Science.gov

Sample records for 9-track magnetic tape

  1. Magnetic tape

    NASA Technical Reports Server (NTRS)

    Robinson, Harriss

    1992-01-01

    The move to visualization and image processing in data systems is increasing the demand for larger and faster mass storage systems. The technology of choice is magnetic tape. This paper briefly reviews the technology past, present, and projected. A case is made for standards and the value of the standards to users.

  2. Magnetic tape user guide

    NASA Technical Reports Server (NTRS)

    Evans, A. B.; Lee, L. L.

    1985-01-01

    This User Guide provides a general introduction to the structure, use, and handling of magnetic tapes at Langley Research Center (LaRC). The topics covered are tape terminology, physical characteristics, error prevention and detection, and creating, using, and maintaining tapes. Supplementary documentation is referenced where it might be helpful. The documentation is included for the tape utility programs, BLOCK, UNBLOCK, and TAPEDMP, which are available at the Central Scientific Computing Complex at LaRC.

  3. An improved magnetic tape recorder

    NASA Technical Reports Server (NTRS)

    Uber, P. W.

    1968-01-01

    Magnetic tape recorder employs a single capstan for simultaneously driving the supply and take-up reels in such a manner that the tape passing between the reels is kept under a predetermined constant tension. This recorder operates with little power and is sufficiently rugged to withstand the severe stresses encountered in high-altitude balloon flight tests.

  4. Superconducting flat tape cable magnet

    DOEpatents

    Takayasu, Makoto

    2015-08-11

    A method for winding a coil magnet with the stacked tape cables, and a coil so wound. The winding process is controlled and various shape coils can be wound by twisting about the longitudinal axis of the cable and bending following the easy bend direction during winding, so that sharp local bending can be obtained by adjusting the twist pitch. Stack-tape cable is twisted while being wound, instead of being twisted in a straight configuration and then wound. In certain embodiments, the straight length should be half of the cable twist-pitch or a multiple of it.

  5. Five year magnetic tape for unattended satellite tape recorders

    NASA Technical Reports Server (NTRS)

    Benn, G. S. L.; Gutfreund, K.

    1972-01-01

    The development and fabrication of a quantity of long life magnetic tape with properties selected specifically for unattended operation in spacecraft tape recorders was studied. A detailed analytical consideration of various binder systems was undertaken. This included the chemical aspects of the binders, cohesion and adhesion effects, stability and the mechanical and physical properties. The ability to form free films of these polymers and their combination with various oxide loadings and other additives allowed a rapid selection of four polymer candidates for a five year magnetic tape. Samples were evaluated under actual running conditions which included physical, magnetic, and extensive life testing. These sample tapes withstood 50,000 bidirectional tape passes under fairly harsh operating conditions.

  6. Magnetic evaluation of advanced metal-evaporated tape in an advanced linear tape drive

    NASA Astrophysics Data System (ADS)

    Alfano, Anthony D.; Bhushan, Bharat

    2007-01-01

    Demand for increased data storage has resulted in the development of various types of magnetic tapes. To achieve higher recording density, tape manufacturers are developing thin-film tapes, such as advanced metal-evaporated (AME) tape, for use in linear tape drives. In recent studies, these new AME tapes have demonstrated sustainable mechanical durability at low tensions suitable for use in linear tape drives. An evaluation of the magnetic performance of these AME tapes including the impact of tape cupping and initial edge quality was the goal of this study. Head output, dropouts, head-tape interface friction, and lateral tape motion (LTM) were monitored throughout testing. As track widths continue to narrow, LTM has become one of the critical limitations of magnetic performance. To more accurately measure LTM during drive development, a new method involving the output voltage of a head-read element that has been adjusted to be halfway off the recorded track on tape was implemented (LTM M). It is shown that positively cupped AME tapes will result in similar head output and fewer dropouts than the current MP tapes. The negatively cupped AME sample produced the lowest head output data and the highest amount of dropouts of all the tapes evaluated in this investigation. All the tapes evaluated demonstrated similar values of LTM when monitored at the center of the tape. When LTM was monitored at the lower edge of the tape, the positively cupped AME tape with the worst relative edge contour length resulted in the highest LTM M. As found in previous studies, AME tapes produced slightly lower values of coefficient of friction than the MP tapes. From this investigation, positively cupped AME tapes with good initial relative edge contour length are recommended for use in linear tape drives, similar to those used in this study.

  7. Using magnetic tape technology for data migration

    NASA Technical Reports Server (NTRS)

    Therrien, David; Cheung, Yim-Ling

    1993-01-01

    Magnetic tape and optical disk library units (jukeboxes) are satisfying the demand for high-capacity cost-effective storage. The choice between optical disk and magnetic tape technology must take into account the cost limitations as well as the performance and reliability requirements of the user environment. Library units require data management software in order to function in an automated and user-transparent way. The most common data management applications are backup and recovery, data migration, and archiving. The medium access patterns that these applications create will be described. Since the most user visible application is data migration, a queue simulator was developed to model its performance against a variety of library units. The major subject of this paper is the design and implementation of this simulator as well as some simulation results. The relative cost and reliability of magnetic tape versus optical disk library units is presented for completeness.

  8. 21 CFR 870.2800 - Medical magnetic tape recorder.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Medical magnetic tape recorder. 870.2800 Section 870.2800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... magnetic tape recorder. (a) Identification. A medical magnetic tape recorder is a device used to record...

  9. 21 CFR 870.2800 - Medical magnetic tape recorder.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Medical magnetic tape recorder. 870.2800 Section... (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2800 Medical magnetic tape recorder. (a) Identification. A medical magnetic tape recorder is a device used to record...

  10. Pollution prevention in the magnetic tape industry: Waterborne coating formulations for video tape manufacture

    SciTech Connect

    Cheng, S.; Fan, H.; Gogineni, N.; Jacobs, B.; Harrell, J.W.; Jefcoat, I.A.; Lane, A.M.; Nikles, D.E.

    1995-12-31

    A waterborne magnetic tape coating formulation was designed and used to prepare experimental magnetic tape samples in a pilot coating trial. The formulations contained a blend of a water-dispersed polyester and an ethylene/vinyl chloride copolymer emulsion, cross-linked with melamine-formaldehyde to give tensile properties (tensile strength 8.69 MPa Young`s modulus 245 MPa) that were comparable to a standard solvent-based binder composition. The pilot tape trial used existing processing equipment, including calendering and slitting. The tape had good magnetic properties and excellent adhesion between the pigmented magnetic layer and the base film, easily exceeding the 8 mm helical scan tape standard of 0.96 N peel force. An economic impact analysis for the case of sing the waterborne video tape coating process in a conventional tape manufacturing plant showed a significant decrease in costs for adopting the waterborne process.

  11. Magnetic tape recorder for long operating life in space.

    NASA Technical Reports Server (NTRS)

    Bahm, E. J.; Hoffman, J. K.

    1971-01-01

    Magnetic tape recorders have long been used on satellites and spacecraft for onboard storage of large quantities of data. As satellites enter into commercial service, long operating life at high reliability becomes important. Also, the presently planned long-duration space flights to the outer planets require long-life tape recorders. Past satellite tape recorders have achieved a less than satisfactory performance record and the operating life of other spacecraft tape recorders has been relatively short and unpredictable. Most failures have resulted from malfunctions of the mechanical tape transport. Recent advances in electric motors and static memories have allowed the development of a new tape recorder which uses a very simple tape transport with few possible failure modes. It consists only of two brushless dc motors, two tape guides, and the recording heads. Relatively low tape tension, wide torque capability, and precise speed control facilitate design for mechanical reliability to match that of tape-recorder electronics.

  12. Read/write head for a magnetic tape device having grooves for reducing tape floating

    DOEpatents

    Aoki, Kenji

    2005-08-09

    A read/write head for a magnetic tape includes an elongated chip assembly and a tape running surface formed in the longitudinal direction of the chip assembly. A pair of substantially spaced parallel read/write gap lines for supporting read/write elements extend longitudinally along the tape running surface of the chip assembly. Also, at least one groove is formed on the tape running surface on both sides of each of the read/write gap lines and extends substantially parallel to the read/write gap lines.

  13. Star Catalogs on Punched Cards and Magnetic Tape

    NASA Technical Reports Server (NTRS)

    Berbert, J. H.

    1961-01-01

    In connection with the calibration of the Minitrack satellite tracking stations, the Goddard Space Flight Center has had the contents of a number of star catalogs put on punched cards and magnetic tape. This report discusses the plate data reduction procedures, briefly describes the information on the punched cards and magnetic tape, and calls attention to other applications of the card and tape star catalogs. The Goddard Space Flight Center has offered to prepare duplicate catalogs for qualified organizations.

  14. GSFC specification electronic data processing magnetic recording tape

    NASA Technical Reports Server (NTRS)

    Tinari, D. F.; Perry, J. L.

    1980-01-01

    The design requirements are given for magnetic oxide coated, electronic data processing tape, wound on reels. Magnetic recording tape types covered by this specification are intended for use on digital tape transports using the Non-Return-to-Zero-change-on-ones (NRZI) recording method for recording densities up to and including 800 characters per inch (cpi) and the Phase-Encoding (PE) recording method for a recording density of 1600 cpi.

  15. Technique for recovery of voice data from heat damaged magnetic tape

    NASA Technical Reports Server (NTRS)

    Melugin, J. F.; Obrien, D. E., III (Inventor)

    1974-01-01

    A method for conditioning, and thus enabling retrieval of intelligence from, magnetic tapes after damage from heat has caused the tape to wrinkle and curl severely thereby reducing tape width to less than one-half its original size. The damaged tape is superposed on a first piece of splicing tape with the oxide side of the magnetic tape in contact with the adhesive side of the splicing tape and then carefully smoothed by a special tool. A second piece of splicing tape is placed on the backing side of the magnetic tape then the resulting tape stack is trimmed to the original width of the magnetic tape. After the first piece of splicing tape is carefully removed from the oxide side of the damaged magnetic tape, the resulting magnetic tape is then ready to be placed into a recorder for playback.

  16. Portable digital pressure indicator for calibrating magnetic tape recorders

    NASA Technical Reports Server (NTRS)

    Mccormick, Royce F.; Leighty, Bradley D.

    1989-01-01

    The design of a portable Digital Pressure Indicator (DPI) to be used for calibrating the pressure systems on Langley's magnetic tape recorders is described. High-speed magnetic tape recorders require pressure (0 to 20 psig) for providing an air cushion across the tape guides and a slight vacuum (30 inch H2O) for maintaining the proper number of tape loops in the advance and feed chamber. The DPI is a hand-held device that can be quickly coupled to a magnetic tape recorder and includes a two-position switch for selecting either measured pressure or vacuum, to be displayed digitally in engineering units (psig or inches H2O). The DPI is currently in use in Langley's Analysis and Computation Division.

  17. Critical Current Measurements in Commercial Tapes, Coils, and Magnets.

    NASA Astrophysics Data System (ADS)

    Gubser, D. U.; Soulen, R. J., Jr.; Fuller-Mora, W. W.; Francavilla, T. L.

    1996-03-01

    We have measured a number of tapes, coils, and magnets produced by commercial vendors and determined their properties as functions of magnetic field and temperature. The tapes were measured at the National High Magnetic Field Laboratory in magnetic fields to 20 tesla and at temperatures of 4.2 K, 27 K, 65 K, and 77 K. For the tapes we report critical currents and current-voltage characteristics. Six inch diameter coils were measured at NRL in zero magnetic field. Critical currents, current-voltage characteristics, and reliability studies are reported for the coils. Larger 10 inch diameter coils, which are to be used in a 200 hp superconducting motor, were also measured and results will be presented. The talk will also review the status of the most recent tests of the superconducting motor.

  18. Calibration tests on magnetic tape lightning current detectors

    NASA Astrophysics Data System (ADS)

    Crouch, K. E.

    1980-04-01

    The low cost, passive, peak lightning current detector (LCD) invented at the NASA/Kennedy Space Center, uses magnetic audio recording tape to sense the magnitude of the peak magnetic field around a conductor carrying lightning currents. Test results show that the length of audio tape erased was linearly related to the peak simulated lightning currents in a round conductor. Accuracies of + or - 10% were shown for measurements made using a stopwatch readout technique to determine the amount of tape erased by the lightning current. The stopwatch technique is a simple, low cost means of obtaining LCD readouts and can be used in the field to obtain immediate results. Where more accurate data are desired, the tape is played and the output recorded on a strip chart, oscilloscope, or some other means so that measurements can be made on that recording. Conductor dimensions, tape holder dimensions, and tape formulation must also be considered to obtain a more accurate result. If the shape of the conductor is other than circular (i.e., angle, channel, H-beam), an analysis of the magnetic field is required to use an LCD, especially at low current levels.

  19. Calibration tests on magnetic tape lightning current detectors

    NASA Technical Reports Server (NTRS)

    Crouch, K. E.

    1980-01-01

    The low cost, passive, peak lightning current detector (LCD) invented at the NASA/Kennedy Space Center, uses magnetic audio recording tape to sense the magnitude of the peak magnetic field around a conductor carrying lightning currents. Test results show that the length of audio tape erased was linearly related to the peak simulated lightning currents in a round conductor. Accuracies of + or - 10% were shown for measurements made using a stopwatch readout technique to determine the amount of tape erased by the lightning current. The stopwatch technique is a simple, low cost means of obtaining LCD readouts and can be used in the field to obtain immediate results. Where more accurate data are desired, the tape is played and the output recorded on a strip chart, oscilloscope, or some other means so that measurements can be made on that recording. Conductor dimensions, tape holder dimensions, and tape formulation must also be considered to obtain a more accurate result. If the shape of the conductor is other than circular (i.e., angle, channel, H-beam), an analysis of the magnetic field is required to use an LCD, especially at low current levels.

  20. 21 CFR 870.2800 - Medical magnetic tape recorder.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Medical magnetic tape recorder. 870.2800 Section 870.2800 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2800...

  1. Influence of technology on magnetic tape storage device characteristics

    NASA Technical Reports Server (NTRS)

    Gniewek, John J.; Vogel, Stephen M.

    1994-01-01

    There are available today many data storage devices that serve the diverse application requirements of the consumer, professional entertainment, and computer data processing industries. Storage technologies include semiconductors, several varieties of optical disk, optical tape, magnetic disk, and many varieties of magnetic tape. In some cases, devices are developed with specific characteristics to meet specification requirements. In other cases, an existing storage device is modified and adapted to a different application. For magnetic tape storage devices, examples of the former case are 3480/3490 and QIC device types developed for the high end and low end segments of the data processing industry respectively, VHS, Beta, and 8 mm formats developed for consumer video applications, and D-1, D-2, D-3 formats developed for professional video applications. Examples of modified and adapted devices include 4 mm, 8 mm, 12.7 mm and 19 mm computer data storage devices derived from consumer and professional audio and video applications. With the conversion of the consumer and professional entertainment industries from analog to digital storage and signal processing, there have been increasing references to the 'convergence' of the computer data processing and entertainment industry technologies. There has yet to be seen, however, any evidence of convergence of data storage device types. There are several reasons for this. The diversity of application requirements results in varying degrees of importance for each of the tape storage characteristics.

  2. Nanocluster deposition for high density magnetic recording tape media

    SciTech Connect

    Qiu Jiaoming; Xu Yunhao; Judy, Jack H.; Wang Jianping

    2005-05-15

    A technique for the fabrication of ultra-high density magnetic recording tape media with no risk of heating polymer substrate is reported. In this approach magnetic nanoparticles were generated by combining gas-phase nanocluster deposition and on-line heating techniques and deposited onto polymer substrate. Magnetic properties of the nanoparticles were optimized during their flight in vacuum prior to deposition. This technique is materials independent and it can fabricate nanocomposite films with high coercivity and very small film thickness. The fabricated magnetic nanoparticles have a uniform size distribution [for CoPt, 8.4% (standard deviation)] and well-defined spherical shape.

  3. Magnetic properties of Ni-based substrates for HTS tape

    NASA Astrophysics Data System (ADS)

    Claassen, J. H.; Thieme, C. L. H.

    2008-10-01

    Ni-W alloys are used as the substrate in the manufacture of HTS tape via the RABiTSTM process. Theoretical work has shown that the ferromagnetism in a substrate can affect the ac losses in the superconductor. This occurs in part because of the increased magnetic permeability, which alters the magnetic induction in the superconductor and thereby the loss. Magnetic hysteretic loss in the substrate is an additional contribution to overall ac loss. We report measurements of both permeability and magnetic loss as a function of frequency and magnetic induction for the standard alloy Ni-5W as well as composite substrates incorporating non-magnetic Ni-W alloys. The measurements are done using ac susceptibility at 77 K, at frequencies up to 104 Hz and inductions in the range 1-150 mT. It is shown how to use these results to predict total ac loss in isolated superconducting tape and wound coils. Some important magnetic parameters cannot be obtained with sufficient accuracy using a SQUID or vibrating sample magnetometer, since the size of a sample is limited in these measurements. This makes the demagnetizing factor large enough to degrade the accuracy of a permeability measurement.

  4. Field spectrometer (S191H) preprocessor tape quality test program design document

    NASA Technical Reports Server (NTRS)

    Campbell, H. M.

    1976-01-01

    Program QA191H performs quality assurance tests on field spectrometer data recorded on 9-track magnetic tape. The quality testing involves the comparison of key housekeeping and data parameters with historic and predetermined tolerance limits. Samples of key parameters are processed during the calibration period and wavelength cal period, and the results are printed out and recorded on an historical file tape.

  5. Programming input-output operations in FORTRAN on magnetic tape

    NASA Technical Reports Server (NTRS)

    Gorokov, V. N.

    1980-01-01

    The subprogram MTCFF was designed for carrying out input-output operations in FORTRAN on magnetic tape within the framework of the DOS ES EVM operation system. It is possible, by means of this subprogram, to perform any input-output operations of interest to the programmer such as recording and reading various control operations in the direct and reverse directions, even though for these purposes the facilities of the language FORTRAN itself are limited. The subprogram can also be used in programs written in other programming languages.

  6. Magnetic imaging of superconducting tapes to determine current flow

    SciTech Connect

    Brown, G. W.; Hawley, M. E.; Foltyn, S. R.; Mueller, F. M.

    2001-01-01

    We have developed a magnetic imaging system that uses magnetoresistive read heads from computer hard disk drives to map the transport-current-induced magnetic field at the surface of superconducting tapes at liquid nitrogen temperature. Transport current pathways are determined from the 2-dimensional magnetic field maps using established inversion schemes. We examined the current flow in pulsed-laser-deposited YBa{sub 2}Cu{sub 3}O{sub 7-{delta}} a films patterned on single crystal SrTiO{sub 3} substrates and on a textured yttria-stabilized-zirconia layer deposited on an Inconel ribbon by ion beam assisted deposition. The transport current densities in all cases were consistent with the Critical State Model. For the Inconel-based sample, the transport current density maps have allowed us to observe defects and determine the region that limits the current carrying capacity of the structure.

  7. Numerical simulation of screening current distribution in HTS tape of high field magnet

    NASA Astrophysics Data System (ADS)

    Itoh, Ryusei; Oga, Yuki; Noguchi, So; Igarashi, Hajime; Ueda, Hiroshi

    2013-01-01

    In recent years, properties of high temperature superconducting (HTS) tapes, especially in-field performance and mechanical strength, have been continuously improved. The HTS tapes have been widely used for high field (>20 T) magnet researches and there are several technical challenges including field attenuation of an HTS magnet by screening currents induced within the HTS tapes. Several publications reported that the screening currents, induced by penetration of self magnetic fields into HTS tapes within an HTS magnet, weakened a field constant of the HTS magnet. The result may demonstrate that the screening current changes an overall current density distribution in HTS tapes and, as a consequence, the generated magnetic field. Therefore, it is necessary to investigate the screening current distribution in an HTS tape. This paper reports numerical simulation of the screening current distribution in an HTS tape of high field magnets using 2D finite element method with the E-J characteristic of the HTS tape taken into account. Self magnetic field distribution and its orientation to the HTS tape are also considered to compute critical currents and locally generated electric fields, two key components to figure out the distribution of screening currents.

  8. Evolving Requirements for Magnetic Tape Data Storage Systems

    NASA Technical Reports Server (NTRS)

    Gniewek, John J.

    1996-01-01

    Magnetic tape data storage systems have evolved in an environment where the major applications have been back-up/restore, disaster recovery, and long term archive. Coincident with the rapidly improving price-performance of disk storage systems, the prime requirements for tape storage systems have remained: (1) low cost per MB, (2) a data rate balanced to the remaining system components. Little emphasis was given to configuring the technology components to optimize retrieval of the stored data. Emerging new applications such as network attached high speed memory (HSM), and digital libraries, place additional emphasis and requirements on the retrieval of the stored data. It is therefore desirable to consider the system to be defined both by STorage And Retrieval System (STARS) requirements. It is possible to provide comparative performance analysis of different STARS by incorporating parameters related to (1) device characteristics, and (2) application characteristics in combination with queuing theory analysis. Results of these analyses are presented here in the form of response time as a function of system configuration for two different types of devices and for a variety of applications.

  9. AC magnetic field losses in BSCCO-2223 superconducting tapes

    SciTech Connect

    Lelovic, M.; Mench, S.; Deis, T.

    1997-09-01

    The AC magnetic losses at power frequencies (60 Hz) were investigated for mono- and multifilament Ag-sheathed (Bi, Pb){sub 2}Sr{sub 2}Ca{sub 2}Cu{sub 3}O{sub y} (BSCCO-2223) tapes with similar transport critical current (I{sub c}) values at 77 K. The multifilament sample exhibited higher losses than the monofilament under the same conditions. Loss peaks are discussed in terms of intergranular, intragranular and eddy current losses. Because of BSCCO`s anisotropy, field orientation has a large effect on the magnitude of these peaks, even at relatively small angles. Losses for fields applied parallel to the c-axis of the textured BSCCO grains are larger by more than one order of magnitude than those applied perpendicular.

  10. Assessment of critical factors affecting the performance of trapped field magnets using thin film superconductor tapes

    NASA Astrophysics Data System (ADS)

    Selva, Kavita; Li, Xiao-Fen; Majkic, Goran; Masson, Philippe

    2015-12-01

    Trapped field magnets have been investigated using Zr-added (Gd,Y)Ba-Cu-O thin film superconductor tapes. Trapped field profiles were examined both experimentally and by simulation over a temperature range of 30 to 77 K. A good match is found between experimental and simulation trapped field data at 77 K and 65 K, but higher trapped field values were obtained experimentally at lower temperatures. Trapped field values up to 1.55 T were measured in an 11 mm thick stack of 55 μm thick superconductor tapes arranged in a crisscross fashion with three tapes per layer. A substantial increase in the trapped field values was found by simulation, in tape stacks made with 20 μm thick tapes. Using such thin tapes, trapped field values of nearly 2 T is predicted in ∼ 13 mm thick tape stacks at 77 K.

  11. Water-vapor effects on friction of magnetic tape in contact with nickel-zinc ferrite

    NASA Technical Reports Server (NTRS)

    Miyoshi, K.; Buckley, D. H.

    1984-01-01

    The effects of humidity of moist nitrogen on the friction and deformation behavior of magnetic tape in contact with a nickel-zinc ferrite spherical pin were studied. The results indicate that the coefficient of friction is markedly dependent on the ambient relative humidity. Although the coefficient of friction remains low below 40-percent relative humidity, it increases rapidly with increasing relative humidity above 40 percent. The general ambient environment of the tape does not have any effect on the friction behavior if the area where the tape is in sliding contact with the ferrite pin is flooded with controlled nitrogen. The response time for the friction of the tape to humidity changes is about 10 sec. The effect of friction as a function of relative humidity on dehumidifying is very similar to that on humidifying. A surface softening of the tape due to water vapor increases the friction of the tape.

  12. Intercomputer transfer in full precision of arbitrary data on magnetic tape employing NASTRAN user tape format

    NASA Technical Reports Server (NTRS)

    Rogers, J. L., Jr.

    1973-01-01

    A description is presented of two new utility programs which implement the transfer, in full precision, of arbitrary data (matrices or tables) between any of the three NASTRAN operative computers without the handling of large card decks. These computers include the CDC 6000 series, the IBM 360-370 series, and the Univac 1100 series. The data may be generated by NASTRAN or by another computer program if the NASTRAN user tape format is employed.

  13. Wide Temperature Magnetization Characteristics of Transverse Magnetically Annealed Amorphous Tapes for High Frequency Aerospace Magnetics

    NASA Technical Reports Server (NTRS)

    Niedra, Janis M.; Schwarze, Gene E.

    1999-01-01

    100 kHz magnetization properties of sample transverse magnetically annealed, cobalt-based amorphous and iron-based nanocrystalline tape wound magnetic cores are presented over the temperature range of -150 C to 150 C, at selected values of B(sub peak). Frequency resolved characteristics are given over the range of 50 kHz to 1 MHz, but at B(sub peak) = 0.1 T and 50 C only. Basic exciting winding current and induced voltage data were taken on bare toroidal cores, in a standard type measurement setup. A linear permeability model, which represents the core by a parallel L-R circuit, is used to interpret and present the magnetization characteristics and several figures of merit applicable to inductor materials are reviewed. The 100 kHz permeability thus derived decreases with increasing temperature for the Fe-based, nanocrystalline material, but increases roughly linearly with temperature for the two Co-based materials, as long as B(sub peak) is sufficiently low to avoid saturation effects. Due to the high permeabilities, rather low values of the 'quality factor' Q, from about 20 to below unity, were obtained over the frequency range of 50 kHz to 1 MHz (50 C, B(sub peak) = 0.1 T). Therefore these cores must be gapped in order to make up high Q or high current inductors. However, being rugged, low core loss materials with flat B-H loop characteristics, they may provide new solutions to specialty inductor applications.

  14. Effects of wear on structure-sensitive magnetic properties of ceramic ferrite in contact with magnetic tape

    NASA Technical Reports Server (NTRS)

    Miyoshi, K.; Buckley, D. H.; Tanaka, K.

    1985-01-01

    Wear experiments and electron microscopy and diffraction studies were conducted to examine the wear and deformed layers in single-crystal Mn-Zn (ceramic) ferrite magnetic head material in contact with magnetic tape and the effects of that contact on magnetic properties. The crystalline state of the single-crystal magnetic head was changed drastically during the sliding process. A nearly amorphous structure was produced on its wear surface. Deformation in the surficial layer of the magnetic head was a critical factor in readback signal loss above 2.5 dB. The signal output level was reduced as applied normal load was increased. Considerable plastic flow occurred on the magnetic tape surface with sliding, and the signal loss due to the tape wear was approximately 1 dB.

  15. Micrometric periodic assembly of magnetotactic bacteria and magnetic nanoparticles using audio tapes

    NASA Astrophysics Data System (ADS)

    Godoy, M.; Moreno, A. J.; Jorge, G. A.; Ferrari, H. J.; Antonel, P. S.; Mietta, J. L.; Ruiz, M.; Negri, R. M.; Pettinari, M. J.; Bekeris, V.

    2012-02-01

    We report micrometric periodic assembly of live and dead magnetotactic bacteria, Magnetospirillum magneticum AMB-1, which synthesize chains of magnetic nanoparticles inside their bodies, and of superparamagnetic Fe3O4 and ferromagnetic CoFe2O4 nanoparticles in aqueous suspensions using periodically magnetized audio tapes. The distribution of the stray magnetic field at the surface of the tapes was determined analytically and experimentally by magneto-optic imaging. Calculations showed that the magnetic field close to the tape surface was of the order of 100 mT, and the magnetic field gradient was larger than 1 T mm-1. Drops of aqueous solutions were deposited on the tapes, and bacteria and particles were trapped at locations where magnetic energy is minimized, as observed using conventional optical microscopy. Suspensions of M. magneticum AMB-1 treated with formaldehyde and kanamycin were studied, and patterns of trapped dead bacteria indicated that magnetic forces dominate over self-propelling forces in these experiments, in accordance with calculated values. The behavior of the different types of samples is discussed.

  16. 26 CFR 1.9101-1 - Permission to submit information required by certain returns and statements on magnetic tape.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... satisfied by submitting the information required by such form on magnetic tape or by other media, provided... submitting the information required by such form on magnetic tape or other approved media, provided that the prior consent of the Commissioner of Social Security (or other authorized officer or employee...

  17. 26 CFR 1.9101-1 - Permission to submit information required by certain returns and statements on magnetic tape.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... satisfied by submitting the information required by such form on magnetic tape or by other media, provided... submitting the information required by such form on magnetic tape or other approved media, provided that the prior consent of the Commissioner of Social Security (or other authorized officer or employee...

  18. 26 CFR 1.9101-1 - Permission to submit information required by certain returns and statements on magnetic tape.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... satisfied by submitting the information required by such form on magnetic tape or by other media, provided... submitting the information required by such form on magnetic tape or other approved media, provided that the prior consent of the Commissioner of Social Security (or other authorized officer or employee...

  19. 26 CFR 1.9101-1 - Permission to submit information required by certain returns and statements on magnetic tape.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... satisfied by submitting the information required by such form on magnetic tape or by other media, provided... submitting the information required by such form on magnetic tape or other approved media, provided that the prior consent of the Commissioner of Social Security (or other authorized officer or employee...

  20. 26 CFR 1.9101-1 - Permission to submit information required by certain returns and statements on magnetic tape.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... submitting the information required by such form on magnetic tape or by other media, provided that the prior... required by such form on magnetic tape or other approved media, provided that the prior consent of the Commissioner of Social Security (or other authorized officer or employee thereof) has been obtained....

  1. Goddard Space Flight Center specification for Helical-Scan 8-millimeter (mm) magnetic digital data tape cartridge

    NASA Technical Reports Server (NTRS)

    Perry, Jimmy L.

    1992-01-01

    The same kind of standard and controls are established that are currently in use for the procurement of new analog, digital, and IBM/IBM compatible 3480 tape cartridges, and 1 in wide channel video magnetic tapes. The Magnetic Tape Certification Facility (MTCF) maintains a Qualified Products List (QPL) for the procurement of new magnetic media and uses the following specifications for the QPL and Acceptance Tests: (1) NASA TM-79724 is used for the QPL and Acceptance Testing of new analog magnetic tapes; (2) NASA TM-80599 is used for the QPL and Acceptance Testing of new digital magnetic tapes; (3) NASA TM-100702 is used for the QPL and Acceptance Testing of new IBM/IBM compatible 3840 magnetic tape cartridges; and (4) NASA TM-100712 is used for the QPL and Acceptance Testing of new 1 in wide channel video magnetic tapes. This document will be used for the QPL and Acceptance Testing of new Helical Scan 8 mm digital data tape cartridges.

  2. Wide Temperature Characteristics of Transverse Magnetically Annealed Amorphous Tapes for High Frequency Aerospace Magnetics

    NASA Technical Reports Server (NTRS)

    Niedra, Janis M.

    1999-01-01

    100 kHz core loss and magnetization properties of sample transverse magnetically annealed, cobalt-based amorphous and iron-based nanocrystalline tape wound magnetic cores are presented over the temperature range of -150 to 150 C, at selected values of B(sub peak). For B-fields not close to saturation, the core loss is not sensitive to temperature in this range and is as low as seen in the best MnZn power ferrites at their optimum temperatures. Frequency resolved characteristics are given over the range of 50 kHz to 1 MHz, at B(sub peak) = 0.1 T and 50 C only. A linear permeability model is used to interpret and present the magnetization characteristics and several figures of merit applicable to inductor materials arc reviewed. This linear modeling shows that, due to their high permeabilities, these cores must he gapped in order to make up high Q or high current inductors. However, they should serve well, as is, for high frequency, anti ratcheting transformer applications.

  3. The effect of stabilizer on the trapped field of stacks of superconducting tape magnetized by a pulsed field

    NASA Astrophysics Data System (ADS)

    Page, A. G.; Patel, A.; Baskys, A.; Hopkins, S. C.; Kalitka, V.; Molodyk, A.; Glowacki, B. A.

    2015-08-01

    Stacks of high temperature superconducting tape, magnetized using pulsed fields, provide a new type of permanent magnet using superconductors. To optimize the trapped field in such stacks, the role of stabilization layers was investigated by pulse magnetizing a 12 mm square stack of 15 tape layers over a temperature range of 15-77 K. The stacks consisted of commercial tape with a silver stabilizer of 1-3 μm or tape with an additional 20 μm layer of copper on top of 1 μm of silver. It was found that the trapped field and flux are relatively insensitive to the stabilizer thickness, and 1 μm of silver only, led to the highest trapped field. An FEM model was also developed for a stack that considered for the first time both the actual thickness of metallic and superconducting layers, to investigate the effect of heating and heat transfer when a stack of tapes is magnetized.

  4. Wide Temperature Core Loss Characteristics of Transverse Magnetically Annealed Amorphous Tapes for High Frequency Aerospace Magnetics

    NASA Technical Reports Server (NTRS)

    Niedra, Janis M.; Schwarze, Gene E.

    1999-01-01

    100 kHz core loss properties of sample transverse magnetically annealed, cobalt-based amorphous and iron-based nanocrystalline tape wound magnetic cores are presented over the temperature range of -150 C to 150 C, at selected values of B(sub peak). For B-fields not close to saturation, the core loss is not sensitive to temperature in this range and is as low as seen in the best MnZn power ferrites at their optimum temperatures. Frequency resolved characteristics are given over the range of 50 kHz to 1 MHz, but at B(sub peak) = 0.1 T and 50 C only. For example, the 100 kHz specific core loss ranged from 50 - 70 mW/cubic cm for the 3 materials, when measured at 0.1 T and 50 C. This very low high frequency core loss, together with near zero saturation magnetostriction and insensitivity to rough handling, makes these amorphous ribbons strong candidates for power magnetics applications in wide temperature aerospace environments.

  5. Compilation of fatigue, fatigue-crack propagation, and fracture data for 2024 and 7075 aluminum, Ti-6Al-4V titanium, and 300M steel. Volume 1: Description of data and data storage on magnetic tape. Volume 2: Data tape (7-track magnetic tape)

    NASA Technical Reports Server (NTRS)

    Rice, R. C.; Reynolds, J. L.

    1976-01-01

    Fatigue, fatigue-crack-propagation, and fracture data compiled and stored on magnetic tape are documented. Data for 202 and 7075 aluminum alloys, Ti-6Al-4V titanium alloy, and 300M steel are included in the compilation. Approximately 4,500 fatigue, 6,500 fatigue-crack-propagation, and 1,500 fracture data points are stored on magnetic tape. Descriptions of the data, an index to the data on the magnetic tape, information on data storage format on the tape, a listing of all data source references, and abstracts of other pertinent test information from each data source reference are included.

  6. The standards process: Technical committee X3B5 digital magnetic tape

    NASA Technical Reports Server (NTRS)

    Cheatham, Sam

    1993-01-01

    The definition of X3B5, where it fits in the national and international standards development process, and how it interfaces and influences the world community of standards developers are provided. Details concerning the focus of the committee, how it operates, and what the group sees as the future trends in the area of interchange standards utilizing the multifaceted, ubiquitous magnetic tape are presented.

  7. Friction and morphology of magnetic tapes in sliding contact with nickel-zinc ferrite

    NASA Technical Reports Server (NTRS)

    Miyoshi, K.; Buckley, D. H.; Bhushan, B.

    1984-01-01

    Friction and morphological studies were conducted with magnetic tapes containing a Ni-Zn ferrite hemispherical pin in laboratory air at a relative humidity of 40 percent and at 23 C. The results indicate that the binder plays a significant role in the friction properties, morphology, and microstructure of the tape. Comparisons were made with four binders: nitrocellulose; poly (vinyledene) chloride; cellulose acetate; and hydroxyl-terminated, low molecular weight polyester added to the base polymer, polyester-polyurethane. The coefficient of friction was lowest for the tape with the nitrocellulose binder and increased in the order hydroxylterminated, low molecular weight polyester resin; poly (vinyledene) chloride; and cellulose acetate. The degree of enclosure of the oxide particles by the binder was highest for hydroxyl-terminated, low molecular weight polyester and decreased in the order cellulose acetate, poly (vinyledene) chloride, and nitrocellulose. The nature of deformation of the tape was a factor in controlling friction. The coefficient of friction under elastic contact conditions was considerably lower than under conditions that produced plastic contacts.

  8. Insert Coil Test for HEP High Field Magnets Using YBCO Coated Conductor Tapes

    SciTech Connect

    Lombardo, V.; Barzi, E.; Turrioni, D.; Zlobin, A.V.; /Fermilab

    2011-06-15

    The final beam cooling stages of a Muon Collider may require DC solenoid magnets with magnetic fields of 30-50 T. In this paper we present progress in insert coil development using commercially available YBa{sub 2}Cu{sub 3}O{sub 7-{delta}} Coated Conductor. Technological aspects covered in the development, including coil geometry, insulation, manufacturing process and testing are summarized and discussed. Test results of double pancake coils operated in liquid nitrogen and liquid helium are presented and compared with the performance of YBa{sub 2}Cu{sub 3}O{sub 7-{delta}} tape short samples.

  9. A high temperature superconductor tape RF receiver coil for a low field magnetic resonance imaging system

    NASA Astrophysics Data System (ADS)

    Cheng, M. C.; Yan, B. P.; Lee, K. H.; Ma, Q. Y.; Yang, E. S.

    2005-08-01

    High temperature superconductor (HTS) thin films have been applied in making a low loss RF receiver coil for improving magnetic resonance imaging image quality. However, the application of these coils is severely limited by their limited field of view (FOV). Stringent fabrication environment requirements and high cost are further limitations. In this paper, we propose a simpler method for designing and fabricating HTS coils. Using industrial silver alloy sheathed Bi(2-x)PbxSr2Ca2Cu3O10 (Bi-2223) HTS tapes, a five-inch single-turn HTS solenoid coil has been developed, and human wrist images have been acquired with this coil. The HTS tape coil has demonstrated an enhanced FOV over a six-inch YBCO thin film surface coil at 77 K with comparable signal-to-noise ratio.

  10. Recent developments in processing HTS silver-clad Bi-2223 tapes, coils and test magnets

    SciTech Connect

    Haldar, P.; Hoehn, J.G. Jr.; Motowidlo, L.R.; Balachandran, U.; Iwasa, Y.; Yunus, M.

    1993-10-01

    Considerable progress has been made in fabricating Bi-2223 high temperature superconductor (HTS) wires and tapes with high critical current densities that are attractive for electric power and high-field magnet applications. Powder-in-tube processed silver-clad Bi-2223 short tape samples, small coils and test magnets have been fabricated and measured at liquid nitrogen (77K), pumped liquid nitrogen (64 K), liquid neon (27K) and liquid helium (4.2K) temperatures. Optimization of thermo-mechanical process parameters have yielded J{sub c}`s in the superconducting core > 4.0 {times} 10{sup 4} A/cm{sup 2} at 77K zero field and > 2.0 {times} 10{sup 5} A/cm{sup 2} at 4.2K, zero field. Long lengths (up to 70 m) of mono-core conductors were fabricated and tested to carry significant amounts of current (23 A, {approximately}15,000 A/cm{sup 2}) at liquid nitrogen temperature. Recent test magnets assembled from pancake wound coils were measured to generate magnetic fields as high as 2.6, 1.8 and 0.36 Tesla at 4.2K, 27K and 77K respectively. These results show promise towards practical utilization of HTS materials.

  11. Studies into the use of waterborne coating formulations for the preparation of magnetic tape (abstract)

    NASA Astrophysics Data System (ADS)

    Barrom, Stacy; Bray, Ashley; Cheng, Song; Elike, John; Fan, Hong; Lane, Alan M.; Nikles, David E.

    1994-05-01

    The objective of this research project is to replace the organic solvents used in modern tape manufacture with water, thereby eliminating the potential for solvent emissions. This has led to a search to identify tape components compatible with a waterborne coating process. The pigments were either cobalt-modified γ-Fe2O3 or barium ferrite, with the majority of the research focused on cobalt-modified γ-Fe2O3 formulations. A combination of sodium polyphosphate and Surfynol CT-136, a pigment grinding aid, were used as dispersing agents. The binders included commercial water-dispersed polyurethanes and a commercial ethylene-vinylchloride copolymer emulsion. A commercial waterborne melamine-formaldehyde was used as a cross-linking agent. Addition of the ethylene-vinylchloride copolymer to the polyurethane increased the tensile strength and Young's modulus of the unpigmented binder films. The melamine-formaldehyde cross-linker further enhanced the mechanical properties and increased the adhesion between the pigmented binder films and the polyester base film. In a 180° peel test, the adhesion easily exceeded the ITO specification for 8 mm helical scan magnetic tape.1 Rheological studies of the waterborne dispersions revealed that the viscosity was too low. Hydroxyethylcellulose, a water soluble polymer, was added as a thickener and this gave rise to a desirable thixotropic behavior in the dispersion. Waterborne dispersions were cast onto polyester base film, oriented in a 2000 G longitudinal magnetic field, and cured in a convection oven at 60 °C. Magnetic hysteresis loops showed a squareness of 0.875 and a switching field distribution of 0.324 for films containing cobalt-modified γ-Fe2O3.

  12. Striped tape arrays

    NASA Technical Reports Server (NTRS)

    Drapeau, Ann L.; Katz, Randy H.

    1992-01-01

    A growing number of applications require high capacity, high throughput tertiary storage systems. How data striping ideas apply to arrays of magnetic tape drives is investigated. Data striping increases throughput and reduces response time for large accesses to a storage system. Striped magnetic tape systems are particularly appealing because many inexpensive magnetic tape drives have low bandwidth; striping may offer dramatic performance improvements for these systems. There are several important issues in designing striped tape systems: the choice of tape drives and robots, whether to stripe within or between robots, and the choice of the best scheme for distributing data on cartridges. One of the most troublesome problems in striped tape arrays is the synchronization of transfers across tape drives. Another issue is how improved devices will affect the desirability of striping in the future. The results of simulations comparing the performance of striped tape systems to non-striped systems are presented.

  13. Magnetic Properties of the Stack of HTSC Tapes in a Wide Temperature Range

    NASA Astrophysics Data System (ADS)

    Rudnev, Igor; Abin, Dmitriy; Osipov, Maxim; Pokrovskiy, Sergey; Ermolaev, Yuriy; Mineev, Nikolay

    The trapped field strength of HTSC stacks were measured in the temperature range T=4-80 K and dc magnetic fields up to 8 Т. A single 12 mm by 12 mm square samples were cut from commercial (RE)BCO tape 12 mm wide and then stacked together. The number of layers in the stacks was varied from n=5 to n=250. Trapped field strength was measured by means of Hall probe which was placed directly on the stacks surface. The dependences of remnant field strength Brem on number of layers in the stacks at different temperature Brem (n) as well as on temperature dependences Brem (T) at various n were obtained. It was found that Brem (n) dependences have a nonlinear character with a tendency to saturation for n > 60. The maximum remnant (trapped) field was found to be more than 2.5 Т at T=4 К. The relaxation of trapped field was studied also and it was determined that the rate of relaxation processes tends to decrease with the increase in a number of tapes in the stack. The correlation between dependency Brem (n) and dependency of magnetic levitation force measured at T=77 K at zero field cooling were found.

  14. Critical currents of YBCO tapes and Bi-2212 wires at different temperatures and magnetic fields

    SciTech Connect

    Lombardo, V.; Barzi, e.; Turrioni, D.; Zlobin, A.V.; /Fermilab

    2010-08-01

    Design studies for the cooling channel of a Muon Collider call for straight and helical solenoids generating field well in excess of the critical fields of state of the art Low Temperature Superconductors (LTS) such as Nb{sub 3}Sn or NbTi. Therefore, High Temperature Superconductors (HTS) will need to be used for the manufacturing of all or certain sections of such magnets to be able to generate and withstand the field levels at the cryogenic temperatures required by the new machine. In this work, two major High Temperature Superconductors - Bi2212 round wires and YBCO coated conductor tapes - are investigated to understand how critical current density of such conductors scales as a function of external field and operating temperature. This is vital information to make conductor choices depending on the application and to proceed with the design of such magnets.

  15. Trapped fields up to 2 T in a 12 mm square stack of commercial superconducting tape using pulsed field magnetization

    NASA Astrophysics Data System (ADS)

    Patel, A.; Hopkins, S. C.; Glowacki, B. A.

    2013-03-01

    The ability of superconductors to sustain persistent currents has been well exploited with (RE)BCO superconducting bulks, which can be magnetized to form a compact source of high magnetic field. However, thin films can also sustain persistent currents, which can be utilized by stacking them in layers to create a type of composite bulk. Such a stack is capable of trapping higher fields than a bulk, as reported in this paper. 12 mm wide, 55 μm thick commercial (RE)BCO tape from Superpower Inc was cut into 12 mm by 12 mm squares, stacked together and magnetized at temperatures between 10 and 77.4 K using a sequence of pulsed magnetic fields. The results are compared to a commercial 14 mm diameter YBCO bulk, showing that the stack of tapes outperformed the bulk at temperatures below approximately 60 K. Particularly high trapped fields were achieved below 50 K, with a maximum of 2.0 T at 10 K measured 0.8 mm from the stack surface. The maximum trapped field possible for a stack of tapes increases significantly with decreasing temperature down to 10 K, rather than saturating at a higher temperature as in the case of a bulk, due to superior thermal stability. The Jc, thermal and mechanical properties of commercial (RE)BCO tapes give them great potential for use as trapped field magnets activated by pulsed magnetic fields.

  16. Evolution of a high-performance storage system based on magnetic tape instrumentation recorders

    NASA Astrophysics Data System (ADS)

    Peters, Bruce

    In order to provide transparent access to data in network computing environments, high performance storage systems are getting smarter as well as faster. Magnetic tape instrumentation recorders contain an increasing amount of intelligence in the form of software and firmware that manages the processes of capturing input signals and data, putting them on media and then reproducing or playing them back. Such intelligence makes them better recorders, ideally suited for applications requiring the high-speed capture and playback of large streams of signals or data. In order to make recorders better storage systems, intelligence is also being added to provide appropriate computer and network interfaces along with services that enable them to interoperate with host computers or network client and server entities. Thus, recorders are evolving into high-performance storage systems that become an integral part of a shared information system. Data tape has embarked on a program with the Caltech sponsored Concurrent Supercomputer Consortium to develop a smart mass storage system. Working within the framework of the emerging IEEE Mass Storage System Reference Model, a high-performance storage system that works with the STX File Server to provide storage services for the Intel Touchstone Delta Supercomputer is being built. Our objective is to provide the required high storage capacity and transfer rate to support grand challenge applications, such as global climate modeling.

  17. Evolution of a high-performance storage system based on magnetic tape instrumentation recorders

    NASA Technical Reports Server (NTRS)

    Peters, Bruce

    1993-01-01

    In order to provide transparent access to data in network computing environments, high performance storage systems are getting smarter as well as faster. Magnetic tape instrumentation recorders contain an increasing amount of intelligence in the form of software and firmware that manages the processes of capturing input signals and data, putting them on media and then reproducing or playing them back. Such intelligence makes them better recorders, ideally suited for applications requiring the high-speed capture and playback of large streams of signals or data. In order to make recorders better storage systems, intelligence is also being added to provide appropriate computer and network interfaces along with services that enable them to interoperate with host computers or network client and server entities. Thus, recorders are evolving into high-performance storage systems that become an integral part of a shared information system. Data tape has embarked on a program with the Caltech sponsored Concurrent Supercomputer Consortium to develop a smart mass storage system. Working within the framework of the emerging IEEE Mass Storage System Reference Model, a high-performance storage system that works with the STX File Server to provide storage services for the Intel Touchstone Delta Supercomputer is being built. Our objective is to provide the required high storage capacity and transfer rate to support grand challenge applications, such as global climate modeling.

  18. Effects of Patellar Taping on Brain Activity During Knee Joint Proprioception Tests Using Functional Magnetic Resonance Imaging

    PubMed Central

    McKie, Shane; Richardson, Paul; Oldham, Jacqueline A.

    2012-01-01

    Background Patellar taping is a common treatment modality for physical therapists managing patellofemoral pain. However, the mechanisms of action remain unclear, with much debate as to whether its efficacy is due to a change in patellar alignment or an alteration in sensory input. Objective The purpose of this study was to investigate the sensory input hypothesis using functional magnetic resonance imaging when taping was applied to the knee joint during a proprioception task. Design This was an observational study with patellar taping intervention. Methods Eight male volunteers who were healthy and right-leg dominant participated in a motor block design study. Each participant performed 2 right knee extension repetitive movement tasks: one simple and one proprioceptive. These tasks were performed with and without patellar taping and were auditorally paced for 400 seconds at 72 beats/min (1.2 Hz). Results The proprioception task without patellar taping caused a positive blood oxygenation level–dependant (BOLD) response bilaterally in the medial supplementary motor area, the cingulate motor area, the basal ganglion, and the thalamus and medial primary sensory motor cortex. For the proprioception task with patellar taping, there was a decreased BOLD response in these regions. In the lateral primary sensory cortex, there was a negative BOLD response with less activity for the proprioception task with taping. Limitations This study may have been limited by the small sample size, a possible learning effect due to a nonrandom order of tasks, and use of a single-joint knee extension task. Conclusions This study demonstrated that patellar taping modulates brain activity in several areas of the brain during a proprioception knee movement task. PMID:22282771

  19. PHOTOELECTRIC CONTROL FOR TAPE POSITIONING

    DOEpatents

    Woody, J.W. Jr.

    1961-07-25

    A control system is described for producing control impulses which may be used to start, stop, and position a magnetic tape with respect to a transducer, and to locate discrete areas on the tape. Means are provided for positive identification of data blocks, exact positioning of the tape under the magnetic head, drive in either direction, accurate skip-over of imperfect regions of the tape, stopping the tape if equipment malfunction results in a failure to detect the block-identifying signals, and starting and stopping those parts of the tape between of the tape drive clutches.

  20. VLBA: Formatter to Tape

    NASA Astrophysics Data System (ADS)

    Rogers, A. E. E. R.

    Introduction; Why Magnetic Tape?; VLBI Recording Systems; The VLBA Data Format; Longitudinal Format; Transverse Track Format; Data and Non-Data Replacement; Track Width and Track Structure; The VLBA Formatter; Switch Board; Header Control Board; Transport Driver Board; Timing and Control Board; DataBuffer Board; Analysis Board; Magnetic Recording Fundamentals; Recording Losses; Wavelength Response; Head-to-Tape Contact and Tribology; The VLBA Recorder; The Tape Transport; The Headstack; The Headstack Positioner; Control Electronics; Signal Electronics and Eye Pattern; Characteristics and Limitations; Error Rate Versus Bit Density; Tape Thickness Interchange; Head Flying; Overwrite; Tracking Errors; Headlife and Humidity; Thin Tape and Edge Damage by Frictional Heating; Tape Reel and Shipping Canister; Future VLBI Recording Systems; Expansion Paths for the VLBA Formatter; Recorder Improvements; Thinner Tape; Higher Data Rates; Next Generation of Heads; Mark IV; Summary and Conclusions

  1. Combined magnetic screen made of Bi-2223 bulk cylinder and YBCO tape rings—Modeling and experiments

    NASA Astrophysics Data System (ADS)

    Tomków, Ł.; Ciszek, M.; Chorowski, M.

    2015-01-01

    Recent advances in the measurements with sensitive magnetic field sensors made the issue of magnetic shielding important. The application of high temperature superconductors allows to obtain full shielding in zero field cooling conditions for DC and low frequency magnetic fields by the means of the Meissner effect. However, currently used conventional bulk magnetic shields maintain full shielding only in low magnetic fields—up to approximately 10 mT. In this paper, it is proposed to apply an additional screen made of a coated superconducting tape in order to increase the magnetic field interval of full shielding region. Computer model of such set of screens was created in Matlab and validated experimentally. Improvement of shielding quality was observed experimentally and calculated with the model.

  2. Kinematics of Tape Recording.

    ERIC Educational Resources Information Center

    Coleman, J. J.

    1982-01-01

    Describes mathematics of the nonliner relationships between a constant-speed, capstan-driven magnetic tape transport mechanism and a constant-angular-velocity take-up reel. The relationship, derived from the sum of a partial, serves in recognition of a finite tape. Thickness can serve as an example of rotational kinematics. (Author/SK)

  3. Observation of self-magnetic field relaxations in Bi2223 and Y123 HTS tapes after over-current pulse and DC current operation

    NASA Astrophysics Data System (ADS)

    Tallouli, M.; Sun, J.; Chikumoto, N.; Otabe, E. S.; Shyshkin, O.; Charfi-Kaddour, S.; Yamaguchi, S.

    2016-07-01

    The development of power transmission lines based on long-length HTS tapes requires the production of high quality tapes. Due to fault conditions, technical mistakes and human errors during the operation of a DC power transmission line, an over-current pulse, several times larger than the rated current, could occur. To study the effect of such over-current pulses on the transport current density distribution in the HTS tapes, we simulated two start-up scenarios for one BSCCO and two YBCO tapes. The first start-up scenario is an initial over-current pulse during which the transport current was turned on rapidly, rising to 900 A during the first milliseconds, then reduced to a 100 A DC current. The second start-up scenario is normal operation, and involved increasing the transport current slowly from 0 A to 100 A at a rate of 1 A/s. For both scenarios, we then measured the vertical component of the self-magnetic field by means of a Hall probe above the tape, and afterward, by solving a linear equation of the inverse problem we obtain the current density profiles. We observe a change of the self-magnetic field above the edge of the BSCCO and YBCO tapes during 30 min after the 5 ms of over-current pulse and during the normal operation. The current density profiles are peaked in the centre for over-current pulse, and more peaked around the edge of the HTS tape for normal operation, which means that the limited time over-current pulse changes the current density profiles of the HTS tapes. We observe also a loop of current for YBCO tapes and we show the role of the HTS tape stabilizer.

  4. Experimental measurement of characteristic Ic (ɛ, θ, B) response in GdBa2Cu3Oδ coated conductor tapes under low magnetic field at 77 K

    NASA Astrophysics Data System (ADS)

    Shin, Hyung-Seop; Dedicatoria, Marlon J.; Gorospe, Alking; Lee, Sang-Heon

    2015-03-01

    The continued development in the design technology of practical superconducting devices adopting high temperature superconductors tapes has led to a deeper understanding of their electromechanical behaviors. Rare-earth-barium-copper-oxide coated conductor (CC) tapes exhibit anisotropy of transport property (Ic) under magnetic field and its intrinsic strain effect is much significant depending on the orientation to the tape surface and the magnetic field intensity applied. Different experimental systems have already been developed to measure the relation of Ic with mechanical strain ɛ, magnetic field intensity B, and its angle of orientation, θ. However, few systems and instruments can measure these relationships simultaneously; either Ic-B-θ or Ic-ɛ-B is usually measured. In this study, a device which can measure these influences simultaneously based on a pair of permanent magnet systems was constructed and the characteristic responses of critical current Ic with strain, magnetic field, and its orientation with respect to the CC tape surface were investigated. The angular dependence of Ic with strain at 77 K in reactive co-evaporation by deposition and reaction GdBCO CC tapes has been measured using the permanent magnet system. The orientation angle of magnetic field with respect to the tape's surface was varied by rotating the rig fixture that holds a pair of permanent magnets. The strain sensitivity of Ic at different angles under low magnetic field was evaluated. As a result, a characteristic surface Ic (ɛ, θ, B) has been constructed as the characteristic response of Ic with strain and varying orientation under magnetic field.

  5. Humidity effects on adhesion of nickel-zinc ferrite in elastic contact with magnetic tape and itself

    NASA Technical Reports Server (NTRS)

    Miyoshi, K.; Buckley, D. H.; Kusaka, T.; Maeda, C.

    1985-01-01

    The effects of humidity on the adhesion of Ni-Zn ferrite and magnetic tape in elastic contact with a Ni-Zn ferrite hemispherical pin in moist nitrogen were studied. Adhesion was independent of normal load in dry, humid, and saturated nitrogen. Ferrites adhere to ferrites in a saturated atmosphere primarily from the surface tension effects of a thin film of water adsorbed on the ferrite surfaces. The surface tension of the water film calculated from the adhesion results was 48 times 0.00001 to 56 times 0.00001 N/cm; the accepted value for water is 72.7 x 0.00001 N/cm. The adhesion of ferrite-ferrite contacts increased gradually with increases in relative humidity to 80 percent, but rose rapidly above 80 percent. The adhesion at saturation was 30 times or more greater than that below 80 percent relative humidity. Although the adhesion of magnetic tape - ferrite contacts remained low below 40 percent relative humidity and the effect of humidity was small, the adhesion increased considerably with increasing relative humidity above 40 percent. The changes in adhesion of elastic contacts were reversible on humidifying and dehumidifying.

  6. Progress in development of tapes and magnets made from Bi-2223 superconductors

    NASA Technical Reports Server (NTRS)

    Balachandran, U.; Iyer, A. N.; Haldar, P.; Hoehn, J. G., Jr.; Motowidlo, L. R.

    1995-01-01

    Long lengths of (Bi,Pb)2Sr2Ca2Cu3O(x) tapes made by powder-in-tube processing have been wound into coils. Performance of the coils has been measured at temperatures of 4.2 to 77 K, and microstructures have been examined by x-ray diffraction and electron microscopy and then related to superconducting properties. A summary of recent results and an overview of future goals are presented.

  7. Niobium-germanium superconducting tapes for high-field magnet applications

    NASA Technical Reports Server (NTRS)

    Braginski, A. I.; Roland, G. W.; Daniel, M. R.; Woolam, J. A.

    1977-01-01

    A process of fabricating superconducting Nb3Ge tapes by chemical vapor deposition (CVD) has been developed and tapes up to 10 meters long fabricated. The typical properties achieved were: critical temperature T sub c = 20 K, upper critical field H sub c2 = 29 tesla at 4.2 K, and J sub c = 3 to 4 x 10 to the 8th power A m(-2) at 4.2 K, 18 tesla. The relative depression of T sub c and H sub c2 compared with the best thin film samples sputtered on sapphire was due to the presence of Nb5Ge3 second-phase particles used as flux pinning centers and to strains induced by thermal mixmatch with Hastelloy B tape substrates. A peculiar field dependence of flux pinning force that was observed in both CVD and sputtered Nb3Ge indicated a premature pin-breaking mechanism or a phase inhomogeneity. Directions of further optimization work were defined.

  8. Magnetic Tape Storage and Handling: A Guide for Libraries and Archives.

    ERIC Educational Resources Information Center

    Van Bogart, John W. C.

    This document provides a guide on how to properly store and care for magnetic media to maximize their life expectancies. An introduction compares magnetic media to paper and film and outlines the scope of the report. The second section discusses things that can go wrong with magnetic media. Binder degradation, magnetic particle instabilities,…

  9. Variation of critical current and n-value of 2G HTS tapes in external magnetic fields of different orientation

    NASA Astrophysics Data System (ADS)

    Sychugov, V. V.; Degtyarenko, P. N.; Ovcharov, A. V.; Shavkin, S. V.; Kruglov, V. S.; Vasiliev, A. L.; Volkov, P. V.; Chesnokov, Yu M.

    2016-09-01

    The in-field orientation dependence of critical current and n-value in second generation high temperature superconductive tapes was investigated. The samples were manufactured by Metalorganic Chemical Vapour Deposition method with BaZrO3 inclusions (SuperPower Inc.) and Pulsed Laser Deposition method (Bruker HTS). For samples of each kind of fabrication techniques we observed higher critical current value in the case of external magnetic field aligned along (or nearby) c-axis direction in comparison with one aligned along ab-plane. We analysed possible reasons for this effect. Angular dependences of the critical current and n-value were investigated. The microstructure images of superconductive layer of studied samples show tilt of BaZrO3 nanorods in MOCVD sample and high density of structural defects for PLD sample.

