Science.gov

Sample records for 45-day safety screening

  1. 45-Day safety screening results for tank 241-U-102, push mode cores 143 and 144

    SciTech Connect

    Steen, F.H.

    1996-06-28

    This document is the 45-day report deliverable for tank 241-U-102 push mode core segments collected between April 16, 1996 and May 6, 1996 and received by the 222-S Laboratory between April 17, 1996 and May 8, 1996. The segments were subsampled and analyzed in accordance, with the Tank 241-U-102 Push Mode Core Sampling and analysis Plan (TSAP) (Hu, 1996) and the Safety Screening Data Quality Objective (DQO) (Dukelow, et al., 1995). The analytical results are included in Table 1. Attachment I is a cross reference to relate the tank farm identification numbers to the 222-S Laboratory LabCore sample numbers. The subsamples generated in the laboratory for analysis are identified in these diagrams with their sources shown. The diagram identifying the hydrostatic head fluid (HHF) blank is also included, Primary safety screening results and the raw data from Differential Scanning Calorimetry (DSC) and thermogravimetric analysis (TGA) analyses are included in this report. Two of the samples submitted for DSC analysis exceeded notification limits as stated in the Safety Screening DQO (Dukelow, et al., 1995). Cyanide analysis was requested on these samples and a Reactive System Screening Tool analysis was requested for the sample exhibiting the highest exothenn in accordance with the TSAP (Hu, 1996). The results for these analyses will be reported in a revision to this document.

  2. 45-Day safety screening for Tank 241-B-102 auger samples, riser 1

    SciTech Connect

    Bell, K.E.

    1994-12-01

    This is the 45-Day report for the fiscal year 1994 Tank 241-B-102 auger sampling characterization effort. Only one of the two planned auger samples was received by the 222-S Laboratory, however it was decided to begin the 45-day clock and issue a report based on receipt of the first auger sample. Included are copies of the differential scanning calorimetry (DSC) and thermogravimetric analysis (TGA) scans as requested. Also included is a copy of any immediate notification documentation, chain of custody forms, the hot cell work plan, extruded segment [auger] description sheets, and total alpha data. The TGA percent moisture results are below the safety criteria limit of 17% in a subsample taken approximately five minutes after extrusion and a second subsample taken from the lower half of the auger. Verbal and written notifications were made as prescribed. The DSC analysis of all subsamples indicates the presence of fraction exotherms, however the results are a factor of two or more below the notification limit of 523 Joules/gram (J/g). Total alpha results are all below the detection limit. In some cases, the tank characterization plan (TCP) accuracy and precision criteria are not met. If a re-run was not performed when a TCP quality control limit was not met, then reasons for not performing the re-run are provided.

  3. 45-Day safety screen results for tank 241-C-105, push mode, cores 72 and 76

    SciTech Connect

    Sasaki, L.M.

    1995-05-03

    This document is a report of the analytical results for samples collected between March 14 and March 22, 1995 from the radioactive wastes in Tank 241-C-105 at the Hanford Reservation. Core samples were collected from the solid wastes in the tank and underwent safety screening analyses including differential scanning calorimetry, thermogravimetric analysis, and total alpha analysis.

  4. 45-day safety screen results for tank 241-U-204, push mode, cores 81 and 82

    SciTech Connect

    Bell, K.E.

    1995-05-17

    This is the 45-Day report for the fiscal year 1995 tank 241-U-204 (U-204) push-mode characterization effort. Included are a summary of analytical results and copies of the differential scanning calorimetry (DSC) and thermogravimetric analysis (TGA) scans. Core samples 81 and 82 from tank U-204, obtained by the push-mode core sampling method, were received by the 222-S Laboratories. Each core consisted of only one segment. Both core samples and the field blank were extruded, subsampled, and analyzed in accordance with Reference 1. Drainable liquids and the field blank were analyzed at the segment level for energetics by DSC, percent water by TGA, and total organic carbon (TOC) by furnace oxidation. In addition, the presence or absence of any separable, presumably organic, layer in drainable liquid samples was noted and none was observed. The solids were analyzed directly at the half segment level for energetics by DSC, percent water by TGA, and TOC by persulfate oxidation. Total alpha activity was determined on fusion digestions of the sludge subsamples. No immediate notifications were necessary on samples from cores 81 or 82.

  5. 45-Day safety screen results and final report for Tank 241-SX-113, Auger samples 94-AUG-028 and 95-AUG-029

    SciTech Connect

    Sasaki, L.M.

    1995-06-22

    This document serves as the 45-day report deliverable for tank 241-SX-113 auger samples collected on May 9 and 10, 1995. The samples were extruded, and analyzed by the 222-S Laboratory. Laboratory procedures completed include: differential scanning calorimetry; thermogravimetric analysis; and total alpha analysis. This report incudes the primary safety screening results obtained from the analyses. As the final report, the following are also included: chains of custody; the extrusion logbook; sample preparation data; and total alpha analysis raw data.

  6. 45-Day safety screen results for Tank 241-U-201, push mode, cores 70, 73 and 74

    SciTech Connect

    Sathyanarayana, P.

    1995-05-04

    Three core samples, each having two segments, from Tank 241-U-201 (U-201) were received by the 222-S Laboratories. Safety screening analysis, such as differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), and total alpha activity were conducted on Core 70, Segment 1 and 2 and on Core 73, Segment 1 and 2. Core 74, Segment 1 and 2 were taken to test rotary bit in push mode sampling. No analysis was requested on Core 74, Segment 1 and 2. Analytical results for the TGA analyses for Core 70, Segment 1, Upper half solid sample was less than the safety screening notification limit of 17 percent water. Notification was made on April 27, 1995. No exotherm was associated with this sample. Analytical results are presented in Tables 1 to 4, with the applicable notification limits shaded.

  7. 45-day safety screen results and final report for Tank 241-C-203, Auger samples 95 AUG-020 and 95-AUG-021

    SciTech Connect

    Conner, J.M.

    1995-05-18

    This document serves as the 45-day report deliverable for the tank C-203 auger samples collected on April 5, 1995 (samples 95-AUG-20 and 95-AUG-021). As no secondary analyses were required and no other analyses have been requested, this document also serves as the final report for C-203 auger sampling. Each sample was received, extruded, and analyzed by the 222-S Laboratories in accordance with the Tank Characterization Plan (TCP) referenced below. Included in this report are the primary safety screening results (DSC, TGA, and alpha) and density results. The worklists and raw data are included in this report. Photographs of the auger samples were taken during extrusion and, although not included in this report, are available.

  8. 45-Day safety screen results for single shell tank 241-AP-106, liquid grab samples, riser 1, 30{degrees} and 150{degrees} in conjunction with evaporator campaign 95-1

    SciTech Connect

    Miller, G.L.

    1994-12-14

    This is the 45-Day report for the fiscal year 1995 safety screening characterization of three liquid grab samples from single shell tank 241-AP-106. The required analyses are differential scanning calorimetry (DSC), thermal gravimetric analysis (TGA) and appearance (APPR). No analytes exceeded the notification limits, therefore, secondary analyses (RSST, cyanide, and hot persulfate-total organic carbon) were not required. Summary data tables 2, 3 and 4 present the appearance, DSC and TGA data, respectively. Total alpha analyses are not included in this report, because it is not required for liquid grab samples.

  9. Tank 241-S-109, Cores 158 and 160, analytical results for the 45 day report

    SciTech Connect

    Fritts, L.L., Westinghouse Hanford

    1996-08-15

    This document is the 45-day laboratory report for tank 241-S-109. Push mode core segments were removed from risers 14 and 16 between June 21, 1996, and July 3, 1996. Segments were received and extruded at the 222-S Analytical Laboratory. Analyses were performed in accordance with the Tank 241-S-109 Push Mode Core Sampling and analysis Plan (TSAP) for this tank and the Safety Screening Data Quality Objective (DQO). None of the subsamples submitted for Total Alpha Activity (AT) analysis or Differential Scanning Calorimetry (DSC) exceeded the action limits as stated in the Safety Screening Data Quality Objective. Primary safety screening results are included in the data summary table. The raw data from DSC and TGA analyses are included in this report.

  10. Tank 241-AN-105, cores 152 and 153, analytical results for the 45 day report

    SciTech Connect

    Steen, F.H.

    1996-09-20

    This document is the 45-day laboratory report for tank 241-AN-105 push mode core segments collected between June 10, 1996 and June 28, 1996. The segments were subsampled and analyzed in accordance with the Tank 241-AN-105 Push Mode Core Sampling and analysis Plan (TSAP) and the Safety Screening Data Quality Objective (DQO). The analytical results are included in the data summary table. None of the samples submitted for Total Alpha Activity or Differential Scanning Calorimetry (DSC) analyses exceeded notification limits as stated in the Safety Screening DQO. Statistical evaluation on results by calculating the 95% upper confidence limit is not performed by the 222-S Laboratory and is not considered in this report. Primary safety screening results and the raw data from thermogravimetric analysis (TGA) and DSC analyses are included in this report.

  11. Tank 241-A-101, cores 154 and 156 analytical results for the 45 day report

    SciTech Connect

    Steen, F.H.

    1996-10-18

    This document is the 45-day laboratory report for tank 241 -A-101 push mode core segments collected between July II, 1996 and July 25, 1996. The segments were subsampled and analyzed in accordance with the Tank 241-A-101 Push Mode Core Sampling and Analysis Plan (TSAP) (Field, 1996) and the Safety Screening Data Quality Objective (DQO)(Dukelow, et al., 1995). The analytical results are included in the data summary table (Table 1). None of the samples submitted for Total Alpha Activity (AT) or Differential Scanning Calorimetry (DSC) analyses exceeded notification limits as stated in the Safety Screening DQO (Dukelow, et al., 1995). Statistical evaluation on results by calculating the 95% upper confidence limit is not performed by the 222-S Laboratory and is not considered in this report. Primary safety screening results and the raw data from thermogravimetric analysis (TGA) and DSC analyses are included in this report.

  12. 34 CFR 303.310 - Post-referral timeline (45 days).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 34 Education 2 2014-07-01 2013-07-01 true Post-referral timeline (45 days). 303.310 Section 303... Post-Referral Procedures-Screenings, Evaluations, and Assessments § 303.310 Post-referral timeline (45...) The lead agency must develop procedures to ensure that in the event the circumstances described in...

  13. 34 CFR 303.310 - Post-referral timeline (45 days).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 34 Education 2 2013-07-01 2013-07-01 false Post-referral timeline (45 days). 303.310 Section 303... Post-Referral Procedures-Screenings, Evaluations, and Assessments § 303.310 Post-referral timeline (45...) The lead agency must develop procedures to ensure that in the event the circumstances described in...

  14. 34 CFR 303.310 - Post-referral timeline (45 days).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 34 Education 2 2012-07-01 2012-07-01 false Post-referral timeline (45 days). 303.310 Section 303.310 Education Regulations of the Offices of the Department of Education (Continued) OFFICE OF SPECIAL... Post-Referral Procedures-Screenings, Evaluations, and Assessments § 303.310 Post-referral timeline...

  15. 25 CFR 293.11 - When will the 45-day timeline begin?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 25 Indians 1 2010-04-01 2010-04-01 false When will the 45-day timeline begin? 293.11 Section 293.11 Indians BUREAU OF INDIAN AFFAIRS, DEPARTMENT OF THE INTERIOR ECONOMIC ENTERPRISES CLASS III TRIBAL STATE GAMING COMPACT PROCESS § 293.11 When will the 45-day timeline begin? The 45-day timeline...

  16. 26 CFR 301.6323(d)-1 - 45-day period for making disbursements.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ....6323(d)-1 45-day period for making disbursements. (a) In general. Even though a notice of a lien... 26 Internal Revenue 18 2012-04-01 2012-04-01 false 45-day period for making disbursements. 301.6323(d)-1 Section 301.6323(d)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE...

  17. 26 CFR 301.6323(d)-1 - 45-day period for making disbursements.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ....6323(d)-1 45-day period for making disbursements. (a) In general. Even though a notice of a lien... 26 Internal Revenue 18 2011-04-01 2011-04-01 false 45-day period for making disbursements. 301.6323(d)-1 Section 301.6323(d)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE...

  18. 26 CFR 301.6323(d)-1 - 45-day period for making disbursements.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ....6323(d)-1 45-day period for making disbursements. (a) In general. Even though a notice of a lien... 26 Internal Revenue 18 2013-04-01 2013-04-01 false 45-day period for making disbursements. 301.6323(d)-1 Section 301.6323(d)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE...

  19. 26 CFR 301.6323(d)-1 - 45-day period for making disbursements.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ....6323(d)-1 45-day period for making disbursements. (a) In general. Even though a notice of a lien... 26 Internal Revenue 18 2014-04-01 2014-04-01 false 45-day period for making disbursements. 301.6323(d)-1 Section 301.6323(d)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE...

  20. Tank safety screening data quality objective. Revision 1

    SciTech Connect

    Hunt, J.W.

    1995-04-27

    The Tank Safety Screening Data Quality Objective (DQO) will be used to classify 149 single shell tanks and 28 double shell tanks containing high-level radioactive waste into safety categories for safety issues dealing with the presence of ferrocyanide, organics, flammable gases, and criticality. Decision rules used to classify a tank as ``safe`` or ``not safe`` are presented. Primary and secondary decision variables used for safety status classification are discussed. The number and type of samples required are presented. A tabular identification of each analyte to be measured to support the safety classification, the analytical method to be used, the type of sample, the decision threshold for each analyte that would, if violated, place the tank on the safety issue watch list, and the assumed (desired) analytical uncertainty are provided. This is a living document that should be evaluated for updates on a semiannual basis. Evaluation areas consist of: identification of tanks that have been added or deleted from the specific safety issue watch lists, changes in primary and secondary decision variables, changes in decision rules used for the safety status classification, and changes in analytical requirements. This document directly supports all safety issue specific DQOs and additional characterization DQO efforts associated with pretreatment and retrieval. Additionally, information obtained during implementation can assist in resolving assumptions for revised safety strategies, and in addition, obtaining information which will support the determination of error tolerances, confidence levels, and optimization schemes for later revised safety strategy documentation.

  1. Project Safety Net: A Health Screening Outreach and Assessment Program.

    ERIC Educational Resources Information Center

    Reuben, David B.; And Others

    1993-01-01

    Project Safety Net identifies low-income urban frail elderly and provides comprehensive geriatric assessment and referral. During 8-month period, 814 older persons were screened including high proportions who were widowed (51%) and who lived alone (66%). Effectiveness of program remains to be determined in randomized clinical trials. (Author/NB)

  2. Hazard screening application guide. Safety Analysis Report Update Program

    SciTech Connect

    1992-06-01

    The basic purpose of hazard screening is to group precesses, facilities, and proposed modifications according to the magnitude of their hazards so as to determine the need for and extent of follow on safety analysis. A hazard is defined as a material, energy source, or operation that has the potential to cause injury or illness in human beings. The purpose of this document is to give guidance and provide standard methods for performing hazard screening. Hazard screening is applied to new and existing facilities and processes as well as to proposed modifications to existing facilities and processes. The hazard screening process evaluates an identified hazards in terms of the effects on people, both on-site and off-site. The process uses bounding analyses with no credit given for mitigation of an accident with the exception of certain containers meeting DOT specifications. The process is restricted to human safety issues only. Environmental effects are addressed by the environmental program. Interfaces with environmental organizations will be established in order to share information.

  3. Final characterization and safety screen report of double shell tank 241-AP-105 for evaporator campaign 97-1

    SciTech Connect

    Miller, G.L.

    1997-01-20

    Evaporator candidate feed from tank 241-AP-105 (hereafter referred to as AP-105) was characterized for physical, inorganic, organic and radiochemical parameters by the 222-S Laboratory as directed by the Tank Sample and Analysis Plan (TSAP), References 1 through 4, and Engineering Change Notice, number 635332, Reference 5. This data package satisfies the requirement for a format IV, final report as described in Reference 1. This data package is also a follow-up to the 45-Day safety screen results for tank AP-105, Reference 8, which was issued on November 5, 1996, and is attached as Section II to this report. Preliminary data in the form of summary analytical tables were provided to the project in advance of this final report to enable early estimation of evaporator operational parameters, using the Predict modeling program. Analyses were performed at the 222-S Laboratory as defined and specified in the TSAP and the Laboratory's Quality Assurance P1an, References 6 and 7. Any deviations from the instructions documented in the TSAP are discussed in this narrative and are supported with additional documentation.

  4. Disrupted resting-state functional architecture of the brain after 45-day simulated microgravity

    PubMed Central

    Zhou, Yuan; Wang, Yun; Rao, Li-Lin; Liang, Zhu-Yuan; Chen, Xiao-Ping; Zheng, Dang; Tan, Cheng; Tian, Zhi-Qiang; Wang, Chun-Hui; Bai, Yan-Qiang; Chen, Shan-Guang; Li, Shu

    2014-01-01

    Long-term spaceflight induces both physiological and psychological changes in astronauts. To understand the neural mechanisms underlying these physiological and psychological changes, it is critical to investigate the effects of microgravity on the functional architecture of the brain. In this study, we used resting-state functional MRI (rs-fMRI) to study whether the functional architecture of the brain is altered after 45 days of −6° head-down tilt (HDT) bed rest, which is a reliable model for the simulation of microgravity. Sixteen healthy male volunteers underwent rs-fMRI scans before and after 45 days of −6° HDT bed rest. Specifically, we used a commonly employed graph-based measure of network organization, i.e., degree centrality (DC), to perform a full-brain exploration of the regions that were influenced by simulated microgravity. We subsequently examined the functional connectivities of these regions using a seed-based resting-state functional connectivity (RSFC) analysis. We found decreased DC in two regions, the left anterior insula (aINS) and the anterior part of the middle cingulate cortex (MCC; also called the dorsal anterior cingulate cortex in many studies), in the male volunteers after 45 days of −6° HDT bed rest. Furthermore, seed-based RSFC analyses revealed that a functional network anchored in the aINS and MCC was particularly influenced by simulated microgravity. These results provide evidence that simulated microgravity alters the resting-state functional architecture of the brains of males and suggest that the processing of salience information, which is primarily subserved by the aINS–MCC functional network, is particularly influenced by spaceflight. The current findings provide a new perspective for understanding the relationships between microgravity, cognitive function, autonomic neural function, and central neural activity. PMID:24926242

  5. Intraseasonal Tropical Storm Activity Prediction with the NCEP CFSv2 45-day Forecasts

    NASA Astrophysics Data System (ADS)

    Schemm, J. K. E.; Long, L. N.

    2015-12-01

    Global predictability of intraseasonal tropical storm (TS) activity is assessed using the 1999-2012 CFSv2 45-day hindcast suite and real-time predictions for 2014-2015. Weekly TS activities in the CFSv2 45-day forecasts were determined using the TS detection and tracking method devised by Carmago and Zebiak (2002). The forecast periods are divided into weekly intervals for Week 1 through Week 4. The TS activities in those intervals are compared to the observed activities based on the NHC HURDAT and JTWC Best Track datasets.The CFSv2 45-day hindcast suite is made of forecast runs initialized at 00, 06, 12 and 18Z every day during the 1999 - 2012 period. For predictability evaluation, forecast TS activities are analyzed based on 20-member ensemble forecasts comprised of 45-day runs made during the most recent 5 days prior to the verification period. The forecast TS activities are evaluated in terms of the number of storms, genesis locations and storm tracks during the weekly periods. The CFSv2 forecasts are shown to have a fair level of skill in predicting the anomalous number of storms over most of the seven ocean basins during the 1999-2012 active seasons. The average temporal correlation score for Week 1 forecasts is between 0.50-0.52 in the Eastern and Western North Pacific, the South Indian and South Pacific basins, while correlations drop to around 0.20 for Week 4 forecasts. The forecast track is also examined using density distribution maps and false alarm statistics compiled using the hindcast analyses with Heidke Skill Scores peaking at around 0.35. Real-time weekly TS activity predictions began in December 2013 using the climatological TS forecast statistics to make the model bias corrections in terms of the storm counts, track distribution and removal of false alarm storms. This operational implementation provides an objective tool for the CPC's Global Tropical Hazards Outlooks. Verification and evaluation of the 2014 and 2015 seasons will be discussed.

  6. Changes in the Diurnal Rhythms during a 45-Day Head-Down Bed Rest

    PubMed Central

    Liang, Xiaodi; Zhang, Lin; Wan, Yufeng; Yu, Xinyang; Guo, Yiming; Chen, Xiaoping; Tan, Cheng; Huang, Tianle; Shen, Hanjie; Chen, Xianyun; Li, Hongying; Lv, Ke; Sun, Fei; Chen, Shanguang; Guo, Jinhu

    2012-01-01

    In spaceflight human circadian rhythms and sleep patterns are likely subject to change, which consequently disturbs human physiology, cognitive abilities and performance efficiency. However, the influence of microgravity on sleep and circadian clock as well as the underlying mechanisms remain largely unknown. Placing volunteers in a prone position, whereby their heads rest at an angle of −6° below horizontal, mimics the microgravity environment in orbital flight. Such positioning is termed head-down bed rest (HDBR). In this work, we analysed the influence of a 45-day HDBR on physiological diurnal rhythms. We examined urinary electrolyte and hormone excretion, and the results show a dramatic elevation of cortisol levels during HDBR and recovery. Increased diuresis, melatonin and testosterone were observed at certain periods during HDBR. In addition, we investigated the changes in urination and defecation frequencies and found that the rhythmicity of urinary frequency during lights-off during and after HDBR was higher than control. The grouped defecation frequency data exhibits rhythmicity before and during HDBR but not after HDBR. Together, these data demonstrate that HDBR can alter a number of physiological processes associated with diurnal rhythms. PMID:23110150

  7. Changes in the diurnal rhythms during a 45-day head-down bed rest.

    PubMed

    Liang, Xiaodi; Zhang, Lin; Wan, Yufeng; Yu, Xinyang; Guo, Yiming; Chen, Xiaoping; Tan, Cheng; Huang, Tianle; Shen, Hanjie; Chen, Xianyun; Li, Hongying; Lv, Ke; Sun, Fei; Chen, Shanguang; Guo, Jinhu

    2012-01-01

    In spaceflight human circadian rhythms and sleep patterns are likely subject to change, which consequently disturbs human physiology, cognitive abilities and performance efficiency. However, the influence of microgravity on sleep and circadian clock as well as the underlying mechanisms remain largely unknown. Placing volunteers in a prone position, whereby their heads rest at an angle of -6° below horizontal, mimics the microgravity environment in orbital flight. Such positioning is termed head-down bed rest (HDBR). In this work, we analysed the influence of a 45-day HDBR on physiological diurnal rhythms. We examined urinary electrolyte and hormone excretion, and the results show a dramatic elevation of cortisol levels during HDBR and recovery. Increased diuresis, melatonin and testosterone were observed at certain periods during HDBR. In addition, we investigated the changes in urination and defecation frequencies and found that the rhythmicity of urinary frequency during lights-off during and after HDBR was higher than control. The grouped defecation frequency data exhibits rhythmicity before and during HDBR but not after HDBR. Together, these data demonstrate that HDBR can alter a number of physiological processes associated with diurnal rhythms. PMID:23110150

  8. Colorectal Cancer Screening at the Nexus of HIV, Minority Statuses, and Cultural Safety

    ERIC Educational Resources Information Center

    Ka'opua, Lana Sue I.; Diaz, Tressa P.; Park, Soon H.; Bowen, Talita; Patrick, Kevin; Tamang, Suresh; Braun, Kathryn L.

    2014-01-01

    Background: The incidence of non-AIDS-defining cancers has increased significantly among persons living with HIV (PLHIV). Screening education is recommended. Purpose: Social learning, minority stress, and cultural safety theories informed this pilot to assess the feasibility of a colorectal cancer screening intervention targeted to PLHIV, with…

  9. MRI safety: a report of current practice and advancements in patient preparation and screening.

    PubMed

    Weidman, Elizabeth K; Dean, Kathryn E; Rivera, William; Loftus, Michael L; Stokes, Thomas W; Min, Robert J

    2015-01-01

    MRI offers detailed diagnostic images without ionizing radiation; however, there are considerable safety concerns associated with high electromagnetic field strength. With increasing use of high and ultra high (7T) magnetic field strength, adequate patient preparation and screening for ferrous material is increasingly important. We review current safety standards for patient screening and preparation and how they are implemented at our institution. In addition, we describe a novel supplemental screening technique wherein the lights are dimmed in response to detected ferrous metal at the threshold of Zone IV. PMID:26422769

  10. Successful implementation of Lynch syndrome screening in a safety net institution.

    PubMed

    Kidambi, Trilokesh D; Lee, Robin; Terdiman, Jonathan P; Day, Lukejohn

    2016-07-01

    Lynch syndrome (LS) is the most common cause of hereditary colorectal cancer (CRC), and national guidelines recommend screening patients with CRC for LS. However, there is a paucity of data related to Lynch syndrome in the underserved population, in which unique issues of access, cultural beliefs regarding cancer, language barriers, immigration status, and financial restraints exist. We performed a descriptive, retrospective review of a selective LS screening protocol at an urban safety net hospital between 2009 and 2014 with the aim of describing the detected prevalence of LS as well as reporting the high quality and suboptimal screening rates. A total of 154 cases of CRC were identified over the 5-year period, of which 57 met selective LS screening criteria. Eleven patients had a positive screen, and three patients were diagnosed with LS, leading to an overall detected LS prevalence of 1.9 %. The rate of high quality screen was greater than 90 %, consistent with prior studies. Thus, we show that screening for LS in a safety net hospital can be successful in achieving high quality screening and provide an example for other public hospitals considering implementation of hereditary cancer screening. PMID:27372833

  11. Evaluating a Quality Improvement Program for Cervical Cancer Screening at an Urban Safety Net Clinic.

    PubMed

    Hills, Robin L; Kulbok, Pamela A; Clark, Myra

    2015-09-01

    This article evaluates a quality improvement program for improving guideline-consistent cervical cancer screening practices in an urban safety net clinic. Quality improvement initiatives that combine policy with practice are particularly timely in light of the alignment of cervical cancer screening guidelines released in 2012 by the most influential national organizations. A descriptive comparison design was employed using the Healthy People 2020 target of 93% screened according to guidelines. Provider-, patient-, and workflow-based strategies included (1) addition of a clinical decision support system, (2) provider educational outreach, (3) patient reminder letters, and (4) development of a clinic procedure manual. Through the application of an established quality measurement tool, three quality indicators were measured: screened according to evidence-based guidelines, not screened, and screened more frequently than recommended. Data from the sample (N = 1,032) were collected at baseline and 12 months postimplementation. Each quality indicator category was significant at follow-up. Patients screened according to guidelines nearly doubled while the number of underscreened patients was reduced by nearly half. Similarly, there was a threefold decrease in patients screened more frequently than recommended. Clinical administrators, quality improvement specialists, and health care providers in primary care settings can use the strategies implemented in this study as a starting point for continuous quality improvement initiatives for cervical cancer screening. PMID:26032371

  12. Colorectal Cancer Screening at the Nexus of HIV, Minority Statuses, and Cultural Safety

    PubMed Central

    Ka‘opua, Lana Sue I.; Diaz, Tressa P.; Park, Soon H.; Bowen, Talita; Patrick, Kevin; Tamang, Suresh; Braun, Kathryn L.

    2014-01-01

    Background The incidence of non-AIDS-defining cancers has increased significantly among persons living with HIV (PLHIV). Screening education is recommended. Purpose Social learning, minority stress, and cultural safety theories informed this pilot to assess the feasibility of a colorectal cancer screening intervention targeted to PLHIV, with additional tailoring for relevance to Native Hawaiians, a group with low participation in cancer screening. Method The targeted education included behavioral modeling and barriers counseling in a culturally safe environment. Using a 2-group, pre/posttest design, AIDS service organizations were randomized to culturally responsive or standard education. AIDS service organizations consumers recruited through venue-based promotions were the unit of analysis. Knowledge–attitudes–practices, fecal occult blood test screening completion, and intervention feasibility were measured. Results Treatment arm participants, regardless of ethnicity, adhered to fecal occult blood test instructions and achieved increases in screening knowledge, attitudes, and practices. Relevance and acceptability of the educational intervention were endorsed. Discussion The culturally responsive intervention was successful in this group of PLHIV. Additional tailoring may be needed to reach PLHIV who do not participate in organizational activities. Conclusion/Translation to Health Education Practice This culturally responsive intervention shows promise for efficacy testing in a broader PLHIV population. Constituent-involving strategies were central to its development and delivery. PMID:24653993

  13. Effects of 45-day -6° head-down bed rest on the time-based prospective memory

    NASA Astrophysics Data System (ADS)

    Chen, SiYi; Zhou, RenLai; Xiu, LiChao; Chen, ShanGuang; Chen, XiaoPing; Tan, Cheng

    2013-03-01

    The research explored the effects of 45-day -6° head-down bed rest (HDBR) simulation of microgravity on the time-based prospective memory (PM) with 16 males. The time-based prospective memory task was performed on the 2nd day before HDBR, on the 11th, 20th, 32nd, and 40th days during HDBR, and on the 8th day after HDBR, and subjects' anxiety and depression feelings were recorded simultaneously using Beck Anxiety Inventory (BAI) and Beck Depression Inventory (BDI). The results demonstrated that it showed decreased accuracy of PM responses and frequency of clock checks during and after bed rest; long term bed rest did not induce significant emotional changes. The deficit of prospective memory performance induced by long term HDBR may result from a lack of aerobic physical activity or changes in the prefrontal cortex, but it remains to be determined.

  14. Final characterization and safety screen report of double shell tank 241-AP-104 for 242-A evaporator, campaign 96-1

    SciTech Connect

    Miller, G.L.

    1996-04-19

    This data package satisfies the requirement for a format IV, final report. It is a follow-up to the 45-day safety screen report for tank AP-104. Evaporator candidate feed from tank 241-AP-104 (hereafter referred to as AP-104) was characterized for physical, inorganic, organic and radiochemical parameters by the Westinghouse Hanford Company, 222-S Laboratory, and by the Battelle Pacific Northwest National Laboratory (PNNL), Analytical Chemistry Laboratory (ACL) as directed by the Tank Sample and Analysis Plan (TSAP), References 1 through 4. Preliminary data in the form of summary analytical tables were provided to the project in advance of this final report to enable early estimation of evaporator operational parameters, using the Predict modeling program. Laboratory analyses at ACL Laboratory was performed according to the TSAP. Analyses were performed at the 222-S Laboratory as defined and specified in the TSAP and the Laboratory`s Quality Assurance Plan, References 5 and 6. Any deviations from the instructions documented in the TSAP are discussed in this narrative and are supported with additional documentation. SAMPLING The TSAP, section 2, provided sampling information for waste samples collected from tank AP-104. The bottle-on-a-string method was used to collect liquid grab samples from the tank. Each glass sample bottle was amber, precleaned, and contained approximately 100 milliliters. Each bottle was closed with a teflon seal cap (or teflon septum for volatile organic analysis samples). Field blank samples were prepared by placing deionized water into sampling bottles, lowering the unclosed bottles into the riser for a period of time, retrieving them from the riser, and then closing the bottles with the same types of caps used for the tank samples. None of the samples were preserved by acidification. Upon receipt, the sample bottles destined for organic analyses were placed in a refrigerator. No attempt was made during sampling to assure the complete

  15. No Time To Lose - High Throughput Screening To Assess Nanomaterial Safety

    PubMed Central

    Damoiseaux, R; George, S; Li, M; Pokhrel, S; Ji, Z; France, B; Xia, T; Suarez, E; Rallo, R; Mädler, L; Cohen, Y; Hoek, EMV; Nel, A

    2014-01-01

    Nanomaterials hold great promise for medical, technological and economical benefits. Knowledge concerning the toxicological properties of these novel materials is typically lacking. At the same time, it is becoming evident that some nanomaterials could have a toxic potential in humans and the environment. Animal based systems lack the needed capacity to cope with the abundance of novel nanomaterials being produced, and thus we have to employ in vitro methods with high throughput to manage the rush logistically and use high content readouts wherever needed in order to gain more depth of information. Towards this end, high throughput screening (HTS) and high content screening (HCS) approaches can be used to speed up the safety analysis on a scale that commensurate with the rate of expansion of new materials and new properties. The insights gained from HTS/HCS should aid in our understanding of the tenets of nanomaterial hazard at biological level as well as asset the development of safe-by-design approaches. This review aims to provide a comprehensive introduction to the HTS/HCS methodology employed for safety assessment of engineered nanomaterials (ENMs), including data analysis and prediction of potentially hazardous material properties. Given the current pace of nanomaterial development, HTS/HCS is a potentially effective means of keeping up with the rapid progress in this field – we have literally no time to lose. PMID:21301704

  16. Electromyography-based analysis of human upper limbs during 45-day head-down bed-rest

    NASA Astrophysics Data System (ADS)

    Fu, Anshuang; Wang, Chunhui; Qi, Hongzhi; Li, Fan; Wang, Zheng; He, Feng; Zhou, Peng; Chen, Shanguang; Ming, Dong

    2016-03-01

    Muscle deconditioning occurs in response to simulated or actual microgravity. In spaceflight, astronauts become monkey-like for mainly using their upper limbs to control the operating system and to complete corresponding tasks. The changes of upper limbs' athletic ability will directly affect astronauts' working performance. This study investigated the variation trend of surface electromyography (sEMG) during prolonged simulated microgravity. Eight healthy males participating in this study performed strict 45-day head-down bed-rest (HDBR). On the 5th day of pre-HDBR, and the 15th, the 30th and the 45th days of HDBR, the subjects performed maximum pushing task and maximum pulling task, and sEMG was collected from upper limbs synchronously. Each subject's maximum volunteer contractions of both the tasks during these days were compared, showing no significant change. However, changes were detected by sEMG-based analysis. It was found that integrated EMG, root mean square, mean frequency, fuzzy entropy of deltoid, and fuzzy entropy of triceps brachii changed significantly when comparing pre-HDBR with HDBR. The variation trend showed a recovery tendency after significant decline, which is inconsistent with the monotonic variation of lower limbs that was proved by previous research. These findings suggest that EMG changes in upper limbs during prolonged simulated microgravity, but has different variation trend from lower limbs.

  17. Pre-employment screening and health management for safety forces-methods and techniques.

    PubMed

    Mostardi, R A; Porterfield, J A; King, S; Urycki, S

    1990-01-01

    The purpose of this clinical report is to describe the process by which safety forces (police and fire) are tested prior to employment (pre-employment screening) and the periodic evaluations used to maintain such standards. The process began by testing 350 male police volunteers and developing a series of age stratified norms. These norms are used to compare incoming recruits such that candidates of a given age are compared to norms developed from police officers of the same age. The purposes of this report are to describe the clinical tests used in the pre-employment screening, to report the normative data and to describe the methods of comparing data obtained from applicants to the established norms. The proper management of high risk employees through pre-employment screening and intervention programs has been viewed as being necessary both for the individual employee in reducing injury and disease and for the municipality for cost saving purposes. J Orthop Sports Phys Ther 1990;11(9):398-401. PMID:18787271

  18. Screening for Chemical Contributions to Breast Cancer Risk: A Case Study for Chemical Safety Evaluation

    PubMed Central

    Ackerman, Janet M.; Dairkee, Shanaz H.; Fenton, Suzanne E.; Johnson, Dale; Navarro, Kathleen M.; Osborne, Gwendolyn; Rudel, Ruthann A.; Solomon, Gina M.; Zeise, Lauren; Janssen, Sarah

    2015-01-01

    Background Current approaches to chemical screening, prioritization, and assessment are being reenvisioned, driven by innovations in chemical safety testing, new chemical regulations, and demand for information on human and environmental impacts of chemicals. To conceptualize these changes through the lens of a prevalent disease, the Breast Cancer and Chemicals Policy project convened an interdisciplinary expert panel to investigate methods for identifying chemicals that may increase breast cancer risk. Methods Based on a review of current evidence, the panel identified key biological processes whose perturbation may alter breast cancer risk. We identified corresponding assays to develop the Hazard Identification Approach for Breast Carcinogens (HIA-BC), a method for detecting chemicals that may raise breast cancer risk. Finally, we conducted a literature-based pilot test of the HIA-BC. Results The HIA-BC identifies assays capable of detecting alterations to biological processes relevant to breast cancer, including cellular and molecular events, tissue changes, and factors that alter susceptibility. In the pilot test of the HIA-BC, chemicals associated with breast cancer all demonstrated genotoxic or endocrine activity, but not necessarily both. Significant data gaps persist. Conclusions This approach could inform the development of toxicity testing that targets mechanisms relevant to breast cancer, providing a basis for identifying safer chemicals. The study identified important end points not currently evaluated by federal testing programs, including altered mammary gland development, Her2 activation, progesterone receptor activity, prolactin effects, and aspects of estrogen receptor β activity. This approach could be extended to identify the biological processes and screening methods relevant for other common diseases. Citation Schwarzman MR, Ackerman JM, Dairkee SH, Fenton SE, Johnson D, Navarro KM, Osborne G, Rudel RA, Solomon GM, Zeise L, Janssen S. 2015

  19. A method for fast safety screening of explosives in terms of crystal packing and molecular stability.

    PubMed

    Hu, Xiaohua; Chen, Nana; Li, Weichen

    2016-07-01

    Safety prediction is crucial to the molecular design or the material design of explosives, and the predictions based on any single factor alone will cause much inaccuracy, leading to a desire for a method on multi-bases. The presented proposes an improved method for fast screening explosive safety by combining a crystal packing factor and a molecular one, that is, steric hindrance against shear slide in crystal and molecular stability, denoted by intermolecular friction symbol (IFS) and bond dissociation energy (BDE) of trigger linkage respectively. Employing this BDE-IFS combined method, we understand the impact sensitivities of 24 existing explosives, and predict those of two energetic-energetic cocrystals of the observed CL-20/BTF and the supposed HMX/TATB. As a result, a better understanding is implemented by the combined method relative to molecular stability alone, verifying its improvement of more accurate predictions and the feasibility of IFS to graphically reflect molecular stacking in crystals. Also, this work verifies that the explosive safety is strongly related with its crystal stacking, which determines steric hindrance and influences shear slide. PMID:27365051

  20. Health, Safety, and Environmental Screening and Ranking Frameworkfor Geologic CO2 Storage Site Selection

    SciTech Connect

    Oldenburg, Curtis M.

    2005-09-19

    This report describes a screening and ranking framework(SRF) developed to evaluate potential geologic carbon dioxide (CO2) storage sites on the basis of health, safety, and environmental (HSE) risk arising from possible CO2 leakage. The approach is based on the assumption that HSE risk due to CO2 leakage is dependent on three basic characteristics of a geologic CO2 storage site: (1) the potential for primary containment by the target formation; (2) the potential for secondary containment if the primary formation leaks; and (3) the potential for attenuation and dispersion of leaking CO2 if the primary formation leaks and secondary containment fails. The framework is implemented in a spreadsheet in which users enter numerical scores representing expert opinions or general information available from published materials along with estimates of uncertainty to evaluate the three basic characteristics in order to screen and rank candidate sites. Application of the framework to the Rio Visa Gas Field, Ventura Oil Field, and Mammoth Mountain demonstrates the approach. Refinements and extensions are possible through the use of more detailed data or model results in place of property proxies. Revisions and extensions to improve the approach are anticipated in the near future as it is used and tested by colleagues and collaborators.

  1. Health, Safety, and Environmental Screening and Ranking Frameworkfor Geologic CO2 Storage Site Selection

    SciTech Connect

    Oldenburg, Curtis M.

    2006-03-15

    This report describes a screening and ranking framework(SRF) developed to evaluate potential geologic carbon dioxide (CO2)storage sites on the basis of health, safety, and environmental (HSE)risk arising from possible CO2 leakage. The approach is based on theassumption that HSE risk due to CO2 leakage is dependent on three basiccharacteristics of a geologic CO2 storage site: (1) the potential forprimary containment by the target formation, (2) the potential forsecondary containment if the primary formation leaks, and (3) thepotential for attenuation and dispersion of leaking CO2 if the primaryformation leaks and secondary containment fails. The framework isimplemented in a spreadsheet in which users enter numerical scoresrepresenting expert opinions or general information available frompublished materials along with estimates of uncertainty to evaluate thethree basic characteristics in order to screen and rank candidate sites.Application of the framework to the Rio Vista Gas Field, Ventura OilField, and Mammoth Mountain demonstrates the approach. Refinements andextensions are possible through the use of more detailed data or modelresults in place of property proxies. Revisions and extensions to improvethe approach are anticipated in the near future as it is used and testedby colleagues and collaborators.

  2. High-throughput screening of drug-binding dynamics to HERG improves early drug safety assessment.

    PubMed

    Di Veroli, Giovanni Y; Davies, Mark R; Zhang, Henggui; Abi-Gerges, Najah; Boyett, Mark R

    2013-01-01

    The use of computational models to predict drug-induced changes in the action potential (AP) is a promising approach to reduce drug safety attrition but requires a better representation of more complex drug-target interactions to improve the quantitative prediction. The blockade of the human ether-a-go-go-related gene (HERG) channel is a major concern for QT prolongation and Torsade de Pointes risk. We aim to develop quantitative in-silico AP predictions based on a new electrophysiological protocol (suitable for high-throughput HERG screening) and mathematical modeling of ionic currents. Electrophysiological recordings using the IonWorks device were made from HERG channels stably expressed in Chinese hamster ovary cells. A new protocol that delineates inhibition over time was applied to assess dofetilide, cisapride, and almokalant effects. Dynamic effects displayed distinct profiles for these drugs compared with concentration-effects curves. Binding kinetics to specific states were identified using a new HERG Markov model. The model was then modified to represent the canine rapid delayed rectifier K(+) current at 37°C and carry out AP predictions. Predictions were compared with a simpler model based on conductance reduction and were found to be much closer to experimental data. Improved sensitivity to concentration and pacing frequency variables was obtained when including binding kinetics. Our new electrophysiological protocol is suitable for high-throughput screening and is able to distinguish drug-binding kinetics. The association of this protocol with our modeling approach indicates that quantitative predictions of AP modulation can be obtained, which is a significant improvement compared with traditional conductance reduction methods. PMID:23103500

  3. Comprehensive drug screening in blood for detecting abused drugs or drugs potentially hazardous for traffic safety.

    PubMed

    Lillsunde, P; Michelson, L; Forsstrom, T; Korte, T; Schultz, E; Ariniemi, K; Portman, M; Sihvonen, M L; Seppala, T

    1996-02-01

    A comprehensive drug screening procedure for detecting drugs in the blood samples of car drivers suspected of driving under the influence of drugs, is presented. Amphetamines, cannabinoids, opioids, cocaine and benzodiazepines were screened by an immunological EMIT ETS system after acetone precipitation. Gas chromatographic methods were used to screen and quantitate basic, neutral and acidic drugs. The free amino groups of basic drugs were derivatized with heptafluorobutyric anhydride. Analysis was performed by a dual channel gas chromatograph combined with a nitrogen phosphorus and an electron capture detector. Phenyltrimethylammonium hydroxide was used as a methylathing agent for acidic substances before analysis with a gas chromatograph connected to a nitrogen phosphorus detector. A gas chromatograph/mass spectrometry was used as a common confirmation method. Tetrahydrocannabinol was quantitated after bis(trimethylsilyl)trifluoroacetamide derivatization, opiates after pentafluoropropionic anhydride derivatization and benzoylecgonine after pentafluoropropionic anhydride and pentafluoropropanol derivatization. Excluding benzodiazepines, which were confirmed with a gas chromatograph connected to a nitrogen phosphorus and an electron capture detector, the other basic drugs as well as the acidic drugs were confirmed after the same derivatization procedures as in the screening methods. Alcohols were quantitated in triplicate by gas chromatography using three different kinds of columns. Although urine is the most important specimen for screening abused drugs, it has only limited use in forensic toxicology. The described system is most useful for analyzing a wide range of substances, including illicit drugs, benzodiazepines, barbiturates, antidepressants and phenothiazenes in forensic samples when urine is not available. PMID:8819994

  4. 77 FR 35745 - Highway Safety Programs; Conforming Products List of Screening Devices To Measure Alcohol in...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-14

    ...) published in the Federal Register on December 15, 2009 (74 FR 66398) for instruments that conform to the... FR 16956). DATES: Effective Date: June 14, 2012. FOR FURTHER INFORMATION CONTACT: For technical... for Screening Devices to Measure Alcohol in Bodily Fluids (59 FR 39382). These...

  5. Screening for transfusion transmissible infections using rapid diagnostic tests in Africa: a potential hazard to blood safety?

    PubMed

    Prugger, C; Laperche, S; Murphy, E L; Bloch, E M; Kaidarova, Z; Tafflet, M; Lefrère, J-J; Jouven, X

    2016-02-01

    Rapid diagnostic tests (RDTs) are routinely used in African blood centres. We analysed data from two cross-sectional studies representing 95 blood centres in 29 African countries. Standardized panels of sera containing varying concentrations of anti-human immunodeficiency virus (HIV) antibodies (Ab), hepatitis B virus antigen (HBsAg) and antihepatitis C virus (HCV) Ab were screened using routine operational testing procedures at the centres. Sensitivity of detection using RDTs was high for HIV Ab-positive samples, but low for intermediately HBsAg (51·5%) and HCV Ab (40·6%)-positive samples. These findings suggest that current RDT use in Africa could pose a hazard to blood safety. PMID:26646317

  6. Toxicology screen

    MedlinePlus

    Barbiturates - screen; Benzodiazepines - screen; Amphetamines - screen; Analgesics - screen; Antidepressants - screen; Narcotics - screen; Phenothiazines - screen; Drug abuse screen; Blood alcohol test

  7. Mediator's Assessment of Safety Issues and Concerns (MASIC): reliability and validity of a new intimate partner violence screen.

