  1. Quantifying the impact of respiratory-gated 4D CT acquisition on thoracic image quality: A digital phantom study

    SciTech Connect

    Bernatowicz, K. Knopf, A.; Lomax, A.; Keall, P.; Kipritidis, J.; Mishra, P.

    2015-01-15

    Purpose: Prospective respiratory-gated 4D CT has been shown to reduce tumor image artifacts by up to 50% compared to conventional 4D CT. However, to date no studies have quantified the impact of gated 4D CT on normal lung tissue imaging, which is important in performing dose calculations based on accurate estimates of lung volume and structure. To determine the impact of gated 4D CT on thoracic image quality, the authors developed a novel simulation framework incorporating a realistic deformable digital phantom driven by patient tumor motion patterns. Based on this framework, the authors test the hypothesis that respiratory-gated 4D CT can significantly reduce lung imaging artifacts. Methods: Our simulation framework synchronizes the 4D extended cardiac torso (XCAT) phantom with tumor motion data in a quasi real-time fashion, allowing simulation of three 4D CT acquisition modes featuring different levels of respiratory feedback: (i) “conventional” 4D CT that uses a constant imaging and couch-shift frequency, (ii) “beam paused” 4D CT that interrupts imaging to avoid oversampling at a given couch position and respiratory phase, and (iii) “respiratory-gated” 4D CT that triggers acquisition only when the respiratory motion fulfills phase-specific displacement gating windows based on prescan breathing data. Our framework generates a set of ground truth comparators, representing the average XCAT anatomy during beam-on for each of ten respiratory phase bins. Based on this framework, the authors simulated conventional, beam-paused, and respiratory-gated 4D CT images using tumor motion patterns from seven lung cancer patients across 13 treatment fractions, with a simulated 5.5 cm{sup 3} spherical lesion. Normal lung tissue image quality was quantified by comparing simulated and ground truth images in terms of overall mean square error (MSE) intensity difference, threshold-based lung volume error, and fractional false positive/false negative rates. Results

  2. SU-E-J-241: Creation of Ventilation CT From Daily 4D CTs Or 4D Conebeam CTs Acquired During IGRT for Thoracic Cancers

    SciTech Connect

    Tai, A; Ahunbay, E; Li, X

    2014-06-01

    Purpose: To develop a method to create ventilation CTs from daily 4D CTs or 4D KV conebeam CTs (4DCBCT) acquired during image-guided radiation therapy (IGRT) for thoracic tumors, and to explore the potential for using the ventilation CTs as a means for early detection of lung injury during radiation treatment. Methods: 4DCT acquired using an in-room CT (CTVision, Siemens) and 4DCBCT acquired using the X-ray Volume Imaging (XVI) system (Infinity, Elekta) for representative lung cancer patients were analyzed. These 4D data sets were sorted into 10 phase images. A newly-available deformable image registration tool (ADMIRE, Elekta) is used to deform the phase images at the end of exhale (EE) to the phase images at the end of inhale (EI). The lung volumes at EI and EE were carefully contoured using an intensity-based auto-contour tool and then manually edited. The ventilation images were calculated from the variations of CT numbers of those voxels masked by the lung contour at EI between the registered phase images. The deformable image registration is also performed between the daily 4D images and planning 4DCT, and the resulting deformable field vector (DFV) is used to deform the planning doses to the daily images by an in-house Matlab program. Results: The ventilation images were successfully created. The tide volumes calculated using the ventilation images agree with those measured through volume difference of contours at EE and EI, indicating the accuracy of ventilation images. The association between the delivered doses and the change of lung ventilation from the daily ventilation CTs is identified. Conclusions: A method to create the ventilation CT using daily 4DCTs or 4D KV conebeam CTs was developed and demonstrated.

  3. IMRT treatment plans and functional planning with functional lung imaging from 4D-CT for thoracic cancer patients

    PubMed Central

    2013-01-01

    Background and purpose Currently, the inhomogeneity of the pulmonary function is not considered when treatment plans are generated in thoracic cancer radiotherapy. This study evaluates the dose of treatment plans on highly-functional volumes and performs functional treatment planning by incorporation of ventilation data from 4D-CT. Materials and methods Eleven patients were included in this retrospective study. Ventilation was calculated using 4D-CT. Two treatment plans were generated for each case, the first one without the incorporation of the ventilation and the second with it. The dose of the first plans was overlapped with the ventilation and analyzed. Highly-functional regions were avoided in the second treatment plans. Results For small targets in the first plans (PTV < 400 cc, 6 cases), all V5, V20 and the mean lung dose values for the highly-functional regions were lower than that of the total lung. For large targets, two out of five cases had higher V5 and V20 values for the highly-functional regions. All the second plans were within constraints. Conclusion Radiation treatments affect functional lung more seriously in large tumor cases. With compromise of dose to other critical organs, functional treatment planning to reduce dose in highly-functional lung volumes can be achieved PMID:23281734

  4. Beam-specific planning target volumes incorporating 4D CT for pencil beam scanning proton therapy of thoracic tumors.

    PubMed

    Lin, Liyong; Kang, Minglei; Huang, Sheng; Mayer, Rulon; Thomas, Andrew; Solberg, Timothy D; McDonough, James E; Simone, Charles B

    2015-11-08

    The purpose of this study is to determine whether organ sparing and target coverage can be simultaneously maintained for pencil beam scanning (PBS) proton therapy treatment of thoracic tumors in the presence of motion, stopping power uncertainties, and patient setup variations. Ten consecutive patients that were previously treated with proton therapy to 66.6/1.8 Gy (RBE) using double scattering (DS) were replanned with PBS. Minimum and maximum intensity images from 4D CT were used to introduce flexible smearing in the determination of the beam specific PTV (BSPTV). Datasets from eight 4D CT phases, using ± 3% uncertainty in stopping power and ± 3 mm uncertainty in patient setup in each direction, were used to create 8 × 12 × 10 = 960 PBS plans for the evaluation of 10 patients. Plans were normalized to provide identical coverage between DS and PBS. The average lung V20, V5, and mean doses were reduced from 29.0%, 35.0%, and 16.4 Gy with DS to 24.6%, 30.6%, and 14.1 Gy with PBS, respectively. The average heart V30 and V45 were reduced from 10.4% and 7.5% in DS to 8.1% and 5.4% for PBS, respectively. Furthermore, the maximum spinal cord, esophagus, and heart doses were decreased from 37.1 Gy, 71.7 Gy, and 69.2 Gy with DS to 31.3 Gy, 67.9 Gy, and 64.6 Gy with PBS. The conformity index (CI), homogeneity index (HI), and global maximal dose were improved from 3.2, 0.08, 77.4 Gy with DS to 2.8, 0.04, and 72.1 Gy with PBS. All differences are statistically significant, with p-values <0.05, with the exception of the heart V45 (p = 0.146). PBS with BSPTV achieves better organ sparing and improves target coverage using a repainting method for the treatment of thoracic tumors. Incorporating motion-related uncertainties is essential.

  5. Beam-specific planning target volumes incorporating 4D CT for pencil beam scanning proton therapy of thoracic tumors.

    PubMed

    Lin, Liyong; Kang, Minglei; Huang, Sheng; Mayer, Rulon; Thomas, Andrew; Solberg, Timothy D; McDonough, James E; Simone, Charles B

    2015-01-01

    The purpose of this study is to determine whether organ sparing and target coverage can be simultaneously maintained for pencil beam scanning (PBS) proton therapy treatment of thoracic tumors in the presence of motion, stopping power uncertainties, and patient setup variations. Ten consecutive patients that were previously treated with proton therapy to 66.6/1.8 Gy (RBE) using double scattering (DS) were replanned with PBS. Minimum and maximum intensity images from 4D CT were used to introduce flexible smearing in the determination of the beam specific PTV (BSPTV). Datasets from eight 4D CT phases, using ± 3% uncertainty in stopping power and ± 3 mm uncertainty in patient setup in each direction, were used to create 8 × 12 × 10 = 960 PBS plans for the evaluation of 10 patients. Plans were normalized to provide identical coverage between DS and PBS. The average lung V20, V5, and mean doses were reduced from 29.0%, 35.0%, and 16.4 Gy with DS to 24.6%, 30.6%, and 14.1 Gy with PBS, respectively. The average heart V30 and V45 were reduced from 10.4% and 7.5% in DS to 8.1% and 5.4% for PBS, respectively. Furthermore, the maximum spinal cord, esophagus, and heart doses were decreased from 37.1 Gy, 71.7 Gy, and 69.2 Gy with DS to 31.3 Gy, 67.9 Gy, and 64.6 Gy with PBS. The conformity index (CI), homogeneity index (HI), and global maximal dose were improved from 3.2, 0.08, 77.4 Gy with DS to 2.8, 0.04, and 72.1 Gy with PBS. All differences are statistically significant, with p-values <0.05, with the exception of the heart V45 (p = 0.146). PBS with BSPTV achieves better organ sparing and improves target coverage using a repainting method for the treatment of thoracic tumors. Incorporating motion-related uncertainties is essential. PMID:26699580

  6. Usefulness of four dimensional (4D) PET/CT imaging in the evaluation of thoracic lesions and in radiotherapy planning: Review of the literature.

    PubMed

    Sindoni, Alessandro; Minutoli, Fabio; Pontoriero, Antonio; Iatì, Giuseppe; Baldari, Sergio; Pergolizzi, Stefano

    2016-06-01

    In the past decade, Positron Emission Tomography (PET) has become a routinely used methodology for the assessment of solid tumors, which can detect functional abnormalities even before they become morphologically evident on conventional imaging. PET imaging has been reported to be useful in characterizing solitary pulmonary nodules, guiding biopsy, improving lung cancer staging, guiding therapy, monitoring treatment response and predicting outcome. This review focuses on the most relevant and recent literature findings, highlighting the current role of PET/CT and the evaluation of 4D-PET/CT modality for radiation therapy planning applications. Current evidence suggests that gross tumor volume delineation based on 4D-PET/CT information may be the best approach currently available for its delineation in thoracic cancers (lung and non-lung lesions). In our opinion, its use in this clinical setting is strongly encouraged, as it may improve patient treatment outcome in the setting of radiation therapy for cancers of the thoracic region, not only involving lung, but also lymph nodes and esophageal tissue. Literature results warrants further investigation in future prospective studies, especially in the setting of dose escalation. PMID:27133755

  7. Image quality in thoracic 4D cone-beam CT: A sensitivity analysis of respiratory signal, binning method, reconstruction algorithm, and projection angular spacing

    SciTech Connect

    Shieh, Chun-Chien; Kipritidis, John; O’Brien, Ricky T.; Keall, Paul J.; Kuncic, Zdenka

    2014-04-15

    Purpose: Respiratory signal, binning method, and reconstruction algorithm are three major controllable factors affecting image quality in thoracic 4D cone-beam CT (4D-CBCT), which is widely used in image guided radiotherapy (IGRT). Previous studies have investigated each of these factors individually, but no integrated sensitivity analysis has been performed. In addition, projection angular spacing is also a key factor in reconstruction, but how it affects image quality is not obvious. An investigation of the impacts of these four factors on image quality can help determine the most effective strategy in improving 4D-CBCT for IGRT. Methods: Fourteen 4D-CBCT patient projection datasets with various respiratory motion features were reconstructed with the following controllable factors: (i) respiratory signal (real-time position management, projection image intensity analysis, or fiducial marker tracking), (ii) binning method (phase, displacement, or equal-projection-density displacement binning), and (iii) reconstruction algorithm [Feldkamp–Davis–Kress (FDK), McKinnon–Bates (MKB), or adaptive-steepest-descent projection-onto-convex-sets (ASD-POCS)]. The image quality was quantified using signal-to-noise ratio (SNR), contrast-to-noise ratio, and edge-response width in order to assess noise/streaking and blur. The SNR values were also analyzed with respect to the maximum, mean, and root-mean-squared-error (RMSE) projection angular spacing to investigate how projection angular spacing affects image quality. Results: The choice of respiratory signals was found to have no significant impact on image quality. Displacement-based binning was found to be less prone to motion artifacts compared to phase binning in more than half of the cases, but was shown to suffer from large interbin image quality variation and large projection angular gaps. Both MKB and ASD-POCS resulted in noticeably improved image quality almost 100% of the time relative to FDK. In addition, SNR

  8. Thoracic textilomas: CT findings*

    PubMed Central

    Machado, Dianne Melo; Zanetti, Gláucia; Araujo, Cesar Augusto; Nobre, Luiz Felipe; Meirelles, Gustavo de Souza Portes; Pereira e Silva, Jorge Luiz; Guimarães, Marcos Duarte; Escuissato, Dante Luiz; Souza, Arthur Soares; Hochhegger, Bruno; Marchiori, Edson

    2014-01-01

    OBJECTIVE: The aim of this study was to analyze chest CT scans of patients with thoracic textiloma. METHODS: This was a retrospective study of 16 patients (11 men and 5 women) with surgically confirmed thoracic textiloma. The chest CT scans of those patients were evaluated by two independent observers, and discordant results were resolved by consensus. RESULTS: The majority (62.5%) of the textilomas were caused by previous heart surgery. The most common symptoms were chest pain (in 68.75%) and cough (in 56.25%). In all cases, the main tomographic finding was a mass with regular contours and borders that were well-defined or partially defined. Half of the textilomas occurred in the right hemithorax and half occurred in the left. The majority (56.25%) were located in the lower third of the lung. The diameter of the mass was ≤ 10 cm in 10 cases (62.5%) and > 10 cm in the remaining 6 cases (37.5%). Most (81.25%) of the textilomas were heterogeneous in density, with signs of calcification, gas, radiopaque marker, or sponge-like material. Peripheral expansion of the mass was observed in 12 (92.3%) of the 13 patients in whom a contrast agent was used. Intraoperatively, pleural involvement was observed in 14 cases (87.5%) and pericardial involvement was observed in 2 (12.5%). CONCLUSIONS: It is important to recognize the main tomographic aspects of thoracic textilomas in order to include this possibility in the differential diagnosis of chest pain and cough in patients with a history of heart or thoracic surgery, thus promoting the early identification and treatment of this postoperative complication. PMID:25410842

  9. Helical 4D CT and Comparison with Cine 4D CT

    NASA Astrophysics Data System (ADS)

    Pan, Tinsu

    4D CT was one of the most important developments in radiation oncology in the last decade. Its early development in single slice CT and commercialization in multi-slice CT has radically changed our practice in radiation treatment of lung cancer, and has enabled the stereotactic radiosurgery of early stage lung cancer. In this chapter, we will document the history of 4D CT development, detail the data sufficiency condition governing the 4D CT data collection; present the design of the commercial helical 4D CTs from Philips and Siemens; compare the differences between the helical 4D CT and the GE cine 4D CT in data acquisition, slice thickness, acquisition time and work flow; review the respiratory monitoring devices; and understand the causes of image artifacts in 4D CT.

  10. Abdominal and pancreatic motion correlation using 4D CT, 4D transponders, and a gating belt.

    PubMed

    Betancourt, Ricardo; Zou, Wei; Plastaras, John P; Metz, James M; Teo, Boon-Keng; Kassaee, Alireza

    2013-01-01

    The correlation between the pancreatic and external abdominal motion due to respiration was investigated on two patients. These studies utilized four dimensional computer tomography (4D CT), a four dimensional (4D) electromagnetic transponder system, and a gating belt system. One 4D CT study was performed during simulation to quantify the pancreatic motion using computer tomography images at eight breathing phases. The motion under free breathing and breath-hold were analyzed for the 4D electromagnetic transponder system and the gating belt system during treatment. A linear curve was fitted for all data sets and correlation factors were evaluated between the 4D electromagnetic transponder system and the gating belt system data. The 4D CT study demonstrated a modest correlation between the external marker and the pancreatic motion with R-square values larger than 0.8 for the inferior-superior (inf-sup). Then, the relative pressure from the belt gating system correlated well with the 4D electromagnetic transponder system's motion in the anterior-posterior (ant-post) and the inf-post directions. These directions have a correlation value of -0.93 and 0.76, while the lateral only had a 0.03 correlation coefficient. Based on our limited study, external surrogates can be used as predictors of the pancreatic motion in the inf-sup and the ant-post directions. Although there is a low correlation on the lateral direction, its motion is significantly shorter. In conclusion, an appropriate treatment delivery can be used for pancreatic cancer when an internal tracking system, such as the 4D electromagnetic transponder system, is unavailable. PMID:23652242

  11. Abdominal and pancreatic motion correlation using 4D CT, 4D transponders, and a gating belt.

    PubMed

    Betancourt, Ricardo; Zou, Wei; Plastaras, John P; Metz, James M; Teo, Boon-Keng; Kassaee, Alireza

    2013-05-06

    The correlation between the pancreatic and external abdominal motion due to respiration was investigated on two patients. These studies utilized four dimensional computer tomography (4D CT), a four dimensional (4D) electromagnetic transponder system, and a gating belt system. One 4D CT study was performed during simulation to quantify the pancreatic motion using computer tomography images at eight breathing phases. The motion under free breathing and breath-hold were analyzed for the 4D electromagnetic transponder system and the gating belt system during treatment. A linear curve was fitted for all data sets and correlation factors were evaluated between the 4D electromagnetic transponder system and the gating belt system data. The 4D CT study demonstrated a modest correlation between the external marker and the pancreatic motion with R-square values larger than 0.8 for the inferior-superior (inf-sup). Then, the relative pressure from the belt gating system correlated well with the 4D electromagnetic transponder system's motion in the anterior-posterior (ant-post) and the inf-post directions. These directions have a correlation value of -0.93 and 0.76, while the lateral only had a 0.03 correlation coefficient. Based on our limited study, external surrogates can be used as predictors of the pancreatic motion in the inf-sup and the ant-post directions. Although there is a low correlation on the lateral direction, its motion is significantly shorter. In conclusion, an appropriate treatment delivery can be used for pancreatic cancer when an internal tracking system, such as the 4D electromagnetic transponder system, is unavailable.

  12. Evaluation of 4D CT acquisition methods designed to reduce artifacts.

    PubMed

    Castillo, Sarah J; Castillo, Richard; Castillo, Edward; Pan, Tinsu; Ibbott, Geoffrey; Balter, Peter; Hobbs, Brian; Guerrero, Thomas

    2015-03-08

    Four-dimensional computed tomography (4D CT) is used to account for respiratory motion in radiation treatment planning, but artifacts resulting from the acquisition and postprocessing limit its accuracy. We investigated the efficacy of three experimental 4D CT acquisition methods to reduce artifacts in a prospective institutional review board approved study. Eighteen thoracic patients scheduled to undergo radiation therapy received standard clinical 4D CT scans followed by each of the alternative 4D CT acquisitions: 1) data oversampling, 2) beam gating with breathing irregularities, and 3) rescanning the clinical acquisition acquired during irregular breathing. Relative values of a validated correlation-based artifact metric (CM) determined the best acquisition method per patient. Each 4D CT was processed by an extended phase sorting approach that optimizes the quantitative artifact metric (CM sorting). The clinical acquisitions were also postprocessed by phase sorting for artifact comparison of our current clinical implementation with the experimental methods. The oversampling acquisition achieved the lowest artifact presence among all acquisitions, achieving a 27% reduction from the current clinical 4D CT implementation (95% confidence interval = 34-20). The rescan method presented a significantly higher artifact presence from the clinical acquisition (37%; p < 0.002), the gating acquisition (26%; p < 0.005), and the oversampling acquisition (31%; p < 0.001), while the data lacked evidence of a significant difference between the clinical, gating, and oversampling methods. The oversampling acquisition reduced artifact presence from the current clinical 4D CT implementation to the largest degree and provided the simplest and most reproducible implementation. The rescan acquisition increased artifact presence significantly, compared to all acquisitions, and suffered from combination of data from independent scans over which large internal anatomic shifts occurred.

  13. Evaluation of a 4D cone-beam CT reconstruction approach using a simulation framework.

    PubMed

    Hartl, Alexander; Yaniv, Ziv

    2009-01-01

    Current image-guided navigation systems for thoracic abdominal interventions utilize three dimensional (3D) images acquired at breath-hold. As a result they can only provide guidance at a specific point in the respiratory cycle. The intervention is thus performed in a gated manner, with the physician advancing only when the patient is at the same respiratory cycle in which the 3D image was acquired. To enable a more continuous workflow we propose to use 4D image data. We describe an approach to constructing a set of 4D images from a diagnostic CT acquired at breath-hold and a set of intraoperative cone-beam CT (CBCT) projection images acquired while the patient is freely breathing. Our approach is based on an initial reconstruction of a gated 4D CBCT data set. The 3D CBCT images for each respiratory phase are then non-rigidly registered to the diagnostic CT data. Finally the diagnostic CT is deformed based on the registration results, providing a 4D data set with sufficient quality for navigation purposes. In this work we evaluate the proposed reconstruction approach using a simulation framework. A 3D CBCT dataset of an anthropomorphic phantom is deformed using internal motion data acquired from an animal model to create a ground truth 4D CBCT image. Simulated projection images are then created from the 4D image and the known CBCT scan parameters. Finally, the original 3D CBCT and the simulated X-ray images are used as input to our reconstruction method. The resulting 4D data set is then compared to the known ground truth by normalized cross correlation(NCC). We show that the deformed diagnostic CTs are of better quality than the gated reconstructions with a mean NCC value of 0.94 versus a mean 0.81 for the reconstructions. PMID:19964143

  14. Improvement of the cine-CT based 4D-CT imaging

    SciTech Connect

    Pan Tinsu; Sun Xiaojun; Luo Dershan

    2007-11-15

    An improved 4D-CT utility has been developed on the GE LightSpeed multislice CT (MSCT) and Discovery PET/CT scanners, which have the cine CT scan capability. Two new features have been added in this 4D-CT over the commercial Advantage 4D-CT from GE. One feature was a new tool for disabling parts of the respiratory signal with irregular respiration and improving the accuracy of phase determination for the respiratory signal from the Varian real-time positioning and monitoring (RPM) system before sorting of the cine CT images into the 4D-CT images. The second feature was to allow generation of the maximum-intensity-projection (MIP), average (AVG) and minimum-intensity-projection (mip) CT images from the cine CT images without a respiratory signal. The implementation enables the assessment of tumor motion in treatment planning with the MIP, AVG, and mip CT images on the GE MSCT and PET/CT scanners without the RPM and the Advantage 4D-CT with a GE Advantage windows workstation. Several clinical examples are included to illustrate this new application.

  15. 4D micro-CT using fast prospective gating

    NASA Astrophysics Data System (ADS)

    Guo, Xiaolian; Johnston, Samuel M.; Qi, Yi; Johnson, G. Allan; Badea, Cristian T.

    2012-01-01

    Micro-CT is currently used in preclinical studies to provide anatomical information. But, there is also significant interest in using this technology to obtain functional information. We report here a new sampling strategy for 4D micro-CT for functional cardiac and pulmonary imaging. Rapid scanning of free-breathing mice is achieved with fast prospective gating (FPG) implemented on a field programmable gate array. The method entails on-the-fly computation of delays from the R peaks of the ECG signals or the peaks of the respiratory signals for the triggering pulses. Projection images are acquired for all cardiac or respiratory phases at each angle before rotating to the next angle. FPG can deliver the faster scan time of retrospective gating (RG) with the regular angular distribution of conventional prospective gating for cardiac or respiratory gating. Simultaneous cardio-respiratory gating is also possible with FPG in a hybrid retrospective/prospective approach. We have performed phantom experiments to validate the new sampling protocol and compared the results from FPG and RG in cardiac imaging of a mouse. Additionally, we have evaluated the utility of incorporating respiratory information in 4D cardiac micro-CT studies with FPG. A dual-source micro-CT system was used for image acquisition with pulsed x-ray exposures (80 kVp, 100 mA, 10 ms). The cardiac micro-CT protocol involves the use of a liposomal blood pool contrast agent containing 123 mg I ml-1 delivered via a tail vein catheter in a dose of 0.01 ml g-1 body weight. The phantom experiment demonstrates that FPG can distinguish the successive phases of phantom motion with minimal motion blur, and the animal study demonstrates that respiratory FPG can distinguish inspiration and expiration. 4D cardiac micro-CT imaging with FPG provides image quality superior to RG at an isotropic voxel size of 88 µm and 10 ms temporal resolution. The acquisition time for either sampling approach is less than 5 min. The

  16. Brain tissue segmentation in 4D CT using voxel classification

    NASA Astrophysics Data System (ADS)

    van den Boom, R.; Oei, M. T. H.; Lafebre, S.; Oostveen, L. J.; Meijer, F. J. A.; Steens, S. C. A.; Prokop, M.; van Ginneken, B.; Manniesing, R.

    2012-02-01

    A method is proposed to segment anatomical regions of the brain from 4D computer tomography (CT) patient data. The method consists of a three step voxel classification scheme, each step focusing on structures that are increasingly difficult to segment. The first step classifies air and bone, the second step classifies vessels and the third step classifies white matter, gray matter and cerebrospinal fluid. As features the time averaged intensity value and the temporal intensity change value were used. In each step, a k-Nearest-Neighbor classifier was used to classify the voxels. Training data was obtained by placing regions of interest in reconstructed 3D image data. The method has been applied to ten 4D CT cerebral patient data. A leave-one-out experiment showed consistent and accurate segmentation results.

  17. Phase and amplitude binning for 4D-CT imaging

    NASA Astrophysics Data System (ADS)

    Abdelnour, A. F.; Nehmeh, S. A.; Pan, T.; Humm, J. L.; Vernon, P.; Schöder, H.; Rosenzweig, K. E.; Mageras, G. S.; Yorke, E.; Larson, S. M.; Erdi, Y. E.

    2007-07-01

    We compare the consistency and accuracy of two image binning approaches used in 4D-CT imaging. One approach, phase binning (PB), assigns each breathing cycle 2π rad, within which the images are grouped. In amplitude binning (AB), the images are assigned bins according to the breathing signal's full amplitude. To quantitate both approaches we used a NEMA NU2-2001 IEC phantom oscillating in the axial direction and at random frequencies and amplitudes, approximately simulating a patient's breathing. 4D-CT images were obtained using a four-slice GE Lightspeed CT scanner operating in cine mode. We define consistency error as a measure of ability to correctly bin over repeated cycles in the same field of view. Average consistency error μe ± σe in PB ranged from 18% ± 20% to 30% ± 35%, while in AB the error ranged from 11% ± 14% to 20% ± 24%. In PB nearly all bins contained sphere slices. AB was more accurate, revealing empty bins where no sphere slices existed. As a proof of principle, we present examples of two non-small cell lung carcinoma patients' 4D-CT lung images binned by both approaches. While AB can lead to gaps in the coronal images, depending on the patient's breathing pattern, PB exhibits no gaps but suffers visible artifacts due to misbinning, yielding images that cover a relatively large amplitude range. AB was more consistent, though often resulted in gaps when no data existed due to patients' breathing pattern. We conclude AB is more accurate than PB. This has important consequences to treatment planning and diagnosis.

  18. TH-E-17A-07: Improved Cine Four-Dimensional Computed Tomography (4D CT) Acquisition and Processing Method

    SciTech Connect

    Castillo, S; Castillo, R; Castillo, E; Pan, T; Ibbott, G; Balter, P; Hobbs, B; Dai, J; Guerrero, T

    2014-06-15

    Purpose: Artifacts arising from the 4D CT acquisition and post-processing methods add systematic uncertainty to the treatment planning process. We propose an alternate cine 4D CT acquisition and post-processing method to consistently reduce artifacts, and explore patient parameters indicative of image quality. Methods: In an IRB-approved protocol, 18 patients with primary thoracic malignancies received a standard cine 4D CT acquisition followed by an oversampling 4D CT that doubled the number of images acquired. A second cohort of 10 patients received the clinical 4D CT plus 3 oversampling scans for intra-fraction reproducibility. The clinical acquisitions were processed by the standard phase sorting method. The oversampling acquisitions were processed using Dijkstras algorithm to optimize an artifact metric over available image data. Image quality was evaluated with a one-way mixed ANOVA model using a correlation-based artifact metric calculated from the final 4D CT image sets. Spearman correlations and a linear mixed model tested the association between breathing parameters, patient characteristics, and image quality. Results: The oversampling 4D CT scans reduced artifact presence significantly by 27% and 28%, for the first cohort and second cohort respectively. From cohort 2, the inter-replicate deviation for the oversampling method was within approximately 13% of the cross scan average at the 0.05 significance level. Artifact presence for both clinical and oversampling methods was significantly correlated with breathing period (ρ=0.407, p-value<0.032 clinical, ρ=0.296, p-value<0.041 oversampling). Artifact presence in the oversampling method was significantly correlated with amount of data acquired, (ρ=-0.335, p-value<0.02) indicating decreased artifact presence with increased breathing cycles per scan location. Conclusion: The 4D CT oversampling acquisition with optimized sorting reduced artifact presence significantly and reproducibly compared to the phase

  19. Complete valvular heart apparatus model from 4D cardiac CT.

    PubMed

    Grbic, Sasa; Ionasec, Razvan; Vitanovski, Dime; Voigt, Ingmar; Wang, Yang; Georgescu, Bogdan; Navab, Nassir; Comaniciu, Dorin

    2012-07-01

    The cardiac valvular apparatus, composed of the aortic, mitral, pulmonary and tricuspid valves, is an essential part of the anatomical, functional and hemodynamic characteristics of the heart and the cardiovascular system as a whole. Valvular heart diseases often involve multiple dysfunctions and require joint assessment and therapy of the valves. In this paper, we propose a complete and modular patient-specific model of the cardiac valvular apparatus estimated from 4D cardiac CT data. A new constrained Multi-linear Shape Model (cMSM), conditioned by anatomical measurements, is introduced to represent the complex spatio-temporal variation of the heart valves. The cMSM is exploited within a learning-based framework to efficiently estimate the patient-specific valve parameters from cine images. Experiments on 64 4D cardiac CT studies demonstrate the performance and clinical potential of the proposed method. Our method enables automatic quantitative evaluation of the complete valvular apparatus based on non-invasive imaging techniques. In conjunction with existent patient-specific chamber models, the presented valvular model enables personalized computation modeling and realistic simulation of the entire cardiac system.

  20. Motion artifacts occurring at the lung/diaphragm interface using 4D CT attenuation correction of 4D PET scans.

    PubMed

    Killoran, Joseph H; Gerbaudo, Victor H; Mamede, Marcelo; Ionascu, Dan; Park, Sang-June; Berbeco, Ross

    2011-11-15

    For PET/CT, fast CT acquisition time can lead to errors in attenuation correction, particularly at the lung/diaphragm interface. Gated 4D PET can reduce motion artifacts, though residual artifacts may persist depending on the CT dataset used for attenuation correction. We performed phantom studies to evaluate 4D PET images of targets near a density interface using three different methods for attenuation correction: a single 3D CT (3D CTAC), an averaged 4D CT (CINE CTAC), and a fully phase matched 4D CT (4D CTAC). A phantom was designed with two density regions corresponding to diaphragm and lung. An 8 mL sphere phantom loaded with 18F-FDG was used to represent a lung tumor and background FDG included at an 8:1 ratio. Motion patterns of sin(x) and sin4(x) were used for dynamic studies. Image data was acquired using a GE Discovery DVCT-PET/CT scanner. Attenuation correction methods were compared based on normalized recovery coefficient (NRC), as well as a novel quantity "fixed activity volume" (FAV) introduced in our report. Image metrics were compared to those determined from a 3D PET scan with no motion present (3D STATIC). Values of FAV and NRC showed significant variation over the motion cycle when corrected by 3D CTAC images. 4D CTAC- and CINE CTAC-corrected PET images reduced these motion artifacts. The amount of artifact reduction is greater when the target is surrounded by lower density material and when motion was based on sin4(x). 4D CTAC reduced artifacts more than CINE CTAC for most scenarios. For a target surrounded by water equivalent material, there was no advantage to 4D CTAC over CINE CTAC when using the sin(x) motion pattern. Attenuation correction using both 4D CTAC or CINE CTAC can reduce motion artifacts in regions that include a tissue interface such as the lung/diaphragm border. 4D CTAC is more effective than CINE CTAC at reducing artifacts in some, but not all, scenarios.

  1. Impact of CT attenuation correction method on quantitative respiratory-correlated (4D) PET/CT imaging

    SciTech Connect

    Nyflot, Matthew J.; Lee, Tzu-Cheng; Alessio, Adam M.; Kinahan, Paul E.; Wollenweber, Scott D.; Stearns, Charles W.; Bowen, Stephen R.

    2015-01-15

    Purpose: Respiratory-correlated positron emission tomography (PET/CT) 4D PET/CT is used to mitigate errors from respiratory motion; however, the optimal CT attenuation correction (CTAC) method for 4D PET/CT is unknown. The authors performed a phantom study to evaluate the quantitative performance of CTAC methods for 4D PET/CT in the ground truth setting. Methods: A programmable respiratory motion phantom with a custom movable insert designed to emulate a lung lesion and lung tissue was used for this study. The insert was driven by one of five waveforms: two sinusoidal waveforms or three patient-specific respiratory waveforms. 3DPET and 4DPET images of the phantom under motion were acquired and reconstructed with six CTAC methods: helical breath-hold (3DHEL), helical free-breathing (3DMOT), 4D phase-averaged (4DAVG), 4D maximum intensity projection (4DMIP), 4D phase-matched (4DMATCH), and 4D end-exhale (4DEXH) CTAC. Recovery of SUV{sub max}, SUV{sub mean}, SUV{sub peak}, and segmented tumor volume was evaluated as RC{sub max}, RC{sub mean}, RC{sub peak}, and RC{sub vol}, representing percent difference relative to the static ground truth case. Paired Wilcoxon tests and Kruskal–Wallis ANOVA were used to test for significant differences. Results: For 4DPET imaging, the maximum intensity projection CTAC produced significantly more accurate recovery coefficients than all other CTAC methods (p < 0.0001 over all metrics). Over all motion waveforms, ratios of 4DMIP CTAC recovery were 0.2 ± 5.4, −1.8 ± 6.5, −3.2 ± 5.0, and 3.0 ± 5.9 for RC{sub max}, RC{sub peak}, RC{sub mean}, and RC{sub vol}. In comparison, recovery coefficients for phase-matched CTAC were −8.4 ± 5.3, −10.5 ± 6.2, −7.6 ± 5.0, and −13.0 ± 7.7 for RC{sub max}, RC{sub peak}, RC{sub mean}, and RC{sub vol}. When testing differences between phases over all CTAC methods and waveforms, end-exhale phases were significantly more accurate (p = 0.005). However, these differences were driven by

  2. Fast X-ray micro-CT for real-time 4D observation

    NASA Astrophysics Data System (ADS)

    Takano, H.; Yoshida, K.; Tsuji, T.; Koyama, T.; Tsusaka, Y.; Kagoshima, Y.

    2009-09-01

    Fast X-ray computed tomography (CT) system with sub-second order measurement for single CT acquisition has been developed. The system, consisting of a high-speed sample rotation stage and a high-speed X-ray camera, is constructed at synchrotron radiation beamline in order to utilize fully intense X-rays. A time-resolving CT movie (i.e. 4D CT) can be available by operating the fast CT system continuously. Real-time observation of water absorbing process of super-absorbent polymer (SAP) has been successfully performed with the 4D CT operation.

  3. Mapping motion from 4D-MRI to 3D-CT for use in 4D dose calculations: A technical feasibility study

    SciTech Connect

    Boye, Dirk; Lomax, Tony; Knopf, Antje

    2013-06-15

    Purpose: Target sites affected by organ motion require a time resolved (4D) dose calculation. Typical 4D dose calculations use 4D-CT as a basis. Unfortunately, 4D-CT images have the disadvantage of being a 'snap-shot' of the motion during acquisition and of assuming regularity of breathing. In addition, 4D-CT acquisitions involve a substantial additional dose burden to the patient making many, repeated 4D-CT acquisitions undesirable. Here the authors test the feasibility of an alternative approach to generate patient specific 4D-CT data sets. Methods: In this approach motion information is extracted from 4D-MRI. Simulated 4D-CT data sets [which the authors call 4D-CT(MRI)] are created by warping extracted deformation fields to a static 3D-CT data set. The employment of 4D-MRI sequences for this has the advantage that no assumptions on breathing regularity are made, irregularities in breathing can be studied and, if necessary, many repeat imaging studies (and consequently simulated 4D-CT data sets) can be performed on patients and/or volunteers. The accuracy of 4D-CT(MRI)s has been validated by 4D proton dose calculations. Our 4D dose algorithm takes into account displacements as well as deformations on the originating 4D-CT/4D-CT(MRI) by calculating the dose of each pencil beam based on an individual time stamp of when that pencil beam is applied. According to corresponding displacement and density-variation-maps the position and the water equivalent range of the dose grid points is adjusted at each time instance. Results: 4D dose distributions, using 4D-CT(MRI) data sets as input were compared to results based on a reference conventional 4D-CT data set capturing similar motion characteristics. Almost identical 4D dose distributions could be achieved, even though scanned proton beams are very sensitive to small differences in the patient geometry. In addition, 4D dose calculations have been performed on the same patient, but using 4D-CT(MRI) data sets based on

  4. Quantitative Analysis of Vortical Blood Flow in the Thoracic Aorta Using 4D Phase Contrast MRI

    PubMed Central

    von Spiczak, Jochen; Crelier, Gerard; Giese, Daniel; Kozerke, Sebastian; Maintz, David; Bunck, Alexander Christian

    2015-01-01

    4D phase contrast MRI. Vortex blood flow in the thoracic aorta could be consistently described in all healthy volunteers. In patient data, pathologically altered vortex flow was observed. PMID:26418327

  5. Four-dimensional (4D) PET/CT imaging of the thorax

    SciTech Connect

    Nehmeh, S.A.; Erdi, Y.E.; Pan, T.

    2004-12-01

    We have reported in our previous studies on the methodology, and feasibility of 4D-PET (Gated PET) acquisition, to reduce respiratory motion artifact in PET imaging of the thorax. In this study, we expand our investigation to address the problem of respiration motion in PET/CT imaging. The respiratory motion of four lung cancer patients were monitored by tracking external markers placed on the thorax. A 4D-CT acquisition was performed using a 'step-and-shoot' technique, in which computed tomography (CT) projection data were acquired over a complete respiratory cycle at each couch position. The period of each CT acquisition segment was time stamped with an 'x-ray ON' signal, which was recorded by the tracking system. 4D-CT data were then sorted into 10 groups, according to their corresponding phase of the breathing cycle. 4D-PET data were acquired in the gated mode, where each breathing cycle was divided into ten 0.5 s bins. For both CT and PET acquisitions, patients received audio prompting to regularize breathing. The 4D-CT and 4D-PET data were then correlated according to respiratory phase. The effect of 4D acquisition on improving the co-registration of PET and CT images, reducing motion smearing, and consequently increase the quantitation of the SUV, were investigated. Also, quantitation of the tumor motions in PET, and CT, were studied and compared. 4D-PET with matching phase 4D-CTAC showed an improved accuracy in PET-CT image co-registration of up to 41%, compared to measurements from 4D-PET with clinical-CTAC. Gating PET data in correlation with respiratory motion reduced motion-induced smearing, thereby decreasing the observed tumor volume, by as much as 43%. 4D-PET lesions volumes showed a maximum deviation of 19% between clinical CT and phase- matched 4D-CT attenuation corrected PET images. In CT, 4D acquisition resulted in increasing the tumor volume in two patients by up to 79%, and decreasing it in the other two by up to 35%. Consequently, these

  6. Actively triggered 4d cone-beam CT acquisition

    SciTech Connect

    Fast, Martin F.; Wisotzky, Eric; Oelfke, Uwe; Nill, Simeon

    2013-09-15

    Purpose: 4d cone-beam computed tomography (CBCT) scans are usually reconstructed by extracting the motion information from the 2d projections or an external surrogate signal, and binning the individual projections into multiple respiratory phases. In this “after-the-fact” binning approach, however, projections are unevenly distributed over respiratory phases resulting in inefficient utilization of imaging dose. To avoid excess dose in certain respiratory phases, and poor image quality due to a lack of projections in others, the authors have developed a novel 4d CBCT acquisition framework which actively triggers 2d projections based on the forward-predicted position of the tumor.Methods: The forward-prediction of the tumor position was independently established using either (i) an electromagnetic (EM) tracking system based on implanted EM-transponders which act as a surrogate for the tumor position, or (ii) an external motion sensor measuring the chest-wall displacement and correlating this external motion to the phase-shifted diaphragm motion derived from the acquired images. In order to avoid EM-induced artifacts in the imaging detector, the authors devised a simple but effective “Faraday” shielding cage. The authors demonstrated the feasibility of their acquisition strategy by scanning an anthropomorphic lung phantom moving on 1d or 2d sinusoidal trajectories.Results: With both tumor position devices, the authors were able to acquire 4d CBCTs free of motion blurring. For scans based on the EM tracking system, reconstruction artifacts stemming from the presence of the EM-array and the EM-transponders were greatly reduced using newly developed correction algorithms. By tuning the imaging frequency independently for each respiratory phase prior to acquisition, it was possible to harmonize the number of projections over respiratory phases. Depending on the breathing period (3.5 or 5 s) and the gantry rotation time (4 or 5 min), between ∼90 and 145

  7. The Use of Gated and 4D CT Imaging in Planning for Stereotactic Body Radiation Therapy

    SciTech Connect

    D'Souza, Warren D. . E-mail: wdsou001@umaryland.edu; Nazareth, Daryl P.; Zhang Bin; Deyoung, Chad; Suntharalingam, Mohan; Kwok, Young; Yu, Cedric X.; Regine, William F.

    2007-07-01

    The localization of treatment targets is of utmost importance for patients receiving stereotactic body radiation therapy (SBRT), where the dose per fraction is large. While both setup or respiration-induced motion components affect the localization of the treatment volume, the purpose of this work is to describe our management of the intrafraction localization uncertainty induced by normal respiration. At our institution, we have implemented gated computed tomography (CT) acquisition with an active breathing control system (ABC), and 4-dimensional (4D) CT using a skin-based marker and retrospective respiration phase-based image sorting. During gated simulation, 3D CT images were acquired corresponding to end-inhalation and end-exhalation. For 4D CT imaging, 3D CT images were acquired corresponding to 8 phases of the respiratory cycle. In addition to gated or 4D CT images, we acquired a conventional free-breathing CT (FB). For both gated and 4D CT images, the target contours were registered to the FB scan in the planning system. These contours were then combined in the FB image set to form the internal target volume (ITV). Dynamic conformal arc treatment plans were generated for the ITV using the FB scan and the gated or 4D scans with an additional 7-mm margin for patient setup uncertainty. We have described our results for a pancreas and a lung tumor case. Plans were normalized so that the PTV received 95% of the prescription dose. The dose distribution for all the critical structures in the pancreas and lung tumor cases resulted in increased sparing when the ITV was defined using gated or 4D CT images than when the FB scan was used. Our results show that patient-specific target definition using gated or 4D CT scans lead to improved normal tissue sparing.

  8. SU-E-J-187: Individually Optimized Contrast-Enhancement 4D-CT for Pancreatic Adenocarcinoma in Radiotherapy Simulation

    SciTech Connect

    Xue, M; Patel, K; Regine, W; Lane, B; D'Souza, W; Lu, W; Klahr, P

    2014-06-01

    Purpose: To study the feasibility of individually optimized contrastenhancement (CE) 4D-CT for pancreatic adenocarcinoma (PDA) in radiotherapy simulation. To evaluate the image quality and contrast enhancement of tumor in the CE 4D-CT, compared to the clinical standard of CE 3D-CT and 4D-CT. Methods: In this IRB-approved study, each of the 7 PDA patients enrolled underwent 3 CT scans: a free-breathing 3D-CT with contrast (CE 3D-CT) followed by a 4D-CT without contrast (4D-CT) in the first study session, and a 4D-CT with individually synchronized contrast injection (CE 4D-CT) in the second study session. In CE 4D-CT, the time of full contrast injection was determined based on the time of peak enhancement for the test injection, injection rate, table speed, and longitudinal location and span of the pancreatic region. Physicians contoured both the tumor (T) and the normal pancreatic parenchyma (P) on the three CTs (end-of-exhalation for 4D-CT). The contrast between the tumor and normal pancreatic tissue was computed as the difference of the mean enhancement level of three 1 cm3 regions of interests in T and P, respectively. Wilcoxon rank sum test was used to statistically compare the scores and contrasts. Results: In qualitative evaluations, both CE 3D-CT and CE 4D-CT scored significantly better than 4D-CT (4.0 and 3.6 vs. 2.6). There was no significant difference between CE 3D-CT and CE 4D-CT. In quantitative evaluations, the contrasts between the tumor and the normal pancreatic parenchyma were 0.6±23.4, −2.1±8.0, and −19.6±28.8 HU, in CE 3D-CT, 4D-CT, and CE 4D-CT, respectively. Although not statistically significant, CE 4D-CT achieved better contrast enhancement between the tumor and the normal pancreatic parenchyma than both CE 3D-CT and 4DCT. Conclusion: CE 4D-CT achieved equivalent image quality and better contrast enhancement between tumor and normal pancreatic parenchyma than the clinical standard of CE 3D-CT and 4D-CT. This study was supported in part

  9. TH-E-BRF-02: 4D-CT Ventilation Image-Based IMRT Plans Are Dosimetrically Comparable to SPECT Ventilation Image-Based Plans

    SciTech Connect

    Kida, S; Bal, M; Kabus, S; Loo, B; Keall, P; Yamamoto, T

    2014-06-15

    Purpose: An emerging lung ventilation imaging method based on 4D-CT can be used in radiotherapy to selectively avoid irradiating highly-functional lung regions, which may reduce pulmonary toxicity. Efforts to validate 4DCT ventilation imaging have been focused on comparison with other imaging modalities including SPECT and xenon CT. The purpose of this study was to compare 4D-CT ventilation image-based functional IMRT plans with SPECT ventilation image-based plans as reference. Methods: 4D-CT and SPECT ventilation scans were acquired for five thoracic cancer patients in an IRB-approved prospective clinical trial. The ventilation images were created by quantitative analysis of regional volume changes (a surrogate for ventilation) using deformable image registration of the 4D-CT images. A pair of 4D-CT ventilation and SPECT ventilation image-based IMRT plans was created for each patient. Regional ventilation information was incorporated into lung dose-volume objectives for IMRT optimization by assigning different weights on a voxel-by-voxel basis. The objectives and constraints of the other structures in the plan were kept identical. The differences in the dose-volume metrics have been evaluated and tested by a paired t-test. SPECT ventilation was used to calculate the lung functional dose-volume metrics (i.e., mean dose, V20 and effective dose) for both 4D-CT ventilation image-based and SPECT ventilation image-based plans. Results: Overall there were no statistically significant differences in any dose-volume metrics between the 4D-CT and SPECT ventilation imagebased plans. For example, the average functional mean lung dose of the 4D-CT plans was 26.1±9.15 (Gy), which was comparable to 25.2±8.60 (Gy) of the SPECT plans (p = 0.89). For other critical organs and PTV, nonsignificant differences were found as well. Conclusion: This study has demonstrated that 4D-CT ventilation image-based functional IMRT plans are dosimetrically comparable to SPECT ventilation image

  10. 4D CT amplitude binning for the generation of a time-averaged 3D mid-position CT scan.

    PubMed

    Kruis, Matthijs F; van de Kamer, Jeroen B; Belderbos, José S A; Sonke, Jan-Jakob; van Herk, Marcel

    2014-09-21

    The purpose of this study was to develop a method to use amplitude binned 4D-CT (A-4D-CT) data for the construction of mid-position CT data and to compare the results with data created from phase-binned 4D-CT (P-4D-CT) data. For the latter purpose we have developed two measures which describe the regularity of the 4D data and we have tried to correlate these measures with the regularity of the external respiration signal. 4D-CT data was acquired for 27 patients on a combined PET-CT scanner. The 4D data were reconstructed twice, using phase and amplitude binning. The 4D frames of each dataset were registered using a quadrature-based optical flow method. After registration the deformation vector field was repositioned to the mid-position. Since amplitude-binned 4D data does not provide temporal information, we corrected the mid-position for the occupancy of the bins. We quantified the differences between the two mid-position datasets in terms of tumour offset and amplitude differences. Furthermore, we measured the standard deviation of the image intensity over the respiration after registration (σregistration) and the regularity of the deformation vector field (Delta J) to quantify the quality of the 4D-CT data. These measures were correlated to the regularity of the external respiration signal (σsignal).The two irregularity measures, Delta J and σregistration, were dependent on each other (p<0.0001, R2=0.80 for P-4D-CT, R2=0.74 for A-4D-CT). For all datasets amplitude binning resulted in lower Delta J and σregistration and large decreases led to visible quality improvements in the mid-position data. The quantity of artefact decrease was correlated to the irregularity of the external respiratory signal.The average tumour offset between the phase and amplitude binned mid-position without occupancy correction was 0.42 mm in the caudal direction (10.6% of the amplitude). After correction this was reduced to 0.16 mm in caudal direction (4.1% of the amplitude

  11. Resolution enhancement of lung 4D-CT data using multiscale interphase iterative nonlocal means

    SciTech Connect

    Zhang Yu; Yap, Pew-Thian; Wu Guorong; Feng Qianjin; Chen Wufan; Lian Jun; Shen Dinggang

    2013-05-15

    Purpose: Four-dimensional computer tomography (4D-CT) has been widely used in lung cancer radiotherapy due to its capability in providing important tumor motion information. However, the prolonged scanning duration required by 4D-CT causes considerable increase in radiation dose. To minimize the radiation-related health risk, radiation dose is often reduced at the expense of interslice spatial resolution. However, inadequate resolution in 4D-CT causes artifacts and increases uncertainty in tumor localization, which eventually results in extra damages of healthy tissues during radiotherapy. In this paper, the authors propose a novel postprocessing algorithm to enhance the resolution of lung 4D-CT data. Methods: The authors' premise is that anatomical information missing in one phase can be recovered from the complementary information embedded in other phases. The authors employ a patch-based mechanism to propagate information across phases for the reconstruction of intermediate slices in the longitudinal direction, where resolution is normally the lowest. Specifically, the structurally matching and spatially nearby patches are combined for reconstruction of each patch. For greater sensitivity to anatomical details, the authors employ a quad-tree technique to adaptively partition the image for more fine-grained refinement. The authors further devise an iterative strategy for significant enhancement of anatomical details. Results: The authors evaluated their algorithm using a publicly available lung data that consist of 10 4D-CT cases. The authors' algorithm gives very promising results with significantly enhanced image structures and much less artifacts. Quantitative analysis shows that the authors' algorithm increases peak signal-to-noise ratio by 3-4 dB and the structural similarity index by 3%-5% when compared with the standard interpolation-based algorithms. Conclusions: The authors have developed a new algorithm to improve the resolution of 4D-CT. It outperforms

  12. Computer-aided diagnosis in thoracic CT

    NASA Astrophysics Data System (ADS)

    Li, Qiang

    2009-10-01

    Computer-aided diagnosis (CAD) provides a computer output as a "second opinion" in order to assist radiologists in the diagnosis of various diseases on medical images. Currently, a hot topic in CAD is the development of computerized schemes for detection of lung abnormalities, such as lung nodule and interstitial lung disease, in computed tomography (CT) images. The author describes in this article the current status of the CAD schemes for the detection of lung nodules and interstitial lung disease in CT developed by the author and his colleagues at the University of Chicago and Duke University.

  13. SU-E-J-148: Tools for Development of 4D Proton CT

    SciTech Connect

    Dou, T; Ramos-Mendez, J; Piersimoni, P; Giacometti, V; Penfold, S; Censor, Y; Faddegon, B; Low, D; Schulte, R

    2015-06-15

    Purpose: To develop tools for performing 4D proton computed tomography (CT). Methods: A suitable patient with a tumor in the right lower lobe was selected from a set of 4D CT scans. The volumetric CT images formed the basis for calculating the parameters of a breathing model that allows reconstruction of a static reference CT and CT images in each breathing phase. The images were imported into the TOPAS Monte Carlo simulation platform for simulating an experimental proton CT scan with 45 projections spaced by 4 degree intervals. Each projection acquired data for 2 seconds followed by a gantry rotation for 2 seconds without acquisition. The scan covered 180 degrees with individual protons passing through a 9-cm slab of the patient’s lung covering the moving tumor. An initial proton energy sufficient for penetrating the patient from all directions was determined. Performing the proton CT simulation, TOPAS provided output of the proton energy and coordinates registered in two planes before and after the patient, respectively. The set of projection data was then used with an iterative reconstruction algorithm to generate a volumetric proton CT image set of the static reference image and the image obtained under breathing motion, respectively. Results: An initial proton energy of 230 MeV was found to be sufficient, while for an initial energy of 200 MeV a substantial number of protons did not penetrate the patient. The reconstruction of the static reference image set provided sufficient detail for treatment planning. Conclusion: We have developed tools to perform studies of proton CT in the presence of lung motion based on the TOPAS simulation toolkit. This will allow to optimize 4D reconstruction algorithms by synchronizing the acquired proton CT data with a breathing signal and utilizing a breathing model obtained prior to the proton CT scan. This research has been supported by the National Institute Of Biomedical Imaging And Bioengineering of the National

  14. A phantom for testing of 4D-CT for radiotherapy of small lesions

    SciTech Connect

    Dunn, L.; Kron, T.; Taylor, M. L.; Callahan, J.; Franich, R. D.

    2012-09-15

    Purpose: The use of time-resolved four-dimensional computed tomography (4D-CT) in radiotherapy requires strict quality assurance to ensure the accuracy of motion management protocols. The aim of this work was to design and test a phantom capable of large amplitude motion for use in 4D-CT, with particular interest in small lesions typical for stereotactic body radiotherapy. Methods: The phantom of 'see-saw' design is light weight, capable of including various sample materials and compatible with several surrogate marker signal acquisition systems. It is constructed of polymethylmethacrylate (Perspex) and its movement is controlled via a dc motor and drive wheel. It was tested using two CT scanners with different 4D acquisition methods: the Philips Brilliance Big Bore CT (helical scan, pressure belt) and a General Electric Discovery STE PET/CT (axial scan, infrared marker). Amplitudes ranging from 1.5 to 6.0 cm and frequencies of up to 40 cycles per minute were used to study the effect of motion on image quality. Maximum intensity projections (MIPs), as well as average intensity projections (AIPs) of moving objects were investigated and their quality dependence on the number of phase reconstruction bins assessed. Results: CT number discrepancies between moving and stationary objects were found to have no systematic dependence on amplitude, frequency, or specific interphase variability. MIP-delineated amplitudes of motion were found to match physical phantom amplitudes to within 2 mm for all motion scenarios tested. Objects undergoing large amplitude motions (>3.0 cm) were shown to cause artefacts in MIP and AIP projections when ten phase bins were assigned. This problem can be mitigated by increasing the number of phase bins in a 4D-CT scan. Conclusions: The phantom was found to be a suitable tool for evaluating the image quality of 4D-CT motion management technology, as well as providing a quality assurance tool for intercenter/intervendor testing of commercial 4D-CT

  15. Resolution enhancement of lung 4D-CT via group-sparsity

    SciTech Connect

    Bhavsar, Arnav; Wu, Guorong; Shen, Dinggang; Lian, Jun

    2013-12-15

    Purpose: 4D-CT typically delivers more accurate information about anatomical structures in the lung, over 3D-CT, due to its ability to capture visual information of the lung motion across different respiratory phases. This helps to better determine the dose during radiation therapy for lung cancer. However, a critical concern with 4D-CT that substantially compromises this advantage is the low superior-inferior resolution due to less number of acquired slices, in order to control the CT radiation dose. To address this limitation, the authors propose an approach to reconstruct missing intermediate slices, so as to improve the superior-inferior resolution.Methods: In this method the authors exploit the observation that sampling information across respiratory phases in 4D-CT can be complimentary due to lung motion. The authors’ approach uses this locally complimentary information across phases in a patch-based sparse-representation framework. Moreover, unlike some recent approaches that treat local patches independently, the authors’ approach employs the group-sparsity framework that imposes neighborhood and similarity constraints between patches. This helps in mitigating the trade-off between noise robustness and structure preservation, which is an important consideration in resolution enhancement. The authors discuss the regularizing ability of group-sparsity, which helps in reducing the effect of noise and enables better structural localization and enhancement.Results: The authors perform extensive experiments on the publicly available DIR-Lab Lung 4D-CT dataset [R. Castillo, E. Castillo, R. Guerra, V. Johnson, T. McPhail, A. Garg, and T. Guerrero, “A framework for evaluation of deformable image registration spatial accuracy using large landmark point sets,” Phys. Med. Biol. 54, 1849–1870 (2009)]. First, the authors carry out empirical parametric analysis of some important parameters in their approach. The authors then demonstrate, qualitatively as well as

  16. Retrospective Analysis of Artifacts in Four-Dimensional CT Images of 50 Abdominal and Thoracic Radiotherapy Patients

    SciTech Connect

    Yamamoto, Tokihiro Langner, Ulrich; Loo, Billy W.; Shen, John; Keall, Paul J.

    2008-11-15

    Purpose: To quantify the type, frequency, and magnitude of artifacts in four-dimensional (4D) CT images acquired using a multislice cine method. Methods and Materials: Fifty consecutive patients who underwent 4D-CT scanning and radiotherapy for thoracic or abdominal cancers were included in this study. All the 4D-CT scans were performed on the GE multislice PET/CT scanner with the Varian Real-time Position Management system in cine mode. The GE Advantage 4D software was used to create 4D-CT data sets. The artifacts were then visually and quantitatively analyzed. We performed statistical analyses to evaluate the relationships between patient- or breathing-pattern-related parameters and the occurrence as well as magnitude of artifacts. Results: It was found that 45 of 50 patients (90%) had at least one artifact (other than blurring) with a mean magnitude of 11.6 mm (range, 4.4-56.0 mm) in the diaphragm or heart. We also observed at least one artifact in 6 of 20 lung or mediastinal tumors (30%). Statistical analysis revealed that there were significant differences between several breathing-pattern-related parameters, including abdominal displacement (p < 0.01), for the subgroups of patients with and without artifacts. The magnitude of an artifact was found to be significantly but weakly correlated with the abdominal displacement difference between two adjacent couch positions (R = 0.34, p < 0.01). Conclusions: This study has identified that the frequency and magnitude of artifacts in 4D-CT is alarmingly high. Significant improvement is needed in 4D-CT imaging.

  17. Geometric validation of self-gating k-space-sorted 4D-MRI vs 4D-CT using a respiratory motion phantom

    SciTech Connect

    Yue, Yong Yang, Wensha; McKenzie, Elizabeth; Tuli, Richard; Wallace, Robert; Fraass, Benedick; Fan, Zhaoyang; Pang, Jianing; Deng, Zixin; Li, Debiao

    2015-10-15

    Purpose: MRI is increasingly being used for radiotherapy planning, simulation, and in-treatment-room motion monitoring. To provide more detailed temporal and spatial MR data for these tasks, we have recently developed a novel self-gated (SG) MRI technique with advantage of k-space phase sorting, high isotropic spatial resolution, and high temporal resolution. The current work describes the validation of this 4D-MRI technique using a MRI- and CT-compatible respiratory motion phantom and comparison to 4D-CT. Methods: The 4D-MRI sequence is based on a spoiled gradient echo-based 3D projection reconstruction sequence with self-gating for 4D-MRI at 3 T. Respiratory phase is resolved by using SG k-space lines as the motion surrogate. 4D-MRI images are reconstructed into ten temporal bins with spatial resolution 1.56 × 1.56 × 1.56 mm{sup 3}. A MRI-CT compatible phantom was designed to validate the performance of the 4D-MRI sequence and 4D-CT imaging. A spherical target (diameter 23 mm, volume 6.37 ml) filled with high-concentration gadolinium (Gd) gel is embedded into a plastic box (35 × 40 × 63 mm{sup 3}) and stabilized with low-concentration Gd gel. The phantom, driven by an air pump, is able to produce human-type breathing patterns between 4 and 30 respiratory cycles/min. 4D-CT of the phantom has been acquired in cine mode, and reconstructed into ten phases with slice thickness 1.25 mm. The 4D images sets were imported into a treatment planning software for target contouring. The geometrical accuracy of the 4D MRI and CT images has been quantified using target volume, flattening, and eccentricity. The target motion was measured by tracking the centroids of the spheres in each individual phase. Motion ground-truth was obtained from input signals and real-time video recordings. Results: The dynamic phantom has been operated in four respiratory rate (RR) settings, 6, 10, 15, and 20/min, and was scanned with 4D-MRI and 4D-CT. 4D-CT images have target

  18. Palmar hyperhidrosis CT guided chemical percutaneous thoracic sympathectomy.

    PubMed

    Adler, O B; Engel, A; Rosenberger, A; Dondelinger, R

    1990-10-01

    Palmar hyperhidrosis or excessive sweating of the hands causes, to those affected, emotional and physical disturbance and impediment in professional and social life. The cause is unknown. Sweat glands are innervated by the sympathetic chain of the autonomous nervous system. The center of sympathetic regulation of the upper extremities is located between the segments of D.2-D.9 of the spinal cord. Accepted treatment consists of surgery aimed to excise the third thoracic sympathetic ganglion. Besides the surgical procedure as such, and its complications, there are complications inherent to the excision of the ganglion. These are Horner's syndrome, compensatory sweating in other parts of the body, and recurrence of sweating. CT guided chemical percutaneous thoracic sympathectomy presents an alternative, which in the event of failure does not prevent ensuing surgery. The preliminary experience with this procedure in 50 patients is presented and discussed.

  19. Comparison of 4D-microSPECT and microCT for murine cardiac function

    PubMed Central

    Befera, Nicholas T.; Badea, Cristian T.; Johnson, G. Allan

    2014-01-01

    Purpose The objective of this study was to compare a new generation of four-dimensional (4D) microSPECT with microCT for quantitative in vivo assessment of murine cardiac function. Procedures 4D isotropic cardiac images were acquired from normal C57BL/6 mice with either microSPECT at 350-micron resolution (n=6) or microCT at 88-micron resolution (n=6). One additional mouse with myocardial infarction (MI) was scanned with both modalities. Prior to imaging, mice were injected with either 99mTc -tetrofosmin for microSPECT, or a liposomal blood pool contrast agent for microCT. Segmentation of the left ventricle (LV) was performed using Vitrea (Vital Images) software, to derive global and regional function. Results Measures of global LV function between microSPECT and microCT groups were comparable (e.g. ejection fraction=71±6%-microSPECT and 68±4%-microCT). Regional functional indices (wall motion, wall thickening, regional ejection fraction) were also similar for the two modalities. In the mouse with MI, microSPECT identified a large perfusion defect that was not evident with microCT. Conclusions Despite lower spatial resolution, microSPECT was comparable to microCT in the quantitative evaluation of cardiac function. MicroSPECT offers an advantage over microCT in the ability to evaluate myocardial perfusion radiotracer distribution and function simultaneously. MicroSPECT should be considered as an alternative to microCT and MR for preclinical cardiac imaging in the mouse. PMID:24037175

  20. Simultaneous motion estimation and image reconstruction (SMEIR) for 4D cone-beam CT

    NASA Astrophysics Data System (ADS)

    Wang, Jing; Gu, Xuejun

    2014-03-01

    Image reconstruction and motion model estimation in four dimensional cone-beam CT (4D-CBCT) are conventionally handled as two sequential steps. Due to the limited number of projections at each phase, the image quality of 4D-CBCT is degraded by view aliasing artifacts, and the accuracy of subsequent motion modeling is decreased by the inferior 4DCBCT. The objective of this work is to enhance both the image quality of 4D-CBCT and the accuracy of motion model estimation with a novel strategy enabling simultaneous motion estimation and image reconstruction (SMEIR). The proposed SMEIR algorithm consists of two alternating steps: 1) model-based iterative image reconstruction to obtain a motion-compensated primary CBCT (m-pCBCT) and 2) motion model estimation to obtain an optimal set of deformation vector fields (DVFs) between the m-pCBCT and other 4D-CBCT phases. The motion-compensated image reconstruction is based on the simultaneous algebraic reconstruction (SART) technique coupled with total variation minimization. During the forward- and back-projection of SART, measured projections from an entire set of 4D-CBCT are used for reconstruction of the m-pCBCT by utilizing the updated DVF. The DVF is estimated by matching the forward projection of the deformed m-pCBCT and measured projections of other phases of 4D-CBCT. The performance of the SMEIR algorithm is quantitatively evaluated on a 4D NCAT phantom. The SMEIR algorithm improves image reconstruction accuracy of 4D-CBCT and tumor motion trajectory estimation accuracy as compared to conventional sequential 4D-CBCT reconstruction and motion estimation.

  1. A hybrid reconstruction algorithm for fast and accurate 4D cone-beam CT imaging

    SciTech Connect

    Yan, Hao; Folkerts, Michael; Jiang, Steve B. E-mail: steve.jiang@UTSouthwestern.edu; Jia, Xun E-mail: steve.jiang@UTSouthwestern.edu; Zhen, Xin; Li, Yongbao; Pan, Tinsu; Cervino, Laura

    2014-07-15

    Purpose: 4D cone beam CT (4D-CBCT) has been utilized in radiation therapy to provide 4D image guidance in lung and upper abdomen area. However, clinical application of 4D-CBCT is currently limited due to the long scan time and low image quality. The purpose of this paper is to develop a new 4D-CBCT reconstruction method that restores volumetric images based on the 1-min scan data acquired with a standard 3D-CBCT protocol. Methods: The model optimizes a deformation vector field that deforms a patient-specific planning CT (p-CT), so that the calculated 4D-CBCT projections match measurements. A forward-backward splitting (FBS) method is invented to solve the optimization problem. It splits the original problem into two well-studied subproblems, i.e., image reconstruction and deformable image registration. By iteratively solving the two subproblems, FBS gradually yields correct deformation information, while maintaining high image quality. The whole workflow is implemented on a graphic-processing-unit to improve efficiency. Comprehensive evaluations have been conducted on a moving phantom and three real patient cases regarding the accuracy and quality of the reconstructed images, as well as the algorithm robustness and efficiency. Results: The proposed algorithm reconstructs 4D-CBCT images from highly under-sampled projection data acquired with 1-min scans. Regarding the anatomical structure location accuracy, 0.204 mm average differences and 0.484 mm maximum difference are found for the phantom case, and the maximum differences of 0.3–0.5 mm for patients 1–3 are observed. As for the image quality, intensity errors below 5 and 20 HU compared to the planning CT are achieved for the phantom and the patient cases, respectively. Signal-noise-ratio values are improved by 12.74 and 5.12 times compared to results from FDK algorithm using the 1-min data and 4-min data, respectively. The computation time of the algorithm on a NVIDIA GTX590 card is 1–1.5 min per phase

  2. Simultaneous motion estimation and image reconstruction (SMEIR) for 4D cone-beam CT

    SciTech Connect

    Wang, Jing; Gu, Xuejun

    2013-10-15

    Purpose: Image reconstruction and motion model estimation in four-dimensional cone-beam CT (4D-CBCT) are conventionally handled as two sequential steps. Due to the limited number of projections at each phase, the image quality of 4D-CBCT is degraded by view aliasing artifacts, and the accuracy of subsequent motion modeling is decreased by the inferior 4D-CBCT. The objective of this work is to enhance both the image quality of 4D-CBCT and the accuracy of motion model estimation with a novel strategy enabling simultaneous motion estimation and image reconstruction (SMEIR).Methods: The proposed SMEIR algorithm consists of two alternating steps: (1) model-based iterative image reconstruction to obtain a motion-compensated primary CBCT (m-pCBCT) and (2) motion model estimation to obtain an optimal set of deformation vector fields (DVFs) between the m-pCBCT and other 4D-CBCT phases. The motion-compensated image reconstruction is based on the simultaneous algebraic reconstruction technique (SART) coupled with total variation minimization. During the forward- and backprojection of SART, measured projections from an entire set of 4D-CBCT are used for reconstruction of the m-pCBCT by utilizing the updated DVF. The DVF is estimated by matching the forward projection of the deformed m-pCBCT and measured projections of other phases of 4D-CBCT. The performance of the SMEIR algorithm is quantitatively evaluated on a 4D NCAT phantom. The quality of reconstructed 4D images and the accuracy of tumor motion trajectory are assessed by comparing with those resulting from conventional sequential 4D-CBCT reconstructions (FDK and total variation minimization) and motion estimation (demons algorithm). The performance of the SMEIR algorithm is further evaluated by reconstructing a lung cancer patient 4D-CBCT.Results: Image quality of 4D-CBCT is greatly improved by the SMEIR algorithm in both phantom and patient studies. When all projections are used to reconstruct a 3D-CBCT by FDK, motion

  3. Thoracic cancer imaging with PET/CT in radiation oncology

    NASA Astrophysics Data System (ADS)

    Chi, Pai-Chun Melinda

    Significance. Respiratory motion has been shown to cause artifacts in PET/CT imaging. This breathing artifact can have a significant impact on PET quantification and it can lead to large uncertainties when using PET for radiation therapy planning. We have demonstrated a promising solution to resolve the breathing artifact by acquiring respiration-averaged CT (ACT) for PET/CT. The purpose of this work was to optimize the ACT acquisition for clinical implementation and to evaluate the impact of ACT on PET/CT quantification. The hypothesis was that ACT is an effective method in removing the breathing artifact when compared to our current clinical protocol. Methods. Phase and cine approaches for acquiring ACT were investigated and the results of these two approaches were compared to the ACT generated from clinical 4DCT data sets (abbreviated as ACT10phs ). In the phase approach, ACT was generated based on combinations of selected respiratory phases; in the cine approach, ACT was generated based on cine images acquired over a fixed cine duration. The phase combination and cine duration that best approximated the ACT10phs were determined to be the optimized scanning parameters. 216 thoracic PET/CT patients were scanned with both current clinical and the ACT protocols. The effects of ACT on PET/CT quantification were assessed by comparing clinical PET/CT and ACT PET/CT using 3 metrics: PET/CT image alignment, maximum standardized uptake value (SUVmax), and threshold segmented gross tumor volume (GTV). Results. ACT10phs can be best approximated to within 2% of SUV variation by phase averaging based on 4 representative phases, and to within 3% by cine image averaging based on >3s of cine duration. We implemented the cine approach on the PET/CT scanners and acquired 216 patient data sets. 68% of patients had breathing artifacts in their clinical PET/CT and the artifacts were removed/reduced in all corresponding ACT PET/CT. PET/CT quantification for lesions <50 cm3 and

  4. SU-E-J-120: Comparing 4D CT Computed Ventilation to Lung Function Measured with Hyperpolarized Xenon-129 MRI

    SciTech Connect

    Neal, B; Chen, Q

    2015-06-15

    Purpose: To correlate ventilation parameters computed from 4D CT to ventilation, profusion, and gas exchange measured with hyperpolarized Xenon-129 MRI for a set of lung cancer patients. Methods: Hyperpolarized Xe-129 MRI lung scans were acquired for lung cancer patients, before and after radiation therapy, measuring ventilation, perfusion, and gas exchange. In the standard clinical workflow, these patients also received 4D CT scans before treatment. Ventilation was computed from 4D CT using deformable image registration (DIR). All phases of the 4D CT scan were registered using a B-spline deformable registration. Ventilation at the voxel level was then computed for each phase based on a Jacobian volume expansion metric, yielding phase sorted ventilation images. Ventilation based upon 4D CT and Xe-129 MRI were co-registered, allowing qualitative visual comparison and qualitative comparison via the Pearson correlation coefficient. Results: Analysis shows a weak correlation between hyperpolarized Xe-129 MRI and 4D CT DIR ventilation, with a Pearson correlation coefficient of 0.17 to 0.22. Further work will refine the DIR parameters to optimize the correlation. The weak correlation could be due to the limitations of 4D CT, registration algorithms, or the Xe-129 MRI imaging. Continued development will refine parameters to optimize correlation. Conclusion: Current analysis yields a minimal correlation between 4D CT DIR and Xe-129 MRI ventilation. Funding provided by the 2014 George Amorino Pilot Grant in Radiation Oncology at the University of Virginia.

  5. Clinical Utility of 4D FDG-PET/CT Scans in Radiation Treatment Planning

    SciTech Connect

    Aristophanous, Michalis; Sher, David J.; Allen, Aaron M.; Larson, Elysia; Chen, Aileen B.

    2012-01-01

    Purpose: The potential role of four-dimensional (4D) positron emission tomography (PET)/computed tomography (CT) in radiation treatment planning, relative to standard three-dimensional (3D) PET/CT, was examined. Methods and Materials: Ten patients with non-small-cell lung cancer had sequential 3D and 4D [{sup 18}F]fluorodeoxyglucose PET/CT scans in the treatment position prior to radiation therapy. The gross tumor volume and involved lymph nodes were contoured on the PET scan by use of three different techniques: manual contouring by an experienced radiation oncologist using a predetermined protocol; a technique with a constant threshold of standardized uptake value (SUV) greater than 2.5; and an automatic segmentation technique. For each technique, the tumor volume was defined on the 3D scan (VOL3D) and on the 4D scan (VOL4D) by combining the volume defined on each of the five breathing phases individually. The range of tumor motion and the location of each lesion were also recorded, and their influence on the differences observed between VOL3D and VOL4D was investigated. Results: We identified and analyzed 22 distinct lesions, including 9 primary tumors and 13 mediastinal lymph nodes. Mean VOL4D was larger than mean VOL3D with all three techniques, and the difference was statistically significant (p < 0.01). The range of tumor motion and the location of the tumor affected the magnitude of the difference. For one case, all three tumor definition techniques identified volume of moderate uptake of approximately 1 mL in the hilar region on the 4D scan (SUV maximum, 3.3) but not on the 3D scan (SUV maximum, 2.3). Conclusions: In comparison to 3D PET, 4D PET may better define the full physiologic extent of moving tumors and improve radiation treatment planning for lung tumors. In addition, reduction of blurring from free-breathing images may reveal additional information regarding regional disease.

  6. Noise filtering in thin-slice 4D cerebral CT perfusion scans

    NASA Astrophysics Data System (ADS)

    Mendrik, Adri"nne; Vonken, Evert-jan; Dankbaar, Jan-Willem; Prokop, Mathias; van Ginneken, Bram

    2010-03-01

    Patients suffering from cerebral ischemia or subarachnoid hemorrhage, undergo a 4D (3D+time) CT Perfusion (CTP) scan to assess the cerebral perfusion and a CT Angiography (CTA) scan to assess the vasculature. The aim of our research is to extract the vascular information from the CTP scan. This requires thin-slice CTP scans that suffer from a substantial amount of noise. Therefore noise reduction is an important prerequisite for further analysis. So far, the few noise filtering methods for 4D datasets proposed in literature deal with the temporal dimension as a 4th dimension similar to the 3 spatial dimensions, mixing temporal and spatial intensity information. We propose a bilateral noise reduction method based on time-intensity profile similarity (TIPS), which reduces noise while preserving temporal intensity information. TIPS was compared to 4D bilateral filtering on 10 patient CTP scans and, even though TIPS bilateral filtering is much faster, it results in better vessel visibility and higher image quality ranking (observer study) than 4D bilateral filtering.

  7. Registration based super-resolution reconstruction for lung 4D-CT.

    PubMed

    Wu, Xiuxiu; Xiao, Shan; Zhang, Yu

    2014-01-01

    Lung 4D-CT plays an important role in lung cancer radiotherapy for tumor localization and treatment planning. In lung 4D-CT data, the resolution in the slice direction is often much lower than the in-plane resolution. For multi-plane display, isotropic resolution is necessary, but the commonly used interpolation operation will blur the images. In this paper, we present a registration based method for super resolution enhancement of the 4D-CT multi-plane images. Our working premise is that the low-resolution images of different phases at the corresponding position can be regarded as input "frames" to reconstruct high resolution images. First, we employ the Demons registration algorithm to estimate the motion field between different "frames". Then, the projections onto convex sets (POCS) approach is employed to reconstruction high-resolution lung images. We show that our method can get clearer lung images and enhance image structure, compared with the cubic spline interpolation and back projection method. PMID:25570484

  8. Registration based super-resolution reconstruction for lung 4D-CT.

    PubMed

    Wu, Xiuxiu; Xiao, Shan; Zhang, Yu

    2014-01-01

    Lung 4D-CT plays an important role in lung cancer radiotherapy for tumor localization and treatment planning. In lung 4D-CT data, the resolution in the slice direction is often much lower than the in-plane resolution. For multi-plane display, isotropic resolution is necessary, but the commonly used interpolation operation will blur the images. In this paper, we present a registration based method for super resolution enhancement of the 4D-CT multi-plane images. Our working premise is that the low-resolution images of different phases at the corresponding position can be regarded as input "frames" to reconstruct high resolution images. First, we employ the Demons registration algorithm to estimate the motion field between different "frames". Then, the projections onto convex sets (POCS) approach is employed to reconstruction high-resolution lung images. We show that our method can get clearer lung images and enhance image structure, compared with the cubic spline interpolation and back projection method.

  9. 4D cone-beam CT reconstruction using multi-organ meshes for sliding motion modeling.

    PubMed

    Zhong, Zichun; Gu, Xuejun; Mao, Weihua; Wang, Jing

    2016-02-01

    A simultaneous motion estimation and image reconstruction (SMEIR) strategy was proposed for 4D cone-beam CT (4D-CBCT) reconstruction and showed excellent results in both phantom and lung cancer patient studies. In the original SMEIR algorithm, the deformation vector field (DVF) was defined on voxel grid and estimated by enforcing a global smoothness regularization term on the motion fields. The objective of this work is to improve the computation efficiency and motion estimation accuracy of SMEIR for 4D-CBCT through developing a multi-organ meshing model. Feature-based adaptive meshes were generated to reduce the number of unknowns in the DVF estimation and accurately capture the organ shapes and motion. Additionally, the discontinuity in the motion fields between different organs during respiration was explicitly considered in the multi-organ mesh model. This will help with the accurate visualization and motion estimation of the tumor on the organ boundaries in 4D-CBCT. To further improve the computational efficiency, a GPU-based parallel implementation was designed. The performance of the proposed algorithm was evaluated on a synthetic sliding motion phantom, a 4D NCAT phantom, and four lung cancer patients. The proposed multi-organ mesh based strategy outperformed the conventional Feldkamp-Davis-Kress, iterative total variation minimization, original SMEIR and single meshing method based on both qualitative and quantitative evaluations.