  10. Set processing in a network environment. [data bases and magnetic disks and tapes

    NASA Technical Reports Server (NTRS)

    Hardgrave, W. T.

    1975-01-01

    A combination of a local network, a mass storage system, and an autonomous set processor serving as a data/storage management machine is described. Its characteristics include: content-accessible data bases usable from all connected devices; efficient storage/access of large data bases; simple and direct programming with data manipulation and storage management handled by the set processor; simple data base design and entry from source representation to set processor representation with no predefinition necessary; capability available for user sort/order specification; significant reduction in tape/disk pack storage and mounts; flexible environment that allows upgrading hardware/software configuration without causing major interruptions in service; minimal traffic on data communications network; and improved central memory usage on large processors.

  11. FGGE/SBUV tape specification and shipping letter description

    NASA Technical Reports Server (NTRS)

    Han, D.; Lo, H.

    1983-01-01

    The FGGE/SBUV Level 2C data set consists of 12 9-track data tapes, each of which contains total ozone and ozone profile data for one calendar month grouped in files containing the data in a 6 hour synoptic time block. The data flow and quality checks in the production of this data set are described as well as the format of the data tapes and the accompanying shipping documents.

  12. A study of the magnetic field distribution in an Ag-sheathed Bi2223 tape using scanning Hall sensor and magneto-optical techniques

    NASA Astrophysics Data System (ADS)

    Kawano, K.; Abell, J. S.; Ohtake, A.; Oota, A.

    2000-09-01

    Using both magneto-optical (MO) and scanning Hall sensor techniques, magnetic field distributions have been observed in a superconducting Ag-sheathed Bi2223 monofilamentary tape in the presence of an external magnetic field. Application of the inversion scheme to the MO contrast has allowed the two-dimensional current distribution to be determined. The Hall sensor measurements indicate that the current distribution in the core depends on the applied external field, and the current flows mainly at the edge of the core in a high external field. The magnetic line profiles across the width of the tape have been analysed by a numerical calculation by modelling the current loops based on the two-dimensional current distribution from the MO image. The analysis shows that an increase in the external field limits and narrows the current flow region from the whole of the core to the edge.

  13. Performance of pancake coils of parallel co-wound Ag/BSCCO tape conductors in static and ramped magnetic fields

    SciTech Connect

    Schwenterly, S.W.; Lue, J.W.; Lubell, M.S.; Walker, M.S.; Hazelton, D.W.; Haldar, P.; Rice, J.A.; Hoehn, J.G. Jr.; Motowidlo, L.R.

    1994-12-31

    Critical Currents are reported for several Ag/BSCCO single-pancake coils in static magnetic fields ranging from 0 to 5 T and temperatures from 4.2 K to 105 K. The sample coils were co-wound of one to six tape conductors in parallel. Since the closed loops formed in such an arrangement could lead to eddy current heating or instability in changing fields, one of the coils was also tested in helium gas, in fields ramped at rates of up to 1.5 T/s. For these quasi-adiabatic tests, at each temperature the transport current was set just below the critical value for a preset static field of 3.3 or 4.9 T. The field was then rapidly ramped down to zero, held for 20 sec, and then ramped back up to the original value. The maximum observed temperature transient of about 1.7 K occurred at 9 K, for a field change of 4.75 T. The temperature transients became negligible when the sample was immersed in liquid helium. Above 30 K, the transients were below 1 K. These results give confidence that parallel co-wound HTSC coils are stable in a rapidly-ramped magnetic field, without undue eddy current heating.

  14. Industrial Tape

    NASA Technical Reports Server (NTRS)

    1986-01-01

    Scotch Brand Tape 364 was developed for NASA by 3M Company to protect electrical instrumentation coils and fluid lines from rocket launch blast conditions. It is an aluminized glass cloth tape which can withstand very high temperatures, is easily applied to compound surfaces, has excellent solar energy reflectance, and does not present an electrostatic hazard. It has potential automotive, transportation, and building construction applications.

  15. Tape edge study in a linear tape drive with single-flanged guides

    NASA Astrophysics Data System (ADS)

    Goldade, Anton V.; Bhushan, Bharat

    2004-05-01

    Improved tape guiding and tape dimensional stability are essential for magnetic tape linear recoding formats to take advantage of vastly increased track density and thereby achieve higher storage capacities. Tape guiding is dependent on numerous parameters, such as type of the guides and tape path geometry, quality of virgin tape edge, drive operating parameters (e.g., tape speed and tape tension), mechanical properties of the tape, and tape geometry (e.g., cupping and curvature). The objective of the present study is to evaluate guiding and tribological performance of single-flanged guides with porous air bearings in a linear tape drive. A comparison of guiding performance of the dual flanged stationary guides and single-flanged guides with porous air bearings is performed. The effect of tape path geometry, drive operating conditions (speed and tension) and tape edge quality of factory-slit tapes on tape guiding are evaluated during short-term tests. A lateral force measurement technique is used to measure the force exerted by the tape edge on the guide flange. A technique for the lateral tape motion measurement is used to study the effect of continuous sliding on tape guiding. Wear tests up to 5000 cycles are conducted and coefficient of friction and lateral tape motion are monitored to study the effect of drive operating conditions (speed and tension), edge quality of factory-slit tapes and tape thickness on tape guiding. Optical microscopy, atomic force microscopy and scanning electron microscopy are employed to study and quantify the quality of tape edge.

  16. A kinetic study of hydrolysis of polyester elastomer in magnetic tape

    NASA Technical Reports Server (NTRS)

    Yamamoto, K.; Watanabe, H.

    1994-01-01

    A useful method for kinetic study of the hydrolysis of polyester elastomer is established which uses the number-average molecular weight. The reasonableness of this method is confirmed and the effect of magnetic particles on hydrolysis is considered.

  17. Center for Information Services, Phase II: Detailed System Design and Programming, Part 2 - A Study of Customized Literature Searching Using "CA Condensates" and "CT" Magnetic Tape Data Bases, Phase IIA Final Report.

    ERIC Educational Resources Information Center

    Forrest, Kathryn S.

    An experimental program using two magnetic tape data bases from Chemical Abstracting Service ("CT," and "CA Condensates") at the University of California at Riverside (UCR) is reported. Cost studies are based entirely upon the University's ability to purchase the tapes and the Computing Center's interest in underwriting part of the project.…

  18. Factors limiting the sensitivity and dynamic range of a seismic system employing analog magnetic tape recording and a seismic amplifier with adjustable gain settings and several output levels

    USGS Publications Warehouse

    Eaton, Jerry P.; Van Schaack, John R.

    1977-01-01

    In the course of modernizing the low-speed-tape-recorder portable seismic systems and considering the possibilities for the design of a cassette-tape-recorder seismic refraction system, the factors that limit the sensitivity and dynamic range of such systems have been reviewed. These factors will first be stated briefly, and then their influence on systems such as the new 5-day-tape seismic system will be examined in more detail. To fix ideas, we shall assume that the system consists of the following elements: 1. A seismic sensor: usually a moving coil inertial seismometer with a period of about 1 second, a coil resistance of about 5000 ohms, and an effective motor constant of 1.0 V/cm/sec (across a 10K load terminating the seismometer sensitivity-and-damping-adjustment resistive network). 2. A seismic amplifier/voltage controlled oscillator unit made up of the following components: a) A fixed gain preamplifier with an input resistance of 10K and an internal noise level of 0.5 muVpp referred to the preamp input (0.1 Hz <= freq. <= 30 hz). b) An adjustable gain (0 to 42 db in 6 db steps) intermediate amplifier c) One or more fixed gain output amplifiers. d) Two sections of 6 db/octave bandpass filter serving to couple the 3 amplifier stages together. e) Voltage controlled oscillators for each output amplifier to produce modulated FM carriers for recording on separate tape tracks or modulated FM subcarriers for subsequent multiplexing and direct recording on tape in the California Network format. 3. An analog magnetic tape recorder: e.g. the PI 5100 (15/80 ips recording in the FM mode or in the direct mode with the 'broad-band' variant-of the Cal Net multiplex system, or 15/16 ips recording in the direct mode with the standard Cal Net multiplex system), or the Sony TC-126 cassette recorder operating in the direct record mode with the standard Cal Net multiplex system. 4. Appropriate magnetic tape playback equipment: e.g., the Bell and Howell 3700-B for the PI-5100 or

  19. Processing of DMSP magnetic data: Handbook of programs, tapes, and datasets

    NASA Technical Reports Server (NTRS)

    Langel, R. A.; Sabaka, T. J.; Ridgway, J. R.

    1990-01-01

    The DMSP F-7 satellite was an operational Air Force meteorological satellite which carried a magnetometer for geophysical measurements. The magnetometer was located within the body of the spacecraft in the presence of large spacecraft fields. In addition to stray magnetic fields, the data have inherent position and time inaccuracies. Algorithms were developed to identify and remove time varying magnetic field noise from the data. These algorithms are embodied in an automated procedure which fits a smooth curve through the data and then identifies outliers and which filters the predominant Fourier component of noise from the data. Techniques developed for Magsat were then modified and used to attempt determination of the spacecraft fields, of any rotation between the magnetometer axes and the spacecraft axes, and of any scale changes within the magnetometer itself. Software setup and usage are documented and program listings are included in the Appendix. The initial and resulting data are archived on magnetic cartridge and the formats are documented.

  20. ICI optical data storage tape

    NASA Technical Reports Server (NTRS)

    Mclean, Robert A.; Duffy, Joseph F.

    1991-01-01

    Optical data storage tape is now a commercial reality. The world's first successful development of a digital optical tape system is complete. This is based on the Creo 1003 optical tape recorder with ICI 1012 write-once optical tape media. Several other optical tape drive development programs are underway, including one using the IBM 3480 style cartridge at LaserTape Systems. In order to understand the significance and potential of this step change in recording technology, it is useful to review the historical progress of optical storage. This has been slow to encroach on magnetic storage, and has not made any serious dent on the world's mountains of paper and microfilm. Some of the reasons for this are the long time needed for applications developers, systems integrators, and end users to take advantage of the potential storage capacity; access time and data transfer rate have traditionally been too slow for high-performance applications; and optical disk media has been expensive compared with magnetic tape. ICI's strategy in response to these concerns was to concentrate its efforts on flexible optical media; in particular optical tape. The manufacturing achievements, media characteristics, and media lifetime of optical media are discussed.

  1. Investigation of current transport normal and parallel to the tape plane in BSCCO/Ag tapes

    SciTech Connect

    Maley, M.P.; Cho, J.H.; Willis, J.O.; Bulaevskii, L.N.

    1995-07-01

    We have performed transport, resistivity and critical current measurements on Bi-2223/Ag and Bi-2212/Ag tapes with current directions both parallel and perpendicular to the tape plane in magnetic fields up to 7 T and 50tape normal (nominal c-axis in a textured tape) is metallic, scales with the inplane resistivity at all fields and is dramatically reduced from single crystal c-axis values. Similarly, the critical current along the tape normal exhibits magnetic field and field orientation dependences similar to those for current flow along the tape plane. These results indicate that current flow along CuO{sub 2} planes dominates current transport even along the tape normal in highly textured tapes.

  2. Experimental measurement of characteristic I(c) (ε, θ, B) response in GdBa2Cu3Oδ coated conductor tapes under low magnetic field at 77 K.

    PubMed

    Shin, Hyung-Seop; Dedicatoria, Marlon J; Gorospe, Alking; Lee, Sang-Heon

    2015-03-01

    The continued development in the design technology of practical superconducting devices adopting high temperature superconductors tapes has led to a deeper understanding of their electromechanical behaviors. Rare-earth-barium-copper-oxide coated conductor (CC) tapes exhibit anisotropy of transport property (Ic) under magnetic field and its intrinsic strain effect is much significant depending on the orientation to the tape surface and the magnetic field intensity applied. Different experimental systems have already been developed to measure the relation of Ic with mechanical strain ε, magnetic field intensity B, and its angle of orientation, θ. However, few systems and instruments can measure these relationships simultaneously; either Ic-B-θ or Ic-ε-B is usually measured. In this study, a device which can measure these influences simultaneously based on a pair of permanent magnet systems was constructed and the characteristic responses of critical current Ic with strain, magnetic field, and its orientation with respect to the CC tape surface were investigated. The angular dependence of Ic with strain at 77 K in reactive co-evaporation by deposition and reaction GdBCO CC tapes has been measured using the permanent magnet system. The orientation angle of magnetic field with respect to the tape's surface was varied by rotating the rig fixture that holds a pair of permanent magnets. The strain sensitivity of Ic at different angles under low magnetic field was evaluated. As a result, a characteristic surface Ic (ε, θ, B) has been constructed as the characteristic response of Ic with strain and varying orientation under magnetic field. PMID:25832245

  3. Experimental measurement of characteristic I(c) (ε, θ, B) response in GdBa2Cu3Oδ coated conductor tapes under low magnetic field at 77 K.

    PubMed

    Shin, Hyung-Seop; Dedicatoria, Marlon J; Gorospe, Alking; Lee, Sang-Heon

    2015-03-01

    The continued development in the design technology of practical superconducting devices adopting high temperature superconductors tapes has led to a deeper understanding of their electromechanical behaviors. Rare-earth-barium-copper-oxide coated conductor (CC) tapes exhibit anisotropy of transport property (Ic) under magnetic field and its intrinsic strain effect is much significant depending on the orientation to the tape surface and the magnetic field intensity applied. Different experimental systems have already been developed to measure the relation of Ic with mechanical strain ε, magnetic field intensity B, and its angle of orientation, θ. However, few systems and instruments can measure these relationships simultaneously; either Ic-B-θ or Ic-ε-B is usually measured. In this study, a device which can measure these influences simultaneously based on a pair of permanent magnet systems was constructed and the characteristic responses of critical current Ic with strain, magnetic field, and its orientation with respect to the CC tape surface were investigated. The angular dependence of Ic with strain at 77 K in reactive co-evaporation by deposition and reaction GdBCO CC tapes has been measured using the permanent magnet system. The orientation angle of magnetic field with respect to the tape's surface was varied by rotating the rig fixture that holds a pair of permanent magnets. The strain sensitivity of Ic at different angles under low magnetic field was evaluated. As a result, a characteristic surface Ic (ε, θ, B) has been constructed as the characteristic response of Ic with strain and varying orientation under magnetic field.

  4. Carbon/Ternary Alloy/Carbon Optical Stack on Mylar as an Optical Data Storage Medium to Potentially Replace Magnetic Tape

    SciTech Connect

    Wang, Hao; Lunt, Barry M.; Gates, Richard J.; Asplund, Matthew C.; Shutthanandan, V.; Davis, Robert C.; Linford, Matthew R.

    2013-09-11

    A novel write-once-read-many (WORM) optical stack on Mylar tape is proposed as a replacement for magnetic tape for archival data storage. This optical tape contains a cosputtered bismuth–tellurium–selenium (BTS) alloy as the write layer sandwiched between thin, protective films of reactively sputtered carbon. The composition and thickness of the BTS layer were confirmed by Rutherford Backscattering (RBS) and atomic force microscopy (AFM), respectively. The C/BTS/C stack on Mylar was written to/marked by 532 nm laser pulses. Under the same conditions, control Mylar films without the optical stack were unaffected. Marks, which showed craters/movement of the write material, were characterized by optical microscopy and AFM. The threshold laser powers for making marks on C/BTS/C stacks with different thicknesses were explored. Higher quality marks were made with a 60× objective compared to a 40× objective in our marking apparatus. Finally, the laser writing process was simulated with COMSOL.

  5. Digital tape unit test facility software

    NASA Technical Reports Server (NTRS)

    Jackson, J. T.

    1971-01-01

    Two computer programs are described which are used for the collection and analysis of data from the digital tape unit test facility (DTUTF). The data are the recorded results of skew tests made on magnetic digital tapes which are used on computers as input/output media. The results of each tape test are keypunched onto an 80 column computer card. The format of the card is checked and the card image is stored on a master summary tape via the DTUTF card checking and tape updating system. The master summary tape containing the results of all the tape tests is then used for analysis as input to the DTUTF histogram generating system which produces a histogram of skew vs. date for selected data, followed by some statistical analysis of the data.

  6. Notes on some experiments on the application of subtractive compensation to USGS seismic magnetic tape recording and playback systems

    USGS Publications Warehouse

    Eaton, Jerry P.

    1975-01-01

    The purpose of these experiments is to lay the groundwork for the implementation of subtractive compensation of the USGS seismic network tape playbacks utilizing the Develco model 6203 discriminators at a x1 playback speed. Although the Develco discriminators were designed for this application and a matching Develco compensation discriminator was purchased, effective use of this system for subtractive compensation has been blocked by the inadequate (frequency dependent) matching of the phase of the compensation signal to that of the data signal at the point compensation is carried out in the data discriminators. John Van Schaack has ameliorated the phase mismatch problem by an empirical alteration of the compensation discriminator input bandpass filter. We have selected a set (of eight) Develco discriminators and adjusted their compensation signal input levels to minimize spurious signals (noise) originating from tape speed irregularities. The sensitivity of the data discriminators was adjusted so that deviations of +125 Hz and -125 Hz produced output signals of +2.00 volts and -2.00 volts, respectively. The eight data discriminators are driven by a multiplex signal on a single tape track (subcarriers 680, 1020, 1360, 1700, 2040, 2380, 2720, and 3060 Hz). The Develco-supplied compensation discriminator requires an unmodulated 3125 Hz signal on a separate tape track.

  7. French Tape Catalog.

    ERIC Educational Resources Information Center

    Blaney, Robert, Comp.

    This tape catalog is a complete list of all French-related titles appearing in the National Center for Audio Tapes 1974-76 catalog. Wherever possible, each tape is briefly described. Price and ordering information is included. (PMP)

  8. Tape transport mechanism

    DOEpatents

    Groh, Edward F.; McDowell, William; Modjeski, Norbert S.; Keefe, Donald J.; Groer, Peter

    1979-01-01

    A device is provided for transporting, in a stepwise manner, tape between a feed reel and takeup reel. An indexer moves across the normal path of the tape displacing it while the tape on the takeup reel side of the indexer is braked. After displacement, the takeup reel takes up the displaced tape while the tape on the feed reel side of the indexer is braked, providing stepwise tape transport in precise intervals determined by the amount of displacement caused by the indexer.

  9. Multimetal-Substituted Epsilon-Iron Oxide ϵ-Ga0.31 Ti0.05 Co0.05 Fe1.59 O3 for Next-Generation Magnetic Recording Tape in the Big-Data Era.

    PubMed

    Ohkoshi, Shin-Ichi; Namai, Asuka; Yoshikiyo, Marie; Imoto, Kenta; Tamazaki, Kazunori; Matsuno, Koji; Inoue, Osamu; Ide, Tsutomu; Masada, Kenji; Goto, Masahiro; Goto, Takashi; Yoshida, Takayuki; Miyazaki, Tatsuro

    2016-09-12

    From the viewpoints of large capacity, long-term guarantee, and low cost, interest in magnetic recording tapes has undergone a revival as an archive storage media for big data. Herein, we prepared a new series of metal-substituted ϵ-Fe2 O3 , ϵ-Ga(III) 0.31 Ti(IV) 0.05 Co(II) 0.05 Fe(III) 1.59 O3 , nanoparticles with an average size of 18 nm. Ga, Ti, and Co cations tune the magnetic properties of ϵ-Fe2 O3 to the specifications demanded for a magnetic recording tape. The coercive field was tuned to 2.7 kOe by introduction of single-ion anisotropy on Co(II) (S=3/2) along the c-axis. The saturation magnetization was increased by 44 % with Ga(III) (S=0) and Ti(IV) (S=0) substitution through the enhancement of positive sublattice magnetizations. The magnetic tape media was fabricated using an actual production line and showed a very sharp signal response and a remarkably high signal-to-noise ratio compared to the currently used magnetic tape.

  10. Multimetal-Substituted Epsilon-Iron Oxide ϵ-Ga0.31 Ti0.05 Co0.05 Fe1.59 O3 for Next-Generation Magnetic Recording Tape in the Big-Data Era.

    PubMed

    Ohkoshi, Shin-Ichi; Namai, Asuka; Yoshikiyo, Marie; Imoto, Kenta; Tamazaki, Kazunori; Matsuno, Koji; Inoue, Osamu; Ide, Tsutomu; Masada, Kenji; Goto, Masahiro; Goto, Takashi; Yoshida, Takayuki; Miyazaki, Tatsuro

    2016-09-12

    From the viewpoints of large capacity, long-term guarantee, and low cost, interest in magnetic recording tapes has undergone a revival as an archive storage media for big data. Herein, we prepared a new series of metal-substituted ϵ-Fe2 O3 , ϵ-Ga(III) 0.31 Ti(IV) 0.05 Co(II) 0.05 Fe(III) 1.59 O3 , nanoparticles with an average size of 18 nm. Ga, Ti, and Co cations tune the magnetic properties of ϵ-Fe2 O3 to the specifications demanded for a magnetic recording tape. The coercive field was tuned to 2.7 kOe by introduction of single-ion anisotropy on Co(II) (S=3/2) along the c-axis. The saturation magnetization was increased by 44 % with Ga(III) (S=0) and Ti(IV) (S=0) substitution through the enhancement of positive sublattice magnetizations. The magnetic tape media was fabricated using an actual production line and showed a very sharp signal response and a remarkably high signal-to-noise ratio compared to the currently used magnetic tape. PMID:27555528

  11. Volume server: A scalable high speed and high capacity magnetic tape archive architecture with concurrent multi-host access

    NASA Technical Reports Server (NTRS)

    Rybczynski, Fred

    1993-01-01

    A major challenge facing data processing centers today is data management. This includes the storage of large volumes of data and access to it. Current media storage for large data volumes is typically off line and frequently off site in warehouses. Access to data archived in this fashion can be subject to long delays, errors in media selection and retrieval, and even loss of data through misplacement or damage to the media. Similarly, designers responsible for architecting systems capable of continuous high-speed recording of large volumes of digital data are faced with the challenge of identifying technologies and configurations that meet their requirements. Past approaches have tended to evaluate the combination of the fastest tape recorders with the highest capacity tape media and then to compromise technology selection as a consequence of cost. This paper discusses an architecture that addresses both of these challenges and proposes a cost effective solution based on robots, high speed helical scan tape drives, and large-capacity media.

  12. Nonlinear Behavior of a Shim Coil in an LTS/HTS NMR Magnet With an HTS Insert Comprising Double-Pancake HTS-Tape Coils.

    PubMed

    Hahn, Seung-Yong; Ahn, Min Cheol; Bascuñán, Juan; Yao, Weijun; Iwasa, Yukikazu

    2009-06-01

    This paper reports results, experimental and analytical, of the nonlinear behavior of a shim coil in the presence of an HTS coil assembled with double-pancake (DP) HTS-tape coils. The experimental results are from: 1) operation of a 700 MHz LTS/HTS NMR magnet (LH700) consisting of a 600 MHz LTS NMR magnet (L600) equipped with superconducting shim coils and a 100 MHz DP-assembled HTS insert (H100) and; 2) an experiment with a room-temperature (RT) Z1 shim coil coupled to a 50 MHz DP-as-sembled HTS insert (H50). A field mapping theory with a harmonic analysis is applied to interpret both results. Based on experimental results and analyses, we conclude that the screening-current-induced field (SCF) generated by a DP-assembled HTS insert is primarily responsible for the nonlinear behavior, including strength degradation, of a shim coil.

  13. Nonlinear Behavior of a Shim Coil in an LTS/HTS NMR Magnet With an HTS Insert Comprising Double-Pancake HTS-Tape Coils

    PubMed Central

    Hahn, Seung-yong; Ahn, Min Cheol; Bascuñán, Juan; Yao, Weijun; Iwasa, Yukikazu

    2010-01-01

    This paper reports results, experimental and analytical, of the nonlinear behavior of a shim coil in the presence of an HTS coil assembled with double-pancake (DP) HTS-tape coils. The experimental results are from: 1) operation of a 700 MHz LTS/HTS NMR magnet (LH700) consisting of a 600 MHz LTS NMR magnet (L600) equipped with superconducting shim coils and a 100 MHz DP-assembled HTS insert (H100) and; 2) an experiment with a room-temperature (RT) Z1 shim coil coupled to a 50 MHz DP-as-sembled HTS insert (H50). A field mapping theory with a harmonic analysis is applied to interpret both results. Based on experimental results and analyses, we conclude that the screening-current-induced field (SCF) generated by a DP-assembled HTS insert is primarily responsible for the nonlinear behavior, including strength degradation, of a shim coil. PMID:20383282

  14. Fabrication of Yb-123 Tapes

    SciTech Connect

    Athur, S.; Balachandran, U.; Salama, K.

    2000-11-15

    While Bi-2223 tapes have been the workhorses of the superconductor industry, their poor performance in applied magnetic fields restrict their use to below 30 K. Melt-processing of Ag-clad Yb-123 PIT tapes offers a simple and scalable technique for fabricating long-length HTS conductors capable of being used at 77 K. Under reduced oxygen partial pressure, the peritectic temperature of Yb-123 is below the melting point of Ag, and this facilitates the adaptation of melt-texturing methods for fabricating these tapes. The effect of melt-processing temperature on current density was also explored; a temperature of 965 C yielded optimal critical current values. The critical current density achieved at 4.2 K was 20,000 A/cm{sup 2}, corresponding to a critical current of 52 A. Based on the above results, an optimal processing zone for melt-processing of Ag-clad Yb-123 tapes was determined. These results hold promise for melt-processing of Ag-clad Yb-123 tapes as an alternative to Bi-2223 PIT technology.

  15. Specification for IBM/IBM compatible 3480 tape cartridge

    NASA Technical Reports Server (NTRS)

    Perry, Jimmy L.

    1988-01-01

    This document establishes the same kinds of standards and controls that are currently in use for the procurement on new analog and digital magnetic tapes. The Magnetic Tape Certification Facility (MTCF) currently maintains a Quality Products List (QPL) for all new analog and digital magnetic tapes purchased by NASA-GSFC. Extensive tests are conducted in the MTCF on an annual basis to determine the manufacturer's tape types to be added to or deleted from the current QPL. The MTCF currently maintains two specifications for magnetic tapes: NASA TM-79724 is used for the QPL and acceptance testing of new analog tapes; and NASA TM-80599 is used for the QPL and acceptance testing of new digital tapes. This specification will be used for the QPL and acceptance testing of new 3480 cartridges. The magnetic tapes used by GSFC, LaRC, ARC/Dryden, WFF, and the Network Tracking Stations are covered by the NASA-GSFC specifications. The 3480 cartridge was introduced approximately 3.5 years ago and is becoming an increasingly attractive alternative to digital magnetic tapes. Many users have already converted to the 3480 system and have more tape drives on order.

  16. Development of advanced barium ferrite tape media

    NASA Astrophysics Data System (ADS)

    Shimizu, Osamu; Oyanagi, Masahito; Morooka, Atsushi; Mori, Masahiko; Kurihashi, Yuich; Tada, Toshio; Suzuki, Hiroyuki; Harasawa, Takeshi

    2016-02-01

    We developed an advanced particulate magnetic tape using fine barium ferrite (BaFe) particles for magnetic-tape storage systems. The new tape showed a signal-to-noise ratio (SNR) that was 3.5 dB higher than that of the commercially available BaFe tape used for the Linear Tape Open generation 6 tape-storage system, at a linear density of 300 kfci measured with a giant magnetoresistive head with a reader width of 0.45 μm. Such significant increase in SNR was achieved by reducing the magnetic particle volume from 1950 to 1350 nm3, while maintaining a sufficiently high thermal stability, improving the perpendicular squareness ratio from 0.66 to 0.83, and improving the surface roughness from 2.5 to 2.0 nm when measured by atomic force microscopy and from 2.4 to 0.9 nm when measured by optical interferometry. This paper describes the characteristics of the new BaFe particles and media, which are expected to be employed for future high-capacity linear-tape systems.

  17. ERB master archival tape specification no. T 134081 ERB MAT, revision 1

    NASA Technical Reports Server (NTRS)

    1984-01-01

    The Earth radiation budget (ERB)MAT tapes are generated by the ERB MATGEN software using the IBM 3081 computer system operated by the Science and Applications Computer Center at Goddard Space Flight Center. All MAT's are 9-track and MAT data are in ascending time order. The gross tape format for NIMBUS year-1 and year-2 MAT's is different from the format of MAT's starting with year-3. The MATs from the first two years are to contain one day's worth of data while all other MATs are to contain multiple day's worth of data stacked onto the tapes.

  18. Tape reading fixture

    NASA Technical Reports Server (NTRS)

    1969-01-01

    Commercially available roller type desk pad provides an efficient and orderly manner of handling rolled paper tapes for proofreading. The fixture, which is modified to accept Flex-O-Writer or similar tapes and roll them in either direction, reduces the chance of damaging or soiling the tapes through repeated handling.

  19. A Proposed Convention for Writing FITS Data Tapes: DRAFT 0

    NASA Astrophysics Data System (ADS)

    ROSAT/ASCA/Xte Development Team

    Even with today's advances in networking, file system capacities and CD technology it is often necessary to transport and store scientific data sets on magnetic tape. The FITS data format standard contains guidelines on how to write FITS files to magnetic tape but does not address the problem of indexing or organizing tape files. Currently available magnetic tape media can store multiple gigabytes of information on a single tape, which translates into thousands of FITS files per tape. Thus, the lack of a standard tape indexing and organizing scheme can, in many instances, become a serious problem. Faced with the above dilemma, the Astrophysics Data Facility at Goddard Space Flight Center has developed a simple in-house convention for indexing the contents of FITS data tapes that allows software to quickly and easily inventory tape contents. This paper describes the convention used by our organization. We propose that this convention be adopted into the FITS standard as the way to index and organize the contents of magnetic tape media.

  20. Thermoplastic tape compaction device

    DOEpatents

    Campbell, Vincent W.

    1994-01-01

    A device for bonding a thermoplastic tape to a substrate to form a fully consolidated composite. This device has an endless chain associated with a frame so as to rotate in a plane that is perpendicular to a long dimension of the tape, the chain having pivotally connected chain links with each of the links carrying a flexible foot member that extends outwardly from the chain. A selected number of the foot members contact the tape, after the heating thereof, to cause the heated tape to bond to the substrate. The foot members are each a thin band of metal oriented transversely to the chain, with a flexibility and width and length to contact the tape so as to cause the tape to conform to the substrate to achieve consolidation of the tape and the substrate. A biased leaf-type spring within the frame bears against an inner surface of the chain to provide the compliant pressure necessary to bond the tape to the substrate. The chain is supported by sprockets on shafts rotatably supported in the frame and, in one embodiment, one of the shafts has a drive unit to produce rotation such that the foot members in contact with the tape move at the same speed as the tape. Cooling jets are positioned along the frame to cool the resultant consolidated composite.

  1. Thermoplastic tape compaction device

    DOEpatents

    Campbell, V.W.

    1994-12-27

    A device is disclosed for bonding a thermoplastic tape to a substrate to form a fully consolidated composite. This device has an endless chain associated with a frame so as to rotate in a plane that is perpendicular to a long dimension of the tape, the chain having pivotally connected chain links with each of the links carrying a flexible foot member that extends outwardly from the chain. A selected number of the foot members contact the tape, after the heating thereof, to cause the heated tape to bond to the substrate. The foot members are each a thin band of metal oriented transversely to the chain, with a flexibility and width and length to contact the tape so as to cause the tape to conform to the substrate to achieve consolidation of the tape and the substrate. A biased leaf-type spring within the frame bears against an inner surface of the chain to provide the compliant pressure necessary to bond the tape to the substrate. The chain is supported by sprockets on shafts rotatably supported in the frame and, in one embodiment, one of the shafts has a drive unit to produce rotation such that the foot members in contact with the tape move at the same speed as the tape. Cooling jets are positioned along the frame to cool the resultant consolidated composite. 5 figures.

  2. Specification for wide channel bandwidth one-inch video tape

    NASA Technical Reports Server (NTRS)

    Perry, Jimmy L.

    1988-01-01

    Standards and controls are established for the procurement of wide channel bandwidth one inch video magnetic recording tapes for Very Long Base Interferometer (VLBI) system applications. The Magnetic Tape Certification Facility (MTCF) currently maintains three specifications for the Quality Products List (QPL) and acceptance testing of magnetic tapes. NASA-TM-79724 is used for the QPL and acceptance testing of new analog tapes; NASA-TM-80599 is used for QPL and acceptance testing of new digital tapes; and NASA-TM-100702 is used for the QPL and acceptance testing of new IBM/IBM compatible 3480 magnetic tape cartridges. This specification will be used for the QPL and acceptance testing of new wide channel bandwidth one inch video magnetic recording tapes. The one inch video tapes used by the Jet Propulsion Lab., the Deep Space Network and the Haystack Observatory will be covered by this specification. These NASA stations will use the video tapes for their VLBI system applications. The VLBI system is used for the tracking of quasars and the support of interplanetary exploration.

  3. The High Field Magnetic Dependence of Critical Current Density at 4.2 K for Ag-Sheathed Bi2Sr2CaCu2Oy Superconducting Tape

    NASA Astrophysics Data System (ADS)

    Enomoto, Noritsugu; Kikuchi, Hiroyuki; Uno, Naoki; Kumakura, Hiroaki; Togano, Kazumasa; Watanabe, Kazuo

    1990-03-01

    Critical current density (Jc) at 4.2 K and its dependence on applied magnetic field was measured for Ag-sheathed Bi2Sr2CaCu2Oy superconducting tape. The specimen showed a strong grain alignment which could be attained by adjusting the conditions of heat treatment. The degree of crystal orientation (F) was evaluated to be up to 95% by XRD for this specimen. In the case of magnetic field applied in a direction parallel to the tape, the Jc initially decreased with the magnetic field from 1.2× 105 A/cm2 at 1 T to 5× 104 A/cm2 at 10T and then remained almost constant up to 23 T. As the F value decreased from 95%, Jc also decreased. The pinning force (Fp) of the 95%-F-value tape was estimated to be about 1× 1010 N/m3 at 23 T. This value is larger than those of conventional low-Tc superconductors.

  4. Duct Tape Durability Testing

    SciTech Connect

    Sherman, Max H.; Walker, Iain S.

    2004-04-01

    Duct leakage is a major source of energy loss in residential buildings. Most duct leakage occurs at the connections to registers, plenums, or branches in the duct system. At each of these connections, a method of sealing the duct system is required. Typical sealing methods include tapes or mastics applied around the joints in the system. Field examinations of duct systems have shown that taped seals tend to fail over extended periods of time. The Lawrence Berkeley National Laboratory (LBNL) has been testing sealant durability for several years using accelerated test methods and found that typical duct tape (i.e., cloth-backed tapes with natural rubber adhesives) fails more rapidly than other duct sealants. This report summarizes the results of duct sealant durability testing over two years for four UL 181B-FX listed duct tapes (two cloth tapes, a foil tape and an Oriented Polypropylene (OPP) tape). One of the cloth tapes was specifically developed in collaboration with a tape manufacturer to perform better in our durability testing. The tests involved the aging of common ''core-to-collar joints'' of flexible duct to sheet metal collars. Periodic air leakage tests and visual inspection were used to document changes in sealant performance. After two years of testing, the flex-to-collar connections showed little change in air leakage, but substantial visual degradation from some products. A surprising experimental result was failure of most of the clamps used to mechanically fasten the connections. This indicates that the durability of clamps also need to be addressed ensure longevity of the duct connection. An accelerated test method developed during this study has been used as the basis for an ASTM standard (E2342-03).

  5. Digital terrain tapes: user guide

    USGS Publications Warehouse

    ,

    1980-01-01

    DMATC's digital terrain tapes are a by-product of the agency's efforts to streamline the production of raised-relief maps. In the early 1960's DMATC developed the Digital Graphics Recorder (DGR) system that introduced new digitizing techniques and processing methods into the field of three-dimensional mapping. The DGR system consisted of an automatic digitizing table and a computer system that recorded a grid of terrain elevations from traces of the contour lines on standard topographic maps. A sequence of computer accuracy checks was performed and then the elevations of grid points not intersected by contour lines were interpolated. The DGR system produced computer magnetic tapes which controlled the carving of plaster forms used to mold raised-relief maps. It was realized almost immediately that this relatively simple tool for carving plaster molds had enormous potential for storing, manipulating, and selectively displaying (either graphically or numerically) a vast number of terrain elevations. As the demand for the digital terrain tapes increased, DMATC began developing increasingly advanced digitizing systems and now operates the Digital Topographic Data Collection System (DTDCS). With DTDCS, two types of data elevations as contour lines and points, and stream and ridge lines are sorted, matched, and resorted to obtain a grid of elevation values for every 0.01 inch on each map (approximately 200 feet on the ground). Undefined points on the grid are found by either linear or or planar interpolation.

  6. NIMBUS 7 Earth Radiation Budget (ERB) Matrix User's Guide. Volume 2: Tape Specifications

    NASA Technical Reports Server (NTRS)

    Ray, S. N.; Vasanth, K. L.

    1984-01-01

    The ERB MATRIX tape is generated by an IBM 3081 computer program and is a 9 track, 1600 BPI tape. The gross format of the tape given on Page 1, shows an initial standard header file followed by data files. The standard header file contains two standard header records. A trailing documentation file (TDF) is the last file on the tape. Pages 9 through 17 describe, in detail, the standard header file and the TDF. The data files contain data for 37 different ERB parameters. Each file has data based on either a daily, 6 day cyclic, or monthly time interval. There are three types of physical records in the data files; namely, the world grid physical record, the documentation mercator/polar map projection physical record, and the monthly calibration physical record. The manner in which the data for the 37 ERB parameters are stored in the physical records comprising the data files, is given in the gross format section.

  7. Low-cost tape system measures velocity of acceleration

    NASA Technical Reports Server (NTRS)

    Hartenstein, R.

    1964-01-01

    By affixing perforated magnetic recording tape to the falling end of a body, acceleration and velocity were measured. The measurement was made by allowing the tape to pass between a light source and a photoelectric sensor. Data was obtained from a readout device.

  8. Contact Recording on Bidirectional Thin-Film Tape Head Structures

    NASA Astrophysics Data System (ADS)

    Brock, George W.; Connolly, Derry; Czarnecki, W. Stanley

    A transversely slotted magnetic recording head for high density tape drives is characterized theoretically for geometry and experimentally for wear and durability under different environmental conditions, tape substrate thicknesses, recording head substrate materials, and wear resistant overcoat materials. The triple bump recording head structure, which allows read-after-write in both directions of tape motion, has transverse slots placed in the head to produce contact between the tape and the read/write gap locations. A through slot "video" style contour design is also presented and analyzed.

  9. Transport and magnetization current in a thin layer of Bi{sub 1.8}Pb{sub 0.4}Sr{sub 2.0}Ca{sub 2.2}Cu{sub 3.0}O{sub y} adjacent to silver sheathing in BSCCO-2223 tapes

    SciTech Connect

    Lelovic, M.; Krishnaraj, P.; Deis, T.

    1995-07-01

    The thin superconducting region next to the silver sheath appears to be the region of high critical current density in BSCCO-2223 tapes. Transport current measurements on Bi{sub 1.8}Pb{sub 0.4}Sr{sub 2.0}Ca{sub 2.2}Cu{sub 3.0}O{sub y} tape at 77 K in a low magnetic field applied parallel to the tape thickness indicate an exponential field dependence [J / J{sub c} {proportional_to} exp (- B / B{sub 0})] for transport currents. Magnetic hysteresis was measured in a 10-{mu}m-thick layer of superconductor near the silver sheath as a function of temperature, intensity, and orientation of applied field with respect to the tape. The characteristic field for full penetration depth, B*, for a superconducting slab was found to have a power law dependence on temperature. Magnetization currents as a function of temperature and applied field oriented parallel to the tape thickness, J{sub c,m}(B,T), were determined from the magnetization loop width with a Bean- model expression adapted for an orthorhombic sample. The critical-state model, adjusted for scaling and magnetic relaxation, correlates well with the magnetization current of the thin layer at 77 K.

  10. Caught (Unfortunately) on Tape

    ERIC Educational Resources Information Center

    Young, Jeffrey R.

    2009-01-01

    Recording class sessions so students can view them online is becoming routine on many campuses. But all that taping can lead to "uh-oh moments," such as when a professor's joke about the college dean ends up on YouTube, or a private comment to a student after class is inadvertently broadcast. Some lecture bloopers caught on tape are funny (well,…

  11. Artificial Intelligence Controls Tape-Recording Sequence

    NASA Technical Reports Server (NTRS)

    Schwuttke, Ursula M.; Otamura, Roy M.; Zottarelli, Lawrence J.

    1989-01-01

    Developmental expert-system computer program intended to schedule recording of large amounts of data on limited amount of magnetic tape. Schedules recording using two sets of rules. First set incorporates knowledge of locations for recording of new data. Second set incorporates knowledge about issuing commands to recorder. Designed primarily for use on Voyager Spacecraft, also applicable to planning and sequencing in industry.

  12. Fabrication and characterization of Ag-clad Bi-2223 tapes.

    SciTech Connect

    Balachandran, U.

    1999-04-20

    The powder-in-tube (PIT) technique was used to fabricate multifilament (Bi,Pb){sub 2}Sr{sub 2}Ca{sub 2}Cu{sub 3}O{sub y} (Bi-2223) superconducting tapes. Transport current properties of these tapes were enhanced by increasing the packing density of the precursor powder and improving the mechanical deformation condition. A critical current (I{sub c}) of > 35 A in long lengths (> 200 m) tapes has been achieved. In measuring the dependence of critical current density on magnetic field and temperature for the optimally processed tapes, we found a J{sub c} of > 10{sup 4} A/cm{sup 2} at 20 K in magnetic fields up to 3 T and parallel to the c-axis, which is of interest for use in refrigerator-cooled magnets. I{sub c} declined exponentially when an external field was applied perpendicular to the tape surface at 77 K. Mechanical stability was tested for tapes sheathed with pure Ag and Ag-Mg alloy. Tapes made with pure Ag sheathing can withstand a tensile stress of {approx}20 MPa with no detrimental effect on I{sub c} values. Mechanical performance was improved by using Ag-Mg alloy sheathing: values of transport critical current began to decrease at the tensile stress of {approx} 100 MPa. Transport current measurements on tapes wound on a mandrel of 3.81 cm (1.5 in.) diameter at 30{degree} to the longitudinal axis, showed a reduction of {approx} 10% in I{sub c} values for pure Ag-sheathed tapes and 5% reduction in I{sub c} values for Ag-Mg sheathed tapes, compared with the I{sub c} values of as-coiled tapes.

  13. Probes for investigating the effect of magnetic field, field orientation, temperature and strain on the critical current density of anisotropic high-temperature superconducting tapes in a split-pair 15 T horizontal magnet

    SciTech Connect

    Sunwong, P.; Higgins, J. S.; Hampshire, D. P.

    2014-06-15

    We present the designs of probes for making critical current density (J{sub c}) measurements on anisotropic high-temperature superconducting tapes as a function of field, field orientation, temperature and strain in our 40 mm bore, split-pair 15 T horizontal magnet. Emphasis is placed on the design of three components: the vapour-cooled current leads, the variable temperature enclosure, and the springboard-shaped bending beam sample holder. The vapour-cooled brass critical-current leads used superconducting tapes and in operation ran hot with a duty cycle (D) of ∼0.2. This work provides formulae for optimising cryogenic consumption and calculating cryogenic boil-off, associated with current leads used to make J{sub c} measurements, made by uniformly ramping the current up to a maximum current (I{sub max}) and then reducing the current very quickly to zero. They include consideration of the effects of duty cycle, static helium boil-off from the magnet and Dewar (b{sup ′}), and the maximum safe temperature for the critical-current leads (T{sub max}). Our optimized critical-current leads have a boil-off that is about 30% less than leads optimized for magnet operation at the same maximum current. Numerical calculations show that the optimum cross-sectional area (A) for each current lead can be parameterized by LI{sub max}/A=[1.46D{sup −0.18}L{sup 0.4}(T{sub max}−300){sup 0.25D{sup −{sup 0{sup .{sup 0{sup 9}}}}}}+750(b{sup ′}/I{sub max})D{sup 10{sup −{sup 3I{sub m}{sub a}{sub x}−2.87b{sup ′}}}}]× 10{sup 6}A m{sup −1} where L is the current lead's length and the current lead is operated in liquid helium. An optimum A of 132 mm{sup 2} is obtained when I{sub max} = 1000 A, T{sub max} = 400 K, D = 0.2, b{sup ′} = 0.3 l h{sup −1} and L = 1.0 m. The optimized helium consumption was found to be 0.7 l h{sup −1}. When the static boil-off is small, optimized leads have a boil-off that can be roughly parameterized by: b/I{sub max } ≈ (1.35 × 10

  14. Tests of the standard (30 hz) NCER FM multiplex telemetry system, augmented by two timing channels and a compensation reference signal, used to record multiplexed seismic network data on magnetic tape

    USGS Publications Warehouse

    Eaton, Jerry P.

    1976-01-01

    The application of subtractive compensation to USGS seismic magnetic tape recording and playback systems was examined in a recent USGS Open-file report (1). It was found, for the standard (30 Hz) NCER multiplex system, that subtractive compensation utilizing a 4688 Hz reference signal multiplexed onto each data track was more effective than that utilizing a 3125 Hz reference signal recorded separately on a different track. Moreover, it was found that the portion of the spectrum between the uppermost data channel (3060 Hz + or - 125 Hz) and the compensation reference signal (4688 Hz) could be used to record an additional timing signal, with a center frequency of 3700 Hz and a broader playback bandwidth (ca 0 to 100 Hz) than that of the standard data channels. Accordingly, for the tests described in that report, the standard 8-datachannel multiplex system was augmented by one additional timing channel with a center frequency of 3700 Hz. The 3700 Hz discriminator used in those tests was not successfully set up to utilize subtractive compensation; so its output from a tape playback was quite noisy. Subsequently, further tests have been carried out on the application of subtractive compensation to a 4-channel broad-band multiplex system and to the standard multiplex system, both recorded on field tape recorders with relatively poor tape speed control (2), (3). In the course of these experiments, it was discovered that two separate timing channe1s, not just one, can be inserted between the uppermost data channel and the compensation reference signal, Furthermore, it was possible to adjust the discriminators used to playback these timing channels so that they profited significantly from subtractive compensation even though the playback bandwidth was 0 to 100 Hz (for short rise times of square wave timing signals). The advantages of recording two timing signals on each data track include: 1) one standard time signal to be used for critical timing, e.g. IRIG E, can be

  15. Recording-tape position sensor

    NASA Technical Reports Server (NTRS)

    Schoppet, G. C.

    1977-01-01

    Device uses tachometer pulses from capstan and reset pulse from one reel to sense count of tach pulses per revolution of reel. Number of pulses is direct measurement of tape stack radius and is independent of tape speed or direction.

  16. Current Distribution in Wide YBCO Tapes

    NASA Astrophysics Data System (ADS)

    Carrera, M.; Granados, X.; Amorós, J.; Puig, T.; Obradors, X.

    The need of a better mechanical behaviour and the stabilization of coated conductors for applications, as Magnets, cables or Fault Current Limiters, has motivated the lamination of tapes with stainless steel or copper alloys, increasing so the elastic modulus of the conductors and their mechanical performance. Some of the stainless steels used are magnetic, thus introducing some perturbations of the current flow when energizing the conductor. In order to detect these possible perturbations, the magnetic self field in the surface of the tape has been explored by Hall mapping technique at several current loads in a monotonically driven cyclic sequence. By increasing current steps when loading up, crossing the critical field threshold, and decreasing down to remanent state. Deviation from the expected magnetic map has been observed. In this work, we will report on the resulting measurements, and the current flow is calculated by solving the inverse problem for a 12 mm wide stainless steel reinforced Coated Conductor tape. We discuss on the likely origin of the observed perturbations.

  17. Unrecorded wideband instrumentation reference tape feasibility study: Frequency response results

    NASA Astrophysics Data System (ADS)

    Hust, D. R.

    1980-03-01

    An investigation was conducted to determine signal response variations when a variety of wideband instrumentation magnetic tapes is used on a cross section of recorder/reproducer systems. Data for the investigation were collected by transmitting a set of eight sample test tapes to participating data recording/reproducing facilities for the purpose of making data measurements. Data collected represent measurements made with 16 different recorder/reproducer systems at 11 different testing facilities located throughout the United States. The data-collection process involved approximately 2 years of testing. The originating/coordinating facility was the Pacific Missile Test Center, Point Mugu, California. The test results indicated the following: all of the sample test tapes exhibited bidirectional performance within the limits of measurement repeatability; overall system stability was better in the low-band regions than in the upper-band regions; and the overall relative frequency response of the sample test tapes did not change appreciably during the 2 year investigative period. The most significant result of the test measurements is that at least 90% of the frequency response values were within + or - 2.0 dB at all frequencies. Machine stability factors such as azimuth, equalizer, and gain changes had more effect on data variability than did magnetic tape or tape speed. The use of a reference tape system is recommended as a method to assure that relative frequency response variations will be less than or equal to + or - 2.0 dB.

  18. Tamper tape seals

    SciTech Connect

    Wright, B.W.; Undem, H.A.

    1994-07-01

    Tamper tapes are appealing for many applications due to their ease of use and relative robustness. Applications include seals for temporary area denial, protection of sensitive equipment, chain-of-custody audit trails, and inventory control practices. A next generation of adhesive tamper tapes is being developed that combines the best features of commercially available devices with additional state-of-the-art features in tamper indication, tamper-resistance, and counterfeit-resistance. The additional features are based on U.S. Department of Energy (DOE) research and development (R&D) activities that were originally associated with preparations for the Strategic Arms Reduction Treaty (START). New features include rapid-set, chemical-cure adhesive systems that allow user-friendly application and layered levels of counterfeit-resistance based on unique {open_quotes}fingerprint{close_quotes} characteristics that can be accessed as desired.

  19. Melt processing of Yb-123 tapes

    SciTech Connect

    Athur, S. P.; Balachandran, U.; Salama, K.

    2000-02-17

    The innovation of a simple, scalable process for manufacturing long-length conductors of HTS is essential to potential commercial applications such as power cables, magnets, and transformers. In this paper the authors demonstrate that melt processing of Yb-123 tapes made by the PIT route is an alternative to the coated conductor and Bi-2223 PIT tape fabrication techniques. Ag-clad Yb-123 tapes were fabricated by groove rolling and subsequently, melt processed in different oxygen partial pressures in a zone-melting furnace with a gradient of 140 C/cm. The transition temperatures measured were found to be around 81 K undermost processing conditions. EPMA of the tapes processed under different conditions show the 123 phase to be Ba deficient and Cu and Yb rich. Critical current was measured at various temperatures from 77 K to 4.2 K. The J{sub c} increased with decrease in pO{sub 2}. The highest I{sub c} obtained was 52 A at 4.2 K.

  20. Tape Placement Head for Applying Thermoplastic Tape to an Object

    NASA Technical Reports Server (NTRS)

    Cope, Ralph D. (Inventor); Funck, Steve B. (Inventor); Gruber, Mark B. (Inventor); Lamontia, Mark A. (Inventor); Johnson, Anthony D. (Inventor)

    2008-01-01

    A tape placement head for applying thermoplastic tape to an object includes a heated feeder which guides the tape/tow to a heated zone. The heated zone has a line compactor having a single row of at least one movable heated member. An area compactor is located in the heated zone downstream from the line compactor. The area compactor includes a plurality of rows of movable feet which are extendable toward the tape/tow different distances with respect to each other to conform to the shape of the object. A shim is located between the heated compactors and the tape/tow. A chilled compactor is in a chilled zone downstream from the heated zone. The chilled zone includes a line chilled compactor and an area chilled compactor. A chilled shim is mounted between the chilled compactor and the tape/tow.

  1. Induction Bonding of Prepreg Tape and Titanium Foil

    NASA Technical Reports Server (NTRS)

    Messier, Bernadette C.; Hinkley, Jeffrey A.; Johnston, Norman J.

    1998-01-01

    Hybrid structural laminates made of titanium foil and carbon fiber reinforced polymer composite offer a potential for improved performance in aircraft structural applications. To obtain information needed for the automated fabrication of hybrid laminates, a series of bench scale tests were conducted of the magnetic induction bonding of titanium foil and thermoplastic prepreg tape. Foil and prepreg specimens were placed in the gap of a toroid magnet mounted in a bench press. Several magnet power supplies were used to study power at levels from 0.5 to 1.75 kW and frequencies from 50 to 120 kHz. Sol-gel surface-treated titanium foil, 0.0125 cm thick, and PIXA/IM7 prepreg tape were used in several lay-up configurations. Data were obtained on wedge peel bond strength, heating rate, and temperature ramp over a range of magnet power levels and frequencies at different "power-on" times for several magnet gap dimensions. These data will be utilized in assessing the potential for automated processing. Peel strengths of foil-tape bonds depended on the maximum temperature reached during heating and on the applied pressure. Maximum peel strengths were achieved at 1.25kW and 8OkHz. Induction heating of the foil appears to be capable of good bonding up to 10 plies of tape. Heat transfer calculations indicate that a 20-40 C temperature difference exists across the tape thickness during heat-up.

  2. Fully synthetic taped insulation cables

    DOEpatents

    Forsyth, Eric B.; Muller, Albert C.

    1984-01-01

    A high voltage oil-impregnated electrical cable with fully polymer taped insulation operable to 765 kV. Biaxially oriented, specially processed, polyethylene, polybutene or polypropylene tape with an embossed pattern is wound in multiple layers over a conductive core with a permeable screen around the insulation. Conventional oil which closely matches the dielectric constant of the tape is used, and the cable can be impregnated after field installation because of its excellent impregnation characteristics.

  3. Reflectance characterization of tape-based plasma mirrors

    NASA Astrophysics Data System (ADS)

    Shaw, B. H.; Steinke, S.; van Tilborg, J.; Leemans, W. P.

    2016-06-01

    Specular reflections of relativistic laser pulses from an overdense plasma mirror (PM) were studied experimentally. The pointing stability of the PM and reflectance of the input laser were characterized. The solid material used for the PM was a VHS tape. This study was done for the magnetic and plastic sides of the VHS tape, and for input light of both s and p-polarizations. The laser pulse fluence was varied by changing the focus position relative to the tape surface, which changed the spot size at the tape. The pointing fluctuations of the reflected pulses caused by the PM were ≃1 mrad. A peak reflectance of 82% was obtained from the plastic surface of the VHS tape when focusing s-polarized light 4 mm from the tape surface (the wavefront quality was confirmed to be conserved). An analytic model was developed to understand the physics of the interaction for each tape material and polarization. Fitting of our model parameters to the experimental results allowed an estimate of the key plasma parameters such as plasma expansion velocity, ionization intensity, and fraction of absorbed laser energy.

  4. A terabyte linear tape recorder

    NASA Technical Reports Server (NTRS)

    Webber, John C.

    1994-01-01

    A plan has been formulated and selected for a NASA Phase 2 SBIR award for using the VLBA tape recorder for recording general data. The VLBA tape recorder is a high-speed, high-density linear tape recorder developed for Very Long Baseline Interferometry (VLBI) which is presently capable of recording at rates up to 2 Gbit/sec and holding up to 1 Terabyte of data on one tape, using a special interface and not employing error correction. A general-purpose interface and error correction will be added so that the recorder can be used in other high-speed, high-capacity applications.

  5. Tape casting of magnesium oxide.

    SciTech Connect

    Ayala, Alicia; Corral, Erica L.; Loehman, Ronald E.; Bencoe, Denise Nora; Reiterer, Markus; Shah, Raja A.

    2008-02-01

    A tape casting procedure for fabricating ceramic magnesium oxide tapes has been developed as a method to produce flat sheets of sintered MgO that are thin and porous. Thickness of single layer tapes is in the range of 200-400 {micro}m with corresponding surface roughness values in the range of 10-20 {micro}m as measured by laser profilometry. Development of the tape casting technique required optimization of pretreatment for the starting magnesium oxide (MgO) powder as well as a detailed study of the casting slurry preparation and subsequent heat treatments for sintering and final tape flattening. Milling time of the ceramic powder, plasticizer, and binder mixture was identified as a primary factor affecting surface morphology of the tapes. In general, longer milling times resulted in green tapes with a noticeably smoother surface. This work demonstrates that meticulous control of the entire tape casting operation is necessary to obtain high-quality MgO tapes.

  6. Multifilamentary niobium tin superconductor tape

    NASA Technical Reports Server (NTRS)

    Brisbin, P. H.; Coles, W. D.

    1975-01-01

    In the method proposed for fabricating multifilamentary Nb3Sn tape, filamentary superconducting paths are produced in standard commercial superconductor tape by chemical milling of separator slots through the Nb3Sn layer. The multifilament configuration features a matrix of ten 1.2 mm wide parallel helical superconducting paths along the length of the tape. The paths are spaced 0.4 mm apart. Tapes tested as small pancake coils demonstrated the integrity and continuity of the matrix, and showed that critical current was sustained in direct proportion to retained superconductor.

  7. AC loss in stacks of Bi-2223/Ag tapes modified with ferromagnetic covers at the edges

    NASA Astrophysics Data System (ADS)

    Safran, S.; Gömöry, F.; Gencer, Ali

    2010-10-01

    We investigated the magnetization loss of stacked Bi-2223/Ag tapes with a ferromagnetic cover on the edges. Such modification has been found recently to reduce the AC loss of a single tape; however, the behavior in a coil winding could be different. With experiments and numerical calculations we show that a ferromagnetic cover on the edges of a superconducting tape could reduce its magnetization loss also when the tapes are arranged in a stack. The effect is weaker for larger numbers of tapes but nevertheless remained significant in a stack of four tapes, which was the maximum number studied here. The effects observed experimentally are nicely explained by the results of numerical calculations.

  8. Centrally managed tapes at DESY

    SciTech Connect

    Hell, O.

    1994-12-31

    Tapes at DESY are managed by the computer center and thus offer virtually unlimited storage space to the DESY computer center users. This paper describes the most recent version of the DESY tape management system, its predecessors having been in service for many years.

  9. Sharpen Your Skills: Tape Recording.

    ERIC Educational Resources Information Center

    Perry, Helen

    1984-01-01

    Three short articles provide tape recording instructions for braille transcribers and teachers of the visually handicapped, for transcribing instructional materials. The first article gives instructions for creating a "mini" table of contents, or index, to be inserted at the beginning of each tape. The second article provides instructions for…

  10. Wire and Packing Tape Sandwiches

    ERIC Educational Resources Information Center

    Rabinowitz, Sandy

    2009-01-01

    In this article, the author describes how students can combine craft wire with clear packing tape to create a two-dimensional design that can be bent and twisted to create a three-dimensional form. Students sandwich wire designs between two layers of tape. (Contains 1 online resource.)

  11. Tape/head interface study

    NASA Technical Reports Server (NTRS)

    1983-01-01

    Existing high energy tapes, high track density heads, and transport guidance techniques were evaluated and characterized to enable these technologies to be employed in future spacecraft recorders with high confidence. The results of these study efforts demonstrated tracking accuracy tape and head density that will support spacecraft recorders with data rates of a minimum of 150 Mbps and storage capacities ranging from 10 to the 10th to 10 to the 11th bits. Seven high energy tapes of either .25 in width, 1.00 in width, or both, were tested. All tapes were tested at the same speed (30 ips) and the same packing density (33 KBI). The performance of all 1 in tapes was considered superior.

