Science.gov

Sample records for 60-hz transmission line

  1. Mitigation of 50-60 Hz power line interference in geophysical data

    NASA Astrophysics Data System (ADS)

    Cohen, M. B.; Said, R. K.; Inan, U. S.

    2010-12-01

    The analysis of ELF/VLF radio data has broad applications for ionospheric and magnetospheric phenomena, lightning activity, long-range communications, and geophysical prospecting. However, recordings of ELF/VLF data on the ground are adversely affected by the presence of electromagnetic fields from 50-60 Hz power lines, whose harmonics can extend to many kilohertz and interfere with the detection of natural and man-made signals. Removal of this interference is complicated by the time-varying fundamental frequency of power lines and strongly varying characteristics across different power grids. We discuss two methods for isolation and then subtraction of this interference, by an adaptive filtering technique and with least squares matrix analysis. Methods for estimating the time-varying frequency are also discussed. A few variants of these techniques are applied both to simulated data and then to real data. It is found that least squares isolation gives superior results, although the adaptive filter is potentially more effective for poorly behaved power line interference with rapidly changing fundamental frequencies as well as being computationally more efficient.

  2. Power line emission 50/60 Hz and Schumann resonances observed by microsatellite Chibis-M in the Earth's ionosphere

    NASA Astrophysics Data System (ADS)

    Dudkin, Denys; Pilipenko, Vyacheslav; Dudkin, Fedir; Pronenko, Vira; Klimov, Stanislav

    2015-04-01

    The overhead power lines are the sources of intense wideband electromagnetic (EM) emission, especially in ELF-VLF range, because of significant length (up to a few thousand kilometers) and strong 50/60 Hz currents with noticeable distortion. The radiation efficiency of the power line emission (PLE) increases with the harmonic order, so they are well observed by ground-based EM sensors. However their observations by low orbiting satellites (LEO) are very rare, particularly at basic harmonic 50/60 Hz, because of the ionospheric plasma opacity in ELF band. The Schumann resonance (SR) is the narrow-band EM noise that occurs due to the global thunderstorm activity in the Earth-ionosphere cavity. The first five eigenmodes of the SR are 7.8, 14.3, 20.8, 27.3 and 33.8 Hz and, thus, SR harmonics are also strongly absorbed by the Earth ionosphere. The published numerical simulations show that the penetration depth of such an ELF emission into the Earth's ionosphere is limited to 50-70 km for electric field and 120-240 km for magnetic field. From this follows, that PLE and SR can hardly ever be detected by LEO satellites, i.e. above the F-layer of ionosphere. In spite of this fact, these emissions were recently observed with use of the electric field antennas placed on the satellites C/NOFS (USA) and Chibis-M (Russia). Microsatellite Chibis-M was launched on January 24, 2012, at 23:18:30 UTC from the cargo ship "Progress M-13M" to circular orbit with altitude ~500 km and inclination ~52° . Chibis-M mass is about 40 kg where one third is a scientific instrumentation. The dimensions of the microsatellite case are 0.26x0.26x0.54 m with the outside mounted solar panels, service and scientific instrumentation. The main scientific objective of Chibis-M is the theoretical model verification for the atmospheric gamma-ray bursts. It requires the study of the accompanying EM processes such as the plasma waves produced by the lightning discharges in the VLF band. Chibis-M decayed on 15

  3. Power line harmonic radiation observed by the DEMETER spacecraft at 50/60 Hz and low harmonics

    NASA Astrophysics Data System (ADS)

    Němec, F.; Parrot, M.; Santolík, O.

    2015-10-01

    We present a low-altitude satellite survey of Power Line Harmonic Radiation (PLHR), i.e., electromagnetic waves radiated by electric power systems on the ground. We focus on frequencies corresponding to the first few harmonics of the base power system frequencies (50 Hz or 60 Hz, depending on the region). It is shown that the intensities of electromagnetic waves detected at these frequencies at an altitude of about 700 km are significantly enhanced above industrialized areas. The frequencies at which the wave intensities are increased are in excellent agreement with base power system frequencies just below the satellite location. We also investigate a possible presence of the weekend effect, i.e., if the situation is different during the weekends when the power consumption is lower than during the weekdays. Such an effect might be possibly present in the European region, but it is very weak. PLHR effects are less often detected in the summer, as the ionospheric absorption increases, and also, the radiation is obscured by lightning generated emissions. This difference is smaller in the U.S. region, in agreement with the monthly variations of the power consumption. The analysis of the measured frequency spectra reveals that although intensity increases at low odd harmonics of base power system frequencies are routinely detected, low even harmonics are generally absent. Finally, we verify the relation of PLHR intensities to the geomagnetically induced currents (GICs) proxy. It is shown that the PLHR intensity is increased at the times of higher GIC proxy values during the night.

  4. Effects of 60 Hz electric fields on operant and social stress behaviors of nonhuman primates

    SciTech Connect

    Rogers, W.R.; Coelho, A.M. Jr.; Easley, S.P.; Lucas, J.H.; Moore, G.T.; Orr, J.L.; Smith, H.D.; Taylor, L.L.; Tuttle, M.L.

    1987-10-24

    The objective of this program is to investigate, using the baboon as a nonhuman primate surrogate for the human, possible behavioral effects associated with exposure to high intensity 60 Hz electric fields. Results from this program, along with information from experiments conducted elsewhere, will be used by the Department of Energy (DOE) to estimate and evaluate the likelihood of deleterious consequences resulting from exposure of humans to the electric fields associated with power transmission over high voltage lines. This research program consists of four major research projects, all of which have been successfully completed. The first project evaluated the potentially aversive character of exposure to 60 Hz electric fields by determining the threshold intensity that produces escape or avoidance responses. The second project estimated the threshold intensity for detection threshold was 12 kV/m; the range of means was 6 to 16 kV/m. The third project assessed, in separate experiments conducted at 30 and 60 kV/m, effects of chronic exposure to electric fields on the performance of two operant conditioning tasks, fixed ratio (FR), and differential reinforcement of low rate (DRL). In the same two experiments, the fourth project investigated, using the systematic quantitative observational sampling methods of primatology, the possible stress-inducing effects of chronic exposure to 60 Hz electric fields on the behavior of baboons living in small social groups. 131 refs., 87 figs., 123 tabs.

  5. Effects of 60 Hz electrical fields on operant and social stress behaviors of nonhuman primates: Summary

    SciTech Connect

    Rogers, W.R.; Coelho, A.M. Jr.; Easley, S.P.; Orr, J.L.

    1988-04-06

    The objective of this program is to investigate, using the baboon as a nonhuman primate surrogate for the human, behavioral effects associated with exposure to 60-Hz electric fields. Results from this program, along with information from experiments conducted elsewhere, could be used to estimate and evaluate the likelihood of deleterious consequences resulting from exposure of humans to the electric fields associated with power transmission over high voltage lines. This program is being conducted at Southwest Research Institute as part of an international collaborative information exchange and scientific research effort involving the United State Department of Energy, Japan's Ministry of International Trade and Industry, and Japan's Central Research Institute of the Electric Power Industry. Since August of 1984, four major research projects were successfully completed. 48 refs., 12 figs., 2 tabs.

  6. Series Transmission Line Transformer

    DOEpatents

    Buckles, Robert A.; Booth, Rex; Yen, Boris T.

    2004-06-29

    A series transmission line transformer is set forth which includes two or more of impedance matched sets of at least two transmissions lines such as shielded cables, connected in parallel at one end ans series at the other in a cascading fashion. The cables are wound about a magnetic core. The series transmission line transformer (STLT) which can provide for higher impedance ratios and bandwidths, which is scalable, and which is of simpler design and construction.

  7. Behavioral and prenatal effects of 60-Hz fields

    SciTech Connect

    Not Available

    1983-08-01

    Purpose was to determine possible neural, behavioral, and reproductive effects of low-intensity 60-Hz electric fields on mammals (rats) exposed in-utero. The tests used shortly after birth included negative geotaxis, the acoustic startle response, surface righting, in-air righting, cliff avoidance, emotionality, and swimming endurance. Variations between the exposed and control groups are discussed. 9 tables. (DLC)

  8. EFFECTS OF 60-HZ FIELDS ON HUMAN HEALTH PARAMETERS

    EPA Science Inventory

    Specific results of research on the effects of exposure to 60-Hz electric and magnetic fields have often been contradictory and difficult to replicate. The study reported here used quantitative exercise testing techniques to evaluate whether increases in metabolism, caused by mod...

  9. Transmission Line Security Monitor

    SciTech Connect

    2011-01-01

    The Transmission Line Security Monitor is a multi-sensor monitor that mounts directly on high-voltage transmission lines to detect, characterize and communicate terrorist activity, human tampering and threatening conditions around support towers. For more information about INL's critical infrastructure protection research, visit http://www.facebook.com/idahonationallaboratory.

  10. Transmission Line Security Monitor

    ScienceCinema

    None

    2013-05-28

    The Transmission Line Security Monitor is a multi-sensor monitor that mounts directly on high-voltage transmission lines to detect, characterize and communicate terrorist activity, human tampering and threatening conditions around support towers. For more information about INL's critical infrastructure protection research, visit http://www.facebook.com/idahonationallaboratory.

  11. Effects of 60 Hz electric fields on operant and social stress behaviors of nonhuman primates: Projects 3 and 4

    SciTech Connect

    Rogers, W.R.; Coelho, A.M. Jr.; Easley, S.P.; Orr, J.L.; Smith, H.D.; Taylor, L.L.; Tuttle, M.L.

    1987-01-01

    The objective of this program is to investigate, using the baboon as a nonhuman primate surrogate for the human, possible hehavioral effects associated with exposure to high intensity 60 Hz electric fields. Results from this program, along with information from experiments conducted elsewhere, will be used by the Department of Energy (DOE) to estimate and evaluate the likelihood of deleterious consequences resulting from exposure of humans to the electric fields associated with power transmission over high voltage lines. This research program consists of four major research projects, all of which have been successfully completed. The third project assessed, in separate experiments conducted at 30 and 60 kV/m, effects of chronic exposure to electric fields on the performance of two operant conditioning tasks, fixed ratio (FR), and differential reinforcement of low rate (DRL). In the same two experiments, the fourth project investigated, using the systematic quantitative observational sampling methods of primatology, the possible stress-inducing effects of chronic exposure to 60 Hz electric fields on the behavior of baboons living in small social groups. This volume contains only appendices for projects 3 and 4. 81 figs., 67 tabs.

  12. Residential 60-Hz magnetic fields and temporal variability

    NASA Astrophysics Data System (ADS)

    Banks, Robert Stephen

    1998-06-01

    The basic question addressed by this research is: How well can data from a single measurement visit estimate longer-term ambient residential 60-Hz magnetic field levels? We undertook repeat 60-Hz magnetic field measurements every two months for one year, plus one additional visit for 14 days of measurement. The study sample consisted of 51 single-family homes, 24 in Minneapolis-St. Paul and 27 in Detroit. Homes were selected by random-digit dialing; each was home to a child eligible to serve a control subject in the National Cancer Institute-Children's Cancer Group Electromagnetic Fields and Radon Study. Trained survey interviewers obtained all measurement data, using an expanded measurement protocol from the main study: (1) spot 60-Hz magnetic field measurements at the centers of three rooms and at the front door; (2) 24- hour (or 14 day) 60-Hz magnetic field measurement in the subject child's bedroom; and (3) geomagnetic field at the centers of two rooms and on the child's bed. The data set available for analysis consists of 349 out of 357 (97.8%) possible sets of spot measurements and 1060 out of 1071 (99.0%) possible days of 24-hour and two-week measurements. A Long-Term Estimate, Child's Bedroom, or LTECB, the geometric mean of the 24-hour measurement geometric means, was used as the reference for analysis. The LTECB was analyzed for house-level main effects and for repeated-measures (temporal) main effects. House-level main effects account for only 41% of the variability in the LTECB. The statistically significant main effects are study area, wire code and population density. A clear trend of increasing LTECB with population density is evident. The seasonal effect is small, but statistically significant. There is no evidence for a day-of-week effect, but a statistically significant diurnal effect is present. Correlation coefficients relating the LTECB to any of three primary single-visit measurement and exposure metric surrogates are >.9. However, when

  13. Endocrinological effects of strong 60-Hz electric fields on rats

    SciTech Connect

    Free, M.J.; Kaune, W.T.; Phillips, R.D.; Cheng, H.C.

    1981-01-01

    Adult male rats were exposed or sham-exposed to 60-Hz electric fields without spark discharges, ozone, or significant levels or other secondary variables. No effects were discharges, ozone, or significant levels of other secondary variables. No effects were observed on body weights or plasma hormone levels after 30 days of exposure at an effective field strength of 68 kV/m. After 120 days of exposure (effective field strength = 64 kV/m), effects were inconsistent, with signficant reductions in body weight and plasma levels of follicle-stimulating hormone and corticosterone occurring in one replicate experiment but not in the other. Plasma testosterone levels were significantly reduced after 120 days of exposure in one experiment, with a similar but not statistically significant reduction in a replicate experiment. Weanling rats, exposed or sham-exposed in electric fields with an effective field strength of 80 kV/m from 20 to 56 days of age, exhibited identical or closely similar growth trends in body and organ weights. Hormone levels in exposed and sham-exposed groups were also similar. However, there was an apparent phase shift between the two groups in the cyclic variations of concentrations of hormones at different stages of development, particularly with respect to follicle-stimulating hormone and corticosterone. We concluded that 60-Hz electric fields may bring about subtle changes in the endocrine system of rats, and that these changes may be related to alterations in episodic rhythms.

  14. Harmonics of 60 Hz in power systems caused by geomagnetic disturbances. [Manitoba

    NASA Technical Reports Server (NTRS)

    Hayashi, K.; Oguti, T.; Watanabe, T.; Tsuruda, K.; Kokubun, S.; Horita, R. E.

    1979-01-01

    Simultaneous VLF/ULF observations carried out near Winnipeg, Manitoba show that geomagnetic disturbances control the behavior of harmonics of 60 Hz man-made electric power. The harmonics of 60 Hz detected by the VLF receiver are at multiples of 180 Hz, indicating that they originated from a 3 phase ac power system. Under geomagnetically quiet conditions, only odd harmonics of 70 Hz were detected. In disturbed conditions, both odd and even harmonics were excited. The strength of each harmonic changed concurrently with geomagnetic pulsation (ULF) activity. These findings seem to indicate that a portion of telluric currents shunted into the power line system through the neutrals of the Y-connected transformers give rise to a dc bias to the transformer core materials and that it distorts their hysteresis loops, activating harmonics of 60 Hz power. A mathematical proof is given that a hysteresis loop having a point of symmetry generates odd harmonics only, whereas loops lacking in point-symmetry generally give rise to both odd and even harmonics. A general formula was obtained to calculate the strength of each harmonic based on the shape of the hysteresis loop.

  15. Printed circuit dispersive transmission line

    DOEpatents

    Ikezi, H.; Lin-Liu, Y.R.; DeGrassie, J.S.

    1991-08-27

    A printed circuit dispersive transmission line structure is disclosed comprising an insulator, a ground plane formed on one surface of the insulator, a first transmission line formed on a second surface of the insulator, and a second transmission line also formed on the second surface of the insulator and of longer length than the first transmission line and periodically intersecting the first transmission line. In a preferred embodiment, the transmission line structure exhibits highly dispersive characteristics by designing the length of one of the transmission line between two adjacent periodic intersections to be longer than the other. 5 figures.

  16. Printed circuit dispersive transmission line

    DOEpatents

    Ikezi, Hiroyuki; Lin-Liu, Yuh-Ren; DeGrassie, John S.

    1991-01-01

    A printed circuit dispersive transmission line structure is disclosed comprising an insulator, a ground plane formed on one surface of the insulator, a first transmission line formed on a second surface of the insulator, and a second transmission line also formed on the second surface of the insulator and of longer length than the first transmission line and periodically intersecting the first transmission line. In a preferred embodiment, the transmission line structure exhibits highly dispersive characteristics by designing the length of one of the transmission line between two adjacent periodic intersections to be longer than the other.

  17. Influence of 60-Hz magnetic fields on sea urchin development

    SciTech Connect

    Zimmerman, S.; Zimmerman, A.M.; Winters, W.D.; Cameron, I.L. )

    1990-01-01

    Continuous exposure of sea urchin (Strongylocentrotus purpuratus) embryos at 18 degrees C to a cyclic 60-Hz magnetic field at 0.1 mT rms beginning 4 min after insemination caused a significant developmental delay during the subsequent 23 hours. No delay in development was recorded for periods up to 18 hours after fertilization. At 18 h, most embryos were in the mesenchyme blastula stage. At 23 h, most control embryos were in mid-gastrula whereas most magnetic-field-exposed embryos were in the early gastrula stage. Thus an estimated 1-h delay occurred between these developmental stages. The results are discussed in terms of possible magnetic-field modification of transcription as well as interference with cell migration during gastrulation. The present study extends and supports the growing body of information about potential effects of exposures to extremely-low-frequency (ELF) magnetic fields on developing organisms.

  18. Drill string transmission line

    DOEpatents

    Hall, David R.; Hall, Jr., H. Tracy; Pixton, David S.; Bradford, Kline; Fox, Joe

    2006-03-28

    A transmission line assembly for transmitting information along a downhole tool comprising a pin end, a box end, and a central bore traveling between the pin end and the box end, is disclosed in one embodiment of the invention as including a protective conduit. A transmission line is routed through the protective conduit. The protective conduit is routed through the central bore and the ends of the protective conduit are routed through channels formed in the pin end and box end of the downhole tool. The protective conduit is elastically forced into a spiral or other non-linear path along the interior surface of the central bore by compressing the protective conduit to a length within the downhole tool shorter than the protective conduit.

  19. Cardiovascular response of rats exposed to 60-Hz electric fields

    SciTech Connect

    Hilton, D.I.; Phillips, R.D.

    1980-01-01

    Recently, it has been reported that exposure to high-strength electric fields can influence electrocardiogram (ECG) patterns, heart rates, and blood pressures in various species of animals. Our studies were designed to evaluate these reported effects and to help clarify some of the disagreement present in the literature. Various cardiovascular variables were measured in Sprague-Dawley rats exposed or sham-exposed to 60-Hz electric fields at 80 to 100 kV/m for periods up to four months. No significant differences in heart rates, ECG patterns, blood pressures, or vascular reactivity were observed between exposed and sham-exposed rats after 8 hours, 40 hours, 1 month, or 4 months of exposure. Our studies cannot be directly compared to the work of other investigators because of differences in animal species and electric-field characteristics. However, our failure to detect any cardiovascular changes may have been the result of (1) eliminating secondary field effects such as shocks, audible noise, corona, and ozone; (2) minimizing steady-state microcurrents between the mouth of the animal and watering devices; and (3) minimizing electric-field-induced vibration of the electrodes and animal cages.

  20. A Quantitative Transmission Line Experiment

    ERIC Educational Resources Information Center

    Johnston, D. C.; Silbernagel, B. G.

    1969-01-01

    Describes modifications of a commercially available strip-type transmission line, which makes possible reproducible measurements of standing waves on the line. Experimental data yield values for the characteristic impedance, phase velocity and line wavelength of radiation in the transmission line, and the dielectric constant of material in the…

  1. EC Transmission Line Materials

    SciTech Connect

    Bigelow, Tim S

    2012-05-01

    The purpose of this document is to identify materials acceptable for use in the US ITER Project Office (USIPO)-supplied components for the ITER Electron cyclotron Heating and Current Drive (ECH&CD) transmission lines (TL), PBS-52. The source of material property information for design analysis shall be either the applicable structural code or the ITER Material Properties Handbook. In the case of conflict, the ITER Material Properties Handbook shall take precedence. Materials selection, and use, shall follow the guidelines established in the Materials Assessment Report (MAR). Materials exposed to vacuum shall conform to the ITER Vacuum Handbook. [Ref. 2] Commercial materials shall conform to the applicable standard (e.g., ASTM, JIS, DIN) for the definition of their grade, physical, chemical and electrical properties and related testing. All materials for which a suitable certification from the supplier is not available shall be tested to determine the relevant properties, as part of the procurement. A complete traceability of all the materials including welding materials shall be provided. Halogenated materials (example: insulating materials) shall be forbidden in areas served by the detritiation systems. Exceptions must be approved by the Tritium System and Safety Section Responsible Officers.

  2. Chronic exposure to a 60-Hz electric field: effects on neuromuscular function in the rat

    SciTech Connect

    Jaffe, R.A.; Laszewski, B.L.; Carr, D.B.

    1981-01-01

    Neuromuscular function in adult male rats was studied following 30 days of exposure to a 60-Hz electric field at 100 kV/m (unperturbed field strength). Isometric force transducters were attached to the tendons of the plantaris (predominantly fast twitch), and soleus (predominantly slow twitch) muscles in the urethan-anesthetized rat. Square-wave stimuli were delivered to the distal stump of the transected sciatic nerve. Several measurements were used to characterize neuromuscular function, including twitch characteristics, chronaxie, tetanic and posttetanic potentiation, and fatigue and recovery. The results from three independent series of experiments are reported. Only recovery from fatigue in slow-twitch muscles was consistently and significantly affected (enhanced) by electric-field exposure. This effect does not appear to be mediated by field-induced changes in either neuromuscular transmission, or in the contractile mechanism itself. It is suggested that the effect may be mediated secondary to an effect on mechanisms regulating muscle blood flow or metabolism.

  3. Electrical transmission line diametrical retainer

    DOEpatents

    Hall, David R.; Hall, Jr., H. Tracy; Pixton, David; Dahlgren, Scott; Sneddon, Cameron; Briscoe, Michael; Fox, Joe

    2004-12-14

    The invention is a mechanism for retaining an electrical transmission line. In one embodiment of the invention it is a system for retaining an electrical transmission line within down hole components. In accordance with one aspect of the invention, the system includes a plurality of downhole components, such as sections of pipe in a drill string. The system also includes a coaxial cable running between the first and second end of a drill pipe, the coaxial cable having a conductive tube and a conductive core within it. The invention allows the electrical transmission line to with stand the tension and compression of drill pipe during routine drilling cycles.

  4. Effects of 60 Hz electric fields on operant and social stress behaviors of nonhuman primates

    SciTech Connect

    Rogers, W.R.; Lucas, J.H.; Moore, G.T.; Orr, J.L.

    1985-01-01

    An overall description of this research program is presented. The objectives are to investigate using nonhuman primates, possible behavioral effects associated with exposure to high-intensity, 60 Hz, electric fields. 6 tabs.

  5. Effects of a 60 Hz Magnetic Field Exposure Up to 3000 μT on Human Brain Activation as Measured by Functional Magnetic Resonance Imaging

    PubMed Central

    Legros, Alexandre; Modolo, Julien; Brown, Samantha; Roberston, John; Thomas, Alex W.

    2015-01-01

    Several aspects of the human nervous system and associated motor and cognitive processes have been reported to be modulated by extremely low-frequency (ELF, < 300 Hz) time-varying Magnetic Fields (MF). Due do their worldwide prevalence; power-line frequencies (60 Hz in North America) are of particular interest. Despite intense research efforts over the last few decades, the potential effects of 60 Hz MF still need to be elucidated, and the underlying mechanisms to be understood. In this study, we have used functional Magnetic Resonance Imaging (fMRI) to characterize potential changes in functional brain activation following human exposure to a 60 Hz MF through motor and cognitive tasks. First, pilot results acquired in a first set of subjects (N=9) were used to demonstrate the technical feasibility of using fMRI to detect subtle changes in functional brain activation with 60 Hz MF exposure at 1800 μT. Second, a full study involving a larger cohort of subjects tested brain activation during 1) a finger tapping task (N=20), and 2) a mental rotation task (N=21); before and after a one-hour, 60 Hz, 3000 μT MF exposure. The results indicate significant changes in task-induced functional brain activation as a consequence of MF exposure. However, no impact on task performance was found. These results illustrate the potential of using fMRI to identify MF-induced changes in functional brain activation, suggesting that a one-hour 60 Hz, 3000 μT MF exposure can modulate activity in specific brain regions after the end of the exposure period (i.e., residual effects). We discuss the possibility that MF exposure at 60 Hz, 3000 μT may be capable of modulating cortical excitability via a modulation of synaptic plasticity processes. PMID:26214312

  6. Investigation of effects of 60-Hz electric and magnetic fields on operant and social behavior and on the neuroendocrine system of nonhuman primates

    SciTech Connect

    Rhodes, J.W.

    1992-09-24

    The objective of this program is to investigate behavioral and neuroendocrine effects associated with exposure to 60-Hz electric and magnetic fields (E/MF), using the baboon (Papio cynocephalus) as a nonhuman primate surrogate for the human. Results from this program, along with information from experiments conducted elsewhere, could be used to estimate and evaluate the likelihood of deleterious consequences of human exposure to the electric and magnetic fields associated with electric power transmission. This report covers a series of three experiments (Experiments III, IV, and IVA) on the effect of combined 60-Hz E/MF on operant behavior. These experiments were a continuation of previous investigations of 60-Hz electric field exposure on baboons.

  7. Nonceramic insulators for transmission lines

    SciTech Connect

    Schneider, H.M. . High Voltage Transmission Research Center); Hall, J.F. ); Karady, G. ); Rendowden, J. )

    1989-10-01

    Progress in development of nonceramic transmission lines insulator technology is reviewed. The results of a survey to utilities in the United States are presented to indicate the range of applications, distribution by voltage class, appraisal of performance, and failure modes. Concerns expressed by utility representatives at a recent workshop are described and future research and standardization needs are presented.

  8. Pulse shaping with transmission lines

    DOEpatents

    Wilcox, R.B.

    1985-08-15

    A method and apparatus for forming shaped voltage pulses uses passive reflection from a transmission line with nonuniform impedance. The impedance of the reflecting line varies with length in accordance with the desired pulse shape. A high voltage input pulse is transmitted to the reflecting line. A reflected pulse is produced having the desired shape and is transmitted by pulse removal means to a load. Light activated photoconductive switches made of silicon can be utilized. The pulse shaper can be used to drive a Pockels cell to produce shaped optical pulses.

  9. Pulse shaping with transmission lines

    DOEpatents

    Wilcox, Russell B.

    1987-01-01

    A method and apparatus for forming shaped voltage pulses uses passive reflection from a transmission line with nonuniform impedance. The impedance of the reflecting line varies with length in accordance with the desired pulse shape. A high voltage input pulse is transmitted to the reflecting line. A reflected pulse is produced having the desired shape and is transmitted by pulse removal means to a load. Light activated photoconductive switches made of silicon can be utilized. The pulse shaper can be used to drive a Pockels cell to produce shaped optical pulses.

  10. Coiled transmission line pulse generators

    DOEpatents

    McDonald, Kenneth Fox

    2010-11-09

    Methods and apparatus are provided for fabricating and constructing solid dielectric "Coiled Transmission Line" pulse generators in radial or axial coiled geometries. The pour and cure fabrication process enables a wide variety of geometries and form factors. The volume between the conductors is filled with liquid blends of monomers, polymers, oligomers, and/or cross-linkers and dielectric powders; and then cured to form high field strength and high dielectric constant solid dielectric transmission lines that intrinsically produce ideal rectangular high voltage pulses when charged and switched into matched impedance loads. Voltage levels may be increased by Marx and/or Blumlein principles incorporating spark gap or, preferentially, solid state switches (such as optically triggered thyristors) which produce reliable, high repetition rate operation. Moreover, these Marxed pulse generators can be DC charged and do not require additional pulse forming circuitry, pulse forming lines, transformers, or an a high voltage spark gap output switch. The apparatus accommodates a wide range of voltages, impedances, pulse durations, pulse repetition rates, and duty cycles. The resulting mobile or flight platform friendly cylindrical geometric configuration is much more compact, light-weight, and robust than conventional linear geometries, or pulse generators constructed from conventional components. Installing additional circuitry may accommodate optional pulse shape improvements. The Coiled Transmission Lines can also be connected in parallel to decrease the impedance, or in series to increase the pulse length.

  11. Large Granular Lymphocytic (LGL) Leukemia in Rats Exposed to Intermittent 60 Hz Magnetic Fields

    SciTech Connect

    Anderson, Larry E.); Morris, James E.); Miller, Douglas L.); Ebi, K L.; Sasser, Lyle B.)

    2001-04-01

    An animal model for large granular lymphocytic (LGL) leukemia in male Fischer 344 rats utilized to determine whether magnetic field exposure can be shown to influence the progression of leukemia. We previously reported that exposure to continuous 60 Hz 1 mT magnetic fields did not significantly alter the clinical progression of LGL leukemia in young male rats following inspection of spleen cells from donor leukemic rats. Results presented here extend those studies with the objectives to (1) replicate the previous study of continuous 60-Hz magnetic field exposures but using fewer LGL cells in the inoculum, and (2) determine if intermittent 60-Hz magnetic fields can alter the clinical progression of leukemia.

  12. 18 CFR 2.2 - Transmission lines.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Transmission lines. 2.2... Under the Federal Power Act § 2.2 Transmission lines. In a public statement dated March 7, 1941, the Commission announced its determination that transmission lines which are not primary lines transmitting...

  13. 18 CFR 2.2 - Transmission lines.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 18 Conservation of Power and Water Resources 1 2014-04-01 2014-04-01 false Transmission lines. 2.2... Under the Federal Power Act § 2.2 Transmission lines. In a public statement dated March 7, 1941, the Commission announced its determination that transmission lines which are not primary lines transmitting...

  14. 18 CFR 2.2 - Transmission lines.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 18 Conservation of Power and Water Resources 1 2012-04-01 2012-04-01 false Transmission lines. 2.2... Under the Federal Power Act § 2.2 Transmission lines. In a public statement dated March 7, 1941, the Commission announced its determination that transmission lines which are not primary lines transmitting...

  15. 18 CFR 2.2 - Transmission lines.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 18 Conservation of Power and Water Resources 1 2013-04-01 2013-04-01 false Transmission lines. 2.2... Under the Federal Power Act § 2.2 Transmission lines. In a public statement dated March 7, 1941, the Commission announced its determination that transmission lines which are not primary lines transmitting...

  16. 18 CFR 2.2 - Transmission lines.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 18 Conservation of Power and Water Resources 1 2011-04-01 2011-04-01 false Transmission lines. 2.2... Under the Federal Power Act § 2.2 Transmission lines. In a public statement dated March 7, 1941, the Commission announced its determination that transmission lines which are not primary lines transmitting...

  17. Effects of 60-Hz electric fields on living plants exposed for extended periods. Final report

    SciTech Connect

    Not Available

    1985-07-01

    The effects of intense 60-Hz electric fields were studied by exposing plants of five kinds (crops) for extended periods in a special greenhouse where cultural and environmental factors could be controlled. Plant populations and densities simulated field conditions. While exposed, plants of all crops germinated satisfactorily, and plants of sweet corn and wheat completed their life cycles and produced viable seed. Plants of alfalfa and tall fescue were at the early bloom stage when harvested. Exposure of plants of five kinds to electric fields had no statistically significant effects on seed germination, seedling growth, plant growth, phenology, flowering, seed set, biomass production, plant height, leaf area, plant survival, and nodulation. Exposure to 60-Hz electric fields resulted in very limited damage to terminal leaf tips, awns, and corn tassels, particularly at fields of 30 kV/m or greater. 47 refs., 36 figs., 44 tabs.

  18. Investigation of effects of 60-Hz electric and magnetic fields on operant and social behavior and on the neuroendocrine system of nonhuman primates

    SciTech Connect

    Smith, H.D.

    1993-01-22

    The objective of this program is to investigate behavioral and neuroendocrine effects associated with exposure to 60-Hz electric and magnetic fields (E/MF), using the baboon (Papio cynocephalus) as a nonhuman primate surrogate for the human. Results from this program, along with information from experiments conducted elsewhere, could be used to estimate and evaluate the likelihood of deleterious consequences of human exposure to the electric and magnetic fields associated with electric power transmission.

  19. Investigation of effects of 60-Hz electric and magnetic fields on operant and social behavior and on the neuroendocrine system of nonhuman primates. Annual report, FY1992

    SciTech Connect

    Smith, H.D

    1993-01-22

    The objective of this program is to investigate behavioral and neuroendocrine effects associated with exposure to 60-Hz electric and magnetic fields (E/MF), using the baboon (Papio cynocephalus) as a nonhuman primate surrogate for the human. Results from this program, along with information from experiments conducted elsewhere, could be used to estimate and evaluate the likelihood of deleterious consequences of human exposure to the electric and magnetic fields associated with electric power transmission.

  20. Effects of 60-Hz electric fields on embryo and chick development, growth, and behavior. Final report

    SciTech Connect

    Not Available

    1985-07-01

    The objective of this study was to utilize an avian model to determine the effects of 60-Hz electric fields on embryo and chick development. A specially designed incubator allowed simultaneous incubation of control eggs and eggs exposed to 60-Hz electric fields. Two series of experimental voltages were utilized for this study. In Series 1, the subject eggs were exposed to 20, 40, 60, 80, and 100 kV/m fields and, in Series 2, eggs were exposed to 0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50, and 100 kV/m. Data were collected on mortality, malformation, and growth (weight) of 7- and 14-day-old embryos after continuous exposure to electric fields. Eggs were also incubated, exposed to electric fields, and hatched in order to collect data on chick weights at one day and at 2, 4, and 6 weeks after hatching. Behavior tests on newly hatched chicks that had been exposed to electric fields during development were also performed. The results indicated no consistent effect of 60-Hz electric fields, varying from 0.1 to 100 kV/m, on mortality, malformations, weights, bone growth (metatarsal length), or behavior of embryos or chicks. This study strongly suggests that within the scope of this project, there is no consistent direct effect of 60 Hz electric fields on the health and well-being of avian embryos. A dose-response analysis was also utilized in which all the data in each series, for each age of the embryos, were simultaneously evaluated in a statistical model. This analysis demonstrated that there is no significant dose-response of electric fields on 7- and 14-day-old embryo and 1-day-old chick weights. 24 refs., 21 figs., 56 tabs.

  1. Superconducting transmission line particle detector

    DOEpatents

    Gray, Kenneth E.

    1989-01-01

    A microvertex particle detector for use in a high energy physic collider including a plurality of parallel superconducting thin film strips separated from a superconducting ground plane by an insulating layer to form a plurality of superconducting waveguides. The microvertex particle detector indicates passage of a charged subatomic particle by measuring a voltage pulse measured across a superconducting waveguide caused by the transition of the superconducting thin film strip from a superconducting to a non-superconducting state in response to the passage of a charged particle. A plurality of superconducting thin film strips in two orthogonal planes plus the slow electromagnetic wave propogating in a superconducting transmission line are used to resolve N.sup.2 ambiguity of charged particle events.

  2. Superconducting transmission line particle detector

    DOEpatents

    Gray, K.E.

    1988-07-28

    A microvertex particle detector for use in a high energy physic collider including a plurality of parallel superconducting thin film strips separated from a superconducting ground plane by an insulating layer to form a plurality of superconducting waveguides. The microvertex particle detector indicates passage of a charged subatomic particle by measuring a voltage pulse measured across a superconducting waveguide caused by the transition of the superconducting thin film strip from a superconducting to a non- superconducting state in response to the passage of a charged particle. A plurality of superconducting thin film strips in two orthogonal planes plus the slow electromagnetic wave propagating in a superconducting transmission line are used to resolve N/sup 2/ ambiguity of charged particle events. 6 figs.

  3. Magnetically insulated transmission line oscillator

    DOEpatents

    Bacon, L.D.; Ballard, W.P.; Clark, M.C.; Marder, B.M.

    1987-05-19

    A magnetically insulated transmission line oscillator employs self-generated magnetic fields to generate microwave energy. An anode of the oscillator includes slow-wave structures which are formed of a plurality of thin conductive vanes defining cavities therebetween, and a gap is formed between the anode and a cathode of the oscillator. In response to a pulsed voltage applied to the anode and cathode, self-generated magnetic fields are produced in a cross-field orientation with respect to the orientation of the electric field between the anode and the cathode. The cross-field magnetic fields insulate the flow of electrons in the gap and confine the flow of electrons within the gap. 11 figs.

  4. Magnetically insulated transmission line oscillator

    DOEpatents

    Bacon, Larry D.; Ballard, William P.; Clark, M. Collins; Marder, Barry M.

    1988-01-01

    A magnetically insulated transmission line oscillator employs self-generated magnetic fields to generate microwave energy. An anode of the oscillator includes slow-wave structures which are formed of a plurality of thin conductive vanes defining cavities therebetween, and a gap is formed between the anode and a cathode of the oscillator. In response to a pulsed voltage applied to the anode and cathode, self-generated magnetic fields arfe produced in a cross-field orientation with respect to the orientation of the electric field between the anode and the cathode. The cross-field magnetic fields insulate the flow of electrons in the gap and confine the flow of electrons within the gap.

  5. Wireless Sensor Network for Electric Transmission Line Monitoring

    SciTech Connect

    Alphenaar, Bruce

    2009-06-30

    , it has been demonstrated in this project that wireless monitoring units can effectively deliver real-time transmission line power flow information for less than $500 per monitor. The data delivered by such a monitor has during the course of the project been integrated with a national grid situational awareness visualization platform developed by Oak Ridge National Laboratory. Novel vibration energy scavenging methods based on piezoelectric cantilevers were also developed as a proposed method to power such monitors, with a goal of further cost reduction and large-scale deployment. Scavenging methods developed during the project resulted in 50% greater power output than conventional cantilever-based vibrational energy scavenging devices typically used to power smart sensor nodes. Lastly, enhanced and new methods for electromagnetic field sensing using multi-axis magnetometers and infrared reflectometry were investigated for potential monitoring applications in situations with a high density of power lines or high levels of background 60 Hz noise in order to isolate power lines of interest from other power lines in close proximity. The goal of this project was to investigate and demonstrate the feasibility of using small form factor, highly optimized, low cost, low power, non-contact, wireless electric transmission line monitors for delivery of real-time, independent power line monitoring for the US power grid. The project was divided into three main types of activity as follows; (1) Research into expanding the range of applications for non-contact power line monitoring to enable large scale low cost sensor network deployments (Tasks 1, 2); (2) Optimization of individual sensor hardware components to reduce size, cost and power consumption and testing in a pilot field study (Tasks 3,5); and (3) Demonstration of the feasibility of using the data from the network of power line monitors via a range of custom developed alerting and data visualization applications to deliver

  6. Seasonal Patterns of Melatonin, Cortisol, and Progesterone Secretion in Female Lambs Raised Beneath a 500-kV Transmission Line.

    SciTech Connect

    Lee, Jack M.

    1992-06-01

    Although several kinds of biological effects of electric and magnetic fields have been reported from laboratory studies, few have been independently replicated. When this study was being planned, the suppression of nighttime melatonin in rodents was thought to represent one of the strongest known effects of these fields. The effect had been replicated by a single laboratory for 60-Hz electric fields, and by multiple laboratories for d-c magnetic fields. The primary objective of this study was to determine whether the effect of electric and magnetic fields on melatonin would also occur in sheep exposed to a high voltage transmission line. The specific hypothesis tested by this experiment was as follows: The electrical environment produced by a 60-Hz, 500-kV transmission line causes a depression in nocturnal melatonin in chronically exposed female lambs. This may mimic effects of pinealectomy or constant long-day photoperiods, thus delaying the onset of reproductive cycles. Results of the study do not provide evidence to support the hypothesis. Melatonin concentrations in the sheep exposed to the transmission line showed the normal pattern of low daytime and high nighttime serum levels. As compared to the control group, there were no statistically significant group differences in the mean amplitude, phase, or duration of the nighttime melatonin elevation.

  7. Investigation of effects of 60-Hz electric and magnetic fields on operant and social behavior and on the neuroendocrine system of nonhuman primates

    SciTech Connect

    Orr, J.L.

    1990-04-01

    The objective of this program is to investigate, using the baboon as a nonhuman primate surrogate for the human, behavioral and neuroendocrine effects associated with exposure to 60-Hz electric and magnetic fields. Results from this program, along with information from experiments conducted elsewhere, could be used to estimate and evaluate the likelihood of deleterious consequences resulting from exposure of humans to the electric and magnetic fields associated with electric power transmission. Activities this quarter extended those of the first project year: the modification of the facility to include 60-Hz magnetic fields, and development of the capability for studies of neuroendocrine parameters by obtaining blood samples from baboons during electric and magnetic field exposure. 18 figs., 7 tabs.

  8. Investigation of effects of 60-Hz electric and magnetic fields on operant and social behavior and on the neuroendocrine systems of nonhuman primates

    SciTech Connect

    Orr, J.L.

    1990-01-01

    The objective of this program is to investigate, using the baboon as a nonhuman primate surrogate for the human, behavioral and neuroendocrine effects associated with exposure to 60-Hz electric and magnetic fields. Results from this program, along with information from experiments conducted elsewhere, could be used to estimate and evaluate the likelihood of deleterious consequences resulting from exposure of humans to the electric and magnetic fields associated with electric power transmission. Activities this quarter extended those of the first project year which focused on two technical areas: the modification of the facility to include 60-Hz magnetic fields, and development of the capability for studies of neuroendocrine parameters by obtaining blood samples from baboons during electric and magnetic field exposure. 25 figs., 11 tabs.

  9. Comparison of cardiac and 60 Hz magnetically induced electric fields measured in anesthetized rats

    SciTech Connect

    Miller, D.L.; Creim, J.A.

    1997-06-01

    Extremely low frequency magnetic fields interact with an animal by inducing internal electric fields, which are in addition to the normal endogenous fields present in living animals. Male rats weighing about 560 g each were anesthetized with ketamine and xylazine. Small incisions were made in the ventral body wall at the chest and upper abdomen to position a miniature probe for measuring internal electric fields. The calibration constant for the probe size was 5.7 mm, with a flat response from at least 12 Hz to 20 kHz. A cardiac signal, similar to the normal electrocardiogram with a heart rate of about 250 bpm, was readily obtained at the chest. Upon analysis of its spectrum, the cardiac field detected by the probe had a broad maximum at 32--95 Hz. When the rates were exposed to a 1 mT, 60 Hz magnetic field, a spike appeared in the spectrum at 60 Hz. The peak-to-peak magnitudes of electric fields associated with normal heart function were comparable to fields induced by a 1 mT magnetic field at 60 Hz for those positions measured on the body surface. Within the body, or in different directions relative to the applied field, the induced fields were reduced. The cardiac field increased near the heart, becoming much larger than the induced field. Thus, the cardiac electric field, together with the other endogenous fields, combine with induced electric fields and help to provide reference levels for the induced-field dosimetry of ELF magnetic field exposures of living animals.

  10. RF Transmission Lines on Silicon Substrates

    NASA Technical Reports Server (NTRS)

    Ponchak, George E.

    1999-01-01

    A review of RF transmission lines on silicon substrates is presented. Through measurements and calculated results, it is shown that attenuation is dominated by conductor loss if silicon substrates with a resistivity greater than 2500 Ohm-cm are used. Si passivation layers affect the transmission line attenuation; however, measured results demonstrate that passivation layers do not necessarily increase attenuation. If standard, low resistivity Si wafers must be used, alternative transmission lines such as thin film microstrip and Co-Planar Waveguide (CPW) on thick polyimide layers must be used. Measured results presented here show that low loss per unit length is achievable with these transmission lines.

  11. Transmission Line Security Monitor: Final Report

    SciTech Connect

    John Svoboda

    2011-04-01

    The Electric Power Transmission Line Security Monitor System Operational Test is a project funded by the Technical Support Working Group (TSWG). TSWG operates under the Combating Terrorism Technical Support Office that functions under the Department of Defense. The Transmission Line Security Monitor System is based on technology developed by Idaho National Laboratory. The technology provides a means for real-time monitoring of physical threats and/or damage to electrical transmission line towers and conductors as well as providing operational parameters to transmission line operators to optimize transmission line operation. The end use is for monitoring long stretches of transmission lines that deliver electrical power from remote generating stations to cities and industry. These transmission lines are generally located in remote transmission line corridors where security infrastructure may not exist. Security and operational sensors in the sensor platform on the conductors take power from the transmission line and relay security and operational information to operations personnel hundreds of miles away without relying on existing infrastructure. Initiated on May 25, 2007, this project resulted in pre-production units tested in realistic operational environments during 2010. A technology licensee, Lindsey Manufacturing of Azusa California, is assisting in design, testing, and ultimately production. The platform was originally designed for a security monitoring mission, but it has been enhanced to include important operational features desired by electrical utilities.

  12. Reconfigurable transmission lines with memcapacitive materials

    NASA Astrophysics Data System (ADS)

    Pershin, Y. V.; Slipko, V. A.; Di Ventra, M.

    2015-12-01

    We study transmission lines made of memory capacitive (memcapacitive) materials. The transmission properties of these lines can be adjusted on demand using an appropriate sequence of pulses. In particular, we demonstrate a pulse combination that creates a periodic modulation of dielectric properties along the line. Such a structure resembles a distributed Bragg reflector having important optical applications. We present simulation results demonstrating all major steps of such a reconfigurable device operation including reset, programming, and transmission of small amplitude signals. The proposed reconfigurable transmission lines employ only passive memory materials and can be realized using available memcapacitive devices.

  13. Detonator comprising a nonlinear transmission line

    SciTech Connect

    Elizondo-Decanini, Juan M

    2014-12-30

    Detonators are described herein. In a general embodiment, the detonator includes a nonlinear transmission line that has a variable capacitance. Capacitance of the nonlinear transmission line is a function of voltage on the nonlinear transmission line. The nonlinear transmission line receives a voltage pulse from a voltage source and compresses the voltage pulse to generate a trigger signal. Compressing the voltage pulse includes increasing amplitude of the voltage pulse and decreasing length of the voltage pulse in time. An igniter receives the trigger signal and detonates an explosive responsive to receipt of the trigger signal.

  14. 60-Hz electric-field effects on pineal melatonin rhythms: time course for onset and recovery

    SciTech Connect

    Wilson, B.W.; Chess, E.K.; Anderson, L.E.

    1986-01-01

    Rats exposed for 3 weeks to uniform 60-Hz electric fields of 39 kV/m (effective field strength) failed to show normal pineal gland circadian rhythms in serotonin N-acetyl transferase activity and melatonin concentrations. The time required for recovery of the melatonin rhythm after cessation of field exposure was determined to be less than 3 days. The rapid recovery suggests that the overall metabolic competence of the pineal is not permanently compromised by electric-field exposure, and that the circadian rhythm effect may be neuronally mediated.

  15. Diurnal patterns in brain biogenic amines of rats exposed to 60-Hz electric fields

    SciTech Connect

    Vasquez, B.J.; Anderson, L.E.; Lowery, C.I.; Adey, W.R.

    1988-01-01

    Levels of brain neurotransmitters and their metabolites, as well as concentrations of enzymes associated with their synthesis and metabolism, fluctuate during the day in patterns defined as circadian. The present study examined these rhythms in albino rats exposed to 60-Hz electric fields. Thirty-six animals were exposed to a 39 kV/m field for 4 weeks, 20 h/day, in a parallel-plate electrode system. A group of 36 sham animals was similarly handled and housed in a nonenergized exposure system. On the sampling day, animals were sacrificed at 4-h intervals throughout the 24-h day. Brains were removed, dissected, and kept frozen until chemically analyzed. The levels of biogenic amines and their acidic metabolites in the striatum, hypothalamus, and hippocampus were determined by high-performance liquid chromatography with electrochemical detection (HPLC-ECD) methods. Repeated exposure to 60-Hz electric fields produced significant alterations in the diurnal rhythms of several biogenic amines: dihydroxyphenylacetic acid (DOPAC, the primary metabolite of dopamine in the rat) in the striatum, and norepinephrine, dopamine, and 5-hydroxyindoleacetic acid (5-HIAA; serotonin metabolite) in the hypothalamus. Levels of serotonin in the striatum and hypothalamus showed clear circadian patterns that was not affected by the field. No diurnal or field-related changes were observed in the hippocampal amines.

  16. Effect of chronic 60-Hz electric field exposure on mammary tumorigenesis in the rat

    SciTech Connect

    Anderson, L.E.; Leung, F.C.; Rommereim, D.N.; Buschbom, R.L.; Wilson, B.W.; Stevens, R.G.

    1989-07-01

    Female rats were administered a single dosage of 7 or 10 mg of DMBA intragastrically between 50 and 55 days of age and palpated weekly for mammary tumors in two experiments. Rats were either exposed to a 40 kV/m 60-Hz electric field or sham-exposed in utero through 18 or 23 weeks of age. There was no difference between electric field exposed and sham-exposed in incidence of first tumor. When the results of the two experiments were combined, the electric field exposed groups had significantly more tumors per tumor-bearing animal than the sham-groups. These results may have implications for the role of electric power use in the etiology and promotion of breast cancer. 21 refs., 1 fig., 1 tab.

  17. Effects of a 60 Hz magnetic field on central cholinergic systems of the rat

    SciTech Connect

    Lai, H.; Carino, M.A.; Horita, A.; Guy, A.W. )

    1993-03-15

    The authors studied the effects of an acute exposure to a 60 Hz magnetic field on sodium-dependent, high-affinity choline uptake in the brain of the rat. Decreases in uptake were observed in the frontal cortex and hippocampus after the animals were exposed to a magnetic field at flux densities [>=] 0.75 mT. These effects of the magnetic field were blocked by pretreating the animals with the narcotic antagonist naltrexone, but not by the peripheral opioid antagonist, naloxone methiodide. These data indicate that the magnetic-field-induced decreases in high-affinity choline uptake in the rat brain were mediated by endogenous opioids in the central nervous systems.

  18. Single transmission line data acquisition system

    DOEpatents

    Fasching, George E.

    1984-01-01

    A single transmission line interrogated multiple channel data acquisition system is provided in which a plurality of remote station/sensors monitor specific process variables and transmit measurement values over the single transmission line to a master station when addressed by the master station. Power for all remote stations (up to 980) is provided by driving the line with constant voltage supplied from the master station and automatically maintained independent of the number of remote stations directly connected to the line. The transmission line can be an RG-62 coaxial cable with lengths up to about 10,000 feet with branches up to 500 feet. The remote stations can be attached randomly along the line. The remote stations can be scanned at rates up to 980 channels/second.

  19. Electrical Transmission Line Diametrical Retention Mechanism

    DOEpatents

    Hall, David R.; Hall, Jr., H. Tracy; Pixton, David; Dahlgren, Scott; Sneddon, Cameron; Briscoe, Michael; Fox, Joe

    2006-01-03

    The invention is a mechanism for retaining an electrical transmission line. In one embodiment of the invention it is a system for retaining an electrical transmission line within downhole components. The invention allows a transmission line to be attached to the internal diameter of drilling components that have a substantially uniform drilling diameter. In accordance with one aspect of the invention, the system includes a plurality of downhole components, such as sections of pipe in a drill string, drill collars, heavy weight drill pipe, and jars. The system also includes a coaxial cable running between the first and second end of a drill pipe, the coaxial cable having a conductive tube and a conductive core within it. The invention allows the electrical transmission line to withstand the tension and compression of drill pipe during routine drilling cycles.

  20. Investigation of effects of 60-Hz electric and magnetic fields on operant and social behavior and on the neuroendocrine system of nonhuman primates. Quarterly report 40, Operant behavior: Experiments 3, 4, and 4A

    SciTech Connect

    Rhodes, J.W.

    1992-09-24

    The objective of this program is to investigate behavioral and neuroendocrine effects associated with exposure to 60-Hz electric and magnetic fields (E/MF), using the baboon (Papio cynocephalus) as a nonhuman primate surrogate for the human. Results from this program, along with information from experiments conducted elsewhere, could be used to estimate and evaluate the likelihood of deleterious consequences of human exposure to the electric and magnetic fields associated with electric power transmission. This report covers a series of three experiments (Experiments III, IV, and IVA) on the effect of combined 60-Hz E/MF on operant behavior. These experiments were a continuation of previous investigations of 60-Hz electric field exposure on baboons.

  1. Transmission Line Series Compensation for Wind Energy Transmission

    NASA Astrophysics Data System (ADS)

    Palanichamy, Dr C., Prof; Wong, Y. C.

    2015-04-01

    Wind energy has demonstrated to be a clean, copious and absolutely renewable source of energy, and the large penetration of it into the power grid indicates that wind energy is considered an effective means of power generation, Transmission of wind energy from remote locations to load centers necessitates long transmission lines. Series compensation is a proven and economical transmission solution to address system power transfer strength, grid stability, and voltage profile issues of long transmission lines. In this paper, a programmable approach to determine the capacitive reactance of series capacitor and optimum location for its placement to achieve maximum power transfer gas been presented. The respective program with sample solutions has been provided for real-time applications.

