorites. It has the potential for becoming a new documentation standard of meteorites that can exist complementary to traditional photographic documentation. Notable applications include (i.) use of physical properties in dark flight-, strewn field-, or aerodynamic modelling; (ii.) collection research of meteorites curated by different museum collections, and (iii.) public dissemination of meteorite models as a resource for educational users. The possible applications provided by the additional dimension of 3D illustrate the benefits for the meteoritics community.

  18. Development of a 3D printer using scanning projection stereolithography

    PubMed Central

    Lee, Michael P.; Cooper, Geoffrey J. T.; Hinkley, Trevor; Gibson, Graham M.; Padgett, Miles J.; Cronin, Leroy

    2015-01-01

    We have developed a system for the rapid fabrication of low cost 3D devices and systems in the laboratory with micro-scale features yet cm-scale objects. Our system is inspired by maskless lithography, where a digital micromirror device (DMD) is used to project patterns with resolution up to 10 µm onto a layer of photoresist. Large area objects can be fabricated by stitching projected images over a 5cm2 area. The addition of a z-stage allows multiple layers to be stacked to create 3D objects, removing the need for any developing or etching steps but at the same time leading to true 3D devices which are robust, configurable and scalable. We demonstrate the applications of the system by printing a range of micro-scale objects as well as a fully functioning microfluidic droplet device and test its integrity by pumping dye through the channels. PMID:25906401

  19. Development of a 3D printer using scanning projection stereolithography.

    PubMed

    Lee, Michael P; Cooper, Geoffrey J T; Hinkley, Trevor; Gibson, Graham M; Padgett, Miles J; Cronin, Leroy

    2015-04-23

    We have developed a system for the rapid fabrication of low cost 3D devices and systems in the laboratory with micro-scale features yet cm-scale objects. Our system is inspired by maskless lithography, where a digital micromirror device (DMD) is used to project patterns with resolution up to 10 µm onto a layer of photoresist. Large area objects can be fabricated by stitching projected images over a 5 cm(2) area. The addition of a z-stage allows multiple layers to be stacked to create 3D objects, removing the need for any developing or etching steps but at the same time leading to true 3D devices which are robust, configurable and scalable. We demonstrate the applications of the system by printing a range of micro-scale objects as well as a fully functioning microfluidic droplet device and test its integrity by pumping dye through the channels.

  20. 3D scanning and printing skeletal tissues for anatomy education.

    PubMed

    Thomas, Daniel B; Hiscox, Jessica D; Dixon, Blair J; Potgieter, Johan

    2016-09-01

    Detailed anatomical models can be produced with consumer-level 3D scanning and printing systems. 3D replication techniques are significant advances for anatomical education as they allow practitioners to more easily introduce diverse or numerous specimens into classrooms. Here we present a methodology for producing anatomical models in-house, with the chondrocranium cartilage from a spiny dogfish (Squalus acanthias) and the skeleton of a cane toad (Rhinella marina) as case studies. 3D digital replicas were produced using two consumer-level scanners and specimens were 3D-printed with selective laser sintering. The fidelity of the two case study models was determined with respect to key anatomical features. Larger-scale features of the dogfish chondrocranium and frog skeleton were all well-resolved and distinct in the 3D digital models, and many finer-scale features were also well-resolved, but some more subtle features were absent from the digital models (e.g. endolymphatic foramina in chondrocranium). All characters identified in the digital chondrocranium could be identified in the subsequent 3D print; however, three characters in the 3D-printed frog skeleton could not be clearly delimited (palatines, parasphenoid and pubis). Characters that were absent in the digital models or 3D prints had low-relief in the original scanned specimen and represent a minor loss of fidelity. Our method description and case studies show that minimal equipment and training is needed to produce durable skeletal specimens. These technologies support the tailored production of models for specific classes or research aims.

  1. A semi-automatic 3D laser scan system design

    NASA Astrophysics Data System (ADS)

    Xiong, Hanwei; Pan, Ming; Zhang, Xiangwei

    2009-11-01

    Digital 3D models are now used everywhere, from traditional fields of industrial design, artistic design, to heritage conservation. Although laser scan is very useful to get densely samples of the objects, nowadays, such an instrument is expensive and always need to be connected to a computer with stable power supply, which prevent it from usage for fieldworks. In this paper, a new semi-automatic 3D laser scan method is proposed using two line laser sources. The planes projected from the laser sources are orthogonal, one of which is fixed relative to the camera, and the other can be rotated along a settled axis. Before scanning, the system must be calibrated, from which the parameters of the camera, the position of the fixed laser plane and the settled axis are introduced. In scanning process, the fixed laser plane and the camera form a conventional structured light system, and the 3d positions of the intersection curves of the fixed laser plane with the object can be computed. The other laser plane is rotated manually or mechanically, and its position can be determined from the cross point intersecting with the fixed laser plane on the object, so the coordinates of sweeping points can be obtained. The new system can be used without a computer (The data can be processed later), which make it suitable for fieldworks. A scanning case is given in the end.

  2. A microfluidic device for 2D to 3D and 3D to 3D cell navigation

    NASA Astrophysics Data System (ADS)

    Shamloo, Amir; Amirifar, Leyla

    2016-01-01

    Microfluidic devices have received wide attention and shown great potential in the field of tissue engineering and regenerative medicine. Investigating cell response to various stimulations is much more accurate and comprehensive with the aid of microfluidic devices. In this study, we introduced a microfluidic device by which the matrix density as a mechanical property and the concentration profile of a biochemical factor as a chemical property could be altered. Our microfluidic device has a cell tank and a cell culture chamber to mimic both 2D to 3D and 3D to 3D migration of three types of cells. Fluid shear stress is negligible on the cells and a stable concentration gradient can be obtained by diffusion. The device was designed by a numerical simulation so that the uniformity of the concentration gradients throughout the cell culture chamber was obtained. Adult neural cells were cultured within this device and they showed different branching and axonal navigation phenotypes within varying nerve growth factor (NGF) concentration profiles. Neural stem cells were also cultured within varying collagen matrix densities while exposed to NGF concentrations and they experienced 3D to 3D collective migration. By generating vascular endothelial growth factor concentration gradients, adult human dermal microvascular endothelial cells also migrated in a 2D to 3D manner and formed a stable lumen within a specific collagen matrix density. It was observed that a minimum absolute concentration and concentration gradient were required to stimulate migration of all types of the cells. This device has the advantage of changing multiple parameters simultaneously and is expected to have wide applicability in cell studies.

  3. Pavement cracking measurements using 3D laser-scan images

    NASA Astrophysics Data System (ADS)

    Ouyang, W.; Xu, B.

    2013-10-01

    Pavement condition surveying is vital for pavement maintenance programs that ensure ride quality and traffic safety. This paper first introduces an automated pavement inspection system which uses a three-dimensional (3D) camera and a structured laser light to acquire dense transverse profiles of a pavement lane surface when it carries a moving vehicle. After the calibration, the 3D system can yield a depth resolution of 0.5 mm and a transverse resolution of 1.56 mm pixel-1 at 1.4 m camera height from the ground. The scanning rate of the camera can be set to its maximum at 5000 lines s-1, allowing the density of scanned profiles to vary with the vehicle's speed. The paper then illustrates the algorithms that utilize 3D information to detect pavement distress, such as transverse, longitudinal and alligator cracking, and presents the field tests on the system's repeatability when scanning a sample pavement in multiple runs at the same vehicle speed, at different vehicle speeds and under different weather conditions. The results show that this dedicated 3D system can capture accurate pavement images that detail surface distress, and obtain consistent crack measurements in repeated tests and under different driving and lighting conditions.

  4. Will true 3d display devices aid geologic interpretation. [Mirage

    SciTech Connect

    Nelson, H.R. Jr.

    1982-04-01

    A description is given of true 3D display devices and techniques that are being evaluated in various research laboratories around the world. These advances are closely tied to the expected application of 3D display devices as interpretational tools for explorationists. 34 refs.

  5. Automatic scan registration using 3D linear and planar features

    NASA Astrophysics Data System (ADS)

    Yao, Jian; Ruggeri, Mauro R.; Taddei, Pierluigi; Sequeira, Vítor

    2010-09-01

    We present a common framework for accurate and automatic registration of two geometrically complex 3D range scans by using linear or planar features. The linear features of a range scan are extracted with an efficient split-and-merge line-fitting algorithm, which refines 2D edges extracted from the associated reflectance image considering the corresponding 3D depth information. The planar features are extracted employing a robust planar segmentation method, which partitions a range image into a set of planar patches. We propose an efficient probability-based RANSAC algorithm to automatically register two overlapping range scans. Our algorithm searches for matching pairs of linear (planar) features in the two range scans leading to good alignments. Line orientation (plane normal) angles and line (plane) distances formed by pairs of linear (planar) features are invariant with respect to the rigid transformation and are utilized to find candidate matches. To efficiently seek for candidate pairs and groups of matched features we build a fast search codebook. Given two sets of matched features, the rigid transformation between two scans is computed by using iterative linear optimization algorithms. The efficiency and accuracy of our registration algorithm were evaluated on several challenging range data sets.

  6. A hand-held 3D laser scanning with global positioning system of subvoxel precision

    NASA Astrophysics Data System (ADS)

    Arias, Néstor; Meneses, Néstor; Meneses, Jaime; Gharbi, Tijani

    2011-01-01

    In this paper we propose a hand-held 3D laser scanner composed of an optical head device to extract 3D local surface information and a stereo vision system with subvoxel precision to measure the position and orientation of the 3D optical head. The optical head is manually scanned over the surface object by the operator. The orientation and position of the 3D optical head is determined by a phase-sensitive method using a 2D regular intensity pattern. This phase reference pattern is rigidly fixed to the optical head and allows their 3D location with subvoxel precision in the observation field of the stereo vision system. The 3D resolution achieved by the stereo vision system is about 33 microns at 1.8 m with an observation field of 60cm x 60cm.

  7. 3D surface and body documentation in forensic medicine: 3-D/CAD Photogrammetry merged with 3D radiological scanning.

    PubMed

    Thali, Michael J; Braun, Marcel; Wirth, Joachim; Vock, Peter; Dirnhofer, Richard

    2003-11-01

    A main goal of forensic medicine is to document and to translate medical findings to a language and/or visualization that is readable and understandable for judicial persons and for medical laymen. Therefore, in addition to classical methods, scientific cutting-edge technologies can and should be used. Through the use of the Forensic, 3-D/CAD-supported Photogrammetric method the documentation of so-called "morphologic fingerprints" has been realized. Forensic, 3-D/CAD-supported Photogrammetry creates morphologic data models of the injury and of the suspected injury-causing instrument allowing the evaluation of a match between the injury and the instrument. In addition to the photogrammetric body surface registration, the radiological documentation provided by a volume scan (i.e., spiral, multi-detector CT, or MRI) registers the sub-surface injury, which is not visible to Photogrammetry. The new, combined method of merging Photogrammetry and Radiology data sets creates the potential to perform many kinds of reconstructions and postprocessing of (patterned) injuries in the realm of forensic medical case work. Using this merging method of colored photogrammetric surface and gray-scale radiological internal documentation, a great step towards a new kind of reality-based, high-tech wound documentation and visualization in forensic medicine is made. The combination of the methods of 3D/CAD Photogrammetry and Radiology has the advantage of being observer-independent, non-subjective, non-invasive, digitally storable over years or decades and even transferable over the web for second opinion.

  8. Scanning Acoustic Microscope of 3D-Interconnect

    NASA Astrophysics Data System (ADS)

    Wai Kong, Lay; Diebold, A. C.; Rudack, A.; Arkalgud, S.

    2009-09-01

    The College of Nanoscale Science and Engineering of the University at Albany in collaboration with International SEMATECH is investigating the use of Scanning Acoustic Microscope (SAM) for analyzing 3D Interconnects. SAM is a non-destructive metrology technique which utilizes high frequency ultrasound to generate a microscopic image of the internal parts of a specimen. The goal of this project is to develop microscopic techniques for evaluating Through-Silicon Vias (TSVs) for 3D-Interconnects. Preliminary data shows voids and other defects in the interface between bonded wafers as shown in Figure 1. Our SAM laboratory system operates at 230 MHz and has a spatial resolution of 5-10 μm and focal length of 5.9 mm on a silicon wafer. The spatial resolution and sampling depth depend on the ultrasonic frequency, sound velocity, focal length and diameter of piezoelectric crystal. Typically, the silicon wafers have a thickness of 775 μm before they are bonded. Our initial work is focused on blanket wafers in order to develop the bonding process. The next step is to bond wafers with test die where the patterning obscures the interface. This paper will discuss the limitations of SAM and compare it to infrared microscopy which is another important imaging capability for 3D Interconnect. We also discuss the current status of research into more advanced acoustic microscopy methods and how this might impact 3D Interconnect imaging.

  9. Low cost 3D scanning process using digital image processing

    NASA Astrophysics Data System (ADS)

    Aguilar, David; Romero, Carlos; Martínez, Fernando

    2017-02-01

    This paper shows the design and building of a low cost 3D scanner, able to digitize solid objects through contactless data acquisition, using active object reflection. 3D scanners are used in different applications such as: science, engineering, entertainment, etc; these are classified in: contact scanners and contactless ones, where the last ones are often the most used but they are expensive. This low-cost prototype is done through a vertical scanning of the object using a fixed camera and a mobile horizontal laser light, which is deformed depending on the 3-dimensional surface of the solid. Using digital image processing an analysis of the deformation detected by the camera was done; it allows determining the 3D coordinates using triangulation. The obtained information is processed by a Matlab script, which gives to the user a point cloud corresponding to each horizontal scanning done. The obtained results show an acceptable quality and significant details of digitalized objects, making this prototype (built on LEGO Mindstorms NXT kit) a versatile and cheap tool, which can be used for many applications, mainly by engineering students.

  10. Optimization Techniques for 3D Graphics Deployment on Mobile Devices

    NASA Astrophysics Data System (ADS)

    Koskela, Timo; Vatjus-Anttila, Jarkko

    2015-03-01

    3D Internet technologies are becoming essential enablers in many application areas including games, education, collaboration, navigation and social networking. The use of 3D Internet applications with mobile devices provides location-independent access and richer use context, but also performance issues. Therefore, one of the important challenges facing 3D Internet applications is the deployment of 3D graphics on mobile devices. In this article, we present an extensive survey on optimization techniques for 3D graphics deployment on mobile devices and qualitatively analyze the applicability of each technique from the standpoints of visual quality, performance and energy consumption. The analysis focuses on optimization techniques related to data-driven 3D graphics deployment, because it supports off-line use, multi-user interaction, user-created 3D graphics and creation of arbitrary 3D graphics. The outcome of the analysis facilitates the development and deployment of 3D Internet applications on mobile devices and provides guidelines for future research.

  11. Chest wall segmentation in automated 3D breast ultrasound scans.

    PubMed

    Tan, Tao; Platel, Bram; Mann, Ritse M; Huisman, Henkjan; Karssemeijer, Nico

    2013-12-01

    In this paper, we present an automatic method to segment the chest wall in automated 3D breast ultrasound images. Determining the location of the chest wall in automated 3D breast ultrasound images is necessary in computer-aided detection systems to remove automatically detected cancer candidates beyond the chest wall and it can be of great help for inter- and intra-modal image registration. We show that the visible part of the chest wall in an automated 3D breast ultrasound image can be accurately modeled by a cylinder. We fit the surface of our cylinder model to a set of automatically detected rib-surface points. The detection of the rib-surface points is done by a classifier using features representing local image intensity patterns and presence of rib shadows. Due to attenuation of the ultrasound signal, a clear shadow is visible behind the ribs. Evaluation of our segmentation method is done by computing the distance of manually annotated rib points to the surface of the automatically detected chest wall. We examined the performance on images obtained with the two most common 3D breast ultrasound devices in the market. In a dataset of 142 images, the average mean distance of the annotated points to the segmented chest wall was 5.59 ± 3.08 mm.

  12. 3D Printed Micro Free-Flow Electrophoresis Device.

    PubMed

    Anciaux, Sarah K; Geiger, Matthew; Bowser, Michael T

    2016-08-02

    The cost, time, and restrictions on creative flexibility associated with current fabrication methods present significant challenges in the development and application of microfluidic devices. Additive manufacturing, also referred to as three-dimensional (3D) printing, provides many advantages over existing methods. With 3D printing, devices can be made in a cost-effective manner with the ability to rapidly prototype new designs. We have fabricated a micro free-flow electrophoresis (μFFE) device using a low-cost, consumer-grade 3D printer. Test prints were performed to determine the minimum feature sizes that could be reproducibly produced using 3D printing fabrication. Microfluidic ridges could be fabricated with dimensions as small as 20 μm high × 640 μm wide. Minimum valley dimensions were 30 μm wide × 130 μm wide. An acetone vapor bath was used to smooth acrylonitrile-butadiene-styrene (ABS) surfaces and facilitate bonding of fully enclosed channels. The surfaces of the 3D-printed features were profiled and compared to a similar device fabricated in a glass substrate. Stable stream profiles were obtained in a 3D-printed μFFE device. Separations of fluorescent dyes in the 3D-printed device and its glass counterpart were comparable. A μFFE separation of myoglobin and cytochrome c was also demonstrated on a 3D-printed device. Limits of detection for rhodamine 110 were determined to be 2 and 0.3 nM for the 3D-printed and glass devices, respectively.

  13. 3D Printed Microscope for Mobile Devices that Cost Pennies

    ScienceCinema

    Erikson, Rebecca; Baird, Cheryl; Hutchinson, Janine

    2016-07-12

    Scientists at PNNL have designed a 3D-printable microscope for mobile devices using pennies worth of plastic and glass materials. The microscope has a wide range of uses, from education to in-the-field science.

  14. 3D Printed Microscope for Mobile Devices that Cost Pennies

    SciTech Connect

    Erikson, Rebecca; Baird, Cheryl; Hutchinson, Janine

    2014-09-15

    Scientists at PNNL have designed a 3D-printable microscope for mobile devices using pennies worth of plastic and glass materials. The microscope has a wide range of uses, from education to in-the-field science.

  15. 3D scanning Hall probe microscopy with 700 nm resolution

    NASA Astrophysics Data System (ADS)

    Dede, M.; Akram, R.; Oral, A.

    2016-10-01

    In this report, we present a three dimensional (3D) imaging of magnetic field vector B → (x,y,z) emanating from the magnetic material surfaces using a scanning Hall probe microscopy (3D-SHPM) down to a 700 nm spatial resolution. The Hall probe is used to measure Bz(x,y) on the specimen surface at different heights with the step size of Δz = 250 nm, as we move away from the surface in z direction, until the field decays to zero. These set of images are then used to get ∂Bz(x,y)/∂x and ∂Bz(x,y)/∂y at different z by numerical differentiation. Using the Maxwell's equations in the source free region, Bx(x,y) and By(x,y) can be calculated by integrating ∂Bz(x,y)/∂x and ∂Bz(x,y)/∂y in the z direction. Alternatively, the gradients can also be measured in the Hall gradiometer configuration directly. The operation of the 3D-SHPM is demonstrated by imaging Bx(x,y), By(x,y) and Bz(x,y) on a hard disk specimen at a 700 nm resolution, using both of these methods at 77 K. The system is capable of operating from 300 K down to 4 K range.

  16. An omnidirectional 3D sensor with line laser scanning

    NASA Astrophysics Data System (ADS)

    Xu, Jing; Gao, Bingtuan; Liu, Chuande; Wang, Peng; Gao, Shuanglei

    2016-09-01

    An active omnidirectional vision owns the advantages of the wide field of view (FOV) imaging, resulting in an entire 3D environment scene, which is promising in the field of robot navigation. However, the existing omnidirectional vision sensors based on line laser can measure points only located on the optical plane of the line laser beam, resulting in the low-resolution reconstruction. Whereas, to improve resolution, some other omnidirectional vision sensors with the capability of projecting 2D encode pattern from projector and curved mirror. However, the astigmatism property of curve mirror causes the low-accuracy reconstruction. To solve the above problems, a rotating polygon scanning mirror is used to scan the object in the vertical direction so that an entire profile of the observed scene can be obtained at high accuracy, without of astigmatism phenomenon. Then, the proposed method is calibrated by a conventional 2D checkerboard plate. The experimental results show that the measurement error of the 3D omnidirectional sensor is approximately 1 mm. Moreover, the reconstruction of objects with different shapes based on the developed sensor is also verified.

  17. Experiments on terahertz 3D scanning microscopic imaging

    NASA Astrophysics Data System (ADS)

    Zhou, Yi; Li, Qi

    2016-10-01

    Compared with the visible light and infrared, terahertz (THz) radiation can penetrate nonpolar and nonmetallic materials. There are many studies on the THz coaxial transmission confocal microscopy currently. But few researches on the THz dual-axis reflective confocal microscopy were reported. In this paper, we utilized a dual-axis reflective confocal scanning microscope working at 2.52 THz. In contrast with the THz coaxial transmission confocal microscope, the microscope adopted in this paper can attain higher axial resolution at the expense of reduced lateral resolution, revealing more satisfying 3D imaging capability. Objects such as Chinese characters "Zhong-Hua" written in paper with a pencil and a combined sheet metal which has three layers were scanned. The experimental results indicate that the system can extract two Chinese characters "Zhong," "Hua" or three layers of the combined sheet metal. It can be predicted that the microscope can be applied to biology, medicine and other fields in the future due to its favorable 3D imaging capability.

  18. Automating laser scanning of 3D surfaces for reverse engineering

    NASA Astrophysics Data System (ADS)

    Chan, Vincent H.; Bradley, Colin H.; Vickers, Geoffrey W.

    1997-12-01

    Application of current 3-D laser scanning systems to reverse engineering is limited by two obstacles. The meticulous guidance of the laser scanner over the surface of the object being scanned and the segmentation of the cloud data which is collected by the laser scanner. Presently, both obstacles are being manually solved. The guidance of the laser scanning sensor at the correct surface to sensor distance is dependent on operator judgement and the segmentation of the collected data is reliant on the user to manually define surface boundaries on a computer screen. By applying a 2-D CCD camera, both of these problems can be resolved. Depth information on the location of the object surface can be derived from a pair of stereo images from the CCD camera. Using this depth information, the scanner path can be automatically calculated. Segmentation of the object surface can be accomplished by employing a Kohonen neural network into the CCD image. Successful segmentation of the image is conditional on the locations selected to start neural nodes as well as the prevention of the neuron connectors from bleeding onto neighboring patches. Thus the CCD camera allows for the automatic path planning of the laser scanner as well as the segmentation of the surface into patches defined along its natural boundaries.

  19. Device level 3D characterization using PeakForce AFM

    NASA Astrophysics Data System (ADS)

    Timoney, Padraig; Zhang, Xiaoxiao; Vaid, Alok; Hand, Sean; Osborne, Jason; Milligan, Eric; Feinstein, Adam

    2016-03-01

    Traditional metrology solutions face a range of challenges at the 1X node such as three dimensional (3D) measurement capabilities, shrinking overlay and critical dimension (CD) error budgets driven by multi-patterning and via in trench CD measurements. With advent of advanced technology nodes and 3D processing, an increasing need is emerging for in-die metrology including across-structure and structure-to-structure characterization. A myriad of work has emerged in the past few years intending to address these challenges from various aspects; in-die OCD with reduced spot size and tilt beam on traditional critical dimension scanning electron microscopy (CDSEM) for height measurements. This paper explores the latest capability offered by PeakForceTM Tapping Atomic Force Microscopy (PFT-AFM). The use of traditional harmonic tapping mode for scanning high aspect ratio, and complex "3D" wafer structures, results in limited depth probing capability as well as excessive tip wear. These limitations arise due to the large tip-sample interaction volume in such confined spaces. PeakForce Tapping eliminates these limitations through direct real time control of the tip-sample interaction contact force. The ability of PeakForce to measure, and respond directly to tip- sample interaction forces results in more detailed feature resolution, reduced tip wear, and improved depth capability. In this work, the PFT-AFM tool was applied for multiple applications, including the 14nm fin and replacement metal gate (RMG) applications outlined below. Results from DOE wafers, detailed measurement precision studies and correlation to reference metrology are presented for validation of this methodology. With the fin application, precision of 0.3nm is demonstrated by measuring 5 dies with 10 consecutive runs. Capability to resolve within-die and localized within-macro height variation is also demonstrated. Results obtained from the fin measurements support the increasing trend that measurements

  20. Whole-body 3D scanner and scan data report

    NASA Astrophysics Data System (ADS)

    Addleman, Stephen R.

    1997-03-01

    With the first whole-body 3D scanner now available the next adventure confronting the user is what to do with all of the data. While the system was built for anthropologists, it has created interest among users from a wide variety of fields. Users with applications in the fields of anthropology, costume design, garment design, entertainment, VR and gaming have a need for the data in formats unique to their fields. Data from the scanner is being converted to solid models for art and design and NURBS for computer graphics applications. Motion capture has made scan data move and dance. The scanner has created a need for advanced application software just as other scanners have in the past.

  1. The use of 3D surface scanning for the measurement and assessment of the human foot

    PubMed Central

    2010-01-01

    Background A number of surface scanning systems with the ability to quickly and easily obtain 3D digital representations of the foot are now commercially available. This review aims to present a summary of the reported use of these technologies in footwear development, the design of customised orthotics, and investigations for other ergonomic purposes related to the foot. Methods The PubMed and ScienceDirect databases were searched. Reference lists and experts in the field were also consulted to identify additional articles. Studies in English which had 3D surface scanning of the foot as an integral element of their protocol were included in the review. Results Thirty-eight articles meeting the search criteria were included. Advantages and disadvantages of using 3D surface scanning systems are highlighted. A meta-analysis of studies using scanners to investigate the changes in foot dimensions during varying levels of weight bearing was carried out. Conclusions Modern 3D surface scanning systems can obtain accurate and repeatable digital representations of the foot shape and have been successfully used in medical, ergonomic and footwear development applications. The increasing affordability of these systems presents opportunities for researchers investigating the foot and for manufacturers of foot related apparel and devices, particularly those interested in producing items that are customised to the individual. Suggestions are made for future areas of research and for the standardization of the protocols used to produce foot scans. PMID:20815914

  2. 3D Printed Graphene Based Energy Storage Devices.

    PubMed

    Foster, Christopher W; Down, Michael P; Zhang, Yan; Ji, Xiaobo; Rowley-Neale, Samuel J; Smith, Graham C; Kelly, Peter J; Banks, Craig E

    2017-03-03

    3D printing technology provides a unique platform for rapid prototyping of numerous applications due to its ability to produce low cost 3D printed platforms. Herein, a graphene-based polylactic acid filament (graphene/PLA) has been 3D printed to fabricate a range of 3D disc electrode (3DE) configurations using a conventional RepRap fused deposition moulding (FDM) 3D printer, which requires no further modification/ex-situ curing step. To provide proof-of-concept, these 3D printed electrode architectures are characterised both electrochemically and physicochemically and are advantageously applied as freestanding anodes within Li-ion batteries and as solid-state supercapacitors. These freestanding anodes neglect the requirement for a current collector, thus offering a simplistic and cheaper alternative to traditional Li-ion based setups. Additionally, the ability of these devices' to electrochemically produce hydrogen via the hydrogen evolution reaction (HER) as an alternative to currently utilised platinum based electrodes (with in electrolysers) is also performed. The 3DE demonstrates an unexpectedly high catalytic activity towards the HER (-0.46 V vs. SCE) upon the 1000th cycle, such potential is the closest observed to the desired value of platinum at (-0.25 V vs. SCE). We subsequently suggest that 3D printing of graphene-based conductive filaments allows for the simple fabrication of energy storage devices with bespoke and conceptual designs to be realised.

  3. 3D body scanning technology for fashion and apparel industry

    NASA Astrophysics Data System (ADS)

    D'Apuzzo, Nicola

    2007-01-01

    This paper presents an overview of 3D body scanning technologies with applications to the fashion and apparel industry. Complete systems for the digitization of the human body exist since more than fifteen years. One of the main users of this technology with application in the textile field was the military industry. In fact, body scanning technology is being successfully employed since many years in military bases for a fast selection of the correct size of uniforms for the entire staff. Complete solutions were especially developed for this field of application. Many different research projects were issued for the exploitation of the same technology in the commercial field. Experiments were performed and start-up projects are to time running in different parts of the world by installing full body scanning systems in various locations such as shopping malls, boutiques or dedicated scanning centers. Everything is actually ready to be exploited and all the required hardware, software and solutions are available: full body scanning systems, software for the automatic and reliable extraction of body measurements, e-kiosk and web solutions for the presentation of garments, high-end and low-end virtual-try-on systems. However, complete solutions in this area have still not yet found the expected commercial success. Today, with the on-going large cost reduction given by the appearance of new competitors, methods for digitization of the human body becomes more interesting for the fashion and apparel industry. Therefore, a large expansion of these technologies is expected in the near future. To date, different methods are used commercially for the measurement of the human body. These can be divided into three major distinguished groups: laser-scanning, projection of light patterns, combination modeling and image processing. The different solutions have strengths and weaknesses that profile their suitability for specific applications. This paper gives an overview of their

  4. 3D Printed Graphene Based Energy Storage Devices

    PubMed Central

    Foster, Christopher W.; Down, Michael P.; Zhang, Yan; Ji, Xiaobo; Rowley-Neale, Samuel J.; Smith, Graham C.; Kelly, Peter J.; Banks, Craig E.

    2017-01-01

    3D printing technology provides a unique platform for rapid prototyping of numerous applications due to its ability to produce low cost 3D printed platforms. Herein, a graphene-based polylactic acid filament (graphene/PLA) has been 3D printed to fabricate a range of 3D disc electrode (3DE) configurations using a conventional RepRap fused deposition moulding (FDM) 3D printer, which requires no further modification/ex-situ curing step. To provide proof-of-concept, these 3D printed electrode architectures are characterised both electrochemically and physicochemically and are advantageously applied as freestanding anodes within Li-ion batteries and as solid-state supercapacitors. These freestanding anodes neglect the requirement for a current collector, thus offering a simplistic and cheaper alternative to traditional Li-ion based setups. Additionally, the ability of these devices’ to electrochemically produce hydrogen via the hydrogen evolution reaction (HER) as an alternative to currently utilised platinum based electrodes (with in electrolysers) is also performed. The 3DE demonstrates an unexpectedly high catalytic activity towards the HER (−0.46 V vs. SCE) upon the 1000th cycle, such potential is the closest observed to the desired value of platinum at (−0.25 V vs. SCE). We subsequently suggest that 3D printing of graphene-based conductive filaments allows for the simple fabrication of energy storage devices with bespoke and conceptual designs to be realised. PMID:28256602

  5. 3D Printed Graphene Based Energy Storage Devices

    NASA Astrophysics Data System (ADS)

    Foster, Christopher W.; Down, Michael P.; Zhang, Yan; Ji, Xiaobo; Rowley-Neale, Samuel J.; Smith, Graham C.; Kelly, Peter J.; Banks, Craig E.

    2017-03-01

    3D printing technology provides a unique platform for rapid prototyping of numerous applications due to its ability to produce low cost 3D printed platforms. Herein, a graphene-based polylactic acid filament (graphene/PLA) has been 3D printed to fabricate a range of 3D disc electrode (3DE) configurations using a conventional RepRap fused deposition moulding (FDM) 3D printer, which requires no further modification/ex-situ curing step. To provide proof-of-concept, these 3D printed electrode architectures are characterised both electrochemically and physicochemically and are advantageously applied as freestanding anodes within Li-ion batteries and as solid-state supercapacitors. These freestanding anodes neglect the requirement for a current collector, thus offering a simplistic and cheaper alternative to traditional Li-ion based setups. Additionally, the ability of these devices’ to electrochemically produce hydrogen via the hydrogen evolution reaction (HER) as an alternative to currently utilised platinum based electrodes (with in electrolysers) is also performed. The 3DE demonstrates an unexpectedly high catalytic activity towards the HER (‑0.46 V vs. SCE) upon the 1000th cycle, such potential is the closest observed to the desired value of platinum at (‑0.25 V vs. SCE). We subsequently suggest that 3D printing of graphene-based conductive filaments allows for the simple fabrication of energy storage devices with bespoke and conceptual designs to be realised.

  6. Using Adhesive Patterning to Construct 3D Paper Microfluidic Devices.

    PubMed

    Kalish, Brent; Tsutsui, Hideaki

    2016-04-01

    We demonstrate the use of patterned aerosol adhesives to construct both planar and nonplanar 3D paper microfluidic devices. By spraying an aerosol adhesive through a metal stencil, the overall amount of adhesive used in assembling paper microfluidic devices can be significantly reduced. We show on a simple 4-layer planar paper microfluidic device that the optimal adhesive application technique and device construction style depends heavily on desired performance characteristics. By moderately increasing the overall area of a device, it is possible to dramatically decrease the wicking time and increase device success rates while also reducing the amount of adhesive required to keep the device together. Such adhesive application also causes the adhesive to form semi-permanent bonds instead of permanent bonds between paper layers, enabling single-use devices to be non-destructively disassembled after use. Nonplanar 3D origami devices also benefit from the semi-permanent bonds during folding, as it reduces the likelihood that unrelated faces may accidently stick together. Like planar devices, nonplanar structures see reduced wicking times with patterned adhesive application vs uniformly applied adhesive.

  7. Effects of scanning orientation on outlier formation in 3D laser scanning of reflective surfaces

    NASA Astrophysics Data System (ADS)

    Wang, Yutao; Feng, Hsi-Yung

    2016-06-01

    Inspecting objects with reflective surfaces using 3D laser scanning is a demanded but challenging part inspection task due to undesirable specular reflections, which produce extensive outliers in the scanned point cloud. These outliers need to be removed in order to alleviate subsequent data processing issues. Many existing automatic outlier removal methods do not detect outliers according to the outlier formation properties. As a result, these methods only offer limited capabilities in removing extensive and complex outliers from scanning objects with reflective surfaces. This paper reports an empirical study which experimentally investigates the outlier formation characteristics in relation to the scanning orientation of the laser probe. The objective is to characterize the scanning orientation effects on outlier formation in order to facilitate the development of an effective outlier detection and removal method. Such an experimental investigation was hardly done before. It has been found in this work that scanning orientation can directly affect outlier extensity and occurrence in 3D laser scanning. A general guidance on proper scan path planning can then be provided with an aim to reduce the occurrence of outliers. Further, the observed dependency of outlier formation on scanning orientation can be exploited to facilitate effective and automatic outlier detection and removal.

  8. From Microscale Devices to 3D Printing: Advances in Fabrication of 3D Cardiovascular Tissues.

    PubMed

    Borovjagin, Anton V; Ogle, Brenda M; Berry, Joel L; Zhang, Jianyi

    2017-01-06

    Current strategies for engineering cardiovascular cells and tissues have yielded a variety of sophisticated tools for studying disease mechanisms, for development of drug therapies, and for fabrication of tissue equivalents that may have application in future clinical use. These efforts are motivated by the need to extend traditional 2-dimensional (2D) cell culture systems into 3D to more accurately replicate in vivo cell and tissue function of cardiovascular structures. Developments in microscale devices and bioprinted 3D tissues are beginning to supplant traditional 2D cell cultures and preclinical animal studies that have historically been the standard for drug and tissue development. These new approaches lend themselves to patient-specific diagnostics, therapeutics, and tissue regeneration. The emergence of these technologies also carries technical challenges to be met before traditional cell culture and animal testing become obsolete. Successful development and validation of 3D human tissue constructs will provide powerful new paradigms for more cost effective and timely translation of cardiovascular tissue equivalents.

  9. Diamond Pixel Detectors and 3D Diamond Devices

    NASA Astrophysics Data System (ADS)

    Venturi, N.

    2016-12-01

    Results from detectors of poly-crystalline chemical vapour deposited (pCVD) diamond are presented. These include the first analysis of data of the ATLAS Diamond Beam Monitor (DBM). The DBM module consists of pCVD diamond sensors instrumented with pixellated FE-I4 front-end electronics. Six diamond telescopes, each with three modules, are placed symmetrically around the ATLAS interaction point. The DBM tracking capabilities allow it to discriminate between particles coming from the interaction point and background particles passing through the ATLAS detector. Also, analysis of test beam data of pCVD DBM modules are presented. A new low threshold tuning algorithm based on noise occupancy was developed which increases the DBM module signal to noise ratio significantly. Finally first results from prototypes of a novel detector using pCVD diamond and resistive electrodes in the bulk, forming a 3D diamond device, are discussed. 3D devices based on pCVD diamond were successfully tested with test beams at CERN. The measured charge is compared to that of a strip detector mounted on the same pCVD diamond showing that the 3D device collects significantly more charge than the planar device.

  10. Automated 3D reconstruction of interiors with multiple scan views

    NASA Astrophysics Data System (ADS)

    Sequeira, Vitor; Ng, Kia C.; Wolfart, Erik; Goncalves, Joao G. M.; Hogg, David C.

    1998-12-01

    This paper presents two integrated solutions for realistic 3D model acquisition and reconstruction; an early prototype, in the form of a push trolley, and a later prototype in the form of an autonomous robot. The systems encompass all hardware and software required, from laser and video data acquisition, processing and output of texture-mapped 3D models in VRML format, to batteries for power supply and wireless network communications. The autonomous version is also equipped with a mobile platform and other sensors for the purpose of automatic navigation. The applications for such a system range from real estate and tourism (e.g., showing a 3D computer model of a property to a potential buyer or tenant) or as tool for content creation (e.g., creating 3D models of heritage buildings or producing broadcast quality virtual studios). The system can also be used in industrial environments as a reverse engineering tool to update the design of a plant, or as a 3D photo-archive for insurance purposes. The system is Internet compatible: the photo-realistic models can be accessed via the Internet and manipulated interactively in 3D using a common Web browser with a VRML plug-in. Further information and example reconstructed models are available on- line via the RESOLV web-page at http://www.scs.leeds.ac.uk/resolv/.

  11. 3D thermoplastic elastomer microfluidic devices for biological probe immobilization.

    PubMed

    Brassard, Daniel; Clime, Liviu; Li, Kebin; Geissler, Matthias; Miville-Godin, Caroline; Roy, Emmanuel; Veres, Teodor

    2011-12-07

    Microfluidics has emerged as a valuable tool for the high-resolution patterning of biological probes on solid supports. Yet, its widespread adoption as a universal biological immobilization tool is still limited by several technical challenges, particularly for the patterning of isolated spots using three-dimensional (3D) channel networks. A key limitation arises from the difficulties to adapt the techniques and materials typically used in prototyping to low-cost mass-production. In this paper, we present the fabrication of thin thermoplastic elastomer membranes with microscopic through-holes using a hot-embossing process that is compatible with high-throughput manufacturing. The membranes provide the basis for the fabrication of highly integrated 3D microfluidic devices with a footprint of only 1 × 1 cm(2). When placed on a solid support, the device allows for the immobilization of up to 96 different probes in the form of a 10 × 10 array comprising isolated spots of 50 × 50 μm(2). The design of the channel network is optimized using 3D simulations based on the Lattice-Boltzmann method to promote capillary action as the sole force distributing the liquid in the device. Finally, we demonstrate the patterning of DNA and protein arrays on hard thermoplastic substrates yielding spots of excellent definition that prove to be highly specific in subsequent hybridization experiments.

  12. 3D scanning of internal structure in gel engineering materials with visual scanning microscopic light scattering

    NASA Astrophysics Data System (ADS)

    Watanabe, Yosuke; Gong, Jing; Masato, Makino; Kabir, M. Hasnat; Furukawa, Hidemitsu

    2014-04-01

    The 3D printing technology, causing much attention from the beginning of 2013, will be possibly an alternative method to fabricate the biological soft tissues. Recently our group of Yamagata University has developed the world-first 3D Gel Printer to fabricate the complicated gel-materials with high-strength and biocompatibility. However, there are no 3D scanners that collect the data from the internal structure of complicated gel objects such as eye lens. It means that a new system for scanning the internal structure is needed now. In this study, firstly, we have tried to investigate the gel network of synthetic and biological gel with scanning microscopic light scattering (SMILS). We calculated the Young's modulus of synthetic gels with the SMILS and with the tensile test, and precisely compared the results between them. The temperature dependences of the inside structure and the transparency are observed in the pig crystalline lens. The quantitative analysis indicates the importance of the internal structure of real object. Secondary, we show the new system named Gel-scanner that can provide the 2-dimentional data of the internal structure. From examining our findings, the scanning of internal structure will enable us to expect physical properties of the real object. We convince that the gelscanner will play major role in the various fields.

  13. Aerial obstacle detection with 3-D mobile devices.

    PubMed

    Sáez, Juan Manuel; Escolano, Francisco; Lozano, Miguel Angel

    2015-01-01

    In this paper, we present a novel approach for aerial obstacle detection (e.g., branches or awnings) using a 3-D smartphone in the context of the visually impaired (VI) people assistance. This kind of obstacles are especially challenging because they cannot be detected by the walking stick or the guide dog.The algorithm captures the 3-D data of the scene through stereo vision. To our knowledge, this is the first work that presents a technology able to obtain real 3-D measures with smartphones in real time. The orientation sensors of the device (magnetometer and accelerometer) are used to approximate the walking direction of the user, in order to look for the obstacles only in such a direction. The obtained 3-D data are compressed and then linearized for detecting the potential obstacles. Potential obstacles are tracked in order to accumulate enough evidence to alert the user only when a real obstacle is found.In the experimental section, we show the results of the algorithm in several situations using real data and helped by VI users.

  14. The use of 3D scanning for sporting applications

    NASA Astrophysics Data System (ADS)

    Friel, Kevin; Ajjimaporn, Pann; Straub, Jeremy; Kerlin, Scott

    2015-05-01

    This paper describes the process and research that went into creating a set of 3D models to characterize a golf swing. The purpose of this work is to illustrate how a 3D scanner could be used for assessing athlete performance in sporting applications. In this case, introductory work has been performed to show how the scanner could be used to show the errors a golfer made in a swing. Multiple factors must be taken into account when assessing golfers' swings including the position and movement of the golfer's hands, arms, and foot placement as well as the position of the club head and shaft of the golf club.

  15. Research on 3-D device for infrared temperature detection

    NASA Astrophysics Data System (ADS)

    Chen, Shuxin; Jiang, Shaohua; Hou, Jie; Chen, Shuwang

    2007-12-01

    In a certain field, it is important to measure temperature information in variable direction at the same time. However, there are few instruments to accomplish the function now. To implement the measure in 3 dimensions, an experimental table of temperature detection by infrared is designed. It is the integration of detection, control and monitor. The infrared device in the table can detect and measure temperature in real time, and the three dimension electric motional device can adjust the detection distance by the user. The mechanical bar for displacement is controlled by a circuit with the control button. The infrared temperature sensor is fixed on the bar, so it can move along with the bar controlled by the circuit. The method of temperature detection is untouched, so it can detect small object and its tiny variable temperature, which can not be detected by the thermometer or the electronic temperature sensor. In terms of the 3-D parallel motion control, the device can implement temperature measurement in variable directions. According to the results of the temperature values, the 3-D temperature distributed curve can be described. By using of the detection device, temperature of some special objects can be detected, such as the live anatomical animal, small sensor, nondestructive object, and so on.

  16. Engineering-Aligned 3D Neural Circuit in Microfluidic Device.

    PubMed

    Bang, Seokyoung; Na, Sangcheol; Jang, Jae Myung; Kim, Jinhyun; Jeon, Noo Li

    2016-01-07

    The brain is one of the most important and complex organs in the human body. Although various neural network models have been proposed for in vitro 3D neuronal networks, it has been difficult to mimic functional and structural complexity of the in vitro neural circuit. Here, a microfluidic model of a simplified 3D neural circuit is reported. First, the microfluidic device is filled with Matrigel and continuous flow is delivered across the device during gelation. The fluidic flow aligns the extracellular matrix (ECM) components along the flow direction. Following the alignment of ECM fibers, neurites of primary rat cortical neurons are grown into the Matrigel at the average speed of 250 μm d(-1) and form axon bundles approximately 1500 μm in length at 6 days in vitro (DIV). Additionally, neural networks are developed from presynaptic to postsynaptic neurons at 14 DIV. The establishment of aligned 3D neural circuits is confirmed with the immunostaining of PSD-95 and synaptophysin and the observation of calcium signal transmission.

  17. Combining laser scan and photogrammetry for 3D object modeling using a single digital camera

    NASA Astrophysics Data System (ADS)

    Xiong, Hanwei; Zhang, Hong; Zhang, Xiangwei

    2009-07-01

    In the fields of industrial design, artistic design and heritage conservation, physical objects are usually digitalized by reverse engineering through some 3D scanning methods. Laser scan and photogrammetry are two main methods to be used. For laser scan, a video camera and a laser source are necessary, and for photogrammetry, a digital still camera with high resolution pixels is indispensable. In some 3D modeling tasks, two methods are often integrated to get satisfactory results. Although many research works have been done on how to combine the results of the two methods, no work has been reported to design an integrated device at low cost. In this paper, a new 3D scan system combining laser scan and photogrammetry using a single consumer digital camera is proposed. Nowadays there are many consumer digital cameras, such as Canon EOS 5D Mark II, they usually have features of more than 10M pixels still photo recording and full 1080p HD movie recording, so a integrated scan system can be designed using such a camera. A square plate glued with coded marks is used to place the 3d objects, and two straight wood rulers also glued with coded marks can be laid on the plate freely. In the photogrammetry module, the coded marks on the plate make up a world coordinate and can be used as control network to calibrate the camera, and the planes of two rulers can also be determined. The feature points of the object and the rough volume representation from the silhouettes can be obtained in this module. In the laser scan module, a hand-held line laser is used to scan the object, and the two straight rulers are used as reference planes to determine the position of the laser. The laser scan results in dense points cloud which can be aligned together automatically through calibrated camera parameters. The final complete digital model is obtained through a new a patchwise energy functional method by fusion of the feature points, rough volume and the dense points cloud. The design

  18. Determination of Percent Body Fat Using 3D Whole Body Laser Scanning: A Preliminary Investigation

    DTIC Science & Technology

    2006-11-01

    circumferences, 3D whole body laser scans and DEXA scans were performed on fifty-one men and women age 18-62. Mean percent body fat was not statistically...3D whole body laser scan , and DEXA scan to measure individuals during a one hour measurement session. 1 Report Documentation Page Form...underwent a 6 minute whole body DEXA scan using a GE Lunar Prodigy DEXA scanner running software version 7.53. Percent body fat was calculated from the

  19. Mobile 3D laser scanning technology application in the surveying of urban underground rail transit

    NASA Astrophysics Data System (ADS)

    Han, Youmei; Yang, Bogang; Zhen, Yinan

    2016-11-01

    Mobile 3D laser scanning technology is one hot kind of digital earth technology. 3D completion surveying is relative new concept in surveying and mapping. A kind of mobile 3D laser scanning system was developed for the urban underground rail 3D completion surveying. According to the characteristics of underground rail environment and the characters of the mobile laser scanning system, it designed a suitable test scheme to improving the accuracy of this kind of mobile laser scanning system when it worked under no GPS signal environment. Then it completed the application of this technology in the No.15 rail 3D completion surveying. Meanwhile a set of production process was made for the 3D completion surveying based on this kind of mobile 3D laser scanning technology. These products were also proved the efficiency of the new technology in the rail 3D completion surveying. Using mobile 3D laser scanning technology to complete underground rail completion surveying has been the first time in China until now. It can provide a reference for 3D measurement of rail completion surveying or the 3D completion surveying of other areas.

  20. 3D print of polymer bonded rare-earth magnets, and 3D magnetic field scanning with an end-user 3D printer

    NASA Astrophysics Data System (ADS)

    Huber, C.; Abert, C.; Bruckner, F.; Groenefeld, M.; Muthsam, O.; Schuschnigg, S.; Sirak, K.; Thanhoffer, R.; Teliban, I.; Vogler, C.; Windl, R.; Suess, D.

    2016-10-01

    3D print is a recently developed technique, for single-unit production, and for structures that have been impossible to build previously. The current work presents a method to 3D print polymer bonded isotropic hard magnets with a low-cost, end-user 3D printer. Commercially available isotropic NdFeB powder inside a PA11 matrix is characterized, and prepared for the printing process. An example of a printed magnet with a complex shape that was designed to generate a specific stray field is presented, and compared with finite element simulation solving the macroscopic Maxwell equations. For magnetic characterization, and comparing 3D printed structures with injection molded parts, hysteresis measurements are performed. To measure the stray field outside the magnet, the printer is upgraded to a 3D magnetic flux density measurement system. To skip an elaborate adjusting of the sensor, a simulation is used to calibrate the angles, sensitivity, and the offset of the sensor. With this setup, a measurement resolution of 0.05 mm along the z-axes is achievable. The effectiveness of our calibration method is shown. With our setup, we are able to print polymer bonded magnetic systems with the freedom of having a specific complex shape with locally tailored magnetic properties. The 3D scanning setup is easy to mount, and with our calibration method we are able to get accurate measuring results of the stray field.

  1. Grammar-based Automatic 3D Model Reconstruction from Terrestrial Laser Scanning Data

    NASA Astrophysics Data System (ADS)

    Yu, Q.; Helmholz, P.; Belton, D.; West, G.

    2014-04-01

    The automatic reconstruction of 3D buildings has been an important research topic during the last years. In this paper, a novel method is proposed to automatically reconstruct the 3D building models from segmented data based on pre-defined formal grammar and rules. Such segmented data can be extracted e.g. from terrestrial or mobile laser scanning devices. Two steps are considered in detail. The first step is to transform the segmented data into 3D shapes, for instance using the DXF (Drawing Exchange Format) format which is a CAD data file format used for data interchange between AutoCAD and other program. Second, we develop a formal grammar to describe the building model structure and integrate the pre-defined grammars into the reconstruction process. Depending on the different segmented data, the selected grammar and rules are applied to drive the reconstruction process in an automatic manner. Compared with other existing approaches, our proposed method allows the model reconstruction directly from 3D shapes and takes the whole building into account.

  2. A fast scanning probe for D3-D

    NASA Astrophysics Data System (ADS)

    Watkins, J. G.; Salmonson, J.; Doerner, R.; Lehmer, R.; Moyer, R.; Schmitz, L.; Hill, D. N.

    A fast reciprocating probe was developed for D3-D which can penetrate the separatrix during H - mode with up to 5MW of NBI heating. The probe was designed to carry various sensor tips into the scrape-off layer at a velocity of 3 m/sec and dwell motionless for a programmed period of time. The driving force is provided by a pneumatic cylinder charged with helium to facilitate greater mass flow. The first series of experiments were done using a Langmuir probe head with 5 graphite tips to measure radial profiles of n(sub e), T(sub e), phi(sub f), (n tilde)(sub e), and (phi tilde)(sub f). The amplitude and phase of the fluctuating quantities are measured by using specially constructed vacuum compatible 5 kV coaxial transmission lines which allow us to extend the measurements into the MHz range. TTZ ceramic bearings and fast stroke bellows were also specially designed for the D3-D probe. Initial measurements will be presented.

  3. Real-time 3-D ultrasound scan conversion using a multicore processor.

    PubMed

    Zhuang, Bo; Shamdasani, Vijay; Sikdar, Siddhartha; Managuli, Ravi; Kim, Yongmin

    2009-07-01

    Real-time 3-D ultrasound scan conversion (SC) in software has not been practical due to its high computation and I/O data handling requirements. In this paper, we describe software-based 3-D SC with high volume rates using a multicore processor, Cell. We have implemented both 3-D SC approaches: 1) the separable 3-D SC where two 2-D coordinate transformations in orthogonal planes are performed in sequence and 2) the direct 3-D SC where the coordinate transformation is directly handled in 3-D. One Cell processor can scan-convert a 192 x 192 x 192 16-bit volume at 87.8 volumes/s with the separable 3-D SC algorithm and 28 volumes/s with the direct 3-D SC algorithm.

  4. MEMS-BASED 3D CONFOCAL SCANNING MICROENDOSCOPE USING MEMS SCANNERS FOR BOTH LATERAL AND AXIAL SCAN

    PubMed Central

    Liu, Lin; Wang, Erkang; Zhang, Xiaoyang; Liang, Wenxuan; Li, Xingde; Xie, Huikai

    2014-01-01

    A fiber-optic 3D confocal scanning microendoscope employing MEMS scanners for both lateral and axial scan was designed and constructed. The MEMS 3D scan engine achieved a lateral scan range of over ± 26° with a 2D MEMS scanning micromirror and a depth scan of over 400 μm with a 1D MEMS tunable microlens. The lateral resolution and axial resolution of this system were experimentally measured as 1.0 μm and 7.0 μm, respectively. 2D and 3D confocal reflectance images of micro-patterns, micro-particles, onion skins and acute rat brain tissue were obtained by this MEMS-based 3D confocal scanning microendoscope. PMID:25013304

  5. Recent progress in printed 2/3D electronic devices

    NASA Astrophysics Data System (ADS)

    Klug, Andreas; Patter, Paul; Popovic, Karl; Blümel, Alexander; Sax, Stefan; Lenz, Martin; Glushko, Oleksandr; Cordill, Megan J.; List-Kratochvil, Emil J. W.

    2015-09-01

    New, energy-saving, efficient and cost-effective processing technologies such as 2D and 3D inkjet printing (IJP) for the production and integration of intelligent components will be opening up very interesting possibilities for industrial applications of molecular materials in the near future. Beyond the use of home and office based printers, "inkjet printing technology" allows for the additive structured deposition of photonic and electronic materials on a wide variety of substrates such as textiles, plastics, wood, stone, tiles or cardboard. Great interest also exists in applying IJP in industrial manufacturing such as the manufacturing of PCBs, of solar cells, printed organic electronics and medical products. In all these cases inkjet printing is a flexible (digital), additive, selective and cost-efficient material deposition method. Due to these advantages, there is the prospect that currently used standard patterning processes can be replaced through this innovative material deposition technique. A main issue in this research area is the formulation of novel functional inks or the adaptation of commercially available inks for specific industrial applications and/or processes. In this contribution we report on the design, realization and characterization of novel active and passive inkjet printed electronic devices including circuitry and sensors based on metal nanoparticle ink formulations and the heterogeneous integration into 2/3D printed demonstrators. The main emphasis of this paper will be on how to convert scientific inkjet knowledge into industrially relevant processes and applications.

  6. Determining the 3-D structure and motion of objects using a scanning laser range sensor

    NASA Astrophysics Data System (ADS)

    Nandhakumar, N.; Smith, Philip W.

    1993-12-01

    In order for the EVAHR robot to autonomously track and grasp objects, its vision system must be able to determine the 3-D structure and motion of an object from a sequence of sensory images. This task is accomplished by the use of a laser radar range sensor which provides dense range maps of the scene. Unfortunately, the currently available laser radar range cameras use a sequential scanning approach which complicates image analysis. Although many algorithms have been developed for recognizing objects from range images, none are suited for use with single beam, scanning, time-of-flight sensors because all previous algorithms assume instantaneous acquisition of the entire image. This assumption is invalid since the EVAHR robot is equipped with a sequential scanning laser range sensor. If an object is moving while being imaged by the device, the apparent structure of the object can be significantly distorted due to the significant non-zero delay time between sampling each image pixel. If an estimate of the motion of the object can be determined, this distortion can be eliminated; but, this leads to the motion-structure paradox - most existing algorithms for 3-D motion estimation use the structure of objects to parameterize their motions. The goal of this research is to design a rigid-body motion recovery technique which overcomes this limitation. The method being developed is an iterative, linear, feature-based approach which uses the non-zero image acquisition time constraint to accurately recover the motion parameters from the distorted structure of the 3-D range maps. Once the motion parameters are determined, the structural distortion in the range images is corrected.

  7. 3D FaceCam: a fast and accurate 3D facial imaging device for biometrics applications

    NASA Astrophysics Data System (ADS)

    Geng, Jason; Zhuang, Ping; May, Patrick; Yi, Steven; Tunnell, David

    2004-08-01

    Human faces are fundamentally three-dimensional (3D) objects, and each face has its unique 3D geometric profile. The 3D geometric features of a human face can be used, together with its 2D texture, for rapid and accurate face recognition purposes. Due to the lack of low-cost and robust 3D sensors and effective 3D facial recognition (FR) algorithms, almost all existing FR systems use 2D face images. Genex has developed 3D solutions that overcome the inherent problems in 2D while also addressing limitations in other 3D alternatives. One important aspect of our solution is a unique 3D camera (the 3D FaceCam) that combines multiple imaging sensors within a single compact device to provide instantaneous, ear-to-ear coverage of a human face. This 3D camera uses three high-resolution CCD sensors and a color encoded pattern projection system. The RGB color information from each pixel is used to compute the range data and generate an accurate 3D surface map. The imaging system uses no moving parts and combines multiple 3D views to provide detailed and complete 3D coverage of the entire face. Images are captured within a fraction of a second and full-frame 3D data is produced within a few seconds. This described method provides much better data coverage and accuracy in feature areas with sharp features or details (such as the nose and eyes). Using this 3D data, we have been able to demonstrate that a 3D approach can significantly improve the performance of facial recognition. We have conducted tests in which we have varied the lighting conditions and angle of image acquisition in the "field." These tests have shown that the matching results are significantly improved when enrolling a 3D image rather than a single 2D image. With its 3D solutions, Genex is working toward unlocking the promise of powerful 3D FR and transferring FR from a lab technology into a real-world biometric solution.

  8. Development of a 3D Graphene Electrode Dielectrophoretic Device

    PubMed Central

    Xie, Hongyu; Tewari, Radheshyam; Fukushima, Hiroyuki; Narendra, Jeffri; Heldt, Caryn; King, Julia; Minerick, Adrienne R.

    2014-01-01

    The design and fabrication of a novel 3D electrode microdevice using 50 µm thick graphene paper and 100 µm double sided tape is described. The protocol details the procedures to construct a versatile, reusable, multiple layer, laminated dielectrophoresis chamber. Specifically, six layers of 50 µm x 0.7 cm x 2 cm graphene paper and five layers of double sided tape were alternately stacked together, then clamped to a glass slide. Then a 700 μm diameter micro-well was drilled through the laminated structure using a computer-controlled micro drilling machine. Insulating properties of the tape layer between adjacent graphene layers were assured by resistance tests. Silver conductive epoxy connected alternate layers of graphene paper and formed stable connections between the graphene paper and external copper wire electrodes. The finished device was then clamped and sealed to a glass slide. The electric field gradient was modeled within the multi-layer device. Dielectrophoretic behaviors of 6 μm polystyrene beads were demonstrated in the 1 mm deep micro-well, with medium conductivities ranging from 0.0001 S/m to 1.3 S/m, and applied signal frequencies from 100 Hz to 10 MHz. Negative dielectrophoretic responses were observed in three dimensions over most of the conductivity-frequency space and cross-over frequency values are consistent with previously reported literature values. The device did not prevent AC electroosmosis and electrothermal flows, which occurred in the low and high frequency regions, respectively. The graphene paper utilized in this device is versatile and could subsequently function as a biosensor after dielectrophoretic characterizations are complete. PMID:24998694

  9. State of the art of 3D scanning systems and inspection of textile surfaces

    NASA Astrophysics Data System (ADS)

    Montilla, M.; Orjuela-Vargas, S. A.; Philips, W.

    2014-02-01

    The rapid development of hardware and software in the digital image processing field has boosted research in computer vision for applications in industry. The development of new electronic devices and the tendency to decrease their prices makes possible new developments that few decades ago were possible only in the imagination. This is the case of 3D imaging technology which permits to detect failures in industrial products by inspecting aspects on their 3D surface. In search of an optimal solution for scanning textiles we present in this paper a review of existing techniques for digitizing 3D surfaces. Topographic details of textiles can be obtained by digitizing surfaces using laser line triangulation, phase shifting optical triangulation, projected-light, stereo-vision systems and silhouette analysis. Although we are focused on methods that have been used in the textile industry, we also consider potential mechanisms used for other applications. We discuss the advantages and disadvantages of the evaluated methods and state a summary of potential implementations for the textile industry.

  10. Filtering method for 3D laser scanning point cloud

    NASA Astrophysics Data System (ADS)

    Liu, Da; Wang, Li; Hao, Yuncai; Zhang, Jun

    2015-10-01

    In recent years, with the rapid development of the hardware and software of the three-dimensional model acquisition, three-dimensional laser scanning technology is utilized in various aspects, especially in space exploration. The point cloud filter is very important before using the data. In the paper, considering both the processing quality and computing speed, an improved mean-shift point cloud filter method is proposed. Firstly, by analyze the relevance of the normal vector between the upcoming processing point and the near points, the iterative neighborhood of the mean-shift is selected dynamically, then the high frequency noise is constrained. Secondly, considering the normal vector of the processing point, the normal vector is updated. Finally, updated position is calculated for each point, then each point is moved in the normal vector according to the updated position. The experimental results show that the large features are retained, at the same time, the small sharp features are also existed for different size and shape of objects, so the target feature information is protected precisely. The computational complexity of the proposed method is not high, it can bring high precision results with fast speed, so it is very suitable for space application. It can also be utilized in civil, such as large object measurement, industrial measurement, car navigation etc. In the future, filter with the help of point strength will be further exploited.

  11. High-resolution real-time 3D shape measurement on a portable device

    NASA Astrophysics Data System (ADS)

    Karpinsky, Nikolaus; Hoke, Morgan; Chen, Vincent; Zhang, Song

    2013-09-01

    Recent advances in technology have enabled the acquisition of high-resolution 3D models in real-time though the use of structured light scanning techniques. While these advances are impressive, they require large amounts of computing power, thus being limited to using large desktop computers with high end CPUs and sometimes GPUs. This is undesirable in making high-resolution real-time 3D scanners ubiquitous in our mobile lives. To address this issue, this work describes and demonstrates a real-time 3D scanning system that is realized on a mobile device, namely a laptop computer, which can achieve speeds of 20fps 3D at a resolution of 640x480 per frame. By utilizing a graphics processing unit (GPU) as a multipurpose parallel processor, along with a parallel phase shifting technique, we are able to realize the entire 3D processing pipeline in parallel. To mitigate high speed camera transfer problems, which typically require a dedicated frame grabber, we make use of USB 3.0 along with direct memory access (DMA) to transfer camera images to the GPU. To demonstrate the effectiveness of the technique, we experiment with the scanner on both static geometry of a statue and dynamic geometry of a deforming material sample in front of the system.

  12. Laser Scanning Holographic Lithography for Flexible 3D Fabrication of Multi-Scale Integrated Nano-structures and Optical Biosensors.

    PubMed

    Yuan, Liang Leon; Herman, Peter R

    2016-02-29

    Three-dimensional (3D) periodic nanostructures underpin a promising research direction on the frontiers of nanoscience and technology to generate advanced materials for exploiting novel photonic crystal (PC) and nanofluidic functionalities. However, formation of uniform and defect-free 3D periodic structures over large areas that can further integrate into multifunctional devices has remained a major challenge. Here, we introduce a laser scanning holographic method for 3D exposure in thick photoresist that combines the unique advantages of large area 3D holographic interference lithography (HIL) with the flexible patterning of laser direct writing to form both micro- and nano-structures in a single exposure step. Phase mask interference patterns accumulated over multiple overlapping scans are shown to stitch seamlessly and form uniform 3D nanostructure with beam size scaled to small 200 μm diameter. In this way, laser scanning is presented as a facile means to embed 3D PC structure within microfluidic channels for integration into an optofluidic lab-on-chip, demonstrating a new laser HIL writing approach for creating multi-scale integrated microsystems.

  13. Laser Scanning Holographic Lithography for Flexible 3D Fabrication of Multi-Scale Integrated Nano-structures and Optical Biosensors

    NASA Astrophysics Data System (ADS)

    Yuan, Liang (Leon); Herman, Peter R.

    2016-02-01

    Three-dimensional (3D) periodic nanostructures underpin a promising research direction on the frontiers of nanoscience and technology to generate advanced materials for exploiting novel photonic crystal (PC) and nanofluidic functionalities. However, formation of uniform and defect-free 3D periodic structures over large areas that can further integrate into multifunctional devices has remained a major challenge. Here, we introduce a laser scanning holographic method for 3D exposure in thick photoresist that combines the unique advantages of large area 3D holographic interference lithography (HIL) with the flexible patterning of laser direct writing to form both micro- and nano-structures in a single exposure step. Phase mask interference patterns accumulated over multiple overlapping scans are shown to stitch seamlessly and form uniform 3D nanostructure with beam size scaled to small 200 μm diameter. In this way, laser scanning is presented as a facile means to embed 3D PC structure within microfluidic channels for integration into an optofluidic lab-on-chip, demonstrating a new laser HIL writing approach for creating multi-scale integrated microsystems.

  14. Laser Scanning Holographic Lithography for Flexible 3D Fabrication of Multi-Scale Integrated Nano-structures and Optical Biosensors

    PubMed Central

    Yuan, Liang (Leon); Herman, Peter R.

    2016-01-01

    Three-dimensional (3D) periodic nanostructures underpin a promising research direction on the frontiers of nanoscience and technology to generate advanced materials for exploiting novel photonic crystal (PC) and nanofluidic functionalities. However, formation of uniform and defect-free 3D periodic structures over large areas that can further integrate into multifunctional devices has remained a major challenge. Here, we introduce a laser scanning holographic method for 3D exposure in thick photoresist that combines the unique advantages of large area 3D holographic interference lithography (HIL) with the flexible patterning of laser direct writing to form both micro- and nano-structures in a single exposure step. Phase mask interference patterns accumulated over multiple overlapping scans are shown to stitch seamlessly and form uniform 3D nanostructure with beam size scaled to small 200 μm diameter. In this way, laser scanning is presented as a facile means to embed 3D PC structure within microfluidic channels for integration into an optofluidic lab-on-chip, demonstrating a new laser HIL writing approach for creating multi-scale integrated microsystems. PMID:26922872

  15. Reducing Costs and Increasing Productivity in Ship Maintenance Using Product Lifecycle Management, 3D Laser Scanning and 3D Printing

    DTIC Science & Technology

    2014-03-01

    Advantages ........................................................ 28 7. 3D Printer Usage in the Department of Defense ................. 29 a. Army...28 Figure 17. 3D Printer Forecast (from 3D Systems, 2013) .................................... 29 Figure 18. History...Several companies, including 3D Systems and Stratasys, produce 3D printers for both personal and industrial use. In addition, open source models

  16. 3D site specific sample preparation and analysis of 3D devices (FinFETs) by atom probe tomography.

    PubMed

    Kambham, Ajay Kumar; Kumar, Arul; Gilbert, Matthieu; Vandervorst, Wilfried

    2013-09-01

    With the transition from planar to three-dimensional device architectures such as Fin field-effect-transistors (FinFETs), new metrology approaches are required to meet the needs of semiconductor technology. It is important to characterize the 3D-dopant distributions precisely as their extent, positioning relative to gate edges and absolute concentration determine the device performance in great detail. At present the atom probe has shown its ability to analyze dopant distributions in semiconductor and thin insulating materials with sub-nm 3D-resolution and good dopant sensitivity. However, so far most reports have dealt with planar devices or restricted the measurements to 2D test structures which represent only limited challenges in terms of localization and site specific sample preparation. In this paper we will discuss the methodology to extract the dopant distribution from real 3D-devices such as a 3D-FinFET device, requiring the sample preparation to be carried out at a site specific location with a positioning accuracy ∼50 nm.

  17. 3D microfilter device for viable circulating tumor cell (CTC) enrichment from blood.

    PubMed

    Zheng, Siyang; Lin, Henry K; Lu, Bo; Williams, Anthony; Datar, Ram; Cote, Richard J; Tai, Yu-Chong

    2011-02-01

    Detection of circulating tumor cells has emerged as a promising minimally invasive diagnostic and prognostic tool for patients with metastatic cancers. We report a novel three dimensional microfilter device that can enrich viable circulating tumor cells from blood. This device consists of two layers of parylene membrane with pores and gap precisely defined with photolithography. The positions of the pores are shifted between the top and bottom membranes. The bottom membrane supports captured cells and minimize the stress concentration on cell membrane and sustain cell viability during filtration. Viable cell capture on device was investigated with scanning electron microscopy, confocal microscopy, and immunofluorescent staining using model systems of cultured tumor cells spiked in blood or saline. The paper presents and validates this new 3D microfiltration concept for circulation tumor cell enrichment application. The device provides a highly valuable tool for assessing and characterizing viable enriched circulating tumor cells in both research and clinical settings.

  18. Remote z-scanning with a macroscopic voice coil motor for fast 3D multiphoton laser scanning microscopy

    PubMed Central

    Rupprecht, Peter; Prendergast, Andrew; Wyart, Claire; Friedrich, Rainer W

    2016-01-01

    There is a high demand for 3D multiphoton imaging in neuroscience and other fields but scanning in axial direction presents technical challenges. We developed a focusing technique based on a remote movable mirror that is conjugate to the specimen plane and translated by a voice coil motor. We constructed cost-effective z-scanning modules from off-the-shelf components that can be mounted onto standard multiphoton laser scanning microscopes to extend scan patterns from 2D to 3D. Systems were designed for large objectives and provide high resolution, high speed and a large z-scan range (>300 μm). We used these systems for 3D multiphoton calcium imaging in the adult zebrafish brain and measured odor-evoked activity patterns across >1500 neurons with single-neuron resolution and high signal-to-noise ratio. PMID:27231612

  19. A 3D acquisition system combination of structured-light scanning and shape from silhouette

    NASA Astrophysics Data System (ADS)

    Sun, Changku; Tao, Li; Wang, Peng; He, Li

    2006-05-01

    A robust and accurate three dimensional (3D) acquisition system is presented, which is a combination of structured-light scanning and shape from silhouette. Using common world coordinate system, two groups of point data can be integrated into the final complete 3D model without any integration and registration algorithm. The mathematics model of structured-light scanning is described in detail, and the shape from silhouette algorithm is introduced as well. The complete 3D model of a cup with a handle is obtained successfully by the proposed technique. At last the measurement on a ball bearing is performed, with the measurement precision better than 0.15 mm.

  20. 3D Printing: 3D Printing of Shape Memory Polymers for Flexible Electronic Devices (Adv. Mater. 22/2016).

    PubMed

    Zarek, Matt; Layani, Michael; Cooperstein, Ido; Sachyani, Ela; Cohn, Daniel; Magdassi, Shlomo

    2016-06-01

    On page 4449, D. Cohn, S. Magdassi, and co-workers describe a general and facile method based on 3D printing of methacrylated macromonomers to fabricate shape-memory objects that can be used in flexible and responsive electrical circuits. Such responsive objects can be used in the fabrication of soft robotics, minimal invasive medical devices, sensors, and wearable electronics. The use of 3D printing overcomes the poor processing characteristics of thermosets and enables complex geometries that are not easily accessible by other techniques.

  1. A novel two-axis micromechanical scanning transducer for handheld 3D ultrasound and photoacoustic imaging

    NASA Astrophysics Data System (ADS)

    Huang, Chih-Hsien; Zou, Jun

    2016-03-01

    This paper reports the development of a new two-axis micromechanical scanning transducer for handheld 3D ultrasound imaging. It consists of a miniaturized single-element ultrasound transducer driven by a unique 2-axis liquid-immersible electromagnetic microactuator. With a mechanical scanning frequency of 19.532 Hz and an ultrasound pulse repetition rate of 5 kHz, the scanning transducer was scanned along 60 concentric paths with 256 detection points on each to simulate a physical 2D ultrasound transducer array of 60 × 256 elements. Using the scanning transducer, 3D pulse-echo ultrasound imaging of two silicon discs immersed in water as the imaging target was successfully conducted. The lateral resolution of the 3D ultrasound image was further improved with the synthetic aperture focusing technique (SAFT). The new two-axis micromechanical scanning transducer doesn't require complex and expensive multi-channel data acquisition (DAQ) electronics. Therefore, it could provide a new approach to achieve compact and low-cost 3D ultrasound and photoacoustic imaging systems, especially for handheld operations.

  2. A 3-d laser scanning system and scan data processing method for the monitoring of tunnel deformations

    NASA Astrophysics Data System (ADS)

    Chmelina, Klaus; Jansa, Josef; Hesina, Gerd; Traxler, Christoph

    2012-11-01

    The paper presents the mobile multi-sensor system Orthos Plus for the monitoring and mapping of tunnel walls, a scan data processing method for the evaluation of 3-d tunnel wall displacements from subsequent wall scans and, finally, a virtual reality tool supporting the interpretation of data. The measuring system consists of a 3-d laser scanner, a motorised total station and a digital camera that are integrated on a light metal frame that is installed on a mobile platform. It has been designed to perform tunnel measurements most efficiently and to meet the special requirements of tunnels under construction. The evaluation of 3-d displacements is based on a 3-d matching algorithm that takes advantage of the particular conditions of tunnel (shotcrete) surfaces. The virtual reality tool allows viewing of data in a 3-d virtual reality tunnel model and their animation in time and space in order supports understanding in an optimal way. The measuring system Orthos Plus has been developed in the course of a national research project, the 3-d matching method in the frame of the Austrian Christian Doppler Laboratory Spatial Data from Laser Scanning and Remote Sensing and the VR tool in the Austrian COMET K1 Competence Center VRVis Center (www.vrvis.at).

  3. Process monitor of 3D-device features by using FIB and CD-SEM

    NASA Astrophysics Data System (ADS)

    Kawada, Hiroki; Ikota, Masami; Sakai, Hideo; Torikawa, Shota; Tomimatsu, Satoshi; Onishi, Tsuyoshi

    2016-03-01

    For yield improvement of 3D-device manufacturing, metrology for the variability of individual device-features is on hot issue. Transmission Electron Microscope (TEM) can be used for monitoring the individual cross-section. However, efficiency of process monitoring is limited by the speed of measurement including preparation of lamella sample. In this work we demonstrate speedy 3D-profile measurement of individual line-features without the lamella sampling. For instance, we make a-few-micrometer-wide and 45-degree-descending slope in dense line-features by using Focused Ion Beam (FIB) tool capable of 300mm-wafer. On the descending slope, obliquely cut cross-section of the line features appears. Then, we transfer the wafer to Critical-Dimension Secondary Electron Microscope (CDSEM) to measure the oblique cross-section in normal top-down view. As the descending angle is 45 degrees, the oblique cross-section looks like a cross-section normal to the wafer surface. For every single line-features the 3D dimensions are measured. To the reference metrology of the Scanning TEM (STEM), nanometric linearity and precision are confirmed for the height and the width under the hard mask of the line features. Without cleaving wafer the 60 cells on the wafer can be measured in 3 hours, which allows us of near-line process monitor of in-wafer uniformity.

  4. Angle extended linear MEMS scanning system for 3D laser vision sensor

    NASA Astrophysics Data System (ADS)

    Pang, Yajun; Zhang, Yinxin; Yang, Huaidong; Zhu, Pan; Gai, Ye; Zhao, Jian; Huang, Zhanhua

    2016-09-01

    Scanning system is often considered as the most important part for 3D laser vision sensor. In this paper, we propose a method for the optical system design of angle extended linear MEMS scanning system, which has features of huge scanning degree, small beam divergence angle and small spot size for 3D laser vision sensor. The principle of design and theoretical formulas are derived strictly. With the help of software ZEMAX, a linear scanning optical system based on MEMS has been designed. Results show that the designed system can extend scanning angle from ±8° to ±26.5° with a divergence angle small than 3.5 mr, and the spot size is reduced for 4.545 times.

  5. Alignment of 3-D optical coherence tomography scans to correct eye movement using a particle filtering.

    PubMed

    Xu, Juan; Ishikawa, Hiroshi; Wollstein, Gadi; Kagemann, Larry; Schuman, Joel S

    2012-07-01

    Eye movement artifacts occurring during 3-D optical coherence tomography (OCT) scanning is a well-recognized problem that may adversely affect image analysis and interpretation. A particle filtering algorithm is presented in this paper to correct motion in a 3-D dataset by considering eye movement as a target tracking problem in a dynamic system. The proposed particle filtering algorithm is an independent 3-D alignment approach, which does not rely on any reference image. 3-D OCT data is considered as a dynamic system, while the location of each A-scan is represented by the state space. A particle set is used to approximate the probability density of the state in the dynamic system. The state of the system is updated frame by frame to detect A-scan movement. The proposed method was applied on both simulated data for objective evaluation and experimental data for subjective evaluation. The sensitivity and specificity of the x-movement detection were 98.85% and 99.43%, respectively, in the simulated data. For the experimental data (74 3-D OCT images), all the images were improved after z-alignment, while 81.1% images were improved after x-alignment. The proposed algorithm is an efficient way to align 3-D OCT volume data and correct the eye movement without using references.

  6. Taking advantage of selective change driven processing for 3D scanning.

    PubMed

    Vegara, Francisco; Zuccarello, Pedro; Boluda, Jose A; Pardo, Fernando

    2013-09-27

    This article deals with the application of the principles of SCD (Selective Change Driven) vision to 3D laser scanning. Two experimental sets have been implemented: one with a classical CMOS (Complementary Metal-Oxide Semiconductor) sensor, and the other one with a recently developed CMOS SCD sensor for comparative purposes, both using the technique known as Active Triangulation. An SCD sensor only delivers the pixels that have changed most, ordered by the magnitude of their change since their last readout. The 3D scanning method is based on the systematic search through the entire image to detect pixels that exceed a certain threshold, showing the SCD approach to be ideal for this application. Several experiments for both capturing strategies have been performed to try to find the limitations in high speed acquisition/processing. The classical approach is limited by the sequential array acquisition, as predicted by the Nyquist-Shannon sampling theorem, and this has been experimentally demonstrated in the case of a rotating helix. These limitations are overcome by the SCD 3D scanning prototype achieving a significantly higher performance. The aim of this article is to compare both capturing strategies in terms of performance in the time and frequency domains, so they share all the static characteristics including resolution, 3D scanning method, etc., thus yielding the same 3D reconstruction in static scenes.

  7. Taking Advantage of Selective Change Driven Processing for 3D Scanning

    PubMed Central

    Vegara, Francisco; Zuccarello, Pedro; Boluda, Jose A.; Pardo, Fernando

    2013-01-01

    This article deals with the application of the principles of SCD (Selective Change Driven) vision to 3D laser scanning. Two experimental sets have been implemented: one with a classical CMOS (Complementary Metal-Oxide Semiconductor) sensor, and the other one with a recently developed CMOS SCD sensor for comparative purposes, both using the technique known as Active Triangulation. An SCD sensor only delivers the pixels that have changed most, ordered by the magnitude of their change since their last readout. The 3D scanning method is based on the systematic search through the entire image to detect pixels that exceed a certain threshold, showing the SCD approach to be ideal for this application. Several experiments for both capturing strategies have been performed to try to find the limitations in high speed acquisition/processing. The classical approach is limited by the sequential array acquisition, as predicted by the Nyquist–Shannon sampling theorem, and this has been experimentally demonstrated in the case of a rotating helix. These limitations are overcome by the SCD 3D scanning prototype achieving a significantly higher performance. The aim of this article is to compare both capturing strategies in terms of performance in the time and frequency domains, so they share all the static characteristics including resolution, 3D scanning method, etc., thus yielding the same 3D reconstruction in static scenes. PMID:24084110

  8. Integration of 3D anatomical data obtained by CT imaging and 3D optical scanning for computer aided implant surgery

    PubMed Central

    2011-01-01

    Background A precise placement of dental implants is a crucial step to optimize both prosthetic aspects and functional constraints. In this context, the use of virtual guiding systems has been recognized as a fundamental tool to control the ideal implant position. In particular, complex periodontal surgeries can be performed using preoperative planning based on CT data. The critical point of the procedure relies on the lack of accuracy in transferring CT planning information to surgical field through custom-made stereo-lithographic surgical guides. Methods In this work, a novel methodology is proposed for monitoring loss of accuracy in transferring CT dental information into periodontal surgical field. The methodology is based on integrating 3D data of anatomical (impression and cast) and preoperative (radiographic template) models, obtained by both CT and optical scanning processes. Results A clinical case, relative to a fully edentulous jaw patient, has been used as test case to assess the accuracy of the various steps concurring in manufacturing surgical guides. In particular, a surgical guide has been designed to place implants in the bone structure of the patient. The analysis of the results has allowed the clinician to monitor all the errors, which have been occurring step by step manufacturing the physical templates. Conclusions The use of an optical scanner, which has a higher resolution and accuracy than CT scanning, has demonstrated to be a valid support to control the precision of the various physical models adopted and to point out possible error sources. A case study regarding a fully edentulous patient has confirmed the feasibility of the proposed methodology. PMID:21338504

  9. Integrated Interventional Devices For Real Time 3D Ultrasound Imaging and Therapy

    NASA Astrophysics Data System (ADS)

    Smith, Stephen W.; Lee, Warren; Gentry, Kenneth L.; Pua, Eric C.; Light, Edward D.

    2006-05-01

    Two recent advances have expanded the potential of medical ultrasound: the introduction of real-time 3-D ultrasound imaging with catheter, transesophageal and laparoscopic probes and the development of interventional ultrasound therapeutic systems for focused ultrasound surgery, ablation and ultrasound enhanced drug delivery. This work describes devices combining both technologies. A series of transducer probes have been designed, fabricated and tested including: 1) a 12 French side scanning catheter incorporating a 64 element matrix array for imaging at 5MHz and a piston ablation transducer operating at 10 MHz. 2) a 14 Fr forward-scanning catheter integrating a 112 element 2-D array for imaging at 5 MHz encircled by an ablation annulus operating at 10 MHz. Finite element modeling was then used to simulate catheter annular and linear phased array transducers for ablation. 3) Linear phased array transducers were built to confirm the finite element analysis at 4 and 8 MHz including a mechanically focused 86 element 9 MHz array which transmits an ISPTA of 29.3 W/cm2 and creates a lesion in 2 minutes. 4) 2-D arrays of 504 channels operating at 5 MHz have been developed for transesophageal and laparascopic 3D imaging as well as therapeutic heating. All the devices image the heart anatomy including atria, valves, septa and en face views of the pulmonary veins.

  10. Optimum conditions for high-quality 3D reconstruction in confocal scanning microscopy

    NASA Astrophysics Data System (ADS)

    Kim, Taehoon; Kim, Taejoong; Lee, SeungWoo; Gweon, Dae-Gab; Seo, Jungwoo

    2006-02-01

    Confocal Scanning Microscopy (CSM) is very useful to reconstruct 3D image of Bio-cells and the objects that have specification shape in higher axial and lateral resolution and widely used as measurement instrument. A 3D reconstruction is used to visualize confocal images and consists of following processes. The First process is to get 3D data by collecting a series of images at regular focus intervals (Optical Sectioning). The Second process is to fit a curve to a series of 3D data points each pixel. The Third process is to search height information that has maximum value from curve-fitting. However, because of various systematic errors (NOISE) occurred when collecting the information of images through Optical Sectioning and large peak deviation occurred from curve-fitting error, high quality 3D reconstruction is not expected. Also, it takes much time to 3d Reconstruction by using many 3D data in order to acquire high quality and much cost to improve signal-to-noise (SNR) using a higher power laser. So, we are going to define SNR, peak deviation and the order of curve-fitting as important factors and simulate the relation between the factors in order to find a optimum condition for high quality 3D reconstruction in Confoal Scanning Microscopy. If we use optimum condition obtained by this simulation, using a suitable SNR and the suitable number of data and the suitable n-th order curve-fitting, small peak deviation is expected and then, 3D reconstruction of little better quality is expected. Also, it is expected to save.

  11. Vessel segmentation in 3D spectral OCT scans of the retina

    NASA Astrophysics Data System (ADS)

    Niemeijer, Meindert; Garvin, Mona K.; van Ginneken, Bram; Sonka, Milan; Abràmoff, Michael D.

    2008-03-01

    The latest generation of spectral optical coherence tomography (OCT) scanners is able to image 3D cross-sectional volumes of the retina at a high resolution and high speed. These scans offer a detailed view of the structure of the retina. Automated segmentation of the vessels in these volumes may lead to more objective diagnosis of retinal vascular disease including hypertensive retinopathy, retinopathy of prematurity. Additionally, vessel segmentation can allow color fundus images to be registered to these 3D volumes, possibly leading to a better understanding of the structure and localization of retinal structures and lesions. In this paper we present a method for automatically segmenting the vessels in a 3D OCT volume. First, the retina is automatically segmented into multiple layers, using simultaneous segmentation of their boundary surfaces in 3D. Next, a 2D projection of the vessels is produced by only using information from certain segmented layers. Finally, a supervised, pixel classification based vessel segmentation approach is applied to the projection image. We compared the influence of two methods for the projection on the performance of the vessel segmentation on 10 optic nerve head centered 3D OCT scans. The method was trained on 5 independent scans. Using ROC analysis, our proposed vessel segmentation system obtains an area under the curve of 0.970 when compared with the segmentation of a human observer.

  12. 3-D reconstruction of neurons from multichannel confocal laser scanning image series.

    PubMed

    Wouterlood, Floris G

    2014-04-10

    A confocal laser scanning microscope (CLSM) collects information from a thin, focal plane and ignores out-of-focus information. Scanning of a specimen, with stepwise axial (Z-) movement of the stage in between each scan, produces Z-series of confocal images of a tissue volume, which then can be used to 3-D reconstruct structures of interest. The operator first configures separate channels (e.g., laser, filters, and detector settings) for each applied fluorochrome and then acquires Z-series of confocal images: one series per channel. Channel signal separation is extremely important. Measures to avoid bleaching are vital. Post-acquisition deconvolution of the image series is often performed to increase resolution before 3-D reconstruction takes place. In the 3-D reconstruction programs described in this unit, reconstructions can be inspected in real time from any viewing angle. By altering viewing angles and by switching channels off and on, the spatial relationships of 3-D-reconstructed structures with respect to structures visualized in other channels can be studied. Since each brand of CLSM, computer program, and 3-D reconstruction package has its own proprietary set of procedures, a general approach is provided in this protocol wherever possible.

  13. Reconstruction of 3-D cloud geometry using a scanning cloud radar

    NASA Astrophysics Data System (ADS)

    Ewald, F.; Winkler, C.; Zinner, T.

    2014-11-01

    Clouds are one of the main reasons of uncertainties in the forecasts of weather and climate. In part, this is due to limitations of remote sensing of cloud microphysics. Present approaches often use passive spectral measurements for the remote sensing of cloud microphysical parameters. Large uncertainties are introduced by three dimensional (3-D) radiative transfer effects and cloud inhomogeneities. Such effects are largely caused by unknown orientation of cloud sides or by shadowed areas on the cloud. Passive ground based remote sensing of cloud properties at high spatial resolution could be improved crucially with this kind of additional knowledge of cloud geometry. To this end, a method for the accurate reconstruction of 3-D cloud geometry from cloud radar measurements is developed in this work. Using a radar simulator and simulated passive measurements of static LES model clouds, the effects of different radar scan resolutions and varying interpolation methods are evaluated. In reality a trade-off between scan resolution and scan duration has to be found as clouds are changing quickly. A reasonable choice is a scan resolution of 1 to 2°. The most suitable interpolation procedure identified is the barycentric interpolation method. The 3-D reconstruction method is demonstrated using radar scans of convective cloud cases with the Munich miraMACS, a 35 GHz scanning cloud radar. As a successful proof of concept, camera imagery collected at the radar location is reproduced for the observed cloud cases via 3-D volume reconstruction and 3-D radiative transfer simulation. Data sets provided by the presented reconstruction method will aid passive spectral ground-based measurements of cloud sides to retrieve microphysical parameters.

  14. 3-D reconstruction of neurons from multichannel confocal laser scanning image series.

    PubMed

    Wouterlood, Floris G

    2005-08-01

    A confocal laser scanning microscope (CLSM) collects information from a thin, focal plane and ignores out-of-focus information. The operator configures separate channels (laser, filters, detector settings) for each fluorochrome used in a particular experiment. Then, 3-D reconstructions are made from Z-series of confocal images: one series per channel. Channel signal separation is extremely important and measures to avoid bleaching are vital. Post-acquisition deconvolution of the image series is then performed to increase resolution. In the 3-D reconstruction program described in this unit, reconstructions can be inspected in real time from any viewing angle. By altering viewing angles and by switching channels off and on, the spatial relationship of 3-D-reconstructed structures with respect to structures seen in other channels can be studied. Since each brand of CLSM, computer program, and 3-D reconstruction package has its own proprietary set of procedures, a general approach is provided wherever possible.

  15. The role of terrestrial 3D LiDAR scan in bridge health monitoring

    NASA Astrophysics Data System (ADS)

    Liu, Wanqiu; Chen, Shen-En; Sajedi, Allen; Hauser, Edd

    2010-04-01

    This paper addresses the potential applications of terrestrial 3D LiDAR scanning technologies for bridge monitoring. High resolution ground-based optical-photonic images from LiDAR scans can provide detailed geometric information about a bridge. Applications of simple algorithms can retrieve damage information from the geometric point cloud data, which can be correlated to possible damage quantification including concrete mass loss due to vehicle collisions, large permanent steel deformations, and surface erosions. However, any proposed damage detection technologies should provide information that is relevant and useful to bridge managers for their decision making process. This paper summaries bridge issues that can be detected from the 3D LiDAR technologies, establishes the general approach in using 3D point clouds for damage evaluation and suggests possible bridge state ratings that can be used as supplements to existing bridge management systems (BMS).

  16. A Laser Line Auto-Scanning System for Underwater 3D Reconstruction.

    PubMed

    Chi, Shukai; Xie, Zexiao; Chen, Wenzhu

    2016-09-20

    In this study, a laser line auto-scanning system was designed to perform underwater close-range 3D reconstructions with high accuracy and resolution. The system changes the laser plane direction with a galvanometer to perform automatic scanning and obtain continuous laser strips for underwater 3D reconstruction. The system parameters were calibrated with the homography constraints between the target plane and image plane. A cost function was defined to optimize the galvanometer's rotating axis equation. Compensation was carried out for the refraction of the incident and emitted light at the interface. The accuracy and the spatial measurement capability of the system were tested and analyzed with standard balls under laboratory underwater conditions, and the 3D surface reconstruction for a sealing cover of an underwater instrument was proved to be satisfactory.

  17. A Laser Line Auto-Scanning System for Underwater 3D Reconstruction

    PubMed Central

    Chi, Shukai; Xie, Zexiao; Chen, Wenzhu

    2016-01-01

    In this study, a laser line auto-scanning system was designed to perform underwater close-range 3D reconstructions with high accuracy and resolution. The system changes the laser plane direction with a galvanometer to perform automatic scanning and obtain continuous laser strips for underwater 3D reconstruction. The system parameters were calibrated with the homography constraints between the target plane and image plane. A cost function was defined to optimize the galvanometer’s rotating axis equation. Compensation was carried out for the refraction of the incident and emitted light at the interface. The accuracy and the spatial measurement capability of the system were tested and analyzed with standard balls under laboratory underwater conditions, and the 3D surface reconstruction for a sealing cover of an underwater instrument was proved to be satisfactory. PMID:27657074

  18. Hybrid wide-field and scanning microscopy for high-speed 3D imaging.

    PubMed

    Duan, Yubo; Chen, Nanguang

    2015-11-15

    Wide-field optical microscopy is efficient and robust in biological imaging, but it lacks depth sectioning. In contrast, scanning microscopic techniques, such as confocal microscopy and multiphoton microscopy, have been successfully used for three-dimensional (3D) imaging with optical sectioning capability. However, these microscopic techniques are not very suitable for dynamic real-time imaging because they usually take a long time for temporal and spatial scanning. Here, a hybrid imaging technique combining wide-field microscopy and scanning microscopy is proposed to accelerate the image acquisition process while maintaining the 3D optical sectioning capability. The performance was demonstrated by proof-of-concept imaging experiments with fluorescent beads and zebrafish liver.

  19. Mapping gray-scale image to 3D surface scanning data by ray tracing

    NASA Astrophysics Data System (ADS)

    Li, Peng; Jones, Peter R. M.

    1997-03-01

    The extraction and location of feature points from range imaging is an important but difficult task in machine vision based measurement systems. There exist some feature points which are not able to be detected from pure geometric characteristics, particularly in those measurement tasks related to the human body. The Loughborough Anthropometric Shadow Scanner (LASS) is a whole body surface scanner based on structured light technique. Certain applications of LASS require accurate location of anthropometric landmarks from the scanned data. This is sometimes impossible from existing raw data because some landmarks do not appear in the scanned data. Identification of these landmarks has to resort to surface texture of the scanned object. Modifications to LASS were made to allow gray-scale images to be captured before or after the object was scanned. Two-dimensional gray-scale image must be mapped to the scanned data to acquire the 3D coordinates of a landmark. The method to map 2D images to the scanned data is based on the colinearity conditions and ray-tracing method. If the camera center and image coordinates are known, the corresponding object point must lie on a ray starting from the camera center and connecting to the image coordinate. By intersecting the ray with the scanned surface of the object, the 3D coordinates of a point can be solved. Experimentation has demonstrated the feasibility of the method.

  20. Bore-Sight Calibration of Multiple Laser Range Finders for Kinematic 3D Laser Scanning Systems.

    PubMed

    Jung, Jaehoon; Kim, Jeonghyun; Yoon, Sanghyun; Kim, Sangmin; Cho, Hyoungsig; Kim, Changjae; Heo, Joon

    2015-05-04

    The Simultaneous Localization and Mapping (SLAM) technique has been used for autonomous navigation of mobile systems; now, its applications have been extended to 3D data acquisition of indoor environments. In order to reconstruct 3D scenes of indoor space, the kinematic 3D laser scanning system, developed herein, carries three laser range finders (LRFs): one is mounted horizontally for system-position correction and the other two are mounted vertically to collect 3D point-cloud data of the surrounding environment along the system's trajectory. However, the kinematic laser scanning results can be impaired by errors resulting from sensor misalignment. In the present study, the bore-sight calibration of multiple LRF sensors was performed using a specially designed double-deck calibration facility, which is composed of two half-circle-shaped aluminum frames. Moreover, in order to automatically achieve point-to-point correspondences between a scan point and the target center, a V-shaped target was designed as well. The bore-sight calibration parameters were estimated by a constrained least squares method, which iteratively minimizes the weighted sum of squares of residuals while constraining some highly-correlated parameters. The calibration performance was analyzed by means of a correlation matrix. After calibration, the visual inspection of mapped data and residual calculation confirmed the effectiveness of the proposed calibration approach.

  1. Bore-Sight Calibration of Multiple Laser Range Finders for Kinematic 3D Laser Scanning Systems

    PubMed Central

    Jung, Jaehoon; Kim, Jeonghyun; Yoon, Sanghyun; Kim, Sangmin; Cho, Hyoungsig; Kim, Changjae; Heo, Joon

    2015-01-01

    The Simultaneous Localization and Mapping (SLAM) technique has been used for autonomous navigation of mobile systems; now, its applications have been extended to 3D data acquisition of indoor environments. In order to reconstruct 3D scenes of indoor space, the kinematic 3D laser scanning system, developed herein, carries three laser range finders (LRFs): one is mounted horizontally for system-position correction and the other two are mounted vertically to collect 3D point-cloud data of the surrounding environment along the system’s trajectory. However, the kinematic laser scanning results can be impaired by errors resulting from sensor misalignment. In the present study, the bore-sight calibration of multiple LRF sensors was performed using a specially designed double-deck calibration facility, which is composed of two half-circle-shaped aluminum frames. Moreover, in order to automatically achieve point-to-point correspondences between a scan point and the target center, a V-shaped target was designed as well. The bore-sight calibration parameters were estimated by a constrained least squares method, which iteratively minimizes the weighted sum of squares of residuals while constraining some highly-correlated parameters. The calibration performance was analyzed by means of a correlation matrix. After calibration, the visual inspection of mapped data and residual calculation confirmed the effectiveness of the proposed calibration approach. PMID:25946627

  2. A Survey Study of the Blast Furnace at Kuangshan Village Using 3D Laser Scanning

    NASA Astrophysics Data System (ADS)

    Wang, Jin; Huang, Xing; Qian, Wei

    2017-01-01

    The blast furnace from the Northern Song Dynasty at Kuangshan Village is the tallest blast furnace that remains from ancient China. Previous studies have assumed that the furnace had a closed mouth. In this paper, a three-dimensional (3D) model of the blast furnace is constructed using 3D laser scanning technology, and accurate profile data are obtained using software. It is shown that the furnace throat is smaller than had been previously thought and that the furnace mouth is of the open type. This new furnace profile constitutes a discovery in the history of iron-smelting technology.

  3. Ship Maintenance Processes with Collaborative Product Lifecycle Management and 3D Terrestrial Laser Scanning Tools: Reducing Costs and Increasing Productivity

    DTIC Science & Technology

    2012-04-30

    approach that incorporates the 3D terrestrial laser scanning (3D TLS) and collaborative product lifecycle management (collab- PLM ) tool suite. Results...incorporated into final implementation of the 3D TLS and collab- PLM tools. 15. SUBJECT TERMS 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF...terrestrial laser scanning (3D TLS) and collaborative product lifecycle management (collab- PLM ) tool suite. Results suggest that when the SHIPMAIN process

  4. Scanning Cloud Radar Observations at Azores: Preliminary 3D Cloud Products

    SciTech Connect

    Kollias, P.; Johnson, K.; Jo, I.; Tatarevic, A.; Giangrande, S.; Widener, K.; Bharadwaj, N.; Mead, J.

    2010-03-15

    The deployment of the Scanning W-Band ARM Cloud Radar (SWACR) during the AMF campaign at Azores signals the first deployment of an ARM Facility-owned scanning cloud radar and offers a prelude for the type of 3D cloud observations that ARM will have the capability to provide at all the ARM Climate Research Facility sites by the end of 2010. The primary objective of the deployment of Scanning ARM Cloud Radars (SACRs) at the ARM Facility sites is to map continuously (operationally) the 3D structure of clouds and shallow precipitation and to provide 3D microphysical and dynamical retrievals for cloud life cycle and cloud-scale process studies. This is a challenging task, never attempted before, and requires significant research and development efforts in order to understand the radar's capabilities and limitations. At the same time, we need to look beyond the radar meteorology aspects of the challenge and ensure that the hardware and software capabilities of the new systems are utilized for the development of 3D data products that address the scientific needs of the new Atmospheric System Research (ASR) program. The SWACR observations at Azores provide a first look at such observations and the challenges associated with their analysis and interpretation. The set of scan strategies applied during the SWACR deployment and their merit is discussed. The scan strategies were adjusted for the detection of marine stratocumulus and shallow cumulus that were frequently observed at the Azores deployment. Quality control procedures for the radar reflectivity and Doppler products are presented. Finally, preliminary 3D-Active Remote Sensing of Cloud Locations (3D-ARSCL) products on a regular grid will be presented, and the challenges associated with their development discussed. In addition to data from the Azores deployment, limited data from the follow-up deployment of the SWACR at the ARM SGP site will be presented. This effort provides a blueprint for the effort required for the

  5. 3D laser scanning and modelling of the Dhow heritage for the Qatar National Museum

    NASA Astrophysics Data System (ADS)

    Wetherelt, A.; Cooper, J. P.; Zazzaro, C.

    2014-08-01

    Curating boats can be difficult. They are complex structures, often demanding to conserve whether in or out of the water; they are usually large, difficult to move on land, and demanding of gallery space. Communicating life on board to a visiting public in the terra firma context of a museum can be difficult. Boats in their native environment are inherently dynamic artifacts. In a museum they can be static and divorced from the maritime context that might inspire engagement. New technologies offer new approaches to these problems. 3D laser scanning and digital modeling offers museums a multifaceted means of recording, monitoring, studying and communicating watercraft in their care. In this paper we describe the application of 3D laser scanning and subsequent digital modeling. Laser scans were further developed using computer-generated imagery (CGI) modeling techniques to produce photorealistic 3D digital models for development into interactive, media-based museum displays. The scans were also used to generate 2D naval lines and orthographic drawings as a lasting curatorial record of the dhows held by the National Museum of Qatar.

  6. Autonomous Real-Time Interventional Scan Plane Control With a 3-D Shape-Sensing Needle

    PubMed Central

    Plata, Juan Camilo; Holbrook, Andrew B.; Park, Yong-Lae; Pauly, Kim Butts; Daniel, Bruce L.; Cutkosky, Mark R.

    2016-01-01

    This study demonstrates real-time scan plane control dependent on three-dimensional needle bending, as measured from magnetic resonance imaging (MRI)-compatible optical strain sensors. A biopsy needle with embedded fiber Bragg grating (FBG) sensors to measure surface strains is used to estimate its full 3-D shape and control the imaging plane of an MR scanner in real-time, based on the needle’s estimated profile. The needle and scanner coordinate frames are registered to each other via miniature radio-frequency (RF) tracking coils, and the scan planes autonomously track the needle as it is deflected, keeping its tip in view. A 3-D needle annotation is superimposed over MR-images presented in a 3-D environment with the scanner’s frame of reference. Scan planes calculated based on the FBG sensors successfully follow the tip of the needle. Experiments using the FBG sensors and RF coils to track the needle shape and location in real-time had an average root mean square error of 4.2 mm when comparing the estimated shape to the needle profile as seen in high resolution MR images. This positional variance is less than the image artifact caused by the needle in high resolution SPGR (spoiled gradient recalled) images. Optical fiber strain sensors can estimate a needle’s profile in real-time and be used for MRI scan plane control to potentially enable faster and more accurate physician response. PMID:24968093

  7. Autonomous real-time interventional scan plane control with a 3-D shape-sensing needle.

    PubMed

    Elayaperumal, Santhi; Plata, Juan Camilo; Holbrook, Andrew B; Park, Yong-Lae; Pauly, Kim Butts; Daniel, Bruce L; Cutkosky, Mark R

    2014-11-01

    This study demonstrates real-time scan plane control dependent on three-dimensional needle bending, as measured from magnetic resonance imaging (MRI)-compatible optical strain sensors. A biopsy needle with embedded fiber Bragg grating (FBG) sensors to measure surface strains is used to estimate its full 3-D shape and control the imaging plane of an MR scanner in real-time, based on the needle's estimated profile. The needle and scanner coordinate frames are registered to each other via miniature radio-frequency (RF) tracking coils, and the scan planes autonomously track the needle as it is deflected, keeping its tip in view. A 3-D needle annotation is superimposed over MR-images presented in a 3-D environment with the scanner's frame of reference. Scan planes calculated based on the FBG sensors successfully follow the tip of the needle. Experiments using the FBG sensors and RF coils to track the needle shape and location in real-time had an average root mean square error of 4.2 mm when comparing the estimated shape to the needle profile as seen in high resolution MR images. This positional variance is less than the image artifact caused by the needle in high resolution SPGR (spoiled gradient recalled) images. Optical fiber strain sensors can estimate a needle's profile in real-time and be used for MRI scan plane control to potentially enable faster and more accurate physician response.

  8. Design of 3D isotropic metamaterial device using smart transformation optics.

    PubMed

    Shin, Dongheok; Kim, Junhyun; Yoo, Do-Sik; Kim, Kyoungsik

    2015-08-24

    We report here a design method for a 3 dimensional (3D) isotropic transformation optical device using smart transformation optics. Inspired by solid mechanics, smart transformation optics regards a transformation optical medium as an elastic solid and deformations as coordinate transformations. Further developing from our previous work on 2D smart transformation optics, we introduce a method of 3D smart transformation optics to design 3D transformation optical devices by maintaining isotropic materials properties for all types of polarizations imposing free or nearly free boundary conditions. Due to the material isotropy, it is possible to fabricate such devices with structural metamaterials made purely of common dielectric materials. In conclusion, the practical importance of the method reported here lies in the fact that it enables us to fabricate, without difficulty, arbitrarily shaped 3D devices with existing 3D printing technology.

  9. Methodology of the determination of the uncertainties by using the biometric device the broadway 3D

    NASA Astrophysics Data System (ADS)

    Jasek, Roman; Talandova, Hana; Adamek, Milan

    2016-06-01

    The biometric identification by face is among one of the most widely used methods of biometric identification. Due to it provides a faster and more accurate identification; it was implemented into area of security 3D face reader by Broadway manufacturer was used to measure. It is equipped with the 3D camera system, which uses the method of structured light scanning and saves the template into the 3D model of face. The obtained data were evaluated by software Turnstile Enrolment Application (TEA). The measurements were used 3D face reader the Broadway 3D. First, the person was scanned and stored in the database. Thereafter person has already been compared with the stored template in the database for each method. Finally, a measure of reliability was evaluated for the Broadway 3D face reader.

  10. Variation in the measurement of cranial volume and surface area using 3D laser scanning technology.

    PubMed

    Sholts, Sabrina B; Wärmländer, Sebastian K T S; Flores, Louise M; Miller, Kevin W P; Walker, Phillip L

    2010-07-01

    Three-dimensional (3D) laser scanner models of human crania can be used for forensic facial reconstruction, and for obtaining craniometric data useful for estimating age, sex, and population affinity of unidentified human remains. However, the use of computer-generated measurements in a casework setting requires the measurement precision to be known. Here, we assess the repeatability and precision of cranial volume and surface area measurements using 3D laser scanner models created by different operators using different protocols for collecting and processing data. We report intraobserver measurement errors of 0.2% and interobserver errors of 2% of the total area and volume values, suggesting that observer-related errors do not pose major obstacles for sharing, combining, or comparing such measurements. Nevertheless, as no standardized procedure exists for area or volume measurements from 3D models, it is imperative to report the scanning and postscanning protocols employed when such measurements are conducted in a forensic setting.

  11. Documentation and Instructions for Running Two Python Scripts that Aid in Setting up 3D Measurements using the Polytec 3D Scanning Laser Doppler Vibrometer.

    SciTech Connect

    Rohe, Daniel Peter

    2015-08-24

    Sandia National Laboratories has recently purchased a Polytec 3D Scanning Laser Doppler Vibrometer for vibration measurement. This device has proven to be a very nice tool for making vibration measurements, and has a number of advantages over traditional sensors such as accelerometers. The non-contact nature of the laser vibrometer means there is no mass loading due to measuring the response. Additionally, the laser scanning heads can position the laser spot much more quickly and accurately than placing an accelerometer or performing a roving hammer impact. The disadvantage of the system is that a significant amount of time must be invested to align the lasers with each other and the part so that the laser spots can be accurately positioned. The Polytec software includes a number of nice tools to aid in this procedure; however, certain portions are still tedious. Luckily, the Polytec software is readily extensible by programming macros for the system, so tedious portions of the procedure can be made easier by automating the process. The Polytec Software includes a WinWrap (similar to Visual Basic) editor and interface to run macros written in that programming language. The author, however, is much more proficient in Python, and the latter also has a much larger set of libraries that can be used to create very complex macros, while taking advantage of Python’s inherent readability and maintainability.

  12. Triangular mesh establishment of 3D laser scanning data based on ellipsoidal projection

    NASA Astrophysics Data System (ADS)

    Zheng, De-hua; Xu, Jia; Li, Jia; Wang, Xin-sen

    2011-10-01

    The establishment of high quality triangular mesh is one of the key steps in 3D laser scanning data processing. Traditional triangulation algorithms have been proposed directly on the basis of adjacency relation between points in 3D space. However, when the point density is non-uniform or the noise exists, the problems such as surface hole, dough sheet overlapping and inconsistent normal appear easily. In this paper, a triangular mesh establishing algorithm based on ellipsoidal projection is proposed. After comparing the theory of ellipsoidal projection and cylindrical projection, the proposed triangular mesh establishing algorithm is analyzed in detail including basic idea and implementation method. To evaluate the performance and efficiency of the proposed algorithm, two experiments are then carried out on the 3D point cloud data of a foundation pit. The results indicate that though the computational efficiency of proposed algorithm is a little inferior to the algorithm based on cylindrical projection, the proposed algorithm is more effective for establishing point cloud of both top and bottom of the object and the original topological relation of 3D scanning points can be maintained better.

  13. Novel scanning electron microscopy methods for analyzing the 3D structure of the Golgi apparatus.

    PubMed

    Koga, Daisuke; Ushiki, Tatsuo; Watanabe, Tsuyoshi

    2017-01-01

    The structure of the Golgi apparatus has been extensively examined by light and electron microscopy, but details of its three-dimensional (3D) structure have remained unclear because of the technical limitations of conventional microscopy techniques. To overcome this problem, we have developed several novel scanning electron microscopy (SEM) methods for observing the 3D structure of subcellular organelles including the Golgi apparatus: (1) an osmium maceration method that facilitates SEM observation of membranous organelles, including the Golgi apparatus, by selectively removing soluble cytoplasmic proteins, (2) an osmium impregnation/maceration method that combines an osmium impregnation method with the osmium maceration method to determine the polarity of the Golgi apparatus by SEM, (3) a correlative light and SEM method that combines a cryosectioning technique with the osmium maceration method to enable correlation of the immunocytochemical distribution of molecules with the 3D ultrastructure of the Golgi apparatus, and (4) array tomography based on the systematic collection and integration of SEM images of serial ultrathin sections on glass slides for revealing the 3D ultrastructure of the entire Golgi apparatus. Together, the novel SEM techniques listed above can reveal the complete 3D structure of the Golgi apparatus in different cell types.

  14. Audiovisual biofeedback improves image quality and reduces scan time for respiratory-gated 3D MRI

    NASA Astrophysics Data System (ADS)

    Lee, D.; Greer, P. B.; Arm, J.; Keall, P.; Kim, T.

    2014-03-01

    The purpose of this study was to test the hypothesis that audiovisual (AV) biofeedback can improve image quality and reduce scan time for respiratory-gated 3D thoracic MRI. For five healthy human subjects respiratory motion guidance in MR scans was provided using an AV biofeedback system, utilizing real-time respiratory motion signals. To investigate the improvement of respiratory-gated 3D MR images between free breathing (FB) and AV biofeedback (AV), each subject underwent two imaging sessions. Respiratory-related motion artifacts and imaging time were qualitatively evaluated in addition to the reproducibility of external (abdominal) motion. In the results, 3D MR images in AV biofeedback showed more anatomic information such as a clear distinction of diaphragm, lung lobes and sharper organ boundaries. The scan time was reduced from 401±215 s in FB to 334±94 s in AV (p-value 0.36). The root mean square variation of the displacement and period of the abdominal motion was reduced from 0.4±0.22 cm and 2.8±2.5 s in FB to 0.1±0.15 cm and 0.9±1.3 s in AV (p-value of displacement <0.01 and p-value of period 0.12). This study demonstrated that audiovisual biofeedback improves image quality and reduces scan time for respiratory-gated 3D MRI. These results suggest that AV biofeedback has the potential to be a useful motion management tool in medical imaging and radiation therapy procedures.

  15. 3D scanning electron microscopy applied to surface characterization of fluorosed dental enamel.

    PubMed

    Limandri, Silvina; Galván Josa, Víctor; Valentinuzzi, María Cecilia; Chena, María Emilia; Castellano, Gustavo

    2016-05-01

    The enamel surfaces of fluorotic teeth were studied by scanning electron stereomicroscopy. Different whitening treatments were applied to 25 pieces to remove stains caused by fluorosis and their surfaces were characterized by stereomicroscopy in order to obtain functional and amplitude parameters. The topographic features resulting for each treatment were determined through these parameters. The results obtained show that the 3D reconstruction achieved from the SEM stereo pairs is a valuable potential alternative for the surface characterization of this kind of samples.

  16. Analysis of thin baked-on silicone layers by FTIR and 3D-Laser Scanning Microscopy.

    PubMed

    Funke, Stefanie; Matilainen, Julia; Nalenz, Heiko; Bechtold-Peters, Karoline; Mahler, Hanns-Christian; Friess, Wolfgang

    2015-10-01

    Pre-filled syringes (PFS) and auto-injection devices with cartridges are increasingly used for parenteral administration. To assure functionality, silicone oil is applied to the inner surface of the glass barrel. Silicone oil migration into the product can be minimized by applying a thin but sufficient layer of silicone oil emulsion followed by thermal bake-on versus spraying-on silicone oil. Silicone layers thicker than 100nm resulting from regular spray-on siliconization can be characterized using interferometric profilometers. However, the analysis of thin silicone layers generated by bake-on siliconization is more challenging. In this paper, we have evaluated Fourier transform infrared (FTIR) spectroscopy after solvent extraction and a new 3D-Laser Scanning Microscopy (3D-LSM) to overcome this challenge. A multi-step solvent extraction and subsequent FTIR spectroscopy enabled to quantify baked-on silicone levels as low as 21-325μg per 5mL cartridge. 3D-LSM was successfully established to visualize and measure baked-on silicone layers as thin as 10nm. 3D-LSM was additionally used to analyze the silicone oil distribution within cartridges at such low levels. Both methods provided new, highly valuable insights to characterize the siliconization after processing, in order to achieve functionality.

  17. Application of 3D scanned imaging methodology for volume, surface area, and envelope density evaluation of densified biomass.

    PubMed

    Igathinathane, C; Davis, J D; Purswell, J L; Columbus, E P

    2010-06-01

    Measurement of volume, surface area, and density is an essential for quantifying, evaluating, and designing the biomass densification, storage, and transport operations. Acquiring accurate and repeated measurements of these parameters for hygroscopic densified biomass are not straightforward and only a few methods are available. A 3D laser scanner was used as a measurement device and the 3D images were analyzed using image processing software. The validity of the method was verified using reference objects of known geometry and the accuracy obtained was in excess of 98%. Cotton gin trash briquettes, switchgrass pellets, switchgrass cubes, hardwood pellets, and softwood chips were tested. Most accurate results of the volume and surface area required the highest possible resolution of the scanner, which increased the total scan-process times, and image file size. Physical property determination using the 3D scanning and image analysis is highly repeatable (coefficient of variation <0.3%), non-invasive, accurate, and alternative methodology. The various limitations and merits of the developed method were also enumerated.

  18. Analysis of the Possibilities of Using Low-Cost Scanning System in 3d Modeling

    NASA Astrophysics Data System (ADS)

    Kedzierski, M.; Wierzbickia, D.; Fryskowska, A.; Chlebowska, B.

    2016-06-01

    The laser scanning technique is still a very popular and fast growing method of obtaining information on modeling 3D objects. The use of low-cost miniature scanners creates new opportunities for small objects of 3D modeling based on point clouds acquired from the scan. The same, the development of accuracy and methods of automatic processing of this data type is noticeable. The article presents methods of collecting raw datasets in the form of a point-cloud using a low-cost ground-based laser scanner FabScan. As part of the research work 3D scanner from an open source FabLab project was constructed. In addition, the results for the analysis of the geometry of the point clouds obtained by using a low-cost laser scanner were presented. Also, some analysis of collecting data of different structures (made of various materials such as: glass, wood, paper, gum, plastic, plaster, ceramics, stoneware clay etc. and of different shapes: oval and similar to oval and prism shaped) have been done. The article presents two methods used for analysis: the first one - visual (general comparison between the 3D model and the real object) and the second one - comparative method (comparison between measurements on models and scanned objects using the mean error of a single sample of observations). The analysis showed, that the low-budget ground-based laser scanner FabScan has difficulties with collecting data of non-oval objects. Items built of glass painted black also caused problems for the scanner. In addition, the more details scanned object contains, the lower the accuracy of the collected point-cloud is. Nevertheless, the accuracy of collected data (using oval-straight shaped objects) is satisfactory. The accuracy, in this case, fluctuates between ± 0,4 mm and ± 1,0 mm whereas when using more detailed objects or a rectangular shaped prism the accuracy is much more lower, between 2,9 mm and ± 9,0 mm. Finally, the publication presents the possibility (for the future expansion of

  19. Combined scanning probe nanotomography and optical microspectroscopy: a correlative technique for 3D characterization of nanomaterials.

    PubMed

    Mochalov, Konstantin E; Efimov, Anton E; Bobrovsky, Alexey; Agapov, Igor I; Chistyakov, Anton A; Oleinikov, Vladimir; Sukhanova, Alyona; Nabiev, Igor

    2013-10-22

    Combination of 3D structural analysis with optical characterization of the same sample area on the nanoscale is a highly demanded approach in nanophotonics, materials science, and quality control of nanomaterial. We have developed a correlative microscopy technique where the 3D structure of the sample is reconstructed on the nanoscale by means of a "slice-and-view" combination of ultramicrotomy and scanning probe microscopy (scanning probe nanotomography, SPNT), and its optical characteristics are analyzed using microspectroscopy. This approach has been used to determine the direct quantitative relationship of the 3D structural characteristics of nanovolumes of materials with their microscopic optical properties. This technique has been applied to 3D structural and optical characterization of a hybrid material consisting of cholesteric liquid crystals doped with fluorescent quantum dots (QDs) that can be used for photochemical patterning and image recording through the changes in the dissymmetry factor of the circular polarization of QD emission. The differences in the polarization images and fluorescent spectra of this hybrid material have proved to be correlated with the arrangement of the areas of homogeneous distribution and heterogeneous clustering of QDs. The reconstruction of the 3D nanostructure of the liquid crystal matrix in the areas of homogeneous QDs distribution has shown that QDs do not perturb the periodic planar texture of the cholesteric liquid crystal matrix, whereas QD clusters do perturb it. The combined microspectroscopy-nanotomography technique will be important for evaluating the effects of nanoparticles on the structural organization of organic and liquid crystal matrices and biomedical materials, as well as quality control of nanotechnology fabrication processes and products.

  20. 3D quantitative imaging of the microvasculature with the Texas Instruments Digital Micromirror Device

    NASA Astrophysics Data System (ADS)

    Fainman, Yeshaiahu; Botvinick, Elliott L.; Price, Jeffrey H.; Gough, David A.

    2001-11-01

    There is a growing need for developing 3D quantitative imaging tools that can operate at high speed enabling real-time visualization for the field of biology, material science, and the semiconductor industry. We will present our 3D quantitative imaging system based on a confocal microscope built with a Texas Instruments Digital Micromirror Device (DMD). By using the DMD as a spatial light modulator, confocal transverse surface (x, y) scanning can be performed in parallel at speeds faster than video rate without physical movement of the sample. The DMD allows us to programmably configure the source and the detection pinhole array in the lateral direction to achieve the best signal and to reduce the crosstalk noise. Investigations of the microcirculation were performed on 40 g to 45 g golden Syrian hamsters fit with dorsal skin fold window chambers. FITC-Dextran or Red blood cells from donor hamsters, stained with Celltracker CM-DiI, were injected into the circulation and imaged with the confocal microscope. We will present the measured results for the axial resolution, in vivo, as well as experimental results from imaging the window chamber.

  1. Towards fabrication of 3D printed medical devices to prevent biofilm formation.

    PubMed

    Sandler, Niklas; Salmela, Ida; Fallarero, Adyary; Rosling, Ari; Khajeheian, Mohammad; Kolakovic, Ruzica; Genina, Natalja; Nyman, Johan; Vuorela, Pia

    2014-01-01

    The use of three-dimensional (3D) printing technologies is transforming the way that materials are turned into functional devices. We demonstrate in the current study the incorporation of anti-microbial nitrofurantoin in a polymer carrier material and subsequent 3D printing of a model structure, which resulted in an inhibition of biofilm colonization. The approach taken is very promising and can open up new avenues to manufacture functional medical devices in the future.

  2. Long-range laser scanning and 3D imaging for the Gneiss quarries survey

    NASA Astrophysics Data System (ADS)

    Schenker, Filippo Luca; Spataro, Alessio; Pozzoni, Maurizio; Ambrosi, Christian; Cannata, Massimiliano; Günther, Felix; Corboud, Federico

    2016-04-01

    In Canton Ticino (Southern Switzerland), the exploitation of natural stone, mostly gneisses, is an important activity of valley's economies. Nowadays, these economic activities are menaced by (i) the exploitation costs related to geological phenomena such as fractures, faults and heterogeneous rocks that hinder the processing of the stone product, (ii) continuously changing demand because of the evolving natural stone fashion and (iii) increasing administrative limits and rules acting to protect the environment. Therefore, the sustainable development of the sector for the next decades needs new and effective strategies to regulate and plan the quarries. A fundamental step in this process is the building of a 3D geological model of the quarries to constrain the volume of commercial natural stone and the volume of waste. In this context, we conducted Terrestrial Laser Scanning surveys of the quarries in the Maggia Valley to obtain a detailed 3D topography onto which the geological units were mapped. The topographic 3D model was obtained with a long-range laser scanning Riegl VZ4000 that can measure from up to 4 km of distance with a speed of 147,000 points per second. It operates with the new V-line technology, which defines the surface relief by sensing differentiated signals (echoes), even in the presence of obstacles such as vegetation. Depending on the esthetics of the gneisses, we defined seven types of natural stones that, together with faults and joints, were mapped onto the 3D models of the exploitation sites. According to the orientation of the geological limits and structures, we projected the different rock units and fractures into the excavation front. This way, we obtained a 3D geological model from which we can quantitatively estimate the volume of the seven different natural stones (with different commercial value) and waste (with low commercial value). To verify the 3D geological models and to quantify exploited rock and waste volumes the same

  3. Robust near-infrared structured light scanning for 3D human model reconstruction

    NASA Astrophysics Data System (ADS)

    Fu, Bo; Yang, Ruigang

    2014-03-01

    In this paper we present a novel sensing system, robust Near-infrared Structured Light Scanning (NIRSL) for three-dimensional human model scanning application. Human model scanning due to its nature of various hair and dress appearance and body motion has long been a challenging task. Previous structured light scanning methods typically emitted visible coded light patterns onto static and opaque objects to establish correspondence between a projector and a camera for triangulation. In the success of these methods rely on scanning objects with proper reflective surface for visible light, such as plaster, light colored cloth. Whereas for human model scanning application, conventional methods suffer from low signal to noise ratio caused by low contrast of visible light over the human body. The proposed robust NIRSL, as implemented with the near infrared light, is capable of recovering those dark surfaces, such as hair, dark jeans and black shoes under visible illumination. Moreover, successful structured light scan relies on the assumption that the subject is static during scanning. Due to the nature of body motion, it is very time sensitive to keep this assumption in the case of human model scan. The proposed sensing system, by utilizing the new near-infrared capable high speed LightCrafter DLP projector, is robust to motion, provides accurate and high resolution three-dimensional point cloud, making our system more efficient and robust for human model reconstruction. Experimental results demonstrate that our system is effective and efficient to scan real human models with various dark hair, jeans and shoes, robust to human body motion and produces accurate and high resolution 3D point cloud.

  4. Implementation of 3D prostrate ring-scanning mechanism for NIR diffuse optical imaging phantom validation

    NASA Astrophysics Data System (ADS)

    Yu, Jhao-Ming; Chen, Liang-Yu; Pan, Min-Cheng; Hsu, Ya-Fen; Pan, Min-Chun

    2015-03-01

    Diffuse optical imaging (DOI) providing functional information of tissues has drawn great attention for the last two decades. Near infrared (NIR) DOI systems composed of scanning bench, opt-electrical measurement module, system control, and data processing and image reconstruction schemes are developed for the screening and diagnosis of breast tumors. Mostly, the scanning bench belonging to fixed source-and-detector configuration limits computed image resolution to an extent. To cope with the issue, we propose, design and implement a 3D prostrate ring-scanning equipment for NIR DOI with flexible combinations of illumination and detection, and with the function of radial, circular and vertical movement without hard compression of breast tissue like the imaging system using or incorporating with X-ray mammographic bench. Especially, a rotation-sliding-and-moving mechanism was designed for the guidance of source- and detection-channel movement. Following the previous justification for synthesized image reconstruction, in the paper the validation using varied phantoms is further conducted and 3D image reconstruction for their absorption and scattering coefficients is illustrated through the computation of our in-house coded schemes. The source and detection NIR data are acquired to reconstruct the 3D images through the operation of scanning bench in the movement of vertical, radial and circular directions. Rather than the fixed configuration, the addressed screening/diagnosing equipment has the flexibility for optical-channel expansion with a compromise among construction cost, operation time, and spatial resolution of reconstructed μa and μs' images.

  5. Regulatory Considerations in the Design and Manufacturing of Implantable 3D-Printed Medical Devices

    PubMed Central

    Morrison, Robert J.; Kashlan, Khaled N.; Flanangan, Colleen L.; Wright, Jeanne K.; Green, Glenn E.; Hollister, Scott J.; Weatherwax, Kevin J.

    2015-01-01

    Three-dimensional (3D) printing, or additive manufacturing, technology has rapidly penetrated the medical device industry over the past several years, and innovative groups have harnessed it to create devices with unique composition, structure, and customizability. These distinctive capabilities afforded by 3D printing have introduced new regulatory challenges. The customizability of 3D-printed devices introduces new complexities when drafting a design control model for FDA consideration of market approval. The customizability and unique build processes of 3D-printed medical devices pose unique challenges in meeting regulatory standards related to the manufacturing quality assurance. Consistent material powder properties and optimal printing parameters such as build orientation and laser power must be addressed and communicated to the FDA to ensure a quality build. Post-printing considerations unique to 3D-printed devices, such as cleaning, finishing and sterilization are also discussed. In this manuscript we illustrate how such regulatory hurdles can be navigated by discussing our experience with our group’s 3D-printed bioresorbable implantable device. PMID:26243449

  6. Regulatory Considerations in the Design and Manufacturing of Implantable 3D-Printed Medical Devices.

    PubMed

    Morrison, Robert J; Kashlan, Khaled N; Flanangan, Colleen L; Wright, Jeanne K; Green, Glenn E; Hollister, Scott J; Weatherwax, Kevin J

    2015-10-01

    Three-dimensional (3D) printing, or additive manufacturing, technology has rapidly penetrated the medical device industry over the past several years, and innovative groups have harnessed it to create devices with unique composition, structure, and customizability. These distinctive capabilities afforded by 3D printing have introduced new regulatory challenges. The customizability of 3D-printed devices introduces new complexities when drafting a design control model for FDA consideration of market approval. The customizability and unique build processes of 3D-printed medical devices pose unique challenges in meeting regulatory standards related to the manufacturing quality assurance. Consistent material powder properties and optimal printing parameters such as build orientation and laser power must be addressed and communicated to the FDA to ensure a quality build. Postprinting considerations unique to 3D-printed devices, such as cleaning, finishing and sterilization are also discussed. In this manuscript we illustrate how such regulatory hurdles can be navigated by discussing our experience with our group's 3D-printed bioresorbable implantable device.

  7. Staining and embedding of human chromosomes for 3-d serial block-face scanning electron microscopy.

    PubMed

    Yusuf, Mohammed; Chen, Bo; Hashimoto, Teruo; Estandarte, Ana Katrina; Thompson, George; Robinson, Ian

    2014-12-01

    The high-order structure of human chromosomes is an important biological question that is still under investigation. Studies have been done on imaging human mitotic chromosomes using mostly 2-D microscopy methods. To image micron-sized human chromosomes in 3-D, we developed a procedure for preparing samples for serial block-face scanning electron microscopy (SBFSEM). Polyamine chromosomes are first separated using a simple filtration method and then stained with heavy metal. We show that the DNA-specific platinum blue provides higher contrast than osmium tetroxide. A two-step procedure for embedding chromosomes in resin is then used to concentrate the chromosome samples. After stacking the SBFSEM images, a familiar X-shaped chromosome was observed in 3-D.

  8. A case of pulmonary artery intimal sarcoma diagnosed with multislice CT scan with 3D reconstruction.

    PubMed

    Choi, Eui-Young; Yoon, Young-Won; Kwon, Hyuck Moon; Kim, Dongsoo; Park, Byung-Eun; Hong, Yoo-Sun; Koo, Ja-Seung; Kim, Tae-Hoon; Kim, Hyun-Seung

    2004-06-30

    Pulmonary artery intimal sarcoma is a rare highly lethal disease, with additional retrograde extension to pulmonic valve and right ventricle being an extremely rare condition. It is frequently mistaken for pulmonary thromboembolism. We report a case of 64-year-old woman with progressive dyspnea initially suspected and treated for pulmonary thromboembolism. Her helical chest CT scan with 3 dimensional (3D) reconstruction combined with echocardiography revealed a compacting main pulmonary artery mass extending to the right ventricular outflow tract and the right pulmonary artery. After excision of the mass, the patient's condition improved dramatically, and the pathologic findings revealed pulmonary intimal sarcoma. This report emphasizes that helical chest CT with 3D reconstruction can be an important tool to differentiate the characteristics of pulmonary artery lesions, such as intimal sarcoma and thromboembolism.

  9. Interactive algorithms for the segmentation and quantitation of 3-D MRI brain scans.

    PubMed

    Freeborough, P A; Fox, N C; Kitney, R I

    1997-05-01

    Interactive algorithms are an attractive approach to the accurate segmentation of 3D brain scans as they potentially improve the reliability of fully automated segmentation while avoiding the labour intensiveness and inaccuracies of manual segmentation. We present a 3D image analysis package (MIDAS) with a novel architecture enabling highly interactive segmentation algorithms to be implemented as add on modules. Interactive methods based on intensity thresholding, region growing and the constrained application of morphological operators are also presented. The methods involve the application of constraints and freedoms on the algorithms coupled with real time visualisation of the effect. This methodology has been applied to the segmentation, visualisation and measurement of the whole brain and a small irregular neuroanatomical structure, the hippocampus. We demonstrate reproducible and anatomically accurate segmentations of these structures. The efficacy of one method in measuring volume loss (atrophy) of the hippocampus in Alzheimer's disease is shown and is compared to conventional methods.

  10. Robust Locally Weighted Regression For Ground Surface Extraction In Mobile Laser Scanning 3D Data

    NASA Astrophysics Data System (ADS)

    Nurunnabi, A.; West, G.; Belton, D.

    2013-10-01

    A new robust way for ground surface extraction from mobile laser scanning 3D point cloud data is proposed in this paper. Fitting polynomials along 2D/3D points is one of the well-known methods for filtering ground points, but it is evident that unorganized point clouds consist of multiple complex structures by nature so it is not suitable for fitting a parametric global model. The aim of this research is to develop and implement an algorithm to classify ground and non-ground points based on statistically robust locally weighted regression which fits a regression surface (line in 2D) by fitting without any predefined global functional relation among the variables of interest. Afterwards, the z (elevation)-values are robustly down weighted based on the residuals for the fitted points. The new set of down weighted z-values along with x (or y) values are used to get a new fit of the (lower) surface (line). The process of fitting and down-weighting continues until the difference between two consecutive fits is insignificant. Then the final fit represents the ground level of the given point cloud and the ground surface points can be extracted. The performance of the new method has been demonstrated through vehicle based mobile laser scanning 3D point cloud data from urban areas which include different problematic objects such as short walls, large buildings, electric poles, sign posts and cars. The method has potential in areas like building/construction footprint determination, 3D city modelling, corridor mapping and asset management.

  11. 3-D ultrasonic strain imaging based on a linear scanning system.

    PubMed

    Huang, Qinghua; Xie, Bo; Ye, Pengfei; Chen, Zhaohong

    2015-02-01

    This paper introduces a 3-D strain imaging method based on a freehand linear scanning mode. We designed a linear sliding track with a position sensor and a height-adjustable holder to constrain the movement of an ultrasound probe in a freehand manner. When moving the probe along the sliding track, the corresponding positional measures for the probe are transmitted via a wireless communication module based on Bluetooth in real time. In a single examination, the probe is scanned in two sweeps in which the height of the probe is adjusted by the holder to collect the pre- and postcompression radio-frequency echoes, respectively. To generate a 3-D strain image, a volume cubic in which the voxels denote relative strains for tissues is defined according to the range of the two sweeps. With respect to the post-compression frames, several slices in the volume are determined and the pre-compression frames are re-sampled to precisely correspond to the post-compression frames. Thereby, a strain estimation method based on minimizing a cost function using dynamic programming is used to obtain the 2-D strain image for each pair of frames from the re-sampled pre-compression sweep and the post-compression sweep, respectively. A software system is developed for volume reconstruction, visualization, and measurement of the 3-D strain images. The experimental results show that high-quality 3-D strain images of phantom and human tissues can be generated by the proposed method, indicating that the proposed system can be applied for real clinical applications (e.g., musculoskeletal assessments).

  12. Robust automatic measurement of 3D scanned models for the human body fat estimation.

    PubMed

    Giachetti, Andrea; Lovato, Christian; Piscitelli, Francesco; Milanese, Chiara; Zancanaro, Carlo

    2015-03-01

    In this paper, we present an automatic tool for estimating geometrical parameters from 3-D human scans independent on pose and robustly against the topological noise. It is based on an automatic segmentation of body parts exploiting curve skeleton processing and ad hoc heuristics able to remove problems due to different acquisition poses and body types. The software is able to locate body trunk and limbs, detect their directions, and compute parameters like volumes, areas, girths, and lengths. Experimental results demonstrate that measurements provided by our system on 3-D body scans of normal and overweight subjects acquired in different poses are highly correlated with the body fat estimates obtained on the same subjects with dual-energy X-rays absorptiometry (DXA) scanning. In particular, maximal lengths and girths, not requiring precise localization of anatomical landmarks, demonstrate a good correlation (up to 96%) with the body fat and trunk fat. Regression models based on our automatic measurements can be used to predict body fat values reasonably well.

  13. An architecture for integrating planar and 3D cQED devices

    NASA Astrophysics Data System (ADS)

    Axline, C.; Reagor, M.; Heeres, R.; Reinhold, P.; Wang, C.; Shain, K.; Pfaff, W.; Chu, Y.; Frunzio, L.; Schoelkopf, R. J.

    2016-07-01

    Numerous loss mechanisms can limit coherence and scalability of planar and 3D-based circuit quantum electrodynamics (cQED) devices, particularly due to their packaging. The low loss and natural isolation of 3D enclosures make them good candidates for coherent scaling. We introduce a coaxial transmission line device architecture with coherence similar to traditional 3D cQED systems. Measurements demonstrate well-controlled external and on-chip couplings, a spectrum absent of cross-talk or spurious modes, and excellent resonator and qubit lifetimes. We integrate a resonator-qubit system in this architecture with a seamless 3D cavity, and separately pattern a qubit, readout resonator, Purcell filter, and high-Q stripline resonator on a single chip. Device coherence and its ease of integration make this a promising tool for complex experiments.

  14. Diagnostic Capability of Peripapillary Retinal Thickness in Glaucoma Using 3D Volume Scans

    PubMed Central

    Simavli, Huseyin; Que, Christian John; Akduman, Mustafa; Rizzo, Jennifer L.; Tsikata, Edem; de Boer, Johannes F.; Chen, Teresa C.