    PubMed

    Pokman, Viktoria; Rossi, Fernanda S; Holtzworth-Munroe, Amy; Applegate, Amy G; Beck, Connie J A; D'Onofrio, Brian M

    2014-10-01

    We investigated reliability and validity of the Mediator's Assessment of Safety Issues and Concerns (MASIC), a screening interview for intimate partner violence and abuse (IPV/A) in family mediation settings. Clients at three family mediation clinics in the United States and Australia (N = 391) provided reports of the other parent's IPV/A. Internal consistency of the total screen was excellent. A confirmatory factor analysis provided evidence that the MASIC assesses seven types of IPV/A: psychological abuse, coercive controlling behaviors, threats of severe violence, physical violence, severe physical violence, sexual violence, and stalking. Sex differences on differing types of violence victimization were generally consistent with previous research. Higher levels of victimization predicted self-reported consequences of abuse (e.g., fear, injuries). More abusive parties, as identified by their partners on the MASIC, had more Protective Orders and No Contact Orders and criminal convictions and crimes potentially related to IPV/A. Results provide initial evidence of the reliability and validity of the MASIC but more research is needed. PMID:24671737

  8. Screening probiotic strains for safety: Evaluation of virulence and antimicrobial susceptibility of enterococci from healthy Chinese infants.

    PubMed

    Zhang, Fen; Jiang, Meiling; Wan, Cuixiang; Chen, Xiaoyan; Chen, Xiaoyong; Tao, Xueying; Shah, Nagendra P; Wei, Hua

    2016-06-01

    The aim of this study was to evaluate the safety of enterococci isolated from Chinese infants and screen out potential probiotic candidates. One hundred eight strains were isolated from feces of 34 healthy infants, and 38 strains of Enterococcus spp. were categorized as follows: E. faecalis (22), E. faecium (10), E. hirae (3), E. durans (2), and E. casseliflavus (1). Of these, 72.7% of E. faecalis came from infants delivered by cesarean and 62.5% of E. faecium from infants delivered vaginally. For safety evaluation of strains, we determined presence of virulence genes; production of hemolysin, gelatinase, and biofilm; and antimicrobial susceptibility of enterococci. Six out of 14 virulence genes were detected with a distribution of gelE (26.3%), cylA (39.4%), esp (15.8%), efaA (63.2%), asa1 (50.0%), and ace (50.0%). In phenotype analysis, 36.8% of the strains exhibited positive hemolytic activity and 17.5% were positive for production of gelatinase. Results of antimicrobial susceptibility showed that different percentages of the strains were resistant to ciprofloxacin (5.2%), vancomycin (7.8%), rifampicin (10.5%), erythromycin (52.6%), and gentamycin (52.6%); remarkably, none of the strains were resistant to ampicillin or chloramphenicol. In total, 10 strains, including 6 E. faecium, which are free of virulence determinants and sensitive to common antimicrobial agents (e.g., ampicillin and vancomycin), were further assessed for their probiotic properties. All strains survived well in simulated gastric fluid and intestinal tract, with maximum reductions of 0.600 and 0.887 log cfu/mL, respectively. Six strains of E. faecium could resist 0.3 to 1.0% bile salt, of which E. faecium WEFA23 presented the highest growth (75.06%) at 1.0% bile salt. All strains showed bile salt hydrolase activity on glycodeoxycholic acid, but only 3 of E. faecium showed activity on taurodeoxycholic acid. These results deliver useful information on the safety of enterococci in infants in

  9. Characterization of human-induced pluripotent stem cell-derived cardiomyocytes: bioenergetics and utilization in safety screening.

    PubMed

    Rana, Payal; Anson, Blake; Engle, Sandra; Will, Yvonne

    2012-11-01

    Cardiotoxicity remains the number one reason for drug withdrawal from the market, and Food and Drug Administration issued black box warnings, thus demonstrating the need for more predictive preclinical safety screening, especially early in the drug discovery process when much chemical substrate is available. Whereas human-ether-a-go-go related gene screening has become routine to mitigate proarrhythmic risk, the development of in vitro assays predicting additional on- and off-target biochemical toxicities will benefit from cellular models exhibiting true cardiomyocyte characteristics such as native tissue-like mitochondrial activity. Human stem cell-derived tissue cells may provide such a model. This hypothesis was tested using a combination of flux analysis, gene and protein expression, and toxicity-profiling techniques to characterize mitochondrial function in induced pluripotent stem cell (iPSC) derived human cardiomyocytes in the presence of differing carbon sources over extended periods in cell culture. Functional analyses demonstrate that iPSC-derived cardiomyocytes are (1) capable of utilizing anaerobic or aerobic respiration depending upon the available carbon substrate and (2) bioenergetically closest to adult heart tissue cells when cultured in galactose or galactose supplemented with fatty acids. We utilized this model to test a variety of kinase inhibitors with known clinical cardiac liabilities for their potential toxicity toward these cells. We found that the kinase inhibitors showed a dose-dependent toxicity to iPSC cardiomyocytes grown in galactose and that oxygen consumption rates were significantly more affected than adenosine triphosphate production. Sorafenib was found to have the most effect, followed by sunitinib, dasatinib, imatinib, lapatinib, and nioltinib. PMID:22843568

  10. Safety.

    ERIC Educational Resources Information Center

    Education in Science, 1996

    1996-01-01

    Discusses safety issues in science, including: allergic reactions to peanuts used in experiments; explosions in lead/acid batteries; and inspection of pressure vessels, such as pressure cookers or model steam engines. (MKR)

  11. Understanding the digital divide in the clinical setting: the technology knowledge gap experienced by US safety net patients during teleretinal screening.

    PubMed

    George, Sheba; Moran, Erin; Fish, Allison; Ogunyemi, Lola

    2013-01-01

    Differential access to everyday technology and healthcare amongst safety net patients is associated with low technological and health literacies, respectively. These low rates of literacy produce a complex patient "knowledge gap" that influences the effectiveness of telehealth technologies. To understand this "knowledge gap", six focus groups (2 African-American and 4 Latino) were conducted with patients who received teleretinal screenings in U.S. urban safety-net settings. Findings indicate that patients' "knowledge gap" is primarily produced at three points: (1) when patients' preexisting personal barriers to care became exacerbated in the clinical setting; (2) through encounters with technology during screening; and (3) in doctor-patient follow-up. This "knowledge gap" can produce confusion and fear, potentially affecting patients' confidence in quality of care and limiting their disease management ability. In rethinking the digital divide to include the consequences of this knowledge gap faced by patients in the clinical setting, we suggest that patient education focus on both their disease and specific telehealth technologies deployed in care delivery. PMID:23920720

  12. Catalog of Canadian fitness screening protocols for public safety occupations that qualify as a bona fide occupational requirement.

    PubMed

    Gumieniak, Robert J; Jamnik, Veronica K; Gledhill, Norman

    2013-04-01

    The purpose of this paper was to provide succinct descriptions of prominent job-specific physical fitness protocols (JSPFPs) that were constructed to satisfy the legal obligations to qualify as a bona fide occupational requirement for physically demanding public safety occupations. The intent of a JSPFP is to determine whether an applicant or incumbent possesses the necessary physical capabilities to safely and efficiently perform the critical on-the-job tasks encountered in a physically demanding occupation. The JSPFP information summarized in this report is accessible in full detail in the public domain. Therefore, prospective JSPFP participants and fitness professionals who require the information to train participants can fully inform themselves about the specific protocol requirements and associated fitness training implications. PMID:22744418

  13. Using Interactive Web-Based Screening, Brief Intervention and Referral to Treatment in an Urban, Safety-Net HIV Clinic.

    PubMed

    Dawson Rose, Carol; Cuca, Yvette P; Kamitani, Emiko; Eng, Shannon; Zepf, Roland; Draughon, Jessica; Lum, Paula

    2015-06-01

    Substance use among people living with HIV is high, and screening, brief intervention, and referral to treatment (SBIRT) is an evidence-based approach to addressing the issue. We examined whether patients would participate in a technology-based SBIRT program in an urban HIV clinic. An SBIRT intervention was programmed into the clinic's web-based patient portal linked to their personal health record. We examined: demographic, health, HIV, and substance use characteristics of participants who completed the web-based intervention compared to those who did not. Fewer than half of the 96 participants assigned to the web-based SBIRT completed it (n = 39; 41 %). Participants who completed the web-based intervention had significantly higher amphetamine SSIS scores than those who did not complete the intervention. Participants whose substance use is more harmful may be more motivated to seek help from a variety of sources. In addition, it is important that technology-based approaches to behavioral interventions in clinics take into consideration feasibility, client knowledge, and comfort using technology. PMID:25963770

  14. Using Interactive Web-Based Screening, Brief Intervention and Referral to Treatment in an Urban, Safety-Net HIV Clinic

    PubMed Central

    Rose, Carol Dawson; Cuca, Yvette P.; Kamitani, Emiko; Eng, Shannon; Zepf, Roland; Draughon, Jessica; Lum, Paula

    2015-01-01

    Substance use among PLHIV is high, and screening, brief intervention, and referral to treatment (SBIRT) is an evidence-based approach to addressing the issue. We examined the acceptability of a technology-based SBIRT program in an urban HIV clinic. An SBIRT intervention was programmed into the clinic’s electronic personal health record. We examined: demographic, health, HIV, and substance use characteristics of participants who completed the web-based intervention compared to those who did not. Fewer than half of the 96 participants assigned to the web-based SBIRT completed it (n=39; 41%). Severity of tobacco and amphetamine use differed significantly between participants who did and did not complete the intervention (p=.03, .04 respectively). Participants with higher severity of tobacco and amphetamines were significantly more likely to utilize the web-based SBIRT. It is important for technology-based approaches to behavioral interventions in clinic take into consideration feasibility, client knowledge, and comfort using technology. PMID:25963770

  15. Human Pluripotent Stem Cell Based Developmental Toxicity Assays for Chemical Safety Screening and Systems Biology Data Generation.

    PubMed

    Shinde, Vaibhav; Klima, Stefanie; Sureshkumar, Perumal Srinivasan; Meganathan, Kesavan; Jagtap, Smita; Rempel, Eugen; Rahnenführer, Jörg; Hengstler, Jan Georg; Waldmann, Tanja; Hescheler, Jürgen; Leist, Marcel; Sachinidis, Agapios

    2015-01-01

    Efficient protocols to differentiate human pluripotent stem cells to various tissues in combination with -omics technologies opened up new horizons for in vitro toxicity testing of potential drugs. To provide a solid scientific basis for such assays, it will be important to gain quantitative information on the time course of development and on the underlying regulatory mechanisms by systems biology approaches. Two assays have therefore been tuned here for these requirements. In the UKK test system, human embryonic stem cells (hESC) (or other pluripotent cells) are left to spontaneously differentiate for 14 days in embryoid bodies, to allow generation of cells of all three germ layers. This system recapitulates key steps of early human embryonic development, and it can predict human-specific early embryonic toxicity/teratogenicity, if cells are exposed to chemicals during differentiation. The UKN1 test system is based on hESC differentiating to a population of neuroectodermal progenitor (NEP) cells for 6 days. This system recapitulates early neural development and predicts early developmental neurotoxicity and epigenetic changes triggered by chemicals. Both systems, in combination with transcriptome microarray studies, are suitable for identifying toxicity biomarkers. Moreover, they may be used in combination to generate input data for systems biology analysis. These test systems have advantages over the traditional toxicological studies requiring large amounts of animals. The test systems may contribute to a reduction of the costs for drug development and chemical safety evaluation. Their combination sheds light especially on compounds that may influence neurodevelopment specifically. PMID:26132533

  16. Screening for Intimate Partner Violence.

    PubMed

    Paterno, Mary T; Draughon, Jessica E

    2016-05-01

    Intimate partner violence (IPV) is a serious concern for women that is associated with significant adverse health effects. Routine screening for IPV is recommended, but there are many barriers to screening that have been identified by providers, including discomfort, lack of training, and not knowing how to respond to a positive screen. This article reviews IPV screening and appropriate techniques for responding to a positive screen. IPV screening best practices include using a systematic protocol, developing a screening script, using a validated screening tool, and considerations for privacy and mandatory reporting. Responding to a positive screen should include acknowledging the experience, asking if the woman desires help, offering support and referrals, encouraging safety planning, and completing additional assessments to determine level of danger and to identify any comorbidities. Using these techniques along with therapeutic communication may increase IPV identification and create an environment in which women feel empowered to get help. PMID:26990666

  17. Hand Safety

    MedlinePlus

    ... en gatillo See More... Hand Anatomy Hand Safety Fireworks Safety Lawnmower Safety Snowblower safety Pumpkin Carving Gardening ... en gatillo See More... Hand Anatomy Hand Safety Fireworks Safety Lawnmower Safety Snowblower safety Pumpkin Carving Gardening ...

  18. Hand Safety

    MedlinePlus

    ... Fireworks Safety Lawnmower Safety Snowblower safety Pumpkin Carving Gardening Safety Turkey Carving Removing a Ring Español Artritis ... Fireworks Safety Lawnmower Safety Snowblower safety Pumpkin Carving Gardening Safety Turkey Carving Removing a Ring Español Artritis ...

  19. Development of an Accessible Audio Computer-Assisted Self-Interview (A-CASI) to Screen for Abuse and Provide Safety Strategies for Women with Disabilities

    ERIC Educational Resources Information Center

    Oschwald, Mary; Renker, Paula; Hughes, Rosemary B.; Arthur, Anne; Powers, Laurie E.; Curry, Mary Ann

    2009-01-01

    To increase safety and minimize the risk of interpersonal violence, it is critical that women with disabilities and Deaf women have an opportunity to identify whether or not abuse is happening in their lives. Awareness and knowledge of what constitutes abusive behaviors is an essential first step in addressing interpersonal violence. This article…

  20. Airport Screening

    MedlinePlus

    ... 2011 Photo courtesy of Dan Paluska/Flickr Denver Airport Security Screening Introduction With air travel regaining popularity and increased secu- rity measures, airport security screening has become an area of interest for ...

  1. Health Screening

    MedlinePlus

    Screenings are tests that look for diseases before you have symptoms. Screening tests can find diseases early, when they're easier ... Overweight and obesity Prostate cancer in men Which tests you need depends on your age, your sex, ...

  2. MRSA Screening

    MedlinePlus

    ... be limited. Home Visit Global Sites Search Help? MRSA Screening Share this page: Was this page helpful? Formal name: Methicillin resistant Staphylococcus aureus Screening Related tests: Wound Culture At a Glance ...

  3. Antioxidant power as biochemical endpoint in bread for screening and early managing quality and toxicant-related safety anomalies in food production.

    PubMed

    Dragone, Roberto; Ermilov, Laura; Grasso, Gerardo; Maggioni, Silvia; Mantovani, Alberto; Frazzoli, Chiara

    2016-08-01

    Flaxseeds are both a food ingredient and a natural source of antioxidants (e.g. lignans, PUFAs) and pro-oxidant contaminants (e.g. cadmium): the variable mixture of anti- and pro-oxidant substances may impact on the redox homeostasis of flaxseed-enriched foods. The antioxidant power is studied here as biochemical activity of flaxseeds in white wheat bread and as endpoint for possible screening of anomalous variations of bioactive mixtures (antioxidants vs. prooxidants) in food matrices. A bioprobe assay based on the superoxide dismutase (SOD) enzyme (6 channels of the multiprobe bioelectronic platform BEST) was performed on white wheat bread with and without flaxseeds. Nine BEST channels were simultaneously used for validation and monitoring of measuring conditions (temperature, pH, conductivity). Findings were compared with quantitative analysis of antioxidants and pro-oxidant contaminants. Organic and aqueous extracts of both bread types were examined in parallel. The SOD-probe detected the difference in antioxidant power given by 10% flaxseed, thus supporting the use of antioxidant power detected by bioenzymatic screening as sensitive biochemical endpoint. Mixtures of bioactive molecules in foods generate biochemical activities that can be monitored as time-effective indicators of invariability, which is pivotal in the daily control of anomalies in food production and therefore in the protection of consumers' health. PMID:27174639

  4. Double screening

    NASA Astrophysics Data System (ADS)

    Gratia, Pierre; Hu, Wayne; Joyce, Austin; Ribeiro, Raquel H.

    2016-06-01

    Attempts to modify gravity in the infrared typically require a screening mechanism to ensure consistency with local tests of gravity. These screening mechanisms fit into three broad classes; we investigate theories which are capable of exhibiting more than one type of screening. Specifically, we focus on a simple model which exhibits both Vainshtein and kinetic screening. We point out that due to the two characteristic length scales in the problem, the type of screening that dominates depends on the mass of the sourcing object, allowing for different phenomenology at different scales. We consider embedding this double screening phenomenology in a broader cosmological scenario and show that the simplest examples that exhibit double screening are radiatively stable.

  5. Screening for Panic Disorder

    MedlinePlus

    ... Membership Journal & Multimedia Resources Awards Consumers Screening for Panic Disorder Main navigation FAQs Screen Yourself Screening for Depression ... Screening for Obsessive-Compulsive Disorder (OCD) Screening for Panic Disorder Screening for Posttraumatic Stress Disorder (PTSD) Screening for ...

  6. Genetic Screening

    PubMed Central

    Burke, Wylie; Tarini, Beth; Press, Nancy A.; Evans, James P.

    2011-01-01

    Current approaches to genetic screening include newborn screening to identify infants who would benefit from early treatment, reproductive genetic screening to assist reproductive decision making, and family history assessment to identify individuals who would benefit from additional prevention measures. Although the traditional goal of screening is to identify early disease or risk in order to implement preventive therapy, genetic screening has always included an atypical element—information relevant to reproductive decisions. New technologies offer increasingly comprehensive identification of genetic conditions and susceptibilities. Tests based on these technologies are generating a different approach to screening that seeks to inform individuals about all of their genetic traits and susceptibilities for purposes that incorporate rapid diagnosis, family planning, and expediting of research, as well as the traditional screening goal of improving prevention. Use of these tests in population screening will increase the challenges already encountered in genetic screening programs, including false-positive and ambiguous test results, overdiagnosis, and incidental findings. Whether this approach is desirable requires further empiric research, but it also requires careful deliberation on the part of all concerned, including genomic researchers, clinicians, public health officials, health care payers, and especially those who will be the recipients of this novel screening approach. PMID:21709145

  7. Integrating High-Dimensional Transcriptomics and Image Analysis Tools into Early Safety Screening: Proof of Concept for a New Early Drug Development Strategy.

    PubMed

    Verbist, Bie M P; Verheyen, Geert R; Vervoort, Liesbet; Crabbe, Marjolein; Beerens, Dominiek; Bosmans, Cindy; Jaensch, Steffen; Osselaer, Steven; Talloen, Willem; Van den Wyngaert, Ilse; Van Hecke, Geert; Wuyts, Dirk; Van Goethem, Freddy; Göhlmann, Hinrich W H

    2015-10-19

    During drug discovery and development, the early identification of adverse effects is expected to reduce costly late-stage failures of candidate drugs. As risk/safety assessment takes place rather late during the development process and due to the limited ability of animal models to predict the human situation, modern unbiased high-dimensional biology readouts are sought, such as molecular signatures predictive for in vivo response using high-throughput cell-based assays. In this theoretical proof of concept, we provide findings of an in-depth exploration of a single chemical core structure. Via transcriptional profiling, we identified a subset of close analogues that commonly downregulate multiple tubulin genes across cellular contexts, suggesting possible spindle poison effects. Confirmation via a qualified toxicity assay (in vitro micronucleus test) and the identification of a characteristic aggregate-formation phenotype via exploratory high-content imaging validated the initial findings. SAR analysis triggered the synthesis of a new set of compounds and allowed us to extend the series showing the genotoxic effect. We demonstrate the potential to flag toxicity issues by utilizing data from exploratory experiments that are typically generated for target evaluation purposes during early drug discovery. We share our thoughts on how this approach may be incorporated into drug development strategies. PMID:26313431

  8. Nuclear safety

    NASA Technical Reports Server (NTRS)

    Buden, D.

    1991-01-01

    Topics dealing with nuclear safety are addressed which include the following: general safety requirements; safety design requirements; terrestrial safety; SP-100 Flight System key safety requirements; potential mission accidents and hazards; key safety features; ground operations; launch operations; flight operations; disposal; safety concerns; licensing; the nuclear engine for rocket vehicle application (NERVA) design philosophy; the NERVA flight safety program; and the NERVA safety plan.

  9. Genetic screening

    PubMed Central

    Andermann, Anne; Blancquaert, Ingeborg

    2010-01-01

    Abstract OBJECTIVE To provide a primer for primary care professionals who are increasingly called upon to discuss the growing number of genetic screening services available and to help patients make informed decisions about whether to participate in genetic screening, how to interpret results, and which interventions are most appropriate. QUALITY OF EVIDENCE As part of a larger research program, a wide literature relating to genetic screening was reviewed. PubMed and Internet searches were conducted using broad search terms. Effort was also made to identify the gray literature. MAIN MESSAGE Genetic screening is a type of public health program that is systematically offered to a specified population of asymptomatic individuals with the aim of providing those identified as high risk with prevention, early treatment, or reproductive options. Ensuring an added benefit from screening, as compared with standard clinical care, and preventing unintended harms, such as undue anxiety or stigmatization, depends on the design and implementation of screening programs, including the recruitment methods, education and counseling provided, timing of screening, predictive value of tests, interventions available, and presence of oversight mechanisms and safeguards. There is therefore growing apprehension that economic interests might lead to a market-driven approach to introducing and expanding screening before program effectiveness, acceptability, and feasibility have been demonstrated. As with any medical intervention, there is a moral imperative for genetic screening to do more good than harm, not only from the perspective of individuals and families, but also for the target population and society as a whole. CONCLUSION Primary care professionals have an important role to play in helping their patients navigate the rapidly changing terrain of genetic screening services by informing them about the benefits and risks of new genetic and genomic technologies and empowering them to

  10. Get Screened

    MedlinePlus

    ... Get Ready 3 of 4 sections Take Action: Cost and Insurance What about cost? Depending on your insurance plan, you may be able to get screening tests at no cost to you. Most insurance plans, including Medicaid and ...

  11. TORCH screen

    MedlinePlus

    ... different infections in a newborn. TORCH stands for toxoplasmosis , rubella , cytomegalovirus, herpes simplex, and HIV, but it ... used to screen infants for infections such as toxoplasmosis, cytomegalovirus, herpes simplex, syphilis and others. These infections ...

  12. Developmental Screening

    MedlinePlus

    Learn More about Your Child’s Development: Developmental Monitoring and Screening Taking a first step, waving “bye-bye,” and pointing to something interesting are all developmental milestones, ...

  13. Hypertension screening

    NASA Technical Reports Server (NTRS)

    Foulke, J. M.

    1975-01-01

    An attempt was made to measure the response to an announcement of hypertension screening at the Goddard Space Center, to compare the results to those of previous statistics. Education and patient awareness of the problem were stressed.

  14. TORCH Screen

    MedlinePlus

    ... different infections in a newborn. TORCH stands for toxoplasmosis , rubella , cytomegalovirus, herpes simplex, and HIV, but it ... used to screen infants for infections such as toxoplasmosis, cytomegalovirus, herpes simplex, syphilis and others. These infections ...

  15. Newborn Screening

    MedlinePlus

    ... Pulse Oximetry Screening for CCHDs Sickle Cell Disease Laboratory SCID Quality Assurance Training and Resources For Lab Professionals Data and Reports Laboratory Reports National Birth Defects Prevention Network (NBDPN) Resources ...

  16. Screening for genital chlamydia infection

    PubMed Central

    Low, Nicola; Redmond, Shelagh; Uusküla, Anneli; van Bergen, Jan; Ward, Helen; Andersen, Berit; Götz, Hannelore

    2013-01-01

    This is the protocol for a review and there is no abstract. The objectives are as follows: To assess the effects and safety of chlamydia screening in pregnant and non-pregnant women and in men, compared with standard care, on chlamydia transmission and on complications of infection.

  17. Colon cancer screening

    MedlinePlus

    ... screening; Sigmoidoscopy - screening; Virtual colonoscopy - screening; Fecal immunochemical test; Stool DNA test; sDNA test ... death and complications caused by colorectal cancer. SCREENING TESTS There are several ways to screen for colon ...

  18. Screening for cancer

    SciTech Connect

    Miller, A.B.

    1985-01-01

    This book contains three sections: Fundamentals of Screening, Screening Tests, and Screening for Specific Cancer Sites. Each section consists of several chapters. Some of the chapter titles are: Principles of Screening and of the Evaluation of Screening Programs; Economic Aspects of Screening; Cervical Cytology; Screening Tests for Bladder Cancer; Fecal Occult Blood Testing; Screening for Cancer of the Cervix; Screening for Gastric Cancer; and Screening for Oral Cancer.

  19. Hearing Screening

    ERIC Educational Resources Information Center

    Johnson-Curiskis, Nanette

    2012-01-01

    Hearing levels are threatened by modern life--headsets for music, rock concerts, traffic noises, etc. It is crucial we know our hearing levels so that we can draw attention to potential problems. This exercise requires that students receive a hearing screening for their benefit as well as for making the connection of hearing to listening.

  20. Classroom Screening.

    ERIC Educational Resources Information Center

    Alpha Plus Corp., Piedmont, CA.

    This classroom screening device was developed by the Circle Preschool First Chance Project, a government-funded program to integrate handicapped children into regular classroom activities, for use in preschools, nursery schools, Head Start centers and other agencies working with young children. It is designed to give a gross measure of a child's…

  1. Vision Screening

    NASA Technical Reports Server (NTRS)

    1993-01-01

    The Visi Screen OSS-C, marketed by Vision Research Corporation, incorporates image processing technology originally developed by Marshall Space Flight Center. Its advantage in eye screening is speed. Because it requires no response from a subject, it can be used to detect eye problems in very young children. An electronic flash from a 35 millimeter camera sends light into a child's eyes, which is reflected back to the camera lens. The photorefractor then analyzes the retinal reflexes generated and produces an image of the child's eyes, which enables a trained observer to identify any defects. The device is used by pediatricians, day care centers and civic organizations that concentrate on children with special needs.

  2. Implementation Intentions and Colorectal Screening

    PubMed Central

    Greiner, K. Allen; Daley, Christine M.; Epp, Aaron; James, Aimee; Yeh, Hung-Wen; Geana, Mugur; Born, Wendi; Engelman, Kimberly K.; Shellhorn, Jeremy; Hester, Christina M.; LeMaster, Joseph; Buckles, Daniel; Ellerbeck, Edward F.

    2015-01-01

    Background Low-income and racial/ethnic minority populations experience disproportionate colorectal cancer (CRC) burden and poorer survival. Novel behavioral strategies are needed to improve screening rates in these groups. Purpose To test a theoretically based “implementation intentions” intervention for improving CRC screening among unscreened adults in urban safety-net clinics. Design Randomized controlled trial. Setting/participants Adults (N=470) aged ≥50 years, due for CRC screening, from urban safety-net clinics were recruited. Intervention The intervention (conducted in 2009–2011) was delivered via touchscreen computers that tailored informational messages to decisional stage and screening barriers. The computer then randomized participants to generic health information on diet and exercise (Comparison group) or “implementation intentions” questions and planning (Experimental group) specific to the CRC screening test chosen (fecal immunochemical test or colonoscopy). Main outcome measures The primary study outcome was completion of CRC screening at 26 weeks based on test reports (analysis conducted in 2012–2013). Results The study population had a mean age of 57 years, and was 42% non-Hispanic African American, 28% non-Hispanic white, and 27% Hispanic. Those receiving the implementation intentions–based intervention had higher odds (AOR=1.83, 95% CI=1.23, 2.73) of completing CRC screening than the Comparison group. Those with higher self-efficacy for screening (AOR=1.57, 95% CI=1.03, 2.39), history of asthma (AOR=2.20, 95% CI=1.26, 3.84), no history of diabetes (AOR=1.86, 95% CI=1.21, 2.86), and reporting they had never heard that “cutting on cancer” makes it spread (AOR=1.78, 95% CI=1.16, 2.72) were more likely to complete CRC screening. Conclusions The results of this study suggest that programs incorporating an implementation intentions approach can contribute to successful completion of CRC screening even among very low-income and

  3. Quadruple screen test

    MedlinePlus

    ... screen; Multiple marker screening; AFP plus; Triple screen test; AFP maternal; MSAFP; 4-marker screen ... This test is most often done between the 15th and 22nd weeks of the pregnancy. It is most accurate ...

  4. Summertime Safety

    MedlinePlus

    ... Violence & Safety Life Stages & Populations Travelers' Health Workplace Safety & Health Features Media Sign up for Features Get Email Updates ... Submit What's this? Submit Button Past Emails CDC Features Summertime Safety Recommend on Facebook Tweet Share Compartir The feature ...

  5. Drug Safety

    MedlinePlus

    ... over-the-counter drug. The FDA evaluates the safety of a drug by looking at Side effects ... clinical trials The FDA also monitors a drug's safety after approval. For you, drug safety means buying ...

  6. Safety Education.

    ERIC Educational Resources Information Center

    Daniels, James H.; And Others

    1980-01-01

    Five articles in this issue focus on safety education in agricultural laboratories. Topics discussed include teacher liability; elements of a safety instruction program; state and federal safety standards; ground fault current protection; and eye protection requirements and equipment. (SK)

  7. Newborn Screening

    PubMed Central

    Pitt, James J

    2010-01-01

    Early detection of many disorders, mainly inherited, is feasible with population-wide analysis of newborn dried blood spot samples. Phenylketonuria was the prototype disorder for newborn screening (NBS) and early dietary treatment has resulted in vastly improved outcomes for this disorder. Testing for primary hypothyroidism and cystic fibrosis (CF) was later added to NBS programs following the development of robust immunoassays and molecular testing. Current CF testing usually relies on a combined immunoreactive trypsin/mutation detection strategy. Multiplex testing for approximately 25 inborn errors of metabolism using tandem mass spectrometry is a relatively recent addition to NBS. The simultaneous introduction of many disorders has caused some re-evaluation of the traditional guidelines for NBS, because very rare disorders or disorders without good treatments can be included with minimal effort. NBS tests for many other disorders have been developed, but these are less uniformly applied or are currently considered developmental. This review focuses on Australasian NBS practices. PMID:20498829

  8. Screening for Specific Phobias

    MedlinePlus

    ... Screening for Posttraumatic Stress Disorder (PTSD) Screening for Social Anxiety Disorder Screening for Specific Phobias Screening for an Anxiety Disorder: Children Screening for an Anxiety Disorder: Family Member Self-Help Strategies: Webinars to Calm Anxious Minds "Triumph" E-News ...

  9. Groundwater Screen

    1993-11-09

    GWSCREEN was developed for assessment of the groundwater pathway from leaching of radioactive and non radioactive substances from surface or buried sources and release to percolation ponds. The code calculates the limiting soil concentration or effluent release concentration such that, after leaching and transport to the aquifer, regulatory contaminant levels in groundwater are not exceeded. The code uses a mass conservation approach to model three processes: Contaminant release from a source volume, contaminant transport inmore » the unsaturated zone, and contaminant transport in the saturated zone. The source model considers the sorptive properties and solubility of the contaminant. Transport in the unsaturated zone is described by a plug flow model. Transport in the saturated zone is calculated with a semi-analytical solution to the advection dispersion equation in groundwater. Concentration as a function of time at a user specified receptor point and maximum concentration averaged over the exposure interval are also calculated. In addition, the code calculates transport and impacts of radioactive progeny. Input to GWSCREEN is through one, free format ASCII file. This code was designed for assessment and screening of the groundwater pathway when field data is limited. It was not intended to be a predictive tool.« less

  10. An Alternative Field Method for Screening Soybean Genotypes for Resistance to Heterodera glycines

    PubMed Central

    Arantes, N. E.; Mauro, A. O.; Tihohood, D.

    1998-01-01

    The soybean cyst nematode (Heterodera glycines) has become an increasingly severe problem in soybean production areas in Brazil. The development and use of resistant cultivars is the most efficient method of minimizing losses due to this pathogen. Our objective was to test the efficiency of an alternative method for screening soybean genotypes for resistance to H. glycines in field plots. The alternative method was compared to the standard method of sowing the test genotypes in fields found to be infested during the previous crop season. In the alternative method, the test genotypes are sown in the furrow following the uprooting of 45-day-old infected plants. The alternative method resulted in twice the cyst population and fewer escapes, and more consistent results than the standard method. The major advantage of the alternative method is that it permits screening in a more homogeneous distribution of H. glycines in the soil. PMID:19274244

  11. Smart Screening System (S3) In Taconite

    SciTech Connect

    Daryoush Allaei

    2006-09-08

    The conventional screening machines used in processing plants have had undesirable high noise and vibration levels. They also have had unsatisfactorily low screening efficiency, high energy consumption, high maintenance cost, low productivity, and poor worker safety. These conventional vibrating machines have been used in almost every processing plant. Most of the current material separation technology uses heavy and inefficient electric motors with an unbalanced rotating mass to generate the shaking. In addition to being excessively noisy, inefficient, and high-maintenance, these vibrating machines are often the bottleneck in the entire process. Furthermore, these motors, along with the vibrating machines and supporting structure, shake other machines and structures in the vicinity. The latter increases maintenance costs while reducing worker health and safety. The conventional vibrating fine screens at taconite processing plants have had the same problems as those listed above. This has resulted in lower screening efficiency, higher energy and maintenance cost, and lower productivity and workers safety concerns. The focus of this work is on the design of a high performance screening machine suitable for taconite processing plants. SmartScreens{trademark} technology uses miniaturized motors, based on smart materials, to generate the shaking. The underlying technologies are Energy Flow Control{trademark} and Vibration Control by Confinement{trademark}. These concepts are used to direct energy flow and confine energy efficiently and effectively to the screen function. The SmartScreens{trademark} technology addresses problems related to noise and vibration, screening efficiency, productivity, and maintenance cost and worker safety. Successful development of SmartScreens{trademark} technology will bring drastic changes to the screening and physical separation industry. The final designs for key components of the SmartScreens{trademark} have been developed. The key

  12. Health Screenings and Immunizations

    MedlinePlus

    ... your primary doctor. Blood Tests – A Common Screening Method (Source: National Heart, Lung, and Blood Institute) Click ... tests, see What Are Blood Tests? Other Screening Methods Doctors can't screen for all diseases and ...

  13. Screen time and children

    MedlinePlus

    "Screen time" is a term used for activities done in front of a screen, such as watching TV, working on a computer, or playing video games. Screen time is sedentary activity, meaning you are being physically ...

  14. What Is Carrier Screening?

    MedlinePlus

    ... you want to learn. Search form Search Carrier screening You are here Home Testing & Services Testing for ... help you make the decision. What Is Carrier Screening? Carrier screening checks if a person is a " ...

  15. RBC Antibody Screen

    MedlinePlus

    ... be limited. Home Visit Global Sites Search Help? RBC Antibody Screen Share this page: Was this page ... Screen Related tests: Direct Antiglobulin Test ; Blood Typing ; RBC Antibody Identification ; Type and Screen; Crossmatch All content ...

  16. Putting the Screen in Screening

    PubMed Central

    Harris, Sion Kim; Knight, John R.

    2014-01-01

    Alcohol is strongly linked to the leading causes of adolescent and adult mortality and health problems, making medical settings such as primary care and emergency departments important venues for addressing alcohol use. Extensive research evidence supports the effectiveness of alcohol screening and brief interventions (SBIs) in medical settings, but this valuable strategy remains underused, with medical staff citing lack of time and training as major implementation barriers. Technology-based tools may offer a way to improve efficiency and quality of SBI delivery in such settings. This review describes the latest research examining the feasibility and efficacy of computer- or other technology-based alcohol SBI tools in medical settings, as they relate to the following three patient populations: adults (18 years or older); pregnant women; and adolescents (17 years or younger). The small but growing evidence base generally shows strong feasibility and acceptability of technology-based SBI in medical settings. However, evidence for effectiveness in changing alcohol use is limited in this young field. PMID:26259001

  17. Smart Screening System (S3) In Taconite Processing

    SciTech Connect

    Daryoush Allaei; Asim Syed Mohammed; David Tarnowski

    2003-03-01

    Initial assessment of vibrating fine screens at a taconite processing plant in Mountain Iron Minnesota showed undesirable high noise and vibration levels. This has resulted in lower screening efficiency, higher energy and maintenance cost, and lower productivity and workers safety concerns. Current material separation technology uses heavy electric motors with an unbalance rotating mass to generate the shaking. These motors along with the screens and supporting structure shake other machines and structure in the vicinity of the screens. SmartScreens{trademark} technology, based on smart materials, uses miniaturized motors to generate shaking. This technology, based on Energy Flow Control{trademark} and Vibration Control by Confinement{trademark}, can efficiently and effectively direct the energy flow and confine it to the screens. The SmartScreens{trademark} technology addresses problems related to noise and vibration, screening efficiency, productivity, maintenance cost, and worker safety. Successful development of SmartScreens{trademark} technology will bring drastic change to the screening and physical separation industry. The conceptual designs for SmartScreens{trademark} resonators have been developed. These resonators will be utilized to amplify motion generated by smart motors. Resonator designs are down selected based on the final system requirement and vibration characteristics. The most promising resonator designs are incorporated in the full system model and are analyzed through experimental testing and analysis. After a detailed review, one or two of these resonator systems will be used in the development of SmartScreens{trademark}.

  18. Vaccine Safety

    MedlinePlus

    ... During Pregnancy Frequently Asked Questions about Vaccine Recalls Historical Vaccine Safety Concerns FAQs about GBS and Menactra ... CISA Resources for Healthcare Professionals Evaluation Current Studies Historical Background 2001-12 Publications Technical Reports Vaccine Safety ...

  19. Safety Handbook.

    ERIC Educational Resources Information Center

    Montgomery County Public Schools, Rockville, MD.

    Safety policies, procedures, and related information are presented in this manual to assist school personnel in a continuing program of accident prevention. Chapter 1 discusses safety education and accident prevention in general. Chapter 2 covers traffic regulations relating to school safety patrols, school bus transportation, bicycles, and…

  20. Defining responsibility for screening.

    PubMed

    Sifri, R; Wender, R

    1999-10-01

    Patients commonly receive medical care from multiple providers and confusion as to who is responsible for cancer screening undoubtedly contributes to inadequate recommendations. Effective screening requires successful implementation of a series of steps that begin with the initial discussion of a screening test and proceed through obtaining results and instituting appropriate follow-up. Clear definition of generalist and specialist physician roles are necessary to optimally screen the public. This article explores the differences in how generalists and specialists approach screening, describes models of care that facilitate shared responsibility for screening, and suggests strategies on how to improve communication between physicians to maximize screening performance. PMID:10452930

  1. LANL seismic screening method for existing buildings

    SciTech Connect

    Dickson, S.L.; Feller, K.C.; Fritz de la Orta, G.O.

    1997-01-01

    The purpose of the Los Alamos National Laboratory (LANL) Seismic Screening Method is to provide a comprehensive, rational, and inexpensive method for evaluating the relative seismic integrity of a large building inventory using substantial life-safety as the minimum goal. The substantial life-safety goal is deemed to be satisfied if the extent of structural damage or nonstructural component damage does not pose a significant risk to human life. The screening is limited to Performance Category (PC) -0, -1, and -2 buildings and structures. Because of their higher performance objectives, PC-3 and PC-4 buildings automatically fail the LANL Seismic Screening Method and will be subject to a more detailed seismic analysis. The Laboratory has also designated that PC-0, PC-1, and PC-2 unreinforced masonry bearing wall and masonry infill shear wall buildings fail the LANL Seismic Screening Method because of their historically poor seismic performance or complex behavior. These building types are also recommended for a more detailed seismic analysis. The results of the LANL Seismic Screening Method are expressed in terms of separate scores for potential configuration or physical hazards (Phase One) and calculated capacity/demand ratios (Phase Two). This two-phase method allows the user to quickly identify buildings that have adequate seismic characteristics and structural capacity and screen them out from further evaluation. The resulting scores also provide a ranking of those buildings found to be inadequate. Thus, buildings not passing the screening can be rationally prioritized for further evaluation. For the purpose of complying with Executive Order 12941, the buildings failing the LANL Seismic Screening Method are deemed to have seismic deficiencies, and cost estimates for mitigation must be prepared. Mitigation techniques and cost-estimate guidelines are not included in the LANL Seismic Screening Method.

  2. Plasma Screen Floating Mount

    DOEpatents

    Eakle, Robert F.; Pak, Donald J.

    2004-10-26

    A mounting system for a flat display screen, particularly a plasma display screen, suspends the screen separately in each of the x-, y- and z-directions. A series of frames located by linear bearings and isolated by springs and dampers allows separate controlled movement in each axis. The system enables the use of relatively larger display screens in vehicles in which plasma screen are subject to damage from vibration.

  3. Risks of Breast Cancer Screening

    MedlinePlus

    ... of Breast & Gynecologic Cancers Breast Cancer Screening Research Breast Cancer Screening (PDQ®)–Patient Version What is screening? Go ... cancer screening: Cancer Screening Overview General Information About Breast Cancer Key Points Breast cancer is a disease in ...

  4. National Safety Council

    MedlinePlus

    ... Introduction Safety Management Systems Workplace Safety Consulting Employee Perception Surveys Research Journey to Safety Excellence Join the ... Safety Safety Management Systems Workplace Safety Consulting Employee Perception Surveys Research Journey to Safety Excellence Join the ...

  5. Safety Systems

    ERIC Educational Resources Information Center

    Halligan, Tom

    2009-01-01

    Colleges across the country are rising to the task by implementing safety programs, response strategies, and technologies intended to create a secure environment for teachers and students. Whether it is preparing and responding to a natural disaster, health emergency, or act of violence, more schools are making campus safety a top priority. At…

  6. Solidifying Safety

    NASA Technical Reports Server (NTRS)

    Covault, Craig

    2003-01-01

    Contents include the following: 1. Solidifying Safety: NASA s new safety organization spools up, as the 1SS program grapples with long-term risk. 2. Earth to Orbit O'Keefe telling skeptical lawmakers Orbital Space Plan (OSP) will cover exploration vision. China's rapid pace.

  7. Safety First

    ERIC Educational Resources Information Center

    Taft, Darryl

    2011-01-01

    Ned Miller does not take security lightly. As director of campus safety and emergency management at the Des Moines Area Community College (DMACC), any threat requires serious consideration. As community college administrators adopt a more proactive approach to campus safety, many institutions are experimenting with emerging technologies, including…

  8. Screening for Prostate Cancer

    MedlinePlus

    ... of Internal Medicine Summaries for Patients Screening for Prostate Cancer: A Guidance Statement From the Clinical Guidelines Committee ... Physicians The full report is titled “Screening for Prostate Cancer: A Guidance Statement From the Clinical Guidelines Committee ...

  9. Prostate cancer screenings

    MedlinePlus

    ... this page: //medlineplus.gov/ency/patientinstructions/000846.htm Prostate cancer screenings To use the sharing features on this ... present it is not clear if screening for prostate cancer is helpful for most men. For this reason, ...

  10. Stomach (Gastric) Cancer Screening

    MedlinePlus

    ... Treatment Stomach Cancer Prevention Stomach Cancer Screening Research Stomach (Gastric) Cancer Screening (PDQ®)–Patient Version What is ... These are called diagnostic tests . General Information About Stomach (Gastric) Cancer Key Points Stomach cancer is a ...

  11. Screening for Gestational Diabetes

    MedlinePlus

    ... Task Force learned about the potential benefits and harms of screening for gestational diabetes: (1) All women ... not enough evidence to judge the benefits and harms of screening women before 24 weeks of pregnancy. ...

  12. Hearing Loss: Screening Newborns

    MedlinePlus

    ... of this page please turn JavaScript on. Feature: Hearing Loss Screening Newborns Past Issues / Spring 2015 Table of ... of newborns in the U.S. are screened for hearing loss before they leave the hospital. Research improves the ...

  13. Video Screen Capture Basics

    ERIC Educational Resources Information Center

    Dunbar, Laura

    2014-01-01

    This article is an introduction to video screen capture. Basic information of two software programs, QuickTime for Mac and BlueBerry Flashback Express for PC, are also discussed. Practical applications for video screen capture are given.

  14. Screening for Breast Problems

    MedlinePlus

    f AQ FREQUENTLY ASKED QUESTIONS FAQ178 GYNECOLOGIC PROBLEMS Mammography and Other Screening Tests for Breast Problems • What ... used to screen for breast problems? • What is mammography? • Why is mammography done? • When should I start ...

  15. Breast cancer screenings

    MedlinePlus

    ... this page: //medlineplus.gov/ency/patientinstructions/000837.htm Breast cancer screenings To use the sharing features on this page, please enable JavaScript. Breast cancer screenings can help find breast cancer early, before ...

  16. Health Screenings at School

    MedlinePlus

    ... Listen Español Text Size Email Print Share Health Screenings at School Page Content Article Body In most ... child's ability to learn. In some states these screening tests are mandated by law and may also ...