  2. [Infantile leukemia and exposure to 50/60 Hz magnetic fields: review of epidemiologic evidence in 2000].

    PubMed

    Lagorio, S; Salvan, A

    2001-01-01

    We review the epidemiological evidence on childhood leukemia and residential exposure to 50/60 Hz magnetic fields. The possibility of carcinogenic effects of power frequency magnetic fields (ELF-EMF), at levels below units of micro tesla (microT), was first raised in 1979 by a case-control study on childhood cancer carried out in Denver, USA. In that study, excess risks of total cancer and leukemia were observed among children living in homes with "high or very high current configuration", as categorised on the basis of proximity to electric lines and transformers. Many other epidemiological studies have been published since then, characterised by improved--although still not optimal--methods of exposure assessment. At the end of 2000, the epidemiological evidence to support the association between exposure to extremely-low-frequency magnetic fields and the risk of childhood leukemia is less consistent than what was observed in the mid 90s. At the same time, a growing body of experimental evidence has accumulated against both a direct and a promoting carcinogenic effect of ELF-EMF. Such "negative" experimental evidence hampers a causal interpretation of the "positive" epidemiological studies. PMID:11758279

  3. Effect of 60 Hz electromagnetic fields on the activity of hsp70 promoter: an in vitro study.

    PubMed

    Rodríguez de la Fuente, Abraham O; Alcocer-González, Juan M; Antonio Heredia-Rojas, J; Balderas-Candanosa, Isaías; Rodríguez-Flores, Laura E; Rodríguez-Padilla, Cristina; Taméz-Guerra, Reyes S

    2009-03-01

    We have evaluated the effect of 60 Hz sinusoidal magnetic fields (MF) at 8 and 8 microT on expression of the luciferase gene contained in a gene construct labelled as Electromagnetic Field-plasmid (pEMF). The vector included the hsp70 promotor containing the 3 nCTCTn sequences previously described for the induction of hsp70 expression by magnetic fields, as well as the reporter of the luciferase gene. We also replicated the study of Lin et al. [Lin H, Blank M, Rossol-Haseroth K, Goodman R. Regulating genes with electromagnetic response elements. J Cell Biochem 2001;81(1):143-48]. The pEMF plasmid was transfected into HeLa and BMK16 cell lines that were later exposed to either MF or thermal shock (TS). An increased luciferase expression was found in both the cells exposed to MF and TS compared with their control groups (P < 0.05). Furthermore, the combined effect of MF and TS was also analyzed. A synergistic effect between two factors was observed for this co-exposure condition in terms of luciferase gene expression. PMID:18957326

  4. Biological studies of swine exposed to 60-Hz electric fields. Volume 1. Overview and summary. Final report

    SciTech Connect

    Not Available

    1985-12-01

    Over a three-year period, three generations of female miniature swine and their offspring were exposed to a 30-kV/m, 60-Hz electric field. Such a field approximates the 12-kV/m field that a human would experience under a 765-kV line. After swine exposures varying from 6 to 36 months, project personnel analyzed a wide range of biological parameters including growth, blood cell and serum biochemistry, blood immunoglobulin levels, behavior, peripheral nerve function, cell-mediated immunity, cytogenetics, and reproduction and development. There were no significant differences in health effects between the exposed and sham-exposed swine, except in the area of fetal development. The first breeding produced no significant difference between exposed and control offspring. When those offspring were bred after 18 months of exposure, the fetuses of exposed sows had an increased incidence of morphological malformations and lower body weight than fetuses from control sows. The live-born had lower body weights and increased birth defects. Several factors suggest that electric fields per se may not have caused these reproductive changes. For example, similar types of malformations occurred in control pigs. Also, in second-generation sows, the incidence of fetal malformations was similar for both exposed and control groups. It is possible that other factors such as housing, inbreeding, disease, or treatment of disease may have produced the observed effects. 64 refs., 13 figs., 25 tabs.

  5. Effect of tornado loads on transmission lines

    SciTech Connect

    Ishac, M.F.; White, H.B.

    1995-01-01

    Of all the populated areas in Canada, southwestern Ontario has experienced the highest tornado incidence and faces the greatest tornado damage. About 1 or 2 tornadoes per 10,000 km{sup 2} can be expected there annually. The probability of a tornado strike at a given point is very small but the probability of a transmission line being crossed by a tornado is significant. The purpose of this paper is to review the literature related to tornadoes in Ontario and to investigate the effect of tornado loads on transmission lines. Based on this investigation a design basis tornado loading for transmission towers is proposed.

  6. Effect of tornado loads on transmission lines

    SciTech Connect

    Ishac, M.F.; White, H.B.

    1994-12-31

    Of all the populated areas in Canada, southwestern Ontario has experienced the highest tornado incidence and faces the greatest tornado damage. About 1 or 2 tornadoes per 10,000 km{sup 2} can be expected there annually. The probability of a tornado strike at a given point is very small but the probability of a transmission line being crossed by a tornado is significant. The purpose of this paper is to review the literature related to tornadoes in Ontario and to investigate the effect of tornado loads on transmission lines. Based on this investigation a design basis tornado loading for transmission towers is proposed.

  7. Concurrent Wind Cooling in Power Transmission Lines

    SciTech Connect

    Jake P Gentle

    2012-08-01

    Idaho National Laboratory and the Idaho Power Company, with collaboration from Idaho State University, have been working on a project to monitor wind and other environmental data parameters along certain electrical transmission corridors. The combination of both real-time historical weather and environmental data is being used to model, validate, and recommend possibilities for dynamic operations of the transmission lines for power and energy carrying capacity. The planned results can also be used to influence decisions about proposed design criteria for or upgrades to certain sections of the transmission lines.

  8. Load-resistant coaxial transmission line

    DOEpatents

    Hall, David R.; Fox, Joe

    2006-01-03

    A transmission line for downhole tools that make up all or part of a tool string for drilling and production of oil, gas, and geothermal wells that can withstand the dynamic gravitational forces and other accelerations associated with downhole excavations. The transmission line has a metal tube, or outer conductor, that houses a coaxial wire inner conductor. A non-metallic dielectric material is interposed between the inner and outer conductors. The outer and inner conductors and the dielectric are sufficiently compressed together so that independent motion between them is abated. Compression of the components of the transmission line may be achieved by drawing the transmission through one or more dies in order to draw down the outer conductor onto the dielectric, or by expanding the inner conductor against the dielectric using a mandrel or hydraulic pressure. Non-metallic bead segments may be used in aid of the compression necessary to resist the dynamic forces and accelerations of drilling.

  9. Bird streamer flashovers on FPL transmission lines

    SciTech Connect

    Burnham, J.T.

    1995-04-01

    FPL transmission lines with excessive unknown cause outages were investigated and determined to have experiences bird streamer flashovers. Findings are extended to similar lines and the frequency of bird streamer occurrences are estimated. Outage patterns associated with bird streamer flashovers are presented.

  10. Upgrading a 24-in. gas transmission line

    SciTech Connect

    Stiles, R.E.

    1986-10-01

    Because of increasing population density, Texas Eastern Transmission Corp. removed an existing 24-in. gas line and replaced it with a higher yield line pipe with a greater wall thickness. Work was through exclusive lake subdivisions and across a golf course and required special construction techniques.

  11. Comparison of the coupling of grounded and ungrounded humans to vertical 60-Hz electric fields

    SciTech Connect

    Kaune, W.T.; Kistler, L.M.; Miller, M.C.

    1985-12-01

    Total induced currents and average induced axial current densities have been published in the literature for human models exposed to 60-Hz electric fields. The results of these studies have been quite useful, but they deal with a somewhat idealized exposure situation that ignores the insulating effects of most types of footwear. This paper describes a new laboratory technique for studying the relationship between grounded and ungrounded exposure of humans. A conducting model of the body 40-cm-tall man was electrically divided into seven segments. Wires connected to the conducting surfaces of these segments were routed horizontally through shielded cable to remote, battery-powered electronics. The ''common'' potential of the electronics was biased to the electric-field-induced potential of the model, allowing us to accurately measure the current induced in each body segment of the model. The method was tested by measuring the current induced in the upper hemisphere of a ungrounded sphere: agreement between theory and measurement was excellent. Measurements were made with the human model located at 15 positions, ranging from touching ground to remote from ground (i.e., in free space). The ratios of free-space to grounded currents crossing horizontal sections through the body were: neck, 0.58; chest, 0.40; abdomen, 0.39; thigh, 0.36; ankle, 0.17.

  12. Deficits in high- (>60 Hz) gamma-band oscillations during visual processing in schizophrenia

    PubMed Central

    Grützner, Christine; Wibral, Michael; Sun, Limin; Rivolta, Davide; Singer, Wolf; Maurer, Konrad; Uhlhaas, Peter J.

    2013-01-01

    Current theories of the pathophysiology of schizophrenia have focused on abnormal temporal coordination of neural activity. Oscillations in the gamma-band range (>25 Hz) are of particular interest as they establish synchronization with great precision in local cortical networks. However, the contribution of high gamma (>60 Hz) oscillations toward the pathophysiology is less established. To address this issue, we recorded magnetoencephalographic (MEG) data from 16 medicated patients with chronic schizophrenia and 16 controls during the perception of Mooney faces. MEG data were analysed in the 25–150 Hz frequency range. Patients showed elevated reaction times and reduced detection rates during the perception of upright Mooney faces while responses to inverted stimuli were intact. Impaired processing of Mooney faces in schizophrenia patients was accompanied by a pronounced reduction in spectral power between 60–120 Hz (effect size: d = 1.26) which was correlated with disorganized symptoms (r = −0.72). Our findings demonstrate that deficits in high gamma-band oscillations as measured by MEG are a sensitive marker for aberrant cortical functioning in schizophrenia, suggesting an important aspect of the pathophysiology of the disorder. PMID:23532620

  13. Nonhuman primates will not respond to turn off strong 60 Hz electric fields

    SciTech Connect

    Rogers, W.R.; Orr, J.L.; Smith, H.D.

    1995-12-31

    Using a set of six baboons (Papio cynocephalus), the authors conducted a series of seven experiments designed to evaluate the potentially aversive character of a 60 Hz electric field (EF). Initially, the subjects were trained, using food rewards as the reinforcer, to respond only when a cue light was illuminated. Next, an EF was presented along with the cue light; responses produced delivery of a food pellet and turned off both the cue light and the EF. Then, stimulus and reward conditions were varied. The authors determined that (1) presence of a strong EF does not affect operant responding for food rewards, (2) subjects will not respond at normal rates when the only reinforcer is termination of a strong EF, (3) presence of a strong EF can serve as a discriminative stimulus, (4) presence of a strong EF does not affect extinction of an appetite-motivated task, and (5) presentation of an EF can become a secondary reinforcer. The pattern of results was consistent across all experiments, suggesting that an EF of as much as 65 kV/m is not aversive to nonhuman primates. Separately, the authors demonstrated that the average EF detection threshold for baboons is 12 kV/m. Thus, EF exposure at intensities well above the detection threshold and at species-scaled EF strengths greater than those found environmentally does not appear to be aversive.

  14. Biological effects of 60-Hz electric fields on small and large laboratory animals

    SciTech Connect

    Phillips, R.D.

    1981-01-01

    Rats and mice were exposed to 60-Hz electric fields up to 330 kV/m for durations as long as four months. No significant effects were found in the following major areas: metabolic status and growth; organ and tissue morphology; brain morphology; cardiovascular function; serum chemistry; reproduction; prenatal growth and development; teratology; bone growth; peripheral nerve function; humoral and cell-mediated immunity; susceptibility to viral infection; cell and membrane function; illness/malaise; and cytogenetics. Statistically significant effects of electric field exposures were observed in the following areas: bone fracture repair; neonatal development; neuromuscular function; endocrinology; hematology; neurochemistry; urine volume and chemistry; sympathetic nervous system; behavior. It is likely that many of the effects observed are secondary to chronic stimulation of the animal by the field. Our research efforts have shifted to an in-depth investigation of nervous system functions, with emphasis in behavior, neurochemistry, neurophysiology, and dosimetry. Current and future research in these areas will focus on: relationship of effects to field strength and duration of exposure; recovery from observed effects; fundamental understanding of observed effects; fundamental understanding of interaction of field with animal (dosimetry); and biological significance of observed effects. (ERB)

  15. Effects of 60-Hz electric fields on serotonin metabolism in the rat pineal gland

    SciTech Connect

    Anderson, L.E.; Hilton, D.I.; Phillips, R.D.; Wilson, B.W.; Chess, E.K.

    1982-06-01

    Serotonin and two of its metabolites, melatonin and 5-methoxytryptophol, exhibit circadian rhythmicity in the pineal gland. We recently reported a marked reduction in the normal night-time increase in melatonin concentration in the pineal glands of rats exposed to 60-Hz electric fields. Concomitant with the apparent abolition of melatonin rhythmicity, serotonin-N-acetyl transferase (SNAT) activity was suppressed. We have now conducted studies to determine if abolition of the rhythm in melatonin production in electric-field-exposed rats arises solely from interference in SNAT activity, or if the availability of pineal serotonin is a factor that is affected by exposure. Pineal serotonin concentrations were compared in rats that were either exposed or sham exposed to 65 kV/m for 30 days. Sham-exposed animals exhibited normal diurnal rhythmicity for pineal concentrations of both melatonin and serotonin; melatonin levels increased markedly during the dark phase with a concurrent decrease in serotonin levels. In the exposed animals, however, normal serotonin rhythmicity was abolished; serotonin levels in these animals did not increase during the light period. The conclusion that electric field exposure results in a biochemical alteration in SNAT enzyme activity can be inferred from the loss of both serotonin and melatonin rhythmicity, as well as by direct measurement of SNAT activity itself. 35 references, 3 figures, 1 table.

  16. Numerical calculation and measurement of 60-Hz current densities induced in an upright grounded cylinder.

    PubMed

    Kaune, W T; McCreary, F A

    1985-01-01

    Power-frequency electric fields are strongly perturbed in the vicinity of human beings and experimental animals. As a consequence, the extrapolation of biological data from laboratory animals to human-exposure situations cannot use the unperturbed exposure field strength as a common exposure parameter. Rather, comparisons between species must be based on the actual electric fields at the outer surfaces of and inside the bodies of the subjects. Experimental data have been published on surface and internal fields for a few exposure situations, but it is not feasible to characterize experimentally more than a small fraction of the diverse types of exposures which occur in the laboratory and in the field. A predictive numerical model is needed, one whose predictions have been verified in situations where experimental data are available, and one whose results can be used with confidence in new exposure situations. This paper describes a numerical technique which can be used to develop such a model, and it carries out this development for a test case, that of a homogeneous right-circular cylinder resting upright on-end on a ground plane and exposed to a vertical, uniform, 60-Hz electric field. The accuracy of the model is tested by comparing short-circuit currents and induced current densities predicted by it to measured values: Agreement is good. PMID:3836665

  17. Rodent cell transformation and immediate early gene expression following 60-Hz magnetic field exposure.

    PubMed Central

    Balcer-Kubiczek, E K; Zhang, X F; Harrison, G H; McCready, W A; Shi, Z M; Han, L H; Abraham, J M; Ampey, L L; Meltzer, S J; Jacobs, M C; Davis, C C

    1996-01-01

    Some epidemiological studies suggest that exposure to power frequency magnetic fields (MFs) may be associated with an elevated risk of human cancer, but the experimental database remains limited and controversial. We investigated the hypothesis that 60-Hz MF action at the cellular level produces changes in gene expression that can result in neoplastic transformation. Twenty-four hour 200 microT continuous MF exposure produced negative results in two standard transformation systems (Syrian hamster embryo cells and C3H/10T1/2 murine fibroblasts) with or without postexposure to a chemical promoter. This prompted a reexamination of previously reported MF-induced changes in gene expression in human HL60 cells. Extensive testing using both coded and uncoded analyses was negative for an MF effect. Using the same exposure conditions as in the transformation studies, no MF-induced changes in ornithine decarboxylase expression were observed in C3H/10T1/2 cells, casting doubt on a promotional role of MF for the tested cells and experimental conditions. Images Figure 1. Figure 2. A Figure 2. B Figure 2. C Figure 2. D Figure 3. A Figure 3. B Figure 4. Figure 5. A Figure 5. B Figure 5. C Figure 5. D Figure 5. E Figure 6. A Figure 6. B Figure 6. C Figure 6. D Figure 6. E Figure 7. Figure 8. A Figure 8. B Figure 8. C Figure 9. Figure 10. A Figure 10. B PMID:8959408

  18. Low-noise cryogenic transmission line

    NASA Technical Reports Server (NTRS)

    Norris, D.

    1987-01-01

    New low-noise cryogenic input transmission lines have been developed for the Deep Space Network (DSN) at 1.668 GHz for cryogenically cooled Field Effect Transistors (FET) and High Electron Mobility Transistor (HEMT) amplifiers. These amplifiers exhibit very low noise temperatures of 5 K to 15 K, making the requirements for a low-noise input transmission line critical. Noise contribution to the total amplifier system from the low-noise line is less than 0.5 K for both the 1.668-GHz and 2.25-GHz FET systems. The 1.668-GHz input line was installed in six FET systems which were implemented in the DSN for the Venus Balloon Experiment. The 2.25-GHz input line has been implemented in three FET systems for the DSN 34-m HEF antennas, and the design is currently being considered for use at higher frequencies.

  19. Evaluation of the developmental toxicity of 60 Hz magnetic fields and harmonic frequencies in Sprague-Dawley rats.

    PubMed

    Ryan, B M; Polen, M; Gauger, J R; Mallett, E; Kearns, M B; Bryan, T L; McCormick, D L

    2000-05-01

    Experimental data suggest that exposure to the 50 and 60 Hz sinusoidal components of power-frequency magnetic fields (MFs) does not have an adverse impact on fetal development. However, the possible developmental toxicity of MF harmonics has not been investigated. This study was designed to determine whether exposure to 180 Hz MFs (third harmonic), alone or in combination with 60 Hz MFs, induces birth defects in Sprague-Dawley rats. Groups of sperm-positive dams (> or =20/group) were exposed for 18.5 h per day from gestation days 6 through 19 to (1) ambient MFs only (<0.0001 mT; sham controls); (2) 60 Hz MFs at 0.2 mT; (3) 180 Hz MFs at 0.2 mT; or (4) 60 Hz + 180 Hz MFs (10% third harmonic; total field strength = 0.2 mT). Litter size, litter weight, percentage live births, sex ratio, and number of resorption sites were determined for each dam, and gross external, visceral, cephalic and skeletal examinations were performed on all fetuses. MF exposure had no significant effects on litter size, litter weight, or fetal development. With the exception of common rib variants, the incidence of fetal anomalies was comparable in all groups. A small increase in the incidence of rib variants was seen in the group exposed to 60 Hz + 180 Hz MFs; however, the incidence of rib variants in this group was similar to that in historical controls from our laboratory. These data extend the existing database on developmental toxicity of MFs by demonstrating that exposure to 180 Hz MFs, either alone or superimposed on an underlying 60 Hz signal, does not induce biologically significant developmental toxicity. These data do not support the hypothesis that exposure to power-frequency MFs is an important risk factor for fetal development. PMID:10790286

  20. Lecture 4: transmission lines and capacitors

    SciTech Connect

    Butcher, R.R.

    1980-01-01

    The topic of this lecture is pulse forming networks. The first item of discussion will be transmission lines because they are so prevalent, even if only in the form of coaxial cable. From there the subject will proceed to pulse-forming networks: the practical problems encountered with them, their advantages, and disadvantages. Capacitors will be our final topic, as they are the limiting factor in lumped transmission elements.

  1. Robust hyperchaotic synchronization via analog transmission line

    NASA Astrophysics Data System (ADS)

    Sadoudi, S.; Tanougast, C.

    2016-02-01

    In this paper, a novel experimental chaotic synchronization technique via analog transmission is discussed. We demonstrate through Field-Programmable Gate Array (FPGA) implementation design the robust synchronization of two embedded hyperchaotic Lorenz generators interconnected with an analog transmission line. The basic idea of this work consists in combining a numerical generation of chaos and transmitting it with an analog signal. The numerical chaos allows to overcome the callback parameter mismatch problem and the analog transmission offers robust data security. As application, this technique can be applied to all families of chaotic systems including time-delayed chaotic systems.

  2. Flux Cloning in Josephson Transmission Lines

    SciTech Connect

    Gulevich, D.R.; Kusmartsev, F.V.

    2006-07-07

    We describe a novel effect related to the controlled birth of a single Josephson vortex. In this phenomenon, the vortex is created in a Josephson transmission line at a T-shaped junction. The 'baby' vortex arises at the moment when a 'mother' vortex propagating in the adjacent transmission line passes the T-shaped junction. In order to give birth to a new vortex, the mother vortex must have enough kinetic energy. Its motion can also be supported by an externally applied driving current. We determine the critical velocity and the critical driving current for the creation of the baby vortices and briefly discuss the potential applications of the found effect.

  3. EC Transmission Line Risk Identification and Analysis

    SciTech Connect

    Bigelow, Tim S

    2012-04-01

    The purpose of this document is to assist in evaluating and planning for the cost, schedule, and technical project risks associated with the delivery and operation of the EC (Electron cyclotron) transmission line system. In general, the major risks that are anticipated to be encountered during the project delivery phase associated with the implementation of the Procurement Arrangement for the EC transmission line system are associated with: (1) Undefined or changing requirements (e.g., functional or regulatory requirements) (2) Underperformance of prototype, first unit, or production components during testing (3) Unavailability of qualified vendors for critical components Technical risks associated with the design and operation of the system are also identified.

  4. Effect of 60 Hz magnetic fields on the activation of hsp70 promoter in cultured INER-37 and RMA E7 cells.

    PubMed

    Heredia-Rojas, J Antonio; Rodríguez de la Fuente, Abraham Octavio; Alcocer González, Juan Manuel; Rodríguez-Flores, Laura E; Rodríguez-Padilla, Cristina; Santoyo-Stephano, Martha A; Castañeda-Garza, Esperanza; Taméz-Guerra, Reyes S

    2010-10-01

    It has been reported that 50-60 Hz magnetic fields (MF) with flux densities ranging from microtesla to millitesla are able to induce heat shock factor or heat shock proteins in various cells. In this study, we investigated the effect of 60 Hz sinusoidal MF at 8 and 80 μT on the expression of the luciferase gene contained in a plasmid labeled as electromagnetic field-plasmid (pEMF). This gene construct contains the specific sequences previously described for the induction of hsp70 expression by MF, as well as the reporter for the luciferase gene. The pEMF vector was transfected into INER-37 and RMA E7 cell lines that were later exposed to either MF or thermal shock (TS). Cells that received the MF or TS treatments and their controls were processed according to the luciferase assay system for evaluate luciferase activity. An increased luciferase gene expression was observed in INER-37 cells exposed to MF and TS compared with controls (p < 0.05), but MF exposure had no effect on the RMA E7 cell line. PMID:20835776

  5. Investigation of effects of 60-Hz electric and magnetic fields on operant and social behavior and on the neuroendocrine system of nonhuman primates

    SciTech Connect

    Orr, J.L.

    1989-10-01

    The objective of this program is to investigate, using the baboon as a nonhuman primate surrogate for the human, behavioral and neuroendocrine effects associated with exposure to 60-Hz electric and magnetic fields. Results from this program could be used to estimate and evaluate the likelihood of deleterious consequences resulting from exposure of humans to the electric and magnetic fields associated with electric power transmission. This program is being conducted at Southwest Research Institute (SwRI) as part of an international collaborative information exchange and scientific research effort. This annual report marks the completion of the first year of the four year research program. This project year has focused on two technical areas: the modification of the facility to include 60-Hz magnetic fields, and development of the capability for studies of neuroendocrine parameters by obtaining blood samples from baboons during electric and magnetic field exposure. Activities in the social behavior, operant behavior, and laboratory animal sciences during this project year have been in preparation for the start of Experiment 3. 7 figs., 10 tabs.

  6. 49 CFR 192.706 - Transmission lines: Leakage surveys.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Transmission lines: Leakage surveys. 192.706... Transmission lines: Leakage surveys. Leakage surveys of a transmission line must be conducted at intervals not exceeding 15 months, but at least once each calendar year. However, in the case of a transmission line...

  7. 49 CFR 192.706 - Transmission lines: Leakage surveys.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Transmission lines: Leakage surveys. 192.706... Transmission lines: Leakage surveys. Leakage surveys of a transmission line must be conducted at intervals not exceeding 15 months, but at least once each calendar year. However, in the case of a transmission line...

  8. 49 CFR 192.706 - Transmission lines: Leakage surveys.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Transmission lines: Leakage surveys. 192.706... Transmission lines: Leakage surveys. Leakage surveys of a transmission line must be conducted at intervals not exceeding 15 months, but at least once each calendar year. However, in the case of a transmission line...

  9. 49 CFR 192.706 - Transmission lines: Leakage surveys.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Transmission lines: Leakage surveys. 192.706... Transmission lines: Leakage surveys. Leakage surveys of a transmission line must be conducted at intervals not exceeding 15 months, but at least once each calendar year. However, in the case of a transmission line...

  10. 49 CFR 192.706 - Transmission lines: Leakage surveys.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Transmission lines: Leakage surveys. 192.706... Transmission lines: Leakage surveys. Leakage surveys of a transmission line must be conducted at intervals not exceeding 15 months, but at least once each calendar year. However, in the case of a transmission line...

  11. Coaxial tube array space transmission line characterization

    NASA Technical Reports Server (NTRS)

    Switzer, Colleen A.; Bents, David J.

    1987-01-01

    The coaxial tube array tether/transmission line used to connect an SP-100 nuclear power system to the space station was characterized over the range of reactor-to-platform separation distances of 1 to 10 km. Characterization was done with respect to array performance, physical dimensions and masses. Using a fixed design procedure, a family of designs was generated for the same power level (300 kWe), power loss (1.5 percent), and meteoroid survival probability (99.5 percent over 10 yr). To differentiate between vacuum insulated and gas insulated lines, two different maximum values of the E field were considered: 20 kV/cm (appropriate to vacuum insulation) and 50 kV/cm (compressed SF6). Core conductor, tube, bumper, standoff, spacer and bumper support dimensions, and masses were also calculated. The results of the characterization show mainly how transmission line size and mass scale with reactor-to-platform separation distance.

  12. Coaxial tube array space transmission line characterization

    NASA Astrophysics Data System (ADS)

    Switzer, Colleen A.; Bents, David J.

    The coaxial tube array tether/transmission line used to connect an SP-100 nuclear power system to the space station was characterized over the range of reactor-to-platform separation distances of 1 to 10 km. Characterization was done with respect to array performance, physical dimensions and masses. Using a fixed design procedure, a family of designs was generated for the same power level (300 kWe), power loss (1.5 percent), and meteoroid survival probability (99.5 percent over 10 yr). To differentiate between vacuum insulated and gas insulated lines, two different maximum values of the E field were considered: 20 kV/cm (appropriate to vacuum insulation) and 50 kV/cm (compressed SF6). Core conductor, tube, bumper, standoff, spacer and bumper support dimensions, and masses were also calculated. The results of the characterization show mainly how transmission line size and mass scale with reactor-to-platform separation distance.

  13. Transmission line environmental assessment guidance document

    SciTech Connect

    Jackson, J.; Pentecost, E.; Muzzarelli, J.

    1994-01-01

    Since 1939, U.S. utility companies have been required to obtain a Presidential Permit to construct electric transmission lines that cross a U.S. border and connect with a foreign utility. The purpose of this document is to provide Presidential Permit applicants with two types of guidance: (1) on the type of environmental and project descriptive information needed to assess the potential impacts of the proposed and alternative actions and (2) on compliance with applicable federal and state regulations. The main three chapters present information on the purpose and content of this document (Chapter 1); legislative, regulatory, and consultation requirements for transmission line interconnect projects (Chapter 2); and identification of basic transmission system design parameters and environmental data requirements for analysis of potential impacts of the proposed action (Chapter 3). Chapter 3 also includes information on possible techniques or measures to mitigate impacts. Appendix A presents an overview of NEPA requirements and DOE`s implementing procedures. Appendix B summarizes information on legislation that may be applicable to transmission line projects proposed in Presidential Permit applications.

  14. Integrated survey and design for transmission lines

    SciTech Connect

    Miller, M.A.; Simpson, K.D.

    1994-12-31

    Gathering and compiling information on the features and uses of the land within a proposed corridor provides the basis for selecting a route, obtaining easements, and designing and constructing a transmission line. Traditionally, gathering this information involved searches of existing maps and records to obtain the available information, which would then be supplemented with aerial photography to record current conditions. Ground surveys were performed to collect topographic data for design purposes. This information was manually transferred to drawings and other documents to show the terrain, environmentally sensitive areas, property ownership, and existing facilities. These drawing served as the base to which the transmission line right-of-way, structures, and other design information were added. As the design was completed, these drawings became the source of information for constructing the line and ultimately, the record of the facility. New technologies and the every growing need for instantly accessible information have resulted in changes in almost every step of gathering, storing and using information. Electronic data collection, global positioning systems (GPS), digitized terrain models, computerized design techniques, development of drawings using CAD, and graphical information systems (GIS) have individually resulted in significant advancements in this process. Combining these components into an integrated system, however, is truly revolutionizing transmission line engineering. This paper gives an overview of the survey and mapping information that is required for transmission line projects, review the traditional techniques that have been employed to obtain and utilize this information, and discuss the recent advances in the technology. Additionally, a system is presented that integrates the components in this process to achieve efficiency, minimize chances of errors, and provide improved access to project information.

  15. Electric field of the power terrestrial sources observed by microsatellite Chibis-M in the Earth's ionosphere in frequency range 1-60 Hz

    NASA Astrophysics Data System (ADS)

    Dudkin, Fedir; Korepanov, Valery; Dudkin, Denis; Pilipenko, Vyacheslav; Pronenko, Vira; Klimov, Stanislav

    2015-07-01

    The power line emission (PLE) 50/60 Hz and the Schumann resonance (SR) harmonics were detected by the use of a compact electrical field sensor of length 0.42 m during microsatellite Chibis-M mission in years 2012-2014. The initial orbit of Chibis-M has altitude 500 km and inclination 52°. We present the space distribution of PLE and its connections with the possible overhead power lines. PLE has been recorded both in the shade and sunlit parts of the orbits as opposed to SR which have been recorded only in the nightside of the Earth. The cases of an extra long distance of PLE propagation in the Earth's ionosphere and increased value of SR Q factor have been also observed. These results should stimulate the ionosphere model refinement for ultralow frequency and extremely low frequency electromagnetic wave propagation as well as a study on new possibility of the ionosphere diagnostics.

  16. 7 CFR 1726.77 - Substation and transmission line construction.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 11 2012-01-01 2012-01-01 false Substation and transmission line construction. 1726... and Transmission Facilities § 1726.77 Substation and transmission line construction. (a) Contract... substation and transmission line construction (including minor modifications or improvements), exclusive...

  17. 7 CFR 1726.77 - Substation and transmission line construction.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 11 2011-01-01 2011-01-01 false Substation and transmission line construction. 1726... and Transmission Facilities § 1726.77 Substation and transmission line construction. (a) Contract... substation and transmission line construction (including minor modifications or improvements), exclusive...

  18. 7 CFR 1726.77 - Substation and transmission line construction.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 11 2010-01-01 2010-01-01 false Substation and transmission line construction. 1726... and Transmission Facilities § 1726.77 Substation and transmission line construction. (a) Contract... substation and transmission line construction (including minor modifications or improvements), exclusive...

  19. 7 CFR 1726.77 - Substation and transmission line construction.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 11 2014-01-01 2014-01-01 false Substation and transmission line construction. 1726... and Transmission Facilities § 1726.77 Substation and transmission line construction. (a) Contract... substation and transmission line construction (including minor modifications or improvements), exclusive...

  20. 7 CFR 1726.77 - Substation and transmission line construction.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 11 2013-01-01 2013-01-01 false Substation and transmission line construction. 1726... and Transmission Facilities § 1726.77 Substation and transmission line construction. (a) Contract... substation and transmission line construction (including minor modifications or improvements), exclusive...

  1. Application of composite insulators to transmission lines

    SciTech Connect

    Cherney, E.A.; Brown, R.L.; Karady, G.; Nicholls, J.L.; Orbeck, T.; Pargamin, L.

    1983-05-01

    The paper provides guidelines for the application of composite insulators to transmission lines. These guidelines are based on utility field experiences, results of research laboratory tests and manufacturers' recommendations. Discussed are interchangeability with porcelain and glass insulators, application in contaminated environments, material ageing, insulator icing, the use of grease, resistance to vandalism, temperature extremes, and the need for grading rings. Clarification is provided on the mechanical rating of composite insulators because there is not yet general agreement by various industry groups.

  2. (Investigation of effects of 60-Hz electric and magnetic fields on operant and social behavior and on the neuroendocrine system of nonhuman primates)

    SciTech Connect

    Orr, J.L.

    1989-03-24

    The objective of this program is to investigate, using the baboon as a nonhuman primate surrogate for the human, behavioral and neuroendocrine effects associated with exposure to 60-Hz electric and magnetic fields. Results from this program, along with information from experiments conducted elsewhere, could be used to estimate and evaluate the likelihood of deleterious consequences resulting from exposure of humans to the electric and magnetic fields associated with electric power transmission. The test facility is being modified to include combined electric and magnetic field capability. This will be accomplished by the installation of a magnetic field exposure system and modification of the electric field exposure equipment. The purpose of this document is to provide information on the design. 14 figs., 5 tabs.

  3. Dispersion-free radial transmission lines

    DOEpatents

    Caporaso, George J.; Nelson, Scott D.

    2011-04-12

    A dispersion-free radial transmission line ("DFRTL") preferably for linear accelerators, having two plane conductors each with a central hole, and an electromagnetically permeable material ("EPM") between the two conductors and surrounding a channel connecting the two holes. At least one of the material parameters of relative magnetic permeability, relative dielectric permittivity, and axial width of the EPM is varied as a function of radius, so that the characteristic impedance of the DFRTL is held substantially constant, and pulse transmission therethrough is substantially dispersion-free. Preferably, the EPM is divided into concentric radial sections, with the varied material parameters held constant in each respective section but stepwise varied between sections as a step function of the radius. The radial widths of the concentric sections are selected so that pulse traversal time across each section is the same, and the varied material parameters of the concentric sections are selected to minimize traversal error.

  4. View facing north, Structure 162 in foreground, as Transmission Line ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View facing north, Structure 16-2 in foreground, as Transmission Line turns at intersection of Powerline Road and US 87 - Havre Rainbow Transmission Line, Havre City to Great Falls vicinity, Montana, Great Falls, Cascade County, MT

  5. 3. DETAIL, LIGHTNING ARRESTER ON SAR TRANSMISSION LINE. EEC print ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    3. DETAIL, LIGHTNING ARRESTER ON SAR TRANSMISSION LINE. EEC print no. S-C-01-00478, no date. Photographer unknown. - Santa Ana River Hydroelectric System, Transmission Lines, Redlands, San Bernardino County, CA

  6. View facing south, near Structure 515, of Transmission Line rising ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View facing south, near Structure 51-5, of Transmission Line rising out of Marias River Valley - Havre Rainbow Transmission Line, Havre City to Great Falls vicinity, Montana, Great Falls, Cascade County, MT

  7. Transmission line icing measurement on photogrammetry method

    NASA Astrophysics Data System (ADS)

    Huang, Huan; Ma, Xiaohong; Zhao, Lijin; Du, Hao; Luo, Hong; Mao, Xianyin; Tang, Min; Liu, Yawen

    2015-12-01

    Icing thickness parameter is the basic data for power sector to make decision for icing accident prevention. In this paper, a transmission line icing measurement method is proposed. It used the photogrammetry method to realize icing parameters measurement through the integration of high resolution camera, laser range finder and inertial measurement unit. Compared with traditional icing measurement method, this method is flexible and is the effective supplement of the fixed icing detection terminal. And its high accuracy measurement guarantees the reliability of the icing thickness parameters.

  8. Transmission line including support means with barriers

    DOEpatents

    Cookson, Alan H.

    1982-01-01

    A gas insulated transmission line includes an elongated outer sheath, a plurality of inner conductors disposed within and extending along the outer sheath, and an insulating gas which electrically insulates the inner conductors from the outer sheath. A support insulator insulatably supports the inner conductors within the outer sheath, with the support insulator comprising a main body portion including a plurality of legs extending to the outer sheath, and barrier portions which extend between the legs. The barrier portions have openings therein adjacent the main body portion through which the inner conductors extend.

  9. Giant vacuum forces via transmission lines

    PubMed Central

    Shahmoon, Ephraim; Mazets, Igor; Kurizki, Gershon

    2014-01-01

    Quantum electromagnetic fluctuations induce forces between neutral particles, known as the van der Waals and Casimir interactions. These fundamental forces, mediated by virtual photons from the vacuum, play an important role in basic physics and chemistry and in emerging technologies involving, e.g., microelectromechanical systems or quantum information processing. Here we show that these interactions can be enhanced by many orders of magnitude upon changing the character of the mediating vacuum modes. By considering two polarizable particles in the vicinity of any standard electric transmission line, along which photons can propagate in one dimension, we find a much stronger and longer-range interaction than in free space. This enhancement may have profound implications on many-particle and bulk systems and impact the quantum technologies mentioned above. The predicted giant vacuum force is estimated to be measurable in a coplanar waveguide line. PMID:25002503

  10. 49 CFR 192.745 - Valve maintenance: Transmission lines.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Valve maintenance: Transmission lines. 192.745 Section 192.745 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND... maintenance: Transmission lines. (a) Each transmission line valve that might be required during any...

  11. 49 CFR 192.179 - Transmission line valves.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Transmission line valves. 192.179 Section 192.179... BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Design of Pipeline Components § 192.179 Transmission line valves. (a) Each transmission line, other than offshore segments, must have sectionalizing...

  12. 49 CFR 192.179 - Transmission line valves.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Transmission line valves. 192.179 Section 192.179... BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Design of Pipeline Components § 192.179 Transmission line valves. (a) Each transmission line, other than offshore segments, must have sectionalizing...

  13. 32 CFR 644.431 - Power transmission lines.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 32 National Defense 4 2012-07-01 2011-07-01 true Power transmission lines. 644.431 Section 644.431... transmission lines. (a) Authority. Pursuant to the provisions of section 13(d) of the Surplus Property Act of... transmission line and the right of way acquired for its construction is needed for or adaptable to...

  14. 49 CFR 192.179 - Transmission line valves.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Transmission line valves. 192.179 Section 192.179... BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Design of Pipeline Components § 192.179 Transmission line valves. (a) Each transmission line, other than offshore segments, must have sectionalizing...

  15. 32 CFR 644.431 - Power transmission lines.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 32 National Defense 4 2014-07-01 2013-07-01 true Power transmission lines. 644.431 Section 644.431... transmission lines. (a) Authority. Pursuant to the provisions of section 13(d) of the Surplus Property Act of... transmission line and the right of way acquired for its construction is needed for or adaptable to...

  16. 49 CFR 192.745 - Valve maintenance: Transmission lines.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Valve maintenance: Transmission lines. 192.745 Section 192.745 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND... maintenance: Transmission lines. (a) Each transmission line valve that might be required during any...

  17. 49 CFR 192.179 - Transmission line valves.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Transmission line valves. 192.179 Section 192.179... BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Design of Pipeline Components § 192.179 Transmission line valves. (a) Each transmission line, other than offshore segments, must have sectionalizing...

  18. 49 CFR 192.719 - Transmission lines: Testing of repairs.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Transmission lines: Testing of repairs. 192.719 Section 192.719 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND... Transmission lines: Testing of repairs. (a) Testing of replacement pipe. If a segment of transmission line...

  19. 49 CFR 192.745 - Valve maintenance: Transmission lines.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Valve maintenance: Transmission lines. 192.745 Section 192.745 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND... maintenance: Transmission lines. (a) Each transmission line valve that might be required during any...

  20. 32 CFR 644.431 - Power transmission lines.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 32 National Defense 4 2013-07-01 2013-07-01 false Power transmission lines. 644.431 Section 644... Power transmission lines. (a) Authority. Pursuant to the provisions of section 13(d) of the Surplus... power transmission line and the right of way acquired for its construction is needed for or adaptable...

  1. 75 FR 25195 - Kake to Petersburg Transmission Line Intertie Project

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-07

    ... Forest Service Kake to Petersburg Transmission Line Intertie Project AGENCY: Forest Service, USDA. ACTION... operate a new electric transmission line intertie that would extend west across the Tongass National... transmission line that would transmit power at either 69 or 138 kilovolt (kV) and consist of single wood...

  2. 49 CFR 192.719 - Transmission lines: Testing of repairs.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Transmission lines: Testing of repairs. 192.719 Section 192.719 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND... Transmission lines: Testing of repairs. (a) Testing of replacement pipe. If a segment of transmission line...

  3. 49 CFR 192.485 - Remedial measures: Transmission lines.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Remedial measures: Transmission lines. 192.485... Control § 192.485 Remedial measures: Transmission lines. (a) General corrosion. Each segment of transmission line with general corrosion and with a remaining wall thickness less than that required for...

  4. 49 CFR 192.745 - Valve maintenance: Transmission lines.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Valve maintenance: Transmission lines. 192.745 Section 192.745 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND... maintenance: Transmission lines. (a) Each transmission line valve that might be required during any...

  5. 49 CFR 192.719 - Transmission lines: Testing of repairs.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Transmission lines: Testing of repairs. 192.719 Section 192.719 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND... Transmission lines: Testing of repairs. (a) Testing of replacement pipe. If a segment of transmission line...

  6. 49 CFR 192.485 - Remedial measures: Transmission lines.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Remedial measures: Transmission lines. 192.485... Control § 192.485 Remedial measures: Transmission lines. (a) General corrosion. Each segment of transmission line with general corrosion and with a remaining wall thickness less than that required for...

  7. 49 CFR 192.719 - Transmission lines: Testing of repairs.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Transmission lines: Testing of repairs. 192.719 Section 192.719 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND... Transmission lines: Testing of repairs. (a) Testing of replacement pipe. If a segment of transmission line...

  8. 49 CFR 192.485 - Remedial measures: Transmission lines.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Remedial measures: Transmission lines. 192.485... Control § 192.485 Remedial measures: Transmission lines. (a) General corrosion. Each segment of transmission line with general corrosion and with a remaining wall thickness less than that required for...

  9. 49 CFR 192.719 - Transmission lines: Testing of repairs.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Transmission lines: Testing of repairs. 192.719 Section 192.719 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND... Transmission lines: Testing of repairs. (a) Testing of replacement pipe. If a segment of transmission line...

  10. 49 CFR 192.485 - Remedial measures: Transmission lines.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Remedial measures: Transmission lines. 192.485... Control § 192.485 Remedial measures: Transmission lines. (a) General corrosion. Each segment of transmission line with general corrosion and with a remaining wall thickness less than that required for...

  11. 49 CFR 192.745 - Valve maintenance: Transmission lines.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Valve maintenance: Transmission lines. 192.745 Section 192.745 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND... maintenance: Transmission lines. (a) Each transmission line valve that might be required during any...

  12. 49 CFR 192.485 - Remedial measures: Transmission lines.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Remedial measures: Transmission lines. 192.485... Control § 192.485 Remedial measures: Transmission lines. (a) General corrosion. Each segment of transmission line with general corrosion and with a remaining wall thickness less than that required for...

  13. 49 CFR 192.179 - Transmission line valves.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Transmission line valves. 192.179 Section 192.179... BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Design of Pipeline Components § 192.179 Transmission line valves. (a) Each transmission line, other than offshore segments, must have sectionalizing...

  14. 32 CFR 644.431 - Power transmission lines.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 4 2010-07-01 2010-07-01 true Power transmission lines. 644.431 Section 644.431... transmission lines. (a) Authority. Pursuant to the provisions of section 13(d) of the Surplus Property Act of... transmission line and the right of way acquired for its construction is needed for or adaptable to...

  15. 32 CFR 644.431 - Power transmission lines.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 32 National Defense 4 2011-07-01 2011-07-01 false Power transmission lines. 644.431 Section 644... Power transmission lines. (a) Authority. Pursuant to the provisions of section 13(d) of the Surplus... power transmission line and the right of way acquired for its construction is needed for or adaptable...

  16. Modeling Transmission Line Networks Using Quantum Graphs

    NASA Astrophysics Data System (ADS)

    Koch, Trystan; Antonsen, Thomas

    Quantum graphs--one dimensional edges, connecting nodes, that support propagating Schrödinger wavefunctions--have been studied extensively as tractable models of wave chaotic behavior (Smilansky and Gnutzmann 2006, Berkolaiko and Kuchment 2013). Here we consider the electrical analog, in which the graph represents an electrical network where the edges are transmission lines (Hul et. al. 2004) and the nodes contain either discrete circuit elements or intricate circuit elements best represented by arbitrary scattering matrices. Including these extra degrees of freedom at the nodes leads to phenomena that do not arise in simpler graph models. We investigate the properties of eigenfrequencies and eigenfunctions on these graphs, and relate these to the statistical description of voltages on the transmission lines when driving the network externally. The study of electromagnetic compatibility, the effect of external radiation on complicated systems with numerous interconnected cables, motivates our research into this extension of the graph model. Work supported by the Office of Naval Research (N0014130474) and the Air Force Office of Scientific Research.

  17. A radial transmission line material measurement apparatus

    SciTech Connect

    Warne, L.K.; Moyer, R.D.; Koontz, T.E.; Morris, M.E.

    1993-05-01

    A radial transmission line material measurement sample apparatus (sample holder, offset short standards, measurement software, and instrumentation) is described which has been proposed, analyzed, designed, constructed, and tested. The purpose of the apparatus is to obtain accurate surface impedance measurements of lossy, possibly anisotropic, samples at low and intermediate frequencies (vhf and low uhf). The samples typically take the form of sections of the material coatings on conducting objects. Such measurements thus provide the key input data for predictive numerical scattering codes. Prediction of the sample surface impedance from the coaxial input impedance measurement is carried out by two techniques. The first is an analytical model for the coaxial-to-radial transmission line junction. The second is an empirical determination of the bilinear transformation model of the junction by the measurement of three full standards. The standards take the form of three offset shorts (and an additional lossy Salisbury load), which have also been constructed. The accuracy achievable with the device appears to be near one percent.

  18. Effects of 60 Hz electric fields on operant and social stress behavior of nonhuman primates. Quarterly technical progress report No. 20, September 28-December 20, 1985

    SciTech Connect

    Rogers, W.R.

    1986-01-03

    This research program will evaluate the aversive character of exposure to 60 Hz electric fields by determining the threshold intensity which produces avoidance or escape responses, will estimate the threshold intensity for detection of 60 Hz electric fields, will assess effects of chronic exposure to 60 Hz electric fields on the performance of two operant conditioning tasks, fixed ratio and differential reinforcement of low rate responding, will investigate, using the systematic quantitative observational sampling methods of primatology, the possible stress-inducing effects of chronic exposure to 60 Hz electric fields on the behavior of baboons living in small social groups. In all experiments, the electric fields will be described, characterized, and controlled to account for recognized artifacts associated with high intensity 60 Hz electric fields and the health of all subjects will be described using the methods of primate veterinary medicine.

  19. Effects of 60 Hz electric fields on operant and social stress behaviors of nonhuman primates. Project technical status report, November 23, 1985-January 17, 1986. [Papio cynocephalus

    SciTech Connect

    Not Available

    1986-01-24

    The objective was to investigate, using baboons (superspecies Papio cynocephalus) as surrogates, possible behavioral effects associated with exposure to high intensity 60 Hz electric fields. This program consists of four major projects. The first will evaluate the potential aversive character of exposure to 60 Hz electric fields by determining the threshold intensity which produces avoidance or escape responses. The second project will estimate the threshold intensity for detection of 60 Hz electric fields. The third will assess effects of chronic exposure to 60 Hz electric fields on the performance of two operant conditioning tasks, fixed ratio (FR) and differential reinforcement of low rate responding (DRL). The fourth will investigate the possible stress-inducing effects of chronic exposure to 60 Hz electric fields on the behavior of baboons living in small social groups.

  20. Coils performances of superconducting cables for 50/60 Hz applications

    SciTech Connect

    Lacaze, A.; Laumond, Y. ); Tavergnier, J.P.; Fevrier, A.; Verhaege, T. ); Dalle, B.; Ansart, A. )

    1991-03-01

    Multifilamentary superconducting wires with a greatly reduced level of losses have been produced with unit lengths of several tens of kilometers by AISA (GEC ALSTHOM - IGC). With the reduction of the filament diameter, proximity effects are avoided and the authors take a maximum advantage of the reversible motion of flux lines, so that the hysteretic and matrix losses are lower. In this paper the authors report on 50 Hz and DC quench currents, 50 Hz AC losses, 50 Hz electromagnetic stability results.

  1. 49 CFR 192.707 - Line markers for mains and transmission lines.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Line markers for mains and transmission lines. 192... § 192.707 Line markers for mains and transmission lines. (a) Buried pipelines. Except as provided in... buried main and transmission line: (1) At each crossing of a public road and railroad; and (2)...

  2. 49 CFR 192.707 - Line markers for mains and transmission lines.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Line markers for mains and transmission lines. 192... § 192.707 Line markers for mains and transmission lines. (a) Buried pipelines. Except as provided in... buried main and transmission line: (1) At each crossing of a public road and railroad; and (2)...

  3. Clinical progression of transplanted large granular lymphocytic leukemia in Fischer 334 rats exposed to 60 Hz magnetic fields

    SciTech Connect

    Morris, James E. ); Sasser, Lyle B. ); Miller, Douglas L. ); Dagle, Gerald E.; Rafferty, C N.; Ebi, K L.; Anderson, Larry E. )

    1999-01-19

    The purpose of this study was to determine if 60 Hz magnetic fields could alter the clinical progression of leukemia in an animal model. Large granular lymphocytic (LGL) leukemia cells from spleens of leukemic rats were transplanted into young male Fischer rats, producing signs of leukemia in about 2-3 months. The animals were injected with 2.2 x 107 LGL leukemia cells at the initiation of the study and assigned to 4 treatment groups 108/group) as follows: (1) 10 G linearly polarized 60 Hz magnetic fields, (2) sham exposed null energized unit with residual 20 mG fields, (3) ambient controls < 1 mG, and (4) positive controls (a single 5 Gy whole body exposure to 60Co 4 days prior to initiation of exposure). The magnetic fields were activated 20h/day, 7 days/week. Eighteen Rats (18 from each treatment group) were bled, killed, and evaluated at a5, 6, 7, 8, 9, and 11 weeks of exposure. Hematological endpoints, changes in spleen growth, and LGL cell infiltration into the spleen and liver were measured to evaluate the leukemia progression. Significant differences were not detected between the magnetic field exposed groups and the ambient control group, although the clinical progress of leukemia was enhanced in the positive control animals. These data indicate that exposure to sinusoidal, linearly polarized 60 Hz, 10 G magnetic fields did not significantly alter the clinical progression of LGL leukemia. Furthermore, the data are in general agreement with previous results of a companion repeated-bleeding study.

  4. Are the stray 60-Hz electromagnetic fields associated with the distribution and use of electric power a significant cause of cancer?

    PubMed

    Jackson, J D

    1992-04-15

    The putative causal relation between ambient low-frequency (50 or 60 Hz) electromagnetic fields (necessarily present in living and working environments because of our ever increasing use of electrical devices) and cancer, especially leukemia, can be tested on the large scale by examining historical data on the growth of the generation and consumption of electric power since 1900 and corresponding data on cancer death and incidence rates. The United States per capita generation and residential consumption of electric power have grown roughly exponentially since 1900; total per capita generation has increased by a factor of 10 since 1940, and per capita residential consumption has increased by a factor of 20 in the same period. The ubiquitous stray fields from power distribution lines and internal and external wiring in buildings have grown in the same proportions. In contrast to the explosive increase in the generation and use of electricity, the age-adjusted cancer death rate for the population as a whole shows only a slight rise since 1900. When respiratory cancers (largely caused by tobacco use) are subtracted, the remaining death rate has actually fallen since 1940. That the death rate may have fallen because of better diagnosis and treatment, despite a rising incidence rate, is not substantiated, especially for leukemia, including childhood leukemia, where the incidence rate has been constant or declining slightly for the past 25 yr. The absence of any appreciable change in the national cancer incidence rates during a period in which residential use of electric power has increased dramatically shows that the associated stray 50- or 60-Hz electromagnetic fields pose no significant hazard to the average individual. PMID:1565645

  5. Constraints of thermal noise on the effects of weak 60-Hz magnetic fields acting on biological magnetite.

    PubMed Central

    Adair, R K

    1994-01-01

    Previous calculations of limits imposed by thermal noise on the effects of weak 60-Hz magnetic fields on biological magnetite are generalized and extended to consider multiple signals, the possibility of anomalously large magnetosome structures, and the possibility of anomalously small cytoplasm viscosities. The results indicate that the energies transmitted to the magnetite elements by fields less than 5 microT, characteristic of the electric power distribution system, will be much less than thermal noise energies. Hence, the effects of such weak fields will be masked by that noise and cannot be expected to affect biology or, therefore, the health of populations. PMID:8159681

  6. Analysis of the 60-Hz power system at KSC: The Orsino substation

    NASA Technical Reports Server (NTRS)

    Kalu, Alex O.