  10. 4D cone-beam CT reconstruction using multi-organ meshes for sliding motion modeling

    NASA Astrophysics Data System (ADS)

    Zhong, Zichun; Gu, Xuejun; Mao, Weihua; Wang, Jing

    2016-02-01

    A simultaneous motion estimation and image reconstruction (SMEIR) strategy was proposed for 4D cone-beam CT (4D-CBCT) reconstruction and showed excellent results in both phantom and lung cancer patient studies. In the original SMEIR algorithm, the deformation vector field (DVF) was defined on voxel grid and estimated by enforcing a global smoothness regularization term on the motion fields. The objective of this work is to improve the computation efficiency and motion estimation accuracy of SMEIR for 4D-CBCT through developing a multi-organ meshing model. Feature-based adaptive meshes were generated to reduce the number of unknowns in the DVF estimation and accurately capture the organ shapes and motion. Additionally, the discontinuity in the motion fields between different organs during respiration was explicitly considered in the multi-organ mesh model. This will help with the accurate visualization and motion estimation of the tumor on the organ boundaries in 4D-CBCT. To further improve the computational efficiency, a GPU-based parallel implementation was designed. The performance of the proposed algorithm was evaluated on a synthetic sliding motion phantom, a 4D NCAT phantom, and four lung cancer patients. The proposed multi-organ mesh based strategy outperformed the conventional Feldkamp-Davis-Kress, iterative total variation minimization, original SMEIR and single meshing method based on both qualitative and quantitative evaluations.

  11. Interactive annotation of textures in thoracic CT scans

    NASA Astrophysics Data System (ADS)

    Kockelkorn, Thessa T. J. P.; de Jong, Pim A.; Gietema, Hester A.; Grutters, Jan C.; Prokop, Mathias; van Ginneken, Bram

    2010-03-01

    This study describes a system for interactive annotation of thoracic CT scans. Lung volumes in these scans are segmented and subdivided into roughly spherical volumes of interest (VOIs) with homogeneous texture using a clustering procedure. For each 3D VOI, 72 features are calculated. The observer inspects the scan to determine which textures are present and annotates, with mouse clicks, several VOIs of each texture. Based on these annotations, a k-nearest-neighbor classifier is trained, which classifies all remaining VOIs in the scan. The algorithm then presents a slice with suggested annotations to the user, in which the user can correct mistakes. The classifier is retrained, taking into account these new annotations, and the user is presented another slice for correction. This process continues until at least 50% of all lung voxels in the scan have been classified. The remaining VOIs are classified automatically. In this way, the entire lung volume is annotated. The system has been applied to scans of patients with usual and non-specific interstitial pneumonia. The results of interactive annotation are compared to a setup in which the user annotates all predefined VOIs manually. The interactive system is 3.7 times as fast as complete manual annotation of VOIs and differences between the methods are similar to interobserver variability. This is a first step towards precise volumetric quantitation of texture patterns in thoracic CT in clinical research and in clinical practice.

  12. 4D micro-CT for cardiac and perfusion applications with view under sampling

    NASA Astrophysics Data System (ADS)

    Badea, Cristian T.; Johnston, Samuel M.; Qi, Yi; Johnson, G. Allan

    2011-06-01

    Micro-CT is commonly used in preclinical studies to provide anatomical information. There is growing interest in obtaining functional measurements from 4D micro-CT. We report here strategies for 4D micro-CT with a focus on two applications: (i) cardiac imaging based on retrospective gating and (ii) pulmonary perfusion using multiple contrast injections/rotations paradigm. A dual source micro-CT system is used for image acquisition with a sampling rate of 20 projections per second. The cardiac micro-CT protocol involves the use of a liposomal blood pool contrast agent. Fast scanning of free breathing mice is achieved using retrospective gating. The ECG and respiratory signals are used to sort projections into ten cardiac phases. The pulmonary perfusion protocol uses a conventional contrast agent (Isovue 370) delivered by a micro-injector in four injections separated by 2 min intervals to allow for clearance. Each injection is synchronized with the rotation of the animal, and each of the four rotations is started with an angular offset of 22.5 from the starting angle of the previous rotation. Both cardiac and perfusion protocols result in an irregular angular distribution of projections that causes significant streaking artifacts in reconstructions when using traditional filtered backprojection (FBP) algorithms. The reconstruction involves the use of the point spread function of the micro-CT system for each time point, and the analysis of the distribution of the reconstructed data in the Fourier domain. This enables us to correct for angular inconsistencies via deconvolution and identify regions where data is missing. The missing regions are filled with data from a high quality but temporally averaged prior image reconstructed with all available projections. Simulations indicate that deconvolution successfully removes the streaking artifacts while preserving temporal information. 4D cardiac micro-CT in a mouse was performed with adequate image quality at isotropic

  13. Constrain static target kinetic iterative image reconstruction for 4D cardiac CT imaging

    NASA Astrophysics Data System (ADS)

    Alessio, Adam M.; La Riviere, Patrick J.

    2011-03-01

    Iterative image reconstruction offers improved signal to noise properties for CT imaging. A primary challenge with iterative methods is the substantial computation time. This computation time is even more prohibitive in 4D imaging applications, such as cardiac gated or dynamic acquisition sequences. In this work, we propose only updating the time-varying elements of a 4D image sequence while constraining the static elements to be fixed or slowly varying in time. We test the method with simulations of 4D acquisitions based on measured cardiac patient data from a) a retrospective cardiac-gated CT acquisition and b) a dynamic perfusion CT acquisition. We target the kinetic elements with one of two methods: 1) position a circular ROI on the heart, assuming area outside ROI is essentially static throughout imaging time; and 2) select varying elements from the coefficient of variation image formed from fast analytic reconstruction of all time frames. Targeted kinetic elements are updated with each iteration, while static elements remain fixed at initial image values formed from the reconstruction of data from all time frames. Results confirm that the computation time is proportional to the number of targeted elements; our simulations suggest that <30% of elements need to be updated in each frame leading to >3 times reductions in reconstruction time. The images reconstructed with the proposed method have matched mean square error with full 4D reconstruction. The proposed method is amenable to most optimization algorithms and offers the potential for significant computation improvements, which could be traded off for more sophisticated system models or penalty terms.

  14. SU-C-9A-06: The Impact of CT Image Used for Attenuation Correction in 4D-PET

    SciTech Connect

    Cui, Y; Bowsher, J; Yan, S; Cai, J; Das, S; Yin, F

    2014-06-01

    Purpose: To evaluate the appropriateness of using 3D non-gated CT image for attenuation correction (AC) in a 4D-PET (gated PET) imaging protocol used in radiotherapy treatment planning simulation. Methods: The 4D-PET imaging protocol in a Siemens PET/CT simulator (Biograph mCT, Siemens Medical Solutions, Hoffman Estates, IL) was evaluated. CIRS Dynamic Thorax Phantom (CIRS Inc., Norfolk, VA) with a moving glass sphere (8 mL) in the middle of its thorax portion was used in the experiments. The glass was filled with {sup 18}F-FDG and was in a longitudinal motion derived from a real patient breathing pattern. Varian RPM system (Varian Medical Systems, Palo Alto, CA) was used for respiratory gating. Both phase-gating and amplitude-gating methods were tested. The clinical imaging protocol was modified to use three different CT images for AC in 4D-PET reconstruction: first is to use a single-phase CT image to mimic actual clinical protocol (single-CT-PET); second is to use the average intensity projection CT (AveIP-CT) derived from 4D-CT scanning (AveIP-CT-PET); third is to use 4D-CT image to do the phase-matched AC (phase-matching- PET). Maximum SUV (SUVmax) and volume of the moving target (glass sphere) with threshold of 40% SUVmax were calculated for comparison between 4D-PET images derived with different AC methods. Results: The SUVmax varied 7.3%±6.9% over the breathing cycle in single-CT-PET, compared to 2.5%±2.8% in AveIP-CT-PET and 1.3%±1.2% in phasematching PET. The SUVmax in single-CT-PET differed by up to 15% from those in phase-matching-PET. The target volumes measured from single- CT-PET images also presented variations up to 10% among different phases of 4D PET in both phase-gating and amplitude-gating experiments. Conclusion: Attenuation correction using non-gated CT in 4D-PET imaging is not optimal process for quantitative analysis. Clinical 4D-PET imaging protocols should consider phase-matched 4D-CT image if available to achieve better accuracy.

  15. 4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT.

    PubMed

    Pan, Tinsu; Lee, Ting-Yim; Rietzel, Eike; Chen, George T Y

    2004-02-01

    We propose a new scanning protocol for generating 4D-CT image data sets influenced by respiratory motion. A cine scanning protocol is used during data acquisition, and two registration methods are used to sort images into temporal phases. A volume is imaged in multiple acquisitions of 1 or 2 cm length along the cranial-caudal direction. In each acquisition, the scans are continuously acquired for a time interval greater than or equal to the average respiratory cycle plus the duration of the data for an image reconstruction. The x ray is turned off during CT table translation and the acquisition is repeated until the prescribed volume is completely scanned. The scanning for 20 cm coverage takes about 1 min with an eight-slice CT or 2 mins with a four-slice CT. After data acquisition, the CT data are registered into respiratory phases based on either an internal anatomical match or an external respiratory signal. The internal approach registers the data according to correlation of anatomy in the CT images between two adjacent locations in consecutive respiratory cycles. We have demonstrated the technique with ROIs placed in the region of diaphragm. The external approach registers the image data according to an externally recorded respiratory signal generated by the Real-Time Position Management (RPM) Respiratory Gating System (Varian Medical Systems, Palo Alto, CA). Compared with previously reported prospective or retrospective imaging of the respiratory motion with a single-slice or multi-slice CT, the 4D-CT method proposed here provides (1) a shorter scan time of three to six times faster than the single-slice CT with prospective gating; (2) a shorter scan time of two to four times improvement over a previously reported multi-slice CT implementation, and (3) images over all phases of a breathing cycle. We have applied the scanning and registration methods on phantom, animal and patients, and initial results suggest the applicability of both the scanning and the

  16. 4D micro-CT-based perfusion imaging in small animals

    NASA Astrophysics Data System (ADS)

    Badea, C. T.; Johnston, S. M.; Lin, M.; Hedlund, L. W.; Johnson, G. A.

    2009-02-01

    Quantitative in-vivo imaging of lung perfusion in rodents can provide critical information for preclinical studies. However, the combined challenges of high temporal and spatial resolution have made routine quantitative perfusion imaging difficult in rodents. We have recently developed a dual tube/detector micro-CT scanner that is well suited to capture first-pass kinetics of a bolus of contrast agent used to compute perfusion information. Our approach is based on the paradigm that the same time density curves can be reproduced in a number of consecutive, small (i.e. 50μL) injections of iodinated contrast agent at a series of different angles. This reproducibility is ensured by the high-level integration of the imaging components of our system, with a micro-injector, a mechanical ventilator, and monitoring applications. Sampling is controlled through a biological pulse sequence implemented in LabVIEW. Image reconstruction is based on a simultaneous algebraic reconstruction technique implemented on a GPU. The capabilities of 4D micro-CT imaging are demonstrated in studies on lung perfusion in rats. We report 4D micro-CT imaging in the rat lung with a heartbeat temporal resolution of 140 ms and reconstructed voxels of 88 μm. The approach can be readily extended to a wide range of important preclinical models, such as tumor perfusion and angiogenesis, and renal function.

  17. Estimation of lung motion fields in 4D CT data by variational non-linear intensity-based registration: A comparison and evaluation study.

    PubMed

    Werner, René; Schmidt-Richberg, Alexander; Handels, Heinz; Ehrhardt, Jan

    2014-08-01

    Accurate and robust estimation of motion fields in respiration-correlated CT (4D CT) images, usually performed by non-linear registration of the temporal CT frames, is a precondition for the analysis of patient-specific breathing dynamics and subsequent image-supported diagnostics and treatment planning. In this work, we present a comprehensive comparison and evaluation study of non-linear registration variants applied to the task of lung motion estimation in thoracic 4D CT data. In contrast to existing multi-institutional comparison studies (e.g. MIDRAS and EMPIRE10), we focus on the specific but common class of variational intensity-based non-parametric registration and analyze the impact of the different main building blocks of the underlying optimization problem: the distance measure to be minimized, the regularization approach and the transformation space considered during optimization. In total, 90 different combinations of building block instances are compared. Evaluated on proprietary and publicly accessible 4D CT images, landmark-based registration errors (TRE) between 1.14 and 1.20 mm for the most accurate registration variants demonstrate competitive performance of the applied general registration framework compared to other state-of-the-art approaches for lung CT registration. Although some specific trends can be observed, effects of interchanging individual instances of the building blocks on the TRE are in general rather small (no single outstanding registration variant existing); the same level of accuracy is, however, associated with significantly different degrees of motion field smoothness and computational demands. Consequently, the building block combination of choice will depend on application-specific requirements on motion field characteristics.

  18. Technical evaluation of different respiratory monitoring systems used for 4D CT acquisition under free breathing.

    PubMed

    Heinz, Christian; Reiner, Michael; Belka, Claus; Walter, Franziska; Söhn, Matthias

    2015-03-08

    Respiratory monitoring systems are required to supply CT scanners with information on the patient's breathing during the acquisition of a respiration-correlated computer tomography (RCCT), also referred to as 4D CT. The information a respiratory monitoring system has to provide to the CT scanner depends on the specific scanner. The purpose of this study is to compare two different respiratory monitoring systems (Anzai Respiratory Gating System; C-RAD Sentinel) with respect to their applicability in combination with an Aquilion Large Bore CT scanner from Toshiba. The scanner used in our clinic does not make use of the full time dependent breathing signal, but only single trigger pulses indicating the beginning of a new breathing cycle. Hence the attached respiratory monitoring system is expected to deliver accurate online trigger pulse for each breathing cycle. The accuracy of the trigger pulses sent to the CT scanner has to be ensured by the selected respiratory monitoring system. Since a trigger pulse (output signal) of a respiratory monitoring system is a function of the measured breathing signal (input signal), the typical clinical range of the input signal is estimated for both examined respiratory monitoring systems. Both systems are analyzed based on the following parameters: time resolution, signal amplitude, noise, signal-to-noise ratio (SNR), signal linearity, trigger compatibility, and clinical examples. The Anzai system shows a better SNR (≥ 28 dB) than the Sentinel system (≥ 14.6 dB). In terms of compatibility with the cycle-based image sorting algorithm of the Toshiba CT scanner, the Anzai system benefits from the possibility to generate cycle-based triggers, whereas the Sentinel system is only able to generate amplitude-based triggers. In clinical practice, the combination of a Toshiba CT scanner and the Anzai system will provide better results due to the compatibility of the image sorting and trigger release methods.

  19. Registration-based segmentation of murine 4D cardiac micro-CT data using symmetric normalization

    PubMed Central

    Clark, Darin; Badea, Alexandra; Liu, Yilin; Johnson, G. Allan; Badea, Cristian T.

    2013-01-01

    Micro-CT can play an important role in preclinical studies of cardiovascular disease because of its high spatial and temporal resolution. Quantitative analysis of 4D cardiac images requires segmentation of the cardiac chambers at each time point, an extremely time consuming process if done manually. To improve throughput this study proposes a pipeline for registration-based segmentation and functional analysis of 4D cardiac micro-CT data in the mouse. Following optimization and validation using simulations, the pipeline was applied to in vivo cardiac micro-CT data corresponding to 10 cardiac phases acquired in C57BL/6 mice (n = 5). After edge-preserving smoothing with a novel adaptation of 4D bilateral filtration, one phase within each cardiac sequence was manually segmented. Deformable registration was used to propagate these labels to all other cardiac phases for segmentation. The volumes of each cardiac chamber were calculated and used to derive stroke volume, ejection fraction, cardiac output, and cardiac index. Dice coefficients and volume accuracies were used to compare manual segmentations of two additional phases with their corresponding propagated labels. Both measures were, on average, >0.90 for the left ventricle and >0.80 for the myocardium, the right ventricle, and the right atrium, consistent with trends in inter- and intra-segmenter variability. Segmentation of the left atrium was less reliable. On average, the functional metrics of interest were underestimated by 6.76% or more due to systematic label propagation errors around atrioventricular valves; however, execution of the pipeline was 80% faster than performing analogous manual segmentation of each phase. PMID:22971564

  20. Enhanced 4D cone-beam CT with inter-phase motion model.

    PubMed

    Li, Tianfang; Koong, Albert; Xing, Lei

    2007-09-01

    Four-dimensional (4D) cone-beam CT (CBCT) is commonly obtained by respiratory phase binning of the projections, followed by independent reconstructions of the rebinned data in each phase bin. Due to the significantly reduced number of projections per reconstruction, the quality of the 4DCBCT images is often degraded by view-aliasing artifacts easily seen in the axial view. Acquisitions using multiple gantry rotations or slow gantry rotation can increase the number of projections and substantially improve the 4D images. However, the extra cost of the scan time may set fundamental limits to their applications in clinics. Improving the trade-off between image quality and scan time is the key to making 4D onboard imaging practical and more useful. In this article, we present a novel technique toward high-quality 4DCBCT imaging without prolonging the acquisition time, referred to as the "enhanced 4DCBCT". The method correlates the data in different phase bins and integrates the internal motion into the 4DCBCT image formulation. Several strategies of the motion derivation are discussed, and the resultant images are assessed with numerical simulations as well as a clinical case.

  1. 4D-Imaging of the Lung: Reproducibility of Lesion Size and Displacement on Helical CT, MRI, and Cone Beam CT in a Ventilated Ex Vivo System

    SciTech Connect

    Biederer, Juergen Dinkel, Julien; Remmert, Gregor; Jetter, Siri; Nill, Simeon; Moser, Torsten; Bendl, Rolf; Thierfelder, Carsten; Fabel, Michael; Oelfke, Uwe; Bock, Michael; Plathow, Christian; Bolte, Hendrik; Welzel, Thomas; Hoffmann, Beata; Hartmann, Guenter; Schlegel, Wolfgang; Debus, Juergen; Heller, Martin

    2009-03-01

    Purpose: Four-dimensional (4D) imaging is a key to motion-adapted radiotherapy of lung tumors. We evaluated in a ventilated ex vivo system how size and displacement of artificial pulmonary nodules are reproduced with helical 4D-CT, 4D-MRI, and linac-integrated cone beam CT (CBCT). Methods and Materials: Four porcine lungs with 18 agarose nodules (mean diameters 1.3-1.9 cm), were ventilated inside a chest phantom at 8/min and subject to 4D-CT (collimation 24 x 1.2 mm, pitch 0.1, slice/increment 24x10{sup 2}/1.5/0.8 mm, pitch 0.1, temporal resolution 0.5 s), 4D-MRI (echo-shared dynamic three-dimensional-flash; repetition/echo time 2.13/0.72 ms, voxel size 2.7 x 2.7 x 4.0 mm, temporal resolution 1.4 s) and linac-integrated 4D-CBCT (720 projections, 3-min rotation, temporal resolution {approx}1 s). Static CT without respiration served as control. Three observers recorded lesion size (RECIST-diameters x/y/z) and axial displacement. Interobserver- and interphase-variation coefficients (IO/IP VC) of measurements indicated reproducibility. Results: Mean x/y/z lesion diameters in cm were equal on static and dynamic CT (1.88/1.87; 1.30/1.39; 1.71/1.73; p > 0.05), but appeared larger on MRI and CBCT (2.06/1.95 [p < 0.05 vs. CT]; 1.47/1.28 [MRI vs. CT/CBCT p < 0.05]; 1.86/1.83 [CT vs. CBCT p < 0.05]). Interobserver-VC for lesion sizes were 2.54-4.47% (CT), 2.29-4.48% (4D-CT); 5.44-6.22% (MRI) and 4.86-6.97% (CBCT). Interphase-VC for lesion sizes ranged from 2.28% (4D-CT) to 10.0% (CBCT). Mean displacement in cm decreased from static CT (1.65) to 4D-CT (1.40), CBCT (1.23) and MRI (1.16). Conclusions: Lesion sizes are exactly reproduced with 4D-CT but overestimated on 4D-MRI and CBCT with a larger variability due to limited temporal and spatial resolution. All 4D-modalities underestimate lesion displacement.

  2. Reconstruction of 4D-CT data sets acquired during free breathing for the analysis of respiratory motion

    NASA Astrophysics Data System (ADS)

    Ehrhardt, Jan; Werner, Rene; Frenzel, Thorsten; Säring, Dennis; Lu, Wei; Low, Daniel; Handels, Heinz

    2006-03-01

    Respiratory motion is a significant source of error in radiotherapy treatment planning. 4D-CT data sets can be useful to measure the impact of organ motion caused by breathing. But modern CT scanners can only scan a limited region of the body simultaneously and patients have to be scanned in segments consisting of multiple slices. For studying free breathing motion multislice CT scans can be collected simultaneously with digital spirometry over several breathing cycles. The 4D data set is assembled by sorting the free breathing multislice CT scans according to the couch position and the tidal volume. But artifacts can occur because there are no data segments for exactly the same tidal volume and all couch positions. We present an optical flow based method for the reconstruction of 4D-CT data sets from multislice CT scans, which are collected simultaneously with digital spirometry. The optical flow between the scans is estimated by a non-linear registration method. The calculated velocity field is used to reconstruct a 4D-CT data set by interpolating data at user-defined tidal volumes. By this technique, artifacts can be reduced significantly. The reconstructed 4D-CT data sets are used for studying inner organ motion during the respiratory cycle. The procedures described were applied to reconstruct 4D-CT data sets for four tumour patients who have been scanned during free breathing. The reconstructed 4D data sets were used to quantify organ displacements and to visualize the abdominothoracic organ motion.

  3. Analysis of the advantage of individual PTVs defined on axial 3D CT and 4D CT images for liver cancer.

    PubMed

    Li, Fengxiang; Li, Jianbin; Xing, Jun; Zhang, Yingjie; Fan, Tingyong; Xu, Min; Shang, Dongping; Liu, Tonghai; Song, Jinlong

    2012-11-08

    The purpose of this study was to compare positional and volumetric differences of planning target volumes (PTVs) defined on axial three dimensional CT (3D CT) and four dimensional CT (4D CT) for liver cancer. Fourteen patients with liver cancer underwent 3D CT and 4D CT simulation scans during free breathing. The tumor motion was measured by 4D CT. Three internal target volumes (ITVs) were produced based on the clinical target volume from 3DCT (CTV3D): i) A conventional ITV (ITVconv) was produced by adding 10 mm in CC direction and 5 mm in LR and and AP directions to CTV3D; ii) A specific ITV (ITVspec) was created using a specific margin in transaxial direction; iii) ITVvector was produced by adding an isotropic margin derived from the individual tumor motion vector. ITV4D was defined on the fusion of CTVs on all phases of 4D CT. PTVs were generated by adding a 5 mm setup margin to ITVs. The average centroid shifts between PTVs derived from 3DCT and PTV4D in left-right (LR), anterior-posterior (AP), and cranial-caudal (CC) directions were close to zero. Comparing PTV4D to PTVconv, PTVspec, and PTVvector resulted in a decrease in volume size by 33.18% ± 12.39%, 24.95% ± 13.01%, 48.08% ± 15.32%, respectively. The mean degree of inclusions (DI) of PTV4D in PTVconv, and PTV4D in PTVspec, and PTV4D in PTVvector was 0.98, 0.97, and 0.99, which showed no significant correlation to tumor motion vector (r = -0.470, 0.259, and 0.244; p = 0.090, 0.371, and 0.401). The mean DIs of PTVconv in PTV4D, PTVspec in PTV4D, and PTVvector in PTV4D was 0.66, 0.73, and 0.52. The size of individual PTV from 4D CT is significantly less than that of PTVs from 3DCT. The position of targets derived from axial 3DCT images scatters around the center of 4D targets randomly. Compared to conventional PTV, the use of 3D CT-based PTVs with individual margins cannot significantly reduce normal tissues being unnecessarily irradiated, but may contribute to reducing the risk of missing targets for

  4. Reference geometry-based detection of (4D-)CT motion artifacts: a feasibility study

    NASA Astrophysics Data System (ADS)

    Werner, René; Gauer, Tobias

    2015-03-01

    Respiration-correlated computed tomography (4D or 3D+t CT) can be considered as standard of care in radiation therapy treatment planning for lung and liver lesions. The decision about an application of motion management devices and the estimation of patient-specific motion effects on the dose distribution relies on precise motion assessment in the planning 4D CT data { which is impeded in case of CT motion artifacts. The development of image-based/post-processing approaches to reduce motion artifacts would benefit from precise detection and localization of the artifacts. Simple slice-by-slice comparison of intensity values and threshold-based analysis of related metrics suffer from- depending on the threshold- high false-positive or -negative rates. In this work, we propose exploiting prior knowledge about `ideal' (= artifact free) reference geometries to stabilize metric-based artifact detection by transferring (multi-)atlas-based concepts to this specific task. Two variants are introduced and evaluated: (S1) analysis and comparison of warped atlas data obtained by repeated non-linear atlas-to-patient registration with different levels of regularization; (S2) direct analysis of vector field properties (divergence, curl magnitude) of the atlas-to-patient transformation. Feasibility of approaches (S1) and (S2) is evaluated by motion-phantom data and intra-subject experiments (four patients) as well as - adopting a multi-atlas strategy- inter-subject investigations (twelve patients involved). It is demonstrated that especially sorting/double structure artifacts can be precisely detected and localized by (S1). In contrast, (S2) suffers from high false positive rates.

  5. Semiautomatic method to identify the best phase for gated RT in lung region by 4D-PET/CT acquisitions

    SciTech Connect

    Mancosu, Pietro; Danna, Massimo; Bettinardi, Valentino; Aquilina, Mark Anthony; Lobefalo, Francesca; Cozzi, Luca; Fogliata, Antonella; Scorsetti, Marta

    2011-01-15

    Purpose: Delineating tumor motion by four-dimensional positron emission tomography/computed tomography (4D-PET/CT) is a crucial step for gated radiotherapy (RT). This article quantitatively evaluates semiautomatic algorithms for tumor shift estimation in the lung region due to patient respiration by 4D-PET/CT, in order to support the selection of the best phases for gated RT, by considering the most stable phases of the breathing cycle. Methods: Three mobile spheres and ten selected lesions were included in this study. 4D-PET/CT data were reconstructed and classified into six/ten phases. The semiautomatic algorithms required the generation of single sets of images representative of the full target motion, used as masks for segmenting the phases. For 4D-CT, a pre-established HU range was used, whereas three thresholds (100%, 80%, and 40%) were evaluated for 4D-PET. By using these segmentations, the authors estimated the lesion motion from the shifting centroids, and the phases with the least motion were also deduced including the phases with a curve slope less than 2 mm/{Delta}phase. The proposed algorithms were validated by comparing the results to those generated entirely by manual contouring. Results: In the phantom study, the mean difference between the manual contour and the semiautomatic technique was 0.1{+-}0.1 mm for 4D-CT and 0.2{+-}0.1 mm for the 4D-PET based on 40% threshold. In the patients' series, the mean difference was 0.9{+-}0.6 mm for 4D-CT and 0.8{+-}0.2 mm for the 4D-PET based on 40% threshold. Conclusions: Estimation of lesion motion by the proposed semiautomatic algorithm can be used to evaluate tumor motion due to breathing.

  6. Spatial-temporal total variation regularization (STTVR) for 4D-CT reconstruction

    NASA Astrophysics Data System (ADS)

    Wu, Haibo; Maier, Andreas; Fahrig, Rebecca; Hornegger, Joachim

    2012-03-01

    Four dimensional computed tomography (4D-CT) is very important for treatment planning in thorax or abdomen area, e.g. for guiding radiation therapy planning. The respiratory motion makes the reconstruction problem illposed. Recently, compressed sensing theory was introduced. It uses sparsity as a prior to solve the problem and improves image quality considerably. However, the images at each phase are reconstructed individually. The correlations between neighboring phases are not considered in the reconstruction process. In this paper, we propose the spatial-temporal total variation regularization (STTVR) method which not only employs the sparsity in the spatial domain but also in the temporal domain. The algorithm is validated with XCAT thorax phantom. The Euclidean norm of the reconstructed image and ground truth is calculated for evaluation. The results indicate that our method improves the reconstruction quality by more than 50% compared to standard ART.

  7. Linac-integrated 4D cone beam CT: first experimental results

    NASA Astrophysics Data System (ADS)

    Dietrich, Lars; Jetter, Siri; Tücking, Thomas; Nill, Simeon; Oelfke, Uwe

    2006-06-01

    A new online imaging approach, linac-integrated cone beam CT (CBCT), has been developed over the past few years. It has the advantage that a patient can be examined in their treatment position directly before or during a radiotherapy treatment. Unfortunately, respiratory organ motion, one of the largest intrafractional organ motions, often leads to artefacts in the reconstructed 3D images. One way to take this into account is to register the breathing phase during image acquisition for a phase-correlated image reconstruction. Therefore, the main focus of this work is to present a system which has the potential to investigate the correlation between internal (movement of the diaphragm) and external (data of a respiratory gating system) information about breathing phase and amplitude using an inline CBCT scanner. This also includes a feasibility study about using the acquired information for a respiratory-correlated 4D CBCT reconstruction. First, a moving lung phantom was used to develop and to specify the required methods which are based on an image reconstruction using only projections belonging to a certain moving phase. For that purpose, the corresponding phase has to be detected for each projection. In the case of the phantom, an electrical signal allows one to track the movement in real time. The number of projections available for the image reconstruction depends on the breathing phase and the size of the position range from which projections should be used for the reconstruction. The narrower this range is, the better the inner structures can be located, but also the noise of the images increases due to the limited number of projections. This correlation has also been analysed. In a second step, the methods were clinically applied using data sets of patients with lung tumours. In this case, the breathing phase was detected by an external gating system (AZ-733V, Anzai Medical Co.) based on a pressure sensor attached to the patient's abdominal region with a

  8. Comparison of an alternative and existing binning methods to reduce the acquisition duration of 4D PET/CT

    SciTech Connect

    Didierlaurent, David Ribes, Sophie; Caselles, Olivier; Jaudet, Cyril; Dierickx, Lawrence O.; Zerdoud, Slimane; Brillouet, Severine; Weits, Kathleen; Batatia, Hadj; Courbon, Frédéric

    2014-11-01

    Purpose: Respiratory motion is a source of artifacts that reduce image quality in PET. Four dimensional (4D) PET/CT is one approach to overcome this problem. Existing techniques to limiting the effects of respiratory motions are based on prospective phase binning which requires a long acquisition duration (15–25 min). This time is uncomfortable for the patients and limits the clinical exploitation of 4D PET/CT. In this work, the authors evaluated an existing method and an alternative retrospective binning method to reduce the acquisition duration of 4D PET/CT. Methods: The authors studied an existing mixed-amplitude binning (MAB) method and an alternative binning method by mixed-phases (MPhB). Before implementing MPhB, they analyzed the regularity of the breathing patterns in patients. They studied the breathing signal drift and missing CT slices that could be challenging for implementing MAB. They compared the performance of MAB and MPhB with current binning methods to measure the maximum uptake, internal volume, and maximal range of tumor motion. Results: MPhB can be implemented depending on an optimal phase (in average, the exhalation peak phase −4.1% of the entire breathing cycle duration). Signal drift of patients was in average 35% relative to the breathing amplitude. Even after correcting this drift, MAB was feasible in 4D CT for only 64% of patients. No significant differences appeared between the different binning methods to measure the maximum uptake, internal volume, and maximal range of tumor motion. The authors also determined the inaccuracies of MAB and MPhB to measure the maximum amplitude of tumor motion with three bins (less than 3 mm for movement inferior to 12 mm, up to 6.4 mm for a 21 mm movement). Conclusions: The authors proposed an alternative binning method by mixed-phase binning that halves the acquisition duration of 4D PET/CT. Mixed-amplitude binning was challenging because of signal drift and missing CT slices. They showed that more

  9. Adaptive patch-based POCS approach for super resolution reconstruction of 4D-CT lung data.

    PubMed

    Wang, Tingting; Cao, Lei; Yang, Wei; Feng, Qianjin; Chen, Wufan; Zhang, Yu

    2015-08-01

    Image enhancement of lung four-dimensional computed tomography (4D-CT) data is highly important because image resolution remains a crucial point in lung cancer radiotherapy. In this paper, we proposed a method for lung 4D-CT super resolution (SR) by using an adaptive-patch-based projection onto convex sets (POCS) approach, which is in contrast with the global POCS SR algorithm, to recover fine details with lesser artifacts in images. The main contribution of this patch-based approach is that the interfering local structure from other phases can be rejected by employing a similar patch adaptive selection strategy. The effectiveness of our approach is demonstrated through experiments on simulated images and real lung 4D-CT datasets. A comparison with previously published SR reconstruction methods highlights the favorable characteristics of the proposed method.

  10. Adaptive patch-based POCS approach for super resolution reconstruction of 4D-CT lung data

    NASA Astrophysics Data System (ADS)

    Wang, Tingting; Cao, Lei; Yang, Wei; Feng, Qianjin; Chen, Wufan; Zhang, Yu

    2015-08-01

    Image enhancement of lung four-dimensional computed tomography (4D-CT) data is highly important because image resolution remains a crucial point in lung cancer radiotherapy. In this paper, we proposed a method for lung 4D-CT super resolution (SR) by using an adaptive-patch-based projection onto convex sets (POCS) approach, which is in contrast with the global POCS SR algorithm, to recover fine details with lesser artifacts in images. The main contribution of this patch-based approach is that the interfering local structure from other phases can be rejected by employing a similar patch adaptive selection strategy. The effectiveness of our approach is demonstrated through experiments on simulated images and real lung 4D-CT datasets. A comparison with previously published SR reconstruction methods highlights the favorable characteristics of the proposed method.

  11. [Super-resolution reconstruction of lung 4D-CT images based on fast sub-pixel motion estimation].

    PubMed

    Xiao, Shan; Wang, Tingting; Lü, Qingwen; Zhang, Yu

    2015-07-01

    Super-resolution image reconstruction techniques play an important role for improving image resolution of lung 4D-CT. We presents a super-resolution approach based on fast sub-pixel motion estimation to reconstruct lung 4D-CT images. A fast sub-pixel motion estimation method was used to estimate the deformation fields between "frames", and then iterative back projection (IBP) algorithm was employed to reconstruct high-resolution images. Experimental results showed that compared with traditional interpolation method and super-resolution reconstruction algorithm based on full search motion estimation, the proposed method produced clearer images with significantly enhanced image structure details and reduced time for computation.

  12. Automatic landmark generation for deformable image registration evaluation for 4D CT images of lung

    NASA Astrophysics Data System (ADS)

    Vickress, J.; Battista, J.; Barnett, R.; Morgan, J.; Yartsev, S.

    2016-10-01

    Deformable image registration (DIR) has become a common tool in medical imaging across both diagnostic and treatment specialties, but the methods used offer varying levels of accuracy. Evaluation of DIR is commonly performed using manually selected landmarks, which is subjective, tedious and time consuming. We propose a semi-automated method that saves time and provides accuracy comparable to manual selection. Three landmarking methods including manual (with two independent observers), scale invariant feature transform (SIFT), and SIFT with manual editing (SIFT-M) were tested on 10 thoracic 4DCT image studies corresponding to the 0% and 50% phases of respiration. Results of each method were evaluated against a gold standard (GS) landmark set comparing both mean and proximal landmark displacements. The proximal method compares the local deformation magnitude between a test landmark pair and the closest GS pair. Statistical analysis was done using an intra class correlation (ICC) between test and GS displacement values. The creation time per landmark pair was 22, 34, 2.3, and 4.3 s for observers 1 and 2, SIFT, and SIFT-M methods respectively. Across 20 lungs from the 10 CT studies, the ICC values between the GS and observer 1 and 2, SIFT, and SIFT-M methods were 0.85, 0.85, 0.84, and 0.82 for mean lung deformation, and 0.97, 0.98, 0.91, and 0.96 for proximal landmark deformation, respectively. SIFT and SIFT-M methods have an accuracy that is comparable to manual methods when tested against a GS landmark set while saving 90% of the time. The number and distribution of landmarks significantly affected the analysis as manifested by the different results for mean deformation and proximal landmark deformation methods. Automatic landmark methods offer a promising alternative to manual landmarking, if the quantity, quality and distribution of landmarks can be optimized for the intended application.

  13. Algorithm of pulmonary emphysema extraction using thoracic 3D CT images

    NASA Astrophysics Data System (ADS)

    Saita, Shinsuke; Kubo, Mitsuru; Kawata, Yoshiki; Niki, Noboru; Nakano, Yasutaka; Ohmatsu, Hironobu; Tominaga, Keigo; Eguchi, Kenji; Moriyama, Noriyuki

    2007-03-01

    Recently, due to aging and smoking, emphysema patients are increasing. The restoration of alveolus which was destroyed by emphysema is not possible, thus early detection of emphysema is desired. We describe a quantitative algorithm for extracting emphysematous lesions and quantitatively evaluate their distribution patterns using low dose thoracic 3-D CT images. The algorithm identified lung anatomies, and extracted low attenuation area (LAA) as emphysematous lesion candidates. Applying the algorithm to thoracic 3-D CT images and then by follow-up 3-D CT images, we demonstrate its potential effectiveness to assist radiologists and physicians to quantitatively evaluate the emphysematous lesions distribution and their evolution in time interval changes.

  14. Spatial correspondence of 4D CT ventilation and SPECT pulmonary perfusion defects in patients with malignant airway stenosis

    NASA Astrophysics Data System (ADS)

    Castillo, Richard; Castillo, Edward; McCurdy, Matthew; Gomez, Daniel R.; Block, Alec M.; Bergsma, Derek; Joy, Sarah; Guerrero, Thomas

    2012-04-01

    To determine the spatial overlap agreement between four-dimensional computed tomography (4D CT) ventilation and single photon emission computed tomography (SPECT) perfusion hypo-functioning pulmonary defect regions in a patient population with malignant airway stenosis. Treatment planning 4D CT images were obtained retrospectively for ten lung cancer patients with radiographically demonstrated airway obstruction due to gross tumor volume. Each patient also received a SPECT perfusion study within one week of the planning 4D CT, and prior to the initiation of treatment. Deformable image registration was used to map corresponding lung tissue elements between the extreme component phase images, from which quantitative three-dimensional (3D) images representing the local pulmonary specific ventilation were constructed. Semi-automated segmentation of the percentile perfusion distribution was performed to identify regional defects distal to the known obstructing lesion. Semi-automated segmentation was similarly performed by multiple observers to delineate corresponding defect regions depicted on 4D CT ventilation. Normalized Dice similarity coefficient (NDSC) indices were determined for each observer between SPECT perfusion and 4D CT ventilation defect regions to assess spatial overlap agreement. Tidal volumes determined from 4D CT ventilation were evaluated versus measurements obtained from lung parenchyma segmentation. Linear regression resulted in a linear fit with slope = 1.01 (R2 = 0.99). Respective values for the average DSC, NDSC1 mm and NDSC2 mm for all cases and multiple observers were 0.78, 0.88 and 0.99, indicating that, on average, spatial overlap agreement between ventilation and perfusion defect regions was comparable to the threshold for agreement within 1-2 mm uncertainty. Corresponding coefficients of variation for all metrics were similarly in the range: 0.10%-19%. This study is the first to quantitatively assess 3D spatial overlap agreement between

  15. Validation of the 4D NCAT simulation tools for use in high-resolution x-ray CT research

    NASA Astrophysics Data System (ADS)

    Segars, W. P.; Mahesh, Mahadevappa; Beck, T.; Frey, E. C.; Tsui, B. M. W.

    2005-04-01

    We validate the computer-based simulation tools developed in our laboratory for use in high-resolution CT research. The 4D NURBS-based cardiac-torso (NCAT) phantom was developed to provide a realistic and flexible model of the human anatomy and physiology. Unlike current phantoms in CT, the 4D NCAT has the advantage, due to its design, that its organ shapes can be changed to realistically model anatomical variations and patient motion. To efficiently simulate high-resolution CT images, we developed a unique analytic projection algorithm (including scatter and quantum noise) to accurately calculate projections directly from the surface definition of the phantom given parameters defining the CT scanner and geometry. The projection data are reconstructed into CT images using algorithms developed in our laboratory. The 4D NCAT phantom contains a level of detail that is close to impossible to produce in a physical test object. We, therefore, validate our CT simulation tools and methods through a series of direct comparisons with data obtained experimentally using existing, simple physical phantoms at different doses and using different x-ray energy spectra. In each case, the first-order simulations were found to produce comparable results (<12%). We reason that since the simulations produced equivalent results using simple test objects, they should be able to do the same in more anatomically realistic conditions. We conclude that, with the ability to provide realistic simulated CT image data close to that from actual patients, the simulation tools developed in this work will have applications in a broad range of CT imaging research.

  16. Assessment of tumor motion reproducibility with audio-visual coaching through successive 4D CT sessions.

    PubMed

    Goossens, Samuel; Senny, Frédéric; Lee, John A; Janssens, Guillaume; Geets, Xavier

    2014-01-04

    This study aimed to compare combined audio-visual coaching with audio coaching alone and assess their respective impact on the reproducibility of external breathing motion and, one step further, on the internal lung tumor motion itself, through successive sessions. Thirteen patients with NSCLC were enrolled in this study. The tumor motion was assessed by three to four successive 4D CT sessions, while the breathing signal was measured from magnetic sensors positioned on the epigastric region. For all sessions, the breathing was regularized with either audio coaching alone (AC, n = 5) or combined with a real-time visual feedback (A/VC, n = 8) when tolerated by the patients. Peak-to-peak amplitude, period and signal shape of both breathing and tumor motions were first measured. Then, the correlation between the respiratory signal and internal tumor motion over time was evaluated, as well as the residual tumor motion for a gated strategy. Although breathing and tumor motions were comparable between AC and AV/C groups, A/VC approach achieved better reproducibility through sessions than AC alone (mean tumor motion of 7.2 mm ± 1 vs. 8.6 mm ± 1.8 mm, and mean breathing motion of 14.9 mm ± 1.2 mm vs. 13.3mm ± 3.7 mm, respectively). High internal/external correlation reproducibility was achieved in the superior-inferior tumor motion direction for all patients. For the anterior posterior tumor motion direction, better correlation reproducibility has been observed when visual feedback has been used. For a displacement-based gating approach, A/VC might also be recommended, since it led to smaller residual tumor motion within clinically relevant duty cycles. This study suggests that combining real-time visual feedback with audio coaching might improve the reproducibility of key characteristics of the breathing pattern, and might thus be considered in the implementation of lung tumor radiotherapy.

  17. A novel CT-FFR method for the coronary artery based on 4D-CT image analysis and structural and fluid analysis

    NASA Astrophysics Data System (ADS)

    Hirohata, K.; Kano, A.; Goryu, A.; Ooga, J.; Hongo, T.; Higashi, S.; Fujisawa, Y.; Wakai, S.; Arakita, K.; Ikeda, Y.; Kaminaga, S.; Ko, B. S.; Seneviratne, S. K.

    2015-03-01

    Non invasive fractional flow reserve derived from CT coronary angiography (CT-FFR) has to date been typically performed using the principles of fluid analysis in which a lumped parameter coronary vascular bed model is assigned to represent the impedance of the downstream coronary vascular networks absent in the computational domain for each coronary outlet. This approach may have a number of limitations. It may not account for the impact of the myocardial contraction and relaxation during the cardiac cycle, patient-specific boundary conditions for coronary artery outlets and vessel stiffness. We have developed a novel approach based on 4D-CT image tracking (registration) and structural and fluid analysis, to address these issues. In our approach, we analyzed the deformation variation of vessels and the volume variation of vessels, primarily from 70% to 100% of cardiac phase, to better define boundary conditions and stiffness of vessels. We used a statistical estimation method based on a hierarchical Bayes model to integrate 4D-CT measurements and structural and fluid analysis data. Under these analysis conditions, we performed structural and fluid analysis to determine pressure, flow rate and CT-FFR. The consistency of this method has been verified by a comparison of 4D-CTFFR analysis results derived from five clinical 4D-CT datasets with invasive measurements of FFR. Additionally, phantom experiments of flexible tubes with/without stenosis using pulsating pumps, flow sensors and pressure sensors were performed. Our results show that the proposed 4D-CT-FFR analysis method has the potential to accurately estimate the effect of coronary artery stenosis on blood flow.

  18. High-performance C-arm cone-beam CT guidance of thoracic surgery

    NASA Astrophysics Data System (ADS)

    Schafer, Sebastian; Otake, Yoshito; Uneri, Ali; Mirota, Daniel J.; Nithiananthan, Sajendra; Stayman, J. W.; Zbijewski, Wojciech; Kleinszig, Gerhard; Graumann, Rainer; Sussman, Marc; Siewerdsen, Jeffrey H.

    2012-02-01

    Localizing sub-palpable nodules in minimally invasive video-assisted thoracic surgery (VATS) presents a significant challenge. To overcome inherent problems of preoperative nodule tagging using CT fluoroscopic guidance, an intraoperative C-arm cone-beam CT (CBCT) image-guidance system has been developed for direct localization of subpalpable tumors in the OR, including real-time tracking of surgical tools (including thoracoscope), and video-CBCT registration for augmentation of the thoracoscopic scene. Acquisition protocols for nodule visibility in the inflated and deflated lung were delineated in phantom and animal/cadaver studies. Motion compensated reconstruction was implemented to account for motion induced by the ventilated contralateral lung. Experience in CBCT-guided targeting of simulated lung nodules included phantoms, porcine models, and cadavers. Phantom studies defined low-dose acquisition protocols providing contrast-to-noise ratio sufficient for lung nodule visualization, confirmed in porcine specimens with simulated nodules (3-6mm diameter PE spheres, ~100-150HU contrast, 2.1mGy). Nodule visibility in CBCT of the collapsed lung, with reduced contrast according to air volume retention, was more challenging, but initial studies confirmed visibility using scan protocols at slightly increased dose (~4.6-11.1mGy). Motion compensated reconstruction employing a 4D deformation map in the backprojection process reduced artifacts associated with motion blur. Augmentation of thoracoscopic video with renderings of the target and critical structures (e.g., pulmonary artery) showed geometric accuracy consistent with camera calibration and the tracking system (2.4mm registration error). Initial results suggest a potentially valuable role for CBCT guidance in VATS, improving precision in minimally invasive, lungconserving surgeries, avoid critical structures, obviate the burdens of preoperative localization, and improve patient safety.

  19. Can nontriggered thoracic CT be used for coronary artery calcium scoring? A phantom study

    SciTech Connect

    Xie, Xueqian; Greuter, Marcel J. W.; Groen, Jaap M.; Bock, Geertruida H. de; Oudkerk, Matthijs; Jong, Pim A. de; Vliegenthart, Rozemarijn

    2013-08-15

    Purpose: Coronary artery calcium score, traditionally based on electrocardiography (ECG)-triggered computed tomography (CT), predicts cardiovascular risk. However, nontriggered CT is extensively utilized. The study-purpose is to evaluate the in vitro agreement in coronary calcium score between nontriggered thoracic CT and ECG-triggered cardiac CT.Methods: Three artificial coronary arteries containing calcifications of different densities (high, medium, and low), and sizes (large, medium, and small), were studied in a moving cardiac phantom. Two 64-detector CT systems were used. The phantom moved at 0–90 mm/s in nontriggered low-dose CT as index test, and at 0–30 mm/s in ECG-triggered CT as reference. Differences in calcium scores between nontriggered and ECG-triggered CT were analyzed by t-test and 95% confidence interval. The sensitivity to detect calcification was calculated as the percentage of positive calcium scores.Results: Overall, calcium scores in nontriggered CT were not significantly different to those in ECG-triggered CT (p > 0.05). Calcium scores in nontriggered CT were within the 95% confidence interval of calcium scores in ECG-triggered CT, except predominantly at higher velocities (≥50 mm/s) for the high-density and large-size calcifications. The sensitivity for a nonzero calcium score was 100% for large calcifications, but 46%± 11% for small calcifications in nontriggered CT.Conclusions: When performing multiple measurements, good agreement in positive calcium scores is found between nontriggered thoracic and ECG-triggered cardiac CT. Agreement decreases with increasing coronary velocity. From this phantom study, it can be concluded that a high calcium score can be detected by nontriggered CT, and thus, that nontriggered CT likely can identify individuals at high risk of cardiovascular disease. On the other hand, a zero calcium score in nontriggered CT does not reliably exclude coronary calcification.

  20. Management of CT screen-detected lung nodule: the thoracic surgeon perspective

    PubMed Central

    Al-Ayoubi, Adnan M.

    2016-01-01

    Implementation of lung cancer CT screening programs will increase the incidence of pulmonary nodules and require multidisciplinary efforts for devising appropriate treatment plans. The role of the thoracic surgeon is paramount in leading the discussion and shaping the treatment strategies. Management of CT screen-detected lung nodules differ from conventional lung cancer nodules given their smaller size, varied histologies and potentially indolent growth. Here we present a brief overview of the thoracic surgeon’s perspective on the clinical evaluation, diagnostic tests and surgical approach to these nodules in the setting of a comprehensive lung cancer screening program. PMID:27195274

  1. SU-D-207-04: GPU-Based 4D Cone-Beam CT Reconstruction Using Adaptive Meshing Method

    SciTech Connect

    Zhong, Z; Gu, X; Iyengar, P; Mao, W; Wang, J; Guo, X

    2015-06-15

    Purpose: Due to the limited number of projections at each phase, the image quality of a four-dimensional cone-beam CT (4D-CBCT) is often degraded, which decreases the accuracy of subsequent motion modeling. One of the promising methods is the simultaneous motion estimation and image reconstruction (SMEIR) approach. The objective of this work is to enhance the computational speed of the SMEIR algorithm using adaptive feature-based tetrahedral meshing and GPU-based parallelization. Methods: The first step is to generate the tetrahedral mesh based on the features of a reference phase 4D-CBCT, so that the deformation can be well captured and accurately diffused from the mesh vertices to voxels of the image volume. After the mesh generation, the updated motion model and other phases of 4D-CBCT can be obtained by matching the 4D-CBCT projection images at each phase with the corresponding forward projections of the deformed reference phase of 4D-CBCT. The entire process of this 4D-CBCT reconstruction method is implemented on GPU, resulting in significantly increasing the computational efficiency due to its tremendous parallel computing ability. Results: A 4D XCAT digital phantom was used to test the proposed mesh-based image reconstruction algorithm. The image Result shows both bone structures and inside of the lung are well-preserved and the tumor position can be well captured. Compared to the previous voxel-based CPU implementation of SMEIR, the proposed method is about 157 times faster for reconstructing a 10 -phase 4D-CBCT with dimension 256×256×150. Conclusion: The GPU-based parallel 4D CBCT reconstruction method uses the feature-based mesh for estimating motion model and demonstrates equivalent image Result with previous voxel-based SMEIR approach, with significantly improved computational speed.

  2. TH-E-17A-04: Geometric Validation of K-Space Self-Gated 4D-MRI Vs. 4D-CT Using A Respiratory Motion Phantom

    SciTech Connect

    Yue, Y; Fan, Z; Yang, W; Pang, J; McKenzie, E; Deng, Z; Tuli, R; Sandler, H; Li, D; Fraass, B

    2014-06-15

    Purpose: 4D-CT is often limited by motion artifacts, low temporal resolution, and poor phase-based target definition. We recently developed a novel k-space self-gated 4D-MRI technique with high spatial and temporal resolution. The goal here is to geometrically validate 4D-MRI using a MRI-CT compatible respiratory motion phantom and comparison to 4D-CT. Methods: 4D-MRI was acquired using 3T spoiled gradient echo-based 3D projection sequences. Respiratory phases were resolved using self-gated k-space lines as the motion surrogate. Images were reconstructed into 10 temporal bins with 1.56×1.56×1.56mm3. A MRI-CT compatible phantom was designed with a 23mm diameter ball target filled with highconcentration gadolinium(Gd) gel embedded in a 35×40×63mm3 plastic box stabilized with low-concentration Gd gel. The whole phantom was driven by an air pump. Human respiratory motion was mimicked using the controller from a commercial dynamic phantom (RSD). Four breathing settings (rates/depths: 10s/20mm, 6s/15mm, 4s/10mm, 3s/7mm) were scanned with 4D-MRI and 4D-CT (slice thickness 1.25mm). Motion ground-truth was obtained from input signals and real-time video recordings. Reconstructed images were imported into Eclipse(Varian) for target contouring. Volumes and target positions were compared with ground-truth. Initial human study was investigated on a liver patient. Results: 4D-MRI and 4D-CT scans for the different breathing cycles were reconstructed with 10 phases. Target volume in each phase was measured for both 4D-CT and 4D-MRI. Volume percentage difference for the 6.37ml target ranged from 6.67±5.33 to 11.63±5.57 for 4D-CT and from 1.47±0.52 to 2.12±1.60 for 4D-MRI. The Mann-Whitney U-test shows the 4D-MRI is significantly superior to 4D-CT (p=0.021) for phase-based target definition. Centroid motion error ranges were 1.35–1.25mm (4D-CT), and 0.31–0.12mm (4D-MRI). Conclusion: The k-space self-gated 4D-MRI we recently developed can accurately determine phase

  3. Tumor and normal tissue motion in the thorax during respiration: Analysis of volumetric and positional variations using 4D CT

    SciTech Connect

    Weiss, Elisabeth . E-mail: eweiss@mcvh-vcu.edu; Wijesooriya, Krishni; Dill, S. Vaughn; Keall, Paul J.

    2007-01-01

    Purpose: To investigate temporospatial variations of tumor and normal tissue during respiration in lung cancer patients. Methods and Materials: In 14 patients, gross tumor volume (GTV) and normal tissue structures were manually contoured on four-dimensional computed tomography (4D-CT) scans. Structures were evaluated for volume changes, centroid (center of mass) motion, and phase dependence of variations relative to inspiration. Only volumetrically complete structures were used for analysis (lung in 2, heart in 8, all other structures in >10 patients). Results: During respiration, the magnitude of contoured volumes varied up to 62.5% for GTVs, 25.5% for lungs, and 12.6% for hearts. The range of maximum three-dimensional centroid movement for individual patients was 1.3-24.0 mm for GTV, 2.4-7.9 mm for heart, 5.2-12.0 mm for lungs, 0.3-5.5 mm for skin markers, 2.9-10.0 mm for trachea, and 6.6-21.7 mm for diaphragm. During respiration, the centroid positions of normal structures varied relative to the centroid position of the respective GTV by 1.5-8.1 mm for heart, 2.9-9.3 mm for lungs, 1.2-9.2 mm for skin markers, 0.9-7.1 mm for trachea, and 2.7-16.4 mm for diaphragm. Conclusion: Using 4D-CT, volumetric changes, positional alterations as well as changes in the position of contoured structures relative to the GTV were observed with large variations between individual patients. Although the interpretation of 4D-CT data has considerable uncertainty because of 4D-CT artifacts, observer variations, and the limited acquisition time, the findings might have a significant impact on treatment planning.

  4. TH-E-17A-01: Internal Respiratory Surrogate for 4D CT Using Fourier Transform and Anatomical Features

    SciTech Connect

    Hui, C; Suh, Y; Robertson, D; Pan, T; Das, P; Crane, C; Beddar, S

    2014-06-15

    Purpose: To develop a novel algorithm to generate internal respiratory signals for sorting of four-dimensional (4D) computed tomography (CT) images. Methods: The proposed algorithm extracted multiple time resolved features as potential respiratory signals. These features were taken from the 4D CT images and its Fourier transformed space. Several low-frequency locations in the Fourier space and selected anatomical features from the images were used as potential respiratory signals. A clustering algorithm was then used to search for the group of appropriate potential respiratory signals. The chosen signals were then normalized and averaged to form the final internal respiratory signal. Performance of the algorithm was tested in 50 4D CT data sets and results were compared with external signals from the real-time position management (RPM) system. Results: In almost all cases, the proposed algorithm generated internal respiratory signals that visibly matched the external respiratory signals from the RPM system. On average, the end inspiration times calculated by the proposed algorithm were within 0.1 s of those given by the RPM system. Less than 3% of the calculated end inspiration times were more than one time frame away from those given by the RPM system. In 3 out of the 50 cases, the proposed algorithm generated internal respiratory signals that were significantly smoother than the RPM signals. In these cases, images sorted using the internal respiratory signals showed fewer artifacts in locations corresponding to the discrepancy in the internal and external respiratory signals. Conclusion: We developed a robust algorithm that generates internal respiratory signals from 4D CT images. In some cases, it even showed the potential to outperform the RPM system. The proposed algorithm is completely automatic and generally takes less than 2 min to process. It can be easily implemented into the clinic and can potentially replace the use of external surrogates.

  5. Evaluation of the ΔV 4D CT ventilation calculation method using in vivo xenon CT ventilation data and comparison to other methods.

    PubMed

    Zhang, Geoffrey G; Latifi, Kujtim; Du, Kaifang; Reinhardt, Joseph M; Christensen, Gary E; Ding, Kai; Feygelman, Vladimir; Moros, Eduardo G

    2016-01-01

    Ventilation distribution calculation using 4D CT has shown promising potential in several clinical applications. This study evaluated the direct geometric ventilation calculation method, namely the ΔV method, with xenon-enhanced CT (XeCT) ventilation data from four sheep, and compared it with two other published meth-ods, the Jacobian and the Hounsfield unit (HU) methods. Spearman correlation coefficient (SCC) and Dice similarity coefficient (DSC) were used for the evaluation and comparison. The average SCC with one standard deviation was 0.44 ± 0.13 with a range between 0.29 and 0.61 between the XeCT and ΔV ventilation distributions. The average DSC value for lower 30% ventilation volumes between the XeCT and ΔV ventilation distributions was 0.55 ± 0.07 with a range between 0.48 and 0.63. Ventilation difference introduced by deformable image registration errors improved with smoothing. In conclusion, ventilation distributions generated using ΔV-4D CT and deformable image registration are in reasonably agreement with the in vivo XeCT measured ventilation distribution. PMID:27074479

  6. Evaluation of Elekta 4D cone beam CT-based automatic image registration for radiation treatment of lung cancer

    PubMed Central

    Harrison, Amy; Yu, Yan; Xiao, Ying; Werner-Wasik, Maria; Lu, Bo

    2015-01-01

    Objective: The study was aimed to evaluate the precision of Elekta four-dimensional (4D) cone beam CT (CBCT)-based automatic dual-image registrations using different landmarks for clipbox for radiation treatment of lung cancer. Methods: 30 4D CBCT scans from 15 patients were studied. 4D CBCT images were registered with reference CT images using dual-image registration: a clipbox registration and a mask registration. The image registrations performed in clinic using a physician-defined clipbox, were reviewed by physicians, and were taken as the standard. Studies were conducted to evaluate the automatic dual registrations using three kinds of landmarks for clipbox: spine, spine plus internal target volume (ITV) and lung (including as much of the lung as possible). Translational table shifts calculated from the automatic registrations were compared with those of the standard. Results: The mean of the table shift differences in the lateral direction were 0.03, 0.03 and 0.03 cm, for clipboxes based on spine, spine plus ITV and lung, respectively. The mean of the shift differences in the longitudinal direction were 0.08, 0.08 and 0.08 cm, respectively. The mean of the shift differences in the vertical direction were 0.03, 0.03 and 0.03 cm, respectively. Conclusion: The automatic registrations using three different landmarks for clipbox showed similar results. One can use any of the three landmarks in 4D CBCT dual-image registration. Advance in knowledge: The study provides knowledge and recommendations for application of Elekta 4D CBCT image registration in radiation therapy of lung cancer. PMID:26183932

  7. SU-E-J-154: Image Quality Assessment of Contrast-Enhanced 4D-CT for Pancreatic Adenocarcinoma in Radiotherapy Simulation

    SciTech Connect

    Choi, W; Xue, M; Patel, K; Regine, W; Wang, J; D’Souza, W; Lu, W; Kang, M; Klahr, P

    2015-06-15

    Purpose: This study presents quantitative and qualitative assessment of the image qualities in contrast-enhanced (CE) 3D-CT, 4D-CT and CE 4D-CT to identify feasibility for replacing the clinical standard simulation with a single CE 4D-CT for pancreatic adenocarcinoma (PDA) in radiotherapy simulation. Methods: Ten PDA patients were enrolled and underwent three CT scans: a clinical standard pair of CE 3D-CT immediately followed by a 4D-CT, and a CE 4D-CT one week later. Physicians qualitatively evaluated the general image quality and regional vessel definitions and gave a score from 1 to 5. Next, physicians delineated the contours of the tumor (T) and the normal pancreatic parenchyma (P) on the three CTs (CE 3D-CT, 50% phase for 4D-CT and CE 4D-CT), then high density areas were automatically removed by thresholding at 500 HU and morphological operations. The pancreatic tumor contrast-to-noise ratio (CNR), signal-tonoise ratio (SNR) and conspicuity (C, absolute difference of mean enhancement levels in P and T) were computed to quantitatively assess image quality. The Wilcoxon rank sum test was used to compare these quantities. Results: In qualitative evaluations, CE 3D-CT and CE 4D-CT scored equivalently (4.4±0.4 and 4.3±0.4) and both were significantly better than 4D-CT (3.1±0.6). In quantitative evaluations, the C values were higher in CE 4D-CT (28±19 HU, p=0.19 and 0.17) than the clinical standard pair of CE 3D-CT and 4D-CT (17±12 and 16±17 HU, p=0.65). In CE 3D-CT and CE 4D-CT, mean CNR (1.8±1.4 and 1.8±1.7, p=0.94) and mean SNR (5.8±2.6 and 5.5±3.2, p=0.71) both were higher than 4D-CT (CNR: 1.1±1.3, p<0.3; SNR: 3.3±2.1, p<0.1). The absolute enhancement levels for T and P were higher in CE 4D-CT (87, 82 HU) than in CE 3D-CT (60, 56) and 4DCT (53, 70). Conclusions: The individually optimized CE 4D-CT is feasible and achieved comparable image qualities to the clinical standard simulation. This study was supported in part by Philips Healthcare.

  8. Assessing Cardiac Injury in Mice With Dual Energy-MicroCT, 4D-MicroCT, and MicroSPECT Imaging After Partial Heart Irradiation

    SciTech Connect

    Lee, Chang-Lung; Min, Hooney; Befera, Nicholas; Clark, Darin; Qi, Yi; Das, Shiva; Johnson, G. Allan; Badea, Cristian T.; Kirsch, David G.

    2014-03-01

    Purpose: To develop a mouse model of cardiac injury after partial heart irradiation (PHI) and to test whether dual energy (DE)-microCT and 4-dimensional (4D)-microCT can be used to assess cardiac injury after PHI to complement myocardial perfusion imaging using micro-single photon emission computed tomography (SPECT). Methods and Materials: To study cardiac injury from tangent field irradiation in mice, we used a small-field biological irradiator to deliver a single dose of 12 Gy x-rays to approximately one-third of the left ventricle (LV) of Tie2Cre; p53{sup FL/+} and Tie2Cre; p53{sup FL/−} mice, where 1 or both alleles of p53 are deleted in endothelial cells. Four and 8 weeks after irradiation, mice were injected with gold and iodinated nanoparticle-based contrast agents, and imaged with DE-microCT and 4D-microCT to evaluate myocardial vascular permeability and cardiac function, respectively. Additionally, the same mice were imaged with microSPECT to assess myocardial perfusion. Results: After PHI with tangent fields, DE-microCT scans showed a time-dependent increase in accumulation of gold nanoparticles (AuNp) in the myocardium of Tie2Cre; p53{sup FL/−} mice. In Tie2Cre; p53{sup FL/−} mice, extravasation of AuNp was observed within the irradiated LV, whereas in the myocardium of Tie2Cre; p53{sup FL/+} mice, AuNp were restricted to blood vessels. In addition, data from DE-microCT and microSPECT showed a linear correlation (R{sup 2} = 0.97) between the fraction of the LV that accumulated AuNp and the fraction of LV with a perfusion defect. Furthermore, 4D-microCT scans demonstrated that PHI caused a markedly decreased ejection fraction, and higher end-diastolic and end-systolic volumes, to develop in Tie2Cre; p53{sup FL/−} mice, which were associated with compensatory cardiac hypertrophy of the heart that was not irradiated. Conclusions: Our results show that DE-microCT and 4D-microCT with nanoparticle-based contrast agents are novel imaging approaches

  9. A Methodology to Detect Abnormal Relative Wall Shear Stress on the Full Surface of the Thoracic Aorta Using 4D Flow MRI

    PubMed Central

    van Ooij, Pim; Potters, Wouter V.; Nederveen, Aart J.; Allen, Bradley D.; Collins, Jeremy; Carr, James; Malaisrie, S. Chris; Markl, Michael; Barker, Alex J.

    2014-01-01

    Purpose To compute cohort-averaged wall shear stress (WSS) maps in the thoracic aorta of patients with aortic dilatation or valvular stenosis and to detect abnormal regional WSS. Methods Systolic WSS vectors, estimated from 4D flow MRI data, were calculated along the thoracic aorta lumen in 10 controls, 10 patients with dilated aortas and 10 patients with aortic valve stenosis. 3D segmentations of each aorta were co-registered by group and used to create a cohort-specific aortic geometry. The WSS vectors of each subject were interpolated onto the corresponding cohort-specific geometry to create cohort-averaged WSS maps. A Wilcoxon rank sum test was used to generate aortic P-value maps (P<0.05) representing regional relative WSS differences between groups. Results Cohort-averaged systolic WSS maps and P-value maps were successfully created for all cohorts and comparisons. The dilation cohort showed significantly lower WSS on 7% of the ascending aorta surface, whereas the stenosis cohort showed significantly higher WSS aorta on 34% the ascending aorta surface. Conclusions The findings of this study demonstrated the feasibility of generating cohort-averaged WSS maps for the visualization and identification of regionally altered WSS in the presence of disease, as compared to healthy controls. PMID:24753241

  10. The development of a population of 4D pediatric XCAT phantoms for CT imaging research and optimization

    NASA Astrophysics Data System (ADS)

    Norris, Hannah; Zhang, Yakun; Frush, Jack; Sturgeon, Gregory M.; Minhas, Anum; Tward, Daniel J.; Ratnanather, J. Tilak; Miller, M. I.; Frush, Donald; Samei, Ehsan; Segars, W. Paul

    2014-03-01

    With the increased use of CT examinations, the associated radiation dose has become a large concern, especially for pediatrics. Much research has focused on reducing radiation dose through new scanning and reconstruction methods. Computational phantoms provide an effective and efficient means for evaluating image quality, patient-specific dose, and organ-specific dose in CT. We previously developed a set of highly-detailed 4D reference pediatric XCAT phantoms at ages of newborn, 1, 5, 10, and 15 years with organ and tissues masses matched to ICRP Publication 89 values. We now extend this reference set to a series of 64 pediatric phantoms of a variety of ages and height and weight percentiles, representative of the public at large. High resolution PET-CT data was reviewed by a practicing experienced radiologist for anatomic regularity and was then segmented with manual and semi-automatic methods to form a target model. A Multi-Channel Large Deformation Diffeomorphic Metric Mapping (MC-LDDMM) algorithm was used to calculate the transform from the best age matching pediatric reference phantom to the patient target. The transform was used to complete the target, filling in the non-segmented structures and defining models for the cardiac and respiratory motions. The complete phantoms, consisting of thousands of structures, were then manually inspected for anatomical accuracy. 3D CT data was simulated from the phantoms to demonstrate their ability to generate realistic, patient quality imaging data. The population of pediatric phantoms developed in this work provides a vital tool to investigate dose reduction techniques in 3D and 4D pediatric CT.

  11. A registration based approach for 4D cardiac micro-CT using combined prospective and retrospective gating

    PubMed Central

    Badea, Cristian T.; Schreibmann, Eduard; Fox, Tim

    2008-01-01

    Recent advances in murine cardiac studies with three-dimensional cone beam micro-computed tomography (CT) have used either prospective or retrospective gating technique. While prospective gating ensures the best image quality and the highest resolution, it involves longer sampling times and higher radiation dose. Sampling is faster and the radiation dose can be reduced with retrospective gating but the image quality is affected by the limited number of projections with an irregular angular distribution which complicate the reconstruction process, causing significant streaking artifacts. This work involves both prospective and retrospective gating in sampling. Deformable registration is used between a high quality image set acquired with prospective gating with the multiple data sets during the cardiac cycle obtained using retrospective gating. Tests were conducted on a four-dimensional (4D) cardiac mouse phantom and after optimization, the method was applied to in vivo cardiac micro-CT data. Results indicate that, by using our method, the sampling time can be reduced by a factor of 2.5 and the radiation dose can be reduced 35% compared to the prospective sampling while the image quality can be maintained. In conclusion, we proposed a novel solution to 4D cine cardiac micro-CT based on a combined prospective with retrospective gating in sampling and deformable registration post reconstruction that mixed the advantages of both strategies. PMID:18491508

  12. 4D cone beam CT phase sorting using high frequency optical surface measurement during image guided radiotherapy

    NASA Astrophysics Data System (ADS)

    Price, G. J.; Marchant, T. E.; Parkhurst, J. M.; Sharrock, P. J.; Whitfield, G. A.; Moore, C. J.

    2011-03-01

    In image guided radiotherapy (IGRT) two of the most promising recent developments are four dimensional cone beam CT (4D CBCT) and dynamic optical metrology of patient surfaces. 4D CBCT is now becoming commercially available and finds use in treatment planning and verification, and whilst optical monitoring is a young technology, its ability to measure during treatment delivery without dose consequences has led to its uptake in many institutes. In this paper, we demonstrate the use of dynamic patient surfaces, simultaneously captured during CBCT acquisition using an optical sensor, to phase sort projection images for 4D CBCT volume reconstruction. The dual modality approach we describe means that in addition to 4D volumetric data, the system provides correlated wide field measurements of the patient's skin surface with high spatial and temporal resolution. As well as the value of such complementary data in verification and motion analysis studies, it introduces flexibility into the acquisition of the signal required for phase sorting. The specific technique used may be varied according to individual patient circumstances and the imaging target. We give details of three different methods of obtaining a suitable signal from the optical surfaces: simply following the motion of triangulation spots used to calibrate the surfaces' absolute height; monitoring the surface height in a single, arbitrarily selected, camera pixel; and tracking, in three dimensions, the movement of a surface feature. In addition to describing the system and methodology, we present initial results from a case study oesophageal cancer patient.

  13. Effect of CAD on radiologists' detection of lung nodules on thoracic CT scans: observer performance study

    NASA Astrophysics Data System (ADS)

    Sahiner, Berkman; Hadjiiski, Lubomir M.; Chan, Heang-Ping; Shi, Jiazheng; Cascade, Philip N.; Kazerooni, Ella A.; Zhou, Chuan; Wei, Jun; Chughtai, Aamer R.; Poopat, Chad; Song, Thomas; Nojkova, Jadranka S.; Frank, Luba; Attili, Anil

    2007-03-01

    The purpose of this study was to evaluate the effect of computer-aided diagnosis (CAD) on radiologists' performance for the detection of lung nodules on thoracic CT scans. Our computer system was designed using an independent training set of 94 CT scans in our laboratory. The data set for the observer performance study consisted of 48 CT scans. Twenty scans were collected from patient files at the University of Michigan, and 28 scans by the Lung Imaging Database Consortium (LIDC). All scans were read by multiple experienced thoracic radiologists to determine the true nodule locations, defined as any region identified by one or more expert radiologists as containing a nodule larger than 3 mm in diameter. Eighteen CT examinations were nodule-free, while the remaining 30 CT examinations contained a total of 73 nodules having a median size of 5.5 mm (range 3.0-36.4 mm). Four other study radiologists read the CT scans first without and then with CAD, and provided likelihood of nodule ratings for suspicious regions. Two of the study radiologists were fellowship trained in cardiothoracic radiology, and two were cardiothoracic radiology fellows. Freeresponse receiver-operating characteristic (FROC) curves were used to compare the two reading conditions. The computer system had a sensitivity of 79% (58/73) with an average of 4.9 marks per normal scan (88/18). Jackknife alternative FROC (JAFROC) analysis indicated that the improvement with CAD was statistically significant (p=0.03).

  14. From 3D to 4D: Integration of temporal information into CT angiography studies.

    PubMed

    Haubenreisser, Holger; Bigdeli, Amir; Meyer, Mathias; Kremer, Thomas; Riester, Thomas; Kneser, Ulrich; Schoenberg, Stefan O; Henzler, Thomas

    2015-12-01

    CT angiography is the current clinical standard for the imaging many vascular illnesses. This is traditionally done with a single arterial contrast phase. However, advances in CT technology allow for a dynamic acquisition of the contrast bolus, thus adding temporal information to the examination. The aim of this article is to highlight the clinical possibilities of dynamic CTA using 2 examples. The accuracy of the detection and quantification of stenosis in patients with peripheral arterial occlusive disease, especially in stadium III and IV, is significantly improved when performing dynamic CTA examinations. The post-interventional follow-up of examinations of EVAR benefit from dynamic information, allowing for a higher sensitivity and specificity, as well as allowing more accurate classification of potential endoleaks. The described radiation dose for these dynamic examinations is low, but this can be further optimized by using lower tube voltages. There are a multitude of applications for dynamic CTA that need to be further explored in future studies.

  15. Limits of normality of quantitative thoracic CT analysis

    PubMed Central

    2013-01-01

    Introduction Although computed tomography (CT) is widely used to investigate different pathologies, quantitative data from normal populations are scarce. Reference values may be useful to estimate the anatomical or physiological changes induced by various diseases. Methods We analyzed 100 helical CT scans taken for clinical purposes and referred as nonpathological by the radiologist. Profiles were manually outlined on each CT scan slice and each voxel was classified according to its gas/tissue ratio. For regional analysis, the lungs were divided into 10 sterno-vertebral levels. Results We studied 53 males and 47 females (age 64 ± 13 years); males had a greater total lung volume, lung gas volume and lung tissue. Noninflated tissue averaged 7 ± 4% of the total lung weight, poorly inflated tissue averaged 18 ± 3%, normally inflated tissue averaged 65 ± 8% and overinflated tissue averaged 11 ± 7%. We found a significant correlation between lung weight and subject's height (P <0.0001, r2 = 0.49); the total lung capacity in a supine position was 4,066 ± 1,190 ml, ~1,800 ml less than the predicted total lung capacity in a sitting position. Superimposed pressure averaged 2.6 ± 0.5 cmH2O. Conclusion Subjects without lung disease present significant amounts of poorly inflated and overinflated tissue. Normal lung weight can be predicted from patient's height with reasonable confidence. PMID:23706034

  16. Thoracic Cavity Definition for 3D PET/CT Analysis and Visualization

    PubMed Central

    Cheirsilp, Ronnarit; Bascom, Rebecca; Allen, Thomas W.; Higgins, William E.

    2015-01-01

    X-ray computed tomography (CT) and positron emission tomography (PET) serve as the standard imaging modalities for lung-cancer management. CT gives anatomical detail on diagnostic regions of interest (ROIs), while PET gives highly specific functional information. During the lung-cancer management process, a patient receives a co-registered whole-body PET/CT scan pair and a dedicated high-resolution chest CT scan. With these data, multimodal PET/CT ROI information can be gleaned to facilitate disease management. Effective image segmentation of the thoracic cavity, however, is needed to focus attention on the central chest. We present an automatic method for thoracic cavity segmentation from 3D CT scans. We then demonstrate how the method facilitates 3D ROI localization and visualization in patient multimodal imaging studies. Our segmentation method draws upon digital topological and morphological operations, active-contour analysis, and key organ landmarks. Using a large patient database, the method showed high agreement to ground-truth regions, with a mean coverage = 99.2% and leakage = 0.52%. Furthermore, it enabled extremely fast computation. For PET/CT lesion analysis, the segmentation method reduced ROI search space by 97.7% for a whole-body scan, or nearly 3 times greater than that achieved by a lung mask. Despite this reduction, we achieved 100% true-positive ROI detection, while also reducing the false-positive (FP) detection rate by >5 times over that achieved with a lung mask. Finally, the method greatly improved PET/CT visualization by eliminating false PET-avid obscurations arising from the heart, bones, and liver. In particular, PET MIP views and fused PET/CT renderings depicted unprecedented clarity of the lesions and neighboring anatomical structures truly relevant to lung-cancer assessment. PMID:25957746

  17. TIPS bilateral noise reduction in 4D CT perfusion scans produces high-quality cerebral blood flow maps

    NASA Astrophysics Data System (ADS)

    Mendrik, Adriënne M.; Vonken, Evert-jan; van Ginneken, Bram; de Jong, Hugo W.; Riordan, Alan; van Seeters, Tom; Smit, Ewoud J.; Viergever, Max A.; Prokop, Mathias

    2011-07-01

    Cerebral computed tomography perfusion (CTP) scans are acquired to detect areas of abnormal perfusion in patients with cerebrovascular diseases. These 4D CTP scans consist of multiple sequential 3D CT scans over time. Therefore, to reduce radiation exposure to the patient, the amount of x-ray radiation that can be used per sequential scan is limited, which results in a high level of noise. To detect areas of abnormal perfusion, perfusion parameters are derived from the CTP data, such as the cerebral blood flow (CBF). Algorithms to determine perfusion parameters, especially singular value decomposition, are very sensitive to noise. Therefore, noise reduction is an important preprocessing step for CTP analysis. In this paper, we propose a time-intensity profile similarity (TIPS) bilateral filter to reduce noise in 4D CTP scans, while preserving the time-intensity profiles (fourth dimension) that are essential for determining the perfusion parameters. The proposed TIPS bilateral filter is compared to standard Gaussian filtering, and 4D and 3D (applied separately to each sequential scan) bilateral filtering on both phantom and patient data. Results on the phantom data show that the TIPS bilateral filter is best able to approach the ground truth (noise-free phantom), compared to the other filtering methods (lowest root mean square error). An observer study is performed using CBF maps derived from fifteen CTP scans of acute stroke patients filtered with standard Gaussian, 3D, 4D and TIPS bilateral filtering. These CBF maps were blindly presented to two observers that indicated which map they preferred for (1) gray/white matter differentiation, (2) detectability of infarcted area and (3) overall image quality. Based on these results, the TIPS bilateral filter ranked best and its CBF maps were scored to have the best overall image quality in 100% of the cases by both observers. Furthermore, quantitative CBF and cerebral blood volume values in both the phantom and the

  18. Haptic Landmark Positioning and Automatic Landmark Transfer in 4D Lung CT Data

    NASA Astrophysics Data System (ADS)

    Färber, Matthias; Gawenda, Björn; Bohn, Christian-Arved; Handels, Heinz

    Manual landmark positioning in volumetric image data is a complex task and often results in erroneous landmark positions. The landmark positioning tool presented uses image curvature features to precompute suitable candidates for landmark positions on surface data of anatomical structures. A force-feedback I/O device is then used to haptically guide the user during the definition of the correct landmarks in the 3D data volume. Furthermore, existing landmarks in a time-point of a sequence of 3D volumes (4D data set) can iteratively be transferred to other time-points using a surface based registration technique. First results show significant time savings and small interobserver variability (IROV) compared to the IROV of manually defined landmark positions using orthogonal slices of the image data.