  17. Human Papillomavirus (HPV) Screening

    MedlinePlus

    ... Diseases HPV-Associated Cancers Gynecologic Cancers Redirect CDC - Screening Recommend on Facebook Tweet Share Compartir You are being redirected to the HPV Cancer Screening page. Please update your bookmarks to the link ...

  18. Screening Tests and Vaccines

    MedlinePlus

    ... Contact Us Text size | Print | Screening Tests and Vaccines This information in Spanish ( en español ) Getting important screening tests and vaccines can save your life. Check this section of ...

  19. Stretching Screens and Imaginations.

    ERIC Educational Resources Information Center

    Douthwaite, Shelaugh

    1983-01-01

    Secondary students utilize a simplified technique to make silk screen prints, which can be printed onto T-shirts. The only materials needed from art suppliers are a few squeegees and a few yards of polyester screen mesh. (RM)

  20. Cervical Cancer Screening

    MedlinePlus

    ... Cancer found early may be easier to treat. Cervical cancer screening is usually part of a woman's health ... may do more tests, such as a biopsy. Cervical cancer screening has risks. The results can sometimes be ...

  1. Oral Cancer Screening

    MedlinePlus

    ... Prevention Oral Cavity and Oropharyngeal Cancer Screening Research Oral Cavity and Oropharyngeal Cancer Screening (PDQ®)–Patient Version What ... These are called diagnostic tests . General Information About Oral Cavity and Oropharyngeal Cancer Key Points Oral cavity and ...

  2. Colon cancer screening

    MedlinePlus

    ... screening; Virtual colonoscopy - screening; Fecal immunochemical test; Stool DNA test; sDNA test ... called the fecal immunochemical test (FIT) and stool DNA test (sDNA). Sigmoidoscopy : This test uses a small ...

  3. Focus screen optimization.

    PubMed

    Plummer, W T

    1975-11-01

    Ground glass used for camera focus screens often has far from optimum diffusion properties. An analysis of the function of the focus screen shows that a screen with random (Gaussian) diffusion properties can be constructed with both brightness and focus efficiencies above 84%. These considerations have led to the design of an unusually bright and effective focus screen for the Polaroid SX-70 Land camera. PMID:20155099

  4. Screening Tests for Women

    MedlinePlus

    ... questions you have. Make sure to ask about: Alcohol use Depression Weight Screening tests Screening tests Screening tests Ages ... for high cholesterol, and ways to improve cholesterol levels through lifestyle changes. ... Sheets - Alcohol Use and Health - This fact sheet talks about ...

  5. Cancer Screening: How Do Screening Tests Become Standard Tests?

    MedlinePlus

    ... cancer symptoms. There are different kinds of screening tests. Screening tests include the following: Physical exam and ... are linked to some types of cancer. Screening tests have risks. Not all screening tests are helpful ...

  6. Software safety

    NASA Technical Reports Server (NTRS)

    Leveson, Nancy

    1987-01-01

    Software safety and its relationship to other qualities are discussed. It is shown that standard reliability and fault tolerance techniques will not solve the safety problem for the present. A new attitude requires: looking at what you do NOT want software to do along with what you want it to do; and assuming things will go wrong. New procedures and changes to entire software development process are necessary: special software safety analysis techniques are needed; and design techniques, especially eliminating complexity, can be very helpful.

  7. Screening for colorectal cancer.

    PubMed

    He, Jin; Efron, Jonathan E

    2011-01-01

    March is national colorectal cancer awareness month. It is estimated that as many as 60% of colorectal cancer deaths could be prevented if all men and women aged 50 years or older were screened routinely. In 2000, Katie Couric's televised colonoscopy led to a 20% increase in screening colonoscopies across America, a stunning rise called the "Katie Couric Effect". This event demonstrated how celebrity endorsement affects health behavior. Currently, discussion is ongoing about the optimal strategy for CRC screening, particularly the costs of screening colonoscopy. The current CRC screening guidelines are summarized in Table 2. Debates over the optimum CRC screening test continue in the face of evidence that 22 million Americans aged 50 to 75 years are not screened for CRC by any modality and 25,000 of those lives may have been saved if they had been screened for CRC. It is clear that improving screening rates and reducing disparities in underscreened communities and population subgroups could further reduce colorectal cancer morbidity and mortality. National Institutes of Health consensus identified the following priority areas to enhance the use and quality of colorectal cancer screening: Eliminate financial barriers to colorectal cancer screening and appropriate follow-up of positive results of colorectal cancer screening. Develop systems to ensure the high quality of colorectal cancer screening programs. Conduct studies to determine the comparative effectiveness of the various colorectal cancer screening methods in usual practice settings. Encouraging population adherence to screening tests and allowing patients to select the tests they prefer may do more good (as long as they choose something) than whatever procedure is chosen by the medical profession as the preferred test. PMID:21954677

  8. Safety Tips.

    ERIC Educational Resources Information Center

    Nagel, Miriam C., Ed.

    1984-01-01

    Outlines a cooperative effort in Iowa to eliminate dangerous or unwanted chemicals from school science storerooms. Also reviews the Council of State Science Supervisor's safety program and discusses how to prevent cuts and punctures from jagged glass tubing. (JN)

  9. Food Safety

    MedlinePlus

    ... are four basic steps to food safety at home: Clean - always wash your fruits and vegetables, hands, counters, and cooking utensils. Separate - keep raw foods to themselves. Germs can spread from one food ...

  10. Lung Cancer Screening Update.

    PubMed

    Ruchalski, Kathleen L; Brown, Kathleen

    2016-07-01

    Since the release of the US Preventive Services Task Force and Centers for Medicare and Medicaid Services recommendations for lung cancer screening, low-dose chest computed tomography screening has moved from the research arena to clinical practice. Lung cancer screening programs must reach beyond image acquisition and interpretation and engage in a multidisciplinary effort of clinical shared decision-making, standardization of imaging and nodule management, smoking cessation, and patient follow-up. Standardization of radiologic reports and nodule management will systematize patient care, provide quality assurance, further reduce harm, and contain health care costs. Although the National Lung Screening Trial results and eligibility criteria of a heavy smoking history are the foundation for the standard guidelines for low-dose chest computed tomography screening in the United States, currently only 27% of patients diagnosed with lung cancer would meet US lung cancer screening recommendations. Current and future efforts must be directed to better delineate those patients who would most benefit from screening and to ensure that the benefits of screening reach all socioeconomic strata and racial and ethnic minorities. Further optimization of lung cancer screening program design and patient eligibility will assure that lung cancer screening benefits will outweigh the potential risks to our patients. PMID:27306387

  11. Cervical cancer screening.

    PubMed Central

    Katz, A.

    1998-01-01

    OBJECTIVE: To review the role of family physicians in screening for cancer of the cervix, to review the evidence for screening, in particular, frequency and technique for screening, and to review the reasons cervical cancer has not been prevented and the role of family physicians in addressing these failures. QUALITY OF EVIDENCE: The value of screening has been established with level II evidence. Many of the unresolved issues are not supported either way by good evidence; level II and III evidence predominates. MAIN FINDINGS: In Canada, 1350 women were predicted to be diagnosed with cancer of the cervix in 1996. Most of these women had not been screened. Minority, rural, low-income, and older women face important barriers to screening. Family physicians have a role in reaching out to these women to provide effective health care, including cancer screening. When cancer screening is performed, it should conform to recommended techniques with appropriate follow up of abnormal test results. CONCLUSIONS: Family physicians have an important role in preventing cancer of the cervix. Efforts should be concentrated on encouraging a greater proportion of eligible women to be screened. Criteria are suggested for effective screening. PMID:9721422

  12. Automated Groundwater Screening

    SciTech Connect

    Taylor, Glenn A.; Collard, Leonard, B.

    2005-10-31

    The Automated Intruder Analysis has been extended to include an Automated Ground Water Screening option. This option screens 825 radionuclides while rigorously applying the National Council on Radiation Protection (NCRP) methodology. An extension to that methodology is presented to give a more realistic screening factor for those radionuclides which have significant daughters. The extension has the promise of reducing the number of radionuclides which must be tracked by the customer. By combining the Automated Intruder Analysis with the Automated Groundwater Screening a consistent set of assumptions and databases is used. A method is proposed to eliminate trigger values by performing rigorous calculation of the screening factor thereby reducing the number of radionuclides sent to further analysis. Using the same problem definitions as in previous groundwater screenings, the automated groundwater screening found one additional nuclide, Ge-68, which failed the screening. It also found that 18 of the 57 radionuclides contained in NCRP Table 3.1 failed the screening. This report describes the automated groundwater screening computer application.

  13. Screening in liver disease.

    PubMed

    Del Poggio, Paolo; Mazzoleni, Marzio

    2006-09-01

    A disease is suitable for screening if it is common, if the target population can be identified and reached and if both a good screening test and an effective therapy are available. Of the most common liver diseases only viral hepatitis and genetic hemochromatosis partially satisfy these conditions. Hepatitis C is common, the screening test is good and the therapy eliminates the virus in half of the cases, but problems arise in the definition of the target population. In fact generalized population screening is not endorsed by international guidelines, although some recommend screening immigrants from high prevalence countries. Opportunistic screening (case finding) of individuals with classic risk factors, such as transfusion before 1992 and drug addiction, is the most frequently used strategy, but there is disagreement whether prison inmates, individuals with a history of promiscuous or traumatic sex and health care workers should be screened. In a real practice setting the performance of opportunistic screening by general practitioners is low but can be ameliorated by training programs. Screening targeted to segments of the population or mass campaigns are expensive and therefore interventions should be aimed to improve opportunistic screening and the detection skills of general practitioners. Regarding genetic hemochromatosis there is insufficient evidence for population screening, but individual physicians can decide to screen racial groups with a high prevalence of the disease, such as people in early middle age and of northern European origin. In the other cases opportunistic screening of high risk individuals should be performed, with a high level of suspicion in case of unexplained liver disease, diabetes, juvenile artropathy, sexual dysfunction and skin pigmentation. PMID:16981254

  14. System safety education focused on flight safety

    NASA Technical Reports Server (NTRS)

    Holt, E.

    1971-01-01

    The measures necessary for achieving higher levels of system safety are analyzed with an eye toward maintaining the combat capability of the Air Force. Several education courses were provided for personnel involved in safety management. Data include: (1) Flight Safety Officer Course, (2) Advanced Safety Program Management, (3) Fundamentals of System Safety, and (4) Quantitative Methods of Safety Analysis.

  15. Turbulent flow through screens

    NASA Technical Reports Server (NTRS)

    Mehta, R. D.

    1984-01-01

    A detailed experimental investigation has been carried out on the effects of different types of screens on turbulent flow, in particular turbulent boundary layers. The effect of a screen on a turbulent boundary layer is to give it a 'new lease of life'. The boundary layer turbulence is reorganized and the thickness reduced, thus making it less susceptible to separation. The aerodynamic properties of plastic screens are found to differ significantly from those of the conventional metal screens, evidently because of differences in the weaving properties. The 'overshoot' in mean velocity profile near the boudnary layer edge is shown to be a result of the effect of screen inclination on pressure drop coefficient. A more accurate formulation for the deflection coefficient of a screen is also proposed.

  16. Screening for Endometrial Cancer

    PubMed Central

    Nisker, Jeffrey A.

    1983-01-01

    Although population screening for cervical neoplasia is widely practiced, screening for endometrial neoplasia has only recently been considered. Before development of endometrial carcinoma, the endometrium undergoes progressive neoplastic alterations in a parallel fashion to the premalignant precursors of cervical carcinoma. Screening for endometrial carcinoma may be particularly appropriate because of the existence of a well defined, easily identifiable high risk group and tissue sampling techniques that are accurate, easy to perform, inexpensive, and well tolerated. Women at increased risk of endometrial carcinoma include: obese postmenopausal women, women on postmenopausal estrogen replacement therapy, premenopausal women with a history of anovulatory cycles (including women with polycystic ovarian disease) and women with hepatic cirrhosis. Using endometrial aspiration devices, screening for endometrial hyperplasia and carcinoma may be performed by any physician familiar with intrauterine contraceptive device insertion in the office. The impact of such routine screening of high risk women will be determined only after large screening studies have been accomplished. PMID:21283374

  17. Composite scintillator screen

    DOEpatents

    Zeman, Herbert D.

    1994-01-01

    A scintillator screen for an X-ray system includes a substrate of low-Z material and bodies of a high-Z material embedded within the substrate. By preselecting the size of the bodies embedded within the substrate, the spacial separation of the bodies and the thickness of the screen, the sensitivity of the screen to X-rays within a predetermined energy range can be predicted.

  18. Economics of blood screening: in search of an optimal blood screening strategy.

    PubMed

    Chinkhumba, Jobiba

    2006-01-01

    The objectives of this retrospective study were to assess the economic impact that the practice of 'family replacement donor system' has on the operational costs of a rural blood bank and to rationalize efficient blood screening protocols with a view to minimizing blood screening costs without compromising blood safety. Prevalence of transfusion-transmissible infections such as HIV, hepatitis B and syphilis were ascertained from records of 870 potential donors screened over a period of 6 months. Costs of screening tests were approximated by summing up costs of materials used per test. Overhead and labour costs were not factored in. Average and marginal costs of a fully-screened blood unit were calculated using different blood screening protocols. The average and marginal costs of a fully-screened blood unit vary greatly depending on the order in which screening tests are conducted. Although the variation in average costs per blood unit among different protocols is narrow, US 29.44 dollars to US 33 dollars, the variation in marginal costs is significantly wider ranging from US 22.79 dollars to US 51.85 dollars. Overall, 78 (9%) of the potential donors had HIV infection while 25 (3.2%) had hepatitis B infections and nine (1.2%) donors had syphilis. Co-infection rate was very low at 1.4%. The study shows that it is possible to prioritize blood screening tests for the selection of safe blood donors simply and cost-effectively in a developing country hospital. In the face of rapid rises in health-care spending, it is very important that essential health services such as blood screening are safely delivered with as little expenditure of financial resources as possible. To make sound economic decisions, average cost is not what matters but marginal cost, the cost of one more test. PMID:16483429

  19. Breast Cancer Screening.

    PubMed

    Euhus, David; Di Carlo, Philip A; Khouri, Nagi F

    2015-10-01

    Breast cancer screening has become a controversial topic. Understanding the points of contention requires an appreciation of the conceptual framework underpinning cancer screening in general, knowledge of the strengths and limitations of available screening modalities, and familiarity with published clinical trial data. This review is data intense with the intention of presenting enough information to permit the reader to enter into the discussion with an ample knowledge base. The focus throughout is striking a balance between the benefits and harms of breast cancer screening. PMID:26315519

  20. First Aid and Safety

    MedlinePlus

    ... First-Aid Kit Food Safety for Your Family Gun Safety Halloween Candy Hints Household Safety Checklists Household ... Climbing, and Grabbing Household Safety: Preventing Injuries From Firearms Household Safety: Preventing Injuries in the Crib Household ...

  1. Newborn screening in Indonesia.

    PubMed

    Rustama, Diet S; Fadil, M Ryadi; Harahap, Elly R; Primadi, Aris

    2003-01-01

    In Indonesia, newborn screening is not yet a policy, and the incidence of preventable causes of mental retardation detected by newborn screening is not known. Congenital hypothyroidism (CH) is not infrequent. Without a screening program, unrecognized CH patients were neglected for years. Since May 1999, the International Atomic Energy Agency (IAEA) has assisted in starting a CH Newborn Screening Project to estimate the local incidence of CH and to evaluate the problems associated with the screening. In June 2000, a pilot study was conducted using primary TSH measurement, supplemented by T4 in infants with elevated TSH. The target was to screen 12,000 newborn infants, using cord blood serum taken at birth, or a heel prick between 2 to 6 days of age. Between June 2000 and February 2001, 3,534 neonates born in 4 hospitals were screened using cord blood serum taken at birth (recall rate 3.3%). From March 2001 onwards, the heel prick method was used and participating hospitals increased from 4 to 7. Using this approach, until August 2001, 3,309 samples were analysed and the recall rate was much lower (0.64%). The number of unsatisfactory samples was relatively high due to an unstable process of blood collection. Parental refusal and low acceptance of screening among policy makers resulted from lack of awareness of the dangers of CH, and the screening program was not considered a health priority. Recall of patients after screening was a major barrier, with problems in tracking patients arising from urbanization and a high rate of relocation. To advance the CH screening program nationwide, infrastructure must be improved along with the recall system, and education as well as information campaigns for parents and medical professionals must be intensified. The Department of Health must be persuaded to give a national mandate. PMID:15906701

  2. Playground Safety.

    ERIC Educational Resources Information Center

    Sipes, James L.

    2000-01-01

    Discusses the issues of risk, liability, and fun when landscaping playgrounds with safety in mind. The importance of playground surfaces and several preventive measures landscapers can use to reduce the risk of injury are discussed. Concluding comments address playground design features and liability. (GR)

  3. School Safety.

    ERIC Educational Resources Information Center

    The Newsletter of the Comprehensive Center-Region VI, 1999

    1999-01-01

    The articles in this issue dealing with school safety discusses what rural and small urban settings are doing to prevent violence and to educate young people about prosocial alternatives to violence. The research is quite clear that female, minority, and gay students are the targets of a disproportionate amount of harassment and violence, both in…

  4. Safety First!

    ERIC Educational Resources Information Center

    Longfield, Judith

    2006-01-01

    In this article, the author relates how a hands-on chemistry investigation provided her the inspiration to develop an effective safety lesson for her third grade chemistry class. She began the lesson by demonstrating the use of pH indicator paper to show that ordinary household (white) vinegar was an acid. With the students, she wondered aloud…

  5. Art Safety.

    ERIC Educational Resources Information Center

    BCATA Journal for Art Teachers, 1991

    1991-01-01

    Advocating that Canadian art programs should use and model environmentally safe practices, the articles in this journal focus on issues of safe practices in art education. Articles are: (1) "What is WHMIS?"; (2) "Safety Precautions for Specific Art Processes"; (3) "Toxic Substances"; (4) "Using Clay, Glazes, and Kilns Safely in the Classroom"…

  6. Smart Screening System (S3) In Taconite Processing

    SciTech Connect

    Daryoush Allaei; Angus Morison; David Tarnowski; Asim Syed Mohammed

    2005-09-01

    The conventional screening machines used in processing plants have had undesirable high noise and vibration levels. They also have had unsatisfactorily low screening efficiency, high energy consumption, high maintenance cost, low productivity, and poor worker safety. These conventional vibrating machines have been used in almost every processing plant. Most of the current material separation technology uses heavy and inefficient electric motors with an unbalanced rotating mass to generate the shaking. In addition to being excessively noisy, inefficient, and high-maintenance, these vibrating machines are often the bottleneck in the entire process. Furthermore, these motors, along with the vibrating machines and supporting structure, shake other machines and structures in the vicinity. The latter increases maintenance costs while reducing worker health and safety. The conventional vibrating fine screens at taconite processing plants have had the same problems as those listed above. This has resulted in lower screening efficiency, higher energy and maintenance cost, and lower productivity and workers safety concerns. The focus of this work is on the design of a high performance screening machine suitable for taconite processing plants. SmartScreens{trademark} technology uses miniaturized motors, based on smart materials, to generate the shaking. The underlying technologies are Energy Flow Control{trademark} and Vibration Control by Confinement{trademark}. These concepts are used to direct energy flow and confine energy efficiently and effectively to the screen function. The SmartScreens{trademark} technology addresses problems related to noise and vibration, screening efficiency, productivity, and maintenance cost and worker safety. Successful development of SmartScreens{trademark} technology will bring drastic changes to the screening and physical separation industry. The final designs for key components of the SmartScreens{trademark} have been developed. The key

  7. Smart Screening System (S3) In Taconite Processing

    SciTech Connect

    Daryoush Allaei; Ryan Wartman; David Tarnowski; Asim Syed Mohammed

    2006-03-01

    The conventional screening machines used in processing plants have had undesirable high noise and vibration levels. They also have had unsatisfactorily low screening efficiency, high energy consumption, high maintenance cost, low productivity, and poor worker safety. These conventional vibrating machines have been used in almost every processing plant. Most of the current material separation technology uses heavy and inefficient electric motors with an unbalanced rotating mass to generate the shaking. In addition to being excessively noisy, inefficient, and high-maintenance, these vibrating machines are often the bottleneck in the entire process. Furthermore, these motors, along with the vibrating machines and supporting structure, shake other machines and structures in the vicinity. The latter increases maintenance costs while reducing worker health and safety. The conventional vibrating fine screens at taconite processing plants have had the same problems as those listed above. This has resulted in lower screening efficiency, higher energy and maintenance cost, and lower productivity and workers safety concerns. The focus of this work is on the design of a high performance screening machine suitable for taconite processing plants. SmartScreens{trademark} technology uses miniaturized motors, based on smart materials, to generate the shaking. The underlying technologies are Energy Flow Control{trademark} and Vibration Control by Confinement{trademark}. These concepts are used to direct energy flow and confine energy efficiently and effectively to the screen function. The SmartScreens{trademark} technology addresses problems related to noise and vibration, screening efficiency, productivity, and maintenance cost and worker safety. Successful development of SmartScreens{trademark} technology will bring drastic changes to the screening and physical separation industry. The final designs for key components of the SmartScreens{trademark} have been developed. The key

  8. Aneuploidy Screening in Pregnancy.

    PubMed

    Dashe, Jodi S

    2016-07-01

    Prenatal aneuploidy screening has changed dramatically in recent years with increases in the types of chromosomal abnormalities reliably identified and in the proportion of aneuploid fetuses detected. Initially, screening was available only for trisomies 21 and 18 and was offered only to low-risk pregnancies. Improved detection with the quadruple- and first-trimester multiple marker screens led to the option of aneuploidy screening for women 35 years of age and older. Cell-free DNA tests now screen for common autosomal trisomies and sex chromosome aneuploidies. Cell-free DNA screening is particularly effective in older women because of higher positive predictive values and lower false-positive rates. Integrated first- and second-trimester multiple marker tests provide specific risks for trisomies 21, 18, and possibly 13, and may detect an even wider range of aneuploidies. Given current precision in risk assessment, based on maternal age and preferences for screening or diagnostic tests, counseling has become more complex. This review addresses the benefits and limitations of available aneuploidy screening methods along with counseling considerations when offering them. PMID:27275786

  9. Preconception Carrier Screening

    MedlinePlus

    ... What can the results of a carrier screening test tell me? A genetic counselor or your health care provider will use the results to calculate the ... the publisher. Related FAQs Genetic Disorders (FAQ094) Screening Tests for Birth Defects ... Education & Events Annual Meeting CME Overview CREOG ...

  10. Screen time and children

    MedlinePlus

    ... screen, such as watching TV, working on a computer, or playing video games. Screen time is sedentary activity, meaning you are ... child eat while watching TV or using the computer. DO NOT leave the ... as family board games, puzzles, or going for a walk. Keep a ...

  11. Adolescent Communication Screen. Revised.

    ERIC Educational Resources Information Center

    Tisthammer, Patricia; And Others

    The Adolescent Communication Screen--a criterion-based instrument designed to provide speech-language clinicians a measure for screening the communication skills of students in grades 5 through 12--is described in this document. Included in the description are the instrument's subtests: vocabulary, temporal concepts, language comprehension,…

  12. Radiographic intensifying screen

    SciTech Connect

    Ochiai, T.

    1985-02-26

    A radiographic intensifying screen comprising a substrate and a fluorescent layer provided thereon and consisting essentially of a binder and a radioluminescent phosphor dispersed therein. The binder comprises linear polyester resin or linear polyester resin crosslinked with a crosslinking agent. The screen exhibits improved physical properties.

  13. Scoliosis Screening in Schools.

    ERIC Educational Resources Information Center

    New York State Education Dept., Albany. Div. of Pupil Personnel Services.

    The booklet outlines New York state school policy and procedures for screening students for scoliosis, lateral curvature of the spine. It is explained that screening is designed to discover spinal deformities early enough to prevent surgery. Planning aspects, including organizing a planning team for the school district, are discussed. Among…

  14. Screening for adverse events.

    PubMed

    Karson, A S; Bates, D W

    1999-02-01

    Adverse events (AEs) in medical patients are common, costly, and often preventable. Development of quality improvement programs to decrease the number and impact of AEs demands effective methods for screening for AEs on a routine basis. Here we describe the impact, types, and potential causes of AEs and review various techniques for identifying AEs. We evaluate the use of generic screening criteria in detail and describe a recent study of the sensitivity and specificity of individual generic screening criteria and combinations of these criteria. In general, the most sensitive screens were the least specific and no small sub-set of screens identified a large percentage of adverse events. Combinations of screens that were limited to administrative data were the least expensive, but none were particularly sensitive, although in practice they might be effective since routine screening is currently rarely done. As computer systems increase in sophistication sensitivity will improve. We also discuss recent studies that suggest that programs that screen for and identify AEs can be useful in reducing AE rates. While tools for identifying AEs have strengths and weaknesses, they can play an important role in organizations' quality improvement portfolios. PMID:10468381

  15. Ocular Screening System

    NASA Technical Reports Server (NTRS)

    1985-01-01

    An ocular screening system designed for safe, convenient screening of large groups was developed at Marshall Space Flight Center, leading to the formation of Medical Sciences Corporation. The system identifies visual defects accurately and inexpensively, and includes a photorefractor telephoto lens and an electronic flash. Medical Sciences Corporation is using the device to test at schools, industrial plants, etc.

  16. Cellular imaging: a key phenotypic screening strategy for predictive toxicology

    PubMed Central

    Xu, Jinghai J.

    2015-01-01

    Incorporating phenotypic screening as a key strategy enhances predictivity and translatability of drug discovery efforts. Cellular imaging serves as a “phenotypic anchor” to identify important toxicologic pathology that encompasses an array of underlying mechanisms, thus provides an effective means to reduce drug development failures due to insufficient safety. This mini-review highlights the latest advances in hepatotoxicity, cardiotoxicity, and genetic toxicity tests that utilized cellular imaging as a screening strategy, and recommends path forward for further improvement. PMID:26441648

  17. Psychological screening program overview.

    PubMed

    Wright, Kathleen M; Huffman, Ann H; Adler, Amy B; Castro, Carl A

    2002-10-01

    This article reviews the literature on health surveillance conducted during military deployments, focusing on models for assessing the impact of operational deployments on peacekeepers. A discussion of the stressors and potential mental health consequences of peacekeeping operations follows with relevant examples of findings from U.S. and international military forces. Psychological screening in different peacekeeping operations conducted in U.S. Army-Europe is reviewed. The review begins with the redeployment screening of military personnel deployed to Bosnia mandated under the Joint Medical Surveillance Program, and continues through the present screening of units deployed to Kosovo. The detailed description of the screening program includes a discussion of procedures and measures and demonstrates the evolution of the program. A summary of key findings from the screening program and a discussion of future research directions are provided. PMID:12392255

  18. Screening for Barrett's Esophagus.

    PubMed

    di Pietro, Massimiliano; Chan, Daniel; Fitzgerald, Rebecca C; Wang, Kenneth K

    2015-05-01

    The large increase in the incidence of esophageal adenocarcinoma in the West during the past 30 years has stimulated interest in screening for Barrett's esophagus (BE), a precursor to esophageal cancer. Effective endoscopic treatments for dysplasia and intramucosal cancer, coupled with screening programs to detect BE, could help reverse the increase in the incidence of esophageal cancer. However, there are no accurate, cost-effective, minimally invasive techniques available to screen for BE, reducing the enthusiasm of gastroenterologists. Over the past 5 years, there has been significant progress in the development of screening technologies. We review existing and developing technologies, new minimally invasive imaging techniques, nonendoscopic devices for cell collection, and biomarkers that can be measured in blood or stool samples. We discuss the status of these approaches, data from clinical studies of their effects, and their anticipated strengths and weaknesses in screening. The area is rapidly evolving, and new tools will soon be ready for prime time. PMID:25701083

  19. Safety harness

    DOEpatents

    Gunter, Larry W.

    1993-01-01

    A safety harness to be worn by a worker, especially a worker wearing a plastic suit thereunder for protection in a radioactive or chemically hostile environment, which safety harness comprises a torso surrounding portion with at least one horizontal strap for adjustably securing the harness about the torso, two vertical shoulder straps with rings just forward of the of the peak of the shoulders for attaching a life-line and a pair of adjustable leg supporting straps releasibly attachable to the torso surrounding portion. In the event of a fall, the weight of the worker, when his fall is broken and he is suspended from the rings with his body angled slightly back and chest up, will be borne by the portion of the leg straps behind his buttocks rather than between his legs. Furthermore, the supporting straps do not restrict the air supplied through hoses into his suit when so suspended.

  20. Safety valve

    DOEpatents

    Bergman, Ulf C.

    1984-01-01

    The safety valve contains a resilient gland to be held between a valve seat and a valve member and is secured to the valve member by a sleeve surrounding the end of the valve member adjacent to the valve seat. The sleeve is movable relative to the valve member through a limited axial distance and a gap exists between said valve member and said sleeve.

  1. Farm Safety

    PubMed Central

    Wilson, G. S.

    1966-01-01

    Accident and safety are related terms; the higher the accident rate in any industry, the greater is the need for safety measures designed to prevent accidents. This article discusses the accident and safety problems in agriculture, which includes horticulture and forestry. There is still a tendency among townspeople to think of the countryside as peaceful and tranquil, a place where nothing happens very quickly and far removed from violent death or crippling injury. This pleasant rustic picture has undergone a striking change in the last 30 years owing to considerable agricultural mechanization and the development of chemical pesticides, which have brought new dangers to those who live and work on the land. Although men have readily adapted themselves to new machines and methods, they have not proved as able to recognize new dangers and learn how to guard against them. In consequence, accidents have increased to such an extent that the whole industry has realized the need for positive preventive measures. In this country, it is generally accepted that an employer of labour has a responsibility to provide safe working conditions for those he employs. Farm safety legislation goes a little further and usually requires an employer to provide necessary safeguards, with the added requirement on a worker to make use of them. It is a feature of accident prevention work that it never reaches a stage when it can be regarded as complete. Even when a reduction in accidents has been achieved, the effort must be sustained or the trend will be quickly reversed. Images PMID:5904095

  2. Lung Cancer Screening.

    PubMed

    Wu, Geena X; Raz, Dan J

    2016-01-01

    Lung cancer is the leading cause of cancer mortality in the United States and worldwide. Since lung cancer outcomes are dependent on stage at diagnosis with early disease resulting in longer survival, the goal of screening is to capture lung cancer in its early stages when it can be treated and cured. Multiple studies have evaluated the use of chest X-ray (CXR) with or without sputum cytologic examination for lung cancer screening, but none has demonstrated a mortality benefit. In contrast, the multicenter National Lung Screening Trial (NLST) from the United States found a 20 % reduction in lung cancer mortality following three consecutive screenings with low-dose computed tomography (LDCT) in high-risk current and former smokers. Data from European trials are not yet available. In addition to a mortality benefit, lung cancer screening with LDCT also offers a unique opportunity to promote smoking cessation and abstinence and may lead to the diagnoses of treatable chronic diseases, thus decreasing the overall disease burden. The risks of lung cancer screening include overdiagnosis, radiation exposure, and false-positive results leading to unnecessary testing and possible patient anxiety and distress. However, the reduction in lung cancer mortality is a benefit that outweighs the risks and major health organizations currently recommend lung cancer screening using age, smoking history, and quit time criteria derived from the NLST. Although more research is needed to clearly define and understand the application and utility of lung cancer screening in the general population, current data support that lung cancer screening is effective and should be offered to eligible beneficiaries. PMID:27535387

  3. Medicare Preventive and Screening Services

    MedlinePlus

    ... covered? Search Medicare.gov for covered items Preventive & screening services How often is it covered? Medicare Part B (Medical Insurance) covers: Abdominal aortic aneurysm screening Alcohol misuse screenings & counseling Bone mass measurements (bone ...

  4. Screening and diagnosis for HIV

    MedlinePlus

    HIV testing; HIV screening; HIV screening test; HIV confirmatory test ... A positive result on a screening test does not confirm that the person has HIV infection. More tests are needed to confirm HIV infection. A negative test ...

  5. Cervical cancer - screening and prevention

    MedlinePlus

    Cancer cervix - screening; HPV - cervical cancer screening; Dysplasia - cervical cancer screening ... Almost all cervical cancers are caused by HPV (human papilloma virus). HPV is a common virus that spreads through sexual contact. Certain types ...

  6. Controversies in Screening Mammography.

    PubMed

    Swain, Monique; Jeudy, Myrlene; Pearlman, Mark D

    2016-06-01

    The utility and effectiveness of screening mammography in diagnosing breast cancer at earlier stages and reducing disease-specific mortality remain controversial especially as to when to start and stop routine mammographic screening, and whether mammograms should be performed annually or biennially in average-risk women. This manuscript will analyze the available moderate and high-quality data to analyze both the benefits (lives saved and life-years saved) and inconveniences/harms (additional views, extra biopsies/overdiagnosis, and overtreatment of ductal carcinoma in situ) of different mammography screening guidelines to assist the practitioner in counseling their patients in clinical practice. PMID:27101240

  7. Screening for Developmental Disabilities

    PubMed Central

    Foster, Carol; Duran-Flores, Deborah; Dumars, Kenneth W.; Stills, Stanley

    1985-01-01

    Developmental disabilities are responsible for a combination of severe physical, mental, psychological and social deficits. They develop before age 22 years and involve a little more than 1% of the population. Screening for developmental disabilities is the first step in their prevention. Various screening instruments are available for use throughout the developmental years that are designed to detect the wide variety of developmental problems that interfere with a developing person's optimal adaptation to his or her environment. The screening instruments must be inexpensive, reproducible, widely available and cost effective to the child, family and society. PMID:2413633

  8. Screening for Lung Cancer.

    PubMed

    Stiles, Brendon M; Pua, Bradley; Altorki, Nasser K

    2016-07-01

    Lung cancer is a global health burden and is among the most common and deadliest of all malignancies worldwide. The goal of screening programs is to detect tumors in earlier, curable stages, consequently reducing disease-specific mortality. The issue of screening has great relevance to thoracic surgeons, who should play a leading role in the debate over screening and its consequences. The burden is on thoracic surgeons to work in a multidisciplinary setting to guide and treat these patients safely and responsibly, ensuring low morbidity and mortality of potential diagnostic or therapeutic interventions. PMID:27261909

  9. International standards for pandemic screening using infrared thermography

    NASA Astrophysics Data System (ADS)

    Pascoe, D. D.; Ring, E. F.; Mercer, J. B.; Snell, J.; Osborn, D.; Hedley-Whyte, J.

    2010-03-01

    The threat of a virulent strain of influenza, severe acute respiratory syndrome (SARS), tuberculosis, H1N1/A virus (swine flu) and possible mutations are a constant threat to global health. Implementation of pandemic infrared thermographic screening is based on the detection of febrile temperatures (inner canthus of the eyes) that are correlated with an infectious disease. Previous attempts at pandemic thermal screening have experienced problems (e.g. SARS outbreak, Singapore 2003) associated with the deployment plan, implementation and operation of the screening thermograph. Since this outbreak, the International Electrotechnical Commission has developed international standards that set minimum requirements for thermographic system fever screening and procedures that insure reliable and reproducible measurements. These requirements are published in IEC 80601-2-59:2008, Medical electrical equipment - Part 2-59: Particular requirements for the basic safety and essential performance of screening thermographs for human febrile temperature screening. The International Organization for Standardization has developed ISO/TR 13154:2009, Medical Electrical Equipment - which provides deployment, implementation and operational guidelines for identifying febrile humans using a screening thermograph. These new standards includes recommendations for camera calibrations, use of black body radiators, view field, focus, pixels within measurement site, image positioning, and deployment locations. Many current uses of thermographic screening at airports do not take into account critical issues addressed in the new standard, and are operating below the necessary effectiveness and efficiency. These documents, related thermal research, implications for epidemiology screening, and the future impact on medical thermography are discussed.

  10. Urine drug screen

    MedlinePlus

    Drug screen -- urine ... detect the presence of illegal and some prescription drugs in your urine. Their presence indicates that you recently used these drugs. Some drugs may remain in your system for ...

  11. Screening for Cervical Cancer

    MedlinePlus

    ... of these tests as well as the possible harms, both of which are explained below. This fact ... after receiving abnormal test results. Benefits and Possible Harms The main benefit of screening is that it ...

  12. Screening for Glaucoma

    MedlinePlus

    ... enough evidence to determine the potential benefits and harms of glaucoma screening for adults who do not ... Glaucoma is a group of diseases that can harm the eye’s optic nerve. The optic nerve carries ...

  13. Environmental Stress Screening 2000

    NASA Technical Reports Server (NTRS)

    Gibbel, Mark

    1997-01-01

    The following identifies the authors of this report and the organizations that sponsored the effort conducted under the National Center for Manufacturing Sciences (NCMS) Environmental Stress Screening (ESS) 2000 Project.

  14. Early School Screening Practices

    ERIC Educational Resources Information Center

    Maitland, Suzanne; And Others

    1974-01-01

    To ascertain the prevalence of early school screening practices, the specific tests employed, and the use made of the test results, a survey was conducted of a representative sample of 980 school districts in the United States. (Author)

  15. Screening Tests for Women

    MedlinePlus

    ... or colonoscopy) Diabetes screening Gonorrhea test HIV test Syphilis test Get tested for chlamydia yearly through age ... to be tested for HIV. Get tested for syphilis if you are at increased risk or pregnant. ...

  16. Screening for Prostate Cancer

    MedlinePlus

    ... difficult to assess the effect of lead-time bias on the reported rates. Men with screen-detected ... and Treatment Two poor-quality (high risk of bias) randomized, con- trolled trials initiated in the 1980s ...

  17. The 'GALS' locomotor screen.

    PubMed Central

    Doherty, M; Dacre, J; Dieppe, P; Snaith, M

    1992-01-01

    The locomotor system is complex and difficult to examine. A selective clinical process to detect important locomotor abnormalities and functional disability could prove valuable. A screen based on a tested 'minimal' history and examination system is described, together with a simple method of recording. The screen is fast and easy to perform. As well as providing a useful introduction to examination of the locomotor system, the screen includes objective observation of functional movements relevant to activities of daily living. Its inclusion in the undergraduate clerking repertoire could improve junior doctors' awareness and recognition of rheumatic disease and general disability. It could also provide a valuable screening test for use in general practice. Images PMID:1444632

  18. Newborn screening tests

    MedlinePlus

    ... at least 26 disorders on an expanded and standardized uniform panel. The most thorough screening panel checks ... diagnose illnesses. They show which babies need more testing to confirm or rule out illnesses. If follow- ...

  19. Prostate Cancer Screening

    MedlinePlus

    ... treat. There is no standard screening test for prostate cancer. Researchers are studying different tests to find those ... PSA level may be high if you have prostate cancer. It can also be high if you have ...

  20. Screening for Depression

    MedlinePlus

    ... events Visit the podcast archive Mood Disorders Depression Bipolar Disorder Anxiety Screening Center Co-occurring Illnesses/Disorders Related ... for Your Patients Information about Depression Information about Bipolar Disorder Wellness Tools DBSA Support Groups Active Research Studies ...

  1. Colorectal Cancer Screening

    MedlinePlus

    ... screening tests are being studied in clinical trials. Virtual colonoscopy Virtual colonoscopy is a procedure that uses ... complications may occur more often in older patients. Virtual colonoscopy Virtual colonoscopy often finds problems with organs ...

  2. Pap Smear Screening Rates

    PubMed Central

    Calam, Betty; Bass, Martin; Deagle, George

    1992-01-01

    A cross-sectional study of 196 women on the Queen Charlotte Islands showed that significantly fewer Haida women than non-Native women had adequate cervical screening. Differences were most marked in the 60 and older age group. Qualitative research to elucidate cultural factors could aid in planning screening programs that would be accepted by all women at risk in the community. PMID:21221327

  3. Screening for colorectal cancer.

    PubMed Central

    Campbell, W. J.; Moorehead, R. J.

    1997-01-01

    Colorectal carcinoma represents a major cause of cancer deaths in the United Kingdom. Tumours detected at an early or even premalignant stage have a better prognosis. In this review we consider the argument for screening for colorectal carcinomas and discuss the means available and the implications of implementing screening programmes using some of these methods. A suggestion is made for the more rational use of limited resources to target those at greatest risk. PMID:9185482

  4. Safety and Liability.

    ERIC Educational Resources Information Center

    Berthelot, Ronald J.; And Others

    1982-01-01

    This series of five articles highlights Pensacola Junior College's occupational safety course, involving simulated emergencies, Florida's standards for teacher liability, electrical safety in the classroom and laboratory, color coding for machine safety, and Florida industrial arts safety instructional materials. (SK)

  5. Screening of solar cells

    NASA Technical Reports Server (NTRS)

    Appelbaum, J.; Chait, A.; Thompson, D. A.

    1993-01-01

    Because solar cells in a production batch are not identical, screening is performed to obtain similar cells for aggregation into arrays. A common technique for screening is based on a single operating point of the I-V characteristic of the cell, usually the maximum power point. As a result, inferior cell matching may occur at the actual operating points. Screening solar cells based on the entire I-V characteristic will inherently result in more similar cells in the array. An array consisting of more similar cells is likely to have better overall characteristics and more predictable performance. Solar cell screening methods and cell ranking are discussed. The concept of a mean cell is defined as a cell 'best' representing all the cells in the production batch. The screening and ranking of all cells are performed with respect to the mean cell. The comparative results of different screening methods are illustrated on a batch of 50 silicon cells of the Space Station Freedom.

  6. Screening of solar cells

    SciTech Connect

    Appelbaum, J.; Chait, A.; Thompson, D.A.

    1993-07-01

    Because solar cells in a production batch are not identical, screening is performed to obtain similar cells for aggregation into arrays. A common technique for screening is based on a single operating point of the I-V characteristic of the cell, usually the maximum power point. As a result, inferior cell matching may occur at the actual operating points. Screening solar cells based on the entire I-V characteristic will inherently result in more similar cells in the array. An array consisting of more similar cells is likely to have better overall characteristics and more predictable performance. Solar cell screening methods and cell ranking are discussed. The concept of a mean cell is defined as a cell 'best' representing all the cells in the production batch. The screening and ranking of all cells are performed with respect to the mean cell. The comparative results of different screening methods are illustrated on a batch of 50 silicon cells of the Space Station Freedom.

  7. Safety Grooving

    NASA Technical Reports Server (NTRS)

    1985-01-01

    Safety grooving, the cutting of grooves in concrete to increase traction and prevent injury, was first developed to reduce aircraft accidents on wet runways. Represented by the International Grooving and Grinding Association (IG&GA), the industry expanded into highway and pedestrian applications. The technique originated at Langley, which assisted in testing the grooving at airports and on highways. Skidding was reduced, stopping distance decreased, and a vehicle's cornering ability on curves was increased. The process has been extended to animal holding pens, steps, parking lots and other potentially slippery surfaces.

  8. Delivering safety

    SciTech Connect

    Baldwin, N.D.; Spooner, K.G.; Walkden, P.

