Science.gov

Sample records for 4-mm punch biopsy

  1. Best way to perform a punch biopsy.

    PubMed

    Domínguez-Cherit, Judith; Gutiérrez Mendoza, Daniela

    2015-04-01

    Nail punch biopsy is used to obtain a tissue sample for the diagnosis and treatment of nail diseases. The best results will be possible if the surgeon is familiar with the anatomy and physiology of the nail apparatus. A punch biopsy can be used in all regions of the nail apparatus in the presence or absence of nail plate. When the procedure is performed with a careful handling of the anatomic site and specimen, in most cases a successful diagnosis can be achieved. PMID:25828717

  2. Simulation of punch biopsies: a case study.

    PubMed

    Sessanna, Dennis; Stredney, Don; Hittle, Brad; Lambert, David

    2008-01-01

    As the incidence of skin cancer continues to rise, there is an increasing need for skilled practitioners that are proficient in identifying suspicious lesions and competent in acquiring biopsies that provide for optimal determination of malignancy and staging. We report on the development of a prototype simulation that emulates the basic procedures necessary to acquire a punch biopsy. The objective of this effort is to produce a low-cost, effective method to teach non-specialists, i.e., nurse practitioners, internists, etc., the optimal placement of the punch to obtain a biopsy for pathological analysis. The simulation can be utilized for synchronous sessions with remote experts, as well as asynchronous sessions for deliberate practice. The simulation is designed to allow for easy import of digital images of various lesions to promote use and present the wide pathological variance experienced in the clinic.

  3. [Standards for the punch biopsy of the prostate].

    PubMed

    Seitz, M; Schlenker, B; Gratzke, C; Weidlich, P; Stief, C G; Reich, O

    2007-01-25

    If, within the framework of screening examinations for the early detection of cancer of the prostate, the patient wishes a PSA test, the physician should accommodate him, but only after providing comprehensive information about the possible consequences and complications. If a certain threshold value is exceeded, a punch biopsy of the prostate is recommended. This procedure must be performed in accordance with accepted standards to enable, within the diagnostic chain, the reliable detection of a carcinoma of the prostate PMID:17615715

  4. [Image-guided punch biopsy of the prostate].

    PubMed

    Seitz, M; Gratzke, C; Stief, C; Tilki, D

    2012-09-01

    The diagnnosis of prostate cancer is still being made on the basis of biopsy samples taken from the prostate. After the clinical introduction of transrectal sonography almost 30 years ago, this technique has undergone some innovations and changes in its methods of performance. Improvements in the transponder and ultrasound generator are not yet at an end. In the mean time supplementary methods to the B-mode imaging are available that enable improvements in the diagnosis. Apart from ultrasound-based procedure such as C-TRUS/ANNA, contrast medium-enhanced ultrasound (CEUS) and sonoelastography, MRI-based methods are now available to further improve the diagnosis of prostate cancer. It remains to be seen which method will establish itself in the future with the highest degree of diagnostic certainty and an appropriate cost-use relationship. From the urologist's point, however, diagnosis of and therapy for prostate cancer must remain in the domaine of urology. PMID:22990951

  5. Skin punch biopsy explant culture for derivation of primary human fibroblasts.

    PubMed

    Vangipuram, Malini; Ting, Dennis; Kim, Sam; Diaz, Robert; Schüle, Birgitt

    2013-01-01

    Tissues and cell lines derived from an individual with disease are ideal sources to study disease-related cellular phenotypes. Patient-derived fibroblasts in this protocol have been successfully used in the derivation of induced pluripotent stem cells to model disease(1). Early passages of these fibroblasts can also be used for cell-based functional assays to study specific disease pathways, mechanisms(2) and subsequent drug screening approaches. The advantage of the presented protocol over enzymatic procedures are 1) the reproducibility of the technique from small amounts of tissue derived from older patients, e.g. patients affected with Parkinson's disease, 2) the technically simple approach over more challenging methodologies using enzymatic treatments, and 3) the time consideration: this protocol takes 15-20 min and can be performed immediately after biopsy arrival. Enzymatic treatments can take up to 4 hr and have the problems of overdigestion, reduction of cell viability and subsequent attachment of cells when not handled properly. This protocol describes the dissection and preparation of a 4-mm human skin biopsy for derivation of a fibroblast culture and has a very high success rate which is important when dealing with patient-derived tissue samples. In this culture, keratinocytes migrate out of the biopsy tissue within the first week after preparation. Fibroblasts appear 7-10 days after the first outgrowth of keratinocytes. DMEM high glucose media supplemented with 20% FBS favors the growth of fibroblasts over keratinocytes and fibroblasts will overgrow the keratinocytes. After 2 passages keratinocytes have been diluted out resulting in relatively homogenous fibroblast cultures which expresses the fibroblast marker SERPINH1 (HSP-47). Using this approach, 15-20 million fibroblasts can be derived in 4-8 weeks for cell banking. The skin dissection takes about 15-20 min, cells are then monitored once a day under the microscope, and media is changed every 2

  6. An In Vivo Comparison of Hemostatic Gelatin Matrix Products in a Porcine Spleen Biopsy-punch Model.

    PubMed

    Hutchinson, Richard W; Werrlein, Stephanie; Johns, Douglas B; Zhang, Gary; Clymer, Jeffrey W; Kocharian, Richard

    2015-11-01

    Flowable gelatin matrix products have established themselves as effective, easy-to-use hemostatic agents useful in a variety of surgical situations. A recently reformulated gelatin matrix, Surgiflo® (Ethicon Inc., Somerville, NJ), can be prepared quickly and provides consistent flow over an 8-hr. period. No in vivo studies have yet been reported comparing hemostasis with the new Surgiflo to other currently marketed flowable gelatin matrix products. This study was conducted to determine whether Surgiflo in actual use has hemostatic qualities different from another commercial gelatin matrix. An in vivo model based on porcine spleen biopsy punch-induced bleeding was used to compare Surgiflo and Floseal™ (Baxter Healthcare Corporation, Hayward, CA), both with thrombin. Time required to achieve hemostasis and proportion of sites achieving hemostasis within 30 s were determined for both hemostatic agents and a control of saline-soaked gauze. Results were stratified by the degree of initial bleeding (mild, moderate, severe). Hemostasis was achieved within 3 minutes at all sites for both test products regardless of level of initial bleeding, and control sites continued bleeding past 10 minutes. There were no statistically significant differences between Surgiflo and Floseal for either mean time to hemostasis or proportion of sites hemostatic within 30 s. In this realistic in vivo model both gelatin matrix products were effective, and there were no significant differences observed in hemostatic efficacy between Surgiflo and Floseal. Other factors, such as ease of preparation and application, in-use stability, and economic considerations may affect a surgeon's decision in selection of a desirable hemostatic product.

  7. Implementation of a non-lethal biopsy punch monitoring program for mercury in smallmouth bass, Micropterus dolomieu Lacepède, from the Eleven Point River, Missouri

    USGS Publications Warehouse

    Ackerson, J.R.; Schmitt, C. J.; McKee, M.J.; Brumbaugh, W.G.

    2013-01-01

    A non-lethal biopsy method for monitoring mercury (Hg) concentrations in smallmouth bass (Micropterus dolomieu; smallmouth) from the Eleven Point River in southern Missouri USA was evaluated. A biopsy punch was used to remove a muscle tissue plug from the area immediately below the anterior dorsal fin of 31 smallmouth. An additional 35 smallmouth (controls) were held identically except that no tissue plug was removed. After sampling, all fish were held in a concrete hatchery raceway for 6 weeks. Mean survival at the end of the holding period was 97 % for both groups. Smallmouth length, weight and Fulton’s condition factor at the end of the holding period were also similar between plugged and non-plugged controls, indicating that the biopsy procedure had minimal impact on growth under these conditions. Tissue plug Hg concentrations were similar to smallmouth Hg data obtained in previous years by removing the entire fillet for analysis.

  8. The GBT 4mm Receiver

    NASA Astrophysics Data System (ADS)

    Frayer, David T.; White, S.; Watts, G.; Stennes, M.; Maddalena, R. J.; Simon, R.; Pospieszalski, M.; Bryerton, E.

    2013-01-01

    The new 4mm receiver (67--93 GHz) for the Robert C. Byrd Green Bank Telescope (GBT) was built to take advantage of the improved surface accuracy of the dish. The low frequency end of the 3mm atmospheric window is not available with ALMA (<84 GHz), and the sensitivity of the GBT is better than any other facility within this band. We discuss the design and performance of this new receiver for the GBT, and highlight the science opportunities available with the instrument. The National Radio Astronomy Observatory is a facility of the National Science Foundation operated under cooperative agreement by Associated Universities, Inc.

  9. Biopsy

    MedlinePlus

    Tissue sampling ... biopsy is called a percutaneous biopsy. It removes tissue using a needle attached to a hollow tube ... The needle is passed several times through the tissue being examined. The doctor uses the needle to ...

  10. Dermal vacuoles in two biopsies of psoriasis.

    PubMed

    Ayva, Sebnem; Erkek, Emel; Atasoy, Pinar

    2008-11-01

    Two patients presented with cutaneous lesions clinically typical of psoriasis. The first case was a 38-year-old man and the second was a 51-year-old woman. To confirm the diagnosis, 4-mm punch biopsy samples were obtained from both patients from the lesions on the knees. Histology in both cases was in favour of psoriasis and also revealed empty vacuoles in the papillary dermis, concentrated at sites of intense lymphocyte infiltration. The empty vacuoles resembled true fat cells or fat globules. They did not reveal positive immunostaining with CD34 antigen, suggesting that they were not lined by endothelial cells. Final histological diagnosis was psoriasis associated with dermal vacuolization.

  11. Diagnosis of Cutaneous Leishmaniasis: Why Punch When You Can Scrape?

    PubMed Central

    Saab, Mario; El Hage, Hussein; Charafeddine, Khalil; Habib, Robert H.; Khalifeh, Ibrahim

    2015-01-01

    Cutaneous leishmaniasis (CL) has been introduced to the Leishmania under-endemic Lebanese population in an uncontrolled manner as a result of recent large-scale displacement of refugees from endemic Syria. Accordingly, a quick and reliable method to diagnose CL is essential. Matched punch biopsies and air-dried scrapings on 72 patients were obtained. Scrapings were collected in two forms: thick drop (N = 33) or thin smear (N = 39). Clinical information was recorded. Sections of punch biopsies and scrapings were stained and examined microscopically. Polymerase chain reaction (PCR) was performed on both scraping forms and biopsies. The diagnostic sensitivity of the tests performed revealed that microscopy in conjunction with PCR on punch biopsies was the most sensitive test (93%) overall. However, taken individually, microscopy and PCR yielded the highest sensitivities when performed on drop scrapings (63% and 85%, respectively), and not smear scrapings (38% and 56%, respectively) as compared with the punch biopsies (44% and 83%, respectively). Microscopic concordance for punch biopsies and drop scrapings was present in 25 of 33 cases. Concordance was predicted only by the high/low parasitic index (PI: 3.1 ± 1.7 and 0.4 ± 0.5, respectively; P < 0.05). Herein, we optimized a novel rapid method for reliable diagnosis of CL based on drop scrapings with good agreement with the gold standard punch biopsy technique. PMID:25561563

  12. Acceleration of cutaneous healing by electrical stimulation: degenerate electrical waveform down-regulates inflammation, up-regulates angiogenesis and advances remodeling in temporal punch biopsies in a human volunteer study.

    PubMed

    Sebastian, Anil; Syed, Farhatullah; Perry, Donna; Balamurugan, Vinayagapriya; Colthurst, James; Chaudhry, Iskander H; Bayat, Ardeshir

    2011-11-01

    We previously demonstrated the beneficial effect of a novel electrical stimulation (ES) waveform, degenerate wave (DW) on skin fibroblasts, and now hypothesize that DW can enhance cutaneous wound healing in vivo. Therefore, a punch biopsy was taken from the upper arm of 20 volunteers on day 0 and repeated on day 14 (NSD14). A contralateral upper arm biopsy was taken on day 0 and treated with DW for 14 days prior to a repeat biopsy on day 14 (ESD14). A near-completed inflammatory stage of wound healing in ESD14, compared to NSD14 was demonstrated by up-regulation of interleukin-10 and vasoactive intestinal peptide using quantitative real time polymerase chain reaction and down-regulation of CD3 by immunohistochemistry (IHC) (p < 0.05). In addition to up-regulation (p < 0.05) of mRNA transcripts for re-epithelialization and angiogenesis, IHC showed significant overexpression (p < 0.05) of CD31 (15.5%), vascular endothelial growth factor (66%), and Melan A (8.6 cells/0.95 mm²) in ESD14 compared to NSD14 (9.5%, 38% and 4.3 cells/0.95 mm², respectively). Furthermore, granulation tissue formation (by hematoxylin and eosin staining), and myofibroblastic proliferation demonstrated by alpha-smooth muscle actin (62.7%) plus CD3+ T lymphocytes (8.1%) showed significant up-regulation (p < 0.05) in NSD14. In the remodeling stage, mRNA transcripts for fibronectin, collagen IV (by IHC, 14.1%) and mature collagen synthesis (by Herovici staining, 71.44%) were significantly up-regulated (p < 0.05) in ESD14. Apoptotic (TUNEL assay) and proliferative cells (Ki67) were significantly up-regulated (p < 0.05) in NSD14 (5.34 and 11.9 cells/0.95 mm²) while the proliferation index of ESD14 was similar to normal skin. In summary, cutaneous wounds receiving DW electrical stimulation display accelerated healing seen by reduced inflammation, enhanced angiogenesis and advanced remodeling phase.

  13. [Enforcement of type M 20 cal. 4 mm cartridges].

    PubMed

    Dobosz, Tadeusz; Jaworski, Ryszard; Kawecki, Jerzy; Semiczek, Wiesław; Trnka, Jakub

    2002-01-01

    The aim of the paper was to investigate and compare the speed and energy of a bullet from 4 mm cal. cartridges of central ignition type M20, both original and transformed by addition of different kinds of propellants. Original cartridges are characterized by an average speed of the bullet of 144 m/s and average energy of 4.8 J. After transformation by the addition of on an average 31.3 mg of smokeless powder from a cartridge type LR'22, a maximum bullet speed of 299 m/s (average) and maximum energy of 21.2 joule (average) were reached. Our test showed that shots using transformed ammunition type M 20 cal. 4 mm can be dangerous for both health and life. Multiple M20 shot wounds may be very similar to single shot wounds caused by a shotshell cartridge fired from a shotgun weapon.

  14. Sun Packs Double Punch

    NASA Video Gallery

    On August 3, the sun packed a double punch, emitting a M6.0-class flare at 9:43 am EDT. This video is of the second, slightly stronger M9.3-class flare at 11:41 pm EDT. Both flares had significant ...

  15. Punch card programmable microfluidics.

    PubMed

    Korir, George; Prakash, Manu

    2015-01-01

    Small volume fluid handling in single and multiphase microfluidics provides a promising strategy for efficient bio-chemical assays, low-cost point-of-care diagnostics and new approaches to scientific discoveries. However multiple barriers exist towards low-cost field deployment of programmable microfluidics. Incorporating multiple pumps, mixers and discrete valve based control of nanoliter fluids and droplets in an integrated, programmable manner without additional required external components has remained elusive. Combining the idea of punch card programming with arbitrary fluid control, here we describe a self-contained, hand-crank powered, multiplex and robust programmable microfluidic platform. A paper tape encodes information as a series of punched holes. A mechanical reader/actuator reads these paper tapes and correspondingly executes operations onto a microfluidic chip coupled to the platform in a plug-and-play fashion. Enabled by the complexity of codes that can be represented by a series of holes in punched paper tapes, we demonstrate independent control of 15 on-chip pumps with enhanced mixing, normally-closed valves and a novel on-demand impact-based droplet generator. We demonstrate robustness of operation by encoding a string of characters representing the word "PUNCHCARD MICROFLUIDICS" using the droplet generator. Multiplexing is demonstrated by implementing an example colorimetric water quality assays for pH, ammonia, nitrite and nitrate content in different water samples. With its portable and robust design, low cost and ease-of-use, we envision punch card programmable microfluidics will bring complex control of microfluidic chips into field-based applications in low-resource settings and in the hands of children around the world. PMID:25738834

  16. Punch Card Programmable Microfluidics

    PubMed Central

    Korir, George; Prakash, Manu

    2015-01-01

    Small volume fluid handling in single and multiphase microfluidics provides a promising strategy for efficient bio-chemical assays, low-cost point-of-care diagnostics and new approaches to scientific discoveries. However multiple barriers exist towards low-cost field deployment of programmable microfluidics. Incorporating multiple pumps, mixers and discrete valve based control of nanoliter fluids and droplets in an integrated, programmable manner without additional required external components has remained elusive. Combining the idea of punch card programming with arbitrary fluid control, here we describe a self-contained, hand-crank powered, multiplex and robust programmable microfluidic platform. A paper tape encodes information as a series of punched holes. A mechanical reader/actuator reads these paper tapes and correspondingly executes operations onto a microfluidic chip coupled to the platform in a plug-and-play fashion. Enabled by the complexity of codes that can be represented by a series of holes in punched paper tapes, we demonstrate independent control of 15 on-chip pumps with enhanced mixing, normally-closed valves and a novel on-demand impact-based droplet generator. We demonstrate robustness of operation by encoding a string of characters representing the word “PUNCHCARD MICROFLUIDICS” using the droplet generator. Multiplexing is demonstrated by implementing an example colorimetric water quality assays for pH, ammonia, nitrite and nitrate content in different water samples. With its portable and robust design, low cost and ease-of-use, we envision punch card programmable microfluidics will bring complex control of microfluidic chips into field-based applications in low-resource settings and in the hands of children around the world. PMID:25738834

  17. Punch card programmable microfluidics.

    PubMed

    Korir, George; Prakash, Manu

    2015-01-01

    Small volume fluid handling in single and multiphase microfluidics provides a promising strategy for efficient bio-chemical assays, low-cost point-of-care diagnostics and new approaches to scientific discoveries. However multiple barriers exist towards low-cost field deployment of programmable microfluidics. Incorporating multiple pumps, mixers and discrete valve based control of nanoliter fluids and droplets in an integrated, programmable manner without additional required external components has remained elusive. Combining the idea of punch card programming with arbitrary fluid control, here we describe a self-contained, hand-crank powered, multiplex and robust programmable microfluidic platform. A paper tape encodes information as a series of punched holes. A mechanical reader/actuator reads these paper tapes and correspondingly executes operations onto a microfluidic chip coupled to the platform in a plug-and-play fashion. Enabled by the complexity of codes that can be represented by a series of holes in punched paper tapes, we demonstrate independent control of 15 on-chip pumps with enhanced mixing, normally-closed valves and a novel on-demand impact-based droplet generator. We demonstrate robustness of operation by encoding a string of characters representing the word "PUNCHCARD MICROFLUIDICS" using the droplet generator. Multiplexing is demonstrated by implementing an example colorimetric water quality assays for pH, ammonia, nitrite and nitrate content in different water samples. With its portable and robust design, low cost and ease-of-use, we envision punch card programmable microfluidics will bring complex control of microfluidic chips into field-based applications in low-resource settings and in the hands of children around the world.

  18. Prostate biopsy

    MedlinePlus

    ... prostate biopsy; Fine needle biopsy of the prostate; Core biopsy of the prostate; Targeted prostate biopsy; Prostate biopsy - transrectal ultrasound (TRUS); Stereotactic transperineal prostate biopsy (STPB)

  19. Portable punch and die jig

    DOEpatents

    Lewandowski, Edward F.; Anderson, Petrus A.

    1978-01-01

    A portable punch and die jig includes a U-shaped jig of predetermined width having a slot of predetermined width in the base thereof extending completely across the width of the jig adapted to fit over the walls of rectangular tubes and a punch and die assembly disposed in a hole extending through the base of the jig communicating with the slot in the base of the jig for punching a hole in the walls of the rectangular tubes at precisely determined locations.

  20. 21 CFR 882.4750 - Skull punch.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Skull punch. 882.4750 Section 882.4750 Food and... NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4750 Skull punch. (a) Identification. A skull punch is a device used to punch holes through a patient's skull to allow fixation of cranioplasty plates...

  1. 21 CFR 882.4750 - Skull punch.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Skull punch. 882.4750 Section 882.4750 Food and... NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4750 Skull punch. (a) Identification. A skull punch is a device used to punch holes through a patient's skull to allow fixation of cranioplasty plates...

  2. 21 CFR 882.4750 - Skull punch.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Skull punch. 882.4750 Section 882.4750 Food and... NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4750 Skull punch. (a) Identification. A skull punch is a device used to punch holes through a patient's skull to allow fixation of cranioplasty plates...

  3. 21 CFR 882.4750 - Skull punch.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Skull punch. 882.4750 Section 882.4750 Food and... NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4750 Skull punch. (a) Identification. A skull punch is a device used to punch holes through a patient's skull to allow fixation of cranioplasty plates...

  4. 21 CFR 882.4750 - Skull punch.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Skull punch. 882.4750 Section 882.4750 Food and... NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4750 Skull punch. (a) Identification. A skull punch is a device used to punch holes through a patient's skull to allow fixation of cranioplasty plates...

  5. Metrics for Key Punch Operators.

    ERIC Educational Resources Information Center

    Cooper, Gloria S., Ed.; Magisos, Joel H., Ed.

    Designed to meet the job-related metric measurement needs of key punch operator students, this instructional package is one of three for the business and office occupations cluster, part of a set of 55 packages for metric instruction in different occupations. The package is intended for students who already know the occupational terminology,…

  6. PUNCH: Population Characterization of Heterogeneity.

    PubMed

    Tunc, Birkan; Ghanbari, Yasser; Smith, Alex R; Pandey, Juhi; Browne, Aaron; Schultz, Robert T; Verma, Ragini

    2014-09-01

    Neuropsychiatric disorders are notoriously heterogeneous in their presentation, which precludes straightforward and objective description of the differences between affected and typical populations that therefore makes finding reliable biomarkers a challenge. This difficulty underlines the need for reliable methods to capture sample characteristics of heterogeneity using a single continuous measure, incorporating the multitude of scores used to describe different aspects of functioning. This study addresses this challenge by proposing a general method of identifying and quantifying the heterogeneity of any clinical population using a severity measure called the PUNCH (Population Characterization of Heterogeneity). PUNCH is a decision level fusion technique to incorporate decisions of various phenotypic scores, while providing interpretable weights for scores. We provide applications of our framework to simulated datasets and to a large sample of youth with Autism Spectrum Disorder (ASD). Next we stratify PUNCH scores in our ASD sample and show how severity moderates findings of group differences in diffusion weighted brain imaging data; more severely affected subgroups of ASD show expanded differences compared to age and gender matched healthy controls. Results demonstrate the ability of our measure in quantifying the underlying heterogeneity of the clinical samples, and suggest its utility in providing researchers with reliable severity assessments incorporating population heterogeneity.

  7. An efficient method of measuring the 4 mm helmet output factor for the Gamma Knife

    NASA Astrophysics Data System (ADS)

    Ma, Lijun; Li, X. Allen; Yu, Cedric X.

    2000-03-01

    It is essential to have accurate measurements of the 4 mm helmet output factor in the treatment of trigeminal neuralgia patients using the Gamma Knife. Because of the small collimator size and the sharp dose gradient at the beam focus, this measurement is generally tedious and difficult. We have developed an efficient method of measuring the 4 mm helmet output factor using regular radiographic films. The helmet output factor was measured by exposing a single Kodak XV film in the standard Leksell spherical phantom using the 18 mm helmet with 30-40 of its plug collimators replaced by the 4 mm plug collimators. The 4 mm helmet output factor was measured to be 0.876 ± 0.009. This is in excellent agreement with our EGS4 Monte Carlo simulated value of 0.876 ± 0.005. This helmet output factor value also agrees with more tedious TLD, diode and radiochromic film measurements that were each obtained using two separate measurements with the 18 mm helmet and the 4 mm helmet respectively. The 4 mm helmet output factor measured by the diode was 0.884 ± 0.016, and the TLD measurement was 0.890 ± 0.020. The radiochromic film measured value was 0.870 ± 0.018. Because a single-exposure measurement was performed instead of a double-exposure measurement, most of the systematic errors that appeared in the double-exposure measurements due to experimental setup variations were cancelled out. Consequently, the 4 mm helmet output factor is more precisely determined by the single-exposure approach. Therefore, routine measurement and quality assurance of the 4 mm helmet output factor of the Gamma Knife could be efficiently carried out using the proposed single-exposure technique.

  8. Task Shifting and Skin Punch for the Histologic Diagnosis of Kaposi’s Sarcoma in Sub-Saharan Africa: A Public Health Solution to a Public Health Problem

    PubMed Central

    Laker-Oketta, Miriam; Wenger, Megan; Semeere, Aggrey; Castelnuovo, Barbara; Kambugu, Andrew; Lukande, Robert; Asirwa, F. Chite; Busakhala, Naftali; Buziba, Nathan; Diero, Lameck; Wools-Kaloustian, Kara; Strother, R. Matthew; Bwana, Mwebesa; Muyindike, Winnie; Amerson, Erin; Mbidde, Edward; Maurer, Toby; Martin, Jeffrey

    2015-01-01

    Fueled by HIV, sub-Saharan Africa has the highest incidence of Kaposi’s sarcoma (KS) in the world. Despite this, most KS diagnosis in the region is on clinical grounds. Where biopsy is available, it has traditionally been excisional and performed by surgeons, resulting in multiple appointments, follow-up visits for suture removal, and substantial costs. We hypothesized a simpler approach — skin punch biopsy — would make histologic diagnosis more accessible. To address this, we provided training and equipment for skin punch biopsy of suspected KS to three HIV clinics in East Africa. The procedure consisted of local anesthesia followed by a disposable cylindrical punch blade to obtain specimen. Hemostasis is facilitated by Gelfoam®. Patients remove the dressing after four days. From 2007 to 2013, 2799 biopsies were performed. Although originally targeted to physicians, biopsies were performed predominantly by nurses (62%), followed by physicians (15%), clinical officers (12%) and technicians (11%). There were no reports of recurrent bleeding or infection. After minimal training and provision of inexpensive equipment ($3.06 per biopsy), HIV clinics in East Africa can integrate same-day skin punch biopsy for suspected KS. Task shifting from physician to non-physician greatly increases access. Skin punch biopsy should be part of any HIV clinic’s essential procedures. This example of task shifting may also be applicable to the diagnosis of other cancers (e.g., breast) in resource-limited settings. PMID:25765812

  9. Task Shifting and Skin Punch for the Histologic Diagnosis of Kaposi's Sarcoma in Sub-Saharan Africa: A Public Health Solution to a Public Health Problem.

    PubMed

    Laker-Oketta, Miriam O; Wenger, Megan; Semeere, Aggrey; Castelnuovo, Barbara; Kambugu, Andrew; Lukande, Robert; Asirwa, F Chite; Busakhala, Naftali; Buziba, Nathan; Diero, Lameck; Wools-Kaloustian, Kara; Strother, Robert Matthew; Bwana, Mwebesa; Muyindike, Winnie; Amerson, Erin; Mbidde, Edward; Maurer, Toby; Martin, Jeffrey

    2015-01-01

    Fueled by HIV, sub-Saharan Africa has the highest incidence of Kaposi's sarcoma (KS) in the world. Despite this, KS diagnosis in the region is based mostly on clinical grounds. Where biopsy is available, it has traditionally been excisional and performed by surgeons, resulting in multiple appointments, follow-up visits for suture removal, and substantial costs. We hypothesized that a simpler approach - skin punch biopsy - would make histologic diagnosis more accessible. To address this, we provided training and equipment for skin punch biopsy of suspected KS to three HIV clinics in East Africa. The procedure consisted of local anesthesia followed by a disposable cylindrical punch blade to obtain specimens. Hemostasis is facilitated by Gelfoam®. Patients removed the dressing after 4 days. From 2007 to 2013, 2,799 biopsies were performed. Although originally targeted to be used by physicians, biopsies were performed predominantly by nurses (62%), followed by physicians (15%), clinical officers (12%) and technicians (11%). There were no reports of recurrent bleeding or infection. After minimal training and provision of inexpensive equipment (USD 3.06 per biopsy), HIV clinics in East Africa can integrate same-day skin punch biopsy for suspected KS. Task shifting from physician to non-physician greatly increases access. Skin punch biopsy should be part of any HIV clinic's essential procedures. This example of task shifting may also be applicable to the diagnosis of other cancers (e.g., breast) in resource-limited settings. PMID:25765812

  10. Miniature specimen shear punch test for UHMWPE used in total joint replacements.

    PubMed

    Kurt, S M; Jewett, C W; Bergström, J S; Foulds, J R; Edidin, A A

    2002-05-01

    Despite the critical role that shear is hypothesized to play in the damage modes that limit the performance of total hip and knee replacements, the shear behavior of ultra-high molecular weight polyethylene (UHMWPE) remains poorly understood, especially after oxidative degradation or radiation crosslinking. In the present study, we developed the miniature specimen (0.5 mm thickness x 6.4mm diameter) shear punch test to evaluate the shear behavior of UHMWPE used in total joint replacement components. We investigated the shear punch behavior of virgin and crosslinked stock materials, as well as of UHMWPE from tibial implants that were gamma-irradiated in air and shelf aged for up to 8.5 years. Finite element analysis, scanning electron microscopy, and interrupted testing were conducted to aid in the interpretation of the shear punch load-displacement curves. The shear punch load-displacement curves exhibited similar distinctive features. Following toe-in, the load-displacement curves were typically bilinear, and characterized by an initial stiffness, a transition load, a hardening stiffness, and a peak load. The finite element analysis established that the initial stiffness was proportional to the elastic modulus of the UHMWPE, and the transition load of the bilinear curve reflected the development of a plastically deforming zone traversing through the thickness of the sample. Based on our observations, we propose two interpretations of the peak load during the shear punch test: one theory is based on the initiation of crystalline plasticity, the other based on the transition from shear to tension during the tests. Due to the miniature specimen size, the shear punch test offers several potential advantages over bulk test methods, including the capability to directly measure shear behavior, and quite possibly infer ultimate uniaxial behavior as well, from shelf aged and retrieved UHMWPE components. Thus, the shear punch test represents an effective and complementary

  11. Kidney biopsy

    MedlinePlus

    Renal biopsy; Biopsy - kidney ... Barisoni L, Arend LJ, Thomas DB. Introduction to renal biopsy. In: Zhou M, Mari-Galluzzi C, eds. ... Saunders; 2015:chap 7. Topham PS, Chen Y. Renal biopsy. In: Johnson RJ, Feehally J, Floege J, ...

  12. Gum biopsy

    MedlinePlus

    Biopsy - gingiva (gums) ... used to close the opening created for the biopsy. ... to eat for a few hours before the biopsy. ... Risks for this procedure include: Bleeding from the biopsy site Infection of the gums Soreness

  13. Science in mid-Victorian Punch.

    PubMed

    Noakes, Richard

    2002-09-01

    This article examines the scientific content of the most famous comic journal of the Victorian period: Punch. Concentrating on the first three decades of the periodical (1841-1871), I show that Punch usually engaged with science that was highly topical, of consequence to the lives of its bourgeois readers, and suitable for comic interpretation. But Punch's satire of scientific topics was highly complex. It often contained allusions to non-scientific topics, and its engagement with science ranged from the utterly comic to the sharply critical. Punch prompted readers to think as well as laugh about science, and probably shaped their scientific education more than we think.

  14. Micro-Hole Multi-Point Punching System Using Punch and Die Made by EDM

    NASA Astrophysics Data System (ADS)

    Broomfield, Mark; Mori, Toshihiko; Mikuriya, Teruaki; Tachibana, Kazushi

    In this research a multi-point micro punch and die system was developed. The process of electric discharge machining (EDM) was used to produce both the punch and die. The punches were machined from a 5 mm diameter tungsten and a 10 mm diameter tool steel round rods by wire electric discharge machining (WEDM), using a 200 µm diameter wire electrode. The die holes were made using the punch as the electrode. The EDM process of the holes was carried out on a newly developed desktop EDM machine. The punch and die placed on a micro-die set and then on a micro press were used to produce micro-holes using an automatic control system developed for this process. Experiments to produce 50 µm to 67 µm square micro-holes on 50 µm thick aluminum, 30 µm thick copper and 20 µm thick stainless steel foils were conducted. The capabilities of multi-point punching using the tungsten punch and a tool steel punch were examined and tungsten was chosen as the material of choice for making the punch tool. A scanning electron microscope confirmed that the holes produced are clean, and the sheared surfaces smooth. The punch tool showed no signs of deformation or cracks even after repeated punching.

  15. Influence of Die and Punch Profile Radii on Deep Drawing Force and Punch Load- Displacement Diagram

    NASA Astrophysics Data System (ADS)

    Mansourinejad, M.; Mirzakhani, B.; Pishbin, H.; Amadeh, A.; Farshchian, B.

    2011-01-01

    In this study, circumstances of formation and development of different zones of cup during the deep drawing process is predicted using geometrical relationships between punch and some process variables. Also, relationships between bending angle, die and punch profile radii, strain in flange and die profile regions are obtained at a given punch travel. In addition, deformation force components are calculated and based on the obtained relationships punch force-displacement diagrams for various punch and die profile radii are plotted. The effects of punch and die profile radii on these diagrams are then discussed. According to the proposed analysis, the effects of die and punch profile radii on deep drawing force are compared with each other. It is concluded that the die profile radius affects not only bending and unbending forces but also the actual drawing ratio while the punch profile radius has only an insignificant effect on actual drawing ratio. Also, effects of die and punch profile radii on punch stroke at maximum load are the same.

  16. Liver biopsy

    MedlinePlus

    Biopsy - liver; Percutaneous biopsy ... the biopsy needle to be inserted into the liver. This is often done by using ultrasound. The ... the chance of damage to the lung or liver. The needle is removed quickly. Pressure will be ...

  17. Biopsy - polyps

    MedlinePlus

    Polyp biopsy ... are treated is the colon. How a polyp biopsy is done depends on the location: Colonoscopy or flexible sigmoidoscopy explores the large bowel Colposcopy-directed biopsy examines the vagina and cervix Esophagogastroduodenoscopy (EGD) or ...

  18. Kidney Biopsy

    MedlinePlus

    ... right diagnosis. [ Top ] What should a person do days before a kidney biopsy? Days before the procedure, ... Top ] What can a person expect on the day of the kidney biopsy? A person should arrive ...

  19. Tongue biopsy

    MedlinePlus

    Biopsy - tongue ... A tongue biopsy can be done using a needle. You will get numbing medicine at the place where the ... provider will gently stick the needle into the tongue and remove a tiny piece of tissue. Some ...

  20. Effect of punch tip geometry and embossment on the punch tip adherence of a model ibuprofen formulation.

    PubMed

    Roberts, Matthew; Ford, James L; MacLeod, Graeme S; Fell, John T; Smith, George W; Rowe, Philip H; Dyas, A Mark

    2004-07-01

    The sticking of a model ibuprofen-lactose formulation with respect to compaction force, punch tip geometry and punch tip embossment was assessed. Compaction was performed at 10, 25 or 40 kN using an instrumented single-punch tablet press. Three sets of 'normal' concave punches were used to evaluate the influence of punch curvature and diameter. The punches were 10, 11 and 12 mm in diameter, respectively. The 10-mm punch was embossed with a letter 'A' logo to assess the influence of an embossment on sticking. Flat-faced punches (12.5 mm) were used for comparison with the concave tooling. Surface profiles (Taylor Hobson Talysurf 120) of the upper punch faces were obtained to evaluate the surface quality of the tooling used. Following compaction, ibuprofen attached to the upper punch face was quantified by spectroscopy. Increasing punch curvature from flat-faced punches to concave decreased sticking. Altering punch diameter of the concave punches had no effect on sticking when expressed as microg mm(-2). The embossed letter 'A' logo increased sticking considerably owing to the probable concentration of shear stresses at the lateral faces of the embossed logo.

  1. Liver Biopsy

    MedlinePlus

    ... PDF, 341 KB)​​​​. Alternate Language URL Español Liver Biopsy Page Content On this page: What is a ... to Remember Clinical Trials What is a liver biopsy? A liver biopsy is a procedure that involves ...

  2. Limits on Venus' SO2 abundance profile from interferometric observations at 3.4 mm wavelength

    NASA Technical Reports Server (NTRS)

    Good, J. C.; Schloerb, F. P.

    1983-01-01

    The role of SO2 in the chemistry of the clouds of Venus has been investigated by deducing its mixing ratio profile in the atmosphere through millimeter wavelength interferometric measurements of the planet's limb darkening. The first zero crossing of the Venus visibility function was measured to be 0.6221 + or - 0.0007 at a wavelength of 3.4 mm, using a reference radius for Venus of 6100 km. This measurement constrains the amount of limb darkening and shows that the high concentrations of SO2 found in the lower atmosphere do not persist above an altitude of 42 km. Thus, a sink for SO2 exists below the level of the lowest cloud deck.

  3. Miniature specimen shear punch test for UHMWPE used in total joint replacements.

    PubMed

    Kurt, S M; Jewett, C W; Bergström, J S; Foulds, J R; Edidin, A A

    2002-05-01

    Despite the critical role that shear is hypothesized to play in the damage modes that limit the performance of total hip and knee replacements, the shear behavior of ultra-high molecular weight polyethylene (UHMWPE) remains poorly understood, especially after oxidative degradation or radiation crosslinking. In the present study, we developed the miniature specimen (0.5 mm thickness x 6.4mm diameter) shear punch test to evaluate the shear behavior of UHMWPE used in total joint replacement components. We investigated the shear punch behavior of virgin and crosslinked stock materials, as well as of UHMWPE from tibial implants that were gamma-irradiated in air and shelf aged for up to 8.5 years. Finite element analysis, scanning electron microscopy, and interrupted testing were conducted to aid in the interpretation of the shear punch load-displacement curves. The shear punch load-displacement curves exhibited similar distinctive features. Following toe-in, the load-displacement curves were typically bilinear, and characterized by an initial stiffness, a transition load, a hardening stiffness, and a peak load. The finite element analysis established that the initial stiffness was proportional to the elastic modulus of the UHMWPE, and the transition load of the bilinear curve reflected the development of a plastically deforming zone traversing through the thickness of the sample. Based on our observations, we propose two interpretations of the peak load during the shear punch test: one theory is based on the initiation of crystalline plasticity, the other based on the transition from shear to tension during the tests. Due to the miniature specimen size, the shear punch test offers several potential advantages over bulk test methods, including the capability to directly measure shear behavior, and quite possibly infer ultimate uniaxial behavior as well, from shelf aged and retrieved UHMWPE components. Thus, the shear punch test represents an effective and complementary

  4. Strength of footing with punching shear preventers.

    PubMed

    Lee, Sang-Sup; Moon, Jiho; Park, Keum-Sung; Bae, Kyu-Woong

    2014-01-01

    The punching shear failure often governs the strength of the footing-to-column connection. The punching shear failure is an undesirable failure mode, since it results in a brittle failure of the footing. In this study, a new method to increase the strength and ductility of the footing was proposed by inserting the punching shear preventers (PSPs) into the footing. The validation and effectiveness of PSP were verified through a series of experimental studies. The nonlinear finite element analysis was then performed to demonstrate the failure mechanism of the footing with PSPs in depth and to investigate the key parameters that affect the behavior of the footing with PSPs. Finally, the design recommendations for the footing with PSPs were suggested. PMID:25401141

  5. Strength of Footing with Punching Shear Preventers

    PubMed Central

    Lee, Sang-Sup; Moon, Jiho; Park, Keum-Sung; Bae, Kyu-Woong

    2014-01-01

    The punching shear failure often governs the strength of the footing-to-column connection. The punching shear failure is an undesirable failure mode, since it results in a brittle failure of the footing. In this study, a new method to increase the strength and ductility of the footing was proposed by inserting the punching shear preventers (PSPs) into the footing. The validation and effectiveness of PSP were verified through a series of experimental studies. The nonlinear finite element analysis was then performed to demonstrate the failure mechanism of the footing with PSPs in depth and to investigate the key parameters that affect the behavior of the footing with PSPs. Finally, the design recommendations for the footing with PSPs were suggested. PMID:25401141

  6. Wiring harnesses documented by punched-card technique

    NASA Technical Reports Server (NTRS)

    Hicks, W. W.; Kloezeman, W. G.

    1970-01-01

    Cards representing a connector are punched, sorted, and then used to printout wiring documentation for that connector. When wiring changes are made, new cards are punched and the wiring documentation is reprinted to reflect the latest configuration.

  7. Endothelial cell seeding of a 4-mm I.D. polyurethane vascular graft.

    PubMed

    Fields, Charles; Cassano, Anthony; Allen, Cynthia; Meyer, Andrew; Pawlowski, Kristin J; Bowlin, Gary L; Rittgers, Stanley E; Szycher, Michael

    2002-07-01

    We evaluated the extent (luminal coverage) of the endothelial cell (EC) lining/neointimal development and the thromboresistance of electrostatically EC seeded small diameter ChronoFlex-polyurethane vascular grafts. The evaluation consisted of harvesting autologous, canine jugular vein ECs, electrostatically seeding the polyurethane grafts (4-mm I.D., length = 6 cm) with the harvested ECs, implanting the grafts in a canine femoral artery model for four to six weeks, and excising the grafts for histological and scanning electron microscopy evaluations. Results of the histological evaluation (mid-graft region only) indicated that electrostatic EC seeding led to neointimal development and to minimal to no thrombus formation within the EC seeded grafts. The unseeded control grafts resulted in no neointimal development and substantial thrombus formation on the graft luminal surfaces. Scanning electron microscopy examination demonstrated a mature, confluent endothelium with a "cobblestone" appearance on the EC seeded graft luminal surface after six weeks. We conclude that electrostatic EC seeding enhanced the development of a neointima and reduced the incidence of thrombosis in polyurethane grafts implanted in a canine femoral artery model. PMID:12222757

  8. Synovial biopsy

    MedlinePlus

    ... small incision. After anesthesia, an instrument called a trocar is inserted into the joint space. This tool ... area. A biopsy grasper is inserted through the trocar and turned to cut out a tissue segment. ...

  9. 23. NORTHEAST TO CIRCA 1875 POWER SHEAR, PUNCH, AND RIVETING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    23. NORTHEAST TO CIRCA 1875 POWER SHEAR, PUNCH, AND RIVETING MACHINE SET UP TO DEMONSTRATE USE IN RIVETING COMPONENTS OF WHEEL ARMS FOR ELI WINDMILLS. HISTORIC DEBRIS FROM PUNCHING WORK IS VISIBLE BENEATH THE MACHINE IN THE OPERATOR'S PIT.' ON THE LEFT IS A U-SHAPED LOVEJOY FIELD PUNCH FOR USE IN INSTALLING STEEL WINDMILL/TOWER COMPONENTS. - Kregel Windmill Company Factory, 1416 Central Avenue, Nebraska City, Otoe County, NE

  10. Lymph node biopsy

    MedlinePlus

    Biopsy - lymph nodes; Open lymph node biopsy; Fine needle aspiration biopsy; Sentinel lymph node biopsy ... then sent to the laboratory for examination. A needle biopsy involves inserting a needle into a lymph ...

  11. Testicular biopsy

    MedlinePlus

    ... egg in the lab. This process is called in vitro fertilization. Testicular biopsy may also be done if you have found a lump during testicular self-examination . If tests ... the lump may be in the testicle, surgery may be needed to look ...

  12. Deformation field heterogeneity in punch indentation

    PubMed Central

    Murthy, Tejas G.; Saldana, Christopher; Hudspeth, Matthew; M'Saoubi, Rachid

    2014-01-01

    Plastic heterogeneity in indentation is fundamental for understanding mechanics of hardness testing and impression-based deformation processing methods. The heterogeneous deformation underlying plane-strain indentation was investigated in plastic loading of copper by a flat punch. Deformation parameters were measured, in situ, by tracking the motion of asperities in high-speed optical imaging. These measurements were coupled with multi-scale analyses of strength, microstructure and crystallographic texture in the vicinity of the indentation. Self-consistency is demonstrated in description of the deformation field using the in situ mechanics-based measurements and post-mortem materials characterization. Salient features of the punch indentation process elucidated include, among others, the presence of a dead-metal zone underneath the indenter, regions of intense strain rate (e.g. slip lines) and extent of the plastic flow field. Perhaps more intriguing are the transitions between shear-type and compression-type deformation modes over the indentation region that were quantified by the high-resolution crystallographic texture measurements. The evolution of the field concomitant to the progress of indentation is discussed and primary differences between the mechanics of indentation for a rigid perfectly plastic material and a strain-hardening material are described. PMID:24910521

  13. Tester automatically checks paper tape punch and reader after maintenance

    NASA Technical Reports Server (NTRS)

    Mazer, L.; Mc Murchy, D. D.

    1967-01-01

    Device automatically bench tests paper tape punches and readers in a simulated operating environment following routine maintenance. The reader and punch operate back-to-back and the paper tape output feeds the reader. The tape leader is prepunched with an arbitrary pattern that is continuously reproduced during the check.

  14. Die and telescoping punch form convolutions in thin diaphragm

    NASA Technical Reports Server (NTRS)

    1965-01-01

    Die and punch set forms convolutions in thin dished metal diaphragm without stretching the metal too thin at sharp curvatures. The die corresponds to the metal shape to be formed, and the punch consists of elements that progressively slide against one another under the restraint of a compressed-air cushion to mate with the die.

  15. Measuring the force of punches and kicks among combat sport athletes using a modified punching bag with an embedded accelerometer.

    PubMed

    Buśko, Krzysztof; Staniak, Zbigniew; Szark-Eckardt, Mirosława; Nikolaidis, Pantelis Theodoros; Mazur-Różycka, Joanna; Łach, Patrycja; Michalski, Radosław; Gajewski, Jan; Górski, Michał

    2016-01-01

    The main aim of the study was to design a new system to measure punching and kicking forces as well as reaction times in combat sport athletes. In addition, the study examined whether there were any intergender differences in the force of punches thrown by boxers and kicking forces delivered by taekwondo athletes. Boxers (male, n = 13; female, n = 7) were examined for the force of single straight punches and taekwondo athletes (male, n = 14; female, n = 14) for force of single Apdolio and Dwit Chagi kicks. The punching bag was equipped with acceleration transducers and gyroscopes embedded in a cylinder covered with a layer to absorb shock as well as a set of colour signal diodes. Value of the punching bag's acceleration was used for calculating: strike force; the punching location on the bag; and time of a strike. The relative error of force calculation was 3%; the relative error in acceleration measurement was less than 1%. The force of a straight rear-hand punch was greater than the force of a lead-hand punch among male and female boxers. The force of Apdolio kick delivered with a rear leg was greater compared to a lead leg among female and male taekwondo athletes. Significant gender differences were noticed in the force in both types of kicks. In boxers, intergender differences were reported only for the force of a punch thrown with the rear hand. Based on these findings, it was concluded that the modified punching bag is a good diagnostic tool for combat sports.

  16. Nasal mucosal biopsy

    MedlinePlus

    Biopsy - nasal mucosa; Nose biopsy ... to fast for a few hours before the biopsy. ... Nasal mucosal biopsy is usually done when abnormal tissue is seen during examination of the nose. It may also be done ...

  17. Biopsy - biliary tract

    MedlinePlus

    Cytology analysis - biliary tract; Biliary tract biopsy ... A sample for a biliary tract biopsy can be obtained in different ways. A needle biopsy can be done if you have a well-defined tumor. The biopsy site ...

  18. Fabrication of tungsten micro-punch for micro-nozzles

    NASA Astrophysics Data System (ADS)

    Lim, Hyung-Jun; Lim, Young-Mo; Kim, Soo Hyun

    2001-08-01

    A very thin electrode with a tapered shape and a cylindrical tip, named ultrathin punch, is fabricated by electrochemical etching and by controlling the vertical position of the electrode during etching. We used electrochemical etching by which we obtain punches quickly and simply. The fabrication procedure and its results are presented in this article. With this punch, we can get holes or nozzles for ink-jet printers, textile machines, and other uses. Various angles of the taper can be obtained by adjusting the immersion depth. The tip diameter also can be controlled by adjusting current density and etching time.

  19. Star Catalogs on Punched Cards and Magnetic Tape

    NASA Technical Reports Server (NTRS)

    Berbert, J. H.

    1961-01-01

    In connection with the calibration of the Minitrack satellite tracking stations, the Goddard Space Flight Center has had the contents of a number of star catalogs put on punched cards and magnetic tape. This report discusses the plate data reduction procedures, briefly describes the information on the punched cards and magnetic tape, and calls attention to other applications of the card and tape star catalogs. The Goddard Space Flight Center has offered to prepare duplicate catalogs for qualified organizations.

  20. An Ultrathin Endoscope with a 2.4-mm Working Channel Shortens the Esophagogastroduodenoscopy Time by Shortening the Suction Time

    PubMed Central

    Shinozaki, Satoshi; Miura, Yoshimasa; Ino, Yuji; Shinozaki, Kenjiro; Lefor, Alan Kawarai; Yamamoto, Hironori

    2015-01-01

    Background/Aims: Poor suction ability through a narrow working channel prolongs esophagogastroduodenoscopy (EGD). The aim of this study was to evaluate suction with a new ultrathin endoscope (EG-580NW2; Fujifilm Corp.) having a 2.4-mm working channel in clinical practice. Methods: To evaluate in vitro suction, 200 mL water was suctioned and the suction time was measured. The clinical data of 117 patients who underwent EGD were retrospectively reviewed on the basis of recorded video, and the suction time was measured by using a stopwatch. Results: In vitro, the suction time with the EG-580NW2 endoscope was significantly shorter than that with the use of an ultrathin endoscope with a 2.0-mm working channel (EG-580NW; mean ± standard deviation, 22.7±1.1 seconds vs. 34.7±2.2 seconds; p<0.001). We analyzed the total time and the suction time for routine EGD in 117 patients (50 in the EG-580NW2 group and 67 in the EG-580NW group). In the EG-580NW2 group, the total time for EGD was significantly shorter than that in the EG-580NW group (275.3±42.0 seconds vs. 300.6±46.5 seconds, p=0.003). In the EG-580NW2 group, the suction time was significantly shorter than that in the EG-580NW group (19.2±7.6 seconds vs. 38.0±15.9 seconds, p<0.001). Conclusions: An ultrathin endoscope with a 2.4-mm working channel considerably shortens the routine EGD time by shortening the suction time, in comparison with an endoscope with a 2.0-mm working channel. PMID:26668798

  1. Isolation of high quality protein samples from punches of formalin fixed and paraffin embedded tissue blocks.

    PubMed

    Kroll, J; Becker, K F; Kuphal, S; Hein, R; Hofstädter, F; Bosserhoff, A K

    2008-04-01

    In general, it is believed that the extraction of proteins from formalin-fixed paraffin embedded samples is not feasible. However, recently a new technique was developed, presenting the extraction of non-degraded, full length proteins from formalin fixed tissues, usable for western blotting and protein arrays. In the study presented here, we applied this technique to punch biopsies of formalin fixed tissues embedded in paraffin to reduce heterogeneity of the tissue represented in sections, and to ensure analysing mainly defined cellular material. Successful extraction was achieved even from very small samples (0.7 mm(3)). Additionally, we were able to detect highly glycosylated proteins and protein modification, such as phosphorylation. Interestingly, with this technique it is feasible to extract high quality proteins from 14 year old samples. In summary, the new technique makes a great pool of material now usable for molecular analysis with high throughput tools. PMID:18228195

  2. Accuracy validation for MRI-guided robotic prostate biopsy

    NASA Astrophysics Data System (ADS)

    Xu, Helen; Lasso, Andras; Vikal, Siddharth; Guion, Peter; Krieger, Axel; Kaushal, Aradhana; Whitcomb, Louis L.; Fichtinger, Gabor

    2010-02-01

    We report a quantitative evaluation of the clinical accuracy of a MRI-guided robotic prostate biopsy system that has been in use for over five years at the U.S. National Cancer Institute. A two-step rigid volume registration using mutual information between the pre and post needle insertion images was performed. Contour overlays of the prostate before and after registration were used to validate the registration. A total of 20 biopsies from 5 patients were evaluated. The maximum registration error was 2 mm. The mean biopsy target displacement, needle placement error, and biopsy error was 5.4 mm, 2.2 mm, and 5.1 mm respectively. The results show that the pre-planned biopsy target did dislocate during the procedure and therefore causing biopsy errors.

  3. Open lung biopsy

    MedlinePlus

    Biopsy - open lung ... An open lung biopsy is done in the hospital using general anesthesia , which means you are asleep and pain- ... The open lung biopsy is done to evaluate lung problems seen on x-ray or CT scan .

  4. Bone biopsy (image)

    MedlinePlus

    A bone biopsy is performed by making a small incision into the skin. A biopsy needle retrieves a sample of bone and it ... examination. The most common reasons for bone lesion biopsy are to distinguish between benign and malignant bone ...

  5. Muscle biopsy (image)

    MedlinePlus

    A muscle biopsy involves removal of a plug of tissue usually by a needle to be later used for examination. Sometimes ... there is a patchy condition expected an open biopsy may be used. Open biopsy involves a small ...

  6. North Massif lithologies and chemical compositions viewed from 2-4 mm particles of soil sample 76503

    NASA Technical Reports Server (NTRS)

    Bishop, Kaylynn M.; Jolliff, Bradley L.; Korotev, Randy L.; Haskin, Larry A.

    1992-01-01

    We identify the lithologic and compositional components of soil 76503 based on INAA of 243 2-4-mm particles and 72 thin sections from these and associated 1-2-mm particles (76502). We present a statistical distribution of the major compositional types as the first step of a detailed comparative study of the North and South Massifs. The soil sample was collected well away from any boulder and is more representative of typical North Massif material than any single large rock or boulder sample. So far, our examination of the 76503 particles has provided a better definition of precursor igneous lithologies and their petrogenetic relationships. It has enabled us to refine the nature of mixing components for the North Massif less than 1-mm fines. It has confirmed the differences in lithologies and their proportions between materials of the North and South Massifs; e.g., the North Massif is distinguished by the absence of a 72275-type KREEP component, the abundance of a highly magnesian igneous component, and the absence of certain types of melt compositions found in the South Massif samples.

  7. Punch-through characteristics of FOXFET biased detectors

    NASA Astrophysics Data System (ADS)

    Bacchetta, N.; Bisello, D.; da Ros, R.; Giraldo, A.; Gotra, Yu; Paccagnella, A.; Verzellesi, G.

    1994-08-01

    The main punch-through characteristics have been studied on Field OXide FETs (FOXFETs) used for microstrip biasing in Si detectors. The voltage-current DC curves have been studied on devices with different channel width/length ratios, fabricated on Si substrates with different doping levels. The punch-through threshold voltage depends on the positive charge in the gate oxide, device layout and temperature. The relation between punch-through current and dynamic resistance is insensitive to charge accumulation in the gate oxide induced by irradiation and to different Si donor doping levels. Dynamic resistance however varies as the doping changes from n- to p-type, and it also depends on the Si bulk damage induced by neutron irradiation. The AC impedance will reproduce the DC dynamic resistance, but show also large effects due to parasitic capacitance, which dominates the FOXFET response at high frequency and can affect the detector performance.

  8. Analysis of direct punch velocity in professional defence

    NASA Astrophysics Data System (ADS)

    Lapkova, Dora; Adamek, Milan

    2016-06-01

    This paper is focused on analysis of a direct punch. Nowadays, professional defence is basic part of effective protection of people and property. There are many striking techniques and the goal of this research was to analyze the direct punch. The analysis is aimed to measure the velocity with help of high speed camera Olympus i-Speed 2 and then find the dependences of this velocity on input parameters. For data analysis two pieces of software were used - i-Speed Control Software and MINITAB. 111 participants took part in this experiment. The results are presented in this paper - especially dependence of mean velocity on time and difference in velocity between genders.

  9. Effect of laser incidence angle on cut quality of 4 mm thick stainless steel sheet using fiber laser

    NASA Astrophysics Data System (ADS)

    Mullick, Suvradip; Agrawal, Arpit Kumar; Nath, Ashish Kumar

    2016-07-01

    Fiber laser has potential to outperform the more traditionally used CO2 lasers in sheet metal cutting applications due to its higher efficiency, better beam quality, reliability and ease of beam delivery through optical fiber. It has been however, reported that the higher focusability and shorter wavelength are advantageous for cutting thin metal sheets up to about 2 mm only. Better focasability results in narrower kerf-width, which leads to an earlier flow separation in the flow of assist gas within the kerf, resulting in uncontrolled material removal and poor cut quality. However, the advarse effect of tight focusability can be taken care by shifting the focal point position towards the bottom surface of work-piece, which results in a wider kerf size. This results in a more stable flow within the kerf for a longer depth, which improves the cut quality. It has also been reported that fiber laser has an unfavourable angle of incidence during cutting of thick sections, resulting in poor absorption at the metal surface. Therefore, the effect of laser incidence angle, along with other process parameters, viz. cutting speed and assist gas pressure on the cut quality of 4 mm thick steel sheet has been investigated. The change in laser incidence angle has been incorporated by inclining the beam towards and away from the cut front, and the quality factors are taken as the ratio of kerf width and the striation depth. Besides the absorption of laser radiation, beam inclination is also expected to influence the gas flow characteristics inside the kerf, shear force phenomena on the molten pool, laser beam coupling and laser power distribution at the inclined cut surface. Design of experiment has been used by implementing response surface methodology (RSM) to study the parametric dependence of cut quality, as well as to find out the optimum cut quality. An improvement in quality has been observed for both the inclination due to the combined effect of multiple phenomena.

  10. An in vivo comparison of radiofrequency cardiac lesions formed by standard and magnetically steered 4 mm tip catheters

    PubMed Central

    Thornton, A.S.; De Castro, C.A. Brito; van Deel, E.; van Beusekom, H.M.M.; Jordaens, L.

    2010-01-01

    Background. In vivo comparison of cardiac radiofrequency ablation lesions between standard and magnetically steered 4 mm tip catheters has never been reported. Methods. High and low right atrium (RA) free wall, isthmus, right ventricle (RV) free wall and outflow tract lesions were studied macroscopically and microscopically five days after lesion formation in seven pigs. Shape, size, thrombus formation, and ablation parameters were compared. The effect of minimal, medium and high wall contact was assessed by a contact measurement utility for magnetic catheters. Results. All 14 RA free wall lesions were transmural with a similar epicardial and endocardial surface area. In the RV, the epicardial area usually appeared to be smaller than the endocardial area with standard catheters. Isthmus lesions were difficult to assess transmurality. There was no difference in endocardial area: standard 39 mm2 (range 16 to 82 mm2) vs. magnetic 36 mm2 (range 23 to 111 mm2). If the catheter tip was perpendicular to the tissue, magnetic lesions were more often round or oval, while standard lesions were more often elongated (p<0.05). When the catheter tip was parallel to tissue, lesions always tended to be elongated. Microscopic characteristics were similar. The contact utility was not useful. Average impedance (p<0.0001) and energy delivered (p<0.05) were less with magnetic catheters. Conclusion. Lesions from magnetically steered catheters are transmural of similar size, but with less variability than standard catheter lesions when the tip is perpendicular to the tissue. Magnetic lesions are associated with lower impedance and energy delivery. This suggests a more stable tip-to-tissue contact. (Neth Heart J 2010;18:66–71.) PMID:20200611

  11. A 4mm spectroscopic dual-beam receiver for the Robert C. Byrd green bank radio telescope

    NASA Astrophysics Data System (ADS)

    White, Steven; Frayer, David; Stennes, Mike; Simon, Robert; Watts, Galen; Norrod, Roger; Bryerton, Eric; Srikanth, Sivasankaran; Pospieszalski, Marian

    2012-09-01

    With a 100-meter aperture, and recent improvements to its surface accuracy and servo system upgrades, the Robert C. Byrd Green Bank Telescope is the most sensitive telescope operating at 90 GHz. A dual-feed heterodyne receiver is developed for observations at the lower frequency end of the 3-4mm atmospheric window (67 to 93 GHz). The science goals are primarily molecular spectroscopic studies of star formation and astrochemistry both internal and external to the Milky Way galaxy. Studies of the structural and physical properties of star-forming, cold-cloud cores will be revolutionized with molecular spectroscopy of the deuterium and other important species within the band. Essential for spectroscopy is the ability to remove slow gain and atmospheric variations. An optical table external to the cooled components rotates into the path of either beam an ambient temperature load, an offset mirror for viewing an internal cold load, or a quarter-wave plate that produces circular polarization for VLBI observations. A composite waveguide window comprised of HDPE, Zitex, and z-cut quartz provides a high-strength, low-loss medium for transmission of the signal to the cooled corrugated feed horn. An orthomode transducer separates the polarization components which are amplified by low noise HEMT amplifiers. Warm W-band MMIC amplifiers are required to compensate a negative gain slope and to reduce noise contributions from the down conversion to the GBT IF frequencies. Initial science results and receiver performance during commissioning observations will be presented along with details of the component design.

  12. Skin biopsy: Biopsy issues in specific diseases.

    PubMed

    Elston, Dirk M; Stratman, Erik J; Miller, Stanley J

    2016-01-01

    Misdiagnosis may result from biopsy site selection, technique, or choice of transport media. Important potential sources of error include false-negative direct immunofluorescence results based on poor site selection, uninformative biopsy specimens based on both site selection and technique, and spurious interpretations of pigmented lesions and nonmelanoma skin cancer based on biopsy technique. Part I of this 2-part continuing medical education article addresses common pitfalls involving site selection and biopsy technique in the diagnosis of bullous diseases, vasculitis, panniculitis, connective tissue diseases, drug eruptions, graft-versus-host disease, staphylococcal scalded skin syndrome, hair disorders, and neoplastic disorders. Understanding these potential pitfalls can result in improved diagnostic yield and patient outcomes.

  13. Smooth muscle pseudotumours: a potentially confusing artefact of rectal biopsy.

    PubMed Central

    Dankwa, E K; Davies, J D

    1988-01-01

    An artefactual smooth muscle lesion was found in seven of 500 consecutive rectal biopsy specimens. The lesions had the deceptive appearance of a genuine tumour although none of the patients with the lesion had presented with a rectal mucosal swelling. The morphology of the lesion and its poor reproducibility under experimental conditions suggested that it was an artefact of the biopsy procedure: it was easily reproduced in resected specimens of large bowel using punch or basket forceps but not when using flat forceps. The presence of the lesion seems to depend on the type of forceps used rather than on differences in deployment and seems to be caused by avulsion of the superficial part of the muscularis propria and its incorporation into the tissues included in rectal biopsy specimens. Images Fig 2 Fig 3 Fig 1 Fig 4 PMID:3045159

  14. Neuropathological alterations in diabetic truncal neuropathy: evaluation by skin biopsy

    PubMed Central

    Lauria, G.; McArthur, J.; Hauer, P.; Griffin, J.; Cornblath, D.

    1998-01-01

    OBJECTIVES—To describe the neuropathological features in skin biopsies from patients with diabetic truncal neuropathy.
METHODS—Three patients with diabetic truncal neuropathy underwent skin biopsies from both symptomatic and asymptomatic regions of the chest and trunk. After local anaesthesia, biopsies were performed using a 3 mm diameter punch device (Acupunch). Intraepidermal nerve fibres (IENFs), the most distal processes of small myelinated and unmyelinated nerve fibres, were identified after staining with PGP 9.5 as previously described.
RESULTS—Diabetes was diagnosed at the time of the neurological presentation in two, and one was a known diabetic patient. All three had associated sensory-motor polyneuropathy. In all, skin biopsies showed a marked reduction of both epidermal and dermal nerve fibres in the symptomatic dermatomes, compared with skin from asymptomatic truncal areas. In one patient, a follow up skin biopsy when symptoms had improved showed a return of IENFs.
CONCLUSIONS—In diabetic truncal neuropathy, skin biopsies from symptomatic regions show a loss of IENFs. After clinical recovery, there is a return of the IENF population, suggesting that improvement occurs by nerve regeneration. These findings suggest that sensory nerve fibre injury in diabetic truncal neuropathy is distal to or within the sensory ganglia. Skin biopsy provides a possible tool for understanding the pathophysiology of the disease.

 PMID:9810952

  15. Punch from a patient led to correct diagnosis.

    PubMed

    Hall, Charlotte Lara

    2016-08-24

    During a recent placement on an older people's ward, I was punched in the face by a patient. It was during visiting time, and the patient - who I will call Jim - had come out of his room and was trying to enter another patient's room. PMID:27641587

  16. Configurational phases in elastic foams under lengthscale-free punching

    NASA Astrophysics Data System (ADS)

    Sabuwala, Tapan; Dai, Xiangyu; Gioia, Gustavo

    2016-08-01

    We carry out experiments with brick-like specimens of elastic open-cell (EOC) foams of three relative densities. Individual specimens may be "tall" (height = width = depth) or "short" (2 height = width = depth). We place each specimen on a supporting plate and use a lengthscale-free (wedge-shaped or conical) punch to apply forces downward along the specimen's height. Regardless of the type of specimen, the force-penetration curves remain linear, for the wedge-shaped punch, or quadratic, for the conical punch, up to a sizable penetration commensurate with the smallest lengthscale of the specimen. After that there is an abrupt, all-but-discontinuous change in stiffness: if the specimen is tall, the stiffness drops; if the specimen is short, the stiffness shoots up. To analyze these curious experimental results, we posit that EOC foams can be found in either of two configurational phases, here termed the low-strain phase and the high-strain phase, which share a two-dimensional interface (a surface of strain discontinuity). The analysis may be outlined as follows. In the first part of an experiment, there obtains a "similarity regime" in which the penetration of the punch and the radius of the interface are the only prevailing lengthscales (because the punch is lengthscale free). In this case, it is possible to show that the force-penetration curve must be linear, or quadratic, depending on whether the punch be wedge-shaped or conical, respectively. This prediction of the analysis is consistent with the experiments. In time, the similarity regime breaks down when the interface reaches one of the specimen's boundaries distal to the tip of the punch. If the specimen is tall, the soft, stress-free lateral boundary is reached first, and the stiffness must drop; if the specimen is short, the hard boundary in contact with the supporting plate is reached first, and the stiffness must shoot up. These predictions too are consistent with the experiments. To provide direct

  17. Optimization of prostate biopsy

    NASA Astrophysics Data System (ADS)

    Bauer, John J.; Zeng, Jianchao; Weir, James; Zhang, Wei; Sesterhenn, Isabell A.; Connelly, Roger R.; Moul, Judd W.; Mun, Seong K.

    1999-05-01

    Urologists routinely use the systematic sextant needle biopsy technique to detect prostate cancer. However, recent evidence suggests that this technique has a significant sampling error. We have developed a novel 3D computer assisted prostate biopsy simulator based upon 201 whole- mounted step-sectioned radical prostatectomy specimens to compare the diagnostic accuracy of various prostate needle biopsy protocols. Computerized prostate models have been developed to accurately depict the anatomy of the prostate and all individual tumor foci. We obtained 18-biopsies of each prostate model to determine the detection rates of various biopsy protocols. As a result, the 10- and 12- pattern biopsy protocols had a 99.0 percent detection rate, while the traditional sextant biopsy protocol rate was only 72.6 percent. The 5-region biopsy protocol had a 90.5 percent detection rate. the lateral sextant pattern revealed a detection rate of 95.5 percent, whereas the 4-pattern lateral biopsy protocol had a 93.5 percent detection rate. Our results suggest that all the biopsy protocols that use laterally placed biopsies based upon the five region anatomical model are superior to the routinely used sextant prostate biopsy pattern. Lateral biopsies in the mid and apical zones of the gland are the most important.

  18. Cold knife cone biopsy

    MedlinePlus

    ... this page: //medlineplus.gov/ency/article/003910.htm Cold knife cone biopsy To use the sharing features on this page, please enable JavaScript. A cold knife cone biopsy (conization) is surgery to remove ...

  19. Nerve biopsy (image)

    MedlinePlus

    Nerve biopsy is the removal of a small piece of nerve for examination. Through a small incision, a sample ... is removed and examined under a microscope. Nerve biopsy may be performed to identify nerve degeneration, identify ...

  20. Percutaneous liver biopsy.

    PubMed

    Rustagi, Tarun; Newton, Eric; Kar, Premashish

    2010-01-01

    Percutaneous liver biopsy has been performed for more than 120 years, and remains an important diagnostic procedure for the management of hepatobiliary disorders. Modern biochemical, immunologic, and radiographic techniques have facilitated the diagnosis and management of liver diseases but have not made liver biopsy obsolete. This comprehensive review article will discuss the history of development of percutaneous liver biopsy, its indications, contraindications, complications and the various aspects of the biopsy procedure in detail.

  1. Biomechanics of the head for Olympic boxer punches to the face

    PubMed Central

    Walilko, T; Viano, D; Bir, C

    2005-01-01

    Objective: The biomechanics of the head for punches to the jaw and the risk of head injury from translational and rotational acceleration were studied. Results: Punch force averaged 3427 (standard deviation (SD) 811) N, hand velocity 9.14 (SD 2.06) m/s, and effective punch mass 2.9 (SD 2.0) kg. Punch force was higher for the heavier weight classes, due primarily to a higher effective mass of the punch. Jaw load was 876 (SD 288) N. The peak translational acceleration was 58 (SD 13) g, rotational acceleration was 6343 (SD 1789) rad/s2, and neck shear was 994 (SD 318) N. Conclusions: Olympic boxers deliver straight punches with high impact velocity and energy transfer. The severity of the punch increases with weight class. PMID:16183766

  2. Newly developed surface modification punches treated with alloying techniques reduce sticking during the manufacture of ibuprofen tablets.

    PubMed

    Uchimoto, Takeaki; Iwao, Yasunori; Yamamoto, Tatsuya; Sawaguchi, Kazuo; Moriuchi, Toshiaki; Noguchi, Shuji; Itai, Shigeru

    2013-01-30

    Sticking is a serious problem during the manufacturing process of tablets. In order to prevent this, we used alloying techniques to prepare metal hardening (MH) and electron beam processing infinite product (EIP) punches with rougher asperity of surfaces than a hard chrome plated (HCr) punch. This study evaluated the anti-sticking properties of the MH and EIP punches compared to the HCr punch, using quantitative scraper force measurements and visual observation, for the manufacture of ibuprofen (Ibu) tablets. The anti-sticking property mechanism of the MH and EIP punches was also confirmed. The amount of Ibu adhering to the punch surface was 66% lower for the MH and EIP punches than for the HCr punch, suggesting a superior anti-sticking property of the MH and EIP punches. The scraper force of the HCr punch was 2.60-4.28 N, while that for the MH and EIP punches was 0.54-1.64 N and 0.42-1.33 N, respectively. The result of X-ray photoelectron spectroscopy suggested that the anti-sticking property of the EIP punch was attributed by the rough asperity as well as existence of low friction substance carbon fluoride on the punch surface. In conclusion, this study provides new evidence for the mechanisms behind the superior anti-sticking property of the MH and EIP punches.

