Science.gov

Sample records for 96-well microtitre plates

  1. Electrothermal micromixing in 96 well plate

    NASA Astrophysics Data System (ADS)

    Kauffmann, Paul; Loire, Sophie; Mezic, Igor

    2011-11-01

    Diagnostic and pharmacology processes could be greatly accelerated by appropriate mixing. Here electrothermal flows are explored to provide mixing of conductive physiological solutions (=1.6 S/m) in a 96 well plate. Three interdigitated electrodes provide an electric field (< 15Vpp, 1MHz) beneath each well. Polarization and conduction phenomenon of the fluid in a well will be first modeled numerically and compared to an electrical circuit model. Due to high conductivity and permittivity of the fluid, the impedance of the array of filled wells collapse dramatically (96 wells: R = 1Ohm, C=250nF). The power supply challenges accordingly raised by arrays of electrothermal micromixers will be then analyzed. The efficiency of different methods of mixing in those wells will be also compared: the addition of low frequency signal leading to AC electro-osmotic perturbations, a blinking vortices method. The experimental results will be compared to simulations.

  2. Quantification of cells cultured on 96-well plates.

    PubMed

    Kueng, W; Silber, E; Eppenberger, U

    1989-10-01

    The method for cell number measurement in monolayer cultures by crystal violet staining published recently by Gillies et al. (R. G. Gillies, N. Didier, M. Denton (1986) Anal. Biochem. 159, 109-113) was modified and significantly improved. The procedure was adapted for use in 96-well plates since the method is inherently very sensitive. Modifications allowed fast and complete solubilization of dye adsorbed by cell nuclei during staining. Since light absorption of the unstained or destained cell layers is negligible, cell number measurements can be performed in the respective wells. Due to these features, multiple assays may be carried out rapidly using standard 96-well plate readers. In addition, it is shown that the sensitivity of the assay can be varied and easily controlled by choosing the appropriate pH during the staining procedure. This increases the flexibility of the method making it useful for determining cell density of a wide range of different cell types. PMID:2604040

  3. A high-capacity streptavidin-coated microtitration plate.

    PubMed

    Välimaa, Lasse; Pettersson, Kim; Vehniäinen, Markus; Karp, Matti; Lövgren, Timo

    2003-01-01

    A majority of current immunoassays rely on capturing a specific analyte on a solid phase to allow the separation of the bound analyte from nonbound components. Streptavidin-coated microtitration plates are widely used for immobilization of capturing antibodies, since they provide a generic surface for immobilization of any biotinylated molecule and preserve biomolecule activity much better than direct passive adsorption. Our trials to further improve the properties of the plates resulted in a development of a modified plate, which has higher binding capacity than currently used control plate. The modified coat was prepared by cross-linking streptavidin chemically prior to adsorption onto the microtitration well surfaces. The binding capacities of the plates were measured with biotinylated, europium-labeled molecules and labeled antigen. The immunoassay performance of the plates was studied with noncompetitive, sandwich-type assays of prostate specific antigen (PSA) and human chorionic gonadotropin (hCG). The maximum immobilization capacity of the modified plate was up to 2.5 times higher than that of the control plate. The higher binding capacity was especially emphasized with small-size molecules. The modified high capacity plate increased the linear ranges of the immunoassays and thus delayed the high-dose hook effect. At high antigen concentrations the signal increased up to 59%, and at the conventional linear ranges of the assays, the increase was up to 29%. We conclude that the modified coating method will be valuable for the future miniaturized systems, where high immobilization capacity is needed at limited areas. PMID:12526699

  4. Lactobacillus casei microbiological assay of folic acid derivatives in 96-well microtiter plates.

    PubMed

    Horne, D W; Patterson, D

    1988-11-01

    Microbiological assay is still widely used for estimating folic acid derivatives in serum and other biological samples. We describe here a modification of this procedure involving use of 96-well microtiter plates. This procedure, used with modern, computer-interfaced microtiter-plate readers and data-reduction software, greatly shortens the time and minimizes reagent costs for this assay. Under the conditions of our assay procedures, all folic acid derivatives tested gave equal growth response for Lactobacillus casei. Results for assays of rat liver extracts showed excellent agreement between the standard bioassay and the 96-well procedure. PMID:3141087

  5. HIGHLY SENSITIVE ASSAY FOR ANTICHOLINESTERASE COMPOUNDS USING 96 WELL PLATE FORMAT

    EPA Science Inventory

    The rapid and sensitive detection of organophosphate insecticides using a 96 well plate format is reported. Several features of this assay make it attractive for development as a laboratory-based or field screening assay. Acetylcholinesterase (AChE) was stabilized in a gelati...

  6. Biofilm Localization in the Vertical Wall of Shaking 96-Well Plates

    PubMed Central

    Gomes, Luciana C.; Moreira, Joana M. R.; Simões, Manuel; Melo, Luís F.; Mergulhão, Filipe J.

    2014-01-01

    Microtiter plates with 96 wells are being increasingly used for biofilm studies due to their high throughput, low cost, easy handling, and easy application of several analytical methods to evaluate different biofilm parameters. These methods provide bulk information about the biofilm formed in each well but lack in detail, namely, regarding the spatial location of the biofilms. This location can be obtained by microscopy observation using optical and electron microscopes, but these techniques have lower throughput and higher cost and are subjected to equipment availability. This work describes a differential crystal violet (CV) staining method that enabled the determination of the spatial location of Escherichia coli biofilms formed in the vertical wall of shaking 96-well plates. It was shown that the biofilms were unevenly distributed on the wall with denser cell accumulation near the air-liquid interface. The results were corroborated by scanning electron microscopy and a correlation was found between biofilm accumulation and the wall shear strain rates determined by computational fluid dynamics. The developed method is quicker and less expensive and has a higher throughput than the existing methods available for spatial location of biofilms in microtiter plates. PMID:24834360

  7. Stability test for amorphous materials in humidity controlled 96-well plates by near-infrared spectroscopy.

    PubMed

    Otsuka, Makoto; Tanabe, Hideaki

    2012-03-01

    The purpose of this research is to apply near infrared spectrometry (NIR) with chemoinformetrics to predict the change of crystalline properties of indomethacin (IMC) amorphous under various levels of relative humidity storage conditions. Stability test for amorphous and meta-stable polymorphic forms was performed in humidity controlled the modified 96-well quartz plates containing various kinds of saturated salt solutions (0-100% of relative humidity (RH)) by NIR spectroscopy. Amorphous form was obtained melt product to pour into liquid nitrogen and after then ground. Samples were stored at 25°C in the 6-well plates at various levels of RH. The spectra of the powder samples were measured by the reflectance FT-NIR spectrometer. The second derivative spectra of form α showed specific absorption peaks at 4980, 6036, 7296 and 8616 cm-1 and that of form γ showed those at 5020, 5028, 7344, 7428 and 8436 cm-1. After storage at less than 50% RH, the peak intensities at 5020, 5028, 7344, 7428 and 8436 cm-1 of the amorphous solid increased with increasing of storage time. However, the peak intensity at 4980, 6036 and 7296 cm-1 increased at more than 50% RH Please check and confirm the edit. The results suggested that at lower humidity, the IMC amorphous solid transformed into form γ, but it transformed into form α at more than high humidity. It is possible that crystalline stability of the pharmaceutical preparations could be predicted by using humidity controlled 96-well plates and reflectance NIR-chemoinformetric methods. PMID:21942281

  8. Measuring oxidative stress resistance of Caenorhabditis elegans in 96-well microtiter plates.

    PubMed

    Possik, Elite; Pause, Arnim

    2015-01-01

    Oxidative stress, which is the result of an imbalance between production and detoxification of reactive oxygen species, is a major contributor to chronic human disorders, including cardiovascular and neurodegenerative diseases, diabetes, aging, and cancer. Therefore, it is important to study oxidative stress not only in cell systems but also using whole organisms. C. elegans is an attractive model organism to study the genetics of oxidative stress signal transduction pathways, which are highly evolutionarily conserved. Here, we provide a protocol to measure oxidative stress resistance in C. elegans in liquid. Briefly, ROS-inducing reagents such as paraquat (PQ) and H2O2 are dissolved in M9 buffer, and solutions are aliquoted in the wells of a 96 well microtiter plate. Synchronized L4/young adult C. elegans animals are transferred to the wells (5-8 animals/well) and survival is measured every hour until most worms are dead. When performing an oxidative stress resistance assay using a low concentration of stressors in plates, aging might influence the behavior of animals upon oxidative stress, which could lead to an incorrect interpretation of the data. However, in the assay described herein, this problem is unlikely to occur since only L4/young adult animals are being used. Moreover, this protocol is inexpensive and results are obtained in one day, which renders this technique attractive for genetic screens. Overall, this will help to understand oxidative stress signal transduction pathways, which could be translated into better characterization of oxidative stress-associated human disorders. PMID:25993260

  9. A rapid direct telomerase assay method using 96-well streptavidin plates.

    PubMed

    Francis, Rawle; Friedman, Simon H

    2002-05-01

    We have developed a high-throughput direct assay methodfor the assay of telomerase activity that improves on previous direct telomerase assays in two ways that allow larger numbers of samples to be conveniently processed: (i) 96-well streptavidin coated plates are used to bind and wash biotinylated primer extension products from the telomerase assay, as opposed to tubes containing streptavidin-coated magnetic beads; and (ii) storage phosphor-imagery is used instead of film autoradiography to detect telomerase products after being washed and released from the streptavidin-derivatized matrix. This method improves on previous direct assay methods using magnetic beads by allowing larger numbers of samples to be conveniently assayed. Also, the total activity of the radiolabeled nucleotides used in this procedure is significantly lower than that used in standard direct telomerase assays, lowering costs and exposure to radioactivity. We have validated the assay by repeating, in triplicate, the IC50 determination of rivanol, our previously identified telomerase inhibitor. PMID:12019789

  10. Establishment of ATP-based luciferase viability assay in 96-well plate for Trypanosoma congolense.

    PubMed

    Suganuma, Keisuke; Allamanda, Puttik; Hakimi, Hassan; Zhou, Mo; Angeles, Jose Ma; Kawazu, Shin-ichiro; Inoue, Noboru

    2014-11-01

    Animal African trypanosomosis (AAT), caused by Trypanosoma congolense, is widespread throughout sub-Saharan Africa. There are significant concerns related to the current drugs available for the treatment of AAT due to their limited effectiveness across species and their adverse effects. Moreover, drug resistant trypanosomes have recently been reported in the field. High throughput screening (HTS) of large chemical compound library collections is a promising approach for identifying novel drug candidates. While HTS for Trypanozoon trypanosomes, T. brucei sspp. and T. evansi is well established, no assays have been developed for T. congolense. In the present study, the authors developed an ATP-based luciferase viability assay for T. congolense in a 96-well plate format. The calculated 50% inhibitory concentration (IC50) values for pentamidine and diminazene were 10-100 times higher in T. congolense than in T. brucei. This result suggests that the transporters for the 2 tested compounds differ between T. congolense and T. brucei. This assay could further be applied to screen novel chemical compounds for the treatment of AAT caused by T. congolense. PMID:25056575

  11. Establishment of ATP-Based Luciferase Viability Assay in 96-Well Plate for Trypanosoma congolense

    PubMed Central

    SUGANUMA, Keisuke; ALLAMANDA, Puttik; HAKIMI, Hassan; ZHOU, Mo; ANGELES, Jose Ma.; KAWAZU, Shin-ichiro; INOUE, Noboru

    2014-01-01

    ABSTRACT Animal African trypanosomosis (AAT), caused by Trypanosoma congolense, is widespread throughout sub-Saharan Africa. There are significant concerns related to the current drugs available for the treatment of AAT due to their limited effectiveness across species and their adverse effects. Moreover, drug resistant trypanosomes have recently been reported in the field. High throughput screening (HTS) of large chemical compound library collections is a promising approach for identifying novel drug candidates. While HTS for Trypanozoon trypanosomes, T. brucei sspp. and T. evansi is well established, no assays have been developed for T. congolense. In the present study, the authors developed an ATP-based luciferase viability assay for T. congolense in a 96-well plate format. The calculated 50% inhibitory concentration (IC50) values for pentamidine and diminazene were 10–100 times higher in T. congolense than in T. brucei. This result suggests that the transporters for the 2 tested compounds differ between T. congolense and T. brucei. This assay could further be applied to screen novel chemical compounds for the treatment of AAT caused by T. congolense. PMID:25056575

  12. Urine sample preparation in 96-well filter plates for quantitative clinical proteomics.

    PubMed

    Yu, Yanbao; Suh, Moo-Jin; Sikorski, Patricia; Kwon, Keehwan; Nelson, Karen E; Pieper, Rembert

    2014-06-01

    Urine is an important, noninvasively collected body fluid source for the diagnosis and prognosis of human diseases. Liquid chromatography mass spectrometry (LC-MS) based shotgun proteomics has evolved as a sensitive and informative technique to discover candidate disease biomarkers from urine specimens. Filter-aided sample preparation (FASP) generates peptide samples from protein mixtures of cell lysate or body fluid origin. Here, we describe a FASP method adapted to 96-well filter plates, named 96FASP. Soluble urine concentrates containing ~10 μg of total protein were processed by 96FASP and LC-MS resulting in 700-900 protein identifications at a 1% false discovery rate (FDR). The experimental repeatability, as assessed by label-free quantification and Pearson correlation analysis for shared proteins among replicates, was high (R ≥ 0.97). Application to urinary pellet lysates which is of particular interest in the context of urinary tract infection analysis was also demonstrated. On average, 1700 proteins (±398) were identified in five experiments. In a pilot study using 96FASP for analysis of eight soluble urine samples, we demonstrated that protein profiles of technical replicates invariably clustered; the protein profiles for distinct urine donors were very different from each other. Robust, highly parallel methods to generate peptide mixtures from urine and other body fluids are critical to increase cost-effectiveness in clinical proteomics projects. This 96FASP method has potential to become a gold standard for high-throughput quantitative clinical proteomics. PMID:24797144

  13. Toward Microbioreactor Arrays: A Slow-Responding Oxygen Sensor for Monitoring of Microbial Cultures in Standard 96-Well Plates.

    PubMed

    Glauche, Florian; John, Gernot T; Arain, Sarina; Knepper, Andreas; Neubauer, Antje; Goelling, Detlef; Lang, Christine; Violet, Norman; King, Rudibert; Neubauer, Peter

    2015-08-01

    In this study, a slow-responding chemo-optical sensor for dissolved oxygen (DO) integrated into a 96-well plate was developed. The slow response time ensures that the measured oxygen value does not change much during plate transport to the microplate reader. The sensor therefore permits at-line DO measurement of microbial cultures. Moreover, it eliminates the necessity of individual optical measurement systems for each culture plate, as many plates can be measured successively. Combined with the 96-well format, this increases the experimental throughput enormously. The novel sensor plate (Slow OxoPlate) consists of fluorophores suspended in a polymer matrix that were placed into u-bottom 96-well plates. Response time was measured using sodium sulfite, and a t90 value of 9.7 min was recorded. For application, DO values were then measured in Escherichia coli and Saccharomyces cerevisiae cultures grown under fed-batch-like conditions. Depending on the DO sensor's response time, different information on the oxygenation state of the culture plate was obtained: a fast sensor variant detects disturbance through sampling, whereas the slow sensor indicates oxygen limitation during incubation. A combination of the commercially available OxoPlate and the Slow OxoPlate enables operators of screening facilities to validate their cultivation procedures with regard to oxygen availability. PMID:25720599

  14. Microtitration plate enzyme immunoassay to detect PCR-amplified DNA from Candida species in blood.

    PubMed Central

    Fujita, S; Lasker, B A; Lott, T J; Reiss, E; Morrison, C J

    1995-01-01

    We developed a microtitration plate enzyme immunoassay to detect PCR-amplified DNA from Candida species. Nucleotide sequences derived from the internal transcribed spacer (ITS) region of fungal rDNA were used to develop species-specific oligonucleotide probes for Candida albicans, C. tropicalis, C. parapsilosis, and C. krusei. No cross-hybridization was detected with any other fungal, bacterial, or human DNAs tested. In contrast, a C. (Torulopsis) glabrata probe cross-reacted with Saccharomyces cerevisiae DNA but with no other DNAs tested. Genomic DNA purified from C. albicans blastoconidia suspended in blood was amplified by PCR with fungus-specific universal primers ITS3 and ITS4. With the C. albicans-specific probe labeled with digoxigenin, a biotinylated capture probe, and streptavidin-coated microtitration plates, amplified DNA from a few as two C. albicans cells per 0.2 ml of blood could be detected by enzyme immunoassay. PMID:7790469

  15. Ice-Cap: a method for growing Arabidopsis and tomato plants in 96-well plates for high-throughput genotyping.

    PubMed

    Su, Shih-Heng; Clark, Katie A; Gibbs, Nicole M; Bush, Susan M; Krysan, Patrick J

    2011-01-01

    It is becoming common for plant scientists to develop projects that require the genotyping of large numbers of plants. The first step in any genotyping project is to collect a tissue sample from each individual plant. The traditional approach to this task is to sample plants one-at-a-time. If one wishes to genotype hundreds or thousands of individuals, however, using this strategy results in a significant bottleneck in the genotyping pipeline. The Ice-Cap method that we describe here provides a high-throughput solution to this challenge by allowing one scientist to collect tissue from several thousand seedlings in a single day (1,2). This level of throughput is made possible by the fact that tissue is harvested from plants 96-at-a-time, rather than one-at-a-time. The Ice-Cap method provides an integrated platform for performing seedling growth, tissue harvest, and DNA extraction. The basis for Ice-Cap is the growth of seedlings in a stacked pair of 96-well plates. The wells of the upper plate contain plugs of agar growth media on which individual seedlings germinate. The roots grow down through the agar media, exit the upper plate through a hole, and pass into a lower plate containing water. To harvest tissue for DNA extraction, the water in the lower plate containing root tissue is rapidly frozen while the seedlings in the upper plate remain at room temperature. The upper plate is then peeled away from the lower plate, yielding one plate with 96 root tissue samples frozen in ice and one plate with 96 viable seedlings. The technique is named "Ice-Cap" because it uses ice to capture the root tissue. The 96-well plate containing the seedlings can then wrapped in foil and transferred to low temperature. This process suspends further growth of the seedlings, but does not affect their viability. Once genotype analysis has been completed, seedlings with the desired genotype can be transferred from the 96-well plate to soil for further propagation. We have demonstrated

  16. MStern Blotting-High Throughput Polyvinylidene Fluoride (PVDF) Membrane-Based Proteomic Sample Preparation for 96-Well Plates.

    PubMed

    Berger, Sebastian T; Ahmed, Saima; Muntel, Jan; Cuevas Polo, Nerea; Bachur, Richard; Kentsis, Alex; Steen, Judith; Steen, Hanno

    2015-10-01

    We describe a 96-well plate compatible membrane-based proteomic sample processing method, which enables the complete processing of 96 samples (or multiples thereof) within a single workday. This method uses a large-pore hydrophobic PVDF membrane that efficiently adsorbs proteins, resulting in fast liquid transfer through the membrane and significantly reduced sample processing times. Low liquid transfer speeds have prevented the useful 96-well plate implementation of FASP as a widely used membrane-based proteomic sample processing method. We validated our approach on whole-cell lysate and urine and cerebrospinal fluid as clinically relevant body fluids. Without compromising peptide and protein identification, our method uses a vacuum manifold and circumvents the need for digest desalting, making our processing method compatible with standard liquid handling robots. In summary, our new method maintains the strengths of FASP and simultaneously overcomes one of the major limitations of FASP without compromising protein identification and quantification. PMID:26223766

  17. IDENTIFICATION OF SALMONELLA-POSITIVE FECAL SAMPLES USING A 96-WELL MICROCULTURE PLATE TECHNIQUE (RX METHOD)

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Conventional Salmonella isolation involves multiple sample transfers to culture media performed by an experienced microbiologist. The modified semi-solid RV and XLT (RX) Plate method, a modification of the RX tube format designed by Gailey et al. (2004), consolidates pre-enrichment (buffered pepton...

  18. SIMPLE DEVICE TO DELIVER BEADS TO 96-WELL PLATES FOR RAPID RESUSPENSION OF CELLS

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Genomic sequencing involves sequence determination of inserts from a large numbers of plasmids of a genomic library. In high throughput DNA sequencing projects, cultures are grown in a 96-deep well plate format, centrifuged, and resuspended. Resuspension of cells was aided by use of a simple devic...

  19. Human tear analysis with miniaturized multiplex cytokine assay on “wall-less” 96-well plate

    PubMed Central

    Quah, Joanne; Tong, Louis; Kim, Namyong

    2015-01-01

    Purpose Tears are a particularly limited body fluid and commonly used in the diagnosis of patients who have ocular diseases. A popular method for analysis of ocular inflammation in tears uses Luminex® bead multiplex technology to generate valuable multiple cytokine profile outputs with 25–50 µl tear sample volume. We propose a method for measuring tear cytokines with 5 μl tear sample volume and 80% reduced Luminex reagents compared to previous protocols. Methods Using human tears pooled from 1,000 participants, the DA-Bead-based method running at 5–20 µl volume, using manual pipetting, in conjunction with a magnetic Luminex cytokine (four-plex) panel assay in a 96-well format was performed and validated for tumor necrosis factor (TNF)-α, interferon (IFN)-γ, interleukin (IL)-1β, and IL-6. Results Upon use of the DA-Bead method at the 5 μl volume with cytokine standards, the concentrations of each of the four cytokines were found to be linear over a range of 3.5–4 log pg/ml with an intra-assay coefficient of variation (CV) ≤5%, inter-assay %CV ≤10%, and accuracy within the 70–130% range. Upon use of a 5 µl healthy pooled tear sample, cytokine concentrations were detected with a precision intra-assay %CV ˂ 20% for IL-6, IFN-γ, or TNF-α or 30.37% with IL-1β. The inter-assay %CV with tears was ≤20.84% for all cytokines. Tear volumes run at 5 μl on DA-Bead produced a similar cytokine expression profile at a 1-month interval and were highly correlated with the larger 10 μl–based tear sample volume cytokine profile with R2 = 0.98. Conclusions DA-Bead assay is highly sensitive and reproducible and has a performance profile that is potentially suitable for use in standard clinical scenarios. Considering the use of as little as 5 µl of assay beads and 5 µl sample, this is also likely to reduce the assay cost significantly and ease diagnosis of patients with ocular diseases. PMID:26539027

  20. Is biofilm removal properly assessed? Comparison of different quantification methods in a 96-well plate system.

    PubMed

    Stiefel, Philipp; Rosenberg, Urs; Schneider, Jana; Mauerhofer, Stefan; Maniura-Weber, Katharina; Ren, Qun

    2016-05-01

    Various methods have been reported to quantify total biofilm or different components of biofilm; however, these methods are often confusedly used, leading to discrepancies and misleading results. In this study, different methods for quantification of biofilm, including those for total biomass, total amount of bacterial cells, viable cell number, and amount of extracellular polymeric substances, were systematically compared in microtiter plates. To evaluate which method is suitable for assessment of biofilm removal and for bacterial killing, biofilm samples were treated with various cleaners possessing removing and/or killing capacities. It was found that most of the methods tested in this study in general exhibited high reproducibility and repeatability. Crystal Violet staining was a simple but reliable method for total biomass quantification. Total bacteria cell numbers could be reliably quantified by the fluorescent DNA-binding dye Acridine Orange. Viable cells could be quantified by either an ATP-based assay or a proliferation assay. Both of these viability methods showed a broad detection range and led to precise measurement. For quantification of proteins in the biofilm, staining with fluorescein isothiocyanate was most suitable. Furthermore, it was revealed that a combination of different methods is required to determine if a cleaner kills or removes biofilm. PMID:26923144

  1. Development of a novel bead-based 96-well filtration plate competitive immunoassay for the detection of Gentamycin.

    PubMed

    Ho, Tien Yu Jessica; Chan, Chia-Chung; Chan, KinGho; Wang, Yu Chieh; Lin, Jing-Tang; Chang, Cheng-Ming; Chen, Chien-Sheng

    2013-11-15

    We developed a sensitive, simple, inexpensive and rapid bead-based immunoassay platform, composed of liposomal nanovesicle amplification system, Gentamycin sulfate beads and 96-well filtration plates. In the beginning of the assay, Gentamycin sulfate beads, Gentamycin sulfate and Gentamycin specific antibody were incubated in a bottom-sealed 96-well filtration plate. After incubation, washing was done by running washing buffer through the unsealed filtration plate with only gravity and the antibody-Gentamycin bead complexes were retained in the plate. Fluorescent dye-loaded protein G-liposomal nanovesicles were then added to specifically bind to antibodies on the retained beads. After washing unbound nanovesicles, millions of fluorescent dye molecules were released by adding a detergent solution to lyse liposomal nanovesicles. The limit of detection (LOD) of this novel detection platform in TBS and in skim milk were 52.65 ng/mL and 14.16 ng/mL, which are both sufficient for detecting the 200 ng/mL Codex maximum residual level (MRL). The dynamic ranges were both from each of their LODs to 100 μg/mL. The 50% inhibition concentrations (IC50) in TBS and skim milk were 199.66 ng/mL and 360.81 ng/mL, respectively. We also demonstrated the good specificity of this platform by comparing detection results between pure Gentamycin solution and a mixture solution of 6 different antibiotics including Gentamycin in skim milk. The entire assay with 60 samples was conducted within 2h. In sum, this novel biosensing platform not only fulfilled most benefits of magnetic bead-based assays, but also was inexpensive and convenient by replacing the magnetic separation with filtration plate separation. PMID:23728198

  2. A Novel 96well-formatted Micro-gap Plate Enabling Drug Response Profiling on Primary Tumour Samples

    NASA Astrophysics Data System (ADS)

    Ma, Wei-Yuan; Hsiung, Lo-Chang; Wang, Chen-Ho; Chiang, Chi-Ling; Lin, Ching-Hung; Huang, Chiun-Sheng; Wo, Andrew M.

    2015-04-01

    Drug-based treatments are the most widely used interventions for cancer management. Personalized drug response profiling remains inherently challenging with low cell count harvested from tumour sample. We present a 96well-formatted microfluidic plate with built-in micro-gap that preserves up to 99.2% of cells during multiple assay/wash operation and only 9,000 cells needed for a single reagent test (i.e. 1,000 cells per test spot x 3 selected concentration x triplication), enabling drug screening and compatibility with conventional automated workstations. Results with MCF7 and MDA-MB-231 cell lines showed that no statistical significance was found in dose-response between the device and conventional 96-well plate control. Primary tumour samples from breast cancer patients tested in the device also showed good IC50 prediction. With drug screening of primary cancer cells must consider a wide range of scenarios, e.g. suspended/attached cell types and rare/abundant cell availability, the device enables high throughput screening even for suspended cells with low cell count since the signature microfluidic cell-trapping feature ensures cell preservation in a multiple solution exchange protocol.

  3. Development of a fluorimetric multispecies 96-well micro-plate growth test for screening metal toxicity to phytoplankton

    SciTech Connect

    Peterson, H.G.; Ruecker, N.J.; Cantin, I.A.; Nyholm, N.; Dal-Jensen, S.

    1995-12-31

    The rapid and cost-effective screening of industrial waste is an ideal approach to regulations that offer true protection of aquatic habitats. For these tests to be ecologically important protection of large groups of organisms is also essential. This can best be done by testing batteries of species. Photosynthetic organisms compose 99.9% of habitats as well as providing food for higher trophic levels. A test was developed that can accommodate the testing of most phytoplanktonic species irrespective of morphology (unicellular, multicellular, colonial, filamentous). Forty eight to 72 h growth tests were carried out with green algae, diatoms, and cyanobacteria. The algae were incubated with different levels of toxicants in 96-well microplates which were read in a 96-well fluorometric plate reader. Phytoplankton emitting low levels of fluorescence can be incubated with DCMU, which can increase the fluorescent signal 2 to 4 times. The data from the plate reader is transferred to a computer spreadsheet and inhibition levels are automatically calculated. Eleven metal mining wastes from across Canada were tested against this method using the following phytoplanktonic species: Selenastrum, Nannochloris (green algae), Nitzschia (diatom), Microcystis, and Pseudoanabaena (cyanobacteria). These wastes were also screened against Microtox. All wastes were highly toxic to the tested phytoplankton, but only 4 were toxic to Microtox{trademark}.

  4. Scalable 96-well Plate Based iPSC Culture and Production Using a Robotic Liquid Handling System

    PubMed Central

    Conway, Michael K.; Gerger, Michael J.; Balay, Erin E.; O'Connell, Rachel; Hanson, Seth; Daily, Neil J.; Wakatsuki, Tetsuro

    2015-01-01

    Continued advancement in pluripotent stem cell culture is closing the gap between bench and bedside for using these cells in regenerative medicine, drug discovery and safety testing. In order to produce stem cell derived biopharmaceutics and cells for tissue engineering and transplantation, a cost-effective cell-manufacturing technology is essential. Maintenance of pluripotency and stable performance of cells in downstream applications (e.g., cell differentiation) over time is paramount to large scale cell production. Yet that can be difficult to achieve especially if cells are cultured manually where the operator can introduce significant variability as well as be prohibitively expensive to scale-up. To enable high-throughput, large-scale stem cell production and remove operator influence novel stem cell culture protocols using a bench-top multi-channel liquid handling robot were developed that require minimal technician involvement or experience. With these protocols human induced pluripotent stem cells (iPSCs) were cultured in feeder-free conditions directly from a frozen stock and maintained in 96-well plates. Depending on cell line and desired scale-up rate, the operator can easily determine when to passage based on a series of images showing the optimal colony densities for splitting. Then the necessary reagents are prepared to perform a colony split to new plates without a centrifugation step. After 20 passages (~3 months), two iPSC lines maintained stable karyotypes, expressed stem cell markers, and differentiated into cardiomyocytes with high efficiency. The system can perform subsequent high-throughput screening of new differentiation protocols or genetic manipulation designed for 96-well plates. This technology will reduce the labor and technical burden to produce large numbers of identical stem cells for a myriad of applications. PMID:26068617

  5. Scalable 96-well Plate Based iPSC Culture and Production Using a Robotic Liquid Handling System.

    PubMed

    Conway, Michael K; Gerger, Michael J; Balay, Erin E; O'Connell, Rachel; Hanson, Seth; Daily, Neil J; Wakatsuki, Tetsuro

    2015-01-01

    Continued advancement in pluripotent stem cell culture is closing the gap between bench and bedside for using these cells in regenerative medicine, drug discovery and safety testing. In order to produce stem cell derived biopharmaceutics and cells for tissue engineering and transplantation, a cost-effective cell-manufacturing technology is essential. Maintenance of pluripotency and stable performance of cells in downstream applications (e.g., cell differentiation) over time is paramount to large scale cell production. Yet that can be difficult to achieve especially if cells are cultured manually where the operator can introduce significant variability as well as be prohibitively expensive to scale-up. To enable high-throughput, large-scale stem cell production and remove operator influence novel stem cell culture protocols using a bench-top multi-channel liquid handling robot were developed that require minimal technician involvement or experience. With these protocols human induced pluripotent stem cells (iPSCs) were cultured in feeder-free conditions directly from a frozen stock and maintained in 96-well plates. Depending on cell line and desired scale-up rate, the operator can easily determine when to passage based on a series of images showing the optimal colony densities for splitting. Then the necessary reagents are prepared to perform a colony split to new plates without a centrifugation step. After 20 passages (~3 months), two iPSC lines maintained stable karyotypes, expressed stem cell markers, and differentiated into cardiomyocytes with high efficiency. The system can perform subsequent high-throughput screening of new differentiation protocols or genetic manipulation designed for 96-well plates. This technology will reduce the labor and technical burden to produce large numbers of identical stem cells for a myriad of applications. PMID:26068617

  6. 96-Well Plate Colorimetric Assay for K(sub i) Determination of (plusmn)-2-Benzylsuccinic Acid, an Inhibitor of Carboxypeptidase A

    ERIC Educational Resources Information Center

    Wentland, Mark P.; Raza, Shaan; Yingtong Gao

    2004-01-01

    An appropriate assay to determine the inhibition potency of carboxypeptidase A (CPA) in 96-well format to illustrate how high throughput screening is used in modern drug discovery to identify bioactive molecules is developed. Efforts in developing a colorimetric 96-well plate assay for determination of the K(sub i) for inhibition of CPA by…

  7. Facile preparation of a photoactivatable surface on a 96-well plate: a versatile and multiplex cell migration assay platform.

    PubMed

    Kamimura, Masao; Scheideler, Olivia; Shimizu, Yoshihisa; Yamamoto, Shota; Yamaguchi, Kazuo; Nakanishi, Jun

    2015-06-01

    Cell migration is an essential cellular activity in various physiological and pathological processes, such as wound healing and cancer metastasis. Therefore, in vitro cell migration assays are important not only for fundamental biological studies but also for evaluating potential drugs that control cell migration activity in medical applications. In this regard, robust control over cell migrating microenvironments is critical for reliable and quantitative analysis as cell migration is highly dependent upon the microenvironments. Here, we developed a facile method for making a commercial glass-bottom 96-well plate photoactivatable for cell adhesion, aiming to develop a versatile and multiplex cell migration assay platform. Cationic poly-d-lysine was adsorbed to the anionic glass surface via electrostatic interactions and, subsequently, functionalized with poly(ethylene glycol) (PEG) bearing a photocleavable reactive group. The initial PEGylated surface is non-cell-adhesive. However, upon near-ultraviolet (UV) irradiation, the photorelease of PEG switches the surface from non-biofouling to cell-adhesive. With this platform, we assayed cell migration in the following procedure: (1) create cell-attaching regions of precise geometries by controlled photoirradiation, (2) seed cells to allow them to attach selectively to the irradiated regions, (3) expose UV light to the remaining PEGylated regions to extend the cell-adhesive area, (4) analyse cell migration using microscopy. Surface modification of the glass surface was characterized by ζ-potential and contact angle measurements. The PEGylated surface showed cell-resistivity and became cell-adhesive upon releasing PEG by near-UV irradiation. The method was applied for parallelly evaluating the effect of model drugs on the migration of epithelial MDCK cells in the multiplexed platform. The dose-response relationship for cytochalasin D treatment on cell migration behavior was successfully evaluated with high

  8. Enhanced binding of capsular polysaccharides of Cryptococcus neoformans to polystyrene microtitration plates for enzyme-linked immunosorbent assay.

    PubMed

    Cherniak, R; Cheeseman, M M; Reyes, G H; Reiss, E; Todaro, F

    1988-01-01

    A sensitive enzyme-linked immunosorbent assay (ELISA) to measure antibodies against capsular polysaccharide was developed, based on the enhanced binding of polysaccharide to polystyrene microtitration plates. The wells of the microtitration plate were primed with an adipic acid dihydrazide derivative of bovine serum albumin (AH-BSA) (100 micrograms/mL, 0.01 M NaPO4-0.14 M NaCl, pH 7.2 (PBS]. Capsular polysaccharide, the glucuronoxylomannan of Cryptococcus neoformans serotype A, was oxidized with NaIO4 for 5 min; the reaction was then quenched with ethylene glycol. The partially oxidized polysaccharide was dialyzed vs. PBS, and its concentration was adjusted to 50 micrograms/mL with PBS. This solution (100 microL/well) was covalently bound to the AH-BSA primed microtitration plates through formation of a Schiff base between the hydrazide group on the AH-BSA and the aldehyde groups on the polysaccharide. Antimouse IgG-alkaline phosphatase conjugate was used in an indirect ELISA to measure captured murine monoclonal antibodies directed against glucuronoxylomannan. Mean absorbances, after 15 min, were 0.13 in negative control wells, and greater than 0.7 in test wells. No intermediate steps were required to block nonspecific binding of antibody. PMID:3064947

  9. Immobilization of saccharides and peptides on 96-well microtiter plates coated with methyl vinyl ether-maleic anhydride copolymer.

    PubMed

    Satoh, A; Kojima, K; Koyama, T; Ogawa, H; Matsumoto, I

    1998-06-15

    We have previously reported a method to immobilize protein ligands on microtiter plates coated with methyl vinyl ether-maleic anhydride copolymer (MMAC) [Isosaki, K., et al. (1992) J. Chromatogr. 597, 123-128]. In this study, we improved the MMAC method to efficiently immobilize not only small ligands such as peptides and oligosaccharides, which could not be efficiently immobilized previously, but also heparin via its reducing end. Amino and hydrazino groups were introduced to MMAC-coated microtiter plate wells by coupling to acid anhydride groups of MMAC with 1,6-hexamethylenediamine and adipic acid dihydrazide, respectively. The amino groups introduced were allowed to react with peptides by use of divalent cross-linkers. Hydrazino groups were allowed to react with formyl groups of saccharides by reductive amination. Peptides and oligosaccharides were immobilized in a dose-dependent manner by these methods. In the case of the angiotensin peptide thus immobilized, the detection limit by monoclonal antibodies was as low as 0.1-1 fmol peptide per well. Application of 20-200 nmol oligosaccharides to the well was sufficient to immobilize and subsequently detect lectins. Furthermore, heparin immobilized on the hydrazinocoated wells was successfully used for the binding assay of annexin IV. PMID:9648659

  10. Collection, storage, and filtration of in vivo study samples using 96-well filter plates to facilitate automated sample preparation and LC/MS/MS analysis.

    PubMed

    Berna, M; Murphy, A T; Wilken, B; Ackermann, B

    2002-03-01

    The benefits of high-throughput bioanalysis within the pharmaceutical industry are well established. One of the most significant bottlenecks in bioanalysis is transferring in vivo-generated study samples from their collection tubes during sample preparation and extraction. In most cases, the plasma samples must be stored frozen prior to analysis, and the freeze/thaw (F/T) process introduces thrombin clots that are capable of plugging pipets and automated liquid-transfer systems. A new approach to dealing with this problem involves the use of Ansys Captiva 96-well 20-microm polypropylene filter plates to collect, store frozen, and filter plasma samples prior to bioanalysis. The samples are collected from the test subjects, and the corresponding plasma samples are placed directly into the wells of the filter plate. Two Duoseal (patent pending) covers are used to seal the top and bottom of the plate, and the plate is stored at down to -70 degrees C. Prior to sample analysis, the seals are removed and the plate is placed in a 96-well SPE manifold. As the plasma thaws, it passes (by gravity or mild vacuum) through the polypropylene filter into a 96-well collection plate. A multichannel pipet or automated liquid-transfer system is used to transfer sample aliquots without fear of plugging. A significant advantage of this approach is that, unlike other methods, issues related to incomplete pipetting are virtually eliminated. The entire process is rapid since thawing and filtering take place simultaneously, and if a second F/T cycle is required for reanalysis, it is not necessary to refilter the samples (additional clotting was not observed after three F/T cycles). This technique was tested using monkey, rat, and dog plasma and sodium heparin and EDTA anticoagulants. To assess the possibility of nonspecific binding to the polypropylene filter, a variety of drug candidates from diverse drug classes were studied. Validation data generated for two Lilly compounds from distinct

  11. Quantum dot immunoassays in renewable surface column and 96-well plate formats for the fluorescence detection of Botulinum neurotoxin using high-affinity antibodies

    PubMed Central

    Grate, Jay W.; Tyler, Abby; Ozanich, Richard M.; Miller, Keith D.; Lou, Jianlong; Marks, James D.; Bruckner-Lea, Cynthia J.

    2009-01-01

    A fluorescence sandwich immunoassay using high affinity antibodies and quantum dot (QD) reporters has been developed for detection of botulinum neurotoxin serotype A (BoNT/A) using a nontoxic recombinant fragment of the holotoxin (BoNT/A-HC-fragment) as a structurally valid simulant for the full toxin molecule. The antibodies used, AR4 and RAZ1, bind to nonoverlapping epitopes present on both the full toxin and on the recombinant fragment. In one format, the immunoassay is carried out in a 96-well plate with detection in a standard plate reader using AR4 as the capture antibody and QD-coupled RAZ1 as the reporter. Detection to 31 pM with a total incubation time of 3 hours was demonstrated. In a second format, the AR4 capture antibody was coupled to Sepharose beads, and the reactions were carried out in microcentrifuge tubes with an incubation time of 1 hour. The beads were subsequently captured and concentrated in a rotating rod “renewable surface” flow cell equipped with a fiber optic system for fluorescence measurements. In PBS buffer, the BoNT/A-HC-fragment was detected to concentrations as low as 5 pM using the fluidic measurement approach. PMID:19643593

  12. Quantum dot immunoassays in renewable surface column and 96-well plate formats for the fluorescence detection of Botulinum neurotoxin using high-affinity antibodies

    SciTech Connect

    Warner, Marvin G.; Grate, Jay W.; Tyler, Abby J.; Ozanich, Richard M.; Miller, Keith D.; Lou, Jianlong; Marks, James D.; Bruckner-Lea, Cindy J.

    2009-09-01

    A fluorescence sandwich immunoassay using high affinity antibodies and quantum dot (QD) reporters has been developed for detection of botulinum toxin serotype A (BoNT/A). For the development of the assay, a nontoxic recombinant fragment of the holotoxin (BoNT/A-HC-fragment) has been used as a structurally valid simulant for the full toxin molecule. The antibodies used, AR4 and RAZ1, bind to nonoverlapping epitopes present on both the full toxin and on the recombinant fragment. In one format, the immunoassay is carried out in a 96-well plate with detection in a standard plate reader. Detection down to 31 pM of the BoNT/Hc-fragment was demonstrated with a total incubation time of 3 hours, using AR4 as the capture antibody and QD-coupled RAZ1 as the reporter. In a second format, the AR4 capture antibody was coupled to Sepharose beads, and the immunochemical reactions were carried out in microcentrifuge tubes with an incubation time of 1 hour. These beads were subsequently captured and concentrated in a rotating rod “renewable surface” flow cell as part of a sequential injection fluidic system. This flow cell was equipped with a fiber optic system for fluorescence measurements. In PBS buffer solution matrix, the BoNT/A-HC-fragment was detected to concentrations as low as 5 pM using the fluidic measurement approach.

  13. Identification of photosynthesis inhibitors of pelagic marine algae using 96-well plate microfractionation for enhanced throughput in effect-directed analysis.

    PubMed

    Booij, Petra; Vethaak, A Dick; Leonards, Pim E G; Sjollema, Sascha B; Kool, Jeroen; de Voogt, Pim; Lamoree, Marja H

    2014-07-15

    Because of large-scale production and use of an increasing diversity of chemicals in modern society, estuarine and coastal waters may be contaminated with numerous substances. Some of these compounds have the potential to affect microalgae at the base of the pelagic food chain. Therefore, we identified the main chemical stressors that negatively affect the effective photosystem II efficiency (ϕPSII) in marine microalgae of the Dutch estuarine and coastal waters. An enhanced effect-directed analysis (EDA) was carried out by combining reversed-phase ultra performance liquid chromatography fractionation of extracts from passive samplers, followed by effect assessment using the pulse amplitude modulation fluorometry assay and chemical analysis of biologically active fractions using high-resolution mass spectrometry. This study focuses on a novel microfractionation technique using 96-well plates to enhance throughput in EDA, structure elucidation, and the analytical and effect confirmation of the compounds that are identified. Although there are numerous unknown compounds present in estuarine and coastal waters, our EDA study shows that atrazine, diuron, irgarol, isoproturon, terbutryn, and terbutylazine are the main contributors to the observed effect on the ϕPSII of marine microalgae. PMID:24926900

  14. High throughput adjustable 96-well plate assay for androgen receptor binding: a practical approach for EDC screening using the chimpanzee AR.

    PubMed

    Hartig, P C; Cardon, M C; Blystone, C R; Gray, L E; Wilson, V S

    2008-09-26

    The issue as to whether natural and man-made chemicals interfere with endocrine function has raised concerns. This interference could be biologically significant even at very low doses if the chemicals interact deleteriously with hormone receptors at low concentrations. Therefore, the United States Environmental Protection Agency (USEPA) Office of Coordination and Policy (OSCP) requested that a nonhuman mammalian androgen receptor binding assay be developed for possible use in their Endocrine Disruptor Screening Program (EDSP). Ideally, this assay would be high throughput, not use animals as a source of receptor protein, easily deployed throughout the scientific community, utilize reagents available to both the public and private sector, and have the potential for future automation. We developed a highly modified 96-well plate assay which meets these criteria. It employs a baculovirus expressed recombinant primate androgen receptor which is publically available and exploits the unique ability of some mammalian androgen receptors to remain biologically active after guanidine hydrochloride (GdnHCl) solubilization. This GdnHCl treated receptor remains soluble and requires no additional purification prior to use. We provide a very detailed description of the assay protocol itself, and similarly detailed method for producing and solubilizing the receptor. PMID:18691642

  15. Development of a microtitre plate-based assay for lipid-linked glycosyltransferase products using the mycobacterial cell wall rhamnosyltransferase WbbL.

    PubMed

    Grzegorzewicz, Anna E; Ma, Yufang; Jones, Victoria; Crick, Dean; Liav, Avraham; McNeil, Michael R

    2008-12-01

    In Mycobacterium tuberculosis a rhamnosyltransferase (WbbL) catalyses the transfer of an alpha-L-Rhap residue from dTDP-L-rhamnose (dTDP-Rha) to decaprenyldiphosphoryl-alpha-D-N-acetylglucosamine (GlcNAc-P-P-DP) to form alpha-L-Rhap-(1-->3)-alpha-D-GlcNAc-P-P-DP, which is then further elongated with Galf and Araf units, and finally mycolylated and attached to the peptidoglycan. This enzyme is essential for M. tuberculosis viability and at the same time absent in eukaryotic cells, and is therefore a good target for the development of new antituberculosis therapeutics. Here, we report a microtitre plate-based method for the assay of this enzyme using a crude membrane preparation from an Escherichia coli strain overexpressing wbbL as an enzyme source and the natural acceptor substrate GlcNAc-P-P-DP. Initial characterization of the enzyme included unequivocal identification of the product Rha-GlcNAc-P-P-DP by liquid chromatography (LC)-MS, and the facts that WbbL shows an absolute requirement for divalent cations and that its activity is stimulated by beta-mercaptoethanol. Its pH optimum and basic kinetic parameters were also determined, and the kinetic analysis showed that WbbL uses a ternary complex mechanism. The microtitre plate-based assay for this enzyme was developed by taking advantage of the lipophilic nature of the product. This assay should be readily transferable to other glycosyltransferases which use lipid-based acceptors and aid greatly in obtaining inhibitors of such glycosyltransferases for new drug development. PMID:19047740

  16. A novel colorimetric assay of β-D-glucans in basidiomycete strains by alcian blue dye in a 96-well microtiter plate.

    PubMed

    C Semedo, Magda; Karmali, Amin; Fonseca, Luís

    2015-01-01

    Basidiomycete strains synthesize several types of β-d-glucans, which play a major role in the medicinal properties of mushrooms. Therefore, the specific quantification of these β-d-glucans in mushroom strains is of great biochemical importance. Because published assay methods for these β-d-glucans present some disadvantages, a novel colorimetric assay method for β-d-glucan with alcian blue dye was developed. The complex formation was detected by following the decrease in absorbance in the range of 620 nm and by hypsochromic shift from 620 to 606 nm (∼14 nm) in UV-Vis spectrophotometer. Analysis of variance was used for optimization of the slope of the calibration curve by using the assay mixture containing 0.017% (w/v) alcian blue in 2% (v/v) acetic acid at pH 3.0. The high-throughput colorimetric assay method on microtiter plates was used for quantification of β-d-glucans in the range of 0-0.8 μg, with a slope of 44.15 × 10(-2) and a limit of detection of 0.017 μg/well. Recovery experiments were carried out by using a sample of Hericium erinaceus, which exhibited a recovery of 95.8% for β-1,3-d-glucan. The present assay method exhibited a 10-fold higher sensitivity and a 59-fold lower limit of detection compared with the published method with congo red. β-d-glucans of several mushrooms strains were isolated from fruiting bodies and mycelia, and they were quantified by this assay method. This assay method is fast, specific, simple, and it can be used to quantify β-d-glucans from other biological sources. PMID:26317582

  17. Development and application of a high-throughput sample cleanup process based on 96-well plate for simultaneous determination of 16 steroids in biological matrices using liquid chromatography-triple quadrupole mass spectrometry.

    PubMed

    Luo, Guanzhong; Li, Youxin; Bao, James J

    2016-02-01

    A novel high-throughput sample pretreatment system was developed by the integration of protein precipitation (PP), phospholipid removal (PPR), and hollow fiber liquid-phase microextraction (HF-LPME) into two simple 96-well plates and a matching 96-grid lid. With this system, 16 steroids were separated from biological matrices of plasma, milk, and urine and analyzed by liquid chromatography-triple quadrupole mass spectrometry. In the tandem sample cleanup process, the prepositive PP and PPR step preliminarily removed some of the interferences from the biological matrices. The following HF-LPME step kept the residual interference out of the hollow fiber and enriched the steroids in the hollow fiber to achieve high sensitivity. By a series of method optimizations, acetonitrile was chosen as the crash solvent for PP and PPR. A mixture of octanol and toluene (1:1 v/v) was used as the acceptor phase for HF-LPME. The extraction was conducted at 80 rpm for 50 min in a donor phase containing 1 mL 20% sodium chloride at 25 °C. Under these conditions, the limits of detection for the 16 steroids were 3.6-300.0 pg(.)mL(-1) in plasma, 3.0-270.0 pg·mL(-1) in milk, and 2.2-210.0 pg(.)mL(-1) in urine. The recoveries of the 16 steroids were 81.9-97.9% in plasma (relative standard deviation 1.0-8.0%), 80.6-97.7% in milk (relative standard deviation 0.8-5.4%), and 87.3-98.7% in urine (relative standard deviation 1.0-4.9%). Further, the integrated 96-well platform of PP, PPR, and HF-LPME enabled us to run this assay in an automatic and high-throughput fashion. The reliability of the method was further corroborated by evaluation of its applicability in plasma and urine samples from volunteers and fresh bovine milk from local dairy enterprises. PMID:26738495

  18. A protein-protein binding assay using coated microtitre plates: increased throughput, reproducibility and speed compared to bead-based assays.

    PubMed

    Craig, Tim J; Ciufo, Leonora F; Morgan, Alan

    2004-07-30

    Protein-protein interactions, and the factors affecting them, are of fundamental importance to all biological systems. Surface plasmon resonance (SPR) and isothermal titration calorimetry (ITR) are powerful methods for assaying such interactions, but are expensive to implement. In contrast, bead-based pull-down assays using affinity tags such as glutathione-S-transferase (GST), require no specialist equipment. As a result, such assays are the most popular method for analysing protein-protein interactions, despite being time-consuming and prone to variability. In respect of these problems, we have modified this form of binding assay, using glutathione-coated 96-well plates rather than glutathione-Sepharose beads to bind the primary bait protein. Quantitation of bound protein utilises ELISA for purified proteins and scintillation counting for in vitro translated proteins, rather than the SDS-PAGE-based detection methods used in traditional bead-based assays. These modifications result in an approximately 10-fold increase in the number of samples that can be assayed daily, and allow results to be obtained within hours as opposed to days. We validate the modified assay by analysing the equilibrium binding of Munc18 and syntaxin, and also demonstrate that association and dissociation kinetics may be measured using this approach. The method we describe is generally applicable to any protein-protein interaction assay based on affinity tags and is amenable to automation, and so should benefit a wide range of biochemical research. PMID:15236910

  19. [Proposals of the working group "Antibiotic resistance" for the configuration of microtitre plates to be used in routine antimicrobial susceptibility testing of bacterial pathogens from infections of large food-producing animals and mastitis cases].

    PubMed

    Luhofer, Gabriele; Böttner, Alexander; Hafez, H Mohamed; Kaske, Martin; Kehrenberg, Corinna; Kietzmann, Manfred; Klarmann, Dieter; Klein, Günter; Krabisch, Peter; Kühn, Tilman; Richter, Angelika; Sigge, Claudia; Traeder, Wolfgang; Waldmann, Karl-Heinz; Wallmann, Jürgen; Werckenthin, Christiane; Schwarz, Stefan

    2004-01-01

    Two layouts for microtitre plates, which should serve for in-vitro susceptibility testing in routine diagnostics, have been set up by the working group "Antibiotic resistance" of the German Society for Veterinary Medicine. One of these layouts was designed for the testing of bacteria from cases of mastitis and the other for bacteria from infections in large food-producing animals. The choice of the antimicrobial agents and their concentrations to be included in these layouts were based on (1) the bacteria frequently associated with the respective diseases/animals, (2) the antimicrobial agents licensed for therapeutic use in these diseases/animals, (3) the currently available breakpoints, and (4) cross-resistances between the antimicrobial agerts so far known to occur in the respective bacteria. PMID:15298050

  20. Location dependent biases in automatic 96-well microplate readers.

    PubMed

    Harrison, R O; Hammock, B D

    1988-01-01

    Procedures performed in 96-well microplates and quantitated by automatic readers assume instruments to be precise, accurate, and free of well location dependent bias. Instrument specifications generally focus on precision and accuracy without specifically addressing biases which are dependent on well location. These biases appear to be meniscus dependent and can be demonstrated in varying degrees in automatic readers of many designs by using a reverse plate wet test, which compares repeated readings of a dye loaded plate in normal and reversed positions. This test analyzes differences between readings and is, therefore, independent of pipetting error or other experimental variables such as protein binding or immunoassay variability. Different plates increased or decreased the magnitude of observed errors but did not themselves cause the errors measured by the reverse plate wet test. Error patterns were consistent for each reader and varied widely among the 16 instruments tested. Only 4 of 16 instruments passed an existing manufacturer's specification for precision, and only one of the 16 readers tested passed a similar specification for accuracy. The severest location dependent bias was found in an instrument which exhibited excellent repeatability and consistently passed its built-in diagnostic tests. One reader with significant bias was returned to the manufacturer for routine service and calibration, but it was not demonstrably improved. The reverse plate wet test is an extremely useful diagnostic tool for quality control at all stages of instrument manufacture and use. PMID:3069835

  1. 21 CFR 862.2680 - Microtitrator for clinical use.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Laboratory Instruments § 862.2680 Microtitrator for clinical use. (a) Identification. A microtitrator for clinical use is... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Microtitrator for clinical use. 862.2680...

  2. 21 CFR 862.2680 - Microtitrator for clinical use.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Laboratory Instruments § 862.2680 Microtitrator for clinical use. (a) Identification. A microtitrator for clinical use is... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Microtitrator for clinical use. 862.2680...

  3. 21 CFR 862.2680 - Microtitrator for clinical use.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Laboratory Instruments § 862.2680 Microtitrator for clinical use. (a) Identification. A microtitrator for clinical use is... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Microtitrator for clinical use. 862.2680...

  4. A microassay for measuring glycogen in 96-well-cultured cells.

    PubMed

    Gómez-Lechón, M J; Ponsoda, X; Castell, J V

    1996-05-01

    This study describes a rapid, sensitive, and automated spectrophotometric enzymatic microassay that measures the intracellular glycogen of primary cultured hepatocytes and other cultured cells in 96-well plates and can be adapted for other samples that are transferred to these plates. The procedure involves in situ disruption of cells, followed by hydrolysis of glycogen into glucosyl units by fungal glucoamylase (exo-1.4-alpha-glucosidase, EC 3.2.1.3), and glucose determination with the glucose oxidase colorimetric method. The color intensity can be measured in conventional ELISA readers, and the data can be fed to an on-line computer for rapid processing. The advantages of this method are its simplicity and automation, the reduction in sample handling, and the small number of cells required compared to other conventional methods. PMID:8660508

  5. Automation of cell-based drug absorption assays in 96-well format using permeable support systems.

    PubMed

    Larson, Brad; Banks, Peter; Sherman, Hilary; Rothenberg, Mark

    2012-06-01

    Cell-based drug absorption assays, such as Caco-2 and MDCK-MDR1, are an essential component of lead compound ADME/Tox testing. The permeability and transport data they provide can determine whether a compound continues in the drug discovery process. Current methods typically incorporate 24-well microplates and are performed manually. Yet the need to generate absorption data earlier in the drug discovery process, on an increasing number of compounds, is driving the use of higher density plates. A simple, more efficient process that incorporates 96-well permeable supports and proper instrumentation in an automated process provides more reproducible data compared to manual methods. Here we demonstrate the ability to perform drug permeability and transport assays using Caco-2 or MDCKII-MDR1 cells. The assay procedure was automated in a 96-well format, including cell seeding, media and buffer exchanges, compound dispense, and sample removal using simple robotic instrumentation. Cell monolayer integrity was confirmed via transepithelial electrical resistance and Lucifer yellow measurements. Proper cell function was validated by analyzing apical-to-basolateral and basolateral-to-apical movement of rhodamine 123, a known P-glycoprotein substrate. Apparent permeability and efflux data demonstrate how the automated procedure provides a less variable method than manual processing, and delivers a more accurate assessment of a compound's absorption characteristics. PMID:22357561

  6. Establishment and validation of a method for multi-dose irradiation of cells in 96-well microplates

    SciTech Connect

    Abatzoglou, Ioannis; Zois, Christos E.; Pouliliou, Stamatia

    2013-02-15

    Highlights: ► We established a method for multi-dose irradiation of cell cultures within a 96-well plate. ► Equations to adjust to preferable dose levels are produced and provided. ► Up to eight different dose levels can be tested in one microplate. ► This method results in fast and reliable estimation of radiation dose–response curves. -- Abstract: Microplates are useful tools in chemistry, biotechnology and molecular biology. In radiobiology research, these can be also applied to assess the effect of a certain radiation dose delivered to the whole microplate, to test radio-sensitivity, radio-sensitization or radio-protection. Whether different radiation doses can be accurately applied to a single 96-well plate to further facilitate and accelerated research by one hand and spare funds on the other, is a question dealt in the current paper. Following repeated ion-chamber, TLD and radiotherapy planning dosimetry we established a method for multi-dose irradiation of cell cultures within a 96-well plate, which allows an accurate delivery of desired doses in sequential columns of the microplate. Up to eight different dose levels can be tested in one microplate. This method results in fast and reliable estimation of radiation dose–response curves.

  7. High throughput preparation of fly genomic DNA in 96-well format using a paint-shaker.

    PubMed

    Lang, Michael; Nagy, Olga; Lang, Claus; Orgogozo, Virginie

    2015-01-01

    Sample homogenization is an essential step for genomic DNA extraction, with multiple downstream applications in Molecular Biology. Genotyping hundreds or thousands of samples requires an automation of this homogenization step, and high throughput homogenizer equipment currently costs 7000 euros or more. We present an apparatus for homogenization of individual Drosophila adult flies in 96-well micro-titer dishes, which was built from a small portable paint-shaker (F5 portable paint-shaker, Ushake). Single flies are disrupted in each well that contains extraction buffer and a 4-mm metal ball. Our apparatus can hold up to five 96-well micro-titer plates. Construction of the homogenizer apparatus takes about 3-4 days, and all equipment can be obtained from a home improvement store. The total material cost is approximately 700 euros including the paint-shaker. We tested the performance of our apparatus using the ZR-96 Quick-gDNA™ kit (Zymo Research) homogenization buffer and achieved nearly complete tissue homogenization after 15 minutes of shaking. PCR tests did not detect any cross contamination between samples of neighboring wells. We obtained on average 138 ng of genomic DNA per fly, and DNA quality was adequate for standard PCR applications. In principle, our tissue homogenizer can be used for isolation of DNA suitable for library production and high throughput genotyping by Multiplexed Shotgun Genotyping (MSG), as well as RNA isolation from single flies. The sample adapter can also hold and shake other items, such as centrifuge tubes (15-50 mL) or small bottles. PMID:26818699

  8. High throughput preparation of fly genomic DNA in 96-well format using a paint-shaker

    PubMed Central

    Lang, Michael; Nagy, Olga; Lang, Claus; Orgogozo, Virginie

    2015-01-01

    Sample homogenization is an essential step for genomic DNA extraction, with multiple downstream applications in Molecular Biology. Genotyping hundreds or thousands of samples requires an automation of this homogenization step, and high throughput homogenizer equipment currently costs 7000 euros or more. We present an apparatus for homogenization of individual Drosophila adult flies in 96-well micro-titer dishes, which was built from a small portable paint-shaker (F5 portable paint-shaker, Ushake). Single flies are disrupted in each well that contains extraction buffer and a 4-mm metal ball. Our apparatus can hold up to five 96-well micro-titer plates. Construction of the homogenizer apparatus takes about 3–4 days, and all equipment can be obtained from a home improvement store. The total material cost is approximately 700 euros including the paint-shaker. We tested the performance of our apparatus using the ZR-96 Quick-gDNA™ kit (Zymo Research) homogenization buffer and achieved nearly complete tissue homogenization after 15 minutes of shaking. PCR tests did not detect any cross contamination between samples of neighboring wells. We obtained on average 138 ng of genomic DNA per fly, and DNA quality was adequate for standard PCR applications. In principle, our tissue homogenizer can be used for isolation of DNA suitable for library production and high throughput genotyping by Multiplexed Shotgun Genotyping (MSG), as well as RNA isolation from single flies. The sample adapter can also hold and shake other items, such as centrifuge tubes (15–50 mL) or small bottles. PMID:26818699

  9. Application of the resazurin microtitre assay for detection of multidrug resistance in Mycobacterium tuberculosis in Algiers.

    PubMed

    Nateche, Farida; Martin, Anandi; Baraka, Saliha; Palomino, Juan Carlos; Khaled, Safia; Portaels, Françoise

    2006-07-01

    This study assessed the performance of a rapid, low-cost, colorimetric method, the resazurin microtitre assay (REMA) plate method, for the detection of resistance to isoniazid and rifampicin in 136 clinical isolates of Mycobacterium tuberculosis from two hospitals in Algiers. MICs were determined and the results were compared with those obtained with the conventional proportion method on Löwenstein-Jensen medium. Excellent results were obtained for the REMA plate method, with a sensitivity of 100 % for both isoniazid and rifampicin and a specificity of 98.3 and 99.2 %, respectively. The REMA plate method appears to be a reliable method for the rapid determination of multidrug-resistant tuberculosis and is a good alternative for use in resource-limited countries such as Algeria. PMID:16772411

  10. 21 CFR 862.2680 - Microtitrator for clinical use.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Microtitrator for clinical use. 862.2680 Section 862.2680 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical...

  11. Determining cereal starch amylose content using a dual wavelength iodine binding 96 well plate assay

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Cereal starch amylose/amylopectin (AM/AP) ratios are critical in functional properties for food and industrial applications. Conventional determination of AM/AP of cereal starches are very time consuming and labor intensive making it very difficult to screen large sample sets. Studying these large...

  12. Development of a 96-well plate iodine binding assay for amylose content determination

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Cereal starch amylose/amylopectin (AM/AP) ratios are critical in functional properties for food and industrial applications. Conventional methods for the determination of AM/AP of cereal starches are very time consuming and labor intensive making it very difficult to screen large sample sets. Stud...

  13. Folate content in fresh-cut vegetable packed products by 96-well microtiter plate microbiological assay.

    PubMed

    Fajardo, Violeta; Alonso-Aperte, Elena; Varela-Moreiras, Gregorio

    2015-02-15

    Ready-to-eat foods have nowadays become a significant portion of the diet. Accordingly, nutritional composition of these food categories should be well-known, in particular its folate content. However, there is a broad lack of folate data in food composition tables and databases. A total of 21 fresh-cut vegetable and fruit packed products were analysed for total folate (TF) content using a validated method that relies on the folate-dependent growth of chloramphenicol-resistant Lactobacillus casei subspecies rhamnosus (NCIMB 10463). Mean TF content ranged from 10.0 to 140.9μg/100g for the different matrices on a fresh weight basis. Higher TF quantity, 140.9-70.1μg/100g, was found in spinach, rocket, watercress, chard and broccoli. Significant differences were observed between available data for fresh vegetables and fruits from food composition tables or databases and the analysed results for fresh-cut packed products. Supplied data support the potential of folate-rich fresh-cut ready-to-eat vegetables to increase folate intake significantly. PMID:25236228

  14. HIGHLY SENSITIVE ASSAY FOR ANTICHOLINESTERASE COMPOUNDS USING 96 WELL PLATE FORMAT

    EPA Science Inventory

    One of the approaches for reducing uncertainties in the assessment of human exposure is to better characterize concentrations of hazardous compounds that may be present in our immediate environment. A significant limitation to this approach, however, is that sampling and labora...

  15. Protocol: high throughput silica-based purification of RNA from Arabidopsis seedlings in a 96-well format

    PubMed Central

    2011-01-01

    The increasing popularity of systems-based approaches to plant research has resulted in a demand for high throughput (HTP) methods to be developed. RNA extraction from multiple samples in an experiment is a significant bottleneck in performing systems-level genomic studies. Therefore we have established a high throughput method of RNA extraction from Arabidopsis thaliana to facilitate gene expression studies in this widely used plant model. We present optimised manual and automated protocols for the extraction of total RNA from 9-day-old Arabidopsis seedlings in a 96 well plate format using silica membrane-based methodology. Consistent and reproducible yields of high quality RNA are isolated averaging 8.9 μg total RNA per sample (~20 mg plant tissue). The purified RNA is suitable for subsequent qPCR analysis of the expression of over 500 genes in triplicate from each sample. Using the automated procedure, 192 samples (2 × 96 well plates) can easily be fully processed (samples homogenised, RNA purified and quantified) in less than half a day. Additionally we demonstrate that plant samples can be stored in RNAlater at -20°C (but not 4°C) for 10 months prior to extraction with no significant effect on RNA yield or quality. Additionally, disrupted samples can be stored in the lysis buffer at -20°C for at least 6 months prior to completion of the extraction procedure providing a flexible sampling and storage scheme to facilitate complex time series experiments. PMID:22136293

  16. Protein farnesyltransferase: measurement of enzymatic activity in 96-well format using TopCount microplate scintillation counting technology.

    PubMed

    Harwood, H J

    1995-04-10

    Protein farnesyltransferase (PFT) catalyzes the transfer of the farnesyl group of farnesyl pyrophosphate (FPP) to proteins ending with a carboxy-terminal CAAX motif, forming a thioether linkage to the cysteine residue of the protein. A method is described herein for measurement of PFT activity in 96-well format using TopCount microplate scintillation counting technology. This method has the advantages of requiring only a single transfer from reaction vessels or wells of a 96-well reaction plate to the filtration wells of a 96-well Packard UniFilter GF/B filtration plate following acid precipitation and of allowing liquid scintillation counting to be conducted directly in the filtration plate without the need for either removal of the filter from the plate or transfer of the filter to liquid scintillation vials prior to radioactivity assessment. Using rat brain cytosol as the source of PFT, H-ras as the source of farnesyl acceptor protein, and [1-3H]FPP as the farnesyl donor, the incorporation of radiolabeled farnesyl residues into H-ras was found to be a linear function of both the time of incubation at 37 degrees C (up to 75 min) and the concentration of rat brain cytosolic protein present during incubation (up to 40 micrograms protein), and to be dependent on the concentration of H-ras (Km = 1.1 microM) and FPP (Km = 0.6 microM) present in the incubation reaction. In the presence of 4 microM H-ras, 0.5 microM FPP, 4 mM MgCl2, and 20 microM ZnCl2, the specific activity of rat brain cytosolic PFT measured using this methodology was 0.253 +/- 0.036 (SD; n = 30) pmol H-ras farnesylated per minute of incubation at 37 degrees C per milligram cytosolic protein. The signal-to-noise ratio for H-ras farnesylation using this methodology averaged 25 relative to incubation in the absence of H-ras (background farnesylation of cytosolic proteins) and 50 relative to incubation in the absence of both H-ras and rat brain cytosol (background filter associated radioactivity

  17. 96-well format-based microfluidic platform for parallel interconnection of multiple multicellular spheroids.

    PubMed

    Kim, Jin-Young; Fluri, David A; Kelm, Jens M; Hierlemann, Andreas; Frey, Olivier

    2015-06-01

    In this article, we present a microfluidic platform, compatible with conventional 96-well formats, that enables facile and parallelized culturing and testing of spherical microtissues in a standard incubator. The platform can accommodate multiple microtissues (up to 66) of different cell types, formed externally by using the hanging-drop method, and enables microtissue interconnection through microfluidic channels for continuous media perfusion or dosage of substances. The platform contains 11 separate channels, and each channel has six tissue compartments. Primary rat liver tissues were cultured over 8 days, and multiple tumor tissues (HCT116) were exposed to various concentrations of 5-fluorouracil for platform characterization. PMID:25524491

  18. A novel 96-well gel-based assay for determining antifungal activity against filamentous fungi.

    PubMed

    Troskie, Anscha Mari; Vlok, Nicolas Maré; Rautenbach, Marina

    2012-12-01

    In recent years the global rise in antibiotic resistance and environmental consciousness lead to a renewed fervour to find and develop novel antibiotics, including antifungals. However, the influence of the environment on antifungal activity is often disregarded and many in vitro assays may cause the activity of certain antifungals to be overestimated or underestimated. The general antifungal test assays that are economically accessible to the majority of scientists primarily rely on visual examination or on spectrophotometric analysis. The effect of certain morphogenic antifungals, which may lead to hyperbranching of filamentous fungi, unfortunately renders these methods unreliable. To minimise the difficulties experienced as a result of hyperbranching, we developed a straightforward, economical 96-well gel-based method, independent of spectrophotometric analysis, for highly repeatable determination of antifungal activity. For the calculation of inhibition parameters, this method relies on the visualisation of assay results by digitisation. The antifungal activity results from our novel micro-gel dilution assay are comparable to that of the micro-broth dilution assay used as standard reference test of The Clinical and Laboratory Standard Institute. Furthermore, our economical assay is multifunctional as it permits microscopic analysis of the preserved assay results, as well as rendering highly reliable data. PMID:23089670

  19. A 96-well electrochemical method for the screening of enzymatic activities.

    PubMed

    Abdellaoui, Sofiène; Noiriel, Alexandre; Henkens, Robert; Bonaventura, Celia; Blum, Loïc J; Doumèche, Bastien

    2013-04-01

    The rapid electrochemical screening of enzyme activities in bioelectronics is still a challenging issue. In order to solve this problem, we propose to use a 96-well electrochemical assay. This system is composed of 96 screen-printed electrodes on a printed circuit board adapted from a commercial system (carbon is used as the working electrode and silver chloride as the counter/reference electrode). The associated device allows for the measurements on the 96 electrodes to be performed within a few seconds. In this work, we demonstrate the validity of the screening method with the commercial laccase from the fungus Trametes versicolor. The signal-to-noise ratio (S/N) is found to be the best way to analyze the electrochemical signals. The S/N follows a saturation-like mechanism with a dynamic linear range of two decades ranging from 0.5 to 75 ng of laccase (corresponding to enzymatic activities from 62 × 10(-6) to 9.37 × 10(-3) μmol min(-1)) and a sensitivity of 3027 μg(-1) at +100 mV versus Ag/AgCl. Laccase inhibitors (azide and fluoride anions), pH optima, and interfering molecules could also be identified within a few minutes. PMID:23461701

  20. Development of a novel 96-well format for liquid-liquid microextraction and its application in the HPLC analysis of biological samples.

    PubMed

    Borijihan, Guirong; Li, Youxin; Gao, Jianguo; Bao, James J

    2014-05-01

    A novel 96-well liquid-liquid microextraction system combined with modern HPLC was developed and used for the simultaneous analysis of 96 biological samples. The system made use of hollow fibers, a 96-well plate, and a plastic base with a center hole and a side hole. One end of the hollow fiber was sealed, while the other end was attached to one of the holes positioned at the center for the plastic base. The needle was inserted into the liquid from inside or outside of the hollow fiber through the center or the side holes, respectively. The system was tested with plasma samples containing three compounds, acidic indomethacin, neutral dexamethasone, and basic propafenone. Some parameters, such as the kind and dimension of hollow fiber, pH and salt concentration of the donor phase, the selection of organic solvent for the acceptor phase, and the extraction time were investigated. Under the optimization conditions, the Log D and drug concentration of indomethacin, dexamethasone, and propafenone in plasma and urine samples were analyzed. Then, the methodology was validated. The results demonstrated that ng/mL levels could be exactly and rapidly analyzed by our system, which was equipped with an auto-injection sampler, making sample analysis more convenient. PMID:24574156

  1. A microtitration agglutination test for detecting group E streptococcus infection in swine.

    PubMed

    Armstrong, C H; Wood, R L; Wessman, G E

    1982-04-01

    A microtitration agglutination test was developed and evaluated for detecting infection of swine with group E streptococci type IV, the most common causative agent of streptococcic lymphadenitis of swine. Whole cell agglutinogens representing group and type antigens of group E streptococci were tested in the microtitration agglutination test against reference antisera to Streptococcus groups A, B, C, D, E, F, G. H, K, L, M, N, O, P, Q, R, S and U, as well as specific antisera to types II, IV and V of group E. Group E specific agglutinogens were unsatisfactory in the microtitration agglutination test because of cross reactions with group P and U antisera and because of poor reproducibility of the test. Type specific agglutinogens of group E streptococci reacted only with their respective homologous antisera and not with any heterologous group antisera. None of the group E streptococci agglutinogens reacted with 52 normal swine sera. Agglutinogen made from group E streptococci type IV was selected for further evaluation in the microtitration agglutination test because group E streptococci types II and V are considered to be of minor importance in the etiology of streptococcic lymphadenitis of swine. Swine experimentally infected with a type IV strain developed significant titers in the microtitration agglutination test. All swine tested negative before exposure and seroconverted (titer >/=4) two to six weeks postexposure.The microtitration agglutination test was used by two different laboratories to test 187 duplicate samples of serum from infected swine. A total of 94.1% of the tests were read at either the same titer (48.1%) or a difference of not more than one dilution (46.0%) at the two laboratories. There was disagreement between the two laboratories in the test-positive test-negative status of 19 of the sera (10.2%). Titers of two of the sera differed by two dilutions (<4 at one laboratory and 8 at the other). The remaining 17 sera differed in titer by only one

  2. A Microtitration Agglutination Test for Detecting Group E Streptococcus Infection in Swine

    PubMed Central

    Armstrong, C.H.; Wood, R.L.; Wessman, G.E.

    1982-01-01

    A microtitration agglutination test was developed and evaluated for detecting infection of swine with group E streptococci type IV, the most common causative agent of streptococcic lymphadenitis of swine. Whole cell agglutinogens representing group and type antigens of group E streptococci were tested in the microtitration agglutination test against reference antisera to Streptococcus groups A, B, C, D, E, F, G. H, K, L, M, N, O, P, Q, R, S and U, as well as specific antisera to types II, IV and V of group E. Group E specific agglutinogens were unsatisfactory in the microtitration agglutination test because of cross reactions with group P and U antisera and because of poor reproducibility of the test. Type specific agglutinogens of group E streptococci reacted only with their respective homologous antisera and not with any heterologous group antisera. None of the group E streptococci agglutinogens reacted with 52 normal swine sera. Agglutinogen made from group E streptococci type IV was selected for further evaluation in the microtitration agglutination test because group E streptococci types II and V are considered to be of minor importance in the etiology of streptococcic lymphadenitis of swine. Swine experimentally infected with a type IV strain developed significant titers in the microtitration agglutination test. All swine tested negative before exposure and seroconverted (titer ≥4) two to six weeks postexposure. The microtitration agglutination test was used by two different laboratories to test 187 duplicate samples of serum from infected swine. A total of 94.1% of the tests were read at either the same titer (48.1%) or a difference of not more than one dilution (46.0%) at the two laboratories. There was disagreement between the two laboratories in the test-positive test-negative status of 19 of the sera (10.2%). Titers of two of the sera differed by two dilutions (<4 at one laboratory and 8 at the other). The remaining 17 sera differed in titer by only

  3. High-throughput microtitre plate-based assay for DNA topoisomerases.

    PubMed

    Taylor, James A; Burton, Nicolas P; Maxwell, Anthony

    2012-01-01

    We have developed a rapid, high-throughput assay for measuring the catalytic activity (DNA supercoiling or relaxation) of DNA topoisomerases. The assay utilizes intermolecular triplex formation between an immobilized triplex-forming oligo (TFO) and a triplex-forming region inserted into the plasmid substrate (pNO1), and capitalizes on the observation that supercoiled DNA forms triplexes more readily than relaxed DNA. Thus, supercoiled DNA is preferentially retained by the TFO under triplex-forming conditions while relaxed DNA can be washed away. Due to its high speed of sample analysis and reduced sample handling over conventional gel-based techniques, this assay can be used to screen chemical libraries for novel inhibitors of topoisomerases. PMID:22130995

  4. Single-step method for β-galactosidase assays in Escherichia coli using a 96-well microplate reader.

    PubMed

    Schaefer, Jorrit; Jovanovic, Goran; Kotta-Loizou, Ioly; Buck, Martin

    2016-06-15

    Historically, the lacZ gene is one of the most universally used reporters of gene expression in molecular biology. Its activity can be quantified using an artificial substrate, o-nitrophenyl-ß-d-galactopyranoside (ONPG). However, the traditional method for measuring LacZ activity (first described by J. H. Miller in 1972) can be challenging for a large number of samples, is prone to variability, and involves hazardous compounds for lysis (e.g., chloroform, toluene). Here we describe a single-step assay using a 96-well microplate reader with a proven alternative cell permeabilization method. This modified protocol reduces handling time by 90%. PMID:27036618

  5. Single-step method for β-galactosidase assays in Escherichia coli using a 96-well microplate reader

    PubMed Central

    Schaefer, Jorrit; Jovanovic, Goran; Kotta-Loizou, Ioly; Buck, Martin

    2016-01-01

    Historically, the lacZ gene is one of the most universally used reporters of gene expression in molecular biology. Its activity can be quantified using an artificial substrate, o-nitrophenyl-ß-d-galactopyranoside (ONPG). However, the traditional method for measuring LacZ activity (first described by J. H. Miller in 1972) can be challenging for a large number of samples, is prone to variability, and involves hazardous compounds for lysis (e.g., chloroform, toluene). Here we describe a single-step assay using a 96-well microplate reader with a proven alternative cell permeabilization method. This modified protocol reduces handling time by 90%. PMID:27036618

  6. Fast carbohydrate analysis via liquid chromatography coupled with ultra violet and electrospray ionization ion trap detection in 96-well format.

    PubMed

    Rühmann, Broder; Schmid, Jochen; Sieber, Volker

    2014-07-11

    A fast carbohydrate screening platform processible in 96-well format is described. The method is suitable for the determination of various carbohydrates out of complex mixtures as obtained by acidic hydrolysis of carbohydrates polymers. The chromatographic conditions for an efficient separation (12min) and the derivatization process with 1-phenyl-3-methyl-5-pyrazolone (PMP) were optimized for high resolution separation and simultaneous determination of deoxy-, amino-, anhydro-sugars as well as hexoses, pentoses, dimers, uronic acids and degradation products like furfural and hydroxymethylfurfural (HMF). The potential to quantify with UV- and MS-detector in the same range has been demonstrated for 20 different compounds. Finally, the matrix effects of the hydrolysis were positively evaluated. The micro scale hydrolysis and PMP-derivatization without any extraction or drying steps, both in 96-well format, result in a fast and intuitive sample preparation. In combination with a fast liquid chromatography coupled to UV and electrospray ionization ion trap detection (LC-UV-ESI-MS/MS) for the qualification and quantification of various sugars, dimers and degradation products, this method shows great performance in carbohydrate analysis. PMID:24861788

  7. Characterization of multiple platelet activation pathways in patients with bleeding as a high-throughput screening option: use of 96-well Optimul assay

    PubMed Central

    Lordkipanidzé, Marie; Lowe, Gillian C.; Kirkby, Nicholas S.; Chan, Melissa V.; Lundberg, Martina H.; Morgan, Neil V.; Bem, Danai; Nisar, Shaista P.; Leo, Vincenzo C.; Jones, Matthew L.; Mundell, Stuart J.; Daly, Martina E.; Mumford, Andrew D.; Warner, Timothy D.; Watson, Steve P.; Watson, Steve P.; Mumford, Andrew D.; Mundell, Stuart J.; Gissen, Paul; Daly, Martina E.; Lester, Will; Clark, Justin; Williams, Mike; Motwani, Jayashree; Marshall, Dianne; Nyatanga, Priscilla; Mann, Pat; Kirwan, Julie; Wilde, Jonathan; Dunkley, Tracey; Greenway, April; Makris, Michael; Pavord, Sue; Dattani, Rashesh; Grimley, Gerry Dolan Charlotte; Stokley, Simone; Astwood, Emma; Chang, Cherry; Foros, Merri; Trower, Linda; Thachil, Jecko; Hay, Charlie; Pike, Gill; Will, Andrew; Grainger, John; Foulkes, Matt; Fareh, Mona; Talks, Kate; Biss, Tina; Kesteven, Patrick; Hanley, John; Vowles, Julie; Basey, Lesley; Barnes, Michelle; Collins, Peter; Rayment, Rachel; Alikhan, Raza; Morris, Ana Guerrero Rebecca; Mansell, Dianne; Toh, Cheng Hock; Martlew, Vanessa; Murphy, Elaine; Lachmann, Robin; Rose, Peter; Chapman, Oliver; Lokare, Anand; Marshall, Kathryn; Khan, Naseem; Keeling, David; Giangrande, Paul; Austin, Steve; Bevan, David; Alamelu, Jayanthi

    2014-01-01

    Up to 1% of the population have mild bleeding disorders, but these remain poorly characterized, particularly with regard to the roles of platelets. We have compared the usefulness of Optimul, a 96-well plate-based assay of 7 distinct pathways of platelet activation to characterize inherited platelet defects in comparison with light transmission aggregometry (LTA). Using Optimul and LTA, concentration-response curves were generated for arachidonic acid, ADP, collagen, epinephrine, Thrombin receptor activating-peptide, U46619, and ristocetin in samples from (1) healthy volunteers (n = 50), (2) healthy volunteers treated with antiplatelet agents in vitro (n = 10), and (3) patients with bleeding of unknown origin (n = 65). The assays gave concordant results in 82% of cases (κ = 0.62, P < .0001). Normal platelet function results were particularly predictive (sensitivity, 94%; negative predictive value, 91%), whereas a positive result was not always substantiated by LTA (specificity, 67%; positive predictive value, 77%). The Optimul assay was significantly more sensitive at characterizing defects in the thromboxane pathway, which presented with normal responses with LTA. The Optimul assay is sensitive to mild platelet defects, could be used as a rapid screening assay in patients presenting with bleeding symptoms, and detects changes in platelet function more readily than LTA. This trial was registered at www.isrctn.org as #ISRCTN 77951167. PMID:24408324

  8. Characterization of multiple platelet activation pathways in patients with bleeding as a high-throughput screening option: use of 96-well Optimul assay.

    PubMed

    Lordkipanidzé, Marie; Lowe, Gillian C; Kirkby, Nicholas S; Chan, Melissa V; Lundberg, Martina H; Morgan, Neil V; Bem, Danai; Nisar, Shaista P; Leo, Vincenzo C; Jones, Matthew L; Mundell, Stuart J; Daly, Martina E; Mumford, Andrew D; Warner, Timothy D; Watson, Steve P

    2014-02-20

    Up to 1% of the population have mild bleeding disorders, but these remain poorly characterized, particularly with regard to the roles of platelets. We have compared the usefulness of Optimul, a 96-well plate-based assay of 7 distinct pathways of platelet activation to characterize inherited platelet defects in comparison with light transmission aggregometry (LTA). Using Optimul and LTA, concentration-response curves were generated for arachidonic acid, ADP, collagen, epinephrine, Thrombin receptor activating-peptide, U46619, and ristocetin in samples from (1) healthy volunteers (n = 50), (2) healthy volunteers treated with antiplatelet agents in vitro (n = 10), and (3) patients with bleeding of unknown origin (n = 65). The assays gave concordant results in 82% of cases (κ = 0.62, P < .0001). Normal platelet function results were particularly predictive (sensitivity, 94%; negative predictive value, 91%), whereas a positive result was not always substantiated by LTA (specificity, 67%; positive predictive value, 77%). The Optimul assay was significantly more sensitive at characterizing defects in the thromboxane pathway, which presented with normal responses with LTA. The Optimul assay is sensitive to mild platelet defects, could be used as a rapid screening assay in patients presenting with bleeding symptoms, and detects changes in platelet function more readily than LTA. This trial was registered at www.isrctn.org as #ISRCTN 77951167. PMID:24408324

  9. Development and validation of a 96-well cellular assay for the discovery of ALDH1A1 inhibitors.

    PubMed

    Ming, Wenyu; Ma, Wenzhen; Chen, Lisa H; Volk, Catherine; Michael, Mervyn Dodson; Xu, Yanping; Zhang, Fang; Wang, Xiaojun

    2013-07-01

    Retinoic acid, the active metabolite of vitamin A, plays important roles in various physiological and pathological processes. The two-step production of retinoic acid from vitamin A (retinol) is catalyzed by alcohol dehydrogenases and aldehyde dehydrogenases, which are potential therapeutic targets for numerous diseases, such as obesity, diabetes, and cancer. Currently, the lack of a suitable high-throughput cellular assay hinders efforts to identify therapeutic small molecular inhibitors of aldehyde dehydrogenase, such as ALDH1A1. In this report, we utilized high-content imaging technology and a commercially available cell permeable ALDH substrate to develop a 96-well cellular ALDH1A1 assay. This assay has a robust and sensitive readout and is amenable to automation. With this cellular assay, we identified potent selective ALDH1A1 inhibitors to explore the role of retinoic acid production in various preclinical disease models. PMID:23957476

  10. The BUME method: a novel automated chloroform-free 96-well total lipid extraction method for blood plasma[S

    PubMed Central

    Löfgren, Lars; Ståhlman, Marcus; Forsberg, Gun-Britt; Saarinen, Sinikka; Nilsson, Ralf; Hansson, Göran I.

    2012-01-01

    Lipid extraction from biological samples is a critical and often tedious preanalytical step in lipid research. Primarily on the basis of automation criteria, we have developed the BUME method, a novel chloroform-free total lipid extraction method for blood plasma compatible with standard 96-well robots. In only 60 min, 96 samples can be automatically extracted with lipid profiles of commonly analyzed lipid classes almost identically and with absolute recoveries similar or better to what is obtained using the chloroform-based reference method. Lipid recoveries were linear from 10–100 µl plasma for all investigated lipids using the developed extraction protocol. The BUME protocol includes an initial one-phase extraction of plasma into 300 µl butanol:methanol (BUME) mixture (3:1) followed by two-phase extraction into 300 µl heptane:ethyl acetate (3:1) using 300 µl 1% acetic acid as buffer. The lipids investigated included the most abundant plasma lipid classes (e.g., cholesterol ester, free cholesterol, triacylglycerol, phosphatidylcholine, and sphingomyelin) as well as less abundant but biologically important lipid classes, including ceramide, diacylglycerol, and lyso-phospholipids. This novel method has been successfully implemented in our laboratory and is now used daily. We conclude that the fully automated, high-throughput BUME method can replace chloroform-based methods, saving both human and environmental resources. PMID:22645248

  11. RSV Growth and Quantification by Microtitration and qRT-PCR Assays.

    PubMed

    Caidi, Hayat; Harcourt, Jennifer L; Haynes, Lia M

    2016-01-01

    Defective interfering viral particles have been reported as important determinants of the course of viral infection, and they can markedly temper the virulence of the infection. Here, we describe a simple method, based on limiting dilution, for the removal of defective interfering particles from RSV. This method results in a high-titer viral preparation from both HEp-2 and Vero cell lines. We evaluated two concentrations of sucrose to stabilize the virus preparation, and demonstrate that RSV is stable when prepared and stored in 25 % sucrose at -152 °C. In addition, this chapter describes some commonly used methods of RSV titration, detection using microtitration and quantitative real-time RT-PCR, and the use of immunostaining for antigenic characterization. PMID:27464684

  12. Determination of suvorexant in human plasma using 96-well liquid-liquid extraction and HPLC with tandem mass spectrometric detection.

    PubMed

    Breidinger, S A; Simpson, R C; Mangin, E; Woolf, E J

    2015-10-01

    A method, using liquid chromatography with tandem mass spectrometric detection (LC-MS/MS), was developed for the determination of suvorexant (MK-4305, Belsomra(®)), a selective dual orexin receptor antagonist for the treatment insomnia, in human plasma over the concentration range of 1-1000ng/mL. Stable isotope labeled (13)C(2)H3-suvorexant was used as an internal standard. The sample preparation procedure utilized liquid-liquid extraction, in the 96-well format, of a 100μL plasma sample with methyl t-butyl ether. The compounds were chromatographed under isocratic conditions on a Waters dC18 (50×2.1mm, 3μm) column with a mobile phase consisting of 30/70 (v/v %) 10mM ammonium formate, pH3/acetonitrile at a flow rate of 0.3mL/min. Multiple reaction monitoring of the precursor-to-product ion pairs for suvorexant (m/z 451→186) and (13)C(2)H3-suvorexant (m/z 455→190) on an Applied Biosystems API 4000 tandem mass spectrometer was used for quantitation. Intraday assay precision, assessed in six different lots of control plasma, was within 10% CV at all concentrations, while assay accuracy ranged from 95.6 to 105.0% of nominal. Quality control (QC) samples in plasma were stored at -20°C. Initial within day analysis of QCs after one freeze-thaw cycle showed accuracy within 9.5% of nominal with precision (CV) of 6.7% or less. The plasma QC samples were demonstrated to be stable for up to 25 months at -20°C. The method described has been used to support clinical studies during Phase I through III of clinical development. PMID:26343269

  13. A rapid and miniaturized method for the selection of microbial phenol degraders using colourimetric microtitration.

    PubMed

    Fayidh, Mohammed A; Kallary, Sabina; Babu, P Azhagu Saravana; Sivarajan, M; Sukumar, M

    2015-06-01

    A high-throughput method is described, consisting of a colourimetric microtitration for screening phenol-degrading microorganisms, using a mixture of 4-aminoantipyrine and potassium ferricyanide as the colour indicator. This contemporary study summarizes a new method to determine phenol-degrading bacteria isolated from different areas. The method was used for testing a total of 72 bacteria collected from the natural environment and five known strains obtained from diagnostic and research laboratories employing 200 mg/L phenol (the linear range saturation concentration). Depending on the change in colour indicator, the degradation profiles of 11 strains of bacteria are shown, of which seven strains were able to degrade more than 80 % of phenol within 6-8 h, while the other four strains took 12-24 h. Two of the environmentally isolated strains showed high efficiency of phenol degradation and were confirmed by the high-performance liquid chromatography analysis. These strains were identified by 16S rRNA sequencing as unique (Escherichia coli moh1 and Bacillus cereus moh2) and were deposited in the GenBank of NCBI. Two pathogenic strains (Uropathogenic E. coli and Salmonella sp.) were found to be the fast degraders of phenol, which is of medical concern, as phenol is generally used as a disinfectant in hospitals. This method can be used for the estimation and screening of phenol degraders in a single step, for its application in bioremediation as well as in hospitals for screening the phenol resistance of pathogens. PMID:25842173

  14. Soluble penicillin-binding protein 2a: beta-lactam binding and inhibition by non-beta-lactams using a 96-well format.

    PubMed

    Toney, J H; Hammond, G G; Leiting, B; Pryor, K D; Wu, J K; Cuca, G C; Pompliano, D L

    1998-01-01

    High level methicillin resistance in Staphylococcus aureus is dependent upon the acquisition of the mecA gene encoding penicillin-binding protein 2a (PBP2a). PBP2a is a member of a family of peptidoglycan biosynthetic enzymes involved in assembly of the cell wall in bacteria and is poorly inactivated by beta-lactam antibiotics. We describe a 96-well-filter binding assay using recombinant, soluble PBP2a which allows for kinetic measurement of penicillin binding. The deacylation rate constant for the PBP2a-penicillin G covalent complex was found to be 5.7 +/- 1.0 x 10(-5) s-1 at 30 degrees C (half-life of approximately 200 min). For the PBP2a acylation reaction, the value of K(m) (penicillin G) = 0.5 +/- 0.1 mM and kcat = 1 x 10(-3) s-1, which yields a second-order rate constant (kcat/K(m)) for inactivation of 2.0 M-1 s-1. Using this assay, several non-beta-lactam inhibitors including Cibacron blue have been found which exhibit IC50 values between 10 and 30 microM. The binding affinities of several carbapenems and beta-lactams correlated well between the filter binding assay described in this report and an electrophoretic assay for PBP2a using membranes prepared form methicillin-resistant S. aureus. PMID:9448849

  15. Paper microzone plates.

    PubMed

    Carrilho, Emanuel; Phillips, Scott T; Vella, Sarah J; Martinez, Andres W; Whitesides, George M

    2009-08-01

    This paper describes 96- and 384-microzone plates fabricated in paper as alternatives to conventional multiwell plates fabricated in molded polymers. Paper-based plates are functionally related to plastic well plates, but they offer new capabilities. For example, paper-microzone plates are thin (approximately 180 microm), require small volumes of sample (5 microL per zone), and can be manufactured from inexpensive materials ($0.05 per plate). The paper-based plates are fabricated by patterning sheets of paper, using photolithography, into hydrophilic zones surrounded by hydrophobic polymeric barriers. This photolithography used an inexpensive formulation photoresist that allows rapid (approximately 15 min) prototyping of paper-based plates. These plates are compatible with conventional microplate readers for quantitative absorbance and fluorescence measurements. The limit of detection per zone loaded for fluorescence was 125 fmol for fluorescein isothiocyanate-labeled bovine serum albumin, and this level corresponds to 0.02 the quantity of analyte per well used to achieve comparable signal-to-noise in a 96-well plastic plate (using a solution of 25 nM labeled protein). The limits of detection for absorbance on paper was approximately 50 pmol per zone for both Coomassie Brilliant Blue and Amaranth dyes; these values were 0.4 that required for the plastic plate. Demonstration of quantitative colorimetric correlations using a scanner or camera to image the zones and to measure the intensity of color, makes it possible to conduct assays without a microplate reader. PMID:19572563

  16. Determination of the HIV integrase inhibitor, MK-0518 (raltegravir), in human plasma using 96-well liquid-liquid extraction and HPLC-MS/MS.

    PubMed

    Merschman, S A; Vallano, P T; Wenning, L A; Matuszewski, B K; Woolf, E J

    2007-09-15

    An HPLC-MS/MS method was developed for the determination of MK-0518 (raltegravir), an HIV integrase inhibitor, in human plasma over the concentration range of 2-1000 ng/mL. Stable isotope labeled (13)C(6)-MK-0518 was used as an internal standard. The sample preparation procedure utilized liquid-liquid extraction with hexane:methylene chloride in the 96-well format with a 200 microL plasma sample size. The compounds were chromatographed on an Ace C(18) (50 x 3.0 mm, 3 microm, titanium frits) column with 42.5/57.5 (v/v %) 0.1mM EDTA in 0.1% formic acid/methanol mobile phase at a flow rate of 0.5 mL/min. Multiple reaction monitoring of the precursor-to-product ion pairs for MK-0518 (m/z 445-->109) and (13)C(6)-MK-0518 (m/z 451-->367) on an Applied Biosystem API 4000 HPLC-MS/MS was used for quantitation. Intraday precision of standard curve concentrations in five different lots of control plasma was within 3.2%, while accuracy ranged from 94.8 to 106.8%. The mean extraction recovery of spiked plasma samples was 87%. Quality control (QC) samples were stored at -20 degrees C. Initial within day analysis showed QC accuracy within 7.5% of nominal with precision of 3.1% or less. The plasma QC samples were demonstrated to be stable for up to 23 months at -20 degrees C. The method described has been used to support over 18 clinical studies during Phase I through III of clinical development. PMID:17644453

  17. Simultaneous determination of a novel KDR kinase inhibitor and its N-oxide metabolite in human plasma using 96-well solid-phase extraction and liquid chromatography/tandem mass spectrometry.

    PubMed

    Xu, Yang; Du, Lihong; Soli, Eric D; Braun, Matthew P; Dean, Dennis C; Musson, Donald G

    2005-03-25

    To support pharmacokinetic studies, a selective and sensitive liquid chromatography/tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the simultaneous determination of a novel KDR kinase inhibitor (1) and its active metabolite (2) in human plasma. The method is fully automated using a Packard MultiPROBE II system and a TomTec Quadra 96 liquid handling workstation to perform sample preparation and solid-phase extraction (SPE). Following the extraction on a mixed-mode SPE using Oasis MCX 96-well plate, the analytes were separated on a Aquasil C18 column (50 mm x 2.1 mm, i.d., 3 microm) with a mobile phase consisting of acetonitrile/ammonium acetate buffer (5 mM, pH 5.0) (60/40, v/v). The run time for each injection was 4.5 min with the retention times of approximately 2.0 and 2.7 min for 1 and 2 respectively, at a flow rate of 0.25 mL/min. A tandem mass spectrometric detection was conducted using multiple reaction monitoring (MRM) under the positive ion mode with a turbo ion-spray interface. The linear ranges of the calibration curves were 0.05-400 ng/mL for 1 and 0.1-400 ng/mL for 2 on a PE Sciex API 4000 LC-MS/MS system. The lower limits of quantitation (LLOQ) of the assay were 0.05 and 0.1 ng/mL for 1 and 2 respectively, when 0.4 mL of plasma was processed. Intra-day assay precision (using five standard curves prepared by spiking compounds to five lots of plasma) was less than 4.9% for 1 and less than 9.6% for 2 on each concentration. Assay accuracy was found to be 95.1-104.6% of nominal for 1 standards and 93.5-105.6% for 2 standards. QC samples were stable when kept at room temperature for 4 h, at -70 degrees C for 10 days, and after three freeze-thaw cycles. The extraction recoveries were 80%, 83% and 84% for 1 and 2 and I.S. respectively, and no significant matrix effects were observed. The method was successfully applied to plasma samples from clinical studies after oral administration of compound 1. PMID:15686997

  18. Application of a novel microtitre plate-based assay for the discovery of new inhibitors of DNA gyrase and DNA topoisomerase VI.

    PubMed

    Taylor, James A; Mitchenall, Lesley A; Rejzek, Martin; Field, Robert A; Maxwell, Anthony

    2013-01-01

    DNA topoisomerases are highly exploited targets for antimicrobial drugs. The spread of antibiotic resistance represents a significant threat to public health and necessitates the discovery of inhibitors that target topoisomerases in novel ways. However, the traditional assays for topoisomerase activity are not suitable for the high-throughput approaches necessary for drug discovery. In this study we validate a novel assay for screening topoisomerase inhibitors. A library of 960 compounds was screened against Escherichia coli DNA gyrase and archaeal Methanosarcina mazei DNA topoisomerase VI. Several novel inhibitors were identified for both enzymes, and subsequently characterised in vitro and in vivo. Inhibitors from the M. mazei topoisomerase VI screen were tested for their ability to inhibit Arabidopsis topoisomerase VI in planta. The data from this work present new options for antibiotic drug discovery and provide insight into the mechanism of topoisomerase VI. PMID:23469129

  19. β-Cyclodextrin enhanced on-line organic solvent field-amplified sample stacking in capillary zone electrophoresis for analysis of ambroxol in human plasma, following liquid-liquid extraction in the 96-well format.

    PubMed

    Li, Ji; Bi, Youwei; Wang, Li; Sun, Fanlu; Chen, Zhao; Xu, Guili; Fan, Guorong

    2012-07-01

    A field-amplified sample stacking (FASS) and capillary zone electrophoresis (CZE) method is described for the quantification of ambroxol hydrochloride in human plasma, following liquid-liquid extraction in the 96-well format. The separation was carried out at 25 °C in a 31.2 cm × 75 μm fused-silica capillary with an applied voltage of 15 kV. The background electrolyte (BGE) was composed of 6.25 mM borate-25 mM phosphate (pH 3.0) and 1mM β-cyclodextrin. The detection wavelength was 210 nm. Clean-up and preconcentration of plasma biosamples were developed by 96-well format liquid-liquid extraction (LLE). In this study, FASS in combination with β-cyclodextrin enhanced the sensitivity about 60-70 fold in total. The method was suitably validated with respect to stability, specificity, linearity, lower limit of quantitation, accuracy, precision, extraction recovery and robustness. The calibration graph was linear for ambroxol hydrochloride from 2 to 500 ng/ml. The lower limit of quantification was 2 ng/ml. The intra- and inter-day precisions of lowest limit of quantification (LLOQ) were 9.61 and 11.80%, respectively. The method developed was successfully applied to the evaluation of clinical pharmacokinetic study of ambroxol hydrochloride tablet after oral administration to 12 healthy volunteers. PMID:22464560

  20. Microtiter plate-based antibody microarrays for bacteria and toxins

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Research has focused on the development of rapid biosensor-based, high-throughput, and multiplexed detection of pathogenic bacteria in foods. Specifically, antibody microarrays in 96-well microtiter plates have been generated for the purpose of selective detection of Shiga toxin-producing E. coli (...

  1. Copolymeric hexyl acrylate-methacrylic acid microspheres - surface vs. bulk reactive carboxyl groups. Coulometric and colorimetric determination and analytical applications for heterogeneous microtitration.

    PubMed

    Stelmach, Emilia; Maksymiuk, Krzysztof; Michalska, Agata

    2016-10-01

    Copolymeric acrylate microspheres were prepared from hexyl acrylate using different amounts of methacrylic acid, resulting in a series of microspheres of gradually changing properties. The distribution of carboxyl groups - between surface and bulk of microspheres was evaluated. Bulk reactive carboxyl groups were determined using reverse coulometric titration with H(+) ions, following hydroxide ions have been generated and allowed to react with microspheres in the first step. It was found that the number of reactive carboxyl groups available in copolymeric microspheres is lower compared to number of methacrylic acid units used for polymerization process. Moreover, there is correlation between the number of groups introduced and found to be reactive in microspheres. On the other hand, the number of surface reactive groups was proportional to the number of groups introduced in course of polymerization. Thus, the surface reactive groups can be used as reagent, in novel heterogeneous microtitration procedure, in which a constant number of microspheres of different carboxyl groups contents is introduced to the sample to react with the analyte. The applicability of novel proposed method was tested on the example of Ni(2+) determination. PMID:27474305

  2. Validation of a sensitive and automated 96-well solid-phase extraction liquid chromatography-tandem mass spectrometry method for the determination of desloratadine and 3-hydroxydesloratadine in human plasma.

    PubMed

    Yang, Liyu; Clement, Robert P; Kantesaria, Bhavna; Reyderman, Larisa; Beaudry, Francis; Grandmaison, Charles; Di Donato, Lorella; Masse, Robert; Rudewicz, Patrick J

    2003-07-25

    To support clinical development, a liquid chromatographic-tandem mass spectrometric (LC-MS-MS) method was developed and validated for the determination of desloratadine (descarboethoxyloratadine) and 3-OH desloratadine (3-hydroxydescarboethoxyloratadine) concentrations in human plasma. The method consisted of automated 96-well solid-phase extraction for sample preparation and liquid chromatography/turbo ionspray tandem mass spectrometry for analysis. [2H(4)]Desloratadine and [2H(4)]3-OH desloratadine were used as internal standards (I.S.). A quadratic regression (weighted 1/concentration(2)) gave the best fit for calibration curves over the concentration range of 25-10000 pg/ml for both desloratadine and 3-OH desloratadine. There was no interference from endogenous components in the blank plasma tested. The accuracy (%bias) at the lower limit of quantitation (LLOQ) was -12.8 and +3.4% for desloratadine and 3-OH desloratadine, respectively. The precision (%CV) for samples at the LLOQ was 15.1 and 10.9% for desloratadine and 3-OH desloratadine, respectively. For quality control samples at 75, 1000 and 7500 pg/ml, the between run %CV was

  3. Plate motion

    SciTech Connect

    Gordon, R.G. )

    1991-01-01

    The motion of tectonic plates on the earth is characterized in a critical review of U.S. research from the period 1987-1990. Topics addressed include the NUVEL-1 global model of current plate motions, diffuse plate boundaries and the oceanic lithosphere, the relation between plate motions and distributed deformations, accelerations and the steadiness of plate motions, the distribution of current Pacific-North America motion across western North America and its margin, plate reconstructions and their uncertainties, hotspots, and plate dynamics. A comprehensive bibliography is provided. 126 refs.

  4. Miniaturized plate readers for low-cost, high-throughput phenotypic screening.

    PubMed

    Jensen, Paul A; Dougherty, Bonnie V; Moutinho, Thomas J; Papin, Jason A

    2015-02-01

    We present a miniaturized plate reader for measuring optical density in 96-well plates. Our standalone reader fits in most incubators, environmental chambers, or biological containment suites, allowing users to leverage their existing laboratory infrastructure. The device contains no moving parts, allowing an entire 96-well plate to be read several times per second. We demonstrate how the fast sampling rate allows our reader to detect small changes in optical density, even when the device is placed in a shaking incubator. A wireless communication module allows remote monitoring of multiple devices in real time. These features allow easy assembly of multiple readers to create a scalable, accurate solution for high-throughput phenotypic screening. PMID:25366331

  5. Miniaturized Plate Readers for Low-Cost, High-Throughput Phenotypic Screening

    PubMed Central

    Jensen, Paul A.; Dougherty, Bonnie V.; Moutinho, Thomas J.

    2015-01-01

    We present a miniaturized plate reader for measuring optical density in 96-well plates. Our standalone reader fits in most incubators, environmental chambers, or biological containment suites, allowing users to leverage their existing laboratory infrastructure. The device contains no moving parts, allowing an entire 96-well plate to be read several times per second. We demonstrate how the fast sampling rate allows our reader to detect small changes in optical density, even when the device is placed in a shaking incubator. A wireless communication module allows remote monitoring of multiple devices in real time. These features allow easy assembly of multiple readers to create a scalable, accurate solution for high-throughput phenotypic screening. PMID:25366331

  6. Use of a Fluorometric Imaging Plate Reader in high-throughput screening

    NASA Astrophysics Data System (ADS)

    Groebe, Duncan R.; Gopalakrishnan, Sujatha; Hahn, Holly; Warrior, Usha; Traphagen, Linda; Burns, David J.

    1999-04-01

    High-throughput screening (HTS) efforts at Abbott Laboratories have been greatly facilitated by the use of a Fluorometric Imaging Plate Reader. The FLIPR consists of an incubated cabinet with integrated 96-channel pipettor and fluorometer. An argon laser is used to excite fluorophores in a 96-well microtiter plate and the emitted fluorometer. An argon laser is used to excite fluorophores in a 96-well microtiter plate and the emitted fluorescence is imaged by a cooled CCD camera. The image data is downloaded from the camera and processed to average the signal form each well of the microtiter pate for each time point. The data is presented in real time on the computer screen, facilitating interpretation and trouble-shooting. In addition to fluorescence, the camera can also detect luminescence form firefly luciferase.

  7. Peen plating

    NASA Technical Reports Server (NTRS)

    Babecki, A. J. (Inventor); Haehner, C. L.

    1973-01-01

    A process for metal plating which comprises spraying a mixture of metallic powder and small peening particles at high velocity against a surface is described. The velocity must be sufficient to impact and bond metallic powder onto the surface. In the case of metal surfaces, the process has as one of its advantages providing mechanical working (hardening) of the surface simultaneously with the metal plating.

  8. Laboratory assessment of anti-thrombotic therapy in heart failure, atrial fibrillation and coronary artery disease: insights using thrombelastography and a micro-titre plate assay of thrombogenesis and fibrinolysis.

    PubMed

    Lau, Y C; Xiong, Q; Ranjit, P; Lip, G Y H; Blann, A D

    2016-08-01

    As heart failure, coronary artery disease and atrial fibrillation all bring a risk of thrombosis, anti-thrombotic therapy is recommended. Despite such treatment, major cardiovascular events such as myocardial infarction and stroke still occur, implying inadequate suppression of thrombus formation. Accordingly, identification of patients whose haemostasis remains unimpaired by treatment is valuable. We compared indices for assessing thrombogenesis and fibrinolysis by two different techniques in patients on different anti-thrombotic agents, i.e. aspirin or warfarin. We determined fibrin clot formation and fibrinolysis by a microplate assay and thromboelastography, and platelet marker soluble P selectin in 181 patients with acute or chronic heart failure, coronary artery disease who were taking either aspirin or warfarin. Five thromboelastograph indices and four microplate assay indices were different on aspirin versus warfarin (p < 0.05). In multivariate regression analysis, only microplate assay indices rate of clot formation and rate of clot dissolution were independently related to aspirin or warfarin use (p ≤ 0.001). Five microplate assay indices, but no thrombelastograph index, were different (p < 0.001) in aspirin users. Three microplate assay indices were different (p ≤ 0.002) in warfarin users. The microplate assay indices of lag time and rate of clot formation were abnormal in chronic heart failure patients on aspirin, suggesting increased risk of thrombosis despite anti-platelet use. Soluble P selectin was lower in patients on aspirin (p = 0.0175) but failed to correlate with any other index of haemostasis. The microplate assay shows promise as a tool for dissecting thrombogenesis and fibrinolysis in cardiovascular disease, and the impact of antithrombotic therapy. Prospective studies are required to determine a role in predicting thrombotic risk. PMID:26942726

  9. A Compact Immunoassay Platform Based on a Multicapillary Glass Plate

    PubMed Central

    Xue, Shuhua; Zeng, Hulie; Yang, Jianmin; Nakajima, Hizuru; Uchiyama, Katsumi

    2014-01-01

    A highly sensitive, rapid immunoassay performed in the multi-channels of a micro-well array consisting of a multicapillary glass plate (MCP) and a polydimethylsiloxane (PDMS) slide is described. The micro-dimensions and large surface area of the MCP permitted the diffusion distance to be decreased and the reaction efficiency to be increased. To confirm the concept of the method, human immunoglobulin A (h-IgA) was measured using both the proposed immunoassay system and the traditional 96-well plate method. The proposed method resulted in a 1/5-fold decrease of immunoassay time, and a 1/56-fold cut in reagent consumption with a 0.05 ng/mL of limit of detection (LOD) for IgA. The method was also applied to saliva samples obtained from healthy volunteers. The results correlated well to those obtained by the 96-well plate method. The method has the potential for use in disease diagnostic or on-site immunoassays. PMID:24859022

  10. One plate, two plates, a thousand plates. How crystallisation changes with large numbers of samples.

    PubMed

    Newman, Janet

    2011-09-01

    Turning commercial lab automation into a high-throughput centre requires an underlying process, and implementing checks to ensure that the process is working as it should. At the Collaborative Crystallisation Centre (C3), protein samples from local, national and international groups are set up in crystallisation screening and optimisation experiments with two thousand 96 well plates being set up each year. During its five years of operation, the C3 has implemented a series of enabling protocols - from simple 'reality checks' to determine if a screen has evaporated during storage to more sophisticated systems such as a sample labelling and tracking system. The most important - and perhaps surprising - lesson has been how much effort is required to effectively communicate between the centre and its clients, as well as between the centre's staff members. It is easy to confuse the concept of 'high throughput' in any field with the idea of setting up an experiment quickly. Although automation can be used to set up a single experiment more rapidly than can be done by hand, the distinguishing feature of a high throughput technology is the sustainability of the increased rate. PMID:21571072

  11. Multiplexed chemiluminescent assays in ArrayPlates for high-throughput measurement of gene expression

    NASA Astrophysics Data System (ADS)

    Martel, Ralph R.; Rounseville, Matthew P.; Botros, Ihab W.; Seligmann, Bruce E.

    2002-06-01

    Multiplexed Molecular Profiling (MMP) assays for drug discovery are performed in ArrayPlates. ArrayPlates are 96- well microtiter plates that contain a 16-element array at the bottom of each well. Each element within an array measures one analyte in a sample. A CCD imager records the quantitative chemiluminescent readout of all 1,536 elements in a 96-well plate simultaneously. Since array elements are reagent modifiable by the end-user, ArrayPlates can be adapted to a broad range of nucleic acid- and protein-based assays. Such multiplexed assays are rapidly established, flexible, robust, automation-friendly and cost-effective. Nucleic acid assays in ArrayPlates can detect DNA and RNA, including SNPs and ESTs. A multiplexed mRNA assay to measure the expression of 16 genes is described. The assay combines a homogeneous nuclease protection assay with subsequent probe immobilization to the array by means of a sandwich hybridization followed with chemiluminescent detection. This assay was used to examine cells grown and treated in microplates and avoided cloning, transfection, RNA insolation, reverse transcription, amplification and fluorochrome labeling. Standard deviations for the measurement of 16 genes ranged from 3 percent to 13 percent in samples of 30,000 cells. Such ArrayPlates transcription assays are useful in drug discovery and development for target validation, screening, lead optimization, metabolism and toxicity profiling. Chemiluminescent detection provides ArrayPlates assays with high signal-to-noise readout and simplifies imager requirements. Imaging a 2D surface that contains arrays simplifies lens requirements relative to imaging columns of liquid in microtiter plate wells. The Omix imager for ArrayPlates is described.

  12. Sputtering and ion plating

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The proceedings of a conference on sputtering and ion plating are presented. Subjects discussed are: (1) concepts and applications of ion plating, (2) sputtering for deposition of solid film lubricants, (3) commercial ion plating equipment, (4) industrial potential for ion plating and sputtering, and (5) fundamentals of RF and DC sputtering.

  13. MerMade: An Oligodeoxyribonucleotide Synthesizer for High Throughput Oligonucleotide Production in Dual 96-Well Plates

    PubMed Central

    Rayner, Simon; Brignac, Stafford; Bumeister, Ron; Belosludtsev, Yuri; Ward, Travis; Grant, O’dell; O’Brien, Kevin; Evans, Glen A.; Garner, Harold R.

    1998-01-01

    We have designed and constructed a machine that synthesizes two standard 96-well plates of oligonucleotides in a single run using standard phosphoramidite chemistry. The machine is capable of making a combination of standard, degenerate, or modified oligos in a single plate. The run time is typically 17 hr for two plates of 20-mers and a reaction scale of 40 nm. The reaction vessel is a standard polypropylene 96-well plate with a hole drilled in the bottom of each well. The two plates are placed in separate vacuum chucks and mounted on an xy table. Each well in turn is positioned under the appropriate reagent injection line and the reagent is injected by switching a dedicated valve. All aspects of machine operation are controlled by a Macintosh computer, which also guides the user through the startup and shutdown procedures, provides a continuous update on the status of the run, and facilitates a number of service procedures that need to be carried out periodically. Over 25,000 oligos have been synthesized for use in dye terminator sequencing reactions, polymerase chain reactions (PCRs), hybridization, and RT–PCR. Oligos up to 100 bases in length have been made with a coupling efficiency in excess of 99%. These machines, working in conjunction with our oligo prediction code are particularly well suited to application in automated high throughput genomic sequencing. PMID:9685322

  14. Efficient DNA sequencing on microtiter plates using dried reagents and Bst DNA polymerase.

    PubMed

    Earley, J J; Kuivaniemi, H; Prockop, D J; Tromp, G

    1993-01-01

    Sequenase, Taq DNA polymerase and Bst DNA polymerase were tested for sequencing of DNA on microtiter plates using dried down reagents. Several parameters were investigated to expedite the drying process while minimizing damage to the enzyme. Sequenase did not tolerate drying very well, and frequently generated sequences with weak signals and many sites of premature termination. With Taq DNA polymerase it was possible to obtain sequences of good quality. However, there was considerable variation of results between experiments and between batches of microtiter plates. Bst DNA polymerase generated sequences of excellent quality. It was stable for more than a week in dried-down state at -20 degrees C and at least overnight at room temperature. The method described here using Bst DNA polymerase is well suited for laboratory robots and workstations that typically employ 96-well microtiter plates. PMID:8173079

  15. Earth's Decelerating Tectonic Plates

    SciTech Connect

    Forte, A M; Moucha, R; Rowley, D B; Quere, S; Mitrovica, J X; Simmons, N A; Grand, S P

    2008-08-22

    Space geodetic and oceanic magnetic anomaly constraints on tectonic plate motions are employed to determine a new global map of present-day rates of change of plate velocities. This map shows that Earth's largest plate, the Pacific, is presently decelerating along with several other plates in the Pacific and Indo-Atlantic hemispheres. These plate decelerations contribute to an overall, globally averaged slowdown in tectonic plate speeds. The map of plate decelerations provides new and unique constraints on the dynamics of time-dependent convection in Earth's mantle. We employ a recently developed convection model constrained by seismic, geodynamic and mineral physics data to show that time-dependent changes in mantle buoyancy forces can explain the deceleration of the major plates in the Pacific and Indo-Atlantic hemispheres.

  16. ASSEMBLY OF PARALLEL PLATES

    DOEpatents

    Groh, E.F.; Lennox, D.H.

    1963-04-23

    This invention is concerned with a rigid assembly of parallel plates in which keyways are stamped out along the edges of the plates and a self-retaining key is inserted into aligned keyways. Spacers having similar keyways are included between adjacent plates. The entire assembly is locked into a rigid structure by fastening only the outermost plates to the ends of the keys. (AEC)

  17. Accelerated plate tectonics.

    PubMed

    Anderson, D L

    1975-03-21

    The concept of a stressed elastic lithospheric plate riding on a viscous asthenosphere is used to calculate the recurrence interval of great earthquakes at convergent plate boundaries, the separation of decoupling and lithospheric earthquakes, and the migration pattern of large earthquakes along an arc. It is proposed that plate motions accelerate after great decoupling earthquakes and that most of the observed plate motions occur during short periods of time, separated by periods of relative quiescence. PMID:17799689

  18. Plating Tank Control Software

    1998-03-01

    The Plating Tank Control Software is a graphical user interface that controls and records plating process conditions for plating in high aspect ratio channels that require use of low current and long times. The software is written for a Pentium II PC with an 8 channel data acquisition card, and the necessary shunt resistors for measuring currents in the millampere range.

  19. Rotatable shear plate interferometer

    DOEpatents

    Duffus, Richard C.

    1988-01-01

    A rotatable shear plate interferometer comprises a transparent shear plate mounted obliquely in a tubular supporting member at 45.degree. with respect to its horizontal center axis. This tubular supporting member is supported rotatably around its center axis and a collimated laser beam is made incident on the shear plate along this center axis such that defocus in different directions can be easily measured.

  20. An improved plating process

    NASA Technical Reports Server (NTRS)

    Askew, John C.

    1994-01-01

    An alternative to the immersion process for the electrodeposition of chromium from aqueous solutions on the inside diameter (ID) of long tubes is described. The Vessel Plating Process eliminates the need for deep processing tanks, large volumes of solutions, and associated safety and environmental concerns. Vessel Plating allows the process to be monitored and controlled by computer thus increasing reliability, flexibility and quality. Elimination of the trivalent chromium accumulation normally associated with ID plating is intrinsic to the Vessel Plating Process. The construction and operation of a prototype Vessel Plating Facility with emphasis on materials of construction, engineered and operational safety and a unique system for rinse water recovery are described.

  1. Automated cytopathic effect (CPE) assays.

    PubMed

    McAleer, W J; Miller, W J; Hurni, W M; Machlowitz, R A; Hilleman, M R

    1983-07-01

    An automated CPE procedure has been developed that increases the precision and ease of performing titrations of measles, mumps and rubella viruses in vaccine materials. By this procedure, additions of cell suspensions and reagents and the dilution of samples are performed automatically by a modified Dynatiter instrument, using 96-well microtitre plates. Cell monolayers are stained with carbolfuchsin dye to eliminate the need for microscopic examination. Finally, the trays are read in an optical scanner and the end points calculated automatically by a programmable calculator. The increased accuracy and precision attained by performing greater numbers of replicate assays at reasonable cost will be of particular value to vaccine manufacturers. PMID:6885830

  2. Multicolor printing plate joining

    NASA Technical Reports Server (NTRS)

    Waters, W. J. (Inventor)

    1984-01-01

    An upper plate having ink flow channels and a lower plate having a multicolored pattern are joined. The joining is accomplished without clogging any ink flow paths. A pattern having different colored parts and apertures is formed in a lower plate. Ink flow channels each having respective ink input ports are formed in an upper plate. The ink flow channels are coated with solder mask and the bottom of the upper plate is then coated with solder. The upper and lower plates are pressed together at from 2 to 5 psi and heated to a temperature of from 295 F to 750 F or enough to melt the solder. After the plates have cooled and the pressure is released, the solder mask is removed from the interior passageways by means of a liquid solvent.

  3. Hypervelocity plate acceleration

    SciTech Connect

    Marsh, S.P.; Tan, T.H.

    1991-01-01

    Shock tubes have been used to accelerate 1.5-mm-thick stainless steel plates to high velocity while retaining their integrity. The fast shock tubes are 5.1-cm-diameter, 15.2-cm-long cylinders of PBX-9501 explosive containing a 1.1-cm-diameter cylindrical core of low-density polystyrene foam. The plates have been placed directly in contact with one face of the explosive system. Plane-wave detonation was initiated on the opposite face. A Mach disk was formed in the imploding styrofoam core, which provided the impulse required to accelerate the metal plate to high velocity. Parametric studies were made on this system to find the effect of varying plate metal, plate thickness, foam properties, and addition of a barrel. A maximum plate velocity of 9.0 km/s has been observed. 6 refs., 17 figs.

  4. WFPDB: European Plate Archives

    NASA Astrophysics Data System (ADS)

    Tsvetkov, Milcho

    2007-08-01

    The Wide-Field Plate Database (WFPDB) gives an inventory of all wide-field (>~ 1 sq. deg) photographic observations archived in astronomical institutions over the world. So it facilitates and stimulates their use and preservation as a valuable source of information for future investigations in astronomy. At present WFPDB manages plate-index information for 25% of all existing plates providing on-line access from Sofia (http://www.skyarchive.org/search) and in CDS, Strasbourg. Here we present the new development of WFPDB as an instrument for searching of long term brightness variations of different sky objects stressing on the European photographic plate collections (from existing 2 million wide-field plates more than 55% are in Europe: Germany, Russia, Ukraine, Italy, Czech Republic, etc.). We comment examples of digitization (with flatbed scanners) of the European plate archives in Sonneberg, Pulkovo, Asiago, Byurakan, Bamberg, etc. and virtual links of WFPDB with European AVO, ADS, IBVS.

  5. GOLD PLATING PROCESS

    DOEpatents

    Seegmiller, R.

    1957-08-01

    An improved bath is reported for plating gold on other metals. The composition of the plating bath is as follows: Gold cyanide from about 15 to about 50 grams, potassium cyanide from about 70 to about 125 grams, and sulfonated castor oil from about 0.1 to about 10 cc. The gold plate produced from this bath is smooth, semi-hard, and nonporous.

  6. Plating methods, a survey

    NASA Technical Reports Server (NTRS)

    Berkowitz, J. B.; Emerson, N. H.

    1972-01-01

    Results are presented of a comprehensive search of the literature available, much of which has been generated by the research centers of NASA and its contractors, on plating and coating methods and techniques. Methods covered included: (1) electroplating from aqueous solutions; (2) electroplating from nonaqueous solutions; (3) electroplating from fused-salt baths; (4) electroforming; (5) electroless plating, immersion plating, and mirroring; (6) electroplating from gaseous plasmas; and (7) anodized films and conversion coatings.

  7. CALUTRON FACE PLATE

    DOEpatents

    Brobeck, W.M.

    1959-08-25

    The construction of a removable cover plate for a calutron tank is described. The plate is fabricated of a rectangular frame member to which is welded a bowed or dished plate of thin steel, reinforced with transverse stiffening ribs. When the tank is placed between the poles of a magnet, the plate may be pivoted away from the tank and magnet and is adapted to support the ion separation mechanism secured to its inner side as well as the vacuum load within the tank.

  8. PLATES WITH OXIDE INSERTS

    DOEpatents

    West, J.M.; Schumar, J.F.

    1958-06-10

    Planar-type fuel assemblies for nuclear reactors are described, particularly those comprising fuel in the oxide form such as thoria and urania. The fuel assembly consists of a plurality of parallel spaced fuel plate mennbers having their longitudinal side edges attached to two parallel supporting side plates, thereby providing coolant flow channels between the opposite faces of adjacent fuel plates. The fuel plates are comprised of a plurality of longitudinally extending tubular sections connected by web portions, the tubular sections being filled with a plurality of pellets of the fuel material and the pellets being thermally bonded to the inside of the tubular section by lead.

  9. Alteration of the aPA ELISA by UV exposure of polystyrene microtiter plates.

    PubMed

    Goldberg, J S; Wagenknecht, D R; McIntyre, J A

    1996-01-01

    Interlaboratory inconsistencies in antiphospholipid antibody (aPA) solid phase assays have prompted controversy in clinical laboratory testing for aPA. We found that the aPA ELISA can be influenced by the type of microtiter plate utilized and by the conditions in which the plates are stored. By exposing 96-well, flat-bottom polystyrene microtiter plates to short wave UV light (254 nm), the aPA ELISA signal decreased in a UV dose-dependent manner. No effect was seen with long wave UV light (366 nm). These results were independent of the antibody isotype under study or the phospholipid (PL) antigen used: anionic phosphatidylserine (PS) and cardiolipin (CL), or zwitterionic phosphatidylethanolamine (PE). Purified human beta 2-glycoprotein I (beta 2 GPI), a known cofactor for anionic PL, and rabbit anti-beta 2 GPI antisera were used to demonstrate that beta 2 GPI bound equally to UV treated and untreated microtiter plates. In contrast, recognition of beta 2 GPI on an anionic PL surface was decreased on UV treated plates, suggesting that UV exposure alters the lipid binding properties of the microliter plate. To determine whether UV exposure inhibited PL binding directly or caused a change in the way the PL was bound, the amount of PL bound to UV treated and untreated plates was measured by using fluorescent labeled PS and a fluorimeter. PS binding was decreased by 53% in UV treated wells as compared to untreated wells. These data show that short wave UV exposure reduces PL binding to polystyrene microtiter plates, thereby reducing the amount of beta 2 GPI bound to PL coated ELISA plates. Thus by using UV exposed microtiter plates, decreased or false-negative a PA ELISA results may be obtained for aPA positive plasmas. PMID:8887002

  10. Blue Willow Story Plates

    ERIC Educational Resources Information Center

    Fontes, Kris

    2009-01-01

    In the December 1997 issue of "SchoolArts" is a lesson titled "Blue Willow Story Plates" by Susan Striker. In this article, the author shares how she used this lesson with her middle-school students many times over the years. Here, she describes a Blue Willow plate painting project that her students made.

  11. Earthquakes and plate tectonics

    USGS Publications Warehouse

    Spall, H.

    1977-01-01

    An explanation is to be found in plate tectonics, a concept which has revolutionized thinking in the Earth sciences in the last 10 years. The theory of plate tectonics combines many of the ideas about continental drift (originally proposed in 1912 by Alfred Wegener in Germany) and sea-floor spreading (suggested originally by Harry Hess of Princeton University). 

  12. Rapid, Noninvasive Screening for Perturbations of Metabolism and Plant Growth Using Chlorophyll Fluorescence Imaging1

    PubMed Central

    Barbagallo, Romina P.; Oxborough, Kevin; Pallett, Kenneth E.; Baker, Neil R.

    2003-01-01

    A rapid, noninvasive technique involving imaging of chlorophyll fluorescence parameters for detecting perturbations of leaf metabolism and growth in seedlings is described. Arabidopsis seedlings were grown in 96-well microtitre plates for 4 d and then treated with eight herbicides with differing modes of action to induce perturbations in a range of different metabolic processes. Imaging of chlorophyll fluorescence emissions from 96 seedlings growing on a microtitre plate enabled images of a number of fluorescence parameters to be rapidly and simultaneously produced for the plants in each well. Herbicideinduced perturbations in metabolism, even in metabolic reactions not directly associated with photosynthetic metabolism, were detected from the changes in the images of fluorescence parameters considerably before any visual effects on seedling growth were observed. Evaluations of seedling growth were made from measurements of the area of chlorophyll fluorescence emission in images of plants growing in the 96-well plates. Decreased seedling growth related directly to herbicideinduced changes in the imaged chlorophyll fluorescence parameters. The applicability of this rapid-screening technique for metabolic perturbations in monocotyledonous species was demonstrated by treating Agrostis tenuis seedlings with Imazapyr, an inhibitor of branched-chain amino acid synthesis. PMID:12805581

  13. Turbine vane plate assembly

    DOEpatents

    Schiavo Jr., Anthony L.

    2006-01-10

    A turbine vane assembly includes a turbine vane having first and second shrouds with an elongated airfoil extending between. Each end of the airfoil transitions into a shroud at a respective junction. Each of the shrouds has a plurality of cooling passages, and the airfoil has a plurality of cooling passages extending between the first and second shrouds. A substantially flat inner plate and an outer plate are coupled to each of the first and second shrouds so as to form inner and outer plenums. Each inner plenum is defined between at least the junction and the substantially flat inner plate; each outer plenum is defined between at least the substantially flat inner plate and the outer plate. Each inner plenum is in fluid communication with a respective outer plenum through at least one of the cooling passages in the respective shroud.

  14. Earthquakes and plate tectonics.

    USGS Publications Warehouse

    Spall, H.

    1982-01-01

    Earthquakes occur at the following three kinds of plate boundary: ocean ridges where the plates are pulled apart, margins where the plates scrape past one another, and margins where one plate is thrust under the other. Thus, we can predict the general regions on the earth's surface where we can expect large earthquakes in the future. We know that each year about 140 earthquakes of magnitude 6 or greater will occur within this area which is 10% of the earth's surface. But on a worldwide basis we cannot say with much accuracy when these events will occur. The reason is that the processes in plate tectonics have been going on for millions of years. Averaged over this interval, plate motions amount to several mm per year. But at any instant in geologic time, for example the year 1982, we do not know, exactly where we are in the worldwide cycle of strain build-up and strain release. Only by monitoring the stress and strain in small areas, for instance, the San Andreas fault, in great detail can we hope to predict when renewed activity in that part of the plate tectonics arena is likely to take place. -from Author

  15. Lohse's historic plate archive

    NASA Astrophysics Data System (ADS)

    Tsvetkov, M.; Tsvetkova, K.; Richter, G.; Scholz, G.; Böhm, P.

    The description and the analysis of Oswald Lohse's astrophotographic plates, collected at the Astrophysical Observatory Potsdam in the period 1879 - 1889, are presented. 67 plates of the archive, taken with the greatest instrument of the observatory at that time - the refractor (D = 0.30 m, F = 5.40 m, scale = 38''/mm) and with the second heliographic objective (D = 0.13 m, F = 1.36 m, scale = 152''/mm) - - survived two world wars in relative good condition. The plate emulsions are from different manufacturers in the beginning of astrophotography (Gädicke, Schleussner, Beernaert, etc.). The sizes of the plates are usually 9x12 cm2, which corresponds to fields of 1.2deg and 5deg respectively for each instrument mentioned above. The average limiting magnitude is 13.0(pg). Besides of the plates received for technical experiments (work on photographic processes, testing of new instruments and methods of observations), the scientific observations follow programs for studies of planet surfaces, bright stars, some double stars, stellar clusters and nebulous objects. Lohse's archive is included into the Wide Field Plate Database (http://www.skyarchive.org) as the oldest systematic one, covering the fields of Orion (M42/43), Pleiades, h & chi Persei, M37, M3, M11, M13, M92, M31, etc. With the PDS 2020 GM+ microdensitometer of Münster University 10 archive plates were digitized.

  16. Cavity-Enhanced Immunoassay Measurements in Microtiter Plates Using BBCEAS.

    PubMed

    Bajuszova, Zuzana; Ali, Zulfiqur; Scott, Simon; Seetohul, L Nitin; Islam, Meez

    2016-05-17

    We report on the first detailed use of broadband cavity enhanced absorption spectroscopy (BBCEAS) as a detection system for immunoassay. A vertical R ≥ 0.99 optical cavity was integrated with a motorized XY stage, which functioned as a receptacle for 96-well microtiter plates. The custom-built cavity enhanced microplate reader was used to make measurements on a commercially available osteocalcin sandwich ELISA kit. A 30-fold increase in path length was obtained with a minimum detectable change in the absorption coefficient, αmin(t), of 5.3 × 10(-5) cm(-1) Hz(-1/2). This corresponded to a 39-fold increase in the sensitivity of measurement when directly compared to measurements in a conventional microplate reader. Separate measurements of a standard STREP-HRP colorimetric reaction in microtiter plates of differing optical quality produced an increase in sensitivity of up to 115-fold compared to a conventional microplate reader. The sensitivity of the developed setup compared favorably with previous liquid-phase cavity enhanced studies and approaches the sensitivity of typical fluorometric ELISAs. It could benefit any biochemical test which uses single pass absorption as a detection method, through either the label free detection of biologically important molecules at lower concentrations or the reduction in the amount of expensive biochemicals needed for a particular test, leading to cheaper tests. PMID:27089516

  17. Tectonic Plate Movement.

    ERIC Educational Resources Information Center

    Landalf, Helen

    1998-01-01

    Presents an activity that employs movement to enable students to understand concepts related to plate tectonics. Argues that movement brings topics to life in a concrete way and helps children retain knowledge. (DDR)

  18. Flat plate solar oven

    SciTech Connect

    Parikh, M.

    1981-01-01

    The construction of an Indian Rs. 186 (US $20.33) flat-plate solar oven is described. Detailed drawings are provided and relevant information on cooking times and temperature for different foods is given.

  19. Plate tectonics: Metamorphic myth

    NASA Astrophysics Data System (ADS)

    Korenaga, Jun

    2016-01-01

    Clear evidence for subduction-induced metamorphism, and thus the operation of plate tectonics on the ancient Earth has been lacking. Theoretical calculations indicate that we may have been looking for something that cannot exist.

  20. Violin plate modes.

    PubMed

    Gough, Colin

    2015-01-01

    As the first step toward developing a generic model for the acoustically radiating vibrational modes of the violin and related instruments, the modes of both freely supported and edge-constrained top and back plates have been investigated as functions of shape, arching height, elastic anisotropy, the f-holes and associated island area, thickness graduations, and the additional boundary constraints of the ribs, soundpost, and bass-bar present in the assembled instrument. Comsol shell structure finite element software has been used as a quasi-experimental tool, with physical and geometric properties varied smoothly, often over several orders of magnitude, allowing the development of the plate modes to be followed continuously from those of an initially square plate to those of doubly-arched, guitar-shaped, orthotropic plates and their dependence on all the above factors. PMID:25618046

  1. Positive battery plate

    NASA Technical Reports Server (NTRS)

    Rowlette, John R. (Inventor)

    1985-01-01

    The power characteristics of a lead acid battery are improved by incorporating a dispersion of 1 to 10% by weight of a thermodynamically stable conductivity additive, such as conductive tin oxide coated glass fibers (34) of filamentary glass wool (42) in the positive active layer (32) carried on the grid (30) of the positive plate (16). Positive plate potential must be kept high enough to prevent reduction of the tin oxide to tin by utilizing an oversized, precharged positive paste.

  2. Fractal multifiber microchannel plates

    NASA Technical Reports Server (NTRS)

    Cook, Lee M.; Feller, W. B.; Kenter, Almus T.; Chappell, Jon H.

    1992-01-01

    The construction and performance of microchannel plates (MCPs) made using fractal tiling mehtods are reviewed. MCPs with 40 mm active areas having near-perfect channel ordering were produced. These plates demonstrated electrical performance characteristics equivalent to conventionally constructed MCPs. These apparently are the first MCPs which have a sufficiently high degree of order to permit single channel addressability. Potential applications for these devices and the prospects for further development are discussed.

  3. Phononic plate waves.

    PubMed

    Wu, Tsung-Tsong; Hsu, Jin-Chen; Sun, Jia-Hong

    2011-10-01

    In the past two decades, phononic crystals (PCs) which consist of periodically arranged media have attracted considerable interest because of the existence of complete frequency band gaps and maneuverable band structures. Recently, Lamb waves in thin plates with PC structures have started to receive increasing attention for their potential applications in filters, resonators, and waveguides. This paper presents a review of recent works related to phononic plate waves which have recently been published by the authors and coworkers. Theoretical and experimental studies of Lamb waves in 2-D PC plate structures are covered. On the theoretical side, analyses of Lamb waves in 2-D PC plates using the plane wave expansion (PWE) method, finite-difference time-domain (FDTD) method, and finite-element (FE) method are addressed. These methods were applied to study the complete band gaps of Lamb waves, characteristics of the propagating and localized wave modes, and behavior of anomalous refraction, called negative refraction, in the PC plates. The theoretical analyses demonstrated the effects of PC-based negative refraction, lens, waveguides, and resonant cavities. We also discuss the influences of geometrical parameters on the guiding and resonance efficiency and on the frequencies of waveguide and cavity modes. On the experimental side, the design and fabrication of a silicon-based Lamb wave resonator which utilizes PC plates as reflective gratings to form the resonant cavity are discussed. The measured results showed significant improvement of the insertion losses and quality factors of the resonators when the PCs were applied. PMID:21989878

  4. Caribbean plate interactions

    SciTech Connect

    Ball, M. )

    1993-02-01

    Vector analysis of plate motions, derived from studies of Atlantic magnetic lineations and fracture zone trends, indicates the following relative movements between the Caribbean, North American, and South American Plates. (1) During Early Jurassic to Early Cretaceous, the North American Plate moved 1900 km westward and 900 km northward relative to the South American Plate. A broad zone including the Caribbean region, i.e., the zone between the North and South America Plates, was a site of left-lateral shear and north-south extension. (2) During Early Cretaceous to Late Cretaceous, the North American Mate moved an additional 1200 km westward relative to South America across this zone. (3) During Late Cretaceous to the end of the Eocene, the North American Plate moved 200 km westward and 400 km northward relative to the South American Plate. (4) From the end of the Eocene to near the end of the Miocene, North America converged on South America some 200 km and moved 100 km eastward relative to it. Through the Mesozoic and earliest Tertiary history of the Caribbean, the region was a shear zone within which left-lateral displacement exceeded 3000 km and north-south extension exceeded 1300 km. In regard to time, 80% of the history of the Caribbean region is one of north-south extension and left-lateral shear. In terms of space, 97% of the shear is left-lateral and the ratio of divergence versus convergence is 7 to 1. Thus, characterizing the Caribbean region, and the Atlantic to its east, as a zone of north-south extension and left-lateral shear, is a fair generalization.

  5. Using Plate Mapping to Examine Portion Size and Plate Composition for Large and Small Divided Plates

    PubMed Central

    Sharp, David E.; Sobal, Jeffery; Wansink, Brian

    2015-01-01

    Does the size of a plate influence the serving of all items equally, or does it influence the serving of some foods – such as meat versus starch versus vegetables – very differently? To examine this, we utilize a promising new plate mapping method where people drew a meal on a paper plate to examine sensitivity to small versus large three-compartment divided plates in portion size and meal composition in a sample of 109 university students. The total drawn meal area was 37% bigger on large plates than small plates, that is, the portion of plate coverage did not differ by plate size. Men and women drew bigger vegetable portions and men drew bigger meat portions on large plates when compared to small plates. These results suggest that men and women are differentially sensitive to plate size for overall meal size and for meal composition. Implications for decreasing portion size and improving meal balance are discussed. PMID:25280373

  6. Cadmium plating replacements

    SciTech Connect

    Nelson, M.J.; Groshart, E.C.

    1995-03-01

    The Boeing Company has been searching for replacements to cadmium plate. Two alloy plating systems seem close to meeting the needs of a cadmium replacement. The two alloys, zinc-nickel and tin-zinc are from alloy plating baths; both baths are neutral pH. The alloys meet the requirements for salt fog corrosion resistance, and both alloys excel as a paint base. Currently, tests are being performed on standard fasteners to compare zinc-nickel and tin-zinc on threaded hardware where cadmium is heavily used. The Hydrogen embrittlement propensity of the zinc-nickel bath has been tested, and just beginning for the tin-zinc bath. Another area of interest is the electrical properties on aluminum for tin-zinc and will be discussed. The zinc-nickel alloy plating bath is in production in Boeing Commercial Airplane Group for non-critical low strength steels. The outlook is promising that these two coatings will help The Boeing Company significantly reduce its dependence on cadmium plating.

  7. Cadmium plating replacements

    NASA Technical Reports Server (NTRS)

    Nelson, Mary J.; Groshart, Earl C.

    1995-01-01

    The Boeing Company has been searching for replacements to cadmium plate. Two alloy plating systems seem close to meeting the needs of a cadmium replacement. The two alloys, zinc-nickel and tin-zinc are from alloy plating baths; both baths are neutral pH. The alloys meet the requirements for salt fog corrosion resistance, and both alloys excel as a paint base. Currently, tests are being performed on standard fasteners to compare zinc-nickel and tin-zinc on threaded hardware where cadmium is heavily used. The Hydrogen embrittlement propensity of the zinc-nickel bath has been tested, and just beginning for the tin-zinc bath. Another area of interest is the electrical properties on aluminum for tin-zinc and will be discussed. The zinc-nickel alloy plating bath is in production in Boeing Commercial Airplane Group for non-critical low strength steels. The outlook is promising that these two coatings will help The Boeing Company significantly reduce its dependence on cadmium plating.

  8. Bipolar battery plate

    NASA Technical Reports Server (NTRS)

    Rowlette, John J. (Inventor)

    1987-01-01

    A liquid-impermeable plate (10) having through-plate conductivity with essentially zero resistance comprises an insulator sheet (12) having a series of spaced perforations (14) each of which contains a metal element (16) sealingly received into the perforation (14). A low-cost plate can readily be manufactured by punching a thermoplastic sheet (40) such as polypropylene with a punching tool (52), filling the apertures with led spheres (63) having a diameter smaller than the holes (50) but larger than the thickness of the sheet, sweeping excess spheres (62) off the sheet with a doctor blade (60) and then pressing a heated platen (74) onto the sheet to swage the spheres into a cylindrical shape and melt the surrounding resin to form a liquid-impermeable collar (4) sealing the metal into the sheet.

  9. Enzyme activity deviates due to spatial and temporal temperature profiles in commercial microtiter plate readers.

    PubMed

    Grosch, Jan-Hendrik; Sieben, Michaela; Lattermann, Clemens; Kauffmann, Kira; Büchs, Jochen; Spieß, Antje C

    2016-03-01

    Microtiter plates (MTP) and automatized techniques are increasingly applied in the field of biotechnology. However, the susceptibility of MTPs to edge effects such as thermal gradients can lead to high variation of measured enzyme activities. In an effort to enhance experimental reliability, to quantify, and to minimize instrument-caused deviations in enzyme kinetics between two MTP-readers, we comprehensively quantified temperature distribution in 96-well MTPs. We demonstrated the robust application of the absorbance dye cresol red as easily applicable temperature indicator in cuvettes and MTPs and determined its accuracy to ±0.16°C. We then quantified temperature distributions in 96-well MTPs revealing temperature deviations over single MTP of up to 2.2°C and different patterns in two commercial devices (BioTek Synergy 4 and Synergy Mx). The obtained liquid temperature was shown to be substantially controlled by evaporation. The temperature-induced enzyme activity variation within MTPs amounted to about 20 %. Activity deviations between MTPs and to those in cuvettes were determined to 40 % due to deviations from the set temperature in MTPs. In conclusion, we propose a better control of experimental conditions in MTPs or alternative experimental systems for reliable determination of kinetic parameters for bioprocess development. PMID:26709721

  10. Nitrided Metallic Bipolar Plates

    SciTech Connect

    Brady, Michael P; Tortorelli, Peter F; Pihl, Josh A; Toops, Todd J; More, Karren Leslie; Meyer III, Harry M; Vitek, John Michael; Wang, Heli; Turner, John; Wilson, Mahlon; Garzon, Fernando; Rockward, Tommy; Connors, Dan; Rakowski, Jim; Gervasio, Don

    2008-01-01

    The objectives are: (1) Develop and optimize stainless steel alloys amenable to formation of a protective Cr-nitride surface by gas nitridation, at a sufficiently low cost to meet DOE targets and with sufficient ductility to permit manufacture by stamping. (2) Demonstrate capability of nitridation to yield high-quality stainless steel bipolar plates from thin stamped alloy foils (no significant stamped foil warping or embrittlement). (3) Demonstrate single-cell fuel cell performance of stamped and nitrided alloy foils equivalent to that of machined graphite plates of the same flow-field design ({approx}750-1,000 h, cyclic conditions, to include quantification of metal ion contamination of the membrane electrode assembly [MEA] and contact resistance increase attributable to the bipolar plates). (4) Demonstrate potential for adoption in automotive fuel cell stacks. Thin stamped metallic bipolar plates offer the potential for (1) significantly lower cost than currently-used machined graphite bipolar plates, (2) reduced weight/volume, and (3) better performance and amenability to high volume manufacture than developmental polymer/carbon fiber and graphite composite bipolar plates. However, most metals exhibit inadequate corrosion resistance in proton exchange membrane fuel cell (PEMFC) environments. This behavior leads to high electrical resistance due to the formation of surface oxides and/or contamination of the MEA by metallic ions, both of which can significantly degrade fuel cell performance. Metal nitrides offer electrical conductivities up to an order of magnitude greater than that of graphite and are highly corrosion resistant. Unfortunately, most conventional coating methods (for metal nitrides) are too expensive for PEMFC stack commercialization or tend to leave pinhole defects, which result in accelerated local corrosion and unacceptable performance.

  11. Plate-mantle coupling from post-Pangea plate kinematics

    NASA Astrophysics Data System (ADS)

    Zahirovic, Sabin; Dietmar Müller, R.; Seton, Maria; Flament, Nicolas

    2015-04-01

    Convection in the Earth's mantle that involves plates at the surfaces gives rise to plate velocities that vary through time and depend on the balance of plate boundary forces, with the present-day providing a snapshot of this ongoing process. However, present-day plate velocities do not capture plate behaviour over geologically representative timeframes and thus cannot be used to evaluate factors limiting plate velocities. Previous studies investigated the effects of continental keels on plate speeds by either using the present-day snapshot or a limited number of reconstructed plate configurations, often leading to conflicting results. For example, an early assumption was that continental keels (especially cratons) were unlikely to impede fast plate motions because India's velocity approached ~20 cm/yr in the Eocene prior to the collision with Eurasia. We employ a modern plate reconstruction approach with evolving global topological plate boundaries for the post-Pangea timeframe (since 200 Ma) to evaluate factors controlling plate velocities. Plate boundary configurations and plate velocities are extracted from the open-source and cross-platform plate reconstruction package GPlates (www.gplates.org) at 1 Myr intervals. For each plate, at each timestep, the area of continental and cratonic lithosphere is calculated to evaluate the effect on plate velocities. Our results support that oceanic plates tend to be 2-3 times faster than plates with large portion of continental plate area, consistent with predictions of numerical models of mantle convection. The fastest plates (~8.5 cm/yr RMS) are dominated by oceanic plate area and high subducting portion of plate perimeter, while the slowest plates (~2.6-2.8 cm/yr RMS) are dominated by continental plate area and bounded by transforms and mid-oceanic ridge segments. Importantly, increasing cratonic fractions (both Proterozoic and Archean lithosphere) significantly impede plate velocities, suggesting that deep continental

  12. Reduced Plating Ignitron

    NASA Technical Reports Server (NTRS)

    Polzin, Kurt A (Inventor); Pearson, J Boise (Inventor)

    2014-01-01

    An ignitron apparatus has an airtight tubular housing having a first sealed end and a second sealed end. An anode is connected at the first sealed end, projecting into the housing, and a recess at the second sealed and forms a well which contains a quantity of liquid gallium or gallium alloy making up the cathode. An ignitor projects through the liquid metal and into the housing. The inner surface of the housing includes at least one plating-reduction structure to prevent electrical shorting of the apparatus caused by plating of the liquid metal.

  13. NICKEL PLATING PROCESS

    DOEpatents

    Hoover, T.B.; Zava, T.E.

    1959-05-12

    A simplified process is presented for plating nickel by the vapor decomposition of nickel carbonyl. In a preferred form of the invention a solid surface is nickel plated by subjecting the surface to contact with a mixture containing by volume approximately 20% nickel carbonyl vapor, 2% hydrogen sulfide and .l% water vapor or 1% oxygen and the remainder carbon dioxide at room temperature until the desired thickness of nickel is obtained. The advantage of this composition over others is that the normally explosive nickel carbonyl is greatly stabilized.

  14. Nuclear reactor alignment plate configuration

    DOEpatents

    Altman, David A; Forsyth, David R; Smith, Richard E; Singleton, Norman R

    2014-01-28

    An alignment plate that is attached to a core barrel of a pressurized water reactor and fits within slots within a top plate of a lower core shroud and upper core plate to maintain lateral alignment of the reactor internals. The alignment plate is connected to the core barrel through two vertically-spaced dowel pins that extend from the outside surface of the core barrel through a reinforcement pad and into corresponding holes in the alignment plate. Additionally, threaded fasteners are inserted around the perimeter of the reinforcement pad and into the alignment plate to further secure the alignment plate to the core barrel. A fillet weld also is deposited around the perimeter of the reinforcement pad. To accomodate thermal growth between the alignment plate and the core barrel, a gap is left above, below and at both sides of one of the dowel pins in the alignment plate holes through with the dowel pins pass.

  15. Growth Plate Injuries

    MedlinePlus

    ... or crushed, the growth plate may close prematurely, forming a bony bridge or “bar.” The risk of ... this publication: James S. Panagis, M.D., M.P.H., NIAMS/NIH; R. Tracy Ballock, M.D., Case ...

  16. The Plate Tectonics Project

    ERIC Educational Resources Information Center

    Hein, Annamae J.

    2011-01-01

    The Plate Tectonics Project is a multiday, inquiry-based unit that facilitates students as self-motivated learners. Reliable Web sites are offered to assist with lessons, and a summative rubric is used to facilitate the holistic nature of the project. After each topic (parts of the Earth, continental drift, etc.) is covered, the students will…

  17. INL HIP Plate Fabrication

    SciTech Connect

    B. H. Park; C. R. Clark; J. F. Jue

    2010-02-01

    This document outlines the process used to bond monolithic fuel plates by Hot Isostatic Pressing (HIP). This method was developed at Idaho National Laboratory (INL) for the Reduced Enrichment for Research and Test Reactors (RERTR) program. These foils have been used in a number of irradiation experiments in support of the United States Global Threat Reduction Initiative (GTRI) program.

  18. Unitary plate electrode

    NASA Technical Reports Server (NTRS)

    Rowlette, John J. (Inventor); Clough, Thomas J. (Inventor); Josefowicz, Jack Y. (Inventor); Sibert, John W. (Inventor)

    1985-01-01

    The unitary electrode (10) comprises a porous sheet (12) of fiberglass the strands (14) of which contain a coating (16) of conductive tin oxide. The lower portion of the sheet contains a layer (18) of resin and the upper layer (20) contains lead dioxide forming a positive active electrode on an electrolyte-impervious layer. The strands (14) form a continuous conduction path through both layers (16, 18). Tin oxide is prevented from reduction by coating the surface of the plate facing the negative electrode with a conductive, impervious layer resistant to reduction such as a thin film (130) of lead or graphite filled resin adhered to the plate with a layer (31) of conductive adhesive. The plate (10) can be formed by casting a molten resin from kettle (60) onto a sheet of glass wool (56) overlying a sheet of lead foil and then applying positive active paste from hopper (64) into the upper layer (68). The plate can also be formed by passing an assembly of a sheet ( 80) of resin, a sheet (86) of sintered glass and a sheet (90) of lead between the nip (92) of heated rollers (93, 95) and then filling lead oxide into the pores (116) of the upper layer (118).

  19. Optimizing Two-Color Semiconductor Nanocrystal Immunoassays in Single Well Microtiter Plate Formats

    PubMed Central

    Sapsford, Kim E.; Spindel, Samantha; Jennings, Travis; Tao, Guoliang; Triulzi, Robert C.; Algar, W. Russ; Medintz, Igor L.

    2011-01-01

    The simultaneous detection of two analytes, chicken IgY (IgG) and Staphylococcal enterotoxin B (SEB), in the single well of a 96-well plate is demonstrated using luminescent semiconductor quantum dot nanocrystal (NC) tracers. The NC-labeled antibodies were prepared via sulfhydryl-reactive chemistry using a facile protocol that took <3 h. Dose response curves for each target were evaluated in a single immunoassay format and compared to Cy5, a fluorophore commonly used in fluorescent immunoassays, and found to be equivalent. Immunoassays were then performed in a duplex format, demonstrating multiplex detection in a single well with limits of detection equivalent to the single assay format: 9.8 ng/mL chicken IgG and 7.8 ng/mL SEB. PMID:22164051

  20. Renewable liquid reflecting zone plate

    DOEpatents

    Toor, Arthur; Ryutov, Dmitri D.

    2003-12-09

    A renewable liquid reflecting zone plate. Electrodes are operatively connected to a dielectric liquid in a circular or other arrangement to produce a reflecting zone plate. A system for renewing the liquid uses a penetrable substrate.

  1. MyPlate Food Guide

    MedlinePlus

    ... follow throughout your life. 2. Fruits Like veggies, fruits contain vitamins, minerals, and fiber. The red section of MyPlate is slightly smaller than the green, but together fruits and veggies should fill half your plate. Whole ...

  2. What Are Growth Plate Injuries?

    MedlinePlus

    ... activities. Other reasons for growth plate injuries are:  Child abuse  Injury from extreme cold (for example, frostbite)  Radiation ( ... problems) treats most growth plate injuries. At other times, the child will see a pediatric orthopaedic surgeon (a doctor ...

  3. What Are Growth Plate Injuries?

    MedlinePlus

    ... activities. Other reasons for growth plate injuries are: Child abuse Injury from extreme cold (for example, frostbite) Radiation ( ... problems) treats most growth plate injuries. At other times, the child will see a pediatric orthopaedic surgeon (a doctor ...

  4. Microchannel plate streak camera

    DOEpatents

    Wang, Ching L.

    1989-01-01

    An improved streak camera in which a microchannel plate electron multiplier is used in place of or in combination with the photocathode used in prior streak cameras. The improved streak camera is far more sensitive to photons (UV to gamma-rays) than the conventional x-ray streak camera which uses a photocathode. The improved streak camera offers gamma-ray detection with high temporal resolution. It also offers low-energy x-ray detection without attenuation inside the cathode. Using the microchannel plate in the improved camera has resulted in a time resolution of about 150 ps, and has provided a sensitivity sufficient for 1000 KeV x-rays.

  5. North American plate dynamics

    NASA Technical Reports Server (NTRS)

    Richardson, Randall M.; Reding, Lynn M.

    1991-01-01

    Deformation within the North American plate in response to various tectonic processes is modeled using an elastic finite element analysis. The tectonic processes considered in the modeling include ridge forces associated with the normal thermal evolution of oceanic lithosphere, shear and normal stresses transmitted across transforms, normal stresses transmitted across convergent boundaries, stresses due to horizontal density contrasts within the continent, and shear tractions applied along the base of the plate. Model stresses are calculated with respect to a lithostatic reference stress state. Shear stresses transmitted across transform boundaries along the San Andreas and Caribbean are small, of the order of 5-10 MPa. Also, compressive stresses of the order of 5-10 MPa transmitted across the major transforms improve the fit to the data. Compressive stresses across convergent margins along the Aleutians and the Middle America trench are important.

  6. Microchannel plate streak camera

    DOEpatents

    Wang, C.L.

    1989-03-21

    An improved streak camera in which a microchannel plate electron multiplier is used in place of or in combination with the photocathode used in prior streak cameras is disclosed. The improved streak camera is far more sensitive to photons (UV to gamma-rays) than the conventional x-ray streak camera which uses a photocathode. The improved streak camera offers gamma-ray detection with high temporal resolution. It also offers low-energy x-ray detection without attenuation inside the cathode. Using the microchannel plate in the improved camera has resulted in a time resolution of about 150 ps, and has provided a sensitivity sufficient for 1,000 KeV x-rays. 3 figs.

  7. Microchannel plate streak camera

    DOEpatents

    Wang, C.L.

    1984-09-28

    An improved streak camera in which a microchannel plate electron multiplier is used in place of or in combination with the photocathode used in prior streak cameras. The improved streak camera is far more sensitive to photons (uv to gamma-rays) than the conventional x-ray streak camera which uses a photocathode. The improved streak camera offers gamma-ray detection with high temporal resolution. It also offers low-energy x-ray detection without attenuation inside the cathode. Using the microchannel plate in the improved camera has resulted in a time resolution of about 150 ps, and has provided a sensitivity sufficient for 1000 keV x-rays.

  8. Bipolar battery plate

    NASA Technical Reports Server (NTRS)

    Rowlette, John J. (Inventor)

    1985-01-01

    A liquid-impermeable plate (10) having throughplate conductivity with essentially zero resistance comprises an insulator sheet (12) having a series of spaced perforations (14) each of which contains a metal element (16) sealingly received into the perforation (14). A low-cost plate can readily be manufactured by punching a thermoplastic sheet (40) such as polypropylene with a punching tool (52), filling the apertures with lead spheres (63) having a diameter smaller than the holes (50) but larger than the thickness of the sheet, sweeping excess spheres (62) off the sheet with a doctor blade (60) and then pressing a heated platen (74) onto the sheet to swage the spheres into a cylindrical shape and melt the surrounding resin to form a liquid-impermeable collar (4) sealing the metal into the sheet.

  9. Plate motion and deformation

    SciTech Connect

    Minster, B.; Prescott, W.; Royden, L.

    1991-02-01

    Our goal is to understand the motions of the plates, the deformation along their boundaries and within their interiors, and the processes that control these tectonic phenomena. In the broadest terms, we must strive to understand the relationships of regional and local deformation to flow in the upper mantle and the rheological, thermal and density structure of the lithosphere. The essential data sets which we require to reach our goal consist of maps of current strain rates at the earth's surface and the distribution of integrated deformation through time as recorded in the geologic record. Our success will depend on the effective synthesis of crustal kinematics with a variety of other geological and geophysical data, within a quantitative theoretical framework describing processes in the earth's interior. Only in this way can we relate the snapshot of current motions and earth structure provided by geodetic and geophysical data with long-term processes operating on the time scales relevant to most geological processes. The wide-spread use of space-based techniques, coupled with traditional geological and geophysical data, promises a revolution in our understanding of the kinematics and dynamics of plate motions over a broad range of spatial and temporal scales and in a variety of geologic settings. The space-based techniques that best address problems in plate motion and deformation are precise space-geodetic positioning -- on land and on the seafloor -- and satellite acquisition of detailed altimetric and remote sensing data in oceanic and continental areas. The overall science objectives for the NASA Solid Earth Science plan for the 1990's, are to Understand the motion and deformation of the lithosphere within and across plate boundaries'', and to understand the dynamics of the mantle, the structure and evolution of the lithosphere, and the landforms that result from local and regional deformation. 57 refs., 7 figs., 2 tabs.

  10. Smov FOS Plate Scale

    NASA Astrophysics Data System (ADS)

    Kinney, Anne

    1994-01-01

    The goal is to measure the precise plate scale and orientation. This will be acheived by performing a raster step and dwell sequence in the 4.3 arcsec aperture. The edges of the aperture should be avoided to prevent vignetting effects. An aperture map is required at each step of the dwell sequence. This test has to be conducted for both the RED and BLUE detectors. We will also determine the offset between the two detectors.

  11. Plated wire memory subsystem

    NASA Technical Reports Server (NTRS)

    Reynolds, L.; Tweed, H.

    1972-01-01

    The work performed entailed the design, development, construction and testing of a 4000 word by 18 bit random access, NDRO plated wire memory for use in conjunction with a spacecraft imput/output unit and central processing unit. The primary design parameters, in order of importance, were high reliability, low power, volume and weight. A single memory unit, referred to as a qualification model, was delivered.

  12. Martian plate tectonics

    NASA Astrophysics Data System (ADS)

    Sleep, N. H.

    1994-03-01

    The northern lowlands of Mars have been produced by plate tectonics. Preexisting old thick highland crust was subducted, while seafloor spreading produced thin lowland crust during late Noachian and Early Hesperian time. In the preferred reconstruction, a breakup margin extended north of Cimmeria Terra between Daedalia Planum and Isidis Planitia where the highland-lowland transition is relatively simple. South dipping subduction occured beneath Arabia Terra and east dipping subduction beneath Tharsis Montes and Tempe Terra. Lineations associated with Gordii Dorsum are attributed to ridge-parallel structures, while Phelegra Montes and Scandia Colles are interpreted as transfer-parallel structures or ridge-fault-fault triple junction tracks. Other than for these few features, there is little topographic roughness in the lowlands. Seafloor spreading, if it occurred, must have been relatively rapid. Quantitative estimates of spreading rate are obtained by considering the physics of seafloor spreading in the lower (approx. 0.4 g) gravity of Mars, the absence of vertical scarps from age differences across fracture zones, and the smooth axial topography. Crustal thickness at a given potential temperature in the mantle source region scales inversely with gravity. Thus, the velocity of the rough-smooth transition for axial topography also scales inversely with gravity. Plate reorganizations where young crust becomes difficult to subduct are another constraint on spreading age. Plate tectonics, if it occurred, dominated the thermal and stress history of the planet. A geochemical implication is that the lower gravity of Mars allows deeper hydrothermal circulation through cracks and hence more hydration of oceanic crust so that more water is easily subducted than on the Earth. Age and structural relationships from photogeology as well as median wavelength gravity anomalies across the now dead breakup and subduction margins are the data most likely to test and modify hypotheses

  13. Elastic plate spallation

    NASA Technical Reports Server (NTRS)

    Oline, L.; Medaglia, J.

    1972-01-01

    The dynamic finite element method was used to investigate elastic stress waves in a plate. Strain displacement and stress strain relations are discussed along with the stiffness and mass matrix. The results of studying point load, and distributed load over small, intermediate, and large radii are reported. The derivation of finite element matrices, and the derivation of lumped and consistent matrices for one dimensional problems with Laplace transfer solutions are included. The computer program JMMSPALL is also included.

  14. Plates with Incompatible Prestrain

    NASA Astrophysics Data System (ADS)

    Bhattacharya, Kaushik; Lewicka, Marta; Schäffner, Mathias

    2016-07-01

    We study effective elastic behavior of the incompatibly prestrained thin plates, where the prestrain is independent of thickness and uniform through the plate's thickness h. We model such plates as three-dimensional elastic bodies with a prescribed pointwise stress-free state characterized by a Riemannian metric G, and seek the limiting behavior as {h to 0}. We first establish that when the energy per volume scales as the second power of h, the resulting {Γ} -limit is a Kirchhoff-type bending theory. We then show the somewhat surprising result that there exist non-immersible metrics G for whom the infimum energy (per volume) scales smaller than h 2. This implies that the minimizing sequence of deformations carries nontrivial residual three-dimensional energy but it has zero bending energy as seen from the limit Kirchhoff theory perspective. Another implication is that other asymptotic scenarios are valid in appropriate smaller scaling regimes of energy. We characterize the metrics G with the above property, showing that the zero bending energy in the Kirchhoff limit occurs if and only if the Riemann curvatures R 1213, R 1223 and R 1212 of G vanish identically. We illustrate our findings with examples; of particular interest is an example where {G_{2 × 2}}, the two-dimensional restriction of G, is flat but the plate still exhibits the energy scaling of the Föppl-von Kármán type. Finally, we apply these results to a model of nematic glass, including a characterization of the condition when the metric is immersible, for {G = Id3 + γ n ⊗ n} given in terms of the inhomogeneous unit director field distribution { n in R^3}.

  15. Origin of Small Tectonic Plates

    NASA Astrophysics Data System (ADS)

    Mallard, C.; Coltice, N.; Seton, M.; Müller, D.; Tackley, P.

    2015-12-01

    The plate tectonic theory allowed to split the Earth surface into 6 (Le Pichon 1968) to 52 tectonic plates (Bird 2003). These plates are separated into two groups: the first of 7 large plates and the second of numerous smaller plates (Morra et al 2013). Previous studies using the reconstruction of the past 200 My, suggest that the size of large plates is driven by mantle flow. But the tools employed are descriptive (Morra et al 2013, Sornette and Pisarenko 2003), hence ignoring forces and physical principles within the lithosphere and the mantle. The processes at the origin of small plates remain unknown. We developed a new approach to explain the plate sizes. We demonstrate that the physics of convection drives it. We applied plate tectonics theory on 3D spherical convection models generating plate-like motions, which give access to a complete survey of data: velocities, viscosity and heat flow. Our data show that (1) the large plates depend on the dominating scale of the convective flow due to the initiation or the shutdown of subductions; (2) the smaller plates are generated thanks to large variability of regional stresses along subduction zone by slab pull and suction influenced by the geometry of trenches. Our results are consistent with the quick reorganizations of back-arc basins occuring synchronously with the modification of subduction zones geometry around the Pacific plate (Sdrolias et al 2004). Hence, we conclude that (1) the decreasing number of small plates in the plate reconstructions back in time is an artifact induced by their short lifetime, that is why they are artificially ignored; (2) the geometry of past trenches is simplified leading to an underestimation of the length of subduction zones.

  16. Plate tectonics conserves angular momentum

    NASA Astrophysics Data System (ADS)

    Bowin, C.

    2009-03-01

    A new combined understanding of plate tectonics, Earth internal structure, and the role of impulse in deformation of the Earth's crust is presented. Plate accelerations and decelerations have been revealed by iterative filtering of the quaternion history for the Euler poles that define absolute plate motion history for the past 68 million years, and provide an unprecedented precision for plate angular rotation variations with time at 2-million year intervals. Stage poles represent the angular rotation of a plate's motion between adjacent Euler poles, and from which the maximum velocity vector for a plate can be determined. The consistent maximum velocity variations, in turn, yield consistent estimates of plate accelerations and decelerations. The fact that the Pacific plate was shown to accelerate and decelerate, implied that conservation of plate tectonic angular momentum must be globally conserved, and that is confirmed by the results shown here (total angular momentum ~1.4 E+27 kgm2s-1). Accordingly, if a plate decelerates, other plates must increase their angular momentums to compensate. In addition, the azimuth of the maximum velocity vectors yields clues as to why the "bend" in the Emperor-Hawaiian seamount trend occurred near 46 Myr. This report summarizes processing results for 12 of the 14 major tectonic plates of the Earth (except for the Juan de Fuca and Philippine plates). Plate accelerations support the contention that plate tectonics is a product of torques that most likely are sustained by the sinking of positive density anomalies due to phase changes in subducted gabbroic lithosphere at depth in the upper lower mantle (above 1200 km depth). The tectonic plates are pulled along by the sinking of these positive mass anomalies, rather than moving at near constant velocity on the crests of convection cells driven by rising heat. These results imply that spreading centers are primarily passive reactive features, and fracture zones (and wedge-shaped sites

  17. Symmetries in laminated composite plates

    NASA Technical Reports Server (NTRS)

    Noor, A. K.

    1976-01-01

    The different types of symmetry exhibited by laminated anisotropic fibrous composite plates are identified and contrasted with the symmetries of isotropic and homogeneous orthotropic plates. The effects of variations in the fiber orientation and the stacking sequence of the layers on the symmetries exhibited by composite plates are discussed. Both the linear and geometrically nonlinear responses of the plates are considered. A simple procedure is presented for exploiting the symmetries in the finite element analysis. Examples are given of square, skew and polygonal plates where use of symmetry concepts can significantly reduce the scope and cost of analysis.

  18. Fuel cell end plate structure

    DOEpatents

    Guthrie, Robin J.; Katz, Murray; Schroll, Craig R.

    1991-04-23

    The end plates (16) of a fuel cell stack (12) are formed of a thin membrane. Pressure plates (20) exert compressive load through insulation layers (22, 26) to the membrane. Electrical contact between the end plates (16) and electrodes (50, 58) is maintained without deleterious making and breaking of electrical contacts during thermal transients. The thin end plate (16) under compressive load will not distort with a temperature difference across its thickness. Pressure plate (20) experiences a low thermal transient because it is insulated from the cell. The impact on the end plate of any slight deflection created in the pressure plate by temperature difference is minimized by the resilient pressure pad, in the form of insulation, therebetween.

  19. A titer plate-based polymer microfluidic platform for high throughput nucleic acid purification.

    PubMed

    Park, D S-W; Hupert, M L; Witek, M A; You, B H; Datta, P; Guy, J; Lee, J-B; Soper, S A; Nikitopoulos, D E; Murphy, M C

    2008-02-01

    A 96-well solid-phase reversible immobilization (SPRI) reactor plate was designed to demonstrate functional titer plate-based microfluidic platforms. Nickel, large area mold inserts were fabricated using an SU-8 based, UV-LIGA technique on 150 mm diameter silicon substrates. Prior to UV exposure, the prebaked SU-8 resist was flycut to reduce the total thickness variation to less than 5 mum. Excellent UV lithography results, with highly vertical sidewalls, were obtained in the SU-8 by using an UV filter to remove high absorbance wavelengths below 350 nm. Overplating of nickel in the SU-8 patterns produced high quality, high precision, metal mold inserts, which were used to replicate titer plate-based SPRI reactors using hot embossing of polycarbonate (PC). Optimized molding conditions yielded good feature replication fidelity and feature location integrity over the entire surface area. Thermal fusion bonding of the molded PC chips at 150 degrees C resulted in leak-free sealing, which was verified in leakage tests using a fluorescent dye. The assembled SPRI reactor was used for simple, fast purification of genomic DNA from whole cell lysates of several bacterial species, which was verified by PCR amplification of the purified genomic DNA. PMID:17659445

  20. Optimization of Salmonella Typhi biofilm assay on polypropylene microtiter plates using response surface methodology.

    PubMed

    Ganjali Dashti, M; Abdeshahian, P; Sudesh, K; Phua, K K

    2016-04-01

    The objective of this study was to develop an optimized assay for Salmonella Typhi biofilm that mimics the environment of the gallbladder as an experimental model for chronic typhoid fever. Multi-factorial assays are difficult to optimize using traditional one-factor-at-a-time optimization methods. Response surface methodology (RSM) was used to optimize six key variables involved in S. Typhi biofilm formation on cholesterol-coated polypropylene 96-well microtiter plates. The results showed that bile (1.22%), glucose (2%), cholesterol (0.05%) and potassium chloride (0.25%) were critical factors affecting the amount of biofilm produced, but agitation (275 rpm) and sodium chloride (0.5%) had antagonistic effects on each other. Under these optimum conditions the maximum OD reading for biofilm formation was 3.4 (λ600 nm), and the coefficients of variation for intra-plate and inter-plate assays were 3% (n = 20) and 5% (n = 8), respectively. These results showed that RSM is an effective approach for biofilm assay optimization. PMID:26963754

  1. Wobble plate engine

    SciTech Connect

    Derderian, H.; Pronovost, J.

    1980-07-01

    A description is given of a conventional Stirling cycle engine of the type characterized by an elongated cylinder having a closed end and an open end, means for applying heat to the exterior of the cylinder to heat gas in the interior of the cylinder at the closed end thereof, a displacer piston mounted for a reciprocation within the closed end of the cylinder and a power piston axially aligned with the displacer piston and mounted for coaxial reciprocation between the displacer piston and the open end of the cylinder, the reciprocation of the displacer piston leading the corresponding stroke of the power piston by a predetermined phase angle, the improved means for properly phasing the reciprocation of the two pistons and for converting the reciprocation of the power piston into rotation of an output shaft which is parallel to the axis of reciprocation comprising: a supporting frame; an output shaft mounted on said frame for rotation about a first axis which is parallel to the axis of reciprocation of the two pistons, said shaft having an inclined cylindrical bearing surface the axis of which intersects said first axis at an acute angle; gimbal means pivotally mounted on said supporting frame for oscillation about a second axis perpendicular to and intersecting first axis; a wobble plate pivotally mounted on a third axis within said gimbal means for oscillation with said gimbal means and for further oscillation about said third axis which is mutually perpendicular to and intersecting said first and second axes, said wobble plate being rotatably mounted on said inclined cylindrical bearing surface in a plane which is perpendicular to said axis of said bearing surface whereby said output shaft can rotate about said first axis as said wobble plate oscillates about said second and third axes.

  2. Shuttle plate braiding machine

    NASA Technical Reports Server (NTRS)

    Huey, Jr., Cecil O. (Inventor)

    1994-01-01

    A method and apparatus for moving yarn in a selected pattern to form a braided article. The apparatus includes a segmented grid of stationary support elements and a plurality of shuttles configured to carry yarn. The shuttles are supported for movement on the grid assembly and each shuttle includes a retractable plunger for engaging a reciprocating shuttle plate that moves below the grid assembly. Such engagement at selected times causes the shuttles to move about the grid assembly in a selected pattern to form a braided article of a particular geometry.

  3. Reduced hydrogen cadmium plating

    SciTech Connect

    Hoeller, T.; Ross, L. ); Varma, R. ); Agarwala, V.S. )

    1991-01-01

    This paper demonstrates the advantages of using a periodic reverse pulse plating method, incorporating a fast cathodic pulse which is separated from the subsequent anodic/cathodic pulses by a long rest period in producing silvery cadmium coatings on steel from aqueous fluoroborate electrolyte. Also, the deposition obtained by combination of pulse currents and turbulent electrolyte flow system (forced convection of electrolyte, Re {approximately} 20-25,000) result in a near hydrogen-free electrodeposition of fine- grained cadmium. This is confirmed by the determination of diffusible hydrogen by the electrochemical (Barnach Electrode) method.

  4. Plated wire memory subsystem

    NASA Technical Reports Server (NTRS)

    Carpenter, K. H.

    1974-01-01

    The design, construction, and test history of a 4096 word by 18 bit random access NDRO Plated Wire Memory for use in conjunction with a spacecraft input/output and central processing unit is reported. A technical and functional description is given along with diagrams illustrating layout and systems operation. Test data is shown on the procedures and results of system level and memory stack testing, and hybrid circuit screening. A comparison of the most significant physical and performance characteristics of the memory unit versus the specified requirements is also included.

  5. Ultrafast microchannel plate photomultipliers.

    PubMed

    Kume, H; Koyama, K; Nakatsugawa, K; Suzuki, S; Fatlowitz, D

    1988-03-15

    Performance characteristics of several new types of photomultiplier tubes (PMT) with microchannel plates (MCP) are presented in this paper. They are the MCP-PMT with 6-microm diam channels, MCP-PMT with an S-l photocathode, and MCP-PMT with multi (discrete) anode and gatable MCP-PMT. Important requirements of an optical detector for picosecond lasers, fluorescence measurements, and material analysis are low light detectability, ultrafast time response, and versatile operation including modulation. The basic configuration, characteristics, and practical results of these detectors are described. PMID:20531532

  6. Tectonics of the Easter plate

    NASA Technical Reports Server (NTRS)

    Engeln, J. F.; Stein, S.

    1984-01-01

    A new model for the Easter plate is presented in which rift propagation has resulted in the formation of a rigid plate between the propagating and dying ridges. The distribution of earthquakes, eleven new focal mechanisms, and existing bathymetric and magnetic data are used to describe the tectonics of this area. Both the Easter-Nazca and Easter-Pacific Euler poles are sufficiently close to the Easter plate to cause rapid changes in rates and directions of motion along the boundaries. The east and west boundaries are propagating and dying ridges; the southwest boundary is a slow-spreading ridge and the northern boundary is a complex zone of convergent and transform motion. The Easter plate may reflect the tectonics of rift propagation on a large scale, where rigid plate tectonics requires boundary reorientation. Simple schematic models to illustrate the general features and processes which occur at plates resulting from large-scale rift propagation are used.

  7. Localised Plate Motion on Venus

    NASA Astrophysics Data System (ADS)

    Ghail, R. C.

    1996-03-01

    The volcanic and tectonic features observed in Dali Vinculum, Parga Vinculum and Imdr Regio are concentrated at long, narrow, curvilinear zones, with relatively minor volcanism and tectonism between these zones. These zones, whilst more diffuse than terrestrial plate boundaries, nevertheless define the margins of tectonic plates. In contrast to Earth, however, it appears that venusian plates are neither created nor destroyed by lateral motion. Rather, plates are thinned and intruded at vincula plate boundaries, vertically accreted by small-scale intra-plate (planitia) volcanism and perhaps destroyed by delamination of thickened crust in tesserae and montane regions such as Thetis Regio and Ishtar Terra. The diversity in age both between and within these three areas together with the evidence for infrequent, small scale resurfacing in the planitiae are difficult to reconcile with a non-uniformitarian geological process.

  8. Multiple plate hydrostatic viscous damper

    SciTech Connect

    Ludwig, L.P.

    1981-02-01

    A device for damping radial motion of a rotating shaft is described. The damper comprises a series of spaced plates extending in a radial direction. A hydraulic piston is utilized to place a load in these plates. Each annular plate is provided with a suitable hydrostatic bearing geometry on at least one of its faces. This structure provides a high degree of dampening in a rotor case system of turbomachinery in general. The damper is particularly useful in gas turbine engines.

  9. Multiple plate hydrostatic viscous damper

    NASA Technical Reports Server (NTRS)

    Ludwig, L. P. (Inventor)

    1981-01-01

    A device for damping radial motion of a rotating shaft is described. The damper comprises a series of spaced plates extending in a radial direction. A hydraulic piston is utilized to place a load in these plates. Each annular plate is provided with a suitable hydrostatic bearing geometry on at least one of its faces. This structure provides a high degree of dampening in a rotor case system of turbomachinery in general. The damper is particularly useful in gas turbine engines.

  10. Channel plate for DNA sequencing

    DOEpatents

    Douthart, R.J.; Crowell, S.L.

    1998-01-13

    This invention is a channel plate that facilitates data compaction in DNA sequencing. The channel plate has a length, a width and a thickness, and further has a plurality of channels that are parallel. Each channel has a depth partially through the thickness of the channel plate. Additionally an interface edge permits electrical communication across an interface through a buffer to a deposition membrane surface. 15 figs.

  11. Ion plating for the future

    NASA Technical Reports Server (NTRS)

    Spalvins, T.

    1981-01-01

    The ion plating techniques are classified relative to the instrumental set up, evaporation media, and mode of transport. A distinction is drawn between the low vacuum (plasma) and high vacuum (ion beam) techniques. Ion plating technology is discussed at the fundamental and industrial level. At the fundamental level, the capabilities and limitations of the plasma (evaporant flux) and film characteristics are evaluated. And on the industrial level, the performance and potential uses of ion plated films are discussed.

  12. Channel plate for DNA sequencing

    DOEpatents

    Douthart, Richard J.; Crowell, Shannon L.

    1998-01-01

    This invention is a channel plate that facilitates data compaction in DNA sequencing. The channel plate has a length, a width and a thickness, and further has a plurality of channels that are parallel. Each channel has a depth partially through the thickness of the channel plate. Additionally an interface edge permits electrical communication across an interface through a buffer to a deposition membrane surface.

  13. Carbon-assisted flyer plates

    DOEpatents

    Stahl, David B.; Paisley, Dennis L.

    1994-01-01

    A laser driven flyer plate utilizing an optical fiber connected to a laser. The end of the optical fiber has a layer of carbon and a metal layer deposited onto it. The carbon layer provides the laser induced plasma which is superior to the plasma produced from most metals. The carbon layer plasma is capable of providing a flatter flyer plate, converting more of the laser energy to driving plasma, promoting a higher flyer plate acceleration, and providing a more uniform pulse behind the plate. In another embodiment, the laser is in optical communication with a substrate onto which a layer of carbon and a layer of metal have been deposited.

  14. True Shear Parallel Plate Viscometer

    NASA Technical Reports Server (NTRS)

    Ethridge, Edwin; Kaukler, William

    2010-01-01

    This viscometer (which can also be used as a rheometer) is designed for use with liquids over a large temperature range. The device consists of horizontally disposed, similarly sized, parallel plates with a precisely known gap. The lower plate is driven laterally with a motor to apply shear to the liquid in the gap. The upper plate is freely suspended from a double-arm pendulum with a sufficiently long radius to reduce height variations during the swing to negligible levels. A sensitive load cell measures the shear force applied by the liquid to the upper plate. Viscosity is measured by taking the ratio of shear stress to shear rate.

  15. Glass-bead peen plating

    NASA Technical Reports Server (NTRS)

    Graves, J. R.

    1974-01-01

    Peen plating of aluminum, copper, and nickel powders was investigated. Only aluminum was plated successfully within the range of peen plating conditions studied. Optimum plating conditions for aluminum were found to be: (1) bead/powder mixture containing 25 to 35% powder by weight, (2) peening intensity of 0.007A as measured by Almen strip, and (3) glass impact bead diameter of at least 297 microns (0.0117 inches) for depositing-100 mesh aluminum powder. No extensive cleaning or substrate preparation is required beyond removing loose dirt or heavy oil.

  16. Laser-driven flyer plate

    SciTech Connect

    Paisley, D.L.

    1991-09-10

    Disclosed is an apparatus for producing high velocity flyer plates involving placing a layer of dielectric material between a first metal foil and a second metal foil. With laser irradiation through an optical substrate, the first metal foil forms a plasma in the area of the irradiation, between the substrate and the solid portion of the first metal foil. When the pressure between the substrate and the foil reaches the stress limit of the dielectric, the dielectric will break away and launch the flyer plate out of the second metal foil. The mass of the flyer plate is controlled, as no portion of the flyer plate is transformed into a plasma. 2 figures.

  17. Laser-driven flyer plate

    DOEpatents

    Paisley, Dennis L.

    1991-01-01

    Apparatus for producing high velocity flyer plates involving placing a layer of dielectric material between a first metal foil and a second metal foil. With laser irradiation through an optical substrate, the first metal foil forms a plasma in the area of the irradiation, between the substrate and the solid portion of the first metal foil. When the pressure between the substrate and the foil reaches the stress limit of the dielectric, the dielectric will break away and launch the flyer plate out of the second metal foil. The mass of the flyer plate is controlled, as no portion of the flyer plate is transformed into a plasma.

  18. Scintillator plate calorimetry

    SciTech Connect

    Price, L.E.

    1990-01-01

    Calorimetry using scintillator plates or tiles alternated with sheets of (usually heavy) passive absorber has been proven over multiple generations of collider detectors. Recent detectors including UA1, CDF, and ZEUS have shown good results from such calorimeters. The advantages offered by scintillator calorimetry for the SSC environment, in particular, are speed (<10 nsec), excellent energy resolution, low noise, and ease of achieving compensation and hence linearity. On the negative side of the ledger can be placed the historical sensitivity of plastic scintillators to radiation damage, the possibility of nonuniform response because of light attenuation, and the presence of cracks for light collection via wavelength shifting plastic (traditionally in sheet form). This approach to calorimetry is being investigated for SSC use by a collaboration of Ames Laboratory/Iowa State University, Argonne National Laboratory, Bicron Corporation, Florida State University, Louisiana State University, University of Mississippi, Oak Ridge National Laboratory, Virginia Polytechnic Institute and State University, Westinghouse Electric Corporation, and University of Wisconsin.

  19. An Optimized High Throughput Clean-Up Method Using Mixed-Mode SPE Plate for the Analysis of Free Arachidonic Acid in Plasma by LC-MS/MS

    PubMed Central

    Wang, Wan; Qin, Suzi; Li, Linsen; Chen, Xiaohua; Wang, Qunjie; Wei, Junfu

    2015-01-01

    A high throughput sample preparation method was developed utilizing mixed-mode solid phase extraction (SPE) in 96-well plate format for the determination of free arachidonic acid in plasma by LC-MS/MS. Plasma was mixed with 3% aqueous ammonia and loaded into each well of 96-well plate. After washing with water and methanol sequentially, 3% of formic acid in acetonitrile was used to elute arachidonic acid. The collected fraction was injected onto a reversed phase column at 30°C with mobile phase of acetonitrile/water (70 : 30, v/v) and detected by LC-MS/MS coupled with electrospray ionization (ESI) in multiple reaction monitoring (MRM) mode. The calibration curve ranged from 10 to 2500 ng/mL with sufficient linearity (r2 = 0.9999). The recoveries were in the range of 99.38% to 103.21% with RSD less than 6%. The limit of detection is 3 ng/mL. PMID:25873969

  20. A microELISA assay for detection of anti-HLA activity of mouse monoclonal antibodies using an Astroscan 2100 automated plate reader.

    PubMed

    Sadler, A M; Krausa, P; Marsh, S G; Heyes, J M; Bodmer, J G

    1992-04-27

    A microenzyme-linked immunosorbent assay (microELISA) method has been developed using an Astroscan 2100 system automated plate reader which was initially designed for tissue typing by a two colour fluorescent microcytotoxicity assay. A 96-well plate ELISA used for screening mouse monoclonal antibodies raised against surface HLA antigens has been modified for use with the Astroscan plate reader and 72-well typing trays. The existing substrate 4-methylumbelliferyl-beta-D-galactoside (4MUG) has been replaced with fluorescein-di-beta-D-galactopyranoside (FDG), to provide a wavelength (530 nm) detectable by the Astroscan or other automated plate readers designed for reading microcytotoxicity assay plates. The assay volumes have also been reduced tenfold for use with Terasaki microtest plates. The assay now has the major advantage of requiring only 5 microliters of test supernatant allowing hybridomas to be screened earlier during a fusion and on a wider cell panel. The use of the large panel which includes B lymphoblastoid cell lines (B-LCL) and mouse L cell transfectants expressing HLA genes, reduces the length of time the hybridomas need to be kept in tissue culture before selection. Other advantages include the reduction in the number of target cells required, smaller volumes of reagents throughout the assay and the ability to screen cytotoxic as well as non-cytotoxic monoclonal antibodies. The sensitivity of this microELISA proved to be comparable with the original assay and so provides an efficient screening method for monoclonal antibodies. PMID:1583310

  1. 10. DETAIL OF BUILDER'S PLATE AT NORTH PORTAL. PLATE READS: ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. DETAIL OF BUILDER'S PLATE AT NORTH PORTAL. PLATE READS: 1889, BUILT BY THE BERLIN IRON BRIDGE CO. EAST BERLIN CONN. DOUGLAS & JARVIS PAT. APT. 16, 1878, AP'L 17, 1885. A.P. FORESMAN, WM. S. STARR, T.J. STREBEIGH, COMMISSIONERS. - Pine Creek Bridge, River Road spanning Pine Creek, Jersey Shore, Lycoming County, PA

  2. Measuring Ca²⁺ changes in multiwell format using the Fluorometric Imaging Plate Reader (FLIPR(®)).

    PubMed

    Marshall, Ian C B; Owen, Davina E; McNulty, Shaun

    2013-01-01

    The Fluorometric Imaging Plate Reader (FLIPR) has made a significant contribution to drug discovery programs. The key advantage of FLIPR over conventional plate readers is the ability to measure fluorescence emission from multiple wells (96 wells or 384 wells) simultaneously and with high temporal resolution. Consequently, FLIPR has been used extensively to record dynamic intracellular processes such as changes in intracellular Ca(2+) ion concentration, membrane potential, and pH. Since FLIPR is used to measure a functional response in cells, it is rapidly able to distinguish full agonists, partial agonists, and antagonists at a target of interest, making the system a valuable screening tool for interrogation of compound libraries. Automated FLIPR systems for ultra high throughput have also become available that employ integrated plate stackers, washers and specialized stages to allow users to shuttle cell and compound plates from incubators or storage magazines onto the FLIPR system itself. In this chapter generic methods for assessing intracellular Ca(2+) on the FLIPR are described. PMID:23007581

  3. Plate tectonics conserves angular momentum

    NASA Astrophysics Data System (ADS)

    Bowin, C.

    2010-03-01

    A new combined understanding of plate tectonics, Earth internal structure, and the role of impulse in deformation of the Earth's crust is presented. Plate accelerations and decelerations have been revealed by iterative filtering of the quaternion history for the Euler poles that define absolute plate motion history for the past 68 million years, and provide an unprecedented precision for plate angular rotation variations with time at 2-million year intervals. Stage poles represent the angular rotation of a plate's motion between adjacent Euler poles, and from which the maximum velocity vector for a plate can be determined. The consistent maximum velocity variations, in turn, yield consistent estimates of plate accelerations and decelerations. The fact that the Pacific plate was shown to accelerate and decelerate, implied that conservation of plate tectonic angular momentum must be globally conserved, and that is confirmed by the results shown here (total angular momentum ~1.4+27 kg m2 s-1). Accordingly, if a plate decelerates, other plates must increase their angular momentums to compensate. In addition, the azimuth of the maximum velocity vectors yields clues as to why the "bend" in the Emperor-Hawaiian seamount trend occurred near 46 Myr. This report summarizes processing results for 12 of the 14 major tectonic plates of the Earth (except for the Juan de Fuca and Philippine plates). Plate accelerations support the contention that plate tectonics is a product of torques that most likely are sustained by the sinking of positive density anomalies revealed by geoid anomalies of the degree 4-10 packet of the Earth's spherical harmonic coefficients. These linear positive geoid anomalies underlie plate subduction zones and are presumed due to phase changes in subducted gabbroic lithosphere at depth in the upper lower mantle (above 1200 km depth). The tectonic plates are pulled along by the sinking of these positive mass anomalies, rather than moving at near constant

  4. Plate tectonics, damage and inheritance.

    PubMed

    Bercovici, David; Ricard, Yanick

    2014-04-24

    The initiation of plate tectonics on Earth is a critical event in our planet's history. The time lag between the first proto-subduction (about 4 billion years ago) and global tectonics (approximately 3 billion years ago) suggests that plates and plate boundaries became widespread over a period of 1 billion years. The reason for this time lag is unknown but fundamental to understanding the origin of plate tectonics. Here we suggest that when sufficient lithospheric damage (which promotes shear localization and long-lived weak zones) combines with transient mantle flow and migrating proto-subduction, it leads to the accumulation of weak plate boundaries and eventually to fully formed tectonic plates driven by subduction alone. We simulate this process using a grain evolution and damage mechanism with a composite rheology (which is compatible with field and laboratory observations of polycrystalline rocks), coupled to an idealized model of pressure-driven lithospheric flow in which a low-pressure zone is equivalent to the suction of convective downwellings. In the simplest case, for Earth-like conditions, a few successive rotations of the driving pressure field yield relic damaged weak zones that are inherited by the lithospheric flow to form a nearly perfect plate, with passive spreading and strike-slip margins that persist and localize further, even though flow is driven only by subduction. But for hotter surface conditions, such as those on Venus, accumulation and inheritance of damage is negligible; hence only subduction zones survive and plate tectonics does not spread, which corresponds to observations. After plates have developed, continued changes in driving forces, combined with inherited damage and weak zones, promote increased tectonic complexity, such as oblique subduction, strike-slip boundaries that are subparallel to plate motion, and spalling of minor plates. PMID:24717430

  5. Stepped conical zone plate antenna

    NASA Astrophysics Data System (ADS)

    Wiltse, James C.

    2001-07-01

    The Fresnel zone plate lens was invented and developed for optical frequencies. However, fabrication difficulties at the short optical wavelengths have prevented obtain good efficiencies. At longer microwave or millimeter-wavelengths fabrication is easier and phase correcting zone plate antennas have been used to obtain good efficiencies. This paper describes a new type of phase correcting zone plate having even better efficiency, namely a diffraction efficiency of 99 percent compared to a true lens, and an overall efficiency much better than a true lens. For the usual zone plate antenna employed at microwave or millimeter wavelengths, path length adjustment is accomplished by cutting different depths in a dielectric plate or by using two or more dielectrics having different dielectric constants. The new design uses a tilted cut in a dielectric plate, which more accurately matches the shape of a true lens and produces much lower phase error. The construction is still near and can be made for example, by a milling machine with a tilted bit. For a circular zone plate, the lens is a stepped conical or tapered shape. Because the phase steps are small, the far-field antenna pattern is excellent and sidelobe-levels are very low. Analysis of typical configurations will be given, showing that phase errors are small, lower than those for an eighth-wave corrected phase zone plate.

  6. ChooseMyPlate.gov

    MedlinePlus

    ... Day You don’t have to be an Olympic athlete to be active. Taking the stairs instead of the elevator, mowing the lawn, and gardening count too! TWITTER FEED 2 days ChooseMyPlate.gov @MyPlate Make family dinner more fun with a game or activity. Challenge kids to solve a riddle ...

  7. Micro-channel plate detector

    DOEpatents

    Elam, Jeffrey W.; Lee, Seon W.; Wang, Hsien -Hau; Pellin, Michael J.; Byrum, Karen; Frisch, Henry J.

    2015-09-22

    A method and system for providing a micro-channel plate detector. An anodized aluminum oxide membrane is provided and includes a plurality of nanopores which have an Al coating and a thin layer of an emissive oxide material responsive to incident radiation, thereby providing a plurality of radiation sensitive channels for the micro-channel plate detector.

  8. 21 CFR 862.2680 - Microtitrator for clinical use.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... a device intended for use in micronanalysis to measure the concentration of a substance by reacting it with a measure “micro” volume of a known standardized solution. (b) Classification. Class...

  9. Aseptic Laboratory Techniques: Plating Methods

    PubMed Central

    Sanders, Erin R.

    2012-01-01

    Microorganisms are present on all inanimate surfaces creating ubiquitous sources of possible contamination in the laboratory. Experimental success relies on the ability of a scientist to sterilize work surfaces and equipment as well as prevent contact of sterile instruments and solutions with non-sterile surfaces. Here we present the steps for several plating methods routinely used in the laboratory to isolate, propagate, or enumerate microorganisms such as bacteria and phage. All five methods incorporate aseptic technique, or procedures that maintain the sterility of experimental materials. Procedures described include (1) streak-plating bacterial cultures to isolate single colonies, (2) pour-plating and (3) spread-plating to enumerate viable bacterial colonies, (4) soft agar overlays to isolate phage and enumerate plaques, and (5) replica-plating to transfer cells from one plate to another in an identical spatial pattern. These procedures can be performed at the laboratory bench, provided they involve non-pathogenic strains of microorganisms (Biosafety Level 1, BSL-1). If working with BSL-2 organisms, then these manipulations must take place in a biosafety cabinet. Consult the most current edition of the Biosafety in Microbiological and Biomedical Laboratories (BMBL) as well as Material Safety Data Sheets (MSDS) for Infectious Substances to determine the biohazard classification as well as the safety precautions and containment facilities required for the microorganism in question. Bacterial strains and phage stocks can be obtained from research investigators, companies, and collections maintained by particular organizations such as the American Type Culture Collection (ATCC). It is recommended that non-pathogenic strains be used when learning the various plating methods. By following the procedures described in this protocol, students should be able to: ● Perform plating procedures without contaminating media. ● Isolate single bacterial colonies by the

  10. Present-day plate motions

    NASA Technical Reports Server (NTRS)

    Minster, J. B.; Jordan, T. H.

    1977-01-01

    A data set comprising 110 spreading rates, 78 transform fault azimuths and 142 earthquake slip vectors was inverted to yield a new instantaneous plate motion model, designated RM2. The mean averaging interval for the relative motion data was reduced to less than 3 My. A detailed comparison of RM2 with angular velocity vectors which best fit the data along individual plate boundaries indicates that RM2 performs close to optimally in most regions, with several notable exceptions. On the other hand, a previous estimate (RM1) failed to satisfy an extensive set of new data collected in the South Atlantic Ocean. It is shown that RM1 incorrectly predicts the plate kinematics in the South Atlantic because the presently available data are inconsistent with the plate geometry assumed in deriving RM1. It is demonstrated that this inconsistency can be remedied by postulating the existence of internal deformation with the Indian plate, although alternate explanations are possible.

  11. Impact damage of composite plates

    NASA Technical Reports Server (NTRS)

    Lal, K. M.; Goglia, G. L.

    1983-01-01

    A simple model to study low velocity transverse impact of thin plates made of fiber-reinforced composite material, in particular T300/5208 graphite-epoxy was discussed. This model predicts the coefficient of restitution, which is a measure of the energy absorbed by the target during an impact event. The model is constructed on the assumption that the plate is inextensible in the fiber direction and that the material is incompressible in the z-direction. Such a plate essentially deforms by shear, hence this model neglects bending deformations of the plate. The coefficient of restitution is predicted to increase with large interlaminar shear strength and low transverse shear modulus of the laminate. Predictions are compared with the test results of impacted circular and rectangular clamped plates. Experimentally measured values of the coefficient of restitution are found to agree with the predicted values within a reasonable error.

  12. SAMI Automated Plug Plate Configuration

    NASA Astrophysics Data System (ADS)

    Lorente, N. P. F.; Farrell, T.; Goodwin, M.

    2013-10-01

    The Sydney-AAO Multi-object Integral field spectrograph (SAMI) is a prototype wide-field system at the Anglo-Australian Telescope (AAT) which uses a plug-plate to mount its 13×61-core imaging fibre bundles (hexabundles) in the optical path at the telescope's prime focus. In this paper we describe the process of determining the positions of the plug-plate holes, where plates contain three or more stacked observation configurations. The process, which up until now has involved several separate processes and has required significant manual configuration and checking, is now being automated to increase efficiency and reduce error. This is carried out by means of a thin Java controller layer which drives the configuration cycle. This layer controls the user interface and the C++ algorithm layer where the plate configuration and optimisation is carried out. Additionally, through the Aladin display package, it provides visualisation and facilitates user verification of the resulting plates.

  13. Statistical tests of additional plate boundaries from plate motion inversions

    NASA Technical Reports Server (NTRS)

    Stein, S.; Gordon, R. G.

    1984-01-01

    The application of the F-ratio test, a standard statistical technique, to the results of relative plate motion inversions has been investigated. The method tests whether the improvement in fit of the model to the data resulting from the addition of another plate to the model is greater than that expected purely by chance. This approach appears to be useful in determining whether additional plate boundaries are justified. Previous results have been confirmed favoring separate North American and South American plates with a boundary located beween 30 N and the equator. Using Chase's global relative motion data, it is shown that in addition to separate West African and Somalian plates, separate West Indian and Australian plates, with a best-fitting boundary between 70 E and 90 E, can be resolved. These results are generally consistent with the observation that the Indian plate's internal deformation extends somewhat westward of the Ninetyeast Ridge. The relative motion pole is similar to Minster and Jordan's and predicts the NW-SE compression observed in earthquake mechanisms near the Ninetyeast Ridge.

  14. Sub-Plate Overlap Code Documentation

    NASA Technical Reports Server (NTRS)

    Taff, L. G.; Bucciarelli, B.; Zarate, N.

    1997-01-01

    An expansion of the plate overlap method of astrometric data reduction to a single plate has been proposed and successfully tested. Each plate is (artificially) divided into sub-plates which can then be overlapped. This reduces the area of a 'plate' over which a plate model needs to accurately represent the relationship between measured coordinates and standard coordinates. Application is made to non-astrographic plates such as Schmidt plates and to wide-field astrographic plates. Indeed, the method is completely general and can be applied to any type of recording media.

  15. Highly curved microchannel plates

    NASA Technical Reports Server (NTRS)

    Siegmund, O. H. W.; Cully, S.; Warren, J.; Gaines, G. A.; Priedhorsky, W.; Bloch, J.

    1990-01-01

    Several spherically curved microchannel plate (MCP) stack configurations were studied as part of an ongoing astrophysical detector development program, and as part of the development of the ALEXIS satellite payload. MCP pairs with surface radii of curvature as small as 7 cm, and diameters up to 46 mm have been evaluated. The experiments show that the gain (greater than 1.5 x 10 exp 7) and background characteristics (about 0.5 events/sq cm per sec) of highly curved MCP stacks are in general equivalent to the performance achieved with flat MCP stacks of similar configuration. However, gain variations across the curved MCP's due to variations in the channel length to diameter ratio are observed. The overall pulse height distribution of a highly curved surface MCP stack (greater than 50 percent FWHM) is thus broader than its flat counterpart (less than 30 percent). Preconditioning of curved MCP stacks gives comparable results to flat MCP stacks, but it also decreases the overall gain variations. Flat fields of curved MCP stacks have the same general characteristics as flat MCP stacks.

  16. Balanced Orifice Plate

    NASA Technical Reports Server (NTRS)

    Kelley, Anthony R. (Inventor); Buskirk, Paul D. (Inventor)

    2006-01-01

    An orifice plate for use in a conduit through which fluid flows is defined by a central circular region having a radius R, and a ring-shaped region surrounding the central circular region. The ring-shaped region has holes formed therethrough with those holes centered at each radius R thereof satisfying a relationship A(sub R)=al(X(sub R)V(sub R)(sup b)) where A(sub R) is a sum of areas of those holes having centers at radius R, X(sub R) is a flow coefficient at radius R, V(sub R) is a velocity of the fluid that is to flow through the conduit at radius R, b is a constant selected to make at least one process variable (associated with the fluid that is to flow through the conduit) approximately equal at each radius R, and a is a constant that is equal to (X(sub R)A(sub R)V(sub R)(sup b)) at each radius R.

  17. Mantle convection with plates and mobile, faulted plate margins.

    PubMed

    Zhong, S; Gurnis, M

    1995-02-10

    A finite-element formulation of faults has been incorporated into time-dependent models of mantle convection with realistic rheology, continents, and phase changes. Realistic tectonic plates naturally form with self-consistent coupling between plate and mantle dynamics. After the initiation of subduction, trenches rapidly roll back with subducted slabs temporarily laid out along the base of the transition zone. After the slabs have penetrated into the lower mantle, the velocity of trench migration decreases markedly. The inhibition of slab penetration into the lower mantle by the 670-kilometer phase change is greatly reduced in these models as compared to models without tectonic plates. PMID:17813909

  18. The Golosyiv plate archive digitisation

    NASA Astrophysics Data System (ADS)

    Sergeeva, T. P.; Sergeev, A. V.; Pakuliak, L. K.; Yatsenko, A. I.

    2007-08-01

    The plate archive of the Main Astronomical Observatory of the National Academy of Sciences of Ukraine (Golosyiv, Kyiv) includes about 85 000 plates which have been taken in various observational projects during 1950-2005. Among them are about 25 000 of direct northern sky area plates and more than 600 000 plates containing stellar, planetary and active solar formations spectra. Direct plates have a limiting magnitude of 14.0-16.0 mag. Since 2002 we have been organising the storage, safeguarding, cataloguing and digitization of the plate archive. The very initial task was to create the automated system for detection of astronomical objects and phenomena, search of optical counterparts in the directions of gamma-ray bursts, research of long period, flare and other variable stars, search and rediscovery of asteroids, comets and other Solar System bodies to improve the elements of their orbits, informational support of CCD observations and space projects, etc. To provide higher efficiency of this work we have prepared computer readable catalogues and database for 250 000 direct wide field plates. Now the catalogues have been adapted to Wide Field Plate Database (WFPDB) format and integrated into this world database. The next step will be adaptation of our catalogues, database and images to standards of the IVOA. Some magnitude and positional accuracy estimations for Golosyiv archive plates have been done. The photometric characteristics of the images of NGC 6913 cluster stars on two plates of the Golosyiv's double wide angle astrograph have been determined. Very good conformity of the photometric characteristics obtained with external accuracies of 0.13 and 0.15 mag. has been found. The investigation of positional accuracy have been made with A3± format fixed bed scanner (Microtek ScanMaker 9800XL TMA). It shows that the scanner has non-detectable systematic errors on the X-axis, and errors of ± 15 μm on the Y-axis. The final positional errors are about ± 2 μm (

  19. Turbidimetric assay for tetracyclines in feeds using a microtiter plate system.

    PubMed

    Brady, M S; Katz, S E

    1991-01-01

    The microtiter plate system for turbidimetric assay of chlortetracycline (CTC) and oxytetracycline (OTC) levels in feeds uses a 96 well microtiter plate, a multichannel pipette, and an ELISA reader to measure turbidity. Feeds are extracted for both tetracyclines using AOAC extraction systems. For CTC, the range of the standard curve is 0.001-0.005 microgram CTC/mL; for OTC, the range is 0.004-0.016 microgram OTC/mL. Repeatability of CTC assays, as shown by the coefficient of variation (CV), ranged from 0.54 to 5.65% for same-day assays and from 2.01 to 9.39% for assays on different days. For OTC, CVs ranged from 2.69 to 10.01% for same-day assays and 3.24 to 9.08% for different-day assays. Average recoveries for CTC were 108.7% for same-day assays and 106.8% for different-day assays; for OTC, average recoveries were 112.4% and 106.5% for same-day and different-day assays, respectively. PMID:1874689

  20. Difficulties encountered removing locked plates

    PubMed Central

    Raja, S; Imbuldeniya, AM; S, Garg; Groom, G

    2012-01-01

    INTRODUCTION Locked plates are commonly used to obtain fixation in periarticular and comminuted fractures. Their use has also gained popularity in repairing fractures in osteoporotic bone. These plates provide stable fixation and promote biological healing. Over the last 3 years, we have used over 150 locked plates with varying success to fix periarticular fractures involving mainly the knee and ankle. In this study, we report our clinical experience and the difficulties encountered when removing locked plates in adult patients with a variety of indications including implant failure, infection, non-union and a palpable symptomatic implant. METHODS A retrospective analysis was performed of patients enrolled prospectively into a database. Included in the study were 36 consecutive adult patients who each underwent the procedure of locked plate removal in a single inner city level 1 trauma centre. Data collected included primary indication for fixation, indication for implant removal, time of the implant in situ, grade of operating surgeon and difficulties encountered during the procedure. RESULTS Implant removal was associated with a complication rate of 47%. The major problems encountered were difficulty in removing the locked screws and the implant itself. A total of ten cold welded screws were found in eight cases. Removal was facilitated by high speed metal cutting burrs and screw removal sets in all but one case, where a decision was made to leave the plate in situ. CONCLUSIONS The majority of studies investigating implant removal and problems encountered in doing so report a relatively high complication rate. With the advent of locking plates and their growing popularity, difficulties are now being seen intra-operatively when removing them. There is a paucity of data, however, specifically directed at locking plate removal. We recommend that surgeons should be aware of the potential complications while removing locked plates. Fluoroscopic control and all

  1. High-throughput micro plate assays for screening flavonoid content and DPPH-scavenging activity in sorghum bran and flour

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Rapid, 96-well microtiter assays were compared to conventional assays for quantifying total phenolic content, flavonoid content, and 2,2-diphenyl-1-picrylhydrazyl (DPPH) in sorghum grain. The 96-well assays exhibited a correlation of >0.9 to the conventional assays. The 96-well assays allowed for ...

  2. High loading uranium fuel plate

    DOEpatents

    Wiencek, Thomas C.; Domagala, Robert F.; Thresh, Henry R.

    1990-01-01

    Two embodiments of a high uranium fuel plate are disclosed which contain a meat comprising structured uranium compound confined between a pair of diffusion bonded ductile metal cladding plates uniformly covering the meat, the meat having a uniform high fuel loading comprising a content of uranium compound greater than about 45 Vol. % at a porosity not greater than about 10 Vol. %. In a first embodiment, the meat is a plurality of parallel wires of uranium compound. In a second embodiment, the meat is a dispersion compact containing uranium compound. The fuel plates are fabricated by a hot isostatic pressing process.

  3. Plating on stainless steel alloys

    SciTech Connect

    Dini, J.W.; Johnson, H.R.

    1981-09-11

    Quantitative adhesion data are presented for a variety of electroplated stainless steel type alloys. Results show that excellent adhesion can be obtained by using a Wood's nickel strike or a sulfamate nickel strike prior to final plating. Specimens plated after Wood's nickel striking failed in the deposit rather than at the interface between the substrate and the coating. Flyer plate quantitative tests showed that use of anodic treatment in sulfuric acid prior to Wood's nickel striking even further improved adhesion. In contrast activation of stainless steels by immersion or cathodic treatment in hydrochloric acid resulted in very reduced bond strengths with failure always occurring at the interface between the coating and substrate.

  4. The multigap resistive plate chamber

    SciTech Connect

    Zeballos, E. Cerron; Crotty, I.; Hatzifotiadou, D.; Valverde, J. Lamas; Neupane, S.; Williams, M. C. S.; Zichichi, A.

    2015-02-03

    The paper describes the multigap resistive plate chamber (RPC). This is a variant of the wide gap RPC. However it has much improved time resolution, while keeping all the other advantages of the wide gap RPC design.

  5. Quaternions as astrometric plate constants

    NASA Technical Reports Server (NTRS)

    Jefferys, William H.

    1987-01-01

    A new method for solving problems in relative astrometry is proposed. In it, the relationship between the measured quantities and the components of the position vector of a star is modeled using quaternions, in effect replacing the plate constants of a standard four-plate-constant solution with the four components of a quaternion. The method allows a direct solution for the position vectors of the stars, and hence for the equatorial coordinates. Distortions, magnitude, and color effects are readily incorporated into the formalism, and the method is directly applicable to overlapping-plate problems. The advantages of the method include the simplicity of the resulting equations, their freedom from singularities, and the fact that trigonometric functions and tangential point transformations are not needed to model the plate material. A global solution over the entire sky is possible.

  6. Carbon-assisted flyer plates

    DOEpatents

    Stahl, D.B.; Paisley, D.L.

    1994-04-12

    A laser driven flyer plate is described utilizing an optical fiber connected to a laser. The end of the optical fiber has a layer of carbon and a metal layer deposited onto it. The carbon layer provides the laser induced plasma which is superior to the plasma produced from most metals. The carbon layer plasma is capable of providing a flatter flyer plate, converting more of the laser energy to driving plasma, promoting a higher flyer plate acceleration, and providing a more uniform pulse behind the plate. In another embodiment, the laser is in optical communication with a substrate onto which a layer of carbon and a layer of metal have been deposited. 2 figures.

  7. Pulse plating of nickel deposits

    SciTech Connect

    Stimetz, C.J.; Stevenson, M.F.

    1980-02-01

    Pulse plated and conventional nickel deposits have been compared for differences in morphology, mechanical properties, and microstructure. The deposits were obtained from nickel sulfamate, nickel chloride, and Watts nickel plating solutions. No significant differences were found in the direct and pulse current deposits from the sulfamate and chloride solutions; however, significant differences in microstructure, yield strength, and microhardness were observed in deposits from the Watts nickel solution.

  8. Spore immobilization and its analytical performance for monitoring of aflatoxin M1 in milk.

    PubMed

    Singh, V K; Singh, N A; Kumar, N; Raghu, H V; Sharma, Pradeep Kumar; Singh, K P; Yadav, Avinash

    2014-12-01

    Immobilization of Bacillus megaterium spores on Eppendorf tubes through physical adsorption has been used in the detection of aflatoxin M1 (AFM1) in milk within real time of 45 ± 5 min using visual observation of changes in a chromogenic substrate. The appearance of a sky-blue colour indicates the absence of AFM1 in milk, whereas no colour change indicates the presence of AFM1 in milk at a 0.5 ppb Codex maximum residue limit. The working performance of the immobilized spores was shown to persist for up to 6 months. Further, spores immobilized on 96-well black microtitre plates by physical adsorption and by entrapment on sensor disk showed a reduction in detection sensitivity to 0.25 ppb within a time period of 20 ± 5 min by measuring fluorescence using a microbiological plate reader through the addition of milk and fluorogenic substrate. A high fluorescence ratio indicated more substrate hydrolysis due to spore-germination-mediated release of marker enzymes of spores in the absence of AFM1 in milk; however, low fluorescence ratios indicated the presence of AFM1 at 0.25 ppb. Immobilized spores on 96-well microtitre plates and sensor disks have shown better reproducibility after storage at 4 °C for 6 months. Chromogenic assay showed 1.38% false-negative and 2.77% false-positive results while fluorogenic assay showed 4.16% false-positive and 2.77% false-negative results when analysed for AFM1 using 72 milk samples containing raw, pasteurized, and dried milk. Immobilization of spores makes these chromogenic and fluorogenic assays portable, selective, cost-effective for real-time detection of AFM1 in milk at the dairy farm, reception dock, and manufacturing units of the dairy industry. PMID:25387994

  9. Impact on multilayered composite plates

    NASA Technical Reports Server (NTRS)

    Kim, B. S.; Moon, F. C.

    1977-01-01

    Stress wave propagation in a multilayer composite plate due to impact was examined by means of the anisotropic elasticity theory. The plate was modelled as a number of identical anisotropic layers and the approximate plate theory of Mindlin was then applied to each layer to obtain a set of difference-differential equations of motion. Dispersion relations for harmonic waves and correction factors were found. The governing equations were reduced to difference equations via integral transforms. With given impact boundary conditions these equations were solved for an arbitrary number of layers in the plate and the transient propagation of waves was calculated by means of a Fast Fourier Transform algorithm. The multilayered plate problem was extended to examine the effect of damping layers present between two elastic layers. A reduction of the interlaminar normal stress was significant when the thickness of damping layer was increased but the effect was mostly due to the softness of the damping layer. Finally, the problem of a composite plate with a crack on the interlaminar boundary was formulated.

  10. How mantle slabs drive plate tectonics.

    PubMed

    Conrad, Clinton P; Lithgow-Bertelloni, Carolina

    2002-10-01

    The gravitational pull of subducted slabs is thought to drive the motions of Earth's tectonic plates, but the coupling between slabs and plates is not well established. If a slab is mechanically attached to a subducting plate, it can exert a direct pull on the plate. Alternatively, a detached slab may drive a plate by exciting flow in the mantle that exerts a shear traction on the base of the plate. From the geologic history of subduction, we estimated the relative importance of "pull" versus "suction" for the present-day plates. Observed plate motions are best predicted if slabs in the upper mantle are attached to plates and generate slab pull forces that account for about half of the total driving force on plates. Slabs in the lower mantle are supported by viscous mantle forces and drive plates through slab suction. PMID:12364804

  11. Plate mode velocities in graphite/epoxy plates

    NASA Technical Reports Server (NTRS)

    Prosser, W. H.; Gorman, M. R.

    1994-01-01

    Measurements of the velocities of the extensional and flexural plate modes were made along three directions of propagation in four graphite/epoxy composite plates. The acoustic signals were generated by simulated acoustic emission events (pencil lead breaks or Hsu-Neilson sources) and detected by by broadband ultrasonic transducers. The first arrival of the extensional plate mode, which is nondispersive at low frequencies, was measured at a number of different distances from the source along the propagation direction of interest. The velocity was determined by plotting the distance versus arrival time and computing its slope. Because of the large dispersion of the flexural mode, a Fourier phase velocity technique was used to characterize this mode. The velocity was measured up to a frequency of 160 kHz. Theoretical predictions of the velocities of these modes were also made and compared with experimental observations. Classical plate theory yields good agreement with the measured extensional velocities. For predictions of the dispersion of the flexural mode, Mindlin plates theory, which includes the effects of shear deformation and rotatory inertia was shown to give better agreement with the experimental measurements.

  12. Wide-Field Plate Database: Included Ukrainian Plate Catalogues

    NASA Astrophysics Data System (ADS)

    Tsvetkova, Katya; Sergeeva, Tetyana

    2007-08-01

    We present the basic information for the archives of the Main Astronomical Observatory of the National Academy of Sciences of Ukraine, included into the Wide-Field Plate Database last two years with total number of plates - 11260. The plates were obtained with the 0.40m Double Wide-angle Astrograph (DWA); 10cm, 11cm and 15cm Three Cameras Astrograph (TCA) and 12 cm Double Short focus Astrograph (DSA) in the period 1949-1998 in the frames of the following observing programmes: Photographic Survey of the Northern Sky; Investigation of the kinematics and the structure in the main meridian section of the Galaxy; selection of reference stars, minor planets observations, comet investigations.

  13. 30 CFR 20.13 - Approval plate.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... plate shall be satisfactory to MSHA. (a) Purpose of approval plate. The approval plate is a label which.... By it the manufacturer can point out that his lamp complies with specifications of MSHA and that it... place MSHA's approval plate on his lamp obligates the manufacturer to maintain the quality of...

  14. 49 CFR 451.23 - Plate specifications.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 6 2013-10-01 2013-10-01 false Plate specifications. 451.23 Section 451.23... SECURITY SAFETY APPROVAL OF CARGO CONTAINERS TESTING AND APPROVAL OF CONTAINERS Safety Approval Plate § 451.23 Plate specifications. (a) The safety approval plate must be of the size and in the...

  15. 49 CFR 451.23 - Plate specifications.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 6 2010-10-01 2010-10-01 false Plate specifications. 451.23 Section 451.23... SECURITY SAFETY APPROVAL OF CARGO CONTAINERS TESTING AND APPROVAL OF CONTAINERS Safety Approval Plate § 451.23 Plate specifications. (a) The safety approval plate must be of the size and in the...

  16. 49 CFR 451.23 - Plate specifications.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 6 2014-10-01 2014-10-01 false Plate specifications. 451.23 Section 451.23... SECURITY SAFETY APPROVAL OF CARGO CONTAINERS TESTING AND APPROVAL OF CONTAINERS Safety Approval Plate § 451.23 Plate specifications. (a) The safety approval plate must be of the size and in the...

  17. 49 CFR 451.23 - Plate specifications.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 6 2012-10-01 2012-10-01 false Plate specifications. 451.23 Section 451.23... SECURITY SAFETY APPROVAL OF CARGO CONTAINERS TESTING AND APPROVAL OF CONTAINERS Safety Approval Plate § 451.23 Plate specifications. (a) The safety approval plate must be of the size and in the...

  18. Beyond plate tectonics - Looking at plate deformation with space geodesy

    NASA Technical Reports Server (NTRS)

    Jordan, Thomas H.; Minster, J. Bernard

    1988-01-01

    The requirements that must be met by space-geodetic systems in order to constrain the horizontal secular motions associated with the geological deformation of the earth's surface are explored. It is suggested that in order to improve existing plate-motion models, the tangential components of relative velocities on interplate baselines must be resolved to an accuracy of less than 3 mm/yr. Results indicate that measuring the velocities between crustal blocks to + or - 5 mm/yr on 100-km to 1000-km scales can produce geologically significant constraints on the integrated deformation rates across continental plate-boundary zones such as the western United States.

  19. Plating on some difficult-to-plate metals and alloys

    SciTech Connect

    Dini, J.W.; Johnson, H.R.

    1980-02-01

    Electrodeposition of coatings on metals such as beryllium, beryllium-copper, Kovar, lead, magnesium, thorium, titanium, tungsten, uranium, zirconium, and their alloys can be problematic. This is due in most cases to a natural oxide surface film that readily reforms after being removed. The procedures we recommend for plating on these metals rely on replacing the oxide film with a displacement coating, or etching to allow mechanical keying between the substrate and plated deposit. The effectiveness of the procedures is demonstrated by interface bond strengths found in ring-shear and conical-head tensile tests.

  20. Plates for vacuum thermal fusion

    DOEpatents

    Davidson, James C.; Balch, Joseph W.

    2002-01-01

    A process for effectively bonding arbitrary size or shape substrates. The process incorporates vacuum pull down techniques to ensure uniform surface contact during the bonding process. The essence of the process for bonding substrates, such as glass, plastic, or alloys, etc., which have a moderate melting point with a gradual softening point curve, involves the application of an active vacuum source to evacuate interstices between the substrates while at the same time providing a positive force to hold the parts to be bonded in contact. This enables increasing the temperature of the bonding process to ensure that the softening point has been reached and small void areas are filled and come in contact with the opposing substrate. The process is most effective where at least one of the two plates or substrates contain channels or grooves that can be used to apply vacuum between the plates or substrates during the thermal bonding cycle. Also, it is beneficial to provide a vacuum groove or channel near the perimeter of the plates or substrates to ensure bonding of the perimeter of the plates or substrates and reduce the unbonded regions inside the interior region of the plates or substrates.

  1. Insert metering plates for gas turbine nozzles

    DOEpatents

    Burdgick, Steven S.; Itzel, Gary; Chopra, Sanjay; Abuaf, Nesim; Correia, Victor H.

    2004-05-11

    The invention comprises a metering plate which is assembled to an impingement insert for use in the nozzle of a gas turbine. The metering plate can have one or more metering holes and is used to balance the cooling flow within the nozzle. A metering plate with multiple holes reduces static pressure variations which result from the cooling airflow through the metering plate. The metering plate can be assembled to the insert before or after the insert is inserted into the nozzle.

  2. Surface crack problems in plates

    NASA Technical Reports Server (NTRS)

    Joseph, P. F.; Erdogan, F.

    1989-01-01

    The mode I crack problem in plates under membrane loading and bending is reconsidered. The purpose is to examine certain analytical features of the problem further and to provide some new results. The formulation and the results given by the classical and the Reissner plate theories for through and part-through cracks are compared. For surface cracks the three-dimensional finite element solution is used as the basis of comparison. The solution is obtained and results are given for the crack/contact problem in a plate with a through crack under pure bending and for the crack interaction problem. Also, a procedure is developed to treat the problem of subcritical crack growth and to trace the evolution of the propagating crack.

  3. Dual polarization flat plate antenna

    NASA Astrophysics Data System (ADS)

    Kelly, Kenneth C.

    Rectangular waveguides with radiating slots are used in groups to form planar array microwave antennas with large apertures and small depth. Such flat plate antennas are widely used on spacecraft and aircraft. Typically, flat plate antennas provide fixed linear polarization. The present paper describes a new flat plate antenna which produces two coincident beams that are distinguished by their orthogonal linear polarizations. The antenna has two ports, one for each of the coicident beams. Completely external to the antenna, connecting a simple network to those terminal ports enables the antenna to provide right circular polarization from one port and left from the other. A different external network enables the antenna to have arbitrarily adjustable polarizations.

  4. Achromatic axially symmetric wave plate.

    PubMed

    Wakayama, Toshitaka; Komaki, Kazuki; Otani, Yukitoshi; Yoshizawa, Toru

    2012-12-31

    An achromatic axially symmetric wave plate (AAS-WP) is proposed that is based on Fresnel reflections. The wave plate does not introduce spatial dispersion. It provides retardation in the wavelength domain with an axially symmetric azimuthal angle. The optical configuration, a numerical simulation, and the optical properties of the AAS-WP are described. It is composed of PMMA. A pair of them is manufactured on a lathe. In the numerical simulation, the achromatic angle is estimated and is used to design the devices. They generate an axially symmetric polarized beam. The birefringence distribution is measured in order to evaluate the AAS-WPs. PMID:23388751

  5. Overriding Plate Controls on Subduction Zone Evolution

    NASA Astrophysics Data System (ADS)

    Sharples, W. K.; Jadamec, M. A.; Moresi, L. N.; Capitanio, F. A.

    2014-12-01

    Seismic data, rock deformation experiments, and geochemical studies indicate variability in the thickness, buoyancy, and strength of the lithosphere at plate boundaries. However, geodynamic models of subduction commonly either omit an overriding plate or do not investigate role of the variation in overriding plate properties on the subduction evolution. We present time-dependent numerical models of subduction that vary the overriding plate thickness, strength, and density and allow for a plate interface that evolves with time via an anisotropic brittle failure rheology. We examine the emergence of (a) asymmetric versus symmetric subduction, (b) trench retreat versus advance, (c) subduction zone geometry, (d) slab stagnation versus penetration into the lower mantle, and (e) flat slab subduction. The majority of the models result in sustained asymmetric subduction. The models demonstrate that trench retreat is correlated with a thin overriding plate, whereas, trench advance is correlated with a thick and/or strong overriding plate. Slab dip, measured at a depth below the plate boundary interface, has a negative correlation with an increase in overriding plate thickness. Overriding plate thickness exerts a first order control over slab penetration into the lower mantle, with penetration most commonly occurring in models with a thick overriding plate. Periods of flat slab subduction occur with thick, strong overriding plates producing strong plate boundary interface coupling. The results provide insight into how the overriding plate plays a role in establishing advancing and retreating subduction, as well as providing an explanation for the variation of slab geometry observed in subduction zones on Earth.

  6. Elastic stability of thick auxetic plates

    NASA Astrophysics Data System (ADS)

    Lim, Teik-Cheng

    2014-04-01

    Auxetic materials and structures exhibit a negative Poisson’s ratio while thick plates encounter shear deformation, which is not accounted for in classical plate theory. This paper investigates the effect of a negative Poisson’s ratio on thick plates that are subjected to buckling loads, taking into consideration the shear deformation using Mindlin plate theory. Using a highly accurate shear correction factor that allows for the effect of Poisson’s ratio, the elastic stability of circular and square plates are evaluated in terms of dimensionless parameters, namely the Mindlin-to-Kirchhoff critical buckling load ratio and Mindlin critical buckling load factors. Results for thick square plates reveal that both parameters increase as the Poisson’s ratio becomes more negative. In the case of thick circular plates, the Mindlin-to-Kirchhoff critical buckling load ratios and the Mindlin critical buckling load factors increase and decrease, respectively, as the Poisson’s ratio becomes more negative. The results obtained herein show that thick auxetic plates behave as thin conventional plates, and therefore suggest that the classical plate theory can be used to evaluate the elastic stability of thick plates if the Poisson’s ratio of the plate material is sufficiently negative. The results also suggest that materials with highly negative Poisson’s ratios are recommended for square plates, but not circular plates, that are subjected to buckling loads.

  7. Petroleum occurrences and plate tectonics

    SciTech Connect

    Olenin, V.B.; Sokolov, B.A.

    1983-01-01

    This paper analyzes the mechanisms of petroleum formation and petroleum accumulation proposed in recent years by some Russian and foreign investigators from the viewpoint of the new global or plate tectonics. On the basis of discussion and the facts, the authors conclude that the mechanisms proposed are in contradiction to reality and their use in practical application is at least premature.

  8. Plated wire random access memories

    NASA Technical Reports Server (NTRS)

    Gouldin, L. D.

    1975-01-01

    A program was conducted to construct 4096-work by 18-bit random access, NDRO-plated wire memory units. The memory units were subjected to comprehensive functional and environmental tests at the end-item level to verify comformance with the specified requirements. A technical description of the unit is given, along with acceptance test data sheets.

  9. Corrosion resistant metallic bipolar plate

    DOEpatents

    Brady, Michael P.; Schneibel, Joachim H.; Pint, Bruce A.; Maziasz, Philip J.

    2007-05-01

    A corrosion resistant, electrically conductive component such as a bipolar plate for a PEM fuel cell includes 20 55% Cr, balance base metal such as Ni, Fe, or Co, the component having thereon a substantially external, continuous layer of chromium nitride.

  10. The seismotectonics of plate boundaries

    NASA Technical Reports Server (NTRS)

    Berger, J.; Brune, J. N.; Goodkind, J.; Wyatt, F.; Agnew, D. C.; Beaumont, C.

    1981-01-01

    Research on the seismotectonics of plate boundaries is summarized. Instrumental development and an observational program designed to study various aspects of the seismotectonics of southern California and the northern Gulf of California are described. A unique superconducting gravimeter was further developed and supported under this program for deployment and operation at several sites. Work on Earth tides is also discussed.

  11. Avionics Box Cold Plate Damage Prevention

    NASA Technical Reports Server (NTRS)

    Stambolian, Damon B.; Larchar, Steven W.; Henderson, Gena; Tran, Donald; Barth, Tim

    2012-01-01

    Problem Introduction: 1. Prevent Cold Plate Damage in Space Shuttle. 1a. The number of cold plate problems had increased from an average of 16.5 per/year between 1990 through 2000, to an average of 39.6 per year between 2001through 2005. 1b. Each complete set of 80 cold plates cost approximately $29 million, an average of $362,500 per cold plate. 1c It takes four months to produce a single cold plate. 2. Prevent Cold Plate Damage in Future Space Vehicles.

  12. Consecutive plate acoustic suppressor apparatus and methods

    NASA Technical Reports Server (NTRS)

    Doychak, Joseph (Inventor); Parrott, Tony (Inventor)

    1992-01-01

    An apparatus and method for suppressing acoustic noise utilizes consecutive plates, closely spaced to each other so as to exploit dissipation associated with sound propagation in narrow channels to optimize the acoustic resistance at a liner surface. The closely spaced plates can be utilized as high temperature structural materials for jet engines by constructing the plates from composite materials. Geometries of the plates, such as plate depth, shape, thickness, inter-plate spacing, arrangement, etc., can be selected to achieve bulk material-like behavior.

  13. Consecutive Plate Acoustic Suppressor Apparatus and Methods

    NASA Technical Reports Server (NTRS)

    Doychak, Joseph (Inventor); Parrott, Tony L. (Inventor)

    1993-01-01

    An apparatus and method for suppressing acoustic noise utilizes consecutive plates, closely spaced to each other so as to exploit dissipation associated with sound propagation in narrow channels to optimize the acoustic resistance at a liner surface. The closely spaced plates can be utilized as high temperature structural materials for jet engines by constructing the plates from composite materials. Geometries of the plates, such as plate depth, shape, thickness, inter-plate spacing, arrangement, etc., can be selected to achieve bulk material-like behavior.

  14. A robust electrochemiluminescence immunoassay for carcinoembryonic antigen detection based on a microtiter plate as a bridge and Au@Pd nanorods as a peroxidase mimic.

    PubMed

    Zhang, Yong; Pang, Xuehui; Wu, Dan; Ma, Hongmin; Yan, Zhaoqing; Zhang, Jiatao; Du, Bin; Wei, Qin

    2016-01-01

    The common drawbacks of most traditional electrochemiluminescence (ECL) immunoassays are the strict storage conditions for the ECL electrode and the steric hindrance caused by bovine serum albumin and antigen. The strict storage conditions require that the modified electrode must be stored at 4 °C before measurement, which may cause the degradation of protein molecules and low reproducibility as the time goes by. The steric hindrance can hinder electron transfer between the electrode and the electrochemical active substance unable to transmit proteins on the electrode surface. The current study takes a 96-well microtiter plate (MTP) as a bridge for analyte pre-treatment and Au@Pd nanorods as a peroxidase mimic to assemble a simple and robust ECL immunoassay. Advantages of such assay include not only high sensitivity but also robust detection circumstance. We demonstrated the method by detecting carcinoembryonic antigen from human serum and obtained a good detection limit of 3 fg mL(-1). PMID:26609799

  15. Maps, Plates, and Mount Saint Helens.

    ERIC Educational Resources Information Center

    Lary, Barbara E.; Krockover, Gerald H.

    1987-01-01

    Describes a laboratory activity on plate tectonics which focuses on the connection between plate tectonics and the different types of volcanoes. Provides questions for discussion and includes suggestions for extending the activity. (ML)

  16. Plating by glass-bead peening

    NASA Technical Reports Server (NTRS)

    Babecki, A. J.; Haehner, C. L.

    1971-01-01

    Technique permits plating of primarily metallic substrates with either metals or nonmetals at normal temperature. Peening uses compressed air to apply concurrent streams of small glass beads and powdered plating material to the substrate.

  17. 49 CFR 230.46 - Badge plates.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... TRANSPORTATION STEAM LOCOMOTIVE INSPECTION AND MAINTENANCE STANDARDS Boilers and Appurtenances Steam Gauges § 230.46 Badge plates. A metal badge plate showing the allowed steam pressure shall be attached to...

  18. 49 CFR 230.46 - Badge plates.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... TRANSPORTATION STEAM LOCOMOTIVE INSPECTION AND MAINTENANCE STANDARDS Boilers and Appurtenances Steam Gauges § 230.46 Badge plates. A metal badge plate showing the allowed steam pressure shall be attached to...

  19. 49 CFR 230.46 - Badge plates.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... TRANSPORTATION STEAM LOCOMOTIVE INSPECTION AND MAINTENANCE STANDARDS Boilers and Appurtenances Steam Gauges § 230.46 Badge plates. A metal badge plate showing the allowed steam pressure shall be attached to...

  20. 49 CFR 230.46 - Badge plates.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... TRANSPORTATION STEAM LOCOMOTIVE INSPECTION AND MAINTENANCE STANDARDS Boilers and Appurtenances Steam Gauges § 230.46 Badge plates. A metal badge plate showing the allowed steam pressure shall be attached to...

  1. 49 CFR 230.46 - Badge plates.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... TRANSPORTATION STEAM LOCOMOTIVE INSPECTION AND MAINTENANCE STANDARDS Boilers and Appurtenances Steam Gauges § 230.46 Badge plates. A metal badge plate showing the allowed steam pressure shall be attached to...

  2. Aluminum transfer method for plating plastics

    NASA Technical Reports Server (NTRS)

    Goodrich, W. D.; Stalmach, C. J., Jr.

    1977-01-01

    Electroless plating technique produces plate of uniform thickness. Hardness and abrasion resistance can be increased further by heat treatment. Method results in seamless coating over many materials, has low thermal conductivity, and is relatively inexpensive compared to conventional methods.

  3. Electrically induced mechanical precompression of ferroelectric plates

    DOEpatents

    Chen, P.J.

    1987-03-02

    A method of electrically inducing mechanical precompression of ferroelectric plate covered with electrodes utilizes the change in strains of the plate as functions of applied electric field. A first field polarizes and laterally shrinks the entire plate. An outer portion of the electrodes are removed, and an opposite field partially depolarizes and expands the central portion of the plate against the shrunk outer portion. 2 figs.

  4. Practical automatic Arabic license plate recognition system

    NASA Astrophysics Data System (ADS)

    Mohammad, Khader; Agaian, Sos; Saleh, Hani

    2011-02-01

    Since 1970's, the need of an automatic license plate recognition system, sometimes referred as Automatic License Plate Recognition system, has been increasing. A license plate recognition system is an automatic system that is able to recognize a license plate number, extracted from image sensors. In specific, Automatic License Plate Recognition systems are being used in conjunction with various transportation systems in application areas such as law enforcement (e.g. speed limit enforcement) and commercial usages such as parking enforcement and automatic toll payment private and public entrances, border control, theft and vandalism control. Vehicle license plate recognition has been intensively studied in many countries. Due to the different types of license plates being used, the requirement of an automatic license plate recognition system is different for each country. [License plate detection using cluster run length smoothing algorithm ].Generally, an automatic license plate localization and recognition system is made up of three modules; license plate localization, character segmentation and optical character recognition modules. This paper presents an Arabic license plate recognition system that is insensitive to character size, font, shape and orientation with extremely high accuracy rate. The proposed system is based on a combination of enhancement, license plate localization, morphological processing, and feature vector extraction using the Haar transform. The performance of the system is fast due to classification of alphabet and numerals based on the license plate organization. Experimental results for license plates of two different Arab countries show an average of 99 % successful license plate localization and recognition in a total of more than 20 different images captured from a complex outdoor environment. The results run times takes less time compared to conventional and many states of art methods.

  5. Electrically induced mechanical precompression of ferroelectric plates

    DOEpatents

    Chen, Peter J.

    1987-01-01

    A method of electrically inducing mechanical precompression of a ferroelectric plate covered with electrodes utilizes the change in strains of the plate as functions of applied electric field. A first field polarizes and laterally shrinks the entire plate. An outer portion of the electrodes are removed, and an opposite field partially depolarizes and expands the central portion of the plate against the shrunk outer portion.

  6. Electrochemical Assay of Gold-Plating Solutions

    NASA Technical Reports Server (NTRS)

    Chiodo, R.

    1982-01-01

    Gold content of plating solution is assayed by simple method that required only ordinary electrochemical laboratory equipment and materials. Technique involves electrodeposition of gold from solution onto electrode, the weight gain of which is measured. Suitable fast assay methods are economically and practically necessary in electronics and decorative-plating industries. If gold content in plating bath is too low, poor plating may result, with consequent economic loss to user.

  7. Ion plated electronic tube device

    DOEpatents

    Meek, T.T.

    1983-10-18

    An electronic tube and associated circuitry which is produced by ion plating techniques. The process is carried out in an automated process whereby both active and passive devices are produced at very low cost. The circuitry is extremely reliable and is capable of functioning in both high radiation and high temperature environments. The size of the electronic tubes produced are more than an order of magnitude smaller than conventional electronic tubes.

  8. Electroless metal plating of plastics

    DOEpatents

    Krause, L.J.

    1982-09-20

    Process for plating main group metals on aromatic polymers is carried out by the use of a nonaqueous solution of a salt of an alkali metal in a positive valence state and a main group metal in a negative valence state with contact between the solution and polymer providing a redox reaction causing the deposition of the main group metal and the reduction of the polymer. Products from the process exhibit useful decorative and electrical properties.

  9. Electroless metal plating of plastics

    DOEpatents

    Krause, Lawrence J.

    1986-01-01

    Process for plating main group metals on aromatic polymers is carried out by the use of a nonaqueous solution of a salt of an alkali metal in a positive valence state and a main group metal in a negative valence state with contact between the solution and polymer providing a redox reaction causing the deposition of the main group metal and the reduction of the polymer. Products from the process exhibit useful decorative and electrical properties.

  10. Electroless metal plating of plastics

    DOEpatents

    Krause, Lawrence J.

    1984-01-01

    Process for plating main group metals on aromatic polymers is carried out by the use of a nonaqueous solution of a salt of an alkali metal in a positive valence state and a main group metal in a negative valence state with contact between the solution and polymer providing a redox reaction causing the deposition of the main group metal and the reduction of the polymer. Products from the process exhibit useful decorative and electrical properties.

  11. PRETREATING URANIUM FOR METAL PLATING

    DOEpatents

    Wehrmann, R.F.

    1961-05-01

    A process is given for anodically treating the surface of uranium articles, prior to metal plating. The metal is electrolyzed in an aqueous solution of about 10% polycarboxylic acid, preferably oxalic acid, from 1 to 5% by weight of glycerine and from 1 to 5% by weight of hydrochloric acid at from 20 to 75 deg C for from 30 seconds to 15 minutes. A current density of from 60 to 100 amperes per square foot is used.

  12. Syncytial-Type Cell Plates

    PubMed Central

    Otegui, Marisa; Staehelin, L. Andrew

    2000-01-01

    Cell wall formation in the syncytial endosperm of Arabidopsis was studied by using high-pressure-frozen/freeze-substituted developing seeds and immunocytochemical techniques. The endosperm cellularization process begins at the late globular embryo stage with the synchronous organization of small clusters of oppositely oriented microtubules (∼10 microtubules in each set) into phragmoplast-like structures termed mini-phragmoplasts between both sister and nonsister nuclei. These mini-phragmoplasts produce a novel kind of cell plate, the syncytial-type cell plate, from Golgi-derived vesicles ∼63 nm in diameter, which fuse by way of hourglass-shaped intermediates into wide (∼45 nm in diameter) tubules. These wide tubules quickly become coated and surrounded by a ribosome-excluding matrix; as they grow, they branch and fuse with each other to form wide tubular networks. The mini-phragmoplasts formed between a given pair of nuclei produce aligned tubular networks that grow centrifugally until they merge into a coherent wide tubular network with the mini-phragmoplasts positioned along the network margins. The individual wide tubular networks expand laterally until they meet and eventually fuse with each other at the sites of the future cell corners. Transformation of the wide tubular networks into noncoated, thin (∼27 nm in diameter) tubular networks begins at multiple sites and coincides with the appearance of clathrin-coated budding structures. After fusion with the syncytial cell wall, the thin tubular networks are converted into fenestrated sheets and cell walls. Immunolabeling experiments show that the cell plates and cell walls of the endosperm differ from those of the embryo and maternal tissue in two features: their xyloglucans lack terminal fucose residues on the side chain, and callose persists in the cell walls after the cell plates fuse with the parental plasma membrane. The lack of terminal fucose residues on xyloglucans suggests that these cell wall

  13. Episodic plate tectonics on Venus

    NASA Technical Reports Server (NTRS)

    Turcotte, Donald

    1992-01-01

    Studies of impact craters on Venus from the Magellan images have placed important constraints on surface volcanism. Some 840 impact craters have been identified with diameters ranging from 2 to 280 km. Correlations of this impact flux with craters on the Moon, Earth, and Mars indicate a mean surface age of 0.5 +/- 0.3 Ga. Another important observation is that 52 percent of the craters are slightly fractured and only 4.5 percent are embayed by lava flows. These observations led researchers to hypothesize that a pervasive resurfacing event occurred about 500 m.y. ago and that relatively little surface volcanism has occurred since. Other researchers have pointed out that a global resurfacing event that ceased about 500 MYBP is consistent with the results given by a recent study. These authors carried out a series of numerical calculations of mantle convection in Venus yielding thermal evolution results. Their model considered crustal recycling and gave rapid planetary cooling. They, in fact, suggested that prior to 500 MYBP plate tectonics was active in Venus and since 500 MYBP the lithosphere has stabilized and only hot-spot volcanism has reached the surface. We propose an alternative hypothesis for the inferred cessation of surface volcanism on Venus. We hypothesize that plate tectonics on Venus is episodic. Periods of rapid plate tectonics result in high rates of subduction that cool the interior resulting in more sluggish mantle convection.

  14. Volcano spacing and plate rigidity

    SciTech Connect

    Brink, U. )

    1991-04-01

    In-plane stresses, which accompany the flexural deformation of the lithosphere under the load adjacent volcanoes, may govern the spacing of volcanoes in hotspot provinces. Specifically, compressive stresses in the vicinity of a volcano prevent new upwelling in this area, forcing a new volcano to develop at a minimum distance that is equal to the distance in which the radial stresses change from compressional to tensile (the inflection point). If a volcano is modeled as a point load on a thin elastic plate, then the distance to the inflection point is proportional to the thickness of the plate to the power of 3/4. Compilation of volcano spacing in seven volcanic groups in East Africa and seven volcanic groups of oceanic hotspots shows significant correlation with the elastic thickness of the plate and matches the calculated distance to the inflection point. In contrast, volcano spacing in island arcs and over subduction zones is fairly uniform and is much larger than predicted by the distance to the inflection point, reflecting differences in the geometry of the source and the upwelling areas.

  15. Plating of proximal humeral fractures.

    PubMed

    Martetschläger, Frank; Siebenlist, Sebastian; Weier, Michael; Sandmann, Gunther; Ahrens, Philipp; Braun, Karl; Elser, Florian; Stöckle, Ulrich; Freude, Thomas

    2012-11-01

    The optimal treatment for proximal humeral fractures is controversial. Few data exist concerning the influence of the surgical approach on the outcome. The purpose of this study was to evaluate the clinical and radiological outcomes of proximal humeral fractures treated with locking plate fixation through a deltopectoral vs an anterolateral deltoid-splitting approach. Of 86 patients who met the inclusion criteria, 70 were available for follow-up examination. Thirty-three patients were treated through a deltopectoral approach and 37 through an anterolateral deltoid-splitting approach. In all cases, open reduction and internal fixation with a PHILOS locking plate (Synthes, Umkirch, Germany) was performed. Clinical follow-up included evaluation of pain, shoulder mobility, and strength. Constant score and Disabilities of the Arm, Shoulder and Hand (DASH) score were assessed. A clinical neurological examination of the axillary nerve was also performed. Consolidation, reduction, and appearance of head necrosis were evaluated radiographically. After a mean follow-up of 33 months, Constant scores, DASH scores, and American Shoulder and Elbow Surgeons scores showed no significant differences between the groups. Clinical neurologic examination of the axillary nerve revealed no obvious damage to the nerve in either group. Deltopectoral and anterolateral detoid-splitting approaches for plate fixation of proximal humeral fractures are safe and provide similar clinical outcomes. The results of this study suggest that the approach can be chosen according to surgeon preference. PMID:23127451

  16. MTR plates modeling with MAIA

    SciTech Connect

    Marelle, V.; Dubois, S.; Ripert, M.; Noirot, J.

    2008-07-15

    MAIA is a thermo-mechanical code dedicated to the modeling of MTR fuel plates. The main physical phenomena modeled in the code are the cladding oxidation, the interaction between fuel and Al-matrix, the swelling due to fission products and the Al/fuel particles interaction. The creeping of the plate can be modeled in the mechanical calculation. MAIA has been validated on U-Mo dispersion fuel experiments such as IRIS 1 and 2 and FUTURE. The results are in rather good agreement with post-irradiation examinations. MAIA can also be used to calculate in-pile behavior of U{sub 3}Si{sub 2} plates as in the SHARE experiment irradiated in the SCK/Mol BR2 reactor. The main outputs given by MAIA throughout the irradiation are temperatures, cladding oxidation thickness, interaction thickness, volume fraction of meat constituents, swelling, displacements, strains and stresses. MAIA is originally a two-dimensional code but a three-dimensional version is currently under development. (author)

  17. 24 CFR 3280.5 - Data plate.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 24 Housing and Urban Development 5 2014-04-01 2014-04-01 false Data plate. 3280.5 Section 3280.5... MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS General § 3280.5 Data plate. Each manufactured home shall bear a data plate affixed in a permanent manner near the main electrical panel or other...

  18. 24 CFR 3280.5 - Data plate.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 24 Housing and Urban Development 5 2012-04-01 2012-04-01 false Data plate. 3280.5 Section 3280.5... MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS General § 3280.5 Data plate. Each manufactured home shall bear a data plate affixed in a permanent manner near the main electrical panel or other...

  19. 24 CFR 3280.5 - Data plate.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 24 Housing and Urban Development 5 2011-04-01 2011-04-01 false Data plate. 3280.5 Section 3280.5... MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS General § 3280.5 Data plate. Each manufactured home shall bear a data plate affixed in a permanent manner near the main electrical panel or other...

  20. 24 CFR 3280.5 - Data plate.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 24 Housing and Urban Development 5 2013-04-01 2013-04-01 false Data plate. 3280.5 Section 3280.5... MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS General § 3280.5 Data plate. Each manufactured home shall bear a data plate affixed in a permanent manner near the main electrical panel or other...

  1. 24 CFR 3280.5 - Data plate.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Data plate. 3280.5 Section 3280.5... MANUFACTURED HOME CONSTRUCTION AND SAFETY STANDARDS General § 3280.5 Data plate. Each manufactured home shall bear a data plate affixed in a permanent manner near the main electrical panel or other...

  2. Moving Divertor Plates in a Tokamak

    SciTech Connect

    S.J. Zweben, H. Zhang

    2009-02-12

    Moving divertor plates could help solve some of the problems of the tokamak divertor through mechanical ingenuity rather than plasma physics. These plates would be passively heated on each pass through the tokamak and cooled and reprocessed outside the tokamak. There are many design options using varying plate shapes, orientations, motions, coatings, and compositions.

  3. Recent plate motions and crustal deformation

    SciTech Connect

    Lisowski, M. )

    1991-01-01

    Reports by U.S. workers on geodetic measurements of recent plate motions or crustal deformation published in 1987-1990 are reviewed. The review begins with global plate motions, proceeds through plate boundaries in California, Alaska, and the Pacific Northwest, and finishes with volcanic phenomena, monument stability and longevity, and GPS relative position measurements. 184 refs.

  4. 49 CFR 213.123 - Tie plates.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Tie plates. 213.123 Section 213.123 Transportation... TRANSPORTATION TRACK SAFETY STANDARDS Track Structure § 213.123 Tie plates. (a) In Classes 3 through 5 track where timber crossties are in use there shall be tie plates under the running rails on at least eight...

  5. 46 CFR 169.665 - Name plates.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Name plates. 169.665 Section 169.665 Shipping COAST... Gross Tons § 169.665 Name plates. Each generator, motor and other major item f power equipment must be provided with a name plate indicating the manufacturer's name, its rating in volts and amperes or in...

  6. 46 CFR 169.665 - Name plates.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Name plates. 169.665 Section 169.665 Shipping COAST... Gross Tons § 169.665 Name plates. Each generator, motor and other major item f power equipment must be provided with a name plate indicating the manufacturer's name, its rating in volts and amperes or in...

  7. 46 CFR 169.665 - Name plates.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Name plates. 169.665 Section 169.665 Shipping COAST... Gross Tons § 169.665 Name plates. Each generator, motor and other major item f power equipment must be provided with a name plate indicating the manufacturer's name, its rating in volts and amperes or in...

  8. 46 CFR 169.665 - Name plates.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Name plates. 169.665 Section 169.665 Shipping COAST... Gross Tons § 169.665 Name plates. Each generator, motor and other major item f power equipment must be provided with a name plate indicating the manufacturer's name, its rating in volts and amperes or in...

  9. 46 CFR 169.665 - Name plates.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Name plates. 169.665 Section 169.665 Shipping COAST... Gross Tons § 169.665 Name plates. Each generator, motor and other major item f power equipment must be provided with a name plate indicating the manufacturer's name, its rating in volts and amperes or in...

  10. Forming Weld Lands On Metal Plates

    NASA Technical Reports Server (NTRS)

    Weddendorf, Bruce

    1994-01-01

    Forming shoe pounds edge of newly inserted plate workpiece. After many passes of shoe and advances of plate, thick land builds up at edge. Workpiece heated to enable metal to flow without strain hardening. Proposed upset-forming process replaces relatively expensive, time-consuming, and wasteful process in which integral weld lands created by machining metal away from plates everywhere except at lands.

  11. 21 CFR 872.4760 - Bone plate.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Bone plate. 872.4760 Section 872.4760 Food and... DENTAL DEVICES Surgical Devices § 872.4760 Bone plate. (a) Identification. A bone plate is a metal device intended to stabilize fractured bone structures in the oral cavity. The bone segments are attached to...

  12. FASTENER FOR AN ASSEMBLY OF PLATES

    DOEpatents

    Groh, E.F.

    1963-08-20

    A fastener is provided for a spaced-apart parallel plate fuel assembly. The fastener, attached by screws to a key that passes through the edges of the assembled plate, serves as a retainer for the outermost plate as well as a bidirectional spacer for separating the fuel assembly from two neighboring fuel assemblies. (AEC)

  13. Normal-Pressure Tests of Rectangular Plates

    NASA Technical Reports Server (NTRS)

    Ramberg, Walter; Mcpherson, Albert E; Levy, Samuel

    1942-01-01

    Report presents the results of normal-pressure tests made of 56 rectangular plates with clamped edges and of 5 plates with freely supported edges. Pressure was applied and the center deflection and the permanent set at the center were measured. For some of the plates, in addition, strains and contours were measured.

  14. 21 CFR 872.4760 - Bone plate.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Bone plate. 872.4760 Section 872.4760 Food and... DENTAL DEVICES Surgical Devices § 872.4760 Bone plate. (a) Identification. A bone plate is a metal device intended to stabilize fractured bone structures in the oral cavity. The bone segments are attached to...

  15. The critical shear load of rectangular plates

    NASA Technical Reports Server (NTRS)

    Seydel, Edgar

    1933-01-01

    This report gives formulas for analyzing the critical shear load of a simply supported square, isotropic (simple flat plate), or orthogonal anisotropic plate (a plate in which the rigidity in two directions perpendicular to each other is different, i.e. plywood or corrugated sheet), these formulas, although arrived at by approximation method, seem to agree fairly well with experimental results.

  16. Apparatus and method for controlling plating uniformity

    DOEpatents

    Hachman Jr., John T.; Kelly, James J.; West, Alan C.

    2004-10-12

    The use of an insulating shield for improving the current distribution in an electrochemical plating bath is disclosed. Numerical analysis is used to evaluate the influence of shield shape and position on plating uniformity. Simulation results are compared to experimental data for nickel deposition from a nickel--sulfamate bath. The shield is shown to improve the average current density at a plating surface.

  17. 49 CFR 451.23 - Plate specifications.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 6 2011-10-01 2011-10-01 false Plate specifications. 451.23 Section 451.23 Transportation Other Regulations Relating to Transportation (Continued) COAST GUARD, DEPARTMENT OF HOMELAND SECURITY SAFETY APPROVAL OF CARGO CONTAINERS TESTING AND APPROVAL OF CONTAINERS Safety Approval Plate § 451.23 Plate specifications. (a) The...

  18. Development and testing of a multiwell plates absorbance reader for clinical analysis using inexpensive webcam

    NASA Astrophysics Data System (ADS)

    Castillo, Jimmy; Gutierrez, Hector; Vitta, Yosmery; Martinez, Mauro; Fernandez, Alberto

    2007-09-01

    Biochemical analysis and clinical tests like glucose, hemoglobin, cholesterol, iron, etc. are crucial for early illness diagnosis like diabetes, anemia and coronary deceases. These tests usually are done in state of the art instruments in well equipped laboratories in health centers. In some cases, these instruments are not portable, so they are not recommended for clinical field studies in remote areas. The present work shows a portable low-cost prototype of multi-well plates reader designed for clinical analysis. A Light Emission Diodes (LEDs) array is used as excitation source and an inexpensive webcam as detector. The light source illuminates the 96 well plates and the webcam take the image with 640x480 pixels. The data is acquired and processed by using a portable computer. 96 samples can be read including blanks and calibration standards simultaneously. Light absorption data are processed using a MatLab software designed in our laboratory to obtain calibration curves, standards lectures and samples concentration. The system was evaluated using different analytes series solutions: Neutral Red, Cooper (II) Ammonia Complex and Methyl Orange. The results shows that it is possible to measure few micro liters of solutions with adequate exactitude and precision of less than 3%. As possible analytical clinical application, iron determination was performed using Fe(III) Thiocyanate complex. This method is usually applied in serum samples analysis. The sensibility achieved with the proposed instrumentation configurations allows the analysis of iron in serum samples in the references values normal range (0.75 - 1.5 mg/L) in human.

  19. Plate tectonics, habitability and life

    NASA Astrophysics Data System (ADS)

    Spohn, Tilman; Breuer, Doris

    2016-04-01

    The role of plate tectonics in defining habitability of terrestrial planets is being increasingly discussed (e.g., Elkins-Tanton, 2015). Plate tectonics is a significantly evolved concept with a large variety of aspects. In the present context, cycling of material between near surface and mantle reservoirs is most important. But increased heat transport through mixing of cold lithosphere with the deep interior and formation of continental crust may also matter. An alternative mechanism of material cycling between these reservoirs is hot-spot volcanism combined with crust delamination. Hot-spot volcanism will transport volatiles to the atmosphere while delamination will mix crust, possibly altered by sedimentation and chemical reactions, with the mantle. The mechanism works as long as the stagnant lithosphere plate has not grown thicker than the crust and as long as volcanic material is added onto the crust. Thermal evolution studies suggest that the mechanism could work for the first 1-2 Ga of planetary evolution. The efficiency of the mechanism is limited by the ratio of extrusive to intrusive volcanism, which is thought to be less than 0.25. Plate tectonics would certainly have an advantage by working even for more evolved planets. A simple, most-used concept of habitability requires the thermodynamic stability of liquid water on the surface of a planet. Cycling of CO2between the atmosphere, oceans and interior through subduction and surface volcanism is an important element of the carbonate-silicate cycle, a thermostat feedback cycle that will keep the atmosphere from entering into a runaway greenhouse. Calculations for a model Earth lacking plate tectonics but degassing CO2, N, and H2O to form a surface ocean and a secondary atmosphere (Tosi et al, 2016) suggest that liquid water can be maintained on the surface for 4.5Ga. The model planet would then qualify as habitable. It is conceivable that the CO2 buffering capability of its ocean together with silicate

  20. Peridinialean dinoflagellate plate patterns, labels and homologies

    USGS Publications Warehouse

    Edwards, L.E.

    1990-01-01

    Tabulation patterns for peridinialean dinoflagellate thecae and cysts have been traditionally expressed using a plate labelling system described by C.A. Kofoid in the early 1900's. This system can obscure dinoflagellate plate homologies and has not always been strictly applied. The plate-labelling system presented here introduces new series labels but incorporates key features and ideas from the more recently proposed systems of G.L. Eaton and F.J.R. Taylor, as modified by W.R. Evitt. Plate-series recognition begins with the cingulum (C-series) and proceeds from the cingulum toward the apex for the three series of the epitheca/epicyst and proceeds from the cingulum toward the antapex for the two series of the hypotheca/hypocyