Science.gov

Sample records for 3he ionization chambers

  1. Fast-Neutron Spectrometry Using a 3He Ionization Chamber and Digital Pulse Shape Analysis

    SciTech Connect

    D. L. Chichester; J. T. Johnson; E. H. Seabury

    2010-05-01

    Digital pulse shape analysis (dPSA) has been used with a Cuttler-Shalev type 3He proportional counter to measure the fast neutron spectra of bare 252Cf and 241AmBe neutron sources. Measurements have also been made to determine the attenuated fast neutron spectra of 252Cf shielded by several materials including water, graphite, liquid nitrogen, magnesium, and tungsten. Rise-time dPSA has been employed using the common rise-time approach for analyzing n +3He ? 1H + 3H ionization events and a new approach has been developed to improve the fidelity of these measurements. Simulations have been performed for the different experimental arrangements and are compared, demonstrating general agreement between the dPSA processed fast neutron spectra and predictions.

  2. Overview of the n3He Experiment and Target Chamber

    NASA Astrophysics Data System (ADS)

    McCrea, Mark; n3He Collaboration

    2017-01-01

    The n3He Experiment aims to measure the parity-violating asymmetry in the direction of proton emission relative to the initial neutron polarization direction in the reaction n-> +3 He -> T + p + 765 keV to a high precision. The size of the asymmetry is estimated to be in the range - 9 . 5 - 2 . 5 ×10-8 , and our goal statistical accuracy is 2 ×10-8 . The experiment ran at the Spallation Neutron Source with data taking completing at the end of 2015. The experiment used a Helium-3 ionization chamber as the combined target and detector. Data analysis is underway and is currently in an advanced stage

  3. IONIZATION CHAMBER

    DOEpatents

    Redman, W.C.; Shonka, F.R.

    1958-02-18

    This patent describes a novel ionization chamber which is well suited to measuring the radioactivity of the various portions of a wire as the wire is moved at a uniform speed, in order to produce the neutron flux traverse pattern of a reactor in which the wire was previously exposed to neutron radiation. The ionization chamber of the present invention is characterized by the construction wherein the wire is passed through a tubular, straight electrode and radiation shielding material is disposed along the wire except at an intermediate, narrow area where the second electrode of the chamber is located.

  4. Ionization chamber

    DOEpatents

    Walenta, Albert H.

    1981-01-01

    An ionization chamber has separate drift and detection regions electrically isolated from each other by a fine wire grid. A relatively weak electric field can be maintained in the drift region when the grid and another electrode in the chamber are connected to a high voltage source. A much stronger electric field can be provided in the detection region by connecting wire electrodes therein to another high voltage source. The detection region can thus be operated in a proportional mode when a suitable gas is contained in the chamber. High resolution output pulse waveforms are provided across a resistor connected to the detection region anode, after ionizing radiation enters the drift region and ionize the gas.

  5. Simulation of ion chamber signals in the n+3 He -> p + t experiment

    NASA Astrophysics Data System (ADS)

    Coppola, Christopher; n3He Collaboration

    2017-01-01

    The parity violating proton directional asymmetry from the capture of polarized neutrons on 3He was measured with a pulsed neutron beam at the Spallation Neutron Source at Oak Ridge National Laboratory. The target is an ion chamber with 3He at 0.476 atmosphere. Signal wires in the chamber have different sensitivities to the physics asymmetry, depdendent on their location and the configuration of the experiment. These geometry factors must be determined by simulation. In addition, simulation estimates the statistical precision of the experiment, optimizes configuration variables, and assists with systematic analysis. To achieve the most accurate simulation of the detector signals, a custom simulation was written in C++ using weighted variables and taking advantage of parallel execution. The phsyics inputs to the simulation came from measurements of the neutron phase space, ENDF cross sections, and PSTAR ionization data. A cell model was applied to combine this physics to produce an accurate simulation of the experimental data. This simulation can be used to calculate accurate and tunable geometry factors, and to produce desired quanities for use in optimization and analysis.

  6. Ionization chamber dosimeter

    DOEpatents

    Renner, Tim R.; Nyman, Mark A.; Stradtner, Ronald

    1991-01-01

    A method for fabricating an ion chamber dosimeter collecting array of the type utilizing plural discrete elements formed on a uniform collecting surface which includes forming a thin insulating layer over an aperture in a frame having surfaces, forming a predetermined pattern of through holes in the layer, plating both surfaces of the layer and simultaneously tilting and rotating the frame for uniform plate-through of the holes between surfaces. Aligned masking and patterned etching of the surfaces provides interconnects between the through holes and copper leads provided to external circuitry.

  7. Ionization-chamber smoke detector system

    DOEpatents

    Roe, Robert F.

    1976-10-19

    This invention relates to an improved smoke-detection system of the ionization-chamber type. In the preferred embodiment, the system utilizes a conventional detector head comprising a measuring ionization chamber, a reference ionization chamber, and a normally non-conductive gas triode for discharging when a threshold concentration of airborne particulates is present in the measuring chamber. The improved system is designed to reduce false alarms caused by fluctuations in ambient temperature. Means are provided for periodically firing the gas discharge triode and each time recording the triggering voltage required. A computer compares each triggering voltage with its predecessor. The computer is programmed to energize an alarm if the difference between the two compared voltages is a relatively large value indicative of particulates in the measuring chamber and to disregard smaller differences typically resulting from changes in ambient temperature.

  8. Liquid-filled ionization chamber temperature dependence

    NASA Astrophysics Data System (ADS)

    Franco, L.; Gómez, F.; Iglesias, A.; Pardo, J.; Pazos, A.; Pena, J.; Zapata, M.

    2006-05-01

    Temperature and pressure corrections of the read-out signal of ionization chambers have a crucial importance in order to perform high-precision absolute dose measurements. In the present work the temperature and pressure dependences of a sealed liquid isooctane filled ionization chamber (previously developed by the authors) for radiotherapy applications have been studied. We have analyzed the thermal response of the liquid ionization chamber in a ˜20C interval around room temperature. The temperature dependence of the signal can be considered linear, with a slope that depends on the chamber collection electric field. For example, a relative signal slope of 0.27×10-2 K-1 for an operation electric field of 1.67×106 V m-1 has been measured in our detector. On the other hand, ambient pressure dependence has been found negligible, as expected for liquid-filled chambers. The thermal dependence of the liquid ionization chamber signal can be parametrized within the Onsager theory on initial recombination. Considering that changes with temperature of the detector response are due to variations in the free ion yield, a parametrization of this dependence has been obtained. There is a good agreement between the experimental data and the theoretical model from the Onsager framework.

  9. Current-voltage characteristic of parallel-plane ionization chamber with inhomogeneous ionization

    NASA Astrophysics Data System (ADS)

    Stoyanov, D. G.

    2007-08-01

    The balances of particles and charges in the volume of parallel-plane ionization chamber are considered. Differential equations describing the distribution of current densities in the chamber volume are obtained. As a result of the differential equations solution an analytical form of the current-voltage characteristic of parallel-plane ionization chamber with inhomogeneous ionization in the volume is obtained.

  10. Ionization Chamber for Prompt Fission Neutron Investigations

    NASA Astrophysics Data System (ADS)

    Zeynalov, Sh.; Zeynalova, O.; Hambsch, F.-J.; Sedyshev, P.; Shvetsov, V.

    In this work we report recent achievements in design of twin back-to-back ionization chamber (TIC) for fission fragment (FF) mass and kinetic energy measurement. Correlated FF kinetic energies, their masses and the angle of FF in respect to the axes in 3D Cartesian coordinates can be determined from analysis of the heights and shapes of the pulses induced by the fission fragments on the anodes of TIC. Anodes of TIC were designed as consisting of isolated strips each having independent electronic circuitry and special multi-channel pulse processing apparatus. Mathematical formulae provided for FF angles measured in respect to the coordinate axes. It was shown how the point of fission fragments origin on the target plane may be determined using the same measured data. The last feature made the TIC a rather powerful tool for prompt fission neutron (PFN) emission investigation in event-by-event analysis of individual fission reactions from non- point fissile source. Position sensitive neutron induced fission detector for neutron-imaging applications with both thermal and low energy neutrons was found as another possible implementation of the designed TIC.

  11. Fundamental Studies of In Situ Plasma Chamber Cleaning Chemistries: C2F6/O2, C3F8/O2, and NF3/He.

    NASA Astrophysics Data System (ADS)

    Entley, William R.; Hennessy, William J.; Langan, John G.

    1999-10-01

    The plasma etching of SiO2 and Si3N4 in C2F6-O2 and C3F8-O2 mixtures has been studied as a function of feed gas composition (SiO2 substrates), pressure (Si3N4 substrates), and power (SiO2 substrates) in a modified commercial RIE chamber. The chamber has been modified to permit in situ electrical measurements, which allows us to correlate the substrate etch rates and power coupling efficiencies to the discharge impedance. In addition, gas-phase FTIR spectroscopy was used to quantify the PFC emissions for the various gas mixtures investigated. For a fixed rf power, pressure, and total gas flow rate, the maximum etch rate of SiO2 was found to occur within a relatively narrow range of oxygen concentrations, centered near a gas composition of 33 mol observed for a wider range of oxygen concentrations in C2F6 based plasmas. Although the destruction efficiency (the percentage of PFC destroyed in the plasma) of C2F6 and C3F8 in O2 based mixtures are comparable under similar operating conditions, significantly larger quantities of plasma generated CF4 are formed in C3F8-O2 gas mixtures. Comparisons are made to NF3/He discharges, which show higher etch rates and higher destruction efficiencies for appropriately chosen operating conditions.

  12. Radiation damage to tetramethylsilane and tetramethylgermanium ionization chambers

    SciTech Connect

    Hoshi, Y.; Higuchi, M.; Oyama, K. . Dept. of Applied Physics)

    1994-08-01

    Two detector media suitable for a warm liquid, ionization chamber filled with tetramethylsilane (TMS) and tetramethylgermanium (TMG) were exposed to [gamma] radiation form a [sup 60]Co source up to dose 579 Gray and 902 Gray, respectively. The electron lifetimes and the free ion yields were measured as a function of accumulated radiation dose. A similar behavior of the electron lifetimes and the free ion yields with increasing radiation does was observed between the TMS and TMG ionization chambers.

  13. RADIATION MONITOR CONTAINING TWO CONCENTRIC IONIZATION CHAMBERS AND MEANS FOR INSULATING THE SEPARATE CHAMBERS

    DOEpatents

    Braestrup, C.B.; Mooney, R.T.

    1964-01-21

    This invention relates to a portable radiation monitor containing two concentric ionization chambers which permit the use of standard charging and reading devices. It is particularly adapted as a personnel x-ray dosimeter and to this end comprises a small thin walled, cylindrical conductor forming an inner energy dependent chamber, a small thin walled, cylindrical conductor forming an outer energy independent chamber, and polymeric insulation means which insulates said chambers from each other and holds the chambers together with exposed connections in a simple, trouble-free, and compact assembly substantially without variation in directional response. (AEC)

  14. Quantification of static magnetic field effects on radiotherapy ionization chambers

    NASA Astrophysics Data System (ADS)

    Agnew, J.; O’Grady, F.; Young, R.; Duane, S.; Budgell, G. J.

    2017-03-01

    Integrated magnetic resonance (MR) imaging and radiotherapy (RT) delivery machines are currently being developed, with some already in clinical use. It is anticipated that the strong magnetic field used in some MR-RT designs will have a significant impact on routine measurements of dose in the MR-linac performed using ionization chambers, which provide traceability back to a primary standard definition of dose. In particular, the presence of small air gaps around ionization chambers may introduce unacceptably high uncertainty into these measurements. In this study, we investigate and quantify the variation attributable to air gaps for several routinely-used cylindrical ionization chambers in a magnetic field, as well as the effect of the magnetic field alone on the response of the chambers. The measurements were performed in a Co-60 beam, while the ionization chambers were positioned in custom-made Perspex phantoms between the poles of an electromagnet, which was capable of generating magnetic fields of up to 2 T field strength, although measurements were focused around 1.5 T. When an asymmetric air gap was rotated at cardinal angles around the ionization chambers investigated here, variation of up to 8.5  ±  0.2 percentage points (PTW 31006 chamber) was observed in an applied magnetic field of 1.5 T. The minimum peak-to-peak variation was 1.1  ±  0.1% (Exradin A1SL). When the same experiment was performed with a well-defined air gap of known position using the PTW 30013 chamber, a variation of 3.8  ±  0.2% was observed. When water was added to the phantom cavity to eliminate all air gaps, the variation for the PTW 30013 was reduced to 0.2  ±  0.01%.

  15. Quantification of static magnetic field effects on radiotherapy ionization chambers.

    PubMed

    Agnew, J; O'Grady, F; Young, R; Duane, S; Budgell, G J

    2017-03-07

    Integrated magnetic resonance (MR) imaging and radiotherapy (RT) delivery machines are currently being developed, with some already in clinical use. It is anticipated that the strong magnetic field used in some MR-RT designs will have a significant impact on routine measurements of dose in the MR-linac performed using ionization chambers, which provide traceability back to a primary standard definition of dose. In particular, the presence of small air gaps around ionization chambers may introduce unacceptably high uncertainty into these measurements. In this study, we investigate and quantify the variation attributable to air gaps for several routinely-used cylindrical ionization chambers in a magnetic field, as well as the effect of the magnetic field alone on the response of the chambers. The measurements were performed in a Co-60 beam, while the ionization chambers were positioned in custom-made Perspex phantoms between the poles of an electromagnet, which was capable of generating magnetic fields of up to 2 T field strength, although measurements were focused around 1.5 T. When an asymmetric air gap was rotated at cardinal angles around the ionization chambers investigated here, variation of up to 8.5  ±  0.2 percentage points (PTW 31006 chamber) was observed in an applied magnetic field of 1.5 T. The minimum peak-to-peak variation was 1.1  ±  0.1% (Exradin A1SL). When the same experiment was performed with a well-defined air gap of known position using the PTW 30013 chamber, a variation of 3.8  ±  0.2% was observed. When water was added to the phantom cavity to eliminate all air gaps, the variation for the PTW 30013 was reduced to 0.2  ±  0.01%.

  16. Segmented ionization chambers for beam monitoring in hadrontherapy

    NASA Astrophysics Data System (ADS)

    Braccini, Saverio; Cirio, Roberto; Donetti, Marco; Marchetto, Flavio; Pittà, Giuseppe; Lavagno, Marco; La Rosa, Vanessa

    2015-05-01

    Segmented ionization chambers represent a good solution to monitor the position, the intensity and the shape of ion beams in hadrontherapy. Pixel and strip chambers have been developed for both passive scattering and active scanning dose delivery systems. In particular, strip chambers are optimal for pencil beam scanning, allowing for spatial and time resolutions below 0.1 mm and 1 ms, respectively. The MATRIX pixel and the Strip Accurate Monitor for Beam Applications (SAMBA) detectors are described in this paper together with the results of several beam tests and industrial developments based on these prototypes.

  17. EML pulse ionization chamber systems for /sup 222/Rn measurements

    SciTech Connect

    Fisenne, I M; Keller, H W

    1985-03-01

    Radon measurements have been performed with pulse ionization chambers at the Environmental Measurements Laboratory (EML) for over 35 years. This report describes the evolution of radon measurement systems, with emphasis on the continuous quality control efforts at EML. 38 refs., 3 figs., 3 tabs.

  18. Ionization chamber gradient effects in nonstandard beam configurations

    SciTech Connect

    Bouchard, Hugo; Seuntjens, Jan; Carrier, Jean-Francois; Kawrakow, Iwan

    2009-10-15

    Purpose: For the purpose of nonstandard beam reference dosimetry, the current concept of reporting absorbed dose at a point in water located at a representative position in the chamber volume is investigated in detail. As new nonstandard beam reference dosimetry protocols are under development, an evaluation of the role played by the definition of point of measurement could lead to conceptual improvements prior to establishing measurement procedures. Methods: The present study uses the current definition of reporting absorbed dose to calculate ionization chamber perturbation factors for two cylindrical chamber models (Exradin A12 and A14) using the Monte Carlo method. The EGSnrc based user-code EGS lowbar chamber is used to calculate chamber dose responses of 14 IMRT beams chosen to cause considerable dose gradients over the chamber volume as previously used by Bouchard and Seuntjens [''Ionization chamber-based reference dosimetry of intensity modulated radiation beams,'' Med. Phys. 31(9), 2454-5465 (2004)]. Results: The study shows conclusively the relative importance of each physical effect involved in the nonstandard beam correction factors of 14 IMRT beams. Of all correction factors involved in the dosimetry of the beams studied, the gradient perturbation correction factor has the highest magnitude, on average, 11% higher compared to reference conditions for the Exradin A12 chamber and about 5% higher for the Extradin A14 chamber. Other perturbation correction factors (i.e., P{sub wall}, P{sub stem}, and P{sub cel}) are, on average, less than 0.8% different from reference conditions for the chambers and beams studied. The current approach of reporting measured absorbed dose at a point in water coinciding with the location of the centroid of the chamber is the main factor responsible for large correction factors in nonstandard beam deliveries (e.g., intensity modulated radiation therapy) reported in literature. Conclusions: To reduce or eliminate the magnitude

  19. Neutron Dosimetry Using a Tissue-Equivalent Ionization Chamber.

    DTIC Science & Technology

    1980-05-01

    procedures are described, and correction factors discussed. /’ On a montg et v~rifiA un systtme de niesure d’oZz la dose ou le kerma tissulaire neutronique ...tube 3.8 cm in diameter. At the same time, it is advantageous to keep the active volume as large as possible in order to maximize sensitivity. The...CHAMBER The construction of the FWT TE Ionization chamber is Illustrated in figure 1. The active volume lies between the central electrode and the

  20. a Liquid Ionization Chamber as Monitor in Radiotherapy

    NASA Astrophysics Data System (ADS)

    Berghöfer, Th.; Engler, J.; Milke, J. M.; Hörandel, J. R.; Hartmann, G. H.

    2006-04-01

    First measurements with a prototype liquid ionization chamber are described to be applied as an online-monitor for intensity modulated radiotherapy. The detector consists of 480 individual electronic channels which allow parallel read-out of radiation induced currents at frequencies exceeding 10 Hz. Dose gradients in the direction of leaf movement of a multileaf collimator have been measured and a reconstruction method for individual leaf positions has been developed. The achieved reconstruction accuracy will be described.

  1. Use of a liquid ionization chamber for stereotactic radiotherapy dosimetry

    NASA Astrophysics Data System (ADS)

    Wagner, A.; Crop, F.; Lacornerie, T.; Vandevelde, F.; Reynaert, N.

    2013-04-01

    Liquid ionization chambers (LICs) offer an interesting tool in the field of small beam dosimetry, allowing better spatial resolution and reduced perturbation effects. However, some aspects remain to be addressed, such as the higher recombination and the effects from the materials of the detector. Our aim was to investigate these issues and their impact. The first step was the evaluation of the recombination effects. Measurements were performed at different SSDs to vary the dose per pulse, and the collection efficiency was obtained. The BEAMnrc code was then used to model the Cyberknife head. Finally, the liquid ionization chamber itself was modelled using the EGSnrc-based code Cavity allowing the evaluation of the influence of the volume and the chamber materials. The liquid ionization charge collection efficiency is approximately 0.98 at 1.5 mGy pulse-1, the highest dose per pulse that we have measured. Its impact on the accuracy of output factors is less than half a per cent. The detector modelling showed a significant contribution from the graphite electrode, up to 6% for the 5 mm collimator. The dependence of the average electronic mass collision stopping power of iso-octane with beam collimation is negligible and thus has no influence on output factor measurements. Finally, the volume effect reaches 5% for the small 5 mm collimator and becomes much smaller (<0.5%) for diameters above 10 mm. LICs can effectively be used for small beam relative dosimetry as long as adequate correction factors are applied, especially for the electrode and volume effects.

  2. Comparison of ionization chamber efficiencies for activity measurements.

    PubMed

    Schrader, H; Svec, A

    2004-01-01

    The calibration of ionization chamber measuring systems in terms of activity is described. The energy-dependent efficiency curves of three chambers at the Bureau International des Poids et Mesures, the National Physical Laboratory and the Physikalisch-Technische Bundesanstalt are determined and compared using a fitting procedure for the experimental radionuclide efficiencies by the Microsoft (MS) EXCEL Solver program. An estimation of the uncertainty of the efficiency curves and the deviations of experimental and calculated radionuclide efficiencies are given. By this fitting method, discrepancies in the efficiency determination can be detected at a level of about one percent. Systematic deviations entering into the calculations either from emission probabilities per decay or from absolute activity standardization are discussed.

  3. Amplitude distribution of ionization jerks in ionization-chamber ASK-1 according long-term measurements

    NASA Astrophysics Data System (ADS)

    Timofeev, Vladislav

    2016-07-01

    As part of the Yakut complex systems by measuring the intensity of cosmic rays has a unique device spherical - ionization chamber ASK-1 with a lead screen thickness of 12 cm. The camera allows you to explore the physical characteristics of the so-called "ionization jerks " - sharp increases ionization current caused by the passage through the device much ionizing particles of cosmic origin. Due to a large increase in current nuclear cascade "showers", formed mainly by particles of cosmic rays in the camera screen. Over the entire period of observation (50 years old) camera ASK-1 was registered 59125 aftershocks. Their nature and properties still does not sufficiently studied, especially in medium and large amplitudes.

  4. Fast-neutron spectrometry using a ³He ionization chamber and digital pulse shape analysis.

    PubMed

    Chichester, D L; Johnson, J T; Seabury, E H

    2012-08-01

    Digital pulse shape analysis (dPSA) has been used with a Cuttler-Shalev type (3)He ionization chamber to measure the fast-neutron spectra of a deuterium-deuterium electronic neutron generator, a bare (252)Cf spontaneous fission neutron source, and of the transmitted fast neutron spectra of a (252)Cf source attenuated by water, graphite, liquid nitrogen, and magnesium. Rise-time dPSA has been employed using the common approach for analyzing n +(3)He→(1)H+(3)H ionization events and improved to account for wall-effect and pile-up events, increasing the fidelity of these measurements. Simulations have been performed of the different experimental arrangements and compared with the measurements, demonstrating general agreement between the dPSA-processed fast-neutron spectra and predictions. The fast-neutron resonance features of the attenuation cross sections of the attenuating materials are clearly visible within the resolution limits of the electronics used for the measurements, and the potential applications of high-resolution fast-neutron spectrometry for nuclear nonproliferation and safeguards measurements are discussed.

  5. Performance of electret ionization chambers in magnetic field.

    PubMed

    Kotrappa, P; Stieff, L R; Mengers, T F; Shull, R D

    2006-04-01

    Electret ionization chambers are widely used for measuring radon and radiation. The radiation measured includes alpha, beta, and gamma radiation. These detectors do not have any electronics and as such can be introduced into magnetic field regions. It is of interest to study the effect of magnetic fields on the performance of these detectors. Relative responses are measured with and without magnetic fields present. Quantitative responses are measured as the magnetic field is varied from 8 kA/m to 716 kA/m (100 to 9,000 gauss). No significant effect is observed for measuring alpha radiation and gamma radiation. However, a significant systematic effect is observed while measuring beta radiation from a 90Sr-Y source. Depending upon the field orientation, the relative response increased from 1.0 to 2.7 (vertical position) and decreased from 1.0 to 0.60 (horizontal position). This is explained as due to the setting up of a circular motion for the electrons by the magnetic field, which may increase or decrease the path length in air depending upon the experimental configuration. It is concluded that these ionization chambers can be used for measuring alpha (and hence radon) and gamma radiation in the range of magnetic fields studied. However, caution must be exercised if measuring beta radiation.

  6. Analytical form of current-voltage characteristic of parallel-plane, cylindrical and spherical ionization chambers with homogeneous ionization

    NASA Astrophysics Data System (ADS)

    Stoyanov, D. G.

    2007-11-01

    The elementary processes taking place in the formation of charged particles and their flow in parallel-plane, cylindrical and spherical geometry cases of ionization chamber are considered. On the basis of particles and charges balance a differential equation describing the distribution of current densities in the ionization chamber volume is obtained. As a result of the differential equation solution an analytical form of the current-voltage characteristic of an ionization chamber with homogeneous ionization is obtained. For the parallel-plane case comparision with experimental data is performed.

  7. An automated ionization chamber for secondary radioactivity standards.

    PubMed

    Fitzgerald, R

    2010-01-01

    I report on the operation and characterization of a new ionization chamber system, "AUTOIC", featuring a commercial digital electrometer and a commercial robotic sample changer. The relative accuracy of the electrometer was improved significantly beyond the manufacturer's specifications through an in-house calibration of the various ranges, applied via software. The measurement precision and repeatability of the system have been determined by measuring multiple samples of the same radionuclide over the span of two or three years. The linearity of the system was examined by following the decay of (99m)Tc, (99)Mo and (133)Xe sources for up to 19 half-lives and determining half-life values. All of these values agree with the accepted literature values, within their combined uncertainties.

  8. A multiwire ionization chamber readout circuit using current mirrors

    NASA Astrophysics Data System (ADS)

    Rawnsley, W. R.; Smith, D.; Moskven, T.

    1997-01-01

    A circuit which utilizes current mirrors has been used to apply high voltage bias to the wires of a multiwire ionization chamber (MWIC) profile monitor while still allowing measurement of the beam-induced ion-electron currents collected on the wires. Bias voltages of up to 250 V have been used while wire currents over a range of 0.5 nA to 50 nA have been measured. The circuit is unipolar but can be designed for positive or negative bias. The mirrors also provide a current gain of 10, reducing the effects of transistor leakage and extending the useful range of the circuit to lower signal levels. A module containing 32 Wilson current mirrors has been constructed and is used with a MWIC monitor in TRIUMF's Parity experiment beamline.

  9. NIST Ionization Chamber "A" Sample-Height Corrections.

    PubMed

    Fitzgerald, Ryan

    2012-01-01

    For over 30 years scientists in the NIST radioactivity group have been using their pressurized ionization chamber "A" (PIC "A") to make measurements of radioactivity and radioactive half-lives. We now have evidence that some of those reported measurements were incorrect due to slippage of the source positioning ring over time. The temporal change in the holder caused an error in the source-height within the chamber, which was thought to be invariant. This unaccounted-for height change caused a change in the detector response and thus a relative error in measured activity on the order of 10(-5) to 10(-3) per year, depending on the radionuclide. The drifting detector response affected calibration factors and half-life determinations. After discovering the problem, we carried out historic research and new sensitivity tests. As a result, we have created a quantitative model of the effect and have used that model to estimate corrections to some of the past measurement results from PIC "A". In this paper we report the details and results of that model. Meanwhile, we have fixed the positioning ring and are recalibrating the detector using primary measurement methods and enhanced quality control measures.

  10. A well-type ionization chamber geometric correction factor

    NASA Astrophysics Data System (ADS)

    Meiler, R. J.; Sibata, C. H.; Ho, A. K.; de Souza, C.; Shin, K. H.

    1996-07-01

    To correct for the influence of source configuration on the measured activity of spherical and cylindrical brachytherapy sources, a geometric correction factor was calculated for the Standard Imaging HDR-1000 well-type ionization chamber. A Fortran program modelled each source as a lattice of point sources. Because of the cylindrical symmetry of the well chamber, it could be uniquely modelled by point detectors along the perimeter of the radial plane of the detection volume. Path lengths were calculated and attenuation factors were applied to each source - detector point combination individually. The total dose rate at each detection point was found through a Sievert summation of the point source contributions. For sources with identical activities, a correction factor of was calculated, equal to the ratio of the dose rate of the cylindrical source to that of the sphere. Experimental verification using a Nuclear Associates 67-809 series cylindrical source and an Amersham spherical source yielded a correction factor of .

  11. Polarity correction factor for flattening filter free photon beams in several cylindrical ionization chambers.

    PubMed

    Ogata, Toshiyuki; Uehara, Kazuyuki; Nakayama, Masao; Tsudou, Shinji; Masutani, Takashi; Okayama, Takanobu

    2016-07-01

    In this study, we aimed to compare the polarity correction factor in ionization chambers for flattening filter free (FFF) photon beams and flattening filter (FF) beams. Measurements were performed with both 6 and 10 MV FFF and FF beams. Five commercial ionization chambers were evaluated: PTW TN30013; IBA Dosimetry CC01, CC04, and CC13; and Exradin A12S. Except for the CC01 ionization chamber, the other four chambers showed less than a 0.3 % difference in the polarity effect between the FFF and the FF beams. The CC01 chamber showed a strong field-size-dependence, unlike the other chambers. The polarity effect for all chambers with FFF beams did not change with the dose rate. Except in the case of the CC01 chamber, the difference in the polarity effect between FFF and FF beams was not significant.

  12. Evaluation of Gas-filled Ionization Chamber Method for Radon Measurement at Two Reference Facilities

    SciTech Connect

    Ishikawa, Tetsuo; Tokonami, Shinji; Kobayashi, Yosuke; Sorimachi, Atsuyuki; Yatabe, Yoshinori; Miyahara, Nobuyuki

    2008-08-07

    For quality assurance, gas-filled ionization chamber method was tested at two reference facilities for radon calibration: EML (USA) and PTB (Germany). Consequently, the radon concentrations estimated by the ionization chamber method were in good agreement with the reference radon concentrations provided by EML as well as PTB.

  13. Investigation of electric field distribution on FAC-IR-300 ionization chamber

    NASA Astrophysics Data System (ADS)

    Mohammadi, S. M.; Tavakoli-Anbaran, H.; Zeinali, H. Z.

    2016-07-01

    One of the important parameters for establishing charge particle equilibrium (CPE) conditions of free-air ionization chamber is an electric field distribution. In this paper, electric field distribution inside the ionization chamber was investigated by finite element method. For this purpose, the effects of adding guard plate and guard strips on the electric field distribution in the ionization chamber were studied. it is necessary to apply a lead box around the ionization chamber body to avoid of scattered radiation effects on the ionization chamber operation, but the lead box changes the electric field distribution. In the following, the effect of lead box on the electric field distribution was studied. Finally, electric field distribution factor (kfield) was calculated by the simulation. The results of the simulation showed that presence of the guard plate and guard strips, and applying a suitable potential to lead box, a convergence of kfield to 1 was achieved.

  14. Cross sections of electron capture and electron capture with ionization of argon atoms by fast 3He2+ ions at various impact parameters

    NASA Astrophysics Data System (ADS)

    Afrosimov, V. V.; Basalaev, A. A.; Panov, M. N.

    2017-01-01

    The absolute differential cross sections of scattering of fast particles formed in processes with capture of one or two electrons from Ar atoms have been measured for 6-keV He2+ ions in the interval of scattering angles within 0°-2.5°. The cross sections of electron capture and electron capture with ionization have been determined as functions of the impact parameter. The probabilities of these processes are compared to the distribution of electron density in various shells of target atoms. Applicability of the models of screened Coulomb interaction potentials to description of the scattering of recharged particles is assessed.

  15. Monte Carlo calculation of energy deposition in ionization chambers for tritium measurements

    NASA Astrophysics Data System (ADS)

    Zhilin, Chen; Shuming, Peng; Dan, Meng; Yuehong, He; Heyi, Wang

    2014-10-01

    Energy deposition in ionization chambers for tritium measurements has been theoretically studied using Monte Carlo code MCNP 5. The influence of many factors, including carrier gas, chamber size, wall materials and gas pressure, has been evaluated in the simulations. It is found that β rays emitted by tritium deposit much more energy into chambers flowing through with argon than with deuterium in them, as much as 2.7 times higher at pressure 100 Pa. As chamber size gets smaller, energy deposition decreases sharply. For an ionization chamber of 1 mL, β rays deposit less than 1% of their energy at pressure 100 Pa and only 84% even if gas pressure is as high as 100 kPa. It also indicates that gold plated ionization chamber results in the highest deposition ratio while aluminum one leads to the lowest. In addition, simulations were validated by comparison with experimental data. Results show that simulations agree well with experimental data.

  16. On line high dose static position monitoring by ionization chamber detector for industrial gamma irradiators.

    PubMed

    Rodrigues, Ary A; Vieira, Jose M; Hamada, Margarida M

    2010-01-01

    A 1 cm(3) cylindrical ionization chamber was developed to measure high doses on line during the sample irradiation in static position, in a (60)Co industrial plant. The developed ionization chamber showed to be suitable for use as a dosimeter on line. A good linearity of the detector was found between the dose and the accumulated charge, independently of the different dose rates caused by absorbing materials.

  17. Construction of an ionization chamber for the measurement of dose of low energy x-rays

    SciTech Connect

    Perez, Y. B. Alcantara; Jimenez, F. J. Ramirez

    2008-08-11

    We designed and constructed the prototype of an ionization chamber to measure the dose of an X-ray tube with Molybdenum anode. This X-ray tube is located in the Physics department at CINVESTAV and is used for medical physics purposes in the imaging area. The ionization chamber is designed to measure doses on biological samples exposed to X-rays and will be applied in radiation protection studies.

  18. Pencil beam proton radiography using a multilayer ionization chamber

    NASA Astrophysics Data System (ADS)

    Farace, Paolo; Righetto, Roberto; Meijers, Arturs

    2016-06-01

    A pencil beam proton radiography (PR) method, using a commercial multilayer ionization chamber (MLIC) integrated with a treatment planning system (TPS) was developed. A Giraffe (IBA Dosimetry) MLIC (±0.5 mm accuracy) was used to obtain pencil beam PR by delivering spots uniformly positioned at a 5.0 mm distance in a 9  ×  9 square of spots. PRs of an electron-density (with tissue-equivalent inserts) phantom and a head phantom were acquired. The integral depth dose (IDD) curves of the delivered spots were computed by the TPS in a volume of water simulating the MLIC, and virtually added to the CT at the exit side of the phantoms. For each spot, measured and calculated IDD were overlapped in order to compute a map of range errors. On the head-phantom, the maximum dose from PR acquisition was estimated. Additionally, on the head phantom the impact on the range errors map was estimated in case of a 1 mm position misalignment. In the electron-density phantom, range errors were within 1 mm in the soft-tissue rods, but greater in the dense-rod. In the head-phantom the range errors were  -0.9  ±  2.7 mm on the whole map and within 1 mm in the brain area. On both phantoms greater errors were observed at inhomogeneity interfaces, due to sensitivity to small misalignment, and inaccurate TPS dose computation. The effect of the 1 mm misalignment was clearly visible on the range error map and produced an increased spread of range errors (-1.0  ±  3.8 mm on the whole map). The dose to the patient for such PR acquisitions would be acceptable as the maximum dose to the head phantom was  <2cGyE. By the described 2D method, allowing to discriminate misalignments, range verification can be performed in selected areas to implement an in vivo quality assurance program.

  19. Performances of a VLSI wide dynamic range current-to-frequency converter for strip ionization chambers

    NASA Astrophysics Data System (ADS)

    Bonazzola, G. C.; Cirio, R.; Donetti, M.; Marchetto, F.; Mazza, G.; Peroni, C.; Zampieri, A.

    1998-02-01

    In this paper we report on the design and test of a 14-channel VLSI chip to perform the current to frequency conversion for parallel plate strip ionization chambers. The chambers measure the intensity and the geometrical characteristics of a therapeutical beam.

  20. Polarity and ion recombination corrections in continuous and pulsed beams for ionization chambers with high Z chamber walls.

    PubMed

    Aldosary, Ghada; Safigholi, Habib; Song, William; Seuntjens, Jan; Sarfehnia, Arman

    2017-03-01

    In this work, the response of Farmer-type ionization chambers fitted with high atomic number (Z) walls is studied, and results of the effects of such walls on polarity and ion recombination correction factors in both continuous and pulsed beams are presented. Measurements were made in a continuous Co-60 beam and a pulsed 6MV linac beam using an Exradin-A12 ionization chamber fitted with the manufacturer's C-552 plastic wall, as well as geometrically identical walls made from aluminum, copper and molybdenum. The bias voltage was changed between 10values (range: +50 to +560V). Ion recombination was determined from Jaffé plots and by using the "two-voltage technique". The saturation charge measured with each chamber wall was extrapolated from Jaffé plots. Additionally, the effect of different wall materials on chamber response was studied using MCNP simulations. Results showed that the polarity correction factor is not significantly affected by changes in chamber wall material (within 0.1%). Furthermore, although the saturation charges greatly vary with each chamber wall material, and charge multiplication increases for higher atomic number wall materials, the standard methods of calculating ion recombination yielded results that differed by only 0.2%. Therefore, polarity and ion recombination correction factors are not greatly affected by the chamber wall material. The experimental saturation charges for all the different wall materials agreed well within the uncertainty with MCNP simulations. The breakdown of the linear relationship in Jaffé plots that was previously reported to exist for conventional chamber walls was also observed with the different wall materials.

  1. The 3He Supply Problem

    SciTech Connect

    Kouzes, Richard T.

    2009-05-01

    One of the main uses for 3He is in gas proportional counters for neutron detection. Radiation portal monitors deployed for homeland security and non-proliferation use such detectors. Other uses of 3He are for research detectors, commercial instruments, well logging detectors, dilution refrigerators, for targets or cooling in nuclear research, and for basic research in condensed matter physics. The US supply of 3He comes almost entirely from the decay of tritium used in nuclear weapons by the US and Russia. A few other countries contribute a small amount to the world’s 3He supply. Due to the large increase in use of 3He for homeland security, the supply has dwindled, and can no longer meet the demand. This white paper reviews the problems of supply, utilization, and alternatives.

  2. Development of a 3He-hydraulic actuator for spin pump in superfluid 3He-A1

    NASA Astrophysics Data System (ADS)

    Yamaguchi, A.; Wada, M.; Tanaka, H.; Motoyama, G.; Sumiyama, A.; Aoki, Y.; Okuda, Y.; Murakawa, S.; Karaki, Y.; Kubota, M.; Kojima, H.

    2012-12-01

    The superfluid 3He A1 phase contains a spin-polarized condensate. This property allows novel superfluid spin current experiments. In the mechano-spin effect of the A1 phase a mechanically applied pressure gradient and a superleak-spin filter enable to directly boost spin polarization of 3He in a small chamber. Using a flexible membrane as an electrostatically actuated pump, we carried out such experiments and observed 50% enhancement of spin density. Here we report on a new 3He-hydraulic actuator for achieving greater enhancement of spin density. The actuator consists of two liquid 3He chambers located at a 4.2 K plate and in the interior of the cell. The pressure in the 4.2 K chamber is heater-controlled and it transmits a force onto a membrane in the cell. The motion of the membrane induces spin-polarized current into an accumulation chamber.

  3. Absolute dosimetry on a dynamically scanned sample for synchrotron radiotherapy using graphite calorimetry and ionization chambers

    NASA Astrophysics Data System (ADS)

    Lye, J. E.; Harty, P. D.; Butler, D. J.; Crosbie, J. C.; Livingstone, J.; Poole, C. M.; Ramanathan, G.; Wright, T.; Stevenson, A. W.

    2016-06-01

    The absolute dose delivered to a dynamically scanned sample in the Imaging and Medical Beamline (IMBL) on the Australian Synchrotron was measured with a graphite calorimeter anticipated to be established as a primary standard for synchrotron dosimetry. The calorimetry was compared to measurements using a free-air chamber (FAC), a PTW 31 014 Pinpoint ionization chamber, and a PTW 34 001 Roos ionization chamber. The IMBL beam height is limited to approximately 2 mm. To produce clinically useful beams of a few centimetres the beam must be scanned in the vertical direction. In practice it is the patient/detector that is scanned and the scanning velocity defines the dose that is delivered. The calorimeter, FAC, and Roos chamber measure the dose area product which is then converted to central axis dose with the scanned beam area derived from Monte Carlo (MC) simulations and film measurements. The Pinpoint chamber measures the central axis dose directly and does not require beam area measurements. The calorimeter and FAC measure dose from first principles. The calorimetry requires conversion of the measured absorbed dose to graphite to absorbed dose to water using MC calculations with the EGSnrc code. Air kerma measurements from the free air chamber were converted to absorbed dose to water using the AAPM TG-61 protocol. The two ionization chambers are secondary standards requiring calibration with kilovoltage x-ray tubes. The Roos and Pinpoint chambers were calibrated against the Australian primary standard for air kerma at the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA). Agreement of order 2% or better was obtained between the calorimetry and ionization chambers. The FAC measured a dose 3-5% higher than the calorimetry, within the stated uncertainties.

  4. Absolute dosimetry on a dynamically scanned sample for synchrotron radiotherapy using graphite calorimetry and ionization chambers.

    PubMed

    Lye, J E; Harty, P D; Butler, D J; Crosbie, J C; Livingstone, J; Poole, C M; Ramanathan, G; Wright, T; Stevenson, A W

    2016-06-07

    The absolute dose delivered to a dynamically scanned sample in the Imaging and Medical Beamline (IMBL) on the Australian Synchrotron was measured with a graphite calorimeter anticipated to be established as a primary standard for synchrotron dosimetry. The calorimetry was compared to measurements using a free-air chamber (FAC), a PTW 31 014 Pinpoint ionization chamber, and a PTW 34 001 Roos ionization chamber. The IMBL beam height is limited to approximately 2 mm. To produce clinically useful beams of a few centimetres the beam must be scanned in the vertical direction. In practice it is the patient/detector that is scanned and the scanning velocity defines the dose that is delivered. The calorimeter, FAC, and Roos chamber measure the dose area product which is then converted to central axis dose with the scanned beam area derived from Monte Carlo (MC) simulations and film measurements. The Pinpoint chamber measures the central axis dose directly and does not require beam area measurements. The calorimeter and FAC measure dose from first principles. The calorimetry requires conversion of the measured absorbed dose to graphite to absorbed dose to water using MC calculations with the EGSnrc code. Air kerma measurements from the free air chamber were converted to absorbed dose to water using the AAPM TG-61 protocol. The two ionization chambers are secondary standards requiring calibration with kilovoltage x-ray tubes. The Roos and Pinpoint chambers were calibrated against the Australian primary standard for air kerma at the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA). Agreement of order 2% or better was obtained between the calorimetry and ionization chambers. The FAC measured a dose 3-5% higher than the calorimetry, within the stated uncertainties.

  5. Theoretical study of energy deposition in ionization chambers for tritium measurements

    SciTech Connect

    Chen, Zhilin; Peng, Shuming; Meng, Dan; He, Yuehong; Wang, Heyi

    2013-10-15

    Energy deposition in ionization chambers has been theoretically studied for tritium measurements in gaseous form. A one-dimension model is introduced to establish the quantitative relationship between energy deposition rate and many factors, including carrier gas, gas pressure, wall material, chamber size, and gas temperature. Energy deposition rate has been calculated at pressure varying from 5 kPa to 500 kPa based on some approximations. It is found that energy deposition rate varies greatly for different parameters, especially at low gas pressure. For the same chamber, energy deposition rate in argon is much higher than in deuterium, as much as 70.7% higher at 5 kPa. Gold plated chamber gives highest energy deposition rate in the calculations while aluminum chamber results in the lowest. As chamber size gets smaller, β ray emitted by tritium will deposit less energy in the sensitive region of the chamber. For chambers flowing through with the same gas, energy deposition rate in a 10 L chamber is 23.9% higher than in a 0.05 L chamber at 5 kPa. Gas temperature also places slight influence on energy deposition rate, and 373 K will lead to 6.7% lower deposition rate than 233 K at 5 kPa. In addition, experiments have been performed to obtain energy deposition rate in a gold plated chamber, which show good accordance with theoretical calculations.

  6. Theoretical study of energy deposition in ionization chambers for tritium measurements

    NASA Astrophysics Data System (ADS)

    Chen, Zhilin; Peng, Shuming; Meng, Dan; He, Yuehong; Wang, Heyi

    2013-10-01

    Energy deposition in ionization chambers has been theoretically studied for tritium measurements in gaseous form. A one-dimension model is introduced to establish the quantitative relationship between energy deposition rate and many factors, including carrier gas, gas pressure, wall material, chamber size, and gas temperature. Energy deposition rate has been calculated at pressure varying from 5 kPa to 500 kPa based on some approximations. It is found that energy deposition rate varies greatly for different parameters, especially at low gas pressure. For the same chamber, energy deposition rate in argon is much higher than in deuterium, as much as 70.7% higher at 5 kPa. Gold plated chamber gives highest energy deposition rate in the calculations while aluminum chamber results in the lowest. As chamber size gets smaller, β ray emitted by tritium will deposit less energy in the sensitive region of the chamber. For chambers flowing through with the same gas, energy deposition rate in a 10 L chamber is 23.9% higher than in a 0.05 L chamber at 5 kPa. Gas temperature also places slight influence on energy deposition rate, and 373 K will lead to 6.7% lower deposition rate than 233 K at 5 kPa. In addition, experiments have been performed to obtain energy deposition rate in a gold plated chamber, which show good accordance with theoretical calculations.

  7. Dosimetric characterization of a large area pixel-segmented ionization chamber.

    PubMed

    Amerio, S; Boriano, A; Bourhaleb, F; Cirio, R; Donetti, M; Fidanzio, A; Garelli, E; Giordanengo, S; Madon, E; Marchetto, F; Nastasi, U; Peroni, C; Piermattei, A; Sanz Freire, C J; Sardo, A; Trevisiol, E

    2004-02-01

    A pixel-segmented ionization chamber has been designed and built by Torino University and INFN. The detector features a 24 x 24 cm2 active area divided in 1024 independent cylindrical ionization chambers and can be read out in 500 micros without introducing dead time; the digital charge quantum can be adjusted between 100 fC and 800 fC. The sensitive volume of each single ionization chamber is 0.07 cm3. The purpose of the detector is to ease the two-dimensional (2D) verifications of fields with complex shapes and large gradients. The detector was characterized in a PMMA phantom using 60Co and 6 MV x-ray photon beams. It has shown good signal linearity with respect to dose and dose rate to water. The average sensitivity of a single ionization chamber was 2.1 nC/Gy, constant within 0.5% over one month of daily measurements. Charge collection efficiency was 0.985 at the operating polarization voltage of 400 V and 3.5 Gy/min dose rate. Tissue maximum ratio and output factor have been compared with a Farmer ionization chamber and were found in good agreement. The dose profiles have been compared with the ones obtained with an ionization chamber in water phantom for the field sizes supplied by a 3D-Line dynamic multileaf collimator. These results show that this detector can be used for 2D dosimetry of x-ray photon beams, supplying a good spatial resolution and sensibly reducing the time spent in dosimetric verification of complex radiation fields.

  8. Nuclear signal simulation applied to gas ionizing chambers

    SciTech Connect

    Coulon, Romain; Dumazert, Jonathan

    2015-07-01

    Particle transport codes used in detector simulation allow the calculation of the energy deposited by charged particles produced following an interaction. The pulses temporal shaping is more and more used in nuclear measurement into pulse shape analysis techniques. A model is proposed in this paper to simulate the pulse temporal shaping and the associated noise level thanks to the output track file PTRAC provides by Monte-Carlo particle transport codes. The model has been dedicated to ion chambers and more especially for High Pressure Xenon chambers HPXe where the pulse shape analysis can resolve some issues regarding with this technology as the ballistic deficit phenomenon. The model is fully described and an example is presented as a validation of such full detector simulation. (authors)

  9. An improved leakage current compensation technique for a 4πγ ionization chamber system

    NASA Astrophysics Data System (ADS)

    Hino, Y.; Kawada, Y.; Nazaroh

    1996-02-01

    A current integration method using a small capacitor is most commonly employed for precise measurements of small currents from 4πγ ionization chambers for the secondary standardization of radionuclides. An improved technique has been developed for eliminating the possible effect due to the electrical leakage and/or current loss across the feedback capacitor used in the integration of the ionization current. This method is based upon charge integration from a fixed negative level of potential to nearly the same level of positive potential via the zero point. The validity of this method is demonstrated for some typical applications of 4πγ ionization chamber systems. This technique can contribute to the improvement of accuracy and to the extension of the intensity range of radioactive source in 4πγ ionization measurement.

  10. Determination of (137)Cs half-life with an ionization chamber.

    PubMed

    Juget, Frédéric; Nedjadi, Youcef; Buchillier, Thierry; Bochud, François; Bailat, Claude

    2016-12-01

    The half-life of (137)Cs was measured with an ionization chamber by following the decay of 5 sources over a 30 years period between 1983 and 2013. The ratio between the ionization chamber current for the cesium sources and (226)Ra source was used for the half-life calculation. The value found for the (137)Cs half-life is 10,955.2±10.7 days, where the uncertainty evaluation combines type A and B for one standard deviation.

  11. Update of NIST half-life results corrected for ionization chamber source-holder instability.

    PubMed

    Unterweger, M P; Fitzgerald, R

    2014-05-01

    As reported at the ICRM 2011, it was discovered that the source holder used for calibrations in the NIST 4πγ ionization chamber (IC) was not stable. This has affected a large number of half-life measurement results previously reported and used in compilations of nuclear data. Corrections have been made on all of the half-life data based on the assumption that the changes to the ionization chamber response were gradual. The corrections are energy dependent and therefore radionuclide specific. This presentation will review our results and present the recommended changes in half-life values and/or uncertainties.

  12. Construction of a fast ionization chamber for high-rate particle identification

    NASA Astrophysics Data System (ADS)

    Chae, K. Y.; Ahn, S.; Bardayan, D. W.; Chipps, K. A.; Manning, B.; Pain, S. D.; Peters, W. A.; Schmitt, K. T.; Smith, M. S.; Strauss, S. Y.

    2014-07-01

    A new gas-filled ionization chamber for high count rate particle identification has been constructed and commissioned at the Holifield Radioactive Ion Beam Facility (HRIBF) at Oak Ridge National Laboratory (ORNL). To enhance the response time of the ionization chamber, a design utilizing a tilted entrance window and tilted electrodes was adopted, which is modified from an original design by Kimura et al. [1]. A maximum counting rate of 700 , 000 particles per second has been achieved. The detector has been used for several radioactive beam measurements performed at the HRIBF.

  13. Design of ionization chambers for use in teaching x-ray dosimetry

    NASA Astrophysics Data System (ADS)

    Ross, Joseph

    Ionization chambers are one of the most commonly used radiation detectors in radiation dosimetry. In this project, nine ionization chambers were constructed for use in teaching radiation dosimetry to students of health physics, medical physics, nuclear engineering, and related disciplines. The components of these detectors such as detector wall composition, type of electrode, type of leakage current guard ring, fill gas pressure, and interior conducting material differ in a systematic way to show that various parameters of ionization chamber design can affect the response of the detectors. Each of these variables was investigated using an 80 keV x-ray machine to determine detector response in terms of absorbed dose, HVL, polarity, and operating voltage. Of the components studied, wall thickness and composition was found to be the most sensitive variable. The pressure inside the chamber did have a significant effect on the amount of charge collected and the absorbed dose. The leakage current guard ring was not a critical component for this ionization chamber design.

  14. Pulse mode readout techniques for use with non-gridded industrial ionization chambers

    SciTech Connect

    Popov, Vladimir E.; Degtiarenko, Pavel V.

    2011-10-01

    Highly sensitive readout technique for precision long-term radiation measurements has been developed and tested in the Radiation Control Department at Jefferson Lab. The new electronics design is used to retrieve ionization data in a pulse mode. The dedicated data acquisition system works with M=Audio Audiophile 192 High-Definition 24-bit/192 kHz audio cards, taking data in continuous waveform recording mode. The on-line data processing algorithms extract signals of the ionization events from the data flow and measure the ionization value for each event. Two different ion chambers are evaluated. The first is a Reuter-Stokes Argon-filled (at 25 atm) High Pressure Ionization Chamber (HPIC), commonly used as a detector part in many GE Reuter-Stokes instruments of the RSS series. The second is a VacuTec Model 70181, 5 atm Xenon-filled ionization chamber. Results for both chambers indicate that the techniques allow using industrial ICs for high sensitivity and precision long-term radiation measurements, while at the same time providing information about spectral characteristics of the radiation fields.

  15. A magnetically levitated electrode ionization chamber of the noncontact measurement type

    NASA Astrophysics Data System (ADS)

    Kawaguchi, Toshiro; Yoshimura, Atsushi

    2002-04-01

    A new type of ionization chamber with levitated electrode has been developed. In this ionization chamber, an ion-collection electrode levitates in the air without getting any physical support from the insulator. The electrode is charged by an electrostatic charger without physical contact. The charge of the electrode is read out at a Faraday cage periodically at a given time interval without physical contact. Because its electrode levitates, the ionization chamber produces no background current caused by leaks or piezo current. In addition, as the charging of its electrode and the read-out of its charge are carried out without physical contact, no irregular charge or contact potential difference due to the chattering between electrode and contact point occurs. Through experiments, it was found that this ionization chamber was able to measure the γ-ray dose such as the environmental radiation with a high degree of sensitivity. The minimum detectable value of ionization current when accumulated for 1 h is about 1.3×10 -17 A.

  16. Development of 10B-Based 3He Replacement Neutron Detectors

    NASA Astrophysics Data System (ADS)

    King, Michael J.; Gozani, Tsahi; Hilliard, Donald B.

    2011-12-01

    Radiation portal monitors (RPM) are currently deployed at United States border crossings to passively inspect vehicles and persons for any emission of neutrons and/or gamma rays, which may indicate the presence of unshielded nuclear materials. The RPM module contains an organic scintillator with 3He proportional counters to detect gamma rays and thermalized neutrons, respectively. The supply of 3He is rapidly dwindling, requiring alternative detectors to provide the same function and performance. Our alternative approach is one consisting of a thinly-coated 10B flat-panel ionization chamber neutron detector that can be deployed as a direct drop-in replacement for current RPM 3He detectors. The uniqueness of our approach in providing a large-area detector is in the simplicity of construction, scalability of the unit cell detector, ease of adaptability to a variety of applications and low cost. Currently, Rapiscan Laboratories and Helicon Thin Film Systems have designed and developed an operational 100 cm2 multi-layer prototype 10BB-based ionization chamber.

  17. Determination of relative ion chamber calibration coefficients from depth-ionization measurements in clinical electron beams

    NASA Astrophysics Data System (ADS)

    Muir, B. R.; McEwen, M. R.; Rogers, D. W. O.

    2014-10-01

    A method is presented to obtain ion chamber calibration coefficients relative to secondary standard reference chambers in electron beams using depth-ionization measurements. Results are obtained as a function of depth and average electron energy at depth in 4, 8, 12 and 18 MeV electron beams from the NRC Elekta Precise linac. The PTW Roos, Scanditronix NACP-02, PTW Advanced Markus and NE 2571 ion chambers are investigated. The challenges and limitations of the method are discussed. The proposed method produces useful data at shallow depths. At depths past the reference depth, small shifts in positioning or drifts in the incident beam energy affect the results, thereby providing a built-in test of incident electron energy drifts and/or chamber set-up. Polarity corrections for ion chambers as a function of average electron energy at depth agree with literature data. The proposed method produces results consistent with those obtained using the conventional calibration procedure while gaining much more information about the behavior of the ion chamber with similar data acquisition time. Measurement uncertainties in calibration coefficients obtained with this method are estimated to be less than 0.5%. These results open up the possibility of using depth-ionization measurements to yield chamber ratios which may be suitable for primary standards-level dissemination.

  18. Development of a pixel ionization chamber for beam monitor in proton therapy

    NASA Astrophysics Data System (ADS)

    La Rosa, A.; Garella, M. A.; Attili, A.; Bourhaleb, F.; Cirio, R.; Donetti, M.; Giordanengo, S.; Givehchi, N.; Marchetto, F.; Mazza, G.; Meyroneinc, S.; Pecka, A.; Peroni, C.; Pittà, G.

    2007-03-01

    We have developed a detector to be used as monitor for proton therapy beam lines. The detector is a 2-D parallel plate ionization chamber, with the anode segmented in 1024 square pixels arranged in a 32×32 matrix. The detector characterization is presented.

  19. Absorbed dose dependence of the correction factors for ionization chamber cable irradiation effects.

    PubMed

    Campos, L L; Caldas, L V

    1991-03-01

    A simple method was developed, for possible use by hospital physicists, to evaluate the irradiation effects on cables and connectors during large-radiation-field dosimetry with ionization chambers and to determine correction factors for the used system or geometry. This method was based on the absorbed dose dependence of the correction factor.

  20. A VLSI analog pipeline read-out for electrode segmented ionization chambers

    NASA Astrophysics Data System (ADS)

    Bonazzola, G. C.; Bouvier, S.; Cirio, R.; Donetti, M.; Figus, M.; Marchetto, F.; Peroni, C.; Pernigotti, E.; Thenard, J. M.; Zampieri, A.

    1999-05-01

    We report on the design and test of a 32-channel VLSI chip based on the analog pipeline memory concept. The charge from a strip of a ionization chamber, is stored as a function of time in a switched capacitor array. The cell reading can be done in parallel with the writing.

  1. 3He on preplated graphite

    NASA Astrophysics Data System (ADS)

    Gordillo, M. C.; Boronat, J.

    2016-10-01

    By using the diffusion Monte Carlo method, we obtained the full phase diagram of 3He on top of graphite preplated with a solid layer of 4He. All the 4He atoms of the substrate were explicitly considered and allowed to move during the simulation. We found that the ground state is a liquid of density 0.007 ±0.001 Å-2, in good agreement with available experimental data. This is significantly different from the case of 3He on clean graphite, in which both theory and experiment agree on the existence of a gas-liquid transition at low densities. Upon an increase in 3He density, we predict a first-order phase transition between a dense liquid and a registered 7/12 phase, the 4/7 phase being found metastable in our calculations. At larger second-layer densities, a final transition is produced to an incommensurate triangular phase.

  2. a Solution for Dosimetry and Quality Assurance in Imrt and Hadrontherapy:. the Pixel Ionization Chamber

    NASA Astrophysics Data System (ADS)

    Amerio, S.; Coda, S.; Nastasi, U.; Belletti, S.; Ghedi, B.; Boriano, A.; Cirio, R.; Luparia, A.; Marchetto, F.; Peroni, C.; Sanz Freire, C. J.; Donetti, M.; Madon, E.; Trevisiol, E.; Urgesi, A.

    2002-11-01

    The new radiotherapy techniques require new detectors to monitor and measure the clinical field. The Intensity Modulated Radiation Therapy (IMRT) techniques like step and shoot, sliding window, dynamic wedge or scanning beam add the time variable to the treatment field. In this case the water phantom with a single ionization chamber moving inside the field needs very long measurement time. Linear arrays of ionization chambers or diodes measure the field only along a line. 2D detectors like radiographic or gafchromic film are not suitable to be used as on line detectors. We have developed, built and tested an ionization chamber segmented in pixels that measure the dose in a plane at several points. Every channel has a dedicated electronic chain that digitizes the collected charge and data from all the channels are sent to the computer that performs the data acquisition. One read out cycle is very fast allowing to measure in real time the fluency and the shape of the field. The chamber can be used in two different ways, as monitor chamber and as relative dosemeter. A description of the detector, the electronics, and test results with both photon and hadron beams will be reported.

  3. Stability of A-150 plastic ionization chamber response over a ~30 year period

    SciTech Connect

    Kroc, Thomas K.; Lennox, Arlene J.; /Fermilab

    2007-08-01

    At the NIU Institute for Neutron Therapy at Fermilab, the clinical tissue-equivalent ionization chamber response is measured every treatment day using a cesium source that was configured to match readings obtained at the National Bureau of Standards. Daily measurements are performed in air using the air-to-tissue dose conversion factors given in AAPM Report no. 7. The measured exposure calibration factors have been tabulated and graphed as a function of time from 1978 to present. For A-150 plastic ionization chambers, these factors exhibit a sinusoidal variation with a period of approximately one year and amplitude of {+-} 1%. This variation, attributable to the hygroscopic nature of A-150 plastic, is correlated with the relative humidity of the facility, and is greater than the humidity corrections for gas described in the literature. Our data suggest that chamber calibration should be performed at least weekly to accommodate these variations.

  4. High-resolution ion pulse ionization chamber with air filling for the 222Rn decays detection

    NASA Astrophysics Data System (ADS)

    Gavrilyuk, Yu. M.; Gangapshev, A. M.; Gezhaev, A. M.; Etezov, R. A.; Kazalov, V. V.; Kuzminov, V. V.; Panasenko, S. I.; Ratkevich, S. S.; Tekueva, D. A.; Yakimenko, S. P.

    2015-11-01

    The construction and characteristics of the cylindrical ion pulse ionization chamber (CIPIC) with a working volume of 3.2 L are described. The chamber is intended to register α-particles from the 222Rn and its daughter's decays in the filled air sample. The detector is less sensitive to electromagnetic pick-ups and mechanical noises. The digital pulse processing method is proposed to improve the energy resolution of the ion pulse ionization chamber. An energy resolution of 1.6% has been achieved for the 5.49 MeV α-line. The dependence of the energy resolution on high voltage and working media pressure has been investigated and the results are presented.

  5. Free-air ionization chamber, FAC-IR-300, designed for medium energy X-ray dosimetry

    NASA Astrophysics Data System (ADS)

    Mohammadi, S. M.; Tavakoli-Anbaran, H.; Zeinali, H. Z.

    2017-01-01

    The primary standard for X-ray photons is based on parallel-plate free-air ionization chamber (FAC). Therefore, the Atomic Energy Organization of Iran (AEOI) is tried to design and build the free-air ionization chamber, FAC-IR-300, for low and medium energy X-ray dosimetry. The main aim of the present work is to investigate specification of the FAC-IR-300 ionization chamber and design it. FAC-IR-300 dosimeter is composed of two parallel plates, a high voltage (HV) plate and a collector plate, along with a guard electrode that surrounds the collector plate. The guard plate and the collector were separated by an air gap. For obtaining uniformity in the electric field distribution, a group of guard strips was used around the ionization chamber. These characterizations involve determining the exact dimensions of the ionization chamber by using Monte Carlo simulation and introducing correction factors.

  6. Influence of ambient humidity on the current delivered by air-vented ionization chambers revisited

    NASA Astrophysics Data System (ADS)

    Poirier, Aurélie; Douysset, Guilhem

    2006-10-01

    The influence of ambient humidity on the current delivered by a vented ionization chamber has been re-investigated. A Nucletron 077.091 well-type chamber together with a 192Ir HDR brachytherapy source was enclosed in a climatic test chamber and the current was recorded for various humidity values. Great care has been taken for the design of the experimental setup in order to obtain reliable measurements of currents and humidity values inside the chamber active volume. A ±0.35% linear variation of the measured currents has been observed over a common range of humidities. This result is larger than the expected variation. No formal explanation of such a discrepancy has been found yet, however the present results could lead to a set of recommendations.

  7. SU-E-T-623: Polarity Effects for Small Volume Ionization Chambers in Cobalt-60 Beams

    SciTech Connect

    Xu, Y; Bhatnagar, J; Huq, M Saiful

    2015-06-15

    Purpose: To investigate the polarity effects for small volume ionization chambers in {sup 60}Co gamma-ray beams using the Leksell Gamma Knife Perfexion. Methods: Measurements were made for 7 small volume ionization chambers (a PTW 31016, an Exradin A14, 2 Capintec PR0-5P, and 3 Exradin A16) using a PTW UNIDOSwebline Universal Dosemeter and an ELEKTA solid water phantom with proper inserts. For each ion chamber, the temperature/pressure corrected electric charge readings were obtained for 16 voltage values (±50V, ±100V, ±200V, ±300V, ±400V, ±500V, ±600V, ±700V). For each voltage, a five-minute leakage charge reading and a series of 2-minute readings were continuously taken during irradiation until 5 stable signals (less than 0.05% variation) were obtained. The average of the 5 reading was then used for the calculation of the polarity corrections at the voltage and for generating the saturation curves. Results: The polarity effects are more pronounced at high or low voltages than at the medium voltages for all chambers studied. The voltage dependence of the 3 Exradin A16 chambers is similar in shape. The polarity corrections for the Exradin A16 chambers changes rapidly from about 1 at 500V to about 0.98 at 700V. The polarity corrections for the 7 ion chambers at 300V are in the range from 0.9925 (for the PTW31016) to 1.0035 (for an Exradin A16). Conclusion: The polarity corrections for certain micro-chambers are large even at normal operating voltage.

  8. Towards reference dosimetry for the MR-linac: magnetic field correction of the ionization chamber reading

    NASA Astrophysics Data System (ADS)

    Smit, K.; van Asselen, B.; Kok, J. G. M.; Aalbers, A. H. L.; Lagendijk, J. J. W.; Raaymakers, B. W.

    2013-09-01

    In the UMC Utrecht a prototype MR-linac has been installed. The system consists of a 6 MV Elekta (Crawley, UK) linear accelerator and a 1.5 T Philips (Best, The Netherlands) Achieva MRI system. This paper investigates the feasibility to correct the ionization chamber reading for the magnetic field within the dosimetry calibration method described by Almond et al (1999 Med. Phys. 26 1847-70). Firstly, the feasibility of using an ionization chamber in an MR-linac was assessed by investigating possible influences of the magnetic field on NE2571 Farmer-type ionization chamber characteristics: linearity, repeatability, orientation in the magnetic field; and AAPM TG51 correction factor for voltage polarity and ion recombination. We found that these AAPM correction factors for the NE2571 chamber were not influenced by the magnetic field. Secondly, the influence of the permanent 1.5 T magnetic field on the NE2571 chamber reading was quantified. The reading is influenced by the magnetic field; therefore, a correction factor has been added. For the standardized setup used in this paper, the NE2571 chamber reading increases by 4.9% (± 0.2%) due to the transverse 1.5 T magnetic field. Dosimetry measurements in an MR-linac are feasible, if a setup-specific magnetic field correction factor (P1.5 T) for the charge reading is introduced. For the setup investigated in this paper, the P1.5 T has a value of 0.953.

  9. Particle and energy dependence of the statistical fluctuations of an ionization chamber current

    NASA Astrophysics Data System (ADS)

    Purghel, Lidia; Vaˆlcov, Nicolae

    For the purpose of getting more detailed information concerning the processes leading to statistical fluctuations of an ionization chamber current, measurements with various radioactive sources have been done. By using the experimental arrangement described elsewhere [A. Necula et al. Nucl. Instr. and Meth. A 332 (1993) 501] the mean value and the standard deviation of the ionization current for 3H (water vapours), 60Co (sealed source), 85Kr (gas), 204Tl (8 mm diameter disk) and 239Pu (10 mm diameter disk), beta, gamma and alpha sources have been measured. A statistical model explaining the experimental data is proposed.

  10. PTRAC File Utilization for Calculation of Free-Air Ionization Chamber Correction Factors by MCNPX

    NASA Astrophysics Data System (ADS)

    Šolc, Jaroslav; Sochor, Vladimír

    2014-06-01

    A free-air ionization chamber is used as a standard of photon air-kerma. Several correction factors are applied to the air-kerma value. Correction factors for electron loss (kloss) and for additional ionization current caused by photon scatter (ksc), photon fluorescence (kfl), photon transmission through diaphragm edge (kdtr), and photon scatter from the surface of the diaphragm aperture (kdsc) were determined by the MCNPX code utilizing information stored in Particle Track (PTRAC) output files. Individual steps of the procedure are described and the calculated values of the correction factors are presented. The values are in agreement with the correction factors published in a literature for similar free-air chambers.

  11. Neutron and gamma detector using an ionization chamber with an integrated body and moderator

    DOEpatents

    Ianakiev, Kiril D.; Swinhoe, Martyn T.; Lestone, John Paul

    2006-07-18

    A detector for detecting neutrons and gamma radiation includes a cathode that defines an interior surface and an interior volume. A conductive neutron-capturing layer is disposed on the interior surface of the cathode and a plastic housing surrounds the cathode. A plastic lid is attached to the housing and encloses the interior volume of the cathode forming an ionization chamber, into the center of which an anode extends from the plastic lid. A working gas is disposed within the ionization chamber and a high biasing voltage is connected to the cathode. Processing electronics are coupled to the anode and process current pulses which are converted into Gaussian pulses, which are either counted as neutrons or integrated as gammas, in response to whether pulse amplitude crosses a neutron threshold. The detector according to the invention may be readily fabricated into single or multilayer detector arrays.

  12. Hard disk drive based microsecond x-ray chopper for characterization of ionization chambers and photodiodes

    SciTech Connect

    Müller, O. Lützenkirchen-Hecht, D.; Frahm, R.

    2015-03-15

    A fast X-ray chopper capable of producing ms long X-ray pulses with a typical rise time of few μs was realized. It is ideally suited to investigate the temporal response of X-ray detectors with response times of the order of μs to ms, in particular, any kind of ionization chambers and large area photo diodes. The drive mechanism consists of a brushless DC motor and driver electronics from a common hard disk drive, keeping the cost at an absolute minimum. Due to its simple construction and small dimensions, this chopper operates at home lab based X-ray tubes and synchrotron radiation sources as well. The dynamics of the most important detectors used in time resolved X-ray absorption spectroscopy, namely, ionization chambers and Passivated Implanted Planar Silicon photodiodes, were investigated in detail. The results emphasize the applicability of this X-ray chopper.

  13. Hard disk drive based microsecond X-ray chopper for characterization of ionization chambers and photodiodes.

    PubMed

    Müller, O; Lützenkirchen-Hecht, D; Frahm, R

    2015-03-01

    A fast X-ray chopper capable of producing ms long X-ray pulses with a typical rise time of few μs was realized. It is ideally suited to investigate the temporal response of X-ray detectors with response times of the order of μs to ms, in particular, any kind of ionization chambers and large area photo diodes. The drive mechanism consists of a brushless DC motor and driver electronics from a common hard disk drive, keeping the cost at an absolute minimum. Due to its simple construction and small dimensions, this chopper operates at home lab based X-ray tubes and synchrotron radiation sources as well. The dynamics of the most important detectors used in time resolved X-ray absorption spectroscopy, namely, ionization chambers and Passivated Implanted Planar Silicon photodiodes, were investigated in detail. The results emphasize the applicability of this X-ray chopper.

  14. Hard disk drive based microsecond x-ray chopper for characterization of ionization chambers and photodiodes

    NASA Astrophysics Data System (ADS)

    Müller, O.; Lützenkirchen-Hecht, D.; Frahm, R.

    2015-03-01

    A fast X-ray chopper capable of producing ms long X-ray pulses with a typical rise time of few μs was realized. It is ideally suited to investigate the temporal response of X-ray detectors with response times of the order of μs to ms, in particular, any kind of ionization chambers and large area photo diodes. The drive mechanism consists of a brushless DC motor and driver electronics from a common hard disk drive, keeping the cost at an absolute minimum. Due to its simple construction and small dimensions, this chopper operates at home lab based X-ray tubes and synchrotron radiation sources as well. The dynamics of the most important detectors used in time resolved X-ray absorption spectroscopy, namely, ionization chambers and Passivated Implanted Planar Silicon photodiodes, were investigated in detail. The results emphasize the applicability of this X-ray chopper.

  15. Some specific features of ionization chamber calibrations in linac x-ray beams at the LNE-LNHB.

    PubMed

    Delaunay, F; Ostrowsky, A

    2007-05-07

    The purpose of this note is to give some details about the modus operandi employed today to calibrate ionization chambers in radiotherapy linac photon beams at the Laboratoire National Henri Becquerel (LNE-LNHB). Some specific features are described: first the equipment (including the external monitoring ionization chambers), second the calculations of the profile or radial non-uniformity correction factors (up to 0.5% effect for commonly used ionization chambers) and finally the calculations to get the calibration coefficients for customer beam qualities.

  16. Dosimetric characteristics of the novel 2D ionization chamber array OCTAVIUS Detector 1500

    SciTech Connect

    Stelljes, T. S. Looe, H. K.; Chofor, N.; Poppe, B.; Harmeyer, A.; Reuter, J.; Harder, D.

