  1. Multiphase contrast-saline mixture injection with dual-flow in 64-row MDCT coronary CTA.

    PubMed

    Cao, Lizhen; Du, Xiangying; Li, Pengyu; Liu, Yaou; Li, Kuncheng

    2009-03-01

    To explore the feasibility of multiphase contrast-saline mixture with dual-flow injection technique for visualization of right ventricular (RV) cavity and interventricular septum (IVS) in 64-row multidetector computed tomography (MDCT) coronary angiography. Twenty-four patients underwent coronary CT angiography (CTA) imaging with 64-row MDCT. In twelve patients (group A), 60 ml contrast medium (CM) bolus was followed by 40 ml saline, and in the other twelve patients (group B), 50 ml CM bolus was followed by 50 ml contrast-saline mixture at 60:40 ratio. The CM, saline and contrast-saline mixture flow rate were all 5.0 ml/s. Two experienced radiologists measured the CT values of ascending aorta, descending aorta, pulmonary artery and RV, rated the uniformity of RV cavity, the visualization of coronary arteries and IVS independently. By Kappa test, agreement between the two radiologists was 0.93 and 0.86 concerning the CT value measurements and the grades of the three indexes, respectively. By t-test, the mean CT values of ascending aorta and descending aorta of the two groups had no statistical difference (t=1.459, P>0.05; t=1.619, P>0.05); while the mean CT values of pulmonary artery and RV cavity had statistical differences (t=8.316, P<0.05; t=10.372, P<0.05). By two-related rank sum test, according to the visualization of coronary arteries and the uniformity of RV cavity, there were no statistical differences (U=66.00, P>0.05; U=54.00, P>0.05); while according to the visualization of IVS, group B was better than group A (U=8.00, P<0.05). In coronary CTA, a contrast-saline mixture after CM bolus can provide clear visualization of RV and IVS and LV without impairing coronary CTA image.

  2. Multidetector-row CT with a 64-row amorphous silicon flat panel detector

    NASA Astrophysics Data System (ADS)

    Shapiro, Edward G.; Colbeth, Richard E.; Daley, Earl T.; Job, Isaias D.; Mollov, Ivan P.; Mollov, Todor I.; Pavkovich, John M.; Roos, Pieter G.; Star-Lack, Josh M.; Tognina, Carlo A.

    2007-03-01

    A unique 64-row flat panel (FP) detector has been developed for sub-second multidetector-row CT (MDCT). The intent was to explore the image quality achievable with relatively inexpensive amorphous silicon (a-Si) compared to existing diagnostic scanners with discrete crystalline diode detectors. The FP MDCT system is a bench-top design that consists of three FP modules. Each module uses a 30 cm x 3.3 cm a-Si array with 576 x 64 photodiodes. The photodiodes are 0.52 mm x 0.52 mm, which allows for about twice the spatial resolution of most commercial MDCT scanners. The modules are arranged in an overlapping geometry, which is sufficient to provide a full-fan 48 cm diameter scan. Scans were obtained with various detachable scintillators, e.g. ceramic Gd IIO IIS, particle-in-binder Gd IIO IIS:Tb and columnar CsI:Tl. Scan quality was evaluated with a Catphan-500 performance phantom and anthropomorphic phantoms. The FP MDCT scans demonstrate nearly equivalent performance scans to a commercial 16-slice MDCT scanner at comparable 10 - 20 mGy/100mAs doses. Thus far, a high contrast resolution of 15 lp/cm and a low contrast resolution of 5 mm @ 0.3 % have been achieved on 1 second scans. Sub-second scans have been achieved with partial rotations. Since the future direction of MDCT appears to be in acquiring single organ coverage per scan, future efforts are planned for increasing the number of detector rows beyond the current 64- rows.

  3. Application of MPVR and TL-VR with 64-row MDCT in neonates with congenital EA and distal TEF.

    PubMed

    Wen, Yang; Peng, Yun; Zhai, Ren-You; Li, Ying-Zi

    2011-03-28

    To assess the application of multiple planar volume reconstruction (MPVR) and three-dimensional (3D) transparency lung volume rendering (TL-VR) with 64-row multidetector-row computed tomography (MDCT) in neonates with congenital esophageal atresia (EA) and distal tracheoesophageal fistula (TEF). Twenty neonates (17 boys, 3 girls) with EA and distal TEF at a mean age of 4.6 d (range 1-16 d) were enrolled in this study. A helical scan of 64-row MDCT was performed at the 64 mm × 0.625 mm collimation. EA and TEF were reconstructed with MPVR and TL-VR, respectively. Initial diagnosis of EA was made by chest radiography showing the inserted catheter in the proximal blind-ended esophageal pouch. Manifestations of MDCT images were compared with the findings at surgery. MDCT showed the proximal and distal esophageal pouches in 20 cases. No significant difference was observed in gaps between the proximal and distal esophageal pouches detected by MPVR and TL-VR. The lengths of gaps between the proximal and distal esophageal pouches detected by MPVR and TL-VR correlated well with the findings at surgery (R = 0.87, P < 0.001). The images of MPVR revealed the orifice of TEF in 13 cases, while TL-VR images showed the orifice of TEF in 4 cases. EA and distal TEF can be reconstructed using MPVR and TL-VR of 64-row MDCT, which is a noninvasive technique to demonstrate the distal esophageal pouches and inter-pouch distance in neonates with EA and distal TEF.

  4. Dual source heat pump

    DOEpatents

    Ecker, Amir L.; Pietsch, Joseph A.

    1982-01-01

    What is disclosed is a heat pump apparatus for conditioning a fluid characterized by a fluid handler and path for circulating the fluid in heat exchange relationship with a refrigerant fluid; at least two refrigerant heat exchangers, one for effecting heat exchange with the fluid and a second for effecting heat exchange between refrigerant and a heat exchange fluid and the ambient air; a compressor for efficiently compressing the refrigerant; at least one throttling valve for throttling liquid refrigerant; a refrigerant circuit; refrigerant; a source of heat exchange fluid; heat exchange fluid circulating device and heat exchange fluid circuit for circulating the heat exchange fluid in heat exchange relationship with the refrigerant; and valves or switches for selecting the heat exchangers and direction of flow of the refrigerant therethrough for selecting a particular mode of operation. The heat exchange fluid provides energy for defrosting the second heat exchanger when operating in the air source mode and also provides a alternate source of heat.

  5. Comparison of dynamic contrast-enhanced 3T MR and 64-row multidetector CT angiography for the localization of spinal dural arteriovenous fistulas.

    PubMed

    Oda, S; Utsunomiya, D; Hirai, T; Kai, Y; Ohmori, Y; Shigematsu, Y; Iryo, Y; Uetani, H; Azuma, M; Yamashita, Y

    2014-02-01

    For the localization of spinal dural arteriovenous fistulas, it is not determined whether dynamic contrast-enhanced MRA is more reliable than multidetector CTA. The aim of this study was to compare the agreement between intra-arterial DSA, dynamic contrast-enhanced MRA at 3T, and 64-row multidetector CTA for the localization of spinal dural arteriovenous fistulas. We enrolled 12 consecutive patients (11 men, 1 woman; age range, 46-83 years; mean, 65 years) who underwent preoperative dynamic contrast-enhanced MRA at 3T and 64-row multidetector CTA. The spinal dural arteriovenous fistula location was confirmed by intra-arterial DSA as the reference standard. Two reviewers independently evaluated the level of the artery feeding the spinal dural arteriovenous fistula on the basis of continuity between the feeder and abnormal spinal vessels on 3T dynamic contrast-enhanced MRA and 64-row multidetector CTA images. Interobserver and intermodality agreement was determined by calculation of the κ coefficient. On DSA, the vessel feeding the spinal dural arteriovenous fistula was the intercostal artery (7 cases), the lumbar artery (3 cases), and the internal iliac artery or the ascending pharyngeal artery (1 case each). For the fistula level, interobserver agreement was excellent for 3T dynamic contrast-enhanced MRA (κ = 0.97; 95% CI, 0.92-1.00) and very good for 64-row multidetector CTA (κ = 0.84; 95% CI, 0.72-0.96). Intermodality agreement with DSA was good for 3T dynamic contrast-enhanced MRA (κ = 0.78; 95% CI, 0.49-1.00) and moderate for 64-row multidetector CTA (κ = 0.41; 95% CI, 0.020-0.84). For the localization of spinal dural arteriovenous fistulas, 3T dynamic contrast-enhanced MRA may be more reliable than 64-row multidetector CTA.

  6. Comparison of Reconstruction Intervals in Routine ECG-Pulsed 64-Row-MSCT Coronary Angiography in Frequency Controlled Patients

    SciTech Connect

    Frydrychowicz, Alex Pache, Gregor; Saueressig, Ulrich; Foell, Daniela; Kotter, Elmar; Langer, Mathias; Bley, Thorsten A.

    2007-02-15

    Purpose. In light of the increasing use and acceptance of multislice computed tomography (MSCT) coronary angiography it was the purpose of this study to compare reconstruction intervals used in a routine ECG-pulsed MSCT coronary artery angiography setting with frequency controlled patients. Methods. Examinations were performed on a Siemens Somatom Sensation 64 scanner with a total of 110 ml of contrast agent and ECG pulsing (interval from 40% to 70%) after oral application of a {beta}-blocker if the heart rate was higher than 65 bpm. All human subjects were referred for the evaluation of suspected coronary artery disease. Coronary artery segments were evaluated by two experienced radiologists in a consensus reading. A ranking of diagnostic image quality (from 1 (no evaluation possible) to 5 (excellent image quality)) was statistically evaluated by Wilcoxon Signed Rank Test. Results. In 45 patients (30 male, 15 female, age 63.8 {+-} 12.1 years) we detected a significant advantage of the 60% reconstruction interval over 40%, 50%, and 70% (for each p < 0.05). In cases of sudden arrhythmia or movement during the scan, additional reconstruction intervals within the ECG-pulsed reconstruction intervals remained necessary for diagnosis. Conclusion. In a routine diagnostic setting with frequency controlled patients and ECG pulsing the 60% reconstruction interval can be considered superior for the initial diagnosis in 64-row multislice computed tomography coronary angiography. However, further information can be derived from various reconstruction intervals such as 40% and 70%.

  7. Role of Computer Aided Diagnosis (CAD) in the detection of pulmonary nodules on 64 row multi detector computed tomography.

    PubMed

    Prakashini, K; Babu, Satish; Rajgopal, K V; Kokila, K Raja

    2016-01-01

    To determine the overall performance of an existing CAD algorithm with thin-section computed tomography (CT) in the detection of pulmonary nodules and to evaluate detection sensitivity at a varying range of nodule density, size, and location. A cross-sectional prospective study was conducted on 20 patients with 322 suspected nodules who underwent diagnostic chest imaging using 64-row multi-detector CT. The examinations were evaluated on reconstructed images of 1.4 mm thickness and 0.7 mm interval. Detection of pulmonary nodules, initially by a radiologist of 2 years experience (RAD) and later by CAD lung nodule software was assessed. Then, CAD nodule candidates were accepted or rejected accordingly. Detected nodules were classified based on their size, density, and location. The performance of the RAD and CAD system was compared with the gold standard that is true nodules confirmed by consensus of senior RAD and CAD together. The overall sensitivity and false-positive (FP) rate of CAD software was calculated. Of the 322 suspected nodules, 221 were classified as true nodules on the consensus of senior RAD and CAD together. Of the true nodules, the RAD detected 206 (93.2%) and 202 (91.4%) by the CAD. CAD and RAD together picked up more number of nodules than either CAD or RAD alone. Overall sensitivity for nodule detection with the CAD program was 91.4%, and FP detection per patient was 5.5%. The CAD showed comparatively higher sensitivity for nodules of size 4-10 mm (93.4%) and nodules in hilar (100%) and central (96.5%) location when compared to RAD's performance. CAD performance was high in detecting pulmonary nodules including the small size and low-density nodules. CAD even with relatively high FP rate, assists and improves RAD's performance as a second reader, especially for nodules located in the central and hilar region and for small nodules by saving RADs time.

  8. Role of Computer Aided Diagnosis (CAD) in the detection of pulmonary nodules on 64 row multi detector computed tomography

    PubMed Central

    Prakashini, K; Babu, Satish; Rajgopal, KV; Kokila, K Raja

    2016-01-01

    Aims and Objectives: To determine the overall performance of an existing CAD algorithm with thin-section computed tomography (CT) in the detection of pulmonary nodules and to evaluate detection sensitivity at a varying range of nodule density, size, and location. Materials and Methods: A cross-sectional prospective study was conducted on 20 patients with 322 suspected nodules who underwent diagnostic chest imaging using 64-row multi-detector CT. The examinations were evaluated on reconstructed images of 1.4 mm thickness and 0.7 mm interval. Detection of pulmonary nodules, initially by a radiologist of 2 years experience (RAD) and later by CAD lung nodule software was assessed. Then, CAD nodule candidates were accepted or rejected accordingly. Detected nodules were classified based on their size, density, and location. The performance of the RAD and CAD system was compared with the gold standard that is true nodules confirmed by consensus of senior RAD and CAD together. The overall sensitivity and false-positive (FP) rate of CAD software was calculated. Observations and Results: Of the 322 suspected nodules, 221 were classified as true nodules on the consensus of senior RAD and CAD together. Of the true nodules, the RAD detected 206 (93.2%) and 202 (91.4%) by the CAD. CAD and RAD together picked up more number of nodules than either CAD or RAD alone. Overall sensitivity for nodule detection with the CAD program was 91.4%, and FP detection per patient was 5.5%. The CAD showed comparatively higher sensitivity for nodules of size 4–10 mm (93.4%) and nodules in hilar (100%) and central (96.5%) location when compared to RAD's performance. Conclusion: CAD performance was high in detecting pulmonary nodules including the small size and low-density nodules. CAD even with relatively high FP rate, assists and improves RAD's performance as a second reader, especially for nodules located in the central and hilar region and for small nodules by saving RADs time. PMID:27578931

  9. Exploiting dual otoacoustic emission sources

    NASA Astrophysics Data System (ADS)

    Abdala, Carolina; Kalluri, Radha

    2015-12-01

    Two distinct processes generate otoacoustic emissions (OAEs). Reflection-source emissions, here recorded as stimulus frequency OAEs, are optimally informative at low sound levels and are more sensitive to slight hearing loss; they have been linked to cochlear amplifier gain and tuning. Distortion-source emissions are strongest at moderate-high sound levels and persist despite mild hearing loss; they likely originate in the nonlinear process of hair cell transduction. In this preliminary study, we exploit the unique features of each by generating a combined reflection-distortion OAE profile in normal hearing and hearing-impaired ears. Distortion-product (DP) and stimulus-frequency (SF) OAEs were recorded over a broad range of stimulus levels and frequencies. Individual I/O and transfer functions were generated for both emission types in each ear, and OAE peak strength, compression threshold, and rate of compression were calculated. These combined SFOAE and DPOAE features in normal and hearing-impaired ears may provide a potentially informative and novel index of hearing loss. This is an initial step toward utilizing OAE source in characterizing cochlear function and dysfunction.

  10. Dual energy with dual source CT and kVp switching with single source CT: a comparison of dual energy performance

    NASA Astrophysics Data System (ADS)

    Grasruck, M.; Kappler, S.; Reinwand, M.; Stierstorfer, K.

    2009-02-01

    Stimulated by the introduction of clinical dual source CT, the interest in dual energy methods has been increasing in the past years. Whereas the potential of material decomposition by dual energy methods is known since the early 1980ies, the realization of dual energy methods is a wide field of today's research. Energy separation can be achieved with energy selective detectors or by varying X-ray source spectra. This paper focuses on dual energy techniques with varying X-ray spectra. These can be provided by dual source CT devices, operated with different kVp settings on each tube. Excellent spectral separation is the key property for use in clinical routine. The drawback of higher cost for two tubes and two detectors leads to an alternative realization, where a single source CT yields different spectra by fast kVp switching from reading to reading. This provides access to dual-energy methods in single source CT. However, this technique comes with some intrinsic limitations. The maximum X-ray flux is reduced in comparison to the dual source system. The kVp rise and fall time between each reading reduces the spectral separation. In comparison to dual source CT, for a constant number of projections per energy spectrum the temporal resolution is reduced; a reasonable trade of between reduced numbers of projection and limited temporal resolution has to be found. The overall dual energy performance is the guiding line for our investigations. We present simulations and measurements which benchmark both solutions in terms of spectral behavior, especially of spectral separation.

  11. Note: A simple dual polarity dual nanoelectrospray ionization source for ion/ion reactions

    NASA Astrophysics Data System (ADS)

    Myer, Matthew J.; Danell, Ryan M.; Danell, Allison S.

    2010-06-01

    A continuously operated dual polarity dual nanoelectrospray ionization source has been constructed and tested. A commercial quadrupole ion trap mass spectrometer was modified to accumulate and trap ions of opposite charge. All changes to the commercial three-dimensional quadrupole ion trap have been made external to the instrument outside of the vacuum system. Few hardware modifications were required because the two emitters send ion beams through the same transmission guides. Computer controlled source voltage polarities are switched quickly and efficiently to transmit one of two continuously generated ion beams. With customized software, this design has proved simple to implement and to operate.

  12. Dual-Cathode Electron-Beam Source

    NASA Technical Reports Server (NTRS)

    Bradley, James G.; Conley, Joseph M.; Wittry, David B.

    1988-01-01

    Beam from either cathode electromagnetically aligned with exit port. Electron beam from either of two cathodes deflected by magnetic and electric fields to central axis. Mechanical alignment of beam easy because cathode axes, anode apertures, and electron trajectories coplanar. Applications where uninterrupted service needed: scanning electron microscopes, transmission electron microscopes, electron-beam lithography equipment, Auger instruments, and microfocused x-ray sources.

  13. Potential Sources of Bias in Dual Language Achievement Tests.

    ERIC Educational Resources Information Center

    Cabello, Beverly

    Potential sources of bias in dual language achievement tests were identified and examined. Content, concepts, and vocabulary presented in monolingual English curricula may differ drastically from those presented in bilingual curricula. The Spanish or English versions of the Comprehensive Tests of Basic Skills (CTBS) were administered to 1259…

  14. The HelCat dual-source plasma device.

    PubMed

    Lynn, Alan G; Gilmore, Mark; Watts, Christopher; Herrea, Janis; Kelly, Ralph; Will, Steve; Xie, Shuangwei; Yan, Lincan; Zhang, Yue

    2009-10-01

    The HelCat (Helicon-Cathode) device has been constructed to support a broad range of basic plasma science experiments relevant to the areas of solar physics, laboratory astrophysics, plasma nonlinear dynamics, and turbulence. These research topics require a relatively large plasma source capable of operating over a broad region of parameter space with a plasma duration up to at least several milliseconds. To achieve these parameters a novel dual-source system was developed utilizing both helicon and thermionic cathode sources. Plasma parameters of n(e) approximately 0.5-50 x 10(18) m(-3) and T(e) approximately 3-12 eV allow access to a wide range of collisionalities important to the research. The HelCat device and initial characterization of plasma behavior during dual-source operation are described.

  15. Cost Analysis for Dual Source Weapon Procurement

    DTIC Science & Technology

    1983-10-01

    in the early stages of the development of a new sys- tam, the cost depends on so many variables that the estimating prccess necessarily requires...proptotyp-, hard- ware development leading to a "fly-off". 2. Obtaining an item from a new source subsequent to a default termination. 3. Component...Raised 2. 1 PRODCTION RITES =Aquisition experience in the DOD has shown that production rates for new military weapon systems are subject :o fre

  16. Dual radio frequency plasma source: Understanding via electrical asymmetry effect

    SciTech Connect

    Bora, B.; Bhuyan, H.; Favre, M.; Wyndham, E.; Wong, C. S.

    2013-04-21

    On the basis of the global model, the influences of driving voltage and frequency on electron heating in geometrically symmetrical dual capacitively coupled radio frequency plasma have been investigated. Consistent with the experimental and simulation results, non-monotonic behavior of dc self bias and plasma heating with increasing high frequency is observed. In addition to the local maxima of plasma parameters for the integer values of the ratio between the frequencies ({xi}), ourstudies also predict local maxima for odd integer values of 2{xi} as a consequence of the electrical asymmetry effect produced by dual frequency voltage sources.

  17. Dual source and dual detector arrays tetrahedron beam computed tomography for image guided radiotherapy.

    PubMed

    Kim, Joshua; Lu, Weiguo; Zhang, Tiezhi

    2014-02-07

    Cone-beam computed tomography (CBCT) is an important online imaging modality for image guided radiotherapy. But suboptimal image quality and the lack of a real-time stereoscopic imaging function limit its implementation in advanced treatment techniques, such as online adaptive and 4D radiotherapy. Tetrahedron beam computed tomography (TBCT) is a novel online imaging modality designed to improve on the image quality provided by CBCT. TBCT geometry is flexible, and multiple detector and source arrays can be used for different applications. In this paper, we describe a novel dual source-dual detector TBCT system that is specially designed for LINAC radiation treatment machines. The imaging system is positioned in-line with the MV beam and is composed of two linear array x-ray sources mounted aside the electrical portal imaging device and two linear arrays of x-ray detectors mounted below the machine head. The detector and x-ray source arrays are orthogonal to each other, and each pair of source and detector arrays forms a tetrahedral volume. Four planer images can be obtained from different view angles at each gantry position at a frame rate as high as 20 frames per second. The overlapped regions provide a stereoscopic field of view of approximately 10-15 cm. With a half gantry rotation, a volumetric CT image can be reconstructed having a 45 cm field of view. Due to the scatter rejecting design of the TBCT geometry, the system can potentially produce high quality 2D and 3D images with less radiation exposure. The design of the dual source-dual detector system is described, and preliminary results of studies performed on numerical phantoms and simulated patient data are presented.

  18. Dual source and dual detector arrays tetrahedron beam computed tomography for image guided radiotherapy

    NASA Astrophysics Data System (ADS)

    Kim, Joshua; Lu, Weiguo; Zhang, Tiezhi

    2014-02-01

    Cone-beam computed tomography (CBCT) is an important online imaging modality for image guided radiotherapy. But suboptimal image quality and the lack of a real-time stereoscopic imaging function limit its implementation in advanced treatment techniques, such as online adaptive and 4D radiotherapy. Tetrahedron beam computed tomography (TBCT) is a novel online imaging modality designed to improve on the image quality provided by CBCT. TBCT geometry is flexible, and multiple detector and source arrays can be used for different applications. In this paper, we describe a novel dual source-dual detector TBCT system that is specially designed for LINAC radiation treatment machines. The imaging system is positioned in-line with the MV beam and is composed of two linear array x-ray sources mounted aside the electrical portal imaging device and two linear arrays of x-ray detectors mounted below the machine head. The detector and x-ray source arrays are orthogonal to each other, and each pair of source and detector arrays forms a tetrahedral volume. Four planer images can be obtained from different view angles at each gantry position at a frame rate as high as 20 frames per second. The overlapped regions provide a stereoscopic field of view of approximately 10-15 cm. With a half gantry rotation, a volumetric CT image can be reconstructed having a 45 cm field of view. Due to the scatter rejecting design of the TBCT geometry, the system can potentially produce high quality 2D and 3D images with less radiation exposure. The design of the dual source-dual detector system is described, and preliminary results of studies performed on numerical phantoms and simulated patient data are presented.

  19. Cerebral artery evaluation of dual energy CT angiography with dual source CT.

    PubMed

    Ma, Rui; Liu, Cheng; Deng, Kai; Song, Shao-juan; Wang, Dao-ping; Huang, Ling

    2010-05-05

    Conventional computed tomography angiography (CTA) is time consuming, user-dependent and has poor image quality in skull base region. This study assessed the feasibility of a new method, dual energy CTA for depicting the cerebral artery. Phantom scan was done with head CTA sequences on dual source CT and 64 spiral CT for radiation dose calculation. Dual energy CTA was done with dual source CT on 36 patients who were suspected of having cerebral vascular disease. Three series axial images in 0.75 mm thick, 0.4 mm increment were acquired, which were named with 80 kV, 140 kV and merged images; 80 kV and 140 kV images were transferred into dual energy software, and maximum intensity projection (MIP) image was generated quickly by dual energy bone remove (DEBR group); merged images were transferred into In Space software to acquire MIP image through manual conventional bone remove (CoBR group). Post processing time and reading time were compared. Image qualities of the two groups were compared, mainly focusing on skull base segments of internal carotid artery and bone subtraction. ANOVA and SNK tests were applied for radiation dose comparison. Student's t test and Wilcoxon rank sum test were applied for assessing differences between data for significance. Cohen's kappa was used for interobserver agreement. Radiation dose of phantom scan showed dual energy CTA was between digital bone subtraction and conventional CTA. The post processing time and reading time were much shorter in DEBR than CoBR, and image quality in skull base was much higher in DEBR than CoBR (P < 0.01). There was no significant difference for suprasellar vessels between two groups (P > 0.5). Interobserver agreement for all vessel segments was excellent (kappa = 0.97). Dual energy CTA is a reliable, new modality for depicting cerebral artery, overcoming the limitation of conventional CTA in the skull base region. It can save much time in post processing and reading than conventional CTA.

  20. Dual-source CT for chest pain assessment

    PubMed Central

    Nikolaou, Konstantin; Becker, Alexander; Leber, Alexander W.; Rist, Carsten; Wintersperger, Bernd J.; Reiser, Maximilian F.; Becker, Christoph R.

    2007-01-01

    Comprehensive CT angiography protocols offering a simultaneous evaluation of pulmonary embolism, coronary stenoses and aortic disease are gaining attractiveness with recent CT technology. The aim of this study was to assess the diagnostic accuracy of a specific dual-source CT protocol for chest pain assessment. One hundred nine patients suffering from acute chest pain were examined on a dual-source CT scanner with ECG gating at a temporal resolution of 83 ms using a body-weight-adapted contrast material injection regimen. The images were evaluated for the cause of chest pain, and the coronary findings were correlated to invasive coronary angiography in 29 patients (27%). The files of patients with negative CT examinations were reviewed for further diagnoses. Technical limitations were insufficient contrast opacification in six and artifacts from respiration in three patients. The most frequent diagnoses were coronary stenoses, valvular and myocardial disease, pulmonary embolism, aortic aneurysm and dissection. Overall sensitivity for the identification of the cause of chest pain was 98%. Correlation to invasive coronary angiography showed 100% sensitivity and negative predictive value for coronary stenoses. Dual-source CT offers a comprehensive, robust and fast chest pain assessment. PMID:18034246

  1. Dual mode-locked swept sources for SS-OCT

    NASA Astrophysics Data System (ADS)

    Stancu, Radu F.; Podoleanu, Adrian G.

    2016-03-01

    A novel dual-mode-locking mechanism was developed in order to tune an akinetic swept source (AKSS) based on dispersive cavity at a repetition rate close to, but slightly different from the inverse of the cavity roundtrip. Several optical source configurations emitting in the 1060 nm or 1550 nm wavelength region were developed, characterized and tested in OCT applications. For the 1550 nm swept source employing a Faraday rotating mirror in a dispersive cavity, sweeping rates in the range of MHz were achieved, from 782 kHz to up to 5 times this value, with proportional decrease in the tuning bandwidth. Linewidths smaller than 60 pm and output powers exceeding a few mW were measured. The 1060 nm swept source implemented was used to generate OCT images of a pressure sensitive adhesive.

  2. Accuracy of iodine quantification using dual energy CT in latest generation dual source and dual layer CT.

    PubMed

    Pelgrim, Gert Jan; van Hamersvelt, Robbert W; Willemink, Martin J; Schmidt, Bernhard T; Flohr, Thomas; Schilham, Arnold; Milles, Julien; Oudkerk, Matthijs; Leiner, Tim; Vliegenthart, Rozemarijn

    2017-09-01

    To determine the accuracy of iodine quantification with dual energy computed tomography (DECT) in two high-end CT systems with different spectral imaging techniques. Five tubes with different iodine concentrations (0, 5, 10, 15, 20 mg/ml) were analysed in an anthropomorphic thoracic phantom. Adding two phantom rings simulated increased patient size. For third-generation dual source CT (DSCT), tube voltage combinations of 150Sn and 70, 80, 90, 100 kVp were analysed. For dual layer CT (DLCT), 120 and 140 kVp were used. Scans were repeated three times. Median normalized values and interquartile ranges (IQRs) were calculated for all kVp settings and phantom sizes. Correlation between measured and known iodine concentrations was excellent for both systems (R = 0.999-1.000, p < 0.0001). For DSCT, median measurement errors ranged from -0.5% (IQR -2.0, 2.0%) at 150Sn/70 kVp and -2.3% (IQR -4.0, -0.1%) at 150Sn/80 kVp to -4.0% (IQR -6.0, -2.8%) at 150Sn/90 kVp. For DLCT, median measurement errors ranged from -3.3% (IQR -4.9, -1.5%) at 140 kVp to -4.6% (IQR -6.0, -3.6%) at 120 kVp. Larger phantom sizes increased variability of iodine measurements (p < 0.05). Iodine concentration can be accurately quantified with state-of-the-art DECT systems from two vendors. The lowest absolute errors were found for DSCT using the 150Sn/70 kVp or 150Sn/80 kVp combinations, which was slightly more accurate than 140 kVp in DLCT. • High-end CT scanners allow accurate iodine quantification using different DECT techniques. • Lowest measurement error was found in scans with largest photon energy separation. • Dual-source CT quantified iodine slightly more accurately than dual layer CT.

  3. The added diagnostic value of 64-row multidetector CT combined with contrast-enhanced US in the evaluation of hepatocellular nodule vascularity: implications in the diagnosis of malignancy in patients with liver cirrhosis.

    PubMed

    Quaia, Emilio; Alaimo, Valerio; Baratella, Elisa; Medeot, Alessandro; Midiri, Massimo; Cova, Maria Assunta

    2009-03-01

    The aim of this study was to assess the added diagnostic value of contrast-enhanced US (CEUS) combined with 64-row multidetector CT (CT) in the assessment of hepatocellular nodule vascularity in patients with liver cirrhosis. One hundred and six cirrhotic patients (68 male, 38 female; mean age +/- SD, 70 +/- 7 years) with 121 biopsy-proven hepatocellular nodules (72 hepatocellular carcinomas, 10 dysplastic and 15 regenerative nodules, 12 hemangiomas, and 12 other benignancies) detected during US surveillance were prospectively recruited. Each nodule was scanned by CEUS during the arterial (10-40 s), portal venous (45-90 s), and delayed sinusoidal phase (from 100 s after microbubble injection to microbubble disappearance). Nodule vascularity at CEUS, CT, and combined CEUS/CT was evaluated side-by-side by two independent blinded readers who classified nodules as benign or malignant according to reference diagnostic criteria. The combined assessment of CEUS/CT provided higher sensitivity (97%, both readers) than did separate assessment of CEUS (88% reader 1; 87% reader 2) and CT (74% reader 1; 71% reader 2; P < 0.05), while no change in specificity was provided by combined analysis. The combined assessment of hepatocellular nodule vascularity at CT and CEUS improved sensitivity in the diagnosis of malignancy in patients with liver cirrhosis.

  4. A millimeter wavelength radiation source using a dual grating resonator

    SciTech Connect

    Killoran, J.H.; Hacker, F.L.; Walsh, J.E. . Dept. of Physics)

    1994-10-01

    A novel means of producing coherent radiation by passing an electron through a dual-grating resonator is presented. The observed radiation is in accordance with the Smith-Purcell dispersion relation for a single grating. Feedback is provided by a second grating. Experiments carried out at beam energies from 30--55 KeV produced radiation at wavelengths from 6 to 0.75 mm. Power measurements were used to clarify the grating-beam interaction. Indications are that operation could be easily extended to shorter wavelengths to provide an inexpensive and compact radiation source in the far-infrared.

  5. Quantitative imaging of chemical composition using dual-energy, dual-source CT

    NASA Astrophysics Data System (ADS)

    Liu, Xin; Primak, Andrew N.; Yu, Lifeng; McCollough, Cynthia H.; Morin, Richard L.

    2008-03-01

    Dual-energy x-ray material decomposition has been proposed as a noninvasive quantitative imaging technique for more than 20 years. In this paper, we summarize previously developed dual-energy material decomposition methods and propose a simple yet accurate method for quantitatively measuring chemical composition in vivo. In order to take advantage of the newly developed dual-source CT, the proposed method is based upon post reconstruction (image space) data. Different from other post reconstruction methods, this method is designed to directly measure element composition (mass fraction) in a tissue by a simple table lookup procedure. The method has been tested in phantom studies and also applied to a clinical case. The results showed that this method is capable of accurately measuring elemental concentrations, such as iron in tissue, under low noise imaging conditions. The advantage of this method lies in its simplicity and fast processing times. We believe that this method can be applied clinically to measure the mass fraction of any chemical element in a two-material object, such as to quantify the iron overload in the liver (hemochromatosis). Further investigations on de-noising techniques, as well as clinical validation, are merited.

  6. Vertical-dual-source tunnel FETs with steeper subthreshold swing

    NASA Astrophysics Data System (ADS)

    Zhi, Jiang; Yiqi, Zhuang; Cong, Li; Ping, Wang; Yuqi, Liu

    2016-09-01

    In order to improve the drive current and subthreshold swing (SS), a novel vertical-dual-source tunneling field-effect transistor (VDSTFET) device is proposed in this paper. The influence of source height, channel length and channel thickness on the device are investigated through two-dimensional numerical simulations. Si-VDSTFET have greater tunneling area and thinner channel, showing an on-current as high as 1.24 μA at gate voltage of 0.8 V and drain voltage of 0.5 V, off-current of less than 0.1 fA, an improved average subthreshold swing of 14 mV/dec, and a minimum point slope of 4 mV/dec. Project supported by the National Natural Science Foundation of China (Nos. 61204092, 61574109).

  7. Dual-Frequency Coherence of Seismic Tremor and Source Properties

    NASA Astrophysics Data System (ADS)

    Dorman, L. M.; Schwartz, S. Y.; Clarke, D. L.

    2009-12-01

    Last fall Dorman and Schwartz reported discovery of a statistical signature (Dual-frequency coherence-DFC) which distinguishes nonvolcanic tremor from the usual microseismic noise. This was first observed in OBS data from the CRSEIZE experiment of 1999-2000 (DeShon and others, 2006), and later on land data from the Nicoya Peninsula. The tremor observed on OBSs was correlated with fluid flow through the seafloor (Brown and others, 2005). The observation of this signature on both land and OBS data indicates that it is a property of the source, rather than the path or the instrument or its environment. Possible causes include the fluid flow noise proposed by Julian (1994) and a repetitive stick-slip motion. Recent work has shown that nonvolcanic tremor accompanying slow slip in three different subduction zones, including northern Costa Rica, consists of swarms of low-frequency earthquakes that occur as stick-slip motion on the plate interface (Brown et al., 2008). Thus, both fluid flow and shear failure sources may be responsible for tremor generation. New work reveals that a Rössler attractor of the type studied by Julian produces a DFC similar to that of the tremor. Since the frequency of the oscillator is controlled by the physical properties of the source (fluid viscosity, channel dimension, flow velocity) this establishes a link between the seismically observable offset frequencies and one potential source mechanism.

  8. Initial experience of dual-energy lung perfusion CT using a dual-source CT system in children.

    PubMed

    Goo, Hyun Woo

    2010-09-01

    Initial experience of dual-source dual-energy (DE) lung perfusion CT in children is described. In addition to traditional identification of pulmonary emboli, the assessment of lung perfusion is technically feasible with dual-source DE CT in children with acceptable radiation dose. This article describes how to perform dual-source DE lung perfusion CT in children, including the optimization of intravenous injection method and CT dose parameters. How to produce weighted-average CT images for the assessment of pulmonary emboli and colour-coded perfusion maps for the assessment of regional lung perfusion is also detailed. Lung perfusion status can then be evaluated on perfusion maps by means of either qualitative or quantitative analysis. Potential advantages and disadvantages of this emerging CT technique compared to lung perfusion scintigraphy and cardiac MRI are discussed.

  9. Dual-source dual-power electrospinning and characteristics of multifunctional scaffolds for bone tissue engineering.

    PubMed

    Wang, Chong; Wang, Min

    2012-10-01

    Electrospun tissue engineering scaffolds are attractive due to their distinctive advantages over other types of scaffolds. As both osteoinductivity and osteoconductivity play crucial roles in bone tissue engineering, scaffolds possessing both properties are desirable. In this investigation, novel bicomponent scaffolds were constructed via dual-source dual-power electrospinning (DSDPES). One scaffold component was emulsion electrospun poly(D,L-lactic acid) (PDLLA) nanofibers containing recombinant human bone morphogenetic protein (rhBMP-2), and the other scaffold component was electrospun calcium phosphate (Ca-P) particle/poly(lactic-co-glycolic acid) (PLGA) nanocomposite fibers. The mass ratio of rhBMP-2/PDLLA fibers to Ca-P/PLGA fibers in bicomponent scaffolds could be controlled in the DSDPES process by adjusting the number of syringes used to supply solutions for electrospinning. Through process optimization, both types of fibers could be evenly distributed in bicomponent scaffolds. The structure and properties of each type of fibers in the scaffolds were studied. The morphological and structural properties and wettability of scaffolds were assessed. The effects of emulsion composition for rhBMP-2/PDLLA fibers and mass ratio of fibrous components in bicomponent scaffolds on in vitro release of rhBMP-2 from scaffolds were investigated. In vitro degradation of scaffolds was also studied by monitoring their morphological changes, weight losses and decreases in average molecular weight of fiber matrix polymers.

  10. Technical Note: Insertion of digital lesions in the projection domain for dual-source, dual-energy CT.

    PubMed

    Ferrero, Andrea; Chen, Baiyu; Li, Zhoubo; Yu, Lifeng; McCollough, Cynthia

    2017-05-01

    To compare algorithms performing material decomposition and classification in dual-energy CT, it is desirable to know the ground truth of the lesion to be analyzed in real patient data. In this work, we developed and validated a framework to insert digital lesions of arbitrary chemical composition into patient projection data acquired on a dual-source, dual-energy CT system. A model that takes into account beam-hardening effects was developed to predict the CT number of objects with known chemical composition. The model utilizes information about the x-ray energy spectra, the patient/phantom attenuation, and the x-ray detector energy response. The beam-hardening model was validated on samples of iodine (I) and calcium (Ca) for a second-generation dual-source, dual-energy CT scanner for all tube potentials available and a wide range of patient sizes. The seven most prevalent mineral components of renal stones were modeled and digital stones were created with CT numbers computed for each patient/phantom size and x-ray energy spectra using the developed beam-hardening model. Each digital stone was inserted in the dual-energy projection data of a water phantom scanned on a dual-source scanner and reconstructed with the routine algorithms in use in our practice. The geometry of the forward projection for dual-energy data was validated by comparing CT number accuracy and high-contrast resolution of simulated dual-energy CT data of the ACR phantom with experimentally acquired data. The beam-hardening model and forward projection method accurately predicted the CT number of I and Ca over a wide range of tube potentials and phantom sizes. The images reconstructed after the insertion of digital kidney stones were consistent with the images reconstructed from the scanner, and the CT number ratios for different kidney stone types were consistent with data in the literature. A sample application of the proposed tool was also demonstrated. A framework was developed and validated

  11. Dual energy CT with photon counting and dual source systems: comparative evaluation.

    PubMed

    Atak, Haluk; Shikhaliev, Polad M

    2015-12-07

    Recently, new dual energy (DE) computed tomography (CT) systems-dual source CT (DSCT) and photon counting CT (PCCT) have been introduced. Although these systems have the same clinical targets, they have major differences as they use dual and single kVp acquisitions and different x-ray detection and energy resolution concepts. The purpose of this study was theoretical and experimental comparisons of DSCT and PCCT. The DSCT Siemens Somatom Flash was modeled for simulation study. The PCCT had the same configuration as DSCT except it used a photon counting detector. The soft tissue phantoms with 20, 30, and 38 cm diameters included iodine, CaCO3, adipose, and water samples. The dose (air kerma) was 14 mGy for all studies. The low and high energy CT data were simulated at 80 kVp and 140 kVp for DSCT, and in 20-58 keV and 59-120 keV energy ranges for PCCT, respectively. The experiments used Somatom Flash DSCT system and PCCT system based on photon counting CdZnTe detector with 2  ×  256 pixel configuration and 1  ×  1 mm(2) pixels size. In simulated general CT images, PCCT provided higher contrast-to-noise ratio (CNR) than DSCT with 0.4/0.8 mm Sn filters. The PCCT with K-edge filter provided higher CNR than the PCCT with a Cu filter, and DSCT with 0.4 mm Sn filter provided higher CNR than the DSCT with a 0.8 mm Sn filter. In simulated DE subtracted images, CNR of the DSCT was comparable to the PCCT with a Cu filter. However, DE PCCT with Ho a K-edge filter provided 30-40% higher CNR than the DE DSCT with 0.4/0.8 mm Sn filters. The experimental PCCT provided higher CNR in general imaging compared to the DSCT. In experimental DE subtracted images, the DSCT provided higher CNR than the PCCT with a Cu filter. However, experimental CNR with DE PCCT with K-edge filter was 15% higher than in DE DSCT, which is less than 30-40% increase predicted by the simulation study. It is concluded that ideal PCCT can provide substantial advantages over ideal

  12. Dual energy CT with photon counting and dual source systems: comparative evaluation

    NASA Astrophysics Data System (ADS)

    Atak, Haluk; Shikhaliev, Polad M.

    2015-12-01

    Recently, new dual energy (DE) computed tomography (CT) systems—dual source CT (DSCT) and photon counting CT (PCCT) have been introduced. Although these systems have the same clinical targets, they have major differences as they use dual and single kVp acquisitions and different x-ray detection and energy resolution concepts. The purpose of this study was theoretical and experimental comparisons of DSCT and PCCT. The DSCT Siemens Somatom Flash was modeled for simulation study. The PCCT had the same configuration as DSCT except it used a photon counting detector. The soft tissue phantoms with 20, 30, and 38 cm diameters included iodine, CaCO3, adipose, and water samples. The dose (air kerma) was 14 mGy for all studies. The low and high energy CT data were simulated at 80 kVp and 140 kVp for DSCT, and in 20-58 keV and 59-120 keV energy ranges for PCCT, respectively. The experiments used Somatom Flash DSCT system and PCCT system based on photon counting CdZnTe detector with 2  ×  256 pixel configuration and 1  ×  1 mm2 pixels size. In simulated general CT images, PCCT provided higher contrast-to-noise ratio (CNR) than DSCT with 0.4/0.8 mm Sn filters. The PCCT with K-edge filter provided higher CNR than the PCCT with a Cu filter, and DSCT with 0.4 mm Sn filter provided higher CNR than the DSCT with a 0.8 mm Sn filter. In simulated DE subtracted images, CNR of the DSCT was comparable to the PCCT with a Cu filter. However, DE PCCT with Ho a K-edge filter provided 30-40% higher CNR than the DE DSCT with 0.4/0.8 mm Sn filters. The experimental PCCT provided higher CNR in general imaging compared to the DSCT. In experimental DE subtracted images, the DSCT provided higher CNR than the PCCT with a Cu filter. However, experimental CNR with DE PCCT with K-edge filter was 15% higher than in DE DSCT, which is less than 30-40% increase predicted by the simulation study. It is concluded that ideal PCCT can provide substantial advantages over ideal

  13. Physical analysis of breast cancer using dual-source computed tomography

    NASA Astrophysics Data System (ADS)

    Kim, H. J.; Lee, H. K.; Cho, J. H.

    2014-12-01

    This study was aimed to analyze various physical characteristics of breast cancer using dual-source computed tomography (CT). A phantom study and a clinical trial were performed in order and a 64-multidetector CT device was used for the examinations. In the phantom study, single-source (SS) CT was set up with a conventional scanning condition that is usually applied for breast CT examination and implementation was done at tube voltage of 120 kVp. Dual-source CT acquired images by irradiating X-ray sources with fast switching between two kilovoltage settings (80 and 140 kVp). After scanning, Hounsfield Unit (HU) values and radiation doses in a region of interest were measured and analyzed. In the clinical trial, the HU values were measured and analyzed after single-source computed tomography (SSCT) and dual-source CT in patients diagnosed with breast cancer. Also, the tumor size measured by dual-source CT was compared with the actual tumor size. The phantom study determined that the tumor region was especially measured by dual-source CT, while nylon fiber and specks region were especially measured by SSCT. The radiation dose was high with dual-source CT. The clinical trial showed a higher HU value of cancerous regions when scanned by dual-source CT compared with SSCT.

  14. Temporal resolution and motion artifacts in single-source and dual-source cardiac CT

    SciTech Connect

    Schoendube, Harald; Allmendinger, Thomas; Stierstorfer, Karl; Bruder, Herbert; Flohr, Thomas

    2013-03-15

    Purpose: The temporal resolution of a given image in cardiac computed tomography (CT) has so far mostly been determined from the amount of CT data employed for the reconstruction of that image. The purpose of this paper is to examine the applicability of such measures to the newly introduced modality of dual-source CT as well as to methods aiming to provide improved temporal resolution by means of an advanced image reconstruction algorithm. Methods: To provide a solid base for the examinations described in this paper, an extensive review of temporal resolution in conventional single-source CT is given first. Two different measures for assessing temporal resolution with respect to the amount of data involved are introduced, namely, either taking the full width at half maximum of the respective data weighting function (FWHM-TR) or the total width of the weighting function (total TR) as a base of the assessment. Image reconstruction using both a direct fan-beam filtered backprojection with Parker weighting as well as using a parallel-beam rebinning step are considered. The theory of assessing temporal resolution by means of the data involved is then extended to dual-source CT. Finally, three different advanced iterative reconstruction methods that all use the same input data are compared with respect to the resulting motion artifact level. For brevity and simplicity, the examinations are limited to two-dimensional data acquisition and reconstruction. However, all results and conclusions presented in this paper are also directly applicable to both circular and helical cone-beam CT. Results: While the concept of total TR can directly be applied to dual-source CT, the definition of the FWHM of a weighting function needs to be slightly extended to be applicable to this modality. The three different advanced iterative reconstruction methods examined in this paper result in significantly different images with respect to their motion artifact level, despite exactly the same

  15. DualSPHysics: Open-source parallel CFD solver based on Smoothed Particle Hydrodynamics (SPH)

    NASA Astrophysics Data System (ADS)

    Crespo, A. J. C.; Domínguez, J. M.; Rogers, B. D.; Gómez-Gesteira, M.; Longshaw, S.; Canelas, R.; Vacondio, R.; Barreiro, A.; García-Feal, O.

    2015-02-01

    DualSPHysics is a hardware accelerated Smoothed Particle Hydrodynamics code developed to solve free-surface flow problems. DualSPHysics is an open-source code developed and released under the terms of GNU General Public License (GPLv3). Along with the source code, a complete documentation that makes easy the compilation and execution of the source files is also distributed. The code has been shown to be efficient and reliable. The parallel power computing of Graphics Computing Units (GPUs) is used to accelerate DualSPHysics by up to two orders of magnitude compared to the performance of the serial version.

  16. Precision error in dual-photon absorptiometry related to source age

    SciTech Connect

    Ross, P.D.; Wasnich, R.D.; Vogel, J.M.

    1988-02-01

    An average, variable precision error of up to 6% related to source age was observed for dual-photon absorptiometry of the spine in a longitudinal study of bone mineral content involving 393 women. Application of a software correction for source decay compensated for only a portion of this error. The authors conclude that measurement of bone-loss rates using serial dual-photon bone mineral measurements must be interpreted with caution.

  17. Left Ventricular Diastolic Dysfunction Assessment with Dual-Source CT

    PubMed Central

    Wen, Zhaoying; Ma, Heng; Zhao, Ying; Fan, Zhanming; Zhang, Zhaoqi; Choi, Sang Il; Choe, Yeon Hyeon; Liu, Jiayi

    2015-01-01

    Purpose To assess the impact of left ventricular (LV) diastolic dysfunction on left atrial (LA) phasic volume and function using dual-source CT (DSCT) and to find a viable alternative prognostic parameter of CT for LV diastolic dysfunction through quantitative evaluation of LA phasic volume and function in patients with LV diastolic dysfunction. Materials and Methods Seventy-seven patients were examined using DSCT and Doppler echocardiography on the same day. Reservoir, conduit, and contractile function of LA were evaluated by measuring LA volume (LAV) during different cardiac phases and all parameters were normalized to body surface area (BSA). Patients were divided into four groups (normal, impaired relaxation, pseudonormal, and restrictive LV diastolic filling) according to echocardiographic findings. The LA phasic volume and function in different stages of LV diastolic function was compared using one-way ANOVA analysis. The correlations between indexed volume of LA (LAVi) and diastolic function in different stages of LV were evaluated using Spearman correlation analysis. Results LA ejection fraction (LAEF), LA contraction, reservoir, and conduit function in patients in impaired relaxation group were not different from those in the normal group, but they were lower in patients in the pseudonormal and restrictive LV diastolic dysfunction groups (P < 0.05). For LA conduit function, there were no significant differences between the patients in the pseudonormal group and restrictive filling group (P = 0.195). There was a strong correlation between the indexed maximal left atrial volume (LAVmax, r = 0.85, P < 0.001), minimal left atrial volume (LAVmin, r = 0.91, P < 0.001), left atrial volume at the onset of P wave (LAVp, r = 0.84, P < 0.001), and different stages of LV diastolic function. The LAVi increased as the severity of LV diastolic dysfunction increased. Conclusions LA remodeling takes place in patients with LV diastolic dysfunction. At the same time, LA

  18. Conditional Reasoning in Context: A Dual-Source Model of Probabilistic Inference

    ERIC Educational Resources Information Center

    Klauer, Karl Christoph; Beller, Sieghard; Hutter, Mandy

    2010-01-01

    A dual-source model of probabilistic conditional inference is proposed. According to the model, inferences are based on 2 sources of evidence: logical form and prior knowledge. Logical form is a decontextualized source of evidence, whereas prior knowledge is activated by the contents of the conditional rule. In Experiments 1 to 3, manipulations of…

  19. Sources of Role Strain among Dual-Career Couples.

    ERIC Educational Resources Information Center

    Bird, Gloria W.; Ford, Rachel

    1985-01-01

    Examines the extent of role strain among husbands and wives in 69 dual-career couples. Results indicated that, for wives, number of children and importance of the parental role were significant predictors of role strain. For husbands, role strain was related to age of the youngest child and the extent to which child-care tasks were shared.…

  20. Radiation Optimized Dual-source Dual-energy Computed Tomography Pulmonary Angiography: Intra-individual and Inter-individual Comparison.

    PubMed

    Li, Xie; Chen, Guo Zhong; Zhao, Yan E; Schoepf, U Joseph; Albrecht, Moritz H; Bickford, Matthew W; Gu, Hai Feng; Zhang, Long Jiang; Lu, Guang Ming

    2017-01-01

    This study aimed to intra-individually and inter-individually compare image quality, radiation dose, and diagnostic accuracy of dual-source dual-energy computed tomography pulmonary angiography (CTPA) protocols in patients with suspected pulmonary embolism (PE). Thirty-three patients with suspected PE underwent initial and follow-up dual-energy CTPA at 80/Sn140 kVp (group A) or 100/Sn140 kVp (group B), which were assigned based on tube voltages. Subjective and objective CTPA image quality and lung perfusion map image quality were evaluated. Diagnostic accuracies of CTPA and perfusion maps were assessed by two radiologists independently. Effective dose (ED) was calculated and compared. Mean computed tomography (CT) values of pulmonary arteries were higher in group A than group B (P = .006). There was no difference in signal-to-noise ratio and contrast-to-noise ratio between the two groups (both P > .05). Interobserver agreement for evaluating subjective image quality of CTPA and color-coded perfusion images was either good (κ = 0.784) or excellent (κ = 0.887). Perfusion defect scores and diagnostic accuracy of CTPA showed no difference between both groups (both P > .05). Effective dose of group A was reduced by 45.8% compared to group B (P < .001). Second-generation dual-source dual-energy CTPA with 80/Sn140 kVp allows for sufficient image quality and diagnostic accuracy for detecting PE while substantially reducing radiation dose. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  1. Simultaneous 1310/1550 dual-band swept laser source and fiber-based dual-band common-path swept source optical coherence tomography

    NASA Astrophysics Data System (ADS)

    Mao, Youxin; Chang, Shoude; Murdock, Erroll; Flueraru, Costel

    2011-08-01

    A simultaneous two wavelength band swept laser source and a fiber-based dual-band common-path swept source optical coherence tomography is reported. Simultaneous 1310/1550 dual-wavelength tuning is performed by using two fiber-ring cavities with corresponding optical semiconductor amplifier as their gain mediums and two narrowband optical filters with a single dual-window polygonal scanner. Measured average output powers of 60 mW and 27 mW have been achieved for 1310 and 1550 nm bands, respectively, while the two wavelengths were swept simultaneously from 1227 nm to 1387 nm for 1310 nm band and from 1519 nm to 1581 nm for 1550 nm band at an A-scan rate of 65 kHz. A broadband 1310/1550 wavelength-division multiplexing is used for coupling two wavelengths into a common-path single-mode GRIN-lensed fiber probe to form a dual-band common-path swept-source optical coherence tomography. Simultaneous OCT imaging at 1310 and 1550 nm is achieved by using a depth ratio correction method. This technique allows potentially for in vivo endoscopic high-speed functional OCT imaging with high quality spectroscopic contrast with low computational costs. On the other hand, the common path configuration is able to reject common mode noise and potentially implement high stability quantitative phase measurements.

  2. DUAL HEATED ION SOURCE STRUCTURE HAVING ARC SHIFTING MEANS

    DOEpatents

    Lawrence, E.O.

    1959-04-14

    An ion source is presented for calutrons, particularly an electrode arrangement for the ion generator of a calutron ion source. The ion source arc chamber is heated and an exit opening with thermally conductive plates defines the margins of the opening. These plates are electrically insulated from the body of the ion source and are connected to a suitable source of voltage to serve as electrodes for shaping the ion beam egressing from the arc chamber.

  3. Fluorescent Heterogeneities in Turbid Media: Limits for Detection With Dual-Interfering Sources Excitation

    DTIC Science & Technology

    2001-10-25

    J.Opt.Soc.Am.A 11, 2727-2741 (1994). [19] T.Desmettre, J.Devoiselle & S.Mordon, “Fluorescent properties and metabolic features of Indocyanine Green (ICG...and phase. The set-up configurations and the optical values used matched the typical case of breast optical mammography with the use of Indocyanine ... Green (ICG). An extensive comparison between single and dual source configurations was carried out. More precisely we compared single and dual

  4. Extracting atomic numbers and electron densities from a dual source dual energy CT scanner: experiments and a simulation model.

    PubMed

    Landry, Guillaume; Reniers, Brigitte; Granton, Patrick Vincent; van Rooijen, Bart; Beaulieu, Luc; Wildberger, Joachim E; Verhaegen, Frank

    2011-09-01

    Dual energy CT (DECT) imaging can provide both the electron density ρ(e) and effective atomic number Z(eff), thus facilitating tissue type identification. This paper investigates the accuracy of a dual source DECT scanner by means of measurements and simulations. Previous simulation work suggested improved Monte Carlo dose calculation accuracy when compared to single energy CT for low energy photon brachytherapy, but lacked validation. As such, we aim to validate our DECT simulation model in this work. A cylindrical phantom containing tissue mimicking inserts was scanned with a second generation dual source scanner (SOMATOM Definition FLASH) to obtain Z(eff) and ρ(e). A model of the scanner was designed in ImaSim, a CT simulation program, and was used to simulate the experiment. Accuracy of measured Z(eff) (labelled Z) was found to vary from -10% to 10% from low to high Z tissue substitutes while the accuracy on ρ(e) from DECT was about 2.5%. Our simulation reproduced the experiments within ±5% for both Z and ρ(e). A clinical DECT scanner was able to extract Z and ρ(e) of tissue substitutes. Our simulation tool replicates the experiments within a reasonable accuracy. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  5. Spatial Distribution of Iron Within the Normal Human Liver Using Dual-Source Dual-Energy CT Imaging.

    PubMed

    Abadia, Andres F; Grant, Katharine L; Carey, Kathleen E; Bolch, Wesley E; Morin, Richard L

    2017-05-29

    Explore the potential of dual-source dual-energy (DSDE) computed tomography (CT) to retrospectively analyze the uniformity of iron distribution and establish iron concentration ranges and distribution patterns found in healthy livers. Ten mixtures consisting of an iron nitrate solution and deionized water were prepared in test tubes and scanned using a DSDE 128-slice CT system. Iron images were derived from a 3-material decomposition algorithm (optimized for the quantification of iron). A conversion factor (mg Fe/mL per Hounsfield unit) was calculated from this phantom study as the quotient of known tube concentrations and their corresponding CT values. Retrospective analysis was performed of patients who had undergone DSDE imaging for renal stones. Thirty-seven patients with normal liver function were randomly selected (mean age, 52.5 years). The examinations were processed for iron concentration. Multiple regions of interest were analyzed, and iron concentration (mg Fe/mL) and distribution was reported. The mean conversion factor obtained from the phantom study was 0.15 mg Fe/mL per Hounsfield unit. Whole-liver mean iron concentrations yielded a range of 0.0 to 2.91 mg Fe/mL, with 94.6% (35/37) of the patients exhibiting mean concentrations below 1.0 mg Fe/mL. The most important finding was that iron concentration was not uniform and patients exhibited regionally high concentrations (36/37). These regions of higher concentration were observed to be dominant in the middle-to-upper part of the liver (75%), medially (72.2%), and anteriorly (83.3%). Dual-source dual-energy CT can be used to assess the uniformity of iron distribution in healthy subjects. Applying similar techniques to unhealthy livers, future research may focus on the impact of hepatic iron content and distribution for noninvasive assessment in diseased subjects.

  6. [Research on night visibility estimation method based on image features of dual light sources].

    PubMed

    Dai, Pang-Da; Zhang, Yu-Jun; Lu, Chang-Hua; Zhou, Yi; Liu, Jing; Xiao, Xue; Liu, Wen-Qing; Wang, Jing-Li

    2014-01-01

    Haze, rain and snow bring a lot of inconvenience in our daily life, especially produce serious potential safety hazard for night transport. In the present paper the authors propose the vision-based dual light sources visibility method to estimate night visibility. This method is significantly advantaged with wide range, high precision and low cost, and has a good robustness in many kinds of weather conditions. Firstly, the authors give the basic visibility estimation model under the atmosphere multiple scattering theory. Secondly, the authors propose the dual light sources method to remove the luminance fluctuations of light sources and the atmosphere light effect, and formulize the algorithm to accurately gain information of light sources from the dual light sources image. At last, the authors design the dual light sources system and conduct a long time experiments under various atmosphere conditions. The experiments show that, with the baseline of 35 m, the visibility range is up to 15 000 m, and relative error is below 20%. This method and system can satisfy the demand of meteorological department and transport agency.

  7. Source book for planning nuclear dual-purpose electric/distillation desalination plants

    SciTech Connect

    Reed, S.A.

    1981-02-01

    A source book on nuclear dual-purpose electric/distillation desalination plants was prepared to assist government and other planners in preparing broad evaluations of proposed applications of dual-purpose plants. The document is divided into five major sections. Section 1 presents general discussions relating to the benefits of dual-purpose plants, and spectrum for water-to-power ratios. Section 2 presents information on commercial nuclear plants manufactured by US manufacturers. Section 3 gives information on distillation desalting processes and equipment. Section 4 presents a discussion on feedwater pretreatment and scale control. Section 5 deals with methods for coupling the distillation and electrical generating plants to operate in the dual mode.

  8. Truncus arteriosus: Diagnosis with dual-source computed tomography angiography and low radiation dose

    PubMed Central

    Koplay, Mustafa; Cimen, Derya; Sivri, Mesut; Güvenc, Osman; Arslan, Derya; Nayman, Alaaddin; Oran, Bulent

    2014-01-01

    Truncus arteriosus is an uncommon congenital cardiac abnormality which is characterized by a single arterial trunk origin from the heart that supplies both the systemic, pulmonary and coronary circulation. We present a preterm newborn female patient with type 2 truncusarteriosus, left superior vena cava and aberrant subclavian artery diagnosed with low dose dual-source cardiac computed tomography (CT). We discuss that low dose dual-source cardiac CT has more advantages than other imaging methods and it is an important modality for assessment of patients with conotruncal anomalies such as truncusarteriosus. PMID:25431644

  9. Diffuse optical tomography using dual-interfering source

    NASA Astrophysics Data System (ADS)

    Chen, Yu; Mu, Chenpeng; Intes, Xavier; Chance, Britton

    2002-04-01

    A frequency domain heterodyne system for recording the amplitude and phase of diffuse photon density wave (DPDW) is described here. We demonstrated experimentally the possibility of tomographic image reconstruction using a pair of out-of-phase sources. Both iterative method (SIRT) and subspace technique (SVD) have been used to address the inverse problem. The image quality with respect to the number of iterations and regularization numbers is discussed. Further investigations including the relationship between several parameters (such as modulation frequency, the source pair separation and the number of source and detectors) and the image quality are also discussed.

  10. Signal-to-noise analysis for detection sensitivity of small absorbing heterogeneity in turbid media with single-source and dual-interfering-source.

    PubMed

    Chen, Y; Mu, C; Intes, X; Chance, B

    2001-08-13

    Previous studies have suggested that the phased-array detection can achieve high sensitivity in detecting and localizing inhomogeneities embedded in turbid media by illuminating with dual interfering sources. In this paper, we analyze the sensitivity of single-source and dual-interfering-source (phased array) systems with signal-to-noise ratio criteria. Analytical solutions are presented to investigate the sensitivity of detection using different degrees of absorption perturbation by varying the size and contrast of the object under similar configurations for single- and dual-source systems. The results suggest that dual-source configuration can provide higher detection sensitivity. The relation between the amplitude and phase signals for both systems is also analyzed using a vector model. The results can be helpful for optimizing the experimental design by combining the advantages of both single- and dual-source systems in object detection and localization.

  11. Dorsal column steerability with dual parallel leads using dedicated power sources: a computational model.

    PubMed

    Lee, Dongchul; Gillespie, Ewan; Bradley, Kerry

    2011-02-10

    In spinal cord stimulation (SCS), concordance of stimulation-induced paresthesia over painful body regions is a necessary condition for therapeutic efficacy. Since patient pain patterns can be unique, a common stimulation configuration is the placement of two leads in parallel in the dorsal epidural space. This construct provides flexibility in steering stimulation current mediolaterally over the dorsal column to achieve better pain-paresthesia overlap. Using a mathematical model with an accurate fiber diameter distribution, we studied the ability of dual parallel leads to steer stimulation between adjacent contacts on dual parallel leads using (1) a single source system, and (2) a multi-source system, with a dedicated current source for each contact. The volume conductor model of a low-thoracic spinal cord with epidurally-positioned dual parallel (2 mm separation) percutaneous leads was first created, and the electric field was calculated using ANSYS, a finite element modeling tool. The activating function for 10 um fibers was computed as the second difference of the extracellular potential along the nodes of Ranvier on the nerve fibers in the dorsal column. The volume of activation (VOA) and the central point of the VOA were computed using a predetermined threshold of the activating function. The model compared the field steering results with single source versus dedicated power source systems on dual 8-contact stimulation leads. The model predicted that the multi-source system can target more central points of stimulation on the dorsal column than a single source system (100 vs. 3) and the mean steering step for mediolateral steering is 0.02 mm for multi-source systems vs 1 mm for single source systems, a 50-fold improvement. The ability to center stimulation regions in the dorsal column with high resolution may allow for better optimization of paresthesia-pain overlap in patients.

  12. Dorsal Column Steerability with Dual Parallel Leads using Dedicated Power Sources: A Computational Model

    PubMed Central

    Lee, Dongchul; Gillespie, Ewan; Bradley, Kerry

    2011-01-01

    In spinal cord stimulation (SCS), concordance of stimulation-induced paresthesia over painful body regions is a necessary condition for therapeutic efficacy. Since patient pain patterns can be unique, a common stimulation configuration is the placement of two leads in parallel in the dorsal epidural space. This construct provides flexibility in steering stimulation current mediolaterally over the dorsal column to achieve better pain-paresthesia overlap. Using a mathematical model with an accurate fiber diameter distribution, we studied the ability of dual parallel leads to steer stimulation between adjacent contacts on dual parallel leads using (1) a single source system, and (2) a multi-source system, with a dedicated current source for each contact. The volume conductor model of a low-thoracic spinal cord with epidurally-positioned dual parallel (2 mm separation) percutaneous leads was first created, and the electric field was calculated using ANSYS, a finite element modeling tool. The activating function for 10 um fibers was computed as the second difference of the extracellular potential along the nodes of Ranvier on the nerve fibers in the dorsal column. The volume of activation (VOA) and the central point of the VOA were computed using a predetermined threshold of the activating function. The model compared the field steering results with single source versus dedicated power source systems on dual 8-contact stimulation leads. The model predicted that the multi-source system can target more central points of stimulation on the dorsal column than a single source system (100 vs. 3) and the mean steering step for mediolateral steering is 0.02 mm for multi-source systems vs 1 mm for single source systems, a 50-fold improvement. The ability to center stimulation regions in the dorsal column with high resolution may allow for better optimization of paresthesia-pain overlap in patients. PMID:21339729

  13. Feasibility of dual-source cardiac CT angiography with high-pitch scan protocols.

    PubMed

    Hausleiter, Jörg; Bischoff, Bernhard; Hein, Franziska; Meyer, Tanja; Hadamitzky, Martin; Thierfelder, Carsten; Allmendinger, Thomas; Flohr, Thomas G; Schömig, Albert; Martinoff, Stefan

    2009-01-01

    Cardiac CT angiography (CCTA) has become a frequently used diagnostic tool in clinical practice, but concern remains about the radiation exposure. Because of the second x-ray acquisition system, dual-source CT systems might allow for high-pitch CT data acquisition and thus for examination of the whole heart during a single heart beat, with the potential for radiation dose reduction. We assessed the feasibility of a high-pitch scan mode with a dual-source CT system. High-pitch modes were used in patients undergoing CCTA with a dual-source CT system. Diagnostic image quality for cardiac structures and coronary arteries was assessed. Radiation dose was estimated from the scanner-generated dose-length product (DLP). CCTA was performed in 14 patients during a single heart beat applying a pitch value of 3.4. Mean heart rate during examination was 56.4+/-8.1 beats/min. Diagnostic image quality for the assessment of larger cardiac structures was obtained in all patients, whereas diagnostic image quality could be achieved in 82% of all coronary segments. With a mean DLP of 145+/-47 mGy x cm, the resulting estimated radiation dose was 2.0+/-0.7 mSv. This proof-of-concept study shows the ability of dual-source CT scanners to scan the whole heart during one single heart beat at low radiation dose.

  14. Dual color x-rays from Thomson or Compton sources

    NASA Astrophysics Data System (ADS)

    Petrillo, V.; Bacci, A.; Curatolo, C.; Ferrario, M.; Maroli, C.; Rau, J. V.; Ronsivalle, C.; Serafini, L.; Vaccarezza, C.; Venturelli, M.

    2015-05-01

    We analyze the possibility of producing two color X or γ radiation by Thomson/Compton back-scattering between a high intensity laser pulse and a two-energy level electron beam, constituted by a couple of beamlets separated in time and/or energy obtained by a photoinjector with comb laser techniques and linac velocity bunching. The parameters of the Thomson source at SPARC_LAB have been simulated, proposing a set of values for a realistic experiments.

  15. Dual color x rays from Thomson or Compton sources

    NASA Astrophysics Data System (ADS)

    Petrillo, V.; Bacci, A.; Curatolo, C.; Ferrario, M.; Gatti, G.; Maroli, C.; Rau, J. V.; Ronsivalle, C.; Serafini, L.; Vaccarezza, C.; Venturelli, M.

    2014-02-01

    We analyze the possibility of producing two-color x or γ radiation by Thomson/Compton backscattering between a high intensity laser pulse and a two-energy level electron beam, constituted by a couple of beamlets separated in time and/or energy obtained by a photoinjector with comb laser techniques and linac velocity bunching. The parameters of the Thomson source at SPARC_LAB have been simulated, proposing a set of realistic experiments.

  16. On-chip, self-detected terahertz dual-comb source

    SciTech Connect

    Rösch, Markus Scalari, Giacomo Villares, Gustavo; Bosco, Lorenzo; Beck, Mattias; Faist, Jérôme

    2016-04-25

    We present a directly generated on-chip dual-comb source at terahertz (THz) frequencies. The multi-heterodyne beating signal of two free-running THz quantum cascade laser frequency combs is measured electrically using one of the combs as a detector, fully exploiting the unique characteristics of quantum cascade active regions. Up to 30 modes can be detected corresponding to a spectral bandwidth of 630 GHz, being the available bandwidth of the dual comb configuration. The multi-heterodyne signal is used to investigate the equidistance of the comb modes showing an accuracy of 10{sup −12} at the carrier frequency of 2.5 THz.

  17. Diagnostic Value of Dual-Source Computerized Tomography Combined with Perfusion Imaging for Peripheral Pulmonary Embolism

    PubMed Central

    Mao, Xijin; Wang, Shanshan; Jiang, Xingyue; Zhang, Lin; Xu, Wenjian

    2016-01-01

    Background Pulmonary embolism has become the third most common cardiovascular disease, which can seriously harm human health. Objectives To investigate the diagnostic value of dual-source computerized tomography (CT) and perfusion imaging for peripheral pulmonary embolism. Patients and Methods Thirty-two patients with suspected pulmonary embolism underwent dual-source CT exams. To compare the ability of pulmonary embolism detection software (PED) with CT pulmonary angiography (CTPA) in determining the presence, numbers, and locations of pulmonary emboli, the subsequent images were reviewed by two radiologists using both imaging modalities. Also, the diagnostic consistency between PED and CTPA images and dual-energy pulmonary perfusion imaging (DEPI) for segmental pulmonary embolism was compared. Results CTPA images revealed 50 (7.81%) segmental and 56 (4.38%) sub-segmental pulmonary embolisms, while the PED images showed 68 (10.63%) segmental and 94 (7.34%) sub-segmental pulmonary embolisms. Thus, the detection rate on PED images for peripheral pulmonary embolism was significantly higher than that of the CTPA images (P < 0.05). There was good consistency for diagnosing segmental pulmonary embolism between PED and CTPA and DEPI (kappa = 0.85). The sensitivity and specificity of DEPI images for the diagnosis of pulmonary embolism were 91.7% and 97.5%, respectively. Conclusion PED software of dual-source CT combined with perfusion imaging can significantly improve the detection rate of peripheral pulmonary embolism. PMID:27703656

  18. Optimization of energy level for coronary angiography with dual-energy and dual-source computed tomography.

    PubMed

    Okayama, Satoshi; Seno, Ayako; Soeda, Tsunenari; Takami, Yasuhiro; Kawakami, Rika; Somekawa, Satoshi; Ishigami, Ken-Ichi; Takeda, Yukiji; Kawata, Hiroyuki; Horii, Manabu; Uemura, Shiro; Saito, Yoshihiko

    2012-04-01

    Dual-energy computed tomography (DE-CT) uses polyenergetic X-rays at 100- and 140-kVp tube energy, and generates 120-kVp composite images that are referred to as polyenergetic images (PEIs). Moreover, DE-CT can produce monoenergetic images (MEIs) at any effective energy level. We evaluated whether the image quality of coronary angiography is improved by optimizing the energy levels of DE-CT. We retrospectively evaluated data sets obtained from 24 consecutive patients using cardiac DE-CT at 100- and 140-kVp tube energy with a dual-source scanner. Signal-to-noise ratios (SNRs) were evaluated in the left ascending coronary artery in PEIs, and in MEIs reconstructed at 40, 50, 60, 70, 80, 90, 100, 130, 160 and 190 keV. Energy levels of 100, 120 and 140 kVp generated the highest SNRs in PEIs from 10, 12 and 2 patients, respectively, at 60, 70 and 80 keV in MEIs from 2, 10 and 10 patients, respectively, and at 90 and 100 keV in those from one patient each. Optimization of the energy level for each patient increased the SNR by 16.6% in PEIs (P < 0.0001) and by 18.2% in MEIs (P < 0.05), compared with 120-kVp composite images. The image quality of coronary angiography using DE-CT can be improved by optimizing the energy level for individual patients.

  19. Effect of Third-generation Dual-source CT Technology on Image Quality of Low-dose Chest CT.

    PubMed

    Sui, Xin; Xu, Xiaoli; Song, Lan; DU, Qianni; Wang, Xiao; Jing, Zhengyu; Song, Wei

    2017-02-20

    Objective To evaluate the image quality and radiation dose of third-generation dual-source CT with tin filtration for spectral shaping and iterative reconstructions.Methods Thirty-five patients underwent low-dose CT (LDCT) for lung cancer screening on second-generation dual-source CT and follow-ups on third-generation dual-source CT. Image quality and radiation dose were compared between the two examinations.ResultsThe radiation dose of third-generation dual-source CT [dose-length product (DLP)(49.7±18.2)mGy·cm, effective dose (ED)(0.73±0.26)mSv] was lower than second-generation dual-source CT [DLP (86.37±13.44) mGy·cm, ED(1.20±0.42)mSv](t=6.01, P=0.000;t=6.57, P=0.000). The objective image noise of second-generation dual-source CT [(25.7±2.9)HU] was higher than that of third-generation dual-soure CT[(18.6±4.2)HU](t=5.24,P=0.000).The subjective image noise of second-generation dual-source CT [(4.60±0.49)scores] was significantly lower than that of third-generation dual-source CT [(4.80±0.40)scores] (t=4.15, P=0.000). Conclusion Chest CT for the detection of pulmonary nodules can be performed with third-generation dual-source CT that produces high image quality and low radiation dose when using a stellar infinity detector with spectral shaping.

  20. Dose performance of a 64-channel dual-source CT scanner.

    PubMed

    McCollough, Cynthia H; Primak, Andrew N; Saba, Osama; Bruder, Herbert; Stierstorfer, Karl; Raupach, Rainer; Suess, Christoph; Schmidt, Bernhard; Ohnesorge, Bernd M; Flohr, Thomas G

    2007-06-01

    To prospectively compare the dose performance of a 64-channel multi-detector row computed tomographic (CT) scanner and a 64-channel dual-source CT scanner from the same manufacturer. To minimize dose in the cardiac (dual-source) mode, the evaluated dual-source CT system uses a cardiac beam-shaping filter, three-dimensional adaptive noise reduction, heart rate-dependent pitch, and electrocardiographically based modulation of the tube current. Weighted CT dose index per 100 mAs was measured for the head, body, and cardiac beam-shaping filters. Kerma-length product was measured in the spiral cardiac mode at four pitch values and three electrocardiographic modulation temporal windows. Noise was measured in an anthropomorphic phantom. Data were compared with data from a 64-channel multi-detector row CT scanner. For the multi-detector row and dual-source CT systems, respectively, weighted CT dose index per 100 mAs was 14.2 and 12.2 mGy (head CT), 6.8 and 6.4 mGy (body CT), and 6.8 and 5.3 mGy (cardiac CT). In the spiral cardiac mode (no electrocardiographically based tube current modulation, 0.2 pitch), equivalent noise occurred at volume CT dose index values of 23.7 and 35.0 mGy (coronary artery calcium CT) and 58.9 and 61.2 mGy (coronary CT angiography) for multi-detector row CT and dual-source CT, respectively. The use of heart rate-dependent pitch values reduced volume CT dose index to 46.2 mGy (0.265 pitch), 34.0 mGy (0.36 pitch), and 26.6 mGy (0.46 pitch) compared with 61.2 mGy for 0.2 pitch. The use of electrocardiographically based tube current-modulation and temporal windows of 110, 210, and 310 msec further reduced volume CT dose index to 9.1-25.1 mGy, dependent on the heart rate. For electrocardiographically gated coronary CT angiography, image noise equivalent to that of multi-detector row CT can be achieved with dual-source CT at doses comparable to or up to a factor of two lower than the doses at multi-detector row CT, depending on heart rate of the patient

  1. Attenuation-based characterization of coronary atherosclerotic plaque: comparison of dual source and dual energy CT with single-source CT and histopathology.

    PubMed

    Henzler, Thomas; Porubsky, Stefan; Kayed, Hany; Harder, Nils; Krissak, U Radko; Meyer, Mathias; Sueselbeck, Tim; Marx, Alexander; Michaely, Henrik; Schoepf, U Joseph; Schoenberg, Stefan O; Fink, Christian

    2011-10-01

    To compare different CT acquisition techniques regarding for attenuation-based characterization of coronary atherosclerotic plaques using histopathology as the standard of reference. In a post mortem study 17 human hearts were studied with dual-source CT (DSCT) and dual energy CT (DECT) mode on a DSCT as well as with 16-slice single-source CT (SSCT). At autopsy, atherosclerotic lesions were cut at 5 μm sections. Histopathologic classification of the plaques according to the American Heart Association (AHA) criteria was performed by two pathologists. Attenuation values of all plaques were measured in DSCT, DECT and SSCT studies, respectively and classified based on attenuation according to modified AHA criteria. 58 coronary plaques were identified at autopsy. Regardless of the CT technique only 52/58 plaques were found at CT (sensitivity=89.6%). There was no significant difference between the mean attenuation values of different plaque types between DSCT, DECT, and SSCT: type IV: 11HU/8HU/19HU; type Va: 44HU/45HU/52HU; type Vb: 1088HU/966HU/1079HU). The sensitivity for correct classification varied depending on the plaque type (type II=0%, type III=0%, type IV=43%, type Va=58%, Vb=97%). Independent of the used acquisition technique, SSCT, DSCT and DECT show similar results for attenuation-based characterization of atherosclerotic coronary plaques. Copyright © 2010. Published by Elsevier Ireland Ltd.

  2. Estimation of effective brain connectivity with dual Kalman filter and EEG source localization methods.

    PubMed

    Rajabioun, Mehdi; Nasrabadi, Ali Motie; Shamsollahi, Mohammad Bagher

    2017-08-29

    Effective connectivity is one of the most important considerations in brain functional mapping via EEG. It demonstrates the effects of a particular active brain region on others. In this paper, a new method is proposed which is based on dual Kalman filter. In this method, firstly by using a brain active localization method (standardized low resolution brain electromagnetic tomography) and applying it to EEG signal, active regions are extracted, and appropriate time model (multivariate autoregressive model) is fitted to extracted brain active sources for evaluating the activity and time dependence between sources. Then, dual Kalman filter is used to estimate model parameters or effective connectivity between active regions. The advantage of this method is the estimation of different brain parts activity simultaneously with the calculation of effective connectivity between active regions. By combining dual Kalman filter with brain source localization methods, in addition to the connectivity estimation between parts, source activity is updated during the time. The proposed method performance has been evaluated firstly by applying it to simulated EEG signals with interacting connectivity simulation between active parts. Noisy simulated signals with different signal to noise ratios are used for evaluating method sensitivity to noise and comparing proposed method performance with other methods. Then the method is applied to real signals and the estimation error during a sweeping window is calculated. By comparing proposed method results in different simulation (simulated and real signals), proposed method gives acceptable results with least mean square error in noisy or real conditions.

  3. Dual-source mass spectrometer with MALDI-LIT-ESI configuration.

    PubMed

    Smith, Scott A; Blake, Thomas A; Ifa, Demian R; Cooks, R Graham; Ouyang, Zheng

    2007-02-01

    A novel linear ion trap (LIT) mass spectrometer with dual matrix-assisted laser desorption/ionization (MALDI) and electrospray ionization (ESI) ionization sources has been built in the MALDI-LIT-ESI configuration. The design features two independent ion source/ion optical channels connected to opposite ends of a single mass analyzer. The instrument consists of a commercial MALDI-LIT instrument modified by the addition of a home-built vacuum manifold, ion optical system, control electronics, and programming necessary to couple an atmospheric pressure interface to the commercial instrument. In addition to the added ESI functionality, the capabilities of the system also include simultaneous dual-channel ion introduction and analysis and high-duty cycle electronic switching (<1 s) between ion channels. Analytical and ion chemical applications of the dual-source system are explored. One analytical application is the enhanced protein sequence coverage achieved when using both ESI and MALDI to examine a tryptic digest of a six-protein mixture. The differences in the efficiency with which peptides in a mixture are ionized by the two methods give improved sequence coverage when both are applied. Other analytical applications include the use of the ions from one source as intensity or mass standards for the analyte ions from the other. An ion chemistry application involves the use of energy-resolved tandem mass spectrometry (MS/MS) to seek evidence for the generation of isomeric ions from a particular compound using the two ionization methods. A high level of agreement was achieved between the MS/MS spectra recorded under a variety of conditions after ESI and MALDI ionization; this provides evidence of the reproducibility and internal consistency of data from the dual source instrument. However, each of the peptides examined generated identical populations of structures in the two ionization methods under our conditions which are interpreted as involving slow cooling into

  4. Bicomponent fibrous scaffolds made through dual-source dual-power electrospinning: Dual delivery of rhBMP-2 and Ca-P nanoparticles and enhanced biological performances.