    2015-01-01

    Purpose To determine the diagnostic capability of spectral domain optical coherence tomography (SD-OCT) peripapillary retinal thickness (RT) measurements from 3-dimensional (3D) volume scans for primary open angle glaucoma (POAG). Design Cross-sectional study. Methods Setting Institutional Study population 156 patients (89 POAG and 67 normal subjects) Observation procedures One eye of each subject was included. SD-OCT peripapillary RT values from 3D volume scans were calculated for four quadrants of three different sized annuli. Peripapillary retinal nerve fiber layer (RNFL) thickness values were also determined. Main outcome measures Area under the receiver operating characteristic curve (AUROC) values, sensitivity, specificity, positive and negative predictive values, and positive and negative likelihood ratios. Results The top five RT AUROCs for all glaucoma patients and for a subset of early glaucoma patients were for the inferior quadrant of outer circumpapillary annulus of circular grid (OCA) 1 (0.959, 0.939), inferior quadrant of OCA2 (0.945, 0.921), superior quadrant of OCA1 (0.890, 0.811), inferior quadrant of OCA3 (0.887, 0.854), and superior quadrant of OCA2 (0.879, 0.807). Smaller RT annuli OCA1 and OCA2 consistently showed better diagnostic performance than the larger RT annulus OCA3. For both RNFL and RT measurements, best AUROC values were found for inferior RT OCA1 and OCA2, followed by inferior and overall RNFL thickness. Conclusion Peripapillary RT measurements from 3D volume scans showed excellent diagnostic performance for detecting both glaucoma and early glaucoma patients. Peripapillary RT values have the same or better diagnostic capability compared to peripapillary RNFL thickness measurements, while also having fewer algorithm errors. PMID:25498354

  15. Optimization of 3D laser scanning speed by use of combined variable step

    NASA Astrophysics Data System (ADS)

    Garcia-Cruz, X. M.; Sergiyenko, O. Yu.; Tyrsa, Vera; Rivas-Lopez, M.; Hernandez-Balbuena, D.; Rodriguez-Quiñonez, J. C.; Basaca-Preciado, L. C.; Mercorelli, P.

    2014-03-01

    The problem of 3D TVS slow functioning caused by constant small scanning step becomes its solution in the presented research. It can be achieved by combined scanning step application for the fast search of n obstacles in unknown surroundings. Such a problem is of keynote importance in automatic robot navigation. To maintain a reasonable speed robots must detect dangerous obstacles as soon as possible, but all known scanners able to measure distances with sufficient accuracy are unable to do it in real time. So, the related technical task of the scanning with variable speed and precise digital mapping only for selected spatial sectors is under consideration. A wide range of simulations in MATLAB 7.12.0 of several variants of hypothetic scenes with variable n obstacles in each scene (including variation of shapes and sizes) and scanning with incremented angle value (0.6° up to 15°) is provided. The aim of such simulation was to detect which angular values of interval still permit getting the maximal information about obstacles without undesired time losses. Three of such local maximums were obtained in simulations and then rectified by application of neuronal network formalism (Levenberg-Marquradt Algorithm). The obtained results in its turn were applied to MET (Micro-Electro-mechanical Transmission) design for practical realization of variable combined step scanning on an experimental prototype of our previously known laser scanner.

  16. Point scanning confocal microscopy facilitates 3D human hair follicle imaging in tissue sections.

    PubMed

    Kloepper, Jennifer E; Bíró, Tamás; Paus, Ralf; Cseresnyés, Zoltán

    2010-07-01

    Efficiency is a key factor in determining whether a scientific method becomes widely accepted in practical applications. In dermatology, morphological characterisation of intact hair follicles by traditional methods can be rather inefficient. Samples are embedded, sliced, imaged and digitally reconstructed, which can be time-consuming. Confocal microscopy, on the other hand, is more efficient and readily applicable to study intact hair follicles. Modern confocal microscopes deliver and collect light very efficiently and thus allow high spatial resolution imaging of relatively thick samples. In this letter, we report that we successfully imaged entire intact human hair follicles using point scanning confocal microscopy. Light delivery and light-collection were further improved by preparing the samples in 2,2'-Thiodiethanol (TDE), thus reducing refractive index gradients. The relatively short total scan times and the high quality of the acquired 3D images make confocal microscopy a desirable method for studying intact hair follicles under normal and pathological conditions.

  17. Mitigation of Tracheobronchomalacia with 3D-Printed Personalized Medical Devices in Pediatric Patients

    PubMed Central

    Morrison, Robert J.; Hollister, Scott J.; Niedner, Matthew F.; Mahani, Maryam Ghadimi; Park, Albert H.; Mehta, Deepak K.; Ohye, Richard G.; Green, Glenn E.

    2015-01-01

    Three-dimensional (3D) printing offers the potential for rapid customization of medical devices. The advent of 3D-printable biomaterials has created the potential for device control in the fourth dimension: 3D-printed objects that exhibit a designed shape change under tissue growth and resorption conditions over time. Tracheobronchomalacia (TBM) is a condition of excessive collapse of the airways during respiration that can lead to life-threatening cardiopulmonary arrests. Here we demonstrate the successful application of 3D printing technology to produce a personalized medical device for treatment of TBM, designed to accommodate airway growth while preventing external compression over a pre-determined time period before bioresorption. We implanted patient-specific 3D-printed external airway splints in three infants with severe TBM. At the time of publication, these infants no longer exhibited life-threatening airway disease and had demonstrated resolution of both pulmonary and extra-pulmonary complications of their TBM. Long-term data show continued growth of the primary airways. This process has broad application for medical manufacturing of patient-specific 3D-printed devices that adjust to tissue growth through designed mechanical and degradation behaviors over time. PMID:25925683

  18. Mitigation of tracheobronchomalacia with 3D-printed personalized medical devices in pediatric patients.

    PubMed

    Morrison, Robert J; Hollister, Scott J; Niedner, Matthew F; Mahani, Maryam Ghadimi; Park, Albert H; Mehta, Deepak K; Ohye, Richard G; Green, Glenn E

    2015-04-29

    Three-dimensional (3D) printing offers the potential for rapid customization of medical devices. The advent of 3D-printable biomaterials has created the potential for device control in the fourth dimension: 3D-printed objects that exhibit a designed shape change under tissue growth and resorption conditions over time. Tracheobronchomalacia (TBM) is a condition of excessive collapse of the airways during respiration that can lead to life-threatening cardiopulmonary arrests. We demonstrate the successful application of 3D printing technology to produce a personalized medical device for treatment of TBM, designed to accommodate airway growth while preventing external compression over a predetermined time period before bioresorption. We implanted patient-specific 3D-printed external airway splints in three infants with severe TBM. At the time of publication, these infants no longer exhibited life-threatening airway disease and had demonstrated resolution of both pulmonary and extrapulmonary complications of their TBM. Long-term data show continued growth of the primary airways. This process has broad application for medical manufacturing of patient-specific 3D-printed devices that adjust to tissue growth through designed mechanical and degradation behaviors over time.

  19. Error Analysis of Terrestrial Laser Scanning Data by Means of Spherical Statistics and 3D Graphs

    PubMed Central

    Cuartero, Aurora; Armesto, Julia; Rodríguez, Pablo G.; Arias, Pedro

    2010-01-01

    This paper presents a complete analysis of the positional errors of terrestrial laser scanning (TLS) data based on spherical statistics and 3D graphs. Spherical statistics are preferred because of the 3D vectorial nature of the spatial error. Error vectors have three metric elements (one module and two angles) that were analyzed by spherical statistics. A study case has been presented and discussed in detail. Errors were calculating using 53 check points (CP) and CP coordinates were measured by a digitizer with submillimetre accuracy. The positional accuracy was analyzed by both the conventional method (modular errors analysis) and the proposed method (angular errors analysis) by 3D graphics and numerical spherical statistics. Two packages in R programming language were performed to obtain graphics automatically. The results indicated that the proposed method is advantageous as it offers a more complete analysis of the positional accuracy, such as angular error component, uniformity of the vector distribution, error isotropy, and error, in addition the modular error component by linear statistics. PMID:22163461

  20. 3D Imaging of Diatoms with Ion-abrasion Scanning Electron Microscopy

    PubMed Central

    Hildebrand, Mark; Kim, Sang; Shi, Dan; Scott, Keana; Subramaniam, Sriram

    2009-01-01

    Ion-abrasion scanning electron microscopy (IASEM) takes advantage of focused ion beams to abrade thin sections from the surface of bulk specimens, coupled with SEM to image the surface of each section, enabling 3D reconstructions of subcellular architecture at ~ 30 nm resolution. Here, we report the first application of IASEM for imaging a biomineralizing organism, the marine diatom Thalassiosira pseudonana. Diatoms have highly patterned silica-based cell wall structures that are unique models for the study and application of directed nanomaterials synthesis by biological systems. Our study provides new insights into the architecture and assembly principles of both the “hard” (siliceous) and “soft” (organic) components of the cell. From 3D reconstructions of developmentally synchronized diatoms captured at different stages, we show that both micro- and nanoscale siliceous structures can be visualized at specific stages in their formation. We show that not only are structures visualized in a whole-cell context, but demonstrate that fragile, early-stage structures are visible, and that this can be combined with elemental mapping in the exposed slice. We demonstrate that the 3D architectures of silica structures, and the cellular components that mediate their creation and positioning can be visualized simultaneously, providing new opportunities to study and manipulate mineral nanostructures in a genetically tractable system. PMID:19269330

  1. Topographical surveys: Classical method versus 3D laser scanning. Case study - An application in civil engineering

    NASA Astrophysics Data System (ADS)

    Grigoraş, I.-R.; Covăsnianu, A.; Pleşu, G.; Benedict, B.

    2009-04-01

    The paper describes an experiment which took place in Iasi town, Romania, consisted in two different topographical survey techniques applied for one and the same objective placed in a block within the city (western part) - a thermal power station. The purpose was to compare those methods and to determine which one is proper to be used in this domain in terms of fastness, optimization and speed of data processing. First technique applied for our survey was the classical one, with a total station. Using the CAD technique, we obtained a final product (a dwg file) and a list of coordinates (a text file). The second method, which we focused our attention more, was the measurement with a very precise 3D laser scanstation, also very suitable in archeology. The data obtained were processed with special software. Result was a 3D model of the thermal power plant composed of measurable cloud point data. Finally, analyzing the advantages and disadvantages of each method, we came to the conclusion that the 3D laser scanning which we used matches well the application, in this case civil engineering, but the future of accepting and implementing this technique is in the hands of Romanian authorities.

  2. Geoarchaeological site documentation and analysis of 3D data derived by terrestrial laser scanning

    NASA Astrophysics Data System (ADS)

    Hoffmeister, D.; Zellmann, S.; Kindermann, K.; Pastoors, A.; Lang, U.; Bubenzer, O.; Weniger, G.-C.; Bareth, G.

    2014-05-01

    Terrestrial laser scanning was conducted to document and analyse sites of geoarchaeological interest in Jordan, Egypt and Spain. In those cases, the terrestrial laser scanner LMS-Z420i from Riegl was used in combination with an accurate RTK-GPS for georeferencing of the point clouds. Additionally, local surveying networks were integrated by established transformations and used for indirect registration purposes. All data were integrated in a workflow that involves different software and according results. The derived data were used for the documentation of the sites by accurate plans and cross-sections. Furthermore, the 3D data were analysed for geoarchaeological research problems, such as volumetric determinations, the ceiling thickness of a cave and lighting simulations based on path tracing. The method was reliable in harsh environmental conditions, but the weight of the instrument, the measuring time and the minimum measurement distance were a drawback. However, generally an accurate documentation of the sites was possible. Overall, the integration in a 3D GIS is easily possible by the accurate georeference of the derived data. In addition, local survey results are also implemented by the established transformations. Enhanced analyses based on the derived 3D data shows promising results.

  3. 3-D micro surface profilometry employing novel Mirau-based lateral scanning interferometry

    NASA Astrophysics Data System (ADS)

    Chen, Liang-Chia; Le, Manh-Trung; Lin, Yi-Shiuan

    2014-09-01

    An innovative 3-D surface imaging methodology for reconstructing micro surface profiles with a long depth measuring range and a nano-scale resolution was developed using the newly developed Mirau-based lateral scanning interferometry (LSI). The current measuring field of view (FOV) of conventional white light interferometers is limited by microscopic views of the existing interferometric objectives, such as those in Michelson, Mirau or Linnik designs. Moreover, the vertical scanning operation required for acquiring volumetric interferometric data is extremely time-consuming and makes white light vertical scanning interferometry (VSI) infeasible for automatic optical inspection (AOI) of micro 3-D structures. To resolve this, a newly developed white light LSI method based on Mirau’s optical configuration was developed by controlling the tilting angle of the reference mirror in the Mirau interferometric objective. With the proposed optical configuration, the surface is inspected at a tilting angle with respect to the maximum coherence plane of the interferometric system along its lateral scanning direction when the objective lies perpendicular to the tested surface. In addition, a system calibration method was developed to establish an accurate mathematical mapping model between the object depth and the lateral axis. To evaluate the feasibility of the methodology, a calibrated step height was measured for evaluating the accuracy and repeatability. Some industrial samples, such as photon spacers and other microstructures fabricated by nano-imprinting processes, were measured to verify the actual performance on real components. It was found that the measurement repeatability was controlled less than 60 nm within one standard deviation for a maximum measurable depth of 27.21 µm.

  4. Robust statistical approaches for local planar surface fitting in 3D laser scanning data

    NASA Astrophysics Data System (ADS)

    Nurunnabi, Abdul; Belton, David; West, Geoff

    2014-10-01

    This paper proposes robust methods for local planar surface fitting in 3D laser scanning data. Searching through the literature revealed that many authors frequently used Least Squares (LS) and Principal Component Analysis (PCA) for point cloud processing without any treatment of outliers. It is known that LS and PCA are sensitive to outliers and can give inconsistent and misleading estimates. RANdom SAmple Consensus (RANSAC) is one of the most well-known robust methods used for model fitting when noise and/or outliers are present. We concentrate on the recently introduced Deterministic Minimum Covariance Determinant estimator and robust PCA, and propose two variants of statistically robust algorithms for fitting planar surfaces to 3D laser scanning point cloud data. The performance of the proposed robust methods is demonstrated by qualitative and quantitative analysis through several synthetic and mobile laser scanning 3D data sets for different applications. Using simulated data, and comparisons with LS, PCA, RANSAC, variants of RANSAC and other robust statistical methods, we demonstrate that the new algorithms are significantly more efficient, faster, and produce more accurate fits and robust local statistics (e.g. surface normals), necessary for many point cloud processing tasks. Consider one example data set used consisting of 100 points with 20% outliers representing a plane. The proposed methods called DetRD-PCA and DetRPCA, produce bias angles (angle between the fitted planes with and without outliers) of 0.20° and 0.24° respectively, whereas LS, PCA and RANSAC produce worse bias angles of 52.49°, 39.55° and 0.79° respectively. In terms of speed, DetRD-PCA takes 0.033 s on average for fitting a plane, which is approximately 6.5, 25.4 and 25.8 times faster than RANSAC, and two other robust statistical methods, respectively. The estimated robust surface normals and curvatures from the new methods have been used for plane fitting, sharp feature

  5. Automated kidney detection for 3D ultrasound using scan line searching

    NASA Astrophysics Data System (ADS)

    Noll, Matthias; Nadolny, Anne; Wesarg, Stefan

    2016-04-01

    Ultrasound (U/S) is a fast and non-expensive imaging modality that is used for the examination of various anatomical structures, e.g. the kidneys. One important task for automatic organ tracking or computer-aided diagnosis is the identification of the organ region. During this process the exact information about the transducer location and orientation is usually unavailable. This renders the implementation of such automatic methods exceedingly challenging. In this work we like to introduce a new automatic method for the detection of the kidney in 3D U/S images. This novel technique analyses the U/S image data along virtual scan lines. Here, characteristic texture changes when entering and leaving the symmetric tissue regions of the renal cortex are searched for. A subsequent feature accumulation along a second scan direction produces a 2D heat map of renal cortex candidates, from which the kidney location is extracted in two steps. First, the strongest candidate as well as its counterpart are extracted by heat map intensity ranking and renal cortex size analysis. This process exploits the heat map gap caused by the renal pelvis region. Substituting the renal pelvis detection with this combined cortex tissue feature increases the detection robustness. In contrast to model based methods that generate characteristic pattern matches, our method is simpler and therefore faster. An evaluation performed on 61 3D U/S data sets showed, that in 55 cases showing none or minor shadowing the kidney location could be correctly identified.

  6. 3D surface scan of biological samples with a Push-broom Imaging Spectrometer

    NASA Astrophysics Data System (ADS)

    Yao, Haibo; Kincaid, Russell; Hruska, Zuzana; Brown, Robert L.; Bhatnagar, Deepak; Cleveland, Thomas E.

    2013-08-01

    The food industry is always on the lookout for sensing technologies for rapid and nondestructive inspection of food products. Hyperspectral imaging technology integrates both imaging and spectroscopy into unique imaging sensors. Its application for food safety and quality inspection has made significant progress in recent years. Specifically, hyperspectral imaging has shown its potential for surface contamination detection in many food related applications. Most existing hyperspectral imaging systems use pushbroom scanning which is generally used for flat surface inspection. In some applications it is desirable to be able to acquire hyperspectral images on circular objects such as corn ears, apples, and cucumbers. Past research describes inspection systems that examine all surfaces of individual objects. Most of these systems did not employ hyperspectral imaging. These systems typically utilized a roller to rotate an object, such as an apple. During apple rotation, the camera took multiple images in order to cover the complete surface of the apple. The acquired image data lacked the spectral component present in a hyperspectral image. This paper discusses the development of a hyperspectral imaging system for a 3-D surface scan of biological samples. The new instrument is based on a pushbroom hyperspectral line scanner using a rotational stage to turn the sample. The system is suitable for whole surface hyperspectral imaging of circular objects. In addition to its value to the food industry, the system could be useful for other applications involving 3-D surface inspection.

  7. Measuring Fracture Properties of Meteorites: 3D Scans and Disruption Experiments.

    NASA Astrophysics Data System (ADS)

    Cotto-Figueroa, Desireé; Asphaug, Erik; Morris, Melissa A.; Garvie, Laurence

    2014-11-01

    The Arizona State University (ASU) Center for Meteorite Studies (CMS) houses over 30,000 specimens that represent almost every known meteorite type. A number of these are available for fragmentation experiments in small samples, but in most cases non-destructive experiments are desired in order to determine the fundamental mechanical properties of meteorites, and by extension, the Near-Earth Asteroids (NEAs) and other planetary bodies they derive from. We present results from an ongoing suite of measurements and experiments, featuring automated 3D topographic scans of a comprehensive suite of meteorites in the CMS collection, basic mechanical studies, and culminating in catastrophic fragmentation of four representative meteorites: Tamdakht (H5), Allende (CV3), Northwest Africa 869 (L3-6) and Chelyabinsk (LL5). Results will include high-resolution 3D color-shape models of meteorites, including specimens such as the 349g oriented and fusion crusted Martian (shergottite) Tissint, and the delicately fusion crusted and oriented 131g Whetstone Mountains (H5) ordinary chondrite. The 3D color-shape models will allow us to obtain basic physical properties (such as volume to derive density) and to derive fractal dimensions of fractured surfaces. Fractal dimension is closely related to the internal structural heterogeneity and fragmentation of the material, to macroscopic optical properties, and to rubble friction and cohesion. Freshly fractured surfaces of fragments that will result from catastrophic hypervelocity impact experiments will be subsequently scanned and analyzed in order to determine whether fractal dimension is preserved or if it changes with surface maturation.

  8. Femtosecond laser fabricated electrofluidic devices in glass for 3D manipulation of biological samples

    NASA Astrophysics Data System (ADS)

    Xu, Jian; Midorikawa, Katsumi; Sugioka, Koji

    2016-03-01

    Novel electrofluidic microdevices based on monolithic integration of 3D metal electrodes into 3D glass microchannels have been prepared by femtosecond (fs) laser hybrid microfabrication. 3D microchannels with smooth internal walls are first prepared in photosensitive glass by fs laser-assisted chemical wet etching process combined with post-annealing. Then, 3D electrode patterning in prepared glass channels is carried out by water-assisted fs-laser direct-write ablation using the same laser followed by electroless metal plating. Laser processing parameters are optimized and the roles of water during the laser irradiation are discussed. The fabricated electrofluidic devices are applied to demonstrate 3D electro-orientation of cells in microfluidic environments.

  9. 3-D water vapor field in the atmospheric boundary layer observed with scanning differential absorption lidar

    NASA Astrophysics Data System (ADS)

    Späth, Florian; Behrendt, Andreas; Muppa, Shravan Kumar; Metzendorf, Simon; Riede, Andrea; Wulfmeyer, Volker

    2016-04-01

    High-resolution three-dimensional (3-D) water vapor data of the atmospheric boundary layer (ABL) are required to improve our understanding of land-atmosphere exchange processes. For this purpose, the scanning differential absorption lidar (DIAL) of the University of Hohenheim (UHOH) was developed as well as new analysis tools and visualization methods. The instrument determines 3-D fields of the atmospheric water vapor number density with a temporal resolution of a few seconds and a spatial resolution of up to a few tens of meters. We present three case studies from two field campaigns. In spring 2013, the UHOH DIAL was operated within the scope of the HD(CP)2 Observational Prototype Experiment (HOPE) in western Germany. HD(CP)2 stands for High Definition of Clouds and Precipitation for advancing Climate Prediction and is a German research initiative. Range-height indicator (RHI) scans of the UHOH DIAL show the water vapor heterogeneity within a range of a few kilometers up to an altitude of 2 km and its impact on the formation of clouds at the top of the ABL. The uncertainty of the measured data was assessed for the first time by extending a technique to scanning data, which was formerly applied to vertical time series. Typically, the accuracy of the DIAL measurements is between 0.5 and 0.8 g m-3 (or < 6 %) within the ABL even during daytime. This allows for performing a RHI scan from the surface to an elevation angle of 90° within 10 min. In summer 2014, the UHOH DIAL participated in the Surface Atmosphere Boundary Layer Exchange (SABLE) campaign in southwestern Germany. Conical volume scans were made which reveal multiple water vapor layers in three dimensions. Differences in their heights in different directions can be attributed to different surface elevation. With low-elevation scans in the surface layer, the humidity profiles and gradients can be related to different land cover such as maize, grassland, and forest as well as different surface layer

  10. Electrochemical fields within 3D reconstructed microstructures of mixed ionic and electronic conducting devices

    NASA Astrophysics Data System (ADS)

    Zhang, Yanxiang; Chen, Yu; Lin, Ye; Yan, Mufu; Harris, William M.; Chiu, Wilson K. S.; Ni, Meng; Chen, Fanglin

    2016-11-01

    The performance and stability of the mixed ionic and electronic conducting (MIEC) membrane devices, such as solid oxide cells (SOCs) and oxygen separation membranes (OSMs) interplay tightly with the transport properties and the three-dimensional (3D) microstructure of the membrane. However, development of the MIEC devices is hindered by the limited knowledge about the distribution of electrochemical fields within the 3D local microstructures, especially at surface and interface. In this work, a generic model conforming to local thermodynamic equilibrium is developed to calculate the electrochemical fields, such as electric potential and oxygen chemical potential, within the 3D microstructure of the MIEC membrane. Stability of the MIEC membrane is evaluated by the distribution of oxygen partial pressure. The cell-level performance such as polarization resistance and voltage vs. current curve can be further calculated. Case studies are performed to demonstrate the capability of the framework by using X-ray computed tomography reconstructed 3D microstructures of a SOC and an OSM. The calculation method demonstrates high computational efficiency for large size 3D tomographic microstructures, and permits parallel calculation. The framework can serve as a powerful tool for correlating the transport properties and the 3D microstructure to the performance and the stability of MIEC devices.

  11. Confocal laser scanning microscopy and 3-D reconstructions of neuronal structures in human brain cortex.

    PubMed

    Belichenko, P V; Dahlström, A

    1995-09-01

    Human brain material was studied with Lucifer yellow (LY) microinjections, indirect Texas red immunofluorescence, and confocal laser scanning microscopy (CLSM). The scanned images were transferred to a Silicon Graphics (SG) IRIS computer equipped with software for reconstructing the 3-D architecture of cells. By employing dual channel CLSM (Bio-Rad MRC 600), LY-injected cells and Texas red immunofluorescence could be studied simultaneously. Autopsy material with 2- to 48-h postmortem delays (6 control and 2 Rett's syndrome cases) as well as biopsy material (14 cases with therapy-resistant partial epilepsy--TRPE--undergoing neurosurgery) were used. In each specimen, 100-200 pyramidal and nonpyramidal neurons were visualized by LY microinjection. Single neurons were imaged and 2-D reconstructions of each neuron were made using z-projections of serial optical images; 3-D reconstructions and rotations were computed using the SG workstation, with VoxelView software from Vital Images (UK), and stored in a "neuronal library" on laser or magnetic optical disks. In Ret's syndrome cases and in patients with TRPE various abnormalities in the dendritic geometry of pyramidal and nonpyramidal cells have been found. The combination of LY injections with immunofluorescence allows the investigation of transmitter-related substances around the LY-injected cells. Using antibodies to synaptic vesicle proteins, presynaptic elements docking onto individual spines have been demonstrated. This approach may contribute to the understanding of different neurological and psychiatric disorders and may be useful in the Mapping of the Human Brain project. It may also be integrated with functional imaging by PET scan and with the human genome project.

  12. Microchip-Based Electrochemical Detection using a 3-D Printed Wall-Jet Electrode Device

    PubMed Central

    Munshi, Akash S.; Martin, R. Scott

    2016-01-01

    Three dimensional (3-D) printing technology has evolved dramatically in the last few years, offering the capability of printing objects with a variety of materials. Printing microfluidic devices using this technology offers various advantages such as ease and uniformity of fabrication, file sharing between laboratories, and increased device-to-device reproducibility. One unique aspects of this technology, when used with electrochemical detection, is the ability to produce a microfluidic device as one unit while also allowing the reuse of the device and electrode for multiple analyses. Here we present an alternate electrode configuration for microfluidic devices, a wall-jet electrode (WJE) approach, created by 3-D printing. Using microchip-based flow injection analysis, we compared the WJE design with the conventionally used thin-layer electrode (TLE) design. It was found that the optimized WJE system enhances analytical performance (as compared to the TLE design), with improvements in sensitivity and the limit of detection. Experiments were conducted using two working electrodes – 500 μm platinum and 1 mm glassy carbon. Using the 500 μm platinum electrode the calibration sensitivity was 16 times higher for the WJE device (as compared to the TLE design). In addition, use of the 1 mm glassy carbon electrode led to limit of detection of 500 nM for catechol, as compared to 6 μM for the TLE device. Finally, to demonstrate the versatility and applicability of the 3-D printed WJE approach, the device was used as an inexpensive electrochemical detector for HPLC. The number of theoretical plates was comparable to the use of commercially available UV and MS detectors, with the WJE device being inexpensive to utilize. These results show that 3D-printing can be a powerful tool to fabricate reusable and integrated microfluidic detectors in configurations that are not easily achieved with more traditional lithographic methods. PMID:26649363

  13. 3D Printing of Medicines: Engineering Novel Oral Devices with Unique Design and Drug Release Characteristics.

    PubMed

    Goyanes, Alvaro; Wang, Jie; Buanz, Asma; Martínez-Pacheco, Ramón; Telford, Richard; Gaisford, Simon; Basit, Abdul W

    2015-11-02

    Three dimensional printing (3D printing) was used to fabricate novel oral drug delivery devices with specialized design configurations. Each device was loaded with multiple actives, with the intent of applying this process to the production of personalized medicines tailored at the point of dispensing or use. A filament extruder was used to obtain drug-loaded--paracetamol (acetaminophen) or caffeine--filaments of poly(vinyl alcohol) with characteristics suitable for use in fused-deposition modeling 3D printing. A multinozzle 3D printer enabled fabrication of capsule-shaped solid devices containing the drug with different internal structures. The design configurations included a multilayer device, with each layer containing drug, whose identity was different to the drug in the adjacent layers, and a two-compartment device comprising a caplet embedded within a larger caplet (DuoCaplet), with each compartment containing a different drug. Raman spectroscopy was used to collect 2-dimensional hyper spectral arrays across the entire surface of the devices. Processing of the arrays using direct classical least-squares component matching to produce false color representations of distribution of the drugs was used. This clearly showed a definitive separation between the drug layers of paracetamol and caffeine. Drug release tests in biorelevant bicarbonate media showed unique drug release profiles dependent on the macrostructure of the devices. In the case of the multilayer devices, release of both paracetamol and caffeine was simultaneous and independent of drug solubility. With the DuoCaplet design, it was possible to engineer either rapid drug release or delayed release by selecting the site of incorporation of the drug in the device; the lag-time for release from the internal compartment was dependent on the characteristics of the external layer. The study confirms the potential of 3D printing to fabricate multiple-drug containing devices with specialized design

  14. Microchip-based electrochemical detection using a 3-D printed wall-jet electrode device.

    PubMed

    Munshi, Akash S; Martin, R Scott

    2016-02-07

    Three dimensional (3-D) printing technology has evolved dramatically in the last few years, offering the capability of printing objects with a variety of materials. Printing microfluidic devices using this technology offers various advantages such as ease and uniformity of fabrication, file sharing between laboratories, and increased device-to-device reproducibility. One unique aspect of this technology, when used with electrochemical detection, is the ability to produce a microfluidic device as one unit while also allowing the reuse of the device and electrode for multiple analyses. Here we present an alternate electrode configuration for microfluidic devices, a wall-jet electrode (WJE) approach, created by 3-D printing. Using microchip-based flow injection analysis, we compared the WJE design with the conventionally used thin-layer electrode (TLE) design. It was found that the optimized WJE system enhances analytical performance (as compared to the TLE design), with improvements in sensitivity and the limit of detection. Experiments were conducted using two working electrodes - 500 μm platinum and 1 mm glassy carbon. Using the 500 μm platinum electrode the calibration sensitivity was 16 times higher for the WJE device (as compared to the TLE design). In addition, use of the 1 mm glassy carbon electrode led to limit of detection of 500 nM for catechol, as compared to 6 μM for the TLE device. Finally, to demonstrate the versatility and applicability of the 3-D printed WJE approach, the device was used as an inexpensive electrochemical detector for HPLC. The number of theoretical plates was comparable to the use of commercially available UV and MS detectors, with the WJE device being inexpensive to utilize. These results show that 3-D-printing can be a powerful tool to fabricate reusable and integrated microfluidic detectors in configurations that are not easily achieved with more traditional lithographic methods.

  15. Shape Analysis of 3D Head Scan Data for U.S. Respirator Users

    NASA Astrophysics Data System (ADS)

    Zhuang, Ziqing; Slice, DennisE; Benson, Stacey; Lynch, Stephanie; Viscusi, DennisJ

    2010-12-01

    In 2003, the National Institute for Occupational Safety and Health (NIOSH) conducted a head-and-face anthropometric survey of diverse, civilian respirator users. Of the 3,997 subjects measured using traditional anthropometric techniques, surface scans and 26 three-dimensional (3D) landmark locations were collected for 947 subjects. The objective of this study was to report the size and shape variation of the survey participants using the 3D data. Generalized Procrustes Analysis (GPA) was conducted to standardize configurations of landmarks associated with individuals into a common coordinate system. The superimposed coordinates for each individual were used as commensurate variables that describe individual shape and were analyzed using Principal Component Analysis (PCA) to identify population variation. The first four principal components (PC) account for 49% of the total sample variation. The first PC indicates that overall size is an important component of facial variability. The second PC accounts for long and narrow or short and wide faces. Longer narrow orbits versus shorter wider orbits can be described by PC3, and PC4 represents variation in the degree of ortho/prognathism. Geometric Morphometrics provides a detailed and interpretable assessment of morphological variation that may be useful in assessing respirators and devising new test and certification standards.

  16. The study of craniofacial growth patterns using 3D laser scanning and geometric morphometrics

    NASA Astrophysics Data System (ADS)

    Friess, Martin

    2006-02-01

    Throughout childhood, braincase and face grow at different rates and therefore exhibit variable proportions and positions relative to each other. Our understanding of the direction and magnitude of these growth patterns is crucial for many ergonomic applications and can be improved by advanced 3D morphometrics. The purpose of this study is to investigate this known growth allometry using 3D imaging techniques. The geometry of the head and face of 840 children, aged 2 to 19, was captured with a laser surface scanner and analyzed statistically. From each scan, 18 landmarks were extracted and registered using General Procrustes Analysis (GPA). GPA eliminates unwanted variation due to position, orientation and scale by applying a least-squares superimposition algorithm to individual landmark configurations. This approach provides the necessary normalization for the study of differences in size, shape, and their interaction (allometry). The results show that throughout adolescence, boys and girls follow a different growth trajectory, leading to marked differences not only in size but also in shape, most notably in relative proportions of the braincase. These differences can be observed during early childhood, but become most noticeable after the age of 13 years, when craniofacial growth in girls slows down significantly, whereas growth in boys continues for at least 3 more years.

  17. Development and Evaluation of Roadside/Obstacle Detection Method Using 3D Scanned Data Processing

    NASA Astrophysics Data System (ADS)

    Yamamoto, Hiroshi; Ishii, Yoshinori; Yamazaki, Katsuyuki

    In this paper, we have reported the development of a snowblower support system which can safely navigate snowblowers, even during a whiteout, with the combination of a very accurate GPS system, so called RTK-GPS, and a unique and highly accurate map of roadsides and obstacles on roads. Particularly emphasized new techniques in this paper are ways to detect accurate geographical positions of roadsides and obstacles by utilizing and analyzing 3D laser scanned data, whose data has become available in recent days. The experiment has shown that the map created by the methods and RTK-GPS can sufficiently navigate snowblowers, whereby a secure and pleasant social environment can be archived in snow areas of Japan. In addition, proposed methods are expected to be useful for other systems such as a quick development of a highly accurate road map, a safely navigation of a wheeled chair, and so on.

  18. Fast 3D visualization of endogenous brain signals with high-sensitivity laser scanning photothermal microscopy

    PubMed Central

    Miyazaki, Jun; Iida, Tadatsune; Tanaka, Shinji; Hayashi-Takagi, Akiko; Kasai, Haruo; Okabe, Shigeo; Kobayashi, Takayoshi

    2016-01-01

    A fast, high-sensitivity photothermal microscope was developed by implementing a spatially segmented balanced detection scheme into a laser scanning microscope. We confirmed a 4.9 times improvement in signal-to-noise ratio in the spatially segmented balanced detection compared with that of conventional detection. The system demonstrated simultaneous bi-modal photothermal and confocal fluorescence imaging of transgenic mouse brain tissue with a pixel dwell time of 20 μs. The fluorescence image visualized neurons expressing yellow fluorescence proteins, while the photothermal signal detected endogenous chromophores in the mouse brain, allowing 3D visualization of the distribution of various features such as blood cells and fine structures probably due to lipids. This imaging modality was constructed using compact and cost-effective laser diodes, and will thus be widely useful in the life and medical sciences. PMID:27231615

  19. Laser Scanning for 3D Object Characterization: Infrastructure for Exploration and Analysis of Vegetation Signatures

    NASA Astrophysics Data System (ADS)

    Koenig, K.; Höfle, B.

    2012-04-01

    Mapping and characterization of the three-dimensional nature of vegetation is increasingly gaining in importance. Deeper insight is required for e.g. forest management, biodiversity assessment, habitat analysis, precision agriculture, renewable energy production or the analysis of interaction between biosphere and atmosphere. However the potential of 3D vegetation characterization has not been exploited so far and new technologies are needed. Laser scanning has evolved into the state-of-the-art technology for highly accurate 3D data acquisition. By now several studies indicated a high value of 3D vegetation description by using laser data. The laser sensors provide a detailed geometric presentation (geometric information) of scanned objects as well as a full profile of laser energy that was scattered back to the sensor (radiometric information). In order to exploit the full potential of these datasets, profound knowledge on laser scanning technology for data acquisition, geoinformation technology for data analysis and object of interest (e.g. vegetation) for data interpretation have to be joined. A signature database is a collection of signatures of reference vegetation objects acquired under known conditions and sensor parameters and can be used to improve information extraction from unclassified vegetation datasets. Different vegetation elements (leaves, branches, etc.) at different heights above ground with different geometric composition contribute to the overall description (i.e. signature) of the scanned object. The developed tools allow analyzing tree objects according to single features (e.g. echo width and signal amplitude) and to any relation of features and derived statistical values (e.g. ratio of laser point attributes). For example, a single backscatter cross section value does not allow for tree species determination, whereas the average echo width per tree segment can give good estimates. Statistical values and/or distributions (e.g. Gaussian

  20. Customizable 3D Printed ‘Plug and Play’ Millifluidic Devices for Programmable Fluidics

    PubMed Central

    Tsuda, Soichiro; Jaffery, Hussain; Doran, David; Hezwani, Mohammad; Robbins, Phillip J.; Yoshida, Mari; Cronin, Leroy

    2015-01-01

    Three dimensional (3D) printing is actively sought after in recent years as a promising novel technology to construct complex objects, which scope spans from nano- to over millimeter scale. Previously we utilized Fused deposition modeling (FDM)-based 3D printer to construct complex 3D chemical fluidic systems, and here we demonstrate the construction of 3D milli-fluidic structures for programmable liquid handling and control of biological samples. Basic fluidic operation devices, such as water-in-oil (W/O) droplet generators for producing compartmentalized mono-disperse droplets, sensor-integrated chamber for online monitoring of cellular growth, are presented. In addition, chemical surface treatment techniques are used to construct valve-based flow selector for liquid flow control and inter-connectable modular devices for networking fluidic parts. As such this work paves the way for complex operations, such as mixing, flow control, and monitoring of reaction / cell culture progress can be carried out by constructing both passive and active components in 3D printed structures, which designs can be shared online so that anyone with 3D printers can reproduce them by themselves. PMID:26558389

  1. Customizable 3D Printed 'Plug and Play' Millifluidic Devices for Programmable Fluidics.

    PubMed

    Tsuda, Soichiro; Jaffery, Hussain; Doran, David; Hezwani, Mohammad; Robbins, Phillip J; Yoshida, Mari; Cronin, Leroy

    2015-01-01

    Three dimensional (3D) printing is actively sought after in recent years as a promising novel technology to construct complex objects, which scope spans from nano- to over millimeter scale. Previously we utilized Fused deposition modeling (FDM)-based 3D printer to construct complex 3D chemical fluidic systems, and here we demonstrate the construction of 3D milli-fluidic structures for programmable liquid handling and control of biological samples. Basic fluidic operation devices, such as water-in-oil (W/O) droplet generators for producing compartmentalized mono-disperse droplets, sensor-integrated chamber for online monitoring of cellular growth, are presented. In addition, chemical surface treatment techniques are used to construct valve-based flow selector for liquid flow control and inter-connectable modular devices for networking fluidic parts. As such this work paves the way for complex operations, such as mixing, flow control, and monitoring of reaction / cell culture progress can be carried out by constructing both passive and active components in 3D printed structures, which designs can be shared online so that anyone with 3D printers can reproduce them by themselves.

  2. Device and methods for "gold standard" registration of clinical 3D and 2D cerebral angiograms

    NASA Astrophysics Data System (ADS)

    Madan, Hennadii; Likar, Boštjan; Pernuš, Franjo; Å piclin, Žiga

    2015-03-01

    Translation of any novel and existing 3D-2D image registration methods into clinical image-guidance systems is limited due to lack of their objective validation on clinical image datasets. The main reason is that, besides the calibration of the 2D imaging system, a reference or "gold standard" registration is very difficult to obtain on clinical image datasets. In the context of cerebral endovascular image-guided interventions (EIGIs), we present a calibration device in the form of a headband with integrated fiducial markers and, secondly, propose an automated pipeline comprising 3D and 2D image processing, analysis and annotation steps, the result of which is a retrospective calibration of the 2D imaging system and an optimal, i.e., "gold standard" registration of 3D and 2D images. The device and methods were used to create the "gold standard" on 15 datasets of 3D and 2D cerebral angiograms, whereas each dataset was acquired on a patient undergoing EIGI for either aneurysm coiling or embolization of arteriovenous malformation. The use of the device integrated seamlessly in the clinical workflow of EIGI. While the automated pipeline eliminated all manual input or interactive image processing, analysis or annotation. In this way, the time to obtain the "gold standard" was reduced from 30 to less than one minute and the "gold standard" of 3D-2D registration on all 15 datasets of cerebral angiograms was obtained with a sub-0.1 mm accuracy.

  3. Permanent 3D laser scanning system for an active landslide in Gresten (Austria)

    NASA Astrophysics Data System (ADS)

    Canli, Ekrem; Höfle, Bernhard; Hämmerle, Martin; Benni, Thiebes; Glade, Thomas

    2015-04-01

    Terrestrial laser scanners (TLS) have widely been used for high spatial resolution data acquisition of topographic features and geomorphic analyses. Existing applications encompass different landslides including rockfall, translational or rotational landslides, debris flow, but also coastal cliff erosion, braided river evolution or river bank erosion. The main advantages of TLS are (a) the high spatial sampling density of XYZ-measurements (e.g. 1 point every 2-3 mm at 10 m distance), particularly in comparison with the low data density monitoring techniques such as GNSS or total stations, (b) the millimeter accuracy and precision of the range measurement to centimeter accuracy of the final DEM, and (c) the highly dense area-wide scanning that enables to look through vegetation and to measure bare ground. One of its main constraints is the temporal resolution of acquired data due to labor costs and time requirements for field campaigns. Thus, repetition measurements are generally performed only episodically. However, for an increased scientific understanding of the processes as well as for early warning purposes, we present a novel permanent 3D monitoring setup to increase the temporal resolution of TLS measurements. This accounts for different potential monitoring deliverables such as volumetric calculations, spatio-temporal movement patterns, predictions and even alerting. This system was installed at the active Salcher landslide in Gresten (Austria) that is situated in the transition zone of the Gresten Klippenbelt (Helvetic) and the Flyschzone (Penninic). The characteristic lithofacies are the Gresten Beds of Early Jurassic age that are covered by a sequence of marly and silty beds with intercalated sandy limestones. Permanent data acquisition can be implemented into our workflow with any long-range TLS system offering fully automated capturing. We utilize an Optech ILRIS-3D scanner. The time interval between two scans is currently set to 24 hours, but can be

  4. 3D Printed Microfluidic Device with Integrated Biosensors for Online Analysis of Subcutaneous Human Microdialysate

    PubMed Central

    2015-01-01

    This work presents the design, fabrication, and characterization of a robust 3D printed microfluidic analysis system that integrates with FDA-approved clinical microdialysis probes for continuous monitoring of human tissue metabolite levels. The microfluidic device incorporates removable needle type integrated biosensors for glucose and lactate, which are optimized for high tissue concentrations, housed in novel 3D printed electrode holders. A soft compressible 3D printed elastomer at the base of the holder ensures a good seal with the microfluidic chip. Optimization of the channel size significantly improves the response time of the sensor. As a proof-of-concept study, our microfluidic device was coupled to lab-built wireless potentiostats and used to monitor real-time subcutaneous glucose and lactate levels in cyclists undergoing a training regime. PMID:26070023

  5. Some Experiences in 3D Laser Scanning for Assisting Restoration and Evaluating Damage in Cultural Heritage

    NASA Astrophysics Data System (ADS)

    Fuentes, L. M.; Finat, Javier; Fernández-Martin, J. J.; Martínez, J.; SanJose, J. I.

    The recent incorporation of laser devices provides advanced tools for assisting the conservation and restoration of Cultural Heritage. It is necessary to have as complete as possible understanding of the object state before evaluating or defining the reach of the restoration process. Thus, a special effort is devoted to surveying, measuring and generating a high-resolution 3D model prior to restoration planning. This work presents results of several experiments performed on damaged pieces for evaluation purposes in Cultural Heritage. Some software tools are applied for carving-work analysis, conservation-state monitoring, and simulation of weathering processes for evaluating temporal changes. In all cases considered, a high resolution information capture has been performed with a laser scanner, the Minolta 910. Our approach is flexible enough to be adapted to other kinds of pieces or Cultural Heritage artefacts, in order to provide an assessment for intervention planning in conservation and restoration tasks.

  6. Application of a hybrid 3D-2D laser scanning system to the characterization of slate slabs.

    PubMed

    López, Marcos; Martínez, Javier; Matías, José María; Vilán, José Antonio; Taboada, Javier

    2010-01-01

    Dimensional control based on 3D laser scanning techniques is widely used in practice. We describe the application of a hybrid 3D-2D laser scanning system to the characterization of slate slabs with structural defects that are difficult for the human eye to characterize objectively. Our study is based on automating the process using a 3D laser scanner and a 2D camera. Our results demonstrate that the application of this hybrid system optimally characterizes slate slabs in terms of the defects described by the Spanish UNE-EN 12326-1 standard.

  7. Numerical simulation of 3D boundary-driven acoustic streaming in microfluidic devices.

    PubMed

    Lei, Junjun; Hill, Martyn; Glynne-Jones, Peter

    2014-02-07

    This article discusses three-dimensional (3D) boundary-driven streaming in acoustofluidic devices. Firstly, the 3D Rayleigh streaming pattern in a microchannel is simulated and its effect on the movement of microparticles of various sizes is demonstrated. The results obtained from this model show good comparisons with 3D experimental visualisations and demonstrate the fully 3D nature of the acoustic streaming field and the associated acoustophoretic motion of microparticles in acoustofluidic devices. This method is then applied to another acoustofluidic device in order to gain insights into an unusual in-plane streaming pattern. The origin of this streaming has not been fully described and its characteristics cannot be explained from the classical theory of Rayleigh streaming. The simulated in-plane streaming pattern was in good agreement with the experimental visualisation. The mechanism behind it is shown to be related to the active sound intensity field, which supports our previous findings on the mechanism of the in-plane acoustic streaming pattern visualised and modelled in a thin-layered capillary device.

  8. 3D modelling of facade features on large sites acquired by vehicle based laser scanning

    NASA Astrophysics Data System (ADS)

    Boulaassal, H.; Landes, T.; Grussenmeyer, P.

    2011-12-01

    Mobile mapping laser scanning systems have become more and more widespread for the acquisition of millions of 3D points on large and geometrically complex urban sites. Vehicle-based Laser Scanning (VLS) systems travel many kilometers while acquiring raw point clouds which are registered in real time in a common coordinate system. Improvements of the acquisition steps as well as the automatic processing of the collected point clouds are still a conundrum for researchers. This paper shows some results obtained by application, on mobile laser scanner data, of segmentation and reconstruction algorithms intended initially to generate individual vector facade models using stationary Terrestrial Laser Scanner (TLS) data. The operating algorithms are adapted so as to take into account characteristics of VLS data. The intrinsic geometry of a point cloud as well as the relative geometry between registered point clouds are different from that obtained by a static TLS. The amount of data provided by this acquisition technique is another issue. Such particularities should be taken into consideration while processing this type of point clouds. The segmentation of VLS data is carried out based on an adaptation of RANSAC algorithm. Edge points of each element are extracted by applying a second algorithm. Afterwards, the vector models of each facade element are reconstructed. In order to validate the results, large samples with different characteristics have been introduced in the developed processing chain. The limitations as well as the capabilities of each process will be emphasized in terms of geometry and processing time.

  9. Automated analysis of barley organs using 3D laser scanning: an approach for high throughput phenotyping.

    PubMed

    Paulus, Stefan; Dupuis, Jan; Riedel, Sebastian; Kuhlmann, Heiner

    2014-07-15

    Due to the rise of laser scanning the 3D geometry of plant architecture is easy to acquire. Nevertheless, an automated interpretation and, finally, the segmentation into functional groups are still difficult to achieve. Two barley plants were scanned in a time course, and the organs were separated by applying a histogram-based classification algorithm. The leaf organs were represented by meshing algorithms, while the stem organs were parameterized by a least-squares cylinder approximation. We introduced surface feature histograms with an accuracy of 96% for the separation of the barley organs, leaf and stem. This enables growth monitoring in a time course for barley plants. Its reliability was demonstrated by a comparison with manually fitted parameters with a correlation R(2) = 0:99 for the leaf area and R(2) = 0:98 for the cumulated stem height. A proof of concept has been given for its applicability for the detection of water stress in barley, where the extension growth of an irrigated and a non-irrigated plant has been monitored.

  10. Stress-induced Effects Caused by 3D IC TSV Packaging in Advanced Semiconductor Device Performance

    NASA Astrophysics Data System (ADS)

    Sukharev, V.; Kteyan, A.; Choy, J.-H.; Hovsepyan, H.; Markosian, A.; Zschech, E.; Huebner, R.

    2011-11-01

    Potential challenges with managing mechanical stress and the consequent effects on device performance for advanced 3D through-silicon-via (TSV) based technologies are outlined. The paper addresses the growing need in a simulation-based design verification flow capable to analyze a design of 3D IC stacks and to determine across-die out-of-spec variations in device electrical characteristics caused by the layout and through-silicon-via (TSV)/package-induced mechanical stress. The limited characterization/measurement capabilities for 3D IC stacks and a strict "good die" requirement make this type of analysis critical for the achievement of an acceptable level of functional and parametric yield and reliability. The paper focuses on the development of a design-for-manufacturability (DFM) type of methodology for managing mechanical stresses during a sequence of designs of 3D TSV-based dies, stacks and packages. A set of physics-based compact models for a multi-scale simulation to assess the mechanical stress across the device layers in silicon chips stacked and packaged with the 3D TSV technology is proposed. A calibration technique based on fitting to measured stress components and electrical characteristics of the test-chip devices is presented. A strategy for generation of a simulation feeding data and respective materials characterization approach are proposed, with the goal to generate a database for multi-scale material parameters of wafer-level and package-level structures. For model validation, high-resolution strain measurements in Si channels of the test-chip devices are needed. At the nanoscale, the transmission electron microscopy (TEM) is the only technique available for sub-10 nm strain measurements so far.

  11. Vertical Scan (V-SCAN) for 3-D Grid Adaptive Mesh Refinement for an atmospheric Model Dynamical Core

    NASA Astrophysics Data System (ADS)

    Andronova, N. G.; Vandenberg, D.; Oehmke, R.; Stout, Q. F.; Penner, J. E.

    2009-12-01

    One of the major building blocks of a rigorous representation of cloud evolution in global atmospheric models is a parallel adaptive grid MPI-based communication library (an Adaptive Blocks for Locally Cartesian Topologies library -- ABLCarT), which manages the block-structured data layout, handles ghost cell updates among neighboring blocks and splits a block as refinements occur. The library has several modules that provide a layer of abstraction for adaptive refinement: blocks, which contain individual cells of user data; shells - the global geometry for the problem, including a sphere, reduced sphere, and now a 3D sphere; a load balancer for placement of blocks onto processors; and a communication support layer which encapsulates all data movement. A major performance concern with adaptive mesh refinement is how to represent calculations that have need to be sequenced in a particular order in a direction, such as calculating integrals along a specific path (e.g. atmospheric pressure or geopotential in the vertical dimension). This concern is compounded if the blocks have varying levels of refinement, or are scattered across different processors, as can be the case in parallel computing. In this paper we describe an implementation in ABLCarT of a vertical scan operation, which allows computing along vertical paths in the correct order across blocks transparent to their resolution and processor location. We test this functionality on a 2D and a 3D advection problem, which tests the performance of the model’s dynamics (transport) and physics (sources and sinks) for different model resolutions needed for inclusion of cloud formation.

  12. 3D-FBK Pixel Sensors: Recent Beam Tests Results with Irradiated Devices

    SciTech Connect

    Micelli, A.; Helle, K.; Sandaker, H.; Stugu, B.; Barbero, M.; Hugging, F.; Karagounis, M.; Kostyukhin, V.; Kruger, H.; Tsung, J.W.; Wermes, N.; Capua, M.; Fazio, S.; Mastroberardino, A.; Susinno, G.; Gallrapp, C.; Di Girolamo, B.; Dobos, D.; La Rosa, A.; Pernegger, H.; Roe, S.; /CERN /Prague, Tech. U. /Prague, Tech. U. /Freiburg U. /Freiburg U. /Freiburg U. /INFN, Genoa /Genoa U. /INFN, Genoa /Genoa U. /INFN, Genoa /Genoa U. /INFN, Genoa /Genoa U. /INFN, Genoa /Genoa U. /Glasgow U. /Glasgow U. /Glasgow U. /Hawaii U. /Barcelona, IFAE /Barcelona, IFAE /LBL, Berkeley /Barcelona, IFAE /LBL, Berkeley /LBL, Berkeley /Manchester U. /Manchester U. /Manchester U. /Manchester U. /Manchester U. /Manchester U. /Manchester U. /Manchester U. /Manchester U. /New Mexico U. /New Mexico U. /Oslo U. /Oslo U. /Oslo U. /Oslo U. /Oslo U. /SLAC /SLAC /SLAC /SLAC /SLAC /SLAC /SLAC /SLAC /SLAC /SUNY, Stony Brook /SUNY, Stony Brook /SUNY, Stony Brook /INFN, Trento /Trento U. /INFN, Trento /Trento U. /INFN, Trento /Trento U. /INFN, Trieste /Udine U. /INFN, Trieste /Udine U. /INFN, Trieste /Udine U. /INFN, Trieste /Udine U. /INFN, Trieste /Udine U. /INFN, Trieste /Udine U. /Barcelona, Inst. Microelectron. /Barcelona, Inst. Microelectron. /Barcelona, Inst. Microelectron. /Fond. Bruno Kessler, Trento /Fond. Bruno Kessler, Trento /Fond. Bruno Kessler, Trento /Fond. Bruno Kessler, Trento /Fond. Bruno Kessler, Trento /SINTEF, Oslo /SINTEF, Oslo /SINTEF, Oslo /SINTEF, Oslo /VTT Electronics, Espoo /VTT Electronics, Espoo

    2012-04-30

    The Pixel Detector is the innermost part of the ATLAS experiment tracking device at the Large Hadron Collider, and plays a key role in the reconstruction of the primary vertices from the collisions and secondary vertices produced by short-lived particles. To cope with the high level of radiation produced during the collider operation, it is planned to add to the present three layers of silicon pixel sensors which constitute the Pixel Detector, an additional layer (Insertable B-Layer, or IBL) of sensors. 3D silicon sensors are one of the technologies which are under study for the IBL. 3D silicon technology is an innovative combination of very-large-scale integration and Micro-Electro-Mechanical-Systems where electrodes are fabricated inside the silicon bulk instead of being implanted on the wafer surfaces. 3D sensors, with electrodes fully or partially penetrating the silicon substrate, are currently fabricated at different processing facilities in Europe and USA. This paper reports on the 2010 June beam test results for irradiated 3D devices produced at FBK (Trento, Italy). The performance of these devices, all bump-bonded with the ATLAS pixel FE-I3 read-out chip, is compared to that observed before irradiation in a previous beam test.

  13. Scalable Iterative Solvers Applied to 3D Parallel Simulation of Advanced Semiconductor Devices

    NASA Astrophysics Data System (ADS)

    García-Loureiro, A. J.; Aldegunde, M.; Seoane, N.

    2009-08-01

    We have studied the performance of a preconditioned iterative solver to speed up a 3D semiconductor device simulator. Since 3D simulations necessitate large computing resources, the choice of algorithms and their parameters become of utmost importance. This code uses a density gradient drift-diffusion semiconductor transport model based on the finite element method which is one of the most general and complex discretisation techniques. It has been implemented for a distributed memory multiprocessor environment using the Message Passing Interface (MPI) library. We have applied this simulator to a 67 nm effective gate length Si MOSFET.

  14. A primary study of appropriate intraoral scanning frequency of single 3D image

    NASA Astrophysics Data System (ADS)

    Li, Hong; Lyu, Peijun; Sun, Yuchun; Wang, Yong; Liang, Xiaoyue

    2015-07-01

    Objective To make a quantitative analysis between sampling frequencies and micro-movement distance of mark points on tooth surfaces, and to provide a reference for sampling frequency settings of intraoral scanning systems. Methods Mark points affixed to the incisors of five subjects. In total, 3600 groups of tracking point coordinates were obtained with frequencies of 60, 150 and 300 Hz using an optical 3D tracking system. The data was then re-sampled to obtain coordinates at lower frequencies (5, 10, 15 and 20 Hz) at equal intervals of groups of tracking point coordinates. Change in distance (Δd) was defined as the change in position of a single v from one sampling time point to another, and was valued by clinical accuracy requirement (20-100μm). The curve equation was fit quantitatively between Δd median (M) and the sampling frequency (f). The difference between upper and lower incisor mark points were analyzed by a non-parametric test; α=0.05. Result When the frequency (f) was 60 Hz, upper jaw Δd median (M) and interquartile (Q) were 14.4 μm and 9.2 μm, respectively, while the lower Δd(M) and (Q) were 6.4 μm and 10.2 μm, respectively. Every Δd value was less than 100 μm, while 74% of Δd vales were less than 20 μm. Δd(M) and f satisfy the power curve equation: Δd(M)=0.526×f-0.979(f∈[5,300]). Significant differences of incisor feature points were noted between upper and lower jaws of the same subject (P<0.01). Conclusion Clinical accuracy can be met when the sampling frequency of the intraoral scanning system is 60 Hz.

  15. Matching 3-D prone and supine CT colonography scans using graphs.

    PubMed

    Wang, Shijun; Petrick, Nicholas; Van Uitert, Robert L; Periaswamy, Senthil; Wei, Zhuoshi; Summers, Ronald M

    2012-07-01

    In this paper, we propose a new registration method for prone and supine computed tomographic colonography scans using graph matching. We formulate 3-D colon registration as a graph matching problem and propose a new graph matching algorithm based on mean field theory. In the proposed algorithm, we solve the matching problem in an iterative way. In each step, we use mean field theory to find the matched pair of nodes with highest probability. During iterative optimization, one-to-one matching constraints are added to the system in a step-by-step approach. Prominent matching pairs found in previous iterations are used to guide subsequent mean field calculations. The proposed method was found to have the best performance with smallest standard deviation compared with two other baseline algorithms called the normalized distance along the colon centerline (NDACC) ( p = 0.17) with manual colon centerline correction and spectral matching ( p < 1e-5). A major advantage of the proposed method is that it is fully automatic and does not require defining a colon centerline for registration. For the latter NDACC method, user interaction is almost always needed for identifying the colon centerlines.

  16. 3D image reconstruction using optical sectioning in confocal scanning microscopy

    NASA Astrophysics Data System (ADS)

    Seo, Jungwoo; Kang, Dong Kyun; Park, Sunglim; Gweon, Dae gab

    2001-10-01

    Confocal scanning microscopy (CSM) has been used in biological application, materials science, semiconductor quality measurement and other non-destructive microscopic application. Small spot of light illuminates a sample, and a small detector that is ideally a point detector collects the reflected or transmitted light having the information of specimen. An image distribution can be reconstructed by a correlation analysis of spots with the high bandwidth. The mechanism for two-dimensional beam scanning and optical sectioning has an important role in CSM as the three-dimensional profiler. The parasitic motion of focus on the detector gives rise to the fatal distortion of an image profile named the extinction effect while using acousto-optical (AO) deflector. The intensity profile for the open loop scanning should be matched with its response for the standard. The non-linearity can be minimized with the optical sectioning or the optical probe of the closed loop control. This paper shows the mathematical expression of the light such as the extinction curve in the optical fields of system using AO deflector, the axial/lateral response experimentally when the error sources change, and the methods of optical sectioning. We propose the progressive methods for the high quality image as the following. At first, for having the corrected image, small spot and long scan range, this paper shows that the optimal design having the multi-objects can be used by choosing the unitary lens device in CSM. At second, in order to compensate for the intensity cancellation at the end profile that may be the cause of waviness for the optical image, this paper shows that it is efficient to schedule the frequency of scan. According to characteristics of the extinction curve and axial/lateral response having the error property, we can define the frequency and sensitivity of as their robustness. Finally, the axial response gives an important motive for the optical section, and the limit of

  17. Arbitrarily Accessible 3D Microfluidic Device for Combinatorial High-Throughput Drug Screening

    PubMed Central

    Chen, Zhuofa; Li, Weizhi; Choi, Gihoon; Yang, Xiaonan; Miao, Jun; Cui, Liwang; Guan, Weihua

    2016-01-01

    Microfluidics-based drug-screening systems have enabled efficient and high-throughput drug screening, but their routine uses in ordinary labs are limited due to the complexity involved in device fabrication and system setup. In this work, we report an easy-to-use and low-cost arbitrarily accessible 3D microfluidic device that can be easily adopted by various labs to perform combinatorial assays for high-throughput drug screening. The device is capable of precisely performing automatic and simultaneous reagent loading and aliquoting tasks and performing multistep assays with arbitrary sequences. The device is not intended to compete with other microfluidic technologies regarding ultra-low reaction volume. Instead, its freedom from tubing or pumping systems and easy operation makes it an ideal platform for routine high-throughput drug screening outside traditional microfluidic labs. The functionality and quantitative reliability of the 3D microfluidic device were demonstrated with a histone acetyltransferase-based drug-screening assay using the recombinant Plasmodium falciparum GCN5 enzyme, benchmarked with a traditional microtiter plate-based method. This arbitrarily accessible, multistep capable, low-cost, and easy-to-use device can be widely adopted in various combinatorial assays beyond high-throughput drug screening. PMID:27690055

  18. Developing a protocol for creating microfluidic devices with a 3D printer, PDMS, and glass

    NASA Astrophysics Data System (ADS)

    Collette, Robyn; Novak, Eric; Shirk, Kathryn

    2015-03-01

    Microfluidics research requires the design and fabrication of devices that have the ability to manipulate small volumes of fluid, typically ranging from microliters to picoliters. These devices are used for a wide range of applications including the assembly of materials and testing of biological samples. Many methods have been previously developed to create microfluidic devices, including traditional nanolithography techniques. However, these traditional techniques are cost-prohibitive for many small-scale laboratories. This research explores a relatively low-cost technique using a 3D printed master, which is used as a template for the fabrication of polydimethylsiloxane (PDMS) microfluidic devices. The masters are designed using computer aided design (CAD) software and can be printed and modified relatively quickly. We have developed a protocol for creating simple microfluidic devices using a 3D printer and PDMS adhered to glass. This relatively simple and lower-cost technique can now be scaled to more complicated device designs and applications. Funding provided by the Undergraduate Research Grant Program at Shippensburg University and the Student/Faculty Research Engagement Grants from the College of Arts and Sciences at Shippensburg University.

  19. The effect of pose variability and repeated reliability of segmental centres of mass acquisition when using 3D photonic scanning.

    PubMed

    Chiu, Chuang-Yuan; Pease, David L; Sanders, Ross H

    2016-12-01

    Three-dimensional (3D) photonic scanning is an emerging technique to acquire accurate body segment parameter data. This study established the repeated reliability of segmental centres of mass when using 3D photonic scanning (3DPS). Seventeen male participants were scanned twice by a 3D whole-body laser scanner. The same operators conducted the reconstruction and segmentation processes to obtain segmental meshes for calculating the segmental centres of mass. The segmental centres of mass obtained from repeated 3DPS were compared by relative technical error of measurement (TEM). Hypothesis tests were conducted to determine the size of change required for each segment to be determined a true variation. The relative TEMs for all segments were less than 5%. The relative changes in centres of mass at ±1.5% for most segments can be detected (p < 0.05). The arm segments which are difficult to keep in the same scanning pose generated more error than other segments. Practitioner Summary: Three-dimensional photonic scanning is an emerging technique to acquire body segment parameter data. This study established the repeated reliability of segmental centres of mass when using 3D photonic scanning and emphasised that the error for arm segments need to be considered while using this technique to acquire centres of mass.

  20. Axial-Stereo 3-D Optical Metrology for Inner Profile of Pipes Using a Scanning Laser Endoscope.

    PubMed

    Gong, Yuanzheng; Johnston, Richard S; Melville, C David; Seibel, Eric J

    As the rapid progress in the development of optoelectronic components and computational power, 3D optical metrology becomes more and more popular in manufacturing and quality control due to its flexibility and high speed. However, most of the optical metrology methods are limited to external surfaces. This paper proposed a new approach to measure tiny internal 3D surfaces with a scanning fiber endoscope and axial-stereo vision algorithm. A dense, accurate point cloud of internally machined threads was generated to compare with its corresponding X-ray 3D data as ground truth, and the quantification was analyzed by Iterative Closest Points algorithm.

  1. Axial-Stereo 3-D Optical Metrology for Inner Profile of Pipes Using a Scanning Laser Endoscope

    PubMed Central

    Gong, Yuanzheng; Johnston, Richard S.; Melville, C. David; Seibel, Eric J.

    2015-01-01

    As the rapid progress in the development of optoelectronic components and computational power, 3D optical metrology becomes more and more popular in manufacturing and quality control due to its flexibility and high speed. However, most of the optical metrology methods are limited to external surfaces. This paper proposed a new approach to measure tiny internal 3D surfaces with a scanning fiber endoscope and axial-stereo vision algorithm. A dense, accurate point cloud of internally machined threads was generated to compare with its corresponding X-ray 3D data as ground truth, and the quantification was analyzed by Iterative Closest Points algorithm. PMID:26640425

  2. Low-Cost 3D Laser Scanning in Air or Water Using Self-Calibrating Structured Light

    NASA Astrophysics Data System (ADS)

    Bleier, M.; Nüchter, A.

    2017-02-01

    In-situ calibration of structured light scanners in underwater environments is time-consuming and complicated. This paper presents a self-calibrating line laser scanning system, which enables the creation of dense 3D models with a single fixed camera and a freely moving hand-held cross line laser projector. The proposed approach exploits geometric constraints, such as coplanarities, to recover the depth information and is applicable without any prior knowledge of the position and orientation of the laser projector. By employing an off-the-shelf underwater camera and a waterproof housing with high power line lasers an affordable 3D scanning solution can be built. In experiments the performance of the proposed technique is studied and compared with 3D reconstruction using explicit calibration. We demonstrate that the scanning system can be applied to above-the-water as well as underwater scenes.

  3. Analysis of Uncertainty in a Middle-Cost Device for 3D Measurements in BIM Perspective

    PubMed Central

    Sánchez, Alonso; Naranjo, José-Manuel; Jiménez, Antonio; González, Alfonso

    2016-01-01

    Medium-cost devices equipped with sensors are being developed to get 3D measurements. Some allow for generating geometric models and point clouds. Nevertheless, the accuracy of these measurements should be evaluated, taking into account the requirements of the Building Information Model (BIM). This paper analyzes the uncertainty in outdoor/indoor three-dimensional coordinate measures and point clouds (using Spherical Accuracy Standard (SAS) methods) for Eyes Map, a medium-cost tablet manufactured by e-Capture Research & Development Company, Mérida, Spain. To achieve it, in outdoor tests, by means of this device, the coordinates of targets were measured from 1 to 6 m and cloud points were obtained. Subsequently, these were compared to the coordinates of the same targets measured by a Total Station. The Euclidean average distance error was 0.005–0.027 m for measurements by Photogrammetry and 0.013–0.021 m for the point clouds. All of them satisfy the tolerance for point cloud acquisition (0.051 m) according to the BIM Guide for 3D Imaging (General Services Administration); similar results are obtained in the indoor tests, with values of 0.022 m. In this paper, we establish the optimal distances for the observations in both, Photogrammetry and 3D Photomodeling modes (outdoor) and point out some working conditions to avoid in indoor environments. Finally, the authors discuss some recommendations for improving the performance and working methods of the device. PMID:27669245

  4. Analysis of Uncertainty in a Middle-Cost Device for 3D Measurements in BIM Perspective.

    PubMed

    Sánchez, Alonso; Naranjo, José-Manuel; Jiménez, Antonio; González, Alfonso

    2016-09-22

    Medium-cost devices equipped with sensors are being developed to get 3D measurements. Some allow for generating geometric models and point clouds. Nevertheless, the accuracy of these measurements should be evaluated, taking into account the requirements of the Building Information Model (BIM). This paper analyzes the uncertainty in outdoor/indoor three-dimensional coordinate measures and point clouds (using Spherical Accuracy Standard (SAS) methods) for Eyes Map, a medium-cost tablet manufactured by e-Capture Research & Development Company, Mérida, Spain. To achieve it, in outdoor tests, by means of this device, the coordinates of targets were measured from 1 to 6 m and cloud points were obtained. Subsequently, these were compared to the coordinates of the same targets measured by a Total Station. The Euclidean average distance error was 0.005-0.027 m for measurements by Photogrammetry and 0.013-0.021 m for the point clouds. All of them satisfy the tolerance for point cloud acquisition (0.051 m) according to the BIM Guide for 3D Imaging (General Services Administration); similar results are obtained in the indoor tests, with values of 0.022 m. In this paper, we establish the optimal distances for the observations in both, Photogrammetry and 3D Photomodeling modes (outdoor) and point out some working conditions to avoid in indoor environments. Finally, the authors discuss some recommendations for improving the performance and working methods of the device.