    2007-07-01

    In the United Kingdom there have been significant recent changes to the management of civil nuclear liabilities. With the formation in April 2005 of the Nuclear Decommissioning Authority (NDA), ownership of the civil nuclear licensed sites in the UK, including the Magnox Reactor Stations, passed to this new organisation. The NDAs mission is to seek acceleration of the nuclear clean up programme and deliver increased value for money and, consequently, are driving their contractors to seek more innovative ways of performing work. British Nuclear Group manages the UK Magnox stations under contract to the NDA. This paper summarises the approach being taken within its Reactor Sites business to work with suppliers to enhance working arrangements at sites, improve the delivery of decommissioning programmes and deliver improvements in safety and environmental performance. The UK Magnox stations are 1. generation gas-graphite reactors, constructed in the 1950's and 1960's. Two stations are currently still operating, three are shut-down undergoing defueling and the other five are being decommissioned. Despite the distractions of industry restructuring, an uncompromising policy of demanding improved performance in conjunction with improved safety and environmental standards has been adopted. Over the past 5 years, this policy has resulted in step-changes in performance at Reactor Sites, with increased electrical output and accelerated defueling and decommissioning. The improvements in performance have been mirrored by improvements in safety (DACR of 0 at 5 sites); environmental standards (reductions in energy and water consumption, increased waste recycling) and the overall health of the workforce (20% reduction in sickness absence). These achievements have, in turn, been recognised by external bodies, resulting in several awards, including: the world's first ISRS and IERS level 10 awards (Sizewell, 2006), the NUMEX plant maintenance award (Bradwell, 2006), numerous Ro

  9. 8. DETAIL OF COMPUTER SCREEN AND CONTROL BOARDS: LEFT SCREEN ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. DETAIL OF COMPUTER SCREEN AND CONTROL BOARDS: LEFT SCREEN TRACKS RESIDUAL CHLORINE; INDICATES AMOUNT OF SUNLIGHT WHICH ENABLES OPERATOR TO ESTIMATE NEEDED CHLORINE; CENTER SCREEN SHOWS TURNOUT STRUCTURES; RIGHT SCREEN SHOWS INDICATORS OF ALUMINUM SULFATE TANK FARM. - F. E. Weymouth Filtration Plant, 700 North Moreno Avenue, La Verne, Los Angeles County, CA

  10. SMART SCREENING SYSTEM (S3) IN TACONITE PROCESSING

    SciTech Connect

    Daryoush Allaei; Asim Syed Mohammed

    2004-04-01

    The conventional vibrating machines used in processing plants have had undesirable high noise and vibration levels. They also have had unsatisfactorily low screening efficiency, high energy consumption, high maintenance cost, low productivity, and poor worker safety. These conventional vibrating machines have been used in most every processing plant. Most of the current material separation technology uses heavy and inefficient electric motors with an unbalance rotating mass to generate the shaking. In addition to being excessively noisy, inefficient, high-maintenance, these vibrating machines are often the bottleneck in the entire process. Furthermore, these motors along with the vibrating machines and supporting structure shake other machines and structure in the vicinity. The latter increases maintenance costs while reducing worker health and safety. The conventional vibrating fine screens at taconite processing plants have had the same problems as those listed above. This has resulted in lower screening efficiency, higher energy and maintenance cost, and lower productivity and workers safety concerns. The focus of this work is on the design of a high performance screening machine suitable for taconite processing plants. SmartScreens{trademark} technology uses miniaturized motors, based on smart materials, to generate the shaking. The underlying technologies are Energy Flow Control{trademark} and Vibration Control by Confinement{trademark}. These concepts are used to direct energy flow and confine energy efficiently and effectively to the screen function. The SmartScreens{trademark} technology addresses problems related to noise and vibration, screening efficiency, productivity, and maintenance cost and worker safety. Successful development of SmartScreens{trademark} technology will bring drastic changes to the screening and physical separation industry. The conceptual designs for key components of the SmartScreens{trademark} have been developed. These key

  11. Smart Screening System (S3) In Taconite Processing

    SciTech Connect

    Daryoush Allaei; Asim Syed Mohammed; David Tarnowski

    2004-05-01

    The conventional vibrating machines used in processing plants have had undesirable high noise and vibration levels. They also have had unsatisfactorily low screening efficiency, high energy consumption, high maintenance cost, low productivity, and poor worker safety. These conventional vibrating machines have been used in most every processing plant. Most of the current material separation technology uses heavy and inefficient electric motors with an unbalance rotating mass to generate the shaking. In addition to being excessively noisy, inefficient, and high-maintenance, these vibrating machines are often the bottleneck in the entire process. Furthermore, these motors, along with the vibrating machines and supporting structure, shake other machines and structures in the vicinity. The latter increases maintenance costs while reducing worker health and safety. The conventional vibrating fine screens at taconite processing plants have had the same problems as those listed above. This has resulted in lower screening efficiency, higher energy and maintenance cost, and lower productivity and workers safety concerns. The focus of this work is on the design of a high performance screening machine suitable for taconite processing plants. SmartScreens{trademark} technology uses miniaturized motors, based on smart materials, to generate the shaking. The underlying technologies are Energy Flow Control{trademark} and Vibration Control by Confinement{trademark}. These concepts are used to direct energy flow and confine energy efficiently and effectively to the screen function. The SmartScreens{trademark} technology addresses problems related to noise and vibration, screening efficiency, productivity, and maintenance cost and worker safety. Successful development of SmartScreens{trademark} technology will bring drastic changes to the screening and physical separation industry. The final designs for key components of the SmartScreens{trademark} have been developed. The key

  12. Ethical issues evolving from patients’ perspectives on compulsory screening for syphilis and voluntary screening for cervical cancer in Kenya

    PubMed Central

    2014-01-01

    Background Public health aims to provide universal safety and progressive opportunities to populations to realise their highest level of health through prevention of disease, its progression or transmission. Screening asymptomatic individuals to detect early unapparent conditions is an important public health intervention strategy. It may be designed to be compulsory or voluntary depending on the epidemiological characteristics of the disease. Integrated screening, including for both syphilis and cancer of the cervix, is a core component of the national reproductive health program in Kenya. Screening for syphilis is compulsory while it is voluntary for cervical cancer. Participants’ perspectives of either form of screening approach provide the necessary contextual information that clarifies mundane community concerns. Methods Focus group discussions with female clients screened for syphilis and cancer of the cervix were conducted to elicit their perspectives of compulsory and voluntary screening. The discussions were audiotaped, transcribed and thematic content analysis performed manually to explore emerging ethics issues. Results The results indicate that real ethical challenges exist in either of the approaches. Also, participants were more concerned about the benefits of the procedure and whether their dignity is respected than the compulsoriness of screening per se. The implication is for the policy makers to clarify in the guidelines how to manage ethical challenges, while at the operational level, providers need to be judicious to minimize potential harms participants and families when screening for disease in women. Conclusions The context for mounting screening as a public health intervention and attendant ethical issues may be more complex than hitherto perceived. Interpreting emerging ethics issues in screening requires more nuanced considerations of individuals’ contextual experiences since these may be contradictory to the policy position. In

  13. Implementation of a comprehensive MR safety course for medical students.

    PubMed

    Sammet, Steffen; Sammet, Christina L

    2015-12-01

    This review article proposes the design of an educational magnetic resonance (MR) safety course for instructing medical students about basic MR and patient-related safety. The MR safety course material can be implemented as a traditional didactic or interactive lecture in combination with hands-on safety demonstrations. The goal of the course is to ensure that medical students receive a basic understanding of MR principles and safety considerations. This course will prepare medical students for patient screening and safety consultations when ordering MR studies. A multiple-choice exam can be used to document the proficiency in MR safety of the medical students. The course can be used by various medical school programs and may help to ensure consistent quality of teaching materials and MR safety standards. PMID:26172156

  14. Fragment screening: an introduction.

    PubMed

    Leach, Andrew R; Hann, Michael M; Burrows, Jeremy N; Griffen, Ed J

    2006-09-01

    There are clearly many different philosophies associated with adapting fragment screening into mainstream Drug Discovery Lead Generation strategies. Scientists at Astex, for instance, focus entirely on strategies involving use of X-ray crystallography and NMR. However, AstraZeneca uses a number of different fragment screening strategies. One approach is to screen a 2000 compound fragment set (with close to "lead-like" complexity) at 100 microM in parallel with every HTS such that the data are obtained on the entire screening collection at 10 microM plus the extra samples at 100 microM; this provides valuable compound potency data in a concentration range that is usually unexplored. The fragments are then screen-specific "privileged structures" that can be searched for in the rest of the HTS output and other databases as well as having synthesis follow-up. A typical workflow for a fragment screen within AstraZeneca is shown below (Figure 24) and highlights the desirability (particularly when screening >100 microM) for NMR and X-ray information to validate weak hits and give information on how to optimise them. In this chapter, we have provided an introduction to the theoretical and practical issues associated with the use of fragment methods and lead-likeness. Fragment-based approaches are still in an early stage of development and are just one of many interrelated techniques that are now used to identify novel lead compounds for drug development. Fragment based screening has some advantages, but like every other drug hunting strategy will not be universally applicable. There are in particular some practical challenges associated with fragment screening that relate to the generally lower level of potency that such compounds initially possess. Considerable synthetic effort has to be applied for post-fragment screening to build the sort of potency that would be expected to be found from a traditional HTS. However, if there are no low-hanging fruit in a screening

  15. Consensus statements for screening and assessment tools.

    PubMed

    Bédard, Michel; Dickerson, Anne E

    2014-04-01

    Occupational therapists, both generalists and specialists, have a critical role in providing services to senior drivers. These services include evaluating fitness-to-drive, developing interventions to support community mobility, and facilitating the transition from driving to non-driving when necessary for personal and community safety. The evaluation component and decision-making process about fitness-to-drive are highly dependent on the use of screening and assessment tools. The purpose of this paper is to briefly present the rationale and context for 12 consensus statements about the usefulness and appropriateness of screening and assessment tools to determine fitness-to-drive, within the occupational therapy clinical setting, and their implications on community mobility. PMID:24754760

  16. Statistical identification of effective input variables. [SCREEN

    SciTech Connect

    Vaurio, J.K.

    1982-09-01

    A statistical sensitivity analysis procedure has been developed for ranking the input data of large computer codes in the order of sensitivity-importance. The method is economical for large codes with many input variables, since it uses a relatively small number of computer runs. No prior judgemental elimination of input variables is needed. The sceening method is based on stagewise correlation and extensive regression analysis of output values calculated with selected input value combinations. The regression process deals with multivariate nonlinear functions, and statistical tests are also available for identifying input variables that contribute to threshold effects, i.e., discontinuities in the output variables. A computer code SCREEN has been developed for implementing the screening techniques. The efficiency has been demonstrated by several examples and applied to a fast reactor safety analysis code (Venus-II). However, the methods and the coding are general and not limited to such applications.

  17. Screening for lung cancer.

    PubMed

    Miettinen, O S

    2000-05-01

    Screening for lung cancer serves to prevent deaths from this disease insofar as earlier resections are associated with higher rates of cure. There is good reason to believe that this is the case: in stage I, the 5-year survival rate with resection is 70%, whereas without resection the corresponding rate is only 10%. Before this evidence emerged, various authoritative organizations and agencies in North America advised against screening for lung cancer on the grounds of the results of several RCTs. As for CXR, I argue that the study results are consistent with up to 40% reduction in the fatality rate. Moreover, modern helical CT screening provides for detecting much smaller tumors than were detected in those studies. It is time to revoke the conclusion that screening for lung cancer does not serve to prevent deaths from this disease, and to quantify the usefulness of CT screening in particular. As for the requisite research, the prevailing orthodoxy has it that RCTs are to be used, but I argue that more meaningful results are obtainable, more rapidly and much less expensively, by the use of noncomparative (and hence unrandomized) studies. PMID:10855255

  18. Report of a Health Screening Project in Pre-School Programs.

    ERIC Educational Resources Information Center

    Grever, Elizabeth

    This paper describes a preschool health screening service in which nurses, contracted through the Visiting Nurse Association, are assigned to day care centers receiving Title XX funds. The program focuses on health, safety and nutrition education. Screening includes history and physical assessment, developmental assessment, assessment or updating…

  19. Diagnostic Methods for Platelet Bacteria Screening: Current Status and Developments

    PubMed Central

    Störmer, Melanie; Vollmer, Tanja

    2014-01-01

    Summary Bacterial contamination of blood components and the prevention of transfusion-associated bacterial infection still remains a major challenge in transfusion medicine. Over the past few decades, a significant reduction in the transmission of viral infections has been achieved due to the introduction of mandatory virus screening. Platelet concentrates (PCs) represent one of the highest risks for bacterial infection. This is due to the required storage conditions for PCs in gas-permeable containers at room temperature with constant agitation, which support bacterial proliferation from low contamination levels to high titers. In contrast to virus screening, since 1997 in Germany bacterial testing of PCs is only performed as a routine quality control or, since 2008, to prolong the shelf life to 5 days. In general, bacterial screening of PCs by cultivation methods is implemented by the various blood services. Although these culturing systems will remain the gold standard, the significance of rapid methods for screening for bacterial contamination has increased over the last few years. These new methods provide powerful tools for increasing the bacterial safety of blood components. This article summarizes the course of policies and provisions introduced to increase bacterial safety of blood components in Germany. Furthermore, we give an overview of the different diagnostic methods for bacterial screening of PCs and their current applicability in routine screening processes. PMID:24659944

  20. Safety Is 99 Percent Attitude: Strategies to Contain Workers' Compensation Costs.

    ERIC Educational Resources Information Center

    Parnell, Janet

    1993-01-01

    The University of Denver (Colorado) reduced workers' compensation losses 97 percent in 1990-91 by developing a master safety plan, sponsoring safety training, managing medical costs, providing modified duty for injured employees, screening applicants, orienting new employees, investigating claims thoroughly, performing life-safety audits, and…

  1. [Colorectal cancer screening].

    PubMed

    Castells, Antoni

    2013-10-01

    Colorectal cancer is the paradigm of tumoral growth that is susceptible to preventive measures, especially screening. Various screening strategies with demonstrated efficacy and efficiency are currently available, notable examples being the fecal occult blood test and endoscopic tests. In addition, new modalities have appeared in the last few years that could become viable alternatives in the near future. The present article reviews the most important presentations on colorectal screening at the annual congress of the American Gastroenterological Association held in Orlando in May 2013, with special emphasis on the medium- and long-term results of strategies using the fecal occult blood test and flexible sigmoidoscopy, as well as initial experiences with the use of new biomarkers. PMID:24160954

  2. The PLCO Cancer Screening Trial: Background, Goals, Organization, Operations, Results.

    PubMed

    Gohagan, John K; Prorok, Philip C; Greenwald, Peter; Kramer, Barnett S

    2015-01-01

    The randomized PLCO trial was designed to answer four primary questions: does screening for these cancers using often promoted tests reduce cancer-specific mortality? Nearly 155,000 men and women were allocated to screening or usual care arms in a 1:1 ratio under a centralized, secure randomization algorithm at ten competitively selected screening centers nationwide. Screened men received PSA blood tests and digital rectal examinations. Screened women received CA125 blood tests and trans-vaginal ultrasound. Both men and women in the screened arm received anterolateral view chest x-ray and 60 cm flexible sigmoidoscopy. Blood specimens were collected at each screening visit and buccal cell DNA was collected once from the usual care participants. Histology slides were collected for cancer cases. Participants completed a baseline questionnaire covering health and risk factors and a dietary questionnaire. Data collected on standardized machine-readable forms were scanned remotely at screening and laboratory sites utilizing PLCO dedicated, NCI provided and configured computer systems for quality checks, archiving, and analysis. Comprehensive quality assurance was implemented over recruitment, consenting, randomization, screening, data management, records keeping, patient-specific screening results reporting, follow-up, and data analysis. Performance and data quality were monitored on-site and remotely by data edits, site visits, and random record audits. Specially trained and certified professionals performed screening procedures and medical record abstracting. An independent committee of medical specialists reviewed and certified case-specific cause of death. Scientific leadership was provided by NCI Project Officers, PLCO principal investigators, external consultants, and an independent data and safety monitoring board. PMID:26238115

  3. Screening Risk Evaluation methodology

    SciTech Connect

    Hopper, K.M.

    1994-06-01

    The Screening Risk Evaluation (SRE) Guidance document is a set of guidelines provided for the uniform implementation of SREs performed on D&D facilities. These guidelines are designed specifically for the completion of the second (semi-quantitative screening) phase of the D&D Risk-Based Process. The SRE Guidance produces screening risk scores reflecting levels of risk through the use of risk ranking indices. Five types of possible risk are calculated from the SRE: current releases, worker exposures, future releases, physical hazards, and criticality. The Current Release Index (CRI) calculates the risk to human health and the environment from ongoing or probable releases within a one year time period. The Worker Exposure Index (WEI) calculates the risk to workers, occupants, and visitors in D&D facilities of contaminant exposure. The Future Release Index (FRI) calculates the risk of future releases of contaminants, after one year, to human health and the environment. The Physical Hazards Index (PHI) calculates the risk-to human health due to factors other than that of contaminants. The index of Criticality is approached as a modifying factor to the entire SRE, due to the fact that criticality issues are strictly regulated under DOE. Screening risk results will be tabulated in matrix form and Total Risk will be calculated (weighted equation) to produce a score on which to base early action recommendations. Other recommendations from the screening risk scores will be made based either on individual index scores or from reweighted Total Risk calculations. All recommendations based on the SRE will be made based on a combination of screening risk scores, decision drivers, and other considerations, determined on a project by project basis. The SRE is the first and most important step in the overall D&D project level decision making process.

  4. 26 CFR 301.6323(d)-1 - 45-day period for making disbursements.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... disbursements has actual notice or knowledge of the tax lien filing, but only if the security interest is— (1... that the written agreement provides that the disbursements are to be made at the option of the person... circumstances under which a person is deemed to have actual notice or knowledge of a fact. (b) Examples....

  5. Lunar Dust Mitigation Screens

    NASA Astrophysics Data System (ADS)

    Knutson, Shawn; Holloway, Nancy

    With plans for the United States to return to the moon, and establish a sustainable human presence on the lunar surface many issues must be successfully overcome. Lunar dust is one of a number of issues with the potential to create a myriad of problems if not adequately addressed. Samples of dust brought back from Apollo missions show it to be soft, yet sharp and abrasive. The dust consists of a variety of morphologies including spherical, angular blocks, shards, and a number of irregular shapes. One of the main issues with lunar dust is its attraction to stick to anything it comes in contact with (i.e. astronauts, equipment, habitats, etc.). Ionized radiation from the sun strikes the moon's surface and creates an electrostatic charge on the dust. Further, the dust harbors van der Waals forces making it especially difficult to separate once it sticks to a surface. During the Apollo missions, it was discovered that trying to brush the lunar dust from spacesuits was not effective, and rubbing it caused degradation of the suit material. Further, when entering the lunar module after moonwalks, the astronauts noted that the dust was so prolific inside the cabin that they inhaled and ingested it, causing at least one of them, Harrison "Jack" Schmidt, to report irritation of the throat and lungs. It is speculated that the dust could also harm an astronaut's nervous and cardiovascular systems, especially during an extended stay. In addition to health issues, the dust can also cause problems by scouring reflective coatings off of thermal blankets, and roughening surfaces of windows and optics. Further, panels on solar cells and photovoltaics can also be compromised due to dust sticking on the surfaces. Lunar dust has the capacity to penetrate seals, interfere with connectors, as well as mechanisms on digging machines, all of which can lead to problems and failure. To address lunar dust issues, development of electrostatic screens to mitigate dust on sur-faces is currently

  6. Safety analysis

    NASA Technical Reports Server (NTRS)

    Knight, John C.

    1995-01-01

    We are engaged in a research program in safety-critical computing that is based on two case studies. We use these case studies to provide application-specific details of the various research issues, and as targets for evaluation of research ideas. The first case study is the Magnetic Stereotaxis System (MSS), an investigational device for performing human neurosurgery being developed in a joint effort between the Department of Physics at the University of Virginia and the Department of Neurosurgery at the University of Iowa. The system operates by manipulating a small permanent magnet (known as a 'seed') within the brain using an externally applied magnetic field. By varying the magnitude and gradient of the external magnetic field, the seed can be moved along a non-linear path and positioned at a site requiring therapy, e.g., a tumor. The magnetic field required for movement through brain tissue is extremely high, and is generated by a set of six superconducting magnets located in a housing surrounding the patient's head. The system uses two X-ray cameras positioned at right angles to detect in real time the locations of the seed and of X-ray opaque markers affixed to the patient's skull. the X-ray images are used to locate the objects of interest in a canonical frame of reference. the second case study is the University of Virginia Research Nuclear Reactor (UVAR). It is a 2 MW thermal, concrete-walled pool reactor. The system operates using 20 to 25 plate-type fuel assemblies placed on a rectangular grid plate. There are three scramable safety rods, and one non-scramable regulating rod that can be put in automatic mode. It was originally constructed in 1959 as a 1 MW system, and it was upgraded to 2 MW in 1973. Though only a research reactor rather than a power reactor, the issues raised are significant and can be related to the problems faced by full-scale reactor systems.

  7. HANFORD NUCLEAR CRITICALITY SAFETY PROGRAM DATABASE

    SciTech Connect

    TOFFER, H.

    2005-05-02

    The Hanford Database is a useful information retrieval tool for a criticality safety practitioner. The database contains nuclear criticality literature screened for parameter studies. The entries, characterized with a value index, are segregated into 16 major and six minor categories. A majority of the screened entries have abstracts and a limited number are connected to the Office of Scientific and Technology Information (OSTI) database of full-size documents. Simple and complex searches of the data can be accomplished very rapidly and the end-product of the searches could be a full-size document. The paper contains a description of the database, user instructions, and a number of examples.

  8. Rebuilding a safety culture

    NASA Astrophysics Data System (ADS)

    Rodney, George A.

    1991-11-01

    The development of a culture of safety and NASA since the Challenger accident is reviewed. The technical elements of the strengthened NASA safety program are described, including problem reporting, risk/assessment/risk management, operational safety, and safety assurance are addressed. Future directions in the development of safety are considered.

  9. Safety in the Workplace.

    ERIC Educational Resources Information Center

    Shaw, Richard

    1999-01-01

    Addresses workplace safety needs and tips for helping an organization achieve a high level of safety. Tips include showing administration commitment, establishing retribution-free reporting of safety problems and violations, rewarding excellent safety effort, and allowing no compromises in following safety procedures. (GR)

  10. Rebuilding a safety culture

    NASA Technical Reports Server (NTRS)

    Rodney, George A.

    1991-01-01

    The development of a culture of safety and NASA since the Challenger accident is reviewed. The technical elements of the strengthened NASA safety program are described, including problem reporting, risk/assessment/risk management, operational safety, and safety assurance are addressed. Future directions in the development of safety are considered.

  11. Attentional bias toward safety predicts safety behaviors.

    PubMed

    Xu, Yaoshan; Li, Yongjuan; Wang, Guangxi; Yuan, Xiao; Ding, Weidong; Shen, Zhongxiang

    2014-10-01

    Safety studies have primarily focused on how explicit processes and measures affect safety behavior and subsequent accidents and injuries. Recently, safety researchers have paid greater attention to the role of implicit processes. Our research focuses on the role of attentional bias toward safety (ABS) in workplace safety. ABS is a basic, early-stage cognitive process involving the automatic and selective allocation of attentional resources toward safety cues, which reflect the implicit motivational state of employees regarding safety goal. In this study, we used two reaction time-based paradigms to measure the ABS of employees in three studies: two modified Stroop tasks (Studies 1 and 2) and a visual dot-probe task (Study 3). Results revealed that employees with better safety behavior showed significant ABS (Study 2), and greater ABS than employees with poorer safety behavior (Studies 1 and 2). Moreover, ABS was positively associated with the perceived safety climate and safety motivation of employees, both of which mediate the effect of ABS on safety behavior (Study 3). These results contributed to a deeper understanding of how early-stage automatic perceptual processing affects safety behavior. The practical implications of these results were also discussed. PMID:24922613

  12. Screening for fetal aneuploidy.

    PubMed

    Rink, Britton D; Norton, Mary E

    2016-02-01

    Screening is currently recommended in pregnancy for a number of genetic disorders, chromosomal aneuploidy, and structural birth defects in the fetus regardless of maternal age or family history. There is an overwhelming array of sonographic and maternal serum-based options available for carrying out aneuploidy risk assessment in the first and/or second trimester. As with any screening test, the patient should be made aware that a "negative" test or "normal" ultrasound does not guarantee a healthy baby and a "positive" test does not mean the fetus has the condition. The woman should have both pre- and post-test counseling to discuss the benefits, limitations, and options for additional testing. Rapid advancements of genetic technologies have made it possible to screen for the common aneuploidies traditionally associated with advanced maternal age with improved levels of accuracy beyond serum and ultrasound based testing. Prenatal screening for fetal genetic disorders with cell-free DNA has transformed prenatal care with yet unanswered questions related to the financial, ethical, and appropriate application in the provision of prenatal risk assessment. PMID:26725144

  13. Early Dementia Screening.

    PubMed

    Panegyres, Peter K; Berry, Renee; Burchell, Jennifer

    2016-01-01

    As the population of the world increases, there will be larger numbers of people with dementia and an emerging need for prompt diagnosis and treatment. Early dementia screening is the process by which a patient who might be in the prodromal phases of a dementing illness is determined as having, or not having, the hallmarks of a neurodegenerative condition. The concepts of mild cognitive impairment, or mild neurocognitive disorder, are useful in analyzing the patient in the prodromal phase of a dementing disease; however, the transformation to dementia may be as low as 10% per annum. The search for early dementia requires a comprehensive clinical evaluation, cognitive assessment, determination of functional status, corroborative history and imaging (including MRI, FDG-PET and maybe amyloid PET), cerebrospinal fluid (CSF) examination assaying Aβ1-42, T-τ and P-τ might also be helpful. Primary care physicians are fundamental in the screening process and are vital in initiating specialist investigation and treatment. Early dementia screening is especially important in an age where there is a search for disease modifying therapies, where there is mounting evidence that treatment, if given early, might influence the natural history-hence the need for cost-effective screening measures for early dementia. PMID:26838803

  14. Visual Screening: A Procedure.

    ERIC Educational Resources Information Center

    Williams, Robert T.

    Vision is a complex process involving three phases: physical (acuity), physiological (integrative), and psychological (perceptual). Although these phases cannot be considered discrete, they provide the basis for the visual screening procedure used by the Reading Services of Colorado State University and described in this document. Ten tests are…

  15. Screens and Displays.

    ERIC Educational Resources Information Center

    Edstrom, Malin

    1987-01-01

    Discusses the characteristics of different computer screen technologies including the possible harmful effects on health of cathode ray tube (CRT) terminals. CRT's are compared to other technologies including liquid crystal displays, plasma displays, electroluminiscence displays, and light emitting diodes. A chart comparing the different…

  16. Early Dementia Screening

    PubMed Central

    Panegyres, Peter K.; Berry, Renee; Burchell, Jennifer

    2016-01-01

    As the population of the world increases, there will be larger numbers of people with dementia and an emerging need for prompt diagnosis and treatment. Early dementia screening is the process by which a patient who might be in the prodromal phases of a dementing illness is determined as having, or not having, the hallmarks of a neurodegenerative condition. The concepts of mild cognitive impairment, or mild neurocognitive disorder, are useful in analyzing the patient in the prodromal phase of a dementing disease; however, the transformation to dementia may be as low as 10% per annum. The search for early dementia requires a comprehensive clinical evaluation, cognitive assessment, determination of functional status, corroborative history and imaging (including MRI, FDG-PET and maybe amyloid PET), cerebrospinal fluid (CSF) examination assaying Aβ1–42, T-τ and P-τ might also be helpful. Primary care physicians are fundamental in the screening process and are vital in initiating specialist investigation and treatment. Early dementia screening is especially important in an age where there is a search for disease modifying therapies, where there is mounting evidence that treatment, if given early, might influence the natural history—hence the need for cost-effective screening measures for early dementia. PMID:26838803

  17. Screening for prostate cancer.

    PubMed Central

    Cher, M L; Carroll, P R

    1995-01-01

    Prostate cancer is a serious health care problem in the United States. Whether or not to screen for it has become a timely issue. Although a large number of men have clinically important, asymptomatic, undetected prostate cancer, an even larger number have clinically unimportant cancer. To justify screening programs, not only must we avoid detecting biologically unimportant cancers, we must also detect and effectively treat that subset of tumors that, if undiagnosed, would progress, produce symptoms, and reduce life expectancy. Serum prostate-specific antigen (PSA) assay, or its variations such as PSA density, PSA velocity, and age-specific reference ranges, and the digital rectal examination are the best tests for detecting clinically important, asymptomatic, curable tumors. Recent data suggest that using serum PSA levels does not result in an overdetection of unimportant tumors. Highly effective, curative treatment of localized prostate cancer is available. These factors promote optimism that screening for prostate cancer will ultimately prove beneficial. Nonetheless, men should be informed regarding the benefits and possible risks before being screened for prostate cancer. PMID:7536993

  18. Screening for hepatocellular carcinoma.

    PubMed

    Nguyen, Mindie H; Keeffe, Emmet B

    2002-01-01

    Hepatocellular carcinoma (HCC) is common throughout the world and most often develops as a late complication of chronic viral hepatitis or cirrhosis of any cause. As a result of the high prevalence rate of chronic hepatitis C, the incidence of HCC is rising in the United States, as well as in European and Asian countries. The overall survival rate of HCC is poor, and surgical resection and liver transplantation are the only curative treatment options. Screening for HCC offers the best hope for early detection, eligibility for treatment, and improved survival. Most physicians routinely screen at-risk patients with chronic viral hepatitis and cirrhosis for HCC, despite the lack of official guidelines. The current consensus recommendations are to screen healthy hepatitis B virus carriers with annual or semiannual serum alpha-fetoprotein; carriers with chronic hepatitis or cirrhosis and patients with cirrhosis of any etiology are surveyed with twice yearly serum alpha-fetoprotein and liver ultrasound. This article will review the current recommendations for HCC screening, the rationale that led to these recommendations, and the challenges of cost-effectiveness research in this area. PMID:12394211

  19. Afterword: "Screening Schoolhood"

    ERIC Educational Resources Information Center

    Howard, Jeremy

    2011-01-01

    "Screening schoolhood" attempts to move on both the debate and material covered by the six lead articles in this special issue. It appreciates the ways the articles, and the films they examine, deal with educational issues while at the same time evaluating their range in terms of creative construct and place in the history of documentary film.…

  20. Brassica greens herbicide screening

    Technology Transfer Automated Retrieval System (TEKTRAN)

    The objective of this study was to screen herbicides for potential use in brassica greens. Plots were in a RBD with 4 replications. The study was direct seeded on May 19, 2009 with a seeding rate of 272,000 seeds/acre (‘Savanna’ mustard). Treatments included trifluralin PPI + DCPA pre-emergence ap...

  1. An Innovative Multimedia Approach to Laboratory Safety

    NASA Technical Reports Server (NTRS)

    Anderson, M. B.; Constant, K. P.

    1996-01-01

    A new approach for teaching safe laboratory practices has been developed for materials science laboratories at Iowa State university. Students are required to complete a computerized safety tutorial and pass an exam before working in the laboratory. The safety tutorial includes sections on chemical, electrical, radiation, and high temperature safety. The tutorial makes use of a variety of interactions, including 'assembly' interactions where a student is asked to drag and drop items with the mouse (either labels or pictures) to an appropriate place on the screen (sometimes in a specific order). This is extremely useful for demonstrating safe lab practices and disaster scenarios. Built into the software is a record tracking scheme so that a professor can access a file that records which students have completed the tutorial and their scores on the exam. This paper will describe the development and assessment of the safety tutorials.

  2. PERFORMANCE DEMONSTRATIONS OF ALTERNATIVE SCREEN RECLAMATION PRODUCTS FOR SCREEN PRINTING

    EPA Science Inventory

    This project evaluated environmentally-preferable products for the screen reclamation process In screen printing during month-long demonstrations at 23 printing facilities nationwide. hrough the Environmental Protection Agency (EPA) Design for the Environment Printing Project, pr...

  3. Workplace Safety and Health Topics: Safety & Prevention

    MedlinePlus

    ... message, please visit this page: About CDC.gov . Workplace Safety and Health Topics Industries & Occupations Hazards & Exposures Diseases & ... Pinterest Twitter YouTube NIOSH Homepage NIOSH A-Z Workplace Safety & Health Topics Publications and Products Programs Contact NIOSH ...

  4. Food safety.

    PubMed

    Borchers, Andrea; Teuber, Suzanne S; Keen, Carl L; Gershwin, M Eric

    2010-10-01

    Food can never be entirely safe. Food safety is threatened by numerous pathogens that cause a variety of foodborne diseases, algal toxins that cause mostly acute disease, and fungal toxins that may be acutely toxic but may also have chronic sequelae, such as teratogenic, immunotoxic, nephrotoxic, and estrogenic effects. Perhaps more worrisome, the industrial activities of the last century and more have resulted in massive increases in our exposure to toxic metals such as lead, cadmium, mercury, and arsenic, which now are present in the entire food chain and exhibit various toxicities. Industrial processes also released chemicals that, although banned a long time ago, persist in the environment and contaminate our food. These include organochlorine compounds, such as 1,1,1-trichloro-2,2-bis(p-chlorophenyl)ethane (dichlorodiphenyl dichloroethene) (DDT), other pesticides, dioxins, and dioxin-like compounds. DDT and its breakdown product dichlorophenyl dichloroethylene affect the developing male and female reproductive organs. In addition, there is increasing evidence that they exhibit neurodevelopmental toxicities in human infants and children. They share this characteristic with the dioxins and dioxin-like compounds. Other food contaminants can arise from the treatment of animals with veterinary drugs or the spraying of food crops, which may leave residues. Among the pesticides applied to food crops, the organophosphates have been the focus of much regulatory attention because there is growing evidence that they, too, affect the developing brain. Numerous chemical contaminants are formed during the processing and cooking of foods. Many of them are known or suspected carcinogens. Other food contaminants leach from the packaging or storage containers. Examples that have garnered increasing attention in recent years are phthalates, which have been shown to induce malformations in the male reproductive system in laboratory animals, and bisphenol A, which negatively

  5. Bromine Safety

    SciTech Connect

    Meyers, B

    2001-04-09

    The production and handling in 1999 of about 200 million kilograms of bromine plus substantial derivatives thereof by Great Lakes Chemical Corp. and Albemarle Corporation in their southern Arkansas refineries gave OSHA Occupational Injury/Illness Rates (OIIR) in the range of 0.74 to 1.60 reportable OIIRs per 200,000 man hours. OIIRs for similar industries and a wide selection of other U.S. industries range from 1.6 to 23.9 in the most recent OSHA report. Occupational fatalities for the two companies in 1999 were zero compared to a range in the U.S.of zero for all computer manufacturing to 0.0445 percent for all of agriculture, forestry and fishing in the most recent OSHA report. These results show that bromine and its compounds can be considered as safe chemicals as a result of the bromine safety standards and practices at the two companies. The use of hydrobromic acid as an electrical energy storage medium in reversible PEM fuel cells is discussed. A study in 1979 of 20 megawatt halogen working fluid power plants by Oronzio de Nora Group found such energy to cost 2 to 2.5 times the prevailing base rate at that time. New conditions may reduce this relative cost. The energy storage aspect allows energy delivery at maximum demand times where the energy commands premium rates. The study also found marginal cost and performance advantages for hydrobromic acid over hydrochloric acid working fluid. Separate studies in the late 70s by General Electric also showed marginal performance advantages for hydrobromic acid.

  6. An Alternative to Impedance Screening: Unoccluded Frontal Bone Conduction Screening.

    ERIC Educational Resources Information Center

    Square, Regina; And Others

    1985-01-01

    A bone conduction hearing screening test using frontal bone oscillator placement was compared with pure-tone air-conduction screening and impedance audiometry with 114 preschoolers. Unoccluded frontal bone conduction testing produced screening results not significantly different from results obtained by impedance audiometry. (CL)!

  7. Seismic Safety Study

    SciTech Connect

    Tokarz, F J; Coats, D W

    2006-05-16

    During the past three decades, the Laboratory has been proactive in providing a seismically safe working environment for its employees and the general public. Completed seismic upgrades during this period have exceeded $30M with over 24 buildings structurally upgraded. Nevertheless, seismic questions still frequently arise regarding the safety of existing buildings. To address these issues, a comprehensive study was undertaken to develop an improved understanding of the seismic integrity of the Laboratory's entire building inventory at the Livermore Main Site and Site 300. The completed study of February 2005 extended the results from the 1998 seismic safety study per Presidential Executive Order 12941, which required each federal agency to develop an inventory of its buildings and to estimate the cost of mitigating unacceptable seismic risks. Degenkolb Engineers, who performed the first study, was recontracted to perform structural evaluations, rank order the buildings based on their level of seismic deficiencies, and to develop conceptual rehabilitation schemes for the most seriously deficient buildings. Their evaluation is based on screening procedures and guidelines as established by the Interagency Committee on Seismic Safety in Construction (ICSSC). Currently, there is an inventory of 635 buildings in the Laboratory's Facility Information Management System's (FIMS's) database, out of which 58 buildings were identified by Degenkolb Engineers that require seismic rehabilitation. The remaining 577 buildings were judged to be adequate from a seismic safety viewpoint. The basis for these evaluations followed the seismic safety performance objectives of DOE standard (DOE STD 1020) Performance Category 1 (PC1). The 58 buildings were ranked according to three risk-based priority classifications (A, B, and C) as shown in Figure 1-1 (all 58 buildings have structural deficiencies). Table 1-1 provides a brief description of their expected performance and damage state

  8. Nuclear criticality safety guide

    SciTech Connect

    Pruvost, N.L.; Paxton, H.C.

    1996-09-01

    This technical reference document cites information related to nuclear criticality safety principles, experience, and practice. The document also provides general guidance for criticality safety personnel and regulators.

  9. Farm Health and Safety

    MedlinePlus

    ... jobs in the United States. Farms have many health and safety hazards, including Chemicals and pesticides Machinery, ... equipment can also reduce accidents. Occupational Safety and Health Administration

  10. Medical Device Safety

    MedlinePlus

    ... Vaccines, Blood & Biologics Animal & Veterinary Cosmetics Tobacco Products Medical Devices Home Medical Devices Medical Device Safety Medical Device Safety Share Tweet Linkedin Pin it More sharing ...

  11. Screening for Carotid Artery Stenosis

    MedlinePlus

    ... Task Force learned about the potential benefits and harms of screening for carotid artery stenosis: Health professionals ... blood flow through the arteries. Potential Benefits and Harms of Carotid Artery Stenosis Screening and Treatment The ...

  12. Screening for Abdominal Aortic Aneurysm

    MedlinePlus

    Understanding Task Force Recommendations Screening for Abdominal Aortic Aneurysm The U.S. Preventive Services Task Force (Task Force) ... final recommendation statement on Screening for Abdominal Aortic Aneurysm. This final recommendation statement applies to adults ages ...

  13. Recommended Screenings for Men 50+

    MedlinePlus

    ... and continue reading about other screenings. Abdominal Aortic Aneurysm If you are between the ages of 65 ... care team about being screened for abdominal aortic aneurysm (AAA). AAA is a bulging in your abdominal ...

  14. Save Babies through Screening Foundation

    MedlinePlus

    ... screenable disorders. More Practitioners Save Babies Videos Newborn screening saves babies, one foot at a time. For ... disease that could have been treated had newborn screening taken place before the baby left the hospital. ...

  15. Developments in Colorectal Cancer Screening

    MedlinePlus

    ... on. Feature: Colorectal Cancer Developments in Colorectal Cancer Screening Summer 2016 Table of Contents Dr. Asad Umar, ... know to help determine the best colon cancer screening test for them? Colonoscopy is considered the gold ...

  16. National Lung Screening Trial (NLST)

    Cancer.gov

    The National Lung Screening Trial (NLST), a research study sponsored by the National Cancer Institute that used low-dose helical CT scans or chest X-ray to screen men and women at risk for lung cancer.

  17. Second Trimester Maternal Serum Screening

    MedlinePlus

    ... Screen Related tests: hCG Pregnancy ; Estrogens ; First Trimester Down Syndrome Screen ; Amniotic Fluid Analysis ; Chromosome Analysis Were you ... that a fetus has certain chromosomal abnormalities, including Down syndrome (trisomy 21) or Edwards syndrome (trisomy 18) , or ...

  18. Safety Assurance in Obstetrical Ultrasound

    PubMed Central

    Miller, Douglas L

    2008-01-01

    Safety assurance for diagnostic ultrasound in obstetrics began with a tacit assumption of safety allowed by a federal law enacted in 1976 for then-existing medical ultrasound equipment. The implementation of the 510(k) pre-market approval process for diagnostic ultrasound resulted in the establishment of guideline upper limits for several examination categories in 1985. The obstetrical category has undergone substantial evolution from initial limits (I. e., 46 mW/cm2 spatial peak temporal average (SPTA) intensity) set in 1985. Thermal and mechanical exposure indices, which are displayed on-screen according to an Output Display Standard (ODS), were developed for safety assurance with relaxed upper limits. In 1992, with the adoption of the ODS, the allowable output for obstetrical ultrasound was increased both in terms of the average exposure (e. g. to a possible 720 mW/cm2 SPTA intensity) and of the peak exposure (via the Mechanical Index). There has been little or no subsequent research with the modern obstetrical ultrasound machines to systematically assess potential risks to the fetus using either relevant animal models of obstetrical exposure or human epidemiology studies. The assurance of safety for obstetrical ultrasound therefore is supported by three ongoing means: (I) review of a substantial but uncoordinated bioeffect research literature, (ii) the theoretical evaluation of diagnostic ultrasound exposure in terms of thermal and nonthermal mechanisms for bioeffects, and (iii) the skill and knowledge of professional sonographers. At this time, there is no specific reason to suspect that there is any significant health risk to the fetus or mother from exposure to diagnostic ultrasound in obstetrics. This assurance of safety supports the prudent use of diagnostic ultrasound in obstetrics by trained professionals for any medically indicated examination. PMID:18450141

  19. [Chemical databases and virtual screening].

    PubMed

    Rognan, Didier; Bonnet, Pascal

    2014-12-01

    A prerequisite to any virtual screening is the definition of compound libraries to be screened. As we describe here, various sources are available. The selection of the proper library is usually project-dependent but at least as important as the screening method itself. This review details the main compound libraries that are available for virtual screening and guide the reader to the best possible selection according to its needs. PMID:25537046

  20. Automated macromolecular crystallization screening

    DOEpatents

    Segelke, Brent W.; Rupp, Bernhard; Krupka, Heike I.

    2005-03-01

    An automated macromolecular crystallization screening system wherein a multiplicity of reagent mixes are produced. A multiplicity of analysis plates is produced utilizing the reagent mixes combined with a sample. The analysis plates are incubated to promote growth of crystals. Images of the crystals are made. The images are analyzed with regard to suitability of the crystals for analysis by x-ray crystallography. A design of reagent mixes is produced based upon the expected suitability of the crystals for analysis by x-ray crystallography. A second multiplicity of mixes of the reagent components is produced utilizing the design and a second multiplicity of reagent mixes is used for a second round of automated macromolecular crystallization screening. In one embodiment the multiplicity of reagent mixes are produced by a random selection of reagent components.

  1. Impedimetric screening for bacteriuria.

    PubMed Central

    Cady, P; Dufour, S W; Lawless, P; Nunke, B; Kraeger, S J

    1978-01-01

    A rapid, automated instrumental procedure for distinguishing urine cultures containing greater than 10(5) organism per ml is described. The method is based upon the measurement of changes in impedance that take place as microorganisms alter the chemical composition of the medium. The time required to detect impedance change is inversely related to the initial concentration of microorganisms in the sample. By defining an impedance-positive culture as one that gives detectable impedance change within 2.6 h, 95.8% of 1,133 urine cultures tested were correctly classified as containing more than or fewer than 10(5) organisms per ml. Selection of a longer detection time decreases false negative results at the cost of increased false positive results. Impedance screening is compared with screening data reported in the literature using adenosine-5'-triphosphate detection, microcalorimetry, electrochemical measurements, and optical microscopy. Images PMID:348719

  2. [Screening for prostate cancer].

    PubMed

    Koch, Klaus; Büchter, Roland; Lange, Stefan

    2013-04-01

    Prostate cancer screening has been a controversial for decades. The recently published findings of large trials have further intensified the debate. The prospect of reducing mortality from prostate cancer is measured against the risk of over-diagnosing the disease. In individual cases, the trade-off between possible benefits and harms is possible to ascertain, so general recommendations in favor of or against PSA tests for individuals cannot be made. The majority of men, however, are not well-informed on the possible advantages and drawbacks of screening. This situation urgently needs to be corrected. The PSA test is promoted to healthy men, who need to be provided with especially detailed information. If not provided with clear and unbiased information on the risks associated with the test (above all over-diagnosis and over-treatment), these men cannot be considered to be fully informed. PMID:23535548

  3. Rapid, Optimized Interactomic Screening

    PubMed Central

    Hakhverdyan, Zhanna; Domanski, Michal; Hough, Loren; Oroskar, Asha A.; Oroskar, Anil R.; Keegan, Sarah; Dilworth, David J.; Molloy, Kelly R.; Sherman, Vadim; Aitchison, John D.; Fenyö, David; Chait, Brian T.; Jensen, Torben Heick; Rout, Michael P.; LaCava, John

    2015-01-01

    We must reliably map the interactomes of cellular macromolecular complexes in order to fully explore and understand biological systems. However, there are no methods to accurately predict how to capture a given macromolecular complex with its physiological binding partners. Here, we present a screen that comprehensively explores the parameters affecting the stability of interactions in affinity-captured complexes, enabling the discovery of physiological binding partners and the elucidation of their functional interactions in unparalleled detail. We have implemented this screen on several macromolecular complexes from a variety of organisms, revealing novel profiles even for well-studied proteins. Our approach is robust, economical and automatable, providing an inroad to the rigorous, systematic dissection of cellular interactomes. PMID:25938370

  4. [Primary cervical cancer screening].

    PubMed

    Vargas-Hernández, Víctor Manuel; Vargas-Aguilar, Víctor Manuel; Tovar-Rodríguez, José María

    2015-01-01

    Cervico-uterine cancer screening with cytology decrease incidence by more than 50%. The cause of this cancer is the human papilloma virus high risk, and requires a sensitive test to provide sufficient sensitivity and specificity for early detection and greater interval period when the results are negative. The test of the human papilloma virus high risk, is effective and safe because of its excellent sensitivity, negative predictive value and optimal reproducibility, especially when combined with liquid-based cytology or biomarkers with viral load, with higher sensitivity and specificity, by reducing false positives for the detection of cervical intraepithelial neoplasia grade 2 or greater injury, with excellent clinical benefits to cervical cancer screening and related infection of human papilloma virus diseases, is currently the best test for early detection infection of human papillomavirus and the risk of carcinogenesis. PMID:26162490

  5. Updating Technical Screens for PV Interconnection: Preprint

    SciTech Connect

    Coddington, M.; Ellis, A.; Lynn, K.; Razon, A.; Key, T.; Kroposki, B.; Mather, B.; Hill, R.; Nicole, K.; Smith, J.

    2012-08-01

    Solar photovoltaics (PV) is the dominant type of distributed generation (DG) technology interconnected to electric distribution systems in the United States, and deployment of PV systems continues to increase rapidly. Considering the rapid growth and widespread deployment of PV systems in United States electric distribution grids, it is important that interconnection procedures be as streamlined as possible to avoid unnecessary interconnection studies, costs, and delays. Because many PV interconnection applications involve high penetration scenarios, the process needs to allow for a sufficiently rigorous technical evaluation to identify and address possible system impacts. Existing interconnection procedures are designed to balance the need for efficiency and technical rigor for all DG. However, there is an implicit expectation that those procedures will be updated over time in order to remain relevant with respect to evolving standards, technology, and practical experience. Modifications to interconnection screens and procedures must focus on maintaining or improving safety and reliability, as well as accurately allocating costs and improving expediency of the interconnection process. This paper evaluates the origins and usefulness of the capacity penetration screen, offers potential short-term solutions which could effectively allow fast-track interconnection to many PV system applications, and considers longer-term solutions for increasing PV deployment levels in a safe and reliable manner while reducing or eliminating the emphasis on the penetration screen.