    1989-01-01

    An analysis of the Orsino Substation, a component (50 percent) of the 60-Hertz electric power system at the Kennedy Space Center, is presented. Presented here are separate single-line diagrams of the sixteen feeder circuits to permit easy access to information on the individual feeders for future planning. The load condition of each feeder and load break switch are presented and a heuristic reliability analysis of the system is performed. Information is given about the system fashion useful for decision making purposes. The beauty of it is in the simplified manner by which information about the system can be obtained.

  7. From sunlight in space to 60 Hz on earth - The losses along the way. [satellite solar power transmission efficiency

    NASA Technical Reports Server (NTRS)

    Denman, O. S.

    1978-01-01

    The space-to-ground links for the Solar Power Satellite System are discussed in terms of worst, best, and nominal efficiency used in the development of the preliminary design. An uncertainty analysis of this design illustrates the effect of link efficiency on SPS size and mass. It is shown that a solar power satellite can deliver power to a ground-based utility for 4 to 5 cents per kWh, depending on the efficiency of the solar cells available in 1987. The overall efficiency of converting sunlight in space to electric power delivered to utilities ranged from 3.83% for the worst combination of efficiencies to 9.5% for the best, with a nominal efficiency of 7.12%.

  8. Method for bonding a transmission line to a downhole tool

    DOEpatents

    Hall, David R.; Fox, Joe

    2007-11-06

    An apparatus for bonding a transmission line to the central bore of a downhole tool includes a pre-formed interface for bonding a transmission line to the inside diameter of a downhole tool. The pre-formed interface includes a first surface that substantially conforms to the outside contour of a transmission line and a second surface that substantially conforms to the inside diameter of a downhole tool. In another aspect of the invention, a method for bonding a transmission line to the inside diameter of a downhole tool includes positioning a transmission line near the inside wall of a downhole tool and placing a mold near the transmission line and the inside wall. The method further includes injecting a bonding material into the mold and curing the bonding material such that the bonding material bonds the transmission line to the inside wall.

  9. Nonlinear transmission line based electron beam driver

    NASA Astrophysics Data System (ADS)

    French, David M.; Hoff, Brad W.; Tang, Wilkin; Heidger, Susan; Allen-Flowers, Jordan; Shiffler, Don

    2012-12-01

    Gated field emission cathodes can provide short electron pulses without the requirement of laser systems or cathode heating required by photoemission or thermionic cathodes. The large electric field requirement for field emission to take place can be achieved by using a high aspect ratio cathode with a large field enhancement factor which reduces the voltage requirement for emission. In this paper, a cathode gate driver based on the output pulse train from a nonlinear transmission line is experimentally demonstrated. The application of the pulse train to a tufted carbon fiber field emission cathode generates short electron pulses. The pulses are approximately 2 ns in duration with emission currents of several mA, and the train contains up to 6 pulses at a frequency of 100 MHz. Particle-in-cell simulation is used to predict the characteristic of the current pulse train generated from a single carbon fiber field emission cathode using the same technique.

  10. Complex magnetically insulated transmission line oscillator

    NASA Astrophysics Data System (ADS)

    Fan, Yu-Wei; Zhong, Hui-Huang; Shu, Ting; Li, Zhi-Qiang

    2008-08-01

    A magnetically insulated transmission line oscillator (MILO) is a crossed-field device designed specifically to generate microwave power at the gigawatt level, which is a major hotspot in the field of high-power microwaves (HPM) research at present. It is one of the major thrust for MILO development to improve the power conversion efficiency. In order to improve the power conversion efficiency of MILO, a complex MILO is presented and investigated theoretically and numerically, which comprises the MILO-1 and MILO-2. The MILO-2 is used as the load of the MILO-1. The theoretical analyses show that the maximum power conversion efficiency of the complex MILO has an increase of about 50% over the conventional load-limited MILO. The complex MILO is optimized with KARAT code (V. P. Tarakanov, Berkeley Research Associates, Inc., 1992), and the simulation results agree with the theoretical results.

  11. Networks of nonlinear superconducting transmission line resonators

    NASA Astrophysics Data System (ADS)

    Leib, M.; Deppe, F.; Marx, A.; Gross, R.; Hartmann, M. J.

    2012-07-01

    We investigate a network of coupled superconducting transmission line resonators, each of them made nonlinear with a capacitively shunted Josephson junction coupling to the odd flux modes of the resonator. The resulting eigenmode spectrum shows anticrossings between the plasma mode of the shunted junction and the odd resonator modes. Notably, we find that the combined device can inherit the complete nonlinearity of the junction, allowing for a description as a harmonic oscillator with a Kerr nonlinearity. Using a dc SQUID instead of a single junction, the nonlinearity can be tuned between 10 kHz and 4 MHz while maintaining resonance frequencies of a few gigahertz for realistic device parameters. An array of such nonlinear resonators can be considered a scalable superconducting quantum simulator for a Bose-Hubbard Hamiltonian. The device would be capable of accessing the strongly correlated regime and be particularly well suited for investigating quantum many-body dynamics of interacting particles under the influence of drive and dissipation.

  12. Nonlinear transmission line based electron beam driver.

    PubMed

    French, David M; Hoff, Brad W; Tang, Wilkin; Heidger, Susan; Allen-Flowers, Jordan; Shiffler, Don

    2012-12-01

    Gated field emission cathodes can provide short electron pulses without the requirement of laser systems or cathode heating required by photoemission or thermionic cathodes. The large electric field requirement for field emission to take place can be achieved by using a high aspect ratio cathode with a large field enhancement factor which reduces the voltage requirement for emission. In this paper, a cathode gate driver based on the output pulse train from a nonlinear transmission line is experimentally demonstrated. The application of the pulse train to a tufted carbon fiber field emission cathode generates short electron pulses. The pulses are approximately 2 ns in duration with emission currents of several mA, and the train contains up to 6 pulses at a frequency of 100 MHz. Particle-in-cell simulation is used to predict the characteristic of the current pulse train generated from a single carbon fiber field emission cathode using the same technique. PMID:23277977

  13. Nonlinear transmission line based electron beam driver

    SciTech Connect

    French, David M.; Hoff, Brad W.; Tang Wilkin; Heidger, Susan; Shiffler, Don; Allen-Flowers, Jordan

    2012-12-15

    Gated field emission cathodes can provide short electron pulses without the requirement of laser systems or cathode heating required by photoemission or thermionic cathodes. The large electric field requirement for field emission to take place can be achieved by using a high aspect ratio cathode with a large field enhancement factor which reduces the voltage requirement for emission. In this paper, a cathode gate driver based on the output pulse train from a nonlinear transmission line is experimentally demonstrated. The application of the pulse train to a tufted carbon fiber field emission cathode generates short electron pulses. The pulses are approximately 2 ns in duration with emission currents of several mA, and the train contains up to 6 pulses at a frequency of 100 MHz. Particle-in-cell simulation is used to predict the characteristic of the current pulse train generated from a single carbon fiber field emission cathode using the same technique.

  14. Case-control study of childhood cancer and exposure to 60-Hz magnetic fields

    SciTech Connect

    Savitz, D.A.; Wachtel, H.; Barnes, F.A.; John, E.M.; Tvrdik, J.G.

    1988-07-01

    Concern with health effects of extremely low frequency magnetic fields has been raised by epidemiologic studies of childhood cancer in relation to proximity to electric power distribution lines. This case-control study was designed to assess the relation between residential exposure to magnetic fields and the development of childhood cancer. Eligible cases consisted of all 356 residents of the five-county 1970 Denver, Colorado Standard Metropolitan Statistical Area aged 0-14 years who were diagnosed with any form of cancer between 1976 and 1983. Controls were selected by random digit dialing to approximate the case distribution by age, sex, and telephone exchange area. Exposure was characterized through in-home electric and magnetic field measurements under low and high power use conditions and wire configuration codes, a surrogate measure of long-term magnetic field levels. Measured magnetic fields under low power use conditions had a modest association with cancer incidence; a cutoff score of 2.0 milligauss resulted in an odds ratio of 1.4 (95% confidence interval (CI) = 0.6-2.9) for total cancers and somewhat larger odds ratios (ORs) for leukemias (OR = 1.9), lymphomas (OR = 2.2), and soft tissue sarcomas (OR = 3.3). Neither magnetic fields (OR = 1.0) nor electric fields (OR = 0.9) under high power use conditions were related to total cancers. Wire codes associated with higher magnetic fields were more common among case than control homes. The odds ratio to contrast very high and high to very low, low, and buried wire codes was 1.5 (95% CI = 1.0-2.3) for total cases, with consistency across cancer subgroups except for brain cancer (OR = 2.0) and lymphomas (OR = 0.8). Contrasts of very high to buried wire code homes produced larger, less precise odds ratios of 2.3 for total cases, 2.9 for leukemias, and 3.3 for lymphomas.

  15. 49 CFR 192.705 - Transmission lines: Patrolling.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Transmission lines: Patrolling. 192.705 Section... NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Maintenance § 192.705 Transmission... adjacent to the transmission line right-of-way for indications of leaks, construction activity, and...

  16. 49 CFR 192.709 - Transmission lines: Record keeping.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Transmission lines: Record keeping. 192.709 Section 192.709 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND... Transmission lines: Record keeping. Each operator shall maintain the following records for transmission...

  17. 49 CFR 192.705 - Transmission lines: Patrolling.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Transmission lines: Patrolling. 192.705 Section... NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Maintenance § 192.705 Transmission... adjacent to the transmission line right-of-way for indications of leaks, construction activity, and...

  18. 49 CFR 192.705 - Transmission lines: Patrolling.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Transmission lines: Patrolling. 192.705 Section... NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Maintenance § 192.705 Transmission... adjacent to the transmission line right-of-way for indications of leaks, construction activity, and...

  19. 49 CFR 192.709 - Transmission lines: Record keeping.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Transmission lines: Record keeping. 192.709 Section 192.709 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND... Transmission lines: Record keeping. Each operator shall maintain the following records for transmission...

  20. 49 CFR 192.709 - Transmission lines: Record keeping.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Transmission lines: Record keeping. 192.709 Section 192.709 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND... Transmission lines: Record keeping. Each operator shall maintain the following records for transmission...

  1. 49 CFR 192.709 - Transmission lines: Record keeping.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Transmission lines: Record keeping. 192.709 Section 192.709 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND... Transmission lines: Record keeping. Each operator shall maintain the following records for transmission...

  2. 49 CFR 192.705 - Transmission lines: Patrolling.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Transmission lines: Patrolling. 192.705 Section... NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Maintenance § 192.705 Transmission... adjacent to the transmission line right-of-way for indications of leaks, construction activity, and...

  3. 49 CFR 192.705 - Transmission lines: Patrolling.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Transmission lines: Patrolling. 192.705 Section... NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Maintenance § 192.705 Transmission... adjacent to the transmission line right-of-way for indications of leaks, construction activity, and...

  4. 49 CFR 192.709 - Transmission lines: Record keeping.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Transmission lines: Record keeping. 192.709 Section 192.709 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND... Transmission lines: Record keeping. Each operator shall maintain the following records for transmission...

  5. Big Creek Hydroelectric System, East & West Transmission Line, 241mile ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Big Creek Hydroelectric System, East & West Transmission Line, 241-mile transmission corridor extending between the Big Creek Hydroelectric System in the Sierra National Forest in Fresno County and the Eagle Rock Substation in Los Angeles, California, Visalia, Tulare County, CA

  6. Radio frequency communication system utilizing radiating transmission lines

    DOEpatents

    Struven, Warren C.

    1984-01-01

    A radio communication system for use in tunnels, mines, buildings or other shielded locations in which a pair of radiating transmission lines (30), (31) extend through such location in spaced coextensive relation to each other. Each transmission line (30), (31) has at least one unidirectional amplifier (32), (33) interposed therein with the sense of the unidirectional amplifier (32) of one transmission line (30) being opposite to the sense of the unidirectional amplifier (33) of the other transmission line (31). Each of the amplifiers (32), (33) has a gain which is less than the coupling loss between the transmission lines (30), (31). Two or more mobile transceivers (35) in the location served by the system are coupled to the transmission lines (30), (31) by electromagnetic wave propagation in space in order to communicate directly with each other at a given radio frequency within the frequency range of the system.

  7. Investigation of a stripline transmission line structure for gyromagnetic nonlinear transmission line high power microwave sources

    NASA Astrophysics Data System (ADS)

    Reale, D. V.; Parson, J. M.; Neuber, A. A.; Dickens, J. C.; Mankowski, J. J.

    2016-03-01

    A stripline gyromagnetic nonlinear transmission line (NLTL) was constructed out of yttrium iron garnet ferrite and tested at charge voltages of 35 kV-55 kV with bias fields ranging from 10 kA/m to 20 kA/m. Typically, high power gyromagnetic NLTLs are constructed in a coaxial geometry. While this approach has many advantages, including a uniform transverse electromagnetic (TEM) mode, simple interconnection between components, and the ability to use oil or pressurized gas as an insulator, the coaxial implementation suffers from complexity of construction, especially when using a solid insulator. By moving to a simpler transmission line geometry, NLTLs can be constructed more easily and arrayed on a single substrate. This work represents a first step in exploring the suitability of various transmission line structures, such as microstrips and coplanar waveguides. The resulting high power microwave (HPM) source operates in ultra high frequency (UHF) band with an average bandwidth of 40.1% and peak rf power from 2 MW to 12.7 MW.

  8. Investigation of a stripline transmission line structure for gyromagnetic nonlinear transmission line high power microwave sources.

    PubMed

    Reale, D V; Parson, J M; Neuber, A A; Dickens, J C; Mankowski, J J

    2016-03-01

    A stripline gyromagnetic nonlinear transmission line (NLTL) was constructed out of yttrium iron garnet ferrite and tested at charge voltages of 35 kV-55 kV with bias fields ranging from 10 kA/m to 20 kA/m. Typically, high power gyromagnetic NLTLs are constructed in a coaxial geometry. While this approach has many advantages, including a uniform transverse electromagnetic (TEM) mode, simple interconnection between components, and the ability to use oil or pressurized gas as an insulator, the coaxial implementation suffers from complexity of construction, especially when using a solid insulator. By moving to a simpler transmission line geometry, NLTLs can be constructed more easily and arrayed on a single substrate. This work represents a first step in exploring the suitability of various transmission line structures, such as microstrips and coplanar waveguides. The resulting high power microwave (HPM) source operates in ultra high frequency (UHF) band with an average bandwidth of 40.1% and peak rf power from 2 MW to 12.7 MW. PMID:27036802

  9. Effects of 60-Hz electric and magnetic fields on operant and social behavior and on neuroendocrine system of nonhuman primates

    SciTech Connect

    Rogers, W.R.; Coelho, A.M.; Easley, S.P.; Orr, J.L.; Reiter, R.J.; Rhodes, J.W.

    1992-09-24

    A series of pioneering electric and magnetic field experiments were completed using nonhuman primates and a unique, well-engineered, and reliable exposure facility. Effects of operant behavior, social behavior, and serum melatonin concentration were examined using 60 Hz field combinations of other 6 W/m and 0.6 G or 30 W/m and 1.0 G. Observations noted in the course of this study include: Combines electric and magnetic field exposure does not have any important effect on short-term memory; the transitory increases in social behavior observed in previous electric fields did not occur; combined electric and magnetic field exposure might lead to reduced behavioral frequency in baboon social groups; three experiments clearly establish that one set of exposure conditions does not produce molatonin suppression in nonhuman primates; and a small pilot experiment suggests that a different exposure protocol might result in melatonin suppression.

  10. Effect of 60 Hz electromagnetic fields on the activity of hsp70 promoter: an in vivo study

    PubMed Central

    Rodríguez-De la Fuente, Abraham O.; Alcocer-González, Juan M.; Heredia-Rojas, J. Antonio; Rodríguez-Padilla, Cristina; Rodríguez-Flores, Laura E.; Santoyo-Stephano, Martha A.; Castañeda-Garza, Esperanza; Taméz-Guerra, Reyes S.

    2012-01-01

    Exposure to EMFs (electromagnetic fields) results in a number of important biological changes, including modification of genetic expression. We have investigated the effect of 60 Hz sinusoidal EMFs at a magnetic flux density of 80 μT on the expression of the luciferase gene contained in a plasmid labelled as pEMF (EMF plasmid). This gene construct contains the specific sequences for the induction of hsp70 (heat-shock protein 70) expression by EMFs, as well as the reporter for the luciferase gene. The pEMF vector was electrotransferred into quadriceps muscles of BALB/c mice that were later exposed to EMFs. Increased luciferase expression was observed in mice exposed to EMFs 2 h daily for 7 days compared with controls (P<0.05). These data along with other reports in the literature suggest that EMFs can have far-reaching effects on the genome. PMID:23124775

  11. Study of the behavioral and biological effects of high strength 60 HZ electric fields. Quarterly technical progress report No. 15, 12 May 1984-3 August 1984

    SciTech Connect

    Not Available

    1984-08-15

    Progress is reported in the construction of a test facility for studying the effects of high intensity, 60 Hz electric fields on baboons. Effects to be studied include operant out social behaviors. (ACR)

  12. Effects of exposure to a 60-kV/m, 60-Hz electric field on the social behavior of baboons

    SciTech Connect

    Easley, S.P.; Coelho, A.M. Jr.; Rogers, W.R. )

    1991-01-01

    The authors found in a previously reported study that exposure to a 30-kV/m, 60-Hz electric field had significant effects on the social behavior of baboons. However, it was not established whether or not the effects were related specifically to the 30-kV/m intensity of the field. A new experiment was conducted to determine whether or not exposure to a 60-Hz electric field at 60 kV/m would produce like changes in the baboons' social behavior. They exposed one group of eight male baboons to an electric field 12 hours a day, 7 days a week, for 6 weeks. A second group of eight animals was maintained under sham-exposure (control) conditions. Rates of performing on each of six categories of social behavior and on four categories of nonsocial behavior were used as criteria for comparing exposed with unexposed subjects and for within-group comparisons during three six-week experimental periods: Pre-Exposure, Exposure, and Post-Exposure. The results indicate that (1) during the exposure period, exposed animals exhibited statistically significant differences from controls in means of performance rates based on several behavioral categories; (2) across all three periods, within-group comparisons revealed that behaviors of exposed baboons were significantly affected by exposure to the electric field; (3) changes in performance levels probably reflect a stress response to the electric field; and (4) the means of response rates of animals exposed at 60 kV/m were higher, but not double, those of animals exposed at 30 kV/m. As in the 30-kV/m experiment, animals exposed at 60 kV/m exhibited significant differences in performances of Passive Affinity, Tension, and Stereotypy. Mean rates of performing these categories were 122% (Passive Affinity), 48% (Tension), and 40% (Stereotypy) higher in the exposed group than in the control group during exposure to the 60-kV/m field.

  13. Reproduction, growth, and development of rats during chronic exposure to multiple field strengths of 60-Hz electric fields

    SciTech Connect

    Rommereim, D.N.; Rommereim, R.L.; Sikov, M.R.; Buschbom, R.L.; Anderson, L.E. )

    1990-04-01

    A study with multiple exposure groups and large group sizes was performed to establish whether exposure to 60-Hz electric fields would result in reproductive and developmental toxicity. A response model was developed from previous results and tested in groups of rats exposed to electric fields at various field strengths. Female rats were mated, and sperm-positive animals randomly distributed among four groups: sham-exposed or exposed to 10, 65, or 130 kV/m, 60-Hz vertical electric fields. Animals were exposed for 19 hr/day throughout the experiment. During gestation, exposure to the higher field strengths resulted in slightly depressed weight gains of dams. Offspring were born in the field and remained with their dams through the suckling period. Numbers of pups per litter and pup mortality did not differ among the exposure groups. Dams exposed at 65 kV/m lost slightly more weight through the lactation period than the control group. Male pups exposed to higher field strengths gained slightly less weight from 4 to 21 days of age than did sham-exposed animals. At weaning, two F1 females per litter (randomly selected) continued on the same exposure regimen were mated at 11 weeks of age to unexposed males, and euthanized at 20 days of gestation. Uterine contents were evaluated, and all live fetuses were weighed and examined for external, visceral, and skeletal malformations. Fertility and gestational weight gain of F1 females were not affected by exposure, nor was prenatal viability or fetal body weight. No significant increase in the incidence of litters with malformations was observed. Although no developmental toxicity was detected, exposures produced physical changes in the dams, evidenced as a rust-colored deposit on the muzzle and ears (chromodacryorrhea) that increased in incidence and severity at 65 and 130 kV/m.

  14. Effects of a 60 Hz magnetic field on photosynthetic CO2 uptake and early growth of radish seedlings.

    PubMed

    Yano, Akira; Ohashi, Yoshiaki; Hirasaki, Tomoyuki; Fujiwara, Kazuhiro

    2004-12-01

    Photosynthetic CO2 uptake rate and early growth parameters of radish Raphanus sativus L. seedlings exposed to an extremely low frequency magnetic field (ELF MF) were investigated. Radish seedlings were exposed to a 60 Hz, 50 microT(rms) (root mean square) sinusoidal magnetic field (MF) and a parallel 48 microT static MF for 6 or 15 d immediately after germination. Control seedlings were exposed to the ambient MF but not the ELF MF. The CO2 uptake rate of ELF MF exposed seedlings on day 5 and later was lower than that of the control seedlings. The dry weight and the cotyledon area of ELF MF exposed seedlings on day 6 and the fresh weight, the dry weight and the leaf area of ELF MF exposed seedlings on day 15 were significantly lower than those of the control seedlings, respectively. In another experiment, radish seedlings were grown without ELF MF exposure for 14 d immediately after germination, and then exposed to the ELF MF for about 2 h, and the photosynthetic CO2 uptake rate was measured during the short-term ELF MF exposure. The CO2 uptake rate of the same seedlings was subsequently measured in the ambient MF (control) without the ELF MF. There was no difference in the CO2 uptake rate of seedlings exposed to the ELF MF or the ambient MF. These results indicate that continuous exposure to 60 Hz, 50 microT(rms) sinusoidal MF with a parallel 48 microT static MF affects the early growth of radish seedlings, but the effect is not so severe that modification of photosynthetic CO2 uptake can observed during short-term MF exposure. PMID:15515039

  15. BIGEL analysis of gene expression in HL60 cells exposed to X rays or 60 Hz magnetic fields

    NASA Technical Reports Server (NTRS)

    Balcer-Kubiczek, E. K.; Zhang, X. F.; Han, L. H.; Harrison, G. H.; Davis, C. C.; Zhou, X. J.; Ioffe, V.; McCready, W. A.; Abraham, J. M.; Meltzer, S. J.

    1998-01-01

    We screened a panel of 1,920 randomly selected cDNAs to discover genes that are differentially expressed in HL60 cells exposed to 60 Hz magnetic fields (2 mT) or X rays (5 Gy) compared to unexposed cells. Identification of these clones was accomplished using our two-gel cDNA library screening method (BIGEL). Eighteen cDNAs differentially expressed in X-irradiated compared to control HL60 cells were recovered from a panel of 1,920 clones. Differential expression in experimental compared to control cells was confirmed independently by Northern blotting of paired total RNA samples hybridized to each of the 18 clone-specific cDNA probes. DNA sequencing revealed that 15 of the 18 cDNA clones produced matches with the database for genes related to cell growth, protein synthesis, energy metabolism, oxidative stress or apoptosis (including MYC, neuroleukin, copper zinc-dependent superoxide dismutase, TC4 RAS-like protein, peptide elongation factor 1alpha, BNIP3, GATA3, NF45, cytochrome c oxidase II and triosephosphate isomerase mRNAs). In contrast, BIGEL analysis of the same 1,920 cDNAs revealed no differences greater than 1.5-fold in expression levels in magnetic-field compared to sham-exposed cells. Magnetic-field-exposed and control samples were analyzed further for the presence of mRNA encoding X-ray-responsive genes by hybridization of the 18 specific cDNA probes to RNA from exposed and control HL60 cells. Our results suggest that differential gene expression is induced in approximately 1% of a random pool of cDNAs by ionizing radiation but not by 60 Hz magnetic fields under the present experimental conditions.

  16. Investigation of effects of 60-Hz electric and magnetic fields on operant and social behavior and on the neuroendocrine system of nonhuman primates

    SciTech Connect

    Rhodes, J.W.

    1992-07-14

    The objective of this program is to investigate behavioral and neuroendocrine effects associated with exposure to 60-Hz electric and magnetic fields, using the baboon (Papio cynocephalus). Results from this program are used to estimate consequences of human exposure to the electric and magnetic fields associated with electric power transmission. Electric and magnetic field measurements for Experiment IIIA (Confirmatory), Experiment IV and Social Behavior portion of Experiment III are presented. The systems for the production and monitoring of the fields performed satisfactorily during Experiment IIIA and during all but the last part of Experiment IV. In Experiment III, two-way repeated analyses of variance revealed statistically significant Group (Exposed and Sham Exposed) and Period (Baseline. Exposure, and Post-Exposure) main effects. Two significant Period by Group interactions were also found. Seven of the ten behavioral categories showed a main effect of Period. Two-sample t-test comparisons of the two groups for each period indicated that performance rates in two behavioral categories (Stereotypy and Posture) were significantly lower in the Exposure Group. In general, the Exposed subjects exhibited a trend of progressively lower performance rates across the three periods. Specific accomplishments reported in this document were: measurement of electric and magnetic fields for Experiments IIIA and IV, completed analysis of the Social Behavioral data from Experiment III, and a detailed discussion of statistical methods employed on the Social Behavioral portion of Experiment III, and hematology data were collected and recorded for Operant and Social Behavioral subjects for Experiment IV.

  17. 49 CFR 192.707 - Line markers for mains and transmission lines.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Line markers for mains and transmission lines. 192... SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Maintenance § 192.707 Line markers for mains and transmission lines. (a) Buried pipelines. Except as provided...

  18. 49 CFR 192.707 - Line markers for mains and transmission lines.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Line markers for mains and transmission lines. 192... SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Maintenance § 192.707 Line markers for mains and transmission lines. (a) Buried pipelines. Except as provided...

  19. 49 CFR 192.707 - Line markers for mains and transmission lines.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Line markers for mains and transmission lines. 192... SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Maintenance § 192.707 Line markers for mains and transmission lines. (a) Buried pipelines. Except as provided...

  20. 75 FR 66750 - Albany-Eugene Transmission Line Rebuild Project

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-29

    ... Bonneville Power Administration Albany-Eugene Transmission Line Rebuild Project AGENCY: Bonneville Power... Transmission Line Rebuild Project EIS and requesting comments about the potential environmental impacts it should consider as it prepares the EIS for the proposed project. DATES: Written comments are due to...

  1. A 60 Hz electric and magnetic field exposure facility for nonhuman primates: Design and operational data during experiments

    SciTech Connect

    Rogers, W.R.; Lucas, J.H.; Cory, W.E.; Orr, J.L.; Smith, H.D.

    1995-12-31

    A unique exposure facility was designed and constructed to generate large-scale vertical electric fields (EF) of up to 65 kV/m and horizontal magnetic fields (MF) of up to 100 {micro}T (1G), so that the behavioral and neuroendocrine effects of 60 Hz EF or combined electric and magnetic field (E/MF) exposure could be examined using nonhuman primates as subjects. Facility design and operational problems and their solutions are presented, and representative operational data from four sets of experiments are provided. A specially designed, optically isolated, 4 cm spherical-dipole EF probe and a commercially available MF probe were used to map the EF and MF within the fiberglass animal cages. In addition, amplifiers, signal conditioners, and A/D converters provided EF, MF, and transformer signals to a microcomputer at 15 min intervals. The apparatus produced homogeneous, stable E/MF at the desired intensities, and the fiberglass cages did not produce appreciable distortion or attenuation. Levels of recognized EF artifacts such as corona and ozone were negligible. The facility worked as intended, providing a well-characterized and artifact-controlled environment for experiments with baboons (Papio cynocephalus).

  2. Effects of exposure to 30 kV/m, 60-Hz electric fields on the social behavior of baboons

    SciTech Connect

    Coelho, A.M. Jr.; Easley, S.P.; Rogers, W.R. )

    1991-01-01

    The authors tested the hypothesis that exposure to a 30-kV/m, 60-Hz electric field produces significant change (stress) in the social behavior of adult male baboons (Papio cynocephalus anubis). One group of eight baboons was exposed to an electric field (12 hours per day, 7 days per week for 6 weeks) while a second group of eight baboons was maintained in a sham-exposure (control) condition. Exposed subjects and control subjects were compared over three, six-week experimental periods (pre-exposure, exposure, and post-exposure). Performance rates of six categories of social behaviors (passive affinity, active affinity, approach, tension, threat, and attack) and four categories of nonsocial behaviors (forage, manipulate, posture, and stereotypy) were used to compare the two groups. The results of our study indicate that (1) there were no significant differences between the two groups during the pre-exposure or post-exposure periods; (2) during the exposure period, experimental and control groups exhibited statistically significant differences in the mean performance rates of three behavior categories; (3) within-group comparisons across periods indicate that the experimentally exposed group exhibited statistically significant changes in passive affinity, tension, and stereotypy; and (4) changes in behavior performance among the exposed subjects reflect a stress response to the electric field.

  3. Electric fields induced in chicken eggs by 60-Hz magnetic fields and the dosimetric importance of biological membranes

    SciTech Connect

    Miller, D.L. )

    1991-01-01

    Chicken eggs are convenient models for observing the effects of inhomogeneities and variations, such as those found in biological membranes and in cellular conductivities, on the distribution of internal electric fields as induced by exposure to magnetic fields. The vitelline membrane separates the yolk, which has a conductivity of 0.26 S/m, from the white, which has a conductivity of 0.85 S/m. A miniaturized probe with 2.4-mm resolution was used to measure induced fields in eggs placed in a uniform, 1-mT magnetic field at 60 Hz. The E fields induced in eggs with homogenized contents agreed with expectations based on simple theory. Results were similar to intact eggs unless the probe moved the yolk off-center, which greatly perturbed the induced fields. A more reproducible arrangement, which consisted of saline-agar filled dishes with a hole cut for test samples, was developed to enhance definition of electrical parameters. With this test system, the vitelline membrane was found to be responsible for most of the perturbation of the induced field, because it electrically isolates the yolk from the surrounding white. From a theoretical viewpoint, this dosimetry for the macroscopic egg yolk is analogous to the interaction of fields with microscopic cells. These findings may have important implications for research on biological effects of ELF electromagnetic fields, especially for studies of avian embryonic development.

  4. Lack of effect of a 60 Hz magnetic field on biomarkers of tumor promotion in the skin of SENCAR mice

    SciTech Connect

    Digiovanni, John; Johnston, D A.; Rupp, Tim; Sasser, Lyle B. ); Anderson, Larry E. ); Morris, James E. ); Miller, Douglas L. ); Kavet, R; Walborg, Earl R.

    1999-04-20

    It has been proposed that extremely low frequency (ELF) magnetic fields may enhance tumorigenesis through a co-promotional mechanism. This hypothesis has been further tested using the two-stage model of mouse skin carcinogenesis, i.e. 12-O-tetradecanoylphorbol-13-acetate (TPA)-induced promotion of skin carcinogenesis in mice initiated by a single subcarcinogenic dose of 7,12-dimethylbenz(a)anthracene. Experimentation utilized three different doses of TPA within its dose-response range (0.85, 1.70 or 3.40 nmol) and examined the following early biomarkers of tumor promotion after 1, 2 and 5 weeks of promotion: increases in epidermal thickness and the labeling index of epidermal cells, induction of epidermal ornithine decarboxylase activity and down regulation of epidermal protein kinase C activity. Mice exposed to a 60 Hz magnetic field having a flux density of 2 mT for 6 hr per day for 5 days per week were compared to mice exposed to an ambient magnetic field. Within the sensitivity limits of the biomarker methodology and the exposure parameters employed, no consistent, statistically significant effects, indicative of co-promotion by the magnetic field, were demonstrated.

  5. Survey of Magnetic Fields Near BPA 230-kV and 500-kV Transmission Lines.

    SciTech Connect

    Perrin, Nancy; Aggarwal, Rajinder Pal; Bracken, T. Daniel

    1991-05-20

    The purpose of this study was to characterize typical levels and variability of 60Hz magnetic fields at the centerline and edge of right-of-way of Bonneville Power Administration (BPA) 230-kV and 500-kV transmission lines. This was accomplished by taking magnetic field measurements at over 800 spans in Oregon and Washington. The spans were sampled using a stratified random sampling procedure with region (East vs. West), voltage (230-kV vs 500-kV), and circuit configuration as strata. There were five different circuit configuration groups for each region/voltage category requiring a total of 200 strata. Magnetic field measurements were taken at 13 locations under each span using an EMDEX-C as a survey meter. Additional information recorded for each span included conductor height (at 10 locations), right-of-way width, longitudinal and lateral slope, time of day, vegetation, terrain, weather conditions, temperature, wind speed, span length and presence of other lines in the corridor. 9 refs., 17 figs., 26 tabs.

  6. Trends of Environmental Technology of Overhead Transmission Line

    NASA Astrophysics Data System (ADS)

    Kubokawa, Hiroshi

    Movement toward extra high voltage and large capacity of overhead transmission line induces problems of wind noise and corona noise to the peripheral areas. Accordingly, environmental concern has become a critical issue of overhead transmission line construction. To reduce environmental impact, low noise overhead conductors have been developed. Meanwhile, as the environmental impact of transmission lines, there is a problem of corrosion due to intrusion of sea salt and acid rain to the inside of the wire. To reduce the environmental impact, corrosion-resistant conductors have been developed. This paper presents various environmental technologies applied to the site and future trends.

  7. Citizens, farmers fight huge transmission lines

    SciTech Connect

    Brummer, J.

    1982-02-01

    Opposition to high tension power lines with a 20-story towers is growing as coalitions of farmers and advocates of safe energy respond with legal intervention and sabotage, and sometimes with success. Examples of citizen action are the efforts opposing a 450 kilovolt direct current line connecting the US with Quebec Hydro and another opposing a 500 kilovolt alternating current line from Georgia Power Co.'s nuclear plants to Florida. The opposition derives partly from evidence of health hazards to humans and adverse effects on livestock. High voltage lines are felt to symbolize a utility and regulatory failure to assess the recent decline in power demand. It is stated that administration efforts to outlaw organized resistence will not deter the opposition, which cites instances of ground shock, aborted and stillborn cattle, physical irritants, and other phenomena. The General Assembly to Stop the Powerline (GASP) objects to the guinea pig position forced upon residents by the utilities. 6 references. (DCK)

  8. Biological studies of swine exposed to 60-Hz electric fields. Volume 4: growth, reproduction, and development. Final report

    SciTech Connect

    Not Available

    1985-12-01

    Swine were exposed to uniform, vertical, 60-Hz, 30-kV/m electric fields for 20 hours/day, 7 days/week. The parental generation (F/sub 0/ gilts) was bred after 4 months on study; some were killed for teratologic study at 100 days of gestation (dg), and the others produced a first-generation (F/sub 1/) of offspring. The pooled incidence of terata in these litters was similar in the exposed and sham-exposed groups. The F/sub 0/ females, which produced the F/sub 1/ generation, were rebred after 18 months of exposure and were killed at 100 dg: malformation incidence in exposed litters (75%) was significantly greater than in sham-exposed litters (29%). Types of malformations were not dissimilar between the two groups. The F/sub 1/ gilts were bred at 18 months of age; there were indications of impaired copulatory behavior and decreased fertility in the exposed animals. Defective offspring were found in significantly more of the exposed litters (71%) than in sham-exposed litters (33%). The F/sub 1/ sows were bred again 10 months later, and teratologic evaluations were performed on their second litters at 100 dg. The percentage of litters with malformed fetuses was essentially identical in the exposed and sham-exposed groups (70 and 73%, respectively). The change in malformation incidences between generations and between the first and second breedings makes it difficult to unequivocally conclude that chronic exposure to a strong electric field caused developmental effects in swine, although it appears there may be an association. It is also possible that other factors, such as housing, inbreeding, disease or its treatment may have contributed to the results. 22 refs., 9 figs., 28 tabs.

  9. Effects of 60 Hz electromagnetic fields on early growth in three plant species and a replication of previous results.

    PubMed

    Davies, M S

    1996-01-01

    In an attempt to replicate the findings of Smith et al., seeds of Raphanus sativus L. (radish), Sinapsis alba L. (mustard), and Hordeum vulgare L. (barley) were grown for between 9 and 21 days in continuous electromagnetic fields (EMFs) at "ion-cyclotron resonance" conditions for stimulation of Ca(2+) (B(H) = 78.3 mu T, B(HAC) = 40 mu T peak-peak at 60 Hz, B(V) = 0). On harvesting, radish showed results similar to those of Smith et al. Dry stem weight and plant height were both significantly greater (Mann-Whitney tests, Ps < 0.05) in EMF-exposed plants than in control plants in each EMF experiment. Wet root weight was significantly greater in EMF-exposed plants in two out of three experiments, as were dry leaf weight, dry whole weight, and stem diameter. Dry root weight, wet leaf weight, and wet whole weight were significantly greater in EMF-exposed plants in one of three experiments. All significant differences indicated an increase in weight or size in the EMF-exposed plants. In each of the sham experiments, no differences between exposed and control plants were evident. Mustard plants failed to respond to the EMFs in any of the plant parameters measured. In one experiment, barley similarly failed to respond; but in another showed significantly greater wet root weight and significantly smaller stem diameter and dry seed weight at the end of the experiment in exposed plants compared to control plants. Although these results give no clue about the underlying bioelectromagnetic mechanism, they demonstrate that, at least for one EMF-sensitive biosystem, results can be independently replicated in another laboratory. Such replication is crucial in establishing the validity of bioelectromagnetic science. PMID:8860733

  10. Effects of 60 Hz electromagnetic fields on early growth in three plant species and a replication of previous results

    SciTech Connect

    Davis, M.S.

    1996-05-01

    In an attempt to replicate the findings of Smith et al., seeds of Raphanus sativus L. (radish), Sinapsis alba L. (mustard), and Hordeum vulgare L. (barley) were grown for between 9 and 21 days in continuous electromagnetic fields (EMFs) at ion-cyclotron resonance conditions for stimulation of Ca{sup 2+} (B{sub H} = 78.3 {micro}T, B{sub HAC} = 40 {micro}T peak-peak at 60 Hz, B{sub v} = 0). On harvesting, radish showed results similar to those of Smith et al. Dry stem weight and plant height were both significantly greater (Mann-Whitney tests, Ps < 0.05) in EMF-exposed plants than in control plants in each EMF experiment. Wet root weight was significantly greater in EMF-exposed plants in two out of three experiments, as were dry leaf weight, dry whole weight, and stem diameter. Dry root weight, wet leaf weight, and wet whole weight were significantly greater in EMF-exposed plants in one of three experiments. All significant differences indicated an increase in weight or size in the EMF-exposed plants. In each of the sham experiments, no differences between exposed and control plants were evident. Mustard plants failed to respond to the EMFs in any of the plant parameters measured. In one experiment, barley similarly failed to respond; but in another showed significantly greater wet root weight and significantly smaller stem diameter and dry seed weight at the end of the experiment in exposed plants compared to control plants. Although these results give no clue about the underlying bioelectromagnetic mechanism, they demonstrate that, at least for one EMF-sensitive biosystem, results can be independently replicated in another laboratory. Such replication is crucial in establishing the validity of bioelectromagnetic science.

  11. Study of the behavioral and biological effects of high-strength 60-Hz electric fields. Quarterly technical progress report number 10, 18 December 1982-18 March 1983

    SciTech Connect

    Not Available

    1983-04-20

    The objective of this contract is to use the baboon as a surrogate for the human in studies of the possible deleterious effects of exposure to high strength, 60 Hz electric fields. The specific aims of this contract are to (1) design and construct an exposure facility in which baboons can be exposed to an electric field up to 60 kV/m in intensity for experiments and (2) to develop computer models relating the fields and currents produced in both baboons and humans by exposure to high strength, 60 Hz electric fields.

  12. Study of the behavioral and biological effects of high-strength 60-Hz electric fields. Quarterly progress report, 11 October 1981-10 January 1982. [Research plan

    SciTech Connect

    Rogers, W.R.

    1982-01-01

    The primary objective of this research is to study the effects of high intensity, 60 Hz electric fields on baboon behavior to obtain information which will assist in the determination of the degree of risk of deleterious consequences for humans exposed to such fields. The generalization of results obtained with the baboon to predictions concerning humans will be aided by the development of computer models relating the surface electric field intensities and internal current densities produced in baboons and humans by exposure to high intensity, 60 Hz electric fields. Research plans are described.

  13. A novel transmission line characterisation based on measurement data reconfirmation

    NASA Astrophysics Data System (ADS)

    Kim, Dongchul; Kim, Hyewon; Eo, Yungseon

    2014-04-01

    Due to inherent resonance effects and frequency-variant dielectric properties, it is very difficult to experimentally determine the stable and accurate circuit model parameters of thin film transmission line structures over a broad frequency band. In this article, a new, simple and straightforward frequency-variant transmission line circuit model parameter determination method is presented. Experimental test patterns for high-frequency transmission line characterisations are designed and fabricated using a package process. The S-parameters for the test patterns are measured using a vector network analyzer (VNA) from 100 MHz to 26.5 GHz. The parasitic effects due to contact pads are de-embedded. The frequency-variant complex permittivity and resonance-effect-free transmission line parameters (i.e., the propagation constant and characteristic impedance) are then determined in a broad frequency band.

  14. Single transmission line interrogated multiple channel data acquisition system

    DOEpatents

    Fasching, George E.; Keech, Jr., Thomas W.

    1980-01-01

    A single transmission line interrogated multiple channel data acquisition system is provided in which a plurality of remote station/sensor circuits each monitors a specific process variable and each transmits measurement values over a single transmission line to a master interrogating station when addressed by said master interrogating station. Typically, as many as 330 remote stations may be parallel connected to the transmission line which may exceed 7,000 feet. The interrogation rate is typically 330 stations/second. The master interrogating station samples each station according to a shared, charging transmit-receive cycle. All remote station address signals, all data signals from the remote stations/sensors and all power for all of the remote station/sensors are transmitted via a single continuous terminated coaxial cable. A means is provided for periodically and remotely calibrating all remote sensors for zero and span. A provision is available to remotely disconnect any selected sensor station from the main transmission line.

  15. Electrical and Biological Effects of Transmission Lines: A Review.

    SciTech Connect

    Lee, Jack M.

    1989-06-01

    This review describes the electrical properties of a-c and d-c transmission lines and the resulting effects on plants, animals, and people. Methods used by BPA to mitigate undesirable effects are also discussed. Although much of the information in this review pertains to high-voltage transmission lines, information on distribution lines and electrical appliances is included. The electrical properties discussed are electric and magnetic fields and corona: first for alternating-current (a-c) lines, then for direct current (d-c).

  16. ANALYSIS AND SIMULATION OF MAIN MAGNET TRANSMISSION LINE EFFECT

    SciTech Connect

    ZHANG,W.; MARNERIS, I.; SANDBERG, J.

    2007-06-25

    A main magnet chain forms a pair of transmission lines. Pulse-reflection-caused voltage and current differentiation throughout the magnet chain can have adverse effect on main magnet field quality. This effect is associated with magnet system configuration, coupling efficiency, and parasitic parameters. A better understanding of this phenomenon will help us in new design and existing system upgrade. In this paper, we exam the transmission line effect due to different input functions as well as configuration, coupling, and other parameters.

  17. Gas insulated transmission line having tapered particle trapping ring

    DOEpatents

    Cookson, Alan H.

    1982-01-01

    A gas-insulated transmission line includes an outer sheath, an inner conductor, insulating supports and an insulating gas. A particle-trapping ring is secured to each insulating support, and it is comprised of a central portion and two tapered end portions. The ends of the particle trapping ring have a smaller diameter than the central portion of the ring, so as to enable the use of the particle trapping ring in a curved transmission line.

  18. Corrugated outer sheath gas-insulated transmission line

    DOEpatents

    Kemeny, George A.; Cookson, Alan H.

    1981-01-01

    A gas-insulated transmission line includes two transmission line sections each of which are formed of a corrugated outer housing enclosing an inner high-voltage conductor disposed therein, with insulating support means supporting the inner conductor within the outer housing and an insulating gas providing electrical insulation therebetween. The outer housings in each section have smooth end sections at the longitudinal ends thereof which are joined together by joining means which provide for a sealing fixed joint.

  19. Five Mass Power Transmission Line of a Ship Computer Modelling

    NASA Astrophysics Data System (ADS)

    Kazakoff, Alexander Borisoff; Marinov, Boycho Ivanov

    2016-03-01

    The work, presented in this paper, appears to be a natural continuation of the work presented and reported before, on the design of power transmission line of a ship, but with different multi-mass model. Some data from the previous investigations are used as a reference data, mainly from the analytical investigations, for the developed in the previ- ous study, frequency and modal analysis of a five mass model of a power transmission line of a ship. In the paper, a profound dynamic analysis of a concrete five mass dynamic model of the power transmission line of a ship is performed using Finite Element Analysis (FEA), based on the previously recommended model, investigated in the previous research and reported before. Thus, the partially validated by frequency analysis five mass model of a power transmission line of a ship is subjected to dynamic analysis. The objective of the work presented in this paper is dynamic modelling of a five mass transmission line of a ship, partial validation of the model and von Mises stress analysis calculation with the help of Finite Element Analysis (FEA) and comparison of the derived results with the analytically calculated values. The partially validated five mass power transmission line of a ship can be used for definition of many dy- namic parameters, particularly amplitude of displacement, velocity and acceleration, respectively in time and frequency domain. The frequency behaviour of the model parameters is investigated in frequency domain and it corresponds to the predicted one.

  20. A Generalized Lossy Transmission-Line Model for Tunable Graphene-Based Transmission Lines with Attenuation Phenomenon

    PubMed Central

    Wu, Yongle; Qu, Meijun; Liu, Yuanan

    2016-01-01

    To investigate the frequency shift phenomenon by inserting graphene, a generalized lossy transmission-line model and the related electrical parameter-extraction theory are proposed in this paper. Three kinds of graphene-based transmission lines with attenuation phenomenon including microstrip line, double-side parallel strip line, and uniplanar coplanar waveguide are analyzed under the common conditions where different chemical potentials are loaded on graphene. The values of attenuation constant and phase constant, and the real and imaginary parts of the characteristic impedance of transmission lines are extracted to analyze in details. When the attenuation constant and the reactance part of the characteristic impedance are approximately equal to zero, this kind of transmission line has low or zero insertion loss. On the contrary, the transmission line is under the radiation mode with obvious insertion loss. The phase constant changes linearly under the transmission mode and can be varied with changing of chemical potentials which attributes to the property of frequency tunability. Furthermore, a bandwidth reconfigurable uniplanar coplanar waveguide power divider is simulated to demonstrate that this theory can be applied to the design of three-port devices. In summary, this work provides a strong potential approach and design theory to help design other kinds of terahertz and mid-infrared reconfigurable devices. PMID:27553759

  1. A Generalized Lossy Transmission-Line Model for Tunable Graphene-Based Transmission Lines with Attenuation Phenomenon.

    PubMed

    Wu, Yongle; Qu, Meijun; Liu, Yuanan

    2016-01-01

    To investigate the frequency shift phenomenon by inserting graphene, a generalized lossy transmission-line model and the related electrical parameter-extraction theory are proposed in this paper. Three kinds of graphene-based transmission lines with attenuation phenomenon including microstrip line, double-side parallel strip line, and uniplanar coplanar waveguide are analyzed under the common conditions where different chemical potentials are loaded on graphene. The values of attenuation constant and phase constant, and the real and imaginary parts of the characteristic impedance of transmission lines are extracted to analyze in details. When the attenuation constant and the reactance part of the characteristic impedance are approximately equal to zero, this kind of transmission line has low or zero insertion loss. On the contrary, the transmission line is under the radiation mode with obvious insertion loss. The phase constant changes linearly under the transmission mode and can be varied with changing of chemical potentials which attributes to the property of frequency tunability. Furthermore, a bandwidth reconfigurable uniplanar coplanar waveguide power divider is simulated to demonstrate that this theory can be applied to the design of three-port devices. In summary, this work provides a strong potential approach and design theory to help design other kinds of terahertz and mid-infrared reconfigurable devices. PMID:27553759

  2. Effects of 60 Hz Magnetic Field Exposure on the Pineal and Hypothalamic-Pituitary-Gonadal Axis in the Siberian Hamster (Phodopus Sungorus)

    SciTech Connect

    Wilson, Bary W.); Matt, Kathleen S.; Morris, James E.); Sasser, Lyle B.); Miller, Douglas L.); Anderson, Larry E.)

    1999-11-15

    Experiments using the dwarf Siberian hamster Phodopus sungorus were carried out to determine possible neuroendocrine consequences of one-time and repeated exposures to 60 Hz magnetic fields (MF). Animals were maintained in either a short-light (SL, 8 h light:16 h dar) or long-light (LL, 16 h light:8h dark) photoperiod.

  3. Experimental Analysis of Reduced-Sized Coplanar Waveguide Transmission Lines

    NASA Technical Reports Server (NTRS)

    Ponchak, George E.

    2002-01-01

    An experimental investigation of the use of capacitive loading of coplanar waveguides to reduce their line length and, thus the size, of monolithic microwave integrated circuits is presented. The reduced sized coplanar waveguides are compared to unloaded transmission lines and to lumped element transmission line segments. The phase bandwidth, defined by 2 percent error in S(sub 21), and the return loss bandwidth, defined by a return loss greater than 15 dB, of coplanar waveguides reduced from 0 to 90 percent are compared, and the insertion loss as a function of the size reduction is presented.

  4. Stand-off transmission lines and method for making same

    DOEpatents

    Tuckerman, David B.

    1991-01-01

    Standoff transmission lines in an integrated circuit structure are formed by etching away or removing the portion of the dielectric layer separating the microstrip metal lines and the ground plane from the regions that are not under the lines. The microstrip lines can be fabricated by a subtractive process of etching a metal layer, an additive process of direct laser writing fine lines followed by plating up the lines or a subtractive/additive process in which a trench is etched over a nucleation layer and the wire is electrolytically deposited. Microstrip lines supported on freestanding posts of dielectric material surrounded by air gaps are produced. The average dielectric constant between the lines and ground plane is reduced, resulting in higher characteristic impedance, less crosstalk between lines, increased signal propagation velocities, and reduced wafer stress.

  5. NOVEL SIGNAL PROCESSING WITH NONLINEAR TRANSMISSION LINES

    SciTech Connect

    D. REAGOR; ET AL

    2000-08-01

    Nonlinear dielectrics offer uniquely strong and tunable nonlinearities that make them attractive for current devices (for example, frequency-agile microwave filters) and for future signal-processing technologies. The goal of this project is to understand pulse propagation on nonlinear coplanar waveguide prototype devices. We have performed time-domain and frequency-domain experimental studies of simple waveguide structures and pursued a theoretical understanding of the propagation of signals on these nonlinear waveguides. To realistically assess the potential applications, we used a time-domain measurement and analysis technique developed during this project to perform a broadband electrodynamics characterization in terms of nonlinear, dispersive, and dissipative effects. We completed a comprehensive study of coplanar waveguides made from high-temperature superconducting thin-film YBa{sub 2}Cu{sub 3}O{sub 7{minus}{delta}} electrodes on nonlinear dielectric single-crystal SrTiO{sub 3} substrates. By using parameters determined from small-signal (linear) transmission characteristics of the waveguides, we develop a model equation that successfully predicts and describes large-signal (nonlinear) behavior.