  5. 3-D LTCC microfluidic device as a tool for studying nanoprecipitation

    NASA Astrophysics Data System (ADS)

    Schianti, J. N.; Cerize, N. P. N.; Oliveira, A. M.; Derenzo, S.; Góngora-Rubio, M. R.

    2013-03-01

    Nanoparticles have been used to improve the properties of many cosmetic products, mainly the sunscreens materials using nanoencapsulation or nanosuspensions, improving the contact with active molecules, enhancing the sun protection effect and facilitating formulations in industrial products. Microfluidic devices offer an important possibility in producing nanoparticles in a simple way, in one step bottom up technique, continuum process with low polidispersivity, low consumption of reagents and additives. In this work, we microfabricated a 3-D LTCC microfluidic device to study the nanoprecipitation of Benzophenone-3, used as a sunscreen in pharmaceutical products. It was observed that some parameters influence the particle size related to the total fluid flow on device, the ratio between phases, and the Benzophenone-3 initial concentration. The influence of applied voltages on particle sizes was tested also. For the processing, a high voltage was applied in a Kovar tube inserted in the 3D device. The use of microfluidic device resulted in particles with 100 up to 800 nm of size, with polispersivity index below 0.3 and offering an interesting way to obtain nanoparticles. These studies are still ongoing, but early results indicate the possibility of obtaining B-3 nanostructured material.

  6. Make or Buy: Cost Impacts of Additive Manufacturing, 3D Laser Scanning Technology, and Collaborative Product Lifecycle Management on Ship Maintenance and Modernization

    DTIC Science & Technology

    2015-05-01

    1 Make or Buy: Cost Impacts of Additive Manufacturing , 3D Laser Scanning Technology, and Collaborative Product Lifecycle Management on Ship...DATES COVERED 00-00-2015 to 00-00-2015 4. TITLE AND SUBTITLE Make or Buy: Cost Impacts of Additive Manufacturing , 3D Laser Scanning Technology...management during operations 4 Potential Technology 3: Additive Manufacturing (“3D Printing”) 5 • 3D design/image (e.g. from 3D LS) of final part

  7. Respiratory gating for proton beam scanning versus photon 3D-CRT for breast cancer radiotherapy.

    PubMed

    Flejmer, Anna M; Edvardsson, Anneli; Dohlmar, Frida; Josefsson, Dan; Nilsson, Mats; Witt Nyström, Petra; Dasu, Alexandru

    2016-05-01

    Background Respiratory gating and proton therapy have both been proposed to reduce the cardiopulmonary burden in breast cancer radiotherapy. This study aims to investigate the additional benefit of proton radiotherapy for breast cancer with and without respiratory gating. Material and methods Twenty left-sided patients were planned on computed tomography (CT)-datasets acquired during enhanced inspiration gating (EIG) and free-breathing (FB), using photon three-dimensional conformal radiation therapy (3D-CRT) and scanned proton beams. Ten patients received treatment to the whole breast only (WBO) and 10 were treated to the breast and the regional lymph nodes (BRN). Dosimetric parameters characterizing the coverage of target volumes and the cardiopulmonary burden were compared using a paired, two-tailed Student's t-test. Results Protons ensured comparable or better target coverage than photons in all patients during both EIG and FB. The heterogeneity index decreased from 12% with photons to about 5% with protons. The mean dose to the ipsilateral lung was reduced in BRN patients from 12 Gy to 7 Gy  (RBE) in EIG and from 14 Gy to 6-7 Gy (RBE) in FB, while for WBO patients all values were about 5-6 Gy (RBE). The mean dose to heart decreased by a factor of four in WBO patients [from 1.1 Gy to 0.3 Gy (RBE) in EIG and from 2.1 Gy to 0.5 Gy (RBE) in FB] and 10 in BRN patients [from 2.1 Gy to 0.2 Gy (RBE) in EIG and from 3.4 Gy to 0.3 Gy (RBE) in FB]. Similarly, the mean and the near maximum dose to the left anterior descending artery (LAD) were significantly lower (p < 0.05) with protons in comparison with photons. Conclusion Proton spot scanning has a high potential to reduce the irradiation of organs at risk and other normal tissues for most patients, beyond what could be achieved with EIG and photon therapy. The largest dose sparing has been seen for BRN patients, both in terms of cardiopulmonary burden and integral dose.

  8. Testing a Novel 3D Printed Radiographic Imaging Device for Use in Forensic Odontology.

    PubMed

    Newcomb, Tara L; Bruhn, Ann M; Giles, Bridget; Garcia, Hector M; Diawara, Norou

    2017-01-01

    There are specific challenges related to forensic dental radiology and difficulties in aligning X-ray equipment to teeth of interest. Researchers used 3D printing to create a new device, the combined holding and aiming device (CHAD), to address the positioning limitations of current dental X-ray devices. Participants (N = 24) used the CHAD, soft dental wax, and a modified external aiming device (MEAD) to determine device preference, radiographer's efficiency, and technique errors. Each participant exposed six X-rays per device for a total of 432 X-rays scored. A significant difference was found at the 0.05 level between the three devices (p = 0.0015), with the MEAD having the least amount of total errors and soft dental wax taking the least amount of time. Total errors were highest when participants used soft dental wax-both the MEAD and the CHAD performed best overall. Further research in forensic dental radiology and use of holding devices is needed.

  9. Kilo-scale droplet generation in three-dimensional monolithic elastomer device (3D MED).

    PubMed

    Jeong, Heon-Ho; Yelleswarapu, Venkata R; Yadavali, Sagar; Issadore, David; Lee, Daeyeon

    2015-12-07

    Droplet-based microfluidics has led to transformational new approaches in diverse areas including materials synthesis and high-throughput biological assays. However, the translation of droplet microfluidics technology into commercial applications requires scale-up of droplet generation from the laboratory (<10 mL h(-1)) to the industrial (>1 L h(-1)) scale. To address this challenge, we develop a three-dimensional monolithic elastomer device (3D MED) for mass production of monodisperse emulsion droplets. Using double-sided imprinting, 3D microchannels are formed in a single elastomer piece that has 1000 parallel flow focusing generators (k-FFGs). Compared to previous work that parallelizes droplet generation, the 3D MED eliminates the needs for alignment and bonding of multiple pieces and thus makes it possible to achieve the high flow rates and pressure necessary for the kilo-scale generation of droplets. Using this approach, we demonstrate mass production of water-in-oil (W/O) emulsion droplets at production rates as high as 1.5 L h(-1) (>30 billion 45 μm diameter droplets per hour), with a coefficient of variation of droplet diameter of only 6.6%. Because of the simplicity, robustness, and manufacturability of our 3D MED architecture, it is well suited to bridge the gap between the continuously growing library of promising microfluidic technologies to generate microparticles that have been demonstrated in laboratory settings and their successful application in industry.

  10. High-resolution 3-D mapping using terrestrial laser scanning as a tool for geomorphological and speleogenetical studies in caves: An example from the Lessini mountains (North Italy)

    NASA Astrophysics Data System (ADS)

    Fabbri, Stefano; Sauro, Francesco; Santagata, Tommaso; Rossi, Guido; De Waele, Jo

    2017-03-01

    Terrestrial laser scanning (TLS) is increasingly used in geomorphology for the study of medium- to small scale landforms. A light weight, compact and portable TLS device has been used in the Grotta A Cave (Mt. Lessini, N Italy) to make a detailed 3D model of the underground environment. A total of 16 scans were used to survey the about 150 m long cave in < 6 h. The 3D model of the cave walls makes it possible to carry out morphometric measurements on the different cave environments. The TLS data allowed us to calculate cave volumes and distinguish cupola, phreatic conduit and basalt dike volumes. Wall roughness analysis also allowed recognising smaller-scale morphologies such as megascallops, differential corrosion forms and mineral crusts. These observations have enabled us to discern between different karstification processes and speleogenetic phases, highlighting the importance of condensation-corrosion on the cave passage enlargement in a quantitative way.

  11. Web-based 3D digital pathology framework for large-mapping data scanned by FF-OCT

    NASA Astrophysics Data System (ADS)

    Chang, ChiaKai; Tsai, Chien-Chung; Chien, Meng-Ting; Li, Yu-I.; Shun, Chia-Tung; Huang, Sheng-Lung

    2015-03-01

    Full-Field Optical Coherence Tomography (FF-OCT) is a high resolution instrument in 3 dimensional (3D) space, including lateral and longitudinal direction. With FF-OCT, we can perform 3D scanning for excised biopsy or cell culture sample to obtain cellular information. In this work, we have set up a high resolution FF-OCT scanning instrument that can perform cellular resolution tomography scanning of skin tissue for histopathology study. In a scan range of 1cm(x), 1cm(y), 106μm(z), for example, digital data occupies 253 GB capacity. Copying these materials is time consuming, not to mention efficient browsing and analyzing of these data. To solve the problem of information delivery, we have established a network service to browse and analyze the huge volume data.

  12. Interpretation and mapping of geological features using mobile devices for 3D outcrop modelling

    NASA Astrophysics Data System (ADS)

    Buckley, Simon J.; Kehl, Christian; Mullins, James R.; Howell, John A.

    2016-04-01

    Advances in 3D digital geometric characterisation have resulted in widespread adoption in recent years, with photorealistic models utilised for interpretation, quantitative and qualitative analysis, as well as education, in an increasingly diverse range of geoscience applications. Topographic models created using lidar and photogrammetry, optionally combined with imagery from sensors such as hyperspectral and thermal cameras, are now becoming commonplace in geoscientific research. Mobile devices (tablets and smartphones) are maturing rapidly to become powerful field computers capable of displaying and interpreting 3D models directly in the field. With increasingly high-quality digital image capture, combined with on-board sensor pose estimation, mobile devices are, in addition, a source of primary data, which can be employed to enhance existing geological models. Adding supplementary image textures and 2D annotations to photorealistic models is therefore a desirable next step to complement conventional field geoscience. This contribution reports on research into field-based interpretation and conceptual sketching on images and photorealistic models on mobile devices, motivated by the desire to utilise digital outcrop models to generate high quality training images (TIs) for multipoint statistics (MPS) property modelling. Representative training images define sedimentological concepts and spatial relationships between elements in the system, which are subsequently modelled using artificial learning to populate geocellular models. Photorealistic outcrop models are underused sources of quantitative and qualitative information for generating TIs, explored further in this research by linking field and office workflows through the mobile device. Existing textured models are loaded to the mobile device, allowing rendering in a 3D environment. Because interpretation in 2D is more familiar and comfortable for users, the developed application allows new images to be captured

  13. The ultrasound brain helmet: early human feasibility study of multiple simultaneous 3D scans of cerebral vasculature

    NASA Astrophysics Data System (ADS)

    Lindsey, Brooks D.; Ivancevich, Nikolas M.; Whitman, John; Light, Edward; Fronheiser, Matthew; Nicoletto, Heather A.; Laskowitz, Daniel T.; Smith, Stephen W.

    2009-02-01

    We describe early stage experiments to test the feasibility of an ultrasound brain helmet to produce multiple simultaneous real-time 3D scans of the cerebral vasculature from temporal and suboccipital acoustic windows of the skull. The transducer hardware and software of the Volumetrics Medical Imaging real-time 3D scanner were modified to support dual 2.5 MHz matrix arrays of 256 transmit elements and 128 receive elements which produce two simultaneous 64° pyramidal scans. The real-time display format consists of two coronal B-mode images merged into a 128° sector, two simultaneous parasagittal images merged into a 128° × 64° C-mode plane, and a simultaneous 64° axial image. Real-time 3D color Doppler images acquired in initial clinical studies after contrast injection demonstrate flow in several representative blood vessels. An offline Doppler rendering of data from two transducers simultaneously scanning via the temporal windows provides an early visualization of the flow in vessels on both sides of the brain. The long-term goal is to produce real-time 3D ultrasound images of the cerebral vasculature from a portable unit capable of internet transmission, thus enabling interactive 3D imaging, remote diagnosis and earlier therapeutic intervention. We are motivated by the urgency for rapid diagnosis of stroke due to the short time window of effective therapeutic intervention.

  14. Electrochemiluminescence at Bare and DNA-Coated Graphite Electrodes in 3D-Printed Fluidic Devices.

    PubMed

    Bishop, Gregory W; Satterwhite-Warden, Jennifer E; Bist, Itti; Chen, Eric; Rusling, James F

    Clear plastic fluidic devices with ports for incorporating electrodes to enable electrochemiluminescence (ECL) measurements were prepared using a low-cost, desktop three-dimensional (3D) printer based on stereolithography. Electrodes consisted of 0.5 mm pencil graphite rods and 0.5 mm silver wires inserted into commercially available 1/4 in.-28 threaded fittings. A bioimaging system equipped with a CCD camera was used to measure ECL generated at electrodes and small arrays using 0.2 M phosphate buffer solutions containing tris(2,2'-bipyridyl)dichlororuthenium(II) hexahydrate ([Ru(bpy)3](2+)) with 100 mM tri-n-propylamine (TPA) as the coreactant. ECL signals produced at pencil graphite working electrodes were linear with respect to [Ru(bpy)3](2+) concentration for 9-900 μM [Ru(bpy)3](2+). The detection limit was found to be 7 μM using the CCD camera with exposure time set at 10 s. Electrode-to-electrode ECL signals varied by ±7.5%. Device performance was further evaluated using pencil graphite electrodes coated with multilayer poly(diallyldimethylammonium chloride) (PDDA)/DNA films. In these experiments, ECL resulted from the reaction of [Ru(bpy)3](3+) with guanines of DNA. ECL produced at these thin-film electrodes was linear with respect to [Ru(bpy)3](2+) concentration from 180 to 800 μM. These studies provide the first demonstration of ECL measurements obtained using a 3D-printed closed-channel fluidic device platform. The affordable, high-resolution 3D printer used in these studies enables easy, fast, and adaptable prototyping of fluidic devices capable of incorporating electrodes for measuring ECL.

  15. "High-precision, reconstructed 3D model" of skull scanned by conebeam CT: Reproducibility verified using CAD/CAM data.

    PubMed

    Katsumura, Seiko; Sato, Keita; Ikawa, Tomoko; Yamamura, Keiko; Ando, Eriko; Shigeta, Yuko; Ogawa, Takumi

    2016-01-01

    Computed tomography (CT) scanning has recently been introduced into forensic medicine and dentistry. However, the presence of metal restorations in the dentition can adversely affect the quality of three-dimensional reconstruction from CT scans. In this study, we aimed to evaluate the reproducibility of a "high-precision, reconstructed 3D model" obtained from a conebeam CT scan of dentition, a method that might be particularly helpful in forensic medicine. We took conebeam CT and helical CT images of three dry skulls marked with 47 measuring points; reconstructed three-dimensional images; and measured the distances between the points in the 3D images with a computer-aided design/computer-aided manufacturing (CAD/CAM) marker. We found that in comparison with the helical CT, conebeam CT is capable of reproducing measurements closer to those obtained from the actual samples. In conclusion, our study indicated that the image-reproduction from a conebeam CT scan was more accurate than that from a helical CT scan. Furthermore, the "high-precision reconstructed 3D model" facilitates reliable visualization of full-sized oral and maxillofacial regions in both helical and conebeam CT scans.

  16. Optical absorption enhancement in 3D nanofibers coated on polymer substrate for photovoltaic devices.

    PubMed

    Kiani, Amirkianoosh; Venkatakrishnan, Krishnan; Tan, Bo

    2015-06-01

    Recent research in the field of photovoltaics has shown that polymer solar cells have great potential to provide low-cost, lightweight and flexible electronic devices to harvest solar energy. In this paper, we propose a new method for the generation of three-dimensional nanofibers coated on polymer substrate induced by femtosecond laser pulses. In this new method, a thin layer of polymer is irradiated by megahertz femtosecond laser pulses under ambient conditions, and a thin fibrous layer is generated on top of the polymer substrate. This method is single step; no additional materials are added, and the layers of the three-dimensional (3D) polymer nanofibrous structures are grown on top of the substrate after laser irradiation. Light spectroscopy results show significant enhancement of light absorption in the generated 3D nanofibrous layers of polymer. Finally, we suggest how to maximize the light trapping and optical absorption of the generated nanofiber cells by optimizing the laser parameters.

  17. A porous 3D cell culture micro device for cell migration study.

    PubMed

    Ma, Liang; Zhou, Changchun; Lin, Biaoyang; Li, Wei

    2010-08-01

    Cell migration under chemoattractant is an important biological step in cancer metastasis that causes the spread of malignant tumor cells. Porous polymeric materials are widely used to mimic the extracellular matrix (ECM) environment for applications such as three dimensional (3D) cell culturing and tissue engineering. In this paper we report a novel 3D cell culture device based on porous polymeric material to study cancer migration. We fabricated a porous channel on a polymeric chip using a selective ultrasonic foaming method. We demonstrate that a chemical concentration gradient could be established through the porous channel due to the slow diffusion process. We show that significant cell migration could be observed through the porous channel within 1-2 weeks of cell culturing when metastatic M4A4-GFP breast cancer cells were induced by 20% fetal bovine serum (FBS).We also developed a mathematical model to evaluate the diffusivity and concentration gradient through the fabricated porous structure.

  18. Evaluation of the systematic error in using 3D dose calculation in scanning beam proton therapy for lung cancer.

    PubMed

    Li, Heng; Liu, Wei; Park, Peter; Matney, Jason; Liao, Zhongxing; Chang, Joe; Zhang, Xiaodong; Li, Yupeng; Zhu, Ronald X

    2014-09-08

    The objective of this study was to evaluate and understand the systematic error between the planned three-dimensional (3D) dose and the delivered dose to patient in scanning beam proton therapy for lung tumors. Single-field and multifield optimized scanning beam proton therapy plans were generated for ten patients with stage II-III lung cancer with a mix of tumor motion and size. 3D doses in CT datasets for different respiratory phases and the time-weighted average CT, as well as the four-dimensional (4D) doses were computed for both plans. The 3D and 4D dose differences for the targets and different organs at risk were compared using dose-volume histogram (DVH) and voxel-based techniques, and correlated with the extent of tumor motion. The gross tumor volume (GTV) dose was maintained in all 3D and 4D doses, using the internal GTV override technique. The DVH and voxel-based techniques are highly correlated. The mean dose error and the standard deviation of dose error for all target volumes were both less than 1.5% for all but one patient. However, the point dose difference between the 3D and 4D doses was up to 6% for the GTV and greater than 10% for the clinical and planning target volumes. Changes in the 4D and 3D doses were not correlated with tumor motion. The planning technique (single-field or multifield optimized) did not affect the observed systematic error. In conclusion, the dose error in 3D dose calculation varies from patient to patient and does not correlate with lung tumor motion. Therefore, patient-specific evaluation of the 4D dose is important for scanning beam proton therapy for lung tumors.

  19. Simulated and Real Sheet-of-Light 3D Object Scanning Using a-Si:H Thin Film PSD Arrays.

    PubMed

    Contreras, Javier; Tornero, Josep; Ferreira, Isabel; Martins, Rodrigo; Gomes, Luis; Fortunato, Elvira

    2015-11-30

    A MATLAB/SIMULINK software simulation model (structure and component blocks) has been constructed in order to view and analyze the potential of the PSD (Position Sensitive Detector) array concept technology before it is further expanded or developed. This simulation allows changing most of its parameters, such as the number of elements in the PSD array, the direction of vision, the viewing/scanning angle, the object rotation, translation, sample/scan/simulation time, etc. In addition, results show for the first time the possibility of scanning an object in 3D when using an a-Si:H thin film 128 PSD array sensor and hardware/software system. Moreover, this sensor technology is able to perform these scans and render 3D objects at high speeds and high resolutions when using a sheet-of-light laser within a triangulation platform. As shown by the simulation, a substantial enhancement in 3D object profile image quality and realism can be achieved by increasing the number of elements of the PSD array sensor as well as by achieving an optimal position response from the sensor since clearly the definition of the 3D object profile depends on the correct and accurate position response of each detector as well as on the size of the PSD array.

  20. Automatic thermographic scanning with the creation of 3D panoramic views of buildings

    NASA Astrophysics Data System (ADS)

    Ferrarini, G.; Cadelano, G.; Bortolin, A.

    2016-05-01

    Infrared thermography is widely applied to the inspection of building, enabling the identification of thermal anomalies due to the presence of hidden structures, air leakages, and moisture. One of the main advantages of this technique is the possibility to acquire rapidly a temperature map of a surface. However, due to the actual low-resolution of thermal camera and the necessity of scanning surfaces with different orientation, during a building survey it is necessary to take multiple images. In this work a device based on quantitative infrared thermography, called aIRview, has been applied during building surveys to automatically acquire thermograms with a camera mounted on a robotized pan tilt unit. The goal is to perform a first rapid survey of the building that could give useful information for the successive quantitative thermal investigations. For each data acquisition, the instrument covers a rotational field of view of 360° around the vertical axis and up to 180° around the horizontal one. The obtained images have been processed in order to create a full equirectangular projection of the ambient. For this reason the images have been integrated into a web visualization tool, working with web panorama viewers such as Google Street View, creating a webpage where it is possible to have a three dimensional virtual visit of the building. The thermographic data are embedded with the visual imaging and with other sensor data, facilitating the understanding of the physical phenomena underlying the temperature distribution.

  1. 3D printing of tissue-simulating phantoms for calibration of biomedical optical devices

    NASA Astrophysics Data System (ADS)

    Zhao, Zuhua; Zhou, Ximing; Shen, Shuwei; Liu, Guangli; Yuan, Li; Meng, Yuquan; Lv, Xiang; Shao, Pengfei; Dong, Erbao; Xu, Ronald X.

    2016-10-01

    Clinical utility of many biomedical optical devices is limited by the lack of effective and traceable calibration methods. Optical phantoms that simulate biological tissues used for optical device calibration have been explored. However, these phantoms can hardly simulate both structural and optical properties of multi-layered biological tissue. To address this limitation, we develop a 3D printing production line that integrates spin coating, light-cured 3D printing and Fused Deposition Modeling (FDM) for freeform fabrication of optical phantoms with mechanical and optical heterogeneities. With the gel wax Polydimethylsiloxane (PDMS), and colorless light-curable ink as matrix materials, titanium dioxide (TiO2) powder as the scattering ingredient, graphite powder and black carbon as the absorption ingredient, a multilayer phantom with high-precision is fabricated. The absorption and scattering coefficients of each layer are measured by a double integrating sphere system. The results demonstrate that the system has the potential to fabricate reliable tissue-simulating phantoms to calibrate optical imaging devices.

  2. Single-view volumetric PIV via high-resolution scanning, isotropic voxel restructuring and 3D least-squares matching (3D-LSM)

    NASA Astrophysics Data System (ADS)

    Brücker, C.; Hess, D.; Kitzhofer, J.

    2013-02-01

    Scanning PIV as introduced by Brücker (1995 Exp. Fluids 19 255-63, 1996a Appl. Sci. Res. 56 157-79) has been successfully applied in the last 20 years to different flow problems where the frame rate was sufficient to ensure a ‘frozen’ field condition. The limited number of parallel planes however leads typically to an under-sampling in the scan direction in depth; therefore, the spatial resolution in depth is typically considerably lower than the spatial resolution in the plane of the laser sheet (depth resolution = scan shift Δz ≫ pixel unit in object space). In addition, a partial volume averaging effect due to the thickness of the light sheet must be taken into account. Herein, the method is further developed using a high-resolution scanning in combination with a Gaussian regression technique to achieve an isotropic representation of the tracer particles in a voxel-based volume reconstruction with cuboidal voxels. This eliminates the partial volume averaging effect due to light sheet thickness and leads to comparable spatial resolution of the particle field reconstructions in x-, y- and z-axes. In addition, advantage of voxel-based processing with estimations of translation, rotation and shear/strain is taken by using a 3D least-squares matching method, well suited for reconstruction of grey-level pattern fields. The method is discussed in this paper and used to investigate the ring vortex instability at Re = 2500 within a measurement volume of roughly 75 × 75 × 50 mm3 with a spatial resolution of 100 µm/voxel (750 × 750 × 500 voxel elements). The volume has been scanned with a number of 100 light sheets and scan rates of 10 kHz. The results show the growth of the Tsai-Widnall azimuthal instabilities accompanied with a precession of the axis of the vortex ring. Prior to breakdown, secondary instabilities evolve along the core with streamwise oriented striations. The front stagnation point's streamwise distance to the core starts to decrease while

  3. Bifurcation to 3D helical magnetic equilibrium in an axisymmetric toroidal device.

    PubMed

    Bergerson, W F; Auriemma, F; Chapman, B E; Ding, W X; Zanca, P; Brower, D L; Innocente, P; Lin, L; Lorenzini, R; Martines, E; Momo, B; Sarff, J S; Terranova, D

    2011-12-16

    We report the first direct measurement of the internal magnetic field structure associated with a 3D helical equilibrium generated spontaneously in the core of an axisymmetric toroidal plasma containment device. Magnetohydrodynamic equilibrium bifurcation occurs in a reversed-field pinch when the innermost resonant magnetic perturbation grows to a large amplitude, reaching up to 8% of the mean field strength. Magnetic topology evolution is determined by measuring the Faraday effect, revealing that, as the perturbation grows, toroidal symmetry is broken and a helical equilibrium is established.

  4. VIRO 3D: fast three-dimensional full-body scanning for humans and other living objects

    NASA Astrophysics Data System (ADS)

    Stein, Norbert; Minge, Bernhard

    1998-03-01

    The development of a family of partial and whole body scanners provides a complete technology for fully three-dimensional and contact-free scans on human bodies or other living objects within seconds. This paper gives insight into the design and the functional principles of the whole body scanner VIRO 3D operating on the basis of the laser split-beam method. The arrangement of up to 24 camera/laser combinations, thus dividing the area into different camera fields and an all- around sensor configuration travelling in vertical direction allow the complete 360-degree-scan of an object within 6 - 20 seconds. Due to a special calibration process the different sensors are matched and the measured data are combined. Up to 10 million 3D measuring points with a resolution of approximately 1 mm are processed in all coordinate axes to generate a 3D model. By means of high-performance processors in combination with real-time image processing chips the image data from almost any number of sensors can be recorded and evaluated synchronously in video real-time. VIRO 3D scanning systems have already been successfully implemented in various applications and will open up new perspectives in different other fields, ranging from industry, orthopaedic medicine, plastic surgery to art and photography.

  5. Facial expression identification using 3D geometric features from Microsoft Kinect device

    NASA Astrophysics Data System (ADS)

    Han, Dongxu; Al Jawad, Naseer; Du, Hongbo

    2016-05-01

    Facial expression identification is an important part of face recognition and closely related to emotion detection from face images. Various solutions have been proposed in the past using different types of cameras and features. Microsoft Kinect device has been widely used for multimedia interactions. More recently, the device has been increasingly deployed for supporting scientific investigations. This paper explores the effectiveness of using the device in identifying emotional facial expressions such as surprise, smile, sad, etc. and evaluates the usefulness of 3D data points on a face mesh structure obtained from the Kinect device. We present a distance-based geometric feature component that is derived from the distances between points on the face mesh and selected reference points in a single frame. The feature components extracted across a sequence of frames starting and ending by neutral emotion represent a whole expression. The feature vector eliminates the need for complex face orientation correction, simplifying the feature extraction process and making it more efficient. We applied the kNN classifier that exploits a feature component based similarity measure following the principle of dynamic time warping to determine the closest neighbors. Preliminary tests on a small scale database of different facial expressions show promises of the newly developed features and the usefulness of the Kinect device in facial expression identification.

  6. Method for visualization and presentation of priceless old prints based on precise 3D scan

    NASA Astrophysics Data System (ADS)

    Bunsch, Eryk; Sitnik, Robert

    2014-02-01

    Graphic prints and manuscripts constitute main part of the cultural heritage objects created by the most of the known civilizations. Their presentation was always a problem due to their high sensitivity to light and changes of external conditions (temperature, humidity). Today it is possible to use an advanced digitalization techniques for documentation and visualization of mentioned objects. In the situation when presentation of the original heritage object is impossible, there is a need to develop a method allowing documentation and then presentation to the audience of all the aesthetical features of the object. During the course of the project scans of several pages of one of the most valuable books in collection of Museum of Warsaw Archdiocese were performed. The book known as "Great Dürer Trilogy" consists of three series of woodcuts by the Albrecht Dürer. The measurement system used consists of a custom designed, structured light-based, high-resolution measurement head with automated digitization system mounted on the industrial robot. This device was custom built to meet conservators' requirements, especially the lack of ultraviolet or infrared radiation emission in the direction of measured object. Documentation of one page from the book requires about 380 directional measurements which constitute about 3 billion sample points. The distance between the points in the cloud is 20 μm. Provided that the measurement with MSD (measurement sampling density) of 2500 points makes it possible to show to the publicity the spatial structure of this graphics print. An important aspect is the complexity of the software environment created for data processing, in which massive data sets can be automatically processed and visualized. Very important advantage of the software which is using directly clouds of points is the possibility to manipulate freely virtual light source.

  7. Investigation of a Combined Surveying and Scanning Device: The Trimble SX10 Scanning Total Station.

    PubMed

    Lachat, Elise; Landes, Tania; Grussenmeyer, Pierre

    2017-03-31

    Surveying fields from geosciences to infrastructure monitoring make use of a wide range of instruments for accurate 3D geometry acquisition. In many cases, the Terrestrial Laser Scanner (TLS) tends to become an optimal alternative to total station measurements thanks to the high point acquisition rate it offers, but also to ever deeper data processing software functionalities. Nevertheless, traditional surveying techniques are valuable in some kinds of projects. Nowadays, a few modern total stations combine their conventional capabilities with those of a laser scanner in a unique device. The recent Trimble SX10 scanning total station is a survey instrument merging high-speed 3D scanning and the capabilities of an image-assisted total station. In this paper this new instrument is introduced and first compared to state-of-the-art image-assisted total stations. The paper also addresses the topic of various laser scanning projects and the delivered point clouds are compared with those of other TLS. Directly and indirectly georeferenced projects have been carried out and are investigated in this paper, and a polygonal traverse is performed through a building. Comparisons with the results delivered by well-established survey instruments show the reliability of the Trimble SX10 for geodetic work as well as for scanning projects.

  8. Continuous dielectrophoretic particle separation using a microfluidic device with 3D electrodes and vaulted obstacles.

    PubMed

    Jia, Yankai; Ren, Yukun; Jiang, Hongyuan

    2015-08-01

    This paper reports a microfluidic separation device combining 3D electrodes and vaulted obstacles to continuously separate particles experiencing strong positive dielectrophoresis (DEP) from particles experiencing weak positive DEP, or from particles experiencing negative DEP. The separation is achieved by first focusing the particle mixture into a narrow stream by a hydrodynamic focusing flow, and then deviating them into different outlets by AC DEP. The vaulted obstacles facilitate the separation by both increasing the non-uniformity of the electric field, and influencing the particles to move in regions strongly affected by DEP. The 3D electrodes give rise to a spatially non-uniform electric field and extend DEP effect to the channel height. Numerical simulations are performed to investigate the effects of the obstacles on electric field distribution and particle trajectories so as to optimize the obstacle height and compare with the experimental results. The performance of the device is assessed by separating 25 μm gold-coated particles from 10 μm particles in different flow rates by positive DEP and negative DEP, and also separating 25 μm gold-coated particles from yeast cells using only positive DEP. The experimental observation shows a reasonable agreement with numerical simulation results.

  9. Study of 3D printing method for GRIN micro-optics devices

    NASA Astrophysics Data System (ADS)

    Wang, P. J.; Yeh, J. A.; Hsu, W. Y.; Cheng, Y. C.; Lee, W.; Wu, N. H.; Wu, C. Y.

    2016-03-01

    Conventional optical elements are based on either refractive or reflective optics theory to fulfill the design specifications via optics performance data. In refractive optical lenses, the refractive index of materials and radius of curvature of element surfaces determine the optical power and wavefront aberrations so that optical performance can be further optimized iteratively. Although gradient index (GRIN) phenomenon in optical materials is well studied for more than a half century, the optics theory in lens design via GRIN materials is still yet to be comprehensively investigated before realistic GRIN lenses are manufactured. In this paper, 3D printing method for manufacture of micro-optics devices with special features has been studied based on methods reported in the literatures. Due to the additive nature of the method, GRIN lenses in micro-optics devices seem to be readily achievable if a design methodology is available. First, derivation of ray-tracing formulae is introduced for all possible structures in GRIN lenses. Optics simulation program is employed for characterization of GRIN lenses with performance data given by aberration coefficients in Zernike polynomial. Finally, a proposed structure of 3D printing machine is described with conceptual illustration.

  10. An Algorithm to Identify and Localize Suitable Dock Locations from 3-D LiDAR Scans

    DTIC Science & Technology

    2013-05-10

    3-D) LiDARs have proved themselves very useful on many autonomous ground vehicles, such as the Google Driverless Car Project, the DARPA, Defense...appear in a typical point cloud data set, relative to other clusters such as cars , trees, boulders, etc. In this algorithm, these values were

  11. Optimization of transmission and emission scan duration in 3D whole-body PET

    SciTech Connect

    Beyer, T.; Kinahan, P.E.; Townsend, D.W.

    1996-12-31

    Whole-body PET imaging is being increasingly used to identify and localize malignant disease remote from the site of the primary tumor. Patients are typically scanned at multiple contiguous bed positions over an axial length of 75-100 cm. For oncology patients, the total scan duration should not exceed about an hour and therefore only 5-10 minutes of imaging can be performed at each bed position. To minimize the total scan duration, the transmission scan is often omitted and the emission scan reconstructed without attenuation correction. However, whole-body scans reconstructed without attenuation correction can lead to incorrect diagnosis, particularly for tumors located deep within the body. We have performed a series of torso phantom measurements to investigate the optimal partition of scan time between the emission and transmission scans for a fixed total scan duration. We find that a transmission fraction of about 0.4 is optimal for a 5 min and 10 min total acquisition time per bed position. The optimal partition depends on the way the attenuation correction factors are calculated and on the reconstruction algorithm.

  12. Proximity induced superconductivity in the 3D topological insulator HgTe probed with scanning SQUID microscope

    NASA Astrophysics Data System (ADS)

    Sochnikov, Ilya; Kirtley, John R.; Moler, Kathryn A.; Maier, Luis; Bruene, Christoph; Buhmann, Hartmut; Molenkamp, Laurens W.

    2014-03-01

    Inducing superconductivity on the surface of a 3D topological insulator is important for novel broken symmetry phases. However, it is difficult to assess the existence of the surface superconductivity with a single experimental technique. We have used a scanning SQUID microscope to characterize the magnetic properties of hybrid structures made of the 3D topological insulator HgTe and superconducting Nb. The magnetic response of superconducting rings with exotic Josephson junctions reveals the current-phase relation, while measurements of bilayer HgTe/Nb disks reveal the total superfluid density of the hybrid structure. We analyze the degree of skew in the current-phase relation to determine the relative contribution of surface states, and discuss other contributions to the current-phase relation. This work sets an agenda for discussion of the prospects for detection of new broken symmetry phases in 3D topological insulators.

  13. Fast high-resolution 3D total internal reflection fluorescence microscopy by incidence angle scanning and azimuthal averaging

    PubMed Central

    Boulanger, Jérôme; Gueudry, Charles; Münch, Daniel; Cinquin, Bertrand; Paul-Gilloteaux, Perrine; Bardin, Sabine; Guérin, Christophe; Senger, Fabrice; Blanchoin, Laurent; Salamero, Jean

    2014-01-01

    Total internal reflection fluorescence microscopy (TIRFM) is the method of choice to visualize a variety of cellular processes in particular events localized near the plasma membrane of live adherent cells. This imaging technique not relying on particular fluorescent probes provides a high sectioning capability. It is, however, restricted to a single plane. We present here a method based on a versatile design enabling fast multiwavelength azimuthal averaging and incidence angles scanning to computationally reconstruct 3D images sequences. We achieve unprecedented 50-nm axial resolution over a range of 800 nm above the coverslip. We apply this imaging modality to obtain structural and dynamical information about 3D actin architectures. We also temporally decipher distinct Rab11a-dependent exocytosis events in 3D at a rate of seven stacks per second. PMID:25404337

  14. Fast high-resolution 3D total internal reflection fluorescence microscopy by incidence angle scanning and azimuthal averaging.

    PubMed

    Boulanger, Jérôme; Gueudry, Charles; Münch, Daniel; Cinquin, Bertrand; Paul-Gilloteaux, Perrine; Bardin, Sabine; Guérin, Christophe; Senger, Fabrice; Blanchoin, Laurent; Salamero, Jean

    2014-12-02

    Total internal reflection fluorescence microscopy (TIRFM) is the method of choice to visualize a variety of cellular processes in particular events localized near the plasma membrane of live adherent cells. This imaging technique not relying on particular fluorescent probes provides a high sectioning capability. It is, however, restricted to a single plane. We present here a method based on a versatile design enabling fast multiwavelength azimuthal averaging and incidence angles scanning to computationally reconstruct 3D images sequences. We achieve unprecedented 50-nm axial resolution over a range of 800 nm above the coverslip. We apply this imaging modality to obtain structural and dynamical information about 3D actin architectures. We also temporally decipher distinct Rab11a-dependent exocytosis events in 3D at a rate of seven stacks per second.

  15. Structured Light Based 3d Scanning for Specular Surface by the Combination of Gray Code and Phase Shifting

    NASA Astrophysics Data System (ADS)

    Zhang, Yujia; Yilmaz, Alper

    2016-06-01

    Surface reconstruction using coded structured light is considered one of the most reliable techniques for high-quality 3D scanning. With a calibrated projector-camera stereo system, a light pattern is projected onto the scene and imaged by the camera. Correspondences between projected and recovered patterns are computed in the decoding process, which is used to generate 3D point cloud of the surface. However, the indirect illumination effects on the surface, such as subsurface scattering and interreflections, will raise the difficulties in reconstruction. In this paper, we apply maximum min-SW gray code to reduce the indirect illumination effects of the specular surface. We also analysis the errors when comparing the maximum min-SW gray code and the conventional gray code, which justifies that the maximum min-SW gray code has significant superiority to reduce the indirect illumination effects. To achieve sub-pixel accuracy, we project high frequency sinusoidal patterns onto the scene simultaneously. But for specular surface, the high frequency patterns are susceptible to decoding errors. Incorrect decoding of high frequency patterns will result in a loss of depth resolution. Our method to resolve this problem is combining the low frequency maximum min-SW gray code and the high frequency phase shifting code, which achieves dense 3D reconstruction for specular surface. Our contributions include: (i) A complete setup of the structured light based 3D scanning system; (ii) A novel combination technique of the maximum min-SW gray code and phase shifting code. First, phase shifting decoding with sub-pixel accuracy. Then, the maximum min-SW gray code is used to resolve the ambiguity resolution. According to the experimental results and data analysis, our structured light based 3D scanning system enables high quality dense reconstruction of scenes with a small number of images. Qualitative and quantitative comparisons are performed to extract the advantages of our new

  16. Sensor for In-Motion Continuous 3D Shape Measurement Based on Dual Line-Scan Cameras

    PubMed Central

    Sun, Bo; Zhu, Jigui; Yang, Linghui; Yang, Shourui; Guo, Yin

    2016-01-01

    The acquisition of three-dimensional surface data plays an increasingly important role in the industrial sector. Numerous 3D shape measurement techniques have been developed. However, there are still limitations and challenges in fast measurement of large-scale objects or high-speed moving objects. The innovative line scan technology opens up new potentialities owing to the ultra-high resolution and line rate. To this end, a sensor for in-motion continuous 3D shape measurement based on dual line-scan cameras is presented. In this paper, the principle and structure of the sensor are investigated. The image matching strategy is addressed and the matching error is analyzed. The sensor has been verified by experiments and high-quality results are obtained. PMID:27869731

  17. Study of Shortwave Spectra in Fully 3D Environment: Synergy Between Scanning Radars and Spectral Radiation Measurements

    NASA Technical Reports Server (NTRS)

    Wiscombe, Warren J.

    2012-01-01

    The main theme for our research is the understanding and closure of the surface spectral shortwave radiation problem in fully 3D cloud situations by combining the new ARM scanning radars, shortwave spectrometers, and microwave radiometers with the arsenal of radiative transfer tools developed by our group. In particular, we define first a large number of cloudy test cases spanning all 3D possibilities not just the customary uniform-overcast ones. Second, for each case, we define a "Best Estimate of Clouds That Affect Shortwave Radiation" using all relevant ARM instruments, notably the new scanning radars, and contribute this to the ARM Archive. Third, we test the ASR-signature radiative transfer model RRTMG_SW for those cases, focusing on the near-IR because of long-standing problems in this spectral region, and work with the developers to improve RRTMG_SW in order to increase its penetration into the modeling community.

  18. Sensor for In-Motion Continuous 3D Shape Measurement Based on Dual Line-Scan Cameras.

    PubMed

    Sun, Bo; Zhu, Jigui; Yang, Linghui; Yang, Shourui; Guo, Yin

    2016-11-18

    The acquisition of three-dimensional surface data plays an increasingly important role in the industrial sector. Numerous 3D shape measurement techniques have been developed. However, there are still limitations and challenges in fast measurement of large-scale objects or high-speed moving objects. The innovative line scan technology opens up new potentialities owing to the ultra-high resolution and line rate. To this end, a sensor for in-motion continuous 3D shape measurement based on dual line-scan cameras is presented. In this paper, the principle and structure of the sensor are investigated. The image matching strategy is addressed and the matching error is analyzed. The sensor has been verified by experiments and high-quality results are obtained.

  19. Benchmarking Naval Shipbuilding With 3D Laser Scanning, Additive Manufacturing, and Collaborative Product Lifecycle Management

    DTIC Science & Technology

    2016-04-30

    methods use subtractive processes (e.g., machining), but AM builds a 3D object by gradually adding successive layers of material that are laid down...practice. For example, RFID is frequently used to control construction material flows (CoreRFID, 2008). Damen Industries is developing animated... build -up part • Variety of possible materials (plastic, titanium) & methods (e.g. for material bonding) • No dominant method, materials

  20. Accurate 3d Scanning of Damaged Ancient Greek Inscriptions for Revealing Weathered Letters

    NASA Astrophysics Data System (ADS)

    Papadaki, A. I.; Agrafiotis, P.; Georgopoulos, A.; Prignitz, S.

    2015-02-01

    In this paper two non-invasive non-destructive alternative techniques to the traditional and invasive technique of squeezes are presented alongside with specialized developed processing methods, aiming to help the epigraphists to reveal and analyse weathered letters in ancient Greek inscriptions carved in masonry or marble. The resulting 3D model would serve as a detailed basis for the epigraphists to try to decipher the inscription. The data were collected by using a Structured Light scanner. The creation of the final accurate three dimensional model is a complicated procedure requiring large computation cost and human effort. It includes the collection of geometric data in limited space and time, the creation of the surface, the noise filtering and the merging of individual surfaces. The use of structured light scanners is time consuming and requires costly hardware and software. Therefore an alternative methodology for collecting 3D data of the inscriptions was also implemented for reasons of comparison. Hence, image sequences from varying distances were collected using a calibrated DSLR camera aiming to reconstruct the 3D scene through SfM techniques in order to evaluate the efficiency and the level of precision and detail of the obtained reconstructed inscriptions. Problems in the acquisition processes as well as difficulties in the alignment step and mesh optimization are also encountered. A meta-processing framework is proposed and analysed. Finally, the results of processing and analysis and the different 3D models are critically inspected and then evaluated by a specialist in terms of accuracy, quality and detail of the model and the capability of revealing damaged and "hidden" letters.

  1. Novel eye-safe line scanning 3D laser-radar

    NASA Astrophysics Data System (ADS)

    Eberle, B.; Kern, Tobias; Hammer, Marcus; Schwanke, Ullrich; Nowak, Heinrich

    2014-10-01

    Today, the civil market provides quite a number of different 3D-Sensors covering ranges up to 1 km. Typically these sensors are based on single element detectors which suffer from the drawback of spatial resolution at larger distances. Tasks demanding reliable object classification at long ranges can be fulfilled only by sensors consisting of detector arrays. They ensure sufficient frame rates and high spatial resolution. Worldwide there are many efforts in developing 3D-detectors, based on two-dimensional arrays. This paper presents first results on the performance of a recently developed 3D imaging laser radar sensor, working in the short wave infrared (SWIR) at 1.5 μm. It consists of a novel Cadmium Mercury Telluride (CMT) linear array APD detector with 384x1 elements at a pitch of 25 μm, developed by AIM Infrarot Module GmbH. The APD elements are designed to work in the linear (non-Geiger) mode. Each pixel will provide the time of flight measurement, and, due to the linear detection mode, allowing the detection of three successive echoes. The resolution in depth is 15 cm, the maximum repetition rate is 4 kHz. We discuss various sensor concepts regarding possible applications and their dependence on system parameters like field of view, frame rate, spatial resolution and range of operation.

  2. An Investigation into the Use of 3D Scanning and Printing Technologies in the Navy Collaborative Product Lifecycle Management

    DTIC Science & Technology

    2013-12-01

    photogrammetry approach (indicating higher accuracy), and that resolution of 0.4mm for laser scanning compared well with resolution of 1.0 mm for... photogrammetry (Aguilar et al., 2009). Thus, COTS 3D scanners selected was as or more accurate and high-resolution as the more expensive photogrammetry ...2008). 3DS can be an inexpensive process, with COTS scanners performing as well as expensive photogrammetry machines for some applications (Aguilar

  3. Visualization of Mesenchymal Stromal Cells in 2Dand 3D-Cultures by Scanning Electron Microscopy with Lanthanide Contrasting.

    PubMed

    Novikov, I A; Vakhrushev, I V; Antonov, E N; Yarygin, K N; Subbot, A M

    2017-02-01

    Mesenchymal stromal cells from deciduous teeth in 2D- and 3D-cultures on culture plastic, silicate glass, porous polystyrene, and experimental polylactoglycolide matrices were visualized by scanning electron microscopy with lanthanide contrasting. Supravital staining of cell cultures with a lanthanide-based dye (neodymium chloride) preserved normal cell morphology and allowed assessment of the matrix properties of the carriers. The developed approach can be used for the development of biomaterials for tissue engineering.

  4. Computer-aided diagnosis of pulmonary nodules on CT scans: segmentation and classification using 3D active contours.

    PubMed

    Way, Ted W; Hadjiiski, Lubomir M; Sahiner, Berkman; Chan, Heang-Ping; Cascade, Philip N; Kazerooni, Ella A; Bogot, Naama; Zhou, Chuan

    2006-07-01

    We are developing a computer-aided diagnosis (CAD) system to classify malignant and benign lung nodules found on CT scans. A fully automated system was designed to segment the nodule from its surrounding structured background in a local volume of interest (VOI) and to extract image features for classification. Image segmentation was performed with a three-dimensional (3D) active contour (AC) method. A data set of 96 lung nodules (44 malignant, 52 benign) from 58 patients was used in this study. The 3D AC model is based on two-dimensional AC with the addition of three new energy components to take advantage of 3D information: (1) 3D gradient, which guides the active contour to seek the object surface, (2) 3D curvature, which imposes a smoothness constraint in the z direction, and (3) mask energy, which penalizes contours that grow beyond the pleura or thoracic wall. The search for the best energy weights in the 3D AC model was guided by a simplex optimization method. Morphological and gray-level features were extracted from the segmented nodule. The rubber band straightening transform (RBST) was applied to the shell of voxels surrounding the nodule. Texture features based on run-length statistics were extracted from the RBST image. A linear discriminant analysis classifier with stepwise feature selection was designed using a second simplex optimization to select the most effective features. Leave-one-case-out resampling was used to train and test the CAD system. The system achieved a test area under the receiver operating characteristic curve (A(z)) of 0.83 +/- 0.04. Our preliminary results indicate that use of the 3D AC model and the 3D texture features surrounding the nodule is a promising approach to the segmentation and classification of lung nodules with CAD. The segmentation performance of the 3D AC model trained with our data set was evaluated with 23 nodules available in the Lung Image Database Consortium (LIDC). The lung nodule volumes segmented by the 3D

  5. Computer-aided diagnosis of pulmonary nodules on CT scans: Segmentation and classification using 3D active contours

    PubMed Central

    Way, Ted W.; Hadjiiski, Lubomir M.; Sahiner, Berkman; Chan, Heang-Ping; Cascade, Philip N.; Kazerooni, Ella A.; Bogot, Naama; Zhou, Chuan

    2009-01-01

    We are developing a computer-aided diagnosis (CAD) system to classify malignant and benign lung nodules found on CT scans. A fully automated system was designed to segment the nodule from its surrounding structured background in a local volume of interest (VOI) and to extract image features for classification. Image segmentation was performed with a three-dimensional (3D) active contour (AC) method. A data set of 96 lung nodules (44 malignant, 52 benign) from 58 patients was used in this study. The 3D AC model is based on two-dimensional AC with the addition of three new energy components to take advantage of 3D information: (1) 3D gradient, which guides the active contour to seek the object surface, (2) 3D curvature, which imposes a smoothness constraint in the z direction, and (3) mask energy, which penalizes contours that grow beyond the pleura or thoracic wall. The search for the best energy weights in the 3D AC model was guided by a simplex optimization method. Morphological and gray-level features were extracted from the segmented nodule. The rubber band straightening transform (RBST) was applied to the shell of voxels surrounding the nodule. Texture features based on run-length statistics were extracted from the RBST image. A linear discriminant analysis classifier with stepwise feature selection was designed using a second simplex optimization to select the most effective features. Leave-one-case-out resampling was used to train and test the CAD system. The system achieved a test area under the receiver operating characteristic curve (Az) of 0.83±0.04. Our preliminary results indicate that use of the 3D AC model and the 3D texture features surrounding the nodule is a promising approach to the segmentation and classification of lung nodules with CAD. The segmentation performance of the 3D AC model trained with our data set was evaluated with 23 nodules available in the Lung Image Database Consortium (LIDC). The lung nodule volumes segmented by the 3D AC

  6. Height control of laser metal-wire deposition based on iterative learning control and 3D scanning

    NASA Astrophysics Data System (ADS)

    Heralić, Almir; Christiansson, Anna-Karin; Lennartson, Bengt

    2012-09-01

    Laser Metal-wire Deposition is an additive manufacturing technique for solid freeform fabrication of fully dense metal structures. The technique is based on robotized laser welding and wire filler material, and the structures are built up layer by layer. The deposition process is, however, sensitive to disturbances and thus requires continuous monitoring and adjustments. In this work a 3D scanning system is developed and integrated with the robot control system for automatic in-process control of the deposition. The goal is to ensure stable deposition, by means of choosing a correct offset of the robot in the vertical direction, and obtaining a flat surface, for each deposited layer. The deviations in the layer height are compensated by controlling the wire feed rate on next deposition layer, based on the 3D scanned data, by means of iterative learning control. The system is tested through deposition of bosses, which is expected to be a typical application for this technique in the manufacture of jet engine components. The results show that iterative learning control including 3D scanning is a suitable method for automatic deposition of such structures. This paper presents the equipment, the control strategy and demonstrates the proposed approach with practical experiments.

  7. Continuous-scanning laser Doppler vibrometry: Extensions to arbitrary areas, multi-frequency and 3D capture

    SciTech Connect

    Weekes, B.; Ewins, D.; Acciavatti, F.

    2014-05-27

    To date, differing implementations of continuous scan laser Doppler vibrometry have been demonstrated by various academic institutions, but since the scan paths were defined using step or sine functions from function generators, the paths were typically limited to 1D line scans or 2D areas such as raster paths or Lissajous trajectories. The excitation was previously often limited to a single frequency due to the specific signal processing performed to convert the scan data into an ODS. In this paper, a configuration of continuous-scan laser Doppler vibrometry is demonstrated which permits scanning of arbitrary areas, with the benefit of allowing multi-frequency/broadband excitation. Various means of generating scan paths to inspect arbitrary areas are discussed and demonstrated. Further, full 3D vibration capture is demonstrated by the addition of a range-finding facility to the described configuration, and iteratively relocating a single scanning laser head. Here, the range-finding facility was provided by a Microsoft Kinect, an inexpensive piece of consumer electronics.

  8. Continuous-scanning laser Doppler vibrometry: Extensions to arbitrary areas, multi-frequency and 3D capture

    NASA Astrophysics Data System (ADS)

    Weekes, B.; Ewins, D.; Acciavatti, F.

    2014-05-01

    To date, differing implementations of continuous scan laser Doppler vibrometry have been demonstrated by various academic institutions, but since the scan paths were defined using step or sine functions from function generators, the paths were typically limited to 1D line scans or 2D areas such as raster paths or Lissajous trajectories. The excitation was previously often limited to a single frequency due to the specific signal processing performed to convert the scan data into an ODS. In this paper, a configuration of continuous-scan laser Doppler vibrometry is demonstrated which permits scanning of arbitrary areas, with the benefit of allowing multi-frequency/broadband excitation. Various means of generating scan paths to inspect arbitrary areas are discussed and demonstrated. Further, full 3D vibration capture is demonstrated by the addition of a range-finding facility to the described configuration, and iteratively relocating a single scanning laser head. Here, the range-finding facility was provided by a Microsoft Kinect, an inexpensive piece of consumer electronics.

  9. Multi-frequency, 3D ODS measurement by continuous scan laser Doppler vibrometry

    NASA Astrophysics Data System (ADS)

    Weekes, Ben; Ewins, David

    2015-06-01

    Continuous scan laser Doppler vibrometry (CSLDV) is a technique which has been described and explored in the literature for over two decades, but remains niche compared to SLDV inspection by a series of discrete-point measurements. This is in part because of the unavoidable phenomenon of laser speckle, which deteriorates signal quality when velocity data is captured from a moving spot measurement. Further, applicability of CSLDV has typically been limited to line scans and rectangular areas by the application of sine, step, or ramp functions to the scanning mirrors which control the location of the measurement laser spot. In this paper it is shown that arbitrary functions to scan any area can easily be derived from a basic calibration routine, equivalent to the calibration performed in conventional discrete-point laser vibrometry. This is extended by performing the same scan path upon a test surface from three independent locations of the laser head, and decomposing the three sets of one-dimensional deflection shapes into a single set of three-dimensional deflection shapes. The test was performed with multi-sine excitation, yielding 34 operating deflection shapes from each scan.

  10. Development and characterization of 3D, nano-confined multicellular constructs for advanced biohybrid devices.

    SciTech Connect

    Kaehr, Bryan James

    2011-09-01

    This is the final report for the President Harry S. Truman Fellowship in National Security Science and Engineering (LDRD project 130813) awarded to Dr. Bryan Kaehr from 2008-2011. Biological chemistries, cells, and integrated systems (e.g., organisms, ecologies, etc.) offer important lessons for the design of synthetic strategies and materials. The desire to both understand and ultimately improve upon biological processes has been a driving force for considerable scientific efforts worldwide. However, to impart the useful properties of biological systems into modern devices and materials requires new ideas and technologies. The research herein addresses aspects of these issues through the development of (1) a rapid-prototyping methodology to build 3D bio-interfaces and catalytic architectures, (2) a quantitative method to measure cell/material mechanical interactions in situ and at the microscale, and (3) a breakthrough approach to generate functional biocomposites from bacteria and cultured cells.

  11. 3D sensitive voxel detector of ionizing radiation based on Timepix device

    NASA Astrophysics Data System (ADS)

    Soukup, P.; Jakubek, J.; Vykydal, Z.

    2011-01-01

    Position sensitive detectors are evolving towards higher segmentation geometries from 0D (single pad) over 1D (strip) to 2D (pixel) detectors. Each step has brought up substantial expansion in the field of applications. The next logical step in this evolution is to design a 3D, i.e. voxel detector. The voxel detector can be constructed from 2D volume element detectors arranged in layers forming a 3D matrix of sensitive elements — voxels. Such detectors can effectively record tracks of energetic particles. By proper analysis of these tracks it is possible to determine the type, direction and energy of the primary particle. One of the prominent applications of such device is in the localization and identification of gamma and neutron sources in the environment. It can be also used for emission and transmission radiography in many fields where standard imagers are currently utilized. The qualitative properties of current imagers such as: spatial resolution, efficiency, directional sensitivity, energy sensitivity and selectivity (background suppression) can be improved. The first prototype of a voxel detector was built using a number of Timepix devices. Timepix is hybrid semiconductor detector consisting of a segmented semiconductor sensor bump-bonded to a readout chip. Each sensor contains 256x256 square pixels of 55 μm size. The voxel detector prototype was successfully tested to prove the concept functionality. The detector has a modular architecture with a daisy chain connection of the individual detector layers. This permits easy rearrangement due to its modularity, while keeping a single readout system for a variable number of detector layers. A limitation of this approach is the relatively large inter-layer distance (4 mm) compared to the pixel thickness (0.3 mm). Therefore the next step in the design is to decrease the space between the 2D detectors.

  12. Soft tissue response to mandibular advancement using 3D CBCT scanning.

    PubMed

    Almeida, R C; Cevidanes, L H S; Carvalho, F A R; Motta, A T; Almeida, M A O; Styner, M; Turvey, T; Proffit, W R; Phillips, C

    2011-04-01

    This prospective longitudinal study assessed the 3D soft tissue changes following mandibular advancement surgery. Cranial base registration was performed for superimposition of virtual models built from cone beam computed tomography (CBCT) volumes. Displacements at the soft and hard tissue chin (n = 20), lower incisors and lower lip (n = 21) were computed for presurgery to splint removal (4-6-week surgical outcome), presurgery to 1 year postsurgery (1-year surgical outcome), and splint removal to 1 year postsurgery (postsurgical adaptation). Qualitative evaluations of color maps illustrated the surgical changes and postsurgical adaptations, but only the lower lip showed statistically significant postsurgical adaptations. Soft and hard tissue chin changes were significantly correlated for each of the intervals evaluated: presurgery to splint removal (r = 0.92), presurgery to 1 year postsurgery (r = 0.86), and splint removal to 1 year postsurgery (r = 0.77). A statistically significant correlation between lower incisor and lower lip was found only between presurgery and 1 year postsurgery (r = 0.55). At 1 year after surgery, 31% of the lower lip changes were explained by changes in the lower incisor position while 73% of the soft tissue chin changes were explained by the hard chin. This study suggests that 3D soft tissue response to mandibular advancement surgery is markedly variable.

  13. How to Create a 3D Model from Scanned Data in 5 Easy Steps

    NASA Technical Reports Server (NTRS)

    Hagen, Richard

    2017-01-01

    Additive manufacturing is a cost effective way to generate copies of damaged parts for demonstrations. Integrating scanned data of a damaged area into an existing model may be challenging. However, using the relatively inexpensive Nettfab software (from one can generate a "watertight" model that is easy to print.

  14. Uncertainty studies of topographical measurements on steel surface corrosion by 3D scanning electron microscopy.

    PubMed

    Kang, K W; Pereda, M D; Canafoglia, M E; Bilmes, P; Llorente, C; Bonetto, R

    2012-02-01

    Pitting corrosion is a damage mechanism quite serious and dangerous in both carbon steel boiler tubes for power plants which are vital to most industries and stainless steels for orthopedic human implants whose demand, due to the increase of life expectation and rate of traffic accidents, has sharply increased. Reliable methods to characterize this kind of damage are becoming increasingly necessary, when trying to evaluate the advance of damage and to establish the best procedures for component inspection in order to determine remaining lives and failure mitigation. A study about the uncertainties on the topographies of corrosion pits from 3D SEM images, obtained at low magnifications (where errors are greater) and different stage tilt angles were carried out using an in-house software previously developed. Additionally, measurements of pit depths on biomaterial surfaces, subjected to two different surface treatments on stainless steels, were carried out. The different depth distributions observed were in agreement with electrochemical measurements.

  15. Vertical profiles of the 3-D wind velocity retrieved from multiple wind lidars performing triple range-height-indicator scans

    DOE PAGES

    Debnath, Mithu; Iungo, G. Valerio; Ashton, Ryan; ...

    2017-02-06

    Vertical profiles of 3-D wind velocity are retrieved from triple range-height-indicator (RHI) scans performed with multiple simultaneous scanning Doppler wind lidars. This test is part of the eXperimental Planetary boundary layer Instrumentation Assessment (XPIA) campaign carried out at the Boulder Atmospheric Observatory. The three wind velocity components are retrieved and then compared with the data acquired through various profiling wind lidars and high-frequency wind data obtained from sonic anemometers installed on a 300 m meteorological tower. The results show that the magnitude of the horizontal wind velocity and the wind direction obtained from the triple RHI scans are generally retrieved with goodmore » accuracy. However, poor accuracy is obtained for the evaluation of the vertical velocity, which is mainly due to its typically smaller magnitude and to the error propagation connected with the data retrieval procedure and accuracy in the experimental setup.« less

  16. Vertical profiles of the 3-D wind velocity retrieved from multiple wind lidars performing triple range-height-indicator scans

    SciTech Connect

    Debnath, Mithu; Iungo, G. Valerio; Ashton, Ryan; Brewer, W. Alan; Choukulkar, Aditya; Delgado, Ruben; Lundquist, Julie K.; Shaw, William J.; Wilczak, James M.; Wolfe, Daniel

    2017-01-01

    Vertical profiles of 3-D wind velocity are retrieved from triple range-height-indicator (RHI) scans performed with multiple simultaneous scanning Doppler wind lidars. This test is part of the eXperimental Planetary boundary layer Instrumentation Assessment (XPIA) campaign carried out at the Boulder Atmospheric Observatory. The three wind velocity components are retrieved and then compared with the data acquired through various profiling wind lidars and high-frequency wind data obtained from sonic anemometers installed on a 300 m meteorological tower. The results show that the magnitude of the horizontal wind velocity and the wind direction obtained from the triple RHI scans are generally retrieved with good accuracy. However, poor accuracy is obtained for the evaluation of the vertical velocity, which is mainly due to its typically smaller magnitude and to the error propagation connected with the data retrieval procedure and accuracy in the experimental setup.

  17. Vertical profiles of the 3-D wind velocity retrieved from multiple wind lidars performing triple range-height-indicator scans

    NASA Astrophysics Data System (ADS)

    Debnath, Mithu; Valerio Iungo, G.; Ashton, Ryan; Brewer, W. Alan; Choukulkar, Aditya; Delgado, Ruben; Lundquist, Julie K.; Shaw, William J.; Wilczak, James M.; Wolfe, Daniel

    2017-02-01

    Vertical profiles of 3-D wind velocity are retrieved from triple range-height-indicator (RHI) scans performed with multiple simultaneous scanning Doppler wind lidars. This test is part of the eXperimental Planetary boundary layer Instrumentation Assessment (XPIA) campaign carried out at the Boulder Atmospheric Observatory. The three wind velocity components are retrieved and then compared with the data acquired through various profiling wind lidars and high-frequency wind data obtained from sonic anemometers installed on a 300 m meteorological tower. The results show that the magnitude of the horizontal wind velocity and the wind direction obtained from the triple RHI scans are generally retrieved with good accuracy. However, poor accuracy is obtained for the evaluation of the vertical velocity, which is mainly due to its typically smaller magnitude and to the error propagation connected with the data retrieval procedure and accuracy in the experimental setup.

  18. Semi-automated extraction and delineation of 3D roads of street scene from mobile laser scanning point clouds

    NASA Astrophysics Data System (ADS)

    Yang, Bisheng; Fang, Lina; Li, Jonathan

    2013-05-01

    Accurate 3D road information is important for applications such as road maintenance and virtual 3D modeling. Mobile laser scanning (MLS) is an efficient technique for capturing dense point clouds that can be used to construct detailed road models for large areas. This paper presents a method for extracting and delineating roads from large-scale MLS point clouds. The proposed method partitions MLS point clouds into a set of consecutive "scanning lines", which each consists of a road cross section. A moving window operator is used to filter out non-ground points line by line, and curb points are detected based on curb patterns. The detected curb points are tracked and refined so that they are both globally consistent and locally similar. To evaluate the validity of the proposed method, experiments were conducted using two types of street-scene point clouds captured by Optech's Lynx Mobile Mapper System. The completeness, correctness, and quality of the extracted roads are over 94.42%, 91.13%, and 91.3%, respectively, which proves the proposed method is a promising solution for extracting 3D roads from MLS point clouds.

  19. Hand Controlled Manipulation of Single Molecules via a Scanning Probe Microscope with a 3D Virtual Reality Interface.

    PubMed

    Leinen, Philipp; Green, Matthew F B; Esat, Taner; Wagner, Christian; Tautz, F Stefan; Temirov, Ruslan

    2016-10-02

    Considering organic molecules as the functional building blocks of future nanoscale technology, the question of how to arrange and assemble such building blocks in a bottom-up approach is still open. The scanning probe microscope (SPM) could be a tool of choice; however, SPM-based manipulation was until recently limited to two dimensions (2D). Binding the SPM tip to a molecule at a well-defined position opens an opportunity of controlled manipulation in 3D space. Unfortunately, 3D manipulation is largely incompatible with the typical 2D-paradigm of viewing and generating SPM data on a computer. For intuitive and efficient manipulation we therefore couple a low-temperature non-contact atomic force/scanning tunneling microscope (LT NC-AFM/STM) to a motion capture system and fully immersive virtual reality goggles. This setup permits "hand controlled manipulation" (HCM), in which the SPM tip is moved according to the motion of the experimenter's hand, while the tip trajectories as well as the response of the SPM junction are visualized in 3D. HCM paves the way to the development of complex manipulation protocols, potentially leading to a better fundamental understanding of nanoscale interactions acting between molecules on surfaces. Here we describe the setup and the steps needed to achieve successful hand-controlled molecular manipulation within the virtual reality environment.

  20. Increase of Readability and Accuracy of 3d Models Using Fusion of Close Range Photogrammetry and Laser Scanning

    NASA Astrophysics Data System (ADS)

    Gašparović, M.; Malarić, I.

    2012-07-01

    The development of laser scanning technology has opened a new page in geodesy and enabled an entirely new way of presenting data. Products obtained by the method of laser scanning are used in many sciences, as well as in archaeology. It should be noted that 3D models of archaeological artefacts obtained by laser scanning are fully measurable, written in 1:1 scale and have high accuracy. On the other hand, texture and RGB values of the surface of the object obtained by a laser scanner have lower resolution and poorer radiometric characteristics in relation to the textures captured with a digital camera. Scientific research and the goal of this paper are to increase the accuracy and readability of the 3D model with textures obtained with a digital camera. Laser scanning was performed with triangulation scanner of high accuracy, Vivid 9i (Konica Minolta), while for photogrammetric recording digital camera Nikon D90 with a lens of fixed focal length 20 mm, was used. It is important to stress that a posteriori accuracy score of the global registration of point clouds in the form of the standard deviation was ± 0.136 mm while the average distance was only ± 0.080 mm. Also research has proven that the quality projection texture model increases readability. Recording of archaeological artefacts and making their photorealistic 3D model greatly contributes to archaeology as a science, accelerates processing and reconstruction of the findings. It also allows the presentation of findings to the general public, not just to the experts.