  19. Semi-automatic classification of textures in thoracic CT scans

    NASA Astrophysics Data System (ADS)

    Kockelkorn, Thessa T. J. P.; de Jong, Pim A.; Schaefer-Prokop, Cornelia M.; Wittenberg, Rianne; Tiehuis, Audrey M.; Gietema, Hester A.; Grutters, Jan C.; Viergever, Max A.; van Ginneken, Bram

    2016-08-01

    The textural patterns in the lung parenchyma, as visible on computed tomography (CT) scans, are essential to make a correct diagnosis in interstitial lung disease. We developed one automatic and two interactive protocols for classification of normal and seven types of abnormal lung textures. Lungs were segmented and subdivided into volumes of interest (VOIs) with homogeneous texture using a clustering approach. In the automatic protocol, VOIs were classified automatically by an extra-trees classifier that was trained using annotations of VOIs from other CT scans. In the interactive protocols, an observer iteratively trained an extra-trees classifier to distinguish the different textures, by correcting mistakes the classifier makes in a slice-by-slice manner. The difference between the two interactive methods was whether or not training data from previously annotated scans was used in classification of the first slice. The protocols were compared in terms of the percentages of VOIs that observers needed to relabel. Validation experiments were carried out using software that simulated observer behavior. In the automatic classification protocol, observers needed to relabel on average 58% of the VOIs. During interactive annotation without the use of previous training data, the average percentage of relabeled VOIs decreased from 64% for the first slice to 13% for the second half of the scan. Overall, 21% of the VOIs were relabeled. When previous training data was available, the average overall percentage of VOIs requiring relabeling was 20%, decreasing from 56% in the first slice to 13% in the second half of the scan.

  20. Computational biomechanics and experimental validation of vessel deformation based on 4D-CT imaging of the porcine aorta

    NASA Astrophysics Data System (ADS)

    Hazer, Dilana; Finol, Ender A.; Kostrzewa, Michael; Kopaigorenko, Maria; Richter, Götz-M.; Dillmann, Rüdiger

    2009-02-01

    Cardiovascular disease results from pathological biomechanical conditions and fatigue of the vessel wall. Image-based computational modeling provides a physical and realistic insight into the patient-specific biomechanics and enables accurate predictive simulations of development, growth and failure of cardiovascular disease. An experimental validation is necessary for the evaluation and the clinical implementation of such computational models. In the present study, we have implemented dynamic Computed-Tomography (4D-CT) imaging and catheter-based in vivo measured pressures to numerically simulate and experimentally evaluate the biomechanics of the porcine aorta. The computations are based on the Finite Element Method (FEM) and simulate the arterial wall response to the transient pressure-based boundary condition. They are evaluated by comparing the numerically predicted wall deformation and that calculated from the acquired 4D-CT data. The dynamic motion of the vessel is quantified by means of the hydraulic diameter, analyzing sequences at 5% increments over the cardiac cycle. Our results show that accurate biomechanical modeling is possible using FEM-based simulations. The RMS error of the computed hydraulic diameter at five cross-sections of the aorta was 0.188, 0.252, 0.280, 0.237 and 0.204 mm, which is equivalent to 1.7%, 2.3%, 2.7%, 2.3% and 2.0%, respectively, when expressed as a function of the time-averaged hydraulic diameter measured from the CT images. The present investigation is a first attempt to simulate and validate vessel deformation based on realistic morphological data and boundary conditions. An experimentally validated system would help in evaluating individual therapies and optimal treatment strategies in the field of minimally invasive endovascular surgery.

  1. Dynamic Multiscale Boundary Conditions for 4D CT Images of Healthy and Emphysematous Rat

    SciTech Connect

    Jacob, Rick E.; Carson, James P.; Thomas, Mathew; Einstein, Daniel R.

    2013-06-14

    Changes in the shape of the lung during breathing determine the movement of airways and alveoli, and thus impact airflow dynamics. Modeling airflow dynamics in health and disease is a key goal for predictive multiscale models of respiration. Past efforts to model changes in lung shape during breathing have measured shape at multiple breath-holds. However, breath-holds do not capture hysteretic differences between inspiration and expiration resulting from the additional energy required for inspiration. Alternatively, imaging dynamically – without breath-holds – allows measurement of hysteretic differences. In this study, we acquire multiple micro-CT images per breath (4DCT) in live rats, and from these images we develop, for the first time, dynamic volume maps. These maps show changes in local volume across the entire lung throughout the breathing cycle and accurately predict the global pressure-volume (PV) hysteresis.

  2. Respiratory motion variations from skin surface on lung cancer patients from 4D CT data

    NASA Astrophysics Data System (ADS)

    Gallego-Ortiz, Nicolas; Orban de Xivry, Jonathan; Descampe, Antonin; Goossens, Samuel; Geets, Xavier; Janssens, Guillaume; Macq, Benoit

    2014-03-01

    In radiation therapy of thorax and abdomen regions, knowing how respiratory motion modifies tumor position and trajectory is crucial for accurate dose delivery to tumors while avoiding healthy tissue and organs at risk. Three types of variations are studied: motion amplitudes measured from the patient's skin surface and internal tumor trajectory, internal/external correlations and tumor trajectory baseline shift. Four male patients with lung cancer with three repeated 4D computed tomography (4DCT) scans, taken on different treatment days, were studied. Surfaces were extracted from 4DCT scans by segmentation. Motion over specific regions of interest was analyzed with respect to the motion of the tumor center of mass and correlation coefficient was computed. Tumor baseline shifts were analyzed after rigid registration based on vertebrae and surface registration. External amplitude variations were observed between fractions. Correlation coefficients of internal trajectories and external distances are greater than 0.6 in the abdomen. This correlation was observable and significant for all patients showing that the external motion is a good surrogate for internal movement on an intra-fraction basis. However for the inter-fraction case, external amplitude variations were observed between fractions and no correlation was found with the internal amplitude variations. Moreover, baseline shifts after surface registration were greater than those after vertebrae registration and the mean distance between surfaces after registration was not correlated to the magnitude of the baseline shift. These two observations show that, with the current representation of the external surface, inter-fraction variations are not detectable on the surface.

  3. Evaluation of Fractional Regional Ventilation Using 4D-CT and Effects of Breathing Maneuvers on Ventilation

    SciTech Connect

    Mistry, Nilesh N.; Diwanji, Tejan; Shi, Xiutao; Pokharel, Sabin; Feigenberg, Steven; Scharf, Steven M.; D'Souza, Warren D.

    2013-11-15

    Purpose: Current implementations of methods based on Hounsfield units to evaluate regional lung ventilation do not directly incorporate tissue-based mass changes that occur over the respiratory cycle. To overcome this, we developed a 4-dimensional computed tomography (4D-CT)-based technique to evaluate fractional regional ventilation (FRV) that uses an individualized ratio of tidal volume to end-expiratory lung volume for each voxel. We further evaluated the effect of different breathing maneuvers on regional ventilation. The results from this work will help elucidate the relationship between global and regional lung function. Methods and Materials: Eight patients underwent 3 sets of 4D-CT scans during 1 session using free-breathing, audiovisual guidance, and active breathing control. FRV was estimated using a density-based algorithm with mass correction. Internal validation between global and regional ventilation was performed by use of the imaging data collected during the use of active breathing control. The impact of breathing maneuvers on FRV was evaluated comparing the tidal volume from 3 breathing methods. Results: Internal validation through comparison between the global and regional changes in ventilation revealed a strong linear correlation (slope of 1.01, R{sup 2} of 0.97) between the measured global lung volume and the regional lung volume calculated by use of the “mass corrected” FRV. A linear relationship was established between the tidal volume measured with the automated breathing control system and FRV based on 4D-CT imaging. Consistently larger breathing volumes were observed when coached breathing techniques were used. Conclusions: The technique presented improves density-based evaluation of lung ventilation and establishes a link between global and regional lung ventilation volumes. Furthermore, the results obtained are comparable with those of other techniques of functional evaluation such as spirometry and hyperpolarized-gas magnetic

  4. SU-E-J-153: Reconstructing 4D Cone Beam CT Images for Clinical QA of Lung SABR Treatments

    SciTech Connect

    Beaudry, J; Bergman, A; Cropp, R

    2015-06-15

    Purpose: To verify that the planned Primary Target Volume (PTV) and Internal Gross Tumor Volume (IGTV) fully enclose a moving lung tumor volume as visualized on a pre-SABR treatment verification 4D Cone Beam CT. Methods: Daily 3DCBCT image sets were acquired immediately prior to treatment for 10 SABR lung patients using the on-board imaging system integrated into a Varian TrueBeam (v1.6: no 4DCBCT module available). Respiratory information was acquired during the scan using the Varian RPM system. The CBCT projections were sorted into 8 bins offline, both by breathing phase and amplitude, using in-house software. An iterative algorithm based on total variation minimization, implemented in the open source reconstruction toolkit (RTK), was used to reconstruct the binned projections into 4DCBCT images. The relative tumor motion was quantified by tracking the centroid of the tumor volume from each 4DCBCT image. Following CT-CBCT registration, the planning CT volumes were compared to the location of the CBCT tumor volume as it moves along its breathing trajectory. An overlap metric quantified the ability of the planned PTV and IGTV to contain the tumor volume at treatment. Results: The 4DCBCT reconstructed images visibly show the tumor motion. The mean overlap between the planned PTV (IGTV) and the 4DCBCT tumor volumes was 100% (94%), with an uncertainty of 5% from the 4DCBCT tumor volume contours. Examination of the tumor motion and overlap metric verify that the IGTV drawn at the planning stage is a good representation of the tumor location at treatment. Conclusion: It is difficult to compare GTV volumes from a 4DCBCT and a planning CT due to image quality differences. However, it was possible to conclude the GTV remained within the PTV 100% of the time thus giving the treatment staff confidence that SABR lung treatements are being delivered accurately.

  5. Dynamic Multiscale Boundary Conditions for 4D CT of Healthy and Emphysematous Rats

    PubMed Central

    Jacob, Richard E.; Carson, James P.; Thomas, Mathew; Einstein, Daniel R.

    2013-01-01

    Changes in the shape of the lung during breathing determine the movement of airways and alveoli, and thus impact airflow dynamics. Modeling airflow dynamics in health and disease is a key goal for predictive multiscale models of respiration. Past efforts to model changes in lung shape during breathing have measured shape at multiple breath-holds. However, breath-holds do not capture hysteretic differences between inspiration and expiration resulting from the additional energy required for inspiration. Alternatively, imaging dynamically – without breath-holds – allows measurement of hysteretic differences. In this study, we acquire multiple micro-CT images per breath (4DCT) in live rats, and from these images we develop, for the first time, dynamic volume maps. These maps show changes in local volume across the entire lung throughout the breathing cycle and accurately predict the global pressure-volume (PV) hysteresis. Male Sprague-Dawley rats were given either a full- or partial-lung dose of elastase or saline as a control. After three weeks, 4DCT images of the mechanically ventilated rats under anesthesia were acquired dynamically over the breathing cycle (11 time points, ≤100 ms temporal resolution, 8 cmH2O peak pressure). Non-rigid image registration was applied to determine the deformation gradient – a numerical description of changes to lung shape – at each time point. The registration accuracy was evaluated by landmark identification. Of 67 landmarks, one was determined misregistered by all three observers, and 11 were determined misregistered by two observers. Volume change maps were calculated on a voxel-by-voxel basis at all time points using both the Jacobian of the deformation gradient and the inhaled air fraction. The calculated lung PV hysteresis agrees with pressure-volume curves measured by the ventilator. Volume maps in diseased rats show increased compliance and ventilation heterogeneity. Future predictive multiscale models of rodent

  6. Economic impact of real-time teleradiology in thoracic CT examinations.

    PubMed

    Takada, Akihiro; Kasahara, Toshiyuki; Kinosada, Yasutomi; Hosoba, Minoru; Nishimura, Tsunehiko

    2003-07-01

    Conventional teleradiology is a useful tool, but sometimes we have found it to be an insufficient means of investigation because the radiological specialists cannot indicate the imaging protocol during the investigation. The purpose of our study was to evaluate the efficacy of real-time teleradiology, which will improve the quality of medical management. Ten radiologists evaluated thoracic CT scans of 50 patients transmitted through teleradiology retrospectively. We evaluated whether or not the contrast enhancement study was performed effectively on the basis of the clinical data and after interpretation of the pre-contrast scans. The clinical data showed that 47.6% of the CT contrast enhancement examinations were not necessary. After interpretation of the pre-contrast CT scans, 66.6% of the contrast-enhanced scans were considered unnecessary. Real-time teleradiology will improve the quality of medical management providing the virtual presence of radiologists, and will save medical costs.

  7. Automated pulmonary lobar ventilation measurements using volume-matched thoracic CT and MRI

    NASA Astrophysics Data System (ADS)

    Guo, F.; Svenningsen, S.; Bluemke, E.; Rajchl, M.; Yuan, J.; Fenster, A.; Parraga, G.

    2015-03-01

    Objectives: To develop and evaluate an automated registration and segmentation pipeline for regional lobar pulmonary structure-function measurements, using volume-matched thoracic CT and MRI in order to guide therapy. Methods: Ten subjects underwent pulmonary function tests and volume-matched 1H and 3He MRI and thoracic CT during a single 2-hr visit. CT was registered to 1H MRI using an affine method that incorporated block-matching and this was followed by a deformable step using free-form deformation. The resultant deformation field was used to deform the associated CT lobe mask that was generated using commercial software. 3He-1H image registration used the same two-step registration method and 3He ventilation was segmented using hierarchical k-means clustering. Whole lung and lobar 3He ventilation and ventilation defect percent (VDP) were generated by mapping ventilation defects to CT-defined whole lung and lobe volumes. Target CT-3He registration accuracy was evaluated using region- , surface distance- and volume-based metrics. Automated whole lung and lobar VDP was compared with semi-automated and manual results using paired t-tests. Results: The proposed pipeline yielded regional spatial agreement of 88.0+/-0.9% and surface distance error of 3.9+/-0.5 mm. Automated and manual whole lung and lobar ventilation and VDP were not significantly different and they were significantly correlated (r = 0.77, p < 0.0001). Conclusion: The proposed automated pipeline can be used to generate regional pulmonary structural-functional maps with high accuracy and robustness, providing an important tool for image-guided pulmonary interventions.

  8. Validating and improving CT ventilation imaging by correlating with ventilation 4D-PET/CT using {sup 68}Ga-labeled nanoparticles

    SciTech Connect

    Kipritidis, John Keall, Paul J.; Siva, Shankar; Hofman, Michael S.; Callahan, Jason; Hicks, Rodney J.

    2014-01-15

    Purpose: CT ventilation imaging is a novel functional lung imaging modality based on deformable image registration. The authors present the first validation study of CT ventilation using positron emission tomography with{sup 68}Ga-labeled nanoparticles (PET-Galligas). The authors quantify this agreement for different CT ventilation metrics and PET reconstruction parameters. Methods: PET-Galligas ventilation scans were acquired for 12 lung cancer patients using a four-dimensional (4D) PET/CT scanner. CT ventilation images were then produced by applying B-spline deformable image registration between the respiratory correlated phases of the 4D-CT. The authors test four ventilation metrics, two existing and two modified. The two existing metrics model mechanical ventilation (alveolar air-flow) based on Hounsfield unit (HU) change (V{sub HU}) or Jacobian determinant of deformation (V{sub Jac}). The two modified metrics incorporate a voxel-wise tissue-density scaling (ρV{sub HU} and ρV{sub Jac}) and were hypothesized to better model the physiological ventilation. In order to assess the impact of PET image quality, comparisons were performed using both standard and respiratory-gated PET images with the former exhibiting better signal. Different median filtering kernels (σ{sub m} = 0 or 3 mm) were also applied to all images. As in previous studies, similarity metrics included the Spearman correlation coefficient r within the segmented lung volumes, and Dice coefficient d{sub 20} for the (0 − 20)th functional percentile volumes. Results: The best agreement between CT and PET ventilation was obtained comparing standard PET images to the density-scaled HU metric (ρV{sub HU}) with σ{sub m} = 3 mm. This leads to correlation values in the ranges 0.22 ⩽ r ⩽ 0.76 and 0.38 ⩽ d{sub 20} ⩽ 0.68, with r{sup ¯}=0.42±0.16 and d{sup ¯}{sub 20}=0.52±0.09 averaged over the 12 patients. Compared to Jacobian-based metrics, HU-based metrics lead to statistically significant

  9. Towards a comprehensive CT image segmentation for thoracic organ radiation dose estimation and reporting

    NASA Astrophysics Data System (ADS)

    Lorenz, Cristian; Ruppertshofen, Heike; Vik, Torbjörn; Prinsen, Peter; Wiegert, Jens

    2014-03-01

    Administered dose of ionizing radiation during medical imaging is an issue of increasing concern for the patient, for the clinical community, and for respective regulatory bodies. CT radiation dose is currently estimated based on a set of very simplifying assumptions which do not take the actual body geometry and organ specific doses into account. This makes it very difficult to accurately report imaging related administered dose and to track it for different organs over the life of the patient. In this paper this deficit is addressed in a two-fold way. In a first step, the absorbed radiation dose in each image voxel is estimated based on a Monte-Carlo simulation of X-ray absorption and scattering. In a second step, the image is segmented into tissue types with different radio sensitivity. In combination this allows to calculate the effective dose as a weighted sum of the individual organ doses. The main purpose of this paper is to assess the feasibility of automatic organ specific dose estimation. With respect to a commercially applicable solution and respective robustness and efficiency requirements, we investigated the effect of dose sampling rather than integration over the organ volume. We focused on the thoracic anatomy as the exemplary body region, imaged frequently by CT. For image segmentation we applied a set of available approaches which allowed us to cover the main thoracic radio-sensitive tissue types. We applied the dose estimation approach to 10 thoracic CT datasets and evaluated segmentation accuracy and administered dose and could show that organ specific dose estimation can be achieved.

  10. Thoracic CT

    MedlinePlus

    ... your kidneys are healthy enough to filter the contrast. ... Some people have allergies to IV contrast and may need to take medications before their test to safely receive this substance. Contrast can be given in ...

  11. Alignment of full and partial CT thoracic scans using bony structures

    NASA Astrophysics Data System (ADS)

    Gavrielides, Marios A.; Petrick, Nicholas; Myers, Kyle J.

    2006-03-01

    Diagnostic thoracic procedures using computed tomography (CT) often include comparisons of scans acquired with different slice thicknesses. In this manuscript, we investigated the potential for alignment of different CT scans from the same patient using skeletal knowledge of the thoracic region. Skeletal matching was selected because it is expected to be less susceptible to differences associated with patient breath hold, positioning and cardiac motion. Our method utilized the positioning of the ribs relative to the vertebra for matching. It also included matching the scapula when visible in the scans. Rib positioning was described by the angles formed between the vertebra centroid and combinations of pairs of rib centroids visible on each CT slice; this was used as the primary matching mechanism. Scapula morphology was described using a feature based on the local maxima of the distance transform. Since the scapula is not visible in all slices of a full scan, its description was limited to only defining the potential range of slices. A cost function incorporating the difference of features from rib positioning and scapula morphology between two slices was derived and used to match slices. The method was evaluated on an independent set of 10 pairs of full and partial CT scans. Assessment was based on whether or not slices containing known nodules between each pair of scans were overlapping after the alignment procedure. Results showed that the proposed metric correctly aligned 9 out of 10 scans. The preliminary results are encouraging for using this method as a first step towards temporal analysis of lung nodules.

  12. SU-E-J-207: Assessing the Validity of 4D-CT Based Target Volumes and Free Breathing CBCT Localization in Lung Stereotactic Ablative Radiation Therapy (SABR)

    SciTech Connect

    Badkul, R; Pokhrel, D; Jiang, H; Park, J; Wang, F; Kumar, P

    2014-06-01

    Purpose: Four-dimensional-computed-tomography(4D-CT) imaging for target-volume delineation and cone-beam-tomography(CBCT) for treatment localization are widely utilized in lung-SABR.Aim of this study was to perform a quantitative-assessment and inter-comparison of Internal-targetvolumes( ITV) drawn on various phases of breathing-cycle 4D-CT-scans, Maximum-intensity-projection(MIP), average-intensity-projection(AIP)and static CT-scans of lung-motion-phantom to simulate lung-SABR patient geometry. We also analyzed and compared the ITVs drawn on freebreathing- CBCT. Materials and Methods: 4D-CT-scans were acquired on Philips big-bore 16slice CT and Bellows-respiratory monitoring-system using retrospective phase-binning method. Each respiratory cycle divided into 10-phases. Quasar-Phantom with lung-inserts and 3cm-diameter nylonball to simulate tumor and was placed on respiratory-motion-platform for 4D-CT and CBCT-acquisition. Amplitudes of motions: 0.5,1.0,2.0,3.0cm in superior-inferior direction with breathing-cycle time of 6,5,4,6sec, respectively used.4D-CTs with 10-phases(0%to90%)for each excursion-set and 3D-CT for static-phantom exported to iPlan treatment-planningsystem( TPS).Tumor-volumes delineated in all phases of 4D-CT, MIP,AIP,CBCT scans using fixed-HU-threshold(−500to1000)values automatically.For each 4D-dataset ITV obtained by unifying the tumorcontours on all phases.CBCT-ITV-volumes were drawn in Eclipse-TPS. Results: Mean volume of tumor contours for all phases compared with static 3D-CT were 0.62±0.08%, 1.67±0.26%, 4.77±0.54% and 9.27±1.23% for 0.5cm,1cm,2cm,3cm excursions respectively. Differences of mean Union-ITV with MIP-ITV were close(≤2.4%).Mean Union-ITV from expected-theoretical values differed from −4.9% to 3.8%.Union-ITV and MIP-ITV were closer within 2.3%. AIP-ITVs were underestimated from 14 to 32% compared to union-ITV for all motion datasets. Differences of −5.9% to −44% and −5% to 6.7% for CBCT-ITV from MIP-ITV and AIP

  13. Classification of patterns for diffuse lung diseases in thoracic CT images by AdaBoost algorithm

    NASA Astrophysics Data System (ADS)

    Kuwahara, Masayuki; Kido, Shoji; Shouno, Hayaru

    2009-02-01

    CT images are considered as effective for differential diagnosis of diffuse lung diseases. However, the diagnosis of diffuse lung diseases is a difficult problem for the radiologists, because they show a variety of patterns on CT images. So, our purpose is to construct a computer-aided diagnosis (CAD) system for classification of patterns for diffuse lung diseases in thoracic CT images, which gives both quantitative and objective information as a second opinion, to decrease the burdens of radiologists. In this article, we propose a CAD system based on the conventional pattern recognition framework, which consists of two sub-systems; one is feature extraction part and the other is classification part. In the feature extraction part, we adopted a Gabor filter, which can extract patterns such like local edges and segments from input textures, as a feature extraction of CT images. In the recognition part, we used a boosting method. Boosting is a kind of voting method by several classifiers to improve decision precision. We applied AdaBoost algorithm for boosting method. At first, we evaluated each boosting component classifier, and we confirmed they had not enough performances in classification of patterns for diffuse lung diseases. Next, we evaluated the performance of boosting method. As a result, by use of our system, we could improve the classification rate of patterns for diffuse lung diseases.

  14. Estimation of the delivered patient dose in lung IMRT treatment based on deformable registration of 4D-CT data and Monte Carlo simulations

    NASA Astrophysics Data System (ADS)

    Flampouri, Stella; Jiang, Steve B.; Sharp, Greg C.; Wolfgang, John; Patel, Abhijit A.; Choi, Noah C.

    2006-06-01

    The purpose of this study is to accurately estimate the difference between the planned and the delivered dose due to respiratory motion and free breathing helical CT artefacts for lung IMRT treatments, and to estimate the impact of this difference on clinical outcome. Six patients with representative tumour motion, size and position were selected for this retrospective study. For each patient, we had acquired both a free breathing helical CT and a ten-phase 4D-CT scan. A commercial treatment planning system was used to create four IMRT plans for each patient. The first two plans were based on the GTV as contoured on the free breathing helical CT set, with a GTV to PTV expansion of 1.5 cm and 2.0 cm, respectively. The third plan was based on the ITV, a composite volume formed by the union of the CTV volumes contoured on free breathing helical CT, end-of-inhale (EOI) and end-of-exhale (EOE) 4D-CT. The fourth plan was based on GTV contoured on the EOE 4D-CT. The prescribed dose was 60 Gy for all four plans. Fluence maps and beam setup parameters of the IMRT plans were used by the Monte Carlo dose calculation engine MCSIM for absolute dose calculation on both the free breathing CT and 4D-CT data. CT deformable registration between the breathing phases was performed to estimate the motion trajectory for both the tumour and healthy tissue. Then, a composite dose distribution over the whole breathing cycle was calculated as a final estimate of the delivered dose. EUD values were computed on the basis of the composite dose for all four plans. For the patient with the largest motion effect, the difference in the EUD of CTV between the planed and the delivered doses was 33, 11, 1 and 0 Gy for the first, second, third and fourth plan, respectively. The number of breathing phases required for accurate dose prediction was also investigated. With the advent of 4D-CT, deformable registration and Monte Carlo simulations, it is feasible to perform an accurate calculation of the

  15. Estimation of the delivered patient dose in lung IMRT treatment based on deformable registration of 4D-CT data and Monte Carlo simulations.

    PubMed

    Flampouri, Stella; Jiang, Steve B; Sharp, Greg C; Wolfgang, John; Patel, Abhijit A; Choi, Noah C

    2006-06-01

    The purpose of this study is to accurately estimate the difference between the planned and the delivered dose due to respiratory motion and free breathing helical CT artefacts for lung IMRT treatments, and to estimate the impact of this difference on clinical outcome. Six patients with representative tumour motion, size and position were selected for this retrospective study. For each patient, we had acquired both a free breathing helical CT and a ten-phase 4D-CT scan. A commercial treatment planning system was used to create four IMRT plans for each patient. The first two plans were based on the GTV as contoured on the free breathing helical CT set, with a GTV to PTV expansion of 1.5 cm and 2.0 cm, respectively. The third plan was based on the ITV, a composite volume formed by the union of the CTV volumes contoured on free breathing helical CT, end-of-inhale (EOI) and end-of-exhale (EOE) 4D-CT. The fourth plan was based on GTV contoured on the EOE 4D-CT. The prescribed dose was 60 Gy for all four plans. Fluence maps and beam setup parameters of the IMRT plans were used by the Monte Carlo dose calculation engine MCSIM for absolute dose calculation on both the free breathing CT and 4D-CT data. CT deformable registration between the breathing phases was performed to estimate the motion trajectory for both the tumour and healthy tissue. Then, a composite dose distribution over the whole breathing cycle was calculated as a final estimate of the delivered dose. EUD values were computed on the basis of the composite dose for all four plans. For the patient with the largest motion effect, the difference in the EUD of CTV between the planed and the delivered doses was 33, 11, 1 and 0 Gy for the first, second, third and fourth plan, respectively. The number of breathing phases required for accurate dose prediction was also investigated. With the advent of 4D-CT, deformable registration and Monte Carlo simulations, it is feasible to perform an accurate calculation of the

  16. TH-E-17A-06: Anatomical-Adaptive Compressed Sensing (AACS) Reconstruction for Thoracic 4-Dimensional Cone-Beam CT

    SciTech Connect

    Shieh, C; Kipritidis, J; OBrien, R; Cooper, B; Kuncic, Z; Keall, P

    2014-06-15

    Purpose: The Feldkamp-Davis-Kress (FDK) algorithm currently used for clinical thoracic 4-dimensional (4D) cone-beam CT (CBCT) reconstruction suffers from noise and streaking artifacts due to projection under-sampling. Compressed sensing theory enables reconstruction of under-sampled datasets via total-variation (TV) minimization, but TV-minimization algorithms such as adaptive-steepest-descent-projection-onto-convex-sets (ASD-POCS) often converge slowly and are prone to over-smoothing anatomical details. These disadvantages can be overcome by incorporating general anatomical knowledge via anatomy segmentation. Based on this concept, we have developed an anatomical-adaptive compressed sensing (AACS) algorithm for thoracic 4D-CBCT reconstruction. Methods: AACS is based on the ASD-POCS framework, where each iteration consists of a TV-minimization step and a data fidelity constraint step. Prior to every AACS iteration, four major thoracic anatomical structures - soft tissue, lungs, bony anatomy, and pulmonary details - were segmented from the updated solution image. Based on the segmentation, an anatomical-adaptive weighting was applied to the TV-minimization step, so that TV-minimization was enhanced at noisy/streaky regions and suppressed at anatomical structures of interest. The image quality and convergence speed of AACS was compared to conventional ASD-POCS using an XCAT digital phantom and a patient scan. Results: For the XCAT phantom, the AACS image represented the ground truth better than the ASD-POCS image, giving a higher structural similarity index (0.93 vs. 0.84) and lower absolute difference (1.1*10{sup 4} vs. 1.4*10{sup 4}). For the patient case, while both algorithms resulted in much less noise and streaking than FDK, the AACS image showed considerably better contrast and sharpness of the vessels, tumor, and fiducial marker than the ASD-POCS image. In addition, AACS converged over 50% faster than ASD-POCS in both cases. Conclusions: The proposed AACS

  17. Evaluation of a projection-domain lung nodule insertion technique in thoracic CT

    NASA Astrophysics Data System (ADS)

    Ma, Chi; Chen, Baiyu; Koo, Chi Wan; Takahashi, Edwin A.; Fletcher, Joel G.; McCollough, Cynthia H.; Levin, David L.; Kuzo, Ronald S.; Viers, Lyndsay D.; Vincent Sheldon, Stephanie A.; Leng, Shuai; Yu, Lifeng

    2016-04-01

    Task-based assessment of computed tomography (CT) image quality requires a large number of cases with ground truth. Inserting lesions into existing cases to simulate positive cases is a promising alternative approach. The aim of this study was to evaluate a recently-developed raw-data based lesion insertion technique in thoracic CT. Lung lesions were segmented from patient CT images, forward projected, and reinserted into the same patient CT projection data. In total, 32 nodules of various attenuations were segmented from 21 CT cases. Two experienced radiologists and 2 residents blinded to the process independently evaluated these inserted nodules in two sub-studies. First, the 32 inserted and the 32 original nodules were presented in a randomized order and each received a rating score from 1 to 10 (1=absolutely artificial to 10=absolutely realistic). Second, the inserted and the corresponding original lesions were presented side-by-side to each reader, who identified the inserted lesion and provided a confidence score (1=no confidence to 5=completely certain). For the randomized evaluation, discrimination of real versus artificial nodules was poor with areas under the receiver operative characteristic curves being 0.69 (95% CI: 0.58-0.78), 0.57 (95% CI: 0.46-0.68), and 0.62 (95% CI: 0.54-0.69) for the 2 radiologists, 2 residents, and all 4 readers, respectively. For the side-by-side evaluation, although all 4 readers correctly identified inserted lesions in 103/128 pairs, the confidence score was moderate (2.6). Our projection-domain based lung nodule insertion technique provides a robust method to artificially generate clinical cases that prove to be difficult to differentiate from real cases.

  18. A fully automated calculation of size-specific dose estimates (SSDE) in thoracic and head CT examinations

    NASA Astrophysics Data System (ADS)

    Anam, C.; Haryanto, F.; Widita, R.; Arif, I.; Dougherty, G.

    2016-03-01

    The purpose of this study is to automatically calculate and then investigate the size- specific dose estimate (SSDE) in thoracic and head CT examinations undertaken using standard imaging protocols. The effective diameter (Deff ), the water equivalent diameter (Dw ), and the SSDE were calculated automatically from patient images. We investigated sixteen adult patients who underwent a CT head examination and thirty adult patients who underwent a CT thorax examination. Our results showed that the Dw value in the thoracic region was 4.5% lower than the value of Deff , while the Dw value in the head region was 8.6% higher than the value of Deff . The relationships between diameter (Deff and Dw ) and CTDIvol were distinctive. In the head region, decreasing the patient diameter resulted in a constant CTDIvol due to the tube current modulation (TCM) being off, while in the thoracic region decreasing the patient diameter resulted in a decrease in value of CTDIvol due to TCM being on. In the head region, decreasing the patient diameter resulted in an increase in the value of SSDE, while in the thoracic region decreasing the patient diameter resulted in a decrease in the value of SSDE.

  19. Simulation of dosimetric consequences of 4D-CT-based motion margin estimation for proton radiotherapy using patient tumor motion data

    NASA Astrophysics Data System (ADS)

    Koybasi, Ozhan; Mishra, Pankaj; St. James, Sara; Lewis, John H.; Seco, Joao

    2014-02-01

    For the radiation treatment of lung cancer patients, four-dimensional computed tomography (4D-CT) is a common practice used clinically to image tumor motion and subsequently determine the internal target volume (ITV) from the maximum intensity projection (MIP) images. ITV, which is derived from short pre-treatment 4D-CT scan (<6 s per couch position), may not adequately cover the extent of tumor motion during the treatment, particularly for patients that exhibit a large respiratory variability. Inaccurate tumor localization may result in under-dosage of the tumor or over-dosage of the surrounding tissues. The purpose of this study is therefore to assess the degree of tumor under-dosage in case of regular and irregular breathing for proton radiotherapy using ITV-based treatment planning. We place a spherical lesion into a modified XCAT phantom that is also capable of producing 4D images based on irregular breathing, and move the tumor according to real tumor motion data, which is acquired over multiple days by tracking gold fiducial markers implanted into the lung tumors of patients. We derive ITVs by taking the union of all tumor positions during 6 s of tumor motion in the phantom using the first day patient tumor tracking data. This is equivalent to ITVs generated clinically from cine-mode 4D-CT MIP images. The treatment plans created for different ITVs are then implemented on dynamic phantoms with tumor motion governed by real tumor tracking data from consecutive days. By comparing gross tumor volume dose distribution on days of ‘treatment’ with the ITV dose distribution, we evaluate the deviation of the actually delivered dose from the predicted dose. Our results have shown that the proton treatment planning on ITV derived from pre-treatment cine-mode 4D-CT can result in under-dosage (dose covering 95% of volume) of the tumor by up to 25.7% over 3 min of treatment for the patient with irregular respiratory motion. Tumor under-dosage is less significant for

  20. Performance evaluation and optimization of BM4D-AV denoising algorithm for cone-beam CT images

    NASA Astrophysics Data System (ADS)

    Huang, Kuidong; Tian, Xiaofei; Zhang, Dinghua; Zhang, Hua

    2015-12-01

    The broadening application of cone-beam Computed Tomography (CBCT) in medical diagnostics and nondestructive testing, necessitates advanced denoising algorithms for its 3D images. The block-matching and four dimensional filtering algorithm with adaptive variance (BM4D-AV) is applied to the 3D image denoising in this research. To optimize it, the key filtering parameters of the BM4D-AV algorithm are assessed firstly based on the simulated CBCT images and a table of optimized filtering parameters is obtained. Then, considering the complexity of the noise in realistic CBCT images, possible noise standard deviations in BM4D-AV are evaluated to attain the chosen principle for the realistic denoising. The results of corresponding experiments demonstrate that the BM4D-AV algorithm with optimized parameters presents excellent denosing effect on the realistic 3D CBCT images.

  1. SU-E-T-330: To Analyze the Calculation Error of Live Dose-Volume Indices Applying 4D-CT in Radiotherapy for PTVs Within the Liver Completely

    SciTech Connect

    Gong, G; Liu, C; Yin, Y

    2014-06-01

    Purpose: To study the variation rule of normal liver dose-volume indices calculation for the liver malignancy patients whose plan target volumes were in the liver completely in all breath phases. Methods: Ten patients who accepted radiotherapy for malignant tumor were selected in our study. All patients underwent 4D-CT simulation and 3D-CT simulation in free breathing(FB). 4D-CT was sorted into 10 series CT images according to breath phase, named CT0, CT10 to CT90, respectively. And GTVs were contoured on different CT series, and the individual target volume(ITV) was obtained by merging 10 GTVs from 4D-CT. The PTVs were obtained from ITV applying margins. The PTVs were not beyond the boundary of liver in all breath phase observed by dynamic 4D-CT. The radiotherapy plans were designed and irradiation dose was calculated on 3D-CT images, and the livers were contoured on different series CT images and mapped to 3D-CT images applying rigid registration. To compare the dose-volume difference of livers based on distinct CT images. Results: (1)The liver volumes were similar on 4D-CT and 3D-CT images(CTFB 1485±500cm{sup 3}, CT0 1413±377cm{sup 3}, CT10 1409±396cm{sup 3}, CT20 1419±418cm{sup 3},CT30 1485±500cm{sup 3}, CT40 1438±392cm{sup 3}, CT50 1437±404cm{sup 3}, CT60 1439±409cm{sup 3}, CT70 1408±393cm{sup 3}, CT80 1384±397cm{sup 3}, CT90 1398±397cm{sup 3}; F=0.064,p=1.00) (2) The PTVs volume were 30.17±14.62cm{sup 3};(3) The mean dose and V5 to V10 of liver were similar among 4D-CT different series CT images(p>0.05), and the indices varied less than ±4% refer to liver on CT50. Conclusion: The calculation affection of liver dose-volume indices induced by breath motion were not significant for the PTV within liver completely as estimation before. And more objective prediction indices for radiation induced l.

  2. Efficacy evaluation of retrospectively applying the Varian normal breathing predictive filter for volume definition and artifact reduction in 4D CT lung patients.

    PubMed

    Malone, Ciaran; Rock, Luke; Skourou, Christina

    2014-05-08

    Phase-based sorting of four-dimensional computed tomography (4D CT) datasets is prone to image artifacts due to patient's breathing irregularities that occur during the image acquisition. The purpose of this study is to investigate the effect of the Varian normal breathing predictive filter (NBPF) as a retrospective phase-sorting parameter in 4D CT. Ten 4D CT lung cancer datasets were obtained. The volumes of all tumors present, as well as the total lung volume, were calculated on the maximum intensity projection (MIP) images as well as each individual phase image. The NBPF was varied retrospectively within the available range, and changes in volume and image quality were recorded. The patients' breathing trace was analysed and the magnitude and location of any breathing irregularities were correlated to the behavior of the NBPF. The NBPF was found to have a considerable effect on the quality of the images in MIP and single-phase datasets. When used appropriately, the NBPF is shown to have the ability to account for and correct image artifacts. However, when turned off (0%) or set above a critical level (approximately 40%), it resulted in erroneous volume reconstructions with variations in tumor volume up to 26.6%. Those phases associated with peak inspiration were found to be more susceptible to changes in the NBPF. The NBPF settings selected prior to exporting the breathing trace for patients evaluated using 4D CT directly affect the accuracy of the targeting and volume estimation of lung tumors. Recommendations are made to address potential errors in patient anatomy introduced by breathing irregularities, specifically deep breath or cough irregularities, by implementing the proper settings and use of this tool.

  3. Comparison of planning target volumes based on three-dimensional and four-dimensional CT imaging of thoracic esophageal cancer

    PubMed Central

    Wang, Wei; Li, Jianbin; Zhang, Yingjie; Shao, Qian; Xu, Min; Fan, Tingyong; Wang, Jinzhi

    2016-01-01

    Background and purpose To investigate the definition of planning target volumes (PTVs) based on four-dimensional computed tomography (4DCT) compared with conventional PTV definition and PTV definition using asymmetrical margins for thoracic primary esophageal cancer. Materials and methods Forty-three patients with esophageal cancer underwent 3DCT and 4DCT simulation scans during free breathing. The motions of primary tumors located in the proximal (group A), middle (group B), and distal (group C) thoracic esophagus were obtained from the 4DCT scans. PTV3D was defined on 3DCT using the tumor motion measured based on 4DCT, PTV conventional (PTVconv) was defined on 3DCT by adding a 1.0 cm margin to the clinical target volume, and PTV4D was defined as the union of the target volumes contoured on the ten phases of the 4DCT images. The centroid positions, volumetric differences, and dice similarity coefficients were evaluated for all PTVs. Results The median centroid shifts between PTV3D and PTV4D and between PTVconv and PTV4D in all three dimensions were <0.3 cm for the three groups. The median size ratios of PTV4D to PTV3D were 0.80, 0.88, and 0.71, and PTV4D to PTVconv were 0.67, 0.73, and 0.76 (χ2=−3.18, −2.98, and −3.06; P=0.001, 0.003, and 0.002) for groups A, B, and C, respectively. The dice similarity coefficients were 0.87, 0.90, and 0.81 between PTV4D and PTV3D and 0.80, 0.84, and 0.83 between PTV4D and PTVconv (χ2 =−3.18, −2.98, and −3.06; P=0.001, 0.003, and 0.002) for groups A, B, and C, respectively. The difference between the degree of inclusion of PTV4D in PTV3D and that of PTV4D in PTVconv was <2% for all groups. Compared with PTVconv, the amount of irradiated normal tissue for PTV3D was decreased by 11.81% and 11.86% in groups A and B, respectively, but was increased by 2.93% in group C. Conclusion For proximal and middle esophageal cancer, 3DCT-based PTV using asymmetrical margins provides good coverage of PTV4D; however, for distal

  4. Thoracic computerized tomographic (CT) findings in 2009 influenza A (H1N1) virus infection in Isfahan, Iran

    PubMed Central

    Rostami, Mojtaba; Javadi, Abbas-Ali; Khorvash, Farzin; Mostafavizadeh, Kamyar; Adibi, Atoosa; Babak, Anahita; Ataei, Behrooz; Meidani, Mohsen; Naeini, Alireza Emami; Salehi, Hasan; Avijgan, Majid; Yazdani, Mohammad Reza; Rezaei, Farshid

    2011-01-01

    BACKGROUND: Pandemic 2009 H1N1 influenza A virus arrived at Isfahan in August 2009. The virus is still circulating in the world. The abnormal thoracic computerized tomographic (CT) scan findings vary widely among the studies of 2009 H1N1 influenza. We evaluated the thoracic CT findings in patients with 2009 H1N1 virus infection to describe findings compared to previously reported findings, and to suggest patterns that may be suggestive for 2009 influenza A (H1N1) in an appropriate clinical setting. METHODS: Retrospectively, the archive of all patients with a diagnosis of 2009 H1N1 influenza A were reviewed, in Al-Zahra Hospital in Isfahan, central Iran, between September 23rd 2009 to February 20th 2010. Out of 216 patients with confirmed 2009 influenza A (H1N1) virus, 26 cases with abnormal CT were enrolled in the study. Radiologic findings were characterized by the type and pattern of opacities and zonal distribution. RESULTS: Patchy infiltration (34.6%), lobar consolidation (30.8%), and interstitial infiltration (26.9%) with airbronchogram (38.5%) were the predominant findings in our patients. Bilateral distribution was seen in 80.8% of the patients. Only one patient (3.8%) showed ground-glass opacity, predominant radiographic finding in the previous reports and severe acute respiratory syndrome (SARS). CONCLUSIONS: The most common thoracic CT findings in pandemic H1N1 were patchy infiltration, lobar consolidation, and interstitial infiltration with airbronchogram and bilateral distribution. While these findings can be associated with other infections; they may be suggestive to 2009 influenza A (H1N1) in the appropriate clinical setting. Various radiographic patterns can be seen in thoracic CT scans of the influenza patients. Imaging findings are nonspecific. PMID:22091280

  5. TU-F-12A-05: Sensitivity of Textural Features to 3D Vs. 4D FDG-PET/CT Imaging in NSCLC Patients

    SciTech Connect

    Yang, F; Nyflot, M; Bowen, S; Kinahan, P; Sandison, G

    2014-06-15

    Purpose: Neighborhood Gray-level difference matrices (NGLDM) based texture parameters extracted from conventional (3D) 18F-FDG PET scans in patients with NSCLC have been previously shown to associate with response to chemoradiation and poorer patient outcome. However, the change in these parameters when utilizing respiratory-correlated (4D) FDG-PET scans has not yet been characterized for NSCLC. The Objectives: of this study was to assess the extent to which NGLDM-based texture parameters on 4D PET images vary with reference to values derived from 3D scans in NSCLC. Methods: Eight patients with newly diagnosed NSCLC treated with concomitant chemoradiotherapy were included in this study. 4D PET scans were reconstructed with OSEM-IR in 5 respiratory phase-binned images and corresponding CT data of each phase were employed for attenuation correction. NGLDM-based texture features, consisting of coarseness, contrast, busyness, complexity and strength, were evaluated for gross tumor volumes defined on 3D/4D PET scans by radiation oncologists. Variation of the obtained texture parameters over the respiratory cycle were examined with respect to values extracted from 3D scans. Results: Differences between texture parameters derived from 4D scans at different respiratory phases and those extracted from 3D scans ranged from −30% to 13% for coarseness, −12% to 40% for contrast, −5% to 50% for busyness, −7% to 38% for complexity, and −43% to 20% for strength. Furthermore, no evident correlations were observed between respiratory phase and 4D scan texture parameters. Conclusion: Results of the current study showed that NGLDM-based texture parameters varied considerably based on choice of 3D PET and 4D PET reconstruction of NSCLC patient images, indicating that standardized image acquisition and analysis protocols need to be established for clinical studies, especially multicenter clinical trials, intending to validate prognostic values of texture features for NSCLC.

  6. Imaging and dosimetric errors in 4D PET/CT-guided radiotherapy from patient-specific respiratory patterns: a dynamic motion phantom end-to-end study

    NASA Astrophysics Data System (ADS)

    Bowen, S. R.; Nyflot, M. J.; Herrmann, C.; Groh, C. M.; Meyer, J.; Wollenweber, S. D.; Stearns, C. W.; Kinahan, P. E.; Sandison, G. A.

    2015-05-01

    Effective positron emission tomography / computed tomography (PET/CT) guidance in radiotherapy of lung cancer requires estimation and mitigation of errors due to respiratory motion. An end-to-end workflow was developed to measure patient-specific motion-induced uncertainties in imaging, treatment planning, and radiation delivery with respiratory motion phantoms and dosimeters. A custom torso phantom with inserts mimicking normal lung tissue and lung lesion was filled with [18F]FDG. The lung lesion insert was driven by six different patient-specific respiratory patterns or kept stationary. PET/CT images were acquired under motionless ground truth, tidal breathing motion-averaged (3D), and respiratory phase-correlated (4D) conditions. Target volumes were estimated by standardized uptake value (SUV) thresholds that accurately defined the ground-truth lesion volume. Non-uniform dose-painting plans using volumetrically modulated arc therapy were optimized for fixed normal lung and spinal cord objectives and variable PET-based target objectives. Resulting plans were delivered to a cylindrical diode array at rest, in motion on a platform driven by the same respiratory patterns (3D), or motion-compensated by a robotic couch with an infrared camera tracking system (4D). Errors were estimated relative to the static ground truth condition for mean target-to-background (T/Bmean) ratios, target volumes, planned equivalent uniform target doses, and 2%-2 mm gamma delivery passing rates. Relative to motionless ground truth conditions, PET/CT imaging errors were on the order of 10-20%, treatment planning errors were 5-10%, and treatment delivery errors were 5-30% without motion compensation. Errors from residual motion following compensation methods were reduced to 5-10% in PET/CT imaging, <5% in treatment planning, and <2% in treatment delivery. We have demonstrated that estimation of respiratory motion uncertainty and its propagation from PET/CT imaging to RT planning, and RT

  7. Imaging and dosimetric errors in 4D PET/CT-guided radiotherapy from patient-specific respiratory patterns: a dynamic motion phantom end-to-end study

    PubMed Central

    Bowen, S R; Nyflot, M J; Hermann, C; Groh, C; Meyer, J; Wollenweber, S D; Stearns, C W; Kinahan, P E; Sandison, G A

    2015-01-01

    Effective positron emission tomography/computed tomography (PET/CT) guidance in radiotherapy of lung cancer requires estimation and mitigation of errors due to respiratory motion. An end-to-end workflow was developed to measure patient-specific motion-induced uncertainties in imaging, treatment planning, and radiation delivery with respiratory motion phantoms and dosimeters. A custom torso phantom with inserts mimicking normal lung tissue and lung lesion was filled with [18F]FDG. The lung lesion insert was driven by 6 different patient-specific respiratory patterns or kept stationary. PET/CT images were acquired under motionless ground truth, tidal breathing motion-averaged (3D), and respiratory phase-correlated (4D) conditions. Target volumes were estimated by standardized uptake value (SUV) thresholds that accurately defined the ground-truth lesion volume. Non-uniform dose-painting plans using volumetrically modulated arc therapy (VMAT) were optimized for fixed normal lung and spinal cord objectives and variable PET-based target objectives. Resulting plans were delivered to a cylindrical diode array at rest, in motion on a platform driven by the same respiratory patterns (3D), or motion-compensated by a robotic couch with an infrared camera tracking system (4D). Errors were estimated relative to the static ground truth condition for mean target-to-background (T/Bmean) ratios, target volumes, planned equivalent uniform target doses (EUD), and 2%-2mm gamma delivery passing rates. Relative to motionless ground truth conditions, PET/CT imaging errors were on the order of 10–20%, treatment planning errors were 5–10%, and treatment delivery errors were 5–30% without motion compensation. Errors from residual motion following compensation methods were reduced to 5–10% in PET/CT imaging, < 5% in treatment planning, and < 2% in treatment delivery. We have demonstrated that estimation of respiratory motion uncertainty and its propagation from PET/CT imaging to RT

  8. Pseudoaneurysm of the thoracic aorta sustained during exposure to a tornado diagnosed with ECG-synchronized CT aortography.

    PubMed

    Chakraborty, Amit; von Herrmann, Paul F; Embertson, Ryan E; Landwehr, Kevin P; Winkler, Michael A

    2016-01-01

    A case of a tornado victim with a delayed presentation of injury to the aortic isthmus is discussed. Tornado forces resemble the forces of high energy explosions, and the injuries that can occur as a result of these forces can be bizarre. The patient presented with the unique computed tomography (CT) findings of isolated pseudoaneurysm of the thoracic aorta in the absence of other traumatic injury to the thorax. Equivocal results of the initial CT aortogram (CTA) were confirmed with ECG-synchronized CTA (ECG-CTA), demonstrating the superiority of ECG-CTA as compared to standard CTA. PMID:27317209

  9. Pseudoaneurysm of the thoracic aorta sustained during exposure to a tornado diagnosed with ECG-synchronized CT aortography.

    PubMed

    Chakraborty, Amit; von Herrmann, Paul F; Embertson, Ryan E; Landwehr, Kevin P; Winkler, Michael A

    2016-01-01

    A case of a tornado victim with a delayed presentation of injury to the aortic isthmus is discussed. Tornado forces resemble the forces of high energy explosions, and the injuries that can occur as a result of these forces can be bizarre. The patient presented with the unique computed tomography (CT) findings of isolated pseudoaneurysm of the thoracic aorta in the absence of other traumatic injury to the thorax. Equivocal results of the initial CT aortogram (CTA) were confirmed with ECG-synchronized CTA (ECG-CTA), demonstrating the superiority of ECG-CTA as compared to standard CTA.

  10. Automatic detection of large pulmonary solid nodules in thoracic CT images

    SciTech Connect

    Setio, Arnaud A. A. Jacobs, Colin; Gelderblom, Jaap; Ginneken, Bram van

    2015-10-15

    Purpose: Current computer-aided detection (CAD) systems for pulmonary nodules in computed tomography (CT) scans have a good performance for relatively small nodules, but often fail to detect the much rarer larger nodules, which are more likely to be cancerous. We present a novel CAD system specifically designed to detect solid nodules larger than 10 mm. Methods: The proposed detection pipeline is initiated by a three-dimensional lung segmentation algorithm optimized to include large nodules attached to the pleural wall via morphological processing. An additional preprocessing is used to mask out structures outside the pleural space to ensure that pleural and parenchymal nodules have a similar appearance. Next, nodule candidates are obtained via a multistage process of thresholding and morphological operations, to detect both larger and smaller candidates. After segmenting each candidate, a set of 24 features based on intensity, shape, blobness, and spatial context are computed. A radial basis support vector machine (SVM) classifier was used to classify nodule candidates, and performance was evaluated using ten-fold cross-validation on the full publicly available lung image database consortium database. Results: The proposed CAD system reaches a sensitivity of 98.3% (234/238) and 94.1% (224/238) large nodules at an average of 4.0 and 1.0 false positives/scan, respectively. Conclusions: The authors conclude that the proposed dedicated CAD system for large pulmonary nodules can identify the vast majority of highly suspicious lesions in thoracic CT scans with a small number of false positives.

  11. The relationship between organ dose and patient size in tube current modulated adult thoracic CT scans

    NASA Astrophysics Data System (ADS)

    Khatonabadi, Maryam; Zhang, Di; Yang, Jeffrey; DeMarco, John J.; Cagnon, Chris C.; McNitt-Gray, Michael F.

    2012-03-01

    Recently published AAPM Task Group 204 developed conversion coefficients that use scanner reported CTDIvol to estimate dose to the center of patient undergoing fixed tube current body exam. However, most performed CT exams use TCM to reduce dose to patients. Therefore, the purpose of this study was to investigate the correlation between organ dose and a variety of patient size metrics in adult chest CT scans that use tube current modulation (TCM). Monte Carlo simulations were performed for 32 voxelized models with contoured lungs and glandular breasts tissue, consisting of females and males. These simulations made use of patient's actual TCM data to estimate organ dose. Using image data, different size metrics were calculated, these measurements were all performed on one slice, at the level of patient's nipple. Estimated doses were normalized by scanner-reported CTDIvol and plotted versus different metrics. CTDIvol values were plotted versus different metrics to look at scanner's output versus size. The metrics performed similarly in terms of correlating with organ dose. Looking at each gender separately, for male models normalized lung dose showed a better linear correlation (r2=0.91) with effective diameter, while female models showed higher correlation (r2=0.59) with the anterior-posterior measurement. There was essentially no correlation observed between size and CTDIvol-normalized breast dose. However, a linear relationship was observed between absolute breast dose and size. Dose to lungs and breasts were consistently higher in females with similar size as males which could be due to shape and composition differences between genders in the thoracic region.

  12. Cardiac C-arm CT: 4D non-model based heart motion estimation and its application

    NASA Astrophysics Data System (ADS)

    Prümmer, M.; Fahrig, R.; Wigström, L.; Boese, J.; Lauritsch, G.; Strobel, N.; Hornegger, J.

    2007-03-01

    The combination of real-time fluoroscopy and 3D cardiac imaging on the same C-arm system is a promising technique that might improve therapy planning, guiding, and monitoring in the interventional suite. In principal, to reconstruct a 3D image of the beating heart at a particular cardiac phase, a complete set of X-ray projection data representing that phase is required. One approximate approach is the retrospectively ECG-gated FDK reconstruction (RG-FDK). From the acquired data set of N s multiple C-arm sweeps, those projection images which are acquired closest in time to the desired cardiac phase are retrospectively selected. However, this approach uses only 1/ N s of the obtained data. Our goal is to utilize data from other cardiac phases as well. In order to minimize blurring and motion artifacts, cardiac motion has to be compensated for, which can be achieved using a temporally dependent spatial 3D warping of the filtered-backprojections. In this work we investigate the computation of the 4D heart motion based on prior reconstructions of several cardiac phases using RG-FDK. A 4D motion estimation framework is presented using standard fast non-rigid registration. A smooth 4D motion vector field (MVF) represents the relative deformation compared to a reference cardiac phase. A 4D deformation regridding by adaptive supersampling allows selecting any reference phase independently of the set of phases used in the RG-FDK for a motion corrected reconstruction. Initial promising results from in vivo experiments are shown. The subjects individual 4D cardiac MVF could be computed from only three RG-FDK image volumes. In addition, all acquired projection data were motion corrected and subsequently used for image reconstruction to improve the signal-to-noise ratio compared to RG-FDK.

  13. SU-E-J-151: Dosimetric Evaluation of DIR Mapped Contours for Image Guided Adaptive Radiotherapy with 4D Cone-Beam CT

    SciTech Connect

    Balik, S; Weiss, E; Williamson, J; Hugo, G; Jan, N; Zhang, L; Roman, N; Christensen, G

    2014-06-01

    Purpose: To estimate dosimetric errors resulting from using contours deformably mapped from planning CT to 4D cone beam CT (CBCT) images for image-guided adaptive radiotherapy of locally advanced non-small cell lung cancer (NSCLC). Methods: Ten locally advanced non-small cell lung cancer (NSCLC) patients underwent one planning 4D fan-beam CT (4DFBCT) and weekly 4DCBCT scans. Multiple physicians delineated the gross tumor volume (GTV) and normal structures in planning CT images and only GTV in CBCT images. Manual contours were mapped from planning CT to CBCTs using small deformation, inverse consistent linear elastic (SICLE) algorithm for two scans in each patient. Two physicians reviewed and rated the DIR-mapped (auto) and manual GTV contours as clinically acceptable (CA), clinically acceptable after minor modification (CAMM) and unacceptable (CU). Mapped normal structures were visually inspected and corrected if necessary, and used to override tissue density for dose calculation. CTV (6mm expansion of GTV) and PTV (5mm expansion of CTV) were created. VMAT plans were generated using the DIR-mapped contours to deliver 66 Gy in 33 fractions with 95% and 100% coverage (V66) to PTV and CTV, respectively. Plan evaluation for V66 was based on manual PTV and CTV contours. Results: Mean PTV V66 was 84% (range 75% – 95%) and mean CTV V66 was 97% (range 93% – 100%) for CAMM scored plans (12 plans); and was 90% (range 80% – 95%) and 99% (range 95% – 100%) for CA scored plans (7 plans). The difference in V66 between CAMM and CA was significant for PTV (p = 0.03) and approached significance for CTV (p = 0.07). Conclusion: The quality of DIR-mapped contours directly impacted the plan quality for 4DCBCT-based adaptation. Larger safety margins may be needed when planning with auto contours for IGART with 4DCBCT images. Reseach was supported by NIH P01CA116602.

  14. 4D cone-beam CT imaging for guidance in radiation therapy: setup verification by use of implanted fiducial markers

    NASA Astrophysics Data System (ADS)

    Jin, Peng; van Wieringen, Niek; Hulshof, Maarten C. C. M.; Bel, Arjan; Alderliesten, Tanja

    2016-03-01

    The use of 4D cone-beam computed tomography (CBCT) and fiducial markers for guidance during radiation therapy of mobile tumors is challenging due to the trade-off between image quality, imaging dose, and scanning time. We aimed to investigate the visibility of markers and the feasibility of marker-based 4D registration and manual respiration-induced marker motion quantification for different CBCT acquisition settings. A dynamic thorax phantom and a patient with implanted gold markers were included. For both the phantom and patient, the peak-to-peak amplitude of marker motion in the cranial-caudal direction ranged from 5.3 to 14.0 mm, which did not affect the marker visibility and the associated marker-based registration feasibility. While using a medium field of view (FOV) and the same total imaging dose as is applied for 3D CBCT scanning in our clinic, it was feasible to attain an improved marker visibility by reducing the imaging dose per projection and increasing the number of projection images. For a small FOV with a shorter rotation arc but similar total imaging dose, streak artifacts were reduced due to using a smaller sampling angle. Additionally, the use of a small FOV allowed reducing total imaging dose and scanning time (~2.5 min) without losing the marker visibility. In conclusion, by using 4D CBCT with identical or lower imaging dose and a reduced gantry speed, it is feasible to attain sufficient marker visibility for marker-based 4D setup verification. Moreover, regardless of the settings, manual marker motion quantification can achieve a high accuracy with the error <1.2 mm.

  15. Preliminary study of visualizing membrane structures of spiculated pulmonary nodules in three-dimensional thoracic CT images

    NASA Astrophysics Data System (ADS)

    Kawata, Y.; Niki, N.; Ohmatsu, H.; Aokage, K.; Kusumoto, M.; Tsuchida, T.; Eguchi, K.; Kaneko, M.

    2016-03-01

    Research results from the National Lung Screening Trial revealed that screening for lung cancer with low-dose CT (LDCT) reduces lung cancer mortality in heavy smokers by 20% compared to radiography. While this study does show the efficacy of CT-based screening, radiologists often face the problem of estimating the malignant likelihoods of pulmonary nodules detected on LDCT screening for maximizing patient survival and for preserving lung function. Spiculation is considered as one of the indicators of nodule malignancy and an important feature to assess requirements on a patient-tailored follow-up procedure. However, the spiculation is also observed in some benign nodules, particularly in tuberculoma. The elucidation of the spliculation morphology in 3D thoracic CT images is an important preliminary step towards developing the malignant discrimination strategies from benign nodules. In this study, we present a visualization method to reveal a spatial configuration of spiculation of pulmonary nodules in three-dimensional thoracic CT images. Applying the method to an example of malignant nodule with the spiculated margins, the visualizing preliminary result of the spatial configuration reveals the presence of membrane structures of spiculation.

  16. High-Resolution 4D Imaging of Technetium Transport in Porous Media using Preclinical SPECT-CT

    NASA Astrophysics Data System (ADS)

    Dogan, M.; DeVol, T. A.; Groen, H.; Moysey, S. M.; Ramakers, R.; Powell, B. A.

    2015-12-01

    Preclinical SPECT-CT (single-photon emission computed tomography with integrated X-ray computed tomography) offers the potential to quantitatively image the dynamic three-dimensional distribution of radioisotopes with sub-millimeter resolution, overlaid with structural CT images (20-200 micron resolution), making this an attractive method for studying transport in porous media. A preclinical SPECT-CT system (U-SPECT4CT, MILabs BV. Utrecht, The Netherlands) was evaluated for imaging flow and transport of 99mTc (t1/2=6hrs) using a 46,5mm by 156,4mm column packed with individual layers consisting of <0.2mm diameter silica gel, 0.2-0.25, 0.5, 1.0, 2.0, 3.0, and 4.0mm diameter glass beads, and a natural soil sample obtained from the Savannah River Site. The column was saturated with water prior to injecting the 99mTc solution. During the injection the flow was interrupted intermittently for 10 minute periods to allow for the acquisition of a SPECT image of the transport front. Non-uniformity of the front was clearly observed in the images as well as the retarded movement of 99mTc in the soil layer. The latter is suggesting good potential for monitoring transport processes occurring on the timescale of hours. After breakthrough of 99mTc was achieved, the flow was stopped and SPECT data were collected in one hour increments to evaluate the sensitivity of the instrument as the isotope decayed. Fused SPECT- CT images allowed for improved interpretation of 99mTc distributions within individual pore spaces. With ~3 MBq remaining in the column, the lowest activity imaged, it was not possible to clearly discriminate any of the pore spaces.

  17. Toward time resolved 4D cardiac CT imaging with patient dose reduction: estimating the global heart motion

    NASA Astrophysics Data System (ADS)

    Taguchi, Katsuyuki; Segars, W. Paul; Fung, George S. K.; Tsui, Benjamin M. W.

    2006-03-01

    Coronary artery imaging with multi-slice helical computed tomography is a promising noninvasive imaging technique. The current major issues include the insufficient temporal resolution and large patient dose. We propose an image reconstruction method which provides a solution to both of the problems. The method uses an iterative approach repeating the following four steps until the difference between the two projection data sets falls below a certain criteria in step-4: 1) estimating or updating the cardiac motion vectors, 2) reconstructing the time-resolved 4D dynamic volume images using the motion vectors, 3) calculating the projection data from the current 4D images, 4) comparing them with the measured ones. In this study, we obtain the first estimate of the motion vector. We use the 4D NCAT phantom, a realistic computer model for the human anatomy and cardiac motions, to generate the dynamic fan-beam projection data sets as well to provide a known truth for the motion. Then, the halfscan reconstruction with the sliding time-window technique is used to generate cine images: f(t, r r). Here, we use one heart beat for each position r so that the time information is retained. Next, the magnitude of the first derivative of f(t, r r) with respect to time, i.e., |df/dt|, is calculated and summed over a region-of-interest (ROI), which is called the mean-absolute difference (MAD). The initial estimation of the vector field are obtained using MAD for each ROI. Results of the preliminary study are presented.

  18. SU-E-J-267: Weekly Volumetric and Dosimetric Changes in Adaptive Conformal Radiotherapy of Non-Small-Cell-Lung Cancer Using 4D CT and Gating

    SciTech Connect

    Li, Z; Shang, Q; Xiong, F; Zhang, X; Zhang, Q; Fu, S

    2014-06-01

    Purpose: This study was to evaluate the significance of weekly imageguided patient setup and to assess the volumetric and dosimetric changes in no-small-cell-lung cancer (NSCLC) patients treated with adaptive conformal radiotherapy (CRT). Methods: 9 NSCLC patients treated with 3D CRT underwent 4D CT-on-rail every five fractions. ITV was generated from three phases of the 4DCT (the end of exhalation, 25% before and after the end of exhalation). The margin of ITV to PTV is 5mm. 6 weekly CTs were acquired for each patient. The weekly CTs were fused with the planning CT by vertebrae. The couch shift was recorded for each weekly CT to evaluate the setup error. The gross tumor volumes (GTVs) were contoured on weekly CT images by a physician. Beams from the original plans were applied to weekly CTs to calculate the delivered doses. All patients underwent replanning after 20 fractions. Results: Among the total 54 CTs, the average setup error was 2.0± 1.7, 2.6± 2.1, 2.7± 2.2 mm in X, Y, and Z direction, respectively. The average volume of the primary GTV was reduced from 42.45 cc to 22.78 cc (47.04%) after 6 weeks. The maximal volume regression occurred between 15 and 20 fractions. Adaptive radiation therapy (ART) reduced the V20 and V5 of the lung by 33.5% and 16.89%, respectively. ART also reduced Dmean and D1/3 of the heart by 31.7% and 32.32%, respectively. Dmax of the spinal cord did not vary much during the treatment course. Conclusion: 5 mm margin is sufficient for 4D weekly CTguided radiotherapy in lung cancer. Tumor regression was observed in the majority of patients. ART significantly reduced the OARs dose. Our preliminary results indicated that an off-line ART approach is appropriate in clinical practice.

  19. Feasibility of quantitative lung perfusion by 4D CT imaging by a new dynamic-scanning protocol in an animal model

    NASA Astrophysics Data System (ADS)

    Wang, Yang; Goldin, Jonathan G.; Abtin, Fereidoun G.; Brown, Matt; McNitt-Gray, Mike

    2008-03-01

    The purpose of this study is to test a new dynamic Perfusion-CT imaging protocol in an animal model and investigate the feasibility of quantifying perfusion of lung parenchyma to perform functional analysis from 4D CT image data. A novel perfusion-CT protocol was designed with 25 scanning time points: the first at baseline and 24 scans after a bolus injection of contrast material. Post-contrast CT scanning images were acquired with a high sampling rate before the first blood recirculation and then a relatively low sampling rate until 10 minutes after administrating contrast agent. Lower radiation techniques were used to keep the radiation dose to an acceptable level. 2 Yorkshire swine with pulmonary emboli underwent this perfusion- CT protocol at suspended end inspiration. The software tools were designed to measure the quantitative perfusion parameters (perfusion, permeability, relative blood volume, blood flow, wash-in & wash-out enhancement) of voxel or interesting area of lung. The perfusion values were calculated for further lung functional analysis and presented visually as contrast enhancement maps for the volume being examined. The results show increased CT temporal sampling rate provides the feasibility of quantifying lung function and evaluating the pulmonary emboli. Differences between areas with known perfusion defects and those without perfusion defects were observed. In conclusion, the techniques to calculate the lung perfusion on animal model have potential application in human lung functional analysis such as evaluation of functional effects of pulmonary embolism. With further study, these techniques might be applicable in human lung parenchyma characterization and possibly for lung nodule characterization.

  20. Semiautomatic technique for defining the internal gross tumor volume of lung tumors close to liver/spleen cupola by 4D-CT

    SciTech Connect

    Mancosu, Pietro; Sghedoni, Roberto; Bettinardi, Valentino; Aquilina, Mark Anthony; Navarria, Piera; Cattaneo, Giovanni Mauro; Di Muzio, Nadia; Cozzi, Luca; Scorsetti, Marta

    2010-09-15

    Purpose: It has been shown that in cases of lung tumors close to the liver cupola, the four dimensional (4D)-CT postprocessing maximum intensity projection (MIP) algorithm does not fully recover the radiotherapy internal gross tumor volume (IGTV). In this work, a semiautomatic technique was evaluated by which the residual IGTV that was not included into the IGTV by MIP algorithm was actually added. Methods: A moving phantom and five selected patients were considered. The various IGTVs produced by the semiautomatic approach were compared to those generated by 4D-CT manual contouring. Results: In all cases, the radiation oncologist qualitatively concurred with the semiautomatic IGTV. A quantitative difference in volume of 2.6% was found in the phantom study, whereas a mean difference of 0.1{+-}4.6% was obtained in the patient studies. Conclusions: A semiautomatic technique to include the residual part of IGTV covered by liver/spleen cupola when using MIP algorithm was validated on phantom and on selected patients, revealing the possibility of defining the IGTV for patients with lesions located near liver/spleen cupola by performing only the contours on the MIP series.

  1. Tumor Tracking Method Based on a Deformable 4D CT Breathing Motion Model Driven by an External Surface Surrogate

    SciTech Connect

    Fassi, Aurora; Schaerer, Joël; Fernandes, Mathieu; Riboldi, Marco; Sarrut, David; Baroni, Guido

    2014-01-01

    Purpose: To develop a tumor tracking method based on a surrogate-driven motion model, which provides noninvasive dynamic localization of extracranial targets for the compensation of respiration-induced intrafraction motion in high-precision radiation therapy. Methods and Materials: The proposed approach is based on a patient-specific breathing motion model, derived a priori from 4-dimensional planning computed tomography (CT) images. Model parameters (respiratory baseline, amplitude, and phase) are retrieved and updated at each treatment fraction according to in-room radiography acquisition and optical surface imaging. The baseline parameter is adapted to the interfraction variations obtained from the daily cone beam (CB) CT scan. The respiratory amplitude and phase are extracted from an external breathing surrogate, estimated from the displacement of the patient thoracoabdominal surface, acquired with a noninvasive surface imaging device. The developed method was tested on a database of 7 lung cancer patients, including the synchronized information on internal and external respiratory motion during a CBCT scan. Results: About 30 seconds of simultaneous acquisition of CBCT and optical surface images were analyzed for each patient. The tumor trajectories identified in CBCT projections were used as reference and compared with the target trajectories estimated from surface displacement with the a priori motion model. The resulting absolute differences between the reference and estimated tumor motion along the 2 image dimensions ranged between 0.7 and 2.4 mm; the measured phase shifts did not exceed 7% of the breathing cycle length. Conclusions: We investigated a tumor tracking method that integrates breathing motion information provided by the 4-dimensional planning CT with surface imaging at the time of treatment, representing an alternative approach to point-based external–internal correlation models. Although an in-room radiograph-based assessment of the

  2. SU-D-17A-03: 5D Respiratory Motion Model Based Iterative Reconstruction Method for 4D Cone-Beam CT

    SciTech Connect

    Gao, Y; Thomas, D; Low, D; Gao, H

    2014-06-01

    Purpose: The purpose of this work is to develop a new iterative reconstruction method for 4D cone-beam CT (CBCT) based on a published time-independent 5D respiratory motion model. The proposed method will offer a single high-resolution image at a user-selected breathing phase and the 5D motion model parameters, which could be used to generate the breathing pattern during the CT acquisition. Methods: 5D respiratory motion model was proposed for accurately modeling the motion of lung and lung tumor tissues. 4D images are then parameterized by a reference image, measured breathing amplitude, breathing rate, two time-independent vector fields that describe the 5D model parameters, and a scalar field that describes the change in HU as a function of breathing amplitude. In contrast with the traditional method of reconstructing multiple temporal image phases to reduce respiratory artifact, 5D model based method simplify the problem into the reconstruction of a single reference image and the 5D motion model parameters. The reconstruction formulation of the reference image and scalar and vector fields is a nonlinear least-square optimization problem that consists of solving the reference image and fields alternately, in which the reference image is regularized with the total variation sparsity transform and the vector fields are solved through linearizations regularized by the H1 norm. 2D lung simulations were performed in this proof-of-concept study. Results: The breathing amplitude, its rate, and the corresponding scalar and vector fields were generated from a patient case. Compared with filtered backprojection method and sparsity regularized iterative method for the phase-by-phase reconstruction, the proposed 5D motion model based method yielded improved image quality. Conclusion: Based on 5D respiratory motion model, we have developed a new iterative reconstruction method for 4D CBCT that has the potential for improving image quality while providing needed on

  3. SU-D-201-07: Exploring the Utility of 4D FDG-PET/CT Scans in Design of Radiation Therapy Planning Compared with 3D PET/CT: A Prospective Study

    SciTech Connect

    Ma, C; Yin, Y

    2015-06-15

    Purpose: A method using four-dimensional(4D) PET/CT in design of radiation treatment planning was proposed and the target volume and radiation dose distribution changes relative to standard three-dimensional (3D) PET/CT were examined. Methods: A target deformable registration method was used by which the whole patient’s respiration process was considered and the effect of respiration motion was minimized when designing radiotherapy planning. The gross tumor volume of a non-small-cell lung cancer was contoured on the 4D FDG-PET/CT and 3D PET/CT scans by use of two different techniques: manual contouring by an experienced radiation oncologist using a predetermined protocol; another technique using a constant threshold of standardized uptake value (SUV) greater than 2.5. The target volume and radiotherapy dose distribution between VOL3D and VOL4D were analyzed. Results: For all phases, the average automatic and manually GTV volume was 18.61 cm3 (range, 16.39–22.03 cm3) and 31.29 cm3 (range, 30.11–35.55 cm3), respectively. The automatic and manually volume of merged IGTV were 27.82 cm3 and 49.37 cm3, respectively. For the manual contour, compared to 3D plan the mean dose for the left, right, and total lung of 4D plan have an average decrease 21.55%, 15.17% and 15.86%, respectively. The maximum dose of spinal cord has an average decrease 2.35%. For the automatic contour, the mean dose for the left, right, and total lung have an average decrease 23.48%, 16.84% and 17.44%, respectively. The maximum dose of spinal cord has an average decrease 1.68%. Conclusion: In comparison to 3D PET/CT, 4D PET/CT may better define the extent of moving tumors and reduce the contouring tumor volume thereby optimize radiation treatment planning for lung tumors.

  4. An automated landmark-based elastic registration technique for large deformation recovery from 4-D CT lung images

    NASA Astrophysics Data System (ADS)

    Negahdar, Mohammadreza; Zacarias, Albert; Milam, Rebecca A.; Dunlap, Neal; Woo, Shiao Y.; Amini, Amir A.

    2012-03-01

    The treatment plan evaluation for lung cancer patients involves pre-treatment and post-treatment volume CT imaging of the lung. However, treatment of the tumor volume lung results in structural changes to the lung during the course of treatment. In order to register the pre-treatment volume to post-treatment volume, there is a need to find robust and homologous features which are not affected by the radiation treatment along with a smooth deformation field. Since airways are well-distributed in the entire lung, in this paper, we propose use of airway tree bifurcations for registration of the pre-treatment volume to the post-treatment volume. A dedicated and automated algorithm has been developed that finds corresponding airway bifurcations in both images. To derive the 3-D deformation field, a B-spline transformation model guided by mutual information similarity metric was used to guarantee the smoothness of the transformation while combining global information from bifurcation points. Therefore, the approach combines both global statistical intensity information with local image feature information. Since during normal breathing, the lung undergoes large nonlinear deformations, it is expected that the proposed method would also be applicable to large deformation registration between maximum inhale and maximum exhale images in the same subject. The method has been evaluated by registering 3-D CT volumes at maximum exhale data to all the other temporal volumes in the POPI-model data.

  5. A case of malignant peritoneal mesothelioma revealed with limitation of PET-CT in the diagnosis of thoracic metastasis

    PubMed Central

    Saraya, Takeshi; Yokoyama, Takuma; Ishii, Haruyuki; Tanaka, Yasutaka; Tsujimoto, Naoki; Ogawa, Yukari; Sohara, Erei; Nakajima, Akira; Inui, Toshiya; Sayuki, Hiraoka; Fujiwara, Masachika; Oka, Teruaki; Kawachi, Riken; Goya, Tomoyuki; Takizawa, Hajime

    2013-01-01

    A 47-year-old man was referred to our hospital because of a 2-month history of dry cough, 2-kg weight loss, and a feeling of abdominal fullness. The PET-CT scan depicts the intense standard uptake values (SUVs) of the anterior and subphrenic lymphnodes, and intraperitoneal cavity, especially in the omentum, while, no uptake was found in the pleural cavity. Based on the pathological findings of the open lung biopsy specimens, he was diagnosed with malignant peritoneal mesothelioma of epithelioid type with thoracic metastasis. The present case demonstrated the some of the limitations of PET-CT in the diagnosis of malignant mesothelioma, which failed to detect pleural involvement despite aggressive invasion by this tumor. PMID:23372960

  6. Fuzzy Clustering Applied to ROI Detection in Helical Thoracic CT Scans with a New Proposal and Variants.

    PubMed

    Castro, Alfonso; Rey, Alberto; Boveda, Carmen; Arcay, Bernardino; Sanjurjo, Pedro

    2016-01-01

    The detection of pulmonary nodules is one of the most studied problems in the field of medical image analysis due to the great difficulty in the early detection of such nodules and their social impact. The traditional approach involves the development of a multistage CAD system capable of informing the radiologist of the presence or absence of nodules. One stage in such systems is the detection of ROI (regions of interest) that may be nodules in order to reduce the space of the problem. This paper evaluates fuzzy clustering algorithms that employ different classification strategies to achieve this goal. After characterising these algorithms, the authors propose a new algorithm and different variations to improve the results obtained initially. Finally it is shown as the most recent developments in fuzzy clustering are able to detect regions that may be nodules in CT studies. The algorithms were evaluated using helical thoracic CT scans obtained from the database of the LIDC (Lung Image Database Consortium).