  3. A New Sheet Metal Forming System Based on Incremental Punching

    NASA Astrophysics Data System (ADS)

    Luo, Yuanxin

    Stamping is one of the most commonly used manufacturing processes. Everyday, millions of parts are formed by this process. The conventional stamping is to form a part in one or several operations with a press machine and a set/sets of dies. It is very efficient but is not cost effective for small batch production parts and prototypes as the dies are expensive and time consuming to make. Recently, with the increasing demands for low-volume and customer-made products, a die-less forming method, Incremental Sheet Metal Forming (ISMF), has become one of the leading R&D topics in the industry. ISMF uses a small generic tool to apply a sequence of operations along the given path to deform the sheet incrementally. These small deformations accumulate to form the final shape of the part. As a result, different parts can be made by the same setup. Despite of some 30 years of research and development, however, ISMF technology is still premature for industrial applications due to the following reasons: The accuracy of the part is limited; the surface roughness is poor; and the productivity is low. This motivates the presented research. In this research, a new incremental forming system based on incremental punching is designed and built. The system consists of a 3-axes CNC platform, a high speed hydraulic cylinder with a hemispherical forming tool, and a PC-based CNC control system. The hydraulic system provides the forming force to deform the sheet metal with constant stokes, while the CNC system positions the part. When forming a part, the forming tool punches the sheet metal along the given contour of the part punch by punch; when one layer of the part is completed, the forming tool moves down to the next layer; and the process is finished till all layers are completed. The CNC control system works with standard NC code, and hence, is easy to use. In order to ensure the desirable performance of the machine, dynamic analysis of the machine is necessary. The analysis is

  4. EVOLUTION AND EVALUATION OF AUTOLOGOUS MINI PUNCH GRAFTING IN VITILIGO

    PubMed Central

    Lahiri, Koushik

    2009-01-01

    Vitiligo is a result of disrupted epidermal melanization with an undecided etiology and incompletely understood pathogenesis. Various treatment options have resulted in various degrees of success. Various surgical modalities and transplantation techniques have evolved during the last few decades. Of them, miniature punch grafting (PG) has established its place as the easiest, fastest, and least expensive method. Various aspects of this particular procedure have been discussed here. The historical perspective, the instruments, evolution of mini grafting down the ages, and the methodology, advantages, and disadvantages have been discussed. A detailed discussion on the topic along with a review of relevant literature has been provided in this article. PMID:20101312

  5. Punch valve development testing: Low and high velocity test results

    SciTech Connect

    Replogle, W.C.; Brandon, S.L.

    1996-09-01

    This is a report on the use of quasi-static tests to predict fundamental parameters for punch valve development. This report summarizes the results from low and high velocity tests performed with 0.63 and 0.38 cm diameter plungers, 5 cm long penetrating aluminium and composite targets. The low velocity tests, 0.025 m/s, were performed to understand the effects and interactions of plunger diameter plunger tip shape, target material, and target support on penetration energy and plunger functionality. High velocity tests, 75 m/s, were compared to low velocity results.

  6. Bone marrow biopsy

    MedlinePlus

    Biopsy - bone marrow ... A bone marrow biopsy may be done in the health care provider's office or in a hospital. The sample may ... This captures a tiny sample, or core, of bone marrow within the needle. The sample and needle are ...

  7. Simulators of Squamous Cell Carcinoma of the Skin: Diagnostic Challenges on Small Biopsies and Clinicopathological Correlation

    PubMed Central

    Tan, Kong-Bing; Tan, Sze-Hwa; Aw, Derrick Chen-Wee; Jaffar, Huma; Lim, Thiam-Chye; Lee, Shu-Jin; Lee, Yoke-Sun

    2013-01-01

    Squamous cell carcinoma (SCC) is a common and important primary cutaneous malignancy. On skin biopsies, SCC is characterized by significant squamous cell atypia, abnormal keratinization, and invasive features. Diagnostic challenges may occasionally arise, especially in the setting of small punch biopsies or superficial shave biopsies, where only part of the lesion may be assessable by the pathologist. Benign mimics of SCC include pseudoepitheliomatous hyperplasia, eccrine squamous syringometaplasia, inverted follicular keratosis, and keratoacanthoma, while malignant mimics of SCC include basal cell carcinoma, melanoma, and metastatic carcinoma. The careful application of time-honored diagnostic criteria, close clinicopathological correlation and a selective request for a further, deeper, or wider biopsy remain the most useful strategies to clinch the correct diagnosis. This review aims to present the key differential diagnoses of SCC, to discuss common diagnostic pitfalls, and to recommend ways to deal with diagnostically challenging cases. PMID:23878739

  8. Aircraft-Induced Hole Punch and Canal Clouds

    NASA Astrophysics Data System (ADS)

    Heymsfield, A. J.; Kennedy, P.; Massie, S. T.; Schmitt, C. G.; Wang, Z.; Haimov, S.; Rangno, A.

    2009-12-01

    The production of holes and channels in altocumulus clouds by two commercial turboprop aircraft is documented for the first time. An unprecedented data set combining in situ measurements from microphysical probes with remote sensing measurements from cloud radar and lidar, all operating from the NSF/NCAR C130 aircraft, as well as ground-based NOAA and CSU radars, is used to describe the radar/lidar properties of a hole punch cloud and channel and the ensuing ice microphysical properties and structure of the ice column that subsequently developed. Ice particle production by commercial turboprop aircraft climbing through clouds much warmer than the regions where contrails are produced has the potential to modify significantly the cloud microphysical properties and effectively seed them under some conditions. Jet aircraft may also be producing hole punch clouds when flying through altocumulus with supercooled droplets at heights lower than their normal cruise altitudes where contrails can form. Commercial aircraft therefore can generate ice and affect the clouds at temperatures as much as 30°C warmer than the -40°C contrail formation threshold temperature.

  9. Hamate body and capitate fracture in punch injury.

    PubMed

    Goliver, Jacob A; Adamow, Joshua S; Goliver, Jake

    2014-10-01

    Hamate fractures represent only 2% to 4% of all carpal bone fractures because they require a large degree of force to the hand or wrist. This is a case report of a patient with hamate and capitate fractures after a punch injury. It details the minute change seen in routine 3-view radiographic imagery and indications for computed tomography. A 29-year-old African American man with professional boxing training presented to the emergency department with pain and swelling in the hand and wrist after striking a refrigerator with his right hand. Enough force generated along the axial plane of the fourth and fifth metacarpals either from punching or from falling with a clenched fist is capable of fracturing both the hamate and capitate bones. Three-view radiographs may not visualize the fracture, so computed tomography should be ordered to better visualize any pathology. The risks to not detecting a hamate body fracture are nonunion of the bone, posttraumatic arthritis, decreased grip strength, and decreased range of motion of the hand. Because of rarity, there is no criterion standard therapy, but the general approach is open reduction and internal fixation using Kirschner wires and wrist immobilization for a minimum of 8 weeks. A high degree of clinical suspicion on examination is required for the proper approach to confirm a hamate fracture. PMID:24792935

  10. Salivary gland biopsy

    MedlinePlus

    Biopsy - salivary gland ... You have several pairs of salivary glands that drain into your mouth: A major pair in front of the ears (parotid glands) Another major pair beneath your jaw (submandibular ...

  11. Colposcopy - directed biopsy

    MedlinePlus

    ... squamous cells - colposcopy; Pap smear - colposcopy; HPV - colposcopy; Human papilloma virus - colposcopy; Cervix - colposcopy; Colposcopy ... also called cervical dysplasia) Cervical warts (infection with human papilloma virus , or HPV) If the biopsy does not determine ...

  12. Mediastinoscopy with biopsy

    MedlinePlus

    ... procedure is also done for certain infections (tuberculosis, sarcoidosis) and autoimmune disorders . Normal Results Biopsies of lymph ... findings may indicate: Hodgkin disease Lung cancer Lymphoma Sarcoidosis The spread of disease from one body part ...

  13. Biopsy catheter (image)

    MedlinePlus

    ... examination, a heart biopsy can be performed. A catheter is carefully threaded into an artery or vein to gain access into the heart. A bioptome (catheter with jaws in its tip) is then introduced. ...

  14. β-alanine improves punch force and frequency in amateur boxers during a simulated contest.

    PubMed

    Donovan, Tim; Ballam, Tim; Morton, James P; Close, Graeme L

    2012-10-01

    The aim of this study was to test the hypothesis that ß-alanine supplementation improves punch power and frequency in amateur boxers during a simulated contest. Sixteen amateur boxers (each approximately 6 yr experience) were assigned to ß-alanine (n = 8; 1.5 g 4 times/d for 4 wk) or placebo supplementation (n = 8) after initially being assessed for baseline punch performance. Before and after the supplementation period, all boxers completed a simulated contest consisting of 3 × 3-min rounds (interspersed with 60-s rests) on a punching bag (with a force transducer attached). Each round involved performing 2 min 50 s standardized punching (standardized jab, cross combination) based on notation analysis, whereas the last 10 s involved maximal-output punching (standardized jab, cross combination), during which time punch force and frequency were recorded. Postcontest blood lactate was significantly increased in the ß-alanine group (presupplementation 9.5 ± 0.9 mmol/L, postsupplementation 12.6 ± 0.5 mmol/L, p < .05), whereas the placebo group showed no change (presupplementation 8 ± 2.8 mmol/L, postsupplementation 7.0 ± 2.7 mmol/L; p > .05). During the 10-s maximal-output punching, changes in mean punch force (ß-alanine 20 ± 1.01 kg, placebo 1 ± 1 kg) and punch frequency (ß-alanine 5 ± 4, placebo -2 ± 3) were greater (p < .05) in the ß-alanine-supplemented group. The authors conclude that ß-alanine supplementation improves punching performance in amateur boxers and suggest that this supplementation protocol may also prove ergogenic for other combat-related sports.

  15. 29 CFR 570.59 - Occupations involved in the operation of power-driven metal forming, punching, and shearing...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... forming, punching, and shearing machines (Order 8). 570.59 Section 570.59 Labor Regulations Relating to... in the operation of power-driven metal forming, punching, and shearing machines (Order 8). (a... following power-driven metal forming, punching, and shearing machines: (i) All rolling machines, such...

  16. 29 CFR 570.59 - Occupations involved in the operation of power-driven metal forming, punching, and shearing...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... forming, punching, and shearing machines (Order 8). 570.59 Section 570.59 Labor Regulations Relating to... in the operation of power-driven metal forming, punching, and shearing machines (Order 8). (a... following power-driven metal forming, punching, and shearing machines: (i) All rolling machines, such...

  17. 29 CFR 570.59 - Occupations involved in the operation of power-driven metal forming, punching, and shearing...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... forming, punching, and shearing machines (Order 8). 570.59 Section 570.59 Labor Regulations Relating to... in the operation of power-driven metal forming, punching, and shearing machines (Order 8). (a... following power-driven metal forming, punching, and shearing machines: (i) All rolling machines, such...

  18. 29 CFR 570.59 - Occupations involved in the operation of power-driven metal forming, punching, and shearing...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... forming, punching, and shearing machines (Order 8). 570.59 Section 570.59 Labor Regulations Relating to... in the operation of power-driven metal forming, punching, and shearing machines (Order 8). (a... following power-driven metal forming, punching, and shearing machines: (i) All rolling machines, such...

  19. Condensation heat transfer characteristics of R410A-oil mixture in 5 mm and 4 mm outside diameter horizontal microfin tubes

    SciTech Connect

    Huang, Xiangchao; Ding, Guoliang; Hu, Haitao; Zhu, Yu.; Gao, Yifeng; Deng, Bin

    2010-10-15

    Condensation heat transfer characteristics of R410A-oil mixture in 5 mm and 4 mm outside diameter horizontal microfin tubes were investigated experimentally. The experimental condensing temperature is 40 C, and nominal oil concentration range is from 0% to 5%. The test results indicate that the presence of oil deteriorates the heat transfer. The deterioration effect is negligible at nominal oil concentration of 1%, and becomes obvious with the increase of nominal oil concentration. At 5% nominal oil concentration, the heat transfer coefficient of R410A-oil mixture is found to have a maximum reduction of 25.1% and 23.8% for 5 mm and 4 mm tubes, respectively. The predictabilities of the existing condensation heat transfer correlations were verified with the experimental data, and Yu and Koyama correlation shows the best predictability. By replacing the pure refrigerant properties with the mixture's properties, Yu and Koyama correlation has a deviation of -15% to + 20% in predicting the local condensation heat transfer coefficient of R410A-oil mixture. (author)

  20. Breast Biopsy System

    NASA Technical Reports Server (NTRS)

    1994-01-01

    Charge Coupled Devices (CCDs) are high technology silicon chips that connect light directly into electronic or digital images, which can be manipulated or enhanced by computers. When Goddard Space Flight Center (GSFC) scientists realized that existing CCD technology could not meet scientific requirements for the Hubble Space Telescope Imagining Spectrograph, GSFC contracted with Scientific Imaging Technologies, Inc. (SITe) to develop an advanced CCD. SITe then applied many of the NASA-driven enhancements to the manufacture of CCDs for digital mammography. The resulting device images breast tissue more clearly and efficiently. The LORAD Stereo Guide Breast Biopsy system incorporates SITe's CCD as part of a digital camera system that is replacing surgical biopsy in many cases. Known as stereotactic needle biopsy, it is performed under local anesthesia with a needle and saves women time, pain, scarring, radiation exposure and money.

  1. John Punch, Scotist Holy War, and the Irish Catholic Revolutionary Tradition in the Seventeenth Century.

    PubMed

    Campbell, Ian W

    2016-07-01

    During the 1640s, the Irish Franciscan theologian John Punch taught his theology students in Rome that war against Protestants was made just by their religion alone. Jesuits like Luis de Molina identified the holy war tradition in which Punch stood as a Scotist one, and insisted that the Scotists had confused the natural and supernatural spheres. Among Irishmen, Punch was unusual. The main Irish Catholic revolutionary tradition employed Jesuit and Thomist theory. They argued that the Stuarts had lost the right to rule Ireland for natural reasons, not supernatural ones; because the Stuarts were tyrants, not because they were Protestants. PMID:27477343

  2. John Punch, Scotist Holy War, and the Irish Catholic Revolutionary Tradition in the Seventeenth Century.

    PubMed

    Campbell, Ian W

    2016-07-01

    During the 1640s, the Irish Franciscan theologian John Punch taught his theology students in Rome that war against Protestants was made just by their religion alone. Jesuits like Luis de Molina identified the holy war tradition in which Punch stood as a Scotist one, and insisted that the Scotists had confused the natural and supernatural spheres. Among Irishmen, Punch was unusual. The main Irish Catholic revolutionary tradition employed Jesuit and Thomist theory. They argued that the Stuarts had lost the right to rule Ireland for natural reasons, not supernatural ones; because the Stuarts were tyrants, not because they were Protestants.

  3. High-throughput sequencing of forensic genetic samples using punches of FTA cards with buccal swabs.

    PubMed

    Kampmann, Marie-Louise; Buchard, Anders; Børsting, Claus; Morling, Niels

    2016-01-01

    Here, we demonstrate that punches from buccal swab samples preserved on FTA cards can be used for high-throughput DNA sequencing, also known as massively parallel sequencing (MPS). We typed 44 reference samples with the HID-Ion AmpliSeq Identity Panel using washed 1.2 mm punches from FTA cards with buccal swabs and compared the results with those obtained with DNA extracted using the EZ1 DNA Investigator Kit. Concordant profiles were obtained for all samples. Our protocol includes simple punch, wash, and PCR steps, reducing cost and hands-on time in the laboratory. Furthermore, it facilitates automation of DNA sequencing. PMID:27625209

  4. Thyroid gland biopsy (image)

    MedlinePlus

    The thyroid is a gland located in the neck. It is a part of the endocrine (hormone) system, and plays a major role in regulating ... sample of cells is needed from the thyroid gland a fine needle biopsy can be performed. During ...

  5. Studies on Deformation Mechanism and Punch Taper Effects on Nanoimprint Processes by Molecular Dynamics

    NASA Astrophysics Data System (ADS)

    Hsu, Quang-Cherng; Wu, Chen-Da; Fang, Te-Hua

    2004-06-01

    A molecular dynamics analysis model is proposed to study the effects of parameters on nanoimprint process, for example: taper angle, imprint depth and spring back. The nanoimprint process comprises one punch and one specimen at an isothermal state of 400K, while the deformed material is a copper FCC single crystal and the punch material is a nickel FCC single crystal. There were a total of 10,080 atoms in copper measuring 12.02 nm × 5.72 nm in length and height, respectively. There were a total of 4,200 atoms in nickel where the typical length and depth in punch tooth are 6.24 nm × 3.52 nm, respectively. Computer simulation codes based on Hamiltonian dynamics, periodical boundary conditions and Morse potential function were used to simulate the nanoimprint processes. By varying the punch taper angle and the imprinting depth, useful information for nanoimprint process has been obtained.

  6. Deformation Mechanism and Punch Taper Effects on Nanoimprint Process by Molecular Dynamics

    NASA Astrophysics Data System (ADS)

    Hsu, Quang-Cherng; Wu, Chen-Da; Fang, Te-Hua

    2004-11-01

    A molecular dynamics analysis model is proposed to study the effects of parameters on the nanoimprint process, for example, taper angle, imprint depth and spring back. The nanoimprint process comprises one punch and one specimen at an isothermal state of 400 K, while the deformed material is a copper fcc single crystal and the punch material is a nickel fcc single crystal. There were a total of 10,080 atoms in copper measuring 12.02 nm and 5.72 nm in length and height, respectively. There were a total of 4,200 atoms in nickel with a typical length and depth in a punch tooth of 6.24 nm and 3.52 nm, respectively. Computer simulation codes based on Hamiltonian dynamics, periodical boundary conditions and the Morse potential function were used to simulate the nanoimprint process. By varying the punch taper angle and the imprint depth, useful information about the nanoimprint process was obtained.

  7. Characterization of New Punch Mutations: Identification of Two Additional Mutant Classes

    PubMed Central

    Reynolds, E. R.; O'Donnell, J. M.

    1988-01-01

    The Punch locus of Drosophila melanogaster which encodes the pteridine biosynthetic enzyme, GTP cyclohydrolase, is genetically complex. Lethal alleles of the locus resolve into an array of interallelic complementation groups, and at least one class of mutations is developmentally specific, affecting GTP cyclohydrolase activity only in the heads of adults. All previously isolated Punch alleles were identified on the basis of a mutant eye color phenotype. By screening mutagenized chromosomes over Punch region deficiencies, we have now isolated new alleles on the basis of lethal and visible phenotypes. Most of these alleles fall into previously identified genetic classes, but two new classes of mutations were also found. One class contains two alleles that behave as dominant lethal mutations in some genetic backgrounds. The other class represents a second developmentally specific set of alleles that affect the function of the Punch locus only during embryogenesis. PMID:3136053

  8. FEM analysis of springback control with lump-punch penetration after V-bending

    NASA Astrophysics Data System (ADS)

    Aso, Takayuki; Iizuka, Takashi

    2016-08-01

    In actual manufacturing, some empirical methods such as the bottoming technique are generally used in order to adjust the bend angles of products. However, the problem with this is that it relies on the technique of the engineer. In this study, quantitative springback control by lump-punch penetration after V-bending is investigated with FEM analysis and experimentation. The lump at the punch tip is pushed into a bent section at the final stage of V-bending and stretches the inside surface at the bent section. The method of springback control is suggested based on the deformation state. Then, the suitability of springback control using this mechanism is investigated. It is confirmed that the springback amount is reduced by lump-punch penetration. Accordingly, it is recommended to control springback by sheet forging with a lump punch.

  9. Performance Assessment of Hard Rock TBM and Rock Boreability Using Punch Penetration Test

    NASA Astrophysics Data System (ADS)

    Jeong, Ho-Young; Cho, Jung-Woo; Jeon, Seokwon; Rostami, Jamal

    2016-04-01

    Rock indentation tests are often called punch penetration tests and are known to be related to penetration rates of drilling equipment and hard rock tunnel boring machines (TBMs). Various indices determined from analysis of the force-penetration plot generated from indentation tests have been used to represent the drillability, boreability, and brittleness of rocks. However, no standard for the punch penetration test procedure or method for calculating the related indices has been suggested or adopted in the rock mechanics community. This paper introduces new indices based on the punch test to predict the performance of hard rock TBMs. A series of punch tests was performed on rock specimens representing six rock formations in Korea with different dimensions, i.e., the core specimens had different lengths and diameters. Of the indices obtained from the punch tests, the peak load index and mean load index showed good correlations with the cutting forces measured in full-scale linear cutting machine tests on the same rock types. The indices also showed good linear correlations with the ratio of uniaxial strength to Brazilian tensile strength, which indicates the brittleness of rock. The scale effect of using core specimens was investigated, and a preferred dimension for the punch test specimens is proposed. This paper also discusses the results of the punch test and full-scale rock cutting tests using LCM. The results of this study confirm that the proposed indices from the punch tests can be used to provide a reliable prediction of the cutting forces that act on a disc cutter. The estimated cutting forces can then be used for optimization of cutter-head design and performance prediction of hard rock TBMs.

  10. Correlation between shear punch and tensile data for neutron-irradiated aluminum alloys

    SciTech Connect

    Hamilton, M.L.; Edwards, D.J.; Toloczko, M.B.

    1995-04-01

    This work was performed to determine whether shear punch and tensile data obtained on neutron irradiated aluminum alloys exhibited the same type of relationship as had been seen in other work and to assess the validity of extrapolating the results to proton-irradiated alloys. This work was also meant to be the first of a series of similar test matrices designed to determine whether the shear punch/tensile relationship varied or was the same for different alloy classes.

  11. Dislocation punching from interfaces in functionally-graded materials

    SciTech Connect

    Taya, M.; Lee, J.K.; Mori, T.

    1997-06-01

    A new dislocation punching model for a functionally graded material (FGM) subjected to a temperature change is proposed, using Eshelby`s model. FGM, consisting of several layers, is deposited on a ceramic substrate. Two types of microstructures are examined for a layer: one consists of a metal matrix and ceramic particles and the other of a ceramic matrix and metal particles. An elastic energy is evaluated when plastic strain, in addition to thermal mismatch strain, is introduced in the metal phase. The work dissipated by the plastic deformation is also calculated. From the condition that the reduction in the elastic energy is larger than the work dissipated, a critical thermal mismatch strain to induce stress relaxation is determined. The magnitude of the plastic strain is also determined, when the relaxation occurs. The theory is applied to a model FGM consisting of mixtures of Pd and Al{sub 2}O{sub 3} on an Al{sub 2}O{sub 3} substrate.

  12. Tungsten Inert Gas and Friction Stir Welding Characteristics of 4-mm-Thick 2219-T87 Plates at Room Temperature and -196 °C

    NASA Astrophysics Data System (ADS)

    Lei, Xuefeng; Deng, Ying; Yin, Zhimin; Xu, Guofu

    2014-06-01

    2219-T87 aluminum alloy is widely used for fabricating liquid rocket propellant storage tank, due to its admirable cryogenic property. Welding is the dominant joining method in the manufacturing process of aerospace components. In this study, the tungsten inert gas welding and friction stir welding (FSW) characteristics of 4-mm-thick 2219-T87 alloy plate at room temperature (25 °C) and deep cryogenic temperature (-196 °C) were investigated by property measurements and microscopy methods. The studied 2219 base alloy exhibits a low strength plane anisotropy and excellent room temperature and cryogenic mechanical properties. The ultimate tensile strength values of TIG and FSW welding joints can reach 265 and 353 MPa at room temperature, and 342 and 438 MPa at -196 °C, respectively. The base metal consists of elongated deformed grains and many nano-scaled θ (Al2Cu) aging precipitates. Fusion zone and heat-affected zone (HAZ) of the TIG joint are characterized by coarsening dendritic grains and equiaxed recrystallized grains, respectively. The FSW-welded joint consists of the weld nugget zone, thermo-mechanically affected zone (TMAZ), and HAZ. In the weld nugget zone, a micro-scaled sub-grain structure is the main microstructure characteristic. The TMAZ and HAZ are both characterized by coarsened aging precipitates and elongated deformed grains. The excellent FSW welding properties are attributed to the preservation of the working structures and homogenous chemical compositions.

  13. FRACTURE TOUGHNESS OF 6.4 MM (0.25 INCH) ARC-CAST MOLOBDENUM AND MOLYBDENUM-TZM PLATE AT ROOM TEMPERATURE AND 300 DEGREES C

    SciTech Connect

    J. A. SHIELDS, JR.; P. LIPETZKY; A. J. MUELLER

    2001-04-11

    THE FRACTURE TOUGHNESS OF 6.4 mm (0.25 INCH) LOW CARBON ARC-CAST (LCAC) MOLYBDENUM AND ARC-CAST MOLYBDENUM-TZM ALLOY PLATE WERE MEASURED AT ROOM TEMPERATURE AND 300 DEGREES C USING COMPACT TNESION SPECIMENTS. THE EFFECT OF CRACK PLANE ORIENTATION (LONGITUDINAL VS. TRANSVERSE) AND ANNEALING PRACTICE (STRESS-RELIEVED VS. RECRYSTALLIZED) WERE EVALUATED. DEPENDING UPON THE TEST TEMPERATURE EITHER A STANDARD K[SUB]IC OR A J-INTEGRAL ANALYSIS WAS USED TO OBTAIN THE TOUGHNESS VALUE. AT ROOM TEMPERATURE, REGARDLESS OF ALLOY, ORIENTATION, OR MICROSTURECTURE, FRACTURE TOUGHNESS VALUES BETWEEN 15 AND 22 MPa m{sup 1/2} (14 AND 20 KSI IN{sup 1/2}) WERE MEASURED. THESE K[SUB]IC VALUES WERE CONSISTENT WITH MEASUREMENTS BY THE AUTHORS. INCREASING TEMPERATURE IMPROVES THE TOUGHNESS, DUE TO THE FACT THAT ONE TAKES ADVANTAGE OF THE DUCTIVE-BRITTLE TRANSITION BEHAVIOR OF MOLYBDENUM. AT 300 DEGREES C, THE FRACTURE TOUGHNESS OF RECRYSTALLIZED LCAC AND ARC-CAST TZM MOLYBDENUM WERE ALSO SIMILAR AT APPROXI MATELY 64 MPa m{sup 1/2} (58 KSI IN{sup 1/2}). IN THE STRESS-RELIEVED CONDITION, HOWEVER, THE TOUGHNESS OF ARC-CAST TZM (91 MPa m{sup 1/2}/83 KSI IN{sup 1/2}) WAS HIGHER THAN THAT OF THE LCAC MOLYBDENUM (74 MPa m{sup 1/2}/67 KSI IN{sup 1/2}).

  14. Stereotactic (Mammographically Guided) Breast Biopsy

    MedlinePlus

    ... Z Stereotactic Breast Biopsy Stereotactic breast biopsy uses mammography – a specific type of breast imaging that uses ... the breast are often detected by physical examination, mammography, or other imaging studies. However, it is not ...

  15. Celiac Disease Diagnosis: Endoscopic Biopsy

    MedlinePlus

    ... This is done in a procedure called a biopsy: the physician eases a long, thin tube called ... the tissue using instruments passed through the endoscope. Biopsy of the small intestine is the only way ...

  16. Aspiration and Biopsy: Bone Marrow

    MedlinePlus

    ... Help a Friend Who Cuts? Aspiration and Biopsy: Bone Marrow KidsHealth > For Teens > Aspiration and Biopsy: Bone Marrow Print A A A Text Size What's in ... Risks If You Have Questions What It Is Bone marrow aspirations and biopsies are performed to examine bone ...

  17. The endomyocardial biopsy.

    PubMed

    Schneiderman, H; Hager, W D; Gondos, B

    1986-01-01

    Endomyocardial biopsy (EMB) provides a safe, simple method of gathering unique information. Although the role of EMB continues to evolve rapidly, present consensus includes the following indications, based on the ability of EMB to provide diagnoses unobtainable by other means: assessment of early rejection following cardiac transplantation; determination of myocarditis as etiology of clinically obscure cardiac dysfunction; quantification of chemotherapeutic (especially anthracycline) cardiotoxicity; and distinction between constrictive and restrictive heart disease. Each of these indications carries major therapeutic as well as prognostic implications. Methods of processing EMB are presented, complications listed, artifacts described, findings and uses illustrated, and suggestions for future development addressed briefly.

  18. Telepathology and Optical Biopsy

    PubMed Central

    Ferrer-Roca, Olga

    2009-01-01

    The ability to obtain information about the structure of tissue without taking a sample for pathology has opened the way for new diagnostic techniques. The present paper reviews all currently available techniques capable of producing an optical biopsy, with or without morphological images. Most of these techniques are carried out by physicians who are not specialized in pathology and therefore not trained to interpret the results as a pathologist would. In these cases, the use of telepathology or distant consultation techniques is essential. PMID:20339507

  19. Methodology of stereotactic biopsy.

    PubMed

    Carapella, C M; Mastrostefano, R; Raus, L; Riccio, A

    1989-01-01

    The great technological improvement in the neurosurgical tools and in the neuroradiological imaging has brought about the diffusion of the stereotactic techniques. They are crucial for the diagnosis and treatment of intracranial expanding lesions of small dimensions or located in sites inaccessible to conventional techniques. The Authors describe the most common systems and methodologies for the stereotactic biopsy. They stress the importance of performing serial explorations which can provide evidence of the heterogeneity of the neoplastic lesion and of the infiltration of the brain adjacent to the tumor.

  20. How does prostate biopsy guidance error impact pathologic cancer risk assessment?

    NASA Astrophysics Data System (ADS)

    Martin, Peter R.; Gaed, Mena; Gómez, José A.; Moussa, Madeleine; Gibson, Eli; Cool, Derek W.; Chin, Joseph L.; Pautler, Stephen; Fenster, Aaron; Ward, Aaron D.

    2016-03-01

    Magnetic resonance imaging (MRI)-targeted, 3D transrectal ultrasound (TRUS)-guided "fusion" prostate biopsy aims to reduce the 21-47% false negative rate of clinical 2D TRUS-guided sextant biopsy, but still has a substantial false negative rate. This could be improved via biopsy needle target optimization, accounting for uncertainties due to guidance system errors, image registration errors, and irregular tumor shapes. As an initial step toward the broader goal of optimized prostate biopsy targeting, in this study we elucidated the impact of biopsy needle delivery error on the probability of obtaining a tumor sample, and on the core involvement. These are both important parameters to patient risk stratification and the decision for active surveillance vs. definitive therapy. We addressed these questions for cancer of all grades, and separately for high grade (>= Gleason 4+3) cancer. We used expert-contoured gold-standard prostatectomy histology to simulate targeted biopsies using an isotropic Gaussian needle delivery error from 1 to 6 mm, and investigated the amount of cancer obtained in each biopsy core as determined by histology. Needle delivery error resulted in variability in core involvement that could influence treatment decisions; the presence or absence of cancer in 1/3 or more of each needle core can be attributed to a needle delivery error of 4 mm. However, our data showed that by making multiple biopsy attempts at selected tumor foci, we may increase the probability of correctly characterizing the extent and grade of the cancer.

  1. Validation of the shear punch-tensile correlation technique using irradiated materials

    SciTech Connect

    Hankin, G.L.; Faulkner, R.G.; Toloczko, M.B.; Hamilton, M.L.

    1998-03-01

    It was recently demonstrated that tensile data could be successfully related to shear punch data obtained on transmission electron microscopy (TEM) discs for a variety of irradiated alloys exhibiting yield strengths that ranged from 100 to 800 MPa. This implies that the shear punch test might be a viable alternative for obtaining tensile properties using a TEM disk, which is much smaller than even the smallest miniature tensile specimens, especially when irradiated specimens are not available or when they are too radioactive to handle easily. The majority of the earlier tensile-shear punch correlation work was done using a wide variety of unirradiated materials. The current work extends this correlation effort to irradiated materials and demonstrates that the same relationships that related shear punch tests remain valid for irradiated materials. Shear punch tests were performed on two sets of specimens. In the first group, three simple alloys from the {sup 59}Ni isotopic doping series in the solution annealed and cold worked conditions were irradiated at temperatures ranging from 365 to 495 C in the Fast Flux Test Facility. The corresponding tensile data already existed for tensile specimens fabricated from the same raw materials and irradiated side-by-side with the disks. In the second group, three variants of 316 stainless steel were irradiated in FFTF at 5 temperatures between 400 and 730 C to doses ranging from 12.5 to 88 dpa. The specimens were in the form of both TEM and miniature tensile specimens and were irradiated side-by-side.

  2. Mesoscopic Nonlinear Elastic Modulus of Thermal Barrier Coatings Determined by Cylindrical Punch Indentation

    NASA Technical Reports Server (NTRS)

    Eldridge, Jeffrey I.; Zhu, Dong-Ming; Miller, Robert A.

    2000-01-01

    Cylindrical punch indentations are performed to determine the effective modulus of a plasma-sprayed ZrO2-8Wt%Y2O3 thermal barrier coating (TBC) as a function of coating depth. Cylindrical punch indentations offer significant advantages over pointed (Vickers, Berkovich, or Knoop) indentations for materials that do not exhibit linear elastic behavior. Cyclic loading with a cylindrical punch clearly shows the TBCs to exhibit nonlinear elastic behavior with significant hysteresis that is related to the compaction and internal sliding within the plasma-spray splat microstructure. In addition, the effect of a high heat flux laser treatment was shown to produce a gradient both in the effective TBC modulus and degree of loading/unloading hysteresis with depth.

  3. Effect of lubricant type and concentration on the punch tip adherence of model ibuprofen formulations.

    PubMed

    Roberts, Matthew; Ford, James L; MacLeod, Graeme S; Fell, John T; Smith, George W; Rowe, Philip H; Dyas, A Mark

    2004-03-01

    A model formulation, comprising ibuprofen and direct compression lactose (Tablettose 80) was used to assess the influence of two lubricants, magnesium stearate and stearic acid, on punch tip adherence. Lubricant concentrations were varied from 0.25% to 2% w/w. Formulations in the presence and absence of 0.5% w/w colloidal silica (Aerosil 200) were examined, to assess the influence of the glidant on the anti-adherent effects of the lubricants. Differential scanning calorimetry (DSC) was used to examine the effect of the lubricants on the melting temperature of ibuprofen. Tablets were compacted using a single punch tablet press at 10 kN using hard chrome-plated punches or at 40 kN using uncoated steel punches, tooling was 12.5-mm diameter in each case. The upper punch faces were characterized by obtaining Taylor Hobson Talysurf surface profiles. Following compaction, ibuprofen attached to the face was quantified by spectroscopy. At low concentrations of each lubricant, the levels of sticking observed were similar. Whilst sticking increased at magnesium stearate concentrations above 1%, sticking with stearic acid remained relatively constant at all concentrations. DSC revealed that the melting temperature of ibuprofen was lowered by the formation of eutectic mixtures with both lubricants. However, the onset temperature of melting and melting point were lowered to a greater extent with magnesium stearate compared with stearic acid. When using uncoated tooling at 40 kN, the deleterious effects of magnesium stearate on the tensile strength of the tablets also contributed to sticking. When using chrome-plated punches at 10 kN, the tensile strength reduction by the presence of magnesium stearate was less pronounced, as was the level of sticking.

  4. 29 CFR 570.59 - Occupations involved in the operations of power-driven metal forming, punching, and shearing...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... metal forming, punching, and shearing machines (Order 8). 570.59 Section 570.59 Labor Regulations... involved in the operations of power-driven metal forming, punching, and shearing machines (Order 8). Link..., and shearing machines: (i) All rolling machines, such as beading, straightening, corrugating,...

  5. Renal biopsy: methods and interpretation.

    PubMed

    Vaden, Shelly L

    2004-07-01

    Renal biopsy most often is indicated in the management of dogs and cats with glomerular disease or acute renal failure. Renal biopsy can readily be performed in dogs and cats via either percutaneous or surgical methods. Care should be taken to ensure that proper technique is used. When proper technique is employed and patient factors are properly addressed, renal biopsy is a relatively safe procedure that minimally affects renal function. Patients should be monitored during the post biopsy period for severe hemorrhage, the most common complication. Accurate diagnosis of glomerular disease, and therefore, accurate treatment planning,requires that the biopsy specimens not only be evaluated by light microscopy using special stains but by electron and immunofluorescent microscopy. PMID:15223207

  6. Elimination of false-positive polymerase chain reaction results resulting from hole punch carryover contamination.

    PubMed

    Bonne, Nicolai; Clark, Phillip; Shearer, Patrick; Raidal, Shane

    2008-01-01

    The collection of biological material (e.g., blood) directly onto filter paper for subsequent use in laboratory assays such as polymerase chain reaction (PCR), has become a common practice. Dried cells or fluid on the paper can be readily rehydrated and retrieved into a standard volume of an appropriate elution buffer but introduces a dilution factor to the sample. The use of a common cutting instrument for excising a standard-sized piece of paper that contains the material also introduces the potential for transferring biological material from one sample to subsequent samples, causing false-positive results by PCR. In the present study, filter-paper-collected blood that contained beak and feather disease virus was used to determine if viral DNA could be transferred between samples by a hole punch used to excise sequential filter papers. It was determined that false-positive results could be obtained at least 13 times after a positive sample. Subsequently, the efficacy of 4 methods of hole punch disinfection, flaming, VirkonS, bleach, and a bleach-ethanol combination, was assessed. The only effective and practical method to destroy DNA was a method where the hole punch was agitated in commercial bleach, rinsed in water, the water was displaced with 100% ethanol and air-dried. This method was simple, cheap, and relatively rapid, and allowed for the use of a single hole punch for a series of samples, without carryover contamination and consequent false-positive results.

  7. Obtaining full contact for measuring polydimethylsiloxane mechanical properties with flat punch nanoindentation.

    PubMed

    De Paoli, Federico; Volinsky, Alex A

    2015-01-01

    Procedure to establish full contact between the sample and the 1 mm diameter cylindrical flat punch tip to measure polydimethylsiloxane (PDMS) mechanical properties using the Hysitron TriboIndenter is described. This procedure differs from the standard automated indentation because each indent has to be performed manually after establishing full contact with the sample surface. Incomplete contact happens because of the sample tilt with respect to the flat punch surface and results in incorrect elastic modulus values.•Automated indentation results in incorrect values of the elastic modulus due to initial incomplete contact between the flat punch and the PDMS sample surface, caused by the tilt, and using the unloading slope, which is affected by viscoelastic soft polymer deformation.•Correct procedure requires establishing the full contact between the tip and the sample. This is achieved by moving the tip into the sample in 1-2 μm increments, up to 40-80 μm maximum combined displacement, until the loading stiffness no longer increases.•The elastic modulus is calculated from the loading stiffness and the diameter of the flat punch, instead of the unloading stiffness, which is larger due to viscoelastic unloading. After establishing the full contact, other mechanical testing can be conducted. PMID:26587387

  8. Investigating the effect of tablet thickness and punch curvature on density distribution using finite elements method.

    PubMed

    Diarra, Harona; Mazel, Vincent; Busignies, Virginie; Tchoreloff, Pierre

    2015-09-30

    Finite elements method was used to study the influence of tablet thickness and punch curvature on the density distribution inside convex faced (CF) tablets. The modeling of the process was conducted on 2 pharmaceutical excipients (anhydrous calcium phosphate and microcrystalline cellulose) by using Drucker-Prager Cap model in Abaqus(®) software. The parameters of the model were obtained from experimental tests. Several punch shapes based on industrial standards were used. A flat-faced (FF) punch and 3 convex faced (CF) punches (8R11, 8R8 and 8R6) with a diameter of 8mm were chosen. Different tablet thicknesses were studied at a constant compression force. The simulation of the compaction of CF tablets with increasing thicknesses showed an important change on the density distribution inside the tablet. For smaller thicknesses, low density zones are located toward the center. The density is not uniform inside CF tablets and the center of the 2 faces appears with low density whereas the distribution inside FF tablets is almost independent of the tablet thickness. These results showed that FF and CF tablets, even obtained at the same compression force, do not have the same density at the center of the compact. As a consequence differences in tensile strength, as measured by diametral compression, are expected. This was confirmed by experimental tests. PMID:26200746

  9. Effect of feeding fermented rice punch on oestrous induction in anoestrous bitches

    PubMed Central

    Choi, Eul-Soo; Yang, Byoung-Chul; Park, Pu-Rum; Chae, Jung-Il; Kim, Dong-Ku; Yoo, Jae-Kyu; Kim, Dong-Hoon; Cho, Kyu-Woan; Kong, Il-Keun

    2015-01-01

    Introduction As a consequence of poor productivity caused by a long anoestrous period, considerable research effort has been given to oestrus induction in dogs to enhance the productivity of young dogs and to preserve breeds. Materials and methods Oestrus was induced in 30 anoestrous bitches more than three months after the last oestrus. Bitches orally received fermented rice punch with or without bromocriptine once daily for 21 consecutive days. The bitches were divided into two groups (n=10 per group): Group (1) fed fermented rice punch and Group (2) administered bromocriptine (100 µg/kg/day) and fed fermented rice punch. Results The concentration of dopamine in fermented rice punch was 47.2 mg/kg (parts per million). Six of 10 (60.0 per cent) and seven of 10 (70.0 per cent) bitches showed pro-oestrual bleeding in Groups 1 and 2, respectively. The mean and median values (min–max) to oestrus induction was not significantly different between Groups 1 and 2 (9.7±7.3, 6.5 (3–22) and 11.3±6.6, 7.9 (5–21) days) after treatment commencement (P>0.05). The pregnancy rate was very similar between Groups 1, 2 (66.0%) and control (66.0, 57.0 and 50.0 per cent). The mean and median values (min–max) of pups per bitch are also not significantly different between Groups 1, 2 and control (7.0±1.8, 7.0 (5–9) and 7.5±2.1, 7.5 (5–10) and 7.0±0, 7.0 (7–7)). Conclusion We suggest that rice punch effectively induces oestrus in bitches. PMID:26392895

  10. Multidrug punch cards in primary care: a mixed methods study on patients' preferences and impact on adherence

    PubMed Central

    Boeni, Fabienne; Hersberger, Kurt E.; Arnet, Isabelle

    2014-01-01

    Background: Multidrug punch cards are frame cards with 28 plastic cavities filled with a patient's oral solid medication. They are used in primary care to facilitate medication management and to enhance adherence. Main criticism concerned handling difficulties and fading knowledge about medication of patients using them. This study aimed at exploring daily use, preferences, and adherence of primary care patients using multidrug punch cards. Methods: Community pharmacies in Switzerland recruited primary care patients using multidrug punch cards. A mixed methods approach was applied with quantitative interviews performed by telephone and qualitative interviews face-to-face. Results: Of 149 eligible patients from 21 community pharmacies, 22 participated 2011 in the quantitative and 11 participated 2013/14 in the qualitative interview. Patients were very satisfied with the multidrug punch cards and stated increased medication safety. All considered adherence as very important. Self-reported adherence was 10 (median) on a visual analog scale (0 = no intake, 10 = perfect adherence). The absence of package inserts and predefined handling difficulties e.g., tablets spiking at removal were not perceived as problems. Conclusions: Patients are satisfied with the multidrug punch cards, feel safe, mostly have no handling problems and adhere to their treatment. Trust in health-care professionals and patients' experiences emerged as key variables for initiating multidrug punch card use and for medication adherence. This mixed methods study invalidates previous concerns about disadvantages of multidrug punch cards. Health-care professionals should actively recommend them for primary care patients with polypharmacy and poor adherence. PMID:25324777

  11. Effects of surface roughness and chrome plating of punch tips on the sticking tendencies of model ibuprofen formulations.

    PubMed

    Roberts, Matthew; Ford, James L; MacLeod, Graeme S; Fell, John T; Smith, George W; Rowe, Philip H

    2003-09-01

    The sticking of three model ibuprofen-lactose formulations with respect to compaction force and the surface quality of the upper punch were assessed. Compaction was performed at 10, 25 or 40 kN using an instrumented single-punch tablet press. Two sets of 12.5-mm flat-faced punches were used to evaluate the influence of surface quality. A third set of chrome-plated tooling was also used. Surface profiles (Taylor Hobson Talysurf 120) of the normal tooling upper punches indicated a large difference in quality. The punches were subsequently classified as old (Ra = 0.33 microm) or new (Ra = 0.04 microm) where Ra is the mean of all positive deviations from zero. Surface profiles of sample tablets were also obtained. Following compaction, ibuprofen attached to the face was quantified by spectroscopy. Punch surface roughness, compaction force and the blend composition were all significant factors contributing to sticking. Chrome plating of punch faces increased sticking at a low compaction force but decreased sticking at higher forces. Surface roughness of the tablets did not correlate with the corresponding data for sticking, indicating that this is not a suitable method of quantifying sticking.

  12. Bone biopsy in haematological disorders.

    PubMed Central

    Burkhardt, R; Frisch, B; Bartl, R

    1982-01-01

    Bone marrow biopsies are now widely used in the investigation and follow-up of many diseases. Semi-thin sections of 8216 undecalcified biopsies of patients with haematological disorders were studied. Observations were made on the cytopenias and the myelodysplastic syndromes, the acute leukaemias the myeloproliferative disorders, Hodgkin's disease and the malignant lymphomas including multiple myeloma, hairy cell leukaemia and angioimmunoblastic lymphadenopathy. Bone marrow biopsies are essential for the differential diagnosis of most cytopenias and for the early recognition of fibrosis which most frequently occurred as a consequence of megakaryocytic proliferation in the myeloproliferative disorders. Different patterns of bone marrow involvement were found in the lymphoproliferative disorders and both their type and extent constituted factors of prognostic significance. A survey of the literature is given and the conclusion is drawn that bone marrow biopsies provide indispensible information for the diagnostic evaluation and the follow-up of patients with haematological disorders. Images PMID:7040489

  13. Gram stain of tissue biopsy

    MedlinePlus

    ... stain of tissue biopsy test involves using crystal violet stain to test a sample of tissue taken ... microscope slide. The specimen is stained with crystal violet stain and goes through more processing before it ...

  14. A PET/CT Directed, 3D Ultrasound-Guided Biopsy System for Prostate Cancer

    PubMed Central

    Master, Viraj; Nieh, Peter; Akbari, Hamed; Yang, Xiaofeng; Fenster, Aaron; Schuster, David

    2015-01-01

    Prostate cancer affects 1 in 6 men in the USA. Systematic transrectal ultrasound (TRUS)-guided biopsy is the standard method for a definitive diagnosis of prostate cancer. However, this “blind” biopsy approach can miss at least 20% of prostate cancers. In this study, we are developing a PET/CT directed, 3D ultrasound image-guided biopsy system for improved detection of prostate cancer. In order to plan biopsy in three dimensions, we developed an automatic segmentation method based wavelet transform for 3D TRUS images of the prostate. The segmentation was tested in five patients with a DICE overlap ratio of more than 91%. In order to incorporate PET/CT images into ultrasound-guided biopsy, we developed a nonrigid registration algorithm for TRUS and PET/CT images. The registration method has been tested in a prostate phantom with a target registration error (TRE) of less than 0.4 mm. The segmentation and registration methods are two key components of the multimodality molecular image-guided biopsy system. PMID:26866061

  15. Experience with transjugular liver biopsy.

    PubMed Central

    Bull, H J; Gilmore, I T; Bradley, R D; Marigold, J H; Thompson, R P

    1983-01-01

    The results of 193 transjugular liver biopsies performed with a modified needle are described. An adequate specimen was obtained in 97%, and complications were rare, although puncture of the liver capsule does occur and caused bleeding in two patients. Fever after the procedure was reduced by ultrasonic cleaning of the needle. Although not easy, this technique is safe and preferable in the management of selected patients, but in most patients percutaneous biopsy is to be preferred. PMID:6629116

  16. [Possibilities for injuries caused by rubber bullets from the self-defense weapon MR 35 Punch].

    PubMed

    Schyma, C; Schyma, P

    1997-01-01

    Manurhin developed a "non lethal" weapon, the MR 35 Punch, which fires 21 g weighing rubber balls of 35 mm caliber. The black powder cartridges which were used as propellant cause important variations of the projectile's velocity from 120 to 140 m/s. The resulting energies were about 150 to 200 J. The wounding potential was examined by shots on different materials and gelatin. Shots from 2 to 5 m distance caused penetrations of 3 to 8 cm in 10 percent gelatin. Covering the gelatin with skin or thick textiles did not significantly change the penetration. Skin and textiles were penetrated in all experiments. Pieces of flat bone which were embedded in gelatin were fractured by the shots, in part fracture elements were dislocated. The discussion of the wound ballistic results contradict the "non lethal" character of the MR 35 Punch. PMID:9446526

  17. The development of a tensile-shear punch correlation for yield properties of model austenitic alloys

    SciTech Connect

    Hankin, G.L.; Faulkner, R.G.; Hamilton, M.L.; Garner, F.A.

    1997-08-01

    The effective shear yield and maximum strengths of a set of neutron-irradiated, isotopically tailored austentic alloys were evaluated using the shear punch test. The dependence on composition and neutron dose showed the same trends as were observed in the corresponding miniature tensile specimen study conducted earlier. A single tensile-shear punch correlation was developed for the three alloys in which the maximum shear stress or Tresca criterion was successfully applied to predict the slope. The correlation will predict the tensile yield strength of the three different austenitic alloys tested to within {+-}53 MPa. The accuracy of the correlation improves with increasing material strength, to within {+-} MPa for predicting tensile yield strengths in the range of 400-800 MPa.

  18. [Flexible bronchoscopy techniques: bronchoalveolar lavage, bronchial biopsy and transbronchial biopsy].

    PubMed

    Escribano Montaner, A; Moreno Galdó, A

    2005-04-01

    This article completes previous recommendations of the Techniques Group of the Spanish Society of Pediatric Pulmonologists on the practice of flexible bronchoscopy in children. We review the most frequently performed diagnostic and therapeutic procedures applied through the flexible bronchoscope: bronchoalveolar lavage, bronchial biopsy and transbronchial biopsy. Recommendations are also provided on the practice of nonbronchoscopic bronchoalveolar lavage. We review the indications and contraindications of these techniques, the equipment required, and the preparation and monitoring of the patient before, during and after the procedure. The complications of these techniques are also discussed. These recommendations may be adopted, modified or rejected according to clinical needs and constraints.

  19. Using Teamcenter engineering software for a successive punching tool lifecycle management

    NASA Astrophysics Data System (ADS)

    Blaga, F.; Pele, A.-V.; Stǎnǎşel, I.; Buidoş, T.; Hule, V.

    2015-11-01

    The paper presents studies and researches results of the implementation of Teamcenter (TC) integrated management of a product lifecycle, in a virtual enterprise. The results are able to be implemented also in a real enterprise. The product was considered a successive punching and cutting tool, designed to materialize a metal sheet part. The paper defines the technical documentation flow (flow of information) in the process of constructive computer aided design of the tool. After the design phase is completed a list of parts is generated containing standard or manufactured components (BOM, Bill of Materials). The BOM may be exported to MS Excel (.xls) format and can be transferred to other departments of the company in order to supply the necessary materials and resources to achieve the final product. This paper describes the procedure to modify or change certain dimensions of sheet metal part obtained by punching. After 3D and 2D design, the digital prototype of punching tool moves to following lifecycle phase of the manufacturing process. For each operation of the technological process the corresponding phases are described in detail. Teamcenter enables to describe manufacturing company structure, underlying workstations that carry out various operations of manufacturing process. The paper revealed that the implementation of Teamcenter PDM in a company, improves efficiency of managing product information, eliminating time working with search, verification and correction of documentation, while ensuring the uniqueness and completeness of the product data.

  20. Tensile-shear correlations obtained from shear punch test technique using a modified experimental approach

    NASA Astrophysics Data System (ADS)

    Karthik, V.; Visweswaran, P.; Vijayraghavan, A.; Kasiviswanathan, K. V.; Raj, Baldev

    2009-09-01

    Shear punch testing has been a very useful technique for evaluating mechanical properties of irradiated alloys using a very small volume of material. The load-displacement data is influenced by the compliance of the fixture components. This paper describes a modified experimental approach where the compliances of the punch and die components are eliminated. The analysis of the load-displacement data using the modified setup for various alloys like low carbon steel, SS316, modified 9Cr-1Mo, 2.25Cr-1Mo indicate that the shear yield strength evaluated at 0.2% offset of normalized displacement relates to the tensile YS as per the Von Mises yield relation ( σys = 1.73 τys). A universal correlation of type UTS = mτmax where m is a function of strain hardening exponent, is seen to be obeyed for all the materials in this study. The use of analytical models developed for blanking process are explored for evaluating strain hardening exponent from the load-displacement data. This study is directed towards rationalizing the tensile-shear empirical correlations for a more reliable prediction of tensile properties from shear punch tests.

  1. Is an Elective Neck Dissection Necessary for All Cases of N0 Oral Squamous Cell Carcinoma? -Elective Neck Dissection may be Performed for Tongue Cancer with Tumor Thickness More than 4 mm.

    PubMed

    Otsuru, Mitsunobu; Aoki, Takayuki; Ota, Yoshihide; Denda, Yuya; Akiba, Takeshi; Sekine, Riyo; Yoshida, Yoshifumi; Osaka, Ryuta

    2016-01-01

    We investigated whether neck dissection should be performed to prevent T1-2N0M0 tongue cancer by using the Weiss and colleague's decision tree method. The results showed that preventive neck dissection should not be recommended for T1-2N0M0 tongue cancer. However, preventive neck dissection is a suitable approach when treating tongue cancer tumors with a thickness of ≥ 4 mm. PMID:27628601

  2. Oral biopsy: oral pathologist's perspective.

    PubMed

    Kumaraswamy, K L; Vidhya, M; Rao, Prasanna Kumar; Mukunda, Archana

    2012-01-01

    Many oral lesions may need to be diagnosed by removing a sample of tissue from the oral cavity. Biopsy is widely used in the medical field, but the practice is not quite widespread in dental practice. As oral pathologists, we have found many artifacts in the tissue specimen because of poor biopsy technique or handling, which has led to diagnostic pitfalls and misery to both the patient and the clinician. This article aims at alerting the clinicians about the clinical faults arising preoperatively, intraoperatively and postoperatively while dealing with oral biopsy that may affect the histological assessment of the tissue and, therefore, the diagnosis. It also reviews the different techniques, precautions and special considerations necessary for specific lesions.

  3. An approach to duodenal biopsies

    PubMed Central

    Serra, S; Jani, P A

    2006-01-01

    The introduction of endoscopy of the upper digestive tract as a routine diagnostic procedure has increased the number of duodenal biopsy specimens. Consequently, the pathologist is often asked to evaluate them. In this review, a practical approach to the evaluation of a duodenal biopsy specimen is discussed. An overview of the handling of specimens is given and the normal histology and commonly encountered diseases are discussed. Finally, a description of commonly seen infections is provided, together with an algorithmic approach for diagnosis. PMID:16679353

  4. How boxers decide to punch a target: emergent behaviour in nonlinear dynamical movement systems.

    PubMed

    Hristovski, Robert; Davids, Keith; Araújo, Duarte; Button, Chris

    2006-01-01

    Previous research has shown how dynamical systems theory provides a relevant framework for investigating decision-making behavior in sport. The aim of this study was to adopt concepts and tools from nonlinear dynamics in examining effects of boxer-target distance and perceived punching efficiency on emergent decision-making during a typical practice task in boxing. Results revealed the existence of critical values of scaled distances between boxers and targets for first time appearance and disappearance of a diverse range of boxing actions including jabs, hooks and uppercuts. Reasons for the diversity of actions were twofold: i) abrupt (qualitative) changes in the number of the possible punches, i.e. motor solutions to the hitting task; and ii), fine modification of the probabilities of selecting specific striking patterns. Boxers were able to exploit the emerging perception of strikeability, leading to a changing diversity of selected actions and a cascade of abrupt changes in the perceptual-motor work space of the task. Perceived efficiency of a punching action by the participants also changed as a function of the scaled distance to a target and was correlated with the probability of occurrence of specific boxing actions. Accordingly, scaled distance-dependent perceived efficiency seems an important perceptual constraint in the training task of punching a heavy bag in boxers. Key PointsDuring the practicing with static (i.e. non moving) heavy bags novice boxers' perceptual-action system is sensitive to the scaled distance and efficiency informational constraints. These interdependent constraints shape the action behaviour of the novice boxers;During heavy bag practice novice boxers are subject to a kind of discovery learning by exploring the efficiency of their motor repertoire when changing the performer - target distances;The region close to D = 0.6 maximizes the flexibility of switching among different types of punching actions and is optimal for practicing

  5. How Boxers Decide to Punch a Target: Emergent Behaviour in Nonlinear Dynamical Movement Systems

    PubMed Central

    Hristovski, Robert; Davids, Keith; Araújo, Duarte; Button, Chris

    2006-01-01

    Previous research has shown how dynamical systems theory provides a relevant framework for investigating decision-making behavior in sport. The aim of this study was to adopt concepts and tools from nonlinear dynamics in examining effects of boxer-target distance and perceived punching efficiency on emergent decision-making during a typical practice task in boxing. Results revealed the existence of critical values of scaled distances between boxers and targets for first time appearance and disappearance of a diverse range of boxing actions including jabs, hooks and uppercuts. Reasons for the diversity of actions were twofold: i) abrupt (qualitative) changes in the number of the possible punches, i.e. motor solutions to the hitting task; and ii), fine modification of the probabilities of selecting specific striking patterns. Boxers were able to exploit the emerging perception of strikeability, leading to a changing diversity of selected actions and a cascade of abrupt changes in the perceptual-motor work space of the task. Perceived efficiency of a punching action by the participants also changed as a function of the scaled distance to a target and was correlated with the probability of occurrence of specific boxing actions. Accordingly, scaled distance-dependent perceived efficiency seems an important perceptual constraint in the training task of punching a heavy bag in boxers. Key Points During the practicing with static (i.e. non moving) heavy bags novice boxers' perceptual-action system is sensitive to the scaled distance and efficiency informational constraints. These interdependent constraints shape the action behaviour of the novice boxers; During heavy bag practice novice boxers are subject to a kind of discovery learning by exploring the efficiency of their motor repertoire when changing the performer - target distances; The region close to D = 0.6 maximizes the flexibility of switching among different types of punching actions and is optimal for practicing

  6. Vacuum enhanced cutaneous biopsy instrument

    DOEpatents

    Collins, Joseph

    2000-01-01

    A syringe-like disposable cutaneous biopsy instrument equipped with a tubular blade at its lower end, and designed so that a vacuum is created during use, said vacuum serving to retain undeformed a plug of tissue cut from a patient's skin.

  7. Biopsy techniques for intraocular tumors

    PubMed Central

    Rishi, Pukhraj; Dhami, Abhinav; Biswas, Jyotirmay

    2016-01-01

    Biopsy involves the surgical removal of a tissue specimen for histopathologic evaluation. Most intraocular tumors are reliably diagnosed based on the clinical evaluation or with noninvasive diagnostic techniques. However, accurately diagnosing a small percentage of tumors can be challenging. A tissue biopsy is thus needed to establish a definitive diagnosis and plan the requisite treatment. From fine-needle aspiration biopsy (FNAB) to surgical excision, all tissue collection techniques have been studied in the literature. Each technique has its indications and limitations. FNAB has been reported to provide for 88–95% reliable and safe ophthalmic tumor diagnosis and has gained popularity for prognostic purposes and providing eye conserving treatment surgeries. The technique and instrumentation for biopsy vary depending upon the tissue involved (retina, choroid, subretinal space, vitreous, and aqueous), suspected diagnosis, size, location, associated retinal detachment, and clarity of the media. The cytopathologist confers a very important role in diagnosis and their assistance plays a key role in managing and planning the treatment for malignancies. PMID:27488148

  8. Vacuum Enhanced Cutaneous Biopsy Instrument

    SciTech Connect

    Collins, Joseph

    1999-06-25

    A syringe-like disposable cutaneous biopsy instrument equipped with a tubular blade at its lower end, and designed so that a vacuum is created during use, said vacuum serving to retain undeformed a plug of tissue cut from a patient's skin.

  9. On the prediction of impact noise, Part IX: The noise from punch presses

    NASA Astrophysics Data System (ADS)

    Richards, E. J.; Stimpson, G. J.

    1985-11-01

    The punch press is a further classical example of impact noise: the force is built up in the punch relatively slowly, and the whole machine is strained until the load on the material being punched reaches a yield and shortly afterwards a fracture level. At this stage the strain energy in the machine and its workpiece must be redistributed and this leads to vibration of the whole machine and to noise radiation. In this paper work which has been carried out at ISVR over a number of years is presented. It describes the way the Energy Accountancy Equation [1] can be modified to relate the noise radiated directly to the sum of the squares of the large rates of change of force against time, and illustrates clearly the way that noise control, with use of passive or active methods in designing the punch tooling, can be related directly to the one parameter 10 log Σ[ f( t)] max2. It is shown that noise levels can be reduced by up to 30 dB under ideal conditions by fracture pulse tailoring while still cutting metal, but that more realistically, 10 dB reductions may be obtained below those of current practice by practical tool design. An explanation is given of why large open presses are never likely to achieve the proposed factory noise levels and that the noise from double-sided presses can be controlled effectively by tooling modifications and by the addition of damping. The paper describes work carried out on passive and active cancellation systems used to arrest and springback of the press structure following workpiece material fracture and explains the practical limitations of such systems. Active techniques are limited by the difficulties obtained, with brittle hard materials, of finding a trigger and load freezing system which can operate fast enough to reduce adequately the force parameter 10 log Σ ( fmax( t)) 2. Where punching finish allows, it has been found that well-designed shear and/or cutting with low percentage clearance is superior to active cancellation

  10. Measuring Polydimethylsiloxane (PDMS) Mechanical Properties Using Flat Punch Nanoindentation Focusing on Obtaining Full Contact

    NASA Astrophysics Data System (ADS)

    De Paoli, Federico

    In this research, the materials used were the Polydimethylsiloxane (PDMS) polymers. PDMS mechanicals properties were measured using a customized version of the nanoindentation test using a flat punch tip. The method is proposed in Chapter 3 and it is used to calculate the elastic modulus of different PDMS samples. The samples tested were both produced specifically for this research and available in the laboratory's storage. They all present different levels of cross-linking degree. It is quite common to not have full contact between the cylindrical flat punch and the sample because of the unavoidable tilt. The new method guarantees establishing full contact between the sample and the tip. The tip used for this purpose is a flat punch tip. The Young's moduli of the following samples were calculated: 10:1, 30:1 and 50:1. The Young's moduli found were: 2.85+/-0.001 MPa for the 10:1 sample, 0.34+/-0.001 MPa for the 30:1 sample and 0.15+/-0.002 MPa for the 50:1 sample. All the experiments were repeated at least three times to assure the validity and the repeatability of the method. The results were then compared with values available in the literature. The same method was applied to analyze the viscosity of the samples. Even if a mathematical result was not obtained, data and analysis through graphical representations are available in this thesis. The sample tested was a PDMS sample with a cross-linking degree of 30:1. The experiment has been repeated three times.

  11. Electromagnetic secondaries and punch-through effects in the CMS ME1/1

    NASA Astrophysics Data System (ADS)

    Belotelov, I. I.; Golunov, A. O.; Golutvin, I. A.; Gorbunov, N. V.; Karjavin, V. Yu.; Kiryushin, Yu. T.; Kamenev, A. Yu.; Khabarov, S. V.; Khabarov, V. V.; Mescheryakov, G. V.; Moissenz, K. P.; Moissenz, P. V.; Movchan, S. A.; Palichik, V. V.; Perelygin, V. V.; Shmatov, S. V.; Smolin, D. A.; Zarubin, A. V.

    2007-07-01

    The aim of this work is to estimate the shower leakage from the CMS Endcap Hadron calorimeter (HE) due to electromagnetic secondaries and punch-through in the region of the ME1/1 Forward Muon Station. Two configurations are considered: with and without the CMS Endcap Electromagnetic calorimeter (EE). The experimental data have been taken during the combined beam test of CMS subdetectors (HE, ME, RPC, DT) at the CERN H2 beam facility in 2004. Serial CSC chambers (ready for installation in CMS) fully equipped with readout electronics have been exposed. Simulation of a beam test setup has been performed using the GEANT4-based simulation software package OSCAR.

  12. Shear Punch Properties of Low Activation Ferritic Steels Following Irradiation in ORR

    SciTech Connect

    Ermi, Ruby M.; Hamilton, Margaret L.; Gelles, David S.; Ermi, August M.

    2001-10-01

    Shear punch post-irradiation test results are reported for a series of low activation steels containing Mn following irradiation in the Oak Ridge Reactor at 330 and 400 degrees centigrade to {approx}10 dpa. Alloy compositions included 2Cr, 9Cr and 12Cr steels with V to 1.5% and W to 1.0%. Comparison of results with tensile test results showed good correlations with previously observed trends except where disks were improperly manufactured because they were too thin or because engraving was faulty.

  13. Biopsies

    MedlinePlus

    ... computed tomography (CT) , fluoroscopy , ultrasound , or MRI . A mammography unit is a rectangular box that houses the ... seen. Some lesions, such as clustered calcifications on mammography are not as clearly shown with ultrasound as ...

  14. Biopsy

    MedlinePlus

    ... Sections of the JAOCD JAOCD Archive Published Members Online Dermatology Journals Edit This Favorite Name: Category: Share: Yes ... 2/2017 2017 AOCD Spring Current Concepts in Dermatology Meeting more Latest News ... Surveys About AOCD The AOCD was recognized in ...

  15. Liquid biopsy in liver cancer.

    PubMed

    Labgaa, Ismail; Villanueva, Augusto

    2015-04-01

    Liver cancer has become the second cause of cancer-related death worldwide. Most patients are still diagnosed at intermediate or advanced stage, where potentially curative treatment options are not recommended. Unlike other solid tumors, there are no validated oncogenic addiction loops and the only systemic agent to improve survival in advanced disease is sorafenib. All phase 3 clinical trials testing molecular therapies after sorafenib have been negative, none of which selected patients based on predictive biomarkers of response. Theoretically, analysis of circulating cancer byproducts (e.g., circulating tumor cells, cell-free nucleic acids), namely "liquid biopsy," could provide easy access to molecular tumor information, improve patients' stratification and allow to assess tumor dynamics over time. Recent technical developments and preliminary data from other malignancies indicate that liquid biopsy might have a role in the future management of cancer patients. PMID:25977189

  16. 20 CFR 718.106 - Autopsy; biopsy.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... DUE TO PNEUMOCONIOSIS Criteria for the Development of Medical Evidence § 718.106 Autopsy; biopsy. (a... does not have pneumoconiosis. However, where positive findings are obtained on biopsy, the results will constitute evidence of the presence of pneumoconiosis....

  17. 20 CFR 718.106 - Autopsy; biopsy.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... DUE TO PNEUMOCONIOSIS Criteria for the Development of Medical Evidence § 718.106 Autopsy; biopsy. (a... does not have pneumoconiosis. However, where positive findings are obtained on biopsy, the results will constitute evidence of the presence of pneumoconiosis....

  18. Testing Biopsy and Cytology Specimens for Cancer

    MedlinePlus

    ... articles window. My Saved Articles » My ACS » Testing Biopsy and Cytology Specimens for Cancer Download Printable Version [ ... on the topics below to get started. Testing Biopsy and Cytology Specimens for Cancer How is cancer ...

  19. Punching Out.

    ERIC Educational Resources Information Center

    Hill, David

    2000-01-01

    Presents the story of the number one for-profit school in the United States, the Thomas A. Edison Charter Academy. Teachers had a heavier workload, but better pay and perks. Shortly after opening, many teachers were discontent with the long days and calendar, lack of follow through on promised benefits, and other issues. Reactions to this…

  20. Punch List

    ERIC Educational Resources Information Center

    Biemiller, Lawrence

    2008-01-01

    This article features university architect Ron McCoy and describes his work at the Arizona State University (ASU). McCoy, now on his fifth year of overseeing construction on all four Arizona State campuses, came to ASU 14 years ago as a professor and director of the School of Architecture and Landscape Architecture. He was thinking seriously about…

  1. Stress concentration in periodically rough Hertzian contact: Hertz to soft-flat-punch transition

    NASA Astrophysics Data System (ADS)

    Ledesma-Alonso, R.; Raphaël, E.; Léger, L.; Restagno, F.; Poulard, C.

    2016-09-01

    We report on the elastic contact between a spherical lens and a patterned substrate, composed of a hexagonal lattice of cylindrical pillars. The stress field and the size of the contact area are obtained by means of numerical methods: a superposition method of discrete pressure elements and an iterative bisection-like method. For small indentations, a transition from a Hertzian to a soft-flat-punch behaviour is observed when the surface fraction of the substrate that is covered by the pillars is increased. In particular, we present a master curve defined by two dimensionless parameters, which allows one to predict the stress at the centre of the contact region in terms of the surface fraction occupied by pillars. The transition between the limiting contact regimes, Hertzian and soft-flat-punch, is well described by a rational function. Additionally, a simple model to describe the Boussinesq-Cerruti-like contact between the lens and a single elastic pillar, which takes into account the pillar geometry and the elastic properties of the two bodies, is presented.

  2. Fretting contact of a functionally graded piezoelectric layered half-plane under a conducting punch

    NASA Astrophysics Data System (ADS)

    Su, Jie; Ke, Liao-Liang; Wang, Yue-Sheng

    2016-02-01

    This paper investigates the fretting contact between a functionally graded piezoelectric layered half-plane and a rigid cylindrical punch. The electro-elastic properties of functionally graded piezoelectric materials (FGPMs) vary exponentially along the thickness direction. It is assumed that the punch is a perfect conductor with a constant electric potential within the contact region. The two bodies are brought into contact first by a monotonically increasing normal load, and then by a cyclic tangential load which is less than that necessary to cause complete sliding. The whole contact region is composed of an inner stick region and two outer slip regions in which Coulomb’s friction law is assumed. The problem is reduced to a set of coupled Cauchy singular integral equations by using the Fourier integral transform technique and the superposition theorem. An iterative method is used to determine the unknown stick/slip region, normal contact pressure, electric charge and tangential traction. The effects of the resultant electric charge and gradient index on the surface electromechanical fields are discussed during different loading phases. It is found that FGPMs could potentially be applied to improve fretting contact damage in smart devices.