  6. Mental Health Screening in Schools

    ERIC Educational Resources Information Center

    Weist, Mark D.; Rubin, Marcia; Moore, Elizabeth; Adelsheim, Steven; Wrobel, Gordon

    2007-01-01

    Background: This article discusses the importance of screening students in schools for emotional/behavioral problems. Methods: Elements relevant to planning and implementing effective mental health screening in schools are considered. Screening in schools is linked to a broader national agenda to improve the mental health of children and…

  7. What Screening Tests Are There?

    MedlinePlus

    ... Research Related Links Stay Informed Cancer Home What Screening Tests Are There? Language: English Español (Spanish) Recommend ... packs a day for 15 years. Risks of Screening Lung cancer screening has at least three risks— ...

  8. What's New with Newborn Screening

    ERIC Educational Resources Information Center

    Exceptional Parent, 2008

    2008-01-01

    Newborn screening is the process of testing and screening newborns shortly after birth for certain, potentially dangerous, conditions and/or impairments--conditions that include everything from inborn errors of metabolism and other genetic disorders to hearing impairment. Early detection through newborn screening is paramount, often allowing the…

  9. Lung Cancer Screening Recommendation Questioned.

    PubMed

    2016-06-01

    According to a retrospective analysis of data from the National Lung Screening Trial, participants with a history of heavy smoking who test negative for abnormalities suggestive of lung cancer on an initial low-dose CT screen may not need yearly CT scans. Instead, they could work with their doctors to devise an appropriate screening schedule based on individual risk factors. PMID:27076372

  10. Perioperative Troponin Screening.

    PubMed

    Sessler, Daniel I; Devereaux, P J

    2016-08-01

    Myocardial injury is the most common cause of death during the 30 days after noncardiac surgery. Only 14% of patients who are experiencing a perioperative myocardial infarction will have chest pain, and 65% are entirely clinically silent, which means that they will go undetected without routine troponin screening. Although it is tempting to dismiss asymptomatic troponin elevation, mortality is similar with and without symptoms. Furthermore, mortality at 30 days in patients who have postoperative troponin elevation is a concerning 10%, which represents a 5-fold increase from background risk. Among inpatients ≥45 years of age who are having noncardiac surgery, the number necessary to screen to detect myocardial injury after noncardiac surgery, that would otherwise be missed, is only about 15 patients. Thus, troponin screening seems appropriate for most surgical inpatients who are ≥45 years of age. Potential acute interventions include initiating therapy such as aspirin, statins, and angiotensin-converting enzyme (ACE) inhibitor antihypertensives, along with chronic lifestyle improvements such as smoking cessation, healthful eating, and exercise. PMID:27331782

  11. Weak bond screening system

    NASA Astrophysics Data System (ADS)

    Chuang, S. Y.; Chang, F. H.; Bell, J. R.

    Consideration is given to the development of a weak bond screening system which is based on the utilization of a high power ultrasonic (HPU) technique. The instrumentation of the prototype bond strength screening system is described, and the adhesively bonded specimens used in the system developmental effort are detailed. Test results obtained from these specimens are presented in terms of bond strength and level of high power ultrasound irradiation. The following observations were made: (1) for Al/Al specimens, 2.6 sec of HPU irradiation will screen weak bond conditions due to improper preparation of bonding surfaces; (2) for composite/composite specimens, 2.0 sec of HPU irradiation will disrupt weak bonds due to under-cured conditions; (3) for Al honeycomb core with composite skin structure, 3.5 sec of HPU irradiation will disrupt weak bonds due to bad adhesive or oils contamination of bonding surfaces; and (4) for Nomex honeycomb with Al skin structure, 1.3 sec of HPU irradiation will disrupt weak bonds due to bad adhesive.

  12. Screening Resonances In Plasmas

    SciTech Connect

    Winkler, P.

    1998-12-01

    When it was suggested that a new recombination mechanism (Resonant Radiative Recombination (RRR)) which, based on very general physical arguments, should happen in dense plasmas and promises to provide useful information for the local temperature and density diagnostics of plasmas, they assumed the existence of screening resonances. For model potentials the existence of screening resonances has been demonstrated beyond reasonable doubt in a number of calculations. The key question, how well those potentials describe the dominant effects of a real plasma remains open. The relation of theoretical predictions to experimentally measurable effects is an important issue at the present stage of their research. In particular, RRR is expected to account for enhanced recombination rates of low energetic electrons with their ions, since the first stage is the resonant capture of a slow electron by an atom or ion. The mechanism that traps an electron is a combination of complicated many-body interactions of the ions and electrons. For clarity they start here, however, with a discussion in terms of local potential traps the shapes of which are determined predominantly and in an average way by two factors: the degree of screening present at the ionic site and the degree of short-range order in the immediate neighborhood of this ion.

  13. Screening botanical extracts for quinoid metabolites.

    PubMed

    Johnson, B M; Bolton, J L; van Breemen, R B

    2001-11-01

    Botanical dietary supplements represent a significant share of the growing market for alternative medicine in the USA, where current regulations do not require assessment of their safety. To help ensure the safety of such products, an in vitro assay using pulsed ultrafiltration and LC-MS-MS has been developed to screen botanical extracts for the formation of electrophilic and potentially toxic quinoid species upon bioactivation by hepatic cytochromes P450. Rat liver microsomes were trapped in a flow-through chamber by an ultrafiltration membrane, and samples containing botanical extracts, GSH and NADP(H), were flow-injected into the chamber. Botanical compounds that were metabolized to reactive intermediates formed stable GSH adducts mimicking a common in vivo detoxification pathway. If present in the ultrafiltrate, GSH conjugates were detected using LC-MS-MS with precursor ion scanning followed by additional characterization using product ion scanning and comparison to standard compounds. As expected, no GSH adducts of reactive metabolites were found in extracts of Trifolium pratense L. (red clover), which are under investigation as botanical dietary supplements for the management of menopause. However, extracts of Sassafras albidum (Nutt.) Nees (sassafras), Symphytum officinale L. (comfrey), and Rosmarinus officinalis L. (rosemary), all of which are known to contain compounds that are either carcinogenic or toxic to mammals, produced GSH adducts during this screening assay. Several compounds that formed GSH conjugates including novel metabolites of rosmarinic acid were identified using database searching and additional LC-MS-MS studies. This assay should be useful as a preliminary toxicity screen during the development of botanical dietary supplements. A positive test suggests that additional toxicological studies are warranted before human consumption of a botanical product. PMID:11712913

  14. Neonatal Screening Part 2: Neonatal Screening in Canada

    PubMed Central

    Morris, Brian A.P.

    1990-01-01

    Neonatal screening is a widely accepted, cost-effective method for early detection of various inborn errors of metabolism. This series of three articles examines different aspects of neonatal screening. In the first article, the author discussed general principles of screening and its function in the spectrum of diagnostic techniques for genetic disease. In this, the second article, the author reviews the history and current practices of neonatal screening in Canada. The individual diseases for which screening is used and particular points of interest for each of these diseases are briefly described. The author also outlines the benefits of screening and treatment. In the final article of this series, the author will examine controversial topics that represent the possible future of screening. PMID:21234041

  15. Virtual screening of chemical libraries

    PubMed Central

    Shoichet, Brian K.

    2005-01-01

    Virtual screening uses computer-based methods to discover new ligands on the basis of biological structures. Although widely heralded in the 1970s and 1980s, the technique has since struggled to meet its initial promise, and drug discovery remains dominated by empirical screening. Recent successes in predicting new ligands and their receptor-bound structures, and better rates of ligand discovery compared to empirical screening, have re-ignited interest in virtual screening, which is now widely used in drug discovery, albeit on a more limited scale than empirical screening. PMID:15602552

  16. Wicking of liquids in screens

    NASA Technical Reports Server (NTRS)

    Symons, E. P.

    1974-01-01

    An investigation was conducted to determine the magnitude of the wicking rates of liquids in various screens. Evaluation of the parameters characterizing the wicking process resulted in the development of an expression which defined the wicking velocity in terms of screen and system geometry, liquid properties, and gravitational effects. Experiment data obtained both in normal gravity and in weightlessness demonstrated that the model successfully predicted the functional relation of the liquid properties and the distance from the liquid source to the wicking velocity. Because the pore geometry in the screens was complex, several screen geometric parameters were lumped into a single constant which was determined experimentally for each screen.

  17. Safety: An Attitude

    ERIC Educational Resources Information Center

    Smith, Harry T.

    1978-01-01

    Describes eight safety concepts developed by the author to teach safety and accident prevention in industrial arts shops and to promote more positive student attitudes toward shop safety. Stressing several general safety concepts instead of requiring dozens of rules has been found to work. (MF)

  18. Nuclear Powerplant Safety: Operations.

    ERIC Educational Resources Information Center

    Department of Energy, Washington, DC. Nuclear Energy Office.

    Powerplant systems and procedures that ensure the day-to-day health and safety of people in and around the plant is referred to as operational safety. This safety is the result of careful planning, good engineering and design, strict licensing and regulation, and environmental monitoring. Procedures that assure operational safety at nuclear…

  19. Root Cause Analysis: Learning from Adverse Safety Events.

    PubMed

    Brook, Olga R; Kruskal, Jonathan B; Eisenberg, Ronald L; Larson, David B

    2015-10-01

    Serious adverse events continue to occur in clinical practice, despite our best preventive efforts. It is essential that radiologists, both as individuals and as a part of organizations, learn from such events and make appropriate changes to decrease the likelihood that such events will recur. Root cause analysis (RCA) is a process to (a) identify factors that underlie variation in performance or that predispose an event toward undesired outcomes and (b) allow for development of effective strategies to decrease the likelihood of similar adverse events occurring in the future. An RCA process should be performed within the environment of a culture of safety, focusing on underlying system contributors and, in a confidential manner, taking into account the emotional effects on the staff involved. The Joint Commission now requires that a credible RCA be performed within 45 days for all sentinel or major adverse events, emphasizing the need for all radiologists to understand the processes with which an effective RCA can be performed. Several RCA-related tools that have been found to be useful in the radiology setting include the "five whys" approach to determine causation; cause-and-effect, or Ishikawa, diagrams; causal tree mapping; affinity diagrams; and Pareto charts. PMID:26466177

  20. Launch Services Safety Overview

    NASA Technical Reports Server (NTRS)

    Loftin, Charles E.

    2008-01-01

    NASA/KSC Launch Services Division Safety (SA-D) services include: (1) Assessing the safety of the launch vehicle (2) Assessing the safety of NASA ELV spacecraft (S/C) / launch vehicle (LV) interfaces (3) Assessing the safety of spacecraft processing to ensure resource protection of: - KSC facilities - KSC VAFB facilities - KSC controlled property - Other NASA assets (4) NASA personnel safety (5) Interfacing with payload organizations to review spacecraft for adequate safety implementation and compliance for integrated activities (6) Assisting in the integration of safety activities between the payload, launch vehicle, and processing facilities

  1. Safety signal detection: the relevance of literature review.

    PubMed

    Pontes, Helena; Clément, Mallorie; Rollason, Victoria

    2014-07-01

    Adverse drug reactions (ADRs) represent an important risk for patients and have a significant economic impact on health systems. ADRs are the fifth most common cause of hospital death, with a burden estimated at 197,000 deaths per year in the EU. This has a societal cost of 79 billion per year. Because of this strong impact in public health, regulatory authorities (RAs) worldwide are implementing new pharmacovigilance legislation to promote and protect public health by reducing the burden of ADRs through the detection of safety signals. Although, traditionally, signal detection activities have mainly been performed based on spontaneous reporting from healthcare professionals and national health RAs, the new pharmacovigilance legislation underlines the relevance of other sources of information (such as scientific literature) for the evaluation of the benefit-risk balance of a certain product. This review aims to highlight the relevance of periodic scientific literature screening in the safety signal detection process. The authors present four practical examples where a safety signal that was detected from a literature report had an impact on the lifecycle of a drug. In addition, based on practical experience of the screening of medical and scientific literature for safety purposes, this article analyses the requirements of the new pharmacovigilance guidelines on literature screening and highlights the need for the implementation of a literature review procedure and the main challenges encountered when performing literature screening for safety aspects. PMID:24895178

  2. Smart Screening System (S3) In Taconite Processing

    SciTech Connect

    Daryoush Allaei; Asim Syed Mohammed; David Tarnowski; Angus Morison

    2005-03-01

    The conventional screening machines used in processing plants have had undesirable high noise and vibration levels. They also have had unsatisfactorily low screening efficiency, high energy consumption, high maintenance cost, low productivity, and poor worker safety. These conventional vibrating machines have been used in almost every processing plant. Most of the current material separation technology uses heavy and inefficient electric motors with an unbalanced rotating mass to generate the shaking. In addition to being excessively noisy, inefficient, and high-maintenance, these vibrating machines are often the bottleneck in the entire process. Furthermore, these motors, along with the vibrating machines and supporting structure, shake other machines and structures in the vicinity. The latter increases maintenance costs while reducing worker health and safety. The conventional vibrating fine screens at taconite processing plants have had the same problems as those listed above. This has resulted in lower screening efficiency, higher energy and maintenance cost, and lower productivity and workers safety concerns. The focus of this work is on the design of a high performance screening machine suitable for taconite processing plants. SmartScreens{trademark} technology uses miniaturized motors, based on smart materials, to generate the shaking. The underlying technologies are Energy Flow Control{trademark} and Vibration Control by Confinement{trademark}. These concepts are used to direct energy flow and confine energy efficiently and effectively to the screen function. The SmartScreens{trademark} technology addresses problems related to noise and vibration, screening efficiency, productivity, and maintenance cost and worker safety. Successful development of SmartScreens{trademark} technology will bring drastic changes to the screening and physical separation industry. The final designs for key components of the SmartScreens{trademark} have been developed. The key

  3. Manufactured soil screening test

    SciTech Connect

    1999-05-01

    The purpose of this technical note is to provide a screening test that can be used to evaluate the potential for manufacturing artificial soil using dredged material, cellulose waste materials (e.g., yard waste compost, sawdust, wastepaper), and biosolids (e.g., N-Viro-reconditioned sewage sludge, BIONSOIL-reconstituted cow manure). This procedure will allow the most productive blend of any dredged material (uncontaminated or contaminated), cellulose, and biosolids to be determined and recommended for use in an environmentally productive and beneficial manner.

  4. Asbestos screening process

    SciTech Connect

    1994-07-01

    The paper discusses and demonstrates a simple asbestos screening test developed by Kupel and Kim. Standard tests to determine asbestos content in building materials cost up to $500.00 to perform. With 2 simple tests and kit devised by two men, anyone can perform these tests that now cost 25 cents each. And they are accurate. If positive results are obtained, the materials are sent to the lab for analysis. The two tests consist of use of acids, bases and reagents to test for iron and manganese content.

  5. Bioaffinity Mass Spectrometry Screening.

    PubMed

    Yang, Ben; Feng, Yun Jiang; Vu, Hoan; McCormick, Brendan; Rowley, Jessica; Pedro, Liliana; Crowther, Gregory J; Van Voorhis, Wesley C; Forster, Paul I; Quinn, Ronald J

    2016-02-01

    Electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI-FTICR-MS or ESI-FTMS) was used to screen 192 natural product extracts and a 659-member natural product-based fragment library for bindings to a potential malaria drug target, Plasmodium falciparum Rab11a (PfRab11a, PF13_0119). One natural product extract and 11 fragments showed binding activity. A new natural product, arborside E, was identified from the active extract of Psydrax montigena as a weak binder. Its binding activity and inhibitory activity against PfRab11a were confirmed by ESI-FTMS titration experiments and an orthogonal enzyme assay. PMID:26773071

  6. To screen or not to screen: What factors influence complex screening decisions?

    PubMed

    Petrova, Dafina; Garcia-Retamero, Rocio; Catena, Andrés; van der Pligt, Joop

    2016-06-01

    Contrary to people's intuitions, many screenings can have both benefits (e.g., lives saved) and harms (e.g., unnecessary treatments). Statistical information is often provided to ensure informed decision making. However, few theoretical models have addressed the role of comprehension of such information in screening decisions. In an experiment, we studied how cognitive skills, emotions, and a priori beliefs about screening affect comprehension of the evidence of benefits and harms from screening and intentions to get screened. Young adults (N = 347) received information about a disease for which a screening test was available and numerical information about the benefits and harms from screening. Results showed that comprehension and perceptions of benefits are central to decisions; however, lay perceptions of harms along the screening cascade require further study. Numeracy, science literacy, and emotions can promote informed decision making by facilitating comprehension of the evidence. At the same time emotions and beliefs resulting from persuasive campaigns can have strong effects on screening intentions beyond the available evidence. To apply to screening procedures where informed decision making is recommended, theoretical models of screening decisions need to include comprehension of benefits and harms, and account for how cognitive skills, emotions, and beliefs influence comprehension and decisions. (PsycINFO Database Record PMID:27295468

  7. TWRS safety program plan

    SciTech Connect

    Calderon, L.M., Westinghouse Hanford

    1996-08-01

    Management of Nuclear Safety, Industrial Safety, Industrial Hygiene, and Fire Protection programs, functions, and field support resources for Tank Waste Remediation Systems (TWRS) has, until recently, been centralized in TWRS Safety, under the Emergency, Safety, and Quality organization. Industrial hygiene technician services were also provided to support operational needs related to safety basis compliance. Due to WHC decentralization of safety and reengineering efforts in West Tank Farms, staffing and safety responsibilities have been transferred to the facilities. Under the new structure, safety personnel for TWRS are assigned directly to East Tank Farms, West Tank Farms, and a core Safety Group in TWRS Engineering. The Characterization Project Operations (CPO) safety organization will remain in tact as it currently exists. Personnel assigned to East Tank Farms, West Tank Farms, and CPO will perform facility-specific or project-specific duties and provide field implementation of programs. Those assigned to the core group will focus on activities having a TWRS-wide or programmatic focus. Hanford-wide activities will be the responsibility of the Safety Center of Expertise. In order to ensure an effective and consistent safety program for TWRS under the new organization program functions, goals, organizational structure, roles, responsibilities, and path forward must be clearly established. The purpose of the TWRS Safety Program Plan is to define the overall safety program, responsibilities, relationships, and communication linkages for safety personnel under the new structure. In addition, issues associated with reorganization transition are addressed, including training, project ownership, records management, and dissemination of equipment. For the purpose of this document ``TWRS Safety`` refers to all safety professionals and technicians (Industrial Safety, Industrial Hygiene, Fire Protection, and Nuclear Safety) within the TWRS organization, regardless of their

  8. INDUSTRIAL/MILITARY ACTIVITY-INITIATED ACCIDENT SCREENING ANALYSIS

    SciTech Connect

    D.A. Kalinich

    1999-09-27

    Impacts due to nearby installations and operations were determined in the Preliminary MGDS Hazards Analysis (CRWMS M&O 1996) to be potentially applicable to the proposed repository at Yucca Mountain. This determination was conservatively based on limited knowledge of the potential activities ongoing on or off the Nevada Test Site (NTS). It is intended that the Industrial/Military Activity-Initiated Accident Screening Analysis provided herein will meet the requirements of the ''Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants'' (NRC 1987) in establishing whether this external event can be screened from further consideration or must be included as a design basis event (DBE) in the development of accident scenarios for the Monitored Geologic Repository (MGR). This analysis only considers issues related to preclosure radiological safety. Issues important to waste isolation as related to impact from nearby installations will be covered in the MGR performance assessment.

  9. Allergic sensitization: screening methods.

    PubMed

    Ladics, Gregory S; Fry, Jeremy; Goodman, Richard; Herouet-Guicheney, Corinne; Hoffmann-Sommergruber, Karin; Madsen, Charlotte B; Penninks, André; Pomés, Anna; Roggen, Erwin L; Smit, Joost; Wal, Jean-Michel

    2014-01-01

    Experimental in silico, in vitro, and rodent models for screening and predicting protein sensitizing potential are discussed, including whether there is evidence of new sensitizations and allergies since the introduction of genetically modified crops in 1996, the importance of linear versus conformational epitopes, and protein families that become allergens. Some common challenges for predicting protein sensitization are addressed: (a) exposure routes; (b) frequency and dose of exposure; (c) dose-response relationships; (d) role of digestion, food processing, and the food matrix; (e) role of infection; (f) role of the gut microbiota; (g) influence of the structure and physicochemical properties of the protein; and (h) the genetic background and physiology of consumers. The consensus view is that sensitization screening models are not yet validated to definitively predict the de novo sensitizing potential of a novel protein. However, they would be extremely useful in the discovery and research phases of understanding the mechanisms of food allergy development, and may prove fruitful to provide information regarding potential allergenicity risk assessment of future products on a case by case basis. These data and findings were presented at a 2012 international symposium in Prague organized by the Protein Allergenicity Technical Committee of the International Life Sciences Institute's Health and Environmental Sciences Institute. PMID:24739743

  10. Screening of telomerase inhibitors.

    PubMed

    Kleideiter, Elke; Piotrowska, Kamilla; Klotz, Ulrich

    2007-01-01

    Shortening of telomeres prevents cells from uncontrolled proliferation. Progressive telomere shortening occurs at each cell division until a critical telomeric length is reached. Telomerase expression is switched off after embryonic differentiation in most normal cells, but it is expressed in a very high percentage of tumors of different origin. Thus, telomerase is regarded as the best tumor marker and a promising novel molecular target for cancer treatment. Therefore, different strategies to inhibit telomerase have been developed. However, systematic screening of telomerase inhibitors has not been performed to compare their therapeutic potential. We propose a suitable strategy for estimation of the therapeutic potential of telomerase inhibitors, which is based on a systematic screening of different inhibitors in the same cell system. From the long list of compounds discussed in the literature, we have selected four telomerase inhibitors of different structure and mode of action: BRACO19 (G-quadruplex-interactive compound), BIBR1532 (non-nucleosidic reverse transcriptase inhibitor), 2'-O-methyl RNA, and peptide nucleic acids (PNAs; hTR antisense oligonucleotides). To determine minimal effective concentrations for telomerase inhibition, telomerase activity was measured using the cell-free telomerase repeat amplification protocol (TRAP) assay. We also tested inhibitors in long-term cell-culture experiments by exposing A-549 cells to non-cytotoxic concentrations of inhibitors for a period of 99 days. Subsequently, telomerase activity of A-549 cells was investigated using the TRAP assay, and telomere length of samples was assessed by telomere restriction fragment (TRF) Southern blot analysis. PMID:18369824

  11. Allergic sensitization: screening methods

    PubMed Central

    2014-01-01

    Experimental in silico, in vitro, and rodent models for screening and predicting protein sensitizing potential are discussed, including whether there is evidence of new sensitizations and allergies since the introduction of genetically modified crops in 1996, the importance of linear versus conformational epitopes, and protein families that become allergens. Some common challenges for predicting protein sensitization are addressed: (a) exposure routes; (b) frequency and dose of exposure; (c) dose-response relationships; (d) role of digestion, food processing, and the food matrix; (e) role of infection; (f) role of the gut microbiota; (g) influence of the structure and physicochemical properties of the protein; and (h) the genetic background and physiology of consumers. The consensus view is that sensitization screening models are not yet validated to definitively predict the de novo sensitizing potential of a novel protein. However, they would be extremely useful in the discovery and research phases of understanding the mechanisms of food allergy development, and may prove fruitful to provide information regarding potential allergenicity risk assessment of future products on a case by case basis. These data and findings were presented at a 2012 international symposium in Prague organized by the Protein Allergenicity Technical Committee of the International Life Sciences Institute’s Health and Environmental Sciences Institute. PMID:24739743

  12. The controller, aviation medicine and air safety.

    PubMed

    Watkin, B L

    1983-03-01

    Aviation medicine has researched many important facts on pilots, but little on direct relationships between controllers, aviation medicine and air safety. The unsuspecting flying public accepts a 'blind faith' in aircraft and pilots, unaware that aircraft are controlled within 'suspect' ATC systems. The deceptive simplicity of controlling air traffic in apparently limitless skies belies the complexity of man-machine ATC systems operated in ever-crowded airspace, sometimes with antiquated equipment and indifferent communications. The indivisible operational controller/pilot team strives to meet similar ICAO medical standards and operate within the limitations of non-standardised recorded air traffic. Despite controllers' intensive stress at air disasters and 'almost' air disasters, air traffic must continually be controlled for air safety; but, countless human lives (and insurance dollars) saved are possibly camouflaged within the smoke screen of ATC. In New Zealand aviation, the Accident Compensation Corporation is statutorily responsible for air-safety, but accident investigators need controllers' expertise. Has a climate of complacency evolved towards air safety such that New Zealand's Erebus and other air disasters could have been avoided? Controllers are that crucial link in aviation with personal medical fitness vital to the air safety of the unsuspecting flying public. Controllers' dedicated aim for complete air safety in ATC shall benefit from greater understanding within aviation medicine and in-depth medical research. PMID:6847565

  13. Celiac disease during pregnancy: to screen or not to screen?

    PubMed

    Pope, Rachel; Sheiner, Eyal

    2009-01-01

    Permanent intolerance to gluten, known as celiac disease, affects both fertility and pregnancy outcomes when left untreated. Recent research on celiac disease and reproduction urge increased screening for celiac disease. While this may be beneficial for couples facing idiopathic infertility or those from particular risk groups, screening involves its own risks and expenses, and has not been consistently proven effective for the general population while pregnant. The present editorial discusses the potential advantages and disadvantages of screening during pregnancy and examines when screening may be helpful. PMID:18818937

  14. Anal Dysplasia Screening

    PubMed Central

    2007-01-01

    Executive Summary Objective This review considered the role of the anal Pap test as a screening test for anal dysplasia in patients at high risk of anal SCC. The screening process is now thought to be improved with the addition of testing for the human papillomavirus (HPV) in high-risk populations. High-resolution anoscopy (a method to view the rectal area, using an anoscope, a lighted instrument inserted into the rectum) rather than routine anoscopy-guided biopsy, is also now considered to be the diagnostic standard. Clinical Need: Target Population and Condition Anal cancer, like cervical cancer, is a member of a broader group of anogenital cancers known to be associated with sexually transmitted viral HPV infection. Human papillomavirus is extremely prevalent, particularly in young, sexually active populations. Sexual practices involving receptive anal intercourse lead to significantly elevated risk for anal dysplasia and cancer, particularly in those with immune dysfunctions. Anal cancer is rare. It occurs at a rate of about 1 to 2 per 100,000 in the general population. It is the least common of the lower gastrointestinal cancers, representing about 4% of them, in contrast to colorectal cancers, which remain the third most commonly diagnosed malignancy. Certain segments of the population, however, such as HIV-positive men and women, other chronic immune-suppressed patients (e.g., after a transplant), injection drug users, and women with genital dysplasia /cancer, have a high susceptibility to anal cancer. Those with the highest identified risk for anal cancer are HIV-positive homosexual and bisexual men, at a rate of 70 per 100,000 men. The risk for anal cancer is reported to be increasing dramatically in HIV-positive males and females, particularly since the introduction of highly active antiretroviral therapy in the mid-1990s. The introduction of effective viral therapy has been said to have transformed the AIDS epidemic in developed countries into a chronic

  15. Controversies in Lung Cancer Screening.

    PubMed

    Gill, Ritu R; Jaklitsch, Michael T; Jacobson, Francine L

    2016-02-01

    There remains an extensive debate over lung cancer screening, with lobbying for and against screening for very compelling reasons. The National Lung Screening Trial, International Early Lung Cancer Program, and other major screening studies favor screening with low-dose CT scans and have shown a reduction in lung cancer-specific mortality. The increasing incidence of lung cancer and the dismal survival rate for advanced disease despite improved multimodality therapy have sparked an interest in the implementation of national lung cancer screening. Concerns over imaging workflow, radiation dose, management of small nodules, overdiagnosis bias, lead-time and length-time bias, emerging new technologies, and cost-effectiveness continue to be debated. The authors address each of these issues as they relate to radiologic practice. PMID:26846531

  16. Critical congenital heart disease screening

    PubMed Central

    Chamsi-Pasha, Mohammed A.; Chamsi-Pasha, Hassan

    2016-01-01

    Critical congenital heart disease (CCHD) is a heart lesion for which neonates require early surgical intervention to survive. Without intervention, the rates of mortality and survival with significant disability are extremely high. Early diagnosis can potentially improve health outcomes in newborns with CCHD. Until recent years, no routine screening protocol existed. In the last few years, pulse oximetry screening for CCHD in newborns has been added to the list of recommended uniform screening panels and advocated by several health-care authorities. A positive screening test result warrants an echocardiogram to evaluate for CCHD. Newborn screens do not usually require parental consent. However, most of the states mandates in the United States include a statement allowing exemption from the screen on the basis of parental religious or personal beliefs. PMID:27390667

  17. Critical congenital heart disease screening.

    PubMed

    Chamsi-Pasha, Mohammed A; Chamsi-Pasha, Hassan

    2016-01-01

    Critical congenital heart disease (CCHD) is a heart lesion for which neonates require early surgical intervention to survive. Without intervention, the rates of mortality and survival with significant disability are extremely high. Early diagnosis can potentially improve health outcomes in newborns with CCHD. Until recent years, no routine screening protocol existed. In the last few years, pulse oximetry screening for CCHD in newborns has been added to the list of recommended uniform screening panels and advocated by several health-care authorities. A positive screening test result warrants an echocardiogram to evaluate for CCHD. Newborn screens do not usually require parental consent. However, most of the states mandates in the United States include a statement allowing exemption from the screen on the basis of parental religious or personal beliefs. PMID:27390667

  18. Antenatal haemoglobinopathy screening in Australia.

    PubMed

    Tan, Yi Ling; Kidson-Gerber, Giselle

    2016-04-01

    Haemoglobinopathy screening should be performed in women with microcytic indices, women from high risk ethnic populations and those with unexplained anaemia. Early testing of women and their partners expedites appropriate management prior to and during pregnancy. Haemoglobinopathy screening is a multistep process beginning with a full blood count, ferritin assay, screening tests for haemoglobinopathies (ie, haemoglobin electrophoresis, high performance liquid chromatography, capillary electrophoresis) and assessment of clinical risk. Iron deficiency may obscure the diagnosis of β-thalassaemia trait. If possible, haemoglobinopathy testing should be performed when the woman is iron-replete. Genetic testing can be offered on the basis of the combined risk of the couple; but turnaround times are lengthy at present, hence the emphasis on early pregnancy or pre-conception screening. Screening processes vary between states and local health districts; a uniform approach to screening and genetic testing with a national registry to record results would improve management of this growing problem. PMID:27031395

  19. Space engine safety system

    NASA Technical Reports Server (NTRS)

    Maul, William A.; Meyer, Claudia M.

    1991-01-01

    A rocket engine safety system is designed to initiate control procedures which will minimize damage to the engine and vehicle or test stand in the event of an engine failure. This report describes the features and the implementation issues associated with rocket engine safety systems. Specific concerns of safety systems applied to a space-based engine and long duration space missions are discussed. Examples of safety system features and architectures are given from recent safety monitoring investigations conducted for the Space Shuttle Main Engine and for future liquid rocket engines. Also, a general design and implementation process for rocket engine safety systems is presented.

  20. Space engine safety system

    NASA Technical Reports Server (NTRS)

    Maul, William A.; Meyer, Claudia M.

    1991-01-01

    A rocket engine safety system was designed to initiate control procedures to minimize damage to the engine or vehicle or test stand in the event of an engine failure. The features and the implementation issues associated with rocket engine safety systems are discussed, as well as the specific concerns of safety systems applied to a space-based engine and long duration space missions. Examples of safety system features and architectures are given, based on recent safety monitoring investigations conducted for the Space Shuttle Main Engine and for future liquid rocket engines. Also, the general design and implementation process for rocket engine safety systems is presented.

  1. Screening Adolescents and Young Women

    PubMed Central

    Boardman, Lori A.; Robison, Katina

    2013-01-01

    Synopsis Recent guidelines from multiple organizations, including the USPSTF, ACS/ASCCP/ASCP, ACOG and most recently the 2013 Update to the 2006 ASCCP Consensus Guidelines, all stress screening initiation no sooner than the age of 21 years and increased screening intervals for women aged 21 to 29 years. Primary prevention with HPV vaccination has the potential to significantly impact the development of high-grade cervical lesions, including cancer, and will likely affect screening guidelines in the future. PMID:23732030

  2. Ethics of dental health screening.

    PubMed

    Janakiram, Chandrashekar; Taha, Farheen

    2016-01-01

    Screening is the detection of disease at a point in its natural history when it is not yet symptomatic. In the natural history of dental caries, for example, the incipient lesions are at a reversible stage, which is a pre-symptomatic or an unrecognised symptomatic disease. Ideally, this is the stage during which screening should identify the risk of dental caries; however, presently, the so-called dental screening employed identifies the clinical cavitation of the tooth, which is very obvious to the individual. The individual already knows that he/she has dental caries and needs treatment, which the screening personnel (dental doctor) explains again during the screening procedure. Is it ethical to call such an event screening? The mushrooming of dental teaching hospitals has promoted regular screening of dental diseases among the communities and schoolchildren through their community dentistry-related activities. More often, it is a dental "check-up" that is carried out on the pretext of screening for dental diseases. Though the basic intention of this activity is to promote awareness of dental diseases and promote good health, there is also a hidden agenda to it. An artificial demand for dental care is created that is easily capitalised on by the dental teaching institutions to enhance its clinical activity. Dental screening is doing more harm than good as patients are made aware of the diseases for which they may not be able to afford treatment. This narrative review gives an account of the scientific evidence on screening for oral diseases, the current practices in screening and the ethical dilemmas of dental screening programmes. PMID:27474698

  3. Promoting Colorectal Cancer Screening Discussion

    PubMed Central

    Christy, Shannon M.; Perkins, Susan M.; Tong, Yan; Krier, Connie; Champion, Victoria L.; Skinner, Celette Sugg; Springston, Jeffrey K.; Imperiale, Thomas F.; Rawl, Susan M.

    2013-01-01

    Background Provider recommendation is a predictor of colorectal cancer (CRC) screening. Purpose To compare the effects of two clinic-based interventions on patient–provider discussions about CRC screening. Design Two-group RCT with data collected at baseline and 1 week post-intervention. Participants/setting African-American patients that were non-adherent to CRC screening recommendations (n=693) with a primary care visit between 2008 and 2010 in one of 11 urban primary care clinics. Intervention Participants received either a computer-delivered tailored CRC screening intervention or a nontailored informational brochure about CRC screening immediately prior to their primary care visit. Main outcome measures Between-group differences in odds of having had a CRC screening discussion about a colon test, with and without adjusting for demographic, clinic, health literacy, health belief, and social support variables, were examined as predictors of a CRC screening discussion using logistic regression. Intervention effects on CRC screening test order by PCPs were examined using logistic regression. Analyses were conducted in 2011 and 2012. Results Compared to the brochure group, a greater proportions of those in the computer-delivered tailored intervention group reported having had a discussion with their provider about CRC screening (63% vs 48%, OR=1.81, p<0.001). Predictors of a discussion about CRC screening included computer group participation, younger age, reason for visit, being unmarried, colonoscopy self-efficacy, and family member/friend recommendation (all p-values <0.05). Conclusions The computer-delivered tailored intervention was more effective than a nontailored brochure at stimulating patient–provider discussions about CRC screening. Those who received the computer-delivered intervention also were more likely to have a CRC screening test (fecal occult blood test or colonoscopy) ordered by their PCP. Trial registration This study is registered at www

  4. Evolution of Biologics Screening Technologies

    PubMed Central

    Cariuk, Peter; Gardener, Matthew J.; Vaughan, Tristan J.

    2013-01-01

    Screening for biologics, in particular antibody drugs, has evolved significantly over the last 20 years. Initially, the screening processes and technologies from many years experience with small molecules were adopted and modified to suit the needs of biologics discovery. Since then, antibody drug discovery has matured significantly and is today investing earlier in new technologies that commercial suppliers are now developing specifically to meet the growing needs of large molecule screening. Here, we review the evolution of screening and automation technologies employed in antibody discovery and highlight the benefits that these changes have brought. PMID:24276173

  5. A noise control package for vibrating screens1),2)

    PubMed Central

    Lowe, M. Jenae; Yantek, David S.; Yang, Junyi; Schuster, Kevin C.; Mechling, Jessie J.

    2015-01-01

    Hearing loss was the second-most common illness reported to the Mine Safety and Health Administration (MSHA) in 2009. Furthermore, between 2000 and 2010, 30% of all noise-related injury complaints reported to MSHA were for coal preparation plant employees. Previous National Institute for Occupational Safety and Health (NIOSH) studies have shown that vibrating screens are key noise sources to address in order to reduce coal preparation plant noise. In response, NIOSH researchers have developed a suite of noise controls for vibrating screens consisting of constrained layer damping (CLD) treatments, a tuned mechanism suspension, an acoustic enclosure, and spring inserts. Laboratory testing demonstrates that this noise control suite reduces the A-weighted sound power level of the vibrating screen by 6 dB. To provide a comparison to laboratory results and prove durability, field testing of two noise controls was performed on a vibrating screen in a working coal preparation plant. The spring inserts and CLD treatments were selected due to their ease of installation and practicability. Field testing of these controls yielded reductions that were comparable to laboratory results. PMID:26257468

  6. Screening for lung cancer.

    PubMed Central

    Carter, D.

    1981-01-01

    The survival from bronchogenic carcinoma is highly dependent upon stage at the time of treatment. This is particularly true for squamous cell carcinoma, adenocarcinoma, and large cell carcinoma, but holds true for small cell carcinoma as well. The problem presented to the medical profession has been to find a practical means of detecting lung cancer while it is still at an early stage. Three studies in progress have indicated that a larger proportion of the patients may be found to have early stage lung cancer when screened with a combination of chest X-rays and sputum cytology. However, the detection of these early stage cases has not yet been translated into an improvement in the overall mortality rate from lung cancer. PMID:6278787

  7. Environmental Test Screening Procedure

    NASA Technical Reports Server (NTRS)

    Zeidler, Janet

    2000-01-01

    This procedure describes the methods to be used for environmental stress screening (ESS) of the Lightning Mapper Sensor (LMS) lens assembly. Unless otherwise specified, the procedures shall be completed in the order listed, prior to performance of the Acceptance Test Procedure (ATP). The first unit, S/N 001, will be subjected to the Qualification Vibration Levels, while the remainder will be tested at the Operational Level. Prior to ESS, all units will undergo Pre-ESS Functional Testing that includes measuring the on-axis and plus or minus 0.95 full field Modulation Transfer Function and Back Focal Length. Next, all units will undergo ESS testing, and then Acceptance testing per PR 460.

  8. Lung cancer screening

    PubMed Central

    Pastorino, U

    2010-01-01

    Lung cancer is the primary cause of cancer mortality in developed countries. First diagnosis only when disease has already reached the metastatic phase is the main reason for failure in treatment. To this regard, although low-dose spiral computed tomography (CT) has proven to be effective in the early detection of lung cancer (providing both higher resectability and higher long-term survival rates), the capacity of annual CT screening to reduce lung cancer mortality in heavy smokers has yet to be demonstrated. Numerous ongoing large-scale randomised trials are under way in high-risk individuals with different study designs. The initial results should be available within the next 2 years. PMID:20424610

  9. Comments on Gaugino Screening

    SciTech Connect

    Cohen, Timothy; Hook, Anson; Wecht, Brian

    2012-02-15

    Gauge mediated models of supersymmetry breaking often exhibit 'gaugino screening,' where to leading order in F, gaugino masses are unaffected by higher dimensional Kahler potential interactions between the supersymmetry breaking spurion and the messengers. We provide a derivation of this phenomenon which utilizes the gaugino counterterm originally proposed in the context of anomaly mediation by Dine and Seiberg. We argue that this counterterm is present when there are non-zero messenger F-terms, and can cancel the leading order Feynman diagram contribution to the gaugino mass. We provide a nontrivial check of the regulator independence of our results by performing the computation using both dimensional reduction and Pauli-Villars. This analysis reconciles an apparent contradiction between diagrammatics and analytic continuation into superspace.

  10. Photorefractor ocular screening system

    NASA Technical Reports Server (NTRS)

    Richardson, John R. (Inventor); Kerr, Joseph H. (Inventor)

    1987-01-01

    A method and apparatus for detecting human eye defects, particularly detection of refractive error is presented. Eye reflex is recorded on color film when the eyes are exposed to a flash of light. The photographs are compared with predetermined standards to detect eye defects. The base structure of the ocular screening system is a folding interconnect structure, comprising hinged sections. Attached to one end of the structure is a head positioning station which comprises vertical support, a head positioning bracket having one end attached to the top of the support, and two head positioning lamps to verify precise head positioning. At the opposite end of the interconnect structure is a camera station with camera, electronic flash unit, and blinking fixation lamp, for photographing the eyes of persons being evaluated.

  11. Vocational Education Safety Instruction Manual.

    ERIC Educational Resources Information Center

    Cropley, Russell, Ed.; Doherty, Susan Sloan, Ed.

    This manual describes four program areas in vocational education safety instruction: (1) introduction to a safety program; (2) resources to ensure laboratory safety; (3) safety program implementation; and (4) safety rules and safety tests. The safety rules and tests included in section four are for the most common tools and machines used in…

  12. Early Childhood Developmental Screenings: Predictors of Screening Referral Completion

    ERIC Educational Resources Information Center

    Jennings, Danielle J.

    2012-01-01

    Developmental screening programs identify young children with delayed skill growth or challenging behaviors and refer them to community agencies for evaluation or other services. This research studied the predictive impact of developmental screening results and child and family characteristics on the completion of these referrals for evaluation. A…

  13. Medicine safety and children

    MedlinePlus

    ... this page: //medlineplus.gov/ency/patientinstructions/000619.htm Medicine safety and children To use the sharing features ... especially careful if you have toddlers around. Keep Medicines out of Reach and Sight Safety tips: DO ...

  14. Water safety and drowning

    MedlinePlus

    ... among people of all ages. Learning and practicing water safety is important to prevent drowning accidents. ... Water safety tips for all ages include: Learn CPR Never swim alone Never dive into water unless ...

  15. Safety organizations and experts

    NASA Technical Reports Server (NTRS)

    Mandel, G.; Rubinstein, R. I.; Pinto, J. J.; Meschkow, S. Z.

    1977-01-01

    Handbook lists organizations and experts in specific, well defined areas of safety technology. Special emphasis is given to relevant safety information sources on aircraft fire hazards and aircraft interior flammability.

  16. Motor Vehicle Safety

    MedlinePlus

    ... these crashes is one part of motor vehicle safety. Here are some things you can do to ... speed or drive aggressively Don't drive impaired Safety also involves being aware of others. Share the ...

  17. Farm Health and Safety

    MedlinePlus

    ... the United States. Farms have many health and safety hazards, including Chemicals and pesticides Machinery, tools and ... inspection and maintenance can help prevent accidents. Using safety gloves, goggles and other protective equipment can also ...

  18. Safety in Science Laboratories.

    ERIC Educational Resources Information Center

    Education in Science, 1978

    1978-01-01

    Presents 12 amendments to the second edition of Safety in Science Laboratories. Covers topics such as regular inspection of equipment, wearing safety glasses, dating stock chemicals, and safe use of chemicals. (MA)

  19. Security vs. Safety.

    ERIC Educational Resources Information Center

    Sturgeon, Julie

    1999-01-01

    Provides administrative advice on how some safety experts have made college campuses safer and friendlier without breaking the budget. Tips on security and advice on safety management that encompasses the whole environment are highlighted. (GR)

  20. Facility safety study

    NASA Technical Reports Server (NTRS)

    1979-01-01

    The safety of NASA's in house microelectronics facility is addressed. Industrial health standards, facility emission control requirements, operation and safety checklists, and the disposal of epitaxial vent gas are considered.

  1. Spacecraft Fire Safety

    NASA Technical Reports Server (NTRS)

    Margle, Janice M. (Editor)

    1987-01-01

    Fire detection, fire standards and testing, fire extinguishment, inerting and atmospheres, fire-related medical science, aircraft fire safety, Space Station safety concerns, microgravity combustion, spacecraft material flammability testing, and metal combustion are among the topics considered.

  2. Display screen and method of manufacture therefor

    NASA Technical Reports Server (NTRS)

    Dubin, Matthew B. (Inventor); Larson, Brent D. (Inventor)

    2002-01-01

    A screen assembly that combines an angle re-distributing prescreen with a conventional diffusion screen. The prescreen minimizes or eliminates the sensitivity of the screen assembly to projector location. The diffusion screen provides other desirable screen characteristics. Compatible screen structures, along with methods for fabricating high resolution prescreens and methods and devices for maintaining the desired relationship between the prescreen and the diffusion screen are contemplated.

  3. Electrical safety guidelines

    SciTech Connect

    Not Available

    1993-09-01

    The Electrical Safety Guidelines prescribes the DOE safety standards for DOE field offices or facilities involved in the use of electrical energy. It has been prepared to provide a uniform set of electrical safety standards and guidance for DOE installations in order to affect a reduction or elimination of risks associated with the use of electrical energy. The objectives of these guidelines are to enhance electrical safety awareness and mitigate electrical hazards to employees, the public, and the environment.