    PubMed

    Wang, Chong; Lu, William Weijia; Wang, Min

    2017-08-01

    Electrospun scaffolds incorporated with both calcium phosphates (Ca-P) and bone morphogenetic protein-2 (BMP-2) have been used for bone tissue regeneration. However, in most cases BMP-2 and Ca-P were simply mixed and loaded in a monolithic structure, risking low BMP-2 loading level, reduced BMP-2 biological activity, uncontrolled BMP-2 release and inhomogeneous Ca-P distribution. In this investigation, novel bicomponent scaffolds having evenly distributed rhBMP-2-containing fibers and Ca-P nanoparticle-containing fibers were made using an established dual-source dual-power electrospinning technique with the assistance of emulsion electrospinning and blend electrospinning. The release behavior of rhBMP-2 and Ca(2+) ions could be separately tuned and the released rhBMP-2 retained a 68% level for biological activity. MC3T3-E1 cells showed high viability and normal morphology on scaffolds. Compared to monocomponent scaffolds, enhanced cell proliferation, alkaline phosphatase activity, cell mineralization, and gene expression of osteogenic markers were achieved for bicomponent scaffolds due to the synergistic effect of rhBMP-2 and Ca-P nanoparticles. Bicomponent scaffolds with a double mass elicited further enhanced cell adhesion, spreading, proliferation, and osteogenic differentiation. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 105A: 2199-2209, 2017. © 2017 Wiley Periodicals, Inc.

  5. A new coaxial high power microwave source based on dual beams

    NASA Astrophysics Data System (ADS)

    Li, Yangmei; Zhang, Xiaoping; Qi, Zumin; Dang, Fangchao; Qian, Baoliang

    2014-05-01

    We present a new coaxial high power microwave source based on dual beams, which combines a relativistic backward wave oscillator (RBWO) (noted as the inner sub-source below) and a coaxial transit-time oscillator (TTO) (noted as the outer sub-source). The cathode consists of an inner and an outer annular cathode, which provides the inner and the outer annular electron beam for the sub-sources, respectively. Particle-in-cell (PIC) simulation results demonstrate that power conversion efficiencies of the two sub-sources with an identical frequency of 9.74 GHz are 29% and 25%, respectively. It is furthermore found that phase locking between the inner and the outer sub-sources can be realized, which suggests a feasibility to obtain a higher power output if the two microwave signals are coherently combined.

  6. A new coaxial high power microwave source based on dual beams

    SciTech Connect

    Li, Yangmei Zhang, Xiaoping; Qi, Zumin; Dang, Fangchao; Qian, Baoliang

    2014-05-15

    We present a new coaxial high power microwave source based on dual beams, which combines a relativistic backward wave oscillator (RBWO) (noted as the inner sub-source below) and a coaxial transit-time oscillator (TTO) (noted as the outer sub-source). The cathode consists of an inner and an outer annular cathode, which provides the inner and the outer annular electron beam for the sub-sources, respectively. Particle-in-cell (PIC) simulation results demonstrate that power conversion efficiencies of the two sub-sources with an identical frequency of 9.74 GHz are 29% and 25%, respectively. It is furthermore found that phase locking between the inner and the outer sub-sources can be realized, which suggests a feasibility to obtain a higher power output if the two microwave signals are coherently combined.

  7. A High-Power Reflector Impulse Antenna with Dual-Tem Source

    NASA Astrophysics Data System (ADS)

    Guo, Chen; Zhang, An-Xue; Wu, Hui; Jiang, Yan-Sheng; Wang, Wen-Bing

    2008-09-01

    There are different demands on radiation efficiency and direction pattern according to various ultra-wideband (UWB) antennas and high power applications. To obtain more radiating gain on bore-sight of paraboloidal reflector and centralized radiating direction, a novel feeding structure called dual-TEM source has been designed and applied in half-paraboloidal reflector impulse radiating antenna (IRA) applications. Simulation results proved that this proposed half-paraboloidal reflector IRA with dual-TEM source provided greater radiation performance on bore-sight as a result of the synthesized power in the aperture space of paraboloid. Moreover, lots of simulation work and comparison have been done in different feeding models to summarize a relative optimal feeding structure.

  8. Dual-Source Multi-Energy CT with Triple or Quadruple X-ray Beams.

    PubMed

    Yu, Lifeng; Leng, Shuai; McCollough, Cynthia H

    2016-02-01

    Energy-resolved photon-counting CT (PCCT) is promising for material decomposition with multi-contrast agents. However, corrections for non-idealities of PCCT detectors are required, which are still active research areas. In addition, PCCT is associated with very high cost due to lack of mass production. In this work, we proposed an alternative approach to performing multi-energy CT, which was achieved by acquiring triple or quadruple x-ray beam measurements on a dual-source CT scanner. This strategy was based on a "Twin Beam" design on a single-source scanner for dual-energy CT. Examples of beam filters and spectra for triple and quadruple x-ray beam were provided. Computer simulation studies were performed to evaluate the accuracy of material decomposition for multi-contrast mixtures using a tri-beam configuration. The proposed strategy can be readily implemented on a dual-source scanner, which may allow material decomposition of multi-contrast agents to be performed on clinical CT scanners with energy-integrating detector.

  9. Dual-Source Multi-Energy CT with Triple or Quadruple X-ray Beams

    PubMed Central

    Yu, Lifeng; Leng, Shuai; McCollough, Cynthia H.

    2016-01-01

    Energy-resolved photon-counting CT (PCCT) is promising for material decomposition with multi-contrast agents. However, corrections for non-idealities of PCCT detectors are required, which are still active research areas. In addition, PCCT is associated with very high cost due to lack of mass production. In this work, we proposed an alternative approach to performing multi-energy CT, which was achieved by acquiring triple or quadruple x-ray beam measurements on a dual-source CT scanner. This strategy was based on a “Twin Beam” design on a single-source scanner for dual-energy CT. Examples of beam filters and spectra for triple and quadruple x-ray beam were provided. Computer simulation studies were performed to evaluate the accuracy of material decomposition for multi-contrast mixtures using a tri-beam configuration. The proposed strategy can be readily implemented on a dual-source scanner, which may allow material decomposition of multi-contrast agents to be performed on clinical CT scanners with energy-integrating detector. PMID:27330237

  10. Dual-source multi-energy CT with triple or quadruple x-ray beams

    NASA Astrophysics Data System (ADS)

    Yu, Lifeng; Li, Zhoubo; Leng, Shuai; McCollough, Cynthia H.

    2016-03-01

    Energy-resolved photon-counting CT (PCCT) is promising for material decomposition with multi-contrast agents. However, corrections for non-idealities of PCCT detectors are required, which are still active research areas. In addition, PCCT is associated with very high cost due to lack of mass production. In this work, we proposed an alternative approach to performing multi-energy CT, which was achieved by acquiring triple or quadruple x-ray beam measurements on a dual-source CT scanner. This strategy was based on a "Twin Beam" design on a single-source scanner for dual-energy CT. Examples of beam filters and spectra for triple and quadruple x-ray beam were provided. Computer simulation studies were performed to evaluate the accuracy of material decomposition for multi-contrast mixtures using both tri-beam and quadruple-beam configurations. The proposed strategy can be readily implemented on a dual-source scanner, which may allow material decomposition of multi-contrast agents to be performed on clinical CT scanners with energy-integrating detector.

  11. Scatter correction associated with dedicated dual-source CT hardware improves accuracy of lung air measures.

    PubMed

    Mobberley, Sean D; Fuld, Matthew K; Sieren, Jered P; Primak, Andrew N; Hoffman, Eric A

    2013-11-01

    Accurate assessment of air density used to quantitatively characterize amount and distribution of emphysema in chronic obstructive pulmonary disease (COPD) subjects has remained challenging. Hounsfield units (HU) within tracheal air can be considerably less negative than -1000 HU. This study has sought to characterize the effects of improved scatter correction used in dual-source pulmonary computed tomography (CT). Dual-source dual-energy (DSDE) and single-source (SS) scans taken at multiple energy levels and scan settings were acquired for quantitative comparison using anesthetized ovine (n = 6), swine (n = 13), and a lung phantom. Data were evaluated for the lung, inferior vena cava, and tracheal segments. To minimize the effect of cross-scatter, the phantom scans in the DSDE mode were obtained by reducing the current of one of the tubes to near zero. A significant shift in mean HU values in the tracheal regions of animals and the phantom is observed, with values consistently closer to -1000 HU in DSDE mode. HU values associated with SS mode demonstrated a positive shift of up to 32 HU. In vivo tracheal air measurements demonstrated considerable variability with SS scanning, whereas these values were more consistent with DSDE imaging. Scatter effects in the lung parenchyma differed from adjacent tracheal measures. Data suggest that the scatter correction introduced into the dual-energy mode of imaging has served to provide more accurate CT lung density measures sought to quantitatively assess the presence and distribution of emphysema in COPD subjects. Data further suggest that CT images, acquired without adequate scatter correction, cannot be corrected by linear algorithms given the variability in tracheal air HU values and the independent scatter effects on lung parenchyma. Copyright © 2013 AUR. Published by Elsevier Inc. All rights reserved.

  12. Possible Dual Earthquake-Landslide Source of the 13 November 2016 Kaikoura, New Zealand Tsunami

    NASA Astrophysics Data System (ADS)

    Heidarzadeh, Mohammad; Satake, Kenji

    2017-08-01

    A complicated earthquake (M w 7.8) in terms of rupture mechanism occurred in the NE coast of South Island, New Zealand, on 13 November 2016 (UTC) in a complex tectonic setting comprising a transition strike-slip zone between two subduction zones. The earthquake generated a moderate tsunami with zero-to-crest amplitude of 257 cm at the near-field tide gauge station of Kaikoura. Spectral analysis of the tsunami observations showed dual peaks at 3.6-5.7 and 5.7-56 min, which we attribute to the potential landslide and earthquake sources of the tsunami, respectively. Tsunami simulations showed that a source model with slip on an offshore plate-interface fault reproduces the near-field tsunami observation in terms of amplitude, but fails in terms of tsunami period. On the other hand, a source model without offshore slip fails to reproduce the first peak, but the later phases are reproduced well in terms of both amplitude and period. It can be inferred that an offshore source is necessary to be involved, but it needs to be smaller in size than the plate interface slip, which most likely points to a confined submarine landslide source, consistent with the dual-peak tsunami spectrum. We estimated the dimension of the potential submarine landslide at 8-10 km.

  13. Improved dual-energy material discrimination for dual-source CT by means of additional spectral filtration

    PubMed Central

    Primak, A. N.; Ramirez Giraldo, J. C.; Liu, X.; Yu, L.; McCollough, C. H.

    2009-01-01

    The use of additional spectral filtration for dual-energy (DE) imaging using a dual-source CT (DSCT) system was investigated and its effect on the material-specific DEratio was evaluated for several clinically relevant materials. The x-ray spectra, data acquisition, and reconstruction processes for a DSCT system (Siemens Definition) were simulated using information provided by the system manufacturer, resulting in virtual DE images. The factory-installed filtration for the 80 kV spectrum was left unchanged to avoid any further reductions in tube output, and only the filtration for the high-energy spectrum was modified. Only practical single-element filter materials within the atomic number range of 40≤Z≤83 were evaluated, with the aim of maximizing the separation between the two spectra, while maintaining similar noise levels for high- and low-energy images acquired at the same tube current. The differences between mean energies and the ratio of the 140 and 80 kV detector signals, each integrated below 80 keV, were evaluated. The simulations were performed for three attenuation scenarios: Head, body, and large body. The large body scenario was evaluated for the DE acquisition mode using the 100 and 140 kV spectra. The DEratio for calcium hydroxyapatite (simulating bone or calcifications), iodine, and iron were determined for CT images simulated using the modified and factory-installed filtration. Several filter materials were found to perform well at proper thicknesses, with tin being a good practical choice. When image noise was matched between the low- and high-energy images, the spectral difference in mean absorbed energy using tin was increased from 25.7 to 42.7 keV (head), from 28.6 to 44.1 keV (body), and from 20.2 to 30.2 keV (large body). The overlap of the signal spectra for energies below 80 keV was reduced from 78% to 31% (head), from 93% to 27% (body), and from 106% to 79% (large body). The DEratio for the body attenuation scenario increased from 1

  14. Electrostatic energy harvesting device with dual resonant structure for wideband random vibration sources at low frequency.

    PubMed

    Zhang, Yulong; Wang, Tianyang; Zhang, Ai; Peng, Zhuoteng; Luo, Dan; Chen, Rui; Wang, Fei

    2016-12-01

    In this paper, we present design and test of a broadband electrostatic energy harvester with a dual resonant structure, which consists of two cantilever-mass subsystems each with a mass attached at the free edge of a cantilever. Comparing to traditional devices with single resonant frequency, the proposed device with dual resonant structure can resonate at two frequencies. Furthermore, when one of the cantilever-masses is oscillating at resonance, the vibration amplitude is large enough to make it collide with the other mass, which provides strong mechanical coupling between the two subsystems. Therefore, this device can harvest a decent power output from vibration sources at a broad frequency range. During the measurement, continuous power output up to 6.2-9.8 μW can be achieved under external vibration amplitude of 9.3 m/s(2) at a frequency range from 36.3 Hz to 48.3 Hz, which means the bandwidth of the device is about 30% of the central frequency. The broad bandwidth of the device provides a promising application for energy harvesting from the scenarios with random vibration sources. The experimental results indicate that with the dual resonant structure, the vibration-to-electricity energy conversion efficiency can be improved by 97% when an external random vibration with a low frequency filter is applied.

  15. Versatile compact atomic source for high-resolution dual atom interferometry

    SciTech Connect

    Mueller, T.; Wendrich, T.; Gilowski, M.; Jentsch, C.; Rasel, E. M.; Ertmer, W.

    2007-12-15

    We present a compact {sup 87}Rb atomic source for high precision dual atom interferometers. The source is based on a double-stage magneto-optical trap (MOT) design, consisting of a two-dimensional (2D) -MOT for efficient loading of a 3D-MOT. The accumulated atoms are precisely launched in a horizontal moving molasses. Our source generates a high atomic flux (>10{sup 10} atoms/s) with precise and flexibly tunable atomic trajectories as required for high resolution Sagnac atom interferometry. We characterize the performance of the source with respect to the relevant parameters of the launched atoms, i.e., temperature, absolute velocity, and pointing, by utilizing time-of-flight techniques and velocity selective Raman transitions.

  16. Versatile compact atomic source for high-resolution dual atom interferometry

    NASA Astrophysics Data System (ADS)

    Müller, T.; Wendrich, T.; Gilowski, M.; Jentsch, C.; Rasel, E. M.; Ertmer, W.

    2007-12-01

    We present a compact R87b atomic source for high precision dual atom interferometers. The source is based on a double-stage magneto-optical trap (MOT) design, consisting of a two-dimensional (2D) -MOT for efficient loading of a 3D-MOT. The accumulated atoms are precisely launched in a horizontal moving molasses. Our source generates a high atomic flux (>1010atoms/s) with precise and flexibly tunable atomic trajectories as required for high resolution Sagnac atom interferometry. We characterize the performance of the source with respect to the relevant parameters of the launched atoms, i.e., temperature, absolute velocity, and pointing, by utilizing time-of-flight techniques and velocity selective Raman transitions.

  17. Comparison between single- and dual-electrode ion source systems for low-energy ion transport

    SciTech Connect

    Vasquez, M. Jr.; Tokumura, S.; Kasuya, T.; Maeno, S.; Wada, M.

    2012-11-06

    Extraction of ions with energies below 100 eV has been demonstrated using a hot-cathode multi-cusp ion source equipped with extraction electrodes made of thin wires. Two electrode geometries, a single-electrode system, and a dual-electrode system were built and tested. The single-electrode configuration showed high ion beam current densities at shorter distances from the electrode but exhibited rapid attenuation as the distance from the electrode increased. Beam angular spread measurements showed similar beam divergence for both electrode configurations at low plasma densities. At high plasma densities and low extraction potentials, the single-electrode system showed the angular spread twice as large as that of the dual-electrode system. Energy distribution analyses showed a broader energy spread for ion beams extracted from a single-electrode set-up.

  18. A new compact self-coherent high power microwave source based on dual beams

    SciTech Connect

    Yan, Xiaolu Zhang, Xiaoping; Li, Yangmei; Qi, Zumin; Dang, Fangchao

    2015-05-15

    In this paper, a compact self-coherent high power microwave source based on dual beams is presented. It consists of a two-cavity triaxial klystron amplifier (TKA) (noted as the outer sub-source below) and a multiwave Cerenkov generators (noted as the inner sub-source) inserted in the TKA's inner conductor. These two sub-sources share a common cathode and the magnetic field. The injected signals to the outer sub-source are leakage microwaves from the inner sub-source through the anode-cathode gap (A-K gap). Particle-in-cell simulation shows that when the diode voltage is 687 kV and the axial magnetic field is 0.8 T, two microwaves with power of 1.02 GW and 2.65 GW and the same frequency of 9.72 GHz are generated in the inner and the outer sub-source, respectively; the corresponding power efficiencies are 24% and 31%. Two sub-sources reach the phase locking at 23 ns with a phase difference fluctuation within ±3°. The fast and stable phase locking in the voltage ranging from 665 kV to 709 kV further suggests that the proposed source is promising for coherent power combination and to export a higher power of combined microwaves.

  19. A new compact self-coherent high power microwave source based on dual beams

    NASA Astrophysics Data System (ADS)

    Yan, Xiaolu; Zhang, Xiaoping; Li, Yangmei; Qi, Zumin; Dang, Fangchao

    2015-05-01

    In this paper, a compact self-coherent high power microwave source based on dual beams is presented. It consists of a two-cavity triaxial klystron amplifier (TKA) (noted as the outer sub-source below) and a multiwave Cerenkov generators (noted as the inner sub-source) inserted in the TKA's inner conductor. These two sub-sources share a common cathode and the magnetic field. The injected signals to the outer sub-source are leakage microwaves from the inner sub-source through the anode-cathode gap (A-K gap). Particle-in-cell simulation shows that when the diode voltage is 687 kV and the axial magnetic field is 0.8 T, two microwaves with power of 1.02 GW and 2.65 GW and the same frequency of 9.72 GHz are generated in the inner and the outer sub-source, respectively; the corresponding power efficiencies are 24% and 31%. Two sub-sources reach the phase locking at 23 ns with a phase difference fluctuation within ±3°. The fast and stable phase locking in the voltage ranging from 665 kV to 709 kV further suggests that the proposed source is promising for coherent power combination and to export a higher power of combined microwaves.

  20. An adaptable dual species effusive source and Zeeman slower design demonstrated with Rb and Li

    SciTech Connect

    Bowden, William Gunton, Will; Semczuk, Mariusz; Dare, Kahan; Madison, Kirk W.

    2016-04-15

    We present a dual-species effusive source and Zeeman slower designed to produce slow atomic beams of two elements with a large mass difference and with very different oven temperature requirements. We demonstrate this design for the case of {sup 6}Li and {sup 85}Rb and achieve magneto-optical trap (MOT) loading rates equivalent to that reported in prior work on dual species (Rb+Li) Zeeman slowers operating at the same oven temperatures. Key design choices, including thermally separating the effusive sources and using a segmented coil design to enable computer control of the magnetic field profile, ensure that the apparatus can be easily modified to slow other atomic species. By performing the final slowing using the quadrupole magnetic field of the MOT, we are able to shorten our Zeeman slower length making for a more compact system without compromising performance. We outline the construction and analyze the emission properties of our effusive sources. We also verify the performance of the source and slower, and we observe sequential loading rates of 12 × 10{sup 8} atoms/s for a Rb oven temperature of 140 °C and 1.1 × 10{sup 8} atoms/s for a Li reservoir at 460 °C, corresponding to reservoir lifetimes for continuous operation of 10 and 4 years, respectively.

  1. An adaptable dual species effusive source and Zeeman slower design demonstrated with Rb and Li.

    PubMed

    Bowden, William; Gunton, Will; Semczuk, Mariusz; Dare, Kahan; Madison, Kirk W

    2016-04-01

    We present a dual-species effusive source and Zeeman slower designed to produce slow atomic beams of two elements with a large mass difference and with very different oven temperature requirements. We demonstrate this design for the case of (6)Li and (85)Rb and achieve magneto-optical trap (MOT) loading rates equivalent to that reported in prior work on dual species (Rb+Li) Zeeman slowers operating at the same oven temperatures. Key design choices, including thermally separating the effusive sources and using a segmented coil design to enable computer control of the magnetic field profile, ensure that the apparatus can be easily modified to slow other atomic species. By performing the final slowing using the quadrupole magnetic field of the MOT, we are able to shorten our Zeeman slower length making for a more compact system without compromising performance. We outline the construction and analyze the emission properties of our effusive sources. We also verify the performance of the source and slower, and we observe sequential loading rates of 12 × 10(8) atoms/s for a Rb oven temperature of 140 °C and 1.1 × 10(8) atoms/s for a Li reservoir at 460 °C, corresponding to reservoir lifetimes for continuous operation of 10 and 4 years, respectively.

  2. Quantitative assessment of scatter correction techniques incorporated in next generation dual-source computed tomography

    NASA Astrophysics Data System (ADS)

    Mobberley, Sean David

    Accurate, cross-scanner assessment of in-vivo air density used to quantitatively assess amount and distribution of emphysema in COPD subjects has remained elusive. Hounsfield units (HU) within tracheal air can be considerably more positive than -1000 HU. With the advent of new dual-source scanners which employ dedicated scatter correction techniques, it is of interest to evaluate how the quantitative measures of lung density compare between dual-source and single-source scan modes. This study has sought to characterize in-vivo and phantom-based air metrics using dual-energy computed tomography technology where the nature of the technology has required adjustments to scatter correction. Anesthetized ovine (N=6), swine (N=13: more human-like rib cage shape), lung phantom and a thoracic phantom were studied using a dual-source MDCT scanner (Siemens Definition Flash. Multiple dual-source dual-energy (DSDE) and single-source (SS) scans taken at different energy levels and scan settings were acquired for direct quantitative comparison. Density histograms were evaluated for the lung, tracheal, water and blood segments. Image data were obtained at 80, 100, 120, and 140 kVp in the SS mode (B35f kernel) and at 80, 100, 140, and 140-Sn (tin filtered) kVp in the DSDE mode (B35f and D30f kernels), in addition to variations in dose, rotation time, and pitch. To minimize the effect of cross-scatter, the phantom scans in the DSDE mode was obtained by reducing the tube current of one of the tubes to its minimum (near zero) value. When using image data obtained in the DSDE mode, the median HU values in the tracheal regions of all animals and the phantom were consistently closer to -1000 HU regardless of reconstruction kernel (chapters 3 and 4). Similarly, HU values of water and blood were consistently closer to their nominal values of 0 HU and 55 HU respectively. When using image data obtained in the SS mode the air CT numbers demonstrated a consistent positive shift of up to 35 HU

  3. Coronary fly-through or virtual angioscopy using dual-source MDCT data.

    PubMed

    van Ooijen, Peter M A; de Jonge, Gonda; Oudkerk, Matthijs

    2007-11-01

    Coronary fly-through or virtual angioscopy (VA) has been studied ever since its invention in 2000. However, application was limited because it requires an optimal computed tomography (CT) scan and time-consuming post-processing. Recent advances in post-processing software facilitate easy construction of VA, but until now image quality was insufficient in most patients. The introduction of dual-source multidetector CT (MDCT) could enable VA in all patients. Twenty patients were scanned using a dual-source MDCT (Definition, Siemens, Forchheim, Germany) using a standard coronary artery protocol. Post-processing was performed on an Aquarius Workstation (TeraRecon, San Mateo, Calif.). Length travelled per major branch was recorded in millimetres, together with the time required in minutes. VA could be performed in every patient for each of the major coronary arteries. The mean (range) length of the automated fly-through was 80 (32-107) mm for the left anterior descending (LAD), 75 (21-116) mm for the left circumflex artery (LCx), and 109 (21-190) mm for the right coronary artery (RCA). Calcifications and stenoses were visualised, as well as most side branches. The mean time required was 3 min for LAD, 2.5 min for LCx, and 2 min for the RCA. Dual-source MDCT allows for high quality visualisation of the coronary arteries in every patient because scanning with this machine is independent of the heart rate. This is clearly shown by the successful VA in all patients. Potential clinical value of VA should be determined in the near future.

  4. Supercontinuum optimization for dual-soliton based light sources using genetic algorithms in a grid platform.

    PubMed

    Arteaga-Sierra, F R; Milián, C; Torres-Gómez, I; Torres-Cisneros, M; Moltó, G; Ferrando, A

    2014-09-22

    We present a numerical strategy to design fiber based dual pulse light sources exhibiting two predefined spectral peaks in the anomalous group velocity dispersion regime. The frequency conversion is based on the soliton fission and soliton self-frequency shift occurring during supercontinuum generation. The optimization process is carried out by a genetic algorithm that provides the optimum input pulse parameters: wavelength, temporal width and peak power. This algorithm is implemented in a Grid platform in order to take advantage of distributed computing. These results are useful for optical coherence tomography applications where bell-shaped pulses located in the second near-infrared window are needed.

  5. Dual-etalon cavity ring-down frequency-comb spectroscopy with broad band light source

    DOEpatents

    Chandler, David W; Strecker, Kevin E

    2014-04-01

    In an embodiment, a dual-etalon cavity-ring-down frequency-comb spectrometer system is described. A broad band light source is split into two beams. One beam travels through a first etalon and a sample under test, while the other beam travels through a second etalon, and the two beams are recombined onto a single detector. If the free spectral ranges ("FSR") of the two etalons are not identical, the interference pattern at the detector will consist of a series of beat frequencies. By monitoring these beat frequencies, optical frequencies where light is absorbed may be determined.

  6. Preliminary experimental investigation of a complex dual-band high power microwave source

    SciTech Connect

    Zhang, Xiaoping Li, Yangmei; Li, Zhiqiang; Zhong, Huihuang; Qian, Baoliang

    2015-10-15

    In order to promote the power conversion efficiency of a magnetically insulated transmission line oscillator (MILO) and obtain microwaves in dual bands, an axially extracted C-band virtual cathode oscillator (VCO) with multiple resonant cavities is introduced to partially utilize the load current of an S-band MILO. The formed novel dual-band high power microwave source called MILO and VCO is investigated with simulation and experimentally. A dual-band radiation antenna is designed to effectively radiate microwaves generated by the MILO and the VCO, respectively, while avoiding them being influenced by the microwave reflection and diffraction. The preliminary experimental results measured by the dual-band diagnostic system show that both the MILO and the VCO operate normally under repeated shots. A microwave of 2.1 GHz, 1.70 GW is generated from the MILO and a 0.37 GW microwave at frequencies of 4.1 GHz and 3.8 GHz is generated from the VCO under the condition of about 440 kV and 35 kA. Compared with a single MILO (10.6%), a MILO and VCO achieves higher total power and efficiency (13.4%) in both S and C bands, indicating that the load current of the MILO partially couples into the beam-wave interaction in the VCO and then contributes to the output microwaves. However, more works are needed regarding the spectrum purification of the VCO and promotion of the output power of both the MILO and the VCO.

  7. Preliminary experimental investigation of a complex dual-band high power microwave source.

    PubMed

    Zhang, Xiaoping; Li, Yangmei; Li, Zhiqiang; Zhong, Huihuang; Qian, Baoliang

    2015-10-01

    In order to promote the power conversion efficiency of a magnetically insulated transmission line oscillator (MILO) and obtain microwaves in dual bands, an axially extracted C-band virtual cathode oscillator (VCO) with multiple resonant cavities is introduced to partially utilize the load current of an S-band MILO. The formed novel dual-band high power microwave source called MILO and VCO is investigated with simulation and experimentally. A dual-band radiation antenna is designed to effectively radiate microwaves generated by the MILO and the VCO, respectively, while avoiding them being influenced by the microwave reflection and diffraction. The preliminary experimental results measured by the dual-band diagnostic system show that both the MILO and the VCO operate normally under repeated shots. A microwave of 2.1 GHz, 1.70 GW is generated from the MILO and a 0.37 GW microwave at frequencies of 4.1 GHz and 3.8 GHz is generated from the VCO under the condition of about 440 kV and 35 kA. Compared with a single MILO (10.6%), a MILO and VCO achieves higher total power and efficiency (13.4%) in both S and C bands, indicating that the load current of the MILO partially couples into the beam-wave interaction in the VCO and then contributes to the output microwaves. However, more works are needed regarding the spectrum purification of the VCO and promotion of the output power of both the MILO and the VCO.

  8. Preliminary experimental investigation of a complex dual-band high power microwave source

    NASA Astrophysics Data System (ADS)

    Zhang, Xiaoping; Li, Yangmei; Li, Zhiqiang; Zhong, Huihuang; Qian, Baoliang

    2015-10-01

    In order to promote the power conversion efficiency of a magnetically insulated transmission line oscillator (MILO) and obtain microwaves in dual bands, an axially extracted C-band virtual cathode oscillator (VCO) with multiple resonant cavities is introduced to partially utilize the load current of an S-band MILO. The formed novel dual-band high power microwave source called MILO and VCO is investigated with simulation and experimentally. A dual-band radiation antenna is designed to effectively radiate microwaves generated by the MILO and the VCO, respectively, while avoiding them being influenced by the microwave reflection and diffraction. The preliminary experimental results measured by the dual-band diagnostic system show that both the MILO and the VCO operate normally under repeated shots. A microwave of 2.1 GHz, 1.70 GW is generated from the MILO and a 0.37 GW microwave at frequencies of 4.1 GHz and 3.8 GHz is generated from the VCO under the condition of about 440 kV and 35 kA. Compared with a single MILO (10.6%), a MILO and VCO achieves higher total power and efficiency (13.4%) in both S and C bands, indicating that the load current of the MILO partially couples into the beam-wave interaction in the VCO and then contributes to the output microwaves. However, more works are needed regarding the spectrum purification of the VCO and promotion of the output power of both the MILO and the VCO.

  9. Nonequilibrium atmospheric pressure plasma jet using a combination of 50 kHz/2 MHz dual-frequency power sources

    SciTech Connect

    Zhou, Yong-Jie; Yuan, Qiang-Hua; Li, Fei; Wang, Xiao-Min; Yin, Gui-Qin; Dong, Chen-Zhong

    2013-11-15

    An atmospheric pressure plasma jet is generated by dual sinusoidal wave (50 kHz and 2 MHz). The dual-frequency plasma jet exhibits the advantages of both low frequency and radio frequency plasmas, namely, the long plasma plume and the high electron density. The radio frequency ignition voltage can be reduced significantly by using dual-frequency excitation compared to the conventional radio frequency without the aid of the low frequency excitation source. A larger operating range of α mode discharge can be obtained using dual-frequency excitation which is important to obtain homogeneous and low-temperature plasma. A larger controllable range of the gas temperature of atmospheric pressure plasma could also be obtained using dual-frequency excitation.

  10. Comparison of dual rotating Scheimpflug-Placido, swept-source optical coherence tomography, and Placido-scanning-slit systems.

    PubMed

    Lee, Yong Woo; Choi, Chul Young; Yoon, Geun Young

    2015-05-01

    To compare measurements of corneal indices using dual rotating Scheimpflug-Placido, swept-source optical coherence tomography (OCT), and Placido-scanning-slit systems. Kangbuk Samsung Hospital, Seoul, South Korea. Prospective evaluation of diagnostic tests. Corneal topography measurements were performed using dual rotating Scheimpflug-Placido (Galilei G2), swept-source OCT (Casia SS-1000), and Placido-scanning-slit (Orbscan IIz) systems. The intraclass correlation coefficients (ICCs) and Bland-Altman plots were used to evaluate the agreement between measurements. Fifty post-refractive surgery eyes and 50 normal eyes were evaluated. The agreement in anterior keratometry and pachymetry between the 3 devices was high in both groups (ICC > 0.9). In both groups, the ICC values for posterior keratometry and eccentricity were high between the dual rotating Scheimpflug-Placido and swept-source OCT systems (ICC > 0.9) but not between the Placido-scanning-slit system and the other 2 systems. The Placido-scanning-slit system yielded much steeper values for posterior keratometry in both groups (P < .05). The ICC values for posterior corneal elevation were lower than 0.9 between all 3 devices. The dual rotating Scheimpflug-Placido and swept-source OCT systems showed relatively higher ICC values than the Placido-scanning-slit system in both groups. Maximum posterior elevations were highest with the Placido-scanning-slit system followed by the swept-source OCT system and then the dual rotating Scheimpflug-Placido system. Anterior keratometry obtained using 3 devices showed high degrees of agreement. Posterior keratometry and eccentricity showed greater agreement between the dual rotating Scheimpflug-Placido and swept-source OCT systems than with the Placido-scanning-slit system. The dual rotating Scheimpflug-Placido and swept-source OCT systems were equivalent in detecting the shape of the cornea and could be considered interchangeable. Copyright © 2015. Published by Elsevier

  11. Frequency-domain endoscopic diffuse optical tomography reconstruction algorithm based on dual-modulation-frequency and dual-points source diffuse equation

    NASA Astrophysics Data System (ADS)

    Qin, Zhuanping; Hou, Qiang; Zhao, Huijuan; Yang, Yanshuang; Zhou, Xiaoqing; Gao, Feng

    2013-03-01

    In this paper, frequency-domain endoscopic diffuse optical tomography image reconstruction algorithm based on dual-modulation-frequency and dual-points source diffuse equation is investigated for the reconstruction of the optical parameters including the absorption and reducing scattering coefficients. The forward problem is solved by the finite element method based on the frequency domain diffuse equation (FD-DE) for dual-points source approximation and multi-modulation-frequency. In the image reconstruction, a multi-modulation-frequency Newton-Raphson algorithm is applied to obtain the solution. To further improve the image accuracy and quality, a method based on the region of interest (ROI) is applied on the above procedures. The simulation is performed in the tubular model to verify the validity of the algorithm. Results show that the FD-DE with dual-points source approximate is more accuracy at shorter source-detector separation. The reconstruction with dual-modulation-frequency improves the image accuracy and quality compared to the results with single-modulation-frequency and triple-modulation-frequency method. The peak optical coefficients in ROI (ROI_max) are almost equivalent to the true optical coefficients with the relative error less than 6.67%. The full width at half maximum (FWHM) achieves 82% of the true radius. The contrast-to-noise ratio (CNR) and image coefficient(IC) is 5.678 and 26.962, respectively. Additionally, the results with the method based on ROI show that the ROI_max is equivalent to the true value. The FWHM can improve by 88% of the true radius. The CNR and IC is improved over 7.782 and 45.335, respectively.

  12. Probabilistic conditional reasoning: Disentangling form and content with the dual-source model.

    PubMed

    Singmann, Henrik; Klauer, Karl Christoph; Beller, Sieghard

    2016-08-01

    The present research examines descriptive models of probabilistic conditional reasoning, that is of reasoning from uncertain conditionals with contents about which reasoners have rich background knowledge. According to our dual-source model, two types of information shape such reasoning: knowledge-based information elicited by the contents of the material and content-independent information derived from the form of inferences. Two experiments implemented manipulations that selectively influenced the model parameters for the knowledge-based information, the relative weight given to form-based versus knowledge-based information, and the parameters for the form-based information, validating the psychological interpretation of these parameters. We apply the model to classical suppression effects dissecting them into effects on background knowledge and effects on form-based processes (Exp. 3) and we use it to reanalyse previous studies manipulating reasoning instructions. In a model-comparison exercise, based on data of seven studies, the dual-source model outperformed three Bayesian competitor models. Overall, our results support the view that people make use of background knowledge in line with current Bayesian models, but they also suggest that the form of the conditional argument, irrespective of its content, plays a substantive, yet smaller, role. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. A stochastic inventory management model for a dual sourcing supply chain with disruptions

    NASA Astrophysics Data System (ADS)

    Iakovou, Eleftherios; Vlachos, Dimitrios; Xanthopoulos, Anastasios

    2010-03-01

    As companies continue to globalise their operations and outsource significant portion of their value chain activities, they often end up relying heavily on order replenishments from distant suppliers. The explosion in long-distance sourcing is exposing supply chains and shareholder value at ever increasing operational and disruption risks. It is well established, both in academia and in real-world business environments, that resource flexibility is an effective method for hedging against supply chain disruption risks. In this contextual framework, we propose a single period stochastic inventory decision-making model that could be employed for capturing the trade-off between inventory policies and disruption risks for an unreliable dual sourcing supply network for both the capacitated and uncapacitated cases. Through the developed model, we obtain some important managerial insights and evaluate the merit of contingency strategies in managing uncertain supply chains.

  14. Correction of cross-scatter in next generation dual source CT (DSCT) scanners

    NASA Astrophysics Data System (ADS)

    Bruder, H.; Stierstorfer, K.; Petersilka, M.; Wiegand, C.; Suess, C.; Flohr, T.

    2008-03-01

    In dual source CT (DSCT) with two X-ray sources and two data measurement systems mounted on a CT gantry with a mechanical offset of 90 deg, cross scatter radiation, (essentially 90 deg Compton scatter) is added to the detector signals. In current DSCT scanners the cross scatter correction is model based: the idea is to describe the scattering surface in terms of its tangents. The positions of these tangent lines are used to characterize the shape of the scattering object. For future DSCT scanners with larger axial X-ray beams, the model based correction will not perfectly remove the scatter signal in certain clinical situations: for obese patients scatter artifacts in cardiac dual source scan modes might occur. These shortcomings can be circumvented by utilizing the non-diagnostic time windows in cardiac scan modes to detect cross scatter online. The X-ray generators of both systems have to be switched on and off alternating. If one X-ray source is switched off, cross scatter deposited in the respective other detector can be recorded and processed, to be used for efficient cross scatter correction. The procedure will be demonstrated for cardiac step&shoot as well as for spiral acquisitions. Full rotation reconstructions are less sensitive to cross scatter radiation; hence in non-cardiac case the model-based approach is sufficient. Based on measurements of physical and anthropomorphic phantoms we present image data for DSCT systems with various collimator openings demonstrating the efficacy of the proposed method. In addition, a thorough analysis of contrast-to-noise ratio (CNR) shows, that even for a X-ray beam corresponding to a 64x0.6 mm collimation, the maximum loss of CNR due to cross scatter is only about 7% in case of obese patients.

  15. Radiant, virtual, and dual sources of optical fields in any state of spatial coherence.

    PubMed

    Castañeda, Román; Cañas-Cardona, Gustavo; Garcia-Sucerquia, Jorge

    2010-06-01

    A novel description of interference and diffraction with fields in arbitrary states of spatial coherence is introduced in the framework of the phase-space representation. The field is modeled as produced by radiant and virtual point sources. The first ones emit the radiant power of the field, independently of its spatial coherence state, and the second ones emit the modulating energy in strong dependence on such state. This energy can take on positive and negative values that produce the interference and diffraction patterns after adding them to the radiant energy. Radiant and virtual point sources at a given plane can be arranged over two distinct layers, which can be brought together to provide a unified structure of point sources for the field at such plane. So, the coincidence of specific radiant and virtual sources at the same point induces a further type: the dual point source. Descriptions of diffraction arrangements, Young's experiment with diffraction effects, and some implications of this model are discussed.

  16. Nitrogen sources and cycling in the San Francisco Bay estuary: A nitrate dual isotopic composition approach

    USGS Publications Warehouse

    Wankel, Scott D.; Kendall, C.; Francis, C.A.; Paytan, A.

    2006-01-01

    We used the dual isotopic composition of nitrate (??15N and ??18O) within the estuarine system of San Francisco (SF) Bay, California, to explore the utility of this approach for tracing sources and cycling of nitrate (NO3-). Surface water samples from 49 sites within the estuary were sampled during July-August 2004. Spatial variability in the isotopic composition suggests that there are multiple sources of nitrate to the bay ecosystem including seawater, several rivers and creeks, and sewage effluent. The spatial distribution of nitrate from these sources is heavily modulated by the hydrodynamics of the estuary. Mixing along the estuarine salinity gradient is the main control on the spatial variations in isotopic composition of nitrate within the northern arm of SF Bay. However, the nitrate isotopic composition in the southern arm of SF Bay exhibited a combination of source mixing and phytoplankton drawdown due mostly to the long residence time during the summer study period. Very low ?? 18ONO3 values (as low as -5.0???) at the Sacramento-San Joaquin River delta region give rise to a wide range of ??18ONO3 values in the SF Bay system. The range in ??18ONO3 values is more than twice that of (??15NNO3, suggesting that ??18O NO3 is an even more sensitive tool for tracing nitrate sources and cycling than ??15NNO3. ?? 2006, by the American Society of Limnology and Oceanography, Inc.

  17. Characterization of Urinary Stone Composition by Use of Third-Generation Dual-Source Dual-Energy CT With Increased Spectral Separation.

    PubMed

    Duan, Xinhui; Li, Zhoubo; Yu, Lifeng; Leng, Shuai; Halaweish, Ahmed F; Fletcher, Joel G; McCollough, Cynthia H

    2015-12-01

    The purpose of this phantom study was to determine the utility of a third-generation dual-source CT scanner with increased dual-energy spectral separation in differentiating urinary stone composition. Eighty-seven urinary stones from humans were scanned in 35-, 40-, 45-, and 50-cm wide anthropomorphic phantoms with a third-generation dual-source scanner (system A) with a high-energy beam of 150 kV plus 0.6-mm tin filtration (Sn). The low-energy data were acquired at 70, 80, 90, and 100 kV. A second-generation dual-source scanner (system B) was used to acquire data at 140 kV plus 0.4-mm Sn for the high-energy and 80 or 100 kV for the low-energy images. Volume CT dose index was matched for a given phantom size. CT number ratios were calculated and used to differentiate uric acid from non-uric acid stones and oxalate from apatite stones in an ROC analysis. The area under the curve (AUC) of the ROC curve for uric acid versus non-uric acid stones increased for large phantoms. For example, for imaging of the 45-cm wide phantom with system A at the 100- and 150-kV Sn low- and high-energy combination, the AUC was 0.99, whereas for system B at the 100- and 140-kV Sn combination, the AUC was 0.86. At each phantom size and for all energy combinations, the AUC values for oxalate versus apatite stones were higher for system A than they were for any energy combination for system B. Compared with use of second-generation dual-source CT, use of third-generation dual-source CT at the energy combination of 100 and 150 kV Sn improved classification of urinary stones across a wide range of phantom sizes and increased the ability to differentiate oxalate from apatite stones.

  18. Miniaturized silicon photonic integrated swept source OCT receiver with dual polarization, dual balanced, in-phase and quadrature detection (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Wang, Zhao; Lee, Hsiang-Chieh; Chen, Long; Vermeulen, Diedrik; Nielsen, Torben; Park, Seo Yeon; Ghaemi, Allan; Swanson, Eric; Doerr, Chris; Fujimoto, James

    2016-03-01

    Miniaturization and cost reduction of OCT systems are important for enabling many new clinical applications as well as accelerating the development of existing applications. Silicon photonics is an important low-cost, high-volume, multi-functional platform for integrated optics because it can benefit from existing semiconductor fabrication techniques to integrate many advanced optical functions onto a single microchip. We present a miniaturized silicon photonic integrated swept source OCT receiver, measuring 3×4mm2, with advanced functionalities including dual polarization, dual balanced, in-phase and quadrature detection, essentially enabling the detection of the full vector field (amplitude, phase, and polarization) of the optical signal. With this integrated receiver, we demonstrate full-range OCT for complex conjugate artifact suppression, polarization diversity detection for removing polarization fading artifact, and polarization sensitive OCT for tissue birefringence imaging. The silicon photonic integrated receiver is a key advance towards developing a miniaturized, multi-functional swept source OCT system.

  19. A dual-isotope approach to allow conclusive partitioning between three sources

    PubMed Central

    Whitman, Thea; Lehmann, Johannes

    2015-01-01

    Stable isotopes have proved to be a transformative tool; their application to distinguish between two sources in a mixture has been a cornerstone of biogeochemical research. However, quantitatively partitioning systems using two stable isotopes (for example, 13C and 12C) has been largely limited to only two sources, and systems of interest often have more than two components, with interactive effects. Here we introduce a dual-isotope approach to allow conclusive partitioning between three sources, using only two stable isotopes. We demonstrate this approach by partitioning soil CO2 emissions derived from microbial mineralization of soil organic carbon (SOC), added pyrogenic organic matter (PyOM) and root respiration. We find that SOC mineralization in the presence of roots is 23% higher (P<0.05) when PyOM is also present. Being able to discern three sources with two isotopes will be of great value not only in biogeochemical research, but may also expand hitherto untapped methodologies in diverse fields. PMID:26530521

  20. Broadly tunable femtosecond mid-infrared source based on dual photonic crystal fibers.

    PubMed

    Yao, Yuhong; Knox, Wayne H

    2013-11-04

    We report a novel scheme of generating broadly tunable femtosecond mid-IR pulses based on difference frequency mixing the outputs from dual photonic crystal fibers (PCF). With a 1.3 W, 1035 nm, 300 fs and 40 MHz Yb fiber chirped pulse amplifier as the laser source, a PCF with single zero dispersion wavelength (ZDW) at the laser wavelength is employed to spectrally broaden a portion of the laser pulses. Facilitated by self-phase modulation, its output spectrum possesses two dominant outermost peaks that can be extended to 970 nm and 1092 nm. A different PCF with two closely spaced ZDWs around the laser wavelength is used to generate the intense Stokes pulses between 1240 - 1260 nm. Frequency mixing the dual PCFs outputs in an AgGaS(2) crystal results in mid-IR pulses broadly tunable from 4.2 μm to 9 μm with a maximum average power of 640 µW at 4.5 μm, corresponding to 16 pJ of pulse energy.

  1. Wet-chemical synthesis of different bismuth telluride nanoparticles using metal organic precursors - single source vs. dual source approach.

    PubMed

    Bendt, Georg; Weber, Anna; Heimann, Stefan; Assenmacher, Wilfried; Prymak, Oleg; Schulz, Stephan

    2015-08-28

    Thermolysis of the single source precursor (Et2Bi)2Te in DIPB at 80 °C yielded phase-pure Bi4Te3 nanoparticles, while mixtures of Bi4Te3 and elemental Bi were formed at higher temperatures. In contrast, cubic Bi2Te particles were obtained by thermal decomposition of Et2BiTeEt in DIPB. Moreover, a dual source approach (hot injection method) using the reaction of Te(SiEt3)2 and Bi(NMe2)3 was applied for the synthesis of different pure Bi-Te phases including Bi2Te, Bi4Te3 and Bi2Te3, which were characterized by PXRD, REM, TEM and EDX. The influence of reaction temperature, precursor molar ratio and thermolysis conditions on the resulting material phase was verified. Moreover, reactions of alternate bismuth precursors such as Bi(NEt2)3, Bi(NMeEt)3 and BiCl3 with Te(SiEt3)2 were investigated.

  2. Financial Impact of Dual Vendor, Matrix Pricing, and Sole-Source Contracting on Implant Costs.

    PubMed

    Althausen, Peter L; Lapham, Joan; Mead, Lisa

    2016-12-01

    Implant costs comprise the largest proportion of operating room supply costs for orthopedic trauma care. Over the years, hospitals have devised several methods of controlling these costs with the help of physicians. With increasing economic pressure, these negotiations have a tremendous ability to decrease the cost of trauma care. In the past, physicians have taken no responsibility for implant pricing which has made cost control difficult. The reasons have been multifactorial. However, industry surgeon consulting fees, research support, and surgeon comfort with certain implant systems have played a large role in slowing adoption of cost-control measures. With the advent of physician gainsharing and comanagement agreements, physicians now have impetus to change. At our facility, we have used 3 methods for cost containment since 2009: dual vendor, matrix pricing, and sole-source contracting. Each has been increasingly successful, resulting in massive savings for the institution. This article describes the process and benefits of each model.

  3. Spatiotemporal optical similaritons in dual-core waveguide with an external source

    NASA Astrophysics Data System (ADS)

    Soloman Raju, Thokala

    2017-04-01

    We explore analytically and numerically the existence of exact asymptotic spatiotemporal optical self-similar light bullets to the nonlinear Schrödinger equation with gain in the presence of an external source in (3+1)-dimensions. This model appertains to the description of self-similar wave propagation through asymmetric planar dual-core waveguide (DWG) amplifiers. The asymmetric DWG is composed of two adjoining, closely spaced, upper and lower waveguides, in which the lower one acts as a passive waveguide while the upper waveguide is an active one. Due to the linear coupling between them, we can control the dynamical behaviors of the wave propagating through the passive waveguide by controlling the wave in active waveguide. We explicate the mechanism to control the dynamical behaviors of these self-similar waves for two specific cases: (i) when the gain and width are hyperbolic functions and (ii) when the gain and width are periodic functions.

  4. Note: Laser Doppler velocimeter using a dual-longitudinal-mode laser source

    NASA Astrophysics Data System (ADS)

    Xiaoming, Nie; Jian, Zhou; Xingwu, Long

    2012-10-01

    This paper presents a new laser Doppler technique using a dual-longitudinal-mode He-Ne laser as the laser source. Theoretical analysis shows that the Doppler frequency is proportional with the frequency difference of the two modes. The Doppler frequency in this technique is very low compared with the one in the single-mode laser Doppler technique. The new laser Doppler technique can be used to measure high speed. Experiment results show that the Doppler frequency is only about 82 Hz while the measurement speed reaches 31.4 m/s. The signal-to-noise ratio of the Doppler signal is improved by the technique of digital filter and digital autocorrelation.

  5. Source apportionment of carbonaceous aerosols over South and East Asia using dual carbon isotopes

    NASA Astrophysics Data System (ADS)

    Gustafsson, O.; Kirillova, E. N.; Andersson, A.-; Kruså, M.; Sheesley, R. J.; Tiwari, S.-; Lee, M.; Chen, B.; Du, K.

    2012-12-01

    contrary to the isotopic gradient expected for secondary organic aerosol (SOA) formation and instead suggests that WSOC in the South Asian regional receptor atmosphere stems largely from chemically-aged POA. The year-round dual-isotope data suggests that a key contribution to S Asian WSOC may be ageing of POA from incomplete biomass combustion. These top-down isotope-based observational constraints is favorably combined with bottom-up emission inventories to iteratively produce an improved understanding of both anthropogenic sources and atmospheric behavior of climate- and health-afflicting carbonaceous aerosols in the air of South and East Asia.

  6. New normative standards of conditional reasoning and the dual-source model

    PubMed Central

    Singmann, Henrik; Klauer, Karl Christoph; Over, David

    2014-01-01

    There has been a major shift in research on human reasoning toward Bayesian and probabilistic approaches, which has been called a new paradigm. The new paradigm sees most everyday and scientific reasoning as taking place in a context of uncertainty, and inference is from uncertain beliefs and not from arbitrary assumptions. In this manuscript we present an empirical test of normative standards in the new paradigm using a novel probabilized conditional reasoning task. Our results indicated that for everyday conditional with at least a weak causal connection between antecedent and consequent only the conditional probability of the consequent given antecedent contributes unique variance to predicting the probability of conditional, but not the probability of the conjunction, nor the probability of the material conditional. Regarding normative accounts of reasoning, we found significant evidence that participants' responses were confidence preserving (i.e., p-valid in the sense of Adams, 1998) for MP inferences, but not for MT inferences. Additionally, only for MP inferences and to a lesser degree for DA inferences did the rate of responses inside the coherence intervals defined by mental probability logic (Pfeifer and Kleiter, 2005, 2010) exceed chance levels. In contrast to the normative accounts, the dual-source model (Klauer et al., 2010) is a descriptive model. It posits that participants integrate their background knowledge (i.e., the type of information primary to the normative approaches) and their subjective probability that a conclusion is seen as warranted based on its logical form. Model fits showed that the dual-source model, which employed participants' responses to a deductive task with abstract contents to estimate the form-based component, provided as good an account of the data as a model that solely used data from the probabilized conditional reasoning task. PMID:24860516

  7. New normative standards of conditional reasoning and the dual-source model.

    PubMed

    Singmann, Henrik; Klauer, Karl Christoph; Over, David

    2014-01-01

    There has been a major shift in research on human reasoning toward Bayesian and probabilistic approaches, which has been called a new paradigm. The new paradigm sees most everyday and scientific reasoning as taking place in a context of uncertainty, and inference is from uncertain beliefs and not from arbitrary assumptions. In this manuscript we present an empirical test of normative standards in the new paradigm using a novel probabilized conditional reasoning task. Our results indicated that for everyday conditional with at least a weak causal connection between antecedent and consequent only the conditional probability of the consequent given antecedent contributes unique variance to predicting the probability of conditional, but not the probability of the conjunction, nor the probability of the material conditional. Regarding normative accounts of reasoning, we found significant evidence that participants' responses were confidence preserving (i.e., p-valid in the sense of Adams, 1998) for MP inferences, but not for MT inferences. Additionally, only for MP inferences and to a lesser degree for DA inferences did the rate of responses inside the coherence intervals defined by mental probability logic (Pfeifer and Kleiter, 2005, 2010) exceed chance levels. In contrast to the normative accounts, the dual-source model (Klauer et al., 2010) is a descriptive model. It posits that participants integrate their background knowledge (i.e., the type of information primary to the normative approaches) and their subjective probability that a conclusion is seen as warranted based on its logical form. Model fits showed that the dual-source model, which employed participants' responses to a deductive task with abstract contents to estimate the form-based component, provided as good an account of the data as a model that solely used data from the probabilized conditional reasoning task.

  8. Investigation of a dual-isotope approach to trace nitrate sources in groundwater systems

    NASA Astrophysics Data System (ADS)

    Fukada, T.; Hiscock, K. M.; Dennis, P. F.

    2002-12-01

    Nitrate contamination in groundwater has long been an issue in Europe, with reported high nitrate concentrations in drinking water of greater than 10 mg/L NO3-N, as defined by the World Health Organisation, posing various health risks. Identifying the sources and fate of nitrate in groundwater is part of the solution to nitrate contamination. Several methods have been reported for identifying nitrogen sources, such as the single isotope method using the nitrogen isotopes of nitrate, but the methods present difficulties, such as ambiguity of interpretation. In this study, and by adopting a dual-isotope approach, with measurements of oxygen as well as nitrogen isotopes of nitrate, we have been able to identify the sources and fate of nitrate in groundwater with greater confidence. To investigate the approach, we collected groundwater samples from a Pleistocene alluvial aquifer at a bank filtration site in Germany, the Cretaceous Chalk aquifer in rural eastern England, the Triassic sandstone aquifer in the urban English Midlands and also from controlled laboratory columns treated with pig manure. The values of nitrogen isotopes in groundwater nitrate sources were in the range of -0.13 to +5.64 % for inorganic fertiliser, +9.26 to +11.44 % for urban sewerage and +8.99 to +13.61 % for pig manure. Values of the oxygen isotopes in groundwater nitrate sources were in the range of +3.46 to +16.00 % for inorganic fertiliser, +8.21to +10.77 % for sewerage and +10.73 to +12.07 % for pig manure. We also observed that those sites experiencing denitrification produced a linear relationship indicating an enrichment of the heavier nitrogen isotope relative to the heavier oxygen isotope by a factor of 1.3 and 1.9.

  9. Single- and dual-energy CT of the abdomen: comparison of radiation dose and image quality of 2nd and 3rd generation dual-source CT.

    PubMed

    Wichmann, Julian L; Hardie, Andrew D; Schoepf, U Joseph; Felmly, Lloyd M; Perry, Jonathan D; Varga-Szemes, Akos; Mangold, Stefanie; Caruso, Damiano; Canstein, Christian; Vogl, Thomas J; De Cecco, Carlo N

    2017-02-01

    To compare single-energy (SECT) and dual-energy (DECT) abdominal CT examinations in matched patient cohorts regarding differences in radiation dose and image quality performed with second- and third-generation dual-source CT (DSCT). We retrospectively analysed 200 patients (100 male, 100 female; mean age 61.2 ± 13.5 years, mean body mass index 27.5 ± 3.8 kg/m(2)) equally divided into four groups matched by gender and body mass index, who had undergone portal venous phase abdominal CT with second-generation (group A, 120-kV-SECT; group B, 80/140-kV-DECT) and third-generation DSCT (group C, 100-kV-SECT; group D, 90/150-kV-DECT). The radiation dose was normalised for 40-cm scan length. Dose-independent figure-of-merit (FOM) contrast-to-noise ratios (CNRs) were calculated for various organs and vessels. Subjective overall image quality and reader confidence were assessed. The effective normalised radiation dose was significantly lower (P < 0.001) in groups C (6.2 ± 2.0 mSv) and D (5.3 ± 1.9 mSv, P = 0.103) compared to groups A (8.8 ± 2.3 mSv) and B (9.7 ± 2.4 mSv, P = 0.102). Dose-independent FOM-CNR peaked for liver, kidney, and portal vein measurements (all P ≤ 0.0285) in group D. Subjective image quality and reader confidence were consistently rated as excellent in all groups (all ≥1.53 out of 5). With both DSCT generations, abdominal DECT can be routinely performed without radiation dose penalty compared to SECT, while third-generation DSCT shows improved dose efficiency. • Dual-source CT (DSCT) allows for single- and dual-energy image acquisition. • Dual-energy acquisition does not increase the radiation dose in abdominal DSCT. • Third-generation DSCT shows improved dose efficiency compared to second-generation DSCT. • Dose-independent figure-of-merit image contrast was highest with third-generation dual-energy DSCT. • Third-generation DSCT shows improved dose efficiency for SECT and DECT.

  10. Correlation Between Dual-energy and Perfusion CT in Patients with Focal Liver Lesions Using Third-generation Dual-source CT Scanner.

    PubMed

    Xu, Jia; Zheng, Yongchang; Wang, Xuan; Xue, Huadan; Wang, Shitian; Liang, Jixiang; Jin, Zhengyu

    2017-02-20

    Objective To compare measurements of dual-energy CT iodine map parameters and liver perfusion CT parameters in patients with focal liver lesions using a third-generation dual-source CT scanner. Methods Between November 2015 and August 2016,33 patients with non-cystic focal lesions of liver were enrolled in this study. CT examinations were performed with a third-generation dual-source CT. The study CT protocol included a perfusion CT and dual-energy arterial and portal venous scans,with a time interval of 15 minutes. Iodine attenuation was measured at five region of interests including areas of high,medium,and low density within the lesion,as well as right and left liver parenchyma from the iodine map,while arterial liver perfusion (ALP),portal venous liver perfusion (PVP),and hepatic perfusion index (HPI) at the same location were measured from perfusion CT. The Pearson product-moment correlation coefficient was used to evaluate the relationship between iodine attenuation and perfusion parameters. Results The iodine attenuation at arterial phase showed significant intra-individual correlation with ALP (r=0.812,95% CI=0.728-0.885,P<0.001)and PVP (r=-0.209,95% CI=-0.323--0.073,P=0.007),but not significantly correlated with HPI (r=0.058,95% CI=0.046-0.498,P=0.461). The iodine attenuation at portal venous phase showed significant correlation with PVP (r=0.214,95% CI=0.072-0.361,P=0.005) but not with HPI(r=0.036,95% CI=-0.002-0.242,P=0.649). The mean effective dose of arterial phase and portal venous phase of dual-energy CT together [(3.53±1.17)mSv] was significantly lower than that of the perfusion CT [(14.53±0.45)mSv](t=25.212,P<0.001). Conclusion Iodine attenuation from arterial phase of dual energy CT demonstrates significant correlation with ALP and PVP,and iodine attenuation from portal venous phase demonstrates significant correlation with PVP.

  11. Quantitative analysis of motion artifacts in high-pitch dual-source computed tomography of the thorax.

    PubMed

    Schulz, Boris; Jacobi, Volkmar; Beeres, Martin; Bodelle, Boris; Gruber, Tatjana; Lee, Clara; Bauer, Ralf; Kerl, Matthias; Vogl, Thomas; Zangos, Stefan

    2012-11-01

    The purpose of this study was to objectively analyze motion artifacts on thoracic computed tomography (CT) with dual-source high-pitch and single-source techniques when using a no-breath-hold technique to examine patients who have difficulty complying with breath-holding instructions. A total of 120 patients who received CT of the thorax with a free-breathing technique in single-source (16 slices and 128 slices; pitch = 1.2) and dual-source (pitch = 3.0) manners were evaluated retrospectively. In each of the 3 study groups, movements of the diaphragm and pulsations of the aortic root and main pulmonary artery were analyzed for their number and severity (blurred distance). No motion artifacts of the diaphragm were identified using a pitch of 3.0 (compared with n = 14 for single-source CT using 128 slices and n = 24 using 16-slice CT). In single-source examinations, the severity of artifacts was similar between 128-slice CT and 16-slice CT: blurring distance of the lung parenchyma due to diaphragm movements was 14 versus 16 mm, and double contours of the aorta were measured as 8 and 9 mm, respectively. A high-pitch, dual-source mode is potentially advantageous for evaluating the lung parenchyma and vascular structures in patients who have difficulty complying with breath-holding instructions. Increasing from 16 to 128 slices can significantly reduce the number and severity of motion artifacts.

  12. Tube Current Modulation Between Single- and Dual-Energy CT With a Second-Generation Dual-Source Scanner: Radiation Dose and Image Quality.

    PubMed

    Matsubara, Kosuke; Takata, Tadanori; Kobayashi, Masanao; Kobayashi, Satoshi; Koshida, Kichiro; Gabata, Toshifumi

    2016-08-01

    The purpose of this study was to compare the effects of tube current modulation between single- and dual-energy CT with a second-generation dual-source scanner. Custom-made elliptic polymethylmethacrylate phantoms for slim and large patients were used. Absorbed radiation dose at the central point of the phantoms was measured with a solid-state detector while the phantoms were scanned in single-energy (120 kV) and dual-energy (100/Sn140, 80/Sn140, and 140/80 kV) modes with a second-generation dual-source CT scanner. Tube current modulation was activated in both modes, and quality reference tube current-time settings of 150, 300, 450, and 600 mAs were selected. Scanning was performed three times under the same conditions, and image noise was evaluated by measuring the SD of CT numbers in four separate regions of three adjacent images of the phantoms. Absorbed dose increased and image noise decreased with an increase in quality reference tube current-time setting when the slim phantom was scanned. For the large phantom, the radiation dose and noise level reached a plateau above quality reference tube current-time settings of 300 mAs for 100/Sn140 kV and 450 mAs for 120 kV. The radiation dose was small and the noise level was large with 80/Sn140 kV compared with that obtained with 120 and 100/Sn140 kV at all quality reference tube current-time settings. When a large phantom is scanned with 100/Sn140 kV, exposure demand for tube current modulation exceeds system limits at a lower quality reference tube current-time setting than for scanning 120 kV.

  13. An insight into the western Pacific wintertime moisture sources using dual water vapor isotopes

    NASA Astrophysics Data System (ADS)

    Rangarajan, Ravi; Laskar, Amzad H.; Bhattacharya, Sourendra K.; Shen, Chuan-Chou; Liang, Mao-Chang

    2017-04-01

    Continuous measurements of isotopic ratios in atmospheric water vapor in a western Pacific region (Taipei, Taiwan) in two winters (2011 and 2012) were made and analyzed to understand the moisture source characteristics. In wintertime, the so-called East Asian Monsoon dominates, largely affecting the climate and meteorology of this region. Being located in the subtropical region, Taipei provides an ideal opportunity for studying interactions between high latitude cold and dry continental air masses and low to mid-latitude warm and wet oceanic air. Indeed, the dual isotope function, d-excess shows the presence of two distinct moisture sources, contributing to the winter vapor isotope variability. Undoubtedly, the dominant moisture source is the high latitude continental cold air masses reaching Taipei with d-excess values of >20‰. Alongside, wet and warm air masses characterized by strong air-sea interaction from the surrounding oceans, possessing d-excess value of ∼10‰ also play a role. The interactions of these two distinct air masses cause the d-excess values to change by as much as ∼20‰ in a few days. Multiple regression analysis shows that source moisture composition and water vapor mixing ratio combined control over 60% of the observed variability. We developed a box model to show that both high and low d-excess events in the winter are primarily controlled by the humidity deficit over the ocean. The information obtained in this study could be used in interpreting the paleoclimate proxies within the East Asian region.

  14. Dual-Source Linear Energy Prediction (LINE-P) Model in the Context of WSNs

    PubMed Central

    Ahmed, Faisal

    2017-01-01

    Energy harvesting technologies such as miniature power solar panels and micro wind turbines are increasingly used to help power wireless sensor network nodes. However, a major drawback of energy harvesting is its varying and intermittent characteristic, which can negatively affect the quality of service. This calls for careful design and operation of the nodes, possibly by means of, e.g., dynamic duty cycling and/or dynamic frequency and voltage scaling. In this context, various energy prediction models have been proposed in the literature; however, they are typically compute-intensive or only suitable for a single type of energy source. In this paper, we propose Linear Energy Prediction “LINE-P”, a lightweight, yet relatively accurate model based on approximation and sampling theory; LINE-P is suitable for dual-source energy harvesting. Simulations and comparisons against existing similar models have been conducted with low and medium resolutions (i.e., 60 and 22 min intervals/24 h) for the solar energy source (low variations) and with high resolutions (15 min intervals/24 h) for the wind energy source. The results show that the accuracy of the solar-based and wind-based predictions is up to approximately 98% and 96%, respectively, while requiring a lower complexity and memory than the other models. For the cases where LINE-P’s accuracy is lower than that of other approaches, it still has the advantage of lower computing requirements, making it more suitable for embedded implementation, e.g., in wireless sensor network coordinator nodes or gateways. PMID:28726745

  15. Dual-Source Linear Energy Prediction (LINE-P) Model in the Context of WSNs.

    PubMed

    Ahmed, Faisal; Tamberg, Gert; Le Moullec, Yannick; Annus, Paul

    2017-07-20

    Energy harvesting technologies such as miniature power solar panels and micro wind turbines are increasingly used to help power wireless sensor network nodes. However, a major drawback of energy harvesting is its varying and intermittent characteristic, which can negatively affect the quality of service. This calls for careful design and operation of the nodes, possibly by means of, e.g., dynamic duty cycling and/or dynamic frequency and voltage scaling. In this context, various energy prediction models have been proposed in the literature; however, they are typically compute-intensive or only suitable for a single type of energy source. In this paper, we propose Linear Energy Prediction "LINE-P", a lightweight, yet relatively accurate model based on approximation and sampling theory; LINE-P is suitable for dual-source energy harvesting. Simulations and comparisons against existing similar models have been conducted with low and medium resolutions (i.e., 60 and 22 min intervals/24 h) for the solar energy source (low variations) and with high resolutions (15 min intervals/24 h) for the wind energy source. The results show that the accuracy of the solar-based and wind-based predictions is up to approximately 98% and 96%, respectively, while requiring a lower complexity and memory than the other models. For the cases where LINE-P's accuracy is lower than that of other approaches, it still has the advantage of lower computing requirements, making it more suitable for embedded implementation, e.g., in wireless sensor network coordinator nodes or gateways.

  16. Myocardial ischemia evaluation with dual-source computed tomography: comparison with magnetic resonance imaging.

    PubMed

    Delgado, Carlos; Vázquez, María; Oca, Roque; Vilar, Manuel; Trinidad, Carmen; Sanmartin, Marcelo

    2013-11-01

    Computed tomography does not accurately determine which coronary lesions lead to myocardial ischemia and consequently further tests are required to evaluate ischemia induction. The aim of this study was to compare diagnostic accuracy between dual-energy computed tomography and magnetic resonance imaging in the assessment of myocardial perfusion and viability in patients suspected of coronary artery disease. A prospective study was performed in 56 consecutive patients (39 men [69.6%]; mean age [standard deviation], 63 [10]; range, 23-81). Computed tomography was performed with the following protocol: 1, adenosine stress perfusion; 2, coronary angiography; and 3, delayed enhancement. Magnetic resonance imaging for the evaluation of stress perfusion and delayed enhancement was performed within 30 days. Two observers in consensus analyzed the perfusion and delayed enhancement images. We studied 952 myocardial segments and 168 vascular territories. In a per-segment analysis, the sensitivity, specificity, and positive and negative predictive values of computed tomography compared with magnetic resonance were 76%, 99%, 89%, and 98% for perfusion defects, and 64%, 99%, 82%, and 99% for delayed enhancement, respectively. In a per-vascular territory analysis, the same measures were 78%, 97%, 86%, and 95% for perfusion defects, and 72%, 99%, 93%, and 97% for delayed enhancement, respectively. The mean radiation dose was 8.2 (2) mSv. Dual-source computed tomography may allow accurate and concomitant evaluation of perfusion defects and myocardial viability and analysis of coronary anatomy. Copyright © 2013 Sociedad Española de Cardiología. Published by Elsevier Espana. All rights reserved.

  17. Material differentiation in forensic radiology with single-source dual-energy computed tomography.

    PubMed

    Ruder, Thomas D; Thali, Yannick; Bolliger, Stephan A; Somaini-Mathier, Sandra; Thali, Michael J; Hatch, Gary M; Schindera, Sebastian T

    2013-06-01

    The goal of this study was to investigate the use of dual-energy computed tomography (CT) in differentiating frequently encountered foreign material on CT images using a standard single-source CT scanner. We scanned 20 different, forensically relevant materials at two X-Ray energy levels (80 and 130 kVp) on CT. CT values were measured in each object at both energy levels. Intraclass correlation coefficient (ICC) was used to determine intra-reader reliability. Analysis of variance (ANOVA) was performed to assess significance levels between X-Ray attenuation at 80 and 130 kVp. T test was used to investigate significance levels between mean HU values of individual object pairings at single energy levels of 80 and 130 kVp, respectively. ANOVA revealed that the difference in attenuation between beam energies of 80 kVp compared to 130 kVp was statistically significant (p < 0.005) for all materials except brass and lead. ICC was excellent at 80 kVp (0.999, p < 0.001) and at 130 kVp (0.998, p < 0.001). T test showed that using single energy levels of 80 and 130 kVp respectively 181/190 objects pairs could be differentiated from one another based on HU measurements. Using the combined information from both energy levels, 189/190 object pairs could be differentiated. Scanning with different energy levels is a simple way to apply dual-energy technique on a regular single-energy CT and improves the ability to differentiate foreign bodies with CT, based on their attenuation values.

  18. Dual-energy quasi-monochromatic x-ray source development

    NASA Astrophysics Data System (ADS)

    Richardson, Jonathan M.

    2004-05-01

    There many instances where the use of a quasi-monochromatic x ray source (QMS) would be an advantage in radiology. One instance is dual-energy imaging, where two images may be processed in order to enhance visualization of a particular element, typically iodine, but also possibly gadolinium. Another instance is fluoroscopy, where the radiation and/or contrast doses may be minimized by using a radiation source with an energy peak that lies just above the contrast K edge. The most straightforward method of implementing a QMS is to incorporate appropriate heavy elements into an x ray tube anode and then to filter the resulting spectrum appropriately. Science Research Laboratory, Inc. has embarked on a program to develop anode materials that can withstand the power loadings encountered in a useful tube. Thus far, we have developed and tested one relevant anode material (erbia) and demonstrated that it could withstand a power of 0.25 MW/cm2 at a tip speed of 3300cm/sec without harm. The destructive limit was determined to be at least a factor of two higher due to overwriting of the electron beam in certain regions. Under the condition of no overwriting, coating survivability should scale directly with tip speed. For futures studies we have designed an apparatus that increases the tip speed by a factor of 4.8. In the longer term, the tip speed could be increased by as much as a factor of 20.

  19. Study of 1 MW neutron source synchrotron dual frequency power circuit for the main ring magnets

    SciTech Connect

    McGhee, D.G.

    1993-07-01

    This paper describes the proposed design of the resonant power circuits for the 1-MW neutron source synchrotron`s main ring magnets. The synchrotron is to have a duty cycle of 30 Hz with a maximum upper limit of operation corresponding to 2.0 GeV and a maximum design value of 2.2 GeV. A stability of 30 ppM is the design goal for the main bending and focusing magnets (dipoles and quadruples), in order to achieve an overall stabffity of 100 ppm when random field and position errors of the magnets are included. The power circuits of this design are similar to those used in Argonne`s Intense Pulsed Neutron Source (IPNS) where the energy losses during each cycle are supplied by continuous excitation from modulated multiphase DC power supplies. Since only 50% of the 30-Hz sinewave is used for acceleration, a dual-frequency resonant magnet circuit is used in this design. The 30-Hz repetition rate is maintained with a 20-Hz magnet guide field during acceleration and a 60-Hz reset field when no beam is present. This lengthens the guide-field rise time and shortens the fall time, improving the duty factor for acceleration. The maximum B dot is reduced by 33% during acceleration and hence, the maximum rf voltage/turn is reduced by 56%.

  20. Detecting Intracranial Hemorrhage Using Automatic Tube Current Modulation With Advanced Modeled Iterative Reconstruction in Unenhanced Head Single- and Dual-Energy Dual-Source CT.

    PubMed

    Scholtz, Jan-Erik; Wichmann, Julian L; Bennett, Dennis W; Leithner, Doris; Bauer, Ralf W; Vogl, Thomas J; Bodelle, Boris

    2017-05-01

    The purpose of our study was to determine diagnostic accuracy, image quality, and radiation dose of low-dose single- and dual-energy unenhanced third-generation dual-source head CT for detection of intracranial hemorrhage (ICH). A total of 123 patients with suspected ICH were examined using a dual-source 192-MDCT scanner. Standard-dose 120-kVp single-energy CT (SECT; n = 36) and 80-kVp and 150-kVp dual-energy CT (DECT; n = 30) images were compared with low-dose SECT (n = 32) and DECT (n = 25) images obtained using automated tube current modulation (ATCM). Advanced modeled iterative reconstruction (ADMIRE) was used for all protocols. Detection of ICH was performed by three readers who were blinded to the image acquisition parameters of each image series. Image quality was assessed both quantitatively and qualitatively. Interobserver agreement was calculated using the Fleiss kappa. Radiation dose was measured as dose-length product (DLP). Detection of ICH was excellent (sensitivity, 94.9-100%; specificity, 94.7-100%) in all protocols (p = 1.00) with perfect interobserver agreement (0.83-0.96). Qualitative ratings showed significantly better ratings for both standard-dose protocols regarding gray matter-to-white matter contrast (p ≤ 0.014), whereas highest gray matter-to-white matter contrast-to-noise ratio was observed with low-dose DECT images (p ≥ 0.057). The lowest posterior fossa artifact index was measured for standard-dose DECT, which showed significantly lower values compared with low-dose protocols (p ≤ 0.034). Delineation of ventricular margins and sharpness of subarachnoidal spaces were rated excellent in all protocols (p ≥ 0.096). Low-dose techniques lowered radiation dose by 26% for SECT images (DLP, 575.0 ± 72.3 mGy · cm vs 771.5 ± 146.8 mGy · cm; p < 0.001) and by 24% in DECT images (DLP, 587.0 ± 103.2 mGy · cm vs 770.6 ± 90.2 mGy · cm; p < 0.001). No significant difference was observed between the low-dose protocols (p = 1.00). Low

  1. Electrocortical Sources Related to Whole-Body Surface Translations during a Single- and Dual-Task Paradigm

    PubMed Central

    Bogost, Mark D.; Burgos, Pablo I.; Little, C. Elaine; Woollacott, Marjorie H.; Dalton, Brian H.

    2016-01-01

    Appropriate reactive motor responses are essential in maintaining upright balance. However, little is known regarding the potential location of cortical sources that are related to the onset of a perturbation during single- and dual-task paradigms. The purpose of this study was to estimate the location of cortical sources in response to a whole-body surface translation and whether diverted attention decreases the N1 event-related potential (ERP) amplitude related to a postural perturbation. This study utilized high-resolution electroencephalography in conjunction with measure projection analysis from ERPs time-locked to backwards surface translation onsets to determine which cortical sources were related to whole-body postural perturbations. Subjects (n = 15) either reacted to whole-body surface translations with (dual task) or without (single task) performing a visual working memory task. For the single task, four domains were identified that were mainly localized within the frontal and parietal lobes and included sources from the prefrontal, premotor, primary and supplementary motor, somatosensory and anterior cingulate cortex. Five domains were estimated for the dual task and also included sources within the frontal and parietal lobes, but the sources also shifted to other locations that included areas within the temporal and occipital lobes. Additionally, mean absolute N1 ERP amplitudes representing the activity from similar locations in both tasks were greater for the single than dual task. The present localization results highlight the importance of frontal, parietal and anterior cingulate cortical areas in reactive postural control and suggest a re-allocation or shift of cortical sources related to reactive balance control in the presence of a secondary task. Thus, this study provides novel insight into the underlying neurophysiology and contribution of cortical sources in relation to the neural control of reactive balance. PMID:27803658

  2. Electrocortical Sources Related to Whole-Body Surface Translations during a Single- and Dual-Task Paradigm.

    PubMed

    Bogost, Mark D; Burgos, Pablo I; Little, C Elaine; Woollacott, Marjorie H; Dalton, Brian H

    2016-01-01

    Appropriate reactive motor responses are essential in maintaining upright balance. However, little is known regarding the potential location of cortical sources that are related to the onset of a perturbation during single- and dual-task paradigms. The purpose of this study was to estimate the location of cortical sources in response to a whole-body surface translation and whether diverted attention decreases the N1 event-related potential (ERP) amplitude related to a postural perturbation. This study utilized high-resolution electroencephalography in conjunction with measure projection analysis from ERPs time-locked to backwards surface translation onsets to determine which cortical sources were related to whole-body postural perturbations. Subjects (n = 15) either reacted to whole-body surface translations with (dual task) or without (single task) performing a visual working memory task. For the single task, four domains were identified that were mainly localized within the frontal and parietal lobes and included sources from the prefrontal, premotor, primary and supplementary motor, somatosensory and anterior cingulate cortex. Five domains were estimated for the dual task and also included sources within the frontal and parietal lobes, but the sources also shifted to other locations that included areas within the temporal and occipital lobes. Additionally, mean absolute N1 ERP amplitudes representing the activity from similar locations in both tasks were greater for the single than dual task. The present localization results highlight the importance of frontal, parietal and anterior cingulate cortical areas in reactive postural control and suggest a re-allocation or shift of cortical sources related to reactive balance control in the presence of a secondary task. Thus, this study provides novel insight into the underlying neurophysiology and contribution of cortical sources in relation to the neural control of reactive balance.

  3. Dual diagnosis, as described by those who experience the disorder: using the Internet as a source of data.

    PubMed

    Edward, Karen-Leigh; Robins, Alan

    2012-12-01

    The complexity of providing treatment for people with dual diagnosis is well recognized. For the purpose of this paper, the World Health Organization definition of dual diagnosis was used; that is, a person diagnosed with an alcohol or drug use problem in addition to mental illness. This research explored the personal narratives of those who experience dual diagnosis using the Internet as a data source. An important consideration in using the Internet as a data source was that Web forums can offer a sense of anonymity, allowing people to share very detailed and personal information, and providing a rich source of qualitative data. The results produced five emergent themes: spiralling out of control - again!, getting help and giving support, treating both the addiction and mental illness, having meaning and being active, and being honest with self and others. The results indicate that individuals who experience dual diagnosis are often left to navigate their personal treatment requirements across two diverse systems, and were generally not satisfied with the conflictual advice received across these two systems (i.e. alcohol and other drug and mental health services). This study has produced valuable insights related to consumer-perceived service barriers and enablers.

  4. Dual-source dual-energy CT angiography with virtual non-enhanced images and iodine map for active gastrointestinal bleeding: image quality, radiation dose and diagnostic performance.