  3. Complementary Post Transcriptional Regulatory Information is Detected by PUNCH-P and Ribosome Profiling

    PubMed Central

    Zur, Hadas; Aviner, Ranen; Tuller, Tamir

    2016-01-01

    Two novel approaches were recently suggested for genome-wide identification of protein aspects synthesized at a given time. Ribo-Seq is based on sequencing all the ribosome protected mRNA fragments in a cell, while PUNCH-P is based on mass-spectrometric analysis of only newly synthesized proteins. Here we describe the first Ribo-Seq/PUNCH-P comparison via the analysis of mammalian cells during the cell-cycle for detecting relevant differentially expressed genes between G1 and M phase. Our analyses suggest that the two approaches significantly overlap with each other. However, we demonstrate that there are biologically meaningful proteins/genes that can be detected to be post-transcriptionally regulated during the mammalian cell cycle only by each of the approaches, or their consolidation. Such gene sets are enriched with proteins known to be related to intra-cellular signalling pathways such as central cell cycle processes, central gene expression regulation processes, processes related to chromosome segregation, DNA damage, and replication, that are post-transcriptionally regulated during the mammalian cell cycle. Moreover, we show that combining the approaches better predicts steady state changes in protein abundance. The results reported here support the conjecture that for gaining a full post-transcriptional regulation picture one should integrate the two approaches. PMID:26898226

  4. Optimal design of a main driving mechanism for servo punch press based on performance atlases

    NASA Astrophysics Data System (ADS)

    Zhou, Yanhua; Xie, Fugui; Liu, Xinjun

    2013-09-01

    The servomotor drive turret punch press is attracting more attentions and being developed more intensively due to the advantages of high speed, high accuracy, high flexibility, high productivity, low noise, cleaning and energy saving. To effectively improve the performance and lower the cost, it is necessary to develop new mechanisms and establish corresponding optimal design method with uniform performance indices. A new patented main driving mechanism and a new optimal design method are proposed. In the optimal design, the performance indices, i.e., the local motion/force transmission indices ITI, OTI, good transmission workspace good transmission workspace(GTW) and the global transmission indices GTIs are defined. The non-dimensional normalization method is used to get all feasible solutions in dimensional synthesis. Thereafter, the performance atlases, which can present all possible design solutions, are depicted. As a result, the feasible solution of the mechanism with good motion/force transmission performance is obtained. And the solution can be flexibly adjusted by designer according to the practical design requirements. The proposed mechanism is original, and the presented design method provides a feasible solution to the optimal design of the main driving mechanism for servo punch press.

  5. Predicting punching acceleration from selected strength and power variables in elite karate athletes: a multiple regression analysis.

    PubMed

    Loturco, Irineu; Artioli, Guilherme Giannini; Kobal, Ronaldo; Gil, Saulo; Franchini, Emerson

    2014-07-01

    This study investigated the relationship between punching acceleration and selected strength and power variables in 19 professional karate athletes from the Brazilian National Team (9 men and 10 women; age, 23 ± 3 years; height, 1.71 ± 0.09 m; and body mass [BM], 67.34 ± 13.44 kg). Punching acceleration was assessed under 4 different conditions in a randomized order: (a) fixed distance aiming to attain maximum speed (FS), (b) fixed distance aiming to attain maximum impact (FI), (c) self-selected distance aiming to attain maximum speed, and (d) self-selected distance aiming to attain maximum impact. The selected strength and power variables were as follows: maximal dynamic strength in bench press and squat-machine, squat and countermovement jump height, mean propulsive power in bench throw and jump squat, and mean propulsive velocity in jump squat with 40% of BM. Upper- and lower-body power and maximal dynamic strength variables were positively correlated to punch acceleration in all conditions. Multiple regression analysis also revealed predictive variables: relative mean propulsive power in squat jump (W·kg-1), and maximal dynamic strength 1 repetition maximum in both bench press and squat-machine exercises. An impact-oriented instruction and a self-selected distance to start the movement seem to be crucial to reach the highest acceleration during punching execution. This investigation, while demonstrating strong correlations between punching acceleration and strength-power variables, also provides important information for coaches, especially for designing better training strategies to improve punching speed.

  6. The surface layer of pharmaceutical compacts: the role of the punch surface and its impact on the mechanical properties of the compacts.

    PubMed

    Mazel, V; Busignies, V; Diarra, H; Reiche, I; Tchoreloff, P

    2013-02-14

    During pharmaceutical compaction, the interaction between the punch and the powder determines the formation and the aspect of the surface of the compact. In industry, the properties of the punch surface, which play a key role in this interaction, are sometimes changed by fixing an intermediate layer onto the punch to prevent sticking problems. In this article, the case of a polymer insert layer was studied. Firstly, sugar spheres were compacted with and without the polymer insert fixed onto the punches. After compaction with uncovered punches, the surface particles, which had been subjected to high deformation, were flattened on one side. However, it was observed, using confocal X-ray microfluorescence, that this kind of deformation was limited to the surface and that the bulk particles, which underwent a more isotropic deformation, still exhibited an approximately round shape. Secondly, the influence of the surface structure on the mechanical properties of the compacts was studied. The indentation hardness and the tensile strength of compacts of microcrystalline cellulose (MCC) and anhydrous calcium phosphate (aCP) were studied. No differences were found for the compacts of MCC produced with the two kinds of punches, but the compacts of aCP obtained with uncovered punches presented a higher hardness and a higher tensile strength than those obtained with covered punches.

  7. Fluorescence guidance during stereotactic biopsy

    NASA Astrophysics Data System (ADS)

    Stepp, Herbert; Beyer, Wolfgang; Brucker, David; Ehrhardt, Andre; Fischer, Stefan; Goebel, Werner; Goetz, Marcus; Guenther, Bettina; Hennig, Georg; Herms, Jochen; Irion, Klaus-Martin; Johansson, Ann; Kienast, Yvonne; Kniebuehler, Gesa; Li, Pan; Ruehm, Adrian; Sandner, Sabine

    2012-02-01

    Objective: When a stereotactic biopsy is taken to enable histopathological diagnosis of a suspected brain tumor, it is essential to i) do this safely, that is not injure a major blood vessel and ii) to obtain relevant vital material from the tumor. We are investigating the suitability of Indocyanine Green (ICG) fluorescence for blood vessel recognition and 5- Aminolevulinic acid (5-ALA) induced Protoporphyrin IX (PpIX) fluorescence for identification of proliferative brain tumor tissue. Methods: A fiber-optic endoscopic approach was studied to generate and detect both fluorescence signals. PpIX concentrations in brain tumors have been measured by chemical extraction. Preliminary equipment was studied in a mouse model. Results: PpIX-concentrations in glioblastoma tissue showed high inner- and inter-patient variability, but each patient out of 15 with interpretable data showed at least one sample with a PpIX-concentration exceeding 2.4 μmol/l, which is easily detectable by state-of-the-art fiberoptic fluorescence spectroscopy and imaging. The imaging fluoroscope with 30,000 pixels resolution could be introduced through a position controlled stereotactic needle. ICG-fluorescence from vessels with diameters >= 0.1 mm can be detected with a contrast of 2-2.5 against surrounding tissue. Conclusion: Fluorescence detection during stereotactic biopsy might increase safety and precision of the procedure significantly.

  8. DNA adducts in bronchial biopsies.

    PubMed

    Dunn, B P; Vedal, S; San, R H; Kwan, W F; Nelems, B; Enarson, D A; Stich, H F

    1991-06-19

    To investigate the feasibility of measuring DNA-carcinogen adducts in the lungs of non-surgical patients, endobronchial biopsies were obtained from 78 patients undergoing routine diagnostic bronchoscopy. Lung cancer was present in 37 (47%) of the patients. DNA was isolated from the tissues and analyzed by HPLC- or nuclease-PI-enriched 32P-postlabelling, using procedures selective for aromatic adducts. Chromatograms from all 28 current smokers showed a distinctive diagonal adduct zone which was present in only 24 of 40 ex-smokers and 4 of 10 lifetime non-smokers. Adduct levels and chromatographic patterns were similar in bronchial tissue from different lobes of the lung, in bronchial and alveolar tissue, and in tumor and non-tumor bronchial tissue taken from the same subject. Bronchial DNA adduct levels were strongly associated with cigarette smoking status and dropped rapidly after smoking ceased. Higher levels of DNA adducts seen in the lung-cancer patients were mainly due to cigarette smoking. Frequent alcohol intake was the only dietary factor associated with higher levels of bronchial DNA adducts. We conclude that the level of bronchial DNA adducts is strongly associated with cigarette-smoking history and with alcohol intake, but is not associated with lung cancer independently from its relation to smoking. The results indicate the feasibility of using 32P-postlabelling to detect and quantitate genetic damage in bronchial biopsy specimens.

  9. Basics of kidney biopsy: A nephrologist's perspective

    PubMed Central

    Agarwal, S. K.; Sethi, S.; Dinda, A. K.

    2013-01-01

    The introduction of the kidney biopsy is one of the major events in the history of nephrology. Primary indications of kidney biopsy are glomerular hematuria/proteinuria with or without renal dysfunction and unexplained renal failure. Kidney biopsy is usually performed in prone position but in certain situations, supine and lateral positions may be required. Biopsy needles have changed with times from Vim–Silverman needle to Tru-cut needle to spring-loaded automatic gun. The procedure has also changed from blind bedside kidney biopsy to ultrasound marking to real-time ultrasound guidance to rarely computerized tomography guidance and laparoscopic and open biopsy. In very specific situations, transjugular kidney biopsy may be required. Most of the centers do kidney biopsy on short 1-day admission, whereas some take it as an outdoor procedure. For critical interpretation of kidney biopsy, adequate sample and clinical information are mandatory. Tissue needs to be stained with multiple stains for delineation of various components of kidney tissue. Many consider that electron microscopy (EM) is a must for all kidney biopsies, but facilities for EM are limited even in big centers. Sophisticated tests such as immunohistochemistry and in-situ hybridization are useful adjuncts for definitive diagnosis in certain situations. PMID:23960337

  10. The influence of punching process on residual stress and magnetic domain structure of non-oriented silicon steel

    NASA Astrophysics Data System (ADS)

    Cao, Hongzhi; Hao, Linpo; Yi, Jingwen; Zhang, Xianglin; Luo, Zhonghan; Chen, Shenglin; Li, Rongfeng

    2016-05-01

    The main purpose of this paper is to investigate the influence of punching process on residual stress and magnetic domain structure. The residual stress in non-oriented silicon steel after punching process was measured by nanoindentation. The maximum depth was kept constant as 300 nm during nanoindentation. The material around indentation region exhibited no significant pile-up deformation. The calculation of residual stress was based on the Suresh theoretical model. Our experimental results show that residual compressive stress was generated around the sheared edge after punching. The width of residual stress affected zone by punching was around 0.4-0.5 mm. After annealing treatment, the residual stress was significantly decreased. Magnetic domain structure was observed according to the Bitter method. The un-annealed sample exhibited complicated domain patterns, and the widths of the magnetic domains varied between 3 μm and 8 μm. Most of the domain patterns of the annealed sample were 180°-domains and 90°-domains, and the widths of the domains decreased to 1-3 μm.

  11. Brain astrocytomas: biopsy, then irradiation.

    PubMed

    Lunsford, L D; Somaza, S; Kondziolka, D; Flickinger, J C

    1995-01-01

    We believe that every patient who has clinical symptoms and neurodiagnostic imaging signs suggesting a low-grade glial neoplasm should undergo early diagnosis and treatment. Observation is not warranted for a tumor that has a median survival of 5 years. The value of cytoreductive surgery for many patients has yet to be proven. It is incumbent on neurosurgeons who advocate this approach to show that this more aggressive treatment strategy is preferable to minimally invasive techniques, such as stereotactic biopsy followed by radiation therapy. Clearly, some patients who have a glial tumor require early cytoreductive surgery: those with mass effect and significant neurologic deficits. Otherwise, they will not be able to tolerate fractionated radiation therapy. Because the long-term survival rate is very poor, observation is not warranted in patients with suspected glial neoplasm. Early stereotactic biopsy immediately identifies those patients who, in fact, have more anaplastic tumors and a much worse prognosis. Such patients may benefit from early, aggressive treatments such as cytoreductive surgery, chemotherapy, and radiation. Applying this philosophy, we have achieved a median survival of more than 10 years in patients with astrocytoma. Most patients maintain a high KPS rating, and most do not require delayed cytoreductive surgery. Although we believe that the outcomes of future patients with astrocytomas will improve, we must establish whether such improvement is related to better therapeutic options, earlier recognition enabled by advanced neuroimaging, or the availability of corticosteroids (28, 30). We also believe that neurosurgeons and neuro-oncologists should stop arguing over whether cytoreductive surgery is warranted. For some patients it is, and for others it is not. This prolonged controversy indicates the basic impotence with which neurosurgeons approach glial tumors. Our energy and efforts should be devoted toward more concrete and positive goals in

  12. Galenic approaches in troubleshooting of glibenclamide tablet adhesion in compression machine punches.

    PubMed

    Boniatti, Janine; Pereira Cerqueira, Ana Lúcia; de Souza, Alexandre Carnevale; Drago Hoffmeister, Cristiane Rodrigues; da Costa, Maira Assis; Prado, Livia Deris; Tasso, Leandro; Antunes Rocha, Helvécio Vinícius

    2014-11-01

    This study aimed to examine the adhesion of glibenclamide 5 mg tablets to the tools of compression machines. This problem is not commonly reported in the literature, since it is considered as tacit knowledge. The starting point was the implementation of three technical alternatives: changing the parameters of compression, evaluating the humidity of the powder blend and the manufacturer of the lubricant magnesium stearate. The adhesion was directly related to the characteristics of magnesium stearate from different manufacturers, and the feasibility of evaluating powder flow characteristics by different techniques that are not routinely followed in various pharmaceutical companies. In vitro dissolution tests showed that the magnesium stearate manufacturer can influence on the dissolution profile of glibenclamide tablets. This study presented various aspects of tablet adhesion to compression machine punches. Troubleshooting approaches can be, most of times, conducted based on previous experience, or an experimental research needs to be implemented in order to have confident results.

  13. Galenic approaches in troubleshooting of glibenclamide tablet adhesion in compression machine punches

    PubMed Central

    Boniatti, Janine; Pereira Cerqueira, Ana Lúcia; de Souza, Alexandre Carnevale; Drago Hoffmeister, Cristiane Rodrigues; da Costa, Maira Assis; Prado, Livia Deris; Tasso, Leandro; Antunes Rocha, Helvécio Vinícius

    2013-01-01

    This study aimed to examine the adhesion of glibenclamide 5 mg tablets to the tools of compression machines. This problem is not commonly reported in the literature, since it is considered as tacit knowledge. The starting point was the implementation of three technical alternatives: changing the parameters of compression, evaluating the humidity of the powder blend and the manufacturer of the lubricant magnesium stearate. The adhesion was directly related to the characteristics of magnesium stearate from different manufacturers, and the feasibility of evaluating powder flow characteristics by different techniques that are not routinely followed in various pharmaceutical companies. In vitro dissolution tests showed that the magnesium stearate manufacturer can influence on the dissolution profile of glibenclamide tablets. This study presented various aspects of tablet adhesion to compression machine punches. Troubleshooting approaches can be, most of times, conducted based on previous experience, or an experimental research needs to be implemented in order to have confident results. PMID:25473333

  14. Punch stretching process monitoring using acoustic emission signal analysis. II - Application of frequency domain deconvolution

    NASA Technical Reports Server (NTRS)

    Liang, Steven Y.; Dornfeld, David A.; Nickerson, Jackson A.

    1987-01-01

    The coloring effect on the acoustic emission signal due to the frequency response of the data acquisition/processing instrumentation may bias the interpretation of AE signal characteristics. In this paper, a frequency domain deconvolution technique, which involves the identification of the instrumentation transfer functions and multiplication of the AE signal spectrum by the inverse of these system functions, has been carried out. In this way, the change in AE signal characteristics can be better interpreted as the result of the change in only the states of the process. Punch stretching process was used as an example to demonstrate the application of the technique. Results showed that, through the deconvolution, the frequency characteristics of AE signals generated during the stretching became more distinctive and can be more effectively used as tools for process monitoring.

  15. Development of small punch testing technique and its application to evaluation of mechanical properties degradation

    SciTech Connect

    Kameda, J.

    1993-10-01

    The present paper summarizes a small punch (SP) testing technique developed and its application to mechanical properties characterization. It has been clearly shown on ferritic alloys that the SP test was evaluate the intergranular embrittling potency of segregated solute, such as P, Sn and Sb causing temper embrittlement, and the effects of neutron irradiation and post-irradiation annealing, giving rise to changes in the hardness and intergranular solute segregation, on the fracture properties in terms of the ductile-brittle transition temperature (DBTT). A linear relation of the DBTT determined by the SP test to that by Charpy V-notched tests has been theoretically and experimentally established. In Al alloy substrates coated with amorphous and overlaying ceramics, moreover, the global and local fracture properties were well characterized by the SP test together with acoustic emission techniques.

  16. Galenic approaches in troubleshooting of glibenclamide tablet adhesion in compression machine punches.

    PubMed

    Boniatti, Janine; Pereira Cerqueira, Ana Lúcia; de Souza, Alexandre Carnevale; Drago Hoffmeister, Cristiane Rodrigues; da Costa, Maira Assis; Prado, Livia Deris; Tasso, Leandro; Antunes Rocha, Helvécio Vinícius

    2014-11-01

    This study aimed to examine the adhesion of glibenclamide 5 mg tablets to the tools of compression machines. This problem is not commonly reported in the literature, since it is considered as tacit knowledge. The starting point was the implementation of three technical alternatives: changing the parameters of compression, evaluating the humidity of the powder blend and the manufacturer of the lubricant magnesium stearate. The adhesion was directly related to the characteristics of magnesium stearate from different manufacturers, and the feasibility of evaluating powder flow characteristics by different techniques that are not routinely followed in various pharmaceutical companies. In vitro dissolution tests showed that the magnesium stearate manufacturer can influence on the dissolution profile of glibenclamide tablets. This study presented various aspects of tablet adhesion to compression machine punches. Troubleshooting approaches can be, most of times, conducted based on previous experience, or an experimental research needs to be implemented in order to have confident results. PMID:25473333

  17. Stress intensity factors in a cracked infinite elastic wedge loaded by a rigid punch

    NASA Technical Reports Server (NTRS)

    Erdogan, F.; Civelek, M. B.

    1978-01-01

    A plane elastic wedge-shaped solid was split through the application of a rigid punch. It was assumed that the coefficient of friction on the the contact area was constant, and the problem had a plane of symmetry with respect to loading and geometry, with the crack in the plane of symmetry. The problem was formulated in terms of a system of integral equations with the contact stress and the derivative of the crack surface displacement as the unknown functions. The solution was obtained for an internal crack and for an edge crack. The results include primarily the stress intensity factors at the crack tips, and the measure of the stress singularity at the wedge apex, and at the end points of the contact area.

  18. Image-Guided Adrenal and Renal Biopsy

    PubMed Central

    Sharma, Karun V.; Venkatesan, Aradhana M.; Swerdlow, Daniel; DaSilva, Daniel; Beck, Avi; Jain, Nidhi; Wood, Bradford J.

    2010-01-01

    Image-guided biopsy is a safe and well-established technique that is familiar to most interventional radiologists (IRs). Improvements in image-guidance, biopsy tools and biopsy techniques now routinely allow for safe biopsy of renal and adrenal lesions which traditionally were considered difficult to reach or technically challenging. Image-guided biopsy is used to establish the definitive tissue diagnosis in adrenal mass lesions that can not be fully characterized with imaging or laboratory tests alone. It is also used to establish definitive diagnosis in some cases of renal parenchymal disease and has an expanding role in diagnosis and characterization of renal masses prior to treatment. Although basic principles and techniques for image-guided needle biopsy are similar regardless of organ, this paper will highlight some technical considerations, indications and complications which are unique to the adrenal gland and kidney because of their anatomic location and physiologic features. PMID:20540919

  19. Parotid gland biopsy for investigation of xerostomia.

    PubMed

    Ferguson, J W; Edwards, J L; Christmas, P I; Ferguson, M M

    1990-08-01

    A technique is described for biopsy of the parotid salivary gland under local anaesthesia, which has been undertaken for a series of 59 patients who presented with suspected inflammatory exocrinopathy. The procedure is reliable and is associated with negligible postoperative discomfort. The advantages of the technique suggest that parotid gland biopsy is an acceptable alternative to conventional lower lip biopsy of minor salivary glands in the investigation of xerostomia.

  20. Photoacoustic biopsy: a feasibility study

    NASA Astrophysics Data System (ADS)

    Xu, Guan; Tomlins, Scott A.; Siddiqui, Javed; Davis, Mandy A.; Kunju, Lakshmi P.; Wei, John T.; Wang, Xueding

    2015-03-01

    Photoacoustic (PA) measurements encode the information associated with both physical microstructures and chemical contents in biological tissues. A two-dimensional physio-chemical spectrogram (PCS) can be formulated by combining the power spectra of PA signals acquired at a series of optical wavelengths. The analysis of PCS, or namely PA physio-chemical analysis (PAPCA), enables the quantification of the concentrations and the spatial distributions of a variety of chemical components in the tissue. The chemical components and their distribution are the two major features observed in the biopsy procedures which have been regarded as the gold standard of the diagnosis of many diseases. Taking non-alcoholic fatty liver disease and prostate cancer for example, this study investigates the feasibility of PAPCA in characterizing the histopathological changes in the diseased conditions in biological tissue. A catheter based setup facilitating measurement in deep tissues was also proposed and tested.

  1. Tissue Microarray Technology for Molecular Applications: Investigation of Cross-Contamination between Tissue Samples Obtained from the Same Punching Device

    PubMed Central

    Vassella, Erik; Galván, José A.; Zlobec, Inti

    2015-01-01

    Background: Tissue microarray (TMA) technology allows rapid visualization of molecular markers by immunohistochemistry and in situ hybridization. In addition, TMA instrumentation has the potential to assist in other applications: punches taken from donor blocks can be placed directly into tubes and used for nucleic acid analysis by PCR approaches. However, the question of possible cross-contamination between samples punched with the same device has frequently been raised but never addressed. Methods: Two experiments were performed. (1) A block from mycobacterium tuberculosis (TB) positivetissue and a second from an uninfected patient were aligned side-by-side in an automated tissue microarrayer. Four 0.6 mm punches were cored from each sample and placed inside their corresponding tube. Between coring of each donor block, a mechanical cleaning step was performed by insertion of the puncher into a paraffin block. This sequence of coring and cleaning was repeated three times, alternating between positive and negative blocks. A fragment from the 6110 insertion sequence specific for mycobacterium tuberculosis was analyzed; (2) Four 0.6 mm punches were cored from three KRAS mutated colorectal cancer blocks, alternating with three different wild-type tissues using the same TMA instrument (sequence of coring: G12D, WT, G12V, WT, G13D and WT). Mechanical cleaning of the device between each donor block was made. Mutation analysis by pyrosequencing was carried out. This sequence of coring was repeated manually without any cleaning step between blocks. Results/Discussion: In both analyses, all alternating samples showed the expected result (samples 1, 3 and 5: positive or mutated, samples 2, 4 and 6: negative or wild-type). Similar results were obtained without cleaning step. These findings suggest that no cross-contamination of tissue samples occurs when donor blocks are punched using the same device, however a cleaning step is nonetheless recommended. Our result supports

  2. Reconstruction of large wounds using a combination of negative pressure wound therapy and punch grafting after excision of acral lentiginous melanoma on the foot.

    PubMed

    Seo, Jimyung; Kim, Jihee; Nam, Kyoung Ae; Zheng, Zhenlong; Oh, Byung Ho; Chung, Kee Yang

    2016-01-01

    Melanoma in darker-pigmented individuals often develops in an acral lentiginous fashion on the foot. After surgical removal of a tumor at this site, repair of the wound can be challenging. This is because there is an insufficient local skin pool and lack of mobility of the skin in this area. Moreover, functional aspects such as walking and weight bearing should be considered. We performed a combination treatment of negative pressure wound therapy (NPWT) and punch grafting on 15 patients, after wide excision of acral lentiginous melanomas on the foot, and compared these to 26 patients who underwent either secondary intention healing (SIH, n = 13) or NPWT (n = 13) alone. The punch grafting with NPWT group showed significantly shorter healing times than those of the other two groups. Evaluation of completely healed wounds using the Vancouver Burn Scar Assessment Scale revealed that the punch grafting group had mean values better, or comparable, to the SIH or NPWT group in four of the five scales (except pigmentation). As for complications, only one patient developed a wound infection after punch grafting. Further, by utilizing NPWT for fixation of punch grafts, it was possible to treat all subjects as outpatients after punch grafting. These results show that a combination treatment of NPWT and punch grafting is an excellent therapeutic option for post-wide excision wounds on the feet, with significantly shortened healing times and favorable cosmetic outcomes. PMID:26173565

  3. Adequate histologic sectioning of prostate needle biopsies.

    PubMed

    Bostwick, David G; Kahane, Hillel

    2013-08-01

    No standard method exists for sampling prostate needle biopsies, although most reports claim to embed 3 cores per block and obtain 3 slices from each block. This study was undertaken to determine the extent of histologic sectioning necessary for optimal examination of prostate biopsies. We prospectively compared the impact on cancer yield of submitting 1 biopsy core per cassette (biopsies from January 2010) with 3 cores per cassette (biopsies from August 2010) from a large national reference laboratory. Between 6 and 12 slices were obtained with the former 1-core method, resulting in 3 to 6 slices being placed on each of 2 slides; for the latter 3-core method, a limit of 6 slices was obtained, resulting in 3 slices being place on each of 2 slides. A total of 6708 sets of 12 to 18 core biopsies were studied, including 3509 biopsy sets from the 1-biopsy-core-per-cassette group (January 2010) and 3199 biopsy sets from the 3-biopsy-cores-percassette group (August 2010). The yield of diagnoses was classified as benign, atypical small acinar proliferation, high-grade prostatic intraepithelial neoplasia, and cancer and was similar with the 2 methods: 46.2%, 8.2%, 4.5%, and 41.1% and 46.7%, 6.3%, 4.4%, and 42.6%, respectively (P = .02). Submission of 1 core or 3 cores per cassette had no effect on the yield of atypical small acinar proliferation, prostatic intraepithelial neoplasia, or cancer in prostate needle biopsies. Consequently, we recommend submission of 3 cores per cassette to minimize labor and cost of processing. PMID:23764163

  4. Study on the effect of punched holes on flow structure and heat transfer of the plain fin with multi-row delta winglets

    NASA Astrophysics Data System (ADS)

    Tian, Liting; Liu, Bin; Min, Chunhua; Wang, Jin; He, Yaling

    2015-11-01

    Three dimensional numerical simulations are performed to investigate the flow and heat transfer characteristics of the plain fin with multi-row delta winglets punched out from the fin. The Reynolds number based on the tube outside diameter varies from 360 to 1440. The effects of punched holes and their orientations on flow structure and heat transfer are numerically studied. Results show that a down-wash flow is formed through the hole punched at the windward side, which has little influence on the longitudinal vortices in the main flow, and a longitudinal main vortex is formed behind each delta winglet. An up-wash flow is formed through the hole punched at the leeward side, the up-wash flow impinges the longitudinal vortices generated by the delta winglet, and then a counter-rotating pair of main vortices is generated behind each delta winglet. The windward punched holes have little effect on the flow friction and heat transfer of the plain fin with delta winglets, while the leeward punched holes deteriorate the heat transfer and decrease the flow friction of the fin channel, the Nusselt number decreases by 3.5-5.0 % with a corresponding decrease of 3.9-4.8 % in the friction factor. The effect of the punched holes on the heat transfer of the fin can be well explained by the field synergy principle. The overall analysis of the thermal performance is performed for all fin configurations, including the slit fins and the wavy fins with one-row delta winglets, the plain fin with the windward punched delta winglets shows the better thermal performance than one with the leeward punched delta winglets.

  5. A Comparison of Vertical and Transverse Sections in the Histological Diagnosis of Alopecia Areata Scalp Biopsy Specimens

    PubMed Central

    Singh, Kanika; Sharma, Sonal; Singh, Usha Rani; Bhattacharya, Sambit Nath

    2016-01-01

    Context: Both vertical and transverse sections are used for the diagnosis of alopecia areata. However when a single biopsy is submitted the pathologist has to decide which type is better. Aims: To compare the diagnostic histological features in vertical and transverse sections in alopecia areata scalp biopsy specimens. Settings and Design: Tertiary Care Hospital. Comparative Study. Materials and Methods: A total of 30 patients were enrolled in the study. Two four mm punch biopsy were taken. One was used to take vertical sections and the other for transverse section and histological features of alopecia areata noted in both. Statistical Analysis Used: Chi-square test, percentage. Results: Diagnosis of alopecia areata could be made in 30 (100%) cases in transverse sections and 28 cases (93.3%) in vertical sections. The number of hair follicles available for evaluation was more in the transverse section. Nanogen follicles and miniaturization of follicles were better visualized in the transverse sections. However the catagen and telogen follicles were noted in both vertical and transverse sections but the number and the ratio of anagen and telogen hair follicles could be better assessed in the transverse sections. Presence of peribulbar lymphocytic infiltrate, eosinophils and pigment casts were noted in both transverse and vertical sections. Conclusions: Transverse sections provide a better assessment of the histological features of alopecia areata than vertical sections and thus should be preferred. PMID:27625562

  6. 20 CFR 718.106 - Autopsy; biopsy.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Autopsy; biopsy. 718.106 Section 718.106 Employees' Benefits EMPLOYMENT STANDARDS ADMINISTRATION, DEPARTMENT OF LABOR FEDERAL COAL MINE HEALTH AND... pneumoconiosis. However, where positive findings are obtained on biopsy, the results will constitute evidence...

  7. Transjugular liver biopsy: indications, technique and results.

    PubMed

    Dohan, A; Guerrache, Y; Boudiaf, M; Gavini, J-P; Kaci, R; Soyer, P

    2014-01-01

    Transjugular liver biopsy is a safe, effective and well-tolerated technique to obtain liver tissue specimens in patients with diffuse liver disease associated with severe coagulopathies or massive ascites. Transjugular liver biopsy is almost always feasible. The use of ultrasonographic guidance for percutaneous puncture of the right internal jugular vein is recommended to decrease the incidence of local cervical minor complications. Semiautomated biopsy devices are very effective in obtaining optimal tissue samples for a precise and definite histological diagnosis with a very low rate of complication. The relative limitations of transjugular liver biopsy are the cost, the radiation dose given to the patient, the increased procedure time by comparison with the more common percutaneous liver biopsy, and the need of a well-trained interventional radiologist. PMID:24007769

  8. Biopsy needle detection in transrectal ultrasound.

    PubMed

    Ayvaci, Alper; Yan, Pingkun; Xu, Sheng; Soatto, Stefano; Kruecker, Jochen

    2011-01-01

    Using the fusion of pre-operative MRI and real time intra-procedural transrectal ultrasound (TRUS) to guide prostate biopsy has been shown as a very promising approach to yield better clinical outcome than the routinely performed TRUS only guided biopsy. In several situations of the MRI/TRUS fusion guided biopsy, it is important to know the exact location of the deployed biopsy needle, which is imaged in the TRUS video. In this paper, we present a method to automatically detect and segment the biopsy needle in TRUS. To achieve this goal, we propose to combine information from multiple resources, including ultrasound probe stability, TRUS video background model, and the prior knowledge of needle orientation and position. The proposed algorithm was tested on TRUS video sequences which have in total more than 25,000 frames. The needle deployments were successfully detected and segmented in the sequences with high accuracy and low false-positive detection rate.

  9. Open lung biopsy in immunocompromised patients.

    PubMed

    McKenna, R J; Mountain, C F; McMurtrey, M J

    1984-11-01

    Increased use of open lung biopsy in the search for a treatable etiology of acute interstitial pneumonitis (AIP) in immunocompromised patients is based on the assumption that examination and cultures from biopsy specimens will yield significant information leading to beneficial treatment of the condition. To assess the true impact of the results of open lung biopsy on the subsequent treatment and outcome in such patients, a retrospective study was done of 64 consecutive patients undergoing the procedure in a recent five-year period. When open lung biopsy was performed for the diagnosis of AIP in immunocompromised patients after empiric broad spectrum treatment failed, it rarely missed a specific, treatable etiology, if present. However, the results from open lung biopsy infrequently lead to a change in the treatment that improves the patient's clinical course.

  10. Delayed culture of Leishmania in skin biopsies.

    PubMed

    Dedet, J P; Pratlong, F; Pradinaud, R; Moreau, B

    1999-01-01

    Between January 1997 and October 1998, 16 skin biopsies collected from 13 patients with cutaneous leishmaniasis in French Guiana were inoculated in culture medium after travel for 3-17 days from the place of biopsy to the culture laboratory in France. Each biopsy fragment was introduced near the flame of a Bunsen burner into the transport medium (RPMI medium supplemented with 10% fetal calf serum) which was maintained at ambient temperature during postal delivery to France. In France the biopsies were ground in sterile saline before being inoculated into NNN culture tubes. The cultures were incubated at 25 degrees C and subcultured every week until the 5th week. The cultures were positive in 9 cases, remained negative in 4, and were contaminated in 3 cases. Positive results were obtained at all seasons and for 3 different Leishmania species. The study indicates that delayed culture can yield useful results from biopsies taken in field conditions.

  11. Transplant biopsy beyond light microscopy.

    PubMed

    Adam, Benjamin; Mengel, Michael

    2015-01-01

    Despite its long-standing status as the diagnostic "gold standard", the renal transplant biopsy is limited by a fundamental dependence on descriptive, empirically-derived consensus classification. The recent shift towards personalized medicine has resulted in an increased demand for precise, mechanism-based diagnoses, which is not fully met by the contemporary transplantation pathology standard of care. The expectation is that molecular techniques will provide novel pathogenetic insights that will allow for the identification of more accurate diagnostic, prognostic, and therapeutic targets. Here we review the current state of molecular renal transplantation pathology. Despite significant research activity and progress within the field, routine adoption of clinical molecular testing has not yet been achieved. The recent development of novel molecular platforms suitable for use with formalin-fixed paraffin-embedded tissue will offer potential solution for the major barriers to implementation. The recent incorporation of molecular diagnostic criteria into the 2013 Banff classification is a reflection of progress made and future directions in the area of molecular transplantation pathology. Transcripts related to endothelial injury and NK cell activation have consistently been shown to be associated with antibody-mediated rejection. Prospective multicenter validation and implementation of molecular diagnostics for major entities remains an unmet clinical need in transplantation. It is expected that an integrated system of transplantation pathology diagnosis comprising molecular, morphological, serological, and clinical variables will ultimately provide the greatest diagnostic precision. PMID:26249165

  12. Changing Dermatopathology Protocols for Processing Small Skin Biopsies: Decreases in Slide Quantity Does Not Affect Patient Care and Allows for Optimal Efficiency.

    PubMed

    Mudaliar, Kumaran; Speiser, Jodi; Hutchens, Kelli A

    2016-06-01

    In dermatopathology, no standard protocol exists for processing small biopsy specimens. In our original protocol, 2 routine initial slides per biopsy were prepared. For 1003 biopsies, we noted how often the second slide helped in diagnosis or eliminated the need for additional deeper sections. After obtaining these data, we switched to processing only 1 initial slide (new protocol) and again evaluated 1003 biopsies. During the original protocol, the second slide never helped to make a diagnosis that was not apparent on the first slide. When deeper sections were ordered (10.4% of cases), they helped in the diagnosis 34.6% of the time. In the new protocol, deeper sections were ordered in 15.9% of cases and helped in the diagnosis 32.7% of the time when ordered. Comparing rates of deeper sections ordered showed no significant difference for benign, inflammatory/reactive, and premalignant/malignant groups (P > 0.1). However, there was a significant increase in deeper sections ordered for melanocytic lesions from 16.9% to 32.3% (P < 0.05). Also, a significantly greater percentage of punch biopsies (31.5% and 42.0% in the respective protocols) required deeper sections than shave biopsies (7.4% and 12.6% in the respective protocols). Switching protocols, the estimated annual cost savings is $2890. The majority of cases at our institution are properly diagnosed using only 1 slide. From our study findings, we conclude that 1 slide preparation for small biopsies is the best practice for our institution and one that does not affect diagnostic accuracy, reduces costs, and helps in effective time management. PMID:27101126

  13. Utilization trends and positive biopsy rates for prostate biopsies in the United States: 2005 to 2011.

    PubMed

    Kapoor, Deepak A; Bostwick, David G; Mendrinos, Savvas E; Anderson, Ann E; Olsson, Carl A

    2013-01-01

    This article assesses the positive biopsy rate and core sampling pattern in patients undergoing needle biopsy of the prostate in the United States at a national reference laboratory (NRL) and anatomic pathology laboratories integrated into urology group practices, and analyzes the relationship between positive biopsy rates and the number of specimen vials per biopsy. For the years 2005 to 2011 we collected pathology data from an NRL, including number of urologists and urology practices referring samples, total specimen vials submitted for prostate biopsies, and final pathologic diagnosis for each case. The diagnoses were categorized as benign, malignant, prostatic intraepithelial neoplasia, or atypical small acinar proliferation. Over the same period, similar data were gathered from urology practices with in-house laboratories performing global pathology services (urology practice laboratories; UPLs) as identified by a survey of members of the Large Urology Group Practice Association. For each year studied, positive biopsy rate and number of specimen vials per biopsy were calculated in aggregate and separately for each site of service. From 2005 to 2011, 437,937 biopsies were submitted in > 4.23 million vials (9.4 specimen vials/biopsy); overall positive biopsy rate was 40.3%-this was identical at both the NRL and UPL (P = .97). Nationally, the number of specimen vials per biopsy increased sharply from a mean of 8.8 during 2005 to 2008 to a mean of 10.3 from 2009 to 2011 (difference, 1.5 specimen vials/biopsy; P = .03). For the most recent 3-year period (2009-2011), the difference of 0.6 specimen vials per biopsy between the NRL (10.0) and UPL (10.6) was not significant (P = 0.08). Positive biopsy rate correlated strongly (P < .01) with number of specimen vials per biopsy. The positive prostate biopsy rate is 40.3% and is identical across sites of service. Although there was a national trend toward increased specimen vials per biopsy from 2005 to 2011, from 2009 to

  14. Utilization Trends and Positive Biopsy Rates for Prostate Biopsies in the United States: 2005 to 2011

    PubMed Central

    Kapoor, Deepak A; Bostwick, David G; Mendrinos, Savvas E; Anderson, Ann E; Olsson, Carl A

    2013-01-01

    This article assesses the positive biopsy rate and core sampling pattern in patients undergoing needle biopsy of the prostate in the United States at a national reference laboratory (NRL) and anatomic pathology laboratories integrated into urology group practices, and analyzes the relationship between positive biopsy rates and the number of specimen vials per biopsy. For the years 2005 to 2011 we collected pathology data from an NRL, including number of urologists and urology practices referring samples, total specimen vials submitted for prostate biopsies, and final pathologic diagnosis for each case. The diagnoses were categorized as benign, malignant, prostatic intraepithelial neoplasia, or atypical small acinar proliferation. Over the same period, similar data were gathered from urology practices with in-house laboratories performing global pathology services (urology practice laboratories; UPLs) as identified by a survey of members of the Large Urology Group Practice Association. For each year studied, positive biopsy rate and number of specimen vials per biopsy were calculated in aggregate and separately for each site of service. From 2005 to 2011, 437,937 biopsies were submitted in > 4.23 million vials (9.4 specimen vials/biopsy); overall positive biopsy rate was 40.3%-this was identical at both the NRL and UPL (P = .97). Nationally, the number of specimen vials per biopsy increased sharply from a mean of 8.8 during 2005 to 2008 to a mean of 10.3 from 2009 to 2011 (difference, 1.5 specimen vials/biopsy; P = .03). For the most recent 3-year period (2009–2011), the difference of 0.6 specimen vials per biopsy between the NRL (10.0) and UPL (10.6) was not significant (P = 0.08). Positive biopsy rate correlated strongly (P < .01) with number of specimen vials per biopsy. The positive prostate biopsy rate is 40.3% and is identical across sites of service. Although there was a national trend toward increased specimen vials per biopsy from 2005 to 2011, from 2009

  15. From micro- to nano-scale molding of metals : size effect during molding of single crystal Al with rectangular strip punches.

    SciTech Connect

    Chen, K.; Meng, W. J.; Mei, F.; Hiller, J.; Miller, D. J.

    2011-02-01

    A single crystal Al specimen was molded at room temperature with long, rectangular, strip diamond punches. Quantitative molding response curves were obtained at a series of punch widths, ranging from 5 {micro}m to 550 nm. A significant size effect was observed, manifesting itself in terms of significantly increasing characteristic molding pressure as the punch width decreases to 1.5 {micro}m and below. A detailed comparison of the present strip punch molding results was made with Berkovich pyramidal indentation on the same single crystal Al specimen. The comparison reveals distinctly different dependence of the characteristic pressure on corresponding characteristic length. The present results show the feasibility of micro-/nano-scale compression molding as a micro-/nano-fabrication technique, and offer an experimental test case for size-dependent plasticity theories.

  16. Prevention of sepsis prior to prostate biopsy

    PubMed Central

    Toner, Liam; Bolton, Damien M

    2016-01-01

    Purpose Urosepsis is the most feared complication of transrectal prostate biopsy. The incidence may be increasing from <1% to 2%–3% in contemporary series. Historically, fluoroquinolones have been effective antibiotic prophylaxis to prevent infective complications but antibiotic resistance is increasing. The increase in antibiotic resistance may contribute to reported increases in urosepsis and hospitalization after transrectal biopsy. This article will review other methods clinicians may employ to reduce the incidence of infective complications after prostate biopsy. Materials and Methods A systematic review of the literature was conducted using literature databases PubMed and Ovid MEDLINE in August 2015 in accordance with the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-analyses) criteria. Results Effective strategies to reduce infective complications after transrectal prostate biopsy include augmented prophylaxis with other antibiotics, rectal swab culture directed antibiotic prophylaxis or a transperineal biopsy approach. Needle disinfection, minimizing the number of biopsy needles and rectal disinfectants may also be of use. These methods may be of particular utility in patients with risk factors for developing urosepsis such as recent antibiotic use and overseas travel. Conclusions The scientific literature describes various techniques designed to reduce infective complications caused by prostate biopsy. Clinicians should consider incorporating these novel techniques into their contemporary practice. PMID:26981590

  17. Modified connective tissue punch technique to increase the vestibular/buccal keratinized tissue on flapless implant surgery: a case series.

    PubMed

    Andreasi Bassi, M; Andrisani, C; Lopez, M A; Gaudio, R M; Lombardo, L; Lauritano, D

    2016-01-01

    The aim of this article is to show a simple and predictable technique to enhance both the vestibular/buccal (V/B) gingival thickness (GT) and keratinized tissue width (KTW) improving the soft-tissue profile after flapless implant placement. The technique proposed was named Modified Connective Tissue Punch (MCTP). Fourteen patients (6 men and 8 women) aged between 35 and 69 years (mean value 48.07±13.023 years) were enrolled in this case series. Seventeen implant sites were submitted to flapless procedure. The connective punch (CP) was harvested with a motor-driven circular tissue punch and then a full-split dissection was executed, in order to create a deep pouch, beyond the mucogingival junction, on the V/B side. In this recipient site the CP was placed. The normal flapless surgical protocol was used; implants were inserted and covered with transgingival healing cap screws. GT and KTW were measured: both immediately before and after surgery; at the time of the prosthetic finalization (3-4months, respectively, for mandible and maxilla); 1 year post surgery follow-up. GT was measured at 1 mm, 2 mm and 5 mm on the V/B side, from the outline of the punch. Both KTW and GT at 1 and 2 mm can be effectively increased, while no significant effects for GT at 5 mm can be expected from this technique. Furthermore, the mean values of KTW and GT at 1 mm and 2 mm show significant increases at 3-4 months post-operative, while no further significant increments are shown at 1 year post-operative follow-up. The Authors recommend the use of the MCTP technique to reduce the number of aesthetic complications and soft tissue defects in flapless implant surgery. Longer follow-ups are needed to evaluate the stability of peri-implant tissues over time. PMID:27469545

  18. Modified connective tissue punch technique to increase the vestibular/buccal keratinized tissue on flapless implant surgery: a case series.

    PubMed

    Andreasi Bassi, M; Andrisani, C; Lopez, M A; Gaudio, R M; Lombardo, L; Lauritano, D

    2016-01-01

    The aim of this article is to show a simple and predictable technique to enhance both the vestibular/buccal (V/B) gingival thickness (GT) and keratinized tissue width (KTW) improving the soft-tissue profile after flapless implant placement. The technique proposed was named Modified Connective Tissue Punch (MCTP). Fourteen patients (6 men and 8 women) aged between 35 and 69 years (mean value 48.07±13.023 years) were enrolled in this case series. Seventeen implant sites were submitted to flapless procedure. The connective punch (CP) was harvested with a motor-driven circular tissue punch and then a full-split dissection was executed, in order to create a deep pouch, beyond the mucogingival junction, on the V/B side. In this recipient site the CP was placed. The normal flapless surgical protocol was used; implants were inserted and covered with transgingival healing cap screws. GT and KTW were measured: both immediately before and after surgery; at the time of the prosthetic finalization (3-4months, respectively, for mandible and maxilla); 1 year post surgery follow-up. GT was measured at 1 mm, 2 mm and 5 mm on the V/B side, from the outline of the punch. Both KTW and GT at 1 and 2 mm can be effectively increased, while no significant effects for GT at 5 mm can be expected from this technique. Furthermore, the mean values of KTW and GT at 1 mm and 2 mm show significant increases at 3-4 months post-operative, while no further significant increments are shown at 1 year post-operative follow-up. The Authors recommend the use of the MCTP technique to reduce the number of aesthetic complications and soft tissue defects in flapless implant surgery. Longer follow-ups are needed to evaluate the stability of peri-implant tissues over time.

  19. PET-Based Percutaneous Needle Biopsy.

    PubMed

    El-Haddad, Ghassan

    2016-07-01

    PET can be used to guide percutaneous needle biopsy to the most metabolic lesion, improving diagnostic yield. PET biopsy guidance can be performed using visual or software coregistration, electromagnetic needle tracking, cone-beam computed tomography (CT), and intraprocedural PET/CT guidance. PET/CT-guided biopsies allow the sampling of lesions that may not be clearly visible on anatomic imaging, or of lesions that are morphologically normal. PET can identify suspicious locations within complex tumors that are most likely to contain important diagnostic and prognostic information. PMID:27321036

  20. Study of Hot Tearing During Steel Solidification Through Ingot Punching Test and Its Numerical Simulation

    NASA Astrophysics Data System (ADS)

    Koshikawa, Takao; Bellet, Michel; Gandin, Charles-André; Yamamura, Hideaki; Bobadilla, Manuel

    2016-08-01

    Experimental and numerical studies of hot tearing formation in steel are reported. On the one hand, an ingot punching test is presented. It consists in the application of a deformation at the surface of a solidifying 450 kg steel ingot. The experimental parameters are the displacement of the pressing tool, together with its velocity, leading to variations of a global strain rate. On the other hand, three-dimensional finite element thermomechanical modeling of the test is used. The time evolution of the strain tensor serves to compute an index to evaluate the susceptibility to create hot tears. It is based on the integration of a hot tearing criterion (HTC) that compares the local accumulation of strain with the expression of a critical value proposed in the literature. The main variable of the criterion is the brittleness temperature range (BTR) that refers to the solidification interval during which strain accumulates and creates hot cracks or tears. Detailed comparison of the simulation results with the measurements reveals the importance of the BTR for the prediction as well as excellent capabilities of the HTC to predict the formation of hot tears.

  1. Hemodynamic Performance of a New Punched Stent Strut: A Numerical Study.

    PubMed

    Xue, Yan; Liu, Xiao; Sun, Anqiang; Zhang, Peng; Fan, Yubo; Deng, Xiaoyan

    2016-07-01

    Local flow disturbance by arterial stent struts has been shown to play an important role in stent thrombosis. To reduce the local flow disturbance near a stent strut, we proposed a new concept of stent design with small holes in the stent struts. The present study evaluated the new design numerically by comparing it with the traditional stent in terms of local hemodynamic parameters such as flow velocity, flow recirculation area, time-averaged wall shear stress (TAWSS), oscillating shear index (OSI), and relative residence time (RRT). The results demonstrated that when compared with the traditional strut, the new design could significantly enhance flow velocity and reduce the flow recirculation zone in the vicinity of the strut. Moreover, the new design would significantly elevate TAWSS and remarkably reduce OSI and RRT along the host arterial wall. In conclusion, the new design of stent struts with punched holes is advantageous over the traditional one in the aspect of improving local hemodynamics, which may reduce thrombosis formation and promote re-endothelialization after stenting.

  2. Reconciling species-level vs plastic responses of evergreen leaf structure to light gradients: shade leaves punch above their weight.

    PubMed

    Lusk, Christopher H; Onoda, Yusuke; Kooyman, Robert; Gutiérrez-Girón, Alba

    2010-04-01

    *When grown in a common light environment, the leaves of shade-tolerant evergreen trees have a larger leaf mass per unit area (LMA) than their light-demanding counterparts, associated with differences in lifespan. Yet plastic responses of LMA run counter to this pattern: shade leaves have smaller LMA than sun leaves, despite often living longer. *We measured LMA and cell wall content, and conducted punch and shear tests, on sun and shade leaves of 13 rainforest evergreens of differing shade tolerance, in order to understand adaptation vs plastic responses of leaf structure and biomechanics to shade. *Species shade tolerance and leaf mechanical properties correlated better with cell wall mass per unit area than with LMA. Growth light environment had less effect on leaf mechanics than on LMA: shade leaves had, on average, 40% lower LMA than sun leaves, but differences in work-to-shear, and especially force-to-punch, were smaller. This was associated with a slightly larger cell wall fraction in shade leaves. *The persistence of shade leaves might reflect unattractiveness to herbivores because they yield smaller benefits (cell contents per area) per unit fracture force than sun leaves. In forest trees, cell wall fraction and force-to-punch are more robust correlates of species light requirements than LMA.

  3. Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid

    MedlinePlus

    ... Index A-Z Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid An ultrasound-guided thyroid biopsy ... Thyroid? What is Ultrasound-Guided Fine Needle Aspiration Biopsy of the Thyroid? During a fine needle aspiration ...

  4. Magnetic Resonance (MR)-Guided Breast Biopsy

    MedlinePlus

    ... the breast are often detected by physical examination, mammography, or other imaging studies. However, it is not ... considered if the lesion can be seen on mammography or on ultrasound , where the biopsy can be ...

  5. Magnetic Resonance Imaging-Guided Osseous Biopsy in Children With Chronic Recurrent Multifocal Osteomyelitis

    SciTech Connect

    Fritz, Jan; Tzaribachev, Nikolay; Thomas, Christoph; Wehrmann, Manfred; Horger, Marius S.; Carrino, John A.; Koenig, Claudius W.; Pereira, Philippe L.

    2012-02-15

    Purpose: To report the safety and diagnostic performance of magnetic resonance (MRI)-guided core biopsy of osseous lesions in children with chronic recurrent multifocal osteomyelitis (CRMO) that were visible on MRI but were occult on radiography and computed tomography (CT). Materials and Methods: A retrospective analysis of MRI-guided osseous biopsy performed in seven children (four girls and three boys; mean age 13 years (range 11 to 14) with CRMO was performed. Indication for using MRI guidance was visibility of lesions by MRI only. MRI-guided procedures were performed with 0.2-Tesla (Magnetom Concerto; Siemens, Erlangen, Germany; n = 5) or 1.5-T (Magnetom Espree; Siemens; n = 2) open MRI systems. Core needle biopsy was obtained using an MRI-compatible 4-mm drill system. Conscious sedation or general anesthesia was used. Parameters evaluated were lesion visibility, technical success, procedure time, complications and microbiology, cytology, and histopathology findings. Results: Seven of seven (100%) targeted lesions were successfully visualized and sampled. All obtained specimens were sufficient for histopathological analysis. Length of time of the procedures was 77 min (range 64 to 107). No complications occurred. Histopathology showed no evidence of malignancy, which was confirmed at mean follow-up of 50 months (range 28 to 78). Chronic nonspecific inflammation characteristic for CRMO was present in four of seven (58%) patients, and edema with no inflammatory cells was found in three of seven (42%) patients. There was no evidence of infection in any patient. Conclusion: MRI-guided osseous biopsy is a safe and accurate technique for the diagnosis of pediatric CRMO lesions that are visible on MRI only.

  6. Analyses of Transient and Tertiary Small Punch Creep Deformation of 316LN Stainless Steel

    NASA Astrophysics Data System (ADS)

    Ganesh Kumar, J.; Ganesan, V.; Laha, K.

    2016-09-01

    Creep deformation behavior of 316LN stainless steel (SS) under small punch creep (SPC) and uniaxial creep test has been assessed and compared at 923 K (650 °C). The transient and tertiary creep deformation behaviors have been analyzed according to the equation proposed for SPC deflection, δ = δ0 + δ_{{T}} \\cdot (1 - {{e}}^{ - κ \\cdot t} ) + dot{δ }_{{s}} t + δ3 {{e}}^{{[ {φ ( {t - t_{{r}} } )} ]}} on the basis of Dobes and Cadek equation for uniaxial creep strain. Trends in the variations of (i) rate of exhaustion of transient creep ( κ) with steady-state deflection rate ( dot{δ }_{{s}} ) (ii) ` κ' with time to attain steady-state deflection rate, and (iii) initial creep deflection rate with steady-state deflection rate implied that transient SPC deformation obeyed first-order reaction rate theory. The rate of exhaustion of transient creep ( r') values that were determined from uniaxial creep tests were correlated with those obtained from SPC tests. Master curves representing transient creep deformation in both SPC and uniaxial creep tests have been derived and their near coincidence brings unique equivalence between both the test techniques. The relationships between (i) rate of acceleration of tertiary creep ( φ) and steady-state deflection rate, (ii) ` φ' and time spent in tertiary stage, and (iii) final creep deflection rate and steady-state deflection rate revealed that first-order reaction rate theory governed SPC deformation throughout the tertiary region also. Interrelationship between the transient, secondary, and tertiary creep parameters indicated that the same mechanism prevailed throughout the SPC deformation.

  7. The `One-Two Punch' of Alcoholism: Role of Central Amygdala Dynorphins / Kappa-Opioid Receptors

    PubMed Central

    Kissler, Jessica L.; Sirohi, Sunil; Reis, Daniel J.; Jansen, Heiko T.; Quock, Raymond M.; Smith, Daniel G.; Walker, Brendan M.

    2013-01-01

    Background The dynorphin (DYN)/κ-opioid receptor (KOR) system undergoes neuroadaptations following chronic alcohol exposure that promote excessive operant self-administration and negative affective-like states; however, the exact mechanisms are unknown. The present studies tested the hypothesis that an upregulated DYN/KOR system mediates excessive alcohol self-administration that occurs during withdrawal in alcohol-dependent rats by assessing DYN A peptide expression and KOR function, in combination with site-specific pharmacological manipulations. Methods Male Wistar rats were trained to self-administer alcohol using operant behavioral strategies and subjected to intermittent alcohol vapor- or air-exposure. Changes in self-administration were assessed by pharmacological challenges during acute withdrawal. In addition, 22-kHz ultrasonic vocalizations were utilized to measure negative affective-like states. Immunohistochemical techniques assessed DYN A peptide expression and [35S]GTPγS coupling assays were performed to assess KOR function. Results Alcohol-dependent rats displayed increased alcohol self-administration, negative affective-like behavior, DYN A-like immunoreactivity and KOR signaling in the amygdala compared to non-dependent controls. Site-specific infusions of a KOR antagonist selectively attenuated self-administration in dependent rats whereas, a MOR/DOR antagonist cocktail selectively reduced self-administration in non-dependent rats. A MOR antagonist/partial KOR agonist attenuated self-administration in both cohorts. Conclusion Increased DYN A and increased KOR signaling could set the stage for a `one-two punch' during withdrawal that drives excessive alcohol consumption in alcohol-dependence. Importantly, intra-CeA pharmacological challenges functionally confirmed a DYN/KOR system involvement in the escalated alcohol self-administration. Together, the DYN/KOR system is heavily dysregulated in alcohol dependence and contributes to the excessive

  8. [Prostate biopsy: Procedure in the clinical routine].

    PubMed

    Enzmann, T; Tokas, T; Korte, K; Ritter, M; Hammerer, P; Franzaring, L; Heynemann, H; Gottfried, H-W; Bertermann, H; Meyer-Schwickerath, M; Wirth, B; Pelzer, A; Loch, T

    2015-12-01

    Over the last decade there has been a 25% decrease in the mortality rates for prostate cancer. The reasons for this significant decrease are most likely associated with the application of urological screening tests. The main tools for early detection are currently increased public awareness of the disease, prostate-specific antigen (PSA) tests and transrectal ultrasound (TRUS) guided topographically assignable biopsy sampling. Together with the histopathological results these features provide essential information for risk stratification, diagnostics and therapy decisions. The evolution of prostate biopsy techniques as well as the use of PSA testing has led to an increased identification of asymptomatic men, where further clarification is necessary. Significant efforts and increased clinical research focus on determining the appropriate indications for a prostate biopsy and the optimal technique to achieve better detection rates. The most widely used imaging modality for the prostate is TRUS; however, there are no clearly defined standards for the clinical approach for each individual biopsy procedure, dealing with continuous technical optimization and in particular the developments in imaging. In this review the current principles, techniques, new approaches and instrumentation of prostate biopsy imaging control are presented within the framework of the structured educational approach. PMID:26704284

  9. Common Data Elements for Muscle Biopsy Reporting

    PubMed Central

    Dastgir, Jahannaz; Rutkowski, Anne; Alvarez, Rachel; Cossette, Stacy A.; Yan, Ke; Hoffmann, Raymond G.; Sewry, Caroline; Hayashi, Yukiko K.; Goebel, Hans-Hilmar; Bonnemann, Carsten; Lawlor, Michael W.

    2016-01-01

    Context There is no current standard among myopathologists for reporting muscle biopsy findings. The National Institute of Neurological Disorders and Stroke has recently launched a common data element (CDE) project to standardize neuromuscular data collected in clinical reports and to facilitate their use in research. Objective To develop a more-uniform, prospective reporting tool for muscle biopsies, incorporating the elements identified by the CDE project, in an effort to improve reporting and educational resources. Design The variation in current biopsy reporting practice was evaluated through a study of 51 muscle biopsy reports from self-reported diagnoses of genetically confirmed or undiagnosed muscle disease from the Congenital Muscle Disease International Registry. Two reviewers independently extracted data from deidentified reports and entered them into the revised CDE format to identify what was missing and whether or not information provided on the revised CDE report (complete/incomplete) could be successfully interpreted by a neuropathologist. Results Analysis of the data highlighted showed (1) inconsistent reporting of key clinical features from referring physicians, and (2) considerable variability in the reporting of pertinent positive and negative histologic findings by pathologists. Conclusions We propose a format for muscle-biopsy reporting that includes the elements in the CDE checklist and a brief narrative comment that interprets the data in support of a final interpretation. Such a format standardizes cataloging of pathologic findings across the spectrum of muscle diseases and serves emerging clinical care and research needs with the expansion of genetic-testing therapeutic trials. PMID:26132600

  10. Percutaneous Biopsy of Osteoid Osteomas Prior to Percutaneous Treatment Using Two Different Biopsy Needles

    SciTech Connect

    Laredo, Jean-Denis Hamze, Bassam; Jeribi, Riadh

    2009-09-15

    Biopsy is usually performed as the first step in percutaneous treatment of osteoid osteomas prior to laser photocoagulation. At our institution, 117 patients with a presumed diagnosis of osteoid osteoma had a trephine biopsy before a percutaneous laser photocoagulation. Biopsies were made using two different types of needles. A Bonopty biopsy needle (14-gauge cannula, 16-gauge trephine needle; Radi Medical Systems, Uppsala, Sweden) was used in 65 patients, and a Laurane biopsy needle (11-gauge cannula, 12.5-gauge trephine needle; Laurane Medical, Saint-Arnoult, France) in 43 patients. Overall biopsy results were positive for osteoid osteoma in 83 (70.9%) of the 117 cases. The Laurane needle provided a significantly higher positive rate (81.4%) than the Bonopty needle (66.1%; p < 0.05). This difference was not due to the size of the nidus, which was similar in the two groups (p < 0.05) and may be an effect of differences in needle caliber (12.5 vs. 14 gauge) as well as differences in needle design. The rate of positive biopsy results obtained in the present series with the Laurane biopsy needle is, to our knowledge, the highest rate reported in series dealing with percutaneous radiofrequency ablation and laser photocoagulation of osteoid osteomas.

  11. A portable, low coherence interferometry based instrument for fine needle aspiration biopsy guidance

    NASA Astrophysics Data System (ADS)

    Iftimia, Nicusor V.; Bouma, Brett E.; Pitman, Martha B.; Goldberg, Brian; Bressner, Jason; Tearney, Guillermo J.

    2005-06-01

    A portable, low coherence interferometry (LCI) based instrument for fine-needle aspiration biopsy guidance is presented. The instrument consists of a fiber-based low coherence interferometer, a data acquisition, processing and display unit, and a probe. The probe, consisting of a 250μm diameter single-mode optical fiber inserted within the bore of a fine needle, is used to illuminate tissue and collect light from tissue at the tip of the needle. Light returning out of the probe is detected by the LCI system, which is capable of measuring depth-resolved information (reflectivity, spectra, birefringence) with a spatial resolution of 10μm over a depth range of approximately 1.4mm. The LCI based instrument can be used to guide the fine needle during biopsy procedures to potentially diagnose neoplasms, infections, inflammations, or infiltrations. The design and performance of the instrument, as well as preliminary measurements on excised breast tissue specimens, are presented in detail.

  12. Demonstration of the self-magnetic-pinch diode as an X-ray source for flash core-punch radiography.

    SciTech Connect

    Cordova, Steve Ray; Rovang, Dean Curtis; Portillo, Salvador; Oliver, Bryan Velten; Bruner, Nichelle Lee; Ziska, Derek Raymond

    2007-10-01

    Minimization of the radiographic spot size and maximization of the radiation dose is a continuing long-range goal for development of electron beam driven X-ray radiography sources. In collaboration with members of the Atomic Weapons Establishment(AWE), Aldermaston UK, the Advanced Radiographic Technologies Dept. 1645 is conducting research on the development of X-ray sources for flash core-punch radiography. The Hydrodynamics Dept. at AWE has defined a near term radiographic source requirement for scaled core-punch experiments to be 250 rads{at}m with a 2.75 mm source spot-size. As part of this collaborative effort, Dept. 1645 is investigating the potential of the Self-Magnetic-Pinched (SMP) diode as a source for core-punch radiography. Recent experiments conducted on the RITS-6 accelerator [1,2] demonstrated the potential of the SMP diode by meeting and exceeding the near term radiographic requirements established by AWE. During the demonstration experiments, RITS-6 was configured with a low-impedance (40 {Omega}) Magnetically Insulated Transmission Line (MITL), which provided a 75-ns, 180-kA, 7.5-MeV forward going electrical pulse to the diode. The use of a low-impedance MITL enabled greater power coupling to the SMP diode and thus allowed for increased radiation output. In addition to reconfiguring the driver (accelerator), geometric changes to the diode were also performed which allowed for an increase in dose production without sacrificing the time integrated spot characteristics. The combination of changes to both the pulsed power driver and the diode significantly increased the source x-ray intensity.

  13. Renal Biopsy in Type 2 Diabetic Patients

    PubMed Central

    Espinel, Eugenia; Agraz, Irene; Ibernon, Meritxell; Ramos, Natalia; Fort, Joan; Serón, Daniel

    2015-01-01

    The majority of diabetic patients with renal involvement are not biopsied. Studies evaluating histological findings in renal biopsies performed in diabetic patients have shown that approximately one third of the cases will show pure diabetic nephropathy, one third a non-diabetic condition and another third will show diabetic nephropathy with a superimposed disease. Early diagnosis of treatable non-diabetic diseases in diabetic patients is important to ameliorate renal prognosis. The publication of the International Consensus Document for the classification of type 1 and type 2 diabetes has provided common criteria for the classification of diabetic nephropathy and its utility to stratify risk for renal failure has already been demonstrated in different retrospective studies. The availability of new drugs with the potential to modify the natural history of diabetic nephropathy has raised the question whether renal biopsies may allow a better design of clinical trials aimed to delay the progression of chronic kidney disease in diabetic patients. PMID:26239461

  14. Muscle biopsy findings in inflammatory myopathies.

    PubMed

    Dalakas, Marinos C

    2002-11-01

    The inflammatory myopathies encompass a heterogeneous group of acquired muscle diseases characterized clinically, by muscle weakness, and histologically, by inflammatory infiltrates within the skeletal muscles. The group of these myopathies comprise three major and discrete subsets: polymyositis (PM), dermatomyositis (DM), and inclusion body myositis (IBM). Each subset retains its characteristic clinical, immunopathologic, and morphologic features regardless of whether it occurs separately or in connection with other systemic diseases. Although the diagnosis of these disorders is based on the combination of clinical examination, electromyographic data, serum muscle enzyme levels, various autoantibodies, and the muscle biopsy findings, the muscle biopsy offers the most definitive diagnostic information in the majority of the cases. This article summarizes the main histologic features that characterize PM, DM, or IBM and emphasizes the main pitfalls associated with interpretation of the biopsies.

  15. Chest Wall Dissemination of Nocardiosis after Percutaneous Transthoracic Needle Biopsy

    SciTech Connect

    Shimamoto, Hiroshi Inaba, Yoshitaka; Yamaura, Hidekazu; Sato, Yozo; Kamiya, Mika; Miyazaki, Masaya; Arai, Yasuaki; Horio, Yoshitsugu

    2007-07-15

    We described a case of chest wall dissemination after percutaneous transthoracic needle biopsy. A 65-year-old man had a lung nodule which was suspected to be lung carcinoma. He underwent percutaneous transthoracic needle biopsy using an 18G semiautomated biopsy needle and pathologic diagnosis showed organizing pneumonia. Two months after the biopsy, chest wall dissemination occurred. Implantation of carcinoma along the biopsy route was suspected, but the mass was actually due to pulmonary nocardiosis.

  16. Characteristics of Bending Parts of Metal Plates Using Ultrasonic Bending Systems with a Vibration Punch and a Vibration Die

    NASA Astrophysics Data System (ADS)

    Tsujino, Jiromaru; Ueoka, Tetsugi; Takiguchi, Kazuhiro; Satoh, Hajime; Takahashi, Kazumitsu

    1993-05-01

    Characteristics of ultrasonic vibration bending of pure aluminum and anticorrosive aluminum plates of 2.0 to 3.0 mm thickness are studied using a 19 kHz longitudinal vibration punch and a 27 kHz vibration die. With ultrasonic vibration, the springback angle decreases to zero under sufficient vibration amplitude, bending angle increases and marked improvement of bending surface condition is obtained. Hardness of the specimen and elongation of the bending surface decrease, and roughness of the bending surface is decreased by vibration. Radius of curvature of the bending part increased to about double that without vibration.

  17. Criteria for initiation of delamination in quasi-static punch-shear tests of a carbon-fiber composite material.

    SciTech Connect

    Chin, Eric Brian; English, Shawn Allen; Briggs, Timothy

    2015-09-01

    V arious phenomenological delamination initiation criteria are analyzed in quasi - static punch - shear tests conducted on six different geometries. These six geometries are modeled and analyzed using elastic, large - deformation finite element analysis. Analysis output is post - processed to assess different delamination initiation criteria, and their applicability to each of the geometries. These criteria are compared to test results to assess whether or not they are appropriate based on what occurred in testing. Further, examinations of CT scans and ultrasonic images o f test specimens are conducted in the appendix to determine the sequence of failure in each test geometry.

  18. Retroperitoneoscopic renal biopsy: still a good indication!

    PubMed

    Micali, Salvatore; Dandrea, Matteo; De Carne, Cosimo; Martorana, Eugenio; De Stefani, Stefano; Cappelli, Gianni; Bianchi, Giampaolo

    2014-01-01

    The histological evaluation of the renal parenchyma is often essential in cases of several renal diseases and provides useful information in determining the prognosis and guiding treatment. In patients with contraindications to percutaneous kidney biopsy, retroperitoneal laparoendoscopic single-site surgery (LESS) is to be preferred as a minimally invasive technique. However, there are cases in which the LESS technique is difficult to perform, especially given that the learning curve is not optimal. We present a case of a Jehovah's Witness patient with severe obesity, in whom conventional retroperitoneal laparoscopic renal biopsy was preferred to the LESS technique. PMID:25198939

  19. Aspiration biopsy cytology of the salivary gland.

    PubMed

    Kline, T S; Merriam, J M; Shapshay, S M

    1981-09-01

    Aspiration biopsy by fine needle from the major salivary glands has been an under-utilized technic in the United States. To evaluate this form of biopsy, 69 patients with salivary gland enlargement were examined by this technic; 47 had confirmative histology. Characteristic ABC patterns were seen in the benign mixed tumor, the papillary cystadenoma lymphomatosum, the mucoepidermoid carcinoma, and malignancy metastatic to the salivary gland. These findings are described. The method proved complication-free and accurate and is recommended for all tumors of the salivary gland.

  20. Case Report: Ischaemic appendicitis post mesenteric biopsy

    PubMed Central

    Zukiwskyj, Marianna; Tun, June; Desai, Shashank

    2016-01-01

    A common indication for laparoscopic mesenteric lymph node biopsy is to provide a tissue diagnosis in the absence of palpable peripheral nodes via a minimally invasive approach.  There are no reports to date of ischaemia to the appendix as a complication of this procedure.   We report the case of a 34-year-old lady who underwent a mesenteric biopsy for a lesion found incidentally on CT to investigate longstanding abdominal pain, and 2 days later required an appendicectomy for ischaemic appendicitis. PMID:26937277

  1. Effects of thermal fatigue on shear punch strength of tooth-colored restoratives

    PubMed Central

    Melody, Fam Mei Shi; U-Jin, Yap Adrian; Natalie, Tan Wei Min; Elizabeth, Tay Wan Ling; Chien, Jessica Yeo Siu

    2016-01-01

    Aims: This study investigated the effect of thermal fatigue on the shear strength of a range of tooth-colored restorative materials including giomers, zirconia-reinforced glass ionomer cement (GIC), nano-particle resin-modified GIC, highly viscous GICs, and composite resin. Materials and Methods: Twenty specimens of each material were fabricated in standardized washers (17 mm outer diameter, 9 mm internal diameter, 1 mm thick). The specimens were cured, stored in 100% humidity at 37.5°C for 24 h, and randomly divided into two groups of 10. Group A specimens were nonthermocycled (NT) and stored in distilled water at 37°C for 168 h. Group B specimens were thermocycled (TC) for 10,000 cycles (168 h) with baths X, Y, and Z adjusted to 35°C, 15°C, and 45°C, respectively. Each cycle had dwell times of 28 s in X, and 2s in Y/Z in the order XYXZ. Specimens then underwent shear punch testing at a crosshead speed of 0.5 mm/min with a 2 kN load cell. Statistical analysis of shear strength was done using t-test and two-way ANOVA/Scheffe's post hoc test at significance level P < 0.05. Results: The effect of thermal fatigue on shear strength was material dependent. Except for the “sculptable” giomer (Beautifil II) and a highly viscous GIC (Fuji IX GP Fast), no significant differences in shear strength were generally observed between the NT and TC groups. For both groups, the composite resin (Filtek Z250XT) had the highest shear strength while the zirconia-reinforced (zirconomer) and a highly viscous GIC (Ketac Molar Quick) had the lowest. Conclusions: The effect of thermocycling on shear strength was material dependent. Thermal fatigue, however, did not significantly influence the shear strength of most materials assessed. The “sculptable” composite and giomer were significantly stronger than the other materials evaluated. Shear strength of the “flowable” injectable hybrid giomer was intermediate between the composite and GICs. PMID:27563182

  2. Simulated prostate biopsy: prostate cancer distribution and clinical correlation

    NASA Astrophysics Data System (ADS)

    Bauer, John J.; Zeng, Jianchao; Zhang, Wei; Sesterhenn, Isabell A.; Dean, Robert; Moul, Judd W.; Mun, Seong K.