  4. Safety analysts training

    SciTech Connect

    Bolton, P.

    2000-10-01

    The purpose of this task was to support ESH-3 in providing Airborne Release Fraction and Respirable Fraction training to safety analysts at LANL who perform accident analysis, hazard analysis, safety analysis, and/or risk assessments at nuclear facilities. The task included preparation of materials for and the conduct of two 3-day training courses covering the following topics: safety analysis process; calculation model; aerosol physic concepts for safety analysis; and overview of empirically derived airborne release fractions and respirable fractions.

  5. DOE handbook electrical safety

    SciTech Connect

    1998-01-01

    Electrical Safety Handbook presents the Department of Energy (DOE) safety standards for DOE field offices or facilities involved in the use of electrical energy. It has been prepared to provide a uniform set of electrical safety guidance and information for DOE installations to effect a reduction or elimination of risks associated with the use of electrical energy. The objectives of this handbook are to enhance electrical safety awareness and mitigate electrical hazards to employees, the public, and the environment.

  6. Radiation Safety Compliance.

    PubMed

    Koth, Jana; Smith, Marcia Hess

    2016-05-01

    This article discusses radiation safety programs, including the members of the radiation safety team, their roles, and the challenges they face, with a focus on the radiation safety officer's duties. Agencies that regulate radiation safety also are described. The importance of minimizing patient dose, ensuring that dosimetry badges are worn correctly, and using therapeutic radioactive materials safely are addressed. Finally, radiologic technologists' role in using radiation safely is discussed, and the principles of time, distance, and shielding are reviewed. PMID:27146175

  7. Generic safety documentation model

    SciTech Connect

    Mahn, J.A.

    1994-04-01

    This document is intended to be a resource for preparers of safety documentation for Sandia National Laboratories, New Mexico facilities. It provides standardized discussions of some topics that are generic to most, if not all, Sandia/NM facilities safety documents. The material provides a ``core`` upon which to develop facility-specific safety documentation. The use of the information in this document will reduce the cost of safety document preparation and improve consistency of information.

  8. Aviation Safety Issues Database

    NASA Technical Reports Server (NTRS)

    Morello, Samuel A.; Ricks, Wendell R.

    2009-01-01

    The aviation safety issues database was instrumental in the refinement and substantiation of the National Aviation Safety Strategic Plan (NASSP). The issues database is a comprehensive set of issues from an extremely broad base of aviation functions, personnel, and vehicle categories, both nationally and internationally. Several aviation safety stakeholders such as the Commercial Aviation Safety Team (CAST) have already used the database. This broader interest was the genesis to making the database publically accessible and writing this report.

  9. HSE's safety assessment principles for criticality safety.

    PubMed

    Simister, D N; Finnerty, M D; Warburton, S J; Thomas, E A; Macphail, M R

    2008-06-01

    The Health and Safety Executive (HSE) published its revised Safety Assessment Principles for Nuclear Facilities (SAPs) in December 2006. The SAPs are primarily intended for use by HSE's inspectors when judging the adequacy of safety cases for nuclear facilities. The revised SAPs relate to all aspects of safety in nuclear facilities including the technical discipline of criticality safety. The purpose of this paper is to set out for the benefit of a wider audience some of the thinking behind the final published words and to provide an insight into the development of UK regulatory guidance. The paper notes that it is HSE's intention that the Safety Assessment Principles should be viewed as a reflection of good practice in the context of interpreting primary legislation such as the requirements under site licence conditions for arrangements for producing an adequate safety case and for producing a suitable and sufficient risk assessment under the Ionising Radiations Regulations 1999 (SI1999/3232 www.opsi.gov.uk/si/si1999/uksi_19993232_en.pdf). PMID:18495990

  10. Development of a Comprehensive Database System for Safety Analyst.

    PubMed

    Paz, Alexander; Veeramisti, Naveen; Khanal, Indira; Baker, Justin; de la Fuente-Mella, Hanns

    2015-01-01

    This study addressed barriers associated with the use of Safety Analyst, a state-of-the-art tool that has been developed to assist during the entire Traffic Safety Management process but that is not widely used due to a number of challenges as described in this paper. As part of this study, a comprehensive database system and tools to provide data to multiple traffic safety applications, with a focus on Safety Analyst, were developed. A number of data management tools were developed to extract, collect, transform, integrate, and load the data. The system includes consistency-checking capabilities to ensure the adequate insertion and update of data into the database. This system focused on data from roadways, ramps, intersections, and traffic characteristics for Safety Analyst. To test the proposed system and tools, data from Clark County, which is the largest county in Nevada and includes the cities of Las Vegas, Henderson, Boulder City, and North Las Vegas, was used. The database and Safety Analyst together help identify the sites with the potential for safety improvements. Specifically, this study examined the results from two case studies. The first case study, which identified sites having a potential for safety improvements with respect to fatal and all injury crashes, included all roadway elements and used default and calibrated Safety Performance Functions (SPFs). The second case study identified sites having a potential for safety improvements with respect to fatal and all injury crashes, specifically regarding intersections; it used default and calibrated SPFs as well. Conclusions were developed for the calibration of safety performance functions and the classification of site subtypes. Guidelines were provided about the selection of a particular network screening type or performance measure for network screening. PMID:26167531

  11. Development of a Comprehensive Database System for Safety Analyst

    PubMed Central

    Paz, Alexander; Veeramisti, Naveen; Khanal, Indira; Baker, Justin; de la Fuente-Mella, Hanns

    2015-01-01

    This study addressed barriers associated with the use of Safety Analyst, a state-of-the-art tool that has been developed to assist during the entire Traffic Safety Management process but that is not widely used due to a number of challenges as described in this paper. As part of this study, a comprehensive database system and tools to provide data to multiple traffic safety applications, with a focus on Safety Analyst, were developed. A number of data management tools were developed to extract, collect, transform, integrate, and load the data. The system includes consistency-checking capabilities to ensure the adequate insertion and update of data into the database. This system focused on data from roadways, ramps, intersections, and traffic characteristics for Safety Analyst. To test the proposed system and tools, data from Clark County, which is the largest county in Nevada and includes the cities of Las Vegas, Henderson, Boulder City, and North Las Vegas, was used. The database and Safety Analyst together help identify the sites with the potential for safety improvements. Specifically, this study examined the results from two case studies. The first case study, which identified sites having a potential for safety improvements with respect to fatal and all injury crashes, included all roadway elements and used default and calibrated Safety Performance Functions (SPFs). The second case study identified sites having a potential for safety improvements with respect to fatal and all injury crashes, specifically regarding intersections; it used default and calibrated SPFs as well. Conclusions were developed for the calibration of safety performance functions and the classification of site subtypes. Guidelines were provided about the selection of a particular network screening type or performance measure for network screening. PMID:26167531

  12. Virtual Safety Training.

    ERIC Educational Resources Information Center

    Fuller, Scott; Davis, Jason

    2003-01-01

    The Multimedia Tool Box Talk is a web-based quick reference safety guide and training tool for construction personnel. An intended outcome of this effort was to provide an efficient and effective way to locate and interpret crucial safety information while at the job site. The tool includes information from the Occupational Safety and Health…

  13. School Safety Audit Protocol.

    ERIC Educational Resources Information Center

    DeMary, Jo Lynne; Owens, Marsha; Ramnarain, A. K. Vijay

    The 1997 Virginia General Assembly passed legislation directing school boards to require all schools to conduct safety audits. This audit is designed to assess the safety conditions in each public school to: (1) identify and, if necessary, develop solutions for physical safety concerns, including building security issues; and (2) identify and…

  14. Safety in the Preschool.

    ERIC Educational Resources Information Center

    Settles, Mimi

    Guidelines for safety in the cooperative preschool are outlined, emphasizing control of the physical environment to insure maximum freedom for the children compatible with maximum safety. Building standards are set for stairways, rooms, lavatories, parking lots, harmful supplies, and wading pools. Orientation for safety is discussed in regard to…

  15. Revitalizing Nuclear Safety Research.

    ERIC Educational Resources Information Center

    National Academy of Sciences - National Research Council, Washington, DC.

    This report covers the general issues involved in nuclear safety research and points out the areas needing detailed consideration. Topics included are: (1) "Principles of Nuclear Safety Research" (examining who should fund, who should conduct, and who should set the agenda for nuclear safety research); (2) "Elements of a Future Agenda for Nuclear…

  16. School Bus Safety.

    ERIC Educational Resources Information Center

    Stroup, Karen Bruner; And Others

    1991-01-01

    Equipment to allow safe transportation of disabled children is reviewed. Such equipment includes infant car seats, child safety seats, safety vests, and accommodations for children in casts and/or braces. Five principles for evaluation and selection of safe seating options are given as are safety rules and information on standards and resources.…

  17. SNTP environmental, safety, and health

    NASA Technical Reports Server (NTRS)

    Harmon, Charles D.

    1993-01-01

    Viewgraphs on space nuclear thermal propulsion (SNTP) environmental, safety, and health are presented. Topics covered include: program safety policy; program safety policies; and DEIS public hearing comments.

  18. Smart Screening System (S3) In Taconite Processing

    SciTech Connect

    Daryoush Allaei; Asim Syed Mohammed; David Tarnowski

    2004-09-01

    The conventional vibrating machines used in processing plants have had undesirable high noise and vibration levels. They also have had unsatisfactorily low screening efficiency, high energy consumption, high maintenance cost, low productivity, and poor worker safety. These conventional vibrating machines have been used in most every processing plant. Most of the current material separation technology uses heavy and inefficient electric motors with an unbalance rotating mass to generate the shaking. In addition to being excessively noisy, inefficient, and high-maintenance, these vibrating machines are often the bottleneck in the entire process. Furthermore, these motors, along with the vibrating machines and supporting structure, shake other machines and structures in the vicinity. The latter increases maintenance costs while reducing worker health and safety. The conventional vibrating fine screens at taconite processing plants have had the same problems as those listed above. This has resulted in lower screening efficiency, higher energy and maintenance cost, and lower productivity and workers safety concerns. The focus of this work is on the design of a high performance screening machine suitable for taconite processing plants. SmartScreens{trademark} technology uses miniaturized motors, based on smart materials, to generate the shaking. The underlying technologies are Energy Flow Control{trademark} and Vibration Control by Confinement{trademark}. These concepts are used to direct energy flow and confine energy efficiently and effectively to the screen function. The SmartScreens{trademark} technology addresses problems related to noise and vibration, screening efficiency, productivity, and maintenance cost and worker safety. Successful development of SmartScreens{trademark} technology will bring drastic changes to the screening and physical separation industry. The final designs for key components of the SmartScreens{trademark} have been developed. The key

  19. Screening sealed bottles for liquid explosives

    NASA Astrophysics Data System (ADS)

    Kumar, Sankaran; McMichael, W. Casey; Kim, Y.-W.; Sheldon, Alan G.; Magnuson, Erik E.; Ficke, L.; Chhoa, T. K.; Moeller, C. R.; Barrall, Geoffrey A.; Burnett, Lowell J.; Czipott, Peter V.; Pence, J. S.; Skvoretz, David C.

    1997-01-01

    A particularly disturbing development affecting transportation safety and security is the increasing use of terrorist devices which avoid detection by conventional means through the use of liquid explosives and flammables. The hazardous materials are generally hidden in wine or liquor bottles that cannot be opened routinely for inspection. This problem was highlighted by the liquid explosives threat which disrupted air traffic between the US an the Far East for an extended period in 1995. Quantum Magnetics has developed a Liquid Explosives Screening systems capable of scanning unopened bottles for liquid explosives. The system can be operated to detect specific explosives directly or to verify the labeled or bar-coded contents of the container. In this system, magnetic resonance (MR) is used to interrogate the liquid. MR produces an extremely rich data set and many characteristics of the MR response can be determined simultaneously. As a result, multiple MR signatures can be defined for any given set of liquids, and the signature complexity then selected according to the level of threat. The Quantum Magnetics Liquid Explosives Screening System is currently operational. Following extensive laboratory testing, a field trial of the system was carried out at the Los Angeles International Airport.

  20. Impedance in School Screening Programs.

    ERIC Educational Resources Information Center

    Robarts, John T.

    1985-01-01

    This paper examines the controversy over use of impedance screening in public schools to identify students with hearing problems, including otitis media, a common ear condition in infants and young children. It cites research that questions the value of pure tone screening as a single test and raises critics' objections to the use of impedance,…

  1. Screening College Students for Hypercholesterolemia.

    ERIC Educational Resources Information Center

    Faigel, Harris C.

    1992-01-01

    Describes one college's mandatory mass cholesterol screening for new students. Each year, over 30 beginning students with unknown hypercholesterolemia were detected. The program suggests that mass screening efficiently and economically identifies students who would benefit from cholesterol reduction, a modifiable risk in coronary artery disease.…

  2. Vision Screening For Head Starters.

    ERIC Educational Resources Information Center

    Foley, Celia

    To determine which children in the Head Start program may have vision problems, Head Start teachers and staff do vision "screening." This booklet demonstrates how to do the screening using the Snellen "E Chart." Trouble signs that the test administrator should be aware of are listed, and vision scores are explained simply. Amblyopia is defined,…

  3. Optimal screening for genetic diseases.

    PubMed

    Nævdal, Eric

    2014-12-01

    Screening for genetic diseases is performed in many regions and/or ethnic groups where there is a high prevalence of possibly malign genes. The propagation of such genes can be considered a dynamic externality. Given that many of these diseases are untreatable and give rise to truly tragic outcomes, they are a source of societal concern, and the screening process should perhaps be regulated. This paper incorporates a standard model of genetic propagation into an economic model of dynamic management to derive cost benefit rules for optimal screening. The highly non-linear nature of genetic dynamics gives rise to perhaps surprising results that include discontinuous controls and threshold effects. One insight is that any screening program that is in place for any amount of time should screen all individuals in a target population. The incorporation of genetic models may prove to be useful to several emerging fields in economics such as genoeconomics, neuroeconomics and paleoeconomics. PMID:25203815

  4. Health economic analysis of screening

    PubMed Central

    Krauth, Christian

    2010-01-01

    In this article health economic implications of screening are analysed. First, requirements screening programmes should fulfil are derived, and methodical standards of health economic evaluation are outlined. Using the example of newborn hearing screening, it is then examined if empirical studies meet the methodical requirements of health economic evaluation. Some deficits are realised: Health economic studies of newborn hearing screening are not randomised, most studies are even not controlled. Therefore, most studies do not present incremental, but only average cost-effectiveness ratios (i.e. cost per case identified). Furthermore, evidence on long-term outcomes of screening and early interventions is insufficient. In conclusion, there is a need for controlled trials to examine differences in identified cases, but particularly to examine long-term effects. PMID:22073088

  5. Down syndrome screening in twins.

    PubMed

    Bush, Melissa C; Malone, Fergal D

    2005-06-01

    Available methods for screening for Down syndrome (DS) in twin gestations include maternal age, first-trimester nuchal translucency, first-trimester combined screening, second-trimester genetic sonography, second-trimester quad screening, and combinations of tests across different gestational ages. Biochemical screening is generally associated with detection rates at least 15% less than in singleton pregnancies. Nuchal translucency measurement may help close that gap, but the best available data (based on modeling) show approximately 75% to 85% detection rates for DS, with a 5% false-positive rate. Patients accepting screening should be aware of all options should a diagnosis of fetal aneuploidy be confirmed, including pregnancy continuation, termination of the entire pregnancy, and selective termination of an aneuploid fetus. PMID:15922788

  6. Biomarkers in Colorectal Cancer Screening.

    PubMed

    Nguyen, Minhhuyen T; Weinberg, David S

    2016-08-01

    Colorectal cancer (CRC) is the third most common cause of cancer death in men and women in the United States. The main goals of screening are to prevent carcinogenesis (via adenoma detection and removal) and detect cancer at an early, curable stage. CRC mortality is steadily dropping in the United States, partly because of greater screening utilization. However, nearly 1 in 3 average-risk people are not up to date with standard CRC screening recommendations. This review surveys a wide range of CRC biomarkers in various stages of development, which may offer attractive risk stratification tools; a few have reached the commercial stage. If widely accepted, these tools may contribute to shift CRC screening practices away from 1-step colonoscopy to a 2-step risk stratification process of predictive biomarker measurements followed by colonoscopy for lower-risk patients with a positive result. Such strategies could potentially increase the rate of CRC screening. PMID:27496118

  7. Safety and IVHM

    NASA Technical Reports Server (NTRS)

    Goebel, Kai

    2012-01-01

    When we address safety in a book on the business case for IVHM, the question arises whether safety isn t inherently in conflict with the need of operators to run their systems as efficiently (and as cost effectively) as possible. The answer may be that the system needs to be just as safe as needed, but not significantly more. That begs the next question: How safe is safe enough? Several regulatory bodies provide guidelines for operational safety, but irrespective of that, operators do not want their systems to be known as lacking safety. We illuminate the role of safety within the context of IVHM.

  8. Safety after cardiac catheterization.

    PubMed

    Huber, Charlotte

    2009-08-01

    The Pennsylvania Patient Safety Authority's reporting system is a confidential, statewide Internet reporting system to which all Pennsylvania hospitals, outpatient-surgery facilities, and birthing centers, as well as some abortion facilities, must file information on medical errors. Safety Monitor is a column from the authority that informs nurses on issues that can affect patient safety and presents strategies they can easily integrate into practice. For more information on the authority, visit www.patientsafetyauthority.org. For the original article discussed in this column or for other articles on patient safety, click on "Patient Safety Advisories" and then "Advisory Library" in the left-hand navigation menu. PMID:19641415

  9. NASA Safety Manual. Volume 3: System Safety

    NASA Technical Reports Server (NTRS)

    1970-01-01

    This Volume 3 of the NASA Safety Manual sets forth the basic elements and techniques for managing a system safety program and the technical methods recommended for use in developing a risk evaluation program that is oriented to the identification of hazards in aerospace hardware systems and the development of residual risk management information for the program manager that is based on the hazards identified. The methods and techniques described in this volume are in consonance with the requirements set forth in NHB 1700.1 (VI), Chapter 3. This volume and future volumes of the NASA Safety Manual shall not be rewritten, reprinted, or reproduced in any manner. Installation implementing procedures, if necessary, shall be inserted as page supplements in accordance with the provisions of Appendix A. No portion of this volume or future volumes of the NASA Safety Manual shall be invoked in contracts.

  10. Safety Tips: Safety Is No Laughing Matter.

    ERIC Educational Resources Information Center

    Hill, Patricia S.; Greco, Thomas G.

    1995-01-01

    Presents the script of a skit designed to engage beginning students in a contest to identify and list the most safety violations they observe during the skit. Includes a list of 37 safe laboratory practices. (MKR)

  11. Screening for Generalized Anxiety Disorder (GAD)

    MedlinePlus

    ... Screening for Posttraumatic Stress Disorder (PTSD) Screening for Social Anxiety Disorder Screening for Specific Phobias Screening for an Anxiety Disorder: Children Screening for an Anxiety Disorder: Family Member Self-Help Strategies: Webinars to Calm Anxious Minds "Triumph" E-News ...

  12. Screening for Obsessive-Compulsive Disorder (OCD)

    MedlinePlus

    ... Screening for Posttraumatic Stress Disorder (PTSD) Screening for Social Anxiety Disorder Screening for Specific Phobias Screening for an Anxiety Disorder: Children Screening for an Anxiety Disorder: Family Member Self-Help Strategies: Webinars to Calm Anxious Minds "Triumph" E-News ...

  13. NASA Software Safety Standard

    NASA Technical Reports Server (NTRS)

    Rosenberg, Linda

    1997-01-01

    If software is a critical element in a safety critical system, it is imperative to implement a systematic approach to software safety as an integral part of the overall system safety programs. The NASA-STD-8719.13A, "NASA Software Safety Standard", describes the activities necessary to ensure that safety is designed into software that is acquired or developed by NASA, and that safety is maintained throughout the software life cycle. A PDF version, is available on the WWW from Lewis. A Guidebook that will assist in the implementation of the requirements in the Safety Standard is under development at the Lewis Research Center (LeRC). After completion, it will also be available on the WWW from Lewis.

  14. Maintenance of safety behaviors via response-produced stimuli.

    PubMed

    Angelakis, Ioannis; Austin, Jennifer L

    2015-11-01

    Animal studies suggest that safety behaviors may be maintained by internally or externally produced safety signals, which function as positive reinforcers. We designed two experiments to test this phenomenon with humans. Participants played a computerized game in which they could earn or lose treasures by clicking on a map. In baseline, losses could be postponed by pressing a pedal that also produced a blue bar at the bottom of the screen. During test conditions, no losses were programmed, and pedal presses turned the bar from yellow to blue (Test 1) or blue to yellow (Test 2). In Experiment 2, new participants were exposed to the same conditions but were given information about the safety of the test environment. In both experiments, participants engaged in high rates of pedal pressing when presses were followed by blue bars, suggesting the bar functioned as a safety signal. We discuss how these findings may relate to safety behaviors commonly observed in certain mental health disorders. PMID:26463997

  15. Highway Safety Program Manual: Volume 14: Pedestrian Safety.

    ERIC Educational Resources Information Center

    National Highway Traffic Safety Administration (DOT), Washington, DC.

    Volume 14 of the 19-volume Highway Safety Program Manual (which provides guidance to State and local governments on preferred highway safety practices) concentrates on pedestrian safety. The purpose and objectives of a pedestrian safety program are outlined. Federal authority in the area of pedestrian safety and policies regarding a safety program…

  16. The screening Horndeski cosmologies

    NASA Astrophysics Data System (ADS)

    Starobinsky, Alexei A.; Sushkov, Sergey V.; Volkov, Mikhail S.

    2016-06-01

    We present a systematic analysis of homogeneous and isotropic cosmologies in a particular Horndeski model with Galileon shift symmetry, containing also a Λ-term and a matter. The model, sometimes called Fab Five, admits a rich spectrum of solutions. Some of them describe the standard late time cosmological dynamic dominated by the Λ-term and matter, while at the early times the universe expands with a constant Hubble rate determined by the value of the scalar kinetic coupling. For other solutions the Λ-term and matter are screened at all times but there are nevertheless the early and late accelerating phases. The model also admits bounces, as well as peculiar solutions describing ``the emergence of time''. Most of these solutions contain ghosts in the scalar and tensor sectors. However, a careful analysis reveals three different branches of ghost-free solutions, all showing a late time acceleration phase. We analyse the dynamical stability of these solutions and find that all of them are stable in the future, since all their perturbations stay bounded at late times. However, they all turn out to be unstable in the past, as their perturbations grow violently when one approaches the initial spacetime singularity. We therefore conclude that the model has no viable solutions describing the whole of the cosmological history, although it may describe the current acceleration phase. We also check that the flat space solution is ghost-free in the model, but it may acquire ghost in more general versions of the Horndeski theory.

  17. Inertial Screening in Sedimentation

    NASA Technical Reports Server (NTRS)

    Segre, P. N.; Curreri, Peter A. (Technical Monitor)

    2001-01-01

    Using particle image velocimetry we have measured the sedimentation dynamics of non-Brownian spheres over a wide range of Reynolds numbers (Re) between 0.001 and 2.5. Particle velocity fluctuations about the mean settling velocity show large-scale correlations whose spatial extent and magnitude Delta V/V are independent of Re up to a critical value Re less than Re(sub c). For Re greater than Re(sub c) the fluctuations substantially diminish with increasing Reynolds number due to inertial screening of the long-range hydrodynamic interactions (HI). The onset of inertial affects is found to occur when the Oseen length l(sub o)=v/V becomes of order the correlation length. In the inertial regime, the velocity fluctuations follow -(Delta V/V)(sup 2) approaching ln(Re), in agreement with an integration of the (l/r) HI over a narrow region extending up to the Oseen length l(sub o). A simple "blob" model connects the measured correlation lengths to the magnitudes of the velocity fluctuations.

  18. The evolution of screening.

    PubMed

    Gray, J A

    2001-01-01

    Botany is usually considered to be the gentlest of sciences with botanists being regarded as people who study relatively safe specimens, compared with, for example, anthropologists or microbiologists. However, botanists have their moments, particularly when collecting new species. The great botanists of the eighteenth and nineteenth centuries risked their lives in collecting and bringing back species, which we now take for granted, and Robert Brown was one of these adventurers, a young Scot who accompanied Sir Joseph Banks to New Holland. It was not, however, for his adventurous lifestyle that Brown is remembered but for his startling observation of the movements of pollen grains on a microscope slide. He noted that the pollen grains were in perpetual agitated motion, without purpose or direction but full of energy. This motion, called Brownian motion, arises from the movement of molecules, and Brownian motion is the term that has been applied to much of healthcare, including many screening programmes, which have in the past been marked more by the amount of energy and activity than by a clear sense of direction or positive achievement. PMID:11417069

  19. Congenital Cataract Screening.

    PubMed

    Rajavi, Zhale; Sabbaghi, Hamideh

    2016-01-01

    Congenital cataract is a leading cause of visual deprivation which can damage the developing visual system of a child; therefore early diagnosis, management and long-term follow-up are essential. It is recommended that all neonates be screened by red reflex examination at birth and suspected cases be referred to ophthalmic centers. Early surgery (<6 weeks of age, based on general neonatal health) is important for achieving the best visual outcome particularly in unilateral cases. In bilateral cases, surgery is highly recommended before appearance of strabismus or nystagmus (<10 weeks of age) with no longer than a one-week interval between the fellow eyes. Parents should be informed that surgery is a starting point and not the endpoint of treatment. Appropriate postoperative management including immediate optical correction in the form of aphakic glasses or contact lenses, or intraocular lens (IOL) implantation at the appropriate age (>1 year) is highly recommended. After surgery, amblyopia treatment and periodic follow-up examinations should be started as soon as possible to achieve a satisfactory visual outcome. Practitioners should consider the possibility of posterior capsular opacity, elevated intraocular pressure and amblyopia during follow-up, especially in eyes with microphthalmia and/or associated congenital anomalies. All strabismic children should undergo slit lamp examination prior to strabismus surgery to rule out congenital lens opacities. From a social point of view, equal and fair medical care should be provided to all children regardless of gender. PMID:27621790

  20. [Toxicologic blood emergency screening].

    PubMed

    Cohen, Sabine; Manat, Aurélie; Dumont, Benoit; Bévalot, Fabien; Manchon, Monique; Berny, Claudette

    2010-01-01

    In order to overcome the stop marketing by Biorad company of automated high performance liquid chromatograph with UV detection (Remedi), we developed a gas chromatography-mass spectrometry (GC-MS) to detect and to give an approximation of the overdose of molecules frequently encountered in drug intoxications. Therefore two hundred eighty seventeen blood samples were collected over a period of one year and allowed us to evaluate and compare the performance of these two techniques. As identification, GC-MS does not identify all molecules detected by Remedi in 24.2% of cases; there is a lack of sensitivity for opiates and the systematic absence of certain molecules such as betablockers. However, in 75.8% of cases the GC-MS detects all molecules found by Remedi and other molecules such as meprobamate, paracetamol, benzodiazepines and phenobarbital. The concentrations obtained are interpreted in terms of overdose showed 15.7% of discrepancy and 84.3% of concordance between the two techniques. The GC-MS technique described here is robust, fast and relatively simple to implement; the identification is facilitated by macro commands and the semi quantification remains manual. Despite a sequence of cleaning the column after each sample, carryover of a sample to the next remains possible. This technique can be used for toxicologic screening in acute intoxications. Nevertheless it must be supplemented by a HPLC with UV detection if molecules such as betablockers are suspected. PMID:20348049

  1. Dysphonia risk screening protocol

    PubMed Central

    Nemr, Katia; Simões-Zenari, Marcia; da Trindade Duarte, João Marcos; Lobrigate, Karen Elena; Bagatini, Flavia Alves

    2016-01-01

    OBJECTIVE: To propose and test the applicability of a dysphonia risk screening protocol with score calculation in individuals with and without dysphonia. METHOD: This descriptive cross-sectional study included 365 individuals (41 children, 142 adult women, 91 adult men and 91 seniors) divided into a dysphonic group and a non-dysphonic group. The protocol consisted of 18 questions and a score was calculated using a 10-cm visual analog scale. The measured value on the visual analog scale was added to the overall score, along with other partial scores. Speech samples allowed for analysis/assessment of the overall degree of vocal deviation and initial definition of the respective groups and after six months, the separation of the groups was confirmed using an acoustic analysis. RESULTS: The mean total scores were different between the groups in all samples. Values ranged between 37.0 and 57.85 in the dysphonic group and between 12.95 and 19.28 in the non-dysphonic group, with overall means of 46.09 and 15.55, respectively. High sensitivity and specificity were demonstrated when discriminating between the groups with the following cut-off points: 22.50 (children), 29.25 (adult women), 22.75 (adult men), and 27.10 (seniors). CONCLUSION: The protocol demonstrated high sensitivity and specificity in differentiating groups of individuals with and without dysphonia in different sample groups and is thus an effective instrument for use in voice clinics. PMID:27074171

  2. Congenital Cataract Screening

    PubMed Central

    Rajavi, Zhale; Sabbaghi, Hamideh

    2016-01-01

    Congenital cataract is a leading cause of visual deprivation which can damage the developing visual system of a child; therefore early diagnosis, management and long-term follow-up are essential. It is recommended that all neonates be screened by red reflex examination at birth and suspected cases be referred to ophthalmic centers. Early surgery (<6 weeks of age, based on general neonatal health) is important for achieving the best visual outcome particularly in unilateral cases. In bilateral cases, surgery is highly recommended before appearance of strabismus or nystagmus (<10 weeks of age) with no longer than a one-week interval between the fellow eyes. Parents should be informed that surgery is a starting point and not the endpoint of treatment. Appropriate postoperative management including immediate optical correction in the form of aphakic glasses or contact lenses, or intraocular lens (IOL) implantation at the appropriate age (>1 year) is highly recommended. After surgery, amblyopia treatment and periodic follow-up examinations should be started as soon as possible to achieve a satisfactory visual outcome. Practitioners should consider the possibility of posterior capsular opacity, elevated intraocular pressure and amblyopia during follow-up, especially in eyes with microphthalmia and/or associated congenital anomalies. All strabismic children should undergo slit lamp examination prior to strabismus surgery to rule out congenital lens opacities. From a social point of view, equal and fair medical care should be provided to all children regardless of gender.

  3. Data Quality Screening Service

    NASA Technical Reports Server (NTRS)

    Strub, Richard; Lynnes, Christopher; Hearty, Thomas; Won, Young-In; Fox, Peter; Zednik, Stephan

    2013-01-01

    A report describes the Data Quality Screening Service (DQSS), which is designed to help automate the filtering of remote sensing data on behalf of science users. Whereas this process often involves much research through quality documents followed by laborious coding, the DQSS is a Web Service that provides data users with data pre-filtered to their particular criteria, while at the same time guiding the user with filtering recommendations of the cognizant data experts. The DQSS design is based on a formal semantic Web ontology that describes data fields and the quality fields for applying quality control within a data product. The accompanying code base handles several remote sensing datasets and quality control schemes for data products stored in Hierarchical Data Format (HDF), a common format for NASA remote sensing data. Together, the ontology and code support a variety of quality control schemes through the implementation of the Boolean expression with simple, reusable conditional expressions as operands. Additional datasets are added to the DQSS simply by registering instances in the ontology if they follow a quality scheme that is already modeled in the ontology. New quality schemes are added by extending the ontology and adding code for each new scheme.

  4. Developing a behavioral health screening program for BSL-4 laboratory workers at the National Institutes of Health.

    PubMed

    Skvorc, Casey; Wilson, Deborah E

    2011-03-01

    The events and aftermath of September 11, 2001, accelerated a search for personnel reliability test measures to identify individuals who could pose a threat to our nation's security and safety. The creation and administration of a behavioral health screen for BSL-4 laboratory workers at the National Institutes of Health represents a pioneering effort to proactively build a BSL-4 safety culture promoting worker cohesiveness, trust, respect, and reliability with a balance of worker privacy and public safety. PMID:21361798

  5. Is screen-and-treat approach suited for screening and management of precancerous cervical lesions in Sub-Saharan Africa?

    PubMed

    Fokom-Domgue, Joël; Vassilakos, Pierre; Petignat, Patrick

    2014-08-01

    The World Health Organization guidelines for screening and management of cervical precancerous lesions updated in 2013 made an emphasis on the use of the 'screen-and-treat' approach for cervical cancer prevention. In order to facilitate scaling-up in low income settings, most of these screen-and-treat strategies do not involve confirmatory biopsy. This yields a certain rate of overtreatment. In other words, a majority of people undergoing screen-and-treat intervention who are treated does not necessarily benefit from the treatment. Therefore, the issue of potential short term and long term complications of the recommended treatment procedures (cryotherapy and Loop Electrosurgical Excision Procedure) arises. This question has seldom been studied in resource poor countries, particularly in Sub-Saharan Africa where Human Immunodeficiency Virus infection is rampant in an epidemic fashion and where the procreative capacities are socially rewarding for women. We draw the attention of the scientific community and policy makers to the fact that the lack of evidence supporting the safety of these treatment procedures in African populations may have an impact on the acceptability of these strategies and therefore on the effectiveness of screening programs. PMID:24879892

  6. National Newborn Screening and Genetics Resource Center

    MedlinePlus

    ... GENERAL INFORMATION Conditions Screened by US Programs General Resources Genetics Birth Defects Hearing Screening FOR PROFESSIONALS ACT Sheets(ACMG) General Resources Newborn Screening Genetics Birth Defects FOR FAMILIES FAQs ...

  7. Risk Profiling May Improve Lung Cancer Screening

    Cancer.gov

    A new modeling study suggests that individualized, risk-based selection of ever-smokers for lung cancer screening may prevent more lung cancer deaths and improve the effectiveness and efficiency of screening compared with current screening recommendations

  8. Missouri Elementary Science Safety Manual.

    ERIC Educational Resources Information Center

    Lemons, Judith L.

    The purpose of this safety manual is to provide a resource to help manage and minimize potential risks in science classrooms where students spend up to 60% of instructional time engaged in hands-on activities. Information on general laboratory safety, science equipment safety, safety with plants, safety with animals, safety with chemicals, field…

  9. Safety and the Human Factor.

    ERIC Educational Resources Information Center

    Smith, Ann

    1982-01-01

    Discusses four elements of safety programs: (1) safety training; (2) safety inspections; (3) accident investigations; and (4) protective safety equipment. Also discusses safety considerations in water/wastewater treatment facilities focusing on falls, drowning hazards, trickling filters, confined space entry, collection/distribution system safety,…

  10. Principles of Safety Pharmacology

    PubMed Central

    Pugsley, M K; Authier, S; Curtis, M J

    2008-01-01

    Safety Pharmacology is a rapidly developing discipline that uses the basic principles of pharmacology in a regulatory-driven process to generate data to inform risk/benefit assessment. The aim of Safety Pharmacology is to characterize the pharmacodynamic/pharmacokinetic (PK/PD) relationship of a drug's adverse effects using continuously evolving methodology. Unlike toxicology, Safety Pharmacology includes within its remit a regulatory requirement to predict the risk of rare lethal events. This gives Safety Pharmacology its unique character. The key issues for Safety Pharmacology are detection of an adverse effect liability, projection of the data into safety margin calculation and finally clinical safety monitoring. This article sets out to explain the drivers for Safety Pharmacology so that the wider pharmacology community is better placed to understand the discipline. It concludes with a summary of principles that may help inform future resolution of unmet needs (especially establishing model validation for accurate risk assessment). Subsequent articles in this issue of the journal address specific aspects of Safety Pharmacology to explore the issues of model choice, the burden of proof and to highlight areas of intensive activity (such as testing for drug-induced rare event liability, and the challenge of testing the safety of so-called biologics (antibodies, gene therapy and so on.). PMID:18604233

  11. EDITORIAL: Safety aspects of fusion power plants

    NASA Astrophysics Data System (ADS)

    Kolbasov, B. N.

    2007-07-01

    importance for the fusion power plant research programmes. The objective of this Technical Meeting was to examine in an integrated way all the safety aspects anticipated to be relevant to the first fusion power plant prototype expected to become operational by the middle of the century, leading to the first generation of economically viable fusion power plants with attractive S&E features. After screening by guest editors and consideration by referees, 13 (out of 28) papers were accepted for publication. They are devoted to the following safety topics: power plant safety; fusion specific operational safety approaches; test blanket modules; accident analysis; tritium safety and inventories; decommissioning and waste. The paper `Main safety issues at the transition from ITER to fusion power plants' by W. Gulden et al (EU) highlights the differences between ITER and future fusion power plants with magnetic confinement (off-site dose acceptance criteria, consequences of accidents inside and outside the design basis, occupational radiation exposure, and waste management, including recycling and/or final disposal in repositories) on the basis of the most recent European fusion power plant conceptual study. Ongoing S&E studies within the US inertial fusion energy (IFE) community are focusing on two design concepts. These are the high average power laser (HAPL) programme for development of a dry-wall, laser-driven IFE power plant, and the Z-pinch IFE programme for the production of an economically-attractive power plant using high-yield Z-pinch-driven targets. The main safety issues related to these programmes are reviewed in the paper `Status of IFE safety and environmental activities in the US' by S. Reyes et al (USA). The authors propose future directions of research in the IFE S&E area. In the paper `Recent accomplishments and future directions in the US Fusion Safety & Environmental Program' D. Petti et al (USA) state that the US fusion programme has long recognized that the S

  12. Traceability of Software Safety Requirements in Legacy Safety Critical Systems

    NASA Technical Reports Server (NTRS)

    Hill, Janice L.

    2007-01-01

    How can traceability of software safety requirements be created for legacy safety critical systems? Requirements in safety standards are imposed most times during contract negotiations. On the other hand, there are instances where safety standards are levied on legacy safety critical systems, some of which may be considered for reuse for new applications. Safety standards often specify that software development documentation include process-oriented and technical safety requirements, and also require that system and software safety analyses are performed supporting technical safety requirements implementation. So what can be done if the requisite documents for establishing and maintaining safety requirements traceability are not available?

  13. [Comparison of screens and screen-film-systems (author's transl)].

    PubMed

    Maurer, H J; Goos, F

    1979-06-01

    Important details are to be payed attention in comparison of different scrreens resp. screen-film-systems: 1. Physical characteristics of different groups of luminescent materials: f.i. calcium tung-state, rare-earths compounds, double halogenides. - 2. Different types of screens: highest details up to highest speed intensifying screens, have to be defined more specifically and differentiated against to each other too. - 3. Besides intensification, resolution has to be included into consideration since one of these dates alone does not allow any statement on the total function of a screen or a screen-film-system. - 4. The technical methodological conditions of apparatuses, object and its positioning have to be defined, f.i. X-ray quality, distances, grid, and in automatically controlled exposition, if necessary, position of ionization chamber as well as absorption of cassetts and screen. - 5. Considering these points gradation curves have to include the whole necessary or interesting diagnostic range. - 6. Due to functional correlation between intensification and resolution, the resolution has to be taken in consideration due to application; its interdependence of density and object (f.i. scattered radiation) is often not taken enough in consideration. PMID:461776

  14. Women with Disabilities and Breast Cancer Screening

    MedlinePlus

    ... and Reasonable Accommodations (RA) Women with Disabilities and Breast Cancer Screening Recommend on Facebook Tweet Share Compartir Finding Breast Cancer Early Can Save Lives Disabilities & Breast Cancer Screening ...

  15. Screening for Open Neural Tube Defects.

    PubMed

    Krantz, David A; Hallahan, Terrence W; Carmichael, Jonathan B

    2016-06-01

    Biochemical prenatal screening was initiated with the use of maternal serum alpha fetoprotein to screen for open neural tube defects. Screening now includes multiple marker and sequential screening protocols involving serum and ultrasound markers to screen for aneuploidy. Recently cell-free DNA screening for aneuploidy has been initiated, but does not screen for neural tube defects. Although ultrasound is highly effective in identifying neural tube defects in high-risk populations, in decentralized health systems maternal serum screening still plays a significant role. Abnormal maternal serum alpha fetoprotein alone or in combination with other markers may indicate adverse pregnancy outcome in the absence of open neural tube defects. PMID:27235920

  16. Thermal reactor safety

    SciTech Connect

    Not Available

    1980-06-01

    Information is presented concerning new trends in licensing; seismic considerations and system structural behavior; TMI-2 risk assessment and thermal hydraulics; statistical assessment of potential accidents and verification of computational methods; issues with respect to improved safety; human factors in nuclear power plant operation; diagnostics and activities in support of recovery; LOCA transient analysis; unresolved safety issues and other safety considerations; and fission product transport.

  17. Hydrogen Technologies Safety Guide

    SciTech Connect

    Rivkin, C.; Burgess, R.; Buttner, W.

    2015-01-01

    The purpose of this guide is to provide basic background information on hydrogen technologies. It is intended to provide project developers, code officials, and other interested parties the background information to be able to put hydrogen safety in context. For example, code officials reviewing permit applications for hydrogen projects will get an understanding of the industrial history of hydrogen, basic safety concerns, and safety requirements.

  18. TWRS safety management plan

    SciTech Connect

    Popielarczyk, R.S., Westinghouse Hanford

    1996-08-01

    The Tank Waste Remediation System (TWRS) Safety Management Program Plan for development, implementation and maintenance of the tank farm authorization basis is described. The plan includes activities and procedures for: (a) Updating the current Interim Safety Basis, (b) Development,implementation and maintenance of a Basis for Interim Operations, (c) Development, implementation and maintenance of the Final Safety Analyses Report, (d) Development and implementation of a TWRS information Management System for monitoring the authorization basis.

  19. Screening for Chronic Kidney Disease

    MedlinePlus

    ... enough evidence to determine the potential benefits and harms of screening all adults for CKD. This fact ... waste out of the blood. Potential Benefits and Harms The Task Force examined the evidence to see ...

  20. Luminescent screen composition and apparatus

    NASA Technical Reports Server (NTRS)

    Hilborn, E. H.

    1970-01-01

    Ultraviolet light projects photographically produced images on a screen composed of a mixture of linear and nonlinear phosphors whose spectral emissions are different. This allows the display of polychromatic luminescent images, which gives better discrimination of the objects being viewed.

  1. Recommended Screenings for Women 50+

    MedlinePlus

    ... or peritoneal cancer, talk with your doctor or nurse about your family history. Women with a strong ... had a hysterectomy, talk with your doctor or nurse about whether you still need to be screened. ...

  2. Tuning Forks and Monitor Screens.

    ERIC Educational Resources Information Center

    Harrison, M. A. T.

    2000-01-01

    Defines the vibrations of a tuning fork against a computer monitor screen as a pattern that can illustrate or explain physical concepts like wave vibrations, wave forms, and phase differences. Presents background information and demonstrates the experiment. (Author/YDS)

  3. Screening Newborns' Hearing Now Standard

    MedlinePlus

    ... this page please turn Javascript on. Feature: Taste, Smell, Hearing, Language, Voice, Balance Screening Newborns' Hearing Now ... emailing NIDCDinfo@nidcd.nih.gov . Read More "Taste, Smell, Hearing, Language, Voice, Balance" Articles At Last: A ...

  4. First Trimester Down Syndrome Screen

    MedlinePlus

    ... Home Visit Global Sites Search Help? First Trimester Down Syndrome Screen Share this page: Was this page helpful? ... is carrying has a chromosomal abnormality such as Down syndrome (trisomy 21) or Edwards syndrome (trisomy 18) . The ...

  5. Women who decline breast screening.

    PubMed

    Maclean, U; Sinfield, D; Klein, S; Harnden, B

    1984-12-01

    The health related behaviour and attitudes of a random sample of 125 women aged 45-64 who declined to accept an invitation to attend a breast screening clinic are described. The women differed from attenders in their socioeconomic class and in their customary use of measures to promote health. They were basically unsympathetic towards the idea of screening and the invitation had caused them considerable anxiety. Policy implications are raised. PMID:6512479

  6. Women who decline breast screening.

    PubMed Central

    Maclean, U; Sinfield, D; Klein, S; Harnden, B

    1984-01-01

    The health related behaviour and attitudes of a random sample of 125 women aged 45-64 who declined to accept an invitation to attend a breast screening clinic are described. The women differed from attenders in their socioeconomic class and in their customary use of measures to promote health. They were basically unsympathetic towards the idea of screening and the invitation had caused them considerable anxiety. Policy implications are raised. PMID:6512479

  7. Screening proteins for NMR suitability

    PubMed Central

    Yee, Adelinda A.; Semesi, Anthony; Garcia, Maite; Arrowsmith, Cheryl H.

    2014-01-01

    Summary NMR spectroscopy is an invaluable tool in structural genomics. Identification of protein samples that are amenable to structure determination by NMR spectroscopy requires efficient screening. Here, we describe how we prepare multiple samples in parallel and screen by NMR. The method described here is applicable to large structural genomics projects but can easily be scaled down for application to small structural biology projects since all the equipments used are those commonly found in any NMR structural biology laboratory. PMID:24590717

  8. Vision Screening by Color Photography

    NASA Technical Reports Server (NTRS)

    Jayroe, R.; Richardson, J. R.; Kerr, J.; Hay, S.; Mcbride, R.