  6. Electric transmission line flashover prediction system

    NASA Astrophysics Data System (ADS)

    Amarh, Felix

    Near industrial, agricultural, or coastal areas, contamination is a frequent cause of insulator flashover, most cases of which result in lengthy service interruptions. Utilities spend significant amounts of money on insulator washing and cleaning before the restoration of the service. Laboratory studies and industrial experience have shown that both contamination and wetting of insulator surfaces, which initiate the flow of leakage current, are required for insulator flashover. The leakage current leading to flashover has distinctive stages of development. Flashover is preceded by dry-band arcing and extension of the arc to bridge the insulator. This combination significantly modifies both the magnitude and shape of the leakage current. A condition-based monitoring (CBM) system that monitors the easily measurable insulator leakage current as a means of assessing pollution severity and would possibly predict an approaching flashover could prove beneficial to utilities. The overall aim of this project is the development of a system that monitors pollution build-up through the signature changes in the leakage current and alerts an operator when there is a danger of flashover. The operator can, in turn, order maintenance personnel to wash the insulators. This will safeguard against unforeseen flashovers, since the system is constantly being monitored and diagnosed. Additionally, the washing cycles of insulators will be optimized, saving money and eventually rendering the power transmission system more reliable.

  7. Atlas Transmission Line/Transition Design and Fabrication Status

    SciTech Connect

    Ballard, E.O.; Baca, D.M.; Davis, H.A.; Elizondo, J.M.; Gribble, R.F.; Nielsen, K.E.; Parker, G.V.; Ricketts, R.L.; Valdez, G.

    1999-06-27

    Atlas is a pulsed-power facility under development at Los Alamos National Laboratory to drive high-energy density experiments. Design has been completed for this new generation pulsed-power machine consisting of an azimuthal array of 24, 240-kV Marx modules and transmission lines supplying current to the load region at the machine center. The transmission line consists of a cable header, load protection switch, and tri-plate assembly interfacing to the center transition section. The cable header interface to the Marx module provides a mechanism to remove the Marx module for maintenance without removing other components of the transmission line. The load protection switch provides a mechanism for protecting the load during charging of the Marx in the event of a pre-fire condition. The aluminum tri-plate is a low-inductance transmission line carries radial current flow from the Marx energy storage system at the machine periphery toward the load. All transmission line components are oil insulated except the solid-dielectric insulated power flow channel connected directly to the load. The transition region at the machine center consists of several components that enable the radial converging vertical transmission lines to interface to a horizontal disk/conical power flow channel delivering current to the load. The current carrying transition components include the high-voltage and ground conductors interfacing to the tri-plate transmission lines. The tri-plate tank attachment ring interfaces to the tri-plate tanks and the base-plate. The base-plate supports the transition components and interfaces to the center support structure of the machine. The bottom insulator also attaches to the base-plate and to the high-voltage conductor, providing an oil containment seal between the transition and vacuum vessel. Design has been completed for all Atlas components. Some prototype hardware fabrication has been completed and first article hardware is in various stages of

  8. Artificial neural network modeling of plasmonic transmission lines.

    PubMed

    Andrawis, Robert R; Swillam, Mohamed A; El-Gamal, Mohamed A; Soliman, Ezzeldin A

    2016-04-01

    In this paper, new models based on an artificial neural network (ANN) are developed to predict the propagation characteristics of plasmonic nanostrip and coupled nanostrips transmission lines. The trained ANNs are capable of providing the required propagation characteristics with good accuracy and almost instantaneously. The nonlinear mapping performed by the trained ANNs is written as closed-form expressions, which facilitate the direct use of the results obtained in this research. The propagation characteristics of the investigated transmission lines include the effective refractive index and the characteristic impedance. The time needed to simulate 1000 different versions of the transmission line structure is about 48 h, using a full-wave electromagnetic solver compared to 3 s using the developed ANN model. PMID:27139685

  9. Residential proximity to high voltage transmission lines and depressive symptomatology

    SciTech Connect

    McMahan, S.G.

    1992-01-01

    A number of epidemiological studies indicate an association between depression and proximity to high voltage transmission lines. These studies have been criticized, however, for using surrogate measures of electromagnetic fields (EMFs) and unstandardized measures of depression. In an effort to overcome these limitations, the Center for Epidemiological Studies Depression (CES-D) scale was administered to 152 women living either adjacent to a transmission line or one block away. Results indicate that homes adjacent to the transmission lines have an average EMF level of 4.86 milligauss at their front door and those one block away have an average of 0.68 milligauss. There was no significant difference in CES-D scores between the groups, controlling for demographic variables. There appeared to be an increase in other health effects, including cancer and miscarriages, but these findings were preliminary and need further investigation.

  10. Quasi-Optical Transmission Line for 94-GHz Radar

    NASA Technical Reports Server (NTRS)

    Perez, Raul M.; Veruttipong, Watt

    2008-01-01

    A quasi-optical transmission line (QOTL) has been developed as a low-loss transmission line for a spaceborne cloudobserving radar instrument that operates at a nominal frequency of 94 GHz. This QOTL could also readily be redesigned for use in terrestrial millimeter-wave radar systems and millimeter-wave imaging systems. In the absence of this or another lowloss transmission line, it would be necessary to use a waveguide transmission line in the original radar application. Unfortunately, transmission losses increase and power-handling capacities of waveguides generally decrease with frequency, such that at 94 GHz, the limitation on transmitting power and the combined transmission and reception losses (greater than 5 dB) in a waveguide transmission line previously considered for the original application would be unacceptable. The QOTL functions as a very-lowloss, three-port circulator. The QOTL includes a shaped input mirror that can be rotated to accept 94-GHz transmitter power from either of two high-power amplifiers. Inside the QOTL, the transmitter power takes the form of a linearly polarized beam radiated from a feed horn. This beam propagates through a system of mirrors, each of which refocuses the beam to minimize diffraction losses. A magnetically biased ferrite disc is placed at one of the foci to utilize the Faraday effect to rotate the polarization of the beam by 45 degrees. The beam is then transmitted via an antenna system. The radar return (scatter from clouds, and/or reflections from other objects) is collected by the same antenna and propagates through the Faraday rotator in the reverse of the direction of propagation of the transmitted beam. In the Faraday rotator, the polarization of the received signal is rotated a further 45 degrees, so that upon emerging from the Faraday rotator, the received beam is polarized at 90 with respect to the transmitted beam. The transmitted and received signals are then separated by a wire-grid polarizer.

  11. Self-monitoring high voltage transmission line suspension insulator

    DOEpatents

    Stemler, Gary E.; Scott, Donald N.

    1981-01-01

    A high voltage transmission line suspension insulator (18 or 22) which monitors its own dielectric integrity. A dielectric rod (10) has one larger diameter end fitting attachable to a transmission line and another larger diameter end fitting attachable to a support tower. The rod is enclosed in a dielectric tube (14) which is hermetically sealed to the rod's end fittings such that a liquidtight space (20) is formed between the rod and the tube. A pressurized dielectric liquid is placed within that space. A discoloring dye placed within this space is used to detect the loss of the pressurized liquid.

  12. Gates to Gregg High Voltage Transmission Line Study. [California

    NASA Technical Reports Server (NTRS)

    Bergis, V.; Maw, K.; Newland, W.; Sinnott, D.; Thornbury, G.; Easterwood, P.; Bonderud, J.

    1982-01-01

    The usefulness of LANDSAT data in the planning of transmission line routes was assessed. LANDSAT digital data and image processing techniques, specifically a multi-date supervised classification aproach, were used to develop a land cover map for an agricultural area near Fresno, California. Twenty-six land cover classes were identified, of which twenty classes were agricultural crops. High classification accuracies (greater than 80%) were attained for several classes, including cotton, grain, and vineyards. The primary products generated were 1:24,000, 1:100,000 and 1:250,000 scale maps of the classification and acreage summaries for all land cover classes within four alternate transmission line routes.

  13. Reconfigurable Wave Velocity Transmission Lines for Phased Arrays

    NASA Technical Reports Server (NTRS)

    Host, Nick; Chen, Chi-Chih; Volakis, John L.; Miranda, Felix

    2013-01-01

    Phased array antennas showcase many advantages over mechanically steered systems. However, they are also more complex, heavy and most importantly costly. This presentation paper presents a concept which overcomes these detrimental attributes by eliminating all of the phase array backend (including phase shifters). Instead, a wave velocity reconfigurable transmission line is used in a series fed array arrangement to allow phase shifting with one small (100mil) mechanical motion. Different configurations of the reconfigurable wave velocity transmission line are discussed and simulated and experimental results are presented.

  14. Mechanism of biological effects observed in honey bees (Apis mellifera, L. ) hived under extra-high-voltage transmission lines: implications derived from bee exposure to simulated intense electric fields and shocks

    SciTech Connect

    Bindokas, V.P.; Gauger, J.R.; Greenberg, B.

    1988-01-01

    This work explores mechanisms for disturbance of honey bee colonies under a 765 kV, 60-Hz transmission line (electric (E) field = 7 kV/m) observed in previous studies. Proposed mechanisms fell into two categories: direct bee perception of enhanced in-hive E fields and perception of shock from induced currents. The adverse biological effects could be reproduced in simulations where only the worker bees were exposed to shock or to E field in elongated hive entranceways (= tunnels). We now report the results of full-scale experiments using the tunnel exposure scheme, which assesses the contribution of shock and intense E field to colony disturbance. Exposure of worker bees (1400 h) to 60-Hz E fields including 100 kV/m under moisture-free conditions within a nonconductive tunnel causes no deleterious affect on colony behavior. Exposure of bees in conductive (e.g., wet) tunnels produces bee disturbance, increased mortality, abnormal propolization, and possible impairment of colony growth. We propose that this substrate dependence of bee disturbance is the result of perception of shock from coupled body currents and enhanced current densities postulated to exist in the legs and thorax of bees on conductors. Similarly, disturbance occurs when bees are exposed to step-potential-induced currents. At 275-350 nA single bees are disturbed; at 600 nA bees begin abnormal propolization behavior; and stinging occurs at 900 nA. We conclude that biological effects seen in bee colonies under a transmission line are primarily the result of electric shock from induced hive currents. This evaluation is based on the limited effects of E-field exposure in tunnels, the observed disturbance thresholds caused by shocks in tunnels, and the ability of hives exposed under a transmission line to source currents 100-1,000 times the shock thresholds.

  15. Effects of a 30 kV/m, 60 Hz electric field on the social behavior of baboons: A crossover experiment

    SciTech Connect

    Easley, S.P.; Coelho, A.M. Jr.; Rogers, W.R. )

    1992-01-01

    Using a crossover experimental design, we evaluated our earlier findings that exposure to a 30 kV/m, 60 Hz electric field for 12 hours per day, 7 days per week for 6 weeks produced significant changes in the performance rates of social behaviors among young adult male baboons. In the crossover experiment, the former control group was exposed to a 30 kV/m, 60 Hz electric field for 3 weeks. Only an extremely small, incidental magnetic field was generated by the exposure apparatus. We found that electric-field exposure again produced increases in the performance rates that index Passive Affinity, Tension, and Stereotypy. These findings, combined with results from our other electric-field experiments, indicate that exposure to strong electric fields, in the absence of associated magnetic fields, consistently produces effects that are expressed as increases in rates of performance of social behaviors in young adult male baboons.

  16. Transmission Lines: An Overview of Electrical Properties and Environmental Effects.

    SciTech Connect

    United States. Bonneville Power Administration. Biological Studies Task Team.

    1982-03-01

    A brief overview is provided of environmental and biological effects of high-voltage power transmission lines. Paragraph length descriptions of electric fields, induced voltage and currents, biological effects, magnetic fields, corona, radio and television interference, and ozone are given. 13 figs.

  17. 77 FR 35366 - Albany-Eugene Transmission Line Rebuild Project

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-13

    ... Administration (BPA), Department of Energy (DOE). ACTION: Notice of Availability of Record of Decision (ROD..., based on the Albany-Eugene Transmission Line Rebuild Project (DOE/EIS-0457, March 2012). BPA has decided... will continue to operate at 115 kV. ADDRESSES: Copies of the ROD and EIS may be obtained by calling...

  18. Flow Impedance in a Uniform Magnetically-Insulated Transmission Line

    SciTech Connect

    Mendel, C.W.

    1999-03-23

    In two recent publications relativistic electron flow in cylindrical magnetically-insulated transmission lines (MITL) was analyzed and modeled under the assumption of negligible electron pressure. Cylindrical MITLs were used because of their common occurrence, and because they are the simplest case of finite width. The authors show in this report that the models apply equally to MITLs of any cross section.

  19. High voltage gas insulated transmission line with continuous particle trapping

    DOEpatents

    Cookson, Alan H.; Dale, Steinar J.

    1983-01-01

    This invention provides a novel high voltage gas insulated transmission line utilizing insulating supports spaced at intervals with snap-in means for supporting a continuous trapping apparatus and said trapping apparatus having perforations and cutouts to facilitate trapping of contaminating particles and system flexibility.

  20. HIGH FREQUENCY POWER TRANSMISSION LINE FOR CYCLOTRONS AND THE LIKE

    DOEpatents

    Armstrong, W.J.

    1954-04-20

    High-frequency power transmission systems, particularly a stacked capacitance alternating power current transmission line wherein maximum utilization of the effective conductios skin of the line conductors is achieved while enabling a low impedance to be obtained are reported. The transmission line consists of a number of flat metal strips with interleaved dielectric strips. The metal dielectric strips are coiled spirally with the axis of the spiral extending along the length of the strips, and the alternating metal strips at the output end have outwardly extending aligned lugs which are directly strapped together and connected to the respective terminals on the load. At the input end of the transmission line, similarly, the alternate metal strips are directly strapped together and connected to an altereating current source. With the arrangement described each metal strip conducts on both sides, so that the metal strips are designed to have a thickness corresponding to twice the depth of the "skin effect" conducting lamina of each conductor at the source frequency.

  1. Airplane Ice Detector Based on a Microwave Transmission Line

    NASA Technical Reports Server (NTRS)

    Ngo, Phong; Arndt, G. Dickey; Carl, James R.

    2004-01-01

    An electronic instrument that could detect the potentially dangerous buildup of ice on an airplane wing is undergoing development. The instrument is based on a microwave transmission line configured as a capacitance probe: at selected spots, the transmission-line conductors are partly exposed to allow any ice and/or liquid water present at those spots to act as predominantly capacitive electrical loads on the transmission line. These loads change the input impedance of the transmission line, as measured at a suitable excitation frequency. Thus, it should be possible to infer the presence of ice and/or liquid water from measurements of the input impedance and/or electrical parameters related to the input impedance. The sensory transmission line is of the microstrip type and thus thin enough to be placed on an airplane wing without unduly disturbing airflow in flight. The sensory spots are small areas from which the upper layer of the microstrip has been removed to allow any liquid water or ice on the surface to reach the transmission line. The sensory spots are spaced at nominal open-circuit points, which are at intervals of a half wavelength (in the transmission line, not in air) at the excitation frequency. The excitation frequency used in the experiments has been 1 GHz, for which a half wavelength in the transmission line is .4 in. (.10 cm). The figure depicts a laboratory prototype of the instrument. The impedance-related quantities chosen for use in this version of the instrument are the magnitude and phase of the scattering parameter S11 as manifested in the in-phase (I ) and quadrature (Q) outputs of the phase detector. By careful layout of the transmission line (including the half-wavelength sensor spacing), one can ensure that the amplitude and phase of the input to the phase detector keep shifting in the same direction as ice forms on one or more of the sensor areas. Although only one transmission-line sensor strip is used in the laboratory version, in a

  2. Sliding backshorts for planar circuits. [strip transmission line tuning

    NASA Technical Reports Server (NTRS)

    Lubecke, Victor M.; Rutledge, David B.; Mcgrath, William R.

    1991-01-01

    An adjustable planar imbedding circuit based on coplanar transmission lines is presented to deal with the impedance mismatch associated with the use of the Superconductor-Insulator-Superconductor tunnel junction. The planar embedding circuit is developed with movable noncontacting shorting elements that consist of thin metallic plates with optimized arrangements of rectangular holes. The rectangular holes are placed along the insulated metallic transmission line to provide a periodic variation of the line impedance. A large reflection coefficient is demonstrated with a scale model of the sliding backshort, and values of more than -0.5 dB are reported. The shorting elements are incorporated into a low-frequency tuning circuit to test the practical tuning ranges. The backshort can be used to fashion tuning stubs with variable post-fabrication electrical lengths which relaxes the design constraints of planar integrated circuits.

  3. Modeling the axial extension of a transmission line source within iterative reconstruction via multiple transmission sources.

    PubMed

    Bowsher, J E; Tornai, M P; Peter, J; González Trotter, D E; Krol, A; Gilland, D R; Jaszczak, R J

    2002-03-01

    Reconstruction algorithms for transmission tomography have generally assumed that the photons reaching a particular detector bin at a particular angle originate from a single point source. In this paper, we highlight several cases of extended transmission sources, in which it may be useful to approach the estimation of attenuation coefficients as a problem involving multiple transmission point sources. Examined in detail is the case of a fixed transmission line source with a fan-beam collimator. This geometry can result in attenuation images that have significant axial blur. Herein it is also shown, empirically, that extended transmission sources can result in biased estimates of the average attenuation, and an explanation is proposed. The finite axial resolution of the transmission line source configuration is modeled within iterative reconstruction using an expectation-maximization algorithm that was previously derived for estimating attenuation coefficients from single photon emission computed tomography (SPECT) emission data. The same algorithm is applicable to both problems because both can be thought of as involving multiple transmission sources. It is shown that modeling axial blur within reconstruction removes the bias in the average estimated attenuation and substantially improves the axial resolution of attenuation images. PMID:11989845

  4. A transmission line bridge for the diagnostics of plasma channels

    NASA Astrophysics Data System (ADS)

    Pechacek, R. E.; Raleigh, M.; Greig, J. R.; Dwyer, T.; Ehrlich, J.

    1984-03-01

    This paper describes a device for measuring the average electrical conductivity of a long, narrow, cylindrical plasma. Interest in plasmas of this shape originates from two areas of study: the study of electron beam propagation through neutral gas, and the study of long straight electrical discharges for use as a communication antenna. Propagation of an electron beam through a neutral gas produces an ionized channel whose properties and evolution are very important to the propagation of the beam itself. Long straight electrical discharges are created in a channel that is ionized by a pulsed laser beam focused with a long focal length lens, and the properties of the plasma in this channel are important to the propagation of the electrical discharge along with channel. The properties of these plasmas are inferred from changes in the transmission properties of a transmission line placed close to and parallel to the plasma. In this paper an analysis is made of the relation between the bridge output voltage and the conductivity of the perturbing plasma for the case in which the conductivity is very low. In this case all perturbations on the bridge parameters are small, and linear approximations are appropriate. The usefulness of the bridge, however, extends to plasma well above this low conductivity range, although a different set of approximations may be necessary to make the analysis of the experiment tractable. A transmission line bridge is a device for measuring very small changes in the properties of transmission lines.

  5. Comparison of Transmission Line Methods for Surface Acoustic Wave Modeling

    NASA Technical Reports Server (NTRS)

    Wilson, William; Atkinson, Gary

    2009-01-01

    Surface Acoustic Wave (SAW) technology is low cost, rugged, lightweight, extremely low power and can be used to develop passive wireless sensors. For these reasons, NASA is investigating the use of SAW technology for Integrated Vehicle Health Monitoring (IVHM) of aerospace structures. To facilitate rapid prototyping of passive SAW sensors for aerospace applications, SAW models have been developed. This paper reports on the comparison of three methods of modeling SAWs. The three models are the Impulse Response Method (a first order model), and two second order matrix methods; the conventional matrix approach, and a modified matrix approach that is extended to include internal finger reflections. The second order models are based upon matrices that were originally developed for analyzing microwave circuits using transmission line theory. Results from the models are presented with measured data from devices. Keywords: Surface Acoustic Wave, SAW, transmission line models, Impulse Response Method.

  6. Beam coupling impedances of fast transmission-line kickers.

    SciTech Connect

    Kurennoy, S.

    2002-01-01

    Fast transmission-line kickers contain no ferrite and consist of two long metallic parallel plates supported by insulators inside a beam pipe. A beam is deflected by both the electric and magnetic fields of a TEM wave created by a pulse propagating along the strips in the direction opposite to the beam. Computations of the beam coupling impedances for such structures are difficult because of their length. In the paper, the beam coupling impedances of transmission-line kickers are calculated by combining analytical and numerical methods: the wake potentials computed in short models are extended analytically to obtain the wakes for the long kickers, and then the corresponding beam impedances are derived. At very low frequencies the results are compared with simple analytical expressions for the coupling impedances of striplines in beam position monitors.

  7. Flow impedance in a uniform magnetically insulated transmission line

    NASA Astrophysics Data System (ADS)

    Mendel, C. W.; Seidel, D. B.

    1999-12-01

    In two recent publications [C. W. Mendel, Jr. and S. E. Rosenthal, Phys. of Plasmas 2, 1332 (1995), C. W. Mendel, Jr. and S. E. Rosenthal, Phys. of Plasmas 3, 4207 (1996)] relativistic electron flow in cylindrical magnetically insulated transmission lines was analyzed and modeled under the assumption of negligible electron pressure. The model allows power flow in these lines to be accurately calculated under most conditions. The model was developed for coaxial right circular cylindrical electrodes. It is shown here that the model applies equally well to arbitrary cylindrical systems, i.e., systems consisting of electrodes of arbitrary cross section.

  8. Flow impedance in a uniform magnetically insulated transmission line

    SciTech Connect

    Mendel, C.W. Jr.; Seidel, D.B.

    1999-12-01

    In two recent publications [C. W. Mendel, Jr. and S. E. Rosenthal, Phys. of Plasmas {bold 2}, 1332 (1995), C. W. Mendel, Jr. and S. E. Rosenthal, Phys. of Plasmas {bold 3}, 4207 (1996)] relativistic electron flow in cylindrical magnetically insulated transmission lines was analyzed and modeled under the assumption of negligible electron pressure. The model allows power flow in these lines to be accurately calculated under most conditions. The model was developed for coaxial right circular cylindrical electrodes. It is shown here that the model applies equally well to arbitrary cylindrical systems, i.e., systems consisting of electrodes of arbitrary cross section. {copyright} {ital 1999 American Institute of Physics.}

  9. Reconfigurable Wave Velocity Transmission Lines for Phased Arrays

    NASA Technical Reports Server (NTRS)

    Host, Nicholas Keith; Chen, Chi-Chih; Volakis, John L.

    2012-01-01

    This presentation discussed a novel phased array with an emphasis to simplify the array feed. Specifically, we will demonstrate a simple, low cost feeding approach by mechanically controlling the substrate thickness. The array feed lines are constructed from parallel plate transmission lines whose thickness are adjusted to control their effective dielectric constant (Epsilon_eff). As a result the phase delay/excitation at each array element will be adjusted per desired beam direction. The proposed antenna elements will be overlapping dipoles operating over a 2:1 bandwidth in the Ku-Band spectrum. Preliminary simulation and experimental demonstration of such an array will be presented.

  10. HTS DC Transmission Line for Megalopolis Grid Development

    NASA Astrophysics Data System (ADS)

    Kopylov, S.; Sytnikov, V.; Bemert, S.; Ivanov, Yu; Krivetskiy, I.; Romashov, M.; Shakaryan, Yu; Keilin, V.; Shikov, A.; Patrikeev, V.; Lobyntsev, V.; Shcherbakov, V.

    2014-05-01

    Using of HTS AC and DC cables in electric power grids allows increasing of the transferred power, losses diminishing, decreasing of exclusion zone areas, the enhancement of the environmental conditions and fire/explosion safety of electric power systems. However, the use of DC superconducting cable lines together with converters brings additional advantages as reduction of losses in cables and suitable lowering of refrigerating plant capacity, as well as the realization of the function of short-circuit currents limitation by means of the appropriate setting of converter equipment. Russian Federal Grid Company and its R&D Center started the construction of the DC HTS power transmission line which includes the cable itself, cryogenic equipment, AC/DC converters, terminals and cable coupling boxes. This line will connect two substations in Saint-Petersburg - 330 kV "Centralnaya" and 220 kV "RP-9". The length of this HTS transmission line will be about 2500 meters. Nowadays are developed all the elements of the line and technologies of the cable manufacturing. Two HTS cable samples, each 30 m length, have been made. This paper describes the results of cables tests.

  11. Nonlinear waves propagating in the electrical transmission line

    NASA Astrophysics Data System (ADS)

    Duan, W.-S.

    2004-04-01

    A coupled Zakharov-Kuznetsov (ZK) equation is derived for a nonlinear transmission line in which the nonlinear capacitance C is of a general form C = C0(1 + k1V + k2V2 + ...). For a solitary-wave solution of the ZK equation, there is an instability region which is given numerically in this paper. It is in agreement with the analytical results for special cases.

  12. Parameters of lossless transmission lines with spherical T-waves

    NASA Astrophysics Data System (ADS)

    Kniaz, A. I.; Draganov, V. M.

    1983-04-01

    The analogy between plane-parallel and spherical-parallel fields is used to derive a unified formula for the parameters (capacitance and wave resistance) of a cylindrical system of conductors with a plane transverse wave and of a system of conical conductors with a spherical transverse wave. This makes it possible to transform previously developed formulas into formulas for determining the parameters of lossless transmission lines with spherical transverse waves. Some examples of the application of the proposed approach are considered.

  13. Gas insulated transmission line with insulators having field controlling recesses

    DOEpatents

    Cookson, Alan H.; Pederson, Bjorn O.

    1984-01-01

    A gas insulated transmission line having a novel insulator for supporting an inner conductor concentrically within an outer sheath. The insulator has a recess contiguous with the periphery of one of the outer and inner conductors. The recess is disposed to a depth equal to an optimum gap for the dielectric insulating fluid used for the high voltage insulation or alternately disposed to a large depth so as to reduce the field at the critical conductor/insulator interface.

  14. Investigation of effects of 60-Hz electric and magnetic fields on operant and social behavior and on the neuroendocrine system of nonhuman primates

    SciTech Connect

    Rogers, W.R.; Rhodes, J.W.

    1992-09-01

    A cohort of sixteen male baboons were assigned to electric and magnetic field (E/MF) exposure and sham-exposure. The social behavior subjects were simultaneously exposed to 60 Hz E/MF. Ten behavioral categories were measured. Each behavioral category was comprised of multiple molecular behaviors that could be objectively identified and counted. Six of the behavior categories were social'', in that interactions between subjected were involved. The remaining four were non-social'' and pertained to individual behaviors such as movements or postural stances.

  15. Mitigation of bird collisions with transmission lines: Final report

    SciTech Connect

    Beaulaurier, D.L.

    1981-09-11

    In this study removal of overhead groundwires was evaluated as a technique for mitigating bird collisions with transmission lines. Groundwires were removed by BPA from a 500 kV double circuit line at Bybee Lake in Portland, Oregon. Earlier studies at these sites had documented small but measurable collision rates (i.e., No. collisions/No. flights) attributed primarily to collisions with groundwires. Observations of bird flights and searches for dead birds in the vicinity of the lines constituted the primary methods of data collection during pre- and post-removal studies. Field work was conducted from October 1980 through March 1981. A total of seven dead birds and eight feather spots were found after groundwire removal. Species found were green-winged teal, pintail, greater scaup, American wigeon, glaucous-winged gull, starling, red-winged blackbird and song sparrow. No collisions with transmission lines were observed. During pre-removal studies at these two sites, a total of 53 dead birds and 22 feather spots were found over two years of study. It was necessary to document flight intensity (No. flights/day) during pre- and post-removal studies, in order to determine if the number of dead birds found changed because of groundwire removal or simply because of changes in flight intensity. 41 refs., 18 figs., 22 tabs.

  16. Dynamic modeling of magnetically insulated transmission line systems

    SciTech Connect

    Mendel, C.W. Jr.; Rosenthal, S.E.

    1996-11-01

    Negative conductors in vacuum transmission lines used in multiterrawatt applications emit electrons freely. These lines are efficient only because the self-magnetic field of the power flow forces the electrons to flow parallel to the electrodes. Excepting numerical simulations, dynamic modeling of systems of these transmission lines has generally either ignored electron flow, or has included only those electrons that cross immediately to the anode at the front of the forward wave. In this paper we describe an analytic model that includes flowing electrons and the effects of these flows on line voltage and on the reduction of magnetic flux. Axial electron currents are modeled using simple, measurable, and calculable parameters. Transverse electron currents are modeled using general patterns found empirically from simulation data. These currents are in turn related by an expanded set of Telegrapher equations. An example of the use of the model is compared to two-dimensional, time-dependent particle-in-cell simulations. {copyright} {ital 1996 American Institute of Physics.}

  17. Exposure of baboons to combined 60 Hz electric and magnetic fields does not produce work stoppage or affect operant performance on a match-to-sample task

    SciTech Connect

    Orr, J.L.; Rogers, W.R.; Smith, H.D.

    1995-12-31

    The authors examined the effects of combined 60 Hz electric and magnetic field (EMF) exposure on performance of delayed match-to-sample (MTS) procedure involving the flash rate of a light as the stimulus. Six baboons (Papio cynocephalus) fully acquired the task; four others functioned accurately only when cued. All ten subjects were assigned to EMF-exposed or sham-exposed groups of five and were used to test for a work-stoppage effect that was previously observed with initial exposure to electric fields (EF) of 30 or 60 kV/m. Here, the authors report the results of two experiments, each consisting of 6 week preexposure, exposure, and postexposure periods. They found no evidence of work stoppage with fields of 6 kV/m and 50 {micro}T (0.5 G) or with 30 kV/m and 100 {micro}T (1.0 G). In neither experiment was there evidence of an adverse effect of 60 Hz EMF exposure on MTS performance.

  18. Regularly scheduled, day-time, slow-onset 60 Hz electric and magnetic field exposure does not depress serum melatonin concentration in nonhuman primates

    SciTech Connect

    Rogers, W.R.; Smith, H.D.; Orr, J.L.; Reiter, R.J.; Barlow-Walden, L.

    1995-12-31

    Experiments conducted with laboratory rodents indicate that exposure to 60 Hz electric fields or magnetic fields can suppress nocturnal melatonin concentrations in pineal gland and blood. In three experiments employing three field-exposed and three sham-exposed nonhuman primates, each implanted with an indwelling venous cannula to allow repeated blood sampling, the authors studied the effects of either 6 kV/m and 50 {micro}T (0.5 G) or 30 kV/m and 100 {micro}T (1.0 G) on serum melatonin patterns. The fields were ramped on and off slowly, so that no transients occurred. Extensive quality control for the melatonin assay, computerized control and monitoring of field intensities, and consistent exposure protocols were used. No changes in nocturnal serum melatonin concentration resulted from 6 weeks of day-time exposure with slow field onset/offset and a highly regular exposure protocol. These results indicate that, under the conditions tested, day-time exposure to 60 Hz electric and magnetic fields in combination does not result in melatonin suppression in primates.

  19. Rapid-onset/offset, variably scheduled 60 Hz electric and magnetic field exposure reduces nocturnal serum melatonin concentration in nonhuman primates

    SciTech Connect

    Rogers, W.R.; Smith, H.D.; Reiter, R.J.; Barlow-Walden, L.

    1995-12-31

    Experiments with rodents indicate that power-frequency electric field (EF) or magnetic field (MF) exposure can suppress the normal nocturnal increase in melatonin concentration in pineal gland and blood. In a separate set of three experiments conducted with nonhuman primates, the authors did not observe melatonin suppression as a result of 6 weeks of day-time exposure to combined 60 Hz electric and magnetic fields (E/MF) with regularly schedule ``slow`` E/MF onsets/offsets. The study described here used a different exposure paradigm in which two baboons were exposed to E/MF with ``rapid`` E/MF onsets/offsets accompanied by EF transients not found with slowly ramped E/MF onset/offset; profound reductions in nocturnal serum melatonin concentration were observed in this experiment. If replicated in a more extensive experiment, the observation of melatonin suppression only in the presence of E/MF transients would suggest that very specific exposure parameters determine the effects of 60 Hz E/MF on melatonin.

  20. Radiofrequency transmission line for bioluminescent Vibrio sp. irradiation

    NASA Astrophysics Data System (ADS)

    Nassisi, V.; Alifano, P.; Talà, A.; Velardi, L.

    2012-07-01

    We present the study and the analyses of a transmission line for radiofrequency (RF) irradiation of bacteria belonging to Vibrio harveyi-related strain PS1, a bioluminescent bacterium living in symbiosis with many marine organisms. The bioluminescence represents a new biologic indicator which is useful for studying the behaviour of living samples in the presence of RF waves due to the modern communication systems. A suitable transmission line, used as an irradiating cell and tested up to the maximum frequency used by the global system for mobile communications and universal mobile telecommunications system transmissions, was characterized. In this experiment, the RF voltage applied to the transmission line was 1 V. Due to short dimensions of the line and the applied high frequencies, standing waves were produced in addition to progressing waves and the electric field strength varies particularly along the longitudinal direction. The magnetic field map was not strongly linked to the electric one due to the presence of standing waves and of the outgoing irradiation. RF fields were measured by two homemade suitable probes able to diagnostic fields of high frequency. The field measurements were performed without any specimens inside the line. Being our sample made of living matter, the real field was modified and its value was estimated by a simulation code. The bioluminescence experiments were performed only at 900 MHz for two different measured electric fields, 53 and 140 V/m. The light emission was measured right from the beginning and after 7 and 25 h. Under RF irradiation, we found that the bioluminescence activity decreased. Compared with the control sample, the diminution was 6.8% and 44% after 7 and 25 h of irradiation, respectively, both with the low or high field. No changes of the survival factor for all the samples were observed. Besides, to understand the emission processes, we operated the deconvolution of the spectra by two Gaussian curves. The Gaussian

  1. Long-term effects of 60-Hz electric vs. magnetic fields on IL-1 and other immune parameters in sheep: Phase 5 study. Final report

    SciTech Connect

    Hefeneider, S.H.; McCoy, S.L.; Hausman, F.A.

    1998-10-01

    This study was designed to assess the effect of exposure to long-term low-frequency electric and magnetic fields (EMF) from a 500-kV transmission line on immune function in sheep. The primary hypothesis was that the reduction in IL-1 activity observed in two previous short-term studies (9 months) was due to EMF exposure from this transmission line. The secondary hypothesis was that long-term exposure (27 months) would impact immune function and animal health. To characterize the components of EMF responsible for the previously observed reduction in IL-1 activity, the experiment was designed not only to examine the effect of exposure to electric and magnetic fields, but also to examine the magnetic field component alone.

  2. Long-term effects of 60-Hz electric vs. magnetic fields on IL-1 and other immune parameters in sheep: Phase 4 study. Final report

    SciTech Connect

    Hefeneider, S.H.; McCoy, S.L.; Hausman, F.A.

    1998-10-01

    This study was designed to assess the effect of exposure to long-term low-frequency electric and magnetic fields (EMF) from an environmental 500-kV transmission line on immune function in sheep. The primary hypothesis tested was that the reduction in IL-1 activity observed in two previous short-term studies (9 months) was due to exposure to EMF from this transmission line. The secondary hypothesis was that long-term exposure (27 months) would impact immune function and animal health. To characterize the components of the EMF environment responsible for the previously observed reduction in IL-1 activity, the experiment was designed not only to examine the effect of exposure to electric and magnetic fields, but also to examine the magnetic field component alone. This was done by constructing a third pen (MF) which was shielded with wire to effectively eliminate the electric field while not significantly affecting the magnitude of the magnetic field.

  3. View facing north (30°) of Transmission Line entering Teton River ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View facing north (30°) of Transmission Line entering Teton River Valley, near Structure 40-7 - Havre Rainbow Transmission Line, Havre City to Great Falls vicinity, Montana, Great Falls, Cascade County, MT

  4. View facing south (210°) of Transmission Line going over hill, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View facing south (210°) of Transmission Line going over hill, Structure 46-12 in foreground, near Collins School - Havre Rainbow Transmission Line, Havre City to Great Falls vicinity, Montana, Great Falls, Cascade County, MT

  5. View facing northeast (60°) of Structure 259, other transmission lines ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View facing northeast (60°) of Structure 25-9, other transmission lines and small farmstead visible in background - Havre Rainbow Transmission Line, Havre City to Great Falls vicinity, Montana, Great Falls, Cascade County, MT

  6. Analysis of the ITER LFS Reflectometer Transmission Line System

    SciTech Connect

    Hanson, Gregory R; Wilgen, John B; Bigelow, Tim S; Diem, Stephanie J; Biewer, Theodore M

    2010-01-01

    A critical issue in the design of the ITER Low Field Side (LFS) reflectometer is the transmission line (TL) system. A TL connects each launcher to a diagnostic instrument. Each TL will typically consist of ~42 m of corrugated waveguide and up to 10 miter bends. Important issues for the performance of the TL system are mode conversion and reflections. Minimizing mode conversion and reflections in the waveguide are critical to minimizing standing waves and phase errors in the reflectometer-measured phase. The performance of the corrugated waveguide and miter bends is analyzed and recommendations given.

  7. Field quality measurements of a 2-Tesla transmission line magnet

    SciTech Connect

    Velev, G.V.; Foster, W.; Kashikhin, V.; Mazur, P.; Oleck, A.; Piekarz, H.; Schlabach, P.; Sylvester, C.; Wake, M.; /KEK, Tsukuba

    2005-09-01

    A prototype 2-Tesla superconducting transmission line magnet for future hadron colliders was designed, built and tested at Fermilab. The 1.5 m long, combined-function gradient-dipole magnet has a vertical pole aperture of 20 mm. To measure the magnetic field quality in such a small magnet aperture, a specialized rotating coil of 15.2 mm diameter, 0.69 m long was fabricated. Using this probe, a program of magnetic field quality measurements was successfully performed. Results of the measurements are presented and discussed.

  8. Modeling of planar quasi-TEM superconducting transmission lines

    NASA Technical Reports Server (NTRS)

    Antsos, Dimitrios; Chew, Wilbert; Riley, A. L.; Hunt, Brian D.; Foote, Marc C.; Bajuk, Louis J.; Rascoe, Daniel L.; Cooley, Thomas W.

    1992-01-01

    An application of the phenomenological loss equivalence method (Lee and Itoh, 1989) in modeling the microwave behavior of planar quasi-TEM superconducting transmission lines is presented. For validation of the model, data are used from measurements of a YBCO superconducting thin-film coplanar-waveguide lowpass filter on a lanthanum aluminate substrate. Measured and modeled S-parameters of an existing superconducting coplanar waveguide lowpass filter agree to within 0.3 dB in magnitude and 0.5 radians in phase. Extracted values for penetration depth and real part of the conductivity of the superconducting film are within 10 percent of other researchers' findings.

  9. A Poynting vector transducer for transmission line monitoring and protection

    SciTech Connect

    Fam, W.Z. )

    1994-01-01

    A new type of transducer is described which enables the continuous monitoring of transmission line current voltage, real and reactive power, and which can also be used to operate the relays necessary for the protection of the line. The new transducer is designed as an integrated unit containing both the current and voltage sensors, thus eliminating the need for conventional current transformers and voltage transformers. The signals from the two sensors are processed using a simple electronic circuit which brings them to a level suitable for metering and relaying purposes. An analogue to digital interface enables the transducer to be connected to a computer for continuous data acquisition storage and monitoring. Due to its geometry and its simple structure, the transducer is ideally suitable for integration into a gas-insulated busbar duct system.

  10. Dispersion in Nb microstrip transmission lines at submillimeter wave frequencies

    NASA Technical Reports Server (NTRS)

    Javadi, H. H. S.; Mcgrath, W. R.; Bumble, B.; Leduc, H. G.

    1992-01-01

    We have measured the effects of dispersion on the resonant mode frequencies of open-ended Nb-SiO(x)-Nb microstrip transmission lines over a frequency range from 50 to 800 GHz. Submicron Nb/Al-AlOx/Nb Josephson junctions were used as both voltage-controlled oscillators and detectors to sample the high order modes of the resonators. The resonator modes are equally spaced up to about 550 GHz where the mode spacing start to decrease gradually to a minimum above the gap frequency of about 700 GHz and then increases. Results are in good agreement with the expected theoretical behavior based on the Mattis-Bardeen conductivity of the superconductor line.

  11. LineCast: line-based distributed coding and transmission for broadcasting satellite images.

    PubMed

    Wu, Feng; Peng, Xiulian; Xu, Jizheng

    2014-03-01

    In this paper, we propose a novel coding and transmission scheme, called LineCast, for broadcasting satellite images to a large number of receivers. The proposed LineCast matches perfectly with the line scanning cameras that are widely adopted in orbit satellites to capture high-resolution images. On the sender side, each captured line is immediately compressed by a transform-domain scalar modulo quantization. Without syndrome coding, the transmission power is directly allocated to quantized coefficients by scaling the coefficients according to their distributions. Finally, the scaled coefficients are transmitted over a dense constellation. This line-based distributed scheme features low delay, low memory cost, and low complexity. On the receiver side, our proposed line-based prediction is used to generate side information from previously decoded lines, which fully utilizes the correlation among lines. The quantized coefficients are decoded by the linear least square estimator from the received data. The image line is then reconstructed by the scalar modulo dequantization using the generated side information. Since there is neither syndrome coding nor channel coding, the proposed LineCast can make a large number of receivers reach the qualities matching their channel conditions. Our theoretical analysis shows that the proposed LineCast can achieve Shannon's optimum performance by using a high-dimensional modulo-lattice quantization. Experiments on satellite images demonstrate that it achieves up to 1.9-dB gain over the state-of-the-art 2D broadcasting scheme and a gain of more than 5 dB over JPEG 2000 with forward error correction. PMID:24474371

  12. Extragalactic Jets as Electrical Circuits and Transmission Lines

    NASA Astrophysics Data System (ADS)

    Kronberg, Philipp

    2014-10-01

    I describe the first attempt to measure a current in an extended radio galaxy jet: ~1018A at ~50 kpc from the elliptical galaxy's ultra-compact nucleus. This class of jet is known to transport its magnetic energy ``intact'', up to supragalactic scales. I discuss plasma parameters for 3C303 and recent attempts to measure its jet axial current. I discuss analogies with both electrical circuits, - and transmission lines. Power is delivered into a ``load'', whose impedance, Z, is close to that of free space, and the jet power flow I2 Z is ~1035 erg s-1 - broadly consistent with astronomically measured total power outputs, luminosities and lifetimes of AGN-powered radio lobes.The current and power levels are also consistent with SMBH accretion disk model predictions by Stirling Colgate, H. Li, V. Pariev, J. Finn, and others, beginning with Lovelace 1976 (Nature). A further analogy with transmission lines shows how the supragalactic power flows can be disrupted by a complex impedance in the ``circuit.'' Reactive components in space, i.e. a complex Z, can disrupt, reflect or deflect the power flow. This could explain the wide variety of magneto-plasma configurations seen in these systems. Funded by NSERC Discovery Grant A5713.

  13. Recyclable Transmission Line (RTL) Concept for Z-Pinch IFE*

    NASA Astrophysics Data System (ADS)

    Olson, C. L.; Slutz, S. A.; Rochau, G. E.; Morrow, C. W.; Kammer, D. C.; Fatenejad, M.; El-Guebaly, L. A.; de Groot, J. S.; Peterson, P. F.

    2003-10-01

    The Recyclable Transmission Line (RTL) concept for IFE uses a recyclable material for the magnetically-insulated transmission line that connects the pulsed power accelerator to the z-pinch fusion target. The RTL may be made of frozen coolant (e.g., Flibe) or a material that is easily separable from the coolant (e.g., low activation ferritic steel). Initial experiments on Saturn at the 10 MA level have already shown excellent electrical turn-on for several candidate RTL materials, and demonstrated high electrical conductivities for thin low-mass RTLs. The present RTL baseline is a 50 kg ferritic steel RTL operating in a 10-20 Torr background chamber pressure. Initial results of investigations are presented on the RTL structural strength (buckling analysis); post-shot RTL formation of schrapnel/plasma; vacuum and electrical RTL connections to the power feed; post-shot effects up the RTL (EMP, schrapnel, etc.); activation and waste stream analysis; study of mechanical properties of foam Flibe; handling of sheer mass of RTLs (one-day storage supply, etc.); and RTL manufacturing and recycling system design.

  14. Investigation of effects of 60-Hz electric and magnetic fields on operant and social behavior and on the neuroendocrine system of nonhuman primates

    SciTech Connect

    Smith, H.D.

    1992-11-02

    The objective of this program is to investigate behavioral and neuroendocrine effects associated with exposure to 60-Hz electric and magnetic fields (E/MF), using the baboon surrogate for the human. Baboon social groups were scanned and electronically monitored during Experiments IV and IVA. The social scan, form that the technicians used to identify baboon locations and proximity to other baboons: was used to gain a simple snapshot of the position of the baboons in their cage. The scans were taken hourly every morning and evening for a total of eight scans per side per day. This report covers in detail the scan and activity data-gathering process. A set of appendices is attached which include printouts of the data sets and adjunct material pertinent to interpreting the data. The supporting material is comprised of calendars and listings of major events that occurred during the scan and activity data collection.

  15. Investigation of effects of 60-Hz electric and magnetic fields on operant and social behavior and on the neuroendocrine system of nonhuman primates

    SciTech Connect

    Rhodes, J.W.

    1992-07-14

    This volume contains detailed experimental data to accompany quarterly report, dated July 14, 1992, by this group entitled Investigation of Effects of 60-Hz Electric Fields on Operant and Social Behavior and on the Neuroendocrine System of Nonhuman Primates.'' This volume is a collection of Appendices which are entitled: Appendix A- Field Mapping Data Forms, Appendix B- Exposure Area (East Side) Electric Field Data, Appendix C- Exposure Area (East Side) Magnetic Field Data, Appendix D- Sham Area (West Side) Magnetic Field Data, Appendix E- Memoranda Concerning Field Onset During Experiment IV and the Crossover Experiment, Appendix F- Exposure Area (East Side) Electric Field Data, Appendix G- Exposure Area (East Side) Magnetic Field Data, Appendix H- Sham Area (west Side) Magnetic Field Data, Appendix I- Compiled Data and Anovas for Experiment III Social Data, Appendix J -Written Comments Provided by Statistician Dr. Robert Mason, and Appendix K- Reference Text Provided by Dr. Coelho.

  16. Very Broadband Rayleigh-Wave Dispersion (0.06 - 60 Hz) and Shear-Wave Velocity Structure Under Yucca Flat, Nevada Test Site

    NASA Astrophysics Data System (ADS)

    Schramm, K. A.; Bilek, S. L.; Patton, H. J.; Abbott, R. E.; Stead, R.; Pancha, A.; White, R.

    2009-12-01

    Earth structure plays an important role in the generation of seismic waves for all sources. Nowhere is this more evident than at near-surface depths where man-made sources, such as explosions, are conducted. For example, short-period Rayleigh waves (Rg) are excited and propagate in the upper 2 km of Earth's crust. The importance of Rg in the generation of S waves from explosion sources through near-source scattering depends greatly on the shear-wave velocity structure at very shallow depths. Using three distinct datasets, we present a very broadband Rayleigh-wave phase velocity dispersion curve for the Yucca Flat (YF) region of the Nevada Test Site (NTS). The first dataset consists of waveforms of historic NTS explosions recorded on regional seismic networks and will provide information for the lowest frequencies (0.06-0.3 Hz). The second dataset is comprised of waveforms from a non-nuclear explosion on YF recorded at near-local distances and will be used for mid-range frequencies (0.2-1.5 Hz). The third dataset contains high-frequency waveforms recorded from refraction microtremor surveys on YF. This dataset provides information between 1.5 and 60 Hz. Initial results from the high frequency dataset indicate velocities range from 0.45-0.9 km/s at 1.5 Hz and 0.25-0.45 km/s at 60 Hz. The broadband nature of the dispersion curve will allow us to invert for the shear-wave velocity structure to 10 km depth, with focus on shallow depths where nuclear tests were conducted in the YF region. The velocity model will be used by researchers as a tool to aid the development of new explosion source models that incorporate shear wave generation. The new model can also be used to help improve regional distance yield estimation and source discrimination for small events.

  17. Doppler-shifted neutral beam line shape and beam transmission

    SciTech Connect

    Kamperschroer, J.H.; Grisham, L.R.; Kokatnur, N.; Lagin, L.J.; Newman, R.A.; O`Connor, T.E.; Stevenson, T.N.; von Halle, A.

    1994-04-01

    Analysis of Doppler-shifted Balmer-{alpha} line emission from the TFTR neutral beam injection systems has revealed that the line shape is well approximated by the sum of two Gaussians, or, alternatively, by a Lorentzian. For the sum of two Gaussians, the broad portion of the distribution contains 40% of the beam power and has a divergence five times that of the narrow part. Assuming a narrow 1/e- divergence of 1.3{degrees} (based on fits to the beam shape on the calorimeter), the broad part has a divergence of 6.9{degrees}. The entire line shape is also well approximated by a Lorentzian with a half-maximum divergence of 0.9{degrees}. Up to now, fusion neutral beam modelers have assumed a single Gaussian velocity distribution, at the extraction plane, in each direction perpendicular to beam propagation. This predicts a beam transmission efficiency from the ion source to the calorimeter of 97%. Waterflow calorimetry data, however, yield a transmission efficiency of {approximately}75%, a value in rough agreement with predictions of the Gaussian or Lorentzian models presented here. The broad wing of the two Gaussian distribution also accurately predicts the loss in the neutralizer. An average angle of incidence for beam loss at the exit of the neutralizer is 2.2{degrees}, rather than the 4.95{degrees} subtended by the center of the ion source. This average angle of incidence, which is used in computing power densities on collimators, is shown to be a function of beam divergence.

  18. Smaller-loss planar SPP transmission line than conventional microstrip in microwave frequencies

    PubMed Central

    Zhang, Hao Chi; Zhang, Qian; Liu, Jun Feng; Tang, Wenxuan; Fan, Yifeng; Cui, Tie Jun

    2016-01-01

    Transmission line is a basic component in all passive devices, integrated circuits, and systems. Microstrip is the most popular transmission line in the microwave and millimeter-wave frequencies, and has been widely used in current electronic devices, circuits, and systems. One of the important issues to be solved in such applications is the relatively large transmission loss of microstrip. Here, we propose a method to reduce the loss of microwave transmission line based on the designable wavenumber of spoof surface plasmon polaritons (SPPs). Using this characteristic, we analyze and experimentally demonstrate the low-loss feature of the SPP transmission line through the perturbation method and S-parameter measurements, respectively. Both simulation and experimental results show that the SPP transmission line has much smaller transmission loss than traditional microstrip with the same size in the microwave frequencies. Hence, the spoof SPP transmission line may make a big step forward in the low-loss circuits and systems. PMID:26983911

  19. Smaller-loss planar SPP transmission line than conventional microstrip in microwave frequencies.

    PubMed

    Zhang, Hao Chi; Zhang, Qian; Liu, Jun Feng; Tang, Wenxuan; Fan, Yifeng; Cui, Tie Jun

    2016-01-01

    Transmission line is a basic component in all passive devices, integrated circuits, and systems. Microstrip is the most popular transmission line in the microwave and millimeter-wave frequencies, and has been widely used in current electronic devices, circuits, and systems. One of the important issues to be solved in such applications is the relatively large transmission loss of microstrip. Here, we propose a method to reduce the loss of microwave transmission line based on the designable wavenumber of spoof surface plasmon polaritons (SPPs). Using this characteristic, we analyze and experimentally demonstrate the low-loss feature of the SPP transmission line through the perturbation method and S-parameter measurements, respectively. Both simulation and experimental results show that the SPP transmission line has much smaller transmission loss than traditional microstrip with the same size in the microwave frequencies. Hence, the spoof SPP transmission line may make a big step forward in the low-loss circuits and systems. PMID:26983911

  20. Investigation of effects of 60-Hz electric and magnetic fields on operant and social behavior and on the neuroendocrine system of nonhuman primates. Quarterly report 37 - Part 1, Text

    SciTech Connect

    Rhodes, J.W.