    PubMed

    Sun, Hao; Hou, Xin-Yi; Xue, Hua-Dan; Li, Xiao-Guang; Jin, Zheng-Yu; Qian, Jia-Ming; Yu, Jian-Chun; Zhu, Hua-Dong

    2015-05-01

    To evaluate the clinical feasibility of dual-source dual-energy CT angiography (DSDECTA) with virtual non-enhanced images and iodine map for active gastrointestinal bleeding (GIB). From June 2010 to December 2012, 112 consecutive patients with clinical signs of active GIB underwent DSDECTA with true non-enhanced (TNE), arterial phase with single-source mode, and portal-venous phase with dual-energy mode (100 kVp/230 mAs and Sn 140 kVp/178 mAs). Virtual non-enhanced CT (VNE) image sets and iodine map were reformatted from 'Liver VNC' software. The mean CT number, noise, signal to noise ratio (SNR), image quality and radiation dose were compared between TNE and VNE image sets. Two radiologists, blinded to clinical data, interpreted images from DSDECTA with TNE (protocol 1), and DSDECTA with VNE and iodine map (protocol 2) respectively, with discordant interpretation resolved by consensus. The standards of reference included digital subtraction angiography, endoscopy, surgery, or final pathology reports. Receiver-operating characteristic (ROC) analysis was undertaken and the area under the curve (AUC) calculated for CT protocols 1 and 2, respectively. There was no significant difference in mean CT numbers of all organs (including liver, pancreas, spleen, kidney, abdominal aorta, and psoas muscle) (P>0.05). Lower noise and higher SNR were found on VNE images than TNE images (P<0.05). Image quality of VNE was lower than that of TNE without significant difference (P>0.05). The active GIB source was identified in 84 patients, 83 (83/84, 98.8%) of which were confirmed by one or more reference standard. The AUC was 0.935±0.027 and 0.947±0.026 for protocols 1 and 2, respectively. There was no significant difference between protocols 1 and 2 for diagnostic performance (Z=1.672, P>0.05). The radiation dose reduction achieved by omitting the TNE acquisition was (30.11±6.32)%. DSDECTA with arterial phase with single-source mode, portal-venous phase with dual-energy mode and

  5. [Determination of iodine content in the left ventricular myocardium of healthy subjects using dual-source dual-energy CT myocardial first perfusion imaging: a preliminary study].

    PubMed

    Chen, Z X; Wang, G; Liang, L; Lu, X R; Guo, Q H; Zhai, Y N; Shi, X N

    2017-05-24

    Objective: To analyze the normal value of the iodine content in the left ventricular myocardium of healthy subjects and to observe if there is a segmental differences on iodine distribution by using the second generation dual-source dual-energy computed tomography myocardial first perfusion imaging. Methods: In this retrospective study, 42 healthy subjects, who admitted to our department between January to June 2016, with normal second generation dual-source dual-energy computed tomography and coronary CT angioghphy (CTA), electrocardiogram (ECG) results, normal cardiac, hepatic, renal function, normal myocardial enzymes results were enrolled, data from 38 out of 42 subjects with satisfactory image quality were analyzed using Siemens Dual Energy-Heart PBV image processing software.In accordance with the standards of the American Heart Association myocardial 17 fractionation method, content of iodine was measured at different segmental left ventricular myocardium and aorta (left coronary artery from the opening level). The standardized containing iodine value (nIC) was calculated. Results: The iodine content of left ventricular myocardium in normal subjects was 3.1-7.8 mg/ml.The nIC of myocardium from 1st to 17th segments was 0.28±0.06, 0.31±0.07, 0.30±0.07, 0.30±0.04, 0.28±0.04, 0.29±0.05, 0.29±0.01, 0.30±0.07, 0.31±0.07, 0.27±0.06, 0.28±0.08, 0.28±0.07, 0.29±0.08, 0.31±0.07, 0.27±0.06, 0.29±0.06 and 0.21±0.07, respectively.The nIC of the 17th segment was the lowest and was significantly lower than in other segments (all P<0.05), the nIC was similar among the rest 16 segments (all P>0.05). Conclusion: The normal iodine content range in left ventricle myocardium is 3.1-7.8 mg/ml, and the lowest iodine content is detected in the apex and which is significantly lower than the other left ventricular segments.

  6. Dual-core ytterbium fiber amplifier for high-power 1060 nm swept source multichannel optical coherence tomography imaging.

    PubMed

    Harduar, Mark K; Mariampillai, Adrian; Vuong, Barry; Gu, Xijia; Standish, Beau A; Yang, Victor X D

    2011-08-01

    A novel (to our knowledge) dual-core ytterbium (Yb(3+)) doped fiber, as an optically pumped amplifier, boosts the output power from a 1060 nm swept source laser beyond 250 mW, while providing a wavelength tuning range of 93 nm, for optical coherence tomography (OCT) imaging. The design of the dual-core Yb-doped fiber amplifier and its multiple wavelength optical pumping scheme to optimize output bandwidth are discussed. Use of the dual-core fiber amplifier showed no appreciable degradation to the coherence length of the seed laser. The signal intensity improvement of this amplifier is demonstrated on a multichannel in vivo OCT imaging system at 1060 nm.

  7. Identifying diffused nitrate sources in a stream in an agricultural field using a dual isotopic approach.

    PubMed

    Ding, Jingtao; Xi, Beidou; Gao, Rutai; He, Liansheng; Liu, Hongliang; Dai, Xuanli; Yu, Yijun

    2014-06-15

    Nitrate (NO3(-)) pollution is a severe problem in aquatic systems in Taihu Lake Basin in China. A dual isotope approach (δ(15)NNO3(-) and δ(18)ONO3(-)) was applied to identify diffused NO3(-) inputs in a stream in an agricultural field at the basin in 2013. The site-specific isotopic characteristics of five NO3(-) sources (atmospheric deposition, AD; NO3(-) derived from soil organic matter nitrification, NS; NO3(-) derived from chemical fertilizer nitrification, NF; groundwater, GW; and manure and sewage, M&S) were identified. NO3(-) concentrations in the stream during the rainy season [mean±standard deviation (SD)=2.5±0.4mg/L] were lower than those during the dry season (mean±SD=4.0±0.5mg/L), whereas the δ(18)ONO3(-) values during the rainy season (mean±SD=+12.3±3.6‰) were higher than those during the dry season (mean±SD=+0.9±1.9‰). Both chemical and isotopic characteristics indicated that mixing with atmospheric NO3(-) resulted in the high δ(18)O values during the rainy season, whereas NS and M&S were the dominant NO3(-) sources during the dry season. A Bayesian model was used to determine the contribution of each NO3(-) source to total stream NO3(-). Results showed that reduced N nitrification in soil zones (including soil organic matter and fertilizer) was the main NO3(-) source throughout the year. M&S contributed more NO3(-) during the dry season (22.4%) than during the rainy season (17.8%). AD generated substantial amounts of NO3(-) in May (18.4%), June (29.8%), and July (24.5%). With the assessment of temporal variation of diffused NO3(-) sources in agricultural field, improved agricultural management practices can be implemented to protect the water resource and avoid further water quality deterioration in Taihu Lake Basin.

  8. Sources and transformations of nitrate from streams draining varying land uses: Evidence from dual isotope analysis

    USGS Publications Warehouse

    Burns, Douglas A.; Boyer, E.W.; Elliott, E.M.; Kendall, C.

    2009-01-01

    Knowledge of key sources and biogeochemical processes that affect the transport of nitrate (NO3-) in streams can inform watershed management strategies for controlling downstream eutrophication. We applied dual isotope analysis of NO3- to determine the dominant sources and processes that affect NO3- concentrations in six stream/river watersheds of different land uses. Samples were collected monthly at a range of flow conditions for 15 mo during 2004-05 and analyzed for NO3- concentrations, ?? 15NNO3, and ??18ONO3. Samples from two forested watersheds indicated that NO3- derived from nitrification was dominant at baseflow. A watershed dominated by suburban land use had three ??18ONO3 values greater than +25???, indicating a large direct contribution of atmospheric NO 3- transported to the stream during some high flows. Two watersheds with large proportions of agricultural land use had many ??15NNO3 values greater than +9???, suggesting an animal waste source consistent with regional dairy farming practices. These data showed a linear seasonal pattern with a ??18O NO3:??15NNO3 of 1:2, consistent with seasonally varying denitrification that peaked in late summer to early fall with the warmest temperatures and lowest annual streamflow. The large range of ?? 15NNO3 values (10???) indicates that NO 3- supply was likely not limiting the rate of denitrification, consistent with ground water and/or in-stream denitrification. Mixing of two or more distinct sources may have affected the seasonal isotope patterns observed in these two agricultural streams. In a mixed land use watershed of large drainage area, none of the source and process patterns observed in the small streams were evident. These results emphasize that observations at watersheds of a few to a few hundred km2 may be necessary to adequately quantify the relative roles of various NO 3- transport and process patterns that contribute to streamflow in large basins. Copyright ?? 2009 by the American Society of

  9. Desired lifetime and end-of-life desires across adulthood from 20 to 90: a dual-source information model.

    PubMed

    Lang, Frieder R; Baltes, Paul B; Wagner, Gert G

    2007-09-01

    How long do people want to live, and how does scientific research on aging affect such desires? A dual-source information model proposes that aging expectations and desires are informed differently by two sources: personal experiences on the one hand, and scientific and societal influences on the other. Two studies with independent German national samples explored desires regarding length of life and end of life among adults between the ages of 20 and 90. FINDINGS ARE: First, desired lifetime is consistent at around 85 years with few age differences. Second, experimental induction of good or bad news from research on aging has little effect in Study 1. Third, interest in science has moderating effects on desired lifetime in Study 2. Fourth, there is a high prevalence of a strong desire to control the "when and how" of one's death, although only 11% of the individuals completed a living will. Findings are consistent with the dual-source information model.

  10. Dual electrospray ion source for electron-transfer dissociation on a hybrid linear ion trap-orbitrap mass spectrometer.

    PubMed

    Williams, D Keith; McAlister, Graeme C; Good, David M; Coon, Joshua J; Muddiman, David C

    2007-10-15

    A dual electrospray ionization source (ESI) has been modified to simultaneously produce cations and anions, one from each emitter, for performing rapid electron-transfer dissociation (ETD) ion/ion reactions on a hybrid linear ion trap-orbitrap mass spectrometer. Unlike the pulsed dual ESI sources that were used to generate ETD reagent ions, this source separates the emitters in space, rather than time, by physically switching which one is in front of the atmospheric inlet. The new arrangement allows for substantially enhanced spray stability and decreased switching times (

  11. Dual-band optical coherence tomography using a single supercontinuum laser source

    NASA Astrophysics Data System (ADS)

    Chen, Siyu; Shu, Xiao; Yi, Ji; Fawzi, Amani; Zhang, Hao F.

    2016-06-01

    We developed a simultaneous visible-light (Vis) and near-infrared (NIR) dual-band optical coherence tomography (OCT) system using a single supercontinuum laser source. The goal was to benchmark our newly developed Vis-OCT against the well-developed NIR-OCT. The Vis-OCT subsystem operated at 91 nm full-width-at-half-maximum (FWHM) bandwidth centered at 566 nm the NIR-OCT subsystem operated at 93 nm FWHM bandwidth centered at 841 nm. The axial resolutions were 1.8 and 4.4 μm in air for the Vis- and NIR-OCT subsystems, respectively. We compared the respective performances, including anatomical imaging, angiography, absolute retinal blood flow measurements, and spectroscopic analysis for retinal blood oxygen saturation (sO2), between the two subsystems in rodents in vivo. While demonstrating minor discrepancies related to operation wavelengths, both subsystems showed comparable performances in the first three tests. However, we were only able to retrieve sO2 using the Vis-OCT subsystem.

  12. Dose heterogeneity correction for low-energy brachytherapy sources using dual-energy CT images

    NASA Astrophysics Data System (ADS)

    Mashouf, S.; Lechtman, E.; Lai, P.; Keller, B. M.; Karotki, A.; Beachey, D. J.; Pignol, J. P.

    2014-09-01

    Permanent seed implant brachytherapy is currently used for adjuvant radiotherapy of early stage prostate and breast cancer patients. The current standard for calculation of dose around brachytherapy sources is based on the AAPM TG-43 formalism, which generates the dose in a homogeneous water medium. Recently, AAPM TG-186 emphasized the importance of accounting for tissue heterogeneities. We have previously reported on a methodology where the absorbed dose in tissue can be obtained by multiplying the dose, calculated by the TG-43 formalism, by an inhomogeneity correction factor (ICF). In this work we make use of dual energy CT (DECT) images to extract ICF parameters. The advantage of DECT over conventional CT is that it eliminates the need for tissue segmentation as well as assignment of population based atomic compositions. DECT images of a heterogeneous phantom were acquired and the dose was calculated using both TG-43 and TG-43 × \\text{ICF} formalisms. The results were compared to experimental measurements using Gafchromic films in the mid-plane of the phantom. For a seed implant configuration of 8 seeds spaced 1.5 cm apart in a cubic structure, the gamma passing score for 2%/2 mm criteria improved from 40.8% to 90.5% when ICF was applied to TG-43 dose distributions.

  13. Dose heterogeneity correction for low-energy brachytherapy sources using dual-energy CT images.

    PubMed

    Mashouf, S; Lechtman, E; Lai, P; Keller, B M; Karotki, A; Beachey, D J; Pignol, J P

    2014-09-21

    Permanent seed implant brachytherapy is currently used for adjuvant radiotherapy of early stage prostate and breast cancer patients. The current standard for calculation of dose around brachytherapy sources is based on the AAPM TG-43 formalism, which generates the dose in a homogeneous water medium. Recently, AAPM TG-186 emphasized the importance of accounting for tissue heterogeneities. We have previously reported on a methodology where the absorbed dose in tissue can be obtained by multiplying the dose, calculated by the TG-43 formalism, by an inhomogeneity correction factor (ICF). In this work we make use of dual energy CT (DECT) images to extract ICF parameters. The advantage of DECT over conventional CT is that it eliminates the need for tissue segmentation as well as assignment of population based atomic compositions. DECT images of a heterogeneous phantom were acquired and the dose was calculated using both TG-43 and TG-43 [Formula: see text] formalisms. The results were compared to experimental measurements using Gafchromic films in the mid-plane of the phantom. For a seed implant configuration of 8 seeds spaced 1.5 cm apart in a cubic structure, the gamma passing score for 2%/2 mm criteria improved from 40.8% to 90.5% when ICF was applied to TG-43 dose distributions.

  14. Simultaneous dual-band spectral domain optical coherence tomography using a supercontinuum laser light source

    NASA Astrophysics Data System (ADS)

    Cimalla, Peter; Mehner, Mirko; Cuevas, Maximiliano; Walther, Julia; Koch, Edmund

    2009-07-01

    Optical coherence tomography (OCT) is performed in the spectral domain simultaneously at two different wavelength bands centered at 800 nm and 1250 nm. A novel commercial supercontinuum laser is applied as a single light source whose emission spectrum is shaped by optical and spatial filtering to obtain an adequate double peak spectrum. After spectral shaping, the wavelength bands 700 - 900 nm and 1100 - 1400 nm are used for OCT imaging. A fiber-coupled setup optimized for both spectral regions facilitates easy and flexible access to the measurement area. Each wavelength band is analyzed with an individual spectrometer at an A-scan rate of about 12 kHz which allows real-time sample examination. The free-space axial resolutions were measured to be less than 4.5 μm and 7 μm at 800 nm and 1250 nm, respectively. This technique combines the high resolution at 800 nm with the enhanced imaging depth at 1250 nm. Furthermore, spatially resolved spectroscopic sample features are extracted by comparing the backscattering properties at the two different wavelength bands, showing the ability of dual-band OCT to enhance image contrast.

  15. [Dual-source computed tomography in inpatients with atypical chest pain].

    PubMed

    Arraiza, M; Arias, J; Broncano, J; Pueyo, J C; Villanueva, A; Bastarrika, G

    2009-01-01

    To evaluate the potential usefulness of dual-source CT (DSCT) in the diagnostic work-up of inpatients with atypical chest pain of unknown etiology. Forty-one consecutive inpatients (25 male, 16 female; mean age 55.6+/-17.39 years) with atypical chest pain underwent DSCT to determine the cause of pain. Images were acquired with retrospective ECG gating after the administration of 120ml of iodinated contrast medium at 4ml/s using the bolus tracking technique. Two readers analyzed the images in consensus. DSCT was diagnostic in all patients. We detected pulmonary embolisms in five patients and aortic disease in two (one aortic ulcer and one sacular aneurysm). Anomalies of the coronary arteries were depicted in 15 patients, two of whom presented luminal stenosis >50%. Extracardiovascular findings at DSCT included pneumonia in eleven patients, sarcoidosis in one, and non-small cell lung carcinoma in one. Pleural effusion was detected in four patients and pericardial effusion in another four. No pathological findings were observed in 22% of subjects. Evolution was favorable in all patients. No patients were readmitted for persistent pain or new onset of acute chest pain during the follow-up period. DSCT can rule out most life-threatening clinical conditions that cause chest pain and is useful in determining the cause of chest pain in inpatients.

  16. Remote picometer fiber Bragg grating demodulation using a dual-wavelength source.

    PubMed

    Clement, Juan; Torregrosa, Germán; Maestre, Haroldo; Fernández-Pousa, Carlos R

    2016-08-10

    We report on the self-referenced, intensity-based, remote and passive interrogation of a fiber Bragg grating (FBG) for point sensing, by use of a reconfigurable dual-wavelength source composed of a tunable wavelength and subsequent suppressed-carrier, electro-optic amplitude modulation. The demodulation procedure is based on the measurement of the reflected power at two different wavelengths within the FBG spectral response. The grating was interrogated by use of conventional spectral analysis, and also after 32.9 km of single-mode fiber using a dispersive incoherent optical Fourier-domain reflectometry technique. Both procedures provide picometer resolution in the determination of Bragg wavelength shifts at a comparatively similar scan time (∼1  s) and received power (-16  dBm). The main limitations in each interrogation scheme have been identified. These results show the feasibility of interrogation systems incorporating relatively simple frequency combs at a calibrated, and eventually reconfigurable, wavelength grid with an, at least, similar performance to that of commercial FBG interrogators.

  17. Dual-Source Precursor Approach for Highly Efficient Inverted Planar Heterojunction Perovskite Solar Cells.

    PubMed

    Luo, Deying; Zhao, Lichen; Wu, Jiang; Hu, Qin; Zhang, Yifei; Xu, Zhaojian; Liu, Yi; Liu, Tanghao; Chen, Ke; Yang, Wenqiang; Zhang, Wei; Zhu, Rui; Gong, Qihuang

    2017-03-15

    The highest efficiencies reported for perovskite solar cells so far have been obtained mainly with methylammonium and formamidinium mixed cations. Currently, high-quality mixed-cation perovskite thin films are normally made by use of antisolvent protocols. However, the widely used "antisolvent"-assisted fabrication route suffers from challenges such as poor device reproducibility, toxic and hazardous organic solvent, and incompatibility with scalable fabrication process. Here, a simple dual-source precursor approach is developed to fabricate high-quality and mirror-like mixed-cation perovskite thin films without involving additional antisolvent process. By integrating the perovskite films into the planar heterojunction solar cells, a power conversion efficiency of 20.15% is achieved with negligible current density-voltage hysteresis. A stabilized power output approaching 20% is obtained at the maximum power point. These results shed light on fabricating highly efficient perovskite solar cells via a simple process, and pave the way for solar cell fabrication via scalable methods in the near future.

  18. Dual-source computed tomography in patients with acute chest pain: feasibility and image quality

    PubMed Central

    Schertler, Thomas; Scheffel, Hans; Frauenfelder, Thomas; Desbiolles, Lotus; Leschka, Sebastian; Stolzmann, Paul; Seifert, Burkhardt; Flohr, Thomas G.; Marincek, Borut

    2007-01-01

    The aim of this study was to determine the feasibility and image quality of dual-source computed tomography angiography (DSCTA) in patients with acute chest pain for the assessment of the lung, thoracic aorta, and for pulmonary and coronary arteries. Sixty consecutive patients (32 female, 28 male, mean age 58.1±16.3 years) with acute chest pain underwent contrast-enhanced electrocardiography-gated DSCTA without prior beta-blocker administration. Vessel attenuation of different thoracic vascular territories was measured, and image quality was semi-quantitatively analyzed by two independent readers. Image quality of the thoracic aorta was diagnostic in all 60 patients, image quality of pulmonary arteries was diagnostic in 59, and image quality of coronary arteries was diagnostic in 58 patients. Pairwise intraindividual comparisons of attenuation values were small and ranged between 1±6 HU comparing right and left coronary artery and 56±9 HU comparing the pulmonary trunk and left ventricle. Mean attenuation was 291±65 HU in the ascending aorta, 334±93 HU in the pulmonary trunk, and 285±66 HU and 268±67 HU in the right and left coronary artery, respectively. DSCTA is feasible and provides diagnostic image quality of the thoracic aorta, pulmonary and coronary arteries in patients with acute chest pain. PMID:17851666

  19. Dual photon absorptiometry using a gadolinium-153 source applied to measure equine bone mineral content

    NASA Astrophysics Data System (ADS)

    Moure, Alessandro; Reichmann, Peter; Remigio Gamba, Humberto

    2003-12-01

    The application of the dual photon absorptiometry (DPA) technique, using gadolinium-153 as the photon source, to evaluate the bone mineral density (BMD) of the third metacarpal bone of horses is presented. The radiation detector was implemented with a NaI(TI) scintillator coupled to a 14 stage photomultiplier. A modular mechanical system allows the position of the prototype to be adjusted in relation to the animal. A moveable carrier makes it possible to scan the third metacarpal with a velocity adjustable between 1 and 12 mm s-1, in steps of 1 mm s-1, for a total distance of 250 mm. The prototype was evaluated with a phantom of the third metacarpal bone made of perspex and aluminium, and in vitro with a transverse slice of the third metacarpal bone of a horse. The tests showed that the prototype has an accuracy and precision of, approximately, 10% and 6%, respectively, for a 6 s acquisition time. Preliminary studies carried out in three foals from birth to one year of age indicated that the prototype is well suited to in vivo and in situ analysis of the BMD of the third metacarpal bones of horses, making it possible to evaluate the changes of BMD levels on a monthly basis. Also, results indicated an exponential behaviour of the BMD curve during the first year of life of the studied horses.

  20. Adaptive optics OCT using 1060nm swept source and dual deformable lenses for human retinal imaging

    NASA Astrophysics Data System (ADS)

    Jian, Yifan; Lee, Sujin; Cua, Michelle; Miao, Dongkai; Bonora, Stefano; Zawadzki, Robert J.; Sarunic, Marinko V.

    2016-03-01

    Adaptive optics concepts have been applied to the advancement of biological imaging and microscopy. In particular, AO has also been very successfully applied to cellular resolution imaging of the retina, enabling visualization of the characteristic mosaic patterns of the outer retinal layers using flood illumination fundus photography, Scanning Laser Ophthalmoscopy (SLO), and Optical Coherence Tomography (OCT). Despite the high quality of the in vivo images, there has been a limited uptake of AO imaging into the clinical environment. The high resolution afforded by AO comes at the price of limited field of view and specialized equipment. The implementation of a typical adaptive optics imaging system results in a relatively large and complex optical setup. The wavefront measurement is commonly performed using a Hartmann-Shack Wavefront Sensor (HS-WFS) placed at an image plane that is optically conjugated to the eye's pupil. The deformable mirror is also placed at a conjugate plane, relaying the wavefront corrections to the pupil. Due to the sensitivity of the HS-WFS to back-reflections, the imaging system is commonly constructed from spherical mirrors. In this project, we present a novel adaptive optics OCT retinal imaging system with significant potential to overcome many of the barriers to integration with a clinical environment. We describe in detail the implementation of a compact lens based wavefront sensorless adaptive optics (WSAO) 1060nm swept source OCT human retinal imaging system with dual deformable lenses, and present retinal images acquired in vivo from research volunteers.

  1. Noise-tolerance analysis for detection and reconstruction of absorbing inhomogeneities with diffuse optical tomography using single- and phase-correlated dual-source schemes

    NASA Astrophysics Data System (ADS)

    Kanmani, B.; Vasu, R. M.

    2007-03-01

    An iterative reconstruction procedure is used to invert intensity data from both single- and phase-correlated dual-source illuminations for absorption inhomogeneities. The Jacobian for the dual source is constructed by an algebraic addition of the Jacobians estimated for the two sources separately. By numerical simulations, it is shown that the dual-source scheme performs superior to the single-source system in regard to (i) noise tolerance in data and (ii) ability to reconstruct smaller and lower contrast objects. The quality of reconstructions from single-source data, as indicated by mean-square error at convergence, is markedly poorer compared to their dual-source counterpart, when noise in data was in excess of 2%. With fixed contrast and decreasing inhomogeneity diameter, our simulations showed that, for diameters below 7 mm, the dual-source scheme has a higher percentage contrast recovery compared to the single-source scheme. Similarly, the dual-source scheme reconstructs to a higher percentage contrast recovery from lower contrast inhomogeneity, in comparison to the single-source scheme.

  2. Virtual monochromatic imaging in dual-source and dual-energy CT for visualization of acute ischemic stroke

    NASA Astrophysics Data System (ADS)

    Hara, Hidetake; Muraishi, Hiroshi; Matsuzawa, Hiroki; Inoue, Toshiyuki; Nakajima, Yasuo; Satoh, Hitoshi; Abe, Shinji

    2015-07-01

    We have recently developed a phantom that simulates acute ischemic stroke. We attempted to visualize an acute-stage cerebral infarction by using dual-energy Computed tomography (DECT) to obtain virtual monochromatic images of this phantom. Virtual monochromatic images were created by using DECT voltages from 40 to 100 keV in steps of 10 keV and from 60 to 80 keV in steps of 1 keV, under three conditions of the tube voltage with thin (Sn) filters. Calculation of the CNR values allowed us to evaluate the visualization of acute-stage cerebral infarction. The CNR value of a virtual monochromatic image was the highest at 68 keV under 80 kV / Sn 140 kV, at 72 keV under 100 kV / Sn 140 kV, and at 67 keV under 140 kV / 80 kV. The CNR values of virtual monochromatic images at voltages between 65 and 75 keV were significantly higher than those obtained for all other created images. Therefore, the optimal conditions for visualizing acute ischemic stroke were achievable.

  3. Diagnosis of Pulmonary Artery Embolism: Comparison of Single-Source CT and 3rd Generation Dual-Source CT using a Dual-Energy Protocol Regarding Image Quality and Radiation Dose.

    PubMed

    Petritsch, Bernhard; Kosmala, Aleksander; Gassenmaier, Tobias; Weng, Andreas Max; Veldhoen, Simon; Kunz, Andreas Steven; Bley, Thorsten Alexander

    2017-06-01

    Purpose To compare radiation dose, subjective and objective image quality of 3 rd generation dual-source CT (DSCT) and dual-energy CT (DECT) with conventional 64-slice single-source CT (SSCT) for pulmonary CTA. Materials and Methods 180 pulmonary CTA studies were performed in three patient cohorts of 60 patients each. Group 1: conventional SSCT 120 kV (ref.); group 2: single-energy DSCT 100 kV (ref.); group 3: DECT 90/Sn150 kV. CTDIvol, DLP, effective radiation dose were reported, and CT attenuation (HU) was measured on three central and peripheral levels. The signal-to-noise-ratio (SNR) and contrast-to-noise-ratio (CNR) were calculated. Two readers assessed subjective image quality according to a five-point scale. Results Mean CTDIvol and DLP were significantly lower in the dual-energy group compared to the SSCT group (p < 0.001 [CTDIvol]; p < 0.001 [DLP]) and the DSCT group (p = 0.003 [CTDIvol]; p = 0.003 [DLP]), respectively. The effective dose in the DECT group was 2.79 ± 0.95 mSv and significantly smaller than in the SSCT group (4.60 ± 1.68 mSv, p < 0.001) and the DSCT group (4.24 ± 2.69 mSv, p = 0.003). The SNR and CNR were significantly higher in the DSCT group (p < 0.001). Subjective image quality did not differ significantly among the three protocols and was rated good to excellent in 75 % (135/180) of cases with an inter-observer agreement of 80 %. Conclusion Dual-energy pulmonary CTA protocols of 3 rd generation dual-source scanners allow for significant reduction of radiation dose while providing excellent image quality and potential additional information by means of perfusion maps. Key Points: · Dual-energy CT with 90/Sn150 kV configuration allows for significant dose reduction in pulmonary CTA.. · Subjective image quality was similar among the three evaluated CT-protocols (64-slice SSCT, single-energy DSCT, 90/Sn150 kV DECT) and was rated good to excellent in 75% of cases

  4. Feasibility Study of Computational Fluid Dynamics Simulation of Coronary Computed Tomography Angiography Based on Dual-Source Computed Tomography

    PubMed Central

    Lu, Jing; Yu, Jie; Shi, Heshui

    2017-01-01

    Background Adding functional features to morphological features offers a new method for non-invasive assessment of myocardial perfusion. This study aimed to explore technical routes of assessing the left coronary artery pressure gradient, wall shear stress distribution and blood flow velocity distribution, combining three-dimensional coronary model which was based on high resolution dual-source computed tomography (CT) with computational fluid dynamics (CFD) simulation. Methods Three cases of no obvious stenosis, mild stenosis and severe stenosis in left anterior descending (LAD) were enrolled. Images acquired on dual-source CT were input into software Mimics, ICEMCFD and FLUENT to simulate pressure gradient, wall shear stress distribution and blood flow velocity distribution. Measuring coronary enhancement ratio of coronary artery was to compare with pressure gradient. Results Results conformed to theoretical values and showed difference between normal and abnormal samples. Conclusions The study verified essential parameters and basic techniques in blood flow numerical simulation preliminarily. It was proved feasible. PMID:27924174

  5. Modulating effects of the low-frequency source on ion energy distributions in a dual frequency capacitively coupled plasma

    SciTech Connect

    Li Xiaosong; Bi Zhenhua; Chang Dalei; Li Zhicheng; Wang Shuai; Xu Xiang; Xu Yong; Lu Wenqi; Zhu Aimin; Wang Younian

    2008-07-21

    With the energy resolved quadrupole mass spectrometer and hybrid simulation, the influence of low-frequency (LF) source parameters on the ion energy distributions (IEDs) of argon ions impinging on the grounded electrode was studied, both experimentally and numerically, in a dual frequency capacitively coupled plasma. It was shown that for decreasing LF or increasing LF power, the high energy peak in IEDs shifts toward the high energy region significantly. The simulation results were in general agreement with the experimental data.

  6. Initial Experience of the Application of Automated Tube Potential Selection Technique in High-pitch Dual-source CT Angiography of Whole Aorta Using Third-generation Dual-source CT Scanner.

    PubMed

    Kong, Lingyan; Liang, Jixiang; Xue, Huadan; Wang, Yining; Wang, Yun; Jin, Zhengyu; Zhang, Daming; Chen, Jin

    2017-02-20

    Objective To evaluate the application of automated tube potential selection technique in high-pitch dual-source CT aortic angiography on a third-generation dual-source CT scanner. Methods Whole aorta angiography were indiated in 59 patients,who were divided into 2 groups using a simple random method:in group 1 there were 31 patients who underwent the examination with automated tube potential selection using a vascular setting with a preferred image quality of 288 mA/100 kV;in group 2 there were 28 patients who underwent the examination with a tube voltage of 100 kV and automated tube current modulation using a reference tube current of 288 mA. Both groups were scanned on a third generation dual-source CT device operated in dual-source high-pitch ECG-gating mode with a pitch of 3.0,collimation of 2×192×0.6 mm,and a rotation time of 0.25 s. Iterative reconstruction algorithm was used. For group 1,the volume and flow of contrast medium and chasing saline were adapted to the tube voltage. For group 2,a contrast material bolus of 45 ml with a flow of 4.5 ml/s followed by a 50 ml saline chaser at 5 ml/s was used. CTA scan was automatically started using a bolus tracking technique at the level of the original part of aorta after a trigger threshold of 100 HU was reached. The start delay was set to 6 s in both groups. Effective dose (ED),signal to noise ratio (SNR),contrast to noise ratio (CNR),and subjective diagnostic quality of both groups were evaluated. Results The mean ED were 21.3% lower (t=-3.099,P=0.000) in group 1 [(2.48±0.80) mSv] than in group 2 [(3.15±0.86) mSv]. Two groups showed no significant difference in attenuation,SD,SNR,or CNR at all evaluational parts of aorta (ascending aorta,aortic arch,diaphragmatic aorta,or iliac bifurcation)(all P>0.05). There was no significant difference in subjective diagnostic quality values of two groups [(1.41±0.50) scores vs. (1.39±0.50) scores;W=828.5,P=0.837]. Conclusion Compared with automated tube current

  7. Intensity distribution and impact of scatter for dual-source CT

    NASA Astrophysics Data System (ADS)

    Kyriakou, Yiannis; Kalender, Willi A.

    2007-12-01

    Apart from forward scatter, which is given for all CT scanners, dual-source CT (DSCT) is also affected by cross-scatter photons from the second tube-detector system arranged at 90°. We investigated the magnitude and distribution of scatter for DSCT and its impact on image quality. Simulations and measurements of homogeneous and anthropomorphic phantoms were conducted for a DSCT scanner (SOMATOM Definition, Siemens Medical Solutions, Forchheim, Germany) at tube voltages of 80 and 120 kV. The simulations of forward scatter were carried out using combined analytical and Monte Carlo simulation methods for a collimation of 19.2 mm for both tube-detector systems. Measurements of cross scatter were performed by switching one tube off, still reading out the corresponding detector. The relative scatter fractions and the distribution of cross scatter were registered for various imaging conditions. Additionally, a detailed noise analysis with respect to the correction of cross-scatter artifacts is provided to evaluate the performance of correction algorithms. The forward-scatter fraction increased with increasing phantom diameter from 0.02 up to 0.11 for PMMA phantoms of 80 to 400 mm diameter. For cross scatter, the mean intensity was equivalent to forward scatter for small phantoms but was larger for increased phantom size and resulted in severe artifacts in the reconstructed images. The outer dimensions and shape of the object are decisive for the cross-scatter intensity distribution whereas the influence of the degree of inhomogeneity of the respective phantom appears to be negligible. Scatter correction suppressed cross-scatter artifacts but increased noise as a function of the cross-scatter fraction. The magnitude of scatter is not negligible for DSCT systems and dedicated corrections are necessary for the assurance of unimpaired image quality.

  8. Dual-Source Computed Tomography for Chronic Total Occlusion of Coronary Arteries.

    PubMed

    Singh, Sandeep; Singh, Navreet; Gulati, Gurpreet S; Ramakrishnan, Sivasubramanian; Kumar, Guresh; Sharma, Sanjiv; Bahl, Vinay K

    2016-10-01

    We compared dual-source CT (DSCT) and conventional angiography (CA) in evaluation of chronic total occlusion (CTO) of coronary arteries. Percutaneous coronary intervention (PCI) in CTO is technically difficult and has comparatively lower success rate than intervention in non-occluded artery. Accurate assessment of lesion morphology is an important determinant of PCI success in CTO. Nineteen symptomatic patients (18 men, age: 58.6 ± 10.6 years) with a CTO on CA were subjected to a DSCT (Definition, Siemens, Germany). Heart rate (HR) control was not performed. Dedicated post-processing software was used for lesion analysis on both modalities. Presence of bridging collaterals, stump morphology, calcification, side branch, proximal tortuosity, occlusion length, distal vessel interpretability, and distal lesions were statistically compared. There were 20 CTOs. HR during DSCT ranged from 53 to 131 bpm. Bridging collaterals were seen in 3/20 (15%) lesions on CA and in none on DSCT. Stump anatomy and side branch were identified equally well. Plaque calcification was identified in 5/20 (25%) lesions on CA and in 12/20 (60%) lesions on DSCT (P = 0.025). Nature and extent of calcification were better visualized on DSCT. No proximal tortuosity was noted. Distal vessel was better interpretable on DSCT (15/20; 75%) compared to CA (9/20; 45%) (P = 0.05). No significant difference in lesion length was noted. DSCT performs as well as CA for most features of CTO. Avoidance of need to control HR, ability to better detect and characterize calcium and to interpret distal vessels make it a useful pre-intervention investigation. © 2014 Wiley Periodicals, Inc. © 2014 Wiley Periodicals, Inc.

  9. Dual-source computed tomography angiography image quality in patients with fast heart rates.

    PubMed

    Srichai, Monvadi B; Hecht, Elizabeth M; Kim, Danny; Babb, James; Bod, Jessica; Bodd, Jessica; Jacobs, Jill E

    2009-01-01

    Dual-source computed tomography (DSCT) provides diagnostic quality images of the coronary arteries over a wide range of heart rates (HRs). Current dose reduction techniques, including electrocardiographic (ECG) dose modulation and prospective triggering, are optimized for use in patients with relatively slow (<70 beats/min) HRs by limiting radiation dose to the ideal phases of image acquisition. We evaluated coronary vessel image quality (IQ) at different reconstruction phases in patients with fast HRs (>80 beats/min) to assess potential feasibility of prospective triggering techniques on DSCT. Patients (n=101) underwent 64-slice DSCT with retrospective ECG-gating without beta-blocker premedication. Image reconstructions were performed at 10% R-R wave phase intervals (0%-90%). Patients were grouped by mean HR: group A, <60 beats/min (n=22); group B, 60-80 beats/min (n=57); group C, >80 beats/min (n=22). Coronary artery IQ was assessed by 2 readers in consensus on a 5-point scale. Optimal IQ occurred at 70% phase for all arteries in groups A and B. In group C, optimal IQ occurred at 30% and 40% phases. The 70% phase achieved diagnostic IQ in 97% of group A and 86% of group B. A widened reconstruction window (30%-50%) was necessary for diagnostic IQ in a similar high proportion (84%) of group C. Optimal IQ occurs during late-systolic phases for patients with fast HRs (>80 beats/min). Late-systolic phase prospective triggering is potentially feasible in these patients; however, given the widened reconstruction windows required, a higher radiation dose may be required compared with patients with slower HRs (<80 beats/min).

  10. Adult congenital heart disease imaging with second-generation dual-source computed tomography: initial experiences and findings.

    PubMed

    Ghoshhajra, Brian B; Sidhu, Manavjot S; El-Sherief, Ahmed; Rojas, Carlos; Yeh, Doreen Defaria; Engel, Leif-Christopher; Liberthson, Richard; Abbara, Suhny; Bhatt, Ami

    2012-01-01

    Adult congenital heart disease patients present a unique challenge to the cardiac imager. Patients may present with both acute and chronic manifestations of their complex congenital heart disease and also require surveillance for sequelae of their medical and surgical interventions. Multimodality imaging is often required to clarify their anatomy and physiology. Radiation dose is of particular concern in these patients with lifelong imaging needs for their chronic disease. The second-generation dual-source scanner is a recently available advanced clinical cardiac computed tomography (CT) scanner. It offers a combination of the high-spatial resolution of modern CT, the high-temporal resolution of dual-source technology, and the wide z-axis coverage of modern cone-beam geometry CT scanners. These advances in technology allow novel protocols that markedly reduce scan time, significantly reduce radiation exposure, and expand the physiologic imaging capabilities of cardiac CT. We present a case series of complicated adult congenital heart disease patients imaged by the second-generation dual-source CT scanner with extremely low-radiation doses and excellent image quality. © 2012 Wiley Periodicals, Inc.

  11. Prospective prediction of the major component of urinary stone composition with dual-source dual-energy CT in vivo.

    PubMed

    Zhang, G-M-Y; Sun, H; Xue, H-D; Xiao, H; Zhang, X-B; Jin, Z-Y

    2016-11-01

    To prospectively evaluate the diagnostic accuracy of dual-source dual-energy computed tomography (DSDECT) for predicting the major component and determining the composition of urinary calculi in patients with urolithiasis, using postoperative in vitro Fourier transform infrared spectroscopy (FT-IR) analysis as the reference standard. Patients with known urolithiasis underwent preoperative DSDECT evaluation, and subsequently, underwent surgical removal of the stones. All patients were examined using the dual-energy renal stone protocol. Material-specific chromatic images were made using dedicated post-processing software. The final determination of stone composition was made using FT-IR postoperatively. Diagnostic parameters of DSDECT for predicting the major component and detecting the presence of four composition types were calculated. A total of 81 urinary calculi were included in this study. Forty-three were pure stones and 38 were mixed stones according to FT-IR. DSDECT correctly identified the major component of all pure stones and 36 mixed stones. The major component of two mixed stones with uric acid as the major component was falsely interpreted as calcium oxalate. The overall accuracy of DSDECT for predicting the major component of stones was 97.5% (79/81). The accuracy of DSDECT for detecting the presence of four types of composition, uric acid, cysteine, hydroxyapatite, and calcium oxalate, was 97.5% (79/81), 93.8% (76/81), 80.2% (65/81), and 93.8% (76/81), respectively. DSDECT could accurately predict the major component of urinary calculi and detect uric acid, cysteine, and calcium oxalate with a satisfactory accuracy. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  12. Europium-155 as a source for dual energy cone beam computed tomography in adaptive proton therapy: A simulation study.

    PubMed

    Zhu, Jiahua; Penfold, Scott N

    2017-07-04

    To investigate the feasibility of a 3D imaging system utilizing a (155) Eu source and pixelated cadmium-zinc-telluride (CZT) detector for applications in adaptive radiotherapy. Specifically, to compare the reconstructed stopping power ratio (SPR) values of a head phantom obtained with the proposed imaging technique with theoretical SPR values. A Geant4 Monte Carlo simulation was performed with the novel imaging system. The simulation was repeated with a typical 120 kV X-ray tube spectrum while maintaining all other parameters. Dual energy (155) Eu source cone beam computed tomography (CBCT) images were reconstructed with an iterative projection algorithm known as total variation superiorization with diagonally relaxed orthogonal projections (TVS-DROP). Single energy 120 kV source CBCT images were also reconstructed with TVS-DROP. Reconstructed images were converted to SPR with stoichiometric calibration techniques based on ICRU 44 tissues. Quantitative accuracy of reconstructed attenuation coefficient images as well as SPR images were compared. Images generated by gamma emissions of (155) Eu showed superior contrast resolution to those generated by the 120 kV spectrum. Quantitatively, all reconstructed images correlated with reference attenuation coefficients of the head phantom within 1 standard deviation. Images generated with the (155) Eu source showed a smaller standard deviation of pixel values. Use of a dual energy conversion into SPR resulted in superior SPR accuracy with the (155) Eu source. (155) Eu was found to display desirable qualities when used as a source for dual energy CBCT. Further work is required to demonstrate whether the simulation results presented here can be translated into an experimental prototype. © 2017 American Association of Physicists in Medicine.

  13. Silicon photonic integrated circuit swept-source optical coherence tomography receiver with dual polarization, dual balanced, in-phase and quadrature detection.

    PubMed

    Wang, Zhao; Lee, Hsiang-Chieh; Vermeulen, Diedrik; Chen, Long; Nielsen, Torben; Park, Seo Yeon; Ghaemi, Allan; Swanson, Eric; Doerr, Chris; Fujimoto, James

    2015-07-01

    Optical coherence tomography (OCT) is a widely used three-dimensional (3D) optical imaging method with many biomedical and non-medical applications. Miniaturization, cost reduction, and increased functionality of OCT systems will be critical for future emerging clinical applications. We present a silicon photonic integrated circuit swept-source OCT (SS-OCT) coherent receiver with dual polarization, dual balanced, in-phase and quadrature (IQ) detection. We demonstrate multiple functional capabilities of IQ polarization resolved detection including: complex-conjugate suppressed full-range OCT, polarization diversity detection, and polarization-sensitive OCT. To our knowledge, this is the first demonstration of a silicon photonic integrated receiver for OCT. The integrated coherent receiver provides a miniaturized, low-cost solution for SS-OCT, and is also a key step towards a fully integrated high speed SS-OCT system with good performance and multi-functional capabilities. With further performance improvement and cost reduction, photonic integrated technology promises to greatly increase penetration of OCT systems in existing applications and enable new applications.

  14. Silicon photonic integrated circuit swept-source optical coherence tomography receiver with dual polarization, dual balanced, in-phase and quadrature detection

    PubMed Central

    Wang, Zhao; Lee, Hsiang-Chieh; Vermeulen, Diedrik; Chen, Long; Nielsen, Torben; Park, Seo Yeon; Ghaemi, Allan; Swanson, Eric; Doerr, Chris; Fujimoto, James

    2015-01-01

    Optical coherence tomography (OCT) is a widely used three-dimensional (3D) optical imaging method with many biomedical and non-medical applications. Miniaturization, cost reduction, and increased functionality of OCT systems will be critical for future emerging clinical applications. We present a silicon photonic integrated circuit swept-source OCT (SS-OCT) coherent receiver with dual polarization, dual balanced, in-phase and quadrature (IQ) detection. We demonstrate multiple functional capabilities of IQ polarization resolved detection including: complex-conjugate suppressed full-range OCT, polarization diversity detection, and polarization-sensitive OCT. To our knowledge, this is the first demonstration of a silicon photonic integrated receiver for OCT. The integrated coherent receiver provides a miniaturized, low-cost solution for SS-OCT, and is also a key step towards a fully integrated high speed SS-OCT system with good performance and multi-functional capabilities. With further performance improvement and cost reduction, photonic integrated technology promises to greatly increase penetration of OCT systems in existing applications and enable new applications. PMID:26203382

  15. Applying high frame-rate digital radiography and dual-energy distributed-sources for advanced tomosynthesis

    NASA Astrophysics Data System (ADS)

    Travish, Gil; Rangel, Felix J.; Evans, Mark A.; Schmiedehausen, Kristin

    2013-09-01

    Conventional radiography uses a single point x-ray source with a fan or cone beam to visualize various areas of the human body. An imager records the transmitted photons—historically film and now increasingly digital radiography (DR) flat panel detectors—followed by optional image post-processing. Some post-processing techniques of particular interest are tomosynthesis, and dual energy subtraction. Tomosynthesis adds the ability to recreate quasi-3D images from a series of 2D projections. These exposures are typically taken along an arc or other path; and, tomosynthesis reconstruction is used to form a three-dimensional representation of the area of interest. Dual-energy radiography adds the ability to enhance or "eliminate" structures based on their different attenuation of well-separated end-point energies in two exposures. These advanced capabilities come at a high cost in terms of complexity, imaging time, capital equipment, space, and potentially reduced image quality due to motion blur if acquired sequentially. Recently, the prospect of creating x-ray sources, which are composed of arrays of micro-emitters, has been put forward. These arrays offer a flat-panel geometry and may afford advantages in fabrication methodology, size and cost. They also facilitate the use of the dual energy technology. Here we examine the possibility of using such an array of x-ray sources combined with high frame-rate (~kHz) DR detectors to produce advanced medical images without the need for moving gantries or other complex motion systems. Combining the advantages of dual energy imaging with the ability to determine the relative depth location of anatomical structures or pathological findings from imaging procedures should prove to be a powerful diagnostic tool. We also present use cases that would benefit from the capabilities of this modality.

  16. Radiation dose efficiency of dual-energy CT benchmarked against single-source, kilovoltage-optimized scans

    PubMed Central

    Pratap, Jit

    2016-01-01

    Objective: This study evaluated the radiation dose and image quality implications of dual-energy CT (DECT) use, compared with kilovoltage-optimized single-source/single-energy CT (SECT) on a dual-source Siemens Somatom® Definition Flash CT scanner (Siemens Healthcare, Forcheim, Germany). Methods: With equalized radiation dose (volumetric CT dose index), image noise (standard deviation of CT number) and signal-difference-to-noise ratio (SDNR) were measured and compared across three techniques: 100, 120 and 100/140 kVp (dual energy). Noise in a 30-cm-diameter water phantom and SDNR within unenhanced soft-tissue regions of a small adult (50 kg/165 cm) anthropomorphic phantom were utilized for the assessment. Results: Water phantom image noise decreased with DECT compared with the lower noise SECT setting of 120 kVp (p = 0.046). A decrease in SDNR within the anthropomorphic phantom was demonstrated at 120 kVp compared with the SECT kilovoltage-optimized setting of 100 kVp (p = 0.001). A further decrease in SDNR was observed for the DECT technique when compared with 120 kVp (p = 0.01). Conclusion: On the Siemens Somatom Definition Flash system (Siemens Healthcare), and for equalized radiation dose conditions, image quality expressed as SDNR of unenhanced soft tissue may be compromised for DECT when compared with kilovoltage-optimized SECT, particularly for smaller patients. Advances in knowledge: DECT on a dual-source CT scanner may require a radiation dose increase to maintain unenhanced soft-tissue contrast detectability, particularly for smaller patients. PMID:26559438

  17. Differentiation of small intrahepatic mass-forming cholangiocarcinoma from small liver abscess by dual source dual-energy CT quantitative parameters.

    PubMed

    Kim, Ji Eun; Kim, Hyun Ok; Bae, Kyungsoo; Cho, Jae Min; Choi, Ho Cheol; Choi, Dae Seob

    2017-07-01

    To investigate the use of dual source dual-energy CT (DECT) quantitative parameters compared with the use of conventional CT for differentiating small (≤3cm) intrahepatic mass-forming cholangiocarcinoma (IMCC) from small liver abscess (LA) during the portal venous phase (PVP). In this institutional review board-approved, retrospective study, 64 patients with IMCCs and 52 patients with LAs who were imaged in PVP using dual-energy mode were included retrospectively. A radiologist drew circular regions of interest in the lesion on the virtual monochromatic images (VMI), color-coded iodine overlay images, and linear blending images with a linear blending ratio of 0.3 to obtain CT value, its standard deviation, slope (k) of spectral curve and normalized iodine concentration (NIC). Two radiologists assessed lesion type on the basis of qualitative CT imaging features. CT values on VMI at 50-130keV (20keV-interval), k, and NIC values were significantly higher in IMCCs than in LAs (p<0.0001). The best single parameter for differentiating IMCC from LA was CT value at 90keV, with sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of 89.1%, 86.5%, 87.9%, 89.1%, and 86.5%, respectively. The best combination of parameters was CT value at 90keV, k, and NIC, with values of 87.5%, 84.6%, 83.6%, 87.5%, and 84.6%, respectively. Compared with CT value at linear blending images, CT value at 90keV showed greater sensitivity (89.1% vs 60.9%, p<0.0001) and similar specificity (86.5% vs 84.6%, p=1.0000), and combined CT value at 90keV, k, and NIC showed greater sensitivity (87.5% vs 60.9%, p<0.0001) and similar specificity (84.6% vs 84.6%, p=1.0000). Compared with qualitative analysis, CT value at 90keV showed greater sensitivity (89.1% vs 65.6%, p=0.0059) and specificity (86.5% vs 69.2%, p=0.0352), and combined CT value at 90keV, k, and NIC showed greater sensitivity (87.5% vs 65.6%, p=0.0094) and similar specificity (84.6% vs 69.2%, p >0

  18. Analysis of Pulmonary Vein Antrums Motion with Cardiac Contraction Using Dual-Source Computed Tomography

    PubMed Central

    de Guise, Jacques; Vu, Toni; Chartrand-Lefebvre, Carl; Blais, Danis; Lebeau, Martin; Nguyen, Nhu-Tram; Roberge, David

    2016-01-01

    Purpose: The purpose of the study was to determine the extent of displacement of the pulmonary vein antrums resulting from the intrinsic motion of the heart using 4D cardiac dual-source computed tomography (DSCT). Methods: Ten consecutive female patients were enrolled in this prospective planning study. In breath-hold, a contrast-injected cardiac 4-dimensional (4D) computed tomography (CT) synchronized to the electrocardiogram was obtained using a prospective sequential acquisition method including the extreme phases of systole and diastole. Right and left atrial fibrillation target volumes (CTVR and CTVL) were defined, with each target volume containing the antral regions of the superior and inferior pulmonary veins. Four points of interest were used as surrogates for the right superior and inferior pulmonary vein antrum (RSPVA and RIPVA) and the left superior and inferior pulmonary vein antrum (LSPVA and LIPVA). On our 4D post-processing workstation (MIM Maestro™, MIM Software Inc.), maximum displacement of each point of interest from diastole to systole was measured in the mediolateral (ML), anteroposterior (AP), and superoinferior (SI) directions. Results: Median age of the enrolled patients was 60 years (range, 56-71 years). Within the CTVR, the mean displacements of the superior and inferior surrogates were 3 mm vs. 1 mm (p=0.002), 2 mm vs. 0 mm (p= 0.001), and 3 mm vs. 0 mm (p=0.00001), in the ML, AP, and SI directions, respectively. On the left, mean absolute displacements of the LSPVA vs. LIPVA were similar at 4 mm vs. 1 mm (p=0.0008), 2 mm vs. 0 mm (p= 0.001), and 3 mm vs. 1 mm (p=0.00001) in the ML, AP, and SI directions. Conclusion: When isolated from breathing, cardiac contraction is associated with minimal inferior pulmonary veins motion and modest (1-6 mm) motion of the superior veins. Target deformation was thus of a magnitude similar or greater than target motion, limiting the potential gains of cardiac tracking. Optimal strategies for cardiac

  19. Image reconstruction and image quality evaluation for a dual source CT scanner.

    PubMed

    Flohr, T G; Bruder, H; Stierstorfer, K; Petersilka, M; Schmidt, B; McCollough, C H

    2008-12-01

    The authors present and evaluate concepts for image reconstruction in dual source CT (DSCT). They describe both standard spiral (helical) DSCT image reconstruction and electrocardiogram (ECG)-synchronized image reconstruction. For a compact mechanical design of the DSCT, one detector (A) can cover the full scan field of view, while the other detector (B) has to be restricted to a smaller, central field of view. The authors develop an algorithm for scan data completion, extrapolating truncated data of detector (B) by using data of detector (A). They propose a unified framework for convolution and simultaneous 3D backprojection of both (A) and (B) data, with similar treatment of standard spiral, ECG-gated spiral, and sequential (axial) scan data. In ECG-synchronized image reconstruction, a flexible scan data range per measurement system can be used to trade off temporal resolution for reduced image noise. Both data extrapolation and image reconstruction are evaluated by means of computer simulated data of anthropomorphic phantoms, by phantom measurements and patient studies. The authors show that a consistent filter direction along the spiral tangent on both detectors is essential to reduce cone-beam artifacts, requiring truncation of the extrapolated (B) data after convolution in standard spiral scans. Reconstructions of an anthropomorphic thorax phantom demonstrate good image quality and dose accumulation as theoretically expected for simultaneous 3D backprojection of the filtered (A) data and the truncated filtered (B) data into the same 3D image volume. In ECG-gated spiral modes, spiral slice sensitivity profiles (SSPs) show only minor dependence on the patient's heart rate if the spiral pitch is properly adapted. Measurements with a thin gold plate phantom result in effective slice widths (full width at half maximum of the SSP) of 0.63-0.69 mm for the nominal 0.6 mm slice and 0.82-0.87 mm for the nominal 0.75 mm slice. The visually determined through-plane (z

  20. Robust image transmission using a new joint source channel coding algorithm and dual adaptive OFDM

    NASA Astrophysics Data System (ADS)

    Farshchian, Masoud; Cho, Sungdae; Pearlman, William A.

    2004-01-01

    In this paper we consider the problem of robust image coding and packetization for the purpose of communications over slow fading frequency selective channels and channels with a shaped spectrum like those of digital subscribe lines (DSL). Towards this end, a novel and analytically based joint source channel coding (JSCC) algorithm to assign unequal error protection is presented. Under a block budget constraint, the image bitstream is de-multiplexed into two classes with different error responses. The algorithm assigns unequal error protection (UEP) in a way to minimize the expected mean square error (MSE) at the receiver while minimizing the probability of catastrophic failure. In order to minimize the expected mean square error at the receiver, the algorithm assigns unequal protection to the value bit class (VBC) stream. In order to minimizes the probability of catastrophic error which is a characteristic of progressive image coders, the algorithm assigns more protection to the location bit class (LBC) stream than the VBC stream. Besides having the advantage of being analytical and also numerically solvable, the algorithm is based on a new formula developed to estimate the distortion rate (D-R) curve for the VBC portion of SPIHT. The major advantage of our technique is that the worst case instantaneous minimum peak signal to noise ratio (PSNR) does not differ greatly from the averge MSE while this is not the case for the optimal single stream (UEP) system. Although both average PSNR of our method and the optimal single stream UEP are about the same, our scheme does not suffer erratic behavior because we have made the probability of catastrophic error arbitarily small. The coded image is sent via orthogonal frequency division multiplexing (OFDM) which is a known and increasing popular modulation scheme to combat ISI (Inter Symbol Interference) and impulsive noise. Using dual adaptive energy OFDM, we use the minimum energy necessary to send each bit stream at a

  1. Coronary CT angiography in the emergency department utilizing second and third generation dual source CT.

    PubMed

    Meyersohn, Nandini M; Szilveszter, Balint; Staziaki, Pedro V; Scholtz, Jan-Erik; Takx, Richard A P; Hoffmann, Udo; Ghoshhajra, Brian B

    Coronary computed tomography angiography (coronary CTA) allows efficient triage of low to intermediate risk patients with suspected acute coronary syndrome (ACS) in the emergency department (ED). Techniques for coronary CTA acquisition in the ED continue to evolve with the establishment of standardized scan protocols and the introduction of newer generations of CT hardware. To evaluate qualitative and quantitative image quality and radiation dose exposure of coronary CTA acquired on 2nd versus 3rd generation dual source CT (DSCT) scanners using a standardized institutional scan protocol designed for the ED. A retrospective observational case-control study was performed of 246 ED patients referred to coronary CTA with suspicion of ACS (56.5% male; mean age 53.3 ± 11.6 years) between October 2013 and August 2015.123 consecutive patients were scanned on 3rd generation DSCT, and a cohort of 123 patients matched by age, BMI and heart rate were identified who had undergone 2nd generation DSCT imaging utilizing the same standard clinical protocol. Qualitative and quantitative image quality parameters and radiation exposures were evaluated. Qualitative image quality was significantly higher using 3rd generation DSCT as compared to 2nd generation (p < 0.001). Mean attenuation in the proximal coronary arteries was also significantly higher on 3rd generation DSCT than for 2nd generation (586 HU vs. 426 HU in the left main coronary artery (LM), p < 0.001). Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) values, however, were lower in 3rd generation DSCT than 2nd generation (SNR 11.2 [9.9-13.4] vs 13.5 [11.0-15.5] and CNR 12.4 [10.9-14.8] vs 15.2 [12.8-17.9] in the LM, p < 0.001). Median effective dose was also lower for 3rd generation DSCT than for 2nd generation (2.9 [2.3-5.0] mSv and 3.7 mSv [2.5-5.7], respectively) although this trend did not reach statistical significance (p = 0.065). Qualitative image quality and mean CT attenuation values of the

  2. Contrast media volume optimization in high-pitch dual-source CT coronary angiography: feasibility study.

    PubMed

    Yang, Wen Jie; Chen, Ke Min; Liu, Bo; Pang, Li Fang; Zhang, Huan; Pan, Zi Lai; Yan, Fu Hua

    2013-01-01

    To investigate the feasibility of contrast media (CM) volume reduction in dual-source coronary computed tomography angiography high-pitch mode without affecting coronary artery enhancement. Eighty patients were involved in a preliminary experiment with a default injection protocol (60 ml of CM). The age, BMI, test bolus (TB) enhancement peak and the CT values of coronary artery for each patient were recorded and the key factors for determining coronary artery enhancement were investigated. Based on the results of the preliminary experiment, 120 patients were involved in the main experiment with a new injection protocol. For each patient, the CT values and noise of left coronary sinus (LCS), and the distal segment of right coronary artery were measured. In the preliminary experiment, the peak enhancement of TB correlated most strongly with the HU values of coronary artery. Consequently, the new injection protocol was devised to catalog patients into four groups (30, 40, 50 and 60 ml) of CM based on their TB peak enhancement. In the main experiment, the 30 ml CM injection group whose peak attenuation of TB were the highest (30 vs. 40,50,60 ml: 323.0 ± 27.5 vs. 264.2 ± 11.9, 242.1 ± 8.8, 206.2 ± 18.2 HU, p < 0.05), obtained the highest attenuation of LCS (30 vs. 40,50,60 ml: 365.0 ± 41.2 vs. 341.8 ± 40.0, 326.9 ± 34.7, 312.5 ± 38.2 HU p < 0.05). Contrast optimization is feasible in high-pitch DSCT coronary angiography. Certain patients may receive 30 ml of CM without affecting vessel enhancement.

  3. Impact on Image Quality and Radiation Dose of Third-Generation Dual-Source Computed Tomography of the Coronary Arteries.

    PubMed

    Apfaltrer, Georg; Szolar, Dieter H; Wurzinger, Eric; Takx, Richard A P; Nance, John W; Dutschke, Anja; Tschauner, Sebastian; Loewe, Christian; Ringl, Helmut; Sorantin, Erich; Apfaltrer, Paul

    2017-04-15

    The aim of this study was to assess the image quality (IQ) and radiation dose of third-generation dual-source computed tomography (CT) coronary angiography (cCTA) in comparison with 64-slice single-source CT. This retrospective study included 140 patients (73 men, mean age 62 ± 11 years) with low-to-intermediate probability of coronary artery disease who underwent either third-generation dual-source cCTA using prospectively electrocardiography-triggered high-pitch spiral acquisition (n = 70) (group 1) or retrospective electrocardiography-gated cCTA on a 64-slice CT system (n = 70) (group 2). Contrast-to-noise and signal-to-noise ratios were measured within the aorta and coronary arteries. Subjective IQ was assessed using a 5-point Likert scale. Effective dose was estimated using specific conversion factors. The contrast-to-noise ratio of group 1 was significantly higher than group 2 at all levels (all p <0.001). Signal-to-noise ratio of group 1 was also significantly higher than group 2 (p <0.05), except for the distal left circumflex artery. Subjective IQ for group 1 was rated significantly better than for group 2 (median score [25th to 75th percentile]: 1 [1 to 2] vs 2 [2 to 3]; p <0.001). The median effective dose was 1.55 mSv (1.09 to 1.88) in group 1 versus 12.29 mSv (11.63 to 14.36) in group 2 (p <0.001) which corresponds to a mean radiation dose reduction of 87.4%. In conclusion, implementation of third-generation dual-source CT system for cCTA leads to improved IQ with significant radiation dose savings.

  4. The Source of Execution-Related Dual-Task Interference: Motor Bottleneck or Response Monitoring?

    ERIC Educational Resources Information Center

    Bratzke, Daniel; Rolke, Bettina; Ulrich, Rolf

    2009-01-01

    The present study assessed the underlying mechanism of execution-related dual-task interference in the psychological refractory period (PRP) paradigm. The motor bottleneck hypothesis attributes this interference to a processing limitation at the motor level. By contrast, the response monitoring hypothesis attributes it to a bottleneck process that…

  5. The Source of Execution-Related Dual-Task Interference: Motor Bottleneck or Response Monitoring?

    ERIC Educational Resources Information Center

    Bratzke, Daniel; Rolke, Bettina; Ulrich, Rolf

    2009-01-01

    The present study assessed the underlying mechanism of execution-related dual-task interference in the psychological refractory period (PRP) paradigm. The motor bottleneck hypothesis attributes this interference to a processing limitation at the motor level. By contrast, the response monitoring hypothesis attributes it to a bottleneck process that…

  6. Comprehensive Comparison of Virtual Monoenergetic and Linearly Blended Reconstruction Techniques in Third-Generation Dual-Source Dual-Energy Computed Tomography Angiography of the Thorax and Abdomen.

    PubMed

    Albrecht, Moritz H; Trommer, Jesko; Wichmann, Julian L; Scholtz, Jan-Erik; Martin, Simon S; Lehnert, Thomas; Vogl, Thomas J; Bodelle, Boris

    2016-09-01

    The aim of this study was to perform an objective and subjective image analysis of traditional and advanced noise-optimized virtual monoenergetic imaging (VMI) algorithms and standard linearly blended images in third-generation dual-source dual-energy computed tomography angiography (DE-CTA) of the thorax and abdomen. Thoracoabdominal DE-CTA examinations of 55 patients (36 male; mean age, 64.2 ± 12.7 years) were included in this retrospective institutional review board-approved study. Dual-energy computed tomography angiography data were reconstructed using standard linearly blended M_0.6 (merging 60% low kiloelectron volt [90 kV] with 40% high kiloelectron volt [150 kV] spectrum), traditional (VMI), and advanced VMI (VMI+) algorithms. Monoenergetic series were calculated ranging from 40 to 120 keV with 10 keV increments. Attenuation and standard deviation of 8 arteries and various anatomical landmarks of the thorax and abdomen were measured to calculate contrast-to-noise ratio values. Two radiologists subjectively assessed image quality, contrast conditions, noise, and visualization of small arterial branches using 5-point Likert scales. Vascular attenuation of VMI and VMI+ series showed a gradual increase from high to low kiloelectron volt levels without significant differences between both algorithms (P < 0.894). VMI+ 40-keV series showed the highest contrast-to-noise ratio for both thoracic and abdominal DE-CTA (P < 0.001), albeit revealing higher noise than M_0.6 images (objectively and subjectively, P < 0.001) and were rated best for visualization of small arterial branches in the subjective analysis (P < 0.109). Substantially increased noise was found for VMI 40 and 50 keV series compared with all other reconstructions (objectively and subjectively, P < 0.001). VMI+ images at 100 keV+ were rated best regarding image noise (P < 0.843), whereas VMI+ reconstructions at 70 keV were found to have superior subjective image quality (P < 0.031) compared with other

  7. Computed Tomography of the Head and Neck Region for Tumor Staging-Comparison of Dual-Source, Dual-Energy and Low-Kilovolt, Single-Energy Acquisitions.

    PubMed

    May, Matthias Stefan; Bruegel, Joscha; Brand, Michael; Wiesmueller, Marco; Krauss, Bernhard; Allmendinger, Thomas; Uder, Michael; Wuest, Wolfgang

    2017-09-01

    The aim of this study was to intra-individually compare the image quality obtained by dual-source, dual-energy (DSDE) computed tomography (CT) examinations and different virtual monoenergetic reconstructions to a low single-energy (SE) scan. Third-generation DSDE-CT was performed in 49 patients with histologically proven malignant disease of the head and neck region. Weighted average images (WAIs) and virtual monoenergetic images (VMIs) for low (40 and 60 keV) and high (120 and 190 keV) energies were reconstructed. A second scan aligned to the jaw, covering the oral cavity, was performed for every patient to reduce artifacts caused by dental hardware using a SE-CT protocol with 70-kV tube voltages and matching radiation dose settings. Objective image quality was evaluated by calculating contrast-to-noise ratios. Subjective image quality was evaluated by experienced radiologists. Highest contrast-to-noise ratios for vessel and tumor attenuation were obtained in 40-keV VMI (all P < 0.05). Comparable objective results were found in 60-keV VMI, WAI, and the 70-kV SE examinations. Overall subjective image quality was also highest for 40-keV, but differences to 60-keV VMI, WAI, and 70-kV SE were nonsignificant (all P > 0.05). High kiloelectron volt VMIs reduce metal artifacts with only limited diagnostic impact because of insufficiency in case of severe dental hardware. CTDIvol did not differ significantly between both examination protocols (DSDE: 18.6 mGy; 70-kV SE: 19.4 mGy; P = 0.10). High overall image quality for tumor delineation in head and neck imaging were obtained with 40-keV VMI. However, 70-kV SE examinations are an alternative and modified projections aligned to the jaw are recommended in case of severe artifacts caused by dental hardware.

  8. Dual-source dual-energy CT with additional tin filtration: Dose and image quality evaluation in phantoms and in-vivo

    PubMed Central

    Primak, Andrew N.; Giraldo, Juan Carlos Ramirez; Eusemann, Christian D.; Schmidt, Bernhard; Kantor, B.; Fletcher, Joel G.; McCollough, Cynthia H.

    2010-01-01

    Purpose To investigate the effect on radiation dose and image quality of the use of additional spectral filtration for dual-energy CT (DECT) imaging using dual-source CT (DSCT). Materials and Methods A commercial DSCT scanner was modified by adding tin filtration to the high-kV tube, and radiation output and noise measured in water phantoms. Dose values for equivalent image noise were compared among DE-modes with and without tin filtration and single-energy (SE) mode. To evaluate DECT material discrimination, the material-specific DEratio for calcium and iodine were determined using images of anthropomorphic phantoms. Data were additionally acquired in 38 and 87 kg pigs, and noise for the linearly mixed and virtual non-contrast (VNC) images compared between DE-modes. Finally, abdominal DECT images from two patients of similar sizes undergoing clinically-indicated CT were compared. Results Adding tin filtration to the high-kV tube improved the DE contrast between iodine and calcium as much as 290%. Pig data showed that the tin filtration had no effect on noise in the DECT mixed images, but decreased noise by as much as 30% in the VNC images. Patient VNC-images acquired using 100/140 kV with added tin filtration had improved image quality compared to those generated with 80/140 kV without tin filtration. Conclusion Tin filtration of the high-kV tube of a DSCT scanner increases the ability of DECT to discriminate between calcium and iodine, without increasing dose relative to SECT. Furthermore, use of 100/140 kV tube potentials allows improved DECT imaging of large patients. PMID:20966323

  9. Modeling of Single Event Transients With Dual Double-Exponential Current Sources: Implications for Logic Cell Characterization

    NASA Astrophysics Data System (ADS)

    Black, Dolores A.; Robinson, William H.; Wilcox, Ian Z.; Limbrick, Daniel B.; Black, Jeffrey D.

    2015-08-01

    Single event effects (SEE) are a reliability concern for modern microelectronics. Bit corruptions can be caused by single event upsets (SEUs) in the storage cells or by sampling single event transients (SETs) from a logic path. An accurate prediction of soft error susceptibility from SETs requires good models to convert collected charge into compact descriptions of the current injection process. This paper describes a simple, yet effective, method to model the current waveform resulting from a charge collection event for SET circuit simulations. The model uses two double-exponential current sources in parallel, and the results illustrate why a conventional model based on one double-exponential source can be incomplete. A small set of logic cells with varying input conditions, drive strength, and output loading are simulated to extract the parameters for the dual double-exponential current sources. The parameters are based upon both the node capacitance and the restoring current (i.e., drive strength) of the logic cell.

  10. Dual-source computed tomographic coronary angiography: image quality and stenosis diagnosis in patients with high heart rates.

    PubMed

    Zheng, Minwen; Li, Jiayi; Xu, Jian; Chen, Kang; Zhao, Hongliang; Huan, Yi

    2009-01-01

    We sought to evaluate prospectively the effects of heart rate and heart-rate variability on dual-source computed tomographic coronary image quality in patients whose heart rates were high, and to determine retrospectively the accuracy of dual-source computed tomographic diagnosis of coronary artery stenosis in the same patients.We compared image quality and diagnostic accuracy in 40 patients whose heart rates exceeded 70 beats/min with the same data in 40 patients whose heart rates were 70 beats/min or slower. In both groups, we analyzed 1,133 coronary arterial segments. Five hundred forty-five segments (97.7%) in low-heart-rate patients and 539 segments (93.7%) in high-heart-rate patients were of diagnostic image quality. We considered P < 0.05 to be statistically significant. No statistically significant differences between the groups were found in diagnostic-image quality scores of total segments or of any coronary artery, nor were any significant differences found between the groups in the accurate diagnosis of angiographically significant stenosis.Calcification was the chief factor that affected diagnostic accuracy. In high-heart-rate patients, heart-rate variability was significantly related to the diagnostic image quality of all segments (P = 0.001) and of the left circumflex coronary artery (P = 0.016). Heart-rate variability of more than 5 beats/min most strongly contributed to an inability to evaluate segments in both groups. When heart rates rose, the optimal reconstruction window shifted from diastole to systole.The image quality of dual-source computed tomographic coronary angiography at high heart rates enables sufficient diagnosis of stenosis, although variability of heart rates significantly deteriorates image quality.

  11. Low tube voltage dual source computed tomography to reduce contrast media doses in adult abdomen examinations: A phantom study.

    PubMed

    Thor, Daniel; Brismar, Torkel B; Fischer, Michael A

    2015-09-01

    To evaluate the potential of low tube voltage dual source (DS) single energy (SE) and dual energy (DE) computed tomography (CT) to reduce contrast media (CM) dose in adult abdominal examinations of various sizes while maintaining soft tissue and iodine contrast-to-noise ratio (CNR). Four abdominal phantoms simulating a body mass index of 16 to 35 kg/m(2) with four inserted syringes of 0, 2, 4, and 8 mgI/ml CM were scanned using a 64-slice DS-CT scanner. Six imaging protocols were used; one single source (SS) reference protocol (120 kV, 180 reference mAs), four low kV SE protocols (70 and 80 kV using both SS and DS), and one DE protocol at 80/140 kV. Potential CM reduction with unchanged CNRs relative to the 120 kV protocol was calculated along with the corresponding increase in radiation dose. The potential contrast media reductions were determined to be approximately 53% for DS 70 kV, 51% for SS 70 kV, 44% for DS 80 kV, 40% for SS 80 kV, and 20% for DE (all differences were significant, P < 0.05). Constant CNR could be achieved by using DS 70 kV for small to medium phantom sizes (16-26 kg/m(2)) and for all sizes (16-35 kg/m(2)) when using DS 80 kV and DE. Corresponding radiation doses increased by 60%-107%, 23%-83%, and 6%-12%, respectively. DS single energy CT can be used to reduce CM dose by 44%-53% with maintained CNR in adult abdominal examinations at the cost of an increased radiation dose. DS dual-energy CT allows reduction of CM dose by 20% at similar radiation dose as compared to a standard 120 kV single source.

  12. Performance of turbo high-pitch dual-source CT for coronary CT angiography: first ex vivo and patient experience.

    PubMed

    Morsbach, Fabian; Gordic, Sonja; Desbiolles, Lotus; Husarik, Daniela; Frauenfelder, Thomas; Schmidt, Bernhard; Allmendinger, Thomas; Wildermuth, Simon; Alkadhi, Hatem; Leschka, Sebastian

    2014-08-01

    To evaluate image quality, maximal heart rate allowing for diagnostic imaging, and radiation dose of turbo high-pitch dual-source coronary computed tomographic angiography (CCTA). First, a cardiac motion phantom simulating heart rates (HRs) from 60-90 bpm in 5-bpm steps was examined on a third-generation dual-source 192-slice CT (prospective ECG-triggering, pitch 3.2; rotation time, 250 ms). Subjective image quality regarding the presence of motion artefacts was interpreted by two readers on a four-point scale (1, excellent; 4, non-diagnostic). Objective image quality was assessed by calculating distortion vectors. Thereafter, 20 consecutive patients (median, 50 years) undergoing clinically indicated CCTA were included. In the phantom study, image quality was rated diagnostic up to the HR75 bpm, with object distortion being 1 mm or less. Distortion increased above 1 mm at HR of 80-90 bpm. Patients had a mean HR of 66 bpm (47-78 bpm). Coronary segments were of diagnostic image quality for all patients with HR up to 73 bpm. Average effective radiation dose in patients was 0.6 ± 0.3 mSv. Our combined phantom and patient study indicates that CCTA with turbo high-pitch third-generation dual-source 192-slice CT can be performed at HR up to 75 bpm while maintaining diagnostic image quality, being associated with an average radiation dose of 0.6 mSv. • CCTA is feasible with the turbo high-pitch mode. • Turbo high-pitch CCTA provides diagnostic image quality up to 73 bpm. • The radiation dose of high-pitch CCTA is 0.6 mSv on average.

  13. Single-source dual-energy computed tomography: use of monoenergetic extrapolation for a reduction of metal artifacts.

    PubMed

    Mangold, Stefanie; Gatidis, Sergios; Luz, Oliver; König, Benjamin; Schabel, Christoph; Bongers, Malte N; Flohr, Thomas G; Claussen, Claus D; Thomas, Christoph

    2014-12-01

    The objective of this study was to retrospectively determine the potential of virtual monoenergetic (ME) reconstructions for a reduction of metal artifacts using a new-generation single-source computed tomographic (CT) scanner. The ethics committee of our institution approved this retrospective study with a waiver of the need for informed consent. A total of 50 consecutive patients (29 men and 21 women; mean [SD] age, 51.3 [16.7] years) with metal implants after osteosynthetic fracture treatment who had been examined using a single-source CT scanner (SOMATOM Definition Edge; Siemens Healthcare, Forchheim, Germany; consecutive dual-energy mode with 140 kV/80 kV) were selected. Using commercially available postprocessing software (syngo Dual Energy; Siemens AG), virtual ME data sets with extrapolated energy of 130 keV were generated (medium smooth convolution kernel D30) and compared with standard polyenergetic images reconstructed with a B30 (medium smooth) and a B70 (sharp) kernel. For quantification of the beam hardening artifacts, CT values were measured on circular lines surrounding bone and the osteosynthetic device, and frequency analyses of these values were performed using discrete Fourier transform. A high proportion of low frequencies to the spectrum indicates a high level of metal artifacts. The measurements in all data sets were compared using the Wilcoxon signed rank test. The virtual ME images with extrapolated energy of 130 keV showed significantly lower contribution of low frequencies after the Fourier transform compared with any polyenergetic data set reconstructed with D30, B70, and B30 kernels (P < 0.001). Sequential single-source dual-energy CT allows an efficient reduction of metal artifacts using high-energy ME extrapolation after osteosynthetic fracture treatment.

  14. Plug-and-play Integration of dual-model based Knowledge Artefacts into an Open Source Ehr System.

    PubMed

    Krexner, Rabea; Duftschmid, Georg

    2014-01-01

    In this paper we present our experiences with extending an existing approach for an archetype-compliant collection and export of data according to the openEHR specifications within the open source EHR system OpenMRS. It allows an automatic generation of forms from templates, which were introduced by openEHR as an extension of the dual-model approach. Data entered in these forms can be exported in form of standardized EHR extracts. The use of templates allowed us to solve problems reported for the original archetype-based version of the approach, which were caused by the high optionality within archetypes.

  15. Heat Source/Sink in a Magneto-Hydrodynamic Non-Newtonian Fluid Flow in a Porous Medium: Dual Solutions

    PubMed Central

    Hayat, Tasawar; Awais, Muhammad; Imtiaz, Amna

    2016-01-01

    This communication deals with the properties of heat source/sink in a magneto-hydrodynamic flow of a non-Newtonian fluid immersed in a porous medium. Shrinking phenomenon along with the permeability of the wall is considered. Mathematical modelling is performed to convert the considered physical process into set of coupled nonlinear mathematical equations. Suitable transformations are invoked to convert the set of partial differential equations into nonlinear ordinary differential equations which are tackled numerically for the solution computations. It is noted that dual solutions for various physical parameters exist which are analyzed in detail. PMID:27598314

  16. Heat Source/Sink in a Magneto-Hydrodynamic Non-Newtonian Fluid Flow in a Porous Medium: Dual Solutions.

    PubMed

    Hayat, Tasawar; Awais, Muhammad; Imtiaz, Amna

    2016-01-01

    This communication deals with the properties of heat source/sink in a magneto-hydrodynamic flow of a non-Newtonian fluid immersed in a porous medium. Shrinking phenomenon along with the permeability of the wall is considered. Mathematical modelling is performed to convert the considered physical process into set of coupled nonlinear mathematical equations. Suitable transformations are invoked to convert the set of partial differential equations into nonlinear ordinary differential equations which are tackled numerically for the solution computations. It is noted that dual solutions for various physical parameters exist which are analyzed in detail.

  17. Single-source chest-abdomen-pelvis cancer staging on a third generation dual-source CT system: comparison of automated tube potential selection to second generation dual-source CT.

