Science.gov

Sample records for 4d thoracic ct

  1. Quantifying the impact of respiratory-gated 4D CT acquisition on thoracic image quality: A digital phantom study

    SciTech Connect

    Bernatowicz, K. Knopf, A.; Lomax, A.; Keall, P.; Kipritidis, J.; Mishra, P.

    2015-01-15

    Purpose: Prospective respiratory-gated 4D CT has been shown to reduce tumor image artifacts by up to 50% compared to conventional 4D CT. However, to date no studies have quantified the impact of gated 4D CT on normal lung tissue imaging, which is important in performing dose calculations based on accurate estimates of lung volume and structure. To determine the impact of gated 4D CT on thoracic image quality, the authors developed a novel simulation framework incorporating a realistic deformable digital phantom driven by patient tumor motion patterns. Based on this framework, the authors test the hypothesis that respiratory-gated 4D CT can significantly reduce lung imaging artifacts. Methods: Our simulation framework synchronizes the 4D extended cardiac torso (XCAT) phantom with tumor motion data in a quasi real-time fashion, allowing simulation of three 4D CT acquisition modes featuring different levels of respiratory feedback: (i) “conventional” 4D CT that uses a constant imaging and couch-shift frequency, (ii) “beam paused” 4D CT that interrupts imaging to avoid oversampling at a given couch position and respiratory phase, and (iii) “respiratory-gated” 4D CT that triggers acquisition only when the respiratory motion fulfills phase-specific displacement gating windows based on prescan breathing data. Our framework generates a set of ground truth comparators, representing the average XCAT anatomy during beam-on for each of ten respiratory phase bins. Based on this framework, the authors simulated conventional, beam-paused, and respiratory-gated 4D CT images using tumor motion patterns from seven lung cancer patients across 13 treatment fractions, with a simulated 5.5 cm{sup 3} spherical lesion. Normal lung tissue image quality was quantified by comparing simulated and ground truth images in terms of overall mean square error (MSE) intensity difference, threshold-based lung volume error, and fractional false positive/false negative rates. Results

  2. SU-E-J-241: Creation of Ventilation CT From Daily 4D CTs Or 4D Conebeam CTs Acquired During IGRT for Thoracic Cancers

    SciTech Connect

    Tai, A; Ahunbay, E; Li, X

    2014-06-01

    Purpose: To develop a method to create ventilation CTs from daily 4D CTs or 4D KV conebeam CTs (4DCBCT) acquired during image-guided radiation therapy (IGRT) for thoracic tumors, and to explore the potential for using the ventilation CTs as a means for early detection of lung injury during radiation treatment. Methods: 4DCT acquired using an in-room CT (CTVision, Siemens) and 4DCBCT acquired using the X-ray Volume Imaging (XVI) system (Infinity, Elekta) for representative lung cancer patients were analyzed. These 4D data sets were sorted into 10 phase images. A newly-available deformable image registration tool (ADMIRE, Elekta) is used to deform the phase images at the end of exhale (EE) to the phase images at the end of inhale (EI). The lung volumes at EI and EE were carefully contoured using an intensity-based auto-contour tool and then manually edited. The ventilation images were calculated from the variations of CT numbers of those voxels masked by the lung contour at EI between the registered phase images. The deformable image registration is also performed between the daily 4D images and planning 4DCT, and the resulting deformable field vector (DFV) is used to deform the planning doses to the daily images by an in-house Matlab program. Results: The ventilation images were successfully created. The tide volumes calculated using the ventilation images agree with those measured through volume difference of contours at EE and EI, indicating the accuracy of ventilation images. The association between the delivered doses and the change of lung ventilation from the daily ventilation CTs is identified. Conclusions: A method to create the ventilation CT using daily 4DCTs or 4D KV conebeam CTs was developed and demonstrated.

  3. IMRT treatment plans and functional planning with functional lung imaging from 4D-CT for thoracic cancer patients

    PubMed Central

    2013-01-01

    Background and purpose Currently, the inhomogeneity of the pulmonary function is not considered when treatment plans are generated in thoracic cancer radiotherapy. This study evaluates the dose of treatment plans on highly-functional volumes and performs functional treatment planning by incorporation of ventilation data from 4D-CT. Materials and methods Eleven patients were included in this retrospective study. Ventilation was calculated using 4D-CT. Two treatment plans were generated for each case, the first one without the incorporation of the ventilation and the second with it. The dose of the first plans was overlapped with the ventilation and analyzed. Highly-functional regions were avoided in the second treatment plans. Results For small targets in the first plans (PTV < 400 cc, 6 cases), all V5, V20 and the mean lung dose values for the highly-functional regions were lower than that of the total lung. For large targets, two out of five cases had higher V5 and V20 values for the highly-functional regions. All the second plans were within constraints. Conclusion Radiation treatments affect functional lung more seriously in large tumor cases. With compromise of dose to other critical organs, functional treatment planning to reduce dose in highly-functional lung volumes can be achieved PMID:23281734

  4. Beam-specific planning target volumes incorporating 4D CT for pencil beam scanning proton therapy of thoracic tumors.

    PubMed

    Lin, Liyong; Kang, Minglei; Huang, Sheng; Mayer, Rulon; Thomas, Andrew; Solberg, Timothy D; McDonough, James E; Simone, Charles B

    2015-11-08

    The purpose of this study is to determine whether organ sparing and target coverage can be simultaneously maintained for pencil beam scanning (PBS) proton therapy treatment of thoracic tumors in the presence of motion, stopping power uncertainties, and patient setup variations. Ten consecutive patients that were previously treated with proton therapy to 66.6/1.8 Gy (RBE) using double scattering (DS) were replanned with PBS. Minimum and maximum intensity images from 4D CT were used to introduce flexible smearing in the determination of the beam specific PTV (BSPTV). Datasets from eight 4D CT phases, using ± 3% uncertainty in stopping power and ± 3 mm uncertainty in patient setup in each direction, were used to create 8 × 12 × 10 = 960 PBS plans for the evaluation of 10 patients. Plans were normalized to provide identical coverage between DS and PBS. The average lung V20, V5, and mean doses were reduced from 29.0%, 35.0%, and 16.4 Gy with DS to 24.6%, 30.6%, and 14.1 Gy with PBS, respectively. The average heart V30 and V45 were reduced from 10.4% and 7.5% in DS to 8.1% and 5.4% for PBS, respectively. Furthermore, the maximum spinal cord, esophagus, and heart doses were decreased from 37.1 Gy, 71.7 Gy, and 69.2 Gy with DS to 31.3 Gy, 67.9 Gy, and 64.6 Gy with PBS. The conformity index (CI), homogeneity index (HI), and global maximal dose were improved from 3.2, 0.08, 77.4 Gy with DS to 2.8, 0.04, and 72.1 Gy with PBS. All differences are statistically significant, with p-values <0.05, with the exception of the heart V45 (p = 0.146). PBS with BSPTV achieves better organ sparing and improves target coverage using a repainting method for the treatment of thoracic tumors. Incorporating motion-related uncertainties is essential.

  5. Beam-specific planning target volumes incorporating 4D CT for pencil beam scanning proton therapy of thoracic tumors.

    PubMed

    Lin, Liyong; Kang, Minglei; Huang, Sheng; Mayer, Rulon; Thomas, Andrew; Solberg, Timothy D; McDonough, James E; Simone, Charles B

    2015-11-01

    The purpose of this study is to determine whether organ sparing and target coverage can be simultaneously maintained for pencil beam scanning (PBS) proton therapy treatment of thoracic tumors in the presence of motion, stopping power uncertainties, and patient setup variations. Ten consecutive patients that were previously treated with proton therapy to 66.6/1.8 Gy (RBE) using double scattering (DS) were replanned with PBS. Minimum and maximum intensity images from 4D CT were used to introduce flexible smearing in the determination of the beam specific PTV (BSPTV). Datasets from eight 4D CT phases, using ±3% uncertainty in stopping power and ±3 mm uncertainty in patient setup in each direction, were used to create 8×12×10=960 PBS plans for the evaluation of 10 patients. Plans were normalized to provide identical coverage between DS and PBS. The average lung V20, V5, and mean doses were reduced from 29.0%, 35.0%, and 16.4 Gy with DS to 24.6%, 30.6%, and 14.1 Gy with PBS, respectively. The average heart V30 and V45 were reduced from 10.4% and 7.5% in DS to 8.1% and 5.4% for PBS, respectively. Furthermore, the maximum spinal cord, esophagus, and heart doses were decreased from 37.1 Gy, 71.7 Gy, and 69.2 Gy with DS to 31.3 Gy, 67.9 Gy, and 64.6 Gy with PBS. The conformity index (CI), homogeneity index (HI), and global maximal dose were improved from 3.2, 0.08, 77.4 Gy with DS to 2.8, 0.04, and 72.1 Gy with PBS. All differences are statistically significant, with p-values <0.05, with the exception of the heart V45 (p=0.146). PBS with BSPTV achieves better organ sparing and improves target coverage using a repainting method for the treatment of thoracic tumors. Incorporating motion-related uncertainties is essential. PACS number: 87.55.D.

  6. Image quality in thoracic 4D cone-beam CT: A sensitivity analysis of respiratory signal, binning method, reconstruction algorithm, and projection angular spacing

    SciTech Connect

    Shieh, Chun-Chien; Kipritidis, John; O’Brien, Ricky T.; Keall, Paul J.; Kuncic, Zdenka

    2014-04-15

    Purpose: Respiratory signal, binning method, and reconstruction algorithm are three major controllable factors affecting image quality in thoracic 4D cone-beam CT (4D-CBCT), which is widely used in image guided radiotherapy (IGRT). Previous studies have investigated each of these factors individually, but no integrated sensitivity analysis has been performed. In addition, projection angular spacing is also a key factor in reconstruction, but how it affects image quality is not obvious. An investigation of the impacts of these four factors on image quality can help determine the most effective strategy in improving 4D-CBCT for IGRT. Methods: Fourteen 4D-CBCT patient projection datasets with various respiratory motion features were reconstructed with the following controllable factors: (i) respiratory signal (real-time position management, projection image intensity analysis, or fiducial marker tracking), (ii) binning method (phase, displacement, or equal-projection-density displacement binning), and (iii) reconstruction algorithm [Feldkamp–Davis–Kress (FDK), McKinnon–Bates (MKB), or adaptive-steepest-descent projection-onto-convex-sets (ASD-POCS)]. The image quality was quantified using signal-to-noise ratio (SNR), contrast-to-noise ratio, and edge-response width in order to assess noise/streaking and blur. The SNR values were also analyzed with respect to the maximum, mean, and root-mean-squared-error (RMSE) projection angular spacing to investigate how projection angular spacing affects image quality. Results: The choice of respiratory signals was found to have no significant impact on image quality. Displacement-based binning was found to be less prone to motion artifacts compared to phase binning in more than half of the cases, but was shown to suffer from large interbin image quality variation and large projection angular gaps. Both MKB and ASD-POCS resulted in noticeably improved image quality almost 100% of the time relative to FDK. In addition, SNR

  7. TU-G-BRA-04: Changes in Regional Lung Function Measured by 4D-CT Ventilation Imaging for Thoracic Radiotherapy

    SciTech Connect

    Nakajima, Y; Kadoya, N; Kabus, S; Loo, B; Keall, P; Yamamoto, T

    2015-06-15

    Purpose: To test the hypothesis: 4D-CT ventilation imaging can show the known effects of radiotherapy on lung function: (1) radiation-induced ventilation reductions, and (2) ventilation increases caused by tumor regression. Methods: Repeat 4D-CT scans (pre-, mid- and/or post-treatment) were acquired prospectively for 11 thoracic cancer patients in an IRB-approved clinical trial. A ventilation image for each time point was created using deformable image registration and the Hounsfield unit (HU)-based or Jacobian-based metric. The 11 patients were divided into two subgroups based on tumor volume reduction using a threshold of 5 cm{sup 3}. To quantify radiation-induced ventilation reduction, six patients who showed a small tumor volume reduction (<5 cm{sup 3}) were analyzed for dose-response relationships. To investigate ventilation increase caused by tumor regression, two of the other five patients were analyzed to compare ventilation changes in the lung lobes affected and unaffected by the tumor. The remaining three patients were excluded because there were no unaffected lobes. Results: Dose-dependent reductions of HU-based ventilation were observed in a majority of the patient-specific dose-response curves and in the population-based dose-response curve, whereas no clear relationship was seen for Jacobian-based ventilation. The post-treatment population-based dose-response curve of HU-based ventilation demonstrated the average ventilation reductions of 20.9±7.0% at 35–40 Gy (equivalent dose in 2-Gy fractions, EQD2), and 40.6±22.9% at 75–80 Gy EQD2. Remarkable ventilation increases in the affected lobes were observed for the two patients who showed an average tumor volume reduction of 37.1 cm{sup 3} and re-opening airways. The mid-treatment increase in HU-based ventilation of patient 3 was 100.4% in the affected lobes, which was considerably greater than 7.8% in the unaffected lobes. Conclusion: This study has demonstrated that 4D-CT ventilation imaging shows

  8. Thoracic textilomas: CT findings*

    PubMed Central

    Machado, Dianne Melo; Zanetti, Gláucia; Araujo, Cesar Augusto; Nobre, Luiz Felipe; Meirelles, Gustavo de Souza Portes; Pereira e Silva, Jorge Luiz; Guimarães, Marcos Duarte; Escuissato, Dante Luiz; Souza, Arthur Soares; Hochhegger, Bruno; Marchiori, Edson

    2014-01-01

    OBJECTIVE: The aim of this study was to analyze chest CT scans of patients with thoracic textiloma. METHODS: This was a retrospective study of 16 patients (11 men and 5 women) with surgically confirmed thoracic textiloma. The chest CT scans of those patients were evaluated by two independent observers, and discordant results were resolved by consensus. RESULTS: The majority (62.5%) of the textilomas were caused by previous heart surgery. The most common symptoms were chest pain (in 68.75%) and cough (in 56.25%). In all cases, the main tomographic finding was a mass with regular contours and borders that were well-defined or partially defined. Half of the textilomas occurred in the right hemithorax and half occurred in the left. The majority (56.25%) were located in the lower third of the lung. The diameter of the mass was ≤ 10 cm in 10 cases (62.5%) and > 10 cm in the remaining 6 cases (37.5%). Most (81.25%) of the textilomas were heterogeneous in density, with signs of calcification, gas, radiopaque marker, or sponge-like material. Peripheral expansion of the mass was observed in 12 (92.3%) of the 13 patients in whom a contrast agent was used. Intraoperatively, pleural involvement was observed in 14 cases (87.5%) and pericardial involvement was observed in 2 (12.5%). CONCLUSIONS: It is important to recognize the main tomographic aspects of thoracic textilomas in order to include this possibility in the differential diagnosis of chest pain and cough in patients with a history of heart or thoracic surgery, thus promoting the early identification and treatment of this postoperative complication. PMID:25410842

  9. 4D CT sorting based on patient internal anatomy

    NASA Astrophysics Data System (ADS)

    Li, Ruijiang; Lewis, John H.; Cerviño, Laura I.; Jiang, Steve B.

    2009-08-01

    Respiratory motion during free-breathing computed tomography (CT) scan may cause significant errors in target definition for tumors in the thorax and upper abdomen. A four-dimensional (4D) CT technique has been widely used for treatment simulation of thoracic and abdominal cancer radiotherapy. The current 4D CT techniques require retrospective sorting of the reconstructed CT slices oversampled at the same couch position. Most sorting methods depend on external surrogates of respiratory motion recorded by extra instruments. However, respiratory signals obtained from these external surrogates may not always accurately represent the internal target motion, especially when irregular breathing patterns occur. We have proposed a new sorting method based on multiple internal anatomical features for multi-slice CT scan acquired in the cine mode. Four features are analyzed in this study, including the air content, lung area, lung density and body area. We use a measure called spatial coherence to select the optimal internal feature at each couch position and to generate the respiratory signals for 4D CT sorting. The proposed method has been evaluated for ten cancer patients (eight with thoracic cancer and two with abdominal cancer). For nine patients, the respiratory signals generated from the combined internal features are well correlated to those from external surrogates recorded by the real-time position management (RPM) system (average correlation: 0.95 ± 0.02), which is better than any individual internal measures at 95% confidence level. For these nine patients, the 4D CT images sorted by the combined internal features are almost identical to those sorted by the RPM signal. For one patient with an irregular breathing pattern, the respiratory signals given by the combined internal features do not correlate well with those from RPM (correlation: 0.68 ± 0.42). In this case, the 4D CT image sorted by our method presents fewer artifacts than that from the RPM signal. Our

  10. Improved Respiratory Navigator Gating for Thoracic 4D flow MRI

    PubMed Central

    van Ooij, Pim; Semaan, Edouard; Schnell, Susanne; Giri, Shivraman; Stankovic, Zoran; Carr, James; Barker, Alex J.; Markl, Michael

    2016-01-01

    Background Thoracic and abdominal 4D flow MRI is typically acquired in combination with navigator respiration control which can result in highly variable scan efficiency (Seff) and thus total scan time due to inter-individual variability in breathing patterns. The aim of this study was to test the feasibility of an improved respiratory control strategy based on diaphragm navigator gating with fixed Seff, respiratory driven phase encoding, and a navigator training phase. Methods 4D flow MRI of the thoracic aorta was performed in 10 healthy subjects at 1.5T and 3T systems for the in-vivo assessment of aortic time-resolved 3D blood flow velocities. For each subject, four 4D flow scans (1: conventional navigator gating, 2–4: new implementation with fixed Seff =60%, 80% and 100%) were acquired. Data analysis included semi-quantitative evaluation of image quality of the 4D flow magnitude images (image quality grading on a four point scale), 3D segmentation of the thoracic aorta, and voxel-by-voxel comparisons of systolic 3D flow velocity vector fields between scans. Results Conventional navigator gating resulted in variable Seff = 74±13% (range = 56% – 100%) due to inter-individual variability of respiration patterns. For scans 2–4, the the new navigator implementation was able to achieve predictable total scan times with stable Seff, only depending on heart rate. Semi- and fully quantitative analysis of image quality in 4D flow magnitude images was similar for the new navigator scheme compared to conventional navigator gating. For aortic systolic 3D velocities, good agreement was found between all new navigator settings (scan 2–4) with the conventional navigator gating (scan 1) with best performance for Seff = 80% (mean difference = −0.01; limits od agreement = 0.23, Pearson’s ρ=0.89, p <0.001). No significant differences for image quality or 3D systolic velocities were found for 1.5T compared to 3T. Conclusions The findings of this study demonstrate the

  11. Thoracic spine CT scan

    MedlinePlus

    ... Narrowing of the spine ( spinal stenosis ) Scoliosis Tumor Risks Risks of CT scans include: Exposure to radiation ... urac.org). URAC's accreditation program is an independent audit to verify that A.D.A.M. follows ...

  12. Helical mode lung 4D-CT reconstruction using Bayesian model.

    PubMed

    He, Tiancheng; Xue, Zhong; Nitsch, Paige L; Teh, Bin S; Wong, Stephen T

    2013-01-01

    4D computed tomography (CT) has been widely used for treatment planning of thoracic and abdominal cancer radiotherapy. Current 4D-CT lung image reconstruction methods rely on respiratory gating to rearrange the large number of axial images into different phases, which may be subject to external surrogate errors due to poor reproducibility of breathing cycles. New image-matching-based reconstruction works better for the cine mode of 4D-CT acquisition than the helical mode because the table position of each axial image is different in helical mode and image matching might suffer from bigger errors. In helical mode, not only the phases but also the un-uniform table positions of images need to be considered. We propose a Bayesian method for automated 4D-CT lung image reconstruction in helical mode 4D scans. Each axial image is assigned to a respiratory phase based on the Bayesian framework that ensures spatial and temporal smoothness of surfaces of anatomical structures. Iterative optimization is used to reconstruct a series of 3D-CT images for subjects undergoing 4D scans. In experiments, we compared visually and quantitatively the results of the proposed Bayesian 4D-CT reconstruction algorithm with the respiratory surrogate and the image matching-based method. The results showed that the proposed algorithm yielded better 4D-CT for helical scans.

  13. Evaluation of 4D CT acquisition methods designed to reduce artifacts.

    PubMed

    Castillo, Sarah J; Castillo, Richard; Castillo, Edward; Pan, Tinsu; Ibbott, Geoffrey; Balter, Peter; Hobbs, Brian; Guerrero, Thomas

    2015-03-08

    Four-dimensional computed tomography (4D CT) is used to account for respiratory motion in radiation treatment planning, but artifacts resulting from the acquisition and postprocessing limit its accuracy. We investigated the efficacy of three experimental 4D CT acquisition methods to reduce artifacts in a prospective institutional review board approved study. Eighteen thoracic patients scheduled to undergo radiation therapy received standard clinical 4D CT scans followed by each of the alternative 4D CT acquisitions: 1) data oversampling, 2) beam gating with breathing irregularities, and 3) rescanning the clinical acquisition acquired during irregular breathing. Relative values of a validated correlation-based artifact metric (CM) determined the best acquisition method per patient. Each 4D CT was processed by an extended phase sorting approach that optimizes the quantitative artifact metric (CM sorting). The clinical acquisitions were also postprocessed by phase sorting for artifact comparison of our current clinical implementation with the experimental methods. The oversampling acquisition achieved the lowest artifact presence among all acquisitions, achieving a 27% reduction from the current clinical 4D CT implementation (95% confidence interval = 34-20). The rescan method presented a significantly higher artifact presence from the clinical acquisition (37%; p < 0.002), the gating acquisition (26%; p < 0.005), and the oversampling acquisition (31%; p < 0.001), while the data lacked evidence of a significant difference between the clinical, gating, and oversampling methods. The oversampling acquisition reduced artifact presence from the current clinical 4D CT implementation to the largest degree and provided the simplest and most reproducible implementation. The rescan acquisition increased artifact presence significantly, compared to all acquisitions, and suffered from combination of data from independent scans over which large internal anatomic shifts occurred.

  14. Gating and tracking, 4D in thoracic tumours.

    PubMed

    Verellen, D; Depuydt, T; Gevaert, T; Linthout, N; Tournel, K; Duchateau, M; Reynders, T; Storme, G; De Ridder, M

    2010-10-01

    The limited ability to control for a tumour's location compromises the accuracy with which radiation can be delivered to tumour-bearing tissue. The resultant requirement for larger treatment volumes to accommodate target uncertainty restricts the radiation dose because more surrounding normal tissue is exposed. With image-guided radiation therapy (IGRT), these volumes can be optimized and tumouricidal doses may be delivered, achieving maximum tumour control with minimal complications. Moreover, with the ability of high precision dose delivery and real-time knowledge of the target volume location, IGRT has initiated the exploration of new indications in radiotherapy such as hypofractionated radiotherapy (or stereotactic body radiotherapy), deliberate inhomogeneous dose distributions coping with tumour heterogeneity (dose painting by numbers and biologically conformal radiation therapy), and adaptive radiotherapy. In short: "individualized radiotherapy". Tumour motion management, especially for thoracic tumours, is a particular problem in this context both for the delineation of tumours and organs at risk as well as during the actual treatment delivery. The latter will be covered in this paper with some examples based on the experience of the UZ Brussel. With the introduction of the NOVALIS system (BrainLAB, Feldkirchen, Germany) in 2000 and consecutive prototypes of the ExacTrac IGRT system, gradually a hypofractionation treatment protocol was introduced for the treatment of lung tumours and liver metastases evolving from motion-encompassing techniques towards respiratory-gated radiation therapy with audio-visual feedback and most recently dynamic tracking using the VERO system (BrainLAB, Feldkirchen, Germany). This evolution will be used to illustrate the recent developments in this particular field of research.

  15. 4D micro-CT using fast prospective gating

    NASA Astrophysics Data System (ADS)

    Guo, Xiaolian; Johnston, Samuel M.; Qi, Yi; Johnson, G. Allan; Badea, Cristian T.

    2012-01-01

    Micro-CT is currently used in preclinical studies to provide anatomical information. But, there is also significant interest in using this technology to obtain functional information. We report here a new sampling strategy for 4D micro-CT for functional cardiac and pulmonary imaging. Rapid scanning of free-breathing mice is achieved with fast prospective gating (FPG) implemented on a field programmable gate array. The method entails on-the-fly computation of delays from the R peaks of the ECG signals or the peaks of the respiratory signals for the triggering pulses. Projection images are acquired for all cardiac or respiratory phases at each angle before rotating to the next angle. FPG can deliver the faster scan time of retrospective gating (RG) with the regular angular distribution of conventional prospective gating for cardiac or respiratory gating. Simultaneous cardio-respiratory gating is also possible with FPG in a hybrid retrospective/prospective approach. We have performed phantom experiments to validate the new sampling protocol and compared the results from FPG and RG in cardiac imaging of a mouse. Additionally, we have evaluated the utility of incorporating respiratory information in 4D cardiac micro-CT studies with FPG. A dual-source micro-CT system was used for image acquisition with pulsed x-ray exposures (80 kVp, 100 mA, 10 ms). The cardiac micro-CT protocol involves the use of a liposomal blood pool contrast agent containing 123 mg I ml-1 delivered via a tail vein catheter in a dose of 0.01 ml g-1 body weight. The phantom experiment demonstrates that FPG can distinguish the successive phases of phantom motion with minimal motion blur, and the animal study demonstrates that respiratory FPG can distinguish inspiration and expiration. 4D cardiac micro-CT imaging with FPG provides image quality superior to RG at an isotropic voxel size of 88 µm and 10 ms temporal resolution. The acquisition time for either sampling approach is less than 5 min. The

  16. 4D micro-CT using fast prospective gating.

    PubMed

    Guo, Xiaolian; Johnston, Samuel M; Qi, Yi; Johnson, G Allan; Badea, Cristian T

    2012-01-07

    Micro-CT is currently used in preclinical studies to provide anatomical information. But, there is also significant interest in using this technology to obtain functional information. We report here a new sampling strategy for 4D micro-CT for functional cardiac and pulmonary imaging. Rapid scanning of free-breathing mice is achieved with fast prospective gating (FPG) implemented on a field programmable gate array. The method entails on-the-fly computation of delays from the R peaks of the ECG signals or the peaks of the respiratory signals for the triggering pulses. Projection images are acquired for all cardiac or respiratory phases at each angle before rotating to the next angle. FPG can deliver the faster scan time of retrospective gating (RG) with the regular angular distribution of conventional prospective gating for cardiac or respiratory gating. Simultaneous cardio-respiratory gating is also possible with FPG in a hybrid retrospective/prospective approach. We have performed phantom experiments to validate the new sampling protocol and compared the results from FPG and RG in cardiac imaging of a mouse. Additionally, we have evaluated the utility of incorporating respiratory information in 4D cardiac micro-CT studies with FPG. A dual-source micro-CT system was used for image acquisition with pulsed x-ray exposures (80 kVp, 100 mA, 10 ms). The cardiac micro-CT protocol involves the use of a liposomal blood pool contrast agent containing 123 mg I ml(-1) delivered via a tail vein catheter in a dose of 0.01 ml g(-1) body weight. The phantom experiment demonstrates that FPG can distinguish the successive phases of phantom motion with minimal motion blur, and the animal study demonstrates that respiratory FPG can distinguish inspiration and expiration. 4D cardiac micro-CT imaging with FPG provides image quality superior to RG at an isotropic voxel size of 88 μm and 10 ms temporal resolution. The acquisition time for either sampling approach is less than 5 min. The

  17. Brain tissue segmentation in 4D CT using voxel classification

    NASA Astrophysics Data System (ADS)

    van den Boom, R.; Oei, M. T. H.; Lafebre, S.; Oostveen, L. J.; Meijer, F. J. A.; Steens, S. C. A.; Prokop, M.; van Ginneken, B.; Manniesing, R.

    2012-02-01

    A method is proposed to segment anatomical regions of the brain from 4D computer tomography (CT) patient data. The method consists of a three step voxel classification scheme, each step focusing on structures that are increasingly difficult to segment. The first step classifies air and bone, the second step classifies vessels and the third step classifies white matter, gray matter and cerebrospinal fluid. As features the time averaged intensity value and the temporal intensity change value were used. In each step, a k-Nearest-Neighbor classifier was used to classify the voxels. Training data was obtained by placing regions of interest in reconstructed 3D image data. The method has been applied to ten 4D CT cerebral patient data. A leave-one-out experiment showed consistent and accurate segmentation results.

  18. Realistic CT simulation using the 4D XCAT phantom.

    PubMed

    Segars, W P; Mahesh, M; Beck, T J; Frey, E C; Tsui, B M W

    2008-08-01

    The authors develop a unique CT simulation tool based on the 4D extended cardiac-torso (XCAT) phantom, a whole-body computer model of the human anatomy and physiology based on NURBS surfaces. Unlike current phantoms in CT based on simple mathematical primitives, the 4D XCAT provides an accurate representation of the complex human anatomy and has the advantage, due to its design, that its organ shapes can be changed to realistically model anatomical variations and patient motion. A disadvantage to the NURBS basis of the XCAT, however, is that the mathematical complexity of the surfaces makes the calculation of line integrals through the phantom difficult. They have to be calculated using iterative procedures; therefore, the calculation of CT projections is much slower than for simpler mathematical phantoms. To overcome this limitation, the authors used efficient ray tracing techniques from computer graphics, to develop a fast analytic projection algorithm to accurately calculate CT projections directly from the surface definition of the XCAT phantom given parameters defining the CT scanner and geometry. Using this tool, realistic high-resolution 3D and 4D projection images can be simulated and reconstructed from the XCAT within a reasonable amount of time. In comparison with other simulators with geometrically defined organs, the XCAT-based algorithm was found to be only three times slower in generating a projection data set of the same anatomical structures using a single 3.2 GHz processor. To overcome this decrease in speed would, therefore, only require running the projection algorithm in parallel over three processors. With the ever decreasing cost of computers and the rise of faster processors and multi-processor systems and clusters, this slowdown is basically inconsequential, especially given the vast improvement the XCAT offers in terms of realism and the ability to generate 3D and 4D data from anatomically diverse patients. As such, the authors conclude

  19. CT and MRI in the Evaluation of Thoracic Aortic Diseases

    PubMed Central

    2013-01-01

    Computed tomography (CT) and magnetic resonance imaging (MRI) are the most commonly used imaging examinations to evaluate thoracic aortic diseases because of their high spatial and temporal resolutions, large fields of view, and multiplanar imaging reconstruction capabilities. CT and MRI play an important role not only in the diagnosis of thoracic aortic disease but also in the preoperative assessment and followup after treatment. In this review, the CT and MRI appearances of various acquired thoracic aortic conditions are described and illustrated. PMID:24396601

  20. TH-E-17A-07: Improved Cine Four-Dimensional Computed Tomography (4D CT) Acquisition and Processing Method

    SciTech Connect

    Castillo, S; Castillo, R; Castillo, E; Pan, T; Ibbott, G; Balter, P; Hobbs, B; Dai, J; Guerrero, T

    2014-06-15

    Purpose: Artifacts arising from the 4D CT acquisition and post-processing methods add systematic uncertainty to the treatment planning process. We propose an alternate cine 4D CT acquisition and post-processing method to consistently reduce artifacts, and explore patient parameters indicative of image quality. Methods: In an IRB-approved protocol, 18 patients with primary thoracic malignancies received a standard cine 4D CT acquisition followed by an oversampling 4D CT that doubled the number of images acquired. A second cohort of 10 patients received the clinical 4D CT plus 3 oversampling scans for intra-fraction reproducibility. The clinical acquisitions were processed by the standard phase sorting method. The oversampling acquisitions were processed using Dijkstras algorithm to optimize an artifact metric over available image data. Image quality was evaluated with a one-way mixed ANOVA model using a correlation-based artifact metric calculated from the final 4D CT image sets. Spearman correlations and a linear mixed model tested the association between breathing parameters, patient characteristics, and image quality. Results: The oversampling 4D CT scans reduced artifact presence significantly by 27% and 28%, for the first cohort and second cohort respectively. From cohort 2, the inter-replicate deviation for the oversampling method was within approximately 13% of the cross scan average at the 0.05 significance level. Artifact presence for both clinical and oversampling methods was significantly correlated with breathing period (ρ=0.407, p-value<0.032 clinical, ρ=0.296, p-value<0.041 oversampling). Artifact presence in the oversampling method was significantly correlated with amount of data acquired, (ρ=-0.335, p-value<0.02) indicating decreased artifact presence with increased breathing cycles per scan location. Conclusion: The 4D CT oversampling acquisition with optimized sorting reduced artifact presence significantly and reproducibly compared to the phase

  1. Impact of CT attenuation correction method on quantitative respiratory-correlated (4D) PET/CT imaging

    SciTech Connect

    Nyflot, Matthew J.; Lee, Tzu-Cheng; Alessio, Adam M.; Kinahan, Paul E.; Wollenweber, Scott D.; Stearns, Charles W.; Bowen, Stephen R.

    2015-01-15

    Purpose: Respiratory-correlated positron emission tomography (PET/CT) 4D PET/CT is used to mitigate errors from respiratory motion; however, the optimal CT attenuation correction (CTAC) method for 4D PET/CT is unknown. The authors performed a phantom study to evaluate the quantitative performance of CTAC methods for 4D PET/CT in the ground truth setting. Methods: A programmable respiratory motion phantom with a custom movable insert designed to emulate a lung lesion and lung tissue was used for this study. The insert was driven by one of five waveforms: two sinusoidal waveforms or three patient-specific respiratory waveforms. 3DPET and 4DPET images of the phantom under motion were acquired and reconstructed with six CTAC methods: helical breath-hold (3DHEL), helical free-breathing (3DMOT), 4D phase-averaged (4DAVG), 4D maximum intensity projection (4DMIP), 4D phase-matched (4DMATCH), and 4D end-exhale (4DEXH) CTAC. Recovery of SUV{sub max}, SUV{sub mean}, SUV{sub peak}, and segmented tumor volume was evaluated as RC{sub max}, RC{sub mean}, RC{sub peak}, and RC{sub vol}, representing percent difference relative to the static ground truth case. Paired Wilcoxon tests and Kruskal–Wallis ANOVA were used to test for significant differences. Results: For 4DPET imaging, the maximum intensity projection CTAC produced significantly more accurate recovery coefficients than all other CTAC methods (p < 0.0001 over all metrics). Over all motion waveforms, ratios of 4DMIP CTAC recovery were 0.2 ± 5.4, −1.8 ± 6.5, −3.2 ± 5.0, and 3.0 ± 5.9 for RC{sub max}, RC{sub peak}, RC{sub mean}, and RC{sub vol}. In comparison, recovery coefficients for phase-matched CTAC were −8.4 ± 5.3, −10.5 ± 6.2, −7.6 ± 5.0, and −13.0 ± 7.7 for RC{sub max}, RC{sub peak}, RC{sub mean}, and RC{sub vol}. When testing differences between phases over all CTAC methods and waveforms, end-exhale phases were significantly more accurate (p = 0.005). However, these differences were driven by

  2. Fast X-ray micro-CT for real-time 4D observation

    NASA Astrophysics Data System (ADS)

    Takano, H.; Yoshida, K.; Tsuji, T.; Koyama, T.; Tsusaka, Y.; Kagoshima, Y.

    2009-09-01

    Fast X-ray computed tomography (CT) system with sub-second order measurement for single CT acquisition has been developed. The system, consisting of a high-speed sample rotation stage and a high-speed X-ray camera, is constructed at synchrotron radiation beamline in order to utilize fully intense X-rays. A time-resolving CT movie (i.e. 4D CT) can be available by operating the fast CT system continuously. Real-time observation of water absorbing process of super-absorbent polymer (SAP) has been successfully performed with the 4D CT operation.

  3. Mapping motion from 4D-MRI to 3D-CT for use in 4D dose calculations: A technical feasibility study

    SciTech Connect

    Boye, Dirk; Lomax, Tony; Knopf, Antje

    2013-06-15

    Purpose: Target sites affected by organ motion require a time resolved (4D) dose calculation. Typical 4D dose calculations use 4D-CT as a basis. Unfortunately, 4D-CT images have the disadvantage of being a 'snap-shot' of the motion during acquisition and of assuming regularity of breathing. In addition, 4D-CT acquisitions involve a substantial additional dose burden to the patient making many, repeated 4D-CT acquisitions undesirable. Here the authors test the feasibility of an alternative approach to generate patient specific 4D-CT data sets. Methods: In this approach motion information is extracted from 4D-MRI. Simulated 4D-CT data sets [which the authors call 4D-CT(MRI)] are created by warping extracted deformation fields to a static 3D-CT data set. The employment of 4D-MRI sequences for this has the advantage that no assumptions on breathing regularity are made, irregularities in breathing can be studied and, if necessary, many repeat imaging studies (and consequently simulated 4D-CT data sets) can be performed on patients and/or volunteers. The accuracy of 4D-CT(MRI)s has been validated by 4D proton dose calculations. Our 4D dose algorithm takes into account displacements as well as deformations on the originating 4D-CT/4D-CT(MRI) by calculating the dose of each pencil beam based on an individual time stamp of when that pencil beam is applied. According to corresponding displacement and density-variation-maps the position and the water equivalent range of the dose grid points is adjusted at each time instance. Results: 4D dose distributions, using 4D-CT(MRI) data sets as input were compared to results based on a reference conventional 4D-CT data set capturing similar motion characteristics. Almost identical 4D dose distributions could be achieved, even though scanned proton beams are very sensitive to small differences in the patient geometry. In addition, 4D dose calculations have been performed on the same patient, but using 4D-CT(MRI) data sets based on

  4. Quantitative Analysis of Vortical Blood Flow in the Thoracic Aorta Using 4D Phase Contrast MRI

    PubMed Central

    von Spiczak, Jochen; Crelier, Gerard; Giese, Daniel; Kozerke, Sebastian; Maintz, David; Bunck, Alexander Christian

    2015-01-01

    4D phase contrast MRI. Vortex blood flow in the thoracic aorta could be consistently described in all healthy volunteers. In patient data, pathologically altered vortex flow was observed. PMID:26418327

  5. Actively triggered 4d cone-beam CT acquisition

    SciTech Connect

    Fast, Martin F.; Wisotzky, Eric; Oelfke, Uwe; Nill, Simeon

    2013-09-15

    Purpose: 4d cone-beam computed tomography (CBCT) scans are usually reconstructed by extracting the motion information from the 2d projections or an external surrogate signal, and binning the individual projections into multiple respiratory phases. In this “after-the-fact” binning approach, however, projections are unevenly distributed over respiratory phases resulting in inefficient utilization of imaging dose. To avoid excess dose in certain respiratory phases, and poor image quality due to a lack of projections in others, the authors have developed a novel 4d CBCT acquisition framework which actively triggers 2d projections based on the forward-predicted position of the tumor.Methods: The forward-prediction of the tumor position was independently established using either (i) an electromagnetic (EM) tracking system based on implanted EM-transponders which act as a surrogate for the tumor position, or (ii) an external motion sensor measuring the chest-wall displacement and correlating this external motion to the phase-shifted diaphragm motion derived from the acquired images. In order to avoid EM-induced artifacts in the imaging detector, the authors devised a simple but effective “Faraday” shielding cage. The authors demonstrated the feasibility of their acquisition strategy by scanning an anthropomorphic lung phantom moving on 1d or 2d sinusoidal trajectories.Results: With both tumor position devices, the authors were able to acquire 4d CBCTs free of motion blurring. For scans based on the EM tracking system, reconstruction artifacts stemming from the presence of the EM-array and the EM-transponders were greatly reduced using newly developed correction algorithms. By tuning the imaging frequency independently for each respiratory phase prior to acquisition, it was possible to harmonize the number of projections over respiratory phases. Depending on the breathing period (3.5 or 5 s) and the gantry rotation time (4 or 5 min), between ∼90 and 145

  6. CT and MR imaging of the thoracic aorta

    PubMed Central

    Splendiani, Alessandra; Barile, Antonio; Squillaci, Ettore; Di Cesare, Annamaria; Brunese, Luca; Masciocchi, Carlo

    2016-01-01

    Abstract At present time, both CT and MRI are valuable techniques in the study of the thoracic aorta. Nowadays, CT represents the most widely employed technique for the study of the thoracic aorta. The new generation CTs show sensitivities up to 100% and specificities of 98-99%. Sixteen and wider row detectors provide isotropic pixels, mandatory for the ineludible longitudinal reconstruction. The main limits are related to the X-ray dose expoure and the use of iodinated contrast media. MRI has great potential in the study of the thoracic aorta. Nevertheless, if compared to CT, acquisition times remain longer and movement artifact susceptibility higher. The main MRI disadvantages are claustrophobia, presence of ferromagnetic implants, pacemakers, longer acquisition times with respect to CT, inability to use contrast media in cases of renal insufficiency, lower spatial resolution and less availability than CT. CT is preferred in the acute aortic disease. Nevertheless, since it requires iodinated contrast media and X-ray exposure, it may be adequately replaced by MRI in the follow up of aortic diseases. The main limitation of MRI, however, is related to the scarce visibility of stents and calcifications. PMID:28352783

  7. SU-E-J-187: Individually Optimized Contrast-Enhancement 4D-CT for Pancreatic Adenocarcinoma in Radiotherapy Simulation

    SciTech Connect

    Xue, M; Patel, K; Regine, W; Lane, B; D'Souza, W; Lu, W; Klahr, P

    2014-06-01

    Purpose: To study the feasibility of individually optimized contrastenhancement (CE) 4D-CT for pancreatic adenocarcinoma (PDA) in radiotherapy simulation. To evaluate the image quality and contrast enhancement of tumor in the CE 4D-CT, compared to the clinical standard of CE 3D-CT and 4D-CT. Methods: In this IRB-approved study, each of the 7 PDA patients enrolled underwent 3 CT scans: a free-breathing 3D-CT with contrast (CE 3D-CT) followed by a 4D-CT without contrast (4D-CT) in the first study session, and a 4D-CT with individually synchronized contrast injection (CE 4D-CT) in the second study session. In CE 4D-CT, the time of full contrast injection was determined based on the time of peak enhancement for the test injection, injection rate, table speed, and longitudinal location and span of the pancreatic region. Physicians contoured both the tumor (T) and the normal pancreatic parenchyma (P) on the three CTs (end-of-exhalation for 4D-CT). The contrast between the tumor and normal pancreatic tissue was computed as the difference of the mean enhancement level of three 1 cm3 regions of interests in T and P, respectively. Wilcoxon rank sum test was used to statistically compare the scores and contrasts. Results: In qualitative evaluations, both CE 3D-CT and CE 4D-CT scored significantly better than 4D-CT (4.0 and 3.6 vs. 2.6). There was no significant difference between CE 3D-CT and CE 4D-CT. In quantitative evaluations, the contrasts between the tumor and the normal pancreatic parenchyma were 0.6±23.4, −2.1±8.0, and −19.6±28.8 HU, in CE 3D-CT, 4D-CT, and CE 4D-CT, respectively. Although not statistically significant, CE 4D-CT achieved better contrast enhancement between the tumor and the normal pancreatic parenchyma than both CE 3D-CT and 4DCT. Conclusion: CE 4D-CT achieved equivalent image quality and better contrast enhancement between tumor and normal pancreatic parenchyma than the clinical standard of CE 3D-CT and 4D-CT. This study was supported in part

  8. TH-E-BRF-02: 4D-CT Ventilation Image-Based IMRT Plans Are Dosimetrically Comparable to SPECT Ventilation Image-Based Plans

    SciTech Connect

    Kida, S; Bal, M; Kabus, S; Loo, B; Keall, P; Yamamoto, T

    2014-06-15

    Purpose: An emerging lung ventilation imaging method based on 4D-CT can be used in radiotherapy to selectively avoid irradiating highly-functional lung regions, which may reduce pulmonary toxicity. Efforts to validate 4DCT ventilation imaging have been focused on comparison with other imaging modalities including SPECT and xenon CT. The purpose of this study was to compare 4D-CT ventilation image-based functional IMRT plans with SPECT ventilation image-based plans as reference. Methods: 4D-CT and SPECT ventilation scans were acquired for five thoracic cancer patients in an IRB-approved prospective clinical trial. The ventilation images were created by quantitative analysis of regional volume changes (a surrogate for ventilation) using deformable image registration of the 4D-CT images. A pair of 4D-CT ventilation and SPECT ventilation image-based IMRT plans was created for each patient. Regional ventilation information was incorporated into lung dose-volume objectives for IMRT optimization by assigning different weights on a voxel-by-voxel basis. The objectives and constraints of the other structures in the plan were kept identical. The differences in the dose-volume metrics have been evaluated and tested by a paired t-test. SPECT ventilation was used to calculate the lung functional dose-volume metrics (i.e., mean dose, V20 and effective dose) for both 4D-CT ventilation image-based and SPECT ventilation image-based plans. Results: Overall there were no statistically significant differences in any dose-volume metrics between the 4D-CT and SPECT ventilation imagebased plans. For example, the average functional mean lung dose of the 4D-CT plans was 26.1±9.15 (Gy), which was comparable to 25.2±8.60 (Gy) of the SPECT plans (p = 0.89). For other critical organs and PTV, nonsignificant differences were found as well. Conclusion: This study has demonstrated that 4D-CT ventilation image-based functional IMRT plans are dosimetrically comparable to SPECT ventilation image

  9. SU-E-J-148: Tools for Development of 4D Proton CT

    SciTech Connect

    Dou, T; Ramos-Mendez, J; Piersimoni, P; Giacometti, V; Penfold, S; Censor, Y; Faddegon, B; Low, D; Schulte, R

    2015-06-15

    Purpose: To develop tools for performing 4D proton computed tomography (CT). Methods: A suitable patient with a tumor in the right lower lobe was selected from a set of 4D CT scans. The volumetric CT images formed the basis for calculating the parameters of a breathing model that allows reconstruction of a static reference CT and CT images in each breathing phase. The images were imported into the TOPAS Monte Carlo simulation platform for simulating an experimental proton CT scan with 45 projections spaced by 4 degree intervals. Each projection acquired data for 2 seconds followed by a gantry rotation for 2 seconds without acquisition. The scan covered 180 degrees with individual protons passing through a 9-cm slab of the patient’s lung covering the moving tumor. An initial proton energy sufficient for penetrating the patient from all directions was determined. Performing the proton CT simulation, TOPAS provided output of the proton energy and coordinates registered in two planes before and after the patient, respectively. The set of projection data was then used with an iterative reconstruction algorithm to generate a volumetric proton CT image set of the static reference image and the image obtained under breathing motion, respectively. Results: An initial proton energy of 230 MeV was found to be sufficient, while for an initial energy of 200 MeV a substantial number of protons did not penetrate the patient. The reconstruction of the static reference image set provided sufficient detail for treatment planning. Conclusion: We have developed tools to perform studies of proton CT in the presence of lung motion based on the TOPAS simulation toolkit. This will allow to optimize 4D reconstruction algorithms by synchronizing the acquired proton CT data with a breathing signal and utilizing a breathing model obtained prior to the proton CT scan. This research has been supported by the National Institute Of Biomedical Imaging And Bioengineering of the National

  10. Preoperative localization of hyperfunctioning parathyroid glands with 4D-CT.

    PubMed

    Lundstroem, Anke Katrin; Trolle, Waldemar; Soerensen, Christian Hjort; Myschetzky, Peter Sand

    2016-05-01

    Primary hyperparathyroidism (pHPT) is almost exclusively the result of a solitary parathyroid adenoma. In most cases, the affected gland can be surgically removed, but precise preoperative imaging is essential for adenoma localization prior to surgical intervention. In this study, we evaluated the diagnostic value of four-dimensional computed tomography (4D-CT) as a preoperative imaging tool in relation to the localization of pathologic parathyroid glands in patients with pHPT and negative sestamibi scans. This study included 43 consecutive patients with pHPT referred for parathyroidectomy at the Department of Head and Neck Surgery of Copenhagen University Hospital Rigshospitalet in 2011 and 2012. All patients had a 4D-CT performed prior to parathyroidectomy. CT localization of the suspected adenoma was correlated to the actual surgical findings and subsequent histological diagnosis was also available as references for the accuracy of this imaging tool. Hyperfunctioning parathyroid glands were found in 40 patients. 4D-CT identified 32 solitary hyperfunctioning parathyroid glands located on the correct side of the neck (PPV 76 %) and 21 located within the correct quadrant (PPV 49 %). Unilateral resection was performed in 72 % of patients due to the localization findings of preoperative imaging. 4D-CT can, therefore, be considered an effective method for the preoperative localization of parathyroid adenomas and is an important tool in surgical intervention for patients referred to parathyroidectomy.

  11. A phantom for testing of 4D-CT for radiotherapy of small lesions

    SciTech Connect

    Dunn, L.; Kron, T.; Taylor, M. L.; Callahan, J.; Franich, R. D.

    2012-09-15

    Purpose: The use of time-resolved four-dimensional computed tomography (4D-CT) in radiotherapy requires strict quality assurance to ensure the accuracy of motion management protocols. The aim of this work was to design and test a phantom capable of large amplitude motion for use in 4D-CT, with particular interest in small lesions typical for stereotactic body radiotherapy. Methods: The phantom of 'see-saw' design is light weight, capable of including various sample materials and compatible with several surrogate marker signal acquisition systems. It is constructed of polymethylmethacrylate (Perspex) and its movement is controlled via a dc motor and drive wheel. It was tested using two CT scanners with different 4D acquisition methods: the Philips Brilliance Big Bore CT (helical scan, pressure belt) and a General Electric Discovery STE PET/CT (axial scan, infrared marker). Amplitudes ranging from 1.5 to 6.0 cm and frequencies of up to 40 cycles per minute were used to study the effect of motion on image quality. Maximum intensity projections (MIPs), as well as average intensity projections (AIPs) of moving objects were investigated and their quality dependence on the number of phase reconstruction bins assessed. Results: CT number discrepancies between moving and stationary objects were found to have no systematic dependence on amplitude, frequency, or specific interphase variability. MIP-delineated amplitudes of motion were found to match physical phantom amplitudes to within 2 mm for all motion scenarios tested. Objects undergoing large amplitude motions (>3.0 cm) were shown to cause artefacts in MIP and AIP projections when ten phase bins were assigned. This problem can be mitigated by increasing the number of phase bins in a 4D-CT scan. Conclusions: The phantom was found to be a suitable tool for evaluating the image quality of 4D-CT motion management technology, as well as providing a quality assurance tool for intercenter/intervendor testing of commercial 4D-CT

  12. Resolution enhancement of lung 4D-CT via group-sparsity

    SciTech Connect

    Bhavsar, Arnav; Wu, Guorong; Shen, Dinggang; Lian, Jun

    2013-12-15

    Purpose: 4D-CT typically delivers more accurate information about anatomical structures in the lung, over 3D-CT, due to its ability to capture visual information of the lung motion across different respiratory phases. This helps to better determine the dose during radiation therapy for lung cancer. However, a critical concern with 4D-CT that substantially compromises this advantage is the low superior-inferior resolution due to less number of acquired slices, in order to control the CT radiation dose. To address this limitation, the authors propose an approach to reconstruct missing intermediate slices, so as to improve the superior-inferior resolution.Methods: In this method the authors exploit the observation that sampling information across respiratory phases in 4D-CT can be complimentary due to lung motion. The authors’ approach uses this locally complimentary information across phases in a patch-based sparse-representation framework. Moreover, unlike some recent approaches that treat local patches independently, the authors’ approach employs the group-sparsity framework that imposes neighborhood and similarity constraints between patches. This helps in mitigating the trade-off between noise robustness and structure preservation, which is an important consideration in resolution enhancement. The authors discuss the regularizing ability of group-sparsity, which helps in reducing the effect of noise and enables better structural localization and enhancement.Results: The authors perform extensive experiments on the publicly available DIR-Lab Lung 4D-CT dataset [R. Castillo, E. Castillo, R. Guerra, V. Johnson, T. McPhail, A. Garg, and T. Guerrero, “A framework for evaluation of deformable image registration spatial accuracy using large landmark point sets,” Phys. Med. Biol. 54, 1849–1870 (2009)]. First, the authors carry out empirical parametric analysis of some important parameters in their approach. The authors then demonstrate, qualitatively as well as

  13. 4D micro-CT for cardiac and perfusion applications with view under sampling.

    PubMed

    Badea, Cristian T; Johnston, Samuel M; Qi, Yi; Johnson, G Allan

    2011-06-07

    Micro-CT is commonly used in preclinical studies to provide anatomical information. There is growing interest in obtaining functional measurements from 4D micro-CT. We report here strategies for 4D micro-CT with a focus on two applications: (i) cardiac imaging based on retrospective gating and (ii) pulmonary perfusion using multiple contrast injections/rotations paradigm. A dual source micro-CT system is used for image acquisition with a sampling rate of 20 projections per second. The cardiac micro-CT protocol involves the use of a liposomal blood pool contrast agent. Fast scanning of free breathing mice is achieved using retrospective gating. The ECG and respiratory signals are used to sort projections into ten cardiac phases. The pulmonary perfusion protocol uses a conventional contrast agent (Isovue 370) delivered by a micro-injector in four injections separated by 2 min intervals to allow for clearance. Each injection is synchronized with the rotation of the animal, and each of the four rotations is started with an angular offset of 22.5 from the starting angle of the previous rotation. Both cardiac and perfusion protocols result in an irregular angular distribution of projections that causes significant streaking artifacts in reconstructions when using traditional filtered backprojection (FBP) algorithms. The reconstruction involves the use of the point spread function of the micro-CT system for each time point, and the analysis of the distribution of the reconstructed data in the Fourier domain. This enables us to correct for angular inconsistencies via deconvolution and identify regions where data is missing. The missing regions are filled with data from a high quality but temporally averaged prior image reconstructed with all available projections. Simulations indicate that deconvolution successfully removes the streaking artifacts while preserving temporal information. 4D cardiac micro-CT in a mouse was performed with adequate image quality at isotropic

  14. Directional sinogram interpolation for motion weighted 4D cone-beam CT reconstruction

    NASA Astrophysics Data System (ADS)

    Zhang, Hua; Kruis, Matthijs; Sonke, Jan-Jakob

    2017-03-01

    The image quality of respiratory sorted four-dimensional (4D) cone-beam (CB) computed tomography (CT) is often limited by streak artifacts due to insufficient projections. A motion weighted reconstruction (MWR) method is proposed to decrease streak artifacts and improve image quality. Firstly, respiratory correlated CBCT projections were interpolated by directional sinogram interpolation (DSI) to generate additional CB projections for each phase and subsequently reconstructed. Secondly, local motion was estimated by deformable image registration of the interpolated 4D CBCT. Thirdly, a regular 3D FDK CBCT was reconstructed from the non-interpolated projections. Finally, weights were assigned to each voxel, based on the local motion, and then were used to combine the 3D FDK CBCT and interpolated 4D CBCT to generate the final 4D image. MWR method was compared with regular 4D CBCT scans as well as McKinnon and Bates (MKB) based reconstructions. Comparisons were made in terms of (1) comparing the steepness of an extracted profile from the boundary of the region-of-interest (ROI), (2) contrast-to-noise ratio (CNR) inside certain ROIs, and (3) the root-mean-square-error (RMSE) between the planning CT and CBCT inside a homogeneous moving region. Comparisons were made for both a phantom and four patient scans. In a 4D phantom, RMSE were reduced by 24.7% and 38.7% for MKB and MWR respectively, compared to conventional 4D CBCT. Meanwhile, interpolation induced blur was minimal in static regions for MWR based reconstructions. In regions with considerable respiratory motion, image blur using MWR is less than the MKB and 3D Feldkamp (FDK) methods. In the lung cancer patients, average CNRs of MKB, DSI and MWR improved by a factor 1.7, 2.8 and 3.5 respectively relative to 4D FDK. MWR effectively reduces RMSE in 4D cone-beam CT and improves the image quality in both the static and respiratory moving regions compared to 4D FDK and MKB methods.

  15. Statistical 4D graphs for multi-organ abdominal segmentation from multiphase CT.

    PubMed

    Linguraru, Marius George; Pura, John A; Pamulapati, Vivek; Summers, Ronald M

    2012-05-01

    The interpretation of medical images benefits from anatomical and physiological priors to optimize computer-aided diagnosis applications. Diagnosis also relies on the comprehensive analysis of multiple organs and quantitative measures of soft tissue. An automated method optimized for medical image data is presented for the simultaneous segmentation of four abdominal organs from 4D CT data using graph cuts. Contrast-enhanced CT scans were obtained at two phases: non-contrast and portal venous. Intra-patient data were spatially normalized by non-linear registration. Then 4D convolution using population training information of contrast-enhanced liver, spleen and kidneys was applied to multiphase data to initialize the 4D graph and adapt to patient-specific data. CT enhancement information and constraints on shape, from Parzen windows, and location, from a probabilistic atlas, were input into a new formulation of a 4D graph. Comparative results demonstrate the effects of appearance, enhancement, shape and location on organ segmentation. All four abdominal organs were segmented robustly and accurately with volume overlaps over 93.6% and average surface distances below 1.1mm.

  16. Geometric validation of self-gating k-space-sorted 4D-MRI vs 4D-CT using a respiratory motion phantom

    PubMed Central

    Yue, Yong; Fan, Zhaoyang; Yang, Wensha; Pang, Jianing; Deng, Zixin; McKenzie, Elizabeth; Tuli, Richard; Wallace, Robert; Li, Debiao; Fraass, Benedick

    2015-01-01

    Purpose: MRI is increasingly being used for radiotherapy planning, simulation, and in-treatment-room motion monitoring. To provide more detailed temporal and spatial MR data for these tasks, we have recently developed a novel self-gated (SG) MRI technique with advantage of k-space phase sorting, high isotropic spatial resolution, and high temporal resolution. The current work describes the validation of this 4D-MRI technique using a MRI- and CT-compatible respiratory motion phantom and comparison to 4D-CT. Methods: The 4D-MRI sequence is based on a spoiled gradient echo-based 3D projection reconstruction sequence with self-gating for 4D-MRI at 3 T. Respiratory phase is resolved by using SG k-space lines as the motion surrogate. 4D-MRI images are reconstructed into ten temporal bins with spatial resolution 1.56 × 1.56 × 1.56 mm3. A MRI-CT compatible phantom was designed to validate the performance of the 4D-MRI sequence and 4D-CT imaging. A spherical target (diameter 23 mm, volume 6.37 ml) filled with high-concentration gadolinium (Gd) gel is embedded into a plastic box (35 × 40 × 63 mm3) and stabilized with low-concentration Gd gel. The phantom, driven by an air pump, is able to produce human-type breathing patterns between 4 and 30 respiratory cycles/min. 4D-CT of the phantom has been acquired in cine mode, and reconstructed into ten phases with slice thickness 1.25 mm. The 4D images sets were imported into a treatment planning software for target contouring. The geometrical accuracy of the 4D MRI and CT images has been quantified using target volume, flattening, and eccentricity. The target motion was measured by tracking the centroids of the spheres in each individual phase. Motion ground-truth was obtained from input signals and real-time video recordings. Results: The dynamic phantom has been operated in four respiratory rate (RR) settings, 6, 10, 15, and 20/min, and was scanned with 4D-MRI and 4D-CT. 4D-CT images have target-stretching, partial

  17. Geometric validation of self-gating k-space-sorted 4D-MRI vs 4D-CT using a respiratory motion phantom

    SciTech Connect

    Yue, Yong Yang, Wensha; McKenzie, Elizabeth; Tuli, Richard; Wallace, Robert; Fraass, Benedick; Fan, Zhaoyang; Pang, Jianing; Deng, Zixin; Li, Debiao

    2015-10-15

    Purpose: MRI is increasingly being used for radiotherapy planning, simulation, and in-treatment-room motion monitoring. To provide more detailed temporal and spatial MR data for these tasks, we have recently developed a novel self-gated (SG) MRI technique with advantage of k-space phase sorting, high isotropic spatial resolution, and high temporal resolution. The current work describes the validation of this 4D-MRI technique using a MRI- and CT-compatible respiratory motion phantom and comparison to 4D-CT. Methods: The 4D-MRI sequence is based on a spoiled gradient echo-based 3D projection reconstruction sequence with self-gating for 4D-MRI at 3 T. Respiratory phase is resolved by using SG k-space lines as the motion surrogate. 4D-MRI images are reconstructed into ten temporal bins with spatial resolution 1.56 × 1.56 × 1.56 mm{sup 3}. A MRI-CT compatible phantom was designed to validate the performance of the 4D-MRI sequence and 4D-CT imaging. A spherical target (diameter 23 mm, volume 6.37 ml) filled with high-concentration gadolinium (Gd) gel is embedded into a plastic box (35 × 40 × 63 mm{sup 3}) and stabilized with low-concentration Gd gel. The phantom, driven by an air pump, is able to produce human-type breathing patterns between 4 and 30 respiratory cycles/min. 4D-CT of the phantom has been acquired in cine mode, and reconstructed into ten phases with slice thickness 1.25 mm. The 4D images sets were imported into a treatment planning software for target contouring. The geometrical accuracy of the 4D MRI and CT images has been quantified using target volume, flattening, and eccentricity. The target motion was measured by tracking the centroids of the spheres in each individual phase. Motion ground-truth was obtained from input signals and real-time video recordings. Results: The dynamic phantom has been operated in four respiratory rate (RR) settings, 6, 10, 15, and 20/min, and was scanned with 4D-MRI and 4D-CT. 4D-CT images have target

  18. A hybrid reconstruction algorithm for fast and accurate 4D cone-beam CT imaging

    SciTech Connect

    Yan, Hao; Folkerts, Michael; Jiang, Steve B. E-mail: steve.jiang@UTSouthwestern.edu; Jia, Xun E-mail: steve.jiang@UTSouthwestern.edu; Zhen, Xin; Li, Yongbao; Pan, Tinsu; Cervino, Laura

    2014-07-15

    Purpose: 4D cone beam CT (4D-CBCT) has been utilized in radiation therapy to provide 4D image guidance in lung and upper abdomen area. However, clinical application of 4D-CBCT is currently limited due to the long scan time and low image quality. The purpose of this paper is to develop a new 4D-CBCT reconstruction method that restores volumetric images based on the 1-min scan data acquired with a standard 3D-CBCT protocol. Methods: The model optimizes a deformation vector field that deforms a patient-specific planning CT (p-CT), so that the calculated 4D-CBCT projections match measurements. A forward-backward splitting (FBS) method is invented to solve the optimization problem. It splits the original problem into two well-studied subproblems, i.e., image reconstruction and deformable image registration. By iteratively solving the two subproblems, FBS gradually yields correct deformation information, while maintaining high image quality. The whole workflow is implemented on a graphic-processing-unit to improve efficiency. Comprehensive evaluations have been conducted on a moving phantom and three real patient cases regarding the accuracy and quality of the reconstructed images, as well as the algorithm robustness and efficiency. Results: The proposed algorithm reconstructs 4D-CBCT images from highly under-sampled projection data acquired with 1-min scans. Regarding the anatomical structure location accuracy, 0.204 mm average differences and 0.484 mm maximum difference are found for the phantom case, and the maximum differences of 0.3–0.5 mm for patients 1–3 are observed. As for the image quality, intensity errors below 5 and 20 HU compared to the planning CT are achieved for the phantom and the patient cases, respectively. Signal-noise-ratio values are improved by 12.74 and 5.12 times compared to results from FDK algorithm using the 1-min data and 4-min data, respectively. The computation time of the algorithm on a NVIDIA GTX590 card is 1–1.5 min per phase

  19. Thoracic cancer imaging with PET/CT in radiation oncology

    NASA Astrophysics Data System (ADS)

    Chi, Pai-Chun Melinda

    Significance. Respiratory motion has been shown to cause artifacts in PET/CT imaging. This breathing artifact can have a significant impact on PET quantification and it can lead to large uncertainties when using PET for radiation therapy planning. We have demonstrated a promising solution to resolve the breathing artifact by acquiring respiration-averaged CT (ACT) for PET/CT. The purpose of this work was to optimize the ACT acquisition for clinical implementation and to evaluate the impact of ACT on PET/CT quantification. The hypothesis was that ACT is an effective method in removing the breathing artifact when compared to our current clinical protocol. Methods. Phase and cine approaches for acquiring ACT were investigated and the results of these two approaches were compared to the ACT generated from clinical 4DCT data sets (abbreviated as ACT10phs ). In the phase approach, ACT was generated based on combinations of selected respiratory phases; in the cine approach, ACT was generated based on cine images acquired over a fixed cine duration. The phase combination and cine duration that best approximated the ACT10phs were determined to be the optimized scanning parameters. 216 thoracic PET/CT patients were scanned with both current clinical and the ACT protocols. The effects of ACT on PET/CT quantification were assessed by comparing clinical PET/CT and ACT PET/CT using 3 metrics: PET/CT image alignment, maximum standardized uptake value (SUVmax), and threshold segmented gross tumor volume (GTV). Results. ACT10phs can be best approximated to within 2% of SUV variation by phase averaging based on 4 representative phases, and to within 3% by cine image averaging based on >3s of cine duration. We implemented the cine approach on the PET/CT scanners and acquired 216 patient data sets. 68% of patients had breathing artifacts in their clinical PET/CT and the artifacts were removed/reduced in all corresponding ACT PET/CT. PET/CT quantification for lesions <50 cm3 and

  20. SU-E-J-120: Comparing 4D CT Computed Ventilation to Lung Function Measured with Hyperpolarized Xenon-129 MRI

    SciTech Connect

    Neal, B; Chen, Q

    2015-06-15

    Purpose: To correlate ventilation parameters computed from 4D CT to ventilation, profusion, and gas exchange measured with hyperpolarized Xenon-129 MRI for a set of lung cancer patients. Methods: Hyperpolarized Xe-129 MRI lung scans were acquired for lung cancer patients, before and after radiation therapy, measuring ventilation, perfusion, and gas exchange. In the standard clinical workflow, these patients also received 4D CT scans before treatment. Ventilation was computed from 4D CT using deformable image registration (DIR). All phases of the 4D CT scan were registered using a B-spline deformable registration. Ventilation at the voxel level was then computed for each phase based on a Jacobian volume expansion metric, yielding phase sorted ventilation images. Ventilation based upon 4D CT and Xe-129 MRI were co-registered, allowing qualitative visual comparison and qualitative comparison via the Pearson correlation coefficient. Results: Analysis shows a weak correlation between hyperpolarized Xe-129 MRI and 4D CT DIR ventilation, with a Pearson correlation coefficient of 0.17 to 0.22. Further work will refine the DIR parameters to optimize the correlation. The weak correlation could be due to the limitations of 4D CT, registration algorithms, or the Xe-129 MRI imaging. Continued development will refine parameters to optimize correlation. Conclusion: Current analysis yields a minimal correlation between 4D CT DIR and Xe-129 MRI ventilation. Funding provided by the 2014 George Amorino Pilot Grant in Radiation Oncology at the University of Virginia.

  1. Clinical Utility of 4D FDG-PET/CT Scans in Radiation Treatment Planning

    SciTech Connect

    Aristophanous, Michalis; Sher, David J.; Allen, Aaron M.; Larson, Elysia; Chen, Aileen B.

    2012-01-01

    Purpose: The potential role of four-dimensional (4D) positron emission tomography (PET)/computed tomography (CT) in radiation treatment planning, relative to standard three-dimensional (3D) PET/CT, was examined. Methods and Materials: Ten patients with non-small-cell lung cancer had sequential 3D and 4D [{sup 18}F]fluorodeoxyglucose PET/CT scans in the treatment position prior to radiation therapy. The gross tumor volume and involved lymph nodes were contoured on the PET scan by use of three different techniques: manual contouring by an experienced radiation oncologist using a predetermined protocol; a technique with a constant threshold of standardized uptake value (SUV) greater than 2.5; and an automatic segmentation technique. For each technique, the tumor volume was defined on the 3D scan (VOL3D) and on the 4D scan (VOL4D) by combining the volume defined on each of the five breathing phases individually. The range of tumor motion and the location of each lesion were also recorded, and their influence on the differences observed between VOL3D and VOL4D was investigated. Results: We identified and analyzed 22 distinct lesions, including 9 primary tumors and 13 mediastinal lymph nodes. Mean VOL4D was larger than mean VOL3D with all three techniques, and the difference was statistically significant (p < 0.01). The range of tumor motion and the location of the tumor affected the magnitude of the difference. For one case, all three tumor definition techniques identified volume of moderate uptake of approximately 1 mL in the hilar region on the 4D scan (SUV maximum, 3.3) but not on the 3D scan (SUV maximum, 2.3). Conclusions: In comparison to 3D PET, 4D PET may better define the full physiologic extent of moving tumors and improve radiation treatment planning for lung tumors. In addition, reduction of blurring from free-breathing images may reveal additional information regarding regional disease.

  2. Non-local means resolution enhancement of lung 4D-CT data.

    PubMed

    Zhang, Yu; Wu, Guorong; Yap, Pew-Thian; Feng, Qianjin; Lian, Jun; Chen, Wufan; Shen, Dinggang

    2012-01-01

    Image resolution in 4D-CT is a crucial bottleneck that needs to be overcome for improved dose planning in radiotherapy for lung cancer. In this paper, we propose a novel patch-based algorithm to enhance the image quality of 4D-CT data. Our premise is that anatomical information missing in one phase can be recovered from complementary information embedded in other phases. We employ a patch-based mechanism to propagate information across phases for reconstruction of intermediate slices in the axial direction, where resolution is normally the lowest. Specifically, structurally-matching and spatially-nearby patches are combined for reconstruction of each patch. For greater sensitivity to anatomical nuances, we further employ a quad-tree technique to adaptively partition each slice of the image in each phase for more fine-grained refinement. Our evaluation based on a public 4D-CT lung data indicates that our algorithm gives very promising results with significantly enhanced image structures.

  3. Interactive annotation of textures in thoracic CT scans

    NASA Astrophysics Data System (ADS)

    Kockelkorn, Thessa T. J. P.; de Jong, Pim A.; Gietema, Hester A.; Grutters, Jan C.; Prokop, Mathias; van Ginneken, Bram

    2010-03-01

    This study describes a system for interactive annotation of thoracic CT scans. Lung volumes in these scans are segmented and subdivided into roughly spherical volumes of interest (VOIs) with homogeneous texture using a clustering procedure. For each 3D VOI, 72 features are calculated. The observer inspects the scan to determine which textures are present and annotates, with mouse clicks, several VOIs of each texture. Based on these annotations, a k-nearest-neighbor classifier is trained, which classifies all remaining VOIs in the scan. The algorithm then presents a slice with suggested annotations to the user, in which the user can correct mistakes. The classifier is retrained, taking into account these new annotations, and the user is presented another slice for correction. This process continues until at least 50% of all lung voxels in the scan have been classified. The remaining VOIs are classified automatically. In this way, the entire lung volume is annotated. The system has been applied to scans of patients with usual and non-specific interstitial pneumonia. The results of interactive annotation are compared to a setup in which the user annotates all predefined VOIs manually. The interactive system is 3.7 times as fast as complete manual annotation of VOIs and differences between the methods are similar to interobserver variability. This is a first step towards precise volumetric quantitation of texture patterns in thoracic CT in clinical research and in clinical practice.

  4. Improving the Diagnostic Specificity of CT for Early Detection of Lung Cancer: 4D CT-Based Pulmonary Nodule Elastometry

    DTIC Science & Technology

    2015-10-01

    observers manually delineated the MPN on the opposite respiratory phase using our treatment planning software, Eclipse V11 (Varian Medical Systems , Inc...results in a static image of the scanned anatomy, 4D CT incorporates also the temporal changes of the anatomy caused by respiratory motion, yielding...with the pressure sensing belt around its chest that provided the respiratory signal to the scanner. Figure 2 shows a typical respiratory trace

  5. 4D cone-beam CT reconstruction using multi-organ meshes for sliding motion modeling

    NASA Astrophysics Data System (ADS)

    Zhong, Zichun; Gu, Xuejun; Mao, Weihua; Wang, Jing

    2016-02-01

    A simultaneous motion estimation and image reconstruction (SMEIR) strategy was proposed for 4D cone-beam CT (4D-CBCT) reconstruction and showed excellent results in both phantom and lung cancer patient studies. In the original SMEIR algorithm, the deformation vector field (DVF) was defined on voxel grid and estimated by enforcing a global smoothness regularization term on the motion fields. The objective of this work is to improve the computation efficiency and motion estimation accuracy of SMEIR for 4D-CBCT through developing a multi-organ meshing model. Feature-based adaptive meshes were generated to reduce the number of unknowns in the DVF estimation and accurately capture the organ shapes and motion. Additionally, the discontinuity in the motion fields between different organs during respiration was explicitly considered in the multi-organ mesh model. This will help with the accurate visualization and motion estimation of the tumor on the organ boundaries in 4D-CBCT. To further improve the computational efficiency, a GPU-based parallel implementation was designed. The performance of the proposed algorithm was evaluated on a synthetic sliding motion phantom, a 4D NCAT phantom, and four lung cancer patients. The proposed multi-organ mesh based strategy outperformed the conventional Feldkamp-Davis-Kress, iterative total variation minimization, original SMEIR and single meshing method based on both qualitative and quantitative evaluations.