    2015-04-15

    Purpose: The dosimetric properties of the OCTAVIUS Detector 1500 (OD1500) ionization chamber array (PTW-Freiburg, Freiburg, Germany) have been investigated. A comparative study was carried out with the OCTAVIUS Detector 729 and OCTAVIUS Detector 1000 SRS arrays. Methods: The OD1500 array is an air vented ionization chamber array with 1405 detectors in a 27 × 27 cm{sup 2} measurement area arranged in a checkerboard pattern with a chamber-to-chamber distance of 10 mm in each row. A sampling step width of 5 mm can be achieved by merging two measurements shifted by 5 mm, thus fulfilling the Nyquist theorem for intensity modulated dose distributions. The stability, linearity, and dose per pulse dependence were investigated using a Semiflex 31013 chamber (PTW-Freiburg, Freiburg, Germany) as a reference detector. The effective depth of measurement was determined by measuring TPR curves with the array and a Roos chamber type 31004 (PTW-Freiburg, Freiburg, Germany). Comparative output factor measurements were performed with the array, the Semiflex 31010 ionization chamber and the Diode 60012 (both PTW-Freiburg, Freiburg, Germany). The energy dependence of the OD1500 was measured by comparing the array’s readings to those of a Semiflex 31010 ionization chamber for varying mean photon energies at the depth of measurement, applying to the Semiflex chamber readings the correction factor k{sub NR} for nonreference conditions. The Gaussian lateral dose response function of a single array detector was determined by searching the convolution kernel suitable to convert the slit beam profiles measured with a Diode 60012 into those measured with the array’s central chamber. An intensity modulated dose distribution measured with the array was verified by comparing a OD1500 measurement to TPS calculations and film measurements. Results: The stability and interchamber sensitivity variation of the OD1500 array were within ±0.2% and ±0.58%, respectively. Dose linearity was within 1

  17. SU-E-T-525: Ionization Chamber Perturbation in Flattening Filter Free Beams

    SciTech Connect

    Czarnecki, D; Voigts-Rhetz, P von; Zink, K

    2015-06-15

    Purpose: Changing the characteristic of a photon beam by mechanically removing the flattening filter may impact the dose response of ionization chambers. Thus, perturbation factors of cylindrical ionization chambers in conventional and flattening filter free photon beams were calculated by Monte Carlo simulations. Methods: The EGSnrc/BEAMnrc code system was used for all Monte Carlo calculations. BEAMnrc models of nine different linear accelerators with and without flattening filter were used to create realistic photon sources. Monte Carlo based calculations to determine the fluence perturbations due to the presens of the chambers components, the different material of the sensitive volume (air instead of water) as well as the volume effect were performed by the user code egs-chamber. Results: Stem, central electrode, wall, density and volume perturbation factors for linear accelerators with and without flattening filter were calculated as a function of the beam quality specifier TPR{sub 20/10}. A bias between the perturbation factors as a function of TPR{sub 20/10} for flattening filter free beams and conventional linear accelerators could not be observed for the perturbations caused by the components of the ionization chamber and the sensitive volume. Conclusion: The results indicate that the well-known small bias between the beam quality correction factor as a function of TPR20/10 for the flattening filter free and conventional linear accelerators is not caused by the geometry of the detector but rather by the material of the sensitive volume. This suggest that the bias for flattening filter free photon fields is only caused by the different material of the sensitive volume (air instead of water)

  18. Differences between signal currents for both polarities of applied voltages on cavity ionization chambers

    NASA Astrophysics Data System (ADS)

    Takata, N.

    2001-06-01

    A difference between the surface potential of the charge collecting electrode and that of the guard electrode of an ionization chamber changes the charge collecting volume depending on the applied voltage. If the difference is large, the saturation curve of the signal current shows a maximum at a low applied voltage. Even when there is no electrical or mechanical defect, the signal current from a parallel plate ionization chamber irradiated with 60Co γ-rays increases or decreases with the applied voltage beyond the recombination region depending on the polarity of the applied voltage. The variation in the signal current is explained as a result of the change in the stopping power of air due to the acceleration or deceleration of secondary electrons. These electrons are emitted from the polarizing electrode towards the collector as a result of Compton scattering. In a range of low applied voltages, the signal current from a cylindrical ionization chamber is expected to be smaller for a negative applied voltage than for a positive applied voltage. This is because epithermal electrons are expected to have a higher probability of being lost by back diffusion than positive ions which are originally produced in a thermal equilibrium condition. An experimental result, however, showed no difference in the polarities of the applied voltage. The result may be explained as a consequence of the fact that epithemal electrons do not drift for long distances and maintain their energies.

  19. A position-sensitive twin ionization chamber for fission fragment and prompt neutron correlation experiments

    NASA Astrophysics Data System (ADS)

    Göök, A.; Geerts, W.; Hambsch, F.-J.; Oberstedt, S.; Vidali, M.; Zeynalov, Sh.

    2016-09-01

    A twin position-sensitive Frisch grid ionization chamber, intended as a fission fragment detector in experiments to study prompt fission neutron correlations with fission fragment properties, is presented. Fission fragment mass and energies are determined by means of the double kinetic energy technique, based on conservation of mass and linear momentum. The position sensitivity is achieved by replacing each anode plate in the standard twin ionization chamber by a wire plane and a strip anode, both readout by means of resistive charge division. This provides information about the fission axis orientation, which is necessary to reconstruct the neutron emission process in the fully accelerated fragment rest-frame. The energy resolution compared to the standard twin ionization chamber is found not to be affected by the modification. The angular resolution of the detector relative to an arbitrarily oriented axis is better than 7° FWHM. Results on prompt fission neutron angular distributions in 235U(n,f) obtained with the detector in combination with an array of neutron scintillation detectors is presented as a proof of principle.

  20. An evaluation of ionization chambers for the relative dosimetry of kilovoltage x-ray beams

    SciTech Connect

    Hill, Robin; Mo Zhao; Haque, Mamoon; Baldock, Clive

    2009-09-15

    In this work, the authors have evaluated ten different ionization chambers for the relative dosimetry of kilovoltage x-ray beams in the energy range of 50-280 kVp. Percentage depth doses in water and relative detector response (in Solid Water and in air) were measured for each of the x-ray beams studied using a number of chambers. Measured depth dose data were compared with Monte Carlo calculated depth doses using the EGSnrc Monte Carlo package and the BEAMnrc user code. The accuracy of the phase space files generated by BEAMnrc was verified by calculating the half-value layer and comparing with the measured half-value layer of each x-ray beam. The results indicate that the Advanced Markus, Markus, NACP, and Roos parallel plate ionization chambers were suitable for the measurement of depth dose data in this beam quality range with an uncertainty of less than 3%, including in the regions close to the water surface. While the relative detector response of the Farmer and scanning thimble chambers exhibited a better energy response, they were not suitable for depth dose measurements in the first 5 mm below the water surface with differences of up to 12% in the surface dose measurement for the 50 kVp x-ray beam. These differences were due to dose artifacts generated by the chamber size and the dose gradient. However, at depths greater than 5 mm, the Farmer and thimble scanning chambers gave uncertainties of less than 3% for the depth dose measurements for all beam energies. The PTW PinPoint 31006 chamber was found to give varying dose differences of up to 8% depending on the x-ray beam energy; this was attributed to the steel central electrode. The authors recommend that one of the parallel plate ionization chambers investigated be used to determine depth dose data for kilovoltage x-ray beams in the energy range studied and give correct dose information close to the surface and at depth in the water phantom.

  1. A numerical model of initial recombination for high-LET irradiation: Application to liquid-filled ionization chambers

    NASA Astrophysics Data System (ADS)

    Aguiar, P.; Pardo-Montero, J.

    2016-02-01

    In this paper we present a numerical model of initial recombination in media irradiated with high linear energy transfer (LET) ions, which relies on an amorphous track model of ionization of high LET particles, and diffusion, drift and recombination of ionized charge carriers. The model has fundamental applications for the study of recombination in non-polar liquids, as well as practical ones, like in modelling hadrontherapy dosimetry with ionization chambers. We have used it to study the response of liquid-filled ionization chambers to hadrontherapy beams: dependence of initial recombination on ion species, energy and applied external electric field.

  2. Application of the two-dose-rate method for general recombination correction for liquid ionization chambers in continuous beams

    NASA Astrophysics Data System (ADS)

    Andersson, Jonas; Tölli, Heikki

    2011-01-01

    A method to correct for the general recombination losses for liquid ionization chambers in continuous beams has been developed. The proposed method has been derived from Greening's theory for continuous beams and is based on measuring the signal from a liquid ionization chamber and an air filled monitor ionization chamber at two different dose rates. The method has been tested with two plane parallel liquid ionization chambers in a continuous radiation x-ray beam with a tube voltage of 120 kV and with dose rates between 2 and 13 Gy min-1. The liquids used as sensitive media in the chambers were isooctane (C8H18) and tetramethylsilane (Si(CH3)4). The general recombination effect was studied using chamber polarizing voltages of 100, 300, 500, 700 and 900 V for both liquids. The relative standard deviation of the results for the collection efficiency with respect to general recombination was found to be a maximum of 0.7% for isooctane and 2.4% for tetramethylsilane. The results are in excellent agreement with Greening's theory for collection efficiencies over 90%. The measured and corrected signals from the liquid ionization chambers used in this work are in very good agreement with the air filled monitor chamber with respect to signal to dose linearity.

  3. Application of the two-dose-rate method for general recombination correction for liquid ionization chambers in continuous beams.

    PubMed

    Andersson, Jonas; Tölli, Heikki

    2011-01-21

    A method to correct for the general recombination losses for liquid ionization chambers in continuous beams has been developed. The proposed method has been derived from Greening's theory for continuous beams and is based on measuring the signal from a liquid ionization chamber and an air filled monitor ionization chamber at two different dose rates. The method has been tested with two plane parallel liquid ionization chambers in a continuous radiation x-ray beam with a tube voltage of 120 kV and with dose rates between 2 and 13 Gy min(-1). The liquids used as sensitive media in the chambers were isooctane (C(8)H(18)) and tetramethylsilane (Si(CH(3))(4)). The general recombination effect was studied using chamber polarizing voltages of 100, 300, 500, 700 and 900 V for both liquids. The relative standard deviation of the results for the collection efficiency with respect to general recombination was found to be a maximum of 0.7% for isooctane and 2.4% for tetramethylsilane. The results are in excellent agreement with Greening's theory for collection efficiencies over 90%. The measured and corrected signals from the liquid ionization chambers used in this work are in very good agreement with the air filled monitor chamber with respect to signal to dose linearity.

  4. Calibration of the KRISS reference ionization chamber for certification of ²²²Rn gaseous sources.

    PubMed

    Lee, J M; Lee, K B; Lee, S H; Oh, P J; Park, T S; Kim, B C; Lee, M S

    2013-11-01

    A primary measurement system for gaseous (222)Rn based on the defined solid angle counting method has recently been constructed at KRISS and the reference ionization chamber used to measure the activities of gamma-emitting single radionuclides was adopted as a secondary standard for gaseous (222)Rn. A 20 mL flame-sealed glass ampoule source from the primary measurement system was used to calibrate the ionization chamber for (222)Rn. The (222)Rn efficiency of the ionization chamber was compared with that calculated by using a photon energy-dependent efficiency curve and that measured by using a standard (226)Ra solution. From the comparisons we draw the conclusion that the reference ionization chamber for gamma-emitting radionuclides can be a suitable secondary measurement system for gaseous (222)Rn sources.

  5. The calibration and use of plane-parallel ionization chambers for dosimetry of electron beams.

    PubMed

    Almond, P R; Xu, Z; Li, H; Park, H C

    1995-08-01

    The AAPM TG 39 protocol has proposed three different methods of calibrating plane-parallel ionization chambers, i.e., in-phantom irradiation with a high-energy electron beam and in-phantom and in-air 60Co irradiation. To verify the consistency of the three methods, we have measured Ngaspp values using each of these techniques for the five most commonly used plane-parallel chambers considered by the protocol. Our results demonstrate that the measured Ngaspp values for the three different methods for any of the chambers agree to within +/- 0.6%. Once Ngaspp was measured, the determination of absorbed dose for electron beams with different energies for an AECL Therac 20 and Philips SL25 was carried out according to the AAPM TG 39 protocol. The results show that the determination of the absorbed dose outputs for any of the five chambers agree to within +/- 0.7% for electron-beam energies of 4-20 MeV if all five chambers had Ngaspp values determined by the electron-beam method. The uncertainties are well within the expected error for these approaches.

  6. Apparatus for deformation tests of solids in liquid 3He

    NASA Astrophysics Data System (ADS)

    Hashimoto, T.; Katakura, S.; Edagawa, K.; Takeuchi, S.; Suzuki, T.

    2000-07-01

    An apparatus for deformation of solids in liquid 3He is constructed. Either tensile deformation or compression of a specimen can be performed by exchanging the assemblies in the 3He pot which has a capacity of about 30 cm3. The pulling rod for transmitting load from the tensile testing machine to the specimen runs inside the outlet tube of 3He, being isolated from 4He bath and almost free from mechanical friction. To measure the change in flow stress with the supernormal transition of superconducting metals, a superconducting magnet is mounted outside of the vacuum chamber which separates the 3He pot and the 4He bath. Under an applied load for plastic deformation the system is stably operative down to 0.6 K, while the lowest temperature achieved is 0.5 K. Some results on Ta and NaCl are presented.

  7. Development of a thermodynamic model for a cold cycle 3He-4He dilution refrigerator

    NASA Astrophysics Data System (ADS)

    Mueller, B. W.; Miller, F. K.

    2016-10-01

    A thermodynamic model of a 3He-4He cold cycle dilution refrigerator with no actively-driven mechanical components is developed and investigated. The refrigerator employs a reversible superfluid magnetic pump, passive check valves, a phase separation chamber, and a series of recuperative heat exchangers to continuously circulate 3He-4He and maintain a 3He concentration gradient across the mixing chamber. The model predicts cooling power and mixing chamber temperature for a range of design and operating parameters, allowing an evaluation of feasibility for potential 3He-4He cold cycle dilution refrigerator prototype designs. Model simulations for a prototype refrigerator design are presented.

  8. The response of prototype plane-parallel ionization chambers in small megavoltage x-ray fields.

    PubMed

    McNiven, Andrea L; Mulligan, Matt; Kron, Tomas; Battista, Jerry J

    2006-11-01

    Accurate small-field dosimetry has become important with the use of multiple small fields in modern radiotherapy treatments such as IMRT and stereotactic radiosurgery. In this study, we investigate the response of a set of prototype plane-parallel ionization chambers, based upon the Exradin T11 chamber, with active volume diameters of 2, 4, 10, and 20 mm, exposed to 6 MV stereotactic radiotherapy x-ray fields. Our goal was to assess their usefulness for accurate small x-ray field dose measurements. The relative ionization response was measured in circular fields (0.5 to 4 cm diameter) as compared to a 10 x 10 cm2 reference field. A large discrepancy (approximately 40%) was found between the relative response in the smallest plane-parallel chamber and other small volume dosimeters (radiochromic film, micro-metal-oxide-semiconductor field-effect transistor and diode) used for comparison. Monte Carlo BEAMnrc simulations were used to simulate the experimental setup in order to investigate the cause of the under-response and to calculate appropriate correction factors that could be applied to experimental measurements. It was found that in small fields, the air cavity of these custom-made research chambers perturbed the secondary electron fluence profile significantly, resulting in decreased fluence within the active volume, which in turn produces a chamber under-response. It is demonstrated that a large correction to the p(fl) correction factor would be required to improve dosimetric accuracy in small fields, and that these factors could be derived using Monte Carlo simulations.

  9. Measurement of photon flux with a miniature gas ionization chamber in a Material Testing Reactor

    NASA Astrophysics Data System (ADS)

    Fourmentel, D.; Filliatre, P.; Villard, J. F.; Lyoussi, A.; Reynard-Carette, C.; Carcreff, H.

    2013-10-01

    Nuclear heating measurements in Material Testing Reactors (MTR) are crucial for the design of the experimental devices and the prediction of the temperature of the hosted samples. Nuclear heating in MTR materials (except fuel) is mainly due to the energy deposition by the photon flux. Therefore, the photon flux is a key input parameter for the computer codes which simulate nuclear heating and temperature reached by samples/devices under irradiation. In the Jules Horowitz MTR under construction at the CEA Cadarache, the maximal expected nuclear heating levels will be about 15 to 18 W g-1 and it will be necessary to assess this parameter with the best accuracy. An experiment was performed at the OSIRIS reactor to combine neutron flux, photon flux and nuclear heating measurements to improve the knowledge of the nuclear heating in MTR. There are few appropriate sensors for selective measurement of the photon flux in MTR even if studies and developments are ongoing. An experiment, called CARMEN-1, was conducted at the OSIRIS MTR and we used in particular a gas ionization chamber based on miniature fission chamber design to measure the photon flux. In this paper, we detail Monte-Carlo simulations to analyze the photon fluxes with ionization chamber measurements and we compare the photon flux calculations to the nuclear heating measurements. These results show a good accordance between photon flux measurements and nuclear heating measurement and allow improving the knowledge of these parameters.

  10. Use of relativistic rise in ionization chambers for measurement of high energy heavy nuclei

    NASA Technical Reports Server (NTRS)

    Barthelmy, S. D.; Israel, M. H.; Klarmann, J.; Vogel, J. S.

    1983-01-01

    A balloon-borne instrument has been constructed to measure the energy spectra of cosmic-ray heavy nuclei in the range of about 0.3 to about 100 GeV/amu. It makes use of the relativistic rise portion of the Bethe-Bloch curve in ionization chambers for energy determination in the 10- to 100-GeV/amu interval. The instrument consists of six layers of dual-gap ionization chambers for energy determination above 10 GeV/amu. Charge is determined with a NE114 scintillator and a Pilot 425 plastic Cerenkov counter. A CO2 gas Cerenkov detector (1 atm; threshold of 30 GeV/amu) calibrates the ion chambers in the relativistic rise region. The main emphasis of the instrument is the determination of the change of the ratio of Iron (26) to the Iron secondaries (21-25) in the energy range of 10 to 100 GeV/amu. Preliminary data from a balloon flight in the fall of 1982 from Palestine, TX is presented.

  11. Ambiguities in the grid-inefficiency correction for Frisch-Grid Ionization Chambers

    NASA Astrophysics Data System (ADS)

    Al-Adili, A.; Hambsch, F.-J.; Bencardino, R.; Oberstedt, S.; Pomp, S.

    2012-05-01

    Ionization chambers with Frisch grids have been very successfully applied to neutron-induced fission-fragment studies during the past 20 years. They are radiation resistant and can be easily adapted to the experimental conditions. The use of Frisch grids has the advantage to remove the angular dependency from the charge induced on the anode plate. However, due to the Grid Inefficiency (GI) in shielding the charges, the anode signal remains slightly angular dependent. The correction for the GI is, however, essential to determine the correct energy of the ionizing particles. GI corrections can amount to a few percent of the anode signal. Presently, two contradicting correction methods are considered in literature. The first method adding the angular-dependent part of the signal to the signal pulse height; the second method subtracting the former from the latter. Both additive and subtractive approaches were investigated in an experiment where a Twin Frisch-Grid Ionization Chamber (TFGIC) was employed to detect the spontaneous fission fragments (FF) emitted by a 252Cf source. Two parallel-wire grids with different wire spacing (1 and 2 mm, respectively), were used individually, in the same chamber side. All the other experimental conditions were unchanged. The 2 mm grid featured more than double the GI of the 1 mm grid. The induced charge on the anode in both measurements was compared, before and after GI correction. Before GI correction, the 2 mm grid resulted in a lower pulse-height distribution than the 1 mm grid. After applying both GI corrections to both measurements only the additive approach led to consistent grid independent pulse-height distributions. The application of the subtractive correction on the contrary led to inconsistent, grid-dependent results. It is also shown that the impact of either of the correction methods is small on the FF mass distributions of 235U(nth, f).

  12. Monte Carlo calculations of correction factors for plane-parallel ionization chambers in clinical electron dosimetry

    SciTech Connect

    Araki, Fujio

    2008-09-15

    Recent standard dosimetry protocols recommend that plane-parallel ionization chambers be used in the measurements of depth-dose distributions or the calibration of low-energy electron beams with beam quality R{sub 50}<4 g/cm{sup 2}. In electron dosimetry protocols with the plane-parallel chambers, the wall correction factor, P{sub wall}, in water is assumed to be unity and the replacement correction factor, P{sub repl}, is taken to be unity for well-guarded plane-parallel chambers, at all measurement depths. This study calculated P{sub wall} and P{sub repl} for NACP-02, Markus, and Roos plane-parallel chambers in clinical electron dosimetry using the EGSnrc Monte Carlo code system. The P{sub wall} values for the plane-parallel chambers increased rapidly as a function of depth in water, especially at lower energy. The value around R{sub 50} for NACP-02 was about 10% greater than unity at 4 MeV. The effect was smaller for higher electron energies. Similarly, P{sub repl} values with depth increased drastically at the region with the steep dose gradient for lower energy. For Markus P{sub repl} departed more than 10% from unity close to R{sub 50} due to the narrow guard ring width. P{sub repl} for NACP-02 and Roos was close to unity in the plateau region of depth-dose curves that includes a reference depth, d{sub ref}. It was also found that the ratio of the dose to water and the dose to the sensitive volume in the air cavity for the plane-parallel chambers, D{sub w}/[D{sub air}]{sub pp}, at d{sub ref} differs significantly from that assumed by electron dosimetry protocols.

  13. Argon/propane ionization-chamber dosimetry for mixed x-ray/neutron fields.

    PubMed

    Schulz, R J

    1978-01-01

    The photoneutrons produced by high-energy x-ray machines can diffuse through the mazes usually employed at the treatment-room entrance and readily penetrate the lead-lined doors used for x-ray shielding. The measurement of these neutrons in the presence of x-rays and the determination of dose equivalent poses a problem for which there is currently no standard method of solution. In order to separate x-ray dose from neutron dose, the author employed an ionization chamber alternately filled with argon or propane. The response characteristics of this chamber to x-ray and neutrons are described. Quality factors were determined from a calculated neutron spectrum. As a result of these measurements, a 10-in. polyethylene door was added to the entranceway of a 25-MV linear accelerator.

  14. Feasibility of calibrating elongated brachytherapy sources using a well-type ionization chamber

    SciTech Connect

    Meigooni, Ali S.; Awan, Shahid B.; Dou, Kai

    2006-11-15

    Recently, elongated brachytherapy sources (active length >1 cm) have become commercially available for interstitial prostate implants. These sources were introduced to improve the quality of brachytherapy procedures by eliminating the migration and seed bunching associated with loose seed-type implants. However, the inability to calibrate elongated brachytherapy sources with the Wide-Angle Free-Air Chamber (WAFAC) used by the National Institute of Standards and Technology (NIST) hinders the experimental determination of dosimetric parameters of these source types. In order to resolve this shortcoming, an interim solution has been introduced for calibration of elongated brachytherapy sources using a commercially available well-type ionization chamber. The feasibility of this procedure was examined by calibrating RadioCoil{sup Tm} {sup 103}Pd sources with active lengths ranging from 1 to 7 cm.

  15. An ionization chamber and a Si-detector for lead-210 chronology

    NASA Astrophysics Data System (ADS)

    Farid, M.; El-Daoushy, A. F.; El-Daoushy, M. F. A. F.

    1981-09-01

    Radon emanation and isotopic dilution techniques were used for the determination of 226Ra and "total" 210Pb in sediment samples. The "unsupported" 210Pb were then used to construct lake-sediment chronologies. Polonium was extracted at 550-600°C, transferred to chloride, then plated by self-deposition on silver disks. Memory effects due to adsorption of polonium on glass were carefully studied. Si-detectors were used for α-activity measurements. Background studies indicated instabilities in a Si-detector when left without bias for longer periods. The radium was extracted with the help of a barium carrier, which not only made the extraction quantitative but also eliminated the adsorption of radium on the glasses used. The 222Rn was measured in an ionization chamber. The gas counter with its modified filling system allowed both low level measurements of sediment samples and counter calibration with comparably active 226Ra standards. The increasing background of the ionization chamber was explained by the adsorption of 222Rn on the surfaces of the counter. The background was reduced by the removal of the adsorbed atoms. Normalization for discrimination shifts, due to electronegative impurities, is required in case the counting gas is impure.

  16. Strip Ionization Chamber as Beam Monitor in the Proton Therapy Eye Treatment

    NASA Astrophysics Data System (ADS)

    Marchetto, F.; Cirio, R.; Garella, M. A.; Giordanengo, S.; Boriano, A.; Givehchi, N.; La Rosa, A.; Peroni, C.; Donetti, M.; Bourhaleb, F.; Pitta', G.; Cirrone, G. A. P.; Cuttone, G.; Raffaele, L.; Sabini, M. G.; Valastro, L.

    2006-04-01

    Since spring 2002, ocular pathologies have been treated in Catania at the Centro di AdroTerapia e Applicazioni Nucleari Avanzate (CATANA) within a collaboration between INFN Laboratori Nazionali del Sud (LNS), Physics Department, Ophthalmology Institute, Radiology Institute of the Catania University and CSFNSM Catania. A beam line from a 62 MeV Superconducting Cyclotron is used to treat shallow tumors. The beam is conformed to the tumor shape with a passive delivery system. A detector system has been developed in collaboration with INFN-Torino to be used as real time beam monitor. The detector, placed upstream of the patient collimator, consists of two parallel plate ionization chambers with the anode segmented in strips. Each anode is made of 0.5 mm-wide 256 strips corresponding to (12.8 × 12.8) cm2 sensitive area. With the two strip ionization chambers one can measure the relevant beam parameters during treatment to probe both asymmetry and flatness. In the test carried out at CATANA the detector has been used under different and extreme beam conditions. Preliminary results are given for profiles and skewness, together with a comparison with reference detectors.

  17. High-rate axial-field ionization chamber for particle identification of Radioactive beams

    NASA Astrophysics Data System (ADS)

    Desouza, Romualdo; Vadas, Justin; Singh, Varinderjit; Visser, G.; Alexander, A.; Hudan, S.; Huston, J.; Wiggins, B.; Chbihi, A.; Famiano, M.; Bischak, M.

    2017-01-01

    The design, construction and performance characteristics of a simple axial-field ionization chamber suitable for identifying ions in a radioactive beam are presented. The detector is optimized for use with low-energy radioactive beams (<) 5 MeV/A. A fast charge sensitive amplifier (CSA) integrated into the detector design is also described. Coupling this fast CSA to the axial field ionization chamber produces an output pulse with a rise-time of 60 to 70 ns and a fall time of 100 ns, making the detector capable of sustaining a relatively high rate while providing a time resolution of 6 to 8 ns. Tests with an α source establish the detector energy resolution as 8 % for an energy deposit of 3.5 MeV. Beam tests indicate that the detector is an effective tool for the characterization of low-energy radioactive beams at beam intensities up to 3 x 105 ions/s. Supported by the U.S. DOE under Award # DE-FG02-88ER-40404 and the NSF under Grant No. 1342962.

  18. High-rate axial-field ionization chamber for particle identification of radioactive beams

    NASA Astrophysics Data System (ADS)

    Vadas, J.; Singh, Varinderjit; Visser, G.; Alexander, A.; Hudan, S.; Huston, J.; Wiggins, B. B.; Chbihi, A.; Famiano, M.; Bischak, M. M.; deSouza, R. T.

    2016-11-01

    The design, construction and performance characteristics of a simple axial-field ionization chamber suitable for identifying ions in a radioactive beam are presented. Optimized for use with low-energy radioactive beams (< 5 MeV / A) the detector presents only three 0.5 μm/cm2 foils to the beam in addition to the detector gas. A fast charge sensitive amplifier (CSA) integrated into the detector design is also described. Coupling this fast CSA to the axial field ionization chamber produces an output pulse with a risetime of 60-70 ns and a fall time of 100 ns, making the detector capable of sustaining a relatively high rate and providing a time resolution of 6-8 ns. Tests with an α source establish the detector energy resolution as ∼ 8 % for an energy deposit of ∼3.5 MeV. The energy resolution with beams of 2.5 and 4.0 MeV/A 39K ions and the dependence of the energy resolution on beam intensity is measured. At an instantaneous rate of 3×105 ions/s the energy resolution has degraded to 14% with a pileup of 12%. The good energy resolution of this detector at rates up to 3×105 ions/s makes it an effective tool in the characterization of low-energy radioactive beams.

  19. Technical Note: Experimental determination of the effective point of measurement of two cylindrical ionization chambers in a clinical proton beam

    SciTech Connect

    Sugama, Yuya; Nishio, Teiji; Onishi, Hiroshi

    2015-07-15

    Purpose: IAEA TRS-398 notes that cylindrical ionization chambers are preferred for reference proton dosimetry. If a cylindrical ionization chamber is used in a phantom to measure the dose as a function of depth, the effective point of measurement (EPOM) must be taken into account. IAEA TRS-398 recommends a displacement of 0.75 times the inner cavity radius (0.75R) for heavy ion beams. Theoretical models by Palmans and by Bhullar and Watchman confirmed this value. However, the experimental results vary from author to author. The purpose of this study is to accurately measure the displacement and explain the past experimental discrepancies. Methods: In this work, we measured the EPOM of cylindrical ionization chambers with high accuracy by comparing the Bragg-peak position obtained with cylindrical ionization chambers (PTW 30013, PTW 31016) to that obtained using a plane-parallel ionization chamber (PTW 34045). Results: The EPOMs of PTW 30013 and 31016 were shifted by 0.92 ± 0.07 R with R = 3.05 mm and 0.90 ± 0.14 R with R = 1.45 mm, respectively, from the reference point toward the source. Conclusions: The EPOMs obtained were greater than the value of 0.75R proposed by the IAEA TRS-398 and the analytical results.

  20. Assessment of ionization chamber correction factors in photon beams using a time saving strategy with PENELOPE code.

    PubMed

    Reis, C Q M; Nicolucci, P

    2016-02-01

    The purpose of this study was to investigate Monte Carlo-based perturbation and beam quality correction factors for ionization chambers in photon beams using a saving time strategy with PENELOPE code. Simulations for calculating absorbed doses to water using full spectra of photon beams impinging the whole water phantom and those using a phase-space file previously stored around the point of interest were performed and compared. The widely used NE2571 ionization chamber was modeled with PENELOPE using data from the literature in order to calculate absorbed doses to the air cavity of the chamber. Absorbed doses to water at reference depth were also calculated for providing the perturbation and beam quality correction factors for that chamber in high energy photon beams. Results obtained in this study show that simulations with phase-space files appropriately stored can be up to ten times shorter than using a full spectrum of photon beams in the input-file. Values of kQ and its components for the NE2571 ionization chamber showed good agreement with published values in the literature and are provided with typical statistical uncertainties of 0.2%. Comparisons to kQ values published in current dosimetry protocols such as the AAPM TG-51 and IAEA TRS-398 showed maximum percentage differences of 0.1% and 0.6% respectively. The proposed strategy presented a significant efficiency gain and can be applied for a variety of ionization chambers and clinical photon beams.

  1. Matrix:. AN Innovative Pixel Ionization Chamber for On-Line Beam Monitoring in Hadrontherapy

    NASA Astrophysics Data System (ADS)

    Braccini, S.; Pitta', G.; Donetti, M.; Cirio, R.; La Rosa, A.; Garella, M. A.; Giordanengo, S.; Marchetto, F.; Peroni, C.

    2006-04-01

    The control of intensity, position and shape of clinical beams are key issues in the treatment of tumours using hadron beams, especially in the case of active dose distribution systems. For this purpose an innovative pixel ionization chamber, named MATRIX, has been designed, constructed and tested. The chamber is conceived to be located very near the patient to precisely monitor the beam parameters used to verify the treatment planning specifications. MATRIX operates in air and is characterized by a 21 × 21 cm2 sensitive area subdivided in 1024 pixels of 6.5 × 6.5 mm2. To minimize the amount of material crossed by the beam, the anode is made of a 50 μm kapton foil, with a deposit of 17 μm copper on each side. A very sensitive electronics is used for the readout, based on a dedicated chip. In this paper the construction of the chamber and the very positive results of the first beam tests are described.

  2. Determination of small-field correction factors for cylindrical ionization chambers using a semiempirical method

    NASA Astrophysics Data System (ADS)

    Park, Kwangwoo; Bak, Jino; Park, Sungho; Choi, Wonhoon; Park, Suk Won

    2016-02-01

    A semiempirical method based on the averaging effect of the sensitive volumes of different air-filled ionization chambers (ICs) was employed to approximate the correction factors for beam quality produced from the difference in the sizes of the reference field and small fields. We measured the output factors using several cylindrical ICs and calculated the correction factors using a mathematical method similar to deconvolution; in the method, we modeled the variable and inhomogeneous energy fluence function within the chamber cavity. The parameters of the modeled function and the correction factors were determined by solving a developed system of equations as well as on the basis of the measurement data and the geometry of the chambers. Further, Monte Carlo (MC) computations were performed using the Monaco® treatment planning system to validate the proposed method. The determined correction factors (k{{Q\\text{msr}},Q}{{f\\text{smf}}, {{f}\\text{ref}}} ) were comparable to the values derived from the MC computations performed using Monaco®. For example, for a 6 MV photon beam and a field size of 1  ×  1 cm2, k{{Q\\text{msr}},Q}{{f\\text{smf}}, {{f}\\text{ref}}} was calculated to be 1.125 for a PTW 31010 chamber and 1.022 for a PTW 31016 chamber. On the other hand, the k{{Q\\text{msr}},Q}{{f\\text{smf}}, {{f}\\text{ref}}} values determined from the MC computations were 1.121 and 1.031, respectively; the difference between the proposed method and the MC computation is less than 2%. In addition, we determined the k{{Q\\text{msr}},Q}{{f\\text{smf}}, {{f}\\text{ref}}} values for PTW 30013, PTW 31010, PTW 31016, IBA FC23-C, and IBA CC13 chambers as well. We devised a method for determining k{{Q\\text{msr}},Q}{{f\\text{smf}}, {{f}\\text{ref}}} from both the measurement of the output factors and model-based mathematical computation. The proposed method can be useful in case the MC simulation would not be applicable for the clinical settings.

  3. Performance of a multi-axis ionization chamber array in a 1.5 T magnetic field

    NASA Astrophysics Data System (ADS)

    Smit, K.; Kok, J. G. M.; Lagendijk, J. J. W.; Raaymakers, B. W.

    2014-04-01

    At the UMC Utrecht a prototype MR-linac has been installed. The system consists of an 8 MV Elekta linear accelerator and a 1.5 T Philips MRI system. This paper investigates the performance of the IC PROFILER™, a multi-axis ionization chamber array, in a 1.5 T magnetic field. The influence of the magnetic field on the IC PROFILER™ reproducibility, dose response linearity, pulse rate frequency dependence, power to electronics, panel orientation and ionization chamber shape were investigated. The linearity, reproducibility, pulse rate frequency dependence, panel orientation and ionization chamber shape are unaffected by the magnetic field. When the measurements results are normalized to the centre reference chamber, the measurements can commence unaltered. Orientation of the ionization chambers in the magnetic field is of importance, therefore caution must be taken when comparing or normalizing results from several different axes. IC PROFILER™ dose profiles were compared with film dose profiles obtained simultaneously in the MR-linac. Deviation between the film and the IC PROFILER™ data was caused by the noise in the film, indicating correct performance of the IC PROFILER™ in the transverse 1.5 T magnetic field.

  4. [Theoretical investigation of the saturation correction for ionization chambers irradiated with pulsed beams of arbitrary pulse length].

    PubMed

    Karsch, Leonhard; Pawelke, Jörg

    2014-09-01

    In ionization chambers, not all released charge is collected due to the recombination of charge carriers. This effect is taken into account by the saturation correction factor kS. A physical description of the correction factor has been established for pulsed radiation. However, it is only accurate when the pulse length is short compared with the collection time of the ionization chamber. In this paper we develop a description of the saturation correction for radiation pulses of arbitrary length. For this, a system of partial differential equations is solved iteratively. The numerical solutions are verified experimentally for a Roos ionization chamber (PTW TM34001) exposed to a pulsed electron beam. The results of this iterative procedure describe the experimental data well. The calculations are also possible for beam structures which are experimentally hard to get and thereby contribute to a better understanding and correct description of the saturation correction at arbitrary pulse length. Among other things the pulse length dependent distributions of the charge carriers in the ionization chamber is calculated, inclusive of the transition to the conditions prevailing in the case of continuous irradiation. Furthermore is shown that the formula for kS established by Hochhäuser and Balk is applicable even at arbitrary pulse length, if pulse duration dependent effective values are used for the parameters a and p. These effective values have been determined for the Roos chamber at pulse lengths up to 300 μs.

  5. Monte Carlo Simulation in the Optimization of a Free-Air Ionization Chamber for Dosimetric Control in Medical Digital Radiography

    SciTech Connect

    Leyva, A.; Pinera, I.; Abreu, Y.; Cruz, C. M.; Montano, L. M.

    2008-08-11

    During the earliest tests of a free-air ionization chamber a poor response to the X-rays emitted by several sources was observed. Then, the Monte Carlo simulation of X-rays transport in matter was employed in order to evaluate chamber behavior as X-rays detector. The photons energy deposition dependence with depth and its integral value in all active volume were calculated. The obtained results reveal that the designed device geometry is feasible to be optimized.

  6. Comparison of pencil-type ionization chamber calibration results and methods between dosimetry laboratories.

    PubMed

    Hourdakis, Costas J; Büermann, Ludwig; Ciraj-Bjelac, Olivera; Csete, Istvan; Delis, Harry; Gomola, Igor; Persson, Linda; Novak, Leos; Petkov, Ivailo; Toroi, Paula

    2016-01-01

    A comparison of calibration results and procedures in terms of air kerma length product, PKL, and air kerma, K, was conducted between eight dosimetry laboratories. A pencil-type ionization chamber (IC), generally used for computed tomography dose measurements, was calibrated according to three calibration methods, while its residual signal and other characteristics (sensitivity profile, active length) were assessed. The results showed that the "partial irradiation method" is the preferred method for the pencil-type IC calibration in terms of PKL and it could be applied by the calibration laboratories successfully. Most of the participating laboratories achieved high level of agreement (>99%) for both dosimetry quantities (PKL and K). Estimated relative standard uncertainties of comparison results vary among laboratories from 0.34% to 2.32% depending on the quantity, beam quality and calibration method applied. Detailed analysis of the assigned uncertainties have been presented and discussed.

  7. Unexpected bias in NIST 4πγ ionization chamber measurements.

    PubMed

    Unterweger, M P; Fitzgerald, R

    2012-09-01

    In January of 2010, it was discovered that the source holder used for calibrations in the NIST 4πγ ionization chamber (IC) has not been stable. The positioning ring that determines the height of the sample in the reentrant tube of the IC has slowly shifted during 35 years of use. This has led to a slow change in the calibration factors for the various radionuclides measured by this instrument. The changes are dependent on γ-ray energy and the time the IC was calibrated for a given radionuclide. A review of the historic data with regard to when the calibrations were done has enabled us to approximate the magnitude of the changes with time. This requires a number of assumptions, and corresponding uncertainty components, including whether the changes in height were gradual or in steps as will be shown in drawings of sample holder. For calibrations the changes in calibration factors have been most significant for low energy gamma emitters such as (133)Xe, (241)Am, (125)I and (85)Kr. The corrections to previous calibrations can be approximated and the results corrected with an increase in the overall uncertainty. At present we are recalibrating the IC based on new primary measurements of the radionuclides measured on the IC. Likewise we have been calibrating a new automated ionization-chamber system. A bigger problem is the significant number of half-life results NIST has published over the last 35 years that are based on IC measurements. The effect on half-life is largest for long-lived radionuclei, especially low-energy γ-ray emitters. This presentation will review our results and recommend changes in values and/or uncertainties. Any recommendation for withdrawal of any results will also be undertaken.

  8. Dependence with air density of the response of the PTW SourceCheck ionization chamber for low energy brachytherapy sources

    SciTech Connect

    Tornero-López, Ana M.; Guirado, Damián; Ruiz-Arrebola, Samuel; Perez-Calatayud, Jose; Simancas, Fernando; Lallena, Antonio M.; Gazdic-Santic, Maja

    2013-12-15

    Purpose: Air-communicating well ionization chambers are commonly used to assess air kerma strength of sources used in brachytherapy. The signal produced is supposed to be proportional to the air density within the chamber and, therefore, a density-independent air kerma strength is obtained when the measurement is corrected to standard atmospheric conditions using the usual temperature and pressure correction factor. Nevertheless, when assessing low energy sources, the ionization chambers may not fulfill that condition and a residual density dependence still remains after correction. In this work, the authors examined the behavior of the PTW 34051 SourceCheck ionization chamber when measuring the air kerma strength of {sup 125}I seeds.Methods: Four different SourceCheck chambers were analyzed. With each one of them, two series of measurements of the air kerma strength for {sup 125}I selectSeed{sup TM} brachytherapy sources were performed inside a pressure chamber and varying the pressure in a range from 747 to 1040 hPa (560 to 780 mm Hg). The temperature and relative humidity were kept basically constant. An analogous experiment was performed by taking measurements at different altitudes above sea level.Results: Contrary to other well-known ionization chambers, like the HDR1000 PLUS, in which the temperature-pressure correction factor overcorrects the measurements, in the SourceCheck ionization chamber they are undercorrected. At a typical atmospheric situation of 933 hPa (700 mm Hg) and 20 °C, this undercorrection turns out to be 1.5%. Corrected measurements show a residual linear dependence on the density and, as a consequence, an additional density dependent correction must be applied. The slope of this residual linear density dependence is different for each SourceCheck chamber investigated. The results obtained by taking measurements at different altitudes are compatible with those obtained with the pressure chamber.Conclusions: Variations of the altitude and

  9. Monte Carlo aided design of an improved well-type ionization chamber for low energy brachytherapy sources

    SciTech Connect

    Bohm, Tim D.; Micka, John A.; De Werd, Larry A.

    2007-04-15

    The determination of the air kerma strength of a brachytherapy seed is necessary for effective treatment planning. Well-type ionization chambers are used on site at therapy clinics to determine the air kerma strength of seeds. In this work, an improved well-type ionization chamber for low energy, low dose rate brachytherapy sources is designed using Monte Carlo transport calculations to aid in the design process. The design improvements are the elimination of the air density induced over-response effect seen in other air-communicating chambers for low energy photon sources, and a larger signal strength (response or current) for {sup 103}Pd and {sup 125}I based seeds. A prototype well chamber based on the Monte Carlo aided design but using graphite coated acrylic walls rather than the design basis air equivalent plastic (C-552) walls was constructed and experimentally evaluated. The prototype chamber produced an 85% stronger signal when measuring a commonly used {sup 103}Pd seed and a 26% stronger signal when measuring a commonly used {sup 125}I seed when compared to another commonly used well chamber. The normalized P{sub TP} corrected chamber response is, at most, 1.3% and 2.4% over unity for air densities/pressures corresponding to an elevation of 3048 m (10 000 feet) above sea level for the commonly used {sup 103}Pd and {sup 125}I based seeds respectively. Comparing calculated and measured chamber responses for common {sup 103}Pd and {sup 125}I based brachytherapy seeds show agreement within 0.6% and 0.2%, respectively. We conclude that Monte Carlo transport calculations accurately model the response of this new well chamber and in general can be used to predict the response of well chambers. The prototype chamber built in this work responds as predicted by the Monte Carlo calculations.

  10. The magic cube and the pixel ionization chamber: detectors for monitor and dosimetry of radiotherapy beams

    NASA Astrophysics Data System (ADS)

    Amerio, S.; Boriano, A.; Bourhaleb, F.; Cirio, R.; Donetti, M.; Garelli, E.; Giordanengo, S.; Madon, E.; Marchetto, F.; Nastasi, U.; Peroni, C.; Sanz Freire, C. J.; Sardo, A.; Trevisiol, E.

    2003-09-01

    Tumor therapy takes advantage of the energy deposition of radiation to concentrate high doses in the target while sparing healthy tissue. Elective pathologies for highly conformal radiotherapies such as photon Intensity Modulated Radiotherapy (IMRT) and radiotherapy with hadrons are head and neck, eye, prostate and in general all tumors that are either deep or located close to critical organs. In the world there are several centers that are using such techniques and a common problem that is being experienced is the verification of treatment plans and monitoring of the beam. We have designed and built two detectors that allow 2D and 3D measurements of dose and fluence of such beams. The detectors allow measurements on big surfaces, up to 25∗25 cm2. The active media are parallel plate, strip and pixel segmented ionization chambers with front-end Very Large Scale Integration (VLSI) readout and PC based data acquistion. The description of dosimeter, chamber and electronics will be given with results from beam tests and therapy plan verification.

  11. Scintillation properties of N2 and CF4 and performances of a scintillating ionization chamber

    NASA Astrophysics Data System (ADS)

    Lehaut, G.; Salvador, S.; Fontbonne, J.-M.; Lecolley, F.-R.; Perronnel, J.; Vandamme, Ch.

    2015-10-01

    In this work, we studied the emission yields, decay times and coincidence resolving times (CRT) of two gases, nitrogen (N2) and tetrafluoromethane (CF4), used for particle detection in the context of fission products measurement. The set-up was made of an ionization chamber and two photomultiplier tubes (PMTs) placed front-to-front on each side of the active zone of the chamber. Using the photomultiplier tubes, the number of photoelectrons (phe) converted at the photocathodes from the scintillation processes in each gas was quantified and the scintillation time spectra were recorded. A scintillation emission yield of 24 phe MeV-1 with a decay time of τd = 2.5 ns in N2, and 225 phe MeV-1 with τd = 6.2 ns for CF4, has been measured. With our set-up, the coincidence resolving time (σ values) between the two PMTs have been measured using alpha particles at 1.4 ns and 0.34 ns for N2 and CF4, respectively.

  12. DNP for polarizing liquid {sup 3}He

    SciTech Connect

    Uemtasu, H.; Iwata, T.; Kato, S.; Michigami, T.; Ohizumi, S.; Shishido, T.; Tanaka, A.; Toyama, K.; Tajima, Y.; Yoshida, H. Y.; Kuriyama, N.

    2008-02-06

    Using DNP with zeolite powders and TEMPO, we have developed a method to enhance polarization of liquid {sup 3}He. At magnetic field of 2.5 T and a temperature of around 1.5 K, we have obatined polarization enhancement of liquid {sup 3}He, 2.34 and -1.59 for positive and negative enhancements, respectively.

  13. A two-dose-rate method for general recombination correction for liquid ionization chambers in pulsed beams

    NASA Astrophysics Data System (ADS)

    Tölli, Heikki; Sjögren, Rickard; Wendelsten, Mikael

    2010-08-01

    The correction for general recombination losses in liquid ionization chambers (LICs) is more complex than that in air-filled ionization chambers. The reason for this is that the saturation charge in LICs, i.e. the charge that escapes initial recombination, depends on the applied voltage. This paper presents a method, based on measurements at two different dose rates in a pulsed beam, for general recombination correction in LICs. The Boag theory for pulsed beams is used and the collection efficiency is determined by numerical methods which are equivalent to the two-voltage method used in dosimetry with air-filled ionization chambers. The method has been tested in experiments in water in a 20 MeV electron beam using two LICs filled with isooctane and tetramethylsilane. The dose per pulse in the electron beam was varied between 0.1 mGy/pulse and 8 mGy/pulse. The relative standard deviations of the collection efficiencies determined with the two-dose-rate method ranged between 0.1% and 1.5%. The dose-rate variations of the general recombination corrected charge measured with the LICs are in excellent agreement with the corresponding values obtained with an air-filled plane parallel ionization chamber.

  14. Correction factors for the INER-improved free-air ionization chambers calculated with the Monte Carlo method.

    PubMed

    Lin, Uei-Tyng; Chu, Chien-Hau

    2006-05-01

    Monte Carlo method was used to simulate the correction factors for electron loss and scattered photons for two improved cylindrical free-air ionization chambers (FACs) constructed at the Institute of Nuclear Energy Research (INER, Taiwan). The method is based on weighting correction factors for mono-energetic photons with X-ray spectra. The newly obtained correction factors for the medium-energy free-air chamber were compared with the current values, which were based on a least-squares fit to experimental data published in the NBS Handbook 64 [Wyckoff, H.O., Attix, F.H., 1969. Design of free-air ionization chambers. National Bureau Standards Handbook, No. 64. US Government Printing Office, Washington, DC, pp. 1-16; Chen, W.L., Su, S.H., Su, L.L., Hwang, W.S., 1999. Improved free-air ionization chamber for the measurement of X-rays. Metrologia 36, 19-24]. The comparison results showed the agreement between the Monte Carlo method and experimental data is within 0.22%. In addition, mono-energetic correction factors for the low-energy free-air chamber were calculated. Average correction factors were then derived for measured and theoretical X-ray spectra at 30-50 kVp. Although the measured and calculated spectra differ slightly, the resulting differences in the derived correction factors are less than 0.02%.

  15. Super-resolution non-parametric deconvolution in modelling the radial response function of a parallel plate ionization chamber.

    PubMed

    Kulmala, A; Tenhunen, M

    2012-11-07

    The signal of the dosimetric detector is generally dependent on the shape and size of the sensitive volume of the detector. In order to optimize the performance of the detector and reliability of the output signal the effect of the detector size should be corrected or, at least, taken into account. The response of the detector can be modelled using the convolution theorem that connects the system input (actual dose), output (measured result) and the effect of the detector (response function) by a linear convolution operator. We have developed the super-resolution and non-parametric deconvolution method for determination of the cylinder symmetric ionization chamber radial response function. We have demonstrated that the presented deconvolution method is able to determine the radial response for the Roos parallel plate ionization chamber with a better than 0.5 mm correspondence with the physical measures of the chamber. In addition, the performance of the method was proved by the excellent agreement between the output factors of the stereotactic conical collimators (4-20 mm diameter) measured by the Roos chamber, where the detector size is larger than the measured field, and the reference detector (diode). The presented deconvolution method has a potential in providing reference data for more accurate physical models of the ionization chamber as well as for improving and enhancing the performance of the detectors in specific dosimetric problems.

  16. Vortices in rotating superfluid 3He.

    PubMed

    Lounasmaa, O V; Thuneberg, E

    1999-07-06

    In this review we first present an introduction to 3He and to the ROTA collaboration under which most of the knowledge on vortices in superfluid 3He has been obtained. In the physics part, we start from the exceptional properties of helium at millikelvin temperatures. The dilemma of rotating superfluids is presented. In 4He and in 3He-B the problem is solved by nucleating an array of singular vortex lines. Their experimental detection in 3He by NMR is described next. The vortex cores in 3He-B have two different structures, both of which have spontaneously broken symmetry. A spin-mass vortex has been identified as well. This object is characterized by a flow of spins around the vortex line, in addition to the usual mass current. A great variety of vortices exist in the A phase of 3He; they are either singular or continuous, and their structure can be a line or a sheet or fill the whole liquid. Altogether seven different types of vortices have been detected in 3He by NMR. We also describe briefly other experimental methods that have been used by ROTA scientists in studying vortices in 3He and some important results thus obtained. Finally, we discuss the possible applications of experiments and theory of 3He to particle physics and cosmology. In particular, we report on experiments where superfluid 3He-B was heated locally by absorption of single neutrons. The resulting events can be used to test theoretical models of the Big Bang at the beginning of our universe.

  17. Investigation of electron-loss and photon scattering correction factors for FAC-IR-300 ionization chamber

    NASA Astrophysics Data System (ADS)

    Mohammadi, S. M.; Tavakoli-Anbaran, H.; Zeinali, H. Z.

    2017-02-01

    The parallel-plate free-air ionization chamber termed FAC-IR-300 was designed at the Atomic Energy Organization of Iran, AEOI. This chamber is used for low and medium X-ray dosimetry on the primary standard level. In order to evaluate the air-kerma, some correction factors such as electron-loss correction factor (ke) and photon scattering correction factor (ksc) are needed. ke factor corrects the charge loss from the collecting volume and ksc factor corrects the scattering of photons into collecting volume. In this work ke and ksc were estimated by Monte Carlo simulation. These correction factors are calculated for mono-energy photon. As a result of the simulation data, the ke and ksc values for FAC-IR-300 ionization chamber are 1.0704 and 0.9982, respectively.

  18. Determinations of the correction factors for small fields in cylindrical ionization chambers based on measurement and numerical calculation

    NASA Astrophysics Data System (ADS)

    Park, Kwangwoo; Choi, Wonhoon; Park, Sungho; Choi, Jin Hwa; Park, Suk Won; Bak, Jino

    2015-07-01

    We investigated the volume averaging effect for air-filled cylindrical ionization chambers to determine the correction factors in a small photon field for a given chamber. We measured output factors with several cylindrical ionization chambers, and by using a mathematical method similar to deconvolution, we modeled the non-constant and inhomogeneous exposure function in the cavity of the chamber. The parameters in the exposure function and the correction factors were determined by solving a system of equations that we had developed by using the measured data and the geometry of the given chamber. The correction factors (CFs) were very similar to those obtained from Monte Carlo (MC) simulations. For example, the CFs in this study were found to be 1.116 for PTW31010 and 1.0225 for PTW31016 while the CFs obtained from MC simulations were reported as being approximately between 1.17 and 1.20 for PTW31010 and between 1.02 and 1.06 for PTW31016 in a 6-MV photon beam of 1 × 1 cm2. Furthermore, the method of deconvolution combined with the MC result for the chamber's response function showed a similar CF for PTW 30013, which was reported as 2.29 and 1.54 for a 1 × 1 cm2 and a 1.5 × 1.5 cm2 field size, respectively. The CFs from our method were similar, 2.42 and 1.54. In addition, we report CFs for PTW30013, PTW31010, PTW31016, IBA FC23-C, and IBA CC13. As a consequence, we suggest the use of our method to measure the correct output factor by using the fact that an inhomogeneous exposure causes a volume averaging effect in the cavity of air-filled cylindrical ionization chamber. The result obtained by using our method is very similar to that obtained from MC simulations. The method we developed can easily be applied in clinics.

  19. Time-resolved dosimetry using a pinpoint ionization chamber as quality assurance for IMRT and VMAT

    SciTech Connect

    Louwe, Robert J. W. Satherley, Thomas; Day, Rebecca A.; Greig, Lynne; Wendling, Markus; Monshouwer, René

    2015-04-15

    Purpose: To develop a method to verify the dose delivery in relation to the individual control points of intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) using an ionization chamber. In addition to more effective problem solving during patient-specific quality assurance (QA), the aim is to eventually map out the limitations in the treatment chain and enable a targeted improvement of the treatment technique in an efficient way. Methods: Pretreatment verification was carried out for 255 treatment plans that included a broad range of treatment indications in two departments using the equipment of different vendors. In-house developed software was used to enable calculation of the dose delivery for the individual beamlets in the treatment planning system (TPS), for data acquisition, and for analysis of the data. The observed deviations were related to various delivery and measurement parameters such as gantry angle, field size, and the position of the detector with respect to the field edge to distinguish between error sources. Results: The average deviation of the integral fraction dose during pretreatment verification of the planning target volume dose was −2.1% ± 2.2% (1 SD), −1.7% ± 1.7% (1 SD), and 0.0% ± 1.3% (1 SD) for IMRT at the Radboud University Medical Center (RUMC), VMAT (RUMC), and VMAT at the Wellington Blood and Cancer Centre, respectively. Verification of the dose to organs at risk gave very similar results but was generally subject to a larger measurement uncertainty due to the position of the detector at a high dose gradient. The observed deviations could be related to limitations of the TPS beam models, attenuation of the treatment couch, as well as measurement errors. The apparent systematic error of about −2% in the average deviation of the integral fraction dose in the RUMC results could be explained by the limitations of the TPS beam model in the calculation of the beam penumbra. Conclusions: This

  20. Liquid ionization chamber initial recombination dependence on LET for electrons and photons.

    PubMed

    Johansson, Erik; Andersson, Jonas; Johansson, Lennart; Tölli, Heikki

    2013-06-21

    The possibility of indirect measurements of linear energy transfer (LET) with a liquid ionization chamber (LIC) has been investigated by studying initial recombination losses at different applied voltages. A linear fit is made to the voltage-signal curve and the intersection point of the fit and the voltage-axis is shown to correlate with LET. The LIC applied voltages were 100-700 V, which corresponds to electric field strengths between 0.3 and 2.0 MV m(-1). Several different photon and electron beams have been studied, and by using MCNPX™ the respective LET spectra have been determined. The beam qualities in this study were found to have a fluence averaged LET between 0.17 and 1.67 keV µm(-1) and a corresponding dose averaged LET between 0.97 and 4.62 keV µm(-1). For the experimental data in this study the linear fit method yields consistent results with respect to Monte Carlo simulated LET values. A calibration curve for LET determination is provided for the LIC used in the present work.

  1. Optimization of signal extraction and front-end design in a fast,multigap ionization chamber

    SciTech Connect

    Datte, P.S.; Manfredi, P.F.; Millaud, J.E.; Placidi, M.; Ratti,L.; Speziali, V.; Traversi, G.; Turner, W.C.

    2001-11-05

    This paper discusses the criteria that have been adopted tooptimize the signal processing in a shower detector to be employed as LHCbeam luminosity monitor. The original aspect ofthis instrument is itsablility to operate on a bunch-by-bunch basis. This means that it mustperform accurate charge measurements at a repetition rate of 40 MHz. Thedetector must withstand an integrated dose of 100 Grad, that is, two tothree orders of magnitude beyond those expected in the experiments. Tomeet the above requirements, an ionization chamber consisting of severalgaps of thickness 0.5 mm, filled with a gas that is expected to beradiation resistant, has been designed. Crucial in the development of thesystem is the signal processing, as the electronic noise may set thedominant limitation to the accuracy of the measurement. This is relatedto two aspects. One is the short time available for the chargemeasurement. The second one is the presence of a few meter cable betweenthe detector and the preamplifier, as this must be located out of theregion of highest radiation field. Therefore the optimization of thesignal-to-noise ratio requires that the best configuration of the chambergaps be determined under the constraint of the presence of a cable ofnon-negligible length between detector and preamplifier. The remoteplacement of the amplifying electronics will require that the front-endelectronics be radiation hard although to a lesser extent than thedetector.

  2. Preliminary results with a strip ionization chamber used as beam monitor for hadrontherapy treatments

    NASA Astrophysics Data System (ADS)

    Boriano, A.; Bourhaleb, F.; Cirio, R.; Cirrone, G. A. P.; Cuttone, G.; Donetti, M.; Garelli, E.; Giordanengo, S.; Luparia, A.; Marchette, F.; Peroni, C.; Raffaele, L.; Sabini, M. G.; Valastro, L.

    2006-01-01

    Preliminary results are presented from a test of a parallel plate ionization chamber with the anode segmented in strips (MOPI) to be used as a beam monitor for therapeutical treatments on the 62 MeV proton beam line of the INFN-LNS Superconducting Cyclotron. Ocular pathologies have been treated at the Catana facility since March 2002. The detector, placed downstream of the patient collimator, will allow the measurement of the relevant beam diagnostic parameters during treatment such as integrated beam fluence, for dose determination; the beam baricentre, width and asymmetry will be obtained from the fluence profile sampled with a resolution of about 100 Urn at a rate up to 1 kHz with no dead time. In this test, carried out at LNS, the detector has been exposed to different beam shapes and the integrated fluence derived by the measured beam profiles has been compared with that obtained with other dosimeters normally used for treatment. The skewness of the beam profile has been measured and shown to be suitable to on-line check variations of the beam shape.

  3. The control system of the multi-strip ionization chamber for the HIMM

    NASA Astrophysics Data System (ADS)

    Li, Min; Yuan, Y. J.; Mao, R. S.; Xu, Z. G.; Li, Peng; Zhao, T. C.; Zhao, Z. L.; Zhang, Nong

    2015-03-01

    Heavy Ion Medical Machine (HIMM) is a carbon ion cancer treatment facility which is being built by the Institute of Modern Physics (IMP) in China. In this facility, transverse profile and intensity of the beam at the treatment terminals will be measured by the multi-strip ionization chamber. In order to fulfill the requirement of the beam position feedback to accomplish the beam automatic commissioning, less than 1 ms reaction time of the Data Acquisition (DAQ) of this detector must be achieved. Therefore, the control system and software framework for DAQ have been redesigned and developed with National Instruments Compact Reconfigurable Input/Output (CompactRIO) instead of PXI 6133. The software is Labview-based and developed following the producer-consumer pattern with message mechanism and queue technology. The newly designed control system has been tested with carbon beam at the Heavy Ion Research Facility at Lanzhou-Cooler Storage Ring (HIRFL-CSR) and it has provided one single beam profile measurement in less than 1 ms with 1 mm beam position resolution. The fast reaction time and high precision data processing during the beam test have verified the usability and maintainability of the software framework. Furthermore, such software architecture is easy-fitting to applications with different detectors such as wire scanner detector.

  4. D-IMRT verification with a 2D pixel ionization chamber: dosimetric and clinical results in head and neck cancer.

    PubMed

    Stasi, M; Giordanengo, S; Cirio, R; Boriano, A; Bourhaleb, F; Cornelius, I; Donetti, M; Garelli, E; Gomola, I; Marchetto, F; Porzio, M; Sanz Freire, C J; Sardo, A; Peroni, C

    2005-10-07

    Dynamic intensity-modulated radiotherapy (D-IMRT) using the sliding-window technique is currently applied for selected treatments of head and neck cancer at Institute for Cancer Research and Treatment of Candiolo (Turin, Italy). In the present work, a PiXel-segmented ionization Chamber (PXC) has been used for the verification of 19 fields used for four different head and neck cancers. The device consists of a 32x32 matrix of 1024 parallel-plate ionization chambers arranged in a square of 24x24 cm2 area. Each chamber has 0.4 cm diameter and 0.55 cm height; a distance of 0.75 cm separates the centre of adjacent chambers. The sensitive volume of each single ionization chamber is 0.07 cm3. Each of the 1024 independent ionization chambers is read out with a custom microelectronics chip.The output factors in water obtained with the PXC at a depth of 10 cm were compared to other detectors and the maximum difference was 1.9% for field sizes down to 3x3 cm2. Beam profiles for different field dimensions were measured with the PXC and two other types of ionization chambers; the maximum distance to agreement (DTA) in the 20-80% penumbra region of a 3x3 cm2 field was 0.09 cm. The leaf speed of the multileaf collimator was varied between 0.07 and 2 cm s-1 and the detector response was constant to better than 0.6%. The behaviour of the PXC was measured while varying the dose rate between 0.21 and 1.21 Gy min-1; the mean difference was 0.50% and the maximum difference was 0.96%. Using fields obtained with an enhanced dynamic wedge and a staircase-like (step) IMRT field, the PXC has been tested for simple 1D modulated beams; comparison with film gave a maximum DTA of 0.12 cm. The PXC was then used to check four different IMRT plans for head and neck cancer treatment: cervical chordoma, parotid, ethmoid and skull base. In the comparison of the PXC versus film and PXC versus treatment planning system, the number of pixels with gamma parameter

  5. D-IMRT verification with a 2D pixel ionization chamber: dosimetric and clinical results in head and neck cancer

    NASA Astrophysics Data System (ADS)

    Stasi, M.; Giordanengo, S.; Cirio, R.; Boriano, A.; Bourhaleb, F.; Cornelius, I.; Donetti, M.; Garelli, E.; Gomola, I.; Marchetto, F.; Porzio, M.; Sanz Freire, C. J.; Sardo, A.; Peroni, C.

    2005-10-01

    Dynamic intensity-modulated radiotherapy (D-IMRT) using the sliding-window technique is currently applied for selected treatments of head and neck cancer at Institute for Cancer Research and Treatment of Candiolo (Turin, Italy). In the present work, a PiXel-segmented ionization Chamber (PXC) has been used for the verification of 19 fields used for four different head and neck cancers. The device consists of a 32 × 32 matrix of 1024 parallel-plate ionization chambers arranged in a square of 24 × 24 cm2 area. Each chamber has 0.4 cm diameter and 0.55 cm height; a distance of 0.75 cm separates the centre of adjacent chambers. The sensitive volume of each single ionization chamber is 0.07 cm3. Each of the 1024 independent ionization chambers is read out with a custom microelectronics chip. The output factors in water obtained with the PXC at a depth of 10 cm were compared to other detectors and the maximum difference was 1.9% for field sizes down to 3 × 3 cm2. Beam profiles for different field dimensions were measured with the PXC and two other types of ionization chambers; the maximum distance to agreement (DTA) in the 20-80% penumbra region of a 3 × 3 cm2 field was 0.09 cm. The leaf speed of the multileaf collimator was varied between 0.07 and 2 cm s-1 and the detector response was constant to better than 0.6%. The behaviour of the PXC was measured while varying the dose rate between 0.21 and 1.21 Gy min-1; the mean difference was 0.50% and the maximum difference was 0.96%. Using fields obtained with an enhanced dynamic wedge and a staircase-like (step) IMRT field, the PXC has been tested for simple 1D modulated beams; comparison with film gave a maximum DTA of 0.12 cm. The PXC was then used to check four different IMRT plans for head and neck cancer treatment: cervical chordoma, parotid, ethmoid and skull base. In the comparison of the PXC versus film and PXC versus treatment planning system, the number of pixels with γ parameter <=1 was 97.7% and 97

  6. Investigation of the initial and volume recombination losses in gamma versatile cylindrical ionization chamber VGIC developed for gamma ray dosimetry

    SciTech Connect

    Fares, M.; Mameri, S.; Abdlani, I.; Negara, K.

    2015-07-01

    A versatile Gamma ionization chambers are used for flow control in systems with gamma nuclear reactors and reprocessing plants in and monitoring atmosphere around these facilities, this in order to protect staff. In the Laboratory Detection and Measures (LDM) Division for Study and Development of Nuclear Instrumentation (DSDNI) of CRNB, we designed, developed and characterized a versatile gamma ionization chamber (VGIC) to study experimentally its characteristics according to the geometry of the electrodes, the volume and pressure of the filler gas for the design of a gamma sealed chamber. The tests were conducted under the IEC (International Electro-technical Commission). In this paper, we present the results obtained in the various nuclear tests for characterization and calibration that we have made on the ionization chamber gamma VGIC prototype developed at our Department. To do this, three irradiators were operated at the Laboratory Calibration (SSDL) of the Department of Medical Physics Nuclear Research Center of Algiers (CRNA). Irradiator intensive gamma ({sup 60}Co: 1.25 MeV), one medium intensity gamma ({sup 137}Cs: 0.662 MeV) and 3rd low intensity ({sup 60}Co). Saturation curves and linearity were identified and the operating range and the sensitivity of the chamber have been deducted. The (I,V) characteristics of the chamber filled, with argon gas at 3 bar (0.3 M pa) pressure, for gamma ray irradiator sources were studied. To do so, the chamber was irradiated with gamma rays using different numbers of gamma sources (i.e. Up to 5). The plateau region is reached above 200 V and the detector operating voltage is found to be 600 V. It is observed that in the plateau region the slope is constant with an increase in the exposure rate. The (1/I, 1/V) and (I, l/V{sup 2}) characteristic curves reveal the presence of the initial and volume recombination losses. The volume recombination losses are found to be smaller than the initial recombination losses. Finally

  7. Determination of the thermal neutron flux in a fast neutron beam by use of a boron-coated ionization chamber.

    PubMed

    Lüdemann, L; Matzen, T; Matzke, M; Schmidt, R; Scobel, W

    1995-11-01

    The thermal neutron distribution in slow and fast neutron beams is usually determined using the foil activation method. In this work a small magnesium walled ionization chamber, in which the inner surface of the wall has been coated with 10B to increase the sensitivity for thermal neutrons, is used to estimate the thermal neutron component of the beam. After calibration and determination of the directional response in a thermal neutron beam a comparison with foil activation at different depths in water was performed to investigate the reliability of the ionization measurements. The chamber was used in a computer controlled water phantom to measure the depth and lateral distribution of the thermal neutron dose. With this arrangement two-dimensional scans of the thermal neutrons could be performed quickly and with high accuracy.

  8. Zircon 4He/3He thermochronometry

    NASA Astrophysics Data System (ADS)

    Tripathy-Lang, Alka; Fox, Matthew; Shuster, David L.

    2015-10-01

    Multiple thermochronometric methods are often required to constrain time-continuous rock exhumation for studying tectonic processes or development of km-scale topography at Earth's surface. Here, we explore 4He/3He thermochronometry of zircon as a method for constraining continuous time-temperature (t-T) paths of individual samples through a temperature range that is complementary to methods such as 40Ar/39Ar thermochronometry of K-feldspar and 4He/3He thermochronometry of apatite. For different cooling rates and diffusion domain size, the temperature sensitivity of zircon 4He/3He thermochronometry ranges from slightly less than 100 °C to slightly greater than 250 °C; a typical sample provides continuous thermal constraints over ∼100 °C within that range. Outside these temperatures, 4He in zircon will either be quantitatively retained or completely lost by volume diffusion. As proof-of-concept, we present stepwise release 4He/3He spectra and associated U and Th concentration maps measured by laser ablation ICP-MS analysis of individual crystal aliquots of Fish Canyon Tuff (FCT) zircon and of a more complex setting in the Sierra Nevada batholith that experienced reheating from a proximal basaltic intrusion, the Little Devil's Postpile (LDP). The FCT zircon 4He/3He release spectra are consistent with a 4He spatial distribution dominated by alpha-ejection from crystal surfaces. The spatial distributions of U and Th measured in the same crystals do not substantially influence 4He/3He release spectra that are predicted for the known thermal history, even when incorporating spatially variable diffusivity due to accumulation of radiation damage. Conversely, the LDP 4He/3He release spectra are strongly influenced by the observed parent nuclide zonation. A three-dimensional (3D) numerical model of 4He production and diffusion, which incorporates crystal geometry, U and Th zonation, and spatially variable He diffusion kinetics, substantially improves the fit between

  9. The stability of liquid-filled matrix ionization chamber electronic portal imaging devices for dosimetry purposes.

    PubMed

    Louwe, R J W; Tielenburg, R; van Ingen, K M; Mijnheer, B J; van Herk, M B

    2004-04-01

    This study was performed to determine the stability of liquid-filled matrix ionization chamber (LiFi-type) electronic portal imaging devices (EPID) for dosimetric purposes. The short- and long-term stability of the response was investigated, as well as the importance of factors influencing the response (e.g., temperature fluctuations, radiation damage, and the performance of the electronic hardware). It was shown that testing the performance of the electronic hardware as well as the short-term stability of the imagers may reveal the cause of a poor long-term stability of the imager response. In addition, the short-term stability was measured to verify the validity of the fitted dose-response curve immediately after beam startup. The long-term stability of these imagers could be considerably improved by correcting for room temperature fluctuations and gradual changes in response due to radiation damage. As a result, the reproducibility was better than 1% (1 SD) over a period of two years. The results of this study were used to formulate recommendations for a quality control program for portal dosimetry. The effect of such a program was assessed by comparing the results of portal dosimetry and in vivo dosimetry using diodes during the treatment of 31 prostate patients. The improvement of the results for portal dosimetry was consistent with the deviations observed with the reproducibility tests in that particular period. After a correction for the variation in response of the imager, the average difference between the measured and prescribed dose during the treatment of prostate patients was -0.7%+/-1.5% (1 SD), and -0.6%+/-1.1% (1 SD) for EPID and diode in vivo dosimetry, respectively. It can be concluded that a high stability of the response can be achieved for this type of EPID by applying a rigorous quality control program.