    PubMed

    Park, Clara; Gruber-Rouh, Tatjana; Leithner, Doris; Zierden, Amelie; Albrecht, Mortiz H; Wichmann, Julian L; Bodelle, Boris; Elsabaie, Mohamed; Scholtz, Jan-Erik; Kaup, Moritz; Vogl, Thomas J; Beeres, Martin

    2016-10-10

    Evaluation of latest generation automated attenuation-based tube potential selection (ATPS) impact on image quality and radiation dose in contrast-enhanced chest-abdomen-pelvis computed tomography examinations for gynaecologic cancer staging. This IRB approved single-centre, observer-blinded retrospective study with a waiver for informed consent included a total of 100 patients with contrast-enhanced chest-abdomen-pelvis CT for gynaecologic cancer staging. All patients were examined with activated ATPS for adaption of tube voltage to body habitus. 50 patients were scanned on a third-generation dual-source CT (DSCT), and another 50 patients on a second-generation DSCT. Predefined image quality setting remained stable between both groups at 120 kV and a current of 210 Reference mAs. Subjective image quality assessment was performed by two blinded readers independently. Attenuation and image noise were measured in several anatomic structures. Signal-to-noise ratio (SNR) was calculated. For the evaluation of radiation exposure, CT dose index (CTDIvol) values were compared. Diagnostic image quality was obtained in all patients. The median CTDIvol (6.1 mGy, range 3.9-22 mGy) was 40 % lower when using the algorithm compared with the previous ATCM protocol (median 10.2 mGy · cm, range 5.8-22.8 mGy). A reduction in potential to 90 kV occurred in 19 cases, a reduction to 100 kV in 23 patients and a reduction to 110 kV in 3 patients of our experimental cohort. These patients received significantly lower radiation exposure compared to the former used protocol. Latest generation automated ATPS on third-generation DSCT provides good diagnostic image quality in chest-abdomen-pelvis CT while average radiation dose is reduced by 40 % compared to former ATPS protocol on second-generation DSCT.

  18. Feasibility of Pediatric Chest CT Using Spectral Filtration on Third-generation Dual-source CT.

    PubMed

    Liu, Wei; Liu, Jingjuan; Xue, Huadan; Sui, Xin; Song, Wei; Xu, Kai; Wan, Weilin; Li, Zhenghong; Jin, Zhengyu

    2017-02-20

    Objective To prospectively investigate the radiation dose and image quality of pediatric chest CT using Sn100 kV on a third-generation dual-source CT (DSCT)in comparison to standard 100 kV chest CT. Methods From December 12,2015 to June 30,2016,45 consecutive pediatric patients referred for non-contrast chest CT scan in Peking Union Medical College Hospital were prospectively enrolled as study group. They were examined at 100 kV with a dedicated tin filter on a third-generation DSCT. These patients were retrospectively matched with 45 patients who were examined on a second-generation DSCT at 100 kV without tin filter. The radiation dose as well as the lung and mediastinal window image quality(IQ)of the two groups were compared and analyzed statistically. IQ was evaluated using a five-point scale (1=unevaluable,5=excellent). Differences of radiation dose and noise between the two groups were determined with variance analysis and t test,IQ with Mann-Whitney U test,and the consistency of diagnosis with Kappa test. Results The average CT dose index volume of the study group was (0.24±0.11)mGy,which was decreased by 92% compared with the control group [(3.10+1.18)mGy] (t=16.287,P=0.000). Mean dose-length product and mean effective dose for study group were significantly lower than those of control group [(7.13±4.72)mGy·cm vs. (84.78±46.78)mGy·cm,t=11.077,P=0.000;(0.11±0.06)mSv vs.(1.23±0.61)mSv,t=12.334,P=0.000]. There was no significant difference between the two groups in terms of image noise (t=-0.003,P=0.397)and contrast to noise ratio (t=0.545,P=0.488). There was no significant difference between the two groups in lung window IQ (doctor 1:U=796.000,P=0.055;doctor 2:U=889.500,P=0.277),while significant difference was seen concerning of the mediastinal window IQ (doctor 1:U=305.000,P=0.000;doctor 2:U=276.500,P=0.000). Referring to the lung window,the median IQ for the study group and control group was 4 (3-5)and 4 (3-5),respectively. All imaging findings had

  19. Image reconstruction and image quality evaluation for a dual source CT scanner

    PubMed Central

    Flohr, T. G.; Bruder, H.; Stierstorfer, K.; Petersilka, M.; Schmidt, B.; McCollough, C. H.

    2008-01-01

    The authors present and evaluate concepts for image reconstruction in dual source CT (DSCT). They describe both standard spiral (helical) DSCT image reconstruction and electrocardiogram (ECG)-synchronized image reconstruction. For a compact mechanical design of the DSCT, one detector (A) can cover the full scan field of view, while the other detector (B) has to be restricted to a smaller, central field of view. The authors develop an algorithm for scan data completion, extrapolating truncated data of detector (B) by using data of detector (A). They propose a unified framework for convolution and simultaneous 3D backprojection of both (A) and (B) data, with similar treatment of standard spiral, ECG-gated spiral, and sequential (axial) scan data. In ECG-synchronized image reconstruction, a flexible scan data range per measurement system can be used to trade off temporal resolution for reduced image noise. Both data extrapolation and image reconstruction are evaluated by means of computer simulated data of anthropomorphic phantoms, by phantom measurements and patient studies. The authors show that a consistent filter direction along the spiral tangent on both detectors is essential to reduce cone-beam artifacts, requiring truncation of the extrapolated (B) data after convolution in standard spiral scans. Reconstructions of an anthropomorphic thorax phantom demonstrate good image quality and dose accumulation as theoretically expected for simultaneous 3D backprojection of the filtered (A) data and the truncated filtered (B) data into the same 3D image volume. In ECG-gated spiral modes, spiral slice sensitivity profiles (SSPs) show only minor dependence on the patient’s heart rate if the spiral pitch is properly adapted. Measurements with a thin gold plate phantom result in effective slice widths (full width at half maximum of the SSP) of 0.63–0.69mm for the nominal 0.6mm slice and 0.82–0.87mm for the nominal 0.75mm slice. The visually determined through-plane (z

  20. A diode-pumped Nd:YAlO3 dual-wavelength yellow light source

    NASA Astrophysics Data System (ADS)

    Zhang, Jing; Fu, Xihong; Zhai, Pei; Xia, Jing; Li, Shutao

    2013-11-01

    We present what is, to the best of our knowledge, the first diode-pumped Nd:YAlO3 (Nd:YAP) continuous-wave (cw) dual-wavelength yellow laser at 593 nm and 598 nm, based on sum-frequency generation between 1064 and 1339 nm in a-axis polarization using LBO crystal and between 1079 and 1341 nm in c-axis polarization using PPKTP crystal, respectively. At an incident pump power of 17.3 W, the maximum output power obtained at 593 nm and 598 nm is 0.18 W and 1.86 W, respectively. The laser experiment shows that Nd:YAP crystal can be used for an efficient diode-pumped dual-wavelength yellow laser system.

  1. Fire Source Localization Based on Distributed Temperature Sensing by a Dual-Line Optical Fiber System.

    PubMed

    Sun, Miao; Tang, Yuquan; Yang, Shuang; Li, Jun; Sigrist, Markus W; Dong, Fengzhong

    2016-06-06

    We propose a method for localizing a fire source using an optical fiber distributed temperature sensor system. A section of two parallel optical fibers employed as the sensing element is installed near the ceiling of a closed room in which the fire source is located. By measuring the temperature of hot air flows, the problem of three-dimensional fire source localization is transformed to two dimensions. The method of the source location is verified with experiments using burning alcohol as fire source, and it is demonstrated that the method represents a robust and reliable technique for localizing a fire source also for long sensing ranges.

  2. Fire Source Localization Based on Distributed Temperature Sensing by a Dual-Line Optical Fiber System

    PubMed Central

    Sun, Miao; Tang, Yuquan; Yang, Shuang; Li, Jun; Sigrist, Markus W.; Dong, Fengzhong

    2016-01-01

    We propose a method for localizing a fire source using an optical fiber distributed temperature sensor system. A section of two parallel optical fibers employed as the sensing element is installed near the ceiling of a closed room in which the fire source is located. By measuring the temperature of hot air flows, the problem of three-dimensional fire source localization is transformed to two dimensions. The method of the source location is verified with experiments using burning alcohol as fire source, and it is demonstrated that the method represents a robust and reliable technique for localizing a fire source also for long sensing ranges. PMID:27275822

  3. A 2.45 GHz electron cyclotron resonance proton ion source and a dual-lens low energy beam transporta)

    NASA Astrophysics Data System (ADS)

    Zhang, W. H.; Ma, H. Y.; Yang, Y.; Wu, Q.; Zhang, X. Z.; Wang, H.; Ma, B. H.; Feng, Y. C.; Fang, X.; Guo, J. W.; Cao, Y.; Li, X. X.; Zhu, Y. H.; Li, J. Y.; Sha, S.; Lu, W.; Lin, S. H.; Guo, X. H.; Zhao, H. Y.; Sun, L. T.; Xie, D. Z.; Peng, S. X.; Liu, Z. W.; Zhao, H. W.

    2012-02-01

    The structure and preliminary commissioning results of a new 2.45 GHz ECR proton ion source and a dual-lens low energy beam transport (LEBT) system are presented in this paper. The main magnetic field of the ion source is provided by a set of permanent magnets with two small electro-solenoid magnets at the injection and the extraction to fine tune the magnetic field for better microwave coupling. A 50 keV pulsed proton beam extracted by a three-electrode mechanism passes through the LEBT system of length of 1183 mm. This LEBT consists of a diagnosis chamber, two Glaser lenses, two steering magnets, and a final beam defining cone. A set of inner permanent magnetic rings is embedded in each of the two Glaser lenses to produce a flatter axial-field to reduce the lens aberrations.

  4. A 2.45 GHz electron cyclotron resonance proton ion source and a dual-lens low energy beam transport

    SciTech Connect

    Zhang, W. H.; Ma, H. Y.; Wu, Q.; Zhang, X. Z.; Wang, H.; Ma, B. H.; Feng, Y. C.; Fang, X.; Guo, J. W.; Li, X. X.; Zhu, Y. H.; Li, J. Y.; Guo, X. H.; Zhao, H. Y.; Sun, L. T.; Xie, D. Z.; Liu, Z. W.; Zhao, H. W.; Yang, Y.; Cao, Y.; and others

    2012-02-15

    The structure and preliminary commissioning results of a new 2.45 GHz ECR proton ion source and a dual-lens low energy beam transport (LEBT) system are presented in this paper. The main magnetic field of the ion source is provided by a set of permanent magnets with two small electro-solenoid magnets at the injection and the extraction to fine tune the magnetic field for better microwave coupling. A 50 keV pulsed proton beam extracted by a three-electrode mechanism passes through the LEBT system of length of 1183 mm. This LEBT consists of a diagnosis chamber, two Glaser lenses, two steering magnets, and a final beam defining cone. A set of inner permanent magnetic rings is embedded in each of the two Glaser lenses to produce a flatter axial-field to reduce the lens aberrations.

  5. Nitrate source apportionment using a combined dual isotope, chemical and bacterial property, and Bayesian model approach in river systems

    NASA Astrophysics Data System (ADS)

    Xia, Yongqiu; Li, Yuefei; Zhang, Xinyu; Yan, Xiaoyuan

    2017-01-01

    Nitrate (NO3-) pollution is a serious problem worldwide, particularly in countries with intensive agricultural and population activities. Previous studies have used δ15N-NO3- and δ18O-NO3- to determine the NO3- sources in rivers. However, this approach is subject to substantial uncertainties and limitations because of the numerous NO3- sources, the wide isotopic ranges, and the existing isotopic fractionations. In this study, we outline a combined procedure for improving the determination of NO3- sources in a paddy agriculture-urban gradient watershed in eastern China. First, the main sources of NO3- in the Qinhuai River were examined by the dual-isotope biplot approach, in which we narrowed the isotope ranges using site-specific isotopic results. Next, the bacterial groups and chemical properties of the river water were analyzed to verify these sources. Finally, we introduced a Bayesian model to apportion the spatiotemporal variations of the NO3- sources. Denitrification was first incorporated into the Bayesian model because denitrification plays an important role in the nitrogen pathway. The results showed that fertilizer contributed large amounts of NO3- to the surface water in traditional agricultural regions, whereas manure effluents were the dominant NO3- source in intensified agricultural regions, especially during the wet seasons. Sewage effluents were important in all three land uses and exhibited great differences between the dry season and the wet season. This combined analysis quantitatively delineates the proportion of NO3- sources from paddy agriculture to urban river water for both dry and wet seasons and incorporates isotopic fractionation and uncertainties in the source compositions.

  6. Recognition Memory zROC Slopes for Items with Correct versus Incorrect Source Decisions Discriminate the Dual Process and Unequal Variance Signal Detection Models

    ERIC Educational Resources Information Center

    Starns, Jeffrey J.; Rotello, Caren M.; Hautus, Michael J.

    2014-01-01

    We tested the dual process and unequal variance signal detection models by jointly modeling recognition and source confidence ratings. The 2 approaches make unique predictions for the slope of the recognition memory zROC function for items with correct versus incorrect source decisions. The standard bivariate Gaussian version of the unequal…

  7. Recognition Memory zROC Slopes for Items with Correct versus Incorrect Source Decisions Discriminate the Dual Process and Unequal Variance Signal Detection Models

    ERIC Educational Resources Information Center

    Starns, Jeffrey J.; Rotello, Caren M.; Hautus, Michael J.

    2014-01-01

    We tested the dual process and unequal variance signal detection models by jointly modeling recognition and source confidence ratings. The 2 approaches make unique predictions for the slope of the recognition memory zROC function for items with correct versus incorrect source decisions. The standard bivariate Gaussian version of the unequal…

  8. Dual-source CT in blunt trauma patients: elimination of diaphragmatic motion using high-pitch spiral technique.

    PubMed

    Liang, Teresa; McLaughlin, Patrick; Arepalli, Chesnal D; Louis, Luck J; Bilawich, Ana-Maria; Mayo, John; Nicolaou, Savvas

    2016-04-01

    The purpose of this study was to compare diaphragmatic motion on dual-source high-pitch (DS-HP) and conventional single-source (SS) CT scans in trauma patients. Seventy-five consecutive trauma patients who presented to a level one trauma center over a 6-month period were scanned with a standardized whole body trauma CT protocol including both DS-HP chest (pitch = 2.1-2.5) and SS abdominal CT scans. Subjective analysis of diaphragmatic motion was performed by two readers using a four-point motion scale in seven regions of the diaphragm on coronal and axial slices. An overall confidence score to exclude a diaphragmatic tear was determined (1 to 10, 10: completely confident and 1: impossible to exclude). Wilcoxon rank sum tests were used for statistical analysis, and p < 0.05 was considered significant. Mean confidence score of 9.85 for DS-HP was significantly better than the mean score of 7.66 for SS images (p < 0.0001). Diaphragmatic motion scores and subjective diaphragmatic motion artifact on coronal and axial images were significantly better for DS-HP images in all areas when compared individually (p < 0.0001) and overall (p < 0.0001). Regions of DS-HP (99.2 %) were diagnostic, whereas only 87.0 % % regions on SS were. Complete agreement of motion scores was present in 92 % of cases, with moderate overall agreement for confidence to exclude a diaphragmatic tear (κ = 0.45). Dual-source high-pitch CT scanning is advantageous as it allows for significantly better evaluation of diaphragmatic structures by minimizing motion artifacts on images of freely breathing trauma patients.

  9. Comparison of three dual-source remote sensing evapotranspiration models during the MUSOEXE-12 campaign: Revisit of model physics

    NASA Astrophysics Data System (ADS)

    Yang, Yuting; Long, Di; Guan, Huade; Liang, Wei; Simmons, Craig; Batelaan, Okke

    2015-05-01

    Various remote sensing-based terrestrial evapotranspiration (ET) models have been developed during the past four decades. These models vary in conceptual and mathematical representations of the physics, consequently leading to different performances. Examination of uncertainties associated with limitations in model physics will be useful for model selection and improvement. Here, three dual-source remote sensing ET models (i.e., the Hybrid dual-source scheme and Trapezoid framework-based ET Model (HTEM), the Two-Source Energy Balance (TSEB) model, and the MOD16 ET algorithm) using ASTER images were compared during the MUSOEXE-12 campaign in the Heihe River Basin in Northwest China, aiming to better understand the differences in model physics that potentially lead to differences in model performance. Model results were first compared against observations from a dense network of eddy covariance towers and isotope-based evaporation (E) and transpiration (T) partitioning. Results show that HTEM outperformed the other two models in simulating ET and its partitioning, whereas MOD16 performed worst (i.e., ET root-mean-square errors are 42.3 W/m2 (HTEM), 49.8 W/m2 (TSEB), and 95.3 W/m2 (MOD16)). On to model limitations, HTEM tends to underestimate ET under high advection due mostly to the underestimation of temperatures for the wet edge in its trapezoidal space. For TSEB, large uncertainties occur in determining the initial Priestley-Taylor coefficient and the iteration procedure for ET partitioning, leading to overestimation/underestimation of T/E in most cases, particularly over sparse vegetation. Primary use of meteorological data for MOD16 does not effectively capture the soil moisture restriction on ET, and therefore results in unreasonable spatial ET patterns.

  10. Determination of Jet Noise Radiation Source Locations using a Dual Sideline Cross-Correlation/Spectrum Technique

    NASA Technical Reports Server (NTRS)

    Allen, C. S.; Jaeger, S. M.

    1999-01-01

    The goal of our efforts is to extrapolate nearfield jet noise measurements to the geometric far field where the jet noise sources appear to radiate from a single point. To accomplish this, information about the location of noise sources in the jet plume, the radiation patterns of the noise sources and the sound pressure level distribution of the radiated field must be obtained. Since source locations and radiation patterns can not be found with simple single microphone measurements, a more complicated method must be used.

  11. Dual-source RF transmission in cardiac SSFP imaging at 3 T: systematic spatial evaluation of image quality improvement compared to conventional RF transmission.

    PubMed

    Rasper, Michael; Gramer, Bettina M; Settles, Marcus; Laugwitz, Karl-Ludwig; Ibrahim, Tareq; Rummeny, Ernst J; Huber, Armin

    2015-01-01

    The purpose of this investigation was to systematically evaluate the spatial distribution of image quality improvement with dual-source radiofrequency (RF) transmission in cardiac steady-state free precession sequences at 3.0 T. Imaging with and without dual-source RF transmission was performed in 30 patients. Contrast-to-noise ratio for the left ventricular myocardium was significantly higher using dual-source RF transmission, but improvement was not uniformly distributed. The posterior myocardium showed significantly less contrast-to-noise ratio gain than all other cardiac regions. Signal-to-noise ratio increase was higher in the right than in the left ventricle. Subjective image quality was significantly enhanced by parallel RF transmission.

  12. Emission sources and atmospheric processing of carbonaceous aerosols in India and China: Insights from dual carbon isotope techniques

    NASA Astrophysics Data System (ADS)

    Andersson, A.; Kirillova, E. N.; Bosch, C.; Suresh, T.; Lee, M.; Du, K.; Sheesley, R. J.; Budhavant, K.; Gustafsson, O. M.

    2013-12-01

    The large emissions of carbonaceous aerosols, e.g., black carbon (BC), in India and China have detrimental effects on both human health and the regional climate. However, mitigation efforts as well as accurate modeling of these effects are currently hampered by large uncertainties regarding the contributions from different emission sources, including both primary and secondary processes. Here, we present dual carbon isotope constraints on emissions sources and atmospheric processing from multiple sites capturing the outflow from India and China. Radiocarbon (14C) studies of elemental carbon (EC) - a tracer for BC - show larger relative fossil contributions than expected from bottom-up emission inventories, for both India (49+-5) and China (80 +-6%). Similarly to EC, radiocarbon constraints of water soluble organic carbon (WSOC) shows substantially larger relative fossil contributions in Chinese outflow (30-50%) as compared with India, but also compared to Europe and USA (10-20%). In contrast to the radiocarbon data, stable carbon (d13C) analysis of WSOC shows substantial variability for different sites capturing the Indian outflow. Strong enrichment of heavy isotopes in WSOC is coupled to expected transport time from sources, indicating the influence of photochemical aging during transport. Such trends in the d13C signature are not observed for the EC fraction. Taken together this work show that carbon isotope techniques provide firm constraints on emission sources of different fractions of carbonaceous aerosols, and may also offer insights into atmospheric processing of these constituents during air mass transport.

  13. Estimated radiation dose and image quality comparison of the scan protocols in dual-source computed tomography coronary angiography.

    PubMed

    Karaarslan, Ercan; Ulus, Sıla; Bavbek, Cengiz

    2013-08-01

    Radiation exposure from computed tomography coronary angiography (CTCA) is of particular concern and several techniques have been introduced to lower the radiation dose. In this study, we aimed to compare the diagnostic image quality and estimated radiation dose of the three CTCA acquisition protocols in a recently introduced second generation dual-source computed tomography. Two hundred consecutive subjects underwent dual-source CTCA by using high-pitch spiral, sequential and retrospective spiral protocols. Effective radiation dose, expressed in millisieverts, was calculated as the product of the dose-length product times a conversion factor of 0.014. Image quality was evaluated on a per-segment basis, with a four-point scale. For the high-pitch spiral, sequential and retrospective spiral protocols, mean effective radiation doses were 1.41 ± 0.56, 5.50 ± 2.06 and 7.79 ± 2.25 mSv and mean per-subject image scores were 2.8 ± 0.7, 2.2 ± 0.8 and 2.5 ± 0.8, respectively. Radiation dose of the high-pitch mode was significantly lower (P < 0.001) than the sequential and retrospective spiral modes, and statistical analysis for image quality revealed a significant difference between the high-pitch spiral and the sequential modes (P < 0.05). Dual-source CTCA using high-pitch acquisition considerably lowers radiation exposure in subjects with a low and stable heart rate and maintains good image quality, especially when the subjects have a body mass index ≤25 and a tube voltage of 80 or 100 kV is used. However, when sequential and retrospective spiral modes are used in the same device, mean radiation doses can increase roughly three and five times more, respectively. © 2013 The Authors. Journal of Medical Imaging and Radiation Oncology © 2013 The Royal Australian and New Zealand College of Radiologists.

  14. Low tube voltage dual source computed tomography to reduce contrast media doses in adult abdomen examinations: A phantom study

    SciTech Connect

    Thor, Daniel; Brismar, Torkel B. Fischer, Michael A.

    2015-09-15

    Purpose: To evaluate the potential of low tube voltage dual source (DS) single energy (SE) and dual energy (DE) computed tomography (CT) to reduce contrast media (CM) dose in adult abdominal examinations of various sizes while maintaining soft tissue and iodine contrast-to-noise ratio (CNR). Methods: Four abdominal phantoms simulating a body mass index of 16 to 35 kg/m{sup 2} with four inserted syringes of 0, 2, 4, and 8 mgI/ml CM were scanned using a 64-slice DS-CT scanner. Six imaging protocols were used; one single source (SS) reference protocol (120 kV, 180 reference mAs), four low kV SE protocols (70 and 80 kV using both SS and DS), and one DE protocol at 80/140 kV. Potential CM reduction with unchanged CNRs relative to the 120 kV protocol was calculated along with the corresponding increase in radiation dose. Results: The potential contrast media reductions were determined to be approximately 53% for DS 70 kV, 51% for SS 70 kV, 44% for DS 80 kV, 40% for SS 80 kV, and 20% for DE (all differences were significant, P < 0.05). Constant CNR could be achieved by using DS 70 kV for small to medium phantom sizes (16–26 kg/m{sup 2}) and for all sizes (16–35 kg/m{sup 2}) when using DS 80 kV and DE. Corresponding radiation doses increased by 60%–107%, 23%–83%, and 6%–12%, respectively. Conclusions: DS single energy CT can be used to reduce CM dose by 44%–53% with maintained CNR in adult abdominal examinations at the cost of an increased radiation dose. DS dual-energy CT allows reduction of CM dose by 20% at similar radiation dose as compared to a standard 120 kV single source.

  15. Radiation dose levels in pediatric chest CT: experience in 499 children evaluated with dual-source single-energy CT.

    PubMed

    Martine, Remy-Jardin; Santangelo, Teresa; Colas, Lucie; Jean-Baptiste, Faivre; Duhamel, Alain; Deschildre, Antoine; Remy, Jacques

    2017-02-01

    The availability of dual-source technology has introduced the possibility of scanning children at lower kVp with a high-pitch mode, combining high-speed data acquisition and high temporal resolution. To establish the radiation dose levels of dual-source, single-energy chest CT examinations in children. We retrospectively recorded the dose-length product (DLP) of 499 consecutive examinations obtained in children <50 kg, divided into five weight groups: group 1 (<10 kg, n = 129); group 2 (10-20 kg, n = 176); group 3 (20-30 kg, n = 99), group 4 (30-40 kg, n = 58) and group 5 (40-49 kg, n = 37). All CT examinations were performed with high temporal resolution (75 ms), a high-pitch mode and a weight-adapted selection of the milliamperage. CT examinations were obtained at 80 kVp with a milliamperage ranging between 40 mAs and 90 mAs, and a pitch of 2.0 (n = 162; 32.5%) or 3.0 (n = 337; 67.5%). The mean duration of data acquisition was 522.8 ± 192.0 ms (interquartile range 390 to 610; median 490). In the study population, the mean CT dose index volume (CTDIvol32) was 0.83 mGy (standard deviation [SD] 0.20 mGy; interquartile range 0.72 to 0.94; median 0.78); the mean DLP32 was 21.4 mGy.cm (SD 9.1 mGy.cm; interquartile range 15 to 25; median 19.0); and the mean size-specific dose estimate (SSDE) was 1.7 mGy (SD 0.4 mGy; interquartile range 1.5 to 1.9; median 1.7). The DLP32, CTDIvol32 and SSDE were found to be statistically significant in the five weight categories (P < 0.0001). This study establishes the radiation dose levels for dual-source, single-kVp chest CT from a single center. In the five weight categories, the median values varied 15-37 mGy.cm for the DLP32, 0.78-1.25 mGy for the CTDIvol32 and 1.6-2.1 mGy for the SSDE.

  16. Effectiveness of Using Dual-source CT and the Upshot it creates on Both Heart Rate and Image Quality

    PubMed Central

    Selçuk, Tuba; Otçu, Hafize; Yüceler, Zeyneb; Bilgili, Çiğdem; Bulakçı, Mesut; Savaş, Yıldıray; Çelik, Ömer

    2016-01-01

    Background: Early detection of coronary artery disease (CAD) is important because of the high morbidity and mortality rates. As invasive coronary angiography (ICA) is an invasive procedure, an alternative diagnostic method; coronary computed tomography angiography (CTA), has become more widely used by the improvements in detector technology. Aims: In this study, we aimed to examine the accuracy and image quality of high-pitch 128-slice dual-source CTA taking the ICA as reference technique. We also aimed to compare the accuracy and image quality between different heart rate groups of >70 beates per minute (bpm) and ≤70 bpm. Study Design: Retrospective cross-sectional study. Methods: Among 450 patients who underwent coronary CTA with the FLASH spiral technique, performed with a second generation dual-source computed tomography device with a pitch value of 3.2, 102 patients without stent and/or bypass surgery history and clinically suspected coronary artery disease who underwent ICA within 15 days were enrolled. Image quality was assessed by two independent radiologists using a 4-point scale (1=absence of any artifacts- 4=non-evaluable). A stenosis >50% was considered significant on a per-segment, per-vessel, and per-patient basis and ICA was considered the reference method. Radiation doses were determined using dose length product (DLP) values detected by the computed tomography (CT) device. In addition, patients were classified into two groups according to their heart rates as ≤70 bpm (73 patients) and >70 bpm (29 patients). The relation between the diagnostic accuracy and heart rate groups were evaluated. Results: Overall, 1495 (98%) coronary segments were diagnostic in 102 patients (32 male, 70 female, mean heart rate: 65 bpm). There was a significant correlation between image quality and mean heart rate in the right coronary artery (RCA) segments. The effective radiation dose was 0.98±0.09 mili Sievert (mSv). On a per-patient basis, sensitivity, specificity

  17. Controllable time dependent and dual band emission infrared source to test missile warning systems in flight

    NASA Astrophysics Data System (ADS)

    Cabib, Dario; Davidzon, Larry; Gil, Amir

    2008-10-01

    Proliferation and technological progress of Mid Wave Infrared (MWIR) sensors for Missile Warning Systems (MWS)1,2 and increased sophistication of countermeasures require demanding in-flight testing. The IR sensors are becoming more sensitive for longer range of detection, the spatial resolution is improving for better target detection and identification, spectral discrimination is being introduced for lower False Alarm Rate (FAR), and the imaging frame rate is increasing for faster defensive reaction. As a result, testing a complex MWS/countermeasure system performance before deployment requires ever more realistic simulation of the threats in their natural backgrounds, and faster measurement of the radiometric output, directionality and time response of the countermeasures. In a previous paper3 we have described a system (IRTS or Infrared Threat Stimulator) we developed to test missile warning systems (MWS) mounted on an aircraft. The IRTS is placed in the field and projects a time dependent infrared beam toward the flying aircraft. The time dependent intensity of the beam simulates the infrared emittance of an approaching missile in the 3 to 5 micron spectral range as sensed by an MWS system. Now we have developed a new system based on the IRTS concept allowing the user to separately control the time profiles of two different infrared ranges independently within the 3 to 5 micron range. This is important because MWS instrumentation now has higher spectral discrimination capability in order to be more missile-specific and less prone to be confused by clutter and background signals. In this paper we describe the new dual band IRTS system and its capability (or Dual Color IRTS, DCIRTS).

  18. Utilization of dual-source X-ray tomography for reduction of scanning time of wooden samples

    NASA Astrophysics Data System (ADS)

    Fíla, T.; Kumpová, I.; Jandejsek, I.; Kloiber, M.; Tureček, D.; Vavřík, D.

    2015-05-01

    We present a novel dual-source/dual energy (DSCT/DECT) micro-tomography system including results of high-resolution DSCT reconstruction. The DSCT micro-tomography setup was designed as a multi-purpose X-ray imaging device equipped with two pairs of X-ray tubes and detectors in orthogonal arrangement with independent control of beam parameters. Both pairs (tube-detector) are mounted on a computer numerical control positioning system and can be independently set up to different geometries (e.g. with different magnification of each pair). In this work the simultaneous scanning of the object by two tube-detector pairs was used for approximately half reduction of tomography scanning time. The developed imaging procedure was applied for scanning of a wooden sample locally damaged during a semi-destructive test for assessment of wood quality. Prior to the tomography measurements the setup geometry was precisely adjusted in terms of magnification, horizontal and vertical tube-specimen-detector alignment of both pairs. DSCT measurements were carried out in sequence (2 × 90° for each tube) with identical 100μm image resolution. It was proven that the presented experimental setup combined with appropriate control technique significantly reduces tomography scanning time of materials with complex micro-structure.

  19. Dual Nitrate Isotopes in Dry Deposition: Utility for Partitioning Nox Source Contributions to Landscape Nitrogen Deposition

    EPA Science Inventory

    Dry deposition is a major component of total nitrogen deposition and thus an important source of bioavailable nitrogen to ecosystems. However, relative to wet deposition, less is known regarding the sources and spatial variability of dry deposition. This is in part due to diffi...

  20. The impact of dual-source parallel radiofrequency transmission with patient-adaptive shimming on the cardiac magnetic resonance in children at 3.0 T

    PubMed Central

    Wang, Haipeng; Qiu, Liyun; Wang, Guangbin; Gao, Fei; Jia, Haipeng; Zhao, Junyu; Chen, Weibo; Wang, Cuiyan; Zhao, Bin

    2017-01-01

    Abstract The cardiac magnetic resonance (CMR) of children at 3.0 T presents a unique set of technical challenges because of their small cardiac anatomical structures, fast heart rates, and the limited ability to keep motionless and hold breathe, which could cause problems associated with field inhomogeneity and degrade the image quality. The aim of our study was to evaluate the effect of dual-source parallel radiofrequency (RF) transmission on the B1 homogeneity and image quality in children with CMR at 3.0 T. The study was approved by the institutional ethics committee and written informed consent was obtained. A total of 30 free-breathing children and 30 breath-hold children performed CMR examinations with dual-source and single-source RF transmission. The B1 homogeneity, contrast ratio (CR) of cine images, and off-resonance artifacts in cine images between dual-source and single-source RF transmission were assessed in free-breathing and breath-hold groups, respectively. In both free-breathing and breath-hold groups, higher mean percentage of flip angle (free-breathing group: 104.2 ± 4.6 vs 95.5 ± 6.3, P < .001; breath-hold group: 101.5 ± 5.1 vs 92.5 ± 6.3, P < .001) and lower coefficient of variation (free-breathing group: 0.06 ± 0.02 vs 0.09 ± 0.03, P < .001; breath-hold group: 0.07 ± 0.03 vs 0.10 ± 0.04, P = .005) were found with dual-source than with single-source RF transmission. Both the CRs in the horizontal long axis (HLA) and short axis of cine images with dual-source RF transmission was improved (P < .05 for all). The scores of off-resonance artifacts in the HLA with dual-source RF transmission were higher in both free-breathing and breath-hold groups (P < .05 for all), with substantial interreader agreement (kappa values from 0.68 to 0.74). Compared with conventional single-source, dual-source parallel RF transmission could significantly improve the B1 homogeneity and image quality for

  1. Dual isotope notch observer for isotope identification, assay and imaging with mono-energetic gamma-ray sources

    DOEpatents

    Barty, Christopher P.J.

    2013-02-05

    A dual isotope notch observer for isotope identification, assay and imaging with mono-energetic gamma-ray sources includes a detector arrangement consists of three detectors downstream from the object under observation. The latter detector, which operates as a beam monitor, is an integrating detector that monitors the total beam power arriving at its surface. The first detector and the middle detector each include an integrating detector surrounding a foil. The foils of these two detectors are made of the same atomic material, but each foil is a different isotope, e.g., the first foil may comprise U235 and second foil may comprise U238. The integrating detectors surrounding these pieces of foil measure the total power scattered from the foil and can be similar in composition to the final beam monitor. Non-resonant photons will, after calibration, scatter equally from both foils.

  2. A tunable dual-wavelength pump source based on simulated polariton scattering for terahertz-wave generation

    NASA Astrophysics Data System (ADS)

    Sun, Bo; Liu, Jinsong; Yao, Jianquan; Li, Enbang

    2013-11-01

    We propose a dual-wavelength pump source by utilizing stimulated polariton scattering in a LiNbO3 crystal. The residual pump and the generated tunable Stokes waves can be combined to generate THz-wave generation via difference frequency generation (DFG). With a pump energy of 49 mJ, Stokes waves with a tuning range from 1067.8 to 1074 nm have been generated, and an output energy of up to 14.9 mJ at 1070 nm has been achieved with a conversion efficiency of 21.7%. A sum frequency generation experiment was carried out to demonstrate the feasibility of the proposed scheme for THz-wave DFG.

  3. Sources of Nitrogen to Streams of Varying Land Use as Determined Through Dual Isotope Analysis of Nitrate

    NASA Astrophysics Data System (ADS)

    Elliott, E. M.; Burns, D. A.; Boyer, E. W.; Kendall, C.

    2006-12-01

    Inputs of reactive nitrogen (N) to watersheds in the northeastern USA are linked to environmental concerns such as acidification of upland ecosystems, accumulation of N in groundwater, and eutrophication of coastal waterways. Nitrogen sources include atmospheric deposition, fertilizer, and human and animal waste, and the relative strength of these sources has been shown to vary with watershed land use. Attribution of N sources is important in developing effective policy strategies for reducing N loads in streams and rivers. Here, we use dual (δ15N, δ18O) isotope analysis of nitrate as well as chemistry data from six streams in New York to determine dominant sources of N and to learn more about how N cycles through these watersheds. Land use in these watersheds included 100% forested land in each of two streams in the Catskill and Adirondack Mountains, 34 to 70% agricultural land (primarily dairy farms) in three streams, and 56% suburban land in one stream. Nitrate in atmospheric deposition had δ18O values that ranged from about +65 to +85‰ in precipitation and a similar range in dry deposition, and δ15N values that ranged from about -5 to +5‰ in precipitation and about -2 to +15‰ in dry deposition. Nitrate in stream water from the dominantly forested watersheds had δ18O values that ranged from +5 to +15‰, indicating that the dominant immediate source was from nitrification in soils, but with a tendency towards higher direct contributions of atmospheric nitrate during high flow. The two streams with the highest percent of agricultural land use had isotope values that indicated a mixture of nitrate sources from soil nitrification and animal waste. These data fall along a line with a δ18O:δ15N slope of 1:2 indicating a varying source that was denitrified. Nitrate in the watershed dominated by suburban land use had δ18O values as high as +30‰, indicating a large direct contribution of atmospheric nitrate transported over impervious surfaces and

  4. Automatic selection of an optimal systolic and diastolic reconstruction windows for dual-source CT coronary angiography

    NASA Astrophysics Data System (ADS)

    Seifarth, H.; Puesken, M.; Wienbeck, S.; Maintz, D.; Heindel, W.; Juergens, K.-U.

    2008-03-01

    Purpose: To assess the performance of a motion map algorithm to automatically determine the optimal systolic and diastolic reconstruction window for coronary CT Angiography using Dual Source CT. Materials and Methods: Dual Source coronary CT angiography data sets (Somatom Definition, Siemens Medical Solutions) from 50 consecutive patients were included in the analysis. Optimal systolic and diastolic reconstruction windows were determined using a motion map algorithm (BestPhase, Siemens Medical Solutions). Additionally data sets were reconstructed in 5% steps throughout the RR-interval. For each major vessel (RCA, LAD and LCX) an optimal systolic and diastolic reconstruction window was manually determined by two independent readers using volume rendering displays. Image quality was rated using a five-point scale (1 = no motion artifacts, 5 = severe motion artifacts over entire length of the vessel). Results: The mean heart rate during the scan was 72.4bpm (+/-15.8bpm). Median systolic and diastolic reconstruction windows using the BestPhase algorithm were at 37% and 73% RR. The median manually selected systolic reconstruction window was 35 %, 30% and 35% for RCA, LAD, and LCX. For all vessels the median observer selected diastolic reconstruction window was 75%. Mean image quality using the BestPhase algorithm was 2.4 +/-0.9 for systolic reconstructions and 1.9 +/-1.1 for diastolic reconstructions. Using the manual approach, the mean image quality was 1.9 +/-0.5 and 1.7 +/-0.8 respectively. There was a significant difference in image quality between automatically and manually determined systolic reconstructions (p<0.01) but there was no significant difference in image quality in diastolic reconstructions. Conclusion: Automatic determination of the optimal reconstruction interval using the BestPhase algorithm is feasible and yields reconstruction windows similar to observer selected reconstruction windows. In diastolic reconstructions overall image quality is similar

  5. Influence of cardiac motion on stent lumen visualization in third generation dual-source CT employing a pulsatile heart model.

    PubMed

    Petri, Nils; Gassenmaier, Tobias; Allmendinger, Thomas; Flohr, Thomas; Voelker, Wolfram; Bley, Thorsten A

    2017-02-01

    To detect an in-stent restenosis, an invasive coronary angiography is commonly performed. Owing to the risk associated with this procedure, a non-invasive method to detect or exclude an in-stent restenosis is desirable. The purpose of this study was to evaluate the influence of cardiac motion on stent lumen visibility in a third-generation dual-source CT scanner (SOMATOM Force; Siemens Healthcare, Forchheim, Germany), employing a pulsatile heart model (CoroSim(®); Mecora, Aachen, Germany). 13 coronary stents with a diameter of 3.0 mm were implanted in plastic tubes filled with a contrast medium and then fixed onto the pulsatile phantom heart model. The scans were performed while the heart model mimicked the heartbeat. Coronary stents were scanned in an orientation parallel to the scanner z-axis. The evaluation of the stents was performed by employing a medium sharp convolution kernel optimized for vascular imaging. The mean visible stent lumen was reduced from 65.6 ± 5.7% for the stents at rest to 60.8 ± 4.4% for the stents in motion (p-value: <0.001). While the difference in lumen visibility between stents in motion and at rest was significant, the use of this third-generation dual-source CT scanner enabled a high stent lumen visibility under the influence of cardiac motion. Whether this translates into a clinical setting has to be evaluated in further patient studies. Advances in knowledge: The employed modern CT scanner enables a high stent lumen visibility even under the influence of cardiac motion, which is important to detect or exclude an in-stent restenosis.

  6. Incremental Value of Adenosine-induced Stress Myocardial Perfusion Imaging with Dual-Source CT at Cardiac CT Angiography1

    PubMed Central

    Rocha-Filho, Jose A.; Blankstein, Ron; Shturman, Leonid D.; Bezerra, Hiram G.; Okada, David R.; Rogers, Ian S.; Ghoshhajra, Brian; Hoffmann, Udo; Feuchtner, Gudrun; Mamuya, Wilfred S.; Brady, Thomas J.

    2010-01-01

    Purpose: First, to assess the feasibility of a protocol involving stress-induced perfusion evaluated at computed tomography (CT) combined with cardiac CT angiography in a single examination and second, to assess the incremental value of perfusion imaging over cardiac CT angiography in a dual-source technique for the detection of obstructive coronary artery disease (CAD) in a high-risk population. Materials and Methods: Institutional review board approval and informed patient consent were obtained before patient enrollment in the study. The study was HIPAA compliant. Thirty-five patients at high risk for CAD were prospectively enrolled for evaluation of the feasibility of CT perfusion imaging. All patients underwent retrospectively electrocardiographically gated (helical) adenosine stress CT perfusion imaging followed by prospectively electrocardiographically gated (axial) rest myocardial CT perfusion imaging. Analysis was performed in three steps: (a)Coronary arterial stenoses were scored for severity and reader confidence at cardiac CT angiography, (b)myocardial perfusion defects were identified and scored for severity and reversibility at CT perfusion imaging, and (c)coronary stenosis severity was reclassified according to perfusion findings at combined cardiac CT angiography and CT perfusion imaging. The sensitivity, specificity, negative predictive value (NPV), and positive predictive value (PPV) of cardiac CT angiography before and after CT perfusion analysis were calculated. Results: With use of a reference standard of greater than 50% stenosis at invasive angiography, all parameters of diagnostic accuracy increased after CT perfusion analysis: Sensitivity increased from 83% to 91%; specificity, from 71% to 91%; PPV, from 66% to 86%; and NPV, from 87% to 93%. The area under the receiver operating characteristic curve increased significantly, from 0.77 to 0.90 (P < .005). Conclusion: A combination protocol involving adenosine perfusion CT imaging and cardiac

  7. Diagnostic accuracy of 128-slice dual-source CT coronary angiography: a randomized comparison of different acquisition protocols.

    PubMed

    Neefjes, Lisan A; Rossi, Alexia; Genders, Tessa S S; Nieman, Koen; Papadopoulou, Stella L; Dharampal, Anoeshka S; Schultz, Carl J; Weustink, Annick C; Dijkshoorn, Marcel L; Ten Kate, Gert-Jan R; Dedic, Admir; van Straten, Marcel; Cademartiri, Filippo; Hunink, M G Myriam; Krestin, Gabriël P; de Feyter, Pim J; Mollet, Nico R

    2013-03-01

    To compare the diagnostic performance and radiation exposure of 128-slice dual-source CT coronary angiography (CTCA) protocols to detect coronary stenosis with more than 50 % lumen obstruction. We prospectively included 459 symptomatic patients referred for CTCA. Patients were randomized between high-pitch spiral vs. narrow-window sequential CTCA protocols (heart rate below 65 bpm, group A), or between wide-window sequential vs. retrospective spiral protocols (heart rate above 65 bpm, group B). Diagnostic performance of CTCA was compared with quantitative coronary angiography in 267 patients. In group A (231 patients, 146 men, mean heart rate 58 ± 7 bpm), high-pitch spiral CTCA yielded a lower per-segment sensitivity compared to sequential CTCA (89 % vs. 97 %, P = 0.01). Specificity, PPV and NPV were comparable (95 %, 62 %, 99 % vs. 96 %, 73 %, 100 %, P > 0.05) but radiation dose was lower (1.16 ± 0.60 vs. 3.82 ± 1.65 mSv, P < 0.001). In group B (228 patients, 132 men, mean heart rate 75 ± 11 bpm), per-segment sensitivity, specificity, PPV and NPV were comparable (94 %, 95 %, 67 %, 99 % vs. 92 %, 95 %, 66 %, 99 %, P > 0.05). Radiation dose of sequential CTCA was lower compared to retrospective CTCA (6.12 ± 2.58 vs. 8.13 ± 4.52 mSv, P < 0.001). Diagnostic performance was comparable in both groups. Sequential CTCA should be used in patients with regular heart rates using 128-slice dual-source CT, providing optimal diagnostic accuracy with as low as reasonably achievable (ALARA) radiation dose.

  8. Application of polycapillary optics for dual energy spectroscopy based on a laboratory source

    NASA Astrophysics Data System (ADS)

    Cherepennikov, Yu.; Miloichikova, I.; Gogolev, A.; Stuchebrov, S.; Hampai, D.; Dabagov, S.; Liedl, A.

    2017-07-01

    This paper describes experimental investigation aimed at the development of X-ray tube based source with a spectrum characterized by two different monochromatic lines (double-line spectrum). The modification of the tube spectrum to be a double-line one is suggested by means of a two crystals kit. The possibility to increase the beam intensity was experimentally studied via the use of a polycapillary semilens that collects divergent X-ray radiation from the source.

  9. Compact and portable terahertz source based on frequency mixing using dual-frequency solid-state laser

    NASA Astrophysics Data System (ADS)

    Ding, Yujie J.; Zhao, Pu; Li, Da

    2012-03-01

    We review the recent progress made by us on power scaling of terahertz (THz) waves and development of compact and portable THz sources. By reversely stacking GaP plates, we were able to improve the photon conversion efficiency from 25% to 40%, which is the record-high value. As the number of the stacked GaP plates was increased from 4 to 5, the output power was decreased. This is the evidence on back conversion. In order to make our THz source truly compact and portable, we investigated a new route to THz generation by mixing two frequencies generated by a single Nd:YLF solid-state laser. After two Nd:YLF crystals were introduced in the laser cavity, the output power was scaled up to 4.5 μW. Such a configuration exhibits versatile characteristics such as the generation of different THz frequencies by combining two different laser crystals. Our recent investigation of THz generation based on passively Q-switched dual-frequency pulses may help us with further reducing the dimension of our compact and portable THz source.

  10. Modeling of single event transients with dual double-exponential current sources: Implications for logic cell characterization

    DOE PAGES

    Black, Dolores Archuleta; Robinson, William H.; Wilcox, Ian Zachary; ...

    2015-08-07

    Single event effects (SEE) are a reliability concern for modern microelectronics. Bit corruptions can be caused by single event upsets (SEUs) in the storage cells or by sampling single event transients (SETs) from a logic path. Likewise, an accurate prediction of soft error susceptibility from SETs requires good models to convert collected charge into compact descriptions of the current injection process. This paper describes a simple, yet effective, method to model the current waveform resulting from a charge collection event for SET circuit simulations. The model uses two double-exponential current sources in parallel, and the results illustrate why a conventionalmore » model based on one double-exponential source can be incomplete. Furthermore, a small set of logic cells with varying input conditions, drive strength, and output loading are simulated to extract the parameters for the dual double-exponential current sources. As a result, the parameters are based upon both the node capacitance and the restoring current (i.e., drive strength) of the logic cell.« less

  11. Modeling of single event transients with dual double-exponential current sources: Implications for logic cell characterization

    SciTech Connect

    Black, Dolores Archuleta; Robinson, William H.; Wilcox, Ian Zachary; Limbrick, Daniel B.; Black, Jeffrey D.

    2015-08-07

    Single event effects (SEE) are a reliability concern for modern microelectronics. Bit corruptions can be caused by single event upsets (SEUs) in the storage cells or by sampling single event transients (SETs) from a logic path. Likewise, an accurate prediction of soft error susceptibility from SETs requires good models to convert collected charge into compact descriptions of the current injection process. This paper describes a simple, yet effective, method to model the current waveform resulting from a charge collection event for SET circuit simulations. The model uses two double-exponential current sources in parallel, and the results illustrate why a conventional model based on one double-exponential source can be incomplete. Furthermore, a small set of logic cells with varying input conditions, drive strength, and output loading are simulated to extract the parameters for the dual double-exponential current sources. As a result, the parameters are based upon both the node capacitance and the restoring current (i.e., drive strength) of the logic cell.

  12. Experimental and theoretical studies of dual energy subtraction angiography (DESA) performed using laser-based x-ray source

    NASA Astrophysics Data System (ADS)

    Krol, Andrzej; Kieffer, Jean-Claude; Ichalalene, Zahia; Jiang, Zhiming; Chamberlain, Charles C.; Scalzetti, Ernest M.

    2001-11-01

    Two types of x-ray sources for dual energy subtraction angiography (DESA), laser-based and conventional, were investigated. A Tabletop Terawatt laser was used to create x-ray source with Ba, La, Nd, Gd, and Ce targets. A theoretical model of image quality was developed. A Figure of Merit, FOM equals SNR./(integral dose)1/2, was obtained. Images of an angiographic contrast detail phantom were obtained using laser-driven x-ray source in DESA regime and a standard angiography unit in DSA regime. The log-signals due to Iodine contrast agent in the images were measured and compared with the theoretical model predictions. The integral dose was estimated. We found that the La and Ba lines extracted by a monochromator are optimal for imaging Iodine contrast with laser-based DESA. In this case, SNR exhibits three- to five-fold improvement, as compared to SNR expected for a tube-based DESA system. Consequently, dose utilization, as defined by FOM, improves by factor of two to three, depending on patient thickness and scatter conditions. When only filters are used, SNR and FOM due to laser-based system are comparable to those due to tube-based DESA. In this case, preferable target/filter combination for the laser system is Ba/I and Ce/Nd for the low- and high-beam, respectively.

  13. 450 mm dual frequency capacitively coupled plasma sources: Conventional, graded, and segmented electrodes

    SciTech Connect

    Yang Yang; Kushner, Mark J.

    2010-12-01

    Wafer diameters for microelectronics fabrication will soon transition from 300 to 450 mm at a time when excitation frequencies for capacitively coupled plasmas (CCPs) are increasing to 200 MHz or higher. Already for 300 mm tools, there is evidence that wave behavior (i.e., propagation, constructive, and destructive interference) affects the uniformity of processing. The increase in diameter to 450 mm is likely to exacerbate these effects, perhaps requiring nontraditional tool designs. This is particularly important in dual frequency (DF) CCP tools in which there are potential interactions between frequencies. In this paper, results from a two-dimensional computational investigation of Ar plasma properties in a 450 mm DF-CCP reactor, incorporating a full-wave solution of Maxwell's equations, are discussed. As in 300 mm DF-CCP reactors, the electron density collapses toward the center of the reactor with increasing high frequency (HF), however, with more pronounced finite wavelength effects. Graded conductivity electrodes with multilayer of dielectrics are computationally demonstrated as a possible means to suppress wave effects thereby increasing plasma uniformity. Segmentation of the HF electrode also improves the plasma uniformity by making the electrical distance between the feeds and the sheath edges as uniform as possible.

  14. A dual neutron/gamma source for the Fissmat Inspection for Nuclear Detection (FIND) system.

    SciTech Connect

    Doyle, Barney Lee; King, Michael; Rossi, Paolo; McDaniel, Floyd Del; Morse, Daniel Henry; Antolak, Arlyn J.; Provencio, Paula Polyak; Raber, Thomas N.

    2008-12-01

    Shielded special nuclear material (SNM) is very difficult to detect and new technologies are needed to clear alarms and verify the presence of SNM. High-energy photons and neutrons can be used to actively interrogate for heavily shielded SNM, such as highly enriched uranium (HEU), since neutrons can penetrate gamma-ray shielding and gamma-rays can penetrate neutron shielding. Both source particles then induce unique detectable signals from fission. In this LDRD, we explored a new type of interrogation source that uses low-energy proton- or deuteron-induced nuclear reactions to generate high fluxes of mono-energetic gammas or neutrons. Accelerator-based experiments, computational studies, and prototype source tests were performed to obtain a better understanding of (1) the flux requirements, (2) fission-induced signals, background, and interferences, and (3) operational performance of the source. The results of this research led to the development and testing of an axial-type gamma tube source and the design/construction of a high power coaxial-type gamma generator based on the {sup 11}B(p,{gamma}){sup 12}C nuclear reaction.

  15. Dual-Carbon sources fuel the OCS deep-reef Community, a stable isotope investigation

    USGS Publications Warehouse

    Sulak, Kenneth J.; Berg, J.; Randall, Michael; Dennis, George D.; Brooks, R.A.

    2008-01-01

    The hypothesis that phytoplankton is the sole carbon source for the OCS deep-reef community (>60 m) was tested. Trophic structure for NE Gulf of Mexico deep reefs was analyzed via carbon and nitrogen stable isotopes. Carbon signatures for 114 entities (carbon sources, sediment, fishes, and invertebrates) supported surface phytoplankton as the primary fuel for the deep reef. However, a second carbon source, the macroalga Sargassum, with its epiphytic macroalgal associate, Cladophora liniformis, was also identified. Macroalgal carbon signatures were detected among 23 consumer entities. Most notably, macroalgae contributed 45 % of total carbon to the 13C isotopic spectrum of the particulate-feeding reef-crest gorgonian Nicella. The discontinuous spatial distribution of some sessile deep-reef invertebrates utilizing pelagic macroalgal carbon may be trophically tied to the contagious distribution of Sargassum biomass along major ocean surface features.

  16. Numerical simulation of a dual-source supersonic plasma jet expansion process: continuum approach

    NASA Astrophysics Data System (ADS)

    Pal, Subrata; Dey, Subhrajit; Miebach, Thomas

    2007-05-01

    Expanding thermal plasma (ETP) is a versatile technology for thin film deposition process with directional plasma flux and high deposition rates. This process involves expansion of supersonic plasma jets through a steep pressure ratio into a chamber maintained at near vacuum. Usually the plasma jets deviate from chemical and thermal equilibrium and the continuum approach is insufficient to describe the phenomena. In the current work, the continuum approach based Navier-Stokes equations have been implemented to study and understand the jet expansion process in a typical dual-arc plasma deposition reactor. The numerical predictions have been compared against in-house experimental data obtained by thermocouple measurements. For the range of back pressures (6-200 Pa) considered, it was observed that the jet core is supersonic and transitions to a subsonic zone downstream without the formation of any Mach disc for the prevalent operating parameters. Indications of thick and smeared barrel shocks were however observed in the computed flow-thermal fields. The modelled fluid was assumed to be a perfect gas with temperature dependent specific heats, thermal conductivity and viscosity coefficients, with constant Prandtl number of order unity. The radial spreads of the jets increase with increasing pressure ratio thus leading to enhanced interactions within reduced distances downstream of the nozzle exit. The jet core Mach number also increases, but moderately, with decreasing backpressure. It is concluded that within reasonable accuracy, continuum approach based calculations are able to capture most of the important phenomena involved in compressible, high-temperature, supersonic jet expansion processes which are essential in designing chambers relevant to the mentioned processes.

  17. DUHOCAMIS: a dual hollow cathode ion source for metal ion beams.

    PubMed

    Zhao, W J; Müller, M W O; Janik, J; Liu, K X; Ren, X T

    2008-02-01

    In this paper we describe a novel ion source named DUHOCAMIS for multiply charged metal ion beams. This ion source is derived from the hot cathode Penning ion gauge ion source (JINR, Dubna, 1957). A notable characteristic is the modified Penning geometry in the form of a hollow sputter electrode, coaxially positioned in a compact bottle-magnetic field along the central magnetic line of force. The interaction of the discharge geometry with the inhomogeneous but symmetrical magnetic field enables this device to be operated as hollow cathode discharge and Penning discharge as well. The main features of the ion source are the very high metal ion efficiency (up to 25%), good operational reproducibility, flexible and efficient operations for low charged as well as highly charged ions, compact setup, and easy maintenance. For light ions, e.g., up to titanium, well-collimated beams in the range of several tens of milliamperes of pulsed ion current (1 ms, 10/s) have been reliably performed in long time runs.

  18. Dual source CT (DSCT) imaging of obese patients: evaluation of CT number accuracy, uniformity, and noise

    NASA Astrophysics Data System (ADS)

    Walz-Flannigan, A.; Schmidt, B.,; Apel, A.; Eusemann, C.; Yu, L.; McCollough, C. H.

    2009-02-01

    Obese patients present challenges in obtaining sufficient x-ray exposure over reasonable time periods for acceptable CT image quality. To overcome this limitation, the exposure can be divided between two x-ray sources using a dualsource (DS) CT system. However, cross-scatter issues in DS CT may also compromise image quality. We evaluated a DS CT system optimized for imaging obese patients, comparing the CT number accuracy and uniformity to the same images obtained with a single-source (SS) acquisition. The imaging modes were compared using both solid cylindrical PMMA phantoms and a semi-anthropomorphic thorax phantom fitted with extension rings to simulate different size patients. Clinical protocols were used and CTDIvol and kVp were held constant between SS and DS modes. Results demonstrated good agreement in CT number between SS and DS modes in CT number, with the DS mode showing better axial uniformity for the largest phantoms.

  19. Food sources of macro-invertebrates in an important mangrove ecosystem of Vietnam determined by dual stable isotope signatures

    NASA Astrophysics Data System (ADS)

    Tue, Nguyen Tai; Hamaoka, Hideki; Sogabe, Atsushi; Quy, Tran Dang; Nhuan, Mai Trong; Omori, Koji

    2012-08-01

    Dual stable isotope signatures (δ13C and δ15N) were applied to determine the contribution of mangrove materials and other organic carbon sources to the invertebrate community in an ecologically important mangrove ecosystem of Vietnam. We have analyzed 181 specimens of 30 invertebrate species and found δ13C and δ15N ranging from - 14.5 to - 26.8‰ and from 1.3 to 12.1‰, respectively. From taxa measured for stable isotopes, polychaete, gastropods, bivalves, and grapsid crabs living in mangrove forest showed relative low δ13C values, while fiddler crabs inhabiting in the land-water ecotone showed the highest δ13C values. The δ13C showed that just a few mangrove inhabitants directly relied on the mangrove materials. The wide ranges of δ13C and δ15N signatures indicated that the invertebrates utilized heterogeneous diets, comprising benthic microalgae, marine phytoplankton, particulate organic matter, sediment organic matter, mangrove detritus, and meiofauna and rotten animal tissues as the supplemental nutrient food sources. Moreover, the significant correlation between δ13C values and body sizes of invertebrates showed that snails Littoraria melanostoma and Terebralia sulcata, bivalve Glauconome virens, and portunid crab Scylla serrata exhibited ontogenetic shifts in diets. The present study showed that adjacent habitats such as tidal flat and mangrove creeks seem to contribute an important microalgal food resource for invertebrates and highlighted the need for conservations of mangrove forests and the adjacent habitats.

  20. Active induction balance method for metal detector sensing head utilizing transmitter-bucking and dual current source

    NASA Astrophysics Data System (ADS)

    Ambruš, D.; Vasić, D.; Bilas, V.

    2013-06-01

    A central problem in a design of frequency domain electromagnetic induction sensors used in landmine detection is an effective suppression of a direct inductive coupling between the transmitter and the receiver coil (induction balance, IB). In sensing heads based on the transmitter-bucking configuration, IB is achieved by using two concentric transmitter coils with opposing exciter fields in order to create a central magnetic cavity for the receiver coil. This design has numerous advantages over other IB methods in terms of detection sensitivity, spatial resolution, sensor dimensions and suitability for model-based measurements. However, very careful design and precise sensing head geometry are required if a single excitation source is used for driving both transmitter coils. In this paper we analyze the IB sensitivity to small perturbations of geometrical properties of coils. We propose a sensor design with dual current source and active induction balance scheme which overcomes the limitations of geometry-based balancing and potentially provides more efficient compensation of soil effects.

  1. Evaluation of Wall Boundary Conditions for Impedance Eduction Using a Dual-Source Method

    NASA Technical Reports Server (NTRS)

    Watson, W. R.; Jones, M. G.

    2012-01-01

    The accuracy of the Ingard-Myers boundary condition and a recently proposed modified Ingard-Myers boundary condition is evaluated for use in impedance eduction under the assumption of uniform mean flow. The evaluation is performed at three centerline Mach numbers, using data acquired in a grazing flow impedance tube, using both upstream and downstream propagating sound sources, and on a database of test liners for which the expected behavior of the impedance spectra is known. The test liners are a hard-wall insert consisting of 12.6 mm thick aluminum, a linear liner without a facesheet consisting of a number of small diameter but long cylindrical channels embedded in a ceramic material, and two conventional nonlinear liners consisting of a perforated facesheet bonded to a honeycomb core. The study is restricted to a frequency range for which only plane waves are cut on in the hard-wall sections of the flow impedance tube. The metrics used to evaluate each boundary condition are 1) how well it educes the same impedance for upstream and downstream propagating sources, and 2) how well it predicts the expected behavior of the impedance spectra over the Mach number range. The primary conclusions of the study are that the same impedance is educed for upstream and downstream propagating sources except at the highest Mach number, that an effective impedance based on both the upstream and downstream measurements is more accurate than an impedance based on the upstream or downstream data alone, and that the Ingard-Myers boundary condition with an effective impedance produces results similar to that achieved with the modified Ingard-Myers boundary condition.

  2. Broadly tunable dual-wavelength light source for coherent anti-Stokes Raman scattering microscopy.

    PubMed

    Ganikhanov, Feruz; Carrasco, Silvia; Sunney Xie, X; Katz, Mordechai; Seitz, Wolfgang; Kopf, Daniel

    2006-05-01

    The signal and idler beams from a picosecond, synchronously pumped optical parametric oscillator (OPO) provide the two colors necessary for coherent anti-Stokes Raman scattering (CARS) microscopy. The OPO provides a continuously tunable frequency difference between the two beams over a broad range of Raman shifts (100-3700 cm(-1)) by varying the temperature of a single nonlinear crystal. The near-infrared output (900-1300 nm) allows for deep penetration into thick samples and reduced nonlinear photodamage. Applications of this light source to in vivo cell and ex vivo tissue imaging are demonstrated.

  3. Using dual isotopes to evaluate sources and transformations of nitrate in the West Lake watershed, eastern China.

    PubMed

    Jin, Zanfang; Qin, Xue; Chen, Lingxiao; Jin, Mantong; Li, Feili

    2015-01-01

    The West Lake is a World Heritage site in the West Lake watershed in eastern China. In this study, the hydrogeological and dual isotopic approaches were integrated to evaluate the seasonal and spatial variations of nitrate (NO3(-)) in the West Lake watershed, and to characterize NO3(-) sources and transformations. The results revealed that the geochemical facies of the water samples were dominated by Ca(2+)+Na(+)-HCO3(-)+SO4(2)(-) in the surface water and transfer water, Ca(2+)+Na(+)-HCO3(-) and Ca(2+)+Na(+)-SO4(2-) in the groundwater, which most likely reflect natural reactions and anthropogenic inputs. About 13% of the groundwater samples containing NO3(-) exceeded the World Health Organization (WHO) standard of 10 mg N L(-1). NO3(-) was the dominant form of total nitrogen (TN) and was the main surface water contaminant in the West Lake watershed. The δ(15)NNO3 and δ(18)ONO3 values indicated that the dominant NO3(-) sources in surface water were soil nitrogen (soil N) and chemical fertilizers, while the main NO3(-) sources in groundwater were soil N from the forest, chemical fertilizers and manure in the tea garden, domestic sewage from the small, old residential area in the forest as well as urban areas. The distribution of NO3(-) in groundwater was strongly influenced by land use. Results also suggest that there was significant nitrification in surface water and groundwater in the West Lake watershed, and that there were also denitrification processes in groundwater. The annual net fluxes of TN, NO3(-), and NH4(+) into the West Lake were 2.0×10(4), 4.0×10(3), and 1.31×10(4) kg as N, respectively. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Using dual isotopes to evaluate sources and transformations of nitrate in the West Lake watershed, eastern China

    NASA Astrophysics Data System (ADS)

    Jin, Zanfang; Qin, Xue; Chen, Lingxiao; Jin, Mantong; Li, Feili

    2015-06-01

    The West Lake is a World Heritage site in the West Lake watershed in eastern China. In this study, the hydrogeological and dual isotopic approaches were integrated to evaluate the seasonal and spatial variations of nitrate (NO3-) in the West Lake watershed, and to characterize NO3- sources and transformations. The results revealed that the geochemical facies of the water samples were dominated by Ca2 + + Na+-HCO3- + SO42- in the surface water and transfer water, Ca2 + + Na+-HCO3- and Ca2 + + Na+-SO42 - in the groundwater, which most likely reflect natural reactions and anthropogenic inputs. About 13% of the groundwater samples containing NO3- exceeded the World Health Organization (WHO) standard of 10 mg N L- 1. NO3- was the dominant form of total nitrogen (TN) and was the main surface water contaminant in the West Lake watershed. The δ15NNO3 and δ18ONO3 values indicated that the dominant NO3- sources in surface water were soil nitrogen (soil N) and chemical fertilizers, while the main NO3- sources in groundwater were soil N from the forest, chemical fertilizers and manure in the tea garden, domestic sewage from the small, old residential area in the forest as well as urban areas. The distribution of NO3- in groundwater was strongly influenced by land use. Results also suggest that there was significant nitrification in surface water and groundwater in the West Lake watershed, and that there were also denitrification processes in groundwater. The annual net fluxes of TN, NO3-, and NH4+ into the West Lake were 2.0 × 104, 4.0 × 103, and 1.31 × 104 kg as N, respectively.

  5. Systematic radiation dose optimization of abdominal dual-energy CT on a second-generation dual-source CT scanner: assessment of the accuracy of iodine uptake measurement and image quality in an in vitro and in vivo investigations.

    PubMed

    Schindera, Sebastian T; Zaehringer, Caroline; D'Errico, Luigia; Schwartz, Fides; Kekelidze, Maka; Szucs-Farkas, Zsolt; Benz, Matthias R

    2017-05-03

    To assess the accuracy of iodine quantification in a phantom study at different radiation dose levels with dual-energy dual-source CT and to evaluate image quality and radiation doses in patients undergoing a single-energy and two dual-energy abdominal CT protocols. In a phantom study, the accuracy of iodine quantification (4.5-23.5 mgI/mL) was evaluated using the manufacturer-recommended and three dose-optimized dual-energy protocols. In a patient study, 75 abdomino-pelvic CT examinations were acquired as follows: 25 CT scans with the manufacturer-recommended dual-energy protocol (protocol A); 25 CT scans with a dose-optimized dual-energy protocol (protocol B); and 25 CT scans with a single-energy CT protocol (protocol C). CTDIvol and objective noise were measured. Five readers scored each scan according to six subjective image quality parameters (noise, contrast, artifacts, visibility of small structures, sharpness, overall diagnostic confidence). In the phantom study, differences between the real and measured iodine concentrations ranged from -8.8% to 17.0% for the manufacturer-recommended protocol and from -1.6% to 20.5% for three dose-optimized protocols. In the patient study, the CTDIvol of protocol A, B, and C were 12.5 ± 1.9, 7.5 ± 1.2, and 6.5 ± 1.7 mGycm, respectively (p < 0.001), and the average image noise values were 6.6 ± 1.2, 7.8 ± 1.4, and 9.6 ± 2.2 HU, respectively (p < 0.001). No significant differences in the six subjective image quality parameters were observed between the dose-optimized dual-energy and the single-energy protocol. A dose reduction of 41% is feasible for the manufacturer-recommended, abdominal dual-energy CT protocol, as it maintained the accuracy of iodine measurements and subjective image quality compared to a single-energy protocol.

  6. Image Quality and Radiation Dose for Prospectively Triggered Coronary CT Angiography: 128-Slice Single-Source CT versus First-Generation 64-Slice Dual-Source CT

    NASA Astrophysics Data System (ADS)

    Gu, Jin; Shi, He-Shui; Han, Ping; Yu, Jie; Ma, Gui-Na; Wu, Sheng

    2016-10-01

    This study sought to compare the image quality and radiation dose of coronary computed tomography angiography (CCTA) from prospectively triggered 128-slice CT (128-MSCT) versus dual-source 64-slice CT (DSCT). The study was approved by the Medical Ethics Committee at Tongji Medical College of Huazhong University of Science and Technology. Eighty consecutive patients with stable heart rates lower than 70 bpm were enrolled. Forty patients were scanned with 128-MSCT, and the other 40 patients were scanned with DSCT. Two radiologists independently assessed the image quality in segments (diameter >1 mm) according to a three-point scale (1: excellent; 2: moderate; 3: insufficient). The CCTA radiation dose was calculated. Eighty patients with 526 segments in the 128-MSCT group and 544 segments in the DSCT group were evaluated. The image quality 1, 2 and 3 scores were 91.6%, 6.9% and 1.5%, respectively, for the 128-MSCT group and 97.6%, 1.7% and 0.7%, respectively, for the DSCT group, and there was a statistically significant inter-group difference (P ≤ 0.001). The effective doses were 3.0 mSv in the 128-MSCT group and 4.5 mSv in the DSCT group (P ≤ 0.001). Compared with DSCT, CCTA with prospectively triggered 128-MSCT had adequate image quality and a 33.3% lower radiation dose.

  7. Influence of energy density of different light sources on Knoop hardness of a dual-cured resin cement.

    PubMed

    Piva, Evandro; Correr-Sobrinho, Lourenço; Sinhoreti, Mario Alexandre Coelho; Consani, Simonides; Demarco, Flávio Fernando; Powers, John Michael

    2008-01-01

    The purpose of this study was to evaluate the Knoop hardness of a dual-cured resin-based luting cement irradiated with different light sources as well energy density through a ceramic sample. Three light-curing unit (LCUs) were tested: tungsten halogen light (HAL), light-emitting diode (LED) and xenon plasma-arc (PAC) lamp. Disc-shaped specimens were fabricated from a resin-based cement (Enforce). Three energy doses were used by modifying the irradiance (I) of each LCU and the irradiation time (T): 24 Jcm(-2) (I/2x2T), 24 Jcm(-2) (IxT) and 48 Jcm(-2) (Ix2T). Energy doses were applied through a 2.0-mm-thick ceramic sample (Duceram Plus). Three groups underwent direct irradiation over the resin cement with the different LCUs and a chemically-activated group served as a control. Thirteen groups were tested (n=10). Knoop hardness number (KHN) means were obtained from cross-sectional areas. Two-way ANOVA and the Holm-Sidak method were used for statistical comparisons of activation mode and energy doses (alpha=5%). Application of 48 J.cm(-2) energy dose through the ceramic using LED (50.5+/-2.8) and HAL (50.9+/-3.7) produced significantly higher KHN means (p<0.05) than the control (44.7+/-3.8). LED showed statistically similar performance to HAL. Only HAL showed a relationship between the increase of LCU energy dose and hardness increase.

  8. Dual kidneys from marginal adult donors as a source for cadaveric renal transplantation in the United States.

    PubMed

    Bunnapradist, Suphamai; Gritsch, H Albin; Peng, Alice; Jordan, Stanley C; Cho, Yong W

    2003-04-01

    The current organ shortage has led to the utilization of double kidney transplants from marginal adult donors, but outcomes data are limited. The United Network for Organ Sharing registry database was used to compare the outcomes of 403 dual adult kidney transplantations (DKT) and 11,033 single kidney transplantations (SKT) from 1997 to 2000. Graft and patient survival and the effect of multiple risk factors were evaluated. It was found that DKT patients were older, less sensitized, and received grafts from older, more mismatched donors with longer cold ischemia times. There was also a greater percentage of donors with a history of diabetes or hypertension and African-American recipients and donors in the DKT group. Graft survival was inferior in the DKT group, with a 7% lower graft survival rate at 1 yr. There was a higher incidence of primary nonfunction in the DKT group, although the incidence of delayed graft function, early rejection treatment, and graft thrombosis did not differ. Multivariate analysis was used to identify African-American recipient ethnicity and retransplant as risk factors for graft loss. Graft survival was comparable in DKT and SKT with donors over 55 yr of age. DKT resulted in inferior graft outcomes compared with SKT. When compared with SKT with donors over 55 yr of age, DKT resulted in similar graft outcomes. These otherwise discarded kidneys should be cautiously considered as a source of marginal donors.

  9. Detection of Special Nuclear Material from Delayed Neutron Emission Induced by a Dual-Particle Monoenergetic Source

    SciTech Connect

    Mayer, Michael F.; Nattress, J.; Jovanovic, I

    2016-06-30

    Detection of unique signatures of special nuclear materials is critical for their interdiction in a variety of nuclear security and nonproliferation scenarios. We report on the observation of delayed neutrons from fission of uranium induced in dual-particle active interrogation based on the 11B(d,n gamma)12C nuclear reaction. Majority of the fissions are attributed to fast fission induced by the incident quasi-monoenergetic neutrons. A Li-doped glass–polymer composite scintillation neutron detector, which displays excellent neutron/γ discrimination at low energies, was used in the measurements, along with a recoil-based liquid scintillation detector. Time- dependent buildup and decay of delayed neutron emission from 238U were measured between the interrogating beam pulses and after the interrogating beam was turned off, respectively. Characteristic buildup and decay time profiles were compared to the common parametrization into six delayed neutron groups, finding a good agreement between the measurement and nuclear data. This method is promising for detecting fissile and fissionable materials in cargo scanning applications and can be readily integrated with transmission radiography using low-energy nuclear reaction sources.

  10. Detection of special nuclear material from delayed neutron emission induced by a dual-particle monoenergetic source

    SciTech Connect

    Mayer, M.; Nattress, J.; Jovanovic, I.

    2016-06-27

    Detection of unique signatures of special nuclear materials is critical for their interdiction in a variety of nuclear security and nonproliferation scenarios. We report on the observation of delayed neutrons from fission of uranium induced in dual-particle active interrogation based on the {sup 11}B(d,n γ){sup 12}C nuclear reaction. Majority of the fissions are attributed to fast fission induced by the incident quasi-monoenergetic neutrons. A Li-doped glass–polymer composite scintillation neutron detector, which displays excellent neutron/γ discrimination at low energies, was used in the measurements, along with a recoil-based liquid scintillation detector. Time-dependent buildup and decay of delayed neutron emission from {sup 238}U were measured between the interrogating beam pulses and after the interrogating beam was turned off, respectively. Characteristic buildup and decay time profiles were compared to the common parametrization into six delayed neutron groups, finding a good agreement between the measurement and nuclear data. This method is promising for detecting fissile and fissionable materials in cargo scanning applications and can be readily integrated with transmission radiography using low-energy nuclear reaction sources.

  11. Tetralogy of Fallot Cardiac Function Evaluation and Intelligent Diagnosis Based on Dual-Source Computed Tomography Cardiac Images.

    PubMed

    Cai, Ken; Rongqian, Yang; Li, Lihua; Xie, Zi; Ou, Shanxing; Chen, Yuke; Dou, Jianhong

    2016-05-01

    Tetralogy of Fallot (TOF) is the most common complex congenital heart disease (CHD) of the cyanotic type. Studies on ventricular functions have received an increasing amount of attention as the development of diagnosis and treatment technology for CHD continues to advance. Reasonable options for imaging examination and accurate assessment of preoperative and postoperative left ventricular functions of TOF patients are important in improving the cure rate of TOF radical operation, therapeutic evaluation, and judgment prognosis. Therefore, with the aid of dual-source computed tomography (DSCT), cardiac images with high temporal resolution and high definition, we measured the left ventricular time-volume curve using image data and calculating the left ventricular function parameters to conduct the preliminary evaluation on TOF patients. To comprehensively evaluate the cardiac function, the segmental ventricular wall function parameters were measured, and the measurement results were mapped to a bull's eye diagram to realize the standardization of segmental ventricular wall function evaluation. Finally, we introduced a new clustering method based on auto-regression model parameters and combined this method with Euclidean distance measurements to establish an intelligent diagnosis of TOF. The results of this experiment show that the TOF evaluation and the intelligent diagnostic methods proposed in this article are feasible. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  12. Efficacy of a dynamic collimator for overranging dose reduction in a second- and third-generation dual source CT scanner.

    PubMed

    Booij, Ronald; Dijkshoorn, Marcel L; van Straten, Marcel

    2017-09-01

    The purpose of this study was to assess the efficacy of the renewed dynamic collimator in a third-generation dual source CT (DSCT) scanner and to determine the improvements over the second-generation scanner. Collimator efficacy is defined as the percentage overranging dose in terms of dose-length product (DLP) that is blocked by the dynamic collimator relative to the total overranging dose in case of a static collimator. Efficacy was assessed at various pitch values and different scan lengths. The number of additional rotations due to overranging and effective scan length were calculated on the basis of reported scanning parameters. On the basis of these values, the efficacy of the collimator was calculated. The second-generation scanner showed decreased performance of the dynamic collimator at increasing pitch. Efficacy dropped to 10% at the highest pitch. For the third-generation scanner the efficacy remained above 50% at higher pitch. Noise was for some pitch values slightly higher at the edge of the imaged volume, indicating a reduced scan range to reduce the overranging dose. The improved dynamic collimator in the third-generation scanner blocks the overranging dose for more than 50% and is more capable of shielding radiation dose, especially in high pitch scan modes. • Overranging dose is to a large extent blocked by the dynamic collimator • Efficacy is strongly improved within the third-generation DSCT scanner • Reducing the number of additional rotations can reduce overranging with increased noise.

  13. Detection of significant coronary artery stenosis with cardiac dual-source computed tomography angiography in heart transplant recipients.

    PubMed

    von Ziegler, Franz; Rümmler, Janine; Kaczmarek, Ingo; Greif, Martin; Schenzle, Jan; Helbig, Susanne; Becker, Christoph; Meiser, Bruno; Becker, Alexander

    2012-10-01

    Present study evaluates clinical feasibility of cardiac dual-source computed tomography angiography (DSCTA) to detect significant coronary stenosis because of chronic allograft vasculopathy (CAV) after heart transplantation (HTX). An overall of 51 consecutive heart transplant recipients (43 men, 8 women, mean age: 52.3 ± 13.6 years) underwent DSCTA 1 ± 2 days before annual routine invasive coronary angiography (ICA). Three patients were excluded from further analysis. Total 714/717 (99.6%) segments in remaining 48 patients were depicted in diagnostic image quality by DSCTA with three vessel segments in two patients being additionally excluded because of motion artefacts. On a segment-based analysis, sensitivity, specificity, and diagnostic accuracy (DA) for detection of significant stenosis were calculated as 100%, 98.9% and 98.9% respectively. On a patient-based evaluation, sensitivity, specificity and DA were 100%, 86.0% and 93.0% respectively for remaining 46 patients. Negative predictive value (NPV) was 100%. DSCTA enables diagnosis and especially the exclusion of significant coronary artery stenosis in patients after HTX with a high NPV. The low rate of excluded vessel segments compared with former studies indicates improvement in image acquisition and robustness of latest scanner technology and thus may make subsequent annual invasive coronary angiography unnecessary. © 2012 The Authors. Transplant International © 2012 European Society for Organ Transplantation.

  14. Detection of special nuclear material from delayed neutron emission induced by a dual-particle monoenergetic source

    NASA Astrophysics Data System (ADS)

    Mayer, M.; Nattress, J.; Jovanovic, I.

    2016-06-01

    Detection of unique signatures of special nuclear materials is critical for their interdiction in a variety of nuclear security and nonproliferation scenarios. We report on the observation of delayed neutrons from fission of uranium induced in dual-particle active interrogation based on the 11B(d,n γ)12C nuclear reaction. Majority of the fissions are attributed to fast fission induced by the incident quasi-monoenergetic neutrons. A Li-doped glass-polymer composite scintillation neutron detector, which displays excellent neutron/γ discrimination at low energies, was used in the measurements, along with a recoil-based liquid scintillation detector. Time-dependent buildup and decay of delayed neutron emission from 238U were measured between the interrogating beam pulses and after the interrogating beam was turned off, respectively. Characteristic buildup and decay time profiles were compared to the common parametrization into six delayed neutron groups, finding a good agreement between the measurement and nuclear data. This method is promising for detecting fissile and fissionable materials in cargo scanning applications and can be readily integrated with transmission radiography using low-energy nuclear reaction sources.

  15. A dual-energy medical instrument for measurement of x-ray source voltage and dose rate

    NASA Astrophysics Data System (ADS)

    Ryzhikov, V. D.; Naydenov, S. V.; Volkov, V. G.; Opolonin, O. D.; Makhota, S.; Pochet, T.; Smith, C. F.