    2000-04-01

    Our group has recently obtained data based upon whole- mounted step-sectioned radical prostatectomy specimens using a 3D computer assisted prostate biopsy simulator that suggests an increased detection rate is possible using laterally placed biopsies. A new 10-core biopsy pattern was demonstrated to be superior to the traditional sextant biopsy. This patter includes the traditional sextant biopsy cores and four laterally placed biopsies in the right and left apex and mid portion of the prostate gland. The objective of this study is to confirm the higher prostate cancer defection rate obtained using our simulated 10-core biopsy pattern in a small clinical trial. We retrospectively reviewed 35 consecutive patients with a pathologic diagnosis of prostate cancer biopsied by a single urologist using the 10-core prostate biopsy patterns were compared with respect to prostate cancer detection rate. Of the 35 patients diagnosed with prostate cancer, 54.3 percent were diagnosed when reviewing the sextant biopsy data only. Review of the 10-core pattern revealed that an additional 45.7 percent were diagnosed when reviewing the sextant biopsy data only. Review of the 10-core pattern revealed that an additional 45.7 percent of patients were diagnosed solely with the laterally placed biopsies. Our results suggest that biopsy protocols that use laterally placed biopsies based upon a five region anatomical model are superior to the routinely used sextant prostate biopsy pattern.

  3. Studies on Punching Shear Resistance of Two Way Slab Specimens with Partial Replacement of Cement by GGBS with Different Edge Conditions

    NASA Astrophysics Data System (ADS)

    Nemani, Ravi Dakshina Murthy; Rao, M. V. S.; Grandhe, Veera Venkata Satya Naranyana

    2016-09-01

    The present work is an effort to quantify the punching shear load resistance effect on two way simply supported slab specimens with replacement of cement by Ground Granulated Blast Furnace Slag (GGBS) with different edge conditions at various replacement levels and evaluate its efficiency. GGBS replacement has emerged as a major alternative to conventional concrete and has rapidly drawn the concrete industry attention due to its cement savings, cost savings, environmental and socio-economic benefits. The two way slab specimens were subjected to punching shear load by in house fabricated apparatus. The slab specimens were cast using M30 grade concrete with HYSD bars. The cement was partially replaced with GGBS at different percentages i.e., 0 to 30 % at regular intervals of 10 %. The test results indicate that the two way slab specimens with partial replacement of cement by GGBS exhibit high resistance against punching shear when compared with conventional concretes slab specimens.

  4. The renal biopsy in the genomic era.

    PubMed

    Liapis, Helen; Gaut, Joseph P

    2013-08-01

    Renal biopsy was introduced in the 1950s. By 1980 the pathologic diagnostic criteria for the majority of medical kidney diseases known today, including pediatric diseases, were established using light, electron microscopy and immunohistochemistry. However, it has become clear that there are limitations in the morphologic evaluation, mainly because a given pattern of injury can be caused by different aetiologies and, conversely, a single aetiology may present with more than one histological pattern. An explosion in kidney disease research in the last 20-30 years has brought new knowledge from bench to bedside rapidly and resulted in new molecular and genetic tools that enhance the diagnostic and prognostic power of the renal biopsy. Genomic technologies such as polymerase chain reaction (PCR), in situ hybridization and oligonucleotide microarrays, collectively known as genomics, detect single or multiple genes underscoring the pathologic changes and revealing specific causes of injury that may require different treatment. The aims of this review are to (1) summarize current recommendations for diagnostic renal biopsies encompassing light microscopy, immunofluorescence or immunohistochemistry and electron microscopy; (2) address the limitations of morphology; (3) show current contributions of genomic technologies adjunct to the renal biopsy, and provide examples of how these may transform pathologic interpretation into molecular disease phenotypes.

  5. Clinical role of the renal transplant biopsy

    PubMed Central

    Williams, Winfred W.; Taheri, Diana; Tolkoff-Rubin, Nina; Colvin, Robert B.

    2013-01-01

    Percutaneous needle core biopsy is the definitive procedure by which essential diagnostic and prognostic information on acute and chronic renal allograft dysfunction is obtained. The diagnostic value of the information so obtained has endured for over three decades and has proven crucially important in shaping strategies for therapeutic intervention. This Review provides a broad outline of the utility of performing kidney graft biopsies after transplantation, highlighting the relevance of biopsy findings in the immediate and early post-transplant period (from days to weeks after implantation), the first post-transplant year, and the late period (beyond the first year). We focus on how biopsy findings change over time, and the wide variety of pathological features that characterize the major clinical diagnoses facing the clinician. This article also includes a discussion of acute cellular and humoral rejection, the toxic effects of calcineurin inhibitors, and the widely varying etiologies and characteristics of chronic lesions. Emerging technologies based on gene expression analyses and proteomics, the in situ detection of functionally relevant molecules, and new bioinformatic approaches that hold the promise of improving diagnostic precision and developing new, refined molecular pathways for therapeutic intervention are also presented. PMID:22231130

  6. Frictional insertion kinetics of bone biopsy needles.

    PubMed

    Heiner, A D; Brown, T D; Rossin, V; Buckwalter, J A

    2001-12-01

    Patients undergoing a percutaneous bone biopsy often complain of pain during needle insertion, despite local anesthesia. Bone biopsy needles are typically inserted with combined axial and twisting motions. These motions could cause pain through frictional heating or direct mechanical irritation. The hypothesis of this study is that the insertion energy of bone biopsy needles can be reduced by modifying the insertion kinetics or by adding a friction-lowering coating to the needles. Jamshidi bone biopsy needles were driven into a bone analog model by an MTS materials testing machine operating under axial and rotational displacement control. The load/torque recordings showed that, to significantly decrease insertion energy and peak resistance to needle insertion, axial velocity and angular frequency had to be decreased to one quarter of the baseline, typical-usage parameters. However the increased insertion time may not be acceptable clinically. The majority of the insertion energy was associated with the needle axial thrust rather than with needle twisting. Overcoming friction against the side of the needle consumed much more of the insertion energy than did the process of cutting per se. None of five needle coatings tested succeeded in appreciably lowering the insertion energy, and none achieved a substantial decrease in peak resisting force.

  7. Evaluation of the Punch-it™ NA-Sample kit for detecting microbial DNA in blood culture bottles using PCR-reverse blot hybridization assay.

    PubMed

    Kim, Jungho; Wang, Hye-Young; Kim, Seoyong; Park, Soon Deok; Yu, Kwangmin; Kim, Hyo Youl; Uh, Young; Lee, Hyeyoung

    2016-09-01

    DNA extraction efficiency affects the success of PCR-based method applications. The Punch-it™ NA-Sample kit for extracting DNA by using paper chromatography is technically easy to use and requires just two reagents and only 10min to complete. The Punch-it™ NA-Sample kit could be offered as a rapid, accurate, and convenient method for extracting bacterial and fungal DNA from blood culture bottles. We compared the efficiencies of the commercial kit (Punch-it™ NA-Sample kit) and an in-house conventional boiling method with Chelex-100 resin for DNA extraction from blood culture bottles. The efficiency of the two DNA extraction methods was assessed by PCR-reverse blot hybridization assay (PCR-REBA, REBA Sepsis-ID) for detecting Gram positive (GP) bacteria, Gram negative (GN) bacteria, and Candida species with 196 positive and 200 negative blood culture bottles. The detection limits of the two DNA extraction methods were 10(3)CFU/mL for GP bacteria, 10(3)CFU/mL for GN bacteria, and 10(4)CFU/mL for Candida. The sensitivity and specificity of the Punch-it™ NA-Sample kit by REBA Sepsis-ID were 95.4% (187/196) and 100% (200/200), respectively. The overall agreement of the two DNA extraction methods was 98.9% (392/396). Three of four samples showing discrepant results between the two extraction methods were more accurately matched up with the Punch-it™ NA-Sample kit based on conventional culture methods. The results indicated that the Punch-it™ NA-Sample kit extracted bacterial and fungal DNA in blood culture bottles and allowed extracted DNA to be used in molecular assay. PMID:27263831

  8. Molecular image-directed biopsies: improving clinical biopsy selection in patients with multiple tumors

    NASA Astrophysics Data System (ADS)

    Harmon, Stephanie A.; Tuite, Michael J.; Jeraj, Robert

    2016-10-01

    Site selection for image-guided biopsies in patients with multiple lesions is typically based on clinical feasibility and physician preference. This study outlines the development of a selection algorithm that, in addition to clinical requirements, incorporates quantitative imaging data for automatic identification of candidate lesions for biopsy. The algorithm is designed to rank potential targets by maximizing a lesion-specific score, incorporating various criteria separated into two categories: (1) physician-feasibility category including physician-preferred lesion location and absolute volume scores, and (2) imaging-based category including various modality and application-specific metrics. This platform was benchmarked in two clinical scenarios, a pre-treatment setting and response-based setting using imaging from metastatic prostate cancer patients with high disease burden (multiple lesions) undergoing conventional treatment and receiving whole-body [18F]NaF PET/CT scans pre- and mid-treatment. Targeting of metastatic lesions was robust to different weighting ratios and candidacy for biopsy was physician confirmed. Lesion ranked as top targets for biopsy remained so for all patients in pre-treatment and post-treatment biopsy selection after sensitivity testing was completed for physician-biased or imaging-biased scenarios. After identifying candidates, biopsy feasibility was evaluated by a physician and confirmed for 90% (32/36) of high-ranking lesions, of which all top choices were confirmed. The remaining cases represented lesions with high anatomical difficulty for targeting, such as proximity to sciatic nerve. This newly developed selection method was successfully used to quantitatively identify candidate lesions for biopsies in patients with multiple lesions. In a prospective study, we were able to successfully plan, develop, and implement this technique for the selection of a pre-treatment biopsy location.

  9. Performance and Cost of Disposable Biopsy Forceps in Upper Gastrointestinal Endoscopy: Comparison with Reusable Biopsy Forceps

    PubMed Central

    Lim, Chul-Hyun; Kim, Won Chul; Kim, Jin Soo; Cho, Yu Kyung; Park, Jae Myung; Lee, In Seok; Kim, Sang Woo; Choi, Kyu Yong; Chung, In-Sik

    2012-01-01

    Background/Aims It is believed that disposable biopsy forceps are more costly than reusable biopsy forceps. In this study, we evaluated performance and cost of disposable forceps versus reusable forceps in esophagogastroduodenoscopic biopsy. Methods Between October 2009 and July 2010, we enrolled 200 patients undergoing esophagogastroduodenoscopic biopsy at Seoul St. Mary's Hospital. Biopsies were performed with 100 disposable or 5 reusable forceps by random assignment. Seventy-five additional patients were studied to estimate durability of reusable forceps. The assisting nurses estimated the performance of the forceps. The evaluation of costs included purchase prices and reprocessing costs. The adequacy of the sample was estimated according to the diameter of the obtained tissue. Results Performance of disposable forceps was estimated as excellent in 97.0%, good in 2.0% and adequate in 1.0%. Reusable forceps were estimated as excellent in 36.0%, good in 36.0%, adequate in 25.1% and inadequate in 2.9%. The performance of reusable forceps declined with the number of uses. The reprocessing cost of reusable forceps for one biopsy session was calculated as ₩8,021. The adequacy of the sample was excellent for both forceps. Conclusions Disposable forceps showed excellent performance. Considering the reprocessing costs of reusable forceps, usage of disposable forceps with a low price should be considered. PMID:22741133

  10. Multiple Biopsies and Detection of Cervical Cancer Precursors at Colposcopy

    PubMed Central

    Wentzensen, Nicolas; Walker, Joan L.; Gold, Michael A.; Smith, Katie M.; Zuna, Rosemary E.; Mathews, Cara; Dunn, S. Terence; Zhang, Roy; Moxley, Katherine; Bishop, Erin; Tenney, Meaghan; Nugent, Elizabeth; Graubard, Barry I.; Wacholder, Sholom; Schiffman, Mark

    2015-01-01

    Purpose Women with abnormal cervical cancer screening results are referred to colposcopy and biopsy for diagnosis of cervical cancer precursors (high-grade squamous intraepithelial lesions [HSILs]). Colposcopy with a single biopsy can miss identification of HSILs. No systematic study has quantified the improved detection of HSIL by taking multiple lesion-directed biopsies. Methods The Biopsy Study was an observational study of 690 women referred to colposcopy after abnormal cervical cancer screening results. Up to four directed biopsies were taken from distinct acetowhite lesions and ranked by colposcopic impression. A nondirected biopsy of a normal-appearing area was added if fewer than four directed biopsies were taken. HSIL identified by any biopsy was the reference standard of disease used to evaluate the incremental yield and sensitivity of multiple biopsies. Results In the overall population, sensitivities for detecting HSIL increased from 60.6% (95% CI, 54.8% to 66.6%) from a single biopsy to 85.6% (95% CI, 80.3% to 90.2%) after two biopsies and to 95.6% (95% CI, 91.3% to 99.2%) after three biopsies. A significant increase in sensitivity of multiple biopsies was observed in all subgroups. The highest increase in yield of HSIL was observed for women with a high-grade colposcopic impression, HSIL cytology, and human papillomavirus (HPV) type 16 positivity. Only 2% of all HSILs diagnosed in the participants were detected by biopsies of normal-appearing transformation zone. Conclusion Collection of additional lesion-directed biopsies during colposcopy increased detection of histologic HSIL, regardless of patient characteristics. Taking additional biopsies when multiple lesions are present should become the standard practice of colposcopic biopsy. PMID:25422481

  11. Achromatized endomicroscope objective for optical biopsy

    PubMed Central

    Kyrish, Matthew; Tkaczyk, Tomasz S.

    2013-01-01

    Currently, researchers and clinicians lack achromatized endomicroscope objectives that are as narrow as biopsy needles. We present a proof-of-concept prototype that validates the optical design of an NA0.4 objective. The objective, built with plastic lenses, has a 0.9 mm clear aperture and is achromatized from 452 nm to 623 nm. The objective’s measured Strehl ratio is 0.74 ± 0.05 across a 250 μm FOV. We perform optical sectioning via structured illumination through the objective while capturing fluorescence images of breast carcinoma cells stained with proflavine and cresyl violet. This technology has the potential to improve optical biopsies and provide the next step forward in cancer diagnostics. PMID:23412009

  12. Cerebral Whipple's disease. Diagnosis by brain biopsy.

    PubMed

    Johnson, L; Diamond, I

    1980-10-01

    Whipple's disease, a multisystem chronic granulomatous disease treatable by antibiotics, usually presents clinically with gastrointestinal or joint symptoms. Usually, the diagnosis is substantiated by small intestinal biopsy. This shows diastase-resistant periodic-acid-Schiff-(PAS)-positive inclusions in the cytoplasm of macrophages within the lamina propria. By electron microscopy, this PAS-positive material consists of 1.5 X 0.2-mum bacilli and fine fibrillar material within macrophage phagolysosomes. Rarely, Whipple's disease presents clinically as a primary neurologic disease without gastrointestinal symptoms. Because untreated cerebral Whipple's disease usually progresses rapidly to death, it is imperative to establish the diagnosis promptly. This report describes a case of cerebral Whipple's disease without gastrointestinal symptoms that was diagnosed early by light-and electron-microscopic study of brain biopsy material. PMID:6158859

  13. Computer assisted biopsy of breast tumors.

    PubMed

    Arambula Cosio, Fernando; Lira Berra, Eric; Hevia Montiel, Nidiyare; Garcia Segundo, Cresencio; Garduno, Edgar; Alvarado Gonzalez, Montserrat; Quispe Siccha, Rosa Ma; Reyes Ramirez, Bartolome; Hazan Lasri, Eric

    2010-01-01

    In this paper we report our preliminary results of the development of a computer assisted system for breast biopsy. The system is based on tracked ultrasound images of the breast. A three dimensional ultrasound volume is constructed from a set of tracked B-scan images acquired with a calibrated probe. The system has been designed to assist a radiologist during breast biopsy, and also as a training system for radiology residents. A semiautomatic classification algorithm was implemented to assist the user with the annotation of the tumor on an ultrasound volume. We report the development of the system prototype, tested on a physical phantom of a breast with a tumor, made of polivinil alcohol. PMID:21097108

  14. Accessing Genetic Information with Liquid Biopsies.

    PubMed

    Cai, Xuyu; Janku, Filip; Zhan, Qimin; Fan, Jian-Bing

    2015-10-01

    Recent scientific advances in understanding circulating tumor cells, cell-free DNA/RNA, and exosomes in blood have laid a solid foundation for the development of routine molecular 'liquid biopsies'. This approach provides non-invasive access to genetic information--somatic mutations, epigenetic changes, and differential expression--about the physiological conditions of our body and diseases. It opens a valuable avenue for future genetic studies and human disease diagnosis, including prenatal and neurodegenerative disease diagnosis, as well as for cancer screening and monitoring. With the rapid development of highly sensitive and accurate technologies such as next-generation sequencing, molecular 'liquid biopsies' will quickly become a central piece in the future of precision medicine.

  15. Factors that can minimize bleeding complications after renal biopsy.

    PubMed

    Zhu, M S; Chen, J Z; Xu, A P

    2014-10-01

    Renal biopsy is a very important diagnostic tool in the evaluation of renal diseases. However, bleeding remains to be one of the most serious complications in this procedure. Many new techniques have been improved to make it safer. The risk factors and predictors of bleeding after percutaneous renal biopsy have been extensively reported in many literatures, and generally speaking, the common risk factors for renal biopsy complications focus on hypertension, high serum creatinine, bleeding diatheses, amyloidosis, advanced age, gender and so on. Our primary purpose of this review is to summarize current measures in recent years literature aiming at minimizing the bleeding complication after the renal biopsy, including the drug application before and after renal biopsy, operation details in percutaneous renal biopsies, nursing and close monitoring after the biopsy and other kinds of biopsy methods.

  16. A Prospective Randomized Trial of Two Different Prostate Biopsy Schemes

    ClinicalTrials.gov

    2016-07-03

    Prostate Cancer; Local Anesthesia; Prostate-Specific Antigen/Blood; Biopsy/Methods; Image-guided Biopsy/Methods; Prostatic Neoplasms/Diagnosis; Prostate/Pathology; Prospective Studies; Humans; Male; Ultrasonography, Interventional/Methods

  17. Preliminary study of tendon biopsy in the horse.

    PubMed

    Webbon, P M

    1986-09-01

    A series of experimental tendon biopsies is described. Three biopsies were taken from the lateral digital extensor tendon (LDET) and three from the superficial flexor tendon (SFT). The LDET biopsies resulted in little discomfort whereas the SFT biopsies led to temporary lameness. The tendons were examined histologically up to 99 days after the biopsies were removed. In all of the tendons the defect filled with granulation tissue which subsequently became organised as a longitudinally orientated collagenous scar tissue. In this small series of biopsies the histological effects of the biopsy persisted longer in the SFT than in the LDET. It is concluded that tendon biopsy cannot be advocated for safe routine use in the horse.

  18. Salivary Gland Biopsy Shows Promise to Helping to Diagnose Parkinson's

    MedlinePlus

    ... Parkinson's HelpLine Learn More Science News Salivary Gland Biopsy Shows Promise to Helping to Diagnose Parkinson’s - Mar ... team performed a procedure called a needle core biopsy of the submandibular glands in 15 people who ...

  19. Conjunctival biopsy in adult form galactosialidosis.

    PubMed Central

    Usui, T; Sawaguchi, S; Abe, H; Iwata, K; Oyanagi, K

    1993-01-01

    Conjunctival biopsy was performed in two siblings with adult-form galactosialidosis. Electron microscopically, several types of intracytoplasmic inclusion were observed in the fibroblasts in conjunctival stroma, lymphatic capillary endothelial cells, Schwann cells, and epithelial cells. Membrane-bound vesicles with fibrillogranular content were frequently observed, and occasional lamellar structures were noted in these inclusions. Dense granular inclusions and oil droplets were also seen. Dense granular inclusions have not been reported in this disease previously. Images PMID:8384473

  20. [Is undirected liver biopsy a safe procedure?].

    PubMed

    Oliva, L; Hirt, M

    1993-09-01

    In the authors' group of 976 umaimed liver biopsies (ULB) 10 complications were recorded. The authors described them and compared them with reports from the world literature. Two patients from the group died after ULB. One as a result of biopsy from haemoperitoneum, the other patient died with delirium tremens after surgery called for by persisting peritoneal syndrome. In eight patients mild complications were involved. In five patients complications receded spontaneously, in three after administration of an analgetic. From the submitted paper ensues that ULB is not quite safe, even when used by an experienced physician and when all contraindications are respected. A smooth course is not ensured by a risk-free diagnosis, previous uncomplicated biopsies normal prebioptic haemocoagulation tests. It is essential to realize this with regard to every patient where we indicate ULB. It is better to omit it unless we are unequivocally convinced of its asset. The question thus is: What will be the benefit of ULB for the patient?

  1. 21 CFR 878.4755 - Absorbable lung biopsy plug.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Absorbable lung biopsy plug. 878.4755 Section 878...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4755 Absorbable lung biopsy plug. (a) Identification. A preformed (polymerized) absorbable lung biopsy plug is intended to...

  2. A new apparatus for standardized rat kidney biopsy.

    PubMed

    Schirutschke, Holger; Gladrow, Lars; Norkus, Christian; Parmentier, Simon Paul; Hohenstein, Bernd; Hugo, Christian P M

    2014-01-01

    Survival biopsies are frequently applied in rat kidney disease models, but several drawbacks such as surgical kidney trauma, bleeding risk and variable loss of kidney tissue are still unsolved. Therefore, we developed an easy-to-use core biopsy instrument and evaluated whether two consecutive kidney biopsies within the same kidney can be carried out in a standardized manner. On day 0, 18 Lewis rats underwent a right nephrectomy and 9 of these rats a subsequent first biopsy of the left kidney (Bx group). 9 control rats had a sham biopsy of the left kidney (Ctrl group). On day 7, a second kidney biopsy/sham biopsy was performed. On day 42, all animals were sacrificed and their kidneys were removed for histology. Biopsy cylinders contained 57±28 glomeruli per transversal section, representing an adequate sample size. PAS staining showed that the biopsy depth was limited to the renal cortex whereas surgical tissue damage was limited to the area immediately adjacent to the taken biopsy cylinder. On day 42, the reduction of functional renal mass after two biopsies was only 5.2% and no differences of body weight, blood pressure, proteinuria, serum creatinine, glomerulosclerosis, interstitial fibrosis or number of ED-1 positive macrophages were found between both groups. In summary, our apparatus offers a safe method to perform repetitive kidney biopsies with minimal trauma and sufficient sample size and quality even in experimental disease models restricted to one single kidney.

  3. 21 CFR 876.1075 - Gastroenterology-urology biopsy instrument.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Gastroenterology-urology biopsy instrument. 876... SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Diagnostic Devices § 876.1075 Gastroenterology-urology biopsy instrument. (a) Identification. A gastroenterology-urology biopsy instrument is...

  4. 21 CFR 876.1075 - Gastroenterology-urology biopsy instrument.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Gastroenterology-urology biopsy instrument. 876... SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Diagnostic Devices § 876.1075 Gastroenterology-urology biopsy instrument. (a) Identification. A gastroenterology-urology biopsy instrument is...

  5. 21 CFR 876.1075 - Gastroenterology-urology biopsy instrument.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Gastroenterology-urology biopsy instrument. 876... SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Diagnostic Devices § 876.1075 Gastroenterology-urology biopsy instrument. (a) Identification. A gastroenterology-urology biopsy instrument is...

  6. 21 CFR 876.1075 - Gastroenterology-urology biopsy instrument.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Gastroenterology-urology biopsy instrument. 876... SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Diagnostic Devices § 876.1075 Gastroenterology-urology biopsy instrument. (a) Identification. A gastroenterology-urology biopsy instrument is...

  7. A New Apparatus for Standardized Rat Kidney Biopsy

    PubMed Central

    Schirutschke, Holger; Gladrow, Lars; Norkus, Christian; Parmentier, Simon Paul; Hohenstein, Bernd; Hugo, Christian P. M.

    2014-01-01

    Survival biopsies are frequently applied in rat kidney disease models, but several drawbacks such as surgical kidney trauma, bleeding risk and variable loss of kidney tissue are still unsolved. Therefore, we developed an easy-to-use core biopsy instrument and evaluated whether two consecutive kidney biopsies within the same kidney can be carried out in a standardized manner. On day 0, 18 Lewis rats underwent a right nephrectomy and 9 of these rats a subsequent first biopsy of the left kidney (Bx group). 9 control rats had a sham biopsy of the left kidney (Ctrl group). On day 7, a second kidney biopsy/sham biopsy was performed. On day 42, all animals were sacrificed and their kidneys were removed for histology. Biopsy cylinders contained 57±28 glomeruli per transversal section, representing an adequate sample size. PAS staining showed that the biopsy depth was limited to the renal cortex whereas surgical tissue damage was limited to the area immediately adjacent to the taken biopsy cylinder. On day 42, the reduction of functional renal mass after two biopsies was only 5.2% and no differences of body weight, blood pressure, proteinuria, serum creatinine, glomerulosclerosis, interstitial fibrosis or number of ED-1 positive macrophages were found between both groups. In summary, our apparatus offers a safe method to perform repetitive kidney biopsies with minimal trauma and sufficient sample size and quality even in experimental disease models restricted to one single kidney. PMID:25506931

  8. 21 CFR 876.1075 - Gastroenterology-urology biopsy instrument.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Gastroenterology-urology biopsy instrument. 876... SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Diagnostic Devices § 876.1075 Gastroenterology-urology biopsy instrument. (a) Identification. A gastroenterology-urology biopsy instrument is...

  9. Effects of two systemic fungicides: Artea (Propiconazole+cyproconazole) and Punch (Flusilazole) on the physiology and the respiratory metabolism of durum wheat (Triticum durum L.).

    PubMed

    Bensoltane, S; Youbi, M; Djebar, H; Djebar, M R

    2006-01-01

    The present work aimed at the study of the effects of Artea and Punch; two systemic fungicides on durum Wheat (Triticum durum L. cv. GTA dur). Seeds were grown in a medium containing respectively 25, 50, 75 and 100 ppm of Artea and Punch under controlled conditions. After measuring root number and length, eight-day-old-root tips were used to determine Catalase (EC 1.11.1.6), Ascorbate-Peroxidase (EC 1.11.1.11) and Guaïacol-Peroxidase (EC 1.11.1.7) enzymatic activities. Root respiratory activity was also determined using a polarographic method (Clark electrode). Fungicide treatment triggered a decrease in root number and length for both fungicides. On the other hand, treatment with Artea and Punch resulted in an enhancement of the respiratory activity and increased antioxidative enzymatic levels in durum wheat roots. Activities of Catalase, Ascorbate-Peroxydase and Guaïacol-Peroxydase increased proportionally and were more meaningful at high concentrations (75 and 100 ppm) compared with controls. Modulations in respiratory metabolism and antioxidant system could probably be the result of Artea/Punch-induced toxicity which could lead to an oxidative stress status. The present study enhances previous works relevant to the toxic effects induced by systemic fungicides on plants.

  10. Small Punch Creep Studies for Optimization of Nitrogen Content in 316LN SS for Enhanced Creep Resistance

    NASA Astrophysics Data System (ADS)

    Mathew, M. D.; Ganesh Kumar, J.; Ganesan, V.; Laha, K.

    2014-02-01

    Small punch creep (SPC) studies have been carried out to evaluate the creep properties of 316LN stainless steel (SS) at 923 K (650 °C) at various stress levels. The results have been compared with uniaxial creep rupture data obtained from conventional creep tests. The minimum deflection rate was found to obey Norton power law. SPC rupture life was correlated with uniaxial creep rupture life. The influence of nitrogen content on the creep rupture properties of 316LN SS was investigated in the range of 0.07 to 0.14 wt pct. SPC rupture life increased and the minimum deflection rate decreased with the increase in nitrogen content. The trends were found to be in agreement with the results obtained from uniaxial creep rupture tests. These studies have established that SPC is a fast and reliable technique to screen creep properties of different experimental heats of materials for optimizing the chemical composition for developing creep-resistant materials.

  11. Estimation of mechanical properties of irradiated nuclear pressure vessel steel by use of subsized CT specimen and small punch specimen

    SciTech Connect

    Mao, X. . Dept. of Mechanical Engineering); Takahashi, H. ); Kodaira, T. )

    1991-11-01

    This paper reports on the 2-1/4 Cr-1M{sub 0} steel that has been selected as the material for the reactor pressure vessel (RPV) of a multipurpose experimental high temperature gas cooled reactor designed by JAERI. The 2-1/4 Cr-1M{sub 0} steel has successful records for high temperature pressure vessels in the petrochemical industries and the ASME Code Case authorizes the use of the steel in these pressure vessels. However, the steel has not been used to nuclear reactor pressure vessels so far. Since the material in the so-called belt line region of the nuclear pressure vessels undergo changes in toughness and strength due to neutron irradiation, it is quite urgent to collect the fracture toughness and strength data of the irradiated steel for the evaluation of the structural intergravity of the reactor pressure vessel of high radiation resistance. In order to study irradiation damage of 2-1/4 Cr-1M{sub 0} steel, small specimens are required because of the severe limitations on specimen size in irradiated-material testing facilities (e.g. the limited space available for testing in nuclear reactors and the narrow damage zone produced by charged particle accelerators). In order to obtain more information about fracture properties of the 2-1/4 Cr- 1M{sub 0} steel from specimens, a subsized compact tensile (CT) specimen, a small punch (SP) specimen and tensile specimen of the irradiated 2-1/4 Cr-1M{sub 0} steel were used to provide radiation effects on fracture toughness, yield strength and ultimate strength. The small punch test, which has been developed recently provides information of the yield and ultimate strength as well as fracture toughness. This report describes the behavior of the neutron irradiation embrittlement of the nuclear reactor pressure vessel steel 2-1/4 Cr-1M{sub 0} by use of new testing approach - subsized specimen techniques.

  12. Fatal haemorrhage following liver biopsy in patients with HIV infection.

    PubMed Central

    Churchill, D R; Mann, D; Coker, R J; Miller, R F; Glazer, G; Goldin, R D; Lucas, S B; Weber, J N; De Cock, K M

    1996-01-01

    A retrospective review of all 248 liver biopsies performed in patients with HIV infection at two referral centres in London over a 12 year period revealed five cases of major bleeding following biopsy, with four deaths. The risk of major bleeding was 2.0%, and mortality was 1.6% following liver biopsy. The risk of bleeding as much higher than in published series of biopsies done in patients without HIV infection, owing in part to the high prevalence of thrombocytopaenia and clotting abnormalities in patients with HIV infection. HIV infection per se may also increase the risk of bleeding following liver biopsy. PMID:8655172

  13. Value of repeat biopsy in lupus nephritis flares

    PubMed Central

    Greloni, G; Scolnik, M; Marin, J; Lancioni, E; Quiroz, C; Zacariaz, J; De la Iglesia Niveyro, P; Christiansen, S; Pierangelo, M A; Varela, C F; Rosa-Diez, G J; Catoggio, L J; Soriano, E R

    2014-01-01

    Objectives Renal flares are common in lupus nephritis (LN), and class switch is thought to be characteristic. There is no agreement on indications for performing a repeat renal biopsy. Our objective was to retrospectively review patients who had more than one renal biopsy performed on clinical indications, and analyse clinical, pathological and treatment changes after successive biopsies. Methods Forty-five patients with LN and one or more repeat renal biopsies were included, with a total of 116 biopsies. Results Of the 71 repeat biopsies, pathological transition occurred in 39 (54.9%). When having a previous biopsy with a proliferative lesion, class switch occurred in 55.6%, with 24.4% evolving into non-proliferative classes. When previous biopsy was class V, transition to other classes occurred in 58.3% and changes were all into proliferative classes. Conversion from one pure proliferative form to another (class III to class IV or vice versa) happened in 11.3% of the rebiopsies, with 62 rebiopsies (87.3%) leading to a change in the treatment regimen. Conclusions Histological transformations were common, and they occurred when the previous biopsy had non-proliferative lesions as well as when lesions were proliferative. Treatments were modified after repeat renal biopsy in the majority of patients. In this experience, kidney repeat biopsies were useful in guiding treatment of LN flares. PMID:25396056

  14. Transthoracic needle biopsy of the lung

    PubMed Central

    DiBardino, David M.; Yarmus, Lonny B.

    2015-01-01

    Background Image guided transthoracic needle aspiration (TTNA) is a valuable tool used for the diagnosis of countless thoracic diseases. Computed tomography (CT) is the most common imaging modality used for guidance followed by ultrasound (US) for lesions abutting the pleural surface. Novel approaches using virtual CT guidance have recently been introduced. The objective of this review is to examine the current literature for TTNA biopsy of the lung focusing on diagnostic accuracy and safety. Methods MEDLINE was searched from inception to October 2015 for all case series examining image guided TTNA. Articles focusing on fluoroscopic guidance as well as influence of rapid on-site evaluation (ROSE) on yield were excluded. The diagnostic accuracy, defined as the number of true positives divided by the number of biopsies done, as well as the complication rate [pneumothorax (PTX), bleeding] was examined for CT guided TTNA, US guided TTNA as well as CT guided electromagnetic navigational-TTNA (E-TTNA). Of the 490 articles recovered 75 were included in our analysis. Results The overall pooled diagnostic accuracy for CT guided TTNA using 48 articles that met the inclusion and exclusion criteria was 92.1% (9,567/10,383). A similar yield was obtained examining ten articles using US guided TTNA of 88.7% (446/503). E-TTNA, being a new modality, only had one pilot study citing a diagnostic accuracy of 83% (19/23). Pooled PTX and hemorrhage rates were 20.5% and 2.8% respectively for CT guided TTNA. The PTX rate was lower in US guided TTNA at a pooled rate of 4.4%. E-TTNA showed a similar rate of PTX at 20% with no incidence of bleeding in a single pilot study available. Conclusions Image guided TTNA is a safe and accurate modality for the biopsy of lung pathology. This study found similar yield and safety profiles with the three imaging modalities examined. PMID:26807279

  15. Critical assessment of diagnostic value of endomyocardial biopsy. Assessment of cardiac biopsy.

    PubMed Central

    MacKay, E H; Littler, W A; Sleight, P

    1978-01-01

    Right or left ventricular endomyocardial biopsy with the Konno or the Olympus bioptome was attempted in 73 patients aged 5 months to 61 years, with 82 per cent success. Light and electron microscopy showed non-specific features in over half the biopsies with new or diagnostically useful information in only 10 per cent of cases, usually as a result of electron microscopy. The method is safe but is of strictly limited diagnostic value and is likely to be of most help as a research tool in the biochemical study of cardiomyopathies. Images PMID:626666

  16. Endobronchial biopsies on aspirin and prasugrel.

    PubMed

    Harris, Kassem; Kebbe, Jad

    2015-06-01

    Patients are generally required to stop antiplatelet therapy prior to elective invasive procedures. Some patients receive dual antiplatelet therapy for recent vascular procedures such as drug-eluting coronary stenting, and early discontinuation of antiplatelet agents could lead to a significant risk of stent thrombosis. Most bronchoscopic procedures are performed on patients using Aspirin but not on those using Clopidogrel or Prasugrel. In this report, we describe a unique case of a patient with a recent placement of drug-eluting stents, who required endobronchial biopsies for evaluation of lung cancer recurrence. The procedure was performed successfully and safely with no complications. PMID:25697386

  17. Core needle biopsies and surgical excision biopsies in the diagnosis of lymphoma-experience at the Lymph Node Registry Kiel.

    PubMed

    Johl, Alice; Lengfelder, Eva; Hiddemann, Wolfgang; Klapper, Wolfram

    2016-08-01

    Current guidelines of the European Society of Medical Oncology recommend surgical excision biopsies of lymph nodes for the diagnosis of lymphoma whenever possible. However, core needle biopsies are increasingly used. We aimed to understand the common practice to choose the method of biopsy in Germany. Furthermore, we wanted to understand performance of surgical excision and core needle biopsies of lymph nodes in the diagnosis of lymphoma. The files of 1510 unselected, consecutive lymph node specimens from a consultation center for lymphoma diagnosis were analyzed. Core needle biopsies were obtained frequently from lymph nodes localized in mediastinal, abdominal, retroperitoneal, or thoracic regions. Patients undergoing core needle biopsies were significantly older and suffered significantly more often from lymphoma than patients undergoing surgical excision biopsies. Although more immunohistochemical tests were ordered by the pathologist for core needle biopsies specimens than for surgical excision biopsies specimens, core needle biopsies did not yield a definite diagnosis in 8.3 % of cases, compared to 2.8 % for SEB (p = 0.0003). Restricting the analysis to cases with a final diagnosis of follicular lymphoma or diffuse large B-cell lymphoma, core needle biopsies identified a simultaneous low- and high-grade lymphoma (transformation) in 3.3 % of cases, compared to 7.6 % for surgical excision biopsies (p = 0.2317). In Germany, core needle biopsies are preferentially used in elderly patients with a high likelihood of suffering from lymphoma. Core needle appeared inferior to surgical excision biopsies at providing a definite diagnosis and at identifying multiple lymphoma differentiations and transformation. PMID:27236576

  18. Core needle biopsies and surgical excision biopsies in the diagnosis of lymphoma-experience at the Lymph Node Registry Kiel.

    PubMed

    Johl, Alice; Lengfelder, Eva; Hiddemann, Wolfgang; Klapper, Wolfram

    2016-08-01

    Current guidelines of the European Society of Medical Oncology recommend surgical excision biopsies of lymph nodes for the diagnosis of lymphoma whenever possible. However, core needle biopsies are increasingly used. We aimed to understand the common practice to choose the method of biopsy in Germany. Furthermore, we wanted to understand performance of surgical excision and core needle biopsies of lymph nodes in the diagnosis of lymphoma. The files of 1510 unselected, consecutive lymph node specimens from a consultation center for lymphoma diagnosis were analyzed. Core needle biopsies were obtained frequently from lymph nodes localized in mediastinal, abdominal, retroperitoneal, or thoracic regions. Patients undergoing core needle biopsies were significantly older and suffered significantly more often from lymphoma than patients undergoing surgical excision biopsies. Although more immunohistochemical tests were ordered by the pathologist for core needle biopsies specimens than for surgical excision biopsies specimens, core needle biopsies did not yield a definite diagnosis in 8.3 % of cases, compared to 2.8 % for SEB (p = 0.0003). Restricting the analysis to cases with a final diagnosis of follicular lymphoma or diffuse large B-cell lymphoma, core needle biopsies identified a simultaneous low- and high-grade lymphoma (transformation) in 3.3 % of cases, compared to 7.6 % for surgical excision biopsies (p = 0.2317). In Germany, core needle biopsies are preferentially used in elderly patients with a high likelihood of suffering from lymphoma. Core needle appeared inferior to surgical excision biopsies at providing a definite diagnosis and at identifying multiple lymphoma differentiations and transformation.

  19. Sentinel lymph node biopsy in breast cancer

    PubMed Central

    Alsaif, Abdulaziz A.

    2015-01-01

    Objectives: To report our experience in sentinel lymph node biopsy (SLNB) in early breast cancer. Methods: This is a retrospective study conducted at King Khalid University Hospital, Riyadh, Kingdom of Saudi Arabia between January 2005 and December 2014. There were 120 patients who underwent SLNB with frozen section examination. Data collected included the characteristics of patients, index tumor, and sentinel node (SN), SLNB results, axillary recurrence rate and SLNB morbidity. Results: There were 120 patients who had 123 cancers. Sentinel node was identified in 117 patients having 120 tumors (97.6% success rate). No SN was found intraoperatively in 3 patients. Frozen section results showed that 95 patients were SN negative, those patients had no immediate axillary lymph node dissection (ALND), whereas 25 patients were SN positive and subsequently had immediate ALND. Upon further examination of the 95 negative SN’s by hematoxylin & eosin (H&E) and immunohistochemical staining for doubtful H&E cases, 10 turned out to have micrometastases (6 had delayed ALND and 4 had no further axillary surgery). Median follow up of patients was 35.5 months and the mean was 38.8 months. There was one axillary recurrence observed in the SN negative group. The morbidity of SLNB was minimal. Conclusion: The obtainable results from our local experience in SLNB in breast cancer, concur with that seen in published similar literature in particular the axillary failure rate. Sentinel lymph node biopsy resulted in minimal morbidity. PMID:26318461

  20. Combination of needle aspiration and core needle biopsy: A new technique of stereotactic biopsy

    PubMed Central

    Wani, Abrar Ahad; Wani, M. Afzal; Ramzan, Altaf U.; Nizami, Furqan A.; Malik, Nayil K.; Shafiq, S.; Ahmad, Rais; Kumar, Ashish; Lone, Iqbal; Makhdoomi, Rumana

    2016-01-01

    Aim: The study aims at describing the results of using a new technique to acquire the tissue sample in stereotactic biopsy of brain lesions. Materials and Methods: The study was performed in 19 patients over a period of 5 years in which we used the new technique, i.e., Abrar and Afzal technique (AT) of obtaining tissue biopsy. It is a combination of core tissue biopsy and needle aspiration techniques. The technique was devised to acquire greater amount of tissue for pathologic study. Results: While we could give pathologic diagnosis in 18 patients out of 19 (94.7%), in one patient, the tissue sample revealed only inflammatory cells and definitive diagnosis could not be reached. There was no significant morbidity or any mortality in the series. Conclusion: Abrar and Afzal technique is a reasonably accurate technique of acquiring larger tissue sample in stereotactic brain biopsy without any additional risks. It can be done with little modification of the conventional equipment available with the stereotactic system. PMID:27057212

  1. A Combined Scintimammography/Stereotactic Core Biopsy Digital X-ray System

    SciTech Connect

    A. G. Weisenberger; F. Barbosa; T. D. Green; R. Hoefer; C. Keppel; B. Kross; S. Majewski; V. Popov; R. Wojcik; D. C. Wymer

    2000-10-20

    Jefferson Lab, Hampton University and the Riverside Regional Medical Center are collaborating in a clinical study employing a dual modality imaging system utilizing scintimammography and digital radiography. The purpose of the study is to obtain clinical data on the reliability of scintimammography in predicting the malignancy of suspected breast lesions with the ultimate goal to reduce the number of false positives associated with conventional x-ray mammography. The scintimammography gamma camera is a custom built mini gamma camera with an active area of 5.3 cm x 5.3 cm based on a 2x2 array of Hamamatsu R7600-C8 position sensitive photomultiplier tubes. The spatial resolution of the gamma camera at the collimator surface is <4 mm FWHM and the sensitivity is 4000 cps/mCi. Preliminary results are that of the six cases that indicated a lesion with high uptake of MiraLuma ({sup 99m}Tc-sestamibi) five were positive for cancer. Out of a total of 25 patients in the study, all cases negative for MiraLuma uptake were confirmed negative via the biopsy pathology. The scintimammography results indicate that the lesions become visible with the mini gamma camera within 3 minutes post injection of MiraLuma.

  2. Computer-simulated biopsy marking system for endoscopic surveillance of gastric lesions: a pilot study.

    PubMed

    Hu, Weiling; Wang, Bin; Sun, Leimin; Chen, Shujie; Wang, Liangjing; Wang, Kan; Wu, Jiaguo; Kim, John J; Liu, Jiquan; Dai, Ning; Duan, Huilong; Si, Jianmin

    2015-01-01

    Endoscopic tattoo with India ink injection for surveillance of premalignant gastric lesions is technically cumbersome and may not be durable. The aim of the study is to evaluate the accuracy of a novel, computer-simulated biopsy marking system (CSBMS) developed for the endoscopic marking of gastric lesions. Twenty-five patients with history of gastric intestinal metaplasia received both CSBMS-guided marking and India ink injection in five points in the stomach at index endoscopy. A second endoscopy was performed at three months. Primary outcome was accuracy of CSBMS (distance between CSBMS probe-guided site and tattoo site measured by CSBMS). The mean accuracy of CSBMS at angularis was 5.3 ± 2.2 mm, antral lesser curvature 5.7 ± 1.4 mm, antral greater curvature 6.1 ± 1.1 mm, antral anterior wall 6.9 ± 1.6 mm, and antral posterior wall 6.9 ± 1.6 mm. CSBMS (2.3 ± 0.9 versus 12.5 ± 4.6 seconds; P = 0.02) required less procedure time compared to endoscopic tattooing. No adverse events were encountered. CSBMS accurately identified previously marked gastric sites by endoscopic tattooing within 1 cm on follow-up endoscopy. PMID:25954747

  3. Temporal artery biopsy: is there any value in examining biopsies at multiple levels?

    PubMed Central

    Chakrabarty, A; Franks, A

    2000-01-01

    Aims—To analyse the cost-effectiveness of three strategies for examining temporal artery biopsies based on data from cases examined over the past 10 years. Methods—Of a total of 172 temporal artery biopsies, five were unsuitable for further analysis, 47 had already had levels cut, and 120 had levels cut as part of the study. All the biopsies were examined blind before and after levels. A tree with eventual diagnostic outcomes for different strategies was constructed and economic and sensitivity analyses performed. Welcan units were used to assess technical workload. Results—Only one of the 132 initially normal cases and two of 14 diagnosed with periarterial lymphocytic infiltration (PALI) revealed giant cell arteritis after examining the tissue at multiple levels. Fifteen cases (8.9%) showed PALI not previously observed. The marginal cost for each extra case of giant cell arteritis detected was 83.5 Welcan units for a strategy of routine levels on all sections, and 21 Welcan units for a strategy of only cutting levels if PALI was present on the initial section. These costs were sensitive to the frequency of giant cell arteritis in cases with PALI and to the relative extra cost of moving from cutting single section to routine levels. Conclusions—Routinely examining a temporal artery biopsy at multiple levels does not increase the diagnostic yield of the test, although selective further examination may be indicated in some cases. The significance of PALI is uncertain. The cost-benefit of the different strategies in terms of clinical decision making revolve around the perceived risk inherent in not making a diagnosis of giant cell arteritis. Key Words: temporal artery biopsy • economic analysis • decision analysis PMID:10767829

  4. Direct MRI-guided biopsy of the prostate: use of post-biopsy needle track imaging to confirm targeting

    PubMed Central

    Nicholson, Alexander J.; Pettersson, David R.; Korngold, Elena K.; Foster, Bryan R.; Hung, Arthur Y.; Amling, Christopher L.; Coakley, Fergus V.

    2015-01-01

    Purpose To report the observation that in-plane post-biopsy T2-weighted MRI often demonstrates the needle track as a transient visible linear tissue distortion during direct MRI-guided biopsy. Materials and methods We retrospectively identified 11 prostatic lesions in 9 men that underwent direct MRI-guided biopsy and in which post-biopsy images were obtained in the plane of the biopsy needle. Results In 9 of 11 targets, a post-biopsy needle track was visible as a linear tissue distortion on in-plane T2-weighted images obtained at a mean interval of 6 min (range 3–15). In these nine cases, the needle track traversed the intended target, and the biopsy was positive for malignancy in six. Biopsy was positive in one of two cases where the needle track was not visible. In five targets, one or more delayed series were obtained after a mean interval of 21 min (range 8–33), showing the track was no longer visible (n = 3) or was of progressively decreased conspicuity (n = 2). Conclusion Accurate targeting during direct MRI-guided biopsy of the prostate can be confirmed by obtaining post-biopsy in-plane images, since the needle track is usually visible as a transient linear tissue distortion. PMID:25687631

  5. A novel in vitro bovine cartilage punch model for assessing the regeneration of focal cartilage defects with biocompatible bacterial nanocellulose

    PubMed Central

    2013-01-01

    Introduction Current therapies for articular cartilage defects fail to achieve qualitatively sufficient tissue regeneration, possibly because of a mismatch between the speed of cartilage rebuilding and the resorption of degradable implant polymers. The present study focused on the self-healing capacity of resident cartilage cells in conjunction with cell-free and biocompatible (but non-resorbable) bacterial nanocellulose (BNC). This was tested in a novel in vitro bovine cartilage punch model. Methods Standardized bovine cartilage discs with a central defect filled with BNC were cultured for up to eight weeks with/without stimulation with transforming growth factor-β1 (TGF-β1. Cartilage formation and integrity were analyzed by histology, immunohistochemistry and electron microscopy. Content, release and neosynthesis of the matrix molecules proteoglycan/aggrecan, collagen II and collagen I were also quantified. Finally, gene expression of these molecules was profiled in resident chondrocytes and chondrocytes migrated onto the cartilage surface or the implant material. Results Non-stimulated and especially TGF-β1-stimulated cartilage discs displayed a preserved structural and functional integrity of the chondrocytes and surrounding matrix, remained vital in long-term culture (eight weeks) without signs of degeneration and showed substantial synthesis of cartilage-specific molecules at the protein and mRNA level. Whereas mobilization of chondrocytes from the matrix onto the surface of cartilage and implant was pivotal for successful seeding of cell-free BNC, chondrocytes did not immigrate into the central BNC area, possibly due to the relatively small diameter of its pores (2 to 5 μm). Chondrocytes on the BNC surface showed signs of successful redifferentiation over time, including increase of aggrecan/collagen type II mRNA, decrease of collagen type I mRNA and initial deposition of proteoglycan and collagen type II in long-term high-density pellet cultures

  6. Patient Outcomes in Canceled MRI-Guided Breast Biopsies

    PubMed Central

    Niell, Bethany L.; Lee, Janie M.; Johansen, Christopher; Halpern, Elkan F.; Rafferty, Elizabeth A.

    2013-01-01

    OBJECTIVE. The reported frequency of aborted MRI-guided breast biopsies ranges from 8% to 17%, usually secondary to nonvisualization at attempted biopsy. Our study examines the frequency of MRI-guided breast biopsies aborted because of lesion nonvisualization and the subsequent risk of malignancy. MATERIALS AND METHODS. We identified 350 patients and 445 lesions scheduled for MRI-guided biopsy between January 1, 2007, and December 31, 2009. Medical records and imaging studies were reviewed to ascertain patient demographics, lesion and imaging characteristics, and subsequent pathology results. Chi-square statistics were calculated for patient level analyses. RESULTS. MRI-guided biopsies were aborted in 13% (56/445) of lesions and 15% (53/350; 95% CI, 11.6–19.3%) of patients because of nonvisualization of the biopsy target at the time of attempted biopsy. Of these 53 patients, 50 patients had follow-up data available. Malignancy was subsequently diagnosed in five of those 50 patients (10%; 95% CI, 3.3–21.8%) patients, three with invasive ductal carcinomas and two with ductal carcinoma in situ. The mean time to malignant diagnosis from the date of aborted biopsy was 2.6 months (range, 1.1–6.9 months). CONCLUSION. Informed consent for MRI-guided breast biopsies should include discussion of biopsy cancellation because of nonvisualization of the target lesion. The low yet significant risk of malignancy in patients subsequent to an aborted MRI-guided breast biopsy warrants short-term follow-up MRI after a canceled biopsy. PMID:24370148

  7. Diagnostic yield of brain biopsies in children presenting to neurology.

    PubMed

    Venkateswaran, Sunita; Hawkins, Cynthia; Wassmer, Evangeline

    2008-03-01

    The role of brain biopsy is well established in patients with neoplastic lesions, with a diagnostic yield approaching 95%. The diagnostic yield of brain biopsy in adults with neurological decline varies from 20% to 43%. Only a few studies have examined the diagnostic yield of brain biopsy in children with idiopathic neurological decline. A retrospective analysis was conducted on all open and closed pediatric brain biopsies performed between January 1988 and May 2003. Biopsies were performed for diagnostic purposes in patients showing a progressively deteriorating neurologic course in whom less-invasive modalities such as neuroimaging, electroencephalography (EEG), and molecular genetic studies were either negative or inconclusive. Immunocompromised patients were included. Patients were excluded if the preoperative diagnosis was a neoplasm or if the patient was undergoing a resection as part of a work-up for intractable epilepsy. Each patient underwent numerous investigations before brain biopsy. The utility of each biopsy was analyzed. Sixty-six children had brain biopsies performed for diagnostic purposes during the study period. Patient ages ranged from 2 months to 16 years and 9 months at the time of biopsy. The diagnostic yield was 48.5% overall, with a yield of 68.8% between 1996 and 2003. Of the total, 26 (39.4%) biopsies were both diagnostic and useful. Patients most frequently presented with seizures (56.1%) and encephalopathy (33%). The most frequently diagnosed disease was vasculitis (18.2%). A total of 71.9% of patients with diagnostic biopsies improved with appropriate treatment. Brain biopsy in children had a diagnostic yield of 48.5% in our series. A specific diagnosis may help in management and outcome, especially with a diagnosis of vasculitis. PMID:18192645

  8. Microfabricated instrument for tissue biopsy and analysis

    DOEpatents

    Krulevitch, Peter A.; Lee, Abraham P.; Northrup, M. Allen; Benett, William J.

    2001-01-01

    A microfabricated biopsy/histology instrument which has several advantages over the conventional procedures, including minimal specimen handling, smooth cutting edges with atomic sharpness capable of slicing very thin specimens (approximately 2 .mu.m or greater), micro-liter volumes of chemicals for treating the specimens, low cost, disposable, fabrication process which renders sterile parts, and ease of use. The cutter is a "cheese-grater" style design comprising a block or substrate of silicon and which uses anisotropic etching of the silicon to form extremely sharp and precise cutting edges. As a specimen is cut, it passes through the silicon cutter and lies flat on a piece of glass which is bonded to the cutter. Microchannels are etched into the glass or silicon substrates for delivering small volumes of chemicals for treating the specimen. After treatment, the specimens can be examined through the glass substrate.

  9. Intrinsic Frequency and the Single Wave Biopsy

    PubMed Central

    Petrasek, Danny; Pahlevan, Niema M.; Tavallali, Peyman; Rinderknecht, Derek G.; Gharib, Morteza

    2015-01-01

    Insulin resistance is the hallmark of classical type II diabetes. In addition, insulin resistance plays a central role in metabolic syndrome, which astonishingly affects 1 out of 3 adults in North America. The insulin resistance state can precede the manifestation of diabetes and hypertension by years. Insulin resistance is correlated with a low-grade inflammatory condition, thought to be induced by obesity as well as other conditions. Currently, the methods to measure and monitor insulin resistance, such as the homeostatic model assessment and the euglycemic insulin clamp, can be impractical, expensive, and invasive. Abundant evidence exists that relates increased pulse pressure, pulse wave velocity (PWV), and vascular dysfunction with insulin resistance. We introduce a potential method of assessing insulin resistance that relies on a novel signal-processing algorithm, the intrinsic frequency method (IFM). The method requires a single pulse pressure wave, thus the term “ wave biopsy.” PMID:26183600

  10. Automated quantitative muscle biopsy analysis system

    NASA Technical Reports Server (NTRS)

    Castleman, Kenneth R. (Inventor)

    1980-01-01

    An automated system to aid the diagnosis of neuromuscular diseases by producing fiber size histograms utilizing histochemically stained muscle biopsy tissue. Televised images of the microscopic fibers are processed electronically by a multi-microprocessor computer, which isolates, measures, and classifies the fibers and displays the fiber size distribution. The architecture of the multi-microprocessor computer, which is iterated to any required degree of complexity, features a series of individual microprocessors P.sub.n each receiving data from a shared memory M.sub.n-1 and outputing processed data to a separate shared memory M.sub.n+1 under control of a program stored in dedicated memory M.sub.n.

  11. [Conjunctival rhinosporidiois diagnosed in a biopsy specimen].

    PubMed

    Zoroquiain, Pablo; Moreno, Alberto; Oddó, David

    2014-04-01

    11 years old girl, from south region of Chile, without history of travels outside Chile nor the province, complaints of red eye with blepharitis and blood-tingued epiphora. Eye exam revealed a pseudomembrane. Clinical diagnosis was folicular conjunctivitis. A surgical removal was performed and the lesion sent to biopsy analysis. On microscopic examination numerous 50-150 microm cysts with keratinous wall and numerous endospores were found. Rinosporidiosis is an infection caused by Rhinosporidium seeberi that frecuently affects nasal cavity but could infect eye, urogenital tract and airways. This infections is considered endemic in Asia and Africa, but it is very important to have the suspicious among polyps in these areas because travel to endemic areas is become more frecuently. PMID:24878912

  12. Percutaneous renal biopsy as an outpatient procedure.

    PubMed Central

    Alebiosu, Christopher O.; Kadiri, Solomon

    2004-01-01

    Percutaneous renal biopsy (PRB) is a safe and effective tool in the diagnosis and management of renal disease. It is the gold standard for evaluating renal parenchymal disease. It is both useful for diagnosis and monitoring progress of renal diseases. Where facilities and personnel are available to carry out the procedure in developing countries, it has become increasingly difficult for patients to pay for hospital admission fees, the procedure, and processing of the samples obtained. Information on the success rate and safety of the procedure is of interest to nephrologists for cost-benefit considerations and medicolegal purposes. This paper reports the outcome of outpatient PRB done among patients of the University College Hospital, Ibadan, Nigeria. With the use of ultrasound guidance, PRB remains a safe procedure and can be done on an outpatient basis. PMID:15481751

  13. Small punch tensile/fracture test data and 3D specimen surface data on Grade 91 ferritic/martensitic steel from cryogenic to room temperature.

    PubMed

    Bruchhausen, Matthias; Lapetite, Jean-Marc; Ripplinger, Stefan; Austin, Tim

    2016-12-01

    Raw data from small punch tensile/fracture tests at two displacement rates in the temperature range from -196 °C to room temperature on Grade 91 ferritic/martensitic steel are presented. A number of specimens were analyzed after testing by means of X-ray computed tomography (CT). Based on the CT volume data detailed 3D surface maps of the specimens were established. All data are open access and available from Online Data Information Network (ODIN)https://odin.jrc.ec.europa.eu. The data presented in the current work has been analyzed in the research article "On the determination of the ductile to brittle transition temperature from small punch tests on Grade 91 ferritic-martensitic steel" (M. Bruchhausen, S. Holmström, J.-M. Lapetite, S. Ripplinger, 2015) [1].

  14. Small punch tensile/fracture test data and 3D specimen surface data on Grade 91 ferritic/martensitic steel from cryogenic to room temperature.

    PubMed

    Bruchhausen, Matthias; Lapetite, Jean-Marc; Ripplinger, Stefan; Austin, Tim

    2016-12-01

    Raw data from small punch tensile/fracture tests at two displacement rates in the temperature range from -196 °C to room temperature on Grade 91 ferritic/martensitic steel are presented. A number of specimens were analyzed after testing by means of X-ray computed tomography (CT). Based on the CT volume data detailed 3D surface maps of the specimens were established. All data are open access and available from Online Data Information Network (ODIN)https://odin.jrc.ec.europa.eu. The data presented in the current work has been analyzed in the research article "On the determination of the ductile to brittle transition temperature from small punch tests on Grade 91 ferritic-martensitic steel" (M. Bruchhausen, S. Holmström, J.-M. Lapetite, S. Ripplinger, 2015) [1]. PMID:27660812

  15. Needle aspiration biopsy in salivary gland lesions.

    PubMed

    Shaha, A R; Webber, C; DiMaio, T; Jaffe, B M

    1990-10-01

    The value of needle aspiration biopsy in the evaluation and management of salivary gland pathology is controversial. The major reasons for this controversy are the difficulty in cytologic evaluation and the fact that the extent of surgery can be easily defined based on clinical judgement. However, a preoperative diagnosis is helpful in discussions with patients regarding the extent and type of surgery. Apart from the fact that needle biopsy can distinguish benign from malignant conditions, it is also very useful in distinguishing between salivary and other nonsalivary pathology. Over the past 7 1/2 years, we have performed 160 needle aspirations of parotid, submandibular, and submucosal lesions. Adequate specimens for cytologic evaluation were obtained in 155 patients (97%). A total of 84 parotid lesions, 70 submandibular lumps, and 6 submucosal abnormalities were detected. A cytologic diagnosis of benign pathology was made in 120 patients. Twelve patients had lymphoma and the diagnosis was suspected based on needle aspiration. There were 10 patients with tuberculosis and 30 patients with hyperplastic lymph nodes or benign lymphoepithelial disease of the parotid. There were three false-positive and two false-negative reports. No complications such as hematoma, nerve injury, or infection developed. The major difficulty was in distinguishing between malignancy and obstructive sialadenitis in the submandibular region. Needle aspiration was helpful in evaluating lesions in the tail of the parotid and submandibular area. The cytologic distinction between salivary and nonsalivary pathology was useful in planning the appropriate surgery and the extent of surgical resection. From a clinical standpoint, the distinction between benign and malignant salivary and nonsalivary pathology was very helpful. Preoperative diagnosis of Warthin's tumor, lymphoma, or benign lymphoepithelial disease was essential to the correct management of these patients.

  16. Preservative solution for skeletal muscle biopsy samples

    PubMed Central

    Kurt, Yasemin Gulcan; Kurt, Bulent; Ozcan, Omer; Topal, Turgut; Kilic, Abdullah; Muftuoglu, Tuba; Acikel, Cengizhan; Sener, Kenan; Sahiner, Fatih; Yigit, Nuri; Aydin, Ibrahim; Alay, Semih; Ekinci, Safak

    2015-01-01

    Context: Muscle biopsy samples must be frozen with liquid nitrogen immediately after excision and maintained at -80°C until analysis. Because of this requirement for tissue processing, patients with neuromuscular diseases often have to travel to centers with on-site muscle pathology laboratories for muscle biopsy sample excision to ensure that samples are properly preserved. Aim: Here, we developed a preservative solution and examined its protectiveness on striated muscle tissues for a minimum of the length of time that would be required to reach a specific muscle pathology laboratory. Materials and Methods: A preservative solution called Kurt-Ozcan (KO) solution was prepared. Eight healthy Sprague-Dawley rats were sacrificed; striated muscle tissue samples were collected and divided into six different groups. Muscle tissue samples were separated into groups for morphological, enzyme histochemical, molecular, and biochemical analysis. Statistical method used: Chi-square and Kruskal Wallis tests. Results: Samples kept in the KO and University of Wisconsin (UW) solutions exhibited very good morphological scores at 3, 6, and 18 hours, but artificial changes were observed at 24 hours. Similar findings were observed for the evaluated enzyme activities. There were no differences between the control group and the samples kept in the KO or UW solution at 3, 6, and 18 hours for morphological, enzyme histochemical, and biochemical features. The messenger ribonucleic acid (mRNA) of β-actin gene was protected up to 6 hours in the KO and UW solutions. Conclusion: The KO solution protects the morphological, enzyme histochemical, and biochemical features of striated muscle tissue of healthy rats for 18 hours and preserves the mRNA for 6 hours. PMID:26019417

  17. Efficacy of Punch Elevation Combined with Fractional Carbon Dioxide Laser Resurfacing in Facial Atrophic Acne Scarring: A Randomized Split-face Clinical Study

    PubMed Central

    Faghihi, Gita; Nouraei, Saeid; Asilian, Ali; Keyvan, Shima; Abtahi-Naeini, Bahareh; Rakhshanpour, Mehrdad; Nilforoushzadeh, Mohammad Ali; Hosseini, Sayed Mohsen

    2015-01-01

    Background: A number of treatments for reducing the appearance of acne scars are available, but general guidelines for optimizing acne scar treatment do not exist. The aim of this study was to compare the clinical effectiveness and side effects of fractional carbon dioxide (CO2) laser resurfacing combined with punch elevation with fractional CO2 laser resurfacing alone in the treatment of atrophic acne scars. Materials and Methods: Forty-two Iranian subjects (age range 18–55) with Fitzpatrick skin types III to IV and moderate to severe atrophic acne scars on both cheeks received randomized split-face treatments: One side received fractional CO2 laser treatment and the other received one session of punch elevation combined with two sessions of laser fractional CO2 laser treatment, separated by an interval of 1 month. Two dermatologists independently evaluated improvement in acne scars 4 and 16 weeks after the last treatment. Side effects were also recorded after each treatment. Results: The mean ± SD age of patients was 23.4 ± 2.6 years. Clinical improvement of facial acne scarring was assessed by two dermatologists blinded to treatment conditions. No significant difference in evaluation was observed 1 month after treatment (P = 0.56). Their evaluation found that fractional CO2 laser treatment combined with punch elevation had greater efficacy than that with fractional CO2 laser treatment alone, assessed 4 months after treatment (P = 0.02). Among all side effects, coagulated crust formation and pruritus at day 3 after fractional CO2 laser treatment was significant on both treatment sides (P < 0.05). Conclusion: Concurrent use of fractional laser skin resurfacing with punch elevation offers a safe and effective approach for the treatment of acne scarring. PMID:26538695

  18. Comparison of MR/Ultrasound Fusion–Guided Biopsy With Ultrasound-Guided Biopsy for the Diagnosis of Prostate Cancer

    PubMed Central

    Siddiqui, M. Minhaj; Rais-Bahrami, Soroush; Turkbey, Baris; George, Arvin K.; Rothwax, Jason; Shakir, Nabeel; Okoro, Chinonyerem; Raskolnikov, Dima; Parnes, Howard L.; Linehan, W. Marston; Merino, Maria J.; Simon, Richard M.; Choyke, Peter L.; Wood, Bradford J.; Pinto, Peter A.

    2015-01-01

    Importance Targeted magnetic resonance (MR)/ultrasound fusion prostate biopsy has been shown to detect prostate cancer. The implications of targeted biopsy alone vs standard extended-sextant biopsy or the 2 modalities combined are not well understood. Objective To assess targeted vs standard biopsy and the 2 approaches combined for the diagnosis of intermediate- to high-risk prostate cancer. Design, Setting, And Participants Prospective cohort study of 1003 men undergoing both targeted and standard biopsy concurrently from 2007 through 2014 at the National Cancer Institute in the United States. Patients were referred for elevated level of prostate-specific antigen (PSA) or abnormal digital rectal examination results, often with prior negative biopsy results. Risk categorization was compared among targeted and standard biopsy and, when available, whole-gland pathology after prostatectomy as the “gold standard.” Interventions Patients underwent multiparametric prostate magnetic resonance imaging to identify regions of prostate cancer suspicion followed by targeted MR/ultrasound fusion biopsy and concurrent standard biopsy. Main Outcomes And Measures The primary objective was to compare targeted and standard biopsy approaches for detection of high-risk prostate cancer (Gleason score ≥4 + 3); secondary end points focused on detection of low-risk prostate cancer (Gleason score 3 + 3 or low-volume 3 + 4) and the biopsy ability to predict whole-gland pathology at prostatectomy. Results Targeted MR/ultrasound fusion biopsy diagnosed 461 prostate cancer cases, and standard biopsy diagnosed 469 cases. There was exact agreement between targeted and standard biopsy in 690 men (69%) undergoing biopsy. Targeted biopsy diagnosed 30% more high-risk cancers vs standard biopsy (173 vs 122 cases, P < .001) and 17% fewer low-risk cancers (213 vs 258 cases, P < .001). When standard biopsy cores were combined with the targeted approach, an additional 103 cases (22%) of mostly low

  19. Characterization of mechanical properties of aluminized coatings in advanced gas turbine blades using a small punch method

    SciTech Connect

    Sugita, Y.; Ito, M.; Sakurai, S.; Bloomer, T.E.; Kameda, J. |

    1997-04-01

    Advanced technologies of superalloy casting and coatings enable one to enhance the performance of combined cycle gas turbines for electric power generation by increasing the firing temperature. This paper describes examination of the microstructure/composition and mechanical properties (22--950 C) in aluminized CoCrAlY coatings of advanced gas turbine blades using scanning Auger microprobe and a small punch (SP) testing method. Aluminized coatings consisted of layered structure divided into four regimes: (1) Al enriched and Cr depleted region, (2) Al and Cr graded region, (3) fine grained microstructure with a mixture of Al and Cr enriched phases and (4) Ni/Co interdiffusion zone adjacent to the interface. SP specimens were prepared in order that the specimen surface would be located in the various coating regions. SP tests indicated strong dependence of the fracture properties on the various coatings regimes. Coatings 1 and 2 with very high microhardness showed much easier formation of brittle cracks in a wide temperature range, compared to coatings 3 and 4 although the coating 2 had ductility improvement at 950 C. The coating 3 had lower room temperature ductility than the coating 4. However, the ductility in the coating 3 exceeded that in the region 4 above 730 C due to a precipitous ductility increase. The integrity of aluminized coatings while in-service is discussed in light of the variation of the low cycle fatigue life as well as the ductility in the layered structure.

  20. Operating manual for the U.S. Geological Survey minimonitor, 1988 revised edition; punched-paper-tape model

    USGS Publications Warehouse

    Ficken, James H.; Scott, Carl T.