    1992-07-14

    The objective of this program is to investigate behavioral and neuroendocrine effects associated with exposure to 60-Hz electric and magnetic fields, using the baboon (Papio cynocephalus). Results from this program are used to estimate consequences of human exposure to the electric and magnetic fields associated with electric power transmission. Electric and magnetic field measurements for Experiment IIIA (Confirmatory), Experiment IV and Social Behavior portion of Experiment III are presented. The systems for the production and monitoring of the fields performed satisfactorily during Experiment IIIA and during all but the last part of Experiment IV. In Experiment III, two-way repeated analyses of variance revealed statistically significant Group (Exposed and Sham Exposed) and Period (Baseline. Exposure, and Post-Exposure) main effects. Two significant Period by Group interactions were also found. Seven of the ten behavioral categories showed a main effect of Period. Two-sample t-test comparisons of the two groups for each period indicated that performance rates in two behavioral categories (Stereotypy and Posture) were significantly lower in the Exposure Group. In general, the Exposed subjects exhibited a trend of progressively lower performance rates across the three periods. Specific accomplishments reported in this document were: measurement of electric and magnetic fields for Experiments IIIA and IV, completed analysis of the Social Behavioral data from Experiment III, and a detailed discussion of statistical methods employed on the Social Behavioral portion of Experiment III, and hematology data were collected and recorded for Operant and Social Behavioral subjects for Experiment IV.

  1. Wild Horse 69-kV transmission line environmental assessment

    SciTech Connect

    1996-12-01

    Hill County Electric Cooperative Inc. (Hill County) proposes to construct and operate a 69-kV transmission line from its North Gildford Substation in Montana north to the Canadian border. A vicinity project area map is enclosed as a figure. TransCanada Power Corporation (TCP), a Canadian power-marketing company, will own and construct the connecting 69-kV line from the international border to Express Pipeline`s pump station at Wild Horse, Alberta. This Environmental Assessment is prepared for the Department of Energy (DOE) as lead federal agency to comply with the requirements of the National Environmental Policy Act (NEPA), as part of DOE`s review and approval process of the applications filed by Hill County for a DOE Presidential Permit and License to Export Electricity to a foreign country. The purpose of the proposed line is to supply electric energy to a crude oil pump station in Canada, owned by Express Pipeline Ltd. (Express). The pipeline would transport Canadian-produced oil from Hardisty, Alberta, Canada, to Caster, Wyoming. The Express Pipeline is scheduled to be constructed in 1996--97 and will supply crude oil to refineries in Wyoming and the midwest.

  2. A study of electric power transmission lines for use on the lunar surface

    SciTech Connect

    Gordon, L.B.; Gaustad, K.L. )

    1991-01-10

    Analytical models have been developed to study the operating characteristics of electrical transmission lines for use on the lunar surface. Important design considerations for a transmission line operating on the lunar surface are mass, temperature, and efficiency. Transmission line parameters which impact these considerations include voltage, power loss, and waveform. The electrical and thermal models developed are used to calculate transmission line mass, size, and temperature as a function of voltage, geometry, waveform, location, and efficiency. The analyses include AC and DC for above and below ground operation. Geometries studied include a vacuum-insulated, two-wire transmission line and a solid-dielectric insulated, coaxial transmission line. A brief discussion of design considerations and the models developed is followed by results for parameter studies for both DC and AC transmission lines.

  3. Material selection of a ferrimagnetic loaded coaxial delay line for phasing gyromagnetic nonlinear transmission lines

    NASA Astrophysics Data System (ADS)

    Johnson, J. M.; Reale, D. V.; Cravey, W. H.; Garcia, R. S.; Barnett, D. H.; Neuber, A. A.; Dickens, J. C.; Mankowski, J. J.

    2015-08-01

    Implementing nonlinear transmission line (NLTL) technology in the design of a high power microwave source has the benefits of producing a comparatively small and lightweight solid-state system where the emission frequency is easily tuned. Usually, smaller in physical size, single NLTLs may produce significantly less power than its vacuum based counterparts. However, combining individual NLTL outputs electrically or in free-space is an attractive solution to achieve greater output power. This paper discusses a method for aligning a four element NLTL antenna array with coaxial geometry using easily adjustable temporal delay lines. These delay lines, sometimes referred to as pulse shock lines or pulse sharpening lines, are placed serially in front of the main NLTL line. The propagation velocity in each delay line is set by the voltage amplitude of an incident pulse as well as the magnetic field bias. Each is adjustable although for the system described in this paper, the voltage is held constant while the bias is changed through applying an external DC magnetic field of varying magnitude. Three different ferrimagnetic materials are placed in the temporal delay line to evaluate which yields the greatest range of electrical delay with the least amount of variability from consecutive shots.

  4. Material selection of a ferrimagnetic loaded coaxial delay line for phasing gyromagnetic nonlinear transmission lines.

    PubMed

    Johnson, J M; Reale, D V; Cravey, W H; Garcia, R S; Barnett, D H; Neuber, A A; Dickens, J C; Mankowski, J J

    2015-08-01

    Implementing nonlinear transmission line (NLTL) technology in the design of a high power microwave source has the benefits of producing a comparatively small and lightweight solid-state system where the emission frequency is easily tuned. Usually, smaller in physical size, single NLTLs may produce significantly less power than its vacuum based counterparts. However, combining individual NLTL outputs electrically or in free-space is an attractive solution to achieve greater output power. This paper discusses a method for aligning a four element NLTL antenna array with coaxial geometry using easily adjustable temporal delay lines. These delay lines, sometimes referred to as pulse shock lines or pulse sharpening lines, are placed serially in front of the main NLTL line. The propagation velocity in each delay line is set by the voltage amplitude of an incident pulse as well as the magnetic field bias. Each is adjustable although for the system described in this paper, the voltage is held constant while the bias is changed through applying an external DC magnetic field of varying magnitude. Three different ferrimagnetic materials are placed in the temporal delay line to evaluate which yields the greatest range of electrical delay with the least amount of variability from consecutive shots. PMID:26329216

  5. Fuzzy logic based on-line fault detection and classification in transmission line.

    PubMed

    Adhikari, Shuma; Sinha, Nidul; Dorendrajit, Thingam

    2016-01-01

    This study presents fuzzy logic based online fault detection and classification of transmission line using Programmable Automation and Control technology based National Instrument Compact Reconfigurable i/o (CRIO) devices. The LabVIEW software combined with CRIO can perform real time data acquisition of transmission line. When fault occurs in the system current waveforms are distorted due to transients and their pattern changes according to the type of fault in the system. The three phase alternating current, zero sequence and positive sequence current data generated by LabVIEW through CRIO-9067 are processed directly for relaying. The result shows that proposed technique is capable of right tripping action and classification of type of fault at high speed therefore can be employed in practical application. PMID:27398278

  6. A computer code to calculate line by line atmospheric transmission spectra on a microcomputer

    NASA Astrophysics Data System (ADS)

    Safren, H. G.

    1987-07-01

    A computer program is described which calculates line by line atmospheric transmission spectra on a microcomputer. Radiance calculations are not included. The program is written in FORTRAN and could be modified to run on a microcomputer other than the one on which it was implemented, except that the plotting routine would have to be replaced. The program is based on the 1978 Air Force Geophysics Laboratory LASER routine, and uses absorption line data from the 1982 update of the AFGL Atmospheric Absorption Line Parameters Compilation; segments of needed line data are taken from the tape, preprocessed into the form used by the program and stored on floppy disks. The program calculates transmission spectra over a variety of paths and spanning an arbitrarily chosen wavelength or frequency range; the path may be chosen to be horizontal, vertical or slanted at any zenith angle, and may extend between any two altitudes between 0 and 15 km. Aerosol effects are included, presently based on the 1976 Shettle and Fenn models, plus some molecular continuum effects and Rayleigh scattering.

  7. Acoustic solitons in waveguides with Helmholtz resonators: transmission line approach.

    PubMed

    Achilleos, V; Richoux, O; Theocharis, G; Frantzeskakis, D J

    2015-02-01

    We report experimental results and study theoretically soliton formation and propagation in an air-filled acoustic waveguide side loaded with Helmholtz resonators. We propose a theoretical modeling of the system, which relies on a transmission-line approach, leading to a nonlinear dynamical lattice model. The latter allows for an analytical description of the various soliton solutions for the pressure, which are found by means of dynamical systems and multiscale expansion techniques. These solutions include Boussinesq-like and Korteweg-de Vries pulse-shaped solitons that are observed in the experiment, as well as nonlinear Schrödinger envelope solitons, that are predicted theoretically. The analytical predictions are in excellent agreement with direct numerical simulations and in qualitative agreement with the experimental observations. PMID:25768623

  8. Gas insulated transmission line having low inductance intercalated sheath

    DOEpatents

    Cookson, Alan H.

    1978-01-01

    A gas insulated transmission line including an outer sheath, an inner conductor disposed within the outer sheath, and an insulating gas between the inner conductor and the outer sheath. The outer sheath comprises an insulating tube having first and second ends, and having interior and exterior surfaces. A first electrically conducting foil is secured to the interior surface of the insulating tube, is spirally wound from one tube end to the second tube end, and has a plurality of overlapping turns. A second electrically conducting foil is secured to the exterior surface of the insulating tube, and is spirally wound in the opposite direction from the first electrically conducting foil. By winding the foils in opposite directions, the inductances within the intercalated sheath will cancel each other out.

  9. Monolithic high voltage nonlinear transmission line fabrication process

    DOEpatents

    Cooper, Gregory A.

    1994-01-01

    A process for fabricating sequential inductors and varactor diodes of a monolithic, high voltage, nonlinear, transmission line in GaAs is disclosed. An epitaxially grown laminate is produced by applying a low doped active n-type GaAs layer to an n-plus type GaAs substrate. A heavily doped p-type GaAs layer is applied to the active n-type layer and a heavily doped n-type GaAs layer is applied to the p-type layer. Ohmic contacts are applied to the heavily doped n-type layer where diodes are desired. Multiple layers are then either etched away or Oxygen ion implanted to isolate individual varactor diodes. An insulator is applied between the diodes and a conductive/inductive layer is thereafter applied on top of the insulator layer to complete the process.

  10. Transmission line corona losses under hoar frost conditions

    SciTech Connect

    Lahti, K.; Nousiainen, K.; Lahtinen, M.

    1997-04-01

    Transmission line corona losses under hoar frost conditions were studied in the climate room of the high voltage laboratory of Tampere University of Technology. The measurements were performed using a coaxial measurement arrangement with different bundle and conductor types. The effects of conductor and bundle type, temperature, applied voltage and hoar frost thickness on corona losses were investigated. A two-conductor bundle had corona losses about 2.5--5 times higher than a three-conductor bundle. Relatively thin hoar frosts were used in the tests. Even the thinnest hoar frost resulted in remarkable corona losses and the losses were very sensitive to changes in the hoar frost thickness. The ambient temperature had a strong influence on the measured losses.

  11. Terahertz Quantum-Cascade Transmission-Line Metamaterials

    NASA Astrophysics Data System (ADS)

    Tavallaee, Amir Ali

    Terahertz quantum-cascade (QC) lasers operating at 0.6 - 5 THz (λ ˜ 60 - 500 µm) are poised to become the dominant solid-state sources of continuous-wave (cw) far-infrared radiation enabling applications in terahertz spectroscopy, imaging, and sensing. QC-lasers are the longest wavelength semiconductor laser sources in which terahertz gain is obtained from electronic intersubband radiative transitions in GaAs/AlGaAs heterostructure quantum wells. Since their invention in 2001, rapid development has enabled demonstration of cw powers greater than 100 mW. However, challenges still remain in the areas of operating temperature, laser efficiency and power, and beam quality to name a few. The highest-temperature operation of terahertz quantum-cascade lasers (200 K pulsed, 117 K cw) depends on the use of a low-loss "metal-metal" waveguide where the active gain material is sandwiched between two metal cladding layers; a technique similar, in concept, to microstrip transmission line technology at microwave frequencies. Due to the subwavelength transverse dimensions of the metal-metal waveguide, however, obtaining a directive beam pattern and efficient out-coupling of THz power is non-trivial. This thesis reports the demonstration of a one-dimensional waveguide for terahertz quantum-cascade lasers that acts as a leaky-wave antenna and tailors laser radiation in one dimension to a directional beam. This scheme adapts microwave transmission-line metamaterial concepts to a planar structure realized in terahertz metal-metal waveguide technology and is fundamentally different from distributed feedback/photonic crystal structures that work based on Bragg scattering of propagating modes. The leaky-wave metamaterial antenna operates based on a propagating mode with an effective phase index smaller than unity such that it radiates in the surface direction via a leaky-wave mechanism. Surface emission (˜ 40° from broadside) with a single directive beam (FWHM ˜ 15°) at 2.74 THz

  12. Monolithic high voltage nonlinear transmission line fabrication process

    DOEpatents

    Cooper, G.A.

    1994-10-04

    A process for fabricating sequential inductors and varistor diodes of a monolithic, high voltage, nonlinear, transmission line in GaAs is disclosed. An epitaxially grown laminate is produced by applying a low doped active n-type GaAs layer to an n-plus type GaAs substrate. A heavily doped p-type GaAs layer is applied to the active n-type layer and a heavily doped n-type GaAs layer is applied to the p-type layer. Ohmic contacts are applied to the heavily doped n-type layer where diodes are desired. Multiple layers are then either etched away or Oxygen ion implanted to isolate individual varistor diodes. An insulator is applied between the diodes and a conductive/inductive layer is thereafter applied on top of the insulator layer to complete the process. 6 figs.

  13. Tailoring of electron flow current in magnetically insulated transmission lines

    NASA Astrophysics Data System (ADS)

    Martin, J. P.; Savage, M. E.; Pointon, T. D.; Gilmore, M. A.

    2009-03-01

    It is desirable to optimize (minimizing both the inductance and electron flow) the magnetically insulated vacuum sections of low impedance pulsed-power drivers. The goal of low inductance is understandable from basic efficiency arguments. The goal of low electron flow results from two observations: (1) flowing electrons generally do not deliver energy to (or even reach) most loads, and thus constitute a loss mechanism; (2) energetic electrons deposited in a small area can cause anode damage and anode plasma formation. Low inductance and low electron flow are competing goals; an optimized system requires a balance of the two. While magnetically insulated systems are generally forgiving, there are times when optimization is crucial. For example, in large pulsed-power drivers used to energize high energy density physics loads, the electron flow as a fraction of total current is small, but that flow often reaches the anode in relatively small regions. If the anode temperature becomes high enough to desorb gas, the resulting plasma initiates a gap closure process that can impact system performance. Magnetic-pressure driven (z pinches and material equation of state) loads behave like a fixed inductor for much of the drive pulse. It is clear that neither fixed gap nor constant-impedance transmission lines are optimal for driving inductive loads. This work shows a technique for developing the optimal impedance profile for the magnetically insulated section of a high-current driver. Particle-in-cell calculations are used to validate the impedance profiles developed in a radial disk magnetically insulated transmission line geometry. The input parameters are the spacing and location of the minimum gap, the effective load inductance, and the desired electron flow profile. The radial electron flow profiles from these simulations are in good agreement with theoretical predictions when driven at relatively high voltage (i.e., V≥2MV).

  14. 49 CFR 192.715 - Transmission lines: Permanent field repair of welds.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Transmission lines: Permanent field repair of... § 192.715 Transmission lines: Permanent field repair of welds. Each weld that is unacceptable under § 192.241(c) must be repaired as follows: (a) If it is feasible to take the segment of transmission...

  15. 49 CFR 192.711 - Transmission lines: General requirements for repair procedures.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Transmission lines: General requirements for... Maintenance § 192.711 Transmission lines: General requirements for repair procedures. (a) Temporary repairs..., imperfection, or damage that impairs its serviceability is found in a segment of steel transmission...

  16. 49 CFR 192.711 - Transmission lines: General requirements for repair procedures.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Transmission lines: General requirements for... Maintenance § 192.711 Transmission lines: General requirements for repair procedures. (a) Temporary repairs..., imperfection, or damage that impairs its serviceability is found in a segment of steel transmission...

  17. 49 CFR 192.715 - Transmission lines: Permanent field repair of welds.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Transmission lines: Permanent field repair of... § 192.715 Transmission lines: Permanent field repair of welds. Each weld that is unacceptable under § 192.241(c) must be repaired as follows: (a) If it is feasible to take the segment of transmission...

  18. Polar On-Line Acquisition Relay and Transmission System (POLARATS)

    SciTech Connect

    Yuracko, K.

    2004-07-15

    POLARATS (Polar On-Line Acquisition Relay And Transmission System) is being developed by YAHSGS LLC (YAHSGS) and Oak Ridge National Laboratory (ORNL) to provide remote, unattended monitoring of environmental parameters under harsh environmental conditions. In particular, instrumental design and engineering is oriented towards protection of human health in the Arctic, and with the additional goal of advancing Arctic education and research. POLARATS will obtain and transmit environmental data from hardened monitoring devices deployed in locations important to understanding atmospheric and aquatic pollutant migration as it is biomagnified in Arctic food chains. An Internet- and personal computer (PC)-based educational module will provide real time sensor data, on-line educational content, and will be integrated with workbooks and textbooks for use in middle and high school science programs. The educational elements of POLARATS include an Internet-based educational module that will instruct students in the use of the data and how those data fit into changing Arctic environments and food chains. POLARATS will: (1) Enable students, members of the community, and scientific researchers to monitor local environmental conditions in real time over the Internet; and (2) Provide additional educational benefits through integration with middle- and high-school science curricula. Information will be relayed from POLARATS devices to classrooms and libraries along with custom-designed POLARATS teaching materials that will be integrated into existing curricula to enhance the educational benefits realized from the information obtained.

  19. LOSS ESTIMATE FOR ITER ECH TRANSMISSION LINE INCLUDING MULTIMODE PROPAGATION

    SciTech Connect

    Shapiro, Michael; Bigelow, Tim S; Caughman, John B; Rasmussen, David A

    2010-01-01

    The ITER electron cyclotron heating (ECH) transmission lines (TLs) are 63.5-mm-diam corrugated waveguides that will each carry 1 MW of power at 170 GHz. The TL is defined here as the corrugated wave guide system connecting the gyrotron mirror optics unit (MO U) to the entrance of the ECH launcher and includes miter bends and other corrugated wave guide components. The losses on the ITER TL have been calculated for four possible cases corresponding to having HE(11) mode purity at the input of the TL of 100, 97, 90, and 80%. The losses due to coupling, ohmic, and mode conversion loss are evaluated in detail using a numerical code and analytical approaches. Estimates of the calorimetric loss on the line show that the output power is reduced by about 5, +/- 1% because of ohmic loss in each of the four cases. Estimates of the mode conversion loss show that the fraction of output power in the HE(11) mode is similar to 3% smaller than the fraction of input power in the HE(11) mode. High output mode purity therefore can be achieved only with significantly higher input mode purity. Combining both ohmic and mode conversion loss, the efficiency of the TL from the gyrotron MOU to the ECH launcher can be roughly estimated in theory as 92% times the fraction of input power in the HE(11) mode.

  20. The effect of 60-Hz magnetic fields on co-promotion of chemically induced skin tumors on SENCAR mice: a discussion of three studies.

    PubMed Central

    McLean, J R; Thansandote, A; Lecuyer, D; Goddard, M

    1997-01-01

    Three independent experiments involving a total of 288 SENCAR mice were used to study the effects of 60-Hz magnetic fields on the growth and development of skin tumors. Given the constraints imposed by the experimental design, the results did not support a role for magnetic fields as a tumor co-promoter. This negative finding could also be interpreted to mean that the SENCAR mouse skin tumor model was not sensitive enough to detect the action of a weak co-promoter. The two-stage (initiation/promotion) model was used to assess the genotoxic potential of magnetic fields because it had been widely used to evaluate chemical carcinogens. This model, however, lacks the sensitivity to detect all but the most potent direct-acting carcinogens, and the tumor response to the action of low doses of promoter results in large random fluctuations in tumor incidence, yield, and multiplicity. The need to limit tumor incidence in the sham is a necessary condition to ensure that a magnetic field-induced effect on tumorigenesis would have a reasonable chance of being detected. This requirement, and the variability in tumor development between and within experiments, increases the level of uncertainty in the system and makes a weak response to the magnetic field difficult to detect and interpret. PMID:9074887

  1. Chronically indwelling venous cannula and automatic blood sampling system for use with nonhuman primates exposed to 60 Hz electric and magnetic fields

    SciTech Connect

    Rogers, W.R.; Lucas, J.H.; Smith, H.D.; Orr, J.L.; Mikiten, B.C.

    1995-12-31

    An automated blood sampling system was developed for use with tethered baboons (Papio cynocephalus) during concurrent exposure to 60 Hz 30 kV/m electric fields and 0.1 mT (1.0 G) magnetic fields. The system was controlled by a FORTH-based microcomputer, which operated a pump, a fraction collector, and two pinch valves. A swivel mechanism at the end of the tether allowed the baboons to move freely in their cages. The hardware and software were designed for fail-safe operation. Heparinized saline was infused at a rate of 0.5 ml/min until a sample cycle was initiated. Then, blood was drawn from the animal into a storage tube at a rate of 12.5 ml/min, a sample of undiluted blood was taken from the end of the storage tube near the baboon, and the blood remaining in the storage tube was then flushed back into the animal. Use of the storage tube prevented the peristaltic pump rollers from pressing on tubing containing blood, and return of the blood diluted with saline limited the blood wasted per sample to less than 0.5 ml. The system functioned reliably in three experiments, collecting samples as scheduled 97% of the time. Although it was initially designed for and used successfully with primates in an electric and magnetic field environment, this type of system could be employed in many areas of biomedical research or medical treatment.

  2. Initial studies on the effects of combined 60 Hz electric and magnetic field exposure on the immune system of nonhuman primates

    SciTech Connect

    Murthy, K.K.; Rogers, W.R.; Smith, H.D.

    1995-12-31

    In a pilot immunology experiment, peripheral blood samples from six baboons (Papio cynocephalus) housed as a social group were collected during week 5 of preexposure, exposure, and postexposure periods that were each 6 weeks in duration. The subjects were exposed to vertical 6 kV/m and horizontal 50 {micro}T (0.5 G) fields for 12 h per day. Lymphocytes collected during the exposure period displayed statistically significant (P < .05) reductions in CD3{sup +} and CD4{sup +} counts, interleukin 2 receptor expression, and proliferative response to pokeweed mitogen. A second experiment was conducted using samples from seven subjects exposed to 30 kV/m and 100 {micro}T (1.0 G) and eight sham-exposed subjects. Statistically significant Period {times} Group interactions occurred for total white blood cell count and CD4{sup +} to CD8{sup +} ratio, but the pattern of results was not suggestive of an exposure-related effect. Although components of the nonhuman primate immune system appear to be affected by 60 Hz electric and magnetic field exposure in one of two experiments, additional experiments are required to evaluate this possibility.

  3. Evaluation of the possible copromoting effect of a 60 Hz magnetic field during chemically induced carcinogenesis in skin of SENCAR mice. Final report

    SciTech Connect

    DiGiovanni, J.; Walborg, E.F.; Anderson, L.E.; Sasser, L.B.; Morris, J.E.; Miller, D.L. |

    1997-11-01

    It has been hypothesized that exposure to extremely low frequency (ELF) magnetic fields can enhance tumorigenesis through a copromotional mechanism. Equivocal support for this hypothesis was provided by experiments performed by Stuchly et al. using a mouse skin model; i.e. the induction of skin tumors in SENCAR mice exposed to a single subcarcinogenic dose of 7,12-dimethylbenz(a)anthracene (DMBA) and promotion by repetitive doses of 12-O-tetradecanoylphorbol-13-acetate (TPA). The mice were exposed to a 2 mT (60 Hz) magnetic field during the entire promotion phase of the experiment. The Stuchly study, which utilized single weekly doses of TPA, demonstrated a statistically significant increase in skin tumors after 16--18 weeks of promotion; however, by 23 weeks of promotion, the difference was not statistically significant. The study was designed to provide definitive evidence to confirm or refute a copromotional role of ELF magnetic field exposure on DMBA/TPA-induced skin carcinogenesis in SENCAR mice. This study was modeled after the study of Stuchly et al., (1992), including the animal model and exposure conditions. However, three different promoting doses of TPA, within the linear dose response range for induction of skin tumors, were utilized.

  4. Effects of high-voltage transmission lines on honeybees

    SciTech Connect

    Greenberg, B.; Bindokas, V.P.; Gauger, J.R.

    1985-05-01

    When shielded and exposed colonies were placed at incremental distances at a right angle from a 760-kV transmission line different thresholds for biologic effects were obtained. Hive exposures were controlled (E-field: 7, 5.5, 4.1, 1.8, and 0.65 to 0.85 kV/m) by variable height current collectors; shielded hives under the line behave normally. Exposure to 7 kV/m can produce the following sequence of events: (1) increased motor activity and transient hive temperature increase; (2) abnormal propolization; (3) retarded hive weight gain; (4) excess queen cell production with queen loss; (5) reduction of sealed brood area; and (6) poor winter survival. No biological effects were detected below 4.1 kV/m, thus the ''biological effects corridor'' is limited to approximately 23 m beyond a ground projection of each outer phase wire. Hive architecture enhances E-fields and creates shock hazards for bees. Intra-hive E-fields (15 to 100+ kV/m) were measured with a displacement current sensor and fiber optic telemetry link. Step-potential-induced currents up to 0.5 uA were measured with a bee model in hives at 7 kV/m. To investigate further the role of shock versus electric field exposure the study was continued to develop hive entrance extensions (porches), which produce controlled bee exposure to E-field or shock, and to test the feasibility of using these porches in such a study. Biological effects (e.g., abnormal propolization, retarded hive weight, queen loss) found in colonies with total-hive exposure were produced by entrance-only exposure of adult bees. We now have an exposure system in which E-field and shock can be separately controlled to reproduce the biological effects. 10 refs.

  5. Dielectric loss measurements using an embedded transmission line resonator

    NASA Astrophysics Data System (ADS)

    Sarabi, Bahman; Stoutimore, M. J. A.; Khalil, Moe; Gladchenko, Sergiy; Kozen, Alexander; Rubloff, Gary; Wellstood, F. C.; Lobb, J. C.; Osborn, K. D.

    2011-03-01

    Lossy dielectrics are a major source of decoherence in superconducting qubits. Superconducting linear resonators have proven to be ideally suited for measuring loss in different dielectrics due to their versatility and relative simplicity in design, fabrication, and measurement. We will present data from samples where the low-loss coplanar resonators are fabricated on top of AlOx dielectric films grown using atomic layer deposition (ALD). Although the low-power loss can be extracted from this geometry, embedding the dielectric under study between metal films has advantages that we will discuss. In addition, ALD films can be grown conformally and without pinholes to small thicknesses in comparison to conventional PECVD films. This allows us to make lumped-element resonators with a relatively small footprint, which can easily be embedded within the transmission line. This research was supported by the Intelligence Advanced Research Projects Activity through the U.S. Army Research Office award No. W911NF-09-1-0351.

  6. Requirements for self-magnetically insulated transmission lines

    DOE PAGESBeta

    VanDevender, J. Pace; Pointon, Timothy D.; Seidel, David B.; Struve, Kenneth W.; Jennings, Christopher; Oliver, Bryan V.; Schneider, Larry X.

    2015-03-01

    Self-magnetically insulated transmission lines (MITLs) connect pulsed-power drivers with a load. Although the technology was originally developed in the 1970s and is widely used today in super power generators, failure of the technology is the principal limitation on the power that can be delivered to an experiment. We address issues that are often overlooked, rejected after inadequate simulations, or covered by overly conservative assumptions: (i) electron retrapping in coupling MITLs to loads, (ii) the applicability of collisionless versus collisional electron flow, (iii) power transport efficiency as a function of the geometry at the beginning of the MITL, (iv) gap closuremore » and when gap closure can be neglected, and (v) the role of negative ions in causing anode plasmas and enhancing current losses. We suggest a practical set of conservative design requirements for self-magnetically insulated electron flow based on the results discussed in this paper and on previously published results. The requirements are not necessarily severe constraints in all MITL applications; however, each of the 18 suggested requirements should be examined in the design of a MITL and in the investigation of excessive losses.« less

  7. Ultrastrong coupling in a flux qubit-transmission line system

    NASA Astrophysics Data System (ADS)

    Forn-Diaz, Pol; Orgiazzi, Jean-Luc; Otto, Martin; Yurtalan, Ali; Peropadre, Borja; Garcia-Ripoll, Juan-Jose; Wilson, Christopher; Lupascu, Adrian

    Recent advances in circuit QED have enabled the study of light-matter interactions in new regimes of coupling strength. Experiments based on flux qubits coupled to resonators observed indications of the so-called ultrastrong coupling regime, where the coupling strength is comparable to the qubit energy splitting. We have realized an experiment where a flux qubit is coupled to an open transmission line with an adjustable coupling strength, which can be tuned into the ultrastrong coupling regime. When the coupling strength is low, the qubit behaves like an isolated dipole scatterer, reflecting over 97% of the incident coherent probe. At larger coupling strengths, the qubit linewidth exceeds its energy splitting, indicating that the system operates deeply in the ultrastrong coupling regime. We find that qualitative features of the qubit response evolve with the coupling strength in ways unexpected based on scattering calculations within the rotating-wave approximation. Some features of the evolution can be understood in the broader context of the spin-boson model.

  8. INSTRUMENTATION FOR SURVEYING ACOUSTIC SIGNALS IN NATURAL GAS TRANSMISSION LINES

    SciTech Connect

    John L. Loth; Gary J. Morris; George M. Palmer; Richard Guiler; Deepak Mehra

    2003-09-01

    In the U.S. natural gas is distributed through more than one million miles of high-pressure transmission pipelines. If all leaks and infringements could be detected quickly, it would enhance safety and U.S. energy security. Only low frequency acoustic waves appear to be detectable over distances up to 60 km where pipeline shut-off valves provide access to the inside of the pipeline. This paper describes a Portable Acoustic Monitoring Package (PAMP) developed to record and identify acoustic signals characteristic of: leaks, pump noise, valve and flow metering noise, third party infringement, manual pipeline water and gas blow-off, etc. This PAMP consists of a stainless steel 1/2 inch NPT plumbing tree rated for use on 1000 psi pipelines. Its instrumentation is designed to measure acoustic waves over the entire frequency range from zero to 16,000 Hz by means of four instruments: (1) microphone, (2) 3-inch water full range differential pressure transducer with 0.1% of range sensitivity, (3) a novel 3 inch to 100 inch water range amplifier, using an accumulator with needle valve and (4) a line-pressure transducer. The weight of the PAMP complete with all accessories is 36 pounds. This includes a remote control battery/switch box assembly on a 25-foot extension chord, a laptop data acquisition computer on a field table and a sun shield.

  9. Radial transmission line analysis of multi-layer structures

    SciTech Connect

    Hahn, H.; Hammons, L.

    2011-03-28

    The analysis of multi-layer beam tubes is a standard problem and involves axially propagating waves. This treatment is ill suited to a short multi-layer structure such as the present example of a ferrite covered ceramic break in the beam tube at the ERL photo-cathode electron gun. This paper demonstrates that such structure can better be treated by radial wave propagation. The theoretical method is presented and numerical results are compared with measured network analyser data and Microwave Studio generated simulations. The results confirm the concept of radial transmission lines as a valid analytical method. An Energy Recovery Linac (ERL) is being constructed at this laboratory for the purpose of research towards an envisioned Electron Ion Collider. One of the pertinent topics is damping of Higher Order Modes (HOM). In this ERL, the damping is provided by ferrite absorbers in the beam tube. A modified version thereof, a ceramic break surrounded by ferrite, is planed for the superconducting electron gun. The damper here is located at room temperature just outside of the gun. If used in a cavity chain, the ceramic break is in the vacuum tube at helium temperature whereas the ferrite is moved into the cryostat insulating vacuum allowing higher temperatures. The general properties of the ferrite HOM dampers have been published but are more detailed in this paper.

  10. Precision electron flow measurements in a disk transmission line.

    SciTech Connect

    Clark, Waylon T.; Pelock, Michael D.; Martin, Jeremy Paul; Jackson, Daniel Peter Jr.; Savage, Mark Edward; Stoltzfus, Brian Scott; Mendel, Clifford Will, Jr.; Pointon, Timothy David

    2008-01-01

    An analytic model for electron flow in a system driving a fixed inductive load is described and evaluated with particle in cell simulations. The simple model allows determining the impedance profile for a magnetically insulated transmission line given the minimum gap desired, and the lumped inductance inside the transition to the minimum gap. The model allows specifying the relative electron flow along the power flow direction, including cases where the fractional electron flow decreases in the power flow direction. The electrons are able to return to the cathode because they gain energy from the temporally rising magnetic field. The simulations were done with small cell size to reduce numerical heating. An experiment to compare electron flow to the simulations was done. The measured electron flow is {approx}33% of the value from the simulations. The discrepancy is assumed to be due to a reversed electric field at the cathode because of the inductive load and falling electron drift velocity in the power flow direction. The simulations constrain the cathode electric field to zero, which gives the highest possible electron flow.

  11. Requirements for self-magnetically insulated transmission lines

    SciTech Connect

    VanDevender, J. Pace; Pointon, Timothy D.; Seidel, David B.; Struve, Kenneth W.; Jennings, Christopher; Oliver, Bryan V.; Schneider, Larry X.

    2015-03-01

    Self-magnetically insulated transmission lines (MITLs) connect pulsed-power drivers with a load. Although the technology was originally developed in the 1970s and is widely used today in super power generators, failure of the technology is the principal limitation on the power that can be delivered to an experiment. We address issues that are often overlooked, rejected after inadequate simulations, or covered by overly conservative assumptions: (i) electron retrapping in coupling MITLs to loads, (ii) the applicability of collisionless versus collisional electron flow, (iii) power transport efficiency as a function of the geometry at the beginning of the MITL, (iv) gap closure and when gap closure can be neglected, and (v) the role of negative ions in causing anode plasmas and enhancing current losses. We suggest a practical set of conservative design requirements for self-magnetically insulated electron flow based on the results discussed in this paper and on previously published results. The requirements are not necessarily severe constraints in all MITL applications; however, each of the 18 suggested requirements should be examined in the design of a MITL and in the investigation of excessive losses.

  12. 49 CFR 192.717 - Transmission lines: Permanent field repair of leaks.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... encirclement welded split sleeve of appropriate design, unless the transmission line is joined by mechanical... method that reliable engineering tests and analyses show can permanently restore the serviceability...

  13. THE CHARACTERISTIC IMPEDANCE OF RECTANGULAR TRANSMISSION LINES WITH THIN CENTER CONDUCTOR AND AIR DIELECTRIC

    EPA Science Inventory

    The characteristic impedance of large-scale rectangular strip transmission line facilities used for such purposes as EMI susceptibility testing, biological exposures, etc., is discussed. These lines are characterized by a thin center conductor and an air dielectric. Impedance dat...

  14. ``Multifractals in Transmission of Off-line & On-line E-Voting Systems''

    NASA Astrophysics Data System (ADS)

    Maksoed, Wh-

    An e-voting systems is a voting system in which the election data is recorded, stored & processed primarily as digital information. Those are 2 type of e-voting systems: off-line & on-line systems[Alaguvel & Gnanavel, 2013]. ``Using transfer matrix method & multifractal theory, we studied the transmission properties of 1D generalized Fibonacci structures GF(m.n) in which m & n different intervals are integer according to a substitution rule[Yuannong Zhang, et.al,:Multifractal properties of 1D quasi-period Photonic Crystal''. ``Transmission spectra of 1D fractal multilayer structures are found to exhibit self-similar properties'' says Zhukovsky & Lavrinenko in ``Spectral self-similarity in fractal 1D photonic structures'',Photonics & Nanostructures, 2005 whereas Jacob Trevino, et.al studies `structural properties, photonic density of state & bandedge modes of Vogel spiral arrays of dielectric cylinders in air'. Acknowledgment to HE. Mr. AUGUST PARENGKUAN if accepts 1995-2005 Invoicing & Fulfillments to ``KOMPAS'' cq the Prodi of Physics ITB.

  15. Initial exposure to 30 kV/m or 60 kV/m 60 Hz electric fields produces temporary cessation of operant behavior of nonhuman primates

    SciTech Connect

    Rogers, W.R.; Orr, J.L.; Smith, H.D.

    1995-12-31

    In two separate experiments, the authors examined the effects of a 60 Hz electric field (EF) on performance of an operant schedule consisting of two signaled components: fixed-ratio (FR30) and differential reinforcement of low-rate (DRL20). In each experiment, 12 naive baboons (Papio cynocephalus) were assigned randomly to either an EF-exposed experimental group or a sham-exposed control group. A homogeneous vertical EF of 30 kV/m was used in one experiment; 60 kV/m was used in the other. The experimental design for both experiments included 6 week preexposure, exposure, and postexposure periods. The planned analyses indicated no evidence of statistically significant (P < .05) effects of EF exposure. However, exploratory analyses comparing performance during the last week of preexposure and the first week of exposure revealed statistically significant acute effects (work stoppage): The mean response rates of the EF-exposed groups were greatly reduced on day 1 of exposure but were normal by the end of day 2 of EF exposure. The authors hypothesize that introduction of a highly unusual stimulus, the EF, temporarily interfered with normal operant behavior to produce a primary work stoppage. Supplementary cross-over experiments added at the end of each main experiment indicated that work stoppage occurred again when formerly EF-exposed subjects served as sham-exposed controls, while other subjects received their first EF exposure. Presumably, reoccurrence of other stimuli correlated with initial exposure to the EF became sufficient to subsequently cause secondary work stoppage in the absence of direct EF exposure. The primary and secondary work-stoppage effects were reproducible.

  16. Discovery of a Variable-Frequency, 50--60 HZ Quasi-Periodic Oscillation on the Normal Branch of GX 17+2

    NASA Astrophysics Data System (ADS)

    Wijnands, R. A. D.; van der Klis, M.; Psaltis, D.; Lamb, F. K.; Kuulkers, E.; Dieters, S.; van Paradijs, J.; Lewin, W. H. G.

    1996-09-01

    We report the discovery, with the Rossi X-Ray Timing Explorer, of a 50--60 Hz quasi-periodic oscillation (QPO) in GX 17+2. The QPO is seen when GX 17+2 is on the normal branch in the X-ray color-color diagram. Its frequency initially increases from 59 to 62 Hz as the source moves down the normal branch, but below the middle of the normal branch it decreases to ~50 Hz. Together with this frequency decrease, the QPO peak becomes much broader, from ~4 Hz in the upper part of the normal branch to ~15 Hz in the lower normal branch. The rms amplitude remains approximately constant between 1% and 2% along the entire normal branch. From a comparison of the properties of this QPO with those of QPOs previously observed along the normal branch in other Z sources, we conclude that it is most likely the horizontal-branch QPO (HBO). However, this QPO displays a number of unusual characteristics. The decrease in the QPO frequency along the lower normal branch is not in agreement with the predictions of the beat-frequency model for the HBO unless the mass flux through the inner disk decreases as the source moves down the lower normal branch. We tentatively suggest that the required decrease in the mass flux through the inner disk is caused by an unusually rapid increase in the mass flux in the radial inflow as GX 17+2 moves down the normal branch. Assuming that this explanation is correct, we can derive an upper bound on the dipole component of the star's magnetic field at the magnetic equator of 5 x 109 G for a 1.4 Msolar neutron star with a radius of 106 cm.

  17. 78 FR 60273 - Granby Pumping Plant Switchyard-Windy Gap Substation Transmission Line Rebuild, Grand County...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-01

    ...Western Area Power Administration (Western), a power marketing administration in the U.S. Department of Energy (DOE), owns and operates the 69-kilovolt (kV) Granby Pumping Plant Switchyard-Windy Gap Substation (Project) transmission line in Grand County, Colorado. The transmission line is 13.6 miles long. Western proposes to rebuild the single-circuit line as a double-circuit line, increase......

  18. Analysis of the Transient Response of a Dual-Fed RC Transmission Line

    PubMed Central

    Dorraki, Mohsen; Cambrell, Gregory K.; Abbott, Derek

    2015-01-01

    The transient analysis of a uniform transmission line of finite length is considered in this paper. For the first time this paper provides an analytical expression for the time-domain response of an RC transmission line, which is stimulated by a step function that is fed into both ends of the transmission line. In particular, we find an analytical expression for the step response at the center of the transmission line, in order to determine the worst-case rise time. This is of interest, for example, in large charge-coupled device (CCD) arrays, where long polysilicon lines are dual-fed in order to mitigate degradation in rise time. The analytical expressions for the RC transmission line are supported by computer-simulated lumped RC models. PMID:25679379

  19. Electric Utility Transmission and Distribution Line Engineering Program

    SciTech Connect

    Peter McKenny

    2010-08-31

    Economic development in the United States depends on a reliable and affordable power supply. The nation will need well educated engineers to design a modern, safe, secure, and reliable power grid for our future needs. An anticipated shortage of qualified engineers has caused considerable concern in many professional circles, and various steps are being taken nationwide to alleviate the potential shortage and ensure the North American power system's reliability, and our world-wide economic competitiveness. To help provide a well-educated and trained workforce which can sustain and modernize the nation's power grid, Gonzaga University's School of Engineering and Applied Science has established a five-course (15-credit hour) Certificate Program in Transmission and Distribution (T&D) Engineering. The program has been specifically designed to provide working utility engineering professionals with on-line access to advanced engineering courses which cover modern design practice with an industry-focused theoretical foundation. A total of twelve courses have been developed to-date and students may select any five in their area of interest for the T&D Certificate. As each course is developed and taught by a team of experienced engineers (from public and private utilities, consultants, and industry suppliers), students are provided a unique opportunity to interact directly with different industry experts over the eight weeks of each course. Course material incorporates advanced aspects of civil, electrical, and mechanical engineering disciplines that apply to power system design and are appropriate for graduate engineers. As such, target students for the certificate program include: (1) recent graduates with a Bachelor of Science Degree in an engineering field (civil, mechanical, electrical, etc.); (2) senior engineers moving from other fields to the utility industry (i.e. paper industry to utility engineering or project management positions); and (3) regular working

  20. Extragalactic circuits, transmission lines, and CR particle acceleration

    NASA Astrophysics Data System (ADS)

    Kronberg, Philipp P.; Lovelace, Richard V. E.

    2015-08-01

    A non-negligible fraction of a Supermassive Black Hole's (SMBH) rest mass energy gets transported into extragalactic space by a remarkable process in jets which are incompletely understood. What are the physical processes which transport this energy? It is likely that the energy flows electromagnetically, rather than via a particle beam flux. The deduced electromagnetic fields may produce particles of energy as high as ˜ 1020 eV. The energetics of SMBH accretion disk models and the electromagnetic energy transfer imply that a SMBH should generate a 1018 - 1019 Ampères current close to the black hole and its accretion disk. We describe the so far best observation-based estimate of the magnitude of the current flow along the axis of the jet extending from the nucleus of the active galaxy in 3C303. The current is measured to be I ˜ 1018 Ampères at ˜ 40 kpc away from the AGN. This indicates that organised current flow remains intact over multi-kpc distances. The electric current I transports electromagnetic power into free space, P = I2Z, where Z ˜ 30 Ohms is related to the impedance of free space, and this points to the existence of cosmic electric circuit. The associated electric potential drop, V = IZ, is of the order of that required to generate Ultra High Energy Cosmic Rays (UHECR). We also explore further implications, including disruption/deflection of the power flow and also why such measurements, exemplified by those on 3C303, are currently very difficult to make and to unambiguously interpret. This naturally leads to the topic of how such measurements can be extended and improved in the future. We describe the analogy of electromagnetically dominated jets with transmission lines. High powered jets in vacuo can be understood by approximate analogy with a waveguide. The importance of inductance, impedance, and other laboratory electrical concepts are discussed in this context.

  1. Recent progress of the improved magnetically insulated transmission line oscillator.

    PubMed

    Fan, Yu-Wei; Zhong, Hui-Huang; Li, Zhi-Qiang; Shu, Ting; Zhang, Jian-De; Liu, Jin-Liang; Yang, Jian-Hua; Zhang, Jun; Yuan, Cheng-Wei; Luo, Ling

    2008-03-01

    The improved magnetically insulated transmission line oscillator (MILO) is a gigawatt-class L-band high power microwave tube driven by a 550 kV, 57 kA, 50 ns electron beam. It has allowed us to generate 2.4 GW pulse of 22 ns duration. The recent progress of the improved MILO is presented in this paper. First, a field shaper cathode is introduced into the improved MILO to avoid the cathode flares in the triple point region. The experimental results show that the cathode flares are avoided, so the lifetime of the velvet cathode is longer than that of the taper cathode. Furthermore, the shot-to-shot reproducibility is better than that of the taper cathode. Second, In order to prolong the pulse duration and increase the radiated microwave power, a self-built 600 kV, 10 Omega, 80 ns pulser: SPARK-03 is employed to drive the improved MILO. Simulation and experimental investigation are performed. In simulation, when the improved MILO is driven by a 600 kV, 57 kA electron beam, high-power microwave is generated with output power of 4.15 GW, frequency of 1.76 GHz, and relevant power conversion efficiency of 12.0%. In experiments, when the diode voltage is 550 kV and current is 54 kA, the measured results are that the radiated microwave power is above 3.1 GW, the pulse duration is above 40 ns, the microwave frequency is about 1.755 GHz, and the power conversion efficiency is about 10.4%. PMID:18377036

  2. Electrical transmission lines in Montana: Mitigation of impacts to soil and biological sources

    SciTech Connect

    McCollough, S.A.; Ring, T.W.

    1990-12-31

    In Montana, the routing and construction of large electrical transmission lines are regulated by the Montana Major Facility Siting Act. Under this act, impacts to resources are minimized through avoidance by routing, where possible, and by mitigating remaining impacts. Land disturbed by the construction of transmission lines considered in this paper ranges from 1681 acres for a 500-kV line across 156 miles of mountainous terrain to 11 acres for a 100-kV line across 27 miles of nearly level terrain. Line access accounts for most of the disturbance, especially when graded roads are built in mountainous terrain. Land disturbed by transmission line construction is susceptible to soil erosion and weed infestation. These problems are addressed through revegetation, erosion control, and herbicide application. Transmission lines can displace wildlife from critical habitats by disruptive construction activities or by improving human access to previously secure range. Wildlife impacts can be reduced by restricting construction periods and gating roads.

  3. Explanation of the Inverse Doppler Effect Observed in Nonlinear Transmission Lines

    SciTech Connect

    Kozyrev, Alexander B.; Weide, Daniel W. van der

    2005-05-27

    The theory of the inverse Doppler effect recently observed in magnetic nonlinear transmission lines is developed. We explain the crucial role of the backward spatial harmonic in the occurrence of an inverse Doppler effect and draw analogies of the magnetic nonlinear transmission line to the backward wave oscillator.

  4. 49 CFR 192.713 - Transmission lines: Permanent field repair of imperfections and damages.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Transmission lines: Permanent field repair of...) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Maintenance § 192.713 Transmission lines: Permanent field repair of imperfections and damages. (a)...

  5. 49 CFR 192.713 - Transmission lines: Permanent field repair of imperfections and damages.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Transmission lines: Permanent field repair of...) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Maintenance § 192.713 Transmission lines: Permanent field repair of imperfections and damages. (a)...

  6. 49 CFR 192.715 - Transmission lines: Permanent field repair of welds.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Transmission lines: Permanent field repair of... SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Maintenance § 192.715 Transmission lines: Permanent field repair of welds. Each weld that is unacceptable...

  7. 49 CFR 192.713 - Transmission lines: Permanent field repair of imperfections and damages.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Transmission lines: Permanent field repair of...) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Maintenance § 192.713 Transmission lines: Permanent field repair of imperfections and damages. (a)...

  8. 49 CFR 192.717 - Transmission lines: Permanent field repair of leaks.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Transmission lines: Permanent field repair of... SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Maintenance § 192.717 Transmission lines: Permanent field repair of leaks. Each permanent field repair of a leak...

  9. 49 CFR 192.717 - Transmission lines: Permanent field repair of leaks.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Transmission lines: Permanent field repair of... SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Maintenance § 192.717 Transmission lines: Permanent field repair of leaks. Each permanent field repair of a leak...

  10. 49 CFR 192.715 - Transmission lines: Permanent field repair of welds.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Transmission lines: Permanent field repair of... SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Maintenance § 192.715 Transmission lines: Permanent field repair of welds. Each weld that is unacceptable...

  11. 49 CFR 192.717 - Transmission lines: Permanent field repair of leaks.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Transmission lines: Permanent field repair of... SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Maintenance § 192.717 Transmission lines: Permanent field repair of leaks. Each permanent field repair of a leak...

  12. 49 CFR 192.715 - Transmission lines: Permanent field repair of welds.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Transmission lines: Permanent field repair of... SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Maintenance § 192.715 Transmission lines: Permanent field repair of welds. Each weld that is unacceptable...

  13. 49 CFR 192.713 - Transmission lines: Permanent field repair of imperfections and damages.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Transmission lines: Permanent field repair of...) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Maintenance § 192.713 Transmission lines: Permanent field repair of imperfections and damages. (a)...

  14. 49 CFR 192.713 - Transmission lines: Permanent field repair of imperfections and damages.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Transmission lines: Permanent field repair of...) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Maintenance § 192.713 Transmission lines: Permanent field repair of imperfections and damages. (a)...

  15. View facing east (70°) of Transmission Line crossing Marias River, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View facing east (70°) of Transmission Line crossing Marias River, near Structure 47-9, grain elevators in town of Loma visible in background - Havre Rainbow Transmission Line, Havre City to Great Falls vicinity, Montana, Great Falls, Cascade County, MT

  16. Context view of RyantoRainbow 100kv Transmission Line showing copper wire ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Context view of Ryan-to-Rainbow 100kv Transmission Line showing copper wire conductors leaving roof of Ryan Powerhouse. View to east - Ryan Hydroelectric Facility, Ryan-to-Rainbow 100 kV Transmission Line, West bank of Missouri River, northeast of Great Falls, Great Falls, Cascade County, MT

  17. Some Little-Known Facts about Transmission Lines and Some New Results

    ERIC Educational Resources Information Center

    Dutta Roy, Suhash C.

    2010-01-01

    The study of transmission lines forms an integral part of any curriculum in electrical engineering. This paper presents some little-known but interesting facts about transmission lines, which are generally not found in textbooks, along with some new facts, which arose as extensions of these little-known ones. The facts highlighted in this paper…

  18. 75 FR 56051 - Bemidji to Grand Rapids Minnesota 230 kV Transmission Line Project

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-15

    ...; ] DEPARTMENT OF AGRICULTURE Rural Utilities Service Bemidji to Grand Rapids Minnesota 230 kV Transmission Line... Rapids, Minnesota 230 kV Transmission Line Project (``Project'') in Minnesota. The Final EIS was prepared... application of Minnkota Power Cooperative, Inc. for RUS financing to construct a 230 kilovolt...

  19. A calibration technique for measuring the complex permittivity of materials with planar transmission lines

    Technology Transfer Automated Retrieval System (TEKTRAN)

    A simple two-standard calibration procedure for determining the permittivity of a material from the propagation constant measured with planar transmission lines is presented. The suitability of this procedure is demonstrated by using a coplanar waveguide transmission-line sensor to measure the permi...

  20. PIPELINES, TRANSMISSION LINES, AND MISCELLANEOUS TRANSPORTATION FEATURES DIGITAL LINE GRAPHS FOR THE MID-ATLANTIC INTEGRATED ASSESSMENT (MAIA) STUDY AREA

    EPA Science Inventory

    This data set is a geographic information system (GIS) coverage of pipelines, transmission lines, and miscellaneous transportation features for the United States Environmental Protection Agency (USEPA) Mid-Atlantic Integrated Assessment (MAIA) Project region. The coverage was p...

  1. A study of electric transmission lines for use on the lunar surface

    NASA Technical Reports Server (NTRS)

    Gaustad, Krista L.; Gordon, Lloyd B.; Weber, Jennifer R.

    1994-01-01

    The sources for electrical power on a lunar base are said to include solar/chemical, nuclear (static conversion), and nuclear (dynamic conversion). The transmission of power via transmission lines is more practical than power beaming or superconducting because of its low cost and reliable, proven technology. Transmission lines must have minimum mass, maximum efficiency, and the ability to operate reliably in the lunar environment. The transmission line design includes conductor material, insulator material, conductor geometry, conductor configuration, line location, waveform, phase selection, and frequency. This presentation oulines the design. Liquid and gaseous dielectrics are undesirable for long term use in the lunar vacuum due to a high probability of loss. Thus, insulation for high voltage transmission line will most likely be solid dielectric or vacuum insulation.

  2. A study of electric transmission lines for use on the lunar surface

    NASA Astrophysics Data System (ADS)

    Gaustad, Krista L.; Gordon, Lloyd B.; Weber, Jennifer R.