    2016-03-01

    An original dual-energy detector and medical instrument have been developed to measure the output voltages and dose rates of X-ray sources. Theoretical and experimental studies were carried out to characterize the parameters of a new scintillator-photodiode sandwich-detector based on specially-prepared zinc selenide crystals in which the low-energy detector (LED) works both as the detector of the low-energy radiation and as an absorption filter allowing the highenergy fraction of the radiation to pass through to the high-energy detector (HED). The use of the LED as a low-energy filter in combination with a separate HED opens broad possibilities for such sandwich structures. In particular, it becomes possible to analyze and process the sum, difference and ratio of signals coming from these detectors, ensuring a broad (up to 106) measurement range of X-ray intensity from the source and a leveling of the energy dependence. We have chosen an optimum design of the detector and the geometry of the component LED and HED parts that allow energy-dependence leveling to within specified limits. The deviation in energy dependence of the detector does not exceed about 5% in the energy range from 30 to 120 keV. The developed detector and instrument allow contactless measurement of the anode voltage of an X-ray emitter from 40 to 140 kV with an error no greater than 3%. The dose rate measurement range is from 1 to 200 R/min. An original medical instrument has passed clinical testing and was recommended for use in medical institutions for X-ray diagnostics.

  16. Initial Experience of the Application of Third-generation Dual-source CT Scanner in High-pitch Angiography of Aorta.

    PubMed

    Liang, Jixiang; Kong, Lingyan; Jin, Zhengyu; Wang, Yun; Xue, Huadan; Wang, Yining; Zhang, Daming; Chen, Jin

    2017-02-20

    Objective To evaluate the value of third-generation dual-source CT scanner in application of high-pitch aorta CT angiography(CTA). Methods Totally 59 patients clinically indicated for whole aorta angiography were divided into 2 groups using a simple random method:in group 1 there were 28 patients who underwent the examination on a third-generation dual-source CT device,with a collimation of 2×192×0.6 mm and a rotation time of 0.25 s;in group 2 there were 31 patients who underwent the examination on a second generation dual-source CT device,with a collimation of 2×128×0.6 mm and a rotation time of 0.28 s. Both groups were given the examination operated in dual-source high-pitch ECG-gating mode with a pitch of 3.0,a tube voltage of 100 kV,and automated tube current modulation using a reference tube current of 288 mA. A contrast material bolus of 45 ml with a flow of 4.5 ml/s followed by a 50 ml saline chaser in 5.0 ml/s was used. CTA scan was automatically started using a bolus tracking technique at the level of the original part of aorta after a trigger threshold of 100 HU was reached. The start delay was set to 6 s in both groups. Effective dose(ED),signal to noise ratio (SNR),contrast to noise ratio (CNR),and subjective diagnostic quality of both groups were evaluated. Results The mean ED were 19.44% lower (t=-3.989,P=0.000) in group 1 [(3.15±0.86)mSv] than in group 2 [(3.91±0.60)mSv]. These two groups showed no significant differences in SNR or CNR (all P >0.05). The subjective diagnostic quality values also showed no significant difference between two groups [(1.39±0.50)scores vs. (1.45±0.51)scores;W=814.5,P=0.651].Conclusion Compared with the second-generation dual-source CT scanner,the third-generation dual-source CT scanner in whole aorta CTA can remarkably reduce the radiation dose without affecting image quality.

  17. First Clinical Evaluation of High-Pitch Dual-Source Computed Tomographic Angiography Comparing Automated Tube Potential Selection With Automated Tube Current Modulation.

    PubMed

    Beeres, Martin; Williams, Kimberly; Bauer, Ralf W; Scholtz, Jan; Kaup, Moritz; Gruber-Rouh, Tatjana; Lee, Clara; Wichmann, Julian L; Frellesen, Claudia; Nour-Eldin, Nour-Eldin A; Vogl, Thomas J; Kerl, Josef Matthias; Bodelle, Boris

    2015-01-01

    To investigate and compare the use of automated tube potential selection (ATPS) with automated tube current modulation (ATCM) in high-pitch dual-source computed tomographic angiography (CTA) for imaging the whole aorta without electrocardiogram synchronization. Two groups of 60 patients underwent CTA on a dual-source computed tomographic device in high-pitch mode: ATCM (with 100-kV fixed tube potential) was used in group 1 and ATPS (with the same image quality options) in group 2. For the evaluation of radiation exposure, CT dose index and dose-length product were analyzed. Contrast and image quality were assessed by 2 independent observers. The ATPS group received a higher radiation dose than the ATCM group (P < 0.001) because in 80% of patients, the software switched to use of a 120-kV tube potential. In all cases, images of the aorta were of sufficient quality. High-pitch dual-source CTA of the aorta using ATPS is feasible in clinical routine, but is associated with higher radiation exposure than the ATCM protocol. This finding contradicts previously evaluations of ATPS based on single-source techniques.

  18. Coronary calcium screening with dual-source CT: reliability of ungated, high-pitch chest CT in comparison with dedicated calcium-scoring CT.

    PubMed

    Hutt, Antoine; Duhamel, Alain; Deken, Valérie; Faivre, Jean-Baptiste; Molinari, Francesco; Remy, Jacques; Remy-Jardin, Martine

    2016-06-01

    To investigate the reliability of ungated, high-pitch dual-source CT for coronary artery calcium (CAC) screening. One hundred and eighty-five smokers underwent a dual-source CT examination with acquisition of two sets of images during the same session: (a) ungated, high-pitch and high-temporal resolution acquisition over the entire thorax (i.e., chest CT); (b) prospectively ECG-triggered acquisition over the cardiac cavities (i.e., cardiac CT). Sensitivity and specificity of chest CT for detecting positive CAC scores were 96.4 % and 100 %, respectively. There was excellent inter-technique agreement for determining the quantitative CAC score (ICC = 0.986). The mean difference between the two techniques was 11.27, representing 1.81 % of the average of the two techniques. The inter-technique agreement for categorizing patients into the four ranks of severity was excellent (weighted kappa = 0.95; 95 % CI 0.93-0.98). The inter-technique differences for quantitative CAC scores did not correlate with BMI (r = 0.05, p = 0.575) or heart rate (r = -0.06, p = 0.95); 87.2 % of them were explained by differences at the level of the right coronary artery (RCA: 0.8718; LAD: 0.1008; LCx: 0.0139; LM: 0.0136). Ungated, high-pitch dual-source CT is a reliable imaging mode for CAC screening in the conditions of routine chest CT examinations. • CAC is an independent risk factor for major cardiac events. • ECG-gated techniques are the reference standard for calcium scoring. • Great interest is directed toward calcium scoring on non-gated chest CT examinations. • Reliable calcium scoring can be obtained with dual-source CT in a high-pitch mode.

  19. Evaluation of high-pitch dual-source CT angiography for evaluation of coronary and carotid-cerebrovascular arteries.

    PubMed

    Sun, Kai; Li, Kuncheng; Han, Ruijuan; Li, Wenhuan; Chen, Nan; Yang, Qi; Du, Xiangying; Wang, Chen; Liu, Guorong; Li, Yuechun; Zhou, Maorong; Li, Ligang; Heidrun, Endt

    2015-03-01

    To explore the feasibility and diagnostic accuracy of a combined one-step high-pitch dual-source computed tomography angiography (CTA) technique for evaluation of coronary and carotid-cerebrovascular arteries. 85 symptomatic patients suspected of coronary artery and cerebrovascular disease referred for simultaneous coronary and carotid-cerebrovascular CTA were included. Additional invasive angiography of the coronary and cerebral arteries was performed within 30 days in 23 and 13 patients, respectively. The objective parameters of image quality, the mean CT attenuations, image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were evaluated. The subjective image quality of vessels was also assessed by 2 independent radiologists blinded to the patients' medical history and scan protocols. The diagnostic performance of CTA including sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) for the detection or exclusion of significant artery stenosis was calculated using the chi-squared test of contingency and correlated with the results of invasive angiography representing the standard of reference. Image quality was rated excellent (score 1) in 95.3% (1074/1127), good (score 2) in 3.3% (37/1127), adequate (score 3) in 1.0% (11/1127), and non-diagnostic (score 4) in 0.4% (5/1127) of coronary segments. Image quality of carotid and cerebral vessels was rated mostly excellent (score 1, 95.12% [78/82]; score 2, 3.66% [3/82]; score 3, 1.22% [1/82]). The sensitivity, specificity, PPV and NPV for the detection of coronary stenosis were 92.2% (81.1-97.7%), 95.2% (91.7-97.5%), 79.6% (67.1-89.1%) and 98.3% (95.8-99.5%), respectively. For the detection of carotid and cerebral artery stenosis, CTA demonstrated a sensitivity of 92.8% (80.5-98.4%), a specificity of 93.5% (88.3-96.8%), a PPV of 79.6% (65.6-89.7%) and a NPV of 97.9% (94.1-99.5%). The effective radiation dose was 1.42±0.44mSv (range, 0.88-3.35mSv). Dual-source

  20. Effect of age and plaque morphology on diagnostic accuracy of dual source multidetector computed tomography coronary angiography

    PubMed Central

    Sunman, Hamza; Aytemir, Kudret; Yorgun, Hikmet; Canpolat, Uğur; Taher, Ali; Demiri, Edis; Hazırolan, Tuncay; Şahiner, Levent; Kaya, Ergün B.; Kabakçı, Giray; Tokgözoğlu, Lale; Oto, Ali

    2014-01-01

    Background Multidetector computed tomography (MDCT) coronary angiography represents one of the most exciting technological revolutions in cardiac imaging and it has been increasingly used in the diagnosis of coronary artery disease. The purpose of this study is to investigate the effect of age and coronary plaque calcification on diagnostic accuracy of MDCT. Methods The patients were examined by using dual-source MDCT and conventional coronary angiography. MDCT results were analyzed with regard to the severity (> 50% stenosis) and morphology (non-calcified, mixed, or calcified) of coronary atherosclerotic plaques evaluated in a 16-segment model. Results In total, 181 patients (94 men and 87 women) with 2,687 coronary artery segments were examined with MDCT. Ninety three patients were older than 65 years of age (group A, 42 men) and 88 were younger (group B, 52 men). Two-hundred nine coronary artery segments (7.2%) were excluded because of small distal coronary vessel segments and/or motion artifacts. The overall number of segments with non-diagnostic image quality was similar in both groups of patients. Of the 2,687 evaluated segments, 157 (5.8%) were significantly diseased, and 144 of them were correctly detected by MDCT. Diagnostic evaluation showed that the sensitivity, positive predictive value, specificity, and negative predictive value were 89.5%, 62.5%, 96.0%, and 99.2%, respectively in group A, and 95.2%, 64.8%, 97.5%, and 99.8% in group B, respectively. In addition, detailed segment-based analyses in coronary segments with non-calcified, mixed and calcified plaques in both groups were similar diagnostic accuracy. Conclusions Very high diagnostic accuracy observed in this study suggests that MDCT coronary angiography could be a suitable diagnostic tool for not only younger patients but also for older patients. PMID:25009559

  1. Performance of dual-source CT with high pitch spiral mode for coronary stent patency compared with invasive coronary angiography.

    PubMed

    Yang, Xia; Yu, Qiang; Dong, Wei; Fu, Zhen-Hong; Yang, Jun-Jue; Guo, Jun; Chen, Yun-Dai

    2016-10-01

    To investigate the performance of dual-source computed tomography (DSCT) using high-pitch spiral (HPS) mode for coronary stents patency. We conducted a prospective study on 120 patients with 260 previous stents implanted due to recurred suspicious symptoms of angina scheduled for invasive coronary angiography (ICA), while DSCT were conducted using HPS mode. There was no significant impact of age, body mass index or heat rate (HR) on image quality (P > 0.05), while HR variability had a slight impact on that (P < 0.05). Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) of DSCT in detection of in-stent restenosis (ISR) based per-patient were 92.3%, 96.7%, 88.9%, and 97.8%, respectively. And those based per-stent were 87%, 96.8%, 83.3%, and 97.7% with un-assessment stents, 97.4%, 99.5%, 97.4%, and 99.5% without un-assessment stents. There was significant difference on sensitivity, specificity, PPV and NPV between diameter ≥ 3.0 mm group (93.3%, 97.9%, 87.5%, and 98.9%) and diameter < 3.0 mm group (80%, 93.3%, 80.0%, and 93.3%) (P < 0.05), and that between stent number ≥ 3 group (82.3%, 77.8%, 66.7%, and 60%) with < 3 group (97.3%, 80%, 96.5%, and 75%). The effective dose of DSCT (1.4 ± 0.5 mSv) is significantly less than that by invasive coronary angiography [4.0 ± 0.8 mSv (P < 0.01)]. DSCT using HPS mode provides good diagnostic performance on stent patency with lower effective dose in patients with HR < 65 beats/min.

  2. Imaging of the Coronary Venous System: Validation of Three-Dimensional Rotational Venous Angiography Against Dual-Source Computed Tomography

    SciTech Connect

    Knackstedt, Christian; Muehlenbruch, Georg; Mischke, Karl; Bruners, Philipp; Schimpf, Thomas; Frechen, Dirk; Schummers, Georg; Mahnken, Andreas H.; Guenther, Rolf W.; Kelm, Malte; Schauerte, Patrick

    2008-11-15

    Information on the anatomy of the cardiac venous system (CVS) is increasingly important for cardiac resynchronization therapy or percutaneous transvenous mitral valve annuloplasty. Three-dimensional (3D) imaging can further improve the understanding of the relationship of cardiac structures. This study was performed to validate the accuracy of rotational coronary sinus angiography (CSA) displaying the 3D anatomy of the CVS compared to ECG-gated, contrast-enhanced, cardiac dual-source computed tomography (DSCT). Five domestic pigs (60 kg) underwent DSCT using a standardized examination protocol. Using a standard C-arm for fluoroscopy, a rotational CSA was obtained and 3D-image reconstructions performed. Side branches were identified using both methods and enumerated. Vessel visibility was estimated for each side branch and great cardiac vein/anterior interventricular vein. Also, vessel diameters were measured at distinct landmarks, i.e., side branching. The amount of contrast medium was determined and the effective radiation exposure of both methods was calculated. There was no significant difference regarding the vessel diameter of the great cardiac vein/anterior interventricular vein or its side branches. Also, estimation of vessel visibility was not different between the two imaging modalities. Estimated radiation exposure and amount of contrast medium were lower for rotational CSA. In conclusion, a 3D reconstruction of rotational CSA images is possible. All parts of the CVS are well depicted, allowing a 3D overview of the CVS anatomy. On-site 3D visualization might improve decision making during cardiac interventions. In contrast to DSCT, rotational CSA does not demonstrate the anatomy of the mitral annulus or the course of the left circumflex artery.

  3. Ultra-high-resolution dual-source CT for forensic dental visualization-discrimination of ceramic and composite fillings.

    PubMed

    Jackowski, C; Wyss, M; Persson, A; Classens, M; Thali, M J; Lussi, A

    2008-07-01

    Dental identification is the most valuable method to identify human remains in single cases with major postmortem alterations as well as in mass casualties because of its practicability and demanding reliability. Computed tomography (CT) has been investigated as a supportive tool for forensic identification and has proven to be valuable. It can also scan the dentition of a deceased within minutes. In the present study, we investigated currently used restorative materials using ultra-high-resolution dual-source CT and the extended CT scale for the purpose of a color-encoded, in scale, and artifact-free visualization in 3D volume rendering. In 122 human molars, 220 cavities with 2-, 3-, 4- and 5-mm diameter were prepared. With presently used filling materials (different composites, temporary filling materials, ceramic, and liner), these cavities were restored in six teeth for each material and cavity size (exception amalgam n = 1). The teeth were CT scanned and images reconstructed using an extended CT scale. Filling materials were analyzed in terms of resulting Hounsfield units (HU) and filling size representation within the images. Varying restorative materials showed distinctively differing radiopacities allowing for CT-data-based discrimination. Particularly, ceramic and composite fillings could be differentiated. The HU values were used to generate an updated volume-rendering preset for postmortem extended CT scale data of the dentition to easily visualize the position of restorations, the shape (in scale), and the material used which is color encoded in 3D. The results provide the scientific background for the application of 3D volume rendering to visualize the human dentition for forensic identification purposes.

  4. The superior aspect of the perirenal space: could it be depicted by dual-source CT in vivo in adults

    PubMed Central

    Qi, R; Zhou, X P; Li, Z L

    2015-01-01

    Objective: This study aims to observe whether the renal fascias could be effectively shown by dual-source CT (DSCT) and to explore the superior communication of the perirenal space (PS) in vivo in adults. Methods: 275 cases were included in the normal group and 124 cases in the acute pancreatitis group in this study; all images obtained by DSCT were observed; the superior adherence of the renal fascias and the pattern of superior communication of the PS were judged; and the consistency between the two groups was compared. Results: The superior adherence of the renal fascias was reliably displayed in 57.8% of the normal group and 69.4% of the acute pancreatitis group, the anterior renal fascia (ARF) did not fuse with the posterior renal fascia superiorly. The left ARF fused with the posterior parietal peritoneum in 57.9% of the normal group and 45.3% of the pancreatitis group, where the left PS communicated with the subdiaphragmatic retroperitoneal space (SDRS). The left ARF fused with the peritoneum laterally and simultaneously with the inferior phrenic fascia medially in 42.1% and 54.7% of each group, respectively, where the left PS was open towards the SDRS laterally but sealed off from the SDRS medially. The right ARF fused with the peritoneum in all cases; and the right PS was open towards the bare area of the liver. Conclusion: To some extent, DSCT can display renal fascia and its superior adherence and reflect the superior communication of the PS. Advances in knowledge: This study was conducted in vivo in adults by high-resolution DSCT, and more samples could be provided. PMID:25411900

  5. Dual-Source CT Angiography of Peripheral Arterial Stents: In Vitro Evaluation of 22 Different Stent Types

    PubMed Central

    Köhler, Michael; Burg, Matthias C.; Bunck, Alexander C.; Heindel, Walter; Seifarth, Harald; Maintz, David

    2011-01-01

    Purpose. To test different peripheral arterial stents using four image reconstruction approaches with respect to lumen visualization, lumen attenuation and image noise in dual-source multidetector row CT (DSCT) in vitro. Methods and Materials. 22 stents (nitinol, steel, cobalt-alloy, tantalum, platinum alloy) were examined in a vessel phantom. All stents were imaged in axial orientation with standard parameters. Image reconstructions were obtained with four different convolution kernels. To evaluate visualization characteristics of the stent, the lumen diameter, intraluminal density and noise were measured. Results. The mean percentage of the visible stent lumen diameter from the nominal stent diameter was 74.5% ± 5.7 for the medium-sharp kernel, 72.8% ± 6.4 for the medium, 70.8% ± 6.4 for the medium-smooth and 67.6% ± 6.6 for the smooth kernel. Mean values of lumen attenuation were 299.7HU ± 127 (medium-sharp), 273.9HU ± 68 (medium), 270.7HU ± 53 (medium-smooth) and 265.8HU ± 43. Mean image noise was: 54.6 ± 6.3, 20.5 ± 1.7, 16.3 ± 1.7, 14.0 ± 2 respectively. Conclusion. Visible stent lumen diameter varies depending on stent type and scan parameters. Lumen diameter visibility increases with the sharpness of the reconstruction kernel. Smoother kernels provide more realistic density measurements inside the stent lumen and less image noise. PMID:22091369

  6. Optimal reconstruction interval in dual source CT coronary angiography: a single-center experience in 285 patients.

    PubMed

    Akgöz, Ayça; Akata, Deniz; Hazırolan, Tuncay; Karçaaltıncaba, Muşturay

    2014-01-01

    We aimed to evaluate the visibility of coronary arteries and bypass-grafts in patients who underwent dual source computed tomography (DSCT) angiography without heart rate (HR) control and to determine optimal intervals for image reconstruction. A total of 285 consecutive cases who underwent coronary (n=255) and bypass-graft (n=30) DSCT angiography at our institution were identified retrospectively. Patients with atrial fibrillation were excluded. Ten datasets in 10% increments were reconstructed in all patients. On each dataset, the visibility of coronary arteries was evaluated using the 15-segment American Heart Association classification by two radiologists in consensus. Mean HR was 76±16.3 bpm, (range, 46-127 bpm). All coronary segments could be visualized in 277 patients (97.19%). On a segment-basis, 4265 of 4275 (99.77%) coronary artery segments were visible. All segments of 56 bypass-grafts in 30 patients were visible (100%). Total mean segment visibility scores of all coronary arteries were highest at 70%, 40%, and 30% intervals for all HRs. The optimal reconstruction intervals to visualize the segments of all three coronary arteries in descending order were 70%, 60%, 80%, and 30% intervals in patients with a mean HR <70 bpm; 40%, 70%, and 30% intervals in patients with a mean HR 70-100 bpm; and 40%, 50%, and 30% in patients with a mean HR >100 bpm. Without beta-blocker administration, DSCT coronary angiography offers excellent visibility of vascular segments using both end-systolic and mid-late diastolic reconstructions at HRs up to 100 bpm, and only end-systolic reconstructions at HRs over 100 bpm.

  7. Optimal reconstruction interval in dual source CT coronary angiography: a single-center experience in 285 patients

    PubMed Central

    Akgöz, Ayça; Akata, Deniz; Hazırolan, Tuncay; Karçaaltıncaba, Muşturay

    2014-01-01

    PURPOSE We aimed to evaluate the visibility of coronary arteries and bypass-grafts in patients who underwent dual source computed tomography (DSCT) angiography without heart rate (HR) control and to determine optimal intervals for image reconstruction. MATERIALS AND METHODS A total of 285 consecutive cases who underwent coronary (n=255) and bypass-graft (n=30) DSCT angiography at our institution were identified retrospectively. Patients with atrial fibrillation were excluded. Ten datasets in 10% increments were reconstructed in all patients. On each dataset, the visibility of coronary arteries was evaluated using the 15-segment American Heart Association classification by two radiologists in consensus. RESULTS Mean HR was 76±16.3 bpm, (range, 46–127 bpm). All coronary segments could be visualized in 277 patients (97.19%). On a segment-basis, 4265 of 4275 (99.77%) coronary artery segments were visible. All segments of 56 bypass-grafts in 30 patients were visible (100%). Total mean segment visibility scores of all coronary arteries were highest at 70%, 40%, and 30% intervals for all HRs. The optimal reconstruction intervals to visualize the segments of all three coronary arteries in descending order were 70%, 60%, 80%, and 30% intervals in patients with a mean HR <70 bpm; 40%, 70%, and 30% intervals in patients with a mean HR 70–100 bpm; and 40%, 50%, and 30% in patients with a mean HR >100 bpm. CONCLUSION Without beta-blocker administration, DSCT coronary angiography offers excellent visibility of vascular segments using both end-systolic and mid-late diastolic reconstructions at HRs up to 100 bpm, and only end-systolic reconstructions at HRs over 100 bpm. PMID:24834490

  8. Performance of dual-source CT with high pitch spiral mode for coronary stent patency compared with invasive coronary angiography

    PubMed Central

    Yang, Xia; Yu, Qiang; Dong, Wei; Fu, Zhen-Hong; Yang, Jun-Jue; Guo, Jun; Chen, Yun-Dai

    2016-01-01

    Objective To investigate the performance of dual-source computed tomography (DSCT) using high-pitch spiral (HPS) mode for coronary stents patency. Methods We conducted a prospective study on 120 patients with 260 previous stents implanted due to recurred suspicious symptoms of angina scheduled for invasive coronary angiography (ICA), while DSCT were conducted using HPS mode. Results There was no significant impact of age, body mass index or heat rate (HR) on image quality (P > 0.05), while HR variability had a slight impact on that (P < 0.05). Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) of DSCT in detection of in-stent restenosis (ISR) based per-patient were 92.3%, 96.7%, 88.9%, and 97.8%, respectively. And those based per-stent were 87%, 96.8%, 83.3%, and 97.7% with un-assessment stents, 97.4%, 99.5%, 97.4%, and 99.5% without un-assessment stents. There was significant difference on sensitivity, specificity, PPV and NPV between diameter ≥ 3.0 mm group (93.3%, 97.9%, 87.5%, and 98.9%) and diameter < 3.0 mm group (80%, 93.3%, 80.0%, and 93.3%) (P < 0.05), and that between stent number ≥ 3 group (82.3%, 77.8%, 66.7%, and 60%) with < 3 group (97.3%, 80%, 96.5%, and 75%). The effective dose of DSCT (1.4 ± 0.5 mSv) is significantly less than that by invasive coronary angiography [4.0 ± 0.8 mSv (P < 0.01)]. Conclusion DSCT using HPS mode provides good diagnostic performance on stent patency with lower effective dose in patients with HR < 65 beats/min. PMID:27928222

  9. Coronary artery calcium scoring using a reduced tube voltage and radiation dose protocol with dual-source computed tomography.

    PubMed

    Nakazato, Ryo; Dey, Damini; Gutstein, Ariel; Le Meunier, Ludovic; Cheng, Victor Y; Pimentel, Raymond; Paz, William; Hayes, Sean W; Thomson, Louise E J; Friedman, John D; Berman, Daniel S

    2009-01-01

    Technical advances to minimize radiation exposure because of imaging are in accord with the "as low as reasonably achievable" principle. We aimed to determine whether coronary calcium scoring (CCS) by multidetector CT at a tube voltage of 100 kVp yields comparable results to the standard 120-kVp protocol while reducing radiation dose. Sixty consecutive outpatients were scanned with a dual-source CT scanner with both the120- and 100-kVp protocols. The calcium threshold was 130 Hounsfield units (HUs) for 120 kVp and 147 HU for 100 kVp, as determined from phantom data. All 100-kVp scans were scored by an experienced reader blinded to 120-kVp data. Image quality was comparable for 100- and 120- kVp scans. Mean Agatston scores for 100 and 120 kVp were 189 +/- 484 and 189 +/- 498 (P = 0.92), with perfect correlation (r = 1.0; P < 0.0001; 95% limits of agreement, -36 to 37; bias, 0.6). Mean coronary calcium volume scores for 100 and 120 kVp were 143 +/- 370 mm(3) and 149 +/- 392 mm(3) (P = 0.26), with perfect correlation (r = 1.0; P < 0.0001; 95% limits of agreement, -35 to 32 mm(3); bias, -1.4 mm(3)). The mean absolute difference for Agatston scores between the protocols was 16.9, with excellent agreement (kappa = 0.95; P < 0.0001). Mean effective radiation dose for the 100-kVp protocol was significantly lower (1.17 mSv versus 1.70 mSv; P < 0.0001). A reduced tube current protocol using 100 kVp gives equivalent CCS results at reduced radiation exposure compared with a standard protocol at 120 kVp. Copyright (c) 2009. Published by Elsevier Inc.

  10. ECG-gated Versus Non-ECG-gated High-pitch Dual-source CT for Whole Body CT Angiography (CTA).

    PubMed

    Beeres, Martin; Wichmann, Julian L; Frellesen, Claudia; Bucher, Andreas M; Albrecht, Moritz; Scholtz, Jan-Erik; Nour-Eldin, Nour-Eldin A; Gruber-Rouh, Tatjana; Lee, Clara; Vogl, Thomas J; Lehnert, Thomas

    2016-02-01

    To investigate motion artifacts, image quality, and practical differences in electrocardiographic (ECG)-gated versus non-ECG-gated high-pitch dual-source computed tomography angiography (CTA) of the whole aorta. Two groups, each including 40 patients, underwent either ECG-gated or non-ECG-gated high-pitch dual-source CTA of the whole aorta. The aortic annulus, aortic valve, coronary ostia, and the presence of motion artifacts of the thoracic aorta as well as vascular contrast down to the femoral arteries were independently assessed by two readers. Additional objective parameters including image noise and signal-to-noise ratio were analyzed. Subjective and objective scoring revealed no presence of motional artifacts regardless of whether the ECG-gated or the non-ECG-gated protocol was used (P > 0.1). Image acquisition parameters (examination length, examination duration, radiation dose) were comparable between the two groups without significant differences. The aortic annulus, aortic valve, and coronary ostia were reliably evaluable in all patients. Vascular contrast was rated excellent in both groups. High-pitch dual-source CTA of the whole aorta is a robust and dose-efficient examination strategy for the evaluation of aortic pathologies whether or not ECG gating is used. Copyright © 2015 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  11. Estimation and comparison of the radiation effective dose during coronary computed tomography angiography examinations on single-source 64-MDCT and dual-source 128-MDCT.

    PubMed

    Khoramian, Daryoush; Sistani, Soroush

    2017-09-14

    To estimate and compare the radiation dose associated with coronary computed tomography angiography (CCTA) examinations on two multi-detector CT scanners (MDCT), 64-MDCT and 128-MDCT, in daily practice. Scan parameters of 90 patients undergoing retrospective electrocardiographic gating spiral CCTA exam were recorded during a period on a single-source 64-MDCT and a dual-source 128-MDCT, and average scan parameters were derived that were used for dosimetry. The computed tomography dose index (CTDI) with a pencil ionisation chamber and polymethyl methacrylate body phantom with diameter of 32 cm was measured on both scanners. The dose-length product (DLP) was calculated and the DLP to effective dose conversion factor (for chest scan at 120 kV of 0.014 mSv mGy(-1) cm(-1)) was used to estimate effective dose (ED). Patients' heart rate, scan length, pitch factor, CTDIv, DLP and ED for 128-MDCT were 64 (5) (beats min(-1)), 161 (10) (mm), 0.26, 47 (12) (mGy), 769 (212) (mGy cm) and 10.3 (3.1) (mSv), respectively [mean (one standard deviation)]. Patients' heart rate, scan length, pitch factor, CTDIv, DLP and ED for 64-MDCT were 60 (7) (beats min(-1)), 172 (14) (mm), 0.2, 60 (6) (mGy), 1068 (98) (mGy cm) and 14.9 (1.4) (mSv), respectively. Our results indicated that the CTDIv, DLP and the effective dose with 128-MDCT is significantly lower than with 64-MDCT (p < 0.05). As differences between the exposure parameter mAs on two CT scanners was not significant (p > 0.05) and the kV was constant for both scanners (120 kV), the differences resulted from a shorter scan length on the 128-MDCT and use of a higher pitch factor (0.26 and 0.2 in the 128-MDCT and 64-MDCT, respectively). Comparison with other published studies confirms the findings and indicates methods for reducing patient dose.

  12. Automated attenuation-based tube voltage selection for body CTA: Performance evaluation of 192-slice dual-source CT.

    PubMed

    Winklehner, Anna; Gordic, Sonja; Lauk, Eliane; Frauenfelder, Thomas; Leschka, Sebastian; Alkadhi, Hatem; Husarik, Daniela B

    2015-08-01

    To assess radiation dose and image quality in body CT-angiography (CTA) with automated attenuation-based tube voltage selection (ATVS) on a 192-slice dual-source CT (DSCT). Forty patients (69.5 ± 9.6 years) who had undergone body CTA with ATVS (ref.kVp 100, ref.mAs 90) using a 2x192-slice CT in single-source mode were retrospectively included. All patients had undergone prior CTA with a 2x128-slice CT and ATVS with identical imaging and contrast media protocols, serving for comparison. Images were reconstructed with iterative reconstruction at similar strength levels. Radiation dose was determined. Image quality was assessed semi-quantitatively (1:excellent, 5:non-diagnostic), aortic attenuation, noise and CNR were determined. As compared to 128-slice DSCT, 192-slice DSCT selected tube voltages were lower in 30 patients (75 %), higher in 3 (7.5 %), and similar in 7 patients (17.5 %). CTDIvol was lower with 192-slice DSCT (4.7 ± 1.9 mGy vs. 5.8 ± 2.1 mGy; p < 0.001). Subjective image quality, mean aortic attenuation (342 ± 67HU vs. 268 ± 67HU) and CNR (9.8 ± 2.5 vs. 8.2 ± 2.9) were higher with 192-slice DSCT (all p < 0.01), all datasets being diagnostic. Our study suggests that ATVS of 192-slice DSCT for body CTA is associated with an improved image quality and further radiation dose reduction of 19 % compared to 128-slice DSCT. • 192-slice DSCT allows imaging from 70 kVp to 150 kVp at 10 kVp increments. • 192-slice DSCT allows for radiation-dose reduction in body-CTA with ATVS. • Subjective and objective image quality increase compared to 128-slice DSCT.

  13. Dual-Energy Computed Tomography Angiography of the Head and Neck With Single-Source Computed Tomography: A New Technical (Split Filter) Approach for Bone Removal.

    PubMed

    Kaemmerer, Nadine; Brand, Michael; Hammon, Matthias; May, Matthias; Wuest, Wolfgang; Krauss, Bernhard; Uder, Michael; Lell, Michael M

    2016-10-01

    Dual-energy computed tomographic angiography (DE-CTA) has been demonstrated to improve the visualization of the head and neck vessels. The aim of this study was to test the potential of split-filter single-source dual-energy CT to automatically remove bone from the final CTA data set. Dual-energy CTA was performed in 50 consecutive patients to evaluate the supra-aortic arteries, either to grade carotid artery stenosis or to rule out traumatic dissections. Dual-energy CTA was performed on a 128-slice single-source CT system equipped with a special filter array to separate the 120-kV spectrum into a high- and a low-energy spectrum for DE-based automated bone removal. Image quality of fully automated bone suppression and subsequent manual optimization was evaluated by 2 radiologists on maximum intensity projections using a 4-grade scoring system. The effect of image reconstruction with an iterative metal artifact reduction algorithm on DE postprocessing was tested using a 3-grade scoring system, and the time demand for each postprocessing step was measured. Two patients were excluded due to insufficient arterial contrast enhancement; in the remaining 48 patients, automated bone removal could be performed successfully. The addition of iterative metal artifact reduction algorithm improved image quality in 58.3% of the cases. After manual optimization, DE-CTA image quality was rated excellent in 7, good in 29, and moderate in 10 patients. Interobserver agreement was high (κ = 0.85). Stenosis grading was not influenced using DE-CTA with bone removal as compared with the original CTA. The time demand for DE image reconstruction was significantly higher than for single-energy reconstruction (42.1 vs 20.9 seconds). Our results suggest that bone removal in DE-CTA of the head and neck vessels with a single-source CT is feasible and can be performed within acceptable time and moderate user interaction.

  14. Effect of slice thickness on image noise and diagnostic content of single-source-dual energy computed tomography

    NASA Astrophysics Data System (ADS)

    Alshipli, Marwan; Kabir, Norlaili A.

    2017-05-01

    Computed tomography (CT) employs X-ray radiation to create cross-sectional images. Dual-energy CT acquisition includes the images acquired from an alternating voltage of X-ray tube: a low- and a high-peak kilovoltage. The main objective of this study is to determine the best slice thickness that reduces image noise with adequate diagnostic information using dual energy CT head protocol. The study used the ImageJ software and statistical analyses to aid the medical image analysis of dual-energy CT. In this study, ImageJ software and F-test were utilised as the combination methods to analyse DICOM CT images. They were used to investigate the effect of slice thickness on noise and visibility in dual-energy CT head protocol images. Catphan-600 phantom was scanned at different slice thickness values;.6, 1, 2, 3, 4, 5 and 6 mm, then quantitative analyses were carried out. The DECT operated in helical mode with another fixed scan parameter values. Based on F-test statistical analyses, image noise at 0.6, 1, and 2 mm were significantly different compared to the other images acquired at slice thickness of 3, 4, 5, and 6 mm. However, no significant differences of image noise were observed at 3, 4, 5, and 6 mm. As a result, better diagnostic image value, image visibility, and lower image noise in dual-energy CT head protocol was observed at a slice thickness of 3 mm.

  15. Compact High-Repetition-Rate Monochromatic Terahertz Source Based on Difference Frequency Generation from a Dual-Wavelength Nd:YAG Laser and DAST Crystal

    NASA Astrophysics Data System (ADS)

    Zhong, Kai; Mei, Jialin; Wang, Maorong; Liu, Pengxiang; Xu, Degang; Wang, Yuye; Shi, Wei; Yao, Jianquan; Teng, Bing; Xiao, Yong

    2017-01-01

    Although high-repetition-rate dual-wavelength Nd:YAG lasers at 1319 and 1338 nm have been realized for quite a long time, we have employed it in generating monochromatic terahertz (THz) wave in this paper for the first time. The dual-wavelength laser was LD-end-pumped and acousto-optically (AO) Q-switched with the output power of watt level operating at different repetition rates from 5.5 to 30 kHz. Using a 0.6-mm-thick organic nonlinear crystal DAST for difference frequency generation (DFG), a compact terahertz source was achieved at 3.28 THz. The maximum average output power was about 0.58 μW obtained at a repetition rate of 5.5 kHz, corresponding to the conversion efficiency of about 6.4 × 10-7. The output power scaling is still feasible with higher pump power and a longer nonlinear DFG crystal. Owing to the compactness of the dual-wavelength laser and the nonlinear crystal, a palm-top terahertz source is expected for portable applications such as imaging and so on.

  16. Plasma characteristics of single- and dual-electrode ion source systems utilized in low-energy ion extraction

    SciTech Connect

    Vasquez, M. R.; Tokumura, S.; Kasuya, T.; Wada, M.

    2014-02-15

    Discharge characteristics in the upstream as well as in the downstream regions of a 50-eV positive ion beam were measured along the beam axis. Single- and dual-electrode configurations made of 0.1-mm diameter tungsten wires were tested. By varying the upstream discharge parameters, the shape of the sheath edge around the extractors, which can either be “planar” or “cylindrical,” can be controlled. The sheath eventually affected the simultaneous extraction of ions and neutralizing electrons. The dual-electrode configuration at the lower discharge current, revealed a homogeneous discharge downstream. At this condition, the edge of the sheath can be inferred to be “planar” which allowed the uniform extraction and propagation of low-energy ions at longer distances. The dual-electrode configuration was capable of transmitting low-energy ions up to 70 mm downstream.

  17. Coronary stent imaging with dual-source CT: assessment of lumen visibility using different convolution kernels and postprocessing filters.

    PubMed

    Ulrich, Anne; Burg, Matthias C; Raupach, Rainer; Bunck, Alexander; Schuelke, Christoph; Maintz, David; Heindel, Walter; Seifarth, Harald

    2015-01-01

    Assesment of the coronary arteries after stent placement using coronary computed tomography angiography (CCTA) currently requires reconstruction of images with soft kernels for the assessment of atherosclerotic plaques and dedicated edge enhancing kernels for the evaluation of the stent lumen. To evaluate a two-dimensional filter tool that provides instant postprocessing of images reconstructed with soft kernels into edge-enhanced images and vice versa and thus may eliminate the need for two separate reconstrcutions for the assessment of coronary artery stents using CCTA. Twenty stents with a diameter of 3.0 mm placed in a vascular phantom were scanned with a dual-source CT using standard parameters. Images were reconstructed with a soft B30f and an edge-enhancing B46f kernel and postprocessed with the corresponding filter algorithm (F30 for B30f images; F46 for B46f images). The resulting four data-sets were evaluated for lumen visibility, intraluminal attenuation, and image noise by two independent readers. Results were validated in vivo against invasive coronary angiography in data-sets from patients with coronary artery stents. Average intraluminal attenuation was 552.6 HU, 527.3 HU, 207.9 HU, and 267.5 HU for B30f, F30, B46f, and F46 images, respectively (P < 0.0001). Average image noise was 11.3, 10.6, 19.2, and 15.0 HU, respectively (P < 0.0001). The visible stent diameter was significantly higher in the B46f (59.6%) and F46 images (54%) compared to the B30f (48.3%) and F30 (51.5%) images (P < 0.0001). In the patient study, lumen assessability was significantly better in B46f images than in F46 images. Sensitivity for stenosis detection was best in the original B46f images with a sensitivity of 67% and a specificity of 94%. The postprocessing filter reduces image noise, however currently it does not offer an alternative to image reconstruction using the edge-enhancing kernels for the evaluation of the stent lumen. © The Foundation Acta

  18. Contrast material injection protocol with the flow rate adjusted to the heart rate for dual source CT coronary angiography.

    PubMed

    Zhu, Xiaomei; Chen, Wenping; Li, Mei; Xu, Yi; Xu, Hai; Zhu, Yinsu; Wang, Dehang; Tang, Lijun

    2012-08-01

    To investigate the effect on coronary arterial attenuations of contrast material flow rate adjusted to a patient's heart rate during dual source CT coronary angiography (DSCT-CCTA). A total of 296 consecutive patients (mean age: 58.7 years) undergoing DSCT-CCTA without previous coronary stent placement, bypass surgery, congenital or valvular heart disease were included. The image acquisition protocol was standardized (120 kV, 380 mAs) and retrospective electrocardiograph (ECG) gating was used. Patients were randomly assigned to one of three groups [flow rate: G1: dosage/16, G2: dosage/(scan time +8), G3: fixed flow rate]. The groups were compared with respect to the attenuations of the ascending aorta (AA) above coronary ostia, the left main coronary artery (LM), the proximal right coronary artery (RCA), the left anterior descending artery (LAD), the left circumflex artery (LCX), and the contrast to noise ratio of the LM (LM(CNR)) and the proximal RCA (RCA(CNR)). Correlations between heart rate and attenuation of the coronary arteries were evaluated in three groups with linear regression. There was no significant difference in the three groups among the mean attenuations of AA (P = 0.141), LM (P = 0.068), RCA (P = 0.284), LM(CNR) (P = 0.598) and RCA(CNR) (P = 0.546). The attenuations of the LAD and the LCX in group 1 were slightly higher than those in group 2 and 3 (P < 0.05). In group 1, the attenuations of the AA (P < 0.01), LM (P < 0.01), RCA (P < 0.01), LAD (P = 0.02) and LCX (P < 0.01) decreased, respectively, with an increasing heart rate. A similar finding was detected in group 3 (AA: P < 0.01, LM: P < 0.01, RCA: P < 0.01, LAD: P < 0.01 and LCX: P < 0.01). In contrast, the attenuations of the AA (P = 0.55), LM (P = 0.27), RCA (P = 0.77), LAD (P = 0.22) and LCX (P = 0.74) had no significant correlation with heart rate in group 2. In all three groups, LM(CNR) (P = 0.77, 0.69 and 0.73 respectively) and RCA(CNR) (P = 0.75, 0.39 and 0.61 respectively) had no

  19. Identification of benign and malignant thyroid nodules by in vivo iodine concentration measurement using single-source dual energy CT

    PubMed Central

    Gao, Shun-Yu; Zhang, Xiao-Yan; Wei, Wei; Li, Xiao-Ting; Li, Yan-Ling; Xu, Min; Sun, Ying-Shi; Zhang, Xiao-Peng

    2016-01-01

    Abstract This study proposed to determine whether in vivo iodine concentration measurement by single-source dual energy (SSDE) CT can improve differentiation between benign and malignant thyroid nodules. In total, 53 patients presenting with thyroid nodules underwent SSDE CT scanning. Iodine concentrations were measured for each nodule and normal thyroid tissue using the GSI-viewer image analysis software. A total of 26 thyroid nodules were malignant in 26 patients and confirmed by surgery; 33 nodules from 27 patients were benign, with 10 confirmed by surgery and others after follow-up. Iodine concentrations with plain CT were significantly lower in malignant than benign nodules (0.47 ± 0.20 vs 1.17 ± 0.38 mg/mL, P = 0.00). Receiver operating characteristic (ROC) curve showed an area under the curve (AUC) of 0.93; with a cutoff of 0.67, iodine concentration showed 92.3% sensitivity and 88.5% specificity in diagnosing malignancy. Iodine concentration obtained by enhanced and plain CT were significantly higher in malignant than benign nodules (9.05 ± 3.35 vs 3.46 ± 2.24 mg/mL, P = 0.00). ROC curve analysis showed an AUC of 0.93; with a cutoff value of 3.37, iodine concentration displayed 78% sensitivity, 95% specificity in diagnosing malignancy. Combining unenhanced with enhanced iodine concentrations, the diagnostic equation was: Y = –8.641 × unenhanced iodine concentration + 0.663 × iodine concentration. ROC curve showed an AUC of 0.98 (95% CI, 0.94, 1.00). With Y ≥ –2 considered malignancy, diagnostic sensitivity and specificity were 96%, 96.3%, respectively. This study concluded that SSDE CT can detect the differences in iodine uptake and blood supply between benign and malignant thyroid lesions. PMID:27684811

  20. Automatic vs semi-automatic global cardiac function assessment using 64-row CT

    PubMed Central

    Greupner, J; Zimmermann, E; Hamm, B; Dewey, M

    2012-01-01

    Objective Global cardiac function assessment using multidetector CT (MDCT) is time-consuming. Therefore we sought to compare an automatic software tool with an established semi-automatic method. Methods A total of 36 patients underwent CT with 64×0.5 mm detector collimation, and global left ventricular function was subsequently assessed by two independent blinded readers using both an automatic region-growing-based software tool (with and without manual adjustment) and an established semi-automatic software tool. We also analysed automatic motion mapping to identify end-systole. Results The time needed for assessment using the semi-automatic approach (12:12±6:19 min) was reduced by 75–85% with the automatic software tool (unadjusted, 01:34±0:29 min, adjusted, 02:53±1:19 min; both p<0.001). There was good correlation (r=0.89; p<0.001) for the ejection fraction (EF) between the adjusted automatic (58.6±14.9%) and the semi-automatic (58.0±15.3%) approaches. Also the manually adjusted automatic approach led to significantly smaller limits of agreement than the unadjusted automatic approach for end-diastolic volume (±36.4 ml vs ±58.5 ml, p>0.05). Using motion mapping to automatically identify end-systole reduced analysis time by 95% compared with the semi-automatic approach, but showed inferior precision for EF and end-systolic volume. Conclusion Automatic function assessment using MDCT with manual adjustment shows good agreement with an established semi-automatic approach, while reducing the analysis by 75% to less than 3 min. This suggests that automatic CT function assessment with manual correction may be used for fast, comfortable and reliable evaluation of global left ventricular function. PMID:22045953

  1. Vascular air embolism after contrast administration on 64 row multiple detector computed tomography: A prospective analysis.

    PubMed

    Sodhi, Kushaljit S; Saxena, Akshay K; Chandrashekhar, Guruprasadh; Bhatia, Anmol; Singhi, Sunit; Agarwal, Ritesh; Khandelwal, Niranjan

    2015-01-01

    Vascular air embolism is being progressively reported as a nonfatal event with increase in use of computed tomography (CT) as a diagnostic modality. This study was undertaken to study the frequency and site of vascular air embolism in patients undergoing contrast-enhanced CT (CECT) and analyze CT parameters that influence its prevalence and final outcome. This was a prospective study approved by departmental ethics committee. Presence and location of air emboli in 200 patients who underwent CT scan of chest on a 64 detector scanner was recorded. We analyzed the role of various factors that could influence the prevalence of air embolism after injection of contrast in CECT scans. These factors included the amount of contrast injected, rate of flow of injection of contrast, site of injection of contrast, and size of intravenous access line. Iatrogenic vascular air emboli were seen in 14 patients (7% of total). The locations of air emboli were main pulmonary artery in 12 (6% of total), left brachiocephalic vein in 3 (1.5% of total), right atrial appendage in 4 (2% of total), and superior vena cava (SVC) in 1 (0.5%) patient. There was no association between volume of contrast, flow rate, site and size of intravenous access, and presence of air emboli. Radiologists as well as referring physicians should be aware of vascular air embolism, which can occur after contrast injection in patients undergoing CT scan. Age, volume of contrast, flow rate of pressure injector, and site and size of venous cannula do not influence the likelihood or incidence of detection of venous air emboli on CT scans.

  2. Value of Virtual Colonoscopy with 64 Row CT in Evaluation of Colorectal Cancer

    PubMed Central

    Zaleska-Dorobisz, Urszula; Łasecki, Mateusz; Nienartowicz, Ewa; Pelak, Joanna; Słonina, Joanna; Olchowy, Cyprian; Ścieżka, Marek; Sąsiadek, Marek

    2014-01-01

    Summary Background Virtual colonoscopy (VC) enables three-dimensional view of walls and internal lumen of the colon as a result of reconstruction of multislice CT images. The role of VC in diagnosis of the colon abnormalities systematically increases, and in many medical centers all over the world is carried out as a screening test of patients with high risk of colorectal cancer. Material/Methods We analyzed results of virtual colonoscopy of 360 patients with clinical suspicion of colorectal cancer. Sensitivity and specificity of CT colonoscopy for detection of colon cancers and polyps were assessed. Results Results of our research have shown high diagnostic efficiency of CT colonoscopy in detection of focal lesions in large intestine of 10 mm or more diameter. Sensitivity was 85.7%, specificity 89.2%. Conclusions Virtual colonoscopy is noninvasive and well tolerated by patients imaging method, which permits for early detection of the large intestine lesions with specificity and sensitivity similar to classical colonoscopy in screening exams in patients suspected for colorectal cancer. Good preparation of the patients for the examination is very important for proper diagnosis and interpretation of this imaginge procedure. PMID:25302086

  3. Third-generation dual-source 70-kVp chest CT angiography with advanced iterative reconstruction in young children: image quality and radiation dose reduction.

    PubMed

    Rompel, Oliver; Glöckler, Martin; Janka, Rolf; Dittrich, Sven; Cesnjevar, Robert; Lell, Michael M; Uder, Michael; Hammon, Matthias

    2016-04-01

    Many technical updates have been made in multi-detector CT. To evaluate image quality and radiation dose of high-pitch second- and third-generation dual-source chest CT angiography and to assess the effects of different levels of advanced modeled iterative reconstruction (ADMIRE) in newborns and children. Chest CT angiography (70 kVp) was performed in 42 children (age 158 ± 267 days, range 1-1,194 days). We evaluated subjective and objective image quality, and radiation dose with filtered back projection (FBP) and different strength levels of ADMIRE. For comparison were 42 matched controls examined with a second-generation 128-slice dual-source CT-scanner (80 kVp). ADMIRE demonstrated improved objective and subjective image quality (P < .01). Mean signal/noise, contrast/noise and subjective image quality were 11.9, 10.0 and 1.9, respectively, for the 80 kVp mode and 11.2, 10.0 and 1.9 for the 70 kVp mode. With ADMIRE, the corresponding values for the 70 kVp mode were 13.7, 12.1 and 1.4 at strength level 2 and 17.6, 15.6 and 1.2 at strength level 4. Mean CTDIvol, DLP and effective dose were significantly lower with the 70-kVp mode (0.31 mGy, 5.33 mGy*cm, 0.36 mSv) compared to the 80-kVp mode (0.46 mGy, 9.17 mGy*cm, 0.62 mSv; P < .01). The third-generation dual-source CT at 70 kVp provided good objective and subjective image quality at lower radiation exposure. ADMIRE improved objective and subjective image quality.

  4. Measurement of Opening and Closing Angles of Aortic Valve Prostheses In Vivo Using Dual-Source Computed Tomography: Comparison with Those of Manufacturers' in 10 Different Types.

    PubMed

    Suh, Young Joo; Kim, Young Jin; Hong, Yoo Jin; Lee, Hye-Jeong; Hur, Jin; Im, Dong Jin; Kim, Yun Jung; Choi, Byoung Wook

    2015-01-01

    The aims of this study were to compare opening and closing angles of normally functioning mechanical aortic valves measured on dual-source computed tomography (CT) with the manufacturers' values and to compare CT-measured opening angles according to valve function. A total of 140 patients with 10 different types of mechanical aortic valves, who underwent dual-source cardiac CT, were included. Opening and closing angles were measured on CT images. Agreement between angles in normally functioning valves and the manufacturer values was assessed using the interclass coefficient and the Bland-Altman method. CT-measured opening angles were compared between normal functioning valves and suspected dysfunctioning valves. The CT-measured opening angles of normally functioning valves and manufacturers' values showed excellent agreement for seven valve types (intraclass coefficient [ICC], 0.977; 95% confidence interval [CI], 0.962-0.987). The mean differences in opening angles between the CT measurements and the manufacturers' values were 1.2° in seven types of valves, 11.0° in On-X valves, and 15.5° in ATS valves. The manufacturers' closing angles and those measured by CT showed excellent agreement for all valve types (ICC, 0.953; 95% CI, 0.920-0.972). Among valves with suspected dysfunction, those with limitation of motion (LOM) and an increased pressure gradient (PG) had smaller opening angles than those with LOM only (p < 0.05). Dual-source cardiac CT accurately measures opening and closing angles in most types of mechanical aortic valves, compared with the manufacturers' values. Opening angles on CT differ according to the type of valve dysfunction and a decreased opening angle may suggest an elevated PG.

  5. Neural correlates of confidence during item recognition and source memory retrieval: evidence for both dual-process and strength memory theories.

    PubMed

    Hayes, Scott M; Buchler, Norbou; Stokes, Jared; Kragel, James; Cabeza, Roberto

    2011-12-01

    Although the medial-temporal lobes (MTL), PFC, and parietal cortex are considered primary nodes in the episodic memory network, there is much debate regarding the contributions of MTL, PFC, and parietal subregions to recollection versus familiarity (dual-process theory) and the feasibility of accounts on the basis of a single memory strength process (strength theory). To investigate these issues, the current fMRI study measured activity during retrieval of memories that differed quantitatively in terms of strength (high vs. low-confidence trials) and qualitatively in terms of recollection versus familiarity (source vs. item memory tasks). Support for each theory varied depending on which node of the episodic memory network was considered. Results from MTL best fit a dual-process account, as a dissociation was found between a right hippocampal region showing high-confidence activity during the source memory task and bilateral rhinal regions showing high-confidence activity during the item memory task. Within PFC, several left-lateralized regions showed greater activity for source than item memory, consistent with recollective orienting, whereas a right-lateralized ventrolateral area showed low-confidence activity in both tasks, consistent with monitoring processes. Parietal findings were generally consistent with strength theory, with dorsal areas showing low-confidence activity and ventral areas showing high-confidence activity in both tasks. This dissociation fits with an attentional account of parietal functions during episodic retrieval. The results suggest that both dual-process and strength theories are partly correct, highlighting the need for an integrated model that links to more general cognitive theories to account for observed neural activity during episodic memory retrieval.

  6. A dual-plane co-RASOR technique for accurate and rapid tracking and position verification of an Ir-192 source for single fraction HDR brachytherapy.

    PubMed

    de Leeuw, Hendrik; Moerland, Marinus A; van Vulpen, Marco; Seevinck, Peter R; Bakker, Chris J G

    2013-11-07

    Effective high-dose-rate (HDR) treatment requires accurate and independent treatment verification to ensure that the treatment proceeds as prescribed, in particular if a high dose is given, as in single fraction therapy. Contrary to CT imaging and fluoroscopy, MR imaging provides high soft tissue contrast. Conventional MR techniques, however, do not offer the temporal resolution in combination with the 3D spatial resolution required for accurate brachytherapy source localization. We have developed an MR imaging method (center-out RAdial Sampling with Off-Resonance (co-RASOR)) that generates high positive contrast in the geometrical center of field perturbing objects, such as HDR brachytherapy sources. co-RASOR generates high positive contrast in the geometric center of an Ir-192 source by applying a frequency offset to center-out encoded data. To obtain high spatial accuracy in 3D with adequate temporal resolution, two orthogonal center-out encoded 2D images are applied instead of a full 3D acquisition. Its accuracy in 3D is demonstrated by 3D MRI and CT. The 2D images show high positive contrast in the geometric center of non-radioactive Ir-192 sources, with signal intensities up to 160% of the average signal intensity in the surrounding medium. The accuracy with which the center of the Ir-192 source is located by the dual-plane MRI acquisition corresponds closely to the accuracy obtained by 3D MRI and CT imaging. The positive contrast is shown to be obtained in homogeneous and in heterogeneous tissue. The dual-plane MRI technique allows the brachytherapy source to be tracked in 3D with millimeter accuracy with a temporal resolution of approximately 4 s.

  7. A dual-plane co-RASOR technique for accurate and rapid tracking and position verification of an Ir-192 source for single fraction HDR brachytherapy

    NASA Astrophysics Data System (ADS)

    de Leeuw, Hendrik; Moerland, Marinus A.; van Vulpen, Marco; Seevinck, Peter R.; Bakker, Chris J. G.

    2013-11-01

    Effective high-dose-rate (HDR) treatment requires accurate and independent treatment verification to ensure that the treatment proceeds as prescribed, in particular if a high dose is given, as in single fraction therapy. Contrary to CT imaging and fluoroscopy, MR imaging provides high soft tissue contrast. Conventional MR techniques, however, do not offer the temporal resolution in combination with the 3D spatial resolution required for accurate brachytherapy source localization. We have developed an MR imaging method (center-out RAdial Sampling with Off-Resonance (co-RASOR)) that generates high positive contrast in the geometrical center of field perturbing objects, such as HDR brachytherapy sources. co-RASOR generates high positive contrast in the geometric center of an Ir-192 source by applying a frequency offset to center-out encoded data. To obtain high spatial accuracy in 3D with adequate temporal resolution, two orthogonal center-out encoded 2D images are applied instead of a full 3D acquisition. Its accuracy in 3D is demonstrated by 3D MRI and CT. The 2D images show high positive contrast in the geometric center of non-radioactive Ir-192 sources, with signal intensities up to 160% of the average signal intensity in the surrounding medium. The accuracy with which the center of the Ir-192 source is located by the dual-plane MRI acquisition corresponds closely to the accuracy obtained by 3D MRI and CT imaging. The positive contrast is shown to be obtained in homogeneous and in heterogeneous tissue. The dual-plane MRI technique allows the brachytherapy source to be tracked in 3D with millimeter accuracy with a temporal resolution of approximately 4 s.

  8. Cardiac MOLLI T1 mapping at 3.0 T: comparison of patient-adaptive dual-source RF and conventional RF transmission.

    PubMed

    Rasper, Michael; Nadjiri, Jonathan; Sträter, Alexandra S; Settles, Marcus; Laugwitz, Karl-Ludwig; Rummeny, Ernst J; Huber, Armin M

    2017-01-30

    To prospectively compare image quality and myocardial T1 relaxation times of modified Look-Locker inversion recovery (MOLLI) imaging at 3.0 T (T) acquired with patient-adaptive dual-source (DS) and conventional single-source (SS) radiofrequency (RF) transmission. Pre- and post-contrast MOLLI T1 mapping using SS and DS was acquired in 27 patients. Patient wise and segment wise analysis of T1 times was performed. The correlation of DS MOLLI measurements with a reference spin echo sequence was analysed in phantom experiments. DS MOLLI imaging reduced T1 standard deviation in 14 out of 16 myocardial segments (87.5%). Significant reduction of T1 variance could be obtained in 7 segments (43.8%). DS significantly reduced myocardial T1 variance in 16 out of 25 patients (64.0%). With conventional RF transmission, dielectric shading artefacts occurred in six patients causing diagnostic uncertainty. No according artefacts were found on DS images. DS image findings were in accordance with conventional T1 mapping and late gadolinium enhancement (LGE) imaging. Phantom experiments demonstrated good correlation of myocardial T1 time between DS MOLLI and spin echo imaging. Dual-source RF transmission enhances myocardial T1 homogeneity in MOLLI imaging at 3.0 T. The reduction of signal inhomogeneities and artefacts due to dielectric shading is likely to enhance diagnostic confidence.

  9. Screening for coronary artery disease in respiratory patients: comparison of single- and dual-source CT in patients with a heart rate above 70 bpm.

    PubMed

    Pansini, Vittorio; Remy-Jardin, Martine; Tacelli, Nunzia; Faivre, Jean-Baptiste; Flohr, Thomas; Deken, Valérie; Duhamel, Alain; Remy, Jacques

    2008-10-01

    To evaluate the assessibility of coronary arteries in respiratory patients with high heart rates. This study was based on the comparative analysis of two paired populations of 54 patients with a heart rate >70 bpm evaluated with dual-source (group 1) and single-source (group 2) CT. The mean heart rate was 89.1 bpm in group 1 and 86.7 bpm in group 2 (P=0.26). The mean number of assessable segments per patient was significantly higher in group 1 compared to group 2 (P dual-source CT suggests that high heart rates should no longer be considered as contraindications for ECG-gated CT angiograms of the chest whenever clinically relevant.

  10. Liver: segment-specific analysis of B1 field homogeneity at 3.0-T MR imaging with single-source versus dual-source parallel radiofrequency excitation.

    PubMed

    Pazahr, Shila; Fischer, Michael Alexander; Chuck, Natalie; Luechinger, Roger; Schick, Fritz; Nanz, Daniel; Boss, Andreas

    2012-11-01

    To measure B1 field distribution in different liver segments with and without dual transmission and to quantify the contrast-to-noise ratio (CNR) between normal liver tissue and segmental venous vessels on standard clinical 3.0-T liver magnetic resonance (MR) images. This prospective study was approved by the local ethics committee. All subjects gave written informed consent. Six patients with liver lesions and nine healthy volunteers were included. Average hepatic B1 field values in all Couinaud liver segments were assessed by using actual flip-angle imaging (first and second repetition times msec/echo time msec: 72, 192/2.2; transmission angle: 60°) for both single and dual transmission in a 3.0-T MR imaging unit that allowed both transmission modes. Additionally, two-dimensional T1-weighted gradient-echo (repetition time msec/echo time msec, 180/2.3; transmission angle, 55°) and T2-weighted single-shot fast spin-echo images (1501/80) were acquired. Average CNR between liver parenchyma and segmental veins were measured in each segment. Two-sided paired Student t tests were used for statistical evaluation. Two blinded radiologists independently identified lesions in images from acquisitions in both transmission modes. Mean flip angles achieved with conventional single transmission were 44%-53% of the nominal value in segments II-IV and 67% and 63% of the nominal value in segments VI and VII, respectively, and were less than 77% in all segments. Mean actual flip angles measured for dual transmission were between 82% and 100% of the nominal value in all segments. T1-weighted single-transmission images exhibited areas of low B1 field strength with reduced image contrast. T2-weighted single-transmission images displayed significantly reduced signal intensity but nearly unchanged contrast weighting in these areas. On T1-weighted dual-transmission images, the two readers detected 22 and 14 additional lesions that they did not identify on the single-transmission images

  11. Dual-source parallel radiofrequency excitation ACR phantom magnetic resonance imaging at 3 T: Assessment of the effect of image quality on high-contrast spatial resolution, percent signal ghosting, and low-contrast object detectability in comparison with conventional single-source transmission

    NASA Astrophysics Data System (ADS)

    Lee, Kyung-Bae; Park, Yong-Sung; Choe, Bo-Young

    2013-10-01

    The purpose of the present study was to assess dual-source parallel radiofrequency (RF) excitation American College of Radiology (ACR) phantom magnetic resonance (MR) imaging at 3T compared with conventional single-source RF transmission and compared with the standard ACR MRI phantom test. We used a 3T MR scanner equipped with dual-source parallel RF excitation and an 8-channel head phased array coil. We employed T1- and T2-weighted fast spin echo (FSE) pulse sequences for an assessment of the impact of image quality on high-contrast spatial resolution, percent signal ghosting and low-contrast object detectability following the ACR MRI quality control (QC) manual. With geometric accuracy and identical slice locations, dual RFs using dual-source parallel RF excitation MR showed an advantage over single RF using dual-source parallel RF excitation MR and conventional MR in terms of high-contrast spatial resolution (p < 0.010), percent signal ghosting (p < 0.010), and low-contrast object detectability (p < 0.010). The quality of the image from the dual-source parallel RF excitation MR equipment was superior to that of the image from conventional MR equipment for the ACR phantom. We need to pursue dual-source parallel RF excitation MR studies involving various clinical cases.

  12. Indirect computed tomography venography of the lower extremities using single-source dual-energy computed tomography: advantage of low-kiloelectron volt monochromatic images.

    PubMed

    Kulkarni, Naveen M; Sahani, Dushyant V; Desai, Gaurav S; Kalva, Sanjeeva P

    2012-07-01

    To study the performance of dual-energy indirect computed tomography (CT) venography from single-source dual-energy CT in the assessment of lower extremity deep venous thrombosis (DVT). In a retrospective study, 110 patients suspected to have pulmonary embolism (PE) underwent dual-energy CT venography on a single-source dual-energy CT scanner as a part of CT pulmonary angiography protocol at 3 minutes after injection of contrast material. Two radiologists evaluated 50-kiloelectron volt (keV) and 70-keV monochromatic images reconstructed from a dual-energy CT scan for image quality, image noise, venous contrast, and confidence level in interpretation for DVT using a scale of 1-5. In addition, a combined 50-keV and 70-keV data set was assessed for confidence level in image interpretation. Attenuation, contrast-to-noise ratio (CNR), and objective noise were measured in bilateral common femoral and popliteal veins. Data were analyzed using Student t test and Wilcoxon rank sum test. Radiation dose was measured for dual-energy CT venography protocol. A diagnosis of DVT was made in 8 of 110 patients (7.27%). The subjective image quality was comparable between 50-keV and 70-keV images (4.3 vs 4.5; P > .05). The subjective venous contrast opacification (4.7 vs 3.5; P = .0036) and confidence (4.8 vs 3.9; P = .0028) in image interpretation were superior at 50 keV. Confidence level for interpretation on combined 50-keV and 70-keV series (score 4.7) was similar to that for 50-keV series (score 4.8). Compared with 70-keV data, 50-keV data yielded 90% increase in intravascular CT attenuation (207.4 Hounsfield units [HU] ± 39.0 vs 106.8 HU ± 7.6; P <.0001) and higher CNR (10.7 ± 4.07 vs 7.2 ± 4.1; P = .0001) of the deep veins. However, objective noise at 50 keV was higher (14.8 HU vs 6.5 HU; P = .0031). Because of inadequate contrast opacification, 6% of CT venography studies were deemed suboptimal for rendering a diagnostic interpretation on 70-keV images, but these images

  13. Application of flash dual-source CT at low radiation dose and low contrast medium dose in triple-rule-out (tro) examination.

    PubMed

    Chen, Hong-Liang; Chen, Tian-Wu; Qiu, Li-Hua; Diao, Xian-Ming; Zhang, Chao; Chen, Li

    2015-01-01

    To evaluate the clinical imaging capacity of FLASH dual-source CT at low radiation dose and low contrast medium dose in thoracic aorta, pulmonary artery & vein and coronary artery. One hundred and eight patients of thoracalgia were randomly divided into two groups; 60 cases (group A) received dual-source CT scan in flash model at 100 KV and contrast medium dose of 74 ml combined with digital subtraction angiography (DSA) examination; 48 cases (group B) received retrospectively. ECG-triggered high-pitch spiral acquisition at 120 KV and contrast medium dose of 101 ml. Several image reconstruction techniques were adopted for coronary artery, pulmonary artery and aorta. The imaging quality and the diagnostic value of this technique were evaluated. Coronary artery stenosis of group A was compared against the results of DSA examination. The scan time in group A was obviously shorter than that of group B, i.e., t=0.7±0.1 s in group A and t=7.7±1.7 s in group A. The image reconstruction phase of coronary artery was 70.4±15.6% in group A, and the systolic phase accounted for 13.3% of the optimal reconstruction phase. Compared with group B, the radiation dose of group A decreased obviously, i.e. ED=2.7±0.7 mSv for group A and ED=21.6±6.0 mSv for group B. Moreover, less contrast agent was consumed in group A than in group B, which was 74 ml in group A and 101 ml in group B. The image quality of aorta and pulmonary artery & vein was grade 1 for all cases in group A, which was the same as with group B. The coronary artery images of group A had better quality, with score of 2.9±0.1. Of 780 segments, only 2 segments could be effectively diagnosed, showing no statistically significant differences from group B (P>0.05). The coronary artery stenosis revealed by dual-source CT for group A was not significantly different from that by DSA (P>0.05). FLASH dual-source CT scan at reduced radiation dose and reduced contrast medium dose used for triple-rule-out (TRO) examination

  14. Application of flash dual-source CT at low radiation dose and low contrast medium dose in triple-rule-out (tro) examination

    PubMed Central

    Chen, Hong-Liang; Chen, Tian-Wu; Qiu, Li-Hua; Diao, Xian-Ming; Zhang, Chao; Chen, Li

    2015-01-01

    Objective: To evaluate the clinical imaging capacity of FLASH dual-source CT at low radiation dose and low contrast medium dose in thoracic aorta, pulmonary artery & vein and coronary artery. Method: One hundred and eight patients of thoracalgia were randomly divided into two groups; 60 cases (group A) received dual-source CT scan in flash model at 100 KV and contrast medium dose of 74 ml combined with digital subtraction angiography (DSA) examination; 48 cases (group B) received retrospectively. ECG-triggered high-pitch spiral acquisition at 120 KV and contrast medium dose of 101 ml. Several image reconstruction techniques were adopted for coronary artery, pulmonary artery and aorta. The imaging quality and the diagnostic value of this technique were evaluated. Coronary artery stenosis of group A was compared against the results of DSA examination. Results: The scan time in group A was obviously shorter than that of group B, i.e., t=0.7±0.1 s in group A and t=7.7±1.7 s in group A. The image reconstruction phase of coronary artery was 70.4±15.6% in group A, and the systolic phase accounted for 13.3% of the optimal reconstruction phase. Compared with group B, the radiation dose of group A decreased obviously, i.e. ED=2.7±0.7 mSv for group A and ED=21.6±6.0 mSv for group B. Moreover, less contrast agent was consumed in group A than in group B, which was 74 ml in group A and 101 ml in group B. The image quality of aorta and pulmonary artery & vein was grade 1 for all cases in group A, which was the same as with group B. The coronary artery images of group A had better quality, with score of 2.9±0.1. Of 780 segments, only 2 segments could be effectively diagnosed, showing no statistically significant differences from group B (P>0.05). The coronary artery stenosis revealed by dual-source CT for group A was not significantly different from that by DSA (P>0.05). Conclusion: FLASH dual-source CT scan at reduced radiation dose and reduced contrast medium dose used for

  15. Critical stenosis of a right ventricle to coronary artery fistula seen at dual-source CT in a newborn with pulmonary atresia and intact ventricular septum.

    PubMed

    Séguéla, Pierre-Emmanuel; Houyel, Lucile; Loget, Philippe; Piot, Jean-Dominique; Paul, Jean-François

    2011-08-01

    We report the case of a newborn with pulmonary atresia with intact ventricular septum and right ventricle-dependent coronary circulation. He died several weeks after a Blalock-Taussig procedure because of a progressive stenosis of the main coronary artery. We present echocardiographic and dual-source CT images of the stenosis, with autopsy correlation. To our knowledge, CT images of this quality have never been reported in a newborn. This case illustrates the extreme difficulty in prognosticating the outcome for these patients and underlines the need for a detailed neonatal coronary mapping to assess right ventricle-dependent coronary circulation.

  16. An Aneurysmal Left Circumflex Artery-to-Right Atrium Fistula in a Patient with Ischemic Symptoms: Accurate Diagnosis with Dual-Source CT Angiography

    SciTech Connect

    Oncel, Dilek Oncel, Guray

    2008-07-15

    In this report, we present a 55-year-old female patient with a left circumflex artery-to-right atrial fistula associated with a huge saccular aneurysm. She had undergone conventional angiography due to ischemic symptoms. In conventional angiography, a very dilated and tortuous vessel originating from the circumflex artery and continuous with a huge saccular aneurysm was visualized but the drainage site could not be demonstrated. With dual-source CT coronary angiography, the exact anatomy of this fistula was demonstrated and surgery was planned.

  17. The value of dual-source multi detector-row computed tomography in determining pulmonary blood supply in patients with pulmonary atresia with ventricular septal defect.

    PubMed

    Chaosuwannakit, Narumol; Makarawate, Pattarapong

    2017-07-13

    Primary evaluation of patients with pulmonary atresia with ventricular septal defect (PA-VSD) traditionally relies upon echocardiography and conventional cardiac angiography (CCA). CA is considered the gold standard for delineation of anatomy in children with pulmonary atresia with ventricular septal defect (PA with VSD). Data comparing CCA and dual-source multidetector-row computed tomography angiography (MDCT) in PA with VSD patients is limited. The objective of this study was to test the hypothesis that MDCT is equivalent to CCA for anatomic delineation in these patients. Twenty eight patients with PA with VSD were underwent CCA and MDCT in close proximity to each other without interval therapy. A retrospective review of these 28 patients was performed. All MDCT data of pulmonary artery morphology, MAPCAs and type of blood supply (dual versus single supply) were evaluated by a blinded experts and results were compared with CCA. 28 patients had adequate size right and left pulmonary arteries (21 confluent and 7 non-confluent). Seven patients had complete absence of native pulmonary artery and three patients had stenosis of distal branches of pulmonary arteries; all had major aortopulmonary collateral arteries (MAPCAs) from descending thoracic aorta and/or subclavian arteries. Sensitivity, specificity,positive and negative predictive value of MDCT for detecting confluent of pulmonary arteries, absence of native pulmonary artery and stenosis of pulmonary arteries were all 100%. Moreover accuracy of detecting MAPCAs were excellent. These results suggest that MDCT and CCA are equilavent in their ability to delineate pulmonary artery anatomy and MAPCAs. Dual source MDCT provides high diagnostic accuracy in evaluation of pulmonary blood supply in patients with PA-VSD and allow precise characterization of the condition of pulmonary arteries and MAPCAs which is of paramount importance in managing patients with PA-VSD.

  18. Microwave observation of H 3N-SO 3⋯H 2O using a concentric, dual-injection nozzle source

    NASA Astrophysics Data System (ADS)

    Hunt, S. W.; Brauer, C. S.; Craddock, M. B.; Higgins, K. J.; Nienow, A. M.; Leopold, K. R.

    2004-10-01

    The complex H 3N-SO 3⋯ H 2O is observed by pulsed nozzle Fourier transform microwave spectroscopy using a newly designed concentric, dual-injection nozzle source. This source allows two reactive species to be injected independently into a seeded supersonic expansion by introducing gases through a pair of concentric hypodermic needles situated downstream of the nozzle orifice. Microwave spectra of the parent form of H 3N-SO 3⋯H 2O, as well as nine isotopically substituted derivatives are observed, and the N-S bond length is estimated to be 1.83(13) Å. This value is in reasonable agreement with previous theoretical calculations and suggests that the complexation of H 3N-SO 3 with water produces a substantial contraction of the nitrogen-sulfur bond. The spectrum shows no evidence of internal motion of the water subunit.

  19. Accuracy of dual-source CT to identify significant coronary artery disease in patients with uncontrolled hypertension presenting with chest pain: comparison with coronary angiography.

    PubMed

    Marwan, Mohamed; Pflederer, Tobias; Schepis, Tiziano; Seltmann, Martin; Klinghammer, Lutz; Muschiol, Gerd; Ropers, Dieter; Daniel, Werner G; Achenbach, Stephan

    2012-06-01

    It has been previously reported that the sensitivity and specificity of multislice CT for detecting significant CAD (coronary artery disease) is high. Chest pain is a common presentation in patients with uncontrolled hypertension. We investigated the sensitivity and specificity of dual-source CT to detect and rule out significant CAD in patients presenting with uncontrolled hypertension accompanied by chest pain. 260 consecutive patients presenting with acute chest pain in the context of stage 2 hypertension (systolic pressure ≥160 and/or diastolic pressure ≥100) were enrolled in the study. After admission, control of blood pressure and risk stratification, 82 patients were excluded due to renal insufficiency, prior coronary revascularisation or refused participation in the study. 90 further patients with low pre-test probability of CAD were also excluded. 88 remaining patients were subjected to CT coronary angiography using dual-source CT (Definition, Siemens Medical Solutions, Forchheim, Germany) within 24 h before invasive coronary angiography. A contrast-enhanced volume dataset was acquired (120 kV, 400 mAs/rot, collimation 2 × 64 × 0.6 mm, retrospective ECG gating). Data sets were evaluated concerning the presence or absence of significant coronary stenoses and validated against invasive coronary angiography. A significant stenosis was assumed if the diameter reduction was ≥50%. 88 patients (mean age 66 ± 11 years, mean heart rate 61 ± 9 bpm) were evaluated regarding the presence or absence of significant CAD (at least one stenosis ≥50% diameter reduction). Mean systolic blood pressure on presentation was 203 ± 20 mmHg and mean diastolic blood pressure was 103 ± 13 mmHg. On a per patient basis, the sensitivity and specificity for dual-source CT to detect significant CAD in vessels >1.5 mm diameter was 100% (36/36, 95% CI 90-100) and 90% (47/52, 95% CI 79-97), respectively with a negative predictive value (NPV) of 100% (47/47, 95% CI 92-100) and a

  20. Detection and characterization of crystal suspensions using single-source dual-energy computed tomography: a phantom model of crystal arthropathies.

    PubMed

    Diekhoff, Torsten; Kiefer, Tobias; Stroux, Andrea; Pilhofer, Irid; Juran, Ralf; Mews, Jürgen; Blobel, Jörg; Tsuyuki, Masaharu; Ackermann, Beate; Hamm, Bernd; Hermann, Kay-Geert A

    2015-04-01

    The aim of this study was to perform phantom measurements to prove the feasibility of single-source dual-energy computed tomography (DECT) of the extremities using a volume scan mode. In addition, we, for the first time, wanted to determine which concentrations of monosodium urate (MSU) in gout and calcium pyrophosphate (CP) in pseudogout are needed to detect or distinguish these soft tissue depositions with DECT. We created a hand-shaped plastic phantom assembled with a descending order of concentrations of MSU (6.25%-50%) and CP (1.56%-50%) with similar attenuation in conventional computed tomographic (CT) images. Dual-energy imaging was done on a standard 320-row CT scanner with acquisition of 2 volumes: one at 80 and the other at 135 kV. Using linear regression analysis, dual-energy gradients were calculated for MSU and CP. Thereafter, we selected a specific region of interest on the dual-energy graph to color-code MSU and CP on the images. Three blinded readers scored 10 scans of the randomly equipped phantom, corresponding to 60 samples, to determine the sensitivity and specificity of this technique. Receiver operating characteristics analysis was done to determine the diagnostic power. We found a dual-energy gradient for MSU of 1.020 ± 0.006 and for CP of 0.673 ± 0.001. Assessment of the randomized phantom scans indicates reliable detection of MSU at concentrations of 12.5 % or higher and that of CP at 6.25 % or higher, corresponding to deposits with mean Hounsfield unit values of 59.8 for MSU and 101.1 for CP. The sensitivity for MSU ranged from 83.3% to 97.3% at 15/90 mA (135/80 kV) and from 86.7% to 97.3% at 100/570 mA. Specificity was 96.7% to 100% in 15/90 mA and 100% in 100/570 mA of scans. However, there was inferior sensitivity for CP owing to lower concentrations. In the receiver operating characteristics analysis, the area under the curve for MSU ranged from 0.867 to 0.947 at 15/90 mA and from 0.867 to 0.919 at 100/570 mA and that for CP from 0

  1. A planar, chip-based, dual-beam refractometer using an integrated organic light-emitting diode (OLED) light source and organic photovoltaic (OPV) detectors.

    PubMed

    Ratcliff, Erin L; Veneman, P Alex; Simmonds, Adam; Zacher, Brian; Huebner, Daniel; Saavedra, S Scott; Armstrong, Neal R

    2010-04-01

    We present a simple chip-based refractometer with a central organic light-emitting diode (OLED) light source and two opposed organic photovoltaic (OPV) detectors on an internal reflection element (IRE) substrate, creating a true dual-beam sensor platform. For first-generation platforms, we demonstrate the use of a single heterojunction OLED based on electroluminescence from an Alq(3)/TPD heterojunction (tris-(8-hydroxyquinoline)aluminum/N,N'-bis(3-methylphenyl)-N,N'-diphenylbenzidine) and light detection with planar heterojunction pentacene/C(60) OPVs. The sensor utilizes the considerable fraction of emitted light from conventional thin-film OLEDs that is coupled into guided modes in the IRE, instead of into the forward (display) direction. A ray-optics description is used to describe light throughput and efficiency-limiting factors for light coupling from the OLED into the substrate modes, light traversing through the IRE substrate, and light coupling into the OPV detectors. The arrangement of the OLED at the center of the chip provides for two sensing regions: a "sample" channel and a "reference" channel, with detection of light by independent OPV detectors. This configuration allows for normalization of the sensor response against fluctuations in OLED light output, stability, and local fluctuations (temperature) that might influence sensor response. The dual-beam configuration permits significantly enhanced sensitivity to refractive index changes, relative to single-beam protocols, and is easily integrated into a field-portable instrumentation package. Changes in refractive index (DeltaRI) between 10(-2) and 10(-3) RI units could be detected for single beam operation, with sensitivity increased to DeltaRI approximately 10(-4) RI units when the dual-beam configuration is employed.