    1988-01-01

    This manual describes the U.S. Geological Survey Minimonitor Water Quality Data Measuring and Recording System. Instructions for calibrating, servicing, maintaining, and operating the system are provided. The Survey Minimonitor is a battery-powered , multiparameter water quality monitoring instrument designed for field use. A watertight can containing signal conditioners is connected with cable and waterproof connectors to various water quality sensors. Data are recorded on a punched paper-tape recorder. An external battery is required. The operation and maintenance of various sensors and signal conditioners are discussed, for temperature, specific conductance, dissolved oxygen, and pH. Calibration instructions are provided for each parameter, along with maintenance instructions. Sections of the report explain how to connect the Minimonitor to measure direct-current voltages, such as signal outputs from other instruments. Instructions for connecting a satellite data-collection platform or a solid-state data recorder to the Minimonitor are given also. Basic information is given for servicing the Minimonitor and trouble-shooting some of its electronic components. The use of test boxes to test sensors, isolate component problems, and verify calibration values is discussed. (USGS)

  1. Real-time ultrasound-guided percutaneous renal biopsy with needle guide by nephrologists decreases post-biopsy complications

    PubMed Central

    Prasad, Narayan; Kumar, Shashi; Manjunath, Revanasiddappa; Bhadauria, Dharmendra; Kaul, Anupama; Sharma, Raj K; Gupta, Amit; Lal, Hira; Jain, Manoj; Agrawal, Vinita

    2015-01-01

    Background Percutaneous renal biopsy (PRB) can result in serious complications. The study is aimed to compare the biopsy yield and complications rate of the real-time ultrasonagram (USG)-guided PRB and needle tracking with and without needle guide in two different study periods. Methods We compared the yield and complications of 2138 kidney biopsies performed in two different periods, 1510 biopsies during the first period from April 2004–December 2010 and 628 biopsies during second period from January 2011–March 2013. All biopsies in both periods were performed by nephrologists. Radiologists provided the real-time image without needle guide during the first period while nephrologists performed both imaging and biopsy with needle guide during the second period. Results Of all the 2138 patients, 226 (10.5%) patients developed 118 minor and 108 major complications. Only 13 (2.1%) major complications occurred in the second period and 95 (6.7%) in the first period (P < 0.001). The relative risk of developing a major complication without guide was 3.04 times greater than that of the biopsies performed with use of the guide. The mean number of glomeruli per biopsy obtained during the second period (17.98 ± 6.75) was significantly greater than that of the first period (14.14 ± 6.01) (P = 0.004). The number of passes to acquire adequate tissue (P = 0.001) and percentage of cortex on biopsy (P = 0.001) were also significantly better in the second period. The optimal observation period post biopsy is 24 h. Conclusions Real-time USG imaging supported by needle guide device is associated with better biopsy yield and fewer complications. PMID:25815170

  2. Automatic biopsy instruments used through a coaxial bone biopsy system with an eccentric drill tip.

    PubMed

    Aström, K G; Sundström, J C; Lindgren, P G; Ahlström, K H

    1995-05-01

    Twenty-eight consecutive CT (n = 23) or ultrasonographically (n = 5) guided biopsy procedures were performed on musculoskeletal lytic lesions covered (n = 13) or not covered (n = 15) with intact bone. Specimens were obtained by means of Biopty techniques (n = 27), i.e. Biopty and Monopty instruments, through different cannulas with normal or shortened needle-throws. Four out of 5 bone penetrations were successful with an Ostycut needle, and all 8 bone penetrations by a coaxial bone biopsy system with an eccentric drill. The eccentric drill makes a hole in the cortical bone larger than the diameter of the outer cannula of this system, making it easy to anchor the cannula and then coaxially insert a Biopty-Gun needle for example. The overall histopathological diagnostic accuracy of the Biopty techniques was 25/27 (92.6%).

  3. Is magnetic resonance/ultrasound fusion prostate biopsy better than systematic prostate biopsy? an updated meta- and trial sequential analysis

    PubMed Central

    Xie, Bo; Wang, Xiao; Zhu, Yi; Wang, Junyuan; Yu, Yasai; Zheng, Xiangyi; Liu, Ben; Xie, Liping

    2015-01-01

    We systematically reviewed the literature to determine whether Magnetic Resonance/Ultrasound (MR/US) fusion prostate biopsy is better than systematic biopsy for making a definitive diagnosis of prostate cancer. The two strategies were also compared for their ability to detect lesions with different degrees of suspicion on MRI and clinically significant prostate cancer, and the number of cores needed for diagnosis. The Cochrane Library, Embase, Web of Knowledge, and Medline were searched from inception until May 1, 2015. Meta-analysis was conducted via RevMan 5.2 software. Data was expressed as risk ratio (RR) and 95% confidence interval. Trial sequential analysis was used to assess risk of random errors. Fourteen trials were included, encompassing a total of 3105 participants. We found that MR/US fusion biopsy detected more prostate cancers than systematic biopsy (46.9% vs. 44.2%, p=0.03). In men with moderate/high MRI suspicion, MR/US fusion biopsy did better than systematic biopsy (RR = 1.46; p < 0.05) for making a diagnosis. Moreover, MR/US fusion biopsy detected more clinically significant cancers than systematic biopsy (RR = 1.19; p < 0.05). We recommend that MR/US fusion prostate biopsy be used to better detect prostate cancer, particularly in patients with moderate/high suspicion lesions on MRI. PMID:26498362

  4. Renal biopsy in the management of lupus nephritis during pregnancy.

    PubMed

    Chen, T K; Gelber, A C; Witter, F R; Petri, M; Fine, D M

    2015-02-01

    The differential diagnosis of proteinuria and hematuria in pregnancy is broad and includes active lupus nephritis. Identification of the correct diagnosis often has a profound therapeutic impact on not only the mother but also the fetus. To date, relatively few reports exist on the role of renal biopsy during pregnancy among women with systemic lupus erythematosus (SLE). We present a case series of 11 pregnant women with SLE who underwent a renal biopsy to evaluate a presumptive flare of lupus nephritis. The electronic medical record was retrospectively analyzed for pre-biopsy serum creatinine, proteinuria, hematuria, antinuclear antibodies (ANA), and antibodies to double-stranded DNA (anti-dsDNA); histologic findings on renal biopsy; and the clinical course of each mother and fetus. From 2001 to 2012, 11 pregnant women with SLE flares during pregnancy underwent a renal biopsy at an academic tertiary medical center. At the time of biopsy, median gestational age was 16 weeks (range 9 to 27), median serum creatinine was 0.6 mg/dl (interquartile range 0.5 to 0.9), six (55%) had hematuria, and all had proteinuria >500 mg/24 hours. Proliferative lupus nephritis was found in 10 (91%) of 11 biopsies (five with ISN/RPS Class III; five with ISN/RPS Class IV). All but one individual underwent a change in management guided by information gleaned from renal biopsy. No apparent biopsy-related complications occurred to mother or fetus. Three women elected to terminate their pregnancy; although many factors were involved, the findings on renal biopsy informed the decision-making process. Among the remaining cases, there were three pre-term deliveries, one fetus with complete heart block, one in utero demise, and one maternal death. Renal biopsy is helpful at informing the management of patients with lupus nephritis during pregnancy.

  5. Limitations of stereotactic biopsy in the initial management of gliomas.

    PubMed Central

    Jackson, R. J.; Fuller, G. N.; Abi-Said, D.; Lang, F. F.; Gokaslan, Z. L.; Shi, W. M.; Wildrick, D. M.; Sawaya, R.

    2001-01-01

    Stereotactic biopsy is often performed for diagnostic purposes before treating patients whose imaging studies highly suggest glioma. Indications cited for biopsy include diagnosis and/or the "inoperability" of the tumor. This study questions the routine use of stereotactic biopsy in the initial management of gliomas. At The University of Texas M. D. Anderson Cancer Center, we retrospectively reviewed a consecutive series of 81 patients whose imaging studies suggested glioma and who underwent stereotactic biopsy followed by craniotomy/resection (within 60 days) between 1993 and 1998. All relevant clinical and imaging information was reviewed, including computerized volumetric analysis of the tumors based on pre- and postoperative MRI. Stereotactic biopsy was performed at institutions other than M. D. Anderson in 78 (96%) of 81 patients. The majority of tumors were located either in eloquent brain (36 of 81 = 44%) or near-eloquent brain (41 of 81 = 51%), and this frequently was the rationale cited for performing stereotactic biopsy. Gross total resection (>95%) was achieved in 46 (57%) of 81 patients, with a median extent of resection of 96% for this series. Diagnoses based on biopsy or resection in the same patient differed in 40 (49%) of 82 cases. This discrepancy was reduced to 30 (38%) of 80 cases when the biopsy slides were reviewed preoperatively by each of three neuropathologists at M. D. Anderson. Major neurologic complications occurred in 10 (12.3%) of 81 surgical patients and 3 (3.7%) of 81 patients undergoing biopsy. Surgical morbidity was probably higher in our series than it would be for glioma patients in general because our patients represent a highly selected subset of glioma patients whose tumors present a technical challenge to remove. Stereotactic biopsy is frequently inaccurate in providing a correct diagnosis and is associated with additional risk and cost. If stereotactic biopsy is performed, expert neuropathology consultation should be sought

  6. PET-directed, 3D Ultrasound-guided prostate biopsy

    PubMed Central

    Fei, Baowei; Nieh, Peter T; Schuster, David M; Master, Viraj A

    2013-01-01

    Multimodatity imaging is a promising approach for improving prostate cancer detection and diagnosis. This article describes various concepts in PET-directed, ultrasound-guided biopsies and highlights a new PET/ultrasound fusion targeted biopsy system for prostate cancer detection. PMID:25392702

  7. Diagnosis of sarcoidosis by lip biopsy of minor salivary glands

    PubMed Central

    Tannenbaum, Hyman; Anderson, Larry G.; Rosenberg, Earle H.; Sheffer, Albert L.

    1974-01-01

    In two patients with bilateral parotid gland swelling of unknown etiology the diagnosis of sarcoidosis was established by lip biopsy of the minor salivary glands. This simple, innocuous biopsy procedure may prove useful in tissue documentation of sarcoidosis. ImagesFIG. 1 PMID:4442017

  8. Diffuse reflectance imaging: a tool for guided biopsy

    NASA Astrophysics Data System (ADS)

    Jayanthi, Jayaraj L.; Subhash, Narayanan; Manju, Stephen; Nisha, Unni G.; Beena, Valappil T.

    2012-01-01

    Accurate diagnosis of premalignant or malignant oral lesions depends on the quality of the biopsy, adequate clinical information and correct interpretation of the biopsy results. The major clinical challenge is to precisely locate the biopsy site in a clinically suspicious lesion. Dips due to oxygenated hemoglobin absorption have been noticed at 545 and 575 nm in the diffusely reflected white light spectra of oral mucosa and the intensity ratio R545/R575 has been found suited for early detection of oral pre-cancers. A multi-spectral diffuse reflectance (DR) imaging system has been developed consisting of an electron multiplying charge coupled device (EMCCD) camera and a liquid crystal tunable filter for guiding the clinician to an optimal biopsy site. Towards this DR images were recorded from 27 patients with potentially malignant lesions on their tongue (dorsal, lateral and ventral sides) and from 44 healthy controls at 545 and 575 nm with the DR imaging system. False colored ratio image R545/R575 of the lesion provides a visual discerning capability that helps in locating the most malignant site for biopsy. Histopathological report of guided biopsy showed that out of the 27 patients 16 were cancers, 9 pre-cancers and 2 lichen planus. In this clinical trial DR imaging has correctly guided 25 biopsy sites, yielding a sensitivity of 93% and a specificity of 98%, thereby establishing the potential of DR imaging as a tool for guided biopsy.

  9. Biopsy of the right adrenal gland by the transhepatic approach

    SciTech Connect

    Price, R.B.; Bernardino, M.E.; Berkman, W.A.; Sones, P.J. Jr.; Torres, W.E.

    1983-08-01

    A transhepatic computed-tomographic-guided biopsy of a right adrenal mass is described. This method is simpler to perform than the usual posterior biopsy carried out with the patient prone and is less likely to cause a complicating pneumothorax. In seven of eight patients with right adrenal masses, adrenal tissue was obtained and an accurate diagnosis was possible. No complications resulted.

  10. My approach to the interpretation of endometrial biopsies and curettings

    PubMed Central

    McCluggage, W G

    2006-01-01

    A major proportion of the workload in many histopathology laboratories is accounted for by endometrial biopsies, either curettage specimens or outpatient biopsy specimens. The increasing use of pipelle and other methods of biopsy not necessitating general anaesthesia has resulted in greater numbers of specimens with scant tissue, resulting in problems in assessing adequacy and in interpreting artefactual changes, some of which appear more common with outpatient biopsies. In this review, the criteria for adequacy and common artefacts in endometrial biopsies, as well as the interpretation of endometrial biopsies in general, are discussed, concentrating on areas that cause problems for pathologists. An adequate clinical history, including knowledge of the age, menstrual history and menopausal status, and information on the use of exogenous hormones and tamoxifen, is necessary for the pathologist to critically evaluate endometrial biopsies. Topics such as endometritis, endometrial polyps, changes that are induced by hormones and tamoxifen within the endometrium, endometrial metaplasias and hyperplasias, atypical polypoid adenomyoma, adenofibroma, adenosarcoma, histological types of endometrial carcinoma and grading of endometrial carcinomas are discussed with regard to endometrial biopsy specimens rather than hysterectomy specimens. The value of ancillary techniques, especially immunohistochemistry, is discussed where appropriate. PMID:16873562

  11. Percutaneous lung biopsy in the horse: comparison of two instruments and repeated biopsy in horses with induced acute interstitial pneumopathy.

    PubMed

    Venner, M; Schmidbauer, S; Drommer, W; Deegen, E

    2006-01-01

    The aim of the study reported here was to compare complications of lung biopsy in horses and the quality of the lung specimens after biopsy using the manual Tru-Cut biopsy needle (TC) and an automated biopsy needle (ABN). For experiment 1, lung biopsy was performed in 50 horses with one instrument on one side of the thorax, and then with the other instrument on the other side. Postmortem examination was performed in 20 of the 50 horses. Coughing was detected in 10 of 50 horses and epistaxis was observed in 6 of the 50 horses. Endoscopy revealed bleeding into the airways in 16 of 49 horses and in 5 of 49 horses after biopsy with the TC or the ABN, respectively. Use of the ABN induced a significantly smaller amount of bleeding. Pneumothorax was detected by radiography in 1 of 50 horses. Hematoma diameter determined in 7 of 20 horses at postmortem examination, was significantly larger after biopsy with the TC than with the ABN. The quality of the lung specimen was good. In experiment 2, complications after repeated and multiple lung biopsies in 6 horses were evaluated. Moderate epistaxis was observed on 13 of 104 occasions. Bleeding into the airways was detected at endoscopy on 41 of 104 occasions, and pneumothorax was detected during 4 of 104 occasions. Complications such as hematoma at the biopsy site and bleeding into the airways were greater after biopsy with the TC than after use of the ABN. Lung biopsy specimens obtained with the ABN were fairly safe for the animal.

  12. Recent advances in image-guided targeted prostate biopsy.

    PubMed

    Brown, Anna M; Elbuluk, Osama; Mertan, Francesca; Sankineni, Sandeep; Margolis, Daniel J; Wood, Bradford J; Pinto, Peter A; Choyke, Peter L; Turkbey, Baris

    2015-08-01

    Prostate cancer is a common malignancy in the United States that results in over 30,000 deaths per year. The current state of prostate cancer diagnosis, based on PSA screening and sextant biopsy, has been criticized for both overdiagnosis of low-grade tumors and underdiagnosis of clinically significant prostate cancers (Gleason score ≥7). Recently, image guidance has been added to perform targeted biopsies of lesions detected on multi-parametric magnetic resonance imaging (mpMRI) scans. These methods have improved the ability to detect clinically significant cancer, while reducing the diagnosis of low-grade tumors. Several approaches have been explored to improve the accuracy of image-guided targeted prostate biopsy, including in-bore MRI-guided, cognitive fusion, and MRI/transrectal ultrasound fusion-guided biopsy. This review will examine recent advances in these image-guided targeted prostate biopsy techniques. PMID:25596716

  13. The global burden of major infectious complications following prostate biopsy.

    PubMed

    Bennett, H Y; Roberts, M J; Doi, S A R; Gardiner, R A

    2016-06-01

    We present a systematic review providing estimates of the overall and regional burden of infectious complications following prostate biopsy. A directly standardized prevalence estimate was used because it reflects the burden of disease more explicitly. Complications included sepsis, hospitalization, bacteraemia, bacteriuria, and acute urinary retention after biopsy. There were 165 articles, comprising 162 577 patients, included in the final analysis. Our findings demonstrate that transrectal biopsy was associated with a higher burden of hospitalization (1·1% vs. 0·9%) and sepsis (0·8% vs. 0·1%) compared to transperineal biopsy, while acute urinary retention was more prevalent after transperineal than transrectal biopsy (4·2% vs. 0·9%). The differences were statistically non-significant because of large heterogeneity across countries. We also demonstrate and discuss regional variations in complication rates, with Asian studies reporting higher rates of sepsis and hospitalization.

  14. Aspiration biopsy of testis: another method for histologic examination

    SciTech Connect

    Nseyo, U.O.; Englander, L.S.; Huben, R.P.; Pontes, J.E.

    1984-08-01

    The most important method for evaluating the pathogenesis of male infertility is open testicular biopsy. Herein the authors describe a method of aspiration biopsy of testis for histologic examination. Sexually mature dogs and rats treated with chemotherapeutic agents and ionizing radiation were followed with periodic testicular aspiration biopsy during and after treatment. The histologic findings from the aspiration biopsy compare with the results of routine histologic examination in assessing spermatogenetic activity and delineating pathologic changes. The puncture in the experimental animals was performed under general anesthesia. In human patients testicular biopsy could be done under local anesthesia in an outpatient clinic. The procedure would be less painful, minimally invasive, and more cost-effective.

  15. CT-directed robotic biopsy testbed: motivation and concept

    NASA Astrophysics Data System (ADS)

    Cleary, Kevin R.; Stoianovici, Dan S.; Glossop, Neil D.; Gary, Kevin A.; Onda, Sumiyo; Cody, Richard; Lindisch, David; Stanimir, Alexandru; Mazilu, Dumitru; Patriciu, Alexandru; Watson, Vance; Levy, Elliot

    2001-05-01

    As a demonstration platform, we are developing a robotic biopsy testbed incorporating a mobile CT scanner, a small needle driver robot, and an optical localizer. This testbed will be used to compare robotically assisted biopsy to the current manual technique, and allow us to investigate software architectures for integrating multiple medical devices. This is a collaboration between engineers and physicians from three universities and a commercial vendor. In this paper we describe the CT-directed biopsy technique, review some other biopsy systems including passive and semi- autonomous devices, describe our testbed components, and present our software architecture. This testbed is a first step in developing the image-guided, robotically assisted, physician directed, biopsy systems of the future.

  16. Patient information preferences and behaviour in relation to oral biopsies.

    PubMed

    López-Jornet, P; Camacho-Alonso, F; Sanchez-Siles, M

    2012-12-01

    Our aim was to study the impact of information on the behaviour of patients who were to have an oral biopsy specimen taken. Patients were randomly assigned either to be given the basic information about oral biopsy or a more extensive amount of information. The Krantz Health Opinion Survey was used as a measure of preferences in decisions made about oral biopsy, and we used a questionnaire to assess anxiety. A total of 260 patients were studied. The participants were satisfied with the information provided (both form and content), but significantly more of those given basic information would have liked to know more (p=0.02). We conclude that information exerts a clear effect on patients' attitude to oral biopsy. Provision of preoperative information leads to significantly less anxiety in all patients having a procedure under local anaesthesia. The results emphasise that patients need to be adequately informed about oral biopsy.

  17. The global burden of major infectious complications following prostate biopsy.

    PubMed

    Bennett, H Y; Roberts, M J; Doi, S A R; Gardiner, R A

    2016-06-01

    We present a systematic review providing estimates of the overall and regional burden of infectious complications following prostate biopsy. A directly standardized prevalence estimate was used because it reflects the burden of disease more explicitly. Complications included sepsis, hospitalization, bacteraemia, bacteriuria, and acute urinary retention after biopsy. There were 165 articles, comprising 162 577 patients, included in the final analysis. Our findings demonstrate that transrectal biopsy was associated with a higher burden of hospitalization (1·1% vs. 0·9%) and sepsis (0·8% vs. 0·1%) compared to transperineal biopsy, while acute urinary retention was more prevalent after transperineal than transrectal biopsy (4·2% vs. 0·9%). The differences were statistically non-significant because of large heterogeneity across countries. We also demonstrate and discuss regional variations in complication rates, with Asian studies reporting higher rates of sepsis and hospitalization. PMID:26645476

  18. Microfabricated instrument for tissue biopsy and analysis

    SciTech Connect

    Krulevitch, P.A.; Lee, A.P.; Northrup, M.A.; Benett, W.J.

    1999-11-16

    This invention relates to a microfabricated biopsy/histology instrument which has several advantages over the conventional procedures. The advantages include: minimal specimen handling; smooth cutting edges with atomic sharpness capable of slicing very thin specimens (approximately 2 {mu}m or greater); micro-liter volumes of chemicals for treating the specimens; low cost; disposable; fabrication process which renders sterile parts; and ease of use. The cutter is a cheese-grater style design comprising a block or substrate of silicon and which uses anisotropic etching of the silicon to form extremely sharp and precise cutting edges. As a specimen is cut, it passes through the silicon cutter and lies flat on a piece of glass which is bonded to the cutter. Microchannels are etched into the glass or silicon substrates for delivering small volumes of chemicals for treating the specimen. After treatment, the specimens can be examined through the glass substrate. For automation purposes, microvalves and micropumps may be incorporated. Also, specimens in parallel may be cut and treated with identical or varied chemicals. The instrument is disposable due to its low cost and thus could replace current expensive microtome and histology equipment.

  19. Uncompacted myelin lamellae in peripheral nerve biopsy.

    PubMed

    Vital, Claude; Vital, Anne; Bouillot, Sandrine; Favereaux, Alexandre; Lagueny, Alain; Ferrer, Xavier; Brechenmacher, Christiane; Petry, Klaus G

    2003-01-01

    Since 1979, the authors have studied 49 peripheral nerve biopsies presenting uncompacted myelin lamellae (UML). Based on the ultrastructural pattern of UML they propose a 3-category classification. The first category includes cases displaying regular UML, which was observed in 43 cases; it was more frequent in 9 cases with polyneuropathy organomegaly endocrinopathy m-protein skin changes (POEMS) syndrome as well as in 1 case of Charcot-Marie-Tooth 1B with a novel point mutation in the P0 gene. The second category consists of cases showing irregular UML, observed in 4 cases with IgM monoclonal gammopathy and anti-myelin-associated glycoprotein (MAG) activity. This group included 1 benign case and 3 B-cell malignant lymphomas. The third category is complex UML, which was present in 2 unrelated patients with an Arg 98 His missense mutation in the P0 protein gene. Irregular and complex UML are respectively related to MAG and P0, which play a crucial role in myelin lamellae compaction and adhesion.

  20. Fine needle aspiration biopsy of thyroid nodules

    PubMed Central

    Arda, I; Yildirim, S; Demirhan, B; Firat, S

    2001-01-01

    BACKGROUND—Fine needle aspiration biopsy (FNA) is a routine diagnostic technique for evaluating thyroid nodules. Many reports in adults consider that FNA is superior to thyroid ultrasonography (USG) and radionuclide scanning (RS). Only five studies have been published on FNA of childhood thyroid nodules.
AIMS—To investigate the reliability of FNA in the evaluation and management of thyroid nodules, and compare the results of FNA, USG, and RS with regard to final histopathological diagnosis.
METHODS—FNA was performed in 46 children with thyroid nodules after USG and RS examination. We investigated the sensitivity, specificity, accuracy, and positive and negative predictive values of USG, RS, and FNA in their management.
RESULTS—Six patients who had malignant or suspicious cells on FNA examination underwent immediate surgery. The other 40 patients received medical treatment according to their hormonal status. Fifteen of these nodules either disappeared or decreased in number and/or size. Surgery was performed in 25 patients who did not respond to therapy. Statistical analysis revealed sensitivity, specificity, accuracy, and positive and negative predictive values respectively as follows: 60%, 59%, 59%, 15%, and 92% for USG; 30%, 42%, 39%, 12%, and 68% for SC; 100%, 95%, 95%, 67%, and 100% for FNAB.
CONCLUSION—FNAB is as reliable in children as in adults for definitive diagnosis of thyroid nodules. Using this technique avoids unnecessary thyroid surgery in children.

 PMID:11567941

  1. Microfabricated instrument for tissue biopsy and analysis

    DOEpatents

    Krulevitch, Peter A.; Lee, Abraham P.; Northrup, M. Allen; Benett, William J.

    1999-01-01

    A microfabricated biopsy/histology instrument which has several advantages over the conventional procedures, including minimal specimen handling, smooth cutting edges with atomic sharpness capable of slicing very thin specimens (approximately 2 .mu.m or greater), micro-liter volumes of chemicals for treating the specimens, low cost, disposable, fabrication process which renders sterile parts, and ease of use. The cutter is a "cheese-grater" style design comprising a block or substrate of silicon and which uses anisotropic etching of the silicon to form extremely sharp and precise cutting edges. As a specimen is cut, it passes through the silicon cutter and lies flat on a piece of glass which is bonded to the cutter. Microchannels are etched into the glass or silicon substrates for delivering small volumes of chemicals for treating the specimen. After treatment, the specimens can be examined through the glass substrate. For automation purposes, microvalves and micropumps may be incorporated. Also, specimens in parallel may be cut and treated with identical or varied chemicals. The instrument is disposable due to its low cost and thus could replace current expensive microtome and histology equipment.

  2. The role of biopsy in incidental renal tumours☆

    PubMed Central

    Al-Marhoon, Mohammed S.

    2011-01-01

    Purpose Historically, the biopsy of renal masses was not advocated, and to date there remains some controversy on the role of biopsy for renal masses in making treatment decisions. With the widespread use of imaging methods, the incidental diagnosis of renal masses has increased, necessitating renal biopsies to better plan the management of these tumours. Here I review previous reports to define the role of biopsy in incidental renal tumours. Methods Data were obtained from English-language studies listed in PubMed on the use of renal biopsy for evaluating incidental solid small renal tumours. Results The biopsy of small renal tumours is increasingly accepted due to: the increase in the incidence of small renal tumours; the finding that a significant number of these tumours are benign; the availability of new management options, such as ablative therapy and surveillance strategies; that imaging alone is unable to predict the biological behaviour of these tumours; and advances in the pathological evaluation of the biopsies. The biopsy procedure has an acceptable complication rate but is not free of limitations. The current recommendations for the use of renal biopsy in small renal tumours are: to help in differentiating benign from malignant renal tumours; before or during ablative therapies and during the follow-up after ablative therapies, for defining treatment success or failure; and to exclude nonrenal cell primary tumours (metastasis and lymphoma) or benign conditions (abscess), which may not require surgery. Conclusions The biopsy of small renal tumours is a safe and accurate procedure, and can help in the planning of definitive patient management. PMID:26579260

  3. [The repeated biopsy in patients with lupus nephritis].

    PubMed

    Subils, Gisella; Alba, Paula; Gobbi, Carla; Astesana, Pablo; Babini, Alejandra; Albiero, Eduardo

    2014-01-01

    We retrospectively studied patients with SLE according to ACR criteria, with NL who underwent a repeat renal biopsy from 2005 to 2012. We analyzed the main indications of renal biopsies, the histopathological Class and activity and chronicity changes. RESULTS The total number of patients with NL was 120, of which 18 (15%) patients underwent repeat renal biopsy, 18 had 2 renal biopsies and 6 had 3 biopsies. 3 (16.7%) patients were smokers; 1 (5.6%) had a history of previous DBT, 2 (11.1%) had a history of hypertension; and 3 (16.7%) patients had previous obesity. The duration of SLE was 15 ± 96 months; the time between the 1st and the 2nd biopsy was 45 ± 11 months and the time between the 2nd and 3rd biopsy was 56 ± 12 months. Indications for repeat biopsy were proteinuria in 10 biopsies (41.6%); proteinuria with impaired renal function in 2 biopsies (8.3%); proteinuria with pathological urine sediment in 8 (33.3%); . and pathological proteinuria with pathological urine sediment and impaired renal function in 4 biopsies (16.6%) The most frequent histological changes found between first and repeat biopsies were class IV to class III: 2 (8.2%) ; Class IV to Class IV: 8 (33.3%), class IV to class III + V: 2 (8.2%); class IV to class IV + V 3 (12.5%); class IV to class V: 2 (8.2%). Changes in NL biopsies with proliferative activity and chronicity indices (A / C) were: A to A / C: 7 (29.1%), A / C to A / C: 7 (29.1%). The immunosuppressive therapy was increased in 79.1% and 16.6% remained without changes. 20% patients received cyclophosphamide 1 g every 30 days, 26% Cyclophosphamide 500 mg every 15 days, 23% induction therapy with mycophenolate mofetil; 23% with Rituximab; 8% Cyclosporin A. Maintenance therapy with mycophenolate mofetil was performed in 87.5%; azathioprine in 1 case. Hydroxychloroquine was used in all cases.

  4. Microbiological diagnosis of vertebral osteomyelitis: relevance of second percutaneous biopsy following initial negative biopsy and limited yield of post-biopsy blood cultures.

    PubMed

    Gras, G; Buzele, R; Parienti, J J; Debiais, F; Dinh, A; Dupon, M; Roblot, F; Mulleman, D; Marcelli, C; Michon, J; Bernard, L

    2014-03-01

    The purpose of this investigation was to evaluate the microbiological diagnosis yield of post-biopsy blood cultures (PBBCs) and second percutaneous needle biopsy (PNB) following an initial negative biopsy in vertebral osteomyelitis (VO) without bacteremia. A retrospective multicenter study was performed. Patients with VO, pre-biopsy negative blood culture(s), ≥1 PNB, and ≥1 PBBC (0-4 h) were included. One hundred and sixty-nine PNBs (136 first and 33 following initial negative biopsy) were performed for 136 patients (median age = 58 years, sex ratio M/F = 1.9). First and second PNBs had a similar yield: 43.4 % (59/136) versus 39.4 % (13/33), respectively. Only two PBBCs (1.1 %) led to a microbiological diagnosis. The strategy with positive first PNB and second PNB following an initial negative result led to microbiological diagnosis in 79.6 % (74/93) of cases versus 44.1 % (60/136) for the strategy with only one biopsy. In the multivariate analysis, young age (odds ratio, OR [95 % confidence interval (CI)] = 0.98 [0.97; 0.99] per 1 year increase, p = 0.02) and >1 sample (OR = 2.4 ([1.3; 4.4], p = 0.007)) were independently associated with positive PNB. To optimize microbiological diagnosis in vertebral osteomyelitis, performing a second PNB (after an initial negative biopsy) could lead to a microbiological diagnosis in nearly 80 % of patients. PBBC appears to be limited in microbiological diagnosis.

  5. Renal biopsy practice: What is the gold standard?

    PubMed

    Brachemi, Soumeya; Bollée, Guillaume

    2014-11-01

    Renal biopsy (RB) is useful for diagnosis and therapy guidance of renal diseases but incurs a risk of bleeding complications of variable severity, from transitory haematuria or asymptomatic hematoma to life-threatening hemorrhage. Several risk factors for complications after RB have been identified, including high blood pressure, age, decreased renal function, obesity, anemia, low platelet count and hemostasis disorders. These should be carefully assessed and, whenever possible, corrected before the procedure. The incidence of serious complications has become low with the use of automated biopsy devices and ultrasound guidance, which is currently the "gold standard" procedure for percutaneous RB. An outpatient biopsy may be considered in a carefully selected population with no risk factor for bleeding. However, controversies persist on the duration of observation after biopsy, especially for native kidney biopsy. Transjugular RB and laparoscopic RB represent reliable alternatives to conventional percutaneous biopsy in patients at high risk of bleeding, although some factors limit their use. This aim of this review is to summarize the issues of complications after RB, assessment of hemorrhagic risk factors, optimal biopsy procedure and strategies aimed to minimize the risk of bleeding.

  6. Brain biopsy in neurologic decline of unknown etiology.

    PubMed

    Magaki, Shino; Gardner, Tracie; Khanlou, Negar; Yong, William H; Salamon, Noriko; Vinters, Harry V

    2015-04-01

    Brain biopsies have an uncertain role in the diagnosis of patients with dementia or neurologic decline of unknown etiology. They are often performed only after an exhaustive panel of less invasive tests and procedures have failed to provide a definitive diagnosis. The objective of this study was to evaluate the sensitivity of brain biopsies in this patient group through the retrospective analysis of 53 brain biopsies performed for neurologic disease of unknown etiology at a single tertiary care institution between December 2001 and December 2011. Patients with known nonlymphomatous neoplasms thought to be associated with the neurologic symptoms or with immunodeficiency were excluded from the study. Furthermore, the clinical presentation, imaging and laboratory tests were compared between diagnostic groups to identify factors more likely to yield a diagnosis. Sixty percent of the biopsies were diagnostic (32 of 53), with the most common histologic diagnosis of central nervous system lymphoma in 14 of 53 patients (26% of total) followed by infarct in four subjects (7.5%). A few patients were found to have rare and unsuspected diseases such as lymphomatosis cerebri, neurosarcoidosis and neuroaxonal leukodystrophy. Complications from biopsy were uncommon and included hemorrhage and infection with abscess formation at the biopsy site. These results suggest that brain biopsies may be useful in difficult cases in which less invasive measures have been unable to yield a definitive diagnosis.

  7. Strategies for prevention of ultrasound-guided prostate biopsy infections

    PubMed Central

    Lu, Diane D; Raman, Jay D

    2016-01-01

    Prostate cancer is the most common cancer in male patients and the second leading cause of cancer-related mortality in males. To confirm the diagnosis of prostate cancer, an ultrasound-guided needle biopsy is necessary to obtain prostate tissue sufficient for histologic analysis by pathologists. Ultrasound-guided prostate needle biopsy can be accomplished via a transperineal or transrectal approach. The latter biopsy technique involves placing an ultrasound probe into the rectum, visualizing the prostate located just anterior to it, and then obtaining 12–14 biopsies. Each biopsy core requires piercing of the rectal mucosa which can inherently contribute to infection. The increasing infectious risk of prostate needle biopsy requires refinement and re-evaluation of the process in which the technique is performed. Such processes include (but are not limited to) prebiopsy risk stratification, antibiotic prophylaxis, use of rectal preparations, and equipment processing. In the subsequent review, we highlight the current available information on different strategies to reduce the risk of infection following prostate needle biopsy. PMID:27468242

  8. High-frequency ultrasound imaging for breast cancer biopsy guidance.

    PubMed

    Cummins, Thomas; Yoon, Changhan; Choi, Hojong; Eliahoo, Payam; Kim, Hyung Ham; Yamashita, Mary W; Hovanessian-Larsen, Linda J; Lang, Julie E; Sener, Stephen F; Vallone, John; Martin, Sue E; Kirk Shung, K

    2015-10-01

    Image-guided core needle biopsy is the current gold standard for breast cancer diagnosis. Microcalcifications, an important radiographic finding on mammography suggestive of early breast cancer such as ductal carcinoma in situ, are usually biopsied under stereotactic guidance. This procedure, however, is uncomfortable for patients and requires the use of ionizing radiation. It would be preferable to biopsy microcalcifications under ultrasound guidance since it is a faster procedure, more comfortable for the patient, and requires no radiation. However, microcalcifications cannot reliably be detected with the current standard ultrasound imaging systems. This study is motivated by the clinical need for real-time high-resolution ultrasound imaging of microcalcifications, so that biopsies can be accurately performed under ultrasound guidance. We have investigated how high-frequency ultrasound imaging can enable visualization of microstructures in ex vivo breast tissue biopsy samples. We generated B-mode images of breast tissue and applied the Nakagami filtering technique to help refine image output so that microcalcifications could be better assessed during ultrasound-guided core biopsies. We describe the preliminary clinical results of high-frequency ultrasound imaging of ex vivo breast biopsy tissue with microcalcifications and without Nakagami filtering and the correlation of these images with the pathology examination by hematoxylin and eosin stain and whole slide digital scanning. PMID:26693167

  9. Sentinel Lymph Node Biopsy in Colon Cancer

    PubMed Central

    Bembenek, Andreas E.; Rosenberg, Robert; Wagler, Elke; Gretschel, Stephan; Sendler, Andreas; Siewert, Joerg-Ruediger; Nährig, Jörg; Witzigmann, Helmut; Hauss, Johann; Knorr, Christian; Dimmler, Arno; Gröne, Jörn; Buhr, Heinz-Johannes; Haier, Jörg; Herbst, Hermann; Tepel, Juergen; Siphos, Bence; Kleespies, Axel; Koenigsrainer, Alfred; Stoecklein, Nikolas H.; Horstmann, Olaf; Grützmann, Robert; Imdahl, Andreas; Svoboda, Daniel; Wittekind, Christian; Schneider, Wolfgang; Wernecke, Klaus-Dieter; Schlag, Peter M.

    2007-01-01

    Introduction: The clinical impact of sentinel lymph node biopsy (SLNB) in colon cancer is still controversial. The purpose of this prospective multicenter trial was to evaluate its clinical value to predict the nodal status and identify factors that influence these results. Methods: Colon cancer patients without prior colorectal surgery or irradiation were eligible. The sentinel lymph node (SLN) was identified intraoperatively by subserosal blue dye injection around the tumor. The SLN underwent step sections and immunohistochemistry (IHC), if classified free of metastases after routine hematoxylin and eosin examination. Results: At least one SLN (median, n = 2) was identified in 268 of 315 enrolled patients (detection rate, 85%). Center experience, lymphovascular invasion, body mass index (BMI), and learning curve were positively associated with the detection rate. The false-negative rate to identify pN+ patients by SLNB was 46% (38 of 82). BMI showed a significant association to the false-negative rate (P < 0.0001), the number of tumor-involved lymph nodes was inversely associated. If only slim patients (BMI ≤24) were investigated in experienced centers (>22 patients enrolled), the sensitivity increased to 88% (14 of 16). Moreover, 21% (30 of 141) of the patients, classified as pN0 by routine histopathology, revealed micrometastases or isolated tumor cells (MM/ITC) in the SLN. Conclusions: The contribution of SLNB to conventional nodal staging of colon cancer patients is still unspecified. Technical problems have to be resolved before a definite conclusion can be drawn in this regard. However, SLNB identifies about one fourth of stage II patients to reveal MM/ITC in lymph nodes. Further studies must clarify the clinical impact of these findings in terms of prognosis and the indication of adjuvant therapy. PMID:17522509

  10. Towards the mid-infrared optical biopsy

    NASA Astrophysics Data System (ADS)

    Seddon, Angela B.; Benson, Trevor M.; Sujecki, Slawomir; Abdel-Moneim, Nabil; Tang, Zhuoqi; Furniss, David; Sojka, Lukasz; Stone, Nick; Jayakrupakar, Nallala; Lloyd, Gavin R.; Lindsay, Ian; Ward, Jon; Farries, Mark; Moselund, Peter M.; Napier, Bruce; Lamrini, Samir; Møller, Uffe; Kubat, Irnis; Petersen, Christian R.; Bang, Ole

    2016-03-01

    We are establishing a new paradigm in mid-infrared molecular sensing, mapping and imaging to open up the midinfrared spectral region for in vivo (i.e. in person) medical diagnostics and surgery. Thus, we are working towards the mid-infrared optical biopsy (`opsy' look at, bio the biology) in situ in the body for real-time diagnosis. This new paradigm will be enabled through focused development of devices and systems which are robust, functionally designed, safe, compact and cost effective and are based on active and passive mid-infrared optical fibers. In particular, this will enable early diagnosis of external cancers, mid-infrared detection of cancer-margins during external surgery for precise removal of diseased tissue, in one go during the surgery, and mid-infrared endoscopy for early diagnosis of internal cancers and their precision removal. The mid-infrared spectral region has previously lacked portable, bright sources. We set a record in demonstrating extreme broad-band supercontinuum generated light 1.4 to 13.3 microns in a specially engineered, high numerical aperture mid-infrared optical fiber. The active mid-infrared fiber broadband supercontinuum for the first time offers the possibility of a bright mid-infrared wideband source in a portable package as a first step for medical fiber-based systems operating in the mid-infrared. Moreover, mid-infrared molecular mapping and imaging is potentially a disruptive technology to give improved monitoring of the environment, energy efficiency, security, agriculture and in manufacturing and chemical processing. This work is in part supported by the European Commission: Framework Seven (FP7) Large-Scale Integrated Project MINERVA: MId-to-NEaR- infrared spectroscopy for improVed medical diAgnostics (317803; www.minerva-project.eu).

  11. Does Prebiopsy, Nonsterile Ultrasonography Gel Affect Biopsy-Site Asepsis?

    SciTech Connect

    Gurel, Kamil Karabay, Oguz; Gurel, Safiye; Hildebolt, Charles

    2008-01-15

    Purpose. The purpose of this study was to determine the extent to which the use of nonsterile gel, prior to antiseptic procedures in ultrasonography (US)-guided percutaneous biopsies, results in contamination of the biopsy site. Materials and Methods. Patients referred for US-guided percutaneous biopsies were included in this study. Transmission material used for US evaluation before biopsy-site antiseptic procedures were performed was either nonsterile gel or sterile saline. Patients were randomly assigned to two groups: nonsterile gel (n = 30) and sterile saline (n = 30). Before the transmission material was used and after antiseptic procedures were performed, microbial swabs of a 10-cm{sup 2}-diameter area were obtained at the biopsy site. Swabs were also obtained from the gel, saline, and povidine-iodine. Inoculated specimen plates were incubated at 37{sup o}C under aerobic conditions, and the numbers of colony-forming units recorded. Nominal logistic regression analysis was used to calculate the odds of postantisepsis bacterial growth (after antiseptic procedures were performed) based on group, gender, coincidental disease (diabetes, chronic renal failure, and malignancy), biopsy-site location (head and neck or breast and abdomen), and local factors (skin fold, skin tag, and hair). Results. The following odds ratios (adjusted for the other variables) and their 95% confidence intervals were calculated: (1) group (2.9 [0.8-11.1]; p = 0.10); (2) gender (1.2 [0.3-5.2]; p = 0.78); (3) coincidental disease (7.6 [0.9-166.7]; p = 0.09); (4) biopsy site location (6.2 [1.4-31.3]; p = 0.02); and (5) local factors (7.0 [1.6-36.0]; p = 0.01). No bacterial growth occurred with swabs obtained from gel, povidine-iodine, or saline. Conclusion. We conclude that nonsterile gel used prior to percutaneous biopsy does not affect biopsy-site asepsis.

  12. Current indications for renal biopsy: a questionnaire-based survey.

    PubMed

    Fuiano, G; Mazza, G; Comi, N; Caglioti, A; De Nicola, L; Iodice, C; Andreucci, M; Andreucci, V E

    2000-03-01

    Indications for renal biopsy are still ill defined. We recently sent a detailed questionnaire to 360 nephrologists in different areas of the world with the aim of providing information on this critical issue by evaluating the replies. The questionnaire was organized in four sections that included questions on renal biopsy indications in patients with normal renal function, renal insufficiency, and a transplanted kidney. In addition, the questions included methods applied to each renal biopsy procedure and to specimen processing. We received 166 replies; North Europe (50 replies), South Europe (47 replies), North America (31 replies), Australia and New Zealand (24 replies), and other countries (14 replies). In patients with normal renal function, primary indications for renal biopsy were microhematuria associated with proteinuria, particularly greater than 1 g/d of protein. In chronic renal insufficiency, kidney dimension was the major parameter considered before renal biopsy, whereas the presence of diabetes or serological abnormalities was not considered critical. In the course of acute renal failure (ARF) of unknown origin, 20% of the respondents would perform renal biopsy in the early stages, 26% after 1 week of nonrecovery, and 40% after 4 weeks. In a transplanted kidney, the majority of nephrologists would perform a renal biopsy in the case of graft failure after surgery, ARF after initial good function, slow progressive deterioration of renal function, and onset of nephrotic proteinuria. The last section provided comprehensive information on the technical aspects of renal biopsy. This survey represents the first attempt to provide a reliable consensus that can be used in developing guidelines on the use of kidney biopsy. PMID:10692270

  13. Cutaneous metastatic pigmented breast carcinoma.

    PubMed

    Gaitan-Gaona, Francisco; Said, Mirra C; Valdes-Rodriguez, Rodrigo

    2016-01-01

    A 66-year-old woman presented with a 3 cm black, ulcerated nodule located on the skin of the upper abdomen, just below the breast. The lesion was painful to the touch, but the patient reported no other associated symptoms and was otherwise healthy. A 4-mm punch biopsy of the affected skin was obtained and the histological diagnosis was cutaneous metastatic pigmented breast carcinoma. PMID:27136637

  14. Comparison of a new aspiration needle device and the Quick-Core biopsy needle for transjugular liver biopsy

    PubMed Central

    Ishikawa, Toru; Kamimura, Hiroteru; Tsuchiya, Atsunori; Togashi, Tadayuki; Watanabe, Kouji; Seki, Kei-ichi; Ohta, Hironobu; Yoshida, Toshiaki; Ishihara, Noriko; Kamimura, Tomoteru

    2006-01-01

    AIM: To evaluate sample adequacy, safety, and needle passes of a new biopsy needle device compared to the Quick-Core biopsy needle for transjugular liver biopsy in patients affected by liver disease. METHODS: Thirty consecutive liver-disease patients who had major coagulation abnormalities and/or relevant ascites underwent transjugular liver biopsy using either a new needle device (18 patients) or the Quick-Core biopsy needle (12 patients). The length of the specimens was measured before fixation. A pathologist reviewed the histological slides for sample adequacy and pathologic diagnoses. The two methods’ specimen adequacy and complication rates were assessed. RESULTS: Liver biopsies were technically successful in all 30 (100%) patients, with diagnostic histological core specimens obtained in 30 of 30 (100%) patients, for an overall success rate of 100%. With the new device, 18 specimens were obtained, with an average of 1.1 passes per patient. Using the Quick-Core biopsy needle, 12 specimens were obtained, with an average of 1.8 passes per patient. Specimen length was significantly longer with the new needle device than with the Quick-Core biopsy needle (P < 0.05). The biopsy tissue was not fragmented in any of the specimens with the new aspiration needle device, but tissue was fragmented in 3 of 12 (25.0%) specimens obtained using the Quick-Core biopsy needle. Complications included cardiac arrhythmia in 3 (10.0%) patients, and transient abdominal pain in 4 (13.3%) patients. There were no cases of subcapsular hematoma, hemoperitoneum, or sepsis, and there was no death secondary to the procedure. In particular, no early or delayed major procedure-related complications were observed in any patient. CONCLUSION: Transjugular liver biopsy is a safe and effective procedure, and there was significant difference in the adequacy of the specimens obtained using the new needle device compared to the Quick-Core biopsy needle. Using the new biopsy needle device, the

  15. ALK positivity on pleuroscopic pleural biopsy in lung adenocarcinoma.

    PubMed

    Vaidya, Preyas J; Kate, Arvind H; Mehta, Deval; Dhabar, Boman N; Chhajed, Prashant N

    2016-01-01

    Lung cancer is the leading cause of cancer deaths worldwide, and around 75% to 80% of lung cancers are detected in advanced stage. Multiple genetic mutations are identified and reported in adenocarcinoma of the lung. Various pulmonary samples can be tested for molecular mutations in lung cancer. However, feasibility of molecular profiling of pleuroscopic pleural biopsies in lung adenocarcinoma is not reported. We describe a case of advanced adenocarcinoma of lung with positive anaplastic lymphoma tyrosine kinase mutation on pleuroscopic pleural biopsy and improved with oral crizotinib. The current case highlights the feasibility of pleuroscopy.-guided pleural biopsies in molecular profiling of lung adenocarcinoma. PMID:27461706

  16. The diagnosis of cancer in thyroid fine needle aspiration biopsy. Surgery, repeat biopsy or specimen consultation?

    PubMed

    Stanek-Widera, A; Biskup-Frużyńska, M; Zembala-Nożyńska, E; Śnietura, M; Lange, D

    2016-03-01

    Fine needle aspiration biopsy (FNA) is the only diagnostic method that allows a preoperative diagnosis of thyroid carcinoma. An unequivocal diagnosis of a malignant change is achievable only in cases in which all cytological criteria of carcinoma are met. The aim of the study was to evaluate the necessity of repeat thyroid FNA in patients with papillary thyroid carcinoma verified on consultative examination (CE). We analyzed cytology reports of thyroid FNA and CE that resulted in the diagnosis of papillary carcinoma. Evaluation of the correlation of the cytological diagnosis with the histopathology report was based on data obtained after the surgery. Between 2010 and 2015 in the Institute of Oncology (IO) there were 184 cancers diagnosed on CE or in thyroid FNA performed primarily in IO. Additionally, 74 patients were subjected to repeat biopsy after confirmation of cancer in CE. Histopathological diagnosis of cancer was obtained in 62 (100%) cases that were doubly confirmed with cytological examination. The remaining 12 patients were operated on outside the institute. From 110 FNA primarily performed in the IO, histopathological verification was achievable in 92 cases, from which 92 (100%) provided a confirmation of cancer, and the remaining 18 patients were operated on outside the institute. High (100%) specificity of cancer diagnosis in FNA established primarily and verified on CE (second independent assessment) indicates that repeat FNA in order to confirm the diagnosis is unnecessary. PMID:27179270

  17. Transfemoral liver biopsy using a Quick-Core biopsy needle system in living donor liver transplantation recipients.

    PubMed

    Li, Fen Qiang; Ko, Gi-Young; Sung, Kyu-Bo; Gwon, Dong-Il; Ko, Heung Kyu; Kim, Jong Woo; Yu, Eunsil

    2014-10-01

    The purpose of this study was to evaluate the efficacy and safety of transfemoral liver biopsy with a Quick-Core biopsy needle in select living donor liver transplantation (LDLT) recipients. Eight LDLT recipients underwent 9 transfemoral liver biopsy sessions. Six patients had undergone modified right lobe (mRL) LDLT, and 2 patients had undergone dual-left lobe LDLT. The indications for transfemoral liver biopsy were a hepatic vein (HV) at an acute angle to the inferior vena cava (IVC) on the coronal plane and a thin (<10-mm) liver parenchyma surrounding the HV to be biopsied on enhanced computed tomography. Under fluoroscopic guidance, the right inferior HV in the mRL or the left HV in the right-sided left lobe with a cranial orientation was negotiated with a 5-Fr catheter via the common femoral vein. Then, a stiffening cannula was introduced into the HV over a stiff guide wire. Needle passage was then performed with an 18- or 19-gauge Quick-Core biopsy needle. Technical success was achieved in all sessions without major complications. The median number of needle passages was 4 (range = 2-6). The median total length of obtained liver specimens in each session was 44 mm (range = 24-75 mm). The median number of portal tracts was 18 (range = 10-29), and the obtained liver specimens were adequate for histological diagnosis in all sessions. In conclusion, transfemoral liver biopsy with a Quick-Core biopsy needle is an effective and safe alternative for obtaining a liver specimen when standard transjugular liver biopsy is not feasible because of an unfavorable HV angle with respect to the IVC and/or a thin liver parenchyma surrounding the HV. PMID:24916429

  18. Ultra-High-Speed Observation of Cutting of Failure Phenomenon in Thin Metallic Lamina by Punch and Measurement of Displacements by Digital Image Correlation Method

    NASA Astrophysics Data System (ADS)

    Nishioka, Toshihisa; Iwawaki, Takashi; Fujimoto, Takehiro; Kashiwara, Yoshiyuki

    Machine components of industrial products are often produced by press cutting. However, the mechanism of cutting (ductile fracture of metals) is not perfectly understood. In order to clarify this mechanism, cutting processes were observed by an ultrahigh-speed camera. The ultrahigh-speed camera is capable of recording maximum record rate 1,000,000 frames per second (preserved images102 frames); each frame has 80,000 pixels. Therefore, this ultrahigh-speed camera is currently the world's most advanced camera in terms of spatial and time resolutions. A detailed movie of the cutting process was recorded. The details of the cutting process include the crack length versus time, crack tip opening angle, and fracture path. The crack tip opening angles were evaluated approximately 0.1 mm behind the tip of the propagating crack. The CTOA criterion was found to be almost valid during the cutting process. Furthermore, in order to use the image correlation method, random patterns were generated by spraying paint onto the metal sections. Images of a specimen section were taken after punching the sheet metal. The distributions of displacements were evaluated by the digital image correlation method. We found smoothly cut sections and rough surfaces. A smoothly cut section is very important for industrial products. In this study, the optimal speed of punching and punch-die clearances were examined. The ductile fracture criterion determined in this study is extremely useful for fabricating machine components by press cutting because it can be used for simulations without the need for a cutting system. The data of the image correlation method can be used for an intelligent hybrid method that can provide very accurate strain and stress distributions and fracture parameters such as the T* integral, which is the most promising fracture parameter for assessing the quality of metallic materials.

  19. Breast Biopsy: The Effects of Hypnosis and Music.

    PubMed

    Téllez, Arnoldo; Sánchez-Jáuregui, Teresa; Juárez-García, Dehisy M; García-Solís, Manuel

    2016-01-01

    The authors evaluated the efficacies of audio-recorded hypnosis with background music and music without hypnosis in the reduction of emotional and physical disturbances in patients scheduled for breast biopsy in comparison with a control group. A total of 75 patients were randomly assigned to 3 different groups and evaluated at baseline and before and after breast biopsy using visual analog scales of stress, pain, depression, anxiety, fatigue, optimism, and general well-being. The results showed that, before breast biopsy, the music group presented less stress and anxiety, whereas the hypnosis with music group presented reduced stress, anxiety, and depression and increased optimism and general well-being. After the biopsy, the music group presented less anxiety and pain, whereas the hypnosis group showed less anxiety and increased optimism. PMID:27585728

  20. [Stereotaxic brain biopsy in AIDS patients with neurological manifestations].

    PubMed

    Nasser, J A; Confort, C I; Ferraz, A; Esperança, J C; Duarte, F

    1998-06-01

    Prospective series showing the importance of computerized stereotactic brain biopsy in the management of AIDS patients neurologically symptomatic and confirmed by images. Patients undergone an algorithm step by step done by their own doctors and referred to us for stereotactic biopsy. Our protocol was opened in August 1995 and closed in December 1996. Twenty patients were biopsied. This protocol is similar to the Levy's one (Chicago IL, USA). We have got diagnosis in all cases. Lymphoma was predominant and followed by toxoplasmosis, progressive multifocal leukoencephalopathy and HIV encephalopathy. We included one patient with diploic giant cells lymphoma. Our mortality and morbidity was zero. By these results we conclude that stereotactic biopsy in AIDS patients is safe and effective.

  1. Drill biopsy in the diagnosis of lung lesions.

    PubMed

    Shatapathy, P; Sahoo, R C; Rao, K M; Krishnan, K V; Rau, P V; Padhee, A

    1987-11-01

    A high speed pneumatic drill was used to perform 190 percutaneous transthoracic biopsies in 161 patients. The resultant cores of tissue provided a definite diagnosis in 146 patients, giving a success rate of 90.7%. Complications occurred in 58 patients, subcutaneous emphysema being the most common, though only seven patients required active treatment, giving a rate of 3.7% for important complications. One patient died within 24 hours of the biopsy procedure owing to asphyxia resulting from aspiration of the contents of an acutely dilated stomach. Our experience clearly establishes that the drill biopsy as used by us is simple and safe and can be carried out in an outpatient department, yielding better overall results than any other procedure for closed biopsy of the lung currently practised.

  2. Magnetic Resonance Imaging-Guided Prostate Biopsy: Present and Future

    PubMed Central

    2015-01-01

    Systemic transrectal ultrasound-guided biopsy (TRUSBx) is the standard procedure for diagnosing prostate cancer (PCa), but reveals a limited accuracy for the detection of cancer. Currently, multiparametric MR imaging (mp-MRI) is increasingly regarded as a promising method to detect PCa with an excellent positive predictive value. The use of mp-MRI during a MRI-guided biopsy (MRGB) procedure improves the quality of a targeted biopsy. The aim of this article is to provide an overview about the MRGB technique for PCa detection, to review the accuracy and clinical indications of MRGB and discuss its current issues and further directions. A MRGB seems accurate and efficient for the detection of clinically significant PCa in men with previous negative TRUSBx. Moreover, it may decrease the detection of clinically insignificant cancers with fewer biopsy cores. PMID:25598677

  3. [Stereotaxic brain biopsy in AIDS patients with neurological manifestations].

    PubMed

    Nasser, J A; Confort, C I; Ferraz, A; Esperança, J C; Duarte, F

    1998-06-01

    Prospective series showing the importance of computerized stereotactic brain biopsy in the management of AIDS patients neurologically symptomatic and confirmed by images. Patients undergone an algorithm step by step done by their own doctors and referred to us for stereotactic biopsy. Our protocol was opened in August 1995 and closed in December 1996. Twenty patients were biopsied. This protocol is similar to the Levy's one (Chicago IL, USA). We have got diagnosis in all cases. Lymphoma was predominant and followed by toxoplasmosis, progressive multifocal leukoencephalopathy and HIV encephalopathy. We included one patient with diploic giant cells lymphoma. Our mortality and morbidity was zero. By these results we conclude that stereotactic biopsy in AIDS patients is safe and effective. PMID:9698730

  4. The disappearing clip: an unusual complication in MRI biopsy

    PubMed Central

    Bourke, Anita Geraldine; Peter, Prasant; Jose, Chaitra Lesli

    2014-01-01

    MRI-guided biopsies are being increasingly used for otherwise occult breast lesions. Clip migration has been reported however, to the best of our knowledge, there have been no documented cases of entire disappearance of a marker clip. Absence of the postbiopsy marker clip was noted when our patient returned for preoperative hook-wire localisation even though accurate clip placement had been confirmed on the post-MRI biopsy mammogram. PMID:25139917

  5. Pericardial Tamponade Following CT-Guided Lung Biopsy

    SciTech Connect

    Mitchell, Michael J.; Montgomery, Mark; Reiter, Charles G.; Culp, William C.

    2008-07-15

    While not free from hazards, CT-guided biopsy of the lung is a safe procedure, with few major complications. Despite its safety record, however, potentially fatal complications do rarely occur. We report a case of pericardial tamponade following CT-guided lung biopsy. Rapid diagnosis and therapy allowed for complete patient recovery. Physicians who perform this procedure should be aware of the known complications and be prepared to treat them appropriately.

  6. Low coherence interferometry approach for aiding fine needle aspiration biopsies

    NASA Astrophysics Data System (ADS)

    Chang, Ernest W.; Gardecki, Joseph; Pitman, Martha; Wilsterman, Eric J.; Patel, Ankit; Tearney, Guillermo J.; Iftimia, Nicusor

    2014-11-01

    We present portable preclinical low-coherence interference (LCI) instrumentation for aiding fine needle aspiration biopsies featuring the second-generation LCI-based biopsy probe and an improved scoring algorithm for tissue differentiation. Our instrument and algorithm were tested on 38 mice with cultured tumor mass and we show the specificity, sensitivity, and positive predictive value of tumor detection of over 0.89, 0.88, and 0.96, respectively.

  7. Advanced Imaging for Biopsy Guidance in Primary Brain Tumors

    PubMed Central

    Tsiouris, Apostolos J; Ramakrishna, Rohan

    2016-01-01

    Accurate glioma sampling is required for diagnosis and establishing eligibility for relevant clinical trials. MR-based perfusion and spectroscopy sequences supplement conventional MR in noninvasively predicting the areas of highest tumor grade for biopsy. We report the case of a patient with gliomatosis cerebri and multifocal patchy enhancement in whom the combination of advanced and conventional imaging attributes successfully guided a diagnostic biopsy. PMID:27014538

  8. Emergency right hepatectomy after laparoscopic tru-cut liver biopsy

    PubMed Central

    Quezada, Nicolás; León, Felipe; Martínez, Jorge; Jarufe, Nicolás; Guerra, Juan Francisco

    2015-01-01

    Background Liver biopsy is a common procedure usually required for final pathologic diagnosis of different liver diseases. Morbidity following tru-cut biopsy is uncommon, with bleeding complications generally self-limited. Few cases of major hemorrhage after liver biopsies have been reported, but to our knowledge, no cases of emergency hepatectomy following a tru-cut liver biopsy have been reported previously. Presentation of case We report the case of a 38 years-old woman who presented with an intrahepatic arterial bleeding after a tru-cut liver biopsy under direct laparoscopic visualization, initially controlled by ligation of the right hepatic artery and temporary liver packing. On tenth postoperative day, she developed a pseudo-aneurysm of the anterior branch of the right hepatic artery, evolving with massive bleeding that was not amenable to control by endovascular therapy. Therefore, an emergency right hepatectomy had to be performed in order to stop the bleeding. The patient achieved hemodynamic stabilization, but developed a biliary fistula from the liver surface, refractory to non-operative treatment. In consequence, a Roux-Y hepatico-jejunostomy was performed at third month, with no further complications. Discussion Bleeding following tru-cut biopsy is a rare event. To our knowledge, this is the first report of an emergency hepatectomy due to hemorrhage following liver biopsy. Risks and complications of liver biopsy are revised. Conclusion Care must be taken when performing this kind of procedures and a high level of suspicion regarding this complication should be taken in count when clinical/hemodynamic deterioration occurs after these procedures. PMID:25618399

  9. Low coherence interferometry approach for aiding fine needle aspiration biopsies

    PubMed Central

    Chang, Ernest W.; Gardecki, Joseph; Pitman, Martha; Wilsterman, Eric J.; Patel, Ankit; Tearney, Guillermo J.; Iftimia, Nicusor

    2014-01-01

    Abstract. We present portable preclinical low-coherence interference (LCI) instrumentation for aiding fine needle aspiration biopsies featuring the second-generation LCI-based biopsy probe and an improved scoring algorithm for tissue differentiation. Our instrument and algorithm were tested on 38 mice with cultured tumor mass and we show the specificity, sensitivity, and positive predictive value of tumor detection of over 0.89, 0.88, and 0.96, respectively. PMID:25375634

  10. Evaluation of electronic biopsy for clinical diagnosis in virtual colonoscopy

    NASA Astrophysics Data System (ADS)

    Marino, Joseph; Du, Wei; Barish, Matthew; Li, Ellen; Zhu, Wei; Kaufman, Arie

    2011-03-01

    Virtual colonoscopy provides techniques not available in optical colonoscopy, an exciting one being the ability to perform an electronic biopsy. An electronic biopsy image is created using ray-casting volume rendering of the CT data with a translucent transfer function mapping higher densities to red and lower densities to blue. The resulting image allows the physician to gain insight into the internal structure of polyps. Benign tissue and adenomas can be differentiated; the former will appear as homogeneously blue and the latter as irregular red structures. Although this technique is now common, is included with clinical systems, and has been used successfully for computer aided detection, there has so far been no study to evaluate the effectiveness of a physician using electronic biopsy in determining the pathological state of a polyp. We present here such a study, wherein an experienced radiologist ranked polyps based on electronic biopsy alone per scan (supine and prone), as well as both combined. Our results show a correct identification 77% of the time using prone or supine images alone, and 80% accuracy using both. Using ROC analysis based on this study with one reader and a modest sample size, the combined score is not significantly higher than using a single electronic biopsy image alone. However, our analysis indicates a trend of superiority for the combined ranking that deserves a follow-up confirmatory study with a larger sample and more readers. This study yields hope that an improved electronic biopsy technique could become a primary clinical diagnosis method.

  11. CT Fluoroscopy-Guided Lung Biopsy with Novel Steerable Biopsy Canula: Ex-Vivo Evaluation in Ventilated Porcine Lung Explants

    SciTech Connect

    Schaefer, Philipp J. Fabel, Michael; Bolte, Hendrik; Schaefer, Fritz K. W.; Jahnke, Thomas; Heller, Martin; Lammer, Johannes; Biederer, Juergen

    2010-08-15

    The purpose was to evaluate ex-vivo a prototype of a novel biopsy canula under CT fluoroscopy-guidance in ventilated porcine lung explants in respiratory motion simulations. Using an established chest phantom for porcine lung explants, n = 24 artificial lesions consisting of a fat-wax-Lipiodol mixture (approx. 70HU) were placed adjacent to sensible structures such as aorta, pericardium, diaphragm, bronchus and pulmonary artery. A piston pump connected to a reservoir beneath a flexible silicone reconstruction of a diaphragm simulated respiratory motion by rhythmic inflation and deflation of 1.5 L water. As biopsy device an 18-gauge prototype biopsy canula with a lancet-like, helically bended cutting edge was used. The artificial lesions were punctured under CT fluoroscopy-guidance (SOMATOM Sensation 64, Siemens, Erlangen, Germany; 30mAs/120 kV/5 mm slice thickness) implementing a dedicated protocol for CT fluoroscopy-guided lung biopsy. The mean-diameter of the artificial lesions was 8.3 {+-} 2.6 mm, and the mean-distance of the phantom wall to the lesions was 54.1 {+-} 13.5 mm. The mean-displacement of the lesions by respiratory motion was 14.1 {+-} 4.0 mm. The mean-duration of CT fluoroscopy was 9.6 {+-} 5.1 s. On a 4-point scale (1 = central; 2 = peripheral; 3 = marginal; 4 = off target), the mean-targeted precision was 1.9 {+-} 0.9. No misplacement of the biopsy canula affecting adjacent structures could be detected. The novel steerable biopsy canula proved to be efficient in the ex-vivo set-up. The chest phantom enabling respiratory motion and the steerable biopsy canula offer a feasible ex-vivo system for evaluating and training CT fluoroscopy-guided lung biopsy adapted to respiratory motion.

  12. Optimizing prostate needle biopsy through 3D simulation

    NASA Astrophysics Data System (ADS)

    Zeng, Jianchao; Kaplan, Charles; Xuan, Jian Hua; Sesterhenn, Isabell A.; Lynch, John H.; Freedman, Matthew T.; Mun, Seong K.

    1998-06-01

    Prostate needle biopsy is used for the detection of prostate cancer. The protocol of needle biopsy that is currently routinely used in the clinical environment is the systematic sextant technique, which defines six symmetric locations on the prostate surface for needle insertion. However, this protocol has been developed based on the long-term observation and experience of urologists. Little quantitative or scientific evidence supports the use of this biopsy technique. In this research, we aim at developing a statistically optimized new prostate needle biopsy protocol to improve the quality of diagnosis of prostate cancer. This new protocol will be developed by using a three-dimensional (3-D) computer- based probability map of prostate cancer. For this purpose, we have developed a computer-based 3-D visualization and simulation system with prostate models constructed from the digitized prostate specimens, in which the process of prostate needle biopsy can be simulated automatically by the computer. In this paper, we first develop an interactive biopsy simulation mode in the system, and evaluate the performance of the automatic biopsy simulation with the sextant biopsy protocol by comparing the results by the urologist using the interactive simulation mode with respect to 53 prostate models. This is required to confirm that the automatic simulation is accurate and reliable enough for the simulation with respect to a large number of prostate models. Then we compare the performance of the existing protocols using the automatic biopsy simulation system with respect to 107 prostate models, which will statistically identify if one protocol is better than another. Since the estimation of tumor volume is extremely important in determining the significance of a tumor and in deciding appropriate treatment methods, we further investigate correlation between the tumor volume and the positive core volume with 89 prostate models. This is done in order to develop a method to

  13. Wall or machine suction rectal biopsy for Hirschsprung's disease: a simple modified technique can improve the adequacy of biopsy.

    PubMed

    Ali, A E; Morecroft, J A; Bowen, J C; Bruce, J; Morabito, A

    2006-08-01

    Suction rectal biopsy (SRB) may not include sufficient submucosa for histological diagnosis of Hirschsprung's disease (HD) and a repeat biopsy is required. Substitution of the conventional syringe for sustained suction from a machine or wall suction unit could provide a more consistently adequate tissue biopsy. This study was conducted to compare the adequacy of SRB specimens using a conventional method of syringe suction (SSRB) with those taken by wall or machine suction (WSRB). Hospital records of patients who had a SRB between 2002 and 2004 were studied retrospectively. The biopsy was considered inadequate if there was insufficient submucosa and a repeat specimen was requested. SSRB were taken using the conventional SSRB technique. WSRB were taken with the same Noblett forceps but with suction from wall suction or from a portable suction machine. Ninety-five infants had 103 SRB, 24 had WSRB and all (100%) were adequate for histopathological diagnosis or exclusion of HD. Seventy nine conventional SSRB were undertaken in 71 infants of which 64 (81.02%) were adequate. The difference in adequacy between WSRB and SSRB was statistically significant (P = 0.02). There were no instances of haemorrhage or bowel perforation in either subgroup. WSRB with the Noblett biopsy forceps is more likely to produce an adequate specimen and to reduce the incidence of repeat biopsies.

  14. Percutaneous ultrasound-guided renal biopsy: A Libyan experience

    PubMed Central

    Mishra, A.; Tarsin, R.; ElHabbash, B.; Zagan, N.; Markus, R.; Drebeka, S.; AbdElmola, K.; Shawish, T.; Shebani, A.; AbdElmola, T.; ElUsta, A.; Ehtuish, E. F.

    2010-01-01

    This study was done to assess the safety and efficacy of ultrasound-guided percutaneous renal biopsy (PRB), to ascertain the risk factors for complications and determine the optimal period of observation. The radiologist (A.M.) at the National Organ Transplant Centre, Central Hospital, Tripoli, Libya, performed 86 PRBs between February 1, 2006, and January 31, 2008, using an automated biopsy gun with 16-gauge needle. Coagulation profile was done in all the patients. All patients were kept on strict bed rest for six hours post-procedure. Eighty six renal biopsies were performed on 78 patients referred from rheumatology department and eight post-kidney transplant recipients; 23 were males with age range 15 – 56 years and 63 females with age range 16 – 66 years. A mean of 17.5 glomeruli were present in each specimen. A glomerular yield of less than five glomeruli was seen in four biopsies. Class I lupus nephritis (LN) was seen in 1 patient, class II lupus nephritis in 7 patients, class III LN in 13 patients and class IV LN in 29 patients. All the eight renal allografts were diagnosed as acute tubular necrosis or acute interstitial rejection. The risk of post-biopsy bleeding was higher in women, older patients and higher PTT. The overall complication rate was 5.8%. Three complications were observed within six hours of biopsy. No late complication was seen. PRB under real-time ultrasound-guidance is a safe and efficacious procedure to establish the histological diagnosis and should be done as out-patient procedure. Observation time of six hours post-biopsy is optimal. PMID:20835320

  15. Polymerase chain reaction detection of Leishmania DNA in skin biopsy samples in Sri Lanka where the causative agent of cutaneous leishmaniasis is Leishmania donovani.

    PubMed

    Ranasinghe, Shalindra; Wickremasinghe, Renu; Hulangamuwa, Sanjeeva; Sirimanna, Ganga; Opathella, Nandimithra; Maingon, Rhaiza D C; Chandrasekharan, Vishvanath

    2015-12-01

    Leishmania donovani is the known causative agent of both cutaneous (CL) and visceral leishmaniasis in Sri Lanka. CL is considered to be under-reported partly due to relatively poor sensitivity and specificity of microscopic diagnosis. We compared robustness of three previously described polymerase chain reaction (PCR) based methods to detect Leishmania DNA in 38 punch biopsy samples from patients presented with suspected lesions in 2010. Both, Leishmania genus-specific JW11/JW12 KDNA and LITSR/L5.8S internal transcribed spacer (ITS)1 PCR assays detected 92% (35/38) of the samples whereas a KDNA assay specific forL. donovani (LdF/LdR) detected only 71% (27/38) of samples. All positive samples showed a L. donovani banding pattern upon HaeIII ITS1 PCR-restriction fragment length polymorphism analysis. PCR assay specificity was evaluated in samples containing Mycobacterium tuberculosis, Mycobacterium leprae, and human DNA, and there was no cross-amplification in JW11/JW12 and LITSR/L5.8S PCR assays. The LdF/LdR PCR assay did not amplify M. leprae or human DNA although 500 bp and 700 bp bands were observed in M. tuberculosis samples. In conclusion, it was successfully shown in this study that it is possible to diagnose Sri Lankan CL with high accuracy, to genus and species identification, using Leishmania DNA PCR assays.