  10. Coherent Photoproduction of pi^+ from 3/^He

    SciTech Connect

    Rakhsha Nasseripour, Barry Berman

    2011-03-01

    We have measured the differential cross section for the $\\gamma$$^3$He$\\rightarrow \\pi^+ t$ reaction. This reaction was studied using the CEBAF Large Acceptance Spectrometer (CLAS) at Jefferson Lab. Real photons produced with the Hall-B bremsstrahlung tagging system in the energy range from 0.50 to 1.55 GeV were incident on a cryogenic liquid $^3$He target. The differential cross sections for the $\\gamma$$^3$He$\\rightarrow \\pi^+ t$ reaction were measured as a function of photon-beam energy and pion-scattering angle. Theoretical predictions to date cannot explain the large cross sections except at backward angles, showing that additional components must be added to the model.

  11. Superfluid 3He in ``nematically ordered'' aerogel

    NASA Astrophysics Data System (ADS)

    Dmitriev, Vladimir

    2014-03-01

    Liquid 3He immersed in aerogel allows investigation of the influence of impurities on unconventional superfluidity. In most of such experiments silica aerogels are used. These aerogels consist of thin strands which form a ``wisp.'' Although it is established that superfluid phases of 3He in silica aerogels (A-like and B-like) have the same order parameters as A and B phases of bulk 3He, many new phenomena were observed. In particular, it was found that global anisotropy of aerogel (e.g. caused by squeezing or stretching) can orient the order parameter. Depending on prehistory and on the type of the anisotropy the A-like phase may be homogeneous or in a state with random orbital part of the order parameter. Theory predicts that a large stretching anisotropy may even influence the order parameter structure: polar phase (or A phase with polar distortion), which are not realized in bulk 3He, may become more favorable than pure A phase. Large stretching anisotropy is hardly achievable in silica aerogel. Therefore in experiments described in the talk we used a new type of aerogel, consisting of Al2O3 . H2O strands which are parallel to each other, i.e. this aerogel may be considered as infinitely stretched. We found that the superfluid phase diagram of 3He in such ``nematically ordered'' aerogel is different from the case of 3He in silica aerogel and that both observed A and B phases have large polar distortion. This distortion is larger at low pressures and grows on warming. There are indications that a pure polar phase appears near the superfluid transition temperature. Recent results will be also presented.

  12. The multiuniverse transition in superfluid 3He

    NASA Astrophysics Data System (ADS)

    Bunkov, Yury

    2013-10-01

    The symmetry-breaking phase transitions of the universe and of superfluid 3He may lead to the formation of different states with different order parameters. In both cases the energy potential below the transition temperature has a complicated multidimensional profile with many local minima and saddle points, which correspond to different states. Consequently, not only topological defects, but also islands of different metastable states can be created. Using 3He we can analyse the properties and experimental consequences of such transitions and, in particular, the first-order phase transition between the two low symmetry states.

  13. The multiuniverse transition in superfluid 3He.

    PubMed

    Bunkov, Yury

    2013-10-09

    The symmetry-breaking phase transitions of the universe and of superfluid (3)He may lead to the formation of different states with different order parameters. In both cases the energy potential below the transition temperature has a complicated multidimensional profile with many local minima and saddle points, which correspond to different states. Consequently, not only topological defects, but also islands of different metastable states can be created. Using (3)He we can analyse the properties and experimental consequences of such transitions and, in particular, the first-order phase transition between the two low symmetry states.

  14. Use of a novel two-dimensional ionization chamber array for pencil beam scanning proton therapy beam quality assurance.

    PubMed

    Lin, Liyong; Kang, Minglei; Solberg, Timothy D; Mertens, Thierry; Baeumer, Christian; Ainsley, Christopher G; McDonough, James E

    2015-05-08

    The need to accurately and efficiently verify both output and dose profiles creates significant challenges in quality assurance of pencil beam scanning (PBS) proton delivery. A system for PBS QA has been developed that combines a new two-dimensional ionization chamber array in a waterproof housing that is scanned in a water phantom. The MatriXX PT has the same detector array arrangement as the standard MatriXX(Evolution) but utilizes a smaller 2 mm plate spacing instead of 5mm. Because the bias voltage of the MatriXX PT and Evolution cannot be changed, PPC40 and FC65-G ionization chambers were used to assess recombination effects. The PPC40 is a parallel plate chamber with an electrode spacing of 2mm, while the FC65-G is a Farmer chamber FC65-G with an electrode spacing of 2.8 mm. Three bias voltages (500, 200, and 100 V) were used for both detectors to determine which radiation type (continuous, pulse or pulse-scanned beam) could closely estimate Pion from the ratios of charges collected. In comparison with the MatriXX(Evolution), a significant improvement in measurement of absolute dose with the MatriXX PT was observed. While dose uncertainty of the MatriXX(Evolution) can be up to 4%, it is < 1% for the MatriXX PT. Therefore the MatriXX(Evolution) should not be used for QA of PBS for conditions in which ion recombination is not negligible. Farmer chambers should be used with caution for measuring the absolute dose of PBS beams, as the uncertainty of Pion can be > 1%; chambers with an electrode spacing of 2 mm or smaller are recommended.

  15. Use of a novel two-dimensional ionization chamber array for pencil beam scanning proton therapy beam quality assurance.

    PubMed

    Lin, Liyong; Kang, Minglei; Solberg, Timothy D; Mertens, Thierry; Baumer, Christian; Ainsley, Christopher G; McDonough, James E

    2015-05-01

    The need to accurately and efficiently verify both output and dose profiles creates significant challenges in quality assurance of pencil beam scanning (PBS) proton delivery. A system for PBS QA has been developed that combines a new two-dimensional ionization chamber array in a waterproof housing that is scanned in a water phantom. The MatriXX PT has the same detector array arrangement as the standard MatriXXEvolution but utilizes a smaller 2 mm plate spacing instead of 5 mm. Because the bias voltage of the MatriXX PT and Evolution cannot be changed, PPC40 and FC65-G ionization chambers were used to assess recombination effects. The PPC40 is a parallel plate chamber with an electrode spacing of 2 mm, while the FC65-G is a Farmer chamber FC65-G with an electrode spacing of 2.8 mm. Three bias voltages (500, 200, and 100 V) were used for both detectors to determine which radiation type (continuous, pulse or pulse-scanned beam) could closely estimate Pion from the ratios of charges collected. In comparison with the MatriXXEvolution, a significant improvement in measurement of absolute dose with the MatriXX PT was observed. While dose uncertainty of the MatriXXEvolution can be up to 4%, it is <1% for the MatriXX PT. Therefore the MatriXXEvolution should not be used for QA of PBS for conditions in which ion recombination is not negligible. Farmer chambers should be used with caution for measuring the absolute dose of PBS beams, as the uncertainty of Pion can be <1%; chambers with an electrode spacing of 2 mm or smaller are recommended. PACS number: 87.53.Qc.

  16. DETECTORS AND EXPERIMENTAL METHODS: Design and construction of the first prototype ionization chamber for CSNS and PA beam loss monitor (BLM) system

    NASA Astrophysics Data System (ADS)

    Xu, Mei-Hang; Tian, Jian-Min; Chen, Chang; Chen, Yuan-Bo; Xu, Tao-Guang; Lu, Shuang-Tong

    2009-02-01

    Design and construction of the first prototype ionization chamber for CSNS and Proton Accelerator (PA) beam loss monitor (BLM) system is reported. The low leakage current (<0.1 pA), good plateau (approx800 V) and linearity range up to 200 Roentgen/h are obtained in the first prototype. All of these give us good experience for further improving the ionization chamber construction.

  17. Experimental determination of the effective point of measurement of cylindrical ionization chambers for high-energy photon and electron beams.

    PubMed

    Huang, Yanxiao; Willomitzer, Christian; Zakaria, Golam Abu; Hartmann, Guenther H

    2010-01-01

    Measurements of depth-dose curves in water phantom using a cylindrical ionization chamber require that its effective point of measurement is located at the measuring depth. Recommendations for the position of the effective point of measurement with respect to the central axis valid for high-energy electron and photon beams are given in dosimetry protocols. According to these protocols, the use of a constant shift P(eff) is currently recommended. However, this is still based on a very limited set of experimental results. It is therefore expected that an improved knowledge of the exact position of the effective point of measurement will further improve the accuracy of dosimetry. Recent publications have revealed that the position of the effective point of measurement is indeed varying with beam energy, field size and also with chamber geometry. The aim of this study is to investigate whether the shift of P(eff) can be taken to be constant and independent from the beam energy. An experimental determination of the effective point of measurement is presented based on a comparison between cylindrical chambers and a plane-parallel chamber using conventional dosimetry equipment. For electron beams, the determination is based on the comparison of halfvalue depth R(50) between the cylindrical chamber of interest and a well guarded plane-parallel Roos chamber. For photon beams, the depth of dose maximum, d(max), the depth of 80% dose, d(80), and the dose parameter PDD(10) were used. It was again found that the effective point of measurement for both, electron and photon beams Dosimetry, depends on the beam energy. The deviation from a constant value remains very small for photons, whereas significant deviations were found for electrons. It is therefore concluded that use of a single upstream shift value from the centre of the cylindrical chamber as recommended in current dosimetry protocols is adequate for photons, however inadequate for accurate electron beam dosimetry.

  18. Neutron Polarizers Based on Polarized 3He

    SciTech Connect

    William M. Snow

    2005-05-01

    The goal of this work, which is a collaborative effort between Indiana University, NIST, and Hamilton College, is to extend the technique of polarized neutron scattering into new domains by the development and application of polarized 3He-based neutron spin filters. After the IPNS experiment which measured Zeeman sp[litting in surface scattered neutrons using a polarized 3He cell as a polarization analyzer transporterd by car from Bloomington to Chicago, the Indiana work focused on technical developments to improve the 3He polarization of the Indiana compression system. The compression system was rebuilt with a new valve system which allows gas trapped in the dead volume of the compressors at the end of the piston stroke to be exhausted and conducted back to the optical pumping cell where it can be repolarized. We also incorporated a new intermediate storage volume made at NIST from 1720 glass which will reduce polarization losses between the compressors. Furthermore, we improved the stability of the 1083 nm laser by cooling the LMA rod. We achieved 60% 3he polarization in the optical pumping cell and 87% preservation of the polarization during compression. In parallel we built a magnetically-shielded transport solenoid for use on neutron scattering instruments such as POSY which achieves a fractional field uniformity of better than 10-3 per cm. The field was mapped using an automated 3D field mapping system for in-situ measurement of magnetic field gradients Diluted magnetic semiconductors offer many exciting opportunities for investigation of spintronic effects in solids and are certain to be one of the most active areas of condensed matter physics over then next several years. These materials can act as efficient spin injectors for devices that make use of spin-dependent transport phenomena. We just (late July 2002) finished a neutron reflectivity experiment at NIST on a GaMnAs trilayer film. This material is a ferromagnetic semiconductor which is of interest

  19. SU-E-T-415: An Ionization Chamber Array with High Spatial Resolution for External Beam Radiotherapy

    SciTech Connect

    Togno, M; Wilkens, J; Menichelli, D

    2014-06-01

    Purpose: To characterize an ionization chamber array technology with high spatial resolution and high charge collection efficiency for external beam radiotherapy. Methods: The prototype under test is a linear array of air vented ionization chambers developed by IBA Dosimetry, consisting of 80 pixels with 3.5mm spatial resolution and 4mm{sup 3} sensitive volume. The detector was characterized in a plastic phantom with {sup 60} Co radiation and MV X-rays from an ELEKTA Agility LINAC (with flattened and unflattened beam qualities). Bias voltage was varied in order to evaluate charge collection efficiency. A commercial array of ionization chambers (MatriXX Evolution, IBA Dosimetry) and an amorphous silicon flat panel in direct conversion configuration were used as references. Results: Repeatability (0.4%) and stability under continuous gamma irradiation (0.3%) are very good, in spite of low active volume and sensitivity (∼200pC/Gy). Charge collection efficiency is higher than 99% already at 150V with ∼2mGy dose per pulse, leading to a ±1.1% sensitivity change with dose per pulse in the range 0.09-2mGy (covering all flattened and unflattened applications). Measured dose profiles are in agreement with MatriXX for fields larger than 2×2cm{sup 2}, in which case the linear array offers a much better characterization of the penumbra region. Down to 1×1cm{sup 2}, measured profiles are in very good agreement with the flat panel. Conclusion: The array represents a valuable tool for the characterization of treatment fields in which high spatial resolution is required, together with the dosimetric performance of air vented ionization chambers. Such a technology would be particularly valuable in association with advanced treatment modalities such as rotational radiotherapy, stereotactic treatments (even with unflattened beam qualities) and proton therapy, due to the insensitivity of the chambers on dose per pulse. In the future, a two dimensional prototype based on this

  20. 3He: cosmological and atomic physics experiments.

    PubMed

    Bunkov, Yuriy M

    2008-08-28

    Because the superfluid 3He order parameter exhibits many similarities with that of our Universe, the superfluid condensate may be considered as a quantum vacuum that carries various types of quasiparticles and topological defects. The condensate thus provides a test system for the experimental investigation of many general physics problems in cosmology, atomic or nuclear physics that are otherwise difficult or even impossible to investigate experimentally.

  1. Patient specific quality assurance of RapidArc pre treatment plans using semiflex 0.125 cc ionization chamber

    NASA Astrophysics Data System (ADS)

    Kumar, S. A. Syam; Vivekanandan, Nagarajan

    2017-01-01

    Patient specific pre-treatment quality assurance for RapidArc plans were analyzed for hundred patients for different sites. Verification plan was created for each treatment plan in Eclipse 8.6 treatment planning system with the semiflex ionization chamber and the octavius phantom. Absolute point dose were measured for head and neck, thorax and abdomen cases using semiflex (0.125 cc) ionization chamber. Positive absolute mean dose variation of 0.56% was observed with thorax cases with a standard deviation (SD) of ±1.13 between the plans with a range of -1.78% to 2.70%. Negative percentage dose errors were found with head and neck and abdomen cases, with a mean variation of -0.43% (SD±1.50), (range -3.25% to 2.85%) and -0.35% (SD±1.48), (range -3.10% to 2.65%) for head and neck and abdomen cases respectively. Evaluation has been done using PTW verisoft software by keeping the passing criteria as 3 mm DTA, 3% DD, for 95% of the evaluated dose points. The maximum percentage value failed in gamma analysis was found to be 4.95, 4.75, and 4.88 for head and neck, thorax, and abdomen cases respectively. In all the cases analyzed the percentage dose points failed the gamma criteria is less than 5%. On the basis of the studies performed it can be concluded that the semiflex ionization chamber having a volume of 0.125 cc can be used efficiently for measuring the pre-treatment quality assurance of RapidArc plans for all the sites.

  2. Particle identification in a LKr ionization chamber by multiple induced current measurements using the shape analysis of the signal

    NASA Astrophysics Data System (ADS)

    Diaferia, R.; Lanni, F.; Maggi, B.; Palombo, F.; Sala, A.; Cantoni, P.; Frabetti, P. L.; Stagni, L.

    1996-01-01

    Charged particle (π/K) separation in the momentum range 0.5-0.7 GeV/c using a new method of shape analysis of the signal from a liquid krypton ionization chamber has been studied experimentally. The detector has been exposed to pions and protons at the T11 test beam at CERN PS. The shape of preamplifier output signal has been recorded by a waveform digitizer and differentiated to obtain multiple measurements of induced current inside a 2 cm gap. Results on particle separation are presented and compared with a Monte Carlo simulation.

  3. Particle identification in a LKr ionization chamber by multiple induced current measurements using the shape analysis of the signal

    NASA Astrophysics Data System (ADS)

    Cantoni, P.; Frabetti, P. L.; Stagni, L.; Diaferia, R.; Lanni, F.; Maggi, B.; Palombo, F.; Sala, A.; Manfredi, P. F.; Re, V.; Speziali, V.

    1995-02-01

    Charged particle ( {π}/{K}) separation in the momentum range 0.5-0.7 GeV/ c using a new method of shape analysis of the signal from a liquid krypton ionization chamber has been studied experimentally. The detector has been exposed to the T11 test beam at CERN PS. The shape of the preamplifier output signal has been recorded by a waveform digitizer and differentiated to obtain multiple measurements of induced current inside a 2 cm gap. Results on particle separation are presented.

  4. Correction factors for ionization chamber dosimetry in CyberKnife: Machine-specific, plan-class, and clinical fields

    SciTech Connect

    Gago-Arias, Araceli; Antolin, Elena; Fayos-Ferrer, Francisco; Simon, Rocio; Gonzalez-Castano, Diego M.; Palmans, Hugo; Sharpe, Peter; Gomez, Faustino; Pardo-Montero, Juan

    2013-01-15

    Purpose: The aim of this work is the application of the formalism for ionization chamber reference dosimetry of small and nonstandard fields [R. Alfonso, P. Andreo, R. Capote, M. S. Huq, W. Kilby, P. Kjaell, T. R. Mackie, H. Palmans, K. Rosser, J. Seuntjens, W. Ullrich, and S. Vatnitsky, 'A new formalism for reference dosimetry of small and nonstandard fields,' Med. Phys. 35, 5179-5186 (2008)] to the CyberKnife robotic radiosurgery system. Correction factors for intermediate calibration fields, a machine-specific reference field (msr) and two plan-class specific reference fields (pcsr), have been studied. Furthermore, the applicability of the new formalism to clinical dosimetry has been analyzed through the investigation of two clinical treatments. Methods: PTW31014 and Scanditronix-Wellhofer CC13 ionization chamber measurements were performed for the fields under investigation. Absorbed dose to water was determined using alanine reference dosimetry, and experimental correction factors were calculated from alanine to ionization chamber readings ratios. In addition, correction factors were calculated for the intermediate calibration fields and one of the clinical treatment fields using the Monte Carlo method and these were compared with the experimental values. Results: Overall correction factors deviating from unity by approximately 2% were obtained from both measurements and simulations, with values below and above unity for the studied intermediate calibration fields and clinical fields for the ionization chambers under consideration. Monte Carlo simulations yielded correction factors comparable with those obtained from measurements for the machine-specific reference field, although differences from 1% to 3.3% were observed between measured and calculated correction factors for the composite intermediate calibration fields. Dose distribution inhomogeneities are thought to be responsible for such discrepancies. Conclusions: The differences found between overall

  5. Dosimetric Verification and Validation of Conformal and IMRT Treatments Fields with an Ionization Chamber 2D-Array

    SciTech Connect

    Evangelina, Figueroa M.; Gabriel, Resendiz G.; Miguel, Perez P.

    2008-08-11

    A three-dimensional treatment planning system requires comparisons of calculated and measured dose distributions. It is necessary to confirm by means of patient specific QA that the dose distributions are correctly calculated, and that the patient data is correctly transferred to and delivered by the treatment machine. We used an analysis software for bi-dimensional dosimetric verification of conformal treatment and IMRT fields using as objective criterion the gamma index. An ionization chamber bi-dimensional array was used for absolute dose measurement in the complete field area.

  6. A method for measuring the electron drift velocity in working gas using a Frisch-grid ionization chamber

    NASA Astrophysics Data System (ADS)

    Bai, Huaiyong; Wang, Zhimin; Zhang, Luyu; Chen, Jinxiang; Zhang, Guohui

    2016-12-01

    A method for measuring the electron drift velocity in working gas is proposed. Based on the cathode and the anode signal waveforms of the Frisch-grid ionization chamber, the electron drift velocity is extracted. With this method, the electron drift velocities in Ar + 10% CH4, Ar + 3.5% CO2 and Kr + 2.7% CO2 gases have been measured and the results are compared with the existing measurements and the simulating results. Using this method, the electron drift velocity can be monitored throughout the experiment of charged particle without bothering the measurement of other parameters, such as the energy and orientation.

  7. Discovery of multiple, ionization-created CS{sub 2} anions and a new mode of operation for drift chambers

    SciTech Connect

    Snowden-Ifft, Daniel P.

    2014-01-15

    This paper focuses on the surprising discovery of multiple species of ionization-created CS{sub 2} anions in gas mixtures containing electronegative CS{sub 2} and O{sub 2}, identified by their slightly different drift velocities. Data are presented to understand the formation mechanism and identity of these new anions. Regardless of the micro-physics, however, this discovery offers a new, trigger-less mode of operation for the drift chambers. A demonstration of trigger-less operation is presented.

  8. Coupling between Solid 3He on Aerogel and Superfluid 3He in the Low Temperature Limit

    SciTech Connect

    Bradley, D. I.; Fisher, S. N.; Guenault, A. M.; Haley, R. P.; Pickett, G. R.; Tsepelin, V.; Whitehead, R. C. V.; Skyba, P.

    2006-09-07

    We have cooled liquid 3He contained in a 98% open aerogel sample surrounded by bulk superfluid 3He-B at zero pressure to below 120 {mu}K. The aerogel sample is placed in a quasiparticle blackbody radiator cooled by a Lancaster-style nuclear cooling stage to {approx}200 {mu}K. We monitor the temperature of the 3He inside the blackbody radiator using a vibrating wire resonator. We find that reducing the magnetic field on the aerogel sample causes substantial cooling of all the superfluid inside the blackbody radiator. We believe this is due to the demagnetization of the solid 3He layers on the aerogel strands. This system has potential for achieving extremely low temperatures in the confined fluid.

  9. Direct determination of k Q for Farmer-type ionization chambers in a clinical scanned carbon ion beam using water calorimetry.

    PubMed

    Osinga-Blättermann, J-M; Brons, S; Greilich, S; Jäkel, O; Krauss, A

    2017-03-21

    Until now, the dosimetry of carbon ions with ionization chambers has not reached the same level of accuracy as that of high-energy photons. This is mainly caused by the approximately threefold larger uncertainty of the k Q factor of ionization chambers, which, due to the lack of experimental data, is still derived by calculations. Measurements of absorbed dose to water, D w, by means of water calorimetry have now been performed in the entrance channel of a scanned 6 cm  ×  6 cm radiation field of 429 MeV/u carbon ions, allowing the direct calibration of ionization chambers and thus the experimental determination of k Q. Within this work, values for k Q have been determined for the Farmer-type ionization chambers FC65-G and TM30013. A detailed investigation of the radiation field enabled the accurate determination of correction factors needed for both calorimetric and ionometric measurements. Finally, a relative standard measurement uncertainty of 0.8% (k  =  1) could be achieved for the experimental k Q values. For both chambers, the experimental k Q factors were found to be about 1% larger than those tabulated in the German DIN 6801-1 protocol, whereas compared to the theoretical values stated in the TRS-398 protocol, the experimental k Q value agrees within 0.4% for the TM30013 chamber but is about 1% lower in the case of the FC65-G chamber.

  10. Direct determination of k Q for Farmer-type ionization chambers in a clinical scanned carbon ion beam using water calorimetry

    NASA Astrophysics Data System (ADS)

    Osinga-Blättermann, J.-M.; Brons, S.; Greilich, S.; Jäkel, O.; Krauss, A.

    2017-03-01

    Until now, the dosimetry of carbon ions with ionization chambers has not reached the same level of accuracy as that of high-energy photons. This is mainly caused by the approximately threefold larger uncertainty of the k Q factor of ionization chambers, which, due to the lack of experimental data, is still derived by calculations. Measurements of absorbed dose to water, D w, by means of water calorimetry have now been performed in the entrance channel of a scanned 6 cm  ×  6 cm radiation field of 429 MeV/u carbon ions, allowing the direct calibration of ionization chambers and thus the experimental determination of k Q. Within this work, values for k Q have been determined for the Farmer-type ionization chambers FC65-G and TM30013. A detailed investigation of the radiation field enabled the accurate determination of correction factors needed for both calorimetric and ionometric measurements. Finally, a relative standard measurement uncertainty of 0.8% (k  =  1) could be achieved for the experimental k Q values. For both chambers, the experimental k Q factors were found to be about 1% larger than those tabulated in the German DIN 6801-1 protocol, whereas compared to the theoretical values stated in the TRS-398 protocol, the experimental k Q value agrees within 0.4% for the TM30013 chamber but is about 1% lower in the case of the FC65-G chamber.

  11. NOTE: The calibration of parallel-plate electron ionization chambers at NPL for use with the IPEM 2003 code of practice: summary data

    NASA Astrophysics Data System (ADS)

    Bass, Graham; Thomas, Russell; Pearce, Julia

    2009-04-01

    The most recent electron dosimetry code of practice for radiotherapy written by the Institute of Physics and Engineering in Medicine was published in 2003 and is based on the NPL electron absorbed dose to water calibration service. NPL has calibrated many Scanditronix type NACP-02 and PTW Roos type 34001 parallel plate ionization chambers in terms of absorbed dose to water, for use with the code of practice. The results of the calibrations of these chamber types summarized here include the absorbed dose to water sensitivity, where the mean calibration factor standard deviations are 5.8% for NACP-02 chambers and 1.1% for PTW Roos chambers. The correction for the polarity effect is shown to be small (less than 0.2% for all beam qualities) but with a discernible beam quality dependence. The correction for recombination is shown to be consistent and reproducible, and an analysis of these results suggests that the plate separation of the NACP-02 chambers is more variable from chamber to chamber than with the PTW Roos chambers. The calibration of these chambers is shown to be repeatable within ±0.2% over 2-3 years. It is also shown that check source measurements can be repeated within ±0.3% over several years. The results justify the use of NACP-02 and PTW 34001 chambers as secondary standards, but also indicate that the PTW 34001 chambers show less variation from chamber to chamber.

  12. The calibration of parallel-plate electron ionization chambers at NPL for use with the IPEM 2003 code of practice: summary data.

    PubMed

    Bass, Graham; Thomas, Russell; Pearce, Julia

    2009-04-21

    The most recent electron dosimetry code of practice for radiotherapy written by the Institute of Physics and Engineering in Medicine was published in 2003 and is based on the NPL electron absorbed dose to water calibration service. NPL has calibrated many Scanditronix type NACP-02 and PTW Roos type 34001 parallel plate ionization chambers in terms of absorbed dose to water, for use with the code of practice. The results of the calibrations of these chamber types summarized here include the absorbed dose to water sensitivity, where the mean calibration factor standard deviations are 5.8% for NACP-02 chambers and 1.1% for PTW Roos chambers. The correction for the polarity effect is shown to be small (less than 0.2% for all beam qualities) but with a discernible beam quality dependence. The correction for recombination is shown to be consistent and reproducible, and an analysis of these results suggests that the plate separation of the NACP-02 chambers is more variable from chamber to chamber than with the PTW Roos chambers. The calibration of these chambers is shown to be repeatable within +/-0.2% over 2-3 years. It is also shown that check source measurements can be repeated within +/-0.3% over several years. The results justify the use of NACP-02 and PTW 34001 chambers as secondary standards, but also indicate that the PTW 34001 chambers show less variation from chamber to chamber.

  13. Neutron scattering from solid 3He

    NASA Astrophysics Data System (ADS)

    Schanen, R.; Sherline, T. E.; Toader, A. M.; Boyko, V.; Mat'as, S.; Meschke, M.; Schöttl, S.; Adams, E. D.; Cowan, B.; Godfrin, H.; Goff, J. P.; Roger, M.; Saunders, J.; Siemensmeyer, K.; Takano, Y.

    2003-05-01

    Multiple spin exchange leads, according to present understanding, to a variety of magnetically ordered states in solid 3He, depending on pressure and applied magnetic field. We report the status of experiments to directly determine these structures by neutron scattering. The large neutron absorption cross section, and associated sample heating, impose severe experimental demands on the design of the sample cell. We report on our proposed solution, including details of the sintered heat exchanger necessary to cool the sample, as well as the PrNi 5 nuclear demagnetization stage. The use of NMR in parallel experiments to characterise growth of the solid sample within the sinter is also discussed.

  14. Intense polarized /sup 3/He ion source

    SciTech Connect

    Slobodrian, R.J.; Bertrand, R.; Grioux, J.; Labrie, R.; Lapainte, R.; Meunier, J.F.; Pigeon, G.; Pouliot, L.; Rioux, C.; Roy, R.

    1985-10-01

    This source is based on the atomic polarization of the 2/sup 3/S/sub 1/ metastable state of the neutral atom. A version suitable for operation on the high voltage terminal of a CN Van de Graaff has been constructed, bench tested and installed in the terminal of a 7.5 MV machine. The polarization of the atomic beam is higher than 90%. It is now fully operational and a current of /sup 3/He/sup +/ of 300 nA has been measured after acceleration.

  15. General collection efficiency for liquid isooctane and tetramethylsilane used as sensitive media in a parallel-plate ionization chamber.

    PubMed

    Johansson, B; Wickman, G

    1997-01-01

    The general collection efficiency has been measured in liquid isooctane (C8H18) and tetramethylsilane (Si(CH3)4) used as the sensitive media in a parallel-plate ionization chamber, with an electrode distance of 1 mm, intended for photon and electron dosimetry applications. The liquid ionization chamber was irradiated at different dose rates by 140 keV photons from the decay of radioactive 99mTc. The measurements were made at potential differences of 50, 100, 200 and 500 V. Measurements were performed for each liquid and electric field strength, with the decay rate of 99mTc used as the dose-rate reference. The maximum dose rate was about 150 mGy min-1 in each experiment. When the measured general collection efficiency values are compared with the theoretical predictions for collection efficiency in gases, it is found that the latter also describe the general collection efficiency in the two liquids within 1% of the saturation current for collection efficiencies down to 60% when using experimentally determined recombination rate constants and on mobilities characteristic of each of the liquids.

  16. A combined segmented anode gas ionization chamber and time-of-flight detector for heavy ion elastic recoil detection analysis

    NASA Astrophysics Data System (ADS)

    Ström, Petter; Petersson, Per; Rubel, Marek; Possnert, Göran

    2016-10-01

    A dedicated detector system for heavy ion elastic recoil detection analysis at the Tandem Laboratory of Uppsala University is presented. Benefits of combining a time-of-flight measurement with a segmented anode gas ionization chamber are demonstrated. The capability of ion species identification is improved with the present system, compared to that obtained when using a single solid state silicon detector for the full ion energy signal. The system enables separation of light elements, up to Neon, based on atomic number while signals from heavy elements such as molybdenum and tungsten are separated based on mass, to a sample depth on the order of 1 μm. The performance of the system is discussed and a selection of material analysis applications is given. Plasma-facing materials from fusion experiments, in particular metal mirrors, are used as a main example for the discussion. Marker experiments using nitrogen-15 or oxygen-18 are specific cases for which the described improved species separation and sensitivity are required. Resilience to radiation damage and significantly improved energy resolution for heavy elements at low energies are additional benefits of the gas ionization chamber over a solid state detector based system.

  17. Spin Pumping in Superfluid ^3He in High Magnetic Field

    NASA Astrophysics Data System (ADS)

    Kojima, H.; Suzuki, K.; Aoki, Y.; Yamaguchi, A.; Ishimoto, H.

    2008-03-01

    The spin flow dynamics in superfluid ^3He A1 phase in magnetic field has been studied up to 13 tesla. The apparatus consists of a large reservoir of of A1 phase in which a small enclosed chamber with a built-in differential pressure sensor is immersed. The chamber is connected to the reservoir via a superleak channel. The chamber is fabricated from Macor parts such that the residual heat leak is much reduced from those in our experiments. Our focus is on the measurement of relaxation of the induced pressure subsequent to either magnetically induced spin-polarized superflow or by electrostatic spin pumping. In general, both methods of measurement show that the relaxation time (τ) of the induced pressure tends to vanish smoothly as the transition temperature Tc2 is approached. However, the observed dependence of τ on magnetic field is different. The measured τ by the field gradient method continues to increase up to 8 tesla. On the other hand, τ measured by the spin pumping method tends to saturate to a constant between 5 and 13 tesla. The discrepancy is unexpected and not yet understood.

  18. Nuclear magnetic relaxation of3He gas. I. Pure3He

    NASA Astrophysics Data System (ADS)

    Lusher, C. P.; Secca, M. F.; Richards, M. G.

    1988-07-01

    Longitudinal relaxation times T 1 have been measured in3He gas, using pulsed NMR, for number densities between 3 × 1023 and 6 × 1025 spins m-3 and temperatures between 0.6 and 15 K. Relaxation takes place on or near the walls of the Pyrex sample cells and measurements of T 1 give information about the surface phases. A cryogenic wall coating of solid molecular hydrogen was found to delay the formation of a3He monolayer on cooling, and T 1 measurements were consistent with a binding energy of ˜13 K for a3He atom to a hydrogen surface. At temperatures below ˜2 K a completed3He monolayer forms on the H2 coating. No variation of the areal density of monolayer completion with bulk number density at fixed temperature could be observed and the completed3He monolayer is thought to be a dense fluid. Baking the Pyrex sample cells under vacuum and using an rf discharge in3He gas to clean the walls before sealing in the sample gas were found to increase the observed T1's by up to three orders of magnitude. Once a3He monolayer has formed on the H2 surface in these cleaned, sealed cells, the dipolar interaction between adsorbed spins is thought to be the dominant source of longitudinal relaxation. The data are consistent with a dipolar relaxation model with a correlation time of ˜2 × 10-9 sec. This time is long compared to the value of 10-11 or 10-12 sec in the 3D fluid. This suggests that if the surface phase is a 2D fluid and the dipolar mechanism is indeed the dominant one, then the atoms in the 2D fluid are less mobile than in three dimensions. This is consistent with recent susceptibility measurements.

  19. Correction of measured Gamma-Knife output factors for angular dependence of diode detectors and PinPoint ionization chamber.

    PubMed

    Hršak, Hrvoje; Majer, Marija; Grego, Timor; Bibić, Juraj; Heinrich, Zdravko

    2014-12-01

    Dosimetry for Gamma-Knife requires detectors with high spatial resolution and minimal angular dependence of response. Angular dependence and end effect time for p-type silicon detectors (PTW Diode P and Diode E) and PTW PinPoint ionization chamber were measured with Gamma-Knife beams. Weighted angular dependence correction factors were calculated for each detector. The Gamma-Knife output factors were corrected for angular dependence and end effect time. For Gamma-Knife beams angle range of 84°-54°. Diode P shows considerable angular dependence of 9% and 8% for the 18 mm and 14, 8, 4 mm collimator, respectively. For Diode E this dependence is about 4% for all collimators. PinPoint ionization chamber shows angular dependence of less than 3% for 18, 14 and 8 mm helmet and 10% for 4 mm collimator due to volumetric averaging effect in a small photon beam. Corrected output factors for 14 mm helmet are in very good agreement (within ±0.3%) with published data and values recommended by vendor (Elekta AB, Stockholm, Sweden). For the 8 mm collimator diodes are still in good agreement with recommended values (within ±0.6%), while PinPoint gives 3% less value. For the 4 mm helmet Diodes P and E show over-response of 2.8% and 1.8%, respectively. For PinPoint chamber output factor of 4 mm collimator is 25% lower than Elekta value which is generally not consequence of angular dependence, but of volumetric averaging effect and lack of lateral electronic equilibrium. Diodes P and E represent good choice for Gamma-Knife dosimetry.

  20. SU-D-19A-01: Can Farmer-Type Ionization Chambers Be Used to Improve the Accuracy of Low-Energy Electron Beam Reference Dosimetry?

    SciTech Connect

    Muir, B R; McEwen, M R

    2014-06-01

    Purpose: To investigate the use of cylindrical Farmer-type ionization chambers to improve the accuracy of low-energy electron beam calibration. Historically, these chamber types have not been used in beams with incident energies less than 10 MeV (R{sub 5} {sub 0} < 4.3 cm) because early investigations suggested large (up to 5 %) fluence perturbation factors in these beams, implying that a significant component of uncertainty would be introduced if used for calibration. More recently, the assumptions used to determine perturbation corrections for cylindrical chambers have been questioned. Methods: Measurements are made with cylindrical chambers in Elekta Precise 4, 8 and 18 MeV electron beams. Several chamber types are investigated that employ graphite walls and aluminum electrodes with very similar specifications (NE2571, NE2505/3, FC65-G). Depth-ionization scans are measured in water in the 8 and 18 MeV beams. To reduce uncertainty from chamber positioning, measurements in the 4 MeV beam are made at the reference depth in Virtual Water™. The variability of perturbation factors is quantified by comparing normalized response of various chambers. Results: Normalized ion chamber response varies by less than 0.7 % for similar chambers at average electron energies corresponding to that at the reference depth from 4 or 6 MeV beams. Similarly, normalized measurements made with similar chambers at the reference depth in the 4 MeV beam vary by less than 0.4 %. Absorbed dose calibration coefficients derived from these results are stable within 0.1 % on average over a period of 6 years. Conclusion: These results indicate that the uncertainty associated with differences in fluence perturbations for cylindrical chambers with similar specifications is only 0.2 %. The excellent long-term stability of these chambers in both photon and electron beams suggests that these chambers might offer the best performance for all reference dosimetry applications.

  1. {sup 3}He melting pressure thermometry

    SciTech Connect

    Ni, W.; Xia, J.S.; Adams, E.D.

    1995-10-01

    High-precision measurements of the {sup 3}He melting pressure versus temperature have been made from 500 {mu}K to 25 mK using a {sup 60}Co nuclear orientation primary thermometer and a Pt NMR susceptibility secondary thermometer. Temperatures for the fixed points on the melting curve are: the superfluid A transition T{sub A}=2.505 mK, the A-B transition T{sub AB}=1.948 mK, and the solid ordering temperature T{sub N}=0.934 mK. These fixed points and a functional form for P(T) constitute a convenient temperature scale, based on a primary thermometer, usable to well below 1 mK.

  2. A novel convolution-based approach to address ionization chamber volume averaging effect in model-based treatment planning systems

    NASA Astrophysics Data System (ADS)

    Barraclough, Brendan; Li, Jonathan G.; Lebron, Sharon; Fan, Qiyong; Liu, Chihray; Yan, Guanghua

    2015-08-01

    The ionization chamber volume averaging effect is a well-known issue without an elegant solution. The purpose of this study is to propose a novel convolution-based approach to address the volume averaging effect in model-based treatment planning systems (TPSs). Ionization chamber-measured beam profiles can be regarded as the convolution between the detector response function and the implicit real profiles. Existing approaches address the issue by trying to remove the volume averaging effect from the measurement. In contrast, our proposed method imports the measured profiles directly into the TPS and addresses the problem by reoptimizing pertinent parameters of the TPS beam model. In the iterative beam modeling process, the TPS-calculated beam profiles are convolved with the same detector response function. Beam model parameters responsible for the penumbra are optimized to drive the convolved profiles to match the measured profiles. Since the convolved and the measured profiles are subject to identical volume averaging effect, the calculated profiles match the real profiles when the optimization converges. The method was applied to reoptimize a CC13 beam model commissioned with profiles measured with a standard ionization chamber (Scanditronix Wellhofer, Bartlett, TN). The reoptimized beam model was validated by comparing the TPS-calculated profiles with diode-measured profiles. Its performance in intensity-modulated radiation therapy (IMRT) quality assurance (QA) for ten head-and-neck patients was compared with the CC13 beam model and a clinical beam model (manually optimized, clinically proven) using standard Gamma comparisons. The beam profiles calculated with the reoptimized beam model showed excellent agreement with diode measurement at all measured geometries. Performance of the reoptimized beam model was comparable with that of the clinical beam model in IMRT QA. The average passing rates using the reoptimized beam model increased substantially from 92.1% to

  3. Two-dimensional and quasi-three-dimensional dosimetry of hadron and photon beams with the Magic Cube and the Pixel Ionization Chamber.

    PubMed

    Cirio, R; Garelli, E; Schulte, R; Amerio, S; Boriano, A; Bourhaleb, F; Coutrakon, G; Donetti, M; Giordanengo, S; Koss, P; Madon, E; Marchetto, F; Nastasi, U; Peroni, C; Santuari, D; Sardo, A; Scielzo, G; Stasi, M; Trevisiol, E

    2004-08-21

    Two detectors for fast two-dimensional (2D) and quasi-three-dimensional (quasi-3D) verification of the dose delivered by radiotherapy beams have been developed at University and Istituto Nazionale di Fisica Nucleare (INFN) of Torino. The Magic Cube is a stack of strip-segmented ionization chambers interleaved with water-equivalent slabs. The parallel plate ionization chambers have a sensitive area of 24 x 24 cm2, and consist of 0.375 cm wide and 24 cm long strips. There are a total of 64 strips per chamber. The Magic Cube has been tested with the clinical proton beam at Loma Linda University Medical Centre (LLUMC), and was shown to be capable of fast and precise quasi-3D dose verification. The Pixel Ionization Chamber (PXC) is a detector with pixel anode segmentation. It is a 32 x 32 matrix of 1024 cylindrical ionization cells arranged in a square 24 x 24 cm2 area. Each cell has 0.4 cm diameter and 0.55 cm height, at a pitch of 0.75 cm separates the centre of adjacent cells. The sensitive volume of each single ionization cell is 0.07 cm3. The detectors are read out using custom designed front-end microelectronics and a personal computer-based data acquisition system. The PXC has been used to verify dynamic intensity-modulated radiotherapy for head-and-neck and breast cancers.

  4. Two-dimensional and quasi-three-dimensional dosimetry of hadron and photon beams with the Magic Cube and the Pixel Ionization Chamber

    NASA Astrophysics Data System (ADS)

    Cirio, R.; Garelli, E.; Schulte, R.; Amerio, S.; Boriano, A.; Bourhaleb, F.; Coutrakon, G.; Donetti, M.; Giordanengo, S.; Koss, P.; Madon, E.; Marchetto, F.; Nastasi, U.; Peroni, C.; Santuari, D.; Sardo, A.; Scielzo, G.; Stasi, M.; Trevisiol, E.

    2004-08-01

    Two detectors for fast two-dimensional (2D) and quasi-three-dimensional (quasi-3D) verification of the dose delivered by radiotherapy beams have been developed at University and Istituto Nazionale di Fisica Nucleare (INFN) of Torino. The Magic Cube is a stack of strip-segmented ionization chambers interleaved with water-equivalent slabs. The parallel plate ionization chambers have a sensitive area of 24 × 24 cm2, and consist of 0.375 cm wide and 24 cm long strips. There are a total of 64 strips per chamber. The Magic Cube has been tested with the clinical proton beam at Loma Linda University Medical Centre (LLUMC), and was shown to be capable of fast and precise quasi-3D dose verification. The Pixel Ionization Chamber (PXC) is a detector with pixel anode segmentation. It is a 32 × 32 matrix of 1024 cylindrical ionization cells arranged in a square 24 × 24 cm2 area. Each cell has 0.4 cm diameter and 0.55 cm height, at a pitch of 0.75 cm separates the centre of adjacent cells. The sensitive volume of each single ionization cell is 0.07 cm3. The detectors are read out using custom designed front-end microelectronics and a personal computer-based data acquisition system. The PXC has been used to verify dynamic intensity-modulated radiotherapy for head-and-neck and breast cancers.

  5. A pixel ionization chamber used as beam monitor at the Institut Curie—Centre de Protontherapie de Orsay (CPO)

    NASA Astrophysics Data System (ADS)

    La Rosa, A.; Garella, M. A.; Bourhaleb, F.; Cirio, R.; Donetti, M.; Giordanengo, S.; Givehchi, N.; Marchetto, F.; Martin, F.; Meyroneinc, S.; Peroni, C.; Pittà, G.

    2006-09-01

    The Dipartimento di Fisica Sperimentale and the Istituto Nazionale di Fisica Nucleare (INFN), Torino, in collaboration with the Institut Curie—Centre de Protontherapie de Orsay (CPO), have developed and built a pixel parallel plate ionization chamber to be used as monitor for the proton therapy beam line at the Institut Curie—CPO (Orsay, France). The sensitive area of the detector is (160×160) mm 2, with the anode segmented in 1024 square pixels arranged in a 32×32 matrix; the area of each pixel is (5×5) mm 2. The detector has been placed on the beam line just upstream of the last collimator to monitor the beam shape and to measure the stability and reproducibility of the delivery system. In this paper, we present a detailed description of the detector and the results of a set of preliminary tests.

  6. Simulation of the Mg(Ar) ionization chamber currents by different Monte Carlo codes in benchmark gamma fields

    NASA Astrophysics Data System (ADS)

    Lin, Yi-Chun; Liu, Yuan-Hao; Nievaart, Sander; Chen, Yen-Fu; Wu, Shu-Wei; Chou, Wen-Tsae; Jiang, Shiang-Huei

    2011-10-01

    High energy photon (over 10 MeV) and neutron beams adopted in radiobiology and radiotherapy always produce mixed neutron/gamma-ray fields. The Mg(Ar) ionization chambers are commonly applied to determine the gamma-ray dose because of its neutron insensitive characteristic. Nowadays, many perturbation corrections for accurate dose estimation and lots of treatment planning systems are based on Monte Carlo technique. The Monte Carlo codes EGSnrc, FLUKA, GEANT4, MCNP5, and MCNPX were used to evaluate energy dependent response functions of the Exradin M2 Mg(Ar) ionization chamber to a parallel photon beam with mono-energies from 20 keV to 20 MeV. For the sake of validation, measurements were carefully performed in well-defined (a) primary M-100 X-ray calibration field, (b) primary 60Co calibration beam, (c) 6-MV, and (d) 10-MV therapeutic beams in hospital. At energy region below 100 keV, MCNP5 and MCNPX both had lower responses than other codes. For energies above 1 MeV, the MCNP ITS-mode greatly resembled other three codes and the differences were within 5%. Comparing to the measured currents, MCNP5 and MCNPX using ITS-mode had perfect agreement with the 60Co, and 10-MV beams. But at X-ray energy region, the derivations reached 17%. This work shows us a better insight into the performance of different Monte Carlo codes in photon-electron transport calculation. Regarding the application of the mixed field dosimetry like BNCT, MCNP with ITS-mode is recognized as the most suitable tool by this work.

  7. Elastic Compton Scattering from 3He

    NASA Astrophysics Data System (ADS)

    Margaryan, Arman; Griesshammer, Harald W.; Phillips, Daniel R.; Strandberg, Bruno; McGovern, Judith A.; Shukla, Deepshikha

    2017-01-01

    We study elastic Compton scattering on 3He using chiral effective field theory (χEFT) at photon energies from 60 MeV to approximately 120 MeV. Experiments to measure this process have been proposed for both MAMI at Mainz and the HI γS facility at TUNL. I will present the revised results of a full calculation at third order in the expansion (O (Q3)). The amplitude involves a sum of both one- and two-nucleon Compton-scattering mechanisms. We have recently computed the fourth-order two-nucleon diagrams. The numerical impact they have on the cross-section results will be discussed. I will also present results in which amplitudes used so far are augmented by the leading effects from Δ (1232) degrees of freedom, a step which has already been performed for the proton and deuteron processes. Both cross sections and doubly-polarized asymmetries will be presented, and the sensitivity of these observables to the values of neutron scalar and spin polarizabilities will be assessed. This material is based upon work supported in part by DOE and George Washington University.

  8. Characterization and performances of a monitoring ionization chamber dedicated to IBA-universal irradiation head for Pencil Beam Scanning

    NASA Astrophysics Data System (ADS)

    Courtois, C.; Boissonnat, G.; Brusasco, C.; Colin, J.; Cussol, D.; Fontbonne, J. M.; Marchand, B.; Mertens, T.; de Neuter, S.; Peronnel, J.

    2014-02-01

    Every radiotherapy center has to be equipped with real-time beam monitoring devices. In 2008, we developed an ionization chamber in collaboration with the IBA (Ion Beam Applications) company. This monitoring device called IC2/3 was developed to be used in IBA universal irradiation head for Pencil Beam Scanning (PBS). Here we present the characterization of the IC2/3 monitor in the energy and flux ranges used in protontherapy. The equipment has been tested with an IBA cyclotron able to deliver proton beams from 70 to 230 MeV. This beam monitoring device has been validated and is now installed at the Westdeutsches Protonentherapiezentrum Essen protontherapy center (WPE, Germany). The results obtained in both terms of spatial resolution and dose measurements are at least equal to the initial specifications needed for PBS purposes. The detector measures the dose with a relative uncertainty lower than 1% in the range from 0.5 Gy/min to 8 Gy/min while the spatial resolution is better than 250 μm. The technology has been patented and five IC2/3 chambers were delivered to IBA. Nowadays, IBA produces the IC2/3 beam monitoring device as a part of its Proteus 235 product.

  9. sup 3 He- sup 3 He dating: A case for mixing of young and old groundwaters

    SciTech Connect

    Kamensky, I.L.; Tolstikhin, I.N. ); Tokarev, I.V. )

    1991-10-01

    {sup 3}He/{sup 4}He and {sup 20}Ne/{sup 4}He ratios were measured in shallow underground waters (opened by water-supplying wells) of the Large Vud-Javr intramountain artesian basin in the Khibiny alkaline massif, the Kola Peninsula. The ratios vary from 1.321 {times} 10{sup {minus}6} to 2.065 {times} 10{sup {minus}6} and from 1.412 to 2.941, respectively, and a well-defined correlation is observed between them. Both these ratios in aquifers are known to be time-dependent, the former increases with time due to accumulation of {sup 3}He, produced in waters by {sup 3}H {beta}-decay; the latter decreases due to migration of helium from water-bearing rocks into the waters. The correlation is interpreted as a result of the mixing of two different types of waters. The approximation line enables the authors to estimate the isotopic ratios for the endmembers participating in the mixing and the mean residence time ({tau}) of tritigenic helium-3 in the water: (1) {sup 3}He/{sup 4}He = 3.655 {times} 10{sup {minus}6}, {sup 20}Ne/{sup 4}He = 4.03, and taking into consideration {sup 3}H concentrations in the well waters, {sup 3}H = 31.1 TU (practically the same for all samples), {tau} = 15.8 {plus minus} 1.5 years for the young water; (2) {sup 3}He/{sup 4}He = 0.20 {times} 10{sup {minus}6}, {sup 20}Ne/{sup 4}He = 0.18 and T = 0.11 Ma for the old one, the contribution of the old water being less than 10%. In one well a considerable contribution of modern-day meteoric water, about 16%, is observed.

  10. Laser Induced Fluorescence Spectroscopy of Neutral and Ionized Polycyclic Aromatic Hydrocarbons in the Cosmic Simulation Chamber

    NASA Technical Reports Server (NTRS)

    Bejaoui, Salma; Salama, Farid; Contreras, Cesar; Sciamma O'Brien, Ella; Foing, Bernard; Pascale, Ehrenfreund

    2015-01-01

    Polycyclic aromatic hydrocarbon (PAH) molecules are considered the best carriers to account for the ubiquitous infrared emission bands. PAHs have also been proposed as candidates to explain the diffuse interstellar bands (DIBs), a series of absorption features seen on the interstellar extinction curve and are plausible carriers for the extended red emission (ERE), a photoluminescent process associated with a wide variety of interstellar environments. Extensive efforts have been devoted over the past two decades to characterize the physical and chemical properties of PAH molecules and ions in space. Absorption spectra of PAH molecules and ions trapped in solid matrices have been compared to the DIBs. Absorption spectra of several cold, isolated gas-phase PAHs have also been measured under experimental conditions that mimic the interstellar conditions. The purpose of this study is to provide a new dimension to the existing spectroscopic database of neutral and single ionized PAHs that is largely based on absorption spectra by adding emission spectroscopy data. The measurements are based on the laser induced fluorescence (LIF) technique and are performed with the Pulsed Discharge Nozzle (PDN) of the COSmIC laboratory facility at NASA Ames laboratory. The PDN generates a plasma in a free supersonic jet expansion to simulate the physical and the chemical conditions in interstellar environments. We focus, here, on the fluorescence spectra of large neutral PAHs and their cations where there is a lack of fluorescence spectroscopy data. The astronomical implications of the data (e.g., ERE) are examined.

  11. Laser Induced Fluorescence Spectroscopy of Neutral and Ionized Polycyclic Aromatic Hydrocarbons in a Cosmic Simulation Chamber

    NASA Astrophysics Data System (ADS)

    Bejaoui, Salma; Salama, Farid

    2015-08-01

    Polycyclic aromatic hydrocarbon (PAH) molecules are considered the best carriers to account for the ubiquitous infrared emission bands. PAHs have also been proposed as candidates to explain the diffuse interstellar bands (DIBs), a series of absorption features seen on the interstellar extinction curve and are plausible carriers for the extended red emission (ERE), a photoluminescent process associated with a wide variety of interstellar environments. Extensive efforts have been devoted over the past two decades to characterize the physical and chemical properties of PAH molecules and ions in space. Absorption spectra of PAH molecules and ions trapped in solid matrices have been compared to the DIBs [1, 2]. Absorption spectra of several cold, isolated gas-phase PAHs have also been measured under experimental conditions that mimic the interstellar conditions [see 3 for a review]. The purpose of this study is to provide a new dimension to the existing spectroscopic database of neutral and single ionized PAHs that is largely based on absorption spectra by adding emission spectroscopy data. The measurements are based on the laser-induced fluorescence (LIF) technique [4] and are performed with the Pulsed Discharge Nozzle (PDN) of the COSmIC laboratory facility at NASA Ames laboratory. The PDN generates plasma in a free supersonic jet expansion to simulate the physical and the chemical conditions in interstellar environments. We focus, here, on the fluorescence spectra of large neutral PAHs and their cations where there is a lack of fluorescence spectroscopy data. The astronomical implications of the data (e.g., ERE) are examinedReferences[1] F. Salama, E. Bakes, L.J. Allamandola, A.G.G.M. Tielens, Astrophys. J., 458 (1996) p.621[2] F. Salama, The ISO Revolution, EDP Sciences, Les Ulis, France (1999) p.65[3] Salama F., In Organic Matter in Space, IAU Symposium 251, Kwok & Sandford Eds.Cambridge University Press,4, S251,(2008), p. 357 (2008) and references therein.[4

  12. Studies of 3He+3He, T+3He, and p +D nuclear reactions relevant to stellar or Big-Bang Nucleosynthesis using ICF plasmas at OMEGA

    NASA Astrophysics Data System (ADS)

    Zylstra, Alex; Gatu Johnson, Maria; Frenje, Johan; Li, Chikang; Seguin, Fredrick; Sio, Hong; Rosenberg, Michael; Rinderknecht, Hans; Petrasso, Richard; Herrmann, Hans; Kim, Yong Ho; Hale, Gerry; McNabb, Dennis; Sayre, Dan; Pino, Jesse; Brune, Carl; Bacher, Andy; Forrest, Chad; Glebov, Vladimir; Stoeckl, Christian; Janezic, Roger; Sangster, Craig

    2014-10-01

    The 3He+3He, T+3He, and p +D reactions directly relevant to Stellar or Big-Bang Nucleosynthesis (BBN) have been studied at the OMEGA laser facility using high-temperature low-density `exploding pusher' implosions. The advantage of using these plasmas is that they better mimic astrophysical systems than cold-target accelerator experiments. Measured proton spectra from the 3He3He reaction are used to constrain nuclear R-matrix modeling. The resulting T+3He γ-ray data rule out an anomalously-high 6Li production during BBN as an explanation to the high observed values in primordial material. The proton spectrum from the T+3He reaction is also being used to constrain the R-matrix model. Recent experiments have probed the p +D reaction for the first time in a plasma; this reaction is relevant to energy production in protostars, brown dwarfs and at higher CM energies to BBN. This work was partially supported by the US DOE, NLUF, LLE, and GA.

  13. A two-dimensional liquid-filled ionization chamber array prototype for small-field verification: characterization and first clinical tests

    NASA Astrophysics Data System (ADS)

    Brualla-González, Luis; Gómez, Faustino; Vicedo, Aurora; González-Castaño, Diego M.; Gago-Arias, Araceli; Pazos, Antonio; Zapata, Martín; Roselló, Joan V.; Pardo-Montero, Juan

    2012-08-01

    In this work we present the design, characterization and first clinical tests of an in-house developed two-dimensional liquid-filled ionization chamber prototype for the verification of small radiotherapy fields and treatments containing such small fields as in radiosurgery, which consists of 2 mm × 2 mm pixels arranged on a 16×8 rectangular grid. The ionization medium is isooctane. The characterization of the device included the study of depth, field-size and dose-rate dependences, which are sufficiently moderate for a good operation at therapy radiation levels. However, the detector presents an important anisotropic response, up to ≃ 12% for front versus near-lateral incidence, which can impact the verification of full treatments with different incidences. In such a case, an anisotropy correction factor can be applied. Output factors of small square fields measured with the device show a small systematic over-response, less than 1%, when compared to unshielded diode measurements. An IMRT radiosurgery treatment has been acquired with the liquid-filled ionization chamber device and compared with film dosimetry by using the gamma method, showing good agreement: over 99% passing rates for 1.2% and 1.2 mm for an incidence-per-incidence analysis; 100% passing rates for tolerances 1.8% and 1.8 mm when the whole treatment is analysed and the anisotropy correction factor is applied. The point dose verification for each incidence of the treatment performed with the liquid-filled ionization chamber agrees within 1% with a CC01 ionization chamber. This prototype has shown the utility of this kind of technology for the verification of small fields/treatments. Currently, a larger device covering a 5 cm × 5 cm area is under development.

  14. On the interpretation of current-voltage curves in ionization chambers using the exact solution of the Thomson problem

    NASA Astrophysics Data System (ADS)

    Ridenti, M. A.; Pascholati, P. R.; Gonçalves, J. A. C.; Bueno, C. C.

    2015-09-01

    The I - ΔV characteristic curve of a well type ionization chamber irradiated with 192Ir sources (0.75 Ci-120 Ci) was fitted using the exact solution of the Thomson problem. The recombination coefficient and saturation current were estimated using this new approach. The saturation current was compared with the results of the conventional method based on Boag-Wilson formula. It was verified that differences larger than 1% between both methods only occurred at activities higher than 55 Ci. We concluded that this new approach is recommended for a more accurate estimate of the saturation current when it is not possible to measure currents satisfying the condition I /Isat > 0.95. From the calibration curve the average value of pairs of carriers created per unit volume was estimated to be equal to η = 8.1 ×10-3cm-3s-1 Bq-1 and from that value it was estimated that ~ 17 pairs were created on average per second for each decay of the source.

  15. Recycling of 3He from lung magnetic resonance imaging.

    PubMed

    Salhi, Z; Grossmann, T; Gueldner, M; Heil, W; Karpuk, S; Otten, E W; Rudersdorf, D; Surkau, R; Wolf, U

    2012-06-01

    We have developed the means to recycle (3) He exhaled by patients after imaging the lungs using magnetic resonance of hyperpolarized (3) He. The exhaled gas is collected in a helium leak proof bag and further compressed into a steel bottle. The collected gas contains about 1-2% of (3) He, depending on the amount administered and the number of breaths collected to wash out the (3) He gas from the lungs. (3) He is separated from the exhaled air using zeolite molecular sieve adsorbent at 77 K followed by a cold head at 8 K. Residual gaseous impurities are finally absorbed by a commercial nonevaporative getter. The recycled (3) He gas features high purity, which is required for repolarization by metastability exchange optical pumping. At present, we achieve a collection efficiency of 80-84% for exhaled gas from healthy volunteers and cryogenic separation efficiency of 95%.

  16. Performance Limits of Pulse Tube Cryocoolers Using 3HE

    NASA Astrophysics Data System (ADS)

    Kittel, P.

    2008-03-01

    The enthalpy, entropy, and exergy flows resulting from the real gas effects of 3He in ideal pulse tube cryocoolers are described. The discussion follows a previous description of the real gas effects of 4He in ideal pulse tube cryocoolers and makes use of a recently developed model of the thermophysical properties of 3He. This model is used to describe how the thermodynamic flows are affected by real gas phenomena of 3He and compares these effects to similar effects for 4He. The analysis was done over the pressure range 0.3-2 MPa and temperatures down to 1 K. At 2 MPa there is almost no difference in the cooling power between 3He and 4He. At lower pressures, using 3He is advantageous. There is a 1-2 K reduction in the 3He cooling power vs. temperature curves compared to those for 4He in the 0.3-1 MPa range.

  17. /sup 3/He functions in tokamak-pumped laser systems

    SciTech Connect

    Jassby, D.L.

    1986-10-01

    /sup 3/He placed in an annular cell around a tokamak fusion generator can convert moderated fusion neutrons to energetic ions by the /sup 3/He(n,p)T reaction, and thereby excite gaseous lasants mixed with the /sup 3/He while simultaneously breeding tritium. The total /sup 3/He inventory is about 4 kg for large tokamak devices. Special configurations of toroidal-field magnets, neutron moderators and beryllium reflectors are required to permit nearly uniform neutron current into the laser cell with minimal attenuation. The annular laser radiation can be combined into a single output beam at the top of the tokamak.

  18. Comparison of depth-dose distributions of proton therapeutic beams calculated by means of logical detectors and ionization chamber modeled in Monte Carlo codes

    NASA Astrophysics Data System (ADS)

    Pietrzak, Robert; Konefał, Adam; Sokół, Maria; Orlef, Andrzej

    2016-08-01

    The success of proton therapy depends strongly on the precision of treatment planning. Dose distribution in biological tissue may be obtained from Monte Carlo simulations using various scientific codes making it possible to perform very accurate calculations. However, there are many factors affecting the accuracy of modeling. One of them is a structure of objects called bins registering a dose. In this work the influence of bin structure on the dose distributions was examined. The MCNPX code calculations of Bragg curve for the 60 MeV proton beam were done in two ways: using simple logical detectors being the volumes determined in water, and using a precise model of ionization chamber used in clinical dosimetry. The results of the simulations were verified experimentally in the water phantom with Marcus ionization chamber. The average local dose difference between the measured relative doses in the water phantom and those calculated by means of the logical detectors was 1.4% at first 25 mm, whereas in the full depth range this difference was 1.6% for the maximum uncertainty in the calculations less than 2.4% and for the maximum measuring error of 1%. In case of the relative doses calculated with the use of the ionization chamber model this average difference was somewhat greater, being 2.3% at depths up to 25 mm and 2.4% in the full range of depths for the maximum uncertainty in the calculations of 3%. In the dose calculations the ionization chamber model does not offer any additional advantages over the logical detectors. The results provided by both models are similar and in good agreement with the measurements, however, the logical detector approach is a more time-effective method.

  19. Large area neutron detector based on Li6 ionization chamber with integrated body-moderator of high density polyethylene

    SciTech Connect

    Ianakiev, Kiril D.; Swinhoe, Martyn T.; Chung, Kiwhan; Makela, Mark F.

    2009-06-30

    A detector was developed and funded by DHS to be a lower cost alternative to 3He detectors. A 6Li foil-lined ionization chamber was prepared with fill gas at one atmosphere and pulse mode operation. The high-density polyethylene (HOPE) body serves also as a neutron moderator. All electrodes, including high voltage bias supply, are hermetically sealed within the plastic slabs.

  20. Early Days of Superfluid ^3He: An Experimenter's View

    NASA Astrophysics Data System (ADS)

    Lee, David

    2010-03-01

    The formulation of the BCS theory led theorists to investigate possible non-S-wave pairing in liquid ^3He. Unfortunately as time went on, estimates for the pairing temperature became unattainably low. Nevertheless, the push to lower temperatures by experimentalists continued and was facilitated by the invention of the dilution refrigerator. Nuclear adiabatic demagnetization could then be used to cool liquid ^3He to ˜1 mK as demonstrated by Goodkind. An alternate approach, suggested by Pomeranchuk, involved adiabatic compression of liquid ^3He into the solid phase. Efforts to develop this technique at the Kapitza Institute, La Jolla and Cornell achieved success in demonstrating cooling of mixtures of liquid and solid ^3He to ˜ 1 mK following dilution refrigerator pre-cooling. Although there was great pessimism regarding the possible observation of pairing in liquid ^3He, the unsettled problem of magnetic ordering in solid ^3He beckoned. Ultimately two phase transition along the melting curve were observed by Osheroff et al at Cornell. Although first associated with solid ^3He, extensive NMR studies showed them to be two new phases of liquid ^3He. A brief history of experiments at various laboratories following the discovery is given, along with early interpretations given by Anderson and Morel and Balian and Werthamer. The key role of Leggett's spin dynamics is also discussed.

  1. Measurement of absorbed dose-to-water for an HDR {sup 192}Ir source with ionization chambers in a sandwich setup

    SciTech Connect

    Araki, Fujio; Kouno, Tomohiro; Ohno, Takeshi; Kakei, Kiyotaka; Yoshiyama, Fumiaki; Kawamura, Shinji

    2013-09-15

    Purpose: In this study, a dedicated device for ion chamber measurements of absorbed dose-to-water for a Nucletron microSelectron-v2 HDR {sup 192}Ir brachytherapy source is presented. The device uses two ionization chambers in a so-called sandwich assembly. Using this setup and by taking the average reading of the two chambers, any dose error due to difficulties in absolute positioning (centering) of the source in between the chambers is cancelled to first order. The method's accuracy was examined by comparing measurements with absorbed dose-to-water determination based on the AAPM TG-43 protocol.Methods: The optimal source-to-chamber distance (SCD) for {sup 192}Ir dosimetry was determined from ion chamber measurements in a water phantom. The {sup 192}Ir source was sandwiched between two Exradin A1SL chambers (0.057 cm{sup 3}) at the optimal SCD separation. The measured ionization was converted to the absorbed dose-to-water using a {sup 60}Co calibration factor and a Monte Carlo-calculated beam quality conversion factor, k{sub Q}, for {sup 60}Co to {sup 192}Ir. An uncertainty estimate of the proposed method was determined based on reproducibility of measurements at different institutions for the same type of source.Results: The optimal distance for the A1SL chamber measurements was determined to be 5 cm from the {sup 192}Ir source center, considering the depth dependency of k{sub Q} for {sup 60}Co to {sup 192}Ir and the chamber positioning. The absorbed dose to water measured at (5 cm, 90°) on the transverse axis was 1.3% lower than TG-43 values and its reproducibility and overall uncertainty were 0.8% and 1.7%, respectively. The measurement doses at anisotropic points agreed within 1.5% with TG-43 values.Conclusions: The ion chamber measurement of absorbed dose-to-water with a sandwich method for the {sup 192}Ir source provides a more accurate, direct, and reference dose compared to the dose-to-water determination based on air-kerma strength in the TG-43 protocol

  2. SU-E-T-561: Development of Depth Dose Measurement Technique Using the Multilayer Ionization Chamber for Spot Scanning Method

    SciTech Connect

    Takayanagi, T; Fujitaka, S; Umezawa, M; Ito, Y; Nakashima, C; Matsuda, K

    2014-06-01

    Purpose: To develop a measurement technique which suppresses the difference between profiles obtained with a multilayer ionization chamber (MLIC) and with a water phantom. Methods: The developed technique multiplies the raw MLIC data by a correction factor that depends on the initial beam range and water equivalent depth. The correction factor is derived based on a Bragg curve calculation formula considering range straggling and fluence loss caused by nuclear reactions. Furthermore, the correction factor is adjusted based on several integrated depth doses measured with a water phantom and the MLIC. The measured depth dose profiles along the central axis of the proton field with a nominal field size of 10 by 10 cm were compared between the MLIC using the new technique and the water phantom. The spread out Bragg peak was 20 cm for fields with a range of 30.6 cm and 6.9 cm. Raw MLIC data were obtained with each energy layer, and integrated after multiplying by the correction factor. The measurements were performed by a spot scanning nozzle at Nagoya Proton Therapy Center, Japan. Results: The profile measured with the MLIC using the new technique is consistent with that of the water phantom. Moreover, 97% of the points passed the 1% dose /1mm distance agreement criterion of the gamma index. Conclusion: We have demonstrated that the new technique suppresses the difference between profiles obtained with the MLIC and with the water phantom. It was concluded that this technique is useful for depth dose measurement in proton spot scanning method.

  3. SU-D-213-04: Accounting for Volume Averaging and Material Composition Effects in An Ionization Chamber Array for Patient Specific QA

    SciTech Connect

    Fugal, M; McDonald, D; Jacqmin, D; Koch, N; Ellis, A; Peng, J; Ashenafi, M; Vanek, K

    2015-06-15

    Purpose: This study explores novel methods to address two significant challenges affecting measurement of patient-specific quality assurance (QA) with IBA’s Matrixx Evolution™ ionization chamber array. First, dose calculation algorithms often struggle to accurately determine dose to the chamber array due to CT artifact and algorithm limitations. Second, finite chamber size and volume averaging effects cause additional deviation from the calculated dose. Methods: QA measurements were taken with the Matrixx positioned on the treatment table in a solid-water Multi-Cube™ phantom. To reduce the effect of CT artifact, the Matrixx CT image set was masked with appropriate materials and densities. Individual ionization chambers were masked as air, while the high-z electronic backplane and remaining solid-water material were masked as aluminum and water, respectively. Dose calculation was done using Varian’s Acuros XB™ (V11) algorithm, which is capable of predicting dose more accurately in non-biologic materials due to its consideration of each material’s atomic properties. Finally, the exported TPS dose was processed using an in-house algorithm (MATLAB) to assign the volume averaged TPS dose to each element of a corresponding 2-D matrix. This matrix was used for comparison with the measured dose. Square fields at regularly-spaced gantry angles, as well as selected patient plans were analyzed. Results: Analyzed plans showed improved agreement, with the average gamma passing rate increasing from 94 to 98%. Correction factors necessary for chamber angular dependence were reduced by 67% compared to factors measured previously, indicating that previously measured factors corrected for dose calculation errors in addition to true chamber angular dependence. Conclusion: By comparing volume averaged dose, calculated with a capable dose engine, on a phantom masked with correct materials and densities, QA results obtained with the Matrixx Evolution™ can be significantly

  4. Solar Source Regions of Energetic 3He Emission

    NASA Astrophysics Data System (ADS)

    Mason, G. M.; Nitta, N. V.; Cohen, C. M.; Wiedenbeck, M. E.

    2012-12-01

    One of the surprising observations from the ACE mission has been the detection of energetic 3He emission occurring over multi-day periods. Previously observations of solar energetic 3He had detected short-lived "impulsive" energetic particle events which were associated with type III bursts and energetic electrons. The ACE observations were able to detect 3He at very low levels (<1% of 4He compared to ~10% in most earlier work) and this showed that the impulsive events often occurred during seemingly continuous multi-day periods of 3He emission. During solar active periods, 3He was present at 1 AU the majority of the time, giving evidence for either semi-continuous processes or else unresolved multiple small injections. The obvious injections during such periods were strongly associated with jet activity By adding STEREO and SDO observations we are seeking to extend the observational picture for these events. First, by following single 3He emitting regions from STEREO-B to ACE to STEREO-A we seek to examine for how long the 3He emission can continue, since any single spacecraft can be magnetically connected to a single region for only a few days and ACE often sees emission periods of that length. Second, by using SDO-AIA we seek to probe further the properties of the emitting regions to see if the previously reported association with jets is seen in events which we can now observe with greater resolution, sensitivity, and cadence than previously possible.

  5. ^3He neutron spin filters for polarized neutron scattering.

    NASA Astrophysics Data System (ADS)

    Chen, Wangchun; Borchers, Julie; Chen, Ying; O'Donovan, Kevin; Erwin, Ross; Lynn, Jeffrey; Majkrzak, Charles; McKenney, Sarah; Gentile, Thomas

    2006-03-01

    Polarized neutron scattering (PNS) is a powerful tool that probes the magnetic structures in a wide variety of magnetic materials. Polarized ^3He gas, produced by optical pumping, can be used to polarize or analyze neutron beams because of the strong spin dependence of the neutron absorption cross section for ^3He. Polarized ^3He neutron spin filters (NSF) have been of great interest in PNS community due to recent significant improvement of their performance. Here I will discuss successful applications using ^3He NSFs in polarized neutron reflectometry (PNR) and triple-axis spectrometry (TAS). In PNR, a ^3He NSF in conjunction with a position-sensitive detector allows for efficient polarization analysis of off-specular scattering over a broad range of reciprocal space. In TAS, a ^3He NSF in combination with a double focusing pyrolytic graphite monochromator provides greater versatility and higher intensity compared to a Heusler polarizer. Finally I will present the results from patterned magnetically-coupled thin films in PNR and our first ``proof-of-principle'' experiment in TAS, both of which were performed using ^3He NSF(s) at the NIST Center for Neutron Research.