  2. A Planar, Chip-Based, Dual-Beam Refractometer Using an Integrated Organic Light Emitting Diode (OLED) Light Source and Organic Photovoltaic (OPV) Detectors

    PubMed Central

    Ratcliff, Erin L.; Veneman, P. Alex; Simmonds, Adam; Zacher, Brian; Huebner, Daniel

    2010-01-01

    We present a simple chip-based refractometer with a central organic light emitting diode (OLED) light source and two opposed organic photovoltaic (OPV) detectors on an internal reflection element (IRE) substrate, creating a true dual-beam sensor platform. For first-generation platforms, we demonstrate the use of a single heterojunction OLED based on electroluminescence emission from an Alq3/TPD heterojunction (tris-(8-hydroxyquinoline)aluminum/N,N′-Bis(3-methylphenyl)-N,N′-diphenylbenzidine) and light detection with planar heterojunction pentacene/C60 OPVs. The sensor utilizes the considerable fraction of emitted light from conventional thin film OLEDs that is coupled into guided modes in the IRE instead of into the forward (display) direction. A ray-optics description is used to describe light throughput and efficiency-limiting factors for light coupling from the OLED into the substrate modes, light traversing through the IRE substrate, and light coupling into the OPV detectors. The arrangement of the OLED at the center of the chip provides for two sensing regions, a “sample” and “reference” channel, with detection of light by independent OPV detectors. This configuration allows for normalization of the sensor response against fluctuations in OLED light output, stability, and local fluctuations (temperature) which might influence sensor response. The dual beam configuration permits significantly enhanced sensitivity to refractive index changes relative to single-beam protocols, and is easily integrated into a field-portable instrumentation package. Changes in refractive index (ΔR.I.) between 10−2 and 10−3 R.I. units could be detected for single channel operation, with sensitivity increased to ΔR.I. ≈ 10−4 units when the dual beam configuration is employed. PMID:20218580

  3. Image quality and radiation dose of lower extremity CT angiography at 70 kVp on an integrated circuit detector dual-source computed tomography.

    PubMed

    Qi, Li; Zhao, Yan'E; Zhou, Chang Sheng; Spearman, James V; Renker, Matthias; Schoepf, U Joseph; Zhang, Long Jiang; Lu, Guang Ming

    2015-06-01

    Despite the well-established requirement for radiation dose reduction there are few studies examining the potential for lower extremity CT angiography (CTA) at 70 kVp. To compare the image quality and radiation dose of lower extremity CTA at 70 kVp using a dual-source CT system with an integrated circuit detector to similar studies at 120 kVp. A total of 62 patients underwent lower extremity CTA. Thirty-one patients were examined at 70 kVp using a second generation dual-source CT with an integrated circuit detector (70 kVp group) and 31 patients were evaluated at 120 kVp using a first generation dual-source CT (120 kVp group). The attenuation and image noise were measured and signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Two radiologists assessed image quality. Radiation dose was compared. The mean attenuation of the 70 kVp group was higher than the 120 kVp group (575 ± 149 Hounsfield units [HU] vs. 258 ± 38 HU, respectively, P < 0.001) as was SNR (44.0 ± 22.0 vs 32.7 ± 13.3, respectively, P = 0.017), CNR (39.7 ± 20.6 vs 26.6 ± 11.7, respectively, P = 0.003) and the mean image quality score (3.7 ± 0.1 vs. 3.2 ± 0.3, respectively, P < 0.001). The inter-observer agreement was good for the 70 kVp group and moderate for the 120 kVp group. The dose-length product was lower in the 70 kVp group (264.5 ± 63.1 mGy × cm vs. 412.4 ± 81.5 mGy × cm, P < 0.001). Lower extremity CTA at 70 kVp allows for lower radiation dose with higher SNR, CNR, and image quality when compared with standard 120 kVp. © The Foundation Acta Radiologica 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  4. SU-D-207-03: Development of 4D-CBCT Imaging System with Dual Source KV X-Ray Tubes

    SciTech Connect

    Nakamura, M; Ishihara, Y; Matsuo, Y; Ueki, N; Iizuka, Y; Mizowaki, T; Hiraoka, M

    2015-06-15

    Purpose: The purposes of this work are to develop 4D-CBCT imaging system with orthogonal dual source kV X-ray tubes, and to determine the imaging doses from 4D-CBCT scans. Methods: Dual source kV X-ray tubes were used for the 4D-CBCT imaging. The maximum CBCT field of view was 200 mm in diameter and 150 mm in length, and the imaging parameters were 110 kV, 160 mA and 5 ms. The rotational angle was 105°, the rotational speed of the gantry was 1.5°/s, the gantry rotation time was 70 s, and the image acquisition interval was 0.3°. The observed amplitude of infrared marker motion during respiration was used to sort each image into eight respiratory phase bins. The EGSnrc/BEAMnrc and EGSnrc/DOSXYZnrc packages were used to simulate kV X-ray dose distributions of 4D-CBCT imaging. The kV X-ray dose distributions were calculated for 9 lung cancer patients based on the planning CT images with dose calculation grid size of 2.5 x 2.5 x 2.5 mm. The dose covering a 2-cc volume of skin (D2cc), defined as the inner 5 mm of the skin surface with the exception of bone structure, was assessed. Results: A moving object was well identified on 4D-CBCT images in a phantom study. Given a gantry rotational angle of 105° and the configuration of kV X-ray imaging subsystems, both kV X-ray fields overlapped at a part of skin surface. The D2cc for the 4D-CBCT scans was in the range 73.8–105.4 mGy. Linear correlation coefficient between the 1000 minus averaged SSD during CBCT scanning and D2cc was −0.65 (with a slope of −0.17) for the 4D-CBCT scans. Conclusion: We have developed 4D-CBCT imaging system with dual source kV X-ray tubes. The total imaging dose with 4D-CBCT scans was up to 105.4 mGy.

  5. Multiparametric Evaluation of Head and Neck Squamous Cell Carcinoma Using a Single-Source Dual-Energy CT with Fast kVp Switching: State of the Art.

    PubMed

    Lam, Stephanie; Gupta, Rajiv; Kelly, Hillary; Curtin, Hugh D; Forghani, Reza

    2015-11-06

    There is an increasing body of evidence establishing the advantages of dual-energy CT (DECT) for evaluation of head and neck squamous cell carcinoma (HNSCC). Focusing on a single-source DECT system with fast kVp switching, we will review the principles behind DECT and associated post-processing steps that make this technology especially suitable for HNSCC evaluation and staging. The article will review current applications of DECT for evaluation of HNSCC including use of different reconstructions to improve tumor conspicuity, tumor-normal soft tissue interface, accuracy of invasion of critical structures such as thyroid cartilage, and reduce dental artifact. We will provide a practical approach for DECT implementation into routine clinical use and a multi-parametric approach for scan interpretation based on the experience at our institution. The article will conclude with a brief overview of potential future applications of the technique.

  6. Dual-frequency comb generation with differing GHz repetition rates by parallel Fabry-Perot cavity filtering of a single broadband frequency comb source

    NASA Astrophysics Data System (ADS)

    Mildner, Jutta; Meiners-Hagen, Karl; Pollinger, Florian

    2016-07-01

    We present a dual-comb-generator based on a coupled Fabry-Perot filtering cavity doublet and a single seed laser source. By filtering a commercial erbium-doped fiber-based optical frequency comb with CEO-stabilisation and 250 MHz repetition rate, two broadband coherent combs of different repetition rates in the GHz range are generated. The filtering doublet consists of two Fabry-Perot cavities with a tunable spacing and Pound-Drever-Hall stabilisation scheme. As a prerequisite for the development of such a filtering unit, we present a method to determine the actual free spectral range and transmission bandwidth of a Fabry-Perot cavity in situ. The transmitted beat signal of two diode lasers is measured as a function of their tunable frequency difference. Finally, the filtering performance and resulting beat signals of the heterodyned combs are discussed as well as the optimisation measures of the whole system.

  7. Adenosine stress high-pitch 128-slice dual-source myocardial computed tomography perfusion for imaging of reversible myocardial ischemia: comparison with magnetic resonance imaging.

    PubMed

    Feuchtner, Gudrun; Goetti, Robert; Plass, André; Wieser, Monika; Scheffel, Hans; Wyss, Christophe; Stolzmann, Paul; Donati, Olivio; Schnabl, Johannes; Falk, Volkmar; Alkadhi, Hatem; Leschka, Sebastian; Cury, Ricardo C

    2011-09-01

    Coronary computed tomography angiography (CTA) enables accurate anatomic evaluation of coronary artery stenosis but lacks information about hemodynamic significance. The aim of this study was to evaluate 128-slice myocardial CT perfusion (CTP) imaging with adenosine stress using a high-pitch mode, in comparison with cardiac MRI (CMR). Thirty-nine patients with intermediate to high coronary risk profile underwent adenosine stress 128-slice dual source CTP (128×0.6 mm, 0.28 seconds). Among those, 30 patients (64 ± 10 years, 6% women) also underwent adenosine stress CMR (1.5T). The 2-step CTP protocol consisted of (1) adenosine stress-CTP using a high-pitch factor (3.4) ECG-synchronized spiral mode and (2) rest-CTP/coronary-CTA using either high-pitch (heart rate <63 bpm) or prospective ECG-triggering (heart rate >63 bpm). Results were compared with CMR and with invasive angiography in 25 patients. The performance of stress-CTP for detection of myocardial perfusion defects compared with CMR was sensitivity, 96%; specificity, 88%; positive predictive value (PPV), 93%; negative predictive value (NPV), 94% (per vessel); and sensitivity, 78%; specificity, 87%; PPV, 83%; NPV, 84% (per segment). The accuracy of stress-CTP for imaging of reversible ischemia compared with CMR was sensitivity, 95%; specificity, 96%; PPV, 95%; and NPV, 96% (per vessel). In 25 patients who underwent invasive angiography, the accuracy of CTA for detection of stenosis >70% was (per segment): sensitivity, 96%; specificity, 88%; PPV, 67%; and NPV, 98.9%. The accuracy improved from 84% to 95% after adding stress CTP to CTA. Radiation exposure of the entire stress/rest CT protocol was only 2.5 mSv. Adenosine-induced stress 128-slice dual-source high-pitch myocardial CTP allows for simultaneously assessment of reversible myocardial ischemia and coronary stenosis, with good diagnostic accuracy as compared with CMR and invasive angiography, at a very low radiation exposure.

  8. Multicenter Evaluation Of Coronary Dual-Source CT angiography in patients with intermediate Risk of Coronary Artery Stenoses (MEDIC): study design and rationale.

    PubMed

    Marwan, Mohamed; Hausleiter, Jörg; Abbara, Suhny; Hoffmann, Udo; Becker, Christoph; Ovrehus, Kristian; Ropers, Dieter; Bathina, Ravi; Berman, Dan; Anders, Katharina; Uder, Michael; Meave, Aloha; Alexánderson, Erick; Achenbach, Stephan

    2014-01-01

    The diagnostic performance of multidetector row CT to detect coronary artery stenosis has been evaluated in numerous single-center studies, with only limited data from large cohorts with low-to-intermediate likelihood of coronary disease and in multicenter trials. The Multicenter Evaluation of Coronary Dual-Source CT Angiography in Patients with Intermediate Risk of Coronary Artery Stenoses (MEDIC) trial determines the accuracy of dual-source CT (DSCT) to identify persons with at least 1 coronary artery stenosis among patients with low-to-intermediate pretest likelihood of disease. The MEDIC trial was designed as a prospective, multicenter, international trial to evaluate the diagnostic performance of DSCT for the detection of coronary artery stenosis compared with invasive coronary angiography. The study includes 8 sites in Germany, India, Mexico, the United States, and Denmark. The study population comprises patients referred for a diagnostic coronary angiogram because of suspected coronary artery disease with an intermediate pretest likelihood as determined by sex, age, and symptoms. All evaluations are performed by blinded core laboratory readers. The primary outcome of the MEDIC trial is the accuracy of DSCT to identify the presence of coronary artery stenoses with a luminal diameter narrowing of 50% or more on a per-vessel basis. Secondary outcome parameters include per-patient and per-segment diagnostic accuracy for 50% stenoses and accuracy to identify stenoses of 70% or more. Furthermore, secondary outcome parameters include the influence of heart rate, Agatston score, body weight, body mass index, image quality, and diagnostic confidence on the accuracy to detect coronary artery stenoses >50% on a per-vessel basis. The results of the MEDIC trial will assess the clinical utility of coronary CT angiography in the evaluation of patients with intermediate pretest likelihood of coronary artery disease. Copyright © 2014 Society of Cardiovascular Computed

  9. In Vitro Comparison of Second- and Third-generation Dual-source CT for Coronary Stent Visualization at Different Tube Potentials.

    PubMed

    Gassenmaier, Tobias; Petri, Nils; Allmendinger, Thomas; Flohr, Thomas; Weng, Andreas M; Kunz, Andreas S; Petritsch, Bernhard; Voelker, Wolfram; Bley, Thorsten A

    2016-08-01

    The study aimed to evaluate in vitro stent lumen visibility of coronary stents in a second- and third-generation dual-source computed tomography (CT) system at 100 and 120 kVp tube potential. Twenty-six coronary stents ranging from 2.25 to 4.0 mm in diameter were implanted in a coronary vessel phantom. Scans were performed at 100 and 120 kVp tube potential. Evaluation was performed using a medium-sharp kernel in both systems (B46f in the second-generation and Bv49 in the third-generation model) and a sharp (Bv59) convolution kernel optimized for vascular imaging in the third-generation CT. The median visible stent lumen diameter in the second-generation system was higher at 120 kVp with a median of 62.0% compared to 56.3% at 100 kVp (P < 0.001). The median visible diameter in the third-generation system was significantly higher applying the Bv49 kernel with 66.7% at 120 kVp and 61.1% at 100 kVp (both P < 0.001). When applying the Bv59 kernel, visible stent lumen further increased to 69.3% at 120 kVp and 66.7% at 100 kVp. Additionally, stent lumen was assessed using full width at half maximum, resulting in a comparable increase in luminal diameter at corresponding tube potential. Third-generation dual-source CT provides superior stent lumen visibility at equivalent tube potential and at reduced tube potential of 100 kVp when compared to 120 kVp in a second-generation system, at least when manually assessed. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  10. Contrast volume reduction using third generation dual source computed tomography for the evaluation of patients prior to transcatheter aortic valve implantation.

    PubMed

    Bittner, Daniel O; Arnold, Martin; Klinghammer, Lutz; Schuhbaeck, Annika; Hell, Michaela M; Muschiol, Gerd; Gauss, Soeren; Lell, Michael; Uder, Michael; Hoffmann, Udo; Achenbach, Stephan; Marwan, Mohamed

    2016-12-01

    Chronic renal failure is common in patients referred for transcatheter aortic valve implantation (TAVI). CT angiography is recommended and provides crucial information prior to TAVI. We evaluated the feasibility of a reduced contrast volume protocol for pre-procedural CT imaging. Forty consecutive patients were examined with prospectively ECG-triggered high-pitch spiral acquisition using a novel third-generation dual-source CT system; 38 ml contrast agent was used. Image quality was graded on a visual scale (1-4). Contrast attenuation was measured at the level of the aortic root and at the iliac bifurcation. Mean patient age was 82 ± 6 years (23 males; 58 %). Mean attenuation/average image quality was 285 ± 60 HU/1.5 at the aortic annulus compared to 289 ± 74 HU/1.8 at the iliac bifurcation (p = 0.77/p = 0.29). Mean estimated effective radiation dose was 2.9 ± 0.3 mSv. A repeat acquisition was necessary in one patient due to image quality. Out of the 35 patients who underwent TAVI, 31 (89 %) patients had no or mild aortic regurgitation. Thirty-two (91 %) patients were discharged successfully. Pre-procedural CTA with a total of 38 ml contrast volume is feasible and clinically useful, using third-generation dual-source CT, allowing comprehensive imaging for procedural success. • Reduction of contrast agent volume is crucial in patients with chronic renal failure. • Novel third-generation computed tomography helps to reduce contrast agent volume. • Pre-procedural CT allows comprehensive imaging for procedural success before heart valve implantation. • A low-contrast CT protocol is feasible for pre-procedural TAVI planning.

  11. A high performance Ge/Si0.5Ge0.5/Si heterojunction dual sources tunneling transistor with a U-shaped channel

    NASA Astrophysics Data System (ADS)

    Li, Wei; Liu, Hongxia; Wang, Shulong; Wang, Qianqiong; Chen, Shupeng

    2017-06-01

    In this paper, a new Ge/Si0.5Ge0.5/Si heterojunction dual sources tunneling transistor with a U-shaped channel (Ge_DUTFET) is proposed and investigated by Silvaco-Atlas simulation. The line tunneling perpendicular to channel and point tunneling parallel to channel simultaneously occur on both sides of the gate. The Ge is chosen as the source region material to increase the line tunneling current. The designed heterojunction between the Ge source and Si channel decreases the point tunneling barrier width to enhance the point tunneling current. And this heterojunction can also promote the Ge_DUTFET to occur point tunneling at the small gate voltage, which makes it obtain the smaller turn-on voltage. Furthermore, the Si0.5Ge0.5 buffer layer is also helpful for the enhancement of performance. The simulation results reveal that Ge_DUTFET has the better performance compared with the Si_DUTFET. The on-state current and average subthreshold swing of Ge_DUTFET are 1.11 × 10-5A/μm and 35.1mV/dec respectively. The max cut-off frequency (fT) and gain bandwidth product (GBW) are 26.6 GHz and 16.6 GHz respectively. The fT and GBW of the Ge_DUTFET are respectively increased by ∼27.4% and ∼84.3% compared with the Si_DUTFET.

  12. Power combination of two phase-locked high power microwave beams from a new coaxial microwave source based on dual beams

    SciTech Connect

    Li, Yangmei; Zhang, Xiaoping Zhang, Jiande; Dang, Fangchao; Yan, Xiaolu

    2014-10-15

    The new coaxial high power microwave source based on dual beams has demonstrated two phase-locked output microwave beams generated by its two sub-sources. In order to achieve a single higher output power, we present a three-port waveguide-based power combiner to combine the two microwave beams. Particle-in-cell simulation results show that when the diode voltage is 675 kV and the guiding magnetic field is 0.8 T, a combined microwave with an average power of about 4.0 GW and a frequency of 9.74 GHz is generated; the corresponding power conversion efficiency is 29%. The combination effect of the combiner is further validated in the diode voltage range from 675 kV to 755 kV as well as in the pulse regime. The simulations indicate that the maximum surface axial electric field strength of the electrodynamic structure is 720 kV/cm, which is relatively low corresponding to an output power of 4.0 GW. The stable combined output suggests the probability of long-pulse operation for the combined source.

  13. A dual-channel, curved-crystal spectrograph for petawatt laser, x-ray backlighter source studies.

    PubMed

    Theobald, W; Stoeckl, C; Jaanimagi, P A; Nilson, P M; Storm, M; Meyerhofer, D D; Sangster, T C; Hey, D; MacKinnon, A J; Park, H-S; Patel, P K; Shepherd, R; Snavely, R A; Key, M H; King, J A; Zhang, B; Stephens, R B; Akli, K U; Highbarger, K; Daskalova, R L; Van Woerkom, L; Freeman, R R; Green, J S; Gregori, G; Lancaster, K; Norreys, P A

    2009-08-01

    A dual-channel, curved-crystal spectrograph was designed to measure time-integrated x-ray spectra in the approximately 1.5 to 2 keV range (6.2-8.2 A wavelength) from small-mass, thin-foil targets irradiated by the VULCAN petawatt laser focused up to 4x10(20) W/cm(2). The spectrograph consists of two cylindrically curved potassium-acid-phthalate crystals bent in the meridional plane to increase the spectral range by a factor of approximately 10 compared to a flat crystal. The device acquires single-shot x-ray spectra with good signal-to-background ratios in the hard x-ray background environment of petawatt laser-plasma interactions. The peak spectral energies of the aluminum He(alpha) and Ly(alpha) resonance lines were approximately 1.8 and approximately 1.0 mJ/eV sr (approximately 0.4 and 0.25 J/A sr), respectively, for 220 J, 10 ps laser irradiation.

  14. A Dual-Channel, Curved-Crystal Spectrograph for Petawatt Laser, X-Ray Backlighter Source Studies

    SciTech Connect

    Theobald, W.; Stoeckl, C.; Jaanimagi, P.A.; Nilson, P.M.; Storm, M.; Meyerhofer, D.D.; Sangster, T.C.; Hey, D.; MacKinnon, A.J.; Park, H.-S.; Patel, P.K.; Shepherd, R.; Snavely, R.A.; Key, M.H.; King, J.A.; Zhang, B.; Stephens, R.B.; Akli, K.U.; Highbarger, K.; Daskalova, R.L.; VanWoerkom, L.; Freeman, R.R.; Green, J.S.; Gregori, G.; Lancaster, K.; Norreys, P.A.

    2009-08-19

    A dual-channel, curved-crystal spectrograph was designed to measure time-integrated x-ray spectra in the ~1.5 to 2 keV range (6.2–8.2 Å wavelength) from small-mass, thin-foil targets irradiated by the VULCAN petawatt laser focused up to 4 x 10^20 W/cm^2. The spectrograph consists of two cylindrically curved potassium-acid-phthalate crystals bent in the meridional plane to increase the spectral range by a factor of ~10 compared to a flat crystal. The device acquires single-shot x-ray spectra with good signal-to-background ratios in the hard x-ray background environment of petawatt laser-plasma interactions. The peak spectral energies of the aluminum He-alpha and Ly-alpha resonance lines were ~1.8 and ~1.0 mJ/eV sr (~0.4 and 0.25 J/Å sr), respectively, for 220 J, 10 ps laser irradiation.

  15. A dual-channel, curved-crystal spectrograph for petawatt laser, x-ray backlighter source studies

    SciTech Connect

    Theobald, W.; Stoeckl, C.; Jaanimagi, P. A.; Nilson, P. M.; Storm, M.; Meyerhofer, D. D.; Sangster, T. C.; Hey, D.; MacKinnon, A. J.; Park, H.-S.; Patel, P. K.; Shepherd, R.; Snavely, R. A.; Key, M. H.; King, J. A.; Zhang, B.; Stephens, R. B.; Akli, K. U.; Highbarger, K.; Daskalova, R. L.; and others

    2009-08-15

    A dual-channel, curved-crystal spectrograph was designed to measure time-integrated x-ray spectra in the {approx}1.5 to 2 keV range (6.2-8.2 A wavelength) from small-mass, thin-foil targets irradiated by the VULCAN petawatt laser focused up to 4x10{sup 20} W/cm{sup 2}. The spectrograph consists of two cylindrically curved potassium-acid-phthalate crystals bent in the meridional plane to increase the spectral range by a factor of {approx}10 compared to a flat crystal. The device acquires single-shot x-ray spectra with good signal-to-background ratios in the hard x-ray background environment of petawatt laser-plasma interactions. The peak spectral energies of the aluminum He{sub {alpha}} and Ly{sub {alpha}} resonance lines were {approx}1.8 and {approx}1.0 mJ/eV sr ({approx}0.4 and 0.25 J/A sr), respectively, for 220 J, 10 ps laser irradiation.

  16. Dual-energy imaging of bone marrow edema on a dedicated multi-source cone-beam CT system for the extremities

    NASA Astrophysics Data System (ADS)

    Zbijewski, W.; Sisniega, A.; Stayman, J. W.; Thawait, G.; Packard, N.; Yorkston, J.; Demehri, S.; Fritz, J.; Siewerdsen, J. H.

    2015-03-01

    Purpose: Arthritis and bone trauma are often accompanied by bone marrow edema (BME). BME is challenging to detect in CT due to the overlaying trabecular structure but can be visualized using dual-energy (DE) techniques to discriminate water and fat. We investigate the feasibility of DE imaging of BME on a dedicated flat-panel detector (FPD) extremities cone-beam CT (CBCT) with a unique x-ray tube with three longitudinally mounted sources. Methods: Simulations involved a digital BME knee phantom imaged with a 60 kVp low-energy beam (LE) and 105 kVp high-energy beam (HE) (+0.25 mm Ag filter). Experiments were also performed on a test-bench with a Varian 4030CB FPD using the same beam energies as the simulation study. A three-source configuration was implemented with x-ray sources distributed along the longitudinal axis and DE CBCT acquisition in which the superior and inferior sources operate at HE (and collect half of the projection angles each) and the central source operates at LE. Three-source DE CBCT was compared to a double-scan, single-source orbit. Experiments were performed with a wrist phantom containing a 50 mg/ml densitometry insert submerged in alcohol (simulating fat) with drilled trabeculae down to ~1 mm to emulate the trabecular matrix. Reconstruction-based three-material decomposition of fat, soft tissue, and bone was performed. Results: For a low-dose scan (36 mAs in the HE and LE data), DE CBCT achieved combined accuracy of ~0.80 for a pattern of BME spherical lesions ranging 2.5 - 10 mm diameter in the knee phantom. The accuracy increased to ~0.90 for a 360 mAs scan. Excellent DE discrimination of the base materials was achieved in the experiments. Approximately 80% of the alcohol (fat) voxels in the trabecular phantom was properly identified both for single and 3-source acquisitions, indicating the ability to detect edemous tissue (water-equivalent plastic in the body of the densitometry insert) from the fat inside the trabecular matrix

  17. Dual-wavelength source from 5%MgO:PPLN cylinders for the characterization of nonlinear infrared crystals.

    PubMed

    Kemlin, Vincent; Jegouso, David; Debray, Jérôme; Boursier, Elodie; Segonds, Patricia; Boulanger, Benoit; Ishizuki, Hideki; Taira, Takunori; Mennerat, Gabriel; Melkonian, Jean-Michel; Godard, Antoine

    2013-11-18

    We conceived a unique fully parametric source based on two independent cylindrical OPOs simultaneously pumped by the same Nd:YAG laser. Each OPO delivers more than 2 mJ and is continuously tunable between 1.41 µm and 4.3 µm. This source is of particular interest for the study of the generation of infrared parametric light in nonlinear crystals. It was validated by performing difference frequency generation experiments in CdSe crystals with output in the range 8 - 10 µm.

  18. A Description of Analysis for the Identification of Potential Sources of Bias in Dual Language Achievement Tests.

    ERIC Educational Resources Information Center

    Cabello, Beverly

    1983-01-01

    Although the vocabulary, content, and format of the English and Spanish versions of the California Test of Basic Skills were largely equivalent, content analysis revealed three possible sources of test bias: (1) problems inherent in translation; (2) the match between tests and instructional materials; and (3) intervening cultural variables. (SB)

  19. Quantitative identification of nitrate pollution sources and uncertainty analysis based on dual isotope approach in an agricultural watershed.

    PubMed

    Ji, Xiaoliang; Xie, Runting; Hao, Yun; Lu, Jun

    2017-10-01

    Quantitative identification of nitrate (NO3(-)-N) sources is critical to the control of nonpoint source nitrogen pollution in an agricultural watershed. Combined with water quality monitoring, we adopted the environmental isotope (δD-H2O, δ(18)O-H2O, δ(15)N-NO3(-), and δ(18)O-NO3(-)) analysis and the Markov Chain Monte Carlo (MCMC) mixing model to determine the proportions of riverine NO3(-)-N inputs from four potential NO3(-)-N sources, namely, atmospheric deposition (AD), chemical nitrogen fertilizer (NF), soil nitrogen (SN), and manure and sewage (M&S), in the ChangLe River watershed of eastern China. Results showed that NO3(-)-N was the main form of nitrogen in this watershed, accounting for approximately 74% of the total nitrogen concentration. A strong hydraulic interaction existed between the surface and groundwater for NO3(-)-N pollution. The variations of the isotopic composition in NO3(-)-N suggested that microbial nitrification was the dominant nitrogen transformation process in surface water, whereas significant denitrification was observed in groundwater. MCMC mixing model outputs revealed that M&S was the predominant contributor to riverine NO3(-)-N pollution (contributing 41.8% on average), followed by SN (34.0%), NF (21.9%), and AD (2.3%) sources. Finally, we constructed an uncertainty index, UI90, to quantitatively characterize the uncertainties inherent in NO3(-)-N source apportionment and discussed the reasons behind the uncertainties. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Compact high-repetition-rate terahertz source based on difference frequency generation from an efficient 2-μm dual-wavelength KTP OPO

    NASA Astrophysics Data System (ADS)

    Mei, Jialin; Zhong, Kai; Wang, Maorong; Liu, Pengxiang; Xu, Degang; Wang, Yuye; Shi, Wei; Yao, Jianquan; Norwood, Robert A.; Peyghambarian, Nasser

    2016-11-01

    A compact optical terahertz (THz) source was demonstrated based on an efficient high-repetition-rate doubly resonant optical parametric oscillator (OPO) around 2 μm with two type-II phase-matched KTP crystals in the walk-off compensated configuration. The KTP OPO was intracavity pumped by an acousto-optical (AO) Q-switched Nd:YVO4 laser and emitted two tunable wavelengths near degeneracy. The tuning range extended continuously from 2.068 μm to 2.191 μm with a maximum output power of 3.29 W at 24 kHz, corresponding to an optical-optical conversion efficiency (from 808 nm to 2 μm) of 20.69%. The stable pulsed dual-wavelength operation provided an ideal pump source for generating terahertz wave of micro-watt level by the difference frequency generation (DFG) method. A 7.84-mm-long periodically inverted quasi-phase-matched (QPM) GaAs crystal with 6 periods was used to generate a terahertz wave, the maximum voltage of 180 mV at 1.244 THz was acquired by a 4.2-K Si bolometer, corresponding to average output power of 0.6 μW and DFG conversion efficiency of 4.32×10-7. The acceptance bandwidth was found to be larger than 0.35 THz (FWHM). As to the 15-mm-long GaSe crystal used in the type-II collinear DFG, a tunable THz source ranging from 0.503 THz to 3.63 THz with the maximum output voltage of 268 mV at 1.65 THz had been achieved, and the corresponding average output power and DFG conversion efficiency were 0.9 μW and 5.86×10-7 respectively. This provides a potential practical palm-top tunable THz sources for portable applications.

  1. Implementation and performance of SIBYLS: a dual endstation small-angle X-ray scattering and macromolecular crystallography beamline at the Advanced Light Source

    PubMed Central

    Classen, Scott; Hura, Greg L.; Holton, James M.; Rambo, Robert P.; Rodic, Ivan; McGuire, Patrick J.; Dyer, Kevin; Hammel, Michal; Meigs, George; Frankel, Kenneth A.; Tainer, John A.

    2013-01-01

    The SIBYLS beamline (12.3.1) of the Advanced Light Source at Lawrence Berkeley National Laboratory, supported by the US Department of Energy and the National Institutes of Health, is optimized for both small-angle X-ray scattering (SAXS) and macromolecular crystallography (MX), making it unique among the world’s mostly SAXS or MX dedicated beamlines. Since SIBYLS was commissioned, assessments of the limitations and advantages of a combined SAXS and MX beamline have suggested new strategies for integration and optimal data collection methods and have led to additional hardware and software enhancements. Features described include a dual mode monochromator [containing both Si(111) crystals and Mo/B4C multilayer elements], rapid beamline optics conversion between SAXS and MX modes, active beam stabilization, sample-loading robotics, and mail-in and remote data collection. These features allow users to gain valuable insights from both dynamic solution scattering and high-resolution atomic diffraction experiments performed at a single synchrotron beamline. Key practical issues considered for data collection and analysis include radiation damage, structural ensembles, alternative conformers and flexibility. SIBYLS develops and applies efficient combined MX and SAXS methods that deliver high-impact results by providing robust cost-effective routes to connect structures to biology and by performing experiments that aid beamline designs for next generation light sources. PMID:23396808

  2. Bilateral breast MRI by use of dual-source parallel radiofrequency excitation and image-based shimming at 3 Tesla: improvement in homogeneity on fat-suppression imaging.

    PubMed

    Ishizaka, Kinya; Kato, Fumi; Terae, Satoshi; Mito, Suzuko; Oyama-Manabe, Noriko; Kamishima, Tamotsu; Nakanishi, Mitsuhiro; Sugimori, Hiroyuki; Hamaguchi, Hiroyuki; Shirato, Hiroki

    2015-01-01

    In this study, we aimed to compare fat-suppression homogeneity on breast MR imaging by using dual-source parallel radiofrequency excitation and image-based shimming (DS-IBS) with single-source radiofrequency excitation with volume shim (SS-Vol) at 3 Tesla. Twenty patients were included. Axial three-dimensional T1-weighted turbo-field-echo breast images with DS-IBS and SS-Vol were obtained. Fat suppression was scored with four grade points. The contrast of the pectoral muscle and the fat in each breast area was obtained in the head medial, head lateral, foot medial, and foot lateral areas. The axillary space was calculated and compared between DS-IBS and SS-Vol. The average DS-IBS score was significantly higher than that of SS-Vol. The mean contrasts of fat in the foot lateral areas and axillary spaces on DS-IBS images were significantly higher than on SS-Vol images.

  3. A dual-inexact fuzzy stochastic model for water resources management and non-point source pollution mitigation under multiple uncertainties

    NASA Astrophysics Data System (ADS)

    Dong, C.; Tan, Q.; Huang, G.-H.; Cai, Y.-P.

    2014-01-01

    In this research, a dual-inexact fuzzy stochastic programming (DIFSP) method was developed for supporting the planning of water and farmland use management system considering the non-point source pollution mitigation under uncertainty. The random boundary interval (RBI) was incorporated into DIFSP through integrating fuzzy programming (FP) and chance-constrained programming (CCP) approaches within an interval linear programming (ILP) framework. The lower and upper bounds of RBI are continuous random variables, and the correlation exiting between the lower and upper bounds can be tackled in RBI through the joint probability distribution function. And thus the subjectivity of decision making is greatly reduced, enhancing the stability and robustness of obtained solutions. The proposed method was then applied to solve a water and farmland use planning model (WFUPM) with non-point source pollution. The generated results could provide decision makers with detailed water supply-demand schemes involving diversified water related activities under various system conditions. These useful solutions could allow more in-depth analyses of the trade-offs between human and environment, as well as those between system optimality and reliability. In addition, comparative analyses on the solutions obtained from ICCP (Interval chance-constraints programming) and DIFSP demonstrated the higher application of this developed approach for supporting the water and farmland use system planning.

  4. A dual-inexact fuzzy stochastic model for water resources management and non-point source pollution mitigation under multiple uncertainties

    NASA Astrophysics Data System (ADS)

    Dong, C.; Tan, Q.; Huang, G.-H.; Cai, Y.-P.

    2014-05-01

    In this research, a dual-inexact fuzzy stochastic programming (DIFSP) method was developed for supporting the planning of water and farmland use management system considering the non-point source pollution mitigation under uncertainty. The random boundary interval (RBI) was incorporated into DIFSP through integrating fuzzy linear programming (FLP) and chance-constrained programming (CCP) approaches within an interval linear programming (ILP) framework. This developed method could effectively tackle the uncertainties expressed as intervals and fuzzy sets. Moreover, the lower and upper bounds of RBI are continuous random variables, and the correlation existing between the lower and upper bounds can be tackled in RBI through the joint probability distribution function. And thus the subjectivity of decision making is greatly reduced, enhancing the stability and robustness of obtained solutions. The proposed method was then applied to solve a water and farmland use planning model (WFUPM) with non-point source pollution mitigation. The generated results could provide decision makers with detailed water supply-demand schemes involving diversified water-related activities under preferred satisfaction degrees. These useful solutions could allow more in-depth analyses of the trade-offs between humans and environment, as well as those between system optimality and reliability. In addition, comparative analyses on the solutions obtained from ICCP (Interval chance-constraints programming) and DIFSP demonstrated the higher application of this developed approach for supporting the water and farmland use system planning.

  5. An increase of curdlan productivity by integration of carbon/nitrogen sources control and sequencing dual fed-batch fermentors operation.

    PubMed

    Zheng, Z Y; Jiang, Y; Zhan, X B; Ma, L W; Wu, J R; Zhang, L M; Lin, C C

    2014-01-01

    Curdlan is produced by Agrobacterium sp. ATCC 31749 under nitrogen-limited conditions not associated with cell growth. A novel curdlan production process was developed based on the different nutrient requirements for microbial cell growth and its efficiency was increased by integrating carbon/nitrogen sources control and sequencing dual fed-batch fermentors operation. By feeding ammonium solution to supply abundant nitrogen source and controlling pH in Fermentor I, cell growth was accelerated. High cell density of 29 g/L was attained. The culture broth in Fermentor I was then inoculated into sequencing Fermentor II which alleviated the high requirement for dissolved oxygen and accumulation of inhibitory metabolic by-products during curdlan production. Fermentor I promoted cell growth. Curdlan production started instantaneously in Fermentor II. By feeding nutrient solution with high carbon/nitrogen ratio and NaOH solution for pH adjustment, a feasible and optimal curdlan production process was formulated. The productivity, conversion efficiency and curdlan yield were achieved of 0.98 g/(L h), 57% (w) and 67 g/L, respectively. Such novel process can be scaled up for significant cost reduction at the industrial level.

  6. Land-use controls on sources and processing of nitrate in small watersheds: Insights from dual isotopic analysis

    USGS Publications Warehouse

    Barnes, R.T.; Raymond, P.A.

    2010-01-01

    Studies have repeatedly shown that agricultural and urban areas export considerably more nitrogen to streams than forested counterparts, yet it is difficult to identify and quantify nitrogen sources to streams due to complications associated with terrestrial and in-stream biogeochemical processes. In this study, we used the isotopic composition of nitrate (??15N-NO3- and ??18O- NO3-) in conjunction with a simple numerical model to examine the spatial and temporal variability of nitrate (NO3-) export across a land-use gradient and how agricultural and urban development affects net removal mechanisms. In an effort to isolate the effects of land use, we chose small headwater systems in close proximity to each other, limiting the variation in geology, surficial materials, and climate between sites. The ??15N and ??18Oof stream NO 3- varied significantly between urban, agricultural, and forested watersheds, indicating that nitrogen sources are the primary determinant of the ??15N-NO3-, while the ??18O-NO3- was found to reflect biogeochemical processes. The greatest NO3- concentrations corresponded with the highest stream ??15N-NO3- values due to the enriched nature of two dominant anthropogenic sources, septic and manure, within the urban and agricultural watersheds, respectively. On average, net removal of the available NO3- pool within urban and agricultural catchments was estimated at 45%. The variation in the estimated net removal of NO3- from developed watersheds was related to both drainage area and the availability of organic carbon. The determination of differentiated isotopic land-use signatures and dominant seasonal mechanisms illustrates the usefulness of this approach in examining the sources and processing of excess nitrogen within headwater catchments. ?? 2010 by the Ecological Society of America.

  7. Design and analysis of a dual-axis resonator fiber-optic gyroscope employing a single source.

    PubMed

    Pinnoji, Prerana Dabral; Nayak, Jagannath

    2013-08-01

    In this paper, design of a resonator fiber-optic gyroscope comprised of a single laser source and two optical fiber resonator rings is presented. A typical gyroscope measures angular rotation around a fixed axis, whereas the proposed design can sense simultaneous rotation about two orthogonal axes. Two variants of the design are proposed and analyzed using a mathematical model based on Jones matrix methodology.

  8. Distribution and source identification of dissolved sulfate by dual isotopes in waters of the Babu subterranean river basin, SW China.

    PubMed

    Ren, Kun; Pan, Xiaodong; Zeng, Jie; Jiao, Youjun

    2017-01-01

    Sulfur and oxygen isotopes were employed to identify SO4(2-) sources in surface water and groundwater in the Babu subterranean river basin (BSRB). Our study revealed SO4(2-) enrichment in the BSRB waters compared with adjacent areas. The SO4(2-) in some samples originated mainly from precipitation; in others, it was derived mainly from sulfide dissolution in coal seams or from gypsum dissolution. In the water at the subterranean river exit, 13% of SO4(2-) originated from precipitation, 40% from sulfide oxidation in coal seams, and 47% from gypsum dissolution.

  9. Utility of dual frequency hybrid source for plasma and radical generation in plasma enhanced chemical vapor deposition process

    NASA Astrophysics Data System (ADS)

    Shin, Kyung Sik; Bhusan Sahu, Bibhuti; Geon Han, Jeon; Hori, Masaru

    2015-07-01

    Looking into the aspect of material processing, this work evaluates alternative plasma concepts in SiH4/H2 plasmas to investigate the radical and plasma generation in the plasma enhanced chemical vapor deposition (PECVD) synthesis of nanocrystalline Si (nc-Si:H). Simultaneous measurements by vacuum ultraviolet absorption spectroscopy (VUVAS), optical emission spectroscopy (OES), and radio frequency (RF) compensated Langmuir probe (LP) reveal that RF/ultrahigh frequency (UHF) hybrid source can efficiently produce H radicals and plasmas that are accountable for nc-Si:H film synthesis. The efficacy of hybrid plasmas is also discussed.

  10. Analysis of Dual Rotating Rake Data from the NASA Glenn Advanced Noise Control Fan Duct with Artificial Sources

    NASA Technical Reports Server (NTRS)

    Dahl, Milo D.; Sutliff, Daniel L.

    2014-01-01

    The Rotating Rake mode measurement system was designed to measure acoustic duct modes generated by a fan stage. Initially, the mode amplitudes and phases were quantified from a single rake measurement at one axial location. To directly measure the modes propagating in both directions within a duct, a second rake was mounted to the rotating system with an offset in both the axial and the azimuthal directions. The rotating rake data analysis technique was then extended to include the data measured by the second rake. The analysis resulted in a set of circumferential mode levels at each of the two rake microphone locations. Radial basis functions were then least-squares fit to this data to obtain the radial mode amplitudes for the modes propagating in both directions within the duct. Validation experiments have been conducted using artificial acoustic sources. Results are shown for the measurement of the standing waves in the duct from sound generated by one and two acoustic sources that are separated into the component modes propagating in both directions within the duct. Measured reflection coefficients from the open end of the duct are compared to analytical predictions.

  11. [Linkage of large secondary and registry data sources with data of cohort studies : usage of a dual potential].

    PubMed

    Jacobs, Svenja; Stallmann, Christoph; Pigeot, Iris

    2015-08-01

    Cohort studies provide the best evidence of all epidemiological observational studies for the identification of causal relationships between risk factors and diseases. However, this design may lead to drawbacks that may affect the validity and reliability of the results. This follows in particular from systematic errors, such as selection bias or recall bias. One possibility to avoid or counteract some of these drawbacks is to link primary data from cohort studies with secondary and register data. The linkage of these data may also be used for mutual validations. Data that were previously linked with primary data within the context of cohort studies in Germany were obtained from statutory health insurances and pensions as well as data from the Federal Employment Agency and cancer registries. All these data have two features in common: First, they all cover detailed information about a large population and over a long period of time. Second, all sources are in principle able to provide data on an individual level such that an individual data linkage, e.g. with primary data, is possible. However, use and linkage of each of these data sources are restricted by several limitations. These have to be accounted for as well as numerous legal restrictions that exist in Germany to especially prevent the misuse of social data.

  12. Feasibility of low-concentration iodinated contrast medium with lower-tube-voltage dual-source CT aortography using iterative reconstruction: comparison with automatic exposure control CT aortography.

    PubMed

    Shin, Hee Jeong; Kim, Song Soo; Lee, Jae-Hwan; Park, Jae-Hyeong; Jeong, Jin-Ok; Jin, Seon Ah; Shin, Byung Seok; Shin, Kyung-Sook; Ahn, Moonsang

    2016-06-01

    To evaluate the feasibility of low-concentration contrast medium (CM) for vascular enhancement, image quality, and radiation dose on computed tomography aortography (CTA) using a combined low-tube-voltage and iterative reconstruction (IR) technique. Ninety subjects underwent dual-source CT (DSCT) operating in dual-source, high-pitch mode. DSCT scans were performed using both high-concentration CM (Group A, n = 50; Iomeprol 400) and low-concentration CM (Group B, n = 40; Iodixanol 270). Group A was scanned using a reference tube potential of 120 kVp and 120 reference mAs under automatic exposure control with IR. Group B was scanned using low-tube-voltage (80 or 100 kVp if body mass index ≥25 kg/m(2)) at a fixed current of 150 mAs, along with IR. Images of the two groups were compared regarding attenuation, image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), iodine load, and radiation dose in various locations of the CTA. In comparison between Group A and Group B, the average mean attenuation (454.73 ± 86.66 vs. 515.96 ± 101.55 HU), SNR (25.28 ± 4.34 vs. 31.29 ± 4.58), and CNR (21.83 ± 4.20 vs. 27.55 ± 4.81) on CTA in Group B showed significantly greater values and significantly lower image noise values (18.76 ± 2.19 vs. 17.48 ± 3.34) than those in Group A (all Ps < 0.05). Homogeneous contrast enhancement from the ascending thoracic aorta to the infrarenal abdominal aorta was significantly superior in Group B (P < 0.05). Low-concentration CM and a low-tube-voltage combination technique using IR is a feasible method, showing sufficient contrast enhancement and image quality.

  13. Application of 70 kV Third-generation High-pitch Dual-source Coronary CT Angiography in Patients with Different Body Mass Index.

    PubMed

    Yi, Yan; Cao, Jian; Lin, Lu; Kong, Lingyan; Jiang, Shu; Li, Xiao; Liu, Peijun; Wang, Ming; Wang, Man; Wang, Yun; Jin, Zhengyu; Wang, Yining

    2017-02-20

    Objective  To investigate the optimized range of body mass index (BMI) selection for patients undergoing 70 kV high-pitch dual-source coronary CT angiography (CCTA) on the third-generation dual-source CT (DSCT). Methods  Patients undergoing prospective high-pitch ultra-low contrast media (CM) CCTA on the third-generation DSCT using the automatic tube voltage selection at 70 kV were included and divided into three groups:group A,with BMI≤24 kg/m(2);group B,with 24 kg/m(2)0.05). Subjective image quality in group A(Z=2.91,P=0.004) and B(Z=2.27,P=0.021) were both significantly better than that in group C. Conclusion  The ultra-low tube voltage (70 kV) combined with ultra-low CM CCTA protocol on third-generation high-pitch DSCT may be better for patients with BMI<28 kg/m2 than those with BMI ≥28 kg/m(2) in China.

  14. From first to latest imaging technology: Revisiting the first mummy investigated with X-ray in 1896 by using dual-source computed tomography.

    PubMed

    Zesch, Stephanie; Panzer, Stephanie; Rosendahl, Wilfried; Nance, John W; Schönberg, Stefan O; Henzler, Thomas

    2016-01-01

    The aim of this study was to systematically reinvestigate the first human mummy that was ever analyzed with X-ray imaging in 1896, using dual-source computed tomography (DSCT) in order to compare the earliest and latest imaging technologies, to estimate preservation, age at death, sex, anatomical variants, paleopathological findings, mummification, embalming and wrapping of the child mummy from ancient Egypt. Radiocarbon dating was used to determine the mummy's age and to specify the child's living period in the Egyptian chronology. The ancient Egyptian child mummy is kept in the Senckenberg Museum of Natural History in Frankfurt am Main, Germany. An accelerator mass spectrometer (MICADAS) was used for radiocarbon dating. DSCT was performed using a 2 × 64 slice dual-source CT system (Siemens Healthineers, Forchheim, Germany). A thorough visual examination of the mummy, a systematic radiological evaluation of the DICOM datasets, and established methods in physical anthropology were applied to assess the bio-anthropological data and the post mortem treatment of the body. Radiocarbon dating yielded a calibrated age between 378 and 235 cal BC (95.4% confidence interval), corresponding with the beginning of the Ptolemaic period. The mummy was a male who was four to five years old at the time of death. Remnants of the brain and inner organs were preserved by the embalmers, which is regularly observed in ancient Egyptian child mummies. Skin tissue, inner organs, tendons and/or musculature, cartilage, nerves and vasculature could be identified on the DSCT dataset. The dental health of the child was excellent. Anatomical variants and pathological defects included a congenital Pectus excavatum deformity, hepatomegaly, Harris lines, and longitudinal clefts in the ventral cortices of both femora. Our results highlight the enormous progress achieved form earliest to latest imaging technology for advanced mummy research using the first human mummy investigated with X

  15. Dual functionality of triticale as a novel dietary source of prebiotics with antioxidant activity in fermented dairy products.

    PubMed

    Agil, Rania; Hosseinian, Farah

    2012-03-01

    The objectives of this study were to: (i) define the optimum concentration of triticale bran (TB) that can be incorporated in yogurt, (ii) evaluate the prebiotic effects of TB on microbial viability, pH and total titratable acidity (TTA) in yogurt across 28 days of cold storage, and (iii) measure the oxygen radical absorbance capacity (ORAC) of water-extractable polysaccharides (WEP) in TB. Lactobacillus bulgaricus and Streptococcus thermophilus were used as starter cultures. Lactobacillus acidophilus and Bifidobacterium lactis were used as probiotics. A concentration of 4% TB in yogurt was determined to be the maximum amount that could be added without causing synersis. By day 7, the number of bacteria greatly increased in yogurt samples containing TB and maintained higher viable bacteria counts at the end of the cold storage period, in comparison to controls (P ≤ 0.05). Confirming this data was the lower pH levels and higher TTA values of TB yogurt samples exhibited throughout 28 days (P ≤ 0.05). Polysaccharide extracts of TB exhibited strong antioxidant activity with an ORAC value of 33.86 ± 2.30 μmol trolox equivalents (TE)/g of bran. Results of this study suggest that TB may serve as a new prebiotic and antioxidant source for functional foods and nutraceutical applications.

  16. Assessing the sources and magnitude of diurnal nitrate variability in the San Joaquin River (California) with an in situ optical nitrate sensor and dual nitrate isotopes

    USGS Publications Warehouse

    Pellerin, B.A.; Downing, B.D.; Kendall, C.; Dahlgren, R.A.; Kraus, T.E.C.; Saraceno, J.; Spencer, R.G.M.; Bergamaschi, B.A.

    2009-01-01

    1. We investigated diurnal nitrate (NO3-) concentration variability in the San Joaquin River using an in situ optical NO3- sensor and discrete sampling during a 5-day summer period characterized by high algal productivity. Dual NO3- isotopes (??15NNO3 and ??18O NO3) and dissolved oxygen isotopes (??18O DO) were measured over 2 days to assess NO3- sources and biogeochemical controls over diurnal time-scales. 2. Concerted temporal patterns of dissolved oxygen (DO) concentrations and ??18ODO were consistent with photosynthesis, respiration and atmospheric O2 exchange, providing evidence of diurnal biological processes independent of river discharge. 3. Surface water NO3- concentrations varied by up to 22% over a single diurnal cycle and up to 31% over the 5-day study, but did not reveal concerted diurnal patterns at a frequency comparable to DO concentrations. The decoupling of ??15NNO3 and ??18ONO3 isotopes suggests that algal assimilation and denitrification are not major processes controlling diurnal NO3- variability in the San Joaquin River during the study. The lack of a clear explanation for NO 3- variability likely reflects a combination of riverine biological processes and time-varying physical transport of NO3- from upstream agricultural drains to the mainstem San Joaquin River. 4. The application of an in situ optical NO3- sensor along with discrete samples provides a view into the fine temporal structure of hydrochemical data and may allow for greater accuracy in pollution assessment. ?? 2008 Blackwell Publishing Ltd.

  17. Cancer Patient-Derived Circulating Microparticles Enhance Lung Metastasis in a Rat Model: Dual-Source CT, Cellular, and Molecular Studies.

    PubMed

    Ko, Sheung-Fat; Yip, Hon-Kan; Zhen, Yen-Yi; Lee, Chia-Chang; Li, Jung-Hui; Lee, Chen-Chang; Leu, Steve; Huang, Chung-Cheng; Ng, Shu-Hang; Lin, Jui-Wei

    2016-08-01

    This study aimed to test the hypothesis that lung cancer patient-derived circulating microparticles (LCC-MPs) enhance metastatic lung tumors in a rat model. The controls (n = 6) and LCC-MP-treated rats (n = 6) with N1S1-induced pulmonary metastatic hepatocellular carcinoma (HCC) underwent dual-source CT (DSCT) on days 10, 15, and 20. Cellular and molecular studies were performed subsequently. DSCT revealed slow progression of metastatic lung tumors in the controls. Compared with the controls, the LCC-MP-treated rats exhibited significantly more and larger metastatic tumors on days 15 and 20 on DSCT, enhanced angiogenesis with higher microvessel count (CD34+), more CXCR4+ and VEGF+ cells in immunohistofluorescence studies, and higher protein expression levels of eNOS, angiopoietin, vascular endothelial growth factor, and CD31 on western blotting (Mann-Whitney test, all P < 0.05). LCC-MPs can elicit oncogenic stimulation and accelerate metastatic HCC growth in rat lung as demonstrated on DSCT and enhanced tumoral angiogenesis as confirmed in cellular and molecular studies.

  18. Terahertz source at 9.4 THz based on a dual-wavelength infrared laser and quasi-phase matching in organic crystals OH1

    SciTech Connect

    Majkić, A. Zgonik, M.; Petelin, A.; Jazbinšek, M.; Ruiz, B.; Medrano, C.; Günter, P.

    2014-10-06

    We present a compact, room temperature, and narrowband terahertz source, based on difference-frequency generation in the organic nonlinear optical crystals OH1 (2-[3-(4-hydroxystyryl)-5,5-dimethylcyclohex-2-enylidene]malononitrile). The system employs a specific dual-wavelength infrared laser that emits coaxial, synchronous 10-ns pulses of similar energy and duration at wavelengths of 1064 nm and 1030 nm by using Nd:YAG and Yb:YAG crystals within the split laser cavity. The common part of the laser cavity comprises an acousto-optic Q-switch and an output coupler. The output is frequency-mixed in a stack of several OH1 crystals in a quasi-phase-matching configuration, which is determined on the basis of refractive index and absorption measurements in the 1–11 THz range. The system generates terahertz radiation in pulse trains with 1.0 μW average power and a near-Gaussian intensity profile.

  19. Terahertz source at 9.4 THz based on a dual-wavelength infrared laser and quasi-phase matching in organic crystals OH1

    NASA Astrophysics Data System (ADS)

    Majkić, A.; Zgonik, M.; Petelin, A.; Jazbinšek, M.; Ruiz, B.; Medrano, C.; Günter, P.

    2014-10-01

    We present a compact, room temperature, and narrowband terahertz source, based on difference-frequency generation in the organic nonlinear optical crystals OH1 (2-[3-(4-hydroxystyryl)-5,5-dimethylcyclohex-2-enylidene]malononitrile). The system employs a specific dual-wavelength infrared laser that emits coaxial, synchronous 10-ns pulses of similar energy and duration at wavelengths of 1064 nm and 1030 nm by using Nd:YAG and Yb:YAG crystals within the split laser cavity. The common part of the laser cavity comprises an acousto-optic Q-switch and an output coupler. The output is frequency-mixed in a stack of several OH1 crystals in a quasi-phase-matching configuration, which is determined on the basis of refractive index and absorption measurements in the 1-11 THz range. The system generates terahertz radiation in pulse trains with 1.0 μW average power and a near-Gaussian intensity profile.

  20. Assessing sources of nitrate contamination in the Shiraz urban aquifer (Iran) using the δ(15)N and δ(18)O dual-isotope approach.

    PubMed

    Amiri, Haleh; Zare, Mohammad; Widory, David

    2015-01-01

    Nitrate ([Formula: see text]) is one of the major threats to the quality of the drinking water taken from the Shiraz aquifer. This aquifer undergoes high anthropogenic pressures from multiple local urban (including uncontrolled sewage systems), agricultural and industrial activities, resulting in [Formula: see text] concentrations as high as 149 mg L(-1), well above the 50 mg L(-1) guideline defined by the World Health Organisation. We coupled here classical chemical and dual isotope (δ(15)N and δ(18)O of [Formula: see text]) approaches trying to characterize sources and potential processes controlling the budget of this pollutant. Chemical data indicate that nitrate in this aquifer is explained by distinct end-members: while mineral fertilizers isotopically show to have no impact, our isotope approach identifies natural soil nitrification and organic [Formula: see text] (manure and/or septic waste) as the two main contributors. Isotope data suggest that natural denitrification may occur within the aquifer, but this conclusion is not supported by the study of other chemical parameters.

  1. Prevalence of incidental pulmonary findings and early follow-up results in patients undergoing dual-source 64-slice computed tomography coronary angiography.

    PubMed

    Yorgun, Hikmet; Kaya, Ergün Barş; Hazirolan, Tuncay; Ateş, Ahmet Hakan; Canpolat, Uğur; Sunman, Hamza; Aytemr, Kudret; Kabakçi, Giray; Tokgözoğlu, Lale; Karçaaltincaba, Muşturay; Akata, Deniz; Oto, Ali

    2010-01-01

    In this study, we aimed to evaluate the incidence of pulmonary abnormalities and document early follow-up results in subjects undergoing multislice computed tomography coronary angiography for the assessment of coronary artery disease. In this retrospective analysis, 1206 patients including 701 men (58.1%) with a mean age of 58.75 (SD, 11.4) years were involved in the study who underwent coronary multislice computed tomography imaging with a 64-slice dual-source scanner. Pulmonary abnormalities were reported as nodules, pulmonary mass, emphysema, bullae, atelectasia, bronchiectasia, pleural effusion, pulmonary fibrosis, and other findings. In total, 186 pulmonary abnormalities were detected in 171 patients (14.1%). Of those, 90 (48.4%) were pulmonary nodules, and 30 (16.1%) were emphysema. Also, we report 3 cases of lung cancer, and 1 case of breast cancer. Early follow-up results revealed stable pulmonary findings. Multislice computed tomography can give important clues including diseases regarding the pulmonary system. It is essential for the reporting practitioner to review the entire scan for pulmonary pathological findings.

  2. Comparison of Image Quality, Diagnostic Accuracy and Radiation Dose Between Flash Model and Retrospective ECG-Triggered Protocols in Dual Source Computed Tomography (DSCT) in Congenital Heart Diseases

    PubMed Central

    Wang, Rong; Xu, Xiang-Jiu; Huang, Gang; Zhou, Xing; Zhang, Wen-Wen; Ma, Ya-Qiong; Zuo, Xiao-na

    2017-01-01

    Summary Background Dual source computed tomography (DSCT) plays an important role in the diagnosis of congenital heart diseases (CHD). However, the issue of radiation-related side effects constitutes a wide public concern. The aim of the study was to explore the differences in diagnostic accuracy, radiation dose and image quality between a prospectively ECG – triggered high – pitch spiral acquisition (flash model) and a retrospective ECG-gated protocol of DSCT used for the detection of CHD. Material/Methods The study included 58 patients with CHD who underwent a DSCT examination, including two groups of 29 patients in each protocol. Then, both subjective and objective image quality, diagnostic accuracy and radiation dose were compared between the two protocols. Results The image quality and the total as well as partial diagnostic accuracy did not differ significantly between the protocols. The radiation dose in the flash model was obviously lower than that in the retrospective model (P<0.05). Conclusions Compared to the retrospective protocol, the flash model can significantly reduce the dose of radiation, while maintaining both diagnostic accuracy and image quality. PMID:28344686

  3. Clinical application of dual-source CT in the evaluation of patients with lung cancer: correlation with perfusion scintigraphy and pulmonary function tests.

    PubMed

    Fraioli, F; Serra, G; Liberali, S; Fiorelli, A; Liparulo, V; Zaccagna, F; Ciccariello, G; Catalano, C; Passariello, R

    2011-09-01

    This study was done to assess the diagnostic potential of dual-source computed tomography (DSCT) in the functional evaluation of lung cancer patients undergoing surgical resection. The CT data were compared with pulmonary perfusion scintigraphy and pulmonary function tests (PFTs). All patients were evaluated with DSCT, scintigraphy and PFTs. The DSCT scan protocol was as follows: two tubes (80 and 140 kV; Care Dose protocol); 70 cc of contrast material (5 cc/s); 5- to 6-s scan time; 0.6 mm collimation. After the automatic calculation of lung perfusion with DSCT and quantification of air volumes and emphysema with dedicated software applications, the perfusional CT studies were compared with scintigraphy using a visual score for perfusion defects; CT air volumes and emphysema were compared with PFTs. The values of accuracy, sensitivity, specificity and positive (PPV) and negative (NPV) predictive values of DSCT compared with perfusion scintigraphy as the reference standard were: 0.88, 0.84, 0.90, 0.93 and 0.88, respectively. The McNemar test did not identify significant differences either between the two imaging techniques (p=0.07) or between CT and PFTs (p=0.09). DSCT is a robust and promising technique that provides important and accurate information on lung function.

  4. 3T MRI and 128-slice dual-source CT cisternography images of the cranial nerves a brief pictorial review for clinicians.

    PubMed

    Roldan-Valadez, Ernesto; Martinez-Anda, Jaime J; Corona-Cedillo, Roberto

    2014-01-01

    There is a broad community of health sciences professionals interested in the anatomy of the cranial nerves (CNs): specialists in neurology, neurosurgery, radiology, otolaryngology, ophthalmology, maxillofacial surgery, radiation oncology, and emergency medicine, as well as other related fields. Advances in neuroimaging using high-resolution images from computed tomography (CT) and magnetic resonance (MR) have made highly-detailed visualization of brain structures possible, allowing normal findings to be routinely assessed and nervous system pathology to be detected. In this article we present an integrated perspective of the normal anatomy of the CNs established by radiologists and neurosurgeons in order to provide a practical imaging review, which combines 128-slice dual-source multiplanar images from CT cisternography and 3T MR curved reconstructed images. The information about the CNs includes their origin, course (with emphasis on the cisternal segments and location of the orifices at the skull base transmitting them), function, and a brief listing of the most common pathologies affecting them. The scope of the article is clinical anatomy; readers will find specialized texts presenting detailed information about particular topics. Our aim in this article is to provide a helpful reference for understanding the complex anatomy of the cranial nerves. Copyright © 2013 Wiley Periodicals, Inc.

  5. Modulations of the plasma uniformity by low frequency sources in a large-area dual frequency inductively coupled plasma based on fluid simulations

    SciTech Connect

    Sun, Xiao-Yan; Zhang, Yu-Ru; Li, Xue-Chun; Wang, You-Nian

    2015-05-15

    As the wafer size increases, dual frequency (DF) inductively coupled plasma (ICP) sources have been proposed as an effective method to achieve large-area uniform plasma processing. A two-dimensional (2D) self-consistent fluid model, combined with an electromagnetic module, has been employed to investigate the influence of the low frequency (LF) source on the plasma radial uniformity in an argon DF discharge. When the DF antenna current is fixed at 10 A, the bulk plasma density decreases significantly with the LF due to the less efficient heating, and the best radial uniformity is obtained at 3.39 MHz. As the LF decreases to 2.26 MHz, the plasma density is characterized by an edge-high profile, and meanwhile the maximum of the electron temperature appears below the outer two-turn coil. Moreover, the axial ion flux at 3.39 MHz is rather uniform in the center region except at the radial edge of the substrate, where a higher ion flux is observed. When the inner five-turn coil frequency is fixed at 2.26 MHz, the plasma density profiles shift from edge-high over uniform to center-high as the LF coil current increases from 6 A to 18 A, and the best plasma uniformity is obtained at 14 A. In addition, the maximum of the electron temperature becomes lower with a second peak appears at the radial position of r = 9 cm at 18 A.

  6. Fiber laser driven dual photonic crystal fiber femtosecond mid-infrared source tunable in the range of 4.2 to 9 μm

    NASA Astrophysics Data System (ADS)

    Yao, Yuhong; Knox, Wayne H.

    2014-02-01

    We report a fiber based approach to broadly tunable femtosecond mid-IR source based on difference frequency mixing of the outputs from dual photonic crystal fibers (PCF) pumped by a femtosecond fiber laser, which is a custom-built Yb-doped fiber chirped pulse amplifier (CPA) delivering 1.35 W, 300 fs, 40 MHz pulses centered at 1035 nm. The CPA output is split into two arms to pump two different types of PCFs for generation of the spectrally separated pulses. The shorter wavelength pulses are generated in one PCF with its single zero dispersion wavelength (ZDW) at 1040 nm. Low normal dispersion around the pumping wavelength enables spectral broadening dominated by self-phase modulation (SPM), which extends from 970 to 1092 nm with up to 340 mW of average power. The longer wavelength pulses are generated in a second PCF which has two closely spaced ZDWs around the laser wavelength. Facilitated by its special dispersion profile, the laser wavelength is converted to the normal dispersion region of the fiber, leading to the generation of the narrow-band intense Stokes pulses with 1 to 1.25 nJ of pulse energy at a conversion efficiency of ~30% from the laser pulses. By difference mixing the outputs from both PCFs in a type-II AgGaS2 crystal, mid-IR pulses tunable from 4.2 to 9 μm are readily generated with its average power ranging from 135 - 640 μW, corresponding to 3 - 16 pJ of pulse energy which is comparable to the reported fiber based mid-IR sources enabled by the solitons self-frequency shift (for example, 3 - 10 μm with 10 pJ of maximum pulse energy in [10]). The reported approach provides a power-scalable route to the generation of broadly tunable femtosecond mid-IR pulses, which we believe to be a promising solution for developing compact, economic and high performance mid-IR sources.

  7. Dual stable isotopic analysis of nitrogen and oxygen to evaluate sources and sinks of atmospheric anthropogenic nitrate in the Colorado Desert

    NASA Astrophysics Data System (ADS)

    Bell, M. D.; Allen, E. B.; Sickman, J. O.

    2010-12-01

    Industrial, automotive, and agricultural emissions release nitrogen into the atmosphere which is subsequently deposited to the surrounding terrestrial ecosystem. The Colorado Desert is impacted by nitrogen deposition from the west due to inputs from the Los Angeles air basin as well as nearby sources from agriculture in the Coachella Valley (CV). Current research within the Colorado Desert has demonstrated that anthropogenic N deposition contributes to the increased biomass of exotic invasive grasses, which compete with native species and can create enough biomass to carry fire in areas of high deposition. To measure the anthropogenic nitrogen within the CV, an array of passive air samplers was erected spanning the valley from west to east. Each sampler contained filters to passively collect both nitric acid and ammonia ions. To evaluate the degree to which the local ecosystem is supplemented by atmospheric N and determine how nitrogen pools are transformed, surface soil and leaf tissue of the dominant shrub, Larrea tridentata, were collected at each site. Only nitrate data from the samplers has currently been analyzed. δ15N, δ17O, and δ18O were obtained from atmospheric and 1M KCl soil extracts using dual isotopic analysis of NO3-. δ15N of vegetation was obtained through combustion of dried leaf tissue. The highest concentrations of atmospheric nitrate are located on the western edge of the desert in the direction toward Los Angeles, and there is also high nitrate near the Salton Sea. The isoscape produced by the isotopic analysis provides a map further describing how NO3- molecules are moving through the desert. This map shows which sources are influencing deposition sinks across the valley. Soil concentrations of nitrogen increase along the same gradient and have an inverse relationship with δ15N. Plant tissue is also less enriched in δ15N at high deposition sites, which correlates with soil values and may be caused by increased fractionation of nitrogen

  8. Closing in on the K edge: coronary CT angiography at 100, 80, and 70 kV-initial comparison of a second- versus a third-generation dual-source CT system.

    PubMed

    Meyer, Mathias; Haubenreisser, Holger; Schoepf, U Joseph; Vliegenthart, Rozemarijn; Leidecker, Christianne; Allmendinger, Thomas; Lehmann, Ralf; Sudarski, Sonja; Borggrefe, Martin; Schoenberg, Stefan O; Henzler, Thomas

    2014-11-01

    To prospectively evaluate radiation and contrast medium requirements for performing high-pitch coronary computed tomographic (CT) angiography at 70 kV using a third-generation dual-source CT system in comparison to a second-generation dual-source CT system. All patients gave informed consent for this institutional review board-approved study. Forty-five patients (median age, 52 years; 27 men) were imaged in high-pitch mode with a third-generation dual-source CT system at 70 kV (n = 15) or with a second-generation dual-source CT system at 80 or 100 kV (n = 15 for each). Tube voltage was based on body mass index: 80 or 70 kV for less than 26 kg/m(2) versus 100 kV for 26-30 kg/m(2). For the 80- and 100-kV protocols, 80 mL of contrast material was injected, versus 45 mL for the 70-kV protocol. Data were reconstructed by using a second-generation iterative reconstruction algorithm for second-generation dual-source CT and a recently introduced third-generation iterative reconstruction algorithm for third-generation dual-source CT. Objective image quality was measured for various regions of interest, and subjective image quality was evaluated with a five-point Likert scale. The signal-to-noise ratio of the coronary CT angiography studies acquired with 70 kV was significantly higher (70 kV: 14.3-17.6 vs 80 kV: 7.1-12.9 vs 100 kV: 9.8-12.9; P < .0497) than those acquired with the other two protocols for all coronary arteries. Qualitative image quality analyses revealed no significant differences between the three CT angiography protocols (median score, 5; P > .05). The mean effective dose was 75% and 108% higher (0.92 mSv ± 0.3 [standard deviation] and 0.78 mSv ± 0.2 vs 0.44 mSv ± 0.1; P < .0001), respectively, for the 80- and 100-kV CT angiography protocols than for the 70-kV CT angiography protocol. In nonobese patients, third-generation high-pitch coronary dual-source CT angiography at 70 kV results in robust image quality for studying the coronary arteries, at

  9. [Application of single-source dual-energy spectral CT in differentiating lymphoma and metastatic lymph nodes in the head and neck].

    PubMed

    Wang, Xiaoyi; Zhao, Yanfeng; Wu, Ning; Yang, Liang; Li, Lin; Zhu, Zheng; Luo, Dehong

    2015-05-01

    To investigate the feasibility of differentiation of lymphoma, metastatic lymph nodes of squamous cell carcinoma (SCC) and papillary thyroid carcinoma (PTC) in the head and neck by single-source dual-energy spectral CT. 25 cases of non-Hodgkin lymphoma (NHL) with 236 lymph nodes, 3 cases of Hodgkin's lymphoma (HL) with 32 lymph nodes, 21 cases of SCC with 86 lymph nodes and 19 cases of PTC with 92 lymph nodes were evaluated by enhanced GSI. CT attenuation of lymph nodes in the monochromatic images at different keV levels and the iodine and water contents of these lymph nodes were measured. The slope of spectral curve was calculated using CT value at 40 keVand 90 keV. All results were analyzed with ANOVA and t test. 70 keV had the best single energy images. Normalized Hounsfield unit (NHU) of diffuse large B-cell lymphoma (DLBCL), follicular lymphoma (FL), T lymphoblastic lymphoma (T-LBL), HL, PTC and SCC was 0.32 ± 0.10, 0.46 ± 0.08, 0.41 ± 0.11, 0.41 ± 0.11, 0.56 ± 0.15 and 0.34 ± 0.16, respectively. Normalized iodine concentration (NIC) of them was 0.20 ± 0.08, 0.32 ± 0.08, 0.25 ± 0.09, 0.30 ± 0.12, 0.49 ± 0.18 and 0.23 ± 0.18, respectively. The slope of spectral curve (k) of them was -1.92 ± 0.55, -2.45 ± 0.60, -1.82 ± 0.57, -2.57 ± 0.54, -5.44 ± 2.41 and -1.97 ± 0.81, respectively. Compared with the NHU, there was a statistically significant difference in each pair except DLBCL and SCC, and T-LBL and HL. Compared with the NIC, there was a statistically significant difference in each pair except DLBCL and SCC, FL and HL, T-LBL and SCC, and T-LBL and HL. Compared with the slope of spectral curve, there was statistically significant difference in each pair except DLBCL and T-LBL, DLBCL and SCC, FL and HL, and T-LBL and SCC. Malignant lymph nodes of different types of diseases have certain different values of quantitative parameters in spectral CT imaging. By using CT attenuation, the shape and slope of spectral curve and the iodine content

  10. Radiation dose and diagnostic accuracy of high-pitch dual-source coronary angiography in the evaluation of coronary artery stenoses.

    PubMed

    Koplay, M; Erdogan, H; Avci, A; Sivri, M; Demir, K; Guler, I; Demir, L S; Paksoy, Y

    2016-04-01

    "Flash Spiral" imaging is a new prospective ECG-triggered spiral scan mode that uses a very high-pitch for coronary computed tomography angiography (CTA). This enables complete image acquisition within one cardiac cycle with a very low radiation exposure. The aim of this study was to investigate the diagnostic accuracy, image quality, and effective radiation dose of prospectively ECG-triggered high-pitch spiral method (Flash spiral mode) of coronary CTA using dual-source technology for the evaluation of coronary artery stenoses. The study included 186 consecutive patients (115men, 71women; mean age: 53.37 years) who underwent coronary CTA. Coronary CTA was performed with a 128×2-slice dual-source CT (Somatom Definition Flash, Siemens, Germany) using a prospectively ECG-triggered high-pitch spiral mode. Patients were divided into three groups according to heart rate (≤65bpm, 66-75bpm, ≥76bpm) and body mass index (BMI) (20-24kg/m(2), 25-29kg/m(2), 30-34kg/m(2)) values. The correlation between heart rates, image quality and BMI values are investigated. A four-point scale (1=excellent, 4=poor/non-diagnostic) was used to rank the comparative image quality. Effective radiation doses were calculated. Also the correlation between radiation dose, sex and BMI values were investigated. In addition, diagnostic accuracy of CTA for detection of significant (≥50%) coronary artery stenoses was compared with invasive coronary angiography findings of 612vessel segments in 38patients. The sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy rate were calculated. A total of 2976coronary artery segments were present. Of all coronary artery segments, 2381 (80%) had an image quality score of 1, and 1.5% segments were rated as "poor/non-diagnostic". When the correlation between heart rate and image quality is investigated, there was a significant difference between ≤65bpm and ≥76bpm groups. However, there was no significant

  11. Serial changes in anatomy and ventricular function on dual-source cardiac computed tomography after the Norwood procedure for hypoplastic left heart syndrome.

    PubMed

    Goo, Hyun Woo

    2017-09-06

    Accurate evaluation of anatomy and ventricular function after the Norwood procedure in hypoplastic left heart syndrome is important for treatment planning and prognostication, but echocardiography and cardiac MRI have limitations. To assess serial changes in anatomy and ventricular function on dual-source cardiac CT after the Norwood procedure for hypoplastic left heart syndrome. In 14 consecutive patients with hypoplastic left heart syndrome, end-systolic and end-diastolic phase cardiac dual-source CT was performed before and early (average: 1 month) after the Norwood procedure, and repeated late (median: 4.5 months) after the Norwood procedure in six patients. Ventricular functional parameters and indexed morphological measurements including pulmonary artery size, right ventricular free wall thickness, and ascending aorta size on cardiac CT were compared between different time points. Moreover, morphological features including ventricular septal defect, endocardial fibroelastosis and coronary ventricular communication were evaluated on cardiac CT. Right ventricular function and volumes remained unchanged (indexed end-systolic and end-diastolic volumes: 38.9±14.0 vs. 41.1±21.5 ml/m(2), P=0.7 and 99.5±30.5 vs. 105.1±33.0 ml/m(2), P=0.6; ejection fraction: 60.1±7.3 vs. 63.8±7.0%, P=0.1, and indexed stroke volume: 60.7±18.0 vs. 64.0±15.6 ml/m(2), P=0.5) early after the Norwood procedure, but function was decreased (ejection fraction: 64.2±2.6 vs. 58.1±7.1%, P=0.01) and volume was increased (indexed end-systolic and end-diastolic volumes: 39.2±14.9 vs. 68.9±20.6 ml/m(2), P<0.003 and 107.8±36.5 vs. 162.9±36.2 ml/m(2), P<0.006, and indexed stroke volume: 68.6±21.7 vs. 94.0±21.3 ml/m(2), P=0.02) later. Branch pulmonary artery size showed a gradual decrease without asymmetry after the Norwood procedure. Right and left pulmonary artery stenoses were identified in 21.4% (3/14) of the patients. Indexed right ventricular free wall thickness showed a

  12. Application of prospective ECG-gated high-pitch 128-slice dual-source CT angiography in the diagnosis of congenital extracardiac vascular anomalies in infants and children.

    PubMed

    Nie, Pei; Yang, Guangjie; Wang, Ximing; Duan, Yanhua; Xu, Wenjian; Li, Haiou; Cao, Ting; Liu, Xuejun; Ji, Xiaopeng; Cheng, Zhaoping; Wang, Anbiao

    2014-01-01

    To investigate the value of prospective ECG-gated high-pitch 128-slice dual-source CT (DSCT) angiography in the diagnosis of congenital extracardiac vascular anomalies in infants and children in comparison with transthoracic echocardiography (TTE). Eighty consecutive infants or children clinically diagnosed of congenital heart disease and suspected with extracardiac vascular anomaly were enrolled, and 75 patients were finally included in this prospective study. All patients underwent prospective ECG-gated high-pitch DSCT angiography after TTE with an interval of 1-7 days. The diagnostic accuracy and sensitivity of high-pitch DSCT angiography and TTE were compared according to the surgical/CCA findings. The image quality of DSCT was assessed using a five-point scale. The effective radiation dose (ED) was calculated. A total of 17 congenital heart diseases and 162 separate extracardiac vascular anomalies were confirmed by surgical/CCA findings in 75 patients. The diagnostic accuracy of high-pitch DSCT angiography and TTE was 99.67% and 97.89%, respectively. The sensitivity of high-pitch DSCT angiography and TTE was 97.53% and 79.62%, respectively. There was significant difference regarding to the diagnostic accuracy and the sensitivity between high-pitch DSCT angiography and TTE (χ2 = 23.561 and 28.013, P<0.05). The agreement on the image quality scoring of DSCT between the two observers was excellent (κ = 0.81), and the mean score of image quality was 4.1±0.7. The mean ED of DSCT was 0.29±0.08 mSv. Prospective ECG-gated high-pitch 128-slice DSCT angiography with low radiation dose and high diagnostic accuracy has higher sensitivity compared to TTE in the detection of congenital extracardiac vascular anomalies in infants and children.

  13. Initial results of a new generation dual source CT system using only an in-plane comb filter for ultra-high resolution temporal bone imaging.

    PubMed

    Meyer, Mathias; Haubenreisser, Holger; Raupach, Rainer; Schmidt, Bernhard; Lietzmann, Florian; Leidecker, Christianne; Allmendinger, Thomas; Flohr, Thomas; Schad, Lothar R; Schoenberg, Stefan O; Henzler, Thomas

    2015-01-01

    To prospectively evaluate radiation dose and image quality of a third generation dual-source CT (DSCT) without z-axis filter behind the patient for temporal bone CT. Forty-five patients were either examined on a first, second, or third generation DSCT in an ultra-high-resolution (UHR) temporal bone-imaging mode. On the third generation DSCT system, the tighter focal spot of 0.2 mm(2) removes the necessity for an additional z-axis-filter, leading to an improved z-axis radiation dose efficiency. Images of 0.4 mm were reconstructed using standard filtered-back-projection or iterative reconstruction (IR) technique for previous generations of DSCT and a novel IR algorithm for the third generation DSCT. Radiation dose and image quality were compared between the three DSCT systems. The statistically significantly highest subjective and objective image quality was evaluated for the third generation DSCT when compared to the first or second generation DSCT systems (all p < 0.05). Total effective dose was 63%/39% lower for the third generation examination as compared to the first and second generation DSCT. Temporal bone imaging without z-axis-UHR-filter and a novel third generation IR algorithm allows for significantly higher image quality while lowering effective dose when compared to the first two generations of DSCTs. • Omitting the z-axis-filter allows a reduction in radiation dose of 50% • A smaller focal spot of 0.2 mm (2) significantly improves spatial resolution • Ultra-high-resolution temporal-bone-CT helps to gain diagnostic information of the middle/inner ear.

  14. Diagnostic Accuracy of Endocardial-to-Epicardial Myocardial Blood Flow Ratio for the Detection of Significant Coronary Artery Disease With Dynamic Myocardial Perfusion Dual-Source Computed Tomography.