  16. Endoscopic and biopsy diagnoses of superficial, nonampullary, duodenal adenocarcinomas

    PubMed Central

    Kakushima, Naomi; Kanemoto, Hideyuki; Sasaki, Keiko; Kawata, Noboru; Tanaka, Masaki; Takizawa, Kohei; Imai, Kenichiro; Hotta, Kinichi; Matsubayashi, Hiroyuki; Ono, Hiroyuki

    2015-01-01

    AIM: To investigate the accuracy of endoscopic or biopsy diagnoses of superficial nonampullary duodenal epithelial tumors (NADETs). METHODS: Clinicopathological data were reviewed for 84 superficial NADETs from 74 patients who underwent surgery or endoscopic resection between September 2002 and August 2014 at a single prefectural cancer center. Superficial NADETs were defined as lesions confined to the mucosa or submucosa. Demographic and clinicopathological data were retrieved from charts, endoscopic and pathologic reports. Endoscopic reports included endoscopic diagnosis, location, gross type, diameter, color, and presence or absence of biopsy. Endoscopic diagnoses were made by an endoscopist in charge of the examination before biopsy specimens were obtained. Endoscopic images were obtained using routine, front-view, high-resolution video endoscopy, and chromoendoscopy with indigocarmine was performed for all lesions. Endoscopic images were reviewed by at least two endoscopists to assess endoscopic findings indicative of carcinoma. Preoperative diagnoses based on endoscopy and biopsy findings were compared with histological diagnoses of resected specimens. Sensitivity, specificity, and accuracy were assessed for endoscopic diagnosis and biopsy diagnosis. RESULTS: The majority (81%) of the lesions were located in the second portion of the duodenum. The median lesion diameter was 14.5 mm according to final histology. Surgery was performed for 49 lesions from 39 patients, and 35 lesions from 35 patients were endoscopically resected. Final histology confirmed 65 carcinomas, 15 adenomas, and 3 hyperplasias. A final diagnosis of duodenal carcinoma was made for 91% (52/57) of the lesions diagnosed as carcinoma by endoscopy and 93% (42/45) of the lesions diagnosed as carcinoma by biopsy. The sensitivity, specificity, and accuracy of endoscopic diagnoses were 80%, 72%, and 78%, respectively, whereas those of biopsy diagnoses were 72%, 80%, and 74%, respectively

  17. Nose biopsy: a comparison between two sampling techniques.

    PubMed

    Segal, Nili; Osyntsov, Lidia; Olchowski, Judith; Kordeluk, Sofia; Plakht, Ygal

    2016-06-01

    Pre operative biopsy is important in obtaining preliminary information that may help in tailoring the optimal treatment. The aim of this study was to compare two sampling techniques of obtaining nasal biopsy-nasal forceps and nasal scissors in terms of pathological results. Biopsies of nasal lesions were taken from patients undergoing nasal surgery by two techniques- with nasal forceps and with nasal scissors. Each sample was examined by a senior pathologist that was blinded to the sampling method. A grading system was used to rate the crush artifact in every sample (none, mild, moderate, severe). A comparison was made between the severity of the crush artifact and the pathological results of the two techniques. One hundred and forty-four samples were taken from 46 patients. Thirty-one were males and the mean age was 49.6 years. Samples taken by forceps had significantly higher grades of crush artifacts compared to those taken by scissors. The degree of crush artifacts had a significant influence on the accuracy of the pre operative biopsy. Forceps cause significant amount of crush artifacts compared to scissors. The degree of crush artifact in the tissue sample influences the accuracy of the biopsy.

  18. Renal biopsy: Still a landmark for the nephrologist.

    PubMed

    Visconti, Luca; Cernaro, Valeria; Ricciardi, Carlo Alberto; Lacava, Viviana; Pellicanò, Vincenzo; Lacquaniti, Antonio; Buemi, Michele; Santoro, Domenico

    2016-07-01

    Renal biopsy was performed for the first time more than one century ago, but its clinical use was routinely introduced in the 1950s. It is still an essential tool for diagnosis and choice of treatment of several primary or secondary kidney diseases. Moreover, it may help to know the expected time of end stage renal disease. The indications are represented by nephritic and/or nephrotic syndrome and rapidly progressive acute renal failure of unknown origin. Nowadays, it is performed mainly by nephrologists and radiologists using a 14-18 gauges needle with automated spring-loaded biopsy device, under real-time ultrasound guidance. Bleeding is the major primary complication that in rare cases may lead to retroperitoneal haemorrhage and need for surgical intervention and/or death. For this reason, careful evaluation of risks and benefits must be taken into account, and all procedures to minimize the risk of complications must be observed. After biopsy, an observation time of 12-24 h is necessary, whilst a prolonged observation may be needed rarely. In some cases it could be safer to use different techniques to reduce the risk of complications, such as laparoscopic or transjugular renal biopsy in patients with coagulopathy or alternative approaches in obese patients. Despite progress in medicine over the years with the introduction of more advanced molecular biology techniques, renal biopsy is still an irreplaceable tool for nephrologists.

  19. Liquid Biopsy of Hepatocellular Carcinoma: Circulating Tumor-Derived Biomarkers.

    PubMed

    Yin, Chang-Qing; Yuan, Chun-Hui; Qu, Zhen; Guan, Qing; Chen, Hao; Wang, Fu-Bing

    2016-01-01

    Hepatocellular carcinoma (HCC) is the second leading cause of cancer-related death worldwide due to latent liver disease, late diagnosis, and nonresponse to systemic treatments. Till now, surgical and/or biopsy specimens are still generally used as a gold standard by the clinicians for clinical decision-making. However, apart from their invasive characteristics, tumor biopsy only mirrors a single spot of the tumor, failing to reflect current cancer dynamics and progression. Therefore, it is imperative to develop new diagnostic strategies with significant effectiveness and reliability to monitor high-risk populations and detect HCC at an early stage. In the past decade, the potent utilities of "liquid biopsy" have attracted intense concern and were developed to evaluate cancer progression in several clinical trials. "Liquid biopsies" represent a series of noninvasive tests that detect cancer byproducts easily accessible in peripheral blood, mainly including circulating tumor cells (CTCs) and cell-free nucleic acids (cfNAs) that are shed into the blood from the tumor sites. In this review, we focus on the recent developments in the field of "liquid biopsy" as well as the diagnostic and prognostic significance of CTCs and cfNAs in HCC patients. PMID:27403030

  20. Renal biopsy and pathologic evaluation of glomerular disease.

    PubMed

    Lees, George E; Cianciolo, Rachel E; Clubb, Fred J

    2011-08-01

    Presence of suspected primary glomerular disease is the most common and compelling reason to consider renal biopsy. Pathologic findings in samples from animals with nephritic or nephrotic glomerulopathies, as well as from animals with persistent subclinical glomerular proteinuria that is not associated with advanced chronic kidney disease, frequently guide treatment decisions and inform prognosis when suitable specimens are obtained and examined appropriately. Ultrasound-guided needle biopsy techniques generally are satisfactory; however, other methods of locating or approaching the kidney, such as manual palpation (e.g., in cats), laparoscopy, or open surgery, also can be used. Visual assessment of the tissue content of needle biopsy samples to verify that they are renal cortex (i.e., contain glomeruli) as they are obtained is a key step that minimizes the submission of uninformative samples for examination. Adequate planning for a renal biopsy also requires prior procurement of the fixatives and preservatives needed to process and submit samples that will be suitable for electron microscopic examination and immunostaining, as well as for light microscopic evaluation. Finally, to be optimally informative, renal biopsy specimens must be processed by laboratories that routinely perform the required specialized examinations and then be evaluated by experienced veterinary nephropathologists. The pathologic findings must be carefully integrated with one another and with information derived from the clinical investigation of the patient's illness to formulate the correct diagnosis and most informative guidance for therapeutic management of the animal's glomerular disease. PMID:21782145

  1. Surveillance biopsies after paediatric kidney transplantation: A review.

    PubMed

    Rose, Edward M; Kennedy, Sean E; Mackie, Fiona E

    2016-09-01

    Kidney transplantation is the most effective means of treating children with end-stage kidney disease, and yet, there continues to be a limited "life span" of transplanted kidneys in paediatric recipients. Early graft monitoring, using the surveillance biopsy, has the potential to extend renal allograft survival in paediatric recipients. The surveillance biopsy provides important and timely information about acute and chronic graft pathology, particularly SCR and calcineurin inhibitor-induced nephrotoxicity, which can subsequently guide management decisions and improve long-term graft survival. The ostensible value of the surveillance biopsy is furthered by the limitations of conventional renal functional studies. However, there is still much debate surrounding the surveillance biopsy in paediatric recipients, particularly in regard to its overall utility, safety and timing. This review discusses the current literature regarding the utility, safety, and potential predictive value of surveillance biopsies for guiding post-transplant management in paediatric renal allograft recipients, as well as the viability of other potentially newer non-invasive strategies for renal allograft monitoring. PMID:27306873

  2. Remote biopsy darting and marking of polar bears

    USGS Publications Warehouse

    Pagano, Anthony M.; Peacock, Elizabeth; McKinney, Melissa A.

    2014-01-01

    Remote biopsy darting of polar bears (Ursus maritimus) is less invasive and time intensive than physical capture and is therefore useful when capture is challenging or unsafe. We worked with two manufacturers to develop a combination biopsy and marking dart for use on polar bears. We had an 80% success rate of collecting a tissue sample with a single biopsy dart and collected tissue samples from 143 polar bears on land, in water, and on sea ice. Dye marks ensured that 96% of the bears were not resampled during the same sampling period, and we recovered 96% of the darts fired. Biopsy heads with 5 mm diameters collected an average of 0.12 g of fur, tissue, and subcutaneous adipose tissue, while biopsy heads with 7 mm diameters collected an average of 0.32 g. Tissue samples were 99.3% successful (142 of 143 samples) in providing a genetic and sex identification of individuals. We had a 64% success rate collecting adipose tissue and we successfully examined fatty acid signatures in all adipose samples. Adipose lipid content values were lower compared to values from immobilized or harvested polar bears, indicating that our method was not suitable for quantifying adipose lipid content.

  3. CT Guided Bone Biopsy Using a Battery Powered Intraosseous Device

    SciTech Connect

    Schnapauff, Dirk Marnitz, Tim Freyhardt, Patrick Collettini, Federico; Hartwig, Kerstin; Joehrens, Korinna; Hamm, Bernd Kroencke, Thomas Gebauer, Bernhard

    2013-10-15

    Purpose: To evaluate the feasibility of a battery powered intraosseous device to perform CT-fluoroscopy guided bone biopsy. Methods: Retrospective analysis of 12 patients in whom bone specimen were acquired from different locations under CT-fluoroscopy guidance using the OnControl bone marrow biopsy system (OBM, Vidacare, Shavano Park, TX, USA). Data of the 12 were compared to a historic cohort in whom the specimen were acquired using the classic Jamshidi Needle, as reference needle using manual force for biopsy. Results: Technical success was reached in 11 of 12 cases, indicated by central localisation of the needle within the target lesion. All specimen sampled were sufficient for histopathological workup. Compared to the historical cohort the time needed for biopsy decreased significantly from 13 {+-} 6 to 6 {+-} 4 min (P = 0.0001). Due to the shortened intervention time the radiation dose (CTDI) during CT-fluoroscopy was lowered significantly from 169 {+-} 87 to 111 {+-} 54 mGy Multiplication-Sign cm (P = 0.0001). Interventional radiologists were confident with the performance of the needle especially when using in sclerotic or osteoblastic lesions. Conclusion: The OBM is an attractive support for CT-fluoroscopy guided bone biopsy which is safe tool and compared to the classical approach using the Jamshidi needle leading to significantly reduced intervention time and radiation exposure.

  4. Laryngeal chondrosarcoma diagnosed by core-needle biopsy.

    PubMed

    Miyamaru, Satoru; Haba, Koichi

    2014-01-01

    We report a case of chondrosarcoma of the larynx, diagnosed by a percutaneous core-needle biopsy (CNB). Cartilaginous tumors of the larynx are usually diagnosed by biopsy with direct laryngomicroscopy under general anesthesia. However, patients find it difficult to undergo a biopsy under general anesthesia, for physical, economic, and social reasons. Instead, we can readily detect and sample tumors of the larynx using ultrasound under local anesthesia with reduced stress. Concerning needle-puncture biopsies, including fine-needle aspiration cytology (FNAC) and CNB, some studies have reported needle track dissemination, a possible complication in patients with malignant tumors. Thus, in the head and neck region, we generally use FNAC for biopsies, not CNB. However, it can be difficult to diagnose bone tumors by cytology alone. Regarding primary bone tumors, only one study has reported needle track dissemination by CNB, in osteosarcoma of the femur. Additionally, this complication has not been reported before with chondrosarcoma anywhere in the body. To our knowledge, this is the first report concerning chondrosarcoma of the larynx diagnosed by percutaneous CNB. We recommend CNB as a useful and safe diagnostic technique for primary bone tumors in the head and neck region.

  5. Renal biopsy: Still a landmark for the nephrologist.

    PubMed

    Visconti, Luca; Cernaro, Valeria; Ricciardi, Carlo Alberto; Lacava, Viviana; Pellicanò, Vincenzo; Lacquaniti, Antonio; Buemi, Michele; Santoro, Domenico

    2016-07-01

    Renal biopsy was performed for the first time more than one century ago, but its clinical use was routinely introduced in the 1950s. It is still an essential tool for diagnosis and choice of treatment of several primary or secondary kidney diseases. Moreover, it may help to know the expected time of end stage renal disease. The indications are represented by nephritic and/or nephrotic syndrome and rapidly progressive acute renal failure of unknown origin. Nowadays, it is performed mainly by nephrologists and radiologists using a 14-18 gauges needle with automated spring-loaded biopsy device, under real-time ultrasound guidance. Bleeding is the major primary complication that in rare cases may lead to retroperitoneal haemorrhage and need for surgical intervention and/or death. For this reason, careful evaluation of risks and benefits must be taken into account, and all procedures to minimize the risk of complications must be observed. After biopsy, an observation time of 12-24 h is necessary, whilst a prolonged observation may be needed rarely. In some cases it could be safer to use different techniques to reduce the risk of complications, such as laparoscopic or transjugular renal biopsy in patients with coagulopathy or alternative approaches in obese patients. Despite progress in medicine over the years with the introduction of more advanced molecular biology techniques, renal biopsy is still an irreplaceable tool for nephrologists. PMID:27458561

  6. Renal biopsy: Still a landmark for the nephrologist

    PubMed Central

    Visconti, Luca; Cernaro, Valeria; Ricciardi, Carlo Alberto; Lacava, Viviana; Pellicanò, Vincenzo; Lacquaniti, Antonio; Buemi, Michele; Santoro, Domenico

    2016-01-01

    Renal biopsy was performed for the first time more than one century ago, but its clinical use was routinely introduced in the 1950s. It is still an essential tool for diagnosis and choice of treatment of several primary or secondary kidney diseases. Moreover, it may help to know the expected time of end stage renal disease. The indications are represented by nephritic and/or nephrotic syndrome and rapidly progressive acute renal failure of unknown origin. Nowadays, it is performed mainly by nephrologists and radiologists using a 14-18 gauges needle with automated spring-loaded biopsy device, under real-time ultrasound guidance. Bleeding is the major primary complication that in rare cases may lead to retroperitoneal haemorrhage and need for surgical intervention and/or death. For this reason, careful evaluation of risks and benefits must be taken into account, and all procedures to minimize the risk of complications must be observed. After biopsy, an observation time of 12-24 h is necessary, whilst a prolonged observation may be needed rarely. In some cases it could be safer to use different techniques to reduce the risk of complications, such as laparoscopic or transjugular renal biopsy in patients with coagulopathy or alternative approaches in obese patients. Despite progress in medicine over the years with the introduction of more advanced molecular biology techniques, renal biopsy is still an irreplaceable tool for nephrologists. PMID:27458561

  7. Small Field of View Scintimammography Gamma Camera Integrated to a Stereotactic Core Biopsy Digital X-ray System

    SciTech Connect

    Andrew Weisenberger; Fernando Barbosa; T. D. Green; R. Hoefer; Cynthia Keppel; Brian Kross; Stanislaw Majewski; Vladimir Popov; Randolph Wojcik

    2002-10-01

    A small field of view gamma camera has been developed for integration with a commercial stereotactic core biopsy system. The goal is to develop and implement a dual-modality imaging system utilizing scintimammography and digital radiography to evaluate the reliability of scintimammography in predicting the malignancy of suspected breast lesions from conventional X-ray mammography. The scintimammography gamma camera is a custom-built mini gamma camera with an active area of 5.3 cm /spl times/ 5.3 cm and is based on a 2 /spl times/ 2 array of Hamamatsu R7600-C8 position-sensitive photomultiplier tubes. The spatial resolution of the gamma camera at the collimator surface is < 4 mm full-width at half-maximum and a sensitivity of /spl sim/ 4000 Hz/mCi. The system is also capable of acquiring dynamic scintimammographic data to allow for dynamic uptake studies. Sample images of preliminary clinical results are presented to demonstrate the performance of the system.

  8. Myocarditis confirmed by biopsy presenting as acute myocardial infarction.

    PubMed Central

    Costanzo-Nordin, M R; O'Connell, J B; Subramanian, R; Robinson, J A; Scanlon, P J

    1985-01-01

    Two cases of acute myocardial infarction occurred in association with myocarditis, which was confirmed by biopsy. The first patient suffered an anteroseptal and the second patient an inferior wall myocardial infarction shortly after an acute viral illness. In both patients, coronary angiography showed normal coronary arteries, and right ventricular endomyocardial biopsy confirmed myocarditis. Histological abnormalities attributable to ischaemic heart disease were absent. The first patient's condition became stable after immunosuppressive treatment. Myocarditis resolved spontaneously within three months in the second patient. Coronary artery spasm and myocardial involvement with a systemic disease were unlikely. Endomyocardial biopsy in patients with acute myocardial infarction and normal coronary arteries may be useful in identifying myocarditis associated with myocardial necrosis. Myocarditis in acute myocardial infarction in the absence of coronary artery obstruction has not previously been documented during life. Images PMID:3966948

  9. The role of renal biopsy in small renal masses.

    PubMed

    Burruni, Rodolfo; Lhermitte, Benoit; Cerantola, Yannick; Tawadros, Thomas; Meuwly, Jean-Yves; Berthold, Dominik; Jichlinski, Patrice; Valerio, Massimo

    2016-01-01

    Renal biopsy is being increasingly proposed as a diagnostic tool to characterize small renal masses (SRM). Indeed, the wide adoption of imaging in the diagnostic workup of many diseases had led to a substantial increased incidence of SRM (diameter ≤4 cm). While modern ultrasound, computed tomography (CT) and magnetic resonance imaging (MRI) techniques have high sensitivity for detecting SRM, none is able to accurately and reliably characterize them in terms of histological features. This is currently of key importance in guiding clinical decision-making in some situations, and in these cases renal biopsy should be considered. In this review, we aim to summarize the technique, diagnostic performance, and predicting factors of nondiagnostic biopsy, as well as the future perspectives.

  10. Percutaneous needle biopsy of the transplanted kidney: technique and complications.

    PubMed

    Huraib, S; Goldberg, H; Katz, A; Cardella, C J; deVeber, G A; Cook, G T; Uldall, P R

    1989-07-01

    Over 11 1/2 years, 420 percutaneous needle biopsies were obtained from the transplanted kidneys of 205 patients at one institution. The procedure was performed by one nephrologist and 55 nephrology trainees. No limit was placed on the number of biopsies performed on one kidney, and the highest number was seven. The complications were macroscopic hematuria in 28 biopsies, prolonged hematuria (greater than 24 hours) in eight, transient anuria in five, and prolonged anuria requiring surgical intervention in one. Perinephric hematoma occurred in three patients; retroperitoneal hematoma led to compression of the iliac vein in one. None of these complications led to loss of the transplant. It is suggested that the freedom from serious complication is related to the safety of the technique and the precautions applied to preparation of the patient. These are described in detail.

  11. Pericardial Tamponade: a Rare Complication of Sternal Bone Marrow Biopsy

    PubMed Central

    Santavy, Petr; Troubil, Martin; Lonsky, Vladimir

    2013-01-01

    Injury of the heart with concomitant pericardial tamponade as a result of sternal bone marrow biopsy is rare. An 80-year-old man was admitted with dehydration and non-specified abdominal pain to the regional hospital. Sternal aspiration biopsy was performed because of anemia and thrombocytopenia. Later on, because of the back pain, general weakness and blood pressure drop, an echocardiography examination was indicated. Pericardial fluid collection was found. Anticipated ascending aortic dissection was excluded on computed tomography scan, but pericardial fluid collection was confirmed. Transfer to our cardiac surgical facility ensued. Limited heart tamponade was affirmed on echocardiography and surgery was immediately indicated. Blood effusion was found in upper mediastinal fat tissue and 300 mL of blood were evacuated from opened pericardial space. Stab wound by sternal biopsy needle at the upper part of ascending aorta was repaired by pledgeted suture. Postoperative course was uneventful. PMID:24179668

  12. Sequential muscle biopsy changes in a case of congenital myopathy.

    SciTech Connect

    Danon, M. J.; Giometti, C. S.; Manaligod, J. R.; Swisher, C.; Center for Mechanistic Biology and Biotechnology; New York Medical Coll.; Univ. of Illinois at Chicago; Children's Memorial Hospital

    1997-05-01

    Muscle biopsies at age 7 months in a set of dizygotic male twins born floppy showed typical features of congenital fiber-type disproportion (CFTD). One of the twins died at age 1 year due to respiratory complications. The second one subsequently developed facial diplegia and external ophthalmoplegia. He never walked, remained wheelchair bound, and required continuous ventilatory support. He underwent repeat biopsies at ages 2 and 4, which showed many atrophic type 1 muscle fibers containing central nuclei and severe type 2 fiber deficiency compatible with centronuclear myopathy (CNM). Two-dimensional gel electrophoresis of muscle showed decreases of type II myosin light chains 2 and 3, suggestive of histochemical type I fiber deficiency. The progressive nature of morphological changes in one of our patients cannot be explained by maturational arrest. Repeat biopsies in cases of CFTD with rapid clinical deterioration may very well show CNM.

  13. Splitting and biopsy for bovine embryo sexing under field conditions.

    PubMed

    Lopes, R F; Forell, F; Oliveira, A T; Rodrigues, J L

    2001-12-01

    Improvements on embryo micromanipulation techniques led to the use of embryo bisection technology in commercial embryo transfer programs, and made possible the direct genetic analysis of preimplantation bovine embryos by biopsy. For example, aspiration and microsection, allow bovine embryos sexing by detection of male-specific Y-chromosome in a sample of embryonic cells. We report on the application of the methodologies of splitting and biopsy of bovine embryos in field conditions, and on the results of embryo sex determination by the polymerase chain reaction (PCR). Pregnancy rates achieved with fresh bisected or biopsied embryos (50 to 60%) were similar to the fresh intact embryos (55 to 61%). The PCR protocol used for embryo sexing showed 92% to 94% of efficiency and 90 to 100% of accuracy. These results demonstrate these procedures are suitable for use in field conditions.

  14. The role of renal biopsy in small renal masses

    PubMed Central

    Burruni, Rodolfo; Lhermitte, Benoit; Cerantola, Yannick; Tawadros, Thomas; Meuwly, Jean-Yves; Berthold, Dominik; Jichlinski, Patrice; Valerio, Massimo

    2016-01-01

    Renal biopsy is being increasingly proposed as a diagnostic tool to characterize small renal masses (SRM). Indeed, the wide adoption of imaging in the diagnostic workup of many diseases had led to a substantial increased incidence of SRM (diameter ≤4 cm). While modern ultrasound, computed tomography (CT) and magnetic resonance imaging (MRI) techniques have high sensitivity for detecting SRM, none is able to accurately and reliably characterize them in terms of histological features. This is currently of key importance in guiding clinical decision-making in some situations, and in these cases renal biopsy should be considered. In this review, we aim to summarize the technique, diagnostic performance, and predicting factors of nondiagnostic biopsy, as well as the future perspectives. PMID:26858784

  15. Fine needle aspiration biopsy in salivary gland tumours.

    PubMed

    Lau, T; Balle, V H; Bretlau, P

    1986-04-01

    Of 105 tumours of the major salivary glands, 90 were benign and 15 malignant. In benign tumours a correct preoperative diagnosis was made by fine needle aspiration biopsy in 84%, and none were falsely classed as malignant. In the malignant tumours, only 8 out of 15 (53%) were correctly diagnosed as malignant while 7 were misdiagnosed as benign. It is concluded that in benign salivary gland tumours there is good accordance between fine needle aspiration biopsy and the final histological report, in contrast to the malignant tumours where this is less convincing. Fine needle aspiration biopsy is a valuable diagnostic tool, but the result should be carefully evaluated, regarded as only part of the clinical picture and not solely relied on.

  16. IgG Subclass Staining in Routine Renal Biopsy Material.

    PubMed

    Hemminger, Jessica; Nadasdy, Gyongyi; Satoskar, Anjali; Brodsky, Sergey V; Nadasdy, Tibor

    2016-05-01

    Immunofluorescence staining plays a vital role in nephropathology, but the panel of antibodies used has not changed for decades. Further classification of immunoglobulin (Ig)G-containing immune-type deposits with IgG subclass staining (IgG1, IgG2, IgG3, and IgG4) has been shown to be of diagnostic utility in glomerular diseases, but their value in the evaluation of renal biopsies has not been addressed systematically in large renal biopsy material. Between January 2007 and June 2014, using direct immunofluorescence, we stained every renal biopsy for the IgG subclasses if there was moderate to prominent glomerular IgG staining and/or IgG-predominant or IgG-codominant glomerular staining. The total number of biopsies stained was 1084, which included 367 cases of membranous glomerulonephritis, 307 cases of lupus nephritis, 74 cases of fibrillary glomerulonephritis, 53 cases of proliferative glomerulonephritis with monoclonal IgG deposits, and 25 cases of antiglomerular basement membrane disease, among others. We found that monoclonality of IgG deposits cannot always be reliably determined on the basis of kappa and lambda light chain staining alone, particularly if concomitant (frequently nonspecific) IgM staining is present. In IgG heavy and heavy and light chain deposition disease (3 cases), subclass staining is very helpful, and in proliferative glomerulonephritis with monoclonal IgG deposits subclass staining is necessary. IgG subclass staining is useful in differentiating primary from secondary membranous glomerulonephritis. In proliferative glomerulonephritis with polyclonal IgG deposition, IgG1 dominance/codominance with concomitant IgG3 and IgG2 but weak or absent IgG4 staining favors an underlying autoimmune disease. IgG subclass staining is a very useful diagnostic method in a selected cohort of renal biopsies, particularly in biopsies with glomerulonephritis with monoclonal IgG deposits.

  17. [Hepatic puncture biopsy in ambulatory care. Advantages and disadvantages].

    PubMed

    Nouel, O

    1997-03-01

    There is a clear trend towards favoring outpatient care in an attempt to control health care costs. Despite widespread acceptance in some countries, many teams in France still prefer to hospitalize patients requiring percutaneous liver biopsy because the outpatient setting has not been encouraged in French text books on hepatology, many gastroenterologists do not have access to outpatient facilities, and the lack of French references which has raised questions as to the legal responsibilities involved. The series of 231 outpatient percutaneous liver biopsies reported by Bourgaux in this issue of La Presse Médicale will remove the doubt in many minds. There are many advantages for the generally young population with early stage liver disease, frequently hepatitis C, requiring percutaneous liver biopsy. Lower cost is probably the primary advantage, but improved patient comfort, especially if repeated procedures are needed, is also greatly appreciated. The outpatient procedure is safe when all the selection criteria are met including: normal coagulation, ultrasonographically homogeneous liver, patient compliance and availability of a structured outpatient clinic, and absence of a severe concomitent disease. These apparently restrictive criteria actually include the majority of the indications for liver biopsy. There is another debate on whether echo-guided biopsy would be even safer but as emphasized by Bourgaux et al. this would require a reorganization of most of the hepatogastroenterology departments. One other point cannot be overlooked. Some operators (and patients) may also feel that the impressive nature of the procedure merits a more impressive setting, i.e. full hospitalization. Consequently, while it is quite reasonable to propose outpatient liver biopsy as a classical procedure, there are situations when personal preference may still dictate hospitalization.

  18. Trans-rectal interventional MRI: initial prostate biopsy experience

    NASA Astrophysics Data System (ADS)

    Greenwood, Bernadette M.; Behluli, Meliha R.; Feller, John F.; May, Stuart T.; Princenthal, Robert; Winkel, Alex; Kaminsky, David B.

    2010-02-01

    Dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) of the prostate gland when evaluated along with T2-weighted images, diffusion-weighted images (DWI) and their corresponding apparent diffusion coefficient (ADC) maps can yield valuable information in patients with rising or elevated serum prostate-specific antigen (PSA) levels1. In some cases, patients present with multiple negative trans-rectal ultrasound (TRUS) biopsies, often placing the patient into a cycle of active surveillance. Recently, more patients are undergoing TRIM for targeted biopsy of suspicious findings with a cancer yield of ~59% compared to 15% for second TRUS biopsy2 to solve this diagnostic dilemma and plan treatment. Patients were imaged in two separate sessions on a 1.5T magnet using a cardiac phased array parallel imaging coil. Automated CAD software was used to identify areas of wash-out. If a suspicious finding was identified on all sequences it was followed by a second imaging session. Under MRI-guidance, cores were acquired from each target region3. In one case the microscopic diagnosis was prostatic intraepithelial neoplasia (PIN), in the other it was invasive adenocarcinoma. Patient 1 had two negative TRUS biopsies and a PSA level of 9ng/mL. Patient 2 had a PSA of 7.2ng/mL. He underwent TRUS biopsy which was negative for malignancy. He was able to go on to treatment for his prostate carcinoma (PCa)4. MRI may have an important role in a subset of patients with multiple negative TRUS biopsies and elevated or rising PSA.

  19. Renal biopsy findings in Belgium: a retrospective single center analysis.

    PubMed

    Mesquita, M; Fosso, C; Bakoto Sol, E; Libertalis, M; Corazza, F; Vanden Houte, K; Dratwa, M

    2011-01-01

    Renal biopsy is the definitive diagnostic test in patients with renal parenchymal disease. Renal biopsy registry is an important tool which can provide valuable data concerning early and correct epidemiological description and clinical correlations of renal diseases. Records of 326 adult renal biopsies performed at our hospital from January 1991 till the end of December 2006 were retrospectively examined. Overall, secondary glomerular diseases (SGD) were predominant (39.9%), followed by primary glomerular diseases (PGD) (30.4%), vascular diseases (13.2%) and TIN (6.7%). Total sclerosis of the kidney did not allow histopathological diagnosis in 5.8% of all biopsied kidneys. Focal and Segmental Glomerular Sclerosis (FSGS), IgA Nephropathy (IgAGN) and Minimal Change Disease (MCD) and Membranous Glomerulopathy (MGN) were the most common PGD, altogether representing 75.7% of all PGD. FSGS was the most frequent (30.3%), followed by IgAGN (21.2%), MCD (19.1%) and MGN in 15.1%. Vasculitis, HIVAN, diabetic nephropathy and amyloidosis were the most common SGD, altogether representing 90% of all SGD. Immune Mediated Glomerulonephritis (IMGN) were the most frequent (32.3%), followed by HIVAN (16.9%), diabetic nephropathy (14.6%) and amyloidosis (10%). Nephroangiosclerosis (benign and malignant nephroangiosclerosis) was the most frequent vascular nephropathy responsible for 79% of all vascular diseases. Thrombotic microangiopathy was seen in 9.3% and atherothrombotic disease in 7% of all vascular diseases. Concerning tubular diseases, chronic TIN accounted for 63.6% of all tubular diseases, followed by light chain-cast nephropathy (22.7%) and acute TIN (13.6%). Because of lack of material, 3.4% of all biopsies could not be analyzed. These data demonstrate that the distribution of biopsy-proved renal diseases in a Belgian population of the Brussels area is strongly influenced by the indications of renal biopsy. Harmonization of these indications might reflect with more accuracy

  20. Do we still need renal biopsy in lupus nephritis?

    PubMed

    Haładyj, Ewa; Cervera, Ricard

    2016-01-01

    The natural course of systemic lupus erythematosus (SLE) is characterized by periods of disease activity and remissions. Prolonged disease activity results in cumulative organ damage. Lupus nephritis is one of the most common and devastating manifestations of SLE. In the era of changing therapy to less toxic regimens, some authors have stated that if mycophenolate mofetil can be used for the induction and maintenance treatment in all histological classes of lupus nephritis, renal biopsy can be omitted. This article aims to answer the question of what brings the bigger risk: renal biopsy or its abandonment.

  1. Two cases of uterine malignant lymphoma diagnosed by needle biopsy

    PubMed Central

    Ichimura, Tomoyuki; Murakami, Makoto; Matsuda, Makiko; Kawamura, Naoki; Sumi, Toshiyuki

    2015-01-01

    Abstract The incidence of primary malignant lymphoma arising in the female genital tract is extremely rare and constitutes approximately 0.05% of malignant tumors. Uterine malignant lymphoma develops in the endometrial stroma, causing minimal necrosis. It is therefore difficult to diagnose malignant lymphoma, as it does not involve genital bleeding or epithelial defects. We have performed transcervical needle biopsies from deep in the myometrium, with the purpose of diagnosing uterine muscle layer lesions, such as leiomyosarcoma, but this is an unusual method. In this report, we suggest that transcervical needle biopsy is useful in the diagnosis of uterine malignant lymphoma. PMID:26370331

  2. Altered coagulability: an aid to selective breast biopsy.

    PubMed Central

    Spillert, C. R.; Passannante, M. R.; Salzer-Pagan, J. E.; Lazaro, E. J.

    1993-01-01

    Difficulty in discriminating nonadvanced breast cancer from benign breast disease results in many cancer negative biopsies. Development of a test to better differentiate between these two entities to reduce the number of cancer negative biopsies was the purpose of this blind study. The clue that prompted the development of this test resides in the state of hypercoagulability in cancer. Hypercoagulability can be measured by assessing tissue factor-mediated altered coagulability. The amount of tissue factor release is contingent on prior activation of the monocyte (the only blood cell that generates tissue factor) in vivo. PMID:8478968

  3. MR guided breast interventions: role in biopsy targeting and lumpectomies

    PubMed Central

    Jagadeesan, Jayender; Richman, Danielle M; Kacher, Daniel F

    2015-01-01

    Synopsis Contrast enhanced breast MRI is increasingly being used to diagnose breast cancer and to perform biopsy procedures. The American Cancer Society has advised women at high risk for breast cancer to have breast MRI screening as an adjunct to screening mammography. This article places special emphasis on biopsy and operative planning involving MRI and reviews utility of breast MRI in monitoring response to neoadjuvant chemotherapy. We describe peer-reviewed data on currently accepted MR-guided therapeutic methods for addressing benign and malignant breast diseases, including intraoperative imaging. PMID:26499274

  4. Ileal Pouch Biopsy Triggers Investigation and Diagnosis of Systemic Mastocytosis

    PubMed Central

    Mannan, Abul Ala Syed Rifat; Shen, Bo; Hsieh, Fred; Patil, Deepa T.

    2016-01-01

    We report a unique case of systemic mastocytosis (SM) diagnosed in an ileal pouch biopsy obtained from a 44-year-old woman with ulcerative colitis. She presented with intermittent abdominal pain and watery diarrhea that did not respond to antibiotic therapy. The pouch biopsy showed expansion of the lamina propria by aggregates of CD117 and CD25-positive abnormal mast cells. A subsequent bone marrow analysis showed an increase in abnormal mast cells. Based on World Health Organization criteria, she was diagnosed with SM and responded to cromolyn sodium therapy. Systemic mastocytosis can mimic pouchitis, and thus recognition of this condition is important for appropriate clinical management. PMID:27807556

  5. A survey of oral biopsies in Brazilian pediatric patients.

    PubMed

    Maia, D M; Merly, F; Castro, W H; Gomez, R S

    2000-01-01

    This paper presents a review of 1018 oral biopsies in pediatric patients from the Oral Pathology Service, Minas Gerais Federal University, Brazil. The lesions were divided into ten main categories. The most common oral lesions in this study were follicular cyst in the maxillary anterior region, followed by inflammatory fibrous hyperplasia in the same region, and mucocele in the lower lip. Cysts of the jaws and oral soft tissues comprised 26.1 percent of total oral biopsies. The importance of these findings in oral diagnosis is discussed. PMID:10826049

  6. Transjugular Renal Biopsy: Our Experience and Technical Considerations

    SciTech Connect

    See, Teik Choon; Thompson, Barbara C.; Howie, Alexander J.; Karamshi, M.; Papadopoulou, Anthie M.; Davies, Neil; Tibballs, Jonathan

    2008-09-15

    The purpose of this study was to describe the indications for and technique of transjugular renal biopsy (TJRB) and evaluate the efficacy and complications of this method. We performed a retrospective review of 59 patients who underwent TJRB using the Quick-core needle biopsy system (Cook, Letchworth, UK) over a 4-year period. The indications for obtaining renal biopsy included acute renal failure, chronic renal failure, nephrotic syndrome, and proteinuria with or without other associated disease. Indications for the transjugular approach included coagulopathy, biopsy of a solitary kidney or essentially single functioning kidney, simultaneous renal and hepatic biopsy, morbid obesity, and failed percutaneous biopsy. All but four cases were performed via the right internal jugular vein. The right, left, or both renal veins were cannulated in 41, 14, and 4 cases, respectively. Combined liver and renal biopsies were obtained in seven cases. Diagnostic biopsy specimens were obtained in 56 of 59 patients (95%). The number and size of tissue cores ranged from 1 to 9 mm and from 1 to 20 mm, respectively. The mean numbers of glomeruli per procedure on light microscopy and electron microscopy were 10.3 and 2.6, respectively. Specimens for immunohistology were acquired in 49 cases, of which 40 were adequate. Of the 56 successful TJRB procedures, 34 (61%) were associated with isolated capsular perforation (19), contained subcapsular leak (10), isolated collecting system puncture (1), and concurrent collecting system and capsular perforation (4). There was a significant increase in capsular perforation with six or more needle passes, although no significant correlation was seen between number of needle passes and complication. Six patients had minor complications defined as hematuria or loin pain. Seven patients developed major complications, of whom five received blood transfusion alone. Two required intervention: in one an arteriocalyceal fistula was embolized and the patient

  7. Do we still need renal biopsy in lupus nephritis?

    PubMed Central

    Cervera, Ricard

    2016-01-01

    The natural course of systemic lupus erythematosus (SLE) is characterized by periods of disease activity and remissions. Prolonged disease activity results in cumulative organ damage. Lupus nephritis is one of the most common and devastating manifestations of SLE. In the era of changing therapy to less toxic regimens, some authors have stated that if mycophenolate mofetil can be used for the induction and maintenance treatment in all histological classes of lupus nephritis, renal biopsy can be omitted. This article aims to answer the question of what brings the bigger risk: renal biopsy or its abandonment. PMID:27407281

  8. Internal mammary lymph node biopsy guided by computed tomography

    PubMed Central

    Irving, Henry C.; Hardy, Graham J.

    1982-01-01

    Internal mammary lymph node enlargement may be demonstrated using computed tomography (CT), and a confirmatory tissue diagnosis of metastatic involvement may be obtained using fine needle aspiration biopsy with needle tip placement guided by the CT scanner. A case history is described to illustrate how a patient presented 9 years after mastectomy with an internal mammary lymph node metastasis and how cytopathological diagnosis of this metastasis was achieved by CT guided biopsy. ImagesFig. 1Fig. 2Fig. 3Fig. 4 PMID:7145793

  9. Diagnosis of salivary gland tumors by fine needle aspiration biopsy.

    PubMed

    Sismanis, A; Merriam, J M; Kline, T S; Davis, R K; Shapshay, S M; Strong, M S

    1981-01-01

    The cytologic findings of 51 smears obtained by fine needle aspiration biopsy from salivary gland masses were compared with the histologic findings of permanent sections. The overall concurrence rate between cytologic and histologic findings for being and malignant lesions was 91%. The diagnostic accuracy (exact histologic diagnosis) for the benign lesions was 87% and for the malignant tumors 60%. One case showed false-positive results and 1 case false-negative results. Fine needle aspiration biopsy has been found to be safe, free of complications, and helpful in the planning of treatment.

  10. [Biopsy of suspicious lesions in patients with breast cancer].

    PubMed

    Colin, P-E; Schroeder, H; Gonne, E; Hanocq, F; André, C; Rorive, A; Jerusalem, G; Collignon, J

    2015-11-01

    Discordances between hormone receptors and HER2 status in primary and metastatic breast cancer have been reported by several studies. In this context, systematic biopsies could be clinically relevant in breast cancer to confirm the biological characteristics of a suspicious lesion. In this article, illustrated by 2 case reports and based on a recent review on this topic, we discuss the clinical significance of receptor discordances and possible diagnosis of a secondary primary tumor. The role of these biopsies for the identification of new therapeutic targets is also envisaged as well as underlying mechanisms for receptors' modification like tumoral heterogeneity, clonal selection and technical artifacts. PMID:26738268

  11. The pros and cons of outpatient breast biopsy.

    PubMed

    Lou, M A; Mandal, A K; Alexander, J L

    1976-06-01

    A review of the 130 breast biopsies performed on women during the past three years at the Martin Luther King, Jr, General Hospital showed that 90 were performed on outpatients and 40 on inpatients. Of the 90 outpatient procedures, 61 were under local anesthesia and 29 under general. Only three outpatient biopsy specimens were malignant and required subsequent patient admission to the hospital for mastectomy at an interval of 9 to 14 days. In all three, the axillary nodes were uninvolved. In two, no residual tumor was found in the mastectomy specimen.

  12. Sensitivity of PCR Targeting Mycobacterium ulcerans by Use of Fine-Needle Aspirates for Diagnosis of Buruli Ulcer▿

    PubMed Central

    Phillips, R. O.; Sarfo, F. S.; Osei-Sarpong, F.; Boateng, A.; Tetteh, I.; Lartey, A.; Adentwe, E.; Opare, W.; Asiedu, K. B.; Wansbrough-Jones, M.

    2009-01-01

    In a previous study, we reported that the sensitivity of PCR targeting the IS2404 insertion sequence of Mycobacterium ulcerans was 98% when it was applied to 4-mm punch biopsy samples of Buruli lesions. Fine-needle aspiration (FNA) is a less traumatic sampling technique for nonulcerated lesions, and we have studied the sensitivity of PCR using FNA samples. Fine-needle aspirates were taken with a 21-gauge needle from 43 patients diagnosed clinically with M. ulcerans disease. Four-millimeter punch biopsies were obtained for microscopy, culture, and PCR targeting the IS2404 insertion sequence. The sensitivity of PCR using samples obtained by FNA was 86% (95% confidence interval [95% CI], 72 to 94%) compared with that for PCR using punch biopsy samples. In this study, the sensitivities of culture and microscopy for punch biopsy samples were 44% (95% CI, 29 to 60%) and 26% (95% CI, 14 to 41%), respectively. This demonstrates that PCR on an FNA sample is a viable minimally invasive technique to diagnose M. ulcerans lesions. PMID:19204098

  13. Evaluation of neutrophil-to-lymphocyte ratio prior to prostate biopsy to predict biopsy histology: Results of 1836 patients

    PubMed Central

    Gokce, Mehmet Ilker; Hamidi, Nurullah; Suer, Evren; Tangal, Semih; Huseynov, Adil; Ibiş, Arif

    2015-01-01

    Introduction: We evaluate the role of NLR prior to prostate biopsy to predict biopsy histology and Gleason score in patients with prostate cancer. Methods: In this retrospective study, we evaluated data of patients underwent prostate biopsy between May 2005 and March 2015. We collected the following data: age, prostate-specific antigen (PSA), biopsy histology, Gleason score (GS) in prostate cancer patients, neutrophil counts, and lymphocyte counts. Patients were grouped as benign prostatic hyperplasia (BPH), prostate cancer, and prostatitis. The Chi square test was used to compare categorical variables and analysis of variance (ANOVA) was applied for continuous variables. Results: Data of 1836 patients were investigated. The mean age, total PSA and neutrophil-lymphocyte ratio (NLR) of the population were 66.8 ± 8.17 years, 9.38 ± 4.7 ng/dL, and 3.11 ± 1.71, respectively. Patients were divided as follows: 625 in the group with BPH history, 600 in the prostatitis group, and 611 in the prostate cancer histology group. The mean NLR of the prostatitis group was higher compared to the prostate cancer and BPH groups (p = 0.0001). The mean NLR of the prostate cancer group was significantly higher compared to the BPH group (p = 0.002). The GS 8–10 group had a significantly higher mean NLR compared to GS 5–6 (3.64 vs. 2.54, p = 0.0001) and GS 7 (3.64 vs. 2.58, p = 0.0001) patients. Conclusions: NLR was found to differ with regard to histology of prostate biopsy and higher GS was associated with higher NLR in patients with prostate cancer. However prostatitis prevents the use of NLR in predicting prostate cancer before a prostate biopsy. Also, the retrospective nature and lack of multivariate analysis in this study somewhat limits the relevance of these results. PMID:26600880

  14. Evaluating The PCPT Risk Calculator in Ten International Biopsy Cohorts: Results from the Prostate Biopsy Collaborative Group

    PubMed Central

    Ankerst, Donna P.; Boeck, Andreas; Freedland, Stephen J.; Thompson, Ian M.; Cronin, Angel M.; Roobol, Monique J.; Hugosson, Jonas; Jones, J. Stephen; Kattan, Michael W.; Klein, Eric A.; Hamdy, Freddie; Neal, David; Donovan, Jenny; Parekh, Dipen J.; Klocker, Helmut; Horninger, Wolfgang; Benchikh, Amine; Salama, Gilles; Villers, Arnauld; Moreira, Daniel M.; Schröder, Fritz H.; Lilja, Hans; Vickers, Andrew J.

    2013-01-01

    Objectives To evaluate the discrimination, calibration and net benefit performance of the Prostate Cancer Prevention Trial Risk Calculator (PCPTRC) across five European Randomized study of Screening for Prostate Cancer (ERSPC), 1 United Kingdom, 1 Austrian and 3 US biopsy cohorts. Methods PCPTRC risks were calculated for 25,733 biopsies using prostate-specific antigen (PSA), digital rectal examination, family history and history of prior biopsy, and single imputation for missing covariates. Predictions were evaluated using the areas underneath the receiver operating characteristic curves (AUC), discrimination slopes, chi-square tests of goodness of fit, and net benefit decision curves. Results AUCs of the PCPTRC ranged from a low of 56% in the ERSPC Goeteborg Rounds 2-6 cohort to a high of 72% in the ERSPC Goeteborg Round 1 cohort, and were statistically significantly higher than that of PSA in 6 out of the 10 cohorts. The PCPTRC was well-calibrated in the SABOR, Tyrol and Durham cohorts. There was limited to no net benefit to using the PCPTRC for biopsy referral compared to biopsying all or no men in all five ERSPC cohorts and benefit within a limited range of risk thresholds in all other cohorts. Conclusions External validation of the PCPTRC across ten cohorts revealed varying degree of success highly dependent on the cohort, most likely due to different criteria for and work-up before biopsy. Future validation studies of new calculators for prostate cancer should acknowledge the potential impact of the specific cohort studied when reporting successful versus failed validation. PMID:22210512

  15. Comparison of prostate MRI-3D transrectal ultrasound fusion biopsy for first-time and repeat biopsy patients with previous atypical small acinar proliferation

    PubMed Central

    Cool, Derek W.; Romagnoli, Cesare; Izawa, Jonathan I.; Chin, Joseph; Gardi, Lori; Tessier, David; Mercado, Ashley; Mandel, Jonathan; Ward, Aaron D.; Fenster, Aaron

    2016-01-01

    Introduction: This study evaluates the clinical benefit of magnetic resonance-transrectal ultrasound (MR-TRUS) fusion biopsy over systematic biopsy between first-time and repeat prostate biopsy patients with prior atypical small acinar proliferation (ASAP). Materials: 100 patients were enrolled in a single-centre prospective cohort study: 50 for first biopsy, 50 for repeat biopsy with prior ASAP. Multiparameteric magnetic resonance imaging (MP-MRI) and standard 12-core ultrasound biopsy (Std-Bx) were performed on all patients. Targeted biopsy using MRI-TRUS fusion (Fn-Bx) was performed f suspicious lesions were identified on the pre-biopsy MP-MRI. Classification of clinically significant disease was assessed independently for the Std-Bx vs. Fn-Bx cores to compare the two approaches. Results: Adenocarcinoma was detected in 49/100 patients (26 first biopsy, 23 ASAP biopsy), with 25 having significant disease (17 first, 8 ASAP). Fn-Bx demonstrated significantly higher per-core cancer detection rates, cancer involvement, and Gleason scores for first-time and ASAP patients. However, Fn-Bx was significantly more likely to detect significant cancer missed on Std-Bx for ASAP patients than first-time biopsy patients. The addition of Fn-Bx to Std-Bx for ASAP patients had a 166.7% relative risk reduction for missing Gleason ≥ 3 + 4 disease (number needed to image with MP-MRI=10 patients) compared to 6.3% for first biopsy (number to image=50 patients). Negative predictive value of MP-MRI for negative biopsy was 79% for first-time and 100% for ASAP patients, with median followup of 32.1 ± 15.5 months. Conclusions: MR-TRUS Fn-Bx has a greater clinical impact for repeat biopsy patients with prior ASAP than biopsy-naïve patients by detecting more significant cancers that are missed on Std-Bx. PMID:27800057

  16. Image guided versus palpation guided core needle biopsy of palpable breast masses: a prospective study

    PubMed Central

    Hari, Smriti; Kumari, Swati; Srivastava, Anurag; Thulkar, Sanjay; Mathur, Sandeep; Veedu, Prasad Thotton

    2016-01-01

    Background & objectives: Biopsy of palpable breast masses can be performed manually by palpation guidance or under imaging guidance. Based on retrospective studies, image guided biopsy is considered more accurate than palpation guided breast biopsy; however, these techniques have not been compared prospectively. We conducted this prospective study to verify the superiority and determine the size of beneficial effect of image guided biopsy over palpation guided biopsy. Methods: Over a period of 18 months, 36 patients each with palpable breast masses were randomized into palpation guided and image guided breast biopsy arms. Ultrasound was used for image guidance in 33 patients and mammographic (stereotactic) guidance in three patients. All biopsies were performed using 14 gauge automated core biopsy needles. Inconclusive, suspicious or imaging-histologic discordant biopsies were repeated. Results: Malignancy was found in 30 of 36 women in palpation guided biopsy arm and 27 of 36 women in image guided biopsy arm. Palpation guided biopsy had sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of 46.7, 100, 100, 27.3 per cent, respectively, for diagnosing breast cancer. Nineteen of 36 women (52.8%) required repeat biopsy because of inadequate samples (7 of 19), suspicious findings (2 of 19) or imaging-histologic discordance (10 of 19). On repeat biopsy, malignancy was found in all cases of imaging-histologic discordance. Image guided biopsy had 96.3 per cent sensitivity and 100 per cent specificity. There was no case of inadequate sample or imaging-histologic discordance with image guided biopsy. Interpretation & conclusions: Our results showed that in palpable breast masses, image guided biopsy was superior to palpation guided biopsy in terms of sensitivity, false negative rate and repeat biopsy rates. PMID:27488003

  17. Percutaneous biopsy for risk stratification of renal masses.

    PubMed

    Blute, Michael L; Drewry, Anna; Abel, Edwin Jason

    2015-10-01

    The increased use of abdominal imaging has led to identification of more patients with incidental renal masses, and renal mass biopsy (RMB) has become a popular method to evaluate unknown renal masses prior to definitive treatment. Pathologic data obtained from biopsy may be used to guide decisions for treatment and may include the presence or absence of malignant tumor, renal cell cancer subtype, tumor grade and the presence of other aggressive pathologic features. However, prior to using RMB for risk stratification, it is important to understand whether RMB findings are equivalent to pathologic analysis of surgical specimens and to identify any potential limitations of this approach. This review outlines the advantages and limitations of the current studies that evaluate RMB as a guide for treatment decision in patients with unknown renal masses. In multiple series, RMB has demonstrated low morbidity and a theoretical reduction in cost, if patients with benign tumors are identified from biopsy and can avoid subsequent treatment. However, when considering the routine use of RMB for risk stratification, it is important to note that biopsy may underestimate risk in some patients by undergrading, understaging or failing to identify aggressive tumor features. Future studies should focus on developing treatment algorithms that integrate RMB to identify the optimal use in risk stratification of patients with unknown renal masses.

  18. Optical spectroscopy for stereotactic biopsy of brain tumors

    NASA Astrophysics Data System (ADS)

    Markwardt, Niklas; von Berg, Anna; Fiedler, Sebastian; Goetz, Marcus; Haj-Hosseini, Neda; Polzer, Christoph; Stepp, Herbert; Zelenkov, Petr; Rühm, Adrian

    2015-07-01

    Stereotactic biopsy procedure is performed to obtain a tissue sample for diagnosis purposes. Currently, a fiber-based mechano-optical device for stereotactic biopsies of brain tumors is developed. Two different fluorophores are employed to improve the safety and reliability of this procedure: The fluorescence of intravenously applied indocyanine green (ICG) facilitates the recognition of blood vessels and thus helps minimize the risk of cerebral hemorrhages. 5- aminolevulinic-acid-induced protoporphyrin IX (PpIX) fluorescence is used to localize vital tumor tissue. ICG fluorescence detection using a 2-fiber probe turned out to be an applicable method to recognize blood vessels about 1.5 mm ahead of the fiber tip during a brain tumor biopsy. Moreover, the suitability of two different PpIX excitation wavelengths regarding practical aspects was investigated: While PpIX excitation in the violet region (at 405 nm) allows for higher sensitivity, red excitation (at 633 nm) is noticeably superior with regard to blood layers obscuring the fluorescence signal. Contact measurements on brain simulating agar phantoms demonstrated that a typical blood coverage of the tumor reduces the PpIX signal to about 75% and nearly 0% for 633 nm and 405 nm excitation, respectively. As a result, 633 nm seems to be the wavelength of choice for PpIX-assisted detection of high-grade gliomas in stereotactic biopsy.

  19. [Sentinel lymph node biopsy in pregnancy-associated breast cancer].

    PubMed

    Mátrai, Zoltán; Bánhidy, Ferenc; Téglás, Melinda; Kovács, Eszter; Sávolt, Akos; Udvarhelyi, Nóra; Bartal, Alexandra; Kásler, Miklós

    2013-12-01

    The incidence of pregnancy-associated breast cancer is rising. Sentinel lymph node biopsy is the method of choice in clinically node negative cases as the indicated minimally invasive regional staging procedure. Some reports have linked radioisotope and blue dye required for lymphatic mapping to teratogenic effects, the idea of which has become a generalized statement and, until recently, contraindication for these agents was considered during pregnancy. Today, there are many published reports of successful interventions with low-dose 99mTc-labeled human albumin nanocolloid, based on dosimetric modeling demonstrating a negligible radiation exposure of the fetus. These results contributed to the seemingly safe and successful use of sentinel lymph node biopsy during pregnancy, though generally it can not replace axillary lymphadenectomy in the absence of high-quality evidence. The possibility of sentinel lymph node biopsy should be offered to pregnancy-associated early breast cancer patients with clinically negative axilla, and patients should be involved in the decision making following extensive counselling. This paper presents the successful use of sentinel lymph node biopsy with low-dose tracer during two pregnancies (in the first and third trimesters) and, for the first time in Hungarian language, it offers a comprehensive literature review on this topic. Orv. Hetil., 154(50), 1991-1997. PMID:24317358

  20. 21 CFR 870.4075 - Endomyocardial biopsy device.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Endomyocardial biopsy device. 870.4075 Section 870.4075 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... procedure to remove samples of tissue from the inner wall of the heart. (b) Classification. Class...

  1. 21 CFR 870.4075 - Endomyocardial biopsy device.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Endomyocardial biopsy device. 870.4075 Section 870.4075 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... procedure to remove samples of tissue from the inner wall of the heart. (b) Classification. Class...

  2. 21 CFR 870.4075 - Endomyocardial biopsy device.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Endomyocardial biopsy device. 870.4075 Section 870.4075 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... procedure to remove samples of tissue from the inner wall of the heart. (b) Classification. Class...

  3. 21 CFR 870.4075 - Endomyocardial biopsy device.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Endomyocardial biopsy device. 870.4075 Section 870.4075 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... procedure to remove samples of tissue from the inner wall of the heart. (b) Classification. Class...

  4. 21 CFR 870.4075 - Endomyocardial biopsy device.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Endomyocardial biopsy device. 870.4075 Section 870.4075 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... procedure to remove samples of tissue from the inner wall of the heart. (b) Classification. Class...

  5. Biopsy of parotid masses: Review of current techniques

    PubMed Central

    Haldar, Sananda; Sinnott, Joseph D; Tekeli, Kemal M; Turner, Samuel S; Howlett, David C

    2016-01-01

    Definitive diagnosis of parotid gland masses is required optimal management planning and for prognosis. There is controversy over whether fine needle aspiration cytology (FNAC) or ultrasound guided core biopsy (USCB) should be the standard for obtaining a biopsy. The aim of this review is to assess the current evidence available to assess the benefits of each technique and also to assess the use of intra-operative frozen section (IOFS). Literature searches were performed using pubmed and google scholar. The literature has been reviewed and the evidence is presented. FNAC is an accepted and widely used technique. It has been shown to have variable diagnostic capabilities depending on centres and experience of staff. USCB has a highly consistent diagnostic accuracy and can help with tumour grading and staging. However, the technique is more invasive and there is a question regarding potential for seeding. Furthermore, USCB is less likely to be offered as part of a one-stop clinic. IOFS has no role as a first line diagnostic technique but may be reserved as an adjunct or for lesions not amenable to percutaneous biopsy. On balance, USCB seems to be the method of choice. The current evidence suggests it has superior diagnostic potential and is safe. With time, USCB is likely to supplant FNAC as the biopsy technique of choice, replicating that which has occurred already in other areas of medicine such a breast practice. PMID:27247715

  6. Radial Scar at Image-guided Needle Biopsy

    PubMed Central

    Conlon, Niamh; D’Arcy, Clare; Kaplan, Jennifer B.; Bowser, Zenica L.; Cordero, Anibal; Brogi, Edi; Corben, Adriana D.

    2016-01-01

    Optimal management of a lesion yielding radial scar (RS) without epithelial atypia on breast biopsy is controversial. In this single-institution study spanning 17 years, 53 patients with this biopsy diagnosis were evaluated in terms of clinical, radiologic, and pathologic features and outcomes. RSs were categorized as either “incidental” or as the “targeted” lesion according to defined criteria. Of 48 patients who underwent surgical excision after a diagnosis of RS on biopsy, only 1 had an “upgrade” diagnosis of malignancy (2%). No “incidental” RS was associated with the presence of malignancy on surgical excision. Meta-analysis of 20 RS excision studies demonstrated an overall upgrade rate of 10.4%, with a higher rate in patients with a diagnosis of RS with atypia (26%). The upgrade rate for RS without atypia was 7.5% overall. The lower rate of upgrade to malignancy in this study (2%) is likely related to the thorough radiologic-pathologic review undertaken. In the setting of multidisciplinary agreement and careful radiologic-pathologic correlation, it may be appropriate for patients with a biopsy diagnosis of RS without atypia to forego surgical excision in favor of imaging follow-up. PMID:25634748

  7. [Experience in teaching a biopsy-section course in Belarus].

    PubMed

    Krylov, Yu V; Malashenko, S V; Lesnichaya, O V; Krylov, A Yu

    2015-01-01

    The paper deals with the improvement of teaching a biopsy-section course (BSC). The authors have analyzed the most frequent errors in the interaction of clinicians with a pathology service and summed up the experience of the Pathological Anatomy Department in practical work and teaching the BSC. The differentiated approach to teaching the BSC to resident students of different specialties is proposed.

  8. [Recurrent breast haematoma after fine needle aspiration biopsy of angiosarcoma].

    PubMed

    Ortiz Mendoza, Carlos Manuel

    2007-03-01

    It is reported a rare complication after a fine needle aspiration biopsy of a breast angiosarcoma. A 30-years-old female presented with a right breast lump. An ovoid, hypoecoic lesion of 39 x 13 mm was detect by ultrasonography. A fine needle aspiration biopsy was carried out for diagnosis, but only blood was report. After the biopsy the skin showed a violaceous color, the lump was tender, reappeared in three instances and increased its size (15 cm). In spite of conservative management the pain and the mass did not disappear, then surgical management was decided. A soft, violaceous mass of 13 x 6 x 4 cm, with well demarcated boundaries was removed. A capillary and cavernous breast hemangioma was diagnosed. Four months later a recurrence presented, and a new excision was carried out with a resulting moderately differentiated angiosarcoma, then a simple mastectomy was performed for definitive treatment. On a literature search only one similar case was found. A recurrent haematoma after a fine needle aspiration biopsy of a breast tumor mandates to rule out an angiosarcoma.

  9. The value of forceps biopsy and core needle biopsy in prediction of pathologic complete remission in locally advanced rectal cancer treated with neoadjuvant chemoradiotherapy.

    PubMed

    Tang, Jing-Hua; An, Xin; Lin, Xi; Gao, Yuan-Hong; Liu, Guo-Chen; Kong, Ling-Heng; Pan, Zhi-Zhong; Ding, Pei-Rong

    2015-10-20

    Patients with pathological complete remission (pCR) after treated with neoadjuvant chemoradiotherapy (nCRT) have better long-term outcome and may receive conservative treatments in locally advanced rectal cancer (LARC). The study aimed to evaluate the value of forceps biopsy and core needle biopsy in prediction of pCR in LARC treated with nCRT. In total, 120 patients entered this study. Sixty-one consecutive patients received preoperative forceps biopsy during endoscopic examination. Ex vivo core needle biopsy was performed in resected specimens of another 43 consecutive patients. The accuracy for ex vivo core needle biopsy was significantly higher than forceps biopsy (76.7% vs. 36.1%; p < 0.001). The sensitivity for ex vivo core needle biopsy was significantly lower in good responder (TRG 3) than poor responder (TRG ≤ 2) (52.9% vs. 94.1%; p = 0.017). In vivo core needle biopsy was further performed in 16 patients with good response. Eleven patients had residual cancer cells in final resected specimens, among whom 4 (36.4%) patients were biopsy positive. In conclusion, routine forceps biopsy was of limited value in identifying pCR after nCRT. Although core needle biopsy might further identify a subset of patients with residual cancer cells, the accuracy was not substantially increased in good responders.

  10. Single-Institution Results of Image-Guided Nonplugged Percutaneous Versus Transjugular Liver Biopsy

    SciTech Connect

    Hardman, Rulon L.; Perrich, Kiley D.; Silas, Anne M.

    2011-04-15

    Purpose: To retrospectively review patients who underwent transjugular and image-guided percutaneous biopsy and compare the relative risk of ascites, thrombocytopenia, and coagulopathy. Materials and Methods: From August 2001 through February 2006, a total of 238 liver biopsies were performed. The radiologist reviewed all patient referrals for transjugular biopsy. These patients either underwent transjugular biopsy or were reassigned to percutaneous biopsy (crossover group). Patients referred to percutaneous image-guided liver biopsy underwent this same procedure. Biopsies were considered successful if a tissue diagnosis could be made from the samples obtained. Results: A total of 36 transjugular biopsies were performed with 3 total (8.3%) and 1 major (2.8%) complications. A total of 171 percutaneous biopsies were performed with 10 (5.8%) total and 3 (1.8%) major complications. The crossover group showed a total of 4 (12.9%) complications with 1 (3.2%) major complication. Sample adequacy was 91.9% for transjugular and 99.5% for percutaneous biopsy. Conclusion: Both transjugular and percutaneous liver biopsy techniques are efficacious and safe. Contraindications such as thrombocytopenia, coagulopathy, and ascites are indicators of greater complications but are not necessarily prevented by transjugular biopsy. Percutaneous biopsy more frequently yields a diagnostic specimen than transjugular biopsy.

  11. Diabetic nephropathy: Is it time yet for routine kidney biopsy?

    PubMed Central

    Gonzalez Suarez, Maria L; Thomas, David B; Barisoni, Laura; Fornoni, Alessia

    2013-01-01

    Diabetic nephropathy (DN) is one of the most important long-term complications of diabetes. Patients with diabetes and chronic kidney disease have an increased risk of all-cause mortality, cardiovascular mortality, and kidney failure. The clinical diagnosis of DN depends on the detection of microalbuminuria. This usually occurs after the first five years from the onset of diabetes, and predictors of DN development and progression are being studied but are not yet implemented into clinical practice. Diagnostic tests are useful tools to recognize onset, progression and response to therapeutic interventions. Microalbuminuria is an indicator of DN, and it is considered the only noninvasive marker of early onset. However, up to now there is no diagnostic tool that can predict which patients will develop DN before any damage is present. Pathological renal injury is hard to predict only with clinical and laboratory findings. An accurate estimate of damage in DN can only be achieved by the histological analysis of tissue samples. At the present time, renal biopsy is indicated on patients with diabetes under the suspicion of the presence of nephropathies other than DN. Results from renal biopsies in patients with diabetes had made possible the classification of renal biopsies in three major groups associated with different prognostic features: diabetic nephropathy, non-diabetic renal disease (NDRD), and a superimposed non-diabetic condition on underlying diabetic nephropathy. In patients with type 2 diabetes with a higher degree of suspicion for NDRD, it is granted the need of a renal biopsy. It is important to identify and differentiate these pathologies at an early stage in order to prevent progression and potential complications. Therefore, a more extensive use of biopsy is advisable. PMID:24379914

  12. Kidney biopsy in west of Iran: Complications and histopathological findings

    PubMed Central

    Rahbar, M.

    2009-01-01

    In this retrospective study, we reviewed the medical records and histopathology findings of 135 patients who underwent renal biopsies at two special hospitals affiliated to Kermanshah medical university during a six-year period (2003-2007). All were performed using Tru-Cut needle under ultrasound guidance. Twenty four specimens were unsatisfactory. There were 38 males (34.2%) and 73 females (65.7%) in 111 patients with adequate specimens (each specimen has more than 5 glomeruli); the mean age was 16.5 years (range 2-64 years). Side effects of the renal biopsies included pain at the site of biopsy in 2 (2.7%), gross hematuria in 1 (0.9%). Nephrotic syndrome was the most common indication for biopsy followed by acute renal failure of unknown etiology and nephritic syndrome. Primary glomerular disease was reported in 78 patients (70.2%) and also secondary glomerular disease in 33 patients (29.7%). Among the primary glomerulonephritis disease, minimal change disease and membranous glomerulonephritis were the commonest findings in children below the age of 16 years. Minimal change disease ranked first in adults whole membranous glomerular disease and focal segmental glomerulosclerosis were more common in the elderly. In all patients lupus glomerular disease was the commonest secondary glomerular disease. We conclude that study on renal biopsy makes final diagnosis which is associated with an acceptably low rate of complications in our practice, and in all, the patterns of renal histology in our study vary slightly from those reported from other countries. PMID:20368927

  13. Bone biopsy in the diagnosis of renal osteodystrophy.

    PubMed

    Spasovski, Goce B

    2004-01-01

    When renal disease develops, mineral and vitamin D homeostasis is disrupted, resulting in diverse manifestations in bone cells and structure as well as the rate of bone turnover. In ESRF when patients require chronic maintenance dialysis, nearly all of them have abnormal bone histology named renal osteodystrophy (ROD). On the other hand, survival rates of patients on dialysis have increased with improved dialytic therapy and the resultant increased duration of dialysis has led to a rise in renal osteodystrophy. Because this metabolic bone disease can produce fractures, bone pain, and deformities late in the course of the disease, prevention and early treatment are essential. Serum PTH levels are commonly used to assess bone turnover in dialyzed patients. However, it is found that serum PTH levels between 65 and 450 pg/ml seen in the majority of dialysis patients are not predictive of the underlying bone disease. To date, bone biopsy is the most powerful and informative diagnostic tool to provide important information on precisely the type of renal osteodystrophy affecting patients, the degree of severity of the lesions, and the presence and amount of aluminum and strontium deposition in bone. Bone biopsy is not only useful in clinical settings but also in research to assess the effects of therapies on bone. Although considered as an invasive procedure, bone biopsy has been proven as safe and free from major complications besides pain, haematoma or wound infections, but the operator's experience and skill is important in minimizing morbidity. Alternatives to bone biopsy continue to be pursued, but the non-invasive bone markers have not been proven to hold sufficient diagnostic performance related to the bone turnover, mineralization process and bone cell abnormality. At present however, the transiliac bone biopsy remains the golden standard in the diagnosis of renal osteodystrophy. PMID:15735537

  14. Mechanically assisted 3D ultrasound guided prostate biopsy system.

    PubMed

    Bax, Jeffrey; Cool, Derek; Gardi, Lori; Knight, Kerry; Smith, David; Montreuil, Jacques; Sherebrin, Shi; Romagnoli, Cesare; Fenster, Aaron

    2008-12-01

    There are currently limitations associated with the prostate biopsy procedure, which is the most commonly used method for a definitive diagnosis of prostate cancer. With the use of two-dimensional (2D) transrectal ultrasound (TRUS) for needle-guidance in this procedure, the physician has restricted anatomical reference points for guiding the needle to target sites. Further, any motion of the physician's hand during the procedure may cause the prostate to move or deform to a prohibitive extent. These variations make it difficult to establish a consistent reference frame for guiding a needle. We have developed a 3D navigation system for prostate biopsy, which addresses these shortcomings. This system is composed of a 3D US imaging subsystem and a passive mechanical arm to minimize prostate motion. To validate our prototype, a series of experiments were performed on prostate phantoms. The 3D scan of the string phantom produced minimal geometric distortions, and the geometric error of the 3D imaging subsystem was 0.37 mm. The accuracy of 3D prostate segmentation was determined by comparing the known volume in a certified phantom to a reconstructed volume generated by our system and was shown to estimate the volume with less then 5% error. Biopsy needle guidance accuracy tests in agar prostate phantoms showed that the mean error was 2.1 mm and the 3D location of the biopsy core was recorded with a mean error of 1.8 mm. In this paper, we describe the mechanical design and validation of the prototype system using an in vitro prostate phantom. Preliminary results from an ongoing clinical trial show that prostate motion is small with an in-plane displacement of less than 1 mm during the biopsy procedure.

  15. Interventional Optical Molecular Imaging Guidance during Percutaneous Biopsy

    PubMed Central

    Sheth, Rahul A.; Heidari, Pedram; Esfahani, Shadi A.; Wood, Bradford J.