  6. Neutron Detection Alternatives to 3He for National Security Applications

    SciTech Connect

    Kouzes, Richard T.; Ely, James H.; Erikson, Luke E.; Kernan, Warnick J.; Lintereur, Azaree T.; Siciliano, Edward R.; Stephens, Daniel L.; Stromswold, David C.; Van Ginhoven, Renee M.; Woodring, Mitchell L.

    2010-11-21

    One of the main uses for 3He is in gas proportional counters for neutron detection. Large radiation detection systems deployed for homeland security and proliferation detection applications use such systems. Due to the large increase in use of 3He for homeland security and basic research, the supply has dwindled, and can no longer meet the demand. This has led to the search for an alternative technology to replace the use of 3He-based neutron detectors. In this paper, we review the testing of currently commercially available alternative technologies for neutron detection in large systems used in various national security applications.

  7. Recent Advances of Polarized 3He Target at Jefferson Lab

    SciTech Connect

    Yi Qiang

    2011-10-01

    Polarized {sup 3}He target has been widely used in nuclear and particle experiments to study the neutron structure in the spin degree of freedom, as most of the {sup 3}He spin is carried by the unpaired neutron. Spin-Exchange Optical Pumping (SEOP) process is used in Jefferson Lab Hall A to polarize its {sup 3}He target. Through developments in recent years, both the performance and corresponding polarimetry of such a target were greatly improved. Several experiments recently carried out in Hall A benefited remarkably from this target for the record highest figure of merit.

  8. Experiments on polarization-dependent transport in 3He systems

    NASA Astrophysics Data System (ADS)

    Candela, D.; McAllaster, D. R.; Wei, L.-J.; Kalechofsy, N.

    1994-03-01

    Spin and momentum transport experiments are described for very dilute 3He- 4He mixtures and pure 3He brute-force polarized by a static field. Spin diffusion and rotation were observed in very dilute mixtures using a spin-wave resonance technique, and the viscosity increase due to polarization was observed using a vibrating wire. The mixture results are all well fit by the recent kinetic-equation calculations of Mullin and Jeon. Spin echoes were used to study transverse spin diffusion in pure 3He, providing the first clear evidence for polarization-induced relaxation-time anisotropy in a degenerate Fermi liquid.

  9. Long-term stability of liquid ionization chambers with regard to their qualification as local reference dosimeters for low dose-rate absorbed dose measurements in water.

    PubMed

    Bahar-Gogani, J; Grindborg, J E; Johansson, B E; Wickman, G

    2001-03-01

    The long-term sensitivity and calibration stability of liquid ionization chambers (LICs) has been studied at a local and a secondary standards dosimetry laboratory over a period of 3 years. The chambers were transported several times by mail between the two laboratories for measurements. The LICs used in this work are designed for absorbed dose measurements in the dose rate region of 0.1-100 mGy min(-1) and have a liquid layer thickness of 1 mm and a sensitive volume of 16.2 mm3. The liquids used as sensitive media in the chambers are mixtures of isooctane (C8H18) and tetramethylsilane (Si(CH3)4) in different proportions (about 2 to 1). Operating at a polarizing voltage of 300 V the leakage current of the chambers was stable and never exceeded 3% of the observable current at a dose rate of about 1 mGy min(-1). The volume sensitivity of the chambers was measured to be of the order of 10(-9) C Gy(-1) mm3. No systematic changes in the absorbed dose to water calibration was observed for any of the chambers during the test period (sigma < 0.2%). Variations in chamber dose response with small changes in the polarizing voltage as well as sensitivity changes with accumulated absorbed dose were also investigated. Measurements showed that the LIC response varies by 0.15% per 1% change in applied voltage around 300 V. No significant change could be observed in the LIC sensitivity after a single absorbed dose of 15 kGy. The results indicate that the LIC can be made to serve as a calibration transfer instrument and a reference detector for absorbed dose to water determinations providing good precision and long-term reproducibility.

  10. SU-E-T-645: Qualification of a 2D Ionization Chamber Array for Beam Steering and Profile Measurement

    SciTech Connect

    Gao, S; Balter, P; Rose, M; Simon, W

    2015-06-15

    Purpose: Establish a procedure for beam steering and profile measurement using a 2D ionization chamber array and show equivalence to a water scanning system. Methods: Multiple photon beams (30×30cm{sup 2} field) and electron beams (25×25cm{sup 2} cone) were steered in the radial and transverse directions using Sun Nuclear’s IC PROFILER (ICP). Solid water was added during steering to ensure measurements were beyond the buildup region. With steering complete, servos were zeroed and enabled. Photon profiles were collected in a 30×30cm{sup 2} field at dmax and 2.9 cm depth for flattened and FFF beams respectively. Electron profiles were collected with a 25×25cm{sup 2} cone and effective depth (solid water + 0.9 cm intrinsic buildup) as follows: 0.9 cm (6e), 1.9 cm (9e), 2.9 cm (12e, 16e, 20e). Profiles of the same energy, field size and depth were measured in water with Sun Nuclear’s 3D SCANNER (3DS). Profiles were re-measured using the ICP after the in-water scans. Profiles measured using the ICP and 3DS were compared by (a) examining the differences in Varian’s “Point Difference Symmetry” metric, (b) visual inspection of the overlaid profile shapes and (c) calculation of point-by-point differences. Results: Comparing ICP measurements before and after water scanning showed very good agreement indicating good stability of the linac and measurement system. Comparing ICP Measurements to water phantom measurements using Varian’s symmetry metric showed agreement within 0.5% for all beams. The average magnitude of the agreement was within 0.2%. Comparing ICP Measurements to water phantom measurements using point-by-point difference showed agreement within 0.5% inside of 80% area of the field width. Conclusion: Profile agreement to within 0.5% was observed between ICP and 3DS after steering multiple energies with the ICP. This indicates that the ICP may be used for steering electron beams, and both flattened and FFF photon beams. Song Gao: Sun Nuclear

  11. SU-E-T-460: Impact of the LINAC Repetition Rate On a High-Resolution Liquid Ionization Chamber Array for Patient-Specific QA

    SciTech Connect

    Wang, S; Driewer, J; Zheng, D; Lei, Y; Zhang, Q; Zhu, X; Li, S; Enke, C; Zhou, S; Xu, B

    2015-06-15

    Purpose: The purpose of this study is to investigate the LINAC repetition-rate (dose-rate) dependence of OCTAVIUS 1000SRS liquid ionization chamber (LIC) array for patient specific QA of SRT plans delivered with flattening-filter-free (FFF) beams. Methods: 1) The repetition-rate dependence of 1000SRS was measured in a phantom constructed with 5-cm solid water above and below the array for build-up and backscatter. A 0.3cc calibrated ion chamber was also placed along the central axis 2.3cm below the center chamber of the array for normalizing LINAC output fluctuation. The signals from the center chamber of the array under different repetition rates in the range of 400–2400 MU/min for 6xFFF and 10xFFF beams on a Varian TrueBeamSTx LINAC, normalized by the independent chamber readings, were analyzed for the array response dependence on repetition rates. 2) Twelve Step-and-shoot IMRS QA plans (6xFFF and 10xFFF) were delivered to the array under different repetition rates for analysis and comparison. 3) The absolute doses measured by the center chamber were compared to measurements using an independent ionization chamber with the identical setup, taken as the gold standard. 4) The correction factors based on the actual delivery repetition rate were applied to the measurements, and the results were compared again to the gold standard. Results: 1) The 1000SRS array exhibited repetition-rate dependence for FFF beams, up to 5% for 6xFFF and 10% for 10xFFF; 2) The array showed clinically-acceptable repetition-rate dependence for regular flattened beams; 3) This repetition-rate dependence significantly affected the measurement accuracy, thereby affecting IMRS QA results; 4) By applying an empirical repetition-rate correction, the corrected measurements agreed better with the gold standard ion chamber measurements. Conclusion: OCTAVIUS 1000SRS LIC array exhibited considerable repetition-rate dependence for FFF beams, which will affect the accuracy of the absolute QA

  12. The SLAC E-154 {sup 3}He polarimeter

    SciTech Connect

    Romalis, M. V.; Bogorad, P. L.; Cates, G. D.; Kumar, K. S.; Chupp, T. E.; Coulter, K. P.; Smith, T. B.; Welsh, R.; Hughes, E. W.; Johnson, J. R.; Thompson, A. K.

    1998-01-20

    We describe the NMR and Rb Zeeman frequency shift polarimeters used for determining the {sup 3}He polarization in a recent precision measurement of the neutron spin structure function g{sub 1} at SLAC (E-154). We performed a detailed study of the systematic errors associated with the calibration of the NMR polarimeter. A new technique was used for determining the {sup 3}He polarization from the frequency shift of the Rb Zeeman resonance.

  13. MIMAC-He3: MICRO-TPC MATRIX OF CHAMBERS OF 3He

    NASA Astrophysics Data System (ADS)

    Santos, D.; Guillaudin, O.; Lamy, Th.; Mayet, F.; Moulin, E.

    2007-08-01

    The project of a micro-TPC matrix of chambers of 3He for direct detection of non-baryonic dark matter is outlined. The privileged properties of 3He are highlighted. The double detection (ionization - projection of tracks) will assure the electron-recoil discrimination. The complementarity of MIMAC-He3 for supersymmetric dark matter search with respect to other experiments is illustrated. The modular character of the detector allows to have different gases to get A-dependence. The pressure degreee of freedom gives the possibility to work at high and low pressure. The low pressure regime gives the possibility to get the directionality of the tracks. The first measurements of ionization at very few keVs for 3He in 4He gas are described.

  14. [Experimental investigation of the collection efficiency of a PTW Roos ionization chamber irradiated with pulsed beams at high pulse dose with different pulse lengths].

    PubMed

    Karsch, Leonhard; Richter, Christian; Pawelke, Jörg

    2011-01-01

    In gas-filled ionization chambers as radiation detectors, the collection of the charge carriers is affected by the recombination effect. In dosimetry this effect must be accounted for by the saturation correction factor k(S). The physical description of the correction factor by Boag, Hochhäuser and Balk for pulsed radiation is well established. However, this description is only accurate when the pulse length is short compared to the collection time of the ionization chamber. In this work experimental investigations of the saturation correction factor have been made for pulses of 4 μ s up to pulse doses of about 230 mGy, and the theory of Boag, Hochhäuser and Balk was again confirmed. For longer pulses, however, the correction factor decreases and at a pulse duration of about 200μs reaches 75% of the value valid for short pulses. This reduced influence of the ion recombination is interpreted by the reaction kinetics of ion recombination as a second-order reaction. This effect is negligible for PTW Roos chambers at clinical linear accelerators with 4 μ s pulse duration for pulse doses up to 120 mGy.

  15. Absolute dose measurements by means of a small cylindrical ionization chamber for very high dose per pulse high energy electron beams

    SciTech Connect

    Karaj, E.; Righi, S.; Di Martino, F.

    2007-03-15

    Very high dose per pulse (3-13 cGy/pulse) high energy electron beams are currently produced by special linear accelerators (linac) dedicated to Intra Operative Radiation Therapy (IORT). The electron beams produced by such linacs are collimated by special Perspex applicators of various size and cylindrically shaped. The biggest problems from the dosimetric point of view are caused by the high dose-per-pulse values and the use of inclined applicators. In this work measurements of absolute dose for the inclined applicators were done by using a small cylindrical ionization chamber, type CC01 (Wellhofer), a parallel plane ionization chamber type Markus (PTW 23343) and radiochromic films type EBT. We show a method which allows calculating the quality correction factors for CC01 chamber with an uncertainty of 1% and the absolute dose value for the inclined applicators using CC01 with an uncertainty of 3.1% for electron beams of energy of 6 and 7 MeV produced by the linac dedicated to IORT Novac7.

  16. Hyperpolarized 3He diffusion MRI and histology in pulmonary emphysema.

    PubMed

    Woods, Jason C; Choong, Cliff K; Yablonskiy, Dmitriy A; Bentley, John; Wong, Jonathan; Pierce, John A; Cooper, Joel D; Macklem, Peter T; Conradi, Mark S; Hogg, James C

    2006-12-01

    Diffusion MRI of hyperpolarized (3)He shows that the apparent diffusion coefficient (ADC) of (3)He gas is highly restricted in the normal lung and becomes nearly unrestricted in severe emphysema. The nature of this restricted diffusion provides information about lung structure; however, no direct comparison with histology in human lungs has been reported. The purpose of this study is to provide information about (3)He gas diffusivity in explanted human lungs, and describe the relationship between (3)He diffusivity and the surface area to lung volume ratio (SA/V) and mean linear intercept (L(m)) measurements--the gold standard for diagnosis of emphysema. Explanted lungs from patients who were undergoing lung transplantation for advanced COPD, and donor lungs that were not used for transplantation were imaged via (3)He diffusion MRI. Histological measurements were made on the same specimens after they were frozen in the position of study. There is an inverse correlation between diffusivity and SA/V (and a positive correlation between diffusivity and L(m)). An important result is that restricted (3)He diffusivity separated normal from emphysematous lung tissue more clearly than the morphometric analyses. This effect may be due to the smaller histologic sampling size compared to the MRI voxel sizes.

  17. Photoneutron production of a Siemens Primus linear accelerator studied by Monte Carlo methods and a paired magnesium and boron coated magnesium ionization chamber system.

    PubMed

    Becker, J; Brunckhorst, E; Schmidt, R

    2007-11-07

    When radiotherapy with photon energies greater than 10 MV is performed neutrons contaminate the photon beam. In this paper the neutron contamination of the 15 MV photon mode of the Siemens Primus accelerator was studied. The Monte Carlo code MCNPX was used for the description of the treatment head and treatment room. The Monte Carlo results were verified by studying the photon depth dose curve and beam profiles in a water phantom. After these verifications the locations of neutron production were studied and the neutron source spectrum and strength were calculated. The neutron response of the paired Mg/Ar and MgB/Ar ionization chamber system was calculated and experimentally verified for two experimental set-ups. The paired chamber system allowed us to measure neutrons inside the field borders and allowed rapid and point wise measurement in contrast to other methods of neutron detection.

  18. Instantaneous and continuous measurement of /sup 14/C-labeled substrate oxidation to /sup 14/CO2 by minute tissue specimens: an ionization chamber method

    SciTech Connect

    Davidson, W.D.; Klein, K.L.; Kurokawa, K.; Soll, A.H.

    1981-06-01

    The vibrating reed electrometer and ionization chamber have been adapted for the instantaneous and continuous measurement of /sup 14/C-labeled substrate oxidation to /sup 14/CO2 by minute quantities of isolated tissues. This modified technique, utilizing a ''closed'' circulation incubation system, is 10-50 times as sensitive as the previously described ''open'' circulation techniques. Substrate oxidation curves are described for human erythrocytes and polymorphonuclear leucocytes, canine parietal cells and isolated segments of the rat nephron. This apparatus should prove to be a useful tool for metabolic studies of small quantities of isolated tissue.

  19. (18)F primary standard at ENEA-INMRI by three absolute techniques and calibration of a well-type IG11 ionization chamber.

    PubMed

    Capogni, Marco; Carconi, Pierluigi; De Felice, Pierino; Fazio, Aldo

    2016-03-01

    A new (18)F primary standardization carried out at ENEA-INMRI by three different absolute techniques, i.e. 4πγNaI(Tl)γ high-efficiency counting, TDCR and 4πβ(LS)-γ[NaI(Tl)] coincidence counting method, allowed the calibration of a fixed well-reentrant IG11 ionization chamber (IC), with an uncertainty lower than 1%, and to check the calibration factor of a portable well-type IC NPL-CRC model, previously calibrated. By the new standard the ENEA-INMRI was linked to the BIPM International Reference System (SIR) through the BIPM SIR Transfer Instrument (SIRTI).

  20. Polarized (3) He Spin Filters for Slow Neutron Physics.

    PubMed

    Gentile, T R; Chen, W C; Jones, G L; Babcock, E; Walker, T G

    2005-01-01

    Polarized (3)He spin filters are needed for a variety of experiments with slow neutrons. Their demonstrated utility for highly accurate determination of neutron polarization are critical to the next generation of betadecay correlation coefficient measurements. In addition, they are broadband devices that can polarize large area and high divergence neutron beams with little gamma-ray background, and allow for an additional spin-flip for systematic tests. These attributes are relevant to all neutron sources, but are particularly well-matched to time of flight analysis at spallation sources. There are several issues in the practical use of (3)He spin filters for slow neutron physics. Besides the essential goal of maximizing the (3)He polarization, we also seek to decrease the constraints on cell lifetimes and magnetic field homogeneity. In addition, cells with highly uniform gas thickness are required to produce the spatially uniform neutron polarization needed for beta-decay correlation coefficient experiments. We are currently employing spin-exchange (SE) and metastability-exchange (ME) optical pumping to polarize (3)He, but will focus on SE. We will discuss the recent demonstration of 75 % (3)He polarization, temperature-dependent relaxation mechanism of unknown origin, cell development, spectrally narrowed lasers, and hybrid spin-exchange optical pumping.

  1. Solar source regions of 3HE-rich particle events

    NASA Technical Reports Server (NTRS)

    Kahler, S. W.; Lin, R. P.; Reames, D. V.; Stone, R. G.; Liggett, M.

    1985-01-01

    Hydrogen alpha X-ray, and metric and kilometric radio data to examine the solar sources of energetic 3He-rich particle events observed near earth in association with impulsive 2 to 100 keV electron events were applied. Each 3He/electron event is associated with a kilometric type 3 burst belonging to a family of such bursts characterized by similar interplanetary propagation paths from the same solar active region. The 3He/electron events correlate very well with the interplanetary low frequency radio brightnesses of these events, but progressively worse with signatures from regions closer to the Sun. When H alpha brightnings can be associated with 3He/electron events, they have onsets coinciding to within 1 min of that of the associated metric type 3 burst but are often too small to be reported. The data are consistent with the earlier idea that many type 3 bursts, the 3He/electron events, are due to particle acceleration in the corona, well above the associated H alpha and X-ray flares.

  2. Optical Pumping / Spin Exchange ^3He Neutron Spin Filter Development

    NASA Astrophysics Data System (ADS)

    Hwang, Shenq-Rong; Coulter, Kevin P.; Chupp, Timothy E.; Welsh, Robert C.

    1998-04-01

    We have instrumented a thermal neutron beam line at the 2MW Ford reactor at the University of Michigan to develop a ^3He neutron spin filter test stand. Due to a large, spin depedent neutron cross section at low energies, polarized ^3He can be used as a neutron spin filter. Our ^3He spin filter is a 10 amagat-cm ^3He cell polarized via optical pumping/spin exchange with Rb. The filter is made of Corning 7056 glass filled with Rb , several atmosphere of ^3He and a few hundred torr nitrogen as buffer gas. We apply two 15W diode array lasers to optically pump Rb. In this presentation we will discuss some progress of this development, including a rotating oven design and a stepping motor driven neutron chopper. Preliminary results of the 10 amagat-cm filter will be presented and compared with theoretical calculations. A study of systematic errors from the data acquisition system and the neutron chopper will also be discussed.

  3. Polarized 3He Spin Filters for Slow Neutron Physics

    PubMed Central

    Gentile, T. R.; Chen, W. C.; Jones, G. L.; Babcock, E.; Walker, T. G.

    2005-01-01

    Polarized 3He spin filters are needed for a variety of experiments with slow neutrons. Their demonstrated utility for highly accurate determination of neutron polarization are critical to the next generation of betadecay correlation coefficient measurements. In addition, they are broadband devices that can polarize large area and high divergence neutron beams with little gamma-ray background, and allow for an additional spin-flip for systematic tests. These attributes are relevant to all neutron sources, but are particularly well-matched to time of flight analysis at spallation sources. There are several issues in the practical use of 3He spin filters for slow neutron physics. Besides the essential goal of maximizing the 3He polarization, we also seek to decrease the constraints on cell lifetimes and magnetic field homogeneity. In addition, cells with highly uniform gas thickness are required to produce the spatially uniform neutron polarization needed for beta-decay correlation coefficient experiments. We are currently employing spin-exchange (SE) and metastability-exchange (ME) optical pumping to polarize 3He, but will focus on SE. We will discuss the recent demonstration of 75 % 3He polarization, temperature-dependent relaxation mechanism of unknown origin, cell development, spectrally narrowed lasers, and hybrid spin-exchange optical pumping. PMID:27308140

  4. The effective point of measurement of ionization chambers and the build-up anomaly in MV x-ray beams.

    PubMed

    McEwen, M R; Kawrakow, I; Ross, C K

    2008-03-01

    A precision experimental investigation of the effective point of measurement (EPOM) of ion chambers in megavoltage beams has been carried out. A one-dimensional scanning phantom system was developed with an overall accuracy in the positioning of a chamber of better than 0.15 mm. Depth-dose data were acquired for a 25 MV beam from an Elekta Precise linac (field sizes of 10 x 10 cm and 25 x 25 cm) for measurement depths in the range 0.6-6 cm. The results confirmed the Monte Carlo calculations of an earlier theoretical investigation by Kawrakow [Med. Phys. 33, 1829-1839 (2006)] that the standard shift for cylindrical chambers, recommended in dosimetry protocols of -0.6r (where r is the internal radius of the cavity), is incorrect. A wide range of ion chambers were investigated and it was found that errors of up to 1.4 mm could occur for certain chamber designs (although typical errors for common chambers were around 0.5 mm). A comparison between measurements and Monte Carlo simulations showed that once the correct EPOM is used, the details of the linac geometry are correct, and the parameters of the electron beam striking the bremsstrahlung target have been adequately determined, the EGSnrc Monte Carlo package is capable of reproducing the experimental data to 0.2 mm or better. The investigation also confirmed that for the highest accuracy depth-dose curves in megavoltage photon beams one should use a well-guarded parallel-plate ion chamber. Three chamber designs were tested here and found to be satisfactory-the Scanditronix-Wellhöfer NACP-02, PTW Roos and Exradin All.

  5. Neutron (3He) Spin Structure Functions at Low Q^2

    SciTech Connect

    Vincent Sulkosky

    2009-07-01

    Experiment E97-110 was performed at the Thomas Jefferson National Accelerator Facility to provide a precise measurement of the $^{3}$He spin structure functions at low $Q^{2}$ from 0.02 to 0.3~[GeV$/c$]$^{2}$. A longitudinally-polarized electron beam was scattered from a longitudinally or transversely polarized $^{3}$He target. From these data, we have extracted moments of the neutron and $^{3}$He spin structure functions at very low momentum transfers. These data allow us to make a benchmark check of Chiral Perturbation Theory calculations in a region where they are expected to be valid. In these proceedings, the experimental details are discussed and preliminary results on the first moments of the $g_1\\left(x,Q^{2}\\right)$ and $g_2\\left(x,Q^{2}\\right)$ structure functions are presented.

  6. Feasibility of neutron diffraction on solid 3He

    NASA Astrophysics Data System (ADS)

    Siemensmeyer, K.; Schuberth, E. A.; Adams, E. D.; Takano, Y.; Guckelsberger, K.

    2000-07-01

    We have investigated the feasibility of neutron diffraction from solid 3He. The experiment will be performed at the HMI, first aiming for the properties of the antiferromagnetic ordering in the BCC phase and the ferromagnetic order in the HCP phase. Signal and beam heating considerations are essential to account for the enormous neutron absorption cross section of 3He. The study shows that neutron diffraction and transmission experiments are possible, relying on the experience gained from the neutron diffraction experiments on Cu and Ag at nanokelvin temperatures. A pressure cell has been developed which complies with the conflicting demands arising from the neutron and ultralow temperature aspects of the experiment. This work is a first step in an extensive effort to characterize 3He by neutron diffraction.

  7. Strong-Coupling and the Stripe Phase of ^3He

    NASA Astrophysics Data System (ADS)

    Wiman, Joshua J.; Sauls, J. A.

    2016-09-01

    Thin films of superfluid 3He were predicted, based on weak-coupling BCS theory, to have a stable phase which spontaneously breaks translational symmetry in the plane of the film. This crystalline superfluid, or "stripe" phase, develops as a one-dimensional periodic array of domain walls separating degenerate B phase domains. We report calculations of the phases and phase diagram for superfluid 3He in thin films using a strong-coupling Ginzburg-Landau theory that accurately reproduces the bulk 3He superfluid phase diagram. We find that the stability of the Stripe phase is diminished relative to the A phase, but the Stripe phase is stable in a large range of temperatures, pressures, confinement, and surface conditions.

  8. Quark-Hadron Duality in Neutron (3He) Spin Structure

    SciTech Connect

    Solvignon, Patricia; Liyanage, Nilanga; Chen, Jian-Ping; Choi, Seonho; Aniol, Konrad; Averett, Todd; Boeglin, Werner; Camsonne, Alexandre; Cates, Gordon; Chang, C.; Chang, C.C.; Chang, C.; Chang, C.C.; Chudakov, Eugene; Craver, Brandon; Cusanno, Francesco; Deur, Alexandre; Dutta, Dipangkar; Ent, Rolf; Feuerbach, Robert; Frullani, Salvatore; Gao, Haiyan; Garibaldi, Franco; Gilman, Ronald; Glashausser, Charles; Gorbenko, Viktor; Hansen, Jens-Ole; Higinbotham, Douglas; Ibrahim, Hassan; Jiang, Xiaodong; Jones, Mark; Kelleher, Aidan; Kelly, J.; Keppel, Cynthia; Kim, Wooyoung; Korsch, Wolfgang; Kramer, Kevin; Kumbartzki, Gerfried; LeRose, John; Lindgren, Richard; Ma, Bin; Margaziotis, Demetrius; Markowitz, Pete; McCormick, Kathy; Meziani, Zein-Eddine; Michaels, Robert; Moffit, Bryan; Monaghan, Peter; Munoz-Camacho, Carlos; Paschke, Kent; Reitz, Bodo; Saha, Arunava; Sheyor, Ran; Singh, Jaideep; Slifer, Karl; Sulkosky, Vince; Sulkosky, Vincent; Sulkosky, Vince; Sulkosky, Vincent; Tobias, William; Urciuoli, Guido; Wang, Kebin; Wijesooriya, Krishni; Wojtsekhowski, Bogdan; Woo, Seungtae; Yang, Jae-Choon; Zheng, Xiaochao; Zhu, Lingyan

    2008-10-01

    We present experimental results of the first high-precision test of quark-hadron duality in the spin-structure function g_1 of the neutron and $^3$He using a polarized 3He target in the four-momentum-transfer-squared range from 0.7 to 4.0 (GeV/c)^2. Global duality is observed for the spin-structure function g_1 down to at least Q^2 = 1.8 (GeV/c)^2 in both targets. We have also formed the photon-nucleon asymmetry A_1 in the resonance region for 3He and found no strong Q^2-dependence above 2.2 (GeV/c)^2.

  9. Ultrasensitive 3He magnetometer for measurements of high magnetic fields

    NASA Astrophysics Data System (ADS)

    Nikiel, Anna; Blümler, Peter; Heil, Werner; Hehn, Manfred; Karpuk, Sergej; Maul, Andreas; Otten, Ernst; Schreiber, Laura M.; Terekhov, Maxim

    2014-11-01

    We describe a 3He magnetometer capable to measure high magnetic fields ( B> 0.1 T) with a relative accuracy of better than 10-12. Our approach is based on the measurement of the free induction decay of gaseous, nuclear spin polarized 3He following a resonant radio frequency pulse excitation. The measurement sensitivity can be attributed to the long coherent spin precession time T2 ∗ being of order minutes which is achieved for spherical sample cells in the regime of "motional narrowing" where the disturbing influence of field inhomogeneities is strongly suppressed. The 3He gas is spin polarized in situ using a new, non-standard variant of the metastability exchange optical pumping. We show that miniaturization helps to increase T2 ∗ further and that the measurement sensitivity is not significantly affected by temporal field fluctuations of order 10-4.

  10. 3He Neutron Detector Pressure Effect and Comparison to Models

    SciTech Connect

    Kouzes, Richard T.; Ely, James H.; Lintereur, Azaree T.; Siciliano, Edward R.; Stromswold, David C.; Woodring, Mitchell L.

    2010-01-14

    Reported here are the results of measurements performed to determine the efficiency of 3He filled proportional counters as a function of gas pressure in the SAIC system. Motivation for these measurements was largely to validate the current model of the SAIC system. Those predictions indicated that the neutron detection efficiency plotted as a function of pressure has a simple, logarithmic shape. As for absolute performance, the model results indicated the 3He pressure in the current SAIC system could not be reduced appreciably while meeting the current required level of detection sensitivity. Thus, saving 3He by reducing its pressure was predicted not to be a viable option in the current SAIC system.

  11. Quark-hadron duality in neutron (3He) spin structure.

    PubMed

    Solvignon, P; Liyanage, N; Chen, J-P; Choi, Seonho; Aniol, K; Averett, T; Boeglin, W; Camsonne, A; Cates, G D; Chang, C C; Chudakov, E; Craver, B; Cusanno, F; Deur, A; Dutta, D; Ent, R; Feuerbach, R; Frullani, S; Gao, H; Garibaldi, F; Gilman, R; Glashausser, C; Gorbenko, V; Hansen, O; Higinbotham, D W; Ibrahim, H; Jiang, X; Jones, M; Kelleher, A; Kelly, J; Keppel, C; Kim, W; Korsch, W; Kramer, K; Kumbartzki, G; Lerose, J J; Lindgren, R; Ma, B; Margaziotis, D J; Markowitz, P; McCormick, K; Meziani, Z-E; Michaels, R; Moffit, B; Monaghan, P; Munoz Camacho, C; Paschke, K; Reitz, B; Saha, A; Sheyor, R; Singh, J; Slifer, K; Sulkosky, V; Tobias, A; Urciuoli, G M; Wang, K; Wijesooriya, K; Wojtsekhowski, B; Woo, S; Yang, J-C; Zheng, X; Zhu, L

    2008-10-31

    We present experimental results of the first high-precision test of quark-hadron duality in the spin-structure function g_{1} of the neutron and 3He using a polarized 3He target in the four-momentum-transfer-squared range from 0.7 to 4.0 (GeV/c);{2}. Global duality is observed for the spin-structure function g_{1} down to at least Q;{2}=1.8 (GeV/c);{2} in both targets. We have also formed the photon-nucleon asymmetry A1 in the resonance region for 3He and found no strong Q2 dependence above 2.2 (GeV/c);{2}.

  12. 3He spin exchange cells for magnetic resonance imaging

    NASA Astrophysics Data System (ADS)

    Jacob, R. E.; Morgan, S. W.; Saam, B.

    2002-08-01

    We present a protocol for the consistent fabrication of glass cells to provide hyperpolarized (HP) 3He for pulmonary magnetic resonance imaging. The method for producing HP 3He is spin-exchange optical pumping. The valved cells must hold of order 1 atm[middle dot]L of gas at up to 15 atm pressure. Because characteristic spin-exchange times are several hours, the longitudinal nuclear relaxation time T1 for 3He must be several tens of hours and robust with respect to repeated refilling and repolarization. Collisions with the cell wall are a significant and often dominant cause of relaxation. Consistent control of wall relaxation through cell fabrication procedures has historically proven difficult. With the help of the discovery of an important mechanism for wall relaxation that involves magnetic surface sites in the glass, and with the further confirmation of the importance of Rb metal to long wall-relaxation times, we have developed a successful protocol for fabrication of 3He spin exchange cells from inexpensive and easily worked borosilicate (Pyrex) glass. The cells are prepared under vacuum using a high-vacuum oil-free turbomolecular pumping station, and they are sealed off under vacuum after [greater-than-or-equal, slanted]100 mg of distilled Rb metal is driven in. Filling of cells with the requisite 3He-N2 mixture is done on an entirely separate gas-handling system. Our cells can be refilled and the gas repolarized indefinitely with no significant change in their wall properties. Relaxation data are presented for about 30 cells; the majority of these reach a "40/40" benchmark: T1>40 h, and 3He polarizations reach or exceed 40%. Typical polarization times range from 12 to 20 h; 20% polarization can be achieved in 3-5 h.

  13. Neutron-scattering experiment on solid 3He

    NASA Astrophysics Data System (ADS)

    Mat'aš, S.; Bat'ko, I.; Boyko, V.; Schöttl, S.; Siemensmeyer, K.; Raasch, S.; Radulov, I.; Adams, E. D.; Scherline, T. E.

    The central aim of our work is the characterisation of magnetic and crystallographic properties of solid 3He on a microscopic scale. This can only be achieved using neutron-diffraction techniques. The potential of neutron methods in magnetism and their application to nuclear magnetism is well known. They were very successful in the recent investigation of spontaneous nuclear order in copper and silver. The high neutron absorption cross section makes the application of neutron diffraction in solid 3He very difficult - but a careful feasibility study of diffraction experiments shows that new results of fundamental importance in the field of magnetism may be gained.

  14. Anisotropic Phases of Superfluid 3He in Compressed Aerogel

    NASA Astrophysics Data System (ADS)

    Li, J. I. A.; Zimmerman, A. M.; Pollanen, J.; Collett, C. A.; Halperin, W. P.

    2015-03-01

    It has been shown that the relative stabilities of various superfluid states of 3He can be influenced by anisotropy in a silica aerogel framework. We prepared a suite of aerogel samples compressed up to 30% for which we performed pulsed NMR on 3He imbibed within the aerogel. We identified A and B phases and determined their magnetic field-temperature phase diagrams as a function of strain. From these results, we infer that the B phase is distorted by negative strain forming an anisotropic superfluid state more stable than the A phase.

  15. Conception and realization of a parallel-plate free-air ionization chamber for the absolute dosimetry of an ultrasoft X-ray beam

    NASA Astrophysics Data System (ADS)

    Groetz, J.-E.; Ounoughi, N.; Mavon, C.; Belafrites, A.; Fromm, M.

    2014-08-01

    We report the design of a millimeter-sized parallel plate free-air ionization chamber (IC) aimed at determining the absolute air kerma rate of an ultra-soft X-ray beam (E = 1.5 keV). The size of the IC was determined so that the measurement volume satisfies the condition of charged-particle equilibrium. The correction factors necessary to properly measure the absolute kerma using the IC have been established. Particular attention was given to the determination of the effective mean energy for the 1.5 keV photons using the PENELOPE code. Other correction factors were determined by means of computer simulation (COMSOL™and FLUKA). Measurements of air kerma rates under specific operating parameters of the lab-bench X-ray source have been performed at various distances from that source and compared to Monte Carlo calculations. We show that the developed ionization chamber makes it possible to determine accurate photon fluence rates in routine work and will constitute substantial time-savings for future radiobiological experiments based on the use of ultra-soft X-rays.

  16. Conception and realization of a parallel-plate free-air ionization chamber for the absolute dosimetry of an ultrasoft X-ray beam

    SciTech Connect

    Groetz, J.-E. Mavon, C.; Fromm, M.; Ounoughi, N.; Belafrites, A.

    2014-08-15

    We report the design of a millimeter-sized parallel plate free-air ionization chamber (IC) aimed at determining the absolute air kerma rate of an ultra-soft X-ray beam (E = 1.5 keV). The size of the IC was determined so that the measurement volume satisfies the condition of charged-particle equilibrium. The correction factors necessary to properly measure the absolute kerma using the IC have been established. Particular attention was given to the determination of the effective mean energy for the 1.5 keV photons using the PENELOPE code. Other correction factors were determined by means of computer simulation (COMSOL™and FLUKA). Measurements of air kerma rates under specific operating parameters of the lab-bench X-ray source have been performed at various distances from that source and compared to Monte Carlo calculations. We show that the developed ionization chamber makes it possible to determine accurate photon fluence rates in routine work and will constitute substantial time-savings for future radiobiological experiments based on the use of ultra-soft X-rays.

  17. High energy photon reference for radiation protection: technical design of the LINAC beam and ionization chambers; and calculation of monoenergetic conversion coefficients

    NASA Astrophysics Data System (ADS)

    Dusciac, D.; Bordy, J.-M.; Daures, J.; Blideanu, V.

    2016-09-01

    In this work, we present the results of the first part of a research project aimed at offering a complete response to dosimeters providers and nuclear physicists' demands for high-energy (6 - 9 MeV) photon beams for radiation protection purposes. Classical facilities allowing the production of high-energy photonic radiation (proton accelerators, nuclear reactors) are very rare and need large investment for development and use. A novel solution is proposed, consisting in the use of a medical linear accelerator, allowing a significant decrease of all costs.Using Monte Carlo simulations (MCNP5 and PENELOPE codes), a specifically designed electron-photon conversion target allowing for obtaining a high energy photon beam (with an average energy weighted by fluence of about 6 MeV) has been built for radiation protection purposes. Due to the specific design of the target, this "realistic" radiation protection high-energy photon beam presents a uniform distribution of air kerma rate at a distance of 1 m, over a 30 × 30 cm2 surface. Two graphite cavity ionizing chambers for ionometric measurements have been built. For one of these chambers, the charge collection volume has been measured allowing for its use as a primary standard. The second ionizing chamber is used as a transfer standard; as such it has been calibrated in a 60Co beam, and in the high energy photon beam for radiation protection.The measurements with these ionizing chambers allowed for an evaluation of the air kerma rate in the LINAC based high-energy photon beam for radiation protection: the values cover a range between 36 mGy/h and 210 mGy/h, compatible with radiation protection purposes.Finally, using Monte Carlo simulations, conversion coefficients from air kerma to dose equivalent quantities have been calculated in the range between 10 keV and 22.4 MeV, for the spectral distribution of the fluence corresponding to the beam produced by the linear accelerator of the LNE-LNHB.

  18. Comparison of various stopping gases for 3He-based position sensitive neutron detectors

    NASA Astrophysics Data System (ADS)

    Doumas, A.; Smith, G. C.

    2012-05-01

    A range of solid state, scintillator and gas based detectors are being developed for use at the next generation of high flux neutron facilities. Since gas detectors are expected to continue to play a key role in future specific thermal neutron experiments, a comparison of the performance characteristics of prospective stopping gases is beneficial. Gas detectors typically utilize the reaction 3He(n,p)t to detect thermal neutrons; the 3He gas is used in a mixture containing a particular stopping gas in order to maintain relatively short ranges for the proton and triton pair emitted from the n-3He reaction. Common stopping gases include hydrocarbons (e.g. propane), carbon tetrafluoride, and noble gases such as argon and xenon. For this study, we utilized the Monte Carlo simulation code "Stopping and Range of Ions in Matter" to analyze the expected behavior of argon, xenon, carbon dioxide, difluoroethane and octafluoropropane as stopping gases for thermal neutron detectors. We also compare these findings to our previously analyzed performance of propane, butane and carbon tetrafluoride. A discussion of these gases includes their behavior in terms of proton and triton range, ionization distribution and straggle.

  19. Stability and Spectra of Small 3He-4He Clusters

    NASA Astrophysics Data System (ADS)

    Navarro, J.; Fantoni, S.; Guardiola, R.; Zuker, A.

    Diffusion Monte Carlo calculations have been systematically performed to analyze the stability of small mixed 3He-4He clusters, as well as their excitation spectra. The picture that emerges is that of systems with strong shell effects whose binding and excitation energies are essentially determined by the monopole properties of an effective Hamiltonian.

  20. Progress in Polarized 3He Ion Source at RCNP

    SciTech Connect

    Tanaka, M.; Takahashi, Y.; Shimoda, T.; Yasui, S.; Yosoi, M.; Takahisa, K.; Shimakura, N.; Plis, Yu. A.; Donets, E. D.

    2007-06-13

    A long history on the polarized 3He ion source developed at RCNP is presented. We started with an 'OPPIS' (Optical Pumping Polarized Ion Source) and later found the fundamental difficulties in the OPPIS. To overcome them an 'EPPIS' (Electron Pumping Polarized Ion Source) was proposed and its validity was experimentally proven. However, a serious technical disadvantage was also found in the EPPIS. To avoid this disadvantage we proposed a new concept, 'SEPIS' (Spin Exchange Polarized Ion Source), which uses an enhanced spin-exchange cross section theoretically expected at low 3He+ incident energies in the 3He+ + Rb system. Next, we describe the present status of the SEPIS development: construction of a bench test device allowing the measurements of not only the spin-exchange cross sections {sigma}se but also the electron capture cross sections {sigma}ec for the 3He+ + Rb system. The latest experimental data on {sigma}ec are presented and compared with other previous experimental data and the theoretical calculations.Finally, a design study of the SEPIS for practical use in nuclear (cyclotron) and particle physics (synchrotron) is shortly mentioned.

  1. {sup 3}He neutral current detectors at SNO

    SciTech Connect

    Elliott, S.R.; Browne, M.C.; Doe, P.J.

    1998-09-01

    The flux of solar neutrinos measured via charged and neutral current interactions can provide a model independent test of neutrino oscillations. Since the Sudbury Neutrino Observatory uses heavy water as a target, it has a large sensitivity to both interactions. A technique for observing the neutral current breakup of the deuteron using {sup 3}He proportional counters is described.

  2. Minimal mass size of a stable {sup 3}He cluster

    SciTech Connect

    Guardiola, R.; Navarro, J.

    2005-03-01

    The minimal number of {sup 3}He atoms required to form a bound cluster has been estimated by means of a diffusion Monte Carlo procedure within the fixed-node approximation. Several importance sampling wave functions have been employed in order to consider different shell-model configurations. The resulting upper bound for the minimal number is 32 atoms.

  3. Symmetry protected topological superfluid (3)He-B.

    PubMed

    Mizushima, Takeshi; Tsutsumi, Yasumasa; Sato, Masatoshi; Machida, Kazushige

    2015-03-25

    Owing to the richness of symmetry and well-established knowledge of bulk superfluidity, the superfluid (3)He has offered a prototypical system to study intertwining of topology and symmetry. This article reviews recent progress in understanding the topological superfluidity of (3)He in a multifaceted manner, including symmetry considerations, the Jackiw-Rebbi's index theorem, and the quasiclassical theory. Special focus is placed on the symmetry protected topological superfuidity of the (3)He-B confined in a slab geometry. The (3)He-B under a magnetic field is separated to two different sub-phases: the symmetry protected topological phase and non-topological phase. The former phase is characterized by the existence of symmetry protected Majorana fermions. The topological phase transition between them is triggered by the spontaneous breaking of a hidden discrete symmetry. The critical field is quantitatively determined from the microscopic calculation that takes account of magnetic dipole interaction of the (3)He nucleus. It is also demonstrated that odd-frequency even-parity Cooper pair amplitudes are emergent in low-lying quasiparticles. The key ingredients, symmetry protected Majorana fermions and odd-frequency pairing, bring an important consequence that the coupling of the surface states to an applied field is prohibited by the hidden discrete symmetry, while the topological phase transition with the spontaneous symmetry breaking is accompanied by anomalous enhancement and anisotropic quantum criticality of surface spin susceptibility. We also illustrate common topological features between topological crystalline superconductors and symmetry protected topological superfluids, taking UPt3 and Rashba superconductors as examples.

  4. Direct measurement of absorbed dose to water in HDR {sup 192}Ir brachytherapy: Water calorimetry, ionization chamber, Gafchromic film, and TG-43

    SciTech Connect

    Sarfehnia, Arman; Kawrakow, Iwan; Seuntjens, Jan

    2010-04-15

    Purpose: Gafchromic film and ionometric calibration procedures for HDR {sup 192}Ir brachytherapy sources in terms of dose rate to water are presented and the experimental results are compared to the TG-43 protocol as well as with the absolute dose measurement results from a water calorimetry-based primary standard. Methods: EBT-1 Gafchromic films, an A1SL Exradin miniature Shonka thimble type chamber, and an SI HDR 1000 Plus well-type chamber (Standard Imaging, Inc., Middleton, WI) with an ADCL traceable S{sub k} calibration coefficient (following the AAPM TG-43 protocol) were used. The Farmer chamber and Gafchromic film measurements were performed directly in water. All results were compared to direct and absolute absorbed dose to water measurements from a 4 deg. C stagnant water calorimeter. Results: Based on water calorimetry, the authors measured the dose rate to water to be 361{+-}7 {mu}Gy/(h U) at a 55 mm source-to-detector separation. The dose rate normalized to air-kerma strength for all the techniques agree with the water calorimetry results to within 0.83%. The overall 1-sigma uncertainty on water calorimetry, ionization chamber, Gafchromic film, and TG-43 dose rate measurement amounts to 1.90%, 1.44%, 1.78%, and 2.50%, respectively. Conclusions: This work allows us to build a more realistic uncertainty estimate for absorbed dose to water determination using the TG-43 protocol. Furthermore, it provides the framework necessary for a shift from indirect HDR {sup 192}Ir brachytherapy dosimetry to a more accurate, direct, and absolute measurement of absorbed dose to water.

  5. Correction factors for the NMi free-air ionization chamber for medium-energy x-rays calculated with the Monte Carlo method.

    PubMed

    Grimbergen, T W; van Dijk, E; de Vries, W

    1998-11-01

    A new method is described for the determination of x-ray quality dependent correction factors for free-air ionization chambers. The method is based on weighting correction factors for mono-energetic photons, which are calculated using the Monte Carlo method, with measured air kerma spectra. With this method, correction factors for electron loss, scatter inside the chamber and transmission through the diaphragm and front wall have been calculated for the NMi free-air chamber for medium-energy x-rays for a wide range of x-ray qualities in use at NMi. The newly obtained correction factors were compared with the values in use at present, which are based on interpolation of experimental data for a specific set of x-ray qualities. For x-ray qualities which are similar to this specific set, the agreement between the correction factors determined with the new method and those based on the experimental data is better than 0.1%, except for heavily filtered x-rays generated at 250 kV. For x-ray qualities dissimilar to the specific set, differences up to 0.4% exist, which can be explained by uncertainties in the interpolation procedure of the experimental data. Since the new method does not depend on experimental data for a specific set of x-ray qualities, the new method allows for a more flexible use of the free-air chamber as a primary standard for air kerma for any x-ray quality in the medium-energy x-ray range.

  6. SU-E-T-414: Experimental Correction of High-Z Electrode Effect in Mini-Ionization Chambers for Small Beam Dosimetry

    SciTech Connect

    Larraga-Gutierrez, J

    2015-06-15

    Purpose: To correct for the over-response of mini-ionization chambers with high-Z central electrodes. The hypothesis is that by applying a negative/reverse voltage, it is possible to suppress the signal generated in the high-Z central electrode by low-energy photons. Methods: The mini-ionization chambers used in the experiments were a PTW-31014, PTW-31006 and IBA-CC01. The PTW-31014 has an aluminum central electrode while the PTW-31006 and IBA-CC01 have a steel one. Total scatter factors (Scp) were measured for a 6 MV photon beam down to a square field size of 0.5 cm. The measurements were performed in water at 10 cm depth with SAD of 100 cm. The Scp were measured with the dosimeters with +400V bias voltage. In the case of the PTW-31006 and IBA-CC01, the measurements were repeated with −400V bias voltage. Also, the field factors in water were calculated with Monte Carlo simulations for comparison. Results: The measured Scp at +400V with the PTW-31006 and IBA-CC01 detectors were in agreement within 0.2% down to a field size of 1.5 cm. Both dosimeters shown a systematic difference about 2.5% with the Scp measured with the PTW-31014 and the Monte Carlo calculated field factors. The measured Scp at −400V with the PTW-31006 and IBA-CC01 detectors were in close agreement with the PTW-31014 measured Scp and the field factors within 0.3 and 1.0%, respectively. In the case of the IBA-CC01 it was found a good agreement (1%) down to field size of 1.0 cm. All the dosimeters shown differences up to 17% between the measured Scp and the field factor for the 0.5 cm field size. Conclusion: By applying a negative/reverse voltage to the mini-ionization chambers with high-Z central electrode it was possible to correct for their over-response to low energy photons.

  7. Acceleration of 3HE and heavy ions at interplanetary shocks

    NASA Astrophysics Data System (ADS)

    Desai, M. I.; Mason, G. M.; Dwyer, J. R.; Mazur, J. E.; Smith, C. W.; Koug, R. M.

    2001-08-01

    We have surveyed the 0.5-2.0 MeV nucleon-1 ion composition of 56 interplanetary shocks (IP) observed with the Ultra-Low-Energy Isotope Spectrometer (ULEIS) on board the Advanced Composition Explorer (ACE) from 1997 October 1 through 2000 November 30. Our results show the first ever measurement (25 cases) of 3 He ions being accelerated at IP shocks. The 3 He/4 He ratio at the 25 shocks exhibited a wide range of values between 0.00140.24; the ratios were enhanced between factors of ~3-600 over the solar wind value. During the survey period, the occurrence probability of 3 He-rich shocks increased with rising solar activity as measured in terms of the daily occurrence rates of sunspots and X-ray flares. The 3 He enhancements at IP shocks cannot be attributed to rigidity dependent acceleration of solar wind ions and are better explained if the shocks accelerate ions from multiple sources, one being remnant impulsive solar flare material enriched in 3 He ions. Our results also indicate that the contribution of impulsive flares to the seed population for IP shocks varies from event to event, and that the interplanetary medium is being replenished with impulsive material more frequently during periods of increased solar activity. 1. Introduction Enhancements in the intensities of energetic ions associated with transient interplanetary (IP) shocks have been observed routinely at 1 AU since the 1960's (e.g., Reames 1999). It is presently believed that the majority of such IP shocks are driven by fast coronal mass ejections or CMEs as they propagate through interplanetary space (e.g., Gosling 1993), and that the associated ion intensity enhancements are due to diffusive shock acceleration of solar wind ions (Lee 1983; Jones and Ellison 1991; Reames 1999). However, the putative solar wind origin of the IP-shock accelerated ions is based on composition measurements associated with a very limited number of individual IP shocks (Klecker et al. 1981; Hovestadt et al. 1982; Tan et

  8. Evidence for Split NMR Lines in Ferromagnetic 3He Films

    NASA Astrophysics Data System (ADS)

    Guo, Lei; Zhang, Jinshan; Du, Yuliang; Gould, C. M.; Bozler, H. M.

    2006-09-01

    In earlier experiments on ferromagnetic 3He films, we observed a complex lineshape due in part to the dipolar field generated by polarization of the 3He nuclei. Much of the complex lineshape can be explained by the known distribution of the Grafoil platelets. However, there remained some evidence for a split NMR line at some temperatures. In our new experiments on ZYX grade exfoliated graphite where the size of individual platelets is much larger and the angular distribution is three times smaller, this splitting has become more evident over a wider range of temperatures. Now it is clear that the complex lineshape includes two peaks along with remaining orientation effects. We also find that roughly 2% of our signal comes from randomly oriented platelets. We present the details of our model for analyzing these lineshapes and the experimental results for the line splitting at several coverages in the ferromagnetic range. We discuss the possible sources of this line splitting.

  9. Proton polarization from π+ absorption in 3He

    NASA Astrophysics Data System (ADS)

    Maytal-Beck, S.; Aclander, J.; Altman, A.; Ashery, D.; Hahn, H.; Moinester, M. A.; Rahav, A.; Feltham, A.; Jones, G.; Pavan, M.; Sevior, M.; Hutcheon, D.; Ottewell, D.; Smith, G. R.; Niskanen, J. A.

    1992-05-01

    We present the first polarization measurements for pion absorption on a nucleus heavier than the deuteron. The polarization of protons resulting from π+ absorption in the 3He was measured at bombarding energies of 120 and 250 MeV. Protons from absorption in a quasideuteron were selected by applying kinematical constraints. A significant discrepancy was observed between the experimental results and theoretical predictions. At 120 MeV the measured polarizations for 3He are consistent with those of the deuteron. At 250 MeV the angular distribution of the polarization is significantly different than for the deuteron, showing sensitivity to the nuclear density, and thus may be sensitive to short range correlations between nucleons.

  10. Internal Magnus effects in superfluid 3He-A

    NASA Astrophysics Data System (ADS)

    Salmelin, R. H.; Salomaa, M. M.; Mineev, V. P.

    The orbital angular momentum of the coherently aligned Cooper pairs in superfluid (3)He-A is transmitted to an object immersed in the condensate. The authors evaluate the quasiparticle-scattering asymmetry experienced by a negative ion; this leads to a measurable, purely quantum-mechanical Magnus force deflecting the ion's trajectory. Close to T(sub c), possible hydrodynamic Magnus effects are smaller by the factor delta sub A/(k sub B)(T sub c).

  11. Thermal Conductivity of Spin-Polarized Liquid {sup 3}He

    SciTech Connect

    Sawkey, D.; Puech, L.; Wolf, P.E.

    2006-06-02

    We present the first measurements of the thermal conductivity of spin-polarized normal liquid {sup 3}He. Using the rapid melting technique to produce nuclear polarizations up to 0.7, and a vibrating wire both as a heater and a thermometer, we show that, unlike the viscosity, the conductivity increases much less than predicted for s-wave scattering. We suggest that this might be due to a small probability for head-on collisions between quasiparticles.

  12. Hard Two-body Photodisintegration of ^3He

    SciTech Connect

    Pomerantz, Ishay Ari; Ilieva, Yordanka Yordanova; Gilman, Ronald; Higinbotham, Douglas W.; Piasetzky, Eliazer Israel; Strauch, Steffen

    2013-06-01

    We have measured cross sections for the {gamma}+{sup 3}He->p+d reaction at photon energies of 0.4 - 1.4 GeV and a center-of-mass angle of 90 deg. We observe dimensional scaling above 0.7 GeV at this center-of-mass angle. This is the first observation of dimensional scaling in the photodisintegration of a nucleus heavier than the deuteron.

  13. NOVEL CONCEPTS FOR ISOTOPIC SEPARATION OF 3HE/4HE

    SciTech Connect

    Roy, L.; Nigg, H.; Watson, H.

    2012-09-04

    The research outlined below established theoretical proof-of-concept using ab initio calculations that {sup 3}He can be separated from {sup 4}He by taking advantage of weak van der Waals interactions with other higher molecular weight rare gases such as xenon. To the best of our knowledge, this is the only suggested method that exploits the physical differences of the isotopes using a chemical interaction.

  14. Uranium Neutron Coincidence Collar Model Utilizing 3He

    SciTech Connect

    Siciliano, Edward R.; Rogers, Jeremy L.; Schweppe, John E.; Lintereur, Azaree T.; Kouzes, Richard T.

    2012-07-30

    The Department of Energy Office of Nuclear Safeguards (NA-241) is supporting the project 'Coincidence Counting With Boron-Based Alternative Neutron Detection Technology' at Pacific Northwest National Laboratory (PNNL) for development of an alternative neutron coincidence counter. The goal of this project is to design, build and demonstrate a boron-lined proportional tube based alternative system in a configuration typically used for 3He-based coincidence counter applications. The specific application selected for boron-lined tube replacement in this project was one of the Uranium Neutron Coincidence Collar (UNCL) designs. This report, providing results for model development of a UNCL, is a deliverable under Task 2 of the project. The current UNCL instruments utilize 3He tubes. As the first step in developing and optimizing a boron-lined proportional counter based version of the UNCL, models of eight different 3He-based UNCL detectors currently in use were developed and evaluated. A comparison was made between the simulated results and measured efficiencies for those systems with values reported in the literature. The reported experimental measurements for efficiencies and die-away times agree to within 10%.

  15. Incorporating metal into polarized 3He target cells

    NASA Astrophysics Data System (ADS)

    Katugampola, Sumudu K.; Matyas, Daniel J.; Wang, Yunxiao; Tobias, William A.; Nelyubin, Vladimir; Cates, Gordon D.

    2017-01-01

    An upcoming measurement at Jefferson Laboratory (JLab) of the electric form factor of the neutron will utilize a polarized 3He target at high luminosity. While polarized 3He targets at JLab have previously been made entirely of glass, we describe progress toward incorporating metal windows for the electron beam. Under the conditions of our targets, very few studies have been done on the spin-relaxation of nuclear-polarized 3He on metal surfaces. We have found good performance by using Oxygen Free High Conductivity (OFHC) copper substrates electroplated with gold. The glass-to-metal transitions within our test cells were based on Housekeeper seals. We have further established that Uranium glass (Canary glass) has excellent spin-relaxation properties, and can serve as a transition glass from Pyrex to Aluminosilicate glass (GE180). Another finding was that spin-relaxation properties were sensitive to the manner in which cells were annealed, an important issue because of constraints when annealing cells containing both metal and glass.

  16. Chiral Phases of Superfluid 3He in an Anisotropic Medium

    NASA Astrophysics Data System (ADS)

    Sauls, James

    2013-03-01

    I report theoretical results for the phases of superfluid 3He infused into homogeneous uniaxial aerogel. Ginzburg-Landau (GL) theory for a class of equal-spin-pairing (ESP) states in a medium with uniaxial anisotropy is developed and used to analyze recent experiments on uniaxially strained aerogels. For 3He in an axially ``stretched'' aerogel GL theory predicts a transition from normal liquid into a chiral ABM phase in which the chirality axis is aligned along the strain axis. This state is protected from random fluctuations in the anisotropy direction, has a positive NMR shift, a sharp NMR resonance line and is in quantitative agreement with NMR in the high-temperature ESP-1 phase of superfluid 3He in axially stretched aerogel. A second transition into a bi-axial phase is predicted to onset at a slightly lower temperature. This phase is an ESP state, breaks time-reversal symmetry, and is defined by an order parameter that spontaneously breaks axial rotation symmetry. The bi-axial phase has a continuous degeneracy associated with broken axial symmetry. Theoretical predictions for the NMR frequency shifts provide an identification of the ESP-2 phase as the bi-axial state, partially disordered by random anisotropy (Larkin-Imry-Ma effect). Supported by National Science Foundation Grant DMR-1106315.

  17. Resonant quasiparticle-ion scattering in anisotropic superfluid 3He

    NASA Astrophysics Data System (ADS)

    Salmelin, R. H.; Salomaa, M. M.

    1990-03-01

    Low-energy excitations in quantum fluids are most directly encountered by ions. In the superfluid phases of 3He the relevant elementary excitations are Bogoliubov quasiparticles, which undergo repeated scattering off an ion in the presence of a divergent density of states. We present a quantum-mechanical calculation of the resonant 3He quasiparticle-scattering-limited mobility for negative ions in the anisotropic bulk 3A (A phase) and 3P (polar phase) that is exact when the quasiparticles scatter elastically. We develop a numerical scheme to solve the singular equations for quasiparticle-ion scattering in the A and P phases. Both of these superfluid phases feature a uniaxially symmetric order parameter but distinct topology for the magnitude of the energy gap on the Fermi sphere, i.e., points versus lines of nodes. In particular, the perpetual orbital circulation of Cooper pairs in 3A results in a novel, purely quantum-mechanical intrinsic Magnus effect, which is absent in the polar phase, where Cooper pairs possess no spontaneous orbital angular momentum. This is of interest also for transport properties of heavy-fermion superconductors. We discuss the 3He quasiparticle-ion cross sections, which allow one to account for the mobility data with essentially no free parameters. The calculated mobility thus facilitates an introduction of ``ion spectroscopy'' to extract useful information on fundamental properties of the superfluid state, such as the temperature dependence of the energy gap in 3A.

  18. High Efficiency Spin Flipper for the n3He Experiment

    NASA Astrophysics Data System (ADS)

    Hayes, Christopher; n3He Collaboration

    2015-10-01

    The n3He experiment, constructed on the Fundamental Neutron Physics Beamline (FnPB) at the Spallation Neutron Source, is designed to measure the parity violating (PV) proton asymmetry Ap in the capture reaction n +3 He -->3 H + p + 765 keV The asymmetry has an estimated value Ap ~ - 1 ×10-7 and is directly related to the weak isospin conserved couplings hρ0 and ωρ0 which are of fundamental interest in the verification of the meson exchange model of low energy NN intereactions. Data production for the n3He experiment began in February 2015 and is scheduled to continue thru December 2015 - reaching a statistical sensitivity δAp ~10-8 or better. I will discuss the spin flipper which is designed using the theory of double cosine-theta coils, and capable of flipping neutron spins with an efficiency approaching its maximum value ɛsf = 1 . I will also discuss the theory of Spin Magnetic Resonance (SMR) and how it is employed by the spin flipper to flip 60 Hz pulses of cold neutrons over a range of wavelengths.

  19. Output current variation and polarity effect by electric field and ion-pair non-uniformity inside thimble-type ionization chamber

    NASA Astrophysics Data System (ADS)

    Kim, Jaecheon; Kim, Yong Kyun; Kim, Soon Young; Kim, Jong Kyung

    2007-09-01

    A new analytic approach considering both electric field and ion-pair non-uniformity has been proposed to accurately analyze the design characteristics of an ionization chamber and to interpret measurements. It is commonly assumed that ion-pairs are generated uniformly in the air volume, but such an assumption ignores various source and geometry conditions. The new approach was applied to angular dependence analysis and to polarity effect assessment in an ionization chamber. For the angular dependence analysis, whole, uniform, and non-uniform output currents were calculated as a function of the irradiation angle for an 241Am gamma-ray source. The non-uniform output current proposed in this paper was found to be closer to the measured one. This is because the non-uniform output current takes into account the ion-pair distribution in the air volume as well as the active volume determined by the electric field. For the polarity effect assessment, the amount of field distortion due to potential difference and actual current difference was calculated. Previous methods cannot appropriately estimate the variation of polarity effect because they ignore the influence of the ion-pair distribution. The polarity effect assessment using the non-uniform output current can be more useful for obtaining the practical current difference, because this assessment considers both the variation of active volume and the ion-pair non-uniformity according to source conditions such as the irradiation angle and the distance. It is important to precisely calculate not only the active volume, but also the variation in the ion-pair distribution.

  20. Characterization of radiation beams used to determinate the correction factor for a CyberKnife® unit reference field using ionization chambers

    SciTech Connect

    Aragón-Martínez, Nestor Massillon-JL, Guerda; Gómez-Muñoz, Arnulfo

    2014-11-07

    This paper aimed to characterize a 6 MV x-ray beam from a Varian® iX linear accelerator in order to obtain the correction factors needed by the IAEA/AAPM new formalism{sup 1}. The experiments were performed in a liquid water phantom under different irradiation conditions: a) Calibration of the reference field of 10 cm × 10 cm at 90 cm SSD and 10 cm depth was carried out according to the TRS-398 protocol using three ionization chambers (IC) calibrated in different reference laboratory and b) Measurement of the absorbed dose rate at 70 cm SSD and 10 cm depth in a 10 cm × 10 cm and 5.4 cm × 5.4 cm fields was obtained in order to simulate the CyberKnife® conditions where maximum distance between the source and the detector is equal to 80 cm and the maximum field size is 6 cm diameter. Depending where the IC was calibrated, differences between 0.16% and 2.24% in the absorbed dose rate measured in the 10 cm × 10 cm field at 90 cm SSD were observed, while for the measurements at 70 cm SSD, differences between 1.27% and 3.88% were obtained. For the 5.4 cm × 5.4 cm field, the absorbed dose measured with the three ICs varies between 1.37% and 3.52%. The increase in the difference on the absorbed dose when decreasing the SSD could possibly be associated to scattering radiation generated from the collimators and/or the energy dependence of the ionization chambers to low-energy radiation. The results presented in this work suggest the importance of simulating the CyberKnife® conditions using other linear accelerator for obtaining the correction factors as proposed by the IAEA/AAPM new formalism in order to measure the absorbed dose with acceptable accuracy.

  1. Characterization of radiation beams used to determinate the correction factor for a CyberKnife® unit reference field using ionization chambers

    NASA Astrophysics Data System (ADS)

    Aragón-Martínez, Nestor; Gómez-Muñoz, Arnulfo; Massillon-JL, Guerda

    2014-11-01

    This paper aimed to characterize a 6 MV x-ray beam from a Varian® iX linear accelerator in order to obtain the correction factors needed by the IAEA/AAPM new formalism1. The experiments were performed in a liquid water phantom under different irradiation conditions: a) Calibration of the reference field of 10 cm × 10 cm at 90 cm SSD and 10 cm depth was carried out according to the TRS-398 protocol using three ionization chambers (IC) calibrated in different reference laboratory and b) Measurement of the absorbed dose rate at 70 cm SSD and 10 cm depth in a 10 cm × 10 cm and 5.4 cm × 5.4 cm fields was obtained in order to simulate the CyberKnife® conditions where maximum distance between the source and the detector is equal to 80 cm and the maximum field size is 6 cm diameter. Depending where the IC was calibrated, differences between 0.16% and 2.24% in the absorbed dose rate measured in the 10 cm × 10 cm field at 90 cm SSD were observed, while for the measurements at 70 cm SSD, differences between 1.27% and 3.88% were obtained. For the 5.4 cm × 5.4 cm field, the absorbed dose measured with the three ICs varies between 1.37% and 3.52%. The increase in the difference on the absorbed dose when decreasing the SSD could possibly be associated to scattering radiation generated from the collimators and/or the energy dependence of the ionization chambers to low-energy radiation. The results presented in this work suggest the importance of simulating the CyberKnife® conditions using other linear accelerator for obtaining the correction factors as proposed by the IAEA/AAPM new formalism in order to measure the absorbed dose with acceptable accuracy.

  2. Reference dosimetry at the Australian Synchrotron's imaging and medical beamline using free-air ionization chamber measurements and theoretical predictions of air kerma rate and half value layer

    SciTech Connect

    Crosbie, Jeffrey C.; Rogers, Peter A. W.; Stevenson, Andrew W.; Hall, Christopher J.; Lye, Jessica E.; Nordstroem, Terese; Midgley, Stewart M.; Lewis, Robert A.

    2013-06-15

    Purpose: Novel, preclinical radiotherapy modalities are being developed at synchrotrons around the world, most notably stereotactic synchrotron radiation therapy and microbeam radiotherapy at the European Synchrotron Radiation Facility in Grenoble, France. The imaging and medical beamline (IMBL) at the Australian Synchrotron has recently become available for preclinical radiotherapy and imaging research with clinical trials, a distinct possibility in the coming years. The aim of this present study was to accurately characterize the synchrotron-generated x-ray beam for the purposes of air kerma-based absolute dosimetry. Methods: The authors used a theoretical model of the energy spectrum from the wiggler source and validated this model by comparing the transmission through copper absorbers (0.1-3.0 mm) against real measurements conducted at the beamline. The authors used a low energy free air ionization chamber (LEFAC) from the Australian Radiation Protection and Nuclear Safety Agency and a commercially available free air chamber (ADC-105) for the measurements. The dimensions of these two chambers are different from one another requiring careful consideration of correction factors. Results: Measured and calculated half value layer (HVL) and air kerma rates differed by less than 3% for the LEFAC when the ion chamber readings were corrected for electron energy loss and ion recombination. The agreement between measured and predicted air kerma rates was less satisfactory for the ADC-105 chamber, however. The LEFAC and ADC measurements produced a first half value layer of 0.405 {+-} 0.015 and 0.412 {+-} 0.016 mm Cu, respectively, compared to the theoretical prediction of 0.427 {+-} 0.012 mm Cu. The theoretical model based upon a spectrum calculator derived a mean beam energy of 61.4 keV with a first half value layer of approximately 30 mm in water. Conclusions: The authors showed in this study their ability to verify the predicted air kerma rate and x-ray attenuation

  3. Measurements of miniature ionization chamber currents in the JSI TRIGA Mark II reactor demonstrate the importance of the delayed contribution to the photon field in nuclear reactors

    NASA Astrophysics Data System (ADS)

    Radulović, Vladimir; Fourmentel, Damien; Barbot, Loïc; Villard, Jean-François; Kaiba, Tanja; Gašper, Žerovnik; Snoj, Luka

    2015-12-01

    The characterization of experimental locations of a research nuclear reactor implies the determination of neutron and photon flux levels within, with the best achievable accuracy. In nuclear reactors, photon fluxes are commonly calculated by Monte Carlo simulations but rarely measured on-line. In this context, experiments were conducted with a miniature gas ionization chamber (MIC) based on miniature fission chamber mechanical parts, recently developed by the CEA (French Atomic Energy and Alternative Energies Commission) irradiated in the core of the Jožef Stefan Institute TRIGA Mark II reactor in Ljubljana, Slovenia. The aim of the study was to compare the measured MIC currents with calculated currents based on simulations with the MCNP6 code. A discrepancy of around 50% was observed between the measured and the calculated currents; in the latter taking into consideration only the prompt photon field. Further experimental measurements of MIC currents following reactor SCRAMs (reactor shutdown with rapid insertions of control rods) provide evidence that over 30% of the total measured signal is due to the delayed photon field, originating from fission and activation products, which are untreated in the calculations. In the comparison between the measured and calculated values, these findings imply an overall discrepancy of less than 20% of the total signal which is still unexplained.

  4. Derivation of a formula describing the saturation correction of plane-parallel ionization chambers in pulsed fields with arbitrary repetition rate.

    PubMed

    Karsch, Leonhard

    2016-04-21

    Gas-filled ionization chambers are widely used radiation detectors in radiotherapy. A quantitative description and correction of the recombination effects exists for two cases, for continuous radiation exposure and for pulsed radiation fields with short single pulses. This work gives a derivation of a formula for pulsed beams with arbitrary pulse rate for which the prerequisites of the two existing descriptions are not fulfilled. Furthermore, an extension of the validity of the two known cases is investigated. The temporal evolution of idealized charge density distributions within a plane parallel chamber volume is described for pulsed beams of vanishing pulse duration and arbitrary pulse repetition rate. First, the radiation induced release, movement and collection of the charge carriers without recombination are considered. Then, charge recombination is calculated basing on these simplified charge distributions and the time dependent spatial overlap of positive and negative charge carrier distributions. Finally, a formula for the calculation of the saturation correction factor is derived by calculation and simplification of the first two terms of a Taylor expansion for small recombination. The new formula of saturation correction contains the two existing cases, descriptions for exposure by single pulses and continuous irradiation, as limiting cases. Furthermore, it is possible to determine the pulse rate range for which each of the three descriptions is applicable by comparing the dependencies of the new formula with the two existing cases. As long as the time between two pulses is lower than one third of the collection time of the chamber, the formalism for a continuous exposure can be used. The known description for single pulse irradiation is only valid if the repetition rate is less than 1.2 times the inverse collection time. For all other repetition rates in between the new formula should be used. The experimental determination by Jaffe diagrams can be

  5. WE-EF-207-11: Energy and Depth Response of Thermoluminescent Dosimeters and Ionization Chambers in Water for Kilovoltage X-Ray Beams

    SciTech Connect

    Lawless, M; Palmer, B; DeWerd, L

    2015-06-15

    Purpose: To assess the effects of changes in beam quality on detector response in the kilovoltage energy range by modulating the x-ray tube voltage and the measurement depth in water. Methods: Measurements were performed with TLD-100 and TLD-100H thermoluminescent dosimeters and an A12 farmer-type ionization chamber. To assess the energy response of the detectors, irradiations were performed at a depth of 3 cm in a custom-built thin-window water phantom using the moderately filtered x-ray beams at the UWADCL (20 kVp-250 kVp) and a Co-60 beam.The x-ray beams and detectors were modeled using the EGSnrc Monte Carlo code. The model was validated by simulating dose to the collecting volume of an A12 farmer chamber and comparing it with measured A12 signal as a function of depth. Dose was tallied to each detector and to water for comparison with measurements. Simulations were used to calculate the predicted energy response, which was compared to the measured response of each detector. Dose to each detector and dose to water as a function of depth were also simulated. Results: Detector output per dose to water was found to deviate by up to 15%, 20% and 30% as a function of energy relative to Co-60 for the A12, TLD-100H and TLD-100, respectively. The EGSnrc simulations produced results similar to the measurements for ionization chambers, but discrepancies of up to 30% were observed for TLD-100H. Simulated detector response as a function of depth was found to vary by up to 3%. Conclusion: These results suggest that changes in beam quality in kilovoltage x-ray beams can have a significant impact on detector response. In-water detector response was found to differ from the previously investigated in-air response. Deviations in detector response as a function of depth were less significant, but could potentially cause dosimetric errors if ignored.