  7. Multimodality thoracic imaging of juvenile systemic sclerosis: emphasis on clinical correlation and high-resolution CT of pulmonary fibrosis.

    PubMed

    Valeur, Natalie S; Stevens, Anne M; Ferguson, Mark R; Effmann, Eric L; Iyer, Ramesh S

    2015-02-01

    OBJECTIVE. Juvenile systemic sclerosis is a rare multisystem autoimmune disorder characterized by vasculopathy and multiorgan fibrosis. Cardiopulmonary complications are the leading cause of morbidity and mortality. Although pulmonary fibrosis is the complication that is most common and well described, cardiovascular and esophageal involvement may also be observed. In this article, common thoracic findings in juvenile systemic sclerosis will be discussed. We will focus on chest CT, including CT findings of pulmonary fibrosis and associated grading methods, as well as cardiac MRI and esophageal imaging. CONCLUSION. Radiologists play a pivotal role in the initial diagnosis and follow-up evaluation of pediatric patients with systemic sclerosis. Treatment decisions and prognostic assessment are directly related to imaging findings along with clinical evaluation.

  8. A knowledge-driven quasi-global registration of thoracic-abdominal CT and CBCT for image-guided interventions

    NASA Astrophysics Data System (ADS)

    Zhang, Li; Chefd'hotel, Christophe; Ordy, Vincent; Zheng, Jie; Deng, Xiang; Odry, Benjamin

    2013-03-01

    In this work, we have developed a novel knowledge-driven quasi-global method for fast and robust registration of thoracic-abdominal CT and cone beam CT (CBCT) scans. While the use of CBCT in operating rooms has become a common practice, there is an increasing demand on the registration of CBCT with pre-operative scans, in many cases, CT scans. One of the major challenges of thoracic-abdominal CT/CBCT registration is from various fields of view (FOVs) of the two imaging modalities. The proposed approach utilizes a priori knowledge of anatomy to generate 2D anatomy targeted projection (ATP) images that surrogate the original volumes. The use of lower dimension surrogate images can significantly reduce the computation cost of similarity evaluation during optimization and make it practically feasible to perform global optimization based registration for image-guided interventional procedures. Another a priori knowledge about the local optima distribution on energy curves is further used to effectively select multi-starting points for registration optimization. 20 clinical data sets were used to validate the method and the target registration error (TRE) and maximum registration error (MRE) were calculated to compare the performance of the knowledge-driven quasi-global registration against a typical local-search based registration. The local search based registration failed on 60% cases, with an average TRE of 22.9mm and MRE of 28.1mm; the knowledge-driven quasi-global registration achieved satisfactory results for all the 20 data sets, with an average TRE of 3.5mm, and MRE of 2.6mm. The average computation time for the knowledge-driven quasi-global registration is 8.7 seconds.

  9. Thoracic cavity segmentation algorithm using multiorgan extraction and surface fitting in volumetric CT

    SciTech Connect

    Bae, JangPyo; Kim, Namkug Lee, Sang Min; Seo, Joon Beom; Kim, Hee Chan

    2014-04-15

    Purpose: To develop and validate a semiautomatic segmentation method for thoracic cavity volumetry and mediastinum fat quantification of patients with chronic obstructive pulmonary disease. Methods: The thoracic cavity region was separated by segmenting multiorgans, namely, the rib, lung, heart, and diaphragm. To encompass various lung disease-induced variations, the inner thoracic wall and diaphragm were modeled by using a three-dimensional surface-fitting method. To improve the accuracy of the diaphragm surface model, the heart and its surrounding tissue were segmented by a two-stage level set method using a shape prior. To assess the accuracy of the proposed algorithm, the algorithm results of 50 patients were compared to the manual segmentation results of two experts with more than 5 years of experience (these manual results were confirmed by an expert thoracic radiologist). The proposed method was also compared to three state-of-the-art segmentation methods. The metrics used to evaluate segmentation accuracy were volumetric overlap ratio (VOR), false positive ratio on VOR (FPRV), false negative ratio on VOR (FNRV), average symmetric absolute surface distance (ASASD), average symmetric squared surface distance (ASSSD), and maximum symmetric surface distance (MSSD). Results: In terms of thoracic cavity volumetry, the mean ± SD VOR, FPRV, and FNRV of the proposed method were (98.17 ± 0.84)%, (0.49 ± 0.23)%, and (1.34 ± 0.83)%, respectively. The ASASD, ASSSD, and MSSD for the thoracic wall were 0.28 ± 0.12, 1.28 ± 0.53, and 23.91 ± 7.64 mm, respectively. The ASASD, ASSSD, and MSSD for the diaphragm surface were 1.73 ± 0.91, 3.92 ± 1.68, and 27.80 ± 10.63 mm, respectively. The proposed method performed significantly better than the other three methods in terms of VOR, ASASD, and ASSSD. Conclusions: The proposed semiautomatic thoracic cavity segmentation method, which extracts multiple organs (namely, the rib, thoracic wall, diaphragm, and heart

  10. Improving thoracic four-dimensional cone-beam CT reconstruction with anatomical-adaptive image regularization (AAIR).

    PubMed

    Shieh, Chun-Chien; Kipritidis, John; O'Brien, Ricky T; Cooper, Benjamin J; Kuncic, Zdenka; Keall, Paul J

    2015-01-21

    Total-variation (TV) minimization reconstructions can significantly reduce noise and streaks in thoracic four-dimensional cone-beam computed tomography (4D CBCT) images compared to the Feldkamp-Davis-Kress (FDK) algorithm currently used in practice. TV minimization reconstructions are, however, prone to over-smoothing anatomical details and are also computationally inefficient. The aim of this study is to demonstrate a proof of concept that these disadvantages can be overcome by incorporating the general knowledge of the thoracic anatomy via anatomy segmentation into the reconstruction. The proposed method, referred as the anatomical-adaptive image regularization (AAIR) method, utilizes the adaptive-steepest-descent projection-onto-convex-sets (ASD-POCS) framework, but introduces an additional anatomy segmentation step in every iteration. The anatomy segmentation information is implemented in the reconstruction using a heuristic approach to adaptively suppress over-smoothing at anatomical structures of interest. The performance of AAIR depends on parameters describing the weighting of the anatomy segmentation prior and segmentation threshold values. A sensitivity study revealed that the reconstruction outcome is not sensitive to these parameters as long as they are chosen within a suitable range. AAIR was validated using a digital phantom and a patient scan and was compared to FDK, ASD-POCS and the prior image constrained compressed sensing (PICCS) method. For the phantom case, AAIR reconstruction was quantitatively shown to be the most accurate as indicated by the mean absolute difference and the structural similarity index. For the patient case, AAIR resulted in the highest signal-to-noise ratio (i.e. the lowest level of noise and streaking) and the highest contrast-to-noise ratios for the tumor and the bony anatomy (i.e. the best visibility of anatomical details). Overall, AAIR was much less prone to over-smoothing anatomical details compared to ASD-POCS and did

  11. Improving thoracic four-dimensional cone-beam CT reconstruction with anatomical-adaptive image regularization (AAIR)

    NASA Astrophysics Data System (ADS)

    Shieh, Chun-Chien; Kipritidis, John; O'Brien, Ricky T.; Cooper, Benjamin J.; Kuncic, Zdenka; Keall, Paul J.

    2015-01-01

    Total-variation (TV) minimization reconstructions can significantly reduce noise and streaks in thoracic four-dimensional cone-beam computed tomography (4D CBCT) images compared to the Feldkamp-Davis-Kress (FDK) algorithm currently used in practice. TV minimization reconstructions are, however, prone to over-smoothing anatomical details and are also computationally inefficient. The aim of this study is to demonstrate a proof of concept that these disadvantages can be overcome by incorporating the general knowledge of the thoracic anatomy via anatomy segmentation into the reconstruction. The proposed method, referred as the anatomical-adaptive image regularization (AAIR) method, utilizes the adaptive-steepest-descent projection-onto-convex-sets (ASD-POCS) framework, but introduces an additional anatomy segmentation step in every iteration. The anatomy segmentation information is implemented in the reconstruction using a heuristic approach to adaptively suppress over-smoothing at anatomical structures of interest. The performance of AAIR depends on parameters describing the weighting of the anatomy segmentation prior and segmentation threshold values. A sensitivity study revealed that the reconstruction outcome is not sensitive to these parameters as long as they are chosen within a suitable range. AAIR was validated using a digital phantom and a patient scan and was compared to FDK, ASD-POCS and the prior image constrained compressed sensing (PICCS) method. For the phantom case, AAIR reconstruction was quantitatively shown to be the most accurate as indicated by the mean absolute difference and the structural similarity index. For the patient case, AAIR resulted in the highest signal-to-noise ratio (i.e. the lowest level of noise and streaking) and the highest contrast-to-noise ratios for the tumor and the bony anatomy (i.e. the best visibility of anatomical details). Overall, AAIR was much less prone to over-smoothing anatomical details compared to ASD-POCS and did

  12. Improving thoracic four-dimensional cone-beam CT reconstruction with anatomical-adaptive image regularization (AAIR)

    PubMed Central

    Shieh, Chun-Chien; Kipritidis, John; O’Brien, Ricky T; Cooper, Benjamin J; Kuncic, Zdenka; Keall, Paul J

    2015-01-01

    Total-variation (TV) minimization reconstructions can significantly reduce noise and streaks in thoracic four-dimensional cone-beam computed tomography (4D CBCT) images compared to the Feldkamp-Davis-Kress (FDK) algorithm currently used in practice. TV minimization reconstructions are, however, prone to over-smoothing anatomical details and are also computationally inefficient. The aim of this study is to demonstrate a proof of concept that these disadvantages can be overcome by incorporating the general knowledge of the thoracic anatomy via anatomy segmentation into the reconstruction. The proposed method, referred as the anatomical-adaptive image regularization (AAIR) method, utilizes the adaptive-steepest-descent projection-onto-convex-sets (ASD-POCS) framework, but introduces an additional anatomy segmentation step in every iteration. The anatomy segmentation information is implemented in the reconstruction using a heuristic approach to adaptively suppress over-smoothing at anatomical structures of interest. The performance of AAIR depends on parameters describing the weighting of the anatomy segmentation prior and segmentation threshold values. A sensitivity study revealed that the reconstruction outcome is not sensitive to these parameters as long as they are chosen within a suitable range. AAIR was validated using a digital phantom and a patient scan, and was compared to FDK, ASD-POCS, and the prior image constrained compressed sensing (PICCS) method. For the phantom case, AAIR reconstruction was quantitatively shown to be the most accurate as indicated by the mean absolute difference and the structural similarity index. For the patient case, AAIR resulted in the highest signal-to-noise ratio (i.e. the lowest level of noise and streaking) and the highest contrast-to-noise ratios for the tumor and the bony anatomy (i.e. the best visibility of anatomical details). Overall, AAIR was much less prone to over-smoothing anatomical details compared to ASD-POCS, and

  13. Computerized lung nodule detection on thoracic CT images: combined rule-based and statistical classifier for false-positive reduction

    NASA Astrophysics Data System (ADS)

    Gurcan, Metin N.; Petrick, Nicholas; Sahiner, Berkman; Chan, Heang-Ping; Cascade, Philip N.; Kazerooni, Ella A.; Hadjiiski, Lubomir M.

    2001-07-01

    We are developing a computer-aided diagnosis (CAD) system for lung nodule detection on thoracic helical computed tomography (CT) images. In the first stage of this CAD system, lung regions are identified and suspicious structures are segmented. These structures may include true lung nodules or normal structures that consist mainly of vascular structures. We have designed rule-based classifiers to distinguish nodules and normal structures using 2D and 3D features. After rule-based classification, linear discriminant analysis (LDA) is used to further reduce the number of false positive (FP) objects. We have performed a preliminary study using CT images from 17 patients with 31 lung nodules. When only LDA classification was applied to the segmented objects, the sensitivity was 84% (26/31) with 2.53 (1549/612) FP objects per slice. When the LDA followed the rule-based classifier, the number of FP objects per slice decreased to 1.75 (1072/612) at the same sensitivity. These preliminary results demonstrate the feasibility of our approach for nodule detection and FP reduction on CT images. The inclusion of rule-based classification leads to an improvement in detection accuracy for the CAD system.

  14. Algorithm of pulmonary emphysema extraction using thoracic 3-D CT images

    NASA Astrophysics Data System (ADS)

    Saita, Shinsuke; Kubo, Mitsuru; Kawata, Yoshiki; Niki, Noboru; Nakano, Yasutaka; Ohmatsu, Hironobu; Tominaga, Keigo; Eguchi, Kenji; Moriyama, Noriyuki

    2008-03-01

    Emphysema patients have the tendency to increase due to aging and smoking. Emphysematous disease destroys alveolus and to repair is impossible, thus early detection is essential. CT value of lung tissue decreases due to the destruction of lung structure. This CT value becomes lower than the normal lung- low density absorption region or referred to as Low Attenuation Area (LAA). So far, the conventional way of extracting LAA by simple thresholding has been proposed. However, the CT value of CT image fluctuates due to the measurement conditions, with various bias components such as inspiration, expiration and congestion. It is therefore necessary to consider these bias components in the extraction of LAA. We removed these bias components and we proposed LAA extraction algorithm. This algorithm has been applied to the phantom image. Then, by using the low dose CT(normal: 30 cases, obstructive lung disease: 26 cases), we extracted early stage LAA and quantitatively analyzed lung lobes using lung structure.

  15. Evaluation of thoracic tumors with (18)F-FMT and (18)F-FDG PET-CT: a clinicopathological study.

    PubMed

    Kaira, Kyoichi; Oriuchi, Noboru; Shimizu, Kimihiro; Ishikita, Tomohiro; Higuchi, Tetsuya; Imai, Hisao; Yanagitani, Noriko; Sunaga, Noriaki; Hisada, Takeshi; Ishizuka, Tamotsu; Kanai, Yoshikatsu; Endou, Hitoshi; Nakajima, Takashi; Endo, Keigo; Mori, Masatomo

    2009-03-01

    L-[3-(18)F]-alpha-methyltyrosine ((18)F-FMT) is an aminoacid tracer for positron emission tomography (PET). The aim of this study was to determine whether PET-CT with (18)F-FMT provides additional information for the preoperative diagnostic workup as compared with (18)F-FDG PET. PET-CT studies with (18)F-FMT and (18)F-FDG were performed as a part of the preoperative workup in 36 patients with histologically confirmed bronchial carcinoma, 6 patients with benign lesions and a patient with atypical carcinoid. Expression of L-type amino acid transporter 1 (LAT1), CD98, Ki-67 labeling index, VEGF, CD31 and CD34 of the resected tumors were analyzed by immunohistochemical staining, and correlated with the uptake of PET tracers. For the detection of pulmonary malignant tumors, (18)F-FMT PET exhibited a sensitivity of 84% whereas the sensitivity for (18)F-FDG PET was 89% (p = 0.736). (18)F-FMT PET-CT and (18)F-FDG PET-CT agreed with pathological staging in 85 and 68%, respectively (p = 0.151). (18)F-FMT uptake was closely correlated with LAT1, CD98, cell proliferation and angiogenesis. The specificity of (18)F-FMT PET for diagnosing thoracic tumors was higher than that of (18)F-FDG PET. Our results suggest that coexpression of LAT1 and CD98 in addition to cell proliferation and angiogenesis is relavant for the progression and metastasis of lung cancer.

  16. Hybrid registration of PET/CT in thoracic region with pre-filtering PET sinogram

    NASA Astrophysics Data System (ADS)

    Mokri, S. S.; Saripan, M. I.; Marhaban, M. H.; Nordin, A. J.; Hashim, S.

    2015-11-01

    The integration of physiological (PET) and anatomical (CT) images in cancer delineation requires an accurate spatial registration technique. Although hybrid PET/CT scanner is used to co-register these images, significant misregistrations exist due to patient and respiratory/cardiac motions. This paper proposes a hybrid feature-intensity based registration technique for hybrid PET/CT scanner. First, simulated PET sinogram was filtered with a 3D hybrid mean-median before reconstructing the image. The features were then derived from the segmented structures (lung, heart and tumor) from both images. The registration was performed based on modified multi-modality demon registration with multiresolution scheme. Apart from visual observations improvements, the proposed registration technique increased the normalized mutual information index (NMI) between the PET/CT images after registration. All nine tested datasets show marked improvements in mutual information (MI) index than free form deformation (FFD) registration technique with the highest MI increase is 25%.

  17. Low kV settings CT angiography (CTA) with low dose contrast medium volume protocol in the assessment of thoracic and abdominal aorta disease: a feasibility study

    PubMed Central

    Talei Franzesi, C; Fior, D; Bonaffini, P A; Minutolo, O; Sironi, S

    2015-01-01

    Objective: To assess the diagnostic quality of low dose (100 kV) CT angiography (CTA), by using ultra-low contrast medium volume (30 ml), for thoracic and abdominal aorta evaluation. Methods: 67 patients with thoracic or abdominal vascular disease underwent multidetector CT study using a 256 slice scanner, with low dose radiation protocol (automated tube current modulation, 100 kV) and low contrast medium volume (30 ml; 4 ml s−1). Density measurements were performed on ascending, arch, descending thoracic aorta, anonymous branch, abdominal aorta, and renal and common iliac arteries. Radiation dose exposure [dose–length product (DLP)] was calculated. A control group of 35 patients with thoracic or abdominal vascular disease were evaluated with standard CTA protocol (automated tube current modulation, 120 kV; contrast medium, 80 ml). Results: In all patients, we correctly visualized and evaluated main branches of the thoracic and abdominal aorta. No difference in density measurements was achieved between low tube voltage protocol (mean attenuation value of thoracic aorta, 304 HU; abdominal, 343 HU; renal arteries, 331 HU) and control group (mean attenuation value of thoracic aorta, 320 HU; abdominal, 339; renal arteries, 303 HU). Radiation dose exposure in low tube voltage protocol was significantly different between thoracic and abdominal low tube voltage studies (490 and 324 DLP, respectively) and the control group (thoracic DLP, 1032; abdomen, DLP 1078). Conclusion: Low-tube-voltage protocol may provide a diagnostic performance comparable with that of the standard protocol, decreasing radiation dose exposure and contrast material volume amount. Advances in knowledge: Low-tube-voltage-setting protocol combined with ultra-low contrast agent volume (30 ml), by using new multidetector-row CT scanners, represents a feasible diagnostic tool to significantly reduce the radiation dose delivered to patients and to preserve renal function

  18. A novel spherical shell filter for reducing false positives in automatic detection of pulmonary nodules in thoracic CT scans

    NASA Astrophysics Data System (ADS)

    van de Leemput, Sil; Dorssers, Frank; Ehteshami Bejnordi, Babak

    2015-03-01

    Early detection of pulmonary nodules is crucial for improving prognosis of patients with lung cancer. Computer-aided detection of lung nodules in thoracic computed tomography (CT) scans has a great potential to enhance the performance of the radiologist in detecting nodules. In this paper we present a computer-aided lung nodule detection system for computed tomography (CT) scans that works in three steps. The system first segments the lung using thresholding and hole filling. From this segmentation the system extracts candidate nodules using Laplacian of Gaussian. To reject false positives among the detected candidate nodules, multiple established features are calculated. We propose a novel feature based on a spherical shell filter, which is specifically designed to distinguish between vascular structures and nodular structures. The performance of the proposed CAD system was evaluated by partaking in the ANODE09 challenge, which presents a platform for comparing automatic nodule detection programs. The results from the challenge show that our CAD system ranks third among the submitted works, demonstrating the efficacy of our proposed CAD system. The results also show that our proposed spherical shell filter in combination with conventional features can significantly reduce the number of false positives from the detected candidate nodules.

  19. Fuzzy Clustering Applied to ROI Detection in Helical Thoracic CT Scans with a New Proposal and Variants.

    PubMed

    Castro, Alfonso; Rey, Alberto; Boveda, Carmen; Arcay, Bernardino; Sanjurjo, Pedro

    2016-01-01

    The detection of pulmonary nodules is one of the most studied problems in the field of medical image analysis due to the great difficulty in the early detection of such nodules and their social impact. The traditional approach involves the development of a multistage CAD system capable of informing the radiologist of the presence or absence of nodules. One stage in such systems is the detection of ROI (regions of interest) that may be nodules in order to reduce the space of the problem. This paper evaluates fuzzy clustering algorithms that employ different classification strategies to achieve this goal. After characterising these algorithms, the authors propose a new algorithm and different variations to improve the results obtained initially. Finally it is shown as the most recent developments in fuzzy clustering are able to detect regions that may be nodules in CT studies. The algorithms were evaluated using helical thoracic CT scans obtained from the database of the LIDC (Lung Image Database Consortium). PMID:27517049

  20. Fuzzy Clustering Applied to ROI Detection in Helical Thoracic CT Scans with a New Proposal and Variants

    PubMed Central

    Castro, Alfonso; Boveda, Carmen; Arcay, Bernardino; Sanjurjo, Pedro

    2016-01-01

    The detection of pulmonary nodules is one of the most studied problems in the field of medical image analysis due to the great difficulty in the early detection of such nodules and their social impact. The traditional approach involves the development of a multistage CAD system capable of informing the radiologist of the presence or absence of nodules. One stage in such systems is the detection of ROI (regions of interest) that may be nodules in order to reduce the space of the problem. This paper evaluates fuzzy clustering algorithms that employ different classification strategies to achieve this goal. After characterising these algorithms, the authors propose a new algorithm and different variations to improve the results obtained initially. Finally it is shown as the most recent developments in fuzzy clustering are able to detect regions that may be nodules in CT studies. The algorithms were evaluated using helical thoracic CT scans obtained from the database of the LIDC (Lung Image Database Consortium). PMID:27517049

  1. [Update: standardized CT/HRCT classification of occupational and environmental thoracic diseases in Germany].

    PubMed

    Hering, K G; Hofmann-Preiß, K; Kraus, T

    2014-04-01

    The high-resolution computed tomography (HRCT) coding scheme of the international classification of occupational and environmental respiratory diseases (ICOERD) presented here is an instrument for a standardized semiquantitative description of occupation and environment-linked as well as other pulmonary and pleural diseases. Analogous to the International Labour Organization (ILO) classification, the ICOERD coding scheme should always be used when the CT/HRCT examination is employed for occupational medical investigations or expert opinions. After publication of the guidelines and recommendations on diagnostics and expert assessment of asbestos-linked diseases and silicosis, the application of a standardized investigation program and assessment with the ICOERD classification form are obligatory, at least for the initial assessment. Furthermore, its use in the field of follow-up assessments of occupational diseases should be encouraged in order to guarantee comparability between individual reports (interreader variability) and at least a semiquantitative assessment of disease progression in isolated cases. Because the anatomical structures in projection radiography and CT are not presented identically, a 1:1 transfer of the results of the ILO classification to the CT/HRCT coding scheme is not possible. An overview image of the thorax does not allow overlap-free reproduction of structures, in contrast to CT. These methodological differences can in cases of isolated assessment result in different opinions of projection and CT images mostly by different investigators. In cases of discrepant opinions an integrated report of findings by combination of all information from both procedures is necessary. PMID:24737105

  2. TU-F-BRF-07: Accuracy of Routine Treatment Planning 4D and DIBH CT Delineation of the Left Anterior Descending Artery in Radiotherapy

    SciTech Connect

    White, B; Lin, L; Freedmen, G; Both, S; Vennarini, S

    2014-06-15

    Purpose: To assess the feasibility of routine treatment planning 4DCT and deep inspiration breath-hold (DIBH) to accurately contour the left anterior descending artery (LAD), a primary indicator of cardiac toxicity, for radiotherapy treatment planning of breast cancer. Methods: Ten subjects were imaged with a cardiac-gated MRI protocol to determine the displacement of a ROI that included the LAD. The subjects performed a series of breath-hold maneuvers to obtain short-axis and radial views, which were resampled to create a 3D-volume. Tissue motion was determined using a multi-resolution 3D optical flow deformable image registration algorithm. The ROI motion was then used as a spatial boundary to characterize the blurring motion of the LAD in ten patients during clinical 4DCT and DIBH protocols. A radiologist contoured the LAD. Coronary motion-induced blurring artifacts were quantified by applying an unsharp filter to accentuate the LAD despite motion-blurring. The 4DCT maximum inhalation and exhalation respiratory phases were co-registered to determine the LAD displacement during tidal respiration, as visualized in 4DCT. Results: The average 90{sup th} percentile heart motion for the ROI was 0.7±0.1mm(LR), 1.3±0.6mm(SI), 0.6±0.2mm(AP) in the cardiac-gated MRI cohort. The average relative increase in the number of voxels comprising the LAD contour was 69.4±4.5% for the DIBH. During tidal respiration, the average relative increase in the LAD contour was 69.3±5.9% and 67.9±4.6% for inhalation and exhalation respiratory phases respectively. The average 90{sup th} percentile LAD motion was 4.8±1.1mm(LR), 0.9±0.4mm(SI), 1.9±0.6mm(AP) for the 4DCT cohort, in the absence of cardiac-gating. Conclusion: Uncompensated coronary motion was the dominant form of motion blurring present in the CT images due to the high frequency of the cardiac cycle relative to the respiratory cycle. The 4D and DIBH CT contour delineation of the LAD was consistently overestimated without

  3. Deformable registration of the inflated and deflated lung for cone-beam CT-guided thoracic surgery

    NASA Astrophysics Data System (ADS)

    Uneri, Ali; Nithiananthan, Sajendra; Schafer, Sebastian; Otake, Yoshito; Stayman, J. Webster; Kleinszig, Gerhard; Sussman, Marc S.; Taylor, Russell H.; Prince, Jerry L.; Siewerdsen, Jeffrey H.

    2012-02-01

    Intraoperative cone-beam CT (CBCT) could offer an important advance to thoracic surgeons in directly localizing subpalpable nodules during surgery. An image-guidance system is under development using mobile C-arm CBCT to directly localize tumors in the OR, potentially reducing the cost and logistical burden of conventional preoperative localization and facilitating safer surgery by visualizing critical structures surrounding the surgical target (e.g., pulmonary artery, airways, etc.). To utilize the wealth of preoperative image/planning data and to guide targeting under conditions in which the tumor may not be directly visualized, a deformable registration approach has been developed that geometrically resolves images of the inflated (i.e., inhale or exhale) and deflated states of the lung. This novel technique employs a coarse model-driven approach using lung surface and bronchial airways for fast registration, followed by an image-driven registration using a variant of the Demons algorithm to improve target localization to within ~1 mm. Two approaches to model-driven registration are presented and compared - the first involving point correspondences on the surface of the deflated and inflated lung and the second a mesh evolution approach. Intensity variations (i.e., higher image intensity in the deflated lung) due to expulsion of air from the lungs are accounted for using an a priori lung density modification, and its improvement on the performance of the intensity-driven Demons algorithm is demonstrated. Preliminary results of the combined model-driven and intensity-driven registration process demonstrate accuracy consistent with requirements in minimally invasive thoracic surgery in both target localization and critical structure avoidance.

  4. Automatic thoracic anatomy segmentation on CT images using hierarchical fuzzy models and registration

    NASA Astrophysics Data System (ADS)

    Sun, Kaioqiong; Udupa, Jayaram K.; Odhner, Dewey; Tong, Yubing; Torigian, Drew A.

    2014-03-01

    This paper proposes a thoracic anatomy segmentation method based on hierarchical recognition and delineation guided by a built fuzzy model. Labeled binary samples for each organ are registered and aligned into a 3D fuzzy set representing the fuzzy shape model for the organ. The gray intensity distributions of the corresponding regions of the organ in the original image are recorded in the model. The hierarchical relation and mean location relation between different organs are also captured in the model. Following the hierarchical structure and location relation, the fuzzy shape model of different organs is registered to the given target image to achieve object recognition. A fuzzy connected delineation method is then used to obtain the final segmentation result of organs with seed points provided by recognition. The hierarchical structure and location relation integrated in the model provide the initial parameters for registration and make the recognition efficient and robust. The 3D fuzzy model combined with hierarchical affine registration ensures that accurate recognition can be obtained for both non-sparse and sparse organs. The results on real images are presented and shown to be better than a recently reported fuzzy model-based anatomy recognition strategy.

  5. Multi-detector thoracic CT findings in cerebro-costo-mandibular syndrome: rib gaps and failure of costo-vertebral separation.

    PubMed

    Watson, Tom Anthony; Arthurs, Owen John; Muthialu, Nagarajan; Calder, Alistair Duncan

    2014-02-01

    Cerebro-costo-mandibular syndrome (CCMS) describes a triad of mandibular hypoplasia, brain dysfunction and posterior rib defects ("rib gaps"). We present the CT imaging for a 2-year-old girl with CCMS that highlights the rib gap defects and shows absent transverse processes with abnormal fusion of the ribs directly to the vertebral bodies. We argue that this is likely to relate to abnormal lateral sclerotome development in embryology, with the failure of normal costo-vertebral junctions compounding impaired thoracic function. The case also highlights the use of CT for specific indications in skeletal dysplasia.

  6. SU-D-207-01: Markerless Respiratory Motion Tracking with Contrast Enhanced Thoracic Cone Beam CT Projections

    SciTech Connect

    Chao, M; Yuan, Y; Rosenzweig, K; Lo, Y; Brousmiche, S

    2015-06-15

    Purpose: To develop a novel technique to enhance the image contrast of clinical cone beam CT projections and extract respiratory signals based on anatomical motion using the modified Amsterdam Shroud (AS) method to benefit image guided radiation therapy. Methods: Thoracic cone beam CT projections acquired prior to treatment were preprocessed to increase their contrast for better respiratory signal extraction. Air intensity on raw images was firstly estimated and then applied to correct the projections to generate new attenuation images that were subsequently improved with deeper anatomy feature enhancement through taking logarithm operation, derivative along superior-inferior direction, respectively. All pixels on individual post-processed two dimensional images were horizontally summed to one column and all projections were combined side by side to create an AS image from which patient’s respiratory signal was extracted. The impact of gantry rotation on the breathing signal rendering was also investigated. Ten projection image sets from five lung cancer patients acquired with the Varian Onboard Imager on 21iX Clinac (Varian Medical Systems, Palo Alto, CA) were employed to assess the proposed technique. Results: Application of the air correction on raw projections showed that more than an order of magnitude of contrast enhancement was achievable. The typical contrast on the raw projections is around 0.02 while that on attenuation images could greater than 0.5. Clear and stable breathing signal can be reliably extracted from the new images while the uncorrected projection sets failed to yield clear signals most of the time. Conclusion: Anatomy feature plays a key role in yielding breathing signal from the projection images using the AS technique. The air correction process facilitated the contrast enhancement significantly and attenuation images thus obtained provides a practical solution to obtaining markerless breathing motion tracking.

  7. Mediastinal lymph node detection on thoracic CT scans using spatial prior from multi-atlas label fusion

    NASA Astrophysics Data System (ADS)

    Liu, Jiamin; Zhao, Jocelyn; Hoffman, Joanne; Yao, Jianhua; Zhang, Weidong; Turkbey, Evrim B.; Wang, Shijun; Kim, Christine; Summers, Ronald M.

    2014-03-01

    Lymph nodes play an important role in clinical practice but detection is challenging due to low contrast surrounding structures and variable size and shape. We propose a fully automatic method for mediastinal lymph node detection on thoracic CT scans. First, lungs are automatically segmented to locate the mediastinum region. Shape features by Hessian analysis, local scale, and circular transformation are computed at each voxel. Spatial prior distribution is determined based on the identification of multiple anatomical structures (esophagus, aortic arch, heart, etc.) by using multi-atlas label fusion. Shape features and spatial prior are then integrated for lymph node detection. The detected candidates are segmented by curve evolution. Characteristic features are calculated on the segmented lymph nodes and support vector machine is utilized for classification and false positive reduction. We applied our method to 20 patients with 62 enlarged mediastinal lymph nodes. The system achieved a significant improvement with 80% sensitivity at 8 false positives per patient with spatial prior compared to 45% sensitivity at 8 false positives per patient without a spatial prior.

  8. TH-E-17A-09: High Quality and Artifact-Free 4D Cone Beam CT and Its Application in Adaptive Treatment Planning

    SciTech Connect

    Niu, K; Li, K; Smilowitz, J; Chen, G

    2014-06-15

    Purpose: To develop a high quality 4D cone beam CT (4DCBCT) method that is immune to patient/couch truncations and to investigate its application in adaptive replanning of lung XRT. Methods: In this study, IRB-approved human subject CBCT data was acquired using a Varian on-board imager with 1 minute rotation time. The acquired projection data was retrospectively sorted into 20 respiratory phase bins, from which 4DCBCT images with high SNR and high temporal resolution were generated using Prior Image Constrained Compressed Sensing (PICCS). Couch and patient truncations generate strong data inconsistency in the projection data and artifacts in the 4DCBCT image. They were addressed using an adaptive PICCS method. The artifact-free PICCS-4DCBCT images were used to generate adaptive treatment plans for the same patient at the 10th (day 21) and 30th (day 47) fractions. Dosimetric impacts with and without PICCS- 4DCBCT were evaluated by isodose distributions, DVHs, and other dosimetric factors. Results: The adaptive PICCS-4DCBCT method improves image quality by removing residue truncation artifacts; measured universal image quality increased 37%. The isodose lines and DVHs with PICCS-4DCBCT-based adaptive replanning were significantly more conformal to PTV than without replanning due to changes in patient anatomy caused by progress of the treatment. The mean dose to PTV at the 10th fraction was 63.1Gy with replanning and 64.2Gy without replanning, where the prescribed dose was 60Gy, in 2Gy × 30 fractions. The mean dose to PTV at the 30th fraction was 61.6Gy with replanning and 64.9Gy without replanning. Lung V20 was 37.1%, 41.9% and 43.3% for original plan, 10th fraction plan and 30th fraction plan; with re-planning, Lung V20 was 37.1%, 32%, 27.8%. Conclusion: 4DCBCT imaging using adaptive PICCS is able to generate high quality, artifact-free images that potentially can be used to create replanning for improving radiotherapy of the lung. K Niu, K Li, J Smilowitz: Nothing

  9. Tracking 'differential organ motion' with a 'breathing' multileaf collimator: magnitude of problem assessed using 4D CT data and a motion-compensation strategy

    NASA Astrophysics Data System (ADS)

    McClelland, J. R.; Webb, S.; McQuaid, D.; Binnie, D. M.; Hawkes, D. J.

    2007-08-01

    Intrafraction tumour (e.g. lung) motion due to breathing can, in principle, be compensated for by applying identical breathing motions to the leaves of a multileaf collimator (MLC) as intensity-modulated radiation therapy is delivered by the dynamic MLC (DMLC) technique. A difficulty arising, however, is that irradiated voxels, which are in line with a bixel at one breathing phase (at which the treatment plan has been made), may move such that they cease to be in line with that breathing bixel at another phase. This is the phenomenon of differential voxel motion and existing tracking solutions have ignored this very real problem. There is absolutely no tracking solution to the problem of compensating for differential voxel motion. However, there is a strategy that can be applied in which the leaf breathing is determined to minimize the geometrical mismatch in a least-squares sense in irradiating differentially-moving voxels. A 1D formulation in very restricted circumstances is already in the literature and has been applied to some model breathing situations which can be studied analytically. These are, however, highly artificial. This paper presents the general 2D formulation of the problem including allowing different importance factors to be applied to planning target volume and organ at risk (or most generally) each voxel. The strategy also extends the literature strategy to the situation where the number of voxels connecting to a bixel is a variable. Additionally the phenomenon of 'cross-leaf-track/channel' voxel motion is formally addressed. The general equations are presented and analytic results are given for some 1D, artificially contrived, motions based on the Lujan equations of breathing motion. Further to this, 3D clinical voxel motion data have been extracted from 4D CT measurements to both assess the magnitude of the problem of 2D motion perpendicular to the beam-delivery axis in clinical practice and also to find the 2D optimum breathing-leaf strategy

  10. Thoracic dual energy CT: acquisition protocols, current applications and future developments.

    PubMed

    Ohana, M; Jeung, M Y; Labani, A; El Ghannudi, S; Roy, C

    2014-11-01

    Thanks to a simultaneous acquisition at high and low kilovoltage, dual energy computed tomography (DECT) can achieve material-based decomposition (iodine, water, calcium, etc.) and reconstruct images at different energy levels (40 to 140keV). Post-processing uses this potential to maximise iodine detection, which elicits demonstrated added value for chest imaging in acute and chronic embolic diseases (increases the quality of the examination and identifies perfusion defects), follow-up of aortic endografts and detection of contrast uptake in oncology. In CT angiography, these unique features are taken advantage of to reduce the iodine load by more than half. This review article aims to set out the physical basis for the technology, the acquisition and post-processing protocols used, its proven advantages in chest pathologies, and to present future developments.

  11. Comparison of demons deformable registration-based methods for texture analysis of serial thoracic CT scans

    NASA Astrophysics Data System (ADS)

    Cunliffe, Alexandra R.; Al-Hallaq, Hania A.; Fei, Xianhan M.; Tuohy, Rachel E.; Armato, Samuel G.

    2013-02-01

    To determine how 19 image texture features may be altered by three image registration methods, "normal" baseline and follow-up computed tomography (CT) scans from 27 patients were analyzed. Nineteen texture feature values were calculated in over 1,000 32x32-pixel regions of interest (ROIs) randomly placed in each baseline scan. All three methods used demons registration to map baseline scan ROIs to anatomically matched locations in the corresponding transformed follow-up scan. For the first method, the follow-up scan transformation was subsampled to achieve a voxel size identical to that of the baseline scan. For the second method, the follow-up scan was transformed through affine registration to achieve global alignment with the baseline scan. For the third method, the follow-up scan was directly deformed to the baseline scan using demons deformable registration. Feature values in matched ROIs were compared using Bland- Altman 95% limits of agreement. For each feature, the range spanned by the 95% limits was normalized to the mean feature value to obtain the normalized range of agreement, nRoA. Wilcoxon signed-rank tests were used to compare nRoA values across features for the three methods. Significance for individual tests was adjusted using the Bonferroni method. nRoA was significantly smaller for affine-registered scans than for the resampled scans (p=0.003), indicating lower feature value variability between baseline and follow-up scan ROIs using this method. For both of these methods, however, nRoA was significantly higher than when feature values were calculated directly on demons-deformed followup scans (p<0.001). Across features and methods, nRoA values remained below 26%.

  12. AB021. Validation of real-world, non-research thoracic CT scans for quantitative analysis of COPD

    PubMed Central

    Dandurand, Ronald J.; Dandurand, Myriam; San José Estépar, Raúl; Bourbeau, Jean; Eidelman, David H.

    2016-01-01

    Background Quantitative CT (QCT) imaging plays an important role in phenotyping COPD and uses the voxel density histogram to measure total lung volume (TLV) and emphysema surrogates: low attenuation area (LAA) and lung density (LD). LD is often volume corrected using the predicted total lung capacity (TLC) to compensate for submaximal inspiration prior to image acquisition. QCT is carried out with careful attention to quality control including scanner make/model, calibration frequency, lung volume, acquisition protocol, and the use of contrast, and bears a financial and radiation cost. We wished to determine if: (I) thoracic CT scans acquired for clinical indications on a variety of scanners from different centres with varying calibration frequency, acquisition protocols and only simple breath holding instructions could yield reproducible data; (II) volume correcting LAA and LD using the pulmonary function test (PFT) measured TLC would compensate for submaximal inspiration better than using the predicted TLC; and (III) contrast infusion causes predictable changes in the QCT metrics TLV, LAA and LD. Methods A total of 82 subjects (67 COPD, 15 non-COPD) from a community respirology practice had at least 2 CT scans judged free of significant infiltrates, performed on 10 different models of scanner in 7 different community hospitals or radiology centres for clinical indications within a 13-month period and had pulmonary function tests performed respecting ATS criteria within 14 months of at least 1 CT scan. Images were analysed with Airway Inspector in ITALIC FONT (airwayinspector.acil-bwh.org) for LAA [<-950 Hounsfield Unit (HU)], LD (at 15th percentile + 1,000 HU) and TLV. 46 paired non-contrast scans (NC/NC) and 42 paired contrast/non-contrast scans (C/NC, 23 CT angio with early infusion, 19 routine contrast with late infusion) were used to construct identity plots for TLV, LAA, LD, and LAA and LD corrected for both predicted TLC and PFT measured TLC. LAA was volume

  13. Computational blood flow and vessel wall modeling in a CT-based thoracic aorta after stent-graft implantation

    NASA Astrophysics Data System (ADS)

    Hazer, Dilana; Stoll, Markus; Schmidt, Eduard; Richter, Goetz-M.; Dillmann, Rüdiger

    2010-03-01

    Abnormal blood flow conditions and structural fatigue within stented vessels may lead to undesired failure causing death to the patient. Image-based computational modeling provides a physical and realistic insight into the patientspecific biomechanics and enables accurate predictive simulations of development, growth and failure of cardiovascular diseases as well as associated risks. Controlling the efficiency of an endovascular treatment is necessary for the evaluation of potential complications and predictions on the assessment of the pathological state. In this paper we investigate the effects of stent-graft implantation on the biomechanics in a patient-specific thoracic aortic model. The patient geometry and the implanted stent-graft are obtained from morphological data based on a CT scan performed during a controlling routine. Computational fluid dynamics (CFD) and computational structure mechanics (CSM) simulations are conducted based on the finite volume method (FVM) and on the finite element method (FEM) to compute the hemodynamics and the elastomechanics within the aortic model, respectively. Physiological data based on transient pressure and velocity profiles are used to set the necessary boundary conditions. Further, the effects of various boundary conditions and definition of contact interactions on the numerical stability of the blood flow and the vessel wall simulation results are also investigated. The quantification of the hemodynamics and the elastomechanics post endovascular intervention provides a realistic controlling of the state of the stented vessel and of the efficiency of the therapy. Consequently, computational modeling would help in evaluating individual therapies and optimal treatment strategies in the field of minimally invasive endovascular surgery.

  14. Quality Assurance of 4D-CT Scan Techniques in Multicenter Phase III Trial of Surgery Versus Stereotactic Radiotherapy (Radiosurgery or Surgery for Operable Early Stage (Stage 1A) Non-Small-Cell Lung Cancer [ROSEL] Study)

    SciTech Connect

    Hurkmans, Coen W.; Lieshout, Maarten van; Schuring, Danny; Heumen, Marielle J.T. van; Cuijpers, Johan P.; Lagerwaard, Frank J.; Widder, Joachim; Heide, Uulke A. van der; Senan, Suresh

    2011-07-01

    Purpose: To determine the accuracy of four-dimensional computed tomography (4D-CT) scanning techniques in institutions participating in a Phase III trial of surgery vs. stereotactic radiotherapy (SBRT) for lung cancer. Methods and Materials: All 9 centers performed a 4D-CT scan of a motion phantom (Quasar, Modus Medical Devices) in accordance with their in-house imaging protocol for SBRT. A cylindrical cedar wood insert with plastic spheres of 15 mm (o15) and 30 mm (o30) diameter was moved in a cosine-based pattern, with an extended period in the exhale position to mimic the actual breathing motion. A range of motion of R = 15 and R = 25 mm and breathing period of T = 3 and T = 6 s were used. Positional and volumetric imaging accuracy was analyzed using Pinnacle version 8.1x at various breathing phases, including the mid-ventilation phase and maximal intensity projections of the spheres. Results: Imaging using eight CT scanners (Philips, Siemens, GE) and one positron emission tomography-CT scanner (Institution 3, Siemens) was investigated. The imaging protocols varied widely among the institutions. No strong correlation was found between the specific scan protocol parameters and the observed results. Deviations in the maximal intensity projection volumes averaged 1.9% (starting phase of the breathing cycle [o]15, R = 15), 12.3% (o15, R = 25), and -0.9% (o30, R = 15). The end-expiration volume deviations (13.4%, o15 and 2.5%, o30), were, on average, smaller than the end-inspiration deviations (20.7%, o15 and 4.5%, o30), which, in turn, were smaller than the mid-ventilation deviations (32.6%, o15 and 8.0%, o30). A slightly larger variation in the mid-ventilation origin position was observed (mean, -0.2 mm; range, -3.6-4.2) than in the maximal intensity projection origin position (mean, -0.1 mm; range, -2.5-2.5). The range of motion was generally underestimated (mean, -1.5 mm; range, -5.5-1). Conclusions: Notable differences were seen in the 4D-CT imaging protocols

  15. SU-E-J-123: Assessing Segmentation Accuracy of Internal Volumes and Sub-Volumes in 4D PET/CT of Lung Tumors Using a Novel 3D Printed Phantom

    SciTech Connect

    Soultan, D; Murphy, J; James, C; Hoh, C; Moiseenko, V; Cervino, L; Gill, B

    2015-06-15

    Purpose: To assess the accuracy of internal target volume (ITV) segmentation of lung tumors for treatment planning of simultaneous integrated boost (SIB) radiotherapy as seen in 4D PET/CT images, using a novel 3D-printed phantom. Methods: The insert mimics high PET tracer uptake in the core and 50% uptake in the periphery, by using a porous design at the periphery. A lung phantom with the insert was placed on a programmable moving platform. Seven breathing waveforms of ideal and patient-specific respiratory motion patterns were fed to the platform, and 4D PET/CT scans were acquired of each of them. CT images were binned into 10 phases, and PET images were binned into 5 phases following the clinical protocol. Two scenarios were investigated for segmentation: a gate 30–70 window, and no gating. The radiation oncologist contoured the outer ITV of the porous insert with on CT images, while the internal void volume with 100% uptake was contoured on PET images for being indistinguishable from the outer volume in CT images. Segmented ITVs were compared to the expected volumes based on known target size and motion. Results: 3 ideal breathing patterns, 2 regular-breathing patient waveforms, and 2 irregular-breathing patient waveforms were used for this study. 18F-FDG was used as the PET tracer. The segmented ITVs from CT closely matched the expected motion for both no gating and gate 30–70 window, with disagreement of contoured ITV with respect to the expected volume not exceeding 13%. PET contours were seen to overestimate volumes in all the cases, up to more than 40%. Conclusion: 4DPET images of a novel 3D printed phantom designed to mimic different uptake values were obtained. 4DPET contours overestimated ITV volumes in all cases, while 4DCT contours matched expected ITV volume values. Investigation of the cause and effects of the discrepancies is undergoing.

  16. Uniportal video-assisted thoracic surgery resection of small ground-glass opacities (GGOs) localized with CT-guided placement of microcoils and palpation

    PubMed Central

    Shi, Zhe; Jiang, Sen; Jiang, Gening

    2016-01-01

    Although uniportal video-assisted thoracic surgery (VATS) is becoming more popular, it’s still very challenging to conduct a wedge resection of small pulmonary ground-glass opacities (GGOs), especially deeply situated subpleural GGOs, via uniportal VATS. We successfully performed thirteen uniportal VATS wedge resections through an approach that combines radiologically guided microcoil localization with palpation, and we encountered no complications related to the new approach. Based on our experience, a combination of CT-guided microcoil localization with palpation in uniportal VATS for deeply situated subpleural GGOs is a safe and effective procedure for accurate diag¬nosis and resection of indeterminate GGOs. PMID:27499978

  17. Thoracic spine CT scan

    MedlinePlus

    ... helps certain areas show up better on the x-rays. Contrast can be given in several ways. It may be given as an injection through: A vein (IV) in your hand or forearm. Your back into the space surrounding the spinal cord. If contrast is used, ...

  18. Accuracy and Utility of Deformable Image Registration in {sup 68}Ga 4D PET/CT Assessment of Pulmonary Perfusion Changes During and After Lung Radiation Therapy

    SciTech Connect

    Hardcastle, Nicholas; Hofman, Michael S.; Hicks, Rodney J.; Callahan, Jason; Kron, Tomas; MacManus, Michael P.; Ball, David L.; Jackson, Price; Siva, Shankar

    2015-09-01

    Purpose: Measuring changes in lung perfusion resulting from radiation therapy dose requires registration of the functional imaging to the radiation therapy treatment planning scan. This study investigates registration accuracy and utility for positron emission tomography (PET)/computed tomography (CT) perfusion imaging in radiation therapy for non–small cell lung cancer. Methods: {sup 68}Ga 4-dimensional PET/CT ventilation-perfusion imaging was performed before, during, and after radiation therapy for 5 patients. Rigid registration and deformable image registration (DIR) using B-splines and Demons algorithms was performed with the CT data to obtain a deformation map between the functional images and planning CT. Contour propagation accuracy and correspondence of anatomic features were used to assess registration accuracy. Wilcoxon signed-rank test was used to determine statistical significance. Changes in lung perfusion resulting from radiation therapy dose were calculated for each registration method for each patient and averaged over all patients. Results: With B-splines/Demons DIR, median distance to agreement between lung contours reduced modestly by 0.9/1.1 mm, 1.3/1.6 mm, and 1.3/1.6 mm for pretreatment, midtreatment, and posttreatment (P<.01 for all), and median Dice score between lung contours improved by 0.04/0.04, 0.05/0.05, and 0.05/0.05 for pretreatment, midtreatment, and posttreatment (P<.001 for all). Distance between anatomic features reduced with DIR by median 2.5 mm and 2.8 for pretreatment and midtreatment time points, respectively (P=.001) and 1.4 mm for posttreatment (P>.2). Poorer posttreatment results were likely caused by posttreatment pneumonitis and tumor regression. Up to 80% standardized uptake value loss in perfusion scans was observed. There was limited change in the loss in lung perfusion between registration methods; however, Demons resulted in larger interpatient variation compared with rigid and B-splines registration

  19. Evaluation of various deformable image registration algorithms for thoracic images.

    PubMed

    Kadoya, Noriyuki; Fujita, Yukio; Katsuta, Yoshiyuki; Dobashi, Suguru; Takeda, Ken; Kishi, Kazuma; Kubozono, Masaki; Umezawa, Rei; Sugawara, Toshiyuki; Matsushita, Haruo; Jingu, Keiichi

    2014-01-01

    We evaluated the accuracy of one commercially available and three publicly available deformable image registration (DIR) algorithms for thoracic four-dimensional (4D) computed tomography (CT) images. Five patients with esophagus cancer were studied. Datasets of the five patients were provided by DIR-lab (dir-lab.com) and consisted of thoracic 4D CT images and a coordinate list of anatomical landmarks that had been manually identified. Expert landmark correspondence was used for evaluating DIR spatial accuracy. First, the manually measured displacement vector field (mDVF) was obtained from the coordinate list of anatomical landmarks. Then the automatically calculated displacement vector field (aDVF) was calculated by using the following four DIR algorithms: B-spine implemented in Velocity AI (Velocity Medical, Atlanta, GA, USA), free-form deformation (FFD), Horn-Schunk optical flow (OF) and Demons in DIRART of MATLAB software. Registration error is defined as the difference between mDVF and aDVF. The mean 3D registration errors were 2.7 ± 0.8 mm for B-spline, 3.6 ± 1.0 mm for FFD, 2.4 ± 0.9 mm for OF and 2.4 ± 1.2 mm for Demons. The results showed that reasonable accuracy was achieved in B-spline, OF and Demons, and that these algorithms have the potential to be used for 4D dose calculation, automatic image segmentation and 4D CT ventilation imaging in patients with thoracic cancer. However, for all algorithms, the accuracy might be improved by using the optimized parameter setting. Furthermore, for B-spline in Velocity AI, the 3D registration error was small with displacements of less than ∼10 mm, indicating that this software may be useful in this range of displacements. PMID:23869025

  20. Thoracic radiculopathy.

    PubMed

    O'Connor, Ryan C; Andary, Michael T; Russo, Randolph B; DeLano, Mark

    2002-08-01

    Thoracic radiculopathy represents an uncommon spinal disorder that is frequently overlooked in the evaluation of spinal pain syndromes. Degenerative disc disease and diabetes mellitus may frequently cause radiculopathy at the thoracic level. Electromyography and magnetic resonance imaging are useful in the evaluation of radiculopathy and thoracic spinal pain syndromes. Percutaneous vertebroplasty is a procedure that may be used in the treatment of thoracic spinal pain syndromes. Surgical intervention for thoracic radiculopathy usually is reserved for patients with progressive myelopathy and neurologic compromise.

  1. Evaluation of the cone beam CT for internal target volume localization in lung stereotactic radiotherapy in comparison with 4D MIP images

    SciTech Connect

    Wang, Lu; Chen, Xiaoming; Lin, Mu-Han; Lin, Teh; Fan, Jiajin; Jin, Lihui; Ma, Charlie M.; Xue, Jun

    2013-11-15

    Purpose: To investigate whether the three-dimensional cone-beam CT (CBCT) is clinically equivalent to the four-dimensional computed tomography (4DCT) maximum intensity projection (MIP) reconstructed images for internal target volume (ITV) localization in image-guided lung stereotactic radiotherapy.Methods: A ball-shaped polystyrene phantom with built-in cube, sphere, and cone of known volumes was attached to a motor-driven platform, which simulates a sinusoidal movement with changeable motion amplitude and frequency. Target motion was simulated in the patient in a superior-inferior (S-I) direction with three motion periods and 2 cm peak-to-peak amplitudes. The Varian onboard Exact-Arms kV CBCT system and the GE LightSpeed four-slice CT integrated with the respiratory-position-management 4DCT scanner were used to scan the moving phantom. MIP images were generated from the 4DCT images. The clinical equivalence of the two sets of images was evaluated by comparing the extreme locations of the moving objects along the motion direction, the centroid position of the ITV, and the ITV volumes that were contoured automatically by Velocity or calculated with an imaging gradient method. The authors compared the ITV volumes determined by the above methods with those theoretically predicted by taking into account the physical object dimensions and the motion amplitudes. The extreme locations were determined by the gradient method along the S-I axis through the center of the object. The centroid positions were determined by autocenter functions. The effect of motion period on the volume sizes was also studied.Results: It was found that the extreme locations of the objects determined from the two image modalities agreed with each other satisfactorily. They were not affected by the motion period. The average difference between the two modalities in the extreme locations was 0.68% for the cube, 1.35% for the sphere, and 0.5% for the cone, respectively. The maximum difference in the

  2. Accuracy of DXA scanning of the thoracic spine: cadaveric studies comparing BMC, areal BMD and geometric estimates of volumetric BMD against ash weight and CT measures of bone volume.

    PubMed

    Sran, Meena M; Khan, Karim M; Keiver, Kathy; Chew, Jason B; McKay, Heather A; Oxland, Thomas R

    2005-12-01

    Biomechanical studies of the thoracic spine often scan cadaveric segments by dual energy X-ray absorptiometry (DXA) to obtain measures of bone mass. Only one study has reported the accuracy of lateral scans of thoracic vertebral bodies. The accuracy of DXA scans of thoracic spine segments and of anterior-posterior (AP) thoracic scans has not been investigated. We have examined the accuracy of AP and lateral thoracic DXA scans by comparison with ash weight, the gold-standard for measuring bone mineral content (BMC). We have also compared three methods of estimating volumetric bone mineral density (vBMD) with a novel standard-ash weight (g)/bone volume (cm3) as measured by computed tomography (CT). Twelve T5-T8 spine segments were scanned with DXA (AP and lateral) and CT. The T6 vertebrae were excised, the posterior elements removed and then the vertebral bodies were ashed in a muffle furnace. We proposed a new method of estimating vBMD and compared it with two previously published methods. BMC values from lateral DXA scans displayed the strongest correlation with ash weight (r=0.99) and were on average 12.8% higher (p<0.001). As expected, BMC (AP or lateral) was more strongly correlated with ash weight than areal bone mineral density (aBMD; AP: r=0.54, or lateral: r=0.71) or estimated vBMD. Estimates of vBMD with either of the three methods were strongly and similarly correlated with volumetric BMD calculated by dividing ash weight by CT-derived volume. These data suggest that readily available DXA scanning is an appropriate surrogate measure for thoracic spine bone mineral and that the lateral scan might be the scan method of choice. PMID:15616862

  3. PET-Based Thoracic Radiation Oncology.

    PubMed

    Simone, Charles B; Houshmand, Sina; Kalbasi, Anusha; Salavati, Ali; Alavi, Abass

    2016-07-01

    Fluorodeoxyglucose-PET is increasingly being integrated into multiple aspects of oncology. PET/computed tomography (PET/CT) has become especially important in radiation oncology. With the increasing use of advanced techniques like intensity-modulated radiation therapy and proton therapy, PET/CT scans have played critical roles in the target delineation of tumors for radiation oncologists delivering conformal treatment techniques. Use of PET/CT is well established in lung cancer and several other thoracic malignancies. This article details the current uses of PET/CT in thoracic radiation oncology with a focus on lung cancer and describes expected future roles of PET/CT for thoracic tumors.

  4. Radiation dose reduction to the breast in thoracic CT: Comparison of bismuth shielding, organ-based tube current modulation, and use of a globally decreased tube current

    SciTech Connect

    Wang Jia; Duan Xinhui; Christner, Jodie A.; Leng Shuai; Yu Lifeng; McCollough, Cynthia H.

    2011-11-15

    Purpose: The purpose of this work was to evaluate dose performance and image quality in thoracic CT using three techniques to reduce dose to the breast: bismuth shielding, organ-based tube current modulation (TCM) and global tube current reduction. Methods: Semi-anthropomorphic thorax phantoms of four different sizes (15, 30, 35, and 40 cm lateral width) were used for dose measurement and image quality assessment. Four scans were performed on each phantom using 100 or 120 kV with a clinical CT scanner: (1) reference scan; (2) scan with bismuth breast shield of an appropriate thickness; (3) scan with organ-based TCM; and (4) scan with a global reduction in tube current chosen to match the dose reduction from bismuth shielding. Dose to the breast was measured with an ion chamber on the surface of the phantom. Image quality was evaluated by measuring the mean and standard deviation of CT numbers within the lung and heart regions. Results: Compared to the reference scan, dose to the breast region was decreased by about 21% for the 15-cm phantom with a pediatric (2-ply) shield and by about 37% for the 30, 35, and 40-cm phantoms with adult (4-ply) shields. Organ-based TCM decreased the dose by 12% for the 15-cm phantom, and 34-39% for the 30, 35, and 40-cm phantoms. Global lowering of the tube current reduced breast dose by 23% for the 15-cm phantom and 39% for the 30, 35, and 40-cm phantoms. In phantoms of all four sizes, image noise was increased in both the lung and heart regions with bismuth shielding. No significant increase in noise was observed with organ-based TCM. Decreasing tube current globally led to similar noise increases as bismuth shielding. Streak and beam hardening artifacts, and a resulting artifactual increase in CT numbers, were observed for scans with bismuth shields, but not for organ-based TCM or global tube current reduction. Conclusions: Organ-based TCM produces dose reduction to the breast similar to that achieved with bismuth shielding for

  5. Comparison of 128-Slice Low-Dose Prospective ECG-Gated CT Scanning and Trans-Thoracic Echocardiography for the Diagnosis of Complex Congenital Heart Disease

    PubMed Central

    Bu, Guilin; Miao, Ying; Bin, Jingwen; Deng, Sheng; Liu, Taowen; Jiang, Hongchun; Chen, Weiping

    2016-01-01

    Objective To compare prospective ECG-gated multi-slice computed tomography (MSCT) and trans-thoracic echocardiography (TTE) in the diagnosis of complex congenital heart disease (CHD). Methods This was a prospective study of consecutive patients with complex CHD (age <7 years) treated at a tertiary hospital between May 2013 and May 2015. All patients were imaged with TTE and prospective ECG-gated 128-slice spiral CT in the week before surgery. Effective radiation dose (ED) was calculated from volume CT dose index (CTDIvol) and dose length product (DLP). Image quality (5-point scale) was assessed independently by two radiologists. Using surgical findings as the reference, the diagnostic capabilities of MSCT and TTE were compared. Results Thirty-five patients (19 males) aged 1.59±1.58 years (range, 3 days to 74 months) were included. CTDIvol, DLP and ED were 0.90±0.24 mGy, 12.9±4.7 mGy∙cm and 0.64±0.21 mSv (range, 0.358–1.196 mSv), respectively. Image quality score was 4.3±0.5, and all images met the diagnostic requirements. The sensitivity, specificity, positive predictive value, and negative predictive value for diagnosing CHD were 97.2%, 99.8%, 99.0%, and 99.5%, respectively, for MSCT, and 90.6%, 99.8%, 99.0%, and 98.4%, respectively, for TTE. MSCT not only had a higher sensitivity than TTE overall (97.2% vs. 90.6%; P<0.05), but was much more sensitive for the diagnosis of extracardiac vascular abnormalities (92.0% vs. 68.0%; P<0.05). Conclusion 128-slice low-dose prospective ECG-gated CT scanning has important clinical value in the diagnosis of complex CHD in children, complementing and extending the findings of TTE. PMID:27788237

  6. 4-D Photoacoustic Tomography

    NASA Astrophysics Data System (ADS)

    Xiang, Liangzhong; Wang, Bo; Ji, Lijun; Jiang, Huabei

    2013-01-01

    Photoacoustic tomography (PAT) offers three-dimensional (3D) structural and functional imaging of living biological tissue with label-free, optical absorption contrast. These attributes lend PAT imaging to a wide variety of applications in clinical medicine and preclinical research. Despite advances in live animal imaging with PAT, there is still a need for 3D imaging at centimeter depths in real-time. We report the development of four dimensional (4D) PAT, which integrates time resolutions with 3D spatial resolution, obtained using spherical arrays of ultrasonic detectors. The 4D PAT technique generates motion pictures of imaged tissue, enabling real time tracking of dynamic physiological and pathological processes at hundred micrometer-millisecond resolutions. The 4D PAT technique is used here to image needle-based drug delivery and pharmacokinetics. We also use this technique to monitor 1) fast hemodynamic changes during inter-ictal epileptic seizures and 2) temperature variations during tumor thermal therapy.

  7. 4D Electron Tomography

    NASA Astrophysics Data System (ADS)

    Kwon, Oh-Hoon; Zewail, Ahmed H.

    2010-06-01

    Electron tomography provides three-dimensional (3D) imaging of noncrystalline and crystalline equilibrium structures, as well as elemental volume composition, of materials and biological specimens, including those of viruses and cells. We report the development of 4D electron tomography by integrating the fourth dimension (time resolution) with the 3D spatial resolution obtained from a complete tilt series of 2D projections of an object. The different time frames of tomograms constitute a movie of the object in motion, thus enabling studies of nonequilibrium structures and transient processes. The method was demonstrated using carbon nanotubes of a bracelet-like ring structure for which 4D tomograms display different modes of motion, such as breathing and wiggling, with resonance frequencies up to 30 megahertz. Applications can now make use of the full space-time range with the nanometer-femtosecond resolution of ultrafast electron tomography.

  8. Setup Reproducibility for Thoracic and Upper Gastrointestinal Radiation Therapy: Influence of Immobilization Method and On-Line Cone-Beam CT Guidance

    SciTech Connect

    Li, Winnie; Moseley, Douglas J.; Bissonnette, Jean-Pierre; Purdie, Thomas G.; Bezjak, Andrea; Jaffray, David A.

    2010-01-01

    We report the setup reproducibility of thoracic and upper gastrointestinal (UGI) radiotherapy (RT) patients for 2 immobilization methods evaluated through cone-beam computed tomography (CBCT) image guidance, and present planning target volume (PTV) margin calculations made on the basis of these observations. Daily CBCT images from 65 patients immobilized in a chestboard (CB) or evacuated cushion (EC) were registered to the planning CT using automatic bony anatomy registration. The standardized region-of-interest for matching was focused around vertebral bodies adjacent to tumor location. Discrepancies >3 mm between the CBCT and CT datasets were corrected before initiation of RT and verified with a second CBCT to assess residual error (usually taken after 90 s of the initial CBCT). Positional data were analyzed to evaluate the magnitude and frequencies of setup errors before and after correction. The setup distributions were slightly different for the CB (797 scans) and EC (757 scans) methods, and the probability of adjustment at a 3-mm action threshold was not significantly different (p = 0.47). Setup displacements >10 mm in any direction were observed in 10% of CB fractions and 16% of EC fractions (p = 0.0008). Residual error distributions after CBCT guidance were equivalent regardless of immobilization method. Using a published formula, the PTV margins for the CB were L/R, 3.3 mm; S/I, 3.5 mm; and A/P, 4.6 mm), and for EC they were L/R, 3.7 mm; S/I, 3.3 mm; and A/P, 4.6 mm. In the absence of image guidance, the CB slightly outperformed the EC in precision. CBCT allows reduction to a single immobilization system that can be chosen for efficiency, logistics, and cost. Image guidance allows for increased geometric precision and accuracy and supports a corresponding reduction in PTV margin.

  9. 4D flow imaging with MRI

    PubMed Central

    Stankovic, Zoran; Allen, Bradley D.; Garcia, Julio; Jarvis, Kelly B.

    2014-01-01

    Magnetic resonance imaging (MRI) has become an important tool for the clinical evaluation of patients with cardiovascular disease. Since its introduction in the late 1980s, 2-dimensional phase contrast MRI (2D PC-MRI) has become a routine part of standard-of-care cardiac MRI for the assessment of regional blood flow in the heart and great vessels. More recently, time-resolved PC-MRI with velocity encoding along all three flow directions and three-dimensional (3D) anatomic coverage (also termed ‘4D flow MRI’) has been developed and applied for the evaluation of cardiovascular hemodynamics in multiple regions of the human body. 4D flow MRI allows for the comprehensive evaluation of complex blood flow patterns by 3D blood flow visualization and flexible retrospective quantification of flow parameters. Recent technical developments, including the utilization of advanced parallel imaging techniques such as k-t GRAPPA, have resulted in reasonable overall scan times, e.g., 8-12 minutes for 4D flow MRI of the aorta and 10-20 minutes for whole heart coverage. As a result, the application of 4D flow MRI in a clinical setting has become more feasible, as documented by an increased number of recent reports on the utility of the technique for the assessment of cardiac and vascular hemodynamics in patient studies. A number of studies have demonstrated the potential of 4D flow MRI to provide an improved assessment of hemodynamics which might aid in the diagnosis and therapeutic management of cardiovascular diseases. The purpose of this review is to describe the methods used for 4D flow MRI acquisition, post-processing and data analysis. In addition, the article provides an overview of the clinical applications of 4D flow MRI and includes a review of applications in the heart, thoracic aorta and hepatic system. PMID:24834414

  10. Automated segmentation of the thyroid gland on thoracic CT scans by multiatlas label fusion and random forest classification.

    PubMed

    Narayanan, Divya; Liu, Jiamin; Kim, Lauren; Chang, Kevin W; Lu, Le; Yao, Jianhua; Turkbey, Evrim B; Summers, Ronald M

    2015-10-01

    The thyroid is an endocrine gland that regulates metabolism. Thyroid image analysis plays an important role in both diagnostic radiology and radiation oncology treatment planning. Low tissue contrast of the thyroid relative to surrounding anatomic structures makes manual segmentation of this organ challenging. This work proposes a fully automated system for thyroid segmentation on CT imaging. Following initial thyroid segmentation with multiatlas joint label fusion, a random forest (RF) algorithm was applied. Multiatlas label fusion transfers labels from labeled atlases and warps them to target images using deformable registration. A consensus atlas solution was formed based on optimal weighting of atlases and similarity to a given target image. Following the initial segmentation, a trained RF classifier employed voxel scanning to assign class-conditional probabilities to the voxels in the target image. Thyroid voxels were categorized with positive labels and nonthyroid voxels were categorized with negative labels. Our method was evaluated on CT scans from 66 patients, 6 of which served as atlases for multiatlas label fusion. The system with independent multiatlas label fusion method and RF classifier achieved average dice similarity coefficients of [Formula: see text] and [Formula: see text], respectively. The system with sequential multiatlas label fusion followed by RF correction increased the dice similarity coefficient to [Formula: see text] and improved the segmentation accuracy.

  11. Lung texture in serial thoracic CT scans: correlation with radiologist-defined severity of acute changes following radiation therapy

    NASA Astrophysics Data System (ADS)

    Cunliffe, Alexandra R.; Armato, Samuel G., III; Straus, Christopher; Malik, Renuka; Al-Hallaq, Hania A.

    2014-09-01

    This study examines the correlation between the radiologist-defined severity of normal tissue damage following radiation therapy (RT) for lung cancer treatment and a set of mathematical descriptors of computed tomography (CT) scan texture (‘texture features’). A pre-therapy CT scan and a post-therapy CT scan were retrospectively collected under IRB approval for each of the 25 patients who underwent definitive RT (median dose: 66 Gy). Sixty regions of interest (ROIs) were automatically identified in the non-cancerous lung tissue of each post-therapy scan. A radiologist compared post-therapy scan ROIs with pre-therapy scans and categorized each as containing no abnormality, mild abnormality, moderate abnormality, or severe abnormality. Twenty texture features that characterize gray-level intensity, region morphology, and gray-level distribution were calculated in post-therapy scan ROIs and compared with anatomically matched ROIs in the pre-therapy scan. Linear regression and receiver operating characteristic (ROC) analysis were used to compare the percent feature value change (ΔFV) between ROIs at each category of visible radiation damage. Most ROIs contained no (65%) or mild abnormality (30%). ROIs with moderate (3%) or severe (2%) abnormalities were observed in 9 patients. For 19 of 20 features, ΔFV was significantly different among severity levels. For 12 features, significant differences were observed at every level. Compared with regions with no abnormalities, ΔFV for these 12 features increased, on average, by 1.5%, 12%, and 30%, respectively, for mild, moderate, and severe abnormalitites. Area under the ROC curve was largest when comparing ΔFV in the highest severity level with the remaining three categories (mean AUC across features: 0.84). In conclusion, 19 features that characterized the severity of radiologic changes from pre-therapy scans were identified. These features may be used in future studies to quantify acute normal lung tissue damage

  12. Constrained reconstructions for 4D intervention guidance.

    PubMed

    Kuntz, J; Flach, B; Kueres, R; Semmler, W; Kachelriess, M; Bartling, S

    2013-05-21

    Image-guided interventions are an increasingly important part of clinical minimally invasive procedures. However, up to now they cannot be performed under 4D (3D + time) guidance due to the exceedingly high x-ray dose. In this work we investigate the applicability of compressed sensing reconstructions for highly undersampled CT datasets combined with the incorporation of prior images in order to yield low dose 4D intervention guidance. We present a new reconstruction scheme prior image dynamic interventional CT (PrIDICT) that accounts for specific image features in intervention guidance and compare it to PICCS and ASD-POCS. The optimal parameters for the dose per projection and the numbers of projections per reconstruction are determined in phantom simulations and measurements. In vivo experiments in six pigs are performed in a cone-beam CT; measured doses are compared to current gold-standard intervention guidance represented by a clinical fluoroscopy system. Phantom studies show maximum image quality for identical overall doses in the range of 14 to 21 projections per reconstruction. In vivo studies reveal that interventional materials can be followed in 4D visualization and that PrIDICT, compared to PICCS and ASD-POCS, shows superior reconstruction results and fewer artifacts in the periphery with dose in the order of biplane fluoroscopy. These results suggest that 4D intervention guidance can be realized with today's flat detector and gantry systems using the herein presented reconstruction scheme.

  13. Constrained reconstructions for 4D intervention guidance

    NASA Astrophysics Data System (ADS)

    Kuntz, J.; Flach, B.; Kueres, R.; Semmler, W.; Kachelrieß, M.; Bartling, S.

    2013-05-01

    Image-guided interventions are an increasingly important part of clinical minimally invasive procedures. However, up to now they cannot be performed under 4D (3D + time) guidance due to the exceedingly high x-ray dose. In this work we investigate the applicability of compressed sensing reconstructions for highly undersampled CT datasets combined with the incorporation of prior images in order to yield low dose 4D intervention guidance. We present a new reconstruction scheme prior image dynamic interventional CT (PrIDICT) that accounts for specific image features in intervention guidance and compare it to PICCS and ASD-POCS. The optimal parameters for the dose per projection and the numbers of projections per reconstruction are determined in phantom simulations and measurements. In vivo experiments in six pigs are performed in a cone-beam CT; measured doses are compared to current gold-standard intervention guidance represented by a clinical fluoroscopy system. Phantom studies show maximum image quality for identical overall doses in the range of 14 to 21 projections per reconstruction. In vivo studies reveal that interventional materials can be followed in 4D visualization and that PrIDICT, compared to PICCS and ASD-POCS, shows superior reconstruction results and fewer artifacts in the periphery with dose in the order of biplane fluoroscopy. These results suggest that 4D intervention guidance can be realized with today’s flat detector and gantry systems using the herein presented reconstruction scheme.

  14. CT angiography - chest

    MedlinePlus

    Computed tomography angiography - thorax; CTA - lungs; Pulmonary embolism - CTA chest; Thoracic aortic aneurysm - CTA chest; Venous thromboembolism - CTA lung; Blood clot - CTA lung; Embolus - CTA lung; CT ...

  15. Thoracic amebiasis.

    PubMed

    Shamsuzzaman, S M; Hashiguchi, Y

    2002-06-01

    cardiac failure or corpulmonale. Diagnosis by finding E histolytica in stool specimens is of limited value. In a limited number of cases amebae might be found in aspirated pus or expectorated sputum. "Anchovy sauce-like" pus or sputum may be found. Presence of bile in sputum indicates that the pus is of liver origin. Serological tests are of immense value in diagnosis. Liver enzymes are usually normal and neutrophilic leucocytosis may or may not be found. ESR is invariably elevated. Anti-amebic antibodies can be detected by ELISA, IFAT, and IHA. Amebic antigen can be detected from serum and pus by ELISA. Detection of Entamoeba DNA in pus or sputum may be a sensitive and specific method. Pleuropulmonary amebiasis is easily confused with other illnesses and is treated as pulmonary TB, bacterial lung abscesses, and carcinoma of the lung. A single drug regimen with metronidazole with supportive therapy usually cures patients without residual anomalies. Aspiration of pus from empyema thoracis may be needed for confirmation and therapeutic purposes. The pericardium is usually involved by direct extension from the amebic abscess of the left lobe of the liver, sometimes from the right lobe of the liver, and rarely from the lungs or pleura. An initial accumulation of serous fluid due to reactive pericarditis followed by intrapericardial rupture may develop either (1) acute onset of severe symptoms with chest pain, dyspnea, and cardiac tamponade, shock, and death, or (2) progressive effusion with thoracic cage pain, progressive dyspnea, and fever. Chest radiograph, ultrasound examination, and CT scan usually confirm the presence of a liver abscess in continuity with the pericardium and fluid within the pericardial sac with or without the fistulous tract. Echocardiography may demonstrate fluid in the pericardial cavity. Patients should be cared for in the ICU and ambecides should be started without delay. Pericardiocentesis usually confirms the diagnosis and improves the general

  16. Thoracic amebiasis.

    PubMed

    Shamsuzzaman, S M; Hashiguchi, Y

    2002-06-01

    cardiac failure or corpulmonale. Diagnosis by finding E histolytica in stool specimens is of limited value. In a limited number of cases amebae might be found in aspirated pus or expectorated sputum. "Anchovy sauce-like" pus or sputum may be found. Presence of bile in sputum indicates that the pus is of liver origin. Serological tests are of immense value in diagnosis. Liver enzymes are usually normal and neutrophilic leucocytosis may or may not be found. ESR is invariably elevated. Anti-amebic antibodies can be detected by ELISA, IFAT, and IHA. Amebic antigen can be detected from serum and pus by ELISA. Detection of Entamoeba DNA in pus or sputum may be a sensitive and specific method. Pleuropulmonary amebiasis is easily confused with other illnesses and is treated as pulmonary TB, bacterial lung abscesses, and carcinoma of the lung. A single drug regimen with metronidazole with supportive therapy usually cures patients without residual anomalies. Aspiration of pus from empyema thoracis may be needed for confirmation and therapeutic purposes. The pericardium is usually involved by direct extension from the amebic abscess of the left lobe of the liver, sometimes from the right lobe of the liver, and rarely from the lungs or pleura. An initial accumulation of serous fluid due to reactive pericarditis followed by intrapericardial rupture may develop either (1) acute onset of severe symptoms with chest pain, dyspnea, and cardiac tamponade, shock, and death, or (2) progressive effusion with thoracic cage pain, progressive dyspnea, and fever. Chest radiograph, ultrasound examination, and CT scan usually confirm the presence of a liver abscess in continuity with the pericardium and fluid within the pericardial sac with or without the fistulous tract. Echocardiography may demonstrate fluid in the pericardial cavity. Patients should be cared for in the ICU and ambecides should be started without delay. Pericardiocentesis usually confirms the diagnosis and improves the general

  17. Advances in 4D radiation therapy for managing respiration: part II - 4D treatment planning.

    PubMed

    Rosu, Mihaela; Hugo, Geoffrey D

    2012-12-01

    The development of 4D CT imaging technology made possible the creation of patient models that are reflective of respiration-induced anatomical changes by adding a temporal dimension to the conventional 3D, spatial-only, patient description. This had opened a new venue for treatment planning and radiation delivery, aimed at creating a comprehensive 4D radiation therapy process for moving targets. Unlike other breathing motion compensation strategies (e.g. breath-hold and gating techniques), 4D radiotherapy assumes treatment delivery over the entire respiratory cycle - an added bonus for both patient comfort and treatment time efficiency. The time-dependent positional and volumetric information holds the promise for optimal, highly conformal, radiotherapy for targets experiencing movements caused by respiration, with potentially elevated dose prescriptions and therefore higher cure rates, while avoiding the uninvolved nearby structures. In this paper, the current state of the 4D treatment planning is reviewed, from theory to the established practical routine. While the fundamental principles of 4D radiotherapy are well defined, the development of a complete, robust and clinically feasible process still remains a challenge, imposed by limitations in the available treatment planning and radiation delivery systems.