  12. DICOM implementation on online tape library storage system

    NASA Astrophysics Data System (ADS)

    Komo, Darmadi; Dai, Hailei L.; Elghammer, David; Levine, Betty A.; Mun, Seong K.

    1998-07-01

    The main purpose of this project is to implement a Digital Image and Communications (DICOM) compliant online tape library system over the Internet. Once finished, the system will be used to store medical exams generated from U.S. ARMY Mobile ARMY Surgical Hospital (MASH) in Tuzla, Bosnia. A modified UC Davis implementation of DICOM storage class is used for this project. DICOM storage class user and provider are implemented as the system's interface to the Internet. The DICOM software provides flexible configuration options such as types of modalities and trusted remote DICOM hosts. Metadata is extracted from each exam and indexed in a relational database for query and retrieve purposes. The medical images are stored inside the Wolfcreek-9360 tape library system from StorageTek Corporation. The tape library system has nearline access to more than 1000 tapes. Each tape has a capacity of 800 megabytes making the total nearline tape access of around 1 terabyte. The tape library uses the Application Storage Manager (ASM) which provides cost-effective file management, storage, archival, and retrieval services. ASM automatically and transparently copies files from expensive magnetic disk to less expensive nearline tape library, and restores the files back when they are needed. The ASM also provides a crash recovery tool, which enable an entire file system restore in a short time. A graphical user interface (GUI) function is used to view the contents of the storage systems. This GUI also allows user to retrieve the stored exams and send the exams to anywhere on the Internet using DICOM protocols. With the integration of different components of the system, we have implemented a high capacity online tape library storage system that is flexible and easy to use. Using tape as an alternative storage media as opposed to the magnetic disk has the great potential of cost savings in terms of dollars per megabyte of storage. As this system matures, the Hospital Information Systems

  13. Superconducting tape characterization under flexion

    NASA Astrophysics Data System (ADS)

    Álvarez, A.; Suárez, P.; Cáceres, D.; Pérez, B.; Cordero, E.; Castaño, A.

    2002-08-01

    Electrotechnical applications of high temperature superconducting materials are limited by the difficulty of constructing classical windings with ceramic materials. While Bi-2223 tape may be a solution, it cannot be bent to radii less than a certain value since its superconducting capacity disappears. We describe an automated measurement system of the characteristics of this tape under flexion. It consists of a device that coils the tape over cylinders with different radii. At the same time, the parameters of its superconducting behaviour (e.g. resistance) are taken and processed. This system was developed at the “Benito Mahedero Laboratory of Superconducting Electrical Applications” in the University of Extremadura.

  14. Investigation of the hysteresis losses in CC tapes after laser filamentation

    NASA Astrophysics Data System (ADS)

    Osipov, M.; Splavnik, E.; Pokrovskii, S.; Andreev, A.; Mineev, N.; Abin, D.; Rudnev, I.

    2016-09-01

    Study of AC loss has been conducted on the 4 mm wide CC-tapes manufactured by SuperOx. Filamentation was carried out by laser cutting of the commercially available tapes with a copper coating. Also for comparison, original tapes and commercial multifilament tapes (manufactured by SuperOx by using chemical etching method) were studied. Losses were obtained from the magnetization curves measured on a vibration sample magnetometer in the temperature range from 4 K to 77 K. In addition, the current carrying characteristics of tapes were studied, and the effect of filamentation on the critical current value were examined. We present an analysis of the experimental results, as well as a comparison of data for different types of samples. The possibility of decreasing the energy losses due to filamentation tapes was demonstrated.

  15. Recording and wear characteristics of 4 and 8 mm helical scan tapes

    NASA Technical Reports Server (NTRS)

    Peter, Klaus J.; Speliotis, Dennis E.

    1993-01-01

    Performance data of media on helical scan tape systems (4 and 8 mm) is presented and various types of media are compared. All measurements were performed on a standard MediaLogic model ML4500 Tape Evaluator System with a Flash Converter option for time based measurements. The 8 mm tapes are tested on an Exabyte 8200 drive and 4 mm tapes on an Archive Python drive; in both cases, the head transformer is directly connected to a Media Logic Read/Write circuit and test electronics. The drive functions only as a tape transport and its data recover circuits are not used. Signal to Noise, PW 50, Peak Shift and Wear Test data is used to compare the performance of MP (metal particle), BaFe, and metal evaporate (ME). ME tape is the clear winner in magnetic performance but its susceptibility to wear and corrosion, make it less than ideal for data storage.

  16. New developments for the investigation of hard X-rays emitted by peeling adhesive tapes.

    PubMed

    Krämer, D; Lützenkirchen-Hecht, D; Lühmann, B; Keite-Telgenbüscher, K; Frahm, R

    2013-05-01

    We realized an advanced apparatus for the investigation of emitted X-rays produced by peeling adhesive tape rolls under vacuum conditions. Two stepper motors can unwind and rewind a tape roll, and an additional roller with an optical encoder provides measurement and control of the tape speed. This way reproducible and consecutive experiments are feasible without having to change the tape or break the vacuum. The dependence of the X-ray emission on tape speed, gas pressure, type of adhesive tape, and detector angle has been investigated. The resulting spectra are continuous and span an X-ray energy range of typically 2-60 keV with high intensity. Furthermore, the new apparatus allows the in situ metalization of adhesive tape rolls by a gold sputter source. A significantly increased X-ray emission was observed for adhesive tapes with a metal coating. Thin metal foils have been placed between the tape and the detector, different K- and L-absorption edges could be measured. A considerable enhancement of the emission was achieved under the influence of the magnetic field of an NdFeB permanent magnet. PMID:23742586

  17. String and Sticky Tape Experiments.

    ERIC Educational Resources Information Center

    Edge, R. D., Ed.

    1979-01-01

    Explains how to demonstrate the fundamentals of one dimensional kinematics such as Newton's third law of motion, and collision between bodies, using simple materials of marbles, strings, sticky tape, drinking straws, and rubber bands. (GA)

  18. Canadian Contemporary Issues on Tape

    ERIC Educational Resources Information Center

    Shapter, Jean

    1974-01-01

    Four tapes with interviews with experts in the designated fields comprise the series: a) Canada's Foreign Relations, 1867-1919; b) Canada's Foreign Relations, 1919-1945; c) Canada and China, and d) Canadian Diplomacy and Foreign Policy. (JA)

  19. Casting Of Multilayer Ceramic Tapes

    NASA Technical Reports Server (NTRS)

    Collins, Earl R., Jr.

    1991-01-01

    Procedure for casting thin, multilayer ceramic membranes, commonly called tapes, involves centrifugal casting at accelerations of 1,800 to 2,000 times normal gravitational acceleration. Layers of tape cast one at a time on top of any previous layer or layers. Each layer cast from slurry of ground ceramic suspended in mixture of solvents, binders, and other components. Used in capacitors, fuel cells, and electrolytic separation of oxygen from air.

  20. What's up with duct tape

    SciTech Connect

    Walker, Iain S.; Sherman, Max H.

    2005-03-01

    Recent research suggests that almost any tape can be made to work for a core-to-collar joint when perfectly applied. Given all the better choices available and all the problems that can and do occur in the field, we would not recommend that cloth-backed (natural) rubber-adhesive tapes be used, unless they can pass a suitable E2343 test. If visual degradation is an important factor, Oriented Polypropylene (OPP) and cloth-backed tapes should be avoided. While tapes that fail usually show visual degradation, the converse is not always true. We speculate, however, that visually degraded tapes are more likely to be susceptible to damage from vibration and other mechanical stresses. Conventional nylon straps are quite prone to fail at higher temperatures, but no systematic studies have yet been done across product classes. UL has proposed a new standard for straps, but the protocol for the current UL test does not, however, suggest that it would be a good indicator of durability. Products meeting the new UL standard for straps should be independently tested for the failure modes observed in the field and laboratory to determine if that test is a reasonable indicator of durability. Until a suitable test for strap durability exists, they recommend that only high temperature nylon or metal straps be used--especially in cases where tapes may be sensitive to mechanical stresses.

  1. Tape Storage Optimization at BNL

    NASA Astrophysics Data System (ADS)

    Yu, David; Lauret, Jérôme

    2011-12-01

    The BNL's RHIC and Atlas Computing Facility (RACF), is supporting the RHIC experiment as its Tier0 center and the Atlas/LHC as a Tier1 center. The RACF had to address the issue of efficient access to data stored to disk and tape storage. Randomly restoring files out of tapes destroys access performance to tape by causing too frequently, high latency and time consuming tape mount and dismount. BNL's mass storage system currently holds more than 16 PB of data on tapes, managed by HPSS. To restore files from HPSS, we make use of a scheduler software, called ERADAT. This scheduler system was originally based on a code from OakRidge National Lab, and then it was renamed to BNL Batch at 2005 after some major modifications and enhancements. The new BNL Batch, ERADAT, provides dynamic HPSS resource management, schedule jobs efficiently, enhanced visibility of real-time staging activities and advanced error handling, to maximize the tape staging performance. ERADAT is the interface between HPSS and other applications such as the DataCarousel, our home developed production system and dCache. Scalla/Xrootd MSS can also be interfaced with HPSS via DataCarousel. ERADAT has demonstrated great performance in BNL and other institute.

  2. Anisotropic shrinkage characteristics of tape cast alumina

    NASA Astrophysics Data System (ADS)

    Patwardhan, Jaideep Suresh

    Dimensional control during sintering is a major issue in ceramics processing to avoid high post-sintering costs associated with machining of the fired ceramic part to desired tolerances and dimensions. Ceramic forming processes such as tape casting, injection molding, and extrusion involve shear of anisotropic particles resulting in preferential alignment of the particles in the green body. This preferential alignment causes directionality in mechanical, electrical, optical, and magnetic properties and most importantly warpage or distortion during sintering. A large effort has been devoted to synthesizing ceramic green bodies with minimal density gradients and uniform packing and modeling the sintering behavior evolution but little effort has been devoted to characterizing orientation of particles and the effect of preferential alignment on sintering shrinkage anisotropy. A systematic study was initiated to study the effect of processing variables such as shear rate, solids loading, temperature, and binder content on aqueous tape cast alumina. Three different alumina systems: A16-SG, Baikowski RC-UFX DBM and RC-LS DBM were investigated. Aqueous tapes of high solids loading alumina (56 vol. %) were tape cast at various speeds and thicknesses and assuming plane Couette flow a shear rate regime of 21--270 s-1 was investigated. Higher shear rates and high solids loading resulted in higher in-plane anisotropy whereas the anisotropy in the thickness direction was higher for low solids loading systems. The anisotropy was found to be fairly constant above a certain critical shear rate (˜100 s-1) irrespective of the temperature and the solids loading and this correlated with the viscosity-shear rate relationship of the cast slips. The higher shrinkage anisotropy in the thickness direction for the low solids loading systems (35 and 45 vol. %) was attributed to the higher amount of organics in the slip required to sustain the suitable viscosity for tape casting and

  3. Uniform trapped fields produced by stacks of HTS coated conductor tape

    NASA Astrophysics Data System (ADS)

    Mitchell-Williams, T. B.; Baskys, A.; Hopkins, S. C.; Kalitka, V.; Molodyk, A.; Glowacki, B. A.; Patel, A.

    2016-08-01

    The trapped magnetic field profile of stacks of GdBa2Cu3O7-x superconducting tape was investigated. Angled stacks of superconducting tape were magnetized and found to produce very uniform trapped field profiles. The angled stacks were made of 12 mm × 24 mm solder coated tape pieces and were bonded together following a brief consolidation heat treatment. Layering multiple stacks together and adding a ferromagnetic plate beneath the samples were both found to enhance the magnitude and uniformity of the trapped field profiles. Stationary and time-dependent critical state finite element models were also developed to complement the experimental results and investigate the magnetization process. The size and shapes possible with the angled stacks make them attractive for applications requiring uniform magnetic fields over larger areas than can be achieved with existing bulk rings or tape annuli.

  4. Uniform trapped fields produced by stacks of HTS coated conductor tape

    NASA Astrophysics Data System (ADS)

    Mitchell-Williams, T. B.; Baskys, A.; Hopkins, S. C.; Kalitka, V.; Molodyk, A.; Glowacki, B. A.; Patel, A.

    2016-08-01

    The trapped magnetic field profile of stacks of GdBa2Cu3O7‑x superconducting tape was investigated. Angled stacks of superconducting tape were magnetized and found to produce very uniform trapped field profiles. The angled stacks were made of 12 mm × 24 mm solder coated tape pieces and were bonded together following a brief consolidation heat treatment. Layering multiple stacks together and adding a ferromagnetic plate beneath the samples were both found to enhance the magnitude and uniformity of the trapped field profiles. Stationary and time-dependent critical state finite element models were also developed to complement the experimental results and investigate the magnetization process. The size and shapes possible with the angled stacks make them attractive for applications requiring uniform magnetic fields over larger areas than can be achieved with existing bulk rings or tape annuli.

  5. Design study for multi-channel tape recorder system, volume 1

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The means of storing multispectral, high resolution sensor data on an Earth observing satellite are studied. It is concluded that this is best done digitally on a multi-track, longitudinal, magnetic tape recorder. The machine proposed will store 8 X 10 to the 10th power bits of data on 1040 m of 51 mm-wide magnetic tape mounted on two co-planar reels.

  6. Quick-release medical tape

    PubMed Central

    Laulicht, Bryan; Langer, Robert; Karp, Jeffrey M.

    2012-01-01

    Medical tape that provides secure fixation of life-sustaining and -monitoring devices with quick, easy, damage-free removal represents a longstanding unmet medical need in neonatal care. During removal of current medical tapes, crack propagation occurs at the adhesive–skin interface, which is also the interface responsible for device fixation. By designing quick-release medical tape to undergo crack propagation between the backing and adhesive layers, we decouple removal and device fixation, enabling dual functionality. We created an ordered adhesive/antiadhesive composite intermediary layer between the medical tape backing and adhesive for which we achieve tunable peel removal force, while maintaining high shear adhesion to secure medical devices. We elucidate the relationship between the spatial ordering of adhesive and antiadhesive regions to create a fully tunable system that achieves strong device fixation and quick, easy, damage-free device removal. We also described ways of neutralizing the residual adhesive on the skin and have observed that thick continuous films of adhesive are easier to remove than the thin islands associated with residual adhesive left by current medical tapes. PMID:23112196

  7. Personal miniature electrophysiological tape recorder

    NASA Astrophysics Data System (ADS)

    Green, H.

    1981-11-01

    The use of a personal miniature electrophysiological tape recorder to measure the physiological reactions of space flight personnel to space flight stress and weightlessness is described. The Oxford Instruments Medilog recorder, a battery-powered, four-channel cassette tape recorder with 24 hour endurance is carried on the person and will record EKG, EOG, EEG, and timing and event markers. The data will give information about heart rate and morphology changes, and document adaptation to zero gravity on the part of subjects who, unlike highly trained astronauts, are more representative of the normal population than were the subjects of previous space flight studies.

  8. Personal miniature electrophysiological tape recorder

    NASA Technical Reports Server (NTRS)

    Green, H.

    1981-01-01

    The use of a personal miniature electrophysiological tape recorder to measure the physiological reactions of space flight personnel to space flight stress and weightlessness is described. The Oxford Instruments Medilog recorder, a battery-powered, four-channel cassette tape recorder with 24 hour endurance is carried on the person and will record EKG, EOG, EEG, and timing and event markers. The data will give information about heart rate and morphology changes, and document adaptation to zero gravity on the part of subjects who, unlike highly trained astronauts, are more representative of the normal population than were the subjects of previous space flight studies.

  9. Fully synthetic taped insulation cables

    DOEpatents

    Forsyth, E.B.; Muller, A.C.

    1983-07-15

    The present invention is a cable which, although constructed from inexpensive polyolefin tapes and using typical impregnating oils, furnishes high voltage capability up to 765 kV, and has such excellent dielectric characteristics and heat transfer properties that it is capable of operation at capacities equal to or higher than presently available cables at a given voltage. This is accomplished by using polyethylene, polybutene or polypropylene insulating tape which has been specially processed to attain properties which are not generally found in these materials, but are required for their use in impregnated electrical cables. Chief among these properties is compatibility with impregnating oil.

  10. A Study of Audio Tape: Part II

    ERIC Educational Resources Information Center

    Reen, Noel K.

    1975-01-01

    To evaluate reel audio tape, tests were performed to identify: signal-to-noise ratio, total harmonic distortion, dynamic response, frequency response, biased and virgin tape noise, dropout susceptibility and oxide coating uniformity. (SCC)

  11. Sharpen Your Skills: Tape Recording.

    ERIC Educational Resources Information Center

    Perry, Helen

    1983-01-01

    Three short articles provide tape recording instructions for braille transcribers and teachers of the visually handicapped, for transcribing instructional materials. The first article gives guidelines for transcribing special formats such as typing books. The second article tells how to give verbal instructions for diagraming sentences and other…

  12. A Study of Audio Tape

    ERIC Educational Resources Information Center

    Reen, Noel K.

    1975-01-01

    This is part I of a report on a study comparing reel and cassette tapes for signal-to-noise ration, total harmonic distortion, dynamic response, frequency response, bias and virgin noise and oxide coating uniformity. Test equipment and procedures are described and results are discussed. Charts detail research findings. (CHK)

  13. EROS to universal tape conversion processor

    NASA Technical Reports Server (NTRS)

    Obrien, S. O. (Principal Investigator)

    1980-01-01

    The function of the EROS processor is to allow a user to select a specific area from a full frame LANDSAT image which is written on tape in the EROS format. The area of interest is read from the EROS formatted tape and converted to the JSC Universal format and written onto another tape. This tape can then be read by the IMDACS processing system and normal analysis can be performed.

  14. Calibration of Hall sensor array for critical current measurement of YBCO tape with ferromagnetic substrate

    NASA Astrophysics Data System (ADS)

    Zhu, Yunpeng; Wang, Gang; Liu, Liyuan; Yang, Xinsheng; Zhao, Yong

    2015-12-01

    HAS (Hall sensor array) is a powerful tool to detect the uniformity of HTS (high temperature superconductor) tape through mapping the distribution of remanent or shielding field along the surface of the tape. However, measurement of HTS tape with ferromagnetic parts by HSA is still an issue because the ferromagnetic substrate has influence on the magnetic field around the HTS layer. In this work, a continuous HSA system has been designed to measure the critical current of the YBCO tape with ferromagnetic substrate. The relationship between the remanent field and critical current was calibrated by the finite element method. The result showed that the HSA is an effective method for evaluating the critical current of the HTS tape with ferromagnetic substrate.

  15. Experiments and FE modeling of stress-strain state in ReBCO tape under tensile, torsional and transverse load

    NASA Astrophysics Data System (ADS)

    Ilin, K.; Yagotintsev, K. A.; Zhou, C.; Gao, P.; Kosse, J.; Otten, S. J.; Wessel, W. A. J.; Haugan, T. J.; van der Laan, D. C.; Nijhuis, A.

    2015-05-01

    For high current superconductors in high magnet fields with currents in the order of 50 kA, single ReBCO coated conductors must be assembled in a cable. The geometry of such a cable is mostly such that combined torsion, axial and transverse loading states are anticipated in the tapes and tape joints. The resulting strain distribution, caused by different thermal contraction and electromagnetic forces, will affect the critical current of the tapes. Tape performance when subjected to torsion, tensile and transverse loading is the key to understanding limitations for the composite cable performance. The individual tape material components can be deformed, not only elastically but also plastically under these loads. A set of experimental setups, as well as a convenient and accurate method of stress-strain state modeling based on the finite element method have been developed. Systematic measurements on single ReBCO tapes are carried out combining axial tension and torsion as well as transverse loading. Then the behavior of a single tape subjected to the various applied loads is simulated in the model. This paper presents the results of experimental tests and detailed FE modeling of the 3D stress-strain state in a single ReBCO tape under different loads, taking into account the temperature dependence and the elastic-plastic properties of the tape materials, starting from the initial tape processing conditions during its manufacture up to magnet operating conditions. Furthermore a comparison of the simulations with experiments is presented with special attention for the critical force, the threshold where the tape performance becomes irreversibly degraded. We verified the influence of tape surface profile non-uniformity and copper stabilizer thickness on the critical force. The FE models appear to describe the tape experiments adequately and can thus be used as a solid basis for optimization of various cabling concepts.

  16. Analysis of cache for streaming tape drive

    NASA Astrophysics Data System (ADS)

    Chinnaswamy, V.

    A tape subsystem consists of a controller and a tape drive. Tapes are used for backup, data interchange, and software distribution. The backup operation is addressed. During a backup operation, data is read from disk, processed in CPU, and then sent to tape. The processing speeds of a disk subsystem, CPU, and a tape subsystem are likely to be different. A powerful CPU can read data from a fast disk, process it, and supply the data to the tape subsystem at a faster rate than the tape subsystem can handle. On the other hand, a slow disk drive and a slow CPU may not be able to supply data fast enough to keep a tape drive busy all the time. The backup process may supply data to tape drive in bursts. Each burst may be followed by an idle period. Depending on the nature of the file distribution in the disk, the input stream to the tape subsystem may vary significantly during backup. To compensate for these differences and optimize the utilization of a tape subsystem, a cache or buffer is introduced in the tape controller. Most of the tape drives today are streaming tape drives. A streaming tape drive goes into reposition when there is no data from the controller. Once the drive goes into reposition, the controller can receive data, but it cannot supply data to the tape drive until the drive completes its reposition. A controller can also receive data from the host and send data to the tape drive at the same time. The relationship of cache size, host transfer rate, drive transfer rate, reposition, and ramp up times for optimal performance of the tape subsystem are investigated. Formulas developed will also show the advantages of cache watermarks to increase the streaming time of the tape drive, maximum loss due to insufficient cache, tradeoffs between cache and reposition times and the effectiveness of cache on a streaming tape drive due to idle times or interruptions due in host transfers. Several mathematical formulas are developed to predict the performance of the tape

  17. Analysis of cache for streaming tape drive

    NASA Technical Reports Server (NTRS)

    Chinnaswamy, V.

    1993-01-01

    A tape subsystem consists of a controller and a tape drive. Tapes are used for backup, data interchange, and software distribution. The backup operation is addressed. During a backup operation, data is read from disk, processed in CPU, and then sent to tape. The processing speeds of a disk subsystem, CPU, and a tape subsystem are likely to be different. A powerful CPU can read data from a fast disk, process it, and supply the data to the tape subsystem at a faster rate than the tape subsystem can handle. On the other hand, a slow disk drive and a slow CPU may not be able to supply data fast enough to keep a tape drive busy all the time. The backup process may supply data to tape drive in bursts. Each burst may be followed by an idle period. Depending on the nature of the file distribution in the disk, the input stream to the tape subsystem may vary significantly during backup. To compensate for these differences and optimize the utilization of a tape subsystem, a cache or buffer is introduced in the tape controller. Most of the tape drives today are streaming tape drives. A streaming tape drive goes into reposition when there is no data from the controller. Once the drive goes into reposition, the controller can receive data, but it cannot supply data to the tape drive until the drive completes its reposition. A controller can also receive data from the host and send data to the tape drive at the same time. The relationship of cache size, host transfer rate, drive transfer rate, reposition, and ramp up times for optimal performance of the tape subsystem are investigated. Formulas developed will also show the advantages of cache watermarks to increase the streaming time of the tape drive, maximum loss due to insufficient cache, tradeoffs between cache and reposition times and the effectiveness of cache on a streaming tape drive due to idle times or interruptions due in host transfers. Several mathematical formulas are developed to predict the performance of the tape

  18. Effect of tape recording on perturbation measures.

    PubMed

    Jiang, J; Lin, E; Hanson, D G

    1998-10-01

    Tape recorders have been shown to affect measures of voice perturbation. Few studies, however, have been conducted to quantitatively justify the use or exclusion of certain types of recorders in voice perturbation studies. This study used sinusoidal and triangular waves and synthesized vowels to compare perturbation measures extracted from directly digitized signals with those recorded and played back through various tape recorders, including 3 models of digital audio tape recorders, 2 models of analog audio cassette tape recorders, and 2 models of video tape recorders. Signal contamination for frequency perturbation values was found to be consistently minimal with digital recorders (percent jitter = 0.01%-0.02%), mildly increased with video recorders (0.05%-0.10%), moderately increased with a high-quality analog audio cassette tape recorder (0.15%), and most prominent with a low-quality analog audio cassette tape recorder (0.24%). Recorder effect on amplitude perturbation measures was lowest in digital recorders (percent shimmer = 0.09%-0.20%), mildly to moderately increased in video recorders and a high-quality analog audio cassette tape recorder (0.25%-0.45%), and most prominent in a low-quality analog audio cassette tape recorder (0.98%). The effect of cassette tape material, length of spooled tape, and duration of analysis were also tested and are discussed.

  19. 41 CFR 101-26.508 - Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... processing (EDP) tape and instrumentation tape (wide and intermediate band). 101-26.508 Section 101-26.508... Programs § 101-26.508 Electronic data processing (EDP) tape and instrumentation tape (wide and intermediate band). Procurement by Federal agencies of EDP tape and instrumentation tape (wide and intermediate...

  20. High density tape casting system

    NASA Technical Reports Server (NTRS)

    Collins, Earl R., Jr. (Inventor)

    1989-01-01

    A system is provided for casting thin sheets (or tapes) of particles bound together, that are used for oxygen membranes and other applications, which enables the particles to be cast at a high packing density in a tape of uniform thickness. A slurry contains the particles, a binder, and a solvent, and is cast against the inside walls of a rotating chamber. Prior to spraying the slurry against the chamber walls, a solvent is applied to a container. The solvent evaporates to saturate the chamber with solvent vapor. Only then is the slurry cast. As a result, the slurry remains fluid long enough to spread evenly over the casting surface formed by the chamber, and for the slurry particles to become densely packed. Only then is the chamber vented to remove solvent, so the slurry can dry. The major novel feature is applying solvent vapor to a rotating chamber before casting slurry against the chamber walls.

  1. Electromechanical behaviour of REBCO tape lap splices under transverse compressive loading

    NASA Astrophysics Data System (ADS)

    Grether, A.; Scheuerlein, C.; Ballarino, A.; Bottura, L.

    2016-07-01

    We have studied the influence of transverse compressive stress on the resistance and critical current (I c ) of soldered REBCO tape lap splices. Internal contact resistances dominate the overall REBCO lap splice resistances. Application of transverse compressive stress up to 250 MPa during the resistance measurements does not alter the resistance and I c of the soldered REBCO splices that were studied. The resistance of unsoldered REBCO tape lap splices depends strongly on the contact pressure. At a transverse compressive stress of 100 MPa, to which Roebel cables are typically exposed in high field magnets, the crossover splice contact resistance is comparable to the internal tape resistances.

  2. Critical state solution and alternating current loss computation of polygonally arranged thin superconducting tapes

    NASA Astrophysics Data System (ADS)

    Brambilla, Roberto; Grilli, Francesco; Martini, Luciano

    2013-08-01

    The current density and field distributions in polygonally arranged thin superconducting tapes carrying AC current are derived under the assumption of the critical state model. Starting from the generic Biot-Savart law for a general polygonal geometry, we derive a suitable integral equation for the calculation of the current density and magnetic field in each tape. The model works for any transport current below Ic, which makes it attractive for studying cases of practical interest, particularly the dependence of AC losses on parameters such as the number of tapes, their distance from the center, and their separation.

  3. Tape casting and partial melting of Bi-2212 thick films

    NASA Technical Reports Server (NTRS)

    Buhl, D.; Lang, TH.; Heeb, B.; Gauckler, L. J.

    1995-01-01

    To produce Bi-2212 thick films with high critical current densities tape casting and partial melting is a promising fabrication method. Bi-2212 powder and organic additives were mixed into a slurry and tape casted onto glass by the doctor blade tape casting process. The films were cut from the green tape and partially molten on Ag foils during heat treatment. We obtained almost single-phase and well-textured films over the whole thickness of 20 microns. The orientation of the (a,b)-plane of the grains was parallel to the substrate with a misalignment of less than 6 deg. At 77 K/0T a critical current density of 15, 000 A/sq cm was reached in films of the dimension 1 cm x 2 cm x 20 microns (1 micron V/cm criterion, resistively measured). At 4 K/0T the highest value was 350,000 A/sq cm (1 nV/cm criterion, magnetically measured).

  4. Tape casting and partial melting of Bi-2212 thick films

    SciTech Connect

    Buhl, D.; Lang, T.; Heeb, B.

    1994-12-31

    To produce Bi-2212 thick films with high critical current densities tape casting and partial melting is a promising fabrication method. Bi-2212 powder and organic additives were mixed into a slurry and tape casted onto glass by the doctor blade tape casting process. The films were cut from the green tape and partially molten on Ag foils during heat treatment. We obtained almost single-phase and well-textured films over the whole thickness of 20 {mu}m. The orientation of the (a,b)-plane of the grains were parallel to the substrate with a misalignment of less than 6{degrees}. At 77K/OT a critical current density of 15`000 A/cm{sup 2} was reached in films of the dimension 1cm x 2cm x 20{mu}m (1{mu}V/cm criterion, resistively measured). At 4K/OT the highest value was 350`000 A/cm{sup 2} (1nV/cm criterion, magnetically measured).

  5. LANDSAT-D accelerated payload correction subsystem output computer compatible tape format

    NASA Technical Reports Server (NTRS)

    1982-01-01

    The NASA GSFC LANDSAT-D Ground Segment (GS) is developing an Accelerated Payload Correction Subsystem (APCS) to provide Thematic Mapper (TM) image correction data to be used outside the GS. This correction data is computed from a subset of the TM Payload Correction Data (PCD), which is downlinked from the spacecraft in a 32 Kbps data stream, and mirror scan correction data (MSCD), which is extracted from the wideband video data. This correction data is generated in the GS Thematic Mapper Mission Management Facility (MMF-T), and is recorded on a 9-track 1600 bit per inch computer compatible tape (CCT). This CCT is known as a APCS Output CCT (AOT). The AOT follows standardized corrections with respect to data formats, record construction and record identification. Applicable documents are delineated; common conventions which are used in further defining the structure, format and content of the AOT are defined; and the structure and content of the AOT are described.

  6. TAPECERT- A TAPE CERTIFICATION UTILITY FOR DEC VAX/VMS COMPUTERS

    NASA Technical Reports Server (NTRS)

    Fullner, S. E.

    1994-01-01

    A tape certification program tests the useability of magnetic tape at different densities by writing test patterns and re-reading them. The ability to certify tapes is important in environments that do large amounts of tape processing. TAPECERT is a VAX utility for tape certification in use at the Jet Propulsion Laboratory Multi-Mission Image Processing Laboratory which handles data from projects such as Voyager and Galileo. TAPECERT allows the user to select the tape density, the test pattern to use, the number of allowed retries, and whether to allow extended inter-record gaps to skip past bad spots on the tape. The program displays system error messages (parity errors, for instance) and record count information, with totals every 1000 blocks. TAPECERT is designed such that command procedures can be set up with defaults for different types of certification runs. TAPECERT is written in FORTRAN 77 for interactive execution and has been implemented on a DEC VAX series computer operating under VMS level 3.7 and level 4.2. TAPECERT utilizes standard VMS system services and run-time library routines. This program was developed in 1985.

  7. Tape-recorded Lectures With Slide Synchronization

    ERIC Educational Resources Information Center

    Goodhue, D.

    1969-01-01

    Describes "Taped Explanation Slide Synchronization" programs used for individual study or group showing in college zoology. Discusses preparation of programs, class organization, equipment, and costs. (EB)

  8. FGGE/ERBZ tape specification and shipping letter description

    NASA Technical Reports Server (NTRS)

    Han, D.; Lo, H.

    1983-01-01

    The FGGE/ERBZ tape contains 5 parameters which are extracted and reformatted from the Nimbus-7 ERB Zonal Means Tape. There are three types of files on a FGGE/ERBZ tape: a tape header file, and data files. Physical characteristics, gross format, and file specifications are given. A sample tape check/document printout (shipping letter) is included.

  9. Pocket-size manual tape reader device aids computer tape checking

    NASA Technical Reports Server (NTRS)

    Odle, F. L.

    1967-01-01

    Pocket-size plastic manual tape reader device aids in reading, interpreting, and correcting binary and octal coded punched tapes. The coded information is more easily read if the color of the back plate contrasts sharply with that of the tape.

  10. TReqS: The Tape REQuest Scheduler

    NASA Astrophysics Data System (ADS)

    Schaeffer, Jonathan; Gómez Casanova, Andrés

    2011-12-01

    TReqS is a new layer in the storage infrastructure at CCIN2P3 controlling the read operations for data stored on tapes in HPSS (a HSM) by centralizing all requests. The development and deployment of TReqS at CCIN2P3 has brought major advances in data access services on several aspects. First, by sorting and scheduling tape mounts, we radically reduce the waiting time due to media movements in the tape library. Second, in a mutualised environment where tape drives are globally available to all users, TReqS ensures the fair share of the drives. Finaly, TReqS softens the impact of unpredictable grid jobs and transfers on the actual tape library and efficiently masks the data access complexity to the end user.

  11. Heavy ion irradiation of Bi-2223 silver-clad tapes for superconducting current density enhancement

    SciTech Connect

    Malozcnoff, A.P.; Carter, W.L.; Riley, G.N. Jr.; Wheeler, R. IV; Kirk, M.A.; Civale, L.; Marwick, A.D.

    1993-07-01

    Silver-clad composite tapes of Bi(Pb)SrCaCuO-2223 were irradiated with 1 GeV Au{sup 23+} ions perpendicular to the tape plane, creating columnar tracks with 10 nm diameter. Detailed transmission electron microscopy shows continuous columns, but with variations in the track thickness of +/{minus}2 nm. Magnetic hystersis measurements show substantial enhancement of superconducting current density at most temperatures and fields. Granular and nongranular models for the origin of the magnetic signals are discussed. The results indicate the potential for further performance improvement in high temperature superconducting wire technology, as well as limits in the high-field performance at 77 K.

  12. Mechanical stabilization of BSCCO-2223 superconducting tapes

    SciTech Connect

    King, C.G.; Grey, D.A.; Mantone, A.

    1996-12-31

    A system to provide mechanical stabilization to high temperature BSCCO-2223 superconducting tape by laminating 0.081 mm thick, spring hard, copper foil to both sides with lead-tin eutectic solder has been successfully optimized. This system has been applied as a method to create a strong, windable composite from pure silver BSCCO tapes with a minimum of critical current (I{sub c}) degradation. The {open_quotes}as received{close_quotes} conductor is evaluated for physical consistency of width and thickness over the 3000 meters that were later strengthened, insulated and wound into a demonstration coil. Electrical degradation in the strengthened tape as a result of lamination was found to average 24 percent with a range from 4 to 51 percent. This was less than the degradation that would have occurred in an unstrengthened tape during subsequent insulation and coil winding processes. Additional work was performed to evaluate the mechanical properties of the strengthened tapes. The copper can double the ultimate tensile strength of the pure silver tapes. Additionally, pure silver and dispersion strengthened silver matrix tapes are laminated with 0.025 mm thick copper and 304 stainless steel foil to investigate minimization of the cross sectional area of the strengthening component. The stainless steel can increase the UTS of the pure silver tapes sixfold. Metallography is used to examine the laminate and the conductor. Mechanical properties and critical currents of these tapes are also reported both before and after strengthening. The I{sub c} is also measured as a function of strain on the laminated tapes.

  13. Demonstration project cuts red tape

    NASA Astrophysics Data System (ADS)

    Katzoff, Judith A.

    Results from a demonstration project aimed at cutting red tape in federal grants for basic research at universities are "very encouraging" so far, according to Don I. Phillips, executive director of the Government-University-Industry Research Roundtable. The roundtable is coordinating the experimental effort, with the participation of five major federal agencies as well as the Florida state university system and the University of Miami (a private institution in Coral Gables, Fla.).Under the project, special conditions apply to grants from the participating agencies to individual researchers at the participating universities: Investigators do not have to ask the agency's permission for changes in budget allocations, purchases of permanent equipment, or foreign travel. Grant money can be spent up to a year after the grant ends without a special request. Under this plan, researchers, with agency approval, can also ask to have their entire research program covered as a single administrative entity, rather than as several individual projects.

  14. High-Density-Tape Casting System

    NASA Technical Reports Server (NTRS)

    Collins, Earl R., Jr.

    1987-01-01

    Centrifuge packs solids from slurry into uniform, dense layer. New system produces tapes of nearly theoretical packing density. Centrifugal system used to cast thin tapes for capacitors, fuel cells, and filters. Cylindrical rotary casting chamber mounted on high-speed bearings and connected to motor. Liquid for vapor-pressure control and casting slurry introduced from syringes through rotary seal. During drying step, liquid and vapor vented through feed tubes or other openings. Laminated tapes produced by adding more syringes to cast additional layers of different materials.

  15. Kinesio Taping Fundamentals for the Equine Athlete.

    PubMed

    Molle, Sybille

    2016-04-01

    The Kinesio taping method was developed in Japan for use in humans in 1979. The use of complementary therapies is becoming common in equine athletes and the discovery of Kinesio taping potential brought it into the animal world. Kinesio taping can be used to treat a wide range of clinical conditions, from tendon injuries to neurologic disorders and from muscle contractures to postural insufficiencies. Its use in veterinary medicine is promising, but relies heavily on evidence-based clinical reports. Further scientific research is needed to fully understand the real effectiveness of application. PMID:26898963

  16. Effects of ankle eversion taping using kinesiology tape in a patient with ankle inversion sprain.

    PubMed

    Lee, Sun-Min; Lee, Jung-Hoon

    2016-01-01

    [Purpose] The aim of this study was to report the effects of ankle eversion taping using kinesiology tape on ankle inversion sprain. [Subject] The subject was a 21-year-old woman with Grade 2 ankle inversion sprain. [Methods] Ankle eversion taping was applied to the sprained left ankle using kinesiology tape for 4 weeks (average, 15 h/day). [Results] Ankle instability and pain were reduced, and functional dynamic balance was improved after ankle eversion taping for 4 weeks. The Cumberland Ankle Instability Tool score and reach distances in the Y-Balance and lunge tests were increased. [Conclusion] Repeated ankle eversion taping may be an effective treatment intervention for ankle inversion sprain. PMID:27064668

  17. Ankle inversion taping using kinesiology tape for treating medial ankle sprain in an amateur soccer player

    PubMed Central

    Lee, Sun-Min; Lee, Jung-Hoon

    2015-01-01

    [Purpose] The purpose of this study was to report the effects of ankle inversion taping using kinesiology tape in a patient with a medial ankle sprain. [Subject] A 28-year-old amateur soccer player suffered a Grade 2 medial ankle sprain during a match. [Methods] Ankle inversion taping was applied to the sprained ankle every day for 2 months. [Results] His symptoms were reduced after ankle inversion taping application for 2 months. The self-reported function score, the reach distances in the Star Excursion Balance Test, and the weight-bearing ankle dorsiflexion were increased. [Conclusion] This study showed that ankle inversion taping using kinesiology tape may be an effective therapy for a patient with a medial ankle sprain. PMID:26311991

  18. Effects of ankle eversion taping using kinesiology tape in a patient with ankle inversion sprain

    PubMed Central

    Lee, Sun-Min; Lee, Jung-Hoon

    2016-01-01

    [Purpose] The aim of this study was to report the effects of ankle eversion taping using kinesiology tape on ankle inversion sprain. [Subject] The subject was a 21-year-old woman with Grade 2 ankle inversion sprain. [Methods] Ankle eversion taping was applied to the sprained left ankle using kinesiology tape for 4 weeks (average, 15 h/day). [Results] Ankle instability and pain were reduced, and functional dynamic balance was improved after ankle eversion taping for 4 weeks. The Cumberland Ankle Instability Tool score and reach distances in the Y-Balance and lunge tests were increased. [Conclusion] Repeated ankle eversion taping may be an effective treatment intervention for ankle inversion sprain. PMID:27064668

  19. Ankle inversion taping using kinesiology tape for treating medial ankle sprain in an amateur soccer player.

    PubMed

    Lee, Sun-Min; Lee, Jung-Hoon

    2015-07-01

    [Purpose] The purpose of this study was to report the effects of ankle inversion taping using kinesiology tape in a patient with a medial ankle sprain. [Subject] A 28-year-old amateur soccer player suffered a Grade 2 medial ankle sprain during a match. [Methods] Ankle inversion taping was applied to the sprained ankle every day for 2 months. [Results] His symptoms were reduced after ankle inversion taping application for 2 months. The self-reported function score, the reach distances in the Star Excursion Balance Test, and the weight-bearing ankle dorsiflexion were increased. [Conclusion] This study showed that ankle inversion taping using kinesiology tape may be an effective therapy for a patient with a medial ankle sprain.

  20. Effects of ankle eversion taping using kinesiology tape in a patient with ankle inversion sprain.

    PubMed

    Lee, Sun-Min; Lee, Jung-Hoon

    2016-01-01

    [Purpose] The aim of this study was to report the effects of ankle eversion taping using kinesiology tape on ankle inversion sprain. [Subject] The subject was a 21-year-old woman with Grade 2 ankle inversion sprain. [Methods] Ankle eversion taping was applied to the sprained left ankle using kinesiology tape for 4 weeks (average, 15 h/day). [Results] Ankle instability and pain were reduced, and functional dynamic balance was improved after ankle eversion taping for 4 weeks. The Cumberland Ankle Instability Tool score and reach distances in the Y-Balance and lunge tests were increased. [Conclusion] Repeated ankle eversion taping may be an effective treatment intervention for ankle inversion sprain.

  1. Note: Effective anvil size for transverse delamination test of rare-earth-Ba₂Cu₃Oy coated conductor tapes.

    PubMed

    Shin, Hyung-Seop; Gorospe, Alking B; Dedicatoria, Marlon J

    2015-10-01

    In coated conductor (CC) tapes used in magnet and coil applications, delamination due to excessive transverse tensile stresses is still one of the major issues that need considerations. Recently, several methods in evaluating the delamination strength of CC tapes are being used. In the case of anvil test, size of the anvils will be an important factor considering its applications (i.e., superconducting coil impregnation). In this study, delamination strength of CC tape was examined using different upper anvil sizes and their effects were discussed. Finally, reasonable sizes of upper anvil to be used were proposed considering the application conditions. PMID:26521009

  2. Tape Cassette Bacteria Detection System

    NASA Technical Reports Server (NTRS)

    1973-01-01

    The design, fabrication, and testing of an automatic bacteria detection system with a zero-g capability and based on the filter-capsule approach is described. This system is intended for monitoring the sterility of regenerated water in a spacecraft. The principle of detection is based on measuring the increase in chemiluminescence produced by the action of bacterial porphyrins (i.e., catalase, cytochromes, etc.) on a luminol-hydrogen peroxide mixture. Since viable as well as nonviable organisms initiate this luminescence, viable organisms are detected by comparing the signal of an incubated water sample with an unincubated control. Higher signals for the former indicate the presence of viable organisms. System features include disposable sealed sterile capsules, each containing a filter membrane, for processing discrete water samples and a tape transport for moving these capsules through a processing sequence which involves sample concentration, nutrient addition, incubation, a 4 Molar Urea wash and reaction with luminol-hydrogen peroxide in front of a photomultiplier tube. Liquids are introduced by means of a syringe needle which pierces a rubber septum contained in the wall of the capsule. Detection thresholds obtained with this unit towards E. coli and S. marcescens assuming a 400 ml water sample are indicated.

  3. Video Tape and the Mentally Retarded

    ERIC Educational Resources Information Center

    Weisbord, H. F.

    1972-01-01

    Three uses of video tape recordings with the mentally retarded; discussed briefly are staff training or teacher education, parental involvement in the child's education, and therapeutic uses by psychiatrists and psychologists. (CB)

  4. Carbon nanotube-based synthetic gecko tapes.

    PubMed

    Ge, Liehui; Sethi, Sunny; Ci, Lijie; Ajayan, Pulickel M; Dhinojwala, Ali

    2007-06-26

    We have developed a synthetic gecko tape by transferring micropatterned carbon nanotube arrays onto flexible polymer tape based on the hierarchical structure found on the foot of a gecko lizard. The gecko tape can support a shear stress (36 N/cm(2)) nearly four times higher than the gecko foot and sticks to a variety of surfaces, including Teflon. Both the micrometer-size setae (replicated by nanotube bundles) and nanometer-size spatulas (individual nanotubes) are necessary to achieve macroscopic shear adhesion and to translate the weak van der Waals interactions into high shear forces. We have demonstrated for the first time a macroscopic flexible patch that can be used repeatedly with peeling and adhesive properties better than the natural gecko foot. The carbon nanotube-based tape offers an excellent synthetic option as a dry conductive reversible adhesive in microelectronics, robotics, and space applications.

  5. Light-Curing Adhesive Repair Tapes

    NASA Technical Reports Server (NTRS)

    Allred, Ronald; Haight, Andrea Hoyt

    2009-01-01

    Adhesive tapes, the adhesive resins of which can be cured (and thereby rigidized) by exposure to ultraviolet and/or visible light, are being developed as repair patch materials. The tapes, including their resin components, consist entirely of solid, low-outgassing, nonhazardous or minimally hazardous materials. They can be used in air or in vacuum and can be cured rapidly, even at temperatures as low as -20 C. Although these tapes were originally intended for use in repairing structures in outer space, they can also be used on Earth for quickly repairing a wide variety of structures. They can be expected to be especially useful in situations in which it is necessary to rigidize tapes after wrapping them around or pressing them onto the parts to be repaired.

  6. User's guide and tape specification for ERB 7 DELMAT

    NASA Technical Reports Server (NTRS)

    Ardanuy, P.; Penn, L.

    1985-01-01

    Guidance is provided to the DELMAT user in the areas of purpose, use and limitations of DELMAT tapes and software. The DELMAT tape specifications is also provided. The ERB-7, ERB MAT and tape characteristics applicable to the DELMAT tapes are also summarized.

  7. Educational Uses of Cartridge Tapes. Dissemination Document No. 11.

    ERIC Educational Resources Information Center

    Levine, S. Joseph

    Tape cartridges for use by special education teachers are analyzed according to design, effective use, and availability. Basic operating principles of cassette and continuous loop tape cartridges are described and illustrated. Advantages of tape cartridges are indicated, such as the following: the position is saved on tape during student timeouts,…

  8. Effects of ankle balance taping with kinesiology tape for a patient with chronic ankle instability

    PubMed Central

    Kim, Byeong-Jo; Lee, Jung-Hoon; Kim, Chang-Tae; Lee, Sun-Min

    2015-01-01

    [Purpose] To report the effects of ankle balance taping for a patient with chronic ankle instability (CAI). [Subject] A 33-year-old man with a 10 year history of chronic ankle stability. [Methods] ABT with kinesiology tape was performed for 2 months (average, 16 h/day) around the right ankle. [Results] At the end of two months, no ankle instability was noted when ascending and descending the stairs, jumping, turning, operating the pedals while driving, and lifting heavy objects. [Conclusion] The repeated use of kinesiology tape in ankle balance taping may be an effective treatment for recovering the ankle stability of patients with chronic ankle instability. PMID:26311206

  9. Effects of ankle balance taping with kinesiology tape for a patient with chronic ankle instability.

    PubMed

    Kim, Byeong-Jo; Lee, Jung-Hoon; Kim, Chang-Tae; Lee, Sun-Min

    2015-07-01

    [Purpose] To report the effects of ankle balance taping for a patient with chronic ankle instability (CAI). [Subject] A 33-year-old man with a 10 year history of chronic ankle stability. [Methods] ABT with kinesiology tape was performed for 2 months (average, 16 h/day) around the right ankle. [Results] At the end of two months, no ankle instability was noted when ascending and descending the stairs, jumping, turning, operating the pedals while driving, and lifting heavy objects. [Conclusion] The repeated use of kinesiology tape in ankle balance taping may be an effective treatment for recovering the ankle stability of patients with chronic ankle instability.

  10. Getting a charge out of transparent tape

    NASA Astrophysics Data System (ADS)

    Harrington, Randal

    2000-01-01

    When two pieces of transparent tape are placed on top of each other (sticky side to nonsticky side) and then separated, it is observed that one piece becomes negatively charged and the other positively charged. The sign of the charge on each piece depends on the brand of tape used. This phenomenon is frequently used to investigate the properties of charge and charged objects in introductory physics courses.

  11. Aligned Carbon Nanotube Tape for Sensor Applications

    NASA Technical Reports Server (NTRS)

    Tucker, Dennis S.

    2013-01-01

    For this effort, will concentrate on three applications: Vibration Gyroscope utilizes piezoelectric properties of the tape and Coriolis effect Accelerometer utilizes the piezoresistive property Strain Gauge utilizes piezoresistive property Accelerometer and Strain Gauge can also utilize piezoelectric effect Test piezoelectric properties using facilities at the Microfabrication Laboratory (AMRDEC) . Enhance piezoelectric effect using polyvinylidine fluoride and P(VDF ]TrFE) which is readily polarizable .Spray matrix solution while winding fiber; Sandwich of CNT tape and PVDF film (DOE .Two Level) . Construct and test prototype vibration gyroscope . Construct and test prototype accelerometer using cantilever design . Test strain sensitivity of CNT tape against industrial strain gauge . Embed CNT tape in composite samples as well as on surface and test to failure (4 ]point bend) A piezoelectric device exhibits an electrical response from a mechanical applied stress. . A piezoelectric device has both capacitance and resistance properties in which by applying an electric field from a waveform will exert a mechanical stress that can be monitored for a response. . The typical waveform applied is a sinusoidal waveform of a defined voltage for a defined period. The defined voltage is driven from 0 volts to the positive defined volts then back to 0 and driven to negative defined volts then back to 0. . Example. Vmax set to 10V and period set to 10 ms. . Voltage will start at zero, go to 10 volts, return to zero, go to ]10 volts and return to zero during 10 ms. . Applying this electrical field to a DUT, the capacitance response and resistance response can be observed. CNT tape is easier to manufacture and cheaper than micromachining silicon or other ceramic piezoelectric used in gyroscopes and accelerometers CNT tape properties can be modified during manufacture for specific application CNT tape has enhanced mechanical and thermal properties in addition to unique electrical

  12. FGGE/ERBM tape specification and shipping letter description

    NASA Technical Reports Server (NTRS)

    Han, D.; Lo, H.

    1983-01-01

    The Nimbus-7 FGGE/ERBM tape contains 27 ERB parameters which are extracted and reformatted from the Nimbus-7 ERB-MATRIX tape. There are four types of files on a FGGE/ERBM tape: a test file; tape-header file which describes the data set characteristics and the contents of the tape; a grid-descriptor file which contains the information of the ERB scanning channel target number and their associated latitude limits and longitude intervals; and one or more data files. A single end-of-file (EOF) tape mark is written after each file, and two EOF marks are written after the last data file on the tape.

  13. ORRC/SAIL interface control document for SAIL OFT data tapes, revision A

    NASA Technical Reports Server (NTRS)

    1979-01-01

    The formats for all orbital flight tests magnetic tape recordings produced in the Johnson Space Center Shuttle Avionics Laboratories which are required to be processed in the orbiter data reduction complex or by the mission control center network interference processor are described.

  14. Rating underground pipeline tape and shrink sleeve coating systems

    SciTech Connect

    Norsworthy, R.

    1999-11-01

    A rating system was developed for several coating types used for underground pipeline systems. Consideration included soil stress, adhesion, surface preparation, cathodic protection (CP) shielding, CP requirements, handling and construction, repair, field joint system, bends and other components, and the application process. Polyethylene- and polyvinyl chloride-backed tapes, woven polyolefin geotextile fabric (WGF)-backed tapes, hot-applied tapes, petrolatum- and wax-based tapes, and shrink sleeves were evaluated. WGF-backed tapes had the highest rating.

  15. Strategy for robot motion and path planning in robot taping

    NASA Astrophysics Data System (ADS)

    Yuan, Qilong; Chen, I.-Ming; Lembono, Teguh Santoso; Landén, Simon Nelson; Malmgren, Victor

    2016-06-01

    Covering objects with masking tapes is a common process for surface protection in processes like spray painting, plasma spraying, shot peening, etc. Manual taping is tedious and takes a lot of effort of the workers. The taping process is a special process which requires correct surface covering strategy and proper attachment of the masking tape for an efficient surface protection. We have introduced an automatic robot taping system consisting of a robot manipulator, a rotating platform, a 3D scanner and specially designed taping end-effectors. This paper mainly talks about the surface covering strategies for different classes of geometries. The methods and corresponding taping tools are introduced for taping of following classes of surfaces: Cylindrical/extended surfaces, freeform surfaces with no grooves, surfaces with grooves, and rotational symmetrical surfaces. A collision avoidance algorithm is introduced for the robot taping manipulation. With further improvements on segmenting surfaces of taping parts and tape cutting mechanisms, such taping solution with the taping tool and the taping methodology can be combined as a very useful and practical taping package to assist humans in this tedious and time costly work.

  16. Method for Determining Local Current Density in 2G HTS Tapes

    NASA Astrophysics Data System (ADS)

    Bludova, A. I.

    Practically important problem is to determine the density and direction of 2G HTS induced currents at each point on the tape in order to examine its local deviations. This problem is resolved indirectly by spatial measurement of generated magnetic field with a scanning Hall sensor at a given height above the tape surface. Current density is subsequently determined by the Biot-Savart law inversion in Fourier domain. Tikhonov regularization is used in order to increase precision. Method is verified with the model current density reconstruction. Optimal calculation parameters and resulting precision are described.

  17. Krytox Lubrication Tape Study. [fluorinated lubricating oil for video tape recorders

    NASA Technical Reports Server (NTRS)

    Lee, F.

    1978-01-01

    The use of Krytox, a fluorinated oil, as a tape surface lubricant was studied for a wideband video tape recorder. In spite of the 5 to 1 head wear reduction credited to the surface lubricant, the resultant head life fell short of the 1500 hour goal.

  18. Effects of kinesio tape compared with non-elastic tape on hand grip strength

    PubMed Central

    Kim, Ji Young; Kim, Seong Yeol

    2016-01-01

    [Purpose] Many assumptions have been made about taping and several studies have considered tape application methods; however, the true effect of taping on muscle strength remains unclear. Most previous studies compared application techniques using Kinesio tape (KT), but studies that compared muscle strength using non-elastic tape (NT) are limited. Moreover, no studies have applied KT and NT in the same way to assess grip strength in normal subjects. The purpose of this study was to evaluate the immediate effect of application of two tapes with different elastic properties on maximal grip strength in healthy adults. [Subjects and Methods] Twenty healthy adults were divided into two groups (KT and NT). Maximal grip strength was measured with a dynamometer. Forearm extensor muscles of the dominant hand were then taped and subjects were immediately asked to perform hand grip movement with maximum strength in the same standardized manner. [Results] In the KT group, maximal grip strength was significantly increased compared to the initial value; however, in the NT group, there was no significant difference in maximal grip strength. [Conclusion] This study suggests that only Kinesio tape can increase maximal grip strength immediately after application on the extensor region of the forearm. PMID:27313372

  19. Effects of kinesio tape compared with non-elastic tape on hand grip strength.

    PubMed

    Kim, Ji Young; Kim, Seong Yeol

    2016-05-01

    [Purpose] Many assumptions have been made about taping and several studies have considered tape application methods; however, the true effect of taping on muscle strength remains unclear. Most previous studies compared application techniques using Kinesio tape (KT), but studies that compared muscle strength using non-elastic tape (NT) are limited. Moreover, no studies have applied KT and NT in the same way to assess grip strength in normal subjects. The purpose of this study was to evaluate the immediate effect of application of two tapes with different elastic properties on maximal grip strength in healthy adults. [Subjects and Methods] Twenty healthy adults were divided into two groups (KT and NT). Maximal grip strength was measured with a dynamometer. Forearm extensor muscles of the dominant hand were then taped and subjects were immediately asked to perform hand grip movement with maximum strength in the same standardized manner. [Results] In the KT group, maximal grip strength was significantly increased compared to the initial value; however, in the NT group, there was no significant difference in maximal grip strength. [Conclusion] This study suggests that only Kinesio tape can increase maximal grip strength immediately after application on the extensor region of the forearm.

  20. Bi-2212/Ag tape conductor and coil development

    SciTech Connect

    Albert, G.W.; Leung, E.M.; Zhou, R.; Salazar, K.V.

    1996-12-31

    This paper presents recent progress by Los Alamos National Laboratory/Superconductivity Technology Center (LANL/STC) and Lockheed Martin Corporation/Advanced Development Operations (LMQADO) Energy and Power Systems group to jointly develop and test high temperature superconductor coils for practical applications such as motors, generators, magnetic bearings, superconducting magnetic energy storage (SMES), MAGLEV trains, or electrical inductors. Critical currents of 105 A/cm{sup 2} have been achieved in a Bi-2212/Ag tape conductor using a patented Ag addition process to improve core morphology and uniformity. Results of testing to measure key conductor parameters are presented along with design and analysis details of a general-purpose multi-layer HTS coil.

  1. Enhanced quench propagation in 2G-HTS coils co-wound with stainless steel or anodised aluminium tapes

    NASA Astrophysics Data System (ADS)

    Núñez-Chico, A. B.; Martínez, E.; Angurel, L. A.; Navarro, R.

    2016-08-01

    Early quench detection and thermal stability of superconducting coils are of great relevance for practical applications. Magnets made with second generation high temperature superconducting (2G-HTS) tapes present low quench propagation velocities and therefore slow voltage development and high local temperature rises, which may cause irreversible damage. Since quench propagation depends on the anisotropy of the thermal conductivity, this may be used to achieve an improvement of the thermal stability and robustness of 2G-HTS coils. On pancake type coils, the thermal conductivity along the tapes (coil’s azimuthal direction) is mostly fixed by the 2G-HTS tape characteristics, so that the reduction of anisotropy relies on the improvement of the radial thermal conductivity, which depends on the used materials between superconducting tapes, as well as on the winding and impregnation processes. In this contribution, we have explored two possibilities for such anisotropy reduction: by using anodised aluminium or stainless steel tapes co-wound with the 2G-HTS tapes. For all the analysed coils, critical current distribution, minimum quench energy values and both tangential and radial quench propagation velocities at different temperatures and currents are reported and compared with the results of similar coils co-wound with polyimide (Kapton®) tapes.