  6. Assaying multiple 125I seeds with the well-ionization chamber SourceCheck4π 33005 and a new insert

    PubMed Central

    Ballester, Facundo; Perez-Calatayud, Jose; Vijande, Javier

    2015-01-01

    Purpose To provide a practical solution that can be adopted in clinical routine to fulfill the AAPM-ESTRO recommendations regarding quality assurance of seeds used in prostate permanent brachytherapy. The aim is to design a new insert for the well-ionization chamber SourceCheck4π 33005 (PTW, Germany) that allows evaluating the mean air-kerma strength of up to ten 125I seeds with one single measurement instead of measuring each seed individually. Material and methods The material required is: a) the SourceCheck4π 33005 well-ionization chamber provided with a PTW insert to measure the air-kerma strength S K of one single seed at a time; b) a newly designed insert that accommodates ten seeds in one column, which allows measuring the mean S K of the ten seeds in one single measurement; and c) a container with ten seeds from the same batch and class of the seeds used for the patient implant, and a set of nine non-radioactive seeds. The new insert is characterized by determining its calibration coefficient, used to convert the reading of the well-chamber when ten seeds are measured to their mean S K. The proposed method is validated by comparing the mean S K of the ten seeds obtained from the new insert with the individual measurement of S K of each seed, evaluated with the PTW insert. Results The ratio between the calibration coefficient of the new insert and the calibration coefficient of the PTW insert for the SourceCheck4π 33005 is 1.135 ± 0.007 (k = 1). The mean S K of a set of ten seeds evaluated with this new system is in agreement with the mean value obtained from measuring independently the S K of each seed. Conclusions The new insert and procedure allow evaluating the mean S K of ten seeds prior to the implant in a single measurement. The method is faster and more efficient from radiation protection point of view than measuring the individual S K of each seed. PMID:26816507

  7. Nuclear Ordered Phases of Solid 3He in Silver Sinters

    NASA Astrophysics Data System (ADS)

    Schuberth, Erwin A.; Kath, Matthias; Bago, Simone

    2006-09-01

    To determine the exact spin structure of the nuclear magnetic ordered phases of solid 3He, the U2D2 low field and the high field phases above 0.4 T, a European Research and Training Network for neutron scattering from the ordered solid was established which consisted of a collaboration with the Hahn Meitner Institute, Berlin, and other European and US groups. For this experiment it is crucial to grow a single crystal within the sinter needed for cooling the solid to temperatures of the order of 500 μK and to keep it cold long enough to measure a magnetic neutron diffraction. The sinter is also necessary to absorb the major part (> 90%) of the heat generated by the neutron capture and decay reaction of the 3He nucleus. In this work we studied the growth of crystals in Ag sinters of different pore sizes and with different growth speeds to find an optimal way to obtain single crystalline samples, or at least samples with only a few grains. We used SQUID magnetometry and NMR to measure the magnetization in the ordered phases. They were indicated by the known drop of the intensity, both in the NMR signal and in the dc magnetization, for the U2D2 phase, and by an increase of about 30% for the high field phase. The best results for cooling were obtained with sinters made from 700 Å "Japanese powder" with a packing fraction of 50% which were annealed at 130 °C after sintering and then had a calculated particle size of about 4200 Å. In the dc magnetization we found a paramagnetic surface contribution from a few monolayers of 3He down to 500 μK in addition to the bulk magnetization.

  8. Poster — Thur Eve — 21: Off-axis dose perturbation effects in water in a 5 × 5 cm{sup 2} 18 MV photon beam for the PTW microLion and Exradin A1SL ionization chambers

    SciTech Connect

    O'Grady, K; Davis, S D; Papaconstadopoulos, P; Seuntjens, J

    2014-08-15

    A PTW microLion liquid ionization chamber and an Exradin A1SL air-filled ionization chamber have been modeled using the egs-chamber user code of the EGSnrc system to determine their perturbation effects in water in a 5 × 5 cm{sup 2} 18 MV photon beam. A model of the Varian CL21EX linear accelerator was constructed using the BEAMnrc Monte Carlo code, and was validated by comparing measured PDDs and profiles from the microLion and A1SL chambers to calculated results that included chamber models. Measured PDDs for a 5 × 5 cm{sup 2} field for the microLion chamber agreed with calculations to within 1.5% beyond a depth of 0.5 cm, and the A1SL PDDs agreed within 1.0% beyond 1.0 cm. Measured and calculated profiles at 10 cm depth agreed within 1.0% for both chambers inside the field, and within 4.0% near the field edge. Local percent differences increased up to 15% at 4 cm outside the field. The ratio of dose to water in the absence of the chamber relative to dose in the chamber's active volume as a function of off-axis distance was calculated using the egs-chamber correlated sampling technique. The dose ratio was nearly constant inside the field and consistent with the stopping power ratios of water to detector material, but varied up to 3.3% near the field edge and 5.2% at 4 cm outside the field. Once these perturbation effects are fully characterized for more field sizes and detectors, they could be applied to clinical water tank measurements for improved dosimetric accuracy.

  9. Fermion Monte Carlo Calculations on Liquid-3He

    SciTech Connect

    Kalos, M H; Colletti, L; Pederiva, F

    2004-03-16

    Methods and results for calculations of the ground state energy of the bulk system of {sup 3}He atoms are discussed. Results are encouraging: they believe that they demonstrate that their methods offer a solution of the ''fermion sign problem'' and the possibility of direct computation of many-fermion systems with no uncontrolled approximations. Nevertheless, the method is still rather inefficient compared with variational or fixed-node approximate methods. There appears to be a significant populations size effect. The situation is improved by the inclusion of ''Second Stage Importance Sampling'' and of ''Acceptance/Rejection'' adapted to their needs.

  10. 3He Spin-Dependent Cross Sections and Sum Rules

    SciTech Connect

    Slifer, Karl; Amaryan, Moscov; Amaryan, Moskov; Auerbach, Leonard; Averett, Todd; Berthot, J.; Bertin, Pierre; Bertozzi, William; Black, Tim; Brash, Edward; Brown, D.; Burtin, Etienne; Calarco, John; Cates, Gordon; Chai, Zhengwei; Chen, Jian-Ping; Choi, Seonho; Chudakov, Eugene; Ciofi, Claudio; Cisbani, Evaristo; De Jager, Cornelis; Deur, Alexandre; DiSalvo, R.; Dieterich, Sonja; Djawotho, Pibero; Finn, John; Fissum, Kevin; Fonvieille, Helene; Frullani, Salvatore; Gao, Haiyan; Gao, Juncai; Garibaldi, Franco; Gasparian, Ashot; Gilad, Shalev; Gilman, Ronald; Glamazdin, Oleksandr; Glashausser, Charles; Glockle, W.; Golak, J.; Goldberg, Emma; Gomez, Javier; Gorbenko, Viktor; Hansen, Jens-Ole; Hersman, F.; Holmes, Richard; Huber, Garth; Hughes, Emlyn; Humensky, Thomas; Incerti, Sebastien; Iodice, Mauro; Jensen, S.; Jiang, Xiaodong; Jones, C.; Jones, G.; Jones, Mark; Jutier, Christophe; Kamada, H.; Ketikyan, Armen; Kominis, Ioannis; Korsch, Wolfgang; Kramer, Kevin; Kumar, Krishna; Kumbartzki, Gerfried; Kuss, Michael; Lakuriqi, Enkeleida; Laveissiere, Geraud; LeRose, John; Liang, Meihua; Liyanage, Nilanga; Lolos, George; Malov, Sergey; Marroncle, Jacques; McCormick, Kathy; McKeown, Robert; Meziani, Zein-Eddine; Michaels, Robert; Mitchell, Joseph; Nogga, Andreas; Pace, Emanuele; Papandreou, Zisis; Pavlin, Tina; Petratos, Gerassimos; Pripstein, David; Prout, David; Ransome, Ronald; Roblin, Yves; Rowntree, David; Rvachev, Marat; Sabatie, Franck; Saha, Arunava; Salme, Giovanni; SCOPETTA, S.; Skibinski, R.; Souder, Paul; Saito, Teijiro; Strauch, Steffen; Suleiman, Riad; Takahashi, Kazunori; Todor, Luminita; Tsubota, Hiroaki; Ueno, Hiroaki; Urciuoli, Guido; van der Meer, Rob; Vernin, Pascal; Voskanyan, Hakob; Witala, Henryk; Wojtsekhowski, Bogdan; Xiong, Feng; Xu, Wang; Yang, Jae-Choon; Zhang, Bin; Zolnierczuk, Piotr

    2008-07-01

    We present a measurement of the spin-dependent cross sections for the \\vec{^3He}(\\vec{e},e')X} reaction in the quasielastic and resonance regions at four-momentum transfer 0.1 < Q^2< 0.9 GeV^2. The spin-structure functions have been extracted and used to evaluate the nuclear Burkhardt--Cottingham and extended GDH sum rules for the first time. Impulse approximation and exact three-body Faddeev calculations are also compared to the data in the quasielastic region.

  11. High-pressure /sup 3/He gas scintillation neutron spectrometer

    SciTech Connect

    Derzon, M.S.; Slaughter, D.R.; Prussin, S.G.

    1985-10-01

    A high-pressure, /sup 3/He-Xe gas scintillation spectrometer has been developed for neutron spectroscopy on D-D fusion plasmas. The spectrometer exhibits an energy resolution of (121 +- 20 keV) keV (FWHM) at 2.5 MeV and an efficiency of (1.9 +- 0.4) x 10/sup -3/ (n/cm/sup 2/)/sup -1/. The contribution to the resolution (FWHM) from counting statistics is only (22 +- 3 keV) and the remainder is due predominantly to the variation of light collection efficiency with location of neutron events within the active volume of the detector.

  12. Hard Photodisintegration of Proton Pairs in {sup 3}He

    SciTech Connect

    Piasetzky, Eli; Pomerantz, Ishay; Higinbotham, D.; Strauch, S.; Gilman, R.

    2008-10-13

    Hard deuteron photodisintegration has been investigated for 20 years, as its cross section follows the constituent counting rule and it provides insight into the interplay between hadronic and quark-gluon degrees of freedom in high-momentum transfer exclusive reactions. We have now measured for the first time hard pp-pair disintegration in the reaction {gamma}{sup 3}He{yields}pp+n, using kinematics corresponding to a spectator neutron. Cross sections were measured for 90 deg. c.m. at 8 beam energies, from 0.8 to 4.7 GeV. Preliminary results will be presented and compared to the hard deuteron photodisintegration data.

  13. Quasi-elastic electron scattering from polarized 3He

    SciTech Connect

    H. J. Bulten; Ricardo Alarcon; Th. Bauer; D. Boersma; T. Botto; J. F. J. van den Brand; L. van Buuren; Rolf Ent; M. Ferro-Luzzi; D. Geurts; M. Harvey; Peter Heimberg; D. Highinbotham; Kees de Jager; Blaine Norum; I. Passchier; H. R. Poolman; M. van den Putte; E. Six; J. Steijger; D. Szczerba; H. de Vries

    1997-08-01

    Quasi-elastic electron scattering may provide precise information on the S and the D-wave parts of the {sup 3}He ground-state wave function, the neutron form factors, and the role of spin-dependent reaction mechanism effects. An experiment is being performed at the AmPS storage ring at NIKHEF (Amsterdam, the Netherlands), where polarized electrons (up to 900 MeV) are used in combination with large acceptance electron and hadron detectors. Preliminary results from data at four-momentum transfer squared Q{sup 2} = 0.15 GeV{sup 2} are presented.

  14. 3He spin-dependent cross sections and sum rules.

    PubMed

    Slifer, K; Amarian, M; Auerbach, L; Averett, T; Berthot, J; Bertin, P; Bertozzi, B; Black, T; Brash, E; Brown, D; Burtin, E; Calarco, J; Cates, G; Chai, Z; Chen, J-P; Choi, Seonho; Chudakov, E; Ciofi Degli Atti, C; Cisbani, E; de Jager, C W; Deur, A; DiSalvo, R; Dieterich, S; Djawotho, P; Finn, M; Fissum, K; Fonvieille, H; Frullani, S; Gao, H; Gao, J; Garibaldi, F; Gasparian, A; Gilad, S; Gilman, R; Glamazdin, A; Glashausser, C; Glöckle, W; Golak, J; Goldberg, E; Gomez, J; Gorbenko, V; Hansen, J-O; Hersman, B; Holmes, R; Huber, G M; Hughes, E; Humensky, B; Incerti, S; Iodice, M; Jensen, S; Jiang, X; Jones, C; Jones, G; Jones, M; Jutier, C; Kamada, H; Ketikyan, A; Kominis, I; Korsch, W; Kramer, K; Kumar, K; Kumbartzki, G; Kuss, M; Lakuriqi, E; Laveissiere, G; Lerose, J J; Liang, M; Liyanage, N; Lolos, G; Malov, S; Marroncle, J; McCormick, K; McKeown, R D; Meziani, Z-E; Michaels, R; Mitchell, J; Nogga, A; Pace, E; Papandreou, Z; Pavlin, T; Petratos, G G; Pripstein, D; Prout, D; Ransome, R; Roblin, Y; Rowntree, D; Rvachev, M; Sabatié, F; Saha, A; Salmè, G; Scopetta, S; Skibiński, R; Souder, P; Saito, T; Strauch, S; Suleiman, R; Takahashi, K; Teijiro, S; Todor, L; Tsubota, H; Ueno, H; Urciuoli, G; Van der Meer, R; Vernin, P; Voskanian, H; Witała, H; Wojtsekhowski, B; Xiong, F; Xu, W; Yang, J-C; Zhang, B; Zolnierczuk, P

    2008-07-11

    We present a measurement of the spin-dependent cross sections for the 3He over -->(e over -->,e')X reaction in the quasielastic and resonance regions at a four-momentum transfer 0.1< or =Q2< or =0.9 GeV2. The spin-structure functions have been extracted and used to evaluate the nuclear Burkhardt-Cottingham and extended Gerasimov-Drell-Hearn sum rules for the first time. The data are also compared to an impulse approximation calculation and an exact three-body Faddeev calculation in the quasielastic region.

  15. Textural domain walls in superfluid 3He-B

    NASA Astrophysics Data System (ADS)

    Mizushima, Takeshi

    Owing to the richness of symmetry, the superfluid 3He serves as a rich repository of topological quantum phenomena. This includes the emergence of surface Majorana fermions and their quantum mass acquisition at the topological critical point. Furthermore, the marriage of the prototype topological superfluid with nanofabrication techniques brings about a rich variety of spontaneous symmetry breaking, such as the formation of the stripe order and nontrivial domain walls. In this work, we examine the possible formation of textural domain walls in the superfluid 3He-B confined to a thin slab with a sub-micron thickness. When an applied magnetic field is much higher than the dipolar field, two nearly degenerate ground states appear, which are characterized by the Ising order associated with the spontaneous breaking of a magnetic order-two symmetry, lcirc;z = + 1 and - 1 . We here discuss the structure of the textural domain wall formed by the spatial modulation of the Ising order, such as low-lying quasiparticle excitations and spontaneous spin current. We also report bosonic modes bound to the textural domain wall.

  16. Effective theory of 3H and 3He

    NASA Astrophysics Data System (ADS)

    König, Sebastian; Grießhammer, Harald W.; Hammer, H.-W.; van Kolck, U.

    2016-06-01

    We present a new perturbative expansion for pionless effective field theory with Coulomb interactions in which at leading order (LO) the spin-singlet nucleon-nucleon channels are taken in the unitarity limit. Presenting results up to next-to-leading order for the Phillips line and the neutron-deuteron doublet-channel phase shift, we find that a perturbative expansion in the inverse {}1{S}0 scattering lengths converges rapidly. Using a new systematic treatment of the proton-proton sector that isolates the divergence due to one-photon exchange, we renormalize the corresponding contribution to the {}3{{H}} -{}3{He} binding energy splitting and demonstrate that the Coulomb force in pionless EFT is a completely perturbative effect in the trinucleon bound-state regime. In our new expansion, the LO is exactly isospin-symmetric. At next-to-leading order, we include isospin breaking via the Coulomb force and two-body scattering lengths, and find for the energy splitting {({E}B{(}3{He})-{E}B{(}3{{H}}))}{NLO}\\quad =(-0.86+/- 0.17)\\quad {MeV}.

  17. The 3H-3He Charge Radii Difference

    SciTech Connect

    Myers, Luke S.; Arrington, John R.; Higinbotham, Douglas W.

    2016-03-01

    The upcoming E12-14-009 [1] experiment at Jefferson Lab will determine the ratio of the electric form factors for the A=3 mirror nuclei 3He and 3H. The measurement will use a 1.1 GeV electron beam, a special collimator plate to allow for simultaneous optics measurements, and the low-activity tritium target being prepared for Jefferson Lab. By observing the dependence of the form factor ratio as a function of Q2 over 0.05–0.09 GeV2, the dependence of the radii extraction on the shape of the form factors is minimized. As a result, we anticipate the uncertainty of the extracted charge radii difference to be 0.03 fm, a reduction of 70% from the current measurement. Using precise measurements of the 3He charge radius from isotopic shift or μHe measurements [2–4], we can deduce the absolute 3H charge radius. The results will provide a direct comparison to recent calculations of the charge radii.

  18. 3He film flow on a round rim beaker

    NASA Astrophysics Data System (ADS)

    Steel, S. C.; Harrison, J. P.; Zawadzki, P.; Sachrajda, A.

    1994-06-01

    The superfluid properties of thin (100 150 nm) of3He were investigated by measuring the rate at which a beaker of liquid3He emptied itself through the adsorbed film, with the film thickness δ decreasing as the level dropped. A beaker rim with a semicircular cross-section was used to provide a well defined geometry and to avoid the effects of small scratches that may have affected earlier experiments. The film thicknesses were determined by Atkins' oscillaton measurements of4He films on the same surface. The superfluid transition temperature in the film T {/c F } was suppressed below the bulk value T {/c B }, and was close to being described by 2δ/ξ( T {/c F }) = π, as expected for A-phase. The critical current density was more than an order of magnitude smaller than expected for pair-breaking. When a4He monolayer was adsorbed on the substrate, there was no suppresson of T {/c F }.

  19. Effect of Aerogel Anisotropy in Superfluid 3He-A

    NASA Astrophysics Data System (ADS)

    Zimmerman, A. M.; Li, J. I. A.; Pollanen, J.; Collett, C. A.; Gannon, W. J.; Halperin, W. P.

    2014-03-01

    Two theories have been advanced to describe the effects of anisotropic impurity introduced by stretched silica aerogel on the orientation of the orbital angular momentum l& circ; in superfluid 3He-A. These theories disagree on whether the anisotropy will orient l& circ; perpendicular[2] or parallel[3] to the strain axis. In order to examine this question we have produced and characterized a homogeneous aerogel sample with uniaxial anisotropy introduced during growth, corresponding to stretching of the aerogel. These samples have been shown to stabilize two new chiral states;[4] the higher temperature state being the subject of the present study. Using pulsed NMR we have performed experiments on 3He-A imbibed in this sample in two orientations: strain parallel and perpendicular to the applied magnetic field. From the NMR frequency shifts as a function of tip angle and temperature, we find that the angular momentum l& circ; is oriented along the strain axis, providing evidence for the theory advanced by Sauls. This work was supported by the National Science Foundation, DMR-1103625.

  20. Pion absorption on 3He at low energies

    NASA Astrophysics Data System (ADS)

    Hahn, H.; Altman, A.; Ashery, D.; Gefen, G.; Gill, D. R.; Johnson, R. R.; Levy-Nathansohn, R.; Moinester, M. A.; Sevior, M.; Trelle, R. P.

    1996-03-01

    The reactions 3He(π+,pp)p and 3He(π-,pn)n were studied at 37.0 MeV by coincidence detection of two nucleons. The differential cross sections were separated to two-nucleon (σ2N), three-nucleon (σ3N), and final-state interaction (σFSI) components. For π+, the σ2N angular distribution is symmetric about 90°, and the total cross section is 1.5 times the cross section measured for d(π+,pp). For π-, the angular distribution is asymmetric (backward peaked). The asymmetry increases with decreasing energy, indicating increasing pion s-wave contribution at lower energies. The fraction of the cross section induced by s-wave pions as calculated by a partial wave amplitude analysis is 13%. The measured total cross sections are σ2N(π-)=0.85+/-0.08 mb and σ2N(π+)=7.9+/-0.5 mb; σ3N(π-)=1.6+/-0.7 mb and σ3N(π+)=1.3+/-0.3 mb. A new evaluation of σ3N at Tπ=62.5 and 82.8 MeV is given, using data from an earlier experiment. The cross sections leading to the two-nucleon final-state interaction at Tπ=37.0 MeV are also estimated.

  1. Interaction of Hydrogen Atoms with Helium Films: Sticking Probabilities for H on 3He and 4He, and the Binding Energy of H on 3He

    NASA Astrophysics Data System (ADS)

    Jochemsen, R.; Morrow, M.; Berlinsky, A. J.; Hardy, W. N.

    1981-09-01

    Magnetic resonance at 1420 MHz in zero magnetic field and for 0.063He, the rate constant for recombination and the frequency shift for H on 3He, and the sticking probability for H on 3He and 4He. The binding energy for H on liquid 3He is found to be 0.42+/-0.05 K, and the sticking probabilities are 0.035 for H on 4He and 0.016 for H on 3He.

  2. Chiral phases of superfluid 3He in an anisotropic medium

    NASA Astrophysics Data System (ADS)

    Sauls, J. A.

    2013-12-01

    Recent advances in the fabrication and characterization of anisotropic silica aerogels with exceptional homogeneity provide new insight into the nature of unconventional pairing in disordered anisotropic media. I report theoretical analysis and predictions for the equilibrium phases of superfluid 3He infused into a low-density, homogeneous uniaxial aerogel. Ginzburg-Landau (GL) theory for a class of equal-spin-pairing (ESP) states in a medium with uniaxial anisotropy is developed and used to analyze recent experiments on uniaxially strained aerogels. For 3He in an axially “stretched” aerogel, GL theory predicts a transition from normal liquid into a chiral Anderson-Morel phase at Tc1 in which the chirality axis l̂ is aligned along the strain axis. This orbitally aligned state is protected from random fluctuations in the anisotropy direction, has a positive nuclear magnetic resonance (NMR) frequency shift, a sharp NMR resonance line, and is identified with the high-temperature ESP-1 phase of superfluid 3He in axially stretched aerogel. A second transition into a biaxial phase is predicted to onset at a slightly lower temperature Tc2

  3. Direct energy conversion system for D(3)-He fusion

    NASA Astrophysics Data System (ADS)

    Tomita, Y.; Shu, L. Y.; Momota, H.

    1993-11-01

    A novel and highly efficient direct energy conversion system is proposed for utilizing D(3)-He fueled fusion. In order to convert kinetic energy of ions, we applied a pair of direct energy conversion systems each of which has a cusp-type DEC and a traveling wave DEC (TWDEC). In a cusp-type DEC, electrons are separated from the escaping ions at the first line-cusp and the energy of thermal ion components is converted at the second cusp DEC. The fusion protons go through the cusp-type DEC and arrive at the TWDEC, which principle is similar to 'LINAC'. The energy of fusion protons is recovered to electricity with an efficiency of more than 70%. These DEC's bring about the high efficient fusion plant.

  4. Perspectives of hyperpolarized noble gas MRI beyond 3He

    NASA Astrophysics Data System (ADS)

    Lilburn, David M. L.; Pavlovskaya, Galina E.; Meersmann, Thomas

    2013-04-01

    Nuclear Magnetic Resonance (NMR) studies with hyperpolarized (hp) noble gases are at an exciting interface between physics, chemistry, materials science and biomedical sciences. This paper intends to provide a brief overview and outlook of magnetic resonance imaging (MRI) with hp noble gases other than hp 3He. A particular focus are the many intriguing experiments with 129Xe, some of which have already matured to useful MRI protocols, while others display high potential for future MRI applications. Quite naturally for MRI applications the major usage so far has been for biomedical research but perspectives for engineering and materials science studies are also provided. In addition, the prospects for surface sensitive contrast with hp 83Kr MRI is discussed.

  5. APT {sup 3}He target/blanket. Topical report

    SciTech Connect

    1995-03-01

    The {sup 3}He target/blanket (T/B) preconceptual design for the 3/8-Goal facility is based on a 1000-MeV, 200-mA accelerator to produce a high-intensity proton beam that is expanded and then strikes one of two T/B modules. Each module consists of a centralized neutron source made of tungsten and lead, a proton beam backstop region made of zirconium and lead, and a moderator made of D{sub 2}O. Helium-3 gas is circulated through the neutron source region and the blanket to create tritium through neutron capture. The gas is continually processed to extract the tritium with an online separation process.

  6. Alpha Backgrounds in the SNO ^3He Proportional Counter Array

    NASA Astrophysics Data System (ADS)

    Stonehill, Laura

    2006-04-01

    The Sudbury Neutrino Observatory (SNO) has recently deployed an array of proportional counters known as Neutral Current Detectors (NCDs) to detect thermalized neutrons via the ^3He(n,p)^3H reaction. The primary physics background to the neutron-capture signal is alpha particle emission from uranium- and thorium-chain decays in the NCD walls. The expected capture rate of neutrons from the neutral-current neutrino reaction on deuterium is three per day and the intrinsic alpha background rate is approximately 250 alphas per day. Fewer than 10% of these alphas fall into the energy range where neutron-capture signals occur, and a substantial number of these can be eliminated by pulse-shape analysis. This talk will focus on measurements of the alpha backgrounds in the NCDs and the extent to which these alphas contaminate the neutron-capture signal region.

  7. Realization of administration unit for 3He with gas recycling

    NASA Astrophysics Data System (ADS)

    Güldner, M.; Becker, S.; Friesenecker, A.; Gast, K. K.; Heil, W.; Karpuk, S.; Otten, E. W.; Rivoire, J.; Salhi, Z.; Scholz, A.; Schreiber, L. M.; Terekhov, M.; Weiss, P.; Wolf, U.; Zentel, J.

    2011-06-01

    Hyperpolarized (HP) noble gases (3He,129Xe) are used for MR-imaging of the lung. In the majority of case the HP gas is filled in Tedlarbags and directly inhaled by the patients. Starting from an earlier pilot device, an administration unit was built respectively to the Medical Devices Law to administer patients HP noble gas boli in defined quantities and at a predefined time during inspiration with high reproducibility and reliability without reducing MR-quality. The patient's airflows are monitored and recorded. It is possible to use gas admixtures, measure the polarization on-line and collect the exhaled gas for later recycling. The first images with healthy volunteers were taken with this setup in a clinical study. Current results will be presented.

  8. Electrodisintegration of 3He below and above deuteron breakup threshold

    SciTech Connect

    Marcucci, L. E.; Viviani, M.; Schiavilla, R.; Kievsky, A.; Rosati, S.

    2005-02-01

    Recent advances in the study of electrodisintegration of 3He are presented and discussed. The pair-correlated hyperspherical harmonics method is used to calculate the initial and final state wave functions, with a realistic Hamiltonian consisting of the Argonne v18 two-nucleon and Urbana IX three-nucleon interactions. The model for the nuclear current and charge operators retains one- and many-body contributions. Particular attention is made in the construction of the two-body current operators arising from the momentum-dependent part of the two-nucleon interaction. Three-body current operators are also included so that the full current operator is strictly conserved. The present model for the nuclear current operator is tested comparing theoretical predictions and experimental data of pd radiative capture cross section and spin observables.

  9. {sup 3}He target for Hall C at CEBAF

    SciTech Connect

    Zeidman, B.; Zeuli, A.

    1995-08-01

    A major fraction of the physics program for Hall C involves scattering from cryogenic targets of the lightest nuclei, i.e. H, D, and {sup 3,4}He. Argonne is constructing the He target that will consist of a 4cm cylinder, operating at a pressure of 10 atmospheres and a temperature of {approximately}5.2 degrees Kelvin. CEBAF is currently constructing a cryo-target system for liquid H and D cells and the cooled, pressurized helium targets. The He target system includes cell loop, the He supply systems, and the additional equipment needed to ensure minimum loss of {sup 3}He in the event of target rupture. Some of the major components have been completed, while the balance of the system will be ready for installation this fiscal year.

  10. Are high 3He/4He ratios in oceanic basalts an indicator of deep-mantle plume components?

    USGS Publications Warehouse

    Meibom, A.; Anderson, D.L.; Sleep, Norman H.; Frei, R.; Chamberlain, C.P.; Hren, M.T.; Wooden, J.L.

    2003-01-01

    The existence of a primordial, undegassed lower mantle reservoir characterized by high concentration of 3He and high 3He/4He ratios is a cornerstone assumption in modern geochemistry. It has become standard practice to interpret high 3He/4He ratios in oceanic basalts as a signature of deep-rooted plumes. The unfiltered He isotope data set for oceanic spreading centers displays a wide, nearly Gaussian, distribution qualitatively similar to the Os isotope (187Os/188 Os) distribution of mantle-derived Os-rich alloys. We propose that both distributions are produced by shallow mantle processes involving mixing between different proportions of recycled, variably aged radiogenic and unradiogenic domains under varying degrees of partial melting. In the case of the Re-Os isotopic system, radiogenic mid-ocean ridge basalt (MORB)-rich and unradiogenic (depleted mantle residue) endmembers are constantly produced during partial melting events. In the case of the (U+Th)-He isotope system, effective capture of He-rich bubbles during growth of phenocryst olivine in crystallizing magma chambers provides one mechanism for 'freezing in' unradiogenic (i.e. high 3He/4He) He isotope ratios, while the higher than chondritic (U+Th)/He elemental ratio in the evolving and partially degassed MORB melt provides the radiogenic (i.e. low 3He/4He) endmember. If this scenario is correct, the use of He isotopic signatures as a fingerprint of plume components in oceanic basalts is not justified. Published by Elsevier Science B.V.

  11. Neutron multiplicity ,easurements With 3He alternative: Straw neutron detectors

    DOE PAGES

    Mukhopadhyay, Sanjoy; Wolff, Ronald S.; Meade, John A.; ...

    2015-01-27

    Counting neutrons emitted by special nuclear material (SNM) and differentiating them from the background neutrons of various origins is the most effective passive means of detecting SNM. Unfortunately, neutron detection, counting, and partitioning in a maritime environment are complex due to the presence of high-multiplicity spallation neutrons (commonly known as “ship effect”) and to the complicated nature of the neutron scattering in that environment. In this study, a prototype neutron detector was built using 10B as the converter in a special form factor called “straws” that would address the above problems by looking into the details of multiplicity distributions ofmore » neutrons originating from a fissioning source. This paper describes the straw neutron multiplicity counter (NMC) and assesses the performance with those of a commercially available fission meter. The prototype straw neutron detector provides a large-area, efficient, lightweight, more granular (than fission meter) neutron-responsive detection surface (to facilitate imaging) to enhance the ease of application of fission meters. Presented here are the results of preliminary investigations, modeling, and engineering considerations leading to the construction of this prototype. This design is capable of multiplicity and Feynman variance measurements. This prototype may lead to a near-term solution to the crisis that has arisen from the global scarcity of 3He by offering a viable alternative to fission meters. This paper describes the work performed during a 2-year site-directed research and development (SDRD) project that incorporated straw detectors for neutron multiplicity counting. The NMC is a two-panel detector system. We used 10B (in the form of enriched boron carbide: 10B4C) for neutron detection instead of 3He. In the first year, the project worked with a panel of straw neutron detectors, investigated its characteristics, and developed a data acquisition (DAQ) system to collect

  12. Hard photodisintegration of 3He into a p d pair

    NASA Astrophysics Data System (ADS)

    Maheswari, Dhiraj; Sargsian, Misak M.

    2017-02-01

    The recent measurements of high energy photodisintegration of a 3He nucleus to a p d pair at 90∘ center of mass demonstrated an energy scaling consistent with the quark counting rule with an unprecedentedly large exponent of s-17. To understand the underlying mechanism of this process, we extended the theoretical formalism of the hard rescattering mechanism (HRM) to calculate the γ 3He→p d reaction. In HRM the incoming high energy photon strikes a quark from one of the nucleons in the target which subsequently undergoes hard rescattering with the quarks from the other nucleons, generating a hard two-body system in the final state of the reaction. Within the HRM we derived the parameter-free expression for the differential cross section of the reaction, which is expressed through the 3He→p d transition spectral function, the cross section of hard p d →p d scattering, and the effective charge of the quarks being interchanged during the hard rescattering process. The numerical estimates of all these factors resulted in the magnitude of the cross section, which is surprisingly in good agreement with the data.

  13. Andreev reflection in rotating superfluid {sup 3}He-B

    SciTech Connect

    Eltsov, V. B.; Hosio, J. J.; Krusius, M. Mäkinen, J. T.

    2014-12-15

    Andreev reflection of quasiparticle excitations from quantized line vortices is reviewed in the isotropic B phase of superfluid {sup 3}He in the temperature regime of ballistic quasiparticle transport at T ≤ 0.20T{sub c}. The reflection from an array of rectilinear vortices in solid-body rotation is measured with a quasiparticle beam illuminating the array mainly in the orientation along the rotation axis. The result is in agreement with the calculated Andreev reflection. The Andreev signal is also used to analyze the spin-down of the superfluid component after a sudden impulsive stop of rotation from an equilibrium vortex state. In a measuring setup where the rotating cylinder has a rough bottom surface, annihilation of the vortices proceeds via a leading rapid turbulent burst followed by a trailing slow laminar decay, from which the mutual friction dissipation can be determined. In contrast to the currently accepted theory, it is found to have a finite value in the zero-temperature limit: α(T→0) = (5 ± 0.5) × 10{sup −4}.

  14. Optical interferometry in superfluid {sup 3}He-B

    SciTech Connect

    Alles, H.; Ruutu, J.P.; Babkin, A.V.; Hakonen, P.J.; Sonin, E.B.

    1996-03-01

    The authors report interferometric measurements in 0.1...1 mm thick films of superfluid {sup 3}He-B. The menisci of three different rotational states of the superfluid were observed and analyzed theoretically using two-fluid hydrodynamics: These are (i) the equilibrium vortex state in which the superfluid and the normal components corotate (solid body rotation), (ii) the vortex-free state (the Landau state), in which only the normal component rotates, and (iii) the quasistationary vortex state in which only the superfluid fraction rotates (pure superfluid rotation). The Landua state manifested itself by a reduced parabolic meniscus at rotation speeds below the critical angular velocity {Omega}{sub c}{approx_lt} 0.2 rad/s for vortex formation. Transition from the Landua state to the equilibrium vortex state yielded a sudden deepening of the meniscus when {Omega}{sub c} was exceeded. After a rapid halt of the cryostat, the authors observed a novel meniscus which was produced by the superfluid rotation while the normal component was at rest. The enhanced depth of this meniscus is governed by the reactive mutual friction parameter B{prime}. By employing laser light, both for imaging and for thermomechanical excitation, the authors measured the response of a thin superfluid layer to a heat pulse and analyzed it within the theory of two fluid hydrodynamics. The data were employed, using the dispersion relation for thin film oscillations, to deduce the second viscosity coefficient {zeta}{sub 3} close to T{sub c}.

  15. Transfer Excitation Processes Observed in N3+-He and O3+-He Collisions at Elab = 33 eV

    NASA Astrophysics Data System (ADS)

    Itoh, Yoh

    2016-09-01

    We measured the relative state-selective differential cross sections (DCSs) for one-electron capture reactions using a crossed-beam apparatus. The scattering angle θlab studied in the laboratory frame ranged from -3.0 to 22° and the laboratory collision energy Elab was 33 eV. Only the transfer excitation processes, i.e., the electron capture reactions with the simultaneous excitation of the projectile, were observed. The DCSs were determined for the following reactions: N3+ (1s2 2s2 1S) + He (1s2 1S) → N2+ (1s2 2s2p2 2D) + He+ (1s 2S) + 10.3 eV, O3+ (1s2 2s2 2p 2P) + He (1s2 1S) → O2+ (1s2 2s 2p3 3P) + He+ (1s 2S) + 12.7 eV, and O3+ (1s2 2s2 2p 2P) + He (1s2 1S) → O2+ (1s2 2s 2p3 3D) + He+ (1s 2S) + 15.5 eV. In the N3+-He system, the DCSs for the reaction are zero at the center-of-mass angle θcm = 0 and show a peak at a certain angle and a shoulder at a larger angle. In the O3+-He system, the DCSs are again zero at θcm = 0. The capture process to the O2+ (1s2 2s 2p3 3P) state is mainly observed at smaller scattering angles, and the reaction to the O2+ (1s2 2s 2p3 3D) state becomes dominant with increasing scattering angle. A classical trajectory analysis within the two-state approximation based on the ab initio potentials for (NHe)3+ revealed that the transfer excitation of a two-electron process takes place through a single crossing of the relevant potentials.

  16. Comment on "Deep mixing of 3He: reconciling Big Bang and stellar nucleosynthesis".

    PubMed

    Balser, Dana S; Rood, Robert T; Bania, T M

    2007-08-31

    Eggleton et al. (Reports, 8 December 2006, p. 1580) reported on a deep-mixing mechanism in low-mass stars caused by a Rayleigh-Taylor instability that destroys all of the helium isotope 3He produced during the star's lifetime. Observations of 3He in planetary nebulae, however, indicate that some stars produce prodigious amounts of 3He. This is inconsistent with the claim that all low-mass stars should destroy 3He.

  17. Temporal Variability in the Accretion Rate of Interplanetary Dust Using (3)He as a Tracer

    NASA Technical Reports Server (NTRS)

    Farley, K. A.

    2005-01-01

    The research supported by this grant falls under three topics: 1) Weekly Interplanetary Dust Sampling via (3)He; 2) Extraterrestrial (3)He at Major Impact Boundaries; 3) Completing a Moderately-High Resolution Record of Extraterrestrial (3)He Flux: A Major Asteroidal Break up Event at 8.2 Ma.

  18. Characterization of 2 MeV, 4 MeV, 6 MeV and 18 MeV buildup caps for use with a 0.6 cubic centimeter thimble ionization chamber

    SciTech Connect

    Salyer, R.L.; VanDenburg, J.W.; Prinja, A.K.; Kirby, T.; Busch, R.; Hong-Nian Jow

    1996-07-01

    The purpose of this research is to characterize existing 2 MeV, 4 MeV and 6 MeV buildup caps, and to determine if a buildup cap can be made for the 0.6 cm{sup 3} thimble ionization chamber that will accurately measure exposures in a high-energy photon radiation field. Two different radiation transport codes were used to computationally characterize existing 2 MeV, 4 MeV, and 6 MeV buildup caps for a 0.6 cm{sup 3} active volume thimble ionization chamber: ITS, The Integrated TIGER Series of Coupled Electron-Photon Monte Carlo Transport Codes; and CEPXS/ONEDANT, A One-Dimensional Coupled Electron-Photon Discrete Ordinates Code Package. These codes were also used to determine the design characteristics of a buildup cap for use in the 18 MeV photon beam produced by the 14 TW pulsed power HERMES-III electron accelerator. The maximum range of the secondary electron, the depth at which maximum dose occurs, and the point where dose and collision kerma are equal have been determined to establish the validity of electronic equilibrium. The ionization chamber with the appropriate buildup cap was then subjected to a 4 MeV and a 6 MeV bremmstrahlung radiation spectrum to determine the detector response.

  19. Three chamber negative ion source

    DOEpatents

    Leung, Ka-Ngo; Ehlers, Kenneth W.; Hiskes, John R.

    1985-01-01

    A negative ion vessel is divided into an excitation chamber, a negative ionization chamber and an extraction chamber by two magnetic filters. Input means introduces neutral molecules into a first chamber where a first electron discharge means vibrationally excites the molecules which migrate to a second chamber. In the second chamber a second electron discharge means ionizes the molecules, producing negative ions which are extracted into or by a third chamber. A first magnetic filter prevents high energy electrons from entering the negative ionization chamber from the excitation chamber. A second magnetic filter prevents high energy electrons from entering the extraction chamber from the negative ionizing chamber. An extraction grid at the end of the negative ion vessel attracts negative ions into the third chamber and accelerates them. Another grid, located adjacent to the extraction grid, carries a small positive voltage in order to inhibit positive ions from migrating into the extraction chamber and contour the plasma potential. Additional electrons can be suppressed from the output flux using ExB forces provided by magnetic field means and the extractor grid electric potential.

  20. NOTE: Hybrid plan verification for intensity-modulated radiation therapy (IMRT) using the 2D ionization chamber array I'mRT MatriXX—a feasibility study

    NASA Astrophysics Data System (ADS)

    Dobler, Barbara; Streck, Natalia; Klein, Elisabeth; Loeschel, Rainer; Haertl, Petra; Koelbl, Oliver

    2010-01-01

    The 2D ionization chamber array I'mRT MatriXX (IBA, Schwarzenbruck, Germany) has been developed for absolute 2D dosimetry and verification of intensity-modulated radiation therapy (IMRT) for perpendicular beam incidence. The aim of this study is to evaluate the applicability of I'mRT MatriXX for oblique beam incidence and hybrid plan verification of IMRT with original gantry angles. For the assessment of angular dependence, open fields with gantry angles in steps of 10° were calculated on a CT scan of I'mRT MatriXX. For hybrid plan verification, 17 clinical IMRT plans and one rotational plan were used. Calculations were performed with pencil beam (PB), collapsed cone (CC) and Monte Carlo (MC) methods, which had been previously validated. Measurements were conducted on an Elekta SynergyS linear accelerator. To assess the potential and limitations of the system, gamma evaluation was performed with different dose tolerances and distances to agreement. Hybrid plan verification passed the gamma test with 4% dose tolerance and 3 mm distance to agreement in all cases, in 82-88% of the cases for tolerances of 3%/3 mm, and in 59-76% of the cases if 3%/2 mm were used. Separate evaluation of the low dose and high dose regions showed that I'mRT MatriXX can be used for hybrid plan verification of IMRT plans within 3% dose tolerance and 3 mm distance to agreement with a relaxed dose tolerance of 4% in the low dose region outside the multileaf collimator (MLC).

  1. The effect of a compression paddle on energy response, calibration and measurement with mammographic dosimeters using ionization chambers and solid-state detectors.

    PubMed

    Hourdakis, C J; Boziari, A; Koumbouli, E

    2009-02-21

    A compression paddle is always used in mammography x-ray examinations, in order to improve image quality and reduce patient doses. Although clinical dose measurements should be performed with the paddle to interfere with the x-ray beam, calibration of mammography dosimeters is performed free in air without the presence of the paddle. The paddle hardens the x-ray beam, which has an impact on a dosimeter performance, particularly on high-energy-dependent detectors. Due to the paddle, clinical mammography x-ray systems may exhibit beams with HVL values exceeding those of the IEC 61267 RQR-M series qualities at which dosimeters are usually calibrated. In this study, the influence of the paddle in mammography dosimetry is examined, in Mo/Mo anode/filter x-ray qualities. PMMA slabs of 1, 2 and 3 mm thickness and Al foils of 0.05, 0.10 and 0.15 mm thicknesses were used to simulate the paddles, producing beams with HVL values from 0.28 up to 0.43 mmAl. In these qualities, four solid-state (ST) detectors and three ionizations chambers (IC) were calibrated in terms of Kair and N(K) and k(Q) were deduced. The results showed that all IC and two modern-type ST dosimeters have a flat energy response in the above HVL range (less than 3%), so their calibration factor at RQR-M2 quality could be safely used for clinical measurements. Two other ST dosimeters exhibit up to 20% energy response, so differences up to 15% in dose measurement may be observed if the effect of paddle on their performance is ignored. Finally, the need of additional mammographic calibration qualities to the existing IEC 61267 RQR-M series is examined and discussed.

  2. Chemistry of α-pinene and naphthalene oxidation products generated in a Potential Aerosol Mass (PAM) chamber as measured by acetate chemical ionization mass spectrometry

    DOE PAGES

    Chhabra, P. S.; Lambe, A. T.; Canagaratna, M. R.; ...

    2014-07-01

    Recent developments in high resolution, time-of-flight chemical ionization mass spectrometry (HR-ToF-CIMS) have made possible the direct detection of atmospheric organic compounds in real-time with high sensitivity and with little or no fragmentation, including low volatility, highly oxygenated organic vapors that are precursors to secondary organic aerosol formation. Here, for the first time, we examine gas-phase O3 and OH oxidation products of α-pinene and naphthalene formed in the PAM flow reactor with an HR-ToF-CIMS using acetate reagent ion chemistry. Integrated OH exposures ranged from 1.2 × 1011 to 9.7 × 1011 molec cm−3 s, corresponding to approximately 1.0 to 7.5 daysmore » of equivalent atmospheric oxidation. Measured gas-phase organic acids are similar to those previously observed in environmental chamber studies. For both precursors, we find that acetate-CIMS spectra capture both functionalization (oxygen addition) and fragmentation (carbon loss) as a function of OH exposure. The level of fragmentation is observed to increase with increased oxidation. We present a method that estimates vapor pressures of organic molecules using the measured O/C ratio, H/C ratio, and carbon number for each compound detected by the CIMS. The predicted condensed-phase SOA average acid yields and O/C and H/C ratios agree within uncertainties with previous AMS measurements and ambient CIMS results. While acetate reagent ion chemistry is used to selectively measure organic acids, in principle this method can be applied to additional reagent ion chemistries depending on the application.« less

  3. Development of D+3He Fusion Electric Thrusters and Power Supplies for Space

    NASA Astrophysics Data System (ADS)

    Morse, Thomas M.

    1994-07-01

    Development of D+3He Fusion Electric Thrusters (FET) and Power Supplies (FPS) should occur at a lunar base because of the following: availability of helium-3, a vacuum better than on Earth, low K in shade reachable by radiant cooling, supply of ``high temp'' superconducting ceramic-metals, and a low G environment. The early FET will be much smaller than an Apollo engine, with specific impulse of 10,000-100,000-s. Solar power and low G will aid early development. To counter the effect of low G on humans, centrifuges will be employed for sleeping and resting. Work will be done by telerobotic view control. The FPS will be of comparable size, and will generate power mainly by having replaceable rectennas, resonant to the fusion synchrotron radiation. FPSs are used for house keeping power and initiating superconduction. Spaceships will carry up to ten FETs and two FPSs. In addition to fusion fuel, the FET will inject H or Li low mass propellant into the fusion chamber. Developing an FET would be difficult on Earth. FET spaceships will park between missions in L1, and an FET Bus will fetch humans/supplies from Moon and Earth. Someday FETs, with rocket assist, will lift spaceships from Earth, and make space travel to planets far cheaper, faster, and safer, than at present. Too long a delay due to the space station, or the huge cost of getting into space by current means, will damage the morale of the space program.

  4. SU-E-T-35: An Investigation of the Accuracy of Cervical IMRT Dose Distribution Using 2D/3D Ionization Chamber Arrays System and Monte Carlo Simulation

    SciTech Connect

    Zhang, Y; Yang, J; Liu, H; Liu, D

    2014-06-01

    Purpose: The purpose of this work is to compare the verification results of three solutions (2D/3D ionization chamber arrays measurement and Monte Carlo simulation), the results will help make a clinical decision as how to do our cervical IMRT verification. Methods: Seven cervical cases were planned with Pinnacle 8.0m to meet the clinical acceptance criteria. The plans were recalculated in the Matrixx and Delta4 phantom with the accurate plans parameters. The plans were also recalculated by Monte Carlo using leaf sequences and MUs for individual plans of every patient, Matrixx and Delta4 phantom. All plans of Matrixx and Delta4 phantom were delivered and measured. The dose distribution of iso slice, dose profiles, gamma maps of every beam were used to evaluate the agreement. Dose-volume histograms were also compared. Results: The dose distribution of iso slice and dose profiles from Pinnacle calculation were in agreement with the Monte Carlo simulation, Matrixx and Delta4 measurement. A 95.2%/91.3% gamma pass ratio was obtained between the Matrixx/Delta4 measurement and Pinnacle distributions within 3mm/3% gamma criteria. A 96.4%/95.6% gamma pass ratio was obtained between the Matrixx/Delta4 measurement and Monte Carlo simulation within 2mm/2% gamma criteria, almost 100% gamma pass ratio within 3mm/3% gamma criteria. The DVH plot have slightly differences between Pinnacle and Delta4 measurement as well as Pinnacle and Monte Carlo simulation, but have excellent agreement between Delta4 measurement and Monte Carlo simulation. Conclusion: It was shown that Matrixx/Delta4 and Monte Carlo simulation can be used very efficiently to verify cervical IMRT delivery. In terms of Gamma value the pass ratio of Matrixx was little higher, however, Delta4 showed more problem fields. The primary advantage of Delta4 is the fact it can measure true 3D dosimetry while Monte Carlo can simulate in patients CT images but not in phantom.

  5. Ionization detection system for aerosols

    DOEpatents

    Jacobs, Martin E.

    1977-01-01

    This invention relates to an improved smoke-detection system of the ionization-chamber type. In the preferred embodiment, the system utilizes a conventional detector head comprising a measuring ionization chamber, a reference ionization chamber, and a normally non-conductive gas triode for discharging when a threshold concentration of airborne particulates is present in the measuring chamber. The improved system utilizes a measuring ionization chamber which is modified to minimize false alarms and reductions in sensitivity resulting from changes in ambient temperature. In the preferred form of the modification, an annular radiation shield is mounted about the usual radiation source provided to effect ionization in the measuring chamber. The shield is supported by a bimetallic strip which flexes in response to changes in ambient temperature, moving the shield relative to the source so as to vary the radiative area of the source in a manner offsetting temperature-induced variations in the sensitivity of the chamber.

  6. A possible in situ 3H and 3He source in Earth's interior: an alternative explanation of origin of 3He in deep Earth.

    PubMed

    Jiang, Songsheng; Liu, Jing; He, Ming

    2010-07-01

    Origin of (3)He in the Earth is a mystery. Lacking a production mechanism, scientists assume (3)He was trapped in the Earth, when the Earth was formed. In contrast to this assumption, we have found (3)He and (3)H concentrations in excess of the atmospheric values in the deep waters of the volcanic Lakes Pavin (France), Laacher (Germany) and Nemrut (Turkey). This paper reports the result of finding (3)H in these three volcanic lakes that appear to originate from the mantle. Because (3)H has a half-life of 12.3 years, this (3)H and the resulting (3)He must have formed recently in the mantle and not be part of a primordial reservoir. The nuclear reactions that generate tritium might be a source of "missing" energy in the interior of the Earth.

  7. SU-E-T-552: Monte Carlo Calculation of Correction Factors for a Free-Air Ionization Chamber in Support of a National Air-Kerma Standard for Electronic Brachytherapy

    SciTech Connect

    Mille, M; Bergstrom, P

    2015-06-15

    Purpose: To use Monte Carlo radiation transport methods to calculate correction factors for a free-air ionization chamber in support of a national air-kerma standard for low-energy, miniature x-ray sources used for electronic brachytherapy (eBx). Methods: The NIST is establishing a calibration service for well-type ionization chambers used to characterize the strength of eBx sources prior to clinical use. The calibration approach involves establishing the well-chamber’s response to an eBx source whose air-kerma rate at a 50 cm distance is determined through a primary measurement performed using the Lamperti free-air ionization chamber. However, the free-air chamber measurements of charge or current can only be related to the reference air-kerma standard after applying several corrections, some of which are best determined via Monte Carlo simulation. To this end, a detailed geometric model of the Lamperti chamber was developed in the EGSnrc code based on the engineering drawings of the instrument. The egs-fac user code in EGSnrc was then used to calculate energy-dependent correction factors which account for missing or undesired ionization arising from effects such as: (1) attenuation and scatter of the x-rays in air; (2) primary electrons escaping the charge collection region; (3) lack of charged particle equilibrium; (4) atomic fluorescence and bremsstrahlung radiation. Results: Energy-dependent correction factors were calculated assuming a monoenergetic point source with the photon energy ranging from 2 keV to 60 keV in 2 keV increments. Sufficient photon histories were simulated so that the Monte Carlo statistical uncertainty of the correction factors was less than 0.01%. The correction factors for a specific eBx source will be determined by integrating these tabulated results over its measured x-ray spectrum. Conclusion: The correction factors calculated in this work are important for establishing a national standard for eBx which will help ensure that dose

  8. Near threshold two meson production with the pd→3Heπ+π- and pd→3HeK+K- reactions

    NASA Astrophysics Data System (ADS)

    Bellemann, F.; Berg, A.; Bisplinghoff, J.; Bohlscheid, G.; Ernst, J.; Henrich, C.; Hinterberger, F.; Ibald, R.; Jahn, R.; Jarczyk, L.; Joosten, R.; Kozela, A.; Machner, H.; Magiera, A.; Maschuw, R.; Mayer-Kuckuk, T.; Mertler, G.; Munkel, J.; von Neumann-Cosel, P.; Rosendaal, D.; von Rossen, P.; Schnitker, H.; Scho, K.; Smyrski, J.; Strzalkowski, A.; Tölle, R.; Wilkin, C.

    2000-06-01

    Near threshold two meson production via the reactions pd→3Heπ+π- and pd→3HeK+K- was measured kinematically complete with the MOMO experiment at COSY. The obtained two pion invariant mass spectra and angular distributions depict a remarkable deviation from phase space. The two kaon data are consistent with phase space topped by a clear signal of the φ meson.

  9. Thermodynamic properties of liquid 3He- 4He mixtures at zero pressure for temperatures below 250 mK and 3He concentrations below 8%

    NASA Astrophysics Data System (ADS)

    Kuerten, J. G. M.; Castelijns, C. A. M.; de Waele, A. T. A. M.; Gijsman, H. M.

    We calculated the thermodynamic quantities of dilute liquid 3He- 4He mixtures, starting from experimental values of the specific heat and the osmotic pressure. The calculations are confined to temperatures below 250 mK and 3He concentrations below 8% at zero pressure. Some results are especially useful for dilution refrigeration. Contrary to the calculations previously performed by Radebaugh, our results are in good agreement with the experimental date on both the osmotic pressure and the osmotic enthalpy.

  10. The influence of restricted geometry of diamagnetic nanoporous media on 3He relaxation

    NASA Astrophysics Data System (ADS)

    Alakshin, E. M.; Gazizulin, R. R.; Zakharov, M. Yu.; Klochkov, A. V.; Morozov, E. V.; Salikhov, T. M.; Safin, T. R.; Safiullin, K. R.; Tagirov, M. S.; Shabanova, O. B.

    2015-01-01

    This is an experimental study of the spin kinetics of 3He in contact with diamagnetic samples of inverse opals SiO2, and LaF3 nanopowder. It is demonstrated that the nuclear magnetic relaxation of the absorbed 3He occurs due to the modulation of dipole-dipole interaction by the quantum motion in the two-dimensional film. It is found that the relaxation of liquid 3He occurs through a spin diffusion to the absorption layer, and that the restricted geometry of diamagnetic nanoporous media has an influence on the 3He relaxation.

  11. Transport in very dilute solutions of 3He in superfluid 4He

    NASA Astrophysics Data System (ADS)

    Baym, Gordon; Beck, D. H.; Pethick, C. J.

    2013-07-01

    Motivated by a proposed experimental search for the electric dipole moment of the neutron (nEDM) utilizing neutron-3He capture in a dilute solution of 3He in superfluid 4He, we derive the transport properties of dilute solutions in the regime where the 3He are classically distributed and rapid 3He-3He scatterings keep the 3He in equilibrium. Our microscopic framework takes into account phonon-phonon, phonon-3He, and 3He-3He scatterings. We then apply these calculations to measurements by Rosenbaum [J. Low Temp. Phys.JLTPAC0022-229110.1007/BF00655864 16, 131 (1974)] and by Lamoreaux [Europhys. Lett.EULEEJ0295-507510.1209/epl/i2002-00408-4 58, 718 (2002)] of dilute solutions in the presence of a heat flow. We find satisfactory agreement of theory with the data, serving to confirm our understanding of the microscopics of the helium in the future nEDM experiment.

  12. (3)He-MRI in follow-up of lung transplant recipients.

    PubMed

    Gast, Klaus Kurt; Zaporozhan, Julia; Ley, Sebastian; Biedermann, Alexander; Knitz, Frank; Eberle, Balthasar; Schmiedeskamp, Joerg; Heussel, Claus-Peter; Mayer, Eckhard; Schreiber, Wolfgang Günter; Thelen, Manfred; Kauczor, Hans-Ulrich

    2004-01-01

    The aim of this study was to evaluate the possible contribution of (3)He-MRI to detect obliterative bronchiolitis (OB) in the follow-up of lung transplant recipients. Nine single- and double-lung transplanted patients were studied by an initial and a follow-up (3)He-MRI study. Images were evaluated subjectively by estimation of ventilation defect area and quantitatively by individually adapted threshold segmentation and subsequent calculation of ventilated lung volume. Bronchiolitis obliterans syndrome (BOS) was diagnosed using pulmonary function tests. At (3)He-MRI, OB was suspected if ventilated lung volume had decreased by 10% or more at the follow-up MRI study compared with the initial study. General accordance between pulmonary function testing and (3)He-MRI was good, although subjective evaluation of (3)He-MRI underestimated improvement in ventilation as obtained by pulmonary function tests. The (3)He-MRI indicated OB in 6 cases. According to pulmonary function tests, BOS was diagnosed in 5 cases. All diagnoses of BOS were also detected by (3)He-MRI. In 2 of these 5 cases, (3)He-MRI indicated OB earlier than pulmonary function tests. The results support the hypothesis that (3)He-MRI may be sensitive for early detection of OB and emphasize the need for larger prospective follow-up studies.

  13. Cluster folding model analysis of 3He elastic and inelastic scattering from 12C

    NASA Astrophysics Data System (ADS)

    Khallaf, S. A. E.; Nossair, A. M. A.; Ebrahim, A. A.; Ebraheem, Awad A.

    2003-02-01

    Angular distributions of differential cross sections for the 12C( 3He, 3He) 12C, 12C( 3He, 3He) 12C ∗ reactions at E=72 MeV have been analyzed with a double folding cluster model DFC based on five sets of the effective N-N interaction of Gaussian form with different parameters. The transition to the (2 +; 4.44 MeV) state in 12C is studied and the deformation length δ2 is extracted. It is found that the extracted deformation length is sensitive to the nuclear model used and it is similar to the corresponding value found in the literature.

  14. SU-E-T-225: Correction Matrix for PinPoint Ionization Chamber for Dosimetric Measurements in the Newly Released Incise™ Multileaf Collimator Shaped Small Field for CyberKnife M6™ Machine

    SciTech Connect

    Zhang, Y; Li, T; Heron, D; Huq, M

    2015-06-15

    Purpose: For small field dosimetry, such as measurements of output factors for cones or MLC-shaped irregular small fields, ion chambers often Result in an underestimation of the dose, due to both the volume averaging effect and the lack of lateral charged particle equilibrium. This work presents a mathematical model for correction matrix for a PTW PinPoint ionization chamber for dosimetric measurements made in the newly released Incise™ Multileaf collimator fields of the CyberKnife M6™ machine. Methods: A correction matrix for a PTW 0.015cc PinPoint ionization chamber was developed by modeling its 3D dose response in twelve cone-shaped circular fields created using the 5mm, 7.5mm, 10mm, 12.5mm, 15mm, 20mm, 25mm, 30mm, 35mm, 40mm, 50mm, 60mm cones in a CyberKnife M6™ machine. For each field size, hundreds of readings were recorded for every 2mm chamber shift in the horizontal plane. The contribution of each dose pixel to a measurement point depended on the radial distance and the angle to the chamber axis. These readings were then compared with the theoretical dose as obtained with Monte Carlo calculation. A penalized least-square optimization algorithm was developed to generate the correction matrix. After the parameter fitting, the mathematical model was validated for MLC-shaped irregular fields. Results: The optimization algorithm used for parameter fitting was stable and the resulted response factors were smooth in spatial domain. After correction with the mathematical model, the chamber reading matched with the calculation for all the tested fields to within 2%. Conclusion: A novel mathematical model has been developed for PinPoint chamber for dosimetric measurements in small MLC-shaped irregular fields. The correction matrix is dependent on detector, treatment unit and the geometry of setup. The model can be applied to non-standard composite fields and provides an access to IMRT point dose validation.

  15. Flow chamber

    SciTech Connect

    Morozov, Victor

    2011-01-18

    A flow chamber having a vacuum chamber and a specimen chamber. The specimen chamber may have an opening through which a fluid may be introduced and an opening through which the fluid may exit. The vacuum chamber may have an opening through which contents of the vacuum chamber may be evacuated. A portion of the flow chamber may be flexible, and a vacuum may be used to hold the components of the flow chamber together.

  16. Practical method for determination of air kerma by use of an ionization chamber toward construction of a secondary X-ray field to be used in clinical examination rooms.

    PubMed

    Maehata, Itsumi; Hayashi, Hiroaki; Kimoto, Natsumi; Takegami, Kazuki; Okino, Hiroki; Kanazawa, Yuki; Tominaga, Masahide

    2016-07-01

    We propose a new practical method for the construction of an accurate secondary X-ray field using medical diagnostic X-ray equipment. For accurate measurement of the air kerma of an X-ray field, it is important to reduce and evaluate the contamination rate of scattered X-rays. To determine the rate quantitatively, we performed the following studies. First, we developed a shield box in which an ionization chamber could be set at an inner of the box to prevent detection of the X-rays scattered from the air. In addition, we made collimator plates which were placed near the X-ray source for estimation of the contamination rate by scattered X-rays from the movable diaphragm which is a component of the X-ray equipment. Then, we measured the exposure dose while changing the collimator plates, which had diameters of 25-90 mm(ϕ). The ideal value of the exposure dose was derived mathematically by extrapolation to 0 mm(ϕ). Tube voltages ranged from 40 to 130 kV. Under these irradiation conditions, we analyzed the contamination rate by the scattered X-rays. We found that the contamination rates were less than 1.7 and 2.3 %, caused by air and the movable diaphragm, respectively. The extrapolated value of the exposure dose has been determined to have an uncertainty of 0.7 %. The ionization chamber used in this study was calibrated with an accuracy of 5 %. Using this kind of ionization chamber, we can construct a secondary X-ray field with an uncertainty of 5 %.

  17. Calculation of reactivities using ionization chamber currents with different sets of kinetic parameters for reduced scram system efficiency in the VVER-1000 of the third unit of the Kalinin nuclear power plant at the stage of physical start-up

    SciTech Connect

    Zizin, M. N.; Zizina, S. N.; Kryakvin, L. V.; Pitilimov, V. A.; Tereshonok, V. A.

    2011-12-15

    The effectiveness of the VVER-1000 reactor scram system is analyzed using ionization chamber currents with different sets of kinetic parameters with allowance for the isotopic composition in the calculation of these parameters. The most 'correct, aesthetically acceptable' results are obtained using the eight-group constants of the ROSFOND (BNAB-RF) library. The difference between the maximum and minimum values of the scram system effectiveness calculated with different sets of kinetic parameters slightly exceeds 2{beta}. The problems of introducing corrections due to spatial effects are not considered in this study.

  18. Measurement of fast minority /sub 3/He/sup + +/ energy distribution during ICRF heating

    DOEpatents

    Post, D.E. Jr.; Grisham, L.R.; Medley, S.S.

    A method and means for measuring the fast /sub 3/He/sup + +/ distribution during /sub 3/He/sup + +/ minority Ion Cyclotron Resonance Frequency (ICRF) heating is disclosed. The present invention involves the use of 10 to 100 keV beams of neutral helium atoms to neutralize the fast /sub 3/He/sup + +/ ions in a heated plasma by double charge exchange (/sub 3/He/sup + +/ + /sub 4/He/sup 0/ ..-->.. /sub 3/He/sup 0/ + /sub 4/He/sup + +/). The neutralized fast /sub 3/He/sup 0/ atoms then escape from the hot plasma confined by a magnetic field and are detected by conventional neutral particle analyzing means. This technique permits the effectiveness of the coupling of the ion cyclotron waves to the /sub 3/He/sup + +/ minority ions to be accurately measured. The present invention is particularly adapted for use in evaluating the effectiveness of the intermediate coupling between the RF heating and the /sub 3/He/sup + +/ in an energetic toroidal plasma.

  19. Type 3 solar radio bursts and 3HE-rich events

    NASA Technical Reports Server (NTRS)

    Reames, D. V.; Stone, R. G.

    1985-01-01

    The kilometric radio data for 3He-rich events during the 1979 to 82 time period were investigated. Type 3 bursts are present for each event as expected from the prevous electron 3He-event association. A list of identified solar events is presented.

  20. Fusion product studies via fast ion D-D and D-3He fusion on JET

    NASA Astrophysics Data System (ADS)

    Sharapov, S. E.; Hellsten, T.; Kiptily, V. G.; Craciunescu, T.; Eriksson, J.; Fitzgerald, M.; Girardo, J.-B.; Goloborod'ko, V.; Hellesen, C.; Hjalmarsson, A.; Johnson, T.; Kazakov, Y.; Koskela, T.; Mantsinen, M.; Monakhov, I.; Nabais, F.; Nocente, M.; Perez von Thun, C.; Rimini, F.; Santala, M.; Schneider, M.; Tardocchi, M.; Tsalas, M.; Yavorskij, V.; Zoita, V.; Contributors, JET

    2016-11-01

    Dedicated fast ion D-D and D-3He fusion experiments were performed on JET with carbon wall (2008) and ITER-like wall (2014) for testing the upgraded neutron and energetic ion diagnostics of fusion products. Energy spectrum of D-D neutrons was the focus of the studies in pure deuterium plasmas. A significant broadening of the energy spectrum of neutrons born in D-D fast fusion was observed, and dependence of the maximum D and D-D neutron energies on plasma density was established. Diagnostics of charged products of aneutronic D-3He fusion reactions, 3.7 MeV alpha-particles similar to those in D-T fusion, and 14.6 MeV protons, were the focus of the studies in D-3He plasmas. Measurements of 16.4 MeV gamma-rays born in the weak secondary branch of D(3He, γ)5Li reaction were used for assessing D-3He fusion power. For achieving high yield of D-D and D-3He reactions at relatively low levels of input heating power, an acceleration of D beam up to the MeV energy range was used employing 3rd harmonic (f=3{{f}CD} ) ICRH technique. These results were compared to the techniques of D beam injection into D-3He mixture, and 3He-minority ICRH in D plasmas.

  1. 4 He adsorption on a 3He-plated graphite surface

    NASA Astrophysics Data System (ADS)

    Kwon, Yongkyung; Ahn, Jeonghwan

    Path-integral Monte Carlo (PIMC) calculations have been performed for 4He atoms on top of the 3He first layer on graphite. For this we ignore Fermi statistics of solidified 3He adatoms while Bose statistics of 4He atoms are fully incorporated. We first find that the first 3He layer exhibits a 7/12 commensurate solid structure at the areal density of 0.111 Å-2, which turns out to be identical to the experimental value for its completion density. Additional adsorption of 4He atoms above the complete first 3He layer is found to sustain the underlying 3He commensurate structure and the second 4He layer is observed to display the 4/7 commensurate structure with respect to the first-layer commensurate 3He solid at the areal density of 0.0636 Å-2. Furthermore, it is found that the 4/7 commensurate structure of the second-layer 4He atoms can be formed above a mixture of the first-layer 3He and 4He atoms on graphite. These PIMC results suggest that the 4/7 commensurate structure of the second-layer 4He atoms on graphite, whose existence on top of the first 4He layer has long been in dispute, may be realized on a 3He-plated graphite surface. This could lead to a new approach to observe two-dimensional supersolidity in 4He on graphite.

  2. Nuclear georeactor origin of oceanic basalt 3He/4He, evidence, and implications.

    PubMed

    Herndon, J Marvin

    2003-03-18

    Nuclear georeactor numerical simulation results yield substantial (3)He and (4)He production and (3)He(4)He ratios relative to air (R(A)) that encompass the entire 2-SD (2sigma) confidence level range of tabulated measured (3)He(4)He ratios of basalts from along the global spreading ridge system. Georeactor-produced (3)He(4)He ratios are related to the extent of actinide fuel consumption at time of production and are high near the end of the georeactor lifetime. Georeactor numerical simulation results and the observed high (3)He(4)He ratios measured in Icelandic and Hawaiian oceanic basalts indicate that the demise of the georeactor is approaching. Within the present level of uncertainty, one cannot say precisely when georeactor demise will occur, whether in the next century, in a million years, or in a billion years from now.

  3. Nuclear georeactor origin of oceanic basalt 3He/4He, evidence, and implications

    PubMed Central

    Herndon, J. Marvin

    2003-01-01

    Nuclear georeactor numerical simulation results yield substantial 3He and 4He production and 3He/4He ratios relative to air (RA) that encompass the entire 2-SD (2σ) confidence level range of tabulated measured 3He/4He ratios of basalts from along the global spreading ridge system. Georeactor-produced 3He/4He ratios are related to the extent of actinide fuel consumption at time of production and are high near the end of the georeactor lifetime. Georeactor numerical simulation results and the observed high 3He/4He ratios measured in Icelandic and Hawaiian oceanic basalts indicate that the demise of the georeactor is approaching. Within the present level of uncertainty, one cannot say precisely when georeactor demise will occur, whether in the next century, in a million years, or in a billion years from now. PMID:12615991

  4. Application of Sol-Gel Technology to High Pressure Polarized 3HE Nuclear Targets

    NASA Astrophysics Data System (ADS)

    Tobias, W. A.; Cates, G. D.; Chaput, J.; Deur, A.; Rohrbaugh, S.; Singh, J.

    2003-01-01

    High-purity sol-gel solutions have been developed to coat the interior surface of glass vessels used for polarizing 3He by spin-exchange optical pumping. Such cells have been shown to exhibit 3He longitudinal lifetimes T1 in excess of 350 hours1. The sol-gel technique was designed to minimize spin-relaxation due to wall collisions so that only dipole-dipole interactions between colliding 3He atoms dominate in the relaxation process. Until now, sol-gel technology had not been applied to high pressure 3He gas targets used in nuclear scattering experiments. A description of the sol-gel technique and recent developments on its integration into the production of 3He targets will be presented.