  18. Advances in 4D Radiation Therapy for Managing Respiration: Part II – 4D Treatment Planning

    PubMed Central

    Rosu, Mihaela; Hugo, Geoffrey D.

    2014-01-01

    The development of 4D CT imaging technology made possible the creation of patient models that are reflective of respiration-induced anatomical changes by adding a temporal dimension to the conventional 3D, spatial-only, patient description. This had opened a new venue for treatment planning and radiation delivery, aimed at creating a comprehensive 4D radiation therapy process for moving targets. Unlike other breathing motion compensation strategies (e.g. breath-hold and gating techniques), 4D radiotherapy assumes treatment delivery over the entire respiratory cycle – an added bonus for both patient comfort and treatment time efficiency. The time-dependent positional and volumetric information holds the promise for optimal, highly conformal, radiotherapy for targets experiencing movements caused by respiration, with potentially elevated dose prescriptions and therefore higher cure rates, while avoiding the uninvolved nearby structures. In this paper, the current state of the 4D treatment planning is reviewed, from theory to the established practical routine. While the fundamental principles of 4D radiotherapy are well defined, the development of a complete, robust and clinically feasible process still remains a challenge, imposed by limitations in the available treatment planning and radiation delivery systems. PMID:22796324

  19. A Prospective Evaluation of Staging and Target Volume Definition of Lymph Nodes by {sup 18}FDG PET/CT in Patients With Squamous Cell Carcinoma of Thoracic Esophagus

    SciTech Connect

    Yu Wen; Fu Xiaolong; Zhang Yingjian; Xiang Jiaqing; Shen Lei; Chang, Joe Y.

    2011-12-01

    Purpose: To determine an optimal standardized uptake value (SUV) threshold for detecting lymph node (LN) metastases in esophageal cancer using {sup 18}F-Fluorodeoxyglucose positron emission tomography/computer tomography ({sup 18}FDG PET/CT) and to define the resulting nodal target volume, using histopathology as a 'gold standard.' Methods: Sixteen patients with esophageal squamous cell carcinoma who underwent radical esophagectomy and three-field LN dissection after {sup 18}FDG PET/CT and CT scans were enrolled into this study. Locations of LN groups were recorded according to a uniform LN map. Diagnostic performance of different SUV thresholds was assessed by receiver operating characteristic analysis. The optimal cutoff SUV was determined by plotting the false-negative rate (FNR) and false-positive rate (FPR), the sum of both error rates (FNR+FPR), and accuracy against a hypothetical SUV threshold. For each patient, nodal gross tumor volumes (GTVNs) were generated with CT alone (GTVNCT), PET/CT (GTVNPET), and pathologic data (GTVNpath). GTVNCT or GTVNPET was compared with GTVNpath by means of a conformity index (CI), which is the intersection of the two GTVNs divided by the sum of them minus the intersection, e.g., CI{sub CT} and {sub path} = GTVN{sub CT} and {sub path}/(GTVN{sub CT}+ GTVN{sub path} - GTVN{sub CT} and {sub path}). Results: LN metastases occurred in 21 LN groups among the 144 specimens taken from the 16 patients. The area under the receiver operating characteristic curve was 0.9017 {+-} 0.0410. The plot of error rates showed a minimum of FNR+FPR for an SUV of 2.36, at which the sensitivity, specificity, and accuracy were 76.19%, 95.93%, and 93.06%, respectively, whereas those of CT were 33.33%, 94.31%, and 85.42% (p values: 0.0117, 0.7539, and 0.0266). Mean GTVN{sub CT}, GTVN{sub PET}, and GTVN{sub path} were 1.52 {+-} 2.38, 2.82 {+-} 4.51, and 2.68 {+-} 4.16cm{sup 3}, respectively. Mean CI{sub CT} and {sub path} and CI{sub PET} and {sub path

  20. Thoracic actinomycosis

    PubMed Central

    Slade, P. R.; Slesser, B. V.; Southgate, J.

    1973-01-01

    Six cases of pulmonary infection with Actinomyces Israeli and one case of infection with Nocardia asteroides are described. The incidence of thoracic actinomycosis has declined recently and the classical presentation with chronic discharging sinuses is now uncommon. The cases described illustrate some of the forms which the disease may take. Actinomycotic infection has been noted, not infrequently, to co-exist with bronchial carcinoma and a case illustrating this association is described. Sputum cytology as practised for the diagnosis of bronchial carcinoma has helped to identify the fungi in the sputum. Treatment is discussed, particularly the possible use of oral antibiotics rather than penicillin by injection. Images PMID:4568119

  1. Clinical Implementation of Intensity Modulated Proton Therapy for Thoracic Malignancies

    SciTech Connect

    Chang, Joe Y.; Li, Heng; Zhu, X. Ronald; Liao, Zhongxing; Zhao, Lina; Liu, Amy; Li, Yupeng; Sahoo, Narayan; Poenisch, Falk; Gomez, Daniel R.; Wu, Richard; Gillin, Michael; Zhang, Xiaodong

    2014-11-15

    Purpose: Intensity modulated proton therapy (IMPT) can improve dose conformality and better spare normal tissue over passive scattering techniques, but range uncertainties complicate its use, particularly for moving targets. We report our early experience with IMPT for thoracic malignancies in terms of motion analysis and management, plan optimization and robustness, and quality assurance. Methods and Materials: Thirty-four consecutive patients with lung/mediastinal cancers received IMPT to a median 66 Gy(relative biological equivalence [RBE]). All patients were able to undergo definitive radiation therapy. IMPT was used when the treating physician judged that IMPT conferred a dosimetric advantage; all patients had minimal tumor motion (<5 mm) and underwent individualized tumor-motion dose-uncertainty analysis and 4-dimensional (4D) computed tomographic (CT)-based treatment simulation and motion analysis. Plan robustness was optimized by using a worst-case scenario method. All patients had 4D CT repeated simulation during treatment. Results: IMPT produced lower mean lung dose (MLD), lung V{sub 5} and V{sub 20}, heart V{sub 40}, and esophageal V{sub 60} than did IMRT (P<.05) and lower MLD, lung V{sub 20}, and esophageal V{sub 60} than did passive scattering proton therapy (PSPT) (P<.05). D{sub 5} to the gross tumor volume and clinical target volume was higher with IMPT than with intensity modulated radiation therapy or PSPT (P<.05). All cases were analyzed for beam-angle-specific motion, water-equivalent thickness, and robustness. Beam angles were chosen to minimize the effect of respiratory motion and avoid previously treated regions, and the maximum deviation from the nominal dose-volume histogram values was kept at <5% for the target dose and met the normal tissue constraints under a worst-case scenario. Patient-specific quality assurance measurements showed that a median 99% (range, 95% to 100%) of the pixels met the 3% dose/3 mm distance criteria for the

  2. Thoracic target volume delineation using various maximum-intensity projection computed tomography image sets for radiotherapy treatment planning

    SciTech Connect

    Zamora, David A.; Riegel, Adam C.; Sun Xiaojun; Balter, Peter; Starkschall, George; Mawlawi, Osama; Pan Tinsu

    2010-11-15

    Purpose: Four-dimensional computed tomography (4D-CT) is commonly used to account for respiratory motion of target volumes in radiotherapy to the thorax. From the 4D-CT acquisition, a maximum-intensity projection (MIP) image set can be created and used to help define the tumor motion envelope or the internal gross tumor volume (iGTV). The purpose of this study was to quantify the differences in automatically contoured target volumes for usage in the delivery of stereotactic body radiation therapy using MIP data sets generated from one of the four methods: (1) 4D-CT phase-binned (PB) based on retrospective phase calculations, (2) 4D-CT phase-corrected phase-binned (PC-PB) based on motion extrema, (3) 4D-CT amplitude-binned (AB), and (4) cine CT built from all available images. Methods: MIP image data sets using each of the four methods were generated for a cohort of 28 patients who had prior thoracic 4D-CT scans that exhibited lung tumor motion of at least 1 cm. Each MIP image set was automatically contoured on commercial radiation treatment planning system. Margins were added to the iGTV to observe differences in the final simulated planning target volumes (PTVs). Results: For all patients, the iGTV measured on the MIP generated from the entire cine CT data set (iGTV{sub cine}) was the largest. Expressed as a percentage of iGTV{sub cine}, 4D-CT iGTV (all sorting methods) ranged from 83.8% to 99.1%, representing differences in the absolute volume ranging from 0.02 to 4.20 cm{sup 3}; the largest average and range of 4D-CT iGTV measurements was from the PC-PB data set. Expressed as a percentage of PTV{sub cine} (expansions applied to iGTV{sub cine}), the 4D-CT PTV ranged from 87.6% to 99.6%, representing differences in the absolute volume ranging from 0.08 to 7.42 cm{sup 3}. Regions of the measured respiratory waveform corresponding to a rapid change of phase or amplitude showed an increased susceptibility to the selection of identical images for adjacent bins

  3. 4D Proton treatment planning strategy for mobile lung tumors

    SciTech Connect

    Kang Yixiu; Zhang Xiaodong; Chang, Joe Y.; Wang He; Wei Xiong; Liao Zhongxing; Komaki, Ritsuko; Cox, James D.; Balter, Peter A.; Liu, Helen; Zhu, X. Ronald; Mohan, Radhe; Dong Lei . E-mail: ldong@mdanderson.org

    2007-03-01

    Purpose: To investigate strategies for designing compensator-based 3D proton treatment plans for mobile lung tumors using four-dimensional computed tomography (4DCT) images. Methods and Materials: Four-dimensional CT sets for 10 lung cancer patients were used in this study. The internal gross tumor volume (IGTV) was obtained by combining the tumor volumes at different phases of the respiratory cycle. For each patient, we evaluated four planning strategies based on the following dose calculations: (1) the average (AVE) CT; (2) the free-breathing (FB) CT; (3) the maximum intensity projection (MIP) CT; and (4) the AVE CT in which the CT voxel values inside the IGTV were replaced by a constant density (AVE{sub R}IGTV). For each strategy, the resulting cumulative dose distribution in a respiratory cycle was determined using a deformable image registration method. Results: There were dosimetric differences between the apparent dose distribution, calculated on a single CT dataset, and the motion-corrected 4D dose distribution, calculated by combining dose distributions delivered to each phase of the 4DCT. The AVE{sub R}IGTV plan using a 1-cm smearing parameter had the best overall target coverage and critical structure sparing. The MIP plan approach resulted in an unnecessarily large treatment volume. The AVE and FB plans using 1-cm smearing did not provide adequate 4D target coverage in all patients. By using a larger smearing value, adequate 4D target coverage could be achieved; however, critical organ doses were increased. Conclusion: The AVE{sub R}IGTV approach is an effective strategy for designing proton treatment plans for mobile lung tumors.

  4. TU-F-17A-01: BEST IN PHYSICS (JOINT IMAGING-THERAPY) - An Automatic Toolkit for Efficient and Robust Analysis of 4D Respiratory Motion

    SciTech Connect

    Wei, J; Yuan, A; Li, G

    2014-06-15

    Purpose: To provide an automatic image analysis toolkit to process thoracic 4-dimensional computed tomography (4DCT) and extract patient-specific motion information to facilitate investigational or clinical use of 4DCT. Methods: We developed an automatic toolkit in MATLAB to overcome the extra workload from the time dimension in 4DCT. This toolkit employs image/signal processing, computer vision, and machine learning methods to visualize, segment, register, and characterize lung 4DCT automatically or interactively. A fully-automated 3D lung segmentation algorithm was designed and 4D lung segmentation was achieved in batch mode. Voxel counting was used to calculate volume variations of the torso, lung and its air component, and local volume changes at the diaphragm and chest wall to characterize breathing pattern. Segmented lung volumes in 12 patients are compared with those from a treatment planning system (TPS). Voxel conversion was introduced from CT# to other physical parameters, such as gravity-induced pressure, to create a secondary 4D image. A demon algorithm was applied in deformable image registration and motion trajectories were extracted automatically. Calculated motion parameters were plotted with various templates. Machine learning algorithms, such as Naive Bayes and random forests, were implemented to study respiratory motion. This toolkit is complementary to and will be integrated with the Computational Environment for Radiotherapy Research (CERR). Results: The automatic 4D image/data processing toolkit provides a platform for analysis of 4D images and datasets. It processes 4D data automatically in batch mode and provides interactive visual verification for manual adjustments. The discrepancy in lung volume calculation between this and the TPS is <±2% and the time saving is by 1–2 orders of magnitude. Conclusion: A framework of 4D toolkit has been developed to analyze thoracic 4DCT automatically or interactively, facilitating both investigational

  5. A study of respiration-correlated cone-beam CT scans to correct target positioning errors in radiotherapy of thoracic cancer

    SciTech Connect

    Santoro, J. P.; McNamara, J.; Yorke, E.; Pham, H.; Rimner, A.; Rosenzweig, K. E.; Mageras, G. S.

    2012-10-15

    Purpose: There is increasingly widespread usage of cone-beam CT (CBCT) for guiding radiation treatment in advanced-stage lung tumors, but difficulties associated with daily CBCT in conventionally fractionated treatments include imaging dose to the patient, increased workload and longer treatment times. Respiration-correlated cone-beam CT (RC-CBCT) can improve localization accuracy in mobile lung tumors, but further increases the time and workload for conventionally fractionated treatments. This study investigates whether RC-CBCT-guided correction of systematic tumor deviations in standard fractionated lung tumor radiation treatments is more effective than 2D image-based correction of skeletal deviations alone. A second study goal compares respiration-correlated vs respiration-averaged images for determining tumor deviations. Methods: Eleven stage II-IV nonsmall cell lung cancer patients are enrolled in an IRB-approved prospective off-line protocol using RC-CBCT guidance to correct for systematic errors in GTV position. Patients receive a respiration-correlated planning CT (RCCT) at simulation, daily kilovoltage RC-CBCT scans during the first week of treatment and weekly scans thereafter. Four types of correction methods are compared: (1) systematic error in gross tumor volume (GTV) position, (2) systematic error in skeletal anatomy, (3) daily skeletal corrections, and (4) weekly skeletal corrections. The comparison is in terms of weighted average of the residual GTV deviations measured from the RC-CBCT scans and representing the estimated residual deviation over the treatment course. In the second study goal, GTV deviations computed from matching RCCT and RC-CBCT are compared to deviations computed from matching respiration-averaged images consisting of a CBCT reconstructed using all projections and an average-intensity-projection CT computed from the RCCT. Results: Of the eleven patients in the GTV-based systematic correction protocol, two required no correction

  6. Society of Thoracic Surgeons

    MedlinePlus

    ... With Its Intense Demands New Website from The Society of Thoracic Surgeons Puts the Power of Information ... Hotel Discount for STS Members Copyright © 2016 The Society of Thoracic Surgeons. All rights reserved. Expanded Proprietary ...

  7. SU-E-J-113: Effects of Deformable Registration On First-Order Texture Maps Calculated From Thoracic Lung CT Scans

    SciTech Connect

    Smith, C; Cunliffe, A; Al-Hallaq, H; Armato, S

    2015-06-15

    Purpose: To determine the stability of eight first-order texture features following the deformable registration of serial computed tomography (CT) scans. Methods: CT scans at two different time points from 10 patients deemed to have no lung abnormalities by a radiologist were collected. Following lung segmentation using an in-house program, texture maps were calculated from 32×32-pixel regions of interest centered at every pixel in the lungs. The texture feature value of the ROI was assigned to the center pixel of the ROI in the corresponding location of the texture map. Pixels in the square ROI not contained within the segmented lung were not included in the calculation. To quantify the agreement between ROI texture features in corresponding pixels of the baseline and follow-up texture maps, the Fraunhofer MEVIS EMPIRE10 deformable registration algorithm was used to register the baseline and follow-up scans. Bland-Altman analysis was used to compare registered scan pairs by computing normalized bias (nBias), defined as the feature value change normalized to the mean feature value, and normalized range of agreement (nRoA), defined as the range spanned by the 95% limits of agreement normalized to the mean feature value. Results: Each patient’s scans contained between 6.8–15.4 million ROIs. All of the first-order features investigated were found to have an nBias value less than 0.04% and an nRoA less than 19%, indicating that the variability introduced by deformable registration was low. Conclusion: The eight first-order features investigated were found to be registration stable. Changes in CT texture maps could allow for temporal-spatial evaluation of the evolution of lung abnormalities relating to a variety of diseases on a patient-by-patient basis. SGA and HA receives royalties and licensing fees through the University of Chicago for computer-aided diagnosis technology. Research reported in this publication was supported by the National Institute Of General

  8. Validation of a 4D-PET Maximum Intensity Projection for Delineation of an Internal Target Volume

    SciTech Connect

    Callahan, Jason; Kron, Tomas; Schneider-Kolsky, Michal; Dunn, Leon; Thompson, Mick; Siva, Shankar; Aarons, Yolanda; Binns, David; Hicks, Rodney J.

    2013-07-15

    Purpose: The delineation of internal target volumes (ITVs) in radiation therapy of lung tumors is currently performed by use of either free-breathing (FB) {sup 18}F-fluorodeoxyglucose-positron emission tomography-computed tomography (FDG-PET/CT) or 4-dimensional (4D)-CT maximum intensity projection (MIP). In this report we validate the use of 4D-PET-MIP for the delineation of target volumes in both a phantom and in patients. Methods and Materials: A phantom with 3 hollow spheres was prepared surrounded by air then water. The spheres and water background were filled with a mixture of {sup 18}F and radiographic contrast medium. A 4D-PET/CT scan was performed of the phantom while moving in 4 different breathing patterns using a programmable motion device. Nine patients with an FDG-avid lung tumor who underwent FB and 4D-PET/CT and >5 mm of tumor motion were included for analysis. The 3 spheres and patient lesions were contoured by 2 contouring methods (40% of maximum and PET edge) on the FB-PET, FB-CT, 4D-PET, 4D-PET-MIP, and 4D-CT-MIP. The concordance between the different contoured volumes was calculated using a Dice coefficient (DC). The difference in lung tumor volumes between FB-PET and 4D-PET volumes was also measured. Results: The average DC in the phantom using 40% and PET edge, respectively, was lowest for FB-PET/CT (DCAir = 0.72/0.67, DCBackground 0.63/0.62) and highest for 4D-PET/CT-MIP (DCAir = 0.84/0.83, DCBackground = 0.78/0.73). The average DC in the 9 patients using 40% and PET edge, respectively, was also lowest for FB-PET/CT (DC = 0.45/0.44) and highest for 4D-PET/CT-MIP (DC = 0.72/0.73). In the 9 lesions, the target volumes of the FB-PET using 40% and PET edge, respectively, were on average 40% and 45% smaller than the 4D-PET-MIP. Conclusion: A 4D-PET-MIP produces volumes with the highest concordance with 4D-CT-MIP across multiple breathing patterns and lesion sizes in both a phantom and among patients. Freebreathing PET/CT consistently

  9. Computer-aided diagnostic scheme for distinction between benign and malignant nodules in thoracic low-dose CT by use of massive training artificial neural network.

    PubMed

    Suzuki, Kenji; Li, Feng; Sone, Shusuke; Doi, Kunio

    2005-09-01

    Low-dose helical computed tomography (LDCT) is being applied as a modality for lung cancer screening. It may be difficult, however, for radiologists to distinguish malignant from benign nodules in LDCT. Our purpose in this study was to develop a computer-aided diagnostic (CAD) scheme for distinction between benign and malignant nodules in LDCT scans by use of a massive training artificial neural network (MTANN). The MTANN is a trainable, highly nonlinear filter based on an artificial neural network. To distinguish malignant nodules from six different types of benign nodules, we developed multiple MTANNs (multi-MTANN) consisting of six expert MTANNs that are arranged in parallel. Each of the MTANNs was trained by use of input CT images and teaching images containing the estimate of the distribution for the "likelihood of being a malignant nodule," i.e., the teaching image for a malignant nodule contains a two-dimensional Gaussian distribution and that for a benign nodule contains zero. Each MTANN was trained independently with ten typical malignant nodules and ten benign nodules from each of the six types. The outputs of the six MTANNs were combined by use of an integration ANN such that the six types of benign nodules could be distinguished from malignant nodules. After training of the integration ANN, our scheme provided a value related to the "likelihood of malignancy" of a nodule, i.e., a higher value indicates a malignant nodule, and a lower value indicates a benign nodule. Our database consisted of 76 primary lung cancers in 73 patients and 413 benign nodules in 342 patients, which were obtained from a lung cancer screening program on 7847 screenees with LDCT for three years in Nagano, Japan. The performance of our scheme for distinction between benign and malignant nodules was evaluated by use of receiver operating characteristic (ROC) analysis. Our scheme achieved an Az (area under the ROC curve) value of 0.882 in a round-robin test. Our scheme correctly

  10. Thoracic outlet syndrome.

    PubMed

    Kuhn, John E; Lebus V, George F; Bible, Jesse E

    2015-04-01

    Thoracic outlet syndrome is a well-described disorder caused by thoracic outlet compression of the brachial plexus and/or the subclavian vessels. Neurogenic thoracic outlet syndrome is the most common manifestation, presenting with pain, numbness, tingling, weakness, and vasomotor changes of the upper extremity. Vascular complications of thoracic outlet syndrome are uncommon and include thromboembolic phenomena and swelling. The clinical presentation is highly variable, and no reproducible study exists to confirm the diagnosis; instead, the diagnosis is based on a physician's judgment after a meticulous history and physical examination. Both nonsurgical and surgical treatment methods are available for thoracic outlet syndrome. Whereas nonsurgical management appears to be effective in some persons, surgical treatment has been shown to provide predictable long-term cure rates for carefully selected patients. In addition, physicians who do not regularly treat patients with thoracic outlet syndrome may not have an accurate view of this disorder, its treatment, or the possible success rate of treatment. PMID:25808686

  11. Thoracic outlet syndrome.

    PubMed

    Kuhn, John E; Lebus V, George F; Bible, Jesse E

    2015-04-01

    Thoracic outlet syndrome is a well-described disorder caused by thoracic outlet compression of the brachial plexus and/or the subclavian vessels. Neurogenic thoracic outlet syndrome is the most common manifestation, presenting with pain, numbness, tingling, weakness, and vasomotor changes of the upper extremity. Vascular complications of thoracic outlet syndrome are uncommon and include thromboembolic phenomena and swelling. The clinical presentation is highly variable, and no reproducible study exists to confirm the diagnosis; instead, the diagnosis is based on a physician's judgment after a meticulous history and physical examination. Both nonsurgical and surgical treatment methods are available for thoracic outlet syndrome. Whereas nonsurgical management appears to be effective in some persons, surgical treatment has been shown to provide predictable long-term cure rates for carefully selected patients. In addition, physicians who do not regularly treat patients with thoracic outlet syndrome may not have an accurate view of this disorder, its treatment, or the possible success rate of treatment.

  12. 4-D OCT in Developmental Cardiology

    NASA Astrophysics Data System (ADS)

    Jenkins, Michael W.; Rollins, Andrew M.

    Although strong evidence exists to suggest that altered cardiac function can lead to CHDs, few studies have investigated the influential role of cardiac function and biophysical forces on the development of the cardiovascular system due to a lack of proper in vivo imaging tools. 4-D imaging is needed to decipher the complex spatial and temporal patterns of biomechanical forces acting upon the heart. Numerous solutions over the past several years have demonstrated 4-D OCT imaging of the developing cardiovascular system. This chapter will focus on these solutions and explain their context in the evolution of 4-D OCT imaging. The first sections describe the relevant techniques (prospective gating, direct 4-D imaging, retrospective gating), while later sections focus on 4-D Doppler imaging and measurements of force implementing 4-D OCT Doppler. Finally, the techniques are summarized, and some possible future directions are discussed.

  13. 4D VMAT, gated VMAT, and 3D VMAT for stereotactic body radiation therapy in lung.

    PubMed

    Chin, E; Loewen, S K; Nichol, A; Otto, K

    2013-02-21

    Four-dimensional volumetric modulated arc therapy (4D VMAT) is a treatment strategy for lung cancers that aims to exploit relative target and tissue motion to improve organ at risk (OAR) sparing. The algorithm incorporates the entire patient respiratory cycle using 4D CT data into the optimization process. Resulting treatment plans synchronize the delivery of each beam aperture to a specific phase of target motion. Stereotactic body radiation therapy treatment plans for 4D VMAT, gated VMAT, and 3D VMAT were generated on three patients with non-small cell lung cancer. Tumour motion ranged from 1.4-3.4 cm. The dose and fractionation scheme was 48 Gy in four fractions. A B-spline transformation model registered the 4D CT images. 4D dose volume histograms (4D DVH) were calculated from total dose accumulated at the maximum exhalation. For the majority of OARs, gated VMAT achieved the most radiation sparing but treatment times were 77-148% longer than 3D VMAT. 4D VMAT plan qualities were comparable to gated VMAT, but treatment times were only 11-25% longer than 3D VMAT. 4D VMAT's improvement of healthy tissue sparing can allow for further dose escalation. Future study could potentially adapt 4D VMAT to irregular patient breathing patterns.

  14. A sinogram warping strategy for pre-reconstruction 4D PET optimization.

    PubMed

    Gianoli, Chiara; Riboldi, Marco; Fontana, Giulia; Kurz, Christopher; Parodi, Katia; Baroni, Guido

    2016-03-01

    A novel strategy for 4D PET optimization in the sinogram domain is proposed, aiming at motion model application before image reconstruction ("sinogram warping" strategy). Compared to state-of-the-art 4D-MLEM reconstruction, the proposed strategy is able to optimize the image SNR, avoiding iterative direct and inverse warping procedures, which are typical of the 4D-MLEM algorithm. A full-count statistics sinogram of the motion-compensated 4D PET reference phase is generated by warping the sinograms corresponding to the different PET phases. This is achieved relying on a motion model expressed in the sinogram domain. The strategy was tested on the anthropomorphic 4D PET-CT NCAT phantom in comparison with the 4D-MLEM algorithm, with particular reference to robustness to PET-CT co-registrations artefacts. The MLEM reconstruction of the warped sinogram according to the proposed strategy exhibited better accuracy (up to +40.90 % with respect to the ideal value), whereas images reconstructed according to the 4D-MLEM reconstruction resulted in less noisy (down to -26.90 % with respect to the ideal value) but more blurred. The sinogram warping strategy demonstrates advantages with respect to 4D-MLEM algorithm. These advantages are paid back by introducing approximation of the deformation field, and further efforts are required to mitigate the impact of such an approximation in clinical 4D PET reconstruction.

  15. 4D VMAT, gated VMAT, and 3D VMAT for stereotactic body radiation therapy in lung

    NASA Astrophysics Data System (ADS)

    Chin, E.; Loewen, S. K.; Nichol, A.; Otto, K.

    2013-02-01

    Four-dimensional volumetric modulated arc therapy (4D VMAT) is a treatment strategy for lung cancers that aims to exploit relative target and tissue motion to improve organ at risk (OAR) sparing. The algorithm incorporates the entire patient respiratory cycle using 4D CT data into the optimization process. Resulting treatment plans synchronize the delivery of each beam aperture to a specific phase of target motion. Stereotactic body radiation therapy treatment plans for 4D VMAT, gated VMAT, and 3D VMAT were generated on three patients with non-small cell lung cancer. Tumour motion ranged from 1.4-3.4 cm. The dose and fractionation scheme was 48 Gy in four fractions. A B-spline transformation model registered the 4D CT images. 4D dose volume histograms (4D DVH) were calculated from total dose accumulated at the maximum exhalation. For the majority of OARs, gated VMAT achieved the most radiation sparing but treatment times were 77-148% longer than 3D VMAT. 4D VMAT plan qualities were comparable to gated VMAT, but treatment times were only 11-25% longer than 3D VMAT. 4D VMAT's improvement of healthy tissue sparing can allow for further dose escalation. Future study could potentially adapt 4D VMAT to irregular patient breathing patterns.

  16. Chondromyxoid fibroma of two thoracic vertebrae.

    PubMed

    Bruder, E; Zanetti, M; Boos, N; von Hochstetter, A R

    1999-05-01

    We report on a case of chondromyxoid fibroma involving two adjacent thoracic vertebrae with features of aggressive behaviour on radiographs, CT and MRI. Histology revealed typical chondromyxoid fibroma with unusually coarse calcifications. Chondromyxoid fibroma of the spine is rare, and only 30 of these tumours have been reported so far. Involvement of two contiguous vertebral bodies by chondromyxoid fibroma, as reported here, appears exceptional. PMID:10424337

  17. Endovascular intervention in thoracic arterial trauma.

    PubMed

    Hoffer, Eric K

    2008-11-01

    The management of thoracic vascular injury has improved dramatically over the past two decades. The availability of multi-row detector CT has facilitated early diagnosis and incorporation of minimally invasive endograft repair for traumatic aortic injury has improved mortality and paraplegia rates. This review evaluates the available data on stent-graft repair of acute blunt traumatic aortic injury and traumatic great vessel injury with regard to safety and efficacy in comparison with conventional open surgical repair. PMID:18842261

  18. Advances in 4D radiation therapy for managing respiration: part I - 4D imaging.

    PubMed

    Hugo, Geoffrey D; Rosu, Mihaela

    2012-12-01

    Techniques for managing respiration during imaging and planning of radiation therapy are reviewed, concentrating on free-breathing (4D) approaches. First, we focus on detailing the historical development and basic operational principles of currently-available "first generation" 4D imaging modalities: 4D computed tomography, 4D cone beam computed tomography, 4D magnetic resonance imaging, and 4D positron emission tomography. Features and limitations of these first generation systems are described, including necessity of breathing surrogates for 4D image reconstruction, assumptions made in acquisition and reconstruction about the breathing pattern, and commonly-observed artifacts. Both established and developmental methods to deal with these limitations are detailed. Finally, strategies to construct 4D targets and images and, alternatively, to compress 4D information into static targets and images for radiation therapy planning are described.

  19. Advances in 4D Radiation Therapy for Managing Respiration: Part I – 4D Imaging

    PubMed Central

    Hugo, Geoffrey D.; Rosu, Mihaela

    2014-01-01

    Techniques for managing respiration during imaging and planning of radiation therapy are reviewed, concentrating on free-breathing (4D) approaches. First, we focus on detailing the historical development and basic operational principles of currently-available “first generation” 4D imaging modalities: 4D computed tomography, 4D cone beam computed tomography, 4D magnetic resonance imaging, and 4D positron emission tomography. Features and limitations of these first generation systems are described, including necessity of breathing surrogates for 4D image reconstruction, assumptions made in acquisition and reconstruction about the breathing pattern, and commonly-observed artifacts. Both established and developmental methods to deal with these limitations are detailed. Finally, strategies to construct 4D targets and images and, alternatively, to compress 4D information into static targets and images for radiation therapy planning are described. PMID:22784929

  20. Rare case of thoracic kidney detected by renal scintigraphy

    PubMed Central

    Natarajan, Aravintho; Agrawal, Archi; Purandare, Nilendu; Shah, Sneha; Rangarajan, Venkatesh

    2016-01-01

    Intrathoracic kidney is a rare congenital abnormality with lowest frequency among all renal ectopias. Patients with thoracic kidneys are usually asymptomatic, and the condition is usually discovered incidentally during radiological evaluation for other conditions or during thoracic surgery. We report a case of a 62-year-old male who was referred to our department for renal scintigraphy for a nonvisualized left kidney on ultrasonography report. Both Tc-99m dimercaptosuccinic acid and diethylenetriaminepentaacetic acid scans revealed a left thoracic kidney which was confirmed by CT scan of the thorax and abdomen. PMID:27385896

  1. SU-E-J-209: Geometric Distortion at 3T in a Commercial 4D MRI-Compatible Phantom

    SciTech Connect

    Fatemi-Ardekani, A; Wronski, M; Kim, A; Stanisz, G; Sarfehnia, A; Keller, B

    2015-06-15

    Purpose: There are very few commercial 4D phantoms that are marketed as MRI compatible. We are evaluating one such commercial phantom, made to be used with an MRI-Linear accelerator. The focus of this work is to characterize the geometric distortions produced in this phantom at 3T using 3 clinical MR pulse sequences. Methods: The CIRS MRI-Linac Dynamic Phantom (CIRSTM) under investigation in this study consists of a softwaredriven moving tumour volume within a thorax phantom body and enables dose accumulation by placing a dosimeter within the tumour volume. Our initial investigation is to evaluate the phantom in static mode prior to examining its 4D capability. The water-filled thorax phantom was scanned using a wide-bore Philips 3T Achieva MRI scanner employing a Thoracic xl coil and clinical 2D T1W FFE, 2D T1W TSE and 3D T1W TFE pulse sequences. Each of the MR image sets was rigidly fused with a reference CT image of the phantom employing a rigid registration with 6 degrees of freedom. Geometric distortions between the MR and CT image sets were measured in 3 dimensions at selected points along the periphery of the distortion grid embedded within the phantom body (11.5, 7.5 and 3 cm laterally, ant/post and sup/inf of magnetic isocenter respectively). Results: The maximal measured geometric distortions between the MR and reference CT points of interest were 0.9, 1.8 and 1.3 mm in the lateral, anteriorposterior and cranio-caudal directions, respectively. For all 3 spatial dimensions, the maximal distortions occurred for the FFE pulse sequence. Maximal distortions for the 2D FFE, 2D TSE and 3D TFE sequences were 1, 0.7 and 1.8 mm, respectively. Conclusion: Our initial static investigation of this phantom shows minimal geometric distortions at 3T along the periphery of the embedded grid. CIRS has provided us with a phantom at no charge for evaluation at 3 Tesla.

  2. 4D XCAT phantom for multimodality imaging research

    SciTech Connect

    Segars, W. P.; Sturgeon, G.; Mendonca, S.; Grimes, Jason; Tsui, B. M. W.

    2010-09-15

    Purpose: The authors develop the 4D extended cardiac-torso (XCAT) phantom for multimodality imaging research. Methods: Highly detailed whole-body anatomies for the adult male and female were defined in the XCAT using nonuniform rational B-spline (NURBS) and subdivision surfaces based on segmentation of the Visible Male and Female anatomical datasets from the National Library of Medicine as well as patient datasets. Using the flexibility of these surfaces, the Visible Human anatomies were transformed to match body measurements and organ volumes for a 50th percentile (height and weight) male and female. The desired body measurements for the models were obtained using the PEOPLESIZE program that contains anthropometric dimensions categorized from 1st to the 99th percentile for US adults. The desired organ volumes were determined from ICRP Publication 89 [ICRP, ''Basic anatomical and physiological data for use in radiological protection: reference values,'' ICRP Publication 89 (International Commission on Radiological Protection, New York, NY, 2002)]. The male and female anatomies serve as standard templates upon which anatomical variations may be modeled in the XCAT through user-defined parameters. Parametrized models for the cardiac and respiratory motions were also incorporated into the XCAT based on high-resolution cardiac- and respiratory-gated multislice CT data. To demonstrate the usefulness of the phantom, the authors show example simulation studies in PET, SPECT, and CT using publicly available simulation packages. Results: As demonstrated in the pilot studies, the 4D XCAT (which includes thousands of anatomical structures) can produce realistic imaging data when combined with accurate models of the imaging process. With the flexibility of the NURBS surface primitives, any number of different anatomies, cardiac or respiratory motions or patterns, and spatial resolutions can be simulated to perform imaging research. Conclusions: With the ability to produce

  3. 4D XCAT phantom for multimodality imaging research

    PubMed Central

    Segars, W. P.; Sturgeon, G.; Mendonca, S.; Grimes, Jason; Tsui, B. M. W.

    2010-01-01

    Purpose: The authors develop the 4D extended cardiac-torso (XCAT) phantom for multimodality imaging research. Methods: Highly detailed whole-body anatomies for the adult male and female were defined in the XCAT using nonuniform rational B-spline (NURBS) and subdivision surfaces based on segmentation of the Visible Male and Female anatomical datasets from the National Library of Medicine as well as patient datasets. Using the flexibility of these surfaces, the Visible Human anatomies were transformed to match body measurements and organ volumes for a 50th percentile (height and weight) male and female. The desired body measurements for the models were obtained using the PEOPLESIZE program that contains anthropometric dimensions categorized from 1st to the 99th percentile for US adults. The desired organ volumes were determined from ICRP Publication 89 [ICRP, ‘‘Basic anatomical and physiological data for use in radiological protection: reference values,” ICRP Publication 89 (International Commission on Radiological Protection, New York, NY, 2002)]. The male and female anatomies serve as standard templates upon which anatomical variations may be modeled in the XCAT through user-defined parameters. Parametrized models for the cardiac and respiratory motions were also incorporated into the XCAT based on high-resolution cardiac- and respiratory-gated multislice CT data. To demonstrate the usefulness of the phantom, the authors show example simulation studies in PET, SPECT, and CT using publicly available simulation packages. Results: As demonstrated in the pilot studies, the 4D XCAT (which includes thousands of anatomical structures) can produce realistic imaging data when combined with accurate models of the imaging process. With the flexibility of the NURBS surface primitives, any number of different anatomies, cardiac or respiratory motions or patterns, and spatial resolutions can be simulated to perform imaging research. Conclusions: With the ability to produce

  4. Thoracic Aortic Stent-Graft Placement for Safe Removal of a Malpositioned Pedicle Screw

    SciTech Connect

    Hu Hongtao; Shin, Ji Hoon Hwang, Jae-Yeon; Cho, Young Jun; Ko, Gi-Young; Yoon, Hyun-Ki

    2010-10-15

    We describe a case of percutaneous placement of a thoracic aortic stent-graft for safe removal of a malpositioned pedicle screw in a 52-year-old man. The patient had undergone posterior thoracic spinal instrumentation for pyogenic spondylitis and spinal deformity 8 months previously. Follow-up CT images showed a malpositioned pedicle screw which was abutting the thoracic aorta at the T5 level. After percutaneous stent-graft placement, the malpositioned pedicle screw was safely and successfully removed.

  5. Los Alamos National Laboratory 4D Database

    SciTech Connect

    Atencio, Julian J.

    2014-05-02

    4D is an integrated development platform - a single product comprised of the components you need to create and distribute professional applications. You get a graphical design environment, SQL database, a programming language, integrated PHP execution, HTTP server, application server, executable generator, and much more. 4D offers multi-platform development and deployment, meaning whatever you create on a Mac can be used on Windows, and vice-versa. Beyond productive development, 4D is renowned for its great flexibility in maintenance and modification of existing applications, and its extreme ease of implementation in its numerous deployment options. Your professional application can be put into production more quickly, at a lower cost, and will always be instantly scalable. 4D makes it easy, whether you're looking to create a classic desktop application, a client-server system, a distributed solution for Web or mobile clients - or all of the above!

  6. Endoscopic thoracic sympathectomy

    MedlinePlus

    Endoscopic thoracic sympathectomy (ETS) is surgery to treat sweating that is much heavier than normal. This condition ... hyperhidrosis . Usually the surgery is used to treat sweating in the palms or face. The sympathetic nerves ...

  7. Thoracic intrathymic thyroid.

    PubMed Central

    Spinner, R J; Moore, K L; Gottfried, M R; Lowe, J E; Sabiston, D C

    1994-01-01

    OBJECTIVE: The authors introduce thoracic intrathymic thyroid as a clinical entity. SUMMARY BACKGROUND DATA: Although accessory aberrant thyroid has not been found in other tissues in the mediastinum, a thoracic intrathymic location has not been described previously. It is believed that mediastinal thyroid tissue represents accessory ectopic tissue from the median thyroid anlage. Moreover, the close association of the thymus and thyroid supports the theory that mediastinal ectopic thyroid tissue develops from abnormal descent of these structures during embryogenesis. METHODS: Benign thoracic intrathymic thyroid lesions are described in patients with mediastinal masses. CONCLUSION: Thoracic intrathymic thyroid is a distinct entity. Its occurrence is supported both clinically and embryologically. Images Figure 1. Figure 2. Figure 3. Figure 4. Figure 5. Figure 6. Figure 7. PMID:8024364

  8. Thoracic Outlet Syndrome

    MedlinePlus

    Thoracic outlet syndrome (TOS) causes pain in the shoulder, arm, and neck. It happens when the nerves or blood vessels just below your ... vein is compressed, your hand might be sensitive to cold, or turn pale or bluish. Your arm ...

  9. TU-C-BRD-01: Image Guided SBRT I: Multi-Modality 4D Imaging

    SciTech Connect

    Cai, J; Mageras, G; Pan, T

    2014-06-15

    Motion management is one of the critical technical challenges for radiation therapy. 4D imaging has been rapidly adopted as essential tool to assess organ motion associated with respiratory breathing. A variety of 4D imaging techniques have been developed and are currently under development based on different imaging modalities such as CT, MRI, PET, and CBCT. Each modality provides specific and complementary information about organ and tumor respiratory motion. Effective use of each different technique or combined use of different techniques can introduce a comprehensive management of tumor motion. Specifically, these techniques have afforded tremendous opportunities to better define and delineate tumor volumes, more accurately perform patient positioning, and effectively apply highly conformal therapy techniques such as IMRT and SBRT. Successful implementation requires good understanding of not only each technique, including unique features, limitations, artifacts, imaging acquisition and process, but also how to systematically apply the information obtained from different imaging modalities using proper tools such as deformable image registration. Furthermore, it is important to understand the differences in the effects of breathing variation between different imaging modalities. A comprehensive motion management strategy using multi-modality 4D imaging has shown promise in improving patient care, but at the same time faces significant challenges. This session will focuses on the current status and advances in imaging respiration-induced organ motion with different imaging modalities: 4D-CT, 4D-MRI, 4D-PET, and 4D-CBCT/DTS. Learning Objectives: Understand the need and role of multimodality 4D imaging in radiation therapy. Understand the underlying physics behind each 4D imaging technique. Recognize the advantages and limitations of each 4D imaging technique.

  10. Phosphodiesterase4D (PDE4D)--A risk factor for atrial fibrillation and stroke?

    PubMed

    Jørgensen, Carina; Yasmeen, Saiqa; Iversen, Helle K; Kruuse, Christina

    2015-12-15

    Mutations in the gene encoding phosphodiesterase 4D (PDE4D) enzyme are associated with ischemic stroke; however the functional implications of such mutations are not well understood. PDE4D is part of a complex protein family modulating intracellular signalling by cyclic nucleotides. The PDE4 family includes subtypes A-D, all of which show unique intracellular, cellular and tissue distribution. PDE4D is the major subtype expressed in human atrial myocytes and involved in the pathophysiology of arrhythmias, such as atrial fibrillation. The PDE4D enzyme hydrolyses cyclic adenosine monophosphate (cAMP). Though diverging results are reported, several population based studies describe association of various PDE4D single nucleotide polymorphisms (SNP) with cardio-embolic stroke in particular. Functionally, a down regulation of PDE4D variants has been reported in stroke patients. The anti-inflammatory and vasodilator properties of PDE4 inhibitors make them suitable for treatment of stroke and cardiovascular disease. PDE4D has recently been suggested as factor in atrial fibrillation. This review summarizes the possible function of PDE4D in the brain, heart, and vasculature. Further, association of the described SNPs, in particular, with cardioembolic stroke, is reviewed. Current findings on the PDE4D mutations suggest functionality involves an increased cardiac risk factor as well as augmented risk of atrial fibrillation. PMID:26671126

  11. Impact of incorporating visual biofeedback in 4D MRI.

    PubMed

    To, David T; Kim, Joshua P; Price, Ryan G; Chetty, Indrin J; Glide-Hurst, Carri K

    2016-05-08

    Precise radiation therapy (RT) for abdominal lesions is complicated by respiratory motion and suboptimal soft tissue contrast in 4D CT. 4D MRI offers improved con-trast although long scan times and irregular breathing patterns can be limiting. To address this, visual biofeedback (VBF) was introduced into 4D MRI. Ten volunteers were consented to an IRB-approved protocol. Prospective respiratory-triggered, T2-weighted, coronal 4D MRIs were acquired on an open 1.0T MR-SIM. VBF was integrated using an MR-compatible interactive breath-hold control system. Subjects visually monitored their breathing patterns to stay within predetermined tolerances. 4D MRIs were acquired with and without VBF for 2- and 8-phase acquisitions. Normalized respiratory waveforms were evaluated for scan time, duty cycle (programmed/acquisition time), breathing period, and breathing regularity (end-inhale coefficient of variation, EI-COV). Three reviewers performed image quality assessment to compare artifacts with and without VBF. Respiration-induced liver motion was calculated via centroid difference analysis of end-exhale (EE) and EI liver contours. Incorporating VBF reduced 2-phase acquisition time (4.7 ± 1.0 and 5.4 ± 1.5 min with and without VBF, respectively) while reducing EI-COV by 43.8% ± 16.6%. For 8-phase acquisitions, VBF reduced acquisition time by 1.9 ± 1.6 min and EI-COVs by 38.8% ± 25.7% despite breathing rate remaining similar (11.1 ± 3.8 breaths/min with vs. 10.5 ± 2.9 without). Using VBF yielded higher duty cycles than unguided free breathing (34.4% ± 5.8% vs. 28.1% ± 6.6%, respectively). Image grading showed that out of 40 paired evaluations, 20 cases had equivalent and 17 had improved image quality scores with VBF, particularly for mid-exhale and EI. Increased liver excursion was observed with VBF, where superior-inferior, anterior-posterior, and left-right EE-EI displacements were 14.1± 5.8, 4.9 ± 2.1, and 1.5 ± 1.0 mm, respectively, with VBF compared to 11.9

  12. IMRT treatment planning on 4D geometries for the era of dynamic MLC tracking.

    PubMed

    Suh, Yelin; Murray, Walter; Keall, Paul J

    2014-12-01

    score by 4-50% compared with 3D optimization. The 4D treatment plans had leaf sequences that varied from phase to phase to account for anatomic motion, but showed similar target dose distributions in each phase. The current method could in principle be generalized for use in offline replanning between fractions or for online 4D treatment planning based on 4D cone-beam CT images. Computation time remains a challenge.

  13. Shadow-driven 4D haptic visualization.

    PubMed

    Zhang, Hui; Hanson, Andrew

    2007-01-01

    Just as we can work with two-dimensional floor plans to communicate 3D architectural design, we can exploit reduced-dimension shadows to manipulate the higher-dimensional objects generating the shadows. In particular, by taking advantage of physically reactive 3D shadow-space controllers, we can transform the task of interacting with 4D objects to a new level of physical reality. We begin with a teaching tool that uses 2D knot diagrams to manipulate the geometry of 3D mathematical knots via their projections; our unique 2D haptic interface allows the user to become familiar with sketching, editing, exploration, and manipulation of 3D knots rendered as projected imageson a 2D shadow space. By combining graphics and collision-sensing haptics, we can enhance the 2D shadow-driven editing protocol to successfully leverage 2D pen-and-paper or blackboard skills. Building on the reduced-dimension 2D editing tool for manipulating 3D shapes, we develop the natural analogy to produce a reduced-dimension 3D tool for manipulating 4D shapes. By physically modeling the correct properties of 4D surfaces, their bending forces, and their collisions in the 3D haptic controller interface, we can support full-featured physical exploration of 4D mathematical objects in a manner that is otherwise far beyond the experience accessible to human beings. As far as we are aware, this paper reports the first interactive system with force-feedback that provides "4D haptic visualization" permitting the user to model and interact with 4D cloth-like objects.

  14. 4D Confocal Imaging of Yeast Organelles.

    PubMed

    Day, Kasey J; Papanikou, Effrosyni; Glick, Benjamin S

    2016-01-01

    Yeast cells are well suited to visualizing organelles by 4D confocal microscopy. Typically, one or more cellular compartments are labeled with a fluorescent protein or dye, and a stack of confocal sections spanning the entire cell volume is captured every few seconds. Under appropriate conditions, organelle dynamics can be observed for many minutes with only limited photobleaching. Images are captured at a relatively low signal-to-noise ratio and are subsequently processed to generate movies that can be analyzed and quantified. Here, we describe methods for acquiring and processing 4D data using conventional scanning confocal microscopy. PMID:27631997

  15. The scientific value of 4D visualizations

    NASA Astrophysics Data System (ADS)

    Minster, J.; Olsen, K.; Day, S.; Moore, R.; Jordan, T. H.; Maechling, P.; Chourasia, A.

    2006-12-01

    Significant scientific insights derive from viewing measured, or calculated three-dimensional, time-dependent -- that is four-dimensional-- fields. This issue cuts across all disciplines of Earth Sciences. Addressing it calls for close collaborations between "domain" scientists and "IT" visualization specialists. Techniques to display such 4D fields in a intuitive way are a major challenge, especially when the relevant variables to be displayed are not scalars but tensors. This talk will illustrate some attempts to deal with this challenge, using seismic wave fields as specific objects to display. We will highlight how 4D displays can help address very difficult issues of significant scientific import.

  16. Update on three-dimensional image reconstruction for preoperative simulation in thoracic surgery

    PubMed Central

    Chen-Yoshikawa, Toyofumi F.

    2016-01-01

    Background Three-dimensional computed tomography (3D-CT) technologies have been developed and refined over time. Recently, high-speed and high-quality 3D-CT technologies have also been introduced to the field of thoracic surgery. The purpose of this manuscript is to demonstrate several examples of these 3D-CT technologies in various scenarios in thoracic surgery. Methods A newly-developed high-speed and high-quality 3D image analysis software system was used in Kyoto University Hospital. Simulation and/or navigation were performed using this 3D-CT technology in various thoracic surgeries. Results Preoperative 3D-CT simulation was performed in most patients undergoing video-assisted thoracoscopic surgery (VATS). Anatomical variation was frequently detected preoperatively, which was useful in performing VATS procedures when using only a monitor for vision. In sublobar resection, 3D-CT simulation was more helpful. In small lung lesions, which were supposedly neither visible nor palpable, preoperative marking of the lesions was performed using 3D-CT simulation, and wedge resection or segmentectomy was successfully performed with confidence. This technique also enabled virtual-reality endobronchial ultrasonography (EBUS), which made the procedure more safe and reliable. Furthermore, in living-donor lobar lung transplantation (LDLLT), surgical procedures for donor lobectomy were simulated preoperatively by 3D-CT angiography, which also affected surgical procedures for recipient surgery. New surgical techniques such as right and left inverted LDLLT were also established using 3D models created with this technique. Conclusions After the introduction of 3D-CT technology to the field of thoracic surgery, preoperative simulation has been developed for various thoracic procedures. In the near future, this technique will become more common in thoracic surgery, and frequent use by thoracic surgeons will be seen in worldwide daily practice. PMID:27014477

  17. 4D-Var Developement at GMAO

    NASA Technical Reports Server (NTRS)

    Pelc, Joanna S.; Todling, Ricardo; Akkraoui, Amal El

    2014-01-01

    The Global Modeling and Assimilation Offce (GMAO) is currently using an IAU-based 3D-Var data assimilation system. GMAO has been experimenting with a 3D-Var-hybrid version of its data assimilation system (DAS) for over a year now, which will soon become operational and it will rapidly progress toward a 4D-EnVar. Concurrently, the machinery to exercise traditional 4DVar is in place and it is desirable to have a comparison of the traditional 4D approach with the other available options, and evaluate their performance in the Goddard Earth Observing System (GEOS) DAS. This work will also explore the possibility for constructing a reduced order model (ROM) to make traditional 4D-Var computationally attractive for increasing model resolutions. Part of the research on ROM will be to search for a suitably acceptable space to carry on the corresponding reduction. This poster illustrates how the IAU-based 4D-Var assimilation compares with our currently used IAU-based 3D-Var.

  18. Clinical evaluation of 4D PET motion compensation strategies for treatment verification in ion beam therapy

    NASA Astrophysics Data System (ADS)

    Gianoli, Chiara; Kurz, Christopher; Riboldi, Marco; Bauer, Julia; Fontana, Giulia; Baroni, Guido; Debus, Jürgen; Parodi, Katia

    2016-06-01

    A clinical trial named PROMETHEUS is currently ongoing for inoperable hepatocellular carcinoma (HCC) at the Heidelberg Ion Beam Therapy Center (HIT, Germany). In this framework, 4D PET-CT datasets are acquired shortly after the therapeutic treatment to compare the irradiation induced PET image with a Monte Carlo PET prediction resulting from the simulation of treatment delivery. The extremely low count statistics of this measured PET image represents a major limitation of this technique, especially in presence of target motion. The purpose of the study is to investigate two different 4D PET motion compensation strategies towards the recovery of the whole count statistics for improved image quality of the 4D PET-CT datasets for PET-based treatment verification. The well-known 4D-MLEM reconstruction algorithm, embedding the motion compensation in the reconstruction process of 4D PET sinograms, was compared to a recently proposed pre-reconstruction motion compensation strategy, which operates in sinogram domain by applying the motion compensation to the 4D PET sinograms. With reference to phantom and patient datasets, advantages and drawbacks of the two 4D PET motion compensation strategies were identified. The 4D-MLEM algorithm was strongly affected by inverse inconsistency of the motion model but demonstrated the capability to mitigate the noise-break-up effects. Conversely, the pre-reconstruction warping showed less sensitivity to inverse inconsistency but also more noise in the reconstructed images. The comparison was performed by relying on quantification of PET activity and ion range difference, typically yielding similar results. The study demonstrated that treatment verification of moving targets could be accomplished by relying on the whole count statistics image quality, as obtained from the application of 4D PET motion compensation strategies. In particular, the pre-reconstruction warping was shown to represent a promising choice when combined with intra

  19. Clinical evaluation of 4D PET motion compensation strategies for treatment verification in ion beam therapy.

    PubMed

    Gianoli, Chiara; Kurz, Christopher; Riboldi, Marco; Bauer, Julia; Fontana, Giulia; Baroni, Guido; Debus, Jürgen; Parodi, Katia

    2016-06-01

    A clinical trial named PROMETHEUS is currently ongoing for inoperable hepatocellular carcinoma (HCC) at the Heidelberg Ion Beam Therapy Center (HIT, Germany). In this framework, 4D PET-CT datasets are acquired shortly after the therapeutic treatment to compare the irradiation induced PET image with a Monte Carlo PET prediction resulting from the simulation of treatment delivery. The extremely low count statistics of this measured PET image represents a major limitation of this technique, especially in presence of target motion. The purpose of the study is to investigate two different 4D PET motion compensation strategies towards the recovery of the whole count statistics for improved image quality of the 4D PET-CT datasets for PET-based treatment verification. The well-known 4D-MLEM reconstruction algorithm, embedding the motion compensation in the reconstruction process of 4D PET sinograms, was compared to a recently proposed pre-reconstruction motion compensation strategy, which operates in sinogram domain by applying the motion compensation to the 4D PET sinograms. With reference to phantom and patient datasets, advantages and drawbacks of the two 4D PET motion compensation strategies were identified. The 4D-MLEM algorithm was strongly affected by inverse inconsistency of the motion model but demonstrated the capability to mitigate the noise-break-up effects. Conversely, the pre-reconstruction warping showed less sensitivity to inverse inconsistency but also more noise in the reconstructed images. The comparison was performed by relying on quantification of PET activity and ion range difference, typically yielding similar results. The study demonstrated that treatment verification of moving targets could be accomplished by relying on the whole count statistics image quality, as obtained from the application of 4D PET motion compensation strategies. In particular, the pre-reconstruction warping was shown to represent a promising choice when combined with intra

  20. [Thoracic outlet syndrome].

    PubMed

    Rodriguez, José Maria

    2005-01-01

    The thoracic outlet syndrome is a polymorphic clinical entity, whose nature is essentially anatomic, caused by the chronic compression of the neurovascular structures that are originated in the chest or neck and course to the upper extremity. According to the most affected structure, they can be classified as neurologic, arterial or venous syndromes, that may cause discomfort, pain and disability, sometimes definite and irreparable. Thoracic outlet syndrome are often difficult to recognize in clinical practice and it is important to emphasize some peculiar symptoms or signs that each syndrome may present, through specific maneuvers or adequate complementary studies. The great majority of patients may improve with physical therapy or postural correction, and a minority is indicated for surgical therapy. The main features of the diverse thoracic outlet syndromes, their clinical presentation, diagnosis, conventional and surgical management, surgical access, complications and prognosis are described and discussed in this paper dedicated to a complete review of the entity. PMID:16234911

  1. A randomized controlled trial on the efficacy of thoracic CT screening for lung cancer in non-smokers and smokers of <30 pack-years aged 50-64 years (JECS study): research design.

    PubMed

    Sagawa, Motoyasu; Nakayama, Tomio; Tanaka, Makoto; Sakuma, Tsutomu; Sobue, Tomotaka

    2012-12-01

    In order to assess the efficacy of lung cancer screening using low-dose thoracic computed tomography, compared with chest roentgenography, in people aged 50-64 years with a smoking history of <30 pack-years, a randomized controlled trial is being conducted in Japan. The screening methods are randomly assigned individually. The duration of this trial is 10 years. In the intervention arm, low-dose thoracic computed tomography is performed for each participant in the first and the sixth years. In the control arm, chest roentgenography is performed for each participant in the first year. The participants in both arms are also encouraged to receive routine lung cancer screening using chest roentgenography annually. The interpretation of radiological findings and the follow-up of undiagnosed nodules are to be carried out according to the guidelines published in Japan. The required sample size is calculated to be 17 500 subjects for each arm.

  2. Thoracic spine x-ray

    MedlinePlus

    Vertebral radiography; X-ray - spine; Thoracic x-ray; Spine x-ray; Thoracic spine films; Back films ... care provider's office. You will lie on the x-ray table in different positions. If the x-ray ...

  3. SU-E-J-06: A Feasibility Study On Clinical Implementation of 4D-CBCT in Lung Cancer Treatment

    SciTech Connect

    Hu, Y; Stanford, J; Duggar, W; Ruan, C; He, R; Yang, C

    2014-06-01

    Purpose: Four-dimensional cone-beam CT (4D-CBCT) is a novel imaging technique to setup patients with pulmonary lesions in radiation therapy. This paper is to perform a feasibility study on the implementation of 4D-CBCT as image guidance for (1) SBRT and (2) Low Modulation (Low-Mod) IMRT in lung cancer treatment. Methods: Image artifacts and observers variability are evaluated by analyzing the 4D-CT QA phantom and patient 4D image data. There are two 4D-CBCT image artifacts: (1) Spatial artifact caused by the patient irregular breathing pattern will generate blurring and anatomy gap/overlap; (2) Cone beam scattering and hardening artifact will affect the image spatial and contrast resolution. The couch shift varies between 1mm to 3mm from different observers during the 4D-CBCT registration. Breath training is highly recommended to improve the respiratory regularity during CT simulation and treatment, especially for SBRT. Elekta XVI 4.5 Symmetry protocol is adopted in the patient 4DCBCT scanning and intensity-based registration. Physician adjustments on the auto-registration are involved prior to the treatment. Physician peer review on 4D-CBCT image acquisition and registration is also recommended to reduce the inter-observer variability. The average 4D-CT in reference volume coordinates is exported to MIM Vista 5.6.2 to manually fuse to the planning CT for further evaluation. Results: (1) SBRT: 4DCBCT is performed in dry-run and in each treatment fraction. Image registration and couch shift are reviewed by another physician on the 1st fraction before the treatment starts. (2) Low-Mod IMRT: 4D-CBCT is performed and peer reviewed on weekly basis. Conclusion: 4D-CBCT in SBRT dry-run can discover the ITV discrepancies caused by the low quality 4D-CT simulation. 4D-CBCT during SBRT and Low-Mod IMRT treatment provides physicians more confidence to target lung tumor and capability to evaluate inter-fractional ITV changes. More advanced 4D-CBCT scan protocol and

  4. Comparison of {sup 18}F-Fluorothymidine and {sup 18}F-Fluorodeoxyglucose PET/CT in Delineating Gross Tumor Volume by Optimal Threshold in Patients With Squamous Cell Carcinoma of Thoracic Esophagus

    SciTech Connect

    Han Dali; Yu Jinming; Yu Yonghua; Zhang Guifang; Zhong Xiaojun; Lu Jie; Yin Yong; Fu Zheng; Mu Dianbin; Zhang Baijiang; He Wei; Huo Zhijun; Liu Xijun; Kong Lei; Zhao Shuqiang; Sun Xiangyu

    2010-03-15

    Purpose: To determine the optimal method of using {sup 18}F-fluorothymidine (FLT) positron emission tomography (PET)/computed tomography (CT) simulation to delineate the gross tumor volume (GTV) in esophageal squamous cell carcinoma verified by pathologic examination and compare the results with those using {sup 18}F-fluorodeoxyglucose (FDG) PET/CT. Methods and Materials: A total of 22 patients were enrolled and underwent both FLT and FDG PET/CT. The GTVs with biologic information were delineated using seven different methods in FLT PET/CT and three different methods in FDG PET/CT. The results were compared with the pathologic gross tumor length, and the optimal threshold was obtained. Next, we compared the simulation plans using the optimal threshold of FLT and FDG PET/CT. The radiation dose was prescribed as 60 Gy in 30 fractions with a precise radiotherapy technique. Results: The mean +- standard deviation pathologic gross tumor length was 4.94 +- 2.21 cm. On FLT PET/CT, the length of the standardized uptake value 1.4 was 4.91 +- 2.43 cm. On FDG PET/CT, the length of the standardized uptake value 2.5 was 5.10 +- 2.18 cm, both of which seemed more approximate to the pathologic gross tumor length. The differences in the bilateral lung volume receiving >=20 Gy, heart volume receiving >=40 Gy, and the maximal dose received by spinal cord between FLT and FDG were not significant. However, the values for mean lung dose, bilateral lung volume receiving >=5, >=10, >=30, >=40, and >=50 Gy, mean heart dose, and heart volume receiving >=30 Gy using FLT PET/CT-based planning were significant lower than those using FDG PET/CT. Conclusion: A standardized uptake value cutoff of 1.4 on FLT PET/CT and one of 2.5 on FDG PET/CT provided the closest estimation of GTV length. Finally, FLT PET/CT-based treatment planning provided potential benefits to the lungs and heart.

  5. Interactive animation of 4D performance capture.

    PubMed

    Casas, Dan; Tejera, Margara; Guillemaut, Jean-Yves; Hilton, Adrian

    2013-05-01

    A 4D parametric motion graph representation is presented for interactive animation from actor performance capture in a multiple camera studio. The representation is based on a 4D model database of temporally aligned mesh sequence reconstructions for multiple motions. High-level movement controls such as speed and direction are achieved by blending multiple mesh sequences of related motions. A real-time mesh sequence blending approach is introduced, which combines the realistic deformation of previous nonlinear solutions with efficient online computation. Transitions between different parametric motion spaces are evaluated in real time based on surface shape and motion similarity. Four-dimensional parametric motion graphs allow real-time interactive character animation while preserving the natural dynamics of the captured performance.

  6. Nondipole Effects in Xe 4d Photoemission

    SciTech Connect

    Hemmers, O; Guillemin, R; Wolska, A; Lindle, D W; Rolles, D; Cheng, K T; Johnson, W R; Zhou, H L; Manson, S T

    2004-07-14

    We measured the nondipole parameters for the spin-orbit doublets Xe 4d{sub 5/2} and Xe 4d{sub 3/2} over a photon-energy range from 100 eV to 250 eV at beamline 8.0.1.3 of the Advanced Light Source at the Lawrence Berkeley National Laboratory. Significant nondipole effects are found at relatively low energies as a result of Cooper minima in dipole channels and interchannel coupling in quadrupole channels. Most importantly, sharp disagreement between experiment and theory, when otherwise excellent agreement was expected, has provided the first evidence of satellite two-electron quadrupole photoionization transitions, along with their crucial importance for a quantitatively accurate theory.

  7. Interactive animation of 4D performance capture.

    PubMed

    Casas, Dan; Tejera, Margara; Guillemaut, Jean-Yves; Hilton, Adrian

    2013-05-01

    A 4D parametric motion graph representation is presented for interactive animation from actor performance capture in a multiple camera studio. The representation is based on a 4D model database of temporally aligned mesh sequence reconstructions for multiple motions. High-level movement controls such as speed and direction are achieved by blending multiple mesh sequences of related motions. A real-time mesh sequence blending approach is introduced, which combines the realistic deformation of previous nonlinear solutions with efficient online computation. Transitions between different parametric motion spaces are evaluated in real time based on surface shape and motion similarity. Four-dimensional parametric motion graphs allow real-time interactive character animation while preserving the natural dynamics of the captured performance. PMID:23492379

  8. Thoracic outlet syndrome: anatomy.

    PubMed

    Atasoy, Erdoğan

    2004-02-01

    The thoracic outlet region contains three important structures: the brachial plexus, the subclavian artery, and the subclavian vein. As they travel from the upper mediastinum to the upper extremity, these structures run through three important spaces: the interscalene triangle, the costoclavicular space, and the subpectoral space. Compression can occur in any of these three spaces because of structural anomalies or trauma.

  9. Imaging features of thoracic metastases from gynecologic neoplasms.

    PubMed

    Martínez-Jiménez, Santiago; Rosado-de-Christenson, Melissa L; Walker, Christopher M; Kunin, Jeffery R; Betancourt, Sonia L; Shoup, Brenda L; Pettavel, Paul P

    2014-10-01

    Gynecologic malignancies are a heterogeneous group of common neoplasms and represent the fourth most common malignancy in women. Thoracic metastases exhibit various imaging patterns and are usually associated with locally invasive primary neoplasms with intra-abdominal spread. However, thoracic involvement may also occur many months to years after initial diagnosis or as an isolated finding in patients without evidence of intra-abdominal neoplastic involvement. Thoracic metastases from endometrial carcinoma typically manifest as pulmonary nodules and lymphadenopathy. Thoracic metastases from ovarian cancer often manifest with small pleural effusions and subtle pleural nodules. Thoracic metastases to the lungs, lymph nodes, and pleura may also exhibit calcification and mimic granulomatous disease. Metastases from fallopian tube carcinomas exhibit imaging features identical to those of ovarian cancers. Most cervical cancers are of squamous histology, and while solid pulmonary metastases are more common, cavitary metastases occur with some frequency. Metastatic choriocarcinoma to the lung characteristically manifests with solid pulmonary nodules. Some pulmonary metastases from gynecologic malignancies exhibit characteristic features such as cavitation (in squamous cell cervical cancer) and the "halo" sign (in hemorrhagic metastatic choriocarcinoma) at computed tomography (CT). However, metastases from common gynecologic malignancies may be subtle and indolent and may mimic benign conditions such as intrapulmonary lymph nodes and remote granulomatous disease. Therefore, radiologists should consider the presence of locoregional disease as well as elevated tumor marker levels when interpreting imaging studies because subtle imaging findings may represent metastatic disease. Positron emission tomography/CT may be helpful in identifying early locoregional and distant tumor spread. PMID:25310428

  10. Impact of 4D image quality on the accuracy of target definition.

    PubMed

    Nielsen, Tine Bjørn; Hansen, Christian Rønn; Westberg, Jonas; Hansen, Olfred; Brink, Carsten

    2016-03-01

    Delineation accuracy of target shape and position depends on the image quality. This study investigates whether the image quality on standard 4D systems has an influence comparable to the overall delineation uncertainty. A moving lung target was imaged using a dynamic thorax phantom on three different 4D computed tomography (CT) systems and a 4D cone beam CT (CBCT) system using pre-defined clinical scanning protocols. Peak-to-peak motion and target volume were registered using rigid registration and automatic delineation, respectively. A spatial distribution of the imaging uncertainty was calculated as the distance deviation between the imaged target and the true target shape. The measured motions were smaller than actual motions. There were volume differences of the imaged target between respiration phases. Imaging uncertainties of >0.4 cm were measured in the motion direction which showed that there was a large distortion of the imaged target shape. Imaging uncertainties of standard 4D systems are of similar size as typical GTV-CTV expansions (0.5-1 cm) and contribute considerably to the target definition uncertainty. Optimising and validating 4D systems is recommended in order to obtain the most optimal imaged target shape.

  11. Mediastinal thoracic duct cyst.

    PubMed Central

    Gowar, F J

    1978-01-01

    A case of mediastinal thoracic duct cyst is described; it is believed to be the first to be reported in Britain. Five surgically treated cases have been reported but in none was the diagnosis made before operation. Symptoms are caused by pressure of the cyst on the trachea and oesophagus and my be aggravted by eating a fatty meal. Differential diagnosis from other mediastinal tumours, especially bronchogenic cyst and neurofibroma, could perhaps be established before operation by lymphangiography. Images PMID:746509

  12. Active origami by 4D printing

    NASA Astrophysics Data System (ADS)

    Ge, Qi; Dunn, Conner K.; Qi, H. Jerry; Dunn, Martin L.

    2014-09-01

    Recent advances in three dimensional (3D) printing technology that allow multiple materials to be printed within each layer enable the creation of materials and components with precisely controlled heterogeneous microstructures. In addition, active materials, such as shape memory polymers, can be printed to create an active microstructure within a solid. These active materials can subsequently be activated in a controlled manner to change the shape or configuration of the solid in response to an environmental stimulus. This has been termed 4D printing, with the 4th dimension being the time-dependent shape change after the printing. In this paper, we advance the 4D printing concept to the design and fabrication of active origami, where a flat sheet automatically folds into a complicated 3D component. Here we print active composites with shape memory polymer fibers precisely printed in an elastomeric matrix and use them as intelligent active hinges to enable origami folding patterns. We develop a theoretical model to provide guidance in selecting design parameters such as fiber dimensions, hinge length, and programming strains and temperature. Using the model, we design and fabricate several active origami components that assemble from flat polymer sheets, including a box, a pyramid, and two origami airplanes. In addition, we directly print a 3D box with active composite hinges and program it to assume a temporary flat shape that subsequently recovers to the 3D box shape on demand.

  13. Pitfalls in CT recognition of mediastinal lymphadenopathy

    SciTech Connect

    Glazer, H.S.; Aronberg, D.J.; Sagel, S.S.

    1985-02-01

    Computed tomography (CT) has become the most accurate radiologic technique for the evaluation of mediastinal lymph nodes. Since the introduction of thoracic CT, a variety of anatomic structures, both normal and aberrant, have been described that can be confused with enlarged mediastinal lymph nodes; these represent potential diagnostic pitfalls. This essay illustrates many of these structures and distinguish them from abnormal lymph nodes.

  14. [Surgery for thoracic tuberculosis].

    PubMed

    Kilani, T; Boudaya, M S; Zribi, H; Ouerghi, S; Marghli, A; Mestiri, T; Mezni, F

    2015-01-01

    Tuberculosis is mainly a medical disease. Surgery has been the unique therapeutic tool for a long time before the advent of specific antituberculous drugs, and the role of surgery was then confined to the treatment of the sequelae of tuberculosis and their complications. The resurgence of tuberculosis and the emergence of multidrug-resistant TB combined to immunosuppressed patients represent a new challenge for tuberculosis surgery. Surgery may be indicated for a diagnostic purpose in patients with pulmonary, pleural, mediastinal or thoracic wall involvement, or with a therapeutic purpose (drainage, resection, residual cavity obliteration). Modern imaging techniques and the advent of video-assisted thoracic surgery allowed a new approach of this pathology; the majority of diagnostic interventions and selected cases requiring lung resection can be performed through a mini-invasive approach. Patients proposed for aggressive surgery may be treated with the best results thanks to a good evaluation of the thoracic lesions, of the patients' nutritional, infectious and general status combined with a good coordination between the specialized medical team for an optimal preparation to surgery.

  15. [Thoracic actinomycosis: three cases].

    PubMed

    Herrak, L; Msougar, Y; Ouadnouni, Y; Bouchikh, M; Benosmane, A

    2007-09-01

    Actinomycosis is a rare condition which, in the thoracic localisation, can mimic cancer or tuberculosis. We report a series of three case of thoracic actinomycosis treated in the Ibn Sina University Thoracic Surgery Unit in Rabat, Morocco. CASE N degrees 1: This 45-year-old patient presented a tumefaction on the left anterior aspect of the chest. Physical examination identified a parietal mass with fistulisation to the skin. Radiography demonstrated a left pulmonary mass. Transparietal puncture led to the pathological diagnosis of actinomycosis. The patient was given medical treatment and improved clinically and radiographically. CASE N degrees 2: This 68-year-old patient presented repeated episodes of hemoptysis. The chest x-ray revealed atelectasia of the middle lobe and bronchial fibroscopy demonstrated the presence of a bud in the middle lobar bronchus. Biopsies were negative. The patient underwent surgery and the histology examination of the operative specimen revealed pulmonary actinomycosis. The patient recovered well clinically and radiographically with antibiotic therapy. CASE N degrees 3: This 56-year-old patient presented cough and hemoptysis. Physical examination revealed a left condensation and destruction of the left lung was noted on the chest x-ray. Left pleuropulmonectomy was performed. Histological analysis of the surgical specimen identified associated Aspergillus and Actinomyces. The outcome was favorable with medical treatment. The purpose of this work was to recall the radiological, clinical, histological, therapeutic, outcome aspects of this condition and to relate the problems of differential diagnosis when can suggest other diseases. PMID:17978739

  16. Impact of temporal probability in 4D dose calculation for lung tumors.

    PubMed

    Rouabhi, Ouided; Ma, Mingyu; Bayouth, John; Xia, Junyi

    2015-11-08

    The purpose of this study was to evaluate the dosimetric uncertainty in 4D dose calculation using three temporal probability distributions: uniform distribution, sinusoidal distribution, and patient-specific distribution derived from the patient respiratory trace. Temporal probability, defined as the fraction of time a patient spends in each respiratory amplitude, was evaluated in nine lung cancer patients. Four-dimensional computed tomography (4D CT), along with deformable image registration, was used to compute 4D dose incorporating the patient's respiratory motion. First, the dose of each of 10 phase CTs was computed using the same planning parameters as those used in 3D treatment planning based on the breath-hold CT. Next, deformable image registration was used to deform the dose of each phase CT to the breath-hold CT using the deformation map between the phase CT and the breath-hold CT. Finally, the 4D dose was computed by summing the deformed phase doses using their corresponding temporal probabilities. In this study, 4D dose calculated from the patient-specific temporal probability distribution was used as the ground truth. The dosimetric evaluation matrix included: 1) 3D gamma analysis, 2) mean tumor dose (MTD), 3) mean lung dose (MLD), and 4) lung V20. For seven out of nine patients, both uniform and sinusoidal temporal probability dose distributions were found to have an average gamma passing rate > 95% for both the lung and PTV regions. Compared with 4D dose calculated using the patient respiratory trace, doses using uniform and sinusoidal distribution showed a percentage difference on average of -0.1% ± 0.6% and -0.2% ± 0.4% in MTD, -0.2% ± 1.9% and -0.2% ± 1.3% in MLD, 0.09% ± 2.8% and -0.07% ± 1.8% in lung V20, -0.1% ± 2.0% and 0.08% ± 1.34% in lung V10, 0.47% ± 1.8% and 0.19% ± 1.3% in lung V5, respectively. We concluded that four-dimensional dose computed using either a uniform or sinusoidal temporal probability distribution can

  17. [Paravertebral analgesia in thoracic surgery].

    PubMed

    Arnal, D; Garutti, I; Olmedilla, L

    2004-10-01

    Managing postoperative pain from thoracotomy is one of the greatest challenges anesthesiologists face in daily practice. Proper management is assumed to improve the patient's prognosis. The thoracic paravertebral block, following its rediscovery, is being used with increasing frequency and success for both surgery and recovery from thoracotomy, challenging the supremacy of thoracic epidural analgesia, which to date has been considered the gold standard. We describe the history, anatomy, techniques and complications of the thoracic paravertebral block and review published randomized controlled trials comparing the thoracic paravertebral block to placebo and to epidural analgesia. In view of published evidence, it seems that the thoracic paravertebral block may replace the thoracic epidural technique as the gold standard for providing analgesia for patients undergoing thoracotomy.

  18. Nonmalignant Adult Thoracic Lymphatic Disorders.

    PubMed

    Itkin, Maxim; McCormack, Francis X

    2016-09-01

    The thoracic lymphatic disorders are a heterogeneous group of uncommon conditions that are associated with thoracic masses, interstitial pulmonary infiltrates, and chylous complications. Accurate diagnosis of the thoracic lymphatic disorders has important implications for the newest approaches to management, including embolization and treatment with antilymphangiogenic drugs. New imaging techniques to characterize lymphatic flow, such as dynamic contrast-enhanced magnetic resonance lymphangiogram, are redefining approaches to disease classification and therapy. PMID:27514588

  19. Nonintubated anesthesia for thoracic surgery

    PubMed Central

    Wang, Bei

    2014-01-01

    Nonintubated thoracic surgery has been used in procedures including pleura, lungs and mediastinum. Appropriate anesthesia techniques with or without sedation allow thoracic surgery patients to avoid the potential risks of intubated general anesthesia, particularly for the high-risk patients. However, nonintubated anesthesia for thoracic surgery has some benefits as well as problems. In this review, the background, indication, perioperative anesthetic consideration and management, and advantages and disadvantages are discussed and summarized. PMID:25589994

  20. ICT4D: A Computer Science Perspective

    NASA Astrophysics Data System (ADS)

    Sutinen, Erkki; Tedre, Matti

    The term ICT4D refers to the opportunities of Information and Communication Technology (ICT) as an agent of development. Research in that field is often focused on evaluating the feasibility of existing technologies, mostly of Western or Far East Asian origin, in the context of developing regions. A computer science perspective is complementary to that agenda. The computer science perspective focuses on exploring the resources, or inputs, of a particular context and on basing the design of a technical intervention on the available resources, so that the output makes a difference in the development context. The modus operandi of computer science, construction, interacts with evaluation and exploration practices. An analysis of a contextualized information technology curriculum of Tumaini University in southern Tanzania shows the potential of the computer science perspective for designing meaningful information and communication technology for a developing region.