    1994-09-01

    The sources for electrical power on a lunar base are said to include solar/chemical, nuclear (static conversion), and nuclear (dynamic conversion). The transmission of power via transmission lines is more practical than power beaming or superconducting because of its low cost and reliable, proven technology. Transmission lines must have minimum mass, maximum efficiency, and the ability to operate reliably in the lunar environment. The transmission line design includes conductor material, insulator material, conductor geometry, conductor configuration, line location, waveform, phase selection, and frequency. This presentation oulines the design. Liquid and gaseous dielectrics are undesirable for long term use in the lunar vacuum due to a high probability of loss. Thus, insulation for high voltage transmission line will most likely be solid dielectric or vacuum insulation.

  3. Omega transmission lines with applications to effective medium models of metamaterials

    NASA Astrophysics Data System (ADS)

    Vehmas, J.; Hrabar, S.; Tretyakov, S.

    2014-04-01

    In this paper, we introduce the concept of transmission lines with inherent bi-anisotropy and establish an analogy between these lines and volumetric bi-anisotropic materials. In particular, we find under what conditions a periodically loaded transmission line can be treated as an effective omega medium. Two example circuits are introduced and analyzed. The results have two-fold implications: opening a route to emulate electromagnetic properties of bi-anisotropic omega media using transmission-line meshes and understanding and improving effective medium models of composite materials with the use of effective circuit models of unit cells.

  4. Dielectric Resonator Transmission Line Models Employing the Generalized Telegraphist's Equation.

    NASA Astrophysics Data System (ADS)

    Gabbay, David

    1990-01-01

    A new comprehensive model that is applicable to both Dielectric Resonators (DR) and Dielectric Ring Resonators (DRR) has been developed. The dielectric resonator is typically a high dielectric constant material cylinder, where the ring resonator is modified by the addition of a concentric hole usually used for mounting. Both resonators are typically used in miniaturized high Q filtering at microwave and millimeter wave frequencies. The model is produced through a modal Fourier type expansion and results in a transmission line equivalent circuit. It is derived rigorously and its accuracy is not limited by a priori assumptions. However, a well selected set of basis functions achieves rapid convergence of the expansion series. It is therefore possible to truncate the modal expansion quite radically without greatly sacrificing its accuracy. Complete knowledge of the fields surrounding the resonator in association with the new model would provide an exact solution for the resonator network parameters. The concept of 'surface admittances' is introduced into the model formulation to represent the totality of the emanating and incident outside fields. As such, this technique allows the model to incorporate evanescent and radiating fields accurately. However, lacking an exact formulation for these fields, the derivation resorts to the use of approximations for the fields surrounding the resonator. The approximations are justifiable on physical grounds and allow a closed form treatment of the entire problem. The new model is used to predict the free-space resonance frequency and the results are compared to measured data and predictions which are based on other models. The predictions of the new model compare well with available data and illustrate some interesting phenomena associated with the dielectric resonator. This model is novel in that the equivalent circuit is derived with respect to the circular direction. The result is an equivalent circuit model possessing

  5. Transmission characteristics and transmission line model of a metal-insulator-metal waveguide with a stub modified by cuts.

    PubMed

    Shen, Xinru; Wang, Yueke; Yan, Xin; Yuan, Lin; Sang, Tian

    2016-08-10

    We propose a structure of a metal-insulator-metal (MIM) waveguide with a stub modified by cuts. Our simulation results, conducted by the finite element method, show that the wavelengths of transmission dip vary with the position of the cuts and form the zigzag lines. A transmission line model is also presented, and it agrees with simulation results well. It is believed that our findings provide a smart way to design a plasmonic waveguide filter at the communication region based on MIM structures. PMID:27534492

  6. Sensor, method and system of monitoring transmission lines

    DOEpatents

    Syracuse, Steven J.; Clark, Roy; Halverson, Peter G.; Tesche, Frederick M.; Barlow, Charles V.

    2012-10-02

    An apparatus, method, and system for measuring the magnetic field produced by phase conductors in multi-phase power lines. The magnetic field measurements are used to determine the current load on the conductors. The magnetic fields are sensed by coils placed sufficiently proximate the lines to measure the voltage induced in the coils by the field without touching the lines. The x and y components of the magnetic fields are used to calculate the conductor sag, and then the sag data, along with the field strength data, can be used to calculate the current load on the line and the phase of the current. The sag calculations of this invention are independent of line voltage and line current measurements. The system applies a computerized fitter routine to measured and sampled voltages on the coils to accurately determine the values of parameters associated with the overhead phase conductors.

  7. A real-time transmission line model for a digital TNA

    SciTech Connect

    Wang, X.; Woodford, D.A.; Kuffel, R.; Wierckx, R.

    1996-04-01

    This paper presents a validation of a real-time digital simulation of a transmission line model with frequency dependent parameters. The real-time transmission line model is based on Marti`s time domain formulation which is adopted in the EMTP and EMTDC programs. Improvements to speed up the calculation are made in order to realize electromagnetic transient simulation in real-time by parallel processing using two digital signal processors (DSP`s) for each line. 41 {micro}s and 71 {micro}s time steps are readily achieved in real time with the new line model for three phase and double circuit (6 conductors) transmission lines respectively. The new line model is now installed in a Real-Time Digital Simulator (RTDS). Field test results are presented in this paper for validating the new line model.

  8. Evaluation of Characteristics of Lightning Faults on 275kV Transmission Lines

    NASA Astrophysics Data System (ADS)

    Kawamura, Hironao; Itamoto, Naoki; Shinjo, Kazuo; Ishii, Masaru

    It is effective to design the lightning protection of transmission lines by employing simulation to be able to reproduce conditions of experienced lightning faults. As a result of the lightning faults on 275kV transmission lines in Hokuriku area, the frequency of only one-ground fault of upper or middle lines is higher. Especially, the frequency of one-ground faults of the middle lines in summer is the highest. It is thought that many one-ground faults in summer are caused by direct lightning strokes to phase conductors. Moreover, multi-ground faults caused by lightning strokes to tower tops or overhead ground wires also include many ground faults of the middle lines. In this paper, the experienced lightning faults on the 275kV transmission lines are reproduced by EMTP calculations and the characteristics of the ground-fault lines are examined.

  9. The effect analysis of strain rate on power transmission tower-line system under seismic excitation.

    PubMed

    Tian, Li; Wang, Wenming; Qian, Hui

    2014-01-01

    The effect analysis of strain rate on power transmission tower-line system under seismic excitation is studied in this paper. A three-dimensional finite element model of a transmission tower-line system is created based on a real project. Using theoretical analysis and numerical simulation, incremental dynamic analysis of the power transmission tower-line system is conducted to investigate the effect of strain rate on the nonlinear responses of the transmission tower and line. The results show that the effect of strain rate on the transmission tower generally decreases the maximum top displacements, but it would increase the maximum base shear forces, and thus it is necessary to consider the effect of strain rate on the seismic analysis of the transmission tower. The effect of strain rate could be ignored for the seismic analysis of the conductors and ground lines, but the responses of the ground lines considering strain rate effect are larger than those of the conductors. The results could provide a reference for the seismic design of the transmission tower-line system. PMID:25105157

  10. The Effect Analysis of Strain Rate on Power Transmission Tower-Line System under Seismic Excitation

    PubMed Central

    Wang, Wenming

    2014-01-01

    The effect analysis of strain rate on power transmission tower-line system under seismic excitation is studied in this paper. A three-dimensional finite element model of a transmission tower-line system is created based on a real project. Using theoretical analysis and numerical simulation, incremental dynamic analysis of the power transmission tower-line system is conducted to investigate the effect of strain rate on the nonlinear responses of the transmission tower and line. The results show that the effect of strain rate on the transmission tower generally decreases the maximum top displacements, but it would increase the maximum base shear forces, and thus it is necessary to consider the effect of strain rate on the seismic analysis of the transmission tower. The effect of strain rate could be ignored for the seismic analysis of the conductors and ground lines, but the responses of the ground lines considering strain rate effect are larger than those of the conductors. The results could provide a reference for the seismic design of the transmission tower-line system. PMID:25105157

  11. Research on UAV Intelligent Obstacle Avoidance Technology During Inspection of Transmission Line

    NASA Astrophysics Data System (ADS)

    Wei, Chuanhu; Zhang, Fei; Yin, Chaoyuan; Liu, Yue; Liu, Liang; Li, Zongyu; Wang, Wanguo

    Autonomous obstacle avoidance of unmanned aerial vehicle (hereinafter referred to as UAV) in electric power line inspection process has important significance for operation safety and economy for UAV intelligent inspection system of transmission line as main content of UAV intelligent inspection system on transmission line. In the paper, principles of UAV inspection obstacle avoidance technology of transmission line are introduced. UAV inspection obstacle avoidance technology based on particle swarm global optimization algorithm is proposed after common obstacle avoidance technologies are studied. Stimulation comparison is implemented with traditional UAV inspection obstacle avoidance technology which adopts artificial potential field method. Results show that UAV inspection strategy of particle swarm optimization algorithm, adopted in the paper, is prominently better than UAV inspection strategy of artificial potential field method in the aspects of obstacle avoidance effect and the ability of returning to preset inspection track after passing through the obstacle. An effective method is provided for UAV inspection obstacle avoidance of transmission line.

  12. A planar transmission-line sensor for measuring microwave permittivity of liquid and semisolid biological materials

    Technology Transfer Automated Retrieval System (TEKTRAN)

    An accurate technique for determining the permittivity of biological materials with coplanar waveguide transmission line is presented. The technique utilizes closed-form approximations that relate the material permittivity to the line propagation constant. A thru-reflect-line calibration procedure i...

  13. The development of a portable, automatic, microwave transmission line test set

    NASA Astrophysics Data System (ADS)

    de La Fuente, Val; Karuschkat, Glenn; Simone, Frederick

    Existing test sets for flightline testing of microwave transmission lines are complex, semiportable systems requiring the piece-part testing of waveguides, antennas, and transmission line components in the aircraft. Moreover, these systems are not fully automated and require a large degree of manual intervention. Therefore, advances in test-set miniaturization and automatic control techniques can now be utilized to develop a fully portable, automatic test set for the flightline functional and diagnostic fault isolation testing of RF avionics and microwave transmission lines. A description is given of the proposed capabilities of such a tester, and the benefits expected to be derived from its use.

  14. Some studies on carrier propagation in overhead transmission lines

    SciTech Connect

    Indulkar, C.S.; Kothari, D.P.; Kumar, P.

    1983-04-01

    The effectiveness of a carrier channel on a power line under various power frequency load conditions is studied. The effect of increase of load current results in an increase of conductor temperature, line length and sag. Therefore, the resistivity of the ACSR conductor material increases and the effective height of the conductor above the earth level decreases. A mathematical model of series-impedance and shunt-admittance which takes into account the above effects is used to evaluate the carrier signal attenuation on a line. Further, for the case of a bundle conductor line, the effect of subconductor deflections on the carrier attenuation has been studied. The effects of earth resistivity and earth wires on the actual carrier attenuation have also been studied.

  15. Hayden-Blue River 345-kV transmission line project, Colorado

    SciTech Connect

    Not Available

    1982-09-01

    Tri-State Generation and Transmission Association, Inc., Colorado-Ute Electric Association, Inc., Platte River Power Authority, and Western Area Power Administration propose to construct and operate approximately 90 miles of 345-kilovolt (kV) transmission line between Hayden and the Blue River Valley in Colorado. The project would involve expansion of existing substation facilities at Hayden and construction of two new substations. The line would be operated at 230 kV initially. Estimated cost of the project is $37.8 million. The new line and substation facilities would provide a backup transmission path, satisfy the long-term needs in meeting the energy requirements, improve system reliability, improve system stability for the Craig and Hayden generating stations, and leave the existing 115-kV and 138-kV lines in operation to provide additional transmission capacity that would function as backup transmission during an outage on another line. Minute amounts of lands would be displaced. Construction activities would disturb critical ranges for elk and mule deer, elk calving areas, and the mating and nesting areas of greater sandhill cranes, great blue herons, sage grouse, golden eagles, and prairie falcons. Management of timberland would damage natural vegetation. The line would traverse 3.1 miles of flood-prone area, and as many as three transmission towers would lie within the floodplain of the Colorado River. The visual quality of land crossed by the line would be degraded somewhat.

  16. A planar transmission-line sensor for measuring the microwave permittivity of liquid and semisolid biological materials

    Technology Transfer Automated Retrieval System (TEKTRAN)

    A planar transmission-line configuration for rapid, nondestructive, wideband permittivity measurements of liquid and semisolid materials at microwave frequencies is described. The transmission-line propagation constant of the proposed configuration is determined with the multiline technique from sca...

  17. Electric power high-voltage transmission lines: Design options, cost, and electric and magnetic field levels

    SciTech Connect

    Stoffel, J.B.; Pentecost, E.D.; Roman, R.D.; Traczyk, P.A.

    1994-11-01

    This report provides background information about (1) the electric and magnetic fields (EMFs) of high-voltage transmission lines at typical voltages and line configurations and (2) typical transmission line costs to assist on alternatives in environmental documents. EMF strengths at 0 {+-} 200 ft from centerline were calculated for ac overhead lines, and for 345 and 230-kV ac underground line and for a {+-}450-kV dc overhead line. Compacting and height sensitivity factors were computed for the variation in EMFs when line conductors are moved closer or raised. Estimated costs for the lines are presented and discussed so that the impact of using alternative strategies for reducing EMF strengths and the implications of implementing the strategies can be better appreciated.

  18. Performance analysis of radiation cooled dc transmission lines for high power space systems

    NASA Technical Reports Server (NTRS)

    Schwarze, G. E.

    1985-01-01

    As space power levels increase to meet mission objectives and also as the transmission distance between power source and load increases, the mass, volume, power loss, and operating voltage and temperature become important system design considerations. This analysis develops the dependence of the specific mass and percent power loss on the power and voltage levels, transmission distance, operating temperature and conductor material properties. Only radiation cooling is considered since the transmission line is assumed to operate in a space environment. The results show that the limiting conditions for achieving low specific mass, percent power loss, and volume for a space-type dc transmission line are the permissible transmission voltage and operating temperature. Other means to achieve low specific mass include the judicious choice of conductor materials. The results of this analysis should be immediately applicable to power system trade-off studies including comparisons with ac transmission systems.

  19. Performance analysis of radiation cooled dc transmission lines for high power space systems

    NASA Technical Reports Server (NTRS)

    Schwarze, G. E.

    1985-01-01

    As space power levels increase to meet mission objectives and also as the transmission distance between power source and load increases, the mass, volume, power loss, and operating voltage and temperature become important system design considerations. This analysis develops the dependence of the specific mass and percent power loss on hte power and voltage levels, transmission distance, operating temperature and conductor material properties. Only radiation cooling is considered since the transmission line is assumed to operate in a space environment. The results show that the limiting conditions for achieving low specific mass, percent power loss, and volume for a space-type dc transmission line are the permissible transmission voltage and operating temperature. Other means to achieve low specific mass include the judicious choice of conductor materials. The results of this analysis should be immediately applicable to power system trade-off studies including comparisons with ac transmission systems.

  20. PennsylvaniaNew Jersey Interconnection Bushkill to Roseland Transmission Line, From Roseland ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Pennsylvania-New Jersey Interconnection Bushkill to Roseland Transmission Line, From Roseland Borough, Essex County, through Morris County and Sussex County to Hardwick Township, Warren County, Roseland, Essex County, NJ

  1. Coyote Pumping Plant 115-kV transmission line project, Santa Clara County, California: Environmental assessment

    SciTech Connect

    Not Available

    1985-01-01

    Environmental impacts expected from the design and siting of transmission lines and the associated pumping plant station are addressed with alternative routes and actions considered, in compliance with environmental laws. (PSB)

  2. Effect of variability in weather conditions on conductor temperature and the dynamic rating of transmission lines

    SciTech Connect

    Foss, S.D.; Lin, S.H. ); Maraio, R.A.; Schrayshuen, H. )

    1988-10-01

    Simultaneous weather and conductor data were collected from these locations situated in New York State and Western Massachusetts. The two New York State locations represent the termination points of a 230 kV seventy-mile overhead line. The transmission line consists of a Drake 795 kcmil ACSR conductor. Data were monitored using on-line sensor equipment developed by the Research and Development Department of the Niagara Mohawk Power Corporation. The purposes of the investigation were to analyze variability in weather conditions, conductor temperature and calculated dynamic ratings that exist along transmission lines. Reported here are variabilities in air temperature, wind speed, conductor current, conductor surface temperature and calculated dynamic ratings.

  3. Frequency Selective Properties of Coaxial Transmission Lines Loaded with Combined Artificial Inclusions

    PubMed Central

    2014-01-01

    The properties of a modified coaxial transmission line by periodic inclusions will be discussed. The introduction of split ring resonators, conductor stubs, air gaps, and combination of these gives rise to new frequency selective properties, such as stopband or passband behavior, observable in planar as well as volumetric metamaterial structures. These results envisage new potential applications and implementation of devices in coaxial transmission line technology. PMID:24587748

  4. Optimized Minimal Inductance Transmission Line Configuration for Z-Pinch Experiments

    SciTech Connect

    Hurricane, O

    2003-10-16

    Successful dynamic Z-pinch experiments generally require good current delivery to the target load. Power flow losses through highly inductive transmission line configurations reduce the current available to the load. In this Brief Report, a variational calculus technique is used to determine the transmission line configuration that produces the least possible inductance and therefore the best possible current delivery for Z-pinch experiments.

  5. Finite-difference, time-domain analysis of a folded acoustic transmission line.

    PubMed

    Jackson, Charles M

    2005-03-01

    Recently designed, modern versions of renais sance woodwind instruments such as the recorder and serpent use square cross sections and a folded acoustic transmission line. Conventional microwave techniques would expect that this bend would cause unwanted reflections and impedance discontinuities. This paper analyses the folded acoustic transmission line using finite-difference, time-domain techniques and shows that the discontinuity can be compensated with by the use of a manufacturable method. PMID:15857045

  6. TE sub r azimuthal modes for a biconic transmission line in the small-gap limit

    SciTech Connect

    Johnson, W.A.; Mendel, C.W. Jr.; Seidel, D.B. )

    1992-04-15

    Azimuthally asymmetric modes in a biconic transmission line with a small-gap angle may be approximated by transmission-line-like'' modes. It is shown that the errors in these approximations are second order in the gap angle and approximate error bounds are provided. As an example demonstrating the application of this analysis in biconic structures, an analysis to characterize of the electromagnetic waves in the vacuum feed of the Particle Beam Fusion Accelerator II is provided.

  7. First structure on MoronytoRainbow 100kV Transmission Line below Morony Dam ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    First structure on Morony-to-Rainbow 100kV Transmission Line below Morony Dam and Power House. Three-pole H-frame structure with historic porcelain suspension insulators, jumper supports insulators, overhead ground wires, and pole stubs. View to east-northeast - Morony Hydroelectric Facility, Morony-to-Rainbow 100 kV Transmission Line, West bank of the Missouri River, Great Falls, Cascade County, MT

  8. Multisection transmission line scatter function theory for measurements of soil dielectric properties

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Vector network analyzers measure both reflection (S11) and transmission (S21) functions, but S21 has not been used to estimate soil dielectric permittivity independently. The objectives of this study were to: (1) derive the mathematical model for S21 of a multisection transmission line, and (2) tes...

  9. 49 CFR 192.711 - Transmission lines: General requirements for repair procedures.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... pipeline covered under Subpart O-Gas Transmission Pipeline Integrity Management, the operator must... 49 Transportation 3 2014-10-01 2014-10-01 false Transmission lines: General requirements for...) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY...

  10. 49 CFR 192.711 - Transmission lines: General requirements for repair procedures.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... pipeline covered under Subpart O-Gas Transmission Pipeline Integrity Management, the operator must... 49 Transportation 3 2011-10-01 2011-10-01 false Transmission lines: General requirements for...) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY...

  11. 49 CFR 192.711 - Transmission lines: General requirements for repair procedures.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... pipeline covered under Subpart O-Gas Transmission Pipeline Integrity Management, the operator must... 49 Transportation 3 2012-10-01 2012-10-01 false Transmission lines: General requirements for...) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND OTHER GAS BY PIPELINE: MINIMUM FEDERAL SAFETY...

  12. Analysis of optimum diameter of orbit of transmission line source in positron emission tomograph

    SciTech Connect

    Yamamoto, S.; Amano, M.; Hirose, Y.; Muira, S.; Kanno, I.

    1989-02-01

    Accurate attenuation correction is one of the most important factors to achieve quantitative measurements in positron emission tomography (PET). A transmission scan is most commonly used technique for the attenuation correction in PET. A difficulty in transmission scan is relatively long period to obtain a data with good signal-to-noise ratio. Insufficient signal-to-noise ratio of the transmission data limits that of emission data. Several approaches were reported to improve the transmission data. Those were (1) optimizing of detector threshold, (2) processing delayed coincidence sinogram before subtraction, filtering of transmission sinogram before performing attenuation correction, and (3) rejection of random and scatter coincidence by using rotating line source and information of its position. In some of these methods, additional calculation time or processing hardware is needed. The authors have estimated a relationship between ring diameter of a transmission line source and signal to noise ratio of the transmission dat. This paper aimes to analyze optimum diameter of the orbit of transmission line source in concerning to signal to noise ratio in transmission data.

  13. Transmission line switch design for the investigation of sub-nanosecond electrical breakdown

    NASA Astrophysics Data System (ADS)

    Dick, A. R.; MacGregor, S. J.; Pate, R. C.

    2002-04-01

    Ultrafast plasma closing switches rely on sub-nanosecond electrical breakdown of the insulating gas. Until recently, little information was available on gas breakdown occurring within this timescale, because of the difficulties in designing an experimental system for such a study. Recently published papers have reported on the results of studies carried out using two devices designed specifically for the investigation of fast (sub-nanosecond) electrical breakdown processes. The devices are essentially modified transmission line plasma closing switches, and in this paper we describe their structure and operation. Because electromagnetic wave behaviour plays a significant role in sub-nanosecond switching, especially reflections from impedance mismatches, the design of the devices is based on transmission line concepts, rather than those of lumped parameters. One of the switches has a conical transmission line topology and is designed for the study of fast switch closure at insulating gas pressures less than 0.6 MPa. The second has a hybrid radial transmission line/conical transmission line topology and is designed for the study of fast switch closure at pressures up to 10 MPa. The paper also includes details of the D-dot monitors used to investigate sub-nanosecond processes in the two transmission line plasma devices.

  14. Transmission line galloping image monitoring system based on digital signal processor

    NASA Astrophysics Data System (ADS)

    Ren, Hai Peng; Ma, Zhan Feng

    2011-06-01

    An embedded image monitoring system based on TMS320DM642 Digital Signal Processor (DSP) is proposed for the transmission line monitoring. The system can detect galloping, ice or snow covering, and other abnormal status of the transmission line in a real time mode. The image detection algorithms are compared using the controlled experiment under the complex weather environment, thereby, a set of image processing algorithms is proposed for transmission lines image monitoring. The DSP/BOIS multi-threaded programming techniques are used to realize the algorithm in the DSPs' embedded software. A wireless communication based on General Packet Radio Service (GPRS) module is designed to transmit the detection results and the changed information of the image to the monitoring center, so that the operators can get the real time status of the transmission line. The application of the system will play an important role in the condition-based maintenance of power transmission lines and improve the reliability of power delivery system. Transmission line; Status monitoring; Complex weather factor; Image filtering and sharpening; Image segment; Morphological filtering; Wireless communication; Digital signal processor; Multi-threaded programming.

  15. Millikelvin thermal and electrical performance of lossy transmission line filters

    SciTech Connect

    Slichter, Daniel; Naaman, Ofer; Siddiqi, Irfan

    2009-03-11

    We report on the scattering parameters and Johnson noise emission of low-pass stripline filters employing a magnetically loaded silicone dielectric down to 25 mK. The transmission characteristic of a device with f-3dB=1.3 GHz remains essentially unchanged upon cooling. Another device with f-edB=0.4 GHz, measured in its stopband, exhibits a steady state noise power emission consistent with a temperature difference of a few mK relative to a well-anchored cryogenic microwave attenuator at temperatures down to 25 mK, thus presenting a matched thermal load.

  16. Traveling-wave pulse on a superconductive active transmission line using resonant tunneling diodes

    NASA Astrophysics Data System (ADS)

    Klofaï, Yerima; Essimbi, B. Z.; Jäger, D.

    2013-10-01

    Analytic study and computer experiment investigations on a superconductive active transmission line using resonant tunneling diodes (RTDs) are discussed. It is shown, based on nonlinear wave propagation effects, that the line supports pulse propagation appearing as pairs of kink-antikink profiles. This behavior is due to compensation between the effects of amplification and dissipation along the network.

  17. 75 FR 19963 - Florida Gas Transmission Company, LLC; Transcontinental Gas Pipe Line Company, LLC; Florida Gas...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-16

    ... Energy Regulatory Commission Florida Gas Transmission Company, LLC; Transcontinental Gas Pipe Line... Transcontinental Gas Pipe Line Company, LLC (Transco) in the above referenced dockets. The EA assesses the... pig launcher in Grand Bay, Alabama (MP 8.8); One new Over Pressure Protection Regulator Station...

  18. Measuring the complex permittivity of poultry meat with a planar transmission-line sensor

    Technology Transfer Automated Retrieval System (TEKTRAN)

    A planar transmission-line sensor is used to measure the complex permittivity of chicken breast meat over the frequency range 0.5 – 5 GHz. Results for the permittivity of nine samples of chicken breast meat are compared to results obtained with a commercially available open-ended coaxial-line probe....

  19. Political efficacy and familiarity as predictors of attitudes towards electric transmission lines in the United States

    DOE PAGESBeta

    Joe, Jeffrey C.; Hendrickson, Kelsie; Wong, Maria; Kane, Stephanie L.; Solan, David; Carlisle, Juliet E.; Koehler, David; Ames, Daniel P.; Beazer, Robert

    2016-05-18

    Public opposition to the construction (i.e., siting) of new high voltage overhead transmission lines is not a new or isolated phenomenon. Past research has posited a variety of reasons, applied general theories, and has provided empirical evidence to explain public opposition. The existing literature, while clarifying many elements of the issue, does not yet fully explain the complexities underlying this public opposition phenomenon. As a result, the current study demonstrated how two overlooked factors, people’s sense of political efficacy and their familiarity (i.e., prior exposure) with transmission lines, explained attitudes of support and opposition to siting new power lines.

  20. Transmission line design for a power distribution system at 20 kHz for aircraft

    NASA Technical Reports Server (NTRS)

    Zelby, L. W.; Mathes, J. B.; Shawver, J. W.

    1986-01-01

    A low inductance, low characteristic impedance transmission line was designed for a 20 kHz power distribution system. Several different conductor configurations were considered: strip lines, interdigitated metal ribbons, and standard insulated wires in multiwire configurations (circular and rectangular cylindrical arrangements). The final design was a rectangular arrangement of multiple wires of the same gauge with alternating polarities from wire to wire. This offered the lowest inductance per unit length (on the order of several nanohenries/meter) and the lowest characteristic impedance (on the order of one Ohm). Standard multipin connectors with gold-plated elements were recommended with this transmission line, the junction boxes to be internally connected with flat metal ribbons for low inductance, and the line to be constructed in sections of suitable length. Computer programs for the calculation of inductance of multiwire lines and of capacitances of strip lines were developed.

  1. Fiber Optic Picosecond Laser Pulse Transmission Line for Hydrogen Ion Beam Profile Measurement

    SciTech Connect

    Liu, Yun; Huang, Chunning; Aleksandrov, Alexander V

    2013-01-01

    We present a fiber optic laser pulse transmission line for non-intrusive longitudinal profile measurement of the hydrogen ion (H-) beam at the front-end of the Spallation Neutron Source (SNS) accelerator. The 80.5 MHz, 2.5 ps, multi-killowatt optical pulses are delivered to the accelerator beam line through a large mode area polarization maintaining optical fiber to ensure a high measurement stability. The transmission efficiency, output laser beam quality, pulse jitter and pulse width broadening over a 100-ft fiber line are experimentally investigated. A successful measurement of the H- beam microbunch (~130 ps) profile is obtained. Our experiment is the first demonstration of particle beam profile diagnostics using fiber optic laser pulse transmission line.

  2. Nanoscale broadband transmission lines for spin qubit control

    NASA Astrophysics Data System (ADS)

    Dehollain, J. P.; Pla, J. J.; Siew, E.; Tan, K. Y.; Dzurak, A. S.; Morello, A.

    2013-01-01

    The intense interest in spin-based quantum information processing has caused an increasing overlap between the two traditionally distinct disciplines of magnetic resonance and nanotechnology. In this work we discuss rigorous design guidelines to integrate microwave circuits with charge-sensitive nanostructures, and describe how to simulate such structures accurately and efficiently. We present a new design for an on-chip, broadband, nanoscale microwave line that optimizes the magnetic field used to drive a spin-based quantum bit (or qubit) while minimizing the disturbance to a nearby charge sensor. This new structure was successfully employed in a single-spin qubit experiment, and shows that the simulations accurately predict the magnetic field values even at frequencies as high as 30 GHz.

  3. Assessment of Fecundity and Germ Line Transmission in Two Transgenic Pig Lines Produced by Sleeping Beauty Transposition

    PubMed Central

    Garrels, Wiebke; Holler, Stephanie; Cleve, Nicole; Niemann, Heiner; Ivics, Zoltan; Kues, Wilfried A.

    2012-01-01

    Recently, we described a simplified injection method for producing transgenic pigs using a non-autonomous Sleeping Beauty transposon system. The founder animals showed ubiquitous expression of the Venus fluorophore in almost all cell types. To assess, whether expression of the reporter fluorophore affects animal welfare or fecundity, we analyzed reproductive parameters of two founder boars, germ line transmission, and organ and cell specific transgene expression in animals of the F1 and F2 generation. Molecular analysis of ejaculated sperm cells suggested three monomeric integrations of the Venus transposon in both founders. To test germ line transmission of the three monomeric transposon integrations, wild-type sows were artificially inseminated. The offspring were nursed to sexual maturity and hemizygous lines were established. A clear segregation of the monomeric transposons following the Mendelian rules was observed in the F1 and F2 offspring. Apparently, almost all somatic cells, as well as oocytes and spermatozoa, expressed the Venus fluorophore at cell-type specific levels. No detrimental effects of Venus expression on animal health or fecundity were found. Importantly, all hemizygous lines expressed the fluorophore in comparable levels, and no case of transgene silencing or variegated expression was found after germ line transmission, suggesting that the insertions occurred at transcriptionally permissive loci. The results show that Sleeping Beauty transposase-catalyzed transposition is a promising approach for stable genetic modification of the pig genome. PMID:24705079

  4. Marys Lake 69/115-kV transmission line upgrade and substation expansion projects

    SciTech Connect

    1996-05-01

    Western Area Power Administration (Western) and the Platte River Power Authority (Platte River) propose to upgrade portions of the existing electric transmission and substation system that serves the Town of Estes Park, Colorado. The existing transmission lines between the Estes Power Plant Switchyard and the Marys Lake Substation include a 115,000 volt (115-kV) line and 69,000 volt (69-kV) line. Approximately one mile is a double-circuit 115/69-kV line on steel lattice structures, and approximately two miles consists of separate single-circuit 115-kV and a 69-kV lines, constructed on wood H-Frame structures. Both lines were constructed in 1951 by the US Bureau of Reclamation. The existing transmission lines are on rights-of-way (ROW) that vary from 75 feet to 120 feet and are owned by Western. There are 48 landowners adjacent to the existing ROW. All of the houses were built adjacent to the existing ROW after the transmission lines were constructed. Upgrading the existing 69-kV transmission line between the Marys Lake Substation and the Estes Power Plant Switchyard to 115-kV and expanding the Marys Lake Substation was identified as the most effective way in which to improve electric service to Estes Park. The primary purpose and need of the proposed project is to improve the reliability of electric service to the Town of Estes Park. Lack of reliability has been a historical concern, and reliability will always be less than desired until physical improvements are made to the electrical facilities serving Estes Park.

  5. Preliminary evaluation of space station transmission line in a ring configuration

    NASA Technical Reports Server (NTRS)

    Roth, Mary Ellen

    1990-01-01

    The results of a preliminary evaluation of a space station type transmission line and commercial transmission lines in a ring configuration, are reported. In a ring configuration, each node has two paths for the return current of each wire. The additional path can create an unbalanced condition, where the magnetic fields created by the forward and return currents do not cancel. This evaluation was to quantify the effects of the unbalanced case upon the external fields. The transmission lines evaluated were standard commercial coaxial cables, RG59 and RG213, and a space station designed flat Litz transmission line. Each was evaluated in a balanced and unbalanced mode of operation. Currents and their harmonic content were recorded and compared. As expected, the harmonic content of the different current (I delta) was substantial for the unbalanced case as compared to the balanced case. For the balanced case, very little difference was noted among the various transmission lines evaluated. The evaluation is discussed, and the test circuit, the measurements, and the resulting data are described.

  6. Study of transmission line attenuation in broad band millimeter wave frequency range

    NASA Astrophysics Data System (ADS)

    Pandya, Hitesh Kumar B.; Austin, M. E.; Ellis, R. F.

    2013-10-01

    Broad band millimeter wave transmission lines are used in fusion plasma diagnostics such as electron cyclotron emission (ECE), electron cyclotron absorption, reflectometry and interferometry systems. In particular, the ECE diagnostic for ITER will require efficient transmission over an ultra wide band, 100 to 1000 GHz. A circular corrugated waveguide transmission line is a prospective candidate to transmit such wide band with low attenuation. To evaluate this system, experiments of transmission line attenuation were performed and compared with theoretical loss calculations. A millimeter wave Michelson interferometer and a liquid nitrogen black body source are used to perform all the experiments. Atmospheric water vapor lines and continuum absorption within this band are reported. Ohmic attenuation in corrugated waveguide is very low; however, there is Bragg scattering and higher order mode conversion that can cause significant attenuation in this transmission line. The attenuation due to miter bends, gaps, joints, and curvature are estimated. The measured attenuation of 15 m length with seven miter bends and eighteen joints is 1 dB at low frequency (300 GHz) and 10 dB at high frequency (900 GHz), respectively.

  7. Calculation of transmission line impedances using the ANSYS finite element program

    SciTech Connect

    Johnson, M.E.

    1984-06-29

    This paper describes numerical techniques for calculating the capacitance of an arbitrary two conductor structure. For two dimensional structures the capacitance per unit length can be easily related to the characteristic impedance of a transmission line with the same cross section. Note that this is true for lines operated below their cut off frequency, i.e., TEM mode only. Thus, one can compute the impedance of an arbitrarily shaped line. The method using the ANSYS finite element program is being used to design the high voltage transmission line for the Yale streamer chamber. This line has a transition piece between two different cross sections. It is being modeled by taking several slices throughout the transition region.

  8. Effects of high-voltage transmission lines on honey bees

    SciTech Connect

    Greenberg, B.; Bindokas, V.P.

    1981-04-01

    Data are reported on the effect of hive height and current distribution on honey bees hived under a 765 kV line (E-field ca. 7 kV/m). Hive height was standardized with adjustable collectors to 1 meter (59 ..mu..A total hive current) or 1.5 meter (85 ..mu..A) equivalents; controls were shielded. A 1.5 meter group with completely painted supers was included. After 8 or 16 weeks of exposure there was no effect on honey moisture content or weight of young workers in any group. Worker capped brood was not affected in 1 m hives but declined significantly in 1.5 m hives after 4 weeks of exposure and this was associated with queen loss, abnormal queen cell production, and colony failure. Weight gain was depressed in all hives after 2 weeks of exposure and was dose related, with the taller hives more severely affected. Only the exposed hives propolized entrances but the amount and time of onset were not dose related. The 1.5 m hives with painted interiors behaved like the 1 m hives with unpainted interiors in all respects, although their total hive current approximated the other group of 1.5 m hives. Reversal of treatments at midseason resulted in reversal of colony behavior, manifested most clearly with respect to hive weight, less with respect to brood. When first exposed, colonies exhibit pronounced but transient elevations in hive temperature. Bio-effects were more severe during the first period when hives had fewer bees. Total hive current was greater in wet than in dry periods. All these factors influence observed bioeffects.

  9. Dynamic responses and vibration control of the transmission tower-line system: a state-of-the-art review.

    PubMed

    Chen, Bo; Guo, Wei-hua; Li, Peng-yun; Xie, Wen-ping

    2014-01-01

    This paper presented an overview on the dynamic analysis and control of the transmission tower-line system in the past forty years. The challenges and future developing trends in the dynamic analysis and mitigation of the transmission tower-line system under dynamic excitations are also put forward. It also reviews the analytical models and approaches of the transmission tower, transmission lines, and transmission tower-line systems, respectively, which contain the theoretical model, finite element (FE) model and the equivalent model; shows the advances in wind responses of the transmission tower-line system, which contains the dynamic effects under common wind loading, tornado, downburst, and typhoon; and discusses the dynamic responses under earthquake and ice loads, respectively. The vibration control of the transmission tower-line system is also reviewed, which includes the magnetorheological dampers, friction dampers, tuned mass dampers, and pounding tuned mass dampers. PMID:25105161

  10. Dynamic Responses and Vibration Control of the Transmission Tower-Line System: A State-of-the-Art Review

    PubMed Central

    Chen, Bo; Guo, Wei-hua; Li, Peng-yun; Xie, Wen-ping

    2014-01-01

    This paper presented an overview on the dynamic analysis and control of the transmission tower-line system in the past forty years. The challenges and future developing trends in the dynamic analysis and mitigation of the transmission tower-line system under dynamic excitations are also put forward. It also reviews the analytical models and approaches of the transmission tower, transmission lines, and transmission tower-line systems, respectively, which contain the theoretical model, finite element (FE) model and the equivalent model; shows the advances in wind responses of the transmission tower-line system, which contains the dynamic effects under common wind loading, tornado, downburst, and typhoon; and discusses the dynamic responses under earthquake and ice loads, respectively. The vibration control of the transmission tower-line system is also reviewed, which includes the magnetorheological dampers, friction dampers, tuned mass dampers, and pounding tuned mass dampers. PMID:25105161

  11. Lumped-element model of a tapered transmission line for impedance matching in a pulsed power system

    NASA Astrophysics Data System (ADS)

    Lee, Kun-A.; Ko, Kwang-Cheol

    2016-07-01

    In a pulsed power system, impedance matching is one of the significant factors for increasing the efficiency of the system. One of the most general methods for impedance matching is to use a tapered transmission line. Because the characteristics of a tapered transmission line are changed continuously according to its position, modeling the tapered transmission line by using lumped elements is difficult. In this study, we investigated a tapered transmission line to match the impedance of power supply to that of a load by using lumped elements especially in a pulsed power system. In modeling the tapered transmission line, we used the concept of a transmission, and we introduced an efficient modeling method. We propose a simulation model based on the investigation results. The results of the study will be useful for research on tapered transmission lines.

  12. Design of the Transmission Lines for 140 GHz ECRH System on HL-2A

    NASA Astrophysics Data System (ADS)

    Xia, Donghui; Zhou, Jun; Rao, Jun; Huang, Mei; Lu, Zhihong; Wang, He; Chen, Gangyu; Wang, Chao; Lu, Bo; Zhuang, Ge

    2014-03-01

    A new 140 GHz/2 MW/3 s electron cyclotron resonance heating (ECRH) system composed of two units is now being constructed on HL-2A. As a part of the system, two transmission lines marked No.7 & 8 play the role of carrying microwave power from two gyrotrons to the tokamak port. Based on the oversized circular corrugated waveguide technology, an evacuated transmission system with high power capability and high transmission efficiency is designed. Details are presented for the design of the corrugated waveguide, the layout of the proposed lines and the vacuum pumping system. Then mode conversion losses due to coupling, misalignment, bends and gaps are discussed to serve as a reference for analyzing the transmission efficiency and alignment. Finally, a dual-modes propagation case consisting of the HE11 and LP11 even modes is discussed.

  13. 75 FR 32940 - Request for Proposals for New or Upgraded Transmission Line Projects Under Section 1222 of the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-10

    ... Transmission Line Projects under section 1222 of EPAct (73 FR 70636 and 70638 respectively). Southwestern... Western's participation in the upgrade of existing transmission facilities owned by either PMA, or the construction of new transmission lines in the states in which either PMA operates. DATES: Project...

  14. Transmission Line Jobs and Economic Development Impact (JEDI) Model User Reference Guide

    SciTech Connect

    Goldberg, M.; Keyser, D.

    2013-10-01

    The Jobs and Economic Development Impact (JEDI) models, developed through the National Renewable Energy Laboratory (NREL), are freely available, user-friendly tools that estimate the potential economic impacts of constructing and operating power generation projects for a range of conventional and renewable energy technologies. The Transmission Line JEDI model can be used to field questions about the economic impacts of transmission lines in a given state, region, or local community. This Transmission Line JEDI User Reference Guide was developed to provide basic instruction on operating the model and understanding the results. This guide also provides information on the model's underlying methodology, as well as the parameters and references used to develop the cost data contained in the model.

  15. High-Power Ka-Band Transmission Line with a Frequency Bandwidth of 1 GHZ

    NASA Astrophysics Data System (ADS)

    Bogdashov, A. A.; Denisov, G. G.; Samsonov, S. V.; Gachev, I. G.; Dominyuk, Ya. V.; Murzin, V. N.; Levitan, B. A.

    2016-03-01

    We present experimental results on a high-power transmission line from the broadband pulsed Ka-band gyro-TWT to the phased antenna array. The transmission line is designed to operate in a pulse-periodic regime with a pulse width of up to 250 μs, a duty factor of 8, and an average output power of up to 15 kW. Amplitude-frequency and phase-frequency characteristics of the transmission line were measured at a low power level. It is shown that the nonlinearity of the phase-frequency characteristic does not exceed ±10° in the 34 ± 0.5 GHz frequency band.

  16. Non-Linear Transmission Line (NLTL) Microwave Source Lecture Notes the United States Particle Accelerator School

    SciTech Connect

    Russell, Steven J.; Carlsten, Bruce E.

    2012-06-26

    We will quickly go through the history of the non-linear transmission lines (NLTLs). We will describe how they work, how they are modeled and how they are designed. Note that the field of high power, NLTL microwave sources is still under development, so this is just a snap shot of their current state. Topics discussed are: (1) Introduction to solitons and the KdV equation; (2) The lumped element non-linear transmission line; (3) Solution of the KdV equation; (4) Non-linear transmission lines at microwave frequencies; (5) Numerical methods for NLTL analysis; (6) Unipolar versus bipolar input; (7) High power NLTL pioneers; (8) Resistive versus reactive load; (9) Non-lineaer dielectrics; and (10) Effect of losses.

  17. Kinetic inductance driven nanoscale 2D and 3D THz transmission lines.

    PubMed

    Mousavi, S Hossein; Williamson, Ian A D; Wang, Zheng

    2016-01-01

    We examine the unusual dispersion and attenuation of transverse electromagnetic waves in the few-THz regime on nanoscale graphene and copper transmission lines. Conventionally, such propagation has been considered to be highly dispersive, due to the RC time constant-driven voltage diffusion below 1 THz and plasmonic effects at higher optical frequencies. Our numerical modeling across the microwave, THz, and optical frequency ranges reveals that the conductor kinetic inductance creates an ultra-broadband linear-dispersion and constant-attenuation region in the THz regime. This so-called LC region is an ideal characteristic that is known to be absent in macro-scale transmission lines. The kinetic-LC frequency range is dictated by the structural dimensionality and the free-carrier scattering rate of the conductor material. Moreover, up to 40x wavelength reduction is observed in graphene transmission lines. PMID:27137628

  18. Kinetic inductance driven nanoscale 2D and 3D THz transmission lines

    NASA Astrophysics Data System (ADS)

    Mousavi, S. Hossein; Williamson, Ian A. D.; Wang, Zheng

    2016-05-01

    We examine the unusual dispersion and attenuation of transverse electromagnetic waves in the few-THz regime on nanoscale graphene and copper transmission lines. Conventionally, such propagation has been considered to be highly dispersive, due to the RC time constant-driven voltage diffusion below 1 THz and plasmonic effects at higher optical frequencies. Our numerical modeling across the microwave, THz, and optical frequency ranges reveals that the conductor kinetic inductance creates an ultra-broadband linear-dispersion and constant-attenuation region in the THz regime. This so-called LC region is an ideal characteristic that is known to be absent in macro-scale transmission lines. The kinetic-LC frequency range is dictated by the structural dimensionality and the free-carrier scattering rate of the conductor material. Moreover, up to 40x wavelength reduction is observed in graphene transmission lines.

  19. Onset of dispersion in Nb microstrip transmission lines at submillimeter wave frequencies

    NASA Technical Reports Server (NTRS)

    Javadi, H. H. S.; Mcgrath, William R.; Bumble, B.; Leduc, Henry G.

    1992-01-01

    We have measured the dispersion in phase velocity of a Nb-SiO(x)-Nb microstrip transmission line resonator over a frequency range from 50 GHz to 800 GHz. A submicron Nb/Al-AlO(x)/Nb Josephson junction was used as a voltage-controlled oscillator to excite the high order modes in the resonator. The same junction is used as a direct detector resulting in a series of step-like structures in the DC current-voltage characteristic at the position of each mode frequency. The transmission line is dispersionless up to about 500 GHz where the phase velocity begins to decrease. This is well below the gap frequency f(sub g) approx. equals 700 GHz. Results agree qualitatively with the expected theoretical behavior near f(sub g). This onset of dispersion and loss in Nb transmission lines will have a significant impact on the design of submillimeter wave RF circuits.

  20. Computer simulation of multiple coupled transmission lines in electronic packaging application

    SciTech Connect

    Liao, Jenchyi.

    1989-01-01

    A method for simulating the transient responses of networks containing lossless transmission lines and lumped parameter elements of circuits, both linear and nonlinear, has been developed and investigated. The method combines the technique of network analysis and that of modal decomposition of transmission lines. A prototype computer simulation program, called UANTL, based on the developed algorithm has been implemented. Several example networks have been simulated using this program. The results have been compared with those generated by the well known circuit simulator program called SPICE. UANTL has shown several advantages over SPICE in simulating the transient responses of networks containing transmission lines. A description of the prototype version of UANTL and a summary of the results of numerical experiments are included.

  1. Kinetic inductance driven nanoscale 2D and 3D THz transmission lines

    PubMed Central

    Mousavi, S. Hossein; Williamson, Ian A. D.; Wang, Zheng

    2016-01-01

    We examine the unusual dispersion and attenuation of transverse electromagnetic waves in the few-THz regime on nanoscale graphene and copper transmission lines. Conventionally, such propagation has been considered to be highly dispersive, due to the RC time constant-driven voltage diffusion below 1 THz and plasmonic effects at higher optical frequencies. Our numerical modeling across the microwave, THz, and optical frequency ranges reveals that the conductor kinetic inductance creates an ultra-broadband linear-dispersion and constant-attenuation region in the THz regime. This so-called LC region is an ideal characteristic that is known to be absent in macro-scale transmission lines. The kinetic-LC frequency range is dictated by the structural dimensionality and the free-carrier scattering rate of the conductor material. Moreover, up to 40x wavelength reduction is observed in graphene transmission lines. PMID:27137628

  2. Development of an accurate transmission line fault locator using the global positioning system satellites

    NASA Technical Reports Server (NTRS)

    Lee, Harry

    1994-01-01

    A highly accurate transmission line fault locator based on the traveling-wave principle was developed and successfully operated within B.C. Hydro. A transmission line fault produces a fast-risetime traveling wave at the fault point which propagates along the transmission line. This fault locator system consists of traveling wave detectors located at key substations which detect and time tag the leading edge of the fault-generated traveling wave as if passes through. A master station gathers the time-tagged information from the remote detectors and determines the location of the fault. Precise time is a key element to the success of this system. This fault locator system derives its timing from the Global Positioning System (GPS) satellites. System tests confirmed the accuracy of locating faults to within the design objective of +/-300 meters.

  3. A test of a 2 Tesla superconducting transmission line magnet system

    SciTech Connect

    Piekarz, Henryk; Carcagno, Ruben; Claypool, Brad; Foster, George W.; Hays, Steven L.; Huang, Yuenian; Kashikhin, Vladimir; Malamud, Ernest; Mazur, Peter O.; Nehring, Roger; Oleck, Andrew; Rabehl, Roger; Schlabach, Phil; Sylvester, Cosmore; Velev, Gueorgui; Volk, James; Wake, Masayoshi; /KEK, Tsukuba

    2005-09-01

    Superconducting transmission line magnet test system for an injector accelerator of a staged VLHC proton-proton colliding beam accelerator has been built and operated at Fermilab. The 1.5 m long, twin-aperture, combined function dipole magnet of 2 Tesla field is excited by a single turn 100 kA transmission line superconductor. The 100 kA dc current is generated using dc-dc switching converters powered by a bulk 240 kW supply. A pair of horizontally placed conventional leads facilitates transfer of this current to the magnet transmission line superconductor operating at liquid helium temperature. Fabrication of magnet components and magnet assembly work are described. The magnet test system and its operation are presented, and the performance is summarized.

  4. Low-Loss Transmission Lines for High-Power Terahertz Radiation

    PubMed Central

    Nanni, Emilio A.; Jawla, Sudheer K.; Shapiro, Michael A.; Woskov, Paul P.; Temkin, Richard J.

    2012-01-01

    Applications of high-power Terahertz (THz) sources require low-loss transmission lines to minimize loss, prevent overheating and preserve the purity of the transmission mode. Concepts for THz transmission lines are reviewed with special emphasis on overmoded, metallic, corrugated transmission lines. Using the fundamental HE11 mode, these transmission lines have been successfully implemented with very low-loss at high average power levels on plasma heating experiments and THz dynamic nuclear polarization (DNP) nuclear magnetic resonance (NMR) experiments. Loss in these lines occurs directly, due to ohmic loss in the fundamental mode, and indirectly, due to mode conversion into high order modes whose ohmic loss increases as the square of the mode index. An analytic expression is derived for ohmic loss in the modes of a corrugated, metallic waveguide, including loss on both the waveguide inner surfaces and grooves. Simulations of loss with the numerical code HFSS are in good agreement with the analytic expression. Experimental tests were conducted to determine the loss of the HE11 mode in a 19 mm diameter, helically-tapped, three meter long brass waveguide with a design frequency of 330 GHz. The measured loss at 250 GHz was 0.029 ± 0.009 dB/m using a vector network analyzer approach and 0.047 ± 0.01 dB/m using a radiometer. The experimental results are in reasonable agreement with theory. These values of loss, amounting to about 1% or less per meter, are acceptable for the DNP NMR application. Loss in a practical transmission line may be much higher than the loss calculated for the HE11 mode due to mode conversion to higher order modes caused by waveguide imperfections or miter bends. PMID:23162673

  5. Low-loss Transmission Lines for High-power Terahertz Radiation

    NASA Astrophysics Data System (ADS)

    Nanni, Emilio Alessandro; Jawla, Sudheer Kumar; Shapiro, Michael A.; Woskov, Paul P.; Temkin, Richard J.

    2012-07-01

    Applications of high-power Terahertz (THz) sources require low-loss transmission lines to minimize loss, prevent overheating and preserve the purity of the transmission mode. Concepts for THz transmission lines are reviewed with special emphasis on overmoded, metallic, corrugated transmission lines. Using the fundamental HE11 mode, these transmission lines have been successfully implemented with very low-loss at high average power levels on plasma heating experiments and THz dynamic nuclear polarization (DNP) nuclear magnetic resonance (NMR) experiments. Loss in these lines occurs directly, due to ohmic loss in the fundamental mode, and indirectly, due to mode conversion into high order modes whose ohmic loss increases as the square of the mode index. An analytic expression is derived for ohmic loss in the modes of a corrugated, metallic waveguide, including loss on both the waveguide inner surfaces and grooves. Simulations of loss with the numerical code HFSS are in good agreement with the analytic expression. Experimental tests were conducted to determine the loss of the HE11 mode in a 19 mm diameter, helically-tapped, three meter long brass waveguide with a design frequency of 330 GHz. The measured loss at 250 GHz was 0.029 ± 0.009 dB/m using a vector network analyzer approach and 0.047 ± 0.01 dB/m using a radiometer. The experimental results are in reasonable agreement with theory. These values of loss, amounting to about 1% or less per meter, are acceptable for the DNP NMR application. Loss in a practical transmission line may be much higher than the loss calculated for the HE11 mode due to mode conversion to higher order modes caused by waveguide imperfections or miter bends.