    2014-01-01

    Purpose To investigate indocyanine green (ICG) as a molecular beacon for malignant lesions within the liver and evaluate the ability of a developed handheld imaging system to allow measurement of ICG fluorescence within focal hepatic lesions with high target-to-background ratios in a mouse model. Materials and Methods All animal experiments were approved by the institutional animal care committee. A handheld optical molecular imaging device was constructed to pass through the introducer needle of a standard percutaneous biopsy kit. An ex vivo phantom system was constructed to quantify tissue attenuation properties of ICG in liver parenchyma. Subsequently, intrahepatic colorectal cancer metastases were generated in nude mice, and epifluorescence imaging of ICG, as well as histologic analysis of the explanted livers, was performed at 3 weeks after implantation (n = 6). Epifluorescence imaging with the handheld imaging device was then performed on intrahepatic colorectal metastases after the administration of ICG (n = 15) at 3, 6, and 24 hours after injection. Target-to-background ratios were calculated for each time point. Subsequently, a core biopsy of intrahepatic colorectal metastases was performed by using a standard clinical 18-gauge biopsy needle. Results There was avid localization of ICG to the focal lesions at all time points. Similarly, fluorescence within the tumors was greater than that within normal liver, as detected with the handheld imaging system (mean target-to-background ratio ± standard deviation, 3.9 ± 0.2 at 24 hours). A core biopsy of tumor and normal adjacent liver by using a standard biopsy needle demonstrated a sharp margin of fluorescence intensity at the tumor-liver interface. Conclusion The custom-designed molecular imaging device, in combination with ICG, readily allowed differentiation between normal and malignant tissue in a murine model of intrahepatic colorectal metastasis. © RSNA, 2014 PMID:24520946

  16. Variation in the Attitudes of Medical Oncologists Toward Research Biopsies in Patients With Metastatic Breast Cancer

    PubMed Central

    Seah, Davinia S.; Scott, Sarah; Guo, Hao; Najita, Julie; Lederman, Ruth; Frank, Elizabeth; Sohl, Jessica; Stadler, Zsofia; Silverman, Stuart; Peppercorn, Jeffrey; Winer, Eric; Come, Steve

    2015-01-01

    Background. Tissue from research biopsies provides access to insights into tumor biology. We aimed to determine medical oncologists’ (MOs’) attitudes toward research biopsies in patients with metastatic breast cancer (MBC). Materials and Methods. A total of 309 breast MOs from National Cancer Institute (NCI)-designated cancer centers were invited to complete a self-administered survey about their attitudes toward approaching patients for research purpose-only biopsies (RPOBs), performed as a standalone procedure, or additional biopsies, performed with a clinically indicated biopsy. The MOs were asked to predict what proportion of their MBC patients would consider undergoing research biopsies. Results. Of the 309 MOs, 221 (72%) responded. Of these 221 MOs, 30 were ineligible, leaving 191 eligible responders. Nearly all the MOs reported they were comfortable approaching patients regarding research biopsies of blood or skin. One fifth of MOs were uncomfortable approaching patients for RPOBs of the breast. One half of MOs were uncomfortable approaching patients for RPOBs of the liver. A significant variation was found in the perceptions by MOs of their patients’ willingness to undergo research biopsies. The factors associated with increased comfort in approaching patients for research biopsies included fewer years in practice, caring for patients who had undergone recent research biopsies, and the predicted willingness of patients to consent to biopsies. The risk of a biopsy and biopsy-related pain were the most common reasons for reluctance to refer patients for research biopsies. Conclusion. Significant variation exists, even at NCI centers, in the comfort level of MOs in approaching MBC patients for research biopsies. MOs’ attitudes toward research biopsies might be a modifiable factor in increasing tissue collection for research. Implications for Practice: Tissue-based research is critical in advancing our understanding of cancer biology, and obtaining

  17. Serum testosterone as a biomarker for second prostatic biopsy in men with negative first biopsy for prostatic cancer and PSA>4ng/mL, or with PIN biopsy result

    PubMed Central

    Fiamegos, Alexandros; Varkarakis, John; Kontraros, Michael; Karagiannis, Andreas; Chrisofos, Michael; Barbalias, Dimitrios; Deliveliotis, Charalampos

    2016-01-01

    Abstract Introduction: Data from animal, clinical and prevention studies support the role of androgens in prostate cancer growth, proliferation and progression. Results of serum based epidemiologic studies in humans, however, have been inconclusive. The present study aims to define whether serum testosterone can be used as a predictor of a positive second biopsy in males considered for re-biopsy. Material and Methods: The study included 320 men who underwent a prostatic biopsy in our department from October 2011 until June 2012. Total testosterone, free testosterone, bioavailable testosterone and prostate pathology were evaluated in all cases. Patients undergoing a second biopsy were identified and biopsy results were statistically analyzed. Results: Forty men (12.5%) were assessed with a second biopsy. The diagnosis of the second biopsy was High Grade Intraepithelial Neoplasia in 14 patients (35%) and Prostate Cancer in 12 patients (30%). The comparison of prostatic volume, total testosterone, sex hormone binding globulin, free testosterone, bioavailable testosterone and albumin showed that patients with cancer of the prostate had significantly greater levels of free testosterone (p=0.043) and bioavailable T (p=0.049). Conclusion: In our study, higher free testosterone and bioavailable testosterone levels were associated with a cancer diagnosis at re-biopsy. Our results indicate a possible role for free and bioavailable testosterone in predicting the presence of prostate cancer in patients considered for re-biopsy. PMID:27532110

  18. Polyneuropathy due to acute arsenic intoxication: biopsy studies.

    PubMed

    Goebel, H H; Schmidt, P F; Bohl, J; Tettenborn, B; Krämer, G; Gutmann, L

    1990-03-01

    A 41-year-old vintner attempting suicide ingested 8-9 g of arsenic and developed a symmetric polyneuropathy with acute Wallerian degeneration of myelinated fibers. Under treatment with modified British Anti-Lewisite (BAL; "Dimaval") his polyneuropathy slowly, but incompletely, subsided over three years at which time another sural nerve biopsy specimen showed regenerative proliferation of myelinated and unmyelinated axons but no signs of Wallerian degeneration. By laser microprobe mass analysis (LAMMA) arsenic was located in the first biopsied sural nerve specimen but not in the second specimen. These findings demonstrated: 1) arsenic induced serial morphometric and electron microscopic findings of nerve fiber degeneration and regeneration, 2) documentation of arsenic within myelinated nerve fibers, and 3) the usefulness of the LAMMA technique as a diagnostic procedure in this context.

  19. Atrial fibrillation and pneumothorax after transthoracic needle lung biopsy

    PubMed Central

    Liu, Alexander; Southern, Iain; Nicol, Edward

    2012-01-01

    An obese 65-year-old male smoker with chronic obstructive pulmonary disease developed an iatrogenic pneumothorax with pulmonary haemorrhage during an elective transthoracic needle biopsy of a pulmonary lesion. Successful re-inflation was achieved with a chest drain which was then removed before transfer to the medical ward. He later developed persistent atrial fibrillation with breathlessness and haemoptysis. He was treated empirically for a pulmonary embolus, which was subsequently ruled out with CT pulmonary angiogram. Serial chest radiographs demonstrated recurrence of his pneumothorax and a chest drain was re-inserted. His atrial fibrillation was erroneously managed as supraventricular tachycardia, which was resistant to vagal manoeuvres and adenosine but later responded to intravenous amiodarone before a further relapse. Upon successful management of the pneumothorax, his atrial fibrillation terminated. This case highlighted the persistent and serious nature of complications posttransthoracic needle biopsy. PMID:22665868

  20. Profile of Lesions in Cystoscopic Bladder Biopsies: A Histopathological Study

    PubMed Central

    Srikousthubha; Sukesh; C.V, Raghuveer; Hingle, Sanjay

    2013-01-01

    Aim and Introduction: Urinary bladder lesions, non-neoplastic and neoplastic, are collectively responsible for significant morbidity and mortality throughout the world. The present study aimed to study the histopathology of various lesions of the bladder through cystoscopic biopsies. Material and Methods: The present prospective study aimed to study the histopathology of various lesions of the urinary bladder through cystoscopic biopsies. All patients who visited Urology Outpatients Department for haematuria and dysuria were subjected to cystoscopy. Results: Histopathological examinations revealed an equal share of non neoplastic lesions and neoplastic lesions. Amongst the non neoplastic lesions, 84% were inflammatory lesions. Urothelial tumours (96%) formed the bulk amongst neoplastic lesions. Conclusion: This article has stressed upon the importance of histopathological examinations in evaluating bladder pathologies. PMID:24086853

  1. Early Stage Relapsing Polychondritis Diagnosed by Nasal Septum Biopsy

    PubMed Central

    Kobayashi, Takaaki; Moody, Sandra; Komori, Masafumi; Jibatake, Akira; Yaegashi, Makito

    2015-01-01

    Relapsing polychondritis is a rare inflammation of cartilaginous tissues, the diagnosis of which is usually delayed by a mean period of 2.9 years from symptom onset. We present the case of a 36-year-old man with nasal pain and fever. Physical examination of the nose was grossly unremarkable, but there was significant tenderness of the nasal bridge. Acute sinusitis was initially diagnosed due to thickened left frontal sinus mucosa on computed tomography (CT); however, there was no improvement after antibiotic intake. Repeat CT showed edematous inflammation of the nasal septum; biopsy of this site demonstrated erosion and infiltration of lymphocytes, plasma cells, eosinophils, and neutrophils in the hyaline cartilage. Relapsing polychondritis was confirmed by the modified McAdam's criteria and can be diagnosed at an early stage by nasal septum biopsy; it should be considered as a differential diagnosis in patients presenting with nasal symptoms alone or persistent sinus symptoms. PMID:26843866

  2. Tests on reliability of a prostate biopsy telerobotic system.

    PubMed

    Rovetta, A

    1999-01-01

    This paper deals with the development of a robotic (mechanical-electronic) system that operates in the field of surgery, with new sensors and equipment ("Biopsy Program"). The system permits a rapid analysis of the mechanical needle + needle-holder + mechanism system for penetration and aspiration for surgery, for prostate biopsies. These operations benefit from the use of a SR 8438 Sankyo Scara robot; they are also remote-controlled, i.e. via telerobotics. They require accurate positioning in known points of three-dimensional space with a high degree of precision. The safety of the surgical operations is guaranteed by the most complete observance of regulations under European Union Directives and Decrees 626 and 242 of Italian laws. The system proposed represents a big step for the application of industrial solutions, precisely for industrial companies in the medical and surgical field.

  3. Clinical applications of liquid biopsies in gastrointestinal oncology

    PubMed Central

    Zhu, Jason

    2016-01-01

    “Liquid biopsies” are blood based assays used to detect and analyze circulating tumor products, including circulating tumor cells (CTCs), circulating tumor DNA (ctDNA), circulating messenger RNA (mRNA), circulating microRNA (miRNA), circulating exosomes, and tumor educated platelets (TEP). For patients with gastrointestinal (GI) malignancies, blood based biopsies may offer several advantages. First, tumor tissue samples are often challenging to procure, and when obtainable, are often insufficient for genomic profiling. Second, blood based assays offer a real-time overview of the entire tumor burden, and allow anatomically unbiased genomic profiling. Third, given the convenience and relative safety of liquid biopsies, this technology may facilitate identification of genomic alterations that confer sensitivity and resistance to targeted therapeutics. This review will assess the clinical applications of circulating tumor products for patients with GI tumors. PMID:27747082

  4. Stereotactic biopsy of cerebral lesions in acquired immunodeficiency syndrome.

    PubMed

    Davies, M A; Pell, M F; Brew, B J

    1995-01-01

    The efficacy, mortality and morbidity of CT directed stereotactic biopsy of a cerebral lesion in 32 Human Immunodeficiency Virus (HIV) infected patients between July 1991 and June 1994 who had an atypical presentation for toxoplasmosis or who were failing or intolerant of empirical antitoxoplasmosis treatment was evaluated. An histological diagnosis was able to be made in 85%: progressive multifocal leucoencephalopathy (PML) in 13, primary cerebral lymphoma in 10, toxoplasmosis in 3 and HIV encephalitis in one. Non-specific reactive changes or gliosis were seen in 5 patients. There was no mortality, and morbidity occurred in 2 patients: one intraventricular haemorrhage and one transient third nerve palsy. Correct diagnosis made by image-directed stereotactic biopsy of central nervous system (CNS) disease in acquired immunodeficiency syndrome (AIDS) patients may improve outcome, particularly in those diseases where effective treatment strategies already exist and become increasingly available in the future.

  5. Microfluidic Exosome Analysis toward Liquid Biopsy for Cancer.

    PubMed

    He, Mei; Zeng, Yong

    2016-08-01

    Assessment of a tumor's molecular makeup using biofluid samples, known as liquid biopsy, is a prominent research topic in precision medicine for cancer, due to its noninvasive property allowing repeat sampling for monitoring molecular changes of tumors over time. Circulating exosomes recently have been recognized as promising tumor surrogates because they deliver enriched biomarkers, such as proteins, RNAs, and DNA. However, purification and characterization of these exosomes are technically challenging. Microfluidic lab-on-a-chip technology effectively addresses these challenges owing to its inherent advantages in integration and automation of multiple functional modules, enhancing sensing performance, and expediting analysis processes. In this article, we review the state-of-the-art development of microfluidic technologies for exosome isolation and molecular characterization with emphasis on their applications toward liquid biopsy-based analysis of cancer. Finally, we share our perspectives on current challenges and future directions of microfluidic exosome analysis. PMID:27215792

  6. Robotically assisted small animal MRI-guided mouse biopsy

    NASA Astrophysics Data System (ADS)

    Wilson, Emmanuel; Chiodo, Chris; Wong, Kenneth H.; Fricke, Stanley; Jung, Mira; Cleary, Kevin

    2010-02-01

    Small mammals, namely mice and rats, play an important role in biomedical research. Imaging, in conjunction with accurate therapeutic agent delivery, has tremendous value in small animal research since it enables serial, non-destructive testing of animals and facilitates the study of biomarkers of disease progression. The small size of organs in mice lends some difficulty to accurate biopsies and therapeutic agent delivery. Image guidance with the use of robotic devices should enable more accurate and repeatable targeting for biopsies and delivery of therapeutic agents, as well as the ability to acquire tissue from a pre-specified location based on image anatomy. This paper presents our work in integrating a robotic needle guide device, specialized stereotaxic mouse holder, and magnetic resonance imaging, with a long-term goal of performing accurate and repeatable targeting in anesthetized mice studies.

  7. Fine needle aspiration biopsy diagnosis of mucoepidermoid carcinoma. Statistical analysis.

    PubMed

    Cohen, M B; Fisher, P E; Holly, E A; Ljung, B M; Löwhagen, T; Bottles, K

    1990-01-01

    Fine needle aspiration (FNA) biopsy is an increasingly popular method for the evaluation of salivary gland tumors. Of the common salivary gland tumors, mucoepidermoid carcinoma is probably the most difficult to diagnose accurately by this means. A series of 96 FNA biopsy specimens of salivary gland masses, including 34 mucoepidermoid carcinomas, 51 other benign and malignant neoplasms, 7 nonneoplastic lesions and 4 normal salivary glands, were analyzed in order to identify the most useful criteria for diagnosing mucoepidermoid carcinoma. Thirteen cytologic criteria were evaluated in the FNA specimens, and a stepwise logistic regression analysis was performed. The three cytologic features selected as most predictive of mucoepidermoid carcinoma were intermediate cells, squamous cells and overlapping epithelial groups. Using these three features together, the sensitivity and specificity of accurately diagnosing mucoepidermoid carcinoma were 97% and 100%, respectively.

  8. Fine needle aspiration biopsy cytology of major salivary glands.

    PubMed

    Qizilbash, A H; Sianos, J; Young, J E; Archibald, S D

    1985-01-01

    Fine needle aspiration biopsy of the major salivary glands was performed on 160 patients. In 146 patients with satisfactory samples, the cytologic diagnosis was correlated with clinical follow-up and histologic findings. There were 122 benign lesions, including 47 tumors. There were 24 malignant lesions, 10 of which were primary and 14 metastatic. The overall accuracy was 98%. The sensitivity of the technique was 87.5%. There was no false-positive diagnosis. There were three false-negative diagnoses due to sampling errors and inexperience during the initial period of the study. This study documents that needle aspiration biopsy cytology of the salivary glands is accurate, simple, rapid, inexpensive, well tolerated and harmless to the patient.

  9. Major Bleeding after Percutaneous Image-Guided Biopsies: Frequency, Predictors, and Periprocedural Management

    PubMed Central

    Kennedy, Sean A.; Milovanovic, Lazar; Midia, Mehran

    2015-01-01

    Major bleeding remains an uncommon yet potentially devastating complication following percutaneous image-guided biopsy. This article reviews two cases of major bleeding after percutaneous biopsy and discusses the frequency, predictors, and periprocedural management of major postprocedural bleeding. PMID:25762845

  10. Needle biopsy of the liver. A critique of four currently available methods.

    PubMed Central

    Babb, R R; Jackman, R J

    1989-01-01

    There are currently four needle biopsy methods for obtaining tissue from patients with possible diffuse liver disease or cancer. These include percutaneous blind needle biopsy, a visually guided needle biopsy at laparoscopy, guided fine-needle biopsies with ultrasonography or computed tomography, and the transvenous liver biopsy. We and others have found the guided fine-needle biopsy technique to be safe, relatively cheap, and highly accurate in the diagnosis of liver cancer. Blind percutaneous biopsy should be reserved for patients with possible diffuse, noncancerous, liver disease. Guided biopsies at laparoscopy can be done if the other two methods fail to give a tissue diagnosis. The transvenous approach is useful in patients with a coagulation disorder. PMID:2660406

  11. Application of statistical cancer atlas for 3D biopsy

    NASA Astrophysics Data System (ADS)

    Narayanan, Ramkrishnan; Shen, Dinggang; Davatzikos, Christos; Crawford, E. David; Barqawi, Albaha; Werahera, Priya; Kumar, Dinesh; Suri, Jasjit S.

    2008-02-01

    Prostate cancer is the most commonly diagnosed cancer in males in the United States and the second leading cause of cancer death. While the exact cause is still under investigation, researchers agree on certain risk factors like age, family history, dietary habits, lifestyle and race. It is also widely accepted that cancer distribution within the prostate is inhomogeneous, i.e. certain regions have a higher likelihood of developing cancer. In this regard extensive work has been done to study the distribution of cancer in order to perform biopsy more effectively. Recently a statistical cancer atlas of the prostate was demonstrated along with an optimal biopsy scheme achieving a high detection rate. In this paper we discuss the complete construction and application of such an atlas that can be used in a clinical setting to effectively target high cancer zones during biopsy. The method consists of integrating intensity statistics in the form of cancer probabilities at every voxel in the image with shape statistics of the prostate in order to quickly warp the atlas onto a subject ultrasound image. While the atlas surface can be registered to a pre-segmented subject prostate surface or instead used to perform segmentation of the capsule via optimization of shape parameters to segment the subject image, the strength of our approach lies in the fast mapping of cancer statistics onto the subject using shape statistics. The shape model was trained from over 38 expert segmented prostate surfaces and the atlas registration accuracy was found to be high suggesting the use of this method to perform biopsy in near real time situations with some optimization.

  12. Solitary fibrous tumour of the prostate identified on needle biopsy.

    PubMed

    Galosi, Andrea B; Mazzucchelli, Roberta; Scarpelli, Marina; Lopez-Beltran, Antonio; Cheng, Liang; Muzzonigro, Giovanni; Montironi, Rodolfo

    2009-09-01

    The clinical and radical prostatectomy features of a case of solitary fibrous tumour (SFT) of the prostate identified on needle biopsy are presented. The main differential diagnoses are discussed. SFTs involving the prostate are relatively uncommon, with only isolated cases reported in the literature. Owing to their relative rarity and lack of long-term follow-up, the clinical behaviour of prostatic SFTs is difficult to predict. Complete resection of the tumour is currently the single main prognostic factor.

  13. Markers of Field Cancerization: Proposed Clinical Applications in Prostate Biopsies

    PubMed Central

    Trujillo, Kristina A.; Jones, Anna C.; Griffith, Jeffrey K.; Bisoffi, Marco

    2012-01-01

    Field cancerization denotes the occurrence of genetic, epigenetic, and biochemical aberrations in structurally intact cells in histologically normal tissues adjacent to cancerous lesions. This paper tabulates markers of prostate field cancerization known to date and discusses their potential clinical value in the analysis of prostate biopsies, including diagnosis, monitoring progression during active surveillance, and assessing efficacy of presurgical neoadjuvant and focal therapeutic interventions. PMID:22666601

  14. Fabry's disease: An ultrastructural study of nerve biopsy

    PubMed Central

    Gayathri, N.; Yasha, T. C.; Kanjalkar, Makarand; Agarwal, Santosh; Sagar, B. K. Chandrashekar; Santosh, Vani; Shankar, S. K.

    2008-01-01

    Fabry's disease, an X linked recessive disorder caused by the deficiency of α-galactosidase A (α-gal A), leads to progressive accumulation of glycosphingolipids. We report this rare disease in a 19-year-old boy who presented with angiokeratomas, paresthesia and corneal opacities, and nerve biopsy revealed by electron microscopy lamellated inclusions in the smooth muscle, perineurial and endothelial cells characteristic of Fabry's disease. PMID:19893666

  15. Gastric ulcer penetrating to liver diagnosed by endoscopic biopsy

    PubMed Central

    Kayacetin, Ertugrul; Kayacetin, Serra

    2004-01-01

    Liver penetration is a rare but serious complication of peptic ulcer disease. Usually the diagnosis is made by operation or autopsy. Clinical and laboratory data were no specific. A 64-year-old man was admitted with upper gastrointestinal bleeding. Hepatic penetration was diagnosed as the cause of bleeding. Endoscopy showed a large gastric ulcer with a pseudotumoral mass protruding from the ulcer bed. Definitive diagnosis was established by endoscopic biopsies of the ulcer base. PMID:15188520

  16. An Observation from Liver Biopsies Two Decades Post-Fontan.

    PubMed

    Evans, William N; Acherman, Ruben J; Reardon, Leigh C; Galindo, Alvaro; Rothman, Abraham; Ciccolo, Michael L; Carrillo, Sergio A; Winn, Brody J; Yumiaco, Noel S; Restrepo, Humberto

    2016-08-01

    This brief report describes an observation from liver biopsy results in nonfailing Fontan patients, currently in their second postoperative decade. In three patients, with either atriopulmonary or atrioventricular connections and functional left ventricles, we found no portal fibrosis. In contrast, we found portal fibrosis in three clinically similar, nonfailing Fontan patients with lateral tunnel connections and functional left ventricles. We recognize the results may be secondary to chance; nevertheless, we speculate about possible relevancy.

  17. Detection of preneoplasia in histologically normal prostate biopsies.

    PubMed

    Slater, M D; Delprado, W J; Murphy, C R; Barden, J A

    2001-01-01

    P2X immunolabeling of prostate detected preneoplastic changes in apparently normal tissue. Labeling occurred in two well-defined stages before the diagnostic histological markers of cancer were visible. As cancer progressed, the location of P2X expression changed from confinement within individual nuclei in the acini (stage 1) to a cytoplasmic punctate label in the acinal epithelium, with an associated removal of nuclear stain (stage 2). Finally, in advanced cases, where clear morphological evidence of cancer was apparent, the P2X label condensed exclusively on the apical epithelium (stage 3). BPH/normal tissue was entirely devoid of P2X label. Biopsy samples (77) were tested in three categories. One group (35) were diagnosed as normal benign prostatic hyperplasia (BPH) on the basis of haematoxylin and eosin (H&E) stain, although underlying disease was suspected. Of these, 14 (40%) were clearly normal and appeared entirely devoid of label, 13 (37%) exhibited the first stage of P2X receptor labeling and the remaining eight (23%) exhibited second stage labeling. The accompanying H&E-stained sections of all these cases had a normal appearance. Low grade cancer biopsy samples with Gleason scores G4-7 (25) all revealed widespread second stage receptor labeling in areas of both normal and cancerous morphology, while 17 high grade cancer biopsy samples (Gleason G8-10) all showed third stage labeling along with some residual second stage labeling. The features of each P2X labeling stage occupied the entire histological area affected, offering more opportunity to diagnose the tissue than was supplied by the more-localised diagnostic features identified by H&E-stain. Besides detecting cases of preneoplasia in biopsies with a normal H&E appearance, this technique was also able to rule out the presence of neoplasia in purely hyperplasic prostates by the absence of any P2X labeling.Prostate Cancer and Prostatic Diseases (2001) 4, 92-96 PMID:12497044

  18. Cardiac toxoplasmosis after heart transplantation diagnosed by endomyocardial biopsy.

    PubMed

    Petty, L A; Qamar, S; Ananthanarayanan, V; Husain, A N; Murks, C; Potter, L; Kim, G; Pursell, K; Fedson, S

    2015-10-01

    We describe a case of cardiac toxoplasmosis diagnosed by routine endomyocardial biopsy in a patient with trimethoprim-sulfamethoxazole (TMP-SMX) intolerance on atovaquone prophylaxis. Data are not available on the efficacy of atovaquone as Toxoplasma gondii prophylaxis after heart transplantation. In heart transplant patients in whom TMP-SMX is not an option, other strategies may be considered, including the addition of pyrimethamine to atovaquone.

  19. Transarterial embolization for serious renal hemorrhage following renal biopsy.

    PubMed

    Zeng, Dan; Liu, Guihua; Sun, Xiangzhou; Zhuang, Wenquan; Zhang, Yuanyuan; Guo, Wenbo; Yang, Jianyong; Chen, Wei

    2013-01-01

    The goal of this study is to evaluate the feasibility and efficacy of percutaneous transarterial embolization for the treatment of serious renal hemorrhage after renal biopsy. Nine patients with renal hemorrhage had frank pain and gross hematuria as main symptoms after renal biopsy. Intrarenal arterial injuries and perinephric hematoma were confirmed by angiography in all cases. The arterial injuries led to two types of renal hemorrhage, Type I: severe renal injure or intrarenal renal artery rupture (n=5), with contrast medium spilling out of the artery and spreading into renal pelvis or kidney capsule in angiography; Type II, pseudo aneurysm or potential risk of intrarenal artery injure (n=4), where contrast medium that spilled out of intraartery was retained in the parenchyma as little spots less than 5 mm in diameter in angiography. Transcatheter superselective intrarenal artery embolization was performed with coils or microcoils (Type I intrarenal artery injure) and polyvinyl alcohol particles (Type II injure). The intrarenal arterial injuries were occluded successfully in all patients. Light or mild back or abdominal pain in the side of the embolized kidney was found in three patients following embolization procedures and disappeared 3 days later. Serum creatinine and perinephric hematoma were stable, and gross hematuresis stopped immediately (n=4) or 3-5 days (n=3) after embolization. In conclusions, transcatheter superselective intrarenal artery embolization as a minimally invasive therapy is safe and effective for treatment of serious renal hemorrhage following percutaneous renal biopsy.

  20. Pancreatic cancer: Are "liquid biopsies" ready for prime-time?

    PubMed

    Lewis, Alexandra R; Valle, Juan W; McNamara, Mairead G

    2016-08-28

    Pancreatic cancer is a disease that carries a poor prognosis. Accurate tissue diagnosis is required. Tumours contain a high content of stromal tissue and therefore biopsies may be inconclusive. Circulating tumour cells (CTCs) have been investigated as a potential "liquid biopsy" in several malignancies and have proven to be of prognostic value in breast, prostate and colorectal cancers. They have been detected in patients with localised and metastatic pancreatic cancer with sensitivities ranging from 38%-100% using a variety of platforms. Circulating tumour DNA (ctDNA) has also been detected in pancreas cancer with a sensitivity ranging from 26%-100% in studies across different platforms and using different genetic markers. However, there is no clear consensus on which platform is the most effective for detection, nor which genetic markers are the most useful to use. Potential roles of liquid biopsies include diagnosis, screening, guiding therapies and prognosis. The presence of CTCs or ctDNA has been shown to be of prognostic value both at diagnosis and after treatment in patients with pancreatic cancer. However, more prospective studies are required before this promising technology is ready for adoption into routine clinical practice. PMID:27621566

  1. Liquid biopsies in lung cancer: the new ambrosia of researchers.

    PubMed

    Rolfo, Christian; Castiglia, Marta; Hong, David; Alessandro, Riccardo; Mertens, Inge; Baggerman, Geert; Zwaenepoel, Karen; Gil-Bazo, Ignacio; Passiglia, Francesco; Carreca, Anna P; Taverna, Simona; Vento, Renza; Santini, Daniele; Peeters, Marc; Russo, Antonio; Pauwels, Patrick

    2014-12-01

    In the last decades the approach to cancer patient management has been deeply revolutionized. We are moving from a "one-fits-all" strategy to the "personalized medicine" based on the molecular characterization of the tumor. In this new era it is becoming more and more clear that the monitoring of the disease is fundamental for the success of the treatment, thus there is the need of new biomarker discovery. More precisely in the last years the scientific community has started to use the term "liquid biopsy". A liquid biopsy is a liquid biomarker that can be easily isolated from many body fluids (blood, saliva, urine, ascites, pleural effusion, etc.) and, as well as a tissue biopsy, a representative of the tissue from which it is spread. In this review we will focus our attention on circulating tumor cells, circulating tumor DNA, exosomes and secretomes with the aim to underlie their usefulness and potential application in a clinical setting for lung cancer patient management. PMID:25444714

  2. Pancreatic cancer: Are "liquid biopsies" ready for prime-time?

    PubMed

    Lewis, Alexandra R; Valle, Juan W; McNamara, Mairead G

    2016-08-28

    Pancreatic cancer is a disease that carries a poor prognosis. Accurate tissue diagnosis is required. Tumours contain a high content of stromal tissue and therefore biopsies may be inconclusive. Circulating tumour cells (CTCs) have been investigated as a potential "liquid biopsy" in several malignancies and have proven to be of prognostic value in breast, prostate and colorectal cancers. They have been detected in patients with localised and metastatic pancreatic cancer with sensitivities ranging from 38%-100% using a variety of platforms. Circulating tumour DNA (ctDNA) has also been detected in pancreas cancer with a sensitivity ranging from 26%-100% in studies across different platforms and using different genetic markers. However, there is no clear consensus on which platform is the most effective for detection, nor which genetic markers are the most useful to use. Potential roles of liquid biopsies include diagnosis, screening, guiding therapies and prognosis. The presence of CTCs or ctDNA has been shown to be of prognostic value both at diagnosis and after treatment in patients with pancreatic cancer. However, more prospective studies are required before this promising technology is ready for adoption into routine clinical practice.

  3. Neoadjuvant Therapy in Rectal Cancer - Biobanking of Preoperative Tumor Biopsies

    PubMed Central

    Jo, Peter; Nietert, Manuel; Gusky, Linda; Kitz, Julia; Conradi, Lena C.; Müller-Dornieden, Annegret; Schüler, Philipp; Wolff, Hendrik A.; Rüschoff, Josef; Ströbel, Philipp; Grade, Marian; Liersch, Torsten; Beißbarth, Tim; Ghadimi, Michael B.; Sax, Ulrich; Gaedcke, Jochen

    2016-01-01

    Translational research relies on high-quality biospecimens. In patients with rectal cancer treated preoperatively with radiochemotherapy tissue based analyses are challenging. To assess quality challenges we analyzed tissue samples taken over the last years in a multicenter setting. We retrospectively evaluated overall 197 patients of the CAO/ARO/AIO-94- and 04-trial with locally advanced rectal cancer that were biopsied preoperatively at the University Medical Center Goettingen as well as in 10 cooperating hospitals in Germany. The cellular content of tumor, mucosa, stroma, necrosis and the amount of isolated DNA and RNA as well as the RNA integrity number (RIN) as quality parameters were evaluated. A high RNA yield (p = 2.75e–07) and the content of tumor (p = 0.004) is significantly associated to high RIN-values, whereas a high content of mucosa (p = 0.07) shows a trend and a high amount of necrosis (p = 0.01) is significantly associated with RNA of poor quality. Correlating biopsies from Goettingen and the cooperating centers showed comparable tumor content results. By taking small sized biopsies we could assess a clear correlation between a good RNA quality and a high amount of RNA and tumor cells. These results also indicate that specimens collected at different centers are of comparable quality. PMID:27752113

  4. [Lung biopsy by thoracotomy. 23 cases (author's transl)].

    PubMed

    Legrand, M; Andreassian, B; Chemouilli, E

    1978-12-30

    This series of surgical lung biopsies performed for diffuse lung disease indicates the excellent tolerance of the procedure and the high diagnostic rate. It is indicated above all in the presence of bilateral reticulo-nodular radiological appearances, suggestive of focal lesions not identified by the usual means. The surgical procedure was felt to be justified on the one hand because of the time gained in reaching a precise diagnosis whilst the results of usual laboratory investigations, even the most sophisticated, remain uncertain, and secondly in view of the discovery by the method of malignant lesions which are still curable and which it would have been impossible to identify otherwise, except by awaiting the development of more accessible lesions. Whilst percutaneous needle biopsy found favour amongst many, it would now seem to have been virtually abandoned, particular in France, in view of its risks and it's poor diagnostic rate. By contrast, open surgical biopsy provides in all cases not only lung but also pleural and mediastinal tissue. Its risks are confined to those of any surgical procedure under general anaesthesia, but appear to be sufficiently slight (mortality of 0,5 to 2%) that the technique may be used successfully in intensive care units to obtain a diagnosis in cases of certain types of respiratory distress. PMID:311466

  5. Immunohistochemical Characterization of Facioscapulohumeral Muscular Dystrophy Muscle Biopsies

    PubMed Central

    Statland, Jeffrey M; Odrzywolski, Karen J; Shah, Bharati; Henderson, Don; Fricke, Alex F.; van der Maarel, Silvère M; Tapscott, Stephen J; Tawil, Rabi

    2015-01-01

    Background Posited pathological mechanisms in Facioscapulohumeral Muscular Dystrophy (FSHD) include activation in somatic tissue of normally silenced genes, increased susceptibility to oxidative stress, and induction of apoptosis. Objective To determine the histopathological changes in FSHD muscle biopsies and compare to possible pathological mechanisms of disease. Methods We performed a cross-sectional study on quadriceps muscle biopsies from 32 genetically confirmed FSHD participants, compared to healthy volunteers and myotonic dystrophy type 1 as disease controls. Biopsies were divided into groups to evaluate apoptosis rates, capillary density, myonuclear and satellite cell counts. Results Apoptosis rates were increased in FSHD (n=10, 0.74%) compared to myotonic dystrophy type 1 (n=10, 0.14%, P=0.003) and healthy volunteers (n=14, 0.13%, P=0.002). Apoptosis was higher in FSHD patients with the smallest residual D4Z4 fragments. Capillary density was decreased in FSHD1 (n=10, 316 capillaries/mm2) compared to healthy volunteers (n=15, 448 capillaries/mm2, P=0.001). No differences were seen in myonuclear or satellite cell counts. Conclusions Preliminary evidence for increased apoptosis rates and reduced capillary density may reflect histopathological correlates of disease activity in FSHD. The molecular-pathological correlates to these changes warrants further investigation. PMID:26345300

  6. Core needle biopsy guidance based on EMOCT imaging (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Iftimia, Nicusor V.; Park, Jesung; Maguluri, Gopi

    2016-03-01

    We present a novel method, based on encoder mapping OCT imaging, for real-time guidance of core biopsy procedures. This method provides real-time feedback to the interventional radiologist, such that he/she can reorient the needle during the biopsy and sample the most representative area of the suspicious mass that is being investigated. This aspect is very important for tailoring therapy to the specific cancer based on biomarker analysis, which will become one of the next big advances in our search for the optimal cancer therapy. To enable individualized treatment, the genetic constitution and the DNA repair status in the affected areas is needed for each patient. Thus, representative sampling of the tumor is needed for analyzing various biomarkers, which are used as a tool to personalize cancer therapy. The encoder-based OCT enables samping of large size masses and provides full control on the imaging probe, which is passed through the bore of the biopsy guidance needle. The OCT image is built gradually, based on the feedback of an optical encoder which senses the incremental movement of the needle with a few microns resolution. Tissue mapping is independent of the needle speed, while it is advanced through the tissue. The OCT frame is analyzed in real-time and tissue cellularity is reported in a very simple manner (pie chart). Our preliminary study on a rabbit model of cancer has demonstrated the capability of this technology for accurately differentiating between viable cancer and heterogeneous or necrotic tissue.

  7. Optical biopsy mapping for minimally invasive cancer screening.

    PubMed

    Mountney, Peter; Giannarou, Stamatia; Elson, Daniel; Yang, Guang-Zhong

    2009-01-01

    The quest for providing tissue characterization and functional mapping during minimally invasive surgery (MIS) has motivated the development of new surgical tools that extend the current functional capabilities of MIS. Miniaturized optical probes can be inserted into the instrument channel of standard endoscopes to reveal tissue cellular and subcellular microstructures, allowing excision-free optical biopsy. One of the limitations of such a point based imaging and tissue characterization technique is the difficulty of tracking probed sites in vivo. This prohibits large area surveillance and integrated functional mapping. The purpose of this paper is to present an image-based tracking framework by combining a semi model-based instrument tracking method with vision-based simultaneous localization and mapping. This allows the mapping of all spatio-temporally tracked biopsy sites, which can then be re-projected back onto the endoscopic video to provide a live augmented view in vivo, thus facilitating re-targeting and serial examination of potential lesions. The proposed method has been validated on phantom data with known ground truth and the accuracy derived demonstrates the strength and clinical value of the technique. The method facilitates a move from the current point based optical biopsy towards large area multi-scale image integration in a routine clinical environment. PMID:20426023

  8. Sentinel node biopsy for ipsilateral breast cancer recurrence: a review.

    PubMed

    Palit, G; Jacquemyn, Y; Tjalma, W

    2008-01-01

    The aim of this study was to review published reports on the feasability, results, and reliability of sentinel node biopsy in cases of ipsilateral recurrent breast cancer. A Medline search on publications from January 1999 to December 2007 and cross-references in published articles were looked for. We identified 16 reports on sentinel node biopsy in recurrent breast cancer, including a total of 287 patients. In 210/287 (73.2%) a sentinel node was identified, 77/210 (37.7%) had had previous axillary lymph node dissection and 131 (62.3%) a previous sentinel node procedure. Aberrant lymphatic drainage, other than the ipsilateral axilla was noted in 68/210 (32.4%). Of these 16/68 (23.6%) were located in the contralateral axilla. Of the removed contralateral axillary sentinel nodes 8/17 (47.1%) were invaded by cancer. We conclude that sentinel node biopsy in cases of recurrent ipsilateral breast cancer is feasible. In about one out of three cases drainage to the contralateral axilla with invasion in almost half the cases takes place. The therapeutical consequences of these findings need further study. PMID:19115679

  9. Application of a New Guiding System in Percutaneous Biopsies

    SciTech Connect

    Petsas, Theodore Tsota, Irene; Kalogeropoulou, Christina P.; Liatsikos, Evangelos N.

    2007-04-15

    We herein describe the application of a new guiding system designed for percutaneous biopsies. The guiding system set is composed of a 0.41 mm (27G) stainless steel guide stylet and a 22G Chiba needle. Following the initial insertion of the Chiba needle, the stylet is advanced via the needle toward the lesion. The stylet serves either as a guide for the Chiba needle or as an exchange wire for the introduction of larger or cutting biopsy needles. The stylet can also be curved prior to its insertion to facilitate access to lesions which require needle redirection. The technique was applied to 117 cases (54 thoracic, 31 abdominal, 21 pelvic, and 11 vertebral lesions.) The main advantage of the stylet is its small diameter, rendering it atraumatic and permitting multiple punctures for the successful final targeting of the lesion. With this guiding set we achieved targeting of difficult lesions. Furthermore, larger needles were more easily introduced in locations that posed technical difficulties. No major complications were observed. The complication rate was comparable to that of the conventional biopsy technique. The technique using the guide stylet was easily performed and could be applied to almost all organs.

  10. Isobaric (gasless) laparoscopic liver and kidney biopsy in standing steers

    PubMed Central

    Chiesa, O. Alberto; von Bredow, Jurgen; Li, Hui; Smith, Michelle

    2009-01-01

    The purpose of the current study was to investigate the suitability of an isobaric laparoscopic procedure, using a single port, for obtaining serial kidney and liver biopsy samples from standing steers. The samples were used in support of a pharmacokinetic tissue–fluid correlation study. Laparoscopic access was performed 3 times in each of 8 healthy Holstein steers, alternating from the right side to the left side and then to the right side again. The surgery was performed in standing stocks after the animals were given 3 doses of sulfadimethoxine sulfate intravenously and fasted for at least 18 h. Sedation and analgesia were achieved with acepromazine and xylazine. Lidocaine 2% was injected at the center of the paralumbar fossa (left or right), and an incision was made for introduction of a trocar–cannula assembly. Room air was allowed to enter the abdomen through the cannula at the time of insertion. Once the peritoneal cavity was reached, an operating endoscope was inserted. No pressurized insufflation was performed. A biopsy forceps was introduced into the operating channel of the endoscope to obtain a 100-mg kidney or liver sample. No complications were encountered. The 24 laparoscopic procedures provided 24 kidney and 16 liver samples. The results suggest that the isobaric (gasless) single-port laparoscopic technique is feasible for kidney and liver biopsy on standing steers. The procedure can be performed in a reliable and efficient manner in the sedated standing bovine. PMID:19337395

  11. Transjugular renal biopsy in a case of nephrotic syndrome with extrahepatic portal venous obstruction.

    PubMed

    Siddiqi, N; Someshwar, V; Roy, D; Anandh, U

    2013-03-01

    Renal biopsy in patients with nephrotic syndrome helps to establish the pathological diagnosis and subsequent treatment. In certain circumstances, biopsies are difficult to obtain because of the risk of bleeding. We report a case where renal biopsy was obtained through the transjugular route in a patient who had nephrotic syndrome with extrahepatic portal venous obstruction.

  12. Core needle biopsy versus fine needle aspiration biopsy in breast--a historical perspective and opportunities in the modern era.

    PubMed

    Nassar, Aziza

    2011-05-01

    Breast fine-needle aspiration biopsy (FNAB) by palpation is on the decline, due to its limitations in diagnostic accuracy, decreased sensitivity, and its replacement with core needle biopsy (CNB). Despite its decreasing utility, superficial fine-needle aspiration (FNA) in breast is still the main modality for evaluating metastatic lesions, recurrence, and axillary lymph node metastasis. New modalities including proteomic pattern expression and methylation profiling of breast lesions are other promising techniques that can be used as ancillary tests for refining the diagnosis of breast lesions using FNAB. Image-guided breast FNA proves to be a successful alternative with high sensitivity and specificity. In this review, the advantages, disadvantages, and inherent limitations of breast FNA and CNB, and new advanced techniques are discussed.

  13. Electromyography (EMG) accuracy compared to muscle biopsy in childhood.

    PubMed

    Rabie, Malcolm; Jossiphov, Joseph; Nevo, Yoram

    2007-07-01

    Reports show wide variability of electromyography (EMG) in detecting pediatric neuromuscular disorders. The study's aim was to determine EMG/nerve conduction study accuracy compared to muscle biopsy and final clinical diagnosis, and sensitivity for myopathic motor unit potential detection in childhood. Of 550 EMG/nerve conduction studies performed by the same examiner from a pediatric neuromuscular service, 27 children (ages 6 days to 16 years [10 boys; M:F, 1:1.7]) with muscle biopsies and final clinical diagnoses were compared retrospectively. Final clinical diagnoses were congenital myopathies (5 of 27,18%), nonspecific myopathies (biopsy myopathic, final diagnosis uncertain; 6 of 27, 22%), congenital myasthenic syndrome (3 of 27, 11%), juvenile myasthenia gravis (1 of 27, 4%), arthrogryposis multiplex congenita (2 of 27, 7%), hereditary motor and sensory neuropathy (1 of 27, 4%), bilateral peroneal neuropathies (1 of 27, 4%), and normal (8 of 27, 30%). There were no muscular dystrophy or spinal muscular atrophy patients. EMG/nerve conduction studies had a 74% agreement with final clinical diagnoses and 100% agreement in neurogenic, neuromuscular junction, and normal categories. Muscle biopsies concurred with final diagnoses in 87%, and 100% in myopathic and normal categories. In congenital myasthenic syndrome, muscle biopsies showed mild variation in fiber size in 2 of 3 children and were normal in 1 of 3. EMG sensitivity for detecting myopathic motor unit potentials in myopathies was 4 of 11 (36%), greater over 2 years of age (3 of 4, 75%), compared to infants less than 2 years (1 of 7, 14%), not statistically significant (P = .0879). EMGs false-negative for myopathy in infants < 2 years of age were frequently neurogenic (3 of 6, 50%). In congenital myopathies EMG detected myopathic motor unit potentials in 40%, with false-negative results neurogenic (20%) or normal (40%). Because our study has no additional tests for active myopathies, for example Duchenne

  14. Electromagnetic-Tracked Biopsy under Ultrasound Guidance: Preliminary Results

    SciTech Connect

    Hakime, Antoine Deschamps, Frederic; Marques De Carvalho, Enio Garcia; Barah, Ali; Auperin, Anne; Baere, Thierry De

    2012-08-15

    Purpose: This study was designed to evaluate the accuracy and safety of electromagnetic needle tracking for sonographically guided percutaneous liver biopsies. Methods: We performed 23 consecutive ultrasound-guided liver biopsies for liver nodules with an electromagnetic tracking of the needle. A sensor placed at the tip of a sterile stylet (18G) inserted in a coaxial guiding trocar (16G) used for biopsy was localized in real time relative to the ultrasound imaging plane, thanks to an electromagnetic transmitter and two sensors on the ultrasound probe. This allows for electronic display of the needle tip location and the future needle path overlaid on the real-time ultrasound image. Distance between needle tip position and its electronic display, number of needle punctures, number of needle pull backs for redirection, technical success (needle positioned in the target), diagnostic success (correct histopathology result), procedure time, and complication were evaluated according to lesion sizes, depth and location, operator experience, and 'in-plane' or 'out-of-plane' needle approach. Results: Electronic display was always within 2 mm from the real position of the needle tip. The technical success rate was 100%. A single needle puncture without repuncture was used in all patients. Pull backs were necessary in six patients (26%) to obtain correct needle placement. The overall diagnostic success rate was 91%. The overall true-positive, true-negative, false-negative, and failure rates of the biopsy were 100% (19/19) 100% (2/2), 0% (0/23), and 9% (2/23). The median total procedure time from the skin puncture to the needle in the target was 30 sec (from 5-60 s). Lesion depth and localizations, operator experience, in-plane or out-of-plane approach did not affect significantly the technical, diagnostic success, or procedure time. Even when the tumor size decreased, the procedure time did not increase. Conclusions: Electromagnetic-tracked biopsy is accurate to determine

  15. Realtime TRUS/MRI Fusion Targeted-Biopsy for Prostate Cancer: A Clinical Demonstration of Increased Positive Biopsy Rates

    NASA Astrophysics Data System (ADS)

    Kadoury, Samuel; Yan, Pingkun; Xu, Sheng; Glossop, Neil; Choyke, Peter; Turkbey, Baris; Pinto, Peter; Wood, Bradford J.; Kruecker, Jochen

    In this paper, a system for fusion of realtime transrectal ultrasound (TRUS) with pre-acquired 3D images of the prostate is presented with a clinical demonstration on a cohort of 101 patients with suspicion of prostate cancer. Electromagnetically tracked biopsy guides for endocavity ultrasound transducers were calibrated and used to fuse MRI-based suspicious lesion locations with ultrasound image coordinates. The prostate shape is segmented from MRI in a semi-automated fashion via a model-based approach, and intraoperative image registration is performed between MR and ultrasound image space to superimpose target fiducials markers on the ultrasound image. In order to align both modalities, a surface model is automatically extracted from 2D swept TRUS images using a partial active shape model, utilizing image features and prior statistics. An automatic prostate motion compensation algorithm can be triggered as needed. The results were used to display live TRUS images fused with spatially corresponding realtime multiplanar reconstructions (MPRs) of the MR image volume. In this study, all patients were scanned with 3T MRI and TRUS for biopsy. Clinical results show significant improvement of target visualization and of positive detection rates during TRUS-guided biopsies. It also demonstrates the feasibility of realtime MR/TRUS image fusion for out-of-gantry procedures.

  16. Cancer detection rates of different prostate biopsy regimens in patients with renal failure.

    PubMed

    Hoşcan, Mustafa Burak; Özorak, Alper; Oksay, Taylan; Perk, Hakkı; Armağan, Abdullah; Soyupek, Sedat; Serel, Tekin Ahmet; Koşar, Alim

    2014-07-01

    We aimed to evaluate the cancer detection rates of 6-, 10-, 12-core biopsy regimens and the optimal biopsy protocol for prostate cancer diagnosis in patients with renal failure. A total of 122 consecutive patients with renal failure underwent biopsy with age-specific prostate-specific antigen (PSA) levels up to 20 ng/mL. The 12-core biopsy technique (sextant biopsy + lateral base, lateral mid-zone, lateral apex, bilaterally) performed to all patients. Pathology results were examined separately for each sextant, 10-core that exclude parasagittal mid-zones from 12-cores (10a), 10-core that exclude apex zones from 12-cores (10b) and 12-core biopsy regimens. Of 122 patients, 37 (30.3%) were positive for prostate cancer. The cancer detection rates for sextant, 10a, 10b and 12 cores were 17.2%, 29%, 23.7% and 30.7%, respectively. Biopsy techniques of 10a, 10b and 12 cores increased the cancer detection rates by 40%, 27.5% and 43.2% among the sextant technique, respectively. Biopsy techniques of 10a and 12 cores increased the cancer detection rates by 17.1% and 21.6% among 10b biopsy technique, respectively. There were no statistical differences between 12 core and 10a core about cancer detection rate. Adding lateral cores to sextant biopsy improves the cancer detection rates. In our study, 12-core biopsy technique increases the cancer detection rate by 5.4% among 10a core but that was not statistically different. On the other hand, 12-core biopsy technique includes all biopsy regimens. We therefore suggest 12-core biopsy or minimum 10-core strategy incorporating six peripheral biopsies with elevated age- specific PSA levels up to 20 ng/mL in patients with renal failure. PMID:24797801

  17. How to Interpret Thyroid Biopsy Results: A Three-Year Retrospective Interventional Radiology Experience

    SciTech Connect

    Oppenheimer, Jason D. Kasuganti, Deepa; Nayar, Ritu; Chrisman, Howard B.; Lewandowski, Robert J.; Nemcek, Albert A.; Ryu, Robert K.

    2010-08-15

    Results of thyroid biopsy determine whether thyroid nodule resection is appropriate and the extent of thyroid surgery. At our institution we use 20/22-gauge core biopsy (CBx) in conjunction with fine-needle aspiration (FNA) to decrease the number of passes and improve adequacy. Occasionally, both ultrasound (US)-guided FNA and CBx yield unsatisfactory specimens. To justify clinical recommendations for these unsatisfactory thyroid biopsies, we compare rates of malignancy at surgical resection for unsatisfactory biopsy results against definitive biopsy results. We retrospectively reviewed a database of 1979 patients who had a total of 2677 FNA and 663 CBx performed by experienced interventional radiologists under US guidance from 2003 to 2006 at a tertiary-care academic center. In 451 patients who had surgery following biopsy, Fisher's exact test was used to compare surgical malignancy rates between unsatisfactory and malignant biopsy cohorts as well as between unsatisfactory and benign biopsy cohorts. We defined statistical significance at P = 0.05. We reported an overall unsatisfactory thyroid biopsy rate of 3.7% (100/2677). A statistically significant higher rate of surgically proven malignancies was found in malignant biopsy patients compared to unsatisfactory biopsy patients (P = 0.0001). The incidence of surgically proven malignancy in unsatisfactory biopsy patients was not significantly different from that in benign biopsy patients (P = 0.8625). In conclusion, an extremely low incidence of malignancy was associated with both benign and unsatisfactory thyroid biopsy results. The difference in incidence between these two groups was not statistically significant. Therefore, patients with unsatisfactory biopsy specimens can be reassured and counseled accordingly.

  18. Cancer detection rates of different prostate biopsy regimens in patients with renal failure.

    PubMed

    Hoşcan, Mustafa Burak; Özorak, Alper; Oksay, Taylan; Perk, Hakkı; Armağan, Abdullah; Soyupek, Sedat; Serel, Tekin Ahmet; Koşar, Alim

    2014-07-01

    We aimed to evaluate the cancer detection rates of 6-, 10-, 12-core biopsy regimens and the optimal biopsy protocol for prostate cancer diagnosis in patients with renal failure. A total of 122 consecutive patients with renal failure underwent biopsy with age-specific prostate-specific antigen (PSA) levels up to 20 ng/mL. The 12-core biopsy technique (sextant biopsy + lateral base, lateral mid-zone, lateral apex, bilaterally) performed to all patients. Pathology results were examined separately for each sextant, 10-core that exclude parasagittal mid-zones from 12-cores (10a), 10-core that exclude apex zones from 12-cores (10b) and 12-core biopsy regimens. Of 122 patients, 37 (30.3%) were positive for prostate cancer. The cancer detection rates for sextant, 10a, 10b and 12 cores were 17.2%, 29%, 23.7% and 30.7%, respectively. Biopsy techniques of 10a, 10b and 12 cores increased the cancer detection rates by 40%, 27.5% and 43.2% among the sextant technique, respectively. Biopsy techniques of 10a and 12 cores increased the cancer detection rates by 17.1% and 21.6% among 10b biopsy technique, respectively. There were no statistical differences between 12 core and 10a core about cancer detection rate. Adding lateral cores to sextant biopsy improves the cancer detection rates. In our study, 12-core biopsy technique increases the cancer detection rate by 5.4% among 10a core but that was not statistically different. On the other hand, 12-core biopsy technique includes all biopsy regimens. We therefore suggest 12-core biopsy or minimum 10-core strategy incorporating six peripheral biopsies with elevated age- specific PSA levels up to 20 ng/mL in patients with renal failure.

  19. Comparison of flexible fiberoptic bronchoscopy and scalene lymph node biopsy in the diagnosis of sarcoidosis.

    PubMed

    Stjernberg, N; Thunell, M; Lundgren, R

    1983-09-01

    The diagnostic accuracy achieved by taking bronchial mucosal and lung biopsies through flexible fiberoptic bronchoscopes was compared with scalene lymph node biopsy in 55 patients with sarcoidosis. The diagnostic yield with flexible fiberoptic bronchoscopy was 62 per cent in the whole material and increased to 76 per cent in patients with stage II sarcoidosis. Scalene lymph node biopsy was positive in 80 per cent. Flexible fiberoptic bronchoscopy is a useful method for obtaining biopsy material in sarcoidosis, especially in stage II sarcoidosis. We consider flexible fiberoptic bronchoscopy and scalene lymph node biopsy the methods of choice in the diagnosis of sarcoidosis. PMID:6628338

  20. Multiparametric MRI and targeted prostate biopsy: Improvements in cancer detection, localization, and risk assessment

    PubMed Central

    Bjurlin, Marc A.; Mendhiratta, Neil; Wysock, James S.

    2016-01-01

    Introduction Multiparametric-MRI (mp-MRI) is an evolving noninvasive imaging modality that increases the accurate localization of prostate cancer at the time of MRI targeted biopsy, thereby enhancing clinical risk assessment, and improving the ability to appropriately counsel patients regarding therapy. Material and methods We used MEDLINE/PubMed to conduct a comprehensive search of the English medical literature. Articles were reviewed, data was extracted, analyzed, and summarized. In this review, we discuss the mp-MRI prostate exam, its role in targeted prostate biopsy, along with clinical applications and outcomes of MRI targeted biopsies. Results Mp-MRI, consisting of T2-weighted imaging, diffusion-weighted imaging, dynamic contrast-enhanced imaging, and possibly MR spectroscopy, has demonstrated improved specificity in prostate cancer detection as compared to conventional T2-weighted images alone. An MRI suspicion score has been developed and is depicted using an institutional Likert or, more recently, a standardized reporting scale (PI-RADS). Techniques of MRI-targeted biopsy include in-gantry MRI guided biopsy, TRUS-guided visual estimation biopsy, and software co-registered MRI-US guided biopsy (MRI-US fusion). Among men with no previous biopsy, MRI-US fusion biopsy demonstrates up to a 20% increase in detection of clinically significant cancers compared to systematic biopsy while avoiding a significant portion of low risk disease. These data suggest a potential role in reducing over-detection and, ultimately, over-treatment. Among men with previous negative biopsy, 72–87% of cancers detected by MRI targeted biopsy are clinically significant. Among men with known low risk cancer, repeat biopsy by MR-targeting improves risk stratification in selecting men appropriate for active surveillance secondarily reducing the need for repetitive biopsy during surveillance. Conclusions Use of mp-MRI for targeting prostate biopsies has the potential to reduce the

  1. Adverse Effects of Vapocoolant and Topical Anesthesia for Tail Biopsy of Preweanling Mice

    PubMed Central

    Braden, Gillian C; Brice, Angela K; Hankenson, F Claire

    2015-01-01

    Tail biopsy of laboratory mice for genotyping purposes has been studied extensively to develop refinements for this common procedure. Our prior work assessed tail vertebral development in different mouse strains (age, 3 to 42 d) and analyzed behavior and activity in mice (age, 21 to 45 d) biopsied under isoflurane anesthesia. To assess the effects of biopsy on preweanling mice, we here evaluated BALB/cAnNCrl mice (n = 80; age, 18 to 21 d) that received topical vapocoolant (ethyl chloride), topical anesthetic (Cetacaine), or isoflurane anesthesia before undergoing a 5-mm or sham biopsy. Control mice did not receive any anesthetic intervention. Regardless of the anesthetic used, acute observation scores indicative of distress were increased at 10 min after biopsy, and locomotor activity was decreased, in biopsied compared with control mice. Acute observation scores at 10 min after biopsy were higher in mice that received ethyl chloride compared with isoflurane or no anesthesia. Microscopic analysis revealed that inflammatory changes in the distal tail remained elevated until 7 d after biopsy and were higher in tails exposed to ethyl chloride. Our findings indicate that vapocoolant, topical anesthesia, and inhaled isoflurane do not enhance the wellbeing of preweanling mice undergoing tail biopsy. Due to the lack of appreciable benefits and the presence of notable adverse effects, using vapocoolants or Cetacaine for this tail biopsy procedure in laboratory mice is unadvisable and we encourage the removal of these agents from institutional tail biopsy guidelines. PMID:26045455

  2. Adverse effects of vapocoolant and topical anesthesia for tail biopsy of preweanling mice.

    PubMed

    Braden, Gillian C; Brice, Angela K; Hankenson, F Claire

    2015-05-01

    Tail biopsy of laboratory mice for genotyping purposes has been studied extensively to develop refinements for this common procedure. Our prior work assessed tail vertebral development in different mouse strains (age, 3 to 42 d) and analyzed behavior and activity in mice (age, 21 to 45 d) biopsied under isoflurane anesthesia. To assess the effects of biopsy on preweanling mice, we here evaluated BALB/cAnNCrl mice (n = 80; age, 18 to 21 d) that received topical vapocoolant (ethyl chloride), topical anesthetic (Cetacaine), or isoflurane anesthesia before undergoing a 5-mm or sham biopsy. Control mice did not receive any anesthetic intervention. Regardless of the anesthetic used, acute observation scores indicative of distress were increased at 10 min after biopsy, and locomotor activity was decreased, in biopsied compared with control mice. Acute observation scores at 10 min after biopsy were higher in mice that received ethyl chloride compared with isoflurane or no anesthesia. Microscopic analysis revealed that inflammatory changes in the distal tail remained elevated until 7 d after biopsy and were higher in tails exposed to ethyl chloride. Our findings indicate that vapocoolant, topical anesthesia, and inhaled isoflurane do not enhance the wellbeing of preweanling mice undergoing tail biopsy. Due to the lack of appreciable benefits and the presence of notable adverse effects, using vapocoolants or Cetacaine for this tail biopsy procedure in laboratory mice is unadvisable and we encourage the removal of these agents from institutional tail biopsy guidelines.

  3. Evaluation of Common Anesthetic and Analgesic Techniques for Tail Biopsy in Mice

    PubMed Central

    Jones, Carissa P; Carver, Scott; Kendall, Lon V

    2012-01-01

    Tail biopsy in mice is a common procedure in genetically modified mouse colonies. We evaluated the anesthetic and analgesic effects of various agents commonly used to mitigate pain after tail biopsy. We used a hot-water immersion assay to evaluate the analgesic effects of isoflurane, ice-cold ethanol, ethyl chloride, buprenorphine, and 2-point local nerve blocks before studying their effects on mice receiving tail biopsies. Mice treated with ethyl chloride spray, isoflurane and buprenorphine, and 2-point local nerve blocks demonstrated increased tail-flick latency compared with that of untreated mice. When we evaluated the behavior of adult and preweanling mice after tail biopsy, untreated mice demonstrated behavioral changes immediately after tail biopsy that lasted 30 to 60 min before returning to normal. The use of isoflurane, isoflurane and buprenorphine, buprenorphine, 2-point nerve block, or ethyl chloride spray in adult mice did not significantly improve their behavioral response to tail biopsy. Similarly, the use of buprenorphine and ethyl chloride spray in preweanling mice did not improve their behavioral response to tail biopsy compared with that of the untreated group. However, immersion in bupivacaine for 30 s after tail biopsy decreased tail grooming behavior during the first 30 min after tail biopsy. The anesthetic and analgesic regimens tested provide little benefit in adult and preweanling mice. Given that tail biopsy results in pain that lasts 30 to 60 min, investigators should carefully consider the appropriate anesthetic or analgesic regimen to incorporate into tail-biopsy procedures for mice. PMID:23294888

  4. Novel Jumbo Biopsy Forceps for Surveillance of Inflammatory Bowel Disease: A Comparative Retrospective Assessment

    PubMed Central

    Song, Kenneth; Toweill, Daniel; Rulyak, Stephen J.; Lee, Scott D.

    2011-01-01

    Background and Study Aims. Most available jumbo cup forceps require a 3.7 mm biopsy channel, necessitating the use of standard-sized colonoscope. A newer jumbo forceps (Radial Jaw 4 Jumbo Biopsy Forceps [RJ4]) fits within a 3.2 mm biopsy channel, allowing use with a pediatric colonoscope. To assure the RJ4 did not alter biopsy adequacy, we compared the size and quality of specimens to a historical jumbo cup forceps (Radial Jaw 3 Max Capacity Biopsy Forceps, [RJ3 MC]). Patients and Methods. A retrospective comparative study of biopsies taken with either forceps. Biopsies were compared for diameter, depth, crush artifact, and acceptability for diagnosis. Results. 333 specimens were taken with RJ4 and 335 specimens with the RJ3 MC. Mean sample diameter was 4.45 mm and 4.55 mm for the RJ4 and RJ3 MC (P = 0.41). Mean depth of biopsies with the RJ4 was greater (P < 0.01). Conclusions. Biopsies from the RJ4 are similar in size and quality to biopsies from the RJ3 MC. The RJ4 has the advantage of fitting in a smaller biopsy channel. PMID:22007197

  5. Novel jumbo biopsy forceps for surveillance of inflammatory bowel disease: a comparative retrospective assessment.

    PubMed

    Song, Kenneth; Toweill, Daniel; Rulyak, Stephen J; Lee, Scott D

    2011-01-01

    Background and Study Aims. Most available jumbo cup forceps require a 3.7 mm biopsy channel, necessitating the use of standard-sized colonoscope. A newer jumbo forceps (Radial Jaw 4 Jumbo Biopsy Forceps [RJ4]) fits within a 3.2 mm biopsy channel, allowing use with a pediatric colonoscope. To assure the RJ4 did not alter biopsy adequacy, we compared the size and quality of specimens to a historical jumbo cup forceps (Radial Jaw 3 Max Capacity Biopsy Forceps, [RJ3 MC]). Patients and Methods. A retrospective comparative study of biopsies taken with either forceps. Biopsies were compared for diameter, depth, crush artifact, and acceptability for diagnosis. Results. 333 specimens were taken with RJ4 and 335 specimens with the RJ3 MC. Mean sample diameter was 4.45 mm and 4.55 mm for the RJ4 and RJ3 MC (P = 0.41). Mean depth of biopsies with the RJ4 was greater (P < 0.01). Conclusions. Biopsies from the RJ4 are similar in size and quality to biopsies from the RJ3 MC. The RJ4 has the advantage of fitting in a smaller biopsy channel.

  6. Evaluation of common anesthetic and analgesic techniques for tail biopsy in mice.

    PubMed

    Jones, Carissa P; Carver, Scott; Kendall, Lon V

    2012-11-01

    Tail biopsy in mice is a common procedure in genetically modified mouse colonies. We evaluated the anesthetic and analgesic effects of various agents commonly used to mitigate pain after tail biopsy. We used a hot-water immersion assay to evaluate the analgesic effects of isoflurane, ice-cold ethanol, ethyl chloride, buprenorphine, and 2-point local nerve blocks before studying their effects on mice receiving tail biopsies. Mice treated with ethyl chloride spray, isoflurane and buprenorphine, and 2-point local nerve blocks demonstrated increased tail-flick latency compared with that of untreated mice. When we evaluated the behavior of adult and preweanling mice after tail biopsy, untreated mice demonstrated behavioral changes immediately after tail biopsy that lasted 30 to 60 min before returning to normal. The use of isoflurane, isoflurane and buprenorphine, buprenorphine, 2-point nerve block, or ethyl chloride spray in adult mice did not significantly improve their behavioral response to tail biopsy. Similarly, the use of buprenorphine and ethyl chloride spray in preweanling mice did not improve their behavioral response to tail biopsy compared with that of the untreated group. However, immersion in bupivacaine for 30 s after tail biopsy decreased tail grooming behavior during the first 30 min after tail biopsy. The anesthetic and analgesic regimens tested provide little benefit in adult and preweanling mice. Given that tail biopsy results in pain that lasts 30 to 60 min, investigators should carefully consider the appropriate anesthetic or analgesic regimen to incorporate into tail-biopsy procedures for mice.

  7. The value of hysteroscopic biopsy in the diagnosis of endometrial polyps.

    PubMed

    Spadoto-Dias, Daniel; Bueloni-Dias, Flávia Neves; Elias, Leonardo Vieira; Leite, Nilton José; Modotti, Waldir Pereira; Lasmar, Ricardo Bassil; Dias, Rogério

    2016-07-01

    Several studies have demonstrated that the combination of hysteroscopy with endometrial biopsy is more accurate in differentiating endometrial polyps from endometrial hyperplasia and cancer. However, blind biopsy not always confirms hysteroscopic findings due to high rates of inadequate or insufficient material. The objective of this clinical, prospective, and comparative study was to establish a correlation between the histological results of office-based endometrial biopsies (hysteroscopically guided and blind) with the surgical polypectomy specimens. We evaluated 82 patients with hysteroscopic diagnosis of endometrial polyp, who randomly underwent hysteroscopically guided biopsy or blind biopsy, referred for surgical resection. A total of 36 women (43.9%) underwent hysteroscopically guided biopsy and 46 women (56.1%) underwent blind biopsy. The sensitivity of hysteroscopically guided biopsy for the diagnosis of endometrial polyps ranged between 35.3 and 36.8%, when carried out at the apex and base of the lesion, compared with 29.2% for blind biopsy. Specificity was 33.3, 50, and 60%, respectively, for each biopsy. The positive predictive values were 75, 77.8, and 87.5%, and negative predictive values were 8.3, 14.3, and 8.1% respectively, compared with surgical polypectomy specimens. The office-based endometrial biopsies had low diagnostic accuracy for endometrial polyps compared with surgical polypectomy specimens. PMID:27638896

  8. Accuracy evaluation of a 3D ultrasound-guided biopsy system

    NASA Astrophysics Data System (ADS)

    Wooten, Walter J.; Nye, Jonathan A.; Schuster, David M.; Nieh, Peter T.; Master, Viraj A.; Votaw, John R.; Fei, Baowei

    2013-03-01

    Early detection of prostate cancer is critical in maximizing the probability of successful treatment. Current systematic biopsy approach takes 12 or more randomly distributed core tissue samples within the prostate and can have a high potential, especially with early disease, for a false negative diagnosis. The purpose of this study is to determine the accuracy of a 3D ultrasound-guided biopsy system. Testing was conducted on prostate phantoms created from an agar mixture which had embedded markers. The phantoms were scanned and the 3D ultrasound system was used to direct the biopsy. Each phantom was analyzed with a CT scan to obtain needle deflection measurements. The deflection experienced throughout the biopsy process was dependent on the depth of the biopsy target. The results for markers at a depth of less than 20 mm, 20-30 mm, and greater than 30 mm were 3.3 mm, 4.7 mm, and 6.2 mm, respectively. This measurement encapsulates the entire biopsy process, from the scanning of the phantom to the firing of the biopsy needle. Increased depth of the biopsy target caused a greater deflection from the intended path in most cases which was due to an angular incidence of the biopsy needle. Although some deflection was present, this system exhibits a clear advantage in the targeted biopsy of prostate cancer and has the potential to reduce the number of false negative biopsies for large lesions.

  9. Shear punch testing of {sup 59}Ni isotopically-doped model austenitic alloys after irradiation in FFTF at different He/dpa ratios

    SciTech Connect

    Hankin, G.L.; Faulkner, R.G.; Hamilton, M.L.; Garner, F.A.

    1998-03-01

    A series of three model alloys, Fe-15Cr-25Ni, Fe-15Cr-25Ni-0.04P and Fe-15Cr45Ni were irradiated side-by-side in FFTF-MOTA in both the annealed and the cold worked condition in each of two variants, one using naturally occurring isotopic mixtures, and another doped with {sup 59}Ni to generate relatively high helium-to-dpa ratios. Previous papers in this series have addressed the influence of helium on radiation-induced evolution of microstructure, dimensional stability and mechanical properties, the latter using miniature-tensile specimens. In the final paper of this experimental series, three sets of irradiations conducted at different temperatures and displacement rates were examined by shear punch testing of standard microscopy disks. The results were used to determine the influence of helium generation rate, alloy starting condition, irradiation temperature and total neutron exposure. The results were also compared with the miniature tensile data obtained earlier. In general, all alloys approached saturation levels of strength and ductility that were relatively independent of He/dpa ratio and starting condition, but were sensitive to the irradiation temperature and total exposure. Some small influence of helium/dpa ratio on the shear strength is visible in the two series that ran at {approximately}490 C, but is not evident at 365 C.