  1. Fast 3D in vivo swept-source optical coherence tomography using a two-axis MEMS scanning micromirror

    NASA Astrophysics Data System (ADS)

    Kumar, Karthik; Condit, Jonathan C.; McElroy, Austin; Kemp, Nate J.; Hoshino, Kazunori; Milner, Thomas E.; Zhang, Xiaojing

    2008-04-01

    We report on a fibre-based forward-imaging swept-source optical coherence tomography system using a high-reflectivity two-axis microelectromechanical scanning mirror for high-speed 3D in vivo visualization of cellular-scale architecture of biological specimens. The scanning micromirrors, based on electrostatic staggered vertical comb drive actuators, can provide ± 9° of optical deflection on both rotation axes and uniform reflectivity of greater than 90% over the range of imaging wavelengths (1260-1360 nm), allowing for imaging turbid samples with good signal-to-noise ratio. The wavelength-swept laser, scanning over 100 nm spectrum at 20 kHz rate, enables fast image acquisition at 10.2 million voxels s-1 (for 3D imaging) or 40 frames s-1 (for 2D imaging with 500 transverse pixels per image) with 8.6 µm axial resolution. Lateral resolution of 12.5 µm over 3 mm field of view in each lateral direction is obtained using ZEMAX optical simulations for the lateral beam scanning system across the scanning angle range of the 500 µm × 700 µm micromirror. We successfully acquired en face and tomographic images of rigid structures (scanning micromirror), in vitro biological samples (onion peels and pickle slices) and in vivo images of human epidermis over 2 × 1 × 4 mm3 imaging volume in real time at faster-than-video 2D frame rates. The results indicate that our system framework may be suitable for image-guided minimally invasive examination of various diseased tissues.

  2. A 3D Freehand Ultrasound System for Multi-view Reconstructions from Sparse 2D Scanning Planes

    PubMed Central

    2011-01-01

    Background A significant limitation of existing 3D ultrasound systems comes from the fact that the majority of them work with fixed acquisition geometries. As a result, the users have very limited control over the geometry of the 2D scanning planes. Methods We present a low-cost and flexible ultrasound imaging system that integrates several image processing components to allow for 3D reconstructions from limited numbers of 2D image planes and multiple acoustic views. Our approach is based on a 3D freehand ultrasound system that allows users to control the 2D acquisition imaging using conventional 2D probes. For reliable performance, we develop new methods for image segmentation and robust multi-view registration. We first present a new hybrid geometric level-set approach that provides reliable segmentation performance with relatively simple initializations and minimum edge leakage. Optimization of the segmentation model parameters and its effect on performance is carefully discussed. Second, using the segmented images, a new coarse to fine automatic multi-view registration method is introduced. The approach uses a 3D Hotelling transform to initialize an optimization search. Then, the fine scale feature-based registration is performed using a robust, non-linear least squares algorithm. The robustness of the multi-view registration system allows for accurate 3D reconstructions from sparse 2D image planes. Results Volume measurements from multi-view 3D reconstructions are found to be consistently and significantly more accurate than measurements from single view reconstructions. The volume error of multi-view reconstruction is measured to be less than 5% of the true volume. We show that volume reconstruction accuracy is a function of the total number of 2D image planes and the number of views for calibrated phantom. In clinical in-vivo cardiac experiments, we show that volume estimates of the left ventricle from multi-view reconstructions are found to be in better

  3. Study of 3D remote sensing system based on optical scanning holography

    NASA Astrophysics Data System (ADS)

    Zhao, Shihu; Yan, Lei

    2009-06-01

    High-precision and real-time remote sensing imaging system is an important part of remote sensing development. Holography is a method of wave front record and recovery which was presented by Dennis Gabor. As a new kind of holography techniques, Optical scanning holography (OSH) and remote sensing imaging are intended to be combined together and applied in acquisition and interference measurement of remote sensing. The key principles and applicability of OSH are studied and the mathematic relation between Fresnel Zone Plate number, numerical aperture and object distance was deduced, which are proved to be feasible for OSH to apply in large scale remote sensing. At last, a new three-dimensional reflected OSH remote sensing imaging system is designed with the combination of scanning technique to record hologram patterns of large scale remote sensing scenes. This scheme is helpful for expanding OSH technique to remote sensing in future.

  4. Full-color holographic 3D imaging system using color optical scanning holography

    NASA Astrophysics Data System (ADS)

    Kim, Hayan; Kim, You Seok; Kim, Taegeun

    2016-06-01

    We propose a full-color holographic three-dimensional imaging system that composes a recording stage, a transmission and processing stage and reconstruction stage. In recording stage, color optical scanning holography (OSH) records the complex RGB holograms of an object. In transmission and processing stage, the recorded complex RGB holograms are transmitted to the reconstruction stage after conversion to off-axis RGB holograms. In reconstruction stage, the off-axis RGB holograms are reconstructed optically.

  5. Scanning laser optical computed tomography system for large volume 3D dosimetry

    NASA Astrophysics Data System (ADS)

    Dekker, Kurtis H.; Battista, Jerry J.; Jordan, Kevin J.

    2017-04-01

    Stray light causes artifacts in optical computed tomography (CT) that negatively affect the accuracy of radiation dosimetry in gels or solids. Scatter effects are exacerbated by a large dosimeter volume, which is desirable for direct verification of modern radiotherapy treatment plans such as multiple-isocenter radiosurgery. The goal in this study was to design and characterize an optical CT system that achieves high accuracy primary transmission measurements through effective stray light rejection, while maintaining sufficient scan speed for practical application. We present an optical imaging platform that uses a galvanometer mirror for horizontal scanning, and a translation stage for vertical movement of a laser beam and small area detector for minimal stray light production and acceptance. This is coupled with a custom lens-shaped optical CT aquarium for parallel ray sampling of projections. The scanner images 15 cm diameter, 12 cm height cylindrical volumes at 0.33 mm resolution in approximately 30 min. Attenuation coefficients reconstructed from CT scans agreed with independent cuvette measurements within 2% for both absorbing and scattering solutions as well as small 1.25 cm diameter absorbing phantoms placed within a large, scattering medium that mimics gel. Excellent linearity between the optical CT scanner and the independent measurement was observed for solutions with between 90% and 2% transmission. These results indicate that the scanner should achieve highly accurate dosimetry of large volume dosimeters in a reasonable timeframe for clinical application to radiotherapy dose verification procedures.

  6. Scanning laser optical computed tomography system for large volume 3D dosimetry.

    PubMed

    Dekker, Kurtis H; Battista, Jerry J; Jordan, Kevin J

    2017-04-07

    Stray light causes artifacts in optical computed tomography (CT) that negatively affect the accuracy of radiation dosimetry in gels or solids. Scatter effects are exacerbated by a large dosimeter volume, which is desirable for direct verification of modern radiotherapy treatment plans such as multiple-isocenter radiosurgery. The goal in this study was to design and characterize an optical CT system that achieves high accuracy primary transmission measurements through effective stray light rejection, while maintaining sufficient scan speed for practical application. We present an optical imaging platform that uses a galvanometer mirror for horizontal scanning, and a translation stage for vertical movement of a laser beam and small area detector for minimal stray light production and acceptance. This is coupled with a custom lens-shaped optical CT aquarium for parallel ray sampling of projections. The scanner images 15 cm diameter, 12 cm height cylindrical volumes at 0.33 mm resolution in approximately 30 min. Attenuation coefficients reconstructed from CT scans agreed with independent cuvette measurements within 2% for both absorbing and scattering solutions as well as small 1.25 cm diameter absorbing phantoms placed within a large, scattering medium that mimics gel. Excellent linearity between the optical CT scanner and the independent measurement was observed for solutions with between 90% and 2% transmission. These results indicate that the scanner should achieve highly accurate dosimetry of large volume dosimeters in a reasonable timeframe for clinical application to radiotherapy dose verification procedures.

  7. 3D segmentation of abdominal aorta from CT-scan and MR images.

    PubMed

    Duquette, Anthony Adam; Jodoin, Pierre-Marc; Bouchot, Olivier; Lalande, Alain

    2012-06-01

    We designed a generic method for segmenting the aneurismal sac of an abdominal aortic aneurysm (AAA) both from multi-slice MR and CT-scan examinations. It is a semi-automatic method requiring little human intervention and based on graph cut theory to segment the lumen interface and the aortic wall of AAAs. Our segmentation method works independently on MRI and CT-scan volumes and has been tested on a 44 patient dataset and 10 synthetic images. Segmentation and maximum diameter estimation were compared to manual tracing from 4 experts. An inter-observer study was performed in order to measure the variability range of a human observer. Based on three metrics (the maximum aortic diameter, the volume overlap and the Hausdorff distance) the variability of the results obtained by our method is shown to be similar to that of a human operator, both for the lumen interface and the aortic wall. As will be shown, the average distance obtained with our method is less than one standard deviation away from each expert, both for healthy subjects and for patients with AAA. Our semi-automatic method provides reliable contours of the abdominal aorta from CT-scan or MRI, allowing rapid and reproducible evaluations of AAA.

  8. Photo-Based 3d Scanning VS. Laser Scanning - Competitive Data Acquisition Methods for Digital Terrain Modelling of Steep Mountain Slopes

    NASA Astrophysics Data System (ADS)

    Kolecka, N.

    2011-09-01

    The paper presents how terrestrial laser scanning (TLS) and terrestrial digital photogrammetry were used to create a 3D model of a steep mountain wall. Terrestrial methods of data acquisition are the most suitable for such relief, as the most effective registration is perpendicular to the surface. First, various aspects of photo-based scanning and laser scanning were discussed. The general overview of both technologies was followed by the description of a case study of the western wall of the Kościelec Mountain (2155 m). The case study area is one of the most interesting and popular rock climbing areas in the Polish High Tatra Mts. The wall is about 300 meters high, has varied relief and some parts are overhung. Triangular irregular mesh was chosen to represent the true- 3D surface with its complicated relief. To achieve a more smooth result for visualization NURBS curves and surfaces were utilized. Both 3D models were then compared to the standard DTM of the Tatra Mountains in TIN format, obtained from aerial photographs (0.2 m ground pixel size). The results showed that both TLS and terrestrial photogrammetry had similar accuracy and level of detail and could effectively supplement very high resolution DTMs of the mountain areas.

  9. A novel MR-guided interventional device for 3D circumferential access to breast tissue

    PubMed Central

    Smith, Matthew; Zhai, Xu; Harter, Ray; Sisney, Gale; Elezaby, Mai; Fain, Sean

    2008-01-01

    MRI is rapidly growing as a tool for image-guided procedures in the breast such as needle localizations, biopsy, and cryotherapy. The ability of MRI to resolve small (<1 cm) lesions allows earlier detection and diagnosis than with ultrasound. Most MR-guidance methods perform a two-dimensional compression of the breast that distorts tissue anatomy and limits medial access. This work presents a system for localizing breast lesions with 360° access to breast tissue. A novel system has been developed to perform breast lesion localization using MR guidance that uses a 3D radial coordinate system with four degrees of freedom. The device is combined with a novel breast RF coil for improved signal to noise and rotates 360° around the breast to allow medial, lateral, superior, and inferior access minimizing insertion depth to the target. Coil performance was evaluated using a human volunteer by comparing signal to noise from both the developed breast RF coil and a commercial seven-channel breast coil. The system was tested with a breast-shaped gel phantom containing randomly distributed MR-visible targets. MR-compatible localization needles were used to demonstrate the accuracy and feasibility of the concept for breast biopsy. Localization results were classified based on the relationship between the final needle tip position and the lesion. A 3D bladder concept was also tested using animal tissue to evaluate the device’s ability to immobilize deformable breast tissue during a needle insertion. The RF breast coil provided signal to noise values comparable to a seven-channel breast coil. The needle tip was in contact with the targeted lesion in 89% (25∕28) of all the trials and 100% (6∕6) of the trials with targeted lesions >6 mm. Target lesions were 3–4 mm in diameter for 47% (13∕28), 5–6 mm in diameter for 32% (9∕28), and over 6 mm in diameter for 21% (6∕28) of the trials, respectively. The 3D bladder concept was shown to immobilize a deformable animal

  10. MEVA - An Interactive Visualization Application for Validation of Multifaceted Meteorological Data with Multiple 3D Devices

    PubMed Central

    Helbig, Carolin; Bilke, Lars; Bauer, Hans-Stefan; Böttinger, Michael; Kolditz, Olaf

    2015-01-01

    Background To achieve more realistic simulations, meteorologists develop and use models with increasing spatial and temporal resolution. The analyzing, comparing, and visualizing of resulting simulations becomes more and more challenging due to the growing amounts and multifaceted character of the data. Various data sources, numerous variables and multiple simulations lead to a complex database. Although a variety of software exists suited for the visualization of meteorological data, none of them fulfills all of the typical domain-specific requirements: support for quasi-standard data formats and different grid types, standard visualization techniques for scalar and vector data, visualization of the context (e.g., topography) and other static data, support for multiple presentation devices used in modern sciences (e.g., virtual reality), a user-friendly interface, and suitability for cooperative work. Methods and Results Instead of attempting to develop yet another new visualization system to fulfill all possible needs in this application domain, our approach is to provide a flexible workflow that combines different existing state-of-the-art visualization software components in order to hide the complexity of 3D data visualization tools from the end user. To complete the workflow and to enable the domain scientists to interactively visualize their data without advanced skills in 3D visualization systems, we developed a lightweight custom visualization application (MEVA - multifaceted environmental data visualization application) that supports the most relevant visualization and interaction techniques and can be easily deployed. Specifically, our workflow combines a variety of different data abstraction methods provided by a state-of-the-art 3D visualization application with the interaction and presentation features of a computer-games engine. Our customized application includes solutions for the analysis of multirun data, specifically with respect to data

  11. 3D electro-thermal Monte Carlo study of transport in confined silicon devices

    NASA Astrophysics Data System (ADS)

    Mohamed, Mohamed Y.

    The simultaneous explosion of portable microelectronics devices and the rapid shrinking of microprocessor size have provided a tremendous motivation to scientists and engineers to continue the down-scaling of these devices. For several decades, innovations have allowed components such as transistors to be physically reduced in size, allowing the famous Moore's law to hold true. As these transistors approach the atomic scale, however, further reduction becomes less probable and practical. As new technologies overcome these limitations, they face new, unexpected problems, including the ability to accurately simulate and predict the behavior of these devices, and to manage the heat they generate. This work uses a 3D Monte Carlo (MC) simulator to investigate the electro-thermal behavior of quasi-one-dimensional electron gas (1DEG) multigate MOSFETs. In order to study these highly confined architectures, the inclusion of quantum correction becomes essential. To better capture the influence of carrier confinement, the electrostatically quantum-corrected full-band MC model has the added feature of being able to incorporate subband scattering. The scattering rate selection introduces quantum correction into carrier movement. In addition to the quantum effects, scaling introduces thermal management issues due to the surge in power dissipation. Solving these problems will continue to bring improvements in battery life, performance, and size constraints of future devices. We have coupled our electron transport Monte Carlo simulation to Aksamija's phonon transport so that we may accurately and efficiently study carrier transport, heat generation, and other effects at the transistor level. This coupling utilizes anharmonic phonon decay and temperature dependent scattering rates. One immediate advantage of our coupled electro-thermal Monte Carlo simulator is its ability to provide an accurate description of the spatial variation of self-heating and its effect on non

  12. A multinational deployment of 3D laser scanning to study craniofacial dysmorphology in fetal alcohol spectrum disorders

    NASA Astrophysics Data System (ADS)

    Rogers, Jeff; Wernert, Eric; Moore, Elizabeth; Ward, Richard; Wetherill, Leah F.; Foroud, Tatiana

    2007-01-01

    Craniofacial anthropometry (the measurement and analysis of head and face dimensions) has been used to assess and describe abnormal craniofacial variation (dysmorphology) and the facial phenotype in many medical syndromes. Traditionally, anthropometry measurements have been collected by the direct application of calipers and tape measures to the subject's head and face, and can suffer from inaccuracies due to restless subjects, erroneous landmark identification, clinician variability, and other forms of human error. Three-dimensional imaging technologies promise a more effective alternative that separates the acquisition and measurement phases to reduce these variabilities while also enabling novel measurements and longitudinal analysis of subjects. Indiana University (IU) is part of an international consortium of researchers studying fetal alcohol spectrum disorders (FASD). Fetal alcohol exposure results in predictable craniofacial dysmorphologies, and anthropometry has been proven to be an effective diagnosis tool for the condition. IU is leading a project to study the use of 3D surface scanning to acquire anthropometry data in order to more accurately diagnose FASD, especially in its milder forms. This paper describes our experiences in selecting, verifying, supporting, and coordinating a set of 3D scanning systems for use in collecting facial scans and anthropometric data from around the world.

  13. Detection accuracy of condylar bony defects in Promax 3D cone beam CT images scanned with different protocols

    PubMed Central

    Zhang, Z-L; Cheng, J-G; Li, G; Shi, X-Q; Zhang, J-Z; Zhang, Z-Y; Ma, X-C

    2013-01-01

    Objectives: To investigate and compare the detection accuracy of bony defects on the condylar surface of the temporomandibular joint (TMJ) in cone beam CT (CBCT) images scanned with standard and large view protocols on the same machine. Methods: 21 dry human skulls with 42 TMJs were scanned with the large view and standard view protocols of the CBCT scanner Promax 3D (Planmeca, Helsinki, Finland). Seven observers evaluated all the images for the presence or absence of defects on the surface of the condyle. Using the macroscopic examination of condylar defects as the gold standard, receiver operating characteristic (ROC) analysis was performed. Results: Macroscopic examination revealed that, of the 42 condyles, 18 were normal and 24 had a defect on the surface of the condyles. Areas under the ROC curves for the large view and the standard view group of CBCT images were 0.739 and 0.720, respectively, and no significant difference was found between the two groups of images (p = 0.902). Neither the interobserver nor the intraobserver variability were significant. Conclusions: The two scanning protocols provided by the CBCT scanner Promax 3D were reliable and comparable with detection of condylar defects. PMID:23420852

  14. Continuous versus step-by-step scanning mode of a novel 3D scanner for CyberKnife measurements.

    PubMed

    Al Kafi, M Abdullah; Mwidu, Umar; Moftah, Belal

    2015-11-01

    The purpose of the study is to investigate the continuous versus step-by-step scanning mode of a commercial circular 3D scanner for commissioning measurements of a robotic stereotactic radiosurgery system. The 3D scanner was used for profile measurements in step-by-step and continuous modes with the intent of comparing the two scanning modes for consistency. The profile measurements of in-plane, cross-plane, 15 degree, and 105 degree were performed for both fixed cones and Iris collimators at depth of maximum dose and at 10cm depth. For CyberKnife field size, penumbra, flatness and symmetry analysis, it was observed that the measurements with continuous mode, which can be up to 6 times faster than step-by-step mode, are comparable and produce scans nearly identical to step-by-step mode. When compared with centered step-by-step mode data, a fully processed continuous mode data gives rise to maximum of 0.50% and 0.60% symmetry and flatness difference respectfully for all the fixed cones and Iris collimators studied.

  15. Foot roll-over evaluation based on 3D dynamic foot scan.

    PubMed

    Samson, William; Van Hamme, Angèle; Sanchez, Stéphane; Chèze, Laurence; Van Sint Jan, Serge; Feipel, Véronique

    2014-01-01

    Foot roll-over is commonly analyzed to evaluate gait pathologies. The current study utilized a dynamic foot scanner (DFS) to analyze foot roll-over. The right feet of ten healthy subjects were assessed during gait trials with a DFS system integrated into a walkway. A foot sole picture was computed by vertically projecting points from the 3D foot shape which were lower than a threshold height of 15 mm. A 'height' value of these projected points was determined; corresponding to the initial vertical coordinates prior to projection. Similar to pedobarographic analysis, the foot sole picture was segmented into anatomical regions of interest (ROIs) to process mean height (average of height data by ROI) and projected surface (area of the projected foot sole by ROI). Results showed that these variables evolved differently to plantar pressure data previously reported in the literature, mainly due to the specificity of each physical quantity (millimeters vs Pascals). Compared to plantar pressure data arising from surface contact by the foot, the current method takes into account the whole plantar aspect of the foot, including the parts that do not make contact with the support surface. The current approach using height data could contribute to a better understanding of specific aspects of foot motion during walking, such as plantar arch height and the windlass mechanism. Results of this study show the underlying method is reliable. Further investigation is required to validate the DFS measurements within a clinical context, prior to implementation into clinical practice.

  16. Parallel graph search: application to intraretinal layer segmentation of 3D macular OCT scans

    NASA Astrophysics Data System (ADS)

    Lee, Kyungmoo; Abràmoff, Michael D.; Garvin, Mona K.; Sonka, Milan

    2012-02-01

    Image segmentation is of paramount importance for quantitative analysis of medical image data. Recently, a 3-D graph search method which can detect globally optimal interacting surfaces with respect to the cost function of volumetric images has been introduced, and its utility demonstrated in several application areas. Although the method provides excellent segmentation accuracy, its limitation is a slow processing speed when many surfaces are simultaneously segmented in large volumetric datasets. Here, we propose a novel method of parallel graph search, which overcomes the limitation and allows the quick detection of multiple surfaces. To demonstrate the obtained performance with respect to segmentation accuracy and processing speedup, the new approach was applied to retinal optical coherence tomography (OCT) image data and compared with the performance of the former non-parallel method. Our parallel graph search methods for single and double surface detection are approximately 267 and 181 times faster than the original graph search approach in 5 macular OCT volumes (200 x 5 x 1024 voxels) acquired from the right eyes of 5 normal subjects. The resulting segmentation differences were small as demonstrated by the mean unsigned differences between the non-parallel and parallel methods of 0.0 +/- 0.0 voxels (0.0 +/- 0.0 μm) and 0.27 +/- 0.34 voxels (0.53 +/- 0.66 μm) for the single- and dual-surface approaches, respectively.

  17. Morphologic 3D scanning of fallopian tubes to assist ovarian cancer diagnosis

    NASA Astrophysics Data System (ADS)

    Madore, Wendy-Julie; De Montigny, Etienne; Deschênes, Andréanne; Benboujja, Fouzi; Leduc, Mikael; Mes-Masson, Anne-Marie; Provencher, Diane M.; Rahimi, Kurosh; Boudoux, Caroline; Godbout, Nicolas

    2016-02-01

    Pathological evaluation of the fallopian tubes is an important diagnostic result but tumors can be missed using routine approaches. As the majority of high-grade serous ovarian cancers are now believed to originate in the fallopian tubes, pathological examination should include in a thorough examination of the excised ovaries and fallopian tubes. We present an dedicated imaging system for diagnostic exploration of human fallopian tubes. This system is based on optical coherence tomography (OCT), a laser imaging modality giving access to sub- epithelial tissue architecture. This system produces cross-sectional images up to 3 mm in depth, with a lateral resolution of ≍15μm and an axial resolution of ≍12μm. An endoscopic single fiber probe was developed to fit in a human fallopian tube. This 1.2 mm probe produces 3D volume data of the entire inner tube within a few minutes. To demonstrate the clinical potential of OCT for lesion identification, we studied 5 different ovarian lesions and healthy fallopian tubes. We imaged 52 paraffin-embedded human surgical specimens with a benchtop system and compared these images with histology slides. We also imaged and compared healthy oviducts from 3 animal models to find one resembling the human anatomy and to develop a functional ex vivo imaging procedure with the endoscopic probe. We also present an update on an ongoing clinical pilot study on women undergoing prophylactic or diagnostic surgery in which we image ex vivo fallopian tubes with the endoscopic probe.

  18. Development of kinematic 3D laser scanning system for indoor mapping and as-built BIM using constrained SLAM.

    PubMed

    Jung, Jaehoon; Yoon, Sanghyun; Ju, Sungha; Heo, Joon

    2015-10-16

    The growing interest and use of indoor mapping is driving a demand for improved data-acquisition facility, efficiency and productivity in the era of the Building Information Model (BIM). The conventional static laser scanning method suffers from some limitations on its operability in complex indoor environments, due to the presence of occlusions. Full scanning of indoor spaces without loss of information requires that surveyors change the scanner position many times, which incurs extra work for registration of each scanned point cloud. Alternatively, a kinematic 3D laser scanning system, proposed herein, uses line-feature-based Simultaneous Localization and Mapping (SLAM) technique for continuous mapping. Moreover, to reduce the uncertainty of line-feature extraction, we incorporated constrained adjustment based on an assumption made with respect to typical indoor environments: that the main structures are formed of parallel or orthogonal line features. The superiority of the proposed constrained adjustment is its reduction for uncertainties of the adjusted lines, leading to successful data association process. In the present study, kinematic scanning with and without constrained adjustment were comparatively evaluated in two test sites, and the results confirmed the effectiveness of the proposed system. The accuracy of the 3D mapping result was additionally evaluated by comparison with the reference points acquired by a total station: the Euclidean average distance error was 0.034 m for the seminar room and 0.043 m for the corridor, which satisfied the error tolerance for point cloud acquisition (0.051 m) according to the guidelines of the General Services Administration for BIM accuracy.

  19. Development of Kinematic 3D Laser Scanning System for Indoor Mapping and As-Built BIM Using Constrained SLAM

    PubMed Central

    Jung, Jaehoon; Yoon, Sanghyun; Ju, Sungha; Heo, Joon

    2015-01-01

    The growing interest and use of indoor mapping is driving a demand for improved data-acquisition facility, efficiency and productivity in the era of the Building Information Model (BIM). The conventional static laser scanning method suffers from some limitations on its operability in complex indoor environments, due to the presence of occlusions. Full scanning of indoor spaces without loss of information requires that surveyors change the scanner position many times, which incurs extra work for registration of each scanned point cloud. Alternatively, a kinematic 3D laser scanning system, proposed herein, uses line-feature-based Simultaneous Localization and Mapping (SLAM) technique for continuous mapping. Moreover, to reduce the uncertainty of line-feature extraction, we incorporated constrained adjustment based on an assumption made with respect to typical indoor environments: that the main structures are formed of parallel or orthogonal line features. The superiority of the proposed constrained adjustment is its reduction for uncertainties of the adjusted lines, leading to successful data association process. In the present study, kinematic scanning with and without constrained adjustment were comparatively evaluated in two test sites, and the results confirmed the effectiveness of the proposed system. The accuracy of the 3D mapping result was additionally evaluated by comparison with the reference points acquired by a total station: the Euclidean average distance error was 0.034 m for the seminar room and 0.043 m for the corridor, which satisfied the error tolerance for point cloud acquisition (0.051 m) according to the guidelines of the General Services Administration for BIM accuracy. PMID:26501292

  20. Technical note: Reliability of Suchey-Brooks and Buckberry-Chamberlain methods on 3D visualizations from CT and laser scans.

    PubMed

    Villa, Chiara; Buckberry, Jo; Cattaneo, Cristina; Lynnerup, Niels

    2013-05-01

    Previous studies have reported that the ageing method of Suchey-Brooks (pubic bone) and some of the features applied by Lovejoy et al. and Buckberry-Chamberlain (auricular surface) can be confidently performed on 3D visualizations from CT-scans. In this study, seven observers applied the Suchey-Brooks and the Buckberry-Chamberlain methods on 3D visualizations based on CT-scans and, for the first time, on 3D visualizations from laser scans. We examined how the bone features can be evaluated on 3D visualizations and whether the different modalities (direct observations of bones, 3D visualization from CT-scan and from laser scans) are alike to different observers. We found the best inter-observer agreement for the bones versus 3D visualizations, with the highest values for the auricular surface. Between the 3D modalities, less variability was obtained for the 3D laser visualizations. Fair inter-observer agreement was obtained in the evaluation of the pubic bone in all modalities. In 3D visualizations of the auricular surfaces, transverse organization and apical changes could be evaluated, although with high inter-observer variability; micro-, macroporosity and surface texture were very difficult to score. In conclusion, these methods were developed for dry bones, where they perform best. The Suchey-Brooks method can be applied on 3D visualizations from CT or laser, but with less accuracy than on dry bone. The Buckberry-Chamberlain method should be modified before application on 3D visualizations. Future investigation should focus on a different approach and different features: 3D laser scans could be analyzed with mathematical approaches and sub-surface features should be explored on CT-scans.

  1. Scanning all-fiber-optic endomicroscopy system for 3D nonlinear optical imaging of biological tissues

    PubMed Central

    Wu, Yicong; Leng, Yuxin; Xi, Jiefeng; Li, Xingde

    2009-01-01

    An extremely compact all-fiber-optic scanning endomicroscopy system was developed for two-photon fluorescence (TPF) and second harmonic generation (SHG) imaging of biological samples. A conventional double-clad fiber (DCF) was employed in the endomicroscope for single-mode femtosecond pulse delivery, multimode nonlinear optical signals collection and fast two-dimensional scanning. A single photonic bandgap fiber (PBF) with negative group velocity dispersion at two-photon excitation wavelength (i.e. ~810 nm) was used for pulse prechirping in replacement of a bulky grating/lens-based pulse stretcher. The combined use of DCF and PBF in the endomicroscopy system made the endomicroscope basically a plug-and-play unit. The excellent imaging ability of the extremely compact all-fiber-optic nonlinear optical endomicroscopy system was demonstrated by SHG imaging of rat tail tendon and depth-resolved TPF imaging of epithelial tissues stained with acridine orange. The preliminary results suggested the promising potential of this extremely compact all-fiber-optic endomicroscopy system for real-time assessment of both epithelial and stromal structures in luminal organs. PMID:19434122

  2. A fast 3D image simulation algorithm of moving target for scanning laser radar

    NASA Astrophysics Data System (ADS)

    Li, Jicheng; Shi, Zhiguang; Chen, Xiao; Chen, Dong

    2014-10-01

    Scanning Laser Radar has been widely used in many military and civil areas. Usually there are relative movements between the target and the radar, so the moving target image modeling and simulation is an important research content in the field of signal processing and system design of scan-imaging laser radar. In order to improve the simulation speed and hold the accuracy of the image simulation simultaneously, a novel fast simulation algorithm is proposed in this paper. Firstly, for moving target or varying scene, an inequation that can judge the intersection relations between the pixel and target bins is obtained by deriving the projection of target motion trajectories on the image plane. Then, by utilizing the time subdivision and approximate treatments, the potential intersection relations of pixel and target bins are determined. Finally, the goal of reducing the number of intersection operations could be achieved by testing all the potential relations and finding which of them is real intersection. To test the method's performance, we perform computer simulations of both the new proposed algorithm and a literature's algorithm for six targets. The simulation results show that the two algorithm yield the same imaging result, whereas the number of intersection operations of former is equivalent to only 1% of the latter, and the calculation efficiency increases a hundredfold. The novel simulation acceleration idea can be applied extensively in other more complex application environments and provide equally acceleration effect. It is very suitable for the case to produce a great large number of laser radar images.

  3. 3D-Laser-Scanning Technique Applied to Bulk Density Measurements of Apollo Lunar Samples

    NASA Technical Reports Server (NTRS)

    Macke, R. J.; Kent, J. J.; Kiefer, W. S.; Britt, D. T.

    2015-01-01

    In order to better interpret gravimetric data from orbiters such as GRAIL and LRO to understand the subsurface composition and structure of the lunar crust, it is import to have a reliable database of the density and porosity of lunar materials. To this end, we have been surveying these physical properties in both lunar meteorites and Apollo lunar samples. To measure porosity, both grain density and bulk density are required. For bulk density, our group has historically utilized sub-mm bead immersion techniques extensively, though several factors have made this technique problematic for our work with Apollo samples. Samples allocated for measurement are often smaller than optimal for the technique, leading to large error bars. Also, for some samples we were required to use pure alumina beads instead of our usual glass beads. The alumina beads were subject to undesirable static effects, producing unreliable results. Other investigators have tested the use of 3d laser scanners on meteorites for measuring bulk volumes. Early work, though promising, was plagued with difficulties including poor response on dark or reflective surfaces, difficulty reproducing sharp edges, and large processing time for producing shape models. Due to progress in technology, however, laser scanners have improved considerably in recent years. We tested this technique on 27 lunar samples in the Apollo collection using a scanner at NASA Johnson Space Center. We found it to be reliable and more precise than beads, with the added benefit that it involves no direct contact with the sample, enabling the study of particularly friable samples for which bead immersion is not possible

  4. 3-D confocal laser scanning microscopy used in morphometric analysis of rat Purkinje cell dendritic spines after chronic ethanol consumption.

    PubMed

    Wenisch, S; Fortmann, B; Steinmetz, T; Kriete, A; Leiser, R; Bitsch, I

    1998-12-01

    A confocal laser scanning microscope (with a 543 nm laser) was used for imaging rat Purkinje cell dendritic spines at high 3-D resolution. In a nutritionally controlled study of the rat, 5 months of ethanol consumption was demonstrated to alter the spines of Purkinje cell dendrites in rat cerebellum. Intact spines showed significant elongation after ethanol exposure, whereas this neuromorphological alteration could not be detected in controls. Spine elongation could be regarded as compensative growth of spines in search of new synaptic contacts due to alcohol induced cell loss.

  5. Parallel deconvolution of large 3D images obtained by confocal laser scanning microscopy.

    PubMed

    Pawliczek, Piotr; Romanowska-Pawliczek, Anna; Soltys, Zbigniew

    2010-03-01

    Various deconvolution algorithms are often used for restoration of digital images. Image deconvolution is especially needed for the correction of three-dimensional images obtained by confocal laser scanning microscopy. Such images suffer from distortions, particularly in the Z dimension. As a result, reliable automatic segmentation of these images may be difficult or even impossible. Effective deconvolution algorithms are memory-intensive and time-consuming. In this work, we propose a parallel version of the well-known Richardson-Lucy deconvolution algorithm developed for a system with distributed memory and implemented with the use of Message Passing Interface (MPI). It enables significantly more rapid deconvolution of two-dimensional and three-dimensional images by efficiently splitting the computation across multiple computers. The implementation of this algorithm can be used on professional clusters provided by computing centers as well as on simple networks of ordinary PC machines.

  6. Comparative assessment of 3D surface scanning systems in breast plastic and reconstructive surgery.

    PubMed

    Patete, Paolo; Eder, Maximilian; Raith, Stefan; Volf, Alexander; Kovacs, Laszlo; Baroni, Guido

    2013-10-01

    In this work, we compared accuracy, repeatability, and usability in breast surface imaging of 2 commercial surface scanning systems and a hand-held laser surface scanner prototype coupled with a patient's motion acquisition and compensation methodology. The accuracy of the scanners was assessed on an anthropomorphic phantom, and to evaluate the usability of the scanners on humans, thorax surface images of 3 volunteers were acquired. Both the intrascanner repeatability and the interscanner comparative accuracy were assessed. The results showed surface-to-surface distance errors inferior to 1 mm and to 2 mm, respectively, for the 2 commercial scanners and for the prototypical one. Moreover, comparable performances of the 3 scanners were found when used for acquiring the breast surface. On the whole, this study demonstrated that handheld laser surface scanners coupled with subject motion compensation methods lend themselves as competitive technologies for human body surface modeling.

  7. A 3D character animation engine for multimodal interaction on mobile devices

    NASA Astrophysics Data System (ADS)

    Sandali, Enrico; Lavagetto, Fabio; Pisano, Paolo

    2005-03-01

    Talking virtual characters are graphical simulations of real or imaginary persons that enable natural and pleasant multimodal interaction with the user, by means of voice, eye gaze, facial expression and gestures. This paper presents an implementation of a 3D virtual character animation and rendering engine, compliant with the MPEG-4 standard, running on Symbian-based SmartPhones. Real-time animation of virtual characters on mobile devices represents a challenging task, since many limitations must be taken into account with respect to processing power, graphics capabilities, disk space and execution memory size. The proposed optimization techniques allow to overcome these issues, guaranteeing a smooth and synchronous animation of facial expressions and lip movements on mobile phones such as Sony-Ericsson's P800 and Nokia's 6600. The animation engine is specifically targeted to the development of new "Over The Air" services, based on embodied conversational agents, with applications in entertainment (interactive story tellers), navigation aid (virtual guides to web sites and mobile services), news casting (virtual newscasters) and education (interactive virtual teachers).

  8. Incorporation of 3-D Scanning Lidar Data into Google Earth for Real-time Air Pollution Observation

    NASA Astrophysics Data System (ADS)

    Chiang, C.; Nee, J.; Das, S.; Sun, S.; Hsu, Y.; Chiang, H.; Chen, S.; Lin, P.; Chu, J.; Su, C.; Lee, W.; Su, L.; Chen, C.

    2011-12-01

    3-D Differential Absorption Scanning Lidar (DIASL) system has been designed with small size, light weight, and suitable for installation in various vehicles and places for monitoring of air pollutants and displays a detailed real-time temporal and spatial variability of trace gases via the Google Earth. The fast scanning techniques and visual information can rapidly identify the locations and sources of the polluted gases and assess the most affected areas. It is helpful for Environmental Protection Agency (EPA) to protect the people's health and abate the air pollution as quickly as possible. The distributions of the atmospheric pollutants and their relationship with local metrological parameters measured with ground based instruments will also be discussed. Details will be presented in the upcoming symposium.

  9. See-Through Imaging of Laser-Scanned 3d Cultural Heritage Objects Based on Stochastic Rendering of Large-Scale Point Clouds

    NASA Astrophysics Data System (ADS)

    Tanaka, S.; Hasegawa, K.; Okamoto, N.; Umegaki, R.; Wang, S.; Uemura, M.; Okamoto, A.; Koyamada, K.

    2016-06-01

    We propose a method for the precise 3D see-through imaging, or transparent visualization, of the large-scale and complex point clouds acquired via the laser scanning of 3D cultural heritage objects. Our method is based on a stochastic algorithm and directly uses the 3D points, which are acquired using a laser scanner, as the rendering primitives. This method achieves the correct depth feel without requiring depth sorting of the rendering primitives along the line of sight. Eliminating this need allows us to avoid long computation times when creating natural and precise 3D see-through views of laser-scanned cultural heritage objects. The opacity of each laser-scanned object is also flexibly controllable. For a laser-scanned point cloud consisting of more than 107 or 108 3D points, the pre-processing requires only a few minutes, and the rendering can be executed at interactive frame rates. Our method enables the creation of cumulative 3D see-through images of time-series laser-scanned data. It also offers the possibility of fused visualization for observing a laser-scanned object behind a transparent high-quality photographic image placed in the 3D scene. We demonstrate the effectiveness of our method by applying it to festival floats of high cultural value. These festival floats have complex outer and inner 3D structures and are suitable for see-through imaging.

  10. Characterizing microscale aluminum composite layer properties on silicon solar cells with hybrid 3D scanning force measurements.

    PubMed

    Bae, Sung-Kuk; Choi, Beomjoon; Chung, Haseung; Shin, Seungwon; Song, Hee-eun; Seo, Jung Hwan

    2016-03-07

    This article presents a novel technique to estimate the mechanical properties of the aluminum composite layer on silicon solar cells by using a hybrid 3-dimensional laser scanning force measurement (3-D LSFM) system. The 3-D LSFM system measures the material properties of sub-layers constituting a solar cell. This measurement is critical for realizing high-efficient ultra-thin solar cells. The screen-printed aluminum layer, which significantly affects the bowing phenomenon, is separated from the complete solar cell by removing the silicon (Si) layer with deep reactive ion etching. An elastic modulus of ~15.1 GPa and a yield strength of ~35.0 MPa for the aluminum (Al) composite layer were obtained by the 3-D LSFM system. In experiments performed for 6-inch Si solar cells, the bowing distances decreased from 12.02 to 1.18 mm while the Si layer thicknesses increased from 90 to 190 μm. These results are in excellent agreement with the theoretical predictions for ultra-thin Si thickness (90 μm) based on the obtained Al composite layer properties.

  11. Optical measurement of the dynamic strain field of a fan blade using a 3D scanning vibrometer

    NASA Astrophysics Data System (ADS)

    Vuye, C.; Vanlanduit, S.; Presezniak, F.; Steenackers, G.; Guillaume, P.

    2011-07-01

    Understanding the origin of the stress and strain distribution is crucial to increase the durability of components under dynamic loading. Numerical simulations based on finite element (FE) models help with this understanding but must be validated by real measured data. Updating the FE model using the measured data is often the next step in the design process. In this paper the recently developed 3D-scanning laser doppler vibrometer (3D-SLDV) is used to measure the 3D-displacement of a fan blade, which is then used to calculate the dynamic strain distributions. The measurement principle and experimental setup are discussed thoroughly. The experimental results are validated by using a FE model on the one hand and strain gage measurements on the other. It is shown that this technique is capable of measuring normal strain far below 1 microstrain. This technique has the potential to fill in the gap of accurately measuring small (full-field) normal and shear strains at both low and high frequencies, where other optical techniques (and strain gages) would certainly fail.

  12. Characterizing microscale aluminum composite layer properties on silicon solar cells with hybrid 3D scanning force measurements

    NASA Astrophysics Data System (ADS)

    Bae, Sung-Kuk; Choi, Beomjoon; Chung, Haseung; Shin, Seungwon; Song, Hee-Eun; Seo, Jung Hwan

    2016-03-01

    This article presents a novel technique to estimate the mechanical properties of the aluminum composite layer on silicon solar cells by using a hybrid 3-dimensional laser scanning force measurement (3-D LSFM) system. The 3-D LSFM system measures the material properties of sub-layers constituting a solar cell. This measurement is critical for realizing high-efficient ultra-thin solar cells. The screen-printed aluminum layer, which significantly affects the bowing phenomenon, is separated from the complete solar cell by removing the silicon (Si) layer with deep reactive ion etching. An elastic modulus of ~15.1 GPa and a yield strength of ~35.0 MPa for the aluminum (Al) composite layer were obtained by the 3-D LSFM system. In experiments performed for 6-inch Si solar cells, the bowing distances decreased from 12.02 to 1.18 mm while the Si layer thicknesses increased from 90 to 190 μm. These results are in excellent agreement with the theoretical predictions for ultra-thin Si thickness (90 μm) based on the obtained Al composite layer properties.

  13. Characterizing microscale aluminum composite layer properties on silicon solar cells with hybrid 3D scanning force measurements

    PubMed Central

    Bae, Sung-Kuk; Choi, Beomjoon; Chung, Haseung; Shin, Seungwon; Song, Hee-eun; Seo, Jung Hwan

    2016-01-01

    This article presents a novel technique to estimate the mechanical properties of the aluminum composite layer on silicon solar cells by using a hybrid 3-dimensional laser scanning force measurement (3-D LSFM) system. The 3-D LSFM system measures the material properties of sub-layers constituting a solar cell. This measurement is critical for realizing high-efficient ultra-thin solar cells. The screen-printed aluminum layer, which significantly affects the bowing phenomenon, is separated from the complete solar cell by removing the silicon (Si) layer with deep reactive ion etching. An elastic modulus of ~15.1 GPa and a yield strength of ~35.0 MPa for the aluminum (Al) composite layer were obtained by the 3-D LSFM system. In experiments performed for 6-inch Si solar cells, the bowing distances decreased from 12.02 to 1.18 mm while the Si layer thicknesses increased from 90 to 190 μm. These results are in excellent agreement with the theoretical predictions for ultra-thin Si thickness (90 μm) based on the obtained Al composite layer properties. PMID:26948248

  14. Measuring surface topography with scanning electron microscopy. I. EZEImage: a program to obtain 3D surface data.

    PubMed

    Ponz, Ezequiel; Ladaga, Juan Luis; Bonetto, Rita Dominga

    2006-04-01

    Scanning electron microscopy (SEM) is widely used in the science of materials and different parameters were developed to characterize the surface roughness. In a previous work, we studied the surface topography with fractal dimension at low scale and two parameters at high scale by using the variogram, that is, variance vs. step log-log graph, of a SEM image. Those studies were carried out with the FERImage program, previously developed by us. To verify the previously accepted hypothesis by working with only an image, it is indispensable to have reliable three-dimensional (3D) surface data. In this work, a new program (EZEImage) to characterize 3D surface topography in SEM has been developed. It uses fast cross correlation and dynamic programming to obtain reliable dense height maps in a few seconds which can be displayed as an image where each gray level represents a height value. This image can be used for the FERImage program or any other software to obtain surface topography characteristics. EZEImage also generates anaglyph images as well as characterizes 3D surface topography by means of a parameter set to describe amplitude properties and three functional indices for characterizing bearing and fluid properties.

  15. Real-time monitoring of quorum sensing in 3D-printed bacterial aggregates using scanning electrochemical microscopy.

    PubMed

    Connell, Jodi L; Kim, Jiyeon; Shear, Jason B; Bard, Allen J; Whiteley, Marvin

    2014-12-23

    Microbes frequently live in nature as small, densely packed aggregates containing ∼10(1)-10(5) cells. These aggregates not only display distinct phenotypes, including resistance to antibiotics, but also, serve as building blocks for larger biofilm communities. Aggregates within these larger communities display nonrandom spatial organization, and recent evidence indicates that this spatial organization is critical for fitness. Studying single aggregates as well as spatially organized aggregates remains challenging because of the technical difficulties associated with manipulating small populations. Micro-3D printing is a lithographic technique capable of creating aggregates in situ by printing protein-based walls around individual cells or small populations. This 3D-printing strategy can organize bacteria in complex arrangements to investigate how spatial and environmental parameters influence social behaviors. Here, we combined micro-3D printing and scanning electrochemical microscopy (SECM) to probe quorum sensing (QS)-mediated communication in the bacterium Pseudomonas aeruginosa. Our results reveal that QS-dependent behaviors are observed within aggregates as small as 500 cells; however, aggregates larger than 2,000 bacteria are required to stimulate QS in neighboring aggregates positioned 8 μm away. These studies provide a powerful system to analyze the impact of spatial organization and aggregate size on microbial behaviors.

  16. Microscale Diffusion Properties of the Cartilage Pericellular Matrix Measured Using 3D Scanning Microphotolysis

    PubMed Central

    Leddy, Holly A.; Christensen, Susan E.; Guilak, Farshid

    2009-01-01

    Chondrocytes (cartilage cells) are enclosed within a pericellular matrix (PCM) whose composition and structure differ from those of the extracellular matrix (ECM). Since the PCM surrounds each cell, molecules that interact with the chondrocyte must pass through the pericellular environment. A quantitative understanding of the diffusional properties of the PCM will help elucidate the PCM’s regulatory role in controlling transport to and from the chondrocyte. The diffusivity of a fluorescently-labeled 70 kDa dextran was quantified within the PCM of porcine articular cartilage using a newly-developed mathematical model of scanning microphotolysis (SCAMP). SCAMP is a rapid, line photobleaching method that accounts for out-of-plane bleaching attributable to high magnification. Data were analyzed by best-fit comparison to simulations generated using a discretization of the diffusion-reaction equation in conjunction with the microscope-specific three-dimensional excitation and detection profiles. The diffusion coefficient of dextran was significantly lower in the PCM than in the ECM in normal cartilage. In early-stage arthritic tissue, however, no significant differences in diffusivity were detectable. These results support the hypothesis that the diffusivity of the PCM is lower than that of the ECM, presumably due to differences in proteoglycan content, and that osteoarthritic changes in tissue affect the transport properties of the PCM. PMID:19045531

  17. Compact 3D lidar based on optically coupled horizontal and vertical scanning mechanism for the autonomous navigation of robots

    NASA Astrophysics Data System (ADS)

    Lee, Min-Gu; Baeg, Seung-Ho; Lee, Ki-Min; Lee, Hae-Seok; Baeg, Moon-Hong; Park, Jong-Ok; Kim, Hong-Ki

    2011-06-01

    The purpose of this research is to develop a new 3D LIDAR sensor, named KIDAR-B25, for measuring 3D image information with high range accuracy, high speed and compact size. To measure a distance to the target object, we developed a range measurement unit, which is implemented by the direct Time-Of-Flight (TOF) method using TDC chip, a pulsed laser transmitter as an illumination source (pulse width: 10 ns, wavelength: 905 nm, repetition rate: 30kHz, peak power: 20W), and an Si APD receiver, which has high sensitivity and wide bandwidth. Also, we devised a horizontal and vertical scanning mechanism, climbing in a spiral and coupled with the laser optical path. Besides, control electronics such as the motor controller, the signal processing unit, the power distributor and so on, are developed and integrated in a compact assembly. The key point of the 3D LIDAR design proposed in this paper is to use the compact scanning mechanism, which is coupled with optical module horizontally and vertically. This KIDAR-B25 has the same beam propagation axis for emitting pulse laser and receiving reflected one with no optical interference each other. The scanning performance of the KIDAR-B25 has proven with the stable operation up to 20Hz (vertical), 40Hz (horizontal) and the time is about 1.7s to reach the maximum speed. The range of vertical plane can be available up to +/-10 degree FOV (Field Of View) with a 0.25 degree angular resolution. The whole horizontal plane (360 degree) can be also available with 0.125 degree angular resolution. Since the KIDAR-B25 sensor has been planned and developed to be used in mobile robots for navigation, we conducted an outdoor test for evaluating its performance. The experimental results show that the captured 3D imaging data can be usefully applicable to the navigation of the robot for detecting and avoiding the moving objects with real time.

  18. Estimation of regeneration coverage in a temperate forest by 3D segmentation using airborne laser scanning data

    NASA Astrophysics Data System (ADS)

    Amiri, Nina; Yao, Wei; Heurich, Marco; Krzystek, Peter; Skidmore, Andrew K.

    2016-10-01

    Forest understory and regeneration are important factors in sustainable forest management. However, understanding their spatial distribution in multilayered forests requires accurate and continuously updated field data, which are difficult and time-consuming to obtain. Therefore, cost-efficient inventory methods are required, and airborne laser scanning (ALS) is a promising tool for obtaining such information. In this study, we examine a clustering-based 3D segmentation in combination with ALS data for regeneration coverage estimation in a multilayered temperate forest. The core of our method is a two-tiered segmentation of the 3D point clouds into segments associated with regeneration trees. First, small parts of trees (super-voxels) are constructed through mean shift clustering, a nonparametric procedure for finding the local maxima of a density function. In the second step, we form a graph based on the mean shift clusters and merge them into larger segments using the normalized cut algorithm. These segments are used to obtain regeneration coverage of the target plot. Results show that, based on validation data from field inventory and terrestrial laser scanning (TLS), our approach correctly estimates up to 70% of regeneration coverage across the plots with different properties, such as tree height and tree species. The proposed method is negatively impacted by the density of the overstory because of decreasing ground point density. In addition, the estimated coverage has a strong relationship with the overstory tree species composition.

  19. Feasibility of CT-based 3D anatomic mapping with a scanning-beam digital x-ray (SBDX) system

    NASA Astrophysics Data System (ADS)

    Slagowski, Jordan M.; Tomkowiak, Michael T.; Dunkerley, David A. P.; Speidel, Michael A.

    2015-03-01

    This study investigates the feasibility of obtaining CT-derived 3D surfaces from data provided by the scanning-beam digital x-ray (SBDX) system. Simulated SBDX short-scan acquisitions of a Shepp-Logan and a thorax phantom containing a high contrast spherical volume were generated. 3D reconstructions were performed using a penalized weighted least squares method with total variation regularization (PWLS-TV), as well as a more efficient variant employing gridding of projection data to parallel rays (gPWLS-TV). Voxel noise, edge blurring, and surface accuracy were compared to gridded filtered back projection (gFBP). PWLS reconstruction of a noise-free reduced-size Shepp-Logan phantom had 1.4% rRMSE. In noisy gPWLS-TV reconstructions of a reduced-size thorax phantom, 99% of points on the segmented sphere perimeter were within 0.33, 0.47, and 0.70 mm of the ground truth, respectively, for fluences comparable to imaging through 18.0, 27.2, and 34.6 cm acrylic. Surface accuracies of gFBP and gPWLS-TV were similar at high fluences, while gPWLS-TV offered improvement at the lowest fluence. The gPWLS-TV voxel noise was reduced by 60% relative to gFBP, on average. High-contrast linespread functions measured 1.25 mm and 0.96 mm (FWHM) for gPWLS-TV and gFBP. In a simulation of gated and truncated projection data from a full-sized thorax, gPWLS-TV reconstruction yielded segmented surface points which were within 1.41 mm of ground truth. Results support the feasibility of 3D surface segmentation with SBDX. Further investigation of artifacts caused by data truncation and patient motion is warranted.

  20. Final Report – Study of Shortwave Spectra in Fully 3D Environment. Synergy Between Scanning Radars and Spectral Radiation Measurements

    SciTech Connect

    Chiu, Jui-Yuan

    2015-09-14

    ARM set out 20 years ago to “close” the radiation problem, that is, to improve radiation models to the point where they could routinely predict the observed spectral radiation fluxes knowing the optical properties of the surface and of gases, clouds and aerosols in the atmosphere. Only then could such radiation models form a proper springboard for global climate model (GCM) parameterizations of spectral radiation. Sustained efforts have more or less achieved that goal with regard to longwave radiation; ASR models now routinely predict ARM spectral longwave radiances to 1–2%. Similar efforts in the shortwave have achieved far less; the successes are mainly for carefully selected 1D stratiform cloud cases. Such cases amount, even with the most optimistic interpretation, to no more than 30% of all cases at SGP. The problem has not been lack of effort but lack of appropriate instruments.The new ARM stimulus-funded instruments, with their new capabilities, will dramatically improve this situation and once again make progress possible on the shortwave problem. The new shortwave spectrometers will provide a reliable, calibrated record including the near infrared – and for other climatic regimes than SGP. The new scanning radars will provide the 3D cloud view, making it possible to tackle fully 3D situations. Thus, our main theme for the project is the understanding and closure of the surface spectral shortwave radiation problem in fully 3D cloud situations by combining the new ARM scanning radars and shortwave spectrometers with the arsenal of radiative transfer tools.

  1. Feasibility of CT-based 3D anatomic mapping with a scanning-beam digital x-ray (SBDX) system.

    PubMed

    Slagowski, Jordan M; Tomkowiak, Michael T; Dunkerley, David A P; Speidel, Michael A

    This study investigates the feasibility of obtaining CT-derived 3D surfaces from data provided by the scanning-beam digital x-ray (SBDX) system. Simulated SBDX short-scan acquisitions of a Shepp-Logan and a thorax phantom containing a high contrast spherical volume were generated. 3D reconstructions were performed using a penalized weighted least squares method with total variation regularization (PWLS-TV), as well as a more efficient variant employing gridding of projection data to parallel rays (gPWLS-TV). Voxel noise, edge blurring, and surface accuracy were compared to gridded filtered back projection (gFBP). PWLS reconstruction of a noise-free reduced-size Shepp-Logan phantom had 1.4% rRMSE. In noisy gPWLS-TV reconstructions of a reduced-size thorax phantom, 99% of points on the segmented sphere perimeter were within 0.33, 0.47, and 0.70 mm of the ground truth, respectively, for fluences comparable to imaging through 18.0, 27.2, and 34.6 cm acrylic. Surface accuracies of gFBP and gPWLS-TV were similar at high fluences, while gPWLS-TV offered improvement at the lowest fluence. The gPWLS-TV voxel noise was reduced by 60% relative to gFBP, on average. High-contrast linespread functions measured 1.25 mm and 0.96 mm (FWHM) for gPWLS-TV and gFBP. In a simulation of gated and truncated projection data from a full-sized thorax, gPWLS-TV reconstruction yielded segmented surface points which were within 1.41 mm of ground truth. Results support the feasibility of 3D surface segmentation with SBDX. Further investigation of artifacts caused by data truncation and patient motion is warranted.

  2. Optimised 3D surface measurement of hydroxyapatite layers using adapted white light scanning interferometry

    NASA Astrophysics Data System (ADS)

    Pecheva, Emilia; Montgomery, Paul; Montaner, Denis; Pramatarova, Lilyana; Zanev, Zenko

    2006-09-01

    Biomineralization is intensively studied at present due to its importance in the formation of bones, teeth, cartilage, etc. Hydroxyapatite is one of the most common natural biomaterials and the primary structural component of bones and teeth. We have grown bio-like hydroxyapatite layers in-vitro on stainless steel, silicon and silica glass by using a biomimetic approach (immersion in a supersaturated aqueous solution resembling the ion composition of human blood plasma). Using classical techniques such as stylus profiling, AFM or SEM, it was found difficult, destructive or time-consuming to measure the topography, thickness and profile of the heterogeneous, thick and rough hydroxyapatite layers. White light scanning interferometry, on the other hand, has been found to be particularly useful for analyzing such bio-like layers, requiring no sample preparation and being rapid and non-destructive. The results have shown a typical layer thickness of up to 20 μm and a rms roughness of 4 μm. The hydroxyapatite presents nonetheless a challenge for this technique because of its semi-translucence, high roughness and the presence of cavities within its volume. This results in varying qualities of fringe pattern depending on the area, ranging from classical fringes on smooth surfaces, to complex speckle-like fringes on rough surfaces, to multiple fringe signals along the optical axis in the presence of buried layers. In certain configurations this can affect the measurement precision. In this paper we present the latest results for optimizing the measurement conditions in order to reduce such errors and to provide additional useful information concerning the layer.

  3. Documentation and Visualization of AN As-Built Tunnel by Combining 3d Laser Scanning and Web Mapping

    NASA Astrophysics Data System (ADS)

    Zhang, C.; Arditi, D.; Chen, Z.

    2013-08-01

    A new way to document and visualize the as-built condition of an urban tunnel project with high accuracy is described in this paper, based on recent developments of laser scanning technology. In traditional surveying, the components of a tunnel are organized on the basis of the location of stations and offsets along the project alignment specified in the drawings. It is difficult for people without an engineering background to understand the information involved in surveying reports, drawings, and engineering data. However, in the interest of transparency, public agencies that commission construction projects have to make project information available to government officials and to the general public. This paper discusses the combined use of laser scanning technology and web mapping services to improve the documentation and visualization of an urban metro tunnel. Laser scanning technology is introduced to perform the surveyor's task, document the as-built condition, and geo-reference the construction elements. A set of panoramic pictures is generated by laser scanning that allows for taking measurements and extracting 3D coordinates. An XML file that contains geo-reference information is appended to each panoramic picture. Using application programming interface (API), this information is referenced to a web mapping service. A case study of the CTA Red line Tunnel in Chicago, IL demonstrates this method in a real life project.

  4. Terrestrial and Aerial Laser Scanning Data Integration Using Wavelet Analysis for the Purpose of 3D Building Modeling

    PubMed Central

    Kedzierski, Michal; Fryskowska, Anna

    2014-01-01

    Visualization techniques have been greatly developed in the past few years. Three-dimensional models based on satellite and aerial imagery are now being enhanced by models generated using Aerial Laser Scanning (ALS) data. The most modern of such scanning systems have the ability to acquire over 50 points per square meter and to register a multiple echo, which allows the reconstruction of the terrain together with the terrain cover. However, ALS data accuracy is less than 10 cm and the data is often incomplete: there is no information about ground level (in most scanning systems), and often around the facade or structures which have been covered by other structures. However, Terrestrial Laser Scanning (TLS) not only acquires higher accuracy data (1–5 cm) but is also capable of registering those elements which are incomplete or not visible using ALS methods (facades, complicated structures, interiors, etc.). Therefore, to generate a complete 3D model of a building in high Level of Details, integration of TLS and ALS data is necessary. This paper presents the wavelet-based method of processing and integrating data from ALS and TLS. Methods of choosing tie points to combine point clouds in different datum will be analyzed. PMID:25004157

  5. Terrestrial and aerial laser scanning data integration using wavelet analysis for the purpose of 3D building modeling.

    PubMed

    Kedzierski, Michal; Fryskowska, Anna

    2014-07-07

    Visualization techniques have been greatly developed in the past few years. Three-dimensional models based on satellite and aerial imagery are now being enhanced by models generated using Aerial Laser Scanning (ALS) data. The most modern of such scanning systems have the ability to acquire over 50 points per square meter and to register a multiple echo, which allows the reconstruction of the terrain together with the terrain cover. However, ALS data accuracy is less than 10 cm and the data is often incomplete: there is no information about ground level (in most scanning systems), and often around the facade or structures which have been covered by other structures. However, Terrestrial Laser Scanning (TLS) not only acquires higher accuracy data (1-5 cm) but is also capable of registering those elements which are incomplete or not visible using ALS methods (facades, complicated structures, interiors, etc.). Therefore, to generate a complete 3D model of a building in high Level of Details, integration of TLS and ALS data is necessary. This paper presents the wavelet-based method of processing and integrating data from ALS and TLS. Methods of choosing tie points to combine point clouds in different datum will be analyzed.

  6. Automated Breast Volume Scanning: Identifying 3-D Coronal Plane Imaging Features May Help Categorize Complex Cysts.

    PubMed

    Wang, Hong-Yan; Jiang, Yu-Xin; Zhu, Qing-Li; Zhang, Jing; Xiao, Meng-Su; Liu, He; Dai, Qing; Li, Jian-Chu; Sun, Qiang

    2016-03-01

    The study described here sought to identify specific ultrasound (US) automated breast volume scanning (ABVS) features that distinguish benign from malignant lesions. Medical records of 750 patients with 792 breast lesions were retrospectively reviewed. Of the 750 patients, 101 with 122 cystic lesions were included in this study, and the results ABVS results were compared with biopsy pathology results. These lesions were classified into six categories based on ABVS sonographic features: type I = simple cyst; type II = clustered cyst; type III = cystic masses with thin septa; type IV = complex cyst; type V = predominantly cystic masses; and type VI = predominantly solid masses. Comparisons were conducted between the ABVS coronal plane features of the lesions and histopathology results, and the positive predictive value (PPV) was calculated for each feature. Of the 122 lesions, 90 (73.8%) were classified as benign, and 32 (26.2%) were classified as malignant. The sensitivity, specificity and accuracy associated with ABVS features for cystic lesions were 78.1%, 74.4% and 75.4%, respectively. The 11 cases (8.9%) of type I-IV cysts were all benign. Of the 22 (18.0%) type V cysts, 16 (13.1%) were benign and 6 (4.9%) were malignant. Of the 89 (72.9%) type VI cysts, 63 (51.7%) were benign and 26 (21.3%) were malignant. The typical symptoms of malignancy on ABVS include retraction (PPV = 100%, p < 0.05), hyper-echoic halos (PPV = 85.7%, p < 0.05), microcalcification (PPV = 66.7%, p < 0.05), thick walls or thick septa (PPV = 62.5%, p < 0.05), irregular shape (PPV: 51.2%, p < 0.05), indistinct margin (PPV: 48.6%, p < 0.05) and predominantly solid masses with eccentric cystic foci (PPV = 46.8%, p < 0.05). ABVS can reveal sonographic features of the lesions along the coronal plane, which may be of benefit in the detection of malignant, predominantly cystic masses and provide high clinical values.

  7. 3D Printing of Shape Memory Polymers for Flexible Electronic Devices.

    PubMed

    Zarek, Matt; Layani, Michael; Cooperstein, Ido; Sachyani, Ela; Cohn, Daniel; Magdassi, Shlomo

    2016-06-01

    The formation of 3D objects composed of shape memory polymers for flexible electronics is described. Layer-by-layer photopolymerization of methacrylated semicrystalline molten macromonomers by a 3D digital light processing printer enables rapid fabrication of complex objects and imparts shape memory functionality for electrical circuits.

  8. Single-layer microfluidic device to realize hydrodynamic 3D flow focusing.

    PubMed

    Eluru, Gangadhar; Julius, Lourdes Albina Nirupa; Gorthi, Sai Siva

    2016-10-18

    The recent rapid growth of microfluidic applications has witnessed the emergence of several particle flow focusing techniques for analysis and/or further processing. The majority of flow focusing techniques employ an external sheath fluid to achieve sample flow focusing independent of the flow rate, in contrast to sheath-free techniques. However, the introduction of a sheath fluid to surround the sample fluid has complicated the device design and fabrication, generally involving multi-layer fabrication and bonding of multiple polydimethylsiloxane (PDMS) layers. Several promising efforts have been made to reduce the complexity of fabrication. However, most of these methods involved the use of inertial/Dean effects, which in turn demanded the use of higher sample flow rates. In this paper, we report a method of flow focusing that uses a sheath fluid to enclose the sample in a single layer of PDMS, and that possesses applicability for a wide range of sample flow rates. This method of flow focusing uses abrupt channel depth variation and a shift of one of the sample-sheath junctions (termed as 'junction-shift') against the direction of the sample flow. This configuration serves to manipulate the sample fluid with respect to the sheath fluid and achieve the desired flow focusing. This design facilitates the attainment of 3D flow focusing in two sequential steps (depth-wise and then along the lateral direction) and in distinct regions, hence enabling the regions to be used in imaging and non-imaging flow cytometric applications, respectively. Simulations were performed to characterize and determine the optimum set of design parameters. Experimental demonstrations of this technique were carried out by focusing fluorescein dye and blood cells in flow.

  9. Software architecture as a freedom for 3D content providers and users along with independency on purposes and used devices

    NASA Astrophysics Data System (ADS)

    Sultana, Razia; Christ, Andreas; Meyrueis, Patrick

    2014-05-01

    The improvements in the hardware and software of communication devices have allowed running Virtual Reality (VR) and Augmented Reality (AR) applications on those. Nowadays, it is possible to overlay synthetic information on real images, or even to play 3D on-line games on smart phones or some other mobile devices. Hence the use of 3D data for business and specially for education purposes is ubiquitous. Due to always available at hand and always ready to use properties of mobile phones, those are considered as most potential communication devices. The total numbers of mobile phone users are increasing all over the world every day and that makes mobile phones the most suitable device to reach a huge number of end clients either for education or for business purposes. There are different standards, protocols and specifications to establish the communication among different communication devices but there is no initiative taken so far to make it sure that the send data through this communication process will be understood and used by the destination device. Since all the devices are not able to deal with all kind of 3D data formats and it is also not realistic to have different version of the same data to make it compatible with the destination device, it is necessary to have a prevalent solution. The proposed architecture in this paper describes a device and purpose independent 3D data visibility any time anywhere to the right person in suitable format. There is no solution without limitation. The architecture is implemented in a prototype to make an experimental validation of the architecture which also shows the difference between theory and practice.

  10. Optimal invasive key-hole neurosurgery with a miniaturized 3D chip on the tip: Microendoscopic device

    PubMed Central

    Charalampaki, Patra; Igressa, Alhadi; Mahvash, Mehran; Pechlivanis, Ioannis; Schick, Bernhard

    2013-01-01

    Objective: The goal of the performed study was to evaluate the possibility of a three-dimensional endoscope to become a combined microscope-endoscope device in one. We analyzed the ergonomy of the device, the implementation into the surgical workflow, the image quality, and the future perspectives such devices could have for the next generation of neurosurgeons. Materials and Methods: Within 6 months, 22 patients (10 male, 12 female, 20-65 age) underwent surgery in neuroaxis using the new 3D-microendoscope (ME). The new 3D-ME has (a) the ability to visualize the surgical field from out- to inside with all advantages offered by a microscope, and in the same moment, (b) its design is like a small diameter endoscope that allows stereoscopic views extracorporal, intracorporal, and panoramic “para-side” of the lesion. Results: In general, transcranial 3D-“microendoscopy” was performed in all patients with high-resolution 3D quality. No severe complications were observed intra- or postoperatively. With the addition of depth perception, the anatomic structures were well seen and observed. Conclusion: The 3D-microendoscopy is a very promising surgical concept associated with new technological developments. The surgeon is able to switch to a modern visualization instrument reaching the most optimal surgical approach without compromising safety, effectiveness, and visual information. PMID:24403954

  11. Design and evaluation of an MRI compatible axial compression device for 3D assessment of spinal deformity and flexibility in AIS.