  1. 4D Clinical Imaging for Dynamic CAD

    PubMed Central

    McIntyre, Frederick

    2013-01-01

    A basic 4D imaging system to capture the jaw motion has been developed that produces high resolution 3D surface data. Fluorescent microspheres are brushed onto the areas of the upper and the lower arches to be imaged, producing a high-contrast random optical pattern. A hand-held imaging device operated at about 10 cm from the mouth captures time-based perspective images of the fluorescent areas. Each set of images, containing both upper and the lower arch data, is converted to a 3d point mesh using photogrammetry, thereby providing an instantaneous relative jaw position. Eight 3d positions per second are captured. Using one of the 3d frames as a reference, incremental transforms are derived to express the free body motion of the mandible. Conventional 3d models of the dentition are directly registered to the reference frame, allowing them to be animated using the derived transforms. PMID:24082882

  2. Soft Route to 4D Tomography.

    PubMed

    Taillandier-Thomas, Thibault; Roux, Stéphane; Hild, François

    2016-07-01

    Based on the assumption that the time evolution of a sample observed by computed tomography requires many less parameters than the definition of the microstructure itself, it is proposed to reconstruct these changes based on the initial state (using computed tomography) and very few radiographs acquired at fixed intervals of time. This Letter presents a proof of concept that for a fatigue cracked sample its kinematics can be tracked from no more than two radiographs in situations where a complete 3D view would require several hundreds of radiographs. This 2 order of magnitude gain opens the way to a "computed" 4D tomography, which complements the recent progress achieved in fast or ultrafast computed tomography, which is based on beam brightness, detector sensitivity, and signal acquisition technologies.

  3. Soft Route to 4D Tomography

    NASA Astrophysics Data System (ADS)

    Taillandier-Thomas, Thibault; Roux, Stéphane; Hild, François

    2016-07-01

    Based on the assumption that the time evolution of a sample observed by computed tomography requires many less parameters than the definition of the microstructure itself, it is proposed to reconstruct these changes based on the initial state (using computed tomography) and very few radiographs acquired at fixed intervals of time. This Letter presents a proof of concept that for a fatigue cracked sample its kinematics can be tracked from no more than two radiographs in situations where a complete 3D view would require several hundreds of radiographs. This 2 order of magnitude gain opens the way to a "computed" 4D tomography, which complements the recent progress achieved in fast or ultrafast computed tomography, which is based on beam brightness, detector sensitivity, and signal acquisition technologies.

  4. Image segmentation and registration algorithm to collect thoracic skeleton semilandmarks for characterization of age and sex-based thoracic morphology variation.

    PubMed

    Weaver, Ashley A; Nguyen, Callistus M; Schoell, Samantha L; Maldjian, Joseph A; Stitzel, Joel D

    2015-12-01

    Thoracic anthropometry variations with age and sex have been reported and likely relate to thoracic injury risk and outcome. The objective of this study was to collect a large volume of homologous semilandmark data from the thoracic skeleton for the purpose of quantifying thoracic morphology variations for males and females of ages 0-100 years. A semi-automated image segmentation and registration algorithm was applied to collect homologous thoracic skeleton semilandmarks from 343 normal computed tomography (CT) scans. Rigid, affine, and symmetric diffeomorphic transformations were used to register semilandmarks from an atlas to homologous locations in the subject-specific coordinate system. Homologous semilandmarks were successfully collected from 92% (7077) of the ribs and 100% (187) of the sternums included in the study. Between 2700 and 11,000 semilandmarks were collected from each rib and sternum and over 55 million total semilandmarks were collected from all subjects. The extensive landmark data collected more fully characterizes thoracic skeleton morphology across ages and sexes. Characterization of thoracic morphology with age and sex may help explain variations in thoracic injury risk and has important implications for vulnerable populations such as pediatrics and the elderly.

  5. Opening the Black Box of ICT4D: Advancing Our Understanding of ICT4D Partnerships

    ERIC Educational Resources Information Center

    Park, Sung Jin

    2013-01-01

    The term, Information and Communication Technologies for Development (ICT4D), pertains to programs or projects that strategically use ICTs (e.g. mobile phones, computers, and the internet) as a means toward the socio-economic betterment for the poor in developing contexts. Gaining the political and financial support of the international community…

  6. Exome sequencing identifies PDE4D mutations as another cause of acrodysostosis.

    PubMed

    Michot, Caroline; Le Goff, Carine; Goldenberg, Alice; Abhyankar, Avinash; Klein, Céline; Kinning, Esther; Guerrot, Anne-Marie; Flahaut, Philippe; Duncombe, Alice; Baujat, Genevieve; Lyonnet, Stanislas; Thalassinos, Caroline; Nitschke, Patrick; Casanova, Jean-Laurent; Le Merrer, Martine; Munnich, Arnold; Cormier-Daire, Valérie

    2012-04-01

    Acrodysostosis is a rare autosomal-dominant condition characterized by facial dysostosis, severe brachydactyly with cone-shaped epiphyses, and short stature. Moderate intellectual disability and resistance to multiple hormones might also be present. Recently, a recurrent mutation (c.1102C>T [p.Arg368*]) in PRKAR1A has been identified in three individuals with acrodysostosis and resistance to multiple hormones. After studying ten unrelated acrodysostosis cases, we report here de novo PRKAR1A mutations in five out of the ten individuals (we found c.1102C>T [p.Arg368(∗)] in four of the ten and c.1117T>C [p.Tyr373His] in one of the ten). We performed exome sequencing in two of the five remaining individuals and selected phosphodiesterase 4D (PDE4D) as a candidate gene. PDE4D encodes a class IV cyclic AMP (cAMP)-specific phosphodiesterase that regulates cAMP concentration. Exome analysis detected heterozygous PDE4D mutations (c.673C>A [p.Pro225Thr] and c.677T>C [p.Phe226Ser]) in these two individuals. Screening of PDE4D identified heterozygous mutations (c.568T>G [p.Ser190Ala] and c.1759A>C [p.Thr587Pro]) in two additional acrodysostosis cases. These mutations occurred de novo in all four cases. The four individuals with PDE4D mutations shared common clinical features, namely characteristic midface and nasal hypoplasia and moderate intellectual disability. Metabolic screening was normal in three of these four individuals. However, resistance to parathyroid hormone and thyrotropin was consistently observed in the five cases with PRKAR1A mutations. Finally, our study further supports the key role of the cAMP signaling pathway in skeletogenesis. PMID:22464250

  7. Aneurysms: thoracic aortic aneurysms.

    PubMed

    Chun, Kevin C; Lee, Eugene S

    2015-04-01

    Thoracic aortic aneurysms (TAAs) have many possible etiologies, including congenital heart defects (eg, bicuspid aortic valves, coarctation of the aorta), inherited connective tissue disorders (eg, Marfan, Ehlers-Danlos, Loeys-Dietz syndromes), and degenerative conditions (eg, medial necrosis, atherosclerosis of the aortic wall). Symptoms of rupture include a severe tearing pain in the chest, back, or neck, sometimes associated with cardiovascular collapse. Before rupture, TAAs may exert pressure on other thoracic structures, leading to a variety of symptoms. However, most TAAs are asymptomatic and are found incidentally during imaging for other conditions. Diagnosis is confirmed with computed tomography scan or echocardiography. Asymptomatic TAAs should be monitored with imaging at specified intervals and patients referred for repair if the TAAs are enlarging rapidly (greater than 0.5 cm in diameter over 6 months for heritable etiologies; greater than 0.5 cm over 1 year for degenerative etiologies) or reach a critical aortic diameter threshold for elective surgery (5.5 cm for TAAs due to degenerative etiologies, 5.0 cm when associated with inherited syndromes). Open surgery is used most often to treat asymptomatic TAAs in the ascending aorta and aortic arch. Asymptomatic TAAs in the descending aorta often are treated medically with aggressive blood pressure control, though recent data suggest that endovascular procedures may result in better long-term survival rates. PMID:25860136

  8. Thoracic Pedicle Screw Placement Guide Plate Produced by Three-Dimensional (3-D) Laser Printing

    PubMed Central

    Chen, Hongliang; Guo, Kaijing; Yang, Huilin; Wu, Dongying; Yuan, Feng

    2016-01-01

    Background The aim of this study was to evaluate the accuracy and feasibility of an individualized thoracic pedicle screw placement guide plate produced by 3-D laser printing. Material/Methods Thoracic pedicle samples of 3 adult cadavers were randomly assigned for 3-D CT scans. The 3-D thoracic models were established by using medical Mimics software, and a screw path was designed with scanned data. Then the individualized thoracic pedicle screw placement guide plate models, matched to the backside of thoracic vertebral plates, were produced with a 3-D laser printer. Screws were placed with assistance of a guide plate. Then, the placement was assessed. Results With the data provided by CT scans, 27 individualized guide plates were produced by 3-D printing. There was no significant difference in sex and relevant parameters of left and right sides among individuals (P>0.05). Screws were placed with assistance of guide plates, and all screws were in the correct positions without penetration of pedicles, under direct observation and anatomic evaluation post-operatively. Conclusions A thoracic pedicle screw placement guide plate can be produced by 3-D printing. With a high accuracy in placement and convenient operation, it provides a new method for accurate placement of thoracic pedicle screws. PMID:27194139

  9. Thoracic Pedicle Screw Placement Guide Plate Produced by Three-Dimensional (3-D) Laser Printing.

    PubMed

    Chen, Hongliang; Guo, Kaijing; Yang, Huilin; Wu, Dongying; Yuan, Feng

    2016-01-01

    BACKGROUND The aim of this study was to evaluate the accuracy and feasibility of an individualized thoracic pedicle screw placement guide plate produced by 3-D laser printing. MATERIAL AND METHODS Thoracic pedicle samples of 3 adult cadavers were randomly assigned for 3-D CT scans. The 3-D thoracic models were established by using medical Mimics software, and a screw path was designed with scanned data. Then the individualized thoracic pedicle screw placement guide plate models, matched to the backside of thoracic vertebral plates, were produced with a 3-D laser printer. Screws were placed with assistance of a guide plate. Then, the placement was assessed. RESULTS With the data provided by CT scans, 27 individualized guide plates were produced by 3-D printing. There was no significant difference in sex and relevant parameters of left and right sides among individuals (P>0.05). Screws were placed with assistance of guide plates, and all screws were in the correct positions without penetration of pedicles, under direct observation and anatomic evaluation post-operatively. CONCLUSIONS A thoracic pedicle screw placement guide plate can be produced by 3-D printing. With a high accuracy in placement and convenient operation, it provides a new method for accurate placement of thoracic pedicle screws. PMID:27194139

  10. 4-D ultrafast shear-wave imaging.

    PubMed

    Gennisson, Jean-Luc; Provost, Jean; Deffieux, Thomas; Papadacci, Clément; Imbault, Marion; Pernot, Mathieu; Tanter, Mickael

    2015-06-01

    Over the last ten years, shear wave elastography (SWE) has seen considerable development and is now routinely used in clinics to provide mechanical characterization of tissues to improve diagnosis. The most advanced technique relies on the use of an ultrafast scanner to generate and image shear waves in real time in a 2-D plane at several thousands of frames per second. We have recently introduced 3-D ultrafast ultrasound imaging to acquire with matrix probes the 3-D propagation of shear waves generated by a dedicated radiation pressure transducer in a single acquisition. In this study, we demonstrate 3-D SWE based on ultrafast volumetric imaging in a clinically applicable configuration. A 32 × 32 matrix phased array driven by a customized, programmable, 1024-channel ultrasound system was designed to perform 4-D shear-wave imaging. A matrix phased array was used to generate and control in 3-D the shear waves inside the medium using the acoustic radiation force. The same matrix array was used with 3-D coherent plane wave compounding to perform high-quality ultrafast imaging of the shear wave propagation. Volumetric ultrafast acquisitions were then beamformed in 3-D using a delay-and-sum algorithm. 3-D volumetric maps of the shear modulus were reconstructed using a time-of-flight algorithm based on local multiscale cross-correlation of shear wave profiles in the three main directions using directional filters. Results are first presented in an isotropic homogeneous and elastic breast phantom. Then, a full 3-D stiffness reconstruction of the breast was performed in vivo on healthy volunteers. This new full 3-D ultrafast ultrasound system paves the way toward real-time 3-D SWE. PMID:26067040

  11. Vessels as 4-D curves: global minimal 4-D paths to extract 3-D tubular surfaces and centerlines.

    PubMed

    Li, Hua; Yezzi, Anthony

    2007-09-01

    In this paper, we propose an innovative approach to the segmentation of tubular structures. This approach combines all of the benefits of minimal path techniques such as global minimizers, fast computation, and powerful incorporation of user input, while also having the capability to represent and detect vessel surfaces directly which so far has been a feature restricted to active contour and surface techniques. The key is to represent the trajectory of a tubular structure not as a 3-D curve but to go up a dimension and represent the entire structure as a 4-D curve. Then we are able to fully exploit minimal path techniques to obtain global minimizing trajectories between two user supplied endpoints in order to reconstruct tubular structures from noisy or low contrast 3-D data without the sensitivity to local minima inherent in most active surface techniques. In contrast to standard purely spatial 3-D minimal path techniques, however, we are able to represent a full tubular surface rather than just a curve which runs through its interior. Our representation also yields a natural notion of a tube's "central curve." We demonstrate and validate the utility of this approach on magnetic resonance (MR) angiography and computed tomography (CT) images of coronary arteries. PMID:17896594

  12. 17 CFR 260.4d-8 - Content.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 17 Commodity and Securities Exchanges 3 2013-04-01 2013-04-01 false Content. 260.4d-8 Section 260.4d-8 Commodity and Securities Exchanges SECURITIES AND EXCHANGE COMMISSION (CONTINUED) GENERAL RULES AND REGULATIONS, TRUST INDENTURE ACT OF 1939 Rules Under Section 304 § 260.4d-8 Content. (a)...

  13. 17 CFR 260.4d-8 - Content.

    Code of Federal Regulations, 2012 CFR

    2005-04-01

    ... 17 Commodity and Securities Exchanges 3 2005-04-01 2005-04-01 false Content. 260.4d-8 Section 260.4d-8 Commodity and Securities Exchanges SECURITIES AND EXCHANGE COMMISSION (CONTINUED) GENERAL RULES AND REGULATIONS, TRUST INDENTURE ACT OF 1939 Rules Under Section 304 § 260.4d-8 Content. (a)...

  14. 17 CFR 260.4d-8 - Content.

    Code of Federal Regulations, 2013 CFR

    2000-04-01

    ... 17 Commodity and Securities Exchanges 3 2000-04-01 2000-04-01 false Content. 260.4d-8 Section 260.4d-8 Commodity and Securities Exchanges GENERAL RULES AND REGULATIONS, TRUST INDENTURE ACT OF 1939 Rules Under Section 304 § 260.4d-8 Content. (a) Each application for an order under section 304(d)...

  15. 17 CFR 260.4d-8 - Content.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 17 Commodity and Securities Exchanges 3 2011-04-01 2011-04-01 false Content. 260.4d-8 Section 260.4d-8 Commodity and Securities Exchanges SECURITIES AND EXCHANGE COMMISSION (CONTINUED) GENERAL RULES AND REGULATIONS, TRUST INDENTURE ACT OF 1939 Rules Under Section 304 § 260.4d-8 Content. (a)...

  16. 17 CFR 260.4d-8 - Content.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 17 Commodity and Securities Exchanges 3 2012-04-01 2012-04-01 false Content. 260.4d-8 Section 260.4d-8 Commodity and Securities Exchanges SECURITIES AND EXCHANGE COMMISSION (CONTINUED) GENERAL RULES AND REGULATIONS, TRUST INDENTURE ACT OF 1939 Rules Under Section 304 § 260.4d-8 Content. (a)...

  17. 17 CFR 260.4d-8 - Content.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false Content. 260.4d-8 Section 260.4d-8 Commodity and Securities Exchanges SECURITIES AND EXCHANGE COMMISSION (CONTINUED) GENERAL RULES AND REGULATIONS, TRUST INDENTURE ACT OF 1939 Rules Under Section 304 § 260.4d-8 Content. (a)...

  18. 76 FR 55814 - 2,4-D; Pesticide Tolerances

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-09

    ... AGENCY 40 CFR Part 180 2,4-D; Pesticide Tolerances AGENCY: Environmental Protection Agency (EPA). ACTION: Final rule. SUMMARY: This regulation establishes tolerances for residues of 2,4-D in or on teff, bran... 180.142 be amended by establishing a tolerance for residues of the herbicide 2,4-D...

  19. 17 CFR 260.4d-8 - Content.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 17 Commodity and Securities Exchanges 4 2014-04-01 2014-04-01 false Content. 260.4d-8 Section 260.4d-8 Commodity and Securities Exchanges SECURITIES AND EXCHANGE COMMISSION (CONTINUED) GENERAL RULES AND REGULATIONS, TRUST INDENTURE ACT OF 1939 Rules Under Section 304 § 260.4d-8 Content. (a)...

  20. Evaluation of the Elekta Symmetry ™ 4D IGRT system by using a moving lung phantom

    NASA Astrophysics Data System (ADS)

    Shin, Hun-Joo; Kim, Shin-Wook; Kay, Chul Seung; Seo, Jae-Hyuk; Lee, Gi-Woong; Kang, Ki-Mun; Jang, Hong Seok; Kang, Young-nam

    2015-07-01

    Purpose: 4D cone-beam computed tomography (CBCT) is a beneficial tool for the treatment of movable tumors because it can help us to understand where the tumors are actually located and it has a precise treatment plan. However, general CBCT images have a limitation in that they cannot perfectly perform a sophisticated registration. On the other hand, the Symmetry TM 4D image-guided radiation therapy (IGRT) system of Elekta offers a 4D CBCT registration option. In this study, we evaluated the usefulness of Symmetry TM . Method and Materials: Planning CT images of the CIRS moving lung phantom were acquired 4D multi-detector CT (MDCT), and the images were sorted as 10 phases from 0% phase to 90% phase. The thickness of the CT images was 1 mm. Acquired MDCT images were transferred to the contouring software, and a virtual target was generated. A one-arc volumetric-modulated arc therapy (VMAT) plan was performed by using the treatment planning system on the virtual target. Finally, the movement of the phantom was verified by using the XVI Symmetry TM system. Results: The physical movement of the CIRS moving lung phantom was ±10.0 mm in the superiorinferior direction, ±1.0 mm in the lateral direction, and ±2.5 mm in the anterior-posterior direction. The movement of the phantom was measured from the 4D MDCT registration as ±10.2 mm in the superior-inferior direction, ±0.9 mm in the lateral direction, and ±2.45 mm in the anterior-posterior direction. The movement of the phantom was measured from the SymmetryTM registration as ±10.1 mm in the superior-inferior direction, ±0.9 mm in the lateral direction, and ±2.4 mm in the anterior-posterior direction. Conclusion: We confirmed that 4D CBCT is a beneficial tool for the treatment of movable tumors, and that the 4D registration of SymmetryTM can increase the precision of the registration when a movable tumor is the target of radiation treatment.

  1. Thoracic aortopathies in the military patient.

    PubMed

    O'Brien, David; White, S; Wilson, D; Haworth, K; Williams, A

    2015-09-01

    Thoracic aortic disease is an important contributor to arterial disease and therefore, mortality in the UK. It has close associations with hypertension, atherosclerosis and genetic conditions such as Marfan syndrome. The cardiovascular consequences of acute aortic dissection or the rupture of a thoracic aneurysm are life threatening with a 1% increase in mortality per hour with a type A aortic dissection and a high 30-day mortality rate. The clinical diagnosis can be difficult for the general physician as the symptoms can mimic more common conditions such as acute coronary syndrome, pulmonary embolism or acute abdomen. The investigations that carry the highest sensitivity and specificity, CT, transoesophageal echocardiography and MRI are not usually first-line investigations in most patients so a high index of clinical suspicion is key. The management of acute aortic syndromes involves good initial resuscitation and early discussion with the cardiothoracic surgeons. Given the serious consequences of acute aortic syndromes, it is important for all military doctors to be aware of these presentations and to appreciate the difficulties that can be encountered when trying to accurately diagnose them. Routine medicals, particularly entrance medicals, present a unique clinical opportunity to recognise the clinical features that would warrant further investigation and specialist advice. PMID:26243806

  2. Thoracic aortopathies in the military patient.

    PubMed

    O'Brien, David; White, S; Wilson, D; Haworth, K; Williams, A

    2015-09-01

    Thoracic aortic disease is an important contributor to arterial disease and therefore, mortality in the UK. It has close associations with hypertension, atherosclerosis and genetic conditions such as Marfan syndrome. The cardiovascular consequences of acute aortic dissection or the rupture of a thoracic aneurysm are life threatening with a 1% increase in mortality per hour with a type A aortic dissection and a high 30-day mortality rate. The clinical diagnosis can be difficult for the general physician as the symptoms can mimic more common conditions such as acute coronary syndrome, pulmonary embolism or acute abdomen. The investigations that carry the highest sensitivity and specificity, CT, transoesophageal echocardiography and MRI are not usually first-line investigations in most patients so a high index of clinical suspicion is key. The management of acute aortic syndromes involves good initial resuscitation and early discussion with the cardiothoracic surgeons. Given the serious consequences of acute aortic syndromes, it is important for all military doctors to be aware of these presentations and to appreciate the difficulties that can be encountered when trying to accurately diagnose them. Routine medicals, particularly entrance medicals, present a unique clinical opportunity to recognise the clinical features that would warrant further investigation and specialist advice.

  3. Basic thoracic ultrasound for the respiratory physician.

    PubMed

    Jimborean, Gabriela; Ianoşi, Edith Simona; Nemeş, Roxana Maria; Toma, Tudor P

    2015-01-01

    Thoracic ultrasound (TUS) evolved in the last ten years as the method of choice for evaluating pleural abnormalities and for guiding lung procedures. TUS can "see" almost all structures in the chest, including thoracic wall, pleura, pleural space, the heart, the great vessels and the peripheral layers of the lungs. However, there is still a great need to develop TUS services in respiratory departments in Romania. To facilitate this development we reviewed the literature and selected what we considered to be essential practical information for the beginner in TUS, including technique, normal findings, and common abnormalities. Moreover, we describe here a step-by-step scanning technique for chest physicians. Our aim is to raise awareness of TUS. Because TUS is rapid, accurate, noninvasive and can be applied in any ward, we recommend facilitating the training of all junior respiratory doctors in this technique, as it is likely to improve patient experience, clinical effectiveness and to reduce costs with chest radiographs or CT scans in the future. PMID:26738366

  4. Automated contour mapping using sparse volume sampling for 4D radiation therapy

    SciTech Connect

    Chao Ming; Schreibmann, Eduard; Li Tianfang; Wink, Nicole; Xing Lei

    2007-10-15

    The purpose of this work is to develop a novel strategy to automatically map organ contours from one phase of respiration to all other phases on a four-dimensional computed tomography (4D CT). A region of interest (ROI) was manually delineated by a physician on one phase specific image set of a 4D CT. A number of cubic control volumes of the size of {approx}1 cm were automatically placed along the contours. The control volumes were then collectively mapped to the next phase using a rigid transformation. To accommodate organ deformation, a model-based adaptation of the control volume positions was followed after the rigid mapping procedure. This further adjustment of control volume positions was performed by minimizing an energy function which balances the tendency for the control volumes to move to their correspondences with the desire to maintain similar image features and shape integrity of the contour. The mapped ROI surface was then constructed based on the central positions of the control volumes using a triangulated surface construction technique. The proposed technique was assessed using a digital phantom and 4D CT images of three lung patients. Our digital phantom study data indicated that a spatial accuracy better than 2.5 mm is achievable using the proposed technique. The patient study showed a similar level of accuracy. In addition, the computational speed of our algorithm was significantly improved as compared with a conventional deformable registration-based contour mapping technique. The robustness and accuracy of this approach make it a valuable tool for the efficient use of the available spatial-tempo information for 4D simulation and treatment.

  5. 4D electron microscopy: principles and applications.

    PubMed

    Flannigan, David J; Zewail, Ahmed H

    2012-10-16

    achievable with short intense pulses containing a large number of electrons, however, are limited to tens of nanometers and nanoseconds, respectively. This is because Coulomb repulsion is significant in such a pulse, and the electrons spread in space and time, thus limiting the beam coherence. It is therefore not possible to image the ultrafast elementary dynamics of complex transformations. The challenge was to retain the high spatial resolution of a conventional TEM while simultaneously enabling the temporal resolution required to visualize atomic-scale motions. In this Account, we discuss the development of four-dimensional ultrafast electron microscopy (4D UEM) and summarize techniques and applications that illustrate the power of the approach. In UEM, images are obtained either stroboscopically with coherent single-electron packets or with a single electron bunch. Coulomb repulsion is absent under the single-electron condition, thus permitting imaging, diffraction, and spectroscopy, all with high spatiotemporal resolution, the atomic scale (sub-nanometer and femtosecond). The time resolution is limited only by the laser pulse duration and energy carried by the electron packets; the CCD camera has no bearing on the temporal resolution. In the regime of single pulses of electrons, the temporal resolution of picoseconds can be attained when hundreds of electrons are in the bunch. The applications given here are selected to highlight phenomena of different length and time scales, from atomic motions during structural dynamics to phase transitions and nanomechanical oscillations. We conclude with a brief discussion of emerging methods, which include scanning ultrafast electron microscopy (S-UEM), scanning transmission ultrafast electron microscopy (ST-UEM) with convergent beams, and time-resolved imaging of biological structures at ambient conditions with environmental cells.

  6. Dosimetric Correction for a 4D-Computed Tomography Dataset using the Free-Form Deformation Algorithm

    NASA Astrophysics Data System (ADS)

    Markel, Daniel; Alasti, Hamideh; Chow, James C. L.

    2012-10-01

    A Free-Form Deformable (FFD) image registration algorithm in conjunction with 4D Computed Tomography (CT) images was implemented within a graphical user interface, FFD4D, for dosimetric calculations. The algorithm was developed using the cubic-B-spline method with smoothness corrections and registration point assistance to mark fudicials. Validation of the algorithm was performed with manually measured geometric differences using a QUASAR Respiratory Motion Phantom. In this work, we used the FFD algorithm to demonstrate dosimetric corrections amongst 10 breathing phases of a lung cancer patient using the 4D-CT image datasets. Different methods to enhance the image processing speed for high-performance computing were also discussed.

  7. Chondroblastoma of the thoracic vertebra.

    PubMed

    Attar, A; Ugur, H C; Caglar, Y S; Erdogan, A; Ozdemir, N

    2001-01-01

    A 48-year-old patient with interscapular pain was admitted to our clinic. MRI revealed a mass infiltrating the second thoracic vertebra and adjacent structures. No other clinical manifestations were observed in general examination. The patient underwent surgery and subtotal removal was achieved while anterior and posterior stabilisations were performed. Diagnosis was pathologically confirmed. As thoracic chondroblastoma cases are not frequent, we decided to present this case. PMID:11148083

  8. Motion4D-library extended

    NASA Astrophysics Data System (ADS)

    Müller, Thomas

    2011-06-01

    The new version of the Motion4D-library now also includes the integration of a Sachs basis and the Jacobi equation to determine gravitational lensing of pointlike sources for arbitrary spacetimes.New version program summaryProgram title: Motion4D-libraryCatalogue identifier: AEEX_v3_0Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AEEX_v3_0.htmlProgram obtainable from: CPC Program Library, Queen's University, Belfast, N. IrelandLicensing provisions: Standard CPC licence, http://cpc.cs.qub.ac.uk/licence/licence.htmlNo. of lines in distributed program, including test data, etc.: 219 441No. of bytes in distributed program, including test data, etc.: 6 968 223Distribution format: tar.gzProgramming language: C++Computer: All platforms with a C++ compilerOperating system: Linux, WindowsRAM: 61 MbytesClassification: 1.5External routines: Gnu Scientic Library (GSL) (http://www.gnu.org/software/gsl/)Catalogue identifier of previous version: AEEX_v2_0Journal reference of previous version: Comput. Phys. Comm. 181 (2010) 703Does the new version supersede the previous version?: YesNature of problem: Solve geodesic equation, parallel and Fermi-Walker transport in four-dimensional Lorentzian spacetimes. Determine gravitational lensing by integration of Jacobi equation and parallel transport of Sachs basis.Solution method: Integration of ordinary differential equations.Reasons for new version: The main novelty of the current version is the extension to integrate the Jacobi equation and the parallel transport of the Sachs basis along null geodesics. In combination, the change of the cross section of a light bundle and thus the gravitational lensing effect of a spacetime can be determined. Furthermore, we have implemented several new metrics.Summary of revisions: The main novelty of the current version is the integration of the Jacobi equation and the parallel transport of the Sachs basis along null geodesics. The corresponding set of equations readd2xμdλ2=-Γρ

  9. A proposed framework for consensus-based lung tumour volume auto-segmentation in 4D computed tomography imaging

    NASA Astrophysics Data System (ADS)

    Martin, Spencer; Brophy, Mark; Palma, David; Louie, Alexander V.; Yu, Edward; Yaremko, Brian; Ahmad, Belal; Barron, John L.; Beauchemin, Steven S.; Rodrigues, George; Gaede, Stewart

    2015-02-01

    This work aims to propose and validate a framework for tumour volume auto-segmentation based on ground-truth estimates derived from multi-physician input contours to expedite 4D-CT based lung tumour volume delineation. 4D-CT datasets of ten non-small cell lung cancer (NSCLC) patients were manually segmented by 6 physicians. Multi-expert ground truth (GT) estimates were constructed using the STAPLE algorithm for the gross tumour volume (GTV) on all respiratory phases. Next, using a deformable model-based method, multi-expert GT on each individual phase of the 4D-CT dataset was propagated to all other phases providing auto-segmented GTVs and motion encompassing internal gross target volumes (IGTVs) based on GT estimates (STAPLE) from each respiratory phase of the 4D-CT dataset. Accuracy assessment of auto-segmentation employed graph cuts for 3D-shape reconstruction and point-set registration-based analysis yielding volumetric and distance-based measures. STAPLE-based auto-segmented GTV accuracy ranged from (81.51  ±  1.92) to (97.27  ±  0.28)% volumetric overlap of the estimated ground truth. IGTV auto-segmentation showed significantly improved accuracies with reduced variance for all patients ranging from 90.87 to 98.57% volumetric overlap of the ground truth volume. Additional metrics supported these observations with statistical significance. Accuracy of auto-segmentation was shown to be largely independent of selection of the initial propagation phase. IGTV construction based on auto-segmented GTVs within the 4D-CT dataset provided accurate and reliable target volumes compared to manual segmentation-based GT estimates. While inter-/intra-observer effects were largely mitigated, the proposed segmentation workflow is more complex than that of current clinical practice and requires further development.

  10. A study on quantitative analysis of field size and dose by using gating system in 4D conformal radiation treatment

    NASA Astrophysics Data System (ADS)

    Ji, Youn-Sang; Dong, Kyung-Rae; Kim, Chang-Bok; Chung, Woon-Kwan; Cho, Jae-Hwan; Lee, Hae-Kag

    2012-10-01

    This study evaluated the gating-based 4-D conformal radiation therapy (4D-CT) treatment planning by a comparison with the common 3-D conformal radiation therapy (3D-CT) treatment planning and examined the change in treatment field size and dose to the tumors and adjacent normal tissues because an unnecessary dose is also included in the 3-D treatment planning for the radiation treatment of tumors in the chest and abdomen. The 3D-CT and gating-based 4D-CT images were obtained from patients who had undergone radiation treatment for chest and abdomen tumors in the oncology department. After establishing a treatment plan, the CT treatment and planning system were used to measure the change in field size for analysis. A dose volume histogram (DVH) was used to calculate the appropriate dose to planning target volume (PTV) tumors and adjacent normal tissue. The difference in the treatment volume of the chest was 0.6 and 0.83 cm on the X- and Y-axis, respectively, for the gross tumor volume (GTV). Accordingly, the values in the 4D-CT treatment planning were smaller and the dose was more concentrated by 2.7% and 0.9% on the GTV and clinical target volume (CTV), respectively. The normal tissues in the surrounding normal tissues were reduced by 3.0%, 7.2%, 0.4%, 1.7%, 2.6% and 0.2% in the bronchus, chest wall, esophagus, heart, lung and spinal cord, respectively. The difference in the treatment volume of the abdomen was 0.72 cm on the X-axis and 0.51 cm on the Y-axis for the GTV; and 1.06 cm on the X-axis and 1.85 cm on the Y-axis for the PTV. Therefore, the values in the 4D-CT treatment planning were smaller. The dose was concentrated by 6.8% and 4.3% on the GTV and PTV, respectively, whereas the adjacent normal tissues in the cord, Lt. kidney, Rt. kidney, small bowels and whole liver were reduced by 3.2%, 4.2%, 1.5%, 6.2% and 12.7%, respectively. The treatment field size was smaller in volume in the case of the 4D-CT treatment planning. In the DVH, the 4D-CT treatment

  11. Thoracic aortic dissection in a 38-year-old man.

    PubMed

    Tilney, Peter

    2010-01-01

    A few days before Christmas, a flight team was activated for an interfacility transfer of a 38-year-old man with a history of hypertension and spinal stenosis diagnosed with a thoracic aortic dissection. The patient was presented to a local community hospital complaining of nearly 5 days of left-sided rib pain. This afternoon when he stood up from a chair, he experienced a near-syncopal episode. Concurrently, he had an abrupt onset of a tearing sensation in his chest that radiated to thoracic spine in the region between his shoulder blades. Ground emergency medical services (EMS) was called, and the patient was transported to the community hospital. During the initial transport and evaluation by the emergency department (ED) staff, the patient was noted to be hypertensive, with a systolic blood pressure greater than 180 mmHg. In the ED, the patient received aspirin, morphine, and Lopressor. He underwent a chest x-ray (Figure 1) and computed tomography (CT) scan and was diagnosed with a type B thoracic aorta dissection, which was noted to start on the descending thoracic aorta distal to the left subclavian artery and extend to the level of the celiac trunk (Figure 2). Despite the initial beta blockade, the patient was noted to be profoundly hypertensive, with initial blood pressure greater than 190 mmHg systolic. The flight team was activated for hemodynamic management and rapid transport to a facility capable of vascular and cardiothoracic surgery.

  12. [Thoracic outlet syndrome].

    PubMed

    Sonoo, Masahiro

    2014-12-01

    Thoracic outlet syndrome (TOS) is a well-known disorder, but its definition has been disputed. TOS is differentiated into five distinct disorders: arterial vascular, venous vascular, traumatic neurovascular, true neurologic (TN-TOS), and nonspecific TOS. TN-TOS is caused by compression of the lower plexus (T1>C8 roots and/or lower trunk) by a fibrous band. The most frequent presenting symptoms are insidious-onset atrophy and weakness of the intrinsic hand muscles, predominantly in the thenar eminence and radial digital flexors. Numbness and sensory loss are usually present, mainly in the ulnar forearm, although severe pain or pain/paresthesia proximal to the elbow can occur; however, sensory symptoms or signs can be absent in some patients. Nerve conduction studies are pathognomonic and show the loss or severe attenuation of the sensory nerve action potential (SNAP) of the medial antebrachial cutaneous nerve. Additionally, they show a severely depressed median compound muscle action potential (CMAP) and, subsequently, a depressed ulnar CMAP and SNAP. TN-TOS is a rare disorder, although its incidence may be higher than previously believed. Hirayama disease is an important differential diagnosis. Nonspecific TOS, which is mainly diagnosed by provocative maneuvers, corresponds to the classical concept of TOS. However, this concept is now challenged and the existence of nonspecific TOS is doubted. PMID:25475030

  13. The 4D-TECS integration for NASA TSRV airplane

    NASA Technical Reports Server (NTRS)

    Kaminer, I.; Oshaughnessy, P. R.

    1989-01-01

    The integration of the Total Energy Control System (TECS) concept with 4D navigation is described. This integration was made to increase the operational capacity of modern aircraft and encourage incorporation of this increased capability with the evolving National Airspace System (NAS). Described herein is: 4D smoothing, the basic concepts of TECS, the spoiler integration concept, an algorithm for nulling out time error, speed and altitude profile modes, manual spoiler implementation, 4D logic, and the results of linear and nonlinear analysis.

  14. Killing Weeds with 2,4-D. Extension Bulletin 389.

    ERIC Educational Resources Information Center

    Lee, Oliver C.

    Discussed is the use of the herbicide 2,4-D. Though written for farmers and agricultural workers, the pamphlet considers turf weed control and use of 2,4-D near ornamental plants. Aspects of the use of this herbicide covered are: (1) the common forms of 2,4-D; (2) plant responses and tolerances to the herbicide; (3) dilution and concentration of…

  15. Computed tomography of thoracic and lumbar spine fractures that have been treated with Harrington instrumentation

    SciTech Connect

    Golimbu, C.; Firooznia, H.; Rafii, M.; Engler, G.; Delman, A.

    1984-06-01

    Twenty patients with fractures of the thoracic and lumbar spine underwent computed tomography (CT) following Harrington distraction instrumentation and a spinal fusion. CT was done to search for a cause of persistent cord or nerve root compression in those patients who failed to improve and completely recover their partial neurologic deficit (14 cases). The most common abnormality was the presence of residual bone fragments originating in the burst fracture of a vertebral body displaced posteriorly, into the spinal canal. In patients with complications in the late recovery period, CT found exuberant callus indenting the canal or lack of fusion of the bone grafts placed in the anterolateral aspect of the vertebral bodies. This experience indicates that CT is the modality of choice for spinal canal evaluation in those patients who fail to have an optimal clinical course following fractures of the thoracic and lumbar spine treated with Harrington rods.

  16. Pros and cons for C4d as a biomarker.

    PubMed

    Cohen, Danielle; Colvin, Robert B; Daha, Mohamed R; Drachenberg, Cinthia B; Haas, Mark; Nickeleit, Volker; Salmon, Jane E; Sis, Banu; Zhao, Ming-Hui; Bruijn, Jan A; Bajema, Ingeborg M

    2012-04-01

    The introduction of C4d in daily clinical practice in the late nineties aroused an ever-increasing interest in the role of antibody-mediated mechanisms in allograft rejection. As a marker of classical complement activation, C4d made it possible to visualize the direct link between anti-donor antibodies and tissue injury at sites of antibody binding in a graft. With the expanding use of C4d worldwide several limitations of C4d were identified. For instance, in ABO-incompatible transplantations C4d is present in the majority of grafts but this seems to point at 'graft accommodation' rather than antibody-mediated rejection. C4d is now increasingly recognized as a potential biomarker in other fields where antibodies can cause tissue damage, such as systemic autoimmune diseases and pregnancy. In all these fields, C4d holds promise to detect patients at risk for the consequences of antibody-mediated disease. Moreover, the emergence of new therapeutics that block complement activation makes C4d a marker with potential to identify patients who may possibly benefit from these drugs. This review provides an overview of the past, present, and future perspectives of C4d as a biomarker, focusing on its use in solid organ transplantation and discussing its possible new roles in autoimmunity and pregnancy. PMID:22297669

  17. VMAT QA: Measurement-guided 4D dose reconstruction on a patient

    SciTech Connect

    Nelms, Benjamin E.; Opp, Daniel; Robinson, Joshua; Wolf, Theresa K.; Zhang, Geoffrey; Moros, Eduardo; Feygelman, Vladimir

    2012-07-15

    global fluence change. Results: Across four TG-119 plans, the average PTV point dose difference in the cube between 3DVH and ion chamber is 0.1 {+-} 1.0%. Average film vs TPS {gamma}-analysis passing rates are 83.0%, 91.1%, and 98.4% for 1%/2 mm, 2%/2 mm, and 3%/3 mm threshold combinations, respectively, while average film vs 3DVH {gamma}-analysis passing rates are 88.6%, 96.1%, and 99.5% for the same respective criteria. 4D MGDR was also sufficiently accurate. First, for 99.5% voxels in each case, the doses from 3D and 4D MGDR at the end of delivery agree within 0.5%local dose-error/1 mm distance. Moreover, all failing voxels are confined to the edge of the cylindrical reconstruction volume. Second, dose vs time curves track between the ion chamber and 4D MGDR within 1%. Finally, 4D MGDR dose changes linearly with the accelerator output: the difference between cumulative ion chamber and MGDR dose changed by no more than 1% (randomly) with the output variation range of 10%. Conclusions: Even for a well-commissioned TPS, comparison metrics show better agreement on average to MGDR than to TPS on the arbitrary-shaped measurable 'patient.' The method requires no more accelerator time than standard QA, while producing more clinically relevant information. Validation in a heterogeneous thoracic phantom is under way, as is the ultimate application of 4D MGDR to virtual motion studies.

  18. Inverse planning for four-dimensional (4D) volumetric modulated arc therapy

    SciTech Connect

    Ma Yunzhi; Chang, Daniel; Keall, Paul; Xie Yiaoqin; Park, Jae-yoon; Suh, Tae-Suk; Xing Lei

    2010-11-15

    Purpose: To develop a 4D volumetric modulated arc therapy (VMAT) inverse planning framework. Methods: 4D VMAT inverse planning aims to derive an aperture and weight modulated arc therapy treatment plan that optimizes the accumulated dose distribution from all gantry angles and breathing phases. Under an assumption that the gantry rotation and patient breathing are synchronized (i.e., there is a functional relationship between the phase of the patient breathing cycle and the beam angle), the authors compute the contribution from different respiration phases through the registration of the phased CT images. The accumulative dose distribution is optimized by iteratively adjusting the aperture shape and weight of each beam through the minimization of the planning objective function. For comparison, traditional 3D VMAT plans are also performed for the two cases and the performance of the proposed technique is demonstrated. Results: A framework for 4D VMAT inverse planning has been proposed. With the consideration of the extra dimension of time in VMAT, a tighter target margin can be achieved with a full duty cycle, which is otherwise not achievable simultaneously by either 3D VMAT optimization or gated VMAT. Conclusions: The 4D VMAT planning formulism proposed here provides useful insight on how the ''time'' dimension can be exploited in rotational arc therapy to maximally compensate for the intrafraction organ motion.

  19. Experimental investigation of irregular motion impact on 4D PET-based particle therapy monitoring.

    PubMed

    Tian, Y; Stützer, K; Enghardt, W; Priegnitz, M; Helmbrecht, S; Bert, C; Fiedler, F

    2016-01-21

    Particle therapy positron emission tomography (PT-PET) is an in vivo and non-invasive imaging technique to monitor treatment delivery in particle therapy. The inevitable patient respiratory motion during irradiation causes artefacts and inaccurate activity distribution in PET images. Four-dimensional (4D) maximum likelihood expectation maximisation (4D MLEM) allows for a compensation of these effects, but has up to now been restricted to regular motion for PT-PET investigations. However, intra-fractional motion during treatment might differ from that during acquisition of the 4D-planning CT (e.g. amplitude variation, baseline drift) and therefore might induce inaccurate 4D PET reconstruction results. This study investigates the impact of different irregular analytical one-dimensional (1D) motion patterns on PT-PET imaging by means of experiments with a radioactive source and irradiated moving phantoms. Three sorting methods, namely phase sorting, equal amplitude sorting and event-based amplitude sorting, were applied to manage the PET list-mode data. The influence of these sorting methods on the motion compensating algorithm has been analysed. The event-based amplitude sorting showed a superior performance and it is applicable for irregular motions with ⩽ 4 mm amplitude elongation and drift. For motion with 10 mm baseline drift, the normalised root mean square error was as high as 10.5% and a 10 mm range deviation was observed.

  20. Experimental investigation of irregular motion impact on 4D PET-based particle therapy monitoring

    NASA Astrophysics Data System (ADS)

    Tian, Y.; Stützer, K.; Enghardt, W.; Priegnitz, M.; Helmbrecht, S.; Bert, C.; Fiedler, F.

    2016-01-01

    Particle therapy positron emission tomography (PT-PET) is an in vivo and non-invasive imaging technique to monitor treatment delivery in particle therapy. The inevitable patient respiratory motion during irradiation causes artefacts and inaccurate activity distribution in PET images. Four-dimensional (4D) maximum likelihood expectation maximisation (4D MLEM) allows for a compensation of these effects, but has up to now been restricted to regular motion for PT-PET investigations. However, intra-fractional motion during treatment might differ from that during acquisition of the 4D-planning CT (e.g. amplitude variation, baseline drift) and therefore might induce inaccurate 4D PET reconstruction results. This study investigates the impact of different irregular analytical one-dimensional (1D) motion patterns on PT-PET imaging by means of experiments with a radioactive source and irradiated moving phantoms. Three sorting methods, namely phase sorting, equal amplitude sorting and event-based amplitude sorting, were applied to manage the PET list-mode data. The influence of these sorting methods on the motion compensating algorithm has been analysed. The event-based amplitude sorting showed a superior performance and it is applicable for irregular motions with  ⩽4 mm amplitude elongation and drift. For motion with 10 mm baseline drift, the normalised root mean square error was as high as 10.5% and a 10 mm range deviation was observed.

  1. Experimental investigation of irregular motion impact on 4D PET-based particle therapy monitoring.

    PubMed

    Tian, Y; Stützer, K; Enghardt, W; Priegnitz, M; Helmbrecht, S; Bert, C; Fiedler, F

    2016-01-21

    Particle therapy positron emission tomography (PT-PET) is an in vivo and non-invasive imaging technique to monitor treatment delivery in particle therapy. The inevitable patient respiratory motion during irradiation causes artefacts and inaccurate activity distribution in PET images. Four-dimensional (4D) maximum likelihood expectation maximisation (4D MLEM) allows for a compensation of these effects, but has up to now been restricted to regular motion for PT-PET investigations. However, intra-fractional motion during treatment might differ from that during acquisition of the 4D-planning CT (e.g. amplitude variation, baseline drift) and therefore might induce inaccurate 4D PET reconstruction results. This study investigates the impact of different irregular analytical one-dimensional (1D) motion patterns on PT-PET imaging by means of experiments with a radioactive source and irradiated moving phantoms. Three sorting methods, namely phase sorting, equal amplitude sorting and event-based amplitude sorting, were applied to manage the PET list-mode data. The influence of these sorting methods on the motion compensating algorithm has been analysed. The event-based amplitude sorting showed a superior performance and it is applicable for irregular motions with ⩽ 4 mm amplitude elongation and drift. For motion with 10 mm baseline drift, the normalised root mean square error was as high as 10.5% and a 10 mm range deviation was observed. PMID:26733104

  2. Automated 4D lung computed tomography reconstruction during free breathing for conformal radiation therapy

    NASA Astrophysics Data System (ADS)

    El Naqa, Issam M.; Low, Daniel A.; Christensen, Gary E.; Parikh, Parag J.; Song, Joo Hyun; Nystrom, Michelle M.; Lu, Wei; Deasy, Joseph O.; Hubenschmidt, James P.; Wahab, Sasha H.; Mutic, Sasa; Singh, Anurag K.; Bradley, Jeffrey D.

    2004-04-01

    We are developing 4D-CT to provide breathing motion information (trajectories) for radiation therapy treatment planning of lung cancer. Potential applications include optimization of intensity-modulated beams in the presence of breathing motion and intra-fraction target volume margin determination for conformal therapy. The images are acquired using a multi-slice CT scanner while the patient undergoes simultaneous quantitative spirometry. At each couch position, the CT scanner is operated in ciné mode and acquires up to 15 scans of 12 slices each. Each CT scan is associated with the measured tidal volume for retrospective reconstruction of 3D CT scans at arbitrary tidal volumes. The specific tasks of this project involves the development of automated registration of internal organ motion (trajectories) during breathing. A modified least-squares based optical flow algorithm tracks specific features of interest by modifying the eigenvalues of gradient matrix (gradient structural tensor). Good correlations between the measured motion and spirometry-based tidal volume are observed and evidence of internal hysteresis is also detected.

  3. Bone scaffolds loaded with siRNA-Semaphorin4d for the treatment of osteoporosis related bone defects

    PubMed Central

    Zhang, Yufeng; Wei, Lingfei; Miron, Richard J.; Shi, Bin; Bian, Zhuan

    2016-01-01

    Osteoporosis is a prominent disorder affecting over 200 million people worldwide. Recently, semaphorins have been implicated in the cell-cell communication between osteoclasts and osteoblasts and have been associated with the progression of osteoporosis. Previously, we demonstrated that knockdown of semaphorin4d (Sema4d) using siRNA delivered with a bone-targeting system prevented bone loss in an osteoporotic animal model. Here, we used this bone-specific technology containing siRNA-Sema4d and fabricated a PLLA scaffold capable of enhancing bone repair following fracture. We investigated the ability of the implant to release siRNA-Sema4d into the surrounding tissues over time and to influence new bone formation in a 3 mm femur osteoporotic defect model in ovariectomized rats. Delivery of the bone-targeting system released from PLLA scaffolds began 2 hours post-implantation, peaked at 1 day, and was sustained over a 21 day period. μCT analysis demonstrated a significantly higher bone volume/total volume bone mineral density and number of osteoblasts in the rats that were transplanted with scaffolds loaded with siRNA-Sema4d. These results confirm the specific role of Sema4d in bone remodeling and demonstrate that significant increases in the speed and quality of new bone formation occur when siRNA-Sema4d is delivered via a PLLA scaffold. PMID:27254469

  4. A method for deriving a 4D-interpolated balanced planning target for mobile tumor radiotherapy

    SciTech Connect

    Roland, Teboh; Hales, Russell; McNutt, Todd; Wong, John; Simari, Patricio; Tryggestad, Erik

    2012-01-15

    Purpose: Tumor control and normal tissue toxicity are strongly correlated to the tumor and normal tissue volumes receiving high prescribed dose levels in the course of radiotherapy. Planning target definition is, therefore, crucial to ensure favorable clinical outcomes. This is especially important for stereotactic body radiation therapy of lung cancers, characterized by high fractional doses and steep dose gradients. The shift in recent years from population-based to patient-specific treatment margins, as facilitated by the emergence of 4D medical imaging capabilities, is a major improvement. The commonly used motion-encompassing, or internal-target volume (ITV), target definition approach provides a high likelihood of coverage for the mobile tumor but inevitably exposes healthy tissue to high prescribed dose levels. The goal of this work was to generate an interpolated balanced planning target that takes into account both tumor coverage and normal tissue sparing from high prescribed dose levels, thereby improving on the ITV approach. Methods: For each 4DCT dataset, 4D deformable image registration was used to derive two bounding targets, namely, a 4D-intersection and a 4D-composite target which minimized normal tissue exposure to high prescribed dose levels and maximized tumor coverage, respectively. Through definition of an ''effective overlap volume histogram'' the authors derived an ''interpolated balanced planning target'' intended to balance normal tissue sparing from prescribed doses with tumor coverage. To demonstrate the dosimetric efficacy of the interpolated balanced planning target, the authors performed 4D treatment planning based on deformable image registration of 4D-CT data for five previously treated lung cancer patients. Two 4D plans were generated per patient, one based on the interpolated balanced planning target and the other based on the conventional ITV target. Plans were compared for tumor coverage and the degree of normal tissue sparing

  5. Phosphodiesterase 4D Inhibitors Limit Prostate Cancer Growth Potential

    PubMed Central

    Powers, Ginny L.; Hammer, Kimberly D.P.; Domenech, Maribella; Frantskevich, Katsiaryna; Malinowski, Rita L.; Bushman, Wade; Beebe, David J.; Marker, Paul C.

    2014-01-01

    Phosphodiesterase 4D (PDE4D) has recently been implicated as a proliferation-promoting factor in prostate cancer and is over-expressed in human prostate carcinoma. However, the effects of PDE4D inhibition using pharmacological inhibitors have not been examined in prostate cancer. These studies examined the effects of selective PDE4D inhibitors, NVP-ABE171 and cilomilast, as anti-prostate cancer therapies in both in vitro and in vivo models. The effects of PDE4D inhibitors on pathways that are critical in prostate cancer and/or downstream of cyclic AMP (cAMP) were examined. Both NVP-ABE171 and cilomilast decreased cell growth. In vitro, PDE4D inhibitors lead to decreased signaling of the sonic hedgehog (SHH), Androgen Receptor (AR), and MAPK pathways, but growth inhibition was best correlated to the sonic hedgehog pathway. PDE4D inhibition also reduced proliferation of epithelial cells induced by paracrine signaling from co-cultured stromal cells that had activated hedgehog signaling. In addition, PDE4D inhibitors decreased the weight of the prostate in wild-type mice. Prostate cancer xenografts grown in nude mice that were treated with cilomilast or NVP-ABE171 had decreased wet weight and increased apoptosis compared to vehicle treated controls. These studies suggest the pharmacological inhibition of PDE4D using small molecule inhibitors is an effective option for prostate cancer therapy. Implications PDE4D inhibitors decrease the growth of prostate cancer cells in vivo and in vitro, and PDE4D inhibition has therapeutic potential in prostate cancer. PMID:25149359

  6. [A Dumbbell-Type Thoracic Spinal Lipoma: A Case Report].

    PubMed

    Takamiya, Soichiro; Hida, Kazutoshi; Yano, Shunsuke; Sasamori, Toru; Seki, Toshitaka; Saito, Hisatoshi

    2016-06-01

    Spinal lipomas are rare, accounting for less than 1% of all spinal tumors. Most are associated with spinal dysraphism. Spinal lipomas without spinal dysraphism are uncommon;they are typically subpial tumors. Some tumors are located both inside and outside the dura mater (so-called "dumbbell-type"). Herein, we report a patient with a dumbbell-type thoracic spinal lipoma. A man in his 50's complained of progressive gait disturbance, dysesthesia in his left leg, and hyperesthesia in his right leg. His symptoms were worsened by exercise. CT and MRI revealed a thoracic spinal lipoma extending from the spinal cord to the intervertebral foramen at the Th 6-8 level. He underwent partial tumor removal and untethering. Postoperatively he reported gradual symptom abatement. Dumbbell-type spinal lipomas are very rare. Besides partial removal of the tumor, untethering should be considered when symptoms are associated with tethering of the spinal cord. PMID:27270148

  7. 4D Printing with Mechanically Robust, Thermally Actuating Hydrogels.

    PubMed

    Bakarich, Shannon E; Gorkin, Robert; in het Panhuis, Marc; Spinks, Geoffrey M

    2015-06-01

    A smart valve is created by 4D printing of hydrogels that are both mechanically robust and thermally actuating. The printed hydrogels are made up of an interpenetrating network of alginate and poly(N-isopropylacrylamide). 4D structures are created by printing the "dynamic" hydrogel ink alongside other static materials. PMID:25864515

  8. 32 CFR 1645.4 - Exclusion from Class 4-D.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... MINISTERS OF RELIGION § 1645.4 Exclusion from Class 4-D. A registrant is excluded from Class 4-D when his... duly ordained minister of religion in accordance with the ceremonial rite or discipline of a church... principles of religion and administer the ordinances of public worship, as embodied in the creed...

  9. 4D Printing with Mechanically Robust, Thermally Actuating Hydrogels.

    PubMed

    Bakarich, Shannon E; Gorkin, Robert; in het Panhuis, Marc; Spinks, Geoffrey M

    2015-06-01

    A smart valve is created by 4D printing of hydrogels that are both mechanically robust and thermally actuating. The printed hydrogels are made up of an interpenetrating network of alginate and poly(N-isopropylacrylamide). 4D structures are created by printing the "dynamic" hydrogel ink alongside other static materials.

  10. 32 CFR 1645.4 - Exclusion from Class 4-D.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... MINISTERS OF RELIGION § 1645.4 Exclusion from Class 4-D. A registrant is excluded from Class 4-D when his... duly ordained minister of religion in accordance with the ceremonial rite or discipline of a church... principles of religion and administer the ordinances of public worship, as embodied in the creed...

  11. 32 CFR 1645.4 - Exclusion from Class 4-D.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... MINISTERS OF RELIGION § 1645.4 Exclusion from Class 4-D. A registrant is excluded from Class 4-D when his... duly ordained minister of religion in accordance with the ceremonial rite or discipline of a church... principles of religion and administer the ordinances of public worship, as embodied in the creed...

  12. 32 CFR 1645.4 - Exclusion from Class 4-D.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... MINISTERS OF RELIGION § 1645.4 Exclusion from Class 4-D. A registrant is excluded from Class 4-D when his... duly ordained minister of religion in accordance with the ceremonial rite or discipline of a church... principles of religion and administer the ordinances of public worship, as embodied in the creed...

  13. 32 CFR 1645.4 - Exclusion from Class 4-D.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... MINISTERS OF RELIGION § 1645.4 Exclusion from Class 4-D. A registrant is excluded from Class 4-D when his... duly ordained minister of religion in accordance with the ceremonial rite or discipline of a church... principles of religion and administer the ordinances of public worship, as embodied in the creed...

  14. Development of the 4D Phantom for patient-specific, end-to-end radiation therapy QA

    NASA Astrophysics Data System (ADS)

    Malinowski, K.; Noel, C.; Lu, W.; Lechleiter, K.; Hubenschmidt, J.; Low, D.; Parikh, P.

    2007-03-01

    In many patients respiratory motion causes motion artifacts in CT images, thereby inhibiting precise treatment planning and lowering the ability to target radiation to tumors. The 4D Phantom, which includes a 3D stage and a 1D stage that each are capable of arbitrary motion and timing, was developed to serve as an end-to-end radiation therapy QA device that could be used throughout CT imaging, radiation therapy treatment planning, and radiation therapy delivery. The dynamic accuracy of the system was measured with a camera system. The positional error was found to be equally likely to occur in the positive and negative directions for each axis, and the stage was within 0.1 mm of the desired position 85% of the time. In an experiment designed to use the 4D Phantom's encoders to measure trial-to-trial precision of the system, the 4D Phantom reproduced the motion during variable bag ventilation of a transponder that had been bronchoscopically implanted in a canine lung. In this case, the encoder readout indicated that the stage was within 10 microns of the sent position 94% of the time and that the RMS error was 7 microns. Motion artifacts were clearly visible in 3D and respiratory-correlated (4D) CT scans of phantoms reproducing tissue motion. In 4D CT scans, apparent volume was found to be directly correlated to instantaneous velocity. The system is capable of reproducing individual patient-specific tissue trajectories with a high degree of accuracy and precision and will be useful for end-to-end radiation therapy QA.

  15. SU-D-17A-04: The Impact of Audiovisual Biofeedback On Image Quality During 4D Functional and Anatomic Imaging: Results of a Prospective Clinical Trial

    SciTech Connect

    Keall, P; Pollock, S; Yang, J; Diehn, M; Berger, J; Graves, E; Loo, B; Yamamoto, T

    2014-06-01

    Purpose: The ability of audiovisual (AV) biofeedback to improve breathing regularity has not previously been investigated for functional imaging studies. The purpose of this study was to investigate the impact of AV biofeedback on 4D-PET and 4D-CT image quality in a prospective clinical trial. We hypothesized that motion blurring in 4D-PET images and the number of artifacts in 4D-CT images are reduced using AV biofeedback. Methods: AV biofeedback is a real-time, interactive and personalized system designed to help a patient self-regulate his/her breathing using a patient-specific representative waveform and musical guides. In an IRB-approved prospective clinical trial, 4D-PET and 4D-CT images of 10 lung cancer patients were acquired with AV biofeedback (AV) and free breathing (FB). The 4D-PET images in 6 respiratory bins were analyzed for motion blurring by: (1) decrease of GTVPET and (2) increase of SUVmax in 4-DPET compared to 3D-PET. The 4D-CT images were analyzed for artifacts by: (1) comparing normalized cross correlation-based scores (NCCS); and (2) quantifying a visual assessment score (VAS). A two-tailed paired t-test was used to test the hypotheses. Results: The impact of AV biofeedback on 4D-PET and 4D-CT images varied widely between patients, suggesting inconsistent patient comprehension and capability. Overall, the 4D-PET decrease of GTVPET was 2.0±3.0cm3 with AV and 2.3±3.9cm{sup 3} for FB (p=0.61). The 4D-PET increase of SUVmax was 1.6±1.0 with AV and 1.1±0.8 with FB (p=0.002). The 4D-CT NCCS were 0.65±0.27 with AV and 0.60±0.32 for FB (p=0.32). The 4D-CT VAS was 0.0±2.7 (p=ns). Conclusion: A 10-patient study demonstrated a statistically significant reduction of motion blurring of AV over FB for 1/2 functional 4D-PET imaging metrics. No difference between AV and FB was found for 2 anatomic 4D-CT imaging metrics. Future studies will focus on optimizing the human-computer interface and including patient training sessions for improved

  16. Four-dimensional (4D) Motion Detection to Correct Respiratory Effects in Treatment Response Assessment Using Molecular Imaging Biomarkers

    PubMed Central

    Schreibmann, Eduard; Crocker, Ian; Schuster, David M.; Curran, Walter J.; Fox, Tim

    2014-01-01

    Observing early metabolic changes in positron emission tomography (PET) is an essential tool to assess treatment efficiency in radiotherapy. However, for thoracic regions, the use of three-dimensional (3D) PET imaging is unfeasible because the radiotracer activity is smeared by the respiratory motion and averaged during the imaging acquisition process. This motion-induced degradation is similar in magnitude with the treatment-induced changes, and the two occurrences become indiscernible. We present a customized temporal-spatial deformable registration method for quantifying respiratory motion in a four-dimensional (4D) PET dataset. Once the motion is quantified, a motion-corrected (MC) dataset is created by tracking voxels to eliminate breathing-induced changes in the 4D imaging scan. The 4D voxel-tracking data is then summed to yield a 3D MC-PET scan containing only treatment-induced changes. This proof of concept is exemplified on both phantom and clinical data, where the proposed algorithm tracked the trajectories of individual points through the 4D datasets reducing motion to less than 4 mm in all phases. This correction approach using deformable registration can discern motion blurring from treatment-induced changes in treatment response assessment using PET imaging. PMID:24000982

  17. Thoracic Radiculopathy due to Rare Causes

    PubMed Central

    2016-01-01

    Thoracic radiculopathy represents an uncommon spinal disorder that is frequently overlooked in the evaluation of thoracic, or abdominal pain syndrome. The clinical representation of this uncommon disorder is often atypical. With many differential diagnoses to consider, it is not surprising that the cause of thoracic radiculopathy is often not discovered for months, or years, after the symptoms arise. We report two rare cases of thoracic radiculopathy; one case was caused by extraskeletal Ewing sarcoma (EES) along the thoracic paraspinal area, and the other by foraminal stenosis, due to a bony spur of the thoracic vertebra. As such, thoracic radiculopathy should be considered in the diagnosis of patients with thoracic and abdominal pain, especially if initial diagnostic studies are inconclusive. PMID:27446792

  18. 4D motion animation of coronary arteries from rotational angiography

    NASA Astrophysics Data System (ADS)

    Holub, Wolfgang; Rohkohl, Christopher; Schuldhaus, Dominik; Prümmer, Marcus; Lauritsch, Günter; Hornegger, Joachim

    2011-03-01

    Time-resolved 3-D imaging of the heart is a major research topic in the medical imaging community. Recent advances in the interventional cardiac 3-D imaging from rotational angiography (C-arm CT) are now also making 4-D imaging feasible during procedures in the catheter laboratory. State-of-the-art reconstruction algorithms try to estimate the cardiac motion and utilize the motion field to enhance the reconstruction of a stable cardiac phase (diastole). The available data offers a handful of opportunities during interventional procedures, e.g. the ECG-synchronized dynamic roadmapping or the computation and analysis of functional parameters. In this paper we will demonstrate that the motion vector field (MVF) that is output by motion compensated image reconstruction algorithms is in general not directly usable for animation and motion analysis. Dependent on the algorithm different defects are investigated. A primary issue is that the MVF needs to be inverted, i.e. the wrong direction of motion is provided. A second major issue is the non-periodicity of cardiac motion. In algorithms which compute a non-periodic motion field from a single rotation the in depth motion information along viewing direction is missing, since this cannot be measured in the projections. As a result, while the MVF improves reconstruction quality, it is insufficient for motion animation and analysis. We propose an algorithm to solve both problems, i.e. inversion and missing in-depth information in a unified framework. A periodic version of the MVF is approximated. The task is formulated as a linear optimization problem where a parametric smooth motion model based on B-splines is estimated from the MVF. It is shown that the problem can be solved using a sparse QR factorization within a clinical feasible time of less than one minute. In a phantom experiment using the publicly available CAVAREV platform, the average quality of a non-periodic animation could be increased by 39% by applying the

  19. Graph-based retrospective 4D image construction from free-breathing MRI slice acquisitions

    NASA Astrophysics Data System (ADS)

    Tong, Yubing; Udupa, Jayaram K.; Ciesielski, Krzysztof C.; McDonough, Joseph M.; Mong, Andrew; Campbell, Robert M.

    2014-03-01

    4D or dynamic imaging of the thorax has many potential applications [1, 2]. CT and MRI offer sufficient speed to acquire motion information via 4D imaging. However they have different constraints and requirements. For both modalities both prospective and retrospective respiratory gating and tracking techniques have been developed [3, 4]. For pediatric imaging, x-ray radiation becomes a primary concern and MRI remains as the de facto choice. The pediatric subjects we deal with often suffer from extreme malformations of their chest wall, diaphragm, and/or spine, as such patient cooperation needed by some of the gating and tracking techniques are difficult to realize without causing patient discomfort. Moreover, we are interested in the mechanical function of their thorax in its natural form in tidal breathing. Therefore free-breathing MRI acquisition is the ideal modality of imaging for these patients. In our set up, for each coronal (or sagittal) slice position, slice images are acquired at a rate of about 200-300 ms/slice over several natural breathing cycles. This produces typically several thousands of slices which contain both the anatomic and dynamic information. However, it is not trivial to form a consistent and well defined 4D volume from these data. In this paper, we present a novel graph-based combinatorial optimization solution for constructing the best possible 4D scene from such data entirely in the digital domain. Our proposed method is purely image-based and does not need breath holding or any external surrogates or instruments to record respiratory motion or tidal volume. Both adult and children patients' data are used to illustrate the performance of the proposed method. Experimental results show that the reconstructed 4D scenes are smooth and consistent spatially and temporally, agreeing with known shape and motion of the lungs.

  20. A set of 4D pediatric XCAT reference phantoms for multimodality research

    SciTech Connect

    Norris, Hannah Zhang, Yakun; Bond, Jason; Sturgeon, Gregory M.; Samei, E.; Segars, W. P.; Minhas, Anum; Frush, D.; Tward, Daniel J.; Ratnanather, J. T.; Miller, M. I.

    2014-03-15

    Purpose: The authors previously developed an adult population of 4D extended cardiac-torso (XCAT) phantoms for multimodality imaging research. In this work, the authors develop a reference set of 4D pediatric XCAT phantoms consisting of male and female anatomies at ages of newborn, 1, 5, 10, and 15 years. These models will serve as the foundation from which the authors will create a vast population of pediatric phantoms for optimizing pediatric CT imaging protocols. Methods: Each phantom was based on a unique set of CT data from a normal patient obtained from the Duke University database. The datasets were selected to best match the reference values for height and weight for the different ages and genders according to ICRP Publication 89. The major organs and structures were segmented from the CT data and used to create an initial pediatric model defined using nonuniform rational B-spline surfaces. The CT data covered the entire torso and part of the head. To complete the body, the authors manually added on the top of the head and the arms and legs using scaled versions of the XCAT adult models or additional models created from cadaver data. A multichannel large deformation diffeomorphic metric mapping algorithm was then used to calculate the transform from a template XCAT phantom (male or female 50th percentile adult) to the target pediatric model. The transform was applied to the template XCAT to fill in any unsegmented structures within the target phantom and to implement the 4D cardiac and respiratory models in the new anatomy. The masses of the organs in each phantom were matched to the reference values given in ICRP Publication 89. The new reference models were checked for anatomical accuracy via visual inspection. Results: The authors created a set of ten pediatric reference phantoms that have the same level of detail and functionality as the original XCAT phantom adults. Each consists of thousands of anatomical structures and includes parameterized models

  1. A set of 4D pediatric XCAT reference phantoms for multimodality research

    PubMed Central

    Norris, Hannah; Zhang, Yakun; Bond, Jason; Sturgeon, Gregory M.; Minhas, Anum; Tward, Daniel J.; Ratnanather, J. T.; Miller, M. I.; Frush, D.; Samei, E.; Segars, W. P.

    2014-01-01

    Purpose: The authors previously developed an adult population of 4D extended cardiac-torso (XCAT) phantoms for multimodality imaging research. In this work, the authors develop a reference set of 4D pediatric XCAT phantoms consisting of male and female anatomies at ages of newborn, 1, 5, 10, and 15 years. These models will serve as the foundation from which the authors will create a vast population of pediatric phantoms for optimizing pediatric CT imaging protocols. Methods: Each phantom was based on a unique set of CT data from a normal patient obtained from the Duke University database. The datasets were selected to best match the reference values for height and weight for the different ages and genders according to ICRP Publication 89. The major organs and structures were segmented from the CT data and used to create an initial pediatric model defined using nonuniform rational B-spline surfaces. The CT data covered the entire torso and part of the head. To complete the body, the authors manually added on the top of the head and the arms and legs using scaled versions of the XCAT adult models or additional models created from cadaver data. A multichannel large deformation diffeomorphic metric mapping algorithm was then used to calculate the transform from a template XCAT phantom (male or female 50th percentile adult) to the target pediatric model. The transform was applied to the template XCAT to fill in any unsegmented structures within the target phantom and to implement the 4D cardiac and respiratory models in the new anatomy. The masses of the organs in each phantom were matched to the reference values given in ICRP Publication 89. The new reference models were checked for anatomical accuracy via visual inspection. Results: The authors created a set of ten pediatric reference phantoms that have the same level of detail and functionality as the original XCAT phantom adults. Each consists of thousands of anatomical structures and includes parameterized models

  2. 4D-fingerprints, universal QSAR and QSPR descriptors.

    PubMed

    Senese, Craig L; Duca, J; Pan, D; Hopfinger, A J; Tseng, Y J

    2004-01-01

    An elusive goal in the field of chemoinformatics and molecular modeling has been the generation of a set of descriptors that, once calculated for a molecule, may be used in a wide variety of applications. Since such universal descriptors are generated free from external constraints, they are inherently independent of the data set in which they are employed. The realization of a set of universal descriptors would significantly streamline such chemoinformatics tasks as virtual high-throughout screening (VHTS) and toxicity profiling. The current study reports the derivation and validation of a potential set of universal descriptors, referred to as the 4D-fingerprints. The 4D-fingerprints are derived from the 4D-molecular similarity analysis. To evaluate the applicability of the 4D-fingerprints as universal descriptors, they are used to generate descriptive QSAR models for 5 independent training sets. Each of the training sets has been analyzed previously by several varying QSAR methods, and the results of the models generated using the 4D-fingerprints are compared to the results of the previous QSAR analyses. It was found that the models generated using the 4D-fingerprints are comparable in quality, based on statistical measures of fit and test set prediction, to the previously reported models for the other QSAR methods. This finding is particularly significant considering the 4D-fingerprints are generated independent of external constraints such as alignment, while the QSAR methods used for comparison all require an alignment analysis.

  3. Primary Intimal Sarcoma of Thoracic Aorta Presenting as Hypertensive Crisis

    PubMed Central

    Lin, Shu-I; Su, Min-I; Tsai, Cheng-Ting

    2015-01-01

    We report a 45-year-old woman who presented to our facility in a hypertensive crisis. Computed tomography (CT) revealed a thoracic aortic tumor, and tissues obtained via endovascular biopsy revealed undifferentiated sarcoma. A final diagnosis of intimal sarcoma was made by intra-operative pathological examination. Despite undergoing surgical resection followed by adjuvant chemotherapy, the patient died from progressive multiple metastasis and severe sepsis. Although aortic sarcoma is rarely diagnosed, it should be considered a possible etiology of hypertensive crisis. PMID:27122923

  4. Computational Fluid Dynamics Analysis of Thoracic Aortic Dissection

    NASA Astrophysics Data System (ADS)

    Tang, Yik; Fan, Yi; Cheng, Stephen; Chow, Kwok

    2011-11-01

    Thoracic Aortic Dissection (TAD) is a cardiovascular disease with high mortality. An aortic dissection is formed when blood infiltrates the layers of the vascular wall, and a new artificial channel, the false lumen, is created. The expansion of the blood vessel due to the weakened wall enhances the risk of rupture. Computational fluid dynamics analysis is performed to study the hemodynamics of this pathological condition. Both idealized geometry and realistic patient configurations from computed tomography (CT) images are investigated. Physiological boundary conditions from in vivo measurements are employed. Flow configuration and biomechanical forces are studied. Quantitative analysis allows clinicians to assess the risk of rupture in making decision regarding surgical intervention.

  5. Volumetric limiting spatial resolution analysis of four dimensional digital subtraction angiography (4D-DSA)

    NASA Astrophysics Data System (ADS)

    Davis, Brian; Oberstar, Erick; Royalty, Kevin; Schafer, Sebastian; Strother, Charles; Mistretta, Charles

    2015-03-01

    Static C-Arm CT 3D FDK baseline reconstructions (3D-DSA) are unable to provide temporal information to radiologists. 4D-DSA provides a time series of 3D volumes implementing a constrained image, thresholded 3D-DSA, reconstruction utilizing temporal dynamics in the 2D projections. Volumetric limiting spatial resolution (VLSR) of 4DDSA is quantified and compared to a 3D-DSA reconstruction using the same 3D-DSA parameters. Investigated were the effects of varying over significant ranges the 4D-DSA parameters of 2D blurring kernel size applied to the projection and threshold applied to the 3D-DSA when generating the constraining image of a scanned phantom (SPH) and an electronic phantom (EPH). The SPH consisted of a 76 micron tungsten wire encased in a 47 mm O.D. plastic radially concentric thin walled support structure. An 8-second/248-frame/198° scan protocol acquired the raw projection data. VLSR was determined from averaged MTF curves generated from each 2D transverse slice of every (248) 4D temporal frame (3D). 4D results for SPH and EPH were compared to the 3D-DSA. Analysis of the 3D-DSA resulted in a VLSR of 2.28 and 1.69 lp/mm for the EPH and SPH respectively. Kernel (2D) sizes of either 10x10 or 20x20 pixels with a threshold of 10% of the 3D-DSA as a constraining image provided 4D-DSA VLSR nearest to the 3D-DSA. 4D-DSA algorithms yielded 2.21 and 1.67 lp/mm with a percent error of 3.1% and 1.2% for the EPH and SPH respectively as compared to the 3D-DSA. This research indicates 4D-DSA is capable of retaining the resolution of the 3D-DSA.

  6. [A case of thoracic actinomycosis].

    PubMed

    Denisova, O A; Cherniavskaia, G M; Beloborodova, É I; Topol'nitskiĭ, E B; Iakimenko, Iu V; Chernogoriuk, G É; Beloborodova, E V; Strezh, Iu A; Vil'danova, L R

    2014-01-01

    A case of thoracic actinomycosis manifest as round shadow in the lung is described. Diagnosis was based on the presence of actinomycetes in a transthoracic lung biopsy sample. Treatment for 3 months resulted in recovery. No relapse was documented during 1 year follow-up period. PMID:25265662

  7. Spinal dermoid sinus in a Dachshund with vertebral and thoracic limb malformations

    PubMed Central

    2014-01-01

    Background Dermoid sinus is an uncommon epithelial-lined fistula that may be associated with vertebral malformations. In humans, Klippel-Feil syndrome (KFS) is a rare condition characterized by congenital cervical vertebral fusion and may be associated with other developmental defects, including dermoid sinus. The present case report describes an adult Dachshund with cervical and cranial thoracic vertebral malformations as well as thoracic limb malformations resembling KFS with a concurrent type IV dermoid sinus. Case presentation A 1.5 year-old Dachshund with congenital thoracic limbs deformities and cervical-thoracic vertebral malformations presented with cervical hyperesthesia, rigidity of the cervical musculature and tetraparesis. Neurologic, radiographic, and computed tomography (CT) (2D, 3D, CT fistulography) examinations revealed skeletal anomalies, a dermoid sinus in the cranial thoracic region and epidural gas within the vertebral canal. Surgical resection and histopathological evaluation of the sinus tract were performed and confirmed a type IV dermoid sinus. The clinical signs progressively recovered postoperatively, and no recurrent signs were observed after 6 months of follow-up. Conclusions Cervical vertebral malformations associated with limbs anomalies have not been reported in dogs and may represent a condition similar to KFS in humans. KFS can occur concurrently with other congenital conditions including dermoid sinus and should be included among the complex congenital anomalies described in dogs. PMID:24593884

  8. Automated segmentation of pulmonary structures in thoracic computed tomography scans: a review

    NASA Astrophysics Data System (ADS)

    van Rikxoort, Eva M.; van Ginneken, Bram

    2013-09-01

    Computed tomography (CT) is the modality of choice for imaging the lungs in vivo. Sub-millimeter isotropic images of the lungs can be obtained within seconds, allowing the detection of small lesions and detailed analysis of disease processes. The high resolution of thoracic CT and the high prevalence of lung diseases require a high degree of automation in the analysis pipeline. The automated segmentation of pulmonary structures in thoracic CT has been an important research topic for over a decade now. This systematic review provides an overview of current literature. We discuss segmentation methods for the lungs, the pulmonary vasculature, the airways, including airway tree construction and airway wall segmentation, the fissures, the lobes and the pulmonary segments. For each topic, the current state of the art is summarized, and topics for future research are identified.

  9. C4d staining as immunohistochemical marker in inflammatory myopathies.

    PubMed

    Pytel, Peter

    2014-10-01

    The diagnosis of an inflammatory myopathy is often established based on basic histologic studies. Additional immunohistochemical studies are sometimes required to support the diagnosis and the classification of inflammatory myopathies. Staining for major histocompatibility complex 1 (MHC1) often shows increased sarcolemmal labeling in inflammatory myopathies. Endomysial capillary staining C5b-9 (membrane attack complex) is a feature that is reported as frequently associated with dermatomyositis. Immunohistochemical staining for C4d is widely used for various applications including the assessment of antibody-mediated rejection after solid organ transplantation. In the context of dermatomyositis, C4d staining has been described in skin biopsies but not in muscle biopsies. A total of 32 muscle biopsy specimens were examined. The hematoxylin and eosin-stained slides were reviewed, and immunohistochemical studies for MHC1, C5b-9, and C4d were conducted. The staining observed for C5b-9 and C4d was compared. Overall, the staining pattern for C4d mirrored the one observed for C5b-9 in the examined muscle biopsy specimens. There was high and statistically significant (P<0.0001) correlation between the staining seen with these 2 antibodies. Both antibodies labeled the cytoplasm of degenerating necrotic myofibers. In addition, both antibodies showed distinct endomysial capillary labeling in a subset of dermatomyositis. Areas with perifascicular atrophy often exhibited the most prominent vascular labeling for C4d and C5b-9. In conclusion, C4d and C5b-9 show similar expression patterns in muscle biopsies of patients with inflammatory myopathies and both highlight the presence of vascular labeling associated with dermatomyositis. C4d antibodies are widely used and may offer an alternative for C5b-9 staining.