  6. Low-Loss Transmission Lines for High-Power Terahertz Radiation.

    PubMed

    Nanni, Emilio A; Jawla, Sudheer K; Shapiro, Michael A; Woskov, Paul P; Temkin, Richard J

    2012-07-01

    Applications of high-power Terahertz (THz) sources require low-loss transmission lines to minimize loss, prevent overheating and preserve the purity of the transmission mode. Concepts for THz transmission lines are reviewed with special emphasis on overmoded, metallic, corrugated transmission lines. Using the fundamental HE(11) mode, these transmission lines have been successfully implemented with very low-loss at high average power levels on plasma heating experiments and THz dynamic nuclear polarization (DNP) nuclear magnetic resonance (NMR) experiments. Loss in these lines occurs directly, due to ohmic loss in the fundamental mode, and indirectly, due to mode conversion into high order modes whose ohmic loss increases as the square of the mode index. An analytic expression is derived for ohmic loss in the modes of a corrugated, metallic waveguide, including loss on both the waveguide inner surfaces and grooves. Simulations of loss with the numerical code HFSS are in good agreement with the analytic expression. Experimental tests were conducted to determine the loss of the HE(11) mode in a 19 mm diameter, helically-tapped, three meter long brass waveguide with a design frequency of 330 GHz. The measured loss at 250 GHz was 0.029 ± 0.009 dB/m using a vector network analyzer approach and 0.047 ± 0.01 dB/m using a radiometer. The experimental results are in reasonable agreement with theory. These values of loss, amounting to about 1% or less per meter, are acceptable for the DNP NMR application. Loss in a practical transmission line may be much higher than the loss calculated for the HE(11) mode due to mode conversion to higher order modes caused by waveguide imperfections or miter bends. PMID:23162673

  7. Simple Correctors for Elimination of High-Order Modes in Corrugated Waveguide Transmission Lines.

    PubMed

    Kowalski, Elizabeth J; Shapiro, Michael A; Temkin, Richard J

    2014-01-01

    When using overmoded corrugated waveguide transmission lines for high power applications, it is necessary to control the mode content of the system. Ideally, overmoded corrugated transmission lines operate in the fundamental HE11 mode and provide low losses for long distances. Unwanted higher order modes (HOMs), particularly LP11 and HE12, are often excited in the experimental systems due to practical misalignments in the transmission line system. This paper discusses how the unwanted modes propagate along with the fundamental mode in the transmission line system by formulating an equation that relates the center of power offset and angle of propagation of a beam (for the HE11 and LP11 modes) or the waist size and phase front radius of curvature of a beam (for the HE11 and HE12 modes). By introducing two miter bend correctors into the transmission system-miter bends that have slightly angled or ellipsoidal mirrors-the HOMs can be precisely manipulated in the system. This technique can be used to eliminate small quantities of unwanted modes, thereby creating a nearly pure fundamental mode beam with minimal losses. Examples of these applications are calculated and show the theoretical conversion of up to 10% HOM content into the fundamental HE11 mode with minimal losses. PMID:25067859

  8. Simple Correctors for Elimination of High-Order Modes in Corrugated Waveguide Transmission Lines

    PubMed Central

    Kowalski, Elizabeth J.; Shapiro, Michael A.; Temkin, Richard J.

    2014-01-01

    When using overmoded corrugated waveguide transmission lines for high power applications, it is necessary to control the mode content of the system. Ideally, overmoded corrugated transmission lines operate in the fundamental HE11 mode and provide low losses for long distances. Unwanted higher order modes (HOMs), particularly LP11 and HE12, are often excited in the experimental systems due to practical misalignments in the transmission line system. This paper discusses how the unwanted modes propagate along with the fundamental mode in the transmission line system by formulating an equation that relates the center of power offset and angle of propagation of a beam (for the HE11 and LP11 modes) or the waist size and phase front radius of curvature of a beam (for the HE11 and HE12 modes). By introducing two miter bend correctors into the transmission system—miter bends that have slightly angled or ellipsoidal mirrors—the HOMs can be precisely manipulated in the system. This technique can be used to eliminate small quantities of unwanted modes, thereby creating a nearly pure fundamental mode beam with minimal losses. Examples of these applications are calculated and show the theoretical conversion of up to 10% HOM content into the fundamental HE11 mode with minimal losses. PMID:25067859

  9. Effect of non-linear capacitance on a non-uniform transmission line

    NASA Astrophysics Data System (ADS)

    Kumar, L.; Shankar Pandey, V.; Parthasarathy, H.; Shrimali, V.; Varshney, G.

    2016-05-01

    In this paper we derive a non-linear polarization electric field relationship in a dielectric by considering harmonics binding of the electrons to its nuclei. We apply this theory to a transmission line to model the non-linear, inhomogeneous frequency-dependent capacitance of the line and approximate an expression for the line current when the line is terminated by load impedance. We then suggest a method for estimating the inhomogeneous, frequency-dependent non-linear component of the line capacitance from the measurements of the far field electromagnetic field radiated by the line current. The far field magnetic vector potential is calculated from the line current by the standard Green's function integration in free space.

  10. Reflection and transmission calculations in a multilayer structure with coherent, incoherent, and partially coherent interference, using the transmission line method.

    PubMed

    Stathopoulos, N A; Savaidis, S P; Botsialas, A; Ioannidis, Z C; Georgiadou, D G; Vasilopoulou, M; Pagiatakis, G

    2015-02-20

    A generalized transmission line method (TLM) that provides reflection and transmission calculations for a multilayer dielectric structure with coherent, partial coherent, and incoherent layers is presented. The method is deployed on two different application fields. The first application of the method concerns the thickness measurement of the individual layers of an organic light-emitting diode. By using a fitting approach between experimental spectral reflectance measurements and the corresponding TLM calculations, it is shown that the thickness of the films can be estimated. The second application of the TLM concerns the calculation of the external quantum efficiency of an organic photovoltaic with partially coherent rough interfaces between the layers. Numerical results regarding the short circuit photocurrent for different layer thicknesses and rough interfaces are provided and the performance impact of the rough interface is discussed in detail. PMID:25968218

  11. Analysis of transmission lines loaded with pairs of coupled resonant elements and application to sensors

    NASA Astrophysics Data System (ADS)

    Naqui, J.; Su, L.; Mata, J.; Martín, F.

    2015-06-01

    This paper is focused on the analysis of transmission lines loaded with pairs of magnetically coupled resonators. We have considered two different structures: (i) a microstrip line loaded with pairs of stepped impedance resonators (SIRs), and (ii) a coplanar waveguide (CPW) transmission line loaded with pairs of split ring resonators (SRRs). In both cases, the line exhibits a single resonance frequency (transmission zero) if the resonators are identical (symmetric structure with regard to the line axis), and this resonance is different to the one of the line loaded with a single resonator due to inter-resonator coupling. If the structures are asymmetric, inter-resonator coupling enhances the distance between the two split resonance frequencies that arise. In spite that the considered lines and loading resonators are very different and are described by different lumped element equivalent circuit models, the phenomenology associated to the effects of coupling is exactly the same, and the resonance frequencies are given by identical expressions. The reported lumped element circuit models of both structures are validated by comparing the circuit simulations with extracted parameters with both electromagnetic simulations and experimental data. These structures can be useful for the implementation of microwave sensors based on symmetry properties.

  12. Design Considerations of Fast-cycling Synchrotrons Based on Superconducting Transmission Line Magnets

    SciTech Connect

    Piekarz, H.; Hays, S.; Huang, Y.; Shiltsev, V.; /Fermilab

    2008-06-01

    Fast-cycling synchrotrons are key instruments for accelerator based nuclear and high-energy physics programs. We explore a possibility to construct fast-cycling synchrotrons by using super-ferric, {approx}2 Tesla B-field dipole magnets powered with a superconducting transmission line. We outline both the low temperature (LTS) and the high temperature (HTS) superconductor design options and consider dynamic power losses for an accelerator with operation cycle of 0.5 Hz. We also briefly outline possible power supply system for such accelerator, and discuss the quench protection system for the magnet string powered by a transmission line conductor.

  13. Mesoscopic Electrical Transmission Line in the Charge-Anticharge Framework:. Spectral Properties and Casimir Forces

    NASA Astrophysics Data System (ADS)

    Flores, J. C.

    In the charge-anticharge framework, we solve explicitly the nonlinear quantum evolution equation for the charge operator of the direct transmission line with discrete charge. The associated spectrum is completely consistent with the well-known limit of continuous charge. In the zero point charge fluctuations state, the attraction between plates is compared with the corresponding Casimir force (related to field fluctuations) which, now, could be interpreted in terms of virtual charge fluctuations. The spectrum of the dual transmission line (left-handed) is also found. Some aspects related to quantum dots (coulomb blockade), structure fine constant and thermodynamics properties are also touched upon.

  14. A method for modeling discontinuities in a microwave coaxial transmission line

    NASA Technical Reports Server (NTRS)

    Otoshi, T. Y.

    1992-01-01

    A method for modeling discontinuities in a coaxial transmission line is presented. The methodology involves the use of a nonlinear least-squares fit program to optimize the fit between theoretical data (from the model) and experimental data. When this method was applied to modeling discontinuities in a slightly damaged Galileo spacecraft S-band (2.295-GHz) antenna cable, excellent agreement between theory and experiment was obtained over a frequency range of 1.70-2.85 GHz. The same technique can be applied for diagnostics and locating unknown discontinuities in other types of microwave transmission lines, such as rectangular, circular, and beam waveguides.

  15. Power market analysis and potential revenues of new transmission lines in a deregulated environment.

    SciTech Connect

    Koritarov, V. S.; Veselka, T. D.; Trouille, B.

    2002-05-15

    This paper describes an approach that was developed to analyze the market potential for power transactions via proposed transmission lines among the electric power utilities of Macedonia, Bulgaria, and Albania. The approach uses an integrated modeling framework consisting of several computer models that estimate the financial and economic benefits of constructing new transmission lines. The integrated model simulates open power markets under several scenarios that include cases with and without the proposed interconnections. The approach estimates power transactions among the three Balkan utility systems and the benefits of coordinated or joint system operations, including short-term power sales agreements.

  16. Transmission line component testing for the ITER Ion Cyclotron Heating and Current Drive System

    NASA Astrophysics Data System (ADS)

    Goulding, Richard; Bell, G. L.; Deibele, C. E.; McCarthy, M. P.; Rasmussen, D. A.; Swain, D. W.; Barber, G. C.; Barbier, C. N.; Cambell, I. H.; Moon, R. L.; Pesavento, P. V.; Fredd, E.; Greenough, N.; Kung, C.

    2014-10-01

    High power RF testing is underway to evaluate transmission line components for the ITER Ion Cyclotron Heating and Current Drive System. The transmission line has a characteristic impedance Z0 = 50 Ω and a nominal outer diameter of 305 mm. It is specified to carry up to 6 MW at VSWR = 1.5 for 3600 s pulses, with transient voltages up to 40 kV. The transmission line is actively cooled, with turbulent gas flow (N2) used to transfer heat from the inner to outer conductor, which is water cooled. High voltage and high current testing of components has been performed using resonant lines generating steady state voltages of 35 kV and transient voltages up to 60 kV. A resonant ring, which has operated with circulating power of 6 MW for 1 hr pulses, is being used to test high power, low VSWR operation. Components tested to date include gas barriers, straight sections of various lengths, and 90 degree elbows. Designs tested include gas barriers fabricated from quartz and aluminum nitride, and transmission lines with quartz and alumina inner conductor supports. The latest results will be presented. This manuscript has been authored by UT-Battelle, LLC, under Contract No. DE-AC05-00OR22725 with the U.S. Department of Energy.

  17. Investigation of effects of 60-Hz electric and magnetic fields on operant and social behavior and on the neuroendocrine system of nonhuman primates. Social behavior portions of Experiments III and IV: Quarterly report No. 39

    SciTech Connect

    Rogers, W.R.; Rhodes, J.W.

    1992-09-01

    A cohort of sixteen male baboons were assigned to electric and magnetic field (E/MF) exposure and sham-exposure. The social behavior subjects were simultaneously exposed to 60 Hz E/MF. Ten behavioral categories were measured. Each behavioral category was comprised of multiple molecular behaviors that could be objectively identified and counted. Six of the behavior categories were ``social``, in that interactions between subjected were involved. The remaining four were ``non-social`` and pertained to individual behaviors such as movements or postural stances.

  18. Weld-Windsor 115-kV Transmission Line Project, Weld County, Colorado

    SciTech Connect

    1996-05-01

    The Western Area Power Administration is proposing to rebuild a 3.0 mile segment of the existing Flatiron-Weld 115-kV transmission line in Weld County. The line would be reconductored with new conductor on new wood pole double circuit structures. The new structures would support a double circuit transmission line configuration. The first circuit would be owned by Western and the second by Public Service Company of Colorado (PSCO). Alternatives considered included no action, constructing PSCO`s circuit on new right-of-way, and reconductoring Western`s existing line on the same structures. The proposed action was selected because it provided an opportunity to share structures with PSCO and, overall, would minimize costs and environmental impacts. The environmental assessment identifies minor effects on existing natural or human resources and minor benefits for agricultural operations.

  19. Exact Solutions and Bifurcations of a Modulated Equation in a Discrete Nonlinear Electrical Transmission Line (III)

    NASA Astrophysics Data System (ADS)

    Li, Jibin; Chen, Fengjuan

    In this paper, we consider a modulated equation in a discrete nonlinear electrical transmission line. This model is an integrable planar dynamical system having three singular straight lines. By using the theory of singular systems to investigate the dynamical behavior for this system, we obtain bifurcations of phase portraits under different parameter conditions. Corresponding to some special level curves, we derive exact explicit parametric representations of solutions (including smooth solitary wave solutions, peakons, compactons, periodic cusp wave solutions) under different parameter conditions.

  20. Series-capacitor compensated shield scheme for enhanced mitigation of transmission line magnetic fields

    SciTech Connect

    Walling, R.A.; Paserba, J.J. ); Burns, C.W. )

    1993-01-01

    This paper presents a new magnetic field mitigation concept involving a series-compensated shield circuit paralleling a transmission line between the line and the right-of-way edge. An evaluation methodology is proposed which is valid for analyzing magnetic field mitigation concepts in general. The research discussed in this paper identifies the shield circuit and compensation requirements and shows the effectiveness of the scheme. Practical implementation considerations are included.

  1. Electrical and mechanical design criteria for EHV and UHV: overhead transmission lines

    SciTech Connect

    Not Available

    1980-06-01

    The results are presented of a program devoted to the selection of electrical and mechanical design criteria and parameters for overhead power transmission lines for ac systems rated at from 345 to 1100 kV and for dc systems rated at from 600 to 1200 kV. Information is included on the environmental effects, i.e., audible noise and electric fields, of the lines, mechanical and economic requirements, safety, failures, grounding, and lightning protection. (LCL)

  2. Grand Coulee - Bell 500-kV Transmission Line Project, Draft Environmental Impact Statement

    SciTech Connect

    N /A

    2002-08-09

    BPA is proposing to construct a 500-kilovolt (kV) transmission line that would extend approximately 84 miles between the Grand Coulee 500-kV Switchyard, near Grand Coulee Dam, and the Bell Substation, in Mead just north of Spokane. The new line would cross portions of Douglas, Grant, Lincoln, and Spokane counties. In addition to the transmission line, new equipment would be installed at the substations at each end of the new line and at other facilities. The proposed action would remove an existing 115-kV transmission line and replace it with the new 500-kV line on existing right-of-way for most of its length. Additional right-of-way would be needed in the first 3.5 miles out of the Grand Coulee Switchyard to connect to the existing 115-kV right-of-way. Since the mid-1990s, the transmission path west of Spokane, called the West of Hatwai transmission pathway, has grown increasingly constrained. To date, BPA has been able to manage operation of the path through available operating practices, and customer needed have been met while maintaining the reliability of the path. however, in early 2001, operations showed that the amount of electricity that needs to flow from east to west along this path creates severe transmission congestion. Under these conditions, the system is at risk of overloads and violation of industry safety and reliability standards. The problem is particularly acute in the spring and summer months because of the large amount of power generated by dams east of the path. Large amounts of water cannot be spilled during that time in order for BPA to fulfill its obligation to protect threatened and endangered fish. The amount of power that needs to move through this area during these months at times could exceed the carrying capacity of the existing transmission lines. In additional capacity is not added, BPA will run a significant risk that it will not be able to continue to meet its contractual obligations to deliver power and maintain reliability

  3. Large-scale MOSFET and interconnect circuit simulation using waveform relaxation and transmission line time step control

    NASA Astrophysics Data System (ADS)

    Chen, Chun-Jung; Chang, Allen Y.; Tsai, Chang-Lung; Lee, Chih-Jen; Chou, Li-Ping; Shin, Tien-Hao

    2012-04-01

    A modified Waveform Relaxation algorithm with transmission line calculation ability is proposed to perform large-scale circuit simulation for MOSFET circuits with lossy coupled transmission lines. The adopted full time-domain transmission line calculation algorithm, based on the Method of Characteristic, has been equipped with a time step control scheme to improve the calculation efficiency. All proposed methods have been implemented in a simulation program to simulate several circuits. The simulation results well justify the success of proposed methods.

  4. Canby Area Service Project substation and associated transmission line. Environmental Assessment

    SciTech Connect

    Not Available

    1992-02-01

    Bonneville Power Administration (BPA) provides power to Surprise Valley Electrification Corporation (SVEC) in Modoc County, California. BPA uses PacificCorp`s substation and transmission facilities between Alturas and Canby, California to transfer power to SVEC`s Canby Substation. In the next year, SVEC expects increased industrial, agricultural, and residential electric loads on their 69-kV transmission system south of Canby. SVEC`s substation can accommodate only about 10 percent of the expected additional electric load. BPA`s proposed action is intended to meet SVEC`s increasing electric load. BPA proposes to meet SVEC`s increasing energy load by tapping into BPA`s existing BPA Malin-Warner 230-kV transmission line, and building an 7.9-mile transmission line to a new BPA substation. BPA proposes to build the new substation next to the west side of SVEC`s Canby Substation (Figure 1). This new substation will allow SVEC to move the additional power over their existing transmission or distribution lines. This report is the environmental assessment of the potential impact of the proposed project. The assessment determined that no ``environmental impact statement`` is not required.

  5. Canby Area Service Project : Substation and Associated Transmission Line : Environmental Assessment.

    SciTech Connect

    United States. Bonneville Power Administration.

    1992-02-01

    Bonneville Power Administration (BPA) provides power to Surprise Valley Electrification Corporation (SVEC) in Modoc County, California. BPA uses PacificCorp's substation and transmission facilities between Alturas and Canby, California to transfer power to SVEC's Canby Substation. In the next year, SVEC expects increased industrial, agricultural, and residential electric loads on their 69-kV transmission system south of Canby. SVEC's substation can accommodate only about 10 percent of the expected additional electric load. BPA's proposed action is intended to meet SVEC's increasing electric load. BPA proposes to meet SVEC's increasing energy load by tapping into BPA's existing BPA Malin-Warner 230-kV transmission line, and building an 7.9-mile transmission line to a new BPA substation. BPA proposes to build the new substation next to the west side of SVEC's Canby Substation (Figure 1). This new substation will allow SVEC to move the additional power over their existing transmission or distribution lines. This report is the environmental assessment of the potential impact of the proposed project. The assessment determined that no environmental impact statement'' is not required.

  6. On-chip sub-terahertz surface plasmon polariton transmission lines in CMOS

    PubMed Central

    Liang, Yuan; Yu, Hao; Zhang, Hao Chi; Yang, Chang; Cui, Tie Jun

    2015-01-01

    A low-loss and low-crosstalk surface-wave transmission line (T-line) is demonstrated at sub-THz in CMOS. By introducing periodical sub-wavelength structures onto the metal transmission line, surface plasmon polaritons (SPP) are excited and propagate signals via a strongly localized surface wave. Two coupled SPP T-lines and two quasi-TEM T-lines are both fabricated on-chip, each with a separation distance of 2.4 μm using standard 65 nm CMOS technology. Measurement results show that the SPP T-lines achieve wideband reflection coefficient lower than −14 dB and crosstalk ratio better than −24 dB, which is 19 dB lower on average than the traditional T-lines from 220 GHz to 325 GHz. The demonstrated compact and wideband SPP T-lines have shown great potential for future realization of highly dense on-chip sub-THz communications in CMOS. PMID:26445889

  7. Sound Transmission Through Multi-Panel Structures Lined with Elastic Porous Materials

    NASA Astrophysics Data System (ADS)

    Bolton, J. S.; Shiau, N.-M.; Kang, Y. J.

    1996-04-01

    Theory and measurements related to sound transmission through double panels lined with elastic porous media are presented. The information has application to the design of noise control barriers and to the optimization of aircraft fuselage transmission loss, for example. The major difference between the work described here and earlier research in this field relates to the treatment of the porous material that is used to line the cavity between the two panels of the double panel structure. Here we have used the porous material theory proposed by Biot since it takes explicit account of all the wave types known to propagate in elastic porous materials. As a result, it is possible to use the theory presented here to calculate the transmission loss of lined double panels at arbitrary angles of incidence; results calculated over a range of incidence angles may then be combined to yield the random incidence transmission loss. In this paper, the equations governing wave propagation in an elastic porous material are first considered briefly and then the general forms for the stresses and displacements within the porous material are given. Those solutions are expressed in terms of a number of constants that can be determined by application of appropriate boundary conditions. The boundary conditions required to model double panels having linings that are either directly attached to the facing panels or separated?!from them by air gaps are presented and discussed. Measurements of the random incidence transmission loss of aluminium double-panel structures lined with polyurethane foam are presented and have been found to be in good agreement with theoretical predictions. Both the theoretical predictions and the measured results have shown that the method by which an elastic porous lining material is attached to the facing panels can have a profound influence on the transmission loss of the panel system. It has been found, for example, that treatments in which the lining material

  8. 49 CFR 192.717 - Transmission lines: Permanent field repair of leaks.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Transmission lines: Permanent field repair of leaks. 192.717 Section 192.717 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) PIPELINE SAFETY TRANSPORTATION OF NATURAL AND...

  9. Conversion from constitutive parameters to dispersive transmission line parameters for multi-band metamaterials

    NASA Astrophysics Data System (ADS)

    Ozturk, Yusuf; Egemen Yilmaz, Asim; Ozbay, Ekmel

    2016-04-01

    In this study, we explain an approach including conversion from constitutive parameters to dispersive transmission line parameters using the double-band DNG (double-negative) properties of the circular type fishnet metamaterials. After designing the metamaterial structure, the numerical calculations and the composite right/left-handed (CRLH) modeling of circular-type metamaterials are realized in free space. Detailed dispersion characteristics give us the opportunity to explain the true behavior of the inclusions during the analysis stage. By combining the results coming from the standard retrieval procedure with the conventional CRLH theory, we calculate the actual values of the transmission line parameters for all frequency regimes. The constitutive parameters of an equivalent CRLH transmission line are derived and shown to be negative values. It is shown that the constitutive parameters present the same behavior for all negative refractive index regimes. The double-negative properties and the phase advance/lag behavior of metamaterials are observed based on the dispersive transmission line parameters.

  10. 76 FR 19698 - Safety Zone; Repair of High Voltage Transmission Lines to Logan International Airport, Saugus...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-08

    ... Logan International Airport, Saugus River, Saugus, Massachusetts, in the Federal Register (76 FR 4575... repairs. National Grid, the transmission line repair company has not specified the exact date repairs will... Logan International Airport, Saugus River, Saugus, Massachusetts, in the Federal Register (76 FR...

  11. 7 CFR 1726.76 - Substation and transmission line materials and equipment.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... RUS Form 198, Equipment Contract, or a written purchase order for purchases of equipment of less than... transmission line material or equipment of the types listed in accordance with the provisions of part 1728 of... procurement method that best meets its needs for purchase of material and equipment to be used in...

  12. 7 CFR 1726.76 - Substation and transmission line materials and equipment.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... RUS Form 198, Equipment Contract, or a written purchase order for purchases of equipment of less than... transmission line material or equipment of the types listed in accordance with the provisions of part 1728 of... procurement method that best meets its needs for purchase of material and equipment to be used in...

  13. 7 CFR 1726.76 - Substation and transmission line materials and equipment.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... RUS Form 198, Equipment Contract, or a written purchase order for purchases of equipment of less than... transmission line material or equipment of the types listed in accordance with the provisions of part 1728 of... procurement method that best meets its needs for purchase of material and equipment to be used in...

  14. 7 CFR 1726.76 - Substation and transmission line materials and equipment.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... RUS Form 198, Equipment Contract, or a written purchase order for purchases of equipment of less than... transmission line material or equipment of the types listed in accordance with the provisions of part 1728 of... procurement method that best meets its needs for purchase of material and equipment to be used in...

  15. 7 CFR 1726.76 - Substation and transmission line materials and equipment.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... RUS Form 198, Equipment Contract, or a written purchase order for purchases of equipment of less than... transmission line material or equipment of the types listed in accordance with the provisions of part 1728 of... procurement method that best meets its needs for purchase of material and equipment to be used in...

  16. 76 FR 4575 - Safety Zone; Repair of High Voltage Transmission Lines to Logan International Airport, Saugus...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-26

    ..., 2008, issue of the Federal Register (73 FR 3316). ] Public Meeting We do not now plan to hold a public... to Logan International Airport, Saugus River, Saugus, MA AGENCY: Coast Guard, DHS. ACTION: Notice of... of high voltage transmission lines to Logan Airport. This safety zone is required to provide for...

  17. 49 CFR 236.73 - Open-wire transmission line; clearance to other circuits.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Open-wire transmission line; clearance to other circuits. 236.73 Section 236.73 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RULES, STANDARDS, AND INSTRUCTIONS GOVERNING THE INSTALLATION, INSPECTION,...

  18. Position-momentum-entangled photon pairs in nonlinear waveguides and transmission lines

    NASA Astrophysics Data System (ADS)

    Sherkunov, Y.; Whittaker, David M.; Fal'ko, Vladimir

    2016-04-01

    We analyze the correlation properties of light in nonlinear waveguides and transmission lines, predict the position-momentum realization of the Einstein-Podolsky-Rosen paradox for photon pairs in Kerr-type nonlinear photonic circuits, and we show how two-photon entangled states can be generated and detected.

  19. 76 FR 15970 - Central Ferry to Lower Monumental 500-kilovolt Transmission Line Project

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-22

    ... AGENCY: Bonneville Power Administration (BPA), Department of Energy (DOE). ACTION: Notice of Availability..., and Walla Walla counties, Washington. BPA has decided to implement the Combination A Alternative... single- circuit transmission line from BPA's new Central Ferry Substation near the Port of Central...

  20. 78 FR 76140 - Extension of Public Comment Period for the Champlain Hudson Power Express Transmission Line...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-16

    ...The U.S. Department of Energy (DOE) is extending the public comment period for the Champlain Hudson Power Express Transmission Line Project Draft Environmental Impact Statement (DOE/EIS-0447). The Draft EIS evaluates the environmental impacts of DOE's proposed Federal action of issuing a Presidential permit to the Applicant, Champlain Hudson Power Express, Inc. (CHPEI), to construct, operate,......

  1. Multiwavelet packet entropy and its application in transmission line fault recognition and classification.

    PubMed

    Liu, Zhigang; Han, Zhiwei; Zhang, Yang; Zhang, Qiaoge

    2014-11-01

    Multiwavelets possess better properties than traditional wavelets. Multiwavelet packet transformation has more high-frequency information. Spectral entropy can be applied as an analysis index to the complexity or uncertainty of a signal. This paper tries to define four multiwavelet packet entropies to extract the features of different transmission line faults, and uses a radial basis function (RBF) neural network to recognize and classify 10 fault types of power transmission lines. First, the preprocessing and postprocessing problems of multiwavelets are presented. Shannon entropy and Tsallis entropy are introduced, and their difference is discussed. Second, multiwavelet packet energy entropy, time entropy, Shannon singular entropy, and Tsallis singular entropy are defined as the feature extraction methods of transmission line fault signals. Third, the plan of transmission line fault recognition using multiwavelet packet entropies and an RBF neural network is proposed. Finally, the experimental results show that the plan with the four multiwavelet packet energy entropies defined in this paper achieves better performance in fault recognition. The performance with SA4 (symmetric antisymmetric) multiwavelet packet Tsallis singular entropy is the best among the combinations of different multiwavelet packets and the four multiwavelet packet entropies. PMID:25330427

  2. Determination of complex permittivity from propagation constant measurement with planar transmission lines

    Technology Transfer Automated Retrieval System (TEKTRAN)

    A new two-standard calibration procedure is outlined for determining the complex permittivity of materials from the propagation constant measured with planar transmission lines. Once calibrated, a closed-form expression for the material permittivity is obtained. The effects of radiation and conducto...

  3. Measuring the complex permittivity tensor of uniaxial biological materials with coplanar waveguide transmission line

    Technology Transfer Automated Retrieval System (TEKTRAN)

    A simple and accurate technique is described for measuring the uniaxial permittivity tensor of biological materials with a coplanar waveguide transmission-line configuration. Permittivity tensor results are presented for several chicken and beef fresh meat samples at 2.45 GHz....

  4. Synchrophasors-Assisted IPII-Based Intelligent Relaying for Transmission Lines Including UPFC

    NASA Astrophysics Data System (ADS)

    Jena, Manas Kumar; Samantaray, S. R.

    2015-02-01

    This paper proposes a synchrophasors-assisted intelligent relaying scheme for transmission lines compensated by Unified Power Flow Controller (UPFC). The algorithm uses a new relaying signal termed as imaginary part of integrated impedance (IPII). The synchronized phasor measurements at both ends of the transmission line are used to extract voltage and current phasors from instantaneous voltage and current signals. The voltage and current phasors are utilized to derive IPII of each phase. Further, IPII of each phase is used as input to a data-mining model termed as decision tree (DT) which provides the final relaying decision. The proposed algorithm is validated on real-time digital simulator (RTDS) platform, and the results obtained indicate that the proposed scheme is both dependable and secure in protecting transmission system compensated by UPFC.

  5. Fuzzy-Wavelet Based Double Line Transmission System Protection Scheme in the Presence of SVC

    NASA Astrophysics Data System (ADS)

    Goli, Ravikumar; Shaik, Abdul Gafoor; Tulasi Ram, Sankara S.

    2014-07-01

    Increasing the power transfer capability and efficient utilization of available transmission lines, improving the power system controllability and stability, power oscillation damping and voltage compensation have made strides and created Flexible AC Transmission (FACTS) devices in recent decades. Shunt FACTS devices can have adverse effects on distance protection both in steady state and transient periods. Severe under reaching is the most important problem of relay which is caused by current injection at the point of connection to the system. Current absorption of compensator leads to overreach of relay. This work presents an efficient method based on wavelet transforms, fault detection, classification and location using Fuzzy logic technique which is almost independent of fault impedance, fault distance and fault inception angle. The proposed protection scheme is found to be fast, reliable and accurate for various types of faults on transmission lines with and without Static Var compensator at different locations and with various incidence angles.

  6. Identification and characterization of populations living near high-voltage transmission lines: a pilot study.

    PubMed Central

    Wartenberg, D; Greenberg, M; Lathrop, R

    1993-01-01

    Populations living close to high-voltage transmission lines often have residential magnetic field exposures in excess of 1 microT, and sometimes over 2 microT. Yet, populations studied in most epidemiologic investigations of the association between residential magnetic field exposure and cancer typically have exposures below 1 microT and frequently below 0.5 microT. To improve statistical power and precision, it would be useful to compare high exposure populations with low exposure populations rather than only studying small differences within low exposure populations. Toward this end, we have developed an automated method for identifying populations living near high-voltage transmission lines. These populations likely have more highly exposed individuals than the population at large. The method uses a geographic information system (GIS) to superimpose digitized transmission line locations on U.S. Census block location data and then extract relevant demographic data. Analysis of data from a pilot study of the populations residing within 100 m of a 29-km segment of one 230-kV line in New Jersey shows that when compared to populations in the surrounding census blocks farther than 100 m from this line, those populations close to the line have similar demographics but differ in terms of perceived housing value variables. We believe that the approach we have developed will enable investigators to rapidly identify and characterize populations living near high-voltage transmission lines on a statewide basis for considering the impact of exposures and for public policy and that these populations also can be used for epidemiologic study. Images p626-a Figure 1. Figure 2. Figure 3. PMID:8143596

  7. Construction of 8000A class 275kV gas insulated transmission line

    SciTech Connect

    Kuroyanagi, Y.; Toya, A. ); Hayashi, T. ); Araki, T. )

    1990-01-01

    The 8000A class 275kV gas insulated transmission lines (GIL), 138m and 158m long, completed as getaway lines in the Shin Noda substation in 1988 is described. The GIL was designed to match large current capacity. New techniques were applied to construct these lines. Thermal expansion and contraction of a straight section of GIL is absorbed by an angle variation of a deflection unit. Supports were designed to absorb a ground depression. Units of GIL were installed with gantry cranes. Joints of enclosure were welded by an automatic welding machine.

  8. Sidney-North Yuma 230-kV Transmission Line Project, Colorado and Nebraska

    SciTech Connect

    Not Available

    1991-06-01

    This report describes the need for a 230-kV overhead transmission line to supply power from Sidney, Nebraska to eastern Colorado. The alternative scenario compared to construction of the line is No Action. Rejected alternatives include underground lines and different routing paths, with a possible extension to the Sterling area. Both scenarios are evaluated for environmental effects, cost, and consequences for the eastern Colorado region. The proposed route is determined to be the environmentally preferred choice. 120 refs., 6 figs., 13 tabs. (MHB)

  9. Theory and simulation of high-power microwave generation in a magnetically insulated transmission line oscillator

    NASA Astrophysics Data System (ADS)

    Lemke, Raymond W.; Clark, Collins M.

    1987-10-01

    The magnetically insulated transmission line (MITE-LINE) oscillator is an electron beam diode comprised of a field emitting cathode and a corrugated anode. The device is similar to a linear magnetron except that the insulating magnetic field is self-generated. The self-insulating property makes this device a robust high-power microwave tube. Using the thin-beam approximation a dispersion relation for a cylindrical MITE-LINE oscillator is derived. The dispersion relation is used to predict frequency and growth rate of the microwave generating instability. Analytical results are compared with CCUBE particle simulations.

  10. Theory and simulation of high-power microwave generation in a magnetically insulated transmission line oscillator

    SciTech Connect

    Lemke, R.W.; Collins Clark, M.

    1987-10-15

    The magnetically insulated transmission line (MITE-LINE) oscillator is an electron beam diode comprised of a field emitting cathode and a corrugated anode. The device is similar to a linear magnetron except that the insulating magnetic field is self-generated. The self-insulating property makes this device a robust high-power microwave tube. Using the thin-beam approximation we have derived a dispersion relation for a cylindrical MITE-LINE oscillator. The dispersion relation is used to predict frequency and growth rate of the microwave generating instability. Analytical results are compared with c-smcapsc-smcapsu-smcapsb-smcapse-smcaps particle simulations.

  11. Transient voltages in a tranformer connected to a 500 kV transmission line

    SciTech Connect

    Indulkar, C.S.; Kothari, D.P.; Saha, S.N.

    1985-09-01

    The objective of the study described in this paper was to formulate a simple way of calculating the distribution of transient voltages at different points of a cascaded system consisting of a transformer winding connected to a transmission line. A method of calculating the steady-state voltage distribution based on a simple eigenvalue technique for the analysis of identical ladder networks representing the line and the transformer winding is described which is then used in conjunction with the numerical inversion of the Fourier integral to obtain the transient voltage waveforms at various points in a 500 kV line and in the transformer winding.

  12. Multivariable time series prediction for the icing process on overhead power transmission line.

    PubMed

    Li, Peng; Zhao, Na; Zhou, Donghua; Cao, Min; Li, Jingjie; Shi, Xinling

    2014-01-01

    The design of monitoring and predictive alarm systems is necessary for successful overhead power transmission line icing. Given the characteristics of complexity, nonlinearity, and fitfulness in the line icing process, a model based on a multivariable time series is presented here to predict the icing load of a transmission line. In this model, the time effects of micrometeorology parameters for the icing process have been analyzed. The phase-space reconstruction theory and machine learning method were then applied to establish the prediction model, which fully utilized the history of multivariable time series data in local monitoring systems to represent the mapping relationship between icing load and micrometeorology factors. Relevant to the characteristic of fitfulness in line icing, the simulations were carried out during the same icing process or different process to test the model's prediction precision and robustness. According to the simulation results for the Tao-Luo-Xiong Transmission Line, this model demonstrates a good accuracy of prediction in different process, if the prediction length is less than two hours, and would be helpful for power grid departments when deciding to take action in advance to address potential icing disasters. PMID:25136653

  13. Data-Mining-Based Intelligent Differential Relaying for Transmission Lines Including UPFC and Wind Farms.

    PubMed

    Jena, Manas Kumar; Samantaray, Subhransu Ranjan

    2016-01-01

    This paper presents a data-mining-based intelligent differential relaying scheme for transmission lines, including flexible ac transmission system device, such as unified power flow controller (UPFC) and wind farms. Initially, the current and voltage signals are processed through extended Kalman filter phasor measurement unit for phasor estimation, and 21 potential features are computed at both ends of the line. Once the features are extracted at both ends, the corresponding differential features are derived. These differential features are fed to a data-mining model known as decision tree (DT) to provide the final relaying decision. The proposed technique has been extensively tested for single-circuit transmission line, including UPFC and wind farms with in-feed, double-circuit line with UPFC on one line and wind farm as one of the substations with wide variations in operating parameters. The test results obtained from simulation as well as in real-time digital simulator testing indicate that the DT-based intelligent differential relaying scheme is highly reliable and accurate with a response time of 2.25 cycles from the fault inception. PMID:25807570

  14. Multivariable Time Series Prediction for the Icing Process on Overhead Power Transmission Line

    PubMed Central

    Li, Peng; Zhao, Na; Zhou, Donghua; Cao, Min; Li, Jingjie; Shi, Xinling

    2014-01-01

    The design of monitoring and predictive alarm systems is necessary for successful overhead power transmission line icing. Given the characteristics of complexity, nonlinearity, and fitfulness in the line icing process, a model based on a multivariable time series is presented here to predict the icing load of a transmission line. In this model, the time effects of micrometeorology parameters for the icing process have been analyzed. The phase-space reconstruction theory and machine learning method were then applied to establish the prediction model, which fully utilized the history of multivariable time series data in local monitoring systems to represent the mapping relationship between icing load and micrometeorology factors. Relevant to the characteristic of fitfulness in line icing, the simulations were carried out during the same icing process or different process to test the model's prediction precision and robustness. According to the simulation results for the Tao-Luo-Xiong Transmission Line, this model demonstrates a good accuracy of prediction in different process, if the prediction length is less than two hours, and would be helpful for power grid departments when deciding to take action in advance to address potential icing disasters. PMID:25136653

  15. Broad frequency-band characterizations of electromagnetic energy propagation in planar thin-film transmission lines

    NASA Astrophysics Data System (ADS)

    Kim, Dongchul; Eo, Yungseon

    2014-04-01

    Thin-film transmission lines are experimentally characterized in the frequency range from 10 MHz to 110 GHz. Scattering (S-) parameters for several test lines are measured. Then, two important transmission line parameters ( i.e., the propagation constant and characteristic impedance) are determined in the measured frequency range. The resonances, which are inevitable in a practical experimental environment, are carefully eliminated by de-embedding parasitic effects and by determining the frequency-variant dielectric permittivity based on the Debye model. Based on the experimental work, we showed that the conventional skin-effect model may not be accurate for high-frequencies. Further, the 3-dimensional (3D) numerical field solver does not reflect the radiation loss at high-frequency. Finally, in the millimeter (mm)-wave region, all the three loss mechanisms due to the skin-effect, dielectric polarization, and electromagnetic radiation have to be taken into account.

  16. Simulation of Anti-Galloping Effects of Phase-to-Phase Spacers in Transmission Line

    NASA Astrophysics Data System (ADS)

    Liu, Chao-Qun; Chen, Hua-Ling; Liu, Bin; Liu, Cao-Lan; Sun, Na; Yang, Jia-Lun

    Currently, the application of phase-to-phase spacers can effectively prevent and control line faults caused by conductor galloping and is one of the most effective methods to prevent galloping of transmission lines. The installation layout scheme of phase-to-phase spacers directly affects the anti-galloping effect. Moreover, the common empirical formula can not accurately assess the anti-galloping effect of phase-to-phase spacers. In this paper, the nonlinear finite element method is employed to establish an accurate analysis model of phase-to-phase spacers for conductors. And the anti-galloping effects of phase-to-phase spacers installed in different ways are analyzed, with the aim of providing an effective method for the installation of phase-to-phase spacers used in practical transmission lines.

  17. Efficiency Evaluation of Lightning Fault Inspection in 66kV Transmission Line

    NASA Astrophysics Data System (ADS)

    Narita, Tomomi; Yamaguchi, Setsuo

    Transmission line must be immediately inspected when it was struck by lightning. It is necessary to find and change the damaged part promptly in case the damage is serious. Such case, however, is actually hardly seen due to the fact that the lightning protection system is well designed recently. Therefore, it is important to compare the data of past lightnings and of the transmission line, and make criteria for deciding more precisely in which case the actual inspection should be carried out. The criteria would be as follows: (1) Insulator voltage exceeds critical voltage. (2) Arc current and arc duration exceed characteristic of insulator destruction. (3) Accident phase exceeds 3 line ground fault. (4) Tower foot resistance is up to 10ohm or more. (5) Lightning current is positive characteristic. By using this criteria, the number of lightning fault inspection was reduced by 34%.

  18. Comment on the transmission-line model for computing radiation from lightning

    NASA Technical Reports Server (NTRS)

    Le Vine, D. M.; Willett, J. C.

    1992-01-01

    The 'transmission-line' model is an approximation that is frequently used to relate the electric and magnetic fields radiated during lightning discharges to the currents that produce those fields. A principal prediction of this model is that the distant (radiation) fields are directly proportional to the current propagating along the lightning channel, multiplied by the velocity of propagation. This paper examines the derivation of this relationship and its implications in some detail. It is shown that the formulas commonly used to describe the transmission-line model cannot be correctly applied to many lightning processes. A correction factor is required that is significant when the channel is not oriented perpendicular to the line of sight to the observer, unless the propagation velocity is only a small fraction of the speed of light. An important implication of this more general version of the model is that the current and velocity decouple so that they could be separately determined by suitable, multistation measurements.

  19. Rolled-up transmission line structure for a radiofrequency integrated circuit (RFIC)

    SciTech Connect

    Li, Xiuling; Huang, Wen

    2015-04-28

    A rolled-up transmission line structure for a radiofrequency integrated circuit (RFIC) comprises a multilayer sheet in a rolled configuration comprising multiple turns about a longitudinal axis, where the multilayer sheet comprises a conductive pattern layer on a strain-relieved layer. The conductive pattern layer comprises a first conductive film and a second conductive film separated from the first conductive film in a rolling direction. In the rolled configuration, the first conductive film surrounds the longitudinal axis, and the second conductive film surrounds the first conductive film. The first conductive film serves as a signal line and the second conductive film serves as a conductive shield for the rolled-up transmission line structure.

  20. Design and fabrication of the high-power RF transmission line into the PEFP linac tunnel

    NASA Astrophysics Data System (ADS)

    Seol, Kyung-Tae; Kwon, Hyeok-Jung; Kim, Han-Sung; Cho, Yong-Sub

    2012-07-01

    The 100-MeV proton linear accelerator (linac) for the Proton Engineering Frontier Project (PEFP) has been developed and will be installed at the Gyeong-ju site. For the linac, a total of 11 sets of RF systems are required, and the waveguide layout was fixed to install high-power RF (HPRF) systems. One of the important interfaces with the building construction is the high-power radio-frequency (HPRF) transmission line embedded in the tunnel, which is used to transmit 1-MW RF power to each cavity in the tunnel. The waveguide section penetrating into the linac tunnel was designed with a bending structure for radiation shielding, and the dependence of its voltage standing-wave ratio (VSWR) on the chamfer length of the bending was calculated. The HPRF transmission line was fabricated into a piece of waveguide to prevent moisture and any foreign debris inside the 2.5-m thick concrete block. Air leakage was checked with a pressure of 0.25 psig of nitrogen gas, and a maximum VSWR of 1.196 was obtained by measuring the vector reflection coefficients with the quarter-wave transmission section. In this paper, the design and the fabrication of the HPRF transmission line into the PEFP linac tunnel are presented.

  1. Application of the transmission line method for the study of highly nonlinear multilayer optical structures

    NASA Astrophysics Data System (ADS)

    Moshonas, Nikolaos; Pagiatakis, Gerasimos K.; Papagiannis, Panagiotis; Savaidis, Stylianos P.; Stathopoulos, Nikolaos A.

    2014-11-01

    In this work, we numerically investigate and analyze the properties of an optical structure composed of successive thin film layers that can possess high values of nonlinear susceptibility, affecting the refractive index and/or the absorption coefficient. By applying the transmission line method properly modified to resolve the inclusion of third-order nonlinearity, the spectral reflectivity and transmission of such a device are presented. Specifically, the method is applied to a conceptual design of a distributed Bragg reflector. Optical bistability can be observed, which translates not only to a change in the value of reflectivity as the input power increases, but also to a shift of the Bragg wavelength.

  2. Tucson Electric Power Company Sahuarita-Nogales Transmission Line Draft Environmental Impact Statement

    SciTech Connect

    N /A

    2003-08-27

    Tucson Electric Power Company (TEP) has applied to the U.S. Department of Energy (DOE) for a Presidential Permit to construct and operate a double-circuit, 345,000-volt (345-kV) electric transmission line across the United States border with Mexico. Under Executive Order (EO) 10485 of September 3, 1953, as amended by EO 12038 of February 3, 1978, a Presidential Permit is required to construct, connect, operate, or maintain facilities at the U.S. international border for the transmission of electric energy between the United States and a foreign country. DOE has determined that the issuance of a Presidential Permit to TEP for the proposed project would constitute a major Federal action that may have a significant impact on the environment within the meaning of the ''National Environmental Policy Act of 1969'' (NEPA) 42 United States Code (U.S.C.) {section}4321 et seq. For this reason, DOE has prepared this Draft Environmental Impact Statement (EIS) to evaluate potential environmental impacts from the proposed Federal action (granting a Presidential Permit for the proposed transmission facilities) and reasonable alternatives, including the No Action Alternative. This EIS was prepared in accordance with Section 102(2)(c) of NEPA, Council of Environmental Quality (CEQ) regulations (40 Code of Federal Regulations [CFR] 1500-1508), and DOE NEPA Implementing Procedures (10 CFR 1021). DOE is the lead Federal Agency, as defined by 40 CFR 1501.5. The U.S. Department of Agriculture Forest Service (USFS), the Bureau of Land Management (BLM) of the U.S. Department of the Interior, and the U.S. Section of the International Boundary and Water Commission, U.S. and Mexico (USIBWC), are cooperating agencies. Each of these organizations will use the EIS for its own NEPA purposes, as described in the Federal Agencies' Purpose and Need and Authorizing Actions section of this summary. The 345-kV double-circuit transmission line would consist of twelve transmission line wires, or

  3. Study on galloping behavior of iced eight bundle conductor transmission lines

    NASA Astrophysics Data System (ADS)

    Zhou, Linshu; Yan, Bo; Zhang, Liang; Zhou, Song

    2016-02-01

    Wind tunnel test was carried out to obtain the aerodynamic coefficients of an eight bundle conductor accreted with crescent-shaped ice. A user-defined cable element with torsional degree of freedom is developed in ABAQUS software to capture the torsional deformation of the iced conductors during galloping. By means of the user-defined cable element, different damping ratios in in-plane, out-of-plane and torsional directions of the conductors can be defined and the aerodynamic forces varying with their motion status can be exerted on the conductors conveniently when ABAQUS is used to simulate galloping of transmission lines. A wind tunnel test to model galloping of an iced eight bundle conductor segment was carried out, and the validity of the numerical simulation method is demonstrated by the agreement of the galloping orbit of the bundle conductor segment model recorded in the test and that by the numerical simulation. Furthermore, galloping behavior, including dynamic responses, galloping orbits, frequencies, vibration modes and amplitudes, of typical iced eight bundle conductor transmission lines in the cases of different span lengths, initial tensions in sub-conductors, wind velocities, angles of wind attack and damping ratios is studied, and the galloping behavior of the lines with internal resonance conditions is discussed. The obtained results may provide a fundamental tool for the development of anti-galloping techniques of eight bundle conductor transmission lines.

  4. A Novel Transient Fault Current Sensor Based on the PCB Rogowski Coil for Overhead Transmission Lines.

    PubMed

    Liu, Yadong; Xie, Xiaolei; Hu, Yue; Qian, Yong; Sheng, Gehao; Jiang, Xiuchen

    2016-01-01

    The accurate detection of high-frequency transient fault currents in overhead transmission lines is the basis of malfunction detection and diagnosis. This paper proposes a novel differential winding printed circuit board (PCB) Rogowski coil for the detection of transient fault currents in overhead transmission lines. The interference mechanism of the sensor surrounding the overhead transmission line is analyzed and the guideline for the interference elimination is obtained, and then a differential winding printed circuit board (PCB) Rogowski coil is proposed, where the branch and return line of the PCB coil were designed to be strictly symmetrical by using a joining structure of two semi-rings and collinear twisted pair differential windings in each semi-ring. A serial test is conducted, including the frequency response, linearity, and anti-interference performance as well as a comparison with commercial sensors. Results show that a PCB Rogowski coil has good linearity and resistance to various external magnetic field interferences, thus enabling it to be widely applied in fault-current-collecting devices. PMID:27213402

  5. A Novel Transient Fault Current Sensor Based on the PCB Rogowski Coil for Overhead Transmission Lines

    PubMed Central

    Liu, Yadong; Xie, Xiaolei; Hu, Yue; Qian, Yong; Sheng, Gehao; Jiang, Xiuchen

    2016-01-01

    The accurate detection of high-frequency transient fault currents in overhead transmission lines is the basis of malfunction detection and diagnosis. This paper proposes a novel differential winding printed circuit board (PCB) Rogowski coil for the detection of transient fault currents in overhead transmission lines. The interference mechanism of the sensor surrounding the overhead transmission line is analyzed and the guideline for the interference elimination is obtained, and then a differential winding printed circuit board (PCB) Rogowski coil is proposed, where the branch and return line of the PCB coil were designed to be strictly symmetrical by using a joining structure of two semi-rings and collinear twisted pair differential windings in each semi-ring. A serial test is conducted, including the frequency response, linearity, and anti-interference performance as well as a comparison with commercial sensors. Results show that a PCB Rogowski coil has good linearity and resistance to various external magnetic field interferences, thus enabling it to be widely applied in fault-current-collecting devices. PMID:27213402

  6. TRIFL: A design tool for modeling complex magnetically insulated transmission line geometries

    SciTech Connect

    Mix, L.P.; Mendel, C.W. Jr.; Seidel, D.B.; Rosenthal, S.E.

    1996-12-31

    Vacuum power flow in modern high-power pulsed accelerator transmission lines requires field stresses at the conductors that are so high that negative surfaces become space-charge-limited electron emitters. The performance of these lines can be calculated using two- and three-dimensional, time-dependent, particle-in-cell electromagnetic codes such a TWOQUICK and QUICKSILVER. Extensive design of complex systems using these simulation codes would be extremely expensive and, perhaps, impossible for many of the new pulsed power systems being planned. An analytic model has been developed which predicts the behavior of magnetically insulated transmission lines. The model uses flow impedance parameters with an expanded set of Telegrapher`s equations to calculate radial currents in the transmission lines. This model has been implemented in a code, TRIFL (TRIple-equation-FLow model), on workstations and PC`s and allows one to do detailed designed studies on systems far too complex for similar treatment using a PIC code. TRIFL has been used to design hardware for the PBFA-X accelerator and to analyze PBFA-X data.

  7. 75 FR 33997 - Safety Zone; McNary-John Day Transmission Line Project, Columbia River, Hermiston, OR

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-16

    ... SECURITY Coast Guard 33 CFR Part 165 RIN 1625-AA00 Safety Zone; McNary-John Day Transmission Line Project... zone would subject the public to the hazards associated with the reconstruction of the transmission... transmission towers on the banks of the Columbia River near Hermiston, Oregon between June 10, 2010 and...

  8. 76 FR 19744 - Final Tropic to Hatch 138 kV Transmission Line Project Environmental Impact Statement and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-08

    ... Forest Service Final Tropic to Hatch 138 kV Transmission Line Project Environmental Impact Statement and... Impact Statement (FEIS) for the Tropic to Hatch 138 kV Transmission Line Project and a Proposed... Agency publishes this Notice of Availability in the Federal Register. ADDRESSES: Copies of the Tropic...