    PubMed

    Adam, Clayton; Izatt, Maree; Askin, Geoffrey

    2010-01-01

    Magnetic Resonance Imaging (MRI) offers a valuable research tool for the assessment of 3D spinal deformity in AIS, however the horizontal patient position imposed by conventional scanners removes the axial compressive loading on the spine. The objective of this study was to design, construct and test an MRI compatible compression device for research into the effect of axial loading on spinal deformity using supine MRI scans. The device was evaluated by performing unloaded and loaded supine MRI scans on a series of 10 AIS patients. The patient group had a mean initial (unloaded) major Cobb angle of 43+/-7 degrees, which increased to 50+/-9 degrees on application of the compressive load. The 7 degrees increase in mean Cobb angle is consistent with that reported by a previous study comparing standing versus supine posture in scoliosis patients (Torell et al, 1985. Spine 10:425-7).

  12. Terrestrial laser scanning point clouds time series for the monitoring of slope movements: displacement measurement using image correlation and 3D feature tracking

    NASA Astrophysics Data System (ADS)

    Bornemann, Pierrick; Jean-Philippe, Malet; André, Stumpf; Anne, Puissant; Julien, Travelletti

    2016-04-01

    Dense multi-temporal point clouds acquired with terrestrial laser scanning (TLS) have proved useful for the study of structure and kinematics of slope movements. Most of the existing deformation analysis methods rely on the use of interpolated data. Approaches that use multiscale image correlation provide a precise and robust estimation of the observed movements; however, for non-rigid motion patterns, these methods tend to underestimate all the components of the movement. Further, for rugged surface topography, interpolated data introduce a bias and a loss of information in some local places where the point cloud information is not sufficiently dense. Those limits can be overcome by using deformation analysis exploiting directly the original 3D point clouds assuming some hypotheses on the deformation (e.g. the classic ICP algorithm requires an initial guess by the user of the expected displacement patterns). The objective of this work is therefore to propose a deformation analysis method applied to a series of 20 3D point clouds covering the period October 2007 - October 2015 at the Super-Sauze landslide (South East French Alps). The dense point clouds have been acquired with a terrestrial long-range Optech ILRIS-3D laser scanning device from the same base station. The time series are analyzed using two approaches: 1) a method of correlation of gradient images, and 2) a method of feature tracking in the raw 3D point clouds. The estimated surface displacements are then compared with GNSS surveys on reference targets. Preliminary results tend to show that the image correlation method provides a good estimation of the displacement fields at first order, but shows limitations such as the inability to track some deformation patterns, and the use of a perspective projection that does not maintain original angles and distances in the correlated images. Results obtained with 3D point clouds comparison algorithms (C2C, ICP, M3C2) bring additional information on the

  13. Non-invasive transcranial ultrasound therapy based on a 3D CT scan: protocol validation and in vitro results

    NASA Astrophysics Data System (ADS)

    Marquet, F.; Pernot, M.; Aubry, J.-F.; Montaldo, G.; Marsac, L.; Tanter, M.; Fink, M.

    2009-05-01

    A non-invasive protocol for transcranial brain tissue ablation with ultrasound is studied and validated in vitro. The skull induces strong aberrations both in phase and in amplitude, resulting in a severe degradation of the beam shape. Adaptive corrections of the distortions induced by the skull bone are performed using a previous 3D computational tomography scan acquisition (CT) of the skull bone structure. These CT scan data are used as entry parameters in a FDTD (finite differences time domain) simulation of the full wave propagation equation. A numerical computation is used to deduce the impulse response relating the targeted location and the ultrasound therapeutic array, thus providing a virtual time-reversal mirror. This impulse response is then time-reversed and transmitted experimentally by a therapeutic array positioned exactly in the same referential frame as the one used during CT scan acquisitions. In vitro experiments are conducted on monkey and human skull specimens using an array of 300 transmit elements working at a central frequency of 1 MHz. These experiments show a precise refocusing of the ultrasonic beam at the targeted location with a positioning error lower than 0.7 mm. The complete validation of this transcranial adaptive focusing procedure paves the way to in vivo animal and human transcranial HIFU investigations.

  14. Quasi-3D Modeling and Efficient Simulation of Laminar Flows in Microfluidic Devices.

    PubMed

    Islam, Md Zahurul; Tsui, Ying Yin

    2016-10-03

    A quasi-3D model has been developed to simulate the flow in planar microfluidic systems with low Reynolds numbers. The model was developed by decomposing the flow profile along the height of a microfluidic system into a Fourier series. It was validated against the analytical solution for flow in a straight rectangular channel and the full 3D numerical COMSOL Navier-Stokes solver for flow in a T-channel. Comparable accuracy to the full 3D numerical solution was achieved by using only three Fourier terms with a significant decrease in computation time. The quasi-3D model was used to model flows in a micro-flow cytometer chip on a desktop computer and good agreement between the simulation and the experimental results was found.

  15. Quasi-3D Modeling and Efficient Simulation of Laminar Flows in Microfluidic Devices

    PubMed Central

    Islam, Md. Zahurul; Tsui, Ying Yin

    2016-01-01

    A quasi-3D model has been developed to simulate the flow in planar microfluidic systems with low Reynolds numbers. The model was developed by decomposing the flow profile along the height of a microfluidic system into a Fourier series. It was validated against the analytical solution for flow in a straight rectangular channel and the full 3D numerical COMSOL Navier-Stokes solver for flow in a T-channel. Comparable accuracy to the full 3D numerical solution was achieved by using only three Fourier terms with a significant decrease in computation time. The quasi-3D model was used to model flows in a micro-flow cytometer chip on a desktop computer and good agreement between the simulation and the experimental results was found. PMID:27706104

  16. Interventional left atrial appendage occlusion: added value of 3D transesophageal echocardiography for device sizing.

    PubMed

    Goebel, Björn; Wieg, Stephanie; Hamadanchi, Ali; Otto, Sylvia; Jung, Christian; Kretzschmar, Daniel; Figulla, Hans R; Christian Schulze, P; Poerner, Tudor C

    2016-09-01

    Aim of this study was the assessment of left atrial appendage (LAA) dimensions comparing 2D- to 3D-TEE measurements in patients with nonvalvular atrial fibrillation undergoing percutaneous LAA occlusion. Patients underwent transesophageal echocardiography (TEE) before, during and 45 days after intervention. The maximal LAA orifice diameters in 2D-TEE (LODmax 2D) were obtained from multiple views. Test-retest reliability (screening vs. implantation), inter- and intra-observer variability for echocardiographic parameters were assessed by two independent examiners. Overall, 74 patients underwent percutaneous LAA occlusion. 2D-TEE significantly underestimated the maximal LAA orifice diameter compared with 3D-TEE (screening LODmax 2D 21.11 ± 2.75 mm vs. 22.52 ± 3.45 mm for LODmax 3D, p < 0.001; during implantation LODmax 2D 21.56 ± 3.48 mm vs. 22.99 ± 3.24 mm for LODmax 3D, p < 0.001). The intraobserver and interobserver variability calculated as coefficient of variation (CV) were both lower for the 3D-TEE quantification of the maximal orifice diameter (intraobserver CV for 3D-TEE 6.07 % vs. 9.31 % for 2D-TEE; interobserver CV for 3D-TEE 6.73 % vs. 9.69 % for 2D-TEE). Compared to 3D-TEE the test-retest reliability of 2D-TEE showed a lower intraclass correlation coefficient calculated as average of raters (0.92 for 3D-TEE vs. for 2D-TEE 0.78). Firstly, 2D-TEE significantly underestimates the maximal LAA orifice diameter compared to 3D-TEE. Secondly, 3D-TEE measurements are associated with a lower observer variability and higher reliability than 2D-TEE.

  17. Light-driven 3D droplet manipulation on flexible optoelectrowetting devices fabricated by a simple spin-coating method.

    PubMed

    Jiang, Dongyue; Park, Sung-Yong

    2016-05-21

    Technical advances in electrowetting-on-dielectric (EWOD) over the past few years have extended our attraction to three-dimensional (3D) devices capable of providing more flexibility and functionality with larger volumetric capacity than conventional 2D planar ones. However, typical 3D EWOD devices require complex and expensive fabrication processes for patterning and wiring of pixelated electrodes that also restrict the minimum droplet size to be manipulated. Here, we present a flexible single-sided continuous optoelectrowetting (SCOEW) device which is not only fabricated by a spin-coating method without the need for patterning and wiring processes, but also enables light-driven 3D droplet manipulations. To provide photoconductive properties, previous optoelectrowetting (OEW) devices have used amorphous silicon (a-Si) typically fabricated through high-temperature processes over 300 °C such as CVD or PECVD. However, most of the commercially-available flexible substrates such as polyethylene terephthalate (PET) and polyethylene naphthalate (PEN) experience serious thermal deformation under such high-temperature processes. Because of this compatibility issue of conventional OEW devices with flexible substrates, light-driven 3D droplet manipulations have not yet been demonstrated on flexible substrates. Our study overcomes this compatibility issue by using a polymer-based photoconductive material, titanium oxide phthalocyanine (TiOPc) and thus SCOEW devices can be simply fabricated on flexible substrates through a low-cost, spin-coating method. In this paper, analytical studies were conducted to understand the effects of light patterns on static contact angles and EWOD forces. For experimental validations of our study, flexible SCOEW devices were successfully fabricated through the TiOPc-based spin-coating method and light-driven droplet manipulations (e.g. transportation, merging, and splitting) have been demonstrated on various 3D terrains such as inclined

  18. Physics-based Simulation of Human Posture Using 3D Whole Body Scanning Technology for Astronaut Space Suit Evaluation

    NASA Technical Reports Server (NTRS)

    Kim, Kyu-Jung

    2005-01-01

    Over the past few years high precision three-dimensional (3D) full body laser scanners have been developed to be used as a powerful anthropometry tool for quantification of the morphology of the human body. The full body scanner can quickly extract body characteristics in non-contact fashion. It is required for the Anthropometry and Biomechanics Facility (ABF) to have capabilities for kinematics simulation of a digital human at various postures whereas the laser scanner only allows capturing a single static posture at each time. During this summer fellowship period a theoretical study has been conducted to estimate an arbitrary posture with a series of example postures through finite element (FE) approximation and found that four-point isoparametric FE approximation would result in reasonable maximum position errors less than 5%. Subsequent pilot scan experiments demonstrated that a bead marker with a nominal size of 6 mm could be used as a marker for digitizing 3-D coordinates of anatomical landmarks for further kinematic analysis. Two sessions of human subject testing were conducted for reconstruction of an arbitrary postures from a set of example postures for each joint motion for the forearm/hand complex and the whole upper extremity.

  19. A New Display Format Relating Azimuth-Scanning Radar Data and All-Sky Images in 3-D

    NASA Technical Reports Server (NTRS)

    Swartz, Wesley E.; Seker, Ilgin; Mathews, John D.; Aponte, Nestor

    2010-01-01

    Here we correlate features in a sequence of all-sky images of 630 nm airglow with the three-dimensional (3-D) structure of electron densities in the F region above Arecibo. Pairs of 180 azimuth scans (using the Gregorian and line feeds) of the two-beam incoherent scatter radar (ISR) have been plotted in cone pictorials of the line-of-sight electron densities. The plots include projections of the 630 nm airglow onto the ground using the same spatial scaling as for the ISR data. Selected sequential images from the night of 16-17 June 2004 correlate ionospheric plasma features with scales comparable to the ISR density-cone diameter. The entire set of over 100 images spanning about eight hours is available as a movie. The correlation between the airglow and the electron densities is not unexpected, but the new display format shows the 3-D structures better than separate 2-D plots in latitude and longitude for the airglow and in height and time for the electron densities. Furthermore, the animations help separate the bands of airglow from obscuring clouds and the star field.

  20. Fast and memory-efficient LOGISMOS graph search for intraretinal layer segmentation of 3D macular OCT scans

    NASA Astrophysics Data System (ADS)

    Lee, Kyungmoo; Zhang, Li; Abramoff, Michael D.; Sonka, Milan

    2015-03-01

    Image segmentation is important for quantitative analysis of medical image data. Recently, our research group has introduced a 3-D graph search method which can simultaneously segment optimal interacting surfaces with respect to the cost function in volumetric images. Although it provides excellent segmentation accuracy, it is computationally demanding (both CPU and memory) to simultaneously segment multiple surfaces from large volumetric images. Therefore, we propose a new, fast, and memory-efficient graph search method for intraretinal layer segmentation of 3-D macular optical coherence tomograpy (OCT) scans. The key idea is to reduce the size of a graph by combining the nodes with high costs based on the multiscale approach. The new approach requires significantly less memory and achieves significantly faster processing speeds (p < 0.01) with only small segmentation differences compared to the original graph search method. This paper discusses sub-optimality of this approach and assesses trade-off relationships between decreasing processing speed and increasing segmentation differences from that of the original method as a function of employed scale of the underlying graph construction.

  1. A three-stage method for the 3D reconstruction of the tracheobronchial tree from CT scans.

    PubMed

    Rosell, Jan; Cabras, Paolo

    2013-01-01

    This paper proposes a method for segmenting the airways from CT scans of the chest to obtain a 3D model that can be used in the virtual bronchoscopy for the exploration and the planning of paths to the lesions. The method is composed of 3 stages: a gross segmentation that reconstructs the main airway tree using adaptive region growing, a finer segmentation that identifies any potential airway region based on a 2D process that enhances bronchi walls using local information, and a final process to connect any isolated bronchus to the main airways using a morphologic reconstruction process and a path planning technique. The paper includes two examples for the evaluation and discussion of the proposal.

  2. 3D Scan of Ornamental Column (huabiao) Using Terrestrial LiDAR and Hand-held Imager

    NASA Astrophysics Data System (ADS)

    Zhang, W.; Wang, C.; Xi, X.

    2015-08-01

    In ancient China, Huabiao was a type of ornamental column used to decorate important buildings. We carried out 3D scan of a Huabiao located in Peking University, China. This Huabiao was built no later than 1742. It is carved by white marble, 8 meters in height. Clouds and various postures of dragons are carved on its body. Two instruments were used to acquire the point cloud of this Huabiao, a terrestrial LiDAR (Riegl VZ-1000) and a hand-held imager (Mantis Vision F5). In this paper, the details of the experiment were described, including the differences between these two instruments, such as working principle, spatial resolution, accuracy, instrument dimension and working flow. The point clouds obtained respectively by these two instruments were compared, and the registered point cloud of Huabiao was also presented. These should be of interest and helpful for the research communities of archaeology and heritage.

  3. Lansce Wire Scanning Diagnostics Device Mechanical Design

    SciTech Connect

    Rodriguez Esparza, Sergio; Batygin, Yuri K.; Gilpatrick, John D.; Gruchalla, Michael E.; Maestas, Alfred J.; Pillai, Chandra; Raybun, Joseph L.; Sattler, F. D.; Sedillo, James Daniel; Smith, Brian G.

    2011-01-01

    The Accelerator Operations & Technology Division at Los Alamos National Laboratory operates a linear particle accelerator which utilizes 110 wire scanning diagnostics devices to gain position and intensity information of the proton beam. In the upcoming LANSCE improvements, 51 of these wire scanners are to be replaced with a new design, up-to-date technology and off-the-shelf components. This document outlines the requirements for the mechanical design of the LANSCE wire scanner and presents the recently developed linac wire scanner prototype. Additionally, this document presents the design modifications that have been implemented into the fabrication and assembly of this first linac wire scanner prototype. Also, this document will present the design for the second, third, and fourth wire scanner prototypes being developed. Prototypes 2 and 3 belong to a different section of the particle accelerator and therefore have slightly different design specifications. Prototype 4 is a modification of a previously used wire scanner in our facility. Lastly, the paper concludes with a plan for future work on the wire scanner development.

  4. Graphics to H.264 video encoding for 3D scene representation and interaction on mobile devices using region of interest

    NASA Astrophysics Data System (ADS)

    Le, Minh Tuan; Nguyen, Congdu; Yoon, Dae-Il; Jung, Eun Ku; Jia, Jie; Kim, Hae-Kwang

    2007-12-01

    In this paper, we propose a method of 3D graphics to video encoding and streaming that are embedded into a remote interactive 3D visualization system for rapidly representing a 3D scene on mobile devices without having to download it from the server. In particular, a 3D graphics to video framework is presented that increases the visual quality of regions of interest (ROI) of the video by performing more bit allocation to ROI during H.264 video encoding. The ROI are identified by projection 3D objects to a 2D plane during rasterization. The system offers users to navigate the 3D scene and interact with objects of interests for querying their descriptions. We developed an adaptive media streaming server that can provide an adaptive video stream in term of object-based quality to the client according to the user's preferences and the variation of network bandwidth. Results show that by doing ROI mode selection, PSNR of test sample slightly change while visual quality of objects increases evidently.

  5. One-Step Fabrication of a Microfluidic Device with an Integrated Membrane and Embedded Reagents by Multimaterial 3D Printing.

    PubMed

    Li, Feng; Smejkal, Petr; Macdonald, Niall P; Guijt, Rosanne M; Breadmore, Michael C

    2017-04-05

    One of the largest impediments in the development of microfluidic-based smart sensing systems is the manufacturability of integrated, complex devices. Here we propose multimaterial 3D printing for the fabrication of such devices in a single step. A microfluidic device containing an integrated porous membrane and embedded liquid reagents was made by 3D printing and applied for the analysis of nitrate in soil. The manufacture of the integrated, sealed device was realized as a single print within 30 min. The body of the device was printed in transparent acrylonitrile butadiene styrene (ABS) and contained a 400 μm wide structure printed from a commercially available composite filament. The composite filament can be turned into a porous material through dissolution of a water-soluble material. Liquid reagents were integrated by briefly pausing the printing before resuming for sealing the device. The devices were evaluated by the determination of nitrate in a soil slurry containing zinc particles for the reduction of nitrate to nitrite using the Griess reagent. Using a consumer digital camera, the linear range of the detector response ranged from 0 to 60 ppm, covering the normal range of nitrate in soil. To ensure that the sealing of the reagent chamber is maintained, aqueous reagents should be avoided. When using the nonaqueous reagent, the multimaterial device containing the Griess reagent could be stored for over 4 days but increased the detection range to 100-500 ppm. Multimaterial 3D printing is a potentially new approach for the manufacture of microfluidic devices with multiple integrated functional components.

  6. Volumetric LiDAR scanning of a wind turbine wake and comparison with a 3D analytical wake model

    NASA Astrophysics Data System (ADS)

    Carbajo Fuertes, Fernando; Porté-Agel, Fernando

    2016-04-01

    A correct estimation of the future power production is of capital importance whenever the feasibility of a future wind farm is being studied. This power estimation relies mostly on three aspects: (1) a reliable measurement of the wind resource in the area, (2) a well-established power curve of the future wind turbines and, (3) an accurate characterization of the wake effects; the latter being arguably the most challenging one due to the complexity of the phenomenon and the lack of extensive full-scale data sets that could be used to validate analytical or numerical models. The current project addresses the problem of obtaining a volumetric description of a full-scale wake of a 2MW wind turbine in terms of velocity deficit and turbulence intensity using three scanning wind LiDARs and two sonic anemometers. The characterization of the upstream flow conditions is done by one scanning LiDAR and two sonic anemometers, which have been used to calculate incoming vertical profiles of horizontal wind speed, wind direction and an approximation to turbulence intensity, as well as the thermal stability of the atmospheric boundary layer. The characterization of the wake is done by two scanning LiDARs working simultaneously and pointing downstream from the base of the wind turbine. The direct LiDAR measurements in terms of radial wind speed can be corrected using the upstream conditions in order to provide good estimations of the horizontal wind speed at any point downstream of the wind turbine. All this data combined allow for the volumetric reconstruction of the wake in terms of velocity deficit as well as turbulence intensity. Finally, the predictions of a 3D analytical model [1] are compared to the 3D LiDAR measurements of the wind turbine. The model is derived by applying the laws of conservation of mass and momentum and assuming a Gaussian distribution for the velocity deficit in the wake. This model has already been validated using high resolution wind-tunnel measurements

  7. 3D Visualization of Cultural Heritage Artefacts with Virtual Reality devices

    NASA Astrophysics Data System (ADS)

    Gonizzi Barsanti, S.; Caruso, G.; Micoli, L. L.; Covarrubias Rodriguez, M.; Guidi, G.

    2015-08-01

    Although 3D models are useful to preserve the information about historical artefacts, the potential of these digital contents are not fully accomplished until they are not used to interactively communicate their significance to non-specialists. Starting from this consideration, a new way to provide museum visitors with more information was investigated. The research is aimed at valorising and making more accessible the Egyptian funeral objects exhibited in the Sforza Castle in Milan. The results of the research will be used for the renewal of the current exhibition, at the Archaeological Museum in Milan, by making it more attractive. A 3D virtual interactive scenario regarding the "path of the dead", an important ritual in ancient Egypt, was realized to augment the experience and the comprehension of the public through interactivity. Four important artefacts were considered for this scope: two ushabty, a wooden sarcophagus and a heart scarab. The scenario was realized by integrating low-cost Virtual Reality technologies, as the Oculus Rift DK2 and the Leap Motion controller, and implementing a specific software by using Unity. The 3D models were implemented by adding responsive points of interest in relation to important symbols or features of the artefact. This allows highlighting single parts of the artefact in order to better identify the hieroglyphs and provide their translation. The paper describes the process for optimizing the 3D models, the implementation of the interactive scenario and the results of some test that have been carried out in the lab.

  8. A medical application integrating remote 3D visualization tools to access picture archiving and communication system on mobile devices.

    PubMed

    He, Longjun; Ming, Xing; Liu, Qian

    2014-04-01

    With computing capability and display size growing, the mobile device has been used as a tool to help clinicians view patient information and medical images anywhere and anytime. However, for direct interactive 3D visualization, which plays an important role in radiological diagnosis, the mobile device cannot provide a satisfactory quality of experience for radiologists. This paper developed a medical system that can get medical images from the picture archiving and communication system on the mobile device over the wireless network. In the proposed application, the mobile device got patient information and medical images through a proxy server connecting to the PACS server. Meanwhile, the proxy server integrated a range of 3D visualization techniques, including maximum intensity projection, multi-planar reconstruction and direct volume rendering, to providing shape, brightness, depth and location information generated from the original sectional images for radiologists. Furthermore, an algorithm that changes remote render parameters automatically to adapt to the network status was employed to improve the quality of experience. Finally, performance issues regarding the remote 3D visualization of the medical images over the wireless network of the proposed application were also discussed. The results demonstrated that this proposed medical application could provide a smooth interactive experience in the WLAN and 3G networks.

  9. Custom fabrication of biomass containment devices using 3-D printing enables bacterial growth analyses with complex insoluble substrates

    SciTech Connect

    Nelson, Cassandra E.; Beri, Nina R.; Gardner, Jeffrey G.

    2016-09-21

    Physiological studies of recalcitrant polysaccharide degradation are challenging for several reasons, one of which is the difficulty in obtaining a reproducibly accurate real-time measurement of bacterial growth using insoluble substrates. Current methods suffer from several problems including (i) high background noise due to the insoluble material interspersed with cells, (ii) high consumable and reagent cost and (iii) significant time delay between sampling and data acquisition. A customizable substrate and cell separation device would provide an option to study bacterial growth using optical density measurements. To test this hypothesis we used 3-D printing to create biomass containment devices that allow interaction between insoluble substrates and microbial cells but do not interfere with spectrophotometer measurements. Evaluation of materials available for 3-D printing indicated that UV-cured acrylic plastic was the best material, being superior to nylon or stainless steel when examined for heat tolerance, reactivity, and ability to be sterilized. Cost analysis of the 3-D printed devices indicated they are a competitive way to quantitate bacterial growth compared to viable cell counting or protein measurements, and experimental conditions were scalable over a 100-fold range. The presence of the devices did not alter growth phenotypes when using either soluble substrates or insoluble substrates. Furthermore, we applied biomass containment to characterize growth of Cellvibrio japonicus on authentic lignocellulose (non-pretreated corn stover), and found physiological evidence that xylan is a significant nutritional source despite an abundance of cellulose present.

  10. Custom fabrication of biomass containment devices using 3-D printing enables bacterial growth analyses with complex insoluble substrates

    DOE PAGES

    Nelson, Cassandra E.; Beri, Nina R.; Gardner, Jeffrey G.

    2016-09-21

    Physiological studies of recalcitrant polysaccharide degradation are challenging for several reasons, one of which is the difficulty in obtaining a reproducibly accurate real-time measurement of bacterial growth using insoluble substrates. Current methods suffer from several problems including (i) high background noise due to the insoluble material interspersed with cells, (ii) high consumable and reagent cost and (iii) significant time delay between sampling and data acquisition. A customizable substrate and cell separation device would provide an option to study bacterial growth using optical density measurements. To test this hypothesis we used 3-D printing to create biomass containment devices that allow interactionmore » between insoluble substrates and microbial cells but do not interfere with spectrophotometer measurements. Evaluation of materials available for 3-D printing indicated that UV-cured acrylic plastic was the best material, being superior to nylon or stainless steel when examined for heat tolerance, reactivity, and ability to be sterilized. Cost analysis of the 3-D printed devices indicated they are a competitive way to quantitate bacterial growth compared to viable cell counting or protein measurements, and experimental conditions were scalable over a 100-fold range. The presence of the devices did not alter growth phenotypes when using either soluble substrates or insoluble substrates. Furthermore, we applied biomass containment to characterize growth of Cellvibrio japonicus on authentic lignocellulose (non-pretreated corn stover), and found physiological evidence that xylan is a significant nutritional source despite an abundance of cellulose present.« less

  11. Technical Note: Immunohistochemical evaluation of mouse brain irradiation targeting accuracy with 3D-printed immobilization device

    SciTech Connect

    Zarghami, Niloufar Jensen, Michael D.; Talluri, Srikanth; Dick, Frederick A.; Foster, Paula J.; Chambers, Ann F.; Wong, Eugene

    2015-11-15

    Purpose: Small animal immobilization devices facilitate positioning of animals for reproducible imaging and accurate focal radiation therapy. In this study, the authors demonstrate the use of three-dimensional (3D) printing technology to fabricate a custom-designed mouse head restraint. The authors evaluate the accuracy of this device for the purpose of mouse brain irradiation. Methods: A mouse head holder was designed for a microCT couch using CAD software and printed in an acrylic based material. Ten mice received half-brain radiation while positioned in the 3D-printed head holder. Animal placement was achieved using on-board image guidance and computerized asymmetric collimators. To evaluate the precision of beam localization for half-brain irradiation, mice were sacrificed approximately 30 min after treatment and brain sections were stained for γ-H2AX, a marker for DNA breaks. The distance and angle of the γ-H2AX radiation beam border to longitudinal fissure were measured on histological samples. Animals were monitored for any possible trauma from the device. Results: Visualization of the radiation beam on ex vivo brain sections with γ-H2AX immunohistochemical staining showed a sharp radiation field within the tissue. Measurements showed a mean irradiation targeting error of 0.14 ± 0.09 mm (standard deviation). Rotation between the beam axis and mouse head was 1.2° ± 1.0° (standard deviation). The immobilization device was easily adjusted to accommodate different sizes of mice. No signs of trauma to the mice were observed from the use of tooth block and ear bars. Conclusions: The authors designed and built a novel 3D-printed mouse head holder with many desired features for accurate and reproducible radiation targeting. The 3D printing technology was found to be practical and economical for producing a small animal imaging and radiation restraint device and allows for customization for study specific needs.

  12. Fabrication of a three dimensional particle focusing microfluidic device using a 3D printer, PDMS, and glass

    NASA Astrophysics Data System (ADS)

    Collette, Robyn; Rosen, Daniel; Shirk, Kathryn

    Microfluidic devices have high importance in fields such as bioanalysis because they can manipulate volumes of fluid in the range of microliters to picoliters. Small samples can be quickly and easily tested using complex microfluidic devices. Typically, these devices are created through lithography techniques, which can be costly and time consuming. It has been shown that inexpensive microfluidic devices can be produced quickly using a 3D printer and PDMS. However, a size limitation prohibits the fabrication of precisely controlled microchannels. By using shrinking materials in combination with 3D printing of flow-focusing geometries, this limitation can be overcome. This research seeks to employ these techniques to quickly fabricate an inexpensive, working device with three dimensional particle focusing capabilities. By modifying the channel geometry, colloidal particles in a solution will be focused into a single beam when passed through this device. The ability to focus particles is necessary for a variety of biological applications which requires precise detection and characterization of particles in a sample. We would like to thank the Shippensburg University Undergraduate Research Grant Program for their generous funding.

  13. Charged particle imaging methods for CD metrology of sub 22nm 3D device structures

    NASA Astrophysics Data System (ADS)

    Cepler, Aron

    Critical dimension scanning electron microscopes (CD-SEMs) are used to perform highly accurate dimensional metrology on patterned features. In order to ensure optimal feedback for process control, it is necessary that these tools produce highly reproducible measurements. As the smallest device features continue to shrink, and new challenging high aspect ratio (HAR) structures are being introduced, gaps are appearing between process control measurements that are necessary for high volume manufacturing and the capabilities of the CD-SEM. Two possible routes for solving this problem include improvement of the existing CD-SEM technology or the replacement of the CD-SEM. With improved tool monitoring techniques, the uncertainty in the tool measurements may be reduced, leading to an improvement in the tool performance. By using a carefully designed test structure (such as a pseudorandom dot array), the Contrast Transfer Function (CTF) of a given tool can be decoupled from the specimen information, allowing for characterization of the imaging system itself. Test samples are fabricated using nanoimprint lithography and are imaged in a variety of CD-SEMs in order to measure the performance of the microscopes. This technique is used successfully to identify when the tool is not performing optimally, as well as to monitor the performance of a tool over time and match the performance of different tools. Research is being made into CD-SEM replacement technologies, among them, ion microscopy. The Helium Ion Microscope's (HeIM) higher depth of focus than the CD-SEM could be advantageous for the imaging of HAR structures. Studies were conducted in order to determine what imaging signals will be the most useful for CD-metrology and to evaluate the damage that the beam will do to the sample. A technique was developed to determine the depth which that signals were able to escape from the HAR structures, using a series of images acquired with varied tilts. This allows the abilities of

  14. Improving sample distribution homogeneity in Three-Dimensional Microfluidic Paper-Based Analytical Devices (3D-μPAD) by rational device design.

    PubMed

    Morbioli, Giorgio Gianini; Mazzu-Nascimento, Thiago; Milan, Luis Aparecido; Stockton, Amanda M; Carrilho, Emanuel

    2017-04-12

    Paper-based devices are a portable, user-friendly and affordable technology that is one of the best analytical tools for inexpensive diagnostic devices. Three-dimensional microfluidic paper-based analytical devices (3D-μPADs) are an evolution of single layer devices and they permit effective sample dispersion, individual layer treatment, and multiplex analytical assays. Here, we present the rational design of a wax-printed 3D-μPAD that enables more homogeneous permeation of fluids along the cellulose matrix than other existing designs in the literature. Moreover, we show the importance of the rational design of channels on these devices using glucose oxidase, peroxidase, and 2,2'-azino-bis(3-ethylbenzothiazoline-6-sulphonic acid) (ABTS) reactions. We present an alternative method for layer stacking using a magnetic apparatus, which facilitates fluidic dispersion and improves the reproducibility of tests performed on 3D-μPADs. We also provide the optimized designs for printing, facilitating further studies using 3D-μPADs.

  15. 3D interactive augmented reality-enhanced digital learning systems for mobile devices

    NASA Astrophysics Data System (ADS)

    Feng, Kai-Ten; Tseng, Po-Hsuan; Chiu, Pei-Shuan; Yang, Jia-Lin; Chiu, Chun-Jie

    2013-03-01

    With enhanced processing capability of mobile platforms, augmented reality (AR) has been considered a promising technology for achieving enhanced user experiences (UX). Augmented reality is to impose virtual information, e.g., videos and images, onto a live-view digital display. UX on real-world environment via the display can be e ectively enhanced with the adoption of interactive AR technology. Enhancement on UX can be bene cial for digital learning systems. There are existing research works based on AR targeting for the design of e-learning systems. However, none of these work focuses on providing three-dimensional (3-D) object modeling for en- hanced UX based on interactive AR techniques. In this paper, the 3-D interactive augmented reality-enhanced learning (IARL) systems will be proposed to provide enhanced UX for digital learning. The proposed IARL systems consist of two major components, including the markerless pattern recognition (MPR) for 3-D models and velocity-based object tracking (VOT) algorithms. Realistic implementation of proposed IARL system is conducted on Android-based mobile platforms. UX on digital learning can be greatly improved with the adoption of proposed IARL systems.

  16. Wide-viewing-angle 3D/2D convertible display system using two display devices and a lens array.

    PubMed

    Choi, Heejin; Park, Jae-Hyeung; Kim, Joohwan; Cho, Seong-Woo; Lee, Byoungho

    2005-10-17

    A wide-viewing-angle 3D/2D convertible display system with a thin structure is proposed that is able to display three-dimensional and two-dimensional images. With the use of a transparent display device in front of a conventional integral imaging system, it is possible to display planar images using the conventional system as a backlight source. By experiments, the proposed method is proven and compared with the conventional one.

  17. Soft tissue-preserving computer-aided impression: a novel concept using ultrasonic 3D-scanning.

    PubMed

    Vollborn, Thorsten; Habor, Daniel; Pekam, Fabrice Chuembou; Heger, Stefan; Marotti, Juliana; Reich, Sven; Wolfart, Stefan; Tinschert, Joachim; Radermacher, Klaus

    2014-01-01

    Subgingival preparations are often affected by blood and saliva during impression taking, regardless of whether one is using compound impression techniques or intraoral digital scanning methods. The latter are currently based on optical principles and therefore also need clean and dry surfaces. In contrast, ultrasonic waves are able to non-invasively penetrate gingiva, saliva, and blood, leading to decisive advantages, as cleaning and drying of the oral cavity becomes unnecessary. In addition, the application of ultrasound may facilitate the detection of subgingival structures without invasive manipulation, thereby reducing the risk of secondary infection and treatment time, and increasing patient comfort. Ultrasound devices commonly available for medical application and for the testing of materials are only suitable to a limited extent, as their resolution, precision, and design do not fulfill the requirements for intraoral scanning. The aim of this article is to describe the development of a novel ultrasound technology that enables soft tissue-preserving digital impressions of preparations for the CAD/CAM-based production of dental prostheses. The concept and development of the high-resolution ultrasound technique and the corresponding intraoral scanning system, as well as the integration into the CAD/CAM process chain, is presented.

  18. Impact of continuing scaling on the device performance of 3D cylindrical junction-less charge trapping memory

    NASA Astrophysics Data System (ADS)

    Xinkai, Li; Zongliang, Huo; Lei, Jin; Dandan, Jiang; Peizhen, Hong; Qiang, Xu; Zhaoyun, Tang; Chunlong, Li; Tianchun, Ye

    2015-09-01

    This work presents a comprehensive analysis of 3D cylindrical junction-less charge trapping memory device performance regarding continuous scaling of the structure dimensions. The key device performance, such as program/erase speed, vertical charge loss, and lateral charge migration under high temperature are intensively studied using the Sentaurus 3D device simulator. Although scaling of channel radius is beneficial for operation speed improvement, it leads to a retention challenge due to vertical leakage, especially enhanced charge loss through TPO. Scaling of gate length not only decreases the program/erase speed but also leads to worse lateral charge migration. Scaling of spacer length is critical for the interference of adjacent cells and should be carefully optimized according to specific cell operation conditions. The gate stack shape is also found to be an important factor affecting the lateral charge migration. Our results provide guidance for high density and high reliability 3D CTM integration. Project supported by the National Natural Science Foundation of China (Nos. 61474137, 61176073, 61306107).

  19. A simple method to produce 2D and 3D microfluidic paper-based analytical devices for clinical analysis.

    PubMed

    de Oliveira, Ricardo A G; Camargo, Fiamma; Pesquero, Naira C; Faria, Ronaldo Censi

    2017-03-08

    This paper describes the fabrication of 2D and 3D microfluidic paper-based analytical devices (μPADs) for monitoring glucose, total protein, and nitrite in blood serum and artificial urine. A new method of cutting and sealing filter paper to construct μPADs was demonstrated. Using an inexpensive home cutter printer soft cellulose-based filter paper was easily and precisely cut to produce pattern hydrophilic microchannels. 2D and 3D μPADs were designed with three detection zones each for the colorimetric detection of the analytes. A small volume of samples was added to the μPADs, which was photographed after 15 min using a digital camera. Both μPADs presented an excellent analytical performance for all analytes. The 2D device was applied in artificial urine samples and reached limits of detection (LODs) of 0.54 mM, 5.19 μM, and 2.34 μM for glucose, protein, and nitrite, respectively. The corresponding LODs of the 3D device applied for detecting the same analytes in artificial blood serum were 0.44 mM, 1.26 μM, and 4.35 μM.

  20. A quantitative study of 3D-scanning frequency and Δd of tracking points on the tooth surface

    PubMed Central

    Li, Hong; Lyu, Peijun; Sun, Yuchun; Wang, Yong; Liang, Xiaoyue

    2015-01-01

    Micro-movement of human jaws in the resting state might influence the accuracy of direct three-dimensional (3D) measurement. Providing a reference for sampling frequency settings of intraoral scanning systems to overcome this influence is important. In this study, we measured micro-movement, or change in distance (∆d), as the change in position of a single tracking point from one sampling time point to another in five human subjects. ∆d of tracking points on incisors at 7 sampling frequencies was judged against the clinical accuracy requirement to select proper sampling frequency settings. The curve equation was then fit quantitatively between ∆d median and the sampling frequency to predict the trend of ∆d with increasing f. The difference of ∆d among the subjects and the difference between upper and lower incisor feature points of the same subject were analyzed by a non-parametric test (α = 0.05). Significant differences of incisor feature points were noted among different subjects and between upper and lower jaws of the same subject (P < 0.01). Overall, ∆d decreased with increasing frequency. When the frequency was 60 Hz, ∆d nearly reached the clinical accuracy requirement. Frequencies higher than 60 Hz did not significantly decrease Δd further. PMID:26400112

  1. Optical sectioning and 3D reconstructions as an alternative to scanning electron microscopy for analysis of cell shape1

    PubMed Central

    Landis, Jacob B.; Ventura, Kayla L.; Soltis, Douglas E.; Soltis, Pamela S.; Oppenheimer, David G.

    2015-01-01

    Premise of the study: Visualizing flower epidermal cells is often desirable for investigating the interaction between flowers and their pollinators, in addition to the broader range of ecological interactions in which flowers are involved. We developed a protocol for visualizing petal epidermal cells without the limitations of the commonly used method of scanning electron microscopy (SEM). Methods: Flower material was collected and fixed in glutaraldehyde, followed by dehydration in an ethanol series. Flowers were dissected to collect petals, and subjected to a Histo-Clear series to remove the cuticle. Material was then stained with aniline blue, mounted on microscope slides, and imaged using a compound fluorescence microscope to obtain optical sections that were reconstructed into a 3D image. Results: This optical sectioning method yielded high-quality images of the petal epidermal cells with virtually no damage to cells. Flowers were processed in larger batches than are possible using common SEM methods. Also, flower size was not a limiting factor as often observed in SEM studies. Flowers up to 5 cm in length were processed and mounted for visualization. Conclusions: This method requires no special equipment for sample preparation prior to imaging and should be seen as an alternative method to SEM. PMID:25909040

  2. Target-tilt and vertical-hemifield asymmetries in free-scan search for 3-D targets.

    PubMed

    Previc, F H; Naegele, P D

    2001-04-01

    In this study, asymmetries in finding pictorial 3-D targets defined by their tilt and rotation in space were investigated by means of a free-scan search task. In Experiment 1, feature search for cube tilt and rotation, as assessed by a spatial forced-choice task, was slow but still exhibited a characteristic "flat" slope; it was also much faster to upward-tilted cubes and to targets located in the upper half of the search field. Faster search times for cubes and rectangular solids in the upper field, an advantage for upward-tilted cubes, and a strong interaction between target tilt and direction of lighting (upward or downward) for the rectangular solids were all demonstrated in Experiment 2. Finally, an advantage in searching for tilted cubes located in the upper half of the display was shown in Experiment 3, which used a present-absent search task. The results of this study confirm that the upper-field bias in visual search is due mainly to a biased search mechanism and not to the features of the target stimulus or to specific ecological factors.

  3. Reproducible preparation of nanospray tips for capillary electrophoresis coupled to mass spectrometry using 3D printed grinding device.

    PubMed

    Tycova, Anna; Prikryl, Jan; Foret, Frantisek

    2016-04-01

    The use of high quality fused silica capillary nanospray tips is critical for obtaining reliable and reproducible electrospray/MS data; however, reproducible laboratory preparation of such tips is a challenging task. In this work, we report on the design and construction of low-cost grinding device assembled from 3D printed and commercially easily available components. Detailed description and characterization of the grinding device is complemented by freely accessible files in stl and skp format allowing easy laboratory replication of the device. The process of sharpening is aimed at achieving maximal symmetricity, surface smoothness and repeatability of the conus shape. Moreover, the presented grinding device brings possibility to fabricate the nanospray tips of desired dimensions regardless of the commercial availability. On several samples of biological nature (reserpine, rabbit plasma, and the mixture of three aminoacids), performance of fabricated tips is shown on CE coupled to MS analysis. The special interest is paid to the effect of tip sharpness.

  4. Digital micromirror device (DMD)-based 3D printing of poly(propylene fumarate) scaffolds.

    PubMed

    Mott, Eric J; Busso, Mallory; Luo, Xinyi; Dolder, Courtney; Wang, Martha O; Fisher, John P; Dean, David

    2016-04-01

    Our recent investigations into the 3D printing of poly(propylene fumarate) (PPF), a linear polyester, using a DMD-based system brought us to a resin that used titanium dioxide (TiO2) as an ultraviolet (UV) filter for controlling cure depth. However, this material hindered the 3D printing process due to undesirable lateral or "dark" curing (i.e., in areas not exposed to light from the DMD chip). Well known from its use in sunscreen, another UV filter, oxybenzone, has previously been used in conjunction with TiO2. In this study we hypothesize that combining these two UV filters will result in a synergistic effect that controls cure depth and avoids dark cure. A resin mixture (i.e., polymer, initiator, UV filters) was identified that worked well. The resin was then further characterized through mechanical testing, cure testing, and cytotoxicity testing to investigate its use as a material for bone tissue engineering scaffolds. Results show that the final resin eliminated dark cure as shown through image analysis. Mechanically the new scaffolds proved to be far weaker than those printed from previous resins, with compressive strengths of 7.8 ± 0.5 MPa vs. 36.5 ± 1.6 MPa, respectively. The new scaffolds showed a 90% reduction in elastic modulus and a 74% increase in max strain. These properties may be useful in tissue engineering applications where resorption is required. Initial cytotoxicity evaluation was negative. As hypothesized, the use of TiO2 and oxybenzone showed synergistic effects in the 3D printing of PPF tissue engineering scaffolds.

  5. Simulating The Technological Movements Of The Equipment Used For Manufacturing Prosthetic Devices Using 3D Models

    NASA Astrophysics Data System (ADS)

    Chicea, Anca-Lucia

    2015-09-01

    The paper presents the process of building geometric and kinematic models of a technological equipment used in the process of manufacturing devices. First, the process of building the model for a six axes industrial robot is presented. In the second part of the paper, the process of building the model for a five-axis CNC milling machining center is also shown. Both models can be used for accurate cutting processes simulation of complex parts, such as prosthetic devices.

  6. A spheroid toxicity assay using magnetic 3D bioprinting and real-time mobile device-based imaging

    PubMed Central

    Tseng, Hubert; Gage, Jacob A.; Shen, Tsaiwei; Haisler, William L.; Neeley, Shane K.; Shiao, Sue; Chen, Jianbo; Desai, Pujan K.; Liao, Angela; Hebel, Chris; Raphael, Robert M.; Becker, Jeanne L.; Souza, Glauco R.

    2015-01-01

    An ongoing challenge in biomedical research is the search for simple, yet robust assays using 3D cell cultures for toxicity screening. This study addresses that challenge with a novel spheroid assay, wherein spheroids, formed by magnetic 3D bioprinting, contract immediately as cells rearrange and compact the spheroid in relation to viability and cytoskeletal organization. Thus, spheroid size can be used as a simple metric for toxicity. The goal of this study was to validate spheroid contraction as a cytotoxic endpoint using 3T3 fibroblasts in response to 5 toxic compounds (all-trans retinoic acid, dexamethasone, doxorubicin, 5′-fluorouracil, forskolin), sodium dodecyl sulfate (+control), and penicillin-G (−control). Real-time imaging was performed with a mobile device to increase throughput and efficiency. All compounds but penicillin-G significantly slowed contraction in a dose-dependent manner (Z’ = 0.88). Cells in 3D were more resistant to toxicity than cells in 2D, whose toxicity was measured by the MTT assay. Fluorescent staining and gene expression profiling of spheroids confirmed these findings. The results of this study validate spheroid contraction within this assay as an easy, biologically relevant endpoint for high-throughput compound screening in representative 3D environments. PMID:26365200

  7. Low cost production of 3D-printed devices and electrostimulation chambers for the culture of primary neurons.

    PubMed

    Wardyn, Joanna D; Sanderson, Chris; Swan, Laura E; Stagi, Massimiliano

    2015-08-15

    The analysis of primary neurons is a basic requirement for many areas of neurobiology. However, the range of commercial systems available for culturing primary neurons is functionally limiting, and the expense of these devices is a barrier to both exploratory and large-scale studies. This is especially relevant as primary neurons often require unusual geometries and specialised coatings for optimum growth. Fortunately, the recent revolution in 3D printing offers the possibility to generate customised devices, which can support neuronal growth and constrain neurons in defined paths, thereby enabling many aspects of neuronal physiology to be studied with relative ease. In this article, we provide a detailed description of the system hardware and software required to produce affordable 3D-printed culture devices, which are also compatible with live-cell imaging. In addition, we also describe how to use these devices to grow and stimulate neurons within geometrically constrained compartments and provide examples to illustrate the practical utility and potential that these protocols offer for many aspects of experimental neurobiology.

  8. Low cost production of 3D-printed devices and electrostimulation chambers for the culture of primary neurons

    PubMed Central

    Wardyn, Joanna D.; Sanderson, Chris; Swan, Laura E.; Stagi, Massimiliano

    2015-01-01

    The analysis of primary neurons is a basic requirement for many areas of neurobiology. However, the range of commercial systems available for culturing primary neurons is functionally limiting, and the expense of these devices is a barrier to both exploratory and large-scale studies. This is especially relevant as primary neurons often require unusual geometries and specialised coatings for optimum growth. Fortunately, the recent revolution in 3D printing offers the possibility to generate customised devices, which can support neuronal growth and constrain neurons in defined paths, thereby enabling many aspects of neuronal physiology to be studied with relative ease. In this article, we provide a detailed description of the system hardware and software required to produce affordable 3D-printed culture devices, which are also compatible with live-cell imaging. In addition, we also describe how to use these devices to grow and stimulate neurons within geometrically constrained compartments and provide examples to illustrate the practical utility and potential that these protocols offer for many aspects of experimental neurobiology. PMID:25962333

  9. Rollable Microfluidic Systems with Microscale Bending Radius and Tuning of Device Function with Reconfigurable 3D Channel Geometry.

    PubMed

    Kim, Jihye; You, Jae Bem; Nam, Sung Min; Seo, Sumin; Im, Sung Gap; Lee, Wonhee

    2017-03-29

    Flexible microfluidic system is an essential component of wearable biosensors to handle body fluids. A parylene-based, thin-film microfluidic system is developed to achieve flexible microfluidics with microscale bending radius. A new molding and bonding technique is developed for parylene microchannel fabrication. Bonding with nanoadhesive layers deposited by initiated chemical vapor deposition (iCVD) enables the construction of microfluidic channels with short fabrication time and high bonding strength. The high mechanical strength of parylene allows less channel deformation from the internal pressure for the thin-film parylene channel than bulk PDMS channel. At the same time, negligible channel sagging or collapse is observed during channel bending down to a few hundreds of micrometers due to stress relaxation by prestretch structure. The flexible parylene channels are also developed into a rollable microfluidic system. In a rollable microfluidics format, 2D parylene channels can be rolled around a capillary tubing working as inlets to minimize the device footprint. In addition, we show that creating reconfigurable 3D channel geometry with microscale bending radius can lead to tunable device function: tunable Dean-flow mixer is demonstrated using reconfigurable microscale 3D curved channel. Flexible parylene microfluidics with microscale bending radius is expected to provide an important breakthrough for many fields including wearable biosensors and tunable 3D microfluidics.

  10. Fabrication of continuous flow microfluidics device with 3D electrode structures for high throughput DEP applications using mechanical machining.

    PubMed

    Zeinali, Soheila; Çetin, Barbaros; Oliaei, Samad Nadimi Bavil; Karpat, Yiğit

    2015-07-01

    Microfluidics is the combination of micro/nano fabrication techniques with fluid flow at microscale to pursue powerful techniques in controlling and manipulating chemical and biological processes. Sorting and separation of bio-particles are highly considered in diagnostics and biological analyses. Dielectrophoresis (DEP) has offered unique advantages for microfluidic devices. In DEP devices, asymmetric pair of planar electrodes could be employed to generate non-uniform electric fields. In DEP applications, facing 3D sidewall electrodes is considered to be one of the key solutions to increase device throughput due to the generated homogeneous electric fields along the height of microchannels. Despite the advantages, fabrication of 3D vertical electrodes requires a considerable challenge. In this study, two alternative fabrication techniques have been proposed for the fabrication of a microfluidic device with 3D sidewall electrodes. In the first method, both the mold and the electrodes are fabricated using high precision machining. In the second method, the mold with tilted sidewalls is fabricated using high precision machining and the electrodes are deposited on the sidewall using sputtering together with a shadow mask fabricated by electric discharge machining. Both fabrication processes are assessed as highly repeatable and robust. Moreover, the two methods are found to be complementary with respect to the channel height. Only the manipulation of particles with negative-DEP is demonstrated in the experiments, and the throughput values up to 105 particles / min is reached in a continuous flow. The experimental results are compared with the simulation results and the limitations on the fabrication techniques are also discussed.

  11. Method for dose-reduced 3D catheter tracking on a scanning-beam digital x-ray system using dynamic electronic collimation

    PubMed Central

    Dunkerley, David A. P.; Funk, Tobias; Speidel, Michael A.

    2016-01-01

    Scanning-beam digital x-ray (SBDX) is an inverse geometry x-ray fluoroscopy system capable of tomosynthesis-based 3D catheter tracking. This work proposes a method of dose-reduced 3D tracking using dynamic electronic collimation (DEC) of the SBDX scanning x-ray tube. Positions in the 2D focal spot array are selectively activated to create a region-of-interest (ROI) x-ray field around the tracked catheter. The ROI position is updated for each frame based on a motion vector calculated from the two most recent 3D tracking results. The technique was evaluated with SBDX data acquired as a catheter tip inside a chest phantom was pulled along a 3D trajectory. DEC scans were retrospectively generated from the detector images stored for each focal spot position. DEC imaging of a catheter tip in a volume measuring 11.4 cm across at isocenter required 340 active focal spots per frame, versus 4473 spots in full-FOV mode. The dose-area-product (DAP) and peak skin dose (PSD) for DEC versus full field-of-view (FOV) scanning were calculated using an SBDX Monte Carlo simulation code. DAP was reduced to 7.4% to 8.4% of the full-FOV value, consistent with the relative number of active focal spots (7.6%). For image sequences with a moving catheter, PSD was 33.6% to 34.8% of the full-FOV value. The root-mean-squared-deviation between DEC-based 3D tracking coordinates and full-FOV 3D tracking coordinates was less than 0.1 mm. The 3D distance between the tracked tip and the sheath centerline averaged 0.75 mm. Dynamic electronic collimation can reduce dose with minimal change in tracking performance. PMID:27375314

  12. Scalable and Adaptive Streaming of 3D Mesh to Heterogeneous Devices

    NASA Astrophysics Data System (ADS)

    Abderrahim, Zeineb; Bouhlel, Mohamed Salim

    2016-12-01

    This article comprises a presentation of a web platform for the diffusion and visualization of 3D compressed data on the web. Indeed, the major goal of this work resides in the proposal of the transfer adaptation of the three-dimensional data to resources (network bandwidth, the type of visualization terminals, display resolution, user's preferences...). Also, it is an attempt to provide an effective consultation adapted to the user's request (preferences, levels of the requested detail, etc.). Such a platform can adapt the levels of detail to the change in the bandwidth and the rendering time when loading the mesh at the client level. In addition, the levels of detail are adapted to the distance between the object and the camera. These features are able to minimize the latency time and to make the real time interaction possible. The experiences as well as the comparison with the existing solutions show auspicious results in terms of latency, scalability and the quality of the experience offered to the users.

  13. Development of AN Innovative Three-Dimensional Complete Body Screening Device - 3D-CBS

    NASA Astrophysics Data System (ADS)

    Crosetto, D. B.

    2004-07-01

    This article describes an innovative technological approach that increases the efficiency with which a large number of particles (photons) can be detected and analyzed. The three-dimensional complete body screening (3D-CBS) combines the functional imaging capability of the Positron Emission Tomography (PET) with those of the anatomical imaging capability of Computed Tomography (CT). The novel techniques provide better images in a shorter time with less radiation to the patient. A primary means of accomplishing this is the use of a larger solid angle, but this requires a new electronic technique capable of handling the increased data rate. This technique, combined with an improved and simplified detector assembly, enables executing complex real-time algorithms and allows more efficiently use of economical crystals. These are the principal features of this invention. A good synergy of advanced techniques in particle detection, together with technological progress in industry (latest FPGA technology) and simple, but cost-effective ideas provide a revolutionary invention. This technology enables over 400 times PET efficiency improvement at once compared to two to three times improvements achieved every five years during the past decades. Details of the electronics are provided, including an IBM PC board with a parallel-processing architecture implemented in FPGA, enabling the execution of a programmable complex real-time algorithm for best detection of photons.

  14. Modal liquid crystal devices in optical tweezing: 3D control and oscillating potential wells.

    PubMed

    Hands, Philip J W; Tatarkova, Svetlana A; Kirby, Andrew K; Love, Gordon D

    2006-05-15

    We investigate the use of liquid crystal (LC) adaptive optics elements to provide full 3 dimensional particle control in an optical tweezer. These devices are suitable for single controllable traps, and so are less versatile than many of the competing technologies which can be used to control multiple particles. However, they have the advantages of simplicity and light efficiency. Furthermore, compared to binary holographic optical traps they have increased positional accuracy. The transmissive LC devices could be retro-fitted to an existing microscope system. An adaptive modal LC lens is used to vary the z-focal position over a range of up to 100 mum and an adaptive LC beam-steering device is used to deflect the beam (and trapped particle) in the x-y plane within an available radius of 10 mum. Furthermore, by modifying the polarisation of the incident light, these LC components also offer the opportunity for the creation of dual optical traps of controllable depth and separation.

  15. Modal liquid crystal devices in optical tweezing: 3D control and oscillating potential wells

    NASA Astrophysics Data System (ADS)

    Hands, Philip J. W.; Tatarkova, Svetlana A.; Kirby, Andrew K.; Love, Gordon D.

    2006-05-01

    We investigate the use of liquid crystal (LC) adaptive optics elements to provide full 3 dimensional particle control in an optical tweezer. These devices are suitable for single controllable traps, and so are less versatile than many of the competing technologies which can be used to control multiple particles. However, they have the advantages of simplicity and light efficiency. Furthermore, compared to binary holographic optical traps they have increased positional accuracy. The transmissive LC devices could be retro-fitted to an existing microscope system. An adaptive modal LC lens is used to vary the z-focal position over a range of up to 100 μm and an adaptive LC beam-steering device is used to deflect the beam (and trapped particle) in the x-y plane within an available radius of 10 μm. Furthermore, by modifying the polarisation of the incident light, these LC components also offer the opportunity for the creation of dual optical traps of controllable depth and separation.

  16. Characterization of a subwavelength-scale 3D void structure using the FDTD-based confocal laser scanning microscopic image mapping technique.

    PubMed

    Choi, Kyongsik; Chon, James W; Gu, Min; Lee, Byoungho

    2007-08-20

    In this paper, a simple confocal laser scanning microscopic (CLSM) image mapping technique based on the finite-difference time domain (FDTD) calculation has been proposed and evaluated for characterization of a subwavelength-scale three-dimensional (3D) void structure fabricated inside polymer matrix. The FDTD simulation method adopts a focused Gaussian beam incident wave, Berenger's perfectly matched layer absorbing boundary condition, and the angular spectrum analysis method. Through the well matched simulation and experimental results of the xz-scanned 3D void structure, we first characterize the exact position and the topological shape factor of the subwavelength-scale void structure, which was fabricated by a tightly focused ultrashort pulse laser. The proposed CLSM image mapping technique based on the FDTD can be widely applied from the 3D near-field microscopic imaging, optical trapping, and evanescent wave phenomenon to the state-of-the-art bio- and nanophotonics.

  17. The Structure of the Kaali Impact Crater (Estonia) Based on 3D Laser Scanning, Electro-Resistivity Tomography, and iSale Hydrocode Modelling

    NASA Astrophysics Data System (ADS)

    Zanetti, M.; Wilk, J.; Kukko, A.; Kaartinen, H.; Kohv, M.; Jõeleht, A.; Välja, R.; Paavel, K.; Kriiska, A.; Plado, J.; Losiak, A.; Wisniowski, T.; Huber, M.; Zhu, M. H.

    2015-09-01

    A field investigation using 3D laser scans, ERT, and strike and dip measurements has produced the highest resolution DEM and structural characterization of the Kaali Main crater to date. We use field measurements to constrain iSale formation models.

  18. Micro 3D cell culture systems for cellular behavior studies: Culture matrices, devices, substrates, and in-situ sensing methods.

    PubMed

    Choi, Jonghoon; Lee, Eun Kyu; Choo, Jaebum; Yuh, Junhan; Hong, Jong Wook

    2015-09-01

    Microfabricated systems equipped with 3D cell culture devices and in-situ cellular biosensing tools can be a powerful bionanotechnology platform to investigate a variety of biomedical applications. Various construction substrates such as plastics, glass, and paper are used for microstructures. When selecting a construction substrate, a key consideration is a porous microenvironment that allows for spheroid growth and mimics the extracellular matrix (ECM) of cell aggregates. Various bio-functionalized hydrogels are ideal candidates that mimic the natural ECM for 3D cell culture. When selecting an optimal and appropriate microfabrication method, both the intended use of the system and the characteristics and restrictions of the target cells should be carefully considered. For highly sensitive and near-cell surface detection of excreted cellular compounds, SERS-based microsystems capable of dual modal imaging have the potential to be powerful tools; however, the development of optical reporters and nanoprobes remains a key challenge. We expect that the microsystems capable of both 3D cell culture and cellular response monitoring would serve as excellent tools to provide fundamental cellular behavior information for various biomedical applications such as metastasis, wound healing, high throughput screening, tissue engineering, regenerative medicine, and drug discovery and development.

  19. Ethylene vinyl acetate (EVA) as a new drug carrier for 3D printed medical drug delivery devices.

    PubMed

    Genina, Natalja; Holländer, Jenny; Jukarainen, Harri; Mäkilä, Ermei; Salonen, Jarno; Sandler, Niklas

    2016-07-30

    The main purpose of this work was to investigate the printability of different grades of ethylene vinyl acetate (EVA) copolymers as new feedstock material for fused-deposition modeling (FDM™)-based 3D printing technology in fabrication of custom-made T-shaped intrauterine systems (IUS) and subcutaneous rods (SR). The goal was to select an EVA grade with optimal properties, namely vinyl acetate content, melting index, flexural modulus, for 3D printing of implantable prototypes with the drug incorporated within the entire matrix of the medical devices. Indomethacin was used as a model drug in this study. Out of the twelve tested grades of the EVA five were printable. One of them showed superior print quality and was further investigated by printing drug-loaded filaments, containing 5% and 15% indomethacin. The feedstock filaments were fabricated by hot-melt extrusion (HME) below the melting point of the drug substance and the IUS and SR were successfully printed at the temperature above the melting point of the drug. As a result, the drug substance in the printed prototypes showed to be at least partly amorphous, while the drug in the corresponding HME filaments was crystalline. This difference affected the drug release profiles from the filaments and printed prototype products: faster release from the prototypes over 30days in the in vitro tests. To conclude, this study indicates that certain grades of EVA were applicable feedstock material for 3D printing to produce drug-loaded implantable prototypes.

  20. SU-E-T-676: Reproducibility and Consistency of Two SunNuclear 3D Scanning Tanks

    SciTech Connect

    Hessler, J; DiCostanzo, D; Grzetic, S; Ayan, A; Gupta, N; Woollard, J

    2015-06-15

    Purpose: To determine if two Sun Nuclear 3D Scanning (SNC 3DS) tanks collect reproducible and consistent data and test the precision of the SNC Dosimetry auto-setup. Methods: Percent depth doses (PDDs) and profiles were collected on two SNC 3DS tanks with a Varian TrueBeam linear accelerator. SNC Dosimetry auto-setup application was used with CC13 ionization chambers. After auto-setup, collimator light field was checked manually against the position of the chamber. Comparing measured data for repeated measurements with tank 1 allowed evaluation of SNC-3DS auto-setup and tank reproducibility. Comparing measured data between tanks 1 and 2 allowed evaluation of consistency between tanks. Results: Preliminary results showed reproducibility of depth of maximum dose (Dmax) of 0.38mm for a 10cmx10cm field and 0.67mm for 30cmx30cm on a single tank. PDD values at 5cm, 10cm, and 20cm depths were reproducible within 0.26%. Consistency of Dmax between tanks was 0.17mm for a 10cmx10cm field and 0.44mm for 30cmx30cm. PDD values at 5cm, 10cm, and 20cmwere consistent within 0.06%. Profiles showed reproducibility in field width within 0.4mm for a 10cmx10cm field and 0.7mm for a 30cmx30cm field. Profiles showed consistency in field width within 0.2mm for 10cmx10cm and 30cmx30cm field sizes. Penumbra width was reproducible and consistent to under 0.5mm except for 30cmx30cm field size at 30cm depth where the reproducibility was 2.2mm and the consistency was 2.6mm. Conclusion: In conclusion, the SNC 3DS tank shows good reproducibility in measured data. Since the tank to tank variation in measured data is within the uncertainty of repeated single tank measurements the tanks also perform consistently.

  1. A novel device to concurrently assess leukocyte extravasation and interstitial migration within a defined 3D environment.

    PubMed

    Molteni, Raffaella; Bianchi, Elena; Patete, Paolo; Fabbri, Monica; Baroni, Guido; Dubini, Gabriele; Pardi, Ruggero

    2015-01-07

    Leukocyte extravasation and interstitial migration are key events during inflammation. Traditional in vitro techniques address only specific steps of cell recruitment to tissues and fail to recapitulate the whole process in an appropriate three-dimensional (3D) microenvironment. Herein, we describe a device that enables us to qualitatively and quantitatively assess in 4D the interdependent steps underlying leukocyte trafficking in a close-to-physiology in vitro context. Real-time tracking of cells, from initial adhesion to the endothelium and subsequent diapedesis to interstitial migration towards the source of the chemoattractant within the 3D collagen matrix, is enabled by the use of optically transparent porous membranes laid over the matrix. Unique features of the device, such as the use of non-planar surfaces and the contribution of physiological flow to the establishment of a persistent chemoattractant gradient, were assessed by numerical simulations and validated by proof-of-concept, simultaneous testing of differentially treated primary mouse neutrophils. This microfluidic platform offers new and versatile tools to thoroughly investigate the stepwise process of circulating cell recruitment to target tissues in vitro and to test novel therapeutics targeting various steps of the process.

  2. Assessment of a Microsoft Kinect-based 3D scanning system for taking body segment girth measurements: a comparison to ISAK and ISO standards.

    PubMed

    Clarkson, Sean; Wheat, Jon; Heller, Ben; Choppin, Simon

    2016-01-01

    Use of anthropometric data to infer sporting performance is increasing in popularity, particularly within elite sport programmes. Measurement typically follows standards set by the International Society for the Advancement of Kinanthropometry (ISAK). However, such techniques are time consuming, which reduces their practicality. Schranz et al. recently suggested 3D body scanners could replace current measurement techniques; however, current systems are costly. Recent interest in natural user interaction has led to a range of low-cost depth cameras capable of producing 3D body scans, from which anthropometrics can be calculated. A scanning system comprising 4 depth cameras was used to scan 4 cylinders, representative of the body segments. Girth measurements were calculated from the 3D scans and compared to gold standard measurements. Requirements of a Level 1 ISAK practitioner were met in all 4 cylinders, and ISO standards for scan-derived girth measurements were met in the 2 larger cylinders only. A fixed measurement bias was identified that could be corrected with a simple offset factor. Further work is required to determine comparable performance across a wider range of measurements performed upon living participants. Nevertheless, findings of the study suggest such a system offers many advantages over current techniques, having a range of potential applications.

  3. Accurate assessment of breast volume: a study comparing the volumetric gold standard (direct water displacement measurement of mastectomy specimen) with a 3D laser scanning technique.

    PubMed

    Yip, Jia Miin; Mouratova, Naila; Jeffery, Rebecca M; Veitch, Daisy E; Woodman, Richard J; Dean, Nicola R

    2012-02-01

    Preoperative assessment of breast volume could contribute significantly to the planning of breast-related procedures. The availability of 3D scanning technology provides us with an innovative method for doing this. We performed this study to compare measurements by this technology with breast volume measurement by water displacement. A total of 30 patients undergoing 39 mastectomies were recruited from our center. The volume of each patient's breast(s) was determined with a preoperative 3D laser scan. The volume of the mastectomy specimen was then measured in the operating theater by water displacement. There was a strong linear association between breast volumes measured using the 2 different methods when using a Pearson correlation (r = 0.95, P < 0.001). The mastectomy mean volume was defined by the equation: mastectomy mean volume = (scan mean volume × 1.03) -70.6. This close correlation validates the Cyberware WBX Scanner as a tool for assessment of breast volume.

  4. LANSCE wire scanning diagnostics device mechanical design

    SciTech Connect

    Rodriguez Esparza, Sergio

    2010-01-01

    The Los Alamos Neutron Science Center (LANSCE) is one of the major experimental science facilities at the Los Alamos National Laboratory (LANL). The core of LANSCE's work lies in the operation of a powerful linear accelerator, which accelerates protons up to 84% the speed oflight. These protons are used for a variety of purposes, including materials testing, weapons research and isotopes production. To assist in guiding the proton beam, a series of over one hundred wire scanners are used to measure the beam profile at various locations along the half-mile length of the particle accelerator. A wire scanner is an electro-mechanical device that moves a set of wires through a particle beam and measures the secondary emissions from the resulting beam-wire interaction to obtain beam intensity information. When supplemented with data from a position sensor, this information is used to determine the cross-sectional profile of the beam. This measurement allows beam operators to adjust parameters such as acceleration, beam steering, and focus to ensure that the beam reaches its destination as effectively as possible. Some of the current wire scanners are nearly forty years old and are becoming obsolete. The problem with current wire scanners comes in the difficulty of maintenance and reliability. The designs of these wire scanners vary making it difficult to keep spare parts that would work on all designs. Also many of the components are custom built or out-dated technology and are no longer in production.

  5. The Use of 3d Scanning and Photogrammetry Techniques in the Case Study of the Roman Theatre of Nikopolis. Surveying, Virtual Reconstruction and Restoration Study.