  10. Endovascular Repair of Thoracic Aortic Aneurysms

    PubMed Central

    Findeiss, Laura K.; Cody, Michael E.

    2011-01-01

    Degenerative aneurysms of the thoracic aorta are increasing in prevalence; open repair of descending thoracic aortic aneurysms is associated with high rates of morbidity and mortality. Repair of isolated descending thoracic aortic aneurysms using stent grafts was introduced in 1995, and in an anatomically suitable subgroup of patients with thoracic aortic aneurysm, repair with endovascular stent graft provides favorable outcomes, with decreased perioperative morbidity and mortality relative to open repair. The cornerstones of successful thoracic endovascular aneurysm repair are appropriate patient selection, thorough preprocedural planning, and cautious procedural execution, the elements of which are discussed here. PMID:22379281

  11. Substitutional 4d and 5d impurities in graphene.

    PubMed

    Alonso-Lanza, Tomás; Ayuela, Andrés; Aguilera-Granja, Faustino

    2016-08-21

    We describe the structural and electronic properties of graphene doped with substitutional impurities of 4d and 5d transition metals. The adsorption energies and distances for 4d and 5d metals in graphene show similar trends for the later groups in the periodic table, which are also well-known characteristics of 3d elements. However, along earlier groups the 4d impurities in graphene show very similar adsorption energies, distances and magnetic moments to the 5d ones, which can be related to the influence of the 4d and 5d lanthanide contraction. Surprisingly, within the manganese group, the total magnetic moment of 3 μB for manganese is reduced to 1 μB for technetium and rhenium. We find that compared with 3d elements, the larger size of the 4d and 5d elements causes a high degree of hybridization with the neighbouring carbon atoms, reducing spin splitting in the d levels. It seems that the magnetic adjustment of graphene could be significantly different if 4d or 5d impurities are used instead of 3d impurities.

  12. Substitutional 4d and 5d impurities in graphene.

    PubMed

    Alonso-Lanza, Tomás; Ayuela, Andrés; Aguilera-Granja, Faustino

    2016-08-21

    We describe the structural and electronic properties of graphene doped with substitutional impurities of 4d and 5d transition metals. The adsorption energies and distances for 4d and 5d metals in graphene show similar trends for the later groups in the periodic table, which are also well-known characteristics of 3d elements. However, along earlier groups the 4d impurities in graphene show very similar adsorption energies, distances and magnetic moments to the 5d ones, which can be related to the influence of the 4d and 5d lanthanide contraction. Surprisingly, within the manganese group, the total magnetic moment of 3 μB for manganese is reduced to 1 μB for technetium and rhenium. We find that compared with 3d elements, the larger size of the 4d and 5d elements causes a high degree of hybridization with the neighbouring carbon atoms, reducing spin splitting in the d levels. It seems that the magnetic adjustment of graphene could be significantly different if 4d or 5d impurities are used instead of 3d impurities. PMID:27439363

  13. 4D offline PET-based treatment verification in scanned ion beam therapy: a phantom study

    NASA Astrophysics Data System (ADS)

    Kurz, Christopher; Bauer, Julia; Unholtz, Daniel; Richter, Daniel; Stützer, Kristin; Bert, Christoph; Parodi, Katia

    2015-08-01

    At the Heidelberg Ion-Beam Therapy Center, patient irradiation with scanned proton and carbon ion beams is verified by offline positron emission tomography (PET) imaging: the {β+} -activity measured within the patient is compared to a prediction calculated on the basis of the treatment planning data in order to identify potential delivery errors. Currently, this monitoring technique is limited to the treatment of static target structures. However, intra-fractional organ motion imposes considerable additional challenges to scanned ion beam radiotherapy. In this work, the feasibility and potential of time-resolved (4D) offline PET-based treatment verification with a commercial full-ring PET/CT (x-ray computed tomography) device are investigated for the first time, based on an experimental campaign with moving phantoms. Motion was monitored during the gated beam delivery as well as the subsequent PET acquisition and was taken into account in the corresponding 4D Monte-Carlo simulations and data evaluation. Under the given experimental conditions, millimeter agreement between the prediction and measurement was found. Dosimetric consequences due to the phantom motion could be reliably identified. The agreement between PET measurement and prediction in the presence of motion was found to be similar as in static reference measurements, thus demonstrating the potential of 4D PET-based treatment verification for future clinical applications.

  14. 4D offline PET-based treatment verification in scanned ion beam therapy: a phantom study.

    PubMed

    Kurz, Christopher; Bauer, Julia; Unholtz, Daniel; Richter, Daniel; Stützer, Kristin; Bert, Christoph; Parodi, Katia

    2015-08-21

    At the Heidelberg Ion-Beam Therapy Center, patient irradiation with scanned proton and carbon ion beams is verified by offline positron emission tomography (PET) imaging: the β+-activity measured within the patient is compared to a prediction calculated on the basis of the treatment planning data in order to identify potential delivery errors. Currently, this monitoring technique is limited to the treatment of static target structures. However, intra-fractional organ motion imposes considerable additional challenges to scanned ion beam radiotherapy. In this work, the feasibility and potential of time-resolved (4D) offline PET-based treatment verification with a commercial full-ring PET/CT (x-ray computed tomography) device are investigated for the first time, based on an experimental campaign with moving phantoms. Motion was monitored during the gated beam delivery as well as the subsequent PET acquisition and was taken into account in the corresponding 4D Monte-Carlo simulations and data evaluation. Under the given experimental conditions, millimeter agreement between the prediction and measurement was found. Dosimetric consequences due to the phantom motion could be reliably identified. The agreement between PET measurement and prediction in the presence of motion was found to be similar as in static reference measurements, thus demonstrating the potential of 4D PET-based treatment verification for future clinical applications. PMID:26237315

  15. Comparative evaluation of CT-based and PET/4DCT-based planning target volumes in the radiation of primary esophageal cancer

    PubMed Central

    Guo, Yan-Luan; Li, Jian-Bin; Shao, Qian; Li, Yan-Kang; Zhang, Peng

    2015-01-01

    Purpose: To compare planning target volume (PTV) defined by PET combined with 4DCT to 3DCT and 4DCT. Methods: Eighteen (18/30) esophageal cancer patients who underwent 3DCT, 4DCT and 18F-FDG PET-CT thoracic simulation with SUVmax≥2.0 of the primary volume were enrolled. CTV3D was formed on 3DCT by adding a margin of 30 mm in cranial-caudal direction and 5 mm in transversal direction. PTV3D was defined using a 10 mm margin to CTV3D and CTV4D was obtained by fusion of CTV from ten phases of 4DCT. A 5 mm margin for setup errors to CTV4D was to form PTV4D. BTVPET was generated with the assumption that motion was captured in PET images using a thresholding methods: 20% SUVmax. CTVPET 4DCT was calculated by the union of BTVPET and CTV4D, and a 5 mm margin to CTVPET 4DCT was used to form PTVPET 4DCT. The geometrical differences of the targets were evaluated. Results: Statistically significant differences were observed among CTV3D, CTV4D and CTVPET 4DCT (CTVPET 4DCT>CTV4D>CTV3D, P=0.000-0.038). PTV3D, PTV4D, and PTVPET 4DCT also differed significantly from each other (PTVPET 4DCT>PTV4D>PTV3D, P=0.000-0.048). The DI of PTV3D in PTVPET 4DCT was significantly larger than that of PTV3D in PTV 4D (P=0.042). There were no significant differences between the DI of PTV4D in PTV3D and PTVPET 4DCT in PTV3D (P=0.118). Conclusions: As demonstrated by the assessment of the geometrical differences in PET/4DCT-based and 3DCT-based PTV, PET/4DCT could affect not only the volume of PTV but also its shape. PMID:26885100

  16. Effect of thoracic arthrodesis in prepubertal New Zealand white rabbits on cardio-pulmonary function

    PubMed Central

    Canavese, Federico; Dimeglio, Alain; Barbetta, Davide; Pereira, Bruno; Fabbro, Sergio; Bassini, Federica; Canavese, Bartolomeo

    2014-01-01

    Background: This experimental study was aimed at evaluating the type of cardiac and pulmonary involvement, in relation to changes of the thoracic spine and cage in prepubertal rabbits with nondeformed spine following dorsal arthrodesis. The hypothesis was that T1-T12 arthrodesis modified thoracic dimensions, but would not modify cardiopulmonary function once skeletal maturity was reached. Materials and Methods: The study was conducted in 16 female New Zealand White (NZW) rabbits. Nine rabbits were subjected to T1-T12 dorsal arthrodesis while seven were sham-operated. Echocardiographic images were obtained at 12 months after surgery and parameters for 2-dimensional and M-mode echocardiographic variables were assessed. One week before echocardiographic examination, blood samples were withdrawn from the animals’ central artery of the left ear to obtain blood gas values. One week after echocardiographic assessment, a thoracic CT scan was performed under general anesthesia. Chest depth (CD) and width (CW), thoracic kyphosis (ThK) and sternal length (StL) were measured; thoracic index (ThI), expressed as CD/CW ratio. All subjects were euthanized after the CT scan. Heart and lungs were subsequently removed to measure weight and volume. Results: The values for 2-dimensional and M-mode echocardiographic variables were found to be uniformly and significantly higher, compared to those reported in anesthetized rabbits. CD, ThK, and StL were considerably lower in operated rabbits, as compared to the ones that were sham-operated. Similarly, the ThI was lower in operated rabbits than in sham-operated ones. Conclusion: Irregularities in thoracic cage growth resulting from thoracic spine arthrodesis did not alter blood and echocardiographic parameters in NZW rabbits. PMID:24741141

  17. Quantitative analysis of tomotherapy, linear-accelerator-based 3D conformal radiation therapy, intensity-modulated radiation therapy, and 4D conformal radiation therapy

    NASA Astrophysics Data System (ADS)

    Cho, Jae-Hwan; Lee, Hae-Kag; Dong, Kyung-Rae; Chung, Woon-Kwan; Lee, Jong-Woong; Park, Hoon-Hee

    2012-04-01

    This study quantified, evaluated and analyzed the radiation dose to which tumors and normal tissues were exposed in 3D conformal radiation therapy (CRT), intensity-modulated radiation therapy (IMRT) and tomotherapy by using a dose volume histogram (DVH) that represented the volume dose and the dose distribution of anatomical structures in the evaluation of treatment planning. Furthermore, a comparison was made for the dose to the gross tumor volume (GTV) and the planning target volume (PTV) of organ to be treated based on the change in field size for three- and four-dimensional computed tomography (3D-CT and 4D-CT) (gating based) and in the histogram with a view to proving the usefulness of 4D-CT therapy, which corresponds to respiration-gated radiation therapy. According to the study results, a comparison of 3D CRT, IMRT with a linear accelerator (LINAC), and tomotherapy demonstrated that the GTV of the cranium was higher for tomotherapy than for 3D CRT and IMRT with a LINAC by 5.2% and 4.6%, respectively. The GTV of the neck was higher for tomotherapy than for 3D CRT and IMRT with a LINAC by 6.5% and 2.0%, respectively. The GTV of the pelvis was higher for tomotherapy than for 3D CRT and IMRT with a LINAC by 8.6% and 3.7%, respectively. When the comparison was made for the 3D-CT and the 4D-CT (gating based) treatment equipment, the GTV and the PTV became smaller for 4D-CT treatment planning than for 3D-CT, which could reduce the area in which normal tissues in the surroundings are exposed to an unnecessary radiation dose. In addition, when 4D-CT treatment planning (gating based) was used, the radiation dose could be concentrated on the GTV, CTV or PTV, which meant that the treatment area exceeded that when 3D-CT's treatment planning was used. Moreover, the radiation dose on nearby normal tissues could be reduced. When 4D-CT treatment planning (gating based) was utilized, unnecessary areas that were exposed to a radiation dose could be reduced more than they could

  18. Motion-aware temporal regularization for improved 4D cone-beam computed tomography

    NASA Astrophysics Data System (ADS)

    Mory, Cyril; Janssens, Guillaume; Rit, Simon

    2016-09-01

    Four-dimensional cone-beam computed tomography (4D-CBCT) of the free-breathing thorax is a valuable tool in image-guided radiation therapy of the thorax and the upper abdomen. It allows the determination of the position of a tumor throughout the breathing cycle, while only its mean position can be extracted from three-dimensional CBCT. The classical approaches are not fully satisfactory: respiration-correlated methods allow one to accurately locate high-contrast structures in any frame, but contain strong streak artifacts unless the acquisition is significantly slowed down. Motion-compensated methods can yield streak-free, but static, reconstructions. This work proposes a 4D-CBCT method that can be seen as a trade-off between respiration-correlated and motion-compensated reconstruction. It builds upon the existing reconstruction using spatial and temporal regularization (ROOSTER) and is called motion-aware ROOSTER (MA-ROOSTER). It performs temporal regularization along curved trajectories, following the motion estimated on a prior 4D CT scan. MA-ROOSTER does not involve motion-compensated forward and back projections: the input motion is used only during temporal regularization. MA-ROOSTER is compared to ROOSTER, motion-compensated Feldkamp–Davis–Kress (MC-FDK), and two respiration-correlated methods, on CBCT acquisitions of one physical phantom and two patients. It yields streak-free reconstructions, visually similar to MC-FDK, and robust information on tumor location throughout the breathing cycle. MA-ROOSTER also allows a variation of the lung tissue density during the breathing cycle, similar to that of planning CT, which is required for quantitative post-processing.

  19. Motion-aware temporal regularization for improved 4D cone-beam computed tomography

    NASA Astrophysics Data System (ADS)

    Mory, Cyril; Janssens, Guillaume; Rit, Simon

    2016-09-01

    Four-dimensional cone-beam computed tomography (4D-CBCT) of the free-breathing thorax is a valuable tool in image-guided radiation therapy of the thorax and the upper abdomen. It allows the determination of the position of a tumor throughout the breathing cycle, while only its mean position can be extracted from three-dimensional CBCT. The classical approaches are not fully satisfactory: respiration-correlated methods allow one to accurately locate high-contrast structures in any frame, but contain strong streak artifacts unless the acquisition is significantly slowed down. Motion-compensated methods can yield streak-free, but static, reconstructions. This work proposes a 4D-CBCT method that can be seen as a trade-off between respiration-correlated and motion-compensated reconstruction. It builds upon the existing reconstruction using spatial and temporal regularization (ROOSTER) and is called motion-aware ROOSTER (MA-ROOSTER). It performs temporal regularization along curved trajectories, following the motion estimated on a prior 4D CT scan. MA-ROOSTER does not involve motion-compensated forward and back projections: the input motion is used only during temporal regularization. MA-ROOSTER is compared to ROOSTER, motion-compensated Feldkamp-Davis-Kress (MC-FDK), and two respiration-correlated methods, on CBCT acquisitions of one physical phantom and two patients. It yields streak-free reconstructions, visually similar to MC-FDK, and robust information on tumor location throughout the breathing cycle. MA-ROOSTER also allows a variation of the lung tissue density during the breathing cycle, similar to that of planning CT, which is required for quantitative post-processing.

  20. Application of adaptive kinetic modelling for bias propagation reduction in direct 4D image reconstruction

    NASA Astrophysics Data System (ADS)

    Kotasidis, F. A.; Matthews, J. C.; Reader, A. J.; Angelis, G. I.; Zaidi, H.

    2014-10-01

    Parametric imaging in thoracic and abdominal PET can provide additional parameters more relevant to the pathophysiology of the system under study. However, dynamic data in the body are noisy due to the limiting counting statistics leading to suboptimal kinetic parameter estimates. Direct 4D image reconstruction algorithms can potentially improve kinetic parameter precision and accuracy in dynamic PET body imaging. However, construction of a common kinetic model is not always feasible and in contrast to post-reconstruction kinetic analysis, errors in poorly modelled regions may spatially propagate to regions which are well modelled. To reduce error propagation from erroneous model fits, we implement and evaluate a new approach to direct parameter estimation by incorporating a recently proposed kinetic modelling strategy within a direct 4D image reconstruction framework. The algorithm uses a secondary more general model to allow a less constrained model fit in regions where the kinetic model does not accurately describe the underlying kinetics. A portion of the residuals then is adaptively included back into the image whilst preserving the primary model characteristics in other well modelled regions using a penalty term that trades off the models. Using fully 4D simulations based on dynamic [15O]H2O datasets, we demonstrate reduction in propagation-related bias for all kinetic parameters. Under noisy conditions, reductions in bias due to propagation are obtained at the cost of increased noise, which in turn results in increased bias and variance of the kinetic parameters. This trade-off reflects the challenge of separating the residuals arising from poor kinetic modelling fits from the residuals arising purely from noise. Nonetheless, the overall root mean square error is reduced in most regions and parameters. Using the adaptive 4D image reconstruction improved model fits can be obtained in poorly modelled regions, leading to reduced errors potentially propagating

  1. Semaphorin 4D Promotes Skeletal Metastasis in Breast Cancer.

    PubMed

    Yang, Ying-Hua; Buhamrah, Asma; Schneider, Abraham; Lin, Yi-Ling; Zhou, Hua; Bugshan, Amr; Basile, John R

    2016-01-01

    Bone density is controlled by interactions between osteoclasts, which resorb bone, and osteoblasts, which deposit it. The semaphorins and their receptors, the plexins, originally shown to function in the immune system and to provide chemotactic cues for axon guidance, are now known to play a role in this process as well. Emerging data have identified Semaphorin 4D (Sema4D) as a product of osteoclasts acting through its receptor Plexin-B1 on osteoblasts to inhibit their function, tipping the balance of bone homeostasis in favor of resorption. Breast cancers and other epithelial malignancies overexpress Sema4D, so we theorized that tumor cells could be exploiting this pathway to establish lytic skeletal metastases. Here, we use measurements of osteoblast and osteoclast differentiation and function in vitro and a mouse model of skeletal metastasis to demonstrate that both soluble Sema4D and protein produced by the breast cancer cell line MDA-MB-231 inhibits differentiation of MC3T3 cells, an osteoblast cell line, and their ability to form mineralized tissues, while Sema4D-mediated induction of IL-8 and LIX/CXCL5, the murine homologue of IL-8, increases osteoclast numbers and activity. We also observe a decrease in the number of bone metastases in mice injected with MDA-MB-231 cells when Sema4D is silenced by RNA interference. These results are significant because treatments directed at suppression of skeletal metastases in bone-homing malignancies usually work by arresting bone remodeling, potentially leading to skeletal fragility, a significant problem in patient management. Targeting Sema4D in these cancers would not affect bone remodeling and therefore could elicit an improved therapeutic result without the debilitating side effects.

  2. Soil matrix and macropore biodegradation of 2,4-D

    SciTech Connect

    Pivetz, B.E.; Steenhuis, T.S.

    1995-07-01

    Preferential flow of pesticides in macropores can lead to decreased travel times through the vadose zone and increased groundwater contamination. Macropores, however, may present a favorable environment for biodegradation because of greater oxygen, nutrient, and substrate supply, and higher microbial populations in earthworm burrows, compared to the soil matrix. The biodegradation of 2,4-dichlorophenoxyacetic acid (2,4-D) was measured in macropores and soil matrix of packed soil columns (7.0-cm diam., 10-cm length) and undisturbed cores contained as well-defined artificial macropore and the undisturbed cores contained earthworm-burrow macropores. A 50 {mu}g/L 2,4-D solution was continuously applied to the unsaturated soil surface and breakthrough curves (BTCs) indicating pesticide loss in the effluent were obtained from the soil matrix and macropore flow paths. Biodegradation rates were calculated separately for each flow path by comparing the BTCs to BTCs representing abiotic conditions, and dividing the 2,4-D loss by the travel time through each flow path. The biodegradation rates increased with time in both flow paths, and the final biodegradation rate in the macropore region surpassed that of the matrix, presumably because of increased microbial populations in the macropore. Complete loss of the 2,4-D in both flow paths was observed after continuous application of 2,4-D for 400 h, with maximum column-averaged 2,4-D loss rates of 0.879 {mu}g/(L h) in the matrix and 1.073 {mu}g/(L h) in the macropore. Biodegradation of 2,4-D was also observed in the macropore and matrix regions of the undisturbed soil cores. 19 refs., 7 figs., 2 tabs.

  3. Semaphorin 4D Promotes Skeletal Metastasis in Breast Cancer

    PubMed Central

    Yang, Ying-Hua; Buhamrah, Asma; Schneider, Abraham; Lin, Yi-Ling; Zhou, Hua; Bugshan, Amr; Basile, John R.

    2016-01-01

    Bone density is controlled by interactions between osteoclasts, which resorb bone, and osteoblasts, which deposit it. The semaphorins and their receptors, the plexins, originally shown to function in the immune system and to provide chemotactic cues for axon guidance, are now known to play a role in this process as well. Emerging data have identified Semaphorin 4D (Sema4D) as a product of osteoclasts acting through its receptor Plexin-B1 on osteoblasts to inhibit their function, tipping the balance of bone homeostasis in favor of resorption. Breast cancers and other epithelial malignancies overexpress Sema4D, so we theorized that tumor cells could be exploiting this pathway to establish lytic skeletal metastases. Here, we use measurements of osteoblast and osteoclast differentiation and function in vitro and a mouse model of skeletal metastasis to demonstrate that both soluble Sema4D and protein produced by the breast cancer cell line MDA-MB-231 inhibits differentiation of MC3T3 cells, an osteoblast cell line, and their ability to form mineralized tissues, while Sema4D-mediated induction of IL-8 and LIX/CXCL5, the murine homologue of IL-8, increases osteoclast numbers and activity. We also observe a decrease in the number of bone metastases in mice injected with MDA-MB-231 cells when Sema4D is silenced by RNA interference. These results are significant because treatments directed at suppression of skeletal metastases in bone-homing malignancies usually work by arresting bone remodeling, potentially leading to skeletal fragility, a significant problem in patient management. Targeting Sema4D in these cancers would not affect bone remodeling and therefore could elicit an improved therapeutic result without the debilitating side effects. PMID:26910109

  4. A technique for estimating 4D-CBCT using prior knowledge and limited-angle projections

    SciTech Connect

    Zhang, You; Yin, Fang-Fang; Ren, Lei; Segars, W. Paul

    2013-12-15

    Purpose: To develop a technique to estimate onboard 4D-CBCT using prior information and limited-angle projections for potential 4D target verification of lung radiotherapy.Methods: Each phase of onboard 4D-CBCT is considered as a deformation from one selected phase (prior volume) of the planning 4D-CT. The deformation field maps (DFMs) are solved using a motion modeling and free-form deformation (MM-FD) technique. In the MM-FD technique, the DFMs are estimated using a motion model which is extracted from planning 4D-CT based on principal component analysis (PCA). The motion model parameters are optimized by matching the digitally reconstructed radiographs of the deformed volumes to the limited-angle onboard projections (data fidelity constraint). Afterward, the estimated DFMs are fine-tuned using a FD model based on data fidelity constraint and deformation energy minimization. The 4D digital extended-cardiac-torso phantom was used to evaluate the MM-FD technique. A lung patient with a 30 mm diameter lesion was simulated with various anatomical and respirational changes from planning 4D-CT to onboard volume, including changes of respiration amplitude, lesion size and lesion average-position, and phase shift between lesion and body respiratory cycle. The lesions were contoured in both the estimated and “ground-truth” onboard 4D-CBCT for comparison. 3D volume percentage-difference (VPD) and center-of-mass shift (COMS) were calculated to evaluate the estimation accuracy of three techniques: MM-FD, MM-only, and FD-only. Different onboard projection acquisition scenarios and projection noise levels were simulated to investigate their effects on the estimation accuracy.Results: For all simulated patient and projection acquisition scenarios, the mean VPD (±S.D.)/COMS (±S.D.) between lesions in prior images and “ground-truth” onboard images were 136.11% (±42.76%)/15.5 mm (±3.9 mm). Using orthogonal-view 15°-each scan angle, the mean VPD/COMS between the lesion

  5. Scatter correction of vessel dropout behind highly attenuating structures in 4D-DSA

    NASA Astrophysics Data System (ADS)

    Hermus, James; Mistretta, Charles; Szczykutowicz, Timothy P.

    2015-03-01

    In Computed Tomographic (CT) image reconstruction for 4 dimensional digital subtraction angiography (4D-DSA), loss of vessel contrast has been observed behind highly attenuating anatomy, such as large contrast filled aneurysms. Although this typically occurs only in a limited range of projection angles, the observed contrast time course can be altered. In this work we propose an algorithm to correct for highly attenuating anatomy within the fill projection data, i.e. aneurysms. The algorithm uses a 3D-SA volume to create a correction volume that is multiplied by the 4D-DSA volume in order to correct for signal dropout within the 4D-DSA volume. The algorithm was designed to correct for highly attenuating material in the fill volume only, however with alterations to a single step of the algorithm, artifacts due to highly attenuating materials in the mask volume (i.e. dental implants) can be mitigated as well. We successfully applied our algorithm to a case of vessel dropout due to the presence of a large attenuating aneurysm. The performance was qualified visually as the affected vessel no longer dropped out on corrected 4D-DSA time frames. The correction was quantified by plotting the signal intensity along the vessel. Our analysis demonstrated our correction does not alter vessel signal values outside of the vessel dropout region but does increase the vessel values within the dropout region as expected. We have demonstrated that this correction algorithm acts to correct vessel dropout in areas with highly attenuating materials.

  6. Tumor control probability and the utility of 4D vs 3D dose calculations for stereotactic body radiotherapy for lung cancer.

    PubMed

    Valdes, Gilmer; Robinson, Clifford; Lee, Percy; Morel, Delphine; Low, Daniel; Iwamoto, Keisuke S; Lamb, James M

    2015-01-01

    Four-dimensional (4D) dose calculations for lung cancer radiotherapy have been technically feasible for a number of years but have not become standard clinical practice. The purpose of this study was to determine if clinically significant differences in tumor control probability (TCP) exist between 3D and 4D dose calculations so as to inform the decision whether 4D dose calculations should be used routinely for treatment planning. Radiotherapy plans for Stage I-II lung cancer were created for 8 patients. Clinically acceptable treatment plans were created with dose calculated on the end-exhale 4D computed tomography (CT) phase using a Monte Carlo algorithm. Dose was then projected onto the remaining 9 phases of 4D-CT using the Monte Carlo algorithm and accumulated onto the end-exhale phase using commercially available deformable registration software. The resulting dose-volume histograms (DVH) of the gross tumor volume (GTV), planning tumor volume (PTV), and PTVsetup were compared according to target coverage and dose. The PTVsetup was defined as a volume including the GTV and a margin for setup uncertainties but not for respiratory motion. TCPs resulting from these DVHs were estimated using a wide range of alphas, betas, and tumor cell densities. Differences of up to 5Gy were observed between 3D and 4D calculations for a PTV with highly irregular shape. When the TCP was calculated using the resulting DVHs for fractionation schedules typically used in stereotactic body radiation therapy (SBRT), the TCP differed at most by 5% between 4D and 3D cases, and in most cases, it was by less than 1%. We conclude that 4D dose calculations are not necessary for most cases treated with SBRT, but they might be valuable for irregularly shaped target volumes. If 4D calculations are used, 4D DVHs should be evaluated on volumes that include margin for setup uncertainty but not respiratory motion.

  7. Tumor control probability and the utility of 4D vs 3D dose calculations for stereotactic body radiotherapy for lung cancer

    SciTech Connect

    Valdes, Gilmer; Robinson, Clifford; Lee, Percy; Morel, Delphine; Low, Daniel; Iwamoto, Keisuke S.; Lamb, James M.

    2015-04-01

    Four-dimensional (4D) dose calculations for lung cancer radiotherapy have been technically feasible for a number of years but have not become standard clinical practice. The purpose of this study was to determine if clinically significant differences in tumor control probability (TCP) exist between 3D and 4D dose calculations so as to inform the decision whether 4D dose calculations should be used routinely for treatment planning. Radiotherapy plans for Stage I-II lung cancer were created for 8 patients. Clinically acceptable treatment plans were created with dose calculated on the end-exhale 4D computed tomography (CT) phase using a Monte Carlo algorithm. Dose was then projected onto the remaining 9 phases of 4D-CT using the Monte Carlo algorithm and accumulated onto the end-exhale phase using commercially available deformable registration software. The resulting dose-volume histograms (DVH) of the gross tumor volume (GTV), planning tumor volume (PTV), and PTV{sub setup} were compared according to target coverage and dose. The PTV{sub setup} was defined as a volume including the GTV and a margin for setup uncertainties but not for respiratory motion. TCPs resulting from these DVHs were estimated using a wide range of alphas, betas, and tumor cell densities. Differences of up to 5 Gy were observed between 3D and 4D calculations for a PTV with highly irregular shape. When the TCP was calculated using the resulting DVHs for fractionation schedules typically used in stereotactic body radiation therapy (SBRT), the TCP differed at most by 5% between 4D and 3D cases, and in most cases, it was by less than 1%. We conclude that 4D dose calculations are not necessary for most cases treated with SBRT, but they might be valuable for irregularly shaped target volumes. If 4D calculations are used, 4D DVHs should be evaluated on volumes that include margin for setup uncertainty but not respiratory motion.

  8. CT -- Body

    MedlinePlus

    ... News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Body Computed tomography (CT) of the body uses special x-ray ... Body? What is CT Scanning of the Body? Computed tomography, more commonly known as a CT or CAT ...

  9. Automatic detection of lung vessel bifurcation in thoracic CT images

    NASA Astrophysics Data System (ADS)

    Maduskar, Pragnya; Vikal, Siddharth; Devarakota, Pandu

    2011-03-01

    Computer-aided diagnosis (CAD) systems for detection of lung nodules have been an active topic of research for last few years. It is desirable that a CAD system should generate very low false positives (FPs) while maintaining high sensitivity. This work aims to reduce the number of false positives occurring at vessel bifurcation point. FPs occur quite frequently on vessel branching point due to its shape which can appear locally spherical due to the intrinsic geometry of intersecting tubular vessel structures combined with partial volume effects and soft tissue attenuation appearance surrounded by parenchyma. We propose a model-based technique for detection of vessel branching points using skeletonization, followed by branch-point analysis. First we perform vessel structure enhancement using a multi-scale Hessian filter to accurately segment tubular structures of various sizes followed by thresholding to get binary vessel structure segmentation [6]. A modified Reebgraph [7] is applied next to extract the critical points of structure and these are joined by a nearest neighbor criterion to obtain complete skeletal model of vessel structure. Finally, the skeletal model is traversed to identify branch points, and extract metrics including individual branch length, number of branches and angle between various branches. Results on 80 sub-volumes consisting of 60 actual vessel-branching and 20 solitary solid nodules show that the algorithm identified correctly vessel branching points for 57 sub-volumes (95% sensitivity) and misclassified 2 nodules as vessel branch. Thus, this technique has potential in explicit identification of vessel branching points for general vessel analysis, and could be useful in false positive reduction in a lung CAD system.

  10. 4D cone beam CT-based dose assessment for SBRT lung cancer treatment.

    PubMed

    Cai, Weixing; Dhou, Salam; Cifter, Fulya; Myronakis, Marios; Hurwitz, Martina H; Williams, Christopher L; Berbeco, Ross I; Seco, Joao; Lewis, John H

    2016-01-21

    The purpose of this research is to develop a 4DCBCT-based dose assessment method for calculating actual delivered dose for patients with significant respiratory motion or anatomical changes during the course of SBRT. To address the limitation of 4DCT-based dose assessment, we propose to calculate the delivered dose using time-varying ('fluoroscopic') 3D patient images generated from a 4DCBCT-based motion model. The method includes four steps: (1) before each treatment, 4DCBCT data is acquired with the patient in treatment position, based on which a patient-specific motion model is created using a principal components analysis algorithm. (2) During treatment, 2D time-varying kV projection images are continuously acquired, from which time-varying 'fluoroscopic' 3D images of the patient are reconstructed using the motion model. (3) Lateral truncation artifacts are corrected using planning 4DCT images. (4) The 3D dose distribution is computed for each timepoint in the set of 3D fluoroscopic images, from which the total effective 3D delivered dose is calculated by accumulating deformed dose distributions. This approach is validated using six modified XCAT phantoms with lung tumors and different respiratory motions derived from patient data. The estimated doses are compared to that calculated using ground-truth XCAT phantoms. For each XCAT phantom, the calculated delivered tumor dose values generally follow the same trend as that of the ground truth and at most timepoints the difference is less than 5%. For the overall delivered dose, the normalized error of calculated 3D dose distribution is generally less than 3% and the tumor D95 error is less than 1.5%. XCAT phantom studies indicate the potential of the proposed method to accurately estimate 3D tumor dose distributions for SBRT lung treatment based on 4DCBCT imaging and motion modeling. Further research is necessary to investigate its performance for clinical patient data.

  11. 4D cone beam CT-based dose assessment for SBRT lung cancer treatment

    NASA Astrophysics Data System (ADS)

    Cai, Weixing; Dhou, Salam; Cifter, Fulya; Myronakis, Marios; Hurwitz, Martina H.; Williams, Christopher L.; Berbeco, Ross I.; Seco, Joao; Lewis, John H.

    2016-01-01

    The purpose of this research is to develop a 4DCBCT-based dose assessment method for calculating actual delivered dose for patients with significant respiratory motion or anatomical changes during the course of SBRT. To address the limitation of 4DCT-based dose assessment, we propose to calculate the delivered dose using time-varying (‘fluoroscopic’) 3D patient images generated from a 4DCBCT-based motion model. The method includes four steps: (1) before each treatment, 4DCBCT data is acquired with the patient in treatment position, based on which a patient-specific motion model is created using a principal components analysis algorithm. (2) During treatment, 2D time-varying kV projection images are continuously acquired, from which time-varying ‘fluoroscopic’ 3D images of the patient are reconstructed using the motion model. (3) Lateral truncation artifacts are corrected using planning 4DCT images. (4) The 3D dose distribution is computed for each timepoint in the set of 3D fluoroscopic images, from which the total effective 3D delivered dose is calculated by accumulating deformed dose distributions. This approach is validated using six modified XCAT phantoms with lung tumors and different respiratory motions derived from patient data. The estimated doses are compared to that calculated using ground-truth XCAT phantoms. For each XCAT phantom, the calculated delivered tumor dose values generally follow the same trend as that of the ground truth and at most timepoints the difference is less than 5%. For the overall delivered dose, the normalized error of calculated 3D dose distribution is generally less than 3% and the tumor D95 error is less than 1.5%. XCAT phantom studies indicate the potential of the proposed method to accurately estimate 3D tumor dose distributions for SBRT lung treatment based on 4DCBCT imaging and motion modeling. Further research is necessary to investigate its performance for clinical patient data.

  12. 4-D reconstruction for dynamic fluorescence diffuse optical tomography.

    PubMed

    Liu, Xin; Zhang, Bin; Luo, Jianwen; Bai, Jing

    2012-11-01

    Dynamic fluorescence diffuse optical tomography (FDOT) is important for the research of drug delivery, medical diagnosis and treatment. Conventionally, dynamic tomographic images are reconstructed frame by frame, independently. This approach fails to account for the temporal correlations in measurement data. Ideally, the entire image sequence should be considered as a whole and a four-dimensional (4-D) reconstruction should be performed. However, the fully 4-D reconstruction is computationally intensive. In this paper, we propose a new 4-D reconstruction approach for dynamic FDOT, which is achieved by applying a temporal Karhunen-Loève (KL) transformation to the imaging equation. By taking advantage of the decorrelation and compression properties of the KL transformation, the complex 4-D optical reconstruction problem is greatly simplified. To evaluate the performance of the method, simulation, phantom, and in vivo experiments (N=7) are performed on a hybrid FDOT/x-ray computed tomography imaging system. The experimental results indicate that the reconstruction images obtained by the KL method provide good reconstruction quality. Additionally, by discarding high-order KL components, the computation time involved with fully 4-D reconstruction can be greatly reduced in contrast to the conventional frame-by-frame reconstruction.

  13. New C4D Sensor with a Simulated Inductor

    PubMed Central

    Lyu, Yingchao; Ji, Haifeng; Yang, Shijie; Huang, Zhiyao; Wang, Baoliang; Li, Haiqing

    2016-01-01

    A new capacitively coupled contactless conductivity detection (C4D) sensor with an improved simulated inductor is developed in this work. The improved simulated inductor is designed on the basis of the Riordan-type floating simulated inductor. With the improved simulated inductor, the negative influence of the coupling capacitances is overcome and the conductivity measurement is implemented by the series resonance principle. The conductivity measurement experiments are carried out in three pipes with different inner diameters of 3.0 mm, 4.6 mm and 6.4 mm, respectively. The experimental results show that the designs of the new C4D sensor and the improved simulated inductor are successful. The maximum relative error of the conductivity measurement is less than 5%. Compared with the C4D sensors using practical inductors, the measurement accuracy of the new C4D sensor is comparable. The research results also indicate that the adjustability of a simulated inductor can reduce the requirement for the AC source and guarantee the interchangeableness. Meanwhile, it is recommended that making the potential of one terminal of a simulated inductor stable is beneficial to the running stability. Furthermore, this work indirectly verifies the possibility and feasibility of the miniaturization of the C4D sensor by using the simulated inductor technique and lays a good foundation for future research work. PMID:26828493

  14. Robotic Surgery for Thoracic Disease

    PubMed Central

    Yoshida, Yasuhiro; Iwasaki, Akinori

    2016-01-01

    Robotic surgeries have developed in the general thoracic field over the past decade, and publications on robotic surgery outcomes have accumulated. However, controversy remains about the application of robotic surgery, with a lack of well-established evidence. Robotic surgery has several advantages such as natural movement of the surgeon’s hands when manipulating the robotic arms and instruments controlled by computer-assisted systems. Most studies have reported the feasibility and safety of robotic surgery based on acceptable morbidity and mortality compared to open or video-assisted thoracic surgery (VATS). Furthermore, there are accumulated data to indicate longer operation times and shorter hospital stay in robotic surgery. However, randomized controlled trials between robotic and open or VATS procedures are needed to clarify the advantage of robotic surgery. In this review, we focused the literature about robotic surgery used to treat lung cancer and mediastinal tumor. PMID:26822625

  15. SU-E-J-200: A Dosimetric Analysis of 3D Versus 4D Image-Based Dose Calculation for Stereotactic Body Radiation Therapy in Lung Tumors

    SciTech Connect

    Ma, M; Rouabhi, O; Flynn, R; Xia, J; Bayouth, J

    2014-06-01

    Purpose: To evaluate the dosimetric difference between 3D and 4Dweighted dose calculation using patient specific respiratory trace and deformable image registration for stereotactic body radiation therapy in lung tumors. Methods: Two dose calculation techniques, 3D and 4D-weighed dose calculation, were used for dosimetric comparison for 9 lung cancer patients. The magnitude of the tumor motion varied from 3 mm to 23 mm. Breath-hold exhale CT was used for 3D dose calculation with ITV generated from the motion observed from 4D-CT. For 4D-weighted calculation, dose of each binned CT image from the ten breathing amplitudes was first recomputed using the same planning parameters as those used in the 3D calculation. The dose distribution of each binned CT was mapped to the breath-hold CT using deformable image registration. The 4D-weighted dose was computed by summing the deformed doses with the temporal probabilities calculated from their corresponding respiratory traces. Dosimetric evaluation criteria includes lung V20, mean lung dose, and mean tumor dose. Results: Comparing with 3D calculation, lung V20, mean lung dose, and mean tumor dose using 4D-weighted dose calculation were changed by −0.67% ± 2.13%, −4.11% ± 6.94% (−0.36 Gy ± 0.87 Gy), −1.16% ± 1.36%(−0.73 Gy ± 0.85 Gy) accordingly. Conclusion: This work demonstrates that conventional 3D dose calculation method may overestimate the lung V20, MLD, and MTD. The absolute difference between 3D and 4D-weighted dose calculation in lung tumor may not be clinically significant. This research is supported by Siemens Medical Solutions USA, Inc and Iowa Center for Research By Undergraduates.

  16. Nanotechnology applications in thoracic surgery.

    PubMed

    Hofferberth, Sophie C; Grinstaff, Mark W; Colson, Yolonda L

    2016-07-01

    Nanotechnology is an emerging, rapidly evolving field with the potential to significantly impact care across the full spectrum of cancer therapy. Of note, several recent nanotechnological advances show particular promise to improve outcomes for thoracic surgical patients. A variety of nanotechnologies are described that offer possible solutions to existing challenges encountered in the detection, diagnosis and treatment of lung cancer. Nanotechnology-based imaging platforms have the ability to improve the surgical care of patients with thoracic malignancies through technological advances in intraoperative tumour localization, lymph node mapping and accuracy of tumour resection. Moreover, nanotechnology is poised to revolutionize adjuvant lung cancer therapy. Common chemotherapeutic drugs, such as paclitaxel, docetaxel and doxorubicin, are being formulated using various nanotechnologies to improve drug delivery, whereas nanoparticle (NP)-based imaging technologies can monitor the tumour microenvironment and facilitate molecularly targeted lung cancer therapy. Although early nanotechnology-based delivery systems show promise, the next frontier in lung cancer therapy is the development of 'theranostic' multifunctional NPs capable of integrating diagnosis, drug monitoring, tumour targeting and controlled drug release into various unifying platforms. This article provides an overview of key existing and emerging nanotechnology platforms that may find clinical application in thoracic surgery in the near future. PMID:26843431

  17. A 4D Hyperspherical Interpretation of q-Space

    PubMed Central

    Hosseinbor, A. Pasha; Chung, Moo K.; Wu, Yu-Chien; Alexander, Andrew L.; Bendlin, Barbara B.

    2014-01-01

    3D q-space can be viewed as the surface of a 4D hypersphere. In this paper, we seek to develop a 4D hyperspherical interpretation of q-space by projecting it onto a hypersphere and subsequently modeling the q-space signal via 4D hyperspherical harmonics (HSH). Using this orthonormal basis, we analytically derive several quantitative indices and numerically estimate the diffusion ODF. Importantly, we derive the integral transform describing the relationship between the diffusion signal and propagator on a hypersphere. We also show that the HSH basis expends less fitting parameters than other well-established methods to achieve comparable signal and better ODF reconstructions. All in all, this work provides a new way of looking at q-space. PMID:24505799

  18. Four-dimensional magnetic resonance imaging (4D-MRI) using image-based respiratory surrogate: A feasibility study

    PubMed Central

    Cai, Jing; Chang, Zheng; Wang, Zhiheng; Paul Segars, William; Yin, Fang-Fang

    2011-01-01

    Purpose: Four-dimensional computed tomography (4D-CT) has been widely used in radiation therapy to assess patient-specific breathing motion for determining individual safety margins. However, it has two major drawbacks: low soft-tissue contrast and an excessive imaging dose to the patient. This research aimed to develop a clinically feasible four-dimensional magnetic resonance imaging (4D-MRI) technique to overcome these limitations. Methods: The proposed 4D-MRI technique was achieved by continuously acquiring axial images throughout the breathing cycle using fast 2D cine-MR imaging, and then retrospectively sorting the images by respiratory phase. The key component of the technique was the use of body area (BA) of the axial MR images as an internal respiratory surrogate to extract the breathing signal. The validation of the BA surrogate was performed using 4D-CT images of 12 cancer patients by comparing the respiratory phases determined using the BA method to those determined clinically using the Real-time position management (RPM) system. The feasibility of the 4D-MRI technique was tested on a dynamic motion phantom, the 4D extended Cardiac Torso (XCAT) digital phantom, and two healthy human subjects. Results: Respiratory phases determined from the BA matched closely to those determined from the RPM: mean (±SD) difference in phase: −3.9% (±6.4%); mean (±SD) absolute difference in phase: 10.40% (±3.3%); mean (±SD) correlation coefficient: 0.93 (±0.04). In the motion phantom study, 4D-MRI clearly showed the sinusoidal motion of the phantom; image artifacts observed were minimal to none. Motion trajectories measured from 4D-MRI and 2D cine-MRI (used as a reference) matched excellently: the mean (±SD) absolute difference in motion amplitude: −0.3 (±0.5) mm. In the 4D-XCAT phantom study, the simulated “4D-MRI” images showed good consistency with the original 4D-XCAT phantom images. The motion trajectory of the hypothesized “tumor” matched

  19. SU-E-J-26: A Novel Technique for Markerless Self-Sorted 4D-CBCT Using Patient Motion Modeling: A Feasibility Study

    SciTech Connect

    Zhang, L; Zhang, Y; Harris, W; Yin, F; Ren, L

    2015-06-15

    Purpose: To develop an automatic markerless 4D-CBCT projection sorting technique by using a patient respiratory motion model extracted from the planning 4D-CT images. Methods: Each phase of onboard 4D-CBCT is considered as a deformation of one phase of the prior planning 4D-CT. The deformation field map (DFM) is represented as a linear combination of three major deformation patterns extracted from the planning 4D-CT using principle component analysis (PCA). The coefficients of the PCA deformation patterns are solved by matching the digitally reconstructed radiograph (DRR) of the deformed volume to the onboard projection acquired. The PCA coefficients are solved for each single projection, and are used for phase sorting. Projections at the peaks of the Z direction coefficient are sorted as phase 1 and other projections are assigned into 10 phase bins by dividing phases equally between peaks. The 4D digital extended-cardiac-torso (XCAT) phantom was used to evaluate the proposed technique. Three scenarios were simulated, with different tumor motion amplitude (3cm to 2cm), tumor spatial shift (8mm SI), and tumor body motion phase shift (2 phases) from prior to on-board images. Projections were simulated over 180 degree scan-angle for the 4D-XCAT. The percentage of accurately binned projections across entire dataset was calculated to represent the phase sorting accuracy. Results: With a changed tumor motion amplitude from 3cm to 2cm, markerless phase sorting accuracy was 100%. With a tumor phase shift of 2 phases w.r.t. body motion, the phase sorting accuracy was 100%. With a tumor spatial shift of 8mm in SI direction, phase sorting accuracy was 86.1%. Conclusion: The XCAT phantom simulation results demonstrated that it is feasible to use prior knowledge and motion modeling technique to achieve markerless 4D-CBCT phase sorting. National Institutes of Health Grant No. R01-CA184173 Varian Medical System.

  20. Relative charge transfer cross section from Rb (4d)

    NASA Astrophysics Data System (ADS)

    Shah, M. H.; Camp, H. A.; Trachy, M. L.; Fléchard, X.; Gearba, M. A.; Nguyen, H.; Brédy, R.; Lundeen, S. R.; Depaola, B. D.

    2005-08-01

    Relative charge transfer cross section measurements for the excited state Rb(4d) with 7keV Na+ is reported. The specific channels reported are Na++Rb(4d5/2)→Na(nl)+Rb+ , where the dominant transfer cross sections channels were nl=3d and 4s . Using a combination of a magneto-optical trap and recoil ion momentum spectroscopy (MOTRIMS methodology), the cross sections were measured relative to the previously studied Na++Rb(5s,5p) systems at the same collision energy.

  1. Relative charge transfer cross section from Rb(4d)

    SciTech Connect

    Shah, M.H.; Camp, H.A.; Trachy, M.L.; De Paola, B.D.; Flechard, X.; Gearba, M.A.; Nguyen, H.; Bredy, R.; Lundeen, S.R.

    2005-08-15

    Relative charge transfer cross section measurements for the excited state Rb(4d) with 7 keV Na{sup +} is reported. The specific channels reported are Na{sup +}+Rb(4d{sub 5/2}){yields}Na(nl)+Rb{sup +}, where the dominant transfer cross sections channels were nl=3d and 4s. Using a combination of a magneto-optical trap and recoil ion momentum spectroscopy (MOTRIMS methodology), the cross sections were measured relative to the previously studied Na{sup +}+Rb(5s,5p) systems at the same collision energy.

  2. The 4-D approach to visual control of autonomous systems

    NASA Technical Reports Server (NTRS)

    Dickmanns, Ernst D.

    1994-01-01

    Development of a 4-D approach to dynamic machine vision is described. Core elements of this method are spatio-temporal models oriented towards objects and laws of perspective projection in a foward mode. Integration of multi-sensory measurement data was achieved through spatio-temporal models as invariants for object recognition. Situation assessment and long term predictions were allowed through maintenance of a symbolic 4-D image of processes involving objects. Behavioral capabilities were easily realized by state feedback and feed-foward control.

  3. Emerging Applications of Abdominal 4D Flow MRI

    PubMed Central

    Roldán-Alzate, Alejandro; Francois, Christopher J.; Wieben, Oliver; Reeder, Scott B.

    2016-01-01

    OBJECTIVE Comprehensive assessment of abdominal hemodynamics is crucial for many clinical diagnoses but is challenged by a tremendous complexity of anatomy, normal physiology, and a wide variety of pathologic abnormalities. This article introduces 4D flow MRI as a powerful technique for noninvasive assessment of the hemodynamics of abdominal vascular territories. CONCLUSION Four-dimensional flow MRI provides clinicians with a more extensive and straightforward approach to evaluate disorders that affect blood flow in the abdomen. This review presents a series of clinical cases to illustrate the utility of 4D flow MRI in the comprehensive assessment of the abdominal circulation. PMID:27187681

  4. Development of a model of the coronary arterial tree for the 4D XCAT phantom

    NASA Astrophysics Data System (ADS)

    Fung, George S. K.; Segars, W. Paul; Gullberg, Grant T.; Tsui, Benjamin M. W.

    2011-09-01

    A detailed three-dimensional (3D) model of the coronary artery tree with cardiac motion has great potential for applications in a wide variety of medical imaging research areas. In this work, we first developed a computer-generated 3D model of the coronary arterial tree for the heart in the extended cardiac-torso (XCAT) phantom, thereby creating a realistic computer model of the human anatomy. The coronary arterial tree model was based on two datasets: (1) a gated cardiac dual-source computed tomography (CT) angiographic dataset obtained from a normal human subject and (2) statistical morphometric data of porcine hearts. The initial proximal segments of the vasculature and the anatomical details of the boundaries of the ventricles were defined by segmenting the CT data. An iterative rule-based generation method was developed and applied to extend the coronary arterial tree beyond the initial proximal segments. The algorithm was governed by three factors: (1) statistical morphometric measurements of the connectivity, lengths and diameters of the arterial segments; (2) avoidance forces from other vessel segments and the boundaries of the myocardium, and (3) optimality principles which minimize the drag force at the bifurcations of the generated tree. Using this algorithm, the 3D computational model of the largest six orders of the coronary arterial tree was generated, which spread across the myocardium of the left and right ventricles. The 3D coronary arterial tree model was then extended to 4D to simulate different cardiac phases by deforming the original 3D model according to the motion vector map of the 4D cardiac model of the XCAT phantom at the corresponding phases. As a result, a detailed and realistic 4D model of the coronary arterial tree was developed for the XCAT phantom by imposing constraints of anatomical and physiological characteristics of the coronary vasculature. This new 4D coronary artery tree model provides a unique simulation tool that can be

  5. Thoracic spine sports-related injuries.

    PubMed

    Menzer, Heather; Gill, G Keith; Paterson, Andrew

    2015-01-01

    Although sports-related injuries to the thoracic spine are relatively uncommon, they are among the most feared due to the potential for catastrophic neurologic injury. The increased biomechanical support of the thoracic spine makes injuries in this region particularly rare compared with the cervical and lumbar spine. As a result, thoracic spine injuries can be missed easily, difficult to diagnose, and problematic to treat. Recognition of mechanism and awareness of injury patterns help physicians determine a diagnosis and create an index of suspicion for unstable thoracic spine injuries. Aggressive full-contact sports receive the most attention for spinal injury; however several sports with repetitive loading of the spine can cause severe injuries, including rowing, gymnastics, and golf. The goal of this article was to provide an overview of the unique anatomic and biomechanical features of the thoracic spine and to discuss some of the more common thoracic injuries that can affect athletes. PMID:25574880

  6. Non-traumatic compression fractures of the thoracic spine following a seizure -- treatment by percutaneous kyphoplasty.

    PubMed

    Gnanalingham, K; Macanovic, M; Joshi, S; Afshar, F; Yeh, J

    2004-08-01

    A 26-year-old male presented with acute mid-thoracic back pain following a witnessed grand mal seizure. There was no trauma and the patient was on steroids for systemic lupus erythematosus. X-rays and CT scans of the thoracic spine revealed compression fractures at T5 and T6, with 50 % loss of vertebral height and kyphosis. He underwent percutaneous kyphoplasty of both vertebrae, with symptomatic improvement. Non-traumatic compression fractures of the thoracic spine following seizures are a rare injury. This may be related to the compressive forces exerted on the vertebral column by the contractions of the truncal muscles, during a seizure. These compression fractures are suitable for treatment by minimally invasive techniques, such as kyphoplasty.

  7. TEVAR: Endovascular Repair of the Thoracic Aorta

    PubMed Central

    Nation, David A.; Wang, Grace J.

    2015-01-01

    The development of thoracic endovascular aortic repair (TEVAR) has allowed a minimally invasive approach for management of an array of thoracic aortic pathologies. Initially developed specifically for exclusion of thoracic aortic aneurysms, TEVAR is now used as an alternative to open surgery for a variety of disease pathologies due to the lower morbidity of this approach. Advances in endograft technology continue to broaden the applications of this technique. PMID:26327745

  8. Super-resolution reconstruction for 4D computed tomography of the lung via the projections onto convex sets approach

    SciTech Connect

    Zhang, Yu E-mail: qianjinfeng08@gmail.com; Wu, Xiuxiu; Yang, Wei; Feng, Qianjin E-mail: qianjinfeng08@gmail.com; Chen, Wufan

    2014-11-01

    Purpose: The use of 4D computed tomography (4D-CT) of the lung is important in lung cancer radiotherapy for tumor localization and treatment planning. Sometimes, dense sampling is not acquired along the superior–inferior direction. This disadvantage results in an interslice thickness that is much greater than in-plane voxel resolutions. Isotropic resolution is necessary for multiplanar display, but the commonly used interpolation operation blurs images. This paper presents a super-resolution (SR) reconstruction method to enhance 4D-CT resolution. Methods: The authors assume that the low-resolution images of different phases at the same position can be regarded as input “frames” to reconstruct high-resolution images. The SR technique is used to recover high-resolution images. Specifically, the Demons deformable registration algorithm is used to estimate the motion field between different “frames.” Then, the projection onto convex sets approach is implemented to reconstruct high-resolution lung images. Results: The performance of the SR algorithm is evaluated using both simulated and real datasets. Their method can generate clearer lung images and enhance image structure compared with cubic spline interpolation and back projection (BP) method. Quantitative analysis shows that the proposed algorithm decreases the root mean square error by 40.8% relative to cubic spline interpolation and 10.2% versus BP. Conclusions: A new algorithm has been developed to improve the resolution of 4D-CT. The algorithm outperforms the cubic spline interpolation and BP approaches by producing images with markedly improved structural clarity and greatly reduced artifacts.

  9. 2,4-Dichlorophenoxyacetic acid (2,4-D)

    Integrated Risk Information System (IRIS)

    2,4 - Dichlorophenoxyacetic acid ( 2,4 - D ) ; CASRN 94 - 75 - 7 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Asses

  10. Enterococcus faecalis promotes osteoclastogenesis and semaphorin 4D expression.

    PubMed

    Wang, Shuai; Deng, Zuhui; Seneviratne, Chaminda J; Cheung, Gary S P; Jin, Lijian; Zhao, Baohong; Zhang, Chengfei

    2015-10-01

    Enterococcus faecalis is considered a major bacterial pathogen implicated in endodontic infections and contributes considerably to periapical periodontitis. This study aimed to investigate the potential mechanisms by which E. faecalis accounts for the bone destruction in periapical periodontitis in vitro. Osteoclast precursor RAW264.7 cells were treated with E. faecalis ATCC 29212 and a wild strain of E. faecalis derived clinically from an infected root canal. The results showed that, to some extent, E. faecalis induced the RAW264.7 cells to form tartrate-resistant acid phosphatase (TRAP)-positive multinucleated osteoclast-like cells. This pathogen markedly stimulated RAW264.7 cells to express semaphorin 4D (Sema4D), which inhibits bone formation. Once RAW264.7 cells were primed by low-dose receptor activator of nuclear factor-kappa B ligand (RANKL), E. faecalis could significantly increase the production of TRAP-positive multinucleated cells and up-regulate the expression of osteoclast-specific markers, including NFATc1, TRAP and cathepsin K. Both p38 and ERK1/2 MAPK signaling pathways were activated by E. faecalis in RANKL-primed RAW264.7 cells, and meanwhile the expression of Sema4D was highly increased. In conclusion, E. faecalis may greatly contribute to the bone resorption in periapical periodontitis by promoting RANKL-dependent osteoclastogenesis and expression of Sema4D through activation of p38 and ERK1/2 MAPK signaling pathways.

  11. 4D flow mri post-processing strategies for neuropathologies

    NASA Astrophysics Data System (ADS)

    Schrauben, Eric Mathew

    4D flow MRI allows for the measurement of a dynamic 3D velocity vector field. Blood flow velocities in large vascular territories can be qualitatively visualized with the added benefit of quantitative probing. Within cranial pathologies theorized to have vascular-based contributions or effects, 4D flow MRI provides a unique platform for comprehensive assessment of hemodynamic parameters. Targeted blood flow derived measurements, such as flow rate, pulsatility, retrograde flow, or wall shear stress may provide insight into the onset or characterization of more complex neuropathologies. Therefore, the thorough assessment of each parameter within the context of a given disease has important medical implications. Not surprisingly, the last decade has seen rapid growth in the use of 4D flow MRI. Data acquisition sequences are available to researchers on all major scanner platforms. However, the use has been limited mostly to small research trials. One major reason that has hindered the more widespread use and application in larger clinical trials is the complexity of the post-processing tasks and the lack of adequate tools for these tasks. Post-processing of 4D flow MRI must be semi-automated, fast, user-independent, robust, and reliably consistent for use in a clinical setting, within large patient studies, or across a multicenter trial. Development of proper post-processing methods coupled with systematic investigation in normal and patient populations pushes 4D flow MRI closer to clinical realization while elucidating potential underlying neuropathological origins. Within this framework, the work in this thesis assesses venous flow reproducibility and internal consistency in a healthy population. A preliminary analysis of venous flow parameters in healthy controls and multiple sclerosis patients is performed in a large study employing 4D flow MRI. These studies are performed in the context of the chronic cerebrospinal venous insufficiency hypothesis. Additionally, a

  12. 4D MR imaging using robust internal respiratory signal

    NASA Astrophysics Data System (ADS)

    Hui, CheukKai; Wen, Zhifei; Stemkens, Bjorn; Tijssen, R. H. N.; van den Berg, C. A. T.; Hwang, Ken-Pin; Beddar, Sam

    2016-05-01

    The purpose of this study is to investigate the feasibility of using internal respiratory (IR) surrogates to sort four-dimensional (4D) magnetic resonance (MR) images. The 4D MR images were constructed by acquiring fast 2D cine MR images sequentially, with each slice scanned for more than one breathing cycle. The 4D volume was then sorted retrospectively using the IR signal. In this study, we propose to use multiple low-frequency components in the Fourier space as well as the anterior body boundary as potential IR surrogates. From these potential IR surrogates, we used a clustering algorithm to identify those that best represented the respiratory pattern to derive the IR signal. A study with healthy volunteers was performed to assess the feasibility of the proposed IR signal. We compared this proposed IR signal with the respiratory signal obtained using respiratory bellows. Overall, 99% of the IR signals matched the bellows signals. The average difference between the end inspiration times in the IR signal and bellows signal was 0.18 s in this cohort of matching signals. For the acquired images corresponding to the other 1% of non-matching signal pairs, the respiratory motion shown in the images was coherent with the respiratory phases determined by the IR signal, but not the bellows signal. This suggested that the IR signal determined by the proposed method could potentially correct the faulty bellows signal. The sorted 4D images showed minimal mismatched artefacts and potential clinical applicability. The proposed IR signal therefore provides a feasible alternative to effectively sort MR images in 4D.

  13. Subacromial space in adult patients with thoracic hyperkyphosis and in healthy volunteers.

    PubMed

    Gumina, Stefano; Di Giorgio, Giantony; Postacchini, Franco; Postacchini, Roberto

    2008-02-01

    The assumption that subacromial space decreases in patients with thoracic hyperkyphosis arises from sporadic and personal observations. The purpose of this study was to compare width of subacromial space calculated on radiographs and CT scans of a high number of patients with thoracic hyperkyphosis that registered on exams of healthy volunteers. We measured the subacromial space, using Petersson's method, on radiographs of 47 patients with idiopathic or acquired thoracic hyperkyphosis and of 175 healthy shoulder volunteers. Both groups were further distinguished considering gender and age. Females with hyperkyphosis were also divided in two subgroups: those with a kyphotic curve of less (24 patients) or more (19 patients) than 50 degrees , respectively. Subacromial space of all patients and of 21 volunteers was also evaluated using CT. Acromio-humeral space was less wide in patients with hyperkyphosis with respect to coeval volunteers of the same gender; in females and in subjects older than 60. Subacromial width of females with hyperkyphosis whose curve was more than 50 degrees was significantly narrower (p<0.05) than that measured on radiograms or CT scans of females with a less severe spinal deformity. Decrease of subacromial space may be attributed to less posterior tilting of the scapula and to dyskinesis of the scapular movement. Scapular malposition causes an anomalous orientation of the acromion that may contribute to subacromial impingement. Patients with thoracic hyperkyphosis greater than 50 degrees had a subacromial space narrower than that measured in patients with a less severe kyphosis. This suggests that subacromial width is directly related to severity of thoracic kyphosis. Because hyperkyphosis of patients with osteoporotic vertebral fractures may worsen over the time, subacromial decompression could give only temporary shoulder pain relief. PMID:18320381

  14. Aiming at One-Stage Corrective Surgery for Extended Thoracic Aortic Dilatation

    PubMed Central

    Niinimaki, Eetu; Kajander, Henri; Paavonen, Timo; Sioris, Thanos; Mennander, Ari

    2014-01-01

    Definitive treatment of extended thoracic aortic dilatation is a major surgical challenge. Histopathology of resected thoracic aortic wall may reveal undiagnosed aortitis affecting outcome. We sought to investigate the benefit of thorough histopathology after one-stage corrective surgery for the treatment of extended thoracic aortic dilatation. Five patients underwent one-stage corrective surgery using the hybrid open arch repair by the frozen elephant trunk together with endovascular aortic grafting. A representative sample of the resected aortic arch was procured for histology. T- and B-lymphocytes, plasma cells, macrophages, and immunoglobulin G4 (IgG4) positivity were evaluated by immunohistochemistry. The mean preoperative maximum aortic diameter was 54 mm (range, 41–79 mm). The mean follow-up was 18 months (range, 1–24 months). As confirmed by computed tomography (CT) upon follow-up, complete thrombosis of the false lumen at the level of the frozen elephant trunk was achieved in all patients with dissection. One patient was operated due to atherosclerotic dilatation of the thoracic aorta, and postoperative CT showed successful exclusion of the atherosclerotic dilatation; this 75-year-old man was diagnosed with IgG4-positive aortitis and experienced unexpected blindness after surgery without evidence of emboli or long-term neurological impairment upon repeated brain CT. The hybrid open arch repair by the frozen elephant trunk and simultaneous endovascular repair is a feasible choice for one-stage surgery through sternotomy aiming at definitive treatment of extended thoracic aortic pathology. However, systematic evaluation of inflammation may reveal concealed aortitis affecting postoperative outcome and need for long-term surveillance. PMID:25075162

  15. Learning distance function for regression-based 4D pulmonary trunk model reconstruction estimated from sparse MRI data

    NASA Astrophysics Data System (ADS)

    Vitanovski, Dime; Tsymbal, Alexey; Ionasec, Razvan; Georgescu, Bogdan; Zhou, Shaohua K.; Hornegger, Joachim; Comaniciu, Dorin

    2011-03-01

    Congenital heart defect (CHD) is the most common birth defect and a frequent cause of death for children. Tetralogy of Fallot (ToF) is the most often occurring CHD which affects in particular the pulmonary valve and trunk. Emerging interventional methods enable percutaneous pulmonary valve implantation, which constitute an alternative to open heart surgery. While minimal invasive methods become common practice, imaging and non-invasive assessment tools become crucial components in the clinical setting. Cardiac computed tomography (CT) and cardiac magnetic resonance imaging (cMRI) are techniques with complementary properties and ability to acquire multiple non-invasive and accurate scans required for advance evaluation and therapy planning. In contrary to CT which covers the full 4D information over the cardiac cycle, cMRI often acquires partial information, for example only one 3D scan of the whole heart in the end-diastolic phase and two 2D planes (long and short axes) over the whole cardiac cycle. The data acquired in this way is called sparse cMRI. In this paper, we propose a regression-based approach for the reconstruction of the full 4D pulmonary trunk model from sparse MRI. The reconstruction approach is based on learning a distance function between the sparse MRI which needs to be completed and the 4D CT data with the full information used as the training set. The distance is based on the intrinsic Random Forest similarity which is learnt for the corresponding regression problem of predicting coordinates of unseen mesh points. Extensive experiments performed on 80 cardiac CT and MR sequences demonstrated the average speed of 10 seconds and accuracy of 0.1053mm mean absolute error for the proposed approach. Using the case retrieval workflow and local nearest neighbour regression with the learnt distance function appears to be competitive with respect to "black box" regression with immediate prediction of coordinates, while providing transparency to the

  16. Ansys Fluent versus Sim Vascular for 4-D patient-specific computational hemodynamics in renal arteries

    NASA Astrophysics Data System (ADS)

    Mumbaraddi, Avinash; Yu, Huidan (Whitney); Sawchuk, Alan; Dalsing, Michael

    2015-11-01

    The objective of this clinical-need driven research is to investigate the effect of renal artery stenosis (RAS) on the blood flow and wall shear stress in renal arteries through 4-D patient-specific computational hemodynamics (PSCH) and search for possible critical RASs that significantly alter the pressure gradient across the stenosis by manually varying the size of RAS from 50% to 95%. The identification of the critical RAS is important to understand the contribution of RAS to the overall renal resistance thus appropriate clinical therapy can be determined in order to reduce the hypertension. Clinical CT angiographic data together with Doppler Ultra sound images of an anonymous patient are used serving as the required inputs of the PSCH. To validate the PSCH, we use both Ansys Fluent and Sim Vascular and compare velocity, pressure, and wall-shear stress under identical conditions. Renal Imaging Technology Development Program (RITDP) Grant.

  17. Fast track endoscopic thoracic sympathicotomy.

    PubMed

    Duarte, João Bosco Vieira; Kux, Peter; Castro, Carlos H V; Cruvinel, Marcos G C; Costa, José R R

    2003-12-01

    The length of hospital stay is an important factor of cost and psychological discomfort in the treatment of hyperhidrosis by endoscopic thoracic sympathicotomy (ETS). Our experience enrolls 1587 patients operated on an outpatient basis in the last 10 years and seven months. This study aimed to confirm that ETS can be performed on an outpatient basis. Fifty-two consecutive patients (30 males and 22 females) were submitted to ETS under general anesthesia using a single lumen endotracheal tube, with lung collapse by intrapleural injection of CO(2). The sympathetic chain and the communicating rami were severed at different levels according to hyperhidrosis location. Patients were physical state American Society of Anesthesiologists 1 and 2. Age varied between 13 and 55 years (27.3 +/- 10.2 years). They were monitored with ECG, SPO2, NIBP, expired CO(2), sevoflurane analyzer, and airway pressure. Normal saline (40.0 +/- 2.7 ml/kg) was infused intravenously. The drugs used were propofol, alfentanil, rocuronium, ondansetron, dexamethasone, dipyrone, cetoprofene and sevoflurane. Anesthesia and post-operative data were analyzed. Post-operative thoracic X-rays were taken in 20 patients before discharge. Anesthesia lasted 67.2 +/- 20.8 minutes, and the surgical procedure took 46.3 +/- 20.9 minutes. The patients stayed 18.0 +/- 11.0 minutes in the post-anaesthetic care unit and were discharged from hospital after 150.3 +/- 43.1 minutes. The only abnormal post-operative event observed was insignificant residual carbothorax, found in 2 (10%) of the thoracic X-rays taken. In conclusion, this study confirmed that ETS can be performed safely on an outpatient basis. PMID:14673677

  18. Analgesia in thoracic surgery: review.

    PubMed

    De Cosmo, G; Aceto, P; Gualtieri, E; Congedo, E

    2009-06-01

    Post-thoracotomy pain is one of the most severe types of postoperative pain. It can last up to 2 months and can become chronic in 30% of patients. Pain relief after thoracic surgery is of particular significance, not only for ethical considerations but also for reduction of postoperative pulmonary and cardiac complications. Because of the difficulty in pain control, many approaches have been suggested, but a multimodal therapeutic strategy that provides a central or peripheral block associated with nonsteroidal anti-inflammatory (NSAID) and adjuvant drugs is now the cornerstone of treatment, offering the possibility of reducing opioid requirements and side effects. Thoracic epidural analgesia with local anesthetics and opioids is regarded as the gold standard treatment for post-thoracotomy pain management because it results in early extubation, better ventilatory mechanisms and gas exchange, decreased incidence of atelectasis, pneumonia and chronic postoperative pain. When epidural analgesia is contraindicated or cannot be performed, other regional techniques of analgesia can be used. An alternative method of providing adequate pain relief is a thoracic paravertebral block: continuous paravertebral infusion of local anesthetic via a catheter placed percutaneously or under direct vision during thoracotomy. This is effective in controlling postoperative pain and in preserving pulmonary function. Other techniques, such as intercostal and interpleural blocks, are rarely utilized, whereas a single shot of intrathecal injection of a hydrophilic opioid, such as morphine, appears to be effective. Cryoanalgesia, which is successful in the immediate postoperative period, has been abandoned for its brief duration and increased incidence of chronic pain. PMID:18953284

  19. [A review on thoracic ultrasound].

    PubMed

    Fernández-Bussy, Sebastián; Labarca, Gonzalo; Lanza, Mario; Folch, Erik; Majid, Adnan

    2016-07-01

    The use of thoracic ultrasound as a diagnostic tool in the emergency department, intensive care unit or in patients with pulmonary diseases is increasing steadily. It is used to guide percutaneous tracheostomies, to assess pleural effusions, to rule out pneumothorax, and to guide the placement of endovascular and pleural catheters. It is also useful in the assessment of patients with dyspnea. The aim of this review is to provide the practical and technical basics for the use of this diagnostic tool among internists and specialists in pulmonary diseases. PMID:27661554

  20. A penetrating dorsal thoracic injury that is lucky from every aspect: A case report

    PubMed Central

    İlhan, Mehmet; Gök, Ali Fuat Kaan; Öner, Gizem; Günay, Kayıhan; Ertekin, Cemalettin

    2016-01-01

    Introduction Penetrating thoracic trauma management represents a major problem for emergency department staff. In these cases, we reported a patient, who can be deemed very lucky, because of both the trauma mechanism and the provided first aid at scene. Presentation of case A 30-year-old man was transported to the emergency surgery outpatient clinic after being stabbed from his back. A knife entered thorax from the dorsal region paravertebrally between two scapulae. No vascular and thoracic injuries were detected in the CT. The knife was then pulled and removed, and pressure dressing was applied on the wound. He was discharged with full recovery on the second day of admission. Discussion Thoracic traumas may present as blunt or penetrating traumas. Trauma with penetrating dorsal thoracic injuries is usually in the form of stabbing, sharp penetrating object injuries, or firearm injuries. The aim of a successful trauma management is to determine whether a life-threatening condition exists. The general rules of penetrating trauma management are to avoid in-depth exploration for wound site assessment, to avoid removal of penetrating object without accurate diagnosis, and to keep in mind the possibility of intubation for airway security in every moment. Conclusion During the initial care of patients with penetrating trauma, the object should not be removed from its place. Our patient was lucky enough in that no thoracic pathology developed during the accident and he was not subjected to any secondary trauma during ambulance transport. PMID:27100954

  1. Shape-correlated deformation statistics for respiratory motion prediction in 4D lung

    NASA Astrophysics Data System (ADS)

    Liu, Xiaoxiao; Oguz, Ipek; Pizer, Stephen M.; Mageras, Gig S.

    2010-02-01

    4D image-guided radiation therapy (IGRT) for free-breathing lungs is challenging due to the complicated respiratory dynamics. Effective modeling of respiratory motion is crucial to account for the motion affects on the dose to tumors. We propose a shape-correlated statistical model on dense image deformations for patient-specic respiratory motion estimation in 4D lung IGRT. Using the shape deformations of the high-contrast lungs as the surrogate, the statistical model trained from the planning CTs can be used to predict the image deformation during delivery verication time, with the assumption that the respiratory motion at both times are similar for the same patient. Dense image deformation fields obtained by diffeomorphic image registrations characterize the respiratory motion within one breathing cycle. A point-based particle optimization algorithm is used to obtain the shape models of lungs with group-wise surface correspondences. Canonical correlation analysis (CCA) is adopted in training to maximize the linear correlation between the shape variations of the lungs and the corresponding dense image deformations. Both intra- and inter-session CT studies are carried out on a small group of lung cancer patients and evaluated in terms of the tumor location accuracies. The results suggest potential applications using the proposed method.

  2. Evolution of thoracic surgery in Canada

    PubMed Central

    Deslauriers, Jean; Griffith Pearson, F; Nelems, Bill

    2015-01-01

    BACKGROUND: Canada’s contributions toward the 21st century’s practice of thoracic surgery have been both unique and multilayered. Scattered throughout are tales of pioneers where none had gone before, where opportunities were greeted by creativity and where iconic figures followed one another. OBJECTIVE: To describe the numerous and important achievements of Canadian thoracic surgeons in the areas of surgery for pulmonary tuberculosis, thoracic oncology, airway surgery and lung transplantation. METHOD: Information was collected through reading of the numerous publications written by Canadian thoracic surgeons over the past 100 years, interviews with interested people from all thoracic surgery divisions across Canada and review of pertinent material form the archives of several Canadian hospitals and universities. RESULTS: Many of the developments occurred by chance. It was the early and specific focus on thoracic surgery, to the exclusion of cardiac and general surgery, that distinguishes the Canadian experience, a model that is now emerging everywhere. From lung transplantation in chimera twin calves to ex vivo organ preservation, from the removal of airways to tissue regeneration, and from intensive care research to complex science, Canadians have excelled in their commitment to research. Over the years, the influence of Canadian thoracic surgery on international practice has been significant. CONCLUSIONS: Canada spearheaded the development of thoracic surgery over the past 100 years to a greater degree than any other country. From research to education, from national infrastructures to the regionalization of local practices, it happened in Canada.

  3. Evaluation of dosimetric misrepresentations from 3D conventional planning of liver SBRT using 4D deformable dose integration.

    PubMed

    Yeo, Unjin A; Taylor, Michael L; Supple, Jeremy R; Siva, Shankar; Kron, Tomas; Pham, Daniel; Franich, Rick D

    2014-11-08

    The purpose of this study is to evaluate dosimetric errors in 3D conventional plan- ning of stereotactic body radiotherapy (SBRT) by using a 4D deformable image registration (DIR)-based dose-warping and integration technique. Respiratory- correlated 4D CT image sets with 10 phases were acquired for four consecutive patients with five liver tumors. Average intensity projection (AIP) images were used to generate 3D conventional plans of SBRT. Quasi-4D path-integrated dose accumulation was performed over all 10 phases using dose-warping techniques based on DIR. This result was compared to the conventional plan in order to evalu- ate the appropriateness of 3D (static) dose calculations. In addition, we consider whether organ dose metrics derived from contours defined on the average intensity projection (AIP), or on a reference phase, provide the better approximation of the 4D values. The impact of using fewer (< 10) phases was also explored. The AIP- based 3D planning approach overestimated doses to targets by 1.4% to 8.7% (mean 4.2%) and underestimated dose to normal liver by up to 8% (mean -5.5%; range -2.3% to -8.0%), compared to the 4D methodology. The homogeneity of the dose distribution was overestimated when using conventional 3D calculations by up to 24%. OAR doses estimated by 3D planning were, on average, within 10% of the 4D calculations; however, differences of up to 100% were observed. Four-dimensional dose calculation using 3 phases gave a reasonable approximation of that calculated from the full 10 phases for all patients, which is potentially useful from a workload perspective. 4D evaluation showed that conventional 3D planning on an AIP can significantly overestimate target dose (ITV and GTV+5mm), underestimate normal liver dose, and overestimate dose homogeneity. Implementing nonadaptive quasi- 4D dose calculation can highlight the potential limitation of 3D conventional SBRT planning and the resultant misrepresentations of dose in some regions

  4. Exome sequencing identifies PDE4D mutations in acrodysostosis.

    PubMed

    Lee, Hane; Graham, John M; Rimoin, David L; Lachman, Ralph S; Krejci, Pavel; Tompson, Stuart W; Nelson, Stanley F; Krakow, Deborah; Cohn, Daniel H

    2012-04-01

    Acrodysostosis is a dominantly-inherited, multisystem disorder characterized by skeletal, endocrine, and neurological abnormalities. To identify the molecular basis of acrodysostosis, we performed exome sequencing on five genetically independent cases. Three different missense mutations in PDE4D, which encodes cyclic AMP (cAMP)-specific phosphodiesterase 4D, were found to be heterozygous in three of the cases. Two of the mutations were demonstrated to have occurred de novo, providing strong genetic evidence of causation. Two additional cases were heterozygous for de novo missense mutations in PRKAR1A, which encodes the cAMP-dependent regulatory subunit of protein kinase A and which has been recently reported to be the cause of a form of acrodysostosis resistant to multiple hormones. These findings demonstrate that acrodysostosis is genetically heterogeneous and underscore the exquisite sensitivity of many tissues to alterations in cAMP homeostasis. PMID:22464252

  5. Intelligent Vehicle Systems: A 4D/RCS Approach

    SciTech Connect

    Madhavan, Raj

    2007-04-01

    This book presents new research on autonomous mobility capabilities and shows how technological advances can be anticipated in the coming two decades. An in-depth description is presented on the theoretical foundations and engineering approaches that enable these capabilities. Chapter 1 provides a brief introduction to the 4D/RCS reference model architecture and design methodology that has proven successful in guiding the development of autonomous mobility systems. Chapters 2 through 7 provide more detailed descriptions of research that has been conducted and algorithms that have been developed to implement the various aspects of the 4D/RCS reference model architecture and design methodology. Chapters 8 and 9 discuss applications, performance measures, and standards. Chapter 10 provides a history of Army and DARPA research in autonomous ground mobility. Chapter 11 provides a perspective on the potential future developments in autonomous mobility.