    1985-01-01

    Screening test developed for detecting a range of vision defects in eye, including common precursors to amblyopia. Test noninvasive, safe, and administered easily in field by operator with no medical training. Only minimal momentary cooperation of subject required: Thus, test shows promise for use with very young children. Test produces color-slide images of retinas of eyes under specially-controlled lighting conditions. Trained observer screens five children per minute.

  9. Technical Seminar: "Crash Safety"""

    NASA Video Gallery

    This seminar addresses the history and successful progress in predicting and improving the crash safety characteristics of vehicles, with particular emphasis on rotary wing aircraft and composite s...

  10. Lift truck safety review

    SciTech Connect

    Cadwallader, L.C.

    1997-03-01

    This report presents safety information about powered industrial trucks. The basic lift truck, the counterbalanced sit down rider truck, is the primary focus of the report. Lift truck engineering is briefly described, then a hazard analysis is performed on the lift truck. Case histories and accident statistics are also given. Rules and regulations about lift trucks, such as the US Occupational Safety an Health Administration laws and the Underwriter`s Laboratories standards, are discussed. Safety issues with lift trucks are reviewed, and lift truck safety and reliability are discussed. Some quantitative reliability values are given.

  11. Aerospace Safety Advisory Panel

    NASA Technical Reports Server (NTRS)

    1992-01-01

    The results of the Panel's activities are presented in a set of findings and recommendations. Highlighted here are both improvements in NASA's safety and reliability activities and specific areas where additional gains might be realized. One area of particular concern involves the curtailment or elimination of Space Shuttle safety and reliability enhancements. Several findings and recommendations address this area of concern, reflecting the opinion that safety and reliability enhancements are essential to the continued successful operation of the Space Shuttle. It is recommended that a comprehensive and continuing program of safety and reliability improvements in all areas of Space Shuttle hardware/software be considered an inherent component of ongoing Space Shuttle operations.

  12. Helicopter Safety Research

    NASA Technical Reports Server (NTRS)

    Hart, Sandra G.; Rutkowski, Michael

    1999-01-01

    In response to the President's challenge to reduce civil aviation accidents by a factor of 10 by the year 2022, NASA has embarked on an ambitious safety program in partnership with other government agencies and industry. The helicopter element of the NASA initiative has been guided by a series of accident analyses aimed at identifying the most frequent causes and consequences and initiating research to prevent or mitigate these factors. This talk will summarize the key findings of three of the accident analyses, the major elements of the safety program, and how helicopter safety research relates to the safety program.

  13. Newborn Hearing Screening in 2010

    PubMed Central

    Choo, Daniel; Meinzen-Derr, Jareen

    2010-01-01

    Purpose of Review The objectives of this review are to provide the reader with a current and concise review of the data and trends in universal newborn hearing screening(UNHS). Within a relatively short period of time, the concept of screening all infants for hearing loss at the time of birth has evolved from a nascent process to a truly universal system in most developed countries. As a result, the focus and challenges of UNHS have shifted to topics of developing ever more efficient and cost-effective approaches and potentially melding physiologic hearing screenings with ancillary screening techniques. Recent Findings Enhancement of the UNHS process is likely to be accomplished by implementation of novel tools such as wideband reflectance technologies and intelligent incorporation of screening for common genetic and viral causes of congenital hearing loss. Summary With such a rapidly evolving process, it will be critical for clinicians to understand the benefits and limitations of various newborn hearing screening methodologies in order to determine the most appropriate management of children referred from their UNHS. This will entail a working knowledge of emerging audiologic tools as well as infectious and genetic etiologies of pediatric hearing loss. PMID:20808221

  14. Lung cancer screening and management.

    PubMed

    Jones, G S; Baldwin, D R

    2015-12-01

    Deaths from lung cancer are greater than for any other type of malignancy. Many people present with advanced stage cancer at diagnosis and survival is limited. Low radiation dose CT (LDCT) screening appears to offer part of the solution to this. The US National Lung Screening Trial (NLST) showed a 20% reduction in cancer related mortality and a 6.7% reduction in all cause mortality in patients who had LDCT compared to chest X-ray. Lung Cancer screening is now being implemented in the US using the NLST screening criteria but many questions remain about the details of the methodology of screening and its cost effectiveness. Many of these questions are being answered by ongoing European trials that are reporting their findings. In this review we objectively analyse current research evidence and explore the issues that need to be resolved before implementation, including technical considerations, selection criteria and effective nodule management protocols. We discuss the potential barriers that will be faced when beginning a national screening programme and possible solutions to them. PMID:26605556

  15. Integrating antenatal Down's syndrome screening.

    PubMed

    Cuckle, H

    2001-04-01

    Statistical modelling is used to predict screening detection and false-positive rates for policies using different marker combinations and screening modalities. Parameters are derived wherever possible from meta-analyses. Screening with four serum markers yields a similar detection rate in the first trimester as it does in the second, and both have a similar detection rate to that of ultrasound nuchal translucency screening. Ultrasound anomaly screening has a low detection rate. The integration of the different screening modalities can yield very high detection rates. Some methods of integration are preferable to others. The concurrent use of first trimester serum markers and ultrasound nuchal translucency is the most practical. The combination of three modalities with nondisclosure of the intermediate results is more efficient, but the gain in detection is too small to warrant the wait for up to 4 weeks for results. The sequential use of modalities with intermediate disclosure is more practical but will generate higher false-positive rates. PMID:11315873

  16. Cryogenic Capillary Screen Heat Entrapment

    NASA Technical Reports Server (NTRS)

    Bolshinskiy, L.G.; Hastings, L.J.; Stathman, G.

    2007-01-01

    Cryogenic liquid acquisition devices (LADs) for space-based propulsion interface directly with the feed system, which can be a significant heat leak source. Further, the accumulation of thermal energy within LAD channels can lead to the loss of sub-cooled propellant conditions and result in feed system cavitation during propellant outflow. Therefore, the fundamental question addressed by this program was: "To what degree is natural convection in a cryogenic liquid constrained by the capillary screen meshes envisioned for LADs.?"Testing was first conducted with water as the test fluid, followed by LN2 tests. In either case, the basic experimental approach was to heat the bottom of a cylindrical column of test fluid to establish stratification patterns measured by temperature sensors located above and below a horizontal screen barrier position. Experimentation was performed without barriers, with screens, and with a solid barrier. The two screen meshes tested were those typically used by LAD designers, "200x1400" and "325x2300", both with Twill Dutch Weave. Upon consideration of both the water and LN2 data it was concluded that heat transfer across the screen meshes was dependent upon barrier thermal conductivity and that the capillary screen meshes were impervious to natural convection currents.

  17. The Family Context of Low-Income Parents Who Restrict Child Screen Time

    PubMed Central

    Jurkowski, Janine M.; Davison, Kirsten K.

    2013-01-01

    Abstract Background The American Academy of Pediatrics recommends that parents restrict child screen time to two hours per day, but many preschool-aged children exceed this viewing recommendation. Modifying children's viewing habits will require collaborating with parents, but little is known about the factors that influence parents' capacity for effective screen-related parenting. This study aimed to identify the demographic, family and community contextual factors associated with low-income parents' restriction of child screen time. Methods Parents (N=146) of children (age 2–5 years) attending Head Start centers in the United States completed a self-report survey in 2010 assessing parent and child screen use (television, DVD, video, video games, and leisure-time computer use), parent restriction of child screen time, and family (parent stress, social support, and life pressures) and community (neighborhood safety and social capital) factors. Results Children were more likely to meet the American Academy of Pediatrics screen time recommendation if their parent reported high restriction of child screen time. Parent and child demographic characteristics were not associated with parents' restriction of child screen time. In multivariate analysis, less parent screen time, fewer parent life pressures, and greater social support were associated with parents' high restriction of screen time. Conclusion Family contextual factors may play an important role in enabling low-income parents to restrict their children's screen time. When counseling low-income parents about the importance of restricting child screen time, practitioners should be sensitive to family contextual factors that may influence parents' capacity to implement this behavior change. PMID:24004326

  18. A Silent Safety Program

    NASA Technical Reports Server (NTRS)

    Goodin, James Ronald

    2006-01-01

    NASA's Columbia Accident Investigation Board (CAIB) referred 8 times to the NASA "Silent Safety Program." This term, "Silent Safety Program" was not an original observation but first appeared in the Rogers Commission's Investigation of the Challenger Mishap. The CAIB on page 183 of its report in the paragraph titled 'Encouraging Minority Opinion,' stated "The Naval Reactor Program encourages minority opinions and "bad news." Leaders continually emphasize that when no minority opinions are present, the responsibility for a thorough and critical examination falls to management. . . Board interviews revealed that it is difficult for minority and dissenting opinions to percolate up through the agency's hierarchy. . ." The first question and perhaps the only question is - what is a silent safety program? Well, a silent safety program may be the same as the dog that didn't bark in Sherlock Holmes' "Adventure of the Silver Blaze" because system safety should behave as a devil's advocate for the program barking on every occasion to insure a critical review inclusion. This paper evaluates the NASA safety program and provides suggestions to prevent the recurrence of the silent safety program alluded to in the Challenger Mishap Investigation. Specifically targeted in the CAM report, "The checks and balances the safety system was meant to provide were not working." A silent system safety program is not unique to NASA but could emerge in any and every organization. Principles developed by Irving Janis in his book, Groupthink, listed criteria used to evaluate an organization's cultural attributes that allows a silent safety program to evolve. If evidence validates Jams's criteria, then Jams's recommendations for preventing groupthink can also be used to improve a critical evaluation and thus prevent the development of a silent safety program.

  19. Highway Safety Program Manual: Volume 3: Motorcycle Safety.

    ERIC Educational Resources Information Center

    National Highway Traffic Safety Administration (DOT), Washington, DC.

    Volume 3 of the 19-volume Highway Safety Program Manual (which provides guidance to State and local governments on preferred highway safety practices) concentrates on aspects of motorcycle safety. The purpose and specific objectives of a State motorcycle safety program are outlined. Federal authority in the highway safety area and general policies…

  20. Safety for Older Consumers. Home Safety Checklist.

    ERIC Educational Resources Information Center

    Consumer Product Safety Commission, Washington, DC.

    A home safety checklist geared to the needs of older adults is presented in this document. The beginning of the checklist highlights potential hazards which may need to be checked in more than one area of the home, such as electric cords, smoke detectors, rugs, telephone areas, and emergency exit plans. The rest of the checklist is organized…

  1. Safety and Excellence. Safety in the Schools

    ERIC Educational Resources Information Center

    Merrow, John

    2004-01-01

    As far as schools are concerned, there are three kinds of safety: physical, emotional, and intellectual. Excellence demands all three, while "good enough" schools are simply physically safe. How can parents and others determine whether a school is physically safe? It's always good to find out how many students were suspended at a particular…

  2. Bicycle Safety in Action.

    ERIC Educational Resources Information Center

    National Commission on Safety Education, Washington, DC.

    This material was designed to assist schools in teaching bicycle safety. As the population grows and competition for road space increases, it is more imperative than ever that we concentrate attention on the need for caution among pupil cyclists. The pamphlet: (1) discusses the role of bicycle safety in classroom instruction and in student…

  3. Improving Student Safety.

    ERIC Educational Resources Information Center

    Dorn, Michael; Trump, Kenneth S.; Nichols, R. Leslie

    2001-01-01

    Presents the latest information on how schools can keep their students safe. Safety oriented actions discussed cover incident reporting and tracking, tactical site surveys, school safety and emergency operations planning, staff development efforts, and facility design. Explains the need to review and test specific prevention concepts and emergency…

  4. Introducing Laboratory Safety.

    ERIC Educational Resources Information Center

    DeLorenzo, Ronald

    1985-01-01

    Presents a simple, 10-item quiz designed to make students aware that they must learn laboratory safety. The items include questions on acid/base accidents, several types of fire extinguishers, and safety glassses. Answers and some explanations are included. (DH)

  5. Idaho Safety Manual.

    ERIC Educational Resources Information Center

    Idaho State Dept. of Education, Boise. Div. of Vocational Education.

    This manual is intended to help teachers, administrators, and local school boards develop and institute effective safety education as a part of all vocational instruction in the public schools of Idaho. This guide is organized in 13 sections that cover the following topics: introduction to safety education, legislation, levels of responsibility,…

  6. Science Safety Procedure Handbook.

    ERIC Educational Resources Information Center

    Lynch, Mervyn A.; Offet, Lorna

    This booklet outlines general safety procedures in the areas of: (1) student supervision; (2) storage safety regulations, including lists of incompatible chemicals, techniques of disposal and storage; (3) fire; and (4) first aid. Specific sections exist for elementary, junior high school, senior high school, in which special procedures are…

  7. Workplace Health and Safety.

    ERIC Educational Resources Information Center

    Massachusetts Career Development Inst., Springfield.

    This booklet is one of six texts from a workplace literacy curriculum designed to assist learners in facing the increased demands of the workplace. It is a short guide to workplace health and safety issues, laws, and regulations, especially in Massachusetts. Topics covered include the following: (1) safety issues--workplace ergonomics, the…

  8. Radiological Safety Handbook.

    ERIC Educational Resources Information Center

    Army Ordnance Center and School, Aberdeen Proving Ground, MD.

    Written to be used concurrently with the U.S. Army's Radiological Safety Course, this publication discusses the causes, sources, and detection of nuclear radiation. In addition, the transportation and disposal of radioactive materials are covered. The report also deals with the safety precautions to be observed when working with lasers, microwave…

  9. Serving Up Safety.

    ERIC Educational Resources Information Center

    Fitzgerald, Patricia L.

    2002-01-01

    Describes what principals can do to protect children from food-related illness in school: Forming of food-safe school teams, developing food-safety procedures, including food safety in crises-management plans, educating staff on plans and procedures, encouraging hand washing, making sure the cafeteria works properly, and encouraging the hiring of…

  10. A Silent Safety Program

    NASA Astrophysics Data System (ADS)

    Goodin, James Ronald

    2010-09-01

    NASA's Columbia Accident Investigation Board(CAIB) referred 8 times to the NASA “Silent Safety Program.” This term, “Silent Safety Program” was not an original observation but first appeared in the Rogers Commission's Investigation of the Challenger Mishap.

  11. School Safety and Security.

    ERIC Educational Resources Information Center

    California State Dept. of Education, Sacramento.

    This document offers additional guidelines for school facilities in California in the areas of safety and security, lighting, and cleanliness. It also offers a description of technology resources available on the World Wide Web. On the topic of safety and security, the document offers guidelines in the areas of entrances, doors, and controlled…

  12. Roads to Safety.

    ERIC Educational Resources Information Center

    Hauer, Ezra

    1991-01-01

    Contends that the level of safety built into roads is largely unpremeditated and that roads and highways are not as safe as they might be. Discusses practices, standards, and deficiencies in highway and traffic safety related to geometric design and traffic engineering. Recommends increased transportation engineering professionalism and public…

  13. Safety Precautions for Science.

    ERIC Educational Resources Information Center

    Folks, John; And Others

    Safety information is discussed and outlined in this guide. Areas include: (1) general laboratory safety rules; (2) general rules and guidelines for animals in the elementary classroom; (3) general guidelines for the physical sciences; (4) general rules for using animals in investigations, with specifics on the care and handling of mammals,…

  14. The color of safety

    SciTech Connect

    Carter, R.A.

    2006-06-15

    The industry's workforce is getting grayer as veteran miners approach retirement, and greener as new hires come onboard. Will the changing complexion of the industry affect future safety technology? The article discusses problems of noise, vibration, and communication faced by coal miners and reports some developments by manufacturers of mining equipment to improve health and safety. 1 fig., 4 photos.

  15. Safety in Aquaculture

    ERIC Educational Resources Information Center

    Durborow, Robert M.; Myers, Melvin L.

    2016-01-01

    In this article, occupational safety interventions for agriculture-related jobs, specifically in aquaculture, are reviewed. Maintaining quality of life and avoiding economic loss are two areas in which aquaculturists can benefit by incorporating safety protocols and interventions on their farms. The information in this article is based on farm…

  16. Querying Safety Cases

    NASA Technical Reports Server (NTRS)

    Denney, Ewen W.; Naylor, Dwight; Pai, Ganesh

    2014-01-01

    Querying a safety case to show how the various stakeholders' concerns about system safety are addressed has been put forth as one of the benefits of argument-based assurance (in a recent study by the Health Foundation, UK, which reviewed the use of safety cases in safety-critical industries). However, neither the literature nor current practice offer much guidance on querying mechanisms appropriate for, or available within, a safety case paradigm. This paper presents a preliminary approach that uses a formal basis for querying safety cases, specifically Goal Structuring Notation (GSN) argument structures. Our approach semantically enriches GSN arguments with domain-specific metadata that the query language leverages, along with its inherent structure, to produce views. We have implemented the approach in our toolset AdvoCATE, and illustrate it by application to a fragment of the safety argument for an Unmanned Aircraft System (UAS) being developed at NASA Ames. We also discuss the potential practical utility of our query mechanism within the context of the existing framework for UAS safety assurance.

  17. Introduction to Safety

    ERIC Educational Resources Information Center

    Church, Ellen Booth

    2005-01-01

    This article discusses summertime safety activities for children. As children participate in the summer safety activities, they learn how to identify problems and communicate their ideas and feelings about potentially dangerous situations. They learn how to think through the problem and create solutions. The author presents a few ideas to go with…

  18. Safety in the Artroom.

    ERIC Educational Resources Information Center

    Qualley, Charles A.

    This book provides information about health and safety hazards in art classrooms. The book outlines a practical plan for an art room safety program. It includes recommendations for providing protective equipment and enlisting students' active participation. Included are sample worksheets and checklists, explanations of legal liability, and…

  19. Biology Laboratory Safety Manual.

    ERIC Educational Resources Information Center

    Case, Christine L.

    The Centers for Disease Control (CDC) recommends that schools prepare or adapt a biosafety manual, and that instructors develop a list of safety procedures applicable to their own lab and distribute it to each student. In this way, safety issues will be brought to each student's attention. This document is an example of such a manual. It contains…

  20. Implementing Hearing Safety

    ERIC Educational Resources Information Center

    Cliffe, Roger

    1978-01-01

    Hearing damage from noise exposure and approaches to implementing hearing safety in school industrial laboratories through noise reduction and protective equipment are discussed. Although all states have not adopted the Occupational Safety and Health Act, teachers should be aware of noise hazards and act to protect hearing. (MF)

  1. Child Transportation Safety Tips.

    ERIC Educational Resources Information Center

    National Highway Traffic Safety Administration (DOT), Washington, DC.

    This document presents nine tips regarding safe infant and child transportation, each tip explained in one to two pages. The tips are as follows: (1) quick safety seat checkup; (2) where should your child ride? (3) how to protect your new baby in the car; (4) what safety seat to use for a big baby or toddler? (5) how should preschool and school…

  2. Educating for Safety.

    ERIC Educational Resources Information Center

    Rothe, J. Peter

    1991-01-01

    To enhance the chance for success in educating young drivers, there should be a balance between the content, structure, and goals of traffic safety programs and the normative rules governing young people's lives. Presents recommendations for safety education based on the notion of complementarity and using a multiperspective approach. (AF)

  3. CLAD DEGRADATION - FEPS SCREENING ARGUMENTS

    SciTech Connect

    R. Schreiner

    2004-10-21

    The purpose of this report is to evaluate and document the screening of the clad degradation features, events, and processes (FEPs) with respect to modeling used to support the Total System Performance Assessment-License Application (TSPA-LA). This report also addresses the effect of certain FEPs on both the cladding and the commercial spent nuclear fuel (CSNF), DOE-owned spent nuclear fuel (DSNF), and defense high-level waste (DHLW) waste forms, as appropriate to address the effects on multiple materials and both components (FEPs 2.1.09.09.0A, 2.1.09.11.0A, 2.1.11.05.0A, 2.1.12.02.0A, and 2.1.12.03.0A). These FEPs are expected to affect the repository performance during the postclosure regulatory period of 10,000 years after permanent closure. Table 1-1 provides the list of cladding FEPs, including their screening decisions (include or exclude). The primary purpose of this report is to identify and document the analysis, screening decision, and TSPA-LA disposition (for included FEPs) or screening argument (for excluded FEPs) for these FEPs related to clad degradation. In some cases, where a FEP covers multiple technical areas and is shared with other FEP reports, this report may provide only a partial technical basis for the screening of the FEP. The full technical basis for shared FEPs is addressed collectively by the sharing FEP reports. The screening decisions and associated TSPA-LA dispositions or screening arguments from all of the FEP reports are cataloged in a project-specific FEPs database.

  4. K Basin safety analysis

    SciTech Connect

    Porten, D.R.; Crowe, R.D.

    1994-12-16

    The purpose of this accident safety analysis is to document in detail, analyses whose results were reported in summary form in the K Basins Safety Analysis Report WHC-SD-SNF-SAR-001. The safety analysis addressed the potential for release of radioactive and non-radioactive hazardous material located in the K Basins and their supporting facilities. The safety analysis covers the hazards associated with normal K Basin fuel storage and handling operations, fuel encapsulation, sludge encapsulation, and canister clean-up and disposal. After a review of the Criticality Safety Evaluation of the K Basin activities, the following postulated events were evaluated: Crane failure and casks dropped into loadout pit; Design basis earthquake; Hypothetical loss of basin water accident analysis; Combustion of uranium fuel following dryout; Crane failure and cask dropped onto floor of transfer area; Spent ion exchange shipment for burial; Hydrogen deflagration in ion exchange modules and filters; Release of Chlorine; Power availability and reliability; and Ashfall.

  5. Formalizing Probabilistic Safety Claims

    NASA Technical Reports Server (NTRS)

    Herencia-Zapana, Heber; Hagen, George E.; Narkawicz, Anthony J.

    2011-01-01

    A safety claim for a system is a statement that the system, which is subject to hazardous conditions, satisfies a given set of properties. Following work by John Rushby and Bev Littlewood, this paper presents a mathematical framework that can be used to state and formally prove probabilistic safety claims. It also enables hazardous conditions, their uncertainties, and their interactions to be integrated into the safety claim. This framework provides a formal description of the probabilistic composition of an arbitrary number of hazardous conditions and their effects on system behavior. An example is given of a probabilistic safety claim for a conflict detection algorithm for aircraft in a 2D airspace. The motivation for developing this mathematical framework is that it can be used in an automated theorem prover to formally verify safety claims.

  6. Incorporating Human Dosimetry and Exposure into High-Throughput In Vitro Toxicity Screening

    EPA Science Inventory

    Many chemicals in commerce today have undergone limited or no safety testing. To reduce the number of untested chemicals and prioritize limited testing resources, several governmental programs are using high-throughput in vitro screens for assessing chemical effects across multip...

  7. A High-Throughput Cidality Screen for Mycobacterium Tuberculosis

    PubMed Central

    Kaur, Parvinder; Ghosh, Anirban; Krishnamurthy, Ramya Vadageri; Bhattacharjee, Deepa Gagwani; Achar, Vijayashree; Datta, Santanu; Narayanan, Shridhar; Anbarasu, Anand; Ramaiah, Sudha

    2015-01-01

    Exposure to Mycobacterium tuberculosis (Mtb) aerosols is a major threat to tuberculosis (TB) researchers, even in bio-safety level-3 (BSL-3) facilities. Automation and high-throughput screens (HTS) in BSL3 facilities are essential for minimizing manual aerosol-generating interventions and facilitating TB research. In the present study, we report the development and validation of a high-throughput, 24-well ‘spot-assay’ for selecting bactericidal compounds against Mtb. The bactericidal screen concept was first validated in the fast-growing surrogate Mycobacterium smegmatis (Msm) and subsequently confirmed in Mtb using the following reference anti-tubercular drugs: rifampicin, isoniazid, ofloxacin and ethambutol (RIOE, acting on different targets). The potential use of the spot-assay to select bactericidal compounds from a large library was confirmed by screening on Mtb, with parallel plating by the conventional gold standard method (correlation, r2 = 0.808). An automated spot-assay further enabled an MBC90 determination on resistant and sensitive Mtb clinical isolates. The implementation of the spot-assay in kinetic screens to enumerate residual Mtb after either genetic silencing (anti-sense RNA, AS-RNA) or chemical inhibition corroborated its ability to detect cidality. This relatively simple, economical and quantitative HTS considerably minimized the bio-hazard risk and enabled the selection of novel vulnerable Mtb targets and mycobactericidal compounds. Thus, spot-assays have great potential to impact the TB drug discovery process. PMID:25693161

  8. [Study of screening pseudoallergenic substances of Shuanghuanglian injection].

    PubMed

    Yi, Yan; Zhang, Yu-shi; Li, Chun-ying; Zhao, Hai-yu; Xiao, Hong-bin; Li, Gui-qin; Lu, Yu-ting; Han, Jia-yin; Zhao, Yong; Wang, Hong-jie; Si, Nan; Liang, Ai-hua; Bian, Bao-lin

    2015-07-01

    In this study, chemistry, biology and pharmacology were combinated to screen pseudoallergenic substances of Shuang-huanglian injection (SHLI) so that to establish a scientific and systematic approach to screen pseudoallergenic substances of traditional Chinese medicine injections. The mouse pseudoallergic reaction models were used to screen the pseudoallergic reaction of SHLI's intermediate extract and the intermediate extract's component or ingredient. Among the three intermediates of Shuanghuanglian injection (extract of Scutellaria baicalensis, extract of Lonicera japonica, extract of Forsythia suspensa) , pseudoallergic action of Forsythia suspensa was the strongest, Forsythia suspesnsa's pseudoallergic reaction mainly associated with the composition with largerchemical polarity. Further it was found that forsythiaside A and arctiin which existed in the the composition with largerchemical polarity caused obvious pseudoallergic reactions. SHLI with removal forsythoside A with the technology of HPLC-MS displayed reduced pseudoallergic reaction and a significant improved safety. This study provided a scientific basis for SHLI process improvements and also offered idea and research foundation for screening pseudoallergenic substances injections in other TCM injections. PMID:26666017

  9. 7 CFR 4284.911 - Evaluation screening.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 15 2010-01-01 2010-01-01 false Evaluation screening. 4284.911 Section 4284.911... Evaluation screening. The Agency will conduct an initial screening of all proposals to determine whether the... evaluation criteria will disqualify the proposal. Submissions which do not pass the initial screening may...

  10. 7 CFR 201.32 - Screenings.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Screenings. 201.32 Section 201.32 Agriculture... REGULATIONS Labeling in General § 201.32 Screenings. Screenings shipped in interstate commerce, if in..., shall be invoiced with the words, “Screenings for processing—not for seeding.”...

  11. Newborn Screening for Fragile X Syndrome

    ERIC Educational Resources Information Center

    Bailey, Donald B., Jr.

    2004-01-01

    Newborn screening for fragile X syndrome (FXS) is technically possible, and in the relatively near future accurate and inexpensive screening technologies are likely to be available. When that happens, will America's public health system adopt newborn screening for fragile X syndrome? This article addresses this issue by first placing screening for…

  12. Facila Screening: History and Critical Review.

    ERIC Educational Resources Information Center

    Lutzker, John R.; Wesch, David

    1983-01-01

    The review examines use of facial screening to treat self-injurious behavior and other problem behaviors. A historical chronology of facial screening is presented, along with a review of published articles on facial screening and other visual occlusion techniques. A critical review is offered with suggestions for research with facial screening.…

  13. Planning and Implementing Health Screening Programs.

    ERIC Educational Resources Information Center

    Webster, Katherine P.

    1980-01-01

    School health screening programs, which include screening, education of children and parents, and follow-up in the form of appropriate treatment, are described. A scoliosis screening program is described as an example of the model presented. Suggestions for planners, participants, and evaluators of any school health screening are summarized. (JMF)

  14. Screening on urogenital Chlamydia trachomatis

    PubMed Central

    de Carvalho Gomes, Helena; Velasco-Garrido, Marcial; Busse, Reinhard

    2005-01-01

    Introduction Around 92 million urogenital infections are caused yearly by Chlamydia trachomatis worldwide [1].The overall incidence of sexually transmitted diseases is increasing, as shown by the increases in the number of reported cases of syphilis and gonorrhea [2]. Chlamydia trachomatis infections are associated with various serious diseases in women, men and newborns, which could be, at least partially, avoided by means of early diagnosis and therapy. The Federal Joint Committee - responsible for decision-making concerning the benefit package of the German Social Health Insurance - has publicly announced the starting of deliberations on the issue of screening for Chlamydia trachomatis. Research Questions The leading question to be answered is whether screening for Chlamydia trachomatis should be included in the German benefit basket. The aim of this report is to provide a summary of the available evidence concerning the issue of screening for Chlamydia trachomatis. Methods The summary of published scientific evidence, including HTA reports, systematic reviews, guidelines and primary research is represented. The synthesis follows the structure given by the criteria of Wilson and Jungner [3] for the introduction of screening in a population: relevance of the condition, availability of an adequate test, effectiveness of screening, acceptance of the programme, and economical issues. A literature search was conducted for each aspect of the synthesis and the evidence has been summarised in evidence tables. Results We identified five HTA reports from three European agencies [4], [5], [6], [7] and one from the USA [8]. In addition, we identified four guidelines from Northamerica[9], [10], [11], [12] and one from Europe [13]. A total of 56 primary research publications were included: relevance of the disease (n=26), availability of test (n=1), effectiveness of screening (n=11), acceptance of the programme (n=11), economical issues (n=7). Discussion The main limitation

  15. Rare earth phosphors and phosphor screens

    DOEpatents

    Buchanan, Robert A.; Maple, T. Grant; Sklensky, Alden F.

    1981-01-01

    This invention relates to rare earth phosphor screens for converting image carrying incident radiation to image carrying visible or near-visible radiation and to the rare earth phosphor materials utilized in such screens. The invention further relates to methods for converting image carrying charged particles to image carrying radiation principally in the blue and near-ultraviolet region of the spectrum and to stabilized rare earth phosphors characterized by having a continuous surface layer of the phosphors of the invention. More particularly, the phosphors of the invention are oxychlorides and oxybromides of yttrium, lanthanum and gadolinium activated with trivalent cerium and the conversion screens are of the type illustratively including x-ray conversion screens, image amplifier tube screens, neutron imaging screens, cathode ray tube screens, high energy gamma ray screens, scintillation detector screens and screens for real-time translation of image carrying high energy radiation to image carrying visible or near-visible radiation.

  16. Screening recommendations for the elderly.

    PubMed Central

    Beers, M H; Fink, A; Beck, J C

    1991-01-01

    BACKGROUND. Studies have documented the potential contributions of preventive health care programs. Yet little is known about which screening tests should be included in public health programs for older persons. This study offers recommendations regarding these tests. METHODS. The recommendations come from synthesizing the findings of the US Preventive Services Task Force, the literature, and the consensus of experts in geriatrics, gerontology, and health policy research. The literature was evaluated to identify methodologically sound studies of the prevalence of selected disorders and benefits and availability of screening procedures for those disorders. Experts from various fields specializing in the care of the elderly formed panels to assist in evaluating the literature and providing further information from gerontological and public health perspectives. RESULTS. We recommend vision testing for refractive error; inspection of the skin surface for fungal infection and skin cancer, drug eruptions, and xerosis; a history for symptoms of xerosis; audiometric testing for presbycusis; surveys for hearing loss; otoscopic inspection for cerumen impaction; dental examination for caries; measurement of blood pressure for hypertension; and breast examination and mammography for cancer. CONCLUSIONS. Our study suggests that these screening procedures are useful for public health screening programs. More information is needed on the effects of screening services on the health and functioning of older persons. PMID:1951823

  17. Detection of critical congenital heart defects: Review of contributions from prenatal and newborn screening

    PubMed Central

    Olney, Richard S.; Ailes, Elizabeth C.; Sontag, Marci K.

    2015-01-01

    In 2011, statewide newborn screening programs for critical congenital heart defects began in the United States, and subsequently screening has been implemented widely. In this review, we focus on data reports and collection efforts related to both prenatal diagnosis and newborn screening. Defect-specific, maternal, and geographic factors are associated with variations in prenatal detection, so newborn screening provides a population-wide safety net for early diagnosis. A new web-based repository is collecting information on newborn screening program policies, quality indicators related to screening programs, and specific case-level data on infants with these defects. Birth defects surveillance programs also collect data about critical congenital heart defects, particularly related to diagnostic timing, mortality, and services. Individuals from state programs, federal agencies, and national organizations will be interested in these data to further refine algorithms for screening in normal newborn nurseries, neonatal intensive care settings, and other special populations; and ultimately to evaluate the impact of screening on outcomes. PMID:25979782

  18. Detection of critical congenital heart defects: Review of contributions from prenatal and newborn screening.

    PubMed

    Olney, Richard S; Ailes, Elizabeth C; Sontag, Marci K

    2015-04-01

    In 2011, statewide newborn screening programs for critical congenital heart defects began in the United States, and subsequently screening has been implemented widely. In this review, we focus on data reports and collection efforts related to both prenatal diagnosis and newborn screening. Defect-specific, maternal, and geographic factors are associated with variations in prenatal detection, so newborn screening provides a population-wide safety net for early diagnosis. A new web-based repository is collecting information on newborn screening program policies, quality indicators related to screening programs, and specific case-level data on infants with these defects. Birth defects surveillance programs also collect data about critical congenital heart defects, particularly related to diagnostic timing, mortality, and services. Individuals from state programs, federal agencies, and national organizations will be interested in these data to further refine algorithms for screening in normal newborn nurseries, neonatal intensive care settings, and other special populations; and ultimately to evaluate the impact of screening on outcomes. PMID:25979782

  19. Interim safety basis compliance matrix for Trenches 31 and 34

    SciTech Connect

    Ames, R.R.

    1994-12-30

    The tables provided in this document identify the specific requirements and basis for the administrative controls established in the Westinghouse Hanford Company (WHC) Solid Waste Burial Ground (SWBG) Interim Safety Basis (ISB) for operation of the Project W-025, Mixed Waste Lined Landfill (Trenches 31 and 34). The tables document the necessary controls and implementing procedures to ensure compliance with the requirements of the ISB. These requirements provide a basis for future Unreviewed Safety Questions (USQ) screening of applicable procedure changes, proposed physical modifications, tests, experiments, and occurrences. Table 1 provides the SWBG interim Operational Safety Requirements administrative controls matrix. The specific assumptions and commitments used in the safety analysis documents applicable to disposal of mixed wastes in Trenches 31 and 34 are provided in Table 2. Table 3 is provided to document the potential engineered and administrative mitigating features identified in the Preliminary Hazard Analysis (PHA) for disposal of mixed waste.

  20. Phenotypic Screens in Antimalarial Drug Discovery.

    PubMed

    Hovlid, Marisa L; Winzeler, Elizabeth A

    2016-09-01

    Phenotypic high-throughput screens are a valuable tool for identifying new chemical compounds with antimalarial activity. Traditionally, these screens have focused solely on the symptomatic asexual blood stage of the parasite life cycle; however, to discover new medicines for malaria treatment and prevention, robust screening technologies against other parasite life-cycle stages are required. This review highlights recent advances and progress toward phenotypic screening methodologies over the past several years, with a focus on exoerythrocytic stage screens. PMID:27247245

  1. NASA's Software Safety Standard

    NASA Technical Reports Server (NTRS)

    Ramsay, Christopher M.

    2005-01-01

    NASA (National Aeronautics and Space Administration) relies more and more on software to control, monitor, and verify its safety critical systems, facilities and operations. Since the 1960's there has hardly been a spacecraft (manned or unmanned) launched that did not have a computer on board that provided vital command and control services. Despite this growing dependence on software control and monitoring, there has been no consistent application of software safety practices and methodology to NASA's projects with safety critical software. Led by the NASA Headquarters Office of Safety and Mission Assurance, the NASA Software Safety Standard (STD-18l9.13B) has recently undergone a significant update in an attempt to provide that consistency. This paper will discuss the key features of the new NASA Software Safety Standard. It will start with a brief history of the use and development of software in safety critical applications at NASA. It will then give a brief overview of the NASA Software Working Group and the approach it took to revise the software engineering process across the Agency.

  2. Unique interactive projection display screen

    SciTech Connect

    Veligdan, J.T.

    1997-11-01

    Projection systems continue to be the best method to produce large (1 meter and larger) displays. However, in order to produce a large display, considerable volume is typically required. The Polyplanar Optic Display (POD) is a novel type of projection display screen, which for the first time, makes it possible to produce a large projection system that is self-contained and only inches thick. In addition, this display screen is matte black in appearance allowing it to be used in high ambient light conditions. This screen is also interactive and can be remotely controlled via an infrared optical pointer resulting in mouse-like control of the display. Furthermore, this display need not be flat since it can be made curved to wrap around a viewer as well as being flexible.

  3. Chemical screening with zebrafish embryos.

    PubMed

    Zhong, Hanbing; Lin, Shuo

    2011-01-01

    Functional chemicals are very useful tools for molecular biology studies. Due to its small size, large progeny clutch, and embryonic transparency, zebrafish serves as a superb in vivo animal model for chemical compound screens and characterization. During zebrafish embryogenesis, multiple developmental phenotypes can be easily examined under the microscope, therefore allowing a more comprehensive evaluation for identifying novel functional chemicals than cell-based assays. Ever since the first zebrafish-based chemical screen was conducted in the year 2000, many functional chemicals have been discovered using this strategy. In this chapter, we describe how to perform a typical zebrafish-based chemical screen and discuss the details of the protocol by using the example of the identification and characterization of two new Smo inhibitors with a Gli:GFP transgenic line. PMID:21318908

  4. Microelectroporation device for genomic screening

    SciTech Connect

    Perroud, Thomas D.; Renzi, Ronald F.; Negrete, Oscar; Claudnic, Mark R.

    2014-09-09

    We have developed an microelectroporation device that combines microarrays of oligonucleotides, microfluidic channels, and electroporation for cell transfection and high-throughput screening applications (e.g. RNA interference screens). Microarrays allow the deposition of thousands of different oligonucleotides in microscopic spots. Microfluidic channels and microwells enable efficient loading of cells into the device and prevent cross-contamination between different oligonucleotides spots. Electroporation allows optimal transfection of nucleic acids into cells (especially hard-to-transfect cells such as primary cells) by minimizing cell death while maximizing transfection efficiency. This invention has the advantage of a higher throughput and lower cost, while preventing cross-contamination compared to conventional screening technologies. Moreover, this device does not require bulky robotic liquid handling equipment and is inherently safer given that it is a closed system.

  5. Patient Safety in Surgery

    PubMed Central

    Makary, Martin A.; Sexton, J Bryan; Freischlag, Julie A.; Millman, E Anne; Pryor, David; Holzmueller, Christine; Pronovost, Peter J.

    2006-01-01

    Background: Improving patient safety is an increasing priority for surgeons and hospitals since sentinel events can be catastrophic for patients, caregivers, and institutions. Patient safety initiatives aimed at creating a safe operating room (OR) culture are increasingly being adopted, but a reliable means of measuring their impact on front-line providers does not exist. Methods: We developed a surgery-specific safety questionnaire (SAQ) and administered it to 2769 eligible caregivers at 60 hospitals. Survey questions included the appropriateness of handling medical errors, knowledge of reporting systems, and perceptions of safety in the operating room. MANOVA and ANOVA were performed to compare safety results by hospital and by an individual's position in the OR using a composite score. Multilevel confirmatory factor analysis was performed to validate the structure of the scale at the operating room level of analysis. Results: The overall response rate was 77.1% (2135 of 2769), with a range of 57% to 100%. Factor analysis of the survey items demonstrated high face validity and internal consistency (α = 0.76). The safety climate scale was robust and internally consistent overall and across positions. Scores varied widely by hospital [MANOVA omnibus F (59, 1910) = 3.85, P < 0.001], but not position [ANOVA F (4, 1910) = 1.64, P = 0.16], surgeon (mean = 73.91), technician (mean = 70.26), anesthesiologist (mean = 71.57), CRNA (mean = 71.03), and nurse (mean = 70.40). The percent of respondents reporting good safety climate in each hospital ranged from 16.3% to 100%. Conclusions: Safety climate in surgical departments can be validly measured and varies widely among hospitals, providing the opportunity to benchmark performance. Scores on the SAQ can serve to evaluate interventions to improve patient safety. PMID:16632997

  6. The stability of hexacosanoyl lysophosphatidylcholine in dried-blood spot quality control materials for X-linked adrenoleukodystrophy newborn screening

    PubMed Central

    Haynes, Christopher A.; De Jesús, Víctor R.

    2016-01-01

    Objectives Newborn screening for X-linked adrenoleukodystrophy utilizes tandem mass spectrometry to analyze dried-blood spot specimens. Quality control materials (dried-blood spots enriched with hexacosanoyl lysophosphatidylcholine) were prepared and stored at different temperatures for up to 518 days to evaluate the stability of this biomarker for X-linked adrenoleukodystrophy. Design and methods Dried-blood spot storage included desiccant (45, 171, and 518 days) or omitted desiccant (53 days at >90% relative humidity). Specimens were stored for 171 and 518 days at −20 °C, 4 °C, ambient temperature, and 37 °C. Each weekday for 45 days, a bag of specimens stored at 4 °C was warmed to ambient temperature and one specimen was removed for storage at −80 °C. Specimens were analyzed by high-performance liquid-chromatography electrospray ionization tandem mass spectrometry and data was plotted as concentration (micromoles per liter) vs. time. Linear regression provided slope and y-intercept values for each storage condition. Results Small slope values (0.01 or less) and y-intercept values close to the enrichment indicated less than 11% loss of hexacosanoyl lysophosphatidylcholine under all storage conditions tested. Conclusions Quality control materials for X-linked adrenoleukodystrophy are stable for at least 1 year when stored with desiccant. PMID:25307302

  7. Development and Evaluation of Algorithms for Breath Alcohol Screening

    PubMed Central

    Ljungblad, Jonas; Hök, Bertil; Ekström, Mikael

    2016-01-01

    Breath alcohol screening is important for traffic safety, access control and other areas of health promotion. A family of sensor devices useful for these purposes is being developed and evaluated. This paper is focusing on algorithms for the determination of breath alcohol concentration in diluted breath samples using carbon dioxide to compensate for the dilution. The examined algorithms make use of signal averaging, weighting and personalization to reduce estimation errors. Evaluation has been performed by using data from a previously conducted human study. It is concluded that these features in combination will significantly reduce the random error compared to the signal averaging algorithm taken alone. PMID:27043576

  8. Development and Evaluation of Algorithms for Breath Alcohol Screening.

    PubMed

    Ljungblad, Jonas; Hök, Bertil; Ekström, Mikael

    2016-01-01

    Breath alcohol screening is important for traffic safety, access control and other areas of health promotion. A family of sensor devices useful for these purposes is being developed and evaluated. This paper is focusing on algorithms for the determination of breath alcohol concentration in diluted breath samples using carbon dioxide to compensate for the dilution. The examined algorithms make use of signal averaging, weighting and personalization to reduce estimation errors. Evaluation has been performed by using data from a previously conducted human study. It is concluded that these features in combination will significantly reduce the random error compared to the signal averaging algorithm taken alone. PMID:27043576

  9. Aircraft fire safety research

    NASA Technical Reports Server (NTRS)

    Botteri, Benito P.

    1987-01-01

    During the past 15 years, very significant progress has been made toward enhancing aircraft fire safety in both normal and hostile (combat) operational environments. Most of the major aspects of the aircraft fire safety problem are touched upon here. The technology of aircraft fire protection, although not directly applicable in all cases to spacecraft fire scenarios, nevertheless does provide a solid foundation to build upon. This is particularly true of the extensive research and testing pertaining to aircraft interior fire safety and to onboard inert gas generation systems, both of which are still active areas of investigation.

  10. Safety shutdown separators

    DOEpatents

    Carlson, Steven Allen; Anakor, Ifenna Kingsley; Farrell, Greg Robert

    2015-06-30

    The present invention pertains to electrochemical cells which comprise (a) an anode; (b) a cathode; (c) a solid porous separator, such as a polyolefin, xerogel, or inorganic oxide separator; and (d) a nonaqueous electrolyte, wherein the separator comprises a porous membrane having a microporous coating comprising polymer particles which have not coalesced to form a continuous film. This microporous coating on the separator acts as a safety shutdown layer that rapidly increases the internal resistivity and shuts the cell down upon heating to an elevated temperature, such as 110.degree. C. Also provided are methods for increasing the safety of an electrochemical cell by utilizing such separators with a safety shutdown layer.

  11. Nuclear regulation and safety

    SciTech Connect

    Hendrie, J.M.

    1982-01-01

    Nuclear regulation and safety are discussed from the standpoint of a hypothetical country that is in the process of introducing a nuclear power industry and setting up a regulatory system. The national policy is assumed to be in favor of nuclear power. The regulators will have responsibility for economic, reliable electric production as well as for safety. Reactor safety is divided into three parts: shut it down, keep it covered, take out the afterheat. Emergency plans also have to be provided. Ways of keeping the core covered with water are discussed. (DLC)

  12. Aerostructural safety factor criteria

    NASA Technical Reports Server (NTRS)

    Verderaime, V.

    1992-01-01

    The present modification of the conventional safety factor method for aircraft structures evaluation involves the expression of deterministic safety factors in probabilistic tolerance limit ratios; these are found to involve a total of three factors that control the interference of applied and resistive stress distributions. The deterministic expression is extended so that it may furnish a 'relative ultimate safety' index that encompasses all three distribution factors. Operational reliability is developed on the basis of the applied and the yield stress distribution interferences. Industry standards are suggested to be derivable from factor selections that are based on the consequences of failure.