  2. Ubiquitous Graphene Electronics on Scotch Tape.

    PubMed

    Chung, Yoonyoung; Kim, Hyun Ho; Lee, Sangryun; Lee, Eunho; Won Kim, Seong; Ryu, Seunghwa; Cho, Kilwon

    2015-01-01

    We report a novel concept of graphene transistors on Scotch tape for use in ubiquitous electronic systems. Unlike common plastic substrates such as polyimide and polyethylene terephthalate, the Scotch tape substrate is easily attached onto various objects such as banknotes, curved surfaces, and human skin, which implies potential applications wherein electronics can be placed in any desired position. Furthermore, the soft Scotch tape serves as an attractive substrate for flexible/foldable electronics that can be significantly bent, or even crumpled. We found that the adhesive layer of the tape with a relatively low shear modulus relaxes the strain when subjected to bending. The capacitance of the gate dielectric made of oxidized aluminum oxide was 1.5 μF cm(-2), so that a supply voltage of only 2.5 V was sufficient to operate the devices. As-fabricated graphene transistors on Scotch tape exhibited high electron mobility of 1326 (±155) cm(2) V(-1) s(-1); the transistors still showed high mobility of 1254 (±478) cm(2) V(-1) s(-1) even after they were crumpled. PMID:26220874

  3. Ubiquitous Graphene Electronics on Scotch Tape

    NASA Astrophysics Data System (ADS)

    Chung, Yoonyoung; Ho Kim, Hyun; Lee, Sangryun; Lee, Eunho; Won Kim, Seong; Ryu, Seunghwa; Cho, Kilwon

    2015-07-01

    We report a novel concept of graphene transistors on Scotch tape for use in ubiquitous electronic systems. Unlike common plastic substrates such as polyimide and polyethylene terephthalate, the Scotch tape substrate is easily attached onto various objects such as banknotes, curved surfaces, and human skin, which implies potential applications wherein electronics can be placed in any desired position. Furthermore, the soft Scotch tape serves as an attractive substrate for flexible/foldable electronics that can be significantly bent, or even crumpled. We found that the adhesive layer of the tape with a relatively low shear modulus relaxes the strain when subjected to bending. The capacitance of the gate dielectric made of oxidized aluminum oxide was 1.5 μF cm-2, so that a supply voltage of only 2.5 V was sufficient to operate the devices. As-fabricated graphene transistors on Scotch tape exhibited high electron mobility of 1326 (±155) cm2 V-1 s-1 the transistors still showed high mobility of 1254 (±478) cm2 V-1 s-1 even after they were crumpled.

  4. Ubiquitous Graphene Electronics on Scotch Tape

    PubMed Central

    Chung, Yoonyoung; Ho Kim, Hyun; Lee, Sangryun; Lee, Eunho; Won Kim, Seong; Ryu, Seunghwa; Cho, Kilwon

    2015-01-01

    We report a novel concept of graphene transistors on Scotch tape for use in ubiquitous electronic systems. Unlike common plastic substrates such as polyimide and polyethylene terephthalate, the Scotch tape substrate is easily attached onto various objects such as banknotes, curved surfaces, and human skin, which implies potential applications wherein electronics can be placed in any desired position. Furthermore, the soft Scotch tape serves as an attractive substrate for flexible/foldable electronics that can be significantly bent, or even crumpled. We found that the adhesive layer of the tape with a relatively low shear modulus relaxes the strain when subjected to bending. The capacitance of the gate dielectric made of oxidized aluminum oxide was 1.5 μF cm−2, so that a supply voltage of only 2.5 V was sufficient to operate the devices. As-fabricated graphene transistors on Scotch tape exhibited high electron mobility of 1326 (±155) cm2 V−1 s−1; the transistors still showed high mobility of 1254 (±478) cm2 V−1 s−1 even after they were crumpled. PMID:26220874

  5. Texture and properties of epitaxial substrates for second-generation tape superconductors

    NASA Astrophysics Data System (ADS)

    Rodionov, D. P.; Gervas'eva, I. V.; Khlebnikova, Yu. V.

    2015-12-01

    Data on the degree of cube texture perfection, magnetic, and strength properties of two groups of alloys, namely, nickel- and copper-based compositions are reported. For all the alloys under study, a certain quantitative ratio of principal texture components in the alloys subjected to cold rolling to 98.6-99.0% degree of deformation was shown to be a criterion for the possibility of preparing a sharp cube texture in tapes in the course of subsequent recrystallizing annealing. Optimum compositions of nickel-based alloys, which are nonmagnetic at a working temperature of superconductor, were found; all copper-based alloys are nonmagnetic at this temperature. The strength properties of recrystallized nickel- and copper-based tapes are substantially higher than those of tapes made of pure metals.

  6. Experiment attributes to establish tube with twisted tape insert performance cooling plasma facing components

    DOE PAGES

    Clark, Emily; Ramirez, Emilio; Ruggles, Art E.; Griffard, Cory

    2015-08-18

    The modeling capability for tubes with twisted tape inserts is reviewed with reference to the application of cooling plasma facing components in magnetic confinement fusion devices. The history of experiments examining the cooling performance of tubes with twisted tape inserts is reviewed with emphasis on the manner of heating, flow stability limits and the details of the test section and fluid delivery system. Models for heat transfer, burnout, and onset of net vapor generation in straight tube flows and tube with twisted tape are compared. As a result, the gaps in knowledge required to establish performance limits of the plasmamore » facing components are identified and attributes of an experiment to close those gaps are presented.« less

  7. Experiment attributes to establish tube with twisted tape insert performance cooling plasma facing components

    SciTech Connect

    Clark, Emily; Ramirez, Emilio; Ruggles, Art E.; Griffard, Cory

    2015-08-18

    The modeling capability for tubes with twisted tape inserts is reviewed with reference to the application of cooling plasma facing components in magnetic confinement fusion devices. The history of experiments examining the cooling performance of tubes with twisted tape inserts is reviewed with emphasis on the manner of heating, flow stability limits and the details of the test section and fluid delivery system. Models for heat transfer, burnout, and onset of net vapor generation in straight tube flows and tube with twisted tape are compared. As a result, the gaps in knowledge required to establish performance limits of the plasma facing components are identified and attributes of an experiment to close those gaps are presented.

  8. Apparent anisotropy effects of upper critical field in high- textured superconducting Nb-Ti tapes

    NASA Astrophysics Data System (ADS)

    Guryev, V. V.; Shavkin, S. V.; Kruglov, V. S.; Volkov, P. V.; Vasiliev, A. L.; Ovcharov, A. V.; Likhachev, I. A.; Pashaev, E. M.; Svetogorov, R. D.; Zubavichus, Y. V.

    2016-09-01

    Analysis of the voltage-field characteristics of superconducting niobium-titanium tapes is the objective of this work. We used both the original cold-rolled and heat-treated tapes, whose structure and texture we had studied in detail. We observed anisotropy in the upper critical field and the reduction of the transition width with increasing angle between the plane of tape and the direction of the magnetic field. In addition, we have registered a significant difference of the upper critical field values, obtained from the voltage-field characteristics and field dependence of the pinning force. Considering our results, we suggest an explanation of the observed features within the macro-inhomogeneity model.

  9. Cluster filtering/control of bending/torsional vibrations of a tape tether using smart-film sensors/actuators

    NASA Astrophysics Data System (ADS)

    Kojima, Hirohisa; Kunugi, Kouta; Trivailo, Pavel M.

    2016-06-01

    Tape tethers show great promise for application in space debris removal because they possess a large collecting area, which is crucial for the collection of electrons from a plasma environment in space. Tape tethers are therefore preferred over string tethers in electrodynamic tethered systems (EDTS), which operate based on the Lorentz force derived from the interaction between the electric current on the tether and the Earth's magnetic field. Vibrations of the tether may disturb the attitude of the mother satellite and the subsatellite, and are difficult to damp in space because the damping would be minimal owing to the almost zero drag force in space. Due to their relatively large width, tape tethers experience torsional deformation and therefore cannot be treated as a string tether. If torsional deformation of tape tethers is not avoided, the advantage of tape tethers as the materials for EDT systems will be deteriorated. Point-type sensors and actuators are usually used to sense and control vibrations. However, it is difficult to apply such sensors and actuators to tape tethers because of the substantial length of the tether as well as the need for a deployment mechanism, such as a reel. In order to overcome the difficulties related to vibrations, the use of smart-film sensors and actuators for sensing and controlling vibrations of tape tethers is considered in this study. In a previous study, we presented an application of smart film for sensing vibrations of tape tethers, but the actuation of tape tethers using smart-film actuators has not yet been reported. In the present paper, we mathematically derive suitable configurations of smart-film attachment to a tape tether for cluster filtering and actuation of bending and torsional vibrations of the tape tether, and carried out cluster actuation experiments. The experimental results reveal that the bending and torsional vibrations of a tape tether can be reduced by cluster actuation control based on direct

  10. Digital optical tape: Technology and standardization issues

    NASA Technical Reports Server (NTRS)

    Podio, Fernando L.

    1996-01-01

    During the coming years, digital data storage technologies will continue an aggressive growth to satisfy the user's need for higher storage capacities, higher data transfer rates and long-term archival media properties. Digital optical tape is a promising technology to satisfy these user's needs. As any emerging data storage technology, the industry faces many technological and standardization challenges. The technological challenges are great, but feasible to overcome. Although it is too early to consider formal industry standards, the optical tape industry has decided to work together by initiating prestandardization efforts that may lead in the future to formal voluntary industry standards. This paper will discuss current industry optical tape drive developments and the types of standards that will be required for the technology. The status of current industry prestandardization efforts will also be discussed.

  11. Catalog of the Oak Ridge National Laboratory Meteorological Tape Library

    SciTech Connect

    Bell, M.A.

    1983-08-01

    This report gives a complete inventory of the data tapes in the ORNL Meteorological Tape Library (OMTL). The attributes of each tape, including location of the weather station (city and state), station number, standard data format, dates covered, data set name(s), and job control language considerations (record format, record length, blocksize, tape label, and tape density), are listed for each tape. In addition, a description of some of the special characteristics of each of the available standard meteorological data formats is presented.

  12. Accuracy testing of steel and electric groundwater-level measuring tapes: Test method and in-service tape accuracy

    USGS Publications Warehouse

    Fulford, Janice M.; Clayton, Christopher S.

    2015-10-09

    The calibration device and proposed method were used to calibrate a sample of in-service USGS steel and electric groundwater tapes. The sample of in-service groundwater steel tapes were in relatively good condition. All steel tapes, except one, were accurate to ±0.01 ft per 100 ft over their entire length. One steel tape, which had obvious damage in the first hundred feet, was marginally outside the accuracy of ±0.01 ft per 100 ft by 0.001 ft. The sample of in-service groundwater-level electric tapes were in a range of conditions—from like new, with cosmetic damage, to nonfunctional. The in-service electric tapes did not meet the USGS accuracy recommendation of ±0.01 ft. In-service electric tapes, except for the nonfunctional tape, were accurate to about ±0.03 ft per 100 ft. A comparison of new with in-service electric tapes found that steel-core electric tapes maintained their length and accuracy better than electric tapes without a steel core. The in-service steel tapes could be used as is and achieve USGS accuracy recommendations for groundwater-level measurements. The in-service electric tapes require tape corrections to achieve USGS accuracy recommendations for groundwater-level measurement.

  13. Accuracy testing of steel and electric groundwater-level measuring tapes: Test method and in-service tape accuracy

    USGS Publications Warehouse

    Fulford, Janice M.; Clayton, Christopher S.

    2015-01-01

    The calibration device and proposed method were used to calibrate a sample of in-service USGS steel and electric groundwater tapes. The sample of in-service groundwater steel tapes were in relatively good condition. All steel tapes, except one, were accurate to ±0.01 ft per 100 ft over their entire length. One steel tape, which had obvious damage in the first hundred feet, was marginally outside the accuracy of ±0.01 ft per 100 ft by 0.001 ft. The sample of in-service groundwater-level electric tapes were in a range of conditions—from like new, with cosmetic damage, to nonfunctional. The in-service electric tapes did not meet the USGS accuracy recommendation of ±0.01 ft. In-service electric tapes, except for the nonfunctional tape, were accurate to about ±0.03 ft per 100 ft. A comparison of new with in-service electric tapes found that steel-core electric tapes maintained their length and accuracy better than electric tapes without a steel core. The in-service steel tapes could be used as is and achieve USGS accuracy recommendations for groundwater-level measurements. The in-service electric tapes require tape corrections to achieve USGS accuracy recommendations for groundwater-level measurement.

  14. Effects of Kinesio taping and Mcconnell taping on balance and walking speed of hemiplegia patients

    PubMed Central

    Choi, Yong-Kyu; Park, Young-Han; Lee, Jung-Ho

    2016-01-01

    [Purpose] The aim of this study was to evaluate the overlap effect of the PNF following the application of Kinesio taping and the McConnell taping, and also the impact of the taping application method on the balance and walking speed of the patients with stroke. [Subjects and Methods] Thirty-six patients who were diagnosed with hemiplegia due to stroke were selected as subjects of this study. They were randomly and evenly divided into experiment group 1 (Kinesio taping group), experiment group 2 (McConnell taping group), and the control group; each group had 12 patients. [Results] The Berg balance scale (BBS) was used to evaluate balance, and the ability in this study. A 10 m walking test (10MWT) was performed to measure the walking speed. Experiment group 1 showed a statistically significant improvement in balance and walking speed compared to experiment group 2, and the control group in week 4 and week 8. [Conclusion] Application of Kinesio taping had a more beneficial effect on the balance and walking speed than joint-fixation taping of the patients with stroke. PMID:27190448

  15. Textured substrate tape and devices thereof

    DOEpatents

    Goyal, Amit

    2006-08-08

    A method for forming a sharply biaxially textured substrate, such as a single crystal substrate, includes the steps of providing a deformed metal substrate, followed by heating above the secondary recrystallization temperature of the deformed substrate, and controlling the secondary recrystallization texture by either using thermal gradients and/or seeding. The seed is selected to shave a stable texture below a predetermined temperature. The sharply biaxially textured substrate can be formed as a tape having a length of 1 km, or more. Epitaxial articles can be formed from the tapes to include an epitaxial electromagnetically active layer. The electromagnetically active layer can be a superconducting layer.

  16. Tape-Drop Transient Model for In-Situ Automated Tape Placement of Thermoplastic Composites

    NASA Technical Reports Server (NTRS)

    Costen, Robert C.; Marchello, Joseph M.

    1998-01-01

    Composite parts of nonuniform thickness can be fabricated by in-situ automated tape placement (ATP) if the tape can be started and stopped at interior points of the part instead of always at its edges. This technique is termed start/stop-on-the-part, or, alternatively, tape-add/tape-drop. The resulting thermal transients need to be managed in order to achieve net shape and maintain uniform interlaminar weld strength and crystallinity. Starting-on-the-part has been treated previously. This paper continues the study with a thermal analysis of stopping-on-the-part. The thermal source is switched off when the trailing end of the tape enters the nip region of the laydown/consolidation head. The thermal transient is determined by a Fourier-Laplace transform solution of the two-dimensional, time-dependent thermal transport equation. This solution requires that the Peclet number Pe (the dimensionless ratio of inertial to diffusive heat transport) be independent of time and much greater than 1. Plotted isotherms show that the trailing tape-end cools more rapidly than the downstream portions of tape. This cooling can weaken the bond near the tape end; however the length of the affected region is found to be less than 2 mm. To achieve net shape, the consolidation head must continue to move after cut-off until the temperature on the weld interface decreases to the glass transition temperature. The time and elapsed distance for this condition to occur are computed for the Langley ATP robot applying PEEK/carbon fiber composite tape and for two upgrades in robot performance. The elapsed distance after cut-off ranges from about 1 mm for the present robot to about 1 cm for the second upgrade.

  17. Elastic therapeutic tape: do they have the same material properties?

    PubMed Central

    Boonkerd, Chuanpis; Limroongreungrat, Weerawat

    2016-01-01

    [Purpose] Elastic therapeutic tape has been widely used for rehabilitation and treatment of sports injuries. Tapes with different elastic properties serve different treatment purposes with inappropriate tension reducing tape effectiveness. Many tapes are available in the market, but studies on tape properties are limited. The aim of this study was to examine the material properties of elastic therapeutic tape. [Subjects and Methods] Brands of elastic therapeutic tape included KinesioTex®, ATex, Mueller, 3M, and ThaiTape. The Material Testing System Insight® 1 Electromechanical Testing Systems was used to apply a tensile force on elastic therapeutic tape. Ten specimens of each brand were tested. Stress, load, and Young’s modulus at 25%, 50%, 75%, 100%, and maximum point were collected. One-way analysis of variance with post hoc testing was used to analyze tape parameters. [Results] Maximum elongation and Young’s modulus at all percentages were significantly different between brands. There were no differences in maximum load and maximum stress. [Conclusion] Mechanical properties are different for commercial elastic therapeutic tapes. Physiotherapists and other clinicians should be aware of mechanical tape properties to correctly apply kinesio tape. PMID:27190472

  18. Elastic therapeutic tape: do they have the same material properties?

    PubMed

    Boonkerd, Chuanpis; Limroongreungrat, Weerawat

    2016-04-01

    [Purpose] Elastic therapeutic tape has been widely used for rehabilitation and treatment of sports injuries. Tapes with different elastic properties serve different treatment purposes with inappropriate tension reducing tape effectiveness. Many tapes are available in the market, but studies on tape properties are limited. The aim of this study was to examine the material properties of elastic therapeutic tape. [Subjects and Methods] Brands of elastic therapeutic tape included KinesioTex(®), ATex, Mueller, 3M, and ThaiTape. The Material Testing System Insight(®) 1 Electromechanical Testing Systems was used to apply a tensile force on elastic therapeutic tape. Ten specimens of each brand were tested. Stress, load, and Young's modulus at 25%, 50%, 75%, 100%, and maximum point were collected. One-way analysis of variance with post hoc testing was used to analyze tape parameters. [Results] Maximum elongation and Young's modulus at all percentages were significantly different between brands. There were no differences in maximum load and maximum stress. [Conclusion] Mechanical properties are different for commercial elastic therapeutic tapes. Physiotherapists and other clinicians should be aware of mechanical tape properties to correctly apply kinesio tape.

  19. FGGE/SMMR-30 tape specification and shipping letter description

    NASA Technical Reports Server (NTRS)

    Han, D.; Lo, H.

    1983-01-01

    The Nimbus-7 FGGE/SMMR-30 tape which contains sea ice concentration data in 30 km resolution which are extracted and reformatted from Nimbus-7 SMMR PARM-30 tapes in accordance with the FGGE level II International Exchange Format Specification is outlined. There are three types of files on a FGGE/SMMR-30 tape. The first file on the tape is a test file. The second file on the tape is a tape header file. The remaining one or more files are data files. All files are terminated with a single end of file (EOP) tape mark. The last file is terminated with two EOF tape marks. All files are made up of one or more physical records. Each physical record contains 2960 bytes. Each data file contains all available values for a 6 hour synoptic time period.

  20. Tape It Yourself: Videotapes for Teacher Education

    ERIC Educational Resources Information Center

    Ebsworth, Miriam Eistein; Feknous, Barbara; Loyet, Dianne; Zimmerman, Spencer

    2004-01-01

    This paper describes the development and implementation of a series of videotapes of ESL classes for a pre-service teacher education program grounded in experiential learning theory. The videos included footage of ESL classrooms, and tapes edited and supplemented with interviews of ESL teachers. Our experience demonstrates that-with relatively low…

  1. Idea Bank: Duct Tape Note Twister

    ERIC Educational Resources Information Center

    McHenry, Molly

    2008-01-01

    In this article, the author relates how she observed a middle school math teacher deliver a miserable class. She realized that she did the same thing to her music students. To engage her students, she developed "Note Twister," a music reading game using duct tape to form musical notes and the basic premise behind the game, "Twister." She finds…

  2. "Space slitter" for film or tape

    NASA Technical Reports Server (NTRS)

    Johnson, W. H.

    1978-01-01

    Device cuts film or tape into strips by guiding film in channel under cutting blades. Device is operated by lifting pressure bar to insert blades into film. Film is then pulled through blades. Cutter has potential uses in advertising, commercial art, and publishing fields.

  3. Carbon Nanotube-Based Synthetic Gecko Tapes

    NASA Astrophysics Data System (ADS)

    Dhinojwala, Ali

    2008-03-01

    Wall-climbing geckos have unique ability to attach to different surfaces without the use of any viscoelastic glues. On coming in contact with any surface, the micron-size gecko foot-hairs deform, enabling molecular contact over large areas, thus translating weak van der Waals (vdW) interactions into enormous shear forces. We will present our recent results on the development of synthetic gecko tape using aligned carbon nanotubes to mimic the keratin hairs found on gecko feet. The patterned carbon nanotube-based gecko tape can support a shear stress (36 N/cm^2) nearly four times higher than the gecko foot and sticks to a variety of surfaces, including Teflon. Both the micron-size setae (replicated by nanotube bundles) and nanometer-size spatulas (individual nanotubes) are necessary to achieve macroscopic shear adhesion and to translate the weak vdW interactions into high shear forces. The carbon nanotube based tape offers an excellent synthetic option as a dry conductive reversible adhesive in microelectronics, robotics and space applications. The mechanism behind these large shear forces and self-cleaning properties of these carbon nanotube based synthetic gecko tapes will be discussed. This work was performed in collaboration with graduate students Liehui Ge, and Sunny Sethi, and collaborators from RPI; Lijie Ci and Professor Pulickel Ajayan.

  4. Analysis of particulates on tape lift samples

    NASA Astrophysics Data System (ADS)

    Moision, Robert M.; Chaney, John A.; Panetta, Chris J.; Liu, De-Ling

    2014-09-01

    Particle counts on tape lift samples taken from a hardware surface exceeded threshold requirements in six successive tests despite repeated cleaning of the surface. Subsequent analysis of the particle size distributions of the failed tests revealed that the handling and processing of the tape lift samples may have played a role in the test failures. In order to explore plausible causes for the observed size distribution anomalies, scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX), and time-of-flight secondary ion mass spectrometry (ToF-SIMS) were employed to perform chemical analysis on collected particulates. SEM/EDX identified Na and S containing particles on the hardware samples in a size range identified as being responsible for the test failures. ToF-SIMS was employed to further examine the Na and S containing particulates and identified the molecular signature of sodium alkylbenzene sulfonates, a common surfactant used in industrial detergent. The root cause investigation suggests that the tape lift test failures originated from detergent residue left behind on the glass slides used to mount and transport the tape following sampling and not from the hardware surface.

  5. Tape Lessons to Accompany Intermediate Nepali Reader.

    ERIC Educational Resources Information Center

    Verma, Manindra K.

    These tape lessons follow the sequence of the intermediate Nepali Reader. There are 12 lessons each containing various types of exercises designed to increase listening, speaking, and reading skills. Each lesson contains the following types of exercises: (1) listening comprehension; (2) question answering; (3) repetition; and (4) multiple choice…

  6. Distanced Data: Transcribing Other People's Research Tapes

    ERIC Educational Resources Information Center

    Tilley, Susan A.; Powick, Kelly D.

    2004-01-01

    In this article, we report on our qualitative study involving eight individuals hired to transcribe research tapes in university contexts. We consider issues of data analysis and data trustworthiness and the implications for both when transcription is assigned to someone other than the researcher. We explore the challenges transcribers faced…

  7. Multiprocessor system for Holter tape analysis (ECG)

    SciTech Connect

    Feldman, C.L.; Hubelbank, M.; Valvo, V.; Lane, B.

    1983-01-01

    Although techniques for recording and analyzing longterm ambulatory ECGS have been in existence for more than 20 years, the clinical usefulness and frequency of application of the technique continue to grow at an extraordinary rate. To meet the need for faster, more efficient processing of Holter tapes and the growing requirement that the analysis of the tape be quantitatively accurate, a new Holter analysis system has been developed. This system is built around two LSI11 microprocessors and a special purpose byte processor which incorporates an AMD 2903 bit slice chip. It includes 30 MB of mass storage and an impact printer with alphanumeric and graphic capabilities. In a test which included 55 separate readings of 34 12- or 24-hour tapes, correlations with hand counts of vpbs was greater than .99. The system processes either cassette or reel-to-reel tapes at 120* with simultaneous print/process capabilities, has a variety of user interactive displays to assure continuous operator validation, is remarkably nonfatiguing to operate, and automatically produces reports with tables, graphs, and sample ECG strips. 8 references.

  8. A Tape-Lecture Course in Electrochemistry.

    ERIC Educational Resources Information Center

    Sheridan, P.

    1978-01-01

    Investigates the possibility of using audio-tapes for self-study courses in technical colleges. This article presents: (1) description of the electrochemistry course taught; (2) results of the assessment of student reaction to the course; and (3) conclusions. (HM)

  9. Heat reflecting tape for thermoelectric converter

    DOEpatents

    Purdy, David L.

    1977-01-01

    Threads are interlaced with thermoelectric wires to provide a woven cloth in tape form, there being an intermediate layer of heat radiation reflecting material (e.g., aluminum foil) insulated electrically from said wires, which are of opposite thermoelectric polarity and connected as a plurality of thermocouples.

  10. Inconsistencies in tape read and tape write programs on the I-100 image analysis system

    NASA Technical Reports Server (NTRS)

    Hocutt, W. T. (Principal Investigator)

    1978-01-01

    The author has identified the following significant results. The tape read and write programs currently available on the 1-100 perform their intended functions of reading and writing tapes, but are difficult to use because they contain a number of inconsistencies. These inconsistencies can often be overcome by the use of work-around procedures and by trial and error, which is an inefficient use of expensive computer systems that should not be necessary.

  11. Tester automatically checks paper tape punch and reader after maintenance

    NASA Technical Reports Server (NTRS)

    Mazer, L.; Mc Murchy, D. D.

    1967-01-01

    Device automatically bench tests paper tape punches and readers in a simulated operating environment following routine maintenance. The reader and punch operate back-to-back and the paper tape output feeds the reader. The tape leader is prepunched with an arbitrary pattern that is continuously reproduced during the check.

  12. Full tape thickness feature conductors for EMI structures

    DOEpatents

    Peterson, Kenneth A.; Knudson, Richard T.; Smith, Frank R.; Barner, Gregory

    2014-06-10

    Generally annular full tape thickness conductors are formed in single or multiple tape layers, and then stacked to produce an annular solid conductive wall for enclosing an electromagnetic isolation cavity. The conductors may be formed using punch and fill operations, or by flowing conductor-containing material onto the tape edge surfaces that define the interior sidewalls of the cavity.

  13. STS-102 Mission Highlight Resource Tape, Tape 1 of 4. Part A

    NASA Technical Reports Server (NTRS)

    2001-01-01

    This video gives an overview of the first four flight days of the STS-102 mission through a compilation of footage from each day. The crew of STS-102 (Commander James Wetherbee, Pilot James Kelly, and Mission Specialists Andrew Thomas and Paul Richards) and the Expedition 2 crew (Commander Yuriy Usachev and Flight Engineers James Voss and Susan Helms) are seen during the ceremonial breakfast, suitup, and as they board Discovery. The orbiter's launch is seen from several different viewpoints, and various in-flight activities are shown, such as the opening of Discovery's payload bay doors, Helms preparing for the 'H-Reflex Experiment: Effects of Microgravity on the Spine', the rendezvous and docking of Discovery with the International Space Station (ISS), and Helms and Voss preparing for and performing their spacewalks. The crew of STS-102 and both Expedition crews (E1 crew William Shepherd, Yuri Gidzenko, and Sergei Krikalev) are seen in the Destiny Laboratory Module. Activities for flight day five can be seen on 'STS-102 Mission Highlight Resource Tape, Part 1 of 2, Tape 2 of 2' (internal ID 2001096941). Flight days 6-14 activities can be seen on 'STS-102 Mission Highlight Resource Tape, Part 2 of 2, Tape 1 of 2' (internal ID 2001096943) and 'STS-102 Mission Highlight Resource Tape, Part 2 of 2, Tape 2 of 2' (internal ID 2001096940).

  14. Paint and tape: collection and storage of microtraces of paint in adhesive tape.

    PubMed

    Bernhard, W R

    2000-11-01

    The collection and preservation of microtrace evidence with the aid of an adhesive tape is a method of choice in forensic science. This technique is rapid and easy and allows the concentration of microtraces on a carrier, which facilitates further investigations in the laboratory. Adhesive tapes are currently used to secure microtraces of fibers and glass, but hardly for traces of automotive paint and other lacquers for fear of interference with the analysis of binders. A collection of automotive paint consisting of original and repair lacquers collected by tape has been evaluated. After various times of storage within the tape, these samples were compared with untreated references by microscope FT-IR and microspectrophotometry (MSP). Another set of paints was collected in 1984, stored within the tape until 1995, and examined the same way. About 170 layers of lacquer with various types of binder were examined. With the exception of one clear lacquer no difference between treated samples and references was detected. This small difference observed could be correlated to the exposure to xylene (extractant) and was not caused by the storage within the adhesive tape. PMID:11110189

  15. Obituary: Gerald Frederick Tape, 1915-2005

    NASA Astrophysics Data System (ADS)

    Hughes, Robert E.

    2007-12-01

    magnets at BNL and the Very Large Array (VLA) at NRAO. Research output was first-class at both institutions. The NRAO was steadily drawing more young astronomers into a field that was just beginning to show its promise and its indispensability. Jerry took a great interest in the development of the VLA and interacted closely with David Heeschen, the Observatory Director, and with Jack Lancaster, the Project Director. In the middle of the decade, he helped them to steer through some rough waters created by Congressional criticisms that threatened the program. He cooperated closely with NSF and obtained the necessary support to defuse the threat. His last official act for AUI and NRAO was to preside over the grand opening celebration at the site of the VLA. It was on the last day of his presidency, October l, 1980. Jerry Tape clearly led an exemplary life when traced through the series of successful enterprises that marked his rise to ever increasing responsibilities and contributions. But the full measure of a man is also revealed in the way he filled the smaller but unrestricted periods of time that become available to him. Jerry was first and foremost a family man and was constant in his attention and devotion to this call. The AUI trustees recognized the importance of public service and encouraged his participation in worthwhile causes as long as they did not interfere with his primary duties. The AUI staff was small but dedicated and ably maintained timely and effective communication with him in his absence. Thus, Jerry found the time to contribute to issues and organizations that were of importance in his life. Through the last part of the sixties, Jerry served for six years as the United States Representative to the International Atomic Energy Agency (IAEA) with the rank of Ambassador. It was a demanding role, not only because of the frequent trips to the Vienna headquarters, but also because there were continuous official requirements for reports and documentation. A

  16. Laser-plasma interactions from thin tapes for high-energy electron accelerators and seeding compact FELs

    NASA Astrophysics Data System (ADS)

    Shaw, Brian Henry

    This thesis comprises a detailed investigation of the physics of using a plasma mirror (PM) from a tape by reflecting ultrashort pulses from a laser-triggered surface plasma. The tapes used in the characterization of the PM are VHS and computer data storage tape. The tapes are 6.6 m (computer storage tape) and 15 m (VHS) thick. Each tape is 0.5 inches wide, and 10s of meters of tape are spooled using a tape drive; providing thousands of shots on a single reel of tape. The amount of reflected energy of the PM was studied for different input intensities. The fluence was varied by translating the focus of the laser upstream and downstream of the tape, which changed the spot size on the tape surface and hence changed the fluence. This study measured reflectances from both sides of the two tapes, and for input light of both s and p-polarizations. Lastly, an analytic model was developed to understand the reflectance as a function of fluence for each tape material and polarization. Another application that benefits from the advancements of LPA technology is an LPAbased FEL. By sending a high quality electron bunch through an undulator (a periodic structure of positive and negative magnetic poles), the electrons oscillate transversely to the propagation axis and produce radiation. The 1.5 m THUNDER undulator at the BELLA Center has been commissioned using electron beams of 400MeV beams with broad energy spread (35%). To produce a coherent LPA-based FEL, the beam quality would need to improve to sub-percent level energy spread. A seed source could be used to help induce bunching of the electron beam within the undulator. This thesis described the experimental investigation of the physics of using solid-based surface high-harmonic generation (SHHG) from a thin tape as a possible seed source for an FEL. A thin tape placed within centimeters of the undulator's entrance could act as a harmonic generating source, while simultaneously transmitting an electron beam. This removes

  17. Strongly enhanced vortex pinning from 4 to 77 K in magnetic fields up to 31 T in 15 mol.% Zr-added (Gd, Y)-Ba-Cu-O superconducting tapes

    SciTech Connect

    Xu, A; Delgado, L; Khatri, N; Liu, Y; Selvamanickam, V; Abraimov, D; Jaroszynski, J; Kametani, F; Larbalestier, DC

    2014-04-01

    Applications of REBCO coated conductors are now being developed for a very wide range of temperatures and magnetic fields and it is not yet clear whether vortex pinning strategies aimed for high temperature, low field operation are equally valid at lower temperatures and higher fields. A detailed characterization of the superconducting properties of a 15 mol.% Zr-added REBCO thin film made by metal organic chemical vapor deposition, from 4.2 to 77 K under magnetic fields up to 31 T is presented in this article. Even at a such high level of Zr addition, T-c depression has been avoided (T-c = 91 K), while at the same time an exceptionally high irreversibility field H-irr approximate to 14.8 T at 77 K and a remarkably high vortex pinning force density F-p approximate to 1.7 TN/m(3) at 4.2 K have been achieved. We ascribe the excellent pinning performance at high temperatures to the high density (equivalent vortex matching field similar to 7 T) of self-assembled BZO nanorods, while the low temperature pinning force is enhanced by large additional pinning which we ascribe to strain-induced point defects induced in the REBCO matrix by the BZO nanorods. Our results suggest even more room for further performance enhancement of commercial REBCO coated conductors and point the way to REBCO coil applications at liquid nitrogen temperatures since the critical current density J(c)(H//c) characteristic at 77 K are now almost identical to those of fully optimized Nb-Ti at 4 K. (C) 2014 Author(s).

  18. Pressure Roller For Tape-Lift Tests

    NASA Technical Reports Server (NTRS)

    Abrams, Eve

    1991-01-01

    Rolling device applies nearly constant, uniform pressure to surface. Simple tool exerts nearly constant pressure via compression of sheath by fixed amount. Pins hold wheels on cylinder and cylinder on tangs of handle. Cylinder and handle made of metal or plastic. Sheath press-fit or glued to cylinder. End pins attached to cylinder by adhesive or screw threads. Device intended for use in taking tape-lift samples of particulate contamination on surface.

  19. Measuring Earth's Magnetic Field Simply.

    ERIC Educational Resources Information Center

    Stewart, Gay B.

    2000-01-01

    Describes a method for measuring the earth's magnetic field using an empty toilet paper tube, copper wire, clear tape, a battery, a linear variable resistor, a small compass, cardboard, a protractor, and an ammeter. (WRM)

  20. STS-111 Mission Highlights Resource Tape

    NASA Astrophysics Data System (ADS)

    2002-08-01

    This video, Part 2 of 4, shows the activities of the STS-111 crew (Kenneth Cockrell, Commander; Paul Lockhart, Pilot; Franklin Chang-Diaz, Phillipe Perrin, Mission Specialists) during flight days 5 through 7. Also shown are the incoming Expedition 5 (Valeri Korzun, Commander; Peggy Whitson, NASA ISS Science Officer; Sergei Treschev, Flight Engineer) and outgoing Expedition 4 (Yuri Onufriyenko, Commander; Carl Walz, Daniel Bursch, Flight Engineers) crews of the ISS (International Space Station). The activities from other flight days can be seen on 'STS-111 Mission Highlights Resource Tape' Part 1 of 4 (internal ID 2002139357), 'STS-111 Mission Highlights Resource Tape' Part 3 of 4 (internal ID 2002139468), and 'STS-111 Mission Highlights Resource Tape' Part 4 of 4 (internal ID 2002139474). On flight day 5, the transfer and installation of a Power and Data Grapple Fixture onto the P6 Truss during an EVA (extravehicular activity) is shown. The relocation of micrometeorite debris shields is also shown. Canadarm 2 is used to move the Mobile Base System near the Mobile Transporter on the ISS Destiny Module. The capture of the Mobile Base System takes place on flight day 6, along with a crew transfer ceremony on board the ISS. The video includes a view of the South Pacific just before dawn, and the Endeavour crew answers questions from the public.

  1. Software Computes Tape-Casting Parameters

    NASA Technical Reports Server (NTRS)

    deGroh, Henry C., III

    2003-01-01

    Tcast2 is a FORTRAN computer program that accelerates the setup of a process in which a slurry containing metal particles and a polymeric binder is cast, to a thickness regulated by a doctor blade, onto fibers wound on a rotating drum to make a green precursor of a metal-matrix/fiber composite tape. Before Tcast2, setup parameters were determined by trial and error in time-consuming multiple iterations of the process. In Tcast2, the fiber architecture in the final composite is expressed in terms of the lateral distance between fibers and the thickness-wise distance between fibers in adjacent plies. The lateral distance is controlled via the manner of winding. The interply spacing is controlled via the characteristics of the slurry and the doctor-blade height. When a new combination of fibers and slurry is first cast and dried to a green tape, the shrinkage from the wet to the green condition and a few other key parameters of the green tape are measured. These parameters are provided as input to Tcast2, which uses them to compute the doctor-blade height and fiber spacings needed to obtain the desired fiber architecture and fiber volume fraction in the final composite.

  2. Transaction aware tape-infrastructure monitoring

    NASA Astrophysics Data System (ADS)

    Nikolaidis, Fotios; Kruse, Daniele Francesco

    2014-06-01

    Administrating a large scale, multi protocol, hierarchical tape infrastructure like the CERN Advanced STORage manager (CASTOR)[2], which stores now 100 PB (with an increasing step of 25 PB per year), requires an adequate monitoring system for quick spotting of malfunctions, easier debugging and on demand report generation. The main challenges for such system are: to cope with CASTOR's log format diversity and its information scattered among several log files, the need for long term information archival, the strict reliability requirements and the group based GUI visualization. For this purpose, we have designed, developed and deployed a centralized system consisting of four independent layers: the Log Transfer layer for collecting log lines from all tape servers to a single aggregation server, the Data Mining layer for combining log data into transaction context, the Storage layer for archiving the resulting transactions and finally the Web UI layer for accessing the information. Having flexibility, extensibility and maintainability in mind, each layer is designed to work as a message broker for the next layer, providing a clean and generic interface while ensuring consistency, redundancy and ultimately fault tolerance. This system unifies information previously dispersed over several monitoring tools into a single user interface, using Splunk, which also allows us to provide information visualization based on access control lists (ACL). Since its deployment, it has been successfully used by CASTOR tape operators for quick overview of transactions, performance evaluation, malfunction detection and from managers for report generation.

  3. STS-109 Mission Highlights Resource Tape

    NASA Astrophysics Data System (ADS)

    2002-05-01

    This video, Part 3 of 4, shows the activities of the STS-109 crew (Scott Altman, Commander; Duane Carey, Pilot; John Grunsfeld, Payload Commander; Nancy Currie, James Newman, Richard Linnehan, Michael Massimino, Mission Specialists) during flight days 6 and 7. The activities from other flight days can be seen on 'STS-109 Mission Highlights Resource Tape' Part 1 of 4 (internal ID 2002139471), 'STS-109 Mission Highlights Resource Tape' Part 2 of 4 (internal ID 2002137664), and 'STS-109 Mission Highlights Resource Tape' Part 4 of 4 (internal ID 2002137577). Flight day 6 features a very complicated EVA (extravehicular activity) to service the HST (Hubble Space Telescope). Astronauts Grunsfeld and Linnehan replace the HST's power control unit, disconnecting and reconnecting 36 tiny connectors. The procedure includes the HST's first ever power down. The cleanup of spilled water from the coollant system in Grunsfeld's suit is shown. The pistol grip tool, and two other space tools are also shown. On flight day 7, Newman and Massimino conduct an EVA. They replace the HST's FOC (Faint Object Camera) with the ACS (Advanced Camera for Surveys). The video ends with crew members playing in the shuttle's cabin with a model of the HST.

  4. Field theory of a traveling wave tube amplifier with tape helix

    SciTech Connect

    Freund, H.P.; Vanderplaats, N.R.; Kodis, M.A.

    1993-12-01

    A self-consistent relativistic field theory of a helix traveling wave tube (TWT) is presented for a configuration in which a magnetized pencil beam propagates through a tape helix enclosed with a loss-free wall. A linear analysis of the interaction is solved subject to the boundary conditions imposed by the beam, helix, and wall. The wave equation for the fields within the electron beam corresponds to the Appleton-Hartree magneto ionic wave modes that are of mixed electrostatic/electromagnetic polarization. Hence, the determinantal dispersion equation that is obtained implicitly includes beam space-charge effects without recourse to a heuristic model of the space-charge field. This dispersion equation includes azimuthal variations and all spatial harmonics of the tape helix. Solutions are found numerically, which correspond to both the extraordinary (X) and ordinary (O) solutions for the Appleton-Hartree modes. Note that the O- and X-mode designations are more properly applied for waves propagating perpendicular to the ambient magnetic field in a uniform plasma. In the present case, the authors are interested in the modes propagating parallel to the ambient magnetic field in a bounded system in which an electron beam is enclosed by a tape helix and a conducting wall.

  5. Low thermal conductive Bi-2223 tapes sheathed with Ag-Au alloys

    SciTech Connect

    Fujishiro, Hiroyuki; Ikebe, Manabu; Noto, Koshichi; Matsukawa, Michiaki,; Sasaoka, Takaaki; Nomura, Katsumi; Sato, Junichi; Kuma, Shoji,

    1994-07-01

    With the view of applying to power current leads for superconducting magnet systems and for other cryogenic power handling systems, low thermal conductive Bi-2223 superconducting tapes sheathed with Ag-Au alloy were measured from 12 to 260K. The critical current density (overall-J) was about 1,700A/cm{sup 2} at 77K, 0T and remained nearly constant irrespective of Au concentration up to 11 at %. The tape sheathed with Ag + 11at.% Au alloy, of which the superconductor cross-section ratio f{sub sc} was 0.65, had a thermal conductivity value about 0.2W/cmK at 77K. This value is as low as that of Cu-Zu. It was found that the thermal conductivity of the tape was close to the calculated one based on f{sub sc} and the independently measured thermal conductivities of the Ag-Au alloy and the Bi-2223 superconductor. The superconducting tapes sheathed with the alloy were confirmed to be suitable for the application as power current leads.

  6. High critical currents in heavily doped (Gd,Y)Ba2Cu3Ox superconductor tapes

    SciTech Connect

    Selvamanickam, V; Gharahcheshmeh, MH; Xu, A; Galstyan, E; Delgado, L; Cantoni, C

    2015-01-19

    REBa2Cu3Ox ((REBCO), RE = rare earth) superconductor tapes with moderate levels of dopants have been optimized for high critical current density in low magnetic fields at 77 K, but they do not exhibit exemplary performance in conditions of interest for practical applications, i.e., temperatures less than 50K and fields of 2-30 T. Heavy doping of REBCO tapes has been avoided by researchers thus far due to deterioration in properties. Here, we report achievement of critical current densities (J(c)) above 20 MA/cm(2) at 30 K, 3 T in heavily doped (25 mol.% Zr-added) (Gd,Y)Ba2Cu3Ox superconductor tapes, which is more than three times higher than the J(c) typically obtained in moderately doped tapes. Pinning force levels above 1000 GN/m(3) have also been attained at 20 K. A composition map of lift factor in J(c) (ratio of J(c) at 30 K, 3 T to the J(c) at 77 K, 0 T) has been developed which reveals the optimum film composition to obtain lift factors above six, which is thrice the typical value. A highly c-axis aligned BaZrO3 (BZO) nanocolumn defect density of nearly 7 x 10(11) cm(-2) as well as 2-3 nm sized particles rich in Cu and Zr have been found in the high J(c) films. (C) 2015 AIP Publishing LLC.

  7. High critical currents in heavily doped (Gd,Y)Ba2Cu3Ox superconductor tapes

    DOE PAGES

    Selvamanickam, V.; Gharahcheshmeh, M. Heydari; Xu, A.; Galstyan, E.; Delgado, L.; Cantoni, C.

    2015-01-20

    REBa2Cu3Ox superconductor tapes with moderate levels of dopants have been optimized for high critical current density in low magnetic fields at 77 K, but they do not exhibit exemplary performance in conditions of interest for practical applications, i.e., temperatures less than 50 K and fields of 2–30 T. Heavy doping of REBCO tapes has been avoided by researchers thus far due to deterioration in properties. Here, we report achievement of critical current densities (Jc) above 20 MA/cm2 at 30 K, 3 T in heavily doped (25 mol. % Zr-added) (Gd,Y)Ba2Cu3Ox superconductor tapes, which is more than three times higher thanmore » the Jc typically obtained in moderately doped tapes. Pinning force levels above 1000 GN/m3 have also been attained at 20 K. A composition map of lift factor in Jc (ratio of Jc at 30 K, 3 T to the Jc at 77 K, 0 T) has been developed which reveals the optimum film composition to obtain lift factors above six, which is thrice the typical value. A highly c-axis aligned BaZrO3 (BZO) nanocolumn defect density of nearly 7 × 1011 cm–2 as well as 2–3nm sized particles rich in Cu and Zr have been found in the high Jc films.« less

  8. Kinesio-Taping Application and Corticospinal Excitability at the Ankle Joint

    PubMed Central

    Tremblay, Francois; Karam, Siobhan

    2015-01-01

    Context Physiotherapists and athletic trainers often use Kinesio Taping (KT) to prevent and treat musculoskeletal injuries in athletes, yet evidence about its effects on neuromuscular performance is conflicting. Objective To investigate the influence of a KT application directed at the ankle joint on measures of corticospinal excitability with transcranial magnetic stimulation. Design Controlled laboratory study. Setting Research laboratory. Patients or Other Participants Twelve healthy young women (age = 23.1 ± 1.9 years; range, 19–26 years). Intervention(s) Participants were tested under no-tape and KT conditions according to a random sequence order. The KT was applied to the skin overlying the dorsiflexor and plantar-flexor muscles of the ankle. Main Outcome Measure(s) We assessed changes in the amplitude of motor-evoked potentials elicited at rest and during movement and changes in the silent period and background muscle activity during movement. Results Taping conditions had no effect on motor-evoked potential amplitude at rest or during movement or on the silent-period duration and background muscle activity. Conclusions Our results concur with other recent reports, showing KT applications have little influence at the neuromuscular level. Alterations in sensory feedback ascribed to elastic taping are likely insufficient to modulate corticospinal excitability in a functionally meaningful manner. PMID:26090708

  9. Superconducting Nb3Ge for high-field magnets

    NASA Technical Reports Server (NTRS)

    Braginski, A. I.; Daniel, M. R.; Roland, C. W.; Woollam, J. A.

    1978-01-01

    Superconducting Nb3Ge tape conductors 5 to 10 m long were fabricated by chemical vapor deposition. Such tapes could be used in high-field magnet applications. Average tape properties set the upper performance limit of a magnet at 17 teslas (4.2 K). Highest critical-current densities obtained in thin and layered films set the upper performance limit at 20 teslas (4.2 K).

  10. Effects of Kinesio Taping versus McConnell Taping for Patellofemoral Pain Syndrome: A Systematic Review and Meta-Analysis.

    PubMed

    Chang, Wen-Dien; Chen, Fu-Chen; Lee, Chia-Lun; Lin, Hung-Yu; Lai, Ping-Tung

    2015-01-01

    Objectives. To conduct a systematic review comparing the effects of Kinesio taping with McConnell taping as a method of conservative management of patients with patellofemoral pain syndrome (PFPS). Methods. MEDLINE, PUBMED, EMBASE, AMED, and the Cochrane Central Register of Control Trials electronic databases were searched through July 2014. Controlled studies evaluating the effects of Kinesio or McConnell taping in PFPS patients were retrieved. Results. Ninety-one articles were selected from the articles that were retrieved from the databases, and 11 articles were included in the analysis. The methods, evaluations, and results of the articles were collected, and the outcomes of patellar tapings were analyzed. Kinesio taping can reduce pain and increase the muscular flexibility of PFPS patients, and McConnell taping also had effect in pain relief and patellar alignment. Meta-analysis showed small effect in pain reduction and motor function improvement and moderate effect in muscle activity change among PFPS patients using Kinesio taping. Conclusions. Kinesio taping technique used for muscles can relieve pain but cannot change patellar alignment, unlike McConnell taping. Both patellar tapings are used differently for PFPS patients and substantially improve muscle activity, motor function, and quality of life. PMID:26185517

  11. Effects of Kinesio Taping versus McConnell Taping for Patellofemoral Pain Syndrome: A Systematic Review and Meta-Analysis

    PubMed Central

    Chang, Wen-Dien; Chen, Fu-Chen; Lee, Chia-Lun; Lin, Hung-Yu; Lai, Ping-Tung

    2015-01-01

    Objectives. To conduct a systematic review comparing the effects of Kinesio taping with McConnell taping as a method of conservative management of patients with patellofemoral pain syndrome (PFPS). Methods. MEDLINE, PUBMED, EMBASE, AMED, and the Cochrane Central Register of Control Trials electronic databases were searched through July 2014. Controlled studies evaluating the effects of Kinesio or McConnell taping in PFPS patients were retrieved. Results. Ninety-one articles were selected from the articles that were retrieved from the databases, and 11 articles were included in the analysis. The methods, evaluations, and results of the articles were collected, and the outcomes of patellar tapings were analyzed. Kinesio taping can reduce pain and increase the muscular flexibility of PFPS patients, and McConnell taping also had effect in pain relief and patellar alignment. Meta-analysis showed small effect in pain reduction and motor function improvement and moderate effect in muscle activity change among PFPS patients using Kinesio taping. Conclusions. Kinesio taping technique used for muscles can relieve pain but cannot change patellar alignment, unlike McConnell taping. Both patellar tapings are used differently for PFPS patients and substantially improve muscle activity, motor function, and quality of life. PMID:26185517

  12. Faceted ceramic fibers, tapes or ribbons and epitaxial devices therefrom

    SciTech Connect

    Goyal, Amit

    2013-07-09

    A crystalline article includes a single-crystal ceramic fiber, tape or ribbon. The fiber, tape or ribbon has at least one crystallographic facet along its length, which is generally at least one meter long. In the case of sapphire, the facets are R-plane, M-plane, C-plane or A-plane facets. Epitaxial articles, including superconducting articles, can be formed on the fiber, tape or ribbon.

  13. Faceted ceramic fibers, tapes or ribbons and epitaxial devices therefrom

    SciTech Connect

    Goyal, Amit

    2012-07-24

    A crystalline article includes a single-crystal ceramic fiber, tape or ribbon. The fiber, tape or ribbon has at least one crystallographic facet along its length, which is generally at least one meter long. In the case of sapphire, the facets are R-plane, M-plane, C-plane or A-plane facets. Epitaxial articles, including superconducting articles, can be formed on the fiber, tape or ribbon.

  14. Printed-Circuit Tape Measures For X-Ray Inspections

    NASA Technical Reports Server (NTRS)

    Sullivan, John E., Jr.

    1990-01-01

    Known pattern impressed on x-ray image for reference. Tapes made by flexible-printed-circuit technology provides identification and position references for x-ray images of weld joints. Proposed tapes consist of etched copper patterns on flexible substrates. X-rays record pattern of tape on film beneath butt-welded panels. Pattern becomes convenient reference for analysis and digitization of x-ray image.

  15. Getting in Taped, Part I and Part II

    ERIC Educational Resources Information Center

    Cundy, H. M.; Higgins, J.

    1971-01-01

    This article is in two parts: discussion of mathematical concepts involved in converting the reading from the tape-recorder counter which counts the turns of the run-off spool to that from the counter which counts turns of the take-up spool; calculating the length of tape run off when given the reading from the tape-recorder counter of the run-off…

  16. STS-109 Mission Highlights Resource Tape

    NASA Astrophysics Data System (ADS)

    2002-05-01

    This video, Part 2 of 4, shows the activities of the STS-109 crew (Scott Altman, Commander; Duane Carey, Pilot; John Grunsfeld, Payload Commander; Nancy Currie, James Newman, Richard Linnehan, Michael Massimino, Mission Specialists) during flight days 4 and 5. The activities from other flights days can be seen on 'STS-109 Mission Highlights Resource Tape' Part 1 of 4 (internal ID 2002139471), 'STS-109 Mission Highlights Resource Tape' Part 3 of 4 (internal ID 2002139476), and 'STS-109 Mission Highlights Resource Tape' Part 4 of 4 (internal ID 2002137577). The primary activities during these days were EVAs (extravehicular activities) to replace two solar arrays on the HST (Hubble Space Telescope). Footage from flight day 4 records an EVA by Grunsfeld and Linnehan, including their exit from Columbia's payload bay airlock, their stowing of the old HST starboard rigid array on the rigid array carrier in Columbia's payload bay, their attachment of the new array on HST, the installation of a new starboard diode box, and the unfolding of the new array. The pistol grip space tool used to fasten the old array in its new location is shown in use. The video also includes several shots of the HST with Earth in the background. On flight day 5 Newman and Massimino conduct an EVA to change the port side array and diode box on HST. This EVA is very similar to the one on flight day 4, and is covered similarly in the video. A hand operated ratchet is shown in use. In addition to a repeat of the previous tasks, the astronauts change HST's reaction wheel assembly, and because they are ahead of schedule, install installation and lubricate an instrument door on the telescope. The Earth views include a view of Egypt and Israel, with the Nile River, Red Sea, and Mediterranean Sea.

  17. STS-109 Mission Highlights Resource Tape

    NASA Astrophysics Data System (ADS)

    2002-05-01

    This video, Part 4 of 4, shows footage of crew activities from flight days 8 through 12 of STS-109. The crew included: Scott Altman, Commander; Duane Carey, Pilot; John Grunsfeld, Payload Commander; Nancy Currie, Richard Linnehan, James Newman, Michael Massimino, Mission Speicalists. The activities from other flights days can be seen on 'STS-109 Mission Highlights Resource Tape' Part 1 of 4 (internal ID 2002139471), 'STS-109 Mission Highlights Resource Tape' Part 2 of 4 (internal ID 2002137664), and 'STS-109 Mission Highlights Resource Tape' Part 3 of 4 (internal ID 2002139476). The primary activity on flight day 8 was an EVA (extravehicular activity) by Grunsfeld and Linnehan to install a cryocooler and radiator for the NICMOS (Near Infrared Camera and Multi-Object Spectrometer) on the HST (Hubble Space Telescope). Before returning to Columbia's airlock, the astronauts, with a cloudy background, hold onto the orbiter and offer their thoughts on the significance of their mission, the HST, and spaceflight. Footage from flight day 9 includes the grappling, unbearthing, and deployment of the HST from Columbia, and the crew coordinating and videotaping Columbia's departure. Flight day 10 was a relatively inactive day, and flight day 11 includes a checkout of Columbia's aerodynamic surfaces. Columbia landed on flight day 12, which is covered by footage of the crew members speaking during reentry, and their night landing, primarily shown through the orbiter's head-up display. The video includes numerous views of the HST, as well as views of the the Galapagos Islands, Madagascar, and Southern Africa with parts of the Atlantic, Indian, and Pacific Oceans, and part of the coast of Chile. The pistol grip space tool is shown in use, and the crew answers two messages from the public, including a message to Massimino from the Fire Department of New York.

  18. STS-109 Mission Highlights Resource Tape

    NASA Astrophysics Data System (ADS)

    2002-05-01

    This video, Part 1 of 4, shows the activities of the STS-109 crew (Scott Altman, Commander; Duane Carey, Pilot; John Grunsfeld, Payload Commander; Nancy Currie, James Newman, Richard Linnehan, Michael Massimino, Mission Specialists) during flight days 1 through 3. The activities from other flight days can be seen on 'STS 109 Mission Highlights Resource Tape' Part 2 of 4 (internal ID 2002137664), 'STS 109 Mission Highlights Resource Tape' Part 3 of 4 (internal ID 2002139471), and 'STS-109 Mission Highlights Resource Tape' Part 4 of 4 (internal ID 2002137577). The main activity recorded during flight day 1 is the liftoff of Columbia. Attention is given to suit-up, boarding, and pre-flight procedures. The pre-launch crew meal has no sound. The crew members often wave to the camera before liftoff. The jettisoning of the solid rocket boosters is shown, and the External Tank is seen as it falls to Earth, moving over African dunes in the background. There are liftoff replays, including one from inside the cockpit. The opening of the payload bay doors is seen from the rear of the shuttle's cockpit. The footage from flight day 2 shows the Flight Support System for bearthing the HST (Hubble Space Telescope). Crew preparations for the bearthing are shown. Flight day 3 shows the tracking of and approach to the HST by Columbia, including orbital maneuvers, the capture of the HST, and its lowering onto the Flight Support System. Many views of the HST are shown, including one which reveals an ocean and cloud background as the HST retracts a solar array.

  19. Tape-cast sensors and method of making

    DOEpatents

    Mukundan, Rangachary; Brosha, Eric L.; Garzon, Fernando H.

    2009-08-18

    A method of making electrochemical sensors in which an electrolyte material is cast into a tape. Prefabricated electrodes are then partially embedded between two wet layers of the electrolyte tape to form a green sensor, and the green sensor is then heated to sinter the electrolyte tape around the electrodes. The resulting sensors can be used in applications such as, but not limited to, combustion control, environmental monitoring, and explosive detection. A electrochemical sensor formed by the tape-casting method is also disclosed.

  20. Electromechanical characterization of silver-clad BSCCO tapes.

    SciTech Connect

    Salib, S.; Iyer, A. N.; Vipulanandan, C.; Salama, K.; Balachandran, U.; Energy Technology; Univ. of Houston

    1998-01-01

    During the fabrication of silver-clad BSCCO tapes they are subjected to stresses which could lead to degradation in their current transport property. In the present investigation, studies were made to evaluate the electromechanical characteristics of silver-clad BSCCO conductors. The tensile strain tolerance characteristics of the monofilament, multifilament and composite (15 and 30% of Ag powder by volume) tapes were evaluated at 77 K. The average irreversible strain of monofilament and composite tapes were 0.19 and 0.47%, respectively. No noticeable improvement in strain tolerance was observed with the multifilament tapes. Detailed phase and microstructural analysis have been conducted using scanning electron microscopy.

  1. Reel-to-reel substrate tape polishing system

    DOEpatents

    Selvamanickam, Venkat; Gardner, Michael T.; Judd, Raymond D.; Weloth, Martin; Qiao, Yunfei

    2005-06-21

    Disclosed is a reel-to-reel single-pass mechanical polishing system (100) suitable for polishing long lengths of metal substrate tape (124) used in the manufacture of high-temperature superconductor (HTS) coated tape, including multiple instantiations of a polishing station (114) in combination with a subsequent rinsing station (116) arranged along the axis of the metal substrate tape (124) that is translating between a payout spool (110a) and a take-up spool (110b). The metal substrate tape obtains a surface smoothness that is suitable for the subsequent deposition of a buffer layer.

  2. Bit error rate performance of Image Processing Facility high density tape recorders

    NASA Technical Reports Server (NTRS)

    Heffner, P.

    1981-01-01

    The Image Processing Facility at the NASA/Goddard Space Flight Center uses High Density Tape Recorders (HDTR's) to transfer high volume image data and ancillary information from one system to another. For ancillary information, it is required that very low bit error rates (BER's) accompany the transfers. The facility processes about 10 to the 11th bits of image data per day from many sensors, involving 15 independent processing systems requiring the use of HDTR's. When acquired, the 16 HDTR's offered state-of-the-art performance of 1 x 10 to the -6th BER as specified. The BER requirement was later upgraded in two steps: (1) incorporating data randomizing circuitry to yield a BER of 2 x 10 to the -7th and (2) further modifying to include a bit error correction capability to attain a BER of 2 x 10 to the -9th. The total improvement factor was 500 to 1. Attention is given here to the background, technical approach, and final results of these modifications. Also discussed are the format of the data recorded by the HDTR, the magnetic tape format, the magnetic tape dropout characteristics as experienced in the Image Processing Facility, the head life history, and the reliability of the HDTR's.