  6. 4D embryonic cardiography using gated optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Jenkins, M. W.; Rothenberg, F.; Roy, D.; Nikolski, V. P.; Hu, Z.; Watanabe, M.; Wilson, D. L.; Efimov, I. R.; Rollins, A. M.

    2006-01-01

    Simultaneous imaging of very early embryonic heart structure and function has technical limitations of spatial and temporal resolution. We have developed a gated technique using optical coherence tomography (OCT) that can rapidly image beating embryonic hearts in four-dimensions (4D), at high spatial resolution (10-15 μm), and with a depth penetration of 1.5 - 2.0 mm that is suitable for the study of early embryonic hearts. We acquired data from paced, excised, embryonic chicken and mouse hearts using gated sampling and employed image processing techniques to visualize the hearts in 4D and measure physiologic parameters such as cardiac volume, ejection fraction, and wall thickness. This technique is being developed to longitudinally investigate the physiology of intact embryonic hearts and events that lead to congenital heart defects.

  7. Impact of scanning parameters and breathing patterns on image quality and accuracy of tumor motion reconstruction in 4D CBCT: a phantom study.

    PubMed

    Lee, Soyoung; Yan, Guanghua; Lu, Bo; Kahler, Darren; Li, Jonathan G; Sanjiv, Samat S

    2015-01-01

    Four-dimensional, cone-beam CT (4D CBCT) substantially reduces respiration-induced motion blurring artifacts in three-dimension (3D) CBCT. However, the image quality of 4D CBCT is significantly degraded which may affect its accuracy in localizing a mobile tumor for high-precision, image-guided radiation therapy (IGRT). The purpose of this study was to investigate the impact of scanning parameters hereinafter collectively referred to as scanning sequence) and breathing patterns on the image quality and the accuracy of computed tumor trajectory for a commercial 4D CBCT system, in preparation for its clinical implementation. We simulated a series of periodic and aperiodic sinusoidal breathing patterns with a respiratory motion phantom. The aperiodic pattern was created by varying the period or amplitude of individual sinusoidal breathing cycles. 4D CBCT scans of the phantom were acquired with a manufacturer-supplied scanning sequence (4D-S-slow) and two in-house modified scanning sequences (4D-M-slow and 4D-M-fast). While 4D-S-slow used small field of view (FOV), partial rotation (200°), and no imaging filter, 4D-M-slow and 4D-M-fast used medium FOV, full rotation, and the F1 filter. The scanning speed was doubled in 4D-M-fast (100°/min gantry rotation). The image quality of the 4D CBCT scans was evaluated using contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), and motion blurring ratio (MBR). The trajectory of the moving target was reconstructed by registering each phase of the 4D CBCT with a reference CT. The root-mean-squared-error (RMSE) analysis was used to quantify its accuracy. Significant decrease in CNR and SNR from 3D CBCT to 4D CBCT was observed. The 4D-S-slow and 4D-M-fast scans had comparable image quality, while the 4D-M-slow scans had better performance due to doubled projections. Both CNR and SNR decreased slightly as the breathing period increased, while no dependence on the amplitude was observed. The difference of both CNR and SNR

  8. 4D flow cardiovascular magnetic resonance consensus statement.

    PubMed

    Dyverfeldt, Petter; Bissell, Malenka; Barker, Alex J; Bolger, Ann F; Carlhäll, Carl-Johan; Ebbers, Tino; Francios, Christopher J; Frydrychowicz, Alex; Geiger, Julia; Giese, Daniel; Hope, Michael D; Kilner, Philip J; Kozerke, Sebastian; Myerson, Saul; Neubauer, Stefan; Wieben, Oliver; Markl, Michael

    2015-01-01

    Pulsatile blood flow through the cavities of the heart and great vessels is time-varying and multidirectional. Access to all regions, phases and directions of cardiovascular flows has formerly been limited. Four-dimensional (4D) flow cardiovascular magnetic resonance (CMR) has enabled more comprehensive access to such flows, with typical spatial resolution of 1.5×1.5×1.5 - 3×3×3 mm(3), typical temporal resolution of 30-40 ms, and acquisition times in the order of 5 to 25 min. This consensus paper is the work of physicists, physicians and biomedical engineers, active in the development and implementation of 4D Flow CMR, who have repeatedly met to share experience and ideas. The paper aims to assist understanding of acquisition and analysis methods, and their potential clinical applications with a focus on the heart and greater vessels. We describe that 4D Flow CMR can be clinically advantageous because placement of a single acquisition volume is straightforward and enables flow through any plane across it to be calculated retrospectively and with good accuracy. We also specify research and development goals that have yet to be satisfactorily achieved. Derived flow parameters, generally needing further development or validation for clinical use, include measurements of wall shear stress, pressure difference, turbulent kinetic energy, and intracardiac flow components. The dependence of measurement accuracy on acquisition parameters is considered, as are the uses of different visualization strategies for appropriate representation of time-varying multidirectional flow fields. Finally, we offer suggestions for more consistent, user-friendly implementation of 4D Flow CMR acquisition and data handling with a view to multicenter studies and more widespread adoption of the approach in routine clinical investigations. PMID:26257141

  9. Phosphodiesterase 4D gene polymorphisms in sudden sensorineural hearing loss.

    PubMed

    Chien, Chen-Yu; Tai, Shu-Yu; Wang, Ling-Feng; Hsi, Edward; Chang, Ning-Chia; Wang, Hsun-Mo; Wu, Ming-Tsang; Ho, Kuen-Yao

    2016-09-01

    The phosphodiesterase 4D (PDE4D) gene has been reported as a risk gene for ischemic stroke. The vascular factors are between the hypothesized etiologies of sudden sensorineural hearing loss (SSNHL), and this genetic effect might be attributed for its role in SSNHL. We hypothesized that genetic variants of the PDE4D gene are associated with susceptibility to SSNHL. We conducted a case-control study with 362 SSNHL cases and 209 controls. Three single nucleotide polymorphisms (SNPs) were selected. The genotypes were determined using TaqMan technology. Hardy-Weinberg equilibrium (HWE) was tested for each SNP, and genetic effects were evaluated according to three inheritance modes. We carried out sex-specific analysis to analyze the overall data. All three SNPs were in HWE. When subjects were stratified by sex, the genetic effect was only evident in females but not in males. The TT genotype of rs702553 exhibited an adjusted odds ratio (OR) of 3.83 (95 % confidence interval = 1.46-11.18) (p = 0.006) in female SSNHL. The TT genotype of SNP rs702553 was associated with female SSNHL under the recessive model (p = 0.004, OR 3.70). In multivariate logistic regression analysis, TT genotype of rs702553 was significantly associated with female SSNHL (p = 0.0043, OR 3.70). These results suggest that PDE4D gene polymorphisms influence the susceptibility for the development of SSNHL in the southern Taiwanese female population.

  10. Thoracic organ transplantation: laboratory methods.

    PubMed

    Patel, Jignesh K; Kobashigawa, Jon A

    2013-01-01

    Although great progress has been achieved in thoracic organ transplantation through the development of effective immunosuppression, there is still significant risk of rejection during the early post-transplant period, creating a need for routine monitoring for both acute antibody and cellular mediated rejection. The currently available multiplexed, microbead assays utilizing solubilized HLA antigens afford the capability of sensitive detection and identification of HLA and non-HLA specific antibodies. These assays are being used to assess the relative strength of donor specific antibodies; to permit performance of virtual crossmatches which can reduce the waiting time to transplantation; to monitor antibody levels during desensitization; and for heart transplants to monitor antibodies post-transplant. For cell mediated immune responses, the recent development of gene expression profiling has allowed noninvasive monitoring of heart transplant recipients yielding predictive values for acute cellular rejection. T cell immune monitoring in heart and lung transplant recipients has allowed individual tailoring of immunosuppression, particularly to minimize risk of infection. While the current antibody and cellular laboratory techniques have enhanced the ability to manage thoracic organ transplant recipients, future developments from improved understanding of microchimerism and graft tolerance may allow more refined allograft monitoring techniques. PMID:23775735

  11. Bilateral internal thoracic artery grafting

    PubMed Central

    2013-01-01

    The effectiveness of the left internal mammary artery graft to the anterior descending coronary artery as a surgical strategy has been shown to improve the survival rate and decrease the risk of adverse cardiac events in patients undergoing coronary bypass surgery. These clinical benefits appear to be related to the superior short and long-term patency rates of the internal thoracic artery graft. Although the advantages of using of both internal thoracic arteries (ITA) for bypass grafting have taken longer to prove, recent results from multiple data sets now support these findings. The major advantage of bilateral ITA grafting appears to be improved survival rate, while the disadvantages of complex ITA grafting include the increased complexity of operation, and an increased risk of wound complications. While these short-term disadvantages have been mitigated in contemporary surgical practice, they have not eliminated. Bilateral ITA grafting should be considered the procedure of choice for patients undergoing coronary bypass surgery that have a predicted survival rate of longer than ten years. PMID:23977627

  12. A 4D Hyperspherical Interpretation of q-Space

    PubMed Central

    Hosseinbor, A. Pasha; Chung, Moo K.; Wu, Yu-Chien; Bendlin, Barbara B.; Alexander, Andrew L.

    2015-01-01

    3D q-space can be viewed as the surface of a 4D hypersphere. In this paper, we seek to develop a 4D hyperspherical interpretation of q-space by projecting it onto a hypersphere and subsequently modeling the q-space signal via 4D hyperspherical harmonics (HSH). Using this orthonormal basis, we derive several well-established q-space indices and numerically estimate the diffusion orientation distribution function (dODF). We also derive the integral transform describing the relationship between the diffusion signal and propagator on a hypersphere. Most importantly, we will demonstrate that for hybrid diffusion imaging (HYDI) acquisitions low order linear expansion of the HSH basis is sufficient to characterize diffusion in neural tissue. In fact, the HSH basis achieves comparable signal and better dODF reconstructions than other well-established methods, such as Bessel Fourier orientation reconstruction (BFOR), using fewer fitting parameters. All in all, this work provides a new way of looking at q-space. PMID:25624043

  13. 4D-Flow validation, numerical and experimental framework

    NASA Astrophysics Data System (ADS)

    Sansom, Kurt; Liu, Haining; Canton, Gador; Aliseda, Alberto; Yuan, Chun

    2015-11-01

    This work presents a group of assessment metrics of new 4D MRI flow sequences, an imaging modality that allows for visualization of three-dimensional pulsatile flow in the cardiovascular anatomy through time-resolved three-dimensional blood velocity measurements from cardiac-cycle synchronized MRI acquisition. This is a promising tool for clinical assessment but lacks a robust validation framework. First, 4D-MRI flow in a subject's stenotic carotid bifurcation is compared with a patient-specific CFD model using two different boundary condition methods. Second, Particle Image Velocimetry in a patient-specific phantom is used as a benchmark to compare the 4D-MRI in vivo measurements and CFD simulations under the same conditions. Comparison of estimated and measureable flow parameters such as wall shear stress, fluctuating velocity rms, Lagrangian particle residence time, will be discussed, with justification for their biomechanics relevance and the insights they can provide on the pathophysiology of arterial disease: atherosclerosis and intimal hyperplasia. Lastly, the framework is applied to a new sequence to provide a quantitative assessment. A parametric analysis on the carotid bifurcation pulsatile flow conditions will be presented and an accuracy assessment provided.

  14. Assessment of Left Ventricular Function in Cardiac MSCT Imaging by a 4D Hierarchical Surface-Volume Matching Process

    PubMed Central

    Simon, Antoine; Boulmier, Dominique; Coatrieux, Jean-Louis; Le Breton, Hervé

    2006-01-01

    Multislice computed tomography (MSCT) scanners offer new perspectives for cardiac kinetics evaluation with 4D dynamic sequences of high contrast and spatiotemporal resolutions. A new method is proposed for cardiac motion extraction in multislice CT. Based on a 4D hierarchical surface-volume matching process, it provides the detection of the heart left cavities along the acquired sequence and the estimation of their 3D surface velocity fields. A Markov random field model is defined to find, according to topological descriptors, the best correspondences between a 3D mesh describing the left endocardium at one time and the 3D acquired volume at the following time. The global optimization of the correspondences is realized with a multiresolution process. Results obtained on simulated and real data show the capabilities to extract clinically relevant global and local motion parameters and highlight new perspectives in cardiac computed tomography imaging. PMID:23165027

  15. Dosimetric Quantities for Computed Tomography Examinations of Paediatric Patients on the Thoracic and Abdominal Regions

    SciTech Connect

    Flores-M, E.; Gamboa de Buen, I.; Buenfil, A. E.; Ruiz-Trejo, C.; Dies, P.

    2010-12-07

    Computed Tomography (CT) is a high dose X ray imaging procedure and its use has rapidly increased in the last two decades fueled by the development of helical CT. The aim of this study is to present values of the dosimetric quantities for CT paediatric examinations of thoracic and abdominal regions. The protocols studied were those of chest, lung-mediastine, chest-abdomen, pulmonary high resolution and mediastine-abdomen, which are the more common examinations performed at ''Hospital Infantil de Mexico Federico Gomez'' in the thoracic-abdominal region. The measurements were performed on a Siemens SOMATOM Sensation 16 CT Scanner and the equipment used was a CT pencil ionization chamber, connected to an electrometer. This system was calibrated for RQT9 CT beam quality. A PMMA head phantom with diameter of 16 cm and length of 15 cm was also used. The dosimetric quantities measured were the weighted air kerma index (C{sub w}), the volumetric dose index (C{sub vol}) and the CT air kerma-length product. It was found that the pulmonary high resolution examination presented the highest values for the C{sub w}(31.1 mGy) and C{sub vol}(11.1 mGy). The examination with the lowest values of these two quantities was the chest-abdomen protocol with 10.5 mGy for C{sub w} and 5.5 mGy for C{sub vol}. However, this protocol presented the highest value for P{sub KL,CT}(282.2 mGy cm) when considering the average clinical length of the examinations.

  16. Poster — Thur Eve — 71: A 4D Multimodal Lung Phantom for Regmentation Evaluation

    SciTech Connect

    Markel, D; Levesque, I R; El Naqa, I

    2014-08-15

    Segmentation and registration of medical imaging data are two processes that can be integrated (a process termed regmentation) to iteratively reinforce each other, potentially improving efficiency and overall accuracy. A significant challenge is presented when attempting to validate the joint process particularly with regards to minimizing geometric uncertainties associated with the ground truth while maintaining anatomical realism. This work demonstrates a 4D MRI, PET, and CT compatible tissue phantom with a known ground truth for evaluating registration and segmentation accuracy. The phantom consists of a preserved swine lung connected to an air pump via a PVC tube for inflation. Mock tumors were constructed from sea sponges contained within two vacuum-sealed compartments with catheters running into each one for injection of radiotracer solution. The phantom was scanned using a GE Discovery-ST PET/CT scanner and a 0.23T Phillips MRI, and resulted in anatomically realistic images. A bifurcation tracking algorithm was implemented to provide a ground truth for evaluating registration accuracy. This algorithm was validated using known deformations of up to 7.8 cm using a separate CT scan of a human thorax. Using the known deformation vectors to compare against, 76 bifurcation points were selected. The tracking accuracy was found to have maximum mean errors of −0.94, 0.79 and −0.57 voxels in the left-right, anterior-posterior and inferior-superior directions, respectively. A pneumatic control system is under development to match the respiratory profile of the lungs to a breathing trace from an individual patient.

  17. Ossification of thoracic ligamenta flava

    SciTech Connect

    Kudo, S.; Minoru, O.; Russell, W.J.

    1983-07-01

    Although ligamentum flavum ossification (LFO) often occurs in normal persons, there are no reports of its detection on lateral chest radiographs made during screening examinations. Review of 1,744 consecutive lateral chest radiographs identified LFO in 6.2% of males and 4.8% of females. LFO occurred mainly at the intervertebral segments from T9-T10 through T12-L1. Most prevalent was the hook-shaped LFO, protruding inferoirly from the inferior facets into the projections of the intervertabral foramina. Though LFO can cause severe neurologic symptoms, none of the affected persons in this study reported such symptoms. LFO was first visualized radiographically when the subjects were 20-40 years old, and it may be a physiologic condition. The LFO in these cases existed independent of thoracic posterior longitudinal ligament ossification, diffuse idiopathic skeletal hyperostosis, and degenerative osteoarthritis.

  18. [Thoracic nocardiosis - a clinical report].

    PubMed

    Vale, Artur; Guerra, Miguel; Martins, Daniel; Lameiras, Angelina; Miranda, José; Vouga, Luís

    2014-01-01

    Nocardia genus microorganisms are ubiquitous, Gram positive aerobic bacterias, responsible for disease mainly in immunocompromised hosts, with cellular immune response commitment. Inhalation is the main form of transmition and pulmonary disease is the most frequent presentation. Dissemination may occur by contiguity and also via hematogenous. The clinical and imaging presentation is not specific, and diagnosis is obtained after identification of Nocardia bacteria in biological samples. Since there are no reliable studies that indicate the best therapeutic option, treatment should be individualized and based on antimicrobial susceptibility testing. Surgical drainage should also be considered in all patients. The authors present a clinical case of a patient with thoracic nocardiosis, and make a short literature review on the theme.

  19. Thoracic Extraosseous Epidural Cavernous Hemangioma

    PubMed Central

    Asil, Kiyasettin; Ceylan, Davut; Erdem, Sahin

    2015-01-01

    Cavernous hemangiomas were first reported in 1929 by Globus and Doshay, and are defined as benign vascular structures developed between the neural tissues occurring in the central nervous system, consisting of a dilated vascular bed. Cavernous hemangiomas comprise nearly 5-12% of all spinal vascular malformations; however, existence in the epidural space without bone involvement is rare. Only 4% of all cavernous hemangiomas (0.22/1.000.000) are purely epidural cavernous hemangiomas. In this case report, we removed a hemorrhagic thoracic mass presenting with progressive neurological deficits in a 55-year-old male patient. We found this case to be appropriate for presentation due to the rare occurrence of this type of cavernous hemangioma. PMID:25674348

  20. Head CT scan

    MedlinePlus

    Brain CT; Cranial CT; CT scan - skull; CT scan - head; CT scan - orbits; CT scan - sinuses; Computed tomography - cranial; CAT scan - brain ... conditions: Birth (congenital) defect of the head or brain Brain infection Brain tumor Buildup of fluid inside ...

  1. [Noninvasive radiodiagnosis of aneurysms of the thoracic aorta].

    PubMed

    Todua, F I; Petsko, A R; Arablinskiĭ, A V; Kazanchian, P O; Nikitaev, N S; Sultanaliev, T A

    1990-05-01

    The paper is concerned with analysis of the results of X-ray investigation of 45 patients with aneurysms of the distal part of the arch and descending part of the thoracic aorta. Errors were made in 16 of 35 patients (35.6%) before admittance to hospital. X-ray investigation helped to establish correct diagnosis of aneurysm of the aorta in 42 of 45 patients (93.3%) on the basis of the detection of intense additional shadow formation in left pulmonary field, inseparable from the aortic shadow. The use of a new method of ultrasound diagnosis--duplex scanning--made it possible to establish the presence of aneurysm and to determine its sizes as well as to visualize the relation of the left subclavicular artery to aneurysm in 17 of 21 patients. CT-semiotics of aneurysms of the descending part of the thoracic aorta consisted in its dilatation over 3.5 cm, wall calcification, thrombosis of the cavity and change of the adjacent structures. Basing on the analysis of these signs correct diagnosis was established in 34 of 35 examinees (97.1%).

  2. Localization of 4D gravity on pure geometrical thick branes

    SciTech Connect

    Barbosa-Cendejas, Nandinii; Herrera-Aguilar, Alfredo

    2006-04-15

    We consider the generation of thick brane configurations in a pure geometric Weyl integrable 5D spacetime which constitutes a non-Riemannian generalization of Kaluza-Klein (KK) theory. In this framework, we show how 4D gravity can be localized on a scalar thick brane which does not necessarily respect reflection symmetry, generalizing in this way several previous models based on the Randall-Sundrum (RS) system and avoiding both, the restriction to orbifold geometries and the introduction of the branes in the action by hand. We first obtain a thick brane solution that preserves 4D Poincare invariance and breaks Z{sub 2}-symmetry along the extra dimension which, indeed, can be either compact or extended, and supplements brane solutions previously found by other authors. In the noncompact case, this field configuration represents a thick brane with positive energy density centered at y=c{sub 2}, whereas pairs of thick branes arise in the compact case. Remarkably, the Weylian scalar curvature is nonsingular along the fifth dimension in the noncompact case, in contraposition to the RS thin brane system. We also recast the wave equations of the transverse traceless modes of the linear fluctuations of the classical background into a Schroedinger's equation form with a volcano potential of finite bottom in both the compact and the extended cases. We solve Schroedinger equation for the massless zero mode m{sup 2}=0 and obtain a single bound wave function which represents a stable 4D graviton. We also get a continuum gapless spectrum of KK states with m{sup 2}>0 that are suppressed at y=c{sub 2} and turn asymptotically into plane waves.

  3. Non-spherical particle generation from 4D optofluidic fabrication.

    PubMed

    Paulsen, Kevin S; Chung, Aram J

    2016-08-01

    Particles with non-spherical shapes can exhibit properties which are not available from spherical shaped particles. Complex shaped particles can provide unique benefits for areas such as drug delivery, tissue engineering, structural materials, and self-assembly building blocks. Current methods of creating complex shaped particles such as 3D printing, photolithography, and imprint lithography are limited by either slow speeds, shape limitations, or expensive processes. Previously, we presented a novel microfluidic flow lithography fabrication scheme combined with fluid inertia called optofluidic fabrication for the creation of complex shaped three-dimensional (3D) particles. This process was able to address the aforementioned limits and overcome two-dimensional shape limitations faced by traditional flow lithography methods; however, all of the created 3D particle shapes displayed top-down symmetry. Here, by introducing the time dimension into our existing optofluidic fabrication process, we break this top-down symmetry, generating fully asymmetric 3D particles where we termed the process: four-dimensional (4D) optofluidic fabrication. This 4D optofluidic fabrication is comprised of three sequential procedures. First, density mismatched precursor fluids flow past pillars within fluidic channels to manipulate the flow cross sections via fluid inertia. Next, the time dimension is incorporated by stopping the flow and allowing the denser fluids to settle by gravity to create asymmetric flow cross sections. Finally, the fluids are exposed to patterned ultraviolet (UV) light in order to polymerize fully asymmetric 3D-shaped particles. By varying inertial flow shaping, gravity-induced flow shaping, and UV light patterns, 4D optofluidic fabrication can create an infinite set of complex shaped asymmetric particles. PMID:27092661

  4. Non-spherical particle generation from 4D optofluidic fabrication.

    PubMed

    Paulsen, Kevin S; Chung, Aram J

    2016-08-01

    Particles with non-spherical shapes can exhibit properties which are not available from spherical shaped particles. Complex shaped particles can provide unique benefits for areas such as drug delivery, tissue engineering, structural materials, and self-assembly building blocks. Current methods of creating complex shaped particles such as 3D printing, photolithography, and imprint lithography are limited by either slow speeds, shape limitations, or expensive processes. Previously, we presented a novel microfluidic flow lithography fabrication scheme combined with fluid inertia called optofluidic fabrication for the creation of complex shaped three-dimensional (3D) particles. This process was able to address the aforementioned limits and overcome two-dimensional shape limitations faced by traditional flow lithography methods; however, all of the created 3D particle shapes displayed top-down symmetry. Here, by introducing the time dimension into our existing optofluidic fabrication process, we break this top-down symmetry, generating fully asymmetric 3D particles where we termed the process: four-dimensional (4D) optofluidic fabrication. This 4D optofluidic fabrication is comprised of three sequential procedures. First, density mismatched precursor fluids flow past pillars within fluidic channels to manipulate the flow cross sections via fluid inertia. Next, the time dimension is incorporated by stopping the flow and allowing the denser fluids to settle by gravity to create asymmetric flow cross sections. Finally, the fluids are exposed to patterned ultraviolet (UV) light in order to polymerize fully asymmetric 3D-shaped particles. By varying inertial flow shaping, gravity-induced flow shaping, and UV light patterns, 4D optofluidic fabrication can create an infinite set of complex shaped asymmetric particles.

  5. [Thoracic actinomycosis versus bronchial cancer].

    PubMed

    Brombacher-Frey, I; Wöckel, W; Kreusser, T

    1992-01-01

    We report on 4 thoracic actinomycoses; in three of these four cases a bronchial carcinoma was suspected, and in case No. 2 this carcinoma had been considered to be in a very advanced and inoperable stage. A man of 51 years of age was in a generally run-down condition. He also noticed that his sputum was tinged with blood. The x-ray film showed a large space-occupying growth at the right lung hilus. Repeated perbronchial biopsies of the focus did not yield any diagnosis. Actinomycosis was identified histologically only in the tissue samples obtained via thoracotomy. After a three-month penicillin course the hilar shadow receded. A 61-year old male patient was transferred to our Pneumological Hospital, being strongly suspected of suffering from an extensive bronchial carcinoma, and having multiple intrathoracic space-occupying growths as well as pleural effusions, a pericardial effusion, and an infiltration of the left thoracic wall with fistula formation; however, histological examination of skin biopsies revealed that he was suffering from actinomycosis. Antibiotic therapy cured him completely in a six-month course. In a man of 32 years of age who had been indulging for many years in a severe abuse of nicotin, we suspected a central bronchial carcinoma on the basis of his x-ray, but histology of the tissue taken from the space-occupying growth via diagnostic thoracotomy revealed that this patient, too, suffered from actinomycosis. Complete recession occurred after several months of antibiotic treatment. A woman of 82 years had been an inpatient for several months in another hospital because of relapsing pleuropneumonias on the right side. She was transferred to us as an outpatient after a renewed relapse. We conducted a transcutaneous fine-needle biopsy of the right indurating pleural effusion. A few actinomyces filaments were seen on histological examination of the purulent exudate. Hence, actinomycosis was confirmed. After antibiotic therapy the finding receded

  6. Founding Gravitation in 4D Euclidean Space-Time Geometry

    SciTech Connect

    Winkler, Franz-Guenter

    2010-11-24

    The Euclidean interpretation of special relativity which has been suggested by the author is a formulation of special relativity in ordinary 4D Euclidean space-time geometry. The natural and geometrically intuitive generalization of this view involves variations of the speed of light (depending on location and direction) and a Euclidean principle of general covariance. In this article, a gravitation model by Jan Broekaert, which implements a view of relativity theory in the spirit of Lorentz and Poincare, is reconstructed and shown to fulfill the principles of the Euclidean approach after an appropriate reinterpretation.

  7. CMT4D (NDRG1 mutation): genotype-phenotype correlations.

    PubMed

    Ricard, Emilie; Mathis, Stéphane; Magdelaine, Corinne; Delisle, Marie-Bernadette; Magy, Laurent; Funalot, Benoît; Vallat, Jean-Michel

    2013-09-01

    Charcot-Marie-Tooth (CMT) disease is a heterogeneous condition with a large number of clinical, electrophysiological and pathological phenotypes. More than 40 genes are involved. We report a child of gypsy origin with an autosomal recessive demyelinating phenotype. Clinical data, familial history, and electrophysiological studies were in favor of a CMT4 sub-type. The characteristic N-Myc downstream-regulated gene 1 (NDRG1) mutation responsible for this CMT4D phenotype was confirmed: p.R148X. The exact molecular function of the NDRG1 protein has yet to be elucidated.

  8. Multicolor 4D Fluorescence Microscopy using Ultrathin Bessel Light Sheets.

    PubMed

    Zhao, Teng; Lau, Sze Cheung; Wang, Ying; Su, Yumian; Wang, Hao; Cheng, Aifang; Herrup, Karl; Ip, Nancy Y; Du, Shengwang; Loy, M M T

    2016-01-01

    We demonstrate a simple and efficient method for producing ultrathin Bessel ('non-diffracting') light sheets of any color using a line-shaped beam and an annulus filter. With this robust and cost-effective technology, we obtained two-color, 3D images of biological samples with lateral/axial resolution of 250 nm/400 nm, and high-speed, 4D volume imaging of 20 μm sized live sample at 1 Hz temporal resolution. PMID:27189786

  9. Oblique sounding using the DPS-4D stations in Europe

    NASA Astrophysics Data System (ADS)

    Mosna, Zbysek; Kouba, Daniel; Koucka Knizova, Petra; Arikan, Feza; Arikan, Orhan; Gok, Gokhan; Rejfek, Lubos

    2016-07-01

    The DPS-4D Digisondes are capable of detection of echoes from neighbouring European stations. Currently, a campaign with high-temporal resolution of 5 min is being run. Further, ionograms from regular vertical sounding with 15 min resolution provide us with oblique reflections together with vertical reflections. We analyzed profiles of electron concentration and basic ionospheric parameters derived from the ionograms. We compared results derived from reflections from the ionosphere above the stations (vertical sounding) with information derived from oblique reflections between the stations. This study is supported by the Joint TUBITAK 114E092 and AS CR 14/001 projects.

  10. Lagrangian constraints and renormalization of 4D gravity

    NASA Astrophysics Data System (ADS)

    Park, I. Y.

    2015-04-01

    It has been proposed in [21] that 4D Einstein gravity becomes effectively reduced to 3D after solving the Lagrangian analogues of the Hamiltonian and momentum constraints of the Hamiltonian quantization. The analysis in [21] was carried out at the classical/operator level. We review the proposal and make a transition to the path integral account. We then set the stage for explicitly carrying out the two-loop renormalization procedure of the resulting 3D action. We also address a potentially subtle issue in the gravity context concerning whether renormalizability does not depend on the background around which the original action is expanded.

  11. Multicolor 4D Fluorescence Microscopy using Ultrathin Bessel Light Sheets

    PubMed Central

    Zhao, Teng; Lau, Sze Cheung; Wang, Ying; Su, Yumian; Wang, Hao; Cheng, Aifang; Herrup, Karl; Ip, Nancy Y.; Du, Shengwang; Loy, M. M. T.

    2016-01-01

    We demonstrate a simple and efficient method for producing ultrathin Bessel (‘non-diffracting’) light sheets of any color using a line-shaped beam and an annulus filter. With this robust and cost-effective technology, we obtained two-color, 3D images of biological samples with lateral/axial resolution of 250 nm/400 nm, and high-speed, 4D volume imaging of 20 μm sized live sample at 1 Hz temporal resolution. PMID:27189786

  12. All the supersymmetric configurations of N=4, d=4 supergravity

    NASA Astrophysics Data System (ADS)

    Bellorín, Jorge; Ortín, Tomás

    2005-10-01

    All the supersymmetric configurations of pure, ungauged, N=4, d=4 supergravity are classified in a formalism that keeps manifest the S and T dualities of the theory. We also find simple equations that need to be satisfied by the configurations to be classical solutions of the theory. While the solutions associated to null Killing vectors were essentially classified by Tod (a classification that we refine), we find new configurations and solutions associated to timelike Killing vectors that do not satisfy Tod's rigidity hypothesis (hence, they have a nontrivial U(1) connection) and whose supersymmetry projector is associated to 1-dimensional objects (strings), although they have a trivial axion field.

  13. Thoracic aorta aneurysm successfully operated on during pregnancy

    PubMed Central

    Biskupski, Andrzej; Kuligowska, Ewelina; Listewnik, Mariusz; Brykczyński, Mirosław

    2014-01-01

    We present the case of an asymptomatic 26-year-old female patient with a huge thoracic aneurysm discovered at a routine echo screening. The patient had previously been operated on for coarctation of the aorta in childhood and also had diagnosed bicuspid aortic valve. The operation was carried out in extracorporeal circulation at the 22nd week of gestation without any complications. A few months later in the 38th week of pregnancy a baby girl was delivered by cesarean section with an Apgar score of 10. The patient is scheduled for implantation of a stent graft to the descending aorta, because the CT of the chest done a few months after delivery confirmed presence of a significant aneurysm located just below the left subclavian artery. PMID:26336442

  14. A Case Of Atypical Presentation of Thoracic Osteomyelitis & Paraspinal Abscess

    PubMed Central

    Acharya, Utkarsh

    2008-01-01

    Here presented is a case involving a 44-year-old man with a chief complaint of sharp lateral right-sided rib pain with notable radiation to the anterior portion of the thorax and minor radiation around the lateral back. The etiology of the pain and radiculopathy, which was initially attributed to a right-sided rib fracture, was later accurately credited to a paraspinal abscess discovered on a lateral X-ray of the thoracic spine. Subsequently, studies including Magnetic Resonance Imaging (MRI), Computed Tomography (CT), and bone scan all confirmed the diagnosis of a paraspinal abscess between the right lobe and its neighboring T9 and T10 vertebrae. The mass was biopsied and methicillin sensitive Staphylococcus aureus was isolated. Appropriate surgical and medical intervention was possible due to the early diagnosis of the abscess. PMID:19148317

  15. Thoracic outlet syndrome secondary to a mid-clavicle malunion.

    PubMed

    Beliaev, Andrei M; Fougere, Christopher

    2015-01-01

    A 22-year-old man presented with a painful 'clunking' sensation in the right mid-clavicle, and pain and dysaesthesia along the medial aspect of his right arm and hand. Three months earlier, he had been involved in a vehicle accident and sustained a right clavicle fracture. He had a large step off of the right clavicle with a medialisation of the right shoulder. At 90° abduction in external rotation of both shoulders he developed pain, paraesthesia and disappearance of the right radial artery pulsation. CT of the right shoulder in the neutral position demonstrated the clavicle-to-first rib distance of 5.5 mm, MRI showed the clavicular bone callus had a mass effect with effacement of anterior fat adjacent to the brachial plexus cords. He was diagnosed with thoracic outlet syndrome and underwent a corrective right clavicle osteotomy with the use of an AcuMed superior clavicle plate. PMID:26045517

  16. Thoracic ranula: an extremely rare case.

    PubMed

    Pang, Claudine Elizabeth; Lee, Tee Sin; Pang, Kenny Peter; Pang, Yoke Teen

    2005-03-01

    We present the first case of a thoracic ranula which originated from the left submandibular area extending into the subcutaneous tissue planes of the anterior chest wall. The patient had a history of surgery for a previous benign left salivary gland cyst, and presented with an enlarging mass in the anterior chest wall. This was a recurrence of a ranula, with an extension into the anterior thoracic wall. The thoracic ranula was excised, together with ipsilateral sublingual and submandibular glands, via a transcervical approach. No recurrence was detected over a 3-year post-operative follow up.

  17. Evaluation of intrinsic respiratory signal determination methods for 4D CBCT adapted for mice

    SciTech Connect

    Martin, Rachael; Pan, Tinsu; Rubinstein, Ashley; Court, Laurence; Ahmad, Moiz

    2015-01-15

    Purpose: 4D CT imaging in mice is important in a variety of areas including studies of lung function and tumor motion. A necessary step in 4D imaging is obtaining a respiratory signal, which can be done through an external system or intrinsically through the projection images. A number of methods have been developed that can successfully determine the respiratory signal from cone-beam projection images of humans, however only a few have been utilized in a preclinical setting and most of these rely on step-and-shoot style imaging. The purpose of this work is to assess and make adaptions of several successful methods developed for humans for an image-guided preclinical radiation therapy system. Methods: Respiratory signals were determined from the projection images of free-breathing mice scanned on the X-RAD system using four methods: the so-called Amsterdam shroud method, a method based on the phase of the Fourier transform, a pixel intensity method, and a center of mass method. The Amsterdam shroud method was modified so the sharp inspiration peaks associated with anesthetized mouse breathing could be detected. Respiratory signals were used to sort projections into phase bins and 4D images were reconstructed. Error and standard deviation in the assignment of phase bins for the four methods compared to a manual method considered to be ground truth were calculated for a range of region of interest (ROI) sizes. Qualitative comparisons were additionally made between the 4D images obtained using each of the methods and the manual method. Results: 4D images were successfully created for all mice with each of the respiratory signal extraction methods. Only minimal qualitative differences were noted between each of the methods and the manual method. The average error (and standard deviation) in phase bin assignment was 0.24 ± 0.08 (0.49 ± 0.11) phase bins for the Fourier transform method, 0.09 ± 0.03 (0.31 ± 0.08) phase bins for the modified Amsterdam shroud method, 0

  18. Endograft Collapse After Endovascular Treatment for Thoracic Aortic Disease

    SciTech Connect

    Bandorski, Dirk Brueck, Martin; Guenther, Hans-Ulrich; Manke, Christoph

    2010-06-15

    Endovascular treatment is an established therapy for thoracic aortic disease. Collapse of the endograft is a potentially fatal complication. We reviewed 16 patients with a thoracic endograft between 2001 and 2006. Medical records of the treated patients were studied. Data collected include age, gender, diagnosis, indication for endoluminal treatment, type of endograft, and time of follow up. All patients (n = 16; mean age, 61 years; range, 21-82 years) underwent computed tomography (CT) for location of the lesion and planning of the intervention. Time of follow-up with CT scan ranged from 1 to 61 months. Indications for endovascular treatment were degenerative aneurysm (n = 7; 44%), aortic dissection (n = 2; 12%), perforated aortic ulcer (n = 4; 25%), and traumatic aortic injury (n = 3; 19%). Three patients suffered from a collapse of the endograft (one patient distal, two patients proximal) between 3 and 8 days after endovascular treatment. These patients were younger (mean age, 37 {+-} 25 years vs. 67 {+-} 16 years; P < 0.05) and showed more oversizing (proximal, 36 {+-} 19.8% vs. 29 {+-} 20.7% [P > 0.05]; distal, 45 {+-} 23.5% vs. 38 {+-} 21.7% [P > 0.05]). Proximal collapse was corrected by placing a bare stent. In conclusion, risk factors for stent-graft collapse are a small lumen of the aorta and a small radius of the aortic arch curvature (young patients), as well as oversizing, which is an important risk factor and is described for different types of endografts and protheses (Gore TAG and Cook Zenith). Dilatation of the collapsed stent-graft is not sufficient. Following therapy implantation of a second stent or surgery is necessary in patients with a proximal endograft collapse. Distal endograft collapse can possibly be treated conservatively under close follow-up.

  19. Functional organization of the human 4D Nucleome

    PubMed Central

    Chen, Haiming; Chen, Jie; Muir, Lindsey A.; Ronquist, Scott; Meixner, Walter; Ljungman, Mats; Ried, Thomas; Smale, Stephen; Rajapakse, Indika

    2015-01-01

    The 4D organization of the interphase nucleus, or the 4D Nucleome (4DN), reflects a dynamical interaction between 3D genome structure and function and its relationship to phenotype. We present initial analyses of the human 4DN, capturing genome-wide structure using chromosome conformation capture and 3D imaging, and function using RNA-sequencing. We introduce a quantitative index that measures underlying topological stability of a genomic region. Our results show that structural features of genomic regions correlate with function with surprising persistence over time. Furthermore, constructing genome-wide gene-level contact maps aided in identifying gene pairs with high potential for coregulation and colocalization in a manner consistent with expression via transcription factories. We additionally use 2D phase planes to visualize patterns in 4DN data. Finally, we evaluated gene pairs within a circadian gene module using 3D imaging, and found periodicity in the movement of clock circadian regulator and period circadian clock 2 relative to each other that followed a circadian rhythm and entrained with their expression. PMID:26080430

  20. Atlas construction for dynamic (4D) PET using diffeomorphic transformations.

    PubMed

    Bieth, Marie; Lombaert, Hervé; Reader, Andrew J; Siddiqi, Kaleem

    2013-01-01

    A novel dynamic (4D) PET to PET image registration procedure is proposed and applied to multiple PET scans acquired with the high resolution research tomograph (HRRT), the highest resolution human brain PET scanner available in the world. By extending the recent diffeomorphic log-demons (DLD) method and applying it to multiple dynamic [11C]raclopride scans from the HRRT, an important step towards construction of a PET atlas of unprecedented quality for [11C]raclopride imaging of the human brain has been achieved. Accounting for the temporal dimension in PET data improves registration accuracy when compared to registration of 3D to 3D time-averaged PET images. The DLD approach was chosen for its ease in providing both an intensity and shape template, through iterative sequential pair-wise registrations with fast convergence. The proposed method is applicable to any PET radiotracer, providing 4D atlases with useful applications in high accuracy PET data simulations and automated PET image analysis. PMID:24579121

  1. 488-4D ASH LANDFILL CLOSURE CAP HELP MODELING

    SciTech Connect

    Phifer, M.

    2014-11-17

    At the request of Area Completion Projects (ACP) in support of the 488-4D Landfill closure, the Savannah River National Laboratory (SRNL) has performed Hydrologic Evaluation of Landfill Performance (HELP) modeling of the planned 488-4D Ash Landfill closure cap to ensure that the South Carolina Department of Health and Environmental Control (SCDHEC) limit of no more than 12 inches of head on top of the barrier layer (saturated hydraulic conductivity of no more than 1.0E-05 cm/s) in association with a 25-year, 24-hour storm event is not projected to be exceeded. Based upon Weber 1998 a 25-year, 24-hour storm event at the Savannah River Site (SRS) is 6.1 inches. The results of the HELP modeling indicate that the greatest peak daily head on top of the barrier layer (i.e. geosynthetic clay liner (GCL) or high density polyethylene (HDPE) geomembrane) for any of the runs made was 0.079 inches associated with a peak daily precipitation of 6.16 inches. This is well below the SCDHEC limit of 12 inches.

  2. 4D Dynamic Required Navigation Performance Final Report

    NASA Technical Reports Server (NTRS)

    Finkelsztein, Daniel M.; Sturdy, James L.; Alaverdi, Omeed; Hochwarth, Joachim K.

    2011-01-01

    New advanced four dimensional trajectory (4DT) procedures under consideration for the Next Generation Air Transportation System (NextGen) require an aircraft to precisely navigate relative to a moving reference such as another aircraft. Examples are Self-Separation for enroute operations and Interval Management for in-trail and merging operations. The current construct of Required Navigation Performance (RNP), defined for fixed-reference-frame navigation, is not sufficiently specified to be applicable to defining performance levels of such air-to-air procedures. An extension of RNP to air-to-air navigation would enable these advanced procedures to be implemented with a specified level of performance. The objective of this research effort was to propose new 4D Dynamic RNP constructs that account for the dynamic spatial and temporal nature of Interval Management and Self-Separation, develop mathematical models of the Dynamic RNP constructs, "Required Self-Separation Performance" and "Required Interval Management Performance," and to analyze the performance characteristics of these air-to-air procedures using the newly developed models. This final report summarizes the activities led by Raytheon, in collaboration with GE Aviation and SAIC, and presents the results from this research effort to expand the RNP concept to a dynamic 4D frame of reference.

  3. Thoracic Duct Embolization with Lipiodol for Chylothorax due to Thoracic Endovascular Aortic Repair with Debranching Procedure

    PubMed Central

    Lee, Kwang Hyoung; Jung, Jae Seung; Cho, Sung Bum; Lee, Seung Hun; Kim, Hee Jung; Son, Ho Sung

    2015-01-01

    Chylothorax is a rare postoperative complication of a thoracic surgical procedure. Here, we report a case of chylothorax after thoracic endovascular aortic repair with debranching for the distal arch aneurysm of the aorta. First, the patient was treated by a medical method (nil per os, fat-free diet, and octreotide), but this method failed. The patient strongly refused surgical treatment. Therefore, we tried to occlude the thoracic duct by lymphangiography Lipiodol, and this line of treatment was successful. PMID:25705604

  4. Thoracic and abdominal blastomycosis in a horse.

    PubMed

    Toribio, R E; Kohn, C W; Lawrence, A E; Hardy, J; Hutt, J A

    1999-05-01

    A 5-year-old Quarter Horse mare was examined because of lethargy, fever, and weight loss of 1 month's duration. Thoracic auscultation revealed decreased lung sounds cranioventrally. Thoracic ultrasonography revealed bilateral anechoic areas with hyperechoic strands, consistent with pleural effusion and fibrin tags. A large amount of free fluid was evident during abdominal ultrasonography. Abnormalities included anemia, hyperproteinemia, hyperglobulinemia, hyperfibrinogenemia, and hypoalbuminemia. Thoracic radiography revealed alveolar infiltrates in the cranial and caudoventral lung fields. A cavitary mass, consistent with an abscess, could be seen caudodorsal to the crura of the diaphragm. Ultrasonographic evaluation of this area revealed a hypoechoic mass with septations. Bilateral thoracocentesis was performed. Bacterial culture of the pleural fluid did not yield growth, but Blastomyces dermatitidis was isolated from pleural fluid, abdominal fluid, and an aspirate of the abscess. The mare was euthanatized, and a diagnosis of thoracic and abdominal blastomycosis was confirmed at necropsy. PMID:10319179

  5. 4D Light Field Imaging System Using Programmable Aperture

    NASA Technical Reports Server (NTRS)

    Bae, Youngsam

    2012-01-01

    Complete depth information can be extracted from analyzing all angles of light rays emanated from a source. However, this angular information is lost in a typical 2D imaging system. In order to record this information, a standard stereo imaging system uses two cameras to obtain information from two view angles. Sometimes, more cameras are used to obtain information from more angles. However, a 4D light field imaging technique can achieve this multiple-camera effect through a single-lens camera. Two methods are available for this: one using a microlens array, and the other using a moving aperture. The moving-aperture method can obtain more complete stereo information. The existing literature suggests a modified liquid crystal panel [LC (liquid crystal) panel, similar to ones commonly used in the display industry] to achieve a moving aperture. However, LC panels cannot withstand harsh environments and are not qualified for spaceflight. In this regard, different hardware is proposed for the moving aperture. A digital micromirror device (DMD) will replace the liquid crystal. This will be qualified for harsh environments for the 4D light field imaging. This will enable an imager to record near-complete stereo information. The approach to building a proof-ofconcept is using existing, or slightly modified, off-the-shelf components. An SLR (single-lens reflex) lens system, which typically has a large aperture for fast imaging, will be modified. The lens system will be arranged so that DMD can be integrated. The shape of aperture will be programmed for single-viewpoint imaging, multiple-viewpoint imaging, and coded aperture imaging. The novelty lies in using a DMD instead of a LC panel to move the apertures for 4D light field imaging. The DMD uses reflecting mirrors, so any light transmission lost (which would be expected from the LC panel) will be minimal. Also, the MEMS-based DMD can withstand higher temperature and pressure fluctuation than a LC panel can. Robotics need

  6. Semaphorin 4D Contributes to Rheumatoid Arthritis by Inducing Inflammatory Cytokine Production: Pathogenic and Therapeutic Implications

    PubMed Central

    Yoshida, Yuji; Kang, Sujin; Ebina, Kousuke; Shi, Kenrin; Nojima, Satoshi; Kimura, Tetsuya; Ito, Daisuke; Morimoto, Keiko; Nishide, Masayuki; Hosokawa, Takashi; Hirano, Toru; Shima, Yoshihito; Narazaki, Masashi; Tsuboi, Hideki; Saeki, Yukihiko; Tomita, Tetsuya; Tanaka, Toshio; Kumanogoh, Atsushi

    2015-01-01

    Objective Semaphorin 4D (Sema4D)/CD100 has pleiotropic roles in immune activation, angiogenesis, bone metabolism, and neural development. We undertook this study to investigate the role of Sema4D in rheumatoid arthritis (RA). Methods Soluble Sema4D (sSema4D) levels in serum and synovial fluid were analyzed by enzyme‐linked immunosorbent assay. Cell surface expression and transcripts of Sema4D were analyzed in peripheral blood cells from RA patients, and immunohistochemical staining of Sema4D was performed in RA synovium. Generation of sSema4D was evaluated in an ADAMTS‐4–treated monocytic cell line (THP‐1 cells). The efficacy of anti‐Sema4D antibody was evaluated in mice with collagen‐induced arthritis (CIA). Results Levels of sSema4D were elevated in both serum and synovial fluid from RA patients, and disease activity markers were correlated with serum sSema4D levels. Sema4D‐expressing cells also accumulated in RA synovium. Cell surface levels of Sema4D on CD3+ and CD14+ cells from RA patients were reduced, although levels of Sema4D transcripts were unchanged. In addition, ADAMTS‐4 cleaved cell surface Sema4D to generate sSema4D in THP‐1 cells. Soluble Sema4D induced tumor necrosis factor α (TNFα) and interleukin‐6 (IL‐6) production from CD14+ monocytes. IL‐6 and TNFα induced ADAMTS‐4 expression in synovial cells. Treatment with an anti‐Sema4D antibody suppressed arthritis and reduced proinflammatory cytokine production in CIA. Conclusion A positive feedback loop involving sSema4D/IL‐6 and TNFα/ADAMTS‐4 may contribute to the pathogenesis of RA. The inhibition of arthritis by anti‐Sema4D antibody suggests that Sema4D represents a potential therapeutic target for RA. PMID:25707877

  7. Clinical innovations in Philippine thoracic surgery

    PubMed Central

    2016-01-01

    Thoracic surgery in the Philippines followed the development of thoracic surgery in the United States and Europe. With better understanding of the physiology of the open chest and refinements in thoracic anesthetic and surgical approaches, Filipino surgeons began performing thoracoplasties, then lung resections for pulmonary tuberculosis and later for lung cancer in specialty hospitals dealing with pulmonary diseases—first at the Quezon Institute (QI) and presently at the Lung Center of the Philippines although some university and private hospitals made occasional forays into the chest. Esophageal surgery began its early attempts during the post-World War II era at the Philippine General Hospital (PGH), a university hospital affiliated with the University of the Philippines. With the introduction of minimally invasive thoracic surgical approaches, Filipino thoracic surgeons have managed to keep up with their Asian counterparts although the problems of financial reimbursement typical of a developing country remain. The need for creative innovative approaches of a focused multidisciplinary team will advance the boundaries of thoracic surgery in the Philippines.

  8. Clinical innovations in Philippine thoracic surgery.

    PubMed

    Danguilan, Jose Luis J

    2016-08-01

    Thoracic surgery in the Philippines followed the development of thoracic surgery in the United States and Europe. With better understanding of the physiology of the open chest and refinements in thoracic anesthetic and surgical approaches, Filipino surgeons began performing thoracoplasties, then lung resections for pulmonary tuberculosis and later for lung cancer in specialty hospitals dealing with pulmonary diseases-first at the Quezon Institute (QI) and presently at the Lung Center of the Philippines although some university and private hospitals made occasional forays into the chest. Esophageal surgery began its early attempts during the post-World War II era at the Philippine General Hospital (PGH), a university hospital affiliated with the University of the Philippines. With the introduction of minimally invasive thoracic surgical approaches, Filipino thoracic surgeons have managed to keep up with their Asian counterparts although the problems of financial reimbursement typical of a developing country remain. The need for creative innovative approaches of a focused multidisciplinary team will advance the boundaries of thoracic surgery in the Philippines. PMID:27651936

  9. Clinical innovations in Philippine thoracic surgery.

    PubMed

    Danguilan, Jose Luis J

    2016-08-01

    Thoracic surgery in the Philippines followed the development of thoracic surgery in the United States and Europe. With better understanding of the physiology of the open chest and refinements in thoracic anesthetic and surgical approaches, Filipino surgeons began performing thoracoplasties, then lung resections for pulmonary tuberculosis and later for lung cancer in specialty hospitals dealing with pulmonary diseases-first at the Quezon Institute (QI) and presently at the Lung Center of the Philippines although some university and private hospitals made occasional forays into the chest. Esophageal surgery began its early attempts during the post-World War II era at the Philippine General Hospital (PGH), a university hospital affiliated with the University of the Philippines. With the introduction of minimally invasive thoracic surgical approaches, Filipino thoracic surgeons have managed to keep up with their Asian counterparts although the problems of financial reimbursement typical of a developing country remain. The need for creative innovative approaches of a focused multidisciplinary team will advance the boundaries of thoracic surgery in the Philippines.

  10. Clinical innovations in Philippine thoracic surgery

    PubMed Central

    2016-01-01

    Thoracic surgery in the Philippines followed the development of thoracic surgery in the United States and Europe. With better understanding of the physiology of the open chest and refinements in thoracic anesthetic and surgical approaches, Filipino surgeons began performing thoracoplasties, then lung resections for pulmonary tuberculosis and later for lung cancer in specialty hospitals dealing with pulmonary diseases—first at the Quezon Institute (QI) and presently at the Lung Center of the Philippines although some university and private hospitals made occasional forays into the chest. Esophageal surgery began its early attempts during the post-World War II era at the Philippine General Hospital (PGH), a university hospital affiliated with the University of the Philippines. With the introduction of minimally invasive thoracic surgical approaches, Filipino thoracic surgeons have managed to keep up with their Asian counterparts although the problems of financial reimbursement typical of a developing country remain. The need for creative innovative approaches of a focused multidisciplinary team will advance the boundaries of thoracic surgery in the Philippines. PMID:27651936

  11. Biomechanics of DNA structures visualized by 4D electron microscopy

    PubMed Central

    Lorenz, Ulrich J.; Zewail, Ahmed H.

    2013-01-01

    We present a technique for in situ visualization of the biomechanics of DNA structural networks using 4D electron microscopy. Vibrational oscillations of the DNA structure are excited mechanically through a short burst of substrate vibrations triggered by a laser pulse. Subsequently, the motion is probed with electron pulses to observe the impulse response of the specimen in space and time. From the frequency and amplitude of the observed oscillations, we determine the normal modes and eigenfrequencies of the structures involved. Moreover, by selective “nano-cutting” at a given point in the network, it was possible to obtain Young’s modulus, and hence the stiffness, of the DNA filament at that position. This experimental approach enables nanoscale mechanics studies of macromolecules and should find applications in other domains of biological networks such as origamis. PMID:23382239

  12. Myocardial motion and function assessment using 4D images

    NASA Astrophysics Data System (ADS)

    Shi, Peng-Cheng; Robinson, Glynn P.; Duncan, James S.

    1994-09-01

    This paper describes efforts aimed at more objectively and accurately quantifying the local, regional and global function of the left ventricle (LV) of the heart from 4D image data. Using our shape-based image analysis methods, point-wise myocardial motion vector fields between successive image frames through the entire cardiac cycle will be computed. Quantitative LV motion, thickening, and strain measurements will then be established from the point correspondence maps. In the paper, we will also briefly describe an in vivo experimental model which uses implanted imaging-opaque markers to validate the results of our image analysis methods. Finally, initial experimental results using image sequences from two different modalities will be presented.

  13. 4D GPR Experiments--Towards the Virtual Lysimeter

    NASA Astrophysics Data System (ADS)

    Grasmueck, M.; Viggiano, D. A.; Day-Lewis, F. D.; Drasdis, J. B.; Kruse, S. E.; Or, D.

    2006-05-01

    In-situ monitoring of infiltration, water flow and retention in the vadose zone currently rely primarily on invasive methods, which irreversibly disturb original soil structure and alter its hydrologic behavior in the vicinity of the measurement. For example, use of lysimeters requires extraction and repacking of soil samples, and time- domain reflectometry (TDR) requires insertion of probes into the soil profile. This study investigates the use of repeated high-density 3D ground penetrating radar surveys (also known as 4D GPR) as a non-invasive alternative for detailed visualization and quantification of water flow in the vadose zone. Evaluation of the 4D GPR method was based on a series of controlled point-source water injection experiments into undisturbed beach sand deposits at Crandon Park in Miami, Florida. The goal of the GPR surveys was to image the shape and evolution of a wet-bulb as it propagates from the injection points (~0.5 m) towards the water table at 2.2 m depth. The experimental design was guided by predictive modeling using Hydrus 2D and finite-difference GPR waveform codes. Input parameters for the modeling were derived from hydrologic and electromagnetic characterization of representative sand samples. Guided by modeling results, we injected 30 to 40 liters of tap water through plastic-cased boreholes with slotted bottom sections (0.1 m) located 0.4 to 0.6 m below the surface. During and after injection, an area of 25 m2 was surveyed every 20 minutes using 250 and 500 MHz antennas with a grid spacing of 0.05 x 0.025 m. A total of 20 3D GPR surveys were completed over 3 infiltration sites. To confirm wet-bulb shapes measured by GPR, we injected 2 liters of "brilliant blue" dye (~100 mg/l) along with a saline water tracer towards the end of one experiment. After completion of GPR scanning, a trench was excavated to examine the distribution of the saltwater and dye using TDR and visual inspection, respectively. Preliminary analysis of the 4D GPR

  14. Chaos in a 4D dissipative nonlinear fermionic model

    NASA Astrophysics Data System (ADS)

    Aydogmus, Fatma

    2015-12-01

    Gursey Model is the only possible 4D conformally invariant pure fermionic model with a nonlinear self-coupled spinor term. It has been assumed to be similar to the Heisenberg's nonlinear generalization of Dirac's equation, as a possible basis for a unitary description of elementary particles. Gursey Model admits particle-like solutions for the derived classical field equations and these solutions are instantonic in character. In this paper, the dynamical nature of damped and forced Gursey Nonlinear Differential Equations System (GNDES) are studied in order to get more information on spinor type instantons. Bifurcation and chaos in the system are observed by constructing the bifurcation diagrams and Poincaré sections. Lyapunov exponent and power spectrum graphs of GNDES are also constructed to characterize the chaotic behavior.

  15. Parallel Wavefront Analysis for a 4D Interferometer

    NASA Technical Reports Server (NTRS)

    Rao, Shanti R.

    2011-01-01

    This software provides a programming interface for automating data collection with a PhaseCam interferometer from 4D Technology, and distributing the image-processing algorithm across a cluster of general-purpose computers. Multiple instances of 4Sight (4D Technology s proprietary software) run on a networked cluster of computers. Each connects to a single server (the controller) and waits for instructions. The controller directs the interferometer to several images, then assigns each image to a different computer for processing. When the image processing is finished, the server directs one of the computers to collate and combine the processed images, saving the resulting measurement in a file on a disk. The available software captures approximately 100 images and analyzes them immediately. This software separates the capture and analysis processes, so that analysis can be done at a different time and faster by running the algorithm in parallel across several processors. The PhaseCam family of interferometers can measure an optical system in milliseconds, but it takes many seconds to process the data so that it is usable. In characterizing an adaptive optics system, like the next generation of astronomical observatories, thousands of measurements are required, and the processing time quickly becomes excessive. A programming interface distributes data processing for a PhaseCam interferometer across a Windows computing cluster. A scriptable controller program coordinates data acquisition from the interferometer, storage on networked hard disks, and parallel processing. Idle time of the interferometer is minimized. This architecture is implemented in Python and JavaScript, and may be altered to fit a customer s needs.

  16. CT and PET-CT of a dog with multiple pulmonary adenocarcinoma.

    PubMed

    Kim, Jisun; Kwon, Seong Young; Cena, Rohani; Park, Seungjo; Oh, Juyeon; Oui, Heejin; Cho, Kyoung-Oh; Min, Jung-Joon; Choi, Jihye

    2014-04-01

    A 10-year-old, intact female Yorkshire terrier had multiple pulmonary nodules on thoracic radiography and ultrasonography with no lesions elsewhere. Computed tomography (CT) and positron emission tomography and computed tomography (PET-CT) using 18F-fluorodeoxyglucose (FDG) were performed to identify metastasis and undetected primary tumors. On CT examination, pulmonary nodules had a hypoattenuating center with thin peripheral enhancement, suggesting ischemic or necrotizing lesion. In PET-CT at 47 min after intravenous injection of 11.1 MBq/kg of FDG, the maximum standardized uptake value of each pulmonary nodule was about from 3.8 to 6.4. There were no abnormal lesions except for four pulmonary nodules on the CT and PET-CT. Primary lung tumor was tentatively diagnosed, and palliative therapy using 2 mg/kg tramadol and 2.2 mg/kg carprofen twice per day was applied. After the dog's euthanasia due to deteriorated clinical signs and poor prognosis, undifferentiated pulmonary adenocarcinoma was diagnosed through histopathologic and immunochemistry examination. To the best of the authors' knowledge, this is the first study of CT and PET-CT features of canine pulmonary adenocarcinoma. In this case, multiple pulmonary adenocarcinoma could be determined on the basis of FDG PET-CT through screening the obvious distant metastasis and/or lymph node invasions and excluding unknown primary tumors.

  17. Complications in CT-guided Procedures: Do We Really Need Postinterventional CT Control Scans?

    SciTech Connect

    Nattenmüller, Johanna Filsinger, Matthias Bryant, Mark Stiller, Wolfram Radeleff, Boris Grenacher, Lars Kauczor, Hans-Ullrich Hosch, Waldemar

    2013-06-19

    PurposeThe aim of this study is twofold: to determine the complication rate in computed tomography (CT)-guided biopsies and drainages, and to evaluate the value of postinterventional CT control scans.MethodsRetrospective analysis of 1,067 CT-guided diagnostic biopsies (n = 476) and therapeutic drainages (n = 591) in thoracic (n = 37), abdominal (n = 866), and musculoskeletal (ms) (n = 164) locations. Severity of any complication was categorized as minor or major. To assess the need for postinterventional CT control scans, it was determined whether complications were detected clinically, on peri-procedural scans or on postinterventional scans only.ResultsThe complication rate was 2.5 % in all procedures (n = 27), 4.4 % in diagnostic punctures, and 1.0 % in drainages; 13.5 % in thoracic, 2.0 % in abdominal, and 3.0 % in musculoskeletal procedures. There was only 1 major complication (0.1 %). Pneumothorax (n = 14) was most frequent, followed by bleeding (n = 9), paresthesia (n = 2), material damage (n = 1), and bone fissure (n = 1). Postinterventional control acquisitions were performed in 65.7 % (701 of 1,067). Six complications were solely detectable in postinterventional control acquisitions (3 retroperitoneal bleeds, 3 pneumothoraces); all other complications were clinically detectable (n = 4) and/or visible in peri-interventional controls (n = 21).ConclusionComplications in CT-guided interventions are rare. Of these, thoracic interventions had the highest rate, while pneumothoraces and bleeding were most frequent. Most complications can be detected clinically or peri-interventionally. To reduce the radiation dose, postinterventional CT controls should not be performed routinely and should be restricted to complicated or retroperitoneal interventions only.

  18. Simulation of four-dimensional CT images from deformable registration between inhale and exhale breath-hold CT scans

    SciTech Connect

    Sarrut, David; Boldea, Vlad; Miguet, Serge; Ginestet, Chantal

    2006-03-15

    Purpose: We propose to simulate an artificial four-dimensional (4-D) CT image of the thorax during breathing. It is performed by deformable registration of two CT scans acquired at inhale and exhale breath-hold. Materials and methods: Breath-hold images were acquired with the ABC (Active Breathing Coordinator) system. Dense deformable registrations were performed. The method was a minimization of the sum of squared differences (SSD) using an approximated second-order gradient. Gaussian and linear-elastic vector field regularizations were compared. A new preprocessing step, called a priori lung density modification (APLDM), was proposed to take into account lung density changes due to inspiration. It consisted of modulating the lung densities in one image according to the densities in the other, in order to make them comparable. Simulated 4-D images were then built by vector field interpolation and image resampling of the two initial CT images. A variation in the lung density was taken into account to generate intermediate artificial CT images. The Jacobian of the deformation was used to compute voxel values in Hounsfield units. The accuracy of the deformable registration was assessed by the spatial correspondence of anatomic landmarks located by experts. Results: APLDM produced statistically significantly better results than the reference method (registration without APLDM preprocessing). The mean (and standard deviation) of distances between automatically found landmark positions and landmarks set by experts were 2.7(1.1) mm with APLDM, and 6.3(3.8) mm without. Interexpert variability was 2.3(1.2) mm. The differences between Gaussian and linear elastic regularizations were not statistically significant. In the second experiment using 4-D images, the mean difference between automatic and manual landmark positions for intermediate CT images was 2.6(2.0) mm. Conclusion: The generation of 4-D CT images by deformable registration of inhale and exhale CT images is

  19. Cytomegalovirus Immunoglobulin After Thoracic Transplantation

    PubMed Central

    Grossi, Paolo; Mohacsi, Paul; Szabolcs, Zoltán; Potena, Luciano

    2016-01-01

    Abstract Cytomegalovirus (CMV) is a highly complex pathogen which, despite modern prophylactic regimens, continues to affect a high proportion of thoracic organ transplant recipients. The symptomatic manifestations of CMV infection are compounded by adverse indirect effects induced by the multiple immunomodulatory actions of CMV. These include a higher risk of acute rejection, cardiac allograft vasculopathy after heart transplantation, and potentially bronchiolitis obliterans syndrome in lung transplant recipients, with a greater propensity for opportunistic secondary infections. Prophylaxis for CMV using antiviral agents (typically oral valganciclovir or intravenous ganciclovir) is now almost universal, at least in high-risk transplants (D+/R−). Even with extended prophylactic regimens, however, challenges remain. The CMV events can still occur despite antiviral prophylaxis, including late-onset infection or recurrent disease, and patients with ganciclovir-resistant CMV infection or who are intolerant to antiviral therapy require alternative strategies. The CMV immunoglobulin (CMVIG) and antiviral agents have complementary modes of action. High-titer CMVIG preparations provide passive CMV-specific immunity but also exert complex immunomodulatory properties which augment the antiviral effect of antiviral agents and offer the potential to suppress the indirect effects of CMV infection. This supplement discusses the available data concerning the immunological and clinical effects of CMVIG after heart or lung transplantation. PMID:26900989

  20. Staged treatment of thoracic and lumbar spinal tuberculosis with flow injection abscess.

    PubMed

    Zeng, Hao; Zhang, Yupeng; Shen, Xiongjie; Luo, Chengke; Xu, Zhengquan; Liu, Zheng; Liu, Xiangyang; Wang, Xiyang

    2015-01-01

    The study was to investigate the feasibility and effectiveness of posterior-only approach combining with puncture drainage under CT-guide in staged treatment of thoracic and lumbar spinal tuberculosis with flow injection abscess. We retrospectively analyzed 15 patients (came from 72 cases with thoracic and lumbar spinal tuberculosis) with flow injection abscesses underwent surgery from January 2007 to February 2009, and evaluated the American Spinal Injury Association (ASIA) scoring system of nerve function, erythrocyte sedimentation rate (ESR), C-reactive protein (CRP), abscess absorption time and the Oswestry Disability Index (ODI), preoperatively and postoperatively. 15 patients were followed up for 13-37 months, no recurrence of tuberculosis, no fixation loosening and neurologic symptoms aggravated. The flow injection abscesses are absorbed within 3-6 months postoperative operation. In final follow-up, ESR went down to 5.2±2.1 mm/h from preoperative 79.6±14.8 mm/h, CRP decreased from preoperative 49.3±7.5 mg/L to 1.8±0.7 mg/L, ODI changed from 75.13±20.15 to 16.72±8.62, all of them changed significantly (P<0.05). In conclusions, one-stage posterior debridement, interbody fusion, pedicle screw fixation and two-stage CT-guided interventional therapy were safe and effective in treatment of the thoracic and lumbar spinal tuberculosis with flow injection abscess. PMID:26770442

  1. Staged treatment of thoracic and lumbar spinal tuberculosis with flow injection abscess

    PubMed Central

    Zeng, Hao; Zhang, Yupeng; Shen, Xiongjie; Luo, Chengke; Xu, Zhengquan; Liu, Zheng; Liu, Xiangyang; Wang, Xiyang

    2015-01-01

    The study was to investigate the feasibility and effectiveness of posterior-only approach combining with puncture drainage under CT-guide in staged treatment of thoracic and lumbar spinal tuberculosis with flow injection abscess. We retrospectively analyzed 15 patients (came from 72 cases with thoracic and lumbar spinal tuberculosis) with flow injection abscesses underwent surgery from January 2007 to February 2009, and evaluated the American Spinal Injury Association (ASIA) scoring system of nerve function, erythrocyte sedimentation rate (ESR), C-reactive protein (CRP), abscess absorption time and the Oswestry Disability Index (ODI), preoperatively and postoperatively. 15 patients were followed up for 13-37 months, no recurrence of tuberculosis, no fixation loosening and neurologic symptoms aggravated. The flow injection abscesses are absorbed within 3-6 months postoperative operation. In final follow-up, ESR went down to 5.2±2.1 mm/h from preoperative 79.6±14.8 mm/h, CRP decreased from preoperative 49.3±7.5 mg/L to 1.8±0.7 mg/L, ODI changed from 75.13±20.15 to 16.72±8.62, all of them changed significantly (P<0.05). In conclusions, one-stage posterior debridement, interbody fusion, pedicle screw fixation and two-stage CT-guided interventional therapy were safe and effective in treatment of the thoracic and lumbar spinal tuberculosis with flow injection abscess. PMID:26770442

  2. [Video-assisted thoracic surgery, lung transplantation and mediastinitis: major issues in thoracic surgery in 2010].

    PubMed

    Borro, José M; Moreno, Ramón; Gómez, Ana; Duque, José Luis

    2011-01-01

    We reviewed the major issues in thoracic surgery relating to the advances made in our specialty in 2010. To do this, the 43(rd) Congress of the Spanish Society of Pneumology and Thoracic Surgery held in La Coruña and the articles published in the Society's journal, Archivos de Bronconeumología, were reviewed. The main areas of interest were related to the development of video-assisted thoracic surgery, lung transplantation and descending mediastinitis. The new tumor-node-metastasis (TNM) classification (7(th) edition), presented last year, was still a topical issue this year. The First Forum of Thoracic Surgeons and the Update in Thoracic Surgery together with the Nurses' Area have constituted an excellent teaching program. PMID:21300211

  3. Respiratory triggered 4D cone-beam computed tomography: A novel method to reduce imaging dose

    PubMed Central

    Cooper, Benjamin J.; O’Brien, Ricky T.; Balik, Salim; Hugo, Geoffrey D.; Keall, Paul J.

    2013-01-01

    Purpose: A novel method called respiratory triggered 4D cone-beam computed tomography (RT 4D CBCT) is described whereby imaging dose can be reduced without degrading image quality. RT 4D CBCT utilizes a respiratory signal to trigger projections such that only a single projection is assigned to a given respiratory bin for each breathing cycle. In contrast, commercial 4D CBCT does not actively use the respiratory signal to minimize image dose. Methods: To compare RT 4D CBCT with conventional 4D CBCT, 3600 CBCT projections of a thorax phantom were gathered and reconstructed to generate a ground truth CBCT dataset. Simulation pairs of conventional 4D CBCT acquisitions and RT 4D CBCT acquisitions were developed assuming a sinusoidal respiratory signal which governs the selection of projections from the pool of 3600 original projections. The RT 4D CBCT acquisition triggers a single projection when the respiratory signal enters a desired acquisition bin; the conventional acquisition does not use a respiratory trigger and projections are acquired at a constant frequency. Acquisition parameters studied were breathing period, acquisition time, and imager frequency. The performance of RT 4D CBCT using phase based and displacement based sorting was also studied. Image quality was quantified by calculating difference images of the test dataset from the ground truth dataset. Imaging dose was calculated by counting projections. Results: Using phase based sorting RT 4D CBCT results in 47% less imaging dose on average compared to conventional 4D CBCT. Image quality differences were less than 4% at worst. Using displacement based sorting RT 4D CBCT results in 57% less imaging dose on average, than conventional 4D CBCT methods; however, image quality was 26% worse with RT 4D CBCT. Conclusions: Simulation studies have shown that RT 4D CBCT reduces imaging dose while maintaining comparable image quality for phase based 4D CBCT; image quality is degraded for displacement based RT 4D

  4. Patient specific stress and rupture analysis of ascending thoracic aneurysms.

    PubMed

    Trabelsi, Olfa; Davis, Frances M; Rodriguez-Matas, Jose F; Duprey, Ambroise; Avril, Stéphane

    2015-07-16

    An ascending thoracic aortic aneurysm (ATAA) is a serious medical condition which, more often than not, requires surgery. Aneurysm diameter is the primary clinical criterion for determining when surgical intervention is necessary but, biomechanical studies have suggested that the diameter criterion is insufficient. This manuscript presents a method for obtaining the patient specific wall stress distribution of the ATAA and the retrospective rupture risk for each patient. Five human ATAAs and the preoperative dynamic CT scans were obtained during elective surgeries to replace each patient's aneurysm with a synthetic graft. The material properties and rupture stress for each tissue sample were identified using bulge inflation tests. The dynamic CT scans were used to generate patient specific geometries for a finite element (FE) model of each patient's aneurysm. The material properties from the bulge inflation tests were implemented in the FE model and the wall stress distribution at four different pressures was estimated. Three different rupture risk assessments were compared: the maximum diameter, the rupture risk index, and the overpressure index. The peak wall stress values for the patients ranged from 28% to 94% of the ATAA's failure stress. The rupture risk and overpressure indices were both only weakly correlated with diameter (ρ=-0.29, both cases). In the future, we plan to conduct a large experimental and computational study that includes asymptomatic patients under surveillance, patients undergoing elective surgery, and patients who have experienced rupture or dissection to determine if the rupture risk index or maximum diameter can meaningfully differentiate between the groups. PMID:25979384

  5. SU-D-17A-01: Geometric and Dosimetric Evaluation of a 4D-CBCT Reconstruction Technique Using Prior Knowledge

    SciTech Connect

    Zhang, Y; Yin, F; Ren, L

    2014-06-01

    Purpose: To evaluate a 4D-CBCT reconstruction technique both geometrically and dosimetrically Methods: A prior-knowledge guided 4DC-BCT reconstruction method named the motion-modeling and free-form deformation (MM-FD) has been developed. MM-FD views each phase of the 4D-CBCT as a deformation of a prior CT volume. The deformation field is first solved by principal component analysis based motion modeling, followed by constrained free-form deformation.The 4D digital extended-cardiac- torso (XCAT) phantom was used for comprehensive evaluation. Based on a simulated 4D planning CT of a lung patient, 8 different scenarios were simulated to cover the typical on-board anatomical and respiratory variations: (1) synchronized and (2) unsynchronized motion amplitude change for body and tumor; tumor (3) shrinkage and (4) expansion; tumor average position shift in (5) superior-inferior (SI) direction, (6) anterior-posterior (AP) direction and (7) SI, AP and lateral directions altogether; and (8) tumor phase shift relative to the respiratory cycle of the body. Orthogonal-view 30° projections were simulated based on the eight patient scenarios to reconstruct on-board 4D-CBCTs. For geometric evaluation, the volume-percentage-difference (VPD) was calculated to assess the volumetric differences between the reconstructed and the ground-truth tumor.For dosimetric evaluation, a gated treatment plan was designed for the prior 4D-CT. The dose distributions were calculated on the reconstructed 4D-CBCTs and the ground-truth images for comparison. The MM-FD technique was compared with MM-only and FD-only techniques. Results: The average (±s.d.) VPD values of reconstructed tumors for MM-only, FDonly and MM-FD methods were 59.16%(± 26.66%), 75.98%(± 27.21%) and 5.22%(± 2.12%), respectively. The average min/max/mean dose (normalized to prescription) of the reconstructed tumors by MM-only, FD-only, MM-FD methods and ground-truth tumors were 78.0%/122.2%/108.2%, 13%/117.7%/86%, 58

  6. Parallel Infrastructure Modeling and Inversion Module for E4D

    SciTech Connect

    2014-10-09

    Electrical resistivity tomography ERT is a method of imaging the electrical conductivity of the subsurface. Electrical conductivity is a useful metric for understanding the subsurface because it is governed by geomechanical and geochemical properties that drive subsurface systems. ERT works by injecting current into the subsurface across a pair of electrodes, and measuring the corresponding electrical potential response across another pair of electrodes. Many such measurements are strategically taken across an array of electrodes to produce an ERT data set. These data are then processed through a computationally demanding process known as inversion to produce an image of the subsurface conductivity structure that gave rise to the measurements. Data can be inverted to provide 2D images, 3D images, or in the case of time-lapse 3D imaging, 4D images. ERT is generally not well suited for environments with buried electrically conductive infrastructure such as pipes, tanks, or well casings, because these features tend to dominate and degrade ERT images. This reduces or eliminates the utility of ERT imaging where it would otherwise be highly useful for, for example, imaging fluid migration from leaking pipes, imaging soil contamination beneath leaking subusurface tanks, and monitoring contaminant migration in locations with dense network of metal cased monitoring wells. The location and dimension of buried metallic infrastructure is often known. If so, then the effects of the infrastructure can be explicitly modeled within the ERT imaging algorithm, and thereby removed from the corresponding ERT image. However,there are a number of obstacles limiting this application. 1) Metallic infrastructure cannot be accurately modeled with standard codes because of the large contrast in conductivity between the metal and host material. 2) Modeling infrastructure in true dimension requires the computational mesh to be highly refined near the metal inclusions, which increases

  7. 4D Dynamic RNP Annual Interim Report-Year 1

    NASA Technical Reports Server (NTRS)

    Finkelsztein, Daniel M.; Sturdy, James L.; Alaverdi, Omeed; Chung, William W.; Salvano, Daniel; Klooster, Joel; Hochwarth, Joachim K.

    2010-01-01

    This Annual Interim Report summarizes the activities led by Raytheon, in collaboration with GE Aviation and SAIC, and presents the results obtained during the first year of this research effort to expand the RNP concept to 4 dimensions relative to a dynamic frame of reference. Joint Program Development Office (JPDO)Concepts of Operations for the Next Generation Air Transportation System (NextGen) considers 4 Dimension Trajectory (4DT) procedures a key enabler to Trajectory Based Operations (TBO). The JPDO defines 4DT as a precise description of an aircraft path in space and time . While NextGen assumes that this path is defined within an Earth-reference frame, many 4DT procedure implementations will require an aircraft to precisely navigate relative to a moving reference such as another aircraft to form aggregate flows or a weather cell to allow for flows to shift. Current methods of implementing routes and flight paths rely on aircraft meeting a Required Navigation Performance (RNP) specification and being equipped with a monitoring and alerting capability to annunciate when the aircraft system is unable to meet the performance specification required for the operation. Since all aircraft t