    NASA Astrophysics Data System (ADS)

    Bilis, T.; Kouimtzoglou, T.; Magnisali, M.; Tokmakidis, P.

    2017-02-01

    The aim of this paper is to present the specific methods by which 3D scanning and photogrammetric techniques were incorporated into the architectural study, the documentation and the graphic restoration study of the monument of the ancient theatre of Nikopolis. Traditional methods of surveying were enhanced by the use of 3D scanning and image-based 3D reconstruction and 3D remodelling and renderings. For this reason, a team of specialists from different scientific fields has been organized. This presented the opportunity to observe every change of the restoration design process, not only by the use of common elevations and ground plans, but also in 3D space. It has been also very liberating to know how the monument will look like in this unique site after the restoration, so as to obtain at the study stage the best intervention decisions possible. Moreover, these modern work tools helped of course to convince the authorities for the accuracy of the restoration actions and finally to make the proposal clear to the public.

  6. The use of a low cost 3D scanning and printing tool in the manufacture of custom-made foot orthoses: a preliminary study

    PubMed Central

    2014-01-01

    Background Custom foot orthoses are currently recognized as the gold standard for treatment of foot and lower limb pathology. While foam and plaster casting methods are most widely used in clinical practice, technology has emerged, permitting the use of 3D scanning, computer aided design (CAD) and computer aided manufacturing (CAM) for fabrication of foot molds and custom foot orthotic components. Adoption of 3D printing, as a form of CAM, requires further investigation for use as a clinical tool. This study provides a preliminary description of a new method to manufacture foot orthoses using a novel 3D scanner and printer and compare gait kinematic outputs from shod and traditional plaster casted orthotics. Findings One participant (male, 25 years) was included with no lower extremity injuries. Foot molds were created from both plaster casting and 3D scanning/printing methods. Custom foot orthoses were then fabricated from each mold. Lower body plug-in-gait with the Oxford Foot Model on the right foot was collected for both orthotic and control (shod) conditions. The medial longitudinal arch was measured using arch height index (AHI) where a decrease in AHI represented a drop in arch height. The lowest AHI was 21.2 mm in the running shoes, followed by 21.4 mm wearing the orthoses made using 3D scanning and printing, with the highest AHI of 22.0 mm while the participant wore the plaster casted orthoses. Conclusion This preliminary study demonstrated a small increase in AHI with the 3D printing orthotic compared to the shod condition. A larger sample size may demonstrate significant patterns for the tested conditions. PMID:25015013

  7. Rapid and Low-cost Prototyping of Medical Devices Using 3D Printed Molds for Liquid Injection Molding

    PubMed Central

    Chung, Philip; Heller, J. Alex; Etemadi, Mozziyar; Ottoson, Paige E.; Liu, Jonathan A.; Rand, Larry; Roy, Shuvo

    2014-01-01

    Biologically inert elastomers such as silicone are favorable materials for medical device fabrication, but forming and curing these elastomers using traditional liquid injection molding processes can be an expensive process due to tooling and equipment costs. As a result, it has traditionally been impractical to use liquid injection molding for low-cost, rapid prototyping applications. We have devised a method for rapid and low-cost production of liquid elastomer injection molded devices that utilizes fused deposition modeling 3D printers for mold design and a modified desiccator as an injection system. Low costs and rapid turnaround time in this technique lower the barrier to iteratively designing and prototyping complex elastomer devices. Furthermore, CAD models developed in this process can be later adapted for metal mold tooling design, enabling an easy transition to a traditional injection molding process. We have used this technique to manufacture intravaginal probes involving complex geometries, as well as overmolding over metal parts, using tools commonly available within an academic research laboratory. However, this technique can be easily adapted to create liquid injection molded devices for many other applications. PMID:24998993

  8. Rapid and low-cost prototyping of medical devices using 3D printed molds for liquid injection molding.

    PubMed

    Chung, Philip; Heller, J Alex; Etemadi, Mozziyar; Ottoson, Paige E; Liu, Jonathan A; Rand, Larry; Roy, Shuvo

    2014-06-27

    Biologically inert elastomers such as silicone are favorable materials for medical device fabrication, but forming and curing these elastomers using traditional liquid injection molding processes can be an expensive process due to tooling and equipment costs. As a result, it has traditionally been impractical to use liquid injection molding for low-cost, rapid prototyping applications. We have devised a method for rapid and low-cost production of liquid elastomer injection molded devices that utilizes fused deposition modeling 3D printers for mold design and a modified desiccator as an injection system. Low costs and rapid turnaround time in this technique lower the barrier to iteratively designing and prototyping complex elastomer devices. Furthermore, CAD models developed in this process can be later adapted for metal mold tooling design, enabling an easy transition to a traditional injection molding process. We have used this technique to manufacture intravaginal probes involving complex geometries, as well as overmolding over metal parts, using tools commonly available within an academic research laboratory. However, this technique can be easily adapted to create liquid injection molded devices for many other applications.

  9. Optical scanning holography based on compressive sensing using a digital micro-mirror device

    NASA Astrophysics Data System (ADS)

    A-qian, Sun; Ding-fu, Zhou; Sheng, Yuan; You-jun, Hu; Peng, Zhang; Jian-ming, Yue; xin, Zhou

    2017-02-01

    Optical scanning holography (OSH) is a distinct digital holography technique, which uses a single two-dimensional (2D) scanning process to record the hologram of a three-dimensional (3D) object. Usually, these 2D scanning processes are in the form of mechanical scanning, and the quality of recorded hologram may be affected due to the limitation of mechanical scanning accuracy and unavoidable vibration of stepper motor's start-stop. In this paper, we propose a new framework, which replaces the 2D mechanical scanning mirrors with a Digital Micro-mirror Device (DMD) to modulate the scanning light field, and we call it OSH based on Compressive Sensing (CS) using a digital micro-mirror device (CS-OSH). CS-OSH can reconstruct the hologram of an object through the use of compressive sensing theory, and then restore the image of object itself. Numerical simulation results confirm this new type OSH can get a reconstructed image with favorable visual quality even under the condition of a low sample rate.

  10. The implications of free 3D scanning in the conservation state assessment of old wood painted icon

    NASA Astrophysics Data System (ADS)

    Munteanu, Marius; Sandu, Ion

    2016-06-01

    The present paper presents the conservation state and the making of a 3D model of a XVIII-th century orthodox icon on wood support, using free available software and cloud computing. In order to create the 3D model of the painting layer of the icon a number of 70 pictures were taken using a Nikon DSLR D3300, 24.2 MP in setup with a Hama Star 75 photo tripod, in loops 360° around the painting, at three different angles. The pictures were processed with Autodesk I23D Catch, which automatically finds and matches common features among all of the uploaded photographs in order to create the 3D scene, using the power and speed of cloud computing. The obtained 3D model was afterwards analyzed and processed in order to obtain a final version, which can now be use to better identify, to map and to prioritize the future conservation processes and finally can be shared online as an animation.

  11. Static and dynamic fatigue behavior of topology designed and conventional 3D printed bioresorbable PCL cervical interbody fusion devices.

    PubMed

    Knutsen, Ashleen R; Borkowski, Sean L; Ebramzadeh, Edward; Flanagan, Colleen L; Hollister, Scott J; Sangiorgio, Sophia N

    2015-09-01

    Recently, as an alternative to metal spinal fusion cages, 3D printed bioresorbable materials have been explored; however, the static and fatigue properties of these novel cages are not well known. Unfortunately, current ASTM testing standards used to determine these properties were designed prior to the advent of bioresorbable materials for cages. Therefore, the applicability of these standards for bioresorbable materials is unknown. In this study, an image-based topology and a conventional 3D printed bioresorbable poly(ε)-caprolactone (PCL) cervical cage design were tested in compression, compression-shear, and torsion, to establish their static and fatigue properties. Difficulties were in fact identified in establishing failure criteria and in particular determining compressive failure load. Given these limitations, under static loads, both designs withstood loads of over 650 N in compression, 395 N in compression-shear, and 0.25 Nm in torsion, prior to yielding. Under dynamic testing, both designs withstood 5 million (5M) cycles of compression at 125% of their respective yield forces. Geometry significantly affected both the static and fatigue properties of the cages. The measured compressive yield loads fall within the reported physiological ranges; consequently, these PCL bioresorbable cages would likely require supplemental fixation. Most importantly, supplemental testing methods may be necessary beyond the current ASTM standards, to provide more accurate and reliable results, ultimately improving preclinical evaluation of these devices.

  12. Static and Dynamic Fatigue Behavior of Topology Designed and Conventional 3D Printed Bioresorbable PCL Cervical Interbody Fusion Devices

    PubMed Central

    Knutsen, Ashleen R.; Borkowski, Sean L.; Ebramzadeh, Edward; Flanagan, Colleen L.; Hollister, Scott J.; Sangiorgio, Sophia N.

    2015-01-01

    Recently, as an alternative to metal spinal fusion cages, 3D printed bioresorbable materials have been explored; however, the static and fatigue properties of these novel cages are not well known. Unfortunately, current ASTM testing standards used to determine these properties were designed prior to the advent of bioresorbable materials for cages. Therefore, the applicability of these standards for bioresorbable materials is unknown. In this study, an image-based topology and a conventional 3D printed bioresorbable poly(ε)-caprolactone (PCL) cervical cage design were tested in compression, compression-shear, and torsion, to establish their static and fatigue properties. Difficulties were in fact identified in establishing failure criteria and in particular determining compressive failure load. Given these limitations, under static loads, both designs withstood loads of over 650N in compression, 395N in compression-shear, and 0.25Nm in torsion, prior to yielding. Under dynamic testing, both designs withstood 5 million (5M) cycles of compression at 125% of their respective yield forces. Geometry significantly affected both the static and fatigue properties of the cages. The measured compressive yield loads fall within the reported physiological ranges; consequently, these PCL bioresorbable cages would likely require supplemental fixation. Most importantly, supplemental testing methods may be necessary beyond the current ASTM standards, to provide more accurate and reliable results, ultimately improving preclinical evaluation of these devices. PMID:26072198

  13. 3D Micro-topography of Transferred Laboratory and Natural Ice Crystal Surfaces Imaged by Cryo and Environmental Scanning Electron Microscopy

    NASA Astrophysics Data System (ADS)

    Magee, N. B.; Boaggio, K.; Bancroft, L.; Bandamede, M.

    2015-12-01

    Recent work has highlighted micro-scale roughness on the surfaces of ice crystals grown and imaged in-situ within the chambers of environmental scanning electron microscopes (ESEM). These observations appear to align with theoretical and satellite observations that suggest a prevalence of rough ice in cirrus clouds. However, the atmospheric application of the lab observations are indeterminate because the observations have been based only on crystals grown on substrates and in pure-water vapor environments. In this work, we present details and results from the development of a transfer technique which allows natural and lab-grown ice and snow crystals to be captured, preserved, and transferred into the ESEM for 3D imaging. Ice crystals were gathered from 1) natural snow, 2) a balloon-borne cirrus particle capture device, and 3) lab-grown ice crystals from a diffusion chamber. Ice crystals were captured in a pre-conditioned small-volume (~1 cm3) cryo-containment cell. The cell was then sealed closed and transferred to a specially-designed cryogenic dewer (filled with liquid nitrogen or crushed dry ice) for transport to a new Hitachi Field Emission, Variable Pressure SEM (SU-5000). The cryo-cell was then removed from the dewer and quickly placed onto the pre-conditioned cryo transfer stage attached to the ESEM (Quorum 3010T). Quantitative 3D topographical digital elevation models of ice surfaces are reported from SEM for the first time, including a variety of objective measures of statistical surface roughness. The surfaces of the transported crystals clearly exhibit signatures of mesoscopic roughening that are similar to examples of roughness seen in ESEM-grown crystals. For most transported crystals, the habits and crystal edges are more intricate that those observed for ice grown directly on substrates within the ESEM chamber. Portions of some crystals do appear smooth even at magnification greater than 1000x, a rare observation in our ESEM-grown crystals. The

  14. Dynamic DNA devices and assemblies formed by shape-complementary, non-base pairing 3D components.

    PubMed

    Gerling, Thomas; Wagenbauer, Klaus F; Neuner, Andrea M; Dietz, Hendrik

    2015-03-27

    We demonstrate that discrete three-dimensional (3D) DNA components can specifically self-assemble in solution on the basis of shape-complementarity and without base pairing. Using this principle, we produced homo- and heteromultimeric objects, including micrometer-scale one- and two-stranded filaments and lattices, as well as reconfigurable devices, including an actuator, a switchable gear, an unfoldable nanobook, and a nanorobot. These multidomain assemblies were stabilized via short-ranged nucleobase stacking bonds that compete against electrostatic repulsion between the components' interfaces. Using imaging by electron microscopy, ensemble and single-molecule fluorescence resonance energy transfer spectroscopy, and electrophoretic mobility analysis, we show that the balance between attractive and repulsive interactions, and thus the conformation of the assemblies, may be finely controlled by global parameters such as cation concentration or temperature and by an allosteric mechanism based on strand-displacement reactions.

  15. Dynamic DNA devices and assemblies formed by shape-complementary, non-base pairing 3D components

    NASA Astrophysics Data System (ADS)

    Gerling, Thomas; Wagenbauer, Klaus F.; Neuner, Andrea M.; Dietz, Hendrik

    2015-03-01

    We demonstrate that discrete three-dimensional (3D) DNA components can specifically self-assemble in solution on the basis of shape-complementarity and without base pairing. Using this principle, we produced homo- and heteromultimeric objects, including micrometer-scale one- and two-stranded filaments and lattices, as well as reconfigurable devices, including an actuator, a switchable gear, an unfoldable nanobook, and a nanorobot. These multidomain assemblies were stabilized via short-ranged nucleobase stacking bonds that compete against electrostatic repulsion between the components’ interfaces. Using imaging by electron microscopy, ensemble and single-molecule fluorescence resonance energy transfer spectroscopy, and electrophoretic mobility analysis, we show that the balance between attractive and repulsive interactions, and thus the conformation of the assemblies, may be finely controlled by global parameters such as cation concentration or temperature and by an allosteric mechanism based on strand-displacement reactions.

  16. Synchronized monochromator and insertion device energy scans at SLS

    SciTech Connect

    Krempasky, J.; Flechsig, U.; Korhonen, T.; Zimoch, D.; Quitmann, Ch.; Nolting, F.

    2010-06-23

    Synchronous monochromator and insertion device energy scans were implemented at the Surfaces/Interfaces:Microscopy (SIM) beamline in order to provide the users fast X-ray magnetic dichroism studies (XMCD). A simple software control scheme is proposed based on a fast monochromator run-time energy readback which quickly updates the insertion device requested energy during an on-the-fly X-ray absorption scan (XAS). In this scheme the Plain Grating Monochromator (PGM) motion control, being much slower compared with the insertion device (APPLE-II type undulator), acts as a 'master' controlling the undulator 'slave' energy position. This master-slave software implementation exploits EPICS distributed device control over computer network and allows for a quasi-synchronous motion control combined with data acquisition needed for the XAS or XMCD experiment.

  17. Synchronized monochromator and insertion device energy scans at SLS

    NASA Astrophysics Data System (ADS)

    Krempaský, J.; Flechsig, U.; Korhonen, T.; Zimoch, D.; Quitmann, Ch.; Nolting, F.

    2010-06-01

    Synchronous monochromator and insertion device energy scans were implemented at the Surfaces/Interfaces:Microscopy (SIM) beamline in order to provide the users fast X-ray magnetic dichroism studies (XMCD). A simple software control scheme is proposed based on a fast monochromator run-time energy readback which quickly updates the insertion device requested energy during an on-the-fly X-ray absorption scan (XAS). In this scheme the Plain Grating Monochromator (PGM) motion control, being much slower compared with the insertion device (APPLE-II type undulator), acts as a "master" controlling the undulator "slave" energy position. This master-slave software implementation exploits EPICS distributed device control over computer network and allows for a quasi-synchronous motion control combined with data acquisition needed for the XAS or XMCD experiment.

  18. 3D printed facial laser scans for the production of localised radiotherapy treatment masks - A case study.

    PubMed

    Briggs, Matthew; Clements, Helen; Wynne, Neil; Rennie, Allan; Kellett, Darren

    This study investigates the use of 3D printing for patients that require localised radiotherapy treatment to the face. The current process involves producing a lead mask in order to protect the healthy tissue from the effects of the radiotherapy. The mask is produced by applying a thermoplastic sheet to the patient's face and allowing to set hard. This can then be used as a mould to create a plaster impression of the patient's face. A sheet of lead is then hammered on to the plaster to create a bespoke fitted face mask. This process can be distressing for patients and can be problematic when the patient is required to remain motionless for a prolonged time while the thermoplastic sets. In this study, a 1:1 scale 3D print of a patient's face was generated using a laser scanner. The lead was hammered directly on to the surface of the 3D print in order to create a bespoke fitted treatment mask. This eliminated the thermoplastic moulding stage and significantly reduced the time needed for the patient to be in clinic. The higher definition impression of the the face resulted in a more accurate, better fitting treatment mask.

  19. Ultrasonic simulation—Imagine3D and SimScan: Tools to solve the inverse problem for complex turbine components

    NASA Astrophysics Data System (ADS)

    Mair, H. D.; Ciorau, P.; Owen, D.; Hazelton, T.; Dunning, G.

    2000-05-01

    Two ultrasonic simulation packages: Imagine 3D and SIMSCAN have specifically been developed to solve the inverse problem for blade root and rotor steeple of low-pressure turbine. The software was integrated with the 3D drawing of the inspected parts, and with the dimensions of linear phased-array probes. SIMSCAN simulates the inspection scenario in both optional conditions: defect location and probe movement/refracted angle range. The results are displayed into Imagine 3-D, with a variety of options: rendering, display 1:1, grid, generated UT beam. The results are very useful for procedure developer, training and to optimize the phased-array probe inspection sequence. A spreadsheet is generated to correlate the defect coordinates with UT data (probe position, skew and refracted angle, UT path, and probe movement). The simulation models were validated during experimental work with phased-array systems. The accuracy in probe position is ±1 mm, and the refracted/skew angle is within ±0.5°. Representative examples of phased array focal laws/probe movement for a specific defect location, are also included.

  20. A Diffusion-Based and Dynamic 3D-Printed Device That Enables Parallel in Vitro Pharmacokinetic Profiling of Molecules

    PubMed Central

    Lockwood, Sarah Y.; Meisel, Jayda E.; Monsma, Frederick J.; Spence, Dana M.

    2016-01-01

    The process of bringing a drug to market involves many steps, including the preclinical stage, where various properties of the drug candidate molecule are determined. These properties, which include drug absorption, distribution, metabolism, and excretion, are often displayed in a pharmacokinetic (PK) profile. While PK profiles are determined in animal models, in vitro systems that model in vivo processes are available, although each possesses shortcomings. Here, we present a 3D-printed, diffusion-based, and dynamic in vitro PK device. The device contains six flow channels, each with integrated porous membrane-based insert wells. The pores of these membranes enable drugs to freely diffuse back and forth between the flow channels and the inserts, thus enabling both loading and clearance portions of a standard PK curve to be generated. The device is designed to work with 96-well plate technology and consumes single-digit milliliter volumes to generate multiple PK profiles, simultaneously. Generation of PK profiles by use of the device was initially performed with fluorescein as a test molecule. Effects of such parameters as flow rate, loading time, volume in the insert well, and initial concentration of the test molecule were investigated. A prediction model was generated from this data, enabling the user to predict the concentration of the test molecule at any point along the PK profile within a coefficient of variation of ~5%. Depletion of the analyte from the well was characterized and was determined to follow first-order rate kinetics, indicated by statistically equivalent (p > 0.05) depletion half-lives that were independent of the starting concentration. A PK curve for an approved antibiotic, levofloxacin, was generated to show utility beyond the fluorescein test molecule. PMID:26727249

  1. Validity of Intraoral Scans Compared with Plaster Models: An In-Vivo Comparison of Dental Measurements and 3D Surface Analysis

    PubMed Central

    2016-01-01

    Purpose Dental measurements have been commonly taken from plaster dental models obtained from alginate impressions can. Through the use of an intraoral scanner, digital impressions now acquire the information directly from the mouth. The purpose of this study was to determine the validity of the intraoral scans compared to plaster models. Materials and Methods Two types of dental models (intraoral scan and plaster model) of 20 subjects were included in this study. The subjects had impressions taken of their teeth and made as plaster model. In addition, their mouths were scanned with the intraoral scanner and the scans were converted into digital models. Eight transverse and 16 anteroposterior measurements, 24 tooth heights and widths were recorded on the plaster models with a digital caliper and on the intraoral scan with 3D reverse engineering software. For 3D surface analysis, the two models were superimposed by using best-fit algorithm. The average differences between the two models at all points on the surfaces were computed. Paired t-test and Bland-Altman plot were used to determine the validity of measurements from the intraoral scan compared to those from the plaster model. Results There were no significant differences between the plaster models and intraoral scans, except for one measurement of lower intermolar width. The Bland-Altman plots of all measurements showed that differences between the two models were within the limits of agreement. The average surface difference between the two models was within 0.10 mm. Conclusions The results of the present study indicate that the intraoral scans are clinically acceptable for diagnosis and treatment planning in dentistry and can be used in place of plaster models. PMID:27304976

  2. SU-E-CAMPUS-T-05: Validation of High-Resolution 3D Patient QA for Proton Pencil Beam Scanning and IMPT by Polymer Gel Dosimetry

    SciTech Connect

    Cardin, A; Avery, S; Ding, X; Kassaee, A; Lin, L; Maryanski, M

    2014-06-15

    Purpose: Validation of high-resolution 3D patient QA for proton pencil beam scanning and IMPT by polymer gel dosimetry. Methods: Four BANG3Pro polymer gel dosimeters (manufactured by MGS Research Inc, Madison, CT) were used for patient QA at the Robert's Proton Therapy Center (RPTC, Philadelphia, PA). All dosimeters were sealed in identical thin-wall Pyrex glass spheres. Each dosimeter contained a set of markers for 3D registration purposes. The dosimeters were mounted in a consistent and reproducible manner using a custom build holder. Two proton pencil beam scanning plans were designed using Varian Eclipse™ treatment planning system: 1) A two-field intensity modulated proton therapy (IMPT) plan and 2) one single field uniform dose (SFUD) plan. The IMPT fields were evaluated as a composite plan and individual fields, the SFUD plan was delivered as a single field plan.Laser CT scanning was performed using the manufacturer's OCTOPUS-IQ axial transmission laser CT scanner using a 1 mm slice thickness. 3D registration, analysis, and OD/cm to absorbed dose calibrations were perfomed using DICOM RT-Dose and CT files, and software developed by the manufacturer. 3D delta index, a metric equivalent to the gamma tool, was used for dose comparison. Results: Very good agreement with single IMPT fields and with SFUD was obtained. Composite IMPT fields had a less satisfactory agreement. The single fields had 3D delta index passing rates (3% dose difference, 3 mm DTA) of 98.98% and 94.91%. The composite 3D delta index passing rate was 80.80%. The SFUD passing rate was 93.77%. Required shifts of the dose distributions were less than 4 mm. Conclusion: A formulation of the BANG3Pro polymer gel dosimeter, suitable for 3D QA of proton patient plans is established and validated. Likewise, the mailed QA analysis service provided by the manufacturer is a practical option when required resources are unavailable. We fully disclose that the subject of this research regards a production

  3. Development of a 3D optical scanning-based automatic quality assurance system for proton range compensators

    SciTech Connect

    Kim, MinKyu; Ju, Sang Gyu E-mail: doho.choi@samsung.com; Chung, Kwangzoo; Hong, Chae-Seon; Kim, Jinsung; Ahn, Sung Hwan; Jung, Sang Hoon; Han, Youngyih; Chung, Yoonsun; Cho, Sungkoo; Choi, Doo Ho E-mail: doho.choi@samsung.com; Kim, Jungkuk; Shin, Dongho

    2015-02-15

    Purpose: A new automatic quality assurance (AutoRCQA) system using a three-dimensional scanner (3DS) with system automation was developed to improve the accuracy and efficiency of the quality assurance (QA) procedure for proton range compensators (RCs). The system performance was evaluated for clinical implementation. Methods: The AutoRCQA system consists of a three-dimensional measurement system (3DMS) based on 3DS and in-house developed verification software (3DVS). To verify the geometrical accuracy, the planned RC data (PRC), calculated with the treatment planning system (TPS), were reconstructed and coregistered with the measured RC data (MRC) based on the beam isocenter. The PRC and MRC inner surfaces were compared with composite analysis (CA) using 3DVS, using the CA pass rate for quantitative analysis. To evaluate the detection accuracy of the system, the authors designed a fake PRC by artificially adding small cubic islands with side lengths of 1.5, 2.5, and 3.5 mm on the inner surface of the PRC and performed CA with the depth difference and distance-to-agreement tolerances of [1 mm, 1 mm], [2 mm, 2 mm], and [3 mm, 3 mm]. In addition, the authors performed clinical tests using seven RCs [computerized milling machine (CMM)-RCs] manufactured by CMM, which were designed for treating various disease sites. The systematic offsets of the seven CMM-RCs were evaluated through the automatic registration function of AutoRCQA. For comparison with conventional technique, the authors measured the thickness at three points in each of the seven CMM-RCs using a manual depth measurement device and calculated thickness difference based on the TPS data (TPS-manual measurement). These results were compared with data obtained from 3DVS. The geometrical accuracy of each CMM-RC inner surface was investigated using the TPS data by performing CA with the same criteria. The authors also measured the net processing time, including the scan and analysis time. Results: The Auto

  4. 3D nanostructured inkjet printed graphene via UV-pulsed laser irradiation enables paper-based electronics and electrochemical devices.

    PubMed

    Das, Suprem R; Nian, Qiong; Cargill, Allison A; Hondred, John A; Ding, Shaowei; Saei, Mojib; Cheng, Gary J; Claussen, Jonathan C

    2016-09-21

    Emerging research on printed and flexible graphene-based electronics is beginning to show tremendous promise for a wide variety of fields including wearable sensors and thin film transistors. However, post-print annealing/reduction processes that are necessary to increase the electrical conductivity of the printed graphene degrade sensitive substrates (e.g., paper) and are whole substrate processes that are unable to selectively anneal/reduce only the printed graphene-leaving sensitive device components exposed to damaging heat or chemicals. Herein a pulsed laser process is introduced that can selectively irradiate inkjet printed reduced graphene oxide (RGO) and subsequently improve the electrical conductivity (Rsheet∼0.7 kΩ□(-1)) of printed graphene above previously published reports. Furthermore, the laser process is capable of developing 3D petal-like graphene nanostructures from 2D planar printed graphene. These visible morphological changes display favorable electrochemical sensing characteristics-ferricyanide cyclic voltammetry with a redox peak separation (ΔEp) ≈ 0.7 V as well as hydrogen peroxide (H2O2) amperometry with a sensitivity of 3.32 μA mM(-1) and a response time of <5 s. Thus this work paves the way for not only paper-based electronics with graphene circuits, it enables the creation of low-cost and disposable graphene-based electrochemical electrodes for myriad applications including sensors, biosensors, fuel cells, and theranostic devices.

  5. A Comprehensive Automated 3D Approach for Building Extraction, Reconstruction, and Regularization from Airborne Laser Scanning Point Clouds

    PubMed Central

    Dorninger, Peter; Pfeifer, Norbert

    2008-01-01

    Three dimensional city models are necessary for supporting numerous management applications. For the determination of city models for visualization purposes, several standardized workflows do exist. They are either based on photogrammetry or on LiDAR or on a combination of both data acquisition techniques. However, the automated determination of reliable and highly accurate city models is still a challenging task, requiring a workflow comprising several processing steps. The most relevant are building detection, building outline generation, building modeling, and finally, building quality analysis. Commercial software tools for building modeling require, generally, a high degree of human interaction and most automated approaches described in literature stress the steps of such a workflow individually. In this article, we propose a comprehensive approach for automated determination of 3D city models from airborne acquired point cloud data. It is based on the assumption that individual buildings can be modeled properly by a composition of a set of planar faces. Hence, it is based on a reliable 3D segmentation algorithm, detecting planar faces in a point cloud. This segmentation is of crucial importance for the outline detection and for the modeling approach. We describe the theoretical background, the segmentation algorithm, the outline detection, and the modeling approach, and we present and discuss several actual projects. PMID:27873931

  6. A Comprehensive Automated 3D Approach for Building Extraction, Reconstruction, and Regularization from Airborne Laser Scanning Point Clouds.

    PubMed

    Dorninger, Peter; Pfeifer, Norbert

    2008-11-17

    Three dimensional city models are necessary for supporting numerous management applications. For the determination of city models for visualization purposes, several standardized workflows do exist. They are either based on photogrammetry or on LiDAR or on a combination of both data acquisition techniques. However, the automated determination of reliable and highly accurate city models is still a challenging task, requiring a workflow comprising several processing steps. The most relevant are building detection, building outline generation, building modeling, and finally, building quality analysis. Commercial software tools for building modeling require, generally, a high degree of human interaction and most automated approaches described in literature stress the steps of such a workflow individually. In this article, we propose a comprehensive approach for automated determination of 3D city models from airborne acquired point cloud data. It is based on the assumption that individual buildings can be modeled properly by a composition of a set of planar faces. Hence, it is based on a reliable 3D segmentation algorithm, detecting planar faces in a point cloud. This segmentation is of crucial importance for the outline detection and for the modeling approach. We describe the theoretical background, the segmentation algorithm, the outline detection, and the modeling approach, and we present and discuss several actual projects.

  7. Guided wave-based J-integral estimation for dynamic stress intensity factors using 3D scanning laser Doppler vibrometry

    NASA Astrophysics Data System (ADS)

    Ayers, J.; Owens, C. T.; Liu, K. C.; Swenson, E.; Ghoshal, A.; Weiss, V.

    2013-01-01

    The application of guided waves to interrogate remote areas of structural components has been researched extensively in characterizing damage. However, there exists a sparsity of work in using piezoelectric transducer-generated guided waves as a method of assessing stress intensity factors (SIF). This quantitative information enables accurate estimation of the remaining life of metallic structures exhibiting cracks, such as military and commercial transport vehicles. The proposed full wavefield approach, based on 3D laser vibrometry and piezoelectric transducer-generated guided waves, provides a practical means for estimation of dynamic stress intensity factors (DSIF) through local strain energy mapping via the J-integral. Strain energies and traction vectors can be conveniently estimated from wavefield data recorded using 3D laser vibrometry, through interpolation and subsequent spatial differentiation of the response field. Upon estimation of the Jintegral, it is possible to obtain the corresponding DSIF terms. For this study, the experimental test matrix consists of aluminum plates with manufactured defects representing canonical elliptical crack geometries under uniaxial tension that are excited by surface mounted piezoelectric actuators. The defects' major to minor axes ratios vary from unity to approximately 133. Finite element simulations are compared to experimental results and the relative magnitudes of the J-integrals are examined.

  8. Simplification of 3D Graphics for Mobile Devices: Exploring the Trade-off Between Energy Savings and User Perceptions of Visual Quality

    NASA Astrophysics Data System (ADS)

    Vatjus-Anttila, Jarkko; Koskela, Timo; Lappalainen, Tuomas; Häkkilä, Jonna

    2017-03-01

    3D graphics have quickly become a popular form of media that can also be accessed with today's mobile devices. However, the use of 3D applications with mobile devices is typically a very energy-consuming task due to the processing complexity and the large file size of 3D graphics. As a result, their use may lead to rapid depletion of the limited battery life. In this paper, we investigate how much energy savings can be gained in the transmission and rendering of 3D graphics by simplifying geometry data. In this connection, we also examine users' perceptions on the visual quality of the simplified 3D models. The results of this paper provide new knowledge on the energy savings that can be gained through geometry simplification, as well as on how much the geometry can be simplified before the visual quality of 3D models becomes unacceptable for the mobile users. Based on the results, it can be concluded that geometry simplification can provide significant energy savings for mobile devices without disturbing the users. When geometry simplification is combined with distance based adjustment of detail, up to 52% energy savings were gained in our experiments compared to using only a single high quality 3D model.

  9. 3D-Printed Fluidic Devices for Nanoparticle Preparation and Flow-Injection Amperometry Using Integrated Prussian Blue Nanoparticle-Modified Electrodes.

    PubMed

    Bishop, Gregory W; Satterwhite, Jennifer E; Bhakta, Snehasis; Kadimisetty, Karteek; Gillette, Kelsey M; Chen, Eric; Rusling, James F

    2015-01-01

    A consumer-grade fused filament fabrication (FFF) 3D printer was used to construct fluidic devices for nanoparticle preparation and electrochemical sensing. Devices were printed using poly(ethylene terephthalate) and featured threaded ports to connect polyetheretherketone (PEEK) tubing via printed fittings prepared from acrylonitrile butadiene styrene (ABS). These devices included channels designed to have 800 μm × 800 μm square cross sections and were semitransparent to allow visualization of the solution-filled channels. A 3D-printed device with a Y-shaped mixing channel was used to prepare Prussian blue nanoparticles (PBNPs) under flow rates of 100 to 2000 μL min(-1). PBNPs were then attached to gold electrodes for hydrogen peroxide sensing. 3D-printed devices used for electrochemical measurements featured threaded access ports into which a fitting equipped with reference, counter, and PBNP-modified working electrodes could be inserted. PBNP-modified electrodes enabled amperometric detection of H2O2 in the 3D-printed channel by flow-injection analysis, exhibiting a detection limit of 100 nM and linear response up to 20 μM. These experiments show that a consumer-grade FFF printer can be used to fabricate low-cost fluidic devices for applications similar to those that have been reported with more expensive 3D-printing methods.

  10. 3D-Printed Fluidic Devices for Nanoparticle Preparation and Flow-Injection Amperometry Using Integrated Prussian Blue Nanoparticle-Modified Electrodes

    PubMed Central

    Bishop, Gregory W.; Satterwhite, Jennifer E.; Bhakta, Snehasis; Kadimisetty, Karteek; Gillette, Kelsey M.; Chen, Eric; Rusling, James F.

    2015-01-01

    A consumer-grade fused filament fabrication (FFF) 3D printer was used to construct fluidic devices for nanoparticle preparation and electrochemical sensing. Devices were printed using poly(ethylene terephthalate) and featured threaded ports to connect polyetheretherketone (PEEK) tubing via printed fittings prepared from acrylonitrile butadiene styrene (ABS). These devices included channels designed to have 800 × 800 µm2 square cross sections and were semitransparent to allow visualization of the solution-filled channels. A 3D-printed device with a Y-shaped mixing channel was used to prepare Prussian blue nanoparticles (PBNPs) under flow rates of 100 to 2000 µL min−1. PBNPs were then attached to gold electrodes for hydrogen peroxide sensing. 3D-printed devices used for electrochemical measurements featured threaded access ports into which a fitting equipped with reference, counter, and PBNP-modified working electrodes could be inserted. PBNP-modified electrodes enabled amperometric detection of H2O2 in the 3D-printed channel by flow-injection analysis, exhibiting a detection limit of 100 nM and linear response up to 20 µM. These experiments show that a consumer-grade FFF printer can be used to fabricate low-cost fluidic devices for applications similar to those that have been reported with more expensive 3D-printing methods. PMID:25901660

  11. Technical note: Criterion validity of whole body surface area equations: a comparison using 3D laser scanning.

    PubMed

    Daniell, Nathan; Olds, Timothy; Tomkinson, Grant

    2012-05-01

    Measurements of whole body surface area (WBSA) have important applications in numerous fields including biological anthropology, clinical medicine, biomechanics, and sports science. Currently, WBSA is most often estimated using predictive equations due to the complex and time consuming methods required for direct measurement. The main aim of this study was to identify whether there were significant and meaningful differences between WBSA measurements taken using a whole body three-dimensional (3D) scanner (criterion measure) and the estimates derived from each WBSA equation identified from a systematic review. The study also aimed to determine whether differences varied according to body mass index (BMI), sex, or athletic status. Fifteen WBSA equations were compared with direct measurements taken on 1,714 young adult subjects, aged 18-30 years, using the Vitus Smart 3D whole body scanner, including 1,452 subjects (753 males, 699 females) from the general Australian population and 262 rowers (148 males, 114 females). Mixed-design analysis of variances determined significant differences and accuracy was quantified using Bland-Altman analysis and effect sizes. Thirteen of the 15 equations overestimated WBSA. With a few exceptions, equations were accurate with a low-systematic error (bias ≤2%) and low-random error (standard deviation of the differences 1.5-3.0%). However, BMI did have a substantial impact with the accuracy of some WBSA equations varying between the four BMI categories. The Shuter and Aslani: Eur J Appl Physiol 82 (2000) 250-254 equation was identified as the most accurate equation and should be used for Western populations 18-30 years of age. Care must be taken when deciding which equation to use when estimating WBSA.

  12. Computer-aided diagnosis: a 3D segmentation method for lung nodules in CT images by use of a spiral-scanning technique

    NASA Astrophysics Data System (ADS)

    Wang, Jiahui; Engelmann, Roger; Li, Qiang

    2008-03-01

    Lung nodule segmentation in computed tomography (CT) plays an important role in computer-aided detection, diagnosis, and quantification systems for lung cancer. In this study, we developed a simple but accurate nodule segmentation method in three-dimensional (3D) CT. First, a volume of interest (VOI) was determined at the location of a nodule. We then transformed the VOI into a two-dimensional (2D) image by use of a "spiral-scanning" technique, in which a radial line originating from the center of the VOI spirally scanned the VOI. The voxels scanned by the radial line were arranged sequentially to form a transformed 2D image. Because the surface of a nodule in 3D image became a curve in the transformed 2D image, the spiral-scanning technique considerably simplified our segmentation method and enabled us to obtain accurate segmentation results. We employed a dynamic programming technique to delineate the "optimal" outline of a nodule in the 2D image, which was transformed back into the 3D image space to provide the interior of the nodule. The proposed segmentation method was trained on the first and was tested on the second Lung Image Database Consortium (LIDC) datasets. An overlap between nodule regions provided by computer and by the radiologists was employed as a performance metric. The experimental results on the LIDC database demonstrated that our segmentation method provided relatively robust and accurate segmentation results with mean overlap values of 66% and 64% for the nodules in the first and second LIDC datasets, respectively, and would be useful for the quantification, detection, and diagnosis of lung cancer.

  13. Noise Analysis on Graphene Devices via Scanning Noise Microscopy

    NASA Astrophysics Data System (ADS)

    Cho, Duckhyung; Sung, Moon Gyu; Lee, Hyungwoo; Heo, Kwang; Byun, Kyung-Eun; Kim, Taekyeong; Seo, David H.; Seo, Sunae; Hong, Seunghun

    2013-03-01

    Until now, the studies about low-frequency noises in electronic devices have mostly relied on the scaling behaviour analysis of current noise measured from multiple devices with different resistance values. However, the fabrication of such multiple devices for noise analysis is a labor-intensive and time-consuming work. Herein, we developed the scanning noise microscopy (SNM) method for nanoscale noise analysis of electronic devices, which allowed us to measure the scaling behaviour of electrical current noises in a graphene-strip-based device. In this method, a conductive atomic force microscopy probe made a direct contact on the graphene strip channel in the device to measure the noise spectra through it. The SNM method enabled the investigation of the noise scaling behaviour using only a single device. In addition, the nanoscale noise map was obtained, which allowed us to study the effect of structural defects on the noise characteristics of the graphene strip channel. Our method should be a powerful strategy for nanoscale noise analysis and play a significant role in basic research on nanoscale devices.

  14. 3D printing of soft lithography mold for rapid production of polydimethylsiloxane-based microfluidic devices for cell stimulation with concentration gradients.

    PubMed

    Kamei, Ken-ichiro; Mashimo, Yasumasa; Koyama, Yoshie; Fockenberg, Christopher; Nakashima, Miyuki; Nakajima, Minako; Li, Junjun; Chen, Yong

    2015-04-01

    Three-dimensional (3D) printing is advantageous over conventional technologies for the fabrication of sophisticated structures such as 3D micro-channels for future applications in tissue engineering and drug screening. We aimed to apply this technology to cell-based assays using polydimethylsiloxane (PDMS), the most commonly used material for fabrication of micro-channels used for cell culture experiments. Useful properties of PDMS include biocompatibility, gas permeability and transparency. We developed a simple and robust protocol to generate PDMS-based devices using a soft lithography mold produced by 3D printing. 3D chemical gradients were then generated to stimulate cells confined to a micro-channel. We demonstrate that concentration gradients of growth factors, important regulators of cell/tissue functions in vivo, influence the survival and growth of human embryonic stem cells. Thus, this approach for generation of 3D concentration gradients could have strong implications for tissue engineering and drug screening.

  15. Transmissive liquid-crystal device correcting primary coma aberration and astigmatism in laser scanning microscopy

    NASA Astrophysics Data System (ADS)

    Tanabe, Ayano; Hibi, Terumasa; Ipponjima, Sari; Matsumoto, Kenji; Yokoyama, Masafumi; Kurihara, Makoto; Hashimoto, Nobuyuki; Nemoto, Tomomi

    2016-03-01

    Laser scanning microscopy allows 3D cross-sectional imaging inside biospecimens. However, certain aberrations produced can degrade the quality of the resulting images. We previously reported a transmissive liquid-crystal device that could compensate for the predominant spherical aberrations during the observations, particularly in deep regions of the samples. The device, inserted between the objective lens and the microscope revolver, improved the image quality of fixed-mouse-brain slices that were observed using two-photon excitation laser scanning microscopy, which was originally degraded by spherical aberration. In this study, we developed a transmissive device that corrects primary coma aberration and astigmatism, motivated by the fact that these asymmetric aberrations can also often considerably deteriorate image quality, even near the sample surface. The device's performance was evaluated by observing fluorescent beads using single-photon excitation laser scanning microscopy. The fluorescence intensity in the image of the bead under a cover slip tilted in the y-direction was increased by 1.5 times after correction by the device. Furthermore, the y- and z-widths of the imaged bead were reduced to 66% and 65%, respectively. On the other hand, for the imaged bead sucked into a glass capillary in the longitudinal x-direction, correction with the device increased the fluorescence intensity by 2.2 times compared to that of the aberrated image. In addition, the x-, y-, and z-widths of the bead image were reduced to 75%, 53%, and 40%, respectively. Our device successfully corrected several asymmetric aberrations to improve the fluorescent signal and spatial resolution, and might be useful for observing various biospecimens.

  16. Standing-wave-excited multiplanar fluorescence in a laser scanning microscope reveals 3D information on red blood cells.

    PubMed

    Amor, Rumelo; Mahajan, Sumeet; Amos, William Bradshaw; McConnell, Gail

    2014-12-08

    Standing-wave excitation of fluorescence is highly desirable in optical microscopy because it improves the axial resolution. We demonstrate here that multiplanar excitation of fluorescence by a standing wave can be produced in a single-spot laser scanning microscope by placing a plane reflector close to the specimen. We report here a variation in the intensity of fluorescence of successive planes related to the Stokes shift of the dye. We show by the use of dyes specific for the cell membrane how standing-wave excitation can be exploited to generate precise contour maps of the surface membrane of red blood cells, with an axial resolution of ≈90 nm. The method, which requires only the addition of a plane mirror to an existing confocal laser scanning microscope, may well prove useful in studying diseases which involve the red cell membrane, such as malaria.

  17. Standing-wave-excited multiplanar fluorescence in a laser scanning microscope reveals 3D information on red blood cells

    NASA Astrophysics Data System (ADS)

    Amor, Rumelo; Mahajan, Sumeet; Amos, William Bradshaw; McConnell, Gail

    2014-12-01

    Standing-wave excitation of fluorescence is highly desirable in optical microscopy because it improves the axial resolution. We demonstrate here that multiplanar excitation of fluorescence by a standing wave can be produced in a single-spot laser scanning microscope by placing a plane reflector close to the specimen. We report here a variation in the intensity of fluorescence of successive planes related to the Stokes shift of the dye. We show by the use of dyes specific for the cell membrane how standing-wave excitation can be exploited to generate precise contour maps of the surface membrane of red blood cells, with an axial resolution of ~90 nm. The method, which requires only the addition of a plane mirror to an existing confocal laser scanning microscope, may well prove useful in studying diseases which involve the red cell membrane, such as malaria.

  18. Documenting a Complex Modern Heritage Building Using Multi Image Close Range Photogrammetry and 3d Laser Scanned Point Clouds

    NASA Astrophysics Data System (ADS)

    Vianna Baptista, M. L.

    2013-07-01

    Integrating different technologies and expertises help fill gaps when optimizing documentation of complex buildings. Described below is the process used in the first part of a restoration project, the architectural survey of Theatre Guaira Cultural Centre in Curitiba, Brazil. To diminish time on fieldwork, the two-person-field-survey team had to juggle, during three days, the continuous artistic activities and performers' intense schedule. Both technologies (high definition laser scanning and close-range photogrammetry) were used to record all details in the least amount of time without disturbing the artists' rehearsals and performances. Laser Scanning was ideal to record the monumental stage structure with all of its existing platforms, light fixtures, scenery walls and curtains. Although scanned with high-definition, parts of the exterior façades were also recorded using Close Range Photogrammetry. Tiny cracks on the marble plaques and mosaic tiles, not visible in the point clouds, were then able to be precisely documented in order to create the exterior façades textures and damages mapping drawings. The combination of technologies and the expertise of service providers, knowing how and what to document, and what to deliver to the client, enabled maximum benefits to the following restoration project.

  19. Characterization of 3D Trench PZT Capacitors for High Density FRAM Devices by Synchrotron X-ray Micro-diffraction

    SciTech Connect

    Shin, Sangmin; Park, Youngsoo; Han, Hee; Park, Yong Jun; Baik, Sunggi; Choi, Jae-Young

    2007-01-19

    3D trench PbZrxTi1-xO3 (PZT) capacitors for 256 Mbit 1T-1C FRAM devices were characterized by synchrotron X-ray micro-diffraction at Pohang Light Source. Three layers, Ir/PZT/Ir were deposited on SiO2 trench holes with different widths ranging from 180 nm to 810 nm and 400 nm in depth by ALD and MOCVD. Each hole is separated from neighboring holes by 200 nm. The cross sectional TEM analysis for the trenches revealed that the PZT layers were consisted of columnar grains at the trench entrance and changes to polycrystalline granular grains at the lower part of the trench. The transition from columnar to granular grains was dependent on the trench size. The smaller trenches were favorable to granular grain formation. High resolution synchrotron X-ray diffraction analysis was performed to determine the crystal structure of each region. The beam was focused to about 500 {mu}m and the diffraction patterns were obtained from a single trench. Only the peaks corresponding to ferroelectric tetragonal phases are observed for the trenches larger than 670 nm, which consist of fully columnar grains. However, the trenches smaller than 670 nm showed the peaks corresponding the pyrochlore phases, which suggested that the granular grains are of pyrochlore phases and non-ferroelectric.

  20. A 3D-printed device for a smartphone-based chemiluminescence biosensor for lactate in oral fluid and sweat.

    PubMed

    Roda, Aldo; Guardigli, Massimo; Calabria, Donato; Calabretta, Maria Maddalena; Cevenini, Luca; Michelini, Elisa

    2014-12-21

    Increasingly, smartphones are used as portable personal computers, revolutionizing communication styles and entire lifestyles. Using 3D-printing technology we have made a disposable minicartridge that can be easily prototyped to turn any kind of smartphone or tablet into a portable luminometer to detect chemiluminescence derived from enzyme-coupled reactions. As proof-of-principle, lactate oxidase was coupled with horseradish peroxidase for lactate determination in oral fluid and sweat. Lactate can be quantified in less than five minutes with detection limits of 0.5 mmol L(-1) (corresponding to 4.5 mg dL(-1)) and 0.1 mmol L(-1) (corresponding to 0.9 mg dL(-1)) in oral fluid and sweat, respectively. A smartphone-based device shows adequate analytical performance to offer a cost-effective alternative for non-invasive lactate measurement. It could be used to evaluate lactate variation in relation to the anaerobic threshold in endurance sport and for monitoring lactic acidosis in critical-care patients.

  1. An approach for the calibration of a combined RGB-sensor and 3D-camera device

    NASA Astrophysics Data System (ADS)

    Schulze, M.

    2011-07-01

    The elds of application for 3d cameras are very dierent, because high image frequency and determination of 3d data. Often, 3d cameras are used for mobile robotic. They are used for obstacle detection or object recognition. So they also are interesting for applications in agriculture, in combination with mobile robots. Here, in addition to 3d data, there is often a necessity to get color information for each 3d point. Unfortunately, 3d cameras do not capture any color information. Therefore, an additional sensor is necessary, such as RGB plus possibly NIR. To combine data of two dierent sensors a reference to each other, via calibration, is important. This paper presents several calibration methods and discuss their accuracy potential. Based on a spatial resection, the algorithm determines the translation and rotation between the two sensors and the inner orientation of the used sensor.

  2. Quantification of the postural and technical errors in asymptomatic adults using direct 3D whole body scan measurements of standing posture.

    PubMed

    Tomkinson, Grant R; Shaw, Linda G

    2013-02-01

    Measurement repeatability has important decision-making implications for clinicians and researchers when assessing individuals. The aims of this study were to quantify: (a) the repeatability of direct measurements of standing posture using three dimensional (3D) whole body scanning, and (b) the magnitude of the postural and technical errors involved. Fifty-two asymptomatic adults were scanned twice, 24h apart, using the Vitus Smart 3D whole body scanner. Eleven clinically relevant standing postural measurements were calculated from scan-extracted data. The process was repeated with 10 shop mannequins. Systematic error was expressed as absolute changes in means and as standardised effect sizes, with random (within-subject) error expressed as the typical error. Technical error was calculated as the typical error in the measurement of mannequins; total error as the typical error in the measurement of subjects; and postural error as the square root of the difference between the squared total error and the squared technical error. Most standing postural measurements demonstrated good repeatability, with median (95% CI) systematic and random errors of -0.1° (1.1°) and 2.8° (1.9°), respectively. However, head and neck postures demonstrated poor repeatability due to large random errors brought about by large postural errors. Overall, most of the error was due to postural error rather than technical error. The relatively small technical errors highlight that this 3D measurement process is generally repeatable, while the relatively large postural errors related to the head and neck suggest that these postures probably lack the precision to be clinically useful using this procedure.

  3. Stroboscobic near-field scanning optical microscopy for 3D mapping of mode profiles of plasmonic nanostructures (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Dana, Aykutlu; Ozgur, Erol; Torunoglu, Gamze

    2016-09-01

    We present a dynamic approach to scanning near field optical microscopy that extends the measurement technique to the third dimension, by strobing the illumination in sync with the cantilever oscillation. Nitrogen vacancy (NV) centers in nanodiamonds placed on cantilever tips are used as stable emitters for emission enhancement. Local field enhancement and modulation of optical density states are mapped in three dimensions based on fluorescence intensity and spectrum changes as the tip is scanned over plasmonic nanostructures. The excitation of NV centers is done using a total internal reflection setup. Using a digital phase locked loop to pulse the excitation in various tip sample separations, 2D slices of fluorescence enhancement can be recorded. Alternatively, a conventional SNOM tip can be used to selectively couple wideband excitation to the collection path, with subdiffraction resolution of 60 nm in x and y and 10 nm in z directions. The approach solves the problem of tip-sample separation stabilization over extended periods of measurement time, required to collect data resolved in emission wavelength and three spatial dimensions. The method can provide a unique way of accessing the three dimensional field and mode profiles of nanophotonics structures.

  4. A scalable diffraction-based scanning 3D colour video display as demonstrated by using tiled gratings and a vertical diffuser

    PubMed Central

    Jia, Jia; Chen, Jhensi; Yao, Jun; Chu, Daping

    2017-01-01

    A high quality 3D display requires a high amount of optical information throughput, which needs an appropriate mechanism to distribute information in space uniformly and efficiently. This study proposes a front-viewing system which is capable of managing the required amount of information efficiently from a high bandwidth source and projecting 3D images with a decent size and a large viewing angle at video rate in full colour. It employs variable gratings to support a high bandwidth distribution. This concept is scalable and the system can be made compact in size. A horizontal parallax only (HPO) proof-of-concept system is demonstrated by projecting holographic images from a digital micro mirror device (DMD) through rotational tiled gratings before they are realised on a vertical diffuser for front-viewing. PMID:28304371

  5. A scalable diffraction-based scanning 3D colour video display as demonstrated by using tiled gratings and a vertical diffuser

    NASA Astrophysics Data System (ADS)

    Jia, Jia; Chen, Jhensi; Yao, Jun; Chu, Daping

    2017-03-01

    A high quality 3D display requires a high amount of optical information throughput, which needs an appropriate mechanism to distribute information in space uniformly and efficiently. This study proposes a front-viewing system which is capable of managing the required amount of information efficiently from a high bandwidth source and projecting 3D images with a decent size and a large viewing angle at video rate in full colour. It employs variable gratings to support a high bandwidth distribution. This concept is scalable and the system can be made compact in size. A horizontal parallax only (HPO) proof-of-concept system is demonstrated by projecting holographic images from a digital micro mirror device (DMD) through rotational tiled gratings before they are realised on a vertical diffuser for front-viewing.

  6. Investigations on 2D and 3D topography and Z-scan studies of zinc chloride co-doped L-lysinium succinate

    NASA Astrophysics Data System (ADS)

    Kalaivani, D.; Jayaraman, D.; Joseph, V.

    2015-10-01

    Semi-organic NLO single crystals of zinc chloride doped L-lysinium succinate (ZnCl2-Lls) were grown using a slow evaporation method at ambient temperature. The structure and cell parameters of the grown crystal were determined by single crystal XRD and powder XRD studies. The 2-D surface morphology and elemental compositions were analyzed through SEM and EDAX studies. The 3-D surface topology was discussed using AFM images. Z-scan technique was used for measuring the third order nonlinear optical coefficients of the grown crystal.

  7. 3D imaging of cement-based materials at submicron resolution by combining laser scanning confocal microscopy with serial sectioning.

    PubMed

    Yio, M H N; Mac, M J; Wong, H S; Buenfeld, N R

    2015-05-01

    In this paper, we present a new method to reconstruct large volumes of nontransparent porous materials at submicron resolution. The proposed method combines fluorescence laser scanning confocal microscopy with serial sectioning to produce a series of overlapping confocal z-stacks, which are then aligned and stitched based on phase correlation. The method can be extended in the XY plane to further increase the overall image volume. Resolution of the reconstructed image volume does not degrade with increase in sample size. We have used the method to image cementitious materials, hardened cement paste and concrete and the results obtained show that the method is reliable. Possible applications of the method such as three-dimensional characterization of the pores and microcracks in hardened concrete, three-dimensional particle shape characterization of cementitious materials and three-dimensional characterization of other porous materials such as rocks and bioceramics are discussed.

  8. Three-dimensional scanning near field optical microscopy (3D-SNOM) imaging of random arrays of copper nanoparticles: implications for plasmonic solar cell enhancement.

    PubMed

    Ezugwu, Sabastine; Ye, Hanyang; Fanchini, Giovanni

    2015-01-07

    In order to investigate the suitability of random arrays of nanoparticles for plasmonic enhancement in the visible-near infrared range, we introduced three-dimensional scanning near-field optical microscopy (3D-SNOM) imaging as a useful technique to probe the intensity of near-field radiation scattered by random systems of nanoparticles at heights up to several hundred nm from their surface. We demonstrated our technique using random arrays of copper nanoparticles (Cu-NPs) at different particle diameter and concentration. Bright regions in the 3D-SNOM images, corresponding to constructive interference of forward-scattered plasmonic waves, were obtained at heights Δz ≥ 220 nm from the surface for random arrays of Cu-NPs of ∼ 60-100 nm in diameter. These heights are too large to use Cu-NPs in contact of the active layer for light harvesting in thin organic solar cells, which are typically no thicker than 200 nm. Using a 200 nm transparent spacer between the system of Cu-NPs and the solar cell active layer, we demonstrate that forward-scattered light can be conveyed in 200 nm thin film solar cells. This architecture increases the solar cell photoconversion efficiency by a factor of 3. Our 3D-SNOM technique is general enough to be suitable for a large number of other applications in nanoplasmonics.

  9. Advanced human carotid plaque progression correlates positively with flow shear stress using follow-up scan data: an in vivo MRI multi-patient 3D FSI study.

    PubMed

    Yang, Chun; Canton, Gador; Yuan, Chun; Ferguson, Marina; Hatsukami, Thomas S; Tang, Dalin

    2010-09-17

    Although it has been well-accepted that atherosclerosis initiation and early progression correlate negatively with flow wall shear stresses (FSS), increasing evidence suggests mechanisms governing advanced plaque progression are not well understood. Fourteen patients were scanned 2-4 times at 18 month intervals using a histologically validated multi-contrast magnetic resonance imaging (MRI) protocol to acquire carotid plaque progression data. Thirty-two scan pairs (baseline and follow-up scans) were formed with slices matched for model construction and analysis. 3D fluid-structure interaction (FSI) models were constructed and plaque wall stress (PWS) and flow shear stress (FSS) were obtained from all matching lumen data points (400-1000 per plaque; 100 points per matched slice) to quantify correlations with plaque progression measured by vessel wall thickness increase (WTI). Using FSS and PWS data from follow-up scan, 21 out of 32 scan pairs showed a significant positive correlation between WTI and FSS (positive/negative/no significance ratio=21/8/3), and 26 out of 32 scan pairs showed a significant negative correlation between WTI and PWS (positive/negative/no significance ratio=2/26/4). The mean FSS value of lipid core nodes (n=5294) from all 47 plaque models was 63.5dyn/cm(2), which was 45% higher than that from all normal vessel nodes (n=27553, p<0.00001). The results from this intensive FSI study indicate that flow shear stress from follow-up scan correlates positively with advanced plaque progression which is different from what has been observed in plaque initiation and early-stage progression. It should be noted that the correlation results do not automatically lead to any causality conclusions.

  10. Contrast Enhancement of MicroCT Scans to Aid 3D Modelling of Carbon Fibre Fabric Composites

    NASA Astrophysics Data System (ADS)

    Djukic, Luke P.; Pearce, Garth M.; Herszberg, Israel; Bannister, Michael K.; Mollenhauer, David H.

    2013-12-01

    This paper presents a methodology for volume capture and rendering of plain weave and multi-layer fabric meso-architectures within a consolidated, cured laminate. Micro X-ray Computed Tomography (MicroCT) is an excellent tool for the non-destructive visualisation of material microstructures however the contrast between tows and resin is poor for carbon fibre composites. Firstly, this paper demonstrates techniques to improve the contrast of the microCT images by introducing higher density materials such as gold, iodine and glass into the fabric. Two approaches were demonstrated to be effective for enhancing the differentiation between the tows in the reconstructed microCT visualisations. Secondly, a method of generating three-dimensional volume models of woven composites using microCT scan data is discussed. The process of generating a model is explained from initial manufacture with the aid of an example plain weave fabric. These methods are to be used in the finite element modelling of three-dimensional fabric preforms in future work.

  11. High-Resolution 3D Imaging and Quantification of Gold Nanoparticles in a Whole Cell Using Scanning Transmission Ion Microscopy

    PubMed Central

    Chen, Xiao; Chen, Ce-Belle; Udalagama, Chammika N.B.; Ren, Minqin; Fong, Kah Ee; Yung, Lin Yue Lanry; Giorgia, Pastorin; Bettiol, Andrew Anthony; Watt, Frank

    2013-01-01

    Increasing interest in the use of nanoparticles (NPs) to elucidate the function of nanometer-sized assemblies of macromolecules and organelles within cells, and to develop biomedical applications such as drug delivery, labeling, diagnostic sensing, and heat treatment of cancer cells has prompted investigations into novel techniques that can image NPs within whole cells and tissue at high resolution. Using fast ions focused to nanodimensions, we show that gold NPs (AuNPs) inside whole cells can be imaged at high resolution, and the precise location of the particles and the number of particles can be quantified. High-resolution density information of the cell can be generated using scanning transmission ion microscopy, enhanced contrast for AuNPs can be achieved using forward scattering transmission ion microscopy, and depth information can be generated from elastically backscattered ions (Rutherford backscattering spectrometry). These techniques and associated instrumentation are at an early stage of technical development, but we believe there are no physical constraints that will prevent whole-cell three-dimensional imaging at <10 nm resolution. PMID:23561518

  12. 3D Imaging of Porous Media Using Laser Scanning Confocal Microscopy with Application to Microscale Transport Processes

    SciTech Connect

    Fredrich, J.T.

    1999-02-10

    We present advances in the application of laser scanning confocal microscopy (LSCM) to image, reconstruct, and characterize statistically the microgeometry of porous geologic and engineering materials. We discuss technical and practical aspects of this imaging technique, including both its advantages and limitations. Confocal imaging can be used to optically section a material, with sub-micron resolution possible in the lateral and axial planes. The resultant volumetric image data, consisting of fluorescence intensities for typically {approximately}50 million voxels in XYZ space, can be used to reconstruct the three-dimensional structure of the two-phase medium. We present several examples of this application, including studying pore geometry in sandstone, characterizing brittle failure processes in low-porosity rock deformed under triaxial loading conditions in the laboratory, and analyzing the microstructure of porous ceramic insulations. We then describe approaches to extract statistical microgeometric descriptions from volumetric image data, and present results derived from confocal volumetric data sets. Finally, we develop the use of confocal image data to automatically generate a three-dimensional mesh for numerical pore-scale flow simulations.

  13. Real-Time Display Of 3-D Computed Holograms By Scanning The Image Of An Acousto-Optic Modulator

    NASA Astrophysics Data System (ADS)

    Kollin, Joel S.; Benton, Stephen A.; Jepsen, Mary Lou

    1989-10-01

    The invention of holography has sparked hopes for a three-dimensional electronic imaging systems analogous to television. Unfortunately, the extraordinary spatial detail of ordinary holographic recordings requires unattainable bandwidth and display resolution for three-dimensional moving imagery, effectively preventing their commercial development. However, the essential bandwidth of holographic images can be reduced enough to permit their transmission through fiber optic or coaxial cable, and the required resolution or space-bandwidth product of the display can be obtained by raster scanning the image of a commercially available acousto-optic modulator. No film recording or other photographic intermediate step is necessary as the projected modulator image is viewed directly. The design and construction of a working demonstration of the principles involved is also presented along with a discussion of engineering considerations in the system design. Finally, the theoretical and practical limitations of the system are addressed in the context of extending the system to real-time transmission of moving holograms synthesized from views of real and computer-generated three-dimensional scenes.

  14. Computer-aided mesenteric small vessel segmentation on high-resolution 3D contrast-enhanced CT angiography scans

    NASA Astrophysics Data System (ADS)

    Zhang, Weidong; Liu, Jiamin; Yao, Jianhua; Nguyen, Tan; Louie, Adeline; Wank, Stephen; Summers, Ronald M.

    2012-03-01

    Segmentation of the mesenteric vasculature has important applications for evaluation of the small bowel. In particular, it may be useful for small bowel path reconstruction and precise localization of small bowel tumors such as carcinoid. Segmentation of the mesenteric vasculature is very challenging, even for manual labeling, because of the low contrast and tortuosity of the small blood vessels. Many vessel segmentation methods have been proposed. However, most of them are designed for segmenting large vessels. We propose a semi-automated method to extract the mesenteric vasculature on contrast-enhanced abdominal CT scans. First, the internal abdominal region of the body is automatically identified. Second, the major vascular branches are segmented using a multi-linear vessel tracing method. Third, small mesenteric vessels are segmented using multi-view multi-scale vesselness enhancement filters. The method is insensitive to image contrast, variations of vessel shape and small occlusions due to overlapping. The method could automatically detect mesenteric vessels with diameters as small as 1 mm. Compared with the standard-of-reference manually labeled by an expert radiologist, the segmentation accuracy (recall rate) for the whole mesenteric vasculature was 82.3% with a 3.6% false positive rate.

  15. Bioconjugation of peptides using advanced nanomaterials to examine their interactions in 3D printed flow-through device.

    PubMed

    Michalek, Petr; Richtera, Lukas; Krejcova, Ludmila; Nejdl, Lukas; Kensova, Renata; Zitka, Jan; Kopel, Pavel; Heger, Zbynek; Adam, Vojtech; Kizek, Rene

    2016-02-01

    Peptide-peptide interactions are crucial in the living cell as they lead to the formation of the numerous types of complexes. In this study, synthetic peptides containing 11 of cysteines (α-domain of metallothionein (MT)) and sialic acid binding region (130-loop of hemagglutinin (HA)) were employed. The aim of the experiment was studying the interactions between MT and HA-derived peptides. For this purpose, fragments were tagged with cysteines at C-terminal part to serve as ligand sites for PbS and CuS quantum dots (QDs), and therefore these conjugates can be traced and quantified during wide spectrum of methods. As a platform for interaction, γ-Fe2O3 paramagnetic particles modified with tetraethyl orthosilicate and (3-aminopropyl)triethoxysilane (hydrodynamic diameter 30-40 nm) were utilized and MT/HA interactions were examined using multi-instrumental approach including electrochemistry, electrophoretic methods, and MALDI-TOF/TOF mass spectrometry. It was found that peptides enter mutual creation of complexes, which are based on some of nonbonded interactions. The higher willingness to interact was observed in MT-derived peptides toward immobilized HA. Finally, we designed and manufactured flow-through electrochemical 3D printed device (reservoir volume 150 μL) and utilized it for automated analysis of the HA/MT metal labels. Under the optimal conditions, (deposition time and flow rate 80 s and 1.6 mL/min for CuS and 120 s and 1.6 mL/min PbS, respectively), the results of peptide-conjugated QDs were comparable with atomic absorption spectrometry.

  16. Comparison of 3D laser-based photonic scans and manual anthropometric measurements of body size and shape in a validation study of 123 young Swiss men

    PubMed Central

    Zwahlen, Marcel; Wells, Jonathan C.; Bender, Nicole; Henneberg, Maciej

    2017-01-01

    Background Manual anthropometric measurements are time-consuming and challenging to perform within acceptable intra- and inter-individual error margins in large studies. Three-dimensional (3D) laser body scanners provide a fast and precise alternative: within a few seconds the system produces a 3D image of the body topography and calculates some 150 standardised body size measurements. Objective The aim was to enhance the small number of existing validation studies and compare scan and manual techniques based on five selected measurements. We assessed the agreement between two repeated measurements within the two methods, analysed the direct agreement between the two methods, and explored the differences between the techniques when used in regressions assessing the effect of health related determinants on body shape indices. Methods We performed two repeated body scans on 123 volunteering young men using a Vitus Smart XXL body scanner. We manually measured height, waist, hip, buttock, and chest circumferences twice for each participant according to the WHO guidelines. The participants also filled in a basic questionnaire. Results Mean differences between the two scan measurements were smaller than between the two manual measurements, and precision as well as intra-class correlation coefficients were higher. Both techniques were strongly correlated. When comparing means between both techniques we found significant differences: Height was systematically shorter by 2.1 cm, whereas waist, hip and bust circumference measurements were larger in the scans by 1.17–4.37 cm. In consequence, body shape indices also became larger and the prevalence of overweight was greater when calculated from the scans. Between 4.1% and 7.3% of the probands changed risk category from normal to overweight when classified based on the scans. However, when employing regression analyses the two measurement techniques resulted in very similar coefficients, confidence intervals, and p

  17. Intraoperative evaluation of device placement in spine surgery using known-component 3D-2D image registration.

    PubMed

    Uneri, A; De Silva, T; Goerres, J; Jacobson, M W; Ketcha, M D; Reaungamornrat, S; Kleinszig, G; Vogt, S; Khanna, A J; Osgood, G M; Wolinsky, J-P; Siewerdsen, J H

    2017-04-21

    Intraoperative x-ray radiography/fluoroscopy is commonly used to assess the placement of surgical devices in the operating room (e.g. spine pedicle screws), but qualitative interpretation can fail to reliably detect suboptimal delivery and/or breach of adjacent critical structures. We present a 3D-2D image registration method wherein intraoperative radiographs are leveraged in combination with prior knowledge of the patient and surgical components for quantitative assessment of device placement and more rigorous quality assurance (QA) of the surgical product. The algorithm is based on known-component registration (KC-Reg) in which patient-specific preoperative CT and parametric component models are used. The registration performs optimization of gradient similarity, removes the need for offline geometric calibration of the C-arm, and simultaneously solves for multiple component bodies, thereby allowing QA in a single step (e.g. spinal construct with 4-20 screws). Performance was tested in a spine phantom, and first clinical results are reported for QA of transpedicle screws delivered in a patient undergoing thoracolumbar spine surgery. Simultaneous registration of ten pedicle screws (five contralateral pairs) demonstrated mean target registration error (TRE) of 1.1  ±  0.1 mm at the screw tip and 0.7  ±  0.4° in angulation when a prior geometric calibration was used. The calibration-free formulation, with the aid of component collision constraints, achieved TRE of 1.4  ±  0.6 mm. In all cases, a statistically significant improvement (p  <  0.05) was observed for the simultaneous solutions in comparison to previously reported sequential solution of individual components. Initial application in clinical data in spine surgery demonstrated TRE of 2.7  ±  2.6 mm and 1.5  ±  0.8°. The KC-Reg algorithm offers an independent check and quantitative QA of the surgical product using radiographic/fluoroscopic views

  18. 3D reconstruction of VZV infected cell nuclei and PML nuclear cages by serial section array scanning electron microscopy and electron tomography.