  3. Experimental studies of helical solenoid model based on YBCO tape-bridge joints

    SciTech Connect

    Yu, M.; Lombardo, V.; Turrioni, D.; Zlobin, A.V.; Flangan, G.; Lopes, M.L.; Johnson, R.P.; /Fermilab

    2011-06-01

    Helical solenoids that provide solenoid, helical dipole and helical gradient field components are designed for a helical cooling channel (HCC) proposed for cooling of muon beams in a muon collider. The high temperature superconductor (HTS), 12 mm wide and 0.1 mm thick YBCO tape, is used as the conductor for the highest-field section of HCC due to certain advantages, such as its electrical and mechanical properties. To study and address the design, and technological and performance issues related to magnets based on YBCO tapes, a short helical solenoid model based on double-pancake coils was designed, fabricated and tested at Fermilab. Splicing joints were made with Sn-Pb solder as the power leads and the connection between coils, which is the most critical element in the magnet that can limit the performance significantly. This paper summarizes the test results of YBCO tape and double-pancake coils in liquid nitrogen and liquid helium, and then focuses on the study of YBCO splices, including the soldering temperatures and pressures, and splice bending test.

  4. Slide Tape. A Guide to the Production of Slide-Tape Programmes.

    ERIC Educational Resources Information Center

    Rowatt, Robert W.

    Step by step instructions are provided for planning and executing a slide tape program, as well as diagrams of equipment for presenting such programs. Guidelines are given for ways to: (1) define a program's purpose and objectives, (2) complete a storyboard, (3) produce slides from transparencies and photographed artwork, (4) write on slides, (5)…

  5. Recording electrophysiological data on video tape: a superior and less costly alternative to conventional tape recorders.

    PubMed

    Chiang, R G; Knobloch, C A; Singleton, D M; Steel, C G; Davey, K G

    1985-10-01

    Electrical potentials recorded extracellularly from the sinus gland of the isopod, Oniscus asellus, were stored on video tape with the aid of a digital-audio (DA) processor and a video cassette recorder (VCR). The DA processor transforms the analog signal to digital pulses of equal amplitude and converts these pulses into a television signal for recording on video tape. In playback, the DA processor reconverts the pulses to an analog signal with negligible distortion. When viewed on the oscilloscope screen, electrical potentials reproduced by this method were indistinguishable from electrical potentials recorded 'live' from the sinus gland. However, electrical potentials recorded from the same sinus gland and reproduced by a conventional FM tape recorder were easily differentiated from the 'live' recording. The special effects inherent in the VCR (e.g. stop action, frame advance) also permitted detailed analysis of spontaneously occurring electrical potentials. Special effects were not possible with the FM tape recorder. The price, ease of operation and ability to produce extremely high quality recordings, makes the DA processor and VCR an exceptional system for storing electrophysiological data. PMID:4058060

  6. Estimation of hysteretic losses for MgB2 tapes under the operating conditions of a generator

    NASA Astrophysics Data System (ADS)

    Vargas-Llanos, Carlos Roberto; Zermeño, Víctor M. R.; Sanz, Santiago; Trillaud, Frederic; Grilli, Francesco

    2016-03-01

    Hysteretic losses in the MgB2 wound superconducting coils of a 550 kW synchronous hybrid scaled generator were estimated as part of the European project SUPRAPOWER led by the Spanish Fundación Tecnalia Research & Innovation. Particular interest was given to the losses caused by the magnetic flux ripples in the rotor coils originating from the conventional stator during nominal operation. To compute these losses, a 2D finite element analysis was conducted and Maxwell’s equations written in the H-formulation were solved considering the nonlinear material properties of the conductor materials. The modeled tapes are made of multiple MgB2 filaments embedded in a Ni matrix and soldered to a high purity copper strip and insulated with Dacron braid. Three geometrical models of single tape cross sections of decreasing complexity were studied: (1) the first model reproduced closely the actual cross section obtained from tape micrographs. (2) The second model was obtained from the computed elasto-plastic deformation of a round Ni wire. (3) The third model was based on a simplified cross section with the superconducting filaments bundled in a single elliptical bulky structure. The last geometry allowed the validation of the modeling technique by comparing numerical losses with results from well-established analytical expressions. Additionally, the following cases of filament transpositions of the multi-filamentary tape were studied: no transposition, partial and full transposition; thereby improving understanding of the relevance of the tape fabrication process on the magnitude of the determination of ac losses. Finally, choosing the right level of geometrical detail, the following operational regimes of the machine and its impact on individual superconducting tape losses in the rotor were studied: bias-dc current, ramping current under ramping background field and magnetic flux ripples under dc background current and field.

  7. Tape It! Using Audio Tapes as an Integral Part of a Multi-Media, Multi-Material Approach to Social Studies in the Intermediate Grades

    ERIC Educational Resources Information Center

    Gerlach, Gail J.

    1977-01-01

    Describes the use of audio tapes in the social studies classroom. Topics discussed include: using commercial learning aids, using the audio tape, taping directions, accommodating reading levels, recording current events, preparing students to use equipment, and using the tapes for evaluation. For journal availability, see SO 505 448. (Author/DB)

  8. Toxic release inventory (TRI), 1988 (on magnetic tape). Data file

    SciTech Connect

    1995-07-01

    Section 313 of the Emergency Planning and Community Right-to-Know Act (also known as Title III) of the Superfund Amendments and Reauthorization Act of 1986 (Public Law 99-499) requires EPA to establish a national inventory of toxic chemical emissions from certain facilities. The final Toxic Chemical Release Form R and regulations for the 1987 reporting year were published in the Federal Register on February 16, 1988 (53 FR 4500-4554). The list of toxic chemicals subject to reporting consisted initially of chemicals listed for similar reporting purposes by the states of New Jersey and Maryland. There are over 300 chemicals and categories on these lists. The reporting requirement applies to owners and operators of facilities that have 10 or more full-time employees, that are in Standard Industrial Classification (SIC) codes 20 through 39 (i.e., manufacturing facilities), and that manufacture (including importing), process or otherwise use a listed toxic chemical in excess of specified threshold quantities. The following information is required on Form R: the name, location and type of business; off-site locations to which the facility transfers toxic chemicals in waste; whether the chemical is manufactured (including importation), processed, or otherwise used and the general categories of use of the chemical; an estimate (in ranges) of the maximum amounts of the toxic chemical present at the facility at any time during the preceding year; quantity of the chemical entering each medium - air, land, water - annually; waste treatment/disposal methods and efficiency of methods for each waste stream; optional information on waste minimization; and a certification by a senior facility official that the report is complete and accurate. The law mandates that the data be made publicly available through a computer database.

  9. Toxic release inventory (TRI), 1989 (on magnetic tape). Data file

    SciTech Connect

    1995-07-01

    Section 313 of the Emergency Planning and Community Right-to-Know Act (also known as Title III) of the Superfund Amendments and Reauthorization Act of 1986 (Public Law 99-499) requires EPA to establish a national inventory of toxic chemical emissions from certain facilities. The final Toxic Chemical Release Form R and regulations for the 1987 reporting year were published in the Federal Register on February 16, 1988 (53 FR 4500-4554). The list of toxic chemicals subject to reporting consisted initially of chemicals listed for similar reporting purposes by the states of New Jersey and Maryland. There are over 300 chemicals and categories on these lists. The reporting requirement applies to owners and operators of facilities that have 10 or more full-time employees, that are in Standard Industrial Classification (SIC) codes 20 through 39 (i.e., manufacturing facilities), and that manufacture (including importing), process or otherwise use a listed toxic chemical in excess of specified threshold quantities. The following information is required on Form R: the name, location and type of business; off-site locations to which the facility transfers toxic chemicals in waste; whether the chemical is manufactured (including importation), processed, or otherwise used and the general categories of use of the chemical; an estimate (in ranges) of the maximum amounts of the toxic chemical present at the facility at any time during the preceding year; quantity of the chemical entering each medium - air, land, water - annually; waste treatment/disposal methods and efficiency of methods for each waste stream; optional information on waste minimization; and a certification by a senior facility official that the report is complete and accurate. The law mandates that the data be made publicly available through a computer database.

  10. Toxic release inventory (TRI), 1992 (on magnetic tape). Data file

    SciTech Connect

    1995-07-01

    Section 313 of the Emergency Planning and Community Right-to-Know Act (also known as Title III) of the Superfund Amendments and Reauthorization Act of 1986 (Public Law 99-499) requires EPA to establish a national inventory of toxic chemical emissions from certain facilities. The final Toxic Chemical Release Form R and regulations for the 1987 reporting year were published in the Federal Register on February 16, 1988 (53 FR 4500-4554). The list of toxic chemicals subject to reporting consisted initially of chemicals listed for similar reporting purposes by the states of New Jersey and Maryland. There are over 300 chemicals and categories on these lists. The reporting requirement applies to owners and operators of facilities that have 10 or more full-time employees, that are in Standard Industrial Classification (SIC) codes 20 through 39 (i.e., manufacturing facilities), and that manufacture (including importing), process or otherwise use a listed toxic chemical in excess of specified threshold quantities. The following information is required on Form R: the name, location and type of business; off-site locations to which the facility transfers toxic chemicals in waste; whether the chemical is manufactured (including importation), processed, or otherwise used and the general categories of use of the chemical; an estimate (in ranges) of the maximum amounts of the toxic chemical present at the facility at any time during the preceding year; quantity of the chemical entering each medium - air, land, water - annually; waste treatment/disposal methods and efficiency of methods for each waste stream; optional information on waste minimization; and a certification by a senior facility official that the report is complete and accurate. The law mandates that the data be made publicly available through a computer database.

  11. Toxic release inventory (TRI), 1993 (on magnetic tape). Data file

    SciTech Connect

    1995-07-01

    Section 313 of the Emergency Planning and Community Right-to-Know Act (also known as Title III) of the Superfund Amendments and Reauthorization Act of 1986 (Public Law 99-499) requires EPA to establish a national inventory of toxic chemical emissions from certain facilities. The final Toxic Chemical Release Form R and regulations for the 1987 reporting year were published in the Federal Register on February 16, 1988 (53 FR 4500-4554). The list of toxic chemicals subject to reporting consisted initially of chemicals listed for similar reporting purposes by the states of New Jersey and Maryland. There are over 300 chemicals and categories on these lists. The reporting requirement applies to owners and operators of facilities that have 10 or more full-time employees, that are in Standard Industrial Classification (SIC) codes 20 through 39 (i.e., manufacturing facilities), and that manufacture (including importing), process or otherwise use a listed toxic chemical in excess of specified threshold quantities. The following information is required on Form R: the name, location and type of business; off-site locations to which the facility transfers toxic chemicals in waste; whether the chemical is manufactured (including importation), processed, or otherwise used and the general categories of use of the chemical; an estimate (in ranges) of the maximum amounts of the toxic chemical present at the facility at any time during the preceding year; quantity of the chemical entering each medium - air, land, water - annually; waste treatment/disposal methods and efficiency of methods for each waste stream; optional information on waste minimization; and a certification by a senior facility official that the report is complete and accurate. The law mandates that the data be made publicly available through a computer database.

  12. Toxic release inventory (TRI), 1987 (on magnetic tape). Data file

    SciTech Connect

    1995-07-01

    Section 313 of the Emergency Planning and Community Right-to-Know Act (also known as Title III) of the Superfund Amendments and Reauthorization Act of 1986 (Public Law 99-499) requires EPA to establish a national inventory of toxic chemical emissions from certain facilities. The final Toxic Chemical Release Form R and regulations for the 1987 reporting year were published in the Federal Register on February 16, 1988 (53 FR 4500-4554). The list of toxic chemicals subject to reporting consisted initially of chemicals listed for similar reporting purposes by the states of New Jersey and Maryland. There are over 300 chemicals and categories on these lists. The reporting requirement applies to owners and operators of facilities that have 10 or more full-time employees, that are in Standard Industrial Classification (SIC) codes 20 through 39 (i.e., manufacturing facilities), and that manufacture (including importing), process or otherwise use a listed toxic chemical in excess of specified threshold quantities. The following information is required on Form R: the name, location and type of business; off-site locations to which the facility transfers toxic chemicals in waste; whether the chemical is manufactured (including importation), processed, or otherwise used and the general categories of use of the chemical; an estimate (in ranges) of the maximum amounts of the toxic chemical present at the facility at any time during the preceding year; quantity of the chemical entering each medium - air, land, water - annually; waste treatment/disposal methods and efficiency of methods for each waste stream; optional information on waste minimization; and a certification by a senior facility official that the report is complete and accurate. The law mandates that the data be made publicly available through a computer database.

  13. Toxic release inventory (TRI), 1991 (on magnetic tape). Data file

    SciTech Connect

    1995-07-01

    Section 313 of the Emergency Planning and Community Right-to-Know Act (also known as Title III) of the Superfund Amendments and Reauthorization Act of 1986 (Public Law 99-499) requires EPA to establish a national inventory of toxic chemical emissions from certain facilities. The final Toxic Chemical Release Form R and regulations for the 1987 reporting year were published in the Federal Register on February 16, 1988 (53 FR 4500-4554). The list of toxic chemicals subject to reporting consisted initially of chemicals listed for similar reporting purposes by the states of New Jersey and Maryland. There are over 300 chemicals and categories on these lists. The reporting requirement applies to owners and operators of facilities that have 10 or more full-time employees, that are in Standard Industrial Classification (SIC) codes 20 through 39 (i.e., manufacturing facilities), and that manufacture (including importing), process or otherwise use a listed toxic chemical in excess of specified threshold quantities. The following information is required on Form R: the name, location and type of business; off-site locations to which the facility transfers toxic chemicals in waste; whether the chemical is manufactured (including importation), processed, or otherwise used and the general categories of use of the chemical; an estimate (in ranges) of the maximum amounts of the toxic chemical present at the facility at any time during the preceding year; quantity of the chemical entering each medium - air, land, water - annually; waste treatment/disposal methods and efficiency of methods for each waste stream; optional information on waste minimization; and a certification by a senior facility official that the report is complete and accurate. The law mandates that the data be made publicly available through a computer database.

  14. Toxic release inventory (TRI), 1990 (on magnetic tape). Data file

    SciTech Connect

    1995-07-01

    Section 313 of the Emergency Planning and Community Right-to-Know Act (also known as Title III) of the Superfund Amendments and Reauthorization Act of 1986 (Public Law 99-499) requires EPA to establish a national inventory of toxic chemical emissions from certain facilities. The final Toxic Chemical Release Form R and regulations for the 1987 reporting year were published in the Federal Register on February 16, 1988 (53 FR 4500-4554). The list of toxic chemicals subject to reporting consisted initially of chemicals listed for similar reporting purposes by the states of New Jersey and Maryland. There are over 300 chemicals and categories on these lists. The reporting requirement applies to owners and operators of facilities that have 10 or more full-time employees, that are in Standard Industrial Classification (SIC) codes 20 through 39 (i.e., manufacturing facilities), and that manufacture (including importing), process or otherwise use a listed toxic chemical in excess of specified threshold quantities. The following information is required on Form R: the name, location and type of business; off-site locations to which the facility transfers toxic chemicals in waste; whether the chemical is manufactured (including importation), processed, or otherwise used and the general categories of use of the chemical; an estimate (in ranges) of the maximum amounts of the toxic chemical present at the facility at any time during the preceding year; quantity of the chemical entering each medium - air, land, water - annually; waste treatment/disposal methods and efficiency of methods for each waste stream; optional information on waste minimization; and a certification by a senior facility official that the report is complete and accurate. The law mandates that the data be made publicly available through a computer database.

  15. A visualization instrument to investigate the mechanical-electro properties of high temperature superconducting tapes under multi-fields

    NASA Astrophysics Data System (ADS)

    Liu, Wei; Zhang, Xingyi; Liu, Cong; Zhang, Wentao; Zhou, Jun; Zhou, YouHe

    2016-07-01

    We construct a visible instrument to study the mechanical-electro behaviors of high temperature superconducting tape as a function of magnetic field, strain, and temperature. This apparatus is directly cooled by a commercial Gifford-McMahon cryocooler. The minimum temperature of sample can be 8.75 K. A proportion integration differentiation temperature control is used, which is capable of producing continuous variation of specimen temperature from 8.75 K to 300 K with an optional temperature sweep rate. We use an external loading device to stretch the superconducting tape quasi-statically with the maximum tension strain of 20%. A superconducting magnet manufactured by the NbTi strand is applied to provide magnetic field up to 5 T with a homogeneous range of 110 mm. The maximum fluctuation of the magnetic field is less than 1%. We design a kind of superconducting lead composed of YBa2Cu3O7-x coated conductor and beryllium copper alloy (BeCu) to transfer DC to the superconducting sample with the maximum value of 600 A. Most notably, this apparatus allows in situ observation of the electromagnetic property of superconducting tape using the classical magnetic-optical imaging.

  16. A visualization instrument to investigate the mechanical-electro properties of high temperature superconducting tapes under multi-fields.

    PubMed

    Liu, Wei; Zhang, Xingyi; Liu, Cong; Zhang, Wentao; Zhou, Jun; Zhou, YouHe

    2016-07-01

    We construct a visible instrument to study the mechanical-electro behaviors of high temperature superconducting tape as a function of magnetic field, strain, and temperature. This apparatus is directly cooled by a commercial Gifford-McMahon cryocooler. The minimum temperature of sample can be 8.75 K. A proportion integration differentiation temperature control is used, which is capable of producing continuous variation of specimen temperature from 8.75 K to 300 K with an optional temperature sweep rate. We use an external loading device to stretch the superconducting tape quasi-statically with the maximum tension strain of 20%. A superconducting magnet manufactured by the NbTi strand is applied to provide magnetic field up to 5 T with a homogeneous range of 110 mm. The maximum fluctuation of the magnetic field is less than 1%. We design a kind of superconducting lead composed of YBa2Cu3O7-x coated conductor and beryllium copper alloy (BeCu) to transfer DC to the superconducting sample with the maximum value of 600 A. Most notably, this apparatus allows in situ observation of the electromagnetic property of superconducting tape using the classical magnetic-optical imaging.

  17. A visualization instrument to investigate the mechanical-electro properties of high temperature superconducting tapes under multi-fields.

    PubMed

    Liu, Wei; Zhang, Xingyi; Liu, Cong; Zhang, Wentao; Zhou, Jun; Zhou, YouHe

    2016-07-01

    We construct a visible instrument to study the mechanical-electro behaviors of high temperature superconducting tape as a function of magnetic field, strain, and temperature. This apparatus is directly cooled by a commercial Gifford-McMahon cryocooler. The minimum temperature of sample can be 8.75 K. A proportion integration differentiation temperature control is used, which is capable of producing continuous variation of specimen temperature from 8.75 K to 300 K with an optional temperature sweep rate. We use an external loading device to stretch the superconducting tape quasi-statically with the maximum tension strain of 20%. A superconducting magnet manufactured by the NbTi strand is applied to provide magnetic field up to 5 T with a homogeneous range of 110 mm. The maximum fluctuation of the magnetic field is less than 1%. We design a kind of superconducting lead composed of YBa2Cu3O7-x coated conductor and beryllium copper alloy (BeCu) to transfer DC to the superconducting sample with the maximum value of 600 A. Most notably, this apparatus allows in situ observation of the electromagnetic property of superconducting tape using the classical magnetic-optical imaging. PMID:27475594

  18. The Effects of Patellar Taping on Knee Joint Proprioception

    PubMed Central

    Callaghan, Michael J.; Selfe, James; Bagley, Pam J.; Oldham, Jacqueline A.

    2002-01-01

    Objective: To evaluate the effects of patellar taping on knee joint proprioception. Design and Setting: In a research unit, 3 proprioceptive tests were performed. For each of the tests, a standardized patellar taping technique was applied in random order. Subjects: Fifty-two healthy volunteers (27 women, 25 men; age, 23.2 ± 4.6 years; body mass index, 23.3 ± 3.7). Measurements: We measured active angle reproduction, passive angle reproduction, and threshold to detection of passive movement on an isokinetic dynamometer. Results: We found no significant differences between the tape and no-tape conditions in any of the 3 proprioceptive tests (P > .05). However, when the subjects' results for active angle reproduction and passive angle reproduction were graded as good (≤5°) and poor (>5°), taping was found to improve significantly those with poor proprioceptive ability (P < .01). Conclusions: Subjects with good proprioception did not benefit from patellar taping. However, in those healthy subjects with poor proprioceptive ability as measured by active and passive ankle reproduction, patellar taping provided proprioceptive enhancement. Further studies are needed to investigate the effect of patellar taping on the proprioceptive status of patients with patellofemoral pain syndrome. PMID:12937439

  19. Surreptitious Taping: The Arguments for and the Ethics against.

    ERIC Educational Resources Information Center

    Cooper, Thomas W.

    Much discussion within media ethics has focused on the acceptability of surreptitious tape recording of news sources by media professionals. The most common legal and social arguments supporting secret taping assert that recorders "hear" and "remember" better, are expedient and practical, protect against libel suits, provide historical…

  20. Using a Taped Intervention to Improve Kindergarten Students' Number Identification

    ERIC Educational Resources Information Center

    Krohn, Katherine R.; Skinner, Christopher H.; Fuller, Emily J.; Greear, Corrine

    2012-01-01

    A multiple baseline design across students was used to evaluate the effects of a taped numbers (TN) intervention on the number-identification accuracy of 4 kindergarten students. During TN, students attempted to name the numbers 0 through 9 on randomized lists before each number was provided via a tape player 2 s later. All 4 students showed…

  1. Tape the Teacher: Easier Field Trips for Large Classes

    ERIC Educational Resources Information Center

    Carter, Lynne; And Others

    1974-01-01

    Describes a tape-guided field trip that has been used successfully with college biology students in the University of California Botanical Garden. This program enables large numbers of students to make individual biological observations in the field with the aid of a specially tailored, taped guide. (JR)

  2. Equilibrium states and stability of pre-tensioned adhesive tapes

    PubMed Central

    Putignano, Carmine; Afferrante, Luciano; Mangialardi, Luigi

    2014-01-01

    Summary In the present paper we propose a generalization of the model developed in Afferrante, L.; Carbone, G.; Demelio, G.; Pugno, N. Tribol. Lett. 2013, 52, 439–447 to take into account the effect of the pre-tension in the tape. A detailed analysis of the peeling process shows the existence of two possible detachment regimes: one being stable and the other being unstable, depending on the initial configuration of the tape. In the stability region, as the peeling process advances, the peeling angle reaches a limiting value, which only depends on the geometry, on the elastic modulus of the tape and on the surface energy of adhesion. Vice versa, in the unstable region, depending on the initial conditions of the system, the tape can evolve towards a state of complete detachment or fail before reaching a state of equilibrium with complete adhesion. We find that the presence of pre-tension in the tape does not modify the stability behavior of the system, but significantly affects the pull-off force which can be sustained by the tape before complete detachment. Moreover, above a critical value of the pre-tension, which depends on the surface energy of adhesion, the tape will tend to spontaneously detach from the substrate. In this case, an external force is necessary to avoid spontaneous detachment and make the tape adhering to the substrate. PMID:25383283

  3. The Effects of Patellar Taping on Knee Joint Proprioception.

    PubMed

    Callaghan, Michael J; Selfe, James; Bagley, Pam J; Oldham, Jacqueline A

    2002-03-01

    OBJECTIVE: To evaluate the effects of patellar taping on knee joint proprioception. DESIGN AND SETTING: In a research unit, 3 proprioceptive tests were performed. For each of the tests, a standardized patellar taping technique was applied in random order. SUBJECTS: Fifty-two healthy volunteers (27 women, 25 men; age, 23.2 +/- 4.6 years; body mass index, 23.3 +/- 3.7). MEASUREMENTS: We measured active angle reproduction, passive angle reproduction, and threshold to detection of passive movement on an isokinetic dynamometer. RESULTS: We found no significant differences between the tape and no-tape conditions in any of the 3 proprioceptive tests (P >.05). However, when the subjects' results for active angle reproduction and passive angle reproduction were graded as good (5 degrees ), taping was found to improve significantly those with poor proprioceptive ability (P <.01). CONCLUSIONS: Subjects with good proprioception did not benefit from patellar taping. However, in those healthy subjects with poor proprioceptive ability as measured by active and passive ankle reproduction, patellar taping provided proprioceptive enhancement. Further studies are needed to investigate the effect of patellar taping on the proprioceptive status of patients with patellofemoral pain syndrome.

  4. Tape-Drive Based Plasma Mirror

    SciTech Connect

    Sokollik, Thomas; Shiraishi, Satomi; Osterhoff, Jens; Evans, Eugene; Gonsalves, Anthony; Nakamura, Kei; vanTilborg, Jeroen; Lin, Chen; Toth, Csaba; Leemans, Wim

    2011-07-22

    We present experimental results on a tape-drive based plasma mirror which could be used for a compact coupling of a laser beam into a staged laser driven electron accelerator. This novel kind of plasma mirror is suitable for high repetition rates and for high number of laser shots. In order to design a compact, staged laser plasma based accelerator or collider [1], the coupling of the laser beam into the different stages represents one of the key issues. To limit the spatial foot print and thus to realize a high overall acceleration gradient, a concept has to be found which realizes this in-coupling within a few centimeters (cf. Fig 1). The fluence of the laser pulse several centimeters away from the acceleration stage (focus) exceeds the damage threshold of any available mirror coating. Therefore, in reference [2] a plasma mirror was suggested for this purpose. We present experiments on a tape-drive based plasma mirror which could be used to reflect the focused laser beam into the acceleration stage. Plasma mirrors composed of antireflection coated glass substrates are usually used to improve the temporal laser contrast of laser pulses by several orders of magnitudes [3,4]. This is particularly important for laser interaction with solid matter, such as ion acceleration [5,6] and high harmonic generation on surfaces [7]. Therefore, the laser pulse is weekly focused onto a substrate. The main pulse generates a plasma and is reflected at the critical surface, whereas the low intensity pre-pulse (mainly the Amplified Spontaneous Emission pedestal) will be transmitted through the substrate before the mirror has been triggered. Several publications [3,4] demonstrate a conservation of the spatial beam quality and a reflectivity of about 70 %. The drawback of this technique is the limited repetition rate since for every shot a fresh surface has to be provided. In the past years several novel approaches for high repetition rate plasma mirrors have been developed [2, 8

  5. SHM of pipes using torsional waves generated by in situ magnetostrictive tapes

    NASA Astrophysics Data System (ADS)

    Kannan, E.; Maxfield, B. W.; Balasubramaniam, Krishnan

    2007-12-01

    Long-range, torsional guided waves generated in pipes using magnetostrictive sensors (MsSs) have great potential for applications to the structural health monitoring (SHM) of hard-to-inspect pipes. This paper reports an improved MsS technique (when compared to related techniques currently used for the NDT of pipes) that uses polymeric magnetic tape material that is suitable for use in a variety of industries as an SHM tool for pipes. Improvements include increased efficiency, reduced cost and increased long-term survivability of the sensor system. Transduction efficiency was increased by reducing the sensor eddy current losses and by using a field concentrator strip. For long-term monitoring, a low-cost magnetic oxide based MsS material (video recording tape) having the required magnetic properties was used. The MsS strips were oriented to generate non-dispersive torsional guided ultrasonic waves that propagate long distances with minimal mode conversion. Further, considering both safety and long-term survivability of the sensor, low-power ultrasonic instrumentation was developed and tested. Measurements reported here demonstrate the sensitivity of this sensor to both radial notches (saw cuts) and drilled holes. Results also show that magnetic anisotropy of the strip plays a role in generating torsional waves. It is envisioned that results obtained from the present study will significantly enhance the ability to monitor the long-term structural health of piping systems.

  6. Enhanced critical currents in (Gd,Y)Ba2Cu3Ox superconducting tapes with high levels of Zr addition

    SciTech Connect

    Selvamanickam, V; Chen, Y; Shi, T; Liu, Y; Khatri, ND; Liu, J; Yao, Y; Xiong, X; Lei, C; Soloveichik, S; Galstyan, E; Majkic, G

    2013-01-21

    The critical current and structural properties of (Gd,Y)BaCuO tapes made by metal organic chemical vapor deposition (MOCVD) with Zr addition levels up to 30 at.% have been investigated. The reduction in critical current beyond the previously optimized Zr addition level of 7.5 at.% was found to be due to structural deterioration of the (Gd,Y)Ba2Cu3Ox film. By a modified MOCVD process,enhanced critical current densities have been achieved with high levels of Zr addition,including 3.83 MA cm(-2) in 15 at.% Zr- added 1.1 mu m thick film at 77 K in zero magnetic field. Critical currents as high as 1072 A/ 12 mm have been reached in (Gd,Y) BaCuO tapes with 15 at.% Zr addition at 30 K in a field of 3 T applied perpendicular to the tape,corresponding to a pinning force value of 268 GN m(-3). The enhanced critical currents achievable with a high density of nanoscale defects by employing high levels of second- phase additions enable the performance targets needed for the use of HTS tapes in coil applications involving high magnetic fields at temperatures below 50 K to be met.

  7. Enhanced critical currents in (Gd,Y)Ba2Cu3Ox superconducting tapes with high levels of Zr addition

    NASA Astrophysics Data System (ADS)

    Selvamanickam, V.; Chen, Y.; Shi, T.; Liu, Y.; Khatri, N. D.; Liu, J.; Yao, Y.; Xiong, X.; Lei, C.; Soloveichik, S.; Galstyan, E.; Majkic, G.

    2013-03-01

    The critical current and structural properties of (Gd,Y)BaCuO tapes made by metal organic chemical vapor deposition (MOCVD) with Zr addition levels up to 30 at.% have been investigated. The reduction in critical current beyond the previously optimized Zr addition level of 7.5 at.% was found to be due to structural deterioration of the (Gd,Y)Ba2Cu3Ox film. By a modified MOCVD process, enhanced critical current densities have been achieved with high levels of Zr addition, including 3.83 MA cm-2 in 15 at.% Zr-added 1.1 μm thick film at 77 K in zero magnetic field. Critical currents as high as 1072 A/12 mm have been reached in (Gd,Y)BaCuO tapes with 15 at.% Zr addition at 30 K in a field of 3 T applied perpendicular to the tape, corresponding to a pinning force value of 268 GN m-3. The enhanced critical currents achievable with a high density of nanoscale defects by employing high levels of second-phase additions enable the performance targets needed for the use of HTS tapes in coil applications involving high magnetic fields at temperatures below 50 K to be met.

  8. Investigating Delamination Migration in Composite Tape Laminates

    NASA Technical Reports Server (NTRS)

    Ratcliffe, James G.; DeCarvalho, Nelson V.

    2014-01-01

    A modification to a recently developed test specimen designed to investigate migration of a delamination between neighboring ply interfaces in tape laminates is presented. The specimen is a cross-ply laminated beam consisting of 40 plies with a polytetrafluoroethylene insert spanning part way along its length. The insert is located between a lower 0-degree ply (specimen length direction) and a stack of four 90-degree plies (specimen width direction). The modification involved a stacking sequence that promotes stable delamination growth prior to migration, and included a relocation of the insert from the specimen midplane to the interface between plies 14 and 15. Specimens were clamped at both ends onto a rigid baseplate and loaded on their upper surface via a piano hinge assembly, resulting in a predominantly flexural loading condition. Tests were conducted with the load-application point positioned at various locations along a specimen's span. This position affected the sequence of damage events during a test.

  9. Interpretation of the human skin biotribological behaviour after tape stripping

    PubMed Central

    Pailler-Mattei, C.; Guerret-Piécourt, C.; Zahouani, H.; Nicoli, S.

    2011-01-01

    The present study deals with the modification of the human skin biotribological behaviour after tape stripping. The tape-stripping procedure consists in the sequential application and removal of adhesive tapes on the skin surface in order to remove stratum corneum (SC) layers, which electrically charges the skin surface. The skin electric charges generated by tape stripping highly change the skin friction behaviour by increasing the adhesion component of the skin friction coefficient. It has been proposed to rewrite the friction adhesion component as the sum of two terms: the first classical adhesion term depending on the intrinsic shear strength, τ0, and the second term depending on the electric shear strength, τelec. The experimental results allowed to estimate a numerical value of the electric shear strength τelec. Moreover, a plan capacitor model with a dielectric material inside was used to modelize the experimental system. This physical model permitted to evaluate the friction electric force and the electric shear strength values to calculate the skin friction coefficient after the tape stripping. The comparison between the experimental and the theoretical value of the skin friction coefficient after the tape stripping has shown the importance of the electric charges on skin biotribological behaviour. The static electric charges produced by tape stripping on the skin surface are probably able to highly modify the interaction of formulations with the skin surface and their spreading properties. This phenomenon, generally overlooked, should be taken into consideration as it could be involved in alteration of drug absorption. PMID:21227961

  10. An Experimental Investigation of Damaged Arresting Gear Tapes for the Langley Aircraft Landing Dynamics Facility

    NASA Technical Reports Server (NTRS)

    Mason, Angela J.

    1999-01-01

    An experimental investigation was performed on damaged arresting gear tapes at the Langley Aircraft Landing Dynamics Facility. The arrestment system uses five pairs of tapes to bring the test carriage to a halt. The procedure used to determine when to replace the tapes consists of a close evaluation of each of the 10 tapes after each run. During this evaluation, each tape is examined thoroughly and any damage observed on the tape is recorded. If the damaged tape does not pass the inspection, the tape is replaced with a new one. For the past 13 years, the most commonly seen damage types are edge fray damage and transverse damage. Tests were conducted to determine the maximum tensile strength of a damaged arresting gear tape specimen. The data indicate that tapes exhibiting transverse damage can withstand higher loads than tapes with edge fray damage.

  11. Improving the Spacelab mass memory unit tape layout with a simulation model

    NASA Technical Reports Server (NTRS)

    Noneman, S. R.

    1984-01-01

    A tape drive called the Mass Memory Unit (MMU) stores software used by Spacelab computers. MMU tape motion must be minimized during typical flight operations to avoid a loss of scientific data. A projection of the tape motion is needed for evaluation of candidate tape layouts. A computer simulation of the scheduled and unscheduled MMU tape accesses is developed for this purpose. This simulation permits evaluations of candidate tape layouts by tracking and summarizing tape movements. The factors that affect tape travel are investigated and a heuristic is developed to find a good tape layout. An improved tape layout for Spacelab I is selected after the evaluation of fourteen candidates. The simulation model will provide the ability to determine MMU layouts that substantially decrease the tape travel on future Spacelab flights.

  12. Study of the potential of three different MgB2 tapes for application in cylindrical coils operating at 20 K

    NASA Astrophysics Data System (ADS)

    Pitel, J.; Kováč, P.; Tropeano, M.; Grasso, G.

    2015-05-01

    The goal of this theoretical study is to illustrate the potential of three different MgB2 tapes, developed by Columbus Superconductors, for application in cylindrical coils. First, the distribution of critical currents and electric fields of individual turns is compared when the winding of the model coil is made with tapes having different Ic(B) and anisotropy values. Second, the influence of the winding geometry on basic parameters of cylindrical coils which consist of a set of pancake coils, such as critical current Icmin, central magnetic field B0 and stored energy E, is analysed. The winding geometry of the coils, i.e. the outer winding radius and the coil length, with the same inner winding radius, was changed from a disc shape to a long thin solenoid in such a way that the overall tape length was held constant, and considered as a parameter. Finally, the winding cross-section of the coil is optimized with respect to the constant tape length in order to reach the maximum central field. The results of calculations show that for a given overall tape length and inner winding radius there exists only one winding geometry which generates the maximum central field. The overall tape length, as a parameter, is changed in a broad range from 500 m to 10 km. All calculations were performed using the experimental data measured at 20 K while the effect of the anisotropy in the Ic(B) characteristic of the short samples is taken into account.

  13. Freeze Tape Casting of Functionally Graded Porous Ceramics

    NASA Technical Reports Server (NTRS)

    Sofie, Stephen W.

    2007-01-01

    Freeze tape casting is a means of making preforms of ceramic sheets that, upon subsequent completion of fabrication processing, can have anisotropic and/or functionally graded properties that notably include aligned and graded porosity. Freeze tape casting was developed to enable optimization of the microstructures of porous ceramic components for use as solid oxide electrodes in fuel cells: Through alignment and grading of pores, one can tailor surface areas and diffusion channels for flows of gas and liquid species involved in fuel-cell reactions. Freeze tape casting offers similar benefits for fabrication of optimally porous ceramics for use as catalysts, gas sensors, and filters.

  14. MAGNETIC RECORDING HEAD

    DOEpatents

    Merrill, L.C.

    1958-06-17

    An electromagetic recording head is described for simultaneous recording of a plurality of signals within a small space on a magnetically semsitized medium. Basically the head structure comprises a non-magnetic centerpiece provided with only first and second groups of spaced cut-out slots respectively on opposite sides of the centerpiece. The two groups of slots are in parallel alignment and the slots of one group are staggered with respect to the slots of the other group so that one slot is not directly opposite another slot. Each slot has a magnet pole piece disposed therein and cooperating with a second pole and coil to provide a magnetic flux gap at the upper end of the slot. As a tape is drawn over the upper end of the centerpiece the individual magnetic circuits are disposed along its width to provide means for simultaneously recording information on separate portions, tracks. of the tape.

  15. Numerical analysis of stress distribution in Cu-stabilized GdBCO CC tapes during anvil tests for the evaluation of transverse delamination strength

    NASA Astrophysics Data System (ADS)

    Dizon, John Ryan C.; Gorospe, Alking B.; Shin, Hyung-Seop

    2014-05-01

    Rare-earth-Ba-Cu-O (REBCO) based coated conductors (CCs) are now being used for electric device applications. For coil-based applications such as motors, generators and magnets, the CC tape needs to have robust mechanical strength along both the longitudinal and transverse directions. The CC tape in these coils is subjected to transverse tensile stresses during cool-down and operation, which results in delamination within and between constituent layers. In this study, in order to explain the behaviour observed in the evaluation of c-axis delamination strength in Cu-stabilized GdBCO CC tapes by anvil tests, numerical analysis of the mechanical stress distribution within the CC tape has been performed. The upper anvil size was varied in the analysis to understand the effect of anvil size on stress distribution within the multilayered CC tape, which is closely related to the delamination strength, delamination mode and delamination sites that were experimentally observed. The numerical simulation results showed that, when an anvil size covering the whole tape width was used, the REBCO coating film was subjected to the largest stress, which could result in low mechanical delamination and electromechanical delamination strengths. Meanwhile, when smaller-sized anvils were used, the copper stabilizer layer would experience the largest stress among all the constituent layers of the CC tape, which could result in higher mechanical and electromechanical delamination strengths, as well as high scattering of both of these delamination strengths. As a whole, the numerical simulation results could explain the damage evolution observed in CC tapes tested under transverse tensile stress, as well as the transverse tensile stress response of the critical current, Ic.

  16. Design and loss calculations of a 100-kVA transformer employing multi-filamentary Bi-2223 Ag sheathed superconducting tapes

    NASA Astrophysics Data System (ADS)

    Darmann, Frank

    2001-09-01

    A dimensional analysis for the design of a 100 kVA, 3 phase, iron core, 6.6 kV/240 V, Wye-Wye connected transformer employing Ag sheathed Bi-2223 high-temperature superconducting (HTSC) multi-filament tapes has been carried out. The mass, volume and tape length requirements were calculated over a range of core cross-sectional areas. The objective of this exercise was to minimise the overall transformer volume. A range of suitable designs was then selected. Finite element methods software was used to map the magnetic fields throughout the winding volume of each design, and to estimate the hysteretic loss at full load. The analysis of mass and volume with core area variation showed the presence of distinct points, which would minimise these quantities. However, it was found that these designs were impractical in reality due to the significant length and cost of tape that they would entail. It was also shown that the coil electrical losses in these designs were too high due to the length of tape required and from the higher hysteretic loss. By considering the factors of mass, volume, hysteretic loss, and tape length and cost, a suitable design was found which was a compromise between all the factors involved. Assuming HTSC tape available with a modest Je of 5000 A/cm2, it was found that the mass and volume of the transformer could be reduced significantly compared to that of a conventional transformer. The volume decreased from 206 to 129 dm3 and the dry mass decreased from 400 to 214 kg. The overall hysterises loss at full load was calculated to be 1290 W and the total length of tape required per phase is 1500 m. The minimum possible volume of the transformer for the given rating and engineering current density was found to be 83.8 dm3 requiring 3508 m of HTSC tape.

  17. Comparing superconducting and permanent magnets for magnetic refrigeration

    NASA Astrophysics Data System (ADS)

    Bjørk, R.; Nielsen, K. K.; Bahl, C. R. H.; Smith, A.; Wulff, A. C.

    2016-05-01

    We compare the cost of a high temperature superconducting (SC) tape-based solenoid with a permanent magnet (PM) Halbach cylinder for magnetic refrigeration. Assuming a five liter active magnetic regenerator volume, the price of each type of magnet is determined as a function of aspect ratio of the regenerator and desired internal magnetic field. It is shown that to produce a 1 T internal field in the regenerator a permanent magnet of hundreds of kilograms is needed or an area of superconducting tape of tens of square meters. The cost of cooling the SC solenoid is shown to be a small fraction of the cost of the SC tape. Assuming a cost of the SC tape of 6000 /m2 and a price of the permanent magnet of 100 /kg, the superconducting solenoid is shown to be a factor of 0.3-3 times more expensive than the permanent magnet, for a desired field from 0.5-1.75 T and the geometrical aspect ratio of the regenerator. This factor decreases for increasing field strength, indicating that the superconducting solenoid could be suitable for high field, large cooling power applications.

  18. Shuttle-Data-Tape XML Translator

    NASA Technical Reports Server (NTRS)

    Barry, Matthew R.; Osborne, Richard N.

    2005-01-01

    JSDTImport is a computer program for translating native Shuttle Data Tape (SDT) files from American Standard Code for Information Interchange (ASCII) format into databases in other formats. JSDTImport solves the problem of organizing the SDT content, affording flexibility to enable users to choose how to store the information in a database to better support client and server applications. JSDTImport can be dynamically configured by use of a simple Extensible Markup Language (XML) file. JSDTImport uses this XML file to define how each record and field will be parsed, its layout and definition, and how the resulting database will be structured. JSDTImport also includes a client application programming interface (API) layer that provides abstraction for the data-querying process. The API enables a user to specify the search criteria to apply in gathering all the data relevant to a query. The API can be used to organize the SDT content and translate into a native XML database. The XML format is structured into efficient sections, enabling excellent query performance by use of the XPath query language. Optionally, the content can be translated into a Structured Query Language (SQL) database for fast, reliable SQL queries on standard database server computers.

  19. 13 point video tape quality guidelines

    SciTech Connect

    Gaunt, R.

    1997-05-01

    Until high definition television (ATV) arrives, in the U.S. we must still contend with the National Television Systems Committee (NTSC) video standard (or PAL or SECAM-depending on your country). NTSC, a 40-year old standard designed for transmission of color video camera images over a small bandwidth, is not well suited for the sharp, full-color images that todays computers are capable of producing. PAL and SECAM also suffers from many of NTSC`s problems, but to varying degrees. Video professionals, when working with computer graphic (CG) images, use two monitors: a computer monitor for producing CGs and an NTSC monitor to view how a CG will look on video. More often than not, the NTSC image will differ significantly from the CG image, and outputting it to NTSC as an artist works enables the him or her to see the images as others will see it. Below are thirteen guidelines designed to increase the quality of computer graphics recorded onto video tape. Viewing your work in NTSC and attempting to follow the below tips will enable you to create higher quality videos. No video is perfect, so don`t expect to abide by every guideline every time.

  20. How to make sticky tapes stickier

    NASA Astrophysics Data System (ADS)

    Ponson, Laurent; Xia, Shuman; Ravichandran, Guruswami; Bhattacharya, Kaushik; California Institute of Technology Team

    2011-03-01

    Thin film adhesives have become increasingly important in various applications such as packaging and coating, and we benefit daily of their adhesion properties by using various kinds of tapes. Despite the apparent simplicity of these systems, a certain number of questions remain open. In particular, important efforts have been deployed recently to understand the effect of the complex tridimensional and highly heterogeneous structure at the interface of some adhesives, such as the one encountered in nature like the geckos toes. Although inspired by these natural adhesives, we studied a much simpler system, and however largely unexplored: a thin film with spatially varying adhesion energy and elastic properties. We will show how these heterogeneities introduced at the microscale can generate quite unexpected macroscopic behaviors, and that one can this way design stronger adhesives with new properties. Beyond their practical interests, these systems involve long range elastic interactions and heterogeneities resulting in a rich and complex physics that will be illustrated through experimental examples and their theoretical interpretation.

  1. Measure Guideline: Guidance on Taped Insulating Sheathing Drainage Planes

    SciTech Connect

    Grin, A.; Lstiburek, J.

    2014-09-01

    The goal of this research is to provide durable and long-term water management solutions using exterior insulating sheathing as part of the water management system. It is possible to tape or seal the joints in insulating sheathing to create a drainage plane and even an air control layer. There exists the material durability component of the tape as well as the system durability component being the taped insulating sheathing as the drainage plane. This measure guideline provides best practice and product recommendations from the interviewed contractors and homebuilders who collectively have a vast amount of experience. Three significant issues were discussed with the group, which are required to make taped insulating sheathing a simple, long-term, and durable drainage plane: horizontal joints should be limited or eliminated wherever possible; where a horizontal joint exists use superior materials; and frequent installation inspection and regular trade training are required to maintain proper installation.

  2. 11. PAINTERS REMOVING MASKING TAPE, VIEW LOOKING SOUTH FROM BOTTOM ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    11. PAINTERS REMOVING MASKING TAPE, VIEW LOOKING SOUTH FROM BOTTOM FLOOR OF DRYDOCK NO. 5. - Naval Base Philadelphia-Philadelphia Naval Shipyard, Dry Dock No. 5, League Island, Philadelphia, Philadelphia County, PA

  3. Creating and Using Video Tapes for Cartographic Demonstrations.

    ERIC Educational Resources Information Center

    Andrews, Sona K.; Gersmehl, Philip J.

    1986-01-01

    Offers nine suggestions for video tape production and instructional use in a student laboratory for a cartography course. Briefly discusses costs and benefits, including more time for instructors to focus on specific techniques and individual questions. (TRS)

  4. STS-34 mission highlights resource tape, part 1

    NASA Astrophysics Data System (ADS)

    1989-11-01

    This video tape contains important visual events including launch Galileo/IUS deployment, onboard crew activities, and landing. Also included is air-to-ground transmission between the crew and Mission Control.

  5. Accuracy testing of electric groundwater-level measurement tapes

    USGS Publications Warehouse

    Jelinski, Jim; Clayton, Christopher S.; Fulford, Janice M.

    2015-01-01

    The accuracy tests demonstrated that none of the electric-tape models tested consistently met the suggested USGS accuracy of ±0.01 ft. The test data show that the tape models in the study should give a water-level measurement that is accurate to roughly ±0.05 ft per 100 ft without additional calibration. To meet USGS accuracy guidelines, the electric-tape models tested will need to be individually calibrated. Specific conductance also plays a part in tape accuracy. The probes will not work in water with specific conductance values near zero, and the accuracy of one probe was unreliable in very high conductivity water (10,000 microsiemens per centimeter).

  6. Gait Kinematics After Taping in Participants With Chronic Ankle Instability

    PubMed Central

    Chinn, Lisa; Dicharry, Jay; Hart, Joseph M.; Saliba, Susan; Wilder, Robert; Hertel, Jay

    2014-01-01

    Context: Chronic ankle instability is characterized by repetitive lateral ankle sprains. Prophylactic ankle taping is a common intervention used to reduce the risk of ankle sprains. However, little research has been conducted to evaluate the effect ankle taping has on gait kinematics. Objective: To investigate the effect of taping on ankle and knee kinematics during walking and jogging in participants with chronic ankle instability. Design: Controlled laboratory study. Setting: Motion analysis laboratory. Patients or Participants: A total of 15 individuals (8 men, 7 women; age = 26.9 ± 6.8 years, height = 171.7 ± 6.3 cm, mass = 73.5 ± 10.7 kg) with self-reported chronic ankle instability volunteered. They had an average of 5.3 ± 3.1 incidences of ankle sprain. Intervention(s): Participants walked and jogged in shoes on a treadmill while untaped and taped. The tape technique was a traditional preventive taping procedure. Conditions were randomized. Main Outcome Measure(s): Frontal-plane and sagittal-plane ankle and sagittal-plane knee kinematics were recorded throughout the entire gait cycle. Group means and 90% confidence intervals were calculated, plotted, and inspected for percentages of the gait cycle in which the confidence intervals did not overlap. Results: During walking, participants were less plantar flexed from 64% to 69% of the gait cycle (mean difference = 5.73° ± 0.54°) and less inverted from 51% to 61% (mean difference = 4.34° ± 0.65°) and 76% to 81% (mean difference = 5.55° ± 0.54°) of the gait cycle when taped. During jogging, participants were less dorsiflexed from 12% to 21% (mean difference = 4.91° ± 0.18°) and less inverted from 47% to 58% (mean difference = 6.52° ± 0.12°) of the gait cycle when taped. No sagittal-plane knee kinematic differences were found. Conclusions: In those with chronic ankle instability, taping resulted in a more neutral ankle position during walking and jogging in shoes on a treadmill. This change in

  7. Generation and physical characteristics of the ERTS MSS system corrected computer compatible tapes

    NASA Technical Reports Server (NTRS)

    Thomas, V. L.

    1973-01-01

    The generation and format are discussed of the ERTS system corrected multispectral scanner computer compatible tapes. The discussion includes spacecraft sensors, scene characteristics, data transmission, and conversion of data to computer compatible tapes at the NASA Data Processing Facility. Geometeric and radiometric corrections, tape formats, and the physical characteristics of the tapes are also included.

  8. Generation and physical characteristics of the LANDSAT-1, -2 and -3 MSS computer compatible tapes

    NASA Technical Reports Server (NTRS)

    Thomas, V. L.

    1977-01-01

    The generation and format of the LANDSAT 1, 2, and 3 system corrected multispectral scanner computer compatible tapes are discussed. Included in the discussion are the spacecraft sensors, scene characteristics, the transmission of data, and the conversion of the data to computer compatible tapes. Also included in the discussion are geometric and radiometric corrections, tape formats, and the physical characteristics of the tape.

  9. Nickel plating connector ends on tape processed slapper detonator cables

    SciTech Connect

    Bruns, R.J.

    1989-02-28

    A nickel spot plater has been built as an addition to the other reel-to-reel processing equipment in the Tape Process Laboratory at Mound. This plater, like most of the equipment in the Tape Process Laboratory, is a prototype built to meet Mound's product requirements. This Plating System enables Mound to selectively plate specific areas (connector ends) on a flexible printed circuit cable. 6 refs., 11 figs., 1 tab.

  10. VIEW OF CABLES AND TAPES ASSOCIATED WITH ADRIVE CONTROL ROD ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VIEW OF CABLES AND TAPES ASSOCIATED WITH A-DRIVE CONTROL ROD SYSTEM, AT LEVEL +15’, DIRECTLY ABOVE PDP CONTROL ROOM, LOOKING NORTHWEST. THE CABLES FROM THE PDP ROOM GO THROUGH THE CONCRETE WALL, MAKE A RIGHT ANGLE TURN DOWNWARD, AND DESCEND INTO THE PDP CONTROL ROOM AS VERTICAL TAPES - Physics Assembly Laboratory, Area A/M, Savannah River Site, Aiken, Aiken County, SC

  11. Progress Toward Demonstrating a High Performance Optical Tape Recording Technology

    NASA Technical Reports Server (NTRS)

    Oakley, W. S.

    1996-01-01

    This paper discusses the technology developments achieved during the first year of a program to develop a high performance digital optical tape recording device using a solid state, diode pumped, frequency doubled green laser source. The goal is to demonstrate, within two years, useful read/write data transfer rates to at least 100 megabytes per second and a user capacity of up to one terabyte per cartridge implemented in a system using a '3480' style mono-reel tape cartridge.

  12. Strongly enhanced current densities in Sr0.6K0.4Fe2As2 + Sn superconducting tapes

    PubMed Central

    Lin, He; Yao, Chao; Zhang, Xianping; Zhang, Haitao; Wang, Dongliang; Zhang, Qianjun; Ma, Yanwei; Awaji, Satoshi; Watanabe, Kazuo

    2014-01-01

    Improving transport current has been the primary topic for practical application of superconducting wires and tapes. However, the porous nature of powder-in-tube (PIT) processed iron-based tapes is one of the important reasons for low critical current density (Jc) values. In this work, the superconducting core density of ex-situ Sr0.6K0.4Fe2As2 + Sn tapes, prepared from optimized precursors, was significantly improved by employing a simple hot pressing as an alternative route for final sintering. The resulting samples exhibited optimal critical temperature (Tc), sharp resistive transition, small resistivity and high Vickers hardness (Hv) value. Consequently, the transport Jc reached excellent values of 5.1 × 104 A/cm2 in 10 T and 4.3 × 104 A/cm2 in 14 T at 4.2 K, respectively. Our tapes also exhibited high upper critical field Hc2 and almost field-independent Jc. These results clearly demonstrate that PIT pnictide wire conductors are very promising for high-field magnet applications. PMID:24663054

  13. The effect of Kinesio Taping on handgrip strength.

    PubMed

    Lemos, Thiago Vilela; Pereira, Kelice Cristina; Protássio, Carina Celedonio; Lucas, Lorrane Barbosa; Matheus, Joao Paulo C

    2015-03-01

    [Purpose] The purpose of this research was to evaluate the change in muscle function induced by a Kinesio Tape application with no or moderate tension, to the dominant and non-dominant arms. [Subjects and Methods] This research was a quantitative study, in which 75 women participated. The subjects, aged 18-30 years, were divided into 3 groups, Kinesio, Kinesio without Tension, and Control, and they were assessed before the taping intervention and after 30 minutes, 24 hours, and 48 hours of taping. [Results] The Kinesio group subjects demonstrated an increase in handgrip strength after 30 minutes, 24 hours, and 48 hours of tape application compared to control. A statistically significant increase in strength was observed in the Kinesio group comparison to the Control after 24 hours and 48 hours for the right hand, and after 48 hours for the left hand. Improvement in the Kinesio group compared to the Kinesio without Tension was observed only after 24 hours of taping application, and only in the right hand. [Conclusion] The Kinesio Taping method augmented the handgrip strength of healthy women, and the increase in grip strength was maintained for 48 hours after its application; the dominant hand demonstrated the greatest strength values.

  14. Kinesio Taping effects on knee extension force among soccer players

    PubMed Central

    Serra, Maysa V. G. B.; Vieira, Edgar R.; Brunt, Denis; Goethel, Márcio F.; Gonçalves, Mauro; Quemelo, Paulo R. V.

    2015-01-01

    Background: Kinesio Taping (KT) is widely used, however the effects of KT on muscle activation and force are contradictory. Objective: To evaluate the effects of KT on knee extension force in soccer players. Method: This is a clinical trial study design. Thirty-four subjects performed two maximal isometric voluntary contractions of the lower limbs pre, immediately post, and 24 hours after tape application on the lower limbs. Both lower limbs were taped, using K-Tape and 3M Micropore tape randomly on the right and left thighs of the participants. Isometric knee extension force was measured for dominant side using a strain gauge. The following variables were assessed: peak force, time to peak force, rate of force development until peak force, time to peak rate of force development, and 200 ms pulse. Results: There were no statistically significant differences in the variables assessed between KT and Micropore conditions (F=0.645, p=0.666) or among testing sessions (pre, post, and 24h after) (F=0.528, p=0.868), and there was no statistical significance (F=0.271, p=0.986) for interaction between tape conditions and testing session. Conclusion: KT did not affect the force-related measures assessed immediately and 24 hours after the KT application compared with Micropore application, during maximal isometric voluntary knee extension. PMID:25789557

  15. The effect of Kinesio Taping on handgrip strength

    PubMed Central

    Lemos, Thiago Vilela; Pereira, Kelice Cristina; Protássio, Carina Celedonio; Lucas, Lorrane Barbosa; Matheus, Joao Paulo C.

    2015-01-01

    [Purpose] The purpose of this research was to evaluate the change in muscle function induced by a Kinesio Tape application with no or moderate tension, to the dominant and non-dominant arms. [Subjects and Methods] This research was a quantitative study, in which 75 women participated. The subjects, aged 18–30 years, were divided into 3 groups, Kinesio, Kinesio without Tension, and Control, and they were assessed before the taping intervention and after 30 minutes, 24 hours, and 48 hours of taping. [Results] The Kinesio group subjects demonstrated an increase in handgrip strength after 30 minutes, 24 hours, and 48 hours of tape application compared to control. A statistically significant increase in strength was observed in the Kinesio group comparison to the Control after 24 hours and 48 hours for the right hand, and after 48 hours for the left hand. Improvement in the Kinesio group compared to the Kinesio without Tension was observed only after 24 hours of taping application, and only in the right hand. [Conclusion] The Kinesio Taping method augmented the handgrip strength of healthy women, and the increase in grip strength was maintained for 48 hours after its application; the dominant hand demonstrated the greatest strength values. PMID:25931682

  16. Temperature-and field dependent characterization of a twisted stacked-tape cable

    NASA Astrophysics Data System (ADS)

    Barth, C.; Takayasu, M.; Bagrets, N.; Bayer, C. M.; Weiss, K.-P.; Lange, C.

    2015-04-01

    The twisted stacked-tape cable (TSTC) is one of the major high temperature superconductor cable concepts combining scalability, ease of fabrication and high current density making it a possible candidate as conductor for large scale magnets. To simulate the boundary conditions of such a magnets as well as the temperature dependence of TSTCs a 1.16 m long sample consisting of 40, 4 mm wide SuperPower REBCO tapes is characterized using the ‘FBI’ (force-field-current) superconductor test facility of the Institute for Technical Physics of the Karlsruhe Institute of Technology. In a first step, the magnetic background field is cycled while measuring the current carrying capabilities to determine the impact of Lorentz forces on the TSTC sample performance. In the first field cycle, the critical current of the TSTC sample is tested up to 12 T. A significant Lorentz force of up to 65.6 kN m-1 at the maximal magnetic background field of 12 T result in a 11.8% irreversible degradation of the current carrying capabilities. The degradation saturates (critical cable current of 5.46 kA at 4.2 K and 12 T background field) and does not increase in following field cycles. In a second step, the sample is characterized at different background fields (4-12 T) and surface temperatures (4.2-37.8 K) utilizing the variable temperature insert of the ‘FBI’ test facility. In a third step, the performance along the length of the sample is determined at 77 K, self-field. A 15% degradation is obtained for the central part of the sample which was within the high field region of the magnet during the in-field measurements.

  17. An Atmospheric Tape Recorder: The Imprint of Tropical Tropopause Temperatures on Stratospheric Water Vapor

    NASA Technical Reports Server (NTRS)

    Mote, Philip W.; Rosenlof, Karen H.; McIntyre, Michael E.; Carr, Ewan S.; Gille, John C.; Holton, James R.; Kinnersley, Jonathan S.; Pumphrey, Hugh C.; Russell, James M., III; Waters, Joe W.