  10. Progress toward optical biopsy: bringing the microscope to the patient.

    PubMed

    Newton, Richard C; Kemp, Samuel V; Shah, Pallav L; Elson, Daniel; Darzi, Ara; Shibuya, Kiyoshi; Mulgrew, Stephen; Yang, Guang-Zhong

    2011-04-01

    The investigation of many lung diseases currently requires bronchoscopic or surgical histopathological tissue biopsy. This creates risks for patients and entails processing costs and delays in diagnosis. However, several mainly probe-based biophotonic techniques that can image solitary lesions and diffuse lung diseases are fuelling a paradigm shift toward real-time in vivo diagnosis. Optical coherence tomography (OCT) uses near-infrared light in a process analogous to ultrasonography to image the mucosal and submucosal tissue boundaries of the bronchial tree. With 15-μm resolution, early work suggests it can differentiate between neoplasia, carcinoma in situ, dysplasia, and metaplasia based around epithelial thickness and breaches in the basement membrane. Probe-based confocal laser endomicroscopy (pCLE) has superior resolution but less penetration than OCT and employs blue argon laser light to fluoresce the endogenous elastin of (1) the acinar scaffold of the peripheral lung and (2) the basement membrane lying under bronchial mucosa. Initial studies suggest that the regular fibre arrangement of the basement membrane is altered in the presence of overlying malignant epithelium. pCLE produces detailed representations of the alveolar septal walls, microvessels, and some inflammatory cells. A third device, the endocytoscope, is a contact microscope requiring contrast agent to provide subcellular resolution of bronchial mucosa. Further development of these "optical biopsy" techniques and evaluation of diagnostic sensitivity and specificity of the acquired images are needed before they can be considered effective methods for eliminating the need for, and thus risks of, pinch biopsy to enable real-time diagnosis to streamline management.

  11. Efficacy of needle biopsy in postradiation thyroid disease

    SciTech Connect

    Rosen, I.B.; Palmer, J.A.; Bain, J.; Strawbridge, H.; Walfish, P.G.

    1983-12-01

    Retrospective review was carried out of 124 patients with nodular disease of the thyroid gland and a history of radiation exposure who had undergone needle aspiration biopsy. Latency period from time of radiation varied from 2 to 50 years; but in 92 patients it exceeded 2 decades. Our patient group included those with occupational exposure and a past history of radiation for cancer. Incidence of cancer in the entire group was 49% but, for solitary lesions, this was increased to 56%, while only a 30% incidence of cancer was found in cases of multinodular goiters. Accuracy of needle aspiration biopsy overall was 74%: for the group with cancer--90%, for the group with adenomas--65%, and for the group with ''benign'' tumors--83%. Further assessment of needle technique indicated a sensitivity of 70%, specificity of 90%, positive predictive value of 90%, and negative predictive value of 83% to 65%. The accuracy could be increased to 84% if all adenomas were considered as possible malignancies. Eighteen percent of our patients had second tumors in the head and neck or breast area. Near-total thyroidectomy was considered to be the preferred procedure without accidental nerve injury and was done in one case of hypoparathyroidism after excision of an extensive tracheal invasive cancer. No evidence of death, recurrence, or metastasis as a result of thyroid cancer has been noted. While needle biopsy is indispensable to intelligent management, the history of radiation to the head and neck area must be preeminent in the selection of patients for surgical treatment. Conservative management appears to be reasonable in those patients with ''benign'' cytology, a less than 1 cm nodule, multinodularity, a functioning thyroid scan result, but persistence in the face of a lack of response to conservative management does not appear to be warranted.

  12. Electron microscopy analysis of skin biopsies in CADASIL disease.

    PubMed

    Cotrutz, Carmen Elena; Indrei, Anca; Bădescu, L; Dacălu, Cristina; Neamţu, Monica; Dumitrescu, Gabriela Florenţa; Stefanache, Felicia; Petreuş, T

    2010-01-01

    Cerebral Autosomal Dominant Arteriopathy with Subcortical Infarcts and Leukoencephalopathy (CADASIL) is an inherited vascular disorder, non-amyloid and non-atherosclerotic, affecting predominantly the central nervous system. We examined samples of skin biopsies from six patients (men, 43-52-year-old), admitted for treatment in the Neurology Clinic regarding the presence of partial motor impairment on upper and lower right limbs, facial asymmetry and phrasing impairment (three of the patients); These three patients had family history remarkable for early-onset strokes: mother and two brothers deceased by early strokes (40-50-year-old). Skin biopsy samples were fixed in glutaraldehyde and post-fixed in osmium tetroxyde. After dehydration, tissue samples were embedded in Epon. Ultrathin sections were mounted on copper grids and stained with uranyl acetate and lead citrate as usual and examined with a transmission electron microscope Phillips CM100. In all cases ultrastructural study showed granular osmiophilic material (GOM) in extracellular locations, between degenerating smooth muscle cells in dermal arteries or in their indentations. Deposits of GOM varied in size and electron density. Degeneration and loss of smooth muscle cells (SMCs) leads to abnormal enlargement of the space between these cells Ultrastructural analysis in three cases showed chromatin condensation and peripheral aggregation of nuclear material suggesting cells entry to apoptosis. These aspects and the marked destruction of the vascular wall were correlated with MRI findings and the severity of clinical manifestations at these patients. Our study showed that findings of GOM deposits, degeneration and loss of SMCs (probably by apoptosis), cell adhesion elements disturbance are characteristic for CADASIL disease and sufficient for diagnose of certainty. Moreover, electron microscopy analysis of skin biopsies is a useful tool for a differential diagnosis and can be considered as first choice method

  13. Novel pathogenic mutations and skin biopsy analysis in Knobloch syndrome

    PubMed Central

    Suzuki, Oscar; Kague, Erika; Bagatini, Kelly; Tu, Hongmin; Heljasvaara, Ritva; Carvalhaes, Lorenza; Gava, Elisandra; de Oliveira, Gisele; Godoi, Paulo; Oliva, Glaucius; Kitten, Gregory; Pihlajaniemi, Taina; Passos-Bueno, Maria-Rita

    2009-01-01

    Purpose To facilitate future diagnosis of Knobloch syndrome (KS) and better understand its etiology, we sought to identify not yet described COL18A1 mutations in KS patients. In addition, we tested whether mutations in this gene lead to absence of the COL18A1 gene product and attempted to better characterize the functional effect of a previously reported missense mutation. Methods Direct sequencing of COL18A1 exons was performed in KS patients from four unrelated pedigrees. We used immunofluorescent histochemistry in skin biopsies to evaluate the presence of type XVIII collagen in four KS patients carrying two already described mutations: c.3277C>T, a nonsense mutation, and c.3601G>A, a missense mutation. Furthermore, we determined the binding properties of the mutated endostatin domain p.A1381T (c.3601G>A) to extracellular matrix proteins using ELISA and surface plasmon resonance assays. Results We identified four novel mutations in COL18A1, including a large deletion involving exon 41. Skin biopsies from KS patients revealed lack of type XVIII collagen in epithelial basement membranes and blood vessels. We also found a reduced affinity of p.A1381T endostatin to some extracellular matrix components. Conclusions COL18A1 mutations involved in Knobloch syndrome have a distribution bias toward the coding exons of the C-terminal end. Large deletions must also be considered when point mutations are not identified in patients with characteristic KS phenotype. We report, for the first time, lack of type XVIII collagen in KS patients by immunofluorescent histochemistry in skin biopsy samples. As a final point, we suggest the employment of this technique as a preliminary and complementary test for diagnosis of KS in cases when mutation screening either does not detect mutations or reveals mutations of uncertain effect, such as the p.A1381T change. PMID:19390655

  14. Experience with the advanced breast biopsy instrumentation system

    PubMed Central

    Perelman, Vsevolod S.; Colapinto, Nicholas D.; Lee, Stephen; Down, Nancy K.; Cook, Dodie M.

    2000-01-01

    Objectives To report early experience with the advanced breast biopsy instrumentation (ABBI) system and to compare the results with those of other published studies. Design A nonrandomized case series. Setting An outpatient breast diagnostic centre at a large urban community hospital. Patients Thirty-four women; 27 had suspicious calcifications, 2 had a nonpalpable mass and 5 had both. Intervention The ABBI procedure to excise a breast lesion or obtain a representative sample for histologic examination. Main outcome measures Success of the procedure with respect to diagnosis, sample quality, technical problems, margins of tumour free tissue and patient satisfaction. Results Malignant tissue was diagnosed in 7 women (21%) and atypical ductal hyperplasia in 2 (6%). In all cancers, the obtained samples had malignant cells present at the margins or less than 1 mm away. Technical problems were encountered in 32% of cases. Manual extraction of the specimen was required in 21% of cases. Conclusions The preliminary data correlate well with those of other published results. Although it is possible that a small number of cases and a relatively high proportion of technical difficulties may represent a normal learning curve, there is a definite need for improvement of some ABBI components. ABBI does not appear to provide adequate margins of uninvolved tissue in patients with cancer and thus should not be used with curative intent. ABBI provides excellent quality samples for pathological study and good patient satisfaction. There are not yet enough data for meaningful comparison of ABBI with stereotactic core biopsy and excisional biopsy with needle localization. PMID:11129832

  15. Diagnosis of breast cancer biopsies using quantitative phase imaging

    NASA Astrophysics Data System (ADS)

    Majeed, Hassaan; Kandel, Mikhail E.; Han, Kevin; Luo, Zelun; Macias, Virgilia; Tangella, Krishnarao; Balla, Andre; Popescu, Gabriel

    2015-03-01

    The standard practice in the histopathology of breast cancers is to examine a hematoxylin and eosin (H&E) stained tissue biopsy under a microscope. The pathologist looks at certain morphological features, visible under the stain, to diagnose whether a tumor is benign or malignant. This determination is made based on qualitative inspection making it subject to investigator bias. Furthermore, since this method requires a microscopic examination by the pathologist it suffers from low throughput. A quantitative, label-free and high throughput method for detection of these morphological features from images of tissue biopsies is, hence, highly desirable as it would assist the pathologist in making a quicker and more accurate diagnosis of cancers. We present here preliminary results showing the potential of using quantitative phase imaging for breast cancer screening and help with differential diagnosis. We generated optical path length maps of unstained breast tissue biopsies using Spatial Light Interference Microscopy (SLIM). As a first step towards diagnosis based on quantitative phase imaging, we carried out a qualitative evaluation of the imaging resolution and contrast of our label-free phase images. These images were shown to two pathologists who marked the tumors present in tissue as either benign or malignant. This diagnosis was then compared against the diagnosis of the two pathologists on H&E stained tissue images and the number of agreements were counted. In our experiment, the agreement between SLIM and H&E based diagnosis was measured to be 88%. Our preliminary results demonstrate the potential and promise of SLIM for a push in the future towards quantitative, label-free and high throughput diagnosis.

  16. Development of a 3D ultrasound-guided prostate biopsy system

    NASA Astrophysics Data System (ADS)

    Cool, Derek; Sherebrin, Shi; Izawa, Jonathan; Fenster, Aaron

    2007-03-01

    Biopsy of the prostate using ultrasound guidance is the clinical gold standard for diagnosis of prostate adenocarinoma. However, because early stage tumors are rarely visible under US, the procedure carries high false-negative rates and often patients require multiple biopsies before cancer is detected. To improve cancer detection, it is imperative that throughout the biopsy procedure, physicians know where they are within the prostate and where they have sampled during prior biopsies. The current biopsy procedure is limited to using only 2D ultrasound images to find and record target biopsy core sample sites. This information leaves ambiguity as the physician tries to interpret the 2D information and apply it to their 3D workspace. We have developed a 3D ultrasound-guided prostate biopsy system that provides 3D intra-biopsy information to physicians for needle guidance and biopsy location recording. The system is designed to conform to the workflow of the current prostate biopsy procedure, making it easier for clinical integration. In this paper, we describe the system design and validate its accuracy by performing an in vitro biopsy procedure on US/CT multi-modal patient-specific prostate phantoms. A clinical sextant biopsy was performed by a urologist on the phantoms and the 3D models of the prostates were generated with volume errors less than 4% and mean boundary errors of less than 1 mm. Using the 3D biopsy system, needles were guided to within 1.36 +/- 0.83 mm of 3D targets and the position of the biopsy sites were accurately localized to 1.06 +/- 0.89 mm for the two prostates.

  17. Biopsy Misidentification Identified by DNA Profiling in a Large Multicenter Trial

    PubMed Central

    Marberger, Michael; McConnell, John D.; Fowler, Ivy; Andriole, Gerald L.; Bostwick, David G.; Somerville, Matthew C.; Rittmaster, Roger S.

    2011-01-01

    Purpose The Reduction by Dutasteride of Prostate Cancer Events (REDUCE) prostate cancer risk reduction study randomly assigned 8,231 men to dutasteride or placebo for 4 years. Protocol-mandated biopsies were obtained after 2 and 4 years. After the discovery of three cases of biopsy sample misidentification in the first 2 years, all protocol-mandated biopsy samples were DNA tested to verify biopsy identity. Methods Biopsy and blood DNA profiling was performed retrospectively for the year 2 scheduled biopsies and prospectively for the year 4 scheduled biopsies. Toward the end of year 2, multiple changes were made to improve sample handling and chain of custody. Results Of the 6,458 year 2 and 4,777 year 4 biopsies, 26 biopsies reflecting 13 sample handling errors at year 2 (0.4%) and one biopsy reflecting one sample handling error at year 4 (0.02%) were confirmed to be mismatched to the patient for whom they were originally submitted. Of 6,733 reference blood samples profiled, 31 (0.5%) were found to be mismatched to the patient's verified identity profile. Sample identification errors occurred at local research sites and central laboratories. Conclusion Biopsy misidentification is a potential problem in clinical laboratories and clinical trials. Until now, biopsy misidentification has not been studied in the setting of a large, multinational clinical trial. In the REDUCE study, process improvement initiatives halfway through the trial dramatically reduced biopsy mismatches. The potential for biopsy mismatches in clinical trials and clinical practice is an under-recognized problem that requires rigorous attention to details of chain of custody and consideration of more widespread DNA identity testing. PMID:21444877

  18. Surgeon Influence on Use of Needle Biopsy in Patients With Breast Cancer: A National Medicare Study

    PubMed Central

    Eberth, Jan M.; Xu, Ying; Smith, Grace L.; Shen, Yu; Jiang, Jing; Buchholz, Thomas A.; Hunt, Kelly K.; Black, Dalliah M.; Giordano, Sharon H.; Whitman, Gary J.; Yang, Wei; Shen, Chan; Elting, Linda; Smith, Benjamin D.

    2014-01-01

    Purpose Use of needle biopsy is a proposed quality measure in the diagnosis and treatment of breast cancer, yet prior literature documents underuse. Nationally, little is known regarding the contribution of a patient's surgeon to needle biopsy use, and knowledge regarding downstream impact of needle biopsy on breast cancer care is incomplete. Methods Using 2003 to 2007 nationwide Medicare data from 89,712 patients with breast cancer and 12,405 surgeons, logistic regression evaluated the following three outcomes: surgeon consultation before versus after biopsy, use of needle biopsy (yes or no), and number of surgeries for cancer treatment. Multilevel analyses were adjusted for physician, patient, and structural covariates. Results Needle biopsy was used in 68.4% (n = 61,353) of all patients and only 53.7% of patients seen by a surgeon before biopsy (n = 32,953/61,312). Patient factors associated with surgeon consultation before biopsy included Medicaid coverage, rural residence, residence more than 8.1 miles from a radiologic facility performing needle biopsy, and no mammogram within 60 days before consultation. Among patients with surgeon consultation before biopsy, surgeon factors such as absence of board certification, training outside the United States, low case volume, earlier decade of medical school graduation, and lack of specialization in surgical oncology were negatively correlated with receipt of needle biopsy. Risk of multiple cancer surgeries was 33.7% for patients undergoing needle biopsy compared with 69.6% for those who did not (adjusted relative risk, 2.08; P < .001). Conclusion Needle biopsy is underused in the United States, resulting in a negative impact on breast cancer diagnosis and treatment. Surgeon-level interventions may improve needle biopsy rates and, accordingly, quality of care. PMID:24912900

  19. Fine-needle aspiration biopsy with a vacuum test tube.

    PubMed

    Fornage, B D

    1988-11-01

    A simple, low-cost, automatic aspiration system that makes use of vacuum test tubes designed for the drawing of venous blood has been used for real-time ultrasound (US)-guided fine-needle aspiration biopsy of 13 cysts (breast), an abscess (liver), and five solid (breast, liver, thyroid) masses. Because it allows the operator to perform aspiration with one hand while holding the real-time US transducer with the other, and because creation of the suction is associated with no significant displacement of the needle, this approach has allowed sampling of lesions less than 1 cm in diameter. No complications have occurred.

  20. [Image-guided stereotaxic biopsy of central nervous system lesions].

    PubMed

    Nasser, J A; Confort, C I; Ferraz, A; Esperança, J C; Duarte, F

    1998-06-01

    In a series of 44 image guided stereotactic biopsy from August 1995 until March 1997, findings were as follows (frequency order). Tumors, glioblastoma was the most frequent. Primary lymphoma and other conditions associated to AIDS. Metastasis, three cases, Vasculites, two cases, Arachnoid cyst, Creutzfeldt-Jakob, cortical degeneration, inespecific calcification (one case each). The age varied from 1 to 83 years. Forty one lesions were supratentorial, two infratentorial, and one was outside the brain (dura and skull) and we used stereotaxy to localize it. There was no mortality and morbidity was 2.3%. The literature is reviewed. We conclude that this procedure is safe and highly diagnostic.

  1. [Image-guided stereotaxic biopsy of central nervous system lesions].

    PubMed

    Nasser, J A; Confort, C I; Ferraz, A; Esperança, J C; Duarte, F

    1998-06-01

    In a series of 44 image guided stereotactic biopsy from August 1995 until March 1997, findings were as follows (frequency order). Tumors, glioblastoma was the most frequent. Primary lymphoma and other conditions associated to AIDS. Metastasis, three cases, Vasculites, two cases, Arachnoid cyst, Creutzfeldt-Jakob, cortical degeneration, inespecific calcification (one case each). The age varied from 1 to 83 years. Forty one lesions were supratentorial, two infratentorial, and one was outside the brain (dura and skull) and we used stereotaxy to localize it. There was no mortality and morbidity was 2.3%. The literature is reviewed. We conclude that this procedure is safe and highly diagnostic. PMID:9698729

  2. Needle aspiration cytologic biopsy in head and neck masses.

    PubMed

    Young, J E; Archibald, S D; Shier, K J

    1981-10-01

    Over 500 fine (no. 22) needle aspiration biopsies were done on head and neck lesions. The total accuracy for the series was 94.5 percent. The accuracy rates for thyroid, salivary and metastatic or benign lymph node lesions were similar: approximately 95 percent. Only lymphomatous lesions gave a lower accuracy rate: 75 percent. This method of evaluating masses in the head and neck is simple, rapid, inexpensive, well-tolerated and harmless, and is very accurate when there is close cooperation between the clinician and the cytopathologist.

  3. Liver biopsy: Analysis of results of two specialist teams

    PubMed Central

    Anania, Giulia; Gigante, Elia; Piciucchi, Matteo; Pilozzi, Emanuela; Pucci, Eugenio; Pellicelli, Adriano Maria; Capotondi, Carlo; Rossi, Michele; Baccini, Flavia; Antonelli, Giulio; Begini, Paola; Fave, Gianfranco Delle; Marignani, Massimo

    2014-01-01

    AIM: To analyze the safety and the adequacy of a sample of liver biopsies (LB) obtained by gastroenterologist (G) and interventional radiologist (IR) teams. METHODS: Medical records of consecutive patients evaluated at our GI unit from 01/01/2004 to 31/12/2010 for whom LB was considered necessary to diagnose and/or stage liver disease, both in the setting of day hospital and regular admission (RA) care, were retrieved and the data entered in a database. Patients were divided into two groups: one undergoing an ultrasonography (US)-assisted procedure by the G team and one undergoing US-guided biopsy by the IR team. For the first group, an intercostal approach (US-assisted) and a Menghini modified type needle 16 G (length 90 mm) were used. The IR team used a subcostal approach (US-guided) and a semiautomatic modified Menghini type needle 18 G (length 150 mm). All the biopsies were evaluated for appropriateness according to the current guidelines. The number of portal tracts present in each biopsy was assessed by a revision performed by a single pathologist unaware of the previous pathology report. Clinical, laboratory and demographic patient characteristics, the adverse events rate and the diagnostic adequacy of LB were analyzed. RESULTS: During the study period, 226 patients, 126 males (56%) and 100 females (44%), underwent LB: 167 (74%) were carried out by the G team, whereas 59 (26%) by the IR team. LB was mostly performed in a day hospital setting by the G team, while IR completed more procedures on inpatients (P < 0.0001). The groups did not differ in median age, body mass index (BMI), presence of comorbidities and coagulation parameters. Complications occurred in 26 patients (16 G team vs 10 IR team, P = 0.15). Most gross samples obtained were considered suitable for basal histological evaluation, with no difference among the two teams (96.4% G team vs 91.5% IR, P = 0.16). However, the samples obtained by the G team had a higher mean number of portal tracts (G

  4. Multimodal optical biopsy probe to improve the safety and diagnostic yield of brain needle biopsies (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Desroches, Joannie; Pichette, Julien; Goyette, Andréanne; Tremblay, Marie-Andrée.; Jermyn, Michael; Petrecca, Kevin; Leblond, Frédéric

    2016-03-01

    Brain needle biopsy (BNB) is performed to collect tissue when precise neuropathological diagnosis is required to provide information about tumor type, grade, and growth patterns. The principal risks associated with this procedure are intracranial hemorrhage (due to clipping blood vessels during tissue extraction), incorrect tumor typing/grading due to non-representative or non-diagnostic samples (e.g. necrotic tissue), and missing the lesion. We present an innovative device using sub-diffuse optical tomography to detect blood vessels and Raman spectroscopy to detect molecular differences between tissue types, in order to reduce the risks of misdiagnosis, incorrect tumour grading, and non-diagnostic samples. The needle probe integrates optical fibers directly onto the external cannula of a commercial BNB needle, and can perform measurements for both optical techniques through the same fibers. This integrated optical spectroscopy system uses diffuse reflectance signals to perform a 360-degree reconstruction of the tissue adjacent to the biopsy needle, based on the optical contrast associated with hemoglobin light absorption, thereby localizing blood vessels. Raman spectra measurements are also performed interstitially for tissue characterization. A detailed sensitivity of the system is presented to demonstrate that it can detect absorbers with diameters <300 µm located up to ˜2 mm from the biopsy needle core, for bulk optical properties consistent with brain tissue. Results from animal experiments are presented to validate blood vessel detection and Raman spectrum measurement without disruption of the surgical workflow. We also present phantom measurements of Raman spectra with the needle probe and a comparison with a clinically validated Raman spectroscopy probe.

  5. Implementing lessons learned from previous bronchial biopsy trials in a new randomized controlled COPD biopsy trial with roflumilast

    PubMed Central

    2014-01-01

    Background Chronic obstructive pulmonary disease (COPD) is a chronic inflammatory disease mediated by an array of inflammatory cells and mediators, but above all, CD8+ T-lymphocytes, macrophages and neutrophils are important players in disease pathogenesis. Roflumilast, a first-in-class, potent and selective phosphodiesterase 4 (PDE4) inhibitor, reduces the rate of exacerbations in patients with a high risk of future exacerbations and has been shown to reduce inflammatory cells and mediators in induced sputum, a surrogate of airway inflammation. However, these anti-inflammatory effects are yet to be confirmed in another robust study directly assessing inflammatory markers in bronchial sub-mucosa. Methods/Design An international, 16-week, randomized, double-blind, placebo-controlled, parallel-group study investigating the effects of roflumilast 500 μg once-daily versus placebo on inflammatory parameters in bronchial biopsy tissue specimens, sputum and blood serum. One hundred and fifty patients with COPD and chronic bronchitis for at least 12 months will be recruited into the study and randomized in a 1:1 ratio to receive either roflumilast or placebo. The primary endpoint will be the number of CD8+ cells (cell counts per mm2) in bronchial biopsy tissue specimens (sub-mucosa) and the key secondary endpoint will be the number of CD68+ cells (cell counts per mm2), assessed by indirect immunohistochemistry. Discussion It is hypothesized that treatment with roflumilast reduces the characteristic inflammation found in the airways of patients with moderate-to-severe COPD, compared with placebo. The design of the present study has built on the work of previous bronchial biopsy studies available in the literature. It is hoped that it will reveal the cellular mechanisms underlying the anti-inflammatory effects of roflumilast and identify potentially important biomarkers and other surrogate endpoints in patients with COPD. The design and rationale for this trial are

  6. Fine-needle biopsy of pediatric lesions: a three-year study in an outpatient biopsy clinic.

    PubMed

    Eisenhut, C C; King, D E; Nelson, W A; Olson, L C; Wall, R W; Glant, M D

    1996-02-01

    Diagnostic Cytology Laboratory, Inc., has an outpatient Fine Needle Biopsy Clinic, which evaluated 7,487 fine-needle biopsies (FNB) from January 1989 to February 1992. Two hundred eighty-eight (3.8%) of these specimens were collected from patients 19 years old or younger and this represents the largest study of this population in the scientific literature. The majority of these specimens were obtained from palpable masses in the head and neck region [lymph nodes (58.3%), thyroid (7.6%), and salivary gland (5.2%)] while a smaller number were collected from miscellaneous soft tissue (18.8%) and breast masses (10.1%). Thirteen (4.5%) (from 12 patients) were diagnosed as malignant by FNB and 275 (95.5%) (264 patients) were benign by FNB. This benign:malignant ratio (22:1) is significantly higher than has been reported from tertiary care institutions and is a reflection of the difference of this outpatient population. Two hundred nine of 276 patients (75.7%) had adequate follow-up, including 137 (49.6%) patients followed by observation, 48 (17.4%) patients followed by surgical biopsy, and 24 (8.7%) patients followed by some other modality: imaging studies, flow cytometry, or treatment. There was a single false positive diagnosis (a pilomatrixoma) and one (1) false negative interpretation (a cystic acinic cell carcinoma) resulting in a diagnostic sensitivity of 92.3% and a specificity of 99.6%. The positive predictive value was 92.3%, the negative predictive value was 99.6%, and the test efficiency was 99.3%. The utility, cost-effectiveness and uniqueness of the clinic population is discussed.

  7. Multiple cores of high grade prostatic intraepithelial neoplasia and any core of atypia on first biopsy are significant predictor for cancer detection at a repeat biopsy

    PubMed Central

    Kim, Tae Sun; Ko, Kwang Jin; Shin, Seung Jea; Ryoo, Hyun Soo; Song, Wan; Sung, Hyun Hwan; Han, Deok Hyun; Jeong, Byong Chang; Seo, Seong Il; Jeon, Seong Soo; Lee, Kyu Sung; Lee, Sung Won; Lee, Hyun Moo; Choi, Han Yong

    2015-01-01

    Purpose To investigate the differences in the cancer detection rate and pathological findings on a second prostate biopsy according to benign diagnosis, high-grade prostatic intraepithelial neoplasia (HGPIN), and atypical small acinar proliferation (ASAP) on first biopsy. Materials and Methods We retrospectively reviewed the records of 1,323 patients who underwent a second prostate biopsy between March 1995 and November 2012. We divided the patients into three groups according to the pathologic findings on the first biopsy (benign diagnosis, HGPIN, and ASAP). We compared the cancer detection rate and Gleason scores on second biopsy and the unfavorable disease rate after radical prostatectomy among the three groups. Results A total of 214 patients (16.2%) were diagnosed with prostate cancer on a second biopsy. The rate of cancer detection was 14.6% in the benign diagnosis group, 22.1% in the HGPIN group, and 32.1% in the ASAP group, respectively (p<0.001). When patients were divided into subgroups according to the number of positive cores, the rate of cancer detection was 16.7%, 30.5%, 31.0%, and 36.4% in patients with a single core of HGPIN, more than one core of HGPIN, a single core of ASAP, and more than one core of ASAP, respectively. There were no significant differences in Gleason scores on second biopsy (p=0.324) or in the unfavorable disease rate after radical prostatectomy among the three groups (benign diagnosis vs. HGPIN, p=0.857, and benign diagnosis vs. ASAP, p=0.957, respectively). Conclusions Patients with multiple cores of HGPIN or any core number of ASAP on a first biopsy had a significantly higher cancer detection rate on a second biopsy. Repeat biopsy should be considered and not be delayed in those patients. PMID:26682019

  8. Bronchoscopic procedures and lung biopsies in pediatric lung transplant recipients.

    PubMed

    Wong, Jackson Y; Westall, Glen P; Snell, Gregory I

    2015-12-01

    Bronchoscopy remains a pivotal diagnostic and therapeutic intervention in pediatric patients undergoing lung transplantation (LTx). Whether performed as part of a surveillance protocol or if clinically indicated, fibre-optic bronchoscopy allows direct visualization of the transplanted allograft, and in particular, an assessment of the patency of the bronchial anastomosis (or tracheal anastomosis following heart-lung transplantation). Additionally, bronchoscopy facilitates differentiation of infective processes from rejection episodes through collection and subsequent assessment of bronchoalveolar lavage (BAL) and transbronchial biopsy (TBBx) samples. Indeed, the diagnostic criteria for the grading of acute cellular rejection is dependent upon the histopathological assessment of biopsy samples collected at the time of bronchoscopy. Typically, performed in an out-patient setting, bronchoscopy is generally a safe procedure, although complications related to hemorrhage and pneumothorax are occasionally seen. Airway complications, including stenosis, malacia, and dehiscence are diagnosed at bronchoscopy, and subsequent management including balloon dilatation, laser therapy and stent insertion can also be performed bronchoscopically. Finally, bronchoscopy has been and continues to be an important research tool allowing a better understanding of the immuno-biology of the lung allograft through the collection and analysis of collected BAL and TBBx samples. Whilst new investigational tools continue to evolve, the simple visualization and collection of samples within the lung allograft by bronchoscopy remains the gold standard in the evaluation of the lung allograft. This review describes the use and experience of bronchoscopy following lung transplantation in the pediatric setting.

  9. Pancreatic cancer: Are "liquid biopsies" ready for prime-time?

    PubMed Central

    Lewis, Alexandra R; Valle, Juan W; McNamara, Mairead G

    2016-01-01

    Pancreatic cancer is a disease that carries a poor prognosis. Accurate tissue diagnosis is required. Tumours contain a high content of stromal tissue and therefore biopsies may be inconclusive. Circulating tumour cells (CTCs) have been investigated as a potential “liquid biopsy” in several malignancies and have proven to be of prognostic value in breast, prostate and colorectal cancers. They have been detected in patients with localised and metastatic pancreatic cancer with sensitivities ranging from 38%-100% using a variety of platforms. Circulating tumour DNA (ctDNA) has also been detected in pancreas cancer with a sensitivity ranging from 26%-100% in studies across different platforms and using different genetic markers. However, there is no clear consensus on which platform is the most effective for detection, nor which genetic markers are the most useful to use. Potential roles of liquid biopsies include diagnosis, screening, guiding therapies and prognosis. The presence of CTCs or ctDNA has been shown to be of prognostic value both at diagnosis and after treatment in patients with pancreatic cancer. However, more prospective studies are required before this promising technology is ready for adoption into routine clinical practice. PMID:27621566

  10. Fast Diagnostics of BRAF Mutations in Biopsies from Malignant Melanoma.

    PubMed

    Huber, François; Lang, Hans Peter; Glatz, Katharina; Rimoldi, Donata; Meyer, Ernst; Gerber, Christoph

    2016-09-14

    According to the American skin cancer foundation, there are more new cases of skin cancer than the combined incidence of cancers of the breast, prostate, lung, and colon each year, and malignant melanoma represents its deadliest form. About 50% of all cases are characterized by a particular mutation BRAF(V600E) in the BRAF (Rapid Acceleration of Fibrosarcoma gene B) gene. Recently developed highly specific drugs are able to fight BRAF(V600E) mutated tumors but require diagnostic tools for fast and reliable mutation detection to warrant treatment efficiency. We completed a preliminary clinical trial applying cantilever array sensors to demonstrate identification of a BRAF(V600E) single-point mutation using total RNA obtained from biopsies of metastatic melanoma of diverse sources (surgical material either frozen or fixated with formalin and embedded in paraffin). The method is faster than the standard Sanger or pyrosequencing methods and comparably sensitive as next-generation sequencing. Processing time from biopsy to diagnosis is below 1 day and does not require PCR amplification, sequencing, and labels. PMID:27490749

  11. A case of sporadic intestinal cryptosporidiosis diagnosed by endoscopic biopsy.

    PubMed

    Ogata, Sho; Suganuma, Toshiyuki; Okada, Chizuko; Inoue, Kimitoshi; Kinoshita, Akio; Sato, Kimiya

    2009-10-01

    Sporadic intestinal cryptosporidiosis is not easily diagnosed and might be overlooked. We present here a case of this disease in a 23-year-old Japanese military man with 3 days of abdominal pain, watery diarrhea, and nausea. The frequency of his diarrhea was more than 10 times per day. After his diarrheal bowel symptoms subsided, a colonoscopy was performed because inflammatory bowel disease was suspected. Although the endoscopic findings indicated non-specific ileitis, intestinal cryptosporidiosis was suspected from the histology of ileal biopsy specimens, and this was confirmed ultrastructurally. At that time, however, the patient was on active duty, and thus it was not possible to confirm this as a definitive diagnosis by an adequate stool examination for cryptosporidium. Routine practitioners should be encouraged to carefully inspect patients for this disease, supported by detailed knowledge of it and its diagnosis. If stool-examination results are negative or are not obtained at first, histological diagnosis by endoscopic biopsy could be a useful way to screen for intestinal cryptosporidiosis. Furthermore, stool or histological examination should be performed in recovered patients because the oocysts may continue to be shed for 1 to 4 weeks after the symptoms disappear. Therefore, endoscopic and histological examinations may be useful tools for the early diagnosis of intestinal cryptosporidiosis, although admittedly they are invasive procedures.

  12. Testicular biopsy in prepubertal boys: a worthwhile minor surgical procedure?

    PubMed

    Faure, Alice; Bouty, Aurore; O'Brien, Mike; Thorup, Jorgen; Hutson, John; Heloury, Yves

    2016-03-01

    No consensus exists regarding the precise role of testicular biopsy in prepubertal boys, although it is considered useful for assessing the potential consequences of undescended testes on fertility. Current scientific knowledge indicates that surgeons should broaden indications for this procedure. For example, the use of immunohistochemical markers such as OCT/3-4, TSPY, Kit ligand (SCF) and ALPP (PLAP) has considerably facilitated the detection of germ cell tumour precursors, such as carcinoma in situ and/or gonadoblastoma. These markers are very important for evaluating malignancy risk in undervirilized patients with 46,XY disorders of sexual development. Testicular histology is also of considerable value in the prediction of both fertility potential and risk of cancer in individuals with undescended testes, particularly those with intraabdominal undescended testes. New possibilities for the preservation of fertility after gonadotoxic chemotherapy - even for prepubertal boys - are emerging. Cryopreservation of testicular tissue samples for the preservation of fertility - although still an experimental method at present - is appealing in this context. In our opinion, testicular biopsy in prepubertal boys is a minor procedure that can provide valuable information for predicting the risk of malignancy and fertility, and might be useful in fertility preservation in the near future. PMID:26787392

  13. Liquid Biopsy of Hepatocellular Carcinoma: Circulating Tumor-Derived Biomarkers

    PubMed Central

    Yuan, Chun-Hui; Qu, Zhen; Guan, Qing; Chen, Hao

    2016-01-01

    Hepatocellular carcinoma (HCC) is the second leading cause of cancer-related death worldwide due to latent liver disease, late diagnosis, and nonresponse to systemic treatments. Till now, surgical and/or biopsy specimens are still generally used as a gold standard by the clinicians for clinical decision-making. However, apart from their invasive characteristics, tumor biopsy only mirrors a single spot of the tumor, failing to reflect current cancer dynamics and progression. Therefore, it is imperative to develop new diagnostic strategies with significant effectiveness and reliability to monitor high-risk populations and detect HCC at an early stage. In the past decade, the potent utilities of “liquid biopsy” have attracted intense concern and were developed to evaluate cancer progression in several clinical trials. “Liquid biopsies” represent a series of noninvasive tests that detect cancer byproducts easily accessible in peripheral blood, mainly including circulating tumor cells (CTCs) and cell-free nucleic acids (cfNAs) that are shed into the blood from the tumor sites. In this review, we focus on the recent developments in the field of “liquid biopsy” as well as the diagnostic and prognostic significance of CTCs and cfNAs in HCC patients. PMID:27403030

  14. Foot Pad Skin Biopsy in Mouse Models of Hereditary Neuropathy

    PubMed Central

    Dacci, Patrizia; Dina, Giorgia; Cerri, Federica; Previtali, Stefano Carlo; Lopez, Ignazio Diego; Lauria, Giuseppe; Feltri, Maria Laura; Bolino, Alessandra; Comi, Giancarlo; Wrabetz, Lawrence; Quattrini, Angelo

    2010-01-01

    Numerous transgenic and knockout mouse models of human hereditary neuropathies have become available over the past decade. We describe a simple, reproducible, and safe biopsy of mouse skin for histopathological evaluation of the peripheral nervous system (PNS) in models of hereditary neuropathies. We compared the diagnostic outcome between sciatic nerve and dermal nerves found in skin biopsy (SB) from the hind foot. A total of five animal models of different Charcot-Marie-Tooth neuropathies, and one model of congenital muscular dystrophy associated neuropathy were examined. In wild type mice, dermal nerve fibers were readily identified by immunohistochemistry, light, and electron microscopy and they appeared similar to myelinated fibers in sciatic nerve. In mutant mice, SB manifested myelin abnormalities similar to those observed in sciatic nerves, including hypomyelination, onion bulbs, myelin outfolding, redundant loops, and tomacula. In many strains, however, SB showed additional abnormalities—fiber loss, dense neurofilament packing with lower phosphorylation status, and axonal degeneration—undetected in sciatic nerve, possibly because SB samples distal nerves. SB, a reliable technique to investigate peripheral neuropathies in human beings, is also useful to investigate animal models of hereditary neuropathies. Our data indicate that SB may reveal distal axonal pathology in mouse models and permits sequential follow-up of the neuropathy in an individual mouse, thereby reducing the number of mice necessary to document pathology of the PNS. © 2010 Wiley-Liss, Inc. PMID:20878767

  15. MRI-Safe Robot for Endorectal Prostate Biopsy

    PubMed Central

    Stoianovici, Dan; Kim, Chunwoo; Srimathveeravalli, Govindarajan; Sebrecht, Peter; Petrisor, Doru; Coleman, Jonathan; Solomon, Stephen B.; Hricak, Hedvig

    2014-01-01

    This paper reports the development of an MRI-Safe robot for direct (interventional) MRI-guided endorectal prostate biopsy. The robot is constructed of nonmagnetic and electrically nonconductive materials, and is electricity free, using pneumatic actuation and optical sensors. Targeting biopsy lesions of MRI abnormality presents substantial clinical potential for the management of prostate cancer. The paper describes MRI-Safe requirements, presents the kinematic architecture, design and construction of the robot, and a comprehensive set of preclinical tests for MRI compatibility and needle targeting accuracy. The robot has a compact and simple 3 degree-of-freedom (DoF) structure, two for orienting a needle-guide and one to preset the depth of needle insertion. The actual insertion is performed manually through the guide and up to the preset depth. To reduce the complexity and size of the robot next to the patient, the depth setting DoF is remote. Experimental results show that the robot is safe to use in any MRI environment (MRI-Safe). Comprehensive MRI tests show that the presence and motion of the robot in the MRI scanner cause virtually no image deterioration or signal to noise ratio (SNR) change. Robot’s accuracy in bench test, CT-guided in-vitro, MRI-guided in-vitro and animal tests are 0.37mm, 1.10mm, 2.09mm, and 2.58mm respectively. These values are acceptable for clinical use. PMID:25378897

  16. Pancreatic cancer: Are "liquid biopsies" ready for prime-time?

    PubMed Central

    Lewis, Alexandra R; Valle, Juan W; McNamara, Mairead G

    2016-01-01

    Pancreatic cancer is a disease that carries a poor prognosis. Accurate tissue diagnosis is required. Tumours contain a high content of stromal tissue and therefore biopsies may be inconclusive. Circulating tumour cells (CTCs) have been investigated as a potential “liquid biopsy” in several malignancies and have proven to be of prognostic value in breast, prostate and colorectal cancers. They have been detected in patients with localised and metastatic pancreatic cancer with sensitivities ranging from 38%-100% using a variety of platforms. Circulating tumour DNA (ctDNA) has also been detected in pancreas cancer with a sensitivity ranging from 26%-100% in studies across different platforms and using different genetic markers. However, there is no clear consensus on which platform is the most effective for detection, nor which genetic markers are the most useful to use. Potential roles of liquid biopsies include diagnosis, screening, guiding therapies and prognosis. The presence of CTCs or ctDNA has been shown to be of prognostic value both at diagnosis and after treatment in patients with pancreatic cancer. However, more prospective studies are required before this promising technology is ready for adoption into routine clinical practice.

  17. Laser-induced differential fluorescence for cancer diagnosis without biopsy

    SciTech Connect

    Vo-Dinh, T.; Panjehpour, M.; Overholt, B.F.; Buckley III, P.

    1997-01-01

    An optical diagnostic procedure based on laser-induced fluorescence was developed for direct {ital in vivo} cancer diagnosis without requiring biopsy. The methodology was applied in a clinical study involving over 100 patients in order to differentiate normal tissue from malignant tumors of the esophagus. Endogenous fluorescence of normal and malignant tissues was measured directly with the use of a fiber-optic probe inserted through an endoscope. The measurements were performed {ital in vivo} during routine endoscopy. Detection of the fluorescence signal from the tissue was performed with the use of laser excitation. This report describes the differential normalized fluorescence (DNF) procedure using the amplified spectral differences between the normalized fluorescence of malignant tissue and normal mucosa. The results of this DNF approach were compared with histopathology results of the biopsy samples and indicated excellent agreement in the classification of normal tissue and malignant tumors for the samples investigated. Data related to various grades of Barrett{close_quote}s esophagus are discussed. The DNF procedure could lead to the development of a rapid and cost-effective technique for cancer diagnosis. {copyright} {ital 1997} {ital Society for Applied Spectroscopy}

  18. Role of Percutaneous Image Guided Biopsy in Spinal Lesions: Adequacy and Correlation with MRI Findings

    PubMed Central

    2016-01-01

    Introduction Although, MRI has increased our understanding of spinal pathologies, accurate diagnosis of spinal lesions need biopsy, so that early treatment can be initiated. Aim To evaluate the accuracy of biopsy, safety and yield of percutaneously done image guided spinal biopsy using a large bore needle and correlate between MRI findings and biopsy as well as the importance of various MRI findings in establishing the diagnosis. Materials and Methods All spinal lesions after clinical and MRI evaluation were subjected to Jamshidi Needle biopsy using 11 gauge needles. Biopsy material was sent for culture/sensitivity, AFB smear and histopathological examination. The outcome assessment included percentage of patients in whom diagnosis was changed after biopsy, yield in biopsy and complications of biopsy. MRI findings, biopsy findings and final diagnosis were correlated to know the sensitivity and specificity of MRI and biopsy diagnosis. Logistic regression analysis was used to study the importance of each of MRI findings in making a diagnosis. Results Forty five patients with spinal lesions underwent biopsy using an 11 gauge Jamshidi needle. Initial biopsy was inconclusive in 4 patients giving a positive yield in about 91.2% of cases and a repeat biopsy ensured conclusive report in all cases. Following biopsy there was a change in diagnosis in 8% cases. MRI showed sensitivity of 85.71% and specificity of 93.54% for the diagnosis of malignancy and sensitivity of 85.71% and specificity of 86.48% for the diagnosis of tuberculosis. In contrast, initial biopsy had sensitivity of 92.85% and specificity of 100% for the diagnosis of malignancy and sensitivity of 71.42% and specificity of 100 % for the diagnosis of infection. Logistic regression analysis showed good correlation between malignancy and posterior bugle in the vertebral body in the absence of a fracture (p = 0.007), involvement of pedicles and posterior elements (p = 0.001) and soft tissue extension (p = 0

  19. Atypical apocrine adenosis diagnosed on breast core biopsy: implications for management.

    PubMed

    Calhoun, Benjamin C; Booth, Christine N

    2014-10-01

    Apocrine adenosis (AA) and atypical apocrine adenosis (AAA) are uncommon findings in breast biopsies that may be misinterpreted as carcinoma. The data from long-term follow up studies of open biopsies suggest that AAA is not a high-risk or precursor lesion. The clinical significance and risk implications of AAA diagnosed on core biopsy are not well established. The goal of this study was to determine the frequency of carcinoma in excision specimens after a core biopsy diagnosis of AA or AAA. We identified 34 core biopsies of AA (22) and AAA (12) performed between 1996 and 2014. The mean age at diagnosis was 60 years. The most common indications for core biopsy were calcifications (11), a mass or density (18), and a mass or density with calcifications (3). Two cases were detected on magnetic resonance imaging (MRI) studies. Available pathology reports and slides were reviewed, and surgical excision findings were correlated with core biopsy diagnoses. Of the core biopsies with AA or AAA, 7 also contained atypical ductal or lobular hyperplasia (AH) and 4 contained ductal carcinoma in situ or invasive carcinoma. In the absence of coexisting AH or carcinoma in the initial core biopsy specimen, none of the surgical excision specimens after a diagnosis of AA (2) or AAA (7) contained ductal carcinoma in situ or invasive carcinoma. AAA by itself is an uncommon core biopsy diagnosis that may not require surgical excision.

  20. Human breast cancer biopsies induce eosinophil recruitment and enhance adjacent cancer cell proliferation.

    PubMed

    Szalayova, Gabriela; Ogrodnik, Aleksandra; Spencer, Brianna; Wade, Jacqueline; Bunn, Janice; Ambaye, Abiy; James, Ted; Rincon, Mercedes

    2016-06-01

    Chronic inflammation is known to facilitate cancer progression and metastasis. Less is known about the effect of acute inflammation within the tumor microenvironment, resulting from standard invasive procedures. Recent studies in mouse models have shown that the acute inflammatory response triggered by a biopsy in mammary cancer increases the frequency of distal metastases. Although tumor biopsies are part of the standard clinical practice in breast cancer diagnosis, no studies have reported their effect on inflammatory response. The objective of this study is to (1) determine whether core needle biopsies in breast cancer patients trigger an inflammatory response, (2) characterize the type of inflammatory response present, and (3) evaluate the potential effect of any acute inflammatory response on residual tumor cells. The biopsy wound site was identified in the primary tumor resection tissue samples from breast cancer patients. The inflammatory response in areas adjacent (i.e., immediately around previous biopsy site) and distant to the wound biopsy was investigated by histology and immunohistochemistry analysis. Proliferation of tumor cells was also assayed. We demonstrate that diagnostic core needle biopsies trigger a selective recruitment of inflammatory cells at the site of the biopsy, and they persist for extended periods of time. While macrophages were part of the inflammatory response, an unexpected accumulation of eosinophils at the edge of the biopsy wound was also identified. Importantly, we show that biopsy causes an increase in the proliferation rate of tumor cells located in the area adjacent to the biopsy wound. Diagnostic core needle biopsies in breast cancer patients do induce a unique acute inflammatory response within the tumor microenvironment and have an effect on the surrounding tumor cells. Therefore, biopsy-induced inflammation could have an impact on residual tumor cell progression and/or metastasis in human breast cancer. These findings

  1. The effect of excisional biopsy on the accuracy of sentinel lymph node mapping in early stage breast cancer: comparison with core needle biopsy.

    PubMed

    Forghani, Mohammad Naser; Memar, Bahram; Jangjoo, Ali; Zakavi, Rasoul; Mehrabibahar, Mostafa; Kakhki, Vahid Reza Dabbagh; Kashani, Ida; Hashemian, Farnaz; Sadeghi, Ramin

    2010-11-01

    Despite the successful application of sentinel node mapping in breast cancer patients, its use in patients with a history of previous excisional biopsy of the breast tumors is a matter of controversy. In the present study we evaluated the accuracy of sentinel node biopsy in this group of patients and compared the results with those in whom the diagnosis of breast cancer was established by core needle biopsy. Eighty patients with early stage breast carcinoma were included into our study. Forty patients had a history of previous excisional biopsy and the remainder 40 had undergone core needle biopsy. Intradermal injections of 99mTc-antimony sulfide colloid as well as patent blue were both used for sentinel node mapping. Sentinel nodes were harvested during surgery with the aid of surgical gamma probe. All patients underwent standard axillary lymph node dissection subsequently. Detection rate was 97.5 per cent for both groups of the study. Number of detected sentinel node during surgery was not significantly different between groups. False negative rate was 0 per cent for both groups of the study. In conclusion sentinel node biopsy is reliable in patients with previous history of excisional biopsy of the breast tumors and has a low false negative rate.

  2. Percutaneous perirenal thrombin injection for the treatment of acute hemorrhage after renal biopsy.

    PubMed

    Mafeld, Sebastian; McNeill, Michael; Haslam, Philip

    2016-01-01

    Percutaneous renal biopsy is a valuable diagnostic approach. While commonly safe, it is not without risk and the most feared vascular complications include hemorrhage, pseudoaneurysm, and arteriovenous fistula formation. We report a case of acute hemorrhage after renal biopsy that was immediately identified by ultrasonography and successfully treated with percutaneous perirenal thrombin injection. This technique may prove a useful addition to the armamentarium of any operator performing renal biopsies.

  3. Percutaneous perirenal thrombin injection for the treatment of acute hemorrhage after renal biopsy

    PubMed Central

    Mafeld, Sebastian; McNeill, Michael; Haslam, Philip

    2016-01-01

    Percutaneous renal biopsy is a valuable diagnostic approach. While commonly safe, it is not without risk and the most feared vascular complications include hemorrhage, pseudoaneurysm, and arteriovenous fistula formation. We report a case of acute hemorrhage after renal biopsy that was immediately identified by ultrasonography and successfully treated with percutaneous perirenal thrombin injection. This technique may prove a useful addition to the armamentarium of any operator performing renal biopsies. PMID:26809832

  4. Anterior prostate biopsy at initial and repeat evaluation: is it useful to detect significant prostate cancer?

    PubMed Central

    Pepe, Pietro; Pennisi, Michele; Fraggetta, Filippo

    2015-01-01

    ABSTRACT Purpose: Detection rate for anterior prostate cancer (PCa) in men who underwent initial and repeat biopsy has been prospectively evaluated. Materials and Methods: From January 2013 to March 2014, 400 patients all of Caucasian origin (median age 63.5 years) underwent initial (285 cases) and repeat (115 cases) prostate biopsy; all the men had negative digital rectal examination and the indications to biopsy were: PSA values > 10 ng/mL, PSA between 4.1-10 or 2.6-4 ng/mL with free/total PSA≤25% and ≤20%, respectively. A median of 22 (initial biopsy) and 31 cores (repeat biopsy) were transperineally performed including 4 cores of the anterior zone (AZ) and 4 cores of the AZ plus 2 cores of the transition zone (TZ), respectively. Results: Median PSA was 7.9 ng/mL; overall, a PCa was found in 180 (45%) patients: in 135 (47.4%) and 45 (36%) of the men who underwent initial and repeat biopsy, respectively. An exclusive PCa of the anterior zone was found in the 8.9 (initial biopsy) vs 13.3% (repeat biopsy) of the men: a single microfocus of cancer was found in the 61.2% of the cases; moreover, in 7 out 18 AZ PCa the biopsy histology was predictive of significant cancer in 2 (28.5%) and 5 (71.5%) men who underwent initial and repeat biopsy, respectively. Conclusions: However AZ biopsies increased detection rate for PCa (10% of the cases), the majority of AZ PCa with histological findings predictive of clinically significant cancer were found at repeat biopsy (about 70% of the cases). PMID:26689509

  5. Accessible or Inaccessible? Diagnostic Efficacy of CT-Guided Core Biopsies of Head and Neck Masses

    SciTech Connect

    Cunningham, Jane D. McCusker, Mark W.; Power, Sarah; PearlyTi, Joanna; Thornton, John; Brennan, Paul; Lee, Michael J.; O’Hare, Alan; Looby, Seamus

    2015-04-15

    PurposeTissue sampling of lesions in the head and neck is challenging due to complex regional anatomy and sometimes necessitates open surgical biopsy. However, many patients are poor surgical candidates due to comorbidity. Thus, we evaluated the use of CT guidance for establishing histopathological diagnosis of head and neck masses.MethodsAll consecutive patients (n = 22) who underwent CT-guided core biopsy of head or neck masses between April 2009 and August 2012 were retrospectively reviewed using the departmental CT interventional procedures database. The indication for each biopsy performed was to establish or exclude a diagnosis of neoplasia in patients with suspicious head or neck lesions found on clinical examination or imaging studies. Patients received conscious sedation and 18 G, semiautomated core needle biopsies were performed by experienced neuroradiologists using 16-slice multidetector row CT imaging guidance (Somatom Definition Siemens Medical Solutions, Germany). Histopathology results of each biopsy were analysed.ResultsSixteen of 22 biopsies that were performed (73 %) yielded a pathological diagnosis. Anatomic locations biopsied included: masticator (n = 7), parapharyngeal (n = 3), parotid (n = 3), carotid (n = 3), perivertebral (n = 3), pharyngeal (n = 2), and retropharyngeal (n = 1) spaces. Six biopsies (27 %) were nondiagnostic due to inadequate tissue sampling, particularly small biopsy sample size and failure to biopsy the true sampling site due to extensive necrosis. No major complications were encountered.ConclusionsThe use of CT guidance to perform core biopsies of head and neck masses is an effective means of establishing histopathological diagnosis and reduces the need for diagnostic open surgical biopsy and general anaesthesia.

  6. Emergent Embolization of Arterial Bleeding after Vacuum-Assisted Breast Biopsy

    SciTech Connect

    Fischman, Aaron M.; Epelboym, Yan; Siegelbaum, Robert H. Weintraub, Joshua L. Kim, Edward Nowakowski, Francis S. Lookstein, Robert A.

    2012-02-15

    Vacuum-assisted core breast biopsy has become important in evaluating patients with suspicious breast lesions. It has proven to be a relatively safe procedure that in rare cases can result in vascular complications. These are the first reported cases of transcatheter embolization of uncontrolled breast hemorrhage after vacuum-assisted breast biopsy. With increased use of biopsy and larger-gauge devices, breast imaging groups may consider embolotherapy as a safe alternative for treatment of hemorrhage in a select group of patients.

  7. Behavioral and Activity Assessment of Laboratory Mice (Mus musculus) after Tail Biopsy under Isoflurane Anesthesia

    PubMed Central

    Hankenson, F Claire; Braden-Weiss, Gillian C; Blendy, Julie A

    2011-01-01

    Contemporary laboratory animal guidance suggests that tail biopsy of laboratory mice can be performed before 21 d of age without anesthesia, whereas older mice must receive anesthesia before biopsy. Our objective was to determine whether administration of isoflurane anesthesia before tail biopsy produced a measurable effect on the behavior of mice (n = 196). We evaluated C57BL/6 and BALB/c mice at 21 to 24 (weaning), 28 to 31 (delayed weaning), and 42 to 45 (adult) d of age. Mice were observed at the time of biopsy and then twice within the first hour after a sham or tail biopsy. Anxiety-like responses were assessed by using an elevated plus-maze. Activity was evaluated remotely for 120 min. Isoflurane did not diminish acute responses to tail biopsy in mice 31 d or younger compared with sham-biopsied animals but had a significant effect in C57BL/6 biopsied adult mice. In addition, mice of all ages and strains that received anesthesia, regardless of biopsy, spent more time in the enclosed maze arms and had decreased activity up to 5 h after isoflurane exposure. Although tail biopsy should be performed in young mice to avoid transection of distal mature vertebrae, our experimental paradigm indicates that isoflurane anesthesia does not appreciably enhance wellbeing over that of mice biopsied without anesthesia at weaning ages. The influence of inhaled isoflurane was demonstrable and indicated that acute and prolonged alterations in anxiety and activity must be considered when interpreting the impact of anesthesia on tail biopsy across various ages and strains of laboratory mice. PMID:22330716

  8. A review of needle core biopsy diagnosed radial scars in the Welsh Breast Screening Programme

    PubMed Central

    Osborn, G; Wilton, F; Stevens, G; Vaughan-Williams, E; Gower-Thomas, K

    2010-01-01

    INTRODUCTION Radial scars are benign breast lesions; their appearance on mammography may, however, mimic carcinoma. Needle core biopsy is performed for pre-operative diagnosis and, currently in Wales, all lesions with benign biopsy results are surgically excised. We have reviewed all cases of needle core biopsy-diagnosed radial scars from the Welsh breast screening programme, Breast Test Wales (BTW), and investigated the outcome of radial scars based on histology from surgical excision in order to evaluate the appropriateness of the current management of these lesions in Wales. PATIENTS AND METHODS All needle core biopsy diagnosed radial scars were identified from the BTW screening database from the start of screening in 1989 until the end of 2007. RESULTS A total of 118 patients were diagnosed with radial scars on needle core biopsy; two patients had bilateral radial scars. Median patient age was 54 years (range, 49-68 years). Ninety-five lesions (79%) were thought to be pure radial scars on needle core biopsy; however, only 81 pure radial scars were identified on excision biopsy histology. Carcinoma was present in seven patients and ductal carcinoma in situ in nine patients at excision biopsy. In two patients, the cancers occurred in lesions reported as pure radial scars on needle core biopsy. Twenty-two lesions showed atypical ductal or lobular hyperplasia (ADH/ALH) or both on excision biopsy; 14 of these lesions were classed as pure radial scars by needle core biopsy. CONCLUSIONS All core biopsy diagnosed radial scars, presenting as screen detected abnormalities, should be excised due to their association with premalignant and malignant conditions. PMID:21073820

  9. Suction-modified needle biopsy technique for the human soleus muscle

    PubMed Central

    Cotter, Joshua A.; Yu, Alvin; Kreitenberg, Arthur; Haddad, Fadia H.; Baker, Michael J.; Fox, John C.; Adams, Gregory R.

    2014-01-01

    INTRODUCTION The needle biopsy technique for the soleus muscle is of particular interest because of its unique fiber type distribution, contractile properties, and sensitivity to unloading. Unlike other commonly biopsied muscles, the soleus is not fully superficial and is in close proximity to neurovascular structures resulting in a more challenging biopsy. Because of this, a standardized protocol for performing needle biopsies on the human soleus muscle that is safe, reliable, and repeatable is presented. METHODS Ultrasonography was used on an initial set of 12 subjects to determine the optimal biopsy zone thereby guiding the location of the incision site. Forty-five subjects were recruited and attended two separate biopsy sessions. Each biopsy session incorporated 3 passes of the biopsy needle proximal, posterior, and distal using suction from a portable vacuum source producing 3 separate muscle specimens. RESULTS Eighty-four soleus muscle biopsy procedures were successfully conducted yielding 252 total samples without complication. Ultrasonography was used to confirm biopsy needle infiltration of the soleus muscle. Average sample weight obtained per pass was 61.5 ± 15.7 mg. Histochemistry and molecular analyses demonstrated a considerably higher amount of slow type I MHC in comparison to the vastus lateralis providing verification for the successful sampling of the soleus muscle. DISCUSSION The procedure presented consists of a detailed protocol to accurately and consistently obtain muscle biopsy samples from the human soleus muscle. We have demonstrated that the human soleus biopsy is a safe, reliable and repeatable procedure providing ample tissue for multiple types of analyses. PMID:24261060

  10. [The value of fine needle biopsy in the diagnosis of tumors of the salivary glands].

    PubMed

    Fière, A; Cartier, E; Breton, P; Faucon, M; Freidel, M

    1990-01-01

    Aspiration biopsy by fine needle from the major salivary glands has been studied. To evaluate this form of biopsy, 34 patients with salivary gland enlargement were examined. By this technic, 29 has confirmative histology. The method proved complication free and accurate. The safety of this biopsy form has been proven. The accuracy of this method may be high, particularly, for the most common benign mixed tumor. Thus this procedure is suggested for initial examination of all lesions of the salivary gland.

  11. Sentinel lymph node biopsy in paediatric melanoma. A case series.

    PubMed

    Sánchez Aguilar, M; Álvarez Pérez, R M; García Gómez, F J; Fernández Ortega, P; Borrego Dorado, I

    2015-01-01

    The incidence of melanoma in children is uncommon, being particularly rare in children under 10 years-old. However, this disease is increasing by a mean of 2% per year. As in adults, the lymph node status is the most important prognostic factor, crucial to performing the selective sentinel lymph node biopsy (SLNB). We report 3 cases of paediatric patients of 3, 4 and 8 years-old, in which SLNB was performed for malignant melanoma. Paediatric age implies greater technical difficulty to the scintigraphy scan due to poor patient cooperation, with mild sedation required in some cases, and only being able to acquire planar images in other cases. SPECT/CT was only performed in the oldest patient. In our cases, SLNB was useful for selecting the least invasive surgery in order to reduce morbidity.

  12. Axillary web syndrome following sentinel node biopsy for breast cancer.

    PubMed

    Nieves Maldonado, S M; Pubul Núñez, V; Argibay Vázquez, S; Macías Cortiñas, M; Ruibal Morell, Á

    2016-01-01

    A 49 year-old woman diagnosed with infiltrating lobular breast carcinoma, underwent a right mastectomy and sentinel node biopsy (SLNB). The resected sentinel lymph nodes were negative for malignancy, with an axillary lymphadenectomy not being performed. In the early post-operative period, the patient reported an axillary skin tension sensation, associated with a painful palpable cord. These are typical manifestations of axillary web syndrome (AWS), a poorly known axillary surgery complication, from both invasive and conservative interventions. By presenting this case we want to focus the attention on a pathological condition, for which its incidence may be underestimated by not including it in SLNB studies. It is important for nuclear medicine physicians to be aware of AWS as a more common complication than infection, seroma, or lymphoedema, and to discuss this possible event with the patient who is consenting to the procedure.

  13. Liver Biopsy for Histological Assessment: The Case in Favor

    PubMed Central

    Alswat, Khalid A.; Mumtaz, Khalid; Jafri, Wasim

    2010-01-01

    Liver biopsy (LB) is the gold standard method for assessment of liver histology. It provides valuable, otherwise unobtainable information, regarding the degree of fibrosis, parenchymal integrity, degree and pattern of inflammation, bile duct status and deposition of materials and minerals in the liver. This information provides immense help in the diagnosis and prognostication of a variety of liver diseases. With careful selection of patients, and performance of the procedure appropriately, the complications become exceptionally rare in current clinical practice. Furthermore, the limitations of sampling error and inter-/ intra-observer variability may be avoided by obtaining adequate tissue specimen and having it reviewed by an experienced liver pathologist. Current noninvasive tools are unqualified to replace LB in clinical practice in the face of specific limitations for each tool, compounded by a poorer performance towards the assessment of the degree of liver fibrosis, particularly for intermediate stages. PMID:20339188

  14. Axillary web syndrome following sentinel node biopsy for breast cancer.

    PubMed

    Nieves Maldonado, S M; Pubul Núñez, V; Argibay Vázquez, S; Macías Cortiñas, M; Ruibal Morell, Á

    2016-01-01

    A 49 year-old woman diagnosed with infiltrating lobular breast carcinoma, underwent a right mastectomy and sentinel node biopsy (SLNB). The resected sentinel lymph nodes were negative for malignancy, with an axillary lymphadenectomy not being performed. In the early post-operative period, the patient reported an axillary skin tension sensation, associated with a painful palpable cord. These are typical manifestations of axillary web syndrome (AWS), a poorly known axillary surgery complication, from both invasive and conservative interventions. By presenting this case we want to focus the attention on a pathological condition, for which its incidence may be underestimated by not including it in SLNB studies. It is important for nuclear medicine physicians to be aware of AWS as a more common complication than infection, seroma, or lymphoedema, and to discuss this possible event with the patient who is consenting to the procedure. PMID:27246290

  15. [3D computer-assisted ENT biopsies of the Iceman].

    PubMed

    Thumfart, W F; Freysinger, W; Gunkel, A R; Truppe, M J; Platzer, W

    1997-02-01

    The University of Innsbruck possesses a unique prehistoric, completely conserved 5300-year-old human cadaver. We report our experiences during which ENT specialists collected samples from various cavities inside the Iceman. Guidance of biopsy instruments was accomplished with computer-assisted navigation based on Interventional Video Tomography. This technology allows surgical guidance by interlinking currently available imaging modalities with live endoscopic video. The system operates without patient fixation and is practically free of external contact. Apart from sterility, special precautionary measures were necessary to avoid contamination with heavy metals or microorganisms. Visual inspection of the samples of mucosa from the nose, maxillary sinus and larynx revealed the typical patterns of a human cadaver without overt pathology.

  16. Diagnostic Concordance Among Pathologists Interpreting Breast Biopsy Specimens

    PubMed Central

    Elmore, Joann G.; Longton, Gary M.; Carney, Patricia A.; Geller, Berta M.; Onega, Tracy; Tosteson, Anna N. A.; Nelson, Heidi D.; Pepe, Margaret S.; Allison, Kimberly H.; Schnitt, Stuart J.; O’Malley, Frances P.; Weaver, Donald L.

    2015-01-01

    IMPORTANCE A breast pathology diagnosis provides the basis for clinical treatment and management decisions; however, its accuracy is inadequately understood. OBJECTIVES To quantify the magnitude of diagnostic disagreement among pathologists compared with a consensus panel reference diagnosis and to evaluate associated patient and pathologist characteristics. DESIGN, SETTING, AND PARTICIPANTS Study of pathologists who interpret breast biopsies in clinical practices in 8 US states. EXPOSURES Participants independently interpreted slides between November 2011 and May 2014 from test sets of 60 breast biopsies (240 total cases, 1 slide per case), including 23 cases of invasive breast cancer, 73 ductal carcinoma in situ (DCIS), 72 with atypical hyperplasia (atypia), and 72 benign cases without atypia. Participants were blinded to the interpretations of other study pathologists and consensus panel members. Among the 3 consensus panel members, unanimous agreement of their independent diagnoses was 75%, and concordance with the consensus-derived reference diagnoses was 90.3%. MAIN OUTCOMES AND MEASURES The proportions of diagnoses overinterpreted and underinterpreted relative to the consensus-derived reference diagnoses were assessed. RESULTS Sixty-five percent of invited, responding pathologists were eligible and consented to participate. Of these, 91% (N = 115) completed the study, providing 6900 individual case diagnoses. Compared with the consensus-derived reference diagnosis, the overall concordance rate of diagnostic interpretations of participating pathologists was 75.3% (95% CI, 73.4%–77.0%; 5194 of 6900 interpretations). Consensus ReferenceDiagnosis Pathologist Interpretation vs Consensus-Derived Reference Diagnosis, % (95% CI) No. ofInterpretations Overall ConcordanceRate OverinterpretationRate UnderinterpretationRate Benign without atypia 2070 87 (85–89) 13 (11–15) Atypia 2070 48 (44–52) 17 (15–21) 35 (31–39) DCIS 2097 84 (82–86) 3 (2–4) 13 (12

  17. MR-compatible biopsy needle with enhanced tip force sensing

    PubMed Central

    Elayaperumal, Santhi; Bae, Jung Hwa; Christensen, David; Cutkosky, Mark R.; Daniel, Bruce L.; Costa, Joannes M.; Black, Richard J.; Faridian, Fereydoun; Moslehi, Behzad

    2015-01-01

    We describe an instrumented biopsy needle that provides physicians the capability to sense interaction forces directly at the tip of the needle’s inner stylet. The sensors consist of optical fiber Bragg gratings (FBGs), and are unaffected by electromagnetic fields; hence the needle is suitable for MR-guided procedures. In comparison to previous instrumented needles that measure bending strains, the new design has additional sensors and a series of micro-machined holes at the tip. The holes increase strain sensitivity, especially to axial forces, without significantly reducing the stiffness or strength. A comparison of the dynamic forces measured with the new needle and those obtained using a force/torque sensor at the needle base shows that the enhanced tip sensitivity is particularly noticeable when there is significant friction along the needle sleeve. PMID:26509189

  18. Enzymic analysis of endomyocardial biopsy specimens from patients with cardiomyopathies.

    PubMed Central

    Peters, T J; Wells, G; Oakley, C M; Brooksby, I A; Jenkins, B S; Webb-Peploe, M M; Coltart, D J

    1977-01-01

    Myocardial biopsies have been obtained from patients with hypertrophic or congestive cardiomyopathies. Marker enzymes for the principal subcellular organelles of the myocardium were estimated using highly sensitive assay procedures. The results were compared with those obtained in tissue from patients with valvular heart disease with good or poor left ventricular function. Left ventricular myocardial tissue from patients with hypertrophic cardiomyopathy showed essentially normal levels of enzymic activities. In congestive cardiomyopathy, right ventricular tissue showed reduced levels of mitochondrial enzymes with increased levels of lactate dehydrogenase. Left ventricular tissue from patients with congestive cardiomyopathy showed reduced levels of mitochondrial and myofibril enzymes but high levels of lactate dehydrogenase. The reduced levels of myofibril Ca++-activated ATP in congestive cardiomyopathy is similar to that found in patients with impaired left ventricular function secondary to valvular disease. It is suggested that defective mitochondrial function is a characteristic feature of congestive cardiomyopathy and that the increased levels of lactate dehydrogenase reflect a compensatory response. PMID:564201

  19. Morphometric assessment of reflux oesophagitis in fibreoptic biopsy specimens.

    PubMed Central

    Jarvis, L R; Dent, J; Whitehead, R

    1985-01-01

    The oesophageal epithelium of patients with reflux oesophagitis has been studied by means of computer aided morphometry. Measurements of histological features were made on biopsies from six cases before and after treatment. The size and elongation of the nuclei and their variation, the number of nuclei per unit length or per unit sectioned area, and the size and number of nucleoli per nucleus were measured for two zones of the epithelium, the base layer and the intermediate layer, which were independent of section orientation. The measurements were analysed using discriminant analysis. Significant discrimination was found between the two groups. The most important parameters were the number of intermediate layer nuclei per sectioned square millimetre, the mean intermediate layer nuclear area, and the number of nuclei per millimetre of base epithelium. These parameters are consistent with increased cell turnover of the non-ulcerated epithelium before treatment. Images PMID:3968208

  20. Development of the optical biopsy system for small experimental animals

    NASA Astrophysics Data System (ADS)

    Sato, Hidetoshi; Hattori, Yusuke; Oshima, Yusuke; Komachi, Yuichi; Katagiri, Takashi; Asakura, Toru; Shimosegawa, Toru; Matsuura, Yuji; Miyagi, Mitsunobu; Kanai, Gen'ichi; Ura, Nobuo; Masutani, Koji; Tashiro, Hideo

    2006-02-01

    Development of the optical biopsy system for experimental small animals is in progress. A prototype of the system which consists of a miniaturized gastro endoscope unit and Raman probes has been completed by now. The system is developed to study a gastric cancer rat model. The endoscope is 2.5 mm in diameter and is equipped an imaging bundle fiber, illumination fibers, a channel and a mechanism to angle the probe head. The head of the Raman probe comes out through the channel and it is possible to aim the probe to the target watching on the monitor. The endoscope was inserted into the anaesthetized healthy rat under the breathing support. It was successfully observed inside of the stomach of the living rat and measured Raman spectra. The spectrum of blood vessels contains the strong contribution from lipids. The present results demonstrate high potential of the system in the in vivo Raman study using the rat model.