  5. The injection of ten electron/3He-rich SEP events

    NASA Astrophysics Data System (ADS)

    Wang, Linghua; Mason, Glenn; Krucker, Samuel; Li, Gang

    2016-07-01

    We have derived the particle injections at the Sun for ten good electron/ ^{3}He-rich solar energetic particle (SEP) events, using a 1.2 AU particle path length (suggested by analysis of the velocity dispersion). The inferred solar injections of high-energy (˜10 to 300 keV) electrons and of ˜MeV/nucleon ions (carbon and heavier) start with a delay of 17±3 minutes and 75±±14 minutes, respectively, after the injection of low-energy (˜0.4 to 9 keV) electrons. The injection duration (averaged over energy) ranges from ˜200 to 550 minutes for ions, from ˜90 to 160 minutes for low-energy electrons, and from ˜10 to 30 minutes for high-energy electrons. Most of the selected events have no reported H_{α} flares or GOES SXR bursts, but all have type III radio bursts that typically start after the onset of a low-energy electron injection. All nine events with SOHO/LASCO coverage have a relatively fast (>570km/s), mostly narrow (≲30°), west-limb coronal mass ejection (CME) that launches near the start of the low-energy electron injection, and reaches an average altitude of ˜1.0 and 4.7 R _{S} , respectively, at the start of the high-energy electron injection and of the ion injection. The electron energy spectra show a continuous power law extending across the transition from low to high energies, suggesting that the low-energy electron injection may provide seed electrons for the delayed high-energy electron acceleration. The delayed ion injections and high ionization states may suggest an ion acceleration along the lower altitude flanks, rather than at the nose of the CMEs.

  6. T(T,2n)4He and 3He(3He,2p)4He: The Reaction Mechanism from Solar Energies to 10 MeV

    NASA Astrophysics Data System (ADS)

    Bacher, A. D.; Brune, C. R.; Sayre, D. B.; Hale, G. M.; Frenje, J. A.; Gatu Johnson, M.

    2016-03-01

    We have studied the energy dependence of the reaction mechanism of the T(t,2n)4He reaction at stellar energies and of its charge symmetric analog reaction 3He(3He,2p)4He at energies up 10 MeV. We find that the reaction mechanism changes dramatically over this energy range in part due to the interference of the two identical fermions in the three-body final state. This contribution is dedicated to the memory of Tom Tombrello, my Ph.D. advisor at Cal Tech, who died in 2014.

  7. Interpretation of the Processes 3He(e,e'p)2H and 3He(e,e'p)(pn) at High Missing Momenta

    NASA Astrophysics Data System (ADS)

    Ciofi Degli Atti, C.; Kaptari, L. P.

    2005-07-01

    Using realistic three-body wave functions corresponding to the AV18 interaction, it is shown that the effects of the final state interaction in the exclusive processes 3He(e,e'p)2H and 3He(e,e'p)(pn), can be successfully treated in terms of a generalized eikonal approximation based upon the direct calculation of the Feynman diagrams describing the rescattering of the struck nucleon. The relevant role played by the double rescattering contribution at high values of the missing momentum is illustrated.

  8. Interpretation of the processes 3He(e,e'p)2H and 3He(e,e'p)(pn) at high missing momenta.

    PubMed

    Ciofi degli Atti, C; Kaptari, L P

    2005-07-29

    Using realistic three-body wave functions corresponding to the AV18 interaction, it is shown that the effects of the final state interaction in the exclusive processes 3He(e,e'p)2H and 3He(e,e'p)(pn), can be successfully treated in terms of a generalized eikonal approximation based upon the direct calculation of the Feynman diagrams describing the rescattering of the struck nucleon. The relevant role played by the double rescattering contribution at high values of the missing momentum is illustrated.

  9. Gas cells for 3He hyperpolarized via spin-exchange optical pumping

    NASA Astrophysics Data System (ADS)

    Kim, W.; Stepanyan, S. S.; Kim, A.; Tan, J. A.; Woo, S.

    2016-01-01

    We present a device for the production of hyperpolarized 3He, which is widely used in spinrelated nuclear physics research. Spin-exchange optical pumping (SEOP) is employed to polarize 3He enclosed in a circular borosilicate glass cell suitable not only for the production of polarized gas but also for its storage. The portable glass cell can, thus, be transported to any other research facility. The glass cell can be refilled several times. Special attention is given to the preparation and the filling of the cell to minimize the impurities on its walls and in the gas. We employ glass tubes with shorter lengths and larger diameters in the gas-filling system to achieve the improvement in the air flow necessary to obtain purer polarized 3He samples. The cell is prepared, and after it has been filled with rubidium (Rb) and 3He-N2 mixture, it is sealed under high vacuum conditions. The cell containing the mixture is exposed to circularly-polarized laser light with a wavelength of 795 nm at temperatures of 180 - 220 °C for SEOP. The polarization of 3He is measured via nuclear magnetic resonance (NMR). We obtained 40% polarized 3He in less than 15 hours and 50% in about 25 hours. The longitudinal relaxation time T 1 of the polarized 3He we measured was about 58 hours.

  10. Cosmogenic 3He in terrestrial rocks: The summit lavas of Maui

    PubMed Central

    Craig, H.; Poreda, R. J.

    1986-01-01

    We have identified terrestrial cosmic rayproduced 3He in three lava flows on the crest of Haleakala Volcano on Maui, 3 km above sea level, and ≈0.5 million years old. Although these lavas, like all oceanic basalts, contain primordial 3He from the mantle, the “cosmogenic” component (3HeC) can be identified unambiguously because it is extractable only by high-temperature vacuum fusion. In contrast, a large fraction of the mantle helium resides in fluid inclusions and can be extracted by vacuum crushing, leaving a residual component with 3He/4He ratios as high as 75× those in the atmosphere, which can be liberated by melting the crushed grains. Cosmogenic 3He is present in both olivines and clinopyroxenes at 0.8-1.2 × 10-12 ml(STP)/g and constitutes 75% ± 5% of the total 3He present. The observed 3HeC levels require a cosmic ray exposure age of only some 64,000 years, much less than the actual age of the lavas, if there is no erosion. Using a model that includes effects of uplift or submergence as well as erosion, we calculate an apparent “erosion rate” of the order of 8.5 m/106 years for the western rim of the summit crater, as an example of the application of measurements of cosmogenic rare gases to terrestrial geological problems. PMID:16593671

  11. Third sound and stability of 3He-4He mixture films

    SciTech Connect

    Anderson, R. H.; Krotscheck, E.; Miller, M. D.

    2006-09-07

    We study third sound and the interaction between 3He adatoms in two thin 3He-4He mixture films from a first-principles, microscopic theory. Utilizing the variational, hypernetted-chain Euler-Lagrange (HNC-EL) theory as applied to inhomogeneous boson systems, we calculate chemical potentials for both the 4He superfluid film and the physisorbed 3He. Numerical density derivatives of the chemical potentials lead to the sought-after third sound speeds that clearly reflect a layered structure of at least seven oscillations. In this paper, we report third sound on model substrates: Nuclepore, and sodium. We find that the effect of the 3He depends sensitively on the particular 4He film coverage. Our most important result is that, with the addition of 3He, the third sound speed can either increase or decrease. In fact, in some regimes, the added 3He destabilizes the film and can drive ''layering transitions'', leading to fairly complicated geometric structures of the film in which the outermost layer is predicted to consist of phase-separated regions of 3He and 4He.

  12. Recent advances in polarized 3 He based neutron spin filter development

    NASA Astrophysics Data System (ADS)

    Chen, Wangchun; Gentile, Thomas; Erwin, Ross; Watson, Shannon; Krycka, Kathryn; Ye, Qiang; NCNR NIST Team; University of Maryland Team

    2015-04-01

    Polarized 3 He neutron spin filters (NSFs) are based on the strong spin-dependence of the neutron absorption cross section by 3 He. NSFs can polarize large area, widely divergent, and broadband neutron beams effectively and allow for combining a neutron polarizer and a spin flipper into a single polarizing device. The last capability utilizes 3 He spin inversion based on the adiabatic fast passage (AFP) nuclear magnetic resonance technique. Polarized 3 He NSFs are significantly expanding the polarized neutron measurement capabilities at the NIST Center for Neutron Research (NCNR). Here we present an overview of 3 He NSF applications to small-angle neutron scattering, thermal triple axis spectrometry, and wide-angle polarization analysis. We discuss a recent upgrade of our spin-exchange optical pumping (SEOP) systems that utilize chirped volume holographic gratings for spectral narrowing. The new capability allows us to polarize rubidium/potassium hybrid SEOP cells over a liter in volume within a day, with 3 He polarizations up to 88%, Finally we discuss how we can achieve nearly lossless 3 He polarization inversion with AFP.

  13. Enhanced IR hollow cathode laser in a 3He Ne gas mixture

    NASA Astrophysics Data System (ADS)

    Stefanova, M. S.; Pramatarov, P. M.; Karelin, A. V.

    2005-09-01

    An experimental and theoretical study on 3He-Ne and 4He-Ne helical hollow cathode lasers is presented. Enhanced laser operation on the near IR NeI lines is observed when the natural isotope 4He is substituted by the lighter isotope 3He. A four-fold increase in the laser output power and a three-fold increase in the laser gain for the strongest NeI 1.1523 µm line is measured in the 3He-Ne gas mixture compared to the 4He-Ne gas mixture. On the basis of the theoretical analysis done by means of a non-stationary kinetic model for the negative glow plasma of 3He-Ne and 4He-Ne hollow cathode lasers, a study on the changes in the particle kinetics is carried out and an explanation of the experimental results is proposed. In the 3He-Ne mixture the electron temperature is lower than in the 4He-Ne mixture, while the gas temperature is higher. As a result the helium triplet metastable density and the rate constant for excitation transfer to neon atoms are higher in the 3He-Ne mixture. The lower laser level de-excitation due to intra-multiplet mixing of 2p1-10levels by 3He atoms is more efficient.

  14. Anomalous yield reduction in direct-drive DT implosions due to 3He addition

    SciTech Connect

    Herrmann, Hans W; Langenbrunner, James R; Mack, Joseph M; Cooley, James H; Wilson, Douglas C; Evans, Scott C; Sedillo, Tom J; Kyrala, George A; Caldwell, Stephen E; Young, Carlton A; Nobile, Arthur; Wermer, Joseph R; Paglieri, Stephen N; Mcevoy, Aaron M; Kim, Yong Ho; Batha, Steven H; Horsfield, Colin J; Drew, Dave; Garbett, Warren; Rubery, Michael; Glebov, Vladimir Yu; Roberts, Samuel; Frenje, Johan A

    2008-01-01

    Glass capsules were imploded in direct drive on the OMEGA laser [T. R. Boehly et aI., Opt. Commun. 133, 495, 1997] to look for anomalous degradation in deuterium/tritium (DT) yield (i.e., beyond what is predicted) and changes in reaction history with {sup 3}He addition. Such anomalies have previously been reported for D/{sup 3}He plasmas, but had not yet been investigated for DT/{sup 3}He. Anomalies such as these provide fertile ground for furthering our physics understanding of ICF implosions and capsule performance. A relatively short laser pulse (600 ps) was used to provide some degree of temporal separation between shock and compression yield components for analysis. Anomalous degradation in the compression component of yield was observed, consistent with the 'factor of two' degradation previously reported by MIT at a 50% {sup 3}He atom fraction in D{sub 2} using plastic capsules [Rygg et aI., Phys. Plasmas 13, 052702 (2006)]. However, clean calculations (i.e., no fuel-shell mixing) predict the shock component of yield quite well, contrary to the result reported by MIT, but consistent with LANL results in D{sub 2}/{sup 3}He [Wilson, et aI., lml Phys: Conf Series 112, 022015 (2008)]. X-ray imaging suggests less-than-predicted compression ofcapsules containing {sup 3}He. Leading candidate explanations are poorly understood Equation-of-State (EOS) for gas mixtures, and unanticipated particle pressure variation with increasing {sup 3}He addition.

  15. The cosmological density of baryons from observations of 3He+ in the Milky Way.

    PubMed

    Bania, T M; Rood, Robert T; Balser, Dana S

    2002-01-03

    Primordial nucleosynthesis after the Big Bang can be constrained by the abundances of the light elements and isotopes 2H, 3He, 4He and 7Li (ref. 1). The standard theory of stellar evolution predicts that 3He is also produced by solar-type stars, so its abundance is of interest not only for cosmology, but also for understanding stellar evolution and the chemical evolution of the Galaxy. The 3He abundance in star-forming (H II) regions agrees with the present value for the local interstellar medium, but seems to be incompatible with the stellar production rates inferred from observations of planetary nebulae, which provide a direct test of stellar evolution theory. Here we develop our earlier observations, which, when combined with recent theoretical developments in our understanding of light-element synthesis and destruction in stars, allow us to determine an upper limit for the primordial abundance of 3He relative to hydrogen: 3He/H = (1.1 +/- 0.2) x 10(-5). The primordial density of all baryons determined from the 3He data is in excellent agreement with the densities calculated from other cosmological probes. The previous conflict is resolved because most solar-mass stars do not produce enough 3He to enrich the interstellar medium significantly.

  16. SU-E-T-625: Use and Choice of Ionization Chambers for the Commissioning of Flattened and Flattening-Filter-Free Photon Beams: Determination of Recombination Correction Factor (ks)

    SciTech Connect

    Stucchi, C; Mongioj, V; Carrara, M; Pignoli, E; Bonfantini, F; Bresolin, A

    2014-06-15

    Purpose: To evaluate the recombination effect for some ionization chambers to be used for linacs commissioning for Flattened Filter (FF) and Flattening Filter Free (FFF) photon beams. Methods: A Varian TrueBeam linac with five photon beams was used: 6, 10 and 15 MV FF and 6 and 10 MV FFF. Measurements were performed in a water tank and in a plastic water phantom with different chambers: a mini-ion chamber (IC CC01, IBA), a plane-parallel ion chamber (IC PPC05, IBA) and two Farmer chambers (NE2581 and FPC05-IBA). Measurement conditions were Source- Surface Distance of 100 cm, two field sizes (10x10 and 40x40 cm2) and five depths (1cm, maximum buildup, 5cm, 10cm and 20cm). The ion recombination factors (kS), obtained from the Jaffe's plots (voltage interval 50-400 V), were evaluated at the recommended operating voltage of +300V. Results: Dose Per Pulse (DPP) at dmax was 0.4 mGy/pulse for FF beams, 1.0 mGy/pulse and 1.9 mGy/pulse for 6MV and 10 MV FFF beams respectively. For all measurement conditions, kS ranged between 0.996 and 0.999 for IC PPC05, 0.997 and 1.008 for IC CC01. For the FPC05 IBA Farmer IC, kS varied from 1.001 to 1.011 for FF beams, from 1.004 to 1.015 for 6 MV FFF and from 1.009 to 1.025 for 10 MV FFF. Whereas, for NE2581 IC the values ranged from 1.002 to 1.009 for all energy beams and measurement conditions. Conclusion: kS depends on the chamber volume and the DPP, which in turn depends on energy beam but is independent of dose rate. Ion chambers with small active volume can be reliably used for dosimetry of FF and FFF beams even without kS correction. On the contrary, for absolute dosimetry of FFF beams by Farmer ICs it is necessary to evaluate and apply the kS correction. Partially supported by Lega Italiana Lotta contro i Tumori (LILT)

  17. The heavy ion composition in 3HE-rich solar flares

    NASA Technical Reports Server (NTRS)

    Mason, G. M.; Reames, D. V.; Hovestadt, D.; Vonrosenvinge, T. T.

    1985-01-01

    The 3He-rich flares show a tendency to be enriched in heavy ions, and that this enrichment covers the charge range through Fe. The discovery of this association was responsible, in part, for the discarding of 3He enrichment models which involved spallation or thermonuclear reactions, since such models were unable to produce heavy nuclei enhancement. Results of a survey of heavy nucleus abundances observed in 66 3He-rich flares which occurred over the period October 1978 to June 1982 are presented.

  18. Polarized {sup 3}He{sup −} ion source with hyperfine state selection

    SciTech Connect

    Dudnikov, V.; Morozov, V.; Dudnikov, A.

    2015-04-08

    High beam polarization is essential to the scientific productivity of a collider. Polarized {sup 3}He ions are an essential part of the nuclear physics programs at existing and future ion-ion and electron-ion colliders such as BNL's RHIC and eRHIC and JLab's ELIC. Ion sources with performance exceeding that achieved today are a key requirement for the development of these next generation high-luminosity high-polarization colliders. The development of high-intensity high-brightness arc-discharge ion sources at the Budker Institute of Nuclear Physics (BINP) has opened up an opportunity for realization of a new type of a polarized {sup 3}He{sup −} ion source. This report discusses a polarized {sup 3}He{sup −} ion source based on the large difference of extra-electron auto-detachment lifetimes of the different {sup 3}He{sup −} ion hyperfine states. The highest momentum state of 5/2 has the largest lifetime of τ ∼ 350 µs while the lower momentum states have lifetimes of τ ~ 10 µs. By producing {sup 3}He{sup −} ion beam composed of only the |5/2, ±5/2> hyperfine states and then quenching one of the states by an RF resonant field, {sup 3}He{sup −} beam polarization of 90% can be achieved. Such a method of polarized {sup 3}He{sup −} production has been considered before; however, due to low intensities of the He{sup +} ion sources existing at that time, it was not possible to produce any interesting intensity of polarized {sup 3}He{sup −} ions. The high-brightness arc-discharge ion source developed at BINP can produce a high-brightness {sup 3}He{sup +} beam with an intensity of up to 2 A allowing for selection of up to ∼1-4 mA of {sup 3}He{sup −} ions with ∼90% polarization. The high gas efficiency of an arc-discharge source is important due to the high cost of {sup 3}He gas. Some features of such a PIS as well as prototype designs are considered. An integrated {sup 3}He{sup −} ion source design providing high beam polarization could be

  19. Recent advances in spin-exchange pumped polarized 3He target technology

    NASA Astrophysics Data System (ADS)

    Smith, T. B.; Chupp, T. E.; Coulter, K. P.; Welsh, R. C.

    1998-02-01

    We have produced long lifetime 3He spin-exchange cells from Corning 7056 glass. The lifetimes of single cells have approached the 3He 3He bulk-limited lifetime (250 h at a density of 8 × 10 19 cm -3, (3 amagats)). Corning 7056 glass has the advantage of being a much easier glass for the glassblower to work, allowing for more complex cell designs. In our experiments at Michigan and at SLAC, we have implemented laser diode arrays for spin-exchange optical pumping. In particular, for experiment E154 at SLAC, we achieved high polarizations in high-density 3He targets using laser diode arrays.

  20. Triple oxygen isotopic composition of the high-3He/4He mantle

    NASA Astrophysics Data System (ADS)

    Starkey, N. A.; Jackson, C. R. M.; Greenwood, R. C.; Parman, S.; Franchi, I. A.; Jackson, M.; Fitton, J. G.; Stuart, F. M.; Kurz, M.; Larsen, L. M.

    2016-03-01

    Measurements of Xe isotope ratios in ocean island basalts (OIB) suggest that Earth's mantle accreted heterogeneously, and that compositional remnants of accretion are sampled by modern, high-3He/4He OIB associated with the Icelandic and Samoan plumes. If so, the high-3He/4He source may also have a distinct oxygen isotopic composition from the rest of the mantle. Here, we test if the major elements of the high-3He/4He source preserve any evidence of heterogeneous accretion using measurements of three oxygen isotopes on olivine from a variety of high-3He/4He OIB locations. To high precision, the Δ17O value of high-3He/4He olivines from Hawaii, Pitcairn, Baffin Island and Samoa, are indistinguishable from bulk mantle olivine (Δ17OBulk Mantle - Δ17OHigh 3He/4He olivine = -0.002 ± 0.004 (2 × SEM)‰). Thus, there is no resolvable oxygen isotope evidence for heterogeneous accretion in the high-3He/4He source. Modelling of mixing processes indicates that if an early-forming, oxygen-isotope distinct mantle did exist, either the anomaly was extremely small, or the anomaly was homogenised away by later mantle convection. The δ18O values of olivine with the highest 3He/4He ratios from a variety of OIB locations have a relatively uniform composition (∼5‰). This composition is intermediate to values associated with the depleted MORB mantle and the average mantle. Similarly, δ18O values of olivine from high-3He/4He OIB correlate with radiogenic isotope ratios of He, Sr, and Nd. Combined, this suggests that magmatic oxygen is sourced from the same mantle as other, more incompatible elements and that the intermediate δ18O value is a feature of the high-3He/4He mantle source. The processes responsible for the δ18O signature of high-3He/4He mantle are not certain, but δ18O-87Sr/86Sr correlations indicate that it may be connected to a predominance of a HIMU-like (high U/Pb) component or other moderate δ18O components recycled into the high-3He/4He source.

  1. Recent advances of polarized {sup 3}He target at Jefferson Lab

    SciTech Connect

    Qiang Yi

    2011-10-24

    Polarized {sup 3}He targets have been widely used in nuclear and particle physics experiments to study neutron structure in the spin degree of freedom, as most of the {sup 3}He spin is carried by the unpaired neutron. The Spin-Exchange Optical Pumping (SEOP) process is used in Jefferson Lab Hall A to polarize its {sup 3}He target. In recent years, both the performance and corresponding polarimetry of such a target have been greatly improved. Several experiments recently carried out in Hall A have achieved record high figure of merit using this target.

  2. Investigation of the {sup 3}He wave function by quasifree scattering

    SciTech Connect

    Jones, C.E.; Hansen, J.O.; Bloch, C.

    1995-08-01

    The analysis of the data from the CE25 experiment at IUCF, which measured the target and beam analyzing powers and the spin correlation parameter in {sup 3}He(p,2p) and {sup 3}He(p,pn) quasielastic scattering, is nearing completion. At low missing momentum, the extracted polarization of the neutron and proton in {sup 3}He are consistent with Faddeev calculations. Two papers, one reporting the physics results and one describing the experiment, were published. The data from this experiment indicates that for q {>=} 500 MeV/c the plane wave impulse approximation is valid.

  3. Bakeout Chamber Within Vacuum Chamber

    NASA Technical Reports Server (NTRS)

    Taylor, Daniel M.; Soules, David M.; Barengoltz, Jack B.

    1995-01-01

    Vacuum-bakeout apparatus for decontaminating and measuring outgassing from pieces of equipment constructed by mounting bakeout chamber within conventional vacuum chamber. Upgrade cost effective: fabrication and installation of bakeout chamber simple, installation performed quickly and without major changes in older vacuum chamber, and provides quantitative data on outgassing from pieces of equipment placed in bakeout chamber.

  4. Recent advancements of wide-angle polarization analysis with 3He neutron spin filters

    NASA Astrophysics Data System (ADS)

    Chen, W. C.; Gentile, T. R.; Ye, Q.; Kirchhoff, A.; Watson, S. M.; Rodriguez-Rivera, J. A.; Qiu, Y.; Broholm, C.

    2016-09-01

    Wide-angle polarization analysis with polarized 3He based neutron spin filters (NSFs) has recently been employed on the Multi-Axis Crystal Spectrometer (MACS) at the National Institute of Standards and Technology Center for Neutron Research (NCNR). Over the past several years, the apparatus has undergone many upgrades to address the fundamental requirements for wide angle polarization analysis using spin exchange optical pumping based 3He NSFs. In this paper, we report substantial improvements in the on-beam-line performance of the apparatus and progress toward routine user capability. We discuss new standard samples used for 3He NSF characterization and the flipping ratio measurement on MACS. We further discuss the management of stray magnetic fields produced by operation of superconducting magnets on the MACS instrument, which can significantly reduce the 3He polarization relaxation time. Finally, we present the results of recent development of horseshoe-shaped wide angle cells.

  5. Progress Towards the Detection of Faraday Rotation on Spin Polarized 3He

    NASA Astrophysics Data System (ADS)

    Abney, Josh; Broering, Mark; Korsch, Wolfgang

    2016-03-01

    Off-resonance Faraday rotation can offer a new method to monitor the nuclear spin polarization of a dense 3He target and gain access to new information about the magnetic polarizability of the 3He nucleus. The interaction of the polarization state of light with the nuclear spin of the helium atom is very weak and has never been detected. A sensitive triple modulation technique has been developed which can detect the expected rotation angle on the order of 100 nrad. Once a Faraday rotation signal is observed, the next step is to separate the magnetic and electric contributions to the rotation by utilizing their different frequency dependencies. Recent studies involved optimizing several parameters which impact 3He target polarization. Progress towards detecting nuclear spin optical rotation on 3He will be reported. This research is supported by DOE Grant DE-FG02-99ER41101.

  6. The enigmatic high 3He/4He mantle: Characteristics and Origins. (Invited)

    NASA Astrophysics Data System (ADS)

    Jackson, M. G.

    2009-12-01

    Noble gas isotopes measured in some oceanic island basalts (OIBs) exhibit ratios that are associated with the solar wind and the atmosphere of Jupiter, suggesting that the lavas tap portions of an ancient reservoir that still resides in the Earth’s mantle [e.g., 1]. High 3He/4He, as seen in the sources of some OIBs, can therefore serve as a powerful indicator for tracing ancient signatures that have survived in the Earth’s interior. However, the storage mechanisms and reasons for long-term survival of the high 3He/4He signature in the Earth’s convecting mantle are poorly understood. One important observation is that high 3He/4He lavas have 143Nd/144Nd ratios that are higher than chondrites, suggesting that they were derived from a mantle reservoir that suffered ancient depletion. The association of primitive, high 3He/4He with depleted, nonprimitive 143Nd/144Nd in OIBs is not straightforward and a number of models have been developed to resolve this apparent complexity [e.g., 2,3,4,5,6]. It is also becoming apparent that the high 3He/4He reservoir is heterogeneous. High 3He/4He (>30 times atmospheric) lavas from Hawaii, Iceland and Galapagos have more depleted 143Nd/144Nd (0.51294-0.51297) than lavas with similarly high 3He/4He from Samoa (0.51283). In fact, the highest 3He/4He sample from each southern hemisphere high 3He/4He hotspot (FOZO-A, austral) exhibits lower 143Nd/144Nd ratios their northern hemisphere (FOZO-B, boreal) counterparts. The mechanism for this separation is unknown, but it is similar in spatial scale to the DUPAL anomaly, a globe-encircling feature of isotopic enrichment observed primarily in southern hemisphere OIBs. With the exception of Baffin Is. picrites [7], high 3He/4He OIBs also exhibit evidence for Ti, Ta, and Nb (TITAN) enrichment relative to low 3He/4He OIBs. This was interpreted as the result of addition of refractory, rutile-bearing eclogite to a peridotitic high 3He/4He reservoir [8]. This hypothesis is supported by the

  7. Sol-gel coatings for high pressure polarized ^3He nuclear targets

    NASA Astrophysics Data System (ADS)

    Deur, Alexandre; Cates, Gordon D.; Chaput, Julien; Singh, Jaideep; Tobias, William A.

    2001-11-01

    Sol-gel coated glass cells have been shown to exhibit longitudinal lifetimes T1 in excess of 350 hours for ^3He that is polarized by spin-exchange optical pumping.( Ming F. Hsu shape et al, Appl. Phys. Lett.) series 77 (2000) 2069. The sol-gel technique was designed to minimize spin-relaxation due to wall collisions so that only dipole-dipole interactions between colliding ^3He atoms dominate in the relaxation process. Until now, sol-gel technology has not been applied to high pressure ^3He gas targets used in nuclear scattering experiments. Latest developments on incorporating the sol-gel technique in the production of these ^3He targets will be presented.

  8. The Triple Oxygen Isotopic Composition of High 3He/4He Mantle

    NASA Astrophysics Data System (ADS)

    Jackson, C.; Parman, S. W.; Starkey, N.; Greenwood, R.; Franchi, I.; Jackson, M. G.; Fitton, J. G.; Stewart, F. M.; Larsen, L. M.

    2015-12-01

    Measurements of Xe isotope ratios in ocean island basalts (OIB) suggest that Earth's mantle accreted heterogeneously, and that compositional remnants of accretion are sampled by modern, high-3He/4He OIB associated with the Icelandic and Samoan plumes [1]. If so, the high-3He/4He source may also have a distinct oxygen isotopic composition from the rest of the mantle. Here, we test if the major elements of the high-3He/4He source preserve any evidence of heterogeneous accretion using measurements of three oxygen isotopes on olivine from a variety of high-3He/4He OIB locations. To high precision, the ∆17O value of high-3He/4He olivines from Hawaii, Pitcairn, Baffin Island and Samoa, are indistinguishable from bulk mantle olivine (Δ17OBulk Mantle - Δ17OHigh 3He/4He olivine = -0.002 ± 0.004 (2 x SEM) ‰). Thus, there is no resolvable oxygen isotope evidence for heterogeneous accretion in the high-3He/4He source. Modelling of mixing processes indicates that if an early-forming, oxygen-isotope distinct mantle did exist, either the anomaly was extremely small, or the anomaly was homogenised away by later mantle convection. The δ18O values of olivine with the highest 3He/4He ratios from a variety of OIB locations have a relatively uniform composition (~5 ‰). This composition is intermediate to values associated with the depleted MORB mantle and the average mantle. Similarly, δ18O values of olivine from high-3He/4He OIB correlate with radiogenic isotope ratios of He, Sr, and Nd. Combined, this suggests that oxygen remains coupled to the more incompatible elements during melt production and migration and that the intermediate δ18O value is a feature of the mantle source. The processes responsible for the δ18O signature of high-3He/4He mantle are not certain, but δ18O-87Sr/86Sr correlations indicate that it may be connected to a predominance of a HIMU-like (high U/Pb) component or other moderate δ18O components recycled into the high-3He/4He source. [1] S

  9. Preservation of extraterrestrial 3He in 480-Ma-old marine limestones.

    PubMed

    Patterson, D B; Farley, K A; Schmitz, B

    1998-11-01

    We have measured the helium abundance and isotopic composition of a suite of Lower Ordovician marine limestones and associated fossil meteorites from Kinnekulle, Sweden. Limestone 3He/4He ratios as high as 11.5 times the atmospheric value in fused samples and up to 23 times atmospheric in a single step-heat fraction indicate the presence of extraterrestrial helium, and demonstrate that at least a fraction of the extraterrestrial 3He carried by interplanetary dust particles must be retained against diffusive and diagenetic losses for up to 480 Ma. The carrier phase has not been identified but is not magnetic. Extrapolation of high-temperature 3He diffusivities in these sediments is consistent with strong retention of extraterrestrial 3He under ambient Earth-surface conditions. Combination of the observed helium concentrations with sedimentation rates estimated from conodont biostratigraphy suggest that the flux of extraterrestrial 3He in the Early Ordovician was about 0.5 x 10(-12) cm3 STP cm-2 ka-1, ignoring potential post-deposition helium loss. This value is indistinguishable from the average 3He flux estimated for the Cenozoic Era. In contrast, previous studies of fossil meteorites, Ir abundances, and Os isotopic ratios in the limestone suggest that the total accretion rate of extraterrestrial material during the studied interval was at least an order of magnitude higher than the Cenozoic average. This disparity may reflect significant post-depositional loss of 3He from IDPs within these old limestones; if so, the match between the Ordovician flux and the Cenozoic average would be fortuitous. Alternatively, the size distribution of infalling objects during the Early Ordovician may have been enriched only in extraterrestrial material too large to retain 3He during atmospheric entry heating (> approximately 30 micrometers). The fossil meteorites themselves also preserve extraterrestrial helium. Meteorite 3He concentrations of 2 to 9 x 10(-12) cm3 STP g-1 are

  10. The mean ionic charge of silicon in 3HE-rich solar flares

    NASA Technical Reports Server (NTRS)

    Luhn, A.; Klecker, B.; Hovestadt, E.; Moebius, E.

    1985-01-01

    Mean ionic charge of iron in 3He-rich solar flares and the average mean charge of Silicon for 23 #He-rich periods during the time interval from September 1978 to October 1979 were determined. It is indicated that the value of the mean charge state of Silicon is higher than the normal flare average by approximately 3 units and in perticular it is higher then the value predicted by resonant heating models for 3He-rich solar flares.

  11. High-efficiency microstructured semiconductor neutron detectors for direct 3He replacement

    NASA Astrophysics Data System (ADS)

    Fronk, R. G.; Bellinger, S. L.; Henson, L. C.; Huddleston, D. E.; Ochs, T. R.; Sobering, T. J.; McGregor, D. S.

    2015-04-01

    High-efficiency Microstructured Semiconductor Neutron Detectors (MSNDs) have been tiled and arranged in a cylindrical form factor in order to serve as a direct replacement to aging and increasingly expensive 3He gas-filled proportional neutron detectors. Two 6-in long by 2-in diameter cylinders were constructed and populated with MSNDs which were then directly compared to a 4 atm Reuter Stokes 3He detector of the same dimensions. The Generation 1 MSND-based 3Helium-Replacement (HeRep Mk I) device contained sixty-four 1-cm2 active-area MSNDs, each with an intrinsic neutron detection efficiency of approximately 7%. A Generation 2 device (the HeRep Mk II) was populated with thirty 4-cm2 active-area MSNDs, with an intrinsic thermal neutron detection efficiency of approximately 30%. The MSNDs of each HeRep were integrated to count as a single device. The 3He proportional counter and the HeRep devices were tested while encased in a cylinder of high-density polyethylene measuring a total of 6-in by 9-in. The 3He counter and the HeRep Mk II were each placed 1 m from a 54-ng 252Cf source and tested for efficiency. The 3He proportional counter had a net count rate of 17.13±0.10 cps at 1 m. The HeRep Mk II device had a net count rate of 17.60±0.10 cps, amounting to 102.71±2.65% of the 3He gas counter while inside of the moderator. Outside of moderator, the 3He tube had a count rate of 3.35±0.05 cps and the HeRep Mk II device reported 3.19±05, amounting to 95.15±9.04% of the 3He neutron detector.

  12. Meson exchange currents for nuclear muon capture by {sup 3}He

    SciTech Connect

    Congleton, J.G.; Truhlik, E.

    1995-05-10

    We have calculated exchange corrections for nuclear muon capture by {sup 3}He using the hard pion method for the currents and wavefunctions for {sup 3}He and {sup 3}H found by the coupled rearrangement channel method. The result for the rate (triton asymmetry) has an uncertainty of 3% (1%) due mainly to the uncertainty in the value of {ital f}{sub {pi}{ital N}{Delta}} (various factors). {copyright} {ital 1995} {ital American} {ital Institute} {ital of} {ital Physics}.

  13. SANS study of phase separation in solid {sup 3}He-{sup 4}He

    SciTech Connect

    Koster, J.P.; Nagler, S.E.; Adams, E.D.; Wignall, G.D.

    1994-12-31

    Small angle neutron scattering has been used to study phase separation in a quantum alloy, solid {sup 3}He{sub x}-{sup 4}He{sub 1{minus}x}. The onset of phase separation is marked by a dramatic increase in the measured scattering. A simple interpretation of the results suggests that the late-stage phase separation kinetics are dominated by an increase in the concentration of {sup 3}He atoms in preexisting precipitate regions.

  14. Distal airways in humans: dynamic hyperpolarized 3He MR imaging--feasibility

    NASA Technical Reports Server (NTRS)

    Tooker, Angela C.; Hong, Kwan Soo; McKinstry, Erin L.; Costello, Philip; Jolesz, Ferenc A.; Albert, Mitchell S.

    2003-01-01

    Dynamic hyperpolarized helium 3 (3He) magnetic resonance (MR) imaging of the human airways is achieved by using a fast gradient-echo pulse sequence during inhalation. The resulting dynamic images show differential contrast enhancement of both distal airways and the lung periphery, unlike static hyperpolarized 3He MR images on which only the lung periphery is seen. With this technique, up to seventh-generation airway branching can be visualized. Copyright RSNA, 2003.

  15. Transport of polarized 3He for the nEDM experiment at the SNS

    NASA Astrophysics Data System (ADS)

    Rao, Thomas; Beck, Douglas; Koivuniemi, Jaakko; Silvera, Ike; Williamson, Steven; Yao, Weijun; nEDM Collaboration

    2016-09-01

    The neutron electric dipole moment (nEDM) experiment at the ORNL SNS aims to determine the neutron's electric dipole moment to an accuracy of 5.4 x 10-28 e cm by measuring the Lamor precession of neutrons using the spin dependent reaction n +3He =>p +3H +764KeV. In the experiment polarized 3He is injected into a free surface of 4He, and then brought to the measurement cell and removed once it depolarizes. The proposed transport method for the 3He, the heat flush mechanism, must be tested. In the heat flush mechanism a thermal gradient along a long pipe, generates phonons whose collisions with 3He, drives 3He transport to the cold end of the pipe. Tests of the heat flush mechanism by measuring the change in 3He concentration at the cold end of a long pipe, using a capacitive pressure sensor, are underway at Harvard University. Work supported in part by NSF Grants PHY-1440011 and PHY-1506416.

  16. Primordial 3He in South Atlantic deep waters from sources on the Mid-Atlantic Ridge

    NASA Astrophysics Data System (ADS)

    Rüth, Christine; Well, Roland; Roether, Wolfgang

    2000-06-01

    Helium isotope data from three zonal WOCE sections (11°S, 19°S and 30°S) in the South Atlantic are presented. Among other features we find a distinct δ 3He-maximum above the Mid-Atlantic Ridge (MAR) at all three latitudes. Using a hydrographic multiparameter analysis, we separate 3He emanating from the MAR from the large-scale 3He background. To our knowledge, this is the first confirmation of input of primordial 3He at the MAR in the South Atlantic. The source appears to be weak compared with the Pacific sources, causing 3He elevations (relative to background values) of only 2-3% directly above the MAR. This exceeds by several times the statistical and systematic data uncertainties, which amount to 0.35% each, so that detailed contouring of the MAR-derived 3He is possible. At 30°S and 11°S, a significant signal extends westward over at least 2000 km, whereas at 19°S the signal is more confined to the ridge area. The westward extensions indicate westward flow at depths near the ridge crest elevation, contradicting flow directions deduced previously by Reid (1989).

  17. Compressing Spin-Polarized 3He With a Modified Diaphragm Pump

    PubMed Central

    Gentile, T. R.; Rich, D. R.; Thompson, A. K.; Snow, W. M.; Jones, G. L.

    2001-01-01

    Nuclear spin-polarized 3He gas at pressures on the order of 100 kPa (1 bar) are required for several applications, such as neutron spin filters and magnetic resonance imaging. The metastability-exchange optical pumping (MEOP) method for polarizing 3He gas can rapidly produce highly polarized gas, but the best results are obtained at much lower pressure (~0.1 kPa). We describe a compact compression apparatus for polarized gas that is based on a modified commercial diaphragm pump. The gas is polarized by MEOP at a typical pressure of 0.25 kPa (2.5 mbar), and compressed into a storage cell at a typical pressure of 100 kPa. In the storage cell, we have obtained 20 % to 35 % 3He polarization using pure 3He gas and 35 % to 50 % 3He polarization using 3He-4He mixtures. By maintaining the storage cell at liquid nitrogen temperature during compression, the density has been increased by a factor of four. PMID:27500044

  18. An Update on 3He Correlation Function Research for the SNS nEDM collaboration

    NASA Astrophysics Data System (ADS)

    Reid, Austin; Golub, Robert; Dipert, Robert

    2016-09-01

    In the 65 years since Ramsey's null result for the neutron's permanent electric dipole moment (nEDM), techniques have become increasingly sensitive, establishing the present upper limit of 3 ×10-26 e .cm . This value was limited by an unexpected source of error: a freqency shift with linear dependence on the electric field colloquially called a false EDM. The next generation nEDM sensing apparatus being developed for the Spallation Neutron Source at Oak Ridge National Laboratory uses a 3He comagenetometer in a pure helium-II bath. The false EDM in 3He may be related to the 3He's position autocorrelation function, which in turn is accessible by a detailed study of T1 decay in hyperpolarized 3He. Existing measurements of this system were limited by temperature, noise, and 3He concentration. Dramatic improvements have been made on all three fronts by improving the thermal connection between the measurment cell and the dilution refrigerator, by adding additional shielding and a SQUID package, and by developing a MEOP 3He polarization system. Data collection is underway. This material is based upon work supported by the U.S. Department of Energy, Office of Science, Office of Nuclear Physics, under Award Number DE-FG02-97ER41042.

  19. Pomeranchuk cell for hyperpolarized 3He based on the brute force method

    NASA Astrophysics Data System (ADS)

    Makino, Seiji; Tanaka, Masayoshi; Ueda, Kunihiro; Fujiwara, Mamoru; Fujimura, Hisako; Yosoi, Masaru; Ohta, Takeshi; Frossati, Giorgio; de Waard, Arlette; Rouille, Gerard

    2014-09-01

    MRI (Magnetic Resonance Imaging) has been used for the medical diagnosis as a radiation-free imaging equipment. Since the proton has been mainly used for medical MRI, usefulness has been rather restrictive. As an example for expanding the range of applicability, MRI with hyperpolarized 3He gas has been used for the lung disease. Here, ``hyperpolarized'' means ``polarized higher than the thermal equilibrium polarization.'' For producing a large amount of hyperpolarized 3He gas at a time, we have been developing a hyperpolarization technique based on the brute force method which uses an ultralow temperature of a few mK and a strong magnetic field around 17 T in combination with the principle of the Pomeranchuk cooling. The Pomeranchuk cell made with non-metallic materials of small heat capacity is attached to the 3He/4He dilution refrigerator using a sintered silver allowing large heat conduction. After the sensors to monitor the temperature and pressure of 3He are calibrated and the Pomeranchuk cell is constructed, the system is tested. Then, the solidification of 3He and the measurement of NMR (Nuclear Magnetic Resonance) signals of 3He under the magnetic field of 17 T are carried out. The current status is reported in this talk.

  20. Terrestrial cosmogenic 3He: where are we 30 years after its discovery?

    NASA Astrophysics Data System (ADS)

    Blard, Pierre-Henri; Pik, Raphaël; Farley, Kenneth A.; Lavé, Jérôme; Marrocchi, Yves

    2016-04-01

    It is now 30 years since cosmogenic 3He has been detected for the first time in a terrestrial sample (Kurz, 1986). 3He is now a widely used geochemical tool in many fields of Earth sciences: volcanology, tectonics, paleoclimatology. 3He has the advantage to have a high "production rate" to "detection limit" ratio, allowing surfaces as young as hundred of years to be dated. Although its nuclear stability implies several limitations, it moreover represents a useful alternative to 10Be in mafic environments. This contribution is a review of the progresses that have been accomplished since this discovery, and discuss strategies to improve both the accuracy and the precision of this geochronometer. 1) Measurement of cosmogenic 3He Correction of magmatic 3He. To estimate the non-cosmogenic magmatic 3He, Kurz (1986) invented a two steps method involving crushing of phenocrysts (to analyze the isotopic ratio of the magmatic component), followed by a subsequent melting of the sample, to extract the remaining components, including the cosmogenic 3He: 3Hec = 3Hemelt -4Hemelt x (3He/4He)magmatic (1) Several studies suggested that the preliminary crushing may induce a loss of cosmogenic 3He (Hilton et al., 1993; Yokochi et al., 2005; Blard et al., 2006), implying an underestimate of the cosmogenic 3He measurement. However, subsequent work did not replicate these observations (Blard et al., 2008; Goerhing et al., 2010), suggesting an influence of the used apparatus. An isochron method (by directly melting several phenocrysts aliquots) is an alternative to avoid the preliminary crushing step (Blard and Pik, 2008). Atmospheric contamination. Protin et al. (in press) provides robust evidences for a large and irreversible contamination of atmospheric helium on silicate surfaces. This unexpected behavior may reconcile the contrasted observations about the amplitude of crushing loss. This undesirable atmospheric contamination is negligible if grain fractions smaller than 150 mm are

  1. An important source of 4He (and 3He) in diamonds

    NASA Astrophysics Data System (ADS)

    Lal, D.

    1989-12-01

    A large data base has recently accumulated on the concentrations of helium isotopes in diamonds mined from various regions. It was noted earlier (Ozima et al. (1985) [1]; Lal et al. (1989) [2]) that the frequency distribution of the 4He concentrations is a fairly narrow one, whereas that of 3He concentrations is a broad one with no pronounced peaks. The ratios 3He/ 4He , on the other hand show a broad maximum around 2 R a ( R a equals atmospheric 3He/ 4He ratio, = 1.40 × 10 -6) with a slow decrease over two orders of magnitude on either side. Does this imply that the diamonds sample a wide variety of helium reservoirs having a range of 3He/ 4He ratios but somehow attain similar 4He concentrations? We propose that in a majority of the diamonds studied, 4He is primarily due to implantation of radiogenic alpha particles from the host material after emplacement in the crust, usually kimberlite, and that the concentrations of 4He in diamonds often get appreciably altered by this process. Thus the 4He trapped in the diamond at the time of its crystallization is usually overwhelmed by the implanted helium and the measured 3He/ 4He ratios do not generally correspond to any "sources" in the mantle. However, the implanted 4He resides in the outer 16 μm of the diamond, and the intrinsic 4He and 3He/ 4He ratios in the diamond can be studied if its outer layers are removed. The wider implications of diamond being the "target" material for nuclear reaction products from the host material are discussed. Radiogenic 3He produced in the host material is also implanted in the diamond, but this contribution is small on a gross basis. However, since the depth of implantation of 3He is greater than that of 4He, some of the very high 3He/ 4He ratios observed in diamonds could be due to the "implantation" of radiogenic 3He. The radiogenic reactions in the host material can also contribute to appreciable 21Ne in diamonds.

  2. Minority and mode conversion heating in (3He)-H JET plasmas

    NASA Astrophysics Data System (ADS)

    Van Eester, D.; Lerche, E.; Johnson, T. J.; Hellsten, T.; Ongena, J.; Mayoral, M.-L.; Frigione, D.; Sozzi, C.; Calabro, G.; Lennholm, M.; Beaumont, P.; Blackman, T.; Brennan, D.; Brett, A.; Cecconello, M.; Coffey, I.; Coyne, A.; Crombe, K.; Czarnecka, A.; Felton, R.; Gatu Johnson, M.; Giroud, C.; Gorini, G.; Hellesen, C.; Jacquet, P.; Kazakov, Ye; Kiptily, V.; Knipe, S.; Krasilnikov, A.; Lin, Y.; Maslov, M.; Monakhov, I.; Noble, C.; Nocente, M.; Pangioni, L.; Proverbio, I.; Stamp, M.; Studholme, W.; Tardocchi, M.; Versloot, T. W.; Vdovin, V.; Whitehurst, A.; Wooldridge, E.; Zoita, V.; EFDA Contributors, JET

    2012-07-01

    Radio frequency (RF) heating experiments have recently been conducted in JET (3He)-H plasmas. This type of plasmas will be used in ITER's non-activated operation phase. Whereas a companion paper in this same PPCF issue will discuss the RF heating scenario's at half the nominal magnetic field, this paper documents the heating performance in (3He)-H plasmas at full field, with fundamental cyclotron heating of 3He as the only possible ion heating scheme in view of the foreseen ITER antenna frequency bandwidth. Dominant electron heating with global heating efficiencies between 30% and 70% depending on the 3He concentration were observed and mode conversion (MC) heating proved to be as efficient as 3He minority heating. The unwanted presence of both 4He and D in the discharges gave rise to 2 MC layers rather than a single one. This together with the fact that the location of the high-field side fast wave (FW) cutoff is a sensitive function of the parallel wave number and that one of the locations of the wave confluences critically depends on the 3He concentration made the interpretation of the results, although more complex, very interesting: three regimes could be distinguished as a function of X[3He]: (i) a regime at low concentration (X[3He] < 1.8%) at which ion cyclotron resonance frequency (ICRF) heating is efficient, (ii) a regime at intermediate concentrations (1.8 < X[3He] < 5%) in which the RF performance is degrading and ultimately becoming very poor, and finally (iii) a good heating regime at 3He concentrations beyond 6%. In this latter regime, the heating efficiency did not critically depend on the actual concentration while at lower concentrations (X[3He] < 4%) a bigger excursion in heating efficiency is observed and the estimates differ somewhat from shot to shot, also depending on whether local or global signals are chosen for the analysis. The different dynamics at the various concentrations can be traced back to the presence of 2 MC layers and their

  3. Photodisintegration of /sup 3/H and /sup 3/He. [Threshold to 25 MeV

    SciTech Connect

    Faul, D.D.

    1980-09-01

    The photoneutron cross sections for /sup 3/H and /sup 3/He have been measured from threshold to approx. 25 MeV with monoenergetic photons from the annihilation in flight of fast positrons at the LLL Electron-Positron Linear Accelerator facility. These reactions include the two-body breakup of /sup 3/H and the three-body breakup of both /sup 3/H and /sup 3/He; these measurements for /sup 3/H are the first to span the energy region across the peaks of the cross sections. An efficient BF/sub 3/-tube-and-paraffin neutron detector and high-pressure gaseous samples of several moles each (the activity of the /sup 3/H sample was approx. 200,000 Ci) were employed in these measurements. Measurements on /sup 16/O and /sup 2/H also were performed to verify the absolute cross-section scale. The results, when compared with each other and with results for the two-body breakup cross section for /sup 3/He from the literature, show that the two-body breakup cross sections for /sup 3/H and /sup 3/He have nearly the same shape, but the one for /sup 3/He lies lower in magnitude; the three-body breakup cross section for /sup 3/He lies higher in magnitude and is broader in the peak region and also rises less sharply from threshold than that for /sup 3/H; and these measured differences between the cross sections for the breakup modes largely compensate in their sum, so that the total photon absorption cross sections for /sup 3/H and /sup 3/He are nearly the same in both size and shape at energies near and above their peaks. Theoretical results from the literature disagree with the experimental results to a certain extent over the entire photon-energy region for which the photoneutron cross sections were measured. 50 figures, 7 tables.

  4. Association of 3He-Rich Solar Energetic Particles with Large-scale Coronal Waves

    NASA Astrophysics Data System (ADS)

    Bučík, Radoslav; Innes, Davina E.; Mason, Glenn M.; Wiedenbeck, Mark E.

    2016-12-01

    Small, 3He-rich solar energetic particle (SEP) events have been commonly associated with extreme-ultraviolet (EUV) jets and narrow coronal mass ejections (CMEs) that are believed to be the signatures of magnetic reconnection, involving field lines open to interplanetary space. The elemental and isotopic fractionation in these events are thought to be caused by processes confined to the flare sites. In this study, we identify 32 3He-rich SEP events observed by the Advanced Composition Explorer, near the Earth, during the solar minimum period 2007-2010, and we examine their solar sources with the high resolution Solar Terrestrial Relations Observatory (STEREO) EUV images. Leading the Earth, STEREO-A has provided, for the first time, a direct view on 3He-rich flares, which are generally located on the Sun’s western hemisphere. Surprisingly, we find that about half of the 3He-rich SEP events in this survey are associated with large-scale EUV coronal waves. An examination of the wave front propagation, the source-flare distribution, and the coronal magnetic field connections suggests that the EUV waves may affect the injection of 3He-rich SEPs into interplanetary space.

  5. ^3He Polarization by Rb Spin Exchange in a Multistage System

    NASA Astrophysics Data System (ADS)

    Coulter, K. P.; Chupp, T. E.; Smith, T. B.; Welsh, R. C.; Zerger, J. N.

    1999-10-01

    Polarization of ^3He by spin exchange with optically pumped Rb has benefited greatly from the use of high powered laser diode arrays. Efficient use of these lasers requires operation of cells with high ^3He densities to match better the pressure broadened Rb absorption line to the wide laser spectral profile. However, lower delivery pressures are often required. For example, for low energy neutron spin filters the optimum ^3He thickness (for practical polarizations) would produce impractically thin cells. A multistage system is practical for applications requiring high ^3He polarization delivered at variable pressure because the optical pumping stage can be separated from the delivery/refilling stages. Additionally, operation can be improved by choosing the appropriate glass for each stage. We have constructed a multistage system that consists of a 70 cc pump cell (Corning 7056 glass), a transition region (Pyrex Glass), and a 350 cc receiving cell (Cs-coated Fused Silica). The cells are connected using commercial Viton-rubber o-ring sealed Pyrex glass valves and ball and socket joints. The transition region is connected to a vacuum pump and gas fill system so that cells may be refilled in situ. Both pump cells and receiving cells have exhibited intrinsic ^3He relaxation times of >35 hours. We will report on tests of this prototype system.

  6. Longitudinal and transverse spin diffusion in3He-4He solutions in a strong magnetic field

    NASA Astrophysics Data System (ADS)

    Ager, J. H.; Child, A.; König, R.; Owers-Bradley, J. R.; Bowley, R. M.

    1995-06-01

    Using pulsed NMR techniques, we have measured spin diffusion in3He-3He solutions with3He concentrations of 0.05%, 0.1%, 0.46%, 1.0%, 3.8% and 6.4% in a magnetic field of 8.8 Tesla for a temperature range 11 mK⩽ T ⩽ 200 mK. We observe that the temperature dependence of the transverse spin diffusion coefficient D1 deviates from that expected for an unpolarized Fermi liquid in the degenerate region in the 1.0%, 3.8% and 6.4% solutions. Moreover, by measuring both longitudinal and transverse spin diffusion coefficients in the 6.4%-mixture, we have verified experimentally the difference between them, and provided direct evidence for a field-induced anisotropy in spin diffusion. The results from the 0.05% and 0.1% solutions show agreement with the theory of Jeon and Mullin; however, no deviation of D1 from that expected in an unpolarized mixture was observed because the3He is not in the degenerate regime for these very dilute systems for the temperatures we could achieve. The analysis of our measurements in terms of the Leggett-Rice equations also yields values for the spin rotation parameter μM0. Using our results along with previous measurements at various3He concentrations, we deduce a value for the s-wave quasiparticle scattering length of a=-0.88 ± 0.05 Å.

  7. Neutron Diffuse Reflectometry of Magnetic Thin Films with a 3He Analyzer

    NASA Astrophysics Data System (ADS)

    Chen, Wangchun; O'Donovan, Kevin; Borchers, Julie

    2005-03-01

    Polarized neutron reflectometry (PNR) is a powerful probe that characterizes the magnetization depth profile and magnetic domains in magnetic thin films. Although the conventionally used supermirrors are well-matched for specular PNR, they have limited angular acceptance and hence are impractical for complete characterization of the magnetic off-specular scattering where polarization analysis for diffusely reflected neutrons is required. Polarized ^3He gas, produced by optical pumping, can be used to polarize or analyze neutron beams because of the strong spin dependence of the neutron absorption cross section for ^3He. Here we report efficient polarization analysis of diffusely reflected neutrons in a reflectometry geometry using a polarized ^3He analyzer in conjunction with a position-sensitive detector (PSD). We obtained spin-resolved two-dimensional Qx-Qz reciprocal space maps for a patterned array of Co antidots in both the saturated and the demagnetized states. The preliminary results for a patterned amorphous bilayer, Gd40Fe60/ Tb55Fe45, measured with a ^3He analyzer and a PSD will also be discussed. Using the spin exchange optical pumping method we have achieved record high ^3He polarizations of 76% on the neutron beam line where we measured an initial analyzing efficiency of 0.97 and a neutron transmission for the desired spin state of 0.45.

  8. p +d →3He+γ reaction with pionless effective field theory

    NASA Astrophysics Data System (ADS)

    Nematollahi, H.; Bayegan, S.; Mahboubi, N.; Arani, M. Moeini

    2016-11-01

    We study the proton radiative capture by a deuteron with the pionless effective field theory [EFT(π / )] formalism. The calculation of the p d →3Heγ amplitude is considered for the incoming doublet and quartet channels leading to the formation of a 3He. The strong and Coulomb scattering amplitudes for the proton-deuteron (p d ) scattering are included in this study. In this calculation, the properly normalized 3He wave function has been used at each order. We evaluate both M 1 and E 1 transitions in the p d →3Heγ process up to NLO. We calculate the total cross section for the p d →3Heγ process based on the cluster-configuration space and compare it with the experimental data. The cross section results are presented for the incoming proton with the energy 0.5 ≤E ≤3 MeV where the lower and upper limits are chosen for the treatment of Coulomb effects perturbatively and the EFT(π / ) breakdown scale, respectively. No three-body force is needed to renormalize observables up to NLO other than those we have introduced in the p d scattering amplitudes.

  9. 3He spin filter based polarized neutron capability at the NIST Center for Neutron Research

    NASA Astrophysics Data System (ADS)

    Chen, W. C.; Gentile, T. R.; Erwin, R.; Watson, S.; Ye, Q.; Krycka, K. L.; Maranville, B. B.

    2014-07-01

    A 3He neutron spin filter (NSF) program for polarized neutron scattering was launched in 2006 as part of the National Institute of Standards and Technology (NIST) Center for Neutron Research (NCNR) Expansion Initiative. The goal of the project was to enhance the NCNR polarized neutron measurement capabilities. Benefitting from more than a decade's development of spin-exchange optical pumping (SEOP) at NIST, we planned to employ SEOP based 3He neutron spin filters for the polarized neutron scattering community. These 3He NSF devices were planned for use on different classes of polarized neutron instrumentation at the NCNR, including triple-axis spectrometers (TAS), small-angle neutron scattering instruments (SANS), reflectometers, and wide-angle polarization analysis. Among them, the BT-7 thermal TAS, NG-3 SANS, and MAGIK reflectometer have already been in the user program for routine polarized beam experiments. Wide-angle polarization analysis on Multi-Axis Crystal Spectrometer (MACS) has been developed for user experiments. We describe briefly the SEOP systems dedicated for polarized beam experiments and polarizing neutron development for each instrument class. We summarize the current status and polarized neutronic performance for each instrument. We present a 3He NSF hardware and software interface to allow for synchronization of 3He polarization inversion (neutron spin flipping) and free-induction decay (FID) nuclear magnetic resonance (NMR) measurements with neutron data collection.

  10. Results on Double-polarization Asymmetries in Quasielastic Scattering from Polarized 3He

    SciTech Connect

    Sulkosky, Vincent A.

    2016-03-01

    The 3He nucleus has become extremely important in the investigation of the neutron’s spin structure. When polarized, 3He acts as an effective polarized neutron target and hence facilitates our understanding of the neutron’s internal structure. However, to be used in this manner, our understanding of the internal structure of 3He is of extreme importance. As the precision of experiments has improved, the extraction of polarized neutron information from 3He leads to an ever larger share of the systematic uncertainty for these experiments. In these proceedings, I present a precise measurement of beam-target asymmetries in the and reactions. The former process is a uniquely sensitive probe of hadron dynamics in 3He and the structure of the underlying electromagnetic currents. The measurements have been performed around the quasi-elastic peak at Q2 = 0.25 (GeV/c)2 and 0.35 (GeV/c)2 for recoil momenta up to 270 MeV/c. The experimental apparatus, analysis and results were presented together with a comparison to state-of-the art Faddeev calculations.

  11. OBSERVATIONS OF EUV WAVES IN {sup 3}He-RICH SOLAR ENERGETIC PARTICLE EVENTS

    SciTech Connect

    Bucík, R.; Innes, D. E.; Guo, L.; Mason, G. M.; Wiedenbeck, M. E.

    2015-10-10

    Small {sup 3}He-rich solar energetic particle (SEP) events with their anomalous abundances, markedly different from the solar system, provide evidence for a unique acceleration mechanism that operates routinely near solar active regions. Although the events are sometimes accompanied by coronal mass ejections (CMEs), it is believed that mass and isotopic fractionation is produced directly in the flare sites on the Sun. We report on a large-scale extreme-ultraviolet (EUV) coronal wave observed in association with {sup 3}He-rich SEP events. In the two examples discussed, the observed waves were triggered by minor flares and appeared concurrently with EUV jets and type III radio bursts, but without CMEs. The energy spectra from one event are consistent with so-called class-1 (characterized by power laws) {sup 3}He-rich SEP events, while the other with class-2 (characterized by rounded {sup 3}He and Fe spectra), suggesting different acceleration mechanisms in the two. The observation of EUV waves suggests that large-scale disturbances, in addition to more commonly associated jets, may be responsible for the production of {sup 3}He-rich SEP events.

  12. SU-E-P-35: Real-Time Patient Transit Dose Verification of Volumetric Modulated Arc Radiotherapy by a 2D Ionization Chamber Array

    SciTech Connect

    Liu, X

    2015-06-15

    Purpose: To explore the real-time dose verification method in volumetric modulated arc radiotherapy (VMAT) with a 2D array ion chamber array. Methods: The 2D ion chamber array was fixed on the panel of electronic portal imaging device (EPID). Source-detector distance (SDD)was 140cm. 8mm RW3 solid water was added to the detector panel to achieve maximum readings.The patient plans for esophageal, prostate and liver cancers were selected to deliver on the cylindrical Cheese phantom 5 times in order to validate the reproducibility of doses. Real-time patient transit dose measurements were performed at each fraction. Dose distributions wereevaluated using gamma index criteria of 3mm DTA and 3% dose difference referred to the firsttime Result. Results: The gamma index pass rate in the Cheese phantom were about 98%; The gamma index pass rate for esophageal, liver and prostate cancer patient were about 92%,94%, and 92%, respectively; Gamma pass rate for all single fraction were more than 90%. Conclusion: The 2D array is capable of monitoring the real time transit doses during VMAT delivery. It is helpful to improve the treatment accuracy.

  13. Use of .sup.3 He.sup.30 + ICRF minority heating to simulate alpha particle heating

    DOEpatents

    Post, Jr., Douglass E.; Hwang, David Q.; Hovey, Jane

    1986-04-22

    Neutron activation due to high levels of neutron production in a first heated deuterium-tritium plasma is substantially reduced by using Ion Cyclotron Resonance Frequency (ICRF) heating of energetic .sup.3 He.sup.++ ions in a second deuterium-.sup.3 He.sup.++ plasma which exhibit an energy distribution and density similar to that of alpha particles in fusion reactor experiments to simulate fusion alpha particle heating in the first plasma. The majority of the fast .sup.3 He.sup.++ ions and their slowing down spectrum can be studied using either a modulated hydrogen beam source for producing excited states of He.sup.+ in combination with spectrometers or double charge exchange with a high energy neutral lithium beam and charged particle detectors at the plasma edge. The maintenance problems thus associated with neutron activation are substantially reduced permitting energetic alpha particle behavior to be studied in near term large fusion experiments.

  14. Heavy-baryon chiral perturbation theory approach to thermal neutron capture on {sup 3}He

    SciTech Connect

    Lazauskas, Rimantas; Park, Tae-Sun

    2011-03-15

    The cross section for radiative thermal neutron capture on {sup 3}He ({sup 3}He+n{yields}{sup 4}He+{gamma}; known as the hen reaction) is calculated based on heavy-baryon chiral perturbation theory. The relevant M1 operators are derived up to next-to-next-to-next-to-leading order (N{sup 3}LO). The initial and final nuclear wave functions are obtained from the rigorous Faddeev-Yakubovski equations for five sets of realistic nuclear interactions. Up to N{sup 3}LO, the M1 operators contain two low-energy constants, which appear as the coefficients of nonderivative two-nucleon contact terms. After determining these two constants using the experimental values of the magnetic moments of the triton and {sup 3}He, we carry out a parameter-free calculation of the hen cross section. The results are in good agreement with the data.

  15. Phase separation in dilute solutions of 3He in solid 4He

    NASA Astrophysics Data System (ADS)

    Huan, C.; Yin, L.; Xia, J. S.; Candela, D.; Cowan, B. P.; Sullivan, N. S.

    2017-03-01

    We report the results of studies of the phase separation of solid solutions of dilute concentrations of 3He in 4He. The temperatures and the kinetics of the phase separation were determined from NMR experiments for 3He concentrations 1.6 ×10-53He droplets shows a t1 /3 time dependence at long times consistent with Ostwald ripening.

  16. Rotational spectrum of the NH3-He van der Waals complex

    NASA Astrophysics Data System (ADS)

    Surin, L.; Schnell, M.

    2016-12-01

    The interaction between ammonia and helium has attracted considerable interest over many years, partly because of the observation of interstellar ammonia. The rate coefficients of NH3-He scattering are an important ingredient for numerical modeling of astrochemical environments. Another, though quite different application in which the NH3-He interaction can play an important role is the doping of helium clusters with NH3 molecules to perform high-resolution spectroscopy. Such experiments are directed on the detection of non-classical response of molecular rotation in helium clusters addressing fundamental questions related to the microscopic nature of superfluidity. High-resolution spectroscopy on the NH3-He complex is an important tool for increasing our understanding of intermolecular forces between NH3 and He.

  17. The Effect Of Neutron Attenuation On Power Deposition In Nuclear Pumped 3He-Lasers

    SciTech Connect

    Cetin, Fuesun

    2007-04-23

    Nuclear-pumped lasers (NPLs) are driven by the products of nuclear reactions and directly convert the nuclear energy to directed optical energy. Pumping gas lasers by nuclear reaction products has the advantage of depositing large energies per reaction. The need for high laser power output implies high operating pressure. In the case of volumetric excitation by 3He(n, p)3H reactions, however, operation at high pressure (more than a few atm) causes excessive neutron attenuation in the 3He gas. This fact adversely effects on energy deposition and, hence, laser output power and beam quality. Here, spatial and temporal variations of neutron flux inside a closed 3He -filled cylindrical laser tube have been numerically calculated for various tube radii and operating pressures by using a previously reported dynamic model for energy deposition. Calculations are made by using ITU TRIGA Mark II Reactor as the neutron source. The effects of neutron attenuation on power deposition are examined.

  18. Implications of new High 3He/4He Values from the Samoan Hotspot

    NASA Astrophysics Data System (ADS)

    Jackson, M. G.; Kurz, M. D.; Hart, S. R.; Workman, R.

    2005-12-01

    We report new olivine phenocryst helium measurements from Ofu Island, American Samoa; the 3He/4He ratios range from 19.5 to 33.7 times atmospheric (R/Ra), significantly expanding the observed range for Samoa. The highest 3He/4He ratio of 33.7 Ra was measured in olivines from an ankaramite dike. Relatively high helium concentrations (4.4*108 cc/g) in this sample, crushing and fusion measurements, coupled with sampling from a roadcut exposure, all ensure that the isotope ratio is not affected by in situ cosmogenic 3He. A second basaltic dike yielded a 3He/4He ratio of 29.6 Ra, and measurements on 9 other basalt samples from Ofu range from 19.5 to 26.4 Ra. Previous high 3He/4He measurements (~25 Ra) from the Samoan hotspot were also obtained from basaltic dikes, but were from Tutuila Island (Farley et al., 1992). The new high 3He/4He ratios from Samoa are similar in magnitude to the high ratios found at Iceland (~37 Ra) and Hawaii (~35 Ra). However, the Ofu basalts have 87Sr/86Sr > 0.7044, which is significantly more radiogenic than Iceland or Hawaii. The combined Sr-He isotopic data are broadly consistent with mixing between an enriched mantle source (EM2) and the putative common high 3He/4He component (FOZO, as best represented by Baffin Island Picrites, Stuart et al., 2003). Assuming that the overall isotopic variations are produced by mixing processes, we attempt to place constraints on the relative helium concentrations in the FOZO, EM2 and Depleted MORB mantle (DMM) endmembers. In addition to using the shape of the plausible mixing lines, we employ new estimates for the trace element concentrations in the DMM and Samoan EM2 sources (Workman et al., 2004; Workman and Hart, 2005) to get at relative helium concentrations in these reservoirs. We assume that high 3He/4He basalts from the mid-Atlantic ridge North of Iceland (Schilling et al., 1999, and others) are a mixture between DMM and FOZO. We further assume that the N. Iceland ridge-FOZO and Ofu-FOZO mixing

  19. Chiral effective field theory predictions for muon capture on deuteron and {3}He.

    PubMed

    Marcucci, L E; Kievsky, A; Rosati, S; Schiavilla, R; Viviani, M

    2012-02-03

    The muon-capture reactions {2}H(μ{-},ν{μ})nn and {3}He(μ{-},ν{μ}){3}H are studied with nuclear potentials and charge-changing weak currents, derived in chiral effective field theory. The low-energy constants (LECs) c{D} and c{E}, present in the three-nucleon potential and (c{D}) axial-vector current, are constrained to reproduce the A=3 binding energies and the triton Gamow-Teller matrix element. The muon-capture rates on deuteron and {3}He are predicted to be 399±3  sec{-1} and 1494±21  sec{-1}, respectively. The spread accounts for the cutoff sensitivity, as well as uncertainties in the LECs and electroweak radiative corrections. By comparing the calculated and precisely measured rates on {3}He, a value for the induced pseudoscalar form factor is obtained in good agreement with the chiral perturbation theory prediction.

  20. The Neutron and 3He Spin Structure Functions at Low Q^2

    SciTech Connect

    Vincent Sulkosky

    2009-08-01

    Experiment E97-110 was performed at the Thomas Jefferson National Accelerator Facility in Hall A to provide a precise measurement of the moments of the neutron and $^{3}$He spin structure functions. A longitudinally-polarized electron beam was scattered from a longitudinally or transversely polarized $^{3}$He target. The extended Gerasimov-Drell-Hearn integral and other moments of the neutron and $^{3}$He spin structure functions were extracted at very low momentum transfers (0.02 $< Q^{2} <$ 0.3 [GeV$/c$]$^{2}$). These data allow us to make a benchmark check of Chiral Perturbation Theory calculations in a region where they are expected to be valid. In these proceedings, the experimental details are discussed and preliminary results on the moments of the spin structure functions are presented.

  1. Observation of a new superfluid phase for 3He embedded in nematically ordered aerogel

    NASA Astrophysics Data System (ADS)

    Zhelev, N.; Reichl, M.; Abhilash, T. S.; Smith, E. N.; Nguyen, K. X.; Mueller, E. J.; Parpia, J. M.

    2016-09-01

    In bulk superfluid 3He at zero magnetic field, two phases emerge with the B-phase stable everywhere except at high pressures and temperatures, where the A-phase is favoured. Aerogels with nanostructure smaller than the superfluid coherence length are the only means to introduce disorder into the superfluid. Here we use a torsion pendulum to study 3He confined in an extremely anisotropic, nematically ordered aerogel consisting of ~10 nm-thick alumina strands, spaced by ~100 nm, and aligned parallel to the pendulum axis. Kinks in the development of the superfluid fraction (at various pressures) as the temperature is varied correspond to phase transitions. Two such transitions are seen in the superfluid state, and we identify the superfluid phase closest to Tc at low pressure as the polar state, a phase that is not seen in bulk 3He.

  2. Comparative study of nuclear effects in polarized electron scattering from 3 He

    DOE PAGES

    Ethier, J. J.; Melnitchouk, W.

    2013-11-01

    We present a detailed analysis of nuclear effects in inclusive electron scattering from polarized 3He nuclei for polarization asymmetries, structure functions and their moments, both in the nucleon resonance and deep-inelastic regions. We compare the results of calculations within the weak binding approximation at finite Q2 with the effective polarization ansatz often used in experimental data analyses, and explore the impact of Δ components in the nuclear wave function and nucleon off-shell corrections on extractions of the free neutron structure. Using the same framework we also make predictions for the Q2 dependence of quasielastic scattering from polarized 3He, data onmore » which can be used to constrain the spin-dependent nuclear smearing functions in 3He.« less

  3. A Short History of the Theory and Experimental Discovery of Superfluidity in 3He

    NASA Astrophysics Data System (ADS)

    Brinkman, W. F.

    I discuss the development of the theory and experiments on superfluid 3He. After the discovery of superfluidity in 3He by Osheroff, Richardson and Lee, Phil Anderson quickly recruited Doug Osheroff to come to Bell Labs and set up a dilution fridge to continue his experiments. One of the mysteries at that time was how the high-temperature A-phase, which has a gapless excitation spectrum, could be stabilized relative to the fully gapped, lower temperature B-phase. I explain how Phil Anderson and I developed the spin fluctuation theory of the A-phase of superfluid 3He which accounted for its stability, leading to the Anderson-Brinkman-Morel (ABM) theory of the superfluid A-phase...

  4. Magnetic field dependent transverse spin diffusion constant in 3He- 4He solutions

    NASA Astrophysics Data System (ADS)

    Owers-Bradley, J. R.; Child, A.; Bowley, R. M.