    1996-01-01

    We describe observations of tropical stratospheric water vapor q that show clear evidence of large-scale upward advection of the signal from annual fluctuations in the effective 'entry mixing ratio' q(sub E) of air entering the tropical stratosphere. In other words, air is 'marked,' on emergence above the highest cloud tops, like a signal recorded on an upward moving magnetic tape. We define q(sub E) as the mean water vapor mixing ratio, at the tropical tropopause, of air that will subsequently rise and enter the stratospheric 'overworld' at about 400 K. The observations show a systematic phase lag, increasing with altitude, between the annual cycle in q(sub E) and the annual cycle in q at higher altitudes. The observed phase lag agrees with the phase lag calculated assuming advection by the transformed Eulerian-mean vertical velocity of a q(sub E) crudely estimated from 100-hPa temperatures, which we use as a convenient proxy for tropopause temperatures. The phase agreement confirms the overall robustness of the calculation and strongly supports the tape recorder hypothesis. Establishing a quantitative link between q(sub E) and observed tropopause temperatures, however, proves difficult because the process of marking the tape depends subtly on both small- and large-scale processes. The tape speed, or large-scale upward advection speed, has a substantial annual variation and a smaller variation due to the quasi-biennial oscillation, which delays or accelerates the arrival of the signal by a month or two in the middle stratosphere. As the tape moves upward, the signal is attenuated with an e-folding time of about 7 to 9 months between 100 and 50 hPa and about 15 to 18 months between 50 and 20 hPa, constraining possible orders of magnitude both of vertical diffusion K(sub z) and of rates of mixing in from the extratropics. For instance, if there were no mixing in, then K(sub z) would be in the range 0.03-0.09 m(exp 2)/s; this is an upper bound on K(sub z).

  18. Influence of magnesium oxide nanoparticles embedded in Bi-2212/Ag tapes on their superconducting properties

    NASA Astrophysics Data System (ADS)

    Ilyushechkin, A. Yu.; Agranovskii, I. E.; Altman, I. S.; Zagainov, V. A.; Choi, M.

    2012-04-01

    A MgO-doped Bi2Sr2CaCu2O y (Bi-2212) high-temperature superconductor is investigated experimentally. The influence of the MgO particle concentration and size on the high-temperature superconductivity parameters is studied. It is shown that, when incorporated into the superconductor, MgO particles do not change their structure. The optimal parameters of the particles exerting the strongest effect on the material are found. The optimal size of the particle is in the range 40-50 nm for a cubic structure. Measures should be taken against clustering. Ways of particle preparation and incorporation into the superconductor are considered. The superconductivity of the material with embedded MgO particles is investigated. At temperatures close to 20 K, the magnetic field of doped tapes exceeds that of undoped ones by a factor of 2.5-10.0 depending on the MgO concentration. The temperature dependences of the superconducting properties of the doped tapes at different magnetic fields are presented.

  19. MAGNETS

    DOEpatents

    Hofacker, H.B.

    1958-09-23

    This patent relates to nmgnets used in a calutron and more particularly to means fur clamping an assembly of magnet coils and coil spacers into tightly assembled relation in a fluid-tight vessel. The magnet comprises windings made up of an assembly of alternate pan-cake type coils and spacers disposed in a fluid-tight vessel. At one end of the tank a plurality of clamping strips are held firmly against the assembly by adjustable bolts extending through the adjacent wall. The foregoing arrangement permits taking up any looseness which may develop in the assembly of coils and spacers.

  20. Accelerated aging studies and environmental stability of prototype tamper tapes

    SciTech Connect

    Wright, B.W.; Wright, C.W.; Bunk, A.R.

    1995-05-01

    This report describes the results of accelerated aging experiments (weathering) conducted on prototype tamper tapes bonded to a variety of surface materials. The prototype tamper tapes were based on the patented Confirm{reg_sign} tamper-indicating technology developed and produced by 3M Company. Tamper tapes bonded to surfaces using pressure sensitive adhesive (PSA) and four rapid-set adhesives were evaluated. The configurations of the PSA-bonded tamper tapes were 1.27-cm-wide Confirm{reg_sign} 1700 windows with vinyl underlay and 2.54-cm-wide Confirm{reg_sign} 1700 windows with vinyl and polyester underlays. The configurations of the rapid-set adhesive-bonded tamper tapes were 2.54-cm-wide Confirm{reg_sign} (1700, 1500 with and without primer, and 1300) windows with vinyl underlay. Surfaces used for bonding included aluminum, steel, stainless steel, Kevlar{reg_sign}, brass, copper, fiberglass/resin with and without gel coat, polyurethane-painted steel, acrylonitrile:butadiene:styrene plastic, polyester fiberglass board, Lexan polycarbonate, and cedar wood. Weathering conditions included a QUV cabinet (ultraviolet light at 60{degrees}C, condensing humidity at 40{degrees}C), a thermal cycling cabinet (-18{degrees}C to 46{degrees}C), a Weather-O-Meter (Xenon lamp), and exposure outdoors in Daytona Beach, Florida. Environmental aging exposures lasted from 7 weeks to 5 months. After exposure, the tamper tapes were visually examined and tested for transfer resistance. Tamper tapes were also exposed to a variety of chemical liquids (including organic solvents, acids, bases, and oxidizing liquids) to determine chemical resistance and to sand to determine abrasion resistance.

  1. Kinesio Tape and Shoulder-Joint Position Sense

    PubMed Central

    Aarseth, Lindsay M.; Suprak, David N.; Chalmers, Gordon R.; Lyon, Lonnie; Dahlquist, Dylan T.

    2015-01-01

    Context Joint position sense (JPS) is a key neuromuscular factor for developing and maintaining control of muscles around a joint. It is important when performing specialized tasks, especially at the shoulder. No researchers have studied how Kinesio Tape (KT) application affects JPS. Objective To investigate the effects of KT application and no tape on shoulder JPS at increasing shoulder elevations in athletes. Design Cross-sectional study. Setting University laboratory. Patients or Other Participants A total of 27 healthy athletes who did not participate in overhead sports (age = 20.44 ± 1.05 years, height = 175.02 ± 11.67 cm, mass = 70.74 ± 9.65 kg) with no previous pathologic shoulder conditions volunteered for the study. All participants were from 1 university. Intervention(s) Shoulder JPS was assessed at increasing elevations with and without KT application. Participants attempted to actively replicate 3 target positions with and without the KT and without visual guidance. Main Outcome Measure(s) We examined absolute and variable repositioning errors at increasing shoulder-elevation levels with and without KT application. Results Data revealed an interaction between tape and position for absolute error (F2,52 = 4.07, P = .02); simple effects revealed an increase in error, with KT demonstrating a 2.65° increase in error at 90° of elevation compared with no tape (t26 = 2.65, P = .01). The effect size was medium (ω2 = .135). Variable error showed no interaction of tape and position (F2,52 = .709, P = .50). Further analysis of simple effects was not needed. However, we still calculated the effect size and observed small effect sizes for tape (ω2 = .002), position (ω2 = .072), and tape by position (ω2 = .027). Conclusions At 90° of elevation, shoulder JPS was impaired by the application of KT. PMID:26090707

  2. The NT digital micro tape recorder

    NASA Astrophysics Data System (ADS)

    Sasaki, Toshikazu; Alstad, John; Younker, Mike

    The description of an audio recorder may at first glance seem out of place in a conference which has been dedicated to the discussion of the technology and requirements of mass data storage. However, there are several advanced features of the NT system which will be of interest to the mass storage technologist. Moreover, there are a sufficient number of data storage formats in current use which have evolved from their audio counterparts to recommend a close attention to major innovative introductions of audio storage formats. While the existing analog micro-cassette recorder has been (and will continue to be) adequate for various uses, there are significant benefits to be gained through the application of digital technology. The elimination of background tape hiss and the availability of two relatively wide band channels (for stereo recording), for example, would greatly enhance listenability and speech intelligibility. And with the use of advanced high-density recording and LSI circuit technologies, a digital micro recorder can realize unprecedented compactness with excellent energy efficiency. This is what was accomplished with the NT-1 Digital Micro Recorder. Its remarkably compact size contributes to its portability. The high-density NT format enables up to two hours of low-noise digital stereo recording on a cassette the size of a postage stamp. Its highly energy-efficient mechanical and electrical design results in low power consumption; the unit can be operated up to 7 hours (for continuous recording) on a single AA alkaline battery. Advanced user conveniences include a multifunction LCD readout. The unit's compactness and energy-efficiency, in particular, are attributes that cannot be matched by existing analog and digital audio formats. The size, performance, and features of the NT format are of benefit primarily to those who desire improved portability and audio quality in a personal memo product. The NT Recorder is the result of over ten years of

  3. Application of Kinesio Taping method for newborn swallowing difficultly

    PubMed Central

    Lin, Chien-Lin; Wu, Wei-Ting; Chang, Ke-Vin; Lin, Hong-Yi; Chou, Li-Wei

    2016-01-01

    Abstract Background: Preterm infants are at an increased risk of sucking problems, swallowing difficulty, and poor nourishment. During the neonatal period, the neurobehavioral organization of a preterm baby is poor compared with that of appropriate gestational age infants. Kinesio Taping has been widely used for edema control, joint protection, and proprioception training. With the help of augmentation of the sensory input for muscle facilitation and inhibition through tapping, the coordination of the target muscle groups can be improved. Until now, no research is available on the use of Kinesio Taping for the swallowing difficulty of infant. Methods: We reported a preterm infant suffering from brain edema at birth and swallowing difficultly until 40 weeks. The swallowing reflex was delayed. Moreover, lip closure and rooting reflex combined with the dysfunction grade of jaw movement were poor. We performed KT methods on the baby under the theory of the direction of the tape for facilitate or inhibit the muscle. Result: After the Kinesio Taping treatment, the sucking function was improved with good lip closure.One week later, the baby was discharged without the use of an oral gastric tube. Conclusion: Kinesio Taping contributed significantly to the improvement of impaired sucking and swallowing and could be implemented as a regular rehabilitative approach for infants suffering from these difficulties. PMID:27495080

  4. Materials for Heated Head Automated Thermoplastic Tape Placement

    NASA Technical Reports Server (NTRS)

    Jensen, Brian J.; Kinney, Megan C.; Cano, Roberto J.; Grimsley, Brian W.

    2012-01-01

    NASA Langley Research Center (LaRC) is currently pursuing multiple paths to develop out of autoclave (OOA) polymeric composite materials and processes. Polymeric composite materials development includes the synthesis of new and/or modified thermosetting and thermoplastic matrix resins designed for specific OOA processes. OOA processes currently under investigation include vacuum bag only (VBO) prepreg/composite fabrication, resin transfer molding (RTM), vacuum assisted resin transfer molding (VARTM) and heated head automated thermoplastic tape placement (HHATP). This paper will discuss the NASA Langley HHATP facility and capabilities and recent work on characterizing thermoplastic tape quality and requirements for quality part production. Samples of three distinct versions of APC-2 (AS4/PEEK) thermoplastic dry tape were obtained from two materials vendors, TENCATE, Inc. and CYTEC Engineered Materials** (standard grade and an experimental batch). Random specimens were taken from each of these samples and subjected to photo-microscopy and surface profilometry. The CYTEC standard grade of APC-2 tape had the most voids and splits and the highest surface roughness and/or waviness. Since the APC-2 tape is composed of a thermoplastic matrix, it offers the flexibility of reprocessing to improve quality, and thereby improve final quality of HHATP laminates. Discussions will also include potential research areas and future work that is required to advance the state of the art in the HHATP process for composite fabrication.

  5. Kinesiology tape does not facilitate muscle performance: A deceptive controlled trial.

    PubMed

    Poon, K Y; Li, S M; Roper, M G; Wong, M K M; Wong, O; Cheung, R T H

    2015-02-01

    Kinesiology tape (KinTape) is a therapeutic tape without much understanding of its mechanism. KinTape claims to increase cutaneous stimulation, which facilitates motor unit firing, and consequently improves functional performance; however these, benefits could be due to placebo effects. This study investigated the true effects of KinTape by a deceptive, randomized, and controlled trial. Thirty healthy participants performed isokinetic testing of three taping conditions: true facilitative KinTape, sham KinTape, and no KinTape. The participants were blindfolded during the evaluation. Under the pretense of applying adhesive muscle sensors, KinTape was applied to their quadriceps in the first two conditions. Normalized peak torque, normalized total work, and time to peak torque were measured at two angular speeds (60°/s and 180°/s) and analyzed with one-way repeated measures ANOVA. Participants were successfully deceived and they were ignorant about KinTape. No significant differences were found between normalized peak torque, normalized total work, and time to peak torque at 60°/s or 180°/s (p = 0.31-0.99) between three taping conditions. The results showed that KinTape did not facilitate muscle performance in generating higher peak torque, yielding a greater total work, or inducing an earlier onset of peak torque. These findings suggest that previously reported muscle facilitatory effects using KinTape may be attributed to placebo effects.

  6. Enhancement of critical current densities in (Ba,K)Fe2As2 wires and tapes using HIP technique

    NASA Astrophysics Data System (ADS)

    Pyon, Sunseng; Suwa, Takahiro; Park, Akiyoshi; Kajitani, Hideki; Koizumi, Norikiyo; Tsuchiya, Yuji; Awaji, Satoshi; Watanabe, Kazuo; Tamegai, Tsuyoshi

    2016-11-01

    (Ba,K)Fe2As2 superconducting wires and tapes are fabricated by using hot isostatic pressing (HIP) technique, and their superconducting properties are studied. In the HIP round wire, transport critical current density (J c) at 4.2 K has achieved record-high value of 175 kA cm-2 at zero field, and exceeds 20 kA cm-2 even at 100 kOe. Improvement of polycrystalline powder synthesis may play a key role for the enhancement of J c. In the HIP tape, even larger transport J c of 380 kA cm-2 is realized at zero field. Based on magnetization and magneto-optical measurements, possible further enhancement of J c is discussed.

  7. A New Tracking Method for Helical Scanning Optical Tape Recorder

    NASA Astrophysics Data System (ADS)

    Narahara, Tatsuya; Kamatani, Yoshiteru; Nakao, Takashi; Kumai, Satoshi; Ozue, Tadashi

    1993-11-01

    Using a new tracking method, high track density recording on an optical tape has been achieved with a helical-scanning optical tape recorder (HS-OTR). In this recorder, the tape is wrapped around a drum, which has a high numerical-aperture objective lens of 0.50, without contact with the rotating part by means of air pressure. In the optical design, moving parts, both focus and tracking actuators, light source and reproducing optics are placed outside the rotary drum. With this system, a high carrier-to-noise-ratio of 51 dB for 1 μm mark length has been achieved. Using the tracking method, which includes a starting point servo loop, written marks have been reproduced track by track with a 2 μm pitch.

  8. Experimental Investigations of Woven Textile Tape as Strain Sensor

    NASA Astrophysics Data System (ADS)

    Kannaian, T.; Naveen, V. S.; Muthukumar, N.; Thilagavathi, G.

    2015-10-01

    In this article, a strain sensitive textile based elastomeric tape sensor has been developed and process parameters for sensor development are optimized. Polyester yarns are used as base threads and rubber threads are used as elastomer for the sensor development. The sensor has been developed with the help of narrow width tape loom by introducing the silver coated nylon yarn in the middle of the tape structure. The influence of weave structure, number of conductive threads and rubber thread tension on sensor development has been optimized by using the Box-Behnken method and the results are analyzed using the Design expert software. From the results, it is found that six numbers of conductive threads in a plain weave structure with rubber thread tension of 750 g is suitable for the sensor to give high gauge factor of 1.626.

  9. Field analysis of a tape helix with embedded bio-media for microwave hyperthermia.

    PubMed

    Pathak, S K; Singh, S P

    1996-01-01

    A general field theory has been developed for the EM wave propagation on a tape helix with embedded bone, muscle, fat and skin co-axial biological layers in a multilayered dielectric environment. The electric and magnetic fields in every biological/dielectric layer is formulated in terms of complex modified Bessel functions and complex exponentials, i.e. in terms of complex radial and axial propagation constants for the azimuthally symmetric and higher order spatial harmonics. A complete dispersion relation is derived by substituting the field expressions into as many boundary conditions as there are unknown constants. The dispersion relation is numerically solved for the complex axial propagation constant and hence for the phase velocity and depth of penetration for n = 0 and 1 modes propagating along three dielectric loaded tape helices of different dimensions at several spot frequencies within the range of 300 MHz to 3.00 GHz. The results for variations in normalized phase velocity and depth of penetration with frequency for these modes separately and for the combined mode are presented. The patterns of specific absorption rate (SAR) across the cross-section of the dielectric loaded helices are also computed and presented. The variations with frequency, and cross-sectional dimension of the helix of the normalized phase velocity, axial depth and SAR across the cross-section of each of the helices are discussed for the modes considered. The theoretical results for the propagation constant obtained by using a tape helix model for the azimuthally symmetric mode propagating along a wire helix loaded with a phantom muscle sample of known dielectric constant are compared with experimental results and with those obtained theoretically employing a sheath helix model at 2.45 and 2.55 GHz. The use of a helix for human limb hyperthermia is also discussed.

  10. High current density electropolishing in the preparation of highly smooth substrate tapes for coated conductors

    DOEpatents

    Kreiskott, Sascha; Matias, Vladimir; Arendt, Paul N.; Foltyn, Stephen R.; Bronisz, Lawrence E.

    2009-03-31

    A continuous process of forming a highly smooth surface on a metallic tape by passing a metallic tape having an initial roughness through an acid bath contained within a polishing section of an electropolishing unit over a pre-selected period of time, and, passing a mean surface current density of at least 0.18 amperes per square centimeter through the metallic tape during the period of time the metallic tape is in the acid bath whereby the roughness of the metallic tape is reduced. Such a highly smooth metallic tape can serve as a base substrate in subsequent formation of a superconductive coated conductor.

  11. Mirror-touch and ticker tape experiences in synesthesia

    PubMed Central

    Chun, Charlotte A.; Hupé, Jean-Michel

    2013-01-01

    A fundamental question in the field of synesthesia is whether it is associated with other cognitive phenomena. The current study examined synesthesia's connections with phenomenal traits of mirror-touch and ticker tape experiences, as well as the representation of the three phenomena in the population, across gender and domain of work/study. Mirror-touch is the automatic, involuntary experience of tactile sensation on one's own body when others are being touched. For example, seeing another person's arm being stroked can evoke physical touch sensation on one's own arm. Ticker tape is the automatic visualization of spoken words or thoughts, such as a teleprompter. For example, when spoken to, a ticker taper might see mentally the spoken words displayed in front of his face or as coming out of the speaker's mouth. To explore synesthesia's associations with these phenomena, a diverse group (n = 3743) was systematically recruited from eight universities and one public museum in France to complete an online screening. Of the 1017 eligible respondents, synesthetes (across all subtypes) reported higher rates of mirror-touch and ticker tape than non-synesthetes, suggesting that synesthesia is associated with these phenomenal traits. However, effect sizes were small and we could not rule out that response bias influenced these associations. Mirror-touch and ticker tape were independent. No differences were found across gender or domain of work and study in prevalence of synesthesia, mirror-touch or ticker tape. The prevalence of ticker tape, unknown so far, was estimated at about 7%, an intermediate rate between estimates of grapheme-color (2–4%) and sequence-space synesthesia (9–14%). Within synesthesia, grapheme-personification, also called ordinal-linguistic personification (OLP) was the most common subtype and was estimated around 12%. Co-occurences of the different types of synesthesia were higher than chance, though at the level of small effect sizes. PMID

  12. Mirror-touch and ticker tape experiences in synesthesia.

    PubMed

    Chun, Charlotte A; Hupé, Jean-Michel

    2013-01-01

    A fundamental question in the field of synesthesia is whether it is associated with other cognitive phenomena. The current study examined synesthesia's connections with phenomenal traits of mirror-touch and ticker tape experiences, as well as the representation of the three phenomena in the population, across gender and domain of work/study. Mirror-touch is the automatic, involuntary experience of tactile sensation on one's own body when others are being touched. For example, seeing another person's arm being stroked can evoke physical touch sensation on one's own arm. Ticker tape is the automatic visualization of spoken words or thoughts, such as a teleprompter. For example, when spoken to, a ticker taper might see mentally the spoken words displayed in front of his face or as coming out of the speaker's mouth. To explore synesthesia's associations with these phenomena, a diverse group (n = 3743) was systematically recruited from eight universities and one public museum in France to complete an online screening. Of the 1017 eligible respondents, synesthetes (across all subtypes) reported higher rates of mirror-touch and ticker tape than non-synesthetes, suggesting that synesthesia is associated with these phenomenal traits. However, effect sizes were small and we could not rule out that response bias influenced these associations. Mirror-touch and ticker tape were independent. No differences were found across gender or domain of work and study in prevalence of synesthesia, mirror-touch or ticker tape. The prevalence of ticker tape, unknown so far, was estimated at about 7%, an intermediate rate between estimates of grapheme-color (2-4%) and sequence-space synesthesia (9-14%). Within synesthesia, grapheme-personification, also called ordinal-linguistic personification (OLP) was the most common subtype and was estimated around 12%. Co-occurences of the different types of synesthesia were higher than chance, though at the level of small effect sizes.

  13. Obituary: Gerald Frederick Tape, 1915-2005

    NASA Astrophysics Data System (ADS)

    Hughes, Robert E.

    2007-12-01

    Gerald Frederick Tape, a distinguished science statesman and administrator, died on November 20, 2005. Jerry, as he was known to all, took on many diverse and important responsibilities throughout his life and dealt with them with quiet authority and grace. This was the hallmark of his life. The Board of Trustees of Associated Universities, Inc., which he served for many years, expressed this in its condolences, writing "Jerry personified integrity, thoroughness and dedication. His sensitivity for the views of others, his sincerity, his personal commitment, his calm approach and his unfailing good humor were all greatly admired and respected." Jerry was born in Ann Arbor, Michigan on May 29, 1915 but grew up in Milan, a nearby country farm community, and in Ypsilanti where his father was Principal of Michigan State Normal College, which later became Eastern Michigan University (EMU). It was there that he first became interested in physics. It was there also that he met and courted Josephine Waffen, who later would become his wife for more than sixty-six years and fill their lives with three loving sons, Walter, James, and Thomas. Upon graduation from EMU, Jerry was awarded a scholarship that took him to the University of Michigan where he earned a Ph.D. in Physics, researching the decay modes of the radioisotopes of iodine. In the Fall of 1939, during the waning days of the Great Depression, he was offered an Instructorship in the Physics Department of Cornell University, a promising start for a fruitful academic career. He brought his bride Jo to Ithaca and joined the cyclotron group under Robert Bacher and Willy Higginbotham while devising a laboratory course in nuclear techniques for graduate students. Bacher and Higginbotham soon left Cornell to join a new wartime laboratory at the Massachusetts Institute of Technology (MIT) and many other colleagues were "drafted" for war work. Bacher persuaded Jerry to join him at the MIT Radiation Laboratory in February

  14. Graphite composite tape in beam-pumped oil wells

    SciTech Connect

    Hensley, H.N.; Tanner, C.J.

    1984-09-01

    A continuous, reelable graphite composite tape is being developed as an alternative to jointed sucker rods for use in beam pumped oil wells. Four units have been tested in wells. The composite tape is composed of graphite fibers, glass fabric, Kevlar fibers and vinylester resin. Graphite fibers have a high modulus of elasticity and provide the longitudinal stiffness needed to operate the downhole pump, while allowing a thin cross section flexible enough to be wound onto small diameter reels. This advanced graphite composite is the first practical, lightweight, reelable alternative to jointed sucker rods.

  15. The new CERN tape software - getting ready for total performance

    NASA Astrophysics Data System (ADS)

    Cano, E.; Murray, S.; Kruse, D. F.; Kotlyar, V.; Côme, D.

    2015-12-01

    CASTOR (the CERN Advanced STORage system) is used to store the custodial copy of all of the physics data collected from the CERN experiments, both past and present. CASTOR is a hierarchical storage management system that has a disk-based front-end and a tape-based back-end. The software responsible for controlling the tape back-end has been redesigned and redeveloped over the last year and was put in production at the beginning of 2015. This paper summarises the motives behind the redesign, describes in detail the redevelopment work and concludes with the short and long-term benefits.

  16. USING A TAPED INTERVENTION TO IMPROVE KINDERGARTEN STUDENTS' NUMBER IDENTIFICATION

    PubMed Central

    Krohn, Katherine R; Skinner, Christopher H; Fuller, Emily J; Greear, Corrine

    2012-01-01

    A multiple baseline design across students was used to evaluate the effects of a taped numbers (TN) intervention on the number-identification accuracy of 4 kindergarten students. During TN, students attempted to name the numbers 0 through 9 on randomized lists before each number was provided via a tape player 2 s later. All 4 students showed immediate increases and reached 100% in number-identification accuracy. One student reached 100% accuracy after TN was supplemented with performance feedback, reinforcement, and overcorrection. PMID:22844152

  17. Raman identification of drug of abuse particles collected with colored and transparent tapes.

    PubMed

    Moreno, Victor Molina; López-López, María; Atoche, Juan-Carlos; García-Ruiz, Carmen

    2014-03-01

    Raman microscopy is a useful tool for the analysis of drug particles collected with adhesive tapes. In this work, first, the spectra of thirty drugs of abuse, degradation products, metabolites, and common cutting agent standards were recorded and the Raman bands observed were summarized providing the forensic analyst useful information for the identification of drug evidence. Then, the collection of different drug particles by a fingerprint lifting tape commonly used to remove and store fingerprints and fibers, and a white and green packaging tape, followed by the subsequent identification of the drugs by confocal Raman spectroscopy was performed. The particles were analyzed on top of the tapes, trapped between glass slides and the tapes, trapped in the tape folded over itself in the case of the transparent tape, and after folding and unfolding the tape in the case of the colored tape. The results obtained by the different approaches show that both tapes did not compromise the drugs spectra. However, the use of transparent tape is preferred because this tape allows the previous visual detection of the particles. Finally, several drug and sugar particles were spread over a clean table and inside a pocket, and the particles were collected with transparent tape and then properly identified. Although good results were obtained in both cases, the amount of fibers and other substances present in the collection area made the previous detection of the particles difficult and increases the analysis time. PMID:24630328

  18. Raman identification of drug of abuse particles collected with colored and transparent tapes.

    PubMed

    Moreno, Victor Molina; López-López, María; Atoche, Juan-Carlos; García-Ruiz, Carmen

    2014-03-01

    Raman microscopy is a useful tool for the analysis of drug particles collected with adhesive tapes. In this work, first, the spectra of thirty drugs of abuse, degradation products, metabolites, and common cutting agent standards were recorded and the Raman bands observed were summarized providing the forensic analyst useful information for the identification of drug evidence. Then, the collection of different drug particles by a fingerprint lifting tape commonly used to remove and store fingerprints and fibers, and a white and green packaging tape, followed by the subsequent identification of the drugs by confocal Raman spectroscopy was performed. The particles were analyzed on top of the tapes, trapped between glass slides and the tapes, trapped in the tape folded over itself in the case of the transparent tape, and after folding and unfolding the tape in the case of the colored tape. The results obtained by the different approaches show that both tapes did not compromise the drugs spectra. However, the use of transparent tape is preferred because this tape allows the previous visual detection of the particles. Finally, several drug and sugar particles were spread over a clean table and inside a pocket, and the particles were collected with transparent tape and then properly identified. Although good results were obtained in both cases, the amount of fibers and other substances present in the collection area made the previous detection of the particles difficult and increases the analysis time.

  19. Nickel-copper alloy tapes as textured substrates for YBCO coated conductors

    NASA Astrophysics Data System (ADS)

    Vannozzi, A.; Celentano, G.; Angrisani, A.; Augieri, A.; Ciontea, L.; Colantoni, I.; Galluzzi, V.; Gambardella, U.; Mancini, A.; Petrisor, T.; Rufoloni, A.; Thalmaier, G.

    2008-02-01

    NiCuCo alloy tape was studied as textured substrates for YBCO coated conductors application. The addition of a small amount of cobalt was pursued in order to enhance the microstructure of the NiCu alloy. The use of different thermal treatments during the recrystallization process permitted to obtain area densities of cube orientation as high as 95%. The substrate was thoroughly characterized by means of x-ray diffraction, EBSD and SEM analyses. Further, the mechanical properties and the magnetic behaviour of this substrate have been investigated and compared with those exhibited by Ni, NiW and NiCu tapes. The suitability of this alloy substrate for YBCO coated conductors has been tested through the deposition of a conventional CeO2/YSZ/CeO2 buffer layer architecture using a Pd transient layer. Apart from passivating Ni-Cu-Co substrate, the use of a Pd transient layer produces a relevant texture sharpening in the out-of-plane orientation and the full width at half maximum of the ?-scan drops from about 9° of NiCuCo to 2° of Pd layer. This sharp texture is transferred to the YBCO film and the results indicate that NiCuCo alloy is a promising alternative substrate for the realization of YBCO coated conductors.

  20. 48 CFR 908.7116 - Electronic data processing tape.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... in accordance with FPMR 41 CFR 101-26.508. (b) Acquisitions of electronic data processing tape by authorized contractors shall be in accordance with FPMR 41 CFR 101-26.508-1. However, if adequate... 48 Federal Acquisition Regulations System 5 2011-10-01 2011-10-01 false Electronic data...

  1. 48 CFR 908.7116 - Electronic data processing tape.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... in accordance with FPMR 41 CFR 101-26.508. (b) Acquisitions of electronic data processing tape by authorized contractors shall be in accordance with FPMR 41 CFR 101-26.508-1. However, if adequate... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Electronic data...

  2. 75 FR 8114 - Pressure Sensitive Plastic Tape From Italy

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-23

    ..., 2009, the Commission established a schedule for the conduct of the review (74 FR 43155, August 26, 2009... From the Federal Register Online via the Government Publishing Office INTERNATIONAL TRADE COMMISSION Pressure Sensitive Plastic Tape From Italy AGENCY: United States International Trade...

  3. Astronaut Rich Clifford inserts tape into payload high data recorder

    NASA Technical Reports Server (NTRS)

    1994-01-01

    On the Space Shuttle Endeavour's aft flight deck, Astronaut Michael R. (Rich) Clifford, mission specialist, inserts a tape in the payload high rate recorder. Three of these state-of-the-art recorders captured four times the amount of data that could be radioed to the ground.

  4. Corrosion of metal particle and metal evaporated tapes

    NASA Astrophysics Data System (ADS)

    Speliotis, Dennis E.

    Very high coercivity metal particle (MP) and metal evaporated (ME) tapes are being used in 8mm video and digital audio tape applications, and more recently in digital data recording applications. In view of the inherent susceptibility of such media to environmental corrosion, a number of recent studies have addressed their long term stability and archivability. These studies have used an accelerated corrosion test based either on elevated temperature-humidity or polluting gas atmospheres known as Battelle tests. A comparison of the Battelle test results performed at different laboratories reveals a large variation from one location to another, presumably due to incorrect replication of the Battelle condition. Furthermore, when the Battelle tests are performed on enclosed cartridges, it is quite possible that diffusion limits the penetration of the extremely low concentration polluting gaseous species to the inner layers of the tapes during the short time of the accelerated test, whereas in real life these diffusion limitations may not apply. To avoid this uncertainty, the corrosion behavior of commercial 8mm MP and ME tapes when cassettes without their external plastic cases were exposed to 50 deg C and 80 percent RH for 7.5 weeks is investigated.

  5. Extendable nickel complex tapes that reach NIR absorptions.

    PubMed

    Audi, Hassib; Chen, Zhongrui; Charaf-Eddin, Azzam; D'Aléo, Anthony; Canard, Gabriel; Jacquemin, Denis; Siri, Olivier

    2014-12-14

    Stepwise synthesis of linear nickel complex oligomer tapes with no need for solid-phase support has been achieved. The control of the length in flat arrays allows a fine-tuning of the absorption properties from the UV to the NIR region.

  6. 16 CFR 1632.7 - Tape edge substitution procedure.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 16 Commercial Practices 2 2011-01-01 2011-01-01 false Tape edge substitution procedure. 1632.7 Section 1632.7 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FLAMMABLE FABRICS ACT REGULATIONS STANDARD FOR THE FLAMMABILITY OF MATTRESSES AND MATTRESS PADS (FF 4-72, AMENDED) The Standard § 1632.7...

  7. STS-46 Special Events Resource Tape, Part 1 of 2

    NASA Technical Reports Server (NTRS)

    1992-01-01

    Footage shows the inflight interviews of the crew of the STS-46 Atlantis Orbiter. An Italian VIP call and press conference (both spoken in Italian) are seen, and Mission Specialist Franklin R. Chang-Diaz participates in a Costa Rican VIP call (spoken in Spanish). See also 'STS-46 Special Events Resource Tape, Part 2 of 2'.

  8. An Important Adjunct for Counselors: Video Taped Role Playing

    ERIC Educational Resources Information Center

    Soltys, Michael P.

    1971-01-01

    Through effective use of video tape students can become better prepared for the interview, more confident and poised, and better able to relate more effectively with people. The work described in this article is related to the content of a recent CPS workshop reported in this issue. (Author)

  9. Kodak phase-change media for optical tape applications

    NASA Technical Reports Server (NTRS)

    Tyan, Yuan-Sheng; Preuss, Donald R.; Olin, George R.; Vazan, Fridrich; Pan, Kee-Chuan; Raychaudhuri, Pranab. K.

    1993-01-01

    The SbInSn phase-change write-once optical medium developed by Eastman Kodak Company is particularly suitable for development into the next generation optical tape media. Its performance for optical recording has already been demonstrated in some of the highest performance optical disk systems. Some of the key performance features are presented.

  10. A new tape product for optical data storage

    NASA Technical Reports Server (NTRS)

    Larsen, T. L.; Woodard, F. E.; Pace, S. J.

    1993-01-01

    A new tape product has been developed for optical data storage. Laser data recording is based on hole or pit formation in a low melting metallic alloy system. The media structure, sputter deposition process, and media characteristics, including write sensitivity, error rates, wear resistance, and archival storage are discussed.

  11. Contact Analog/Compressed Symbology Heading Tape Assessment

    NASA Technical Reports Server (NTRS)

    Shively, R. Jay; Atencio, Adolph; Turpin, Terry; Dowell, Susan

    2002-01-01

    A simulation assessed the performance, handling qualities and workload associated with a contact-analog, world-referenced heading tape as implemented on the Comanche Helmet Integrated Display Sight System (HIDSS) when compared with a screen-fixed, compressed heading tape. Six pilots, four active duty Army Aviators and two civilians flew three ADS-33 maneuvers and a traffic pattern in the Ames Vertical Motion Simulation facility. Small, but statistically significant advantages were found for the compressed symbology for handling qualities, workload, and some of the performance measures. It should be noted however that the level of performance and handling qualities for both symbology sets fell within the acceptable tolerance levels. Both symbology sets yield satisfactory handling qualities and performance in velocity stabilization mode and adequate handling qualities in the automatic flight control mode. Pilot comments about the contact analog symbology highlighted the lack of useful rate of change information in the heading tape and "blurring" due to the rapid movement of the heading tape. These issues warrant further study. Care must be taken in interpreting the operational significance of these results. The symbology sets yielded categorically similar data, i.e., acceptable handling qualities and adequate performance, so while the results point to the need for further study, their operational significance has yet to be determined.

  12. The Taped Monologue as Narrative Technique for Reflective Practice

    ERIC Educational Resources Information Center

    Ford, Keith

    2016-01-01

    In this article, I describe how an EFL teacher engaged in a process of reflective practice. As she looked back on her teaching career, she explored the critical incidents, principles, and practices that have informed her present teaching identity. I focus on how a taped monologue narrative technique was used, and on the rationale, practice, and…

  13. Corrosion of metal particle and metal evaporated tapes

    NASA Technical Reports Server (NTRS)

    Speliotis, Dennis E.

    1991-01-01

    Very high coercivity metal particle (MP) and metal evaporated (ME) tapes are being used in 8mm video and digital audio tape applications, and more recently in digital data recording applications. In view of the inherent susceptibility of such media to environmental corrosion, a number of recent studies have addressed their long term stability and archivability. These studies have used an accelerated corrosion test based either on elevated temperature-humidity or polluting gas atmospheres known as Battelle tests. A comparison of the Battelle test results performed at different laboratories reveals a large variation from one location to another, presumably due to incorrect replication of the Battelle condition. Furthermore, when the Battelle tests are performed on enclosed cartridges, it is quite possible that diffusion limits the penetration of the extremely low concentration polluting gaseous species to the inner layers of the tapes during the short time of the accelerated test, whereas in real life these diffusion limitations may not apply. To avoid this uncertainty, the corrosion behavior of commercial 8mm MP and ME tapes when cassettes without their external plastic cases were exposed to 50 deg C and 80 percent RH for 7.5 weeks is investigated.

  14. Flexible storage medium for write-once optical tape

    NASA Technical Reports Server (NTRS)

    Strandjord, Andrew J. G.; Webb, Steven P.; Perettie, Donald J.; Cipriano, Robert A.

    1993-01-01

    A write-once data storage media was developed which is suitable for optical tape applications. The media is manufactured using a continuous film process to deposit a ternary alloy of tin, bismuth, and copper. This laser sensitive layer is sputter deposited onto commercial plastic web as a single-layer thin film. A second layer is sequentially deposited on top of the alloy to enhance the media performance and act as an abrasion resistant hard overcoat. The media was observed to have laser write sensitivities of less than 2.0 njoules/bit, carrier-to-noise levels of greater than 50dB's, modulation depths of approximately 100 percent, read-margins of greater than 35, uniform grain sizes of less than 200 Angstroms, and a media lifetime that exceeds 10 years. Prototype tape media was produced for use in the CREO drive system. The active and overcoat materials are first sputter deposited onto three mil PET film in a single pass through the vacuum coating system, and then converted down into multiple reels of 35mm x 880m tape. One mil PET film was also coated in this manner and then slit and packaged into 3480 tape cartridges.

  15. Experimental research on tape spring supported space inflatable structures

    NASA Astrophysics Data System (ADS)

    Cook, Andrew J.; Walker, Scott J. I.

    2016-01-01

    This paper presents experimental research that continues the development of inflatable hybrid structures for space applications. Inflatables provide a concept with much scope for further incorporation into the structures of future spacecraft. They offer considerable savings in mass and stowed volume for spacecraft, providing possible reductions in satellite costs. Existing boom configurations make use of inflatables including solar arrays and the NGST sunshield. However these typically soft systems could be improved by incorporating tape springs as structural stiffeners along the length of the boom, creating hybrid structures. This research builds on previous experimental work undertaken at the University of Southampton looking at cantilever inflatable and hybrid booms. The focus of this research is to identify the structural performance improvement of adding tape springs to cantilever inflatable booms. This is achieved by tip deflection testing to determine the bending moment and rigidity performances of these structures allowing a comparison between the two technologies. Several hybrid booms are created and tested in various orientations to identify the optimal tape spring effectiveness. It was found that adding a pair of tape springs will increase stiffness of the hybrid structure by up to 4.9 times for an increase of 2.4 times the boom mass.

  16. STS 110 Mission Highlights Resource Tape. Part 2 of 4

    NASA Technical Reports Server (NTRS)

    2002-01-01

    A continuation of 'STS 110 Mission Highlights Resource Tape'. This video, Part 2 of 4, shows footage from flight days 3 through 5 of STS-110. The flight crew includes Michael J. Bloomfield, Commander; Stephen N. Frick, Pilot; Jerry L. Ross, Mission Specialist; Steven L. Smith, Mission Specialist; Ellen Ochoa, Mission Specialist; Lee M.E. Morin, Mission Specialist; Rex J. Walheim, Mission Specialist. The coverage from flight day 3 includes docking replays of Atlantis and the International Space Station (ISS), and postdocking procedures, as well as intermingling of the flight crew with the Expedition 4 crew (Yury I. Onufrienko, Commander; Daniel W. Bursch, Flight Engineer; Carl E. Walz, Flight Engineer) of the ISS. Flight day 4 includes an EVA (extravehicular activity) in which Walheim and Smith lift the S0 Truss from the payload bay, and temporarily clamp it onto the Destiny laboratory. On flight day 5 a suite of spaceborne experiments (not shown) arrives at Destiny, including protein crystal growth and wheat plant growth experiments. Notable footage includes Hawaii, New Zealand, and sunrise on Atlantis. An unknown object steaks across the field of view during the video, with the Earth in the background. The activities of the other flight days can be seen on 'STS 110 Mission Highlights Resource Tape, Part 1 of 4' (internal ID 2002137575), 'STS 110 Mission Highlights Resource Tape, Part 3 of 4' (internal ID 2002137574), and 'STS 110 Mission Highlights Resource Tape, Part 4 of 4' (internal ID 2002137517).

  17. Privacy: The Reporter, the Telephone, and the Tape Recorder.

    ERIC Educational Resources Information Center

    Riley, Sam G.; Wiessler, Joel M.

    Federal and state law provides, for the most part, little specific guidance to persons tape recording their own telephone calls for their own record-keeping purposes. In a specific case, a Pennsylvania newsman was prosecuted in 1972 on charges of wiretapping his own telephone conversations without notice to the other parties in the calls. A review…

  18. [Recovery of blood traces with scenesafe FAST tape].

    PubMed

    Keller, Eva; Looser, Markus; Bieri, Hans-Peter; Kübler, Eric; Balitzki, Beate

    2012-01-01

    For complete and conclusive DNA profiling a sufficient amount of DNA must be available. For that, biological traces are recovered from crime scenes using special trace recovery material. The current method to collect biological traces for DNA analysis is to wipe them off with cotton swabs. However, for a few years the use of adhesive tapes has also been described for the recovery of evidence. In 2009, an adhesive tape was launched which was specially developed for the collection of biological traces. This product called Scenesafe FAST Tape (SSF) was investigated in this work to give recommendations for its use in evidence recovery. The results of this work show that the DNA can be extracted from the SSF very well. However, the tapes seem less suitable for direct use at the crime scene, as they are not flexible enough for adaptation to different crime scene conditions and the risk of contamination is higher than when collecting evidence with cotton swabs. Neither SSF nor cotton swabs are optimal for all requirements. The best method to recover biological evidence is still dependent on the surface material and the circumstances at the crime scene.

  19. Extendable nickel complex tapes that reach NIR absorptions.

    PubMed

    Audi, Hassib; Chen, Zhongrui; Charaf-Eddin, Azzam; D'Aléo, Anthony; Canard, Gabriel; Jacquemin, Denis; Siri, Olivier

    2014-12-14

    Stepwise synthesis of linear nickel complex oligomer tapes with no need for solid-phase support has been achieved. The control of the length in flat arrays allows a fine-tuning of the absorption properties from the UV to the NIR region. PMID:25348258

  20. 16 CFR 1632.7 - Tape edge substitution procedure.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Tape edge substitution procedure. 1632.7 Section 1632.7 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FLAMMABLE FABRICS ACT REGULATIONS STANDARD FOR THE FLAMMABILITY OF MATTRESSES AND MATTRESS PADS (FF 4-72, AMENDED) The Standard § 1632.7...

  1. Superconducting magnet

    DOEpatents

    Satti, John A.

    1980-01-01

    A superconducting magnet designed to produce magnetic flux densities of the order of 4 to 5 Webers per square meter is constructed by first forming a cable of a plurality of matrixed superconductor wires with each wire of the plurality insulated from each other one. The cable is shaped into a rectangular cross-section and is wound with tape in an open spiral to create cooling channels. Coils are wound in a calculated pattern in saddle shapes to produce desired fields, such as dipoles, quadrupoles, and the like. Wedges are inserted between adjacent cables as needed to maintain substantially radial placement of the long dimensions of cross sections of the cables. After winding, individual strands in each of the cables are brought out to terminals and are interconnected to place all of the strands in series and to maximize the propagation of a quench by alternating conduction from an inner layer to an outer layer and from top half to bottom half as often as possible. Individual layers are separated from others by spiraled aluminum spacers to facilitate cooling. The wound coil is wrapped with an epoxy tape that is cured by heat and then machined to an interference fit with an outer aluminum pipe which is then affixed securely to the assembled coil by heating it to make a shrink fit. In an alternate embodiment, one wire of the cable is made of copper or the like to be heated externally to propagate a quench.

  2. Playback Station #2 for Cal Net and 5-day-recorder tapes

    USGS Publications Warehouse

    Eaton, Jerry P.

    1978-01-01

    A second system (Playback Station #2) has been set up to play back Cal Net 1" tapes and 5-day-recorder 1/2" tapes. As with the first playback system (Playback Station #1) the tapes are played back on a Bell and Howell VR3700B tape deck and the records are written out on a 16-channel direct-writing Siemens "0scillomink." Separate reproduce heads, tape guides, and tape tension sensor rollers are required for playing back 111 tapes and 1/2" tapes, but changing these tape deck components is a simple task that requires only a few minutes. The discriminators, patch panels, selector switches, filters, time code translators, and signal conditioning circuits for the time code translators and for the tape-speed-compensation signal are all mounted in an equipment rack that stands beside the playback tape deck. Changing playback speeds (15/16 ips or 3 3/4 ips) or changing from Cal Net tapes to 5-day-recorder tapes requires only flipping a few switches and/or changing a few patch cables on the patch panel (in addition to changing the reproduce heads, etc., to change from 1" tape to 1/2" tape). For the Cal Net tapes, the system provides for playback of 9 data channels (680 Hz thru 3060 Hz plus 400 Hz) and 3 time signals (IRIG-E, IRIG-C, and WWVB) at both 15/16 ips (x1 speed) and 3 3/4 ips (x4 speed). Available modes of compensation (using either a 4688 Hz reference or a 3125 Hz reference) are subtractive, capstan, capstan plus subtractive, or no compensation.

  3. Generation and physical characteristics of the Landsat 1 and 2 MSS computer compatible tapes

    NASA Technical Reports Server (NTRS)

    Thomas, V. L.

    1975-01-01

    The generation and format is discussed of the Landsat 1 and 2 system corrected multispectral scanner computer compatible tapes. Included in the discussion are the spacecraft sensors, scene characteristics, the transmission of data, and the conversion of the data to computer compatible tapes at the NASA Data Processing Facility. Geometric and radiometric corrections, tape formats, and the physical characteristics of the tape are also described.

  4. Apparatus and method for loading and unloading multiple digital tape cassettes utilizing a removable magazine

    DOEpatents

    Lindenmeyer, C.W.

    1993-01-26

    An apparatus and method to automate the handling of multiple digital tape cassettes for processing by commercially available cassette tape readers and recorders. A removable magazine rack stores a plurality of tape cassettes, and cooperates with a shuttle device that automatically inserts and removes cassettes from the magazine to the reader and vice-versa. Photocells are used to identify and index to the desired tape cassette. The apparatus allows digital information stored on multiple cassettes to be processed without significant operator intervention.

  5. Apparatus and method for loading and unloading multiple digital tape cassettes utilizing a removable magazine

    DOEpatents

    Lindenmeyer, Carl W.

    1993-01-01

    An apparatus and method to automate the handling of multiple digital tape cassettes for processing by commercially available cassette tape readers and recorders. A removable magazine rack stores a plurality of tape cassettes, and cooperates with a shuttle device that automatically inserts and removes cassettes from the magazine to the reader and vice-versa. Photocells are used to identify and index to the desired tape cassette. The apparatus allows digital information stored on multiple cassettes to be processed without significant operator intervention.

  6. Magneto-optical imaging of magnetic domain pattern produced by intense femtosecond laser pulse irradiation

    NASA Astrophysics Data System (ADS)

    Sinha, Jaivarhan; Mohan, Shyam; Banerjee, S. S.; Kahaly, S.; Kumar, G. Ravindra

    2009-03-01

    An important and intriguing area of research is laser plasma generated giant magnetic field pulses. Interaction of ultrashort high intensity laser pulses with matter involves several mechanisms for generating ultrastrong magnetic fields. By irradiating a magnetic recordable tape constituting of γ-Fe2O3 particles with an intense p-polarized femtosecond laser pulses (˜ 10^16 W cm-2, 100fs), we have found complex magnetic field patterns stored in the tape. We image the local magnetic field distribution around the irradiated region [1] using the high sensitivity magneto-optical imaging technique. We understand the complex magnetic domains patterns recoded on the tape in terms of interesting instabilities [1] generated in the plasma produced during the irradiation of the tape with intense laser pulses. [0pt] [1] Jaivardhan Sinha, Shyam Mohan, S. S Banerjee, S. Kahaly, G. Ravindra Kumar, Phys. Rev. E 77, 046118(2008). *satyajit@iitk.ac.in

  7. High-throughput DNA extraction of forensic adhesive tapes.

    PubMed

    Forsberg, Christina; Jansson, Linda; Ansell, Ricky; Hedman, Johannes

    2016-09-01

    Tape-lifting has since its introduction in the early 2000's become a well-established sampling method in forensic DNA analysis. Sampling is quick and straightforward while the following DNA extraction is more challenging due to the "stickiness", rigidity and size of the tape. We have developed, validated and implemented a simple and efficient direct lysis DNA extraction protocol for adhesive tapes that requires limited manual labour. The method uses Chelex beads and is applied with SceneSafe FAST tape. This direct lysis protocol provided higher mean DNA yields than PrepFiler Express BTA on Automate Express, although the differences were not significant when using clothes worn in a controlled fashion as reference material (p=0.13 and p=0.34 for T-shirts and button-down shirts, respectively). Through in-house validation we show that the method is fit-for-purpose for application in casework, as it provides high DNA yields and amplifiability, as well as good reproducibility and DNA extract stability. After implementation in casework, the proportion of extracts with DNA concentrations above 0.01ng/μL increased from 71% to 76%. Apart from providing higher DNA yields compared with the previous method, the introduction of the developed direct lysis protocol also reduced the amount of manual labour by half and doubled the potential throughput for tapes at the laboratory. Generally, simplified manual protocols can serve as a cost-effective alternative to sophisticated automation solutions when the aim is to enable high-throughput DNA extraction of complex crime scene samples. PMID:27448236

  8. High-throughput DNA extraction of forensic adhesive tapes.

    PubMed

    Forsberg, Christina; Jansson, Linda; Ansell, Ricky; Hedman, Johannes

    2016-09-01

    Tape-lifting has since its introduction in the early 2000's become a well-established sampling method in forensic DNA analysis. Sampling is quick and straightforward while the following DNA extraction is more challenging due to the "stickiness", rigidity and size of the tape. We have developed, validated and implemented a simple and efficient direct lysis DNA extraction protocol for adhesive tapes that requires limited manual labour. The method uses Chelex beads and is applied with SceneSafe FAST tape. This direct lysis protocol provided higher mean DNA yields than PrepFiler Express BTA on Automate Express, although the differences were not significant when using clothes worn in a controlled fashion as reference material (p=0.13 and p=0.34 for T-shirts and button-down shirts, respectively). Through in-house validation we show that the method is fit-for-purpose for application in casework, as it provides high DNA yields and amplifiability, as well as good reproducibility and DNA extract stability. After implementation in casework, the proportion of extracts with DNA concentrations above 0.01ng/μL increased from 71% to 76%. Apart from providing higher DNA yields compared with the previous method, the introduction of the developed direct lysis protocol also reduced the amount of manual labour by half and doubled the potential throughput for tapes at the laboratory. Generally, simplified manual protocols can serve as a cost-effective alternative to sophisticated automation solutions when the aim is to enable high-throughput DNA extraction of complex crime scene samples.

  9. Comparison of Medical Adhesive Tapes in Patients at Risk of Facial Skin Trauma under Anesthesia

    PubMed Central

    Lie, Sui An; Chong, Shin Yuet

    2016-01-01

    Introduction. Adhesive tapes are used for taping eyelids closed and securing endotracheal tubes during general anesthesia. These tapes can cause facial skin injury. We compared the incidence of facial skin injury and patient satisfaction with different tapes used. Methods. A total of 60 adult patients at risk of skin trauma were randomized to use 3M™ Kind Removal Silicone Tape or standard acrylate tapes: 3M Durapore (endotracheal tube) and Medipore (eyelids). Patients were blinded to tape used. Postoperatively, a blinded recovery nurse assessed erythema, edema, and denudation of skin. Anesthesiologist in charge also assessed skin injury. On postoperative day 1, patients rated satisfaction with the condition of their skin over the eyelids and face on a 5-point Likert scale. Results. More patients had denudation of skin with standard tapes, 4 (13.3%) versus 0 with silicone tape (p = 0.026) and in anesthesiologist-evaluated skin injury 11 (37%) with standard versus 1 (3%) with silicone (p = 0.002). No significant differences were found in erythema and edema. Patient satisfaction score was higher with silicone tape: over eyelids: mean 3.83 (standard) versus 4.53 (silicone), Mann-Whitney U test, p < 0.001; over face: mean 3.87 (standard) versus 4.57 (silicone) (p < 0.001). Conclusion. Silicone tape use had less skin injury and greater patient satisfaction than standard acrylate tapes. PMID:27382368

  10. Effect of two different kinesio taping techniques on knee kinematics and kinetics in young females

    PubMed Central

    Guner, Senem; Alsancak, Serap; Koz, Mitat

    2015-01-01

    [Purpose] The application of kinesio taping may improve strength and performance, inhibit and facilitate motor activity, and increase range of motion. The aim of this study was to compare the effects of kinesio taping facilitation and inhibition applications on spatiotemporal knee kinematics and kinetics during walking activity in healthy subjects. [Subjects and Methods] A three-dimensional quantitative gait evaluation was performed without tape and with, facilitation and inhibition kinesio taping application on the knee. Sixteen healthy female college students (age, 19.7 ± 0.4 years; height, 1.64 ± 3.4 cm; body mass, 51.5 ± 4.8 kg) participated in the study. [Results] Spatiotemporal parameters (cadence, walking speed, stride length) were significantly different among the trials. Knee joint sagittal plane range of motion was not different with either kinesio taping application. Knee external flexion moment during the early stance phase decreased significantly with facilitation kinesio taping and increased with the inhibition kinesio taping. Knee external extension moment during the mid-stance phase increased with facilitation kinesio taping. Knee power parameters, eccentric activity in the rectus femoris during the pre-swing phase was significantly increased with inhibition kinesio taping application, while eccentric activity of the hamstrings during the terminal swing of gait was decreased. [Conclusion] These findings showed that facilitation kinesio taping application affected the terminal stance phase and that inhibition kinesio taping influenced the terminal swing phase compared with the no tape condition. PMID:26644651

  11. 21 CFR 880.5240 - Medical adhesive tape and adhesive bandage.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Medical adhesive tape and adhesive bandage. 880... Personal Use Therapeutic Devices § 880.5240 Medical adhesive tape and adhesive bandage. (a) Identification. A medical adhesive tape or adhesive bandage is a device intended for medical purposes that...

  12. 21 CFR 880.5240 - Medical adhesive tape and adhesive bandage.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Medical adhesive tape and adhesive bandage. 880... Personal Use Therapeutic Devices § 880.5240 Medical adhesive tape and adhesive bandage. (a) Identification. A medical adhesive tape or adhesive bandage is a device intended for medical purposes that...

  13. 21 CFR 880.5240 - Medical adhesive tape and adhesive bandage.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Medical adhesive tape and adhesive bandage. 880... Personal Use Therapeutic Devices § 880.5240 Medical adhesive tape and adhesive bandage. (a) Identification. A medical adhesive tape or adhesive bandage is a device intended for medical purposes that...

  14. 21 CFR 880.5240 - Medical adhesive tape and adhesive bandage.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Medical adhesive tape and adhesive bandage. 880... Personal Use Therapeutic Devices § 880.5240 Medical adhesive tape and adhesive bandage. (a) Identification. A medical adhesive tape or adhesive bandage is a device intended for medical purposes that...

  15. The Effects of Audio Tapes on Graduate Student Performance and Attitudes

    ERIC Educational Resources Information Center

    Barringer, Robert; Bekiroglu, Haluk

    1978-01-01

    This is an analysis of the use of audio tapes in an introductory operations research course for off-campus MBA students. The tapes seemed to improve the exam scores of those students who used them. Students who used the tapes more extensively seemed to enjoy a greater advantage. (Author/IRT)

  16. Effect of two different kinesio taping techniques on knee kinematics and kinetics in young females.

    PubMed

    Guner, Senem; Alsancak, Serap; Koz, Mitat

    2015-10-01

    [Purpose] The application of kinesio taping may improve strength and performance, inhibit and facilitate motor activity, and increase range of motion. The aim of this study was to compare the effects of kinesio taping facilitation and inhibition applications on spatiotemporal knee kinematics and kinetics during walking activity in healthy subjects. [Subjects and Methods] A three-dimensional quantitative gait evaluation was performed without tape and with, facilitation and inhibition kinesio taping application on the knee. Sixteen healthy female college students (age, 19.7 ± 0.4 years; height, 1.64 ± 3.4 cm; body mass, 51.5 ± 4.8 kg) participated in the study. [Results] Spatiotemporal parameters (cadence, walking speed, stride length) were significantly different among the trials. Knee joint sagittal plane range of motion was not different with either kinesio taping application. Knee external flexion moment during the early stance phase decreased significantly with facilitation kinesio taping and increased with the inhibition kinesio taping. Knee external extension moment during the mid-stance phase increased with facilitation kinesio taping. Knee power parameters, eccentric activity in the rectus femoris during the pre-swing phase was significantly increased with inhibition kinesio taping application, while eccentric activity of the hamstrings during the terminal swing of gait was decreased. [Conclusion] These findings showed that facilitation kinesio taping application affected the terminal stance phase and that inhibition kinesio taping influenced the terminal swing phase compared with the no tape condition. PMID:26644651

  17. Effect of two different kinesio taping techniques on knee kinematics and kinetics in young females.

    PubMed

    Guner, Senem; Alsancak, Serap; Koz, Mitat

    2015-10-01

    [Purpose] The application of kinesio taping may improve strength and performance, inhibit and facilitate motor activity, and increase range of motion. The aim of this study was to compare the effects of kinesio taping facilitation and inhibition applications on spatiotemporal knee kinematics and kinetics during walking activity in healthy subjects. [Subjects and Methods] A three-dimensional quantitative gait evaluation was performed without tape and with, facilitation and inhibition kinesio taping application on the knee. Sixteen healthy female college students (age, 19.7 ± 0.4 years; height, 1.64 ± 3.4 cm; body mass, 51.5 ± 4.8 kg) participated in the study. [Results] Spatiotemporal parameters (cadence, walking speed, stride length) were significantly different among the trials. Knee joint sagittal plane range of motion was not different with either kinesio taping application. Knee external flexion moment during the early stance phase decreased significantly with facilitation kinesio taping and increased with the inhibition kinesio taping. Knee external extension moment during the mid-stance phase increased with facilitation kinesio taping. Knee power parameters, eccentric activity in the rectus femoris during the pre-swing phase was significantly increased with inhibition kinesio taping application, while eccentric activity of the hamstrings during the terminal swing of gait was decreased. [Conclusion] These findings showed that facilitation kinesio taping application affected the terminal stance phase and that inhibition kinesio taping influenced the terminal swing phase compared with the no tape condition.

  18. The effectiveness of kinesio taping for athletes with medial elbow epicondylar tendinopathy.

    PubMed

    Chang, H-Y; Cheng, S-C; Lin, C-C; Chou, K-Y; Gan, S-M; Wang, C-H

    2013-11-01

    Kinesio taping has also been used for athletes with Medial Elbow Epicondylar Tendinopathy (MET) as an additional treatment method. The purpose of this study was to determine the clinical effectiveness of Kinesio tape on maximal grip strength and absolute and related force sense in athletes with MET when applied to the medial forearm. 27 male athletes who voluntarily participated in this study were divided into a healthy group (n=17) and a MET group (n=10). All subjects were assessed for the maximal grip strength and grip force sense (absolute and related force sense) under 3 taping conditions: 1) without taping; 2) with placebo Kinesio taping; and 3) with Kinesio taping. No significant interaction was found between groups and taping condition in maximal grip force and related force sense error, except for absolute force sense error (p=0.04). Both groups with absolute force sense measurements had significantly decreased errors in the placebo Kinesio taping and Kinesio taping conditions. Both taping may enhance discrimination of magnitude of grip force control (absolute force sense) in both groups when applied to the forearm. However, Kinesio taping did not change maximal grip strength in either group. The effects of Kinesio taping on other muscle functions remain to be studied.