    PubMed

    Reichelt, Mike; Joubert, Lydia; Perrino, John; Koh, Ai Leen; Phanwar, Ibanri; Arvin, Ann M

    2012-01-01

    Varicella-zoster virus (VZV) is a human alphaherpesvirus that causes varicella (chickenpox) and herpes zoster (shingles). Like all herpesviruses, the VZV DNA genome is replicated in the nucleus and packaged into nucleocapsids that must egress across the nuclear membrane for incorporation into virus particles in the cytoplasm. Our recent work showed that VZV nucleocapsids are sequestered in nuclear cages formed from promyelocytic leukemia protein (PML) in vitro and in human dorsal root ganglia and skin xenografts in vivo. We sought a method to determine the three-dimensional (3D) distribution of nucleocapsids in the nuclei of herpesvirus-infected cells as well as the 3D shape, volume and ultrastructure of these unique PML subnuclear domains. Here we report the development of a novel 3D imaging and reconstruction strategy that we term Serial Section Array-Scanning Electron Microscopy (SSA-SEM) and its application to the analysis of VZV-infected cells and these nuclear PML cages. We show that SSA-SEM permits large volume imaging and 3D reconstruction at a resolution sufficient to localize, count and distinguish different types of VZV nucleocapsids and to visualize complete PML cages. This method allowed a quantitative determination of how many nucleocapsids can be sequestered within individual PML cages (sequestration capacity), what proportion of nucleocapsids are entrapped in single nuclei (sequestration efficiency) and revealed the ultrastructural detail of the PML cages. More than 98% of all nucleocapsids in reconstructed nuclear volumes were contained in PML cages and single PML cages sequestered up to 2,780 nucleocapsids, which were shown by electron tomography to be embedded and cross-linked by an filamentous electron-dense meshwork within these unique subnuclear domains. This SSA-SEM analysis extends our recent characterization of PML cages and provides a proof of concept for this new strategy to investigate events during virion assembly at the single cell

  19. 3D Reconstruction of VZV Infected Cell Nuclei and PML Nuclear Cages by Serial Section Array Scanning Electron Microscopy and Electron Tomography

    PubMed Central

    Reichelt, Mike; Joubert, Lydia; Perrino, John; Koh, Ai Leen; Phanwar, Ibanri; Arvin, Ann M.

    2012-01-01

    Varicella-zoster virus (VZV) is a human alphaherpesvirus that causes varicella (chickenpox) and herpes zoster (shingles). Like all herpesviruses, the VZV DNA genome is replicated in the nucleus and packaged into nucleocapsids that must egress across the nuclear membrane for incorporation into virus particles in the cytoplasm. Our recent work showed that VZV nucleocapsids are sequestered in nuclear cages formed from promyelocytic leukemia protein (PML) in vitro and in human dorsal root ganglia and skin xenografts in vivo. We sought a method to determine the three-dimensional (3D) distribution of nucleocapsids in the nuclei of herpesvirus-infected cells as well as the 3D shape, volume and ultrastructure of these unique PML subnuclear domains. Here we report the development of a novel 3D imaging and reconstruction strategy that we term Serial Section Array-Scanning Electron Microscopy (SSA-SEM) and its application to the analysis of VZV-infected cells and these nuclear PML cages. We show that SSA-SEM permits large volume imaging and 3D reconstruction at a resolution sufficient to localize, count and distinguish different types of VZV nucleocapsids and to visualize complete PML cages. This method allowed a quantitative determination of how many nucleocapsids can be sequestered within individual PML cages (sequestration capacity), what proportion of nucleocapsids are entrapped in single nuclei (sequestration efficiency) and revealed the ultrastructural detail of the PML cages. More than 98% of all nucleocapsids in reconstructed nuclear volumes were contained in PML cages and single PML cages sequestered up to 2,780 nucleocapsids, which were shown by electron tomography to be embedded and cross-linked by an filamentous electron-dense meshwork within these unique subnuclear domains. This SSA-SEM analysis extends our recent characterization of PML cages and provides a proof of concept for this new strategy to investigate events during virion assembly at the single cell

  20. Back Analysis of the 2014 San Leo Landslide Using Combined Terrestrial Laser Scanning and 3D Distinct Element Modelling

    NASA Astrophysics Data System (ADS)

    Spreafico, Margherita Cecilia; Francioni, Mirko; Cervi, Federico; Stead, Doug; Bitelli, Gabriele; Ghirotti, Monica; Girelli, Valentina Alena; Lucente, Claudio Corrado; Tini, Maria Alessandra; Borgatti, Lisa

    2016-06-01

    Landslides of the lateral spreading type, involving brittle geological units overlying ductile terrains, are a common occurrence in the sandstone and limestone plateaux of the northern Apennines of Italy. The edges of these plateaux are often the location of rapid landslide phenomena, such as rock slides, rock falls and topples. In this paper, we present a back analysis of a recent landslide (February 2014), involving the north-eastern sector of the San Leo rock slab (northern Apennines, Emilia-Romagna Region) which is a representative example of this type of phenomena. The aquifer hosted in the fractured slab, due to its relatively higher secondary permeability in comparison to the lower clayey units leads to the development of perennial and ephemeral springs at the contact between the two units. The related piping erosion phenomena, together with slope processes in the clay-shales have led to the progressive undermining of the slab, eventually predisposing large-scale landslides. Stability analyses were conducted coupling terrestrial laser scanning (TLS) and distinct element methods (DEMs). TLS point clouds were analysed to determine the pre- and post-failure geometry, the extension of the detachment area and the joint network characteristics. The block dimensions in the landslide deposit were mapped and used to infer the spacing of the discontinuities for insertion into the numerical model. Three-dimensional distinct element simulations were conducted, with and without undermining of the rock slab. The analyses allowed an assessment of the role of the undermining, together with the presence of an almost vertical joint set, striking sub-parallel to the cliff orientation, on the development of the slope instability processes. Based on the TLS and on the numerical simulation results, an interpretation of the landslide mechanism is proposed.

  1. 3D digital image processing for biofilm quantification from confocal laser scanning microscopy: Multidimensional statistical analysis of biofilm modeling

    NASA Astrophysics Data System (ADS)

    Zielinski, Jerzy S.

    The dramatic increase in number and volume of digital images produced in medical diagnostics, and the escalating demand for rapid access to these relevant medical data, along with the need for interpretation and retrieval has become of paramount importance to a modern healthcare system. Therefore, there is an ever growing need for processed, interpreted and saved images of various types. Due to the high cost and unreliability of human-dependent image analysis, it is necessary to develop an automated method for feature extraction, using sophisticated mathematical algorithms and reasoning. This work is focused on digital image signal processing of biological and biomedical data in one- two- and three-dimensional space. Methods and algorithms presented in this work were used to acquire data from genomic sequences, breast cancer, and biofilm images. One-dimensional analysis was applied to DNA sequences which were presented as a non-stationary sequence and modeled by a time-dependent autoregressive moving average (TD-ARMA) model. Two-dimensional analyses used 2D-ARMA model and applied it to detect breast cancer from x-ray mammograms or ultrasound images. Three-dimensional detection and classification techniques were applied to biofilm images acquired using confocal laser scanning microscopy. Modern medical images are geometrically arranged arrays of data. The broadening scope of imaging as a way to organize our observations of the biophysical world has led to a dramatic increase in our ability to apply new processing techniques and to combine multiple channels of data into sophisticated and complex mathematical models of physiological function and dysfunction. With explosion of the amount of data produced in a field of biomedicine, it is crucial to be able to construct accurate mathematical models of the data at hand. Two main purposes of signal modeling are: data size conservation and parameter extraction. Specifically, in biomedical imaging we have four key problems

  2. Three-dimensional scanning near field optical microscopy (3D-SNOM) imaging of random arrays of copper nanoparticles: implications for plasmonic solar cell enhancement

    NASA Astrophysics Data System (ADS)

    Ezugwu, Sabastine; Ye, Hanyang; Fanchini, Giovanni

    2014-11-01

    In order to investigate the suitability of random arrays of nanoparticles for plasmonic enhancement in the visible-near infrared range, we introduced three-dimensional scanning near-field optical microscopy (3D-SNOM) imaging as a useful technique to probe the intensity of near-field radiation scattered by random systems of nanoparticles at heights up to several hundred nm from their surface. We demonstrated our technique using random arrays of copper nanoparticles (Cu-NPs) at different particle diameter and concentration. Bright regions in the 3D-SNOM images, corresponding to constructive interference of forward-scattered plasmonic waves, were obtained at heights Δz >= 220 nm from the surface for random arrays of Cu-NPs of ~60-100 nm in diameter. These heights are too large to use Cu-NPs in contact of the active layer for light harvesting in thin organic solar cells, which are typically no thicker than 200 nm. Using a 200 nm transparent spacer between the system of Cu-NPs and the solar cell active layer, we demonstrate that forward-scattered light can be conveyed in 200 nm thin film solar cells. This architecture increases the solar cell photoconversion efficiency by a factor of 3. Our 3D-SNOM technique is general enough to be suitable for a large number of other applications in nanoplasmonics.In order to investigate the suitability of random arrays of nanoparticles for plasmonic enhancement in the visible-near infrared range, we introduced three-dimensional scanning near-field optical microscopy (3D-SNOM) imaging as a useful technique to probe the intensity of near-field radiation scattered by random systems of nanoparticles at heights up to several hundred nm from their surface. We demonstrated our technique using random arrays of copper nanoparticles (Cu-NPs) at different particle diameter and concentration. Bright regions in the 3D-SNOM images, corresponding to constructive interference of forward-scattered plasmonic waves, were obtained at heights Δz >= 220

  3. Analysis of the Geometry of the Distal Femur and Proximal Tibia in the Osteoarthritic Knee: A 3D Reconstruction CT Scan Based Study of 449 Cases

    PubMed Central

    Lyras, Dimitrios N.; Loucks, Craig; Greenhow, Robert

    2016-01-01

    Background: The aim of this study is to evaluate the geometry of the distal femur and the proximal tibia in the osteoarthritic knee using 3D reconstructive CT scan imaging. Methods: 449 patients with knee osteoarthritis were treated surgically in our center with patient-specific technology total knee arthroplasty. Preoperatively, all the patients underwent a CT scan according to a standard protocol. Using this database, the Hip-Knee-Angle (HKA), the Femur Valgus Angle (FVA), the Tibia Varus Angle (TVA), the Posterior Tibia Slope (PTS), and the angle between the posterior condylar axis and the anatomical transepicondylar axis (PCA) for each patient were recorded and statistically evaluated. Results: In overall, the mean HKA angle was 177.3±5.55, the mean FVA angle was 3.19±2.08, the mean TVA was 3.28±2.35, the PTS angle was 9.02±3.46, and the PCA angle was 2.86±0.78. Evaluation of the correlations between HKA and PCA (r=0.035), HKA and PTS (r=-0.047), and PCA and PTS (r=0.05) showed non-significant relationships (P=0.46, P=0.32, and P=0.29 respectively). No significant differences were revealed from the comparison of male patients with female patients, regarding the mean HKA, FVA, TVA, PTS, and PCA. Conclusion: The posterior condylar axis is a well-defined but not a reliable axis, while the transepicondylar and the anteroposterior are reliable, but not easily defined axes. Given the large ranges and standard deviations of the location of posterior condylar axis, and the important inter- and intraobserver variability in the intraoperative location of the transepicondylar and the anteroposterior axes, the use of a preoperative 3D CT scan is recommended. PMID:27200387

  4. The use of radiochromic EBT2 film for the quality assurance and dosimetric verification of 3D conformal radiotherapy using Microtek ScanMaker 9800XL flatbed scanner.

    PubMed

    Sim, G S; Wong, J H D; Ng, K H

    2013-07-08

    Radiochromic and radiographic films are widely used for radiation dosimetry due to the advantage of high spatial resolution and two-dimensional dose measurement. Different types of scanners, including various models of flatbed scanners, have been used as part of the dosimetry readout procedure. This paper focuses on the characterization of the EBT2 film response in combination with a Microtek ScanMaker 9800XL scanner and the subsequent use in the dosimetric verification of a 3D conformal radiotherapy treatment. The film reproducibility and scanner uniformity of the Microtek ScanMaker 9800XL was studied. A three-field 3D conformal radiotherapy treatment was planned on an anthropomorphic phantom and EBT2 film measurements were carried out to verify the treatment. The interfilm reproducibility was found to be 0.25%. Over a period of three months, the films darkened by 1%. The scanner reproducibility was ± 2% and a nonuniformity was ±1.9% along the direction perpendicular to the scan direction. EBT2 measurements showed an underdose of 6.2% at high-dose region compared to TPS predicted dose. This may be due to the inability of the treatment planning system to predict the correct dose distribution in the presence of tissue inhomogeneities and the uncertainty of the scanner reproducibility and uniformity. The use of EBT2 film in conjunction with the axial CT image of the anthropomorphic phantom allows the evaluation of the anatomical location of dose discrepancies between the EBT2 measured dose distribution and TPS predicted dose distribution.

  5. Temperature mapping of operating nanoscale devices by scanning probe thermometry

    NASA Astrophysics Data System (ADS)

    Menges, Fabian; Mensch, Philipp; Schmid, Heinz; Riel, Heike; Stemmer, Andreas; Gotsmann, Bernd

    2016-03-01

    Imaging temperature fields at the nanoscale is a central challenge in various areas of science and technology. Nanoscopic hotspots, such as those observed in integrated circuits or plasmonic nanostructures, can be used to modify the local properties of matter, govern physical processes, activate chemical reactions and trigger biological mechanisms in living organisms. The development of high-resolution thermometry techniques is essential for understanding local thermal non-equilibrium processes during the operation of numerous nanoscale devices. Here we present a technique to map temperature fields using a scanning thermal microscope. Our method permits the elimination of tip-sample contact-related artefacts, a major hurdle that so far has limited the use of scanning probe microscopy for nanoscale thermometry. We map local Peltier effects at the metal-semiconductor contacts to an indium arsenide nanowire and self-heating of a metal interconnect with 7 mK and sub-10 nm spatial temperature resolution.

  6. Temperature mapping of operating nanoscale devices by scanning probe thermometry

    PubMed Central

    Menges, Fabian; Mensch, Philipp; Schmid, Heinz; Riel, Heike; Stemmer, Andreas; Gotsmann, Bernd

    2016-01-01

    Imaging temperature fields at the nanoscale is a central challenge in various areas of science and technology. Nanoscopic hotspots, such as those observed in integrated circuits or plasmonic nanostructures, can be used to modify the local properties of matter, govern physical processes, activate chemical reactions and trigger biological mechanisms in living organisms. The development of high-resolution thermometry techniques is essential for understanding local thermal non-equilibrium processes during the operation of numerous nanoscale devices. Here we present a technique to map temperature fields using a scanning thermal microscope. Our method permits the elimination of tip–sample contact-related artefacts, a major hurdle that so far has limited the use of scanning probe microscopy for nanoscale thermometry. We map local Peltier effects at the metal–semiconductor contacts to an indium arsenide nanowire and self-heating of a metal interconnect with 7 mK and sub-10 nm spatial temperature resolution. PMID:26936427

  7. The Structure of the Kaali Impact Crater (Estonia) based on 3D Laser Scanning, Photogrammetric Modelling and Strike and Dip Measurements

    NASA Astrophysics Data System (ADS)

    Zanetti, Michael; Wilk, Jakob; Joeleht, Argo; Välja, Rudolf; Losiak, Anna; Wisniowski, Tomek; Huber, Matthew; Pavel, Kristiina; Kriiska, Aivar; Plado, Jüri; Geppert, Wolf Dietrich; Kukko, Antero; Kaartinen, Harri

    2015-04-01

    Introduction: The Kaali Impact Crater on the island of Saaremaa, Estonia (58.37° N, 22.67° E) is part of a crater-strewn-field consisting of nine identified craters, ranging in size from 110m (Kaali Main) to a few meters in diameter [1-3]. The strewn field was formed by the breakup of an IAB iron meteorite during atmospheric entry [4]. The main crater is due to its size an important crater to study the effects of small asteroidal impacts on terrestrial planets. Despite some anthropomorphic changes, the crater is well preserved. During a scientific expedition in August 2014, we mapped the crater in unprecedented detail using 3D laser scanning tools and made detailed strike and dip measurements of all outcrops. Additional measurements using ground-penetrating radar and electro-resistivity tomography we also conducted to further refine the subsurface crater morphology. The results include a high resolution topographic map of the crater, previously unreported observations of overturned ejecta, and refined morphometric estimates of the crater. Additionally, research conducted as part of the expedition has provided a new, best-estimate for the formation of the crater (3200a +/- 30 BP) based on 14C AMS dating of charcoal from within the ejecta blanket [Losiak et al., 2015, this conference]. Structural Mapping: Although Kaali Main has been the subject of previous investigation (e.g. [2,5,6]), most of the structural descriptions of the crater pre-date modern crater investigations. Strongly inclined blocks were previously considered being affected by erosion and slope processes, our new observations show that most high dip-angle features fit well with overall dip-angle systematics. The existence of the overturned flap can be demonstrated in at least four areas around the crater. 3D Laser Scanning: A point cloud containing 16 million data points was created using 43 individual scans from a tripod mounted Faro 3D 330x laser scanner. Scans were processed using Trimble

  8. 75 FR 34482 - Certain Biometric Scanning Devices, Components Thereof, Associated Software, and Products...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-17

    ... COMMISSION Certain Biometric Scanning Devices, Components Thereof, Associated Software, and Products..., associated software, and products containing the same by reason of infringement of certain claims of U.S... certain biometric scanning devices, components thereof, associated software, or products containing...

  9. LeasyScan: a novel concept combining 3D imaging and lysimetry for high-throughput phenotyping of traits controlling plant water budget.

    PubMed

    Vadez, Vincent; Kholová, Jana; Hummel, Grégoire; Zhokhavets, Uladzimir; Gupta, S K; Hash, C Tom

    2015-09-01

    In this paper, we describe the thought process and initial data behind the development of an imaging platform (LeasyScan) combined with lysimetric capacity, to assess canopy traits affecting water use (leaf area, leaf area index, transpiration). LeasyScan is based on a novel 3D scanning technique to capture leaf area development continuously, a scanner-to-plant concept to increase imaging throughput and analytical scales to combine gravimetric transpiration measurements. The paper presents how the technology functions, how data are visualised via a web-based interface and how data extraction and analysis is interfaced through 'R' libraries. Close agreement between scanned and observed leaf area data of individual plants in different crops was found (R(2) between 0.86 and 0.94). Similar agreement was found when comparing scanned and observed area of plants cultivated at densities reflecting field conditions (R(2) between 0.80 and 0.96). An example in monitoring plant transpiration by the analytical scales is presented. The last section illustrates some of the early ongoing applications of the platform to target key phenotypes: (i) the comparison of the leaf area development pattern of fine mapping recombinants of pearl millet; (ii) the leaf area development pattern of pearl millet breeding material targeted to different agro-ecological zones; (iii) the assessment of the transpiration response to high VPD in sorghum and pearl millet. This new platform has the potential to phenotype for traits controlling plant water use at a high rate and precision, of critical importance for drought adaptation, and creates an opportunity to harness their genetics for the breeding of improved varieties.

  10. Prenatal diagnosis, 3-D virtual rendering and lung sparing surgery by ligasure device in a baby with “CCAM and intralobar pulmonary sequestration”

    PubMed Central

    Molinaro, Francesco; Angotti, Rossella; Di Crescenzo, Vincenzo Giuseppe; Cortese, Antonio; Messina, Mario

    2016-01-01

    Abstract Congenital cystic lung lesions are a rare but clinically significant group of anomalies, including congenital cystic adenomatoid malformation (CCAM), pulmonary sequestration, congenital lobar emphysema (CLE) and bronchogenic cysts. Despite the knowledge of these lesions increasing in the last years, some aspects are still debated and controversial. The diagnosis is certainly one aspect which underwent many changes in the last 15 years due to the improvement of antenatal scan and the introduction of 3-D reconstruction techniques. As it is known, a prompt diagnosis has an essential role in the management of these children. The new imaging studies as 3D Volume rendering system are the focus of this paper. We describe our preliminary experience in a case of hybrid lung lesion, which we approached by thoracoscopy after a preoperative study with 3D VR reconstruction. Our final balance is absolutely positive. PMID:28352794

  11. An Evaluation of the Observational Capabilities of A Scanning 95-GHz Radar in Studying the 3D Structures of Marine Stratocumulus Clouds

    NASA Astrophysics Data System (ADS)

    Bowley, Kevin

    Marine stratocumulus clouds play a critical role in Earth's radiative balance primarily due to the role of their high albedo reflecting incoming solar radiation, causing a cooling effect, while weakly reflecting outgoing infrared radiation. Characterization of the 3-Dimensional (3D) structure of these cloud systems over scales of 20-40 km is required to accurately account for the role of cloud inhomogeneity and structure on their shortwave forcing and lifetime, which has important applications for Global Climate Models. For first time, such 3D measurements in clouds were made available from a scanning cloud radar during the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) program's Clouds, Aerosol, and Precipitation in the Marine Boundary Layer (CAP-MBL) field campaign in the Azores Islands. The scanning radar observations were complemented by a suite of zenith-pointing active and passive remote sensors that were deployed to provide a detailed description of marine stratus over a long-term observation period in the ideal marine environment commonly found at the Azores. The scanning cloud radar observations present a shift from a multi-instrument, vertically pointing 'soda-straw' observation technique to a radar-only, 'radar-centric' observation technique. The scanning radar observations were gridded using a nearest-neighbor type scheme devised to take the natural variability of the observed field into account. The ability of the scheme to capture primary cloud properties (cloud fraction, cloud boundaries, drizzle detection) was assessed using measurements from the vertically pointing sensors. Despite the great sensitivity of the scanning cloud radar (-42.5 dBZ at 1 km range), the drop in sensitivity with range resulted in an artificial thinning of clouds with range from the radar. Drizzle-free cloud structures were undetectable beyond 5 km from the radar. Cloud fields containing drizzle were generally detectable to ranges exceeding 10 km from

  12. 3D mechanical analysis of aeronautical plain bearings: Validation of a finite element model from measurement of displacement fields by digital volume correlation and optical scanning tomography

    NASA Astrophysics Data System (ADS)

    Germaneau, A.; Peyruseigt, F.; Mistou, S.; Doumalin, P.; Dupré, J.-C.

    2010-06-01

    On Airbus aircraft, spherical plain bearings are used on many components; in particular to link engine to pylon or pylon to wing. Design of bearings is based on contact pressure distribution on spherical surfaces. To determine this distribution, a 3D analysis of the mechanical behaviour of aeronautical plain bearing is presented in this paper. A numerical model has been built and validated from a comparison with 3D experimental measurements of kinematic components. For that, digital volume correlation (DVC) coupled with optical scanning tomography (OST) is employed to study the mechanical response of a plain bearing model made in epoxy resin. Experimental results have been compared with the ones obtained from the simulated model. This comparison enables us to study the influence of various boundary conditions to build the FE model. Some factors have been highlighted like the fitting behaviour which can radically change contact pressure distribution. This work shows the contribution of a representative mechanical environment to study precisely mechanical response of aeronautical plain bearings.

  13. 2D and 3D documentation of St. Nicolas baroque church for the general reconstruction using laser scanning and photogrammetry technologies combination

    NASA Astrophysics Data System (ADS)

    Křemen, Tomáš; Koska, Bronislav

    2013-04-01

    Total reconstruction of a historical object is a complicated process consisting of several partial steps. One of these steps is acquiring high-quality data for preparation of the project documentation. If these data are not available from the previous periods, it is necessary to proceed to a detailed measurement of the object and to create a required drawing documentation. New measurement of the object brings besides its costs also several advantages as complex content and form of drawings exactly according to the requirements together with their high accuracy. The paper describes measurement of the Baroque church by the laser scanning method extended by the terrestrial and air photogrammetry. It deals with processing the measured data and creating the final outputs, which is a 2D drawing documentation, orthophotos and a 3D model. Attention is focused on their problematic parts like interconnection of the measurement data acquired by various technologies, creation of orthophotos and creation of the detailed combined 3D model of the church exterior. Results of this work were used for preparation of the planned reconstruction of the object.

  14. The benefit of 3D laser scanning technology in the generation and calibration of FEM models for health assessment of concrete structures.

    PubMed

    Yang, Hao; Xu, Xiangyang; Neumann, Ingo

    2014-11-19

    Terrestrial laser scanning technology (TLS) is a new technique for quickly getting three-dimensional information. In this paper we research the health assessment of concrete structures with a Finite Element Method (FEM) model based on TLS. The goal focuses on the benefits of 3D TLS in the generation and calibration of FEM models, in order to build a convenient, efficient and intelligent model which can be widely used for the detection and assessment of bridges, buildings, subways and other objects. After comparing the finite element simulation with surface-based measurement data from TLS, the FEM model is determined to be acceptable with an error of less than 5%. The benefit of TLS lies mainly in the possibility of a surface-based validation of results predicted by the FEM model.

  15. Patterns of variation and match rates of the anterior biting dentition: characteristics of a database of 3D-scanned dentitions.

    PubMed

    Sheets, H David; Bush, Peter J; Bush, Mary A

    2013-01-01

    An understanding of the variability of the anterior human dentition is essential in bitemark analysis. A collection of 1099 3D laser scans of paired maxillary and mandibular arches were studied using geometric morphometric methods. Analyses were performed without scale (shape only) and with scale (shape and size). Specimens differing by no more than experimentally obtained measurement error were counted as matches, or as indistinguishable. A total of 487 maxillary (396 size preserved), 131 mandibular (83 size preserved), and one paired dentition (two size preserved) matches were found. Principal component analysis and partial least squares revealed interpretable patterns of variation and covariation in dental shape, principally dominated by variation in dental arch width. The sensitivity of match rate to assumed degree of measurement error was also determined showing rapid increases in match rate as measurement error increased. In conclusion, the concept of dental uniqueness with regard to bitemark analysis should be approached with caution.

  16. Separating Leaves from Trunks and Branches with Dual-Wavelength Terrestrial Lidar Scanning: Improving Canopy Structure Characterization in 3-D Space

    NASA Astrophysics Data System (ADS)

    Li, Z.; Strahler, A. H.; Schaaf, C.; Howe, G.; Martel, J.; Hewawasam, K.; Douglas, E. S.; Chakrabarti, S.; Cook, T.; Paynter, I.; Saenz, E.; Wang, Z.; Yang, X.; Yao, T.; Zhao, F.; Woodcock, C.; Jupp, D.; Schaefer, M.; Culvenor, D.; Newnham, G.; Lowell, J.

    2013-12-01

    Leaf area index (LAI) is an important parameter characterizing forest structure, used in models regulating the exchange of carbon, water and energy between the land and the atmosphere. However, optical methods in common use cannot separate leaf area from the area of upper trunks and branches, and thus retrieve only plant area index (PAI), which is adjusted to LAI using an appropriate empirical woody-to-total index. An additional problem is that the angular distributions of leaf normals and normals to woody surfaces are quite different, and thus leafy and woody components project quite different areas with varying zenith angle of view. This effect also causes error in LAI retrieval using optical methods. Full-waveform scans at both the NIR (1064 nm) and SWIR (1548 nm) wavelengths from the new terrestrial Lidar, the Dual-Wavelength Echidna Lidar (DWEL), which pulses in both wavelengths simultaneously, easily separate returns of leaves from trunks and branches in 3-D space. In DWEL scans collected at two different forest sites, Sierra National Forest in June 2013 and Brisbane Karawatha Forest Park in July 2013, the power returned from leaves is similar to power returned from trunks/branches at the NIR wavelength, whereas the power returned from leaves is much lower (only about half as large) at the SWIR wavelength. At the SWIR wavelength, the leaf scattering is strongly attenuated by liquid water absorption. Normalized difference index (NDI) images from the waveform mean intensity at the two wavelengths demonstrate a clear contrast between leaves and trunks/branches. The attached image shows NDI from a part of a scan of an open red fir stand in the Sierra National Forest. Leaves appear light, while other objects are darker.Dual-wavelength point clouds generated from the full waveform data show weaker returns from leaves than from trunks/branches. A simple threshold classification of the NDI value of each scattering point readily separates leaves from trunks and

  17. Evaluating 3D printing to solve the sample-to-device interface for LRS and POC diagnostics: example of an interlock meter-mix device for metering and lysing clinical urine samples.

    PubMed

    Jue, Erik; Schoepp, Nathan G; Witters, Daan; Ismagilov, Rustem F

    2016-05-21

    This paper evaluates the potential of 3D printing, a semi-automated additive prototyping technology, as a means to design and prototype a sample-to-device interface, amenable to diagnostics in limited-resource settings, where speed, accuracy and user-friendly design are critical components. As a test case, we built and validated an interlock meter-mix device for accurately metering and lysing human urine samples for use in downstream nucleic acid amplification. Two plungers and a multivalve generated and controlled fluid flow through the device and demonstrate the utility of 3D printing to create leak-free seals. Device operation consists of three simple steps that must be performed sequentially, eliminating manual pipetting and vortexing to provide rapid (5 to 10 s) and accurate metering and mixing. Bretherton's prediction was applied, using the bond number to guide a design that prevents potentially biohazardous samples from leaking from the device. We employed multi-material 3D printing technology, which allows composites with rigid and elastomeric properties to be printed as a single part. To validate the meter-mix device with a clinically relevant sample, we used urine spiked with inactivated Chlamydia trachomatis and Neisseria gonorrhoeae. A downstream nucleic acid amplification by quantitative PCR (qPCR) confirmed there was no statistically significant difference between samples metered and mixed using the standard protocol and those prepared with the meter-mix device, showing the 3D-printed device could accurately meter, mix and dispense a human urine sample without loss of nucleic acids. Although there are some limitations to 3D printing capabilities (e.g. dimension limitations related to support material used in the printing process), the advantages of customizability, modularity and rapid prototyping illustrate the utility of 3D printing for developing sample-to-device interfaces for diagnostics.

  18. Methodological Developments in 3d Scanning and Modelling of Archaeological French Heritage Site : the Bronze Age Painted Cave of "LES FRAUX", Dordogne (france)

    NASA Astrophysics Data System (ADS)

    Burens, A.; Grussenmeyer, P.; Guillemin, S.; Carozza, L.; Lévêque, F.; Mathé, V.

    2013-07-01

    For six years, an interdisciplinary team of archaeologists, surveyors, environmentalists and archaeometrists have jointly carried out the study of a Bronze Age painted cave, registrered in the French Historical Monuments. The archaeological cave of Les Fraux (Saint-Martin-de-Fressengeas, Dordogne) forms a wide network of galleries, characterized by the exceptional richness of its archaeological remains such as ceramic and metal deposits, parietal representation and about domestic fireplaces. This cave is the only protohistorical site in Europe wherein are gathered testimonies of domestic, spiritual and artistic activities. Fortunately, the cave was closed at the end of the Bronze Age, following to the collapse of its entrance. The site was re-discovered in 1989 and its study started in 2007. The study in progress takes place in a new kind of tool founded by the CNRS's Institute of Ecology and Environment. The purpose of this observatory is the promotion of new methodologies and experimental studies in Global Ecology. In that framework, 3D models of the cave constitute the common work support and the best way for scientific communication for the various studies conducted on the site by nearly forty researchers. In this specific context, a partnership among archaeologists and surveyors from INSA Strasbourg allows the team to develop, in an interdisciplinary way, new methods of data acquiring based on contact-free measurements techniques in order to acquire a full 3D-documentation. This work is conducted in compliance with the integrity of the site. Different techniques based on Terrestrial Laser Scanning, Digital Photogrammetry and Spatial Imaging System have been used in order to generate a geometric and photorealistic 3D model from the combination of point clouds and photogrammetric images, for both visualization and accurate documentation purposes. Various scales of acquiring and diverse resolutions have been applied according to the subject: global volume cave

  19. 3D active edge silicon sensors: Device processing, yield and QA for the ATLAS-IBL production

    SciTech Connect

    Da Vià, Cinzia; Boscardil, Maurizio; Dalla Betta, GianFranco; Darbo, Giovanni; Fleta, Celeste; Gemme, Claudia; Giacomini, Gabriele; Grenier, Philippe; Grinstein, Sebastian; Hansen, Thor-Erik; Hasi, Jasmine; Kenney, Christopher; Kok, Angela; La Rosa, Alessandro; Micelli, Andrea; Parker, Sherwood; Pellegrini, Giulio; Pohl, David-Leon; Povoli, Marco; Vianello, Elisa; Zorzi, Nicola; Watts, S. J.

    2013-01-01

    3D silicon sensors, where plasma micromachining is used to etch deep narrow apertures in the silicon substrate to form electrodes of PIN junctions, were successfully manufactured in facilities in Europe and USA. In 2011 the technology underwent a qualification process to establish its maturity for a medium scale production for the construction of a pixel layer for vertex detection, the Insertable B-Layer (IBL) at the CERN-LHC ATLAS experiment. The IBL collaboration, following that recommendation from the review panel, decided to complete the production of planar and 3D sensors and endorsed the proposal to build enough modules for a mixed IBL sensor scenario where 25% of 3D modules populate the forward and backward part of each stave. The production of planar sensors will also allow coverage of 100% of the IBL, in case that option was required. This paper will describe the processing strategy which allowed successful 3D sensor production, some of the Quality Assurance (QA) tests performed during the pre-production phase and the production yield to date.

  20. AE3D

    SciTech Connect

    Spong, Donald A

    2016-06-20

    AE3D solves for the shear Alfven eigenmodes and eigenfrequencies in a torodal magnetic fusion confinement device. The configuration can be either 2D (e.g. tokamak, reversed field pinch) or 3D (e.g. stellarator, helical reversed field pinch, tokamak with ripple). The equations solved are based on a reduced MHD model and sound wave coupling effects are not currently included.

  1. Effect of defocusing distance on the contaminated surface of brass ring with nanosecond laser in a 3D laser scanning system

    NASA Astrophysics Data System (ADS)

    Zhao, Mali; Liu, Tiegen; Jiang, Junfeng; Wang, Meng

    2014-08-01

    Defocusing distance plays a key role in laser cleaning result and can be either positive or negative, depending on the focus position relative to the sample surface. In this paper, we investigate the effect of the defocusing distance on the cleaning efficiency of oxidized brass surface. The oxide layer from the surface of a brass ring was processed with a three dimensional (3-D) dynamically focused laser galvanometer scanning system. The relationship between removal efficiency of the oxide layer and the defocusing distance was analyzed. The sample surface topography, element content before and after the laser cleaning were analyzed by a scanning electron microscope (SEM) and Energy-dispersive X-ray spectroscopy (EDS), the surface quality after laser cleaning was analyzed by a Atomic Force Microscope (AFM), the chemical constituents of the oxide layer on the sample surface after being processed with different defocusing distances were examined by x-ray photoelectron spectroscopy (XPS) and Auger electron spectroscopy (AES). The results show that the ratios of Cu/O and Zn/O reach the maximum of 53.2 and 27.78 respectively when the defocusing distance is +0.5 mm. The laser pulses will lose the ability to remove the oxide layer from the substrate surface when the defocusing distance is larger than ±2 mm.

  2. Multi-megahertz OCT: High quality 3D imaging at 20 million A-scans and 4.5 GVoxels per second.

    PubMed

    Wieser, Wolfgang; Biedermann, Benjamin R; Klein, Thomas; Eigenwillig, Christoph M; Huber, Robert

    2010-07-05

    We present ultra high speed optical coherence tomography (OCT) with multi-megahertz line rates and investigate the achievable image quality. The presented system is a swept source OCT setup using a Fourier domain mode locked (FDML) laser. Three different FDML-based swept laser sources with sweep rates of 1, 2.6 and 5.2MHz are compared. Imaging with 4 spots in parallel quadruples the effective speed, enabling depth scan rates as high as 20.8 million lines per second. Each setup provides at least 98dB sensitivity and approximately 10microm resolution in tissue. High quality 2D and 3D imaging of biological samples is demonstrated at full scan speed. A discussion about how to best specify OCT imaging speed is included. The connection between voxel rate, line rate, frame rate and hardware performance of the OCT setup such as sample rate, analog bandwidth, coherence length, acquisition dead-time and scanner duty cycle is provided. Finally, suitable averaging protocols to further increase image quality are discussed.

  3. A framework for geometry acquisition, 3-D printing, simulation, and measurement of head-related transfer functions with a focus on hearing-assistive devices

    PubMed Central

    Harder, Stine; Paulsen, Rasmus R.; Larsen, Martin; Laugesen, Søren; Mihocic, Michael; Majdak, Piotr

    2017-01-01

    Individual head-related transfer functions (HRTFs) are essential in applications like fitting hearing-assistive devices (HADs) for providing accurate sound localization performance. Individual HRTFs are usually obtained through intricate acoustic measurements. This paper investigates the use of a three-dimensional (3D) head model for acquisition of individual HRTFs. Two aspects were investigated; whether a 3D-printed model can replace measurements on a human listener and whether numerical simulations can replace acoustic measurements. For this purpose, HRTFs were acoustically measured for four human listeners and for a 3D printed head model of one of these listeners. Further, HRTFs were simulated by applying the finite element method to the 3D head model. The monaural spectral features and spectral distortions were very similar between re-measurements and between human and printed measurements, however larger deviations were observed between measurement and simulation. The binaural cues were in agreement among all HRTFs of the same listener, indicating that the 3D model is able to provide localization cues potentially accessible to HAD users. Hence, the pipeline of geometry acquisition, printing, and acoustic measurements or simulations, seems to be a promising step forward towards in-silico design of HADs. PMID:28239188

  4. 3D origami-based multifunction-integrated immunodevice: low-cost and multiplexed sandwich chemiluminescence immunoassay on microfluidic paper-based analytical device.

    PubMed

    Ge, Lei; Wang, Shoumei; Song, Xianrang; Ge, Shenguang; Yu, Jinghua

    2012-09-07

    A novel 3D microfluidic paper-based immunodevice, integrated with blood plasma separation from whole blood samples, automation of rinse steps, and multiplexed CL detections, was developed for the first time based on the principle of origami (denoted as origami-based device). This 3D origami-based device, comprised of one test pad surrounded by four folding tabs, could be patterned and fabricated by wax-printing on paper in bulk. In this work, a sandwich-type chemiluminescence (CL) immunoassay was introduced into this 3D origami-based immunodevice, which could separate the operational procedures into several steps including (i) folding pads above/below and (ii) addition of reagent/buffer under a specific sequence. The CL behavior, blood plasma separation, washing protocol, and incubation time were investigated in this work. The developed 3D origami-based CL immunodevice, combined with a typical luminuol-H(2)O(2) CL system and catalyzed by Ag nanoparticles, showed excellent analytical performance for the simultaneous detection of four tumor markers. The whole blood samples were assayed and the results obtained were in agreement with the reference values from the parallel single-analyte test. This paper-based microfluidic origami CL detection system provides a new strategy for a low-cost, sensitive, simultaneous multiplex immunoassay and point-of-care diagnostics.

  5. Pyro-EHD ink-jet printing for direct functionalization of 3D lab-on-chip devices

    NASA Astrophysics Data System (ADS)

    Coppola, S.; Vespini, V.; Bianco, V.; Mecozzi, L.; Olivieri, F.; Todino, M.; Paturzo, M.; Grilli, S.; Ferraro, P.

    2016-03-01

    A challenging request in the fabrication of microfluidics and biomedical microsystems is a flexible ink-jet printing for breaking the rigidity of classical lithography. A pyroelectric-EHD system is presented. The system has proved challenging spatial resolution down to nanoscale, printing of high ordered patterns, capability of dispensing bio-ink as DNA and protein array for biosensing fabrication, single cells printing and direct printing of nanoparticles. With the method proposed high viscous polymers could be easily printed at high resolution in 2D or in 3D configuration. The pyro-EHD process has been proved for the fabrication of biodegradable microneedles for trasndermal drug delivery and 3D optical waveguides.

  6. Estimating a structural bottle neck for eye-brain transfer of visual information from 3D-volumes of the optic nerve head from a commercial OCT device

    NASA Astrophysics Data System (ADS)

    Malmberg, Filip; Sandberg-Melin, Camilla; Söderberg, Per G.

    2016-03-01

    The aim of this project was to investigate the possibility of using OCT optic nerve head 3D information captured with a Topcon OCT 2000 device for detection of the shortest distance between the inner limit of the retina and the central limit of the pigment epithelium around the circumference of the optic nerve head. The shortest distance between these boundaries reflects the nerve fiber layer thickness and measurement of this distance is interesting for follow-up of glaucoma.

  7. Categorisation of full waveform data provided by laser scanning devices

    NASA Astrophysics Data System (ADS)

    Ullrich, Andreas; Pfennigbauer, Martin

    2011-11-01

    In 2004, a laser scanner device for commercial airborne laser scanning applications, the RIEGL LMS-Q560, was introduced to the market, making use of a radical alternative approach to the traditional analogue signal detection and processing schemes found in LIDAR instruments so far: digitizing the echo signals received by the instrument for every laser pulse and analysing these echo signals off-line in a so-called full waveform analysis in order to retrieve almost all information contained in the echo signal using transparent algorithms adaptable to specific applications. In the field of laser scanning the somewhat unspecific term "full waveform data" has since been established. We attempt a categorisation of the different types of the full waveform data found in the market. We discuss the challenges in echo digitization and waveform analysis from an instrument designer's point of view and we will address the benefits to be gained by using this technique, especially with respect to the so-called multi-target capability of pulsed time-of-flight LIDAR instruments.

  8. Construction of a 3D porous network of copper film via a template-free deposition method with superior mechanical and electrical properties for micro-energy devices

    NASA Astrophysics Data System (ADS)

    Peng, Yuncheng; Wang, Yao; Deng, Yuan

    2016-08-01

    With the ever increasing level of performance of energy conversion micro-devices, such as thin-film solar cells and thermoelectric micro-generators or coolers, their reliability and stability still remain a challenge. The high electrical and mechanical stability of an electrode is two of the critical factors that affect the long-term life of devices. Here we show that these factors can be achieved by constructing a 3D porous network of nanostructures in copper film using facile magnetron sputtering technology without any templates. The constructed 3D porous network of nanostructures in Cu film provides not only the advantages of light weight, prominently high conductivity, and large elastic deformation, but also the ability to absorb stress, preventing crack propagation, which is crucial for electrodes to maintain stable electrical and mechanical properties under working conditions. The nanopores inside the 3D network are capable of unrestrained deformation under applied stress resulting in strong elastic recovery. This work puts forward a feasible solution for manufacturing electrodes with excellent electrical and mechanical properties for micro-energy devices.

  9. Integrated 3D view of postmating responses by the Drosophila melanogaster female reproductive tract, obtained by micro-computed tomography scanning.

    PubMed

    Mattei, Alexandra L; Riccio, Mark L; Avila, Frank W; Wolfner, Mariana F

    2015-07-07

    Physiological changes in females during and after mating are triggered by seminal fluid components in conjunction with female-derived molecules. In insects, these changes include increased egg production, storage of sperm, and changes in muscle contraction within the reproductive tract (RT). Such postmating changes have been studied in dissected RT tissues, but understanding their coordination in vivo requires a holistic view of the tissues and their interrelationships. Here, we used high-resolution, multiscale micro-computed tomography (CT) scans to visualize and measure postmating changes in situ in the Drosophila female RT before, during, and after mating. These studies reveal previously unidentified dynamic changes in the conformation of the female RT that occur after mating. Our results also reveal how the reproductive organs temporally shift in concert within the confines of the abdomen. For example, we observed chiral loops in the uterus and in the upper common oviduct that relax and constrict throughout sperm storage and egg movement. We found that specific seminal fluid proteins or female secretions mediate some of the postmating changes in morphology. The morphological movements, in turn, can cause further changes due to the connections among organs. In addition, we observed apparent copulatory damage to the female intima, suggesting a mechanism for entry of seminal proteins, or other exogenous components, into the female's circulatory system. The 3D reconstructions provided by high-resolution micro-CT scans reveal how male and female molecules and anatomy interface to carry out and coordinate mating-dependent changes in the female's reproductive physiology.

  10. Design of smart 3D-digital X-ray microtomographic scanners for non-destructive testing of materials and components of electronic devices with a multilayered structure

    NASA Astrophysics Data System (ADS)

    Syryamkin, V. I.; Suntsov, S. B.; Klestov, S. A.; Echina, E. S.

    2015-10-01

    The article studies the operating procedures of an X-ray microtomographic scanner and the module of reconstruction and analysis 3D-image of a test sample in particular. An algorithm for 3D-image reconstruction based on image shadow projections and mathematical methods of the processing are described. Chapter 1 describes the basic principles of X-ray tomography and general procedures of the device developed. Chapters 2 and 3 are devoted to the problem of resources saving by the system during the X-ray tomography procedure, which is achieved by preprocessing of the initial shadow projections. Preprocessing includes background noise removing from the images, which reduces the amount of shadow projections in general and increases the efficiency of the group shadow projections compression. Chapter 4 covers general procedures of defect search, which is based on vector analysis principles. In conclusion, the main applications of X-ray tomography are presented.

  11. Design of smart 3D-digital X-ray microtomographic scanners for non-destructive testing of materials and components of electronic devices with a multilayered structure

    SciTech Connect

    Syryamkin, V. I. Klestov, S. A. Echina, E. S.; Suntsov, S. B.

    2015-10-27

    The article studies the operating procedures of an X-ray microtomographic scanner and the module of reconstruction and analysis 3D-image of a test sample in particular. An algorithm for 3D-image reconstruction based on image shadow projections and mathematical methods of the processing are described. Chapter 1 describes the basic principles of X-ray tomography and general procedures of the device developed. Chapters 2 and 3 are devoted to the problem of resources saving by the system during the X-ray tomography procedure, which is achieved by preprocessing of the initial shadow projections. Preprocessing includes background noise removing from the images, which reduces the amount of shadow projections in general and increases the efficiency of the group shadow projections compression. Chapter 4 covers general procedures of defect search, which is based on vector analysis principles. In conclusion, the main applications of X-ray tomography are presented.

  12. Optimal alignment of mirror based pentaprisms for scanning deflectometric devices

    SciTech Connect

    Barber, Samuel K.; Geckeler, Ralf D.; Yashchuk, Valeriy V.; Gubarev, Mikhail V.; Buchheim, Jana; Siewert, Frank; Zeschke, Thomas

    2011-03-04

    In the recent work [Proc. of SPIE 7801, 7801-2/1-12 (2010), Opt. Eng. 50(5) (2011), in press], we have reported on improvement of the Developmental Long Trace Profiler (DLTP), a slope measuring profiler available at the Advanced Light Source Optical Metrology Laboratory, achieved by replacing the bulk pentaprism with a mirror based pentaprism (MBPP). An original experimental procedure for optimal mutual alignment of the MBPP mirrors has been suggested and verified with numerical ray tracing simulations. It has been experimentally shown that the optimally aligned MBPP allows the elimination of systematic errors introduced by inhomogeneity of the optical material and fabrication imperfections of the bulk pentaprism. In the present article, we provide the analytical derivation and verification of easily executed optimal alignment algorithms for two different designs of mirror based pentaprisms. We also provide an analytical description for the mechanism for reduction of the systematic errors introduced by a typical high quality bulk pentaprism. It is also shown that residual misalignments of an MBPP introduce entirely negligible systematic errors in surface slope measurements with scanning deflectometric devices.

  13. Transforming Clinical Imaging and 3D Data for Virtual Reality Learning Objects: HTML5 and Mobile Devices Implementation

    ERIC Educational Resources Information Center

    Trelease, Robert B.; Nieder, Gary L.

    2013-01-01

    Web deployable anatomical simulations or "virtual reality learning objects" can easily be produced with QuickTime VR software, but their use for online and mobile learning is being limited by the declining support for web browser plug-ins for personal computers and unavailability on popular mobile devices like Apple iPad and Android…

  14. Automatic determination of trunk diameter, crown base and height of scots pine (Pinus Sylvestris L.) Based on analysis of 3D point clouds gathered from multi-station terrestrial laser scanning. (Polish Title: Automatyczne okreslanie srednicy pnia, podstawy korony oraz wysokosci sosny zwyczajnej (Pinus Silvestris L.) Na podstawie analiz chmur punktow 3D pochodzacych z wielostanowiskowego naziemnego skanowania laserowego)

    NASA Astrophysics Data System (ADS)

    Ratajczak, M.; Wężyk, P.

    2015-12-01

    Rapid development of terrestrial laser scanning (TLS) in recent years resulted in its recognition and implementation in many industries, including forestry and nature conservation. The use of the 3D TLS point clouds in the process of inventory of trees and stands, as well as in the determination of their biometric features (trunk diameter, tree height, crown base, number of trunk shapes), trees and lumber size (volume of trees) is slowly becoming a practice. In addition to the measurement precision, the primary added value of TLS is the ability to automate the processing of the clouds of points 3D in the direction of the extraction of selected features of trees and stands. The paper presents the original software (GNOM) for the automatic measurement of selected features of trees, based on the cloud of points obtained by the ground laser scanner FARO. With the developed algorithms (GNOM), the location of tree trunks on the circular research surface was specified and the measurement was performed; the measurement covered the DBH (l: 1.3m), further diameters of tree trunks at different heights of the tree trunk, base of the tree crown and volume of the tree trunk (the selection measurement method), as well as the tree crown. Research works were performed in the territory of the Niepolomice Forest in an unmixed pine stand (Pinussylvestris L.) on the circular surface with a radius of 18 m, within which there were 16 pine trees (14 of them were cut down). It was characterized by a two-storey and even-aged construction (147 years old) and was devoid of undergrowth. Ground scanning was performed just before harvesting. The DBH of 16 pine trees was specified in a fully automatic way, using the algorithm GNOM with an accuracy of +2.1%, as compared to the reference measurement by the DBH measurement device. The medium, absolute measurement error in the cloud of points - using semi-automatic methods "PIXEL" (between points) and PIPE (fitting the cylinder) in the FARO Scene 5.x

  15. 3D workflow for HDR image capture of projection systems and objects for CAVE virtual environments authoring with wireless touch-sensitive devices

    NASA Astrophysics Data System (ADS)

    Prusten, Mark J.; McIntyre, Michelle; Landis, Marvin

    2006-02-01

    A 3D workflow pipeline is presented for High Dynamic Range (HDR) image capture of projected scenes or objects for presentation in CAVE virtual environments. The methods of HDR digital photography of environments vs. objects are reviewed. Samples of both types of virtual authoring being the actual CAVE environment and a sculpture are shown. A series of software tools are incorporated into a pipeline called CAVEPIPE, allowing for high-resolution objects and scenes to be composited together in natural illumination environments [1] and presented in our CAVE virtual reality environment. We also present a way to enhance the user interface for CAVE environments. The traditional methods of controlling the navigation through virtual environments include: glove, HUD's and 3D mouse devices. By integrating a wireless network that includes both WiFi (IEEE 802.11b/g) and Bluetooth (IEEE 802.15.1) protocols the non-graphical input control device can be eliminated. Therefore wireless devices can be added that would include: PDA's, Smart Phones, TabletPC's, Portable Gaming consoles, and PocketPC's.

  16. 3D Printing to Guide Ventricular Assist Device Placement in Adults With Congenital Heart Disease and Heart Failure.

    PubMed

    Farooqi, Kanwal M; Saeed, Omar; Zaidi, Ali; Sanz, Javier; Nielsen, James C; Hsu, Daphne T; Jorde, Ulrich P

    2016-04-01

    As the population of adults with congenital heart disease continues to grow, so does the number of these patients with heart failure. Ventricular assist devices are underutilized in adults with congenital heart disease due to their complex anatomic arrangements and physiology. Advanced imaging techniques that may increase the utilization of mechanical circulatory support in this population must be explored. Three-dimensional printing offers individualized structural models that would enable pre-surgical planning of cannula and device placement in adults with congenital cardiac disease and heart failure who are candidates for such therapies. We present a review of relevant cardiac anomalies, cases in which such models could be utilized, and some background on the cost and procedure associated with this process.

  17. Transforming clinical imaging and 3D data for virtual reality learning objects: HTML5 and mobile devices implementation.

    PubMed

    Trelease, Robert B; Nieder, Gary L

    2013-01-01

    Web deployable anatomical simulations or "virtual reality learning objects" can easily be produced with QuickTime VR software, but their use for online and mobile learning is being limited by the declining support for web browser plug-ins for personal computers and unavailability on popular mobile devices like Apple iPad and Android tablets. This article describes complementary methods for creating comparable, multiplatform VR learning objects in the new HTML5 standard format, circumventing platform-specific limitations imposed by the QuickTime VR multimedia file format. Multiple types or "dimensions" of anatomical information can be embedded in such learning objects, supporting different kinds of online learning applications, including interactive atlases, examination questions, and complex, multi-structure presentations. Such HTML5 VR learning objects are usable on new mobile devices that do not support QuickTime VR, as well as on personal computers. Furthermore, HTML5 VR learning objects can be embedded in "ebook" document files, supporting the development of new types of electronic textbooks on mobile devices that are increasingly popular and self-adopted for mobile learning.

  18. Novel silicon compatible p-WS2 2D/3D heterojunction devices exhibiting broadband photoresponse and superior detectivity

    NASA Astrophysics Data System (ADS)

    Chowdhury, Rup K.; Maiti, Rishi; Ghorai, Arup; Midya, Anupam; Ray, Samit K.

    2016-07-01

    We report for the first time, the fabrication of novel two-dimensional (2D) p-WS2/n-Si vertical heterostructures with superior junction and photoresponse characteristics. Few layer WS2 has been synthesized by a lithium-ion intercalation technique in hexane and coated on Si substrates for realization of CMOS compatible devices. Atomic force microscopy and Raman spectroscopy have been used to confirm the 2D nature of WS2 layers. Sharp band-edge absorption and emission peaks have indicated the formation of mono-to-few-layers thick direct band gap WS2 films. The electrical and optical responses of the heterostructures have exhibited superior properties revealing the formation of an abrupt heterojunction. The fabricated photodetector device depicts a peak responsivity of 1.11 A W-1 at -2 V with a broadband spectral response of 400-1100 nm and a moderate photo-to-dark current ratio of ~103. The optical switching characteristics have been studied as a function of applied bias and illuminated power density. A comparative study of the reported results on 2D transition metal chalcogenides indicates the superior characteristics of WS2/n-Si heterostructures for future photonic devices.

  19. Ceramic materials of low-temperature synthesis for dielectric coating applied by 3D aerosol printing used in nano- and microelectronics, lighting engineering, and spacecraft control devices

    NASA Astrophysics Data System (ADS)

    Ivanov, A. A.; Tuev, V. I.; Nisan, A. V.; Potapov, G. N.

    2016-11-01

    A synthesis technique of low-temperature ceramic material based on aluminosilicates of dendrimer morphology capable to contain up to 80 wt % of nitrides and oxides of high-melting compounds as filler has been developed. The synthesis is based on a sol-gel method followed by mechanochemical treatment and ultrasonic dispersing. Dielectric ceramic layers with the layer thickness in the nanometer range and high thermal conductivity have been obtained for the first time by 3D aerosol printing of the synthesized material. The study of the obtained ceramic coating on the metal surface (Al) has proved its use prospects in microelectronics, light engineering, and devices for special purposes.

  20. Artificial Neural Networks as a powerful numerical tool to classify specific features of a tooth based on 3D scan data.

    PubMed

    Raith, Stefan; Vogel, Eric Per; Anees, Naeema; Keul, Christine; Güth, Jan-Frederik; Edelhoff, Daniel; Fischer, Horst

    2017-01-01

    Chairside manufacturing based on digital image acquisition is gainingincreasing importance in dentistry. For the standardized application of these methods, it is paramount to have highly automated digital workflows that can process acquired 3D image data of dental surfaces. Artificial Neural Networks (ANNs) arenumerical methods primarily used to mimic the complex networks of neural connections in the natural brain. Our hypothesis is that an ANNcan be developed that is capable of classifying dental cusps with sufficient accuracy. This bears enormous potential for an application in chairside manufacturing workflows in the dental field, as it closes the gap between digital acquisition of dental geometries and modern computer-aided manufacturing techniques.Three-dimensional surface scans of dental casts representing natural full dental arches were transformed to range image data. These data were processed using an automated algorithm to detect candidates for tooth cusps according to salient geometrical features. These candidates were classified following common dental terminology and used as training data for a tailored ANN.For the actual cusp feature description, two different approaches were developed and applied to the available data: The first uses the relative location of the detected cusps as input data and the second method directly takes the image information given in the range images. In addition, a combination of both was implemented and investigated.Both approaches showed high performance with correct classifications of 93.3% and 93.5%, respectively, with improvements by the combination shown to be minor.This article presents for the first time a fully automated method for the classification of teeththat could be confirmed to work with sufficient precision to exhibit the potential for its use in clinical practice,which is a prerequisite for automated computer-aided planning of prosthetic treatments with subsequent automated chairside manufacturing.

  1. Open and closed-loop control of transonic buffet on 3D turbulent wings using fluidic devices

    NASA Astrophysics Data System (ADS)

    Dandois, Julien; Lepage, Arnaud; Dor, Jean-Bernard; Molton, Pascal; Ternoy, Frédéric; Geeraert, Arnaud; Brunet, Vincent; Coustols, Éric

    2014-06-01

    This paper presents an overview of the work performed recently at ONERA on the control of the buffet phenomenon. This aerodynamic instability induces strong wall pressure fluctuations and as such limits aircraft envelope; consequently, it is interesting to try to delay its onset, in order to enlarge aircraft flight envelop, but also to provide more flexibility during the design phase. Several types of flow control have been investigated, either passive (mechanical vortex generators) or active (fluidic VGs, fluidic trailing-edge device (TED)). It is shown than mechanical and fluidic VGs are able to delay buffet onset in the angle-of-attack domain by suppressing the separation downstream of the shock. The effect of the fluidic TED is different, the separation is not suppressed, but the rear wing loading is increased and consequently the buffet onset is not delayed to higher angles of attack, but only to higher lift coefficient. Then, a closed loop control methodology based on a quasi-static approach is defined and several architectures are tested for various parameters such as the input signal, the objective function or, the tuning of the feedback gain. All closed loop methods are implemented on a dSPACE device calculating in real time the fluidic actuators command from the unsteady pressure sensors data.

  2. FPGA architectures for electronically scanned wide-band RF beams using 3-D FIR/IIR digital filters for rectangular array aperture receivers

    NASA Astrophysics Data System (ADS)

    Wijayaratna, Sewwandi; Madanayake, Arjuna; Beall, Brandon D.; Bruton, Len T.

    2014-05-01

    Real-time digital implementation of three-dimensional (3-D) infinite impulse response (IIR) beam filters are discussed. The 3-D IIR filter building blocks have filter coefficients, which are defined using algebraic closed-form expressions that are functions of desired beam personalities, such as the look-direction of the aperture, the bandwidth and sampling frequency of interest, inter antenna spacing, and 3dB beam size. Real-time steering of such 3-D beam filters are obtained by proposed calculation of filter coefficients. Application specific computing units for rapidly calculating the 3-D IIR filter coefficients at nanosecond speed potentially allows fast real-time tracking of low radar cross section (RCS) objects at close range. Proposed design consists of 3-D IIR beam filter with 4 4 antenna grid and the filter coefficient generation block in separate FPGAs. The hardware is designed and co-simulated using a Xilinx Virtex-6 XC6VLX240T FPGA. The 3-D filter operates over 90 MHz and filter coefficient computing structure can operate at up to 145 MHz.

  3. C-peptide and zinc delivery to erythrocytes requires the presence of albumin: implications in diabetes explored with a 3D-printed fluidic device.

    PubMed

    Liu, Yueli; Chen, Chengpeng; Summers, Suzanne; Medawala, Wathsala; Spence, Dana M

    2015-05-01

    People with type 1 diabetes (T1D) must administer insulin exogenously due to the destruction of their pancreatic β-cells. Endogenous insulin is stored in β-cell granules along with C-peptide, a 31 amino acid peptide that is secreted from these granules in amounts equal to insulin. Exogenous co-administration of C-peptide with insulin has proven to reduce diabetes-associated complications in animals and humans. The exact mechanism of C-peptide's beneficial effects after secretion from the β-cell granules is not completely understood, thus hindering its development as an exogenously administered hormone. Monitoring tissue-to-tissue communication using a 3D-printed microfluidic device revealed that zinc and C-peptide are being delivered to erythrocytes by albumin. Upon delivery, erythrocyte-derived ATP increased by >50%, as did endothelium-derived NO, which was measured downstream in the 3D-printed device. Our results suggest that hormone replacement therapy in diabetes may be improved by exogenous administration of a C-peptide ensemble that includes zinc and albumin.

  4. Translation of First North American 50 and 70 cc Total Artificial Heart Virtual and Clinical Implantations: Utility of 3D Computed Tomography to Test Fit Devices.

    PubMed

    Ferng, Alice S; Oliva, Isabel; Jokerst, Clinton; Avery, Ryan; Connell, Alana M; Tran, Phat L; Smith, Richard G; Khalpey, Zain

    2016-11-10

    Since the creation of SynCardia's 50 cc Total Artificial Hearts (TAHs), patients with irreversible biventricular failure now have two sizing options. Herein, a case series of three patients who have undergone successful 50 and 70 cc TAH implantation with complete closure of the chest cavity utilizing preoperative "virtual implantation" of different sized devices for surgical planning are presented. Computed tomography (CT) images were used for preoperative planning prior to TAH implantation. Three-dimensional (3D) reconstructions of preoperative chest CT images were generated and both 50 and 70 cc TAHs were virtually implanted into patients' thoracic cavities. During the simulation, the TAHs were projected over the native hearts in a similar position to the actual implantation, and the relationship between the devices and the atria, ventricles, chest wall, and diaphragm were assessed. The 3D reconstructed images and virtual modeling were used to simulate and determine for each patient if the 50 or 70 cc TAH would have a higher likelihood of successful implantation without complications. Subsequently, all three patients received clinical implants of the properly sized TAH based on virtual modeling, and their chest cavities were fully closed. This virtual implantation increases our confidence that the selected TAH will better fit within the thoracic cavity allowing for improved surgical outcome. Clinical implantation of the TAHs showed that our virtual modeling was an effective method for determining the correct fit and sizing of 50 and 70 cc TAHs.

  5. VirtoScan - a mobile, low-cost photogrammetry setup for fast post-mortem 3D full-body documentations in x-ray computed tomography and autopsy suites.

    PubMed

    Kottner, Sören; Ebert, Lars C; Ampanozi, Garyfalia; Braun, Marcel; Thali, Michael J; Gascho, Dominic

    2017-03-01

    Injuries such as bite marks or boot prints can leave distinct patterns on the body's surface and can be used for 3D reconstructions. Although various systems for 3D surface imaging have been introduced in the forensic field, most techniques are both cost-intensive and time-consuming. In this article, we present the VirtoScan, a mobile, multi-camera rig based on close-range photogrammetry. The system can be integrated into automated PMCT scanning procedures or used manually together with lifting carts, autopsy tables and examination couch. The VirtoScan is based on a moveable frame that carries 7 digital single-lens reflex cameras. A remote control is attached to each camera and allows the simultaneous triggering of the shutter release of all cameras. Data acquisition in combination with the PMCT scanning procedures took 3:34 min for the 3D surface documentation of one side of the body compared to 20:20 min of acquisition time when using our in-house standard. A surface model comparison between the high resolution output from our in-house standard and a high resolution model from the multi-camera rig showed a mean surface deviation of 0.36 mm for the whole body scan and 0.13 mm for a second comparison of a detailed section of the scan. The use of the multi-camera rig reduces the acquisition time for whole-body surface documentations in medico-legal examinations and provides a low-cost 3D surface scanning alternative for forensic investigations.

  6. Pathology in a tube: Step 1. Fixing, staining, and transporting pancreatic core biopsies in a microfluidic device for 3D imaging

    NASA Astrophysics Data System (ADS)

    Das, Ronnie; Burfeind, Chris W.; Kramer, Greg M.; Seibel, Eric J.

    2014-03-01

    A minimally-invasive diagnosis of pancreatic cancer is accomplished by obtaining a fine needle aspirate and observing the cell preparations under conventional optical microscopy. As an unavoidable artifact, native tissue architecture is lost, making definite diagnosis of malignancy, or invasive neoplasm, impossible. One solution is the preparation of core biopsies (CBs) within a microfluidic device that are subsequently imaged in 3D. In this paper, porcine pancreas CBs (L = 1-2 cm, D = 0.4-2.0 mm) were formalin-fixed, stained and optically cleared (FocusClear®). In brightfield at 40x, light transmission through the ordinarily opaque CBs was increased 5-15x, and internal islet structures were easily identified 250-300 μm beneath the tissue surface. Typically, specimen preparation is time intensive and requires precise handling since CBs are delicate; thus, fixative, absorptive stain and FocusClear® diffusion were done slowly and manually. To significantly speed up tissue processing, we developed a microfluidic device consisting of both a main channel (L = 12.5 cm, D = 1.415 mm) with a circular cross section used for fixing and transporting the CB and an intersecting U-channel employed for staining. Space between the CB and channel wall provided a key feature not traditionally employed in microfluidic devices, such that at low flow rates (5-10 mL/min) CBs were fixed and stained while the specimen remained stationary. By switching quickly to higher flow rates (15-20 mL/min), we could precisely overcome adhesion and transport the specimen within the channel towards the imaging platform for 3D pathology.

  7. 1D versus 3D quantum confinement in 1-5 nm ZnO nanoparticle agglomerations for application in charge-trapping memory devices

    NASA Astrophysics Data System (ADS)

    El-Atab, Nazek; Nayfeh, Ammar

    2016-07-01

    ZnO nanoparticles (NPs) have attracted considerable interest from industry and researchers due to their excellent properties with applications in optoelectronic devices, sunscreens, photocatalysts, sensors, biomedical sciences, etc. However, the agglomeration of NPs is considered to be a limiting factor since it can affect the desirable physical and electronic properties of the N