    PubMed

    Goto, Yoshitaka; Kitagawa, Kakuya; Uno, Mio; Nakamori, Shiro; Ito, Tatsuro; Nagasawa, Naoki; Dohi, Kaoru; Sakuma, Hajime

    2017-04-25

    Previous dynamic stress computed tomography perfusion (CTP) studies used absolute myocardial blood flow (MBF in mL/100 g/min) as a threshold to discriminate flow-limiting coronary artery disease (CAD), but absolute MBF can be vary because of multiple factors. The aim of this study was to compare the diagnostic performance of absolute MBF and the transmural perfusion ratio (TPR) for the detection of flow-limiting CAD, and to clarify the influence of CT delayed enhancement (CTDE) on the diagnostic performance of CTP.Methods and Results:We retrospectively enrolled 51 patients who underwent dual-source CTP and invasive coronary angiography (ICA). TPR was defined as the endocardial MBF of a specific segment divided by the mean of the epicardial MBF of all segments. Flow-limiting CAD was defined as luminal diameter stenosis >90% on ICA or a lesion with fractional flow reserve ≤0.8. Segmental presence and absence of myocardial scar was determined by CTDE. The area under the receiver-operating characteristics curve (AUC) of TPR was significantly greater than that of MBF for the detection of flow-limiting CAD (0.833 vs. 0.711, P=0.0273). Myocardial DE was present in 27 of the 51 patients and in 34 of 143 territories. When only territories containing DE were considered, the AUC of TPR decreased to 0.733. TPR calculated from absolute MBF demonstrated higher diagnostic performance for the discrimination of flow-limiting CAD when compared with absolute MBF itself.

  15. Measurement of the ascending aorta diameter in patients with severe bicuspid and tricuspid aortic valve stenosis using dual-source computed tomography coronary angiography.

    PubMed

    Son, Jee Young; Ko, Sung Min; Choi, Jin Woo; Song, Meong Gun; Hwang, Hweung Kon; Lee, Sook Jin; Kang, Joon-Won

    2011-12-01

    We aimed to evaluate the diagnostic performance of dual-source computed tomography coronary angiography (DSCT-CA) in the measurement of the ascending aorta (AA) diameter and compare the AA diameter in patients with severe bicuspid aortic valve (BAV) and tricuspid aortic valve (TAV) stenosis. Eighty-eight consecutive patients (50 men, mean age 60.3 ± 13 year) with severe aortic stenosis (AS) underwent DSCT-CA before aortic valve surgery. Seventy-four of the 88 patients underwent cardiovascular magnetic resonance (CMR). The internal diameter of AA was measured from early-systole with DSCT-CA and CMR by 2 radiologists independently at 4 levels (aortic annulus, sinuses of Valsalva, sinotubular junction, and tubular portion at the right pulmonary artery). The patients were divided in to 2 groups (BAV [n = 53]; TAV [n = 35]) according to operative findings. Patients with BAV were significantly younger than those with TAV (P = 0.0035). Inter-observer agreement of AA diameters at 4 levels with DSCT-CA and CMR was excellent (intraclass correlation coefficient = 0.89-0.97). Also, the DSCT-CA and CMR measurements of the AA diameter strongly correlated (r = 0.871-0.976). Mean diameter of the AA by DSCT-CA was significantly larger in patients with BAV (34.4 ± 8.2 mm) as compared to those with TAV (30.6 ± 5.5 mm). The diameters at the sinuses of Valsalva, sinotubular junction, and tubular portion were significantly larger in BAV than in TAV. Twenty-two of 53 (41.5%) patients with BAV and 2 of 35 (5.7%) patients with TAV had AA dilatation > 45 mm. DSCT-CA allows accurate assessment of the AA diameters in patients with severe AS. Patients with severe BAV stenosis had larger AA diameters and higher prevalence of AA dilatation > 45 mm as compared to those with severe TAV stenosis.

  16. Quantification of left coronary bifurcation angles and plaques by coronary computed tomography angiography for prediction of significant coronary stenosis: A preliminary study with dual-source CT

    PubMed Central

    Cui, Yue; Zeng, Wenjuan; Yu, Jie; Lu, Jing; Hu, Yuannan; Diao, Nan; Liang, Bo; Han, Ping; Shi, Heshui

    2017-01-01

    Purpose To evaluate the diagnostic performance of left coronary bifurcation angles and plaque characteristics for prediction of coronary stenosis by dual-source CT. Methods 106 patients suspected of coronary artery disease undergoing both coronary computed tomography angiography (CCTA) and invasive coronary angiography (CAG) within three months were included. Left coronary bifurcation angles including the angles between the left anterior descending artery and left circumflex artery (LAD-LCx), left main coronary artery and left anterior descending artery (LM-LAD), left main coronary artery and left circumflex artery (LM-LCx) were measured on CT images. CCTA plaque parameters were calculated by plaque analysis software. Coronary stenosis ≥ 50% by CAG was defined as significant. Results 106 patients with 318 left coronary bifurcation angles and 126 vessels were analyzed. The bifurcation angle of LAD-LCx was significantly larger in left coronary stenosis ≥ 50% than stenosis < 50%, and significantly wider in the non-calcified plaque group than calcified. Multivariable analyses showed the bifurcation angle of LAD-LCx was an independent predictor for significant left coronary stenosis (OR = 1.423, P = 0.002). In ROC curve analysis, LAD-LCx predicted significant left coronary stenosis with a sensitivity of 66.7%, specificity of 78.4%, positive predictive value of 85.2% and negative predictive value of 55.8%. The lipid plaque volume improved the diagnostic performance of CCTA diameter stenosis (AUC: 0.854 vs. 0.900, P = 0.045) in significant coronary stenosis. Conclusions The bifurcation angle of LAD-LCx could predict significant left coronary stenosis. Wider LAD-LCx is related to non-calcified lesions. Lipid plaque volume could improve the diagnostic performance of CCTA for coronary stenosis prediction. PMID:28346530

  17. Update on multidetector coronary CT angiography of coronary stents: in vitro evaluation of 29 different stent types with dual-source CT.

    PubMed

    Maintz, David; Burg, Matthias C; Seifarth, Harald; Bunck, Alexander C; Ozgün, Murat; Fischbach, Roman; Jürgens, Kai Uwe; Heindel, Walter

    2009-01-01

    The aim of this study was to test a large sample of the latest coronary artery stents using four image reconstruction approaches with respect to lumen visualization, lumen attenuation, and image noise in dual-source multidetector row CT (DSCT) in vitro and to provide a CT catalogue of currently used coronary artery stents. Twenty-nine different coronary artery stents (19 steel, 6 cobalt-chromium, 2 tantalum, 1 iron, 1 magnesium) were examined in a coronary artery phantom (vessel diameter 3 mm, intravascular attenuation 250 HU, extravascular density -70 HU). Stents were imaged in axial orientation with standard parameters: 32 x 0.6 collimation, pitch 0.24, 400 mAs, 120 kV, rotation time 0.33 s. Image reconstructions were obtained with four different convolution kernels (soft, medium-soft, standard high-resolution, stent-dedicated). To evaluate visualization characteristics of the stent, the lumen diameter, intraluminal density, and noise were measured. The stent-dedicated kernel offered best average lumen visualization (54 +/- 8.3%) and most realistic lumen attenuation (222 +/- 44 HU) at the expense of increased noise (23.9 +/- 1.9 HU) compared with standard CTA protocols (p < 0.001 for all). The magnesium stent showed the least artifacts with a lumen visibility of 90%. The majority of stents (79%) exhibited a lumen visibility of 50-59%. Less than half of the stent lumen was visible in only six stents. Stent lumen visibility largely varies depending on the stent type. Magnesium is by far more favorable a stent material with regard to CT imaging when compared with the more common materials steel, cobalt-chromium, or tantalum. The magnesium stent exhibits a lumen visibility of 90%, whereas the majority of the other stents exhibit a lumen visibility of 50-59%.

  18. Myocardial delayed enhancement with dual-source CT: advantages of targeted spatial frequency filtration and image averaging over half-scan reconstruction.

    PubMed

    Kurobe, Yusuke; Kitagawa, Kakuya; Ito, Tatsuro; Kurita, Yoshie; Shiraishi, Yasuyuki; Nakamori, Shiro; Nakajima, Hiroshi; Nagata, Motonori; Ishida, Masaki; Dohi, Kaoru; Ito, Masaaki; Sakuma, Hajime

    2014-01-01

    Clinical utility of myocardial delayed-enhancement CT is currently limited because of relatively poor contrast-to-noise ratio (CNR) and artifacts. Targeted spatial-frequency filtration (TSFF) is a hybrid algorithm of half- and full-scan reconstruction that can achieve both high temporal resolution and improved stability of myocardial signal. The purpose of this study was to evaluate image quality of delayed-enhancement CT using TSFF with image averaging and its reproducibility in infarct assessment in comparison with conventional half-scan reconstruction (HALF). Forty patients with suspected coronary artery disease underwent delayed-enhancement CT with HALF and TSFF using dual-source CT. Two blinded readers independently determined the presence and size of delayed enhancement. Image quality, signal-to-noise ratio and CNR were assessed. The presence of delayed enhancement on CT was compared with magnetic resonance imaging in 12 patients. TSFF with averaging of 4 image stacks acquired during 1 breathhold demonstrated significantly better image quality compared with HALF. Good left ventricular lumen-myocardium contrast was consistently achieved with TSFF in patients who received iodine dose of >600 mg I/kg. The signal-to-noise ratio and CNR were 11.3 ± 4.2 and 4.5 ± 1.6 by TSFF, being significantly higher than those by HALF (7.9 ± 2.9 and 3.3 ± 1.8; P < .01 for both). Interobserver reproducibility of infarct sizing was markedly improved by using TSFF instead of HALF (intraclass correlation coefficient: 0.86 vs 0.50). Agreement with magnetic resonance imaging by kappa statistics was 0.85 with TSFF and 0.74 with HALF. TSFF with image averaging can significantly improve image quality of delayed-enhancement CT and considerably enhances interobserver reproducibility of infarct sizing. Copyright © 2014 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  19. Semi-automatic measurement of left ventricular function on dual source computed tomography using five different software tools in comparison with magnetic resonance imaging.

    PubMed

    de Jonge, G J; van der Vleuten, P A; Overbosch, J; Lubbers, D D; Jansen-van der Weide, M C; Zijlstra, F; van Ooijen, P M A; Oudkerk, M

    2011-12-01

    To compare left ventricular (LV) function assessment using five different software tools on the same dual source computed tomography (DSCT) datasets with the results of MRI. Twenty-six patients, undergoing cardiac contrast-enhanced DSCT were included (20 men, mean age 59±12 years). Reconstructions were made at every 10% of the RR-interval. Function analysis was performed with five different, commercially available workstations. In all software tools, semi-automatic LV function measurements were performed, with manual corrections if necessary. Within 0-22 days, all 26 patients were scanned on a 1.5 T MRI-system. Bland-Altman analysis was performed to calculate limits of agreement between DSCT and MRI. Pearson's correlation coefficient was calculated to assess the correlation between the different DSCT software tools and MRI. Repeated measurements were performed to determine intraobserver and interobserver variability. For all five DSCT workstations, mean LV functional parameters correlated well with measurements on MRI. Bland-Altman analysis of the comparison of DSCT and MRI showed acceptable limits of agreement. Best correlation and limits of agreement were obtained by DSCT software tools with software algorithms comparable to MRI software. The five different DSCT software tools we examined have interchangeable results of LV functional parameters compared to regularly analysed results by MRI. The best correlation and the narrowest limits of agreement were found when the same software algorithm was used for both DSCT and MRI examinations, therefore our advice for clinical practice is to always evaluate images with the same type of post-processing tools in follow-up. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  20. Adaptive prospective ECG-triggered sequence coronary angiography in dual-source CT without heart rate control: Image quality and diagnostic performance.

    PubMed

    Pan, Chang-Jie; Qian, Nong; Wang, Tao; Tang, Xiao-Qiang; Xue, Yue-Jun

    2013-02-01

    The aim of this study was to evaluate the accuracy of using second generation dual-source CT (DSCT) to obtain high quality images and diagnostic performance and to reduce the radiation dose in adaptive prospective electrocardiography (ECG)-triggered sequence (CorAdSeq) CT coronary angiography (CTCA) without heart rate control. No prescan β-blockers were administered. Un-enhanced CT and CTCA with adaptive prospective CorAdSeq scanning without heart rate control were performed in 683 consecutive patients divided into two body mass index (BMI) groups: BMI <25 kg/m(2) (group A, n=412) and BMI ≥25 kg/m(2) (group B, n=271). The image quality and quantitative stenosis of all coronary segments with a diameter ≥1 mm were assessed. The mean heart rate (MHR), heart rate variability (HRV) and radiation dose values were recorded. In 426 cases, the diagnostic performance was evaluated using quantitative conventional coronary angiography as the reference standard. Diagnostic image quality was obtained in 98.5% of segments in group A and in 98.8% of segments in group B, with no significant differences between the groups. No correlations were observed between the image quality score and MHR or HRV (P=0.492, P=0.564, respectively). The effective radiation doses in groups A and B were 2.57±1.01 mSv and 6.36±1.88 mSv, respectively. The sensitivities and specificities of diagnosing coronary heart disease per patient were 99.6% and 97.8% in group A and 99.5% and 97.5% in group B, respectively (P>0.05). Adaptive prospective CorAdSeq scanning, without heart rate control, by second generation DSCT had a high image quality and diagnostic performance for coronary artery stenosis with lower radiation doses.

  1. A multireader diagnostic performance study of low-contrast detectability on a third-generation dual-source CT scanner: filtered back projection versus advanced modeled iterative reconstruction

    NASA Astrophysics Data System (ADS)

    Solomon, Justin; Mileto, Achille; Ramirez-Giraldo, Juan Carlos; Samei, Ehsan

    2015-03-01

    The purpose of this work was to compare CT low-contrast detectability between two reconstruction algorithms, filtered back-projection (FBP) and advanced modeled iterative reconstruction (ADMIRE). A phantom was designed with a range of low-contrast circular inserts representing 5 contrast levels and 3 sizes. The phantom was imaged on a third-generation dual-source CT scanner (SOMATOM Definition Force, Siemens Healthcare) under various dose levels (0.74 - 5.8 mGy CTDIVol). Images were reconstructed using different settings of slice thickness (0.6 - 5 mm) and reconstruction algorithms (FBP and ADMIRE with strength of 3-5) and were assessed by eleven blinded and independent readers using a two alternative forced choice (2AFC) detection experiment. A second observer experiment was further performed in which observers scored the images based on the total number of visible object groups. Detection performance increased with increasing contrast, size, dose, with accuracy ranging from 50% (i.e., guessing) to 87% with an average inter-observer variability of ±7%. The use of ADMIRE-3 increased performance by 5.2% resulting in an estimated dose reduction potential of 56-60%. The results from the second experiment also showed increased number of visible object groups for increasing dose, slice thickness, and ADMIRE strength. The score difference between FBP and ADMIRE was 0.9, 1.3, and 2.1 for ADMIRE strengths of 3, 4, and 5, respectively, resulting in estimated dose reduction potentials between 4-80%. Overall, the data indicated potential to image at reduced doses while maintaining comparable image quality when using ADMIRE compared to FBP.

  2. Single source dual-energy computed tomography in the diagnosis of gout: Diagnostic reliability in comparison to digital radiography and conventional computed tomography of the feet.

    PubMed

    Kiefer, Tobias; Diekhoff, Torsten; Hermann, Sandra; Stroux, Andrea; Mews, Jürgen; Blobel, Jörg; Hamm, Bernd; Hermann, Kay-Geert A

    2016-10-01

    To investigate the diagnostic value of single-source dual-energy computed tomography (SDECT) in gouty arthritis and to compare its capability to detect urate depositions with digital radiography (DR) and conventional computed tomography (CT). Forty-four patients who underwent SDECT volume scans of the feet for suspected gouty arthritis were retrospectively analyzed. SDECT, CT (both n=44) and DR (n=36) were scored by three blinded readers for presence of osteoarthritis, erosions, and tophi. A diagnosis was made for each imaging modality. Results were compared to the clinical diagnosis using the American College of Rheumatology (ACR) classification criteria. The patient population was divided into a gout (n=21) and control (n=23) group based on final clinical diagnosis. Osteoarthritis was evident in 15 joints using CT and 30 joints using DR (p=0.165). There were 134 erosions detected by CT compared to 38 erosions detected by DR (p<0.001). In total 119 tophi were detected by SDECT, compared to 85 tophi by CT (p=0.182) and 25 tophi by DR (p<0.001). SDECT had best diagnostic value for diagnosis of gout compared to DR and conventional CT (sensitivity and specificity for SDECT: 71.4% and 95.7%, CT: 71.4% and 91.3% and DR: 44.4% and 83.3%, respectively). For all three readers, Cohen's kappa for DR and conventional CT were substantial for all scoring items and ranged from 0.75 to 0.77 and 0.72-0.76, respectively. For SDECT Cohen's kappa was good to almost perfect with 0.77-0.84. SDECT is capable to detect uric acid depositions with good sensitivity and high specificity in feet, therefore diagnostic confidence is improved. Using SDECT, inter-reader variance can be markedly reduced for the detection of gouty tophi. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  3. An evaluation of dual source computed tomography used with the de Weert classification to detect vulnerable plaque, using IVUS virtual histology as a standard of reference.

    PubMed

    Dołęga-Kozierowski, Bartosz; Klimeczek, Piotr; Lis, Michał; Krycińska, Róża; Chrapusta, Anna; Zaleska-Dorobisz, Urszula; Garcarek, Jerzy; Witkiewicz, Wojciech

    2017-01-01

    One of the main risk factors for cerebral ischemic events is atherosclerotic disease of the internal carotid artery (ICA). Nowadays, increasing attention is being paid to the relationship between the morphological features of atherosclerotic plaque and the occurrence of stroke. Several studies have demonstrated that the presence of specific vulnerable plaque types, with a large lipid core and thin fibrous cap, can be used as an independent risk predictor of cerebral ischemic events. The present study is an attempt to develop the method of plaque surface morphology assessment presented by de Weert et al. by correlating the results of Dual Source Computed Tomography (DSCT) with those from intravascular ultrasound virtual histology (IVUS-VH). A group of 30 symptomatic patients (13 men and 17 women; 72 ± 9 years) with ICA stenosis suspected on the basis of ultrasound imaging (US) and confirmed to be above 70% in DSCT underwent intravascular ultrasound (IVUS) imaging. The results of DSCT were categorized according to the de Weert classification. There were 13 cases (43%) with smooth wall surfaces, 10 cases (33%) with discreet wall irregularities, and seven cases (23%) with incursions of contrast, indicating the presence of ulceration. In the IVUS-VH examinations, 4 out of 30 cases (13%) were identified as having adaptive intimal thickening (AIT), 4 (13%) as showing pathological intimal thickening (PIT), 6 (20%) with fibroatheromas (FA), six (20%) with fibrocalcific plaque (FCa), and 10 (33%) as having thin-cap fibroatheroma (TCFA), which is high-risk plaque. Comparing the above results showed that all the patients with confirmed wall ulceration in DSCT were characterized as having high-risk plaque in IVUS-VH. Using DSCT with the de Weert classification of plaque surface morphology makes reliable detection of ulcerations possible; therefore, this could become a significant new technique to improve current imaging protocols for patients with a high risk of ischemic

  4. Dose reduction in abdominal computed tomography: intraindividual comparison of image quality of full-dose standard and half-dose iterative reconstructions with dual-source computed tomography.

    PubMed

    May, Matthias S; Wüst, Wolfgang; Brand, Michael; Stahl, Christian; Allmendinger, Thomas; Schmidt, Bernhard; Uder, Michael; Lell, Michael M

    2011-07-01

    We sought to evaluate the image quality of iterative reconstruction in image space (IRIS) in half-dose (HD) datasets compared with full-dose (FD) and HD filtered back projection (FBP) reconstruction in abdominal computed tomography (CT). To acquire data with FD and HD simultaneously, contrast-enhanced abdominal CT was performed with a dual-source CT system, both tubes operating at 120 kV, 100 ref.mAs, and pitch 0.8. Three different image datasets were reconstructed from the raw data: Standard FD images applying FBP which served as reference, HD images applying FBP and HD images applying IRIS. For the HD data sets, only data from 1 tube detector-system was used. Quantitative image quality analysis was performed by measuring image noise in tissue and air. Qualitative image quality was evaluated according to the European Guidelines on Quality criteria for CT. Additional assessment of artifacts, lesion conspicuity, and edge sharpness was performed. : Image noise in soft tissue was substantially decreased in HD-IRIS (-3.4 HU, -22%) and increased in HD-FBP (+6.2 HU, +39%) images when compared with the reference (mean noise, 15.9 HU). No significant differences between the FD-FBP and HD-IRIS images were found for the visually sharp anatomic reproduction, overall diagnostic acceptability (P = 0.923), lesion conspicuity (P = 0.592), and edge sharpness (P = 0.589), while HD-FBP was rated inferior. Streak artifacts and beam hardening was significantly more prominent in HD-FBP while HD-IRIS images exhibited a slightly different noise pattern. Direct intrapatient comparison of standard FD body protocols and HD-IRIS reconstruction suggest that the latest iterative reconstruction algorithms allow for approximately 50% dose reduction without deterioration of the high image quality necessary for confident diagnosis.

  5. Imaging the Parasinus Region with a Third-Generation Dual-Source CT and the Effect of Tin Filtration on Image Quality and Radiation Dose.

    PubMed

    Lell, M M; May, M S; Brand, M; Eller, A; Buder, T; Hofmann, E; Uder, M; Wuest, W

    2015-07-01

    CT is the imaging technique of choice in the evaluation of midface trauma or inflammatory disease. We performed a systematic evaluation of scan protocols to optimize image quality and radiation exposure on third-generation dual-source CT. CT protocols with different tube voltage (70-150 kV), current (25-300 reference mAs), prefiltration, pitch value, and rotation time were systematically evaluated. All images were reconstructed with iterative reconstruction (Advanced Modeled Iterative Reconstruction, level 2). To individually compare results with otherwise identical factors, we obtained all scans on a frozen human head. Conebeam CT was performed for image quality and dose comparison with multidetector row CT. Delineation of important anatomic structures and incidental pathologic conditions in the cadaver head was evaluated. One hundred kilovolts with tin prefiltration demonstrated the best compromise between dose and image quality. The most dose-effective combination for trauma imaging was Sn100 kV/250 mAs (volume CT dose index, 2.02 mGy), and for preoperative sinus surgery planning, Sn100 kV/150 mAs (volume CT dose index, 1.22 mGy). "Sn" indicates an additional prefiltration of the x-ray beam with a tin filter to constrict the energy spectrum. Exclusion of sinonasal disease was possible with even a lower dose by using Sn100 kV/25 mAs (volume CT dose index, 0.2 mGy). High image quality at very low dose levels can be achieved by using a Sn100-kV protocol with iterative reconstruction. The effective dose is comparable with that of conventional radiography, and the high image quality at even lower radiation exposure favors multidetector row CT over conebeam CT. © 2015 by American Journal of Neuroradiology.

  6. Image quality and radiation dose of 128-slice dual-source CT venography using low kilovoltage combined with high-pitch scanning and automatic tube current modulation.

    PubMed

    Park, Chan Kue; Choo, Ki Seok; Jeon, Ung Bae; Baik, Seung Kug; Kim, Yong Woo; Kim, Tae Un; Kim, Chang Won; Jeong, Yeon Ju; Jeong, Dong Wook; Lim, Soo Jin

    2013-06-01

    To compare vascular enhancement, image quality, and radiation dose of 128-slice dual-source CT venography (CTV) between an imaging setting of 120 kVp with low pitch, and a setting of 100 kVp combined with high pitch and automatic tube current modulation. A total of 100 patients with suspected deep vein thrombosis and varicose veins were divided into two groups: Group 1 [50 patients, 120 kVp, low pitch (0.6), and fixed 120 mA) and Group 2 (50 patients, 100 kVp, high pitch (3.0), and automatic tube current modulation]. Two radiologists, who were blinded to the image protocol, assessed vascular enhancement and image noise in the inferior vena cava (IVC), femoral vein, and popliteal vein. They also assigned an image quality score independently using a 5-point visual scale. Effective dose was estimated using the dose-length product (DLP). Group demographics, radiation dose, vascular enhancement, image noise, and image quality in the two groups were analyzed. Mean vascular enhancement of the IVC, femoral vein, and popliteal vein was significantly higher in group 2 than in group 1, and images in group 2 had significantly higher image noise. However, there were no significant differences in subjective image quality score of the IVC, femoral vein, and popliteal vein. The mean DLP in group 2 (402.10 ± 94.29 mGy cm) was significantly lower than that in group 1 (973.36 ± 63.20 mGy cm) (P < 0.001). Lower extremity CTV using 100 kVp, high pitch (3.0), and automatic tube current modulation improved vascular enhancement with acceptable image quality and low radiation dose.

  7. High-pitch dual-source CT coronary angiography: analysis of the impact on image quality of altered electrocardiography waves during data acquisition.

    PubMed

    Wang, Xiaoling; Fang, Jiliang; Tong, Haibin; Zhao, Qing; Song, Qingqiao; Luo, Ping; Xue, Chao; Zhang, Min; Yang, Shuhua; Wang, Qun; Wang, Ping; Shi, Fengxiang; Xu, Lei; Rong, Peijing

    2012-06-01

    Electrocardiography (ECG) "altered waves" sometimes occur during data acquisition when computed tomography coronary angiography (CTCA) is performed with the prospectively ECG-triggered high-pitch (Flash spiral) mode using a second-generation dual-source CT. The aim of this study was to assess the effect of the ECG altered waves on image quality. Seventy-three consecutive patients with stable sinus rhythm ≤ 65 beats per minute were retrospectively enrolled in this study. CTCA was performed using the Flash spiral mode in which the data acquisition was prospectively triggered at 60 % of the R-R interval and completed within one cardiac cycle. The ECG waves before and during data acquisition were analyzed for grouping purposes. Image quality was evaluated using a four-point scale (1 = best, 4 = unevaluatable). Thirty patients (group 1) were found to have ECG altered waves during data acquisition, while 43 patients (group 2) had ECG "stable waves." The altered waves were seen as the baseline drifting; the broad, erected, or inverted P wave or QRS complexes; and a new wave. However, the length of the R-R interval did not change during the data acquisition. There were no significant differences in image quality scores between the two groups on the per-patient (2 ± 0.87 vs. 2.2 ± 0.74, P = 0.273) or per-segment (1.27 ± 0.54 vs. 1.32 ± 0.55, P = 0.577) basis. There were no significant differences in coronary evaluatability as well (per-patient; 93.3 vs. 95.3 %, P = 0.352; per-segment; 99.4 vs. 99.6 %, P = 1.0). CTCA image quality is not affected by ECG altered waves during data acquisition using the Flash spiral mode in low and stable heart rate patients. Thus, the ECG altered waves are considered artifacts.

  8. Image quality and radiation dose of dual-source CT cardiac angiography using prospective ECG-triggering technique in pediatric patients with congenital heart disease.

    PubMed

    Liu, Ying; Li, Jian; Zhao, Hongliang; Jia, Yan; Ren, Jing; Xu, Jian; Hao, Yuewen; Zheng, Minwen

    2016-04-09

    All studies involving use of ionizing radiation should be performed in accordance with the ALARA (As Low As Reasonably Achievable) principle, especially in children. In this study, the prospective ECG triggering technique with low voltage was used in dual-source computed tomography (DSCT) angiography to investigate if image quality with low radiation dose could be satisfactory in pediatric patients with congenital heart disease. Sixty pediatric patients with suspected congenital cardiovascular anomalies were enrolled prospectively in the study. They were randomly assigned to two groups for DSCT angiography. Group A were scanned by prospective ECG-triggering computed tomography angiography (CTA) with 80 kV tube voltage, while group B by used non-ECG-gated CTA with the same tube voltage. The anomaly accuracy was evaluated based on the surgical and/or conventional cardiac angiography findings. The overall image quality was assessed on a five-point scale. And the diagnostic accuracy and radiation dose was evaluated in both groups. There were 127 cardiovascular anomalies in Group A and 108 in Group B. The mean subjective image quality and diagnostic accuracy between these two groups were significantly different (P = 0.007 and 0.011, respectively). The mean effective dose in Group A and Group B was 0.38 ± 0.13 mSv and 0.35 ± 0.17 mSv, respectively. But there was no significant difference between two groups (P = 0.197). The prospective ECG triggering technique in DSCT scan can offer better image quality and diagnostic accuracy with low radiation exposure in pediatric patients with congenital heart diseases. This technique has potential to become a new clinical routine in pediatric cardiac computed tomography (CT) imaging.

  9. Coronary CT angiography with single-source and dual-source CT: comparison of image quality and radiation dose between prospective ECG-triggered and retrospective ECG-gated protocols.

    PubMed

    Sabarudin, Akmal; Sun, Zhonghua; Yusof, Ahmad Khairuddin Md

    2013-09-30

    This study is conducted to investigate and compare image quality and radiation dose between prospective ECG-triggered and retrospective ECG-gated coronary CT angiography (CCTA) with the use of single-source CT (SSCT) and dual-source CT (DSCT). A total of 209 patients who underwent CCTA with suspected coronary artery disease scanned with SSCT (n=95) and DSCT (n=114) scanners using prospective ECG-triggered and retrospective ECG-gated protocols were recruited from two institutions. The image was assessed by two experienced observers, while quantitative assessment was performed by measuring the image noise, the signal-to-noise ratio (SNR) and the contrast-to-noise ratio (CNR). Effective dose was calculated using the latest published conversion coefficient factor. A total of 2087 out of 2880 coronary artery segments were assessable, with 98.0% classified as of sufficient and 2.0% as of insufficient image quality for clinical diagnosis. There was no significant difference in overall image quality between prospective ECG-triggered and retrospective gated protocols, whether it was performed with DSCT or SSCT scanners. Prospective ECG-triggered protocol was compared in terms of radiation dose calculation between DSCT (6.5 ± 2.9 mSv) and SSCT (6.2 ± 1.0 mSv) scanners and no significant difference was noted (p=0.99). However, the effective dose was significantly lower with DSCT (18.2 ± 8.3 mSv) than with SSCT (28.3 ± 7.0 mSv) in the retrospective gated protocol. Prospective ECG-triggered CCTA reduces radiation dose significantly compared to retrospective ECG-gated CCTA, while maintaining good image quality. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  10. Testis of prepubertal rhesus monkeys receives a dual catecholaminergic input provided by the extrinsic innervation and an intragonadal source of catecholamines.

    PubMed

    Mayerhofer, A; Danilchik, M; Pau, K Y; Lara, H E; Russell, L D; Ojeda, S R

    1996-09-01

    regulatory domain of the enzyme. The cDNA that was obtained predicts an amino acid sequence similar, but not identical, to that encoded by the alternatively spliced type 1 TH mRNA form present in the adrenal gland. These results indicate 1) that the primate testis receives a dual catecholaminergic input, one provided by the extrinsic innervation and the other by neuron-like cells located within the gonad itself, and 2) that the influence exerted by both sources on testicular function may be more prominent during the prepubertal period than in adulthood. The presence in the testis of a TH mRNA variant encoding amino acid substitutions in its 5' end suggests that regulation of testicular TH enzyme activity may include a gonad-specific component.

  11. Free-breathing high-pitch 80kVp dual-source computed tomography of the pediatric chest: Image quality, presence of motion artifacts and radiation dose.

    PubMed

    Bodelle, Boris; Fischbach, Constanze; Booz, Christian; Yel, Ibrahim; Frellesen, Claudia; Beeres, Martin; Vogl, Thomas J; Scholtz, Jan-Erik

    2017-04-01

    To investigate image quality, presence of motion artifacts and effects on radiation dose of 80kVp high-pitch dual-source CT (DSCT) in combination with an advanced modeled iterative reconstruction algorithm (ADMIRE) of the pediatric chest compared to single-source CT (SSCT). The study was approved by the institutional review board. Eighty-seven consecutive pediatric patients (mean age 9.1±4.9years) received either free-breathing high-pitch (pitch 3.2) chest 192-slice DSCT (group 1, n=31) or standard-pitch (pitch 1.2) 128-slice SSCT (group 2, n=56) with breathing-instructions by random assignment. Tube settings were similar in both groups with 80 kVp and 74 ref. mAs. Images were reconstructed using FBP for both groups. Additionally, ADMIRE was used in group 1. Effective thorax diameter, image noise, and signal-to-noise ratio (SNR) of the pectoralis major muscle and the thoracic aorta were calculated. Motion artifacts were measured as doubling boarders of the diaphragm and the heart. Images were rated by two blinded readers for overall image quality and presence of motion artifacts on 5-point-scales. Size specific dose estimates (SSDE, mGy) and effective dose (ED, mSv) were calculated. Age and effective thorax diameter showed no statistically significant differences in both groups. Image noise and SNR were comparable (p>0.64) for SSCT and DSCT with ADMIRE, while DSCT with FBP showed inferior results (p<0.01). Motion artifacts were reduced significantly (p=0.001) with DSCT. DSCT with ADMIRE showed the highest overall IQ (p<0.0001). Radiation dose was lower for DSCT compared to SSCT (median SSDE: 0.82mGy vs. 0.92mGy, p<0.02; median ED: 0.4 mSv vs. 0.48mSv, p=0.02). High-pitch 80kVp chest DSCT in combination with ADMIRE reduces motion artifacts and increases image quality while lowering radiation exposure in free-breathing pediatric patients without sedation. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. 46 CFR 120.324 - Dual voltage generators.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Dual voltage generators. 120.324 Section 120.324... INSTALLATION Power Sources and Distribution Systems § 120.324 Dual voltage generators. (a) A dual voltage generator installed on a vessel shall be of the grounded type, where: (1) The neutral of a dual voltage...

  13. 46 CFR 120.324 - Dual voltage generators.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Dual voltage generators. 120.324 Section 120.324... INSTALLATION Power Sources and Distribution Systems § 120.324 Dual voltage generators. (a) A dual voltage generator installed on a vessel shall be of the grounded type, where: (1) The neutral of a dual voltage...

  14. 46 CFR 120.324 - Dual voltage generators.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Dual voltage generators. 120.324 Section 120.324... INSTALLATION Power Sources and Distribution Systems § 120.324 Dual voltage generators. (a) A dual voltage generator installed on a vessel shall be of the grounded type, where: (1) The neutral of a dual voltage...

  15. 46 CFR 120.324 - Dual voltage generators.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Dual voltage generators. 120.324 Section 120.324... INSTALLATION Power Sources and Distribution Systems § 120.324 Dual voltage generators. (a) A dual voltage generator installed on a vessel shall be of the grounded type, where: (1) The neutral of a dual voltage...

  16. 46 CFR 120.324 - Dual voltage generators.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Dual voltage generators. 120.324 Section 120.324... INSTALLATION Power Sources and Distribution Systems § 120.324 Dual voltage generators. (a) A dual voltage generator installed on a vessel shall be of the grounded type, where: (1) The neutral of a dual voltage...

  17. 46 CFR 129.326 - Dual-voltage generators.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Dual-voltage generators. 129.326 Section 129.326... INSTALLATIONS Power Sources and Distribution Systems § 129.326 Dual-voltage generators. If a dual-voltage generator is installed on an OSV— (a) The neutral of the dual-voltage system must be solidly grounded at the...

  18. 46 CFR 129.326 - Dual-voltage generators.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false Dual-voltage generators. 129.326 Section 129.326... INSTALLATIONS Power Sources and Distribution Systems § 129.326 Dual-voltage generators. If a dual-voltage generator is installed on an OSV— (a) The neutral of the dual-voltage system must be solidly grounded at the...

  19. 46 CFR 129.326 - Dual-voltage generators.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false Dual-voltage generators. 129.326 Section 129.326... INSTALLATIONS Power Sources and Distribution Systems § 129.326 Dual-voltage generators. If a dual-voltage generator is installed on an OSV— (a) The neutral of the dual-voltage system must be solidly grounded at the...

  20. 46 CFR 129.326 - Dual-voltage generators.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false Dual-voltage generators. 129.326 Section 129.326... INSTALLATIONS Power Sources and Distribution Systems § 129.326 Dual-voltage generators. If a dual-voltage generator is installed on an OSV— (a) The neutral of the dual-voltage system must be solidly grounded at the...

  1. 46 CFR 129.326 - Dual-voltage generators.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Dual-voltage generators. 129.326 Section 129.326... INSTALLATIONS Power Sources and Distribution Systems § 129.326 Dual-voltage generators. If a dual-voltage generator is installed on an OSV— (a) The neutral of the dual-voltage system must be solidly grounded at the...

  2. Comparison of corneal power, astigmatism, and wavefront aberration measurements obtained by a point-source color light-emitting diode-based topographer, a Placido-disk topographer, and a combined Placido and dual Scheimpflug device.

    PubMed

    Ventura, Bruna V; Wang, Li; Ali, Shazia F; Koch, Douglas D; Weikert, Mitchell P

    2015-08-01

    To evaluate and compare the performance of a point-source color light-emitting diode (LED)-based topographer (color-LED) in measuring anterior corneal power and aberrations with that of a Placido-disk topographer and a combined Placido and dual Scheimpflug device. Cullen Eye Institute, Baylor College of Medicine, Houston, Texas USA. Retrospective observational case series. Normal eyes and post-refractive-surgery eyes were consecutively measured using color-LED, Placido, and dual-Scheimpflug devices. The main outcome measures were anterior corneal power, astigmatism, and higher-order aberrations (HOAs) (6.0 mm pupil), which were compared using the t test. There were no statistically significant differences in corneal power measurements in normal and post-refractive surgery eyes and in astigmatism magnitude in post-refractive surgery eyes between the color-LED device and Placido or dual Scheimpflug devices (all P > .05). In normal eyes, there were no statistically significant differences in 3rd-order coma and 4th-order spherical aberration between the color-LED and Placido devices and in HOA root mean square, 3rd-order coma, 3rd-order trefoil, 4th-order spherical aberration, and 4th-order secondary astigmatism between the color-LED and dual Scheimpflug devices (all P > .05). In post-refractive surgery eyes, the color-LED device agreed with the Placido and dual-Scheimpflug devices regarding 3rd-order coma and 4th-order spherical aberration (all P > .05). In normal and post-refractive surgery eyes, all 3 devices were comparable with respect to corneal power. The agreement in corneal aberrations varied. Drs. Wang, Koch, and Weikert are consultants to Ziemer Ophthalmic Systems AG. Dr. Koch is a consultant to Abbott Medical Optics, Inc., Alcon Surgical, Inc., and i-Optics Corp. Copyright © 2015 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  3. Using dual temperature difference two source energy balance model and MODIS data to estimate surface energy fluxes at regional scales in northern latitudes

    NASA Astrophysics Data System (ADS)

    Guzinski, R.; Anderson, M.; Kustas, W.; Nieto, H.; Sandholt, I.

    2012-04-01

    A Two Source Energy Balance (TSEB) thermal-based modeling scheme has previously been used to successfully estimate surface latent and sensible heat fluxes at regional to continental scales with the help of satellite surface radiometric temperature observations. The Dual Temperature Difference (DTD) model introduced a simple methodology to address the sensitivity of the thermal-based energy balance models to the absolute measurement of land surface temperature (LST), which when derived with the help of satellites can have errors of several degrees. The original DTD model formulation required an early morning LST observation (1 hour after local sunrise) when fluxes were minimal followed by another LST observations later in the morning or afternoon and so was limited in use to data provided by geostationary satellites having high temporal resolution. This, however, made it unsuitable for areas at higher latitudes, such as northern Eurasia and northern North America. In this poster we present a number of modifications to the DTD model which allows it to exploit the day and night LST observations by the MODIS sensor aboard the Terra and Aqua polar orbiting satellites. Firstly, we look at whether taking the first LST observation around the time of Aqua's night overpass, when fluxes are small but not insignificant, would greatly affect the accuracy of the model. Secondly, we consider the issues directly related to using the MODIS sensor to measure the LST. This includes different view zenith angles of the day and night LST observations, the two observations possibly coming from the two different satellites and the accuracy of the instrument itself. We also evaluate two approaches for estimating αPT, the Priestley-Taylor parameter used in the TSEB modeling scheme to estimate heat fluxes of the vegetation canopy, to improve the performance of the model in coniferous and deciduous forests. The first approach estimates αPT based on tree height, while the second uses

  4. Application of prospective ECG-triggered dual-source CT coronary angiography for infants and children with coronary artery aneurysms due to Kawasaki disease

    PubMed Central

    Duan, Y; Wang, X; Cheng, Z; Wu, D; Wu, L

    2012-01-01

    Objectives The aim of this study was to prospectively evaluate the initial application and value of prospective electrocardiogram (ECG)-triggered dual-source CT coronary angiography (DSCTCA) in the diagnosis of infants and children with coronary artery aneurysms due to Kawasaki disease. Methods 19 children [12 males; mean age 13.47 months, range 3 months to 5 years; mean heart rate 112 beats per minute (bpm), range 83–141 bpm] underwent prospective ECG-triggered DSCTCA with free breathing. Subjective image quality was assessed on a five-point scale (1, excellent; 5, non-diagnostic) by two blinded observers. The location, number and size of each aneurysm were observed and compared with those of transthoracic echocardiography (TTE) performed within 1 week. Interobserver agreement concerning the subjective image quality was evaluated with Cohen's κ-test. Bland–Altman analysis was used to evaluate the agreement on measurements (diameter and length of aneurysms) between DSCTCA and TTE. The average effective dose required for DSCTCA was calculated for all children. Results All interobserver agreement for subjective image quality assessment was excellent (κ=0.87). The mean±standard deviation (SD) aneurysm diameter with DSCTCA was 0.76±0.36 cm and with TTE was 0.76±0.39 cm. The mean±SD aneurysm length with DSCTCA was 2.06±1.35 cm and with TTE was 2.00±1.22 cm. The Bland–Altman plot for agreement between DSCTCA and TTE measurements showed good agreement. The mean effective dose was 0.36±0.06 mSv. Conclusion As an alternative diagnostic modality, prospective ECG-triggered DSCTCA with excellent image quality and low radiation exposure has been proved useful for diagnosing infants and children with coronary artery aneurysms due to Kawasaki disease. Advances in knowledge Prospective ECG–triggered DSCTCA for infants and children allows rapid, accurate assessment of coronary aneurysms due to Kawasaki diseases, compared with TTE. PMID:22932064

  5. Application of the Low-dose One-stop-shop Cardiac CT Protocol with Third-generation Dual-source CT.

    PubMed

    Lin, Lu; Wang, Yining; Yi, Yan; Cao, Jian; Kong, Lingyan; Qian, Hao; Zhang, Hongzhi; Wu, Wei; Wang, Yun; Jin, Zhengyu

    2017-02-20

    Objective To evaluate the feasibility of a low-dose one-stop-shop cardiac CT imaging protocol with third-generation dual-source CT (DSCT). Methods Totally 23 coronary artery disease (CAD) patients were prospectively enrolled between March to September in 2016. All patients underwent an ATP stress dynamic myocardial perfusion imaging (MPI) (data acquired prospectively ECG-triggered during end systole by table shuttle mode in 32 seconds) at 70 kV combined with prospectively ECG-triggered high-pitch coronary artery angiography (CCTA) on a third-generation DSCT system. Myocardial blood flow (MBF) was quantified and compared between perfusion normal and abnormal myocardial segments based on AHA-17-segment model. CCTA images were evaluated qualitatively based on SCCT-18-segment model and the effective dose(ED) was calculated. In patients with subsequent catheter coronary angiography (CCA) as reference,the diagnosis performance of MPI (for per-vessel ≥50% and ≥70% stenosis) and CCTA (for≥50% stenosis) were assessed. Results Of 23 patients who had completed the examination of ATP stress MPI plus CCTA,12 patients received follow-up CCA. At ATP stress MPI,77 segments (19.7%) in 13 patients (56.5%) had perfusion abnormalities. The MBF values of hypo-perfused myocardial segments decreased significantly compared with normal segments [(93±22)ml/(100 ml·min) vs. (147±27)ml/(100 ml·min);t=15.978,P=0.000]. At CCTA,93.9% (308/328) of the coronary segments had diagnostic image quality. With CCA as the reference standard,the per-vessel and per-segment sensitivity,specificity,and accuracy of CCTA for stenosis≥50% were 94.1%,93.5%,and 93.7% and 90.9%,97.8%,and 96.8%,and the per-vessel sensitivity,specificity and accuracy of ATP stress MPI for stenosis≥50% and ≥70% were 68.7%,100%,and 89.5% and 91.7%,100%,and 97.9%. The total ED of MPI and CCTA was (3.9±1.3) mSv [MPI:(3.5±1.2) mSv,CCTA:(0.3±0.1) mSv]. Conclusion The third-generation DSCT stress dynamic MPI at 70 k

  6. Influence of trigger type, tube voltage and heart rate on calcified plaque imaging in dual source cardiac computed tomography: phantom study

    PubMed Central

    2014-01-01

    Background To investigate the impact of high pitch cardiac CT vs. retrospective ECG gated CT on the quantification of calcified vessel stenoses, with assessment of the influence of tube voltage, reconstruction kernel and heart rate. Methods A 4D cardiac movement phantom equipped with three different plaque phantoms (12.5%, 25% and 50% stenosis at different calcification levels), was scanned with a 128-row dual source CT scanner, applying different trigger types (gated vs. prospectively triggered high pitch), tube voltages (100-120 kV) and heart rates (50–90 beats per minute, bpm). Images were reconstructed using different standard (B26f, B46f, B70f) and iterative (I26f, I70f) convolution kernels. Absolute and relative plaque sizes were measured and statistically compared. Radiation dose associated with the different methods (gated vs. high pitch, 100 kV vs. 120 kV) were compared. Results Compared to the known diameters of the phantom plaques and vessels both CT-examination techniques overestimated the degrees of stenoses. Using the high pitch CT-protocol plaques appeared larger (0.09 ± 0.31 mm, 2 ± 8 percent points, PP) in comparison to the ECG-gated CT-scans. Reducing tube voltage had a similar effect, resulting in higher grading of the same stenoses by 3 ± 8 PP. In turn, sharper convolution kernels lead to a lower grading of stenoses (differences of up to 5%). Pairwise comparison of B26f and I26f, B46f and B70f, and B70f and I70f showed differences of 0–1 ± 6–8 PP of the plaque depiction. Motion artifacts were present only at 90 bpm high pitch experiments. High-pitch protocols were associated with significantly lower radiation doses compared with the ECG-gated protocols (258.0 mGy vs. 2829.8 mGy CTDIvol, p ≤ 0.0001). Conclusion Prospectively triggered high-pitch cardiac CT led to an overestimation of plaque diameter and degree of stenoses in a coronary phantom. This overestimation is only slight and probably negligible in a

  7. Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate control

    PubMed Central

    Scheffel, Hans; Plass, André; Vachenauer, Robert; Desbiolles, Lotus; Gaemperli, Oliver; Schepis, Tiziano; Frauenfelder, Thomas; Schertler, Thomas; Husmann, Lars; Grunenfelder, Jürg; Genoni, Michele; Kaufmann, Philipp A.; Marincek, Borut; Leschka, Sebastian

    2006-01-01

    The aim of this study was to assess the diagnostic accuracy of dual-source computed tomography (DSCT) for evaluation of coronary artery disease (CAD) in a population with extensive coronary calcifications without heart rate control. Thirty patients (24 male, 6 female, mean age 63.1±11.3 years) with a high pre-test probability of CAD underwent DSCT coronary angiography and invasive coronary angiography (ICA) within 14±9 days. No beta-blockers were administered prior to the scan. Two readers independently assessed image quality of all coronary segments with a diameter ≥1.5 mm using a four-point score (1: excellent to 4: not assessable) and qualitatively assessed significant stenoses as narrowing of the luminal diameter >50%. Causes of false-positive (FP) and false-negative (FN) ratings were assigned to calcifications or motion artifacts. ICA was considered the standard of reference. Mean body mass index was 28.3±3.9 kg/m2 (range 22.4–36.3 kg/m2), mean heart rate during CT was 70.3±14.2 bpm (range 47–102 bpm), and mean Agatston score was 821±904 (range 0–3,110). Image quality was diagnostic (scores 1–3) in 98.6% (414/420) of segments (mean image quality score 1.68±0.75); six segments in three patients were considered not assessable (1.4%). DSCT correctly identified 54 of 56 significant coronary stenoses. Severe calcifications accounted for false ratings in nine segments (eight FP/one FN) and motion artifacts in two segments (one FP/one FN). Overall sensitivity, specificity, positive and negative predictive value for evaluating CAD were 96.4, 97.5, 85.7, and 99.4%, respectively. First experience indicates that DSCT coronary angiography provides high diagnostic accuracy for assessment of CAD in a high pre-test probability population with extensive coronary calcifications and without heart rate control. PMID:17031451

  8. Inter-scan variability of coronary artery calcium scoring assessed on 64-multidetector computed tomography vs. dual-source computed tomography: a head-to-head comparison.

    PubMed

    Ghadri, Jelena R; Goetti, Robert; Fiechter, Michael; Pazhenkottil, Aju P; Küest, Silke M; Nkoulou, Rene N; Windler, Christina; Buechel, Ronny R; Herzog, Bernhard A; Gaemperli, Oliver; Templin, Christian; Kaufmann, Philipp A

    2011-08-01

    Coronary artery calcium (CAC) scoring has emerged as a tool for risk stratification and potentially for monitoring response to risk factor modification. Therefore, repeat measurements should provide robust results and low inter-scanner variability for allowing meaningful comparison. The purpose of this study was to investigate inter-scanner variability of CAC for Agatston, volume, and mass scores by head-to-head comparison using two different cardiac computed tomography scanners: 64-detector multislice CT (MSCT) and 64-slice dual-source CT (DSCT). Thirty patients underwent CAC measurements on both 64-MSCT (GE LightSpeed XT scanner: 120 kV, 70 mAs, 2.5 mm slices) and 64-DSCT (Siemens Somatom Definition: 120 kV, 80 mAs, 3 mm slices) within <100 days (0-97). Retrospective intra-scan comparison revealed an excellent correlation. The excellent intra-scan (inter-observer) agreement was documented by narrow limits of agreement and a correlation coefficient of variation (COV) of r ≥ 0.99 (P < 0.001) for all CAC scores with a low COV for both scanners (64-MSCT/64-DSCT), i.e. Agatston (2.0/2.1%), mass (3.0/2.0%), and volume (4.7/3.9%). Inter-scanner comparison revealed larger Bland-Altman (BA) limits of agreement, despite high correlation (r ≥ 0.97) for all scores, with COV at 15.1, 21.6, and 44.9% for Agatston, mass, and volume scores. The largest BA limits were observed for volume scores (-1552.8 to 574.2), which was massively improved (-241.0 to 300.4, COV 11.5%) after reanalysing the 64-DSCT scans (Siemens) with GE software/workstation (while Siemens software/workstation does not allow cross-vendor analysis). Phantom measurements confirmed overestimation of volume scores by 'syngo Ca-Scoring' (Siemens) software which should therefore be reviewed (vendor has been notified). Intra- and inter-scan agreement of CAC measurement in a given data set is excellent. Inter-scanner variability is reasonable, particularly for Agatston units in the clinically most relevant range

  9. Identification of dissolved sulfate sources and the role of sulfuric acid in carbonate weathering using dual-isotopic data from the Jialing River, Southwest China

    NASA Astrophysics Data System (ADS)

    Li, Xiao-Dong; Liu, Cong-Qiang; Liu, Xiao-Long; Bao, Li-Ran

    2011-08-01

    Rock weathering by carbonic acid has played a substantial role in both the global carbon cycle and related climate change. Carbonic acid as the major weathering agent has been accepted, whereas the importance of other acid (sulfuric, nitric or organic acids) as an agent is gradually recognized. Here, we examine sulfate dual-isotopic evidence ( δ34S and δ18O) and water chemistry from the Jialing River (Sichuan Basin, Southwest China) to identify dissolved sulfate sources and the role of sulfuric acid in carbonate weathering. A survey was carried out at 29 sites where surface water was sampled during the rainy (July, 2008) and dry (February, 2009) seasons in the Jialing River. The chemical composition of river water was characterized by a dominance of Ca 2+, Mg 2+ and HCO3-, and SO42-, which accounted for more than 90% of the total ion concentrations. Water chemistry varied greatly in time and space, particularly for Na +, Cl -, and SO42-. This variation was a result of anthropogenic influences, such as acid deposition and domestic sewage inputs. Co-variation of the equivalent ratios of [Ca 2+ + Mg 2+] and [ SO42- + HCO3-] indicate that it required significant additional SO42- to achieve ionic balance, which implied that sulfuric acid might play a relatively important role in carbonate weathering of this river basin. Water samples from the Jialing River were significantly rich in SO42-, and increased almost two times from 274 μM in the period of 1958-1990 to 499 μM in this study. The use of co-variations of δ34Svs. δ18O and of δ18Ovs. δ18OO allowed us to demonstrate that most of the sulfate in the waters of the Jialing River was derived from sulfide oxidation and atmospheric inputs by high sulfur-content coal combustion while the contribution of sulfate from domestic and industrial wastewater could be important in the dry season. Thus, the contribution of sulfuric acid, produced by such sulfide oxidation and the oxidation of atmospheric SO 2 emitted from coal

  10. Focal liver lesions at 3.0 T: lesion detectability and image quality with T2-weighted imaging by using conventional and dual-source parallel radiofrequency transmission.

    PubMed

    Kukuk, Guido M; Gieseke, Jürgen; Weber, Sebastian; Hadizadeh, Dariusch R; Nelles, Michael; Träber, Frank; Schild, Hans H; Willinek, Winfried A

    2011-05-01

    To prospectively compare T2-weighted single-shot turbo spin-echo (TSE) sequences performed with parallel and conventional radiofrequency (RF) transmission at 3.0 T for liver lesion detection, image quality, lesion conspicuity, and lesion contrast. After written informed consent and institutional review board approval, 52 consecutive patients (32 men, 20 women; mean age, 56.6 years ± 13.7 [standard deviation]) underwent routine magnetic resonance (MR) imaging with a clinical 3.0-T unit. Two independent readers reviewed images acquired with conventional and dual-source parallel RF transmission for detection of focal liver lesions, with separate reading of a third radiologist, including all available imaging findings, clinical history, and histopathologic findings, as reference. Image quality and lesion conspicuity were rated on five- and three-point evaluation scales, respectively. Contrast ratios between focal liver lesions and adjacent liver parenchyma were calculated. Significance was determined by using nonparametric Wilcoxon signed-rank and marginal homogeneity tests. With the reference standard, 106 index lesions were identified in 22 patients. Detection rate significantly improved from 87% (92 of 106) to 97% (103 of 106) (reader 1) and from 85% (90 of 106) to 96% (102 of 106) (reader 2) with parallel RF transmission (reader 1, P = .0078; reader 2, P = .002). Quality of parallel RF transmission images was assigned scores significantly higher, compared with quality of conventional RF transmission images (mean for reader 1, 2.88 ± 0.73 vs 4.04 ± 0.44; mean for reader 2, 2.81 ± 0.72 vs 4.04 ± 0.39; P < .0001 for both). Lesion conspicuity scores were significantly higher on parallel RF transmission images, compared with conventional RF transmission images (mean for reader 1, 2.02 ± 0.64 vs 2.92 ± 0.27; mean for reader 2, 2.06 ± 0.67 vs 2.90 ± 0.30; P < .0001 for both). Contrast ratios were significantly higher with parallel RF transmission (P < .05

  11. [Study of low radiation exposure dose and low contrast medium dose in coronary CT angiography with High-pitch spiral acquisition mode of dual source CT].

    PubMed

    Dai, Yingyu; Guo, Liang; Dai, Qichun; Liu, Yonghao; Ma, Xinxing

    2014-08-05

    To evaluate the feasibility of low radiation exposure and low contrast medium volume for coronary CT angiography with High- pitch spiral acquisition mode of dual source CT. 135 patients whose BMI <23 kg/m² and heart rates <65 bpm selected from 291 patients diagnosed of suspected CHD at our institution from September 2013 to February 2014 were randomly divided into 3 groups before CCTA, and there were 45 patients in each group. 80 kV , Iodixanol (320 mgI/ml) and sinogram affirmed iterative reconstruction (SAFIRE) were used in A group. 80 kV , Iopamidol (370 mgI/ml) and SAFIRE were used in B group. 100 kV, Iodixanol and filtered back projection (FBP) were used in C group. Two radiologists assessed image quality with 5-piont scale subjectively and double-blind. Independent-Sample Test was used to analyze statistical significance of image quality including signal to noise ratio(SNR) and contrast to noise ratio (CNR) between A and B group or between A and C group. At the same time, Contrast medium dose statistical significance between A and B group and mean effective Radiation dose (ED)statistical significance between A and C were analyzed by the same way. There were no significant difference of image quality including SNR and CNR of aortic root (AO), left main coronary artery (LM), left anterior descending artery (LAD), circumflex coronary artery (CX) and right coronary artery (RCA) Between A and B group (P = non-significant for all comparison), whereas Iodine in taken of A group decreased 14% (17 600 mg vs 20 350 mg). There were no significant difference of image quality including SNR and CNR of AO, LM, LAD, CX and RCA Between A and C group (P = non-significant for all comparison), whereas mean ED of A group decreased 50% (0.41 ± 0.05 mSv vs 0.79 ± 0.15 mSv). The double low dose application which use High-pitch spiral mode, 80 kV, SAFIRE, and Iodixanol (320 mgI/ml) can be used in those patients whose BMI <23 kg/m² and heart rates <65 bpm to reduce the burden of

  12. Using nitrate dual isotopic composition (δ15N and δ18O) as a tool for exploring sources and cycling of nitrate in an estuarine system: Elkhorn Slough, California

    USGS Publications Warehouse

    Wankel, Scott D.; Kendall, Carol; Paytan, Adina

    2009-01-01

    Nitrate (NO-3 concentrations and dual isotopic composition (??15N and ??18O) were measured during various seasons and tidal conditions in Elkhorn Slough to evaluate mixing of sources of NO-3 within this California estuary. We found the isotopic composition of NO-3 was influenced most heavily by mixing of two primary sources with unique isotopic signatures, a marine (Monterey Bay) and terrestrial agricultural runoff source (Old Salinas River). However, our attempt to use a simple two end-member mixing model to calculate the relative contribution of these two NO-3 sources to the Slough was complicated by periods of nonconservative behavior and/or the presence of additional sources, particularly during the dry season when NO-3 concentrations were low. Although multiple linear regression generally yielded good fits to the observed data, deviations from conservative mixing were still evident. After consideration of potential alternative sources, we concluded that deviations from two end-member mixing were most likely derived from interactions with marsh sediments in regions of the Slough where high rates of NO-3 uptake and nitrification result in NO-3 with low ?? 15N and high ??18O values. A simple steady state dual isotope model is used to illustrate the impact of cycling processes in an estuarine setting which may play a primary role in controlling NO -3 isotopic composition when and where cycling rates and water residence times are high. This work expands our understanding of nitrogen and oxygen isotopes as biogeochemical tools for investigating NO -3 sources and cycling in estuaries, emphasizing the role that cycling processes may play in altering isotopic composition. Copyright 2009 by the American Geophysical Union.

  13. Using nitrate dual isotopic composition (δ15N and δ18O) as a tool for exploring sources and cycling of nitrate in an estuarine system: Elkhorn Slough, California

    NASA Astrophysics Data System (ADS)

    Wankel, Scott D.; Kendall, Carol; Paytan, Adina

    2009-03-01

    Nitrate (NO3-) concentrations and dual isotopic composition (δ15N and δ18O) were measured during various seasons and tidal conditions in Elkhorn Slough to evaluate mixing of sources of NO3- within this California estuary. We found the isotopic composition of NO3- was influenced most heavily by mixing of two primary sources with unique isotopic signatures, a marine (Monterey Bay) and terrestrial agricultural runoff source (Old Salinas River). However, our attempt to use a simple two end-member mixing model to calculate the relative contribution of these two NO3- sources to the Slough was complicated by periods of nonconservative behavior and/or the presence of additional sources, particularly during the dry season when NO3- concentrations were low. Although multiple linear regression generally yielded good fits to the observed data, deviations from conservative mixing were still evident. After consideration of potential alternative sources, we concluded that deviations from two end-member mixing were most likely derived from interactions with marsh sediments in regions of the Slough where high rates of NO3- uptake and nitrification result in NO3- with low δ15N and high δ18O values. A simple steady state dual isotope model is used to illustrate the impact of cycling processes in an estuarine setting which may play a primary role in controlling NO3- isotopic composition when and where cycling rates and water residence times are high. This work expands our understanding of nitrogen and oxygen isotopes as biogeochemical tools for investigating NO3- sources and cycling in estuaries, emphasizing the role that cycling processes may play in altering isotopic composition.

  14. Neural Correlates of Confidence during Item Recognition and Source Memory Retrieval: Evidence for Both Dual-Process and Strength Memory Theories

    ERIC Educational Resources Information Center

    Hayes, Scott M.; Buchler, Norbou; Stokes, Jared; Kragel, James; Cabeza, Roberto

    2011-01-01

    Although the medial-temporal lobes (MTL), PFC, and parietal cortex are considered primary nodes in the episodic memory network, there is much debate regarding the contributions of MTL, PFC, and parietal subregions to recollection versus familiarity (dual-process theory) and the feasibility of accounts on the basis of a single memory strength…

  15. Neural Correlates of Confidence during Item Recognition and Source Memory Retrieval: Evidence for Both Dual-Process and Strength Memory Theories

    ERIC Educational Resources Information Center

    Hayes, Scott M.; Buchler, Norbou; Stokes, Jared; Kragel, James; Cabeza, Roberto

    2011-01-01

    Although the medial-temporal lobes (MTL), PFC, and parietal cortex are considered primary nodes in the episodic memory network, there is much debate regarding the contributions of MTL, PFC, and parietal subregions to recollection versus familiarity (dual-process theory) and the feasibility of accounts on the basis of a single memory strength…

  16. System Design as a Three-Phase Dual-Loop (TPDL) Process: Types of Knowledge-Applied Sources of Feedback, and Student Development as Independent Learners

    ERIC Educational Resources Information Center

    Barak, Moshe

    2010-01-01

    This study aimed at exploring how high school students deal with designing an information system, for example, for a small business or a medical clinic, the extent to which students develop as independent learners while working on their projects, and the factors that help or hinder fostering students' design skills. The three-phase dual-loop…

  17. Third-generation Dual-source CT for Head and Neck CT Angiography with 70 kV Tube Voltage and 20-25 ml Contrast Medium in Patients With Body Weight Lower than 75 kg.

    PubMed

    Chen, Yu; Zhu, Yuanli; Xue, Huadan; Wang, Yun; Li, Yumei; Zhang, Zhuhua; Jin, Zhengyu

    2017-02-20

    Objective To investigate the image quality of head and neck CT angiography (CTA)using the third-generation dual-source CT combined with 70 kV tube voltage and 20-25 ml contrast medium (CM),and evaluate the effects of venous artifacts arising from the CM on the ipsilateral side of injection. Methods Totally 40 consecutive patients with suspected vascular diseases and body weight lower than 75 kg prospectively underwent head and neck CTA examination using the third-generation dual-source CT. CTA was performed with a third-generation dual-source CT system. Patients were randomly divived into 70 kV group (n=20)and 100 kV group (n=20). The 70 kV group used 20-25 ml CM and advanced modeled iterative reconstruction technique,and the 100 kV group used 40 ml CM and filtered back projection. Venous artifacts and CM residues were evaluated by a 3-point scale (1=excellent,3=poor),respectively. Results The effective dose of 70 kV group decreased 58% compared to 100 kV group (t=-18.14,P<0.001).In the 70 kV group,16 patients (80.0%)presented with venous artifacts and six of them (37.5%,6/16)affected the adjacent arteries. In the 100 kV group,19 patients (95.0%)presented with venous artifacts,and seven of them (36.8%,7/19)affected the adjacent arteries (Z=-0.878,P=0.380). In the 70 kV group,13 patients (65.0%)presented with obvious CM residues and two of them (15.3%,2/13)prolonged into the superior vena cava (SVC). In the 100 kV group,19 patients(95.0%)presented with obvious CM residues,and thirteen of them(68.4%,13/19)prolonged into the SVC (Z=-3.654,P<0.001). Conclusion Compared with the 100 kV,the third-generation dual-source CT for head and neck CTA,combined with 70 kV and 20-25 ml CM,can remarkably decrease the radiation dose,along with reduced CM residues and comparable venous artifacts.

  18. Identifying nitrate sources and transformations in surface water by combining dual isotopes of nitrate and stable isotope mixing model in a watershed with different land uses and multi-tributaries

    NASA Astrophysics Data System (ADS)

    Wang, Meng; Lu, Baohong

    2017-04-01

    Nitrate is essential for the growth and survival of plants, animals and humans. However, excess nitrate in drinking water is regarded as a health hazard as it is linked to infant methemoglobinemia and esophageal cancer. Revealing nitrate characteristics and identifying its sources are fundamental for making effective water management strategies, but nitrate sources in multi-tributaries and mixed land covered watersheds remain unclear. It is difficult to determine the predominant NO3- sources using conventional water quality monitoring techniques. In our study, based on 20 surface water sampling sites for more than two years' monitoring from April 2012 to December 2014, water chemical and dual isotopic approaches (δ15N-NO3- and δ18O-NO3-) were integrated for the first time to evaluate nitrate characteristics and sources in the Huashan watershed, Jianghuai hilly region, East China. The results demonstrated that nitrate content in surface water was relatively low in the downstream (<10 mg/L), but spatial heterogeneities were remarkable among different sub-watersheds. Extremely high nitrate was observed at the source of the river in one of the sub-watersheds, which exhibited an exponential decline along the stream due to dilution, absorption by aquatic plants, and high forest cover. Although dramatically decline of nitrate occurred along the stream, denitrification was not found in surface water by analyzing δ15N-NO3- and δ18O-NO3- relationship. Proportional contributions of five potential nitrate sources (i.e., precipitation; manure and sewage; soil nitrogen; nitrate fertilizer; nitrate derived from ammonia fertilizer and rainfall) were estimated using a Bayesian isotope mixing model. Model results indicated nitrate sources varied significantly among different rainfall conditions, land use types, as well as anthropologic activities. In summary, coupling dual isotopes of nitrate (δ15N-NO3- and δ18O-NO3-, simultaneously) with a Bayesian isotope mixing model offers

  19. Mid-infrared difference-frequency generation source pumped by 1.1-1.5 micrometer dual-wavelength fiber amplifier for trace-gas detection

    NASA Technical Reports Server (NTRS)

    Goldberg, L.; Koplow, J.; Lancaster, D. G.; Curl, R. F.; Tittel, F. K.

    1998-01-01

    Continuous-wave mid-infrared radiation near 3.5 micrometers is generated by difference-frequency mixing of the output of a compact 1.1-1.5 micrometer dual-wavelength fiber amplifier in periodically poled LiNbO3. The diode side-pumped amplifier is constructed with double-cladding Yb-doped fiber followed by single-mode Er/Yb codoped fiber. Output powers of as much as 11 microW at 3.4 micrometers are obtained, and spectroscopic detection of CH4 and H2CO is demonstrated. c 1998 Optical Society of America.

  20. Size- and morphology-controllable synthesis of MIL-96 (Al) by hydrolysis and coordination modulation of dual aluminium source and ligand systems.

    PubMed

    Liu, Dandan; Liu, Yunqi; Dai, Fangna; Zhao, Jinchong; Yang, Kang; Liu, Chenguang

    2015-10-07

    In this paper, an efficient method to fabricate Al-based metal organic framework (Al-MOF) MIL-96 crystals with controllable size and morphology, by mixing other forms of reactants to replace the coordination modulators or capping agents, is presented. The size and morphology of the MIL-96 crystals can be selectively varied by simply altering the ratio of dual reactants via their hydrolysis reaction. All the samples were characterized by X-ray powder diffraction (XRD), scanning electron microscopy (SEM), Fourier Transform Infrared (FT-IR) spectroscopy, thermogravimetric analysis (TGA) and nitrogen sorption. Then based on the BFDH theory, a mechanism for the impact of hydrolysis of reactants on the crystal size and morphology is presented and discussed. We also evaluated the performance of these MOFs as sorbents for capturing CO2, and they all show enhanced adsorption properties compared with the bulk material, displaying high adsorption capacities on CO2 at atmospheric pressure and ambient temperature.

  1. Estimation and comparison of effective dose (E) in standard chest CT by organ dose measurements and dose-length-product methods and assessment of the influence of CT tube potential (energy dependency) on effective dose in a dual-source CT.

    PubMed

    Paul, Jijo; Banckwitz, Rosemarie; Krauss, Bernhard; Vogl, Thomas J; Maentele, Werner; Bauer, Ralf W

    2012-04-01

    To determine effective dose (E) during standard chest CT using an organ dose-based and a dose-length-product-based (DLP) approach for four different scan protocols including high-pitch and dual-energy in a dual-source CT scanner of the second generation. Organ doses were measured with thermo luminescence dosimeters (TLD) in an anthropomorphic male adult phantom. Further, DLP-based dose estimates were performed by using the standard 0.014mSv/mGycm conversion coefficient k. Examinations were performed on a dual-source CT system (Somatom Definition Flash, Siemens). Four scan protocols were investigated: (1) single-source 120kV, (2) single-source 100kV, (3) high-pitch 120kV, and (4) dual-energy with 100/Sn140kV with equivalent CTDIvol and no automated tube current modulation. E was then determined following recommendations of ICRP publication 103 and 60 and specific k values were derived. DLP-based estimates differed by 4.5-16.56% and 5.2-15.8% relatively to ICRP 60 and 103, respectively. The derived k factors calculated from TLD measurements were 0.0148, 0.015, 0.0166, and 0.0148 for protocol 1, 2, 3 and 4, respectively. Effective dose estimations by ICRP 103 and 60 for single-energy and dual-energy protocols show a difference of less than 0.04mSv. Estimates of E based on DLP work equally well for single-energy, high-pitch and dual-energy CT examinations. The tube potential definitely affects effective dose in a substantial way. Effective dose estimations by ICRP 103 and 60 for both single-energy and dual-energy examinations differ not more than 0.04mSv. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  2. 46 CFR 183.324 - Dual voltage generators.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... TONS) ELECTRICAL INSTALLATION Power Sources and Distribution Systems § 183.324 Dual voltage generators... neutral of a dual voltage system must be solidly connected at the switchboard's neutral bus; and (2) The neutral bus shall be connected to ground. (b) The neutral of a dual voltage system must be accessible for...

  3. 46 CFR 183.324 - Dual voltage generators.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Dual voltage generators. 183.324 Section 183.324... TONS) ELECTRICAL INSTALLATION Power Sources and Distribution Systems § 183.324 Dual voltage generators. (a) A dual voltage generator installed on a vessel shall be of the grounded type, where: (1) The...

  4. 46 CFR 183.324 - Dual voltage generators.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Dual voltage generators. 183.324 Section 183.324... TONS) ELECTRICAL INSTALLATION Power Sources and Distribution Systems § 183.324 Dual voltage generators. (a) A dual voltage generator installed on a vessel shall be of the grounded type, where: (1) The...

  5. 46 CFR 183.324 - Dual voltage generators.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Dual voltage generators. 183.324 Section 183.324... TONS) ELECTRICAL INSTALLATION Power Sources and Distribution Systems § 183.324 Dual voltage generators. (a) A dual voltage generator installed on a vessel shall be of the grounded type, where: (1) The...

  6. 46 CFR 183.324 - Dual voltage generators.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Dual voltage generators. 183.324 Section 183.324... TONS) ELECTRICAL INSTALLATION Power Sources and Distribution Systems § 183.324 Dual voltage generators. (a) A dual voltage generator installed on a vessel shall be of the grounded type, where: (1) The...

  7. Fringe Formation in Dual-Hologram Interferometry

    NASA Technical Reports Server (NTRS)

    Burner, A. W.

    1989-01-01

    A first order geometrical optics treatment of holograms combined with the generation of interference fringes by two point sources is used to describe reference fringe formation in non-diffuse dual-hologram interferometry.

  8. 3D non-contrast-enhanced ECG-gated MR angiography of the lower extremities with dual-source radiofrequency transmission at 3.0 T: Intraindividual comparison with contrast-enhanced MR angiography in PAOD patients.

    PubMed

    Rasper, Michael; Wildgruber, Moritz; Settles, Marcus; Eckstein, Hans-Henning; Zimmermann, Alexander; Reeps, Christian; Rummeny, Ernst J; Huber, Armin M

    2016-09-01

    To compare prospectively image quality and diagnostic confidence of flow-sensitive 3D turbo spin echo (TSE)-based non-contrast-enhanced MR angiography (NE-MRA) at 3.0 T using dual-source radiofrequency (RF) transmission with contrast-enhanced MRA (CE-MRA) in patients with peripheral arterial occlusive disease (PAOD). After consent was obtained, 35 patients (mean age 69.1 ± 10.6 years) with PAOD stage II-IV underwent NE-MRA followed by CE-MRA. Signal-to-noise ratio and contrast-to-noise ratio were calculated. Subjective image quality was independently assessed by two radiologists and stenosis scoring was performed in 875 arterial segments. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for stenosis classification were calculated using CE-MRA as a reference method. Diagnostic agreement with CE-MRA was evaluated with Cohen's kappa statistics. NE-MRA provided high objective and subjective image quality at all levels of the arterial tree. Sensitivity and specificity for the detection of relevant stenosis was 91 % and 89 %, respectively; the NPV was 96 % and the PPV 78 %. There was good concordance between CE-MRA and NE-MRA in stenosis scoring. 3D electrocardiography (ECG)-gated TSE NE-MRA with patient-adaptive dual-source RF transmission at 3.0 T is a promising alternative for PAOD patients with contraindications for gadolinium-based contrast agents. It offers high sensitivity and NPV values in the detection of clinically relevant arterial stenosis. • Flow-sensitive TSE NE-MRA is a promising technique for PAOD evaluation. • Diagnostic accuracy is comparable to contrast-enhanced MRA. • NE-MRA eliminates the risk of NSF in patients with renal insufficiency. • Costs arising from the use of contrast agents can be avoided.

  9. Detection of ischaemic myocardial lesions with coronary CT angiography and adenosine-stress dynamic perfusion imaging using a 128-slice dual-source CT: diagnostic performance in comparison with cardiac MRI

    PubMed Central

    Kim, S M; Choi, J-H; Chang, S-A

    2013-01-01

    Objective: We assessed the diagnostic performance of adenosine-stress dynamic CT perfusion (ASDCTP) imaging and coronary CT angiography (CCTA) for the detection of ischaemic myocardial lesions using 128-slice dual-source CT compared with that of 1.5 T cardiac MRI. Methods: This prospective study included 33 patients (61±8 years, 82% male) with suspected coronary artery diseases who underwent ASDCTP imaging and adenosine-stress cardiac MRI. Two investigators independently evaluated ASDCTP images in correlation with significant coronary stenosis on CCTA using two different thresholds of 50% and 70% diameter stenosis. Hypoattenuated myocardial lesions on ASDCTP associated with significant coronary stenoses on CCTA were regarded as true perfusion defects. All estimates of diagnostic performance were calculated and compared with those of cardiac MRI. Results: With use of a threshold of 50% diameter stenosis on CCTA, the diagnostic estimates per-myocardial segment were as follows: sensitivity, 81% [95% confidence interval (CI): 70–92%]; specificity, 94% (95% CI: 92–96%); and accuracy 93% (95% CI: 91–95%). With use of a threshold of 70%, the diagnostic estimates were as follows: sensitivity, 48% (95% CI: 34–62%); specificity, 99% (95% CI: 98–100%); and accuracy, 94% (95% CI: 92–96%). Conclusion: Dynamic CTP using 128-slice dual-source CT enables the assessment of the physiological significance of coronary artery lesions with high diagnostic accuracy in patients with clinically suspected coronary artery disease. Advances in knowledge: Combined CCTA and ASDCTP yielded high accuracy in the detection of perfusion defects regardless of the threshold of significant coronary stenosis. PMID:24096592

  10. Effect of the working gas of the ion-assisted source on the optical and mechanical properties of SiO2 films deposited by dual ion beam sputtering with Si and SiO2 as the starting materials.

    PubMed

    Wu, Jean-Yee; Lee, Cheng-Chung

    2006-05-20

    Silicon and fused-silica targets are used as the starting materials for depositing silicon oxide (SiO2) films. The SiO2 films are prepared by a dual ion beam sputtering deposition system with a main ion source and an ion-assisted source with different working gases. The films deposited are then examined and compared by using a visible spectrophotometer, a Fourier-transform IR spectrophotometer, an atomic force microscope, and contact angle instruments. A Twyman-Green interferometer is employed to study the film stress by phase-shift interferometry. All the SiO2 films show excellent optical properties with extra-low extinction coefficients (below 2x10(-5)) and have no water absorption. When the working gas is O2 for the ion-assisted source, the deposited SiO2 films show good properties in terms of stress and roughness and with a good molecular bonding structure order for both targets. However, SiO2 films deposited from the fused-silica target had a larger contact angle, while those deposited from the silicon target had 2.5 times the deposition rate.

  11. Quantitative and Qualitative Comparison of Single-Source Dual-Energy Computed Tomography and 120-kVp Computed Tomography for the Assessment of Pancreatic Ductal Adenocarcinoma.

    PubMed

    Bhosale, Priya; Le, Ott; Balachandran, Aprana; Fox, Patricia; Paulson, Eric; Tamm, Eric

    2015-01-01

    The aim of this study was to compare contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) between pancreatic-phase dual-energy computed tomography (DECT) and 120-kVp CT for pancreatic ductal adenocarcinoma (PDA). Seventy-eight patients underwent multiphasic pancreatic imaging protocols for PDA (40, DECT; 38, 120-kVp CT [control]). Using pancreatic phase, CNR and SNR for PDA were obtained for DECT at monochromatic energies 50 through 80 keV, iodine material density images, and 120-kVp images. Using a 5-point scale (1, excellent; 5, markedly limited), images were qualitatively assessed by 2 radiologists in consensus for PDA detection, extension, vascular involvement, and noise. Wilcoxon signed rank and 2-sample tests were used to compare the qualitative measures, CNR and SNR, for DECT and 120-kVp images. Bonferroni correction was applied. Iodine material density image had significantly higher CNR and SNR for PDA than any monochromatic energy images (P < 0.0001) and the 120-kVp images. Qualitatively, 70-keV images were rated highest in the categories of tumor extension and vascular invasion and were similar to 120-kVp images. Our results indicate that DECT improves PDA lesion conspicuity compared with routine 120-kVp CT, which may allow for better detection of PDA.

  12. SU-E-J-71: Feasibility Study On MRI-Based BANG3 Gel Dosimetry Using Dual-Source Parallel RF Transmission System

    SciTech Connect

    Kim, S; Lee, J; Lee, D; Lee, S; Choe, B; Baek, H

    2014-06-01

    Purpose: In this work, we present the feasibility of use of the parallel RF transmission with multiple RF source (MultiTransmit) imaging in MRI-based polymer gel dosimetry. Methods: The commercially available BANG3 gel was used for gel dosimetry. Spin-spin relaxation rate R2 was used to quantify the absorbed dose. The image quality (signal-to-noise ratio, SNR; image uniformity) and B1 field inhomogeneity between conventional single-source and MultiTransmit MR imaging were compared. Finally, the estimated R2 uncertainty σ(R2) and dosimetric performance (i.e., dose resolution) between conventional single-source and MultiTransmit MR imaging were compared. Results: Image quality and B1 field homogeneity within each calibration vial and large phantom was statistically better in MultiTransmit imaging than in conventional single-source RF transmission imaging (P < 0.005 for all calibration vials). In particular, σ(R2) (defined as the standard uncertainty of R2) was lower on the MultiTransmit images than on the conventional single-source images. Furthermore, the MultiTransmit measurement gives a lower than that obtained using the conventional single-source method. Conclusion: The improved image quality and B1 homogeneity resulted in reduced dose uncertainty (i.e., σ(R2) and dose resolution) in MRI-based polymer gel dosimetry, suggesting that MultiTransmit MR imaging has potential benefits for use in clinical 3D gel dosimetry without the need for the complicated B1 field correction method.

  13. Differentiation among Multiple Sources of Anthropogenic Nitrate in a Complex Groundwater System using Dual Isotope Systematics: A case study from Mortandad Canyon, New Mexico

    NASA Astrophysics Data System (ADS)

    Larson, T. E.; Perkins, G.; Longmire, P.; Heikoop, J. M.; Fessenden, J. E.; Rearick, M.; Fabyrka-Martin, J.; Chrystal, A. E.; Dale, M.; Simmons, A. M.