  19. Report of the Tape Recorder Action Plan Committee, 21 March 1972

    NASA Technical Reports Server (NTRS)

    1972-01-01

    A NASA/AF Tape Recorder Action Plan Committee was formed in January 1972 to investigate tape recorder problems and to recommend an action plan to NASA management. The committee collected data on tape recorder failure history, pinpointed problem areas, discussed needed technical and management changes, and proposed an action plan for the recommended approaches.

  20. Compact Translating-Head Magnetic Memories

    NASA Technical Reports Server (NTRS)

    Katti, Romney R.

    1992-01-01

    Stationary magnetic media stores information at densities up to 6.5 Gb/cm(Sup 2). High-density memory devices combine features of advanced rotating-disk magnetic recording and playback systems with compact two-axis high-acceleration linear actuators. New devices weigh less, occupy less space, and consume less power than disk and tape recorders.

  1. ‘Defect-irrelevant’ behavior of a no-insulation pancake coil wound with REBCO tapes containing multiple defects

    NASA Astrophysics Data System (ADS)

    Hahn, Seungyong; Radcliff, Kyle; Kim, Kwanglok; Kim, Seokho; Hu, Xinbo; Kim, Kwangmin; Abraimov, Dmytro V.; Jaroszynski, Jan

    2016-10-01

    A no-insulation (NI) pancake coil was wound with a 23 m long REBCO tape containing multiple ‘defects’, at which local critical currents are substantially lower (<80%) than the tape’s lengthwise average. During a charging test up to 60 A in a bath of liquid nitrogen at 77 K, the test coil showed ‘defect-irrelevant’ behaviors, i.e. coil terminal voltages and center fields in steady-state operations were barely discernible from those of an ideal ‘defect-free’ coil. Also, the critical current (I c) of the coil was measured to be 68 A, close to 72 A estimated from the measured I c angular dependency data of a defect-free sample tape that was used for construction of the coil. The results demonstrate a potential to build a pancake coil with REBCO tapes regardless of their defects, which may lead to a substantial reduction in the construction cost of high field NI REBCO magnets.

  2. Transport and AC loss properties of the repaired multifilamentary REBCO superconducting tapes

    NASA Astrophysics Data System (ADS)

    Yamasaki, S.; Iwakuma, M.; Funaki, K.; Kato, J.; Chikumoto, T.; Tanabe, K.; Nakao, K.; Izumi, T.; Yamada, Y.; Shiohara, Y.; Saito, T.

    2010-11-01

    For near-future applications of REBa 2Cu 3O 7 (REBCO) coated conductors to electric power cables, transformers and Superconducting Magnetic Energy Storage (SMES), the long taped wires with high performance in the transport properties have been designed and fabricated. Moreover, in order to drastically reduce AC losses in perpendicular field configuration, advanced multifilament YBCO coated conductors (MFYCCs) fabricated with technique of a laser scribing process have been also developed. In the present study, from engineering viewpoints to utilize such advanced conductors, we evaluated the transport and AC loss properties of short MFYCCs with a repaired part or a joint by a diffusion joint technique with the saddle-shaped pickup coil method.

  3. Effect of the Kinesio tape to muscle activity and vertical jump performance in healthy inactive people

    PubMed Central

    2011-01-01

    Background Elastic taping applied on the triceps surae has been commonly used to improve the performance of lower extremities. However, little objective evidence has been documented. The purpose of this study was to investigate the effect of elastic taping on the triceps surae during a maximal vertical jump. It was hypothesized that elastic taping to the triceps surae would increase muscle activity and cause positive effect to jump height. Methods Thirty-one healthy adults (19 males and 12 females with mean age, body weight and height for 25.3 ± 3.8 years old, 64.1 ± 6.2 kg, and 169.4 ± 7.3 cm, respectively) were recruited. All participants performed vertical jump tests prior to (without taping) and during elastic taping. Two elastic tapes, Kinesio tape and Mplacebo tape from two different manufacturers, were applied to the participants, respectively. Results The results showed that the vertical ground reaction force increased when Kinesio tape was applied even when the height of jump remained about constant. However, the height of the jump decreased, and there was no difference on the vertical ground reaction force in Mplacebo taping group. Although the EMG activity of medial gastrocnemius tended to increase in Kinesio taping group, we did not see differences in EMG activity for the medial gastrocnemius, tibialis anterior and soleus muscles in either group. Conclusions Based on the varied effects of Kinesio tape and Mplacebo tape, different intervention technique was suggested for specific purpose during vertical jump movement. Mplacebo tape was demanded for the benefits of stabilization, protection, and the restriction of motion at the ankle joint. On the other hand, the findings may implicate benefits for medial gastrocnemius muscle strength and push-off force when using Kinesio tape. PMID:21831321

  4. Segmented superconducting tape having reduced AC losses and method of making

    DOEpatents

    Foltyn, Stephen R.; Jia, Quanxi; Arendt, Paul N.; Holesinger, Terry G.; Wang, Haiyan

    2009-09-22

    A superconducting tape having reduced AC losses. The tape has a high temperature superconductor layer that is segmented. Disruptive strips, formed in one of the tape substrate, a buffer layer, and the superconducting layer create parallel discontinuities in the superconducting layer that separate the current-carrying elements of the superconducting layer into strips or filament-like structures. Segmentation of the current-carrying elements has the effect of reducing AC current losses. Methods of making such a superconducting tape and reducing AC losses in such tapes are also disclosed.

  5. High-definition tape-to-film transfer

    NASA Astrophysics Data System (ADS)

    Helt, Francois

    1992-08-01

    With the collaboration of Thomson Broadcast Ex Machina has developed a full digital tape-to-film transfer process. This system accepts as input any European Analog or Digital formats: 1 inch B. T. S. 4xDl. . . It is based on a fully computerized image processing and is fully automated from the loading of the Dl tapes to the 35mm negative output. This process includes spatial and temporal filtering to get full scan 35 mmimage quality. As the input format is 50 fields per second (non-square pixels) and the output format is 24 frames per second (square pixels) the key point was to obtain a good spatial resolution without dynamic artefacts like excessive blur moving images or patterns at vertical edges. Steps of the process are as follows: - Digital copy on four 4:2:2 tapes as necessary - Transfer on computer network - Adaptive filtering by software - Gamma correction and output on 35mmfilm recorder. The processing speed has been improved by controlling four processes in parallel. High Definition tape to film transfer is available right now. The transfer capacity is 30 minutes per week since the end of last year. 1 - PRESENTATION OF THE PROJECT With the collaboration of THOMSON Broadcast Ex Machina has developed a fully digital High Definition tape-to-film transfer process. This sytem is designed to permit transfer on 35mm film of productions made with the European High Definition Standard. As a computer graphics production company Ex Machina has been producing sequences on various media including digital video high definition video 35 mm film and has finished recently a 3 mn film on 70 mm IMAX format. Two ongoing projects use this same standard with one having been designed for stereoscopic projection. Building on this expertise Ex Machina proposed to realize a tape to film transfer system for the European Economic Interest Grouping (EIIG) Vision 1250 in co-operation with another european organisation Eureka 95. For the development of such a system the company

  6. Magnetization ac loss reduction in HTS CORC® cables made of striated coated conductors

    NASA Astrophysics Data System (ADS)

    Vojenčiak, M.; Kario, A.; Ringsdorf, B.; Nast, R.; van der Laan, D. C.; Scheiter, J.; Jung, A.; Runtsch, B.; Gömöry, F.; Goldacker, W.

    2015-10-01

    High temperature superconductors (HTSs), like for instance REBCO (RE = rare earth) coated conductors, are of high potential for building large superconducting magnets. Some magnets, such as accelerator magnets, require the use of superconducting cables to allow fast ramping, and low magnetization loss to mitigate field quality issues. One of the methods to lower ac loss is to divide the superconducting layer in the tape into filaments. In this paper, conductors with copper stabilization for practical applications are laser scribed into narrow filaments. Striated tapes are then wound into conductor on round core (CORC®) cables. The critical current and magnetization ac loss of single tapes were measured. We found that the stabilizing copper layer causes difficulties for laser scribing. The degradation of the critical current is more pronounced than in the case of non-stabilized tapes. The selection of the number of filaments is therefore a compromise between critical current degradation and reduction of ac loss. Based on the results obtained from single tape experiments, the optimum number of filaments in 4 mm wide tapes was chosen, and CORC® cables with 2, 3 and 4 layers of tapes with and without filaments were manufactured. Magnetization ac loss measurements at 77 K showed a reduction of ac loss in the cables with filaments. This reduction corresponds almost to the number of filaments. Measurement at different frequencies also showed that the coupling loss in CORC® cables with a short twist-pitch is relatively small in comparison to hysteretic loss.

  7. The effects of trunk kinesio taping on balance ability and gait function in stroke patients

    PubMed Central

    Lee, Yang Jin; Kim, Ji Young; Kim, Seong Yoel; Kim, Kyung Hoon

    2016-01-01

    [Purpose] Kinesio taping is a therapeutic method used in the treatment of various musculoskeletal and neuromuscular deficits, but there is limited evidence of the effects of trunk kinesio taping in neurologic patients. Therefore, this study aimed to determine the effects of trunk kinesio taping on balance ability and gait function in persons after a stroke. [Subjects and Methods] Twenty-five post-stroke patients were included in this study. Kinesio tape was applied to four trunk muscles. Before and after the taping, in all subjects, the balance ability was measured using the Wii Balance Board, and gait function was assessed using the GAITRite system. [Results] The difference in gait function before and after trunk taping was not statistically significant. However, a variability of balance ability showed statistically significant differences. [Conclusion] These results suggest that taping may be a helpful method during rehabilitation programs for stroke patients. Its application to the trunk muscles is especially useful for improving balance ability.

  8. The effects of trunk kinesio taping on balance ability and gait function in stroke patients

    PubMed Central

    Lee, Yang Jin; Kim, Ji Young; Kim, Seong Yoel; Kim, Kyung Hoon

    2016-01-01

    [Purpose] Kinesio taping is a therapeutic method used in the treatment of various musculoskeletal and neuromuscular deficits, but there is limited evidence of the effects of trunk kinesio taping in neurologic patients. Therefore, this study aimed to determine the effects of trunk kinesio taping on balance ability and gait function in persons after a stroke. [Subjects and Methods] Twenty-five post-stroke patients were included in this study. Kinesio tape was applied to four trunk muscles. Before and after the taping, in all subjects, the balance ability was measured using the Wii Balance Board, and gait function was assessed using the GAITRite system. [Results] The difference in gait function before and after trunk taping was not statistically significant. However, a variability of balance ability showed statistically significant differences. [Conclusion] These results suggest that taping may be a helpful method during rehabilitation programs for stroke patients. Its application to the trunk muscles is especially useful for improving balance ability. PMID:27630439

  9. The effects of trunk kinesio taping on balance ability and gait function in stroke patients.

    PubMed

    Lee, Yang Jin; Kim, Ji Young; Kim, Seong Yoel; Kim, Kyung Hoon

    2016-08-01

    [Purpose] Kinesio taping is a therapeutic method used in the treatment of various musculoskeletal and neuromuscular deficits, but there is limited evidence of the effects of trunk kinesio taping in neurologic patients. Therefore, this study aimed to determine the effects of trunk kinesio taping on balance ability and gait function in persons after a stroke. [Subjects and Methods] Twenty-five post-stroke patients were included in this study. Kinesio tape was applied to four trunk muscles. Before and after the taping, in all subjects, the balance ability was measured using the Wii Balance Board, and gait function was assessed using the GAITRite system. [Results] The difference in gait function before and after trunk taping was not statistically significant. However, a variability of balance ability showed statistically significant differences. [Conclusion] These results suggest that taping may be a helpful method during rehabilitation programs for stroke patients. Its application to the trunk muscles is especially useful for improving balance ability.

  10. An Improvement in Thermal Modelling of Automated Tape Placement Process

    SciTech Connect

    Barasinski, Anaies; Leygue, Adrien; Poitou, Arnaud; Soccard, Eric

    2011-01-17

    The thermoplastic tape placement process offers the possibility of manufacturing large laminated composite parts with all kinds of geometries (double curved i.e.). This process is based on the fusion bonding of a thermoplastic tape on a substrate. It has received a growing interest during last years because of its non autoclave abilities.In order to control and optimize the quality of the manufactured part, we need to predict the temperature field throughout the processing of the laminate. In this work, we focus on a thermal modeling of this process which takes in account the imperfect bonding existing between the different layers of the substrate by introducing thermal contact resistance in the model. This study is leaning on experimental results which inform us that the value of the thermal resistance evolves with temperature and pressure applied on the material.

  11. Development of an alternating flat to tubular Kevlar parachute tape

    SciTech Connect

    Ericksen, R.H.; Koch, R.

    1989-01-01

    An alternating flat to tubular Kevlar tape was developed to replace braided suspension lines and woven tape radials on the new crew escape module parachute system for the F-111 aircraft. Weaves were developed which had high strength efficiency and low weight throughout the flat, tubular, and transition sections. A tubular section strength of 535 lbs at a weight of 0.044 oz/yd was achieved. This reduces suspension line weight by 8% compared with that of the most efficient braid which has a strength of 470 lbs and weighs 0.048 oz/yd. Length measuring procedures for production control and inspection were developed. Using these procedures it was possible to produce alternating weave fabric with less than 1% variation in length in the tubular sections. 3 refs., 4 figs., 3 tabs.

  12. TM digital image products for applications. [computer compatible tapes

    NASA Technical Reports Server (NTRS)

    Barker, J. L.; Gunther, F. J.; Abrams, R. B.; Ball, D.

    1984-01-01

    The image characteristics of digital data generated by LANDSAT 4 thematic mapper (TM) are discussed. Digital data from the TM resides in tape files at various stages of image processing. Within each image data file, the image lines are blocked by a factor of either 5 for a computer compatible tape CCT-BT, or 4 for a CCT-AT and CCT-PT; in each format, the image file has a different format. Nominal geometric corrections which provide proper geodetic relationships between different parts of the image are available only for the CCT-PT. It is concluded that detector 3 of band 5 on the TM does not respond; this channel of data needs replacement. The empty bin phenomenon in CCT-AT images results from integer truncations of mixed-mode arithmetric operations.

  13. An Improvement in Thermal Modelling of Automated Tape Placement Process

    NASA Astrophysics Data System (ADS)

    Barasinski, Anaïs; Leygue, Adrien; Soccard, Eric; Poitou, Arnaud

    2011-01-01

    The thermoplastic tape placement process offers the possibility of manufacturing large laminated composite parts with all kinds of geometries (double curved i.e.). This process is based on the fusion bonding of a thermoplastic tape on a substrate. It has received a growing interest during last years because of its non autoclave abilities. In order to control and optimize the quality of the manufactured part, we need to predict the temperature field throughout the processing of the laminate. In this work, we focus on a thermal modeling of this process which takes in account the imperfect bonding existing between the different layers of the substrate by introducing thermal contact resistance in the model. This study is leaning on experimental results which inform us that the value of the thermal resistance evolves with temperature and pressure applied on the material.

  14. Nimbus-7 ERB Solar Analysis Tape (ESAT) user's guide

    NASA Technical Reports Server (NTRS)

    Major, Eugene; Hickey, John R.; Kyle, H. Lee; Alton, Bradley M.; Vallette, Brenda J.

    1988-01-01

    Seven years and five months of Nimbus-7 Earth Radiation Budget (ERB) solar data are available on a single ERB Solar Analysis Tape (ESAT). The period covered is November 16, 1978 through March 31, 1986. The Nimbus-7 satellite performs approximately 14 orbits per day and the ERB solar telescope observes the sun once per orbit as the satellite crosses the southern terminator. The solar data were carefully calibrated and screened. Orbital and daily mean values are given for the total solar irradiance plus other spectral intervals (10 solar channels in all). In addition, selected solar activity indicators are included on the ESAT. The ESAT User's Guide is an update of the previous ESAT User's Guide (NASA TM 86143) and includes more detailed information on the solar data calibration, screening procedures, updated solar data plots, and applications to solar variability. Details of the tape format, including source code to access ESAT, are included.

  15. Process of Making Boron-Fiber Reinforced Composite Tape

    NASA Technical Reports Server (NTRS)

    Belvin, Harry L. (Inventor); Cano, Roberto J. (Inventor); Johnston, Norman J. (Inventor); Marchello, Joseph M. (Inventor)

    2002-01-01

    The invention is an apparatus and method for producing a hybrid boron reinforced polymer matrix composition from powder pre-impregnated fiber tow bundles and a linear array of boron fibers. The boron fibers are applied onto the powder pre-impregnated fiber tow bundles and then are processed within a processing component having an impregnation bar assembly. After passing through variable-dimension forming nip-rollers, the powder pre-impregnated fiber tow bundles with the boron fibers become a hybrid boron reinforced polymer matrix composite tape. A driving mechanism pulls the powder pre-impregnated fiber tow bundles with boron fibers through the processing line of the apparatus and a take-up spool collects the formed hybrid boron-fiber reinforced polymer matrix composite tape.

  16. Kinesiology taping as an adjunct for pain management in cancer?

    PubMed

    Banerjee, Gourav; Rebanks, Jonathan; Briggs, Michelle; Johnson, Mark I

    2016-07-14

    We present the case of a 46-year-old woman who developed severe pain described as 'tearing' and 'searing' in the left side of the mid-trapezius region near the thoracic 8 vertebra (T8). The patient had undergone surgery for T8 fracture which had resulted from metastasis (secondary breast cancer). A community nurse referred the patient for physiotherapy assessment and treatment for her musculoskeletal pain and related symptoms that had affected her mobility and functional activities. The patient was treated with soft tissue therapy with the addition of kinesiology taping on follow-up visits. Kinesiology tape was applied over her left side trapezius region and left shoulder. The patient reported significant reductions in pain severity and felt greater control and stability over her left shoulder region, which resulted in better function and overall quality of life measures. She did not report any adverse effects.

  17. What would be conserved if "the tape were played twice"?

    PubMed Central

    Fontana, W; Buss, L W

    1994-01-01

    We develop an abstract chemistry, implemented in a lambda-calculus-based modeling platform, and argue that the following features are generic to this particular abstraction of chemistry; hence, they would be expected to reappear if "the tape were run twice": (i) hypercycles of self-reproducing objects arise; (ii) if self-replication is inhibited, self-maintaining organizations arise; and (iii) self-maintaining organizations, once established, can combine into higher-order self-maintaining organizations. PMID:8290596

  18. STS 110 Mission Highlights Resource Tape. Part 4 of 4

    NASA Technical Reports Server (NTRS)

    2002-01-01

    A continuation of 'STS 110 Mission Highlights Resource Tape'. This video, Part 4 of 4, shows footage from flight days 10 through 12 of STS-110. The spacecrew includes Michael J. Bloomfield, Commander; Stephen N. Frick, Pilot; Jerry L. Ross, Mission Specialist; Steven L. Smith, Mission Specialist; Ellen Ochoa, Mission Specialist; Lee M.E. Morin, Mission Specialist; Rex J. Walheim, Mission Specialist. Flight day 10 includes an exchange of farewells with the Expedition 4 crew (Yury I. Onufrienko, Commander; Daniel W. Bursch, Flight Engineer; Carl E. Walz, Flight Engineer) of the International Space Station (ISS), and undocking. The video includes many views of the ISS as Atlantis departs, including cloud cover and the Earth's limb as backgrounds. There is also a view of Atlantis with its payload bay open. On flight day 11, in preparation for landing, the crew conducts a checkout of flight controls and a test firing. A spaceborne wheat plant experiment onboard the ISS is briefly shown. Flight day 12 includes closing the payload bay, suit-up, and landing. Kennedy Space Center is seen from the air, and the video shows landing replays, as well as a heads-up display view of the landing. Earth views include clear views of Western Sahara, Morocco, Mauritania, and Algeria, with the Atlantic Ocean, a cloud obstructed view of Newfoundland and the Atlantic, Pacific Ocean sun glint, and an excellent view of the Chicago area and Lake Michigan at night. The activities from other flights days can be seen on "STS 110 Mission Highlights Resource Tape" Part 1 of 4 (internal ID 2002137575), "STS 110 Mission Highlights Resource Tape" Part 2 of 4 (internal ID 2002137573), and "STS 110 Mission Highlights Resource Tape" Part 3 of 4 (internal ID 2002137574).

  19. STS 110 Mission Highlights Resource Tape. Part 3 of 4

    NASA Technical Reports Server (NTRS)

    2002-01-01

    A continuation of 'STS 110 Mission Highlights Resource Tape'. This video, Part 3 of 4, shows footage from flight days 6 through 9 of STS-110. The spacecrew includes Michael J. Bloomfield, Commander Stephen N. Frick, Pilot; Jerry L. Ross, Mission Specialist; Steven L. Smith, Mission Specialist; Ellen Ochoa, Mission Specialist; Lee M.E. Morin, Mission Specialist; Rex J. Walheim, Mission Specialist. On flight day 6, Ross and Morin conduct an EVA (extravehicular activity) to secure a tripod like strut to the S0 Truss of the International Space Station (ISS). They also move the drag link and keel pins from one face of the Truss to the other to free the rail on the truss for a railcar to move. Smith installs a camera onto the CANADARM robotic arm on flight day 7, and on flight day 8 the restraints are removed from the railcar connected to the S0 Truss in preparation for checkout. The checkout of the railcar is shown, including its inaugural run. Ross and Morin conduct another EVA on flight day 9 to complete the outfitting of the S0 Truss Structure. Notable footage includes views of Ross and Morin at work from the helmet-mounted camera on Ross' EVA suit, including close-ups of the pistol grip tool, CANADARM 2 onboard the ISS lit at sunrise, a 'diamond ring' effect formed by the Sun between the Earth's limb and the ISS, a brief shot of the Yucatan peninsula, and a end-to-end pan down the length of the ISS. The activities from other flights days can be seen on "STS 110 Mission Highlights Resource Tape" Part 1 of 4 (internal ID 2002137575), "STS 110 Mission Highlights Resource Tape" Part 2 of 4 (internal ID 2002137573), and "STS 110 Mission Highlights Resource Tape" Part 4 of 4 (internal ID 2002137517).

  20. IMP F and G phase 1 magnetic field analysis

    NASA Technical Reports Server (NTRS)

    Mish, W. H.

    1972-01-01

    The program developed to analyze magnetic field data from the magnetic field experiment flown in IMP F is reported. The analysis converts the raw X, Y, Z sensor data as received on the magnetic field experiment tape into vector measurements of the ambient magnetic field observed by the experiment. These data are computed for four frames of reference -- apparent, payload, solar ecliptic and solar magnetospheric. In addition 20.45 second statistics are computed for the last three coordinate systems. Finally, a summary tape is produced containing detailed data and sequence statistics as well as the output from the autocorrelation computer, trajectory data and identification information.

  1. Visualization of Flows in Packed Beds of Twisted Tapes

    NASA Technical Reports Server (NTRS)

    Hendricks, R. C.; Braun, M. J.; Peloso, D.; Athavale, M. M.; Mullen, R. L.

    2002-01-01

    A videotape presentation of the flow field in a packed bed of 48 twisted tapes which can be simulated by very thin virtual cylinders has been assembled. The indices of refraction of the oil and the Lucite twisted tapes were closely matched, and the flow was seeded with magnesium oxide particles. Planar laser light projected the flow field in two dimensions both along and transverse to the flow axis. The flow field was three dimensional and complex to describe, yet the most prominent finding was flow threads. It appeared that axial flow spiraled along either within the confines of a virtual cylindrical boundary or within the exterior region, between the tangency points, of the virtual cylinders. Random packing and bed voids created vortices and disrupted the laminar flow but minimized the entrance effects. The flow-pressure drops in the packed bed fell below the Ergun model for porous-media flows. Single-twisted-tape results of Smithberg and Landis (1964) were used to guide the analysis. In appendix A the results of several investigators are scaled to the Ergun model. Further investigations including different geometric configurations, computational fluid dynamic (CFD) gridding, and analysis are required.

  2. The Accuracy of Broselow Tape Weight Estimate among Pediatric Population

    PubMed Central

    AlGarni, Abdullaziz; AlGamdi, Fasial; Jawish, Mona; Wani, Tariq Ahmad

    2016-01-01

    Objective. To determine the accuracy of the Broselow Tape (BT) versions 2007 and 2011 in estimating weight among pediatric population. Methods. A cross-sectional study was conducted at King Fahad Medical City and six schools across Riyadh province on 1–143-month-old children. BT 2007 and 2011 estimated weights were recorded. Both tapes via the child's height produce an estimated weight, which was compared with the actual weight. Results. A total of 3537 children were recruited. The height (cm) of the subjects was 97.7 ± 24.1 and the actual weight (kg) was 16.07 ± 8.9, whereas the estimated weight determined by BT 2007 was 15.87 ± 7.56 and by BT 2011 was 16.38 ± 7.95. Across all the five age groups, correlation between actual weight and BT 2007 ranged between 0.702 and 0.788, while correlation between actual weight and BT 2011 ranged between 0.698 and 0.788. Correlation between BT 2007 and BT 2011 across all the five age groups ranged from 0.979 to 0.989. Accuracy of both the tape versions was adversely affected when age was >95 months and body weight was >26 kilograms. Conclusions. Our study showed that BT 2007 and 2011 provided accurate estimation of the body weight based on measured body height. However, 2011 version provided more precise estimate for weight. PMID:27668258

  3. Flow Visualizations in a Packed Bed of Twisted Tapes

    NASA Technical Reports Server (NTRS)

    Hendricks, R. C.; Braun, M. J.

    2002-01-01

    A videotape presentation of the flow field in a packed bed of 48 twisted tapes which can be simulated by very thin virtual cylinders has been assembled. The indices of refraction of the oil and the Lucite twisted tapes were closely matched, and the flow was seeded with magnesium oxide particles. Planar laser light projected the flow field in two dimensions both along and transverse to the flow axis. The flow field was three dimensional and complex to describe, yet the most prominent finding was flow threads. It appeared that axial flow spiraled along either within the confines of a virtual cylindrical boundary or within the exterior region, between the tangency points, of the virtual cylinders. Random packing and bed voids created vortices and disrupted the laminar flow but minimized the entrance effects. The flow-pressure drops in the packed bed fell below the Ergun model for porous-media flows. Single-twisted-tape results of Smithberg and Landis (1964) were used to guide the analysis. In appendix A the results of several investigators are scaled to the Ergun model. Further investigations including different geometric configurations, computational fluid dynamic (CFD) gridding, and analysis are required.

  4. The Accuracy of Broselow Tape Weight Estimate among Pediatric Population

    PubMed Central

    AlGarni, Abdullaziz; AlGamdi, Fasial; Jawish, Mona; Wani, Tariq Ahmad

    2016-01-01

    Objective. To determine the accuracy of the Broselow Tape (BT) versions 2007 and 2011 in estimating weight among pediatric population. Methods. A cross-sectional study was conducted at King Fahad Medical City and six schools across Riyadh province on 1–143-month-old children. BT 2007 and 2011 estimated weights were recorded. Both tapes via the child's height produce an estimated weight, which was compared with the actual weight. Results. A total of 3537 children were recruited. The height (cm) of the subjects was 97.7 ± 24.1 and the actual weight (kg) was 16.07 ± 8.9, whereas the estimated weight determined by BT 2007 was 15.87 ± 7.56 and by BT 2011 was 16.38 ± 7.95. Across all the five age groups, correlation between actual weight and BT 2007 ranged between 0.702 and 0.788, while correlation between actual weight and BT 2011 ranged between 0.698 and 0.788. Correlation between BT 2007 and BT 2011 across all the five age groups ranged from 0.979 to 0.989. Accuracy of both the tape versions was adversely affected when age was >95 months and body weight was >26 kilograms. Conclusions. Our study showed that BT 2007 and 2011 provided accurate estimation of the body weight based on measured body height. However, 2011 version provided more precise estimate for weight.

  5. STS 110 Mission Highlights Resource Tape. Part 1 of 4

    NASA Technical Reports Server (NTRS)

    2002-01-01

    This video, Part 1 of 4, shows footage from flight days 1 and 2, and part of day 3, of STS-110. The spacecrew includes Michael J. Bloomfield, Commander; Stephen N. Frick, Pilot; Jerry L. Ross, Mission Specialist; Steven L. Smith, Mission Specialist; Ellen Ochoa, Mission Specialist; Lee M.E. Morin, Mission Specialist; Rex J. Walheim, Mission Specialist. They are shown at their pre-launch meal, introducing themselves and talking about their roles on the coming flight. The launch of Atlantis is shown, with replays. On flight day 2, the crew conducts a checkout of the CANADARM robotic arm. Flight day 3 includes Atlantis docking with the International Space Station (ISS), firing its thrusters to reach it. The approach and docking are shown. Other notable footage includes CANADARM with the Earth's limb in the background, Atlantis moving over a cloud cover background, sunlight from behind the Earth's limb, showing the "diamond ring" effect, sunrise upon Atlantis, and the docking hatches of the two spacecraft during approach. The activities from other flights days can be seen on "STS 110 Mission Highlights Resource Tape" Part 2 of 4 (internal ID 2002137573), "STS 110 Mission Highlights Resource Tape" Part 3 of 4 (internal ID 2002137574), and "STS 110 Mission Highlights Resource Tape" Part 4 of 4 (internal ID 2002137517).

  6. Digital Linear Tape (DLT) technology and product family overview

    NASA Technical Reports Server (NTRS)

    Lignos, Demetrios

    1994-01-01

    The demand that began a couple of years ago for increased data storage capacity continues. Peripheral Strategies (a Santa Barbara, California, Storage Market Research Firm) projects the amount of data stored on the average enterprise network will grow by 50 percent to 100 percent per year. Furthermore, Peripheral Strategies says that a typical mid-range workstation system containing 30GB to 50GB of storage today will grow at the rate of 50 percent per year. Dan Friedlander, a Boulder, Colorado-based consultant specializing in PC-LAN backup, says, 'The average NetWare LAN is about 8GB, but there are many that have 30GB to 300GB.....' The substantial growth of storage requirements has created various tape technologies that seek to satisfy the needs of today's and, especially, the next generations's systems and applications. There are five leading tape technologies in the market today: QIC (Quarter Inch Cartridge), IBM 3480/90, 8mm, DAT (Digital Audio Tape) and DLT (Digital Linear Tape). Product performance specifications and user needs have combined to classify these technologies into low-end, mid-range, and high-end systems applications. Although the manufacturers may try to position their products differently, product specifications and market requirements have determined that QIC and DAT are primarily low-end systems products while 8mm and DLT are competing for mid-range systems applications and the high-end systems space, where IBM compatibility is not required. The 3480/90 products seem to be used primarily in the IBM market, for interchangeability purposes. There are advantages and disadvantages for each of the tape technologies in the market today. We believe that DLT technology offers a significant number of very important features and specifications that make it extremely attractive for most current as well as emerging new applications, such as Hierarchical Storage Management (HSM). This paper will demonstrate why we think that the DLT technology and family

  7. Test results of HTS magnet for SMES application

    NASA Astrophysics Data System (ADS)

    Kozak, J.; Majka, M.; Jaroszynski, L.; Janowski, T.; Kozak, S.; Kondratowicz – Kucewicz, B.; Wojtasiewicz, G.

    2010-06-01

    The magnet for a superconducting magnetic energy storage system (SMES) conducting cooled by SRDK-408 cryocooler is described in this paper. The superconducting magnet consists of 7 double-pancake coils made of Bi-2223 HTS tape with the inner and outer diameters 210 mm, 315 mm respectively and height of 191 mm. The inductance of the magnet is approximately 1 H. In this paper we report the design improvements and the measurement results taken at the cooling of the magnet.

  8. The application of isotope ratio mass spectrometry for discrimination and comparison of adhesive tapes.

    PubMed

    Horacek, Micha; Min, Ji-Sook; Heo, Sangcheol; Park, Jongseo; Papesch, Wolfgang

    2008-06-01

    Forensic scientists are frequently requested to differentiate between, or compare, adhesive tapes from a suspect or a crime scene. The most common polymers used to back packaging tape are polypropylene and polyvinyl chloride. Much of the oriented polypropylene (OPP) needed to produce packaging tapes, regardless of the tape brand, is supplied by just a few polymer manufacturers. Consequently, the composition of the backing material varies little. Therefore, the discriminating power of classical methods (physical fit, tape dimensions, colour, morphology, FTIR, PyGC/MS, etc.) is limited. Analysis of stable isotopes using isotope ratio mass spectrometry (IRMS) has been applied in the broad area of forensics and it has been reported that isotope analysis is a valuable tool for the identification of adhesive tapes. We have tested the usefulness of this method by distinguishing different South Korean adhesive tapes produced by just a few manufacturers in the small South Korean market. Korean adhesive tapes were collected and analysed for their isotope signatures. The glue of the tapes was separated from the backing material and these sub-samples were analysed for their H- and C-isotope composition. The result shows the possibility for discriminating most tape samples, even from the same brand. Variations within single rolls have also been investigated, where no variations in H- and C-isotope composition significantly exceeding the standard deviation were found. PMID:18438979

  9. The application of isotope ratio mass spectrometry for discrimination and comparison of adhesive tapes.

    PubMed

    Horacek, Micha; Min, Ji-Sook; Heo, Sangcheol; Park, Jongseo; Papesch, Wolfgang

    2008-06-01

    Forensic scientists are frequently requested to differentiate between, or compare, adhesive tapes from a suspect or a crime scene. The most common polymers used to back packaging tape are polypropylene and polyvinyl chloride. Much of the oriented polypropylene (OPP) needed to produce packaging tapes, regardless of the tape brand, is supplied by just a few polymer manufacturers. Consequently, the composition of the backing material varies little. Therefore, the discriminating power of classical methods (physical fit, tape dimensions, colour, morphology, FTIR, PyGC/MS, etc.) is limited. Analysis of stable isotopes using isotope ratio mass spectrometry (IRMS) has been applied in the broad area of forensics and it has been reported that isotope analysis is a valuable tool for the identification of adhesive tapes. We have tested the usefulness of this method by distinguishing different South Korean adhesive tapes produced by just a few manufacturers in the small South Korean market. Korean adhesive tapes were collected and analysed for their isotope signatures. The glue of the tapes was separated from the backing material and these sub-samples were analysed for their H- and C-isotope composition. The result shows the possibility for discriminating most tape samples, even from the same brand. Variations within single rolls have also been investigated, where no variations in H- and C-isotope composition significantly exceeding the standard deviation were found.

  10. Method and apparatus for depositing a coating on a tape carrier

    DOEpatents

    Storer, Jonathan; Matias, Vladimir

    2010-06-15

    A system and method for depositing ceramic materials, such as nitrides and oxides, including high temperature superconducting oxides on a tape substrate. The system includes a tape support assembly that comprises a rotatable drum. The rotatable drum supports at least one tape substrate axially disposed on the surface of the drum during the deposition of metals on the tape and subsequent oxidation to form the ceramic materials. The drum is located within a stator having a slot that is axially aligned with the drum. A space exists between the drum and stator. The space is filled with a predetermined partial pressure of a reactive gas. The drum, stator, and space are heated to a predetermined temperature. To form the ceramic material on the tape substrate, the drum is first rotated to align the tape substrate with the slot, and at least one metal is deposited on the substrate. The drum then continues to rotate, bringing the tape substrate into the space, where the metal deposited on the tape substrate reacts with the reactive gas to form the ceramic material. In one embodiment, the tape support system also includes a pay-out/take-up system that co-rotates with the drum and provides a continuous length of tape substrate.

  11. EFFECT OF ATHLETIC TAPING AND KINESIOTAPING® ON MEASUREMENTS OF FUNCTIONAL PERFORMANCE IN BASKETBALL PLAYERS WITH CHRONIC INVERSION ANKLE SPRAINS

    PubMed Central

    Karatas, Nihan; Baltaci, Gul

    2012-01-01

    Background: Chronic inversion ankle sprains are common in basketball players. The effect of taping on functional performance is disputed in the literature. Kinesiotaping® (KT®) is a new method that is being used as both a therapeutic and performance enhancement tool. To date, it appears that no study has investigated the effect of ankle KT® on functional performance. Purpose: To investigate the effects of different types of taping (KT® using Kinesio Tex®, athletic taping) on functional performance in athletes with chronic inversion sprains of the ankle. Study Design: Crossover Study Design Methods: Fifteen male basketball players with chronic inversion ankle sprains between the ages of 18 and 22 participated in this study. Functional performance tests (Hopping test by Amanda et al, Single Limb Hurdle Test, Standing Heel Rise test, Vertical Jump Test, The Star Excursion Balance Test [SEBT] and Kinesthetic Ability Trainer [KAT] Test) were used to quantify agility, endurance, balance, and coordination. These tests were conducted four times at one week intervals using varied conditions: placebo tape, without tape, standard athletic tape, and KT®. One-way ANOVA tests were used to examine difference in measurements between conditions. Bonferroni correction was applied to correct for repeated testing. Results: There were no significant differences among the results obtained using the four conditions for SEBT (anterior p=0.0699; anteromedial p=0.126; medial p=0.550; posteromedial p=0.587; posterior p=0.754; posterolateral p=0.907; lateral p=0.124; anterolateral p=0.963) and the KAT dynamic measurement (p=0.388). Faster performance times were measured with KT® and athletic tape in single limb hurdle test when compared to placebo and non-taped conditions (Athletic taping- placebo taping: p=0.03; athletic taping- non tape p=0.016;KT®- Placebo taping p=0.042; KT®-Non tape p=0.016). In standing heel rise test and vertical jump test, athletic taping led to decreased

  12. Adhesion in ceramics and magnetic media

    NASA Technical Reports Server (NTRS)

    Miyoshi, Kazuhisa

    1989-01-01

    When a ceramic is brought into contact with a metal or a polymeric material such as a magnetic medium, strong bonds form between the materials. For ceramic-to-metal contacts, adhesion and friction are strongly dependent on the ductility of the metals. Hardness of metals plays a much more important role in adhesion and friction than does the surface energy of metals. Adhesion, friction, surface energy, and hardness of a metal are all related to its Young's modulus and shear modulus, which have a marked dependence on the electron configuration of the metal. An increase in shear modulus results in a decrease in area of contact that is greater than the corresponding increase in surface energy (the fond energy) with shear modulus. Consequently, the adhesion and friction decrease with increasing shear modulus. For ceramics in contact with polymeric magnetic tapes, environment is extremely important. For example, a nitrogen environment reduces adhesion and friction when ferrite contacts polymeric tape, whereas a vacuum environment strengthens the ferrite-to-tape adhesion and increases friction. Adhesion and friction are strongly dependent on the particle loading of the tape. An increase in magnetic particle concentration increases the complex modulus of the tape, and a lower real area of contact and lower friction result.

  13. THE RELIABILITY OF THE MODIFIED REVERSE-6 TAPING PROCEDURE WITH ELASTIC TAPE TO ALTER THE HEIGHT AND WIDTH OF THE MEDIAL LONGITUDINAL ARCH

    PubMed Central

    Lebec, Michael; DeGeyter, Julie; McPoil, Thomas G.

    2013-01-01

    Purpose/Background: Anti-pronation-taping utilizing both inelastic and elastic tape has been advocated to reduce pain and symptoms associated with excessive foot pronation. An important question regarding the use of taping is whether it can be applied consistently from one therapist to the next, from one session to the next or from one day to the next. Thus, the purpose of this study was to determine whether the “modified” Reverse-6 taping procedure using elastic tape could be applied to produce a consistent within-day and between-day change in the height and width of the medial longitudinal arch for a single clinician as well as between clinicians. A second purpose was to determine if the amount of general clinical experience influenced this consistency. Methods: Fifteen asymptomatic individuals (10 female and 5 male) with a mean age of 28.7 years were recruited to participate in this study. The height and width of the midfoot at 50% of each subject's foot length was measured in standing using a digital gauge and caliper. These measurements were done twice on the same day, on two different days and again by two clinicians with different levels of experience before and after having their feet taped using the “modified” Reverse-6 taping technique using elastic tape. Both clinicians received a one-hour training session on how to apply the taping technique and were also given a DVD showing the technique that they could review. In addition to descriptive statistics, intra-class correlation coefficients (ICC) were used to assess each clinician's within-day and between-day reliability. Between-clinician reliability was also determined. Results: The mean dorsal arch height and midfoot width before the application of tape was 62.7 and 78.9 mm. The mean dorsal arch height and width after the application of tape was 66.6 and 78.8 mm. The within-day reliability ICC(2,1) values for the two clinicians ranged from .865 to .991. The between-day reliability ICC(2,1) values

  14. Quasi-continuous magnets

    SciTech Connect

    Sims, J.R.; Naumovich, G.J.; Hoang, T.A.; Dent, P.C.

    1996-05-01

    The National High Magnetic Field Laboratory is completing a quasi-continuous magnet which will sustain a constant field of 60 T for 100 ms in a 32-mm 77 K bore. This magnet consists of 9 mechanically independent, nested, liquid nitrogen-cooled coils which are individually reinforced by high-strength stainless steel outer shells. The coils were wound from rectangular large cross-section, high-strength, high-conductivity copper conductor insulated wtih polyimide and fiberglass tapes. After winding, the coils were inserted into closely fitted, stainless steel reinforcing shells and impregnated with epoxy resin. Design, analysis, material, fabrication and operational issues for this class of magnets are reviewed. Fabrication and quality assurance testing of the 60 T coil set are covered in detail. Future growth of and possible links from this technology to other magnet systems are discussed. Needed improvements in design, analysis, materials, and fabrication are outlined.

  15. Influence of walking with talus taping on the ankle dorsiflexion passive range of motion.

    PubMed

    Kang, Min-Hyeok; Kim, Ji-Won; Kim, Moon-Hwan; Park, Tae-Jin; Park, Ji-Hyuk; Oh, Jae-Seop

    2013-08-01

    [Purpose] This study investigated the effects of walking with talus taping on the ankle dorsiflexion passive range of motion (DF PROM) in individuals with limited ankle DF PROM. [Subjects] Fifteen ankles with limited DF PROM were examined. [Methods] After rigid strapping tape was applied to the ankles from the talus to the calcaneus, progressing posteriorly and inferiorly, the subjects walked on a walkway for 10 min. Using a goniometer, the ankle DF PROM was measured with the knee extended before and after walking with talus taping. The difference in ankle DF PROM between before and after walking with talus taping was analyzed using the paired t-test. [Results] The ankle DF PROM was significantly increased after walking with talus taping. [Conclusion] Our findings indicate that walking with talus taping is effective for increasing the ankle DF PROM in individuals with limited ankle DF PROM. PMID:24259905

  16. Influence of Walking with Talus Taping on the Ankle Dorsiflexion Passive Range of Motion

    PubMed Central

    Kang, Min-Hyeok; Kim, Ji-Won; Kim, Moon-Hwan; Park, Tae-Jin; Park, Ji-Hyuk; Oh, Jae-Seop

    2013-01-01

    [Purpose] This study investigated the effects of walking with talus taping on the ankle dorsiflexion passive range of motion (DF PROM) in individuals with limited ankle DF PROM. [Subjects] Fifteen ankles with limited DF PROM were examined. [Methods] After rigid strapping tape was applied to the ankles from the talus to the calcaneus, progressing posteriorly and inferiorly, the subjects walked on a walkway for 10 min. Using a goniometer, the ankle DF PROM was measured with the knee extended before and after walking with talus taping. The difference in ankle DF PROM between before and after walking with talus taping was analyzed using the paired t-test. [Results] The ankle DF PROM was significantly increased after walking with talus taping. [Conclusion] Our findings indicate that walking with talus taping is effective for increasing the ankle DF PROM in individuals with limited ankle DF PROM. PMID:24259905

  17. Dry Process for Making Polyimide/ Carbon-and-Boron-Fiber Tape

    NASA Technical Reports Server (NTRS)

    Belvin, Harry L.; Cano, Roberto J.; Johnston, Norman J.; Marchello, Joseph M.

    2003-01-01

    A dry process has been invented as an improved means of manufacturing composite prepreg tapes that consist of high-temperature thermoplastic polyimide resin matrices reinforced with carbon and boron fibers. Such tapes are used (especially in the aircraft industry) to fabricate strong, lightweight composite-material structural components. The inclusion of boron fibers results in compression strengths greater than can be achieved by use of carbon fibers alone. The present dry process is intended to enable the manufacture of prepreg tapes (1) that contain little or no solvent; (2) that have the desired dimensions, fiber areal weight, and resin content; and (3) in which all of the fibers are adequately wetted by resin and the boron fibers are fully encapsulated and evenly dispersed. Prepreg tapes must have these properties to be useable in the manufacture of high-quality composites by automated tape placement. The elimination of solvent and the use of automated tape placement would reduce the overall costs of manufacturing.

  18. Effects of Kinesio taping on joint position sense of the ankle

    PubMed Central

    Seo, Hyun-Do; Kim, Min-Young; Choi, Jung-Eun; Lim, Ga-Hee; Jung, Seong-In; Park, So-Hyun; Cheon, Song-Hee; Lee, Hae-Yong

    2016-01-01

    [Purpose] The purpose of this study was to examine the effect of Kinesio taping on the joint position sense of the ankle. [Subjects and Methods] The subjects of this study were 26 nomal adults who had experienced ankle sprain. Kinesio taping was applied over the ankle medial ligament and ankle lateral ligament with eight pattern reinforcement taping. Joint position sense was measured using isokinetic equipment (Biodex System 4 pro dynamometer, Biodex Medical systems Inc., USA) during dorsiflexion/plantarflexion and inversion/eversion, before and after taping. Statistical analyses were performed using SPSS 21.0 for Windows. [Results] Joint position sense after Kinesio taping was improved in the dorsiflexion and inversion positions. [Conclusion] According to the results of this study, Kinesio taping of the ankle is effective for the prevention of ankle sprain. PMID:27190446

  19. Effects of Lower-Leg Kinesiology Taping on Balance Ability in Stroke Patients with Foot Drop

    PubMed Central

    Bae, Young-Hyeon; Kim, Hyeong Geun; Min, Kyung Sam; Lee, Suk Min

    2015-01-01

    Objective. The purpose of this study was to observe the effects of lower-leg kinesiology taping on balance ability in stroke patients with foot drop. Design. Randomized controlled trial study. Method. Thirty stroke patients with foot drop were randomly divided into two groups. The experimental group underwent kinesiology taping, and the control group underwent placebo taping. Balance ability was assessed before and after taping in both groups. Results. No difference was observed over time in the Berg Balance Scale score between the two groups, and a significant difference in the Berg Balance Scale score was observed only in the experimental group. Additionally, there were significant differences in the center of pressure area and limits of stability over time. Conclusion. Kinesiology taping temporarily improved static balance ability in stroke patients. However, its effect on dynamic balance was not verified. Therefore, further research on the influence of long-term kinesiology taping on dynamic balance and gait ability is suggested. PMID:26579200

  20. Effects of Lower-Leg Kinesiology Taping on Balance Ability in Stroke Patients with Foot Drop.

    PubMed

    Bae, Young-Hyeon; Kim, Hyeong Geun; Min, Kyung Sam; Lee, Suk Min

    2015-01-01

    Objective. The purpose of this study was to observe the effects of lower-leg kinesiology taping on balance ability in stroke patients with foot drop. Design. Randomized controlled trial study. Method. Thirty stroke patients with foot drop were randomly divided into two groups. The experimental group underwent kinesiology taping, and the control group underwent placebo taping. Balance ability was assessed before and after taping in both groups. Results. No difference was observed over time in the Berg Balance Scale score between the two groups, and a significant difference in the Berg Balance Scale score was observed only in the experimental group. Additionally, there were significant differences in the center of pressure area and limits of stability over time. Conclusion. Kinesiology taping temporarily improved static balance ability in stroke patients. However, its effect on dynamic balance was not verified. Therefore, further research on the influence of long-term kinesiology taping on dynamic balance and gait ability is suggested.

  1. NASA Global Atmospheric Sampling Program (GASP) data report for tape VL0003

    NASA Technical Reports Server (NTRS)

    Holdeman, J. D.

    1976-01-01

    Atmospheric ozone, and related flight and meteorological data for May 1975, obtained during 49 flights of a Pan American World Airways 747, are available as GASP tape VL0003 from the National Climatic Center, Asheville, North Carolina. In addition to the GASP data, tropopause pressure fields obtained from NMC archives for the dates of the GASP flights are included on the data tape. Flight routes and dates, instrumentation, data processing procedures, and data tape specifications are described.

  2. Comanche Helmet-Mounted Display Heading-Tape Simulation

    NASA Technical Reports Server (NTRS)

    Turpin, Terry; Dowell, Susan; Atencio, Adolph

    2006-01-01

    The Aeroflightdynamics Directorate (AMRDEC) conducted a simulation to assess the performance associated with a Contact Analog, world-referenced heading tape as implemented on the Comanche Helmet Integrated Display Sight System (HIDSS) when compared with a Compressed heading tape similar to that specified by the former Military Standard (MIL-STD) 1295. Six experienced pilots flew three modified Aeronautical Design Standards (ADS)-33 maneuvers (Hover Turn, Bob-up, Transient Turn) and a precision traffic pattern in the NASA Vertical Motion Simulator (VMS). Analysis of the pilot objective performance data and subjective handling qualities ratings (HQRs) showed the following: Compressed symbology in the Velocity Stabilization (VelStab) flight mode generally produced the most precise performances over Contact Analog symbology with respect to the heading, altitude, position, and time criteria specified for the maneuvers tested. VelStab outperformed the Automatic Flight Control System (AFCS) on all maneuvers achieving desired performance on most maneuvers for both symbol sets. Performance in the AFCS mode was generally desirable to adequate for heading and altitude and did not meet adequate standards for hover position and time for the Hover Turn and Bob-up maneuvers. VelStab and AFCS performance were nearly the same for the Transient Turn. Pilot comments concerning the Contact Analog heading-tape implementation were generally unfavorable in spite of the achieved levels of performance. HQRs showed Compressed symbology in the VelStab flight mode produced the lowest mean HQR, encompassing mixed ratings of satisfactory handling and needing improvement. All other symbology/flight-mode combinations yielded higher HQRs, which characterized opinions that deficiencies in aircraft handling due to HMD symbology would need improvement. Contact Analog heading tape and other symbology require improvement, especially when operating in the AFCS mode. NASA-TLX rated Compressed symbology

  3. Thermally Conductive Tape Based on Carbon Nanotube Arrays

    NASA Technical Reports Server (NTRS)

    Kashani, Ali

    2011-01-01

    To increase contact conductance between two mating surfaces, a conductive tape has been developed by growing dense arrays of carbon nanotubes (CNTs, graphite layers folded into cylinders) on both sides of a thermally conductive metallic foil. When the two mating surfaces are brought into contact with the conductive tape in between, the CNT arrays will adhere to the mating surface. The van der Waals force between the contacting tubes and the mating surface provides adhesion between the two mating surfaces. Even though the thermal contact conductance of a single tube-to-tube contact is small, the tremendous amount of CNTs on the surface leads to a very large overall contact conductance. Interface contact thermal resistance rises from the microroughness and the macroscopic non-planar quality of mating surfaces. When two surfaces come into contact with each other, the actual contact area may be much less than the total area of the surfaces. The real area of contact depends on the load, the surface roughness, and the elastic and inelastic properties of the surface. This issue is even more important at cryogenic temperatures, where materials become hard and brittle and vacuum is used, which prevents any gas conduction through the interstitial region. A typical approach to increase thermal contact conductance is to use thermally conducting epoxies or greases, which are not always compatible with vacuum conditions. In addition, the thermal conductivities of these compounds are often relatively low. The CNTs used in this approach can be metallic or semiconducting, depending on the folding angle and diameter. The electrical resistivity of multiwalled carbon nanotubes (MWCNTs) has been reported. MWCNTs can pass a current density and remain stable at high temperatures in air. The thermal conductivity of a MWCNT at room temperature is measured to be approximately 3,000 W/m-K, which is much larger than that of diamond. At room temperature, the thermal conductance of a 0.3 sq cm

  4. Methods for tape fabrication of continuous filament composite parts and articles of manufacture thereof

    DOEpatents

    Weisberg, Andrew H

    2013-10-01

    A method for forming a composite structure according to one embodiment includes forming a first ply; and forming a second ply above the first ply. Forming each ply comprises: applying a bonding material to a tape, the tape comprising a fiber and a matrix, wherein the bonding material has a curing time of less than about 1 second; and adding the tape to a substrate for forming adjacent tape winds having about a constant distance therebetween. Additional systems, methods and articles of manufacture are also presented.

  5. Method for braze-joining spirally wound tapes to inner walls of heat exchanger tubes

    DOEpatents

    Garrison, Melton E.

    1984-01-01

    The present invention is directed to a method of fabricating heat exchanger tubes in which twisted tapes are utilized for promoting turbulence and heat transfer. The method of the present invention provides for the brazing of the tapes to the inner walls of the tubes for enhancing heat transfer between the fluid within the conduit and a fluid medium outside of the conduit by conduction through the tape. The braze joint of the present invention is coextensive with the tape over the entire length thereof within the conduit. The practice of the present invention is achieved by placing a filler wire of brazing metal along the tape at a location removed from the side walls and then heating the conduit and tape sufficiently to effect the displacement of the filler metal by wicking to the contact point between the tape and the conduit wall to form a braze joint coextensive with the length of the tape within the conduit. This arrangement provides maximum heat transfer and assures that the tape is in contact with the conduit over the entire common length thereof.

  6. Method for braze-joining spirally wound tapes to inner walls of heat exchanger tubes

    DOEpatents

    Garrison, M.E.

    1982-09-03

    The present invention is directed to a method of fabricating heat exchanger tubes in which twisted tapes are utilized for promoting turbulence and heat transfer. The method of the present invention provides for the brazing of the tapes to the inner walls of the tubes for enhancing heat transfer between the fluid within the conduit and a fluid medium outside of the conduit by conduction through the tape. The braze joint of the present invention is coextensive with the tape over the entire length thereof within the conduit. The practice of the present invention is achieved by placing a filler wire of brazing metal along the tape at a location removed from the side walls and then heating the conduit and tape sufficiently to effect the displacement of the filler metal by wicking to the contact point between the tape and the conduit wall to form a braze joint coextensive with the length of the tape within the conduit. This arrangement provides maximum heat transfer and assures that the tape is in contact with the conduit over the entire common length thereof.

  7. Integration of altitude and airspeed information into a primary flight display via moving-tape formats

    NASA Technical Reports Server (NTRS)

    Abbott, Terence S.; Steinmetz, George G.

    1987-01-01

    A ground-based aircraft simulation study was conducted to determine the effect on pilot performance of replacing the electromechanical altimeter and airspeed indicators with electronically generated representations integrated into the primary flight display via moving-tape (linear moving scale) formats. Several key factors relating to moving-tape formats were examined during the study: tape centering, secondary (trend) information, and tape orientation. The factor of centering refers to whether the tape was centered about the actual airspeed or altitude or about some defined reference value. Tape orientation refers to whether the values represented are arranged in either descending or ascending order. Six pilots participated in this study, with each subject performing 18 runs along a single, known flight profile. Subjective results indicated that the moving-tape formats were generally better than that of the conventional instruments. They also indicated that an actual-centered fixed pointer was preferred to a reference-centered pointer. Performance data for a visual secondary task showed that formats not containing trend information produced better performance; however, no difference was noted in airspeed tracking or altitude tracking performance. Regarding tape orientation, subjective comments indicated that there was lower work load and better performance when the airspeed tape had the high numbers at the top.

  8. The statistical evaluation of duct tape end match as physical evidence

    NASA Astrophysics Data System (ADS)

    Chan, Ka Lok

    Duct tapes are often submitted to crime laboratories as evidence associated with abductions, homicides, or construction of explosive devices. As a result, trace evidence examiners are often asked to analyze and compare commercial duct tapes so that they can establish possible evidentiary links. Duct tape end matches are believed to be the strongest association between exemplar and question samples because they are considered as evidence with unique individual characteristics. While end match analysis and comparison have long been undertaken by trace evidence examiners, there is a significant lack of scientific research for associating two or more segments of duct tapes. This study is designed to obtain statistical inferences on the uniqueness of duct tape tears. Three experiments were devised to compile the basis for a statistical assessment of the probability of duct tape end matches along with a proposed error rate. In one experiment, we conducted the equivalent of 10,000 end match examinations with an error rate of 0%. In the second experiment, we performed 2,704 end match examinations having 0% error rate. In the third experiment, using duct tape by an Elmendorf Tear tester, we conducted 576 end match examinations with an error rate of 0% and having all samples correctly associated. The results of this study indicate that end matches are distinguishable among a single roll of duct tape and between two different rolls of duct tape having very similar surface features and weave pattern.

  9. Rapid prototyping of microfluidic systems using a PDMS/polymer tape composite.

    PubMed

    Kim, Jungkyu; Surapaneni, Rajesh; Gale, Bruce K

    2009-05-01

    Rapid prototyping of microfluidic systems using a combination of double-sided tape and PDMS (polydimethylsiloxane) is introduced. PDMS is typically difficult to bond using adhesive tapes due to its hydrophobic nature and low surface energy. For this reason, PDMS is not compatible with the xurography method, which uses a knife plotter and various adhesive coated polymer tapes. To solve these problems, a PDMS/tape composite was developed and demonstrated in microfluidic applications. The PDMS/tape composite was created by spinning it to make a thin layer of PDMS over double-sided tape. Then the PDMS/tape composite was patterned to create channels using xurography, and bonded to a PDMS slab. After removing the backing paper from the tape, a complete microfluidic system could be created by placing the construct onto nearly any substrate; including glass, plastic or metal-coated glass/silicon substrates. The bond strength was shown to be sufficient for the pressures that occur in typical microfluidic channels used for chemical or biological analysis. This method was demonstrated in three applications: standard microfluidic channels and reactors, a microfluidic system with an integrated membrane, and an electrochemical biosensor. The PDMS/tape composite rapid prototyping technique provides a fast and cost effective fabrication method and can provide easy integration of microfluidic channels with sensors and other components without the need for a cleanroom facility.

  10. Forensic utility of the carbon isotope ratio of PVC tape backings

    NASA Astrophysics Data System (ADS)

    Stern, L. A.; Thompson, A. H.; Mehltretter, A. H.; McLaskey, V.; Parish, A.; Aranda, R.