    1994-02-01

    The transverse spin diffusion constant of 3He- 4He solutions has been measured by pulsed nmr in magnetic fields of 2.18T and 8.8T for 3He concentrations of 0.5%, 1.0% and 3.8%. For the higher concentrations the diffusion constant at 8.8T is smaller than at 2.18T for the lowest temperatures used. The effect is largest for the 3.8% solution (a reduction by 1.7 at 15mK), but is too small to be measurable for the 0.5% solution. These results are compared to measurements of Candela et al. for pure 3He, and to the theory of Jeon and Mullin.

  5. Longitudinal assessment of treatment effects on pulmonary ventilation using 1H/3He MRI multivariate templates

    NASA Astrophysics Data System (ADS)

    Tustison, Nicholas J.; Contrella, Benjamin; Altes, Talissa A.; Avants, Brian B.; de Lange, Eduard E.; Mugler, John P.

    2013-03-01

    The utitlity of pulmonary functional imaging techniques, such as hyperpolarized 3He MRI, has encouraged their inclusion in research studies for longitudinal assessment of disease progression and the study of treatment effects. We present methodology for performing voxelwise statistical analysis of ventilation maps derived from hyper­ polarized 3He MRI which incorporates multivariate template construction using simultaneous acquisition of IH and 3He images. Additional processing steps include intensity normalization, bias correction, 4-D longitudinal segmentation, and generation of expected ventilation maps prior to voxelwise regression analysis. Analysis is demonstrated on a cohort of eight individuals with diagnosed cystic fibrosis (CF) undergoing treatment imaged five times every two weeks with a prescribed treatment schedule.

  6. A System for Open-Access 3He Human Lung Imaging at Very Low Field

    PubMed Central

    RUSET, I.C.; TSAI, L.L.; MAIR, R.W.; PATZ, S.; HROVAT, M.I.; ROSEN, M.S.; MURADIAN, I.; NG, J.; TOPULOS, G.P.; BUTLER, J.P.; WALSWORTH, R.L.; HERSMAN, F.W.

    2010-01-01

    We describe a prototype system built to allow open-access very-low-field MRI of human lungs using laser-polarized 3He gas. The system employs an open four-coil electromagnet with an operational B0 field of 4 mT, and planar gradient coils that generate gradient fields up to 0.18 G/cm in the x and y direction and 0.41 G/cm in the z direction. This system was used to obtain 1H and 3He phantom images and supine and upright 3He images of human lungs. We include discussion on challenges unique to imaging at 50 –200 kHz, including noise filtering and compensation for narrow-bandwidth coils. PMID:20354575

  7. Developing a long duration 3He fridge for the LSPE-SWIPE instrument

    NASA Astrophysics Data System (ADS)

    Coppi, Gabriele; de Bernardis, Paolo; May, Andrew J.; Masi, Silvia; McCulloch, Mark; Melhuish, Simon J.; Piccirillo, Lucio

    2016-07-01

    A 3He sorption cooler design for the Short-Wavelength Instrument for the Polarization Explorer (SWIPE) of the Large-Scale Polarization Explorer (LSPE) balloon-borne experiment is described. The aim of this experiment is the detection of the primordial B-mode polarisation component of the Cosmic Microwave Background. The SWIPE instrument will use Transition-Edge Sensors that are designed to work at temperature of almost 300 mK. Therefore, a 3He sorption cooler has been specifically designed that can reach this temperature with a heat load of up to 25 μW. The fridge is compact in order to be housed inside the SWIPE cryostat and operate vertically. It has been designed to have a cycle duration of at least 7 days. In order to meet these specifications, the fridge will be charged with 0.75 moles of 3He.

  8. Observation of a new superfluid phase for 3He embedded in nematically ordered aerogel

    PubMed Central

    Zhelev, N.; Reichl, M.; Abhilash, T. S.; Smith, E. N.; Nguyen, K. X.; Mueller, E. J.; Parpia, J. M.

    2016-01-01

    In bulk superfluid 3He at zero magnetic field, two phases emerge with the B-phase stable everywhere except at high pressures and temperatures, where the A-phase is favoured. Aerogels with nanostructure smaller than the superfluid coherence length are the only means to introduce disorder into the superfluid. Here we use a torsion pendulum to study 3He confined in an extremely anisotropic, nematically ordered aerogel consisting of ∼10 nm-thick alumina strands, spaced by ∼100 nm, and aligned parallel to the pendulum axis. Kinks in the development of the superfluid fraction (at various pressures) as the temperature is varied correspond to phase transitions. Two such transitions are seen in the superfluid state, and we identify the superfluid phase closest to Tc at low pressure as the polar state, a phase that is not seen in bulk 3He. PMID:27669660

  9. Characterizing a sewage plume using the 3H-3He dating technique

    USGS Publications Warehouse

    Shapiro, Stephanie Dunkle; LeBlanc, Denis; Schlosser, Peter; Ludin, Andrea

    1999-01-01

    An extensive 3H-3He study was performed to determine detailed characteristics of a regional flow system and a sewage plume over a distance of 4 km in a sand and gravel aquifer at Otis Air Base in Falmouth, Massachusetts. 3H-3He ages increase with depth in individual piezometer clusters and with distance along flowpaths. However, the age gradient with depth (Δt/Δz) is smaller in the plume than that in the regional waters, due to the intense recharge in the infiltration beds. The 1960s bomb peak of tritium in precipitation is archived longitudinally along a flowline through the main axis of the plume and vertically in individual piezometer clusters. On the eastern side of the sampling area, where water from Ashumet Pond forces plume water deeper into the flow system, 3H-3He ages are young at depth because the 3H-3He "clock" is reset due to outgassing of helium in the pond. A reconstruction of the tritium input functions for the regional and plume samples shows that there is no offset in the peak [3H]+[3Hetrit] concentrations for the plume and regional water, indicating that the water from supply wells for use on the base is young. The 3H-3He ages and detergent concentrations in individual wells are consistent with the beginning of use of detergents and the time period when their concentrations in sewage would have been greatest. Ages and hydraulic properties calculated using the 3H-3He data compare well with those from previous investigations and from particle-tracking simulations.

  10. JET (3He)-D scenarios relying on RF heating: survey of selected recent experiments

    SciTech Connect

    Van Eester, D.; Casati, A.; Crombe, K.; de la Luna, E.; Ericsson, G.; Felton, R.; Giroud, C.; Hjalmarsson, A.; Joffrin, E.; Kallne, J.; Kiptily, V.; Marinoni, A.; Santala, M.; Valisa, M.

    2009-03-01

    Recent JET experiments have been devoted to the study of (3He) D plasmas involving radio frequency (RF) heating. This paper starts by discussing the RF heating efficiency theoretically expected in such plasmas, covering both relevant aspects of wave and of particle dynamics. Then it gives a concise summary of the main conclusions drawn from recent experiments that were either focusing on studying RF heating physics aspects or that were adopting RF heating as a tool to study plasma behavior. Depending on the minority concentration chosen, different physical phenomena are observed. At very low concentration (X[3He] < 1%), energetic tails are formed which trigger MHD activity and result in loss of fast particles. Alfv n cascades were observed and gamma ray tomography indirectly shows the impact of sawtooth crashes on the fast particle orbits. Low concentration (X[3He] < 10%) favors minority heating while for X[3He] 10% electron mode conversion damping becomes dominant. Evidence for the Fuchs et al standing wave effect (Fuchs et al 1995 Phys. Plasmas 2 1637 47) on the absorption is presented. RF induced deuterium tails were observed in mode conversion experiments with large X[3He] (18%). As tentative modeling shows, the formation of these tails can be explained as a consequence of wave power absorption by neutral beam particles that efficiently interact with the waves well away from the cold D cyclotron resonance position as a result of their substantial Doppler shift. As both ion and electron RF power deposition profiles in (3He) D plasmas are fairly narrow giving rise to localized heat sources the RF heating method is an ideal tool for performing transport studies. Various of the experiments discussed here were done in plasmas with internal transport barriers (ITBs). ITBs are identified as regions with locally reduced diffusivity, where poloidal spinning up of the plasma is observed. The present know-how on the role of RF heating for impurity transport is also

  11. Boron-coated straws as a replacement for 3He-based neutron detectors

    NASA Astrophysics Data System (ADS)

    Lacy, Jeffrey L.; Athanasiades, Athanasios; Sun, Liang; Martin, Christopher S.; Lyons, Tom D.; Foss, Michael A.; Haygood, Hal B.

    2011-10-01

    US and international government efforts to equip major seaports with large area neutron detectors, aimed to intercept the smuggling of nuclear materials, have precipitated a critical shortage of 3He gas. It is estimated that the annual demand of 3He for US security applications alone is more than the worldwide supply. This is strongly limiting the prospects of neutron science, safeguards, and other applications that rely heavily on 3He-based detectors. Clearly, alternate neutron detection technologies that can support large sensitive areas, and have low gamma sensitivity and low cost must be developed. We propose a low-cost technology based on long copper tubes (straws), coated on the inside with a thin layer of 10B-enriched boron carbide ( 10B 4C). In addition to the high abundance of boron on Earth and low cost of 10B enrichment, the boron-coated straw (BCS) detector offers distinct advantages over conventional 3He-based detectors, and alternate technologies such as 10BF 3 tubes and 10B-coated rigid tubes. These include better distribution inside moderator assemblies, many-times faster electronic signals, no pressurization, improved gamma-ray rejection, no toxic or flammable gases, and ease of serviceability. We present the performance of BCS detectors dispersed in a solid plastic moderator to address the need for portal monitoring. The design adopts the outer dimensions of currently deployed 3He-based monitors, but takes advantage of the small BCS diameter to achieve a more uniform distribution of neutron converter throughout the moderating material. We show that approximately 63 BCS detectors, each 205 cm long, distributed inside the moderator, can match or exceed the detection efficiency of typical monitors fitted with a 5 cm diameter 3He tube, 187 cm long, pressurized to 3 atm.

  12. The Employment of a 3HE-Based Fast Neutron Spectrometer to Augment the DREO (Defence Research Establishment Ottawa) Radiation Measurement System,

    DTIC Science & Technology

    1985-10-01

    de contourner ces problies, le;1. CRDO 1 r~cenunent d~cid6 de muir son syst~me de spectroscopie neutronique d’une chambre d’lonlsatlon i 3He. Le pr...be considered, while the latter defines the active volumes in which these reactions may occur and in which the reaction products may propogate...8217L, .IL- OL a--! K7 %- V UNCLASSIFIED -4- " active volume" of the detector; any ionization track completely contained in this volume will result in the

  13. Electric breakdown and ionization detection in normal liquid and superfluid 4He for the SNA nEDM experiment

    NASA Astrophysics Data System (ADS)

    Karcz, Maciej

    A new experiment to search for the neutron electric dipole moment (nEDM) is under construction at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory. The SNS nEDM experiment is a national collaboration spanning over 20 universities and laboratories with more than 100 physicists and engineers contributing to the research and development. The search for a nEDM is a precision test of time reversal symmetry in particle physics, in the absence of a discovery, the SNS nEDM experiment seeks to improve the present limit on the nEDM value by two orders of magnitude. A non-zero value of the nEDM would help to explain the asym- metry between matter and anti-matter in the universe by providing an additional source of charge conjugation and parity symmetry violation, a necessary ingredient in the theory of baryogenesis in the early universe. The nEDM experiment will measure the Larmor precession frequency of neutrons by detecting scintillation from neutron capture by a dilute concentration of 3He inside a bath of superfluid 4He. Neutron capture by 3He is spin-dependent and the magnetic moments of the neutron and the 3He nucleus are comparable. A direct measurement of the precession frequency of polarized 3He and scintillation from neutron capture allows for the relative precession frequencies of 3He and the neutron to be determined. The experiment will then look for changes in the relative precession of 3He and neutrons under the influence of strong electric fields. 3He has negligible EDM and therefore any deviation due to an applied electric field would be from a nEDM. The nEDM experiment will need to apply strong electric fields inside superfluid (SF) 4He and it was necessary to investigate the ability of SF 4He to sustain electric fields. An experiment to study electric breakdown in superfluid 4He was constructed at the Indiana University Center for Exploration of Energy and Matter (CEEM). The experiment studied the electric breakdown behavior of liquid

  14. Two-photon exchange correction to 2 S -2 P splitting in muonic 3He ions

    NASA Astrophysics Data System (ADS)

    Carlson, Carl E.; Gorchtein, Mikhail; Vanderhaeghen, Marc

    2017-01-01

    We calculate the two-photon exchange correction to the Lamb shift in muonic 3He ions within the dispersion relations framework. Part of the effort entailed making analytic fits to the electron-3He quasielastic scattering data set, for purposes of doing the dispersion integrals. Our result is that the energy of the 2 S state is shifted downwards by two-photon exchange effects by 15.14(49) meV, in good accord with the result obtained from a potential model and effective field theory calculation.

  15. Bounds on New Spin Dependent Forces Between Neutrons Using a ^3He / ^129Xe Zeeman Maser

    NASA Astrophysics Data System (ADS)

    Glenday, Alex; Cramer, Claire; Phillips, David F.; Walsworth, Ronald L.

    2008-05-01

    Searches for new spin dependent macroscopic forces place bounds on physics beyond the Standard Model, such as Lorentz symmetry violation and existence of new particles like the axion. We report the first experimental limits on new spin dependent macroscopic forces between neutron spins. We measure the nuclear Zeeman frequencies of a ^3He / ^129Xe maser while we modulate the nuclear spin polarization of ^3He in a separate glass cell. We place limits on the coupling strength of dipole potentials mediated by axion-like particles (gpgp) at the 5.5x10-6 level for interactions at ranges longer than 40 cm.

  16. SEOP polarized 3He Neutron Spin Filters for the JCNS user program

    NASA Astrophysics Data System (ADS)

    Babcock, Earl; Salhi, Zahir; Theisselmann, Tobias; Starostin, Denis; Schmeissner, Johann; Feoktystov, Artem; Mattauch, Stefan; Pistel, Patrick; Radulescu, Aurel; Ioffe, Alexander

    2016-04-01

    Over the past several years the JCNS has been developing in-house applications for neutron polarization analysis (PA). These methods include PA for separation of incoherent from coherent scattering in soft matter studies (SANS), and online polarization for analysis for neutron reflectometry, SANS, GISANS and eventually spectroscopy. This paper will present an overview of the user activities at the JCNS at the MLZ and gives an overview of the polarization 3He methods and devices used. Additionally we will summarise current projects which will further support the user activities using polarised 3He spin filters.

  17. Resonance transition 795-nm Rubidium laser using 3He buffer gas

    SciTech Connect

    Wu, S S; Soules, T F; Page, R H; Mitchell, S C; Kanz, V K; Beach, R J

    2007-08-02

    We report the first demonstration of a 795-nm Rubidium resonance transition laser using a buffer gas consisting of pure {sup 3}He. This follows our recent demonstration of a hydrocarbon-free 795-nm Rubidium resonance laser which used naturally-occurring He as the buffer gas. Using He gas that is isotopically enriched with {sup 3}He yields enhanced mixing of the Rb fine-structure levels. This enables efficient lasing at reduced He buffer gas pressure, improving thermal management in high average power Rb lasers and enhancing the power scaling potential of such systems.

  18. Polarisation and compression of {sup 3}He for Magnetic Resonance Imaging purposes

    SciTech Connect

    Geurts, D. G.; Brand, J. F. J. van den; Bulten, H. J.; Poolman, H. R.; Ferro-Luzzi, M.; Nicolay, K.

    1998-01-20

    Magnetic Resonance Imaging is often used in medical science as a diagnostic tool for the human body. Conventional MRI uses the NMR signal from the protons of water molecules in tissue to image the interior of the patient's body. However, for certain areas such as the lungs and airways, the usage of a highly polarised gas yields better results. We are currently constructing an apparatus that uses polarised {sup 3}He gas to produce detailed images of those signal-deficient moyeties. We also plan to study possible uptake of polarised {sup 3}He gas by the circulatory system to image other organs.

  19. Observation of Half-Quantum Vortices in Topological Superfluid 3He

    NASA Astrophysics Data System (ADS)

    Autti, S.; Dmitriev, V. V.; Mäkinen, J. T.; Soldatov, A. A.; Volovik, G. E.; Yudin, A. N.; Zavjalov, V. V.; Eltsov, V. B.

    2016-12-01

    One of the most sought-after objects in topological quantum-matter systems is a vortex carrying half a quantum of circulation. They were originally predicted to exist in superfluid 3He -A but have never been resolved there. Here we report an observation of half-quantum vortices (HQVs) in the polar phase of superfluid 3He. The vortices are created with rotation or by the Kibble-Zurek mechanism and identified based on their nuclear magnetic resonance signature. This discovery provides a pathway for studies of unpaired Majorana modes bound to the HQV cores in the polar-distorted A phase.

  20. Two-body pion absorption on {sup 3}He at threshold

    SciTech Connect

    Lee, T.S.H.; Kiang, L.L.; Riska, D.O.

    1995-08-01

    We showed that a drastic reduction of the ratio of the rates of the reactions {sup 3}He({pi}{sup -},nn) and {sup 3}He({pi}{sup -},np) for stopped pions is obtained once the effect of the short-range two-nucleon components of the axial charge operator for nuclear systems is taken into account. In a calculation using realistic models of nucleon-nucleon interactions in the construction of these short-range components of the axial charge operator, the predicted ratios can be brought to within 10-20% of the empirical value. A paper describing our results was published.

  1. Pion single charge exchange scattering from 3He at 285, 428, and 525 MeV

    NASA Astrophysics Data System (ADS)

    Källne, J.; Altemus, R.; Gugelot, P. C.; McCarthy, J. S.; Minehart, R. C.; Orphanos, L.; Gram, P. A. M.; Höistad, B.; Morris, C. L.; Wadlinger, E. A.; Perdrisat, C. F.

    1982-02-01

    We have measured the cross section of 3He(π-,π0)3H at T=285, 428, and 525 MeV for angles in the range of 60°<~θ<~135° covering the momentum transfer range 0.5<~q<~1.0 GeV/c. Comparison is made with Glauber model calculations to discuss the sensitivity to nuclear structure and pion-nucleus interaction effects. NUCLEAR REACTIONS π-+3He-->3H+π0, T=285, 428, and 525 MeV, θπ0~70-140° measured σ(θt,Tπ). Analysis based on optical and Glauber model predictions.

  2. Observation of Half-Quantum Vortices in Topological Superfluid ^{3}He.

    PubMed

    Autti, S; Dmitriev, V V; Mäkinen, J T; Soldatov, A A; Volovik, G E; Yudin, A N; Zavjalov, V V; Eltsov, V B

    2016-12-16

    One of the most sought-after objects in topological quantum-matter systems is a vortex carrying half a quantum of circulation. They were originally predicted to exist in superfluid ^{3}He-A but have never been resolved there. Here we report an observation of half-quantum vortices (HQVs) in the polar phase of superfluid ^{3}He. The vortices are created with rotation or by the Kibble-Zurek mechanism and identified based on their nuclear magnetic resonance signature. This discovery provides a pathway for studies of unpaired Majorana modes bound to the HQV cores in the polar-distorted A phase.

  3. MeV ion loss during sup 3 He minority heating in TFTR

    SciTech Connect

    Zweben, S.J.; Hammett, G.; Boivin, R.; Phillips, C.; Wilson, R.

    1992-01-01

    The loss of MeV ions during {sup 3}He ICRH minority heating experiments has been measured using scintillator detectors near the wall of TFTR. The observed MeV ion losses to the bottom (90{degrees} poloidal) detector are generally consistent with the expected first-orbit loss of D-{sup 3}He alpha particle fusion products, with an inferred global reaction rate up to {approx}10{sup 16} reactions/sec. A qualitatively similar but unexpectedly large loss occurs 45{degrees} poloidally below the outer midplane. This additional loss might be due to ICRH tail ions or to ICRH wave-induced loss of previously confined fusion products.

  4. MeV ion loss during {sup 3}He minority heating in TFTR

    SciTech Connect

    Zweben, S.J.; Hammett, G.; Boivin, R.; Phillips, C.; Wilson, R.

    1992-01-01

    The loss of MeV ions during {sup 3}He ICRH minority heating experiments has been measured using scintillator detectors near the wall of TFTR. The observed MeV ion losses to the bottom (90{degrees} poloidal) detector are generally consistent with the expected first-orbit loss of D-{sup 3}He alpha particle fusion products, with an inferred global reaction rate up to {approx}10{sup 16} reactions/sec. A qualitatively similar but unexpectedly large loss occurs 45{degrees} poloidally below the outer midplane. This additional loss might be due to ICRH tail ions or to ICRH wave-induced loss of previously confined fusion products.

  5. Relativistic, QED, and nuclear mass effects in the magnetic shielding of 3He.

    PubMed

    Rudziński, Adam; Puchalski, Mariusz; Pachucki, Krzysztof

    2009-06-28

    The magnetic shielding sigma of (3)He is studied. The complete relativistic corrections of order O(alpha(2)), leading QED corrections of order O(alpha(3) ln alpha), and finite nuclear mass effects of order O(m/m(N)) are calculated with high numerical precision. The resulting theoretical predictions for sigma = 59.967 43(10)x10(-6) are the most accurate to date among all elements and support the use of (3)He as a NMR standard.

  6. Heat Transfer in 3He -4He Mixtures in Cylindrical Geometry

    NASA Astrophysics Data System (ADS)

    Nemchenko, K.; Rogova, S.; Vikhtinskaya, T.

    2017-02-01

    The paper presents the results of theoretical studies of the transport processes that take place in the newly proposed experiments on study of a vibrating quartz fork in superfluid 3He -4He mixtures. In addition to known mechanisms of energy loss from a vibrating quartz fork such as first sound radiation or interaction with thermal excitations, two more mechanisms specific for 3He -4He mixtures are proposed and studied in the paper. The relative contribution of these mechanisms: second sound and effective diffusion, is considered, and experimental conditions under which these mechanisms become effective are discussed.

  7. Exposure chamber

    DOEpatents

    Moss, Owen R.; Briant, James K.

    1983-01-01

    An exposure chamber includes an imperforate casing having a fluid inlet at the top and an outlet at the bottom. A single vertical series of imperforate trays is provided. Each tray is spaced on all sides from the chamber walls. Baffles adjacent some of the trays restrict and direct the flow to give partial flow back and forth across the chambers and downward flow past the lowermost pan adjacent a central plane of the chamber.

  8. The Gas Motion Due To Non-Uniform Heating By 3He(n,p)3H Reactions In The Nuclear-Pumped3He -Lasers

    SciTech Connect

    Cetin, Fuesun

    2007-04-23

    In the nuclear pumped-lasers, the passage of these energetic charged particles through gas results in a non-uniform volumetric energy deposition. This spatial non-uniformity induces a gas motion, which results in density and hence refractive index gradients that affects the laser's optical behaviour. The motion of 3He gas in a closed cavity is studied when it experiences transient and spatially non-uniform volumetric heating caused by the passage of 3He(n,p)3H reaction products. Gas motion is described by the radial velocity field of gas flow. Spatial and temporal variations of radial gas velocity are calculated for various tube parameters by using a dynamic energy deposition model. In the calculations, it is assumed that the laser tube is irradiated with neutrons from the pulse at a peak power of 1200 MW corresponding to a maximum thermal neutron flux of 8x1016 n / cm2sn in the central channel of ITU TRIGA Mark II Reactor. Results are examined.

  9. Degassing of 3H/3He, CFCs and SF6 by denitrification: measurements and two-phase transport simulations.

    PubMed

    Visser, Ate; Schaap, Joris D; Broers, Hans Peter; Bierkens, Marc F P

    2009-01-26

    The production of N2 gas by denitrification may lead to the appearance of a gas phase below the water table prohibiting the conservative transport of tracer gases required for groundwater dating. We used a two-phase flow and transport model (STOMP) to study the reliability of 3H/3He, CFCs and SF6 as groundwater age tracers under agricultural land where denitrification causes degassing. We were able to reproduce the amount of degassing (R2=69%), as well as the 3H (R2=79%) and 3He (R2=76%) concentrations observed in a 3H/3He data set using simple 2D models. We found that the TDG correction of the 3H/3He age overestimated the control 3He/3He age by 2.1 years, due to the accumulation of 3He in the gas phase. The total uncertainty of degassed 3H/3He ages of 6 years (+/-2 sigma) is due to the correction of degassed 3He using the TDG method, but also due to the travel time in the unsaturated zone and the diffusion of bomb peak 3He. CFCs appear to be subject to significant degradation in anoxic groundwater and SF6 is highly susceptible to degassing. We conclude that 3H/3He is the most reliable method to date degassed groundwater and that two-phase flow models such as STOMP are useful tools to assist in the interpretation of degassed groundwater age tracer data.

  10. Degassing of 3H/ 3He, CFCs and SF 6 by denitrification: Measurements and two-phase transport simulations

    NASA Astrophysics Data System (ADS)

    Visser, Ate; Schaap, Joris D.; Broers, Hans Peter; Bierkens, Marc F. P.

    2009-01-01

    The production of N 2 gas by denitrification may lead to the appearance of a gas phase below the water table prohibiting the conservative transport of tracer gases required for groundwater dating. We used a two-phase flow and transport model (STOMP) to study the reliability of 3H/ 3He, CFCs and SF 6 as groundwater age tracers under agricultural land where denitrification causes degassing. We were able to reproduce the amount of degassing ( R2 = 69%), as well as the 3H ( R2 = 79%) and 3He* ( R2 = 76%) concentrations observed in a 3H/ 3He data set using simple 2D models. We found that the TDG correction of the 3H/ 3He age overestimated the control 3He/ 3He age by 2.1 years, due to the accumulation of 3He* in the gas phase. The total uncertainty of degassed 3H/ 3He ages of 6 years (± 2 σ) is due to the correction of degassed 3He* using the TDG method, but also due to the travel time in the unsaturated zone and the diffusion of bomb peak 3He*. CFCs appear to be subject to significant degradation in anoxic groundwater and SF 6 is highly susceptible to degassing. We conclude that 3H/ 3He is the most reliable method to date degassed groundwater and that two-phase flow models such as STOMP are useful tools to assist in the interpretation of degassed groundwater age tracer data.

  11. Spectroscopic issues in optical polarization of 3He gas for Magnetic Resonance Imaging of human lungs

    NASA Astrophysics Data System (ADS)

    Dohnalik, T.; Głowacz, B.; Olejniczak, Z.; Pałasz, T.; Suchanek, M.; Wojna, A.

    2013-10-01

    The Magnetic Resonance Imaging (MRI) of human lungs for diagnostic purposes became possible by using nuclear spin hyperpolarized noble gases, such as 3He. One of the methods to polarize 3He is the Metastability Exchange Optical Pumping (MEOP), which up to now has been performed at low pressure of about 1 mbar and in low magnetic field below 0.1 T (standard conditions). The equilibrium nuclear polarization can reach up to 80%, but it is dramatically reduced during the subsequent gas compression to the atmospheric pressure that is necessary for the lungs examination. Further polarization losses occur during the transportation of the gas to the hospital scanner. It was shown recently that up to 50% polarization can be obtained at elevated pressure exceeding 20 mbar, by using magnetic field higher than 0.1 T (nonstandard conditions). Therefore, following the construction of the low-field MEOP polarizer located in the lab, a dedicated portable unit was developed, which uses the magnetic field of the 1.5 T MR medical scanner and works in the continuous-flow regime. The first in Poland MRI images of human lungs in vivo were obtained on the upgraded to 3He resonance frequency Siemens Sonata medical scanner. An evident improvement in the image quality was achieved when using the new technique. The paper shows how spectroscopic measurements of 3He carried out in various experimental conditions led both to useful practical results and to significant progress in understanding fundamental processes taking place during MEOP.

  12. Deep mixing of 3He: reconciling Big Bang and stellar nucleosynthesis.

    PubMed

    Eggleton, Peter P; Dearborn, David S P; Lattanzio, John C

    2006-12-08

    Low-mass stars, approximately 1 to 2 solar masses, near the Main Sequence are efficient at producing the helium isotope 3He, which they mix into the convective envelope on the giant branch and should distribute into the Galaxy by way of envelope loss. This process is so efficient that it is difficult to reconcile the low observed cosmic abundance of 3He with the predictions of both stellar and Big Bang nucleosynthesis. Here we find, by modeling a red giant with a fully three-dimensional hydrodynamic code and a full nucleosynthetic network, that mixing arises in the supposedly stable and radiative zone between the hydrogen-burning shell and the base of the convective envelope. This mixing is due to Rayleigh-Taylor instability within a zone just above the hydrogen-burning shell, where a nuclear reaction lowers the mean molecular weight slightly. Thus, we are able to remove the threat that 3He production in low-mass stars poses to the Big Bang nucleosynthesis of 3He.

  13. Direct Observation of a Majorana Quasiparticle Heat Capacity in 3He

    NASA Astrophysics Data System (ADS)

    Bunkov, Y. M.

    2014-04-01

    The Majorana fermion, which acts as its own antiparticle, was suggested by Majorana in 1937 (Nuovo Cimento 14:171). While no stable particle with Majorana properties has yet been observed, Majorana quasiparticles (QP) may exist at the boundaries of topological insulators. Here we report the preliminary results of direct observation of Majorana QPs by a precise measurements of superfluid 3He heat capacity. The bulk superfluid 3He heat capacity falls exponentially with cooling at the temperatures significantly below the energy gap. Owing to the zero energy gap mode the Majorana heat capacity falls in a power law. The Majorana heat capacity can be larger than bulk one at some temperature, which depends on surface to volume ratio of the experimental cell. Some times ago we developed the Dark matter particles detector (DMD) on a basis of superfluid 3He which is working at the frontier of extremely low temperatures (Winkelmann et al., Nucl. Instrum. Meth. A 559:384-386, 2006). Here we report the observation of zero gap mode of Majorana, follows from the new analyses of DMD heat capacity, published early. We have found a 10 % deviation from the bulk superfluid 3He heat capacity at the temperature of 135 μK. This deviation corresponds well to the theoretical value for Majorana heat capacity at such low temperature. (Note, there were no fitting parameters).

  14. Beam suppression of the DRAGON recoil separator for 3He(α,γ)7Be

    NASA Astrophysics Data System (ADS)

    Sjue, S. K. L.; Nara Singh, B. S.; Adsley, P.; Buchmann, L.; Carmona-Gallardo, M.; Davids, B.; Fallis, J.; Fulton, B. R.; Galinski, N.; Hager, U.; Hass, M.; Howell, D.; Hutcheon, D. A.; Laird, A. M.; Martin, L.; Ottewell, D.; Reeve, S.; Ruiz, C.; Ruprecht, G.; Triambak, S.

    2013-02-01

    Preliminary studies in preparation for an absolute cross-section measurement of the radiative capture reaction 3He(α,γ)7Be with the DRAGON recoil separator have demonstrated beam suppression >1014 at the 90% confidence level. A measurement of this cross section by observation of 7Be recoils at the focal plane of the separator should be virtually background free.

  15. Precise /sup 3/H-/sup 3/He mass difference for neutrino mass determination

    SciTech Connect

    Lippmaa, E.; Pikver, R.; Suurmaa, E.; Past, J.; Puskar, J.; Koppel, I.; Tammik, A.

    1985-01-28

    The precise /sup 3/H-/sup 3/He atomic mass difference has been measured by high-resolution (10/sup -8/) ion cyclotron resonance in a 4.7-T magnetic field. The result of 18 599 +- 2 eV favors a nonzero electron antineutrino mass.

  16. First viscosity of dilute3He-4He mixtures below 0.6 K

    NASA Astrophysics Data System (ADS)

    Um, Chung-In; Yoo, Sahng-Kyoon; Lee, Soo-Young; George, Thomas F.; Pandey, Lakshmi N.

    1994-01-01

    Starting with the Boltzmann transport equation, the first viscosity of dilute3He-4He mixtures for various3He concentrations x is evaluated up to around T ≅ 0.6 K by including the contribution from three-phonon processes (3PP) in the anomalous elementary excitation spectrum of liquid4He. Due to 3PP, the characteristic time τη for3He viscosity at high temperatures, i.e., T⩾2TF where TF is the3He Fermi temperature, is evaluated as 5 × 10-12/xT, which is smaller than the value estimated by Rosenbaum et al. This is interpolated with τη in the degenerate (quantum) region, T≪TF. The obtained viscosities are in better agreement with experimental results than those of Baym and Saam, whose theory does not include 3PP. However, at very low concentrations there exists a discrepancy between the present theory and experiments, so that an alternate treatment should be considered.

  17. Torsion Pendulum Experiments with Superfluid 3He in ``Nematically Ordered'' Aerogel

    NASA Astrophysics Data System (ADS)

    Zhelev, Nikolay; Smith, Eric; Sebastian, Abhilash; Parpia, Jeevak

    2014-03-01

    A new type of highly anisotropic alumina aerogel is used to induce directional disorder in superfluid 3He. The aerogel sample consists of a network of long strands that have a preferred orientation (nematic order). It is placed in the head of a double torsion pendulum with the anisotropy axis oriented along the axis of the pendulum. We observe the frequency shift of the symmetric torsion mode of the pendulum in order to determine the superfluid fraction of the embedded 3He. The superfluid transition temperature of the fluid in the aerogel is measured to be very close to that of bulk 3He. However, in contrast to the bulk phase diagram, the region of stability of the Equal Spin Pairing (ESP) superfluid phase is enhanced on cooling. In addition, unlike the case of 3He in isotropic silica aerogel, the ESP phase reappears on warming. We compare our measurements to the NMR data reported in and discuss the possible structure of the observed superfluid phases.

  18. Developments of In-Situ SEOP Polarized 3He Neutron Spin Filter in Japan

    NASA Astrophysics Data System (ADS)

    Kira, H.; Sakaguchi, Y.; Oku, T.; Suzuki, J.; Nakamura, M.; Arai, M.; Endoh, Y.; Chang, L. J.; Kakurai, K.; Arimoto, Y.; Ino, T.; Shimizu, H. M.; Kamiyama, T.; Ohoyama, K.; Hiraka, H.; Tsutsumi, K.; Yamada, K.

    2011-06-01

    We launched the polarized 3He neutron spin filters (NSF) project in order to provide neutron polarization for the pulsed neutron beams in Japan. We adopted the in-situ spin exchange optical pumping (SEOP) technique to polarize the nuclear spin of 3He atoms because it has some advantages for our applications. The overall system size is compact and it avoids the problem of the time decay of nuclear spin of 3He thus suppressing the costs of maintenance and providing other advantages [1, 2] with respect to data analysis and quality. In this paper, we performed pulsed neutron beam tests of our compact in-situ SEOP NSF system at the BL10 beamline in the Materials and Life Science Experimental Facility of the Japan Proton Accelerator Research Complex (J-PARC). The polarization of the 3He gas reached was 73 % and a pump-up time constant of 9.5 h was observed. This paper is a status report about the development of in-situ SEOP NSF system for the pulsed beam at J-PARC.

  19. Deep Mixing of 3He: Reconciling Big Bang and Stellar Nucleosynthesis

    SciTech Connect

    Eggleton, P P; Dearborn, D P; Lattanzio, J

    2006-07-26

    Low-mass stars, {approx} 1-2 solar masses, near the Main Sequence are efficient at producing {sup 3}He, which they mix into the convective envelope on the giant branch and should distribute into the Galaxy by way of envelope loss. This process is so efficient that it is difficult to reconcile the low observed cosmic abundance of {sup 3}He with the predictions of both stellar and Big Bang nucleosynthesis. In this paper we find, by modeling a red giant with a fully three-dimensional hydrodynamic code and a full nucleosynthetic network, that mixing arises in the supposedly stable and radiative zone between the hydrogen-burning shell and the base of the convective envelope. This mixing is due to Rayleigh-Taylor instability within a zone just above the hydrogen-burning shell, where a nuclear reaction lowers the mean molecular weight slightly. Thus we are able to remove the threat that {sup 3}He production in low-mass stars poses to the Big Bang nucleosynthesis of {sup 3}He.

  20. Testing on novel neutron detectors as alternative to 3He for security applications

    NASA Astrophysics Data System (ADS)

    Peerani, Paolo; Tomanin, Alice; Pozzi, Sara; Dolan, Jennifer; Miller, Eric; Flaska, Marek; Battaglieri, Marco; De Vita, Raffaella; Ficini, Luisa; Ottonello, Giacomo; Ricco, Giovanni; Dermody, Geraint; Giles, Calvin

    2012-12-01

    Detection of illicit trafficking of nuclear material relies on the detection of the radiation emitted. In the case of plutonium, one of the characteristic signatures derives from neutron emission. For this reason, neutron detectors cover an important role in detection systems. Most current neutron detection systems used for nuclear security are based on the 3He technology. Unfortunately, in the last few years the market of 3He has encountered huge problems in matching the supply and the demand. The need has grown significantly due to the increasing demand of instrumentation for security. This has caused an exponential increase of the price from one side and on the other side a serious strategic problem of resources. In order to guarantee the availability of detection systems for nuclear security, it is necessary to develop alternative detection systems based on technologies different from 3He. Many research projects have been devoted for the development of novel neutron detectors both by research organisations and by industries. Scientists from the PERLA laboratory of the Joint Research Centre (JRC) in Ispra, Italy, and their collaborators have tested several of these novel concepts in the last couple of years. This paper describes the detector systems tested at JRC and preliminary results on detectors that can be considered as promising alternatives to 3He.

  1. Surface Majorana fermions and bulk collective modes in superfluid 3He-B

    NASA Astrophysics Data System (ADS)

    Park, YeJe; Chung, Suk Bum; Maciejko, Joseph

    2015-02-01

    The theoretical study of topological superfluids and superconductors has so far been carried out largely as a translation of the theory of noninteracting topological insulators into the superfluid language, whereby one replaces electrons by Bogoliubov quasiparticles and single-particle band Hamiltonians by Bogoliubov-de Gennes Hamiltonians. Band insulators and superfluids are, however, fundamentally different: While the former exist in the absence of interparticle interactions, the latter are broken symmetry states that owe their very existence to such interactions. In particular, unlike the static energy gap of a band insulator, the gap in a superfluid is due to a dynamical order parameter that is subject to both thermal and quantum fluctuations. In this work, we explore the consequences of bulk quantum fluctuations of the order parameter in the B phase of superfluid 3He on the topologically protected Majorana surface states. Neglecting the high-energy amplitude modes, we find that one of the three spin-orbit Goldstone modes in 3He-B couples to the surface Majorana fermions. This coupling in turn induces an effective short-range two-body interaction between the Majorana fermions, with coupling constant inversely proportional to the strength of the nuclear dipole-dipole interaction in bulk 3He. A mean-field theory suggests that the surface Majorana fermions in 3He-B may be in the vicinity of a metastable gapped time-reversal-symmetry-breaking phase.

  2. Packed Powder as Superleak for Spin Pump Experiments in Superfluid 3He A1

    NASA Astrophysics Data System (ADS)

    Kamada, N.; Yamaguchi, A.; Motoyama, G.; Sumiyama, A.; Aoki, Y.; Okuda, Y.; Kojima, H.

    2014-04-01

    Experimental exploration of highly spin-polarized states of liquid 3He by applying external magnetic field is limited by the availability of static magnetic field. In the "ferromagnetic" superfluid A1 phase of liquid 3He there is an alternate method for boosting spin-polarization by the process of spin pumping without requiring such high magnetic field. The spin pumping in the A1 phase takes advantage of a superleak (SL) acting simultaneously as a filter for both entropy and spin. The spin pump technique that uses the SL-spin filter and a mechanical actuator enables us to directly boost polarization of 3He. The amount of enhancement of spin polarization has been limited so far. We are now developing a new type of SL filter made of packed aluminum oxide powder (referred as PAP-SL), in order to achieve greater enhancement of spin polarization. Several kinds of the PAP-SL filter were constructed by pressing aluminum oxide powders into a cylinder holder. The packed structures were carefully characterized by a flow-rate-measurement, X-ray tomography, and mercury intrusion porosimetry. The preliminary result shows that the PAP-SL works as SL filter for the superfluid 3He.

  3. A New Method for Precision Cold Neutron Polarimetry Using a 3He Spin Filter

    PubMed Central

    Wietfeldt, F. E.; Gentile, T. R.

    2005-01-01

    We present a new method for precision measurement of the capture flux polarization of a polychromatic (white), continuous cold neutron beam, polarized by a 3He spin filter. This method allows an in situ measurement and does not require knowledge of the neutron beam wavelength distribution. We show that a polarimetry precision of 0.1 % is possible. PMID:27308141

  4. Effect of 3He on the extinction of mass flux in solid helium

    NASA Astrophysics Data System (ADS)

    Vekhov, Ye.; Hallock, Robet

    2014-03-01

    The flux, F, carried by solid 4He , with nominal 300 ppb 3He concentration, χ, in the range 25.6 - 26.3 bar rises with falling temperature and at a temperature Td the flux decreases toward zero. The behavior of the flux above Td demonstrates the presence of a bosonic Luttinger liquid. We study F as a function of 3He concentration χ to explore the effect of 3He on Td. We find that the extinction of the flux is a sharp transition, typically complete within a few mK change in temperature. We find that Td is an increasing function of χ and we compare (Td , χ) with predictions for homogeneous phase separation. We conclude that phase separation plays an important role in the flux extinction. It is possible that the cores of edge dislocations carry the flux, and the flux is extinguished by the decoration by 3He of the cores or dislocation intersections. Supported by NSF DMR 12-05217.

  5. A New Method for Precision Cold Neutron Polarimetry Using a (3)He Spin Filter.

    PubMed

    Wietfeldt, F E; Gentile, T R

    2005-01-01

    We present a new method for precision measurement of the capture flux polarization of a polychromatic (white), continuous cold neutron beam, polarized by a (3)He spin filter. This method allows an in situ measurement and does not require knowledge of the neutron beam wavelength distribution. We show that a polarimetry precision of 0.1 % is possible.

  6. Spin correlations in quasi-elastic electron scattering from a (3)He internal target

    NASA Astrophysics Data System (ADS)

    Six, R. Edward, III

    The measurement of spin observables in the 3He-> (e->,e' ,d) and 3He-> (e->,e' ,p) reactions have been carried out at the Internal Target Facility of the Dutch National Institute for Nuclear and High Energy Physics (NIKHEF) in Amsterdam, The Netherlands, with a 720-MeV stored electron beam having a longitudinal polarization of 65% and an average current of 80 mA. This was the first measurement of the spin correlation parameters for the reaction 3He-> (e->,e' ,d) . The average target polarization was 45% with a thickness of 5 × 1014 atoms/cm2. The scattered electrons were detected in a large-acceptance, nonfocusing magnetic spectrometer located at a central angle of 40°. The knockout hadrons were detected in a non-magnetic detector located at a central angle of -56°. The central positions of the detectors correspond to quasi-elastic kinematics. The asymmetries A'x and A'x provide information on small components of the 3He ground-state wave function and on the isoscalar/isovector structure of the nuclear electromagnetic current. The results are compared with model calculations.

  7. Zeeman relaxation of cold atomic iron and nickel in collisions with {sup 3}He

    SciTech Connect

    Johnson, Cort; Newman, Bonna; Kleppner, Daniel; Greytak, Thomas J.; Brahms, Nathan; Doyle, John M.

    2010-06-15

    We have measured the ratio {gamma} of the diffusion cross section to the angular momentum reorientation cross section in the colliding Fe-{sup 3}He and Ni-{sup 3}He systems. Nickel (Ni) and iron (Fe) atoms are introduced via laser ablation into a cryogenically cooled experimental cell containing cold (<1 K) {sup 3}He buffer gas. Elastic collisions rapidly cool the translational temperature of the ablated atoms to the {sup 3}He temperature. {gamma} is extracted by measuring the decays of the atomic Zeeman sublevels. For our experimental conditions, thermal energy is comparable to the Zeeman splitting. As a result, thermal excitations between Zeeman sublevels significantly impact the observed decay. To determine {gamma} accurately, we introduce a model of Zeeman-state dynamics that includes thermal excitations. We find {gamma}{sub Ni-}{sup 3}{sub He}=5x10{sup 3} and {gamma}{sub Fe-}{sup 3}{sub He{<=}}3x10{sup 3} at 0.75 K in a 0.8-T magnetic field. These measurements are interpreted in the context of submerged shell suppression of spin relaxation, as studied previously in transition metals and rare-earth-metal atoms [C. I. Hancox, S. C. Doret, M. T. Hummon, R. V. Krems, and J. M. Doyle, Phys. Rev. Lett. 94, 013201 (2005); C. I. Hancox, S. C. Doret, M. T. Hummon, L. Luo, and J. M. Doyle, Nature (London) 431, 281 (2004); A. Buchachenko, G. Chaasiski, and M. Szczniak, Eur. Phys. J. D 45, 147 (2007)].

  8. Set-up of a high-resolution 300 mK atomic force microscope in an ultra-high vacuum compatible 3He/10 T cryostat

    NASA Astrophysics Data System (ADS)

    von Allwörden, H.; Ruschmeier, K.; Köhler, A.; Eelbo, T.; Schwarz, A.; Wiesendanger, R.

    2016-07-01

    The design of an atomic force microscope with an all-fiber interferometric detection scheme capable of atomic resolution at about 500 mK is presented. The microscope body is connected to a small pumped 3He reservoir with a base temperature of about 300 mK. The bakeable insert with the cooling stage can be moved from its measurement position inside the bore of a superconducting 10 T magnet into an ultra-high vacuum chamber, where the tip and sample can be exchanged in situ. Moreover, single atoms or molecules can be evaporated onto a cold substrate located inside the microscope. Two side chambers are equipped with standard surface preparation and surface analysis tools. The performance of the microscope at low temperatures is demonstrated by resolving single Co atoms on Mn/W(110) and by showing atomic resolution on NaCl(001).

  9. Set-up of a high-resolution 300 mK atomic force microscope in an ultra-high vacuum compatible (3)He/10 T cryostat.

    PubMed

    von Allwörden, H; Ruschmeier, K; Köhler, A; Eelbo, T; Schwarz, A; Wiesendanger, R

    2016-07-01

    The design of an atomic force microscope with an all-fiber interferometric detection scheme capable of atomic resolution at about 500 mK is presented. The microscope body is connected to a small pumped (3)He reservoir with a base temperature of about 300 mK. The bakeable insert with the cooling stage can be moved from its measurement position inside the bore of a superconducting 10 T magnet into an ultra-high vacuum chamber, where the tip and sample can be exchanged in situ. Moreover, single atoms or molecules can be evaporated onto a cold substrate located inside the microscope. Two side chambers are equipped with standard surface preparation and surface analysis tools. The performance of the microscope at low temperatures is demonstrated by resolving single Co atoms on Mn/W(110) and by showing atomic resolution on NaCl(001).

  10. Electron Bubbles in Superfluid ^3 He-A: Exploring the Quasiparticle-Ion Interaction

    NASA Astrophysics Data System (ADS)

    Shevtsov, Oleksii; Sauls, J. A.

    2016-11-01

    When an electron is forced into liquid ^3 He, it forms an "electron bubble", a heavy ion with radius, R˜eq 1.5 nm, and mass, M˜eq 100 m_3 , where m_3 is the mass of a ^3 He atom. These negative ions have proven to be powerful local probes of the physical properties of the host quantum fluid, especially the excitation spectra of the superfluid phases. We recently developed a theory for Bogoliubov quasiparticles scattering off electron bubbles embedded in a chiral superfluid that provides a detailed understanding of the spectrum of Weyl Fermions bound to the negative ion, as well as a theory for the forces on moving electron bubbles in superfluid ^3 He-A (Shevtsov and Sauls in Phys Rev B 94:064511, 2016). This theory is shown to provide quantitative agreement with measurements reported by the RIKEN group (Ikegami et al. in Science 341(6141):59, 2013) for the drag force and anomalous Hall effect of moving electron bubbles in superfluid ^3 He-A. In this report, we discuss the sensitivity of the forces on the moving ion to the effective interaction between normal-state quasiparticles and the ion. We consider models for the quasiparticle-ion (QP-ion) interaction, including the hard-sphere potential, constrained random-phase-shifts, and interactions with short-range repulsion and intermediate-range attraction. Our results show that the transverse force responsible for the anomalous Hall effect is particularly sensitive to the structure of the QP-ion potential and that strong short-range repulsion, captured by the hard-sphere potential, provides an accurate model for computing the forces acting on the moving electron bubble in superfluid 3 He-A.

  11. Comparison between impulsive 3He-rich events and energetic electron events

    NASA Astrophysics Data System (ADS)

    Wang, L.; Lin, R. P.; Krucker, S.; Mason, G. M.

    2005-05-01

    Impulsive solar energetic particle (SEP) events with large enrichments of 3He are associated with ~2-100 keV impulsive electrons. Electron observations with the energy range of ~3 eV - 500 keV by the WIND 3-D Plasma and Energetic Particle experiment (3DP) and ion measurements with the energy range of ~ 0.02 - 10 MeV/nucleon by the ACE Ultra-Low Energy Isotopic Spectrometer (ULEIS) provide the first possibility of an accurate timing comparison of between impulsive 3He-rich events and energetic electron events. We select eleven solar impulsive events with enhanced 3He/4He ratios (~0.1 - 1.5) and a clear velocity dispersion of both ion and electron events over a wide energy range. We remove the contaminations of higher energy electrons in Solid State Telescopes (SST) on WIND, determine the interplanetary path length from peak times of WIND electron data observed in situ, and obtain the electron injection profiles at the Sun from triangular fits to in situ observations. The onsets and peaks of the injection of 3He-rich ion events at the Sun are derived from those of ACE ion data observed in situ by taking into account the travel time along the path length comparable to electron events. The comparison study shows a systematic delay of the injection of 3He-rich ions events with respect to the injection of electron events. Nine of ten events have a fast (> 570 km/s) west CME observed by SOHO/LASCO with the onset of electron injection close to the origin of the CME, and with the onset of ion injection corresponding to a median height ~ 5 Rs of CME.

  12. 3HE RECOVERY FROM A TRITIUM-AGED LANA75 SAMPLE

    SciTech Connect

    Shanahan, K.

    2010-12-01

    {sup 3}He recovery is a topic of recent interest. One potential recovery source is from metal hydride materials once used to store tritium, as the decay product, {sup 3}He, is primarily trapped in the metal lattice, usually in bubbles, with such materials. In 2001, a Tritium Exposure Program (TEP) sample known as LANA75-SP1 was retired and the material was removed from the test cell and stored. Subsequently scoping temperature programmed desorption (TPD) experiments were conducted on that material to see what it might take to drive out He and residual H isotopes (the heel). Two experiments consisted of heating the sample in the presence of an excess of tin (the so-called Sn fusion experiment), and one was a simple TPD with no additives. Prior data on the so-called '21-month bed' material in the 1980's had produced {approx}21 cc of gas per gram of a LANA30 material (LaNi4.7Al0.3), with approximately 67% of that being {sup 3}He and the rest being D{sub 2} (Fig.3). However, the material had to be heated in excess of 850 C to obtain that level. Heating to less produced approximately half that amount of gas. The data also showed that {sup 3}He was released at different temperatures than the residual hydrogen isotopes. Unfortunately this implies full {sup 3}He recovery will be a difficult process. Therefore, it seemed advisable to attempt to extract as much information from the 3 scoping experiments from 2001-2 as possible.

  13. Exposure chamber

    DOEpatents

    Moss, Owen R.

    1980-01-01

    A chamber for exposing animals, plants, or materials to air containing gases or aerosols is so constructed that catch pans for animal excrement, for example, serve to aid the uniform distribution of air throughout the chamber instead of constituting obstacles as has been the case in prior animal exposure chambers. The chamber comprises the usual imperforate top, bottom and side walls. Within the chamber, cages and their associated pans are arranged in two columns. The pans are spaced horizontally from the walls of the chamber in all directions. Corresponding pans of the two columns are also spaced horizontally from each other. Preferably the pans of one column are also spaced vertically from corresponding pans of the other column. Air is introduced into the top of the chamber and withdrawn from the bottom. The general flow of air is therefore vertical. The effect of the horizontal pans is based on the fact that a gas flowing past the edge of a flat plate that is perpendicular to the flow forms a wave on the upstream side of the plate. Air flows downwardly between the chamber walls and the outer edges of the pan. It also flows downwardly between the inner edges of the pans of the two columns. It has been found that when the air carries aerosol particles, these particles are substantially uniformly distributed throughout the chamber.

  14. Observation of Intrinsic Magnus Force and Direct Detection of Chirality in Superfluid 3He-A

    NASA Astrophysics Data System (ADS)

    Ikegami, Hiroki; Tsutsumi, Yasumasa; Kono, Kimitoshi

    2015-04-01

    We report details of the observation of the intrinsic Magnus (IM) force acting on negative and positive ions trapped just below a free surface of the A phase of superfluid 3He (3He-A). From the transport measurements of the ions along the surface, we found that the IM force acts on both the negative and positive ions. We also demonstrate that the transport measurements could distinguish whether the surface is composed of a chiral monodomain or multiple chiral domains. For multiple chiral domains, the current of the ions was found to be irreproducible and unstable, which was reasonably explained by the formation of the chiral domain structure and the dynamics of the chiral domain walls. For chiral monodomains, the appearance ratio of chirality emerging upon cooling through the superfluid transition temperature was found to depend on the direction of the external magnetic field, which implies the existence of an unknown coupling between the chirality and the magnetic field.

  15. Spin echo small angle neutron scattering using a continuously pumped {sup 3}He neutron polarisation analyser

    SciTech Connect

    Parnell, S. R.; Li, K.; Yan, H.; Stonaha, P.; Li, F.; Wang, T.; Baxter, D. V.; Snow, W. M.; Washington, A. L.; Walsh, A.; Chen, W. C.; Parnell, A. J.; Fairclough, J. P. A.; Pynn, R.

    2015-02-15

    We present a new instrument for spin echo small angle neutron scattering (SESANS) developed at the Low Energy Neutron Source at Indiana University. A description of the various instrument components is given along with the performance of these components. At the heart of the instrument are a series of resistive coils to encode the neutron trajectory into the neutron polarisation. These are shown to work well over a broad range of neutron wavelengths. Neutron polarisation analysis is accomplished using a continuously operating neutron spin filter polarised by Rb spin-exchange optical pumping of {sup 3}He. We describe the performance of the analyser along with a study of the {sup 3}He polarisation stability and its implications for SESANS measurements. Scattering from silica Stöber particles is investigated and agrees with samples run on similar instruments.

  16. Effect of temperature on performance of {sup 3}He filled neutron proportional counters

    SciTech Connect

    Desai, Shraddha S.

    2014-04-24

    Neutron detectors used for cosmic neutron monitoring and various other applications are mounted in hostile environment. It is essential for detectors to sustain extreme climatic conditions, such as extreme temperature and humidity. Effort is made to evaluate the performance of detectors in extreme temperature in terms of pulse height distribution and avalanche formation. Neutron detectors filled with {sup 3}He incorporate an additive gas with quantity optimized for a particular application. Measurements are performed on neutron detectors filled with {sup 3}He and stopping gases Kr and CF{sub 4}. Detector performance for these fill gas combinations in terms of pulse height distribution is evaluated. Gas gain and Diethorn gas constants measured and analyzed for the microscopic effect on pulse formation. Results from these investigations are presented.

  17. [sup 3]He neutron detector performance in mixed neutron gamma environments

    SciTech Connect

    Johnson, N. H.; Beddingfield, D. H.

    2002-01-01

    A test program of the performance of 3He neutron proportional detectors with varying gas pressures, and their response to lligh level gamma-ray exposure in a mixed neutrodgamma environment, ha$ been performed Our intent was to identie the optimal gas pressure to reduce the gamma-ray sensitivity of these detectors. These detectors were manufxtured using materials to minimize their gamma response. Earlier work focused on 3He fill pressures of four atmospheres and above, whereas the present work focuses on a wider range of pressures. Tests have shown that reducing the .filling pressure will M e r increase the gamma-ray dose range in which the detectors can be operated.

  18. WORM ALGORITHM PATH INTEGRAL MONTE CARLO APPLIED TO THE 3He-4He II SANDWICH SYSTEM

    NASA Astrophysics Data System (ADS)

    Al-Oqali, Amer; Sakhel, Asaad R.; Ghassib, Humam B.; Sakhel, Roger R.

    2012-12-01

    We present a numerical investigation of the thermal and structural properties of the 3He-4He sandwich system adsorbed on a graphite substrate using the worm algorithm path integral Monte Carlo (WAPIMC) method [M. Boninsegni, N. Prokof'ev and B. Svistunov, Phys. Rev. E74, 036701 (2006)]. For this purpose, we have modified a previously written WAPIMC code originally adapted for 4He on graphite, by including the second 3He-component. To describe the fermions, a temperature-dependent statistical potential has been used. This has proven very effective. The WAPIMC calculations have been conducted in the millikelvin temperature regime. However, because of the heavy computations involved, only 30, 40 and 50 mK have been considered for the time being. The pair correlations, Matsubara Green's function, structure factor, and density profiles have been explored at these temperatures.

  19. Optical Pumping Spin Exchange {sup 3}He Gas Cells for Magnetic Resonance Imaging

    SciTech Connect

    Kim, W.; Stepanyan, S. S.; Kim, A.; Jung, Y.; Woo, S.; Yurov, M.; Jang, J.

    2009-08-04

    We present a device for spin-exchange optical pumping system to produce large quantities of polarized noble gases for Magnetic Resonance Imaging (MRI). A method and design of apparatus for pumping the polarization of noble gases is described. The method and apparatus enable production, storage and usage of hyperpolarized noble gases for different purposes, including Magnetic Resonance Imaging of human and animal subjects. Magnetic imaging agents breathed into lungs can be observed by the radio waves of the MRI scanner and report back physical and functional information about lung's health and desease. The technique known as spin exchange optical pumping is used. Nuclear magnetic resonance is implemented to measure the polarization of hyperpolarized gas. The cells prepared and sealed under high vacuum after handling Alkali metals into the cell and filling with the {sup 3}He-N{sub 2} mixture. The cells could be refilled. The {sup 3}He reaches around 50% polarization in 5-15 hours.

  20. High-3He plume origin and temporal-spatial evolution of the Siberian flood basalts

    USGS Publications Warehouse

    Basu, A.R.; Poreda, R.J.; Renne, P.R.; Teichmann, F.; Vasiliev, Y.R.; Sobolev, N.V.; Turrin, B.D.

    1995-01-01

    An olivine nephelinite from the lower part of a thick alkalic ultrabasic and mafic sequence of volcanic rocks of the northeastern part of the Siberian flood basalt province (SFBP) yielded a 40ArX39Ar plateau age of 253.3 ?? 2.6 million years, distinctly older than the main tholeiitic pulse of the SFBP at 250.0 million years. Olivine phenocrysts of this rock showed 3He/4He ratios up to 12.7 times the atmospheric ratio; these values suggest a lower mantle plume origin. The neodymium and strontium isotopes, rare earth element concentration patterns, and cerium/lead ratios of the associated rocks were also consistent with their derivation from a near-cnondritic, primitive plume. Geochemical data from the 250-million-year-old volcanic rocks higher up in the sequence indicate interaction of this high-3He SFBP plume with a suboceanic-type upper mantle beneath Siberia.

  1. Gadolinium Thin Foils in a Plasma Panel Sensor as an Alternative to 3He

    SciTech Connect

    Varner Jr, Robert L; Beene, James R; Friedman, Dr. Peter S.

    2010-01-01

    Gadolinium has long been investigated as a detector for neutrons. It has a thermal neutron capture cross-section that is unparalleled among stable elements, because of the isotopes $^{155,157}$Gd. As a replacement for $^3$He, gadolinium has a significant defect, it produces many gamma-rays with an energy sum of 8 MeV. It also produces conversion electrons, mostly 29 keV in energy. The key to replacing $^3$He with gadolinium is using a gamma-blind electron detector to detect the conversion electrons. We suggest that coupling a layer of gadolinium to a Plasma Panel Sensor (PPS) can provide highly efficient, nearly gamma-blind detection of the conversion. The PPS is a proposed detector under development as a dense array of avalanche counters based on plasma display technology. We will present simulations of the response of prototypes of this detector and considerations of the use of gadolinium in the PPS.

  2. Low Q^2 measurements of the neutron and 3He spin structure

    SciTech Connect

    Vincent Sulkosky

    2006-10-22

    Thomas Jefferson National Accelerator Facility experiment E97-110 was performed to provide a precise measurement of the extended Gerasimov-Drell-Hearn integral and of moments of the neutron and of the {sup 3}He spin structure functions. The momentum transfer range 0.02 < 0.3 (GeV)/c{sup 2} will allow us to test predictions of Chiral Perturbation Theory, and check the GDH sum rule by extrapolating the integral to the real photon point. The data have been taken in Hall A using a highly polarized electron beam and a polarized {sup 3}He target. The status of the data analysis is discussed, and preliminary results are shown.

  3. Compulsory Deep Mixing of 3He and CNO Isotopes on the First Giant Branch

    SciTech Connect

    Eggleton, P P; Dearborn, D P; Lattanzio, J

    2007-07-26

    We have found a deep-mixing process which occurs during First Giant Branch (FGB) evolution. It begins at the point in evolution where the surface convection zone (SCZ), having previously grown in size, starts to shrink, and it is driven by a local minimum that develops in the mean molecular weight as a result of the burning of {sup 3}He. This mixing can solve two important observational problems. One is why the interstellar medium (ISM) has not been considerably enriched in {sup 3}He since the Big Bang. The other is why products of nucleosynthesis such as {sup 13}C are progressively enriched on the upper FGB, when classical stellar modeling says that no further enrichment should take beyond the First Dredge-Up (FDU) episode, somewhat below the middle of the FGB.

  4. Neutron Polarization Measurements with a 3He Spin Filter for the NPDGamma Experiment

    NASA Astrophysics Data System (ADS)

    Musgrave, Matthew

    2012-10-01

    The Fundamental Neutron Physics Beamline (FNPB) at the Spallation Neutron Source (SNS) provides a pulsed beam of polarized cold neutrons for the NPDGamma experiment which intends to measure the parity violating asymmetry in the emitted gamma rays from the capture of polarized neutrons on protons in a para-hydrogen target. The neutrons are polarized by a multi-channel super mirror polarizer, and the polarization of each neutron pulse can be flipped with an RF spin rotator. The accuracy of the NPDGamma experiment and various commissioning experiments is dependent on the polarization of the neutron beam and the efficiency of the RF spin rotator. These parameters are measured with a polarized 3He spin filter at multiple points in the beam cross section and with multiple 3He polarizations. The measured neutron polarization is compared to a McStas model to validate our results and our beam averaging technique. The analysis methods, background effects, and results will be discussed.

  5. Cross section calculations of medical 103Pd radioisotope using α and 3He induced reactions

    NASA Astrophysics Data System (ADS)

    Demir, Bayram; Sarpün, Ismail Hakkı; Dogan, Yunus Emre

    2016-11-01

    One of the most popular radioisotopes used in the prostate brachytherapy is Palladium-103 (103Pd). The radioactive plaque is sewn onto the eye as to cover the intraocular tumor shadow with a 2-3 mm margin. These plaques are temporary and radiation is continuously delivered over 5 to 7 days. At the end of treatment, the plaque is removed from eye. In this study, production cross-section calculations of 103Pd radionuclide used in brachytherapy produced by 101Ru(α,2n), 100Ru(α,n), 102Ru(3He,2n) and 101Ru(3He,n) reactions have been investigated in the different incident energy range up to 35 MeV. Twocomponent Exciton model and Generalized Superfluid model of the TALYS 1.6 code used to perform calculations and calculation results were compared with experimental results reported in the literature.

  6. Apatite 4He/3He and (U-Th)/He evidence for an ancient Grand Canyon.

    PubMed

    Flowers, R M; Farley, K A

    2012-12-21

    The Grand Canyon is one of the most dramatic features on Earth, yet when and why it was carved have been controversial topics for more than 150 years. Here, we present apatite (4)He/(3)He thermochronometry data from the Grand Canyon basement that tightly constrain the near-surface cooling history associated with canyon incision. (4)He/(3)He spectra for eastern Grand Canyon apatites of differing He date, radiation damage, and U-Th zonation yield a self-consistent cooling history that substantially validates the He diffusion kinetic model applied here. Similar data for the western Grand Canyon provide evidence that it was excavated to within a few hundred meters of modern depths by ~70 million years ago (Ma), in contrast to the conventional model in which the entire canyon was carved since 5 to 6 Ma.

  7. Stability and dissipation of laminar vortex flow in superfluid 3He-B.

    PubMed

    Eltsov, V B; de Graaf, R; Heikkinen, P J; Hosio, J J; Hänninen, R; Krusius, M; L'vov, V S

    2010-09-17

    A central question in the dynamics of vortex lines in superfluids is dissipation on approaching the zero temperature limit T→0. From both NMR measurements and vortex filament calculations, we find that vortex flow remains laminar up to large Reynolds numbers Re{α}∼10(3) in a cylinder filled with 3He-B. This is different from viscous fluids and superfluid 4He, where the corresponding responses are turbulent. In 3He-B, laminar vortex flow is possible in the bulk volume even in the presence of sizable perturbations from axial symmetry to below 0.2Tc. The laminar flow displays no excess dissipation beyond mutual friction, which vanishes in the T→0 limit, in contrast with turbulent vortex motion where dissipation has been earlier measured to approach a large T-independent value at T≲0.2Tc.

  8. Separation of magnetization precession in 3He-B into two magnetic domains. Theory

    NASA Astrophysics Data System (ADS)

    Fomin, I. A.

    It is shown that even small deviations of the magnetic field from uniformity can substantially modify the magnetization precession in 3He-B. Specifically, a two-domain structure forms if the magnetic-field non-uniformity is linear. The magnetization makes an angle ˜ 104° with the field in one of the domains and is parallel to it in the other. These domains can explain the anomalously long persistence of the induction signal in 3He-B; moreover, the change in the induction-signal frequency with time discovered and investigated by Borovik-Romanov et al. [JETP Lett. 40, 1033 (1984)] is a consequence of the relaxation of the domain structure.

  9. Dynamics of {sup 3}He impurities in {sup 4}He films

    SciTech Connect

    Clements, B.E. |; Krotscheck, E. |; Saarela, M.

    1995-08-01

    Using a microscopic variational theory the authors calculate the binding energy of {sup 3}He impurities in films of {sup 4}He absorbed to a graphite substrate. Without adjustable parameters, they obtain excellent agreement with the experimental binding energies for the ground state of the {sup 3}He impurity. To calculate excited states, they then introduce a time-dependent variational wave function. In that way, the impurity acquires a hydrodynamic effective mass for its motion parallel to the surface due to hydrodynamic backflow. Excited states have a finite lifetime. When these effects are included, both the energy of the first excited state of the impurity, and the effective mass of the ground state, also agree well with experimental data.

  10. Orbital glass and spin glass states of 3He-A in aerogel

    NASA Astrophysics Data System (ADS)

    Dmitriev, V. V.; Krasnikhin, D. A.; Mulders, N.; Senin, A. A.; Volovik, G. E.; Yudin, A. N.

    2010-06-01

    Glass states of superfluid A-like phase of 3He in aerogel induced by random orientations of aerogel strands are investigated theoretically and experimentally. In anisotropic aerogel with stretching deformation two glass phases are observed. Both phases represent the anisotropic glass of the orbital ferromagnetic vector Ηthe orbital glass (OG). The phases differ by the spin structure: the spin nematic vector hat d can be either in the ordered spin nematic (SN) state or in the disordered spin-glass (SG) state. The first phase (OG-SN) is formed under conventional cooling from normal 3He. The second phase (OG-SG) is metastable, being obtained by cooling through the superfluid transition temperature, when large enough resonant continuous radio-frequency excitation is applied. NMR signature of different phases allows us to measure the parameter of the global anisotropy of the orbital glass induced by deformation.

  11. A Variable Path Length Cell for Transverse Acoustic Studies of Superfluid 3He

    NASA Astrophysics Data System (ADS)

    Collett, C. A.; Nguyen, M. D.; Li, J. I. A.; Zimmerman, A. M.; Halperin, W. P.; Davis, J. P.

    2015-03-01

    Transverse sound has recently emerged as an effective probe of the order parameter of superfluid 3He. Both the transverse acoustic impedance and attenuation have been shown to couple to surface bound states in 3He- B, which are predicted to be Majorana states in the specular scattering limit. In order to measure the attenuation at different path lengths to separate surface from bulk effects, as well as reduce the cavity size to the micron scale where transverse sound propagation should be measurable in the normal state, we have constructed a variable path length cell. Using a 4He-actuated diaphragm we demonstrate in-situ changes to the cavity length at dilution temperatures, and report our progress in deploying the cell at sub-mK temperatures. This research was supported by the National Science Foundation grant DMR-1103625.

  12. Thermal Transport by Ballistic Quasiparticles in Superfluid 3He-B in the Low Temperature Limit

    SciTech Connect

    Bradley, D. I.; Fisher, S. N.; Guenault, A. M.; Haley, R. P.; Martin, H.; Pickett, G. R.; Roberts, J. E.; Tsepelin, V.

    2006-09-07

    In the temperature range below 0.2Tc, the gas of thermal excitations from the superfluid 3He-B ground state is in the ultra-dilute ballistic regime. Here we discuss preliminary measurements of the transport properties of this quasiparticle gas in a cell of cylindrical geometry with dimensions much smaller than any mean free path. The vertical cylinder, constructed from epoxy-coated paper, has vibrating wire resonator (VWR) heaters and thermometers at the top and bottom, and a small aperture at the top which provides the only exit for quasiparticles. Using the thermometer VWRs, we measure the difference in quasiparticle density between the top and bottom of the tube when we excite the top or bottom VWR heater. This gives information about the transport of energy along the cylindrical 3He sample and hence about the scattering behaviour involved when a quasiparticle impinges on the cylinder wall.

  13. Strong-coupling effects in superfluid {sup 3}He in aerogel

    SciTech Connect

    Aoyama, Kazushi; Ikeda, Ryusuke

    2007-09-01

    Effects of impurity scatterings on the strong-coupling (SC) contribution, stabilizing the ABM (axial) pairing state, to the quartic term of the Ginzburg-Landau free energy of superfluid {sup 3}He are theoretically studied to examine recent observations suggestive of an anomalously small SC effect in superfluid {sup 3}He in aerogels. To study the SC corrections, two approaches are used. One is based on a perturbation in the short-range repulsive interaction, and the other is a phenomenological approach used previously for the bulk liquid by Sauls and Serene [Phys. Rev. B 24, 183 (1981)]. It is found that the impurity scattering favors the BW pairing state and shrinks the region of the ABM pairing state in the T-P phase diagram. In the phenomenological approach, the resulting shrinkage of the ABM region is especially substantial and, if assuming an anisotropy over a large scale in aerogel, leads to justifying the phase diagrams determined experimentally.

  14. Particle transport in 3 He-rich events: wave-particle interactions and particle anisotropy measurements

    NASA Astrophysics Data System (ADS)

    Tsurutani, B. T.; Zhang, L. D.; Mason, G. L.; Lakhina, G. S.; Hada, T.; Arballo, J. K.; Zwickl, R. D.