    2009-12-01

    The groundwater system beneath Los Alamos National Laboratory has been affected by multiple sources of anthropogenic nitrate contamination. Average NO3-N concentrations of up to 18.2±1.7 mg/L have been found in wells in the perched intermediate aquifer beneath one of the more affected sites within Mortandad Canyon. Sources of nitrate potentially reaching the alluvial and intermediate aquifers include: (1) sewage effluent, (2) neutralized nitric acid, (3) neutralized 15N-depleted nitric acid (treated waste from an experiment enriching nitric acid in 15N), and (4) natural background nitrate. Each of these sources is unique in δ18O and δ15N space. Using nitrate stable isotope ratios, a mixing model for the three anthropogenic sources of nitrate was established, after applying a linear subtraction of the background component. The spatial and temporal variability in nitrate contaminant sources through Mortandad Canyon is clearly shown in ternary plots. While microbial denitrification has been shown to change groundwater nitrate stable isotope ratios in other settings, the redox potential, relatively high dissolved oxygen content, increasing nitrate concentrations over time, and lack of observed NO2 in these wells suggest minimal changes to the stable isotope ratios have occurred. Temporal trends indicate that the earliest form of anthropogenic nitrate in this watershed was neutralized nitric acid. Alluvial wells preserve a trend of decreasing nitrate concentrations and mixing models show decreasing contributions of 15N-depleted nitric acid. Nearby intermediate wells show increasing nitrate concentrations and mixing models indicate a larger component derived from 15N-depleted nitric acid. These data indicate that the pulse of neutralized 15N-depleted nitric acid that was released into Mortandad Canyon between 1986 and 1989 has infiltrated through the alluvial aquifer and is currently affecting two intermediate wells. This hypothesis is consistent with previous

  14. Recent Progress on Compact and Portable Terahertz Source Based on Parametric Conversion from Dual-Frequency Solid-State Laser Pulses

    NASA Astrophysics Data System (ADS)

    Ding, Yujie J.; Zhao, Pu; Li, Da

    2013-02-01

    We review the progress made on power scaling and compact and portable THz sources. By reversely stacking GaP plates, we improved photon conversion efficiency from 25% to 40%, which is the maximum value. As the number of the plates was increased from 4 to 5, the output power was decreased due to back conversion. We also investigated THz generation by mixing two frequencies generated by a single Nd:YLF solid-state laser. The average output power reached 1 μW. By introducing two Nd:YLF crystals, we significantly improved the output power to 4.5 μW. Such a configuration allowed us to generate different output frequencies. We have also reviewed our effort of making the THz source further compact by exploiting passively Q-switched laser pulses.

  15. Using dual isotopes to identify sources and transformations of nitrogen in water catchments with different land uses, Loess Plateau of China.

    PubMed

    Xing, Meng; Liu, Weiguo

    2016-01-01

    Nitrogen pollution in rivers is a research hotspot in the field of biogeochemistry. However, the types and sources of pollution have historically been poorly understood in the water catchments of the Loess Plateau in China. In this study, we have chosen the main waterway and four lesser branches of the Jinghe River that vary by land use. We investigated the concentrations and isotopic signatures of nitrogen in river water. Our results revealed that nitrate was the dominant nitrogen type in river catchments of the Loess Plateau. The δ(15)N and δ(18)O values showed that NO3 (-) ions in the studied river samples were derived from precipitation, manure, sewage, soil organic nitrogen, and synthetic NO3 (-) fertilizer. The δ(18)O-NO3 (-) values during July 2012 (mean ± SD = +18.1 ± 1.5‰) were higher than those during the September 2013 (mean ± SD = +7.8 ± 3.7‰), which indicated that mixing with atmospheric NO3 (-) resulted in the high δ(18)O values during July 2012. It appears that no intense nitrification and denitrification occurred in all five rivers according to the isotopic and chemical data. A Bayesian model was used to determine the contributions of four NO3 (-) sources to all five rivers. Results showed that source contributions differ significantly between July and September, and the four potential NO3 (-) sources also showed high variability between the different land use areas.

  16. Amino acids as a nitrogen source in temperate upland grasslands: the use of dual labelled ((13)C, (15)N) glycine to test for direct uptake by dominant grasses.

    PubMed

    Streeter, T C; Bol, R; Bardgett, R D

    2000-01-01

    It is becoming increasingly apparent that soil amino acids are a principal source of nitrogen (N) for certain plants, and especially those of N-limited environments. This study of temperate upland grasslands used glycine-2-(13)C-(15)N and ((15)NH4)(2)SO(4) labelling techniques to test the hypothesis that plant species which dominate 'unimproved' semi-natural grasslands (Festuca-Agrostis-Galium) are able to utilise amino acid N for growth, whereas those plants which dominate 'improved' grasslands (Lolium-Cynosurus), that receive regular applications of inorganic fertiliser, use inorganic N forms as their main N source. Data from field experiments confirmed that 'free' amino acids were more abundant in 'unimproved' than 'improved' grassland and that glycine was the dominant amino acid type (up to 42% of total). Secondly, the injection of representative amounts of glycine-2-(13)C-(15)N (4.76 and 42.86 mM) into intact soil cores from the two grassland types provided evidence of direct uptake of glycine by plants, with both (15)N and (13)C being detected in plant material of both grasslands. Finally, a microcosm experiment demonstrated no preferential uptake of amino acid N by the grasses which dominate the grassland types, namely Holcus lanatus, Festuca rubra, Agrostis capillaris from the 'unimproved' grassland, and Lolium perenne from the 'improved' grassland. Again, both (13)C and (15)N were detected in all grass species suggesting uptake of intact glycine by these plants.

  17. Efficient anaerobic production of succinate from glycerol in engineered Escherichia coli by using dual carbon sources and limiting oxygen supply in preceding aerobic culture.

    PubMed

    Li, Qing; Huang, Bing; Wu, Hui; Li, Zhimin; Ye, Qin

    2017-05-01

    Glycerol is an important resource for production of value-added bioproducts due to its large availability from the biodiesel industry as a by-product. In this study, two metabolic regulation strategies were applied in the aerobic stage of a two-stage fermentation to achieve high metabolic capacities of the pflB ldhA double mutant Escherichia coli strain overexpressing phosphoenolpyruvate carboxykinase (PCK) in the subsequent anaerobic stage: use of acetate as a co-carbon source of glycerol and restriction of oxygen supply in the PCK induction period. The succinate concentration achieved 926.7mM with a yield of 0.91mol/mol during the anaerobic stage of fermentation in a 1.5-L reactor. qRT-PCR indicated that the two strategies enhanced transcription of genes related with glycerol metabolism and succinate production. Our results showed this metabolically engineered E. coli strain has a great potential in producing succinate using glycerol as carbon source. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Very low-dose (0.15 mGy) chest CT protocols using the COPDGene 2 test object and a third-generation dual-source CT scanner with corresponding third-generation iterative reconstruction software.

    PubMed

    Newell, John D; Fuld, Matthew K; Allmendinger, Thomas; Sieren, Jered P; Chan, Kung-Sik; Guo, Junfeng; Hoffman, Eric A

    2015-01-01

    The purpose of this study was to evaluate the impact of ultralow radiation dose single-energy computed tomographic (CT) acquisitions with Sn prefiltration and third-generation iterative reconstruction on density-based quantitative measures of growing interest in phenotyping pulmonary disease. The effects of both decreasing dose and different body habitus on the accuracy of the mean CT attenuation measurements and the level of image noise (SD) were evaluated using the COPDGene 2 test object, containing 8 different materials of interest ranging from air to acrylic and including various density foams. A third-generation dual-source multidetector CT scanner (Siemens SOMATOM FORCE; Siemens Healthcare AG, Erlangen, Germany) running advanced modeled iterative reconstruction (ADMIRE) software (Siemens Healthcare AG) was used.We used normal and very large body habitus rings at dose levels varying from 1.5 to 0.15 mGy using a spectral-shaped (0.6-mm Sn) tube output of 100 kV(p). Three CT scans were obtained at each dose level using both rings. Regions of interest for each material in the test object scans were automatically extracted. The Hounsfield unit values of each material using weighted filtered back projection (WFBP) at 1.5 mGy was used as the reference value to evaluate shifts in CT attenuation at lower dose levels using either WFBP or ADMIRE. Statistical analysis included basic statistics, Welch t tests, multivariable covariant model using the F test to assess the significance of the explanatory (independent) variables on the response (dependent) variable, and CT mean attenuation, in the multivariable covariant model including reconstruction method. Multivariable regression analysis of the mean CT attenuation values showed a significant difference with decreasing dose between ADMIRE and WFBP. The ADMIRE has reduced noise and more stable CT attenuation compared with WFBP. There was a strong effect on the mean CT attenuation values of the scanned materials for ring

  19. Prospectively ECG-triggered high-pitch coronary angiography with third-generation dual-source CT at 70 kVp tube voltage: feasibility, image quality, radiation dose, and effect of iterative reconstruction.

    PubMed

    Hell, Michaela M; Bittner, Daniel; Schuhbaeck, Annika; Muschiol, Gerd; Brand, Michael; Lell, Michael; Uder, Michael; Achenbach, Stephan; Marwan, Mohamed

    2014-01-01

    Low tube voltage reduces radiation exposure in coronary CT angiography (CTA). Using 70 kVp tube potential has so far not been possible because CT systems were unable to provide sufficiently high tube current with low voltage. We evaluated feasibility, image quality (IQ), and radiation dose of coronary CTA using a third-generation dual-source CT system capable of producing 450 mAs tube current at 70 kVp tube voltage. Coronary CTA was performed in 26 consecutive patients with suspected coronary artery disease, selected for body weight <100 kg and heart rate <60 beats/min. High-pitch spiral acquisition was used. Filtered back projection (FBP) and iterative reconstruction (IR) algorithms were applied. IQ was assessed using a 4-point rating scale (1 = excellent, 4 = nondiagnostic) and objective parameters. Mean age was 62 ± 9 years (46% males; mean body mass index, 27.7 ± 3.8 kg/m(2); mean heart rate, 54 ± 5 beats/min). Mean dose-length product was 20.6 ± 1.9 mGy × cm; mean estimated effective radiation dose was 0.3 ± 0.03 mSv. Diagnostic IQ was found in 365 of 367 (FBP) and 366 of 367 (IR) segments (P nonsignificant). IQ was rated "excellent" in 53% (FBP) and 86% (IR) segments (P = .001) and "nondiagnostic" in 2 (FBP) and 1 segment (IR) (P nonsignificant). Mean IQ score was lesser in FBP vs IR (1.5 ± 0.4 vs 1.1 ± 0.2; P < .001). Image noise was lower in IR vs FBP (60 ± 10 HU vs 74 ± 8 HU; P < .001). In patients <100 kg and with a regular heart rate <60 beats/min, third-generation dual-source CT using high-pitch spiral acquisition and 70 kVp tube voltage is feasible and provides both robust IQ and very low radiation exposure. Copyright © 2014 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  20. Identification of groundwater contamination sources of nitrate and sulfate in shallow alluvial aquifers using a dual-isotope approach in an agricultural area

    NASA Astrophysics Data System (ADS)

    Kaown, D.; Koh, D.; Mayer, B.; Hyun, Y.; Bae, G.; Lee, K.

    2007-12-01

    The elevated level of nitrate in groundwater is a serious problem in Korean agricultural areas. Yupori, a small agricultural area in Chuncheon (Korea), shows a rising level of NO3-N and displays multiple NO3-N sources from non-point and point sources in shallow aquifer groundwater. Numerous vegetable fields are located in the western part of the study area and fruit orchards dominate the landscape with only few vegetable fields in the eastern part of the study area. The source identification of groundwater contamination from overburden agricultural area was undertaken by analyzing hydrochemical data and stable isotopic compositions of dissolved nitrate and sulfate (¥ä15N-NO3-, ¥ä18O-NO3-, ¥ä34S-SO42-, and ¥ä18O-SO42-). The measurements of ¥ä15N- NO3- are in the range of 7.1 to 14.4¢¶ and the values of ¥ä18O-NO3- are in the range of -1.8 to 6.5¢¶. High ¥ä15N-NO3- values shown at low concentrations of nitrate in the eastern Yupori are characteristics of manure- derived nitrate and organic soil. The values of ¥ä34S-SO4-2 ranged from 2.9 to 9.9¢¶ and ¥ä18O-SO42- ranged from 2.5 to 4.7¢¶. At high concentrations of SO42- in the western Yupori, the value of ¥ä34S-SO42- are low around 3-4¢¶. The value of ¥ä34S-SO42- increased with decreasing SO42- concentration in the eastern Yupori. Groundwater quality and stable isotopic compositions of dissolved nitrate and sulfate seem to be significantly affected by agricultural land use pattern of the study site.

  1. Dual surface interferometer

    DOEpatents

    Pardue, R.M.; Williams, R.R.

    1980-09-12

    A double-pass interferometer is provided which allows direct measurement of relative displacement between opposed surfaces. A conventional plane mirror interferometer may be modified by replacing the beam-measuring path cube-corner reflector with an additional quarterwave plate. The beam path is altered to extend to an opposed plane mirrored surface and the reflected beam is placed in interference with a retained reference beam split from dual-beam source and retroreflected by a reference cube-corner reflector mounted stationary with the interferometer housing. This permits direct measurement of opposed mirror surfaces by laser interferometry while doubling the resolution as with a conventional double-pass plane mirror laser interferometer system.

  2. Dual surface interferometer

    DOEpatents

    Pardue, Robert M.; Williams, Richard R.

    1982-01-01

    A double-pass interferometer is provided which allows direct measurement of relative displacement between opposed surfaces. A conventional plane mirror interferometer may be modified by replacing the beam-measuring path cube-corner reflector with an additional quarter-wave plate. The beam path is altered to extend to an opposed plane mirrored surface and the reflected beam is placed in interference with a retained reference beam split from dual-beam source and retroreflected by a reference cube-corner reflector mounted stationary with the interferometer housing. This permits direct measurement of opposed mirror surfaces by laser interferometry while doubling the resolution as with a conventional double-pass plane mirror laser interferometer system.

  3. Fringe formation in dual-hologram interferometry

    NASA Astrophysics Data System (ADS)

    Burner, A. W.

    Reference-fringe formation in nondiffuse dual-hologram interferometry is described by combining a first-order geometrical hologram treatment with interference fringes generated by two point sources. The first-order imaging relationships can be used to describe reference-fringe patterns for the geometry of the dual-hologram interferometry. The process can be completed without adjusting the two holograms when the reconstructing wavelength is less than the exposing wavelength, and the process is found to facilitate basic intereferometer adjustments.

  4. Dual sources of water overprinting on the low zircon δ18O metamorphic country rocks: Disequilibrium constrained through inverse modelling of partial reequilibration

    NASA Astrophysics Data System (ADS)

    Wei, Chun-Sheng; Zhao, Zi-Fu

    2017-01-01

    Since water is only composed of oxygen and hydrogen, δ18O and δ2H values are thus utilized to trace the origin of water(s) and quantify the water-rock interactions. While Triassic high pressure (HP) and ultrahigh pressure (UHP) metamorphic rocks across the Dabie-Sulu orogen in central-eastern China have been well documented, postcollisional magmatism driven hydrothermal systems are little known. Here we show that two sources of externally derived water interactions were revealed by oxygen isotopes for the gneissic country rocks intruded by the early Cretaceous postcollisional granitoids. Inverse modellings indicate that the degree of disequilibrium (doD) of meteoric water interactions was more evident than that of magmatic one (-65 ± 1o vs. -20 ± 2°) the partial reequilibration between quartz and alkali feldspar oxygen isotopes with magmatic water was achieved at 340 °C with a water/rock (W/R) ratio of about 1.2 for an open-hydrothermal system; two-stage meteoric water interactions were unraveled with reequilibration temperatures less than 300 °C and W/R ratios around 0.4. The lifetime of fossil magmatic hydrothermal system overprinted on the low zircon δ18O orthogneissic country rocks was estimated to maintain up to 50 thousand years (Kyr) through oxygen exchange modellings. Four-stage isotopic evolutions were proposed for the magmatic water interacted gneiss.

  5. Dual sources of water overprinting on the low zircon δ18O metamorphic country rocks: Disequilibrium constrained through inverse modelling of partial reequilibration

    PubMed Central

    Wei, Chun-Sheng; Zhao, Zi-Fu

    2017-01-01

    Since water is only composed of oxygen and hydrogen, δ18O and δ2H values are thus utilized to trace the origin of water(s) and quantify the water-rock interactions. While Triassic high pressure (HP) and ultrahigh pressure (UHP) metamorphic rocks across the Dabie-Sulu orogen in central-eastern China have been well documented, postcollisional magmatism driven hydrothermal systems are little known. Here we show that two sources of externally derived water interactions were revealed by oxygen isotopes for the gneissic country rocks intruded by the early Cretaceous postcollisional granitoids. Inverse modellings indicate that the degree of disequilibrium (doD) of meteoric water interactions was more evident than that of magmatic one (−65 ± 1o vs. −20 ± 2°); the partial reequilibration between quartz and alkali feldspar oxygen isotopes with magmatic water was achieved at 340 °C with a water/rock (W/R) ratio of about 1.2 for an open-hydrothermal system; two-stage meteoric water interactions were unraveled with reequilibration temperatures less than 300 °C and W/R ratios around 0.4. The lifetime of fossil magmatic hydrothermal system overprinted on the low zircon δ18O orthogneissic country rocks was estimated to maintain up to 50 thousand years (Kyr) through oxygen exchange modellings. Four-stage isotopic evolutions were proposed for the magmatic water interacted gneiss. PMID:28091552

  6. Dual sources of water overprinting on the low zircon δ(18)O metamorphic country rocks: Disequilibrium constrained through inverse modelling of partial reequilibration.

    PubMed

    Wei, Chun-Sheng; Zhao, Zi-Fu

    2017-01-16

    Since water is only composed of oxygen and hydrogen, δ(18)O and δ(2)H values are thus utilized to trace the origin of water(s) and quantify the water-rock interactions. While Triassic high pressure (HP) and ultrahigh pressure (UHP) metamorphic rocks across the Dabie-Sulu orogen in central-eastern China have been well documented, postcollisional magmatism driven hydrothermal systems are little known. Here we show that two sources of externally derived water interactions were revealed by oxygen isotopes for the gneissic country rocks intruded by the early Cretaceous postcollisional granitoids. Inverse modellings indicate that the degree of disequilibrium (doD) of meteoric water interactions was more evident than that of magmatic one (-65 ± 1(o) vs. -20 ± 2°); the partial reequilibration between quartz and alkali feldspar oxygen isotopes with magmatic water was achieved at 340 °C with a water/rock (W/R) ratio of about 1.2 for an open-hydrothermal system; two-stage meteoric water interactions were unraveled with reequilibration temperatures less than 300 °C and W/R ratios around 0.4. The lifetime of fossil magmatic hydrothermal system overprinted on the low zircon δ(18)O orthogneissic country rocks was estimated to maintain up to 50 thousand years (Kyr) through oxygen exchange modellings. Four-stage isotopic evolutions were proposed for the magmatic water interacted gneiss.

  7. Effect of nitrogen flow rate on structural, morphological and optical properties of In-rich InxAl1-xN thin films grown by plasma-assisted dual source reactive evaporation

    NASA Astrophysics Data System (ADS)

    Alizadeh, M.; Ganesh, V.; Goh, B. T.; Dee, C. F.; Mohmad, A. R.; Rahman, S. A.

    2016-08-01

    In-rich InxAl1-xN thin films were deposited on quartz substrate at various nitrogen flow rates by plasma-assisted dual source reactive evaporation technique. The elemental composition, surface morphology, structural and optical properties of the films were investigated by X-ray photoelectron spectroscopy (XPS), field emission scanning electron microscopy (FESEM), Raman spectroscopy, X-ray diffraction (XRD), UV-vis spectrophotometer and photoluminescence (PL) measurements. XPS results revealed that the indium composition (x) of the InxAl1-xN films increases from 0.90 to 0.97 as the nitrogen flow rate is increased from 40 to 100 sccm, respectively. FESEM images of the surface and cross-sectional microstructure of the InxAl1-xN films showed that by increasing the N2 flow rate, the grown particles are highly agglomerated. Raman and XRD results indicated that by increasing nitrogen flow rate the In-rich InxAl1-xN films tend to turn into amorphous state. It was found that band gap energy of the films are in the range of 0.90-1.17 eV which is desirable for the application of full spectra solar cells.

  8. Dual 10Be isotope systems constrain the source of sediment and rate of erosion for the tropical Barron River catchment, Queensland, Australia

    NASA Astrophysics Data System (ADS)

    Nichols, K. K.; Bierman, P. R.; Reusser, L. J.; Portenga, E.; Matmon, A.; Rood, D. H.

    2010-12-01

    In order to understand source of sediment and rate of erosion for Barron River catchment, which heads on the Atherton Tablelands of northeast Australia, crosses the northern Queensland escarpment and drains into the Coral Sea, we collected fluvial sediment and measured both in situ and meteoric 10Be contents on the medium sand fraction. We collected fourteen samples from rivers and streams including large regional drainages and small tributaries. The upland basins are characterized by lower relief and less precipitation than the steeper and wetter escarpment basins. One sample is quartz sand from the Coral Sea beach at Yorkey's Knob, below the escarpment. Sand from the Barron River upstream of the escarpment integrates the upland basins and has an in situ 10Be concentration of 2.31±0.84 x105atoms/g and an erosion rate of 17.2 m/My (calculated using the CRONOS on-line calculator). This is similar to a major upland tributary (2.51±0.40 x105 atoms/g; 15.2 m/My) and two smaller upstream tributaries (20.5 m/My and 21.4 m/My). Escarpment streams have less in situ 10Be in their sediment (mean = 1.64±0.55 x 105 atoms/g, n=8) and higher basin area-weighted erosion rates (37.2 m/My). Based on the in situ measurements, the uplands are eroding at approximately half the rate of the escarpment basins. The beach sand has an in situ 10Be concentration (2.75±0.19 x 105 atoms/g) similar to the upland sediment suggesting that the source of beach sand is the larger but more slowly eroding Tablelands. In contrast, the meteoric 10Be concentrations of Barron River sand-sized sediment collected above the escarpment is ~4 fold lower (2.55x107 atoms/g) than the average meteoric 10Be concentration of the 8 escarpment samples (9.94±4.49 x107 atoms/g). This discrepancy cannot be explained by differences in annual average precipitation which ranges only from 1.9 to 2.3 m/yr but likely results from the deep mobility of meteoric 10Be in oxic Tableland soils. Considering meteoric 10Be as a

  9. Dose reduction in spiral CT coronary angiography with dual source equipment. Part II. Dose surplus due to slope-up and slope-down of prospective tube current modulation in a phantom model.

    PubMed

    Martini, C; Palumbo, A; Maffei, E; Rossi, A; Rengo, M; Malagò, R; Dijkshoorn, M; Weustink, A; Mollet, N; Krestin, G; Cademartiri, F

    2010-02-01

    This study was undertaken to estimate surplus radiation dose in retrospectively electrocardiography (ECG)-gated dual-source computed tomography coronary angiography (DSCT-CA) due to the slope-up and slope-down of the tube current using prospectively ECG-triggered tube modulation. We used an anthropomorphic phantom with an ECG-gated retrospective protocol and a DSCT scanner (Definition, Siemens). We used four tube current modulation algorithms: narrow pulsing window, with tube current reduction to 20% (A) and 4% (B) of peak current; and wide pulsing window, with tube current reduction to 20% (C) and 4% (D). Each algorithm was applied at five heart rates (HR=45, 60, 75, 90 and 120 bpm) with adaptive pitch values (0.2-0.5). Data sets were reconstructed in 5% increments from 0-95% of the R-R interval. Noise was measured at each R-R step in order to identify low noise (100% dose), medium noise (slope-up/down) and high noise (4/20% dose). Width of the transition window (slope-up/slope-down from 4/20% to 100% dose) was calculated. The surplus dose due to slope-up/slope-down was calculated. Surplus dose was 19% (A), 34% (B), 14% (C) and 21% (D). The transition window lasted 10%+10% (slope-up + down) for HR <75 bpm and all HR in C (except for 120 bpm; 25%+15%), 15%+15% for HR >90 bpm (A). For C and D, instead, the slope-up increased with progressively higher HR (10%-25% of the R-R interval, except for 90 bpm, 10%), whereas the slope-down remained constant at 5% (except for 120 bpm; 10%). The adaptive ECG-pulsing windows produced an increment of the surplus dose with increasing HR. The transition window was a constant source of surplus radiation dose in the range of 14%-34%.

  10. Dual Wavelength Lasers

    NASA Technical Reports Server (NTRS)

    Walsh, Brian M.

    2010-01-01

    Dual wavelength lasers are discussed, covering fundamental aspects on the spectroscopy and laser dynamics of these systems. Results on Tm:Ho:Er:YAG dual wavelength laser action (Ho at 2.1 m and Er at 2.9 m) as well as Nd:YAG (1.06 and 1.3 m) are presented as examples of such dual wavelength systems. Dual wavelength lasers are not common, but there are criteria that govern their behavior. Based on experimental studies demonstrating simultaneous dual wavelength lasing, some general conclusions regarding the successful operation of multi-wavelength lasers can be made.

  11. Effect of automated tube voltage selection, integrated circuit detector and advanced iterative reconstruction on radiation dose and image quality of 3rd generation dual-source aortic CT angiography: An intra-individual comparison.

    PubMed

    Mangold, Stefanie; De Cecco, Carlo N; Wichmann, Julian L; Canstein, Christian; Varga-Szemes, Akos; Caruso, Damiano; Fuller, Stephen R; Bamberg, Fabian; Nikolaou, Konstantin; Schoepf, U Joseph

    2016-05-01

    To compare, on an intra-individual basis, the effect of automated tube voltage selection (ATVS), integrated circuit detector and advanced iterative reconstruction on radiation dose and image quality of aortic CTA studies using 2nd and 3rd generation dual-source CT (DSCT). We retrospectively evaluated 32 patients who had undergone CTA of the entire aorta with both 2nd generation DSCT at 120kV using filtered back projection (FBP) (protocol 1) and 3rd generation DSCT using ATVS, an integrated circuit detector and advanced iterative reconstruction (protocol 2). Contrast-to-noise ratio (CNR) was calculated. Image quality was subjectively evaluated using a five-point scale. Radiation dose parameters were recorded. All studies were considered of diagnostic image quality. CNR was significantly higher with protocol 2 (15.0±5.2 vs 11.0±4.2; p<.0001). Subjective image quality analysis revealed no significant differences for evaluation of attenuation (p=0.08501) but image noise was rated significantly lower with protocol 2 (p=0.0005). Mean tube voltage and effective dose were 94.7±14.1kV and 6.7±3.9mSv with protocol 2; 120±0kV and 11.5±5.2mSv with protocol 1 (p<0.0001, respectively). Aortic CTA performed with 3rd generation DSCT, ATVS, integrated circuit detector, and advanced iterative reconstruction allow a substantial reduction of radiation exposure while improving image quality in comparison to 120kV imaging with FBP. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  12. Adenosine-stress dynamic myocardial perfusion imaging using 128-slice dual-source CT in patients with normal body mass indices: effect of tube voltage, tube current, and iodine concentration on image quality and radiation dose.

    PubMed

    Kim, Sung Mok; Cho, Young Kwon; Choe, Yeon Hyeon

    2014-12-01

    The aim of this study was to evaluate the image quality and radiation dose in adenosine-stress dynamic myocardial CT perfusion (CTP) imaging using different tube voltages, tube current settings, and contrast materials containing different iodine concentrations in subjects with normal body mass indices (BMI). We included 92 patients (BMI range, 18.5-24.8) who underwent dynamic CTP for the evaluation of coronary artery disease using a 128-slice dual-source computed tomography. The protocols employed the following dynamic scan parameters: protocol I with 100 kV, fixed tube current (FTC), and medium-concentration contrast material (MC, 350 mg iodine/mL); protocol II with 100 kV, automatic tube current modulation (ATCM), and MC; protocol III with 100 kV, ATCM, and high-concentration contrast material (HC, 400 mg iodine/mL); protocol IV with 80 kV, adopted FTC, and HC. Subjective image quality on a 1-3 point scale and objective image quality with respect to the contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) were assessed. Protocol IV showed higher CNR and SNR than the other protocols (P < 0.01), while the CNR and SNR values did not significantly differ among the other three protocols. There was no significant difference in subjective image quality among the protocols. The radiation dose in protocol IV was the lowest among the protocols (P < 0.01), while protocol IV resulted in a 54% overall reduction in mean effective radiation dose compared with protocol I. Dynamic myocardial CTP performed at 80 kV with adapted FTC provided high CNR and SNR while preserving subjective image quality and reducing radiation exposure.

  13. Comparison of image quality and radiation dose between prospectively ECG-triggered and retrospectively ECG-gated CT angiography: Establishing heart rate cut-off values in first-generation dual-source CT.

    PubMed

    Ünal, Emre; Yıldız, A Elçin; Güler, Ezgi; Karcaaltıncaba, Muşturay; Akata, Deniz; Kılınçer, Abidin; Atlı, Eray; Topçuoğlu, Melih; Hazırolan, Tuncay

    2015-09-01

    To evaluate radiation dose and image quality of prospectively electrocardiography (ECG)-triggered and retrospectively ECG-gated coronary computed tomography (CT) angiography and to establish cut-off values of heart rates (HRs) for each technique in first-generation dual-source CT. A total of 200 consecutive patients with suspected coronary artery disease were accepted into the study. Patients were selected randomly for each technique (prospective triggering group n=99, mean age 55.85±10.74 and retrospective gating group n=101, mean age 53.38±11.58). Two independent radiologists scored coronary artery segments for image quality using a 5-point scale. Also, attenuation values of each coronary artery segment and dose-length product values were measured. For each technique, cut-off HR values were determined for the best image quality. Mean image quality scores and attenuation values were found to be higher in the prospective triggering group (p<0.05). Mean radiation dose was 73% lower for the prospective triggering group (p<0.01). The cut-off HR values for good image quality scores were ≤67 beats per minute (bpm) and ≤80 bpm for the prospective triggering and retrospective gating groups, respectively (p<0.05). Increased HR (≥68 and ≥81 bpm, respectively) had negative effects on image quality (p<0.05). The prospective ECG triggering technique has better image quality scores than retrospective ECG gating, particularly in patients who have an HR of less than 68 bpm. Also, a 73% radiation dose reduction can be achieved with prospective ECG triggering. In patients with higher heart rates, retrospective ECG gating is recommended.

  14. TH-C-18A-12: Evaluation of the Impact of Body Size and Tube Output Limits in the Optimization of Fast Scanning with High-Pitch Dual Source CT

    SciTech Connect

    Ramirez Giraldo, J; Mileto, A.; Hurwitz, L.; Marin, D.

    2014-06-15

    Purpose: To evaluate the impact of body size and tube power limits in the optimization of fast scanning with high-pitch dual source CT (DSCT). Methods: A previously validated MERCURY phantom, made of polyethylene, with circular cross-section of diameters 16, 23, 30 and 37cm, and connected through tapered sections, was scanned using a second generation DSCT system. The DSCT operates with two independently controlled x-ray tube generators offering up to 200 kW power reserve (100 kW per tube). The entire length of the phantom (42cm) was scanned with two protocols using: A)Standard single-source CT (SSCT) protocol with pitch of 0.8, and B) DSCT protocol with high-pitch values ranging from 1.6 to 3.2 (0.2 steps). All scans used 120 kVp with 150 quality reference mAs using automatic exposure control. Scanner radiation output (CTDIvol) and effective mAs values were extracted retrospectively from DICOM files for each slice. Image noise was recorded. All variables were assessed relative to phantom diameter. Results: With standard-pitch SSCT, the scanner radiation output (and tube-current) were progressively adapted with increasing size, from 6 mGy (120 mAs) up to 15 mGy (270 mAs) from the thinnest (16cm) to the thickest diameter (37 cm), respectively. By comparison, using high-pitch (3.2), the scanner output was bounded at about 8 mGy (140 mAs), independent of phantom diameter. Although relative to standard-pitch, the high-pitch led to lower radiation output for the same scan, the image noise was higher, particularly for larger diameters. To match the radiation output adaptation of standard-pitch, a high-pitch mode of 1.6 was needed, with the advantage of scanning twice as fast. Conclusion: To maximize the benefits of fast scanning with high-pitch DSCT, the body size and tube power limits of the system need to be considered such that a good balance between speed of acquisition and image quality are warranted. JCRG is an employee of Siemens Medical Solutions USA Inc.

  15. Mental Health and Psychological Functioning of Dual-Career Families.

    ERIC Educational Resources Information Center

    Gilbert, Lucia Albino; Rachlin, Vicki

    1987-01-01

    Identifies key issues in the psychosocial development of women and men that are important to understanding dual-career marriages. Describes life as a dual career family considering rewards, sources of stress, and factors that promote effective coping. Addresses pertinent metaissues--concepts of equity and the nature of society. Offers…

  16. Dual-fuel, dual-throat engine preliminary analysis

    NASA Technical Reports Server (NTRS)

    Obrien, C. J.

    1979-01-01

    A propulsion system analysis of the dual fuel, dual throat engine for launch vehicle applications was conducted. Basic dual throat engine characterization data were obtained to allow vehicle optimization studies to be conducted. A preliminary baseline engine system was defined.

  17. Self-dual gravity

    NASA Astrophysics Data System (ADS)

    Krasnov, Kirill

    2017-05-01

    Self-dual gravity is a diffeomorphism invariant theory in four dimensions that describes two propagating polarisations of the graviton and has a negative mass dimension coupling constant. Nevertheless, this theory is not only renormalisable but quantum finite, as we explain. We also collect various facts about self-dual gravity that are scattered across the literature.

  18. Dual Enrollment Academy Programs

    ERIC Educational Resources Information Center

    Gonzalez, Nicolas; Chavez, Guadalupe

    2009-01-01

    Dual Enrollment Engineering (DEEA) and Medical Science (DEMSA) Academies are two-year dual enrollment programs for high school students. Students explore engineering and medical careers through college coursework. Students prepare for higher education in engineering and medical fields while completing associate degrees in biology or engineering…

  19. Dual Enrollment Academy Programs

    ERIC Educational Resources Information Center

    Gonzalez, Nicolas; Chavez, Guadalupe

    2009-01-01

    Dual Enrollment Engineering (DEEA) and Medical Science (DEMSA) Academies are two-year dual enrollment programs for high school students. Students explore engineering and medical careers through college coursework. Students prepare for higher education in engineering and medical fields while completing associate degrees in biology or engineering…

  20. Dual Credit Report

    ERIC Educational Resources Information Center

    Light, Noreen

    2016-01-01

    In 2015, legislation to improve access to dual-credit programs and to reduce disparities in access and completion--particularly for low income and underrepresented students--was enacted. The new law focused on expanding access to College in the High School but acknowledged issues in other dual-credit programs and reinforced the notion that cost…

  1. Dual-energy lung perfusion and ventilation CT in children.

    PubMed

    Goo, Hyun Woo

    2013-03-01

    Dual-energy thoracic CT provides two key insights into lung physiology, i.e. regional perfusion and ventilation, and has been actively investigated to find clinically relevant applications since the introduction of dual-source CT. This functional information provided by dual-energy thoracic CT is supplementary because high-resolution thoracic anatomy is entirely preserved on dual-energy thoracic CT. In addition, virtual non-contrast imaging can omit pre-contrast scanning. In this respect, dual-energy CT imaging technique is at least dose-neutral, which is a critical requirement for paediatric imaging. In this review, imaging protocols, analysis methods, clinical applications and diagnostic pitfalls of dual-energy thoracic CT for evaluating lung perfusion and ventilation in children are described.

  2. Treating the Dual-Career Couple.

    ERIC Educational Resources Information Center

    Goldenberg, Irene; Goldenberg, Herbert

    1984-01-01

    Discusses the dual-career couple in terms of common sources of family strains and gains resulting from career and domestic responsibilities. Presents case examples illustrating different forms of accomodation and possible subsequent problems. Strategies for stress reduction are presented and therapeutic guidelines offered. (JAC)

  3. Third-generation dual-source CT of the neck using automated tube voltage adaptation in combination with advanced modeled iterative reconstruction: evaluation of image quality and radiation dose.

    PubMed

    Scholtz, Jan-Erik; Wichmann, Julian L; Hüsers, Kristina; Albrecht, Moritz H; Beeres, Martin; Bauer, Ralf W; Vogl, Thomas J; Bodelle, Boris

    2016-08-01

    To evaluate image quality and radiation dose in third-generation dual-source computed tomography (DSCT) of the neck using automated tube voltage adaptation (TVA) with advanced modelled iterative reconstruction (ADMIRE) algorithm. One hundred and sixteen patients were retrospectively evaluated. Group A (n = 59) was examined on second-generation DSCT with automated TVA and filtered back projection. Group B (n = 57) was examined on a third-generation DSCT with automated TVA and ADMIRE. Age, body diameter, attenuation of several anatomic structures, noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), radiation dose (CTDIvol) and size-specific dose estimates (SSDE) were assessed. Diagnostic acceptability was rated by three readers. Age (p = 0.87) and body diameter (p = 0.075) did not differ significantly. Tube voltage in Group A was set automatically to 100 kV for all patients (n = 59), and to 70 kV (n = 2), 80 kV (n = 5), and 90 kV (n = 50) in Group B. Noise was reduced and CNR was increased significantly (p < 0.001). Diagnostic acceptability was rated high in both groups, with better ratings in Group B (p < 0.001). SSDE was reduced by 34 % in Group B (20.38 ± 1.63 mGy vs. 13.04 ± 1.50 mGy, p < 0.001). Combination of automated TVA and ADMIRE in neck CT using third-generation DSCT results in a substantial radiation dose reduction with low noise and increased CNR. • Third-generation DSCT provides automated tube voltage adaptation with an increment of 10 kV. • 10 kV increment optimizes scans to the patient's neck anatomy. • TVA combined with ADMIRE significantly lower radiation dose in contrast-enhanced neck CT. • TVA in combination with ADMIRE reduces noise and increases SNR and CNR. • Image analysis quoted less noise and better diagnostic acceptability in third-generation DSCT.

  4. A model for quantitative correction of coronary calcium scores on multidetector, dual source, and electron beam computed tomography for influences of linear motion, calcification density, and temporal resolution: a cardiac phantom study.

    PubMed

    Greuter, M J W; Groen, J M; Nicolai, L J; Dijkstra, H; Oudkerk, M

    2009-11-01

    The objective of this study is to quantify the influence of linear motion, calcification density, and temporal resolution on coronary calcium determination using multidetector computed tomography (MDCT), dual source CT (DSCT), and electron beam tomography (EBT) and to find a quantitative method which corrects for the influences of these parameters using a linear moving cardiac phantom. On a robotic arm with artificial arteries with four calcifications of increasing density, a linear movement was applied between 0 and 120 mm/s (step of 10 mm/s). The phantom was scanned five times on 64-slice MDCT, DSCT, and EBT using a standard acquisition protocol. The average Agatston, volume, and mass scores were determined for each velocity, calcification, and scanner. Susceptibility to motion was quantified using a cardiac motion susceptibility (CMS) index. Resemblance to EBT and physical volume and mass was quantified using a Delta index. Increasing motion artifacts were observed at increasing velocities on all scanners, with increasing severity from EBT to DSCT to 64-slice MDCT. The calcium score showed a linear dependency on motion from which a correction factor could be derived. This correction factor showed a linear dependency on the mean calcification density with a good fit for all three scoring methods and all three scanners (0.73 < or = R2 < or = 0.95). The slope and offset of this correction factor showed a linear dependency on temporal resolution with a good fit for all three scoring methods and all three scanners (0.83 < or = R2 < or = 0.98). CMS was minimal for EBT and increasing values were observed for DSCT and highest values for 64-slice MDCT. CMS was minimal for mass score and increasing values were observed for volume score and highest values for Agatston score. For all densities and scoring methods DSCT showed on average the closest resemblance to EBT calcium scores. When using the correction factor, CMS index decreased on average by 15% and Delta index

  5. A model for quantitative correction of coronary calcium scores on multidetector, dual source, and electron beam computed tomography for influences of linear motion, calcification density, and temporal resolution: A cardiac phantom study

    SciTech Connect

    Greuter, M. J. W.; Groen, J. M.; Nicolai, L. J.; Dijkstra, H.; Oudkerk, M.

    2009-11-15

    Purpose: The objective of this study is to quantify the influence of linear motion, calcification density, and temporal resolution on coronary calcium determination using multidetector computed tomography (MDCT), dual source CT (DSCT), and electron beam tomography (EBT) and to find a quantitative method which corrects for the influences of these parameters using a linear moving cardiac phantom. Methods: On a robotic arm with artificial arteries with four calcifications of increasing density, a linear movement was applied between 0 and 120 mm/s (step of 10 mm/s). The phantom was scanned five times on 64-slice MDCT, DSCT, and EBT using a standard acquisition protocol. The average Agatston, volume, and mass scores were determined for each velocity, calcification, and scanner. Susceptibility to motion was quantified using a cardiac motion susceptibility (CMS) index. Resemblance to EBT and physical volume and mass was quantified using a {Delta} index. Results: Increasing motion artifacts were observed at increasing velocities on all scanners, with increasing severity from EBT to DSCT to 64-slice MDCT. The calcium score showed a linear dependency on motion from which a correction factor could be derived. This correction factor showed a linear dependency on the mean calcification density with a good fit for all three scoring methods and all three scanners (0.73{<=}R{sup 2}{<=}0.95). The slope and offset of this correction factor showed a linear dependency on temporal resolution with a good fit for all three scoring methods and all three scanners (0.83{<=}R{sup 2}{<=}0.98). CMS was minimal for EBT and increasing values were observed for DSCT and highest values for 64-slice MDCT. CMS was minimal for mass score and increasing values were observed for volume score and highest values for Agatston score. For all densities and scoring methods DSCT showed on average the closest resemblance to EBT calcium scores. When using the correction factor, CMS index decreased on average by

  6. Factors affecting engagement of dual diagnosis patients in outpatient treatment.

    PubMed

    Bogenschutz, M P; Siegfreid, S L

    1998-10-01

    This study examined factors associated with engagement in outpatient treatment of patients with dual diagnoses of psychiatric disorder and substance use disorder. The charts of all 57 patients referred to a dual diagnosis treatment program during a six-month period were reviewed, and data on patients' substance use diagnosis, psychiatric diagnosis, sex, ethnicity, and referral source were collected. Patients referred from inpatient treatment were more likely to attend three or more appointments at the dual diagnosis program than those referred from outpatient treatment. Substance of abuse interacted with both referral source and sex in predicting engagement.

  7. Dual Credit/Dual Enrollment and Data Driven Policy Implementation

    ERIC Educational Resources Information Center

    Lichtenberger, Eric; Witt, M. Allison; Blankenberger, Bob; Franklin, Doug

    2014-01-01

    The use of dual credit has been expanding rapidly. Dual credit is a college course taken by a high school student for which both college and high school credit is given. Previous studies provided limited quantitative evidence that dual credit/dual enrollment is directly connected to positive student outcomes. In this study, predictive statistics…

  8. Dual Credit/Dual Enrollment and Data Driven Policy Implementation

    ERIC Educational Resources Information Center

    Lichtenberger, Eric; Witt, M. Allison; Blankenberger, Bob; Franklin, Doug

    2014-01-01

    The use of dual credit has been expanding rapidly. Dual credit is a college course taken by a high school student for which both college and high school credit is given. Previous studies provided limited quantitative evidence that dual credit/dual enrollment is directly connected to positive student outcomes. In this study, predictive statistics…

  9. Bifocal dual reflector antenna

    NASA Technical Reports Server (NTRS)

    Rao, B. L. J.

    1973-01-01

    A bifocal dual reflector antenna is similar to and has better scan capability than classical cassegrain reflector antenna. The method used in determining the reflector surfaces is a modification of a design method for the dielectric bifocal lens. The three dimensional dual reflector is obtained by first designing an exact (in geometrical optics sense) two-point corrected two dimensional reflector and then rotating it around its axis of symmetry. A point by point technique is used in computing the reflector surfaces. Computed radiation characteristics of the dual reflector are compared with those of a cassegrain reflector. The results confirm that the bifocal antenna has superior performance.

  10. Second-generation dual-energy computed tomography of the abdomen: radiation dose comparison with 64- and 128-row single-energy acquisition.

    PubMed

    De Cecco, Carlo Nicola; Darnell, Anna; Macías, Napoleón; Ayuso, Juan Ramón; Rodríguez, Sonia; Rimola, Jordi; Pagés, Mario; García-Criado, Ángeles; Rengo, Marco; Muscogiuri, Giuseppe; Laghi, Andrea; Ayuso, Carmen

    2013-01-01

    This study was designed to compare the radiation dose in abdominal dual-energy (DE) and single-energy (SE) acquisitions obtained in clinical practice with a second-generation DE computed tomography (DECT) and to analyze the dose variation in comparison with an SE acquisition performed with a 64-row SECT (SECT). A total of 130 patients divided into 2 groups underwent precontrast and portal abdominal 128-row CT examination. In group A, DE portal acquisition was performed using a detector configuration of 2 × 40 × 0.6 mm, tube A at 80 kVp and a reference value of 559 mAs, tube B at 140 kVp and a reference value of 216 mAs, pitch 0.6, and online dose modulation; group B underwent SE portal acquisition using a detector configuration of 64 × 0.6 mm, 120 kVp and a reference value of 180 mAs, pitch 0.75, and online dose modulation. Group C consisted of 32 subjects from group A previously studied with 64-row SECT using the following parameters: detector configuration 64 × 0.6 mm, 120 kVp and a reference value of 180 mAs, pitch 0.75, and online dose modulation. In each group, the portal phase dose-length product and radiation dose (mSv) were calculated and normalized for a typical abdominal acquisition of 40 cm. After normalization to standard 40-cm acquisition, a dose-length product of 599.0 ± 133.5 mGy · cm (range, 367.5 ± 1231.2 mGy · cm) in group A, 525.9 ± 139.2 mGy · cm (range, 215.7-882.8 mGy · cm) in group B, and 515.9 ± 111.3 mGy · cm (range, 305.5-687.2 mGy · cm) in group C was calculated for portal phase acquisition.A significant radiation dose increase (P < 0.05) was observed in group A (10.2 ± 2.3 mSv) compared with group B (8.9 ± 2.4) and group C (8.8 ± 1.9 mSv). No significant difference (P > 0.05) was reported between SE 64- and 128-row acquisitions. A significant positive correlation between radiation dose and body mass index was observed in each group (group A, r = 0.59, P < 0.0001; group B, r = 0.35, P < 0.0001; group C, r = 0.20, P = 0

  11. "How to" incorporate dual-energy imaging into a high volume abdominal imaging practice.

    PubMed

    Tamm, Eric P; Le, Ott; Liu, Xinming; Layman, Rick R; Cody, Dianna D; Bhosale, Priya R

    2017-03-01

    Dual-energy CT imaging has many potential uses in abdominal imaging. It also has unique requirements for protocol creation depending on the dual-energy scanning technique that is being utilized. It also generates several new types of images which can increase the complexity of image creation and image interpretation. The purpose of this article is to review, for rapid switching and dual-source dual-energy platforms, methods for creating dual-energy protocols, different approaches for efficiently creating dual-energy images, and an approach to navigating and using dual-energy images at the reading station all using the example of a pancreatic multiphasic protocol. It will also review the three most commonly used types of dual-energy images: "workhorse" 120kVp surrogate images (including blended polychromatic and 70 keV monochromatic), high contrast images (e.g., low energy monochromatic and iodine material decomposition images), and virtual unenhanced images. Recent developments, such as the ability to create automatically on the scanner the most common dual-energy images types, namely new "Mono+" images for the DSDECT (dual-source dual-energy CT) platform will also be addressed. Finally, an approach to image interpretation using automated "hanging protocols" will also be covered. Successful dual-energy implementation in a high volume practice requires careful attention to each of these steps of scanning, image creation, and image interpretation.

  12. Dual-mode capability for hardware-in-the-loop

    NASA Astrophysics Data System (ADS)

    Vamivakas, A. N.; Jackson, Ron L.

    2000-07-01

    This paper details a Hardware-in-the-Loop Facility (HIL) developed for evaluation and verification of a missile system with dual mode capability. The missile has the capability of tracking and intercepting a target using either an RF antenna or an IR sensor. The testing of a dual mode system presents a significant challenge in the development of the HIL facility. An IR and RF target environment must be presented simultaneously to the missile under test. These targets, simulated by IR and RF sources, must be presented to the missile under test without interference from each other. The location of each source is critical in the development of the HIL facility. The requirements for building a HIL facility with dual mode capability and the methodology for testing the dual mode system are defined within this paper. Methods for the verification and validation of the facility are discussed.

  13. Dual manifold heat pipe evaporator

    DOEpatents

    Adkins, Douglas R.; Rawlinson, K. Scott

    1994-01-01

    An improved evaporator section for a dual manifold heat pipe. Both the upper and lower manifolds can have surfaces exposed to the heat source which evaporate the working fluid. The tubes in the tube bank between the manifolds have openings in their lower extensions into the lower manifold to provide for the transport of evaporated working fluid from the lower manifold into the tubes and from there on into the upper manifold and on to the condenser portion of the heat pipe. A wick structure lining the inner walls of the evaporator tubes extends into both the upper and lower manifolds. At least some of the tubes also have overflow tubes contained within them to carry condensed working fluid from the upper manifold to pass to the lower without spilling down the inside walls of the tubes.

  14. Dual manifold heat pipe evaporator

    DOEpatents

    Adkins, D.R.; Rawlinson, K.S.

    1994-01-04

    An improved evaporator section is described for a dual manifold heat pipe. Both the upper and lower manifolds can have surfaces exposed to the heat source which evaporate the working fluid. The tubes in the tube bank between the manifolds have openings in their lower extensions into the lower manifold to provide for the transport of evaporated working fluid from the lower manifold into the tubes and from there on into the upper manifold and on to the condenser portion of the heat pipe. A wick structure lining the inner walls of the evaporator tubes extends into both the upper and lower manifolds. At least some of the tubes also have overflow tubes contained within them to carry condensed working fluid from the upper manifold to pass to the lower without spilling down the inside walls of the tubes. 1 figure.

  15. Dual-Mode Combustor

    NASA Technical Reports Server (NTRS)

    Trefny, Charles J (Inventor); Dippold, Vance F (Inventor)

    2013-01-01

    A new dual-mode ramjet combustor used for operation over a wide flight Mach number range is described. Subsonic combustion mode is usable to lower flight Mach numbers than current dual-mode scramjets. High speed mode is characterized by supersonic combustion in a free-jet that traverses the subsonic combustion chamber to a variable nozzle throat. Although a variable combustor exit aperture is required, the need for fuel staging to accommodate the combustion process is eliminated. Local heating from shock-boundary-layer interactions on combustor walls is also eliminated.

  16. Optical system design of dual-spectrum autocollimator

    NASA Astrophysics Data System (ADS)

    Wei, Yongjing; Wu, Yiming; Xiao, Maosen; Lu, Weiguo

    2015-10-01

    The optical system design of a new dual-spectrum autocollimator which can measure two different spatial azimuths simultaneously is proposed. According to the principle of dual-spectrum autocollimator, ZEMAX software is used to design and optimize the optical system. Since two light sources with different wavelength are used in the autocollimator, chromatic aberration is required to reduce off in the optical system design. The experimental results demonstrate that the measuring range of the dual-spectrum autocollimator is up to +/-30', the deviation is less than 1″, and the resolution can reach 0.1". The designed autocollimator can simultaneously measure two different azimuths fastly and accurately.

  17. Dual approximations in optimal control

    NASA Technical Reports Server (NTRS)

    Hager, W. W.; Ianculescu, G. D.

    1984-01-01

    A dual approximation for the solution to an optimal control problem is analyzed. The differential equation is handled with a Lagrange multiplier while other constraints are treated explicitly. An algorithm for solving the dual problem is presented.

  18. Dual Coding in Children.

    ERIC Educational Resources Information Center

    Burton, John K.; Wildman, Terry M.

    The purpose of this study was to test the applicability of the dual coding hypothesis to children's recall performance. The hypothesis predicts that visual interference will have a small effect on the recall of visually presented words or pictures, but that acoustic interference will cause a decline in recall of visually presented words and…

  19. Dual beam optical interferometer

    NASA Technical Reports Server (NTRS)

    Gutierrez, Roman C. (Inventor)

    2003-01-01

    A dual beam interferometer device is disclosed that enables moving an optics module in a direction, which changes the path lengths of two beams of light. The two beams reflect off a surface of an object and generate different speckle patterns detected by an element, such as a camera. The camera detects a characteristic of the surface.

  20. Acute vertebral fracture after spinal fusion: a case report illustrating the added value of single-source dual-energy computed tomography to magnetic resonance imaging in a patient with spinal Instrumentation.

    PubMed

    Fuchs, M; Putzier, M; Pumberger, M; Hermann, K G; Diekhoff, T

    2016-09-01

    Magnetic resonance imaging (MRI) is degraded by metal-implant-induced artifacts when used for the diagnostic assessment of vertebral compression fractures in patients with instrumented spinal fusion. Dual-energy computed tomography (DECT) offers a promising supplementary imaging tool in these patients. This case report describes an 85-year-old woman who presented with a suspected acute vertebral fracture after long posterior lumbar interbody fusion. This is the first report of a vertebral fracture that showed bone marrow edema on DECT; however, edema was missed by an MRI STIR sequence owing to metal artifacts. Bone marrow assessment using DECT is less susceptible to metal artifacts than MRI, resulting in improved visualization of vertebral edema in the vicinity of fused vertebral bodies.

  1. Dual use research: investigation across multiple science disciplines.

    PubMed

    Oltmann, Shannon

    2015-04-01

    Most recent studies of dual use research have focused on the life sciences, although some researchers have suggested that dual use research occurs across many disciplines. This research is an initial investigation into the prevalence of dual use research in other scientific disciplines by surveying senior editors of scientific journals, drawn from Journal Citation Reports. The survey was emailed to 7,500 journal editors with a response rate of 10.1 %. Approximately 4.8 % of life science editors reported they had to consider whether to publish dual use research and 38.9 % said they decided to not publish the research in question. In disciplines other than the life sciences, 7.2 % of editors from other science disciplines reported that they had to consider whether to publish dual use research, and 48.4 % declined to publish it. The survey investigated relationships between dual use and the journal's source of funding and place of publication, but no relationships were found. Further research is needed to better understand the occurrence of dual use research in other science disciplines.

  2. Dual frequency comb metrology with one fiber laser

    NASA Astrophysics Data System (ADS)

    Zhao, Xin; Takeshi, Yasui; Zheng, Zheng

    2016-11-01

    Optical metrology techniques based on dual optical frequency combs have emerged as a hotly studied area targeting a wide range of applications from optical spectroscopy to microwave and terahertz frequency measurement. Generating two sets of high-quality comb lines with slightly different comb-tooth spacings with high mutual coherence and stability is the key to most of the dual-comb schemes. The complexity and costs of such laser sources and the associated control systems to lock the two frequency combs hinder the wider adoption of such techniques. Here we demonstrate a very simple and rather different approach to tackle such a challenge. By employing novel laser cavity designs in a mode-locked fiber laser, a simple fiber laser setup could emit dual-comb pulse output with high stability and good coherence between the pulse trains. Based on such lasers, comb-tooth-resolved dual-comb optical spectroscopy is demonstrated. Picometer spectral resolving capability could be realized with a fiber-optic setup and a low-cost data acquisition system and standard algorithms. Besides, the frequency of microwave signals over a large range can be determined based on a simple setup. Our results show the capability of such single-fiber-laser-based dual-comb scheme to reduce the complexity and cost of dual-comb systems with excellent quality for different dual-comb applications.

  3. GOES-R Dual Isolation

    NASA Technical Reports Server (NTRS)

    Freesland, Doug; Carter, Delano; Chapel, Jim; Clapp, Brian; Howat, John; Krimchansky, Alexander

    2015-01-01

    The Geostationary Operational Environmental Satellite-R Series (GOES-R) is the first of the next generation geostationary weather satellites, scheduled for delivery in late 2015. GOES-R represents a quantum increase in Earth and solar weather observation capabilities, with 4 times the resolution, 5 times the observation rate, and 3 times the number of spectral bands for Earth observations. With the improved resolution, comes the instrument suite's increased sensitive to disturbances over a broad spectrum 0-512 Hz. Sources of disturbance include reaction wheels, thruster firings for station keeping and momentum management, gimbal motion, and internal instrument disturbances. To minimize the impact of these disturbances, the baseline design includes an Earth Pointed Platform (EPP), a stiff optical bench to which the two nadir pointed instruments are collocated together with the Guidance Navigation & Control (GN&C) star trackers and Inertial Measurement Units (IMUs). The EPP is passively isolated from the spacecraft bus with Honeywell D-Strut isolators providing attenuation for frequencies above approximately 5 Hz in all six degrees-of-freedom. A change in Reaction Wheel Assembly (RWA) vendors occurred very late in the program. To reduce the risk of RWA disturbances impacting performance, a secondary passive isolation system manufactured by Moog CSA Engineering was incorporated under each of the six 160 Nms RWAs, tuned to provide attenuation at frequencies above approximately 50 Hz. Integrated wheel and isolator testing was performed on a Kistler table at NASA Goddard Space Flight Center. High fidelity simulations were conducted to evaluate jitter performance for four topologies: 1) hard mounted no isolation, 2) EPP isolation only, 2) RWA isolation only, and 4) dual isolation. Simulation results demonstrate excellent performance relative to the pointing stability requirements, with dual isolated Line of Sight (LOS) jitter less than 1 micron rad.

  4. Performance in Dual Tasks.

    DTIC Science & Technology

    1984-02-29

    Continue on reverse aide it neceeay and identify by block nualtber) Problem solving, attention , computer simulation, choice reaction time ...construct a single theoretical framework for the analysis of problem solving and real time 4attention and performance’ behavior. Such a model has been...the "production system * approach. The program has been used to simulate results from choice reaction time , stimulus repetition, dual channel

  5. Are Dual Periodicities at Saturn Really, Really Real?

    NASA Astrophysics Data System (ADS)

    Carbary, J. F.

    2011-12-01

    Since the discovery of dual periodicities in Saturn's kilometric radiation (SKR), similar dual periods have been putatively observed in energetic charged particles, energetic neutral atoms, low energy plasma, and magnetic field oscillations. Ostensibly, one period (~10.8 hours) derives from a source in the southern hemisphere, while the second period (~10.6 hours) derives from a source in the northern hemisphere. Recent work on SKR, however, has demonstrated that at least southern SKR simultaneously oscillates at both frequencies. Recent work in the magnetic field oscillations further indicates that dual periodicities can sporadically arise from "beating" of Cassini's orbit with the single southern period. A rotating spiral configuration of the plasma sheet can readily produce dual periods in energetic particle data when considered along the Cassini trajectory. Furthermore, solar wind modulation at ~26 days of any "carrier" phenomena at ~10.7 hours will generate a dual frequency spectrum very similar to that observed in the SKR, as well as Saturn's particles and fields. This presentation suggests that Saturn's magnetosphere really has only one fundamental (carrier) period and that dual (or even multiple) periodicities arise when this fundamental is amplitude-modulated by an external driver such as the solar wind, Titan, or even the orbit of Cassini!

  6. The DUAL mission concept

    NASA Astrophysics Data System (ADS)

    von Ballmoos, Peter; Alvarez, Jose; Barriere, Nicolas; Boggs, Steve; Bykov, Andrei; Del Cura Velayos, Juan Manuel; Frontera, Filippo; Hanlon, Lorraine; Hernanz, Margarita; Hinglais, Emmanuel; Isern, Jordi; Jean, Pierre; Knödlseder, Jürgen; Kuiper, Lucien; Leising, Mark; Pirard, Benoît; Prost, Jean-Pierre; da Silva, Rui; Takahashi, Tadayuki; Tomsick, John; Walter, Roland; Zoglauer, Andreas

    2011-09-01

    DUAL will study the origin and evolution of the elements and explores new frontiers of physics: extreme energies that drive powerful stellar explosions and accelerate particles to macroscopic energies; extreme densities that modify the laws of physics around the most compact objects known; and extreme fields that influence matter in a way that is unknown on Earth. The variability of these extreme objects requires continuous all-sky coverage, while detailed study demands an improvement in sensitivity over previous technologies by at least an order of magnitude. The DUAL payload is composed of an All-Sky Compton Imager (ASCI), and two optical modules, the Laue-Lens Optic (LLO) and the Coded-Mask Optic (CMO). The ASCI serves dual roles simultaneously, both as an optimal focal-plane sensor for deep observations with the optical modules and as a sensitive true all-sky telescope in its own right for all-sky surveys and monitoring. While the optical modules are located on the main satellite, the All-Sky Compton Imager is situated on a deployable structure at a distance of 30 m from the satellite. This configuration not only permits to maintain the less massive payload at the focal distance, it also greatly reduces the spacecraft-induced detector background, and, above all it provides ASCI with a continuous all-sky exposure.

  7. Dual-Schemata Model

    NASA Astrophysics Data System (ADS)

    Taniguchi, Tadahiro; Sawaragi, Tetsuo

    In this paper, a new machine-learning method, called Dual-Schemata model, is presented. Dual-Schemata model is a kind of self-organizational machine learning methods for an autonomous robot interacting with an unknown dynamical environment. This is based on Piaget's Schema model, that is a classical psychological model to explain memory and cognitive development of human beings. Our Dual-Schemata model is developed as a computational model of Piaget's Schema model, especially focusing on sensori-motor developing period. This developmental process is characterized by a couple of two mutually-interacting dynamics; one is a dynamics formed by assimilation and accommodation, and the other dynamics is formed by equilibration and differentiation. By these dynamics schema system enables an agent to act well in a real world. This schema's differentiation process corresponds to a symbol formation process occurring within an autonomous agent when it interacts with an unknown, dynamically changing environment. Experiment results obtained from an autonomous facial robot in which our model is embedded are presented; an autonomous facial robot becomes able to chase a ball moving in various ways without any rewards nor teaching signals from outside. Moreover, emergence of concepts on the target movements within a robot is shown and discussed in terms of fuzzy logics on set-subset inclusive relationships.

  8. Dual diagnosis in Spain.

    PubMed

    Gual, Antoni

    2007-01-01

    Our aim is to describe the current situation regarding the diagnosis and treatment of addiction in a variety of settings in Spain. Four-hundred and twenty-seven physicians known to treat addicted patients in non-private settings were recruited and agreed to participate. Each physician provided clinical and anonymous information on the first 6 consecutive patients who attended on a scheduled day. A total of 2361 patients were interviewed (92.1%) and data were obtained concerning gender, age, work, educational level, civil status, addiction diagnosis, type of treatment and psychiatric comorbidity. Seven-hundred and ninety-eight out of 2361 addicts (33.8%) presented with a dual diagnosis. Depression was the most prevalent disorder (21.6%), followed by anxiety disorders (11.7%). Comorbidity was found to be related to age, female gender, divorce and widowhood, and higher educational levels. Alcoholics who abused other drugs showed the highest rates of comorbidity (48.5%), while opiate addicts were at the lower end of the spectrum (27.4%). No differences were found related to the treatment setting, the doctor's medical specialty, or the geographical area. Finally, doctors tended to perceive that dual diagnosis was related to a worse psychiatric prognosis but not to higher relapse rates. Antidepressants were the most commonly prescribed drugs (62.4% of co-morbid patients) and anticraving agents were prescribed equally to comorbid and non-comorbid patients. Within the limitations of a descriptive study, our data show that comorbidity is a common clinical problem in patients who access addiction treatment. Affective and anxiety disorders are the most common comorbid diseases, and comorbidity rates seem to be unrelated to regional differences, medical settings or doctor's professional background. Dual diagnosis patients thus account for one third of the clinical workload of addiction specialists in Spain.

  9. Dual mode warhead

    SciTech Connect

    Obrsky, J.; Alexander, A.A.; Griffen, O.H.; Foster, J.S.; Shamblen, M.

    1980-12-31

    A dual mode warhead is provided for use against both soft and hard targets and capable of sensing which type of target has been struck comprising a casing made of a ductile material containing an explosive charge and a fuze assembly. The ductile warhead casing will mushroom and later split upon striking a hard target while still confining the explosive. Proper ductility and confinement are necessary for fuze sensing. The fuze assembly contains a pair of parallel firing trains, one initiated only by high and one by low impact deceleration. The firing train actuated by low impact deceleration contains a pyrotechnic delay to allow penetration of soft targets.

  10. Dual modification of biomolecules.

    PubMed

    Maruani, Antoine; Richards, Daniel A; Chudasama, Vijay

    2016-07-14

    With the advent of novel bioorthogonal reactions and "click" chemistry, an increasing number of strategies for the single labelling of proteins and oligonucleotides have emerged. Whilst several methods exist for the site-selective introduction of a single chemical moiety, site-selective and bioorthogonal dual modification of biomolecules remains a challenge. The introduction of multiple modules enables a plethora of permutations and combinations and can generate a variety of bioconjuguates with many potential applications. From de novo approaches on oligomers to the post-translational functionalisation of proteins, this review will highlight the main strategies to dually modify biomolecules.

  11. Dual stage check valve

    NASA Technical Reports Server (NTRS)

    Whitten, D. E. (Inventor)

    1973-01-01

    A dual stage seat valve head arrangement is described which consists of a primary sealing point located between a fixed orifice seat and a valve poppet, and a secondary sealing point between an orifice poppet and a valve poppet. Upstream of the valve orifice is a flexible, convoluted metal diaphragm attached to the orifice poppet. Downstream of the valve orifice, a finger spring exerts a force against the valve poppet, tending to keep the valve in a closed position. The series arrangement of a double seat and poppet is able to tolerate small particle contamination while minimizing chatter by controlling throttling or metering across the secondary seat, thus preserving the primary sealing surface.

  12. Dual-Anode Nickel/Hydrogen Cell

    NASA Technical Reports Server (NTRS)

    Gahn, Randall F.; Ryan, Timothy P.

    1994-01-01

    Use of two hydrogen anodes in nickel/hydrogen cell reduces ohmic and concentration polarizations contributing to internal resistance, yielding cell with improved discharging performance compared to single-anode cell. Dual-anode concept incorporated into nickel/hydrogen cells of individual pressure-vessel type (for use aboard spacecraft) and common pressure-vessel type, for use on Earth to store electrical energy from photovoltaic sources, "uninterruptible" power supplies of computer and telephone systems, electric vehicles, and load leveling on power lines. Also applicable to silver/hydrogen and other metal/gas batteries.

  13. Dual Relationships in Group Training

    ERIC Educational Resources Information Center

    Goodrich, Kristopher M.

    2008-01-01

    This article reviews and critiques the literature regarding dual relationships in group work training. It explores the ethical concerns raised within the field, and relates this to an emerging literature concerning potentially beneficial relationships. Anecdotal and empirical evidence regarding dual relationships is reviewed, demonstrating the…

  14. Dual-Credit in Kentucky

    ERIC Educational Resources Information Center

    Stephenson, Lisa G.

    2013-01-01

    Credit-based transition programs provide high school students with opportunities to jump start their college education. The Kentucky Community and Technical College System (KCTCS) offers college credit through dual-credit programs. While KCTCS dual-credit offerings have been successful in helping high school students start their college education…

  15. Benefits of Dual Language Education

    ERIC Educational Resources Information Center

    Wallstrum, Kiara

    2009-01-01

    The focus of this paper examines how dual language education (DLE) programs are valuable. The literature shows that children do much more than just thrive in a dual language environment. According to research, children who are bilingual are cognitively, academically, intellectually, socially and verbally more advantaged than their monolingual…

  16. Dual-Credit in Kentucky

    ERIC Educational Resources Information Center

    Stephenson, Lisa G.

    2013-01-01

    Credit-based transition programs provide high school students with opportunities to jump start their college education. The Kentucky Community and Technical College System (KCTCS) offers college credit through dual-credit programs. While KCTCS dual-credit offerings have been successful in helping high school students start their college education…

  17. Dual redundant arm system operational quality measures and their applications - Dynamic measures

    NASA Technical Reports Server (NTRS)

    Lee, Sukhan; Kim, Sungbok

    1990-01-01

    Dual-arm dynamic operation quality measures are presented which quantify the efficiency and capability of generating Cartesian accelerations by two cooperative arms based on the analysis of dual-arm dynamic interactions. Dual-arm dynamic manipulability is defined as the efficiency of generating Cartesian accelerations under the dynamic and kinematic interactions between individual arms and an object under manipulation. The analysis of dual-arm dynamic interactions is based on the so-called Cartesian space agent model of an arm, which represents an individual arm as a force source acting upon a point mass with the effective Cartesian space arm dynamics and an environment or an object under manipulation. The Cartesian space agent model of an arm makes it possible to derive the dynamic and kinematic constraints involved in the transport, assembly and grasping modes of dual-arm cooperation. A task-oriented operational quality measure, (TOQd) is defined by evaluating dual-arm dynamic manipulability in terms of given task requirements. TOQd is used in dual-arm joint configuration optimization. Simulation results are shown. A complete set of forward dynamic equations for a dual-arm system is derived, and dual-arm dynamic operational quality measures for various modes of dual-arm cooperation allowing sliding contacts are established.

  18. Dual redundant arm system operational quality measures and their applications - Dynamic measures

    NASA Technical Reports Server (NTRS)

    Lee, Sukhan; Kim, Sungbok

    1990-01-01

    Dual-arm dynamic operation quality measures are presented which quantify the efficiency and capability of generating Cartesian accelerations by two cooperative arms based on the analysis of dual-arm dynamic interactions. Dual-arm dynamic manipulability is defined as the efficiency of generating Cartesian accelerations under the dynamic and kinematic interactions between individual arms and an object under manipulation. The analysis of dual-arm dynamic interactions is based on the so-called Cartesian space agent model of an arm, which represents an individual arm as a force source acting upon a point mass with the effective Cartesian space arm dynamics and an environment or an object under manipulation. The Cartesian space agent model of an arm makes it possible to derive the dynamic and kinematic constraints involved in the transport, assembly and grasping modes of dual-arm cooperation. A task-oriented operational quality measure, (TOQd) is defined by evaluating dual-arm dynamic manipulability in terms of given task requirements. TOQd is used in dual-arm joint configuration optimization. Simulation results are shown. A complete set of forward dynamic equations for a dual-arm system is derived, and dual-arm dynamic operational quality measures for various modes of dual-arm cooperation allowing sliding contacts are established.

  19. Toward Personhood: Uniting the Professional Woman's "Dual Careers."

    ERIC Educational Resources Information Center

    Lischin, Stevi; Smith, Robert Charles

    While professional women may experience their "dual careers" at home and at work as a source of inner fragmentation, this fragmentation can be a vehicle for developing a greater sense of personhood. Recent data show that women who combine work, marriage, and motherhood are experiencing more general psychological well being than are other women.…

  20. Chemical detection with hyperspectral lidar using dual frequency combs.

    PubMed

    Boudreau, Sylvain; Levasseur, Simon; Perilla, Carlos; Roy, Simon; Genest, Jérôme

    2013-03-25

    High-resolution spectral lidar measurements using dual frequency combs as a source is presented. The technique enables the range-resolved measurement of fine spectral features, such as gas absorption lines, provided that a suitable scatterer is present in the scene. Measurements of HCN absorption lines at 20 meters are presented, with a water droplet cloud and a diffusely reflective surface as scatterers.

  1. Dual ion beam processed diamondlike films for industrial applications

    NASA Technical Reports Server (NTRS)

    Mirtich, M. J.; Kussmaul, M. T.; Banks, B. A.; Sovey, J. S.

    1991-01-01

    Single and dual beam ion source systems are used to generate amorphous diamondlike carbon (DLC) films, which were evaluated for a variety of applications including protective coatings on transmitting materials, power electronics as insulated gates and corrosion resistant barriers. A list of the desirable properties of DLC films along with potential applications are presented.

  2. The evaluation of dual cement resins in orthodontic bonding.

    PubMed

    Smith, R T; Shivapuja, P K

    1993-05-01

    Dual-cement resins are composite resins that are both light activated and chemically cured. They can be cured completely with a visible light source or by the catalyst and base reaction of the material. With the control of setting time, dual cements appear to offer clinicians advantages in orthodontic bonding. The purposes of the present research are to compare various dual cements in regard to orthodontic bonding and to evaluate them in relation to currently used chemically cured and light-cured composite resins for bonding stainless steel mesh-backed orthodontic brackets. Seven currently available orthodontic bonding systems (three light cured and four chemically cured) and three dual cements were evaluated. Each of the 10 groups contained 15 noncarious mandibular incisors. Mandibular incisor brackets were bonded to the teeth in accordance with the manufacturer's recommendation. After bonding, the teeth were stored for 5 days in water at 37 degrees C. An Instron machine (Instron Corp., Canton, Mass.) was used to test samples. All samples were compared with Concise orthodontic bonding composite (3M, St. Paul, Minn.). The results of this investigation show that it is possible to bond solid, mesh-backed metal orthodontic brackets to teeth with a dual cement. The shear bond strengths of the dual cements, as tested in the laboratory, should be adequate to withstand normal orthodontic forces. Increased control of the setting time of the dual cements will allow the clinician more time to correctly position brackets and to remove excess resin before curing. In addition, the clinician can be assured of complete polymerization with the chemical properties of the dual cement resins.

  3. Widely-tunable, Compact, and Portable Terahertz Source Based on Intracavity Difference-Frequency Generation in Dual-Frequency Yb:YAG Laser for Identification and Detection of Biological Agents

    DTIC Science & Technology

    2011-06-15

    2011 W911NF-11-C-0044 Period of Performance December 9, 2010 – June 6, 2011 “Widely-tunable, compact, and portable terahertz source based on...combination acoustic-optic and passive Q-switch for LIDAR applications,” JWA46, CLEO 2011. [5] Y. Jiang, D. Li, Y. J. Ding, and I. B. Zotova, “ Terahertz ...Generation Based on Parametric Conversion: From Saturation of Conversion Efficiency to Back Conversion,” Opt. Lett. 36, 1608-1610 (2011). [6] Q. Gan , Z

  4. Integrated Dual Imaging Detector

    NASA Technical Reports Server (NTRS)

    Rust, David M.

    1999-01-01

    A new type of image detector was designed to simultaneously analyze the polarization of light at all picture elements in a scene. The integrated Dual Imaging detector (IDID) consists of a lenslet array and a polarizing beamsplitter bonded to a commercial charge coupled device (CCD). The IDID simplifies the design and operation of solar vector magnetographs and the imaging polarimeters and spectroscopic imagers used, for example, in atmosphere and solar research. When used in a solar telescope, the vector magnetic fields on the solar surface. Other applications include environmental monitoring, robot vision, and medical diagnoses (through the eye). Innovations in the IDID include (1) two interleaved imaging arrays (one for each polarization plane); (2) large dynamic range (well depth of 10(exp 5) electrons per pixel); (3) simultaneous readout and display of both images; and (4) laptop computer signal processing to produce polarization maps in field situations.

  5. Dual-Mode Combustion

    NASA Technical Reports Server (NTRS)

    Goyne, Christopher P.; McDaniel, James C.

    2002-01-01

    The Department of Mechanical and Aerospace Engineering at the University of Virginia has conducted an investigation of the mixing and combustion processes in a hydrogen fueled dual-mode scramjet combustor. The experiment essentially consisted of the "direct connect" continuous operation of a Mach 2 rectangular combustor with a single unswept ramp fuel injector. The stagnation enthalpy of the test flow simulated a flight Mach number of 5. Measurements were obtained using conventional wall instrumentation and laser based diagnostics. These diagnostics included, pressure and wall temperature measurements, Fuel Plume Imaging (FPI) and Particle Image Velocimetry (PIV). A schematic of the combustor configuration and a summary of the measurements obtained are presented. The experimental work at UVa was parallel by Computational Fluid Dynamics (CFD) work at NASA Langley. The numerical and experiment results are compared in this document.

  6. Dual broadband metamaterial absorber.

    PubMed

    Kim, Young Ju; Yoo, Young Joon; Kim, Ki Won; Rhee, Joo Yull; Kim, Yong Hwan; Lee, YoungPak

    2015-02-23

    We propose polarization-independent and dual-broadband metamaterial absorbers at microwave frequencies. This is a periodic meta-atom array consisting of metal-dielectric-multilayer truncated cones. We demonstrate not only one broadband absorption from the fundamental magnetic resonances but additional broadband absorption in high-frequency range using the third-harmonic resonance, by both simulation and experiment. In simulation, the absorption was over 90% in 3.93-6.05 GHz, and 11.64-14.55 GHz. The corresponding experimental absorption bands over 90% were 3.88-6.08 GHz, 9.95-10.46 GHz and 11.86-13.84 GHz, respectively. The origin of absorption bands was elucidated. Furthermore, it is independent of polarization angle owing to the multilayered circular structures. The design is scalable to smaller size for the infrared and the visible ranges.

  7. Dual Tank Fuel System

    DOEpatents

    Wagner, Richard William; Burkhard, James Frank; Dauer, Kenneth John

    1999-11-16

    A dual tank fuel system has primary and secondary fuel tanks, with the primary tank including a filler pipe to receive fuel and a discharge line to deliver fuel to an engine, and with a balance pipe interconnecting the primary tank and the secondary tank. The balance pipe opens close to the bottom of each tank to direct fuel from the primary tank to the secondary tank as the primary tank is filled, and to direct fuel from the secondary tank to the primary tank as fuel is discharged from the primary tank through the discharge line. A vent line has branches connected to each tank to direct fuel vapor from the tanks as the tanks are filled, and to admit air to the tanks as fuel is delivered to the engine.

  8. Miniaturized Dual-Band Bandpass Filter Using Embedded Dual-Mode Resonator with Controllable Bandwidths

    NASA Astrophysics Data System (ADS)

    Zhu, Chuanming; Xu, Jin; Kang, Wei; Hu, Zhenxin; Wu, Wen

    2016-09-01

    In this paper, a miniaturized dual-band bandpass filter (DB-BPF) using embedded dual-mode resonator (DMR) with controllable bandwidths is proposed. Two passbands are generated by two sets of resonators operating at two different frequencies. One set of resonators is utilized not only as the resonant elements that yield the lower passband, but also as the feeding structures with source-load coupling to excite the other to produce the upper passband. Sufficient degrees of freedom are achieved to control the center frequencies and bandwidths of two passbands. Moreover, multiple transmission zeros (TZs) are created to improve the passband selectivity of the filter. The design of the filter has been demonstrated by the measurement. The filter features not only miniaturized circuit sizes, low insertion loss, independently controllable central frequencies, but also controllable bandwidths and TZs.

  9. Scaling laws for dual radio-frequency capacitively coupled discharges

    SciTech Connect

    Chung, T.H.

    2005-10-01

    The characteristics of dual radio-frequency capacitively coupled discharges are studied based on a homogeneous analytic model. We are considering a planar plasma device that can be approximated using a one-dimensional model. A set of equations describing the dynamics of the system are presented and used to give the analytic scaling laws. Scaling laws relating the drive frequencies and the applied voltages of dual radio-frequency sources to operating functions such as plasma density and plasma potential are examined and compared with numerical simulations.

  10. Gravitational radiation from dual neutron star elliptical binaries

    NASA Technical Reports Server (NTRS)

    Hils, Dieter

    1991-01-01

    General expressions are derived for the gravitational radiation incident on earth due to elliptical binary systems in the Galaxy. These results are applied to dual neutron star elliptical binaries. Calculations show that eccentric dual neutron star binaries lead to a moderate increase in gravitational flux density compared with circular systems for frequencies above approximately 0.0001 Hz. Tables of various quantities such as average gravitational luminosity, number of sources per unit bandwidth, energy spectral flux density, and gravitational wave strain density are given.

  11. Dual-Phase Nozzle Flow.

    DTIC Science & Technology

    1982-10-01

    Two-phase 20. A T RACT (0.31lmm 401 teV9 i 01 000* u...in #CMIdR@0fr &V WNHI& WARNeJ A revieW or the dual-phase -ower system was made. This study ...pr-et5 ._ lnering Dean of Science and Engineering J* ABSTRACT A review of the dual-phase power system was made. This study focused on the multi...be studied in detail, but first a review of the dual-phase cycle will be carried out from information obtained from References 1 and 2. Reference 1