    2008-12-01

    Forensic interest in adhesive tapes with PVC-backings (polyvinyl chloride, electrical tapes) derives from their use in construction of improvised explosive devices, drug packaging and in a variety of other illicit activities. Due to the range of physical characteristics and chemical compositions of such tapes, traditional microscopic and chemical analysis of the tape backings and adhesives offer a high degree of discrimination between tapes from different manufacturers and products. To evaluate whether carbon isotope ratios may be able to increase discrimination of electrical tapes, particularly with regards to different tapes of the same product, we assessed the PVC-backings of 87 rolls of black electrical tape for their δ13C values. The adhesive on these tapes was physically removed with hexane, and plasticizers within the PVC tape backings were removed by three-20 minute extractions with chloroform. The δ13C values of the PVC tape backings ranged between -23.8 and -41.5 (‰ V-PDB). The carbon isotopic variation within a product (identical brand and product identification) is significant, based on five products with at least 3 rolls (ranges of 7.4‰ (n=3), 10.0‰ (n=6), 4.2‰ (n=16), 3.8‰ (n=6), and 11.5‰ (n=8), respectively). There was no measurable carbon isotope variation in regards to the following: a) along the length of a roll (4 samples from 1 roll); b) between the center and edge of a strip of tape (1 pair); c) between rolls assumed to be from the same lot of tape (2 pairs); d) between different rolls from the same batch of tape (same product purchased at the same time and place; 5 pairs); and e) between samples of a tape at room temperature, heated to 50° C and 80° C for 1 week. For each sample within the population of 87 tapes, carbon isotopes alone exclude 80 to 100% of the tapes as a potential match, with an average exclusion power of 92.5%, using a window of ± 0.4‰. Carbon isotope variations originate from variations in starting

  11. A 5.9 tesla conduction-cooled coil composed of a stack of four single pancakes wound with YBCO wide tapes

    NASA Astrophysics Data System (ADS)

    Iwai, Sadanori; Miyazaki, Hiroshi; Tosaka, Taizo; Tasaki, Kenji; Urata, Masami; Ioka, Shigeru; Ishii, Yusuke

    2013-11-01

    We have been developing a conduction-cooled coil wound with YBCO-coated conductors for HTS applications. Previously, we have fabricated a coil composed of a stack of 12 single pancakes wound with 4 mm-wide YBCO tapes. This coil had a central magnetic field as high as 5.1 T at 10 K under conduction-cooled conditions. In the present study, we fabricated and tested a coil composed of a stack of four single pancakes wound with 12 mm-wide YBCO tapes. The total size of the coil and the Jc value of the tapes were almost the same as those of the former coil. At 77 K, the voltage-current characteristics showed a high n-value of 24, confirming that the coil had no degradation. Furthermore, in a conduction-cooled configuration at 20 K to 60 K, the coil showed a high n-value of over 20. At 20 K, the central magnetic field reached 5.9 T at 903 A, which is 1.3-times higher than that of the former coil.

  12. Technical documentation for the Nonresidential-Buildings Energy-Consumption Survey: 1979-1980, building characteristics, energy end use and fuel oil tank data, public use data tapes. Users' guide

    SciTech Connect

    Not Available

    1982-02-01

    This document provides basic information and technical specifications necessary for using the machine-readable magnetic tapes containing the Building Characteristics, Energy End Use and Fuel Oil Tank data from the 1979-1980 Nonresidential Buildings Energy Consumption Survey (NBECS). Included in this document are a brief overview of the NBECS, technical specifications for reading the tapes and descriptions of the contents of each of the files contained on the tape. The remaining sections are devoted to technical topics of special interest to users of the data. Appended to this document are copies of the questionnaire used in the survey, a listing of the contents of the SPSS labels file, COBOL file description and TPL codebook. The results of the NBECS have been reported in a series of publications which are available to the public. A list of the reports currently available is included here as Appendix H.

  13. Process for preparing tapes from thermoplastic polymers and carbon fibers

    NASA Technical Reports Server (NTRS)

    Chung, Tai-Shung (Inventor); Furst, Howard (Inventor); Gurion, Zev (Inventor); McMahon, Paul E. (Inventor); Orwoll, Richard D. (Inventor); Palangio, Daniel (Inventor)

    1986-01-01

    The instant invention involves a process for use in preparing tapes or rovings, which are formed from a thermoplastic material used to impregnate longitudinally extended bundles of carbon fibers. The process involves the steps of (a) gas spreading a tow of carbon fibers; (b) feeding the spread tow into a crosshead die; (c) impregnating the tow in the die with a thermoplastic polymer; (d) withdrawing the impregnated tow from the die; and (e) gas cooling the impregnated tow with a jet of air. The crosshead die useful in the instant invention includes a horizontally extended, carbon fiber bundle inlet channel, means for providing melted polymer under pressure to the die, means for dividing the polymeric material flowing into the die into an upper flow channel and a lower flow channel disposed above and below the moving carbon fiber bundle, means for applying the thermoplastic material from both the upper and lower channels to the fiber bundle, and means for withdrawing the resulting tape from the die.

  14. Software for Improved Extraction of Data From Tape Storage

    NASA Technical Reports Server (NTRS)

    Cheng, Chiu-Fu

    2002-01-01

    A computer program has been written to replace the original software of Racal Storeplex Delta tape recorders, which are still used at Stennis Space Center but have been discontinued by the manufacturer. Whereas the original software could be activated by a command-line interface only, the present software offers the option of a command-line or graphical user interface. The present software also offers the option of batch-file operation (activation by a file that contains command lines for operations performed consecutively). The present software is also more reliable than was the original software: The original software was plagued by several deficiencies that made it difficult to execute, modify, and test. In addition, when using the original software to extract data that had been recorded within specified intervals of time, the resolution with which one could control starting and stopping times was no finer than about a second (or, in some cases, several seconds). In contrast, the present software is capable of controlling playback times to within 1/100 second of times specified by the user, assuming that the tape-recorder clock is accurate to within 1/100 second.

  15. High solids loading for water-based tape casting

    NASA Astrophysics Data System (ADS)

    Suwannasiri, Thitima

    Tape Casting is a low cost process for making large-area, thin, flat ceramics, which traditionally utilizes organic solvents to allow fast drying.sp{1-4} However, some of the volatile organic compounds (VOC), such as toluene, methylethyl ketone (MEK), and cyclohexanone, are hazardous air pollutants, and their emissions need to be regulated. Therefore, using water as a solvent is desirable to avoid the need of trapping VOCs. Although water is of low cost, nonflammable and safe to the environment, its heat of vaporization is high, 540 kca/g, compared to that of toluene, 74 kca/g.sp7 This makes the drying slow when water is used. The use of water in a tape casting formulation has previously been practical just for applications which require very thin tape, 100-200 mum. A high solids loading of above 50 vol% is an alternative approach to obtain sufficiently rapid drying for a thicker tape (up to 0.8 mm) since the water content is originally minimized. In order to obtain a high solids loading, the dispersants and binder systems were carefully tailored during the present research project. Low molecular weight polyelectrolytes, such as polyacrylic acid PAA (M.W. 1800) and citric acid, were found to be effective for high solids loading of Alsb2Osb3 (A-16SG), for which the electrosteric stabilization played an important role to the stability of the suspension. The viscosity and flow behavior of the suspension strongly depended on pH and the amount of polyelectrolyte, which could be related to the configuration of the polyelectrolyte molecules on the powder surface. The high solids loading of 64.5 vol% could be obtained for the fine A-16SG powder which had a surface area of 9.3 msp2/g. For the coarser powder, A-152SG, the dilatancy was a major problem that obstructed a further rise in solids loading. The dilatancy could be minimized by modifying the size distribution with A-152SG plus A-16SG and using a proper pH and amount of dispersants. An extremely high solids loading of

  16. The Ergogenic Effect of Elastic Therapeutic Tape on Stride and Step Length in Fatigued Runners

    PubMed Central

    Ward, John; Sorrels, Kenneth; Coats, Jesse; Pourmoghaddam, Amir; Moskop, JoAnn; Ueckert, Kate; Glass, Amanda

    2014-01-01

    Objective The purpose of this study was to determine if elastic therapeutic tape placed on anterior lower limbs would affect stride and step length in fatigued runners’ gait. Methods Forty-two healthy participants were equally divided into a kinesiology tape group (Rocktape) and a no-tape control group. Participants in both groups underwent a baseline running gait test at 6 mph without tape. After this, participants engaged in an exhaustive lower body fatigue protocol until they reached maximal volitional exhaustion. Participants were then randomized to 1 of 2 interventions: (1) Experimental group, which had kinesiology tape placed under tension on the anterior aspect of their lower limbs bilaterally from the upper thigh to just below the patella, or (2) Control group, which did not receive taping. All participants then engaged in a similar 6-mph running gait postanalysis. Participant’s gait was analyzed for 90 seconds during each test iteration. Researchers used a 2-way repeated-measures analysis of variance considering fatigue (prefatigue, postfatigue) and group (tape, no-tape) as subject factors. Results After the fatigue protocol, the no-tape group demonstrated a significant decrease in step length of 14.2 mm (P = .041) and stride length of 29.4 mm (P = .043). The kinesiology tape group did not demonstrate a significant decline in these gait parameters. Conclusions In this preliminary study, placing elastic therapeutic tape over the anterior lower limbs demonstrated short-term preservation of runner step length and stride length in a fatigued state. PMID:25435835

  17. 26 CFR 1.6041-7 - Magnetic media requirement.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 26 Internal Revenue 13 2012-04-01 2012-04-01 false Magnetic media requirement. 1.6041-7 Section 1... (CONTINUED) INCOME TAXES (CONTINUED) Information Returns § 1.6041-7 Magnetic media requirement. (a) General... tape or other media, see § 1.9101-1. See also paragraph (b)(2) of § 31.6011(a)-7 of this...

  18. 26 CFR 1.6041-7 - Magnetic media requirement.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 26 Internal Revenue 13 2011-04-01 2011-04-01 false Magnetic media requirement. 1.6041-7 Section 1... (CONTINUED) INCOME TAXES (CONTINUED) Information Returns § 1.6041-7 Magnetic media requirement. (a) General... tape or other media, see § 1.9101-1. See also paragraph (b)(2) of § 31.6011(a)-7 of this...

  19. 26 CFR 1.6041-7 - Magnetic media requirement.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 26 Internal Revenue 13 2013-04-01 2013-04-01 false Magnetic media requirement. 1.6041-7 Section 1... (CONTINUED) INCOME TAXES (CONTINUED) Information Returns § 1.6041-7 Magnetic media requirement. (a) General... tape or other media, see § 1.9101-1. See also paragraph (b)(2) of § 31.6011(a)-7 of this...

  20. 26 CFR 1.6041-7 - Magnetic media requirement.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 26 Internal Revenue 13 2014-04-01 2014-04-01 false Magnetic media requirement. 1.6041-7 Section 1... (CONTINUED) INCOME TAXES (CONTINUED) Information Returns § 1.6041-7 Magnetic media requirement. (a) General... tape or other media, see § 1.9101-1. See also paragraph (b)(2) of § 31.6011(a)-7 of this...

  1. Care and Handling of Computer Magnetic Storage Media.

    ERIC Educational Resources Information Center

    Geller, Sidney B.

    Intended for use by data processing installation managers, operating personnel, and technical staff, this publication provides a comprehensive set of care and handling guidelines for the physical/chemical preservation of computer magnetic storage media--principally computer magnetic tapes--and their stored data. Emphasis is placed on media…

  2. Longevity of duct tape in residential air distribution systems: 1-D, 2-D, and 3-D joints

    SciTech Connect

    Abushakra, Bass

    2002-05-30

    The aging tests conducted so far showed that duct tape tends to degrade in its performance as the joint it is applied to requires a geometrical description of a higher number of space dimensions (1-D, 2-D, 3-D). One-dimensional joints are the easiest to seal with duct tape, and thus the least to experience failure. Two-dimensional joints, such as the flexible duct core-to-collar joints tested in this study, are less likely to fail than three-dimensional collar-to-plenum joints, as the shrinkage could have a positive effect in tightening the joint. Three-dimensional joints are the toughest to seal and the most likely to experience failure. The 2-D flexible duct core-to-collar joints passed the six-month period of the aging test in terms of leakage, but with the exception of the foil-butyl tape, showed degradation in terms hardening, brittleness, partial peeling, shrinkage, wrinkling, delamination of the tape layers, flaking, cracking, bubbling, oozing and discoloration. The baking test results showed that the failure in the duct tape joints could be attributed to the type of combination of the duct tape and the material it is applied to, as the duct tape behaves differently with different substrates. Overall, the foil-butyl tape (Tape 4) had the best results, while the film tape (Tape 3) showed the most deterioration. The conventional duct tapes tested (Tape 1 and Tape 2) were between these two extremes, with Tape 2 performing better than Tape 1. Lastly, we found that plastic straps became discolored and brittle during the tests, and a couple of straps broke completely. Therefore, we recommend that clamping the duct-taped flexible core-to-collar joints should be done with metallic adjustable straps.

  3. Performance measurements and operational characteristics of the Storage Tek ACS 4400 tape library with the Cray Y-MP EL

    NASA Technical Reports Server (NTRS)

    Hull, Gary; Ranade, Sanjay

    1993-01-01

    With over 5000 units sold, the Storage Tek Automated Cartridge System (ACS) 4400 tape library is currently the most popular large automated tape library. Based on 3480/90 tape technology, the library is used as the migration device ('nearline' storage) in high-performance mass storage systems. In its maximum configuration, one ACS 4400 tape library houses sixteen 3480/3490 tape drives and is capable of holding approximately 6000 cartridge tapes. The maximum storage capacity of one library using 3480 tapes is 1.2 TB and the advertised aggregate I/O rate is about 24 MB/s. This paper reports on an extensive set of tests designed to accurately assess the performance capabilities and operational characteristics of one STK ACS 4400 tape library holding approximately 5200 cartridge tapes and configured with eight 3480 tape drives. A Cray Y-MP EL2-256 was configured as its host machine. More than 40,000 tape jobs were run in a variety of conditions to gather data in the areas of channel speed characteristics, robotics motion, time taped mounts, and timed tape reads and writes.

  4. The Effect of Patellar Taping on Squat Depth and the Perception of Pain in People with Anterior Knee Pain

    PubMed Central

    Clifford, Amanda M.; Harrington, Elaine

    Patellar taping is a treatment adjunct commonly used in the management of anterior knee pain. The aim of this cross sectional study was to investigate the effects of medial glide patellar taping on sagittal plane lower-limb joint kinematics and knee pain during a unilateral squat in a symptomatic population complaining of anterior knee pain. Ten participants with a history of unilateral or bilateral anterior knee pain were included in the study. Subjects were required to squat on the symptomatic leg under three conditions: placebo tape, patellar tape and no tape. Kinematic data was recorded using the CODA mpx64 motion analysis system and subjects’ pain was assessed using the Numerical Rating Scale. Patellar taping resulted in a significantly greater single-legged squat depth compared to placebo tape (p=0.008) and no tape (p=0.001) and a statistically significant reduction in pain during a squat compared to placebo tape (p=0.001) or no tape (p=0.001). Significant differences were not identified for maximum knee flexion in the patella taping compared to the no tape condition. This study may have significant clinical implications as participants reported less pain and alterations in sagittal plane movement following the application of patellar tape. PMID:24146711

  5. Fast method for obtaining scale dimensions on tape-controlled milling machine

    NASA Technical Reports Server (NTRS)

    Thompson, L. J.

    1968-01-01

    Calculator obtains the Rail and Z Scale dimensions on the tape-controlled Sundstrand milling machine. It provides computer with depth information required to process numerical control programs which, in turn, provide the tapes for operation of N/C milling machines.

  6. Effects of Tape-Recorded Aural Models on Sight-Reading and Performance Skills.

    ERIC Educational Resources Information Center

    Anderson, James N.

    1981-01-01

    Investigated the effect of using tape-recorded aural models for home practice on selected sight-reading and performance skills of sixth-grade clarinet students. The tape recordings had no observed effects on the selected music skills, nor did the students using them complete more music exercises, as had been hypothesized. (Author/SJL)

  7. Video Tape Feedback in the Development of Listening Skills by Industrial Salesmen.

    ERIC Educational Resources Information Center

    Stroh, Thomas Frederick

    Using role playing and critique methodology, this research study investigated effects on learning caused by self-confrontation via video tape replay compared with audio tape replay. Twenty-five experienced industrial salesmen were taught listening skills, the use of open-ended and reflective questions, and related techniques; and each role played…

  8. The Effect of Mode of Instruction on Learning in a Video Tape Speed Reading System.

    ERIC Educational Resources Information Center

    Bannerman, James W.

    The purpose of this study was to either confirm or refute the claim of the producer of the Time-Life Video Tape Speed Reading system that improved speed would be independent of the time interval between the eight individual taped lessons. The English department at the Southern Technical Institute (Georgia) offered a speed reading course in three…

  9. 75 FR 59752 - Consolidated Tape Association; Notice of Filing and Immediate Effectiveness of the Fifteenth...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-28

    ...; and NYSE Arca, Inc. \\4\\ See Securities Exchange Act Release No. 10787 (May 10, 1974), 39 FR 17799... COMMISSION Consolidated Tape Association; Notice of Filing and Immediate Effectiveness of the Fifteenth Charges Amendment to the Second Restatement of the Consolidated Tape Association Plan September 21,...

  10. TECHNIQUES OF TAPE PREPARATION AND DUPLICATION, WITH SUGGESTIONS FOR A LANGUAGE LABORATORY.

    ERIC Educational Resources Information Center

    Kansas State Dept. of Public Instruction, Topeka.

    PART ONE OF THIS BULLETIN PROVIDES HELP IN THE TWO CRITICAL AREAS OF MASTER TAPE PREPARATION AND DUPLICATION. SUPPLEMENTED BY NUMEROUS PHOTOGRAPHS AND DIAGRAMS OF EQUIPMENT AND DUPLICATION TECHNIQUES, THE BULLETIN DESCRIBES MASTER PROGRAM DUPLICATION USING LANGUAGE LABORATORY EQUIPMENT, A PROFESSIONAL MASS DUPLICATOR, A TAPE RECORDER, A RECORD…

  11. Properties of PTFE tape as a semipermeable membrane in fluorous reactions

    PubMed Central

    Parsons, Brendon A; Smith, Olivia Lin; Chae, Myeong

    2015-01-01

    Summary In a PTFE tape phase-vanishing reaction (PV-PTFE), a delivery tube sealed with PTFE tape is inserted into a vessel which contains the substrate. The reagent diffuses across the PTFE tape barrier into the reaction vessel. PTFE co-polymer films have been found to exhibit selective permeability towards organic compounds, which was affected by the presence of solvents. In this study, we attempted to establish general trends of permeability of PTFE tape to different compounds and to better describe the process of solvent transport in PV-PTFE bromination reactions. Though PTFE tape has been reported as impermeable to some compounds, such as dimethyl phthalate, solvent adsorption to the tape altered its permeability and allowed diffusion through channels of solvent within the PTFE tape. In this case, the solvent-filled pores of the PTFE tape are chemically more akin to the adsorbed solvent rather than to the PTFE fluorous structure. The solvent uptake effect, which was frequently observed in the course of PV-PTFE reactions, can be related to the surface tension of the solvent and the polarity of the solvent relative to the reagent. The lack of pores in bulk PTFE prevents solvents from altering its permeability and, therefore, bulk PTFE is impermeable to most solvents and reagents. However, bromine, which is soluble in liquid fluorous media, diffused through the bulk PTFE. A better understanding of the PTFE phase barrier will make it possible to further optimize the PV-PTFE reaction design. PMID:26199652

  12. Tape casting as an approach to an all-ceramic turbine shroud seal

    NASA Technical Reports Server (NTRS)

    Cawley, J. D.

    1985-01-01

    Gas path seals have a one-dimensional variation in material requirement. Tape casting is a method which allows the fabrication of thin ceramic sheets, which may be laminated to accommodate these requirements. Using tape casting, thin sheets of zirconia (0.25 mm) were fabricated. These castings were successfully laminated and fired without bloating or delamination, demonstrating the feasibility of this approach.

  13. Classroom Strategies. A Video Tape Bank for English as a Second Language and Adult Basic Education.

    ERIC Educational Resources Information Center

    Hafner, Janet R.; And Others

    Palomar College produced an alternative resource for staff development in the form of a video tape library of demonstration ESL/ABE classroom strategies. The series of 15 tapes offers an inexpensive and easily duplicated means of viewing a variety of methods, an opportunity to select certain methods for repeated viewing, and the opportunity to…

  14. The Taped Problems Intervention: Increasing the Math Fact Fluency of a Student with an Intellectual Disability

    ERIC Educational Resources Information Center

    McCallum, Elizabeth; Schmitt, Ara J.

    2011-01-01

    The Taped Problems intervention is an evidence-based practice that involves a self-monitored, audio-recording procedure in which students follow along with automated recordings of math facts and their solutions. A multiple-probes-across-tasks design was used to evaluate the effectiveness of the Taped Problems intervention on the division-fact…

  15. Manual of Tape Scripts: Italian, Level 2. Curriculum Bulletin, 1969-70 Series, Number 20.

    ERIC Educational Resources Information Center

    Lipton, Gladys; And Others

    This manual of tape scripts, together with a set of foreign language audio tapes for Level 2 Italian, was prepared to support the curriculum bulletin, "New York City Foreign Language Program for Schools: Italian, Levels 1-4." Vocabulary, repetition, transformation, and recombination drills on specific grammatical features allow further development…

  16. Manual of Tape Scripts: Italian, Level 1. Curriculum Bulletin, 1968-69 Series, Number 12.

    ERIC Educational Resources Information Center

    Lipton, Gladys; And Others

    This manual of tape scripts, together with a set of foreign language audio tapes for level 1 Italian, was prepared to support the curriculum bulletin, New York City Foreign Language Program for Schools: Italian, Levels 1-4. Vocabulary, repetition, transformation, and recombination drills on specific grammatical features allow further development…

  17. Manual of Tape Scripts: Spanish, Level 2. Curriculum Bulletin, 1968-69 Series, Number 13.

    ERIC Educational Resources Information Center

    Lipton, Gladys; And Others

    This second manual of tape scripts, together with a set of foreign language audio tapes for level 2 Spanish, was prepared to support the curriculum bulletin, New York City Foreign Language Program for Secondary Schools: Spanish, Levels 1-5. Vocabulary, repetition, transformation, and recombination drills on specific grammatical features allow…

  18. Manual of Tape Scripts: German, Level 1. Curriculum Bulletin, 1968-69 Series, Number 11.

    ERIC Educational Resources Information Center

    Lipton, Gladys; And Others

    This manual of tape scripts, together with a set of foreign language audio tapes for level 1 German, was prepared to support the curriculum bulletin, New York City Foreign Language Program for Secondary Schools: German, Levels 1-4. Vocabulary, repetition, transformation, and recombination drills on specific grammatical features allow further…

  19. Manual of Tape Scripts: French, Level 2. Curriculum Bulletin, 1968-69 Series, Number 10.

    ERIC Educational Resources Information Center

    Lipton, Gladys; And Others

    This second manual of tape scripts, together with a set of foreign language audio tapes for level 2 French, was prepared to support the curriculum bulletin, New York City Foreign Language Program for Secondary Schools: French, Levels 1-5. Vocabulary, repetition, transformation, and recombination drills on specific grammatical features allow…

  20. Manual Tape Scripts: German, Level 2. Curriculum Bulletin, 1969-70 Series, Number 19.

    ERIC Educational Resources Information Center

    Lipton, Gladys; And Others

    This manual of tape scripts, together with a set of foreign language tapes for Level 2 German, was prepared to support the curriculum bulletin "New York City Foreign Language Program for Schools: German, Levels 1-4." Vocabulary, repetition, transformation, and recombination drills on specific grammatical features allow further development of…

  1. 75 FR 57307 - Consolidated Tape Association; Notice of Filing and Immediate Effectiveness of the Fourteenth...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-20

    ..., 1974), 39 FR 17799 (declaring the CTA Plan effective). The CTA Plan, pursuant to which markets collect... COMMISSION Consolidated Tape Association; Notice of Filing and Immediate Effectiveness of the Fourteenth Charges Amendment to the Second Restatement of the Consolidated Tape Association Plan September 14,...

  2. 36 CFR 1275.64 - Reproduction of tape recordings of Presidential conversations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 36 Parks, Forests, and Public Property 3 2013-07-01 2012-07-01 true Reproduction of tape... § 1275.64 Reproduction of tape recordings of Presidential conversations. (a) To ensure the preservation... locations established by the Archivist in accordance with § 1275.62. (d) The reproduction for members of...

  3. 36 CFR 1275.64 - Reproduction of tape recordings of Presidential conversations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 36 Parks, Forests, and Public Property 3 2011-07-01 2011-07-01 false Reproduction of tape... § 1275.64 Reproduction of tape recordings of Presidential conversations. (a) To ensure the preservation... locations established by the Archivist in accordance with § 1275.62. (d) The reproduction for members of...

  4. 36 CFR 1275.64 - Reproduction of tape recordings of Presidential conversations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 36 Parks, Forests, and Public Property 3 2012-07-01 2012-07-01 false Reproduction of tape... § 1275.64 Reproduction of tape recordings of Presidential conversations. (a) To ensure the preservation... locations established by the Archivist in accordance with § 1275.62. (d) The reproduction for members of...

  5. 36 CFR 1275.64 - Reproduction of tape recordings of Presidential conversations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 36 Parks, Forests, and Public Property 3 2014-07-01 2014-07-01 false Reproduction of tape... § 1275.64 Reproduction of tape recordings of Presidential conversations. (a) To ensure the preservation... locations established by the Archivist in accordance with § 1275.62. (d) The reproduction for members of...

  6. 36 CFR 1275.64 - Reproduction of tape recordings of Presidential conversations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Reproduction of tape... § 1275.64 Reproduction of tape recordings of Presidential conversations. (a) To ensure the preservation... locations established by the Archivist in accordance with § 1275.62. (d) The reproduction for members of...

  7. Manual of Tape Scripts: Spanish Level 3. Curriculum Bulletin, 1970-71 Series, Number 10.

    ERIC Educational Resources Information Center

    Lipton, Gladys; And Others

    This publication, together with the audio tapes which it accompanies, was prepared to support the curriculum bulletin, "New York City Foreign Language Program for Secondary Schools: Spanish, Levels 1-5." The scripts in this manual are intended for use in the presentation and drill of the grammatical structures for level 3. The tapes, requiring 10…

  8. Colloidal processing, tape casting and sintering of PLZT for development of piezoceramic/polymer interlayered composites

    NASA Astrophysics Data System (ADS)

    Feng, Jian-Huei

    Piezoceramic/polymer composites possess many advantages as compared to single-phase piezoceramics. One typical form of the composites is the interlayered structure, where the main requirement is to obtain thin, flat and dense ceramic sheets. Tape casting is a reliable process for producing such high-quality sheets. The colloidal processing of tape casting slurries is a critical step to achieve uniform ceramic bodies. Lanthanum-modified lead zirconate titanate (PLZT) was selected for making piezoceramic sheets due to its superior piezoelectric properties. The quality of green tapes depends mainly on the solvents and organic additives of tape casting slurries. The effects of xylenes/ethanol solvent mixtures on non-aqueous slurries were first investigated. Well-dispersed colloidal suspensions were obtained in xylenes-rich solvents with a minimum amount of menhaden fish oil as a dispersant. Adsorption of dispersant and PLZT solids content of unfired tapes are strongly affected by the solvent(s) utilized. Furthermore, when selecting solvent mixtures, one needs to consider other additives, such as binder that can affect the viscosity of slurries. Aqueous tape casting was performed using a polyelectrolyte dispersant, poly(vinyl alcohol) (PVA) binders and various plasticizers. Zeta potential, conductivity and viscosity of PLZT suspensions containing dispersant were characterized. The effects of plasticizers and binders on properties of unfired tapes were also investigated. The tapes made from low molecular weight plasticizers showed higher plasticity. Glycerol was shown to be the most effective plasticizer for PVA. Strong hydrogen bonding in high hydrolysis PVA led to high strength and high bulk density of green tapes, but also caused deformation of the tapes after drying. There are many challenges for sintering PLZT tapes due to volatilization of PbO component at high temperatures and fragility of thin tapes. By using the proper setter powders and the sandwich method

  9. Analysis of data on MADS recorder tape from the STS 51-L Challenger

    NASA Technical Reports Server (NTRS)

    1986-01-01

    Analysis of data from the modular auxiliary data system (MADS) recorder tape from the STS 51-L Challenger following delivery from Marshall Space Flight Center (MSFC). Larue Forbes of CSC retrieves one of the MADS tapes for inputting into a nearby computer in the central data office (30336); Digital data from the MADS tape is sent from Larue Forbes terminal to a hard copy printer in another facility at JSC (30337); Carolyn Watson of Lockheed recieves a hard copy print-out of data from the MADS recorder as it is being sent form the termainal in JSC's central data office (30338); Stan Williams (left) of Lockheed and Luther D. Palmer of NASA are pictured with the MADS tape in JSC's central data office (30339); Larue Forbes of CSC prepares to put one of the MADS tape onto one of the central data office's computers (30340).

  10. TOT 8/4: A Way to Standardize the Surgical Procedure of a Transobturator Tape

    PubMed Central

    Ludwig, Sebastian; Stumm, Martin; Mallmann, Peter; Jager, Wolfram

    2016-01-01

    Suburethral tapes are placed “tension-free” below the urethra. Several studies reported considerable differences of the distance between urethra and tape. These distances ranged from 1 to 10 mm amongst different patients. This either caused urethral obstruction or had no effect on urinary incontinence. Therefore, we decided to standardize the procedure by placing a Hegar dilator of 8-millimeter diameter in the urethra and another Hegar dilator of 4-millimeter diameter between the urethra and the tape during transobturator tape placement. Using that simple technique, which we named “TOT 8/4,” we observed that 83% of the tapes were placed in the desired distance between 3 and 5 millimeters below the urethra. PMID:26981532

  11. Will Duct Tape and Plastic Really Work? Issues Related to Expedient Shelter-In-Place

    SciTech Connect

    Sorensen, J.H.

    2002-08-30

    Expedient sheltering involves the use of common materials to enhance the safety of a room inside a building against the impacts of a chemical plume. The central premise behind taping and sealing with duct tape and plastic is to reduce airflow into a room. This paper reviews issues associated with the use of expedient sheltering materials and the effectiveness of this strategy. Expedient sheltering provides additional protection to people sheltering in place beyond that provided by the house and by a safe room without expedient measures. The materials chosen for taping and sealing--duct tape and plastic--are appropriate because they effectively reduce infiltration and the materials should withstand a vapor challenge. Taping is essential to reduce air infiltration. Plastic sheeting is not a critical element for reducing air infiltration, but it makes sealing off large windows easier.

  12. Feasibility of a short-period superconducting undulator using 2G HTS tapes.

    SciTech Connect

    Kim, S. H.; Doose, C. L.; Jaski, M. S.; Kasa, M. T. )

    2011-06-01

    This paper presents a design concept of a planar-type superconducting undulator (SCU) using YBCO high-temperature superconductor (HTS) tapes. The SCU has a period length of 15 mm, and the tape conductor has dimensions of 4-mm width and 0.1-mm thickness. It has been shown that the conductor transition from one coil groove to the one in the next period is possible by making a semi-circular concave loop of the tape for continuous winding in the same direction. Non-uniform current distribution in the tape may cause field quality degradation. Assuming a uniform current density in the tape, the engineering critical-current density of the HTS in the coil for the design and the corresponding achievable on-axis peak field at 4.2 K were calculated.

  13. Fabrication of YBa2Cu3O7 thin film on cube-textured Cu tape

    NASA Astrophysics Data System (ADS)

    Tokudome, Makoto; Doi, Toshiya; Tomiyasu, Ryota; Sato, Shinya; Hakuraku, Yoshinori; Kubota, Shuichi; Shima, Kunihiro; Kashima, Naoji; Nagaya, Shigeo

    2008-11-01

    We achieved a biaxially oriented YBa2Cu3O7 film on a {100} ⟨001⟩ textured Cu tape with Jc of 1.9×106 A cm-2 at 77 K. A Ni overlayer was deposited by electroplating technique on the {100} ⟨001⟩ textured Cu tape to improve oxidation resistance of Cu substrate, and then YBa2Cu3O7 was deposited on the CeO2/YSZ/CeO2 buffered Ni-electroplated Cu tape. We confirmed that the Ni-electroplated Cu tape lost its ferromagnetism after 700 °C at 1 h heat treatment. Our rolling assisted biaxially textured substrate (RABiTS) type coated conductor can be used for ac applications and is thought to be more cost feasible than the standard RABiTS architecture using Ni-alloy tapes.

  14. Evolution of Archival Storage (from Tape to Memory)

    NASA Technical Reports Server (NTRS)

    Ramapriyan, Hampapuram K.

    2015-01-01

    Over the last three decades, there has been a significant evolution in storage technologies supporting archival of remote sensing data. This section provides a brief survey of how these technologies have evolved. Three main technologies are considered - tape, hard disk and solid state disk. Their historical evolution is traced, summarizing how reductions in cost have helped being able to store larger volumes of data on faster media. The cost per GB of media is only one of the considerations in determining the best approach to archival storage. Active archives generally require faster response to user requests for data than permanent archives. The archive costs have to consider facilities and other capital costs, operations costs, software licenses, utilities costs, etc. For meeting requirements in any organization, typically a mix of technologies is needed.

  15. Generation of ultra-sound during tape peeling

    NASA Astrophysics Data System (ADS)

    Marston, Jeremy O.; Riker, Paul W.; Thoroddsen, Sigurdur T.

    2014-03-01

    We investigate the generation of the screeching sound commonly heard during tape peeling using synchronised high-speed video and audio acquisition. We determine the peak frequencies in the audio spectrum and, in addition to a peak frequency at the upper end of the audible range (around 20 kHz), we find an unexpected strong sound with a high-frequency far above the audible range, typically around 50 kHz. Using the corresponding video data, the origins of the key frequencies are confirmed as being due to the substructure ``fracture'' bands, which we herein observe in both high-speed continuous peeling motions and in the slip phases for stick-slip peeling motions.

  16. Generation of ultra-sound during tape peeling.

    PubMed

    Marston, Jeremy O; Riker, Paul W; Thoroddsen, Sigurdur T

    2014-01-01

    We investigate the generation of the screeching sound commonly heard during tape peeling using synchronised high-speed video and audio acquisition. We determine the peak frequencies in the audio spectrum and, in addition to a peak frequency at the upper end of the audible range (around 20 kHz), we find an unexpected strong sound with a high-frequency far above the audible range, typically around 50 kHz. Using the corresponding video data, the origins of the key frequencies are confirmed as being due to the substructure "fracture" bands, which we herein observe in both high-speed continuous peeling motions and in the slip phases for stick-slip peeling motions. PMID:24651648

  17. Selective laser densification of lithium aluminosilicate glass ceramic tapes

    NASA Astrophysics Data System (ADS)

    Zocca, Andrea; Colombo, Paolo; Günster, Jens; Mühler, Thomas; Heinrich, Jürgen G.

    2013-01-01

    Tapes, cast by blade deposition of a lithium aluminosilicate glass slurry, were sintered using a YAG-fiber laser, with the aim of finding suitable parameters for an additive manufacturing process based on layer-wise slurry deposition and selective laser densification. The influence of the laser parameters (output power and scan velocity) on the sintering was evaluated, by scanning electron microscopy and by X-ray diffraction, on the basis of the quality of the processed layer. Well densified samples could be obtained only in a small window of values for the output power and the scan velocity. The measurement of the width of a set of single scanned lines allowed also to estimate the minimum resolution of the system along the layer plane.

  18. The effectiveness of tape playbacks in estimating Black Rail densities

    USGS Publications Warehouse

    Legare, M.; Eddleman, W.R.; Buckley, P.A.; Kelly, C.

    1999-01-01

    Tape playback is often the only efficient technique to survey for secretive birds. We measured the vocal responses and movements of radio-tagged black rails (Laterallus jamaicensis; 26 M, 17 F) to playback of vocalizations at 2 sites in Florida during the breeding seasons of 1992-95. We used coefficients from logistic regression equations to model probability of a response conditional to the birds' sex. nesting status, distance to playback source, and time of survey. With a probability of 0.811, nonnesting male black rails were ))lost likely to respond to playback, while nesting females were the least likely to respond (probability = 0.189). We used linear regression to determine daily, monthly and annual variation in response from weekly playback surveys along a fixed route during the breeding seasons of 1993-95. Significant sources of variation in the regression model were month (F3.48 = 3.89, P = 0.014), year (F2.48 = 9.37, P < 0.001), temperature (F1.48 = 5.44, P = 0.024), and month X year (F5.48 = 2.69, P = 0.031). The model was highly significant (P < 0.001) and explained 54% of the variation of mean response per survey period (r2 = 0.54). We combined response probability data from radiotagged black rails with playback survey route data to provide a density estimate of 0.25 birds/ha for the St. Johns National Wildlife Refuge. The relation between the number of black rails heard during playback surveys to the actual number present was influenced by a number of variables. We recommend caution when making density estimates from tape playback surveys

  19. LANDSAT-D data format control book. Volume 6, appendix G: GSFC HDT-AM inventory tape (GHIT-AM)

    NASA Technical Reports Server (NTRS)

    1981-01-01

    The data format specifications of the Goddard HDT inventory tapes (GHITS), which accompany shipments of archival digital multispectral scanner image data (HDT-AM tapes), are defined. The GHIT is a nine-track, 1600-BPI tape which conforms to the ANSI standard and serves as an inventory and description of the image data included in the shipment. The archival MSS tapes (HDT-AMs) contain radiometrically corrected but geometrically uncorrected image data plus certain ancillary data necessary to perform the geometric corrections.

  20. An accurate and efficient 3-D micromagnetic simulation of metal evaporated tape

    NASA Astrophysics Data System (ADS)

    Jones, M.; Miles, J. J.

    1997-07-01

    Metal evaporated tape (MET) has a complex column-like structure in which magnetic domains are arranged randomly. In order to accurately simulate the behaviour of MET it is important to capture these aspects of the material in a high-resolution 3-D micromagnetic model. The scale of this problem prohibits the use of traditional scalar computers and leads us to develop algorithms for a vector processor architecture. We demonstrate that despite the materials highly non-uniform structure, it is possible to develop fast vector algorithms for the computation of the magnetostatic interaction field. We do this by splitting the field calculation into near and far components. The near field component is calculated exactly using an efficient vector algorithm, whereas the far field is calculated approximately using a novel fast Fourier transform (FFT) technique. Results are presented which demonstrate that, in practice, the algorithms require sub-O( N log( N)) computation time. In addition results of highly realistic simulation of hysteresis in MET are presented.

  1. Microstructures of YBa2Cu3Oy Layers Deposited on Conductive Layer-Buffered Metal Tapes

    NASA Astrophysics Data System (ADS)

    Ichinose, Ataru; Hashimoto, Masayuki; Horii, Shigeru; Doi, Toshiya

    REBa2Cu3Oy (REBCO; RE: rare-earth elements)-coated conductors (CCs) have high potential for use in superconducting devices. In particular, REBCO CCs are useful for superconducting devices working at relatively high temperatures near 77 K. The important issues in their applications are high performance, reliability and low cost. To date, sufficient performance for some applications has almost been achieved by considerable efforts. The establishment of the reliability of superconducting devices is under way at present. The issue of low cost must be resolved to realize the application of superconducting devices in the near future. Therefore, we have attempted several ways to reduce the cost of REBCO CCs. The coated conductors using a Nb-doped SrTiO3 buffer layer and Ni-plated Cu and stainless steel laminate metal tapes have recently been developed to eliminate the use of electric stabilization layers of Cu and Ag, which are expected to reduce the material cost. Good superconducting properties are obtained at 77 K. The critical current density (JC) at 77 K under a magnetic self-field is determined to be more than 2x106 A/cm2. The microstructures of the CCs are analyzed by transmission electron microscopy to obtain a much higher quality. By microscopic structure analysis, an overgrowth of the buffer layer is observed at a grain boundary of the metal substrate, which is one of the reasons for the high JC.

  2. 77 FR 13263 - Foreign-Trade Zone 109 - Watertown, NY; Amendment to Application; North American Tapes, LLC...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-06

    ... number 48-2011 on July 15, 2011 (76 FR 43259, 7- 20-2011). The NAT facility (25 employees) is located... American Tapes, LLC (Textile Athletic Tape), Watertown, NY A request has been submitted to the Foreign... used to produce pressure-sensitive adhesive athletic tape with textile fabric backing material for...

  3. A magnetically switched kicker for proton extraction

    SciTech Connect

    Dinkel, J.; Biggs, J.

    1989-03-01

    The application of magnetic current amplification and switching techniques to the generation of precise high current pulses for switching magnets is described. The square loop characteristic of Metglas tape wound cores at high excitation levels provides excellent switching characteristics for microsecond pulses. The rugged and passive nature of this type pulser makes it possible to locate the final stages of amplification at the load for maximum efficiency. 12 refs., 8 figs.

  4. Transport ac losses of a second-generation HTS tape with a ferromagnetic substrate and conducting stabilizer

    NASA Astrophysics Data System (ADS)

    Li, Shuo; Chen, Du-Xing; Fang, Jin

    2015-12-01

    The current-voltage curve and transport ac loss of a second-generation HTS tape with a ferromagnetic NiW substrate and brass stabilizer are measured. It is found that the ac loss is up to two orders of magnitude larger than what is expected by the power-law E(J) determined by the current-voltage curve and increases with increasing frequency. Modeling results show that the overly large ac loss is contributed by the ac loss in the HTS strip enhanced by the NiW substrate and the magnetic hysteresis loss in the substrate, and the frequency-dependent loss occurs in the brass layer covering the substrate but not in the ferromagnetic substrate itself as assumed previously. The ac loss in the brass layer is associated with transport currents but not eddy currents, and it has some features similar to ordinary eddy-current loss with significant differences.

  5. CoCrPt-SiO{sub 2} granular-type longitudinal media on Ru underlayer for sputtered tape applications

    SciTech Connect

    Lee, Hwan-Soo; Zhu Jiangang; Laughlin, David E.

    2008-04-01

    CoCrPt-SiO{sub 2} films for use as thin film tape media have been investigated. Bias sputtering and high Ar pressure were utilized to achieve desirable media properties (good in-plane orientation and enhanced grain decoupling) in these media. The in-plane orientation of the bias sputtered CoCrPt-SiO{sub 2} magnetic layer was well maintained even at a high content of SiO{sub 2} as Ru was used as an underlayer and deposited at high Ar pressure. Films of (10.0) textured CoCrPt-SiO{sub 2} on a Ru underlayer showed a large in-plane coercivity of 4000 Oe and transmission electron microscopy revealed an average grain size of about 10 nm, well decoupled by the oxide. The in-plane coercivity was a strong function of the Ru thickness.

  6. Processing and transport properties of high J[sub c] silver clad Bi-2223 tapes and coils

    SciTech Connect

    Haldar, P.; Hoehn, J.G. Jr. ); Balachandran, U. . Materials and Components Technology Div.); Motowidlo, L.R. )

    1993-02-01

    The powder-in-tube process has been used to fabricate long lengths of flexible, high J[sub c], silver clad Bi-2223 HTS conductors. By improving thermo-mechanical processing and precursor powder preparationwe have succeeded in achieving J[sub c]'s exceeding 4 [times] 10[sup 4] A/cm[sup 2] at liquid nitrogen (77K) and > 10[sup 5] A/cm[sup 2] at liquid helium (4.2K) and liquid neon (27K) temperatures for short tapesamples. Detailed measurements with high applied magnetic fields are reported. Several long tapes up to 10 meters in length have also been fabricated and co-wound into small superconducting pancake coils using the wind-and-react'' approach. Transport measurements at 77K and 4.2K for these coils are also reported.

  7. Processing and transport properties of high J{sub c} silver clad Bi-2223 tapes and coils

    SciTech Connect

    Haldar, P.; Hoehn, J.G. Jr.; Balachandran, U.; Motowidlo, L.R.

    1993-02-01

    The powder-in-tube process has been used to fabricate long lengths of flexible, high J{sub c}, silver clad Bi-2223 HTS conductors. By improving thermo-mechanical processing and precursor powder preparationwe have succeeded in achieving J{sub c}`s exceeding 4 {times} 10{sup 4} A/cm{sup 2} at liquid nitrogen (77K) and > 10{sup 5} A/cm{sup 2} at liquid helium (4.2K) and liquid neon (27K) temperatures for short tapesamples. Detailed measurements with high applied magnetic fields are reported. Several long tapes up to 10 meters in length have also been fabricated and co-wound into small superconducting pancake coils using the ``wind-and-react`` approach. Transport measurements at 77K and 4.2K for these coils are also reported.

  8. Heat transfer enhancement of twisted-tape inserts in turbulent pipe flows

    SciTech Connect

    Fujita, Yasunobu; Lopez, A.M.

    1995-12-31

    Experimental data of liquid and vapor flows of R113 for Re = 5,000--400,000 were obtained for both a plain tube and tube with snugly fitted twisted-tape inserts. No evidence of tape fin effects was found in the heat-transfer characteristics of a stainless-steel tape insert when compared to a Teflon-tape insert. For twist ratios {gamma} = 5.9, 10.0, and 16.0, improvements in heat transfer of up to 35 percent were observed. Based on a simple consideration of the heat-transfer enhancement mechanisms of twisted-tape inserts, a Dittus-Boelter-type correlation for a plain tube was modified to include twisted-tape effects. For such a case, use of available plain-tube data were recommended to maximize the accuracy of the proposed correlation. The trade-off between pressure loss and heat-transfer enhancement was considered to determine the overall desirability of twisted-tape inserts.

  9. Modeling of tape tether vibration and vibration sensing using smart film sensors

    NASA Astrophysics Data System (ADS)

    Kunugi, Kouta; Kojima, Hirohisa; Trivailo, Pavel M.

    2015-02-01

    Tape-tethered satellite systems use long and flexible tape tethers, the bending and torsional vibrations of which affect the positions and attitude of attached satellites and climbers. Owing to the distribution characteristics of a tape tether, ordinary point sensors and actuators cannot be used easily to control the vibrations. Other types of sensors and actuators are required for this purpose. The flexibility and deformability of smart materials make them particularly suitable for integration into a tape-tethered system. Thus, in this paper, we propose a method for modeling the bending and torsional vibrations of a tape tether, and report our investigation into the feasibility of using smart film sensors to distinguish between the two vibration types. We formulate equations of motion for the tape tether using multibody dynamics techniques, and perform numerical simulations to study the behavior of the bending and torsional vibrations. The results of our experiments show that the bending and torsional vibrations of a tape tether can be measured using smart film sensors attached to the tether.

  10. Burnout Test of First- and Second-Generation HTS Tapes in Liquid-Nitrogen Bath Cooling

    NASA Astrophysics Data System (ADS)

    Young, M. A.; Demko, J. A.; Duckworth, R. C.; Lue, J. W.; Gouge, M. J.; Pace, M. O.

    2004-06-01

    A series of BSCCO-2223 and YBCO tapes were subjected to burnout tests in a liquid-nitrogen bath to observe operational stability limits when different layers of dielectric tape are added to the sample surface. In this study, the BSCCO tapes were composed of a silver/alloy sheath with nickel/copper plating, while the YBCO tapes had a 50-μm layer of copper attached to the silver surface. After attaching the tapes to a thermally insulated G-10 holder, the stability of the tapes was found by applying current greater than the critical current and holding it constant for up to 1 min. If the sample voltage increased rapidly during this period, the tape was considered unstable at this current. This was repeated at different layers of Cryoflex™, and the results were compared to a numerical simulation of the energy balance equation. This simulation was also utilized to investigate the effect of the layers on the stability limit and estimate the thermal conductivity of the Cryoflex™.

  11. Immediate effects of kinematic taping on lower extremity muscle tone and stiffness in flexible flat feet

    PubMed Central

    Wang, Joong-San; Um, Gi-Mai; Choi, Jung-Hyun

    2016-01-01

    [Purpose] This study aimed to examine the immediate effects of kinematic taping on the tone and stiffness in the leg muscles of subjects with flexible flat feet. [Subjects and Methods] A total of 30 subjects, 15 in the kinematic taping and 15 in the sham taping group, were administered respective taping interventions. Subsequently, the foot pressure and the tone and stiffness in the tibialis anterior, rectus femoris, medial gastrocnemius, and the long head of the biceps femoris muscles of both the lower extremities were measured. [Results] The foot pressure of the dominant leg significantly decreased in the kinematic taping group. The muscle tone and stiffness in the rectus femoris muscle of the dominant and non-dominant leg, tibialis anterior muscle of the dominant leg, medial gastrocnemius muscle of the non-dominant leg, and the stiffness in the dominant leg significantly decreased. The muscle tone and stiffness generally increased in the sham taping group. However, no significant difference was observed between the 2 groups. [Conclusion] This study demonstrated that kinematic taping on flexible flat feet had positive effects of immediately reducing the abnormally increased foot pressure and the tone and stiffness in the lower extremity muscles. PMID:27190479

  12. Rheological property and stress development during drying of tape-cast ceramic layers

    SciTech Connect

    Lewis, J.A.; Blackman, K.A.; Ogden, A.L.; Payne, J.A.; Francis, L.F.

    1996-12-01

    Rheological property and stress development of tape-cast ceramic layers derived from nonaqueous alumina (Al{sub 2}O{sub 3})-poly(vinyl butyral) (PVB) suspensions were observed during drying. Casting suspensions exhibited strong shear-thinning behavior, with a low shear Newtonian plateau apparent viscosity >10{sup 2}Pa{center_dot}s. The apparent suspension viscosity displayed a power-law dependence on the Al{sub 2}O{sub 3} volume fraction during the initial stage of drying ({le}30% solvent loss). Stress development, measured by a cantilever deflection method, and parallel weight loss measurements were performed during the drying of tape-cast layers and pure binder coatings. Maximum drying stresses ({sigma}{sub max}) of 1.37--0.77 MPa were observed for plasticized tapes cast at gap heights of 150--400 {micro}m. In contrast, nonplasticized tapes of similar thickness displayed a more gradual stress increase, with {sigma}{sub max} values approximately an order of magnitude higher than their plasticized counterparts. The stress histories of the corresponding binder coatings were quite similar to the tape-cast layers, albeit slightly lower {sigma}{sub max} values were observed. Stresses decayed beyond {sigma}{sub max} with a logarithmic time dependence to an almost constant value of 0.2--0.4 MPa for the plasticized tapes. Based on these observations, process methodologies have been offered to minimize stress development and retention in tape-cast ceramic layers.

  13. Chemistry of cometary meteoroids from video-tape records of meteor spectra

    NASA Technical Reports Server (NTRS)

    Millman, P. M.

    1982-01-01

    The chemistry of the cometary meteoroids was studied by closed circuit television observing systems. Vidicon cameras produce basic data on standard video tape and enable the recording of the spectra of faint shower meteors, consequently the chemical study is extended to smaller particles and we have a larger data bank than is available from the more conventional method of recording meteor spectra by photography. The two main problems in using video tape meteor spectrum records are: (1) the video tape recording has a much lower resolution than the photographic technique; (2) video tape is relatively new type of data storage in astronomy and the methods of quantitative photometry have not yet been fully developed in the various fields where video tape is used. The use of the most detailed photographic meteor spectra to calibrate the video tape records and to make positive identification of the more prominent chemical elements appearing in the spectra may solve the low resolution problem. Progress in the development of standard photometric techniques for the analysis of video tape records of meteor spectra is reported.

  14. Effects of spiral taping applied to the neck and ankle on the body balance index

    PubMed Central

    Lee, Byung Hoon; Lee, Hye Rim; Kim, Kyeong Mi; Lee, Jeong Hun; Kim, Kyung Yoon

    2015-01-01

    [Purpose] This study was performed to investigate the changes in the body balance index when spiral taping is applied to the neck and ankle. The findings are expected to serve as evidence of the usefulness of taping the neck instead of the ankle when ankle taping is not feasible in clinical practice. [Subjects and Methods] Twenty healthy male students at A university were enrolled in this study. Balance measurements were made under three conditions: no intervention, ankle intervention and neck intervention. Static balance was measured with subjects’ eyes open and closed, and dynamic balance was measured with subjects’ eyes closed. [Results] There were significant differences in dynamic balance assessed by the Overall Balance Index (OBI), and the Anteroposterior Balance Index (ABI) with subjects’ eyes open when ankle or neck taping was applied compared to no intervention. The static balance (OBI) of subjects with eyes open showed significant differences from the no intervention condition in both the ankle and neck intervention. The static balance (OBI) with subjects’ eyes closed also showed significant differences in both the ankle and neck interventions compared to the no intervention condition. [Conclusion] Our results indicate that neck taping stimulates the somatic senses around the neck and increase proprioception, resulting in balance improvement similar to that elicited by ankle taping. Further studies with larger sample sizes various experimental conditions should be performed to more systematically and objectively elucidate the effects of neck taping. PMID:25642043

  15. Thermal Edge-Effects Model for Automated Tape Placement of Thermoplastic Composites

    NASA Technical Reports Server (NTRS)

    Costen, Robert C.

    2000-01-01

    Two-dimensional thermal models for automated tape placement (ATP) of thermoplastic composites neglect the diffusive heat transport that occurs between the newly placed tape and the cool substrate beside it. Such lateral transport can cool the tape edges prematurely and weaken the bond. The three-dimensional, steady state, thermal transport equation is solved by the Green's function method for a tape of finite width being placed on an infinitely wide substrate. The isotherm for the glass transition temperature on the weld interface is used to determine the distance inward from the tape edge that is prematurely cooled, called the cooling incursion Delta a. For the Langley ATP robot, Delta a = 0.4 mm for a unidirectional lay-up of PEEK/carbon fiber composite, and Delta a = 1.2 mm for an isotropic lay-up. A formula for Delta a is developed and applied to a wide range of operating conditions. A surprise finding is that Delta a need not decrease as the Peclet number Pe becomes very large, where Pe is the dimensionless ratio of inertial to diffusive heat transport. Conformable rollers that increase the consolidation length would also increase Delta a, unless other changes are made, such as proportionally increasing the material speed. To compensate for premature edge cooling, the thermal input could be extended past the tape edges by the amount Delta a. This method should help achieve uniform weld strength and crystallinity across the width of the tape.

  16. Characterizing acrylic pressure-sensitive adhesive tapes favoring diverse biomedical applications

    NASA Astrophysics Data System (ADS)

    Alhijji, Saleh Mohammed S.

    Strong, self-adhesive acrylic polymer-based tapes have been identified as FDA-approved medical device construction components that might also serve in diverse biological locations as artificial muscles, ligaments, or compressive support discs. After assuring that the tapes themselves were not cytotoxic, they were evaluated as possible low-tension muscle substitutes for eyelids, jaws, and other modest body re-closing needs, and well as for higher-tension applications as artificial ligaments. Self-adhesion of the tapes to representative biomaterials, before and after radio-frequency glow discharge treatment for surface energy modification, illustrated the conditions for maximum attachment strength to nonphysiologic substances. Attachment to bony host parts was challenging but apparently met by the application of acrylic-composite-to-dentin bonding systems that has shown good long-term experience in the mouth. Above all, the compression-relaxation properties of the tape materials were superior and their uses in potential Nucleus Pulposus applications for spinal disc repair were most completely explored. Tests included tape-disc performance longevity, both dry and wet, for over 5000 load-relaxation cycles, with no apparent changes in results for the most dense of the tapes evaluated. Direct abrasion was avoided by insertion of rigid polymeric layers. It is recommended that the compressive loading properties of acrylic tapes be further evaluated for spine repair applications.

  17. Designing HTS coils for magnetic circuits

    SciTech Connect

    Jenkins, R.G.; Jones, H.; Goodall, R.M.

    1996-07-01

    The authors discuss some of the main considerations involved in the design of HTS coils to operate in liquid nitrogen and provide ampere-turns for magnetic circuits in general, and then in particular for a small-scale electromagnetic (i.e, attractive) maglev demonstrator. The most important factor affecting design is the sensitive and strongly anisotropic dependence of HTS tape`s critical current on magnetic field. Any successful design must limit the field in the windings, especially components perpendicular to the tape`s surface (radial components in the case of solenoids), to acceptably low levels such that local critical currents nowhere fall below the operating current. This factor is relevant to the construction of HTS coils for all applications. A second important factor is that the presence of an iron magnetic circuit can greatly alter the flux distribution within the coils from that found when they are in free space. FE modelling has been used to calculate accurate field profiles in proposed designs for comparison with short sample I{sub c}(B) data. They present a design for a maglev demonstrator, illustrating how some of the problems, in particular the reduction of radial field components, may be addressed, and describe its predicted performance.

  18. High critical currents in heavily doped (Gd,Y)Ba{sub 2}Cu{sub 3}O{sub x} superconductor tapes

    SciTech Connect

    Selvamanickam, V. Gharahcheshmeh, M. Heydari; Xu, A.; Galstyan, E.; Delgado, L.; Cantoni, C.

    2015-01-19

    REBa{sub 2}Cu{sub 3}O{sub x} ((REBCO), RE = rare earth) superconductor tapes with moderate levels of dopants have been optimized for high critical current density in low magnetic fields at 77 K, but they do not exhibit exemplary performance in conditions of interest for practical applications, i.e., temperatures less than 50 K and fields of 2–30 T. Heavy doping of REBCO tapes has been avoided by researchers thus far due to deterioration in properties. Here, we report achievement of critical current densities (J{sub c}) above 20 MA/cm{sup 2} at 30 K, 3 T in heavily doped (25 mol. % Zr-added) (Gd,Y)Ba{sub 2}Cu{sub 3}O{sub x} superconductor tapes, which is more than three times higher than the J{sub c} typically obtained in moderately doped tapes. Pinning force levels above 1000 GN/m{sup 3} have also been attained at 20 K. A composition map of lift factor in J{sub c} (ratio of J{sub c} at 30 K, 3 T to the J{sub c} at 77 K, 0 T) has been developed which reveals the optimum film composition to obtain lift factors above six, which is thrice the typical value. A highly c-axis aligned BaZrO{sub 3} (BZO) nanocolumn defect density of nearly 7 × 10{sup 11 }cm{sup −2} as well as 2–3 nm sized particles rich in Cu and Zr have been found in the high J{sub c} films.

  19. High critical currents in heavily doped (Gd,Y)Ba2Cu3Ox superconductor tapes

    SciTech Connect

    Selvamanickam, V.; Gharahcheshmeh, M. Heydari; Xu, A.; Galstyan, E.; Delgado, L.; Cantoni, C.

    2015-01-20

    REBa2Cu3Ox superconductor tapes with moderate levels of dopants have been optimized for high critical current density in low magnetic fields at 77 K, but they do not exhibit exemplary performance in conditions of interest for practical applications, i.e., temperatures less than 50 K and fields of 2–30 T. Heavy doping of REBCO tapes has been avoided by researchers thus far due to deterioration in properties. Here, we report achievement of critical current densities (Jc) above 20 MA/cm2 at 30 K, 3 T in heavily doped (25 mol. % Zr-added) (Gd,Y)Ba2Cu3Ox superconductor tapes, which is more than three times higher than the Jc typically obtained in moderately doped tapes. Pinning force levels above 1000 GN/m3 have also been attained at 20 K. A composition map of lift factor in Jc (ratio of Jc at 30 K, 3 T to the Jc at 77 K, 0 T) has been developed which reveals the optimum film composition to obtain lift factors above six, which is thrice the typical value. A highly c-axis aligned BaZrO3 (BZO) nanocolumn defect density of nearly 7 × 1011 cm–2 as well as 2–3nm sized particles rich in Cu and Zr have been found in the high Jc films.

  20. Evaluation of the ShapeTape for studying biomechanics in the workplace.

    PubMed

    Harley, Linda R; Grullon, Sergio A; Harbert, Simeon D; Holmes, Jonathan; Britton, Douglas F

    2012-01-01

    Motion capture systems may be difficult to use in harsh environments such as a poultry plant, and therefore should be self-contained, portable, unobtrusive, and not interfere with or be degraded by plant machinery or processes. The purpose of this study was to evaluate the validity, reliability and accuracy of the ShapeTape system as a potential solution. This was accomplished by comparing kinematic data from the ShapeTape against the Vicon system. Subjects performed cyclical movements along a plane angled 45° up from the horizontal using their right arms. Results revealed that the ShapeTape kinematic data was significantly larger than the Vicon data, yet statistically reliable.