  13. Hierarchical Safety Cases

    NASA Technical Reports Server (NTRS)

    Denney, Ewen W.; Whiteside, Iain J.

    2012-01-01

    We introduce hierarchical safety cases (or hicases) as a technique to overcome some of the difficulties that arise creating and maintaining industrial-size safety cases. Our approach extends the existing Goal Structuring Notation with abstraction structures, which allow the safety case to be viewed at different levels of detail. We motivate hicases and give a mathematical account of them as well as an intuition, relating them to other related concepts. We give a second definition which corresponds closely to our implementation of hicases in the AdvoCATE Assurance Case Editor and prove the correspondence between the two. Finally, we suggest areas of future enhancement, both theoretically and practically.

  14. Safety Panel Resources

    NASA Technical Reports Server (NTRS)

    Stewart, Christine E.

    2008-01-01

    The goal of this paper is to explore what resources are potentially available to safety panels and to provide some guidance on how to utilize those resources. While the examples used in this paper will concentrate on the Flight Equipment and Reliability Review Panel (FESRRP) and Extravehicular Activity (EVA) hardware that have come through that panel, as well as resources at Johnson Space Center, the paper will address how this applies to safety panels in general, and where possible cite examples for other safety panels.

  15. Smoking and Home Fire Safety

    MedlinePlus

    ... training and education. More resources on smoking and fire safety Medical oxygen safety NFPA Educational Messages Desk Reference – these messages provide fire and life safety educators with accurate and consistent ...

  16. Nutritional Screening of Children: A Manual for Screening & Followup.

    ERIC Educational Resources Information Center

    Bureau of Community Health Services (DHHS/PHS), Rockville, MD.

    This manual shows health providers how to perform precisely and expertly each step of several procedures used in screening children for nutritional problems. It is intended for all health providers who are involved in weighing and measuring children, recording and plotting measurements on growth charts, taking blood samples to test for iron…

  17. [Lung cancer screening - risk stratification : Who should undergo screening?].

    PubMed

    Beer, L; Prosch, H

    2016-09-01

    Lung cancer is one of the leading causes of deaths in Europa and the USA. In approximately 75 % of lung cancer patients, bronchogenic carcinoma is detected at an advanced tumor stage; therefore, therapeutic options which aim at curing the disease in these patients are limited and treatment is mostly palliative. A relatively good prognosis is reserved for the minority of patients where the tumor is detected at an early stage and treatment is potentially curative. For this reason, early diagnosis of lung cancer could save lives. Retrospective analyses of the US national lung screening trial (NLST) showed that especially high-risk populations (e. g. higher age, positive smoking history, overweight and a positive family history for lung cancer) benefit most from lung cancer screening. Thus, the effectiveness of computed tomography (CT) screening can be improved by focusing on high-risk populations. This review article summarizes the risk stratification models of the large European and American screening studies and discusses possible future biomarkers for risk stratification. PMID:27495786

  18. Screening_mgmt: a Python module for managing screening data.

    PubMed

    Helfenstein, Andreas; Tammela, Päivi

    2015-02-01

    High-throughput screening is an established technique in drug discovery and, as such, has also found its way into academia. High-throughput screening generates a considerable amount of data, which is why specific software is used for its analysis and management. The commercially available software packages are often beyond the financial limits of small-scale academic laboratories and, furthermore, lack the flexibility to fulfill certain user-specific requirements. We have developed a Python module, screening_mgmt, which is a lightweight tool for flexible data retrieval, analysis, and storage for different screening assays in one central database. The module reads custom-made analysis scripts and plotting instructions, and it offers a graphical user interface to import, modify, and display the data in a uniform manner. During the test phase, we used this module for the management of 10,000 data points of various origins. It has provided a practical, user-friendly tool for sharing and exchanging information between researchers. PMID:25381290

  19. RNAi Screening in Spodoptera frugiperda.

    PubMed

    Ghosh, Subhanita; Singh, Gatikrushna; Sachdev, Bindiya; Kumar, Ajit; Malhotra, Pawan; Mukherjee, Sunil K; Bhatnagar, Raj K

    2016-01-01

    RNA interference is a potent and precise reverse genetic approach to carryout large-scale functional genomic studies in a given organism. During the past decade, RNAi has also emerged as an important investigative tool to understand the process of viral pathogenesis. Our laboratory has successfully generated transgenic reporter and RNAi sensor line of Spodoptera frugiperda (Sf21) cells and developed a reversal of silencing assay via siRNA or shRNA guided screening to investigate RNAi factors or viral pathogenic factors with extraordinary fidelity. Here we describe empirical approaches and conceptual understanding to execute successful RNAi screening in Spodoptera frugiperda 21-cell line. PMID:27581295

  20. Faraday screen sputtering on TPX

    SciTech Connect

    Ehst, D.A.

    1994-12-01

    The TPX design stipulates that the ion-cyclotron resonance frequency (ICRF) antenna must have a Faraday screen (FS). The author considers here possible low Z coatings for the screen, as well as sputtering behavior of the Ni and Ti substrates. The theory of rf-induced sputtering has been developed, and he follows those theoretical approaches. The author`s emphasis will be on both impurity generation as a possible source of increased Z{sub eff}, and also on actual erosion-lifetime of the materials under worst case conditions.

  1. Screening and Testing in Multiples.

    PubMed

    Evans, Mark I; Andriole, Stephanie; Evans, Shara M

    2016-06-01

    The choice of screening or invasive procedure in twin pregnancies is a personal choice of whether the patient wishes to take a small risk of having a baby with a serious disorder versus a small risk of having a complication because she wishes to avoid that. How to interpret such risks has profound effects on the perceived value of techniques, either leading to a decision to screening or going directly to chorionic villus sampling. There are profound issues surrounding the data and the interpretation of the data. No single short review can exhaustively examine all of the issues. PMID:27235913

  2. Breast Cancer Screening and Prevention.

    PubMed

    Nattinger, Ann B; Mitchell, Julie L

    2016-06-01

    This issue provides a clinical overview of breast cancer screening and prevention, focusing on risk assessment, screening, prevention, and practice improvement. The content of In the Clinic is drawn from the clinical information and education resources of the American College of Physicians (ACP), including MKSAP (Medical Knowledge and Self-Assessment Program). Annals of Internal Medicine editors develop In the Clinic in collaboration with the ACP's Medical Education and Publishing divisions and with the assistance of additional science writers and physician writers. PMID:27270661

  3. Tumor screening in Beckwith-Wiedemann syndrome-To screen or not to screen?

    PubMed

    Kalish, Jennifer M; Deardorff, Matthew A

    2016-09-01

    Beckwith-Wiedemann syndrome (BWS) is the most common imprinting disorder and consequently, one of the most common cancer predisposition disorders. Over the past 20 years, our understanding of the genetics and epigenetics leading to BWS has evolved and genotype/phenotype correlations have become readily apparent. Clinical management of these patients is focused on omphaloceles, hypoglycemia, macroglossia, hemihypertrophy, and tumor screening. Until recently, the need for tumor screening has been thought to be largely uniform across all genetic and epigenetic causes of BWS. As tumor risk correlates with genetic and epigenetic causes of BWS, several groups have proposed alterations to tumor screening protocols based on the etiology of BWS. However, there are many challenges inherent in adapting screening protocols. Such protocols must accommodate not only the risk based on genetic and epigenetic causes but also the medical cost-benefit of screening, the psychological impact on families, and the social-legal implications of missing a treatable tumor. © 2016 Wiley Periodicals, Inc. PMID:27518916

  4. Relationship of safety culture and process safety.

    PubMed

    Olive, Claire; O'Connor, T Michael; Mannan, M Sam

    2006-03-17

    Throughout history, humans have gathered in groups for social, religious, and industrial purposes. As the conglomeration of people interact, a set of underlying values, beliefs, and principles begins to develop that serve to guide behavior within the group. These "guidelines" are commonly referred to as the group culture. Modern-day organizations, including corporations, have developed their own unique cultures derived from the diversity of the organizational interests and the background of the employees. Safety culture, a sub-set of organizational culture, has been a major focus in recent years. This is especially true in the chemical industry due to the series of preventable, safety-related disasters that occurred in the late seventies and eighties. Some of the most notable disasters, during this time period, occurred at Bhopal, Flixborough, and Seveso. However, current events, like the September 11th terrorist attacks and the disintegration of the Columbia shuttle, have caused an assessment of safety culture in a variety of other organizations. PMID:16314040

  5. The safety at home study: an evidence base for policy and practice change.

    PubMed

    Doran, Diane; Blais, Régis; Baker, G Ross; Harrison, Margaret B; Lang, Ariella; Macdonald, Marilyn; McShane, Julie; Killackey, Tieghan

    2014-01-01

    This paper explores the policies and practices that are needed to improve the safety of home care in light of the most recent evidence about home care safety in Canada. Four areas for policy and practice change are addressed: 1) the promotion of effective communication processes in home care through cross-sector collaboration, case management and technology innovations; 2) screening for safety risk factors; 3) standardizing care processes, packaging and equipment; and 4) supporting family/caregivers and strengthening clients' ability to engage in therapeutic self-care. Evidence-based strategies for change are presented within the context of the evidence about home care safety issues. PMID:25591609

  6. Organizational Culture and Safety

    NASA Technical Reports Server (NTRS)

    Adams, Catherine A.

    2003-01-01

    '..only a fool perseveres in error.' Cicero. Humans will break the most advanced technological devices and override safety and security systems if they are given the latitude. Within the workplace, the operator may be just one of several factors in causing accidents or making risky decisions. Other variables considered for their involvement in the negative and often catastrophic outcomes include the organizational context and culture. Many organizations have constructed and implemented safety programs to be assimilated into their culture to assure employee commitment and understanding of the importance of everyday safety. The purpose of this paper is to examine literature on organizational safety cultures and programs that attempt to combat vulnerability, risk taking behavior and decisions and identify the role of training in attempting to mitigate unsafe acts.

  7. Aerospace Safety Advisory Panel

    NASA Technical Reports Server (NTRS)

    1993-01-01

    The Aerospace Safety Advisory Panel (ASAP) provided oversight on the safety aspects of many NASA programs. In addition, ASAP undertook three special studies. At the request of the Administrator, the panel assessed the requirements for an assured crew return vehicle (ACRV) for the space station and reviewed the organization of the safety and mission quality function within NASA. At the behest of Congress, the panel formed an independent, ad hoc working group to examine the safety and reliability of the space shuttle main engine. Section 2 presents findings and recommendations. Section 3 consists of information in support of these findings and recommendations. Appendices A, B, C, and D, respectively, cover the panel membership, the NASA response to the findings and recommendations in the March 1992 report, a chronology of the panel's activities during the reporting period, and the entire ACRV study report.

  8. Aerospace Safety Advisory Panel

    NASA Technical Reports Server (NTRS)

    1984-01-01

    An assessment of NASA's safety performance for 1983 affirms that NASA Headquarters and Center management teams continue to hold the safety of manned flight to be their prime concern, and that essential effort and resources are allocated for maintaining safety in all of the development and operational programs. Those conclusions most worthy of NASA management concentration are given along with recommendations for action concerning; product quality and utility; space shuttle main engine; landing gear; logistics and management; orbiter structural loads, landing speed, and pitch control; the shuttle processing contractor; and the safety of flight operations. It appears that much needs to be done before the Space Transportation System can achieve the reliability necessary for safe, high rate, low cost operations.

  9. Nanosensors for food safety.

    PubMed

    Li, Zhixiong; Sheng, Chenxing

    2014-01-01

    This review summarizes recent research and development of nanosensors applied to the food safety. Since the food safety is directly related to the people's health and life, the food detection has received considerable attentions. However, this food security has emerged in China as a severe problem in recent years. Food safety problems frequently compromised due to formaldehyde, poison vegetables, excessive pesticide residues, etc. These kinds of food contaminations could not be detected efficiently by traditional methods. Applying nanotechnology and nanominerals, various food contaminations can be identified accurately. Therefore nanosensors have been widely used in the food detection. We introduce current research on nanosensors followed by the industrial application of nanosensors. Finally, the challenges for the future food safety using nanosensors are discussed. PMID:24730307

  10. CHEMICAL SAFETY ALERTS-

    EPA Science Inventory

    Chemical Safety Alerts are short publications which explain specific hazards that have become evident through chemical accident investigation efforts. EPA has produced over a dozen Alerts to date. This year's Alert: Managing Chemical Reactivity Hazards

  11. Farm Safety (For Parents)

    MedlinePlus

    ... wheels or blind spots. Because adults who are operating machinery may be unable to see or hear ... a tractor and farm vehicle safety course before operating farm vehicles. Finally, teach older kids how to ...

  12. Medical Oxygen Safety

    MedlinePlus

    ... near the oxygen. Post No Smoking and No Open Flames signs in and outside the home to remind people not to smoke. Your Source for SAFETY Information NFPA Public Education Division • 1 Batterymarch Park, Quincy, MA 02169 Name ...

  13. NASA's Software Safety Standard

    NASA Technical Reports Server (NTRS)

    Ramsay, Christopher M.

    2007-01-01

    NASA relies more and more on software to control, monitor, and verify its safety critical systems, facilities and operations. Since the 1960's there has hardly been a spacecraft launched that does not have a computer on board that will provide command and control services. There have been recent incidents where software has played a role in high-profile mission failures and hazardous incidents. For example, the Mars Orbiter, Mars Polar Lander, the DART (Demonstration of Autonomous Rendezvous Technology), and MER (Mars Exploration Rover) Spirit anomalies were all caused or contributed to by software. The Mission Control Centers for the Shuttle, ISS, and unmanned programs are highly dependant on software for data displays, analysis, and mission planning. Despite this growing dependence on software control and monitoring, there has been little to no consistent application of software safety practices and methodology to NASA's projects with safety critical software. Meanwhile, academia and private industry have been stepping forward with procedures and standards for safety critical systems and software, for example Dr. Nancy Leveson's book Safeware: System Safety and Computers. The NASA Software Safety Standard, originally published in 1997, was widely ignored due to its complexity and poor organization. It also focused on concepts rather than definite procedural requirements organized around a software project lifecycle. Led by NASA Headquarters Office of Safety and Mission Assurance, the NASA Software Safety Standard has recently undergone a significant update. This new standard provides the procedures and guidelines for evaluating a project for safety criticality and then lays out the minimum project lifecycle requirements to assure the software is created, operated, and maintained in the safest possible manner. This update of the standard clearly delineates the minimum set of software safety requirements for a project without detailing the implementation for those

  14. Archetypes for Organisational Safety

    NASA Technical Reports Server (NTRS)

    Marais, Karen; Leveson, Nancy G.

    2003-01-01

    We propose a framework using system dynamics to model the dynamic behavior of organizations in accident analysis. Most current accident analysis techniques are event-based and do not adequately capture the dynamic complexity and non-linear interactions that characterize accidents in complex systems. In this paper we propose a set of system safety archetypes that model common safety culture flaws in organizations, i.e., the dynamic behaviour of organizations that often leads to accidents. As accident analysis and investigation tools, the archetypes can be used to develop dynamic models that describe the systemic and organizational factors contributing to the accident. The archetypes help clarify why safety-related decisions do not always result in the desired behavior, and how independent decisions in different parts of the organization can combine to impact safety.

  15. Safety at the Summit.

    ERIC Educational Resources Information Center

    Huddleston, Elizabeth

    2001-01-01

    Explores how risk-management strategies can make the difference in climbing wall safety. Wall design, adhering to wall construction standards, limiting wall access, and climber evaluation are discussed. (GR)

  16. Updated Lightning Safety Recommendations.

    ERIC Educational Resources Information Center

    Vavrek, R. James; Holle, Ronald L.; Lopez, Raul E.

    1999-01-01

    Summarizes the recommendations of the Lightning Safety Group (LSG), which was first convened during the 1998 American Meteorological Society Conference. Findings outline appropriate actions under various circumstances when lightning threatens. (WRM)

  17. Focusing on dam safety

    SciTech Connect

    Lagassa, G.

    1993-01-01

    With increased relicensing activity and a federal emphasis on safety, dam repair and refurbishment is a growing business. Providers of goods and services are gearing up to meet the dam repair and rehabilitation needs that result.

  18. The Hermes safety strategy

    NASA Astrophysics Data System (ADS)

    Rosso, R.

    The Hermes space vehicle currently in project for the European Space Agency will open the road to European autonomous manned space missions at the beginning of the 21st century. The safety objectives are very ambitious and will require the implementation of a comprehensive safety assurance program, aimed at reducing the risks to an acceptable level. The risk acceptance is based on identification, ranking and minimization of Critical Items including all potential departures from the safety requirements. Prime contractors shall prepare a Critical Item List for their elements, and submit it to the Hermes Program Directorate for review; approval of the residual open critical items shall be obtained before launch. An independent committee (HESAC) has been set up by the ESA and the French National Space Center (CNES) Directors General to assess the adequacy of the Safety Control Program.

  19. Shots for Safety

    MedlinePlus

    ... and Aging Shots For Safety Flu Pneumococcal Disease Tetanus and Diphtheria Shingles Measles, Mumps, and Rubella Side ... may need a second one to stay protected. Tetanus and Diphtheria Tetanus (sometimes called lockjaw) is caused ...

  20. Chemistry Laboratory Safety Check

    ERIC Educational Resources Information Center

    Patnoe, Richard L.

    1976-01-01

    An accident prevention/safety check list for chemistry laboratories is printed. Included are checks of equipment, facilities, storage and handling of chemicals, laboratory procedures, instruction procedures, and items to be excluded from chemical laboratories. (SL)

  1. Wildland Fire Safety

    MedlinePlus

    Wildland Fire Safety Every year, wildfires burn across the U.S., and more and more people are living where wildfires ... including garages and sheds. If it can catch fire, don’t let it touch your house, deck ...

  2. Religious Candles Safety

    MedlinePlus

    ... windows where a blind or curtain could catch fire. KKK Candles placed on, or near tables, altars, ... in a deep basin filled with water. General Fire Safety • Matches and lighters should be stored out ...

  3. CRITICALITY SAFETY POSTING GUIDELINES

    SciTech Connect

    JENSEN, M.A.

    2001-11-01

    This document provides a set of guidelines in the preparation of criticality safety postings. Guidance is provided in word choice, word arrangement, common human factors considerations. and use of color to highlight limits, cautions, and permissives.

  4. Bathroom safety - children

    MedlinePlus

    ... this page: //medlineplus.gov/ency/patientinstructions/000154.htm Bathroom safety - children To use the sharing features on ... please enable JavaScript. To prevent accidents in the bathroom, never leave your child alone in the bathroom. ...

  5. Vaccine Safety Datalink

    Cancer.gov

    The Vaccine Safety Datalink is part of the National Immunization Program within the Centers for Disease Control and Prevention and was started in recognition of gaps in the scientific knowledge of rare vaccine side effects.

  6. Chemical Safety Programs.

    ERIC Educational Resources Information Center

    Shaw, Richard

    2000-01-01

    Discusses the need to enhance understanding of chemical safety in educational facilities that includes adequate staff training and drilling requirements. The question of what is considered proper training is addressed. (GR)

  7. Governors Highway Safety Association

    MedlinePlus

    ... occupant protection, impaired driving, and speeding. GHSA provides leadership and advocacy for the states and territories to improve traffic safety , influence national policy , enhance program management and promote best practices . What's New National Highway ...

  8. Water Safety Quiz

    MedlinePlus

    ... Drive About Donating Blood Host a Blood Drive Training & Certification Find Classes First Aid CPR AED BLS Babysitting & Child Care Swimming Lifeguarding & Water Safety EMT CNA Train My Employees ...

  9. Smoking cessation and lung cancer screening

    PubMed Central

    Pedersen, Jesper Holst; Tønnesen, Philip

    2016-01-01

    Smoking behavior may have a substantial influence on the overall effect of lung cancer screening. Non-randomized studies of smoking behavior during screening have indicated that computer tomography (CT) screening induces smoking cessation. Randomized studies have further elaborated that this effect has to do with participation in screening alone and not dependent on the CT scan. Participants in both CT and control arm in randomized screening trials had higher smoking abstinence rate compared to that of the general population. A positive screening test seems to further promote smoking cessation and decrease smoking relapse rate. Also low smoking dependency and high motivation to quit smoking at baseline predicted smoking abstinence in screening trials. Lung cancer screening therefore seems to be a teachable moment for smoking cessation. Targeted smoking cessation counselling should be an integrated part of future lung cancer screening trials. PMID:27195275

  10. Screening methods for chemical warfare agents in environmental samples at the Edgewood area of Aberdeen Proving Ground, Maryland

    SciTech Connect

    Jakubowski, E.M.; Borland, M.M.; Norris, L.; Lattin, F.G.; Wrobel, J.

    1995-06-01

    The U.S. Army Edgewood Research, Development and Engineering Center, the U.S. Army Aberdeen Proving Ground Support Activity, Directorate of Safety, Health and the Environment and SciTech Services Inc., an independent contractor, have developed an approach for screening environmental samples for the presence of chemical warfare agents. Since 1918, the Edgewood area of Aberdeen Proving Ground has been a research and testing ground for toxic agent compounds. Since these materials are considered highly toxic, screening for their presence in environmental samples is necessary for safe shipment to contract laboratories for testing by EPA guidelines. The screening ensures worker safety and maintains U.S. Army standards for transportation of materials potentially contaminated with chemical warfare agents. This paper describes the screening methodology.

  11. Software system safety

    NASA Technical Reports Server (NTRS)

    Uber, James G.

    1988-01-01

    Software itself is not hazardous, but since software and hardware share common interfaces there is an opportunity for software to create hazards. Further, these software systems are complex, and proven methods for the design, analysis, and measurement of software safety are not yet available. Some past software failures, future NASA software trends, software engineering methods, and tools and techniques for various software safety analyses are reviewed. Recommendations to NASA are made based on this review.

  12. Bear Spray Safety Program

    USGS Publications Warehouse

    Blome, C.D.; Kuzniar, R.L.

    2009-01-01

    A bear spray safety program for the U.S. Geological Survey (USGS) was officially initiated by the Firearms Safety Committee to address accident prevention and to promote personnel training in bear spray and its transportation, storage, and use for defense against wild animals. Used as part of a system including firearms, or used alone for those who choose not to carry a firearm, bear spray is recognized as an effective tool that can prevent injury in a wild animal attack.

  13. Criticality safety training

    SciTech Connect

    Woodruff, S.K.

    1997-06-01

    Criticality safety training is an important element of the Plutonium Facility safety program at Los Alamos National Laboratory. Training consists of student self-study handbooks and hands-on performance-based training in a mock-up laboratory containing gloveboxes, trolley conveyor system, and self-monitoring instruments. A 10-minute video tape and lecture was presented to describe how training in this area is conducted.

  14. [Patient safety: Glossary].

    PubMed

    Sabio Paz, Verónica; Panattieri, Néstor D; Cristina Godio, Farmacéutica; Ratto, María E; Arpí, Lucrecia; Dackiewicz, Nora

    2015-10-01

    Patient safety and quality of care has become a challenge for health systems. Health care is an increasingly complex and risky activity, as it represents a combination of human, technological and organizational processes. It is necessary, therefore, to take effective actions to reduce the adverse events and mitigate its impact. This glossary is a local adaptation of key terms and concepts from the international bibliographic sources. The aim is providing a common language for assessing patient safety processes and compare them. PMID:26294153

  15. Aerospace safety advisory panel

    NASA Technical Reports Server (NTRS)

    1994-01-01

    This report from the Aerospace Safety Advisory Panel (ASAP) contains findings, recommendations, and supporting material concerning safety issues with the space station program, the space shuttle program, aeronautics research, and other NASA programs. Section two presents findings and recommendations, section three presents supporting information, and appendices contain data about the panel membership, the NASA response to the March 1993 ASAP report, and a chronology of the panel's activities during the past year.

  16. Autonomous Flight Safety System

    NASA Technical Reports Server (NTRS)

    Simpson, James

    2010-01-01

    The Autonomous Flight Safety System (AFSS) is an independent self-contained subsystem mounted onboard a launch vehicle. AFSS has been developed by and is owned by the US Government. Autonomously makes flight termination/destruct decisions using configurable software-based rules implemented on redundant flight processors using data from redundant GPS/IMU navigation sensors. AFSS implements rules determined by the appropriate Range Safety officials.

  17. Safety Auditing and Assessments

    NASA Technical Reports Server (NTRS)

    Goodin, James Ronald (Ronnie)

    2005-01-01

    Safety professionals typically do not engage in audits and independent assessments with the vigor as do our quality brethren. Taking advantage of industry and government experience conducting value added Independent Assessments or Audits benefits a safety program. Most other organizations simply call this process "internal audits." Sources of audit training are presented and compared. A relation of logic between audit techniques and mishap investigation is discussed. An example of an audit process is offered. Shortcomings and pitfalls of auditing are covered.

  18. The procedure safety system

    NASA Technical Reports Server (NTRS)

    Obrien, Maureen E.

    1990-01-01

    Telerobotic operations, whether under autonomous or teleoperated control, require a much more sophisticated safety system than that needed for most industrial applications. Industrial robots generally perform very repetitive tasks in a controlled, static environment. The safety system in that case can be as simple as shutting down the robot if a human enters the work area, or even simply building a cage around the work space. Telerobotic operations, however, will take place in a dynamic, sometimes unpredictable environment, and will involve complicated and perhaps unrehearsed manipulations. This creates a much greater potential for damage to the robot or objects in its vicinity. The Procedural Safety System (PSS) collects data from external sensors and the robot, then processes it through an expert system shell to determine whether an unsafe condition or potential unsafe condition exists. Unsafe conditions could include exceeding velocity, acceleration, torque, or joint limits, imminent collision, exceeding temperature limits, and robot or sensor component failure. If a threat to safety exists, the operator is warned. If the threat is serious enough, the robot is halted. The PSS, therefore, uses expert system technology to enhance safety thus reducing operator work load, allowing him/her to focus on performing the task at hand without the distraction of worrying about violating safety criteria.

  19. Safety Basis Report

    SciTech Connect

    R.J. Garrett

    2002-01-14

    As part of the internal Integrated Safety Management Assessment verification process, it was determined that there was a lack of documentation that summarizes the safety basis of the current Yucca Mountain Project (YMP) site characterization activities. It was noted that a safety basis would make it possible to establish a technically justifiable graded approach to the implementation of the requirements identified in the Standards/Requirements Identification Document. The Standards/Requirements Identification Documents commit a facility to compliance with specific requirements and, together with the hazard baseline documentation, provide a technical basis for ensuring that the public and workers are protected. This Safety Basis Report has been developed to establish and document the safety basis of the current site characterization activities, establish and document the hazard baseline, and provide the technical basis for identifying structures, systems, and components (SSCs) that perform functions necessary to protect the public, the worker, and the environment from hazards unique to the YMP site characterization activities. This technical basis for identifying SSCs serves as a grading process for the implementation of programs such as Conduct of Operations (DOE Order 5480.19) and the Suspect/Counterfeit Items Program. In addition, this report provides a consolidated summary of the hazards analyses processes developed to support the design, construction, and operation of the YMP site characterization facilities and, therefore, provides a tool for evaluating the safety impacts of changes to the design and operation of the YMP site characterization activities.

  20. Safety system status monitoring

    SciTech Connect

    Lewis, J.R.; Morgenstern, M.H.; Rideout, T.H.; Cowley, P.J.

    1984-03-01

    The Pacific Northwest Laboratory has studied the safety aspects of monitoring the preoperational status of safety systems in nuclear power plants. The goals of the study were to assess for the NRC the effectiveness of current monitoring systems and procedures, to develop near-term guidelines for reducing human errors associated with monitoring safety system status, and to recommend a regulatory position on this issue. A review of safety system status monitoring practices indicated that current systems and procedures do not adequately aid control room operators in monitoring safety system status. This is true even of some systems and procedures installed to meet existing regulatory guidelines (Regulatory Guide 1.47). In consequence, this report suggests acceptance criteria for meeting the functional requirements of an adequate system for monitoring safety system status. Also suggested are near-term guidelines that could reduce the likelihood of human errors in specific, high-priority status monitoring tasks. It is recommended that (1) Regulatory Guide 1.47 be revised to address these acceptance criteria, and (2) the revised Regulatory Guide 1.47 be applied to all plants, including those built since the issuance of the original Regulatory Guide.

  1. Autonomous Flight Safety System

    NASA Technical Reports Server (NTRS)

    Ferrell, Bob; Santuro, Steve; Simpson, James; Zoerner, Roger; Bull, Barton; Lanzi, Jim

    2004-01-01

    Autonomous Flight Safety System (AFSS) is an independent flight safety system designed for small to medium sized expendable launch vehicles launching from or needing range safety protection while overlying relatively remote locations. AFSS replaces the need for a man-in-the-loop to make decisions for flight termination. AFSS could also serve as the prototype for an autonomous manned flight crew escape advisory system. AFSS utilizes onboard sensors and processors to emulate the human decision-making process using rule-based software logic and can dramatically reduce safety response time during critical launch phases. The Range Safety flight path nominal trajectory, its deviation allowances, limit zones and other flight safety rules are stored in the onboard computers. Position, velocity and attitude data obtained from onboard global positioning system (GPS) and inertial navigation system (INS) sensors are compared with these rules to determine the appropriate action to ensure that people and property are not jeopardized. The final system will be fully redundant and independent with multiple processors, sensors, and dead man switches to prevent inadvertent flight termination. AFSS is currently in Phase III which includes updated algorithms, integrated GPS/INS sensors, large scale simulation testing and initial aircraft flight testing.

  2. Screening Tests for Birth Defects

    MedlinePlus

    Member Login Join Pay Dues Follow us: Women's Health Care Physicians Contact Us My ACOG ACOG Departments Donate Shop Career Connection Home Resources & Publications Practice Management Education & Events Advocacy For Patients About ACOG Screening Tests for Birth Defects Home For Patients Search FAQs ...

  3. First Grade Pre-Screening

    ERIC Educational Resources Information Center

    Center for Innovation in Assessment (NJ1), 2013

    2013-01-01

    The First Grade Pre-Screening is designed to be used at the start of the first grade school year so that teachers can obtain information about their incoming students. This information is intended to give teachers insight about what math and reading skills a student may or may not have at the beginning of the year. The information can aid teachers…

  4. Pilot Programs in Newborn Screening

    ERIC Educational Resources Information Center

    Pass, Kenneth; Green, Nancy S.; Lorey, Fred; Sherwin, John; Comeau, Anne Marie

    2006-01-01

    The term "pilot study" has been used over the years to describe the evaluation of the many elements involved in deciding whether a proposed condition should be added to a newborn screening (NBS) panel, and until recently, was unilaterally used to describe the evaluation of the assay to be used before the condition was officially adopted by a state…

  5. Newborn Screening for Biliary Atresia

    PubMed Central

    Wang, Kasper S.

    2016-01-01

    Biliary atresia is the most common cause of pediatric end-stage liver disease and the leading indication for pediatric liver transplantation. Affected infants exhibit evidence of biliary obstruction within the first few weeks after birth. Early diagnosis and successful surgical drainage of bile are associated with greater survival with the child’s native liver. Unfortunately, because noncholestatic jaundice is extremely common in early infancy, it is difficult to identify the rare infant with cholestatic jaundice who has biliary atresia. Hence, the need for timely diagnosis of this disease warrants a discussion of the feasibility of screening for biliary atresia to improve outcomes. Herein, newborn screening for biliary atresia in the United States is assessed by using criteria established by the Discretionary Advisory Committee on Heritable Disorders in Newborns and Children. Published analyses indicate that newborn screening for biliary atresia by using serum bilirubin concentrations or stool color cards is potentially life-saving and cost-effective. Further studies are necessary to evaluate the feasibility, effectiveness, and costs of potential screening strategies for early identification of biliary atresia in the United States. PMID:26620065

  6. Improving Efficiency in Articulation Screening.

    ERIC Educational Resources Information Center

    Eveleigh, Katharine F.; Warr-Leeper, Genese A.

    1983-01-01

    The screening version of the Photo Articulation Test elicited significantly more correct initial picture identifications than either the Fisher-Logemann Test of Articulation Competence or the Templin-Darley Test of Articulation. Significant relationships between diagnostic decision and clinical judgments were obtained for both normal and…

  7. 75 FR 3182 - Intake Screening

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-20

    ...; ] DEPARTMENT OF JUSTICE Bureau of Prisons 28 CFR Part 522 RIN 1120-AB47 Intake Screening AGENCY: Bureau of Prisons, Justice. ACTION: Proposed rule. SUMMARY: In this document, the Bureau of Prisons (Bureau... to the Rules Unit, Office of General Counsel, Bureau of Prisons, 320 First Street, NW.,...

  8. Screening Applicants for Teacher Training

    ERIC Educational Resources Information Center

    Draba, Robert E.; Steinkellner, Lesley Linde

    1977-01-01

    The identification of criteria and procedures to be used for selecting applicants for teacher training is a problem that has received considerable comment and inquiry. Evaluates one selection criterion, the preservice teacher's ability to read, as an aid in the screening process. (Author/RK)

  9. Native Language Literacy Screening Device.

    ERIC Educational Resources Information Center

    Hudson River Center for Program Development, Glenmont, NY.

    The purpose the Native Language Literacy Screening Device (NLLSD) is to give English for Speakers of Other Languages (ESOL) practitioners a sense of the native language literacy levels of learners coming into their programs. This is worth knowing because when learners have had limited schooling in their first language instructional strategies used…

  10. [Screening in open angle glaucoma].

    PubMed

    Mocanu, Carmen; Mocanu, Andrei

    2012-01-01

    Primary open angle glaucoma (POAG) represents the second cause of mondial cecity, after retinal diabetes complications, with extremely severe implications in quality of life. Screening testing for glaucoma is justified, because only the diagnosis in very incipient stage will preserve the visual function; any treatment will not assure the reversibility of pre-existent optic nerve lesions. Screening of glaucoma, will take into a consideration the costs, the time of investigation, the adverse effects, and the sensitivity and specificity of tests; the last parameter also will strongly influence the positive predictive value. An ideal screening identifies all subjects that present the disease (sensitivity) and will exclude all healthy subjects (specificity). In this moment, in Dolj district, the diagnosis is based on active diagnosis of new cases of glaucoma on the high risk level population, therefore in a 210000 habitants. 4723 patients with glaucoma are diagnosed, screened and follow-up on medical cabinets and on Center of Glaucoma, which coordinates their activity. To better monitored patients, automatized programs with acquisition and storage for different types of medical imaging facilities had become indispensable to any routine practice. PMID:23755511

  11. MedlinePlus: Newborn Screening

    MedlinePlus

    ... Phenylketonuria National Institutes of Health The primary NIH organization for research on Newborn Screening is the National Institute of Child Health and Human Development Languages Arabic (العربية) Bosnian (Bosanski) Chinese - Simplified (简体中文) ...

  12. TOXICITY SCREENING WITH ZEBRAFISH ASSAY

    EPA Science Inventory

    The proposed toxicity screening will help EPA to prioritize chemicals for further testing, and it may also alert chemical manufacturers that some of their commercial products may be toxic. The proposed toxicity pathway studies will improve the research community’s abi...

  13. Tomosynthesis for breast cancer screening.

    PubMed

    Cole, Elodia B; Pisano, Etta D

    2016-01-01

    Breast tomosynthesis, a three-dimensional x-ray based breast imaging technology, has been available for clinical use in the United States since 2011. In this paper we review the literature on breast cancer screening with this new technology including where gaps in knowledge remain. PMID:26472036

  14. A consensus statement for safety monitoring guidelines of treatments for major depressive disorder

    PubMed Central

    Dodd, Seetal; Malhi, Gin S; Tiller, John; Schweitzer, Isaac; Hickie, Ian; Khoo, Jon Paul; Bassett, Darryl L; Lyndon, Bill; Mitchell, Philip B; Parker, Gordon; Fitzgerald, Paul B; Udina, Marc; Singh, Ajeet; Moylan, Steven; Giorlando, Francesco; Doughty, Carolyn; Davey, Christopher G; Theodoras, Michael; Berk, Michael

    2011-01-01

    Objective This paper aims to present an overview of screening and safety considerations for the treatment of clinical depressive disorders and make recommendations for safety monitoring. Method Data were sourced by a literature search using MEDLINE and a manual search of scientific journals to identify relevant articles. Draft guidelines were prepared and serially revised in an iterative manner until all co-authors gave final approval of content. Results Screening and monitoring can detect medical causes of depression. Specific adverse effects associated with antidepressant treatments may be reduced or identified earlier by baseline screening and agent-specific monitoring after commencing treatment. Conclusion The adoption of safety monitoring guidelines when treating clinical depression is likely to improve overall physical health status and treatment outcome. It is important to implement these guidelines in the routine management of clinical depression. PMID:21888608

  15. Agricultural safety efforts by county health departments in Wisconsin.

    PubMed Central

    Chapman, L J; Schuler, R T; Wilkinson, T L; Skjolaas, C A

    1996-01-01

    OBJECTIVE: The authors sought to improve the agriculture safety prevention efforts of county health departments in Wisconsin by examining current programs, staffs' perceptions of the farm safety problem, and the need for new resources. METHODS: A survey instrument was completed by a professional staff member of the local health department in each of Wisconsin's 69 counties. RESULTS: Usable responses were obtained from 84% of the counties. Forty-five percent of the responding staff members conducted some agricultural safety and health programs, most often health screenings or group meetings conducted collaboratively with county agricultural Extension agents. There were no major differences in county demographics or other service provision variables between staff members who conducted programs and those who did not. Staff members perceived the largest barriers to better safety as lack of staff time and difficulty getting farmers to attend safety programs. Most failed to place more emphasis on training agricultural workers to permanently correct hazards than on training them to work safely around hazards. However, the staff members ranked safety inspection checklists as the most needed new material and ranked Extension agents and farmers as the most appropriate people to conduct inspections using such checklists. CONCLUSION: County public health professionals want more staff time and new materials to increase the effectiveness of their agricultural safety efforts. Encouraging agricultural workers and family members to identify and correct hazards would be a more effective use of staff time than training people to work safely around hazards. PMID:8837633

  16. Colorectal Cancer Screening in Vietnamese Americans

    PubMed Central

    Nguyen, Bang H.

    2008-01-01

    Background Rates of colorectal cancer screening in Vietnamese Americans are lower than those in non-Hispanic whites. This paper describes rates of colorectal screening, identifies determinants, and recommends educational strategies to improve screening. Methods A cross-sectional sample of 867 Vietnamese aged 50 to 74 drawn from a sampling frame of individuals in the Alameda and Santa Clara Counties, California and Harris County, Texas area telephone directories with Vietnamese surnames were interviewed in 2004. Results Colorectal screening recognition, receipt, currency, and intention rates were low. Conclusions: While the screening rates are low, Vietnamese are receptive to screening if providers recommend it. PMID:18444045

  17. Screening systems adapt to changing conditions

    SciTech Connect

    Fiscor, S.

    2009-08-15

    Prep plants are installing larger screening systems and synthetic media is meeting those challenges. The largest manufacturer of synthetic screen media is Polydeck located in Spartanburg, South Carolina. The company's primary product lines include modular polyurethane and rubber screen panels and the frame systems to support the media. The modular approach overcomes a wear problem in one area of the deck common on Banana screens and facilitates maintenance. A rubber formation used in 1- x 2-pt screen panels called the Flexi design is softer and allows more vibration than standard urethane panels. The Maxi screen panel design combined with the PipeTop II frame makes the system highly versatile. 1 photo.

  18. Chemical compatibility screening test results

    SciTech Connect

    Nigrey, P.J.; Dickens, T.G.

    1997-12-01

    A program for evaluating packaging components that may be used in transporting mixed-waste forms has been developed and the first phase has been completed. This effort involved the screening of ten plastic materials in four simulant mixed-waste types. These plastics were butadiene-acrylonitrile copolymer rubber, cross-linked polyethylene (XLPE), epichlorohydrin rubber, ethylene-propylene rubber (EPDM), fluorocarbon (Viton or Kel-F), polytetrafluoroethylene, high-density polyethylene (HDPE), isobutylene-isoprene copolymer rubber (butyl), polypropylene, and styrene-butadiene rubber (SBR). The selected simulant mixed wastes were (1) an aqueous alkaline mixture of sodium nitrate and sodium nitrite; (2) a chlorinated hydrocarbon mixture; (3) a simulant liquid scintillation fluid; and (4) a mixture of ketones. The testing protocol involved exposing the respective materials to 286,000 rads of gamma radiation followed by 14-day exposures to the waste types at 60{degrees}C. The seal materials were tested using vapor transport rate (VTR) measurements while the liner materials were tested using specific gravity as a metric. For these tests, a screening criterion of 0.9 g/hr/m{sup 2} for VTR and a specific gravity change of 10% was used. Based on this work, it was concluded that while all seal materials passed exposure to the aqueous simulant mixed waste, EPDM and SBR had the lowest VTRs. In the chlorinated hydrocarbon simulant mixed waste, only Viton passed the screening tests. In both the simulant scintillation fluid mixed waste and the ketone mixture simulant mixed waste, none of the seal materials met the screening criteria. For specific gravity testing of liner materials, the data showed that while all materials with the exception of polypropylene passed the screening criteria, Kel-F, HDPE, and XLPE offered the greatest resistance to the combination of radiation and chemicals.

  19. Non-invasive prenatal testing for aneuploidy and beyond: challenges of responsible innovation in prenatal screening

    PubMed Central

    Dondorp, Wybo; de Wert, Guido; Bombard, Yvonne; Bianchi, Diana W; Bergmann, Carsten; Borry, Pascal; Chitty, Lyn S; Fellmann, Florence; Forzano, Francesca; Hall, Alison; Henneman, Lidewij; Howard, Heidi C; Lucassen, Anneke; Ormond, Kelly; Peterlin, Borut; Radojkovic, Dragica; Rogowski, Wolf; Soller, Maria; Tibben, Aad; Tranebjærg, Lisbeth; van El, Carla G; Cornel, Martina C

    2015-01-01

    This paper contains a joint ESHG/ASHG position document with recommendations regarding responsible innovation in prenatal screening with non-invasive prenatal testing (NIPT). By virtue of its greater accuracy and safety with respect to prenatal screening for common autosomal aneuploidies, NIPT has the potential of helping the practice better achieve its aim of facilitating autonomous reproductive choices, provided that balanced pretest information and non-directive counseling are available as part of the screening offer. Depending on the health-care setting, different scenarios for NIPT-based screening for common autosomal aneuploidies are possible. The trade-offs involved in these scenarios should be assessed in light of the aim of screening, the balance of benefits and burdens for pregnant women and their partners and considerations of cost-effectiveness and justice. With improving screening technologies and decreasing costs of sequencing and analysis, it will become possible in the near future to significantly expand the scope of prenatal screening beyond common autosomal aneuploidies. Commercial providers have already begun expanding their tests to include sex-chromosomal abnormalities and microdeletions. However, multiple false positives may undermine the main achievement of NIPT in the context of prenatal screening: the significant reduction of the invasive testing rate. This document argues for a cautious expansion of the scope of prenatal screening to serious congenital and childhood disorders, only following sound validation studies and a comprehensive evaluation of all relevant aspects. A further core message of this document is that in countries where prenatal screening is offered as a public health programme, governments and public health authorities should adopt an active role to ensure the responsible innovation of prenatal screening on the basis of ethical principles. Crucial elements are the quality of the screening process as a whole (including non

  20. Non-invasive prenatal testing for aneuploidy and beyond: challenges of responsible innovation in prenatal screening.

    PubMed

    Dondorp, Wybo; de Wert, Guido; Bombard, Yvonne; Bianchi, Diana W; Bergmann, Carsten; Borry, Pascal; Chitty, Lyn S; Fellmann, Florence; Forzano, Francesca; Hall, Alison; Henneman, Lidewij; Howard, Heidi C; Lucassen, Anneke; Ormond, Kelly; Peterlin, Borut; Radojkovic, Dragica; Rogowski, Wolf; Soller, Maria; Tibben, Aad; Tranebjærg, Lisbeth; van El, Carla G; Cornel, Martina C

    2015-11-01

    This paper contains a joint ESHG/ASHG position document with recommendations regarding responsible innovation in prenatal screening with non-invasive prenatal testing (NIPT). By virtue of its greater accuracy and safety with respect to prenatal screening for common autosomal aneuploidies, NIPT has the potential of helping the practice better achieve its aim of facilitating autonomous reproductive choices, provided that balanced pretest information and non-directive counseling are available as part of the screening offer. Depending on the health-care setting, different scenarios for NIPT-based screening for common autosomal aneuploidies are possible. The trade-offs involved in these scenarios should be assessed in light of the aim of screening, the balance of benefits and burdens for pregnant women and their partners and considerations of cost-effectiveness and justice. With improving screening technologies and decreasing costs of sequencing and analysis, it will become possible in the near future to significantly expand the scope of prenatal screening beyond common autosomal aneuploidies. Commercial providers have already begun expanding their tests to include sex-chromosomal abnormalities and microdeletions. However, multiple false positives may undermine the main achievement of NIPT in the context of prenatal screening: the significant reduction of the invasive testing rate. This document argues for a cautious expansion of the scope of prenatal screening to serious congenital and childhood disorders, only following sound validation studies and a comprehensive evaluation of all relevant aspects. A further core message of this document is that in countries where prenatal screening is offered as a public health programme, governments and public health authorities should adopt an active role to ensure the responsible innovation of prenatal screening on the basis of ethical principles. Crucial elements are the quality of the screening process as a whole (including non