    2002-04-01

    Energetic particles and MHD waves are studied using simultaneous ISEE-3 data to investigate particle propagation and scattering between the source near the Sun and 1 AU. 3 He-rich events are of particular interest because they are typically low intensity "scatter-free" events. The largest solar proton events are of interest because they have been postulated to generate their own waves through beam instabilities. For 3 He-rich events, simultaneous interplanetary magnetic spectra are measured. The intensity of the interplanetary "fossil" turbulence through which the particles have traversed is found to be at the "quiet" to "intermediate" level of IMF activity. Pitch angle scattering rates and the corresponding particle mean free paths l

  15. Theory of (3He,(alpha)) surrogate reactions for deformed uranium nuclei

    SciTech Connect

    Thompson, I; Escher, J E

    2006-11-08

    We present the one-step theory of neutron-pickup transfer reactions with {sup 3}He projectiles on {sup 235}U and {sup 238}U. We find all the neutron eigenstates in a deformed potential, and use those in a given energy range for ({sup 3}He, {alpha}) DWBA pickup calculations to find the spin and parity distributions of the residual target nuclei. A simple smoothing convolution is used to take into account the spreading width of the single-neutron hole states into the more complicated compound nuclear states. We assume that the initial target is an even-even rotor, but can take into account spectator neutrons outside such a rotor by recombining their spin and parity at the end of the calculations.

  16. High-3He Plume Origin and Temporal-Spatial Evolution of the Siberian Flood Basalts.

    PubMed

    Basu, A R; Poreda, R J; Renne, P R; Teichmann, F; Vasiliev, Y R; Sobolev, N V; Turrin, B D

    1995-08-11

    An olivine nephelinite from the lower part of a thick alkalic ultrabasic and mafic sequence of volcanic rocks of the northeastern part of the Siberian flood basalt province (SFBP) yielded a (40)Ar/(39)Ar plateau age of 253.3 +/- 2.6 million years, distinctly older than the main tholeiitic pulse of the SFBP at 250.0 million years. Olivine phenocrysts of this rock showed (3)He/(4)He ratios up to 12.7 times the atmospheric ratio; these values suggest a lower mantle plume origin. The neodymium and strontium isotopes, rare earth element concentration patterns, and cerium/lead ratios of the associated rocks were also consistent with their derivation from a near-chondritic, primitive plume. Geochemical data from the 250-million-year-old volcanic rocks higher up in the sequence indicate interaction of this high-(3)He SFBP plume with a suboceanic-type upper mantle beneath Siberia.

  17. Surface Scattering Effect and the Stripe Order in Films of the Superfluid 3He B Phase

    NASA Astrophysics Data System (ADS)

    Aoyama, Kazushi

    2016-09-01

    Surface scattering effects in thin films of the superfluid 3He B phase have been theoretically investigated, with an emphasis on the stability of the stripe order with spontaneous broken translational symmetry in the film plane and quasiparticle excitations in this spatially inhomogeneous phase. Based on the Ginzburg-Landau theory in the weak coupling limit, we have shown that the stripe order, which was originally discussed for a film with two specular surfaces, can be stable in a film with one specular and one diffusive surfaces which should correspond to superfluid 3He on a substrate. It is also found by numerically solving the Eilenberger equation that due to the stripe structure, a midgap state distinct from the surface Andreev bound state emerges and its signature is reflected in the local density of states.

  18. Overview of the parity violation measurement of n+3 He --> p + t

    NASA Astrophysics Data System (ADS)

    Coppola, Christopher; n3He Collaboration

    2016-03-01

    The hadronic weak interaction remains the least well-understood of the weak interactions. There are multiple models with effective degrees of freedom characterizing its spin and isospin dependence. Measuring the strength of this interaction is difficult due to the much larger strong interaction between nucleons. However, parity violation in few-body reactions allows isolation of weak contributions on the order of 10-7 from the strong background. The size of parity violating asymmetry in the reaction n+3 He is expected to be of this order. The experiment has fininshed taking data from a 3He target in a polarized pulsed neutron beam at the Spallation Neutron Source at Oak Ridge National Laboratory. The expected precision of the asymmetry calculations is on the order of 10-8, and we are now in the analysis phase.

  19. On the optimisation of the use of 3He in radiation portal monitors

    NASA Astrophysics Data System (ADS)

    Tomanin, Alice; Peerani, Paolo; Janssens-Maenhout, Greet

    2013-02-01

    Radiation Portal Monitors (RPMs) are used to detect illicit trafficking of nuclear or other radioactive material concealed in vehicles, cargo containers or people at strategic check points, such as borders, seaports and airports. Most of them include neutron detectors for the interception of potential plutonium smuggling. The most common technology used for neutron detection in RPMs is based on 3He proportional counters. The recent severe shortage of this rare and expensive gas has created a problem of capacity for manufacturers to provide enough detectors to satisfy the market demand. In this paper we analyse the design of typical commercial RPMs and try to optimise the detector parameters in order either to maximise the efficiency using the same amount of 3He or minimise the amount of gas needed to reach the same detection performance: by reducing the volume or gas pressure in an optimised design.

  20. Nuclear structure corrections for μ4He+ and μ3He+ spectroscopy

    NASA Astrophysics Data System (ADS)

    Nevo Dinur, Nir; Ji, Chen; Hernandez, Oscar; Bacca, Sonia; Barnea, Nir

    2016-09-01

    The proton charge radius was recently determined from muonic hydrogen spectroscopy with tenfold improved precision but 7 . 9 σ disagreement with the accepted value, leading to the ``proton radius puzzle''. To further investigate, and to obtain precise radii, these measurements were repeated in μ4He+ and μ3He+. This may also shed light on the discrepancy between isotope-shift measurements of the 4He -3He radius difference. However, the precision of radii determined from the muonic experiments is limited by the uncertainties in the nuclear structure corrections. We present first ab-initio calculations of these corrections that reduced the uncertainties from 20 % to the few percent goal. TRIUMF receives federal funding via a contribution agreement with the National Research Council of Canada. This work was supported in parts by the Natural Sciences and Engineering Research Council (Grant Number SAPIN-2015-00031).

  1. Decoupling of first sound from second sound in dilute 3He-superfluid 4He mixtures

    NASA Astrophysics Data System (ADS)

    Riekki, T. S.; Manninen, M. S.; Tuoriniemi, J. T.

    2016-12-01

    Bulk superfluid helium supports two sound modes: first sound is an ordinary pressure wave, while second sound is a temperature wave, unique to superfluid systems. These sound modes do not usually exist independently, but rather variations in pressure are accompanied by variations in temperature, and vice versa. We studied the coupling between first and second sound in dilute 3He -superfluid 4He mixtures, between 1.6 and 2.2 K, at 3He concentrations ranging from 0% to 11%, under saturated vapor pressure, using a quartz tuning fork oscillator. Second sound coupled to first sound can create anomalies in the resonance response of the fork, which disappear only at very specific temperatures and concentrations, where two terms governing the coupling cancel each other, and second sound and first sound become decoupled.

  2. Magnon Condensation into a Q Ball in {sup 3}He-B

    SciTech Connect

    Bunkov, Yu. M.; Volovik, G. E.

    2007-06-29

    The theoretical prediction of Q balls in relativistic quantum fields is realized here experimentally in superfluid {sup 3}He-B. The condensed-matter analogs of relativistic Q balls are responsible for an extremely long-lived signal of magnetic induction observed in NMR at the lowest temperatures. This Q ball is another representative of a state with phase coherent precession of nuclear spins in {sup 3}He-B, similar to the well-known homogeneously precessing domain, which we interpret as Bose-Einstein condensation of spin waves--magnons. At large charge Q, the effect of self-localization is observed. In the language of relativistic quantum fields it is caused by interaction between the charged and neutral fields, where the neutral field provides the potential for the charged one. In the process of self-localization the charged field modifies locally the neutral field so that the potential well is formed in which the charge Q is condensed.

  3. In vivo lung morphometry with hyperpolarized 3He diffusion MRI: theoretical background.

    PubMed

    Sukstanskii, A L; Yablonskiy, D A

    2008-02-01

    MRI-based study of (3)He gas diffusion in lungs may provide important information on lung microstructure. Lung acinar airways can be described in terms of cylinders covered with alveolar sleeve [Haefeli-Bleuer, Weibel, Anat. Rec. 220 (1988) 401]. For relatively short diffusion times (on the order of a few ms) this geometry allows description of the (3)He diffusion attenuated MR signal in lungs in terms of two diffusion coefficients-longitudinal (D(L)) and transverse (D(T)) with respect to the individual acinar airway axis [Yablonskiy et al., PNAS 99 (2002) 3111]. In this paper, empirical relationships between D(L) and D(T) and the geometrical parameters of airways and alveoli are found by means of computer Monte Carlo simulations. The effects of non-Gaussian signal behavior (dependence of D(L) and D(T) on b-value) are also taken into account. The results obtained are quantitatively valid in the physiologically important range of airway parameters characteristic of healthy lungs and lungs with mild emphysema. In lungs with advanced emphysema, the results provide only "apparent" characteristics but still could potentially be used to evaluate emphysema progression. This creates a basis for in vivo lung morphometry-evaluation of the geometrical parameters of acinar airways from hyperpolarized (3)He diffusion MRI, despite the airways being too small to be resolved by direct imaging. These results also predict a rather substantial dependence of (3)He ADC on the experimentally-controllable diffusion time, Delta. If Delta is decreased from 3 ms to 1 ms, the ADC in normal human lungs may increase by almost 50%. This effect should be taken into account when comparing experimental data obtained with different pulse sequences.

  4. Mass superflux in solid helium: The role of 3He impurities

    NASA Astrophysics Data System (ADS)

    Vekhov, Ye.; Hallock, R. B.

    2015-09-01

    Below ˜630 mK, the 4He atom mass flux F , which passes through a cell filled with solid hcp 4He in the pressure range 25.6-26.4 bar, rises with falling temperature and, at a temperature Td, the flux drops sharply. The flux above Td has characteristics that are consistent with the presence of a bosonic Luttinger liquid. We study F as a function of 3He concentration, χ =0.17 -220 ppm , to explore the effect of 3He impurities on the mass flux. We find that the strong reduction of the flux is a sharp transition, typically complete within a few mK and a few hundred seconds. Modest concentration-dependent hysteresis is present. We find that Td is an increasing function of χ and the Td(χ ) dependence differs somewhat from the predictions for bulk phase separation for Tp s vs χ . We conclude that 3He plays an important role in the flux extinction. The dependence of F on the solid helium density is also studied. We find that F is sample dependent, but that the temperature dependence of F above Td is universal; data for all samples scale and collapse to a universal temperature dependence, independent of 3He concentration or sample history. The universal behavior extrapolates to zero flux in the general vicinity of Th≈630 mK . With increases in temperature, it is possible that a thermally activated process contributes to the degradation of the flux. The possibility of the role of disorder and the resulting phase slips as quantum defects on one-dimensional conducting pathways is discussed.

  5. Search for a bound trineutron with the 3He(π-pgr;+)nnn reaction

    NASA Astrophysics Data System (ADS)

    Gräter, J.; Amaudruz, P. A.; Bilger, R.; Camerini, P.; Clark, J.; Clement, H.; Friedman, E.; Felawka, L.; Filippov, S. N.; Friagiacomo, E.; Gavrilov, Y. K.; Gibson, E.; Grion, N.; Hofman, G. J.; Jamieson, B.; Karavicheva, T. L.; Kermanipresent Address: Sonigistix Corporation, Richmond, B. C., Canada V7A-5E3-->, M.; Mathie, E. L.; Meier, R.; Moloney, G.; Ottewell, D.; Pätzold, J.; Patarakin, O.; Raywood, K.; Rui, R.; Schepkin, M.; Sevior, M. E.; Smith, G. R.; Staudenmaier, H.; Tacik, R.; Tagliente, G.; Wagner, G. J.; Yeomans, M.

    1999-01-01

    A search for the production of a bound trineutron state has been performed using the reaction 3He(π-,π+)nnn at incident pion energies of 65, 75, and 120 MeV. No evidence for the existence of the 3n was found, and an upper limit for the production cross section of approximately 30 nb/sr (2σ confidence level) was obtained.

  6. Direct measurements of the magnetic field induced by optically polarized sup 3 He atoms

    SciTech Connect

    Gudoshnikov, S.A.; Snigirev, O.V. ); Kozlov, A.N.; Maslennikov, Y.V.; Serebrjakov, A.Y. )

    1991-03-01

    This paper reports on an alternative magnetic field induced by the standard cell of the optically pumped {sup 3}He magnetometer directly measured by the SQUID-based second-order gradiometer with signal-to-noise ratio higher than 6. The magnitude of the measured field equal to 5 {times} 10{sup {minus}13} T at the 5-cm distance from the cell axis and transverse relaxation time T{sub 2} equal to 7 minutes have been found.

  7. In vivo lung morphometry with hyperpolarized 3He diffusion MRI: Theoretical background

    NASA Astrophysics Data System (ADS)

    Sukstanskii, A. L.; Yablonskiy, D. A.

    2008-02-01

    MRI-based study of 3He gas diffusion in lungs may provide important information on lung microstructure. Lung acinar airways can be described in terms of cylinders covered with alveolar sleeve [Haefeli-Bleuer, Weibel, Anat. Rec. 220 (1988) 401]. For relatively short diffusion times (on the order of a few ms) this geometry allows description of the 3He diffusion attenuated MR signal in lungs in terms of two diffusion coefficients—longitudinal (D) and transverse (D) with respect to the individual acinar airway axis [Yablonskiy et al., PNAS 99 (2002) 3111]. In this paper, empirical relationships between D and D and the geometrical parameters of airways and alveoli are found by means of computer Monte Carlo simulations. The effects of non-Gaussian signal behavior (dependence of D and D on b-value) are also taken into account. The results obtained are quantitatively valid in the physiologically important range of airway parameters characteristic of healthy lungs and lungs with mild emphysema. In lungs with advanced emphysema, the results provide only "apparent" characteristics but still could potentially be used to evaluate emphysema progression. This creates a basis for in vivo lung morphometry—evaluation of the geometrical parameters of acinar airways from hyperpolarized 3He diffusion MRI, despite the airways being too small to be resolved by direct imaging. These results also predict a rather substantial dependence of 3He ADC on the experimentally-controllable diffusion time, Δ. If Δ is decreased from 3 ms to 1 ms, the ADC in normal human lungs may increase by almost 50%. This effect should be taken into account when comparing experimental data obtained with different pulse sequences.

  8. Superfluid 3-He: The Early Days as Seen by a Theorist

    NASA Astrophysics Data System (ADS)

    Leggett, Anthony

    2004-03-01

    After some background, I give some very personal reminiscences of the twelve-month period between July 1972 and July 1973, in which we came to a theoretical understanding of the puzzling experimental data on what we now know as superfluid 3-He. I particularly emphasize the concept of "spontaneously broken spin-orbit symmetry", which turned out to be important in understanding the NMR data.

  9. A Density Functional for Liquid 3He Based on the Aziz Potential

    NASA Astrophysics Data System (ADS)

    Barranco, M.; Hernández, E. S.; Mayol, R.; Navarro, J.; Pi, M.; Szybisz, L.

    2006-09-01

    We propose a new class of density functionals for liquid 3He based on the Aziz helium-helium interaction screened at short distances by the microscopically calculated two-body distribution function g(r). Our aim is to reduce to a minumum the unavoidable phenomenological ingredients inherent to any density functional approach. Results for the homogeneous liquid and droplets are presented and discussed.

  10. Elastic proton scattering on tritium below the n-{sup 3}He threshold

    SciTech Connect

    Lazauskas, Rimantas

    2009-05-15

    Elastic proton scattering on the {sup 3}H nucleus is studied between p-{sup 3}H and n-{sup 3}He thresholds, in the energy region where the first excited state of the {alpha} particle is embedded in the continuum. Faddeev-Yakubovski equations are solved in configuration space by fully considering effects from isospin breaking and rigorously treating the Coulomb interaction. Different realistic nuclear Hamiltonians are tested, elucidating open problems in the description of the nuclear interaction.

  11. A New 3He-Target Design for Compton Scattering Experiment

    NASA Astrophysics Data System (ADS)

    Mahalchick, S.; Gao, H.; Laskaris, G.; Weir, W.; Ye, Q.; Ye, Q. J.

    2011-10-01

    The neutron spin polarizabilities describe the stiffness of the neutron spin to external electric and magnetic fields. A double-polarized elastic Compton Scattering experiment will try to determine the neutron spin polarizabilities using a new polarized 3He target and the circularly polarized γ-beam of HI γS facility at the Duke Free Electron Laser Laboratory (DFELL). To polarize the 3He target, a newly constructed solenoid is being used which can provide a very uniform magnetic field around the target area and allows to place High Intensity Gamma Source NaI Detector Arrays (HINDA) closer to the target. The ideal target polarization is 40-60% and will be measured using the nuclear magnetic resonance (NMR) and electron paramagnetic resonance (EPR) techniques. A prototype of the polarized 3He target is being constructed in the Medium Energy Physics Group laboratories at Duke and is currently being tested. The experiment is expected to take place in 2013 after the DFELL upgrade. I will be presenting details of the construction process, including design specifications and data from the magnetic field mapping, as well as preliminary target polarization results. This work is supported by the US Department of Energy, under contract number DE-FG02-03ER41231, and by the National Science Foundation, grant number NSF-PHY-08-51813.

  12. Chiral effective field theory predictions for muon capture on deuteron and $^3$He

    SciTech Connect

    Laura E. Marcucci, A. Kievsky, S. Rosati, R. Schiavilla, M. Viviani

    2012-01-01

    The muon-capture reactions {sup 2}H({mu}{sup -}, {nu}{sub {mu}})nn and {sup 3}He({mu}{sup -},{nu}{sub {mu}}){sup 3}H are studied with nuclear strong-interaction potentials and charge-changing weak currents, derived in chiral effective field theory. The low-energy constants (LEC's) c{sub D} and c{sub E}, present in the three-nucleon potential and (c{sub D}) axial-vector current, are constrained to reproduce the A=3 binding energies and the triton Gamow-Teller matrix element. The vector weak current is related to the isovector component of the electromagnetic current via the conserved-vector-current constraint, and the two LEC's entering the contact terms in the latter are constrained to reproduce the A=3 magnetic moments. The muon capture rates on deuteron and {sup 3}He are predicted to be 399 {+-} 3 sec{sup -1} and 1494 {+-} 21 sec{sup -1}, respectively, where the spread accounts for the cutoff sensitivity as well as uncertainties in the LEC's and electroweak radiative corrections. By comparing the calculated and precisely measured rates on {sup 3}He, a value for the induced pseudoscalar form factor is obtained in good agreement with the chiral perturbation theory prediction.

  13. Hyperpolarized 3He functional magnetic resonance imaging of bronchoscopic airway bypass in chronic obstructive pulmonary disease

    PubMed Central

    Mathew, Lindsay; Kirby, Miranda; Farquhar, Donald; Licskai, Christopher; Santyr, Giles; Etemad-Rezai, Roya; Parraga, Grace; McCormack, David G

    2012-01-01

    A 73-year-old exsmoker with Global initiative for chronic Obstructive Lung Disease stage III chronic obstructive pulmonary disease underwent airway bypass (AB) as part of the Exhale Airway Stents for Emphysema (EASE) trial, and was the only EASE subject to undergo hyperpolarized 3He magnetic resonance imaging for evaluation of lung function pre- and post-AB. 3He magnetic resonance imaging was acquired twice previously (32 and eight months pre-AB) and twice post-AB (six and 12 months post-AB). Six months post-AB, his increase in forced vital capacity was <12% predicted, and he was classified as an AB nonresponder. However, post-AB, he also demonstrated improvements in quality of life scores, 6 min walk distance and improvements in 3He gas distribution in the regions of stent placement. Given the complex relationship between well-established pulmonary function and quality of life measurements, the present case provides evidence of the value-added information functional imaging may provide in chronic obstructive pulmonary disease interventional studies. PMID:22332133

  14. Hyperpolarized 3He functional magnetic resonance imaging of bronchoscopic airway bypass in chronic obstructive pulmonary disease.

    PubMed

    Mathew, Lindsay; Kirby, Miranda; Farquhar, Donald; Licskai, Christopher; Santyr, Giles; Etemad-Rezai, Roya; Parraga, Grace; McCormack, David G

    2012-01-01

    A 73-year-old exsmoker with Global initiative for chronic Obstructive Lung Disease stage III chronic obstructive pulmonary disease underwent airway bypass (AB) as part of the Exhale Airway Stents for Emphysema (EASE) trial, and was the only EASE subject to undergo hyperpolarized 3He magnetic resonance imaging for evaluation of lung function pre- and post-AB. 3He magnetic resonance imaging was acquired twice previously (32 and eight months pre-AB) and twice post-AB (six and 12 months post-AB). Six months post-AB, his increase in forced vital capacity was <12% predicted, and he was classified as an AB nonresponder. However, post-AB, he also demonstrated improvements in quality of life scores, 6 min walk distance and improvements in 3He gas distribution in the regions of stent placement. Given the complex relationship between well-established pulmonary function and quality of life measurements, the present case provides evidence of the value-added information functional imaging may provide in chronic obstructive pulmonary disease interventional studies.

  15. Improved neutron-gamma discrimination for a 3He neutron detector using subspace learning methods

    DOE PAGES

    Wang, C. L.; Funk, L. L.; Riedel, R. A.; ...

    2017-02-10

    3He gas based neutron linear-position-sensitive detectors (LPSDs) have been applied for many neutron scattering instruments. Traditional Pulse-Height Analysis (PHA) for Neutron-Gamma Discrimination (NGD) resulted in the neutron-gamma efficiency ratio on the orders of 105-106. The NGD ratios of 3He detectors need to be improved for even better scientific results from neutron scattering. Digital Signal Processing (DSP) analyses of waveforms were proposed for obtaining better NGD ratios, based on features extracted from rise-time, pulse amplitude, charge integration, a simplified Wiener filter, and the cross-correlation between individual and template waveforms of neutron and gamma events. Fisher linear discriminant analysis (FLDA) and threemore » multivariate analyses (MVAs) of the features were performed. The NGD ratios are improved by about 102-103 times compared with the traditional PHA method. Finally, our results indicate the NGD capabilities of 3He tube detectors can be significantly improved with subspace-learning based methods, which may result in a reduced data-collection time and better data quality for further data reduction.« less

  16. Large {sigma} Channel Low-Mass Enhancement in Exclusively Measured Double Pionic Fusion to 3He

    SciTech Connect

    Bashkanov, M.; Skorodko, T.; Clement, H.; Khakimova, O.; Kren, F.; Wagner, G. J.

    2006-07-11

    The pd {yields} 3He {pi}0{pi}0 and pd {yields} 3He {pi}+{pi}- reactions have been measured exclusively at CELSIUS using the WASA 4{pi} detector with pellet target system. For the double-pionic fusion to 3He data have been taken at Tp = 0.893 GeV, where the maximum of the socalled ABC effect is expected. A very large low-mass enhancement is observed in the {pi}0{pi}0 invariant mass spectrum M{pi}0{pi}0, whereas only a moderate low-mass enhancement is seen in M{pi}+{pi}- raising thus the question of isospin invariance in this region. With both channels summed up the data agree well to previous inclusive measurements regarding the low-mass enhancement. However, they do not exhibit the high-mass enhancement seen in the inclusive measurements and predicted by theoretical calculations based on a {delta}{delta} process, which produces a double-hump structure in the M{pi}{pi} spectra.

  17. The penetration of tritium and generation of 3He in the North Atlantic

    NASA Astrophysics Data System (ADS)

    Lott, D. E.; Jenkins, W. J.

    2007-12-01

    Based on large scale surveys such as GEOSECS, TTO, WOCE and CLIVAR, as well as smaller cruises, we now have observations that cover more nearly 35 years of the penetration of bomb-produced tritium and its daughter 3He in the North Atlantic Ocean. This data set offers us the opportunity to characterize the decade time-scale ventilation and circulation of the North Atlantic basin, and some insights into climate change and variability. Perhaps the most important aspect of this tracer pair is that the tritiugenic 3He is a unique transient tracer in that it highlights the return pathways of the ventilation process. This permits us to use it to constrain large scale fluxes of remineralized thermocline nutrients to the surface ocean, thus constraining basin scale new production. We describe the patterns of evolving tritium and 3He distributions within the subtropical North Atlantic and relate these to large scale circulation and ventilation. In addition, the evolving inventories of these tracers provide useful insights into the character of the meridional overturning circulation.

  18. Magnetism of Two-Dimensional Films of 3He on Highly Oriented Graphite

    NASA Astrophysics Data System (ADS)

    Bozler, H. M.; Zhang, Jinshan; Guo, Lei; Du, Yuliang; Gould, C. M.

    2006-09-01

    What is the effect of the structural length scale on the ordering of 3He films? NMR experiments on the magnetism of second layer 3He on Grafoil in the low field limit found ferromagnetic ordering for coverages over 20 atoms/nm2. Finite temperature phase transitions are prohibited in 2D when only Heisenberg interactions are present. However ordering of a two-dimensional magnetic film can be a result of a phase transition caused by weak anisotropy and/or dipolar interactions, or could be a less interesting manifestation of finite size effects. By replacing Grafoil with ZYX grade highly oriented graphite, we can study the magnetism of two-dimensional films with a substantially increased structural coherence length and test the importance of finite size effects. Our new experiments find a region of coverages where the second layer 3He films become ferromagnetic at temperatures above 1 mK, with no evidence for an increased suppression of the ordering due to increasing the coherence length. We show the results for the magnetism at a wide range of coverages as well as the effect of varying the magnetic field in the ferromagnetic cases. Our results support the interpretation in terms of a phase transition occurring at finite temperature.

  19. Gamma ray measurements during deuterium and /sup 3/He discharges on TFTR

    SciTech Connect

    Cecil, F.E.; Medley, S.S.

    1987-05-01

    Gamma ray count rates and energy spectra have been measured in TFTR deuterium plasmas during ohmic heating and during injection of deuterium neutral beams for total neutron source strengths up to 6 x 10/sup 15/ neutrons per second. The gamma ray measurements for the deuterium plasmas are in general agreement with predictions obtained using simplified transport models. The 16.6 MeV fusion gamma ray from the direct capture reaction D(/sup 3/He,..gamma..)/sup 5/Li was observed during deuterium neutral beam injection into /sup 3/He plasmas for beam powers up to 7 MW. The measured yield of the 16.6 MeV gamma ray is consistent with the predicted yield. The observation of this capture gamma ray establishes the spectroscopy of the fusion gamma rays from the D-/sup 3/He reactions as a viable diagnostic of total fusion reaction rates and benchmarks the modeling for extension of the technique to D-T plasmas. 21 refs., 12 figs.

  20. An accurate optical technique for measuring the nuclear polarisation of 3He gas

    NASA Astrophysics Data System (ADS)

    Talbot, C.; Batz, M.; Nacher, P.-J.; Tastevin, G.

    2011-06-01

    In the metastability exchange optical pumping cells of our on-site production unit and of our other experimental set-ups, we use a light absorption technique to measure the 3He nuclear polarisation. It involves weak probe beams at 1083 nm, that are either perpendicular or parallel to the magnetic field and cell axis, with suitable light polarisations. When metastability exchange collisions control the populations of the sublevels in the 23S state, absolute values of the 3He ground state nuclear polarisation are directly inferred from the ratio of the absorption rates measured for these probe beams. Our report focuses on the transverse detection scheme for which this ratio, measured at low magnetic field for σ and π light polarisations, hardly depends on gas pressure or the presence of an intense pump beam. This technique has been systematically tested both in pure 3He and isotopic mixtures and it is routinely used for accurate control of the optical pumping efficiency as well as for calibration of the NMR system.

  1. Differential cross sections for p+d-->γ+3He at intermediate energies

    NASA Astrophysics Data System (ADS)

    Briscoe, W. J.; Silverman, B. H.; Fitzgerald, D. H.; Nefkens, B. M. K.; Boudard, A.; Bruge, G.; Farvacque, L.; Glashausser, C.

    1985-12-01

    Differential cross sections have been measured for p+d-->γ+3He at Tp(lab)=300, 350, 400, 425, 450, 470, and 500 MeV for thetaγ(c.m.) near 60° and 90°. Measurements were also made for d+p-->γ+3He at Td=376 MeV for thetaγ(c.m.)=84°, 98°, and 113°, and at Td=600 MeV for thetaγ=96° and 105°. Our results are in agreement with those of the inverse reaction, γ+3He-->p+d of Sober et al., as is expected from time-reversal invariance. Our data agree with the latest results of Cameron et al. The older radiative capture measurements of Heusch et al. and the photodisintegration measurements made at other laboratories differ significantly from our results. Our data are compared with three theoretical models; the one proposed by Maximon and Prats comes closest to describing the data.

  2. Wire chamber

    DOEpatents

    Atac, Muzaffer

    1989-01-01

    A wire chamber or proportional counter device, such as Geiger-Mueller tube or drift chamber, improved with a gas mixture providing a stable drift velocity while eliminating wire aging caused by prior art gas mixtures. The new gas mixture is comprised of equal parts argon and ethane gas and having approximately 0.25% isopropyl alcohol vapor.

  3. A high rate proportional chamber

    SciTech Connect

    Henderson, R.; Fraszer, W.; Openshaw, R.; Sheffer, G.; Salomon, M.; Dew, S.; Marans, J.; Wilson, P.

    1987-02-01

    Gas mixtures with high specific ionization allow the use of small interelectrode distances while still maintaining full efficiency. With the short electron drift distances the timing resolution is also improved. The authors have built and operated two 25 cm/sup 2/ chambers with small interelectrode distances. Also single wire detector cells have been built to test gas mixture lifetimes. Various admixtures of CF/sub 4/, DME, Isobutane, Ethane and Argon have been tested. Possible applications of such chambers are as beam profile monitors, position tagging of rare events and front end chambers in spectrometers.

  4. Vertical groundwater flow estimated from the bomb pulse of 36Cl and tritiogenic 3He

    NASA Astrophysics Data System (ADS)

    Mahara, Y.; Ohta, T.

    2011-12-01

    The boring well was approximately excavated to 400 m depth from the ground surface on the tableland in the Central Shimokita Peninsula, Japan. Collecting pore-water, some fresh boring cores were sampled on the site during the excavation of borehole. Samples of groundwater were collected by using the sampling device with the water inflating packer system to protect various contaminations, after excavating the borehole. The atmospheric maximum concentration in bomb pulse in the northern hemisphere was reported to observe in 1955 for 36Cl and in 1963 for 3H, respectively. Since the half-life of 36Cl is much longer than 3H, the decay loss of 36Cl was negligible small for a short time until sampling groundwater in 2001 and 2003. On the other hand, the half-life of 3H is very short compared with that of 36Cl. Most of 3H was converted into the tritiogenic 3He in groundwater for the past 38 years after rainwater infiltrating toward the groundwater table. Profiles of dissolved 4He concentration, tritiogenic 3He and 36Cl/Cl ratio were observed in groundwater of the borehole. The total dissolved 4He concentration ranged from 5.8×10-8 at the ground surface to 7.5×10-8 ccSTP/g at the depth of 200 m below the ground surface and it was almost equilibrated with the atmospheric 4He in pore-water (Fig. 1). The bomb pulses of tritiogenic 3He and 36Cl were left from the depth of 101 m below the ground surface to the depth of 132 m, respectively (Figs. 2 and 3). There was a slight difference in the location between the bomb pulse of 36Cl and that of tritiogenic 3He. The downward flow velocity of groundwater were simply estimated to be 2.8 m/y from the marked position of bomb pulse in the profile of 36Cl/Cl ratio and to be 2.7 m/y from the position of the bomb pulse peak of tritiogenic 3He, separately. These two rough estimations were good agreed with each other. The estimation suggests that the vertical flow of groundwater on the tableland is approximated with the downward piston

  5. Calibration of cosmogenic 3He and 10Be production rates in the High Tropics

    NASA Astrophysics Data System (ADS)

    Blard, Pierre-Henri; Martin, Léo; Lavé, Jérôme; Charreau, Julien; Condom, Thomas; Lupker, Maarten; Braucher, Régis; Bourlès, Didier

    2014-05-01

    It is critical to refine both the accuracy and the precision of the in situ cosmogenic dating tool, especially for establishing reliable glacial chronologies that can be compared to other paleoclimatic records. Recent cross-calibrations of cosmogenic 3He in pyroxene and 10Be in quartz [1, 2] showed that, both at low (1300 m) and high elevation (4850 m), the 3He/10Be production ratio was probably ~40% higher than the value of ~23 initially defined in the 90's. This recent update is consistent with the last independent determinations of the sea level high latitude production rates of 10Be and 3He, that are about 4 and 125 at.g-1.yr-1, respectively [e.g. 3, 4]. However, major questions remain about these production rates at high elevation, notably because existing calibration sites for both 3He and 10Be are scarce above 2000 m. It is thus crucial to produce new high precision calibration data at high elevation. Here we report cosmogenic 10Be data from boulders sampled on a glacial fan located at 3800 m in the Central Altiplano (Bolivia), whose age is independently constrained by stratigraphic correlations and radiocarbon dating at ca. 16 ka. These data can be used to calibrate the production rate of 10Be at high elevation, in the Tropics. After scaling to sea level and high latitude, these data yield a sea level high latitude P10 ranging from 3.8 to 4.2 at.g-1.yr-1, depending on the used scaling scheme. These new calibration data are in good agreement with recent absolute and cross-calibration of 3He in pyroxenes and 10Be in quartz, from dacitic moraines located at 4850 m in the Southern Altiplano (22° S, Tropical Andes) [2,5]. The so-obtained 3He/10Be production ratio of 33.3±0.9 (1σ) combined with an absolute 3He production rate locally calibrated in the Central Altiplano, at 3800 m, indeed yielded a sea level high latitude P10 ranging from 3.7±0.2 to 4.1±0.2 at.g-1.yr-1, depending on the scaling scheme [2,5]. These values are also consistent with the 10Be

  6. Development of spatial-temporal ventilation heterogeneity and probability analysis tools for hyperpolarized 3He magnetic resonance imaging

    NASA Astrophysics Data System (ADS)

    Choy, S.; Ahmed, H.; Wheatley, A.; McCormack, D. G.; Parraga, G.

    2010-03-01

    We developed image analysis tools to evaluate spatial and temporal 3He magnetic resonance imaging (MRI) ventilation in asthma and cystic fibrosis. We also developed temporal ventilation probability maps to provide a way to describe and quantify ventilation heterogeneity over time, as a way to test respiratory exacerbations or treatment predictions and to provide a discrete probability measurement of 3He ventilation defect persistence.

  7. Apatite 4He/3He thermochronometry evidence for an ancient Grand Canyon, Colorado Plateau, USA

    NASA Astrophysics Data System (ADS)

    Flowers, R. M.; Farley, K. A.

    2012-12-01

    The very existence of Grand Canyon inspires questions about why canyons are carved, how drainage systems and landscapes evolve, and how these processes relate to the elevation gain of plateaus. Yet when and why Grand Canyon was carved have been extraordinarily controversial for more than 150 years. Over the last several decades, the dominant view for the origin of the canyon is one of rapid incision at 5-6 Ma, when detritus derived from the upstream reaches of the Colorado River system appeared in Grand Wash Trough at the Colorado River's western exit from the Colorado Plateau. The absence of such diagnostic deposits prior to 6 Ma has been used to argue that Grand Canyon was not yet excavated (e.g., Karlstrom et al., 2008). However, a variety of data hint at a more ancient age for part or all of the canyon, and it has been proposed that a smaller drainage basin in largely carbonate lithologies could explain the absence of pre-6 Ma Colorado River clastics in Grand Wash Trough even if a significant Grand Canyon were present. Most recently, apatite (U-Th)/He (AHe) thermochronometry data from western Grand Canyon were used to infer excavation of this area to within several hundred meters of its modern depth by ca. 70 Ma (Wernicke, 2011), an interpretation in direct conflict with the young canyon model. The unexpected implications of the initial Grand Canyon AHe work motivated the apatite 4He/3He and U-Th zonation study presented here. Apatite 4He/3He thermochronometry provides information about the spatial distribution of radiogenic 4He in an apatite crystal that can better constrain a sample's cooling history. A key premise of AHe and 4He/3He spectra interpretation is that the He kinetic model used is accurate. We first investigate whether differing 4He/3He spectra for apatites of variable AHe date, radiation damage, and U-Th zonation from eastern Grand Canyon yield mutually consistent thermal history results using the RDAAM kinetic model, which must be true if the

  8. Hybrid K-Rb Spin Exchange Optical Pumping Cells for the Polarization of ^3He

    NASA Astrophysics Data System (ADS)

    Couture, Alex; Daniels, Tim; Arnold, Charles; Clegg, Tom

    2006-11-01

    We are transitioning from polarizing ^3He using optical pumping cells charged with pure Rb to using a mixture of Rb and K, lean in Rb. The reason for this is the spin exchange efficiency between K and ^3He is an order of magnitude greater than that of Rb and ^3He. Also the spin exchange cross section between Rb and K is very large, which leads to a very fast rate of polarization transfer from Rb to K. Thus by optically pumping using a standard 795 nm Rb laser on a hybrid K-Rb cell, we can obtain significant improvements in spin-up time as well as improvements in overall polarization.[1] We produce hybrid pumping cells at TUNL using a filling station consisting of an oven and a turbo pumping station to bake out and pump away any impurities in the cells. The alkali metals are introduced into the pumping cells from a Y-shaped manifold with a separate retort for each alkali. We are able to determine the ratio of K to Rb in the vapor using white light absorption spectroscopy. Light from a halogen light bulb is incident upon the heated cell and enters a spectrometer beyond. We examine the relative sizes of the D1 and D2 absorption lines for the two alkali metals. We will have data comparing hybrid cells to pure Rb cells, GE-180 cells to Pyrex, and are working to obtain comparative performance data for spectrally unnarrowed and narrowed lasers. Our latest results will be reported. [1] E. Babcock, et al. (2003) Phys. Rev. Letter Vol. 91, Num.12, 123003

  9. Safety analysis of high pressure 3He-filled micro-channels for thermal neutron detection.

    SciTech Connect

    Ferko, Scott M.; Galambos, Paul C.; Derzon, Mark Steven; Renzi, Ronald F.

    2008-11-01

    This document is a safety analysis of a novel neutron detection technology developed by Sandia National Laboratories. This technology is comprised of devices with tiny channels containing high pressure {sup 3}He. These devices are further integrated into large scale neutron sensors. Modeling and preliminary device testing indicates that the time required to detect the presence of special nuclear materials may be reduced under optimal conditions by several orders of magnitude using this approach. Also, these devices make efficient use of our {sup 3}He supply by making individual devices more efficient and/or extending the our limited {sup 3}He supply. The safety of these high pressure devices has been a primary concern. We address these safety concerns for a flat panel configuration intended for thermal neutron detection. Ballistic impact tests using 3 g projectiles were performed on devices made from FR4, Silicon, and Parmax materials. In addition to impact testing, operational limits were determined by pressurizing the devices either to failure or until they unacceptably leaked. We found that (1) sympathetic or parasitic failure does not occur in pressurized FR4 devices (2) the Si devices exhibited benign brittle failure (sympathetic failure under pressure was not tested) and (3) the Parmax devices failed unacceptably. FR4 devices were filled to pressures up to 4000 + 100 psig, and the impacts were captured using a high speed camera. The brittle Si devices shattered, but were completely contained when wrapped in thin tape, while the ductile FR4 devices deformed only. Even at 4000 psi the energy density of the compressed gas appears to be insignificant compared to the impact caused by the incoming projectile. In conclusion, the current FR4 device design pressurized up to 4000 psi does not show evidence of sympathetic failure, and these devices are intrinsically safe.

  10. Linking Ventilation Heterogeneity Quantified via Hyperpolarized 3He MRI to Dynamic Lung Mechanics and Airway Hyperresponsiveness.

    PubMed

    Lui, Justin K; Parameswaran, Harikrishnan; Albert, Mitchell S; Lutchen, Kenneth R

    2015-01-01

    Advancements in hyperpolarized helium-3 MRI (HP 3He-MRI) have introduced the ability to render and quantify ventilation patterns throughout the anatomic regions of the lung. The goal of this study was to establish how ventilation heterogeneity relates to the dynamic changes in mechanical lung function and airway hyperresponsiveness in asthmatic subjects. In four healthy and nine mild-to-moderate asthmatic subjects, we measured dynamic lung resistance and lung elastance from 0.1 to 8 Hz via a broadband ventilation waveform technique. We quantified ventilation heterogeneity using a recently developed coefficient of variation method from HP 3He-MRI imaging. Dynamic lung mechanics and imaging were performed at baseline, post-challenge, and after a series of five deep inspirations. AHR was measured via the concentration of agonist that elicits a 20% decrease in the subject's forced expiratory volume in one second compared to baseline (PC20) dose. The ventilation coefficient of variation was correlated to low-frequency lung resistance (R = 0.647, P < 0.0001), the difference between high and low frequency lung resistance (R = 0.668, P < 0.0001), and low-frequency lung elastance (R = 0.547, P = 0.0003). In asthmatic subjects with PC20 values <25 mg/mL, the coefficient of variation at baseline exhibited a strong negative trend (R = -0.798, P = 0.02) to PC20 dose. Our findings were consistent with the notion of peripheral rather than central involvement of ventilation heterogeneity. Also, the degree of AHR appears to be dependent on the degree to which baseline airway constriction creates baseline ventilation heterogeneity. HP 3He-MRI imaging may be a powerful predictor of the degree of AHR and in tracking the efficacy of therapy.

  11. Anisotropic strong-coupling effects on superfluid 3He in aerogels: Conventional spin-fluctuation approach

    NASA Astrophysics Data System (ADS)

    Ikeda, Ryusuke

    2015-05-01

    Motivated by recent experiments on liquid 3He reporting emergence of novel superfluid phases in globally anisotropic aerogels, our previous theory on superfluid 3He in globally anisotropic aerogels is extended to incorporate the effects of anisotropy of the quasiparticle scattering cross section on the strong-coupling (SC) contributions to the Ginzburg-Landau (GL) free energy on the basis of the spin-fluctuation (paramagnon) approach to the SC contributions developed by Brinkman et al. [Phys. Rev. A 10, 2386 (1974), 10.1103/PhysRevA.10.2386]. In the globally isotropic case, impurity effects on the SC correction destabilize the A phase even at higher pressures of about 30 bar and make the B phase the only state in equilibrium, while SC contributions accompanied by a global stretched anisotropy to the GL quartic terms generally tend to broaden the stability region of the A phase compared with that of the B phase. In particular, in contrast to the cases in bulk and in the isotropic aerogel, the SC corrections to the GL quadratic terms are not negligible in the globally anisotropic case but may change the sign of the apparent anisotropy depending on the magnitude of the frequency cutoff of the normal paramagnon propagator. Based on this sign change of the apparent anisotropy, we discuss different strange observations on superfluid 3He in porous media such as the disappearance of the polar superfluid phase at higher pressures seen in nematically ordered aerogels and the absence of B and A phases with planar l ̂ vector in a stretched aerogel.

  12. /sup 3/He constant-volume gas thermometry: calculations for a temperature scale between 0. 8 and 25 K

    SciTech Connect

    Pavese, F.; Steur, P.P.M.

    1987-10-01

    A discussion is presented on the possibilities of a /sup 3/He gas thermometer for defining a temperature scale below 30 K, based on recent new measurements of the virial coefficient. The influence of all corrections of interest is given in comparison with /sup 4/He gas thermometry and with /sup 4/He and /sup 3/He vapor pressure thermometry. It is shown that a /sup 3/He gas thermometer can be operated down to temperatures < 1 K, with an estimated inaccuracy of less than +/- 0.5 mK, thereby obviating the explicit need of the /sup 3/He and /sup 4/He vapor pressure scales below 5K, and directly joining a possible scale based on the /sup 3/He melting curve.

  13. Constraining the Astrophysical S Factor of the 3He(α,γ)7Be Reaction

    NASA Astrophysics Data System (ADS)

    Carmona-Gallardo, M.; Rojas, A.; Nara Singh, B. S.; Akers, C.; Aviv, O.; Borge, M. J. G.; Christian, G.; Davids, B.; Fallis, J.; Fulton, B. R.; Hager, U.; Haquin, G.; Hass, M.; Hutcheon, D. A.; Nir-El, Y.; Ottewell, D.; Ruiz, C.; Sjue, S. K. L.; Tengblad, O.; Yaniv, R.; Yungreis, Z.

    The cross section of the 3He(α,γ)7Be reaction has been widely studied both from the theoretical and the experimental fronts due to its relevance to the standard solar model and to the Big Bang Nucleosynthesis calculations. We report here on cross section measurements in the energy region Ec.m. = 1-3 MeV using the direct recoil counting method in an attempt to resolve the discrepancies among the previous data sets and calculations in this energy region and thus to constrain the extrapolations of the S34(E) curve to astrophysical energies.

  14. /sup 3/He nuclear gyroscope. Final report, November 1980-July 1985

    SciTech Connect

    Shaw, G.L.

    1985-08-01

    The /sup 3/He nuclear gyroscope is a single-species cryogenic device that can be instrumented as a three-degree-of-freedom gyroscope. Sensitivities to dynamic terms can be molded, measured, and compensated by generation of cross-axis magnetic fields. The magnetic-field-generation scheme is the equivalent of putting the gyro on a stabilized platform but requires no moving parts. Such a gyroscope would be most useful integrated with other cryogenic instruments in a high-accuracy all-cryogenic inertial measurement unit.

  15. Contrasting Mechanical Anisotropies of the Superfluid {sup 3}He Phases in Aerogel

    SciTech Connect

    Bradley, D. I.; Fisher, S. N.; Guenault, A. M.; Haley, R. P.; O'Sullivan, S.; Pickett, G. R.; Roberts, J.; Tsepelin, V.; Mulders, N.

    2007-02-16

    There has been much recent interest in how impurity scattering may affect the phases of the p-wave superfluid {sup 3}He. Impurities may be added to the otherwise absolutely pure superfluid by immersing it in aerogel. Some predictions suggest that impurity scattering may destroy orientational order and force all of the superfluid phases to have an isotropic superfluid density. In contrast to this, we present experimental data showing that the response of the A-like phase to superfluid flow is highly anisotropic, revealing a texture that is easily modified by flow.

  16. Decay of Pure Quantum Turbulence in Superfluid {sup 3}He-B

    SciTech Connect

    Bradley, D.I.; Clubb, D.O.; Fisher, S.N.; Guenault, A.M.; Haley, R.P.; Matthews, C.J.; Pickett, G.R.; Tsepelin, V.; Zaki, K.

    2006-01-27

    We describe measurements of the decay of pure superfluid turbulence in superfluid {sup 3}He-B, in the low temperature regime where the normal fluid density is negligible. We follow the decay of the turbulence generated by a vibrating grid as detected by vibrating wire resonators. Despite the absence of any classical normal fluid dissipation processes, the decay is consistent with turbulence having the classical Kolmogorov energy spectrum and is remarkably similar to that measured in superfluid {sup 4}He at relatively high temperatures. Further, our results strongly suggest that the decay is governed by the superfluid circulation quantum rather than kinematic viscosity.

  17. Bogoliubov-normal interaction and calculation of thermal conductivity of superfluid A1-3He

    NASA Astrophysics Data System (ADS)

    Afzali, R.; Ebrahimian, N.

    2006-09-01

    The diffusive thermal conductivity tensor of the A 1-phase of superfluid 3He at low temperatures and melting pressure are calculated by s-p approximation, by using the Boltzmann equation approach. We obtain that the elements of the diffusive thermal conductivities, Kxx, Kyy, and Kzz, are proportional to T -1. Then we compare the results of this paper and our results of thermal conductivity based on Pfitzner procedure. Temperature dependence of both results is equal but numerical coefficients of them are little different. Also we show that Boguliubov-normal interaction is important in comparison to other interactions.

  18. Paramagnon and Size Effects for T c in Superfluid 3He Films

    NASA Astrophysics Data System (ADS)

    Furukawa, Hitoshi; Ohmi, Tetsuo

    1999-12-01

    The symmetry of Cooper pairs and transition temperature T c ofsuperfluid 3 He films thinner than coherence length withspecularly reflecting boundary are investigated. Using the paramagnon model for the pairing interaction, we show thesymmetry of pairs is likely p-wave and the gap at T c is theABM (or Planer) type. The quantum size effect yields the oscillatingbehavior of T c as a function of the film thickness. On the contrary to the result of Tesanovic and Valls, the transition temperature weobtained is higher than that of the bulk system.

  19. sup 18 O( sup 3 He, p ) sup 20 F reaction

    SciTech Connect

    Chowdhury, M.S.; Zaman, M.A.; Sen Gupta, H.M. )

    1992-12-01

    The {sup 18}O({sup 3}He,{ital p}){sup 20}F reaction has been studied at 18 MeV. Energy levels are measured up to {ital E}{sub {ital x}}{similar to}8.5 MeV and several new levels are observed. Angular distributions are measured for many of the levels and distorted wave Born approximation analyses are carried out. The {ital L} assignments are made and {ital J}{sup {pi}} limits are obtained.

  20. Coordinated Observations of Energetic Particles from 3He-rich Events by STEREO and ACE

    NASA Astrophysics Data System (ADS)

    Wiedenbeck, M. E.; Mason, G. M.; Cohen, C. M.; Nitta, N. V.; Gomez-Herrero, R.; Haggerty, D. K.

    2012-12-01

    The two STEREOs, together with ACE and other near-Earth spacecraft, have produced data sets that are well suited for investigating how 3He-rich energetic particles that are accelerated in reconnection events on the Sun get distributed in heliographic longitude. Our earlier study[1] of one such 3He-rich event (7 February 2010), which was detected at ACE and both STEREOs when they spanned 136o, showed that accelerated particles can be distributed over a wide range of longitudes even when they originate from a localized solar source. In addition, the particle fluences were found to decrease strongly with increasing distance from the longitude having the best magnetic connection to the source region. Based on data from the first four years of the STEREO mission, when solar activity was very low, we have used additional 3He-rich events detected by one or both of the STEREO/LET instruments and, in some cases also by ACE/ULEIS and/or SIS, to investigate the conditions under which the accelerated particles can gain access to a wide range of heliographic longitudes and to determine the longitudinal dependences of particle fluences in such events. During 2011 and 2012, when the level of solar activity has been significantly greater than in the preceding four years, unambiguous association of events detected at different spacecraft has been hampered by the possibility of chance coincidences between detections of particles from separate solar events as well as by the increased energetic particle background levels. We have investigated the possibility that event characteristics such as composition can be use to confirm that some events detected at widely spaced locations are associated with the same injection at the Sun. Such associations have the potential to extend the longitude range over which 3He-rich events can be studied and also to investigate the solar-cycle dependence of longitudinal spreading. We will report results from the statistical study of events that occurred

  1. Specific heat of /sup 3/He in the Fermi-liquid region

    SciTech Connect

    Mayberry, M.C.; Phillips, N.E.

    1983-03-01

    A CMN thermometer has been calibrated by nuclear-orientation thermometry at low temperatures and He vapor-pressure thermometry at high temperatures. The calibration agrees well with the NBS temperature scale between 100 and 200 mK. Specific-heat data on /sup 3/He in the Fermi-liquid region obtained with this thermometer are in good agreement with recent measurements at Bell Laboratories. It is argued that discrepancies with other data can be understood on the basis of errors in the temperature scales on which they are based.

  2. Two-Nucleon Momentum Distributions Measured in 3He(e,e'pp)n

    SciTech Connect

    R.A. Niyazov; L.B. Weinstein; et al

    2004-02-01

    We have measured the 3He(e,e'pp)n reaction at 2.2 GeV over a wide kinematic range. The kinetic energy distribution for ''fast'' nucleons (p > 250 MeV/c) peaks where two nucleons each have 20% or less, and the third nucleon has most of the transferred energy. These fast pp and pn pairs are back-to-back with little momentum along the three-momentum transfer, indicating that they are spectators. Experimental and theoretical evidence indicates that we have measured distorted two-nucleon momentum distributions by striking the third nucleon and detecting the spectator correlated pair.

  3. Precision spectroscopy of kaonic {sup 3}He X-rays at J-PARC

    SciTech Connect

    Sato, M.; Fujiwara, Y.; Hashimoto, T.; Hayano, R. S.; Ishikawa, T.; Shi, H.; Suzuki, T.; Tatsuno, H.; Bhang, H.; Choi, Seonho; Tanida, K.; Cargnelli, M.; Ishiwatari, T.; Marton, J.; Wuenschek, B.; Zmeskal, J.; Curceanu, C.; Guaraldo, C.; Okada, S.; Vidal, A. Romero

    2011-10-24

    We will measure the X-rays from kaonic {sup 3}He 3d {yields} 2p transition with a precision below 2 eV. It can provide crucial information on the kaon-nucleus strong interaction. The experiment (J-PARC E17) will be performed as Day-1, which is one of the first experiments in the J-PARC hadron facility in the year 2011. An overview and the present status of the J-PARC E17 experiment are described.

  4. Spin nutation in the quasi-isotropic A-like superfluid phase of {sup 3}He

    SciTech Connect

    Fomin, I. A.

    2006-06-15

    The order parameter of the quasi-isotropic A-like superfluid phase of {sup 3}He has been reduced to a simple form. The frequencies of the spatially homogeneous oscillations of the spin and the spin part of the order parameter of this phase have been obtained taking into account the anisotropy of its magnetic susceptibility. It has been shown that the anisotropy of susceptibility strongly affects the low-frequency oscillation mode, which is similar to the nutation of an asymmetric top. The possibility of observing this mode using the NMR method is discussed.

  5. Long term experience with the “industrial” 3He vapour-pressure thermometer

    NASA Astrophysics Data System (ADS)

    Benda, V.; Vafeiadis, T.

    2017-02-01

    On the basis of very good experience with a prototype of a 3He vapour-pressure thermometer installed in the magnet feed box (MFB – prototype of LHC magnet test bench), an upgraded version of this thermometer was developed with emphasis on the improvement of its long term stability, reliability and “series” production. The thermometer is working typically around 1.9 K. This article summarises the key points of the prototype design, its upgrade leading to the “industrial/series” realization, the long term experience and the calibration crosscheck of these thermometers after 15 years of operation.

  6. Effect of a Quenched Disorder on the Order Parameter of Superfluid 3He

    SciTech Connect

    Fomin, I. A.

    2006-09-07

    As a consequence of continuous degeneracy of the order parameter of the superfluid 3He quenched disorder in a form of aerogel gives rise both to a disruption of the orientational long-range order of the condensate and to a significant change of the order parameter itself. There exist a class of quasi-isotropic order parameters which are not sensitive to the disorienting effect of aerogel. While the BW order parameter belongs to this class the ABM does not. A possible candidate for the order parameter of the observed A-like phase is discussed.

  7. Equal-spin pairing state of superfluid {sup 3}He in aerogel

    SciTech Connect

    Aoyama, Kazushi; Ikeda, Ryusuke

    2005-07-01

    The equal-spin pairing state, the so-called A-like phase, of superfluid {sup 3}He in aerogels is studied theoretically in the Ginzburg-Landau region by examining thermodynamics, and the resulting equilibrium phase diagram is mapped out. We find that the ABM pairing state with presumably quasi-long-ranged superfluid order has a lower free energy than the planar and 'robust' states and is the best candidate of the A-like phase with a strange lowering of the polycritical point observed experimentally.

  8. Pairing states of superfluid {sup 3}He in uniaxially anisotropic aerogel

    SciTech Connect

    Aoyama, Kazushi; Ikeda, Ryusuke

    2006-02-01

    Stable pairing states of superfluid {sup 3}He in aerogel are examined in the case with a global uniaxial anisotropy which may be created by applying a uniaxial stress to the aerogel. Due to such a global anisotropy, the stability region of an Anderson-Brinkman-Morel (ABM) pairing state becomes wider. In a uniaxially stretched aerogel, the pure polar pairing state with a horizontal line node is predicted to occur, as a three-dimensional superfluid phase, over a measurable width just below the superfluid transition at T{sub c}(P). A possible relevance of the present results to the case with no global anisotropy is also discussed.

  9. Critical Velocity in the Presence of Surface Bound States in Superfluid 3He -B

    NASA Astrophysics Data System (ADS)

    Zheng, P.; Jiang, W. G.; Barquist, C. S.; Lee, Y.; Chan, H. B.

    2017-02-01

    A microelectromechanical oscillator with a gap of 1.25 μ m was immersed in superfluid 3He -B and cooled below 250 μ K at various pressures. Mechanical resonances of its shear motion were measured at various levels of driving force. The oscillator enters into a nonlinear regime above a certain threshold velocity. The damping increases rapidly in the nonlinear region and eventually prevents the velocity of the oscillator from increasing beyond the critical velocity which is much lower than the Landau critical velocity. We propose that this peculiar nonlinear behavior stems from the escape of quasiparticles from the surface bound states into the bulk fluid.

  10. Intrinsic pinning of vorticity by domain walls of l texture in superfluid 3He-A.

    PubMed

    Walmsley, P M; White, I J; Golov, A I

    2004-11-05

    We present the first observation of substantial persistent flow in superfluid 3He-A in thick simply connected slabs in a zero magnetic field, but only in l textures with domain walls. The flow is induced in a rotating cryostat using a torsional oscillator as a probe. The hysteretic dependences of the trapped vorticity on the maximal angular velocity of rotation are fairly universal for different densities of domain walls and slab thicknesses. A model of a critical state set by either the critical velocity for vortex nucleation or pinning strength explains all observations.

  11. {sup 3}He Spin-Dependent Cross Sections and Sum Rules

    SciTech Connect

    Slifer, K.; Auerbach, L.; Choi, Seonho; Incerti, S.; Lakuriqi, E.; Meziani, Z.-E.; Amarian, M.; Ketikyan, A.; Voskanian, H.; Averett, T.; Berthot, J.; Bertin, P.; DiSalvo, R.; Fonvieille, H.; Laveissiere, G.; Roblin, Y.

    2008-07-11

    We present a measurement of the spin-dependent cross sections for the {sup 3}He-vector (e-vector,e{sup '})X reaction in the quasielastic and resonance regions at a four-momentum transfer 0.1{<=}Q{sup 2}{<=}0.9 GeV{sup 2}. The spin-structure functions have been extracted and used to evaluate the nuclear Burkhardt-Cottingham and extended Gerasimov-Drell-Hearn sum rules for the first time. The data are also compared to an impulse approximation calculation and an exact three-body Faddeev calculation in the quasielastic region.

  12. Oceanic lavas sampling the high 3He/4He mantle reservoir: Primitive, depleted, or re-enriched?

    NASA Astrophysics Data System (ADS)

    Garapic, G.; Mallik, A.; Dasgupta, R.; Jackson, M. G.

    2014-12-01

    Helium isotopes are used as a tracer for primitive reservoirs that have persisted in the Earth's mantle. Basalts erupted at several intraplate oceanic islands, including Hawaii, Iceland, Galapagos and Samoa, have hosted the highest 3He/4He ratios (> 30 Ra, where Ra is atmospheric 3He/4He ratio) globally that are far in excess of the 3He/4He typical of the upper mantle sampled at mid-ocean ridges (8 Ra). These lavas have been suggested to be melts of a primitive, or possibly slightly depleted, mantle reservoir, i.e., either fertile or a depleted peridotite. We report evidence for geochemical enrichment in the high 3He/4He mantle sampled by lavas with the highest 3He/4He from Hawaii, Samoa and possibly Galapagos. The titanium concentrations in high 3He/4He lavas from Samoa are too high to be explained by melts of a mantle peridotite, even at infinitesimally small degrees of melting, and the elevated Ti corresponds to elevated Pb-isotopic ratios. The highest 3He/4He lavas from Loihi, Hawaii have Ti concentrations that are too high to be melts of primitive mantle peridotite at the degrees of melt extraction proposed for those ocean islands. Thus, Ti-rich material must have been added to the high 3He/4He mantle reservoir, and this material is likely to be recycled mafic crust similar to MORB-like eclogite, which is consistent with the elevated Pb-isotopic ratios. We show that fractionation corrected, major element compositions of high 3He/4He alkalic lavas can be satisfactorily modeled by melting and melt-rock interaction scenario in a fertile peridotite-MORB-eclogite hybrid system. Primitive peridotitic and recycled eclogitic reservoirs are suggested to be intimately associated in the deepest mantle and far from being primitive, the high 3He/4He lavas may sample a mantle source that hosts a component of recycled oceanic crust.

  13. Development of a 3He nuclear spin flip system on an in-situ SEOP 3He spin filter and demonstration for a neutron reflectometer and magnetic imaging technique

    NASA Astrophysics Data System (ADS)

    Hayashida, H.; Oku, T.; Kira, H.; Sakai, K.; Hiroi, K.; Ino, T.; Shinohara, T.; Imagawa, T.; Ohkawara, M.; Ohoyama, K.; Kakurai, K.; Takeda, M.; Yamazaki, D.; Oikawa, K.; Harada, M.; Miyata, N.; Akutsu, K.; Mizusawa, M.; Parker, J. D.; Matsumoto, Y.; Zhang, S.; Suzuki, J.; Soyama, K.; Aizawa, K.; Arai, M.

    2016-04-01

    We have been developing a 3He neutron spin filter (NSF) using the spin exchange optical pumping (SEOP) technique. The 3He NSF provides a high-energy polarized neutron beam with large beam size. Moreover the 3He NSF can work as a π-flipper for a polarized neutron beam by flipping the 3He nuclear spin using a nuclear magnetic resonance (NMR) technique. For NMR with the in-situ SEOP technique, the polarization of the laser must be reversed simultaneously because a non-reversed laser reduces the polarization of the spin-flipped 3He. To change the polarity of the laser, a half-wavelength plate was installed. The rotation angle of the half-wavelength plate was optimized, and a polarization of 97% was obtained for the circularly polarized laser. The 3He polarization reached 70% and was stable over one week. A demonstration of the 3He nuclear spin flip system was performed at the polarized neutron reflectometer SHARAKU (BL17) and NOBORU (BL10) at J-PARC. Off-specular measurement from a magnetic Fe/Cr thin film and magnetic imaging of a magnetic steel sheet were performed at BL17 and BL10, respectively.

  14. In Vivo Lung Morphometry with Accelerated Hyperpolarized 3He Diffusion MRI: A Preliminary Study

    PubMed Central

    Chang, Yulin V.; Quirk, James D.; Yablonskiy, Dmitriy A.

    2014-01-01

    Purpose Parallel imaging can be used to reduce imaging time and to increase the spatial coverage in hyperpolarized gas MRI of the lung. In this proof-of-concept study we investigate the effects of parallel imaging on the morphometric measurement of lung microstructure using diffusion MRI with hyperpolarized 3He. Methods Fully sampled and under-sampled multi-b diffusion data were acquired from human subjects using an 8-channel 3He receive coil. A parallel imaging reconstruction technique (GRAPPA) was used to reconstruct under-sampled k-space data. The morphometric results of the GRAPPA-reconstructed data were compared with the results of fully sampled data for three types of subjects: healthy volunteers, mild, and moderate COPD patients. Results Morphometric measurements varied only slightly at mild acceleration factors. The results were largely well preserved compared to fully sampled data for different lung conditions. Conclusion Parallel imaging, given sufficient signal-to-noise ratio, provides a reliable means to accelerate hyperpolarized-gas MRI with no significant difference in the measurement of lung morphometry from the fully sampled images. GRAPPA is a promising technique to significantly reduce imaging time and/or to improve the spatial coverage for the morphometric measurement with hyperpolarized gases. PMID:24799044

  15. Lithium glass scintillator neutron detector as an improved alternative to the standard 3 he proportional counter

    SciTech Connect

    Vladimir Popov, Pavel Degtiarenko

    2011-06-01

    Lithium glass scintillator made from 6Li-enriched substrate is a well known for its neutron detection capability. In spite of neutron interaction, cross section of 6Li happens to be lower than that of 3He. However, the neutron detection efficiency could be higher due to higher volume content of 6Li nuclear in the solid scintillator vs. gas filled proportional counter. At the same time, as lithium glass is sensitive to gamma and charge particle radiation, non-neutron radiation discrimination is required. Our detector is composed of two equal-size cylindrical Li(Ce) glass scintillators. The first one is high-sensitive to thermal neutrons GS-20 (6Li doped), the second one is GS-30 (7Li doped) type Scint-Gobain made lithium glass scintillator. Each of scintillators is coupled with R7400U Hamamatsu subminiature photomultiplier tube, and all assembly is fitted into NP100H 3He tube size. 6Li absorbs thermal neutrons releasing alpha particles and triton with 4.8 MeV total energy deposit inside the scintillator (equivalent to about ~1.3 MeV gamma energy depositions). Because 7Li isotope does not absorb thermal neutrons, and the physical properties of the two scintillators are virtually identical, the difference between these two scintillators could be used to provide neutron dose rate information. Results of study of neutron detector assembled of two Li(Ce) scintillators and NP100H moderator are presented

  16. Effects of Diffusion Time on Short-Range Hyperpolarized 3He Diffusivity Measurements in Emphysema

    PubMed Central

    Gierada, David S.; Woods, Jason C.; Bierhals, Andrew J.; Bartel, Seth T.; Ritter, Jon H.; Choong, Cliff K.; Das, Nitin A.; Hong, Cheng; Pilgram, Thomas K.; Chang, Yulin V.; Jacob, Richard E.; Hogg, James C.; Battafarano, Richard J.; Cooper, Joel D.; Meyers, Bryan F.; Patterson, G. Alexander; Yablonskiy, Dmitriy A.; Conradi, Mark S.

    2010-01-01

    Purpose To characterize the effect of diffusion time on short-range hyperpolarized 3He MR diffusion measurements across a wide range of emphysema severity. Materials and Methods 3He diffusion MR imaging was performed on 19 lungs or lobes resected from 18 subjects with varying degrees of emphysema using 3 diffusion times (1.6 msec, 5 msec, and 10 msec) at constant b value. Emphysema severity was quantified as the mean apparent diffusion coefficient (ADC) and as the percentage of pixels with ADC higher than multiple thresholds from 0.30–0.55 cm2/sec (ADC index). Quantitative histology (mean linear intercept) was obtained in 10 of the lung specimens from 10 of the subjects. Results The mean ADCs with diffusion times of 1.6, 5.0, and 10.0 msec were 0.46, 0.40, and 0.37 cm2/sec, respectively (P <0.0001, ANOVA). There was no relationship between the ADC magnitude and the effect of diffusion time on ADC values. Mean linear intercept correlated with ADC (r=0.91–0.94, P<0.001) and ADC index (r=0.78–0.92, P<0.01) at all diffusion times. Conclusion Decreases in ADC with longer diffusion time were unrelated to emphysema severity. The strong correlations between the ADC at all diffusion times tested and quantitative histology demonstrate that the ADC is a robust measure of emphysema. PMID:19787725

  17. High-relief glacial landscape evolution constrained by apatite 4He/3He thermochronometry

    NASA Astrophysics Data System (ADS)

    Shuster, D. L.; Sanders, J. W.; Cuffey, K. M.

    2009-12-01

    Apatite 4He/3He thermochronometry of bedrock samples collected from high-relief and heavily glaciated terrain near Milford Sound in Fiordland, New Zealand reveals clear differences between the cooling histories of high and low elevation samples. Across the region, the youngest apatite (U-Th)/He ages ~1 million years (Ma) generally occur at cirque floor elevations (~500-700 m elevation) rather than at sea level where (U-Th)/He ages approach ~2 Ma. Thermal histories constrained by 4He/3He thermochronometry of three vertically oriented samples collected along the headwall of a ~1100 meter deep cirque indicate that since ~1 Ma ago: (i) rocks presently located near the cirque rim (~1720 m elevation) have resided at temperatures <25 oC, while (ii) rocks at the floor of the cirque (~575 m elevation) continuously cooled from ~75-110 oC to the present surface temperature. These thermal histories indicate that most of the cirque relief developed over the last ~1 Ma and/or the sub-surface thermal field was highly perturbed during that time interval over an ~1 km horizontal scale. We will interpret sample cooling histories in conjunction with a 3-D model of subsurface temperature evolution in response to changes in topography. The goal is to constrain the rates and patterns of glacial valley development over the Quaternary.

  18. On the limits of spin-exchange optical pumping of {sup 3}He

    SciTech Connect

    Chen, W. C. Ye, Q.; Gentile, T. R.; Walker, T. G.; Babcock, E.

    2014-07-07

    We have obtained improvement in the {sup 3}He polarization achievable by spin-exchange optical pumping (SEOP). These results were primarily obtained in large neutron spin filter cells using diode bar lasers spectrally narrowed with chirped volume holographic gratings. As compared to our past results with lasers narrowed with diffraction gratings, we have observed between 5% and 11% fractional increase in the {sup 3}He polarization P{sub He}. We also report a comparable improvement in P{sub He} for two small cells, for which we would not have expected an increase from improved laser performance. In particular, prior extensive studies had indicated that the alkali-metal polarization was within 3% of unity in one of these cells. These results have impact on understanding the maximum P{sub He} achievable by SEOP, whether the origin of the improvement is from increased alkali-metal polarization or decreased temperature-dependent relaxation. We conclude that the most likely explanation for the improvement in P{sub He} is increased alkali-metal polarization. We have observed P{sub He} of between 0.80 and 0.85 in several large cells, which marks a new precedent for the polarization achievable by SEOP.

  19. Exploiting intrinsic triangular geometry in relativistic (3)He+Au collisions to disentangle medium properties.

    PubMed

    Nagle, J L; Adare, A; Beckman, S; Koblesky, T; Koop, J Orjuela; McGlinchey, D; Romatschke, P; Carlson, J; Lynn, J E; McCumber, M

    2014-09-12

    Recent results in d+Au and p+Pb collisions at RHIC and the LHC provide evidence for collective expansion and flow of the created medium. We propose a control set of experiments to directly compare particle emission patterns from p+Pb, d+Au, and ^{3}He+Au or t+Au collisions at the same sqrt[s_{NN}] . Using a Monte Carlo Glauber simulation we find that a ^{3}He or triton projectile, with a realistic wave function description, induces a significant intrinsic triangular shape to the initial medium. If the system lives long enough, this survives into a significant third-order flow moment v_{3} even with viscous damping. By comparing systems with one, two, and three initial hot spots, one could disentangle the effects from the initial spatial distribution of the deposited energy and viscous damping. These are key tools for answering the question of how small a droplet of matter is necessary to form a quark-gluon plasma described by nearly inviscid hydrodynamics.

  20. Effects of Diffusion Time on Short-Range Hyperpolarized 3He Diffusivity Measurements in Emphysema

    SciTech Connect

    Gierada, David S.; Woods, Jason C.; Bierhals, Andrew J.; Bartel, Seth T.; Ritter, Jon H.; Choong, Cliff K.; Das, Nitin A.; Hong, Cheng; Pilgram, Thomas K.; Chang, Yulin V.; Jacob, Rick E.; Hogg, James C.; Battafarano, Richard J.; Cooper, Joel D.; Meyers, Bryan F.; Patterson, G Alexander; Yablonskiy, Dmitriy A.; Conradi, Mark S.

    2009-09-28

    Purpose: To characterize the effect of diffusion time on short-range hyperpolarized 3He MR diffusion measurements across a wide range of emphysema severity. Materials and Methods: 3He diffusion MR imaging was performed on 19 lungs or lobes resected from 18 subjects with varying degrees of emphysema using 3 diffusion times (1.6 msec, 5 msec, and 10 msec) at constant b value. Emphysema severity was quantified as the mean apparent diffusion coefficient (ADC) and as the percentage of pixels with ADC higher than multiple thresholds from 0.30-0.55 cm2/sec (ADC index). Quantitative histology (mean linear intercept) was obtained in 10 of the lung specimens from 10 of the subjects. Results: The mean ADCs with diffusion times of 1.6, 5.0, and 10.0 msec were 0.46, 0.40, and 0.37 cm2/sec, respectively (P <0.0001, ANOVA). There was no relationship between the ADC magnitude and the effect of diffusion time on ADC values. Mean linear intercept correlated with ADC (r=0.91-0.94, P<0.001) and ADC index (r=0.78-0.92, P<0.01) at all diffusion times.