  9. Environmental Assessment of the Gering-Stegall 115-kV Transmission Line Consolidation Project, Scotts Bluff County, Nebraska

    SciTech Connect

    1995-05-01

    The Department of Energy (DOE), Western Area Power Administration (Western) proposes to consolidate segments of two transmission lines near the Gering Substation in Gering, Nebraska. The transmission lines are both located in Scotts Bluff County, Nebraska. The transmission lines are both located in Scotts Bluff County, Nebraska, within the city of Gering. Presently, there are three parallel 115-kilovolt (kV) transmission lines on separate rights-of-way (ROW) that terminate at the Gering Substation. The project would include dismantling the Archer-Gering wood-pole transmission line and rebuilding the remaining two lines on single-pole steel double circuit structures. The project would consolidate the Gering-Stegall North and Gering-Stegall South 115-kV transmission lines on to one ROW for a 1.33-mile segment between the Gering Substation and a point west of the Gering Landfill. All existing wood-pole H-frame structures would be removed, and the Gering-Stegall North and South ROWs abandoned. Western is responsible for the design, construction, operation, and maintenance of the line. Western prepared an environmental assessment (EA) that analyzed the potential environmental impacts of the proposed construction, operation, and maintenance of the 115-kV transmission line consolidation. Based on the analyses in the EA, the DOE finds that the proposed action is not a major Federal action significantly affecting the quality of the human environment, within the meaning of the National Environmental Policy Act of 1969 (NEPA).

  10. Effects of 60-Hz electric and magnetic fields on operant and social behavior and on neuroendocrine system of nonhuman primates. Draft final report, October 1, 1988--December 31, 1992

    SciTech Connect

    Rogers, W.R.; Coelho, A.M.; Easley, S.P.; Orr, J.L.; Reiter, R.J.; Rhodes, J.W.

    1992-09-24

    A series of pioneering electric and magnetic field experiments were completed using nonhuman primates and a unique, well-engineered, and reliable exposure facility. Effects of operant behavior, social behavior, and serum melatonin concentration were examined using 60 Hz field combinations of other 6 W/m and 0.6 G or 30 W/m and 1.0 G. Observations noted in the course of this study include: Combines electric and magnetic field exposure does not have any important effect on short-term memory; the transitory increases in social behavior observed in previous electric fields did not occur; combined electric and magnetic field exposure might lead to reduced behavioral frequency in baboon social groups; three experiments clearly establish that one set of exposure conditions does not produce molatonin suppression in nonhuman primates; and a small pilot experiment suggests that a different exposure protocol might result in melatonin suppression.

  11. Investigation of effects of 60-Hz electric and magnetic fields on operant and social behavior and on the neuroendocrine system of nonhuman primates. Quarterly report 37 - Part 2, Appendices

    SciTech Connect

    Rhodes, J.W.

    1992-07-14

    This volume contains detailed experimental data to accompany quarterly report, dated July 14, 1992, by this group entitled ``Investigation of Effects of 60-Hz Electric Fields on Operant and Social Behavior and on the Neuroendocrine System of Nonhuman Primates.`` This volume is a collection of Appendices which are entitled: Appendix A- Field Mapping Data Forms, Appendix B- Exposure Area (East Side) Electric Field Data, Appendix C- Exposure Area (East Side) Magnetic Field Data, Appendix D- Sham Area (West Side) Magnetic Field Data, Appendix E- Memoranda Concerning Field Onset During Experiment IV and the Crossover Experiment, Appendix F- Exposure Area (East Side) Electric Field Data, Appendix G- Exposure Area (East Side) Magnetic Field Data, Appendix H- Sham Area (west Side) Magnetic Field Data, Appendix I- Compiled Data and Anovas for Experiment III Social Data, Appendix J -Written Comments Provided by Statistician Dr. Robert Mason, and Appendix K- Reference Text Provided by Dr. Coelho.

  12. Coupling mid-infrared light from a photonic crystal waveguide to metallic transmission lines

    SciTech Connect

    Blanco-Redondo, Andrea E-mail: r.hillenbrand@nanogune.eu; Garcia-Adeva, Angel; Zubia, Joseba

    2014-01-06

    We propose and theoretically study a hybrid structure consisting of a photonic crystal waveguide (PhC-wg) and a two-wire metallic transmission line (TL), engineered for efficient transfer of mid-infrared (mid-IR) light between them. An efficiency of 32% is obtained for the coupling from the transverse magnetic (TM) photonic mode to the symmetric mode of the TL, with a predicted intensity enhancement factor of 53 at the transmission line surface. The strong coupling is explained by the small phase velocity mismatch and sufficient spatial overlapping between the modes. This hybrid structure could find applications in highly integrated mid-IR photonic-plasmonic devices for biological and gas sensing, among others.

  13. Frequency dependence of the nonlinear response in YBa2Cu3O7-x transmission lines

    NASA Astrophysics Data System (ADS)

    Mateu, Jordi; Booth, James C.; Moeckly, Brian H.

    2007-01-01

    The authors evaluate the frequency dependence of the nonlinear response in high-temperature superconductor YBa2Cu3O7-x thin films by simultaneously measuring the nonlinear intermodulation products and harmonic generation in broadband superconducting transmission lines at 76K. The frequencies of the two-tone incident signal are set to produce spurious signals from 1to21GHz. They extract a nonlinear term ∣ΔR2+jωΔL2∣ by applying a model of spurious signal generation in superconducting transmission lines to their measurement results. They found that this nonlinear term follows a linear dependence on frequency, indicating a dominant contribution of the nonlinear inductance ΔL2 over the nonlinear resistance ΔR2, (ωΔL2≫ΔR2), for the superconducting nonlinear response.

  14. Effect of asphaltene deposition on the internal corrosion in transmission lines

    SciTech Connect

    Morales, J.L.; Viloria, A.; Palacios T, C.A.

    1996-12-31

    Crude oil from Norte de Monagas field, in Venezuela, contains large amounts of asphaltenes, some of them are very unstable with tendency to precipitate. Because liquid is carried over from the separation process in the flow stations, asphaltenes are also present in the gas gathering and transmission lines, precipitating on inner wall of pipelines. The gas gathering and transmission lines contain gas with high partial pressures of CO{sub 2}, some H{sub 2}S and are water saturated; therefore inhibitors are used to control the internal corrosion. There is uncertainty on how inhibitors perform in the presence of asphaltene deposition. To protect the pipelines from external corrosion, cathodic protection is used. Since asphaltenes have polar properties, there exists an uncertainty on whether it enhances asphaltene precipitation and deposition. The purpose of this paper to describe the causes that enhance asphaltene deposition on gas and some of the preliminary result from an ongoing research project carried out by Intevep and Corpoven.

  15. Optical transmission measurements for in-line monitoring of turbid oil-water emulsions

    NASA Astrophysics Data System (ADS)

    Metz, Philipp; Dopf, Katja; Aichholz, Markus; Riedel, Boris; Lemmer, Uli; Freudig, Barbara; Zimmermann, Clifton; Gerken, Martina

    2014-05-01

    For absorbing media the concentration may be calculated directly from the optical transmission following the logarithmic dependence given in the Lambert-Beer law. Due to multiple scattering events in oil-water emulsions (e.g. milk, cream, etc.), these exhibit a nonlinear relationship between the attenuation and the oil concentration. We demonstrate that for increasing oil content in oil-water emulsions the attenuation first increases, then levels out, and finally even decreases for a fat content of 60%. Single-wavelength optical transmission measurements are found to be well suited for the in-line monitoring of oil-water emulsions of fat contents below 20%, e.g., for the in-line fat content monitoring of milk. Using experiments and ray-tracing simulations we evaluate system optimization.

  16. Suppression of the skin effect in radio frequency transmission lines via gridded conductor fibers

    NASA Astrophysics Data System (ADS)

    Williamson, Ian A. D.; Nguyen, Thien-An N.; Wang, Zheng

    2016-02-01

    Microwave propagation in transmission lines is fundamentally limited in bandwidth and reach by the skin and proximity effects. The resultant current crowding imparts a square-root frequency dependence on attenuation, and ultimately limits the spatial resolution of distributed transmission-line sensors and the data rate of communication systems. In this letter, we numerically analyze the microwave attenuation and impedance in μm-scale gridded fiber structures with currents arranged in a checkered pattern. The checkered lattice of currents significantly mitigates both the skin and proximity effects, and exhibits an unprecedented bandwidth (in excess of 1 GHz) of frequency-flat attenuation in a relatively small physical footprint (˜0.01 mm2).

  17. High strength polymer post insulators enable economical transmission lines with low environmental impact

    SciTech Connect

    Burnham, J.T.; Givens, P.S.; Grisham, T.M.

    1994-12-31

    In today`s operational environment, utility transmission engineers are being challenged with a new set of design parameters. In addition to the traditional objective of system reliability, new issues of paramount importance heave evolved. These include the reduction of construction costs, addressing transmission line aesthetics, and optimizing power delivery within restricted right of way. This document describes a design approach which enables the engineer to maximize these criteria without sacrificing system reliability. A laboratory test method for polymer post insulators is also presented which effectively simulates combined mechanical load conditions expected in application, thus allowing the utility engineer to optimize span lengths, conductor size, and insulator selection. Polymer history and benefits associated with compact line design are also reviewed.

  18. Transmission line inversion and synthesis from the point of view of transient response

    NASA Technical Reports Server (NTRS)

    Sondhi, M. M.

    1972-01-01

    The transmission line inversion problem is applied to the speech communication process. The problem involves acquiring information necessary for synthesis of speech and for making models of the speech production mechanism. Formulation for the problem is derived from an analysis of the human vocal tract functions. It is known that speech sounds are produced by acoustic excitation of the tract by means of quasi-periodic pulses from the vocal cords during vowel sounds and turbulent air flow at various points along the tract during fricative sounds. By assuming plane wave propagation, differential equations are obtained relating the cross sectional area of the tract, the pressure, and the volume velocity. By replacing the pressure factor with a voltage factor and the volume velocity by current, the problem becomes a transmission line problem.

  19. Mid-infrared metasurface made of composite right/left-handed transmission-line

    NASA Astrophysics Data System (ADS)

    Luo, Yi; Ying, Xiangxiao; Pu, Yang; Jiang, Yadong; Xu, Jimmy; Liu, Zhijun

    2016-06-01

    We report on the realization of a mid-infrared metasurface based on the concept of composite right/left-handed transmission-line. The metasurface consists of a three-layer metal-insulator-metal structure patterned into transmission-lines by electron-beam lithography. Angle-variable reflection spectroscopy measurements reveal resonant absorption features corresponding to both right- and left-handed propagations in the leaky-wave guided mode region. Material loss is shown to dominate the quality factor of the left-handed modes, while the radiative loss dominates the right-handed ones. The experimental results are in good agreement with full-wave numerical simulations and are explained with an equivalent circuit model.

  20. Asymmetric energy flux in a transmission line based on frequency multiplication.

    PubMed

    Tao, Feng; Chen, Weizhong; Xu, Wen; Pan, Junting; Du, Sidan

    2011-05-01

    We experimentally investigate the energy flux in a nonlinear electrical transmission line formed by two segments which are identical in structure but have different parameters. By consideration of the driving voltage at a frequency within the passband of one segment, the phenomenon of asymmetric energy flux caused by linear waves has been observed. The experiment shows that the possibility of creation of an asymmetric energy flux mainly depends on the nonlinear and lattice effects; namely, the asymmetric energy flux here is carried by a linear wave in the passband, instead of by a nonlinear wave out of the band. To further understand this phenomenon in the transmission line, we study both experimentally and numerically the dependency of the asymmetric energy flux on the parameters, and the key factors which affect the efficiency of the asymmetric energy flux are obtained. PMID:21728680

  1. Bandwidth Reduction For The Transmission Of Sign Language Over Telephone Lines

    NASA Astrophysics Data System (ADS)

    Boubekker, Mansouria

    1988-10-01

    This paper describes a system for the transmission of American Sign Language (ASL) over standard telephone lines. Video quality digital images require a transmission bandwidth at least 4000 times wider than that allowable by the standard voice telephone network. This study presents compression, segmentation and coding techniques that reduce the information content of visual images while preserving the meaning of the transmitted message. The resulting processed information can be transmitted at digital rates within the range of the commercially available 9600 baud modems. The simulated real-time animations of the decoded cartoon images used for the experimental data represent ASL and finger spelling with an intelligibility approximating 85%. This result is within the range of the intelligibility provided by speech communication over telephone lines.

  2. A review of return-stroke models based on transmission line theory

    NASA Astrophysics Data System (ADS)

    De Conti, Alberto; Silveira, Fernando H.; Visacro, Silvério; Cardoso, Thiago C. M.

    2015-12-01

    This paper presents a review of lightning return-stroke models based on transmission line theory. The reviewed models are classified in three different categories, namely discharge-type, lumped-excitation, and parameter-estimation models. An attempt is made to address the difficulties that some models experience in reproducing directly or indirectly observable features of lightning, such as current characteristics and remote electromagnetic fields. It is argued that most of these difficulties are related to a poor discretization of the lightning channel, to inconsistencies in the calculation of per-unit-length channel parameters, to uncertainties in the representation of the upper end of the channel, and to assuming an ideal switch to connect the channel to ground in the transition from leader to return stroke. Applications of transmission line return-stroke models are also outlined.

  3. Hybrid particle traps and conditioning procedure for gas insulated transmission lines

    DOEpatents

    Dale, Steinar J.; Cookson, Alan H.

    1982-01-01

    A gas insulated transmission line includes an outer sheath, an inner condor within the outer sheath, insulating supports supporting the inner conductor within the outer sheath, and an insulating gas electrically insulating the inner conductor from the outer sheath. An apertured particle trapping ring is disposed within the outer sheath, and the trapping ring has a pair of dielectric members secured at each longitudinal end thereof, with the dielectric members extending outwardly from the trapping ring along an arc. A support sheet having an adhesive coating thereon is secured to the trapping ring and disposed on the outer sheath within the low field region formed between the trapping ring and the outer sheath. A conditioning method used to condition the transmission line prior to activation in service comprises applying an AC voltage to the inner conductor in a plurality of voltage-time steps, with the voltage-time steps increasing in voltage magnitude while decreasing in time duration.

  4. Application guide for transmission line non-ceramic insulators. Final report

    SciTech Connect

    Phillips, A.; Childs, D.; Gela, G.

    1998-11-01

    Although there has been a dramatic increase in NCI use over the last decade, there is a wide variation in NCI design procedures, procurement specifications, installation and handling practices, live working techniques, and inspection and maintenance methods. Consequently, practicing utility engineers need a source of relevant information and recommendations on these subjects. EPRI has responded to this need by investing in a major multiyear research program on NCI. This report provides guidelines for electric utilities considering the use of non-ceramic insulators (NCI). It includes information on new installations, the replacement of conventional porcelain or glass (ceramic) insulators with NCI on existing transmission lines, and the assessment of NCI in service on transmission lines.

  5. AC and lightning performance of fiberglass crossarms aged in 115 kV transmission line

    SciTech Connect

    Grzybowski, S. . Dept. of Electrical and Computer Engineering); Jenkins, E.B. . Generation and Transmission Group)

    1993-10-01

    This paper presents the results of an investigation of the electrical performance of 115 kV transmission line fiberglass cross-arm used by Mississippi Power and Light Company. A transmission line fiberglass crossarm removed from service and companion cross-arms outdoors but not in service were examined. The evaluation of electrical performance was based on flashover voltage value at AC voltage and standard lightning impulses as well as under dry and wet conditions. The tests were performed in the Mississippi State University High Voltage Laboratory. The obtained flashover voltages show no large differences in electrical strength of fiberglass crossarms removed from service and those stored outdoors. The Added CFO voltage by fiberglass crossarm to the porcelain suspension insulators is presented versus the length of the fiberglass crossarm for dry and wet conditions.

  6. Transmission lines implementation on HDI flex circuits for the CMS tracker upgrade

    NASA Astrophysics Data System (ADS)

    Blanchot, G.; De Canio, F.; Gadek, T.; Honma, A.; Kovacs, M.; Rose, P.; Traversi, G.

    2016-01-01

    The upgrade of the CMS tracker at the HL-LHC relies on hybrid modules built on high density interconnecting flexible circuits. They contain several flip chip readout ASICs having high speed digital ports required for configuration and data readout, implemented as customized Scalable Low-Voltage Signalling (SLVS) differential pairs. This paper presents the connectivity requirements on the CMS tracker hybrids; it compares several transmission line implementations in terms of board area, achievable impedances and expected crosstalk. The properties obtained by means of simulations are compared with measurements made on a dedicated test circuit. The different transmission line implementations are also tested using a custom 65nm SLVS driver and receiver prototype ASIC.

  7. Mutual design: Overhead transmission lines and railroad facilities: Susceptibility program: Final report

    SciTech Connect

    Frazier, M.J.; Little, D.R.

    1989-07-01

    The sharing of common corridors by electric power transmission lines and railroad facilities can result in the coupling of unwanted electromagnetic energy from the power lines into nearby railroad systems. The coupling can result in voltage being induced onto the railroad system conductors that may compromise the inherent safety and reliability of the railroad signalling system. This broad-scoped research program, which is co-sponsored by EPRI and the AAR, is addressing the problem from two directions. This two volume report describes a Phase 1 effort to develop the methods and techniques for quantifying the signal system response to interference. 54 figs., 7 tabs.

  8. Transmission line relay mis-operation detection based on time-synchronized field data

    SciTech Connect

    Esmaeilian, Ahad; Popovic, Tomo; Kezunovic, Mladen

    2015-05-04

    In this paper, a real-time tool to detect transmission line relay mis-operation is implemented. The tool uses time-synchronized measurements obtained from both ends of the line during disturbances. The proposed fault analysis tool comes into the picture only after the protective device has operated and tripped the line. The proposed methodology is able not only to detect, classify, and locate transmission line faults, but also to accurately confirm whether the line was tripped due to a mis-operation of protective relays. The analysis report includes either detailed description of the fault type and location or detection of relay mis-operation. As such, it can be a source of very useful information to support the system restoration. The focus of the paper is on the implementation requirements that allow practical application of the methodology, which is illustrated using the field data obtained the real power system. Testing and validation is done using the field data recorded by digital fault recorders and protective relays. The test data included several hundreds of event records corresponding to both relay mis-operations and actual faults. The discussion of results addresses various challenges encountered during the implementation and validation of the presented methodology.

  9. On-chip sub-terahertz surface plasmon polariton transmission lines with mode converter in CMOS.

    PubMed

    Liang, Yuan; Yu, Hao; Wen, Jincai; Apriyana, Anak Agung Alit; Li, Nan; Luo, Yu; Sun, Lingling

    2016-01-01

    An on-chip low-loss and high conversion efficiency plasmonic waveguide converter is demonstrated at sub-THz in CMOS. By introducing a subwavelength periodic corrugated structure onto the transmission line (T-line) implemented by a top-layer metal, surface plasmon polaritons (SPP) are established to propagate signals with strongly localized surface-wave. To match both impedance and momentum of other on-chip components with TEM-wave propagation, a mode converter structure featured by a smooth bridge between the Ground coplanar waveguide (GCPW) with 50 Ω impedance and SPP T-line is proposed. To further reduce area, the converter is ultimately simplified to a gradual increment of groove with smooth gradient. The proposed SPP T-lines with the converter is designed and fabricated in the standard 65 nm CMOS process. Both near-field simulation and measurement results show excellent conversion efficiency from quasi-TEM to SPP modes in a broadband frequency range. The converter achieves wideband impedance matching (<-9 dB) with excellent transmission efficiency (averagely -1.9 dB) from 110 GHz-325 GHz. The demonstrated compact and wideband SPP T-lines with mode converter have shown great potentials to replace existing waveguides as future on-chip THz interconnects. To the best of the author's knowledge, this is the first time to demonstrate the (sub)-THz surface mode conversion on-chip in CMOS technology. PMID:27444782

  10. Transmission line relay mis-operation detection based on time-synchronized field data

    DOE PAGESBeta

    Esmaeilian, Ahad; Popovic, Tomo; Kezunovic, Mladen

    2015-05-04

    In this paper, a real-time tool to detect transmission line relay mis-operation is implemented. The tool uses time-synchronized measurements obtained from both ends of the line during disturbances. The proposed fault analysis tool comes into the picture only after the protective device has operated and tripped the line. The proposed methodology is able not only to detect, classify, and locate transmission line faults, but also to accurately confirm whether the line was tripped due to a mis-operation of protective relays. The analysis report includes either detailed description of the fault type and location or detection of relay mis-operation. As such,more » it can be a source of very useful information to support the system restoration. The focus of the paper is on the implementation requirements that allow practical application of the methodology, which is illustrated using the field data obtained the real power system. Testing and validation is done using the field data recorded by digital fault recorders and protective relays. The test data included several hundreds of event records corresponding to both relay mis-operations and actual faults. The discussion of results addresses various challenges encountered during the implementation and validation of the presented methodology.« less

  11. Electrical short pulses generation using a resonant tunneling diode nonlinear transmission line

    NASA Astrophysics Data System (ADS)

    Essimbi, B. Z.; Jäger, D.

    2012-03-01

    In this paper, the generation of short electrical pulses based on nonlinear active wave propagation effects along the resonant tunneling diode transmission line is studied. The principle of operation is discussed and it is shown by computer experiments that an input rectangular pulse as well as a sinusoidal input signal can be converted into a set of output spikes, suitable for A/D conversion at millimeter wave frequencies.

  12. Ignition of a Thermonuclear Detonation Wave in the Focus of Two Magnetically Insulated Transmission Lines

    NASA Astrophysics Data System (ADS)

    Winterberg, F.

    2003-04-01

    For the ignition of a thermonuclear detonation wave assisted by a strong magnetic field, it is proposed to use two concentrically nested magnetically insulated transmission lines, the inner one transmitting a high- voltage lower-current-, and the outer one a high-current lower-voltage- electromagnetic pulse drawn from two Marx generators. The concept has the potential of large thermonuclear gains with an input energy conceivably as small as 105 J.

  13. Development of Fault Point Locating System for Underground Transmission Lines using Optical Fiber Current Sensors

    NASA Astrophysics Data System (ADS)

    Kurosawa, Kiyoshi; Kondo, Reishi; Nasukawa, Shinsuke; Yamaguchi, Tatsushi; Amano, Kazuo

    Fault point locating systems based on surge current detection have recently been used for fast recovery of underground transmission line from the fault. Electromagnetic induction type sensors have mainly been used for detection of the surge current. However they are susceptible to electromagnetic noise which causes unstable system operation. To solve this problem, Tokyo Electric Power Co., Toko Electric Corporation and Fujikura Ltd., by a joint research, have developed a new system that applies optical fiber current sensors.

  14. Analysis of the ITER Low Field Side Reflectometer Transmission Line System

    SciTech Connect

    Hanson, Gregory R; Wilgen, John B; Bigelow, Tim S; Diem, Stephanie J; Biewer, Theodore M

    2010-01-01

    A critical issue in the design of the ITER low field side reflectometer is the transmission line (TL) system. A TL connects each launcher to a diagnostic instrument. Each TL will typically consist of 42 m of corrugated waveguide and up to ten miter bends. Important issues for the performance of the TL system are mode conversion and reflections. Minimizing these issues are critical to minimizing standing waves and phase errors. The performance of TL system is analyzed and recommendations are given.

  15. Attenuation of epsilon(sub eff) of coplanar waveguide transmission lines on silicon substrates

    NASA Technical Reports Server (NTRS)

    Taub, Susan R.; Young, Paul G.

    1993-01-01

    Attenuation and epsilon(sub eff) of Coplanar Waveguide (CPW) transmission lines were measured on Silicon substrates with resistivities ranging from 400 to greater than 30,000 ohm-cm, that have a 1000 angstrom coating of SiO2. Both attenuation and epsilon(sub eff) are given over the frequency range 5 to 40 GHz for various strip and slot widths. These measured values are also compared to the theoretical values.

  16. Horizontal cryogenic bushing for the termination of a superconducting power-transmission line

    DOEpatents

    Minati, K.F.; Morgan, G.H.; McNerney, A.J.; Schauer, F.

    1982-07-29

    A termination for a superconducting power transmission line is disclosed which is comprised of a standard air entrance insulated vertical bushing with an elbow, a horizontal cryogenic bushing linking the pressurized cryogenic cable environment to the ambient temperature bushing and a stress cone which terminated the cable outer shield and transforms the large radial voltage gradient in the cable dielectric into a much lower radial voltage gradient in the high density helium coolant at the cold end of the cryogenic bushing.

  17. Termination for a superconducting power transmission line including a horizontal cryogenic bushing

    DOEpatents

    Minati, Kurt F.; Morgan, Gerry H.; McNerney, Andrew J.; Schauer, Felix

    1984-01-01

    A termination for a superconducting power transmission line is disclosed which is comprised of a standard air entrance insulated vertical bushing with an elbow, a horizontal cryogenic bushing linking the pressurized cryogenic cable environment to the ambient temperature bushing and a stress cone which terminates the cable outer shield and transforms the large radial voltage gradient in the cable dielectric into a much lower radial voltage gradient in the high density helium coolant at the cold end of the cryogenic bushing.

  18. Particle trap with dielectric barrier for use in gas insulated transmission lines

    DOEpatents

    Dale, S.J.

    1982-06-15

    A gas-insulated transmission line includes an outer sheath, an inner conductor within the outer sheath, insulating supports supporting the inner conductor within the outer sheath, and an insulating gas electrically insulating the inner conductor from the outer sheath. An apertured particle trapping electrode is disposed within the outer sheath, and the electrode has a pair of dielectric members secured at each longitudinal end thereof, with the dielectric members extending outwardly from the apertured electrode. 7 figs.

  19. Particle trap with dielectric barrier for use in gas insulated transmission lines

    DOEpatents

    Dale, Steinar J.

    1982-01-01

    A gas-insulated transmission line includes an outer sheath, an inner conductor within the outer sheath, insulating supports supporting the inner conductor within the outer sheath, and an insulating gas electrically insulating the inner conductor from the outer sheath. An apertured particle trapping electrode is disposed within the outer sheath, and the electrode has a pair of dielectric members secured at each longitudinal end thereof, with the dielectric members extending outwardly from the apertured electrode.

  20. Sound transmission through triple-panel structures lined with poroelastic materials

    NASA Astrophysics Data System (ADS)

    Liu, Yu

    2015-03-01

    In this paper, previous theories on the prediction of sound transmission loss for a double-panel structure lined with poroelastic materials are extended to address the problem of a triple-panel structure. Six typical configurations are considered for a triple-panel structure based on the method of coupling the porous layers to the facing panels which determines critically the sound insulation performance of the system. The transfer matrix method is employed to solve the system by applying appropriate types of boundary conditions for these configurations. The transmission loss of the triple-panel structures in a diffuse sound field is calculated as a function of frequency and compared with that of corresponding double-panel structures. Generally, the triple-panel structure with poroelastic linings has superior acoustic performance to the double-panel counterpart, remarkably in the mid-high frequency range and possibly at low frequencies, by selecting appropriate configurations in which those with two air gaps in the structure exhibit the best overall performance over the entire frequency range. The poroelastic lining significantly lowers the cut-on frequency above which the triple-panel structure exhibits noticeably higher transmission loss. Compared with a double-panel structure, the wider range of system parameters for a triple-panel structure due to the additional partition provides more design space for tuning the sound insulation performance. Despite the increased structural complexity, the triple-panel structure lined with poroelastic materials has the obvious advantages in sound transmission loss while without the penalties in weight and volume, and is hence a promising replacement for the widely used double-panel sandwich structure.

  1. Ground Isolation Circuit for Isolating a Transmission Line from Ground Interference

    NASA Technical Reports Server (NTRS)

    Davidson, Craig A. (Inventor)

    1996-01-01

    This invention relates generally to a system for isolating ground interference from a transmission line, e.g., a ground isolation circuit for isolating a wideband transmission signal (such as a video signal) from ground by modulating the base signal on a carrier signal to permit the transmission signal to be isolated. In one embodiment, the circuit includes a pair of matched mixer circuits, each of which receives a carrier signal from the same oscillator circuit. The first mixer circuit also receives the baseband signal input, after appropriate conditioning, and modulates the baseband signal onto the carrier signal. In a preferred embodiment the carrier signal has a predetermined frequency which is at least two times the frequency of the baseband signal. The modulated signal (which can comprise an rf signal) is transmitted via an rf transmission line to the second mixer, which demodulates the rf signal to recover the baseband signal. Each port of the mixer connects to an isolation transformer to ensure isolation from ground interference. The circuit is considered to be of commercial value in that it can provide isolation between transmitting and receiving circuits, e.g., ground isolation for television circuits or high frequency transmitters, without the need for video transformers or optical isolators, thereby reducing the complexity, power consumption, and weight of the system.

  2. Fiber Bragg Grating sensor for fault detection in radial and network transmission lines.

    PubMed

    Moghadas, Amin A; Shadaram, Mehdi

    2010-01-01

    In this paper, a fiber optic based sensor capable of fault detection in both radial and network overhead transmission power line systems is investigated. Bragg wavelength shift is used to measure the fault current and detect fault in power systems. Magnetic fields generated by currents in the overhead transmission lines cause a strain in magnetostrictive material which is then detected by Fiber Bragg Grating (FBG). The Fiber Bragg interrogator senses the reflected FBG signals, and the Bragg wavelength shift is calculated and the signals are processed. A broadband light source in the control room scans the shift in the reflected signal. Any surge in the magnetic field relates to an increased fault current at a certain location. Also, fault location can be precisely defined with an artificial neural network (ANN) algorithm. This algorithm can be easily coordinated with other protective devices. It is shown that the faults in the overhead transmission line cause a detectable wavelength shift on the reflected signal of FBG and can be used to detect and classify different kind of faults. The proposed method has been extensively tested by simulation and results confirm that the proposed scheme is able to detect different kinds of fault in both radial and network system. PMID:22163416

  3. Improved Fault Classification in Series Compensated Transmission Line: Comparative Evaluation of Chebyshev Neural Network Training Algorithms.

    PubMed

    Vyas, Bhargav Y; Das, Biswarup; Maheshwari, Rudra Prakash

    2016-08-01

    This paper presents the Chebyshev neural network (ChNN) as an improved artificial intelligence technique for power system protection studies and examines the performances of two ChNN learning algorithms for fault classification of series compensated transmission line. The training algorithms are least-square Levenberg-Marquardt (LSLM) and recursive least-square algorithm with forgetting factor (RLSFF). The performances of these algorithms are assessed based on their generalization capability in relating the fault current parameters with an event of fault in the transmission line. The proposed algorithm is fast in response as it utilizes postfault samples of three phase currents measured at the relaying end corresponding to half-cycle duration only. After being trained with only a small part of the generated fault data, the algorithms have been tested over a large number of fault cases with wide variation of system and fault parameters. Based on the studies carried out in this paper, it has been found that although the RLSFF algorithm is faster for training the ChNN in the fault classification application for series compensated transmission lines, the LSLM algorithm has the best accuracy in testing. The results prove that the proposed ChNN-based method is accurate, fast, easy to design, and immune to the level of compensations. Thus, it is suitable for digital relaying applications. PMID:25314714

  4. Bias-field controlled phasing and power combination of gyromagnetic nonlinear transmission lines

    NASA Astrophysics Data System (ADS)

    Reale, D. V.; Bragg, J.-W. B.; Gonsalves, N. R.; Johnson, J. M.; Neuber, A. A.; Dickens, J. C.; Mankowski, J. J.

    2014-05-01

    Gyromagnetic Nonlinear Transmission Lines (NLTLs) generate microwaves through the damped gyromagnetic precession of the magnetic moments in ferrimagnetic material, and are thus utilized as compact, solid-state, frequency agile, high power microwave (HPM) sources. The output frequency of a NLTL can be adjusted by control of the externally applied bias field and incident voltage pulse without physical alteration to the structure of the device. This property provides a frequency tuning capability not seen in many conventional e-beam based HPM sources. The NLTLs developed and tested are mesoband sources capable of generating MW power levels in the L, S, and C bands of the microwave spectrum. For an individual NLTL the output power at a given frequency is determined by several factors including the intrinsic properties of the ferrimagnetic material and the transmission line structure. Hence, if higher power levels are to be achieved, it is necessary to combine the outputs of multiple NLTLs. This can be accomplished in free space using antennas or in a transmission line via a power combiner. Using a bias-field controlled delay, a transient, high voltage, coaxial, three port, power combiner was designed and tested. Experimental results are compared with the results of a transient COMSOL simulation to evaluate combiner performance.

  5. A parametric study of nonlinear seismic response analysis of transmission line structures.

    PubMed

    Tian, Li; Wang, Yanming; Yi, Zhenhua; Qian, Hui

    2014-01-01

    A parametric study of nonlinear seismic response analysis of transmission line structures subjected to earthquake loading is studied in this paper. The transmission lines are modeled by cable element which accounts for the nonlinearity of the cable based on a real project. Nonuniform ground motions are generated using a stochastic approach based on random vibration analysis. The effects of multicomponent ground motions, correlations among multicomponent ground motions, wave travel, coherency loss, and local site on the responses of the cables are investigated using nonlinear time history analysis method, respectively. The results show the multicomponent seismic excitations should be considered, but the correlations among multicomponent ground motions could be neglected. The wave passage effect has a significant influence on the responses of the cables. The change of the degree of coherency loss has little influence on the response of the cables, but the responses of the cables are affected significantly by the effect of coherency loss. The responses of the cables change little with the degree of the difference of site condition changing. The effect of multicomponent ground motions, wave passage, coherency loss, and local site should be considered for the seismic design of the transmission line structures. PMID:25133215

  6. Fiber Bragg Grating Sensor for Fault Detection in Radial and Network Transmission Lines

    PubMed Central

    Moghadas, Amin A.; Shadaram, Mehdi

    2010-01-01

    In this paper, a fiber optic based sensor capable of fault detection in both radial and network overhead transmission power line systems is investigated. Bragg wavelength shift is used to measure the fault current and detect fault in power systems. Magnetic fields generated by currents in the overhead transmission lines cause a strain in magnetostrictive material which is then detected by Fiber Bragg Grating (FBG). The Fiber Bragg interrogator senses the reflected FBG signals, and the Bragg wavelength shift is calculated and the signals are processed. A broadband light source in the control room scans the shift in the reflected signal. Any surge in the magnetic field relates to an increased fault current at a certain location. Also, fault location can be precisely defined with an artificial neural network (ANN) algorithm. This algorithm can be easily coordinated with other protective devices. It is shown that the faults in the overhead transmission line cause a detectable wavelength shift on the reflected signal of FBG and can be used to detect and classify different kind of faults. The proposed method has been extensively tested by simulation and results confirm that the proposed scheme is able to detect different kinds of fault in both radial and network system. PMID:22163416

  7. Extra-high voltage transmission lines: mechanisms of biological effects on honeybees. Final report

    SciTech Connect

    Greenberg, B.; Bindokas, V.

    1985-08-01

    The authors confirmed that bee exposure to E fields, including 100 kV/m, under the dry conditions cause no detectable effect on colony behavior. If, however, exposure occurs when moisture is present, or if bees are on a conductive surface, they become visibly disturbed, mortality is increased, abnormal propolization occurs, and colony development may be impaired. It seems plausible that bees on conductive surfaces within a hive under a 765-kV/m transmission line can perceive shocks from body currents induced by enhanced intra-hive E fields. Hives exposed under a 765-kV/m transmission line to an ambient E field of 7 kV/m have internal step-potential-induced currents and interchamber chort-circuit currents which range from one-half to several microamperes. Total hive currents can exceed 100 ..mu..A. Thus, induced hive currents exceed the empirical sting threshold by up to a factor of 100 and the E-field-induced body current by up to a factor of 1000. The degree of disturbance which could be produced by these intra-hive currents will eclipse that produced by perception of E-field-induced body currents. The authors therefore attribute the disturbance of colonies under a transmission line primarily to electric shock from induced hive currents. 10 refs., 51 figs., 18 tabs. (DT)

  8. New transmission line analogy applied to single and multilayered piezoelectric transducers.

    PubMed

    Dion, J L

    1993-01-01

    It is shown that a piezoelectric element vibrating in an extensional or shear mode can be modeled rigorously by systematic use of the transmission line analogy and the superposition theorem. A schematic representation of such an element which is in a way more intuitive than others representations is introduced. The stresses on the electroded faces are considered as sources of stress applied at the two ends of an acoustic transmission line, since the acoustical perturbations may be considered as originating on these faces. Using transmission line theory, a complete set of expressions is found for electrical impedance, acoustic stresses, and velocities. Computed results are exactly the same as those given by the classical method, even if the computation sequence is almost entirely different. An intuitive graphical model for a piezoelectric element is proposed. It is also shown that the acoustic velocities on opposite faces of an asymmetrical loaded piezoelectric plate are exactly equal at the antiresonance frequency when internal losses are neglected. The programs developed can be used efficiently for practical multilayered transducer design. PMID:18263222

  9. Bias-field controlled phasing and power combination of gyromagnetic nonlinear transmission lines.

    PubMed

    Reale, D V; Bragg, J-W B; Gonsalves, N R; Johnson, J M; Neuber, A A; Dickens, J C; Mankowski, J J

    2014-05-01

    Gyromagnetic Nonlinear Transmission Lines (NLTLs) generate microwaves through the damped gyromagnetic precession of the magnetic moments in ferrimagnetic material, and are thus utilized as compact, solid-state, frequency agile, high power microwave (HPM) sources. The output frequency of a NLTL can be adjusted by control of the externally applied bias field and incident voltage pulse without physical alteration to the structure of the device. This property provides a frequency tuning capability not seen in many conventional e-beam based HPM sources. The NLTLs developed and tested are mesoband sources capable of generating MW power levels in the L, S, and C bands of the microwave spectrum. For an individual NLTL the output power at a given frequency is determined by several factors including the intrinsic properties of the ferrimagnetic material and the transmission line structure. Hence, if higher power levels are to be achieved, it is necessary to combine the outputs of multiple NLTLs. This can be accomplished in free space using antennas or in a transmission line via a power combiner. Using a bias-field controlled delay, a transient, high voltage, coaxial, three port, power combiner was designed and tested. Experimental results are compared with the results of a transient COMSOL simulation to evaluate combiner performance. PMID:24880394

  10. Losses at magnetic nulls in pulsed-power transmission line systems

    NASA Astrophysics Data System (ADS)

    Mendel, C. W.; Pointon, T. D.; Savage, M. E.; Seidel, D. B.; Magne, I.; Vézinet, R.

    2006-04-01

    Pulsed-power systems operating in the terawatt regime must deal with large electron flows in vacuum transmission lines. In most parts of these transmission lines the electrons are constrained by the self-magnetic field to flow parallel to the conductors. In very low impedance systems, such as those used to drive Z-pinch radiation sources, the currents from multiple transmission lines are added together. This addition necessarily involves magnetic nulls that connect the positive and negative electrodes. The resultant local loss of magnetic insulation results in electron losses at the anode in the vicinity of the nulls. The lost current due to the magnetic null might or might not be appreciable. In some cases the lost current due to the null is not large, but is spatially localized, and may create a gas and plasma release from the anode that can lead to an excessive loss, and possibly to catastrophic damage to the hardware. In this paper we describe an analytic model that uses one geometric parameter (aside from straightforward hardware size measurements) that determines the loss to the anode, and the extent of the loss region when the driving source and load are known. The parameter can be calculated in terms of the magnetic field in the region of the null calculated when no electron flow is present. The model is compared to some experimental data, and to simulations of several different hardware geometries, including some cases with multiple nulls, and unbalanced feeds.

  11. Losses at magnetic nulls in pulsed-power transmission line systems

    SciTech Connect

    Mendel, C.W. Jr.; Pointon, T.D.; Savage, M.E.; Seidel, D.B.; Magne, I.; Vezinet, R.

    2006-04-15

    Pulsed-power systems operating in the terawatt regime must deal with large electron flows in vacuum transmission lines. In most parts of these transmission lines the electrons are constrained by the self-magnetic field to flow parallel to the conductors. In very low impedance systems, such as those used to drive Z-pinch radiation sources, the currents from multiple transmission lines are added together. This addition necessarily involves magnetic nulls that connect the positive and negative electrodes. The resultant local loss of magnetic insulation results in electron losses at the anode in the vicinity of the nulls. The lost current due to the magnetic null might or might not be appreciable. In some cases the lost current due to the null is not large, but is spatially localized, and may create a gas and plasma release from the anode that can lead to an excessive loss, and possibly to catastrophic damage to the hardware. In this paper we describe an analytic model that uses one geometric parameter (aside from straightforward hardware size measurements) that determines the loss to the anode, and the extent of the loss region when the driving source and load are known. The parameter can be calculated in terms of the magnetic field in the region of the null calculated when no electron flow is present. The model is compared to some experimental data, and to simulations of several different hardware geometries, including some cases with multiple nulls, and unbalanced feeds.

  12. Losses at magnetic nulls in pulsed-power transmission line systems.

    SciTech Connect

    Magne, I.; Savage, Mark Edward; Seidel, David Bruce; Mendel, Clifford Will, Jr.; Pointon, Timothy David; Vezinet, R.

    2004-08-01

    Pulsed-power systems operating in the terawatt regime must deal with large electron flows in vacuum transmission lines. In most parts of these transmission lines the electrons are constrained by the self-magnetic field to flow parallel to the conductors. In very low impedance systems, such as those used to drive Z-pinch radiation sources, the currents from multiple transmission lines are added together. This addition necessarily involves magnetic nulls that connect the positive and negative electrodes. The resultant local loss of magnetic insulation results in electron losses at the anode in the vicinity of the nulls. The lost current due to the magnetic null might or might not be appreciable. In some cases the lost current due to the null is not large, but is spatially localized, and may create a gas and plasma release from the anode that can lead to an excessive loss, and possibly to catastrophic damage to the hardware. In this paper we describe an analytic model that uses one geometric parameter (aside from straightforward hardware size measurements) that determines the loss to the anode, and the extent of the loss region when the driving source and load are known. The parameter can be calculated in terms of the magnetic field in the region of the null calculated when no electron flow is present. The model is compared to some experimental data, and to simulations of several different hardware geometries, including some cases with multiple nulls, and unbalanced feeds.

  13. Alleviation SSR and Low Frequency Power Oscillations in Series Compensated Transmission Line using SVC Supplementary Controllers

    NASA Astrophysics Data System (ADS)

    Kumar, Sanjiv; Kumar, Narendra

    2016-07-01

    In this work, supplementary sub-synchronous damping controllers (SSDC) are proposed for damping sub-synchronous oscillations in power systems with series compensated transmission lines. Series compensation have extensively been used as effective means of increasing the power transfer capability of a transmission lines and improving transient stability limits of power systems. Series compensation with transmission lines may cause sub-synchronous resonance (SSR). The eigenvalue investigation tool is used to ascertain the existence of SSR. It is shown that the addition of supplementary controller is able to stabilize all unstable modes for T-network model. Eigenvalue investigation and time domain transient simulation of detailed nonlinear system are considered to investigate the performance of the controllers. The efficacies of the suggested supplementary controllers are compared on the IEEE first benchmark model for computer simulations of SSR by means of time domain simulation in Matlab/Simulink environment. Supplementary SSDC are considered in order to compare effectiveness of SSDC during higher loading in alleviating the small signal stability problem.

  14. A Parametric Study of Nonlinear Seismic Response Analysis of Transmission Line Structures

    PubMed Central

    Wang, Yanming; Yi, Zhenhua

    2014-01-01

    A parametric study of nonlinear seismic response analysis of transmission line structures subjected to earthquake loading is studied in this paper. The transmission lines are modeled by cable element which accounts for the nonlinearity of the cable based on a real project. Nonuniform ground motions are generated using a stochastic approach based on random vibration analysis. The effects of multicomponent ground motions, correlations among multicomponent ground motions, wave travel, coherency loss, and local site on the responses of the cables are investigated using nonlinear time history analysis method, respectively. The results show the multicomponent seismic excitations should be considered, but the correlations among multicomponent ground motions could be neglected. The wave passage effect has a significant influence on the responses of the cables. The change of the degree of coherency loss has little influence on the response of the cables, but the responses of the cables are affected significantly by the effect of coherency loss. The responses of the cables change little with the degree of the difference of site condition changing. The effect of multicomponent ground motions, wave passage, coherency loss, and local site should be considered for the seismic design of the transmission line structures. PMID:25133215

  15. Fiber Bragg grating sensor for fault detection in high voltage overhead transmission lines

    NASA Astrophysics Data System (ADS)

    Moghadas, Amin

    2011-12-01

    A fiber optic based sensor capable of fault detection in both radial and network overhead transmission power line systems is investigated. Bragg wavelength shift is used to measure the fault current and detect fault in power systems. Magnetic fields generated by currents in the overhead transmission lines cause a strain in magnetostrictive material which is then detected by fiber Bragg grating (FBG) sensors. The Fiber Bragg interrogator senses the reflected FBG signals, and the Bragg wavelength shift is calculated and the signals are processed. A broadband light source in the control room scans the shift in the reflected signals. Any surge in the magnetic field relates to an increased fault current at a certain location. Also, fault location can be precisely defined with an artificial neural network (ANN) algorithm. This algorithm can be easily coordinated with other protective devices. It is shown that the faults in the overhead transmission line cause a detectable wavelength shift on the reflected signal of FBG sensors and can be used to detect and classify different kind of faults. The proposed method has been extensively tested by simulation and results confirm that the proposed scheme is able to detect different kinds of fault in both radial and network system.

  16. Bias-field controlled phasing and power combination of gyromagnetic nonlinear transmission lines

    SciTech Connect

    Reale, D. V. Bragg, J.-W. B.; Gonsalves, N. R.; Johnson, J. M.; Neuber, A. A.; Dickens, J. C.; Mankowski, J. J.

    2014-05-15

    Gyromagnetic Nonlinear Transmission Lines (NLTLs) generate microwaves through the damped gyromagnetic precession of the magnetic moments in ferrimagnetic material, and are thus utilized as compact, solid-state, frequency agile, high power microwave (HPM) sources. The output frequency of a NLTL can be adjusted by control of the externally applied bias field and incident voltage pulse without physical alteration to the structure of the device. This property provides a frequency tuning capability not seen in many conventional e-beam based HPM sources. The NLTLs developed and tested are mesoband sources capable of generating MW power levels in the L, S, and C bands of the microwave spectrum. For an individual NLTL the output power at a given frequency is determined by several factors including the intrinsic properties of the ferrimagnetic material and the transmission line structure. Hence, if higher power levels are to be achieved, it is necessary to combine the outputs of multiple NLTLs. This can be accomplished in free space using antennas or in a transmission line via a power combiner. Using a bias-field controlled delay, a transient, high voltage, coaxial, three port, power combiner was designed and tested. Experimental results are compared with the results of a transient COMSOL simulation to evaluate combiner performance.

  17. Performance Of The DIII-D ECH High Power Transmission Lines And Launching Systems

    NASA Astrophysics Data System (ADS)

    Cengher, Mirela; Lohr, J.; Gorelov, Y.; Torrezan, A.; Ponce, D.; Moeller, C.; Ellis, R. A.; Kolemen, E.

    2015-11-01

    The Electron Cyclotron Heating (ECH) transmission system on the DIII D tokamak consists of corrugated coaxial 31.75 mm waveguide transmission lines and steerable launching mirrors. Total power injected into plasma can reach up to 3.5 MW, with pulse length up to 5 seconds. The ECH power injected to the tokamak from each gyrotron is measured on a shot-to-shot basis and shows individual average injected powers from a gyrotron into the plasma between 540 and 700 kW. The transmission coefficient including the waveguide line and the MOU is between -1.04 dB and -1.43 dB. The maximum ECH energy injected into DIII-D is 16.6 MJ. The HE11 mode content is over 85 % for all the lines. The four dual waveguide launchers have increased poloidal scanning speed, and can steer the RF beams 40 degrees poloidally in 200 ms, with real-time poloidal motion control by the plasma control system. A new method of in-situ calibration of the mirror angle was used in conjunction with the upgrading of the encoders and motors for the launchers. Work supported by US DOE under DE-FC02-04ER54698 and DE-AC02-09CH11466.

  18. Design and Control of a 1-DOF MRI Compatible Pneumatically Actuated Robot with Long Transmission Lines.

    PubMed

    Yang, Bo; Tan, U-Xuan; McMillan, Alan; Gullapalli, Rao; Desai, Jaydev P

    2011-12-01

    This paper presents the design and control of an MRI-compatible 1-DOF needle driver robot and its precise position control using pneumatic actuation with long transmission lines. MRI provides superior image quality compared to other imaging modalities such as CT or ultrasound, but imposes severe limitations on the material and actuator choice (to prevent image distortion) due to its strong magnetic field. We are primarily interested in developing a pneumatically actuated breast biopsy robot with a large force bandwidth and precise targeting capability during radio-frequency ablation (RFA) of breast tumor, and exploring the possibility of using long pneumatic transmission lines from outside the MRI room to the device in the magnet to prevent any image distortion whatsoever. This paper presents a model of the entire pneumatic system. The pneumatic lines are approximated by a first order system with time delay, because its dynamics are governed by the telegraph equation with varying coefficients and boundary conditions, which cannot be solved precisely. The slow response of long pneumatic lines and valve subsystems make position control challenging. This is further compounded by the presence of non-uniform friction in the device. Sliding mode control (SMC) was adopted, where friction was treated as an uncertainty term to drive the system onto the sliding surface. Three different controllers were designed, developed, and evaluated to achieve precise position control of the RFA probe. Experimental results revealed that all SMCs gave satisfactory performance with long transmission lines. We also performed several experiments with a 3-DOF fiber-optic force sensor attached to the needle driver to evaluate the performance of the device in the MRI under continuous imaging. PMID:22058649

  19. Design and Control of a 1-DOF MRI Compatible Pneumatically Actuated Robot with Long Transmission Lines

    PubMed Central

    Yang, Bo; Tan, U-Xuan; McMillan, Alan; Gullapalli, Rao; Desai, Jaydev P.

    2011-01-01

    This paper presents the design and control of an MRI-compatible 1-DOF needle driver robot and its precise position control using pneumatic actuation with long transmission lines. MRI provides superior image quality compared to other imaging modalities such as CT or ultrasound, but imposes severe limitations on the material and actuator choice (to prevent image distortion) due to its strong magnetic field. We are primarily interested in developing a pneumatically actuated breast biopsy robot with a large force bandwidth and precise targeting capability during radio-frequency ablation (RFA) of breast tumor, and exploring the possibility of using long pneumatic transmission lines from outside the MRI room to the device in the magnet to prevent any image distortion whatsoever. This paper presents a model of the entire pneumatic system. The pneumatic lines are approximated by a first order system with time delay, because its dynamics are governed by the telegraph equation with varying coefficients and boundary conditions, which cannot be solved precisely. The slow response of long pneumatic lines and valve subsystems make position control challenging. This is further compounded by the presence of non-uniform friction in the device. Sliding mode control (SMC) was adopted, where friction was treated as an uncertainty term to drive the system onto the sliding surface. Three different controllers were designed, developed, and evaluated to achieve precise position control of the RFA probe. Experimental results revealed that all SMCs gave satisfactory performance with long transmission lines. We also performed several experiments with a 3-DOF fiber-optic force sensor attached to the needle driver to evaluate the performance of the device in the MRI under continuous imaging. PMID:22058649

  20. Accurate circuit analysis of resonant-type left handed transmission lines with inter-resonator coupling

    NASA Astrophysics Data System (ADS)

    Gil, I.; Bonache, J.; Gil, M.; García-García, J.; Martín, F.; Marqués, R.

    2006-10-01

    In this paper, a circuit model for the description of left handed transmission lines based on complementary split rings resonators (CSRRs) is proposed. As compared to previous models, coupling between adjacent resonators is included in the present work. The conditions that make this coupling significant are discussed. Specifically, it will be shown that it is barely present when circular CSRRs are used to implement the left handed transmission line. However, if the line is loaded with rectangular CSRRs separated by a small distance, inter-resonator coupling is important and it significantly influences the electromagnetic behavior of the structures. It will be also shown that under low or moderate coupling, it is possible to describe the structures by means of a simplified model with modified parameters. Several prototype devices with different CSRR topologies and coupling levels have been fabricated to illustrate the phenomenology associated with these structures and the accuracy of their model descriptions. The results of this work can be of interest for the design of planar microwave circuits based on CSRR left handed lines.