  6. 4D cone-beam CT reconstruction using multi-organ meshes for sliding motion modeling

    PubMed Central

    Zhong, Zichun; Gu, Xuejun; Mao, Weihua; Wang, Jing

    2016-01-01

    A simultaneous motion estimation and image reconstruction (SMEIR) strategy was proposed for 4D cone-beam CT (4D-CBCT) reconstruction and showed excellent results in both phantom and lung cancer patient studies. In the original SMEIR algorithm, the deformation vector field (DVF) was defined on voxel grid and estimated by enforcing a global smoothness regularization term on the motion fields. The objective of this work is to improve the computation efficiency and motion estimation accuracy of SMEIR for 4D-CBCT through developing a multi-organ meshing model. Feature-based adaptive meshes were generated to reduce the number of unknowns in the DVF estimation and accurately capture the organ shapes and motion. Additionally, the discontinuity in the motion fields between different organs during respiration was explicitly considered in the multi-organ mesh model. This will help with the accurate visualization and motion estimation of the tumor on the organ boundaries in 4D-CBCT. To further improve the computational efficiency, a GPU-based parallel implementation was designed. The performance of the proposed algorithm was evaluated on a synthetic sliding motion phantom, a 4D NCAT phantom, and four lung cancer patients. The proposed multi-organ mesh based strategy outperformed the conventional Feldkamp–Davis–Kress, iterative total variation minimization, original SMEIR and single meshing method based on both qualitative and quantitative evaluations. PMID:26758496

  7. 4D micro-CT for cardiac and perfusion applications with view under sampling

    NASA Astrophysics Data System (ADS)

    Badea, Cristian T.; Johnston, Samuel M.; Qi, Yi; Johnson, G. Allan

    2011-06-01

    Micro-CT is commonly used in preclinical studies to provide anatomical information. There is growing interest in obtaining functional measurements from 4D micro-CT. We report here strategies for 4D micro-CT with a focus on two applications: (i) cardiac imaging based on retrospective gating and (ii) pulmonary perfusion using multiple contrast injections/rotations paradigm. A dual source micro-CT system is used for image acquisition with a sampling rate of 20 projections per second. The cardiac micro-CT protocol involves the use of a liposomal blood pool contrast agent. Fast scanning of free breathing mice is achieved using retrospective gating. The ECG and respiratory signals are used to sort projections into ten cardiac phases. The pulmonary perfusion protocol uses a conventional contrast agent (Isovue 370) delivered by a micro-injector in four injections separated by 2 min intervals to allow for clearance. Each injection is synchronized with the rotation of the animal, and each of the four rotations is started with an angular offset of 22.5 from the starting angle of the previous rotation. Both cardiac and perfusion protocols result in an irregular angular distribution of projections that causes significant streaking artifacts in reconstructions when using traditional filtered backprojection (FBP) algorithms. The reconstruction involves the use of the point spread function of the micro-CT system for each time point, and the analysis of the distribution of the reconstructed data in the Fourier domain. This enables us to correct for angular inconsistencies via deconvolution and identify regions where data is missing. The missing regions are filled with data from a high quality but temporally averaged prior image reconstructed with all available projections. Simulations indicate that deconvolution successfully removes the streaking artifacts while preserving temporal information. 4D cardiac micro-CT in a mouse was performed with adequate image quality at isotropic

  8. Reconstruction of 4D-CT from a Single Free-Breathing 3D-CT by Spatial-Temporal Image Registration

    PubMed Central

    Wu, Guorong; Wang, Qian; Lian, Jun; Shen, Dinggang

    2011-01-01

    In the radiation therapy of lung cancer, a free-breathing 3D-CT image is usually acquired in the treatment day for image-guided patient setup, by registering with the free-breathing 3D-CT image acquired in the planning day. In this way, the optimal dose plan computed in the planning day can be transferred onto the treatment day for cancer radiotherapy. However, patient setup based on the simple registration of the free-breathing 3D-CT images of the planning and the treatment days may mislead the radiotherapy, since the free-breathing 3D-CT is actually the mixed-phase image, with different slices often acquired from different respiratory phases. Moreover, a 4D-CT that is generally acquired in the planning day for improvement of dose planning is often ignored for guiding patient setup in the treatment day. To overcome these limitations, we present a novel two-step method to reconstruct the 4D-CT from a single free-breathing 3D-CT of the treatment day, by utilizing the 4D-CT model built in the planning day. Specifically, in the first step, we proposed a new spatial-temporal registration algorithm to align all phase images of the 4D-CT acquired in the planning day, for building a 4D-CT model with temporal correspondences established among all respiratory phases. In the second step, we first determine the optimal phase for each slice of the free-breathing (mixed-phase) 3D-CT of the treatment day by comparing with the 4D-CT of the planning day and thus obtain a sequence of partial 3D-CT images for the treatment day, each with only the incomplete image information in certain slices; and then we reconstruct a complete 4D-CT for the treatment day by warping the 4D-CT of the planning day (with complete information) to the sequence of partial 3D-CT images of the treatment day, under the guidance of the 4D-CT model built in the planning day. We have comprehensively evaluated our 4D-CT model building algorithm on a public lung image database, achieving the best registration

  9. A comparison between amplitude sorting and phase-angle sorting using external respiratory measurement for 4D CT

    SciTech Connect

    Lu Wei; Parikh, Parag J.; Hubenschmidt, James P.; Bradley, Jeffrey D.; Low, Daniel A.

    2006-08-15

    Respiratory motion can cause significant dose delivery errors in conformal radiation therapy for thoracic and upper abdominal tumors. Four-dimensional computed tomography (4D CT) has been proposed to provide the image data necessary to model tumor motion and consequently reduce these errors. The purpose of this work was to compare 4D CT reconstruction methods using amplitude sorting and phase angle sorting. A 16-slice CT scanner was operated in cine mode to acquire 25 scans consecutively at each couch position through the thorax. The patient underwent synchronized external respiratory measurements. The scans were sorted into 12 phases based, respectively, on the amplitude and direction (inhalation or exhalation) or on the phase angle (0-360 deg.) of the external respiratory signal. With the assumption that lung motion is largely proportional to the measured respiratory amplitude, the variation in amplitude corresponds to the variation in motion for each phase. A smaller variation in amplitude would associate with an improved reconstructed image. Air content, defined as the amount of air within the lungs, bronchi, and trachea in a 16-slice CT segment and used by our group as a surrogate for internal motion, was correlated to the respiratory amplitude and phase angle throughout the lungs. For the 35 patients who underwent quiet breathing, images (similar to those used for treatment planning) and animations (used to display respiratory motion) generated using amplitude sorting displayed fewer reconstruction artifacts than those generated using phase angle sorting. The variations in respiratory amplitude were significantly smaller (P<0.001) with amplitude sorting than those with phase angle sorting. The subdivision of the breathing cycle into more (finer) phases improved the consistency in respiratory amplitude for amplitude sorting, but not for phase angle sorting. For 33 of the 35 patients, the air content showed significantly improved (P<0.001) correlation with the

  10. SU-C-9A-06: The Impact of CT Image Used for Attenuation Correction in 4D-PET

    SciTech Connect

    Cui, Y; Bowsher, J; Yan, S; Cai, J; Das, S; Yin, F

    2014-06-01

    Purpose: To evaluate the appropriateness of using 3D non-gated CT image for attenuation correction (AC) in a 4D-PET (gated PET) imaging protocol used in radiotherapy treatment planning simulation. Methods: The 4D-PET imaging protocol in a Siemens PET/CT simulator (Biograph mCT, Siemens Medical Solutions, Hoffman Estates, IL) was evaluated. CIRS Dynamic Thorax Phantom (CIRS Inc., Norfolk, VA) with a moving glass sphere (8 mL) in the middle of its thorax portion was used in the experiments. The glass was filled with {sup 18}F-FDG and was in a longitudinal motion derived from a real patient breathing pattern. Varian RPM system (Varian Medical Systems, Palo Alto, CA) was used for respiratory gating. Both phase-gating and amplitude-gating methods were tested. The clinical imaging protocol was modified to use three different CT images for AC in 4D-PET reconstruction: first is to use a single-phase CT image to mimic actual clinical protocol (single-CT-PET); second is to use the average intensity projection CT (AveIP-CT) derived from 4D-CT scanning (AveIP-CT-PET); third is to use 4D-CT image to do the phase-matched AC (phase-matching- PET). Maximum SUV (SUVmax) and volume of the moving target (glass sphere) with threshold of 40% SUVmax were calculated for comparison between 4D-PET images derived with different AC methods. Results: The SUVmax varied 7.3%±6.9% over the breathing cycle in single-CT-PET, compared to 2.5%±2.8% in AveIP-CT-PET and 1.3%±1.2% in phasematching PET. The SUVmax in single-CT-PET differed by up to 15% from those in phase-matching-PET. The target volumes measured from single- CT-PET images also presented variations up to 10% among different phases of 4D PET in both phase-gating and amplitude-gating experiments. Conclusion: Attenuation correction using non-gated CT in 4D-PET imaging is not optimal process for quantitative analysis. Clinical 4D-PET imaging protocols should consider phase-matched 4D-CT image if available to achieve better accuracy.

  11. A 4D CT digital phantom of an individual human brain for perfusion analysis

    PubMed Central

    Brune, Christoph; van Ginneken, Bram; Prokop, Mathias

    2016-01-01

    Brain perfusion is of key importance to assess brain function. Modern CT scanners can acquire perfusion maps of the cerebral parenchyma in vivo at submillimeter resolution. These perfusion maps give insights into the hemodynamics of the cerebral parenchyma and are critical for example for treatment decisions in acute stroke. However, the relations between acquisition parameters, tissue attenuation curves, and perfusion values are still poorly understood and cannot be unraveled by studies involving humans because of ethical concerns. We present a 4D CT digital phantom specific for an individual human brain to analyze these relations in a bottom-up fashion. Validation of the signal and noise components was based on 1,000 phantom simulations of 20 patient imaging data. This framework was applied to quantitatively assess the relation between radiation dose and perfusion values, and to quantify the signal-to-noise ratios of penumbra regions with decreasing sizes in white and gray matter. This is the first 4D CT digital phantom that enables to address clinical questions without having to expose the patient to additional radiation dose. PMID:27917312

  12. Technical evaluation of different respiratory monitoring systems used for 4D CT acquisition under free breathing.

    PubMed

    Heinz, Christian; Reiner, Michael; Belka, Claus; Walter, Franziska; Söhn, Matthias

    2015-03-08

    Respiratory monitoring systems are required to supply CT scanners with information on the patient's breathing during the acquisition of a respiration-correlated computer tomography (RCCT), also referred to as 4D CT. The information a respiratory monitoring system has to provide to the CT scanner depends on the specific scanner. The purpose of this study is to compare two different respiratory monitoring systems (Anzai Respiratory Gating System; C-RAD Sentinel) with respect to their applicability in combination with an Aquilion Large Bore CT scanner from Toshiba. The scanner used in our clinic does not make use of the full time dependent breathing signal, but only single trigger pulses indicating the beginning of a new breathing cycle. Hence the attached respiratory monitoring system is expected to deliver accurate online trigger pulse for each breathing cycle. The accuracy of the trigger pulses sent to the CT scanner has to be ensured by the selected respiratory monitoring system. Since a trigger pulse (output signal) of a respiratory monitoring system is a function of the measured breathing signal (input signal), the typical clinical range of the input signal is estimated for both examined respiratory monitoring systems. Both systems are analyzed based on the following parameters: time resolution, signal amplitude, noise, signal-to-noise ratio (SNR), signal linearity, trigger compatibility, and clinical examples. The Anzai system shows a better SNR (≥ 28 dB) than the Sentinel system (≥ 14.6 dB). In terms of compatibility with the cycle-based image sorting algorithm of the Toshiba CT scanner, the Anzai system benefits from the possibility to generate cycle-based triggers, whereas the Sentinel system is only able to generate amplitude-based triggers. In clinical practice, the combination of a Toshiba CT scanner and the Anzai system will provide better results due to the compatibility of the image sorting and trigger release methods.

  13. Assessment of a quantitative metric for 4D CT artifact evaluation by observer consensus.

    PubMed

    Castillo, Sarah J; Castillo, Richard; Balter, Peter; Pan, Tinsu; Ibbott, Geoffrey; Hobbs, Brian; Yuan, Ying; Guerrero, Thomas

    2014-05-08

    The benefits of four-dimensional computed tomography (4D CT) are limited by the presence of artifacts that remain difficult to quantify. A correlation-based metric previously proposed for ciné 4D CT artifact identification was further validated as an independent artifact evaluator by using a novel qualitative assessment featuring a group of observers reaching a consensus decision on artifact location and magnitude. The consensus group evaluated ten ciné 4D CT scans for artifacts over each breathing phase of coronal lung views assuming one artifact per couch location. Each artifact was assigned a magnitude score of 1-5, 1 indicating lowest severity and 5 indicating highest severity. Consensus group results served as the ground truth for assessment of the correlation metric. The ten patients were split into two cohorts; cohort 1 generated an artifact identification threshold derived from receiver operating characteristic analysis using the Youden Index, while cohort 2 generated sensitivity and specificity values from application of the artifact threshold. The Pearson correlation coefficient was calculated between the correlation metric values and the consensus group scores for both cohorts. The average sensitivity and specificity values found with application of the artifact threshold were 0.703 and 0.476, respectively. The correlation coefficients of artifact magnitudes for cohort 1 and 2 were 0.80 and 0.61, respectively, (p < 0.001 for both); these correlation coefficients included a few scans with only two of the five possible magnitude scores. Artifact incidence was associated with breathing phase (p < 0.002), with presentation less likely near maximum exhale. Overall, the correlation metric allowed accurate and automated artifact identification. The consensus group evaluation resulted in efficient qualitative scoring, reduced interobserver variation, and provided consistent identification of artifact location and magnitudes.

  14. 4D-Imaging of the Lung: Reproducibility of Lesion Size and Displacement on Helical CT, MRI, and Cone Beam CT in a Ventilated Ex Vivo System

    SciTech Connect

    Biederer, Juergen Dinkel, Julien; Remmert, Gregor; Jetter, Siri; Nill, Simeon; Moser, Torsten; Bendl, Rolf; Thierfelder, Carsten; Fabel, Michael; Oelfke, Uwe; Bock, Michael; Plathow, Christian; Bolte, Hendrik; Welzel, Thomas; Hoffmann, Beata; Hartmann, Guenter; Schlegel, Wolfgang; Debus, Juergen; Heller, Martin

    2009-03-01

    Purpose: Four-dimensional (4D) imaging is a key to motion-adapted radiotherapy of lung tumors. We evaluated in a ventilated ex vivo system how size and displacement of artificial pulmonary nodules are reproduced with helical 4D-CT, 4D-MRI, and linac-integrated cone beam CT (CBCT). Methods and Materials: Four porcine lungs with 18 agarose nodules (mean diameters 1.3-1.9 cm), were ventilated inside a chest phantom at 8/min and subject to 4D-CT (collimation 24 x 1.2 mm, pitch 0.1, slice/increment 24x10{sup 2}/1.5/0.8 mm, pitch 0.1, temporal resolution 0.5 s), 4D-MRI (echo-shared dynamic three-dimensional-flash; repetition/echo time 2.13/0.72 ms, voxel size 2.7 x 2.7 x 4.0 mm, temporal resolution 1.4 s) and linac-integrated 4D-CBCT (720 projections, 3-min rotation, temporal resolution {approx}1 s). Static CT without respiration served as control. Three observers recorded lesion size (RECIST-diameters x/y/z) and axial displacement. Interobserver- and interphase-variation coefficients (IO/IP VC) of measurements indicated reproducibility. Results: Mean x/y/z lesion diameters in cm were equal on static and dynamic CT (1.88/1.87; 1.30/1.39; 1.71/1.73; p > 0.05), but appeared larger on MRI and CBCT (2.06/1.95 [p < 0.05 vs. CT]; 1.47/1.28 [MRI vs. CT/CBCT p < 0.05]; 1.86/1.83 [CT vs. CBCT p < 0.05]). Interobserver-VC for lesion sizes were 2.54-4.47% (CT), 2.29-4.48% (4D-CT); 5.44-6.22% (MRI) and 4.86-6.97% (CBCT). Interphase-VC for lesion sizes ranged from 2.28% (4D-CT) to 10.0% (CBCT). Mean displacement in cm decreased from static CT (1.65) to 4D-CT (1.40), CBCT (1.23) and MRI (1.16). Conclusions: Lesion sizes are exactly reproduced with 4D-CT but overestimated on 4D-MRI and CBCT with a larger variability due to limited temporal and spatial resolution. All 4D-modalities underestimate lesion displacement.

  15. Dependence of ventilation image derived from 4D CT on deformable image registration and ventilation algorithms.

    PubMed

    Latifi, Kujtim; Forster, Kenneth M; Hoffe, Sarah E; Dilling, Thomas J; van Elmpt, Wouter; Dekker, Andre; Zhang, Geoffrey G

    2013-07-08

    Ventilation imaging using 4D CT is a convenient and low-cost functional imaging methodology which might be of value in radiotherapy treatment planning to spare functional lung volumes. Deformable image registration (DIR) is needed to calculate ventilation imaging from 4D CT. This study investigates the dependence of calculated ventilation on DIR methods and ventilation algorithms. DIR of the normal end expiration and normal end inspiration phases of the 4D CT images was used to correlate the voxels between the two respiratory phases. Three different DIR algorithms, optical flow (OF), diffeomorphic demons (DD), and diffeomorphic morphons (DM) were retrospectively applied to ten esophagus and ten lung cancer cases with 4D CT image sets that encompassed the entire lung volume. The three ventilation extraction methods were used based on either the Jacobian, the change in volume of the voxel, or directly calculated from Hounsfield units. The ventilation calculation algorithms used are the Jacobian, ΔV, and HU method. They were compared using the Dice similarity coefficient (DSC) index and Bland-Altman plots. Dependence of ventilation images on the DIR was greater for the ΔV and the Jacobian methods than for the HU method. The DSC index for 20% of low-ventilation volume for ΔV was 0.33 ± 0.03 (1 SD) between OF and DM, 0.44 ± 0.05 between OF and DD, and 0.51 ± 0.04 between DM and DD. The similarity comparisons for Jacobian were 0.32 ± 0.03, 0.44 ± 0.05, and 0.51 ± 0.04, respectively, and for HU they were 0.53 ± 0.03, 0.56 ± 0.03, and 0.76 ± 0.04, respectively. Dependence of extracted ventilation on the ventilation algorithm used showed good agreement between the ΔV and Jacobian methods, but differed significantly for the HU method. DSC index for using OF as DIR was 0.86 ± 0.01 between ΔV and Jacobian, 0.28 ± 0.04 between ΔV and HU, and 0.28 ± 0.04 between Jacobian and HU, respectively. When using DM or DD as DIR, similar values were obtained when

  16. Segmentation of the thoracic aorta in noncontrast cardiac CT images.

    PubMed

    Avila-Montes, Olga C; Kurkure, Uday; Nakazato, Ryo; Berman, Daniel S; Dey, Damini; Kakadiaris, Ioannis A

    2013-09-01

    Studies have shown that aortic calcification is associated with cardiovascular disease. In this study, a method for localization, centerline extraction, and segmentation of the thoracic aorta in noncontrast cardiac-computed tomography (CT) images, toward the detection of aortic calcification, is presented. The localization of the right coronary artery ostium slice is formulated as a regression problem whose input variables are obtained from simple intensity features computed from a pyramid representation of the slice. The localization, centerline extraction, and segmentation of the aorta are formulated as optimal path detection problems. Dynamic programming is applied in the Hough space for localizing key center points in the aorta which guide the centerline tracing using a fast marching-based minimal path extraction framework. The input volume is then resampled into a stack of 2-D cross-sectional planes orthogonal to the obtained centerline. Dynamic programming is again applied for the segmentation of the aorta in each slice of the resampled volume. The obtained segmentation is finally mapped back to its original volume space. The performance of the proposed method was assessed on cardiac noncontrast CT scans and promising results were obtained.

  17. Reconstruction of 4D-CT data sets acquired during free breathing for the analysis of respiratory motion

    NASA Astrophysics Data System (ADS)

    Ehrhardt, Jan; Werner, Rene; Frenzel, Thorsten; Säring, Dennis; Lu, Wei; Low, Daniel; Handels, Heinz

    2006-03-01

    Respiratory motion is a significant source of error in radiotherapy treatment planning. 4D-CT data sets can be useful to measure the impact of organ motion caused by breathing. But modern CT scanners can only scan a limited region of the body simultaneously and patients have to be scanned in segments consisting of multiple slices. For studying free breathing motion multislice CT scans can be collected simultaneously with digital spirometry over several breathing cycles. The 4D data set is assembled by sorting the free breathing multislice CT scans according to the couch position and the tidal volume. But artifacts can occur because there are no data segments for exactly the same tidal volume and all couch positions. We present an optical flow based method for the reconstruction of 4D-CT data sets from multislice CT scans, which are collected simultaneously with digital spirometry. The optical flow between the scans is estimated by a non-linear registration method. The calculated velocity field is used to reconstruct a 4D-CT data set by interpolating data at user-defined tidal volumes. By this technique, artifacts can be reduced significantly. The reconstructed 4D-CT data sets are used for studying inner organ motion during the respiratory cycle. The procedures described were applied to reconstruct 4D-CT data sets for four tumour patients who have been scanned during free breathing. The reconstructed 4D data sets were used to quantify organ displacements and to visualize the abdominothoracic organ motion.

  18. Reference geometry-based detection of (4D-)CT motion artifacts: a feasibility study

    NASA Astrophysics Data System (ADS)

    Werner, René; Gauer, Tobias

    2015-03-01

    Respiration-correlated computed tomography (4D or 3D+t CT) can be considered as standard of care in radiation therapy treatment planning for lung and liver lesions. The decision about an application of motion management devices and the estimation of patient-specific motion effects on the dose distribution relies on precise motion assessment in the planning 4D CT data { which is impeded in case of CT motion artifacts. The development of image-based/post-processing approaches to reduce motion artifacts would benefit from precise detection and localization of the artifacts. Simple slice-by-slice comparison of intensity values and threshold-based analysis of related metrics suffer from- depending on the threshold- high false-positive or -negative rates. In this work, we propose exploiting prior knowledge about `ideal' (= artifact free) reference geometries to stabilize metric-based artifact detection by transferring (multi-)atlas-based concepts to this specific task. Two variants are introduced and evaluated: (S1) analysis and comparison of warped atlas data obtained by repeated non-linear atlas-to-patient registration with different levels of regularization; (S2) direct analysis of vector field properties (divergence, curl magnitude) of the atlas-to-patient transformation. Feasibility of approaches (S1) and (S2) is evaluated by motion-phantom data and intra-subject experiments (four patients) as well as - adopting a multi-atlas strategy- inter-subject investigations (twelve patients involved). It is demonstrated that especially sorting/double structure artifacts can be precisely detected and localized by (S1). In contrast, (S2) suffers from high false positive rates.

  19. Spatial-temporal total variation regularization (STTVR) for 4D-CT reconstruction

    NASA Astrophysics Data System (ADS)

    Wu, Haibo; Maier, Andreas; Fahrig, Rebecca; Hornegger, Joachim

    2012-03-01

    Four dimensional computed tomography (4D-CT) is very important for treatment planning in thorax or abdomen area, e.g. for guiding radiation therapy planning. The respiratory motion makes the reconstruction problem illposed. Recently, compressed sensing theory was introduced. It uses sparsity as a prior to solve the problem and improves image quality considerably. However, the images at each phase are reconstructed individually. The correlations between neighboring phases are not considered in the reconstruction process. In this paper, we propose the spatial-temporal total variation regularization (STTVR) method which not only employs the sparsity in the spatial domain but also in the temporal domain. The algorithm is validated with XCAT thorax phantom. The Euclidean norm of the reconstructed image and ground truth is calculated for evaluation. The results indicate that our method improves the reconstruction quality by more than 50% compared to standard ART.

  20. 4D-CT lung motion estimation with deformable registration: quantification of motion nonlinearity and hysteresis.

    PubMed

    Boldea, Vlad; Sharp, Gregory C; Jiang, Steve B; Sarrut, David

    2008-03-01

    In this article, our goal is twofold. First, we propose and compare two methods which process deformable registration to estimate patient specific lung and tumor displacements and deformation during free breathing from four-dimensional computed tomography (4D-CT) data. Second, we propose techniques to quantify the physiological parameters of motion nonlinearity and hysteresis. A Fréchet distance-based criterion is introduced to measure the motion hysteresis. Experiments were conducted with 4D-CT data of five patients treated in radiotherapy for non-small cell lung cancer. The accuracy of deformation fields assessed against expert-selected landmarks was found to be within image voxel tolerance. The second method gave slightly better results in terms of accuracy and consistency, although the differences were not statistically significant between the two methods. Lung motion nonlinearity and hysteresis are patient specific, and vary across regions within the lung during respiration. For all patients, motion between end-exhale and end-inhale was well approximated with a straight line trajectory for the majority of lung points. Hysteresis was found to be globally correlated with trajectory length. The main limitation to the proposed method is that intensity-based deformable registration is dependent on image quality and image resolution. Another limitation is the absence of gold standard which makes the validation of the computed motion difficult. However, the proposed tools provide patient specific motion information which, in radiotherapy for example, can ease the definition of precise internal margins. In the future, the integration of physiological information from multiple patients could help to create a general lung atlas with different clinical applications.

  1. Comparison of an alternative and existing binning methods to reduce the acquisition duration of 4D PET/CT

    SciTech Connect

    Didierlaurent, David Ribes, Sophie; Caselles, Olivier; Jaudet, Cyril; Dierickx, Lawrence O.; Zerdoud, Slimane; Brillouet, Severine; Weits, Kathleen; Batatia, Hadj; Courbon, Frédéric

    2014-11-01

    Purpose: Respiratory motion is a source of artifacts that reduce image quality in PET. Four dimensional (4D) PET/CT is one approach to overcome this problem. Existing techniques to limiting the effects of respiratory motions are based on prospective phase binning which requires a long acquisition duration (15–25 min). This time is uncomfortable for the patients and limits the clinical exploitation of 4D PET/CT. In this work, the authors evaluated an existing method and an alternative retrospective binning method to reduce the acquisition duration of 4D PET/CT. Methods: The authors studied an existing mixed-amplitude binning (MAB) method and an alternative binning method by mixed-phases (MPhB). Before implementing MPhB, they analyzed the regularity of the breathing patterns in patients. They studied the breathing signal drift and missing CT slices that could be challenging for implementing MAB. They compared the performance of MAB and MPhB with current binning methods to measure the maximum uptake, internal volume, and maximal range of tumor motion. Results: MPhB can be implemented depending on an optimal phase (in average, the exhalation peak phase −4.1% of the entire breathing cycle duration). Signal drift of patients was in average 35% relative to the breathing amplitude. Even after correcting this drift, MAB was feasible in 4D CT for only 64% of patients. No significant differences appeared between the different binning methods to measure the maximum uptake, internal volume, and maximal range of tumor motion. The authors also determined the inaccuracies of MAB and MPhB to measure the maximum amplitude of tumor motion with three bins (less than 3 mm for movement inferior to 12 mm, up to 6.4 mm for a 21 mm movement). Conclusions: The authors proposed an alternative binning method by mixed-phase binning that halves the acquisition duration of 4D PET/CT. Mixed-amplitude binning was challenging because of signal drift and missing CT slices. They showed that more

  2. TU-G-BRA-02: Can We Extract Lung Function Directly From 4D-CT Without Deformable Image Registration?

    SciTech Connect

    Kipritidis, J; Woodruff, H; Counter, W; Keall, P; Hofman, M; Siva, S; Callahan, J; Le Roux, P; Hardcastle, N

    2015-06-15

    Purpose: Dynamic CT ventilation imaging (CT-VI) visualizes air volume changes in the lung by evaluating breathing-induced lung motion using deformable image registration (DIR). Dynamic CT-VI could enable functionally adaptive lung cancer radiation therapy, but its sensitivity to DIR parameters poses challenges for validation. We hypothesize that a direct metric using CT parameters derived from Hounsfield units (HU) alone can provide similar ventilation images without DIR. We compare the accuracy of Direct and Dynamic CT-VIs versus positron emission tomography (PET) images of inhaled {sup 68}Ga-labelled nanoparticles (‘Galligas’). Methods: 25 patients with lung cancer underwent Galligas 4D-PET/CT scans prior to radiation therapy. For each patient we produced three CT- VIs. (i) Our novel method, Direct CT-VI, models blood-gas exchange as the product of air and tissue density at each lung voxel based on time-averaged 4D-CT HU values. Dynamic CT-VIs were produced by evaluating: (ii) regional HU changes, and (iii) regional volume changes between the exhale and inhale 4D-CT phase images using a validated B-spline DIR method. We assessed the accuracy of each CT-VI by computing the voxel-wise Spearman correlation with free-breathing Galligas PET, and also performed a visual analysis. Results: Surprisingly, Direct CT-VIs exhibited better global correlation with Galligas PET than either of the dynamic CT-VIs. The (mean ± SD) correlations were (0.55 ± 0.16), (0.41 ± 0.22) and (0.29 ± 0.27) for Direct, Dynamic HU-based and Dynamic volume-based CT-VIs respectively. Visual comparison of Direct CT-VI to PET demonstrated similarity for emphysema defects and ventral-to-dorsal gradients, but inability to identify decreased ventilation distal to tumor-obstruction. Conclusion: Our data supports the hypothesis that Direct CT-VIs are as accurate as Dynamic CT-VIs in terms of global correlation with Galligas PET. Visual analysis, however, demonstrated that different CT

  3. Variations in tumor size and position due to irregular breathing in 4D-CT: A simulation study

    SciTech Connect

    Sarker, Joyatee; Chu, Alan; Mui, Kit; Wolfgang, John A.; Hirsch, Ariel E.; Chen, George T. Y.; Sharp, Gregory C.

    2010-03-15

    Purpose: To estimate the position and volume errors in 4D-CT caused by irregular breathing. Methods: A virtual 4D-CT scanner was designed to reproduce axial mode scans with retrospective resorting. This virtual scanner creates an artificial spherical tumor based on the specifications of the user, and recreates images that might be produced by a 4D-CT scanner using a patient breathing waveform. 155 respiratory waveforms of patients were used to test the variability of 4D-CT scans. Each breathing waveform was normalized and scaled to 1, 2, and 3 cm peak-to-peak motion, and artificial tumors with 2 and 4 cm radius were simulated for each scaled waveform. The center of mass and volume of resorted 4D-CT images were calculated and compared to the expected values of center of mass and volume for the artificial tumor. Intrasubject variability was investigated by running the virtual scanner over different subintervals of each patient's breathing waveform. Results: The average error in the center of mass location of an artificial tumor was less than 2 mm standard deviation for 2 cm motion. The corresponding average error in volume was less than 4%. In the worst-case scenarios, a center of mass error of 1.0 cm standard deviation and volume errors of 30%-60% at inhale were found. Systematic errors were observed in a subset of patients due to irregular breathing, and these errors were more pronounced when the tumor volume is smaller. Conclusions: Irregular breathing during 4D-CT simulation causes systematic errors in volume and center of mass measurements. These errors are small but depend on the tumor size, motion amplitude, and degree of breathing irregularity.

  4. Effect of heart rate on CT angiography using the enhanced cardiac model of the 4D NCAT

    NASA Astrophysics Data System (ADS)

    Segars, W. P.; Taguchi, K.; Fung, G. S. K.; Fishman, E. K.; Tsui, B. M. W.

    2006-03-01

    We investigate the effect of heart rate on the quality and artifact generation in coronary artery images obtained using multi-slice computed tomography (MSCT) with the purpose of finding the optimal time resolution for data acquisition. To perform the study, we used the 4D NCAT phantom, a computer model of the normal human anatomy and cardiac and respiratory motions developed in our laboratory. Although capable of being far more realistic, the 4D NCAT cardiac model was originally designed for low-resolution imaging research, and lacked the anatomical detail to be applicable to high-resolution CT. In this work, we updated the cardiac model to include a more detailed anatomy and physiology based on high-resolution clinical gated MSCT data. To demonstrate its utility in high-resolution dynamic CT imaging research, the enhanced 4D NCAT was then used in a pilot simulation study to investigate the effect of heart rate on CT angiography. The 4D NCAT was used to simulate patients with different heart rates (60-120 beats/minute) and with various cardiac plaques of known size and location within the coronary arteries. For each simulated patient, MSCT projection data was generated with data acquisition windows ranging from 100 to 250 ms centered within the quiet phase (mid-diastole) of the heart using an analytical CT projection algorithm. CT images were reconstructed from the projection data, and the contrast of the plaques was then measured to assess the effect of heart rate and to determine the optimal time resolution required for each case. The 4D NCAT phantom with its realistic model for the cardiac motion was found to provide a valuable tool from which to optimize CT cardiac applications. Our results indicate the importance of optimizing the time resolution with regard to heart rate and plaque location for improved CT images at a reduced patient dose.

  5. Automatic landmark generation for deformable image registration evaluation for 4D CT images of lung

    NASA Astrophysics Data System (ADS)

    Vickress, J.; Battista, J.; Barnett, R.; Morgan, J.; Yartsev, S.

    2016-10-01

    Deformable image registration (DIR) has become a common tool in medical imaging across both diagnostic and treatment specialties, but the methods used offer varying levels of accuracy. Evaluation of DIR is commonly performed using manually selected landmarks, which is subjective, tedious and time consuming. We propose a semi-automated method that saves time and provides accuracy comparable to manual selection. Three landmarking methods including manual (with two independent observers), scale invariant feature transform (SIFT), and SIFT with manual editing (SIFT-M) were tested on 10 thoracic 4DCT image studies corresponding to the 0% and 50% phases of respiration. Results of each method were evaluated against a gold standard (GS) landmark set comparing both mean and proximal landmark displacements. The proximal method compares the local deformation magnitude between a test landmark pair and the closest GS pair. Statistical analysis was done using an intra class correlation (ICC) between test and GS displacement values. The creation time per landmark pair was 22, 34, 2.3, and 4.3 s for observers 1 and 2, SIFT, and SIFT-M methods respectively. Across 20 lungs from the 10 CT studies, the ICC values between the GS and observer 1 and 2, SIFT, and SIFT-M methods were 0.85, 0.85, 0.84, and 0.82 for mean lung deformation, and 0.97, 0.98, 0.91, and 0.96 for proximal landmark deformation, respectively. SIFT and SIFT-M methods have an accuracy that is comparable to manual methods when tested against a GS landmark set while saving 90% of the time. The number and distribution of landmarks significantly affected the analysis as manifested by the different results for mean deformation and proximal landmark deformation methods. Automatic landmark methods offer a promising alternative to manual landmarking, if the quantity, quality and distribution of landmarks can be optimized for the intended application.

  6. Algorithm of pulmonary emphysema extraction using thoracic 3D CT images

    NASA Astrophysics Data System (ADS)

    Saita, Shinsuke; Kubo, Mitsuru; Kawata, Yoshiki; Niki, Noboru; Nakano, Yasutaka; Ohmatsu, Hironobu; Tominaga, Keigo; Eguchi, Kenji; Moriyama, Noriyuki

    2007-03-01

    Recently, due to aging and smoking, emphysema patients are increasing. The restoration of alveolus which was destroyed by emphysema is not possible, thus early detection of emphysema is desired. We describe a quantitative algorithm for extracting emphysematous lesions and quantitatively evaluate their distribution patterns using low dose thoracic 3-D CT images. The algorithm identified lung anatomies, and extracted low attenuation area (LAA) as emphysematous lesion candidates. Applying the algorithm to thoracic 3-D CT images and then by follow-up 3-D CT images, we demonstrate its potential effectiveness to assist radiologists and physicians to quantitatively evaluate the emphysematous lesions distribution and their evolution in time interval changes.

  7. Vessel Enhancement and Segmentation of 4D CT Lung Image Using Stick Tensor Voting

    NASA Astrophysics Data System (ADS)

    Cong, Tan; Hao, Yang; Jingli, Shi; Xuan, Yang

    2016-12-01

    Vessel enhancement and segmentation plays a significant role in medical image analysis. This paper proposes a novel vessel enhancement and segmentation method for 4D CT lung image using stick tensor voting algorithm, which focuses on addressing the vessel distortion issue of vessel enhancement diffusion (VED) method. Furthermore, the enhanced results are easily segmented using level-set segmentation. In our method, firstly, vessels are filtered using Frangi's filter to reduce intrapulmonary noises and extract rough blood vessels. Secondly, stick tensor voting algorithm is employed to estimate the correct direction along the vessel. Then the estimated direction along the vessel is used as the anisotropic diffusion direction of vessel in VED algorithm, which makes the intensity diffusion of points locating at the vessel wall be consistent with the directions of vessels and enhance the tubular features of vessels. Finally, vessels can be extracted from the enhanced image by applying level-set segmentation method. A number of experiments results show that our method outperforms traditional VED method in vessel enhancement and results in satisfied segmented vessels.

  8. OVERVIEW, PRACTICAL TIPS AND POTENTIAL PITFALLS OF USING AUTOMATIC EXPOSURE CONTROL IN CT: SIEMENS CARE DOSE 4D.

    PubMed

    Söderberg, Marcus

    2016-06-01

    Today, computed tomography (CT) systems routinely use automatic exposure control (AEC), which modulates the tube current. However, for optimal use, there are several aspects of an AEC system that need to be considered. The purpose of this study was to provide an overview of the Siemens CARE Dose 4D AEC system, discuss practical tips and demonstrate potential pitfalls. Two adult anthropomorphic phantoms were examined using two different Siemens CT systems. When optimising the CT radiation dose and image quality, the projection angle of the localiser, patient centring, protocol selection, scanning direction and the use of protective devices requires special attention.

  9. Spatial correspondence of 4D CT ventilation and SPECT pulmonary perfusion defects in patients with malignant airway stenosis

    NASA Astrophysics Data System (ADS)

    Castillo, Richard; Castillo, Edward; McCurdy, Matthew; Gomez, Daniel R.; Block, Alec M.; Bergsma, Derek; Joy, Sarah; Guerrero, Thomas

    2012-04-01

    To determine the spatial overlap agreement between four-dimensional computed tomography (4D CT) ventilation and single photon emission computed tomography (SPECT) perfusion hypo-functioning pulmonary defect regions in a patient population with malignant airway stenosis. Treatment planning 4D CT images were obtained retrospectively for ten lung cancer patients with radiographically demonstrated airway obstruction due to gross tumor volume. Each patient also received a SPECT perfusion study within one week of the planning 4D CT, and prior to the initiation of treatment. Deformable image registration was used to map corresponding lung tissue elements between the extreme component phase images, from which quantitative three-dimensional (3D) images representing the local pulmonary specific ventilation were constructed. Semi-automated segmentation of the percentile perfusion distribution was performed to identify regional defects distal to the known obstructing lesion. Semi-automated segmentation was similarly performed by multiple observers to delineate corresponding defect regions depicted on 4D CT ventilation. Normalized Dice similarity coefficient (NDSC) indices were determined for each observer between SPECT perfusion and 4D CT ventilation defect regions to assess spatial overlap agreement. Tidal volumes determined from 4D CT ventilation were evaluated versus measurements obtained from lung parenchyma segmentation. Linear regression resulted in a linear fit with slope = 1.01 (R2 = 0.99). Respective values for the average DSC, NDSC1 mm and NDSC2 mm for all cases and multiple observers were 0.78, 0.88 and 0.99, indicating that, on average, spatial overlap agreement between ventilation and perfusion defect regions was comparable to the threshold for agreement within 1-2 mm uncertainty. Corresponding coefficients of variation for all metrics were similarly in the range: 0.10%-19%. This study is the first to quantitatively assess 3D spatial overlap agreement between

  10. Validation of the 4D NCAT simulation tools for use in high-resolution x-ray CT research

    NASA Astrophysics Data System (ADS)

    Segars, W. P.; Mahesh, Mahadevappa; Beck, T.; Frey, E. C.; Tsui, B. M. W.

    2005-04-01

    We validate the computer-based simulation tools developed in our laboratory for use in high-resolution CT research. The 4D NURBS-based cardiac-torso (NCAT) phantom was developed to provide a realistic and flexible model of the human anatomy and physiology. Unlike current phantoms in CT, the 4D NCAT has the advantage, due to its design, that its organ shapes can be changed to realistically model anatomical variations and patient motion. To efficiently simulate high-resolution CT images, we developed a unique analytic projection algorithm (including scatter and quantum noise) to accurately calculate projections directly from the surface definition of the phantom given parameters defining the CT scanner and geometry. The projection data are reconstructed into CT images using algorithms developed in our laboratory. The 4D NCAT phantom contains a level of detail that is close to impossible to produce in a physical test object. We, therefore, validate our CT simulation tools and methods through a series of direct comparisons with data obtained experimentally using existing, simple physical phantoms at different doses and using different x-ray energy spectra. In each case, the first-order simulations were found to produce comparable results (<12%). We reason that since the simulations produced equivalent results using simple test objects, they should be able to do the same in more anatomically realistic conditions. We conclude that, with the ability to provide realistic simulated CT image data close to that from actual patients, the simulation tools developed in this work will have applications in a broad range of CT imaging research.

  11. A novel CT-FFR method for the coronary artery based on 4D-CT image analysis and structural and fluid analysis

    NASA Astrophysics Data System (ADS)

    Hirohata, K.; Kano, A.; Goryu, A.; Ooga, J.; Hongo, T.; Higashi, S.; Fujisawa, Y.; Wakai, S.; Arakita, K.; Ikeda, Y.; Kaminaga, S.; Ko, B. S.; Seneviratne, S. K.

    2015-03-01

    Non invasive fractional flow reserve derived from CT coronary angiography (CT-FFR) has to date been typically performed using the principles of fluid analysis in which a lumped parameter coronary vascular bed model is assigned to represent the impedance of the downstream coronary vascular networks absent in the computational domain for each coronary outlet. This approach may have a number of limitations. It may not account for the impact of the myocardial contraction and relaxation during the cardiac cycle, patient-specific boundary conditions for coronary artery outlets and vessel stiffness. We have developed a novel approach based on 4D-CT image tracking (registration) and structural and fluid analysis, to address these issues. In our approach, we analyzed the deformation variation of vessels and the volume variation of vessels, primarily from 70% to 100% of cardiac phase, to better define boundary conditions and stiffness of vessels. We used a statistical estimation method based on a hierarchical Bayes model to integrate 4D-CT measurements and structural and fluid analysis data. Under these analysis conditions, we performed structural and fluid analysis to determine pressure, flow rate and CT-FFR. The consistency of this method has been verified by a comparison of 4D-CTFFR analysis results derived from five clinical 4D-CT datasets with invasive measurements of FFR. Additionally, phantom experiments of flexible tubes with/without stenosis using pulsating pumps, flow sensors and pressure sensors were performed. Our results show that the proposed 4D-CT-FFR analysis method has the potential to accurately estimate the effect of coronary artery stenosis on blood flow.

  12. Can nontriggered thoracic CT be used for coronary artery calcium scoring? A phantom study

    SciTech Connect

    Xie, Xueqian; Greuter, Marcel J. W.; Groen, Jaap M.; Bock, Geertruida H. de; Oudkerk, Matthijs; Jong, Pim A. de; Vliegenthart, Rozemarijn

    2013-08-15

    Purpose: Coronary artery calcium score, traditionally based on electrocardiography (ECG)-triggered computed tomography (CT), predicts cardiovascular risk. However, nontriggered CT is extensively utilized. The study-purpose is to evaluate the in vitro agreement in coronary calcium score between nontriggered thoracic CT and ECG-triggered cardiac CT.Methods: Three artificial coronary arteries containing calcifications of different densities (high, medium, and low), and sizes (large, medium, and small), were studied in a moving cardiac phantom. Two 64-detector CT systems were used. The phantom moved at 0–90 mm/s in nontriggered low-dose CT as index test, and at 0–30 mm/s in ECG-triggered CT as reference. Differences in calcium scores between nontriggered and ECG-triggered CT were analyzed by t-test and 95% confidence interval. The sensitivity to detect calcification was calculated as the percentage of positive calcium scores.Results: Overall, calcium scores in nontriggered CT were not significantly different to those in ECG-triggered CT (p > 0.05). Calcium scores in nontriggered CT were within the 95% confidence interval of calcium scores in ECG-triggered CT, except predominantly at higher velocities (≥50 mm/s) for the high-density and large-size calcifications. The sensitivity for a nonzero calcium score was 100% for large calcifications, but 46%± 11% for small calcifications in nontriggered CT.Conclusions: When performing multiple measurements, good agreement in positive calcium scores is found between nontriggered thoracic and ECG-triggered cardiac CT. Agreement decreases with increasing coronary velocity. From this phantom study, it can be concluded that a high calcium score can be detected by nontriggered CT, and thus, that nontriggered CT likely can identify individuals at high risk of cardiovascular disease. On the other hand, a zero calcium score in nontriggered CT does not reliably exclude coronary calcification.

  13. Management of CT screen-detected lung nodule: the thoracic surgeon perspective

    PubMed Central

    Al-Ayoubi, Adnan M.

    2016-01-01

    Implementation of lung cancer CT screening programs will increase the incidence of pulmonary nodules and require multidisciplinary efforts for devising appropriate treatment plans. The role of the thoracic surgeon is paramount in leading the discussion and shaping the treatment strategies. Management of CT screen-detected lung nodules differ from conventional lung cancer nodules given their smaller size, varied histologies and potentially indolent growth. Here we present a brief overview of the thoracic surgeon’s perspective on the clinical evaluation, diagnostic tests and surgical approach to these nodules in the setting of a comprehensive lung cancer screening program. PMID:27195274

  14. Multi-organ segmentation from multi-phase abdominal CT via 4D graphs using enhancement, shape and location optimization.

    PubMed

    Linguraru, Marius George; Pura, John A; Chowdhury, Ananda S; Summers, Ronald M

    2010-01-01

    The interpretation of medical images benefits from anatomical and physiological priors to optimize computer-aided diagnosis (CAD) applications. Diagnosis also relies on the comprehensive analysis of multiple organs and quantitative measures of soft tissue. An automated method optimized for medical image data is presented for the simultaneous segmentation of four abdominal organs from 4D CT data using graph cuts. Contrast-enhanced CT scans were obtained at two phases: non-contrast and portal venous. Intra-patient data were spatially normalized by non-linear registration. Then 4D erosion using population historic information of contrast-enhanced liver, spleen, and kidneys was applied to multi-phase data to initialize the 4D graph and adapt to patient specific data. CT enhancement information and constraints on shape, from Parzen windows, and location, from a probabilistic atlas, were input into a new formulation of a 4D graph. Comparative results demonstrate the effects of appearance and enhancement, and shape and location on organ segmentation.

  15. SU-D-207-04: GPU-Based 4D Cone-Beam CT Reconstruction Using Adaptive Meshing Method

    SciTech Connect

    Zhong, Z; Gu, X; Iyengar, P; Mao, W; Wang, J; Guo, X

    2015-06-15

    Purpose: Due to the limited number of projections at each phase, the image quality of a four-dimensional cone-beam CT (4D-CBCT) is often degraded, which decreases the accuracy of subsequent motion modeling. One of the promising methods is the simultaneous motion estimation and image reconstruction (SMEIR) approach. The objective of this work is to enhance the computational speed of the SMEIR algorithm using adaptive feature-based tetrahedral meshing and GPU-based parallelization. Methods: The first step is to generate the tetrahedral mesh based on the features of a reference phase 4D-CBCT, so that the deformation can be well captured and accurately diffused from the mesh vertices to voxels of the image volume. After the mesh generation, the updated motion model and other phases of 4D-CBCT can be obtained by matching the 4D-CBCT projection images at each phase with the corresponding forward projections of the deformed reference phase of 4D-CBCT. The entire process of this 4D-CBCT reconstruction method is implemented on GPU, resulting in significantly increasing the computational efficiency due to its tremendous parallel computing ability. Results: A 4D XCAT digital phantom was used to test the proposed mesh-based image reconstruction algorithm. The image Result shows both bone structures and inside of the lung are well-preserved and the tumor position can be well captured. Compared to the previous voxel-based CPU implementation of SMEIR, the proposed method is about 157 times faster for reconstructing a 10 -phase 4D-CBCT with dimension 256×256×150. Conclusion: The GPU-based parallel 4D CBCT reconstruction method uses the feature-based mesh for estimating motion model and demonstrates equivalent image Result with previous voxel-based SMEIR approach, with significantly improved computational speed.

  16. TH-E-17A-04: Geometric Validation of K-Space Self-Gated 4D-MRI Vs. 4D-CT Using A Respiratory Motion Phantom

    SciTech Connect

    Yue, Y; Fan, Z; Yang, W; Pang, J; McKenzie, E; Deng, Z; Tuli, R; Sandler, H; Li, D; Fraass, B

    2014-06-15

    Purpose: 4D-CT is often limited by motion artifacts, low temporal resolution, and poor phase-based target definition. We recently developed a novel k-space self-gated 4D-MRI technique with high spatial and temporal resolution. The goal here is to geometrically validate 4D-MRI using a MRI-CT compatible respiratory motion phantom and comparison to 4D-CT. Methods: 4D-MRI was acquired using 3T spoiled gradient echo-based 3D projection sequences. Respiratory phases were resolved using self-gated k-space lines as the motion surrogate. Images were reconstructed into 10 temporal bins with 1.56×1.56×1.56mm3. A MRI-CT compatible phantom was designed with a 23mm diameter ball target filled with highconcentration gadolinium(Gd) gel embedded in a 35×40×63mm3 plastic box stabilized with low-concentration Gd gel. The whole phantom was driven by an air pump. Human respiratory motion was mimicked using the controller from a commercial dynamic phantom (RSD). Four breathing settings (rates/depths: 10s/20mm, 6s/15mm, 4s/10mm, 3s/7mm) were scanned with 4D-MRI and 4D-CT (slice thickness 1.25mm). Motion ground-truth was obtained from input signals and real-time video recordings. Reconstructed images were imported into Eclipse(Varian) for target contouring. Volumes and target positions were compared with ground-truth. Initial human study was investigated on a liver patient. Results: 4D-MRI and 4D-CT scans for the different breathing cycles were reconstructed with 10 phases. Target volume in each phase was measured for both 4D-CT and 4D-MRI. Volume percentage difference for the 6.37ml target ranged from 6.67±5.33 to 11.63±5.57 for 4D-CT and from 1.47±0.52 to 2.12±1.60 for 4D-MRI. The Mann-Whitney U-test shows the 4D-MRI is significantly superior to 4D-CT (p=0.021) for phase-based target definition. Centroid motion error ranges were 1.35–1.25mm (4D-CT), and 0.31–0.12mm (4D-MRI). Conclusion: The k-space self-gated 4D-MRI we recently developed can accurately determine phase

  17. Evaluation of the ΔV 4D CT ventilation calculation method using in vivo xenon CT ventilation data and comparison to other methods.

    PubMed

    Zhang, Geoffrey G; Latifi, Kujtim; Du, Kaifang; Reinhardt, Joseph M; Christensen, Gary E; Ding, Kai; Feygelman, Vladimir; Moros, Eduardo G

    2016-03-08

    Ventilation distribution calculation using 4D CT has shown promising potential in several clinical applications. This study evaluated the direct geometric ventilation calculation method, namely the ΔV method, with xenon-enhanced CT (XeCT) ventilation data from four sheep, and compared it with two other published meth-ods, the Jacobian and the Hounsfield unit (HU) methods. Spearman correlation coefficient (SCC) and Dice similarity coefficient (DSC) were used for the evaluation and comparison. The average SCC with one standard deviation was 0.44 ± 0.13 with a range between 0.29 and 0.61 between the XeCT and ΔV ventilation distributions. The average DSC value for lower 30% ventilation volumes between the XeCT and ΔV ventilation distributions was 0.55 ± 0.07 with a range between 0.48 and 0.63. Ventilation difference introduced by deformable image registration errors improved with smoothing. In conclusion, ventilation distributions generated using ΔV-4D CT and deformable image registration are in reasonably agreement with the in vivo XeCT measured ventilation distribution.

  18. Tumor and normal tissue motion in the thorax during respiration: Analysis of volumetric and positional variations using 4D CT

    SciTech Connect

    Weiss, Elisabeth . E-mail: eweiss@mcvh-vcu.edu; Wijesooriya, Krishni; Dill, S. Vaughn; Keall, Paul J.

    2007-01-01

    Purpose: To investigate temporospatial variations of tumor and normal tissue during respiration in lung cancer patients. Methods and Materials: In 14 patients, gross tumor volume (GTV) and normal tissue structures were manually contoured on four-dimensional computed tomography (4D-CT) scans. Structures were evaluated for volume changes, centroid (center of mass) motion, and phase dependence of variations relative to inspiration. Only volumetrically complete structures were used for analysis (lung in 2, heart in 8, all other structures in >10 patients). Results: During respiration, the magnitude of contoured volumes varied up to 62.5% for GTVs, 25.5% for lungs, and 12.6% for hearts. The range of maximum three-dimensional centroid movement for individual patients was 1.3-24.0 mm for GTV, 2.4-7.9 mm for heart, 5.2-12.0 mm for lungs, 0.3-5.5 mm for skin markers, 2.9-10.0 mm for trachea, and 6.6-21.7 mm for diaphragm. During respiration, the centroid positions of normal structures varied relative to the centroid position of the respective GTV by 1.5-8.1 mm for heart, 2.9-9.3 mm for lungs, 1.2-9.2 mm for skin markers, 0.9-7.1 mm for trachea, and 2.7-16.4 mm for diaphragm. Conclusion: Using 4D-CT, volumetric changes, positional alterations as well as changes in the position of contoured structures relative to the GTV were observed with large variations between individual patients. Although the interpretation of 4D-CT data has considerable uncertainty because of 4D-CT artifacts, observer variations, and the limited acquisition time, the findings might have a significant impact on treatment planning.

  19. TH-E-17A-01: Internal Respiratory Surrogate for 4D CT Using Fourier Transform and Anatomical Features

    SciTech Connect

    Hui, C; Suh, Y; Robertson, D; Pan, T; Das, P; Crane, C; Beddar, S

    2014-06-15

    Purpose: To develop a novel algorithm to generate internal respiratory signals for sorting of four-dimensional (4D) computed tomography (CT) images. Methods: The proposed algorithm extracted multiple time resolved features as potential respiratory signals. These features were taken from the 4D CT images and its Fourier transformed space. Several low-frequency locations in the Fourier space and selected anatomical features from the images were used as potential respiratory signals. A clustering algorithm was then used to search for the group of appropriate potential respiratory signals. The chosen signals were then normalized and averaged to form the final internal respiratory signal. Performance of the algorithm was tested in 50 4D CT data sets and results were compared with external signals from the real-time position management (RPM) system. Results: In almost all cases, the proposed algorithm generated internal respiratory signals that visibly matched the external respiratory signals from the RPM system. On average, the end inspiration times calculated by the proposed algorithm were within 0.1 s of those given by the RPM system. Less than 3% of the calculated end inspiration times were more than one time frame away from those given by the RPM system. In 3 out of the 50 cases, the proposed algorithm generated internal respiratory signals that were significantly smoother than the RPM signals. In these cases, images sorted using the internal respiratory signals showed fewer artifacts in locations corresponding to the discrepancy in the internal and external respiratory signals. Conclusion: We developed a robust algorithm that generates internal respiratory signals from 4D CT images. In some cases, it even showed the potential to outperform the RPM system. The proposed algorithm is completely automatic and generally takes less than 2 min to process. It can be easily implemented into the clinic and can potentially replace the use of external surrogates.

  20. Comparison of two respiration monitoring systems for 4D imaging with a Siemens CT using a new dynamic breathing phantom.

    PubMed

    Vásquez, A C; Runz, A; Echner, G; Sroka-Perez, G; Karger, C P

    2012-05-07

    Four-dimensional computed tomography (4D-CT) requires breathing information from the patient, and for this, several systems are available. Testing of these systems, under realistic conditions, requires a phantom with a moving target and an expandable outer contour. An anthropomorphic phantom was developed to simulate patient breathing as well as lung tumor motion. Using the phantom, an optical camera system (GateCT) and a pressure sensor (AZ-733V) were simultaneously operated, and 4D-CTs were reconstructed with a Siemens CT using the provided local-amplitude-based sorting algorithm. The comparison of the tumor trajectories of both systems revealed discrepancies up to 9.7 mm. Breathing signal differences, such as baseline drift, temporal resolution and noise level were shown not to be the reason for this. Instead, the variability of the sampling interval and the accuracy of the sampling rate value written on the header of the GateCT-signal file were identified as the cause. Interpolation to regular sampling intervals and correction of the sampling rate to the actual value removed the observed discrepancies. Consistently, the introduction of sampling interval variability and inaccurate sampling rate values into the header of the AZ-733V file distorted the tumor trajectory for this system. These results underline the importance of testing new equipment thoroughly, especially if components of different manufacturers are combined.

  1. Applying an animal model to quantify the uncertainties of an image-based 4D-CT algorithm

    NASA Astrophysics Data System (ADS)

    Pierce, Greg; Wang, Kevin; Battista, Jerry; Lee, Ting-Yim

    2012-06-01

    The purpose of this paper is to use an animal model to quantify the spatial displacement uncertainties and test the fundamental assumptions of an image-based 4D-CT algorithm in vivo. Six female Landrace cross pigs were ventilated and imaged using a 64-slice CT scanner (GE Healthcare) operating in axial cine mode. The breathing amplitude pattern of the pigs was varied by periodically crimping the ventilator gas return tube during the image acquisition. The image data were used to determine the displacement uncertainties that result from matching CT images at the same respiratory phase using normalized cross correlation (NCC) as the matching criteria. Additionally, the ability to match the respiratory phase of a 4.0 cm subvolume of the thorax to a reference subvolume using only a single overlapping 2D slice from the two subvolumes was tested by varying the location of the overlapping matching image within the subvolume and examining the effect this had on the displacement relative to the reference volume. The displacement uncertainty resulting from matching two respiratory images using NCC ranged from 0.54 ± 0.10 mm per match to 0.32 ± 0.16 mm per match in the lung of the animal. The uncertainty was found to propagate in quadrature, increasing with number of NCC matches performed. In comparison, the minimum displacement achievable if two respiratory images were matched perfectly in phase ranged from 0.77 ± 0.06 to 0.93 ± 0.06 mm in the lung. The assumption that subvolumes from separate cine scan could be matched by matching a single overlapping 2D image between to subvolumes was validated. An in vivo animal model was developed to test an image-based 4D-CT algorithm. The uncertainties associated with using NCC to match the respiratory phase of two images were quantified and the assumption that a 4.0 cm 3D subvolume can by matched in respiratory phase by matching a single 2D image from the 3D subvolume was validated. The work in this paper shows the image-based 4D-CT

  2. A hybrid approach for fusing 4D-MRI temporal information with 3D-CT for the study of lung and lung tumor motion

    SciTech Connect

    Yang, Y. X.; Van Reeth, E.; Poh, C. L.; Teo, S.-K.; Tan, C. H.; Tham, I. W. K.

    2015-08-15

    Purpose: Accurate visualization of lung motion is important in many clinical applications, such as radiotherapy of lung cancer. Advancement in imaging modalities [e.g., computed tomography (CT) and MRI] has allowed dynamic imaging of lung and lung tumor motion. However, each imaging modality has its advantages and disadvantages. The study presented in this paper aims at generating synthetic 4D-CT dataset for lung cancer patients by combining both continuous three-dimensional (3D) motion captured by 4D-MRI and the high spatial resolution captured by CT using the authors’ proposed approach. Methods: A novel hybrid approach based on deformable image registration (DIR) and finite element method simulation was developed to fuse a static 3D-CT volume (acquired under breath-hold) and the 3D motion information extracted from 4D-MRI dataset, creating a synthetic 4D-CT dataset. Results: The study focuses on imaging of lung and lung tumor. Comparing the synthetic 4D-CT dataset with the acquired 4D-CT dataset of six lung cancer patients based on 420 landmarks, accurate results (average error <2 mm) were achieved using the authors’ proposed approach. Their hybrid approach achieved a 40% error reduction (based on landmarks assessment) over using only DIR techniques. Conclusions: The synthetic 4D-CT dataset generated has high spatial resolution, has excellent lung details, and is able to show movement of lung and lung tumor over multiple breathing cycles.

  3. CT thoracic duct lymphography in cats by popliteal lymph node iohexol injection.

    PubMed

    Lee, Namsoon; Won, Sungjun; Choi, Mihyun; Kim, Junyoung; Yi, Kangjae; Chang, Dongwoo; Choi, Mincheol; Yoon, Junghee

    2012-01-01

    Three different doses (1.0, 1.5, and 2.0 ml) of iohexol (300 mgl/ml) were injected percutaneously into the popliteal lymph node of eight adult cats under ultrasound guidance. Serial transverse CT images of five regions of interest (L3, T13, T8, T4, and T1 level) were performed at 2-min intervals, and the attenuation in Hounsfield Units (HU) of the lymphatic vessels was measured for determination of the optimal dose of iohexol and CT scan parameters. The optimal dose was 1.5 ml and helical CT acquisition is recommended to be performed as soon as possible after iohexol injection. In helical scans, the thoracic duct was characterized by variable branch numbers that formed a single trunk and entered the venous system at variable levels. CT lymphography using this protocol was performed in a cat with chylothorax. The thoracic duct was tortuous and focally dilated, and leakage of contrast medium was observed. Percutaneous CT lymphography using ultrasound-guided administration of iohexol into the popliteal lymph node appears reliable for delineation of the thoracic duct in cats.

  4. Assessing Cardiac Injury in Mice With Dual Energy-MicroCT, 4D-MicroCT, and MicroSPECT Imaging After Partial Heart Irradiation

    SciTech Connect

    Lee, Chang-Lung; Min, Hooney; Befera, Nicholas; Clark, Darin; Qi, Yi; Das, Shiva; Johnson, G. Allan; Badea, Cristian T.; Kirsch, David G.

    2014-03-01

    Purpose: To develop a mouse model of cardiac injury after partial heart irradiation (PHI) and to test whether dual energy (DE)-microCT and 4-dimensional (4D)-microCT can be used to assess cardiac injury after PHI to complement myocardial perfusion imaging using micro-single photon emission computed tomography (SPECT). Methods and Materials: To study cardiac injury from tangent field irradiation in mice, we used a small-field biological irradiator to deliver a single dose of 12 Gy x-rays to approximately one-third of the left ventricle (LV) of Tie2Cre; p53{sup FL/+} and Tie2Cre; p53{sup FL/−} mice, where 1 or both alleles of p53 are deleted in endothelial cells. Four and 8 weeks after irradiation, mice were injected with gold and iodinated nanoparticle-based contrast agents, and imaged with DE-microCT and 4D-microCT to evaluate myocardial vascular permeability and cardiac function, respectively. Additionally, the same mice were imaged with microSPECT to assess myocardial perfusion. Results: After PHI with tangent fields, DE-microCT scans showed a time-dependent increase in accumulation of gold nanoparticles (AuNp) in the myocardium of Tie2Cre; p53{sup FL/−} mice. In Tie2Cre; p53{sup FL/−} mice, extravasation of AuNp was observed within the irradiated LV, whereas in the myocardium of Tie2Cre; p53{sup FL/+} mice, AuNp were restricted to blood vessels. In addition, data from DE-microCT and microSPECT showed a linear correlation (R{sup 2} = 0.97) between the fraction of the LV that accumulated AuNp and the fraction of LV with a perfusion defect. Furthermore, 4D-microCT scans demonstrated that PHI caused a markedly decreased ejection fraction, and higher end-diastolic and end-systolic volumes, to develop in Tie2Cre; p53{sup FL/−} mice, which were associated with compensatory cardiac hypertrophy of the heart that was not irradiated. Conclusions: Our results show that DE-microCT and 4D-microCT with nanoparticle-based contrast agents are novel imaging approaches

  5. SU-E-J-154: Image Quality Assessment of Contrast-Enhanced 4D-CT for Pancreatic Adenocarcinoma in Radiotherapy Simulation

    SciTech Connect

    Choi, W; Xue, M; Patel, K; Regine, W; Wang, J; D’Souza, W; Lu, W; Kang, M; Klahr, P

    2015-06-15

    Purpose: This study presents quantitative and qualitative assessment of the image qualities in contrast-enhanced (CE) 3D-CT, 4D-CT and CE 4D-CT to identify feasibility for replacing the clinical standard simulation with a single CE 4D-CT for pancreatic adenocarcinoma (PDA) in radiotherapy simulation. Methods: Ten PDA patients were enrolled and underwent three CT scans: a clinical standard pair of CE 3D-CT immediately followed by a 4D-CT, and a CE 4D-CT one week later. Physicians qualitatively evaluated the general image quality and regional vessel definitions and gave a score from 1 to 5. Next, physicians delineated the contours of the tumor (T) and the normal pancreatic parenchyma (P) on the three CTs (CE 3D-CT, 50% phase for 4D-CT and CE 4D-CT), then high density areas were automatically removed by thresholding at 500 HU and morphological operations. The pancreatic tumor contrast-to-noise ratio (CNR), signal-tonoise ratio (SNR) and conspicuity (C, absolute difference of mean enhancement levels in P and T) were computed to quantitatively assess image quality. The Wilcoxon rank sum test was used to compare these quantities. Results: In qualitative evaluations, CE 3D-CT and CE 4D-CT scored equivalently (4.4±0.4 and 4.3±0.4) and both were significantly better than 4D-CT (3.1±0.6). In quantitative evaluations, the C values were higher in CE 4D-CT (28±19 HU, p=0.19 and 0.17) than the clinical standard pair of CE 3D-CT and 4D-CT (17±12 and 16±17 HU, p=0.65). In CE 3D-CT and CE 4D-CT, mean CNR (1.8±1.4 and 1.8±1.7, p=0.94) and mean SNR (5.8±2.6 and 5.5±3.2, p=0.71) both were higher than 4D-CT (CNR: 1.1±1.3, p<0.3; SNR: 3.3±2.1, p<0.1). The absolute enhancement levels for T and P were higher in CE 4D-CT (87, 82 HU) than in CE 3D-CT (60, 56) and 4DCT (53, 70). Conclusions: The individually optimized CE 4D-CT is feasible and achieved comparable image qualities to the clinical standard simulation. This study was supported in part by Philips Healthcare.

  6. [Development of CT manifestations and anatomic studies on thoracic-abdominal junctional zone].

    PubMed

    Ye, Yilan; Deng, Wen; Yang, Zhigang

    2010-12-01

    Thoracic-abdominal junctional zone is an area from the inferior chest to superior belly. The inferior chest contains inferior pulmonary lobes, pulmonary ligament, inferior mediastinum and lower thoracic cavity,while the superior belly contains upper abdominal cavity, spatium retroperitonaeale, abdominal aorta, inferior vena cava, liver, stomach, adrenal glands, kidneys and spleen. This article is to review the CT manifestations and anatomy of diseases such as infection, trauma, hemorrhage, hernia and tumor involving this area. It could provides anatomic and pathological information for instituting clinical treatments.

  7. Internal respiratory surrogate in multislice 4D CT using a combination of Fourier transform and anatomical features

    SciTech Connect

    Hui, Cheukkai; Suh, Yelin; Robertson, Daniel; Beddar, Sam; Pan, Tinsu; Das, Prajnan; Crane, Christopher H.

    2015-07-15

    Purpose: The purpose of this study was to develop a novel algorithm to create a robust internal respiratory signal (IRS) for retrospective sorting of four-dimensional (4D) computed tomography (CT) images. Methods: The proposed algorithm combines information from the Fourier transform of the CT images and from internal anatomical features to form the IRS. The algorithm first extracts potential respiratory signals from low-frequency components in the Fourier space and selected anatomical features in the image space. A clustering algorithm then constructs groups of potential respiratory signals with similar temporal oscillation patterns. The clustered group with the largest number of similar signals is chosen to form the final IRS. To evaluate the performance of the proposed algorithm, the IRS was computed and compared with the external respiratory signal from the real-time position management (RPM) system on 80 patients. Results: In 72 (90%) of the 4D CT data sets tested, the IRS computed by the authors’ proposed algorithm matched with the RPM signal based on their normalized cross correlation. For these data sets with matching respiratory signals, the average difference between the end inspiration times (Δt{sub ins}) in the IRS and RPM signal was 0.11 s, and only 2.1% of Δt{sub ins} were more than 0.5 s apart. In the eight (10%) 4D CT data sets in which the IRS and the RPM signal did not match, the average Δt{sub ins} was 0.73 s in the nonmatching couch positions, and 35.4% of them had a Δt{sub ins} greater than 0.5 s. At couch positions in which IRS did not match the RPM signal, a correlation-based metric indicated poorer matching of neighboring couch positions in the RPM-sorted images. This implied that, when IRS did not match the RPM signal, the images sorted using the IRS showed fewer artifacts than the clinical images sorted using the RPM signal. Conclusions: The authors’ proposed algorithm can generate robust IRSs that can be used for retrospective

  8. The development of a population of 4D pediatric XCAT phantoms for CT imaging research and optimization

    NASA Astrophysics Data System (ADS)

    Norris, Hannah; Zhang, Yakun; Frush, Jack; Sturgeon, Gregory M.; Minhas, Anum; Tward, Daniel J.; Ratnanather, J. Tilak; Miller, M. I.; Frush, Donald; Samei, Ehsan; Segars, W. Paul

    2014-03-01

    With the increased use of CT examinations, the associated radiation dose has become a large concern, especially for pediatrics. Much research has focused on reducing radiation dose through new scanning and reconstruction methods. Computational phantoms provide an effective and efficient means for evaluating image quality, patient-specific dose, and organ-specific dose in CT. We previously developed a set of highly-detailed 4D reference pediatric XCAT phantoms at ages of newborn, 1, 5, 10, and 15 years with organ and tissues masses matched to ICRP Publication 89 values. We now extend this reference set to a series of 64 pediatric phantoms of a variety of ages and height and weight percentiles, representative of the public at large. High resolution PET-CT data was reviewed by a practicing experienced radiologist for anatomic regularity and was then segmented with manual and semi-automatic methods to form a target model. A Multi-Channel Large Deformation Diffeomorphic Metric Mapping (MC-LDDMM) algorithm was used to calculate the transform from the best age matching pediatric reference phantom to the patient target. The transform was used to complete the target, filling in the non-segmented structures and defining models for the cardiac and respiratory motions. The complete phantoms, consisting of thousands of structures, were then manually inspected for anatomical accuracy. 3D CT data was simulated from the phantoms to demonstrate their ability to generate realistic, patient quality imaging data. The population of pediatric phantoms developed in this work provides a vital tool to investigate dose reduction techniques in 3D and 4D pediatric CT.

  9. In-treatment 4D cone-beam CT with image-based respiratory phase recognition.

    PubMed

    Kida, Satoshi; Masutani, Yoshitaka; Yamashita, Hideomi; Imae, Toshikazu; Matsuura, Taeko; Saotome, Naoya; Ohtomo, Kuni; Nakagawa, Keiichi; Haga, Akihiro

    2012-07-01

    The use of respiration-correlated cone-beam computed tomography (4D-CBCT) appears to be crucial for implementing precise radiation therapy of lung cancer patients. The reconstruction of 4D-CBCT images requires a respiratory phase. In this paper, we propose a novel method based on an image-based phase recognition technique using normalized cross correlation (NCC). We constructed the respiratory phase by searching for a region in an adjacent projection that achieves the maximum correlation with a region in a reference projection along the cranio-caudal direction. The data on 12 lung cancer patients acquired just prior to treatment and on 3 lung cancer patients acquired during volumetric modulated arc therapy treatment were analyzed in the search for the effective area of cone-beam projection images for performing NCC with 12 combinations of registration area and segment size. The evaluation was done by a "recognition rate" defined as the ratio of the number of peak inhales detected with our method to that detected by eye (manual tracking). The average recognition rate of peak inhale with the most efficient area in the present method was 96.4%. The present method was feasible even when the diaphragm was outside the field of view. With the most efficient area, we reconstructed in-treatment 4D-CBCT by dividing the breathing signal into four phase bins; peak exhale, peak inhale, and two intermediate phases. With in-treatment 4D-CBCT images, it was possible to identify the tumor position and the tumor size in moments of inspiration and expiration, in contrast to in-treatment CBCT reconstructed with all projections.

  10. Optimizing 4D cone-beam CT acquisition protocol for external beam radiotherapy

    SciTech Connect

    Li Tianfang; Xing Lei . E-mail: lei@reyes.stanford.edu

    2007-03-15

    Purpose: Four-dimensional cone-beam computed tomography (4D-CBCT) imaging is sensitive to parameters such as gantry rotation speed, number of gantry rotations, X-ray pulse rate, and tube current, as well as a patient's breathing pattern. The aim of this study is to optimize the image acquisition on a patient-specific basis while minimizing the scan time and the radiation dose. Methods and Materials: More than 60 sets of 4D-CBCT images, each with a temporal resolution of 10 phases, were acquired using multiple-gantry rotation and slow-gantry rotation techniques. The image quality was quantified with a relative root mean-square error (RE) and correlated with various acquisition settings; specifically, varying gantry rotation speed, varying both the rotation speed and the number of rotations, and varying both the rotation speed and tube current to keep the radiation exposure constant. These experiments were repeated for three different respiratory periods. Results: With similar radiation dose, 4D-CBCT images acquired with low current and low rotation speed have better quality over images obtained with high current and high rotation speed. In general, a one-rotation low-speed scan is superior to a two-rotation double-speed scan, even though they provide the same number of projections. Furthermore, it is found that the image quality behaves monotonically with the relative speed as defined by the gantry rotation speed and the patient respiratory period. Conclusions: The RE curves established in this work can be used to predict the 4D-CBCT image quality before a scan. This allows the acquisition protocol to be optimized individually to balance the desired quality with the associated scanning time and patient radiation dose.

  11. Thoracic manifestations of Behçet disease at CT.

    PubMed

    Hiller, Nurith; Lieberman, Sivan; Chajek-Shaul, Tova; Bar-Ziv, Jacob; Shaham, Dorith

    2004-01-01

    Behçet disease is a multisystemic and chronic inflammatory disorder of unknown cause that is characterized by recurrent oral and genital ulcerations, ocular manifestations, and additional clinical manifestations in multiple organ systems. Behçet disease involving the chest can manifest as a wide spectrum of abnormalities. Although conventional chest radiography is commonly used for initial assessment, spiral computed tomography can demonstrate the entire spectrum of thoracic manifestations of Behçet disease, including abnormalities of the vessel lumen and wall, perivascular tissues, lung parenchyma, pleura, and mediastinal structures. Aneurysms of the pulmonary arteries, with or without thrombosis, are a typical manifestation of Behçet disease. Other manifestations include thrombosis, vasculitis, hemorrhage, infarction, and inflammation. Familiarity with these manifestations can be useful in the diagnosis of Behçet disease, helping to determine the cause of symptoms in patients who present with hemoptysis and guide the choice of appropriate therapy.

  12. Quantification of accuracy of the automated nonlinear image matching and anatomical labeling (ANIMAL) nonlinear registration algorithm for 4D CT images of lung.

    PubMed

    Heath, E; Collins, D L; Keall, P J; Dong, L; Seuntjens, J

    2007-11-01

    The performance of the ANIMAL (Automated Nonlinear Image Matching and Anatomical Labeling) nonlinear registration algorithm for registration of thoracic 4D CT images was investigated. The algorithm was modified to minimize the incidence of deformation vector discontinuities that occur during the registration of lung images. Registrations were performed between the inhale and exhale phases for five patients. The registration accuracy was quantified by the cross-correlation of transformed and target images and distance to agreement (DTA) measured based on anatomical landmarks and triangulated surfaces constructed from manual contours. On average, the vector DTA between transformed and target landmarks was 1.6 mm. Comparing transformed and target 3D triangulated surfaces derived from planning contours, the average target volume (GTV) center-of-mass shift was 2.0 mm and the 3D DTA was 1.6 mm. An average DTA of 1.8 mm was obtained for all planning structures. All DTA metrics were comparable to inter observer uncertainties established for landmark identification and manual contouring.

  13. Volume estimation of multi-density nodules with thoracic CT

    NASA Astrophysics Data System (ADS)

    Gavrielides, Marios A.; Li, Qin; Zeng, Rongping; Myers, Kyle J.; Sahiner, Berkman; Petrick, Nicholas

    2014-03-01

    The purpose of this work was to quantify the effect of surrounding density on the volumetric assessment of lung nodules in a phantom CT study. Eight synthetic multidensity nodules were manufactured by enclosing spherical cores in larger spheres of double the diameter and with a different uniform density. Different combinations of outer/inner diameters (20/10mm, 10/5mm) and densities (100HU/-630HU, 10HU/- 630HU, -630HU/100HU, -630HU/-10HU) were created. The nodules were placed within an anthropomorphic phantom and scanned with a 16-detector row CT scanner. Ten repeat scans were acquired using exposures of 20, 100, and 200mAs, slice collimations of 16x0.75mm and 16x1.5mm, and pitch of 1.2, and were reconstructed with varying slice thicknesses (three for each collimation) using two reconstruction filters (medium and standard). The volumes of the inner nodule cores were estimated from the reconstructed CT data using a matched-filter approach with templates modeling the characteristics of the multi-density objects. Volume estimation of the inner nodule was assessed using percent bias (PB) and the standard deviation of percent error (SPE). The true volumes of the inner nodules were measured using micro CT imaging. Results show PB values ranging from -12.4 to 2.3% and SPE values ranging from 1.8 to 12.8%. This study indicates that the volume of multi-density nodules can be measured with relatively small percent bias (on the order of +/-12% or less) when accounting for the properties of surrounding densities. These findings can provide valuable information for understanding bias and variability in clinical measurements of nodules that also include local biological changes such as inflammation and necrosis.

  14. From 3D to 4D: Integration of temporal information into CT angiography studies.

    PubMed

    Haubenreisser, Holger; Bigdeli, Amir; Meyer, Mathias; Kremer, Thomas; Riester, Thomas; Kneser, Ulrich; Schoenberg, Stefan O; Henzler, Thomas

    2015-12-01

    CT angiography is the current clinical standard for the imaging many vascular illnesses. This is traditionally done with a single arterial contrast phase. However, advances in CT technology allow for a dynamic acquisition of the contrast bolus, thus adding temporal information to the examination. The aim of this article is to highlight the clinical possibilities of dynamic CTA using 2 examples. The accuracy of the detection and quantification of stenosis in patients with peripheral arterial occlusive disease, especially in stadium III and IV, is significantly improved when performing dynamic CTA examinations. The post-interventional follow-up of examinations of EVAR benefit from dynamic information, allowing for a higher sensitivity and specificity, as well as allowing more accurate classification of potential endoleaks. The described radiation dose for these dynamic examinations is low, but this can be further optimized by using lower tube voltages. There are a multitude of applications for dynamic CTA that need to be further explored in future studies.

  15. TU-F-CAMPUS-J-03: Evaluation of a New GE Device-Less Cine 4D-CT

    SciTech Connect

    Martin, R; Pan, T; Chandler, A; Doan, D; Rowland, C

    2015-06-15

    Purpose: Standard cine 4D-CT (S-4DCT) is the cine CT scan of the thorax followed by image sorting with the respiratory signal recorded by the RPM. Although the feasibility of cine 4D-CT without RPM or device-less 4DCT (DL-4DCT) has been reported in a laboratory setting, the only commercial implementation of DL-4DCT was made recently by GE based on the measurements of the lung, body and air area and density. We report the initial results of this new DL-4DCT on its determination of gross tumor volume (GTV). Methods: 30 stereotactic body radiation therapy (SBRT) patients with NSCLC were included in the study. All patients received the S-4DCT for their treatment planning. Their cine CT data without the respiratory signal from RPM were submitted to the DL-4DCT. The DL-4DCT image quality was assessed in reference to S-4DCT. Using maximum intensity projection (MIP) images, the GTVs of the S-4DCT and DL-4DCT were compared on a subset of 9 patients whose tumors in the low density lung regions could be contoured using a region growing algorithm in MIM without contouring bias from the user. A lower threshold of −424 HU was used for all patients and other algorithm parameters were held constant for each patient. Results: The DL-4DCT was able to produce the 4DCT images on 29 out of the 30 SBRT cases. One case failed due to the enhanced calcification surrounding both the breast implants. The GTVs determined on the 9 patients with DL-4DCT were 4.2 ± 4.8% smaller than the GTVs with S-4DCT. However, this was statistically insignificant (p=0.15). The Dice similarity coefficients were 95.1 ± 1.8%. The image quality of DL-4DCT and S-4DCT was similar on the 29 cases. Conclusion: The first commercial DL-4DCT was promising in generating 4D-CT images without a respiratory monitoring device in this preliminary study of 30 patients.

  16. 4D motion modeling of the coronary arteries from CT images for robotic assisted minimally invasive surgery

    NASA Astrophysics Data System (ADS)

    Zhang, Dong Ping; Edwards, Eddie; Mei, Lin; Rueckert, Daniel

    2009-02-01

    In this paper, we present a novel approach for coronary artery motion modeling from cardiac Computed Tomography( CT) images. The aim of this work is to develop a 4D motion model of the coronaries for image guidance in robotic-assisted totally endoscopic coronary artery bypass (TECAB) surgery. To utilize the pre-operative cardiac images to guide the minimally invasive surgery, it is essential to have a 4D cardiac motion model to be registered with the stereo endoscopic images acquired intraoperatively using the da Vinci robotic system. In this paper, we are investigating the extraction of the coronary arteries and the modelling of their motion from a dynamic sequence of cardiac CT. We use a multi-scale vesselness filter to enhance vessels in the cardiac CT images. The centerlines of the arteries are extracted using a ridge traversal algorithm. Using this method the coronaries can be extracted in near real-time as only local information is used in vessel tracking. To compute the deformation of the coronaries due to cardiac motion, the motion is extracted from a dynamic sequence of cardiac CT. Each timeframe in this sequence is registered to the end-diastole timeframe of the sequence using a non-rigid registration algorithm based on free-form deformations. Once the images have been registered a dynamic motion model of the coronaries can be obtained by applying the computed free-form deformations to the extracted coronary arteries. To validate the accuracy of the motion model we compare the actual position of the coronaries in each time frame with the predicted position of the coronaries as estimated from the non-rigid registration. We expect that this motion model of coronaries can facilitate the planning of TECAB surgery, and through the registration with real-time endoscopic video images it can reduce the conversion rate from TECAB to conventional procedures.

  17. Improving the Diagnostic Specificity of CT for Early Detection of Lung Cancer: 4D CT-Based Pulmonary Nodule Elastometry

    DTIC Science & Technology

    2014-08-01

    multiple animals both with benign nodules (talc granulomas ) as well as malignant orthotopic lung tumors. Figure 2 shows respiratory-gated micro-CT...there may be little difference in elasticity between these nodule types, indicating that talc granulomas may be very stiff. As such, we have

  18. Thoracic cavity definition for 3D PET/CT analysis and visualization.

    PubMed

    Cheirsilp, Ronnarit; Bascom, Rebecca; Allen, Thomas W; Higgins, William E

    2015-07-01

    X-ray computed tomography (CT) and positron emission tomography (PET) serve as the standard imaging modalities for lung-cancer management. CT gives anatomical details on diagnostic regions of interest (ROIs), while PET gives highly specific functional information. During the lung-cancer management process, a patient receives a co-registered whole-body PET/CT scan pair and a dedicated high-resolution chest CT scan. With these data, multimodal PET/CT ROI information can be gleaned to facilitate disease management. Effective image segmentation of the thoracic cavity, however, is needed to focus attention on the central chest. We present an automatic method for thoracic cavity segmentation from 3D CT scans. We then demonstrate how the method facilitates 3D ROI localization and visualization in patient multimodal imaging studies. Our segmentation method draws upon digital topological and morphological operations, active-contour analysis, and key organ landmarks. Using a large patient database, the method showed high agreement to ground-truth regions, with a mean coverage=99.2% and leakage=0.52%. Furthermore, it enabled extremely fast computation. For PET/CT lesion analysis, the segmentation method reduced ROI search space by 97.7% for a whole-body scan, or nearly 3 times greater than that achieved by a lung mask. Despite this reduction, we achieved 100% true-positive ROI detection, while also reducing the false-positive (FP) detection rate by >5 times over that achieved with a lung mask. Finally, the method greatly improved PET/CT visualization by eliminating false PET-avid obscurations arising from the heart, bones, and liver. In particular, PET MIP views and fused PET/CT renderings depicted unprecedented clarity of the lesions and neighboring anatomical structures truly relevant to lung-cancer assessment.

  19. Thoracic Cavity Definition for 3D PET/CT Analysis and Visualization

    PubMed Central

    Cheirsilp, Ronnarit; Bascom, Rebecca; Allen, Thomas W.; Higgins, William E.

    2015-01-01

    X-ray computed tomography (CT) and positron emission tomography (PET) serve as the standard imaging modalities for lung-cancer management. CT gives anatomical detail on diagnostic regions of interest (ROIs), while PET gives highly specific functional information. During the lung-cancer management process, a patient receives a co-registered whole-body PET/CT scan pair and a dedicated high-resolution chest CT scan. With these data, multimodal PET/CT ROI information can be gleaned to facilitate disease management. Effective image segmentation of the thoracic cavity, however, is needed to focus attention on the central chest. We present an automatic method for thoracic cavity segmentation from 3D CT scans. We then demonstrate how the method facilitates 3D ROI localization and visualization in patient multimodal imaging studies. Our segmentation method draws upon digital topological and morphological operations, active-contour analysis, and key organ landmarks. Using a large patient database, the method showed high agreement to ground-truth regions, with a mean coverage = 99.2% and leakage = 0.52%. Furthermore, it enabled extremely fast computation. For PET/CT lesion analysis, the segmentation method reduced ROI search space by 97.7% for a whole-body scan, or nearly 3 times greater than that achieved by a lung mask. Despite this reduction, we achieved 100% true-positive ROI detection, while also reducing the false-positive (FP) detection rate by >5 times over that achieved with a lung mask. Finally, the method greatly improved PET/CT visualization by eliminating false PET-avid obscurations arising from the heart, bones, and liver. In particular, PET MIP views and fused PET/CT renderings depicted unprecedented clarity of the lesions and neighboring anatomical structures truly relevant to lung-cancer assessment. PMID:25957746

  20. CT-guided thoracic sympathetic blockade for palmar hyperhidrosis: Immediate results and postoperative quality of life.

    PubMed

    Guo, Jian-Guo; Fei, Yong; Huang, Bing; Yao, Ming

    2016-12-01

    The purpose of this study was to evaluate the results, complications, and degree of satisfaction among patients who underwent a CT-guided percutaneous puncture thoracic sympathetic blockade. A total of 186 patients underwent CT-guided thoracic sympathetic blockade based on case histories and a prospective pre- and postoperative questionnaire survey. The study sample was composed of 93 patients with an age range from 18 to 34years and a diagnosis with primary palmar hyperhidrosis (severe in some patients). Percutaneous puncture thoracic sympathetic blockade guided by CT was performed under local anesthesia in all patients. Heart rate (HR), non-invasive blood pressure (NIBP), arterial oxygen saturation (SPO2), perfusion index (PI), and palmar temperature (T) were monitored before and after treatment. Follow-up included a questionnaire on life quality and degree of satisfaction. Ten minutes after treatment, the SPO2, PI, and temperature all raised remarkably ([92.75±2.02]% vs. [98.85±1.09]%, [1.55±0.69]% vs. [8.60±0.94]%, [30.95±1.27]°C vs. [35.75±0.55]°C, respectively, P<0.001). The therapeutic success rate was 96.7%. No operative mortality was recorded. No complications were observed, except transient bradycardia in one patient and transient injection site pain in 25 patients. Of the 89 patients who were monitored over a period of 6-12months through follow-up interviews and questionnaires, 46% developed compensatory hyperhidrosis, 87.6% reported improvement in their quality of life. CT-guided percutaneous puncture thoracic sympathetic blockade is a safe, effective, and minimally invasive technique for the treatment of palmar hyperhidrosis. Despite the high rate of compensatory hyperhidrosis, it produces a high rate of patient satisfaction.

  1. Capillary Hemangioma of Thoracic Spinal Cord: PET/CT and MR Findings.

    PubMed

    Shen, Guohua; Su, Minggang; Zhao, Junyi; Liu, Bin; Kuang, Anren

    2017-02-13

    Capillary hemangiomas are frequently encountered superficially in the cutaneous, subcutaneous, or mucosal tissues during the childhood and early adulthood, but the occurrence of spinal intradural capillary hemangioma is relatively rare. Herein, we report a case with capillary hemangioma of the thoracic spine. MR and PET/CT features of this lesion are presented, and awareness of this entity may help differentiate it from other spinal intradural tumors.

  2. Semi-automatic classification of textures in thoracic CT scans

    NASA Astrophysics Data System (ADS)

    Kockelkorn, Thessa T. J. P.; de Jong, Pim A.; Schaefer-Prokop, Cornelia M.; Wittenberg, Rianne; Tiehuis, Audrey M.; Gietema, Hester A.; Grutters, Jan C.; Viergever, Max A.; van Ginneken, Bram

    2016-08-01

    The textural patterns in the lung parenchyma, as visible on computed tomography (CT) scans, are essential to make a correct diagnosis in interstitial lung disease. We developed one automatic and two interactive protocols for classification of normal and seven types of abnormal lung textures. Lungs were segmented and subdivided into volumes of interest (VOIs) with homogeneous texture using a clustering approach. In the automatic protocol, VOIs were classified automatically by an extra-trees classifier that was trained using annotations of VOIs from other CT scans. In the interactive protocols, an observer iteratively trained an extra-trees classifier to distinguish the different textures, by correcting mistakes the classifier makes in a slice-by-slice manner. The difference between the two interactive methods was whether or not training data from previously annotated scans was used in classification of the first slice. The protocols were compared in terms of the percentages of VOIs that observers needed to relabel. Validation experiments were carried out using software that simulated observer behavior. In the automatic classification protocol, observers needed to relabel on average 58% of the VOIs. During interactive annotation without the use of previous training data, the average percentage of relabeled VOIs decreased from 64% for the first slice to 13% for the second half of the scan. Overall, 21% of the VOIs were relabeled. When previous training data was available, the average overall percentage of VOIs requiring relabeling was 20%, decreasing from 56% in the first slice to 13% in the second half of the scan.

  3. Improving the Diagnostic Specificity of CT for Early Detection of Lung Cancer: 4D CT-Based Pulmonary Nodule Elastometry

    DTIC Science & Technology

    2014-08-01

    Discovery ST PET/CT Scanner (General Electric Medical Systems , Waukesha, WI), using the following acquisition settings: 120 KVp, 110-195 mAs, 1.25...Varian Medical Systems , Inc., Palo Alto, CA). To address inter-observer 70 variability, the MPNs delineated by the two observers were compared to...pressure are not fully understood, but are thought to involve blood-vessel leakiness, lymphatic vessel abnormalities, interstitial fibrosis and a

  4. Assessment of regional ventilation and deformation using 4D-CT imaging for healthy human lungs during tidal breathing.

    PubMed

    Jahani, Nariman; Choi, Sanghun; Choi, Jiwoong; Iyer, Krishna; Hoffman, Eric A; Lin, Ching-Long

    2015-11-15

    This study aims to assess regional ventilation, nonlinearity, and hysteresis of human lungs during dynamic breathing via image registration of four-dimensional computed tomography (4D-CT) scans. Six healthy adult humans were studied by spiral multidetector-row CT during controlled tidal breathing as well as during total lung capacity and functional residual capacity breath holds. Static images were utilized to contrast static vs. dynamic (deep vs. tidal) breathing. A rolling-seal piston system was employed to maintain consistent tidal breathing during 4D-CT spiral image acquisition, providing required between-breath consistency for physiologically meaningful reconstructed respiratory motion. Registration-derived variables including local air volume and anisotropic deformation index (ADI, an indicator of preferential deformation in response to local force) were employed to assess regional ventilation and lung deformation. Lobar distributions of air volume change during tidal breathing were correlated with those of deep breathing (R(2) ≈ 0.84). Small discrepancies between tidal and deep breathing were shown to be likely due to different distributions of air volume change in the left and the right lungs. We also demonstrated an asymmetric characteristic of flow rate between inhalation and exhalation. With ADI, we were able to quantify nonlinearity and hysteresis of lung deformation that can only be captured in dynamic images. Nonlinearity quantified by ADI is greater during inhalation, and it is stronger in the lower lobes (P < 0.05). Lung hysteresis estimated by the difference of ADI between inhalation and exhalation is more significant in the right lungs than that in the left lungs.

  5. Assessment of regional ventilation and deformation using 4D-CT imaging for healthy human lungs during tidal breathing

    PubMed Central

    Jahani, Nariman; Choi, Jiwoong; Iyer, Krishna; Hoffman, Eric A.

    2015-01-01

    This study aims to assess regional ventilation, nonlinearity, and hysteresis of human lungs during dynamic breathing via image registration of four-dimensional computed tomography (4D-CT) scans. Six healthy adult humans were studied by spiral multidetector-row CT during controlled tidal breathing as well as during total lung capacity and functional residual capacity breath holds. Static images were utilized to contrast static vs. dynamic (deep vs. tidal) breathing. A rolling-seal piston system was employed to maintain consistent tidal breathing during 4D-CT spiral image acquisition, providing required between-breath consistency for physiologically meaningful reconstructed respiratory motion. Registration-derived variables including local air volume and anisotropic deformation index (ADI, an indicator of preferential deformation in response to local force) were employed to assess regional ventilation and lung deformation. Lobar distributions of air volume change during tidal breathing were correlated with those of deep breathing (R2 ≈ 0.84). Small discrepancies between tidal and deep breathing were shown to be likely due to different distributions of air volume change in the left and the right lungs. We also demonstrated an asymmetric characteristic of flow rate between inhalation and exhalation. With ADI, we were able to quantify nonlinearity and hysteresis of lung deformation that can only be captured in dynamic images. Nonlinearity quantified by ADI is greater during inhalation, and it is stronger in the lower lobes (P < 0.05). Lung hysteresis estimated by the difference of ADI between inhalation and exhalation is more significant in the right lungs than that in the left lungs. PMID:26316512

  6. Computational biomechanics and experimental validation of vessel deformation based on 4D-CT imaging of the porcine aorta

    NASA Astrophysics Data System (ADS)

    Hazer, Dilana; Finol, Ender A.; Kostrzewa, Michael; Kopaigorenko, Maria; Richter, Götz-M.; Dillmann, Rüdiger

    2009-02-01

    Cardiovascular disease results from pathological biomechanical conditions and fatigue of the vessel wall. Image-based computational modeling provides a physical and realistic insight into the patient-specific biomechanics and enables accurate predictive simulations of development, growth and failure of cardiovascular disease. An experimental validation is necessary for the evaluation and the clinical implementation of such computational models. In the present study, we have implemented dynamic Computed-Tomography (4D-CT) imaging and catheter-based in vivo measured pressures to numerically simulate and experimentally evaluate the biomechanics of the porcine aorta. The computations are based on the Finite Element Method (FEM) and simulate the arterial wall response to the transient pressure-based boundary condition. They are evaluated by comparing the numerically predicted wall deformation and that calculated from the acquired 4D-CT data. The dynamic motion of the vessel is quantified by means of the hydraulic diameter, analyzing sequences at 5% increments over the cardiac cycle. Our results show that accurate biomechanical modeling is possible using FEM-based simulations. The RMS error of the computed hydraulic diameter at five cross-sections of the aorta was 0.188, 0.252, 0.280, 0.237 and 0.204 mm, which is equivalent to 1.7%, 2.3%, 2.7%, 2.3% and 2.0%, respectively, when expressed as a function of the time-averaged hydraulic diameter measured from the CT images. The present investigation is a first attempt to simulate and validate vessel deformation based on realistic morphological data and boundary conditions. An experimentally validated system would help in evaluating individual therapies and optimal treatment strategies in the field of minimally invasive endovascular surgery.

  7. Dynamic Multiscale Boundary Conditions for 4D CT Images of Healthy and Emphysematous Rat

    SciTech Connect

    Jacob, Rick E.; Carson, James P.; Thomas, Mathew; Einstein, Daniel R.

    2013-06-14

    Changes in the shape of the lung during breathing determine the movement of airways and alveoli, and thus impact airflow dynamics. Modeling airflow dynamics in health and disease is a key goal for predictive multiscale models of respiration. Past efforts to model changes in lung shape during breathing have measured shape at multiple breath-holds. However, breath-holds do not capture hysteretic differences between inspiration and expiration resulting from the additional energy required for inspiration. Alternatively, imaging dynamically – without breath-holds – allows measurement of hysteretic differences. In this study, we acquire multiple micro-CT images per breath (4DCT) in live rats, and from these images we develop, for the first time, dynamic volume maps. These maps show changes in local volume across the entire lung throughout the breathing cycle and accurately predict the global pressure-volume (PV) hysteresis.

  8. Is there an ideal set of prospective scan acquisition phases for fast-helical based 4D-CT?

    NASA Astrophysics Data System (ADS)

    Thomas, D. H.; Ruan, D.; Williams, P.; Lamb, J.; White, B. M.; Dou, T.; O'Connell, D.; Lee, P.; Low, D. A.

    2016-12-01

    The article aims to determine if a prospective acquisition algorithm can be used to find the ideal set of free-breathing phases for fast-helical model-based 4D-CT. A retrospective five-patient dataset that consisted of 25 repeated free breathing CT scans per patient was used. The sum of the square root amplitude difference between all the breathing phases was defined as an objective function to determine the optimality of sets of breathing phases. The objective function was intended to determine if a specific set of breathing phases would yield a motion model that could accurately predict the motion in all 25 CT scans. Voxel specific motion models were calculated using all combinations of N scans from 25 breathing trajectories, (3  ⩽  N  ⩽  25), and the minimum number of scans required to absolutely characterize the motion model was analyzed. This analysis suggests that the number of scans could potentially be reduced to as few as five scans. When the objective function was large, the resulting motion model provided an excellent approximation to the motion model created using all 25 scans.

  9. Respiratory motion variations from skin surface on lung cancer patients from 4D CT data

    NASA Astrophysics Data System (ADS)

    Gallego-Ortiz, Nicolas; Orban de Xivry, Jonathan; Descampe, Antonin; Goossens, Samuel; Geets, Xavier; Janssens, Guillaume; Macq, Benoit

    2014-03-01

    In radiation therapy of thorax and abdomen regions, knowing how respiratory motion modifies tumor position and trajectory is crucial for accurate dose delivery to tumors while avoiding healthy tissue and organs at risk. Three types of variations are studied: motion amplitudes measured from the patient's skin surface and internal tumor trajectory, internal/external correlations and tumor trajectory baseline shift. Four male patients with lung cancer with three repeated 4D computed tomography (4DCT) scans, taken on different treatment days, were studied. Surfaces were extracted from 4DCT scans by segmentation. Motion over specific regions of interest was analyzed with respect to the motion of the tumor center of mass and correlation coefficient was computed. Tumor baseline shifts were analyzed after rigid registration based on vertebrae and surface registration. External amplitude variations were observed between fractions. Correlation coefficients of internal trajectories and external distances are greater than 0.6 in the abdomen. This correlation was observable and significant for all patients showing that the external motion is a good surrogate for internal movement on an intra-fraction basis. However for the inter-fraction case, external amplitude variations were observed between fractions and no correlation was found with the internal amplitude variations. Moreover, baseline shifts after surface registration were greater than those after vertebrae registration and the mean distance between surfaces after registration was not correlated to the magnitude of the baseline shift. These two observations show that, with the current representation of the external surface, inter-fraction variations are not detectable on the surface.

  10. Measurement and modeling of 4D live mouse heart volumes from CT time series

    NASA Astrophysics Data System (ADS)

    Wetzel, Arthur W.; Badea, Cristian T.; Pomerantz, Stuart M.; Mistry, Nilesh; Nave, Démian; Johnson, G. Allan

    2007-01-01

    In vivo quantitative studies of cardiac function in mouse models provide information about cardiac pathophysiology in more detail than can be obtained in humans. Quantitative measurements of left ventricular (LV) volume at multiple contractile phases are particularly important. However, the mouse heart's small size and rapid motion present challenges for precise measurement in live animals. Researchers at Duke University's Center for In Vivo Microscopy (CIVM) have developed noninvasive time-gated microcomputed tomography (micro-CT) techniques providing the temporal and spatial resolutions required for in vivo characterization of cardiac structure and function. This paper describes analysis of the resulting reconstructions to produce volume measurements and corresponding models of heart motion. We believe these are the most precise noninvasive estimates of in vivo LV volume currently available. Our technique uses binary mixture models to directly recover volume estimates from reconstructed datasets. Unlike methods using segmentation followed by voxel counting, this approach provides statistical error estimates and maintains good precision at high noise levels. This is essential for long term multiple session experiments that must simultaneously minimize contrast agent and x-ray doses. The analysis tools are built into the Pittsburgh Supercomputing Center's Volume Browser (PSC-VB) that provides networked multi-site data sharing and collaboration including analysis and visualization functions.

  11. Evaluation of Fractional Regional Ventilation Using 4D-CT and Effects of Breathing Maneuvers on Ventilation

    SciTech Connect

    Mistry, Nilesh N.; Diwanji, Tejan; Shi, Xiutao; Pokharel, Sabin; Feigenberg, Steven; Scharf, Steven M.; D'Souza, Warren D.

    2013-11-15

    Purpose: Current implementations of methods based on Hounsfield units to evaluate regional lung ventilation do not directly incorporate tissue-based mass changes that occur over the respiratory cycle. To overcome this, we developed a 4-dimensional computed tomography (4D-CT)-based technique to evaluate fractional regional ventilation (FRV) that uses an individualized ratio of tidal volume to end-expiratory lung volume for each voxel. We further evaluated the effect of different breathing maneuvers on regional ventilation. The results from this work will help elucidate the relationship between global and regional lung function. Methods and Materials: Eight patients underwent 3 sets of 4D-CT scans during 1 session using free-breathing, audiovisual guidance, and active breathing control. FRV was estimated using a density-based algorithm with mass correction. Internal validation between global and regional ventilation was performed by use of the imaging data collected during the use of active breathing control. The impact of breathing maneuvers on FRV was evaluated comparing the tidal volume from 3 breathing methods. Results: Internal validation through comparison between the global and regional changes in ventilation revealed a strong linear correlation (slope of 1.01, R{sup 2} of 0.97) between the measured global lung volume and the regional lung volume calculated by use of the “mass corrected” FRV. A linear relationship was established between the tidal volume measured with the automated breathing control system and FRV based on 4D-CT imaging. Consistently larger breathing volumes were observed when coached breathing techniques were used. Conclusions: The technique presented improves density-based evaluation of lung ventilation and establishes a link between global and regional lung ventilation volumes. Furthermore, the results obtained are comparable with those of other techniques of functional evaluation such as spirometry and hyperpolarized-gas magnetic

  12. Computerized characterization of lung nodule subtlety using thoracic CT images

    NASA Astrophysics Data System (ADS)

    He, Xin; Sahiner, Berkman; Gallas, Brandon D.; Chen, Weijie; Petrick, Nicholas

    2014-02-01

    The goal of this work is to design computerized image analysis techniques for automatically characterizing lung nodule subtlety in CT images. Automated subtlety estimation methods may help in computer-aided detection (CAD) assessment by quantifying dataset difficulty and facilitating comparisons among different CAD algorithms. A dataset containing 813 nodules from 499 patients was obtained from the Lung Image Database Consortium. Each nodule was evaluated by four radiologists regarding nodule subtlety using a 5-point rating scale (1: most subtle). We developed a 3D technique for segmenting lung nodules using a prespecified initial ROI. Texture and morphological features were automatically extracted from the segmented nodules and their margins. The dataset was partitioned into trainers and testers using a 1:1 ratio. An artificial neural network (ANN) was trained with average reader subtlety scores as the reference. Effective features for characterizing nodule subtlety were selected based on the training set using the ANN and a stepwise feature selection method. The performance of the classifier was evaluated using prediction probability (PK) as an agreement measure, which is considered a generalization of the area under the receiver operating characteristic curve when the reference standard is multi-level. Using an ANN classifier trained with a set of 2 features (selected from a total of 30 features), including compactness and average gray value, the test concordance between computer scores and the average reader scores was 0.789 ± 0.014. Our results show that the proposed method had strong agreement with the average of subtlety scores provided by radiologists.

  13. SU-E-J-153: Reconstructing 4D Cone Beam CT Images for Clinical QA of Lung SABR Treatments

    SciTech Connect

    Beaudry, J; Bergman, A; Cropp, R

    2015-06-15

    Purpose: To verify that the planned Primary Target Volume (PTV) and Internal Gross Tumor Volume (IGTV) fully enclose a moving lung tumor volume as visualized on a pre-SABR treatment verification 4D Cone Beam CT. Methods: Daily 3DCBCT image sets were acquired immediately prior to treatment for 10 SABR lung patients using the on-board imaging system integrated into a Varian TrueBeam (v1.6: no 4DCBCT module available). Respiratory information was acquired during the scan using the Varian RPM system. The CBCT projections were sorted into 8 bins offline, both by breathing phase and amplitude, using in-house software. An iterative algorithm based on total variation minimization, implemented in the open source reconstruction toolkit (RTK), was used to reconstruct the binned projections into 4DCBCT images. The relative tumor motion was quantified by tracking the centroid of the tumor volume from each 4DCBCT image. Following CT-CBCT registration, the planning CT volumes were compared to the location of the CBCT tumor volume as it moves along its breathing trajectory. An overlap metric quantified the ability of the planned PTV and IGTV to contain the tumor volume at treatment. Results: The 4DCBCT reconstructed images visibly show the tumor motion. The mean overlap between the planned PTV (IGTV) and the 4DCBCT tumor volumes was 100% (94%), with an uncertainty of 5% from the 4DCBCT tumor volume contours. Examination of the tumor motion and overlap metric verify that the IGTV drawn at the planning stage is a good representation of the tumor location at treatment. Conclusion: It is difficult to compare GTV volumes from a 4DCBCT and a planning CT due to image quality differences. However, it was possible to conclude the GTV remained within the PTV 100% of the time thus giving the treatment staff confidence that SABR lung treatements are being delivered accurately.

  14. Automated pulmonary lobar ventilation measurements using volume-matched thoracic CT and MRI

    NASA Astrophysics Data System (ADS)

    Guo, F.; Svenningsen, S.; Bluemke, E.; Rajchl, M.; Yuan, J.; Fenster, A.; Parraga, G.

    2015-03-01

    Objectives: To develop and evaluate an automated registration and segmentation pipeline for regional lobar pulmonary structure-function measurements, using volume-matched thoracic CT and MRI in order to guide therapy. Methods: Ten subjects underwent pulmonary function tests and volume-matched 1H and 3He MRI and thoracic CT during a single 2-hr visit. CT was registered to 1H MRI using an affine method that incorporated block-matching and this was followed by a deformable step using free-form deformation. The resultant deformation field was used to deform the associated CT lobe mask that was generated using commercial software. 3He-1H image registration used the same two-step registration method and 3He ventilation was segmented using hierarchical k-means clustering. Whole lung and lobar 3He ventilation and ventilation defect percent (VDP) were generated by mapping ventilation defects to CT-defined whole lung and lobe volumes. Target CT-3He registration accuracy was evaluated using region- , surface distance- and volume-based metrics. Automated whole lung and lobar VDP was compared with semi-automated and manual results using paired t-tests. Results: The proposed pipeline yielded regional spatial agreement of 88.0+/-0.9% and surface distance error of 3.9+/-0.5 mm. Automated and manual whole lung and lobar ventilation and VDP were not significantly different and they were significantly correlated (r = 0.77, p < 0.0001). Conclusion: The proposed automated pipeline can be used to generate regional pulmonary structural-functional maps with high accuracy and robustness, providing an important tool for image-guided pulmonary interventions.

  15. Validating and improving CT ventilation imaging by correlating with ventilation 4D-PET/CT using {sup 68}Ga-labeled nanoparticles

    SciTech Connect

    Kipritidis, John Keall, Paul J.; Siva, Shankar; Hofman, Michael S.; Callahan, Jason; Hicks, Rodney J.

    2014-01-15

    Purpose: CT ventilation imaging is a novel functional lung imaging modality based on deformable image registration. The authors present the first validation study of CT ventilation using positron emission tomography with{sup 68}Ga-labeled nanoparticles (PET-Galligas). The authors quantify this agreement for different CT ventilation metrics and PET reconstruction parameters. Methods: PET-Galligas ventilation scans were acquired for 12 lung cancer patients using a four-dimensional (4D) PET/CT scanner. CT ventilation images were then produced by applying B-spline deformable image registration between the respiratory correlated phases of the 4D-CT. The authors test four ventilation metrics, two existing and two modified. The two existing metrics model mechanical ventilation (alveolar air-flow) based on Hounsfield unit (HU) change (V{sub HU}) or Jacobian determinant of deformation (V{sub Jac}). The two modified metrics incorporate a voxel-wise tissue-density scaling (ρV{sub HU} and ρV{sub Jac}) and were hypothesized to better model the physiological ventilation. In order to assess the impact of PET image quality, comparisons were performed using both standard and respiratory-gated PET images with the former exhibiting better signal. Different median filtering kernels (σ{sub m} = 0 or 3 mm) were also applied to all images. As in previous studies, similarity metrics included the Spearman correlation coefficient r within the segmented lung volumes, and Dice coefficient d{sub 20} for the (0 − 20)th functional percentile volumes. Results: The best agreement between CT and PET ventilation was obtained comparing standard PET images to the density-scaled HU metric (ρV{sub HU}) with σ{sub m} = 3 mm. This leads to correlation values in the ranges 0.22 ⩽ r ⩽ 0.76 and 0.38 ⩽ d{sub 20} ⩽ 0.68, with r{sup ¯}=0.42±0.16 and d{sup ¯}{sub 20}=0.52±0.09 averaged over the 12 patients. Compared to Jacobian-based metrics, HU-based metrics lead to statistically significant

  16. Towards a comprehensive CT image segmentation for thoracic organ radiation dose estimation and reporting

    NASA Astrophysics Data System (ADS)

    Lorenz, Cristian; Ruppertshofen, Heike; Vik, Torbjörn; Prinsen, Peter; Wiegert, Jens

    2014-03-01

    Administered dose of ionizing radiation during medical imaging is an issue of increasing concern for the patient, for the clinical community, and for respective regulatory bodies. CT radiation dose is currently estimated based on a set of very simplifying assumptions which do not take the actual body geometry and organ specific doses into account. This makes it very difficult to accurately report imaging related administered dose and to track it for different organs over the life of the patient. In this paper this deficit is addressed in a two-fold way. In a first step, the absorbed radiation dose in each image voxel is estimated based on a Monte-Carlo simulation of X-ray absorption and scattering. In a second step, the image is segmented into tissue types with different radio sensitivity. In combination this allows to calculate the effective dose as a weighted sum of the individual organ doses. The main purpose of this paper is to assess the feasibility of automatic organ specific dose estimation. With respect to a commercially applicable solution and respective robustness and efficiency requirements, we investigated the effect of dose sampling rather than integration over the organ volume. We focused on the thoracic anatomy as the exemplary body region, imaged frequently by CT. For image segmentation we applied a set of available approaches which allowed us to cover the main thoracic radio-sensitive tissue types. We applied the dose estimation approach to 10 thoracic CT datasets and evaluated segmentation accuracy and administered dose and could show that organ specific dose estimation can be achieved.

  17. Thoracic CT

    MedlinePlus

    ... Mitral valve regurgitation Noninvasive Pericarditis - after heart attack Pericarditis - constrictive Peripartum cardiomyopathy Pleural effusion Pneumonia - adults (community acquired) Pulmonary edema Restrictive cardiomyopathy Skin nodules SVC obstruction Swollen lymph nodes ...

  18. Radiation dose reduction in thoracic and abdomen-pelvic CT using tube current modulation: a phantom study.

    PubMed

    Sabarudin, Akmal; Mustafa, Zakira; Nassir, Khadijah Mohd; Hamid, Hamzaini Abdul; Sun, Zhonghua

    2015-01-01

    This phantom study was designed to compare the radiation dose in thoracic and abdomen-pelvic CT scans with and without use of tube current modulation (TCM). Effective dose (ED) and size-specific dose estimation (SSDE) were calculated with the absorbed doses measured at selective radiosensitive organs using a thermoluminescence dosimeter-100 (TLD-100). When compared to protocols without TCM, the ED and SSDE were reduced significantly with use of TCM for both the thoracic and abdomen-pelvic CT. With use of TCM, the ED was 6.50±0.29 mSv for thoracic and 6.01±0.20 mSv for the abdomen-pelvic CT protocols. However without use of TCM, the ED was 20.07±0.24 mSv and 17.30±0.41 mSv for the thoracic and abdomen-pelvic CT protocols, respectively. The corresponding SSDE was 10.18±0.48 mGy and 11.96±0.27 mGy for the thoracic and abdomen-pelvic CT protocols with TCM, and 31.56±0.43 mGy and 33.23±0.05 mGy for thoracic and abdomen-pelvic CT protocols without TCM, respectively. The highest absorbed dose was measured at the breast with 8.58±0.12 mGy in the TCM protocols and 51.52±14.72 mGy in the protocols without TCM during thoracic CT. In the abdomen-pelvic CT, the absorbed dose was highest at the skin with 9.30±1.28 mGy and 29.99±2.23 mGy in protocols with and without use of TCM, respectively. In conclusion, the TCM technique results in significant dose reduction; thus it is to be highly recommended in routine thoracic and abdomen-pelvic CT. PACS numbers: 87.57.Q-, 87.57.qp, 87.53.Bn.

  19. Radiation dose reduction in thoracic and abdomen-pelvic CT using tube current modulation: a phantom study.

    PubMed

    Sabarudin, Akmal; Mustafa, Zakira; Nassir, Khadijah Mohd; Hamid, Hamzaini Abdul; Sun, Zhonghua

    2014-01-08

    This phantom study was designed to compare the radiation dose in thoracic and abdomen-pelvic CT scans with and without use of tube current modulation (TCM). Effective dose (ED) and size-specific dose estimation (SSDE) were calculated with the absorbed doses measured at selective radiosensitive organs using a thermoluminescence dosimeter-100 (TLD-100). When compared to protocols without TCM, the ED and SSDE were reduced significantly with use of TCM for both the thoracic and abdomen-pelvic CT. With use of TCM, the ED was 6.50 ± 0.29 mSv for thoracic and 6.01 ± 0.20 mSv for the abdomen-pelvic CT protocols. However without use of TCM, the ED was 20.07 ± 0.24 mSv and 17.30 ± 0.41 mSv for the thoracic and abdomen-pelvic CT protocols, respectively. The corresponding SSDE was 10.18 ± 0.48 mGy and 11.96 ± 0.27 mGy for the thoracic and abdomen-pelvic CT protocols with TCM, and 31.56 ± 0.43 mGy and 33.23 ± 0.05 mGy for thoracic and abdomen-pelvic CT protocols without TCM, respectively. The highest absorbed dose was measured at the breast with 8.58 ± 0.12 mGy in the TCM protocols and 51.52 ± 14.72 mGy in the protocols without TCM during thoracic CT. In the abdomen-pelvic CT, the absorbed dose was highest at the skin with 9.30 ± 1.28mGy and 29.99 ± 2.23 mGy in protocols with and without use of TCM, respectively. In conclusion, the TCM technique results in significant dose reduction; thus it is to be highly recommended in routine thoracic and abdomen-pelvic CT.

  20. Comparison of thoracic radiographs and single breath-hold helical CT for detection of pulmonary nodules in dogs with metastatic neoplasia.

    PubMed

    Nemanic, Sarah; London, Cheryl A; Wisner, Erik R

    2006-01-01

    Imaging studies in people indicate that x-ray computed tomography (CT) is a more sensitive technique than thoracic radiography for the detection of pulmonary metastasic neoplasia. Systematic studies comparing CT and thoracic radiographic techniques in veterinary patients have not been performed. The present retrospective study was designed to directly compare the efficacy of these 2 techniques in detecting pulmonary nodules in dogs. Eighteen dogs with histologically confirmed pulmonary metastatic neoplasia had contemporaneous thoracic radiographs and pulmonary CT scans compared. Quantitative analyses included estimation of pulmonary nodule size, number, and lobar distribution on thoracic radiographs and CT images. Only 9% of CT-detected pulmonary nodules were identified on thoracic radiographs (P < .003). The lower size threshold was approximately 1 mm to detect pulmonary nodules on CT images and 7-9 mm to reliably detect nodules on radiographs (P < .0001). Additionally, pulmonary nodules were detected in a significantly greater number of lung lobes using CT as compared with thoracic radiographs (P < .0001). These data indicate that CT is significantly more sensitive than thoracic radiography for detecting soft-tissue nodules in dogs. As such, thoracic CT should be considered in any patient with neoplasia that has potential for pulmonary metastasis to more reliably stage the disease, particularly when accurate characterization of the extent and distribution of pulmonary metastatic disease affects therapeutic planning.

  1. A reappraisal of adult thoracic and abdominal surface anatomy via CT scan in Chinese population.

    PubMed

    Shen, Xin-Hua; Su, Bai-Yan; Liu, Jing-Juan; Zhang, Gu-Muyang; Xue, Hua-Dan; Jin, Zheng-Yu; Mirjalili, S Ali; Ma, Chao

    2016-03-01

    Accurate surface anatomy is essential for safe clinical practice. There are numerous inconsistencies in clinically important surface markings among and within contemporary anatomical reference texts. The aim of this study was to investigate key thoracic and abdominal surface anatomy landmarks in living Chinese adults using computed tomography (CT). A total of 100 thoracic and 100 abdominal CT scans were examined. Our results indicated that the following key surface landmarks differed from current commonly-accepted descriptions: the positions of the tracheal bifurcation, azygos vein termination, and pulmonary trunk bifurcation (all below the plane of the sternal angle at vertebral level T5-T6 in most individuals); the superior vena cava formation and junction with the right atrium (most often behind the 1st and 4th intercostal spaces, respectively); and the level at which the inferior vena cava and esophagus traverse the diaphragm (T10 and T11, respectively). The renal arteries were most commonly at L1; the midpoint of the renal hila was most frequently at L2; the 11th rib was posterior to the left kidney in only 29% of scans; and the spleen was most frequently located between the 10th and 12th ribs. A number of significant sex- and age-related differences were noted. The Chinese population was also compared with western populations on the basis of published reports. Reappraisal of surface anatomy using modern imaging tools in vivo will provide both quantitative and qualitative evidence to facilitate the clinical application of these key surface landmarks.

  2. Calcifications of the Thoracic Aorta on Extended Non-Contrast-Enhanced Cardiac CT

    PubMed Central

    Craiem, Damian; Chironi, Gilles; Casciaro, Mariano E.; Graf, Sebastian; Simon, Alain

    2014-01-01

    Background The presence of calcified atherosclerosis in different vascular beds has been associated with a higher risk of mortality. Thoracic aorta calcium (TAC) can be assessed from computed tomography (CT) scans, originally aimed at coronary artery calcium (CAC) assessment. CAC screening improves cardiovascular risk prediction, beyond standard risk assessment, whereas TAC performance remains controversial. However, the curvilinear portion of the thoracic aorta (TA), that includes the aortic arch, is systematically excluded from TAC analysis. We investigated the prevalence and spatial distribution of TAC all along the TA, to see how those segments that remain invisible in standard TA evaluation were affected. Methods and Results A total of 970 patients (77% men) underwent extended non-contrast cardiac CT scans including the aortic arch. An automated algorithm was designed to extract the vessel centerline and to estimate the vessel diameter in perpendicular planes. Then, calcifications were quantified using the Agatston score and associated with the corresponding thoracic aorta segment. The aortic arch and the proximal descending aorta, “invisible” in routine CAC screening, appeared as two vulnerable sites concentrating 60% of almost 11000 calcifications. The aortic arch was the most affected segment per cm length. Using the extended measurement method, TAC prevalence doubled from 31% to 64%, meaning that 52% of patients would escape detection with a standard scan. In a stratified analysis for CAC and/or TAC assessment, 111 subjects (46% women) were exclusively identified with the enlarged scan. Conclusions Calcium screening in the TA revealed that the aortic arch and the proximal descending aorta, hidden in standard TA evaluations, concentrated most of the calcifications. Middle-aged women were more prone to have calcifications in those hidden portions and became candidates for reclassification. PMID:25302677

  3. Intra-vascular blood velocity and volumetric flow rate calculated from dynamic 4D CT angiography using a time of flight technique.

    PubMed

    Barfett, Joseph John; Velauthapillai, Nivethan; Fierstra, Jorn; Crawley, Adrian; Coolens, Catherine; Crean, Andrew; Jaskolka, Jeff; Dufort, Paul; Krings, Timo; Mikulis, David

    2014-10-01

    We examine a time of flight (TOF) approach for the analysis of contrast enhanced 4D volumetric CT angiography scans to derive and display blood velocity in arteries. Software was written to divide blood vessels into a series of cross sections and to track contrast bolus TOF along the central vessel axis, which was defined by a user, from 4D CT source data. Time density curves at each vessel cross section were fit with quadratic, Gaussian, and gamma variate functions to determine bolus time to peak (TTP). A straight line was used to plot TTP versus vessel path length for all three functions and the slope used to calculate intraluminal velocity. Software was validated in a simulated square channel and non-pulsatile flow phantom prior to the calculation of blood velocity in the major cerebral arteries of 8 normal patients. The TOF algorithm correctly calculates intra-luminal fluid velocity in eight flow conditions of the CT flow phantom where quadratic functions were used. Across all conditions, in phantoms and in vivo, the success of calculations depended strongly on having a sufficiently long path length to make measurements and avoiding venous contamination. Total blood flow into the brain was approximately 17 % of a normal 5 L cardiac output. The technique was explored in vivo in a patient with subclavian steal syndrome, in the pulmonary arteries and in the iliac artery from clinical 4D CT source data. Intravascular blood velocity and flow may be calculated from 4D CT angiography using a TOF approach.

  4. SU-F-207-13: Comparison of Four Dimensional Computed Tomography (4D CT) Versus Breath Hold Images to Determine Pulmonary Nodule Elasticity

    SciTech Connect

    Negahdar, M; Loo, B; Maxim, P

    2015-06-15

    Purpose: Elasticity may distinguish malignant from benign pulmonary nodules. To compare determining of malignant pulmonary nodule (MPN) elasticity from four dimensional computed tomography (4D CT) images versus inhale/exhale breath-hold CT images. Methods: We analyzed phase 00 and 50 of 4D CT and deep inhale and natural exhale of breath-hold CT images of 30 MPN treated with stereotactic ablative radiotherapy (SABR). The radius of the smallest MPN was 0.3 cm while the biggest one was 2.1 cm. An intensity based deformable image registration (DIR) workflow was applied to the 4D CT and breath-hold images to determine the volumes of the MPNs and a 1 cm ring of surrounding lung tissue (ring) in each state. Next, an elasticity parameter was derived by calculating the ratio of the volume changes of MPN (exhale:inhale or phase50:phase00) to that of a 1 cm ring of lung tissue surrounding the MPN. The proposed formulation of elasticity enables us to compare volume changes of two different MPN in two different locations of lung. Results: The calculated volume ratio of MPNs from 4D CT (phase50:phase00) and breath-hold images (exhale:inhale) was 1.00±0.23 and 0.95±0.11, respectively. It shows the stiffness of MPN and comparably bigger volume changes of MPN in breath-hold images because of the deeper degree of inhalation. The calculated elasticity of MPNs from 4D CT and breath-hold images was 1.12±0.22 and 1.23±0.26, respectively. For five patients who have had two MPN in their lung, calculated elasticity of tumor A and tumor B follows same trend in both 4D CT and breath-hold images. Conclusion: We showed that 4D CT and breath-hold images are comparable in the ability to calculate the elasticity of MPN. This study has been supported by Department of Defense LCRP 2011 #W81XWH-12-1-0286.

  5. SU-E-J-207: Assessing the Validity of 4D-CT Based Target Volumes and Free Breathing CBCT Localization in Lung Stereotactic Ablative Radiation Therapy (SABR)

    SciTech Connect

    Badkul, R; Pokhrel, D; Jiang, H; Park, J; Wang, F; Kumar, P

    2014-06-01

    Purpose: Four-dimensional-computed-tomography(4D-CT) imaging for target-volume delineation and cone-beam-tomography(CBCT) for treatment localization are widely utilized in lung-SABR.Aim of this study was to perform a quantitative-assessment and inter-comparison of Internal-targetvolumes( ITV) drawn on various phases of breathing-cycle 4D-CT-scans, Maximum-intensity-projection(MIP), average-intensity-projection(AIP)and static CT-scans of lung-motion-phantom to simulate lung-SABR patient geometry. We also analyzed and compared the ITVs drawn on freebreathing- CBCT. Materials and Methods: 4D-CT-scans were acquired on Philips big-bore 16slice CT and Bellows-respiratory monitoring-system using retrospective phase-binning method. Each respiratory cycle divided into 10-phases. Quasar-Phantom with lung-inserts and 3cm-diameter nylonball to simulate tumor and was placed on respiratory-motion-platform for 4D-CT and CBCT-acquisition. Amplitudes of motions: 0.5,1.0,2.0,3.0cm in superior-inferior direction with breathing-cycle time of 6,5,4,6sec, respectively used.4D-CTs with 10-phases(0%to90%)for each excursion-set and 3D-CT for static-phantom exported to iPlan treatment-planningsystem( TPS).Tumor-volumes delineated in all phases of 4D-CT, MIP,AIP,CBCT scans using fixed-HU-threshold(−500to1000)values automatically.For each 4D-dataset ITV obtained by unifying the tumorcontours on all phases.CBCT-ITV-volumes were drawn in Eclipse-TPS. Results: Mean volume of tumor contours for all phases compared with static 3D-CT were 0.62±0.08%, 1.67±0.26%, 4.77±0.54% and 9.27±1.23% for 0.5cm,1cm,2cm,3cm excursions respectively. Differences of mean Union-ITV with MIP-ITV were close(≤2.4%).Mean Union-ITV from expected-theoretical values differed from −4.9% to 3.8%.Union-ITV and MIP-ITV were closer within 2.3%. AIP-ITVs were underestimated from 14 to 32% compared to union-ITV for all motion datasets. Differences of −5.9% to −44% and −5% to 6.7% for CBCT-ITV from MIP-ITV and AIP

  6. Evaluation of the combined effects of target size, respiratory motion and background activity on 3D and 4D PET/CT images

    NASA Astrophysics Data System (ADS)

    Park, Sang-June; Ionascu, Dan; Killoran, Joseph; Mamede, Marcelo; Gerbaudo, Victor H.; Chin, Lee; Berbeco, Ross

    2008-07-01

    Gated (4D) PET/CT has the potential to greatly improve the accuracy of radiotherapy at treatment sites where internal organ motion is significant. However, the best methodology for applying 4D-PET/CT to target definition is not currently well established. With the goal of better understanding how to best apply 4D information to radiotherapy, initial studies were performed to investigate the effect of target size, respiratory motion and target-to-background activity concentration ratio (TBR) on 3D (ungated) and 4D PET images. Using a PET/CT scanner with 4D or gating capability, a full 3D-PET scan corrected with a 3D attenuation map from 3D-CT scan and a respiratory gated (4D) PET scan corrected with corresponding attenuation maps from 4D-CT were performed by imaging spherical targets (0.5-26.5 mL) filled with 18F-FDG in a dynamic thorax phantom and NEMA IEC body phantom at different TBRs (infinite, 8 and 4). To simulate respiratory motion, the phantoms were driven sinusoidally in the superior-inferior direction with amplitudes of 0, 1 and 2 cm and a period of 4.5 s. Recovery coefficients were determined on PET images. In addition, gating methods using different numbers of gating bins (1-20 bins) were evaluated with image noise and temporal resolution. For evaluation, volume recovery coefficient, signal-to-noise ratio and contrast-to-noise ratio were calculated as a function of the number of gating bins. Moreover, the optimum thresholds which give accurate moving target volumes were obtained for 3D and 4D images. The partial volume effect and signal loss in the 3D-PET images due to the limited PET resolution and the respiratory motion, respectively were measured. The results show that signal loss depends on both the amplitude and pattern of respiratory motion. However, the 4D-PET successfully recovers most of the loss induced by the respiratory motion. The 5-bin gating method gives the best temporal resolution with acceptable image noise. The results based on the 4D

  7. Estimation of the delivered patient dose in lung IMRT treatment based on deformable registration of 4D-CT data and Monte Carlo simulations

    NASA Astrophysics Data System (ADS)

    Flampouri, Stella; Jiang, Steve B.; Sharp, Greg C.; Wolfgang, John; Patel, Abhijit A.; Choi, Noah C.

    2006-06-01

    The purpose of this study is to accurately estimate the difference between the planned and the delivered dose due to respiratory motion and free breathing helical CT artefacts for lung IMRT treatments, and to estimate the impact of this difference on clinical outcome. Six patients with representative tumour motion, size and position were selected for this retrospective study. For each patient, we had acquired both a free breathing helical CT and a ten-phase 4D-CT scan. A commercial treatment planning system was used to create four IMRT plans for each patient. The first two plans were based on the GTV as contoured on the free breathing helical CT set, with a GTV to PTV expansion of 1.5 cm and 2.0 cm, respectively. The third plan was based on the ITV, a composite volume formed by the union of the CTV volumes contoured on free breathing helical CT, end-of-inhale (EOI) and end-of-exhale (EOE) 4D-CT. The fourth plan was based on GTV contoured on the EOE 4D-CT. The prescribed dose was 60 Gy for all four plans. Fluence maps and beam setup parameters of the IMRT plans were used by the Monte Carlo dose calculation engine MCSIM for absolute dose calculation on both the free breathing CT and 4D-CT data. CT deformable registration between the breathing phases was performed to estimate the motion trajectory for both the tumour and healthy tissue. Then, a composite dose distribution over the whole breathing cycle was calculated as a final estimate of the delivered dose. EUD values were computed on the basis of the composite dose for all four plans. For the patient with the largest motion effect, the difference in the EUD of CTV between the planed and the delivered doses was 33, 11, 1 and 0 Gy for the first, second, third and fourth plan, respectively. The number of breathing phases required for accurate dose prediction was also investigated. With the advent of 4D-CT, deformable registration and Monte Carlo simulations, it is feasible to perform an accurate calculation of the

  8. Pulmonary nodule classification based on CT density distribution using 3D thoracic CT images

    NASA Astrophysics Data System (ADS)

    Kawata, Yoshiki; Niki, Noboru; Ohamatsu, Hironobu; Kusumoto, Masahiko; Kakinuma, Ryutaro; Mori, Kiyoshi; Yamada, Kozo; Nishiyama, Hiroyuki; Eguchi, Kenji; Kaneko, Masahiro; Moriyama, Noriyuki

    2004-04-01

    Computer-aided diagnosis (CAD) has been investigated to provide physicians with quantitative information, such as estimates of the malignant likelihood, to aid in the classification of abnormalities detected at screening of lung cancers. The purpose of this study is to develop a method for classifying nodule density patterns that provides information with respect to nodule statuses such as lesion stage. This method consists of three steps, nodule segmentation, histogram analysis of CT density inside nodule, and classifying nodules into five types based on histogram patterns. In this paper, we introduce a two-dimensional (2-D) joint histogram with respect to distance from nodule center and CT density inside nodule and explore numerical features with respect to shape and position of the joint histogram.

  9. Evaluation of contrast injection site effectiveness: thoracic CT angiography in children with hand injection of IV contrast material.

    PubMed

    Schooler, Gary R; Zurakowski, David; Lee, Edward Y

    2015-02-01

    OBJECTIVE. The purpose of this study was to evaluate the effectiveness of various contrast injection sites when performing thoracic CT angiography (CTA) using hand injection of IV contrast material in infants and young children with a small IV catheter. MATERIALS AND METHODS. We used our hospital information system to retrospectively identify consecutive pediatric patients who underwent thoracic CTA with hand injection of contrast material from August 2012 to July 2013. The study indication for thoracic CTA was to evaluate the thoracic systemic arterial vasculature and pulmonary venous vasculature. Both qualitative and quantitative evaluation of thoracic CTA image quality was performed by two reviewers independently. Qualitative evaluation of thoracic CTA image quality was performed by visual assessment of the degree of contrast enhancement in the ROI on a 4-point scale. Quantitative evaluation was performed by measuring attenuation obtained with the ROI placed within the aorta at two locations (the level of the aortic arch and at the level of the carina) to evaluate the thoracic systemic arterial vasculature. For evaluation of the pulmonary venous system, attenuation measurements were obtained at the center of the left atrium. Six individual injection sites were identified: head, jugular vein, arm vein, hand vein, leg vein, and foot vein. Injection sites were categorized into three regional groups: head-neck region (head vein and jugular veins), upper extremity region (arm and hand veins), and lower extremity region (leg and foot veins). Comparisons of attenuation values between individual and regionally grouped contrast injection sites were determined using the F-test in ANOVA. RESULTS. The study cohort included 50 pediatric patients (29 boys and 21 girls; mean age, 8 months ± 1 year; range, 1 week to 5 years) who underwent a total of 50 thoracic CTA studies for evaluating the thoracic systemic arterial vasculature (n = 38; 76%) or pulmonary venous vasculature

  10. Evaluation of a projection-domain lung nodule insertion technique in thoracic CT

    NASA Astrophysics Data System (ADS)

    Ma, Chi; Chen, Baiyu; Koo, Chi Wan; Takahashi, Edwin A.; Fletcher, Joel G.; McCollough, Cynthia H.; Levin, David L.; Kuzo, Ronald S.; Viers, Lyndsay D.; Vincent Sheldon, Stephanie A.; Leng, Shuai; Yu, Lifeng

    2016-04-01

    Task-based assessment of computed tomography (CT) image quality requires a large number of cases with ground truth. Inserting lesions into existing cases to simulate positive cases is a promising alternative approach. The aim of this study was to evaluate a recently-developed raw-data based lesion insertion technique in thoracic CT. Lung lesions were segmented from patient CT images, forward projected, and reinserted into the same patient CT projection data. In total, 32 nodules of various attenuations were segmented from 21 CT cases. Two experienced radiologists and 2 residents blinded to the process independently evaluated these inserted nodules in two sub-studies. First, the 32 inserted and the 32 original nodules were presented in a randomized order and each received a rating score from 1 to 10 (1=absolutely artificial to 10=absolutely realistic). Second, the inserted and the corresponding original lesions were presented side-by-side to each reader, who identified the inserted lesion and provided a confidence score (1=no confidence to 5=completely certain). For the randomized evaluation, discrimination of real versus artificial nodules was poor with areas under the receiver operative characteristic curves being 0.69 (95% CI: 0.58-0.78), 0.57 (95% CI: 0.46-0.68), and 0.62 (95% CI: 0.54-0.69) for the 2 radiologists, 2 residents, and all 4 readers, respectively. For the side-by-side evaluation, although all 4 readers correctly identified inserted lesions in 103/128 pairs, the confidence score was moderate (2.6). Our projection-domain based lung nodule insertion technique provides a robust method to artificially generate clinical cases that prove to be difficult to differentiate from real cases.

  11. Evaluation of a projection-domain lung nodule insertion technique in thoracic CT

    PubMed Central

    Ma, Chi; Chen, Baiyu; Koo, Chi Wan; Takahashi, Edwin A; Fletcher, Joel G; McCollough, Cynthia H; Levin, David L; Kuzo, Ronald S; Viers, Lyndsay D; Sheldon, Stephanie A Vincent; Leng, Shuai; Yu, Lifeng

    2016-01-01

    Task-based assessment of computed tomography (CT) image quality requires a large number of cases with ground truth. Inserting lesions into existing cases to simulate positive cases is a promising alternative approach. The aim of this study was to evaluate a recently-developed raw-data based lesion insertion technique in thoracic CT. Lung lesions were segmented from patient CT images, forward projected, and reinserted into the same patient CT projection data. In total, 32 nodules of various attenuations were segmented from 21 CT cases. Two experienced radiologists and 2 residents blinded to the process independently evaluated these inserted nodules in two sub-studies. First, the 32 inserted and the 32 original nodules were presented in a randomized order and each received a rating score from 1 to 10 (1=absolutely artificial to 10=absolutely realistic). Second, the inserted and the corresponding original lesions were presented side-by-side to each reader, who identified the inserted lesion and provided a confidence score (1=no confidence to 5=completely certain). For the randomized evaluation, discrimination of real versus artificial nodules was poor with areas under the receiver operative characteristic curves being 0.69 (95% CI: 0.58–0.78), 0.57 (95% CI: 0.46–0.68), and 0.62 (95% CI: 0.54–0.69) for the 2 radiologists, 2 residents, and all 4 readers, respectively. For the side-by-side evaluation, although all 4 readers correctly identified inserted lesions in 103/128 pairs, the confidence score was moderate (2.6). Our projection-domain based lung nodule insertion technique provides a robust method to artificially generate clinical cases that prove to be difficult to differentiate from real cases. PMID:27695156

  12. TH-E-17A-06: Anatomical-Adaptive Compressed Sensing (AACS) Reconstruction for Thoracic 4-Dimensional Cone-Beam CT

    SciTech Connect

    Shieh, C; Kipritidis, J; OBrien, R; Cooper, B; Kuncic, Z; Keall, P

    2014-06-15

    Purpose: The Feldkamp-Davis-Kress (FDK) algorithm currently used for clinical thoracic 4-dimensional (4D) cone-beam CT (CBCT) reconstruction suffers from noise and streaking artifacts due to projection under-sampling. Compressed sensing theory enables reconstruction of under-sampled datasets via total-variation (TV) minimization, but TV-minimization algorithms such as adaptive-steepest-descent-projection-onto-convex-sets (ASD-POCS) often converge slowly and are prone to over-smoothing anatomical details. These disadvantages can be overcome by incorporating general anatomical knowledge via anatomy segmentation. Based on this concept, we have developed an anatomical-adaptive compressed sensing (AACS) algorithm for thoracic 4D-CBCT reconstruction. Methods: AACS is based on the ASD-POCS framework, where each iteration consists of a TV-minimization step and a data fidelity constraint step. Prior to every AACS iteration, four major thoracic anatomical structures - soft tissue, lungs, bony anatomy, and pulmonary details - were segmented from the updated solution image. Based on the segmentation, an anatomical-adaptive weighting was applied to the TV-minimization step, so that TV-minimization was enhanced at noisy/streaky regions and suppressed at anatomical structures of interest. The image quality and convergence speed of AACS was compared to conventional ASD-POCS using an XCAT digital phantom and a patient scan. Results: For the XCAT phantom, the AACS image represented the ground truth better than the ASD-POCS image, giving a higher structural similarity index (0.93 vs. 0.84) and lower absolute difference (1.1*10{sup 4} vs. 1.4*10{sup 4}). For the patient case, while both algorithms resulted in much less noise and streaking than FDK, the AACS image showed considerably better contrast and sharpness of the vessels, tumor, and fiducial marker than the ASD-POCS image. In addition, AACS converged over 50% faster than ASD-POCS in both cases. Conclusions: The proposed AACS

  13. WE-AB-204-03: A Novel 3D Printed Phantom for 4D PET/CT Imaging and SIB Radiotherapy Verification

    SciTech Connect

    Soultan, D; Murphy, J; Moiseenko, V; Cervino, L; Gill, B

    2015-06-15

    Purpose: To construct and test a 3D printed phantom designed to mimic variable PET tracer uptake seen in lung tumor volumes. To assess segmentation accuracy of sub-volumes of the phantom following 4D PET/CT scanning with ideal and patient-specific respiratory motion. To plan, deliver and verify delivery of PET-driven, gated, simultaneous integrated boost (SIB) radiotherapy plans. Methods: A set of phantoms and inserts were designed and manufactured for a realistic representation of lung cancer gated radiotherapy steps from 4D PET/CT scanning to dose delivery. A cylindrical phantom (40x 120 mm) holds inserts for PET/CT scanning. The novel 3D printed insert dedicated to 4D PET/CT mimics high PET tracer uptake in the core and lower uptake in the periphery. This insert is a variable density porous cylinder (22.12×70 mm), ABS-P430 thermoplastic, 3D printed by uPrint SE Plus with inner void volume (5.5×42 mm). The square pores (1.8×1.8 mm2 each) fill 50% of outer volume, resulting in a 2:1 SUV ratio of PET-tracer in the void volume with respect to porous volume. A matching in size cylindrical phantom is dedicated to validate gated radiotherapy. It contains eight peripheral holes matching the location of the porous part of the 3D printed insert, and one central hole. These holes accommodate adaptors for Farmer-type ion chamber and cells vials. Results: End-to-end test were performed from 4D PET/CT scanning to transferring data to the planning system and target volume delineation. 4D PET/CT scans were acquired of the phantom with different respiratory motion patterns and gating windows. A measured 2:1 18F-FDG SUV ratio between inner void and outer volume matched the 3D printed design. Conclusion: The novel 3D printed phantom mimics variable PET tracer uptake typical of tumors. Obtained 4D PET/CT scans are suitable for segmentation, treatment planning and delivery in SIB gated treatments of NSCLC.

  14. Customized CT angiogram planning for intraoperative transesophageal echography-guided endovascular exclusion of thoracic aorta penetrating ulcer.

    PubMed

    Piazza, Michele; Lupia, Mario; Grego, Franco; Antonello, Michele

    2015-04-01

    The technique is demonstrated in a 78-year-old man; the preoperative CT angiogram showed a descending thoracic aorta ulcer of 5.9 cm in maximum diameter and 3.8 cm longitudinal extension. A ZTEG-2P-36-127-PF (Cook Medical) single tubular endograft was planned to be deployed. From the preoperative CT angiogram we planned to land 4.7 cm above the midline of the descending thoracic aorta ulcer and 8.0 cm below. In the operating room, under radioscopic vision the centre of the transesophageal echography probe was used as marker to identify the correspondent midline of the descending thoracic aorta ulcer and a centimeter-sized pigtail catheter in the aorta was used to calculate the desired length above and below the ulcer midline. The endograft was introduced and placed in the desired position compared to the transesophageal echography probe and the catheter; under transesophageal echography vision the graft was finally deployed. The CT angiogram at 1 month showed the correct endograft position, descending thoracic aorta ulcer exclusion with no signs of endoleak. In selected cases, this method allows planning in advance safe stent graft positioning and deployment totally assisted by transesophageal echography, with no risk of periprocedural contrast-related renal failure and reduced radiation exposure for the patient and operators.

  15. Incidental Paratracheal Air Cysts on Thoracic CT and Their Association with Chronic Inflammatory Lung Disease

    PubMed Central

    Kim, Ha Yeon; Lee, Kyung Hee; Kim, Yeo Ju; Lee, Ha Young; Kim, Ga Ram; Jeon, Yong Sun; Kim, Jung Soo; Kim, Young Sam

    2017-01-01

    Purpose. To determine the association between the progression of upper lung fibrosis and paratracheal air cysts (PACs) size. Materials and Methods. The thoracic CT images of 4573 patients were reviewed for the prevalence, size, and location of PACs and their communication with trachea. In addition, the presence of upper lung fibrosis, emphysema, and bronchiectasis was evaluated in patients with PACs and compared with a control group without PACs. Upper lung fibrosis was analyzed using a fibrosis score system. Results. The prevalence of PACs was 6.8%. Communication with tracheal lumen was demonstrated by 31.5% of patients with PACs. The prevalence of fibrosis, emphysema, and bronchiectasis in patients with PACs were 67.5%, 21.9%, and 28.3%, respectively. The prevalence of fibrosis was significantly different in the two groups by univariable and multivariable analysis (odds ratio = 2.077, P < 0.001). 140 patients with fibrosis among PAC group underwent a previous or follow-up CT; the prevalence with increase in PAC sizes was higher in patients with increase in fibrosis score than those without it (66.2% versus 17.3%, P < 0.001). Conclusions. PACs appear to be highly related to upper lung fibrosis and moderately related to bronchiectasis. In patients with fibrosis, PAC sizes tended to increase with the progression of upper lung fibrosis.

  16. Simulation of dosimetric consequences of 4D-CT-based motion margin estimation for proton radiotherapy using patient tumor motion data

    NASA Astrophysics Data System (ADS)

    Koybasi, Ozhan; Mishra, Pankaj; St. James, Sara; Lewis, John H.; Seco, Joao

    2014-02-01

    For the radiation treatment of lung cancer patients, four-dimensional computed tomography (4D-CT) is a common practice used clinically to image tumor motion and subsequently determine the internal target volume (ITV) from the maximum intensity projection (MIP) images. ITV, which is derived from short pre-treatment 4D-CT scan (<6 s per couch position), may not adequately cover the extent of tumor motion during the treatment, particularly for patients that exhibit a large respiratory variability. Inaccurate tumor localization may result in under-dosage of the tumor or over-dosage of the surrounding tissues. The purpose of this study is therefore to assess the degree of tumor under-dosage in case of regular and irregular breathing for proton radiotherapy using ITV-based treatment planning. We place a spherical lesion into a modified XCAT phantom that is also capable of producing 4D images based on irregular breathing, and move the tumor according to real tumor motion data, which is acquired over multiple days by tracking gold fiducial markers implanted into the lung tumors of patients. We derive ITVs by taking the union of all tumor positions during 6 s of tumor motion in the phantom using the first day patient tumor tracking data. This is equivalent to ITVs generated clinically from cine-mode 4D-CT MIP images. The treatment plans created for different ITVs are then implemented on dynamic phantoms with tumor motion governed by real tumor tracking data from consecutive days. By comparing gross tumor volume dose distribution on days of ‘treatment’ with the ITV dose distribution, we evaluate the deviation of the actually delivered dose from the predicted dose. Our results have shown that the proton treatment planning on ITV derived from pre-treatment cine-mode 4D-CT can result in under-dosage (dose covering 95% of volume) of the tumor by up to 25.7% over 3 min of treatment for the patient with irregular respiratory motion. Tumor under-dosage is less significant for

  17. Performance evaluation and optimization of BM4D-AV denoising algorithm for cone-beam CT images

    NASA Astrophysics Data System (ADS)

    Huang, Kuidong; Tian, Xiaofei; Zhang, Dinghua; Zhang, Hua

    2015-12-01

    The broadening application of cone-beam Computed Tomography (CBCT) in medical diagnostics and nondestructive testing, necessitates advanced denoising algorithms for its 3D images. The block-matching and four dimensional filtering algorithm with adaptive variance (BM4D-AV) is applied to the 3D image denoising in this research. To optimize it, the key filtering parameters of the BM4D-AV algorithm are assessed firstly based on the simulated CBCT images and a table of optimized filtering parameters is obtained. Then, considering the complexity of the noise in realistic CBCT images, possible noise standard deviations in BM4D-AV are evaluated to attain the chosen principle for the realistic denoising. The results of corresponding experiments demonstrate that the BM4D-AV algorithm with optimized parameters presents excellent denosing effect on the realistic 3D CBCT images.

  18. SU-E-T-330: To Analyze the Calculation Error of Live Dose-Volume Indices Applying 4D-CT in Radiotherapy for PTVs Within the Liver Completely

    SciTech Connect

    Gong, G; Liu, C; Yin, Y

    2014-06-01

    Purpose: To study the variation rule of normal liver dose-volume indices calculation for the liver malignancy patients whose plan target volumes were in the liver completely in all breath phases. Methods: Ten patients who accepted radiotherapy for malignant tumor were selected in our study. All patients underwent 4D-CT simulation and 3D-CT simulation in free breathing(FB). 4D-CT was sorted into 10 series CT images according to breath phase, named CT0, CT10 to CT90, respectively. And GTVs were contoured on different CT series, and the individual target volume(ITV) was obtained by merging 10 GTVs from 4D-CT. The PTVs were obtained from ITV applying margins. The PTVs were not beyond the boundary of liver in all breath phase observed by dynamic 4D-CT. The radiotherapy plans were designed and irradiation dose was calculated on 3D-CT images, and the livers were contoured on different series CT images and mapped to 3D-CT images applying rigid registration. To compare the dose-volume difference of livers based on distinct CT images. Results: (1)The liver volumes were similar on 4D-CT and 3D-CT images(CTFB 1485±500cm{sup 3}, CT0 1413±377cm{sup 3}, CT10 1409±396cm{sup 3}, CT20 1419±418cm{sup 3},CT30 1485±500cm{sup 3}, CT40 1438±392cm{sup 3}, CT50 1437±404cm{sup 3}, CT60 1439±409cm{sup 3}, CT70 1408±393cm{sup 3}, CT80 1384±397cm{sup 3}, CT90 1398±397cm{sup 3}; F=0.064,p=1.00) (2) The PTVs volume were 30.17±14.62cm{sup 3};(3) The mean dose and V5 to V10 of liver were similar among 4D-CT different series CT images(p>0.05), and the indices varied less than ±4% refer to liver on CT50. Conclusion: The calculation affection of liver dose-volume indices induced by breath motion were not significant for the PTV within liver completely as estimation before. And more objective prediction indices for radiation induced l.

  19. Thoracic computerized tomographic (CT) findings in 2009 influenza A (H1N1) virus infection in Isfahan, Iran

    PubMed Central

    Rostami, Mojtaba; Javadi, Abbas-Ali; Khorvash, Farzin; Mostafavizadeh, Kamyar; Adibi, Atoosa; Babak, Anahita; Ataei, Behrooz; Meidani, Mohsen; Naeini, Alireza Emami; Salehi, Hasan; Avijgan, Majid; Yazdani, Mohammad Reza; Rezaei, Farshid

    2011-01-01

    BACKGROUND: Pandemic 2009 H1N1 influenza A virus arrived at Isfahan in August 2009. The virus is still circulating in the world. The abnormal thoracic computerized tomographic (CT) scan findings vary widely among the studies of 2009 H1N1 influenza. We evaluated the thoracic CT findings in patients with 2009 H1N1 virus infection to describe findings compared to previously reported findings, and to suggest patterns that may be suggestive for 2009 influenza A (H1N1) in an appropriate clinical setting. METHODS: Retrospectively, the archive of all patients with a diagnosis of 2009 H1N1 influenza A were reviewed, in Al-Zahra Hospital in Isfahan, central Iran, between September 23rd 2009 to February 20th 2010. Out of 216 patients with confirmed 2009 influenza A (H1N1) virus, 26 cases with abnormal CT were enrolled in the study. Radiologic findings were characterized by the type and pattern of opacities and zonal distribution. RESULTS: Patchy infiltration (34.6%), lobar consolidation (30.8%), and interstitial infiltration (26.9%) with airbronchogram (38.5%) were the predominant findings in our patients. Bilateral distribution was seen in 80.8% of the patients. Only one patient (3.8%) showed ground-glass opacity, predominant radiographic finding in the previous reports and severe acute respiratory syndrome (SARS). CONCLUSIONS: The most common thoracic CT findings in pandemic H1N1 were patchy infiltration, lobar consolidation, and interstitial infiltration with airbronchogram and bilateral distribution. While these findings can be associated with other infections; they may be suggestive to 2009 influenza A (H1N1) in the appropriate clinical setting. Various radiographic patterns can be seen in thoracic CT scans of the influenza patients. Imaging findings are nonspecific. PMID:22091280

  20. Imaging and dosimetric errors in 4D PET/CT-guided radiotherapy from patient-specific respiratory patterns: a dynamic motion phantom end-to-end study

    NASA Astrophysics Data System (ADS)

    Bowen, S. R.; Nyflot, M. J.; Herrmann, C.; Groh, C. M.; Meyer, J.; Wollenweber, S. D.; Stearns, C. W.; Kinahan, P. E.; Sandison, G. A.

    2015-05-01

    Effective positron emission tomography / computed tomography (PET/CT) guidance in radiotherapy of lung cancer requires estimation and mitigation of errors due to respiratory motion. An end-to-end workflow was developed to measure patient-specific motion-induced uncertainties in imaging, treatment planning, and radiation delivery with respiratory motion phantoms and dosimeters. A custom torso phantom with inserts mimicking normal lung tissue and lung lesion was filled with [18F]FDG. The lung lesion insert was driven by six different patient-specific respiratory patterns or kept stationary. PET/CT images were acquired under motionless ground truth, tidal breathing motion-averaged (3D), and respiratory phase-correlated (4D) conditions. Target volumes were estimated by standardized uptake value (SUV) thresholds that accurately defined the ground-truth lesion volume. Non-uniform dose-painting plans using volumetrically modulated arc therapy were optimized for fixed normal lung and spinal cord objectives and variable PET-based target objectives. Resulting plans were delivered to a cylindrical diode array at rest, in motion on a platform driven by the same respiratory patterns (3D), or motion-compensated by a robotic couch with an infrared camera tracking system (4D). Errors were estimated relative to the static ground truth condition for mean target-to-background (T/Bmean) ratios, target volumes, planned equivalent uniform target doses, and 2%-2 mm gamma delivery passing rates. Relative to motionless ground truth conditions, PET/CT imaging errors were on the order of 10-20%, treatment planning errors were 5-10%, and treatment delivery errors were 5-30% without motion compensation. Errors from residual motion following compensation methods were reduced to 5-10% in PET/CT imaging, <5% in treatment planning, and <2% in treatment delivery. We have demonstrated that estimation of respiratory motion uncertainty and its propagation from PET/CT imaging to RT planning, and RT

  1. TU-F-12A-05: Sensitivity of Textural Features to 3D Vs. 4D FDG-PET/CT Imaging in NSCLC Patients

    SciTech Connect

    Yang, F; Nyflot, M; Bowen, S; Kinahan, P; Sandison, G

    2014-06-15

    Purpose: Neighborhood Gray-level difference matrices (NGLDM) based texture parameters extracted from conventional (3D) 18F-FDG PET scans in patients with NSCLC have been previously shown to associate with response to chemoradiation and poorer patient outcome. However, the change in these parameters when utilizing respiratory-correlated (4D) FDG-PET scans has not yet been characterized for NSCLC. The Objectives: of this study was to assess the extent to which NGLDM-based texture parameters on 4D PET images vary with reference to values derived from 3D scans in NSCLC. Methods: Eight patients with newly diagnosed NSCLC treated with concomitant chemoradiotherapy were included in this study. 4D PET scans were reconstructed with OSEM-IR in 5 respiratory phase-binned images and corresponding CT data of each phase were employed for attenuation correction. NGLDM-based texture features, consisting of coarseness, contrast, busyness, complexity and strength, were evaluated for gross tumor volumes defined on 3D/4D PET scans by radiation oncologists. Variation of the obtained texture parameters over the respiratory cycle were examined with respect to values extracted from 3D scans. Results: Differences between texture parameters derived from 4D scans at different respiratory phases and those extracted from 3D scans ranged from −30% to 13% for coarseness, −12% to 40% for contrast, −5% to 50% for busyness, −7% to 38% for complexity, and −43% to 20% for strength. Furthermore, no evident correlations were observed between respiratory phase and 4D scan texture parameters. Conclusion: Results of the current study showed that NGLDM-based texture parameters varied considerably based on choice of 3D PET and 4D PET reconstruction of NSCLC patient images, indicating that standardized image acquisition and analysis protocols need to be established for clinical studies, especially multicenter clinical trials, intending to validate prognostic values of texture features for NSCLC.

  2. Automatic detection of large pulmonary solid nodules in thoracic CT images

    SciTech Connect

    Setio, Arnaud A. A. Jacobs, Colin; Gelderblom, Jaap; Ginneken, Bram van

    2015-10-15

    Purpose: Current computer-aided detection (CAD) systems for pulmonary nodules in computed tomography (CT) scans have a good performance for relatively small nodules, but often fail to detect the much rarer larger nodules, which are more likely to be cancerous. We present a novel CAD system specifically designed to detect solid nodules larger than 10 mm. Methods: The proposed detection pipeline is initiated by a three-dimensional lung segmentation algorithm optimized to include large nodules attached to the pleural wall via morphological processing. An additional preprocessing is used to mask out structures outside the pleural space to ensure that pleural and parenchymal nodules have a similar appearance. Next, nodule candidates are obtained via a multistage process of thresholding and morphological operations, to detect both larger and smaller candidates. After segmenting each candidate, a set of 24 features based on intensity, shape, blobness, and spatial context are computed. A radial basis support vector machine (SVM) classifier was used to classify nodule candidates, and performance was evaluated using ten-fold cross-validation on the full publicly available lung image database consortium database. Results: The proposed CAD system reaches a sensitivity of 98.3% (234/238) and 94.1% (224/238) large nodules at an average of 4.0 and 1.0 false positives/scan, respectively. Conclusions: The authors conclude that the proposed dedicated CAD system for large pulmonary nodules can identify the vast majority of highly suspicious lesions in thoracic CT scans with a small number of false positives.

  3. The relationship between organ dose and patient size in tube current modulated adult thoracic CT scans

    NASA Astrophysics Data System (ADS)

    Khatonabadi, Maryam; Zhang, Di; Yang, Jeffrey; DeMarco, John J.; Cagnon, Chris C.; McNitt-Gray, Michael F.

    2012-03-01

    Recently published AAPM Task Group 204 developed conversion coefficients that use scanner reported CTDIvol to estimate dose to the center of patient undergoing fixed tube current body exam. However, most performed CT exams use TCM to reduce dose to patients. Therefore, the purpose of this study was to investigate the correlation between organ dose and a variety of patient size metrics in adult chest CT scans that use tube current modulation (TCM). Monte Carlo simulations were performed for 32 voxelized models with contoured lungs and glandular breasts tissue, consisting of females and males. These simulations made use of patient's actual TCM data to estimate organ dose. Using image data, different size metrics were calculated, these measurements were all performed on one slice, at the level of patient's nipple. Estimated doses were normalized by scanner-reported CTDIvol and plotted versus different metrics. CTDIvol values were plotted versus different metrics to look at scanner's output versus size. The metrics performed similarly in terms of correlating with organ dose. Looking at each gender separately, for male models normalized lung dose showed a better linear correlation (r2=0.91) with effective diameter, while female models showed higher correlation (r2=0.59) with the anterior-posterior measurement. There was essentially no correlation observed between size and CTDIvol-normalized breast dose. However, a linear relationship was observed between absolute breast dose and size. Dose to lungs and breasts were consistently higher in females with similar size as males which could be due to shape and composition differences between genders in the thoracic region.

  4. Pseudoaneurysm of the thoracic aorta sustained during exposure to a tornado diagnosed with ECG-synchronized CT aortography.

    PubMed

    Chakraborty, Amit; von Herrmann, Paul F; Embertson, Ryan E; Landwehr, Kevin P; Winkler, Michael A

    2016-01-01

    A case of a tornado victim with a delayed presentation of injury to the aortic isthmus is discussed. Tornado forces resemble the forces of high energy explosions, and the injuries that can occur as a result of these forces can be bizarre. The patient presented with the unique computed tomography (CT) findings of isolated pseudoaneurysm of the thoracic aorta in the absence of other traumatic injury to the thorax. Equivocal results of the initial CT aortogram (CTA) were confirmed with ECG-synchronized CTA (ECG-CTA), demonstrating the superiority of ECG-CTA as compared to standard CTA.

  5. Shape-based computer-aided detection of lung nodules in thoracic CT images.

    PubMed

    Ye, Xujiong; Lin, Xinyu; Dehmeshki, Jamshid; Slabaugh, Greg; Beddoe, Gareth

    2009-07-01

    In this paper, a new computer tomography (CT) lung nodule computer-aided detection (CAD) method is proposed for detecting both solid nodules and ground-glass opacity (GGO) nodules (part solid and nonsolid). This method consists of several steps. First, the lung region is segmented from the CT data using a fuzzy thresholding method. Then, the volumetric shape index map, which is based on local Gaussian and mean curvatures, and the "dot" map, which is based on the eigenvalues of a Hessian matrix, are calculated for each voxel within the lungs to enhance objects of a specific shape with high spherical elements (such as nodule objects). The combination of the shape index (local shape information) and "dot" features (local intensity dispersion information) provides a good structure descriptor for the initial nodule candidates generation. Antigeometric diffusion, which diffuses across the image edges, is used as a preprocessing step. The smoothness of image edges enables the accurate calculation of voxel-based geometric features. Adaptive thresholding and modified expectation-maximization methods are employed to segment potential nodule objects. Rule-based filtering is first used to remove easily dismissible nonnodule objects. This is followed by a weighted support vector machine (SVM) classification to further reduce the number of false positive (FP) objects. The proposed method has been trained and validated on a clinical dataset of 108 thoracic CT scans using a wide range of tube dose levels that contain 220 nodules (185 solid nodules and 35 GGO nodules) determined by a ground truth reading process. The data were randomly split into training and testing datasets. The experimental results using the independent dataset indicate an average detection rate of 90.2%, with approximately 8.2 FP/scan. Some challenging nodules such as nonspherical nodules and low-contrast part-solid and nonsolid nodules were identified, while most tissues such as blood vessels were excluded

  6. SU-E-J-151: Dosimetric Evaluation of DIR Mapped Contours for Image Guided Adaptive Radiotherapy with 4D Cone-Beam CT

    SciTech Connect

    Balik, S; Weiss, E; Williamson, J; Hugo, G; Jan, N; Zhang, L; Roman, N; Christensen, G

    2014-06-01

    Purpose: To estimate dosimetric errors resulting from using contours deformably mapped from planning CT to 4D cone beam CT (CBCT) images for image-guided adaptive radiotherapy of locally advanced non-small cell lung cancer (NSCLC). Methods: Ten locally advanced non-small cell lung cancer (NSCLC) patients underwent one planning 4D fan-beam CT (4DFBCT) and weekly 4DCBCT scans. Multiple physicians delineated the gross tumor volume (GTV) and normal structures in planning CT images and only GTV in CBCT images. Manual contours were mapped from planning CT to CBCTs using small deformation, inverse consistent linear elastic (SICLE) algorithm for two scans in each patient. Two physicians reviewed and rated the DIR-mapped (auto) and manual GTV contours as clinically acceptable (CA), clinically acceptable after minor modification (CAMM) and unacceptable (CU). Mapped normal structures were visually inspected and corrected if necessary, and used to override tissue density for dose calculation. CTV (6mm expansion of GTV) and PTV (5mm expansion of CTV) were created. VMAT plans were generated using the DIR-mapped contours to deliver 66 Gy in 33 fractions with 95% and 100% coverage (V66) to PTV and CTV, respectively. Plan evaluation for V66 was based on manual PTV and CTV contours. Results: Mean PTV V66 was 84% (range 75% – 95%) and mean CTV V66 was 97% (range 93% – 100%) for CAMM scored plans (12 plans); and was 90% (range 80% – 95%) and 99% (range 95% – 100%) for CA scored plans (7 plans). The difference in V66 between CAMM and CA was significant for PTV (p = 0.03) and approached significance for CTV (p = 0.07). Conclusion: The quality of DIR-mapped contours directly impacted the plan quality for 4DCBCT-based adaptation. Larger safety margins may be needed when planning with auto contours for IGART with 4DCBCT images. Reseach was supported by NIH P01CA116602.

  7. 4D cone-beam CT imaging for guidance in radiation therapy: setup verification by use of implanted fiducial markers

    NASA Astrophysics Data System (ADS)

    Jin, Peng; van Wieringen, Niek; Hulshof, Maarten C. C. M.; Bel, Arjan; Alderliesten, Tanja

    2016-03-01

    The use of 4D cone-beam computed tomography (CBCT) and fiducial markers for guidance during radiation therapy of mobile tumors is challenging due to the trade-off between image quality, imaging dose, and scanning time. We aimed to investigate the visibility of markers and the feasibility of marker-based 4D registration and manual respiration-induced marker motion quantification for different CBCT acquisition settings. A dynamic thorax phantom and a patient with implanted gold markers were included. For both the phantom and patient, the peak-to-peak amplitude of marker motion in the cranial-caudal direction ranged from 5.3 to 14.0 mm, which did not affect the marker visibility and the associated marker-based registration feasibility. While using a medium field of view (FOV) and the same total imaging dose as is applied for 3D CBCT scanning in our clinic, it was feasible to attain an improved marker visibility by reducing the imaging dose per projection and increasing the number of projection images. For a small FOV with a shorter rotation arc but similar total imaging dose, streak artifacts were reduced due to using a smaller sampling angle. Additionally, the use of a small FOV allowed reducing total imaging dose and scanning time (~2.5 min) without losing the marker visibility. In conclusion, by using 4D CBCT with identical or lower imaging dose and a reduced gantry speed, it is feasible to attain sufficient marker visibility for marker-based 4D setup verification. Moreover, regardless of the settings, manual marker motion quantification can achieve a high accuracy with the error <1.2 mm.

  8. Preliminary study of visualizing membrane structures of spiculated pulmonary nodules in three-dimensional thoracic CT images

    NASA Astrophysics Data System (ADS)

    Kawata, Y.; Niki, N.; Ohmatsu, H.; Aokage, K.; Kusumoto, M.; Tsuchida, T.; Eguchi, K.; Kaneko, M.

    2016-03-01

    Research results from the National Lung Screening Trial revealed that screening for lung cancer with low-dose CT (LDCT) reduces lung cancer mortality in heavy smokers by 20% compared to radiography. While this study does show the efficacy of CT-based screening, radiologists often face the problem of estimating the malignant likelihoods of pulmonary nodules detected on LDCT screening for maximizing patient survival and for preserving lung function. Spiculation is considered as one of the indicators of nodule malignancy and an important feature to assess requirements on a patient-tailored follow-up procedure. However, the spiculation is also observed in some benign nodules, particularly in tuberculoma. The elucidation of the spliculation morphology in 3D thoracic CT images is an important preliminary step towards developing the malignant discrimination strategies from benign nodules. In this study, we present a visualization method to reveal a spatial configuration of spiculation of pulmonary nodules in three-dimensional thoracic CT images. Applying the method to an example of malignant nodule with the spiculated margins, the visualizing preliminary result of the spatial configuration reveals the presence of membrane structures of spiculation.

  9. High-Resolution 4D Imaging of Technetium Transport in Porous Media using Preclinical SPECT-CT

    NASA Astrophysics Data System (ADS)

    Dogan, M.; DeVol, T. A.; Groen, H.; Moysey, S. M.; Ramakers, R.; Powell, B. A.

    2015-12-01

    Preclinical SPECT-CT (single-photon emission computed tomography with integrated X-ray computed tomography) offers the potential to quantitatively image the dynamic three-dimensional distribution of radioisotopes with sub-millimeter resolution, overlaid with structural CT images (20-200 micron resolution), making this an attractive method for studying transport in porous media. A preclinical SPECT-CT system (U-SPECT4CT, MILabs BV. Utrecht, The Netherlands) was evaluated for imaging flow and transport of 99mTc (t1/2=6hrs) using a 46,5mm by 156,4mm column packed with individual layers consisting of <0.2mm diameter silica gel, 0.2-0.25, 0.5, 1.0, 2.0, 3.0, and 4.0mm diameter glass beads, and a natural soil sample obtained from the Savannah River Site. The column was saturated with water prior to injecting the 99mTc solution. During the injection the flow was interrupted intermittently for 10 minute periods to allow for the acquisition of a SPECT image of the transport front. Non-uniformity of the front was clearly observed in the images as well as the retarded movement of 99mTc in the soil layer. The latter is suggesting good potential for monitoring transport processes occurring on the timescale of hours. After breakthrough of 99mTc was achieved, the flow was stopped and SPECT data were collected in one hour increments to evaluate the sensitivity of the instrument as the isotope decayed. Fused SPECT- CT images allowed for improved interpretation of 99mTc distributions within individual pore spaces. With ~3 MBq remaining in the column, the lowest activity imaged, it was not possible to clearly discriminate any of the pore spaces.

  10. Toward time resolved 4D cardiac CT imaging with patient dose reduction: estimating the global heart motion

    NASA Astrophysics Data System (ADS)

    Taguchi, Katsuyuki; Segars, W. Paul; Fung, George S. K.; Tsui, Benjamin M. W.

    2006-03-01

    Coronary artery imaging with multi-slice helical computed tomography is a promising noninvasive imaging technique. The current major issues include the insufficient temporal resolution and large patient dose. We propose an image reconstruction method which provides a solution to both of the problems. The method uses an iterative approach repeating the following four steps until the difference between the two projection data sets falls below a certain criteria in step-4: 1) estimating or updating the cardiac motion vectors, 2) reconstructing the time-resolved 4D dynamic volume images using the motion vectors, 3) calculating the projection data from the current 4D images, 4) comparing them with the measured ones. In this study, we obtain the first estimate of the motion vector. We use the 4D NCAT phantom, a realistic computer model for the human anatomy and cardiac motions, to generate the dynamic fan-beam projection data sets as well to provide a known truth for the motion. Then, the halfscan reconstruction with the sliding time-window technique is used to generate cine images: f(t, r r). Here, we use one heart beat for each position r so that the time information is retained. Next, the magnitude of the first derivative of f(t, r r) with respect to time, i.e., |df/dt|, is calculated and summed over a region-of-interest (ROI), which is called the mean-absolute difference (MAD). The initial estimation of the vector field are obtained using MAD for each ROI. Results of the preliminary study are presented.

  11. Laboratory based study of dynamical processes by 4D X-ray CT with sub-second temporal resolution

    NASA Astrophysics Data System (ADS)

    Vavřík, D.; Jakůbek, J.; Kumpova, I.; Pichotka, M.

    2017-02-01

    There are numerous applications for which is advantageous to obtain X-ray transmission data necessary for 3D computed tomography (CT) within seconds or faster. The required high frame rates for data acquisition became available during the last decade due to intensive synchrotron radiation sources together with appropriate X-ray imaging detectors. It will be shown in this work that sub-second recording of the full CT data set can be reached even in laboratory conditions employing high power microfocus tubes together with a semiconductor pixelated detector. As an example, bubbles nucleation and evolution during dissolving of a pill in the water, releasing carbon dioxide will be shown in 3D with 2 Hz time resolution.

  12. SU-E-J-267: Weekly Volumetric and Dosimetric Changes in Adaptive Conformal Radiotherapy of Non-Small-Cell-Lung Cancer Using 4D CT and Gating

    SciTech Connect

    Li, Z; Shang, Q; Xiong, F; Zhang, X; Zhang, Q; Fu, S

    2014-06-01

    Purpose: This study was to evaluate the significance of weekly imageguided patient setup and to assess the volumetric and dosimetric changes in no-small-cell-lung cancer (NSCLC) patients treated with adaptive conformal radiotherapy (CRT). Methods: 9 NSCLC patients treated with 3D CRT underwent 4D CT-on-rail every five fractions. ITV was generated from three phases of the 4DCT (the end of exhalation, 25% before and after the end of exhalation). The margin of ITV to PTV is 5mm. 6 weekly CTs were acquired for each patient. The weekly CTs were fused with the planning CT by vertebrae. The couch shift was recorded for each weekly CT to evaluate the setup error. The gross tumor volumes (GTVs) were contoured on weekly CT images by a physician. Beams from the original plans were applied to weekly CTs to calculate the delivered doses. All patients underwent replanning after 20 fractions. Results: Among the total 54 CTs, the average setup error was 2.0± 1.7, 2.6± 2.1, 2.7± 2.2 mm in X, Y, and Z direction, respectively. The average volume of the primary GTV was reduced from 42.45 cc to 22.78 cc (47.04%) after 6 weeks. The maximal volume regression occurred between 15 and 20 fractions. Adaptive radiation therapy (ART) reduced the V20 and V5 of the lung by 33.5% and 16.89%, respectively. ART also reduced Dmean and D1/3 of the heart by 31.7% and 32.32%, respectively. Dmax of the spinal cord did not vary much during the treatment course. Conclusion: 5 mm margin is sufficient for 4D weekly CTguided radiotherapy in lung cancer. Tumor regression was observed in the majority of patients. ART significantly reduced the OARs dose. Our preliminary results indicated that an off-line ART approach is appropriate in clinical practice.

  13. Feasibility of quantitative lung perfusion by 4D CT imaging by a new dynamic-scanning protocol in an animal model

    NASA Astrophysics Data System (ADS)

    Wang, Yang; Goldin, Jonathan G.; Abtin, Fereidoun G.; Brown, Matt; McNitt-Gray, Mike

    2008-03-01

    The purpose of this study is to test a new dynamic Perfusion-CT imaging protocol in an animal model and investigate the feasibility of quantifying perfusion of lung parenchyma to perform functional analysis from 4D CT image data. A novel perfusion-CT protocol was designed with 25 scanning time points: the first at baseline and 24 scans after a bolus injection of contrast material. Post-contrast CT scanning images were acquired with a high sampling rate before the first blood recirculation and then a relatively low sampling rate until 10 minutes after administrating contrast agent. Lower radiation techniques were used to keep the radiation dose to an acceptable level. 2 Yorkshire swine with pulmonary emboli underwent this perfusion- CT protocol at suspended end inspiration. The software tools were designed to measure the quantitative perfusion parameters (perfusion, permeability, relative blood volume, blood flow, wash-in & wash-out enhancement) of voxel or interesting area of lung. The perfusion values were calculated for further lung functional analysis and presented visually as contrast enhancement maps for the volume being examined. The results show increased CT temporal sampling rate provides the feasibility of quantifying lung function and evaluating the pulmonary emboli. Differences between areas with known perfusion defects and those without perfusion defects were observed. In conclusion, the techniques to calculate the lung perfusion on animal model have potential application in human lung functional analysis such as evaluation of functional effects of pulmonary embolism. With further study, these techniques might be applicable in human lung parenchyma characterization and possibly for lung nodule characterization.

  14. Taking geoscience to the IMAX: 3D and 4D insight into geological processes using micro-CT

    NASA Astrophysics Data System (ADS)

    Dobson, Katherine; Dingwell, Don; Hess, Kai-Uwe; Withers, Philip; Lee, Peter; Pistone, Mattia; Fife, Julie; Atwood, Robert

    2015-04-01

    Geology is inherently dynamic, and full understanding of any geological system can only be achieved by considering the processes by which change occurs. Analytical limitations mean understanding has largely developed from ex situ analyses of the products of geological change, rather than of the processes themselves. Most methods essentially utilise "snap shot" sampling: and from thin section petrography to high resolution crystal chemical stratigraphy and field volcanology, we capture an incomplete view of a spatially and temporally variable system. Even with detailed experimental work, we can usually only analyse samples before and after we perform an experiment, as routine analysis methods are destructive. Serial sectioning and quenched experiments stopped at different stages can give some insight into the third and fourth dimension, but the true scaling of the processes from the laboratory to the 4D (3D + time) geosphere is still poorly understood. Micro computed tomography (XMT) can visualise the internal structures and spatial associations within geological samples non-destructively. With image resolutions of between 200 microns and 50 nanometres, tomography has the ability to provide a detailed sample assessment in 3D, and quantification of mineral associations, porosity, grain orientations, fracture alignments and many other features. This allows better understanding of the role of the complex geometries and associations within the samples, but the challenge of capturing the processes that generate and modify these structures remains. To capture processes, recent work has focused on developing experimental capability for in situ experiments on geological materials. Data presented will showcase examples from recent experiments where high speed synchrotron x-ray tomography has been used to acquire each 3D image in under 2 seconds. We present a suite of studies that showcase how it is now possible to take quantification of many geological processed into 3D and

  15. Tumor Tracking Method Based on a Deformable 4D CT Breathing Motion Model Driven by an External Surface Surrogate

    SciTech Connect

    Fassi, Aurora; Schaerer, Joël; Fernandes, Mathieu; Riboldi, Marco; Sarrut, David; Baroni, Guido

    2014-01-01

    Purpose: To develop a tumor tracking method based on a surrogate-driven motion model, which provides noninvasive dynamic localization of extracranial targets for the compensation of respiration-induced intrafraction motion in high-precision radiation therapy. Methods and Materials: The proposed approach is based on a patient-specific breathing motion model, derived a priori from 4-dimensional planning computed tomography (CT) images. Model parameters (respiratory baseline, amplitude, and phase) are retrieved and updated at each treatment fraction according to in-room radiography acquisition and optical surface imaging. The baseline parameter is adapted to the interfraction variations obtained from the daily cone beam (CB) CT scan. The respiratory amplitude and phase are extracted from an external breathing surrogate, estimated from the displacement of the patient thoracoabdominal surface, acquired with a noninvasive surface imaging device. The developed method was tested on a database of 7 lung cancer patients, including the synchronized information on internal and external respiratory motion during a CBCT scan. Results: About 30 seconds of simultaneous acquisition of CBCT and optical surface images were analyzed for each patient. The tumor trajectories identified in CBCT projections were used as reference and compared with the target trajectories estimated from surface displacement with the a priori motion model. The resulting absolute differences between the reference and estimated tumor motion along the 2 image dimensions ranged between 0.7 and 2.4 mm; the measured phase shifts did not exceed 7% of the breathing cycle length. Conclusions: We investigated a tumor tracking method that integrates breathing motion information provided by the 4-dimensional planning CT with surface imaging at the time of treatment, representing an alternative approach to point-based external–internal correlation models. Although an in-room radiograph-based assessment of the

  16. An automated landmark-based elastic registration technique for large deformation recovery from 4-D CT lung images

    NASA Astrophysics Data System (ADS)

    Negahdar, Mohammadreza; Zacarias, Albert; Milam, Rebecca A.; Dunlap, Neal; Woo, Shiao Y.; Amini, Amir A.

    2012-03-01

    The treatment plan evaluation for lung cancer patients involves pre-treatment and post-treatment volume CT imaging of the lung. However, treatment of the tumor volume lung results in structural changes to the lung during the course of treatment. In order to register the pre-treatment volume to post-treatment volume, there is a need to find robust and homologous features which are not affected by the radiation treatment along with a smooth deformation field. Since airways are well-distributed in the entire lung, in this paper, we propose use of airway tree bifurcations for registration of the pre-treatment volume to the post-treatment volume. A dedicated and automated algorithm has been developed that finds corresponding airway bifurcations in both images. To derive the 3-D deformation field, a B-spline transformation model guided by mutual information similarity metric was used to guarantee the smoothness of the transformation while combining global information from bifurcation points. Therefore, the approach combines both global statistical intensity information with local image feature information. Since during normal breathing, the lung undergoes large nonlinear deformations, it is expected that the proposed method would also be applicable to large deformation registration between maximum inhale and maximum exhale images in the same subject. The method has been evaluated by registering 3-D CT volumes at maximum exhale data to all the other temporal volumes in the POPI-model data.

  17. SU-D-201-07: Exploring the Utility of 4D FDG-PET/CT Scans in Design of Radiation Therapy Planning Compared with 3D PET/CT: A Prospective Study

    SciTech Connect

    Ma, C; Yin, Y

    2015-06-15

    Purpose: A method using four-dimensional(4D) PET/CT in design of radiation treatment planning was proposed and the target volume and radiation dose distribution changes relative to standard three-dimensional (3D) PET/CT were examined. Methods: A target deformable registration method was used by which the whole patient’s respiration process was considered and the effect of respiration motion was minimized when designing radiotherapy planning. The gross tumor volume of a non-small-cell lung cancer was contoured on the 4D FDG-PET/CT and 3D PET/CT scans by use of two different techniques: manual contouring by an experienced radiation oncologist using a predetermined protocol; another technique using a constant threshold of standardized uptake value (SUV) greater than 2.5. The target volume and radiotherapy dose distribution between VOL3D and VOL4D were analyzed. Results: For all phases, the average automatic and manually GTV volume was 18.61 cm3 (range, 16.39–22.03 cm3) and 31.29 cm3 (range, 30.11–35.55 cm3), respectively. The automatic and manually volume of merged IGTV were 27.82 cm3 and 49.37 cm3, respectively. For the manual contour, compared to 3D plan the mean dose for the left, right, and total lung of 4D plan have an average decrease 21.55%, 15.17% and 15.86%, respectively. The maximum dose of spinal cord has an average decrease 2.35%. For the automatic contour, the mean dose for the left, right, and total lung have an average decrease 23.48%, 16.84% and 17.44%, respectively. The maximum dose of spinal cord has an average decrease 1.68%. Conclusion: In comparison to 3D PET/CT, 4D PET/CT may better define the extent of moving tumors and reduce the contouring tumor volume thereby optimize radiation treatment planning for lung tumors.

  18. SU-D-17A-03: 5D Respiratory Motion Model Based Iterative Reconstruction Method for 4D Cone-Beam CT

    SciTech Connect

    Gao, Y; Thomas, D; Low, D; Gao, H

    2014-06-01

    Purpose: The purpose of this work is to develop a new iterative reconstruction method for 4D cone-beam CT (CBCT) based on a published time-independent 5D respiratory motion model. The proposed method will offer a single high-resolution image at a user-selected breathing phase and the 5D motion model parameters, which could be used to generate the breathing pattern during the CT acquisition. Methods: 5D respiratory motion model was proposed for accurately modeling the motion of lung and lung tumor tissues. 4D images are then parameterized by a reference image, measured breathing amplitude, breathing rate, two time-independent vector fields that describe the 5D model parameters, and a scalar field that describes the change in HU as a function of breathing amplitude. In contrast with the traditional method of reconstructing multiple temporal image phases to reduce respiratory artifact, 5D model based method simplify the problem into the reconstruction of a single reference image and the 5D motion model parameters. The reconstruction formulation of the reference image and scalar and vector fields is a nonlinear least-square optimization problem that consists of solving the reference image and fields alternately, in which the reference image is regularized with the total variation sparsity transform and the vector fields are solved through linearizations regularized by the H1 norm. 2D lung simulations were performed in this proof-of-concept study. Results: The breathing amplitude, its rate, and the corresponding scalar and vector fields were generated from a patient case. Compared with filtered backprojection method and sparsity regularized iterative method for the phase-by-phase reconstruction, the proposed 5D motion model based method yielded improved image quality. Conclusion: Based on 5D respiratory motion model, we have developed a new iterative reconstruction method for 4D CBCT that has the potential for improving image quality while providing needed on

  19. Analysis of the variability among radiation oncologists in delineation of the postsurgical tumor bed based on 4D-CT

    PubMed Central

    Wang, Wei; Li, Jianbin; Xing, Jun; Xu, Min; Shao, Qian; Fan, Tingyong; Guo, Bing; Liu, Shanshan

    2016-01-01

    Objective This study investigated interobserver and intraobserver variability in radiation oncologists' definition of the tumor bed (TB) after breast-conserving surgery (BCS). Results The TB volume, CVS and number of surgical clips were not significantly related to intraobserver variability. Moreover, no correlation was noted between CT slice thickness and interobserver variability (Δinter, DSCinter) in TB delineation, and no significant difference was noted among the three groups. The TB volume was negatively correlated with Δinter. DSCinter improved significantly with increased TB volume and decreased Δinter. DSCinter also increased significantly in patients with a CVS of 3 to 5 compared with patients with a CVS of 1 to 2. DSCinter was thus positively correlated with the CVS, with a correlation coefficient of 0.451. The use of 7 to 9 surgical clips neither decreased Δinter nor increased DSCinter. Materials and Methods Five or more surgical clips were placed at the TB during lumpectomy. The TB was delineated on the end expiration scan. The data were stratified based on the cavity visualization score (CVS), CT slice thickness and surgical clip number. The Dice similarity coefficient (DSC) and inter(intra)observer variability (Δinter and Δintra) in different groups were evaluated and compared. Conclusions Inter(intra)observer variability in TB delineation was decreased for breast cancer patients implanted with 5 or more surgical clips in the cohort with a higher CVS and a larger TB. The use of more than 6 surgical clips did not significantly improve TB delineation, so 5 to 6 surgical clips are likely adequate to delineate the TB. PMID:27655639

  20. Assessing cardiac function from total-variation-regularized 4D C-arm CT in the presence of angular undersampling

    NASA Astrophysics Data System (ADS)

    Taubmann, O.; Haase, V.; Lauritsch, G.; Zheng, Y.; Krings, G.; Hornegger, J.; Maier, A.

    2017-04-01

    Time-resolved tomographic cardiac imaging using an angiographic C-arm device may support clinicians during minimally invasive therapy by enabling a thorough analysis of the heart function directly in the catheter laboratory. However, clinically feasible acquisition protocols entail a highly challenging reconstruction problem which suffers from sparse angular sampling of the trajectory. Compressed sensing theory promises that useful images can be recovered despite massive undersampling by means of sparsity-based regularization. For a multitude of reasons—most notably the desired reduction of scan time, dose and contrast agent required—it is of great interest to know just how little data is actually sufficient for a certain task. In this work, we apply a convex optimization approach based on primal-dual splitting to 4D cardiac C-arm computed tomography. We examine how the quality of spatially and temporally total-variation-regularized reconstruction degrades when using as few as 6.9+/- 1.2 projection views per heart phase. First, feasible regularization weights are determined in a numerical phantom study, demonstrating the individual benefits of both regularizers. Secondly, a task-based evaluation is performed in eight clinical patients. Semi-automatic segmentation-based volume measurements of the left ventricular blood pool performed on strongly undersampled images show a correlation of close to 99% with measurements obtained from less sparsely sampled data.

  1. Assessing cardiac function from total-variation-regularized 4-D C-arm CT in the presence of angular undersampling.

    PubMed

    Taubmann, Oliver; Haase, Viktor; Lauritsch, Guenter; Zheng, Yefeng; Krings, Gregor; Hornegger, Joachim; Maier, Andreas

    2017-02-22

    Time-resolved tomographic cardiac imaging using an angiographic C-arm device may support clinicians during minimally invasive therapy by enabling a thorough analysis of the heart function directly in the catheter laboratory. However, clinically feasible acquisition protocols entail a highly challenging reconstruction problem which suffers from sparse angular sampling of the trajectory. Compressed sensing theory promises that useful images can be recovered despite massive undersampling by means of sparsity-based regularization. For a multitude of reasons-most notably the desired reduction of scan time, dose and contrast agent required-it is of great interest to know just how little data is actually sufficient for a certain task. In this work, we apply a convex optimization approach based on primal-dual splitting to 4-D cardiac C-arm computed tomography. We examine how the quality of spatially and temporally total-variation-regularized reconstruction degrades when using as few as 6.9 ± 1.2 projection views per heart phase. First, feasible regularization weights are determined in a numerical phantom study, demonstrating the individual benefits of both regularizers. Secondly, a task-based evaluation is performed in eight clinical patients. Semi-automatic segmentation-based volume measurements of the left ventricular blood pool performed on strongly undersampled images show a correlation of close to 99% with measurements obtained from less sparsely sampled data.

  2. Emphysema on Thoracic CT and Exercise Ventilatory Inefficiency in Mild-to-Moderate COPD.

    PubMed

    Jones, Joshua H; Zelt, Joel T; Hirai, Daniel M; Diniz, Camilla V; Zaza, Aida; O'Donnell, Denis E; Neder, J Alberto

    2017-04-01

    There is growing evidence that emphysema on thoracic computed tomography (CT) is associated with poor exercise tolerance in COPD patients with only mild-to-moderate airflow obstruction. We hypothesized that an excessive ventilatory response to exercise (ventilatory inefficiency) would underlie these abnormalities. In a prospective study, 19 patients (FEV1 = 82 ± 13%, 12 Global Initiative for Chronic Obstructive Lung Disease (GOLD) stage 1) and 26 controls underwent an incremental exercise test. Ventilatory inefficiency was assessed by the ventilation ([Formula: see text]E)/CO2 output ([Formula: see text]CO2) nadir. Pulmonary blood flow (PBF) in a submaximal test was calculated by inert gas rebreathing. Emphysema was quantified as % of attenuation areas below 950 HU. Patients typically presented with centrilobular emphysema (76.8 ± 10.1% of total emphysema) in the upper lobes (upper/total lung ratio = 0.82 ± 0.04). They had lower peak oxygen uptake ([Formula: see text]O2), higher [Formula: see text]E/[Formula: see text]CO2 nadir, and greater dyspnea scores than controls (p < 0.05). Lower peak [Formula: see text]O2 and worse dyspnea were found in patients with higher [Formula: see text]E/[Formula: see text]CO2 nadirs (≥30). Patients had blunted increases in PBF from rest to iso-[Formula: see text]O2 exercise (p < 0.05). Higher [Formula: see text]E/[Formula: see text]CO2 nadir in COPD was associated with emphysema severity (r = 0.63) which, in turn, was related to reduced lung diffusing capacity (r = -0.72) and blunted changes in PBF from rest to exercise (r = -0.69) (p < 0.01). Ventilation "wasted" in emphysematous areas is associated with impaired exercise ventilatory efficiency in mild-to-moderate COPD. Exercise ventilatory inefficiency links structure (emphysema) and function (DLCO) to a key clinical outcome (poor exercise tolerance) in COPD patients with only modest spirometric abnormalities.

  3. A Novel Assessment of Various Bio-Imaging Methods for Lung Tumor Detection and Treatment by using 4-D and 2-D CT Images

    PubMed Central

    Judice A., Antony; Geetha, Dr. K. Parimala

    2013-01-01

    Lung Cancer is known as one of the most difficult cancer to cure, and the number of deaths that it causes generally increasing. A detection of the Lung Cancer in its early stage can be helpful for Medical treatment to limit the danger, but it is a challenging problem due to Cancer cell structure. Interpretation of Medical image is often difficult and time consuming, even for the experienced Physicians. The aid of image analysis Based on machine learning can make this process easier. This paper describes fully Automatic Decision Support system for Lung Cancer diagnostic from CT Lung images. Most traditional medical diagnosis systems are founded on huge quantity of training data and takes long processing time. However, on the occasion that very little volume of data is available, the traditional diagnosis systems derive defects such as larger error, Time complexity. Focused on the solution to this problem, a Medical Diagnosis System based on Hidden Markov Model (HMM) is presented. In this paper we describe a pre-processing stage involving some Noise removal techniques help to solve this problem, we preprocess an images (by Mean Error Square Filtering and Histogram analysis)obtained after scanning the Lung CT images. Secondly separate the lung areas from an image by a segmentation process (by Thresholding and region growing techniques). Finally we developed HMM for the classification of Cancer Nodule. Results are checked for 2D and 4D CT images. This automation process reduces the time complexity and increases the diagnosis confidence. PMID:23847454

  4. Determination of prospective displacement-based gate threshold for respiratory-gated radiation delivery from retrospective phase-based gate threshold selected at 4D CT simulation

    SciTech Connect

    Vedam, S.; Archambault, L.; Starkschall, G.; Mohan, R.; Beddar, S.

    2007-11-15

    Four-dimensional (4D) computed tomography (CT) imaging has found increasing importance in the localization of tumor and surrounding normal structures throughout the respiratory cycle. Based on such tumor motion information, it is possible to identify the appropriate phase interval for respiratory gated treatment planning and delivery. Such a gating phase interval is determined retrospectively based on tumor motion from internal tumor displacement. However, respiratory-gated treatment is delivered prospectively based on motion determined predominantly from an external monitor. Therefore, the simulation gate threshold determined from the retrospective phase interval selected for gating at 4D CT simulation may not correspond to the delivery gate threshold that is determined from the prospective external monitor displacement at treatment delivery. The purpose of the present work is to establish a relationship between the thresholds for respiratory gating determined at CT simulation and treatment delivery, respectively. One hundred fifty external respiratory motion traces, from 90 patients, with and without audio-visual biofeedback, are analyzed. Two respiratory phase intervals, 40%-60% and 30%-70%, are chosen for respiratory gating from the 4D CT-derived tumor motion trajectory. From residual tumor displacements within each such gating phase interval, a simulation gate threshold is defined based on (a) the average and (b) the maximum respiratory displacement within the phase interval. The duty cycle for prospective gated delivery is estimated from the proportion of external monitor displacement data points within both the selected phase interval and the simulation gate threshold. The delivery gate threshold is then determined iteratively to match the above determined duty cycle. The magnitude of the difference between such gate thresholds determined at simulation and treatment delivery is quantified in each case. Phantom motion tests yielded coincidence of simulation

  5. WE-AB-303-05: Breathing Motion of Liver Segments From Fiducial Tracking During Robotic Radiosurgery and Comparison with 4D-CT-Derived Fiducial Motion

    SciTech Connect

    Sutherland, J; Pantarotto, J; Nair, V; Cook, G; Plourde, M; Vandervoort, E

    2015-06-15

    Purpose: To quantify respiratory-induced motion of liver segments using the positions of implanted fiducials during robotic radiosurgery. This study also compared fiducial motion derived from four-dimensional computed tomography (4D-CT) maximum intensity projections (MIP) with motion derived from imaging during treatment. Methods: Forty-two consecutive liver patients treated with liver ablative radiotherapy were accrued to an ethics approved retrospective study. The liver segment in which each fiducial resided was identified. Fiducial positions throughout each treatment fraction were determined using orthogonal kilovoltage images. Any data due to patient repositioning or motion was removed. Mean fiducial positions were calculated. Fiducial positions beyond two standard deviations of the mean were discarded and remaining positions were fit to a line segment using least squares minimization (LSM). For eight patients, fiducial motion was derived from 4D-CT MIPs by calculating the CT number weighted mean position of the fiducial on each slice and fitting a line segment to these points using LSM. Treatment derived fiducial trajectories were corrected for patient rotation and compared to MIP derived trajectories. Results: The mean total magnitude of fiducial motion across all liver segments in left-right, anteroposterior, and superoinferior (SI) directions were 3.0 ± 0.2 mm, 9.3 ± 0.4 mm, and 20.5 ± 0.5 mm, respectively. Differences in per-segment mean fiducial motion were found with SI motion ranging from 12.6 ± 0.8 mm to 22.6 ± 0.9 mm for segments 3 and 8, respectively. Large, varied differences between treatment and MIP derived motion at simulation were found with the mean difference for SI motion being 2.6 mm (10.8 mm standard deviation). Conclusion: The magnitude of liver fiducial motion was found to differ by liver segment. MIP derived liver fiducial motion differed from motion observed during treatment, implying that 4D-CTs may not accurately capture the

  6. Automated detection and quantification of micronodules in thoracic CT scans to identify subjects at risk for silicosis

    NASA Astrophysics Data System (ADS)

    Jacobs, C.; Opdam, S. H. T. T.; van Rikxoort, E. M.; Mets, O. M.; Rooyackers, J.; de Jong, P. A.; Prokop, M.; van Ginneken, B.

    2014-03-01

    Silica dust-exposed individuals are at high risk of developing silicosis, a fatal and incurable lung disease. The presence of disseminated micronodules on thoracic CT is the radiological hallmark of silicosis but locating micronodules, to identify subjects at risk, is tedious for human observers. We present a computer-aided detection scheme to automatically find micronodules and quantify micronodule load. The system used lung segmentation, template matching, and a supervised classification scheme. The system achieved a promising sensitivity of 84% at an average of 8.4 false positive marks per scan. In an independent data set of 54 CT scans in which we defined four risk categories, the CAD system automatically classified 83% of subjects correctly, and obtained a weighted kappa of 0.76.

  7. Thoracic cavity segmentation algorithm using multiorgan extraction and surface fitting in volumetric CT

    SciTech Connect

    Bae, JangPyo; Kim, Namkug Lee, Sang Min; Seo, Joon Beom; Kim, Hee Chan

    2014-04-15

    Purpose: To develop and validate a semiautomatic segmentation method for thoracic cavity volumetry and mediastinum fat quantification of patients with chronic obstructive pulmonary disease. Methods: The thoracic cavity region was separated by segmenting multiorgans, namely, the rib, lung, heart, and diaphragm. To encompass various lung disease-induced variations, the inner thoracic wall and diaphragm were modeled by using a three-dimensional surface-fitting method. To improve the accuracy of the diaphragm surface model, the heart and its surrounding tissue were segmented by a two-stage level set method using a shape prior. To assess the accuracy of the proposed algorithm, the algorithm results of 50 patients were compared to the manual segmentation results of two experts with more than 5 years of experience (these manual results were confirmed by an expert thoracic radiologist). The proposed method was also compared to three state-of-the-art segmentation methods. The metrics used to evaluate segmentation accuracy were volumetric overlap ratio (VOR), false positive ratio on VOR (FPRV), false negative ratio on VOR (FNRV), average symmetric absolute surface distance (ASASD), average symmetric squared surface distance (ASSSD), and maximum symmetric surface distance (MSSD). Results: In terms of thoracic cavity volumetry, the mean ± SD VOR, FPRV, and FNRV of the proposed method were (98.17 ± 0.84)%, (0.49 ± 0.23)%, and (1.34 ± 0.83)%, respectively. The ASASD, ASSSD, and MSSD for the thoracic wall were 0.28 ± 0.12, 1.28 ± 0.53, and 23.91 ± 7.64 mm, respectively. The ASASD, ASSSD, and MSSD for the diaphragm surface were 1.73 ± 0.91, 3.92 ± 1.68, and 27.80 ± 10.63 mm, respectively. The proposed method performed significantly better than the other three methods in terms of VOR, ASASD, and ASSSD. Conclusions: The proposed semiautomatic thoracic cavity segmentation method, which extracts multiple organs (namely, the rib, thoracic wall, diaphragm, and heart

  8. Segmenting the thoracic, abdominal and pelvic musculature on CT scans combining atlas-based model and active contour model

    NASA Astrophysics Data System (ADS)

    Zhang, Weidong; Liu, Jiamin; Yao, Jianhua; Summers, Ronald M.

    2013-03-01

    Segmentation of the musculature is very important for accurate organ segmentation, analysis of body composition, and localization of tumors in the muscle. In research fields of computer assisted surgery and computer-aided diagnosis (CAD), muscle segmentation in CT images is a necessary pre-processing step. This task is particularly challenging due to the large variability in muscle structure and the overlap in intensity between muscle and internal organs. This problem has not been solved completely, especially for all of thoracic, abdominal and pelvic regions. We propose an automated system to segment the musculature on CT scans. The method combines an atlas-based model, an active contour model and prior segmentation of fat and bones. First, body contour, fat and bones are segmented using existing methods. Second, atlas-based models are pre-defined using anatomic knowledge at multiple key positions in the body to handle the large variability in muscle shape. Third, the atlas model is refined using active contour models (ACM) that are constrained using the pre-segmented bone and fat. Before refining using ACM, the initialized atlas model of next slice is updated using previous atlas. The muscle is segmented using threshold and smoothed in 3D volume space. Thoracic, abdominal and pelvic CT scans were used to evaluate our method, and five key position slices for each case were selected and manually labeled as the reference. Compared with the reference ground truth, the overlap ratio of true positives is 91.1%+/-3.5%, and that of false positives is 5.5%+/-4.2%.

  9. Monitoring in vivo (re)modeling: a computational approach using 4D microCT data to quantify bone surface movements.

    PubMed

    Birkhold, Annette I; Razi, Hajar; Weinkamer, Richard; Duda, Georg N; Checa, Sara; Willie, Bettina M

    2015-06-01

    Bone undergoes continual damage repair and structural adaptation to changing external loads with the aim of maintaining skeletal integrity throughout life. The ability to monitor bone (re)modeling would allow for a better understanding in how various pathologies and interventions affect bone turnover and subsequent bone strength. To date, however, current methods to monitor bone (re)modeling over time and in space are limited. We propose a novel method to visualize and quantify bone turnover, based on in vivo microCT imaging and a 4D computational approach. By in vivo tracking of spatially correlated formation and resorption sites over time it classifies bone restructuring into (re)modeling sequences, the spatially and temporally linked sequences of formation, resorption and quiescent periods on the bone surface. The microCT based method was validated using experimental data from an in vivo mouse tibial loading model and ex vivo data of the mouse tibia. In this application, the method allows the visualization of time-resolved cortical (re)modeling and the quantification of short-term and long-term modeling on the endocortical and periosteal surface at the mid-diaphysis of loaded and control mice tibiae. Both short-term and long-term modeling processes, independent formation and resorption events, could be monitored and modeling (spatially not correlated formation and resorption) and remodeling (resorption followed by new formation at the same site) could be distinguished on the bone surface. This novel method that combines in vivo microCT with a computational approach is a powerful tool to monitor bone turnover in animal models now and is waiting to be applied to human patients in the near future.

  10. Thoracic Temporal Subtraction Three Dimensional Computed Tomography (3D-CT): Screening for Vertebral Metastases of Primary Lung Cancers

    PubMed Central

    Iwano, Shingo; Ito, Rintaro; Umakoshi, Hiroyasu; Karino, Takatoshi; Inoue, Tsutomu; Li, Yuanzhong; Naganawa, Shinji

    2017-01-01

    Purpose We developed an original, computer-aided diagnosis (CAD) software that subtracts the initial thoracic vertebral three-dimensional computed tomography (3D-CT) image from the follow-up 3D-CT image. The aim of this study was to investigate the efficacy of this CAD software during screening for vertebral metastases on follow-up CT images of primary lung cancer patients. Materials and Methods The interpretation experiment included 30 sets of follow-up CT scans in primary lung cancer patients and was performed by two readers (readers A and B), who each had 2.5 years’ experience reading CT images. In 395 vertebrae from C6 to L3, 46 vertebral metastases were identified as follows: osteolytic metastases (n = 17), osteoblastic metastases (n = 14), combined osteolytic and osteoblastic metastases (n = 6), and pathological fractures (n = 9). Thirty-six lesions were in the anterior component (vertebral body), and 10 lesions were in the posterior component (vertebral arch, transverse process, and spinous process). The area under the curve (AUC) by receiver operating characteristic (ROC) curve analysis and the sensitivity and specificity for detecting vertebral metastases were compared with and without CAD for each observer. Results Reader A detected 47 abnormalities on CT images without CAD, and 33 of them were true-positive metastatic lesions. Using CAD, reader A detected 57 abnormalities, and 38 were true positives. The sensitivity increased from 0.717 to 0.826, and on ROC curve analysis, AUC with CAD was significantly higher than that without CAD (0.849 vs. 0.902, p = 0.021). Reader B detected 40 abnormalities on CT images without CAD, and 36 of them were true-positive metastatic lesions. Using CAD, reader B detected 44 abnormalities, and 39 were true positives. The sensitivity increased from 0.783 to 0.848, and AUC with CAD was nonsignificantly higher than that without CAD (0.889 vs. 0.910, p = 0.341). Both readers detected more osteolytic and osteoblastic

  11. Computerized lung nodule detection on thoracic CT images: combined rule-based and statistical classifier for false-positive reduction

    NASA Astrophysics Data System (ADS)

    Gurcan, Metin N.; Petrick, Nicholas; Sahiner, Berkman; Chan, Heang-Ping; Cascade, Philip N.; Kazerooni, Ella A.; Hadjiiski, Lubomir M.

    2001-07-01

    We are developing a computer-aided diagnosis (CAD) system for lung nodule detection on thoracic helical computed tomography (CT) images. In the first stage of this CAD system, lung regions are identified and suspicious structures are segmented. These structures may include true lung nodules or normal structures that consist mainly of vascular structures. We have designed rule-based classifiers to distinguish nodules and normal structures using 2D and 3D features. After rule-based classification, linear discriminant analysis (LDA) is used to further reduce the number of false positive (FP) objects. We have performed a preliminary study using CT images from 17 patients with 31 lung nodules. When only LDA classification was applied to the segmented objects, the sensitivity was 84% (26/31) with 2.53 (1549/612) FP objects per slice. When the LDA followed the rule-based classifier, the number of FP objects per slice decreased to 1.75 (1072/612) at the same sensitivity. These preliminary results demonstrate the feasibility of our approach for nodule detection and FP reduction on CT images. The inclusion of rule-based classification leads to an improvement in detection accuracy for the CAD system.

  12. Comparative analysis of the patency of the internal thoracic artery in the CABG of left anterior descending artery: 6-month postoperative coronary CT angiography evaluation

    PubMed Central

    Deininger, Maurilio Onofre; Moreira, Luiz Felipe Pinho; Dallan, Luiz Alberto Oliveira; de Oliveira, Orlando Gomes; Magalhães, Daniel Marcelo Silva; Coelho, José Reinaldo de Moura; Deininger, Eugênia di Giuseppe; Lopes, Norland de Souza; Queiroga, Ricardo Wanderley; Belmont, Elizabeth Ferreira

    2014-01-01

    Objective To assess the patency of the pedicled right internal thoracic artery with an anteroaortic course and compare it to the patency of the left internal thoracic artery , in anastomosis to the left anterior descending artery in coronary artery bypass grafting by using coronary CT angiography at 6 months postoperatively. Methods Between December 2008 and December 2011, 100 patients were selected to undergo a prospective coronary artery bypass grafting procedure without cardiopulmonary bypass. The patients were randomly divided by a computer-generated list into Group-1 (G-1) and Group-2 (G-2), comprising 50 patients each, the technique used was known at the beginning of the surgery. In G-1, coronary artery bypass grafting was performed using the left internal thoracic artery for the left anterior descending and the free right internal thoracic artery for the circumflex, and in G-2, coronary artery bypass grafting was performed using the right internal thoracic artery pedicled to the left anterior descending and the left internal thoracic artery pedicled to the circumflex territory. Results The groups were similar with regard to the preoperative clinical data. A male predominance of 75.6% and 88% was observed in G-1 and G-2, respectively. Five patients migrated from G-1 to G-2 because of atheromatous disease in the ascending aorta. The average number of distal anastomoses was 3.48 (SD=0.72) in G-1 and 3.20 (SD=0.76) in G-2. Coronary CT angiography in 96 re-evaluated patients showed that all ITAs, right or left, used in situ for the left anterior descending were patent. There were no deaths in either group. Conclusion Coronary artery bypass grafting surgery involving anastomosis of the anteroaortic right internal thoracic artery to the left anterior descending artery has an outcome similar to that obtained using the left internal thoracic artery for the same coronary site. PMID:25140469

  13. Algorithm of pulmonary emphysema extraction using thoracic 3-D CT images

    NASA Astrophysics Data System (ADS)

    Saita, Shinsuke; Kubo, Mitsuru; Kawata, Yoshiki; Niki, Noboru; Nakano, Yasutaka; Ohmatsu, Hironobu; Tominaga, Keigo; Eguchi, Kenji; Moriyama, Noriyuki

    2008-03-01

    Emphysema patients have the tendency to increase due to aging and smoking. Emphysematous disease destroys alveolus and to repair is impossible, thus early detection is essential. CT value of lung tissue decreases due to the destruction of lung structure. This CT value becomes lower than the normal lung- low density absorption region or referred to as Low Attenuation Area (LAA). So far, the conventional way of extracting LAA by simple thresholding has been proposed. However, the CT value of CT image fluctuates due to the measurement conditions, with various bias components such as inspiration, expiration and congestion. It is therefore necessary to consider these bias components in the extraction of LAA. We removed these bias components and we proposed LAA extraction algorithm. This algorithm has been applied to the phantom image. Then, by using the low dose CT(normal: 30 cases, obstructive lung disease: 26 cases), we extracted early stage LAA and quantitatively analyzed lung lobes using lung structure.

  14. Hybrid registration of PET/CT in thoracic region with pre-filtering PET sinogram

    NASA Astrophysics Data System (ADS)

    Mokri, S. S.; Saripan, M. I.; Marhaban, M. H.; Nordin, A. J.; Hashim, S.

    2015-11-01

    The integration of physiological (PET) and anatomical (CT) images in cancer delineation requires an accurate spatial registration technique. Although hybrid PET/CT scanner is used to co-register these images, significant misregistrations exist due to patient and respiratory/cardiac motions. This paper proposes a hybrid feature-intensity based registration technique for hybrid PET/CT scanner. First, simulated PET sinogram was filtered with a 3D hybrid mean-median before reconstructing the image. The features were then derived from the segmented structures (lung, heart and tumor) from both images. The registration was performed based on modified multi-modality demon registration with multiresolution scheme. Apart from visual observations improvements, the proposed registration technique increased the normalized mutual information index (NMI) between the PET/CT images after registration. All nine tested datasets show marked improvements in mutual information (MI) index than free form deformation (FFD) registration technique with the highest MI increase is 25%.

  15. False-positive reduction using Hessian features in computer-aided detection of pulmonary nodules on thoracic CT images

    NASA Astrophysics Data System (ADS)

    Sahiner, Berkman; Ge, Zhanyu; Chan, Heang-Ping; Hadjiiski, Lubomir M.; Bogot, Naama; Cascade, Philip N.; Kazerooni, Ella A.

    2005-04-01

    We are developing a computer-aided detection (CAD) system for lung nodules in thoracic CT volumes. During false positive (FP) reduction, the image structures around the identified nodule candidates play an important role in differentiating nodules from vessels. In our previous work, we exploited shape and first-order derivative information of the images by extracting ellipsoid and gradient field features. The purpose of this study was to explore the object shape information using second-order derivatives and the Hessian matrix to further improve the performance of our detection system. Eight features related to the eigenvalues of the Hessian matrix were extracted from a volume of interest containing the object, and were combined with ellipsoid and gradient field features to discriminate nodules from FPs. A data set of 82 CT scans from 56 patients was used to evaluate the usefulness of the FP reduction technique. The classification accuracy was assessed using the area Az under the receiving operating characteristic curve and the number of FPs per section at 80% sensitivity. In the combined feature space, we obtained a test Az of 0.97 +/- 0.01, and 0.27 FPs/section at 80% sensitivity. Our results indicate that combining the Hessian, ellipsoid and gradient field features can significantly improve the performance of our FP reduction stage.

  16. A novel spherical shell filter for reducing false positives in automatic detection of pulmonary nodules in thoracic CT scans

    NASA Astrophysics Data System (ADS)

    van de Leemput, Sil; Dorssers, Frank; Ehteshami Bejnordi, Babak

    2015-03-01

    Early detection of pulmonary nodules is crucial for improving prognosis of patients with lung cancer. Computer-aided detection of lung nodules in thoracic computed tomography (CT) scans has a great potential to enhance the performance of the radiologist in detecting nodules. In this paper we present a computer-aided lung nodule detection system for computed tomography (CT) scans that works in three steps. The system first segments the lung using thresholding and hole filling. From this segmentation the system extracts candidate nodules using Laplacian of Gaussian. To reject false positives among the detected candidate nodules, multiple established features are calculated. We propose a novel feature based on a spherical shell filter, which is specifically designed to distinguish between vascular structures and nodular structures. The performance of the proposed CAD system was evaluated by partaking in the ANODE09 challenge, which presents a platform for comparing automatic nodule detection programs. The results from the challenge show that our CAD system ranks third among the submitted works, demonstrating the efficacy of our proposed CAD system. The results also show that our proposed spherical shell filter in combination with conventional features can significantly reduce the number of false positives from the detected candidate nodules.

  17. Fuzzy Clustering Applied to ROI Detection in Helical Thoracic CT Scans with a New Proposal and Variants

    PubMed Central

    Castro, Alfonso; Boveda, Carmen; Arcay, Bernardino; Sanjurjo, Pedro

    2016-01-01

    The detection of pulmonary nodules is one of the most studied problems in the field of medical image analysis due to the great difficulty in the early detection of such nodules and their social impact. The traditional approach involves the development of a multistage CAD system capable of informing the radiologist of the presence or absence of nodules. One stage in such systems is the detection of ROI (regions of interest) that may be nodules in order to reduce the space of the problem. This paper evaluates fuzzy clustering algorithms that employ different classification strategies to achieve this goal. After characterising these algorithms, the authors propose a new algorithm and different variations to improve the results obtained initially. Finally it is shown as the most recent developments in fuzzy clustering are able to detect regions that may be nodules in CT studies. The algorithms were evaluated using helical thoracic CT scans obtained from the database of the LIDC (Lung Image Database Consortium). PMID:27517049

  18. CT findings of a thoracic vertebral hemangioma presenting with acute neurological symptoms.

    PubMed

    Tan, Sinan; Kurt, Aydın; Okutan, Ozerk; Keskin, Suat

    2011-01-01

    Vertebral body hemangiomas are benign lesions and account for 4% of all spinal tumors. The most common histological type is cavernous hemangioma. These tumors generally locate in the vertebral body as a solitary lesion. Multiple lesions are seen in approximately 25-30% of vertebral hemangiomas. Mostly they are asymptomatic and incidentally found with radiological studies. Symptomatic vertebral hemangiomas are rare and represent < 1% of all hemangiomas; however, if untreated, they may cause local or radicular pain and neurological deficits ranging from myeloradiculopathy to paralysis. In this case we aim to present preoperative and postoperative Computed Tomography findings of a cavernous hemangioma that caused sudden motor deficit and was localised to the thoracic vertebra corpus and posterior elements.

  19. TU-F-BRF-07: Accuracy of Routine Treatment Planning 4D and DIBH CT Delineation of the Left Anterior Descending Artery in Radiotherapy

    SciTech Connect

    White, B; Lin, L; Freedmen, G; Both, S; Vennarini, S

    2014-06-15

    Purpose: To assess the feasibility of routine treatment planning 4DCT and deep inspiration breath-hold (DIBH) to accurately contour the left anterior descending artery (LAD), a primary indicator of cardiac toxicity, for radiotherapy treatment planning of breast cancer. Methods: Ten subjects were imaged with a cardiac-gated MRI protocol to determine the displacement of a ROI that included the LAD. The subjects performed a series of breath-hold maneuvers to obtain short-axis and radial views, which were resampled to create a 3D-volume. Tissue motion was determined using a multi-resolution 3D optical flow deformable image registration algorithm. The ROI motion was then used as a spatial boundary to characterize the blurring motion of the LAD in ten patients during clinical 4DCT and DIBH protocols. A radiologist contoured the LAD. Coronary motion-induced blurring artifacts were quantified by applying an unsharp filter to accentuate the LAD despite motion-blurring. The 4DCT maximum inhalation and exhalation respiratory phases were co-registered to determine the LAD displacement during tidal respiration, as visualized in 4DCT. Results: The average 90{sup th} percentile heart motion for the ROI was 0.7±0.1mm(LR), 1.3±0.6mm(SI), 0.6±0.2mm(AP) in the cardiac-gated MRI cohort. The average relative increase in the number of voxels comprising the LAD contour was 69.4±4.5% for the DIBH. During tidal respiration, the average relative increase in the LAD contour was 69.3±5.9% and 67.9±4.6% for inhalation and exhalation respiratory phases respectively. The average 90{sup th} percentile LAD motion was 4.8±1.1mm(LR), 0.9±0.4mm(SI), 1.9±0.6mm(AP) for the 4DCT cohort, in the absence of cardiac-gating. Conclusion: Uncompensated coronary motion was the dominant form of motion blurring present in the CT images due to the high frequency of the cardiac cycle relative to the respiratory cycle. The 4D and DIBH CT contour delineation of the LAD was consistently overestimated without

  20. Aneurysm of the proximal thoracic aorta simulating neoplasm: the role of CT and angiography

    SciTech Connect

    Smith, T.R.; Khoury, P.T.

    1985-05-01

    Ascending aortic and proximal transverse arch aneurysms may sometimes project to the left of midline and be difficult to distinguish from neoplasm. The authors have recently encountered three such cases that presented as possible neoplastic soft-tissue masses overlying the left upper lobe. They did not enhance on intravenous-contrast-enhanced CT scans, and in two cases the diagnosis of aneurysm was not confirmed until angiography was performed.

  1. Automatic thoracic anatomy segmentation on CT images using hierarchical fuzzy models and registration

    NASA Astrophysics Data System (ADS)

    Sun, Kaioqiong; Udupa, Jayaram K.; Odhner, Dewey; Tong, Yubing; Torigian, Drew A.

    2014-03-01

    This paper proposes a thoracic anatomy segmentation method based on hierarchical recognition and delineation guided by a built fuzzy model. Labeled binary samples for each organ are registered and aligned into a 3D fuzzy set representing the fuzzy shape model for the organ. The gray intensity distributions of the corresponding regions of the organ in the original image are recorded in the model. The hierarchical relation and mean location relation between different organs are also captured in the model. Following the hierarchical structure and location relation, the fuzzy shape model of different organs is registered to the given target image to achieve object recognition. A fuzzy connected delineation method is then used to obtain the final segmentation result of organs with seed points provided by recognition. The hierarchical structure and location relation integrated in the model provide the initial parameters for registration and make the recognition efficient and robust. The 3D fuzzy model combined with hierarchical affine registration ensures that accurate recognition can be obtained for both non-sparse and sparse organs. The results on real images are presented and shown to be better than a recently reported fuzzy model-based anatomy recognition strategy.

  2. SU-D-207-01: Markerless Respiratory Motion Tracking with Contrast Enhanced Thoracic Cone Beam CT Projections

    SciTech Connect

    Chao, M; Yuan, Y; Rosenzweig, K; Lo, Y; Brousmiche, S

    2015-06-15

    Purpose: To develop a novel technique to enhance the image contrast of clinical cone beam CT projections and extract respiratory signals based on anatomical motion using the modified Amsterdam Shroud (AS) method to benefit image guided radiation therapy. Methods: Thoracic cone beam CT projections acquired prior to treatment were preprocessed to increase their contrast for better respiratory signal extraction. Air intensity on raw images was firstly estimated and then applied to correct the projections to generate new attenuation images that were subsequently improved with deeper anatomy feature enhancement through taking logarithm operation, derivative along superior-inferior direction, respectively. All pixels on individual post-processed two dimensional images were horizontally summed to one column and all projections were combined side by side to create an AS image from which patient’s respiratory signal was extracted. The impact of gantry rotation on the breathing signal rendering was also investigated. Ten projection image sets from five lung cancer patients acquired with the Varian Onboard Imager on 21iX Clinac (Varian Medical Systems, Palo Alto, CA) were employed to assess the proposed technique. Results: Application of the air correction on raw projections showed that more than an order of magnitude of contrast enhancement was achievable. The typical contrast on the raw projections is around 0.02 while that on attenuation images could greater than 0.5. Clear and stable breathing signal can be reliably extracted from the new images while the uncorrected projection sets failed to yield clear signals most of the time. Conclusion: Anatomy feature plays a key role in yielding breathing signal from the projection images using the AS technique. The air correction process facilitated the contrast enhancement significantly and attenuation images thus obtained provides a practical solution to obtaining markerless breathing motion tracking.

  3. Every second counts: signs of a failing heart on thoracic CT in the ED.

    PubMed

    Maldow, David J; Chaturvedi, Abhishek; Kaproth-Joslin, Katherine

    2017-02-27

    Impending cardiac failure is often difficult to recognize and requires a multidisciplinary approach. Upon arrival in the emergency department, patients are promptly screened for potentially life-threatening conditions through a history and physical examination. In many cases, the diagnosis is not clear until confirmatory laboratory or imaging tests are performed. Unfortunately, patients can rapidly decompensate as this diagnostic information is being obtained. Emergent CT plays a key role in identifying conditions that may result in cardiovascular collapse, including severe congestive heart failure, myocardial infarction, cardiac tamponade, and impending cardiac failure. Characteristic imaging findings can prompt the physician to take immediate action and prepare for resuscitation.

  4. Multi-detector thoracic CT findings in cerebro-costo-mandibular syndrome: rib gaps and failure of costo-vertebral separation.

    PubMed

    Watson, Tom Anthony; Arthurs, Owen John; Muthialu, Nagarajan; Calder, Alistair Duncan

    2014-02-01

    Cerebro-costo-mandibular syndrome (CCMS) describes a triad of mandibular hypoplasia, brain dysfunction and posterior rib defects ("rib gaps"). We present the CT imaging for a 2-year-old girl with CCMS that highlights the rib gap defects and shows absent transverse processes with abnormal fusion of the ribs directly to the vertebral bodies. We argue that this is likely to relate to abnormal lateral sclerotome development in embryology, with the failure of normal costo-vertebral junctions compounding impaired thoracic function. The case also highlights the use of CT for specific indications in skeletal dysplasia.

  5. Mediastinal lymph node detection on thoracic CT scans using spatial prior from multi-atlas label fusion

    NASA Astrophysics Data System (ADS)

    Liu, Jiamin; Zhao, Jocelyn; Hoffman, Joanne; Yao, Jianhua; Zhang, Weidong; Turkbey, Evrim B.; Wang, Shijun; Kim, Christine; Summers, Ronald M.

    2014-03-01

    Lymph nodes play an important role in clinical practice but detection is challenging due to low contrast surrounding structures and variable size and shape. We propose a fully automatic method for mediastinal lymph node detection on thoracic CT scans. First, lungs are automatically segmented to locate the mediastinum region. Shape features by Hessian analysis, local scale, and circular transformation are computed at each voxel. Spatial prior distribution is determined based on the identification of multiple anatomical structures (esophagus, aortic arch, heart, etc.) by using multi-atlas label fusion. Shape features and spatial prior are then integrated for lymph node detection. The detected candidates are segmented by curve evolution. Characteristic features are calculated on the segmented lymph nodes and support vector machine is utilized for classification and false positive reduction. We applied our method to 20 patients with 62 enlarged mediastinal lymph nodes. The system achieved a significant improvement with 80% sensitivity at 8 false positives per patient with spatial prior compared to 45% sensitivity at 8 false positives per patient without a spatial prior.

  6. A Novel Fast Helical 4D-CT Acquisition Technique to Generate Low-Noise Sorting Artifact–Free Images at User-Selected Breathing Phases

    SciTech Connect

    Thomas, David; Lamb, James; White, Benjamin; Jani, Shyam; Gaudio, Sergio; Lee, Percy; Ruan, Dan; McNitt-Gray, Michael; Low, Daniel

    2014-05-01

    Purpose: To develop a novel 4-dimensional computed tomography (4D-CT) technique that exploits standard fast helical acquisition, a simultaneous breathing surrogate measurement, deformable image registration, and a breathing motion model to remove sorting artifacts. Methods and Materials: Ten patients were imaged under free-breathing conditions 25 successive times in alternating directions with a 64-slice CT scanner using a low-dose fast helical protocol. An abdominal bellows was used as a breathing surrogate. Deformable registration was used to register the first image (defined as the reference image) to the subsequent 24 segmented images. Voxel-specific motion model parameters were determined using a breathing motion model. The tissue locations predicted by the motion model in the 25 images were compared against the deformably registered tissue locations, allowing a model prediction error to be evaluated. A low-noise image was created by averaging the 25 images deformed to the first image geometry, reducing statistical image noise by a factor of 5. The motion model was used to deform the low-noise reference image to any user-selected breathing phase. A voxel-specific correction was applied to correct the Hounsfield units for lung parenchyma density as a function of lung air filling. Results: Images produced using the model at user-selected breathing phases did not suffer from sorting artifacts common to conventional 4D-CT protocols. The mean prediction error across all patients between the breathing motion model predictions and the measured lung tissue positions was determined to be 1.19 ± 0.37 mm. Conclusions: The proposed technique can be used as a clinical 4D-CT technique. It is robust in the presence of irregular breathing and allows the entire imaging dose to contribute to the resulting image quality, providing sorting artifact–free images at a patient dose similar to or less than current 4D-CT techniques.

  7. Automated integer programming based separation of arteries and veins from thoracic CT images.

    PubMed

    Payer, Christian; Pienn, Michael; Bálint, Zoltán; Shekhovtsov, Alexander; Talakic, Emina; Nagy, Eszter; Olschewski, Andrea; Olschewski, Horst; Urschler, Martin

    2016-12-01

    Automated computer-aided analysis of lung vessels has shown to yield promising results for non-invasive diagnosis of lung diseases. To detect vascular changes which affect pulmonary arteries and veins differently, both compartments need to be identified. We present a novel, fully automatic method that separates arteries and veins in thoracic computed tomography images, by combining local as well as global properties of pulmonary vessels. We split the problem into two parts: the extraction of multiple distinct vessel subtrees, and their subsequent labeling into arteries and veins. Subtree extraction is performed with an integer program (IP), based on local vessel geometry. As naively solving this IP is time-consuming, we show how to drastically reduce computational effort by reformulating it as a Markov Random Field. Afterwards, each subtree is labeled as either arterial or venous by a second IP, using two anatomical properties of pulmonary vessels: the uniform distribution of arteries and veins, and the parallel configuration and close proximity of arteries and bronchi. We evaluate algorithm performance by comparing the results with 25 voxel-based manual reference segmentations. On this dataset, we show good performance of the subtree extraction, consisting of very few non-vascular structures (median value: 0.9%) and merged subtrees (median value: 0.6%). The resulting separation of arteries and veins achieves a median voxel-based overlap of 96.3% with the manual reference segmentations, outperforming a state-of-the-art interactive method. In conclusion, our novel approach provides an opportunity to become an integral part of computer aided pulmonary diagnosis, where artery/vein separation is important.

  8. Tracking 'differential organ motion' with a 'breathing' multileaf collimator: magnitude of problem assessed using 4D CT data and a motion-compensation strategy.

    PubMed

    McClelland, J R; Webb, S; McQuaid, D; Binnie, D M; Hawkes, D J

    2007-08-21

    Intrafraction tumour (e.g. lung) motion due to breathing can, in principle, be compensated for by applying identical breathing motions to the leaves of a multileaf collimator (MLC) as intensity-modulated radiation therapy is delivered by the dynamic MLC (DMLC) technique. A difficulty arising, however, is that irradiated voxels, which are in line with a bixel at one breathing phase (at which the treatment plan has been made), may move such that they cease to be in line with that breathing bixel at another phase. This is the phenomenon of differential voxel motion and existing tracking solutions have ignored this very real problem. There is absolutely no tracking solution to the problem of compensating for differential voxel motion. However, there is a strategy that can be applied in which the leaf breathing is determined to minimize the geometrical mismatch in a least-squares sense in irradiating differentially-moving voxels. A 1D formulation in very restricted circumstances is already in the literature and has been applied to some model breathing situations which can be studied analytically. These are, however, highly artificial. This paper presents the general 2D formulation of the problem including allowing different importance factors to be applied to planning target volume and organ at risk (or most generally) each voxel. The strategy also extends the literature strategy to the situation where the number of voxels connecting to a bixel is a variable. Additionally the phenomenon of 'cross-leaf-track/channel' voxel motion is formally addressed. The general equations are presented and analytic results are given for some 1D, artificially contrived, motions based on the Lujan equations of breathing motion. Further to this, 3D clinical voxel motion data have been extracted from 4D CT measurements to both assess the magnitude of the problem of 2D motion perpendicular to the beam-delivery axis in clinical practice and also to find the 2D optimum breathing-leaf strategy

  9. TH-E-17A-09: High Quality and Artifact-Free 4D Cone Beam CT and Its Application in Adaptive Treatment Planning

    SciTech Connect

    Niu, K; Li, K; Smilowitz, J; Chen, G

    2014-06-15

    Purpose: To develop a high quality 4D cone beam CT (4DCBCT) method that is immune to patient/couch truncations and to investigate its application in adaptive replanning of lung XRT. Methods: In this study, IRB-approved human subject CBCT data was acquired using a Varian on-board imager with 1 minute rotation time. The acquired projection data was retrospectively sorted into 20 respiratory phase bins, from which 4DCBCT images with high SNR and high temporal resolution were generated using Prior Image Constrained Compressed Sensing (PICCS). Couch and patient truncations generate strong data inconsistency in the projection data and artifacts in the 4DCBCT image. They were addressed using an adaptive PICCS method. The artifact-free PICCS-4DCBCT images were used to generate adaptive treatment plans for the same patient at the 10th (day 21) and 30th (day 47) fractions. Dosimetric impacts with and without PICCS- 4DCBCT were evaluated by isodose distributions, DVHs, and other dosimetric factors. Results: The adaptive PICCS-4DCBCT method improves image quality by removing residue truncation artifacts; measured universal image quality increased 37%. The isodose lines and DVHs with PICCS-4DCBCT-based adaptive replanning were significantly more conformal to PTV than without replanning due to changes in patient anatomy caused by progress of the treatment. The mean dose to PTV at the 10th fraction was 63.1Gy with replanning and 64.2Gy without replanning, where the prescribed dose was 60Gy, in 2Gy × 30 fractions. The mean dose to PTV at the 30th fraction was 61.6Gy with replanning and 64.9Gy without replanning. Lung V20 was 37.1%, 41.9% and 43.3% for original plan, 10th fraction plan and 30th fraction plan; with re-planning, Lung V20 was 37.1%, 32%, 27.8%. Conclusion: 4DCBCT imaging using adaptive PICCS is able to generate high quality, artifact-free images that potentially can be used to create replanning for improving radiotherapy of the lung. K Niu, K Li, J Smilowitz: Nothing

  10. Tracking 'differential organ motion' with a 'breathing' multileaf collimator: magnitude of problem assessed using 4D CT data and a motion-compensation strategy

    NASA Astrophysics Data System (ADS)

    McClelland, J. R.; Webb, S.; McQuaid, D.; Binnie, D. M.; Hawkes, D. J.

    2007-08-01

    Intrafraction tumour (e.g. lung) motion due to breathing can, in principle, be compensated for by applying identical breathing motions to the leaves of a multileaf collimator (MLC) as intensity-modulated radiation therapy is delivered by the dynamic MLC (DMLC) technique. A difficulty arising, however, is that irradiated voxels, which are in line with a bixel at one breathing phase (at which the treatment plan has been made), may move such that they cease to be in line with that breathing bixel at another phase. This is the phenomenon of differential voxel motion and existing tracking solutions have ignored this very real problem. There is absolutely no tracking solution to the problem of compensating for differential voxel motion. However, there is a strategy that can be applied in which the leaf breathing is determined to minimize the geometrical mismatch in a least-squares sense in irradiating differentially-moving voxels. A 1D formulation in very restricted circumstances is already in the literature and has been applied to some model breathing situations which can be studied analytically. These are, however, highly artificial. This paper presents the general 2D formulation of the problem including allowing different importance factors to be applied to planning target volume and organ at risk (or most generally) each voxel. The strategy also extends the literature strategy to the situation where the number of voxels connecting to a bixel is a variable. Additionally the phenomenon of 'cross-leaf-track/channel' voxel motion is formally addressed. The general equations are presented and analytic results are given for some 1D, artificially contrived, motions based on the Lujan equations of breathing motion. Further to this, 3D clinical voxel motion data have been extracted from 4D CT measurements to both assess the magnitude of the problem of 2D motion perpendicular to the beam-delivery axis in clinical practice and also to find the 2D optimum breathing-leaf strategy

  11. Thoracic dual energy CT: acquisition protocols, current applications and future developments.

    PubMed

    Ohana, M; Jeung, M Y; Labani, A; El Ghannudi, S; Roy, C

    2014-11-01

    Thanks to a simultaneous acquisition at high and low kilovoltage, dual energy computed tomography (DECT) can achieve material-based decomposition (iodine, water, calcium, etc.) and reconstruct images at different energy levels (40 to 140keV). Post-processing uses this potential to maximise iodine detection, which elicits demonstrated added value for chest imaging in acute and chronic embolic diseases (increases the quality of the examination and identifies perfusion defects), follow-up of aortic endografts and detection of contrast uptake in oncology. In CT angiography, these unique features are taken advantage of to reduce the iodine load by more than half. This review article aims to set out the physical basis for the technology, the acquisition and post-processing protocols used, its proven advantages in chest pathologies, and to present future developments.

  12. Quality Assurance of 4D-CT Scan Techniques in Multicenter Phase III Trial of Surgery Versus Stereotactic Radiotherapy (Radiosurgery or Surgery for Operable Early Stage (Stage 1A) Non-Small-Cell Lung Cancer [ROSEL] Study)

    SciTech Connect

    Hurkmans, Coen W.; Lieshout, Maarten van; Schuring, Danny; Heumen, Marielle J.T. van; Cuijpers, Johan P.; Lagerwaard, Frank J.; Widder, Joachim; Heide, Uulke A. van der; Senan, Suresh

    2011-07-01

    Purpose: To determine the accuracy of four-dimensional computed tomography (4D-CT) scanning techniques in institutions participating in a Phase III trial of surgery vs. stereotactic radiotherapy (SBRT) for lung cancer. Methods and Materials: All 9 centers performed a 4D-CT scan of a motion phantom (Quasar, Modus Medical Devices) in accordance with their in-house imaging protocol for SBRT. A cylindrical cedar wood insert with plastic spheres of 15 mm (o15) and 30 mm (o30) diameter was moved in a cosine-based pattern, with an extended period in the exhale position to mimic the actual breathing motion. A range of motion of R = 15 and R = 25 mm and breathing period of T = 3 and T = 6 s were used. Positional and volumetric imaging accuracy was analyzed using Pinnacle version 8.1x at various breathing phases, including the mid-ventilation phase and maximal intensity projections of the spheres. Results: Imaging using eight CT scanners (Philips, Siemens, GE) and one positron emission tomography-CT scanner (Institution 3, Siemens) was investigated. The imaging protocols varied widely among the institutions. No strong correlation was found between the specific scan protocol parameters and the observed results. Deviations in the maximal intensity projection volumes averaged 1.9% (starting phase of the breathing cycle [o]15, R = 15), 12.3% (o15, R = 25), and -0.9% (o30, R = 15). The end-expiration volume deviations (13.4%, o15 and 2.5%, o30), were, on average, smaller than the end-inspiration deviations (20.7%, o15 and 4.5%, o30), which, in turn, were smaller than the mid-ventilation deviations (32.6%, o15 and 8.0%, o30). A slightly larger variation in the mid-ventilation origin position was observed (mean, -0.2 mm; range, -3.6-4.2) than in the maximal intensity projection origin position (mean, -0.1 mm; range, -2.5-2.5). The range of motion was generally underestimated (mean, -1.5 mm; range, -5.5-1). Conclusions: Notable differences were seen in the 4D-CT imaging protocols

  13. SU-E-J-123: Assessing Segmentation Accuracy of Internal Volumes and Sub-Volumes in 4D PET/CT of Lung Tumors Using a Novel 3D Printed Phantom

    SciTech Connect

    Soultan, D; Murphy, J; James, C; Hoh, C; Moiseenko, V; Cervino, L; Gill, B

    2015-06-15

    Purpose: To assess the accuracy of internal target volume (ITV) segmentation of lung tumors for treatment planning of simultaneous integrated boost (SIB) radiotherapy as seen in 4D PET/CT images, using a novel 3D-printed phantom. Methods: The insert mimics high PET tracer uptake in the core and 50% uptake in the periphery, by using a porous design at the periphery. A lung phantom with the insert was placed on a programmable moving platform. Seven breathing waveforms of ideal and patient-specific respiratory motion patterns were fed to the platform, and 4D PET/CT scans were acquired of each of them. CT images were binned into 10 phases, and PET images were binned into 5 phases following the clinical protocol. Two scenarios were investigated for segmentation: a gate 30–70 window, and no gating. The radiation oncologist contoured the outer ITV of the porous insert with on CT images, while the internal void volume with 100% uptake was contoured on PET images for being indistinguishable from the outer volume in CT images. Segmented ITVs were compared to the expected volumes based on known target size and motion. Results: 3 ideal breathing patterns, 2 regular-breathing patient waveforms, and 2 irregular-breathing patient waveforms were used for this study. 18F-FDG was used as the PET tracer. The segmented ITVs from CT closely matched the expected motion for both no gating and gate 30–70 window, with disagreement of contoured ITV with respect to the expected volume not exceeding 13%. PET contours were seen to overestimate volumes in all the cases, up to more than 40%. Conclusion: 4DPET images of a novel 3D printed phantom designed to mimic different uptake values were obtained. 4DPET contours overestimated ITV volumes in all cases, while 4DCT contours matched expected ITV volume values. Investigation of the cause and effects of the discrepancies is undergoing.

  14. Optimized PET imaging for 4D treatment planning in radiotherapy: the virtual 4D PET strategy.

    PubMed

    Gianoli, Chiara; Riboldi, Marco; Fontana, Giulia; Giri, Maria G; Grigolato, Daniela; Ferdeghini, Marco; Cavedon, Carlo; Baroni, Guido

    2015-02-01

    The purpose of the study is to evaluate the performance of a novel strategy, referred to as "virtual 4D PET", aiming at the optimization of hybrid 4D CT-PET scan for radiotherapy treatment planning. The virtual 4D PET strategy applies 4D CT motion modeling to avoid time-resolved PET image acquisition. This leads to a reduction of radioactive tracer administered to the patient and to a total acquisition time comparable to free-breathing PET studies. The proposed method exploits a motion model derived from 4D CT, which is applied to the free-breathing PET to recover respiratory motion and motion blur. The free-breathing PET is warped according to the motion model, in order to generate the virtual 4D PET. The virtual 4D PET strategy was tested on images obtained from a 4D computational anthropomorphic phantom. The performance was compared to conventional motion compensated 4D PET. Tests were also carried out on clinical 4D CT-PET scans coming from seven lung and liver cancer patients. The virtual 4D PET strategy was able to recover lesion motion, with comparable performance with respect to the motion compensated 4D PET. The compensation of the activity blurring due to motion was successfully achieved in terms of spill out removal. Specific limitations were highlighted in terms of partial volume compensation. Results on clinical 4D CT-PET scans confirmed the efficacy in 4D PET count statistics optimization, as equal to the free-breathing PET, and recovery of lesion motion. Compared to conventional motion compensation strategies that explicitly require 4D PET imaging, the virtual 4D PET strategy reduces clinical workload and computational costs, resulting in significant advantages for radiotherapy treatment planning.

  15. A comparative study of target volumes based on 18F-FDG PET-CT and ten phases of 4DCT for primary thoracic squamous esophageal cancer

    PubMed Central

    Guo, Yanluan; Li, Jianbin; Zhang, Peng; Zhang, Yingjie

    2017-01-01

    Purpose To investigate the correlations in target volumes based on 18F-FDG PET/CT and four-dimensional CT (4DCT) to detect the feasibility of implementing PET in determining gross target volumes (GTV) for tumor motion for primary thoracic esophageal cancer (EC). Methods Thirty-three patients with EC sequentially underwent contrast-enhanced 3DCT, 4DCT, and 18F-FDG PET-CT thoracic simulation. The internal gross target volume (IGTV)10 was obtained by combining the GTV from ten phases of 4DCT. The GTVs based on PET/CT images were defined by setting of different standardized uptake value thresholds and visual contouring. The difference in volume ratio, conformity index (CI), and degree of inclusion (DI) between IGTV10 and GTVPET was compared. Results The images from 20 patients were suitable for further analysis. The optimal volume ratio of 0.95±0.32, 1.06±0.50, 1.07±0.49 was at standardized uptake value (SUV)2.5, SUV20%, or manual contouring. The mean CIs were from 0.33 to 0.54. The best CIs were at SUV2.0 (0.51±0.11), SUV2.5 (0.53±0.13), SUV20% (0.53±0.12), and manual contouring (0.54±0.14). The mean DIs of GTVPET in IGTV10 were from 0.60 to 0.90, and the mean DIs of IGTV10 in GTVPET ranged from 0.35 to 0.78. A negative correlation was found between the mean CI and different SUV (P=0.000). Conclusion None of the PET-based contours had both close spatial and volumetric approximation to the 4DCT IGTV10. Further evaluation and optimization of PET as a tool for target identification are required. PMID:28123302

  16. Accuracy and Utility of Deformable Image Registration in {sup 68}Ga 4D PET/CT Assessment of Pulmonary Perfusion Changes During and After Lung Radiation Therapy

    SciTech Connect

    Hardcastle, Nicholas; Hofman, Michael S.; Hicks, Rodney J.; Callahan, Jason; Kron, Tomas; MacManus, Michael P.; Ball, David L.; Jackson, Price; Siva, Shankar

    2015-09-01

    Purpose: Measuring changes in lung perfusion resulting from radiation therapy dose requires registration of the functional imaging to the radiation therapy treatment planning scan. This study investigates registration accuracy and utility for positron emission tomography (PET)/computed tomography (CT) perfusion imaging in radiation therapy for non–small cell lung cancer. Methods: {sup 68}Ga 4-dimensional PET/CT ventilation-perfusion imaging was performed before, during, and after radiation therapy for 5 patients. Rigid registration and deformable image registration (DIR) using B-splines and Demons algorithms was performed with the CT data to obtain a deformation map between the functional images and planning CT. Contour propagation accuracy and correspondence of anatomic features were used to assess registration accuracy. Wilcoxon signed-rank test was used to determine statistical significance. Changes in lung perfusion resulting from radiation therapy dose were calculated for each registration method for each patient and averaged over all patients. Results: With B-splines/Demons DIR, median distance to agreement between lung contours reduced modestly by 0.9/1.1 mm, 1.3/1.6 mm, and 1.3/1.6 mm for pretreatment, midtreatment, and posttreatment (P<.01 for all), and median Dice score between lung contours improved by 0.04/0.04, 0.05/0.05, and 0.05/0.05 for pretreatment, midtreatment, and posttreatment (P<.001 for all). Distance between anatomic features reduced with DIR by median 2.5 mm and 2.8 for pretreatment and midtreatment time points, respectively (P=.001) and 1.4 mm for posttreatment (P>.2). Poorer posttreatment results were likely caused by posttreatment pneumonitis and tumor regression. Up to 80% standardized uptake value loss in perfusion scans was observed. There was limited change in the loss in lung perfusion between registration methods; however, Demons resulted in larger interpatient variation compared with rigid and B-splines registration

  17. Evaluation of various deformable image registration algorithms for thoracic images.

    PubMed

    Kadoya, Noriyuki; Fujita, Yukio; Katsuta, Yoshiyuki; Dobashi, Suguru; Takeda, Ken; Kishi, Kazuma; Kubozono, Masaki; Umezawa, Rei; Sugawara, Toshiyuki; Matsushita, Haruo; Jingu, Keiichi

    2014-01-01

    We evaluated the accuracy of one commercially available and three publicly available deformable image registration (DIR) algorithms for thoracic four-dimensional (4D) computed tomography (CT) images. Five patients with esophagus cancer were studied. Datasets of the five patients were provided by DIR-lab (dir-lab.com) and consisted of thoracic 4D CT images and a coordinate list of anatomical landmarks that had been manually identified. Expert landmark correspondence was used for evaluating DIR spatial accuracy. First, the manually measured displacement vector field (mDVF) was obtained from the coordinate list of anatomical landmarks. Then the automatically calculated displacement vector field (aDVF) was calculated by using the following four DIR algorithms: B-spine implemented in Velocity AI (Velocity Medical, Atlanta, GA, USA), free-form deformation (FFD), Horn-Schunk optical flow (OF) and Demons in DIRART of MATLAB software. Registration error is defined as the difference between mDVF and aDVF. The mean 3D registration errors were 2.7 ± 0.8 mm for B-spline, 3.6 ± 1.0 mm for FFD, 2.4 ± 0.9 mm for OF and 2.4 ± 1.2 mm for Demons. The results showed that reasonable accuracy was achieved in B-spline, OF and Demons, and that these algorithms have the potential to be used for 4D dose calculation, automatic image segmentation and 4D CT ventilation imaging in patients with thoracic cancer. However, for all algorithms, the accuracy might be improved by using the optimized parameter setting. Furthermore, for B-spline in Velocity AI, the 3D registration error was small with displacements of less than ∼10 mm, indicating that this software may be useful in this range of displacements.

  18. A computerized approach for estimating pulmonary nodule growth rates in three-dimensional thoracic CT images based on CT density histogram

    NASA Astrophysics Data System (ADS)

    Kawata, Yoshiki; Niki, Noboru; Ohmatsu, Hironobu; Kusumoto, Masahiko; Kakinuma, Ryutaro; Mori, Kiyoshi; Yamada, Kozo; Nishiyama, Hiroyuki; Eguchi, Kenji; Kaneko, Masahiro; Moriyama, Noriyuki

    2005-04-01

    In research and development of computer-aided differential diagnosis, there is now a widespread interest in the use of nodule doubling time for measuring the volumetric changes of pulmonary nodule. To assess nodule status requires not only the measurement of volume changes but also one of nodule density variations. This paper proposes a computerized approach to measure nodule density variation inside small pulmonary nodule using CT images. The approach consists of five steps: (1) nodule segmentation, (2) computation of CT density histogram, (3) nodule classification based on CT density histogram and size, (4) computation of doubling time based on CT density histogram, and (5) classification between benign and malignant. Our approach was applied to follow-up scans of lung nodules. The preliminary experimental result demonstrated that our approach has a highly potential usefulness to assess the nodule evolution using high-resolution CT images.

  19. Evaluation of the cone beam CT for internal target volume localization in lung stereotactic radiotherapy in comparison with 4D MIP images

    SciTech Connect

    Wang, Lu; Chen, Xiaoming; Lin, Mu-Han; Lin, Teh; Fan, Jiajin; Jin, Lihui; Ma, Charlie M.; Xue, Jun

    2013-11-15

    Purpose: To investigate whether the three-dimensional cone-beam CT (CBCT) is clinically equivalent to the four-dimensional computed tomography (4DCT) maximum intensity projection (MIP) reconstructed images for internal target volume (ITV) localization in image-guided lung stereotactic radiotherapy.Methods: A ball-shaped polystyrene phantom with built-in cube, sphere, and cone of known volumes was attached to a motor-driven platform, which simulates a sinusoidal movement with changeable motion amplitude and frequency. Target motion was simulated in the patient in a superior-inferior (S-I) direction with three motion periods and 2 cm peak-to-peak amplitudes. The Varian onboard Exact-Arms kV CBCT system and the GE LightSpeed four-slice CT integrated with the respiratory-position-management 4DCT scanner were used to scan the moving phantom. MIP images were generated from the 4DCT images. The clinical equivalence of the two sets of images was evaluated by comparing the extreme locations of the moving objects along the motion direction, the centroid position of the ITV, and the ITV volumes that were contoured automatically by Velocity or calculated with an imaging gradient method. The authors compared the ITV volumes determined by the above methods with those theoretically predicted by taking into account the physical object dimensions and the motion amplitudes. The extreme locations were determined by the gradient method along the S-I axis through the center of the object. The centroid positions were determined by autocenter functions. The effect of motion period on the volume sizes was also studied.Results: It was found that the extreme locations of the objects determined from the two image modalities agreed with each other satisfactorily. They were not affected by the motion period. The average difference between the two modalities in the extreme locations was 0.68% for the cube, 1.35% for the sphere, and 0.5% for the cone, respectively. The maximum difference in the

  20. Radiation dose reduction to the breast in thoracic CT: Comparison of bismuth shielding, organ-based tube current modulation, and use of a globally decreased tube current

    SciTech Connect

    Wang Jia; Duan Xinhui; Christner, Jodie A.; Leng Shuai; Yu Lifeng; McCollough, Cynthia H.

    2011-11-15

    Purpose: The purpose of this work was to evaluate dose performance and image quality in thoracic CT using three techniques to reduce dose to the breast: bismuth shielding, organ-based tube current modulation (TCM) and global tube current reduction. Methods: Semi-anthropomorphic thorax phantoms of four different sizes (15, 30, 35, and 40 cm lateral width) were used for dose measurement and image quality assessment. Four scans were performed on each phantom using 100 or 120 kV with a clinical CT scanner: (1) reference scan; (2) scan with bismuth breast shield of an appropriate thickness; (3) scan with organ-based TCM; and (4) scan with a global reduction in tube current chosen to match the dose reduction from bismuth shielding. Dose to the breast was measured with an ion chamber on the surface of the phantom. Image quality was evaluated by measuring the mean and standard deviation of CT numbers within the lung and heart regions. Results: Compared to the reference scan, dose to the breast region was decreased by about 21% for the 15-cm phantom with a pediatric (2-ply) shield and by about 37% for the 30, 35, and 40-cm phantoms with adult (4-ply) shields. Organ-based TCM decreased the dose by 12% for the 15-cm phantom, and 34-39% for the 30, 35, and 40-cm phantoms. Global lowering of the tube current reduced breast dose by 23% for the 15-cm phantom and 39% for the 30, 35, and 40-cm phantoms. In phantoms of all four sizes, image noise was increased in both the lung and heart regions with bismuth shielding. No significant increase in noise was observed with organ-based TCM. Decreasing tube current globally led to similar noise increases as bismuth shielding. Streak and beam hardening artifacts, and a resulting artifactual increase in CT numbers, were observed for scans with bismuth shields, but not for organ-based TCM or global tube current reduction. Conclusions: Organ-based TCM produces dose reduction to the breast similar to that achieved with bismuth shielding for

  1. PET-Based Thoracic Radiation Oncology.

    PubMed

    Simone, Charles B; Houshmand, Sina; Kalbasi, Anusha; Salavati, Ali; Alavi, Abass

    2016-07-01

    Fluorodeoxyglucose-PET is increasingly being integrated into multiple aspects of oncology. PET/computed tomography (PET/CT) has become especially important in radiation oncology. With the increasing use of advanced techniques like intensity-modulated radiation therapy and proton therapy, PET/CT scans have played critical roles in the target delineation of tumors for radiation oncologists delivering conformal treatment techniques. Use of PET/CT is well established in lung cancer and several other thoracic malignancies. This article details the current uses of PET/CT in thoracic radiation oncology with a focus on lung cancer and describes expected future roles of PET/CT for thoracic tumors.

  2. Computer-assisted detection (CAD) of pulmonary nodules on thoracic CT scans using image processing and classification techniques

    NASA Astrophysics Data System (ADS)

    Dehmeshki, Jamshid; Valdivieso-Casique, Manlio; Siddique, Musib; Dehkordi, Mandana E.; Costello, John; Roddie, Mary

    2004-05-01

    Computer assisted methods for the detection of pulmonary nodules have become more important as the resolution of CT scanners has increased and as more accurate and reproducible detections are needed. In this paper we describe the results of a CAD system for the detection of lung nodules and compare them against the interpretations of three independent radiologists.

  3. 4-D photoacoustic tomography.

    PubMed

    Xiang, Liangzhong; Wang, Bo; Ji, Lijun; Jiang, Huabei

    2013-01-01

    Photoacoustic tomography (PAT) offers three-dimensional (3D) structural and functional imaging of living biological tissue with label-free, optical absorption contrast. These attributes lend PAT imaging to a wide variety of applications in clinical medicine and preclinical research. Despite advances in live animal imaging with PAT, there is still a need for 3D imaging at centimeter depths in real-time. We report the development of four dimensional (4D) PAT, which integrates time resolutions with 3D spatial resolution, obtained using spherical arrays of ultrasonic detectors. The 4D PAT technique generates motion pictures of imaged tissue, enabling real time tracking of dynamic physiological and pathological processes at hundred micrometer-millisecond resolutions. The 4D PAT technique is used here to image needle-based drug delivery and pharmacokinetics. We also use this technique to monitor 1) fast hemodynamic changes during inter-ictal epileptic seizures and 2) temperature variations during tumor thermal therapy.

  4. 4-D Photoacoustic Tomography

    NASA Astrophysics Data System (ADS)

    Xiang, Liangzhong; Wang, Bo; Ji, Lijun; Jiang, Huabei

    2013-01-01

    Photoacoustic tomography (PAT) offers three-dimensional (3D) structural and functional imaging of living biological tissue with label-free, optical absorption contrast. These attributes lend PAT imaging to a wide variety of applications in clinical medicine and preclinical research. Despite advances in live animal imaging with PAT, there is still a need for 3D imaging at centimeter depths in real-time. We report the development of four dimensional (4D) PAT, which integrates time resolutions with 3D spatial resolution, obtained using spherical arrays of ultrasonic detectors. The 4D PAT technique generates motion pictures of imaged tissue, enabling real time tracking of dynamic physiological and pathological processes at hundred micrometer-millisecond resolutions. The 4D PAT technique is used here to image needle-based drug delivery and pharmacokinetics. We also use this technique to monitor 1) fast hemodynamic changes during inter-ictal epileptic seizures and 2) temperature variations during tumor thermal therapy.

  5. Fast and Adaptive Detection of Pulmonary Nodules in Thoracic CT Images Using a Hierarchical Vector Quantization Scheme

    PubMed Central

    Han, Hao; Li, Lihong; Han, Fangfang; Song, Bowen; Moore, William; Liang, Zhengrong

    2014-01-01

    Computer-aided detection (CADe) of pulmonary nodules is critical to assisting radiologists in early identification of lung cancer from computed tomography (CT) scans. This paper proposes a novel CADe system based on a hierarchical vector quantization (VQ) scheme. Compared with the commonly-used simple thresholding approach, high-level VQ yields a more accurate segmentation of the lungs from the chest volume. In identifying initial nodule candidates (INCs) within the lungs, low-level VQ proves to be effective for INCs detection and segmentation, as well as computationally efficient compared to existing approaches. False-positive (FP) reduction is conducted via rule-based filtering operations in combination with a feature-based support vector machine classifier. The proposed system was validated on 205 patient cases from the publically available on-line LIDC (Lung Image Database Consortium) database, with each case having at least one juxta-pleural nodule annotation. Experimental results demonstrated that our CADe system obtained an overall sensitivity of 82.7% at a specificity of 4 FPs/scan, and 89.2% sensitivity at 4.14 FPs/scan for the classification of juxta-pleural INCs only. With respect to comparable CADe systems, the proposed system shows outperformance and demonstrates its potential for fast and adaptive detection of pulmonary nodules via CT imaging. PMID:25486657

  6. A visual data-mining approach using 3D thoracic CT images for classification between benign and malignant pulmonary nodules

    NASA Astrophysics Data System (ADS)

    Kawata, Yoshiki; Niki, Noboru; Ohamatsu, Hironobu; Kusumoto, Masahiko; Kakinuma, Ryutaro; Mori, Kiyoshi; Yamada, K.; Nishiyama, Hiroyuki; Eguchi, Kenji; Kaneko, Masahiro; Moriyama, Noriyuki

    2003-05-01

    This paper presents a visual data-mining approach to assist physicians for classification between benign and malignant pulmonary nodules. This approach retrieves and displays nodules which exhibit morphological and internal profiles consistent to the nodule in question. It uses a three-dimensional (3-D) CT image database of pulmonary nodules for which diagnosis is known. The central module in this approach makes possible analysis of the query nodule image and extraction of the features of interest: shape, surrounding structure, and internal structure of the nodules. The nodule shape is characterized by principal axes, while the surrounding and internal structure is represented by the distribution pattern of CT density and 3-D curvature indexes. The nodule representation is then applied to a similarity measure such as a correlation coefficient. For each query case, we sort all the nodules of the database from most to less similar ones. By applying the retrieval method to our database, we present its feasibility to search the similar 3-D nodule images.

  7. CT angiography - chest

    MedlinePlus

    Computed tomography angiography - thorax; CTA - lungs; Pulmonary embolism - CTA chest; Thoracic aortic aneurysm - CTA chest; Venous thromboembolism - CTA lung; Blood clot - CTA lung; Embolus - CTA lung; CT ...

  8. 4D flow imaging with MRI

    PubMed Central

    Stankovic, Zoran; Allen, Bradley D.; Garcia, Julio; Jarvis, Kelly B.

    2014-01-01

    Magnetic resonance imaging (MRI) has become an important tool for the clinical evaluation of patients with cardiovascular disease. Since its introduction in the late 1980s, 2-dimensional phase contrast MRI (2D PC-MRI) has become a routine part of standard-of-care cardiac MRI for the assessment of regional blood flow in the heart and great vessels. More recently, time-resolved PC-MRI with velocity encoding along all three flow directions and three-dimensional (3D) anatomic coverage (also termed ‘4D flow MRI’) has been developed and applied for the evaluation of cardiovascular hemodynamics in multiple regions of the human body. 4D flow MRI allows for the comprehensive evaluation of complex blood flow patterns by 3D blood flow visualization and flexible retrospective quantification of flow parameters. Recent technical developments, including the utilization of advanced parallel imaging techniques such as k-t GRAPPA, have resulted in reasonable overall scan times, e.g., 8-12 minutes for 4D flow MRI of the aorta and 10-20 minutes for whole heart coverage. As a result, the application of 4D flow MRI in a clinical setting has become more feasible, as documented by an increased number of recent reports on the utility of the technique for the assessment of cardiac and vascular hemodynamics in patient studies. A number of studies have demonstrated the potential of 4D flow MRI to provide an improved assessment of hemodynamics which might aid in the diagnosis and therapeutic management of cardiovascular diseases. The purpose of this review is to describe the methods used for 4D flow MRI acquisition, post-processing and data analysis. In addition, the article provides an overview of the clinical applications of 4D flow MRI and includes a review of applications in the heart, thoracic aorta and hepatic system. PMID:24834414

  9. Statistical modeling of 4D respiratory lung motion using diffeomorphic image registration.

    PubMed

    Ehrhardt, Jan; Werner, René; Schmidt-Richberg, Alexander; Handels, Heinz

    2011-02-01

    Modeling of respiratory motion has become increasingly important in various applications of medical imaging (e.g., radiation therapy of lung cancer). Current modeling approaches are usually confined to intra-patient registration of 3D image data representing the individual patient's anatomy at different breathing phases. We propose an approach to generate a mean motion model of the lung based on thoracic 4D computed tomography (CT) data of different patients to extend the motion modeling capabilities. Our modeling process consists of three steps: an intra-subject registration to generate subject-specific motion models, the generation of an average shape and intensity atlas of the lung as anatomical reference frame, and the registration of the subject-specific motion models to the atlas in order to build a statistical 4D mean motion model (4D-MMM). Furthermore, we present methods to adapt the 4D mean motion model to a patient-specific lung geometry. In all steps, a symmetric diffeomorphic nonlinear intensity-based registration method was employed. The Log-Euclidean framework was used to compute statistics on the diffeomorphic transformations. The presented methods are then used to build a mean motion model of respiratory lung motion using thoracic 4D CT data sets of 17 patients. We evaluate the model by applying it for estimating respiratory motion of ten lung cancer patients. The prediction is evaluated with respect to landmark and tumor motion, and the quantitative analysis results in a mean target registration error (TRE) of 3.3 ±1.6 mm if lung dynamics are not impaired by large lung tumors or other lung disorders (e.g., emphysema). With regard to lung tumor motion, we show that prediction accuracy is independent of tumor size and tumor motion amplitude in the considered data set. However, tumors adhering to non-lung structures degrade local lung dynamics significantly and the model-based prediction accuracy is lower in these cases. The statistical respiratory

  10. A Prospective Evaluation of Staging and Target Volume Definition of Lymph Nodes by {sup 18}FDG PET/CT in Patients With Squamous Cell Carcinoma of Thoracic Esophagus

    SciTech Connect

    Yu Wen; Fu Xiaolong; Zhang Yingjian; Xiang Jiaqing; Shen Lei; Chang, Joe Y.

    2011-12-01

    Purpose: To determine an optimal standardized uptake value (SUV) threshold for detecting lymph node (LN) metastases in esophageal cancer using {sup 18}F-Fluorodeoxyglucose positron emission tomography/computer tomography ({sup 18}FDG PET/CT) and to define the resulting nodal target volume, using histopathology as a 'gold standard.' Methods: Sixteen patients with esophageal squamous cell carcinoma who underwent radical esophagectomy and three-field LN dissection after {sup 18}FDG PET/CT and CT scans were enrolled into this study. Locations of LN groups were recorded according to a uniform LN map. Diagnostic performance of different SUV thresholds was assessed by receiver operating characteristic analysis. The optimal cutoff SUV was determined by plotting the false-negative rate (FNR) and false-positive rate (FPR), the sum of both error rates (FNR+FPR), and accuracy against a hypothetical SUV threshold. For each patient, nodal gross tumor volumes (GTVNs) were generated with CT alone (GTVNCT), PET/CT (GTVNPET), and pathologic data (GTVNpath). GTVNCT or GTVNPET was compared with GTVNpath by means of a conformity index (CI), which is the intersection of the two GTVNs divided by the sum of them minus the intersection, e.g., CI{sub CT} and {sub path} = GTVN{sub CT} and {sub path}/(GTVN{sub CT}+ GTVN{sub path} - GTVN{sub CT} and {sub path}). Results: LN metastases occurred in 21 LN groups among the 144 specimens taken from the 16 patients. The area under the receiver operating characteristic curve was 0.9017 {+-} 0.0410. The plot of error rates showed a minimum of FNR+FPR for an SUV of 2.36, at which the sensitivity, specificity, and accuracy were 76.19%, 95.93%, and 93.06%, respectively, whereas those of CT were 33.33%, 94.31%, and 85.42% (p values: 0.0117, 0.7539, and 0.0266). Mean GTVN{sub CT}, GTVN{sub PET}, and GTVN{sub path} were 1.52 {+-} 2.38, 2.82 {+-} 4.51, and 2.68 {+-} 4.16cm{sup 3}, respectively. Mean CI{sub CT} and {sub path} and CI{sub PET} and {sub path

  11. Advances in 4D radiation therapy for managing respiration: part II - 4D treatment planning.

    PubMed

    Rosu, Mihaela; Hugo, Geoffrey D

    2012-12-01

    The development of 4D CT imaging technology made possible the creation of patient models that are reflective of respiration-induced anatomical changes by adding a temporal dimension to the conventional 3D, spatial-only, patient description. This had opened a new venue for treatment planning and radiation delivery, aimed at creating a comprehensive 4D radiation therapy process for moving targets. Unlike other breathing motion compensation strategies (e.g. breath-hold and gating techniques), 4D radiotherapy assumes treatment delivery over the entire respiratory cycle - an added bonus for both patient comfort and treatment time efficiency. The time-dependent positional and volumetric information holds the promise for optimal, highly conformal, radiotherapy for targets experiencing movements caused by respiration, with potentially elevated dose prescriptions and therefore higher cure rates, while avoiding the uninvolved nearby structures. In this paper, the current state of the 4D treatment planning is reviewed, from theory to the established practical routine. While the fundamental principles of 4D radiotherapy are well defined, the development of a complete, robust and clinically feasible process still remains a challenge, imposed by limitations in the available treatment planning and radiation delivery systems.

  12. Helical (spiral) CT in the evaluation of emergent thoracic aortic syndromes. Traumatic aortic rupture, aortic aneurysm, aortic dissection, intramural hematoma, and penetrating atherosclerotic ulcer.

    PubMed

    Ledbetter, S; Stuk, J L; Kaufman, J A

    1999-05-01

    For the near future, CT will play the critical and dominant role in the evaluation of patients presenting with emergent aortic syndromes. Its convenience, accuracy, and utility in the rapid evaluation of not just the aorta, but the entire thorax, make it ideally suited for use in emergency settings. Further benefits are likely to be realized in speed and resolution with multislice CT, although it is as yet not widely available.

  13. Ferret thoracic anatomy by 2-deoxy-2-(18F)fluoro-D-glucose (18F-FDG) positron emission tomography/computed tomography (18F-FDG PET/CT) imaging.

    PubMed

    Wu, Albert; Zheng, Huaiyu; Kraenzle, Jennifer; Biller, Ashley; Vanover, Carol D; Proctor, Mary; Sherwood, Leslie; Steffen, Marlene; Ng, Chin; Mollura, Daniel J; Jonsson, Colleen B

    2012-01-01

    The domestic ferret (Mustela putorius furo) has been a long-standing animal model used in the evaluation and treatment of human diseases. Molecular imaging techniques such as 2-deoxy-2-((18)F)fluoro-D-glucose ((18)F-FDG) positron emission tomography (PET) would be an invaluable method of tracking disease in vivo, but this technique has not been reported in the literature. Thus, the aim of this study was to establish baseline imaging characteristics of PET/computed tomography (CT) with (18)F-FDG in the ferret model. Twelve healthy female ferrets were anesthetized and underwent combined PET/CT scanning. After the images were fused, volumes of interest (VOIs) were generated in the liver, heart, thymus, and bilateral lung fields. For each VOI, standardized uptake values (SUVs) were calculated. Additional comparisons were made between radiotracer uptake periods (60, 90, and >90 minutes), intravenous and intraperitoneal injections of (18)F-FDG, and respiratory gated and ungated acquisitions. Pulmonary structures and the surrounding thoracic and upper abdominal anatomy were readily identified on the CT scans of all ferrets and were successfully fused with PET. VOIs were created in various tissues with the following SUV calculations: heart (maximum standardized uptake value [SUV(Max)] 8.60, mean standardized uptake value [SUV(Mean)] 5.42), thymus (SUV(Max) 3.86, SUV(Mean) 2.59), liver (SUV(Max) 1.37, SUV(Mean) 0.99), right lung (SUV(Max) 0.92, SUV(Mean) 0.56), and left lung (SUV(Max) 0.88, SUV(Mean) 0.51). Sixty- to 90-minute uptake periods were sufficient to separate tissues based on background SUV activity. No gross differences in image quality were seen between intraperitoneal and intravenous injections of (18)F-FDG. Respiratory gating also did not have a significant impact on image quality of lung parenchyma. The authors concluded that (18)F-FDG PET and CT imaging can be performed successfully in normal healthy ferrets with the parameters identified in this study. They

  14. Ferret Thoracic Anatomy by 2-Deoxy-2-(18F)Fluoro-D-Glucose (18F-FDG) Positron Emission Tomography/Computed Tomography (18F-FDG PET/CT) Imaging

    PubMed Central

    Wu, Albert; Zheng, Huaiyu; Kraenzle, Jennifer; Biller, Ashley; Vanover, Carol D.; Proctor, Mary; Sherwood, Leslie; Steffen, Marlene; Ng, Chin; Mollura, Daniel J.; Jonsson, Colleen B.

    2013-01-01

    The domestic ferret (Mustela putorius furo) has been a long-standing animal model used in the evaluation and treatment of human diseases. Molecular imaging techniques such as 2-deoxy-2-(18F)fluoro-D-glucose (18F-FDG) positron emission tomography (PET) would be an invaluable method of tracking disease in vivo, but this technique has not been reported in the literature. Thus, the aim of this study was to establish baseline imaging characteristics of PET/computed tomography (CT) with 18F-FDG in the ferret model. Twelve healthy female ferrets were anesthetized and underwent combined PET/CT scanning. After the images were fused, volumes of interest (VOIs) were generated in the liver, heart, thymus, and bilateral lung fields. For each VOI, standardized uptake values (SUVs) were calculated. Additional comparisons were made between radiotracer uptake periods (60, 90, and >90 minutes), intravenous and intraperitoneal injections of 18F-FDG, and respiratory gated and ungated acquisitions. Pulmonary structures and the surrounding thoracic and upper abdominal anatomy were readily identified on the CT scans of all ferrets and were successfully fused with PET. VOIs were created in various tissues with the following SUV calculations: heart (maximum standardized uptake value [SUVMax] 8.60, mean standardized uptake value [SUVMean] 5.42), thymus (SUVMax 3.86, SUVMean 2.59), liver (SUVMax 1.37, SUVMean 0.99), right lung (SUVMax 0.92, SUVMean 0.56), and left lung (SUVMax 0.88, SUVMean 0.51). Sixty- to 90-minute uptake periods were sufficient to separate tissues based on background SUV activity. No gross differences in image quality were seen between intraperitoneal and intravenous injections of 18F-FDG. Respiratory gating also did not have a significant impact on image quality of lung parenchyma. The authors concluded that 18F-FDG PET and CT imaging can be performed successfully in normal healthy ferrets with the parameters identified in this study. They obtained similar imaging

  15. [Thoracic involvement in Behçet's vasculitis].

    PubMed

    Zidi, A; Ben Miled Mrad, K; Hantous, S; Nouira, K; Mestiri, I; Mrad, S

    2006-03-01

    Thoracic involvement of Behcet's disease is unusual but serious. It is related to the well known vascular tropism of the disease. It may involve the superior vena cava, pulmonary arteries, aorta and subclavian vessels. Imaging is useful for diagnosis and assess the degree of thoracic involvement. CT scan and MRI are obviously more accurate than angiography. The spectrum of thoracic manifestations of the disease is presented based on a review of 22 cases.

  16. A study of respiration-correlated cone-beam CT scans to correct target positioning errors in radiotherapy of thoracic cancer

    SciTech Connect

    Santoro, J. P.; McNamara, J.; Yorke, E.; Pham, H.; Rimner, A.; Rosenzweig, K. E.; Mageras, G. S.

    2012-10-15

    Purpose: There is increasingly widespread usage of cone-beam CT (CBCT) for guiding radiation treatment in advanced-stage lung tumors, but difficulties associated with daily CBCT in conventionally fractionated treatments include imaging dose to the patient, increased workload and longer treatment times. Respiration-correlated cone-beam CT (RC-CBCT) can improve localization accuracy in mobile lung tumors, but further increases the time and workload for conventionally fractionated treatments. This study investigates whether RC-CBCT-guided correction of systematic tumor deviations in standard fractionated lung tumor radiation treatments is more effective than 2D image-based correction of skeletal deviations alone. A second study goal compares respiration-correlated vs respiration-averaged images for determining tumor deviations. Methods: Eleven stage II-IV nonsmall cell lung cancer patients are enrolled in an IRB-approved prospective off-line protocol using RC-CBCT guidance to correct for systematic errors in GTV position. Patients receive a respiration-correlated planning CT (RCCT) at simulation, daily kilovoltage RC-CBCT scans during the first week of treatment and weekly scans thereafter. Four types of correction methods are compared: (1) systematic error in gross tumor volume (GTV) position, (2) systematic error in skeletal anatomy, (3) daily skeletal corrections, and (4) weekly skeletal corrections. The comparison is in terms of weighted average of the residual GTV deviations measured from the RC-CBCT scans and representing the estimated residual deviation over the treatment course. In the second study goal, GTV deviations computed from matching RCCT and RC-CBCT are compared to deviations computed from matching respiration-averaged images consisting of a CBCT reconstructed using all projections and an average-intensity-projection CT computed from the RCCT. Results: Of the eleven patients in the GTV-based systematic correction protocol, two required no correction

  17. True 4D Image Denoising on the GPU.

    PubMed

    Eklund, Anders; Andersson, Mats; Knutsson, Hans

    2011-01-01

    The use of image denoising techniques is an important part of many medical imaging applications. One common application is to improve the image quality of low-dose (noisy) computed tomography (CT) data. While 3D image denoising previously has been applied to several volumes independently, there has not been much work done on true 4D image denoising, where the algorithm considers several volumes at the same time. The problem with 4D image denoising, compared to 2D and 3D denoising, is that the computational complexity increases exponentially. In this paper we describe a novel algorithm for true 4D image denoising, based on local adaptive filtering, and how to implement it on the graphics processing unit (GPU). The algorithm was applied to a 4D CT heart dataset of the resolution 512  × 512  × 445  × 20. The result is that the GPU can complete the denoising in about 25 minutes if spatial filtering is used and in about 8 minutes if FFT-based filtering is used. The CPU implementation requires several days of processing time for spatial filtering and about 50 minutes for FFT-based filtering. The short processing time increases the clinical value of true 4D image denoising significantly.

  18. TU-F-17A-01: BEST IN PHYSICS (JOINT IMAGING-THERAPY) - An Automatic Toolkit for Efficient and Robust Analysis of 4D Respiratory Motion

    SciTech Connect

    Wei, J; Yuan, A; Li, G

    2014-06-15

    Purpose: To provide an automatic image analysis toolkit to process thoracic 4-dimensional computed tomography (4DCT) and extract patient-specific motion information to facilitate investigational or clinical use of 4DCT. Methods: We developed an automatic toolkit in MATLAB to overcome the extra workload from the time dimension in 4DCT. This toolkit employs image/signal processing, computer vision, and machine learning methods to visualize, segment, register, and characterize lung 4DCT automatically or interactively. A fully-automated 3D lung segmentation algorithm was designed and 4D lung segmentation was achieved in batch mode. Voxel counting was used to calculate volume variations of the torso, lung and its air component, and local volume changes at the diaphragm and chest wall to characterize breathing pattern. Segmented lung volumes in 12 patients are compared with those from a treatment planning system (TPS). Voxel conversion was introduced from CT# to other physical parameters, such as gravity-induced pressure, to create a secondary 4D image. A demon algorithm was applied in deformable image registration and motion trajectories were extracted automatically. Calculated motion parameters were plotted with various templates. Machine learning algorithms, such as Naive Bayes and random forests, were implemented to study respiratory motion. This toolkit is complementary to and will be integrated with the Computational Environment for Radiotherapy Research (CERR). Results: The automatic 4D image/data processing toolkit provides a platform for analysis of 4D images and datasets. It processes 4D data automatically in batch mode and provides interactive visual verification for manual adjustments. The discrepancy in lung volume calculation between this and the TPS is <±2% and the time saving is by 1–2 orders of magnitude. Conclusion: A framework of 4D toolkit has been developed to analyze thoracic 4DCT automatically or interactively, facilitating both investigational

  19. SU-E-J-113: Effects of Deformable Registration On First-Order Texture Maps Calculated From Thoracic Lung CT Scans

    SciTech Connect

    Smith, C; Cunliffe, A; Al-Hallaq, H; Armato, S

    2015-06-15

    Purpose: To determine the stability of eight first-order texture features following the deformable registration of serial computed tomography (CT) scans. Methods: CT scans at two different time points from 10 patients deemed to have no lung abnormalities by a radiologist were collected. Following lung segmentation using an in-house program, texture maps were calculated from 32×32-pixel regions of interest centered at every pixel in the lungs. The texture feature value of the ROI was assigned to the center pixel of the ROI in the corresponding location of the texture map. Pixels in the square ROI not contained within the segmented lung were not included in the calculation. To quantify the agreement between ROI texture features in corresponding pixels of the baseline and follow-up texture maps, the Fraunhofer MEVIS EMPIRE10 deformable registration algorithm was used to register the baseline and follow-up scans. Bland-Altman analysis was used to compare registered scan pairs by computing normalized bias (nBias), defined as the feature value change normalized to the mean feature value, and normalized range of agreement (nRoA), defined as the range spanned by the 95% limits of agreement normalized to the mean feature value. Results: Each patient’s scans contained between 6.8–15.4 million ROIs. All of the first-order features investigated were found to have an nBias value less than 0.04% and an nRoA less than 19%, indicating that the variability introduced by deformable registration was low. Conclusion: The eight first-order features investigated were found to be registration stable. Changes in CT texture maps could allow for temporal-spatial evaluation of the evolution of lung abnormalities relating to a variety of diseases on a patient-by-patient basis. SGA and HA receives royalties and licensing fees through the University of Chicago for computer-aided diagnosis technology. Research reported in this publication was supported by the National Institute Of General

  20. Evaluation of 1D, 2D and 3D nodule size estimation by radiologists for spherical and non-spherical nodules through CT thoracic phantom imaging

    NASA Astrophysics Data System (ADS)

    Petrick, Nicholas; Kim, Hyun J. Grace; Clunie, David; Borradaile, Kristin; Ford, Robert; Zeng, Rongping; Gavrielides, Marios A.; McNitt-Gray, Michael F.; Fenimore, Charles; Lu, Z. Q. John; Zhao, Binsheng; Buckler, Andrew J.

    2011-03-01

    The purpose of this work was to estimate bias in measuring the size of spherical and non-spherical lesions by radiologists using three sizing techniques under a variety of simulated lesion and reconstruction slice thickness conditions. We designed a reader study in which six radiologists estimated the size of 10 synthetic nodules of various sizes, shapes and densities embedded within a realistic anthropomorphic thorax phantom from CT scan data. In this manuscript we report preliminary results for the first four readers (Reader 1-4). Two repeat CT scans of the phantom containing each nodule were acquired using a Philips 16-slice scanner at a 0.8 and 5 mm slice thickness. The readers measured the sizes of all nodules for each of the 40 resulting scans (10 nodules x 2 slice thickness x 2 repeat scans) using three sizing techniques (1D longest in-slice dimension; 2D area from longest in-slice dimension and corresponding longest perpendicular dimension; 3D semi-automated volume) in each of 2 reading sessions. The normalized size was estimated for each sizing method and an inter-comparison of bias among methods was performed. The overall relative biases (standard deviation) of the 1D, 2D and 3D methods for the four readers subset (Readers 1-4) were -13.4 (20.3), -15.3 (28.4) and 4.8 (21.2) percentage points, respectively. The relative biases for the 3D volume sizing method was statistically lower than either the 1D or 2D method (p<0.001 for 1D vs. 3D and 2D vs. 3D).

  1. American Thoracic Society

    MedlinePlus

    ... Infections Nursing Pediatrics Pulmonary Circulation Pulmonary Rehabilitation Respiratory Cell & Molecular Biology Respiratory Structure & Function Sleep & Respiratory Neurobiology Thoracic Oncology ...

  2. Multiplanar CT of the spine

    SciTech Connect

    Rothman, S.L.G.; Glenn, W.V.

    1985-01-01

    This book contains 16 chapters. Some of the topics are: CT of the Sacrum, The Postoperative Spine, Film Organizations and Case Reporting, Degeneration and Disc Disease of the Intervertebral Joint, Lumbar Spinal Stenosis, and Cervical and Thoracic Spine.

  3. Airway Segmentation and Centerline Extraction from Thoracic CT – Comparison of a New Method to State of the Art Commercialized Methods

    PubMed Central

    Reynisson, Pall Jens; Scali, Marta; Smistad, Erik; Hofstad, Erlend Fagertun; Leira, Håkon Olav; Lindseth, Frank; Nagelhus Hernes, Toril Anita; Amundsen, Tore; Sorger, Hanne; Langø, Thomas

    2015-01-01

    Introduction Our motivation is increased bronchoscopic diagnostic yield and optimized preparation, for navigated bronchoscopy. In navigated bronchoscopy, virtual 3D airway visualization is often used to guide a bronchoscopic tool to peripheral lesions, synchronized with the real time video bronchoscopy. Visualization during navigated bronchoscopy, the segmentation time and methods, differs. Time consumption and logistics are two essential aspects that need to be optimized when integrating such technologies in the interventional room. We compared three different approaches to obtain airway centerlines and surface. Method CT lung dataset of 17 patients were processed in Mimics (Materialize, Leuven, Belgium), which provides a Basic module and a Pulmonology module (beta version) (MPM), OsiriX (Pixmeo, Geneva, Switzerland) and our Tube Segmentation Framework (TSF) method. Both MPM and TSF were evaluated with reference segmentation. Automatic and manual settings allowed us to segment the airways and obtain 3D models as well as the centrelines in all datasets. We compared the different procedures by user interactions such as number of clicks needed to process the data and quantitative measures concerning the quality of the segmentation and centrelines such as total length of the branches, number of branches, number of generations, and volume of the 3D model. Results The TSF method was the most automatic, while the Mimics Pulmonology Module (MPM) and the Mimics Basic Module (MBM) resulted in the highest number of branches. MPM is the software which demands the least number of clicks to process the data. We found that the freely available OsiriX was less accurate compared to the other methods regarding segmentation results. However, the TSF method provided results fastest regarding number of clicks. The MPM was able to find the highest number of branches and generations. On the other hand, the TSF is fully automatic and it provides the user with both segmentation of the

  4. MR imaging of the thoracic aorta.

    PubMed

    Lohan, Derek G; Krishnam, Mayil; Saleh, Roya; Tomasian, Anderanik; Finn, J Paul

    2008-05-01

    MR imaging has been incorporated into the diagnostic algorithm for suspected thoracic aortic pathology, challenging CT and invasive catheter angiography as investigations of choice. Techniques, including spin echo, 3-D steady-state free precession, cardiac cine imaging, phase-contrast flow quantification, and high-resolution contrast-enhanced magnetic resonance angiography, are poised to trump other single competitive modalities. The proliferation of 3-tesla systems has advanced the performance of magnetic resonance, aided by parallel imaging techniques, multiarray surface coils, and powerful gradient coils. This article considers the current status of MR imaging in evaluation of the thoracic aorta, with reference to common clinical indications in clinical practice.

  5. Aortobronchial Fistula after Thoracic Endovascular Aortic Repair (TEVAR) for Descending Thoracic Aortic Aneurysm.

    PubMed

    Melvan, John Nicholas; DeLaRosa, Jacob; Vasquez, Julio C

    2017-03-07

    Continued enlargement of the aneurysm sac after thoracic endovascular aortic repair (TEVAR) is a known risk after endovascular treatment of thoracic aortic aneurysms. For this reason, periodic outpatient follow-up is required to identify situations that require repair. Here, we describe an aortobronchial fistula (ABF) in a patient lost to follow-up, that presented 3 years after an elective TEVAR done for a primary, descending thoracic aortic aneurysm. Our patient arrived in extremis and suffered massive hemoptysis leading to her demise. Computed tomography (CT) angiogram near the time of her death demonstrated a bleeding ABF immediately distal to her previous TEVAR repair. Aortic aneurysmal disease remains life threatening even after repair. Improved endovascular techniques and devices have resulted in decreased need for reintervention. However, this case demonstrates the risk of thoracic aortic disease progression and highlights the importance of establishing consistent, long-term follow-up after TEVAR.

  6. Validation of a 4D-PET Maximum Intensity Projection for Delineation of an Internal Target Volume

    SciTech Connect

    Callahan, Jason; Kron, Tomas; Schneider-Kolsky, Michal; Dunn, Leon; Thompson, Mick; Siva, Shankar; Aarons, Yolanda; Binns, David; Hicks, Rodney J.

    2013-07-15

    Purpose: The delineation of internal target volumes (ITVs) in radiation therapy of lung tumors is currently performed by use of either free-breathing (FB) {sup 18}F-fluorodeoxyglucose-positron emission tomography-computed tomography (FDG-PET/CT) or 4-dimensional (4D)-CT maximum intensity projection (MIP). In this report we validate the use of 4D-PET-MIP for the delineation of target volumes in both a phantom and in patients. Methods and Materials: A phantom with 3 hollow spheres was prepared surrounded by air then water. The spheres and water background were filled with a mixture of {sup 18}F and radiographic contrast medium. A 4D-PET/CT scan was performed of the phantom while moving in 4 different breathing patterns using a programmable motion device. Nine patients with an FDG-avid lung tumor who underwent FB and 4D-PET/CT and >5 mm of tumor motion were included for analysis. The 3 spheres and patient lesions were contoured by 2 contouring methods (40% of maximum and PET edge) on the FB-PET, FB-CT, 4D-PET, 4D-PET-MIP, and 4D-CT-MIP. The concordance between the different contoured volumes was calculated using a Dice coefficient (DC). The difference in lung tumor volumes between FB-PET and 4D-PET volumes was also measured. Results: The average DC in the phantom using 40% and PET edge, respectively, was lowest for FB-PET/CT (DCAir = 0.72/0.67, DCBackground 0.63/0.62) and highest for 4D-PET/CT-MIP (DCAir = 0.84/0.83, DCBackground = 0.78/0.73). The average DC in the 9 patients using 40% and PET edge, respectively, was also lowest for FB-PET/CT (DC = 0.45/0.44) and highest for 4D-PET/CT-MIP (DC = 0.72/0.73). In the 9 lesions, the target volumes of the FB-PET using 40% and PET edge, respectively, were on average 40% and 45% smaller than the 4D-PET-MIP. Conclusion: A 4D-PET-MIP produces volumes with the highest concordance with 4D-CT-MIP across multiple breathing patterns and lesion sizes in both a phantom and among patients. Freebreathing PET/CT consistently

  7. Deblurring of breathing motion artifacts in thoracic PET images by deconvolution methods

    SciTech Connect

    Naqa, Issam El; Low, Daniel A.; Bradley, Jeffrey D.; Vicic, Milos; Deasy, Joseph O.

    2006-10-15

    results show that the proposed method provides a feasible framework for improving PET thoracic images, without the need for gated/4-D PET imaging, when 4-D CT is available to estimate tumor motion.

  8. Noninvasive 4D pressure difference mapping derived from 4D flow MRI in patients with repaired aortic coarctation: comparison with young healthy volunteers.

    PubMed

    Rengier, Fabian; Delles, Michael; Eichhorn, Joachim; Azad, Yoo-Jin; von Tengg-Kobligk, Hendrik; Ley-Zaporozhan, Julia; Dillmann, Rüdiger; Kauczor, Hans-Ulrich; Unterhinninghofen, Roland; Ley, Sebastian

    2015-04-01

    To assess spatial and temporal pressure characteristics in patients with repaired aortic coarctation compared to young healthy volunteers using time-resolved velocity-encoded three-dimensional phase-contrast magnetic resonance imaging (4D flow MRI) and derived 4D pressure difference maps. After in vitro validation against invasive catheterization as gold standard, 4D flow MRI of the thoracic aorta was performed at 1.5T in 13 consecutive patients after aortic coarctation repair without recoarctation and 13 healthy volunteers. Using in-house developed processing software, 4D pressure difference maps were computed based on the Navier-Stokes equation. Pressure difference amplitudes, maximum slope of pressure amplitudes and spatial pressure range at mid systole were retrospectively measured by three readers, and twice by one reader to assess inter- and intraobserver agreement. In vitro, pressure differences derived from 4D flow MRI showed excellent agreement to invasive catheter measurements. In vivo, pressure difference amplitudes, maximum slope of pressure difference amplitudes and spatial pressure range at mid systole were significantly increased in patients compared to volunteers in the aortic arch, the proximal descending and the distal descending thoracic aorta (p < 0.05). Greatest differences occurred in the proximal descending aorta with values of the three parameters for patients versus volunteers being 19.7 ± 7.5 versus 10.0 ± 2.0 (p < 0.001), 10.9 ± 10.4 versus 1.9 ± 0.4 (p = 0.002), and 8.7 ± 6.3 versus 1.6 ± 0.9 (p < 0.001). Inter- and intraobserver agreements were excellent (p < 0.001). Noninvasive 4D pressure difference mapping derived from 4D flow MRI enables detection of altered intraluminal aortic pressures and showed significant spatial and temporal changes in patients with repaired aortic coarctation.

  9. 4-D OCT in Developmental Cardiology

    NASA Astrophysics Data System (ADS)

    Jenkins, Michael W.; Rollins, Andrew M.

    Although strong evidence exists to suggest that altered cardiac function can lead to CHDs, few studies have investigated the influential role of cardiac function and biophysical forces on the development of the cardiovascular system due to a lack of proper in vivo imaging tools. 4-D imaging is needed to decipher the complex spatial and temporal patterns of biomechanical forces acting upon the heart. Numerous solutions over the past several years have demonstrated 4-D OCT imaging of the developing cardiovascular system. This chapter will focus on these solutions and explain their context in the evolution of 4-D OCT imaging. The first sections describe the relevant techniques (prospective gating, direct 4-D imaging, retrospective gating), while later sections focus on 4-D Doppler imaging and measurements of force implementing 4-D OCT Doppler. Finally, the techniques are summarized, and some possible future directions are discussed.

  10. A sinogram warping strategy for pre-reconstruction 4D PET optimization.

    PubMed

    Gianoli, Chiara; Riboldi, Marco; Fontana, Giulia; Kurz, Christopher; Parodi, Katia; Baroni, Guido

    2016-03-01

    A novel strategy for 4D PET optimization in the sinogram domain is proposed, aiming at motion model application before image reconstruction ("sinogram warping" strategy). Compared to state-of-the-art 4D-MLEM reconstruction, the proposed strategy is able to optimize the image SNR, avoiding iterative direct and inverse warping procedures, which are typical of the 4D-MLEM algorithm. A full-count statistics sinogram of the motion-compensated 4D PET reference phase is generated by warping the sinograms corresponding to the different PET phases. This is achieved relying on a motion model expressed in the sinogram domain. The strategy was tested on the anthropomorphic 4D PET-CT NCAT phantom in comparison with the 4D-MLEM algorithm, with particular reference to robustness to PET-CT co-registrations artefacts. The MLEM reconstruction of the warped sinogram according to the proposed strategy exhibited better accuracy (up to +40.90 % with respect to the ideal value), whereas images reconstructed according to the 4D-MLEM reconstruction resulted in less noisy (down to -26.90 % with respect to the ideal value) but more blurred. The sinogram warping strategy demonstrates advantages with respect to 4D-MLEM algorithm. These advantages are paid back by introducing approximation of the deformation field, and further efforts are required to mitigate the impact of such an approximation in clinical 4D PET reconstruction.

  11. 4D VMAT, gated VMAT, and 3D VMAT for stereotactic body radiation therapy in lung

    NASA Astrophysics Data System (ADS)

    Chin, E.; Loewen, S. K.; Nichol, A.; Otto, K.

    2013-02-01

    Four-dimensional volumetric modulated arc therapy (4D VMAT) is a treatment strategy for lung cancers that aims to exploit relative target and tissue motion to improve organ at risk (OAR) sparing. The algorithm incorporates the entire patient respiratory cycle using 4D CT data into the optimization process. Resulting treatment plans synchronize the delivery of each beam aperture to a specific phase of target motion. Stereotactic body radiation therapy treatment plans for 4D VMAT, gated VMAT, and 3D VMAT were generated on three patients with non-small cell lung cancer. Tumour motion ranged from 1.4-3.4 cm. The dose and fractionation scheme was 48 Gy in four fractions. A B-spline transformation model registered the 4D CT images. 4D dose volume histograms (4D DVH) were calculated from total dose accumulated at the maximum exhalation. For the majority of OARs, gated VMAT achieved the most radiation sparing but treatment times were 77-148% longer than 3D VMAT. 4D VMAT plan qualities were comparable to gated VMAT, but treatment times were only 11-25% longer than 3D VMAT. 4D VMAT's improvement of healthy tissue sparing can allow for further dose escalation. Future study could potentially adapt 4D VMAT to irregular patient breathing patterns.

  12. Rare case of thoracic kidney detected by renal scintigraphy

    PubMed Central

    Natarajan, Aravintho; Agrawal, Archi; Purandare, Nilendu; Shah, Sneha; Rangarajan, Venkatesh

    2016-01-01

    Intrathoracic kidney is a rare congenital abnormality with lowest frequency among all renal ectopias. Patients with thoracic kidneys are usually asymptomatic, and the condition is usually discovered incidentally during radiological evaluation for other conditions or during thoracic surgery. We report a case of a 62-year-old male who was referred to our department for renal scintigraphy for a nonvisualized left kidney on ultrasonography report. Both Tc-99m dimercaptosuccinic acid and diethylenetriaminepentaacetic acid scans revealed a left thoracic kidney which was confirmed by CT scan of the thorax and abdomen. PMID:27385896

  13. Advances in 4D radiation therapy for managing respiration: part I - 4D imaging.

    PubMed

    Hugo, Geoffrey D; Rosu, Mihaela

    2012-12-01

    Techniques for managing respiration during imaging and planning of radiation therapy are reviewed, concentrating on free-breathing (4D) approaches. First, we focus on detailing the historical development and basic operational principles of currently-available "first generation" 4D imaging modalities: 4D computed tomography, 4D cone beam computed tomography, 4D magnetic resonance imaging, and 4D positron emission tomography. Features and limitations of these first generation systems are described, including necessity of breathing surrogates for 4D image reconstruction, assumptions made in acquisition and reconstruction about the breathing pattern, and commonly-observed artifacts. Both established and developmental methods to deal with these limitations are detailed. Finally, strategies to construct 4D targets and images and, alternatively, to compress 4D information into static targets and images for radiation therapy planning are described.

  14. SU-E-J-209: Geometric Distortion at 3T in a Commercial 4D MRI-Compatible Phantom

    SciTech Connect

    Fatemi-Ardekani, A; Wronski, M; Kim, A; Stanisz, G; Sarfehnia, A; Keller, B

    2015-06-15

    Purpose: There are very few commercial 4D phantoms that are marketed as MRI compatible. We are evaluating one such commercial phantom, made to be used with an MRI-Linear accelerator. The focus of this work is to characterize the geometric distortions produced in this phantom at 3T using 3 clinical MR pulse sequences. Methods: The CIRS MRI-Linac Dynamic Phantom (CIRSTM) under investigation in this study consists of a softwaredriven moving tumour volume within a thorax phantom body and enables dose accumulation by placing a dosimeter within the tumour volume. Our initial investigation is to evaluate the phantom in static mode prior to examining its 4D capability. The water-filled thorax phantom was scanned using a wide-bore Philips 3T Achieva MRI scanner employing a Thoracic xl coil and clinical 2D T1W FFE, 2D T1W TSE and 3D T1W TFE pulse sequences. Each of the MR image sets was rigidly fused with a reference CT image of the phantom employing a rigid registration with 6 degrees of freedom. Geometric distortions between the MR and CT image sets were measured in 3 dimensions at selected points along the periphery of the distortion grid embedded within the phantom body (11.5, 7.5 and 3 cm laterally, ant/post and sup/inf of magnetic isocenter respectively). Results: The maximal measured geometric distortions between the MR and reference CT points of interest were 0.9, 1.8 and 1.3 mm in the lateral, anteriorposterior and cranio-caudal directions, respectively. For all 3 spatial dimensions, the maximal distortions occurred for the FFE pulse sequence. Maximal distortions for the 2D FFE, 2D TSE and 3D TFE sequences were 1, 0.7 and 1.8 mm, respectively. Conclusion: Our initial static investigation of this phantom shows minimal geometric distortions at 3T along the periphery of the embedded grid. CIRS has provided us with a phantom at no charge for evaluation at 3 Tesla.

  15. 4D XCAT phantom for multimodality imaging research

    SciTech Connect

    Segars, W. P.; Sturgeon, G.; Mendonca, S.; Grimes, Jason; Tsui, B. M. W.

    2010-09-15

    Purpose: The authors develop the 4D extended cardiac-torso (XCAT) phantom for multimodality imaging research. Methods: Highly detailed whole-body anatomies for the adult male and female were defined in the XCAT using nonuniform rational B-spline (NURBS) and subdivision surfaces based on segmentation of the Visible Male and Female anatomical datasets from the National Library of Medicine as well as patient datasets. Using the flexibility of these surfaces, the Visible Human anatomies were transformed to match body measurements and organ volumes for a 50th percentile (height and weight) male and female. The desired body measurements for the models were obtained using the PEOPLESIZE program that contains anthropometric dimensions categorized from 1st to the 99th percentile for US adults. The desired organ volumes were determined from ICRP Publication 89 [ICRP, ''Basic anatomical and physiological data for use in radiological protection: reference values,'' ICRP Publication 89 (International Commission on Radiological Protection, New York, NY, 2002)]. The male and female anatomies serve as standard templates upon which anatomical variations may be modeled in the XCAT through user-defined parameters. Parametrized models for the cardiac and respiratory motions were also incorporated into the XCAT based on high-resolution cardiac- and respiratory-gated multislice CT data. To demonstrate the usefulness of the phantom, the authors show example simulation studies in PET, SPECT, and CT using publicly available simulation packages. Results: As demonstrated in the pilot studies, the 4D XCAT (which includes thousands of anatomical structures) can produce realistic imaging data when combined with accurate models of the imaging process. With the flexibility of the NURBS surface primitives, any number of different anatomies, cardiac or respiratory motions or patterns, and spatial resolutions can be simulated to perform imaging research. Conclusions: With the ability to produce

  16. Thoracic Aortic Stent-Graft Placement for Safe Removal of a Malpositioned Pedicle Screw

    SciTech Connect

    Hu Hongtao; Shin, Ji Hoon Hwang, Jae-Yeon; Cho, Young Jun; Ko, Gi-Young; Yoon, Hyun-Ki

    2010-10-15

    We describe a case of percutaneous placement of a thoracic aortic stent-graft for safe removal of a malpositioned pedicle screw in a 52-year-old man. The patient had undergone posterior thoracic spinal instrumentation for pyogenic spondylitis and spinal deformity 8 months previously. Follow-up CT images showed a malpositioned pedicle screw which was abutting the thoracic aorta at the T5 level. After percutaneous stent-graft placement, the malpositioned pedicle screw was safely and successfully removed.

  17. CT and MRI of the thorax

    SciTech Connect

    Zerhouni, E.A.

    1990-01-01

    This book addresses a variety of topics in thoracic imaging, including magnetic resonance (MR) imaging in thoracic lymphoma; focal and high-resolution computed tomography (CT) of diffuse lung disease; imaging and disorders of the pleura, diaphragm, and mediastinum; and the increasingly important topic of the immunocompromised patient. Eight case studies close out the volume.

  18. Los Alamos National Laboratory 4D Database

    SciTech Connect

    Atencio, Julian J.

    2014-05-02

    4D is an integrated development platform - a single product comprised of the components you need to create and distribute professional applications. You get a graphical design environment, SQL database, a programming language, integrated PHP execution, HTTP server, application server, executable generator, and much more. 4D offers multi-platform development and deployment, meaning whatever you create on a Mac can be used on Windows, and vice-versa. Beyond productive development, 4D is renowned for its great flexibility in maintenance and modification of existing applications, and its extreme ease of implementation in its numerous deployment options. Your professional application can be put into production more quickly, at a lower cost, and will always be instantly scalable. 4D makes it easy, whether you're looking to create a classic desktop application, a client-server system, a distributed solution for Web or mobile clients - or all of the above!

  19. Endoscopic thoracic sympathectomy

    MedlinePlus

    Endoscopic thoracic sympathectomy (ETS) is surgery to treat sweating that is much heavier than normal. This condition ... hyperhidrosis . Usually the surgery is used to treat sweating in the palms or face. The sympathetic nerves ...

  20. Society of Thoracic Surgeons

    MedlinePlus

    ... STS Participant User File Research Program Videos Lung Cancer Screening Adoption How to Build Your Academic Career New Technologies in Mitral Valve Replacement Enhanced Recovery Pathways in Thoracic Surgery New STS Clinical Practice Guidelines ...

  1. Thoracic aortic aneurysm

    MedlinePlus

    ... common cause of a thoracic aortic aneurysm is hardening of the arteries . This condition is more common ... aortic aneurysm repair - open Aortic aneurysm repair - endovascular Hardening of the arteries High blood pressure Marfan syndrome ...

  2. Thoracic computed tomography in feline patients without use of chemical restraint.

    PubMed

    Oliveira, Cintia R; Mitchell, Mark A; O'Brien, Robert T

    2011-01-01

    Computed tomography (CT) and thoracic radiography were performed in nonsedated, nonanesthetized, cats with thoracic disease. The final diagnosis was obtained with echocardiography, cytology, histopathology, necropsy, or response to therapy. For CT imaging, cats were in a positioning device using a 16 multislice helical CT system. Fifty-four cats had CT imaging of which 50 had thoracic radiography. The most common diagnoses were lung neoplasia, lower airway disease, and cardiomyopathy (nine each). Other disease groups included mediastinal mass (eight), infection (seven), trauma (four), and hernia (three). CT provided additional correct diagnoses in 28% (14/50) and additional information in 74% (37/50) of the cats. Additional correct diagnoses achieved only with CT were most common for cats with lower airway disease. The most common additional findings with CT were lung nodules (n=4), lung masses (n=4), bronchiectasis (n=4), and mediastinal lymphadenopathy (n=3). Survey CT led to a significant different diagnosis or different prognosis in 20 of the 50 cats that were imaged both modalities. Contrast CT was performed in 19 cats, most commonly in cats with lung neoplasia (n=6), a mediastinal mass (n=4) or an infection (n=3), and provided additional correct diagnosis in two cats not achieved with survey CT. Thoracic CT using a positioning device in diseased awake cats is feasible, safe, and clinically useful.

  3. 4D chromatin dynamics in cycling cells

    PubMed Central

    Strickfaden, Hilmar; Zunhammer, Andreas; van Koningsbruggen, Silvana; Köhler, Daniela

    2010-01-01

    This live cell study of chromatin dynamics in four dimensions (space and time) in cycling human cells provides direct evidence for three hypotheses first proposed by Theodor Boveri in seminal studies of fixed blastomeres from Parascaris equorum embryos: (I) Chromosome territory (CT) arrangements are stably maintained during interphase. (II) Chromosome proximity patterns change profoundly during prometaphase. (III) Similar CT proximity patterns in pairs of daughter nuclei reflect symmetrical chromosomal movements during anaphase and telophase, but differ substantially from the arrangement in mother cell nucleus. Hypothesis I could be confirmed for the majority of interphase cells. A minority, however, showed complex, rotational movements of CT assemblies with large-scale changes of CT proximity patterns, while radial nuclear arrangements were maintained. A new model of chromatin dynamics is proposed. It suggests that long-range DNA-DNA interactions in cell nuclei may depend on a combination of rotational CT movements and locally constrained chromatin movements. PMID:21327076

  4. TU-C-BRD-01: Image Guided SBRT I: Multi-Modality 4D Imaging

    SciTech Connect

    Cai, J; Mageras, G; Pan, T

    2014-06-15

    Motion management is one of the critical technical challenges for radiation therapy. 4D imaging has been rapidly adopted as essential tool to assess organ motion associated with respiratory breathing. A variety of 4D imaging techniques have been developed and are currently under development based on different imaging modalities such as CT, MRI, PET, and CBCT. Each modality provides specific and complementary information about organ and tumor respiratory motion. Effective use of each different technique or combined use of different techniques can introduce a comprehensive management of tumor motion. Specifically, these techniques have afforded tremendous opportunities to better define and delineate tumor volumes, more accurately perform patient positioning, and effectively apply highly conformal therapy techniques such as IMRT and SBRT. Successful implementation requires good understanding of not only each technique, including unique features, limitations, artifacts, imaging acquisition and process, but also how to systematically apply the information obtained from different imaging modalities using proper tools such as deformable image registration. Furthermore, it is important to understand the differences in the effects of breathing variation between different imaging modalities. A comprehensive motion management strategy using multi-modality 4D imaging has shown promise in improving patient care, but at the same time faces significant challenges. This session will focuses on the current status and advances in imaging respiration-induced organ motion with different imaging modalities: 4D-CT, 4D-MRI, 4D-PET, and 4D-CBCT/DTS. Learning Objectives: Understand the need and role of multimodality 4D imaging in radiation therapy. Understand the underlying physics behind each 4D imaging technique. Recognize the advantages and limitations of each 4D imaging technique.

  5. GL4D: a GPU-based architecture for interactive 4D visualization.

    PubMed

    Chu, Alan; Fu, Chi-Wing; Hanson, Andrew J; Heng, Pheng-Ann

    2009-01-01

    This paper describes GL4D, an interactive system for visualizing 2-manifolds and 3-manifolds embedded in four Euclidean dimensions and illuminated by 4D light sources. It is a tetrahedron-based rendering pipeline that projects geometry into volume images, an exact parallel to the conventional triangle-based rendering pipeline for 3D graphics. Novel features include GPU-based algorithms for real-time 4D occlusion handling and transparency compositing; we thus enable a previously impossible level of quality and interactivity for exploring lit 4D objects. The 4D tetrahedrons are stored in GPU memory as vertex buffer objects, and the vertex shader is used to perform per-vertex 4D modelview transformations and 4D-to-3D projection. The geometry shader extension is utilized to slice the projected tetrahedrons and rasterize the slices into individual 2D layers of voxel fragments. Finally, the fragment shader performs per-voxel operations such as lighting and alpha blending with previously computed layers. We account for 4D voxel occlusion along the 4D-to-3D projection ray by supporting a multi-pass back-to-front fragment composition along the projection ray; to accomplish this, we exploit a new adaptation of the dual depth peeling technique to produce correct volume image data and to simultaneously render the resulting volume data using 3D transfer functions into the final 2D image. Previous CPU implementations of the rendering of 4D-embedded 3-manifolds could not perform either the 4D depth-buffered projection or manipulation of the volume-rendered image in real-time; in particular, the dual depth peeling algorithm is a novel GPU-based solution to the real-time 4D depth-buffering problem. GL4D is implemented as an integrated OpenGL-style API library, so that the underlying shader operations are as transparent as possible to the user.

  6. A randomized controlled trial on the efficacy of thoracic CT screening for lung cancer in non-smokers and smokers of <30 pack-years aged 50-64 years (JECS study): research design.

    PubMed

    Sagawa, Motoyasu; Nakayama, Tomio; Tanaka, Makoto; Sakuma, Tsutomu; Sobue, Tomotaka

    2012-12-01

    In order to assess the efficacy of lung cancer screening using low-dose thoracic computed tomography, compared with chest roentgenography, in people aged 50-64 years with a smoking history of <30 pack-years, a randomized controlled trial is being conducted in Japan. The screening methods are randomly assigned individually. The duration of this trial is 10 years. In the intervention arm, low-dose thoracic computed tomography is performed for each participant in the first and the sixth years. In the control arm, chest roentgenography is performed for each participant in the first year. The participants in both arms are also encouraged to receive routine lung cancer screening using chest roentgenography annually. The interpretation of radiological findings and the follow-up of undiagnosed nodules are to be carried out according to the guidelines published in Japan. The required sample size is calculated to be 17 500 subjects for each arm.

  7. Shadow-driven 4D haptic visualization.

    PubMed

    Zhang, Hui; Hanson, Andrew

    2007-01-01

    Just as we can work with two-dimensional floor plans to communicate 3D architectural design, we can exploit reduced-dimension shadows to manipulate the higher-dimensional objects generating the shadows. In particular, by taking advantage of physically reactive 3D shadow-space controllers, we can transform the task of interacting with 4D objects to a new level of physical reality. We begin with a teaching tool that uses 2D knot diagrams to manipulate the geometry of 3D mathematical knots via their projections; our unique 2D haptic interface allows the user to become familiar with sketching, editing, exploration, and manipulation of 3D knots rendered as projected imageson a 2D shadow space. By combining graphics and collision-sensing haptics, we can enhance the 2D shadow-driven editing protocol to successfully leverage 2D pen-and-paper or blackboard skills. Building on the reduced-dimension 2D editing tool for manipulating 3D shapes, we develop the natural analogy to produce a reduced-dimension 3D tool for manipulating 4D shapes. By physically modeling the correct properties of 4D surfaces, their bending forces, and their collisions in the 3D haptic controller interface, we can support full-featured physical exploration of 4D mathematical objects in a manner that is otherwise far beyond the experience accessible to human beings. As far as we are aware, this paper reports the first interactive system with force-feedback that provides "4D haptic visualization" permitting the user to model and interact with 4D cloth-like objects.

  8. Planning 4D intensity-modulated arc therapy for tumor tracking with a multileaf collimator

    NASA Astrophysics Data System (ADS)

    Niu, Ying; Betzel, Gregory T.; Yang, Xiaocheng; Gui, Minzhi; Parke, William C.; Yi, Byongyong; Yu, Cedric X.

    2017-02-01

    This study introduces a practical four-dimensional (4D) planning scheme of IMAT using 4D computed tomography (4D CT) for planning tumor tracking with dynamic multileaf beam collimation. We assume that patients can breathe regularly, i.e. the same way as during 4D CT with an unchanged period and amplitude, and that the start of 4D-IMAT delivery can be synchronized with a designated respiratory phase. Each control point of the IMAT-delivery process can be associated with an image set of 4D CT at a specified respiratory phase. Target is contoured at each respiratory phase without a motion-induced margin. A 3D-IMAT plan is first optimized on a reference-phase image set of 4D CT. Then, based on the projections of the planning target volume in the beam’s eye view at different respiratory phases, a 4D-IMAT plan is generated by transforming the segments of the optimized 3D plan by using a direct aperture deformation method. Compensation for both translational and deformable tumor motion is accomplished, and the smooth delivery of the transformed plan is ensured by forcing connectivity between adjacent angles (control points). It is envisioned that the resultant plans can be delivered accurately using the dose rate regulated tracking method which handles breathing irregularities (Yi et al 2008 Med. Phys. 35 3955–62).This planning process is straightforward and only adds a small step to current clinical 3D planning practice. Our 4D planning scheme was tested on three cases to evaluate dosimetric benefits. The created 4D-IMAT plans showed similar dose distributions as compared with the 3D-IMAT plans on a single static phase, indicating that our method is capable of eliminating the dosimetric effects of breathing induced target motion. Compared to the 3D-IMAT plans with large treatment margins encompassing respiratory motion, our 4D-IMAT plans reduced radiation doses to surrounding normal organs and tissues.

  9. IMRT treatment planning on 4D geometries for the era of dynamic MLC tracking.

    PubMed

    Suh, Yelin; Murray, Walter; Keall, Paul J

    2014-12-01

    score by 4-50% compared with 3D optimization. The 4D treatment plans had leaf sequences that varied from phase to phase to account for anatomic motion, but showed similar target dose distributions in each phase. The current method could in principle be generalized for use in offline replanning between fractions or for online 4D treatment planning based on 4D cone-beam CT images. Computation time remains a challenge.

  10. [Blunt thoracic injury].

    PubMed

    Miura, H; Taira, O; Hiraguri, S; Uchida, O; Hagiwara, M; Ikeda, T; Kato, H

    1998-06-01

    Of 161 patients with blunt thoracic injury, 135 were male (83.9%) and 26 were female. The most common cause of injury was traffic accidents (130 patients, 80.7%), followed by falls (22 patients), and crushing (7 patients). There were 46 third decade and 36 second decade patients. Thirty-two patients had single thoracic injury and the other had multiple organ injury. The most common associated injury was head injury (65 patients). Most traffic accidents involved motor cycle accident. Forty-four patients died, 32 within 24 hours, and 4 died to thoracic injury. These 4 patients were shock on arrival and died within 24 hours. The injury severity score, which was under 30 in 78.3% of patients, correlated to the mortality rate. Rib fracture was the most common thoracic injury in 96 patients followed by hemothorax in 91, pulmonary contusion in 79, and pneumothorax in 64. Most of the thoracic injuries were treated conservatively. Thoracotomy was performed in 6 patients. Other than one patient with rupture of the left pulmonary vein, 5 patients recovered. Continued bleeding at a rate of more than 200 ml/h from the chest drainage tube or no recovery from shock and large air leakage preventing re-expansion of the lung are indications for emergency thoracotomy. Thoracotomy should also be considered after conservative treatment in patients with continued air leakage or intrabronchial bleeding negatively affecting respiration. Indications for thoracotomy should be determined individually based on evaluating of vital sign.

  11. Comparison of {sup 18}F-Fluorothymidine and {sup 18}F-Fluorodeoxyglucose PET/CT in Delineating Gross Tumor Volume by Optimal Threshold in Patients With Squamous Cell Carcinoma of Thoracic Esophagus

    SciTech Connect

    Han Dali; Yu Jinming; Yu Yonghua; Zhang Guifang; Zhong Xiaojun; Lu Jie; Yin Yong; Fu Zheng; Mu Dianbin; Zhang Baijiang; He Wei; Huo Zhijun; Liu Xijun; Kong Lei; Zhao Shuqiang; Sun Xiangyu

    2010-03-15

    Purpose: To determine the optimal method of using {sup 18}F-fluorothymidine (FLT) positron emission tomography (PET)/computed tomography (CT) simulation to delineate the gross tumor volume (GTV) in esophageal squamous cell carcinoma verified by pathologic examination and compare the results with those using {sup 18}F-fluorodeoxyglucose (FDG) PET/CT. Methods and Materials: A total of 22 patients were enrolled and underwent both FLT and FDG PET/CT. The GTVs with biologic information were delineated using seven different methods in FLT PET/CT and three different methods in FDG PET/CT. The results were compared with the pathologic gross tumor length, and the optimal threshold was obtained. Next, we compared the simulation plans using the optimal threshold of FLT and FDG PET/CT. The radiation dose was prescribed as 60 Gy in 30 fractions with a precise radiotherapy technique. Results: The mean +- standard deviation pathologic gross tumor length was 4.94 +- 2.21 cm. On FLT PET/CT, the length of the standardized uptake value 1.4 was 4.91 +- 2.43 cm. On FDG PET/CT, the length of the standardized uptake value 2.5 was 5.10 +- 2.18 cm, both of which seemed more approximate to the pathologic gross tumor length. The differences in the bilateral lung volume receiving >=20 Gy, heart volume receiving >=40 Gy, and the maximal dose received by spinal cord between FLT and FDG were not significant. However, the values for mean lung dose, bilateral lung volume receiving >=5, >=10, >=30, >=40, and >=50 Gy, mean heart dose, and heart volume receiving >=30 Gy using FLT PET/CT-based planning were significant lower than those using FDG PET/CT. Conclusion: A standardized uptake value cutoff of 1.4 on FLT PET/CT and one of 2.5 on FDG PET/CT provided the closest estimation of GTV length. Finally, FLT PET/CT-based treatment planning provided potential benefits to the lungs and heart.

  12. 4D-Var Developement at GMAO

    NASA Technical Reports Server (NTRS)

    Pelc, Joanna S.; Todling, Ricardo; Akkraoui, Amal El

    2014-01-01

    The Global Modeling and Assimilation Offce (GMAO) is currently using an IAU-based 3D-Var data assimilation system. GMAO has been experimenting with a 3D-Var-hybrid version of its data assimilation system (DAS) for over a year now, which will soon become operational and it will rapidly progress toward a 4D-EnVar. Concurrently, the machinery to exercise traditional 4DVar is in place and it is desirable to have a comparison of the traditional 4D approach with the other available options, and evaluate their performance in the Goddard Earth Observing System (GEOS) DAS. This work will also explore the possibility for constructing a reduced order model (ROM) to make traditional 4D-Var computationally attractive for increasing model resolutions. Part of the research on ROM will be to search for a suitably acceptable space to carry on the corresponding reduction. This poster illustrates how the IAU-based 4D-Var assimilation compares with our currently used IAU-based 3D-Var.

  13. Thoracic arachnoid cyst resection.

    PubMed

    Deutsch, Harel

    2014-09-01

    Arachnoid cysts in the spinal cord may be asymptomatic. In some cases arachnoid cysts may exert mass effect on the thoracic spinal cord and lead to pain and myelopathy symptoms. Arachnoid cysts may be difficult to visualize on an MRI scan because the thin walled arachnoid may not be visible. Focal displacement of the thoracic spinal cord and effacement of the spinal cord with apparent widening of the cerebrospinal fluid space is seen. This video demonstrates surgical techniques to remove a dorsal arachnoid cyst causing spinal cord compression. The surgery involves a thoracic laminectomy. The dura is opened sharply with care taken not to open the arachnoid so that the cyst can be well visualized. The thickened arachnoid walls of the cyst are removed to alleviate the compression caused by the arachnoid cyst. The video can be found here: http://youtu.be/pgUrl9xvsD0.

  14. Clinical evaluation of 4D PET motion compensation strategies for treatment verification in ion beam therapy

    NASA Astrophysics Data System (ADS)

    Gianoli, Chiara; Kurz, Christopher; Riboldi, Marco; Bauer, Julia; Fontana, Giulia; Baroni, Guido; Debus, Jürgen; Parodi, Katia

    2016-06-01

    A clinical trial named PROMETHEUS is currently ongoing for inoperable hepatocellular carcinoma (HCC) at the Heidelberg Ion Beam Therapy Center (HIT, Germany). In this framework, 4D PET-CT datasets are acquired shortly after the therapeutic treatment to compare the irradiation induced PET image with a Monte Carlo PET prediction resulting from the simulation of treatment delivery. The extremely low count statistics of this measured PET image represents a major limitation of this technique, especially in presence of target motion. The purpose of the study is to investigate two different 4D PET motion compensation strategies towards the recovery of the whole count statistics for improved image quality of the 4D PET-CT datasets for PET-based treatment verification. The well-known 4D-MLEM reconstruction algorithm, embedding the motion compensation in the reconstruction process of 4D PET sinograms, was compared to a recently proposed pre-reconstruction motion compensation strategy, which operates in sinogram domain by applying the motion compensation to the 4D PET sinograms. With reference to phantom and patient datasets, advantages and drawbacks of the two 4D PET motion compensation strategies were identified. The 4D-MLEM algorithm was strongly affected by inverse inconsistency of the motion model but demonstrated the capability to mitigate the noise-break-up effects. Conversely, the pre-reconstruction warping showed less sensitivity to inverse inconsistency but also more noise in the reconstructed images. The comparison was performed by relying on quantification of PET activity and ion range difference, typically yielding similar results. The study demonstrated that treatment verification of moving targets could be accomplished by relying on the whole count statistics image quality, as obtained from the application of 4D PET motion compensation strategies. In particular, the pre-reconstruction warping was shown to represent a promising choice when combined with intra

  15. Clinical evaluation of 4D PET motion compensation strategies for treatment verification in ion beam therapy.

    PubMed

    Gianoli, Chiara; Kurz, Christopher; Riboldi, Marco; Bauer, Julia; Fontana, Giulia; Baroni, Guido; Debus, Jürgen; Parodi, Katia

    2016-06-07

    A clinical trial named PROMETHEUS is currently ongoing for inoperable hepatocellular carcinoma (HCC) at the Heidelberg Ion Beam Therapy Center (HIT, Germany). In this framework, 4D PET-CT datasets are acquired shortly after the therapeutic treatment to compare the irradiation induced PET image with a Monte Carlo PET prediction resulting from the simulation of treatment delivery. The extremely low count statistics of this measured PET image represents a major limitation of this technique, especially in presence of target motion. The purpose of the study is to investigate two different 4D PET motion compensation strategies towards the recovery of the whole count statistics for improved image quality of the 4D PET-CT datasets for PET-based treatment verification. The well-known 4D-MLEM reconstruction algorithm, embedding the motion compensation in the reconstruction process of 4D PET sinograms, was compared to a recently proposed pre-reconstruction motion compensation strategy, which operates in sinogram domain by applying the motion compensation to the 4D PET sinograms. With reference to phantom and patient datasets, advantages and drawbacks of the two 4D PET motion compensation strategies were identified. The 4D-MLEM algorithm was strongly affected by inverse inconsistency of the motion model but demonstrated the capability to mitigate the noise-break-up effects. Conversely, the pre-reconstruction warping showed less sensitivity to inverse inconsistency but also more noise in the reconstructed images. The comparison was performed by relying on quantification of PET activity and ion range difference, typically yielding similar results. The study demonstrated that treatment verification of moving targets could be accomplished by relying on the whole count statistics image quality, as obtained from the application of 4D PET motion compensation strategies. In particular, the pre-reconstruction warping was shown to represent a promising choice when combined with intra

  16. Thoracic ectopia cordis.

    PubMed

    Shad, Jimmy; Budhwani, Keshav; Biswas, Rakesh

    2012-09-30

    Ectopia cordis is defined as complete or partial displacement of the heart outside the thoracic cavity. It is a rare congenital defect in fusion of the anterior chest wall resulting in extra thoracic location of the heart. Its estimated prevalence is 5.5-7.9 per million live births. The authors had one such case of a 15-h-old full-term male neonate weighing 2.25 kg with an externally visible, beating heart over the chest wall. The neonate had difficulty in respiration with peripheral cyanosis. Patient died of cardiorespiratory arrest before any surgical intervention could be undertaken inspite of best possible resuscitative measures.

  17. Thoracic ectopia cordis

    PubMed Central

    Shad, Jimmy; Budhwani, Keshav; Biswas, Rakesh

    2012-01-01

    Ectopia cordis is defined as complete or partial displacement of the heart outside the thoracic cavity. It is a rare congenital defect in fusion of the anterior chest wall resulting in extra thoracic location of the heart. Its estimated prevalence is 5.5–7.9 per million live births. The authors had one such case of a 15-h-old full-term male neonate weighing 2.25 kg with an externally visible, beating heart over the chest wall. The neonate had difficulty in respiration with peripheral cyanosis. Patient died of cardiorespiratory arrest before any surgical intervention could be undertaken inspite of best possible resuscitative measures. PMID:23035158

  18. Complete thoracic ectopia cordis.

    PubMed

    Alphonso, N; Venugopal, P S; Deshpande, R; Anderson, D

    2003-03-01

    Thoracic ectopia cordis is a rare congenital defect with very few reported survivors after surgical correction. We report a case of complete thoracic ectopia cordis with double outlet right ventricle. The diagnosis was established antenatally and a repair was undertaken soon after birth. The child remained stable and was extubated on the fifth post-operative day. Forty-eight hours later the child succumbed to an unexplained respiratory arrest. Also presented is a review of the different surgical strategies for this unusual condition.

  19. Image quality of mixed convolution kernel in thoracic computed tomography.

    PubMed

    Neubauer, Jakob; Spira, Eva Maria; Strube, Juliane; Langer, Mathias; Voss, Christian; Kotter, Elmar

    2016-11-01

    The mixed convolution kernel alters his properties geographically according to the depicted organ structure, especially for the lung. Therefore, we compared the image quality of the mixed convolution kernel to standard soft and hard kernel reconstructions for different organ structures in thoracic computed tomography (CT) images.Our Ethics Committee approved this prospective study. In total, 31 patients who underwent contrast-enhanced thoracic CT studies were included after informed consent. Axial reconstructions were performed with hard, soft, and mixed convolution kernel. Three independent and blinded observers rated the image quality according to the European Guidelines for Quality Criteria of Thoracic CT for 13 organ structures. The observers rated the depiction of the structures in all reconstructions on a 5-point Likert scale. Statistical analysis was performed with the Friedman Test and post hoc analysis with the Wilcoxon rank-sum test.Compared to the soft convolution kernel, the mixed convolution kernel was rated with a higher image quality for lung parenchyma, segmental bronchi, and the border between the pleura and the thoracic wall (P < 0.03). Compared to the hard convolution kernel, the mixed convolution kernel was rated with a higher image quality for aorta, anterior mediastinal structures, paratracheal soft tissue, hilar lymph nodes, esophagus, pleuromediastinal border, large and medium sized pulmonary vessels and abdomen (P < 0.004) but a lower image quality for trachea, segmental bronchi, lung parenchyma, and skeleton (P < 0.001).The mixed convolution kernel cannot fully substitute the standard CT reconstructions. Hard and soft convolution kernel reconstructions still seem to be mandatory for thoracic CT.

  20. Ultrasound-guided mesenteric lymph node iohexol injection for thoracic duct computed tomographic lymphography in cats.

    PubMed

    Kim, Mieun; Lee, Hyeyeon; Lee, Namsoon; Choi, Mihyeon; Kim, Junyoung; Chang, Dongwoo; Choi, Mincheol; Yoon, Junghee

    2011-01-01

    Computed tomographic (CT) lymphography was performed in cats using percutaneous ultrasound-guided injection of contrast medium into a mesenteric lymph node. The thoracic duct and its branches were clearly delineated in CT images of seven cats studied. The thoracic duct was characterized by anatomic variation and appeared as single or multiple branches. The thoracic duct and the cisterna chyli were identified along the ventral or left ventral aspect of the vertebrae from the level of the cranial lumbar to the caudal cervical vertebrae. The thoracic duct was identified in the central caudal mediastinum, deviated to the left in the cranial mediastinum, and finally moved toward the venous system. Small volumes of extranodal contrast medium leakage were identified in all cats. After injection, the mesenteric lymph nodes were cytologically normal. Ultrasound-guided CT lymphography via percutaneous mesenteric lymph node injection appears safe and effective in cats.

  1. SU-E-J-06: A Feasibility Study On Clinical Implementation of 4D-CBCT in Lung Cancer Treatment

    SciTech Connect

    Hu, Y; Stanford, J; Duggar, W; Ruan, C; He, R; Yang, C

    2014-06-01

    Purpose: Four-dimensional cone-beam CT (4D-CBCT) is a novel imaging technique to setup patients with pulmonary lesions in radiation therapy. This paper is to perform a feasibility study on the implementation of 4D-CBCT as image guidance for (1) SBRT and (2) Low Modulation (Low-Mod) IMRT in lung cancer treatment. Methods: Image artifacts and observers variability are evaluated by analyzing the 4D-CT QA phantom and patient 4D image data. There are two 4D-CBCT image artifacts: (1) Spatial artifact caused by the patient irregular breathing pattern will generate blurring and anatomy gap/overlap; (2) Cone beam scattering and hardening artifact will affect the image spatial and contrast resolution. The couch shift varies between 1mm to 3mm from different observers during the 4D-CBCT registration. Breath training is highly recommended to improve the respiratory regularity during CT simulation and treatment, especially for SBRT. Elekta XVI 4.5 Symmetry protocol is adopted in the patient 4DCBCT scanning and intensity-based registration. Physician adjustments on the auto-registration are involved prior to the treatment. Physician peer review on 4D-CBCT image acquisition and registration is also recommended to reduce the inter-observer variability. The average 4D-CT in reference volume coordinates is exported to MIM Vista 5.6.2 to manually fuse to the planning CT for further evaluation. Results: (1) SBRT: 4DCBCT is performed in dry-run and in each treatment fraction. Image registration and couch shift are reviewed by another physician on the 1st fraction before the treatment starts. (2) Low-Mod IMRT: 4D-CBCT is performed and peer reviewed on weekly basis. Conclusion: 4D-CBCT in SBRT dry-run can discover the ITV discrepancies caused by the low quality 4D-CT simulation. 4D-CBCT during SBRT and Low-Mod IMRT treatment provides physicians more confidence to target lung tumor and capability to evaluate inter-fractional ITV changes. More advanced 4D-CBCT scan protocol and

  2. Interactive animation of 4D performance capture.

    PubMed

    Casas, Dan; Tejera, Margara; Guillemaut, Jean-Yves; Hilton, Adrian

    2013-05-01

    A 4D parametric motion graph representation is presented for interactive animation from actor performance capture in a multiple camera studio. The representation is based on a 4D model database of temporally aligned mesh sequence reconstructions for multiple motions. High-level movement controls such as speed and direction are achieved by blending multiple mesh sequences of related motions. A real-time mesh sequence blending approach is introduced, which combines the realistic deformation of previous nonlinear solutions with efficient online computation. Transitions between different parametric motion spaces are evaluated in real time based on surface shape and motion similarity. Four-dimensional parametric motion graphs allow real-time interactive character animation while preserving the natural dynamics of the captured performance.

  3. Respiratory gating and 4-D tomotherapy

    SciTech Connect

    Zhang Tiezhi

    2004-12-01

    Helical tomotherapy is a new intensity-modulated radiotherapy (IMRT) delivery process developed at the University of Wisconsin and TomoTherapy Inc. Tomotherapy may be of advantage in lung cancer treatment due to its rotational delivery mode. As with conventional IMRT delivery, however, intrafraction respiratory motion during a tomotherapy treatment causes unnecessary radiation to the healthy tissue. Possible solutions to these problems associated with intrafraction motion have been studied in this thesis. A spirometer is useful for monitoring breathing because of its direct correlation with lung volume changes. However, its inherent drift prevents its application in long-term breathing monitoring. With calibration and stabilization algorithms, a spirometer is able to provide accurate, long-term lung volume change measurements. Such a spirometer system is most suited for deep inspiration breath-hold (DIBH) treatments. An improved laser-spirometer combined system has also been developed for target tracking in 4-D treatment. Spirometer signals are used to calibrate the displacement measurements into lung volume changes, thereby eliminating scaling errors from daily setup variations. The laser displacement signals may also be used to correct spirometer drifts during operation. A new 4-D treatment technique has been developed to account for intrafraction motion in treatment planning. The patient's breathing and the beam delivery are synchronized, and the target motion/deformation is incorporated into treatment plan optimization. Results show that this new 4D treatment technique significantly reduces motion effects and provides improved patient tolerance.

  4. Thoracic wall reconstruction using ultrasound images to model/bend the thoracic prosthesis for correction of pectus excavatum

    NASA Astrophysics Data System (ADS)

    Fonseca, João Gomes; Moreira, Antonio H. J.; Rodrigues, Pedro L.; Fonseca, Jaime C.; Pinho, A. C. M.; Correia-Pinto, Jorge; Rodrigues, Nuno F.; Vilaça, João L.

    2012-03-01

    Pectus excavatum is the most common congenital deformity of the anterior thoracic wall. The surgical correction of such deformity, using Nuss procedure, consists in the placement of a personalized convex prosthesis into sub-sternal position to correct the deformity. The aim of this work is the CT-scan substitution by ultrasound imaging for the pre-operative diagnosis and pre-modeling of the prosthesis, in order to avoid patient radiation exposure. To accomplish this, ultrasound images are acquired along an axial plane, followed by a rigid registration method to obtain the spatial transformation between subsequent images. These images are overlapped to reconstruct an axial plane equivalent to a CT-slice. A phantom was used to conduct preliminary experiments and the achieved results were compared with the corresponding CT-data, showing that the proposed methodology can be capable to create a valid approximation of the anterior thoracic wall, which can be used to model/bend the prosthesis.

  5. White Matter and Gray Matter Segmentation in 4D Computed Tomography.

    PubMed

    Manniesing, Rashindra; Oei, Marcel T H; Oostveen, Luuk J; Melendez, Jaime; Smit, Ewoud J; Platel, Bram; Sánchez, Clara I; Meijer, Frederick J A; Prokop, Mathias; van Ginneken, Bram

    2017-12-01

    Modern Computed Tomography (CT) scanners are capable of acquiring contrast dynamics of the whole brain, adding functional to anatomical information. Soft tissue segmentation is important for subsequent applications such as tissue dependent perfusion analysis and automated detection and quantification of cerebral pathology. In this work a method is presented to automatically segment white matter (WM) and gray matter (GM) in contrast- enhanced 4D CT images of the brain. The method starts with intracranial segmentation via atlas registration, followed by a refinement using a geodesic active contour with dominating advection term steered by image gradient information, from a 3D temporal average image optimally weighted according to the exposures of the individual time points of the 4D CT acquisition. Next, three groups of voxel features are extracted: intensity, contextual, and temporal. These are used to segment WM and GM with a support vector machine. Performance was assessed using cross validation in a leave-one-patient-out manner on 22 patients. Dice coefficients were 0.81 ± 0.04 and 0.79 ± 0.05, 95% Hausdorff distances were 3.86 ± 1.43 and 3.07 ± 1.72 mm, for WM and GM, respectively. Thus, WM and GM segmentation is feasible in 4D CT with good accuracy.

  6. Active origami by 4D printing

    NASA Astrophysics Data System (ADS)

    Ge, Qi; Dunn, Conner K.; Qi, H. Jerry; Dunn, Martin L.

    2014-09-01

    Recent advances in three dimensional (3D) printing technology that allow multiple materials to be printed within each layer enable the creation of materials and components with precisely controlled heterogeneous microstructures. In addition, active materials, such as shape memory polymers, can be printed to create an active microstructure within a solid. These active materials can subsequently be activated in a controlled manner to change the shape or configuration of the solid in response to an environmental stimulus. This has been termed 4D printing, with the 4th dimension being the time-dependent shape change after the printing. In this paper, we advance the 4D printing concept to the design and fabrication of active origami, where a flat sheet automatically folds into a complicated 3D component. Here we print active composites with shape memory polymer fibers precisely printed in an elastomeric matrix and use them as intelligent active hinges to enable origami folding patterns. We develop a theoretical model to provide guidance in selecting design parameters such as fiber dimensions, hinge length, and programming strains and temperature. Using the model, we design and fabricate several active origami components that assemble from flat polymer sheets, including a box, a pyramid, and two origami airplanes. In addition, we directly print a 3D box with active composite hinges and program it to assume a temporary flat shape that subsequently recovers to the 3D box shape on demand.

  7. 4d Spectra from BPS Quiver Dualities

    NASA Astrophysics Data System (ADS)

    Espahbodi, Sam

    We attack the question of BPS occupancy in a wide class of 4d N = 2 quantum field theories. We first review the Seiberg-Witten approach to finding the low energy Wilsonian effective action actions of such theories. In particular, we analyze the case of Gaiotto theories, which provide a large number of non-trivial examples in a unified framework. We then turn to understanding the massive BPS spectrum of such theories, and in particular their relation to BPS quivers. We present a purely 4d characterization of BPS quivers, and explain how a quiver's representation theory encodes the solution to the BPS occupancy problem. Next, we derive a so called mutation method, based on exploiting quiver dualities, to solve the quiver's representation theory. This method makes previously intractable calculations nearly trivial in many examples. As a particular highlight, we apply our methods to understand strongly coupled chambers in ADE SYM gauge theories with matter. Following this, we turn to the general story of quivers for theories of the Gaiotto class. We present a geometric approach to attaining quivers for the rank 2 theories, leading to a very elegant solution which includes a specification of quiver superpotentials. Finally, we solve these theories by an unrelated method based on gauging flavor symmetries in their various dual weakly coupled Lagrangian descriptions. After seeing that this method agrees in the rank 2 case, we will apply our new approach to the case of rank n.

  8. [Surgery for thoracic tuberculosis].

    PubMed

    Kilani, T; Boudaya, M S; Zribi, H; Ouerghi, S; Marghli, A; Mestiri, T; Mezni, F

    2015-01-01

    Tuberculosis is mainly a medical disease. Surgery has been the unique therapeutic tool for a long time before the advent of specific antituberculous drugs, and the role of surgery was then confined to the treatment of the sequelae of tuberculosis and their complications. The resurgence of tuberculosis and the emergence of multidrug-resistant TB combined to immunosuppressed patients represent a new challenge for tuberculosis surgery. Surgery may be indicated for a diagnostic purpose in patients with pulmonary, pleural, mediastinal or thoracic wall involvement, or with a therapeutic purpose (drainage, resection, residual cavity obliteration). Modern imaging techniques and the advent of video-assisted thoracic surgery allowed a new approach of this pathology; the majority of diagnostic interventions and selected cases requiring lung resection can be performed through a mini-invasive approach. Patients proposed for aggressive surgery may be treated with the best results thanks to a good evaluation of the thoracic lesions, of the patients' nutritional, infectious and general status combined with a good coordination between the specialized medical team for an optimal preparation to surgery.

  9. TU-EF-304-02: 4D Optimized Treatment Planning for Actively Scanned Proton Therapy Delivered to Moving Target Volume

    SciTech Connect

    Bernatowicz, K; Zhang, Y; Weber, D; Lomax, A

    2015-06-15

    Purpose: To develop a 4D treatment optimization approach for Pencil Beam Scanned (PBS) proton therapy that includes breathing variability. Method: PBS proton therapy delivers a pattern of proton pencil beams (PBs), distributed to cover the target volume and optimized such as to achieve a homogenous dose distribution across the target. In this work, this optimization step has been enhanced to include advanced 4D dose calculations of liver tumors based on motion extracted from either 4D-CT (representing a single and averaged respiratory cycle) or 4D-CT(MRI) (including breathing variability). The 4D dose calculation is performed per PB on deforming dose grid, and according to the timestamp of each PB, a displacement due to patient’s motion and a change in radiological depth.Three different treatment fields have been optimized in 3D on the end-exhale phase of a 4D-CT liver data set (3D-opt) and then in 4D using the motion extracted from either 4D-CT or 4D-CT(MRI) using deformable image registration. All plans were calculated directly on the PTV without the use of an ITV. The delivery characteristics of the PSI Gantry 2 have been assumed for all calculations. Results: Dose inhomogeneities (D5-D95) in the CTV for the 3D optimized plans recalculated under conditions of variable motion were increased by on average 19.8% compared to the static case. These differences could be reduced by 4D-CT based 4D optimization to 10.5% and by 4D-CT(MRI) based optimization to only 2.3% of the static value. Liver V25 increased by less than 1% using 4D optimization. Conclusion: 4D optimized PBS treatment plans taking into account breathing variability provide for significantly improved robustness against motion and motion variability than those based on 4D-CT alone, and may negate the need of motion specific target expansions. Swiss National Fund Grant (320030-1493942-1)

  10. Left ventricular assist device malposition interrogated by 4-D cine computed tomography.

    PubMed

    Bolen, Michael A; Popovic, Zoran B; Gonzalez-Stawinski, Gonzalo; Schoenhagen, Paul

    2011-01-01

    67-year-old female with left ventricular assist device (LVAD) presented with recurrent low-flow alarms. No clear etiology could be determined by history, or evaluation with radiograph and echocardiogram. Computed tomographic (CT) imaging with 3-D and 4-D assessment identified the abnormality as steep angulation of the inflow cannula and partial obstruction by the adjacent anterior wall, likely in part caused by recovered left ventricular function and reverse remodeling. Improved left ventricle size and function was correlated by semi-automated analysis of CT data, which also indicated mild right ventricle dilation and systolic dysfunction. LVAD explantation was performed, and has been well tolerated by the patient. Echocardiography remains the primary imaging modality to assess patients post LVAD placement, but in this instance CT provided valuable information to identify the abnormality and help direct patient management. CT assessment in patients with LVAD additionally provides valuable information prior to redo sternotomy for pump explantation, revision, or transplantation.

  11. Nonintubated anesthesia for thoracic surgery

    PubMed Central

    Wang, Bei

    2014-01-01

    Nonintubated thoracic surgery has been used in procedures including pleura, lungs and mediastinum. Appropriate anesthesia techniques with or without sedation allow thoracic surgery patients to avoid the potential risks of intubated general anesthesia, particularly for the high-risk patients. However, nonintubated anesthesia for thoracic surgery has some benefits as well as problems. In this review, the background, indication, perioperative anesthetic consideration and management, and advantages and disadvantages are discussed and summarized. PMID:25589994

  12. Soft Route to 4D Tomography

    NASA Astrophysics Data System (ADS)

    Taillandier-Thomas, Thibault; Roux, Stéphane; Hild, François

    2016-07-01

    Based on the assumption that the time evolution of a sample observed by computed tomography requires many less parameters than the definition of the microstructure itself, it is proposed to reconstruct these changes based on the initial state (using computed tomography) and very few radiographs acquired at fixed intervals of time. This Letter presents a proof of concept that for a fatigue cracked sample its kinematics can be tracked from no more than two radiographs in situations where a complete 3D view would require several hundreds of radiographs. This 2 order of magnitude gain opens the way to a "computed" 4D tomography, which complements the recent progress achieved in fast or ultrafast computed tomography, which is based on beam brightness, detector sensitivity, and signal acquisition technologies.

  13. Image segmentation and registration algorithm to collect thoracic skeleton semilandmarks for characterization of age and sex-based thoracic morphology variation.

    PubMed

    Weaver, Ashley A; Nguyen, Callistus M; Schoell, Samantha L; Maldjian, Joseph A; Stitzel, Joel D

    2015-12-01

    Thoracic anthropometry variations with age and sex have been reported and likely relate to thoracic injury risk and outcome. The objective of this study was to collect a large volume of homologous semilandmark data from the thoracic skeleton for the purpose of quantifying thoracic morphology variations for males and females of ages 0-100 years. A semi-automated image segmentation and registration algorithm was applied to collect homologous thoracic skeleton semilandmarks from 343 normal computed tomography (CT) scans. Rigid, affine, and symmetric diffeomorphic transformations were used to register semilandmarks from an atlas to homologous locations in the subject-specific coordinate system. Homologous semilandmarks were successfully collected from 92% (7077) of the ribs and 100% (187) of the sternums included in the study. Between 2700 and 11,000 semilandmarks were collected from each rib and sternum and over 55 million total semilandmarks were collected from all subjects. The extensive landmark data collected more fully characterizes thoracic skeleton morphology across ages and sexes. Characterization of thoracic morphology with age and sex may help explain variations in thoracic injury risk and has important implications for vulnerable populations such as pediatrics and the elderly.

  14. Controlled Source 4D Seismic Imaging

    NASA Astrophysics Data System (ADS)

    Luo, Y.; Morency, C.; Tromp, J.

    2009-12-01

    Earth's material properties may change after significant tectonic events, e.g., volcanic eruptions, earthquake ruptures, landslides, and hydrocarbon migration. While many studies focus on how to interpret observations in terms of changes in wavespeeds and attenuation, the oil industry is more interested in how we can identify and locate such temporal changes using seismic waves generated by controlled sources. 4D seismic analysis is indeed an important tool to monitor fluid movement in hydrocarbon reservoirs during production, improving fields management. Classic 4D seismic imaging involves comparing images obtained from two subsequent seismic surveys. Differences between the two images tell us where temporal changes occurred. However, when the temporal changes are small, it may be quite hard to reliably identify and characterize the differences between the two images. We propose to back-project residual seismograms between two subsequent surveys using adjoint methods, which results in images highlighting temporal changes. We use the SEG/EAGE salt dome model to illustrate our approach. In two subsequent surveys, the wavespeeds and density within a target region are changed, mimicking possible fluid migration. Due to changes in material properties induced by fluid migration, seismograms recorded in the two surveys differ. By back propagating these residuals, the adjoint images identify the location of the affected region. An important issue involves the nature of model. For instance, are we characterizing only changes in wavespeed, or do we also consider density and attenuation? How many model parameters characterize the model, e.g., is our model isotropic or anisotropic? Is acoustic wave propagation accurate enough or do we need to consider elastic or poroelastic effects? We will investigate how imaging strategies based upon acoustic, elastic and poroelastic simulations affect our imaging capabilities.

  15. SU-E-T-464: Implementation and Validation of 4D Acuros XB Dose Calculations

    SciTech Connect

    Thomas, S; Yuen, C; Huang, V; Milette, M; Teke, T

    2015-06-15

    Purpose: In this abstract we implement and validate a 4D VMAT Acuros XB dose calculation using Gafchromic film. Special attention is paid to the physical material assignment in the CT dataset and to reported dose to water and dose to medium. Methods: A QUASAR phantom with a 3 cm sinusoidal tumor motion and 5 second period was scanned using 4D computed tomography. A CT was also obtained of the static QUASAR phantom with the tumor at the central position. A VMAT plan was created on the average CT dataset and was delivered on a Varian TrueBeam linear accelerator. The trajectory log file from this treatment was acquired and used to create 10 VMAT subplans (one for each portion of the breathing cycle). Motion for each subplan was simulated by moving the beam isocentre in the superior/inferior direction in the Treatment Planning System on the static CT scan. The 10 plans were calculated (both dose to medium and dose to water) and summed for 1) the original HU values from the static CT scan and 2) the correct physical material assignment in the CT dataset. To acquire a breathing phase synchronized film measurements the trajectory log was used to create a VMAT delivery plan which includes dynamic couch motion using the Developer Mode. Three different treatment start phases were investigated (mid inhalation, full inhalation and full exhalation). Results: For each scenario the coronal dose distributions were measured using Gafchromic film and compared to the corresponding calculation with Film QA Pro Software using a Gamma test with a 3%/3mm distance to agreement criteria. Good agreement was found between calculation and measurement. No statistically significant difference in agreement was found between calculations to original HU values vs calculations to over-written (material-assigned) HU values. Conclusion: The investigated 4D dose calculation method agrees well with measurement.

  16. Flexion myelopathy of the thoracic spine. Case report.

    PubMed

    Fujibayashi, Shunsuke; Neo, Masashi; Nakamura, Takashi

    2007-01-01

    The authors report a rare case of surgically treated symptomatic thoracic kyphosis caused by dynamic compression in an elderly man. Myelopathy due to thoracic kyphosis has been reported in patients with congenital kyphosis, Scheuermann dorsal kyphosis, and Cushing disease, but to the authors' knowledge this is the first report of dynamic kyphosis in an elderly person. This otherwise healthy 84-year-old man presented with a 2-year history of progressive difficulty in walking and bilateral leg dysesthesia. Despite several cervical and lumbar surgeries, his symptoms gradually worsened. A radiological examination revealed severe thoracic kyphosis, with a lateral Cobb angle of 59 degrees from T-2 to T-12. On a dynamic computed tomography (CT) myelogram, severe thoracic spinal cord draping and stretching on flexion was demonstrated. On extension, however, imaging studies failed to show draping or stretching. Posterior corrective fusion was performed with instrumentation from T-2 to T-9. Postoperative CT myelography demonstrated no significant spinal cord compression with restoration of the cerebrospinal fluid space anterior to the spinal cord, and the successful correction of the kyphosis to 44 degrees. The patient's neurological sequelae gradually resolved throughout 6 months of follow up.

  17. Opening the Black Box of ICT4D: Advancing Our Understanding of ICT4D Partnerships

    ERIC Educational Resources Information Center

    Park, Sung Jin

    2013-01-01

    The term, Information and Communication Technologies for Development (ICT4D), pertains to programs or projects that strategically use ICTs (e.g. mobile phones, computers, and the internet) as a means toward the socio-economic betterment for the poor in developing contexts. Gaining the political and financial support of the international community…

  18. Radiolucent 4D Ultrasound Imaging: System Design and Application to Radiotherapy Guidance.

    PubMed

    Schlosser, Jeffrey; Hristov, Dimitre

    2016-04-27

    Four-dimensional (4D) ultrasound (US) is an attractive modality for image guidance due to its real-time, non-ionizing, volumetric imaging capability with high soft tissue contrast. However, existing 4D US imaging systems contain large volumes of metal which interfere with diagnostic and therapeutic ionizing radiation in procedures such as CT imaging and radiation therapy. This study aimed to design and characterize a novel 4D Radiolucent Remotely-Actuated UltraSound Scanning (RRUSS) device that overcomes this limitation. In a phantom, we evaluated the imaging performance of the RRUSS device including frame rate, resolution, spatial integrity, and motion tracking accuracy. To evaluate compatibility with radiation therapy workflow, we evaluated device-induced CT imaging artifacts, US tracking performance during beam delivery, and device compatibility with commercial radiotherapy planning software. The RRUSS device produced 4D volumes at 0.1-3.0 Hz with 60⁰ lateral field of view (FOV), 50⁰ maximum elevational FOV, and 200 mm maximum depth. Imaging resolution (-3 dB point spread width) was 1.2-7.9 mm at depths up to 100 mm and motion tracking accuracy was ≤0.3±0.5 mm. No significant effect of the RRUSS device on CT image integrity was found, and RRUSS device performance was not affected by radiotherapy beam exposure. Agreement within ±3.0% / 2.0 mm was achieved between computed and measured radiotherapy dose delivered directly through the RRUSS device at 6 MV and 15 MV. In-vivo liver, kidney, and prostate images were successfully acquired. Our investigations suggest that a RRUSS device can offer non-interfering 4D guidance for radiation therapy and other diagnostic and therapeutic procedures.

  19. Radiolucent 4D Ultrasound Imaging: System Design and Application to Radiotherapy Guidance.

    PubMed

    Schlosser, Jeffrey; Hristov, Dimitre

    2016-10-01

    Four-dimensional (4D) ultrasound (US) is an attractive modality for image guidance due to its real-time, non-ionizing, volumetric imaging capability with high soft tissue contrast. However, existing 4D US imaging systems contain large volumes of metal which interfere with diagnostic and therapeutic ionizing radiation in procedures such as CT imaging and radiation therapy. This study aimed to design and characterize a novel 4D Radiolucent Remotely-Actuated UltraSound Scanning (RRUSS) device that overcomes this limitation. In a phantom, we evaluated the imaging performance of the RRUSS device including frame rate, resolution, spatial integrity, and motion tracking accuracy. To evaluate compatibility with radiation therapy workflow, we evaluated device-induced CT imaging artifacts, US tracking performance during beam delivery, and device compatibility with commercial radiotherapy planning software. The RRUSS device produced 4D volumes at 0.1-3.0 Hz with 60° lateral field of view (FOV), 50° maximum elevational FOV, and 200 mm maximum depth. Imaging resolution (-3 dB point spread width) was 1.2-7.9 mm at depths up to 100 mm and motion tracking accuracy was ≤ 0.3±0.5 mm. No significant effect of the RRUSS device on CT image integrity was found, and RRUSS device performance was not affected by radiotherapy beam exposure. Agreement within ±3.0% / 2.0 mm was achieved between computed and measured radiotherapy dose delivered directly through the RRUSS device at 6 MV and 15 MV. In vivo liver, kidney, and prostate images were successfully acquired. Our investigations suggest that a RRUSS device can offer non-interfering 4D guidance for radiation therapy and other diagnostic and therapeutic procedures.

  20. Towards respiration management in radiation treatment of lung tumors: transferring regions of interest from planning CT to kilovoltage X-ray images.

    PubMed

    Ataer-Cansizoglu, Esra; Bas, Erhan; Yousuf, M; You, Sheng; D'Souza, Warren D; Erdogmus, Deniz

    2010-01-01

    Tracking of lung tumors is imperative for improved radiotherapy treatment. However, the motion of the thoracic organs makes it a complicated task. 4D CT images acquired prior to treatment provide valuable information regarding the motion of organs and tumor, since it is manually annotated. In order to track tumors using treatment-day X-ray images (kV images), we need to find the correspondence with CT images so that projection of tumor region of interest will provide a good estimate about the position of the tumor on the X-ray image. In this study, we propose a method to estimate the alignment and respiration phase corresponding to X-ray images using 4D CT data. Our approach generates Digitally Reconstructed Radiographs (DRRs) using bilateral filter smoothing and computes rigid registration with kV images since the position and orientation of patient might differ between CT and treatment-day image acquisition processes. Instead of using landmark points, our registration method makes use of Kernel Density Estimation over the edges that are not affected much by respiration. To estimate the phase of X-ray, we apply template matching techniques between the lung regions of X-ray and registered DRRs. Our approach gives accurate results for rigid registration and provides a starting point to track tumors using the X-ray images during the treatment.

  1. A rare case of ectopic thoracic kidney and spleen.

    PubMed

    Krishnan, Babu; Lakshminarayanan, P; Sudhakar, M K; Vishwanathan, K N

    2011-07-01

    A 23-year-old male presented with fever of 5 days duration. His peripheral smear was positive for Plasmodium vivax. He was treated for malaria and responded. During investigation with USG it was found that he had absent left kidney. An abdominal contrast enhanced CT scan revealed ectopic kidney and spleen in the left hemithorax. This was a rare case of ectopic thoracic kidney and spleen.

  2. A design of a DICOM-RT-based tool box for nonrigid 4D dose calculation.

    PubMed

    Wong, Victy Y W; Baker, Colin R; Leung, T W; Tung, Stewart Y

    2016-03-08

    The study was aimed to introduce a design of a DICOM-RT-based tool box to facilitate 4D dose calculation based on deformable voxel-dose registration. The computational structure and the calculation algorithm of the tool box were explicitly discussed in the study. The tool box was written in MATLAB in conjunction with CERR. It consists of five main functions which allow a) importation of DICOM-RT-based 3D dose plan, b) deformable image registration, c) tracking voxel doses along breathing cycle, d) presentation of temporal dose distribution at different time phase, and e) derivation of 4D dose. The efficacy of using the tool box for clinical application had been verified with nine clinical cases on retrospective-study basis. The logistic and the robustness of the tool box were tested with 27 applications and the results were shown successful with no computational errors encountered. In the study, the accumulated dose coverage as a function of planning CT taken at end-inhale, end-exhale, and mean tumor position were assessed. The results indicated that the majority of the cases (67%) achieved maximum target coverage, while the planning CT was taken at the temporal mean tumor position and 56% at the end-exhale position. The comparable results to the literature imply that the studied tool box can be reliable for 4D dose calculation. The authors suggest that, with proper application, 4D dose calculation using deformable registration can provide better dose evaluation for treatment with moving target.

  3. Spatiotemporal directional analysis of 4D echocardiography

    NASA Astrophysics Data System (ADS)

    Angelini-Casadevall, Elsa D.; Laine, Andrew F.; Takuma, Shin; Homma, Shunichi

    2000-12-01

    Speckle noise corrupts ultrasonic data by introducing sharp changes in an echocardiographic image intensity profile, while attenuation alters the intensity of equally significant cardiac structures. These properties introduce inhomogeneity in the spatial domain and suggests that measures based on phase information rather than intensity are more appropriate for denoising and cardiac border detection. The present analysis method relies on the expansion of temporal ultrasonic volume data on complex exponential wavelet-like basis functions called Brushlets. These basis functions decompose a signal into distinct patterns of oriented textures. Projected coefficients are associated with distinct 'brush strokes' of a particular size and orientation. 4D overcomplete brushlet analysis is applied to temporal echocardiographic values. We show that adding the time dimension in the analysis dramatically improves the quality and robustness of the method without adding complexity in the design of a segmentation tool. We have investigated mathematical and empirical methods for identifying the most 'efficient' brush stroke sizes and orientations for decomposition and reconstruction on both phantom and clinical data. In order to determine the 'best tiling' or equivalently, the 'best brushlet basis', we use an entorpy-based information cost metric function. Quantitative validation and clinical applications of this new spatio-temporal analysis tool are reported for balloon phantoms and clinical data sets.

  4. Thoracic spine x-ray

    MedlinePlus

    Vertebral radiography; X-ray - spine; Thoracic x-ray; Spine x-ray; Thoracic spine films; Back films ... The test is done in a hospital radiology department or in the health care provider's office. You will lie on the x-ray table in different positions. If the x-ray ...

  5. Thoracic Pedicle Screw Placement Guide Plate Produced by Three-Dimensional (3-D) Laser Printing

    PubMed Central

    Chen, Hongliang; Guo, Kaijing; Yang, Huilin; Wu, Dongying; Yuan, Feng

    2016-01-01

    Background The aim of this study was to evaluate the accuracy and feasibility of an individualized thoracic pedicle screw placement guide plate produced by 3-D laser printing. Material/Methods Thoracic pedicle samples of 3 adult cadavers were randomly assigned for 3-D CT scans. The 3-D thoracic models were established by using medical Mimics software, and a screw path was designed with scanned data. Then the individualized thoracic pedicle screw placement guide plate models, matched to the backside of thoracic vertebral plates, were produced with a 3-D laser printer. Screws were placed with assistance of a guide plate. Then, the placement was assessed. Results With the data provided by CT scans, 27 individualized guide plates were produced by 3-D printing. There was no significant difference in sex and relevant parameters of left and right sides among individuals (P>0.05). Screws were placed with assistance of guide plates, and all screws were in the correct positions without penetration of pedicles, under direct observation and anatomic evaluation post-operatively. Conclusions A thoracic pedicle screw placement guide plate can be produced by 3-D printing. With a high accuracy in placement and convenient operation, it provides a new method for accurate placement of thoracic pedicle screws. PMID:27194139

  6. Long thoracic nerve injury.

    PubMed

    Wiater, J M; Flatow, E L

    1999-11-01

    Injury to the long thoracic nerve causing paralysis or weakness of the serratus anterior muscle can be disabling. Patients with serratus palsy may present with pain, weakness, limitation of shoulder elevation, and scapular winging with medial translation of the scapula, rotation of the inferior angle toward the midline, and prominence of the vertebral border. Long thoracic nerve dysfunction may result from trauma or may occur without injury. Fortunately, most patients experience a return of serratus anterior function with conservative treatment, but recovery may take as many as 2 years. Bracing often is tolerated poorly. Patients with severe symptoms in whom 12 months of conservative treatment has failed may benefit from surgical reconstruction. Although many surgical procedures have been described, the current preferred treatment is transfer of the sternal head of the pectoralis major tendon to the inferior angle of the scapula reinforced with fascia or tendon autograft. Many series have shown good to excellent results, with consistent improvement in function, elimination of winging, and reduction of pain.

  7. Thoracic damage control surgery.

    PubMed

    Gonçalves, Roberto; Saad, Roberto

    2016-01-01

    The damage control surgery came up with the philosophy of applying essential maneuvers to control bleeding and abdominal contamination in trauma patients who are within the limits of their physiological reserves. This concept was extended to thoracic injuries, where relatively simple maneuvers can shorten operative time of in extremis patients. This article aims to revise the various damage control techniques in thoracic organs that must be known to the surgeon engaged in emergency care. RESUMO A cirurgia de controle de danos surgiu com a filosofia de se aplicar manobras essenciais para controle de sangramento e contaminação abdominal, em doentes traumatizados, nos limites de suas reservas fisiológicas. Este conceito se estendeu para as lesões torácicas, onde manobras relativamente simples, podem abreviar o tempo operatório de doentes in extremis. Este artigo tem como objetivo, revisar as diversas técnicas de controle de dano em órgãos torácicos, que devem ser de conhecimento do cirurgião que atua na emergência.

  8. SU-E-T-428: Feasibility Study of 4D Image Reconstruction by Organ Motion Vector Extension Based On Portal Images

    SciTech Connect

    Yoon, J; Jung, J; Yeo, I; Kim, J; Yi, B

    2015-06-15

    Purpose: To develop and to test a method to generate a new 4D CT images of the treatment day from the old 4D CT and the portal images of the day when the motion extent exceeded from that represented by plan CTs. Methods: A motion vector of a moving tumor in a patient may be extended to reconstruct the tumor position when the motion extent exceeded from that represented by plan CTs. To test this, 1. a phantom that consists of a polystyrene cylinder (tumor) embedded in cork (lung) was placed on a moving platform with 4 sec/cycle and amplitudes of 1 cm and 2 cm, and was 4D-scanned. 2. A 6MV photon beam was irradiated on the moving phantoms and cineEPID images were obtained. 3. A motion vector of the tumor was acquired from 4D CT images of the phantom with 1 cm amplitude. 4. From cine EPID images of the phantom with the 2 cm amplitude, various motion extents (0.3 cm, 0.5 cm, etc) were acquired and programmed into the motion vector, producing CT images at each position. 5. The reconstructed CT images were then compared with pre-acquired “reference” 4D CT images at each position (i.e. phase). Results: The CT image was reconstructed and compared with the reference image, showing a slight mismatch in the transition direction limited by voxel size (slice thickness) in CT image. Due to the rigid nature of the phantom studied, the modeling the displacement of the center of object was sufficient. When deformable tumors are to be modeled, more complex scheme is necessary, which utilize cine EPID and 4D CT images. Conclusion: The new idea of CT image reconstruction was demonstrated. Deformable tumor movements need to be considered in the future.

  9. CT Enterography

    MedlinePlus

    ... obstructions and Crohn’s disease. CT scanning is fast, painless, noninvasive and accurate. CT enterography is better able ... the benefits vs. risks? Benefits CT scanning is painless, noninvasive and accurate. A major advantage of CT ...

  10. Long thoracic nerve paralysis associated with thoracic outlet syndrome.

    PubMed

    Nakatsuchi, Y; Saitoh, S; Hosaka, M; Uchiyama, S

    1994-01-01

    Two cases of long thoracic nerve palsy associated with thoracic outlet syndrome are reported. Both patients had abnormal posture, with low-set shoulders and winged scapulae. Clinically there was weakness of the serratus anterior muscle with partial denervotion on electromyography. The diagnosis of thoracic outlet syndrome was based on positive vascular tests and brachial plexus nerve compression symptoms induced by the vascular testing positions. An orthosis that held the shoulder in an elevated position was used in both cases. Complete recovery of shoulder function and relief of the symptoms was achieved in both cases at 8 and 13 months, respectively, after application of the orthosis.

  11. 17 CFR 260.4d-8 - Content.

    Code of Federal Regulations, 2010 CFR

    2011-04-01

    ... 17 Commodity and Securities Exchanges 3 2011-04-01 2011-04-01 false Content. 260.4d-8 Section 260.4d-8 Commodity and Securities Exchanges SECURITIES AND EXCHANGE COMMISSION (CONTINUED) GENERAL RULES AND REGULATIONS, TRUST INDENTURE ACT OF 1939 Rules Under Section 304 § 260.4d-8 Content. (a)...

  12. 17 CFR 260.4d-8 - Content.

    Code of Federal Regulations, 2010 CFR

    2012-04-01

    ... 17 Commodity and Securities Exchanges 3 2012-04-01 2012-04-01 false Content. 260.4d-8 Section 260.4d-8 Commodity and Securities Exchanges SECURITIES AND EXCHANGE COMMISSION (CONTINUED) GENERAL RULES AND REGULATIONS, TRUST INDENTURE ACT OF 1939 Rules Under Section 304 § 260.4d-8 Content. (a)...

  13. 17 CFR 260.4d-8 - Content.

    Code of Federal Regulations, 2010 CFR

    2000-04-01

    ... 17 Commodity and Securities Exchanges 3 2000-04-01 2000-04-01 false Content. 260.4d-8 Section 260.4d-8 Commodity and Securities Exchanges GENERAL RULES AND REGULATIONS, TRUST INDENTURE ACT OF 1939 Rules Under Section 304 § 260.4d-8 Content. (a) Each application for an order under section 304(d)...

  14. 17 CFR 260.4d-8 - Content.

    Code of Federal Regulations, 2010 CFR

    2005-04-01

    ... 17 Commodity and Securities Exchanges 3 2005-04-01 2005-04-01 false Content. 260.4d-8 Section 260.4d-8 Commodity and Securities Exchanges SECURITIES AND EXCHANGE COMMISSION (CONTINUED) GENERAL RULES AND REGULATIONS, TRUST INDENTURE ACT OF 1939 Rules Under Section 304 § 260.4d-8 Content. (a)...

  15. Thoracic involvement in Behçet's disease and its correlation with multiple parameters.

    PubMed

    Gunen, H; Evereklioglu, C; Kosar, F; Er, H; Kizkin, O

    2000-01-01

    In Behçet's disease (BD), controversy has existed over the incidence of thoracic involvement, which may be a direct threat to the patient's life. The aim of this study is to evaluate the incidence of thoracic involvement in BD and its correlation with the number of diagnostic BD criteria of The International Study Group (ISG), gender, disease duration, and the presence of symptoms. Forty-two BD patients, who had consecutively applied to different clinics in Turgut Ozal Medical Center Research Hospital, were included in the study. They were either newly diagnosed or already under treatment. All patients were examined by standard chest roentgenogram, spirometry, and thorax CT. Perfusion scintigraphies were obtained in patients with thoracic involvement. Thoracic pathologic conditions were found in five patients (11.9%). All thoracic pathologic conditions appeared in patients with at least four diagnostic criteria (26 patients) of the ISG for BD. In this subgroup, the rate of thoracic involvement was 19.2%. Also, 25% of the patients with pulmonary symptoms (12 patients) had thoracic lesions. Gender and the duration of the disease did not correlate with thoracic involvement. Our findings suggest that the rate of thoracic involvement in BD is greater than is generally believed. An increased number of diagnostic BD criteria of the ISG may indicate other organ system involvement and an increased risk of thoracic pathosis. All BD patients with at least four diagnostic criteria or any pulmonary symptoms should be evaluated for thoracic involvement, which is a major menace to life and necessitates early intervention.

  16. Evaluation of the Elekta Symmetry ™ 4D IGRT system by using a moving lung phantom

    NASA Astrophysics Data System (ADS)

    Shin, Hun-Joo; Kim, Shin-Wook; Kay, Chul Seung; Seo, Jae-Hyuk; Lee, Gi-Woong; Kang, Ki-Mun; Jang, Hong Seok; Kang, Young-nam

    2015-07-01

    Purpose: 4D cone-beam computed tomography (CBCT) is a beneficial tool for the treatment of movable tumors because it can help us to understand where the tumors are actually located and it has a precise treatment plan. However, general CBCT images have a limitation in that they cannot perfectly perform a sophisticated registration. On the other hand, the Symmetry TM 4D image-guided radiation therapy (IGRT) system of Elekta offers a 4D CBCT registration option. In this study, we evaluated the usefulness of Symmetry TM . Method and Materials: Planning CT images of the CIRS moving lung phantom were acquired 4D multi-detector CT (MDCT), and the images were sorted as 10 phases from 0% phase to 90% phase. The thickness of the CT images was 1 mm. Acquired MDCT images were transferred to the contouring software, and a virtual target was generated. A one-arc volumetric-modulated arc therapy (VMAT) plan was performed by using the treatment planning system on the virtual target. Finally, the movement of the phantom was verified by using the XVI Symmetry TM system. Results: The physical movement of the CIRS moving lung phantom was ±10.0 mm in the superiorinferior direction, ±1.0 mm in the lateral direction, and ±2.5 mm in the anterior-posterior direction. The movement of the phantom was measured from the 4D MDCT registration as ±10.2 mm in the superior-inferior direction, ±0.9 mm in the lateral direction, and ±2.45 mm in the anterior-posterior direction. The movement of the phantom was measured from the SymmetryTM registration as ±10.1 mm in the superior-inferior direction, ±0.9 mm in the lateral direction, and ±2.4 mm in the anterior-posterior direction. Conclusion: We confirmed that 4D CBCT is a beneficial tool for the treatment of movable tumors, and that the 4D registration of SymmetryTM can increase the precision of the registration when a movable tumor is the target of radiation treatment.

  17. [Thoracic kidney: congenital or traumatic origin?].

    PubMed

    Esquis, P; Osmak, L; Ognois, P; Goudet, P; Cougard, P

    2006-04-01

    The discovery of a thoracic kidney in adult patients can lead to three diagnoses, yielding different prognoses and treatment. It can either mean traumatic or congenital diaphragmatic hernia, or a congenital ectopic kidney. Intrathoracic herniation of the left kidney trough a left diaphragmatic rupture is an exceptional discovery. We report the case of a 44 year-old man who met with a car accident 20 years ago, and presented abdominal pain. CT-scan showed an intrathoracic herniation of the left kidney trough a left posterior diaphragmatic rupture. Laparoscopic approach in lateral position showed a traumatic hernia of the left costo-diaphragmatic hiatus only containing the left kidney and its pedicle. After reduction of herniated left kidney into the abdomen, the hiatus was closed by non-resorbable prosthetic mesh. Postoperative course was uneventful.

  18. A reappraisal of adult thoracic surface anatomy.

    PubMed

    Mirjalili, S Ali; Hale, Samuel J M; Buckenham, Tim; Wilson, Ben; Stringer, Mark D

    2012-10-01

    Accurate surface anatomy is essential for safe clinical practice. Numerous inconsistencies in clinically important surface markings exist between and within anatomical reference texts. The aim of this study was to investigate key thoracic surface anatomical landmarks in vivo using computed tomographic (CT) imaging. High-resolution thoracic CT scans from 153 supine adults (mean age 63, range 19-89 years; 53% female) taken at end tidal inspiration were analyzed by dual consensus reporting to determine the surface anatomy of the sternal angle, central veins, heart, lungs, and diaphragm. Patients with kyphosis/scoliosis, distorting space-occupying lesions, or visceromegaly were excluded. The position of the cardiac apex, formation of the brachiocephalic veins, and vertebral levels of the sternal angle, xiphisternal joint, and aortic hiatus were consistent with commonly accepted surface markings although there was a wide range of normal variation. In contrast, common surface markings were markedly inaccurate for the following: the position of the tracheal bifurcation, aortic arch, and azygos vein termination (below the plane of the sternal angle at T5-T6 vertebral level in most individuals); the superior vena cava/right atrial junction (most often behind the fourth costal cartilage); the lower border of the lung (adjacent to T12 vertebra posteriorly); and the level at which the inferior vena cava and esophagus traverse the diaphragm (T11 in most). Surface anatomy must be reappraised using modern imaging in vivo if it is to be evidence based and fit for purpose. The effects of gender, age, posture, respiration, build, and ethnicity also deserve greater emphasis.

  19. Automated contour mapping using sparse volume sampling for 4D radiation therapy

    SciTech Connect

    Chao Ming; Schreibmann, Eduard; Li Tianfang; Wink, Nicole; Xing Lei

    2007-10-15

    The purpose of this work is to develop a novel strategy to automatically map organ contours from one phase of respiration to all other phases on a four-dimensional computed tomography (4D CT). A region of interest (ROI) was manually delineated by a physician on one phase specific image set of a 4D CT. A number of cubic control volumes of the size of {approx}1 cm were automatically placed along the contours. The control volumes were then collectively mapped to the next phase using a rigid transformation. To accommodate organ deformation, a model-based adaptation of the control volume positions was followed after the rigid mapping procedure. This further adjustment of control volume positions was performed by minimizing an energy function which balances the tendency for the control volumes to move to their correspondences with the desire to maintain similar image features and shape integrity of the contour. The mapped ROI surface was then constructed based on the central positions of the control volumes using a triangulated surface construction technique. The proposed technique was assessed using a digital phantom and 4D CT images of three lung patients. Our digital phantom study data indicated that a spatial accuracy better than 2.5 mm is achievable using the proposed technique. The patient study showed a similar level of accuracy. In addition, the computational speed of our algorithm was significantly improved as compared with a conventional deformable registration-based contour mapping technique. The robustness and accuracy of this approach make it a valuable tool for the efficient use of the available spatial-tempo information for 4D simulation and treatment.

  20. 4D electron microscopy: principles and applications.

    PubMed

    Flannigan, David J; Zewail, Ahmed H

    2012-10-16

    achievable with short intense pulses containing a large number of electrons, however, are limited to tens of nanometers and nanoseconds, respectively. This is because Coulomb repulsion is significant in such a pulse, and the electrons spread in space and time, thus limiting the beam coherence. It is therefore not possible to image the ultrafast elementary dynamics of complex transformations. The challenge was to retain the high spatial resolution of a conventional TEM while simultaneously enabling the temporal resolution required to visualize atomic-scale motions. In this Account, we discuss the development of four-dimensional ultrafast electron microscopy (4D UEM) and summarize techniques and applications that illustrate the power of the approach. In UEM, images are obtained either stroboscopically with coherent single-electron packets or with a single electron bunch. Coulomb repulsion is absent under the single-electron condition, thus permitting imaging, diffraction, and spectroscopy, all with high spatiotemporal resolution, the atomic scale (sub-nanometer and femtosecond). The time resolution is limited only by the laser pulse duration and energy carried by the electron packets; the CCD camera has no bearing on the temporal resolution. In the regime of single pulses of electrons, the temporal resolution of picoseconds can be attained when hundreds of electrons are in the bunch. The applications given here are selected to highlight phenomena of different length and time scales, from atomic motions during structural dynamics to phase transitions and nanomechanical oscillations. We conclude with a brief discussion of emerging methods, which include scanning ultrafast electron microscopy (S-UEM), scanning transmission ultrafast electron microscopy (ST-UEM) with convergent beams, and time-resolved imaging of biological structures at ambient conditions with environmental cells.

  1. TU-F-17A-08: The Relative Accuracy of 4D Dose Accumulation for Lung Radiotherapy Using Rigid Dose Projection Versus Dose Recalculation On Every Breathing Phase

    SciTech Connect

    Lamb, J; Lee, C; Tee, S; Lee, P; Iwamoto, K; Low, D; Valdes, G; Robinson, C

    2014-06-15

    Purpose: To investigate the accuracy of 4D dose accumulation using projection of dose calculated on the end-exhalation, mid-ventilation, or average intensity breathing phase CT scan, versus dose accumulation performed using full Monte Carlo dose recalculation on every breathing phase. Methods: Radiotherapy plans were analyzed for 10 patients with stage I-II lung cancer planned using 4D-CT. SBRT plans were optimized using the dose calculated by a commercially-available Monte Carlo algorithm on the end-exhalation 4D-CT phase. 4D dose accumulations using deformable registration were performed with a commercially available tool that projected the planned dose onto every breathing phase without recalculation, as well as with a Monte Carlo recalculation of the dose on all breathing phases. The 3D planned dose (3D-EX), the 3D dose calculated on the average intensity image (3D-AVE), and the 4D accumulations of the dose calculated on the end-exhalation phase CT (4D-PR-EX), the mid-ventilation phase CT (4D-PR-MID), and the average intensity image (4D-PR-AVE), respectively, were compared against the accumulation of the Monte Carlo dose recalculated on every phase. Plan evaluation metrics relating to target volumes and critical structures relevant for lung SBRT were analyzed. Results: Plan evaluation metrics tabulated using 4D-PR-EX, 4D-PR-MID, and 4D-PR-AVE differed from those tabulated using Monte Carlo recalculation on every phase by an average of 0.14±0.70 Gy, - 0.11±0.51 Gy, and 0.00±0.62 Gy, respectively. Deviations of between 8 and 13 Gy were observed between the 4D-MC calculations and both 3D methods for the proximal bronchial trees of 3 patients. Conclusions: 4D dose accumulation using projection without re-calculation may be sufficiently accurate compared to 4D dose accumulated from Monte Carlo recalculation on every phase, depending on institutional protocols. Use of 4D dose accumulation should be considered when evaluating normal tissue complication

  2. Motion4D-library extended

    NASA Astrophysics Data System (ADS)

    Müller, Thomas

    2011-06-01

    The new version of the Motion4D-library now also includes the integration of a Sachs basis and the Jacobi equation to determine gravitational lensing of pointlike sources for arbitrary spacetimes.New version program summaryProgram title: Motion4D-libraryCatalogue identifier: AEEX_v3_0Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AEEX_v3_0.htmlProgram obtainable from: CPC Program Library, Queen's University, Belfast, N. IrelandLicensing provisions: Standard CPC licence, http://cpc.cs.qub.ac.uk/licence/licence.htmlNo. of lines in distributed program, including test data, etc.: 219 441No. of bytes in distributed program, including test data, etc.: 6 968 223Distribution format: tar.gzProgramming language: C++Computer: All platforms with a C++ compilerOperating system: Linux, WindowsRAM: 61 MbytesClassification: 1.5External routines: Gnu Scientic Library (GSL) (http://www.gnu.org/software/gsl/)Catalogue identifier of previous version: AEEX_v2_0Journal reference of previous version: Comput. Phys. Comm. 181 (2010) 703Does the new version supersede the previous version?: YesNature of problem: Solve geodesic equation, parallel and Fermi-Walker transport in four-dimensional Lorentzian spacetimes. Determine gravitational lensing by integration of Jacobi equation and parallel transport of Sachs basis.Solution method: Integration of ordinary differential equations.Reasons for new version: The main novelty of the current version is the extension to integrate the Jacobi equation and the parallel transport of the Sachs basis along null geodesics. In combination, the change of the cross section of a light bundle and thus the gravitational lensing effect of a spacetime can be determined. Furthermore, we have implemented several new metrics.Summary of revisions: The main novelty of the current version is the integration of the Jacobi equation and the parallel transport of the Sachs basis along null geodesics. The corresponding set of equations readd2xμdλ2=-Γρ

  3. The evolution of thoracic anesthesia.

    PubMed

    Brodsky, Jay B

    2005-02-01

    The specialty of thoracic surgery has evolved along with the modem practice of anesthesia. This close relationship began in the 1930s and continues today. Thoracic surgery has grown from a field limited almost exclusively to simple chest wall procedures to the present situation in which complex procedures, such as lung volume reduction or lung transplantation, now can be performed on the most severely compromised patient. The great advances in thoracic surgery have followed discoveries and technical innovations in many medical fields. One of the most important reasons for the rapid escalation in the number and complexity of thoracic surgical procedures now being performed has been the evolution of anesthesia for thoracic surgery. There has been so much progress in this area that numerous books and journals are devoted entirely to this subject. The author has been privileged to work with several surgeons who specialized in noncardiac thoracic surgery. As a colleague of 25 years, the noted pulmonary surgeon James B.D. Mark wrote, "Any operation is a team effort... (but) nowhere is this team effort more important than in thoracic surgery, where near-choreography of moves by all participants is essential. Exchange of information, status and plans are mandatory". This team approach between the thoracic surgeon and the anesthesiologist reflects the history of the two specialties. With new advances in technology, such as continuous blood gas monitoring and the pharmacologic management of pulmonary circulation to maximize oxygenation during one-lung ventilation, in the future even more complex procedures may be able to be performed safely on even higher risk patients.

  4. A proposed framework for consensus-based lung tumour volume auto-segmentation in 4D computed tomography imaging

    NASA Astrophysics Data System (ADS)

    Martin, Spencer; Brophy, Mark; Palma, David; Louie, Alexander V.; Yu, Edward; Yaremko, Brian; Ahmad, Belal; Barron, John L.; Beauchemin, Steven S.; Rodrigues, George; Gaede, Stewart

    2015-02-01

    This work aims to propose and validate a framework for tumour volume auto-segmentation based on ground-truth estimates derived from multi-physician input contours to expedite 4D-CT based lung tumour volume delineation. 4D-CT datasets of ten non-small cell lung cancer (NSCLC) patients were manually segmented by 6 physicians. Multi-expert ground truth (GT) estimates were constructed using the STAPLE algorithm for the gross tumour volume (GTV) on all respiratory phases. Next, using a deformable model-based method, multi-expert GT on each individual phase of the 4D-CT dataset was propagated to all other phases providing auto-segmented GTVs and motion encompassing internal gross target volumes (IGTVs) based on GT estimates (STAPLE) from each respiratory phase of the 4D-CT dataset. Accuracy assessment of auto-segmentation employed graph cuts for 3D-shape reconstruction and point-set registration-based analysis yielding volumetric and distance-based measures. STAPLE-based auto-segmented GTV accuracy ranged from (81.51  ±  1.92) to (97.27  ±  0.28)% volumetric overlap of the estimated ground truth. IGTV auto-segmentation showed significantly improved accuracies with reduced variance for all patients ranging from 90.87 to 98.57% volumetric overlap of the ground truth volume. Additional metrics supported these observations with statistical significance. Accuracy of auto-segmentation was shown to be largely independent of selection of the initial propagation phase. IGTV construction based on auto-segmented GTVs within the 4D-CT dataset provided accurate and reliable target volumes compared to manual segmentation-based GT estimates. While inter-/intra-observer effects were largely mitigated, the proposed segmentation workflow is more complex than that of current clinical practice and requires further development.

  5. A study on quantitative analysis of field size and dose by using gating system in 4D conformal radiation treatment

    NASA Astrophysics Data System (ADS)

    Ji, Youn-Sang; Dong, Kyung-Rae; Kim, Chang-Bok; Chung, Woon-Kwan; Cho, Jae-Hwan; Lee, Hae-Kag

    2012-10-01

    This study evaluated the gating-based 4-D conformal radiation therapy (4D-CT) treatment planning by a comparison with the common 3-D conformal radiation therapy (3D-CT) treatment planning and examined the change in treatment field size and dose to the tumors and adjacent normal tissues because an unnecessary dose is also included in the 3-D treatment planning for the radiation treatment of tumors in the chest and abdomen. The 3D-CT and gating-based 4D-CT images were obtained from patients who had undergone radiation treatment for chest and abdomen tumors in the oncology department. After establishing a treatment plan, the CT treatment and planning system were used to measure the change in field size for analysis. A dose volume histogram (DVH) was used to calculate the appropriate dose to planning target volume (PTV) tumors and adjacent normal tissue. The difference in the treatment volume of the chest was 0.6 and 0.83 cm on the X- and Y-axis, respectively, for the gross tumor volume (GTV). Accordingly, the values in the 4D-CT treatment planning were smaller and the dose was more concentrated by 2.7% and 0.9% on the GTV and clinical target volume (CTV), respectively. The normal tissues in the surrounding normal tissues were reduced by 3.0%, 7.2%, 0.4%, 1.7%, 2.6% and 0.2% in the bronchus, chest wall, esophagus, heart, lung and spinal cord, respectively. The difference in the treatment volume of the abdomen was 0.72 cm on the X-axis and 0.51 cm on the Y-axis for the GTV; and 1.06 cm on the X-axis and 1.85 cm on the Y-axis for the PTV. Therefore, the values in the 4D-CT treatment planning were smaller. The dose was concentrated by 6.8% and 4.3% on the GTV and PTV, respectively, whereas the adjacent normal tissues in the cord, Lt. kidney, Rt. kidney, small bowels and whole liver were reduced by 3.2%, 4.2%, 1.5%, 6.2% and 12.7%, respectively. The treatment field size was smaller in volume in the case of the 4D-CT treatment planning. In the DVH, the 4D-CT treatment

  6. 17 CFR 260.4d-8 - Content.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 17 Commodity and Securities Exchanges 3 2013-04-01 2013-04-01 false Content. 260.4d-8 Section 260.4d-8 Commodity and Securities Exchanges SECURITIES AND EXCHANGE COMMISSION (CONTINUED) GENERAL RULES AND REGULATIONS, TRUST INDENTURE ACT OF 1939 Rules Under Section 304 § 260.4d-8 Content. (a) Each application for an order under section 304(d)...

  7. 17 CFR 260.4d-8 - Content.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 17 Commodity and Securities Exchanges 4 2014-04-01 2014-04-01 false Content. 260.4d-8 Section 260.4d-8 Commodity and Securities Exchanges SECURITIES AND EXCHANGE COMMISSION (CONTINUED) GENERAL RULES AND REGULATIONS, TRUST INDENTURE ACT OF 1939 Rules Under Section 304 § 260.4d-8 Content. (a) Each application for an order under section 304(d)...

  8. 17 CFR 260.4d-8 - Content.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false Content. 260.4d-8 Section 260.4d-8 Commodity and Securities Exchanges SECURITIES AND EXCHANGE COMMISSION (CONTINUED) GENERAL RULES AND REGULATIONS, TRUST INDENTURE ACT OF 1939 Rules Under Section 304 § 260.4d-8 Content. (a) Each application for an order under section 304(d)...

  9. Killing Weeds with 2,4-D. Extension Bulletin 389.

    ERIC Educational Resources Information Center

    Lee, Oliver C.

    Discussed is the use of the herbicide 2,4-D. Though written for farmers and agricultural workers, the pamphlet considers turf weed control and use of 2,4-D near ornamental plants. Aspects of the use of this herbicide covered are: (1) the common forms of 2,4-D; (2) plant responses and tolerances to the herbicide; (3) dilution and concentration of…

  10. Automated 4D lung computed tomography reconstruction during free breathing for conformal radiation therapy

    NASA Astrophysics Data System (ADS)

    El Naqa, Issam M.; Low, Daniel A.; Christensen, Gary E.; Parikh, Parag J.; Song, Joo Hyun; Nystrom, Michelle M.; Lu, Wei; Deasy, Joseph O.; Hubenschmidt, James P.; Wahab, Sasha H.; Mutic, Sasa; Singh, Anurag K.; Bradley, Jeffrey D.

    2004-04-01

    We are developing 4D-CT to provide breathing motion information (trajectories) for radiation therapy treatment planning of lung cancer. Potential applications include optimization of intensity-modulated beams in the presence of breathing motion and intra-fraction target volume margin determination for conformal therapy. The images are acquired using a multi-slice CT scanner while the patient undergoes simultaneous quantitative spirometry. At each couch position, the CT scanner is operated in ciné mode and acquires up to 15 scans of 12 slices each. Each CT scan is associated with the measured tidal volume for retrospective reconstruction of 3D CT scans at arbitrary tidal volumes. The specific tasks of this project involves the development of automated registration of internal organ motion (trajectories) during breathing. A modified least-squares based optical flow algorithm tracks specific features of interest by modifying the eigenvalues of gradient matrix (gradient structural tensor). Good correlations between the measured motion and spirometry-based tidal volume are observed and evidence of internal hysteresis is also detected.

  11. Direct Visuo-Haptic 4D Volume Rendering Using Respiratory Motion Models.

    PubMed

    Fortmeier, Dirk; Wilms, Matthias; Mastmeyer, Andre; Handels, Heinz

    2015-01-01

    This article presents methods for direct visuo-haptic 4D volume rendering of virtual patient models under respiratory motion. Breathing models are computed based on patient-specific 4D CT image data sequences. Virtual patient models are visualized in real-time by ray casting based rendering of a reference CT image warped by a time-variant displacement field, which is computed using the motion models at run-time. Furthermore, haptic interaction with the animated virtual patient models is provided by using the displacements computed at high rendering rates to translate the position of the haptic device into the space of the reference CT image. This concept is applied to virtual palpation and the haptic simulation of insertion of a virtual bendable needle. To this aim, different motion models that are applicable in real-time are presented and the methods are integrated into a needle puncture training simulation framework, which can be used for simulated biopsy or vessel puncture in the liver. To confirm real-time applicability, a performance analysis of the resulting framework is given. It is shown that the presented methods achieve mean update rates around 2,000 Hz for haptic simulation and interactive frame rates for volume rendering and thus are well suited for visuo-haptic rendering of virtual patients under respiratory motion.

  12. Can pre-operative computed tomography predict the need for a thoracic approach for removal of retrosternal goitre?

    PubMed

    Qureishi, Ali; Garas, George; Tolley, Neil; Palazzo, Fausto; Athanasiou, Thanos; Zacharakis, Emmanouil

    2013-01-01

    A best evidence topic was written according to a structured protocol. The question addressed was whether in patients with retrosternal goitre the need for a thoracic approach can be predicted using pre-operative CT. A total of 381 papers were identified using the reported search protocol of which 7 represented the best evidence to answer the clinical question. The authors, journal, date, country of publication, patient group studied, study type, relevant outcomes and results are tabulated. The evidence on this subject is poor, none of the studies were randomised, only one used controls (historical) and all studies were retrospective. Despite these limitations, CT represents the gold-standard imaging modality in the pre-operative evaluation of patients with retrosternal goitre. CT is essential to define the extent and position of a retrosternal goitre. The literature suggests that CT is the single most valuable pre-operative investigation predicting whether a sternotomy or lateral thoracotomy will be necessary for removal of the retrosternal goitre. Although pre-operative CT does not have the precision to predict whether a thoracic approach is required in all cases, the presence of certain radiological features such as extension of the goitre below the aortic arch or into the posterior mediastinum, a dumbbell shape and a thoracic component that is wider than the thoracic inlet are all associated with the need for a thoracic approach. In some cases a pre-operative CT will not only determine that a thoracic approach is mandatory but it will also guide the surgeon upon the type of thoracic approach.

  13. Experimental investigation of irregular motion impact on 4D PET-based particle therapy monitoring

    NASA Astrophysics Data System (ADS)

    Tian, Y.; Stützer, K.; Enghardt, W.; Priegnitz, M.; Helmbrecht, S.; Bert, C.; Fiedler, F.

    2016-01-01

    Particle therapy positron emission tomography (PT-PET) is an in vivo and non-invasive imaging technique to monitor treatment delivery in particle therapy. The inevitable patient respiratory motion during irradiation causes artefacts and inaccurate activity distribution in PET images. Four-dimensional (4D) maximum likelihood expectation maximisation (4D MLEM) allows for a compensation of these effects, but has up to now been restricted to regular motion for PT-PET investigations. However, intra-fractional motion during treatment might differ from that during acquisition of the 4D-planning CT (e.g. amplitude variation, baseline drift) and therefore might induce inaccurate 4D PET reconstruction results. This study investigates the impact of different irregular analytical one-dimensional (1D) motion patterns on PT-PET imaging by means of experiments with a radioactive source and irradiated moving phantoms. Three sorting methods, namely phase sorting, equal amplitude sorting and event-based amplitude sorting, were applied to manage the PET list-mode data. The influence of these sorting methods on the motion compensating algorithm has been analysed. The event-based amplitude sorting showed a superior performance and it is applicable for irregular motions with  ⩽4 mm amplitude elongation and drift. For motion with 10 mm baseline drift, the normalised root mean square error was as high as 10.5% and a 10 mm range deviation was observed.

  14. VMAT QA: Measurement-guided 4D dose reconstruction on a patient

    SciTech Connect

    Nelms, Benjamin E.; Opp, Daniel; Robinson, Joshua; Wolf, Theresa K.; Zhang, Geoffrey; Moros, Eduardo; Feygelman, Vladimir

    2012-07-15

    global fluence change. Results: Across four TG-119 plans, the average PTV point dose difference in the cube between 3DVH and ion chamber is 0.1 {+-} 1.0%. Average film vs TPS {gamma}-analysis passing rates are 83.0%, 91.1%, and 98.4% for 1%/2 mm, 2%/2 mm, and 3%/3 mm threshold combinations, respectively, while average film vs 3DVH {gamma}-analysis passing rates are 88.6%, 96.1%, and 99.5% for the same respective criteria. 4D MGDR was also sufficiently accurate. First, for 99.5% voxels in each case, the doses from 3D and 4D MGDR at the end of delivery agree within 0.5%local dose-error/1 mm distance. Moreover, all failing voxels are confined to the edge of the cylindrical reconstruction volume. Second, dose vs time curves track between the ion chamber and 4D MGDR within 1%. Finally, 4D MGDR dose changes linearly with the accelerator output: the difference between cumulative ion chamber and MGDR dose changed by no more than 1% (randomly) with the output variation range of 10%. Conclusions: Even for a well-commissioned TPS, comparison metrics show better agreement on average to MGDR than to TPS on the arbitrary-shaped measurable 'patient.' The method requires no more accelerator time than standard QA, while producing more clinically relevant information. Validation in a heterogeneous thoracic phantom is under way, as is the ultimate application of 4D MGDR to virtual motion studies.

  15. Bone scaffolds loaded with siRNA-Semaphorin4d for the treatment of osteoporosis related bone defects

    PubMed Central

    Zhang, Yufeng; Wei, Lingfei; Miron, Richard J.; Shi, Bin; Bian, Zhuan

    2016-01-01

    Osteoporosis is a prominent disorder affecting over 200 million people worldwide. Recently, semaphorins have been implicated in the cell-cell communication between osteoclasts and osteoblasts and have been associated with the progression of osteoporosis. Previously, we demonstrated that knockdown of semaphorin4d (Sema4d) using siRNA delivered with a bone-targeting system prevented bone loss in an osteoporotic animal model. Here, we used this bone-specific technology containing siRNA-Sema4d and fabricated a PLLA scaffold capable of enhancing bone repair following fracture. We investigated the ability of the implant to release siRNA-Sema4d into the surrounding tissues over time and to influence new bone formation in a 3 mm femur osteoporotic defect model in ovariectomized rats. Delivery of the bone-targeting system released from PLLA scaffolds began 2 hours post-implantation, peaked at 1 day, and was sustained over a 21 day period. μCT analysis demonstrated a significantly higher bone volume/total volume bone mineral density and number of osteoblasts in the rats that were transplanted with scaffolds loaded with siRNA-Sema4d. These results confirm the specific role of Sema4d in bone remodeling and demonstrate that significant increases in the speed and quality of new bone formation occur when siRNA-Sema4d is delivered via a PLLA scaffold. PMID:27254469

  16. A method for deriving a 4D-interpolated balanced planning target for mobile tumor radiotherapy

    SciTech Connect

    Roland, Teboh; Hales, Russell; McNutt, Todd; Wong, John; Simari, Patricio; Tryggestad, Erik

    2012-01-15

    Purpose: Tumor control and normal tissue toxicity are strongly correlated to the tumor and normal tissue volumes receiving high prescribed dose levels in the course of radiotherapy. Planning target definition is, therefore, crucial to ensure favorable clinical outcomes. This is especially important for stereotactic body radiation therapy of lung cancers, characterized by high fractional doses and steep dose gradients. The shift in recent years from population-based to patient-specific treatment margins, as facilitated by the emergence of 4D medical imaging capabilities, is a major improvement. The commonly used motion-encompassing, or internal-target volume (ITV), target definition approach provides a high likelihood of coverage for the mobile tumor but inevitably exposes healthy tissue to high prescribed dose levels. The goal of this work was to generate an interpolated balanced planning target that takes into account both tumor coverage and normal tissue sparing from high prescribed dose levels, thereby improving on the ITV approach. Methods: For each 4DCT dataset, 4D deformable image registration was used to derive two bounding targets, namely, a 4D-intersection and a 4D-composite target which minimized normal tissue exposure to high prescribed dose levels and maximized tumor coverage, respectively. Through definition of an ''effective overlap volume histogram'' the authors derived an ''interpolated balanced planning target'' intended to balance normal tissue sparing from prescribed doses with tumor coverage. To demonstrate the dosimetric efficacy of the interpolated balanced planning target, the authors performed 4D treatment planning based on deformable image registration of 4D-CT data for five previously treated lung cancer patients. Two 4D plans were generated per patient, one based on the interpolated balanced planning target and the other based on the conventional ITV target. Plans were compared for tumor coverage and the degree of normal tissue sparing

  17. Gallium-67 thoracic scan and pleural disease in asbestos workers

    SciTech Connect

    Lambert, R.; Bisson, G.; Lamoureux, G.; Begin, R.

    1985-06-01

    The authors have recently reported that /sup 67/Ga scanning in asbestos workers can document excessive uptake of the marker among workers without sufficient criteria for asbestosis, but in their initial report they could not exclude definitely that /sup 67/Ga uptake could be related to pleural disease. To further test this hypothesis, they analyzed the /sup 67/Ga thoracic scan in relation to profusion scores of pleural disease on chest roentgenogram and CT scan of the thorax in 171 asbestos workers. They found no significant correlation between the /sup 67/Ga lung uptake and the radiographic scores of pleural disease. They concluded that pleural plaques are not an active site of /sup 67/Ga accumulation and do not contribute significantly to the thoracic uptake of the marker.

  18. The changes of relative position of the thoracic aorta after anterior or posterior instrumentation of type I Lenke curve in adolescent idiopathic thoracic scoliosis.

    PubMed

    Wang, Weijun; Zhu, Zezhang; Zhu, Feng; Wang, Bin; Chu, Winnie C W; Cheng, Jack C Y; Qiu, Yong

    2008-08-01

    The risk of impingement of the aorta associated with thoracic vertebral screw or pedicle screw instrumentation in the treatment of thoracic scoliosis has been an important concern. To understand this phenomenon more systematically, the relative position of the aorta with reference to the thoracic vertebrae in right thoracic adolescent idiopathic scoliosis (AIS) following anterior and posterior spinal instrumentation was analyzed in detail quantitatively; 34 patients underwent anterior (n = 14) or posterior (n = 20) spinal instrumentation were recruited in the present study. The relative position of the thoracic aorta, vertebral rotation, apical vertebral translation and thoracic kyphosis were measured from pre- and post-operative CT images from T5 to T12. The aorta was found to shift antero-medially in the anterior instrumentation group but not in the posterior spinal instrumentation group. It is likely that the disc removal, soft tissue release and spontaneous vertebral derotation of the scoliosis could account for the antero-medial shifting of the aorta. By the shifting, the space for contralateral screw penetration was reduced.

  19. A design of a DICOM-RT-based tool box for nonrigid 4D dose calculation.

    PubMed

    Wong, Victy Y W; Baker, Colin R; Leung, T W; Tung, Stewart Y

    2016-03-01

    The study was aimed to introduce a design of a DICOM-RT-based tool box to facilitate 4D dose calculation based on deformable voxel-dose registration. The computational structure and the calculation algorithm of the tool box were explicitly discussed in the study. The tool box was written in MATLAB in conjunction with CERR. It consists of five main functions which allow a) importation of DICOM-RT-based 3D dose plan, b) deformable image registration, c) tracking voxel doses along breathing cycle, d) presentation of temporal dose distribution at different time phase, and e) derivation of 4D dose. The efficacy of using the tool box for clinical application had been verified with nine clinical cases on retrospective-study basis. The logistic and the robustness of the tool box were tested with 27 applications and the results were shown successful with no computational errors encountered. In the study, the accumulated dose coverage as a function of planning CT taken at end-inhale, end-exhale, and mean tumor position were assessed. The results indicated that the majority of the cases (67%) achieved maximum target coverage, while the planning CT was taken at the temporal mean tumor position and 56% at the end-exhale position. The comparable results to the literature imply that the studied tool box can be reliable for 4D dose calculation. The authors suggest that, with proper application, 4D dose calculation using deformable registration can provide better dose evaluation for treatment with moving target. PACS number(s): 87.55.kh.

  20. 32 CFR 1645.4 - Exclusion from Class 4-D.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... MINISTERS OF RELIGION § 1645.4 Exclusion from Class 4-D. A registrant is excluded from Class 4-D when his... duly ordained minister of religion in accordance with the ceremonial rite or discipline of a church... principles of religion and administer the ordinances of public worship, as embodied in the creed...

  1. 32 CFR 1645.4 - Exclusion from Class 4-D.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... MINISTERS OF RELIGION § 1645.4 Exclusion from Class 4-D. A registrant is excluded from Class 4-D when his... duly ordained minister of religion in accordance with the ceremonial rite or discipline of a church... principles of religion and administer the ordinances of public worship, as embodied in the creed...

  2. 4D Printing with Mechanically Robust, Thermally Actuating Hydrogels.

    PubMed

    Bakarich, Shannon E; Gorkin, Robert; in het Panhuis, Marc; Spinks, Geoffrey M

    2015-06-01

    A smart valve is created by 4D printing of hydrogels that are both mechanically robust and thermally actuating. The printed hydrogels are made up of an interpenetrating network of alginate and poly(N-isopropylacrylamide). 4D structures are created by printing the "dynamic" hydrogel ink alongside other static materials.

  3. SU-D-17A-04: The Impact of Audiovisual Biofeedback On Image Quality During 4D Functional and Anatomic Imaging: Results of a Prospective Clinical Trial

    SciTech Connect

    Keall, P; Pollock, S; Yang, J; Diehn, M; Berger, J; Graves, E; Loo, B; Yamamoto, T

    2014-06-01

    Purpose: The ability of audiovisual (AV) biofeedback to improve breathing regularity has not previously been investigated for functional imaging studies. The purpose of this study was to investigate the impact of AV biofeedback on 4D-PET and 4D-CT image quality in a prospective clinical trial. We hypothesized that motion blurring in 4D-PET images and the number of artifacts in 4D-CT images are reduced using AV biofeedback. Methods: AV biofeedback is a real-time, interactive and personalized system designed to help a patient self-regulate his/her breathing using a patient-specific representative waveform and musical guides. In an IRB-approved prospective clinical trial, 4D-PET and 4D-CT images of 10 lung cancer patients were acquired with AV biofeedback (AV) and free breathing (FB). The 4D-PET images in 6 respiratory bins were analyzed for motion blurring by: (1) decrease of GTVPET and (2) increase of SUVmax in 4-DPET compared to 3D-PET. The 4D-CT images were analyzed for artifacts by: (1) comparing normalized cross correlation-based scores (NCCS); and (2) quantifying a visual assessment score (VAS). A two-tailed paired t-test was used to test the hypotheses. Results: The impact of AV biofeedback on 4D-PET and 4D-CT images varied widely between patients, suggesting inconsistent patient comprehension and capability. Overall, the 4D-PET decrease of GTVPET was 2.0±3.0cm3 with AV and 2.3±3.9cm{sup 3} for FB (p=0.61). The 4D-PET increase of SUVmax was 1.6±1.0 with AV and 1.1±0.8 with FB (p=0.002). The 4D-CT NCCS were 0.65±0.27 with AV and 0.60±0.32 for FB (p=0.32). The 4D-CT VAS was 0.0±2.7 (p=ns). Conclusion: A 10-patient study demonstrated a statistically significant reduction of motion blurring of AV over FB for 1/2 functional 4D-PET imaging metrics. No difference between AV and FB was found for 2 anatomic 4D-CT imaging metrics. Future studies will focus on optimizing the human-computer interface and including patient training sessions for improved

  4. 4D motion animation of coronary arteries from rotational angiography

    NASA Astrophysics Data System (ADS)

    Holub, Wolfgang; Rohkohl, Christopher; Schuldhaus, Dominik; Prümmer, Marcus; Lauritsch, Günter; Hornegger, Joachim

    2011-03-01

    Time-resolved 3-D imaging of the heart is a major research topic in the medical imaging community. Recent advances in the interventional cardiac 3-D imaging from rotational angiography (C-arm CT) are now also making 4-D imaging feasible during procedures in the catheter laboratory. State-of-the-art reconstruction algorithms try to estimate the cardiac motion and utilize the motion field to enhance the reconstruction of a stable cardiac phase (diastole). The available data offers a handful of opportunities during interventional procedures, e.g. the ECG-synchronized dynamic roadmapping or the computation and analysis of functional parameters. In this paper we will demonstrate that the motion vector field (MVF) that is output by motion compensated image reconstruction algorithms is in general not directly usable for animation and motion analysis. Dependent on the algorithm different defects are investigated. A primary issue is that the MVF needs to be inverted, i.e. the wrong direction of motion is provided. A second major issue is the non-periodicity of cardiac motion. In algorithms which compute a non-periodic motion field from a single rotation the in depth motion information along viewing direction is missing, since this cannot be measured in the projections. As a result, while the MVF improves reconstruction quality, it is insufficient for motion animation and analysis. We propose an algorithm to solve both problems, i.e. inversion and missing in-depth information in a unified framework. A periodic version of the MVF is approximated. The task is formulated as a linear optimization problem where a parametric smooth motion model based on B-splines is estimated from the MVF. It is shown that the problem can be solved using a sparse QR factorization within a clinical feasible time of less than one minute. In a phantom experiment using the publicly available CAVAREV platform, the average quality of a non-periodic animation could be increased by 39% by applying the

  5. Thoracic Radiculopathy due to Rare Causes

    PubMed Central

    2016-01-01

    Thoracic radiculopathy represents an uncommon spinal disorder that is frequently overlooked in the evaluation of thoracic, or abdominal pain syndrome. The clinical representation of this uncommon disorder is often atypical. With many differential diagnoses to consider, it is not surprising that the cause of thoracic radiculopathy is often not discovered for months, or years, after the symptoms arise. We report two rare cases of thoracic radiculopathy; one case was caused by extraskeletal Ewing sarcoma (EES) along the thoracic paraspinal area, and the other by foraminal stenosis, due to a bony spur of the thoracic vertebra. As such, thoracic radiculopathy should be considered in the diagnosis of patients with thoracic and abdominal pain, especially if initial diagnostic studies are inconclusive. PMID:27446792

  6. [A case of long thoracic nerve palsy, with winged scapula, as a result of prolonged exertion on practicing archery].

    PubMed

    Shimizu, J; Nishiyama, K; Takeda, K; Ichiba, T; Sakuta, M

    1990-08-01

    Reports of isolated long thoracic nerve palsy are rare in Japan. We reported a case of isolated long thoracic nerve palsy, resulted from recurrent injury to the nerve. Muscle CT and electrodiagnostic study were useful for confirming diagnosis of this cases. This patient was a student aged 20 years, with nothing of importance in his family or past history. After he started practicing archery, winging of left scapula was gradually developed. Physical examination revealed weakness and atrophy of left serratus anterior muscle. There was no wasting and weakness of other should girdle muscles. Hematochemical tests were normal, except slight hyperthyroidism. Radiography and myelography of the cervical spine were normal. Muscle CT of upper thoracic level demonstrated atrophy of left serratus anterior muscle, and no abnormality were found in other muscles. Electromyogram of the left serratus anterior revealed discrete activity of reduced amplitude, and fibrillation potentials and positive sharp waves. Conduction time for left long thoracic nerve was prolonged, and amplitude of the evoked response was small and there were temporal dispersion. Muscle CT and electrodiagnostic studies were suggestive of neuroapraxia of left long thoracic nerve. Over stretching or compression during exercises may be responsible for the damage to the long thoracic nerve.

  7. A set of 4D pediatric XCAT reference phantoms for multimodality research

    SciTech Connect

    Norris, Hannah Zhang, Yakun; Bond, Jason; Sturgeon, Gregory M.; Samei, E.; Segars, W. P.; Minhas, Anum; Frush, D.; Tward, Daniel J.; Ratnanather, J. T.; Miller, M. I.

    2014-03-15

    Purpose: The authors previously developed an adult population of 4D extended cardiac-torso (XCAT) phantoms for multimodality imaging research. In this work, the authors develop a reference set of 4D pediatric XCAT phantoms consisting of male and female anatomies at ages of newborn, 1, 5, 10, and 15 years. These models will serve as the foundation from which the authors will create a vast population of pediatric phantoms for optimizing pediatric CT imaging protocols. Methods: Each phantom was based on a unique set of CT data from a normal patient obtained from the Duke University database. The datasets were selected to best match the reference values for height and weight for the different ages and genders according to ICRP Publication 89. The major organs and structures were segmented from the CT data and used to create an initial pediatric model defined using nonuniform rational B-spline surfaces. The CT data covered the entire torso and part of the head. To complete the body, the authors manually added on the top of the head and the arms and legs using scaled versions of the XCAT adult models or additional models created from cadaver data. A multichannel large deformation diffeomorphic metric mapping algorithm was then used to calculate the transform from a template XCAT phantom (male or female 50th percentile adult) to the target pediatric model. The transform was applied to the template XCAT to fill in any unsegmented structures within the target phantom and to implement the 4D cardiac and respiratory models in the new anatomy. The masses of the organs in each phantom were matched to the reference values given in ICRP Publication 89. The new reference models were checked for anatomical accuracy via visual inspection. Results: The authors created a set of ten pediatric reference phantoms that have the same level of detail and functionality as the original XCAT phantom adults. Each consists of thousands of anatomical structures and includes parameterized models

  8. Graph-based retrospective 4D image construction from free-breathing MRI slice acquisitions

    NASA Astrophysics Data System (ADS)

    Tong, Yubing; Udupa, Jayaram K.; Ciesielski, Krzysztof C.; McDonough, Joseph M.; Mong, Andrew; Campbell, Robert M.

    2014-03-01

    4D or dynamic imaging of the thorax has many potential applications [1, 2]. CT and MRI offer sufficient speed to acquire motion information via 4D imaging. However they have different constraints and requirements. For both modalities both prospective and retrospective respiratory gating and tracking techniques have been developed [3, 4]. For pediatric imaging, x-ray radiation becomes a primary concern and MRI remains as the de facto choice. The pediatric subjects we deal with often suffer from extreme malformations of their chest wall, diaphragm, and/or spine, as such patient cooperation needed by some of the gating and tracking techniques are difficult to realize without causing patient discomfort. Moreover, we are interested in the mechanical function of their thorax in its natural form in tidal breathing. Therefore free-breathing MRI acquisition is the ideal modality of imaging for these patients. In our set up, for each coronal (or sagittal) slice position, slice images are acquired at a rate of about 200-300 ms/slice over several natural breathing cycles. This produces typically several thousands of slices which contain both the anatomic and dynamic information. However, it is not trivial to form a consistent and well defined 4D volume from these data. In this paper, we present a novel graph-based combinatorial optimization solution for constructing the best possible 4D scene from such data entirely in the digital domain. Our proposed method is purely image-based and does not need breath holding or any external surrogates or instruments to record respiratory motion or tidal volume. Both adult and children patients' data are used to illustrate the performance of the proposed method. Experimental results show that the reconstructed 4D scenes are smooth and consistent spatially and temporally, agreeing with known shape and motion of the lungs.

  9. The Use of Computed Tomography Attenuation to Evaluate Osteoporosis Following Acute Fractures of the Thoracic and Lumbar Vertebra

    PubMed Central

    Cagan, Amanda; Morgan, Robert; Davis, Rick; Asis, Martin; Switzer, Julie; Polly, David W.

    2014-01-01

    Background: Relatively few patients have dual-energy x-ray absorptiometry to quantify the magnitude of bone loss as they age. Recent work correlates mean computed tomography (CT) attenuation in the level I (L1) vertebra with bone mineral density (BMD), making it possible to objectively evaluate the magnitude of bone loss in osteoporosis by this method. The aims of this study were to evaluate the utility of using CT scans in patients with acute thoracic and lumbar spine fractures to diagnose osteoporosis and using CT attenuation to evaluate the association between age and BMD. Methods: We performed a retrospective study of patients with acute fractures of the thoracic or lumbar spine who had also undergone an abdominal (or L1) CT scan and compared mean CT attenuation in L1 against threshold values. We also compared differences in CT attenuation between younger (<65 years) and older (≥65 years) and older patients. Results: A total of 124 patients were evaluated (74 thoracic and 50 lumbar fractures). Overall, there was a strong correlation between age and bone density as measured by CT attenuation (r = −.76). Among those with thoracic fractures (<65 years), mean CT attenuation was 196.51 HU. Forty-one patients were ≥65 years and had mean CT attenuation of 105.90 HU (P < .001). In patients with lumbar fractures, 27 patients were <65 years and had a mean CT attenuation of 192.26 HU and 23 patients were ≥65 years and had mean CT attenuation of 114.31 HU (P < .001). At the threshold of 110 HU, set for specificity, the magnitude of difference between the age-stratified cohorts was greater in the thoracic spine (P < .0001 vs P = .003). Discussion: Using opportunistic CT, we demonstrate the relative frequency of osteoporosis in patients with acute fractures of the thoracic and lumbar spine and confirm that the association increases with age. The CT attenuation may provide a cheap and convenient method to help confirm a clinical diagnosis of osteoporosis in patients

  10. Sensitivity of Thoracic Digital Tomosynthesis (DTS) for the Identification of Lung Nodules.

    PubMed

    Langer, Steve G; Graner, Brian D; Schueler, Beth A; Fetterly, Kenneth A; Kofler, James M; Mandrekar, Jayawant N; Bartholmai, Brian J

    2016-02-01

    Thoracic computed tomography (CT) is considered the gold standard for detection lung pathology, yet its efficacy as a screening tool in regards to cost and radiation dose continues to evolve. Chest radiography (CXR) remains a useful and ubiquitous tool for detection and characterization of pulmonary pathology, but reduced sensitivity and specificity compared to CT. This prospective, blinded study compares the sensitivity of digital tomosynthesis (DTS), to that of CT and CXR for the identification and characterization of lung nodules. Ninety-five outpatients received a posteroanterior (PA) and lateral CXR, DTS, and chest CT at one care episode. The CXR and DTS studies were independently interpreted by three thoracic radiologists. The CT studies were used as the gold standard and read by a fourth thoracic radiologist. Nodules were characterized by presence, location, size, and composition. The agreement between observers and the effective radiation dose for each modality was objectively calculated. One hundred forty-five nodules of greatest diameter larger than 4 mm and 215 nodules less than 4 mm were identified by CT. DTS identified significantly more >4 mm nodules than CXR (DTS 32 % vs. CXR 17 %). CXR and DTS showed no significant difference in the ability to identify the smaller nodules or central nodules within 3 cm of the hilum. DTS outperformed CXR in identifying pleural nodules and those nodules located greater than 3 cm from the hilum. Average radiation dose for CXR, DTS, and CT were 0.10, 0.21, and 6.8 mSv, respectively. Thoracic digital tomosynthesis requires significantly less radiation dose than CT and nearly doubles the sensitivity of that of CXR for the identification of lung nodules greater than 4 mm. However, sensitivity and specificity for detection and characterization of lung nodules remains substantially less than CT. The apparent benefits over CXR, low cost, rapid acquisition, and minimal radiation dose of thoracic DTS suggest that it may be a

  11. Helical CT in emergency radiology.

    PubMed

    Novelline, R A; Rhea, J T; Rao, P M; Stuk, J L

    1999-11-01

    Today, a wide range of traumatic and nontraumatic emergency conditions are quickly and accurately diagnosed with helical computed tomography (CT). Many traditional emergency imaging procedures have been replaced with newer helical CT techniques that can be performed in less time and with greater accuracy, less patient discomfort, and decreased cost. The speed of helical technology permits CT examination of seriously ill patients in the emergency department, as well as patients who might not have been taken to CT previously because of the length of the examinations of the past. Also, helical technology permits multiple, sequential CT scans to be quickly obtained in the same patient, a great advance for the multiple-trauma patient. Higher quality CT examinations result from decreased respiratory misregistration, enhanced intravenous contrast material opacification of vascular structures and parenchymal organs, greater flexibility in image reconstruction, and improved multiplanar and three-dimensional reformations. This report summarizes the role and recommended protocols for the helical CT diagnosis of thoracic aortic trauma; aortic dissection; pulmonary embolism; acute conditions of the neck soft tissues; abdominal trauma; urinary tract stones; appendicitis; diverticulitis; abdominal aortic aneurysm; fractures of the face, spine, and extremities; and acute stroke.

  12. Experimental validation of a 4D elastic registration algorithm.

    PubMed

    Leung, Corina; Hashtrudi-Zaad, Keyvan; Foroughi, Pezhman; Abolmaesumi, Purang

    2008-01-01

    This paper presents an extensive validation study of an elastic registration algorithm for dynamic 3D ultrasound images (also known as a 4D image). The registration algorithm uses attribute vectors from both a fixed and previous moving images to perform feature-based alignment of a series of images. The 4D method reduces computational requirements and increases the effective search space for the location of corresponding features, resulting in enhanced registration speed when compared to a static 3D registration technique. Experimental analysis revealed up to 32% improvement in speed when using the 4D method, which makes the algorithm attractive for real-time applications.

  13. Spinal dermoid sinus in a Dachshund with vertebral and thoracic limb malformations

    PubMed Central

    2014-01-01

    Background Dermoid sinus is an uncommon epithelial-lined fistula that may be associated with vertebral malformations. In humans, Klippel-Feil syndrome (KFS) is a rare condition characterized by congenital cervical vertebral fusion and may be associated with other developmental defects, including dermoid sinus. The present case report describes an adult Dachshund with cervical and cranial thoracic vertebral malformations as well as thoracic limb malformations resembling KFS with a concurrent type IV dermoid sinus. Case presentation A 1.5 year-old Dachshund with congenital thoracic limbs deformities and cervical-thoracic vertebral malformations presented with cervical hyperesthesia, rigidity of the cervical musculature and tetraparesis. Neurologic, radiographic, and computed tomography (CT) (2D, 3D, CT fistulography) examinations revealed skeletal anomalies, a dermoid sinus in the cranial thoracic region and epidural gas within the vertebral canal. Surgical resection and histopathological evaluation of the sinus tract were performed and confirmed a type IV dermoid sinus. The clinical signs progressively recovered postoperatively, and no recurrent signs were observed after 6 months of follow-up. Conclusions Cervical vertebral malformations associated with limbs anomalies have not been reported in dogs and may represent a condition similar to KFS in humans. KFS can occur concurrently with other congenital conditions including dermoid sinus and should be included among the complex congenital anomalies described in dogs. PMID:24593884

  14. Volumetric limiting spatial resolution analysis of four dimensional digital subtraction angiography (4D-DSA)

    NASA Astrophysics Data System (ADS)

    Davis, Brian; Oberstar, Erick; Royalty, Kevin; Schafer, Sebastian; Strother, Charles; Mistretta, Charles

    2015-03-01

    Static C-Arm CT 3D FDK baseline reconstructions (3D-DSA) are unable to provide temporal information to radiologists. 4D-DSA provides a time series of 3D volumes implementing a constrained image, thresholded 3D-DSA, reconstruction utilizing temporal dynamics in the 2D projections. Volumetric limiting spatial resolution (VLSR) of 4DDSA is quantified and compared to a 3D-DSA reconstruction using the same 3D-DSA parameters. Investigated were the effects of varying over significant ranges the 4D-DSA parameters of 2D blurring kernel size applied to the projection and threshold applied to the 3D-DSA when generating the constraining image of a scanned phantom (SPH) and an electronic phantom (EPH). The SPH consisted of a 76 micron tungsten wire encased in a 47 mm O.D. plastic radially concentric thin walled support structure. An 8-second/248-frame/198° scan protocol acquired the raw projection data. VLSR was determined from averaged MTF curves generated from each 2D transverse slice of every (248) 4D temporal frame (3D). 4D results for SPH and EPH were compared to the 3D-DSA. Analysis of the 3D-DSA resulted in a VLSR of 2.28 and 1.69 lp/mm for the EPH and SPH respectively. Kernel (2D) sizes of either 10x10 or 20x20 pixels with a threshold of 10% of the 3D-DSA as a constraining image provided 4D-DSA VLSR nearest to the 3D-DSA. 4D-DSA algorithms yielded 2.21 and 1.67 lp/mm with a percent error of 3.1% and 1.2% for the EPH and SPH respectively as compared to the 3D-DSA. This research indicates 4D-DSA is capable of retaining the resolution of the 3D-DSA.

  15. [Japanese Board Certified Thoracic Surgeon].

    PubMed

    Chihara, Koji

    2017-01-01

    The Japanese Board of General Thoracic Surgery (JBGTS) consisted by Japanese Association of Chest Surgery (JACS) and The Japanese Association of Thoracic Surgery (JATS) has been certified Japanese Board Certified Thoracic Surgeon (JBCTS) since 2004. At present, JBCTS is obtained by being of Certified Surgeon by Japan Surgical Society( JSS), completion of minimum requirement of surgical experience, scientific papers, presentation at medical assembly, learning of postgraduate educational programs, and examination approximate 11 years after graduation of medical school. Thirteen hundreds JBCTS throughout Japan are engaged in operation for 77,000 cases/year, including 38,000 lung cancer patients/year. The operative volume has been growing lineally these 30 years, and operative mortality in lung cancer patients has been less than 1% these several years. Japanese Medical Specialty Board (JMSB) published a guideline of the new system of medical specialty certification system in Jury 2014, in which fundamental structure is consisted by basic specialties of 19 medical fields and following subspecialties and program based system rather than curriculum based system. According to this guideline, JBGTS has been collaborated with JSS in order to establish sequential programs of the 2 specialties, and proposed an improved certification system to accomplish the mission that it educates trainees to be thoracic surgical professionals who is able to perform safe and standalized procedures.

  16. Aneurysms of the thoracic aorta

    PubMed Central

    Le Roux, B. T.; Rogers, M. A.; Gotsman, M. S.

    1971-01-01

    Selected radiographs from 40 patients with thoracic aortic aneurysm serve to illustrate most of the radiographic features of this disease. Surgical techniques are outlined and were used to modify the natural course of the disease in 14 patients, with three postoperative deaths. The remaining 26 patients were either moribund on admission and died shortly afterwards or declined operations and died later. Images PMID:5144643

  17. Fishbone penetration of the thoracic esophagus with prolonged asymptomatic impaction within the aorta.

    PubMed

    Ko, Sheung-Fat; Lu, Hung-I; Ng, Shu-Hang; Kung, Chia-Te

    2013-02-01

    A 54-year-old man with fishbone penetration of the thoracic esophagus and mediastinal hematoma was successfully managed with conservative treatment. Six-month follow-up computed tomography (CT) revealed migration of the fishbone into the aorta; however, the patient was asymptomatic and refused surgery. Six years later, CT showed persistent impaction of the fishbone within the aorta, but the patient was healthy. To our knowledge, this is the first reported case of serial CT documentation of fishbone penetration of the esophagus with migration into and prolonged asymptomatic impaction within the aorta.

  18. SU-E-T-222: Computational Optimization of Monte Carlo Simulation On 4D Treatment Planning Using the Cloud Computing Technology

    SciTech Connect

    Chow, J

    2015-06-15

    Purpose: This study evaluated the efficiency of 4D lung radiation treatment planning using Monte Carlo simulation on the cloud. The EGSnrc Monte Carlo code was used in dose calculation on the 4D-CT image set. Methods: 4D lung radiation treatment plan was created by the DOSCTP linked to the cloud, based on the Amazon elastic compute cloud platform. Dose calculation was carried out by Monte Carlo simulation on the 4D-CT image set on the cloud, and results were sent to the FFD4D image deformation program for dose reconstruction. The dependence of computing time for treatment plan on the number of compute node was optimized with variations of the number of CT image set in the breathing cycle and dose reconstruction time of the FFD4D. Results: It is found that the dependence of computing time on the number of compute node was affected by the diminishing return of the number of node used in Monte Carlo simulation. Moreover, the performance of the 4D treatment planning could be optimized by using smaller than 10 compute nodes on the cloud. The effects of the number of image set and dose reconstruction time on the dependence of computing time on the number of node were not significant, as more than 15 compute nodes were used in Monte Carlo simulations. Conclusion: The issue of long computing time in 4D treatment plan, requiring Monte Carlo dose calculations in all CT image sets in the breathing cycle, can be solved using the cloud computing technology. It is concluded that the optimized number of compute node selected in simulation should be between 5 and 15, as the dependence of computing time on the number of node is significant.

  19. Emergency Thoracic US: The Essentials.

    PubMed

    Wongwaisayawan, Sirote; Suwannanon, Ruedeekorn; Sawatmongkorngul, Sorravit; Kaewlai, Rathachai

    2016-01-01

    Acute thoracic symptoms are common among adults visiting emergency departments in the United States. Adults with these symptoms constitute a large burden on the overall resources used in the emergency department. The wide range of possible causes can make a definitive diagnosis challenging, even after clinical evaluation and initial laboratory testing. In addition to radiography and computed tomography, thoracic ultrasonography (US) is an alternative imaging modality that can be readily performed in real time at the patient's bedside to help diagnose many thoracic diseases manifesting acutely and in the trauma setting. Advantages of US include availability, relatively low cost, and lack of ionizing radiation. Emergency thoracic US consists of two main parts, lung and pleura US and focused cardiac US, which are closely related. Acoustic mismatches among aerated lungs, pleura, chest wall, and pathologic conditions produce artifacts useful for diagnosis of pneumothorax and pulmonary edema and help in detection of subpleural, pleural, and chest wall pathologic conditions such as pneumonia, pleural effusion, and fractures. Visual assessment of cardiac contractility and detection of right ventricular dilatation and pericardial effusion at focused cardiac US are critical in patients presenting with acute dyspnea and trauma. Additional US examinations of the inferior vena cava for noninvasive volume assessment and of the groin areas for detection of deep venous thrombosis are often performed at the same time. This multiorgan US approach can provide valuable information for emergency treatment of both traumatic and nontraumatic thoracic diseases involving the lungs, pleura, chest wall, heart, and vascular system. Online supplemental material is available for this article. (©)RSNA, 2016.

  20. Effect of thoracic arthrodesis in prepubertal New Zealand white rabbits on cardio-pulmonary function

    PubMed Central

    Canavese, Federico; Dimeglio, Alain; Barbetta, Davide; Pereira, Bruno; Fabbro, Sergio; Bassini, Federica; Canavese, Bartolomeo

    2014-01-01

    Background: This experimental study was aimed at evaluating the type of cardiac and pulmonary involvement, in relation to changes of the thoracic spine and cage in prepubertal rabbits with nondeformed spine following dorsal arthrodesis. The hypothesis was that T1-T12 arthrodesis modified thoracic dimensions, but would not modify cardiopulmonary function once skeletal maturity was reached. Materials and Methods: The study was conducted in 16 female New Zealand White (NZW) rabbits. Nine rabbits were subjected to T1-T12 dorsal arthrodesis while seven were sham-operated. Echocardiographic images were obtained at 12 months after surgery and parameters for 2-dimensional and M-mode echocardiographic variables were assessed. One week before echocardiographic examination, blood samples were withdrawn from the animals’ central artery of the left ear to obtain blood gas values. One week after echocardiographic assessment, a thoracic CT scan was performed under general anesthesia. Chest depth (CD) and width (CW), thoracic kyphosis (ThK) and sternal length (StL) were measured; thoracic index (ThI), expressed as CD/CW ratio. All subjects were euthanized after the CT scan. Heart and lungs were subsequently removed to measure weight and volume. Results: The values for 2-dimensional and M-mode echocardiographic variables were found to be uniformly and significantly higher, compared to those reported in anesthetized rabbits. CD, ThK, and StL were considerably lower in operated rabbits, as compared to the ones that were sham-operated. Similarly, the ThI was lower in operated rabbits than in sham-operated ones. Conclusion: Irregularities in thoracic cage growth resulting from thoracic spine arthrodesis did not alter blood and echocardiographic parameters in NZW rabbits. PMID:24741141

  1. Substitutional 4d and 5d impurities in graphene.

    PubMed

    Alonso-Lanza, Tomás; Ayuela, Andrés; Aguilera-Granja, Faustino

    2016-08-21

    We describe the structural and electronic properties of graphene doped with substitutional impurities of 4d and 5d transition metals. The adsorption energies and distances for 4d and 5d metals in graphene show similar trends for the later groups in the periodic table, which are also well-known characteristics of 3d elements. However, along earlier groups the 4d impurities in graphene show very similar adsorption energies, distances and magnetic moments to the 5d ones, which can be related to the influence of the 4d and 5d lanthanide contraction. Surprisingly, within the manganese group, the total magnetic moment of 3 μB for manganese is reduced to 1 μB for technetium and rhenium. We find that compared with 3d elements, the larger size of the 4d and 5d elements causes a high degree of hybridization with the neighbouring carbon atoms, reducing spin splitting in the d levels. It seems that the magnetic adjustment of graphene could be significantly different if 4d or 5d impurities are used instead of 3d impurities.

  2. 4D offline PET-based treatment verification in scanned ion beam therapy: a phantom study

    NASA Astrophysics Data System (ADS)

    Kurz, Christopher; Bauer, Julia; Unholtz, Daniel; Richter, Daniel; Stützer, Kristin; Bert, Christoph; Parodi, Katia

    2015-08-01

    At the Heidelberg Ion-Beam Therapy Center, patient irradiation with scanned proton and carbon ion beams is verified by offline positron emission tomography (PET) imaging: the {β+} -activity measured within the patient is compared to a prediction calculated on the basis of the treatment planning data in order to identify potential delivery errors. Currently, this monitoring technique is limited to the treatment of static target structures. However, intra-fractional organ motion imposes considerable additional challenges to scanned ion beam radiotherapy. In this work, the feasibility and potential of time-resolved (4D) offline PET-based treatment verification with a commercial full-ring PET/CT (x-ray computed tomography) device are investigated for the first time, based on an experimental campaign with moving phantoms. Motion was monitored during the gated beam delivery as well as the subsequent PET acquisition and was taken into account in the corresponding 4D Monte-Carlo simulations and data evaluation. Under the given experimental conditions, millimeter agreement between the prediction and measurement was found. Dosimetric consequences due to the phantom motion could be reliably identified. The agreement between PET measurement and prediction in the presence of motion was found to be similar as in static reference measurements, thus demonstrating the potential of 4D PET-based treatment verification for future clinical applications.

  3. Automatic detection of lung vessel bifurcation in thoracic CT images

    NASA Astrophysics Data System (ADS)

    Maduskar, Pragnya; Vikal, Siddharth; Devarakota, Pandu

    2011-03-01

    Computer-aided diagnosis (CAD) systems for detection of lung nodules have been an active topic of research for last few years. It is desirable that a CAD system should generate very low false positives (FPs) while maintaining high sensitivity. This work aims to reduce the number of false positives occurring at vessel bifurcation point. FPs occur quite frequently on vessel branching point due to its shape which can appear locally spherical due to the intrinsic geometry of intersecting tubular vessel structures combined with partial volume effects and soft tissue attenuation appearance surrounded by parenchyma. We propose a model-based technique for detection of vessel branching points using skeletonization, followed by branch-point analysis. First we perform vessel structure enhancement using a multi-scale Hessian filter to accurately segment tubular structures of various sizes followed by thresholding to get binary vessel structure segmentation [6]. A modified Reebgraph [7] is applied next to extract the critical points of structure and these are joined by a nearest neighbor criterion to obtain complete skeletal model of vessel structure. Finally, the skeletal model is traversed to identify branch points, and extract metrics including individual branch length, number of branches and angle between various branches. Results on 80 sub-volumes consisting of 60 actual vessel-branching and 20 solitary solid nodules show that the algorithm identified correctly vessel branching points for 57 sub-volumes (95% sensitivity) and misclassified 2 nodules as vessel branch. Thus, this technique has potential in explicit identification of vessel branching points for general vessel analysis, and could be useful in false positive reduction in a lung CAD system.

  4. 4D cone beam CT-based dose assessment for SBRT lung cancer treatment

    NASA Astrophysics Data System (ADS)

    Cai, Weixing; Dhou, Salam; Cifter, Fulya; Myronakis, Marios; Hurwitz, Martina H.; Williams, Christopher L.; Berbeco, Ross I.; Seco, Joao; Lewis, John H.

    2016-01-01

    The purpose of this research is to develop a 4DCBCT-based dose assessment method for calculating actual delivered dose for patients with significant respiratory motion or anatomical changes during the course of SBRT. To address the limitation of 4DCT-based dose assessment, we propose to calculate the delivered dose using time-varying (‘fluoroscopic’) 3D patient images generated from a 4DCBCT-based motion model. The method includes four steps: (1) before each treatment, 4DCBCT data is acquired with the patient in treatment position, based on which a patient-specific motion model is created using a principal components analysis algorithm. (2) During treatment, 2D time-varying kV projection images are continuously acquired, from which time-varying ‘fluoroscopic’ 3D images of the patient are reconstructed using the motion model. (3) Lateral truncation artifacts are corrected using planning 4DCT images. (4) The 3D dose distribution is computed for each timepoint in the set of 3D fluoroscopic images, from which the total effective 3D delivered dose is calculated by accumulating deformed dose distributions. This approach is validated using six modified XCAT phantoms with lung tumors and different respiratory motions derived from patient data. The estimated doses are compared to that calculated using ground-truth XCAT phantoms. For each XCAT phantom, the calculated delivered tumor dose values generally follow the same trend as that of the ground truth and at most timepoints the difference is less than 5%. For the overall delivered dose, the normalized error of calculated 3D dose distribution is generally less than 3% and the tumor D95 error is less than 1.5%. XCAT phantom studies indicate the potential of the proposed method to accurately estimate 3D tumor dose distributions for SBRT lung treatment based on 4DCBCT imaging and motion modeling. Further research is necessary to investigate its performance for clinical patient data.

  5. Motion-aware temporal regularization for improved 4D cone-beam computed tomography

    NASA Astrophysics Data System (ADS)

    Mory, Cyril; Janssens, Guillaume; Rit, Simon

    2016-09-01

    Four-dimensional cone-beam computed tomography (4D-CBCT) of the free-breathing thorax is a valuable tool in image-guided radiation therapy of the thorax and the upper abdomen. It allows the determination of the position of a tumor throughout the breathing cycle, while only its mean position can be extracted from three-dimensional CBCT. The classical approaches are not fully satisfactory: respiration-correlated methods allow one to accurately locate high-contrast structures in any frame, but contain strong streak artifacts unless the acquisition is significantly slowed down. Motion-compensated methods can yield streak-free, but static, reconstructions. This work proposes a 4D-CBCT method that can be seen as a trade-off between respiration-correlated and motion-compensated reconstruction. It builds upon the existing reconstruction using spatial and temporal regularization (ROOSTER) and is called motion-aware ROOSTER (MA-ROOSTER). It performs temporal regularization along curved trajectories, following the motion estimated on a prior 4D CT scan. MA-ROOSTER does not involve motion-compensated forward and back projections: the input motion is used only during temporal regularization. MA-ROOSTER is compared to ROOSTER, motion-compensated Feldkamp-Davis-Kress (MC-FDK), and two respiration-correlated methods, on CBCT acquisitions of one physical phantom and two patients. It yields streak-free reconstructions, visually similar to MC-FDK, and robust information on tumor location throughout the breathing cycle. MA-ROOSTER also allows a variation of the lung tissue density during the breathing cycle, similar to that of planning CT, which is required for quantitative post-processing.

  6. Oscillator strengths and branching fractions of 4d75p-4d75s Rh II transitions

    NASA Astrophysics Data System (ADS)

    Bouazza, Safa

    2017-01-01

    This work reports semi-empirical determination of oscillator strengths, transition probabilities and branching fractions for Rh II 4d75p-4d75s transitions in a wide wavelength range. The angular coefficients of the transition matrix, beforehand obtained in pure SL coupling with help of Racah algebra are transformed into intermediate coupling using eigenvector amplitudes of these two configuration levels determined for this purpose; The transition integral was treated as free parameter in the least squares fit to experimental oscillator strength (gf) values found in literature. The extracted value: <4d75s|r1|4d75p> =2.7426 ± 0.0007 is slightly smaller than that computed by means of ab-initio method. Subsequently to oscillator strength evaluations, transition probabilities and branching fractions were deduced and compared to those obtained experimentally or through another approach like pseudo-relativistic Hartree-Fock model including core-polarization effects.

  7. Emergency thoracic ultrasound and clinical risk management

    PubMed Central

    Interrigi, Maria Concetta; Trovato, Francesca M; Catalano, Daniela; Trovato, Guglielmo M

    2017-01-01

    Purpose Thoracic ultrasound (TUS) has been proposed as an easy-option replacement for chest X-ray (CXR) in emergency diagnosis of pneumonia, pleural effusion, and pneumothorax. We investigated CXR unforeseen diagnosis, subsequently investigated by TUS, considering its usefulness in clinical risk assessment and management and also assessing the sustainability of telementoring. Patients and methods This observational report includes a period of 6 months with proactive concurrent adjunctive TUS diagnosis telementoring, which was done using freely available smartphone applications for transfer of images and movies. Results Three hundred and seventy emergency TUS scans (excluding trauma patients) were performed and telementored. In 310 cases, no significant chest pathology was detected either by CXR, TUS, or the subsequent work-up; in 24 patients, there was full concordance between TUS and CXR (ten isolated pleural effusion; eleven pleural effusion with lung consolidations; and three lung consolidation without pleural effusion); in ten patients with lung consolidations, abnormalities identified by CXR were not detected by TUS. In 26 patients, only TUS diagnosis criteria of disease were present: in 19 patients, CXR was not diagnostic, ie, substantially negative, but TUS detected these conditions correctly, and these were later confirmed by computed tomography (CT). In seven patients, even if chest disease was identified by CXR, such diagnoses were significantly modified by ultrasound, and CT confirmed that TUS was more appropriate. The overall respective individual performances of CXR and TUS for the diagnosis of a pleural–pulmonary disease in emergency are good, with accuracy >95%. Conclusion About 20% of pneumonia cases were detectable only by CXR and 20% only by TUS and not by CXR; ie, about 40% of patients may have been misdiagnosed if, by chance, only one of the two tools had been used. The concurrent use of TUS and CXR increases the overall sensitivity and

  8. Application of adaptive kinetic modelling for bias propagation reduction in direct 4D image reconstruction.

    PubMed

    Kotasidis, F A; Matthews, J C; Reader, A J; Angelis, G I; Zaidi, H

    2014-10-21

    Parametric imaging in thoracic and abdominal PET can provide additional parameters more relevant to the pathophysiology of the system under study. However, dynamic data in the body are noisy due to the limiting counting statistics leading to suboptimal kinetic parameter estimates. Direct 4D image reconstruction algorithms can potentially improve kinetic parameter precision and accuracy in dynamic PET body imaging. However, construction of a common kinetic model is not always feasible and in contrast to post-reconstruction kinetic analysis, errors in poorly modelled regions may spatially propagate to regions which are well modelled. To reduce error propagation from erroneous model fits, we implement and evaluate a new approach to direct parameter estimation by incorporating a recently proposed kinetic modelling strategy within a direct 4D image reconstruction framework. The algorithm uses a secondary more general model to allow a less constrained model fit in regions where the kinetic model does not accurately describe the underlying kinetics. A portion of the residuals then is adaptively included back into the image whilst preserving the primary model characteristics in other well modelled regions using a penalty term that trades off the models. Using fully 4D simulations based on dynamic [(15)O]H2O datasets, we demonstrate reduction in propagation-related bias for all kinetic parameters. Under noisy conditions, reductions in bias due to propagation are obtained at the cost of increased noise, which in turn results in increased bias and variance of the kinetic parameters. This trade-off reflects the challenge of separating the residuals arising from poor kinetic modelling fits from the residuals arising purely from noise. Nonetheless, the overall root mean square error is reduced in most regions and parameters. Using the adaptive 4D image reconstruction improved model fits can be obtained in poorly modelled regions, leading to reduced errors potentially propagating

  9. Semaphorin 4D Promotes Skeletal Metastasis in Breast Cancer

    PubMed Central

    Yang, Ying-Hua; Buhamrah, Asma; Schneider, Abraham; Lin, Yi-Ling; Zhou, Hua; Bugshan, Amr; Basile, John R.

    2016-01-01

    Bone density is controlled by interactions between osteoclasts, which resorb bone, and osteoblasts, which deposit it. The semaphorins and their receptors, the plexins, originally shown to function in the immune system and to provide chemotactic cues for axon guidance, are now known to play a role in this process as well. Emerging data have identified Semaphorin 4D (Sema4D) as a product of osteoclasts acting through its receptor Plexin-B1 on osteoblasts to inhibit their function, tipping the balance of bone homeostasis in favor of resorption. Breast cancers and other epithelial malignancies overexpress Sema4D, so we theorized that tumor cells could be exploiting this pathway to establish lytic skeletal metastases. Here, we use measurements of osteoblast and osteoclast differentiation and function in vitro and a mouse model of skeletal metastasis to demonstrate that both soluble Sema4D and protein produced by the breast cancer cell line MDA-MB-231 inhibits differentiation of MC3T3 cells, an osteoblast cell line, and their ability to form mineralized tissues, while Sema4D-mediated induction of IL-8 and LIX/CXCL5, the murine homologue of IL-8, increases osteoclast numbers and activity. We also observe a decrease in the number of bone metastases in mice injected with MDA-MB-231 cells when Sema4D is silenced by RNA interference. These results are significant because treatments directed at suppression of skeletal metastases in bone-homing malignancies usually work by arresting bone remodeling, potentially leading to skeletal fragility, a significant problem in patient management. Targeting Sema4D in these cancers would not affect bone remodeling and therefore could elicit an improved therapeutic result without the debilitating side effects. PMID:26910109

  10. Soil matrix and macropore biodegradation of 2,4-D

    SciTech Connect

    Pivetz, B.E.; Steenhuis, T.S.

    1995-07-01

    Preferential flow of pesticides in macropores can lead to decreased travel times through the vadose zone and increased groundwater contamination. Macropores, however, may present a favorable environment for biodegradation because of greater oxygen, nutrient, and substrate supply, and higher microbial populations in earthworm burrows, compared to the soil matrix. The biodegradation of 2,4-dichlorophenoxyacetic acid (2,4-D) was measured in macropores and soil matrix of packed soil columns (7.0-cm diam., 10-cm length) and undisturbed cores contained as well-defined artificial macropore and the undisturbed cores contained earthworm-burrow macropores. A 50 {mu}g/L 2,4-D solution was continuously applied to the unsaturated soil surface and breakthrough curves (BTCs) indicating pesticide loss in the effluent were obtained from the soil matrix and macropore flow paths. Biodegradation rates were calculated separately for each flow path by comparing the BTCs to BTCs representing abiotic conditions, and dividing the 2,4-D loss by the travel time through each flow path. The biodegradation rates increased with time in both flow paths, and the final biodegradation rate in the macropore region surpassed that of the matrix, presumably because of increased microbial populations in the macropore. Complete loss of the 2,4-D in both flow paths was observed after continuous application of 2,4-D for 400 h, with maximum column-averaged 2,4-D loss rates of 0.879 {mu}g/(L h) in the matrix and 1.073 {mu}g/(L h) in the macropore. Biodegradation of 2,4-D was also observed in the macropore and matrix regions of the undisturbed soil cores. 19 refs., 7 figs., 2 tabs.

  11. Semaphorin 4D Promotes Skeletal Metastasis in Breast Cancer.

    PubMed

    Yang, Ying-Hua; Buhamrah, Asma; Schneider, Abraham; Lin, Yi-Ling; Zhou, Hua; Bugshan, Amr; Basile, John R

    2016-01-01

    Bone density is controlled by interactions between osteoclasts, which resorb bone, and osteoblasts, which deposit it. The semaphorins and their receptors, the plexins, originally shown to function in the immune system and to provide chemotactic cues for axon guidance, are now known to play a role in this process as well. Emerging data have identified Semaphorin 4D (Sema4D) as a product of osteoclasts acting through its receptor Plexin-B1 on osteoblasts to inhibit their function, tipping the balance of bone homeostasis in favor of resorption. Breast cancers and other epithelial malignancies overexpress Sema4D, so we theorized that tumor cells could be exploiting this pathway to establish lytic skeletal metastases. Here, we use measurements of osteoblast and osteoclast differentiation and function in vitro and a mouse model of skeletal metastasis to demonstrate that both soluble Sema4D and protein produced by the breast cancer cell line MDA-MB-231 inhibits differentiation of MC3T3 cells, an osteoblast cell line, and their ability to form mineralized tissues, while Sema4D-mediated induction of IL-8 and LIX/CXCL5, the murine homologue of IL-8, increases osteoclast numbers and activity. We also observe a decrease in the number of bone metastases in mice injected with MDA-MB-231 cells when Sema4D is silenced by RNA interference. These results are significant because treatments directed at suppression of skeletal metastases in bone-homing malignancies usually work by arresting bone remodeling, potentially leading to skeletal fragility, a significant problem in patient management. Targeting Sema4D in these cancers would not affect bone remodeling and therefore could elicit an improved therapeutic result without the debilitating side effects.

  12. A technique for estimating 4D-CBCT using prior knowledge and limited-angle projections

    SciTech Connect

    Zhang, You; Yin, Fang-Fang; Ren, Lei; Segars, W. Paul

    2013-12-15

    Purpose: To develop a technique to estimate onboard 4D-CBCT using prior information and limited-angle projections for potential 4D target verification of lung radiotherapy.Methods: Each phase of onboard 4D-CBCT is considered as a deformation from one selected phase (prior volume) of the planning 4D-CT. The deformation field maps (DFMs) are solved using a motion modeling and free-form deformation (MM-FD) technique. In the MM-FD technique, the DFMs are estimated using a motion model which is extracted from planning 4D-CT based on principal component analysis (PCA). The motion model parameters are optimized by matching the digitally reconstructed radiographs of the deformed volumes to the limited-angle onboard projections (data fidelity constraint). Afterward, the estimated DFMs are fine-tuned using a FD model based on data fidelity constraint and deformation energy minimization. The 4D digital extended-cardiac-torso phantom was used to evaluate the MM-FD technique. A lung patient with a 30 mm diameter lesion was simulated with various anatomical and respirational changes from planning 4D-CT to onboard volume, including changes of respiration amplitude, lesion size and lesion average-position, and phase shift between lesion and body respiratory cycle. The lesions were contoured in both the estimated and “ground-truth” onboard 4D-CBCT for comparison. 3D volume percentage-difference (VPD) and center-of-mass shift (COMS) were calculated to evaluate the estimation accuracy of three techniques: MM-FD, MM-only, and FD-only. Different onboard projection acquisition scenarios and projection noise levels were simulated to investigate their effects on the estimation accuracy.Results: For all simulated patient and projection acquisition scenarios, the mean VPD (±S.D.)/COMS (±S.D.) between lesions in prior images and “ground-truth” onboard images were 136.11% (±42.76%)/15.5 mm (±3.9 mm). Using orthogonal-view 15°-each scan angle, the mean VPD/COMS between the lesion

  13. Use of radiography in combination with computed tomography for the assessment of noncardiac thoracic disease in the dog and cat.

    PubMed

    Prather, Andrew B; Berry, Clifford R; Thrall, Donald E

    2005-01-01

    Computed tomography (CT) of the thorax was performed in 28 dogs and five cats and findings were compared with previous thoracic radiographs. The sample population included all animals that had thoracic radiographs and a CT study within 5 days of each other, where the complete imaging studies were available for review. Thoracic radiographs were considered indeterminate in 31 patients and CT examinations were done to acquire additional information. The presence of additional information from CT relating to presence of pathology, location of pathology, extent of pathology, and involvement of mediastinal structures was recorded. Whether there was a change in diagnosis based on the CT findings was also recorded. In only 4/33 animals (all dogs) did CT fail to provide any new information for the parameters evaluated when compared with survey thoracic radiographs. Additional information about the pathology that was present was gained by CT in 5/5 cats and 21/ 28 dogs. New information on compartmental location of pathology was seen in 4/5 cats and 19/28 dogs. New information on pathology extent was noted in 5/5 cats and 20/28 dogs. Additional information regarding involvement of mediastinal structures was obtained in 2/5 cats and 10/28 dogs. A change in diagnosis was made in 3/5 cats and 13/28 dogs. In conclusion, CT is a valuable tool for evaluating intrathoracic disease. CT provides additional cross-sectional anatomic information that can aid in anatomic localization and evaluation of the extent of the pathology in question.

  14. CT Scans

    MedlinePlus

    ... cross-sectional pictures of your body. Doctors use CT scans to look for Broken bones Cancers Blood clots Signs of heart disease Internal bleeding During a CT scan, you lie still on a table. The table ...

  15. Improving the Diagnostic Specificity of CT for Early Detection of Lung Cancer: 4D CT-Based Pulmonary Nodule Elastometry

    DTIC Science & Technology

    2015-10-01

    A549 and SK-MES-1 cells from American Tissue Culture Collection (ATCC), carbon nanotubes (catalogue number 900–1501, lot GS1801), SES research...Houston, TX) and necessary culturing media. (Dr. Maxim, months 1-3) 2b. Inoculate 15rats (Rowett nude rats) with carbon nanotubes and follow with serial...protocol and optimize software 3a. Inoculate 10 rats with orthotopic human lung cancer cells (A549, left lung) and carbon nanotubes (right lung

  16. Improving the Diagnostic Specificity of CT for Early Detection of Lung Cancer: 4D CT-Based Pulmonary Nodule Elastometry

    DTIC Science & Technology

    2013-08-01

    International Conference of Computer Assisted Radiology and Surgery (CARS); June. Berlin, Germany2007. 3. Rohr K, Stiehl HS, Sprengel R, Buzug TM...protocol for the pulmonary benign model: 8 Two parameters were considered in developing the protocol:  Implanting the benign mode (carbon...ability to distinguish malignant tissue from lung tissue Reportable Outcomes: The following abstracts have been selected for oral presentation: 1

  17. Improving the Diagnostic Specificity of CT for Early Detection of Lung Cancer: 4D CT-Based Pulmonary Nodule Elastometry

    DTIC Science & Technology

    2013-08-01

    registration with vessel bifurcations. International Conference of Computer Assisted Radiology and Surgery (CARS); June. Berlin, Germany2007. 3... Implanting the benign mode (carbon nanotubes) at an exact pre-determined site within the lung. • Demonstrate that the volume of the lesion/tumor...have been selected for oral presentation: 1. Mohammadreza Negahdar, Billy W Loo, Maximilian Diehn, Lu Tian, Dominik Fleischmann, and Peter G Maxim

  18. Scatter correction of vessel dropout behind highly attenuating structures in 4D-DSA

    NASA Astrophysics Data System (ADS)

    Hermus, James; Mistretta, Charles; Szczykutowicz, Timothy P.

    2015-03-01

    In Computed Tomographic (CT) image reconstruction for 4 dimensional digital subtraction angiography (4D-DSA), loss of vessel contrast has been observed behind highly attenuating anatomy, such as large contrast filled aneurysms. Although this typically occurs only in a limited range of projection angles, the observed contrast time course can be altered. In this work we propose an algorithm to correct for highly attenuating anatomy within the fill projection data, i.e. aneurysms. The algorithm uses a 3D-SA volume to create a correction volume that is multiplied by the 4D-DSA volume in order to correct for signal dropout within the 4D-DSA volume. The algorithm was designed to correct for highly attenuating material in the fill volume only, however with alterations to a single step of the algorithm, artifacts due to highly attenuating materials in the mask volume (i.e. dental implants) can be mitigated as well. We successfully applied our algorithm to a case of vessel dropout due to the presence of a large attenuating aneurysm. The performance was qualified visually as the affected vessel no longer dropped out on corrected 4D-DSA time frames. The correction was quantified by plotting the signal intensity along the vessel. Our analysis demonstrated our correction does not alter vessel signal values outside of the vessel dropout region but does increase the vessel values within the dropout region as expected. We have demonstrated that this correction algorithm acts to correct vessel dropout in areas with highly attenuating materials.

  19. Tumor control probability and the utility of 4D vs 3D dose calculations for stereotactic body radiotherapy for lung cancer

    SciTech Connect

    Valdes, Gilmer; Robinson, Clifford; Lee, Percy; Morel, Delphine; Low, Daniel; Iwamoto, Keisuke S.; Lamb, James M.

    2015-04-01

    Four-dimensional (4D) dose calculations for lung cancer radiotherapy have been technically feasible for a number of years but have not become standard clinical practice. The purpose of this study was to determine if clinically significant differences in tumor control probability (TCP) exist between 3D and 4D dose calculations so as to inform the decision whether 4D dose calculations should be used routinely for treatment planning. Radiotherapy plans for Stage I-II lung cancer were created for 8 patients. Clinically acceptable treatment plans were created with dose calculated on the end-exhale 4D computed tomography (CT) phase using a Monte Carlo algorithm. Dose was then projected onto the remaining 9 phases of 4D-CT using the Monte Carlo algorithm and accumulated onto the end-exhale phase using commercially available deformable registration software. The resulting dose-volume histograms (DVH) of the gross tumor volume (GTV), planning tumor volume (PTV), and PTV{sub setup} were compared according to target coverage and dose. The PTV{sub setup} was defined as a volume including the GTV and a margin for setup uncertainties but not for respiratory motion. TCPs resulting from these DVHs were estimated using a wide range of alphas, betas, and tumor cell densities. Differences of up to 5 Gy were observed between 3D and 4D calculations for a PTV with highly irregular shape. When the TCP was calculated using the resulting DVHs for fractionation schedules typically used in stereotactic body radiation therapy (SBRT), the TCP differed at most by 5% between 4D and 3D cases, and in most cases, it was by less than 1%. We conclude that 4D dose calculations are not necessary for most cases treated with SBRT, but they might be valuable for irregularly shaped target volumes. If 4D calculations are used, 4D DVHs should be evaluated on volumes that include margin for setup uncertainty but not respiratory motion.

  20. Robotic Surgery for Thoracic Disease.

    PubMed

    Yamashita, Shin-Ichi; Yoshida, Yasuhiro; Iwasaki, Akinori

    2016-01-01

    Robotic surgeries have developed in the general thoracic field over the past decade, and publications on robotic surgery outcomes have accumulated. However, controversy remains about the application of robotic surgery, with a lack of well-established evidence. Robotic surgery has several advantages such as natural movement of the surgeon's hands when manipulating the robotic arms and instruments controlled by computer-assisted systems. Most studies have reported the feasibility and safety of robotic surgery based on acceptable morbidity and mortality compared to open or video-assisted thoracic surgery (VATS). Furthermore, there are accumulated data to indicate longer operation times and shorter hospital stay in robotic surgery. However, randomized controlled trials between robotic and open or VATS procedures are needed to clarify the advantage of robotic surgery. In this review, we focused the literature about robotic surgery used to treat lung cancer and mediastinal tumor.

  1. SU-E-J-200: A Dosimetric Analysis of 3D Versus 4D Image-Based Dose Calculation for Stereotactic Body Radiation Therapy in Lung Tumors

    SciTech Connect

    Ma, M; Rouabhi, O; Flynn, R; Xia, J; Bayouth, J

    2014-06-01

    Purpose: To evaluate the dosimetric difference between 3D and 4Dweighted dose calculation using patient specific respiratory trace and deformable image registration for stereotactic body radiation therapy in lung tumors. Methods: Two dose calculation techniques, 3D and 4D-weighed dose calculation, were used for dosimetric comparison for 9 lung cancer patients. The magnitude of the tumor motion varied from 3 mm to 23 mm. Breath-hold exhale CT was used for 3D dose calculation with ITV generated from the motion observed from 4D-CT. For 4D-weighted calculation, dose of each binned CT image from the ten breathing amplitudes was first recomputed using the same planning parameters as those used in the 3D calculation. The dose distribution of each binned CT was mapped to the breath-hold CT using deformable image registration. The 4D-weighted dose was computed by summing the deformed doses with the temporal probabilities calculated from their corresponding respiratory traces. Dosimetric evaluation criteria includes lung V20, mean lung dose, and mean tumor dose. Results: Comparing with 3D calculation, lung V20, mean lung dose, and mean tumor dose using 4D-weighted dose calculation were changed by −0.67% ± 2.13%, −4.11% ± 6.94% (−0.36 Gy ± 0.87 Gy), −1.16% ± 1.36%(−0.73 Gy ± 0.85 Gy) accordingly. Conclusion: This work demonstrates that conventional 3D dose calculation method may overestimate the lung V20, MLD, and MTD. The absolute difference between 3D and 4D-weighted dose calculation in lung tumor may not be clinically significant. This research is supported by Siemens Medical Solutions USA, Inc and Iowa Center for Research By Undergraduates.

  2. Nanotechnology applications in thoracic surgery.

    PubMed

    Hofferberth, Sophie C; Grinstaff, Mark W; Colson, Yolonda L

    2016-07-01

    Nanotechnology is an emerging, rapidly evolving field with the potential to significantly impact care across the full spectrum of cancer therapy. Of note, several recent nanotechnological advances show particular promise to improve outcomes for thoracic surgical patients. A variety of nanotechnologies are described that offer possible solutions to existing challenges encountered in the detection, diagnosis and treatment of lung cancer. Nanotechnology-based imaging platforms have the ability to improve the surgical care of patients with thoracic malignancies through technological advances in intraoperative tumour localization, lymph node mapping and accuracy of tumour resection. Moreover, nanotechnology is poised to revolutionize adjuvant lung cancer therapy. Common chemotherapeutic drugs, such as paclitaxel, docetaxel and doxorubicin, are being formulated using various nanotechnologies to improve drug delivery, whereas nanoparticle (NP)-based imaging technologies can monitor the tumour microenvironment and facilitate molecularly targeted lung cancer therapy. Although early nanotechnology-based delivery systems show promise, the next frontier in lung cancer therapy is the development of 'theranostic' multifunctional NPs capable of integrating diagnosis, drug monitoring, tumour targeting and controlled drug release into various unifying platforms. This article provides an overview of key existing and emerging nanotechnology platforms that may find clinical application in thoracic surgery in the near future.

  3. Motion management with phase-adapted 4D-optimization

    NASA Astrophysics Data System (ADS)

    Nohadani, Omid; Seco, Joao; Bortfeld, Thomas

    2010-09-01

    Cancer treatment with ionizing radiation is often compromised by organ motion, in particular for lung cases. Motion uncertainties can significantly degrade an otherwise optimized treatment plan. We present a spatiotemporal optimization method, which takes into account all phases of breathing via the corresponding 4D-CTs and provides a 4D-optimal plan that can be delivered throughout all breathing phases. Monte Carlo dose calculations are employed to warrant for highest dosimetric accuracy, as pertinent to study motion effects in lung. We demonstrate the performance of this optimization method with clinical lung cancer cases and compare the outcomes to conventional gating techniques. We report significant improvements in target coverage and in healthy tissue sparing at a comparable computational expense. Furthermore, we show that the phase-adapted 4D-optimized plans are robust against irregular breathing, as opposed to gating. This technique has the potential to yield a higher delivery efficiency and a decisively shorter delivery time.

  4. 3D/4D sonography - any safety problem.

    PubMed

    Pooh, Ritsuko K; Maeda, Kazuo; Kurjak, Asim; Sen, Cihat; Ebrashy, Alaa; Adra, Abdallah; Dayyabu, Aliyu Labaran; Wataganara, Tuangsit; de Sá, Renato Augusto Moreira; Stanojevic, Milan

    2016-03-01

    Gray-scale image data are processed in 3D ultrasound by repeated scans of multiple planes within a few seconds to achieve one surface rendering image and three perpendicular plane images. The 4D image is achieved by repeating 3D images in short intervals, i.e. 3D and 4D ultrasound are based on simple B-mode images. During 3D/4D acquisition, a fetus in utero is exposed by ultrasound beam for only a few seconds, and it is as short as real-time B-mode scanning. Therefore, simple 3D imaging is as safe as a simple B-mode scan. The 4D ultrasound is also as safe as a simple B-mode scan, but the ultrasound exposure should be shorter than 30 min. The thermal index (TI) and mechanical index (MI) should both be lower than 1.0, and the ultrasound study is regulated by the Doppler ultrasound if it is combined with simple 3D or 4D ultrasound. Recently, some articles have reported the functional changes of animal fetal brain neuronal cells and liver cell apoptosis with Doppler ultrasound. We discuss cell apoptosis by ultrasound in this report. Diagnostic ultrasound safety is achieved by controlling the output pulse and continuous ultrasound waves using thermal and mechanical indices, which should be <1.0 in abdominal and transvaginal scan, pulsed Doppler, as well as 3D and 4D ultrasound. The lowest spatial peak temporal average (SPTA) intensity of the ultrasound to suppress cultured cell growth is 240 mW/cm2, below which no ultrasound effect has been reported. An ultrasound user must be trained to recognize the ultrasound bioeffects; thermal and mechanical indices, and how to reduce these when they are higher than 1.0 on the monitor display; and guide the proper use of the ultrasound under the ALARA principle, because the user is responsible for ensuring ultrasound safety.

  5. Four-dimensional magnetic resonance imaging (4D-MRI) using image-based respiratory surrogate: A feasibility study

    PubMed Central

    Cai, Jing; Chang, Zheng; Wang, Zhiheng; Paul Segars, William; Yin, Fang-Fang

    2011-01-01

    Purpose: Four-dimensional computed tomography (4D-CT) has been widely used in radiation therapy to assess patient-specific breathing motion for determining individual safety margins. However, it has two major drawbacks: low soft-tissue contrast and an excessive imaging dose to the patient. This research aimed to develop a clinically feasible four-dimensional magnetic resonance imaging (4D-MRI) technique to overcome these limitations. Methods: The proposed 4D-MRI technique was achieved by continuously acquiring axial images throughout the breathing cycle using fast 2D cine-MR imaging, and then retrospectively sorting the images by respiratory phase. The key component of the technique was the use of body area (BA) of the axial MR images as an internal respiratory surrogate to extract the breathing signal. The validation of the BA surrogate was performed using 4D-CT images of 12 cancer patients by comparing the respiratory phases determined using the BA method to those determined clinically using the Real-time position management (RPM) system. The feasibility of the 4D-MRI technique was tested on a dynamic motion phantom, the 4D extended Cardiac Torso (XCAT) digital phantom, and two healthy human subjects. Results: Respiratory phases determined from the BA matched closely to those determined from the RPM: mean (±SD) difference in phase: −3.9% (±6.4%); mean (±SD) absolute difference in phase: 10.40% (±3.3%); mean (±SD) correlation coefficient: 0.93 (±0.04). In the motion phantom study, 4D-MRI clearly showed the sinusoidal motion of the phantom; image artifacts observed were minimal to none. Motion trajectories measured from 4D-MRI and 2D cine-MRI (used as a reference) matched excellently: the mean (±SD) absolute difference in motion amplitude: −0.3 (±0.5) mm. In the 4D-XCAT phantom study, the simulated “4D-MRI” images showed good consistency with the original 4D-XCAT phantom images. The motion trajectory of the hypothesized “tumor” matched

  6. The 4-D approach to visual control of autonomous systems

    NASA Technical Reports Server (NTRS)

    Dickmanns, Ernst D.

    1994-01-01

    Development of a 4-D approach to dynamic machine vision is described. Core elements of this method are spatio-temporal models oriented towards objects and laws of perspective projection in a foward mode. Integration of multi-sensory measurement data was achieved through spatio-temporal models as invariants for object recognition. Situation assessment and long term predictions were allowed through maintenance of a symbolic 4-D image of processes involving objects. Behavioral capabilities were easily realized by state feedback and feed-foward control.

  7. 4D ultrasound imaging - ethically justifiable in India?

    PubMed

    Indiran, Venkatraman

    2017-01-01

    Four-dimensional (4D) ultrasound (real-time volume sonography), which has been used in the West since the last decade for the determination of gender as well as for bonding and entertainment of the parents, has become widely available in India in this decade. Here, I would like to discuss the ethical issues associated with 4D ultrasonography in India. These are self-referral, the use of the technology for non-medical indications, a higher possibility of the disclosure of the foetus' gender and safety concerns.

  8. Emerging Applications of Abdominal 4D Flow MRI

    PubMed Central

    Roldán-Alzate, Alejandro; Francois, Christopher J.; Wieben, Oliver; Reeder, Scott B.

    2016-01-01

    OBJECTIVE Comprehensive assessment of abdominal hemodynamics is crucial for many clinical diagnoses but is challenged by a tremendous complexity of anatomy, normal physiology, and a wide variety of pathologic abnormalities. This article introduces 4D flow MRI as a powerful technique for noninvasive assessment of the hemodynamics of abdominal vascular territories. CONCLUSION Four-dimensional flow MRI provides clinicians with a more extensive and straightforward approach to evaluate disorders that affect blood flow in the abdomen. This review presents a series of clinical cases to illustrate the utility of 4D flow MRI in the comprehensive assessment of the abdominal circulation. PMID:27187681

  9. SU-E-J-26: A Novel Technique for Markerless Self-Sorted 4D-CBCT Using Patient Motion Modeling: A Feasibility Study

    SciTech Connect

    Zhang, L; Zhang, Y; Harris, W; Yin, F; Ren, L

    2015-06-15

    Purpose: To develop an automatic markerless 4D-CBCT projection sorting technique by using a patient respiratory motion model extracted from the planning 4D-CT images. Methods: Each phase of onboard 4D-CBCT is considered as a deformation of one phase of the prior planning 4D-CT. The deformation field map (DFM) is represented as a linear combination of three major deformation patterns extracted from the planning 4D-CT using principle component analysis (PCA). The coefficients of the PCA deformation patterns are solved by matching the digitally reconstructed radiograph (DRR) of the deformed volume to the onboard projection acquired. The PCA coefficients are solved for each single projection, and are used for phase sorting. Projections at the peaks of the Z direction coefficient are sorted as phase 1 and other projections are assigned into 10 phase bins by dividing phases equally between peaks. The 4D digital extended-cardiac-torso (XCAT) phantom was used to evaluate the proposed technique. Three scenarios were simulated, with different tumor motion amplitude (3cm to 2cm), tumor spatial shift (8mm SI), and tumor body motion phase shift (2 phases) from prior to on-board images. Projections were simulated over 180 degree scan-angle for the 4D-XCAT. The percentage of accurately binned projections across entire dataset was calculated to represent the phase sorting accuracy. Results: With a changed tumor motion amplitude from 3cm to 2cm, markerless phase sorting accuracy was 100%. With a tumor phase shift of 2 phases w.r.t. body motion, the phase sorting accuracy was 100%. With a tumor spatial shift of 8mm in SI direction, phase sorting accuracy was 86.1%. Conclusion: The XCAT phantom simulation results demonstrated that it is feasible to use prior knowledge and motion modeling technique to achieve markerless 4D-CBCT phase sorting. National Institutes of Health Grant No. R01-CA184173 Varian Medical System.

  10. Intra-thoracic rheumatoid arthritis: Imaging spectrum of typical findings and treatment related complications

    PubMed Central

    Chansakul, Thanissara; Dellaripa, Paul F.; Doyle, Tracy J.; Madan, Rachna

    2015-01-01

    Non-cardiac thoracic manifestations of rheumatoid arthritis (RA) cause significant morbidity and mortality among RA patients. Essentially all anatomic compartments in the chest can be affected including the pleura, pulmonary parenchyma, airway, and vasculature. In addition, treatment-related complications and opportunistic infections are not uncommon. Accurate diagnosis of intra-thoracic disease in an RA patient can be difficult as the radiologic findings may be nonspecific and many of these conditions may coexist. This review article serves to highlight the multitude of RA-related intra-thoracic pathological processes, emphasize differential diagnosis, diagnostic conundrums and discuss how tailoring of CT imaging and image-guided biopsy plays a key role in the management of RA-related pulmonary disease. PMID:26210094

  11. Development of a model of the coronary arterial tree for the 4D XCAT phantom

    NASA Astrophysics Data System (ADS)

    Fung, George S. K.; Segars, W. Paul; Gullberg, Grant T.; Tsui, Benjamin M. W.

    2011-09-01

    A detailed three-dimensional (3D) model of the coronary artery tree with cardiac motion has great potential for applications in a wide variety of medical imaging research areas. In this work, we first developed a computer-generated 3D model of the coronary arterial tree for the heart in the extended cardiac-torso (XCAT) phantom, thereby creating a realistic computer model of the human anatomy. The coronary arterial tree model was based on two datasets: (1) a gated cardiac dual-source computed tomography (CT) angiographic dataset obtained from a normal human subject and (2) statistical morphometric data of porcine hearts. The initial proximal segments of the vasculature and the anatomical details of the boundaries of the ventricles were defined by segmenting the CT data. An iterative rule-based generation method was developed and applied to extend the coronary arterial tree beyond the initial proximal segments. The algorithm was governed by three factors: (1) statistical morphometric measurements of the connectivity, lengths and diameters of the arterial segments; (2) avoidance forces from other vessel segments and the boundaries of the myocardium, and (3) optimality principles which minimize the drag force at the bifurcations of the generated tree. Using this algorithm, the 3D computational model of the largest six orders of the coronary arterial tree was generated, which spread across the myocardium of the left and right ventricles. The 3D coronary arterial tree model was then extended to 4D to simulate different cardiac phases by deforming the original 3D model according to the motion vector map of the 4D cardiac model of the XCAT phantom at the corresponding phases. As a result, a detailed and realistic 4D model of the coronary arterial tree was developed for the XCAT phantom by imposing constraints of anatomical and physiological characteristics of the coronary vasculature. This new 4D coronary artery tree model provides a unique simulation tool that can be

  12. Super-resolution reconstruction for 4D computed tomography of the lung via the projections onto convex sets approach

    SciTech Connect

    Zhang, Yu E-mail: qianjinfeng08@gmail.com; Wu, Xiuxiu; Yang, Wei; Feng, Qianjin E-mail: qianjinfeng08@gmail.com; Chen, Wufan

    2014-11-01

    Purpose: The use of 4D computed tomography (4D-CT) of the lung is important in lung cancer radiotherapy for tumor localization and treatment planning. Sometimes, dense sampling is not acquired along the superior–inferior direction. This disadvantage results in an interslice thickness that is much greater than in-plane voxel resolutions. Isotropic resolution is necessary for multiplanar display, but the commonly used interpolation operation blurs images. This paper presents a super-resolution (SR) reconstruction method to enhance 4D-CT resolution. Methods: The authors assume that the low-resolution images of different phases at the same position can be regarded as input “frames” to reconstruct high-resolution images. The SR technique is used to recover high-resolution images. Specifically, the Demons deformable registration algorithm is used to estimate the motion field between different “frames.” Then, the projection onto convex sets approach is implemented to reconstruct high-resolution lung images. Results: The performance of the SR algorithm is evaluated using both simulated and real datasets. Their method can generate clearer lung images and enhance image structure compared with cubic spline interpolation and back projection (BP) method. Quantitative analysis shows that the proposed algorithm decreases the root mean square error by 40.8% relative to cubic spline interpolation and 10.2% versus BP. Conclusions: A new algorithm has been developed to improve the resolution of 4D-CT. The algorithm outperforms the cubic spline interpolation and BP approaches by producing images with markedly improved structural clarity and greatly reduced artifacts.

  13. Enterococcus faecalis promotes osteoclastogenesis and semaphorin 4D expression.

    PubMed

    Wang, Shuai; Deng, Zuhui; Seneviratne, Chaminda J; Cheung, Gary S P; Jin, Lijian; Zhao, Baohong; Zhang, Chengfei

    2015-10-01

    Enterococcus faecalis is considered a major bacterial pathogen implicated in endodontic infections and contributes considerably to periapical periodontitis. This study aimed to investigate the potential mechanisms by which E. faecalis accounts for the bone destruction in periapical periodontitis in vitro. Osteoclast precursor RAW264.7 cells were treated with E. faecalis ATCC 29212 and a wild strain of E. faecalis derived clinically from an infected root canal. The results showed that, to some extent, E. faecalis induced the RAW264.7 cells to form tartrate-resistant acid phosphatase (TRAP)-positive multinucleated osteoclast-like cells. This pathogen markedly stimulated RAW264.7 cells to express semaphorin 4D (Sema4D), which inhibits bone formation. Once RAW264.7 cells were primed by low-dose receptor activator of nuclear factor-kappa B ligand (RANKL), E. faecalis could significantly increase the production of TRAP-positive multinucleated cells and up-regulate the expression of osteoclast-specific markers, including NFATc1, TRAP and cathepsin K. Both p38 and ERK1/2 MAPK signaling pathways were activated by E. faecalis in RANKL-primed RAW264.7 cells, and meanwhile the expression of Sema4D was highly increased. In conclusion, E. faecalis may greatly contribute to the bone resorption in periapical periodontitis by promoting RANKL-dependent osteoclastogenesis and expression of Sema4D through activation of p38 and ERK1/2 MAPK signaling pathways.

  14. The technology and performance of 4D ultrasound.

    PubMed

    Obruchkov, Sergei

    2008-01-01

    Recent developments in 4D ultrasound imaging technology allow clinicians to obtain not only rich visual information but also quantitative data that can be used for diagnosis and treatment. Some argue that the extension of 2D ultrasound is unnecessary and does not offer any benefits to diagnosis, while others argue that it is possible to better assess an abnormality in 3D than 2D. Anatomy can be reconstructed in perspectives that were never seen with conventional 2D US imaging. Advanced rendering techniques in three dimensions can be customized to be sensitive to specific pathology, thus making diagnosis more accurate. Volume and function of certain anatomical components can be measured with greater accuracy. This article reviews physical principles behind the ultrasound technology, how they are applied to advance the field of ultrasound imaging, and maybe reach its limits. Advances in ultrasound technology make 4D ultrasound imaging faster and less dependent on the operator's expertise, thus opening up more research possibilities in the fields of data processing and visualization. Currently, 4D ultrasound is extensively used in the field of obstetrics and interven-tional radiology. The goal of 4D ultrasound is to overcome the limitations posed by its predecessor technology and to be more clinically useful as an imaging tool.

  15. 2,4-Dichlorophenoxyacetic acid (2,4-D)

    Integrated Risk Information System (IRIS)

    2,4 - Dichlorophenoxyacetic acid ( 2,4 - D ) ; CASRN 94 - 75 - 7 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Asses

  16. 4D flow mri post-processing strategies for neuropathologies

    NASA Astrophysics Data System (ADS)

    Schrauben, Eric Mathew

    4D flow MRI allows for the measurement of a dynamic 3D velocity vector field. Blood flow velocities in large vascular territories can be qualitatively visualized with the added benefit of quantitative probing. Within cranial pathologies theorized to have vascular-based contributions or effects, 4D flow MRI provides a unique platform for comprehensive assessment of hemodynamic parameters. Targeted blood flow derived measurements, such as flow rate, pulsatility, retrograde flow, or wall shear stress may provide insight into the onset or characterization of more complex neuropathologies. Therefore, the thorough assessment of each parameter within the context of a given disease has important medical implications. Not surprisingly, the last decade has seen rapid growth in the use of 4D flow MRI. Data acquisition sequences are available to researchers on all major scanner platforms. However, the use has been limited mostly to small research trials. One major reason that has hindered the more widespread use and application in larger clinical trials is the complexity of the post-processing tasks and the lack of adequate tools for these tasks. Post-processing of 4D flow MRI must be semi-automated, fast, user-independent, robust, and reliably consistent for use in a clinical setting, within large patient studies, or across a multicenter trial. Development of proper post-processing methods coupled with systematic investigation in normal and patient populations pushes 4D flow MRI closer to clinical realization while elucidating potential underlying neuropathological origins. Within this framework, the work in this thesis assesses venous flow reproducibility and internal consistency in a healthy population. A preliminary analysis of venous flow parameters in healthy controls and multiple sclerosis patients is performed in a large study employing 4D flow MRI. These studies are performed in the context of the chronic cerebrospinal venous insufficiency hypothesis. Additionally, a

  17. Aiming at One-Stage Corrective Surgery for Extended Thoracic Aortic Dilatation

    PubMed Central

    Niinimaki, Eetu; Kajander, Henri; Paavonen, Timo; Sioris, Thanos; Mennander, Ari

    2014-01-01

    Definitive treatment of extended thoracic aortic dilatation is a major surgical challenge. Histopathology of resected thoracic aortic wall may reveal undiagnosed aortitis affecting outcome. We sought to investigate the benefit of thorough histopathology after one-stage corrective surgery for the treatment of extended thoracic aortic dilatation. Five patients underwent one-stage corrective surgery using the hybrid open arch repair by the frozen elephant trunk together with endovascular aortic grafting. A representative sample of the resected aortic arch was procured for histology. T- and B-lymphocytes, plasma cells, macrophages, and immunoglobulin G4 (IgG4) positivity were evaluated by immunohistochemistry. The mean preoperative maximum aortic diameter was 54 mm (range, 41–79 mm). The mean follow-up was 18 months (range, 1–24 months). As confirmed by computed tomography (CT) upon follow-up, complete thrombosis of the false lumen at the level of the frozen elephant trunk was achieved in all patients with dissection. One patient was operated due to atherosclerotic dilatation of the thoracic aorta, and postoperative CT showed successful exclusion of the atherosclerotic dilatation; this 75-year-old man was diagnosed with IgG4-positive aortitis and experienced unexpected blindness after surgery without evidence of emboli or long-term neurological impairment upon repeated brain CT. The hybrid open arch repair by the frozen elephant trunk and simultaneous endovascular repair is a feasible choice for one-stage surgery through sternotomy aiming at definitive treatment of extended thoracic aortic pathology. However, systematic evaluation of inflammation may reveal concealed aortitis affecting postoperative outcome and need for long-term surveillance. PMID:25075162

  18. Cross-sectional imaging of thoracic and abdominal complications of cerebrospinal fluid shunt catheters.

    PubMed

    Bolster, Ferdia; Fardanesh, Reza; Morgan, Tara; Katz, Douglas S; Daly, Barry

    2016-04-01

    This study aims to review the imaging findings of distal (thoracic and abdominal) complications related to ventriculo-peritoneal (VP), ventriculo-pleural (VPL), and ventriculo-atrial (VA) cerebrospinal fluid (CSF) shunt catheter placement. Institution review board-approved single-center study of patients with thoracic and abdominal CSF catheter-related complications on cross-sectional imaging examinations over a 14-year period was performed. Clinical presentation, patient demographics, prior medical history, and subsequent surgical treatment were recorded. The presence or absence of CSF catheter-related infection and/or acute hydrocephalus on cross-sectional imaging was also recorded. There were 81 distal CSF catheter-related complications identified on 47 thoracic or abdominal imaging examinations in 30 patients (age 5-80 years, mean 39.3 years), most often on CT (CT = 42, MRI = 1, US = 4). Complications included 38 intraperitoneal and 11 extraperitoneal fluid collections. Extraperitoneal collections included nine abdominal wall subcutaneous (SC) pseudocysts associated with shunt migration and obesity, an intrapleural pseudocyst, and a breast pseudocyst. There were also two large VPL-related pleural effusions, a fractured catheter in the SC tissues, and a large VA shunt thrombus within the right atrium. Ten patients (33.3 %) had culture-positive infection from CSF or shunt catheter samples. Ten patients (33.3 %) had features of temporally related acute or worsening hydrocephalus on neuroimaging. In four of these patients, the detection of thoracic and abdominal complications on CT preceded and predicted the findings of acute hydrocephalus on cranial imaging. Thoracic and abdominal complications of CSF shunts, as can be identified on CT, include shunt infection and/or obstruction, may be both multiple and recurrent, and may be predictive of concurrent acute intracranial problems.

  19. 4D MR imaging using robust internal respiratory signal

    NASA Astrophysics Data System (ADS)

    Hui, CheukKai; Wen, Zhifei; Stemkens, Bjorn; Tijssen, R. H. N.; van den Berg, C. A. T.; Hwang, Ken-Pin; Beddar, Sam

    2016-05-01

    The purpose of this study is to investigate the feasibility of using internal respiratory (IR) surrogates to sort four-dimensional (4D) magnetic resonance (MR) images. The 4D MR images were constructed by acquiring fast 2D cine MR images sequentially, with each slice scanned for more than one breathing cycle. The 4D volume was then sorted retrospectively using the IR signal. In this study, we propose to use multiple low-frequency components in the Fourier space as well as the anterior body boundary as potential IR surrogates. From these potential IR surrogates, we used a clustering algorithm to identify those that best represented the respiratory pattern to derive the IR signal. A study with healthy volunteers was performed to assess the feasibility of the proposed IR signal. We compared this proposed IR signal with the respiratory signal obtained using respiratory bellows. Overall, 99% of the IR signals matched the bellows signals. The average difference between the end inspiration times in the IR signal and bellows signal was 0.18 s in this cohort of matching signals. For the acquired images corresponding to the other 1% of non-matching signal pairs, the respiratory motion shown in the images was coherent with the respiratory phases determined by the IR signal, but not the bellows signal. This suggested that the IR signal determined by the proposed method could potentially correct the faulty bellows signal. The sorted 4D images showed minimal mismatched artefacts and potential clinical applicability. The proposed IR signal therefore provides a feasible alternative to effectively sort MR images in 4D.

  20. Learning distance function for regression-based 4D pulmonary trunk model reconstruction estimated from sparse MRI data

    NASA Astrophysics Data System (ADS)

    Vitanovski, Dime; Tsymbal, Alexey; Ionasec, Razvan; Georgescu, Bogdan; Zhou, Shaohua K.; Hornegger, Joachim; Comaniciu, Dorin

    2011-03-01

    Congenital heart defect (CHD) is the most common birth defect and a frequent cause of death for children. Tetralogy of Fallot (ToF) is the most often occurring CHD which affects in particular the pulmonary valve and trunk. Emerging interventional methods enable percutaneous pulmonary valve implantation, which constitute an alternative to open heart surgery. While minimal invasive methods become common practice, imaging and non-invasive assessment tools become crucial components in the clinical setting. Cardiac computed tomography (CT) and cardiac magnetic resonance imaging (cMRI) are techniques with complementary properties and ability to acquire multiple non-invasive and accurate scans required for advance evaluation and therapy planning. In contrary to CT which covers the full 4D information over the cardiac cycle, cMRI often acquires partial information, for example only one 3D scan of the whole heart in the end-diastolic phase and two 2D planes (long and short axes) over the whole cardiac cycle. The data acquired in this way is called sparse cMRI. In this paper, we propose a regression-based approach for the reconstruction of the full 4D pulmonary trunk model from sparse MRI. The reconstruction approach is based on learning a distance function between the sparse MRI which needs to be completed and the 4D CT data with the full information used as the training set. The distance is based on the intrinsic Random Forest similarity which is learnt for the corresponding regression problem of predicting coordinates of unseen mesh points. Extensive experiments performed on 80 cardiac CT and MR sequences demonstrated the average speed of 10 seconds and accuracy of 0.1053mm mean absolute error for the proposed approach. Using the case retrieval workflow and local nearest neighbour regression with the learnt distance function appears to be competitive with respect to "black box" regression with immediate prediction of coordinates, while providing transparency to the

  1. Ansys Fluent versus Sim Vascular for 4-D patient-specific computational hemodynamics in renal arteries

    NASA Astrophysics Data System (ADS)

    Mumbaraddi, Avinash; Yu, Huidan (Whitney); Sawchuk, Alan; Dalsing, Michael

    2015-11-01

    The objective of this clinical-need driven research is to investigate the effect of renal artery stenosis (RAS) on the blood flow and wall shear stress in renal arteries through 4-D patient-specific computational hemodynamics (PSCH) and search for possible critical RASs that significantly alter the pressure gradient across the stenosis by manually varying the size of RAS from 50% to 95%. The identification of the critical RAS is important to understand the contribution of RAS to the overall renal resistance thus appropriate clinical therapy can be determined in order to reduce the hypertension. Clinical CT angiographic data together with Doppler Ultra sound images of an anonymous patient are used serving as the required inputs of the PSCH. To validate the PSCH, we use both Ansys Fluent and Sim Vascular and compare velocity, pressure, and wall-shear stress under identical conditions. Renal Imaging Technology Development Program (RITDP) Grant.

  2. Head CT scan

    MedlinePlus

    Brain CT; Cranial CT; CT scan - skull; CT scan - head; CT scan - orbits; CT scan - sinuses; Computed tomography - cranial; CAT scan - brain ... conditions: Birth (congenital) defect of the head or brain Brain infection Brain tumor Buildup of fluid inside ...

  3. Combined convective and diffusive simulations: VERB-4D comparison with 17 March 2013 Van Allen Probes observations: VERB-4D

    SciTech Connect

    Shprits, Yuri Y.; Kellerman, Adam C.; Drozdov, Alexander Y.; Spence, Harlan E.; Reeves, Geoffrey D.; Baker, Daniel N.

    2015-11-19

    Our study focused on understanding the coupling between different electron populations in the inner magnetosphere and the various physical processes that determine evolution of electron fluxes at different energies. Observations during the 17 March 2013 storm and simulations with a newly developed Versatile Electron Radiation Belt-4D (VERB-4D) are presented. This analysis of the drift trajectories of the energetic and relativistic electrons shows that electron trajectories at transitional energies with a first invariant on the scale of ~100 MeV/G may resemble ring current or relativistic electron trajectories depending on the level of geomagnetic activity. Simulations with the VERB-4D code including convection, radial diffusion, and energy diffusion are presented. Sensitivity simulations including various physical processes show how different acceleration mechanisms contribute to the energization of energetic electrons at transitional energies. In particular, the range of energies where inward transport is strongly influenced by both convection and radial diffusion are studied. Our results of the 4-D simulations are compared to Van Allen Probes observations at a range of energies including source, seed, and core populations of the energetic and relativistic electrons in the inner magnetosphere.

  4. Combined convective and diffusive simulations: VERB-4D comparison with 17 March 2013 Van Allen Probes observations: VERB-4D

    DOE PAGES

    Shprits, Yuri Y.; Kellerman, Adam C.; Drozdov, Alexander Y.; ...

    2015-11-19

    Our study focused on understanding the coupling between different electron populations in the inner magnetosphere and the various physical processes that determine evolution of electron fluxes at different energies. Observations during the 17 March 2013 storm and simulations with a newly developed Versatile Electron Radiation Belt-4D (VERB-4D) are presented. This analysis of the drift trajectories of the energetic and relativistic electrons shows that electron trajectories at transitional energies with a first invariant on the scale of ~100 MeV/G may resemble ring current or relativistic electron trajectories depending on the level of geomagnetic activity. Simulations with the VERB-4D code including convection,more » radial diffusion, and energy diffusion are presented. Sensitivity simulations including various physical processes show how different acceleration mechanisms contribute to the energization of energetic electrons at transitional energies. In particular, the range of energies where inward transport is strongly influenced by both convection and radial diffusion are studied. Our results of the 4-D simulations are compared to Van Allen Probes observations at a range of energies including source, seed, and core populations of the energetic and relativistic electrons in the inner magnetosphere.« less

  5. SU-E-T-790: Validation of 4D Measurement-Guided Dose Reconstruction (MGDR) with OCTAVIUS 4D System

    SciTech Connect

    Lee, V; Leung, R; Wong, M; Law, G; Lee, K; Tung, S; Chan, M; Blanck, O

    2015-06-15

    Purpose: To validate the MGDR of OCTAVIUS 4D system (PTW, Freiburg, Germany) for quality assurance (QA) of volumetric-modulated arc radiotherapy (VMAT). Methods: 4D-MGDR measurements were divided into two parts: 1) square fields from 2×2 to 25×25 cm{sup 2} at 0°, 10° and 45° gantry, and 2) 8 VMAT plans (5 nasopharyngeal and 3 prostate) collapsed to gantry 40° in QA mode in Monaco v5.0 (Elekta, CMS, Maryland Heights, MO) were delivered on the OCTAVIUS 4D phantom with the OCTAVIUS 1500 detector plane perpendicular to either the incident beam to obtain the reconstructed dose (OCTA4D) or the 0° gantry axis to obtain the raw doses (OCTA3D) in Verisoft 6.1 (PTW, Freiburg, Germany). Raw measurements of OCTA3D were limited to < 45° gantry to avoid >0.5% variation of detector angular response with respect to 0° gantry as determined previously. Reconstructed OCTA4D and raw OCTA3D doses for all plans were compared at the same detector plane using γ criteria of 2% (local dose)/2mm and 3%/3mm criteria. Results: At gantry 0° and 10°, the γ results for all OCTA4D on detector plane coinciding with OCTA3D were over 90% at 2%/2mm except for the largest field (25×25 cm{sup 2} ) showing >88%. For square field at 45° gantry, γ passing rate is > 90% for fields smaller than 15x 15cm2 but < 80% for field size of 20 x20 cm{sup 2} upward. For VMAT, γ results showed 94% and 99% passing rate at 2%/2mm and 3%/3mm, respectively. Conclusion: OCTAVIUS 4D system has compromised accuracy in reconstructing dose away from the central beam axis, possibly due to the off-axis softening correction and errors of the percent depth dose data necessary as input for MGDR. Good results in VMAT delivery suggested that the system is relatively reliable for VMAT with small segments.

  6. Doctors of Thoracic Surgery: The Division of Thoracic Surgery at Toronto General Hospital.

    PubMed

    Keshavjee, Shaf; Spatafora, Lisa

    2015-01-01

    The Division of Thoracic Surgery at Toronto General Hospital has a history of sustained excellence and commitment to patient care, research and innovation in Thoracic Surgery. Doctors of Thoracic Surgery (DOTSR) continues to be a leading thoracic division training surgeons who practice all over the world--impacting the treatment of patients with thoracic disease. Many leaders in our specialty worldwide have directly or indirectly trained in Toronto. At University Health Network and the University of Toronto, this academic division has continued to contribute and thrive in a highly supportive and productive research and clinical environment.

  7. Evolution of thoracic surgery in Canada

    PubMed Central

    Deslauriers, Jean; Griffith Pearson, F; Nelems, Bill

    2015-01-01

    BACKGROUND: Canada’s contributions toward the 21st century’s practice of thoracic surgery have been both unique and multilayered. Scattered throughout are tales of pioneers where none had gone before, where opportunities were greeted by creativity and where iconic figures followed one another. OBJECTIVE: To describe the numerous and important achievements of Canadian thoracic surgeons in the areas of surgery for pulmonary tuberculosis, thoracic oncology, airway surgery and lung transplantation. METHOD: Information was collected through reading of the numerous publications written by Canadian thoracic surgeons over the past 100 years, interviews with interested people from all thoracic surgery divisions across Canada and review of pertinent material form the archives of several Canadian hospitals and universities. RESULTS: Many of the developments occurred by chance. It was the early and specific focus on thoracic surgery, to the exclusion of cardiac and general surgery, that distinguishes the Canadian experience, a model that is now emerging everywhere. From lung transplantation in chimera twin calves to ex vivo organ preservation, from the removal of airways to tissue regeneration, and from intensive care research to complex science, Canadians have excelled in their commitment to research. Over the years, the influence of Canadian thoracic surgery on international practice has been significant. CONCLUSIONS: Canada spearheaded the development of thoracic surgery over the past 100 years to a greater degree than any other country. From research to education, from national infrastructures to the regionalization of local practices, it happened in Canada.

  8. A new spin foam model for 4D gravity

    NASA Astrophysics Data System (ADS)

    Freidel, Laurent; Krasnov, Kirill

    2008-06-01

    Starting from Plebanski formulation of gravity as a constrained BF theory we propose a new spin foam model for 4D Riemannian quantum gravity that generalizes the well-known Barrett Crane model and resolves the inherent to it ultra-locality problem. The BF formulation of 4D gravity possesses two sectors: gravitational and topological ones. The model presented here is shown to give a quantization of the gravitational sector, and is dual to the recently proposed spin foam model of Engle et al which, we show, corresponds to the topological sector. Our methods allow us to introduce the Immirzi parameter into the framework of spin foam quantization. We generalize some of our considerations to the Lorentzian setting and obtain a new spin foam model in that context as well.

  9. 4D embryonic cardiography using gated optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Jenkins, M. W.; Rothenberg, F.; Roy, D.; Nikolski, V. P.; Hu, Z.; Watanabe, M.; Wilson, D. L.; Efimov, I. R.; Rollins, A. M.

    2006-01-01

    Simultaneous imaging of very early embryonic heart structure and function has technical limitations of spatial and temporal resolution. We have developed a gated technique using optical coherence tomography (OCT) that can rapidly image beating embryonic hearts in four-dimensions (4D), at high spatial resolution (10-15 μm), and with a depth penetration of 1.5 - 2.0 mm that is suitable for the study of early embryonic hearts. We acquired data from paced, excised, embryonic chicken and mouse hearts using gated sampling and employed image processing techniques to visualize the hearts in 4D and measure physiologic parameters such as cardiac volume, ejection fraction, and wall thickness. This technique is being developed to longitudinally investigate the physiology of intact embryonic hearts and events that lead to congenital heart defects.

  10. Intelligent Vehicle Systems: A 4D/RCS Approach

    SciTech Connect

    Madhavan, Raj

    2007-04-01

    This book presents new research on autonomous mobility capabilities and shows how technological advances can be anticipated in the coming two decades. An in-depth description is presented on the theoretical foundations and engineering approaches that enable these capabilities. Chapter 1 provides a brief introduction to the 4D/RCS reference model architecture and design methodology that has proven successful in guiding the development of autonomous mobility systems. Chapters 2 through 7 provide more detailed descriptions of research that has been conducted and algorithms that have been developed to implement the various aspects of the 4D/RCS reference model architecture and design methodology. Chapters 8 and 9 discuss applications, performance measures, and standards. Chapter 10 provides a history of Army and DARPA research in autonomous ground mobility. Chapter 11 provides a perspective on the potential future developments in autonomous mobility.

  11. The Thoracic Shape of Hominoids

    PubMed Central

    Chan, Lap Ki

    2014-01-01

    In hominoids, the broad thorax has been assumed to contribute to their dorsal scapular position. However, the dorsoventral diameter of their cranial thorax was found in one study to be longer in hominoids. There are insufficient data on thoracic shape to explain the relationship between broad thorax and dorsal scapular position. The current study presents data on multilevel cross-sectional shape and volume distribution in a range of primates. Biplanar radiographs of intact fluid-preserved cadavers were taken to measure the cross-sectional shape of ten equally spaced levels through the sternum (called decisternal levels) and the relative volume of the nine intervening thoracic segments. It was found that the cranial thorax of hominoids is larger and broader (except in the first two decisternal levels) than that of other primates. The cranial thorax of hominoids has a longer dorsoventral diameter because the increase in dorsoventral diameter caused by the increase in the volume of the cranial thorax overcompensates for the decrease caused by the broadening of the cranial thorax. The larger and broader cranial thorax in hominoids can be explained as a locomotor adaptation for scapular gliding and as a respiratory adaptation for reducing the effects of orthograde posture on ventilation-perfusion inequality. PMID:24818026

  12. Thoracic organ transplantation: laboratory methods.

    PubMed

    Patel, Jignesh K; Kobashigawa, Jon A

    2013-01-01

    Although great progress has been achieved in thoracic organ transplantation through the development of effective immunosuppression, there is still significant risk of rejection during the early post-transplant period, creating a need for routine monitoring for both acute antibody and cellular mediated rejection. The currently available multiplexed, microbead assays utilizing solubilized HLA antigens afford the capability of sensitive detection and identification of HLA and non-HLA specific antibodies. These assays are being used to assess the relative strength of donor specific antibodies; to permit performance of virtual crossmatches which can reduce the waiting time to transplantation; to monitor antibody levels during desensitization; and for heart transplants to monitor antibodies post-transplant. For cell mediated immune responses, the recent development of gene expression profiling has allowed noninvasive monitoring of heart transplant recipients yielding predictive values for acute cellular rejection. T cell immune monitoring in heart and lung transplant recipients has allowed individual tailoring of immunosuppression, particularly to minimize risk of infection. While the current antibody and cellular laboratory techniques have enhanced the ability to manage thoracic organ transplant recipients, future developments from improved understanding of microchimerism and graft tolerance may allow more refined allograft monitoring techniques.

  13. Bilateral internal thoracic artery grafting

    PubMed Central

    2013-01-01

    The effectiveness of the left internal mammary artery graft to the anterior descending coronary artery as a surgical strategy has been shown to improve the survival rate and decrease the risk of adverse cardiac events in patients undergoing coronary bypass surgery. These clinical benefits appear to be related to the superior short and long-term patency rates of the internal thoracic artery graft. Although the advantages of using of both internal thoracic arteries (ITA) for bypass grafting have taken longer to prove, recent results from multiple data sets now support these findings. The major advantage of bilateral ITA grafting appears to be improved survival rate, while the disadvantages of complex ITA grafting include the increased complexity of operation, and an increased risk of wound complications. While these short-term disadvantages have been mitigated in contemporary surgical practice, they have not eliminated. Bilateral ITA grafting should be considered the procedure of choice for patients undergoing coronary bypass surgery that have a predicted survival rate of longer than ten years. PMID:23977627

  14. 4D flow cardiovascular magnetic resonance consensus statement.

    PubMed

    Dyverfeldt, Petter; Bissell, Malenka; Barker, Alex J; Bolger, Ann F; Carlhäll, Carl-Johan; Ebbers, Tino; Francios, Christopher J; Frydrychowicz, Alex; Geiger, Julia; Giese, Daniel; Hope, Michael D; Kilner, Philip J; Kozerke, Sebastian; Myerson, Saul; Neubauer, Stefan; Wieben, Oliver; Markl, Michael

    2015-08-10

    Pulsatile blood flow through the cavities of the heart and great vessels is time-varying and multidirectional. Access to all regions, phases and directions of cardiovascular flows has formerly been limited. Four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) has enabled more comprehensive access to such flows, with typical spatial resolution of 1.5×1.5×1.5 - 3×3×3 mm(3), typical temporal resolution of 30-40 ms, and acquisition times in the order of 5 to 25 min. This consensus paper is the work of physicists, physicians and biomedical engineers, active in the development and implementation of 4D Flow CMR, who have repeatedly met to share experience and ideas. The paper aims to assist understanding of acquisition and analysis methods, and their potential clinical applications with a focus on the heart and greater vessels. We describe that 4D Flow CMR can be clinically advantageous because placement of a single acquisition volume is straightforward and enables flow through any plane across it to be calculated retrospectively and with good accuracy. We also specify research and development goals that have yet to be satisfactorily achieved. Derived flow parameters, generally needing further development or validation for clinical use, include measurements of wall shear stress, pressure difference, turbulent kinetic energy, and intracardiac flow components. The dependence of measurement accuracy on acquisition parameters is considered, as are the uses of different visualization strategies for appropriate representation of time-varying multidirectional flow fields. Finally, we offer suggestions for more consistent, user-friendly implementation of 4D Flow CMR acquisition and data handling with a view to multicenter studies and more widespread adoption of the approach in routine clinical investigations.

  15. Repairing Stevenson's step in the 4d Ising model

    NASA Astrophysics Data System (ADS)

    Balog, Janos; Niedermayer, Ferenc; Weisz, Peter

    2006-05-01

    In a recent paper Stevenson claimed that analysis of the data on the wave function renormalization constant near the critical point of the 4d Ising model is not consistent with analytical expectations. Here we present data with improved statistics and show that the results are indeed consistent with conventional wisdom once one takes into account the uncertainty of lattice artifacts in the analytical computations.

  16. Phosphodiesterase 4D gene polymorphisms in sudden sensorineural hearing loss.

    PubMed

    Chien, Chen-Yu; Tai, Shu-Yu; Wang, Ling-Feng; Hsi, Edward; Chang, Ning-Chia; Wang, Hsun-Mo; Wu, Ming-Tsang; Ho, Kuen-Yao

    2016-09-01

    The phosphodiesterase 4D (PDE4D) gene has been reported as a risk gene for ischemic stroke. The vascular factors are between the hypothesized etiologies of sudden sensorineural hearing loss (SSNHL), and this genetic effect might be attributed for its role in SSNHL. We hypothesized that genetic variants of the PDE4D gene are associated with susceptibility to SSNHL. We conducted a case-control study with 362 SSNHL cases and 209 controls. Three single nucleotide polymorphisms (SNPs) were selected. The genotypes were determined using TaqMan technology. Hardy-Weinberg equilibrium (HWE) was tested for each SNP, and genetic effects were evaluated according to three inheritance modes. We carried out sex-specific analysis to analyze the overall data. All three SNPs were in HWE. When subjects were stratified by sex, the genetic effect was only evident in females but not in males. The TT genotype of rs702553 exhibited an adjusted odds ratio (OR) of 3.83 (95 % confidence interval = 1.46-11.18) (p = 0.006) in female SSNHL. The TT genotype of SNP rs702553 was associated with female SSNHL under the recessive model (p = 0.004, OR 3.70). In multivariate logistic regression analysis, TT genotype of rs702553 was significantly associated with female SSNHL (p = 0.0043, OR 3.70). These results suggest that PDE4D gene polymorphisms influence the susceptibility for the development of SSNHL in the southern Taiwanese female population.

  17. Real-time 4D ultrasound mosaicing and visualization.

    PubMed

    Brattain, Laura J; Howe, Robert D

    2011-01-01

    Intra-cardiac 3D ultrasound imaging has enabled new minimally invasive procedures. Its narrow field of view, however, limits its efficacy in guiding beating heart procedures where geometrically complex and spatially extended moving anatomic structures are often involved. In this paper, we present a system that performs electrocardiograph gated 4D mosaicing and visualization of 3DUS volumes. Real-time operation is enabled by GPU implementation. The method is validated on phantom and porcine heart data.

  18. A Case of Patent Ductus Arteriosus in an Elderly Patient Treated by Thoracic Endovascular Aortic Repair

    PubMed Central

    Ishibashi, Hiroyuki; Sugimoto, Ikuo; Yamada, Tetsuya; Maruyama, Yuki; Hagihara, Makiyo; Ishiguchi, Tsuneo

    2016-01-01

    The patient described herein was a 75-year-old female. Echocardiography showed patent ductus arteriosus (PDA). Heart failure symptoms gradually appeared, and she was referred to our department for treatment. Contrast-enhanced computed tomography (CT) revealed a tubular structure communicating between the aortic arch and pulmonary artery trunk, suggesting adult PDA. Thoracic endovascular aortic repair (TEVAR) was performed to close PDA. Completion angiography confirmed the disappearance of PDA. Post-TEVAR CT revealed no endoleak. The patient was discharged from the hospital on the 11th day after surgery. TEVAR is more useful and less invasive for adult PDA than conventional open surgery. PMID:28018507

  19. 2D:4D Ratio and its Implications in Medicine

    PubMed Central

    Jeevanandam, Saravanakumar

    2016-01-01

    Digit ratios, especially 2D:4D ratio, a potential proxy marker for prenatal androgen exposure shows sexual dimorphism. Existing literature and recent research show accumulating evidence on 2D:4D ratio showing correlations with various phenotypic traits in humans. Ratio of 2D:4D is found to correlate negatively to testosterone and positively to oestrogen in the foetus. Interestingly, it is constant since birth and not influenced by the adult hormone levels. Usually, males have lower ratios when compared to females. Prenatal androgen exposure and therefore, digit ratios have been reported to be associated with numerical competencies, spatial skills, handedness, cognitive abilities, academic performance, sperm counts, personalities and prevalence of obesity, migraine, eating disorders, depression, myopia, autism etc. The authors have attempted to write a brief account on the digit ratios and the dimorphism observed in various physiological, psychological and behavioural traits. Also, the authors have discussed the relevant molecular basics and the methods of measurement of digit ratios. PMID:28208851

  20. 4D-Flow validation, numerical and experimental framework

    NASA Astrophysics Data System (ADS)

    Sansom, Kurt; Liu, Haining; Canton, Gador; Aliseda, Alberto; Yuan, Chun

    2015-11-01

    This work presents a group of assessment metrics of new 4D MRI flow sequences, an imaging modality that allows for visualization of three-dimensional pulsatile flow in the cardiovascular anatomy through time-resolved three-dimensional blood velocity measurements from cardiac-cycle synchronized MRI acquisition. This is a promising tool for clinical assessment but lacks a robust validation framework. First, 4D-MRI flow in a subject's stenotic carotid bifurcation is compared with a patient-specific CFD model using two different boundary condition methods. Second, Particle Image Velocimetry in a patient-specific phantom is used as a benchmark to compare the 4D-MRI in vivo measurements and CFD simulations under the same conditions. Comparison of estimated and measureable flow parameters such as wall shear stress, fluctuating velocity rms, Lagrangian particle residence time, will be discussed, with justification for their biomechanics relevance and the insights they can provide on the pathophysiology of arterial disease: atherosclerosis and intimal hyperplasia. Lastly, the framework is applied to a new sequence to provide a quantitative assessment. A parametric analysis on the carotid bifurcation pulsatile flow conditions will be presented and an accuracy assessment provided.

  1. Thoracic osteophyte: rare cause of esophageal perforation.

    PubMed

    Rathinam, S; Makarawo, T; Norton, R; Collins, F J

    2010-01-01

    Esophageal perforation is a difficult problem in thoracic surgery. Esophageal perforations can be spontaneous, iatrogenic, or malignant. We report two cases of esophageal perforations caused by thoracic osteophytes and different management strategies leading to successful outcomes. An 80-year-old male presented with chest pain and dysphagia following a fall. On endoscopy, an esophageal perforation and foreign body was noted which was confirmed as a thoracic osteophyte on computed tomography scan. He was managed conservatively as he declined surgery. A 63-year-old male was admitted with dysphagia following a food bolus obstruction. Following esophagoscopy and dilatation, there was clinical and radiological evidence of perforation. During surgery, a thoracic osteophyte was identified as the cause of perforation. The perforation was closed in layers and the osteophyte was trimmed. Both patients recovered well. Thoracic osteophytes are a rare cause of esophageal perforations and a high index of suspicion is required in patients with osteoarthritis who present with esophageal perforations.

  2. Thoracic outlet syndrome in whiplash injury.

    PubMed Central

    Capistrant, T D

    1977-01-01

    Thirty-five cases of thoracic outlet syndrome complicating whiplash or cervical strain injury were studied. Thirty cases had confirmation by the demonstration of slowed ulnar nerve conduction velocity (UNCV) through the thoracic outlet. Two distinct groups of patients were found. An acute group, seen an average of 3 1/2 months post injury, had severe neck pain with often mild or incidental thoracic outlet syndrome. A chronic group, with symptoms persisting more than 2 years after cervical injury, often had thoracic outlet symptoms as the predominant complaint. This study suggests that the arm aches and parethesias seen in association with both acute and chronic cervical strain injury are most often secondary to thoracic outlet syndrome. PMID:836089

  3. Volumetric applications for spiral CT in the thorax

    NASA Astrophysics Data System (ADS)

    Rubin, Geoffrey D.; Napel, Sandy; Leung, Ann N.

    1994-05-01

    Spiral computed tomography (CT) is a new technique for rapidly acquiring volumetric data within the body. By combining a continuous gantry rotation and table feed, it is possible to image the entire thorax within a single breath-hold. This eliminates the ventilatory misregistration seen with conventional thoracic CT, which can result in small pulmonary lesions being undetected. An additional advantage of a continuous data set is that axial sections can be reconstructed at arbitrary intervals along the spiral path, resulting in the generation of overlapping sections which diminish partial volume effects resulting from lesions that straddle adjacent sections. The rapid acquisition of spiral CT enables up to a 50% reduction in the total iodinated contrast dose required for routine thoracic CT scanning. This can be very important for imaging patients with cardiac and renal diseases and could reduce the cost of thoracic CT scanning. Alternatively, by combining a high flow peripheral intravenous iodinated contrast injection with a spiral CT acquisition, it is possible to obtain images of the vasculature, which demonstrate pulmonary arterial thrombi, aortic aneurysms and dissections, and congenital vascular anomalies in detail previously unattainable without direct arterial access.

  4. Impact of scanning parameters and breathing patterns on image quality and accuracy of tumor motion reconstruction in 4D CBCT: a phantom study.

    PubMed

    Lee, Soyoung; Yan, Guanghua; Lu, Bo; Kahler, Darren; Li, Jonathan G; Sanjiv, Samat S

    2015-11-08

    Four-dimensional, cone-beam CT (4D CBCT) substantially reduces respiration-induced motion blurring artifacts in three-dimension (3D) CBCT. However, the image quality of 4D CBCT is significantly degraded which may affect its accuracy in localizing a mobile tumor for high-precision, image-guided radiation therapy (IGRT). The purpose of this study was to investigate the impact of scanning parameters hereinafter collectively referred to as scanning sequence) and breathing patterns on the image quality and the accuracy of computed tumor trajectory for a commercial 4D CBCT system, in preparation for its clinical implementation. We simulated a series of periodic and aperiodic sinusoidal breathing patterns with a respiratory motion phantom. The aperiodic pattern was created by varying the period or amplitude of individual sinusoidal breathing cycles. 4D CBCT scans of the phantom were acquired with a manufacturer-supplied scanning sequence (4D-S-slow) and two in-house modified scanning sequences (4D-M-slow and 4D-M-fast). While 4D-S-slow used small field of view (FOV), partial rotation (200°), and no imaging filter, 4D-M-slow and 4D-M-fast used medium FOV, full rotation, and the F1 filter. The scanning speed was doubled in 4D-M-fast (100°/min gantry rotation). The image quality of the 4D CBCT scans was evaluated using contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), and motion blurring ratio (MBR). The trajectory of the moving target was reconstructed by registering each phase of the 4D CBCT with a reference CT. The root-mean-squared-error (RMSE) analysis was used to quantify its accuracy. Significant decrease in CNR and SNR from 3D CBCT to 4D CBCT was observed. The 4D-S-slow and 4D-M-fast scans had comparable image quality, while the 4D-M-slow scans had better performance due to doubled projections. Both CNR and SNR decreased slightly as the breathing period increased, while no dependence on the amplitude was observed. The difference of both CNR and SNR

  5. Seeing the unseen--bioturbation in 4D: tracing bioirrigation in marine sediment using positron emission tomography and computed tomography.

    PubMed

    Delefosse, Matthieu; Kristensen, Erik; Crunelle, Diane; Braad, Poul Erik; Dam, Johan Hygum; Thisgaard, Helge; Thomassen, Anders; Høilund-Carlsen, Poul Flemming

    2015-01-01

    Understanding spatial and temporal patterns of bioirrigation induced by benthic fauna ventilation is critical given its significance on benthic nutrient exchange and biogeochemistry in coastal ecosystems. The quantification of this process challenges marine scientists because faunal activities and behaviors are concealed in an opaque sediment matrix. Here, we use a hybrid medical imaging technique, positron emission tomography and computed tomography (PET/CT) to provide a qualitative visual and fully quantitative description of bioirrigation in 4D (space and time). As a study case, we present images of porewater advection induced by the well-studied lugworm (Arenicola marina). Our results show that PET/CT allows more comprehensive studies on ventilation and bioirrigation than possible using techniques traditionally applied in marine ecology. We provide a dynamic three-dimensional description of bioirrigation by the lugworm at very high temporal and spatial resolution. Results obtained with the PET/CT are in agreement with literature data on lugworm ventilation and bioirrigation. Major advantages of PET/CT over methods commonly used are its non-invasive and non-destructive approach and its capacity to provide information that otherwise would require multiple methods. Furthermore, PET/CT scan is versatile as it can be used for a variety of benthic macrofauna species and sediment types and it provides information on burrow morphology or animal behavior. The lack of accessibility to the expensive equipment is its major drawback which can only be overcome through collaboration among several institutions.

  6. Seeing the Unseen—Bioturbation in 4D: Tracing Bioirrigation in Marine Sediment Using Positron Emission Tomography and Computed Tomography

    PubMed Central

    Delefosse, Matthieu; Kristensen, Erik; Crunelle, Diane; Braad, Poul Erik; Dam, Johan Hygum; Thisgaard, Helge; Thomassen, Anders; Høilund-Carlsen, Poul Flemming

    2015-01-01

    Understanding spatial and temporal patterns of bioirrigation induced by benthic fauna ventilation is critical given its significance on benthic nutrient exchange and biogeochemistry in coastal ecosystems. The quantification of this process challenges marine scientists because faunal activities and behaviors are concealed in an opaque sediment matrix. Here, we use a hybrid medical imaging technique, positron emission tomography and computed tomography (PET/CT) to provide a qualitative visual and fully quantitative description of bioirrigation in 4D (space and time). As a study case, we present images of porewater advection induced by the well-studied lugworm (Arenicola marina). Our results show that PET/CT allows more comprehensive studies on ventilation and bioirrigation than possible using techniques traditionally applied in marine ecology. We provide a dynamic three-dimensional description of bioirrigation by the lugworm at very high temporal and spatial resolution. Results obtained with the PET/CT are in agreement with literature data on lugworm ventilation and bioirrigation. Major advantages of PET/CT over methods commonly used are its non-invasive and non-destructive approach and its capacity to provide information that otherwise would require multiple methods. Furthermore, PET/CT scan is versatile as it can be used for a variety of benthic macrofauna species and sediment types and it provides information on burrow morphology or animal behavior. The lack of accessibility to the expensive equipment is its major drawback which can only be overcome through collaboration among several institutions. PMID:25837626

  7. New approach based on tetrahedral-mesh geometry for accurate 4D Monte Carlo patient-dose calculation

    NASA Astrophysics Data System (ADS)

    Han, Min Cheol; Yeom, Yeon Soo; Kim, Chan Hyeong; Kim, Seonghoon; Sohn, Jason W.

    2015-02-01

    In the present study, to achieve accurate 4D Monte Carlo dose calculation in radiation therapy, we devised a new approach that combines (1) modeling of the patient body using tetrahedral-mesh geometry based on the patient’s 4D CT data, (2) continuous movement/deformation of the tetrahedral patient model by interpolation of deformation vector fields acquired through deformable image registration, and (3) direct transportation of radiation particles during the movement and deformation of the tetrahedral patient model. The results of our feasibility study show that it is certainly possible to construct 4D patient models (= phantoms) with sufficient accuracy using the tetrahedral-mesh geometry and to directly transport radiation particles during continuous movement and deformation of the tetrahedral patient model. This new approach not only produces more accurate dose distribution in the patient but also replaces the current practice of using multiple 3D voxel phantoms and combining multiple dose distributions after Monte Carlo simulations. For routine clinical application of our new approach, the use of fast automatic segmentation algorithms is a must. In order to achieve, simultaneously, both dose accuracy and computation speed, the number of tetrahedrons for the lungs should be optimized. Although the current computation speed of our new 4D Monte Carlo simulation approach is slow (i.e. ~40 times slower than that of the conventional dose accumulation approach), this problem is resolvable by developing, in Geant4, a dedicated navigation class optimized for particle transportation in tetrahedral-mesh geometry.

  8. New approach based on tetrahedral-mesh geometry for accurate 4D Monte Carlo patient-dose calculation.

    PubMed

    Han, Min Cheol; Yeom, Yeon Soo; Kim, Chan Hyeong; Kim, Seonghoon; Sohn, Jason W

    2015-02-21

    In the present study, to achieve accurate 4D Monte Carlo dose calculation in radiation therapy, we devised a new approach that combines (1) modeling of the patient body using tetrahedral-mesh geometry based on the patient's 4D CT data, (2) continuous movement/deformation of the tetrahedral patient model by interpolation of deformation vector fields acquired through deformable image registration, and (3) direct transportation of radiation particles during the movement and deformation of the tetrahedral patient model. The results of our feasibility study show that it is certainly possible to construct 4D patient models (= phantoms) with sufficient accuracy using the tetrahedral-mesh geometry and to directly transport radiation particles during continuous movement and deformation of the tetrahedral patient model. This new approach not only produces more accurate dose distribution in the patient but also replaces the current practice of using multiple 3D voxel phantoms and combining multiple dose distributions after Monte Carlo simulations. For routine clinical application of our new approach, the use of fast automatic segmentation algorithms is a must. In order to achieve, simultaneously, both dose accuracy and computation speed, the number of tetrahedrons for the lungs should be optimized. Although the current computation speed of our new 4D Monte Carlo simulation approach is slow (i.e. ~40 times slower than that of the conventional dose accumulation approach), this problem is resolvable by developing, in Geant4, a dedicated navigation class optimized for particle transportation in tetrahedral-mesh geometry.

  9. Dosimetric Quantities for Computed Tomography Examinations of Paediatric Patients on the Thoracic and Abdominal Regions

    SciTech Connect

    Flores-M, E.; Gamboa de Buen, I.; Buenfil, A. E.; Ruiz-Trejo, C.; Dies, P.

    2010-12-07

    Computed Tomography (CT) is a high dose X ray imaging procedure and its use has rapidly increased in the last two decades fueled by the development of helical CT. The aim of this study is to present values of the dosimetric quantities for CT paediatric examinations of thoracic and abdominal regions. The protocols studied were those of chest, lung-mediastine, chest-abdomen, pulmonary high resolution and mediastine-abdomen, which are the more common examinations performed at ''Hospital Infantil de Mexico Federico Gomez'' in the thoracic-abdominal region. The measurements were performed on a Siemens SOMATOM Sensation 16 CT Scanner and the equipment used was a CT pencil ionization chamber, connected to an electrometer. This system was calibrated for RQT9 CT beam quality. A PMMA head phantom with diameter of 16 cm and length of 15 cm was also used. The dosimetric quantities measured were the weighted air kerma index (C{sub w}), the volumetric dose index (C{sub vol}) and the CT air kerma-length product. It was found that the pulmonary high resolution examination presented the highest values for the C{sub w}(31.1 mGy) and C{sub vol}(11.1 mGy). The examination with the lowest values of these two quantities was the chest-abdomen protocol with 10.5 mGy for C{sub w} and 5.5 mGy for C{sub vol}. However, this protocol presented the highest value for P{sub KL,CT}(282.2 mGy cm) when considering the average clinical length of the examinations.

  10. Dosimetric Quantities for Computed Tomography Examinations of Paediatric Patients on the Thoracic and Abdominal Regions

    NASA Astrophysics Data System (ADS)

    Flores-M, E.; Buenfil, A. E.; Dies, P.; Gamboa-deBuen, I.; Ruiz-Trejo, C.

    2010-12-01

    Computed Tomography (CT) is a high dose X ray imaging procedure and its use has rapidly increased in the last two decades fueled by the development of helical CT. The aim of this study is to present values of the dosimetric quantities for CT paediatric examinations of thoracic and abdominal regions. The protocols studied were those of chest, lung-mediastine, chest-abdomen, pulmonary high resolution and mediastine-abdomen, which are the more common examinations performed at "Hospital Infantil de México Federico Gómez" in the thoracic-abdominal region. The measurements were performed on a Siemens SOMATOM Sensation 16 CT Scanner and the equipment used was a CT pencil ionization chamber, connected to an electrometer. This system was calibrated for RQT9 CT beam quality. A PMMA head phantom with diameter of 16 cm and length of 15 cm was also used. The dosimetric quantities measured were the weighted air kerma index (Cw), the volumetric dose index (Cvol) and the CT air kerma-length product. It was found that the pulmonary high resolution examination presented the highest values for the Cw (31.1 mGy) and Cvol (11.1 mGy). The examination with the lowest values of these two quantities was the chest-abdomen protocol with 10.5 mGy for Cw and 5.5 mGy for Cvol. However, this protocol presented the highest value for PKL,CT (282.2 mGy cm) when considering the average clinical length of the examinations.

  11. LOX Mutations Predispose to Thoracic Aortic Aneurysms and Dissections

    PubMed Central

    Guo, Dong-chuan; Regalado, Ellen S.; Gong, Limin; Duan, Xueyan; Santos-Cortez, Regie Lyn P.; Arnaud, Pauline; Ren, Zhao; Cai, Bo; Hostetler, Ellen M.; Moran, Rocio; Liang, David; Estrera, Anthony; Safi, Hazim J; Leal, Suzanne M.; Bamshad, Michael J.; Shendure, Jay; Nickerson, Deborah A.; Jondeau, Guillaume; Boileau, Catherine; Milewicz, Dianna M.

    2016-01-01

    Rationale Mutations in several genes have been identified that are responsible for approximately 25% of families with familial thoracic aortic aneurysms and dissections (TAAD). However, the causative gene remains unknown in 75% of families. Objectives To identify the causative mutation in families with autosomal dominant inheritance of TAAD. Methods and Results Exome sequencing was used to identify the mutation responsible for a large family with TAAD. A heterozygous rare variant, c.839G>T (p.Ser280Arg), was identified in LOX, encoding a lysyl oxidase, that segregated with disease in the family. Sanger and exome sequencing was performed to investigate mutations in candidate genes in an additional 410 probands from unrelated families. Additional LOX rare variants that segregated with disease in families were identified, including c.125G>A (p.Trp42*), c.604G>T (p.Gly202*), c.743C>T (p.Thr248Ile), c.800A>C (p.Gln267Pro), and c.1044T>A (p.Ser348Arg). The altered amino acids cause haploinsufficiency for LOX or are located at a highly conserved LOX catalytic domain, which is relatively invariant in the population. Expression of the LOX variants p.Ser280Arg and p.Ser348Arg had significantly lower lysyl oxidase activity when compared with the wild type protein. Individuals with LOX variants had fusiform enlargement of the root and ascending thoracic aorta, leading to ascending aortic dissections. Conclusions These data, along with previous studies showing the deficiency of LOX in mice or inhibition of lysyl oxidases in turkeys and rats causes aortic dissections, support the conclusion that rare genetic variants in LOX predispose to thoracic aortic disease. PMID:26838787

  12. [Value of thoracoscopy in thoracic trauma--initial experiences].

    PubMed

    Lesser, T; Bartel, M

    1997-01-01

    The aim of this study was to assess the role of thoracoscopy in the evaluation of the cause of persistent intrathoracic bleeding, air leak, or nuclear basal opacification after blunt thoracic trauma. As a result, a decision to proceed to early thoracotomy could be made, or an attempt of thoracoscopic haemostasis, haematoma evacuation, or fistula closure was possible. Twelve patients (9 male, 3 female, mean age 33,7 years) with blunt thoracic trauma underwent video-assisted thoracoscopy under general anaesthesia with double-lumen endotracheal intubation and one-lung ventilation. The indication for operation was made after assessment of chest X-ray and CT findings, pleural ultrasound, and the volume and quality of pleural drainage. Persistent pneumothorax was shown to be due to traumatic rupture of a bulla in two cases and to parenchymal air-leak from a small lung laceration in two cases, all of which were treated endoscopically. In two cases a diaphragmatic rupture was confirmed as the cause of basal shadowing and in one case a major lower lobe laceration was identified as the cause of a persistent haemopneumothorax. In three cases, a fluid collection which could not be evacuated through a pleural drain was shown to be an organised haematoma and was removed endoscopically. Video-assisted thoracoscopy is helpful in the diagnosis and treatment of thoracic trauma, allowing early recognition of injuries that require thoracotomy. It is indicated for persistent (but not life-threatening) intrathoracic bleeding, unresolving pneumothorax, and unclear basal opacification. Therapeutic parenchymal tissue glue application and suturing as well as local resection and haematoma evacuation can be performed with this technique.

  13. Poster — Thur Eve — 71: A 4D Multimodal Lung Phantom for Regmentation Evaluation

    SciTech Connect

    Markel, D; Levesque, I R; El Naqa, I

    2014-08-15

    Segmentation and registration of medical imaging data are two processes that can be integrated (a process termed regmentation) to iteratively reinforce each other, potentially improving efficiency and overall accuracy. A significant challenge is presented when attempting to validate the joint process particularly with regards to minimizing geometric uncertainties associated with the ground truth while maintaining anatomical realism. This work demonstrates a 4D MRI, PET, and CT compatible tissue phantom with a known ground truth for evaluating registration and segmentation accuracy. The phantom consists of a preserved swine lung connected to an air pump via a PVC tube for inflation. Mock tumors were constructed from sea sponges contained within two vacuum-sealed compartments with catheters running into each one for injection of radiotracer solution. The phantom was scanned using a GE Discovery-ST PET/CT scanner and a 0.23T Phillips MRI, and resulted in anatomically realistic images. A bifurcation tracking algorithm was implemented to provide a ground truth for evaluating registration accuracy. This algorithm was validated using known deformations of up to 7.8 cm using a separate CT scan of a human thorax. Using the known deformation vectors to compare against, 76 bifurcation points were selected. The tracking accuracy was found to have maximum mean errors of −0.94, 0.79 and −0.57 voxels in the left-right, anterior-posterior and inferior-superior directions, respectively. A pneumatic control system is under development to match the respiratory profile of the lungs to a breathing trace from an individual patient.

  14. [Thoracic nocardiosis - a clinical report].

    PubMed

    Vale, Artur; Guerra, Miguel; Martins, Daniel; Lameiras, Angelina; Miranda, José; Vouga, Luís

    2014-01-01

    Nocardia genus microorganisms are ubiquitous, Gram positive aerobic bacterias, responsible for disease mainly in immunocompromised hosts, with cellular immune response commitment. Inhalation is the main form of transmition and pulmonary disease is the most frequent presentation. Dissemination may occur by contiguity and also via hematogenous. The clinical and imaging presentation is not specific, and diagnosis is obtained after identification of Nocardia bacteria in biological samples. Since there are no reliable studies that indicate the best therapeutic option, treatment should be individualized and based on antimicrobial susceptibility testing. Surgical drainage should also be considered in all patients. The authors present a clinical case of a patient with thoracic nocardiosis, and make a short literature review on the theme.

  15. Ossification of thoracic ligamenta flava

    SciTech Connect

    Kudo, S.; Minoru, O.; Russell, W.J.

    1983-07-01

    Although ligamentum flavum ossification (LFO) often occurs in normal persons, there are no reports of its detection on lateral chest radiographs made during screening examinations. Review of 1,744 consecutive lateral chest radiographs identified LFO in 6.2% of males and 4.8% of females. LFO occurred mainly at the intervertebral segments from T9-T10 through T12-L1. Most prevalent was the hook-shaped LFO, protruding inferoirly from the inferior facets into the projections of the intervertabral foramina. Though LFO can cause severe neurologic symptoms, none of the affected persons in this study reported such symptoms. LFO was first visualized radiographically when the subjects were 20-40 years old, and it may be a physiologic condition. The LFO in these cases existed independent of thoracic posterior longitudinal ligament ossification, diffuse idiopathic skeletal hyperostosis, and degenerative osteoarthritis.

  16. 4D seismic data acquisition method during coal mining

    NASA Astrophysics Data System (ADS)

    Du, Wen-Feng; Peng, Su-Ping

    2014-06-01

    In order to observe overburden media changes caused by mining processing, we take the fully-mechanized working face of the BLT coal mine in Shendong mine district as an example to develop a 4D seismic data acquisition methodology during coal mining. The 4D seismic data acquisition is implemented to collect 3D seismic data four times in different periods, such as before mining, during the mining process and after mining to observe the changes of the overburden layer during coal mining. The seismic data in the research area demonstrates that seismic waves are stronger in energy, higher in frequency and have better continuous reflectors before coal mining. However, all this is reversed after coal mining because the overburden layer has been mined, the seismic energy and frequency decrease, and reflections have more discontinuities. Comparing the records collected in the survey with those from newly mined areas and other records acquired in the same survey with the same geometry and with a long time for settling after mining, it clearly shows that the seismic reflections have stronger amplitudes and are more continuous because the media have recovered by overburden layer compaction after a long time of settling after mining. By 4D seismic acquisition, the original background investigation of the coal layers can be derived from the first records, then the layer structure changes can be monitored through the records of mining action and compaction action after mining. This method has laid the foundation for further research into the variation principles of the overburden layer under modern coal-mining conditions.

  17. Digit ratio (2D:4D), salivary testosterone, and handedness.

    PubMed

    Beaton, Alan A; Rudling, Nick; Kissling, Christian; Taurines, Regine; Thome, Johannes

    2011-03-01

    The length of the index finger relative to that of the ring finger, the 2D:4D ratio, has been taken to be a marker of the amount of testosterone (T) that was present in the foetal environment (Manning, Scutt, Wilson, & Lewis-Jones, 1998). It has also been suggested (Geschwind & Galaburda, 1987) that elevated levels of foetal T are associated with left-handedness and that adult levels of circulating T might relate to foetal levels (Jamison, Meier, & Campbell, 1993). We used multiple regression analyses to investigate whether there is any relationship between either left or right hand 2D:4D ratio and handedness. We also examined whether adult levels of salivary T (or cortisol, used as a control hormone) predict digit ratio and/or handedness. Although the 2D:4D ratio of neither the left nor the right hand was related to handedness, the difference between the digit ratios of the right and left hands, D(R-L), was a significant predictor of handedness and of the performance difference between the hands on a peg-moving task, supporting previous findings (Manning & Peters, 2009; Manning et al., 1998; Manning, Trivers, Thornhill, & Singh, 2000; Stoyanov, Marinov, & Pashalieva, 2009). Adult circulating T levels did not predict the digit ratio of the left or right hand; nor was there a significant relationship between concentrations of salivary T (or cortisol) and either hand preference or asymmetry in manual skill. We suggest that the association between D(R-L) and hand preference arises because D(R-L) is a correlate of sensitivity to T in the developing foetus.

  18. Transdiaphragmatic abscess: late thoracic complication of laparoscopic cholecystectomy.

    PubMed

    Preciado, A; Matthews, B D; Scarborough, T K; Marti, J L; Reardon, P R; Weinstein, G S; Bennett, M

    1999-12-01

    Spillage of gallstones into the peritoneal cavity is a frequent problem during laparoscopic cholecystectomy (as much as 30%) and is frequently dismissed as a benign occurrence. However, several complications associated with spillage of gallstones have been reported recently. Most of these complications presented late after the original procedure, many with clinical pictures not related to biliary etiology, confounding and delaying adequate management. For patients presenting with intraabdominal or thoracic abscesses of unknown etiology, if there is a history of laparoscopic cholecystectomy, regardless of the time interval, certain evaluations should be considered. A sonogram and a CT scan are advisable to detect retained extraluminal gallstones, as most patients will require, not only drainage of fluid collections, but also removal of the stones. A case is described of a patient who presented with a right empyema and transdiaphragmatic abscess 18 months after a laparoscopic cholecystectomy. Treatment included decortication, enbloc resection of the abscess, repair of the diaphragm, and drainage.

  19. A Case Of Atypical Presentation of Thoracic Osteomyelitis & Paraspinal Abscess

    PubMed Central

    Acharya, Utkarsh

    2008-01-01

    Here presented is a case involving a 44-year-old man with a chief complaint of sharp lateral right-sided rib pain with notable radiation to the anterior portion of the thorax and minor radiation around the lateral back. The etiology of the pain and radiculopathy, which was initially attributed to a right-sided rib fracture, was later accurately credited to a paraspinal abscess discovered on a lateral X-ray of the thoracic spine. Subsequently, studies including Magnetic Resonance Imaging (MRI), Computed Tomography (CT), and bone scan all confirmed the diagnosis of a paraspinal abscess between the right lobe and its neighboring T9 and T10 vertebrae. The mass was biopsied and methicillin sensitive Staphylococcus aureus was isolated. Appropriate surgical and medical intervention was possible due to the early diagnosis of the abscess. PMID:19148317

  20. CMT4D (NDRG1 mutation): genotype-phenotype correlations.

    PubMed

    Ricard, Emilie; Mathis, Stéphane; Magdelaine, Corinne; Delisle, Marie-Bernadette; Magy, Laurent; Funalot, Benoît; Vallat, Jean-Michel

    2013-09-01

    Charcot-Marie-Tooth (CMT) disease is a heterogeneous condition with a large number of clinical, electrophysiological and pathological phenotypes. More than 40 genes are involved. We report a child of gypsy origin with an autosomal recessive demyelinating phenotype. Clinical data, familial history, and electrophysiological studies were in favor of a CMT4 sub-type. The characteristic N-Myc downstream-regulated gene 1 (NDRG1) mutation responsible for this CMT4D phenotype was confirmed: p.R148X. The exact molecular function of the NDRG1 protein has yet to be elucidated.

  1. 4D Flow MRI in Neuroradiology: Techniques and Applications.

    PubMed

    Pereira, Vitor Mendes; Delattre, Benedicte; Brina, Olivier; Bouillot, Pierre; Vargas, Maria Isabel

    2016-04-01

    Assessment of the intracranial flow is important for the understanding and management of cerebral vascular diseases. From brain aneurysms and arteriovenous malformations lesions to intracranial and cervical stenosis, the appraisal of the blood flow can be crucial and influence positively on patients' management. The determination of the intracranial hemodynamics and the collateral pattern seems to play to a major role in the management of these lesions. 4D flow magnetic resonance imaging is a noninvasive phase contrast derived method that has been developed and applied in neurovascular diseases. It has a great potential if followed by further technical improvements and comprehensive and systematic clinical studies.

  2. Oblique sounding using the DPS-4D stations in Europe

    NASA Astrophysics Data System (ADS)

    Mosna, Zbysek; Kouba, Daniel; Koucka Knizova, Petra; Arikan, Feza; Arikan, Orhan; Gok, Gokhan; Rejfek, Lubos

    2016-07-01

    The DPS-4D Digisondes are capable of detection of echoes from neighbouring European stations. Currently, a campaign with high-temporal resolution of 5 min is being run. Further, ionograms from regular vertical sounding with 15 min resolution provide us with oblique reflections together with vertical reflections. We analyzed profiles of electron concentration and basic ionospheric parameters derived from the ionograms. We compared results derived from reflections from the ionosphere above the stations (vertical sounding) with information derived from oblique reflections between the stations. This study is supported by the Joint TUBITAK 114E092 and AS CR 14/001 projects.

  3. Founding Gravitation in 4D Euclidean Space-Time Geometry

    SciTech Connect

    Winkler, Franz-Guenter

    2010-11-24

    The Euclidean interpretation of special relativity which has been suggested by the author is a formulation of special relativity in ordinary 4D Euclidean space-time geometry. The natural and geometrically intuitive generalization of this view involves variations of the speed of light (depending on location and direction) and a Euclidean principle of general covariance. In this article, a gravitation model by Jan Broekaert, which implements a view of relativity theory in the spirit of Lorentz and Poincare, is reconstructed and shown to fulfill the principles of the Euclidean approach after an appropriate reinterpretation.

  4. Complications in CT-guided Procedures: Do We Really Need Postinterventional CT Control Scans?

    SciTech Connect

    Nattenmüller, Johanna Filsinger, Matthias Bryant, Mark Stiller, Wolfram Radeleff, Boris Grenacher, Lars Kauczor, Hans-Ullrich Hosch, Waldemar

    2013-06-19

    PurposeThe aim of this study is twofold: to determine the complication rate in computed tomography (CT)-guided biopsies and drainages, and to evaluate the value of postinterventional CT control scans.MethodsRetrospective analysis of 1,067 CT-guided diagnostic biopsies (n = 476) and therapeutic drainages (n = 591) in thoracic (n = 37), abdominal (n = 866), and musculoskeletal (ms) (n = 164) locations. Severity of any complication was categorized as minor or major. To assess the need for postinterventional CT control scans, it was determined whether complications were detected clinically, on peri-procedural scans or on postinterventional scans only.ResultsThe complication rate was 2.5 % in all procedures (n = 27), 4.4 % in diagnostic punctures, and 1.0 % in drainages; 13.5 % in thoracic, 2.0 % in abdominal, and 3.0 % in musculoskeletal procedures. There was only 1 major complication (0.1 %). Pneumothorax (n = 14) was most frequent, followed by bleeding (n = 9), paresthesia (n = 2), material damage (n = 1), and bone fissure (n = 1). Postinterventional control acquisitions were performed in 65.7 % (701 of 1,067). Six complications were solely detectable in postinterventional control acquisitions (3 retroperitoneal bleeds, 3 pneumothoraces); all other complications were clinically detectable (n = 4) and/or visible in peri-interventional controls (n = 21).ConclusionComplications in CT-guided interventions are rare. Of these, thoracic interventions had the highest rate, while pneumothoraces and bleeding were most frequent. Most complications can be detected clinically or peri-interventionally. To reduce the radiation dose, postinterventional CT controls should not be performed routinely and should be restricted to complicated or retroperitoneal interventions only.

  5. Evaluation of intrinsic respiratory signal determination methods for 4D CBCT adapted for mice

    SciTech Connect

    Martin, Rachael; Pan, Tinsu; Rubinstein, Ashley; Court, Laurence; Ahmad, Moiz

    2015-01-15

    Purpose: 4D CT imaging in mice is important in a variety of areas including studies of lung function and tumor motion. A necessary step in 4D imaging is obtaining a respiratory signal, which can be done through an external system or intrinsically through the projection images. A number of methods have been developed that can successfully determine the respiratory signal from cone-beam projection images of humans, however only a few have been utilized in a preclinical setting and most of these rely on step-and-shoot style imaging. The purpose of this work is to assess and make adaptions of several successful methods developed for humans for an image-guided preclinical radiation therapy system. Methods: Respiratory signals were determined from the projection images of free-breathing mice scanned on the X-RAD system using four methods: the so-called Amsterdam shroud method, a method based on the phase of the Fourier transform, a pixel intensity method, and a center of mass method. The Amsterdam shroud method was modified so the sharp inspiration peaks associated with anesthetized mouse breathing could be detected. Respiratory signals were used to sort projections into phase bins and 4D images were reconstructed. Error and standard deviation in the assignment of phase bins for the four methods compared to a manual method considered to be ground truth were calculated for a range of region of interest (ROI) sizes. Qualitative comparisons were additionally made between the 4D images obtained using each of the methods and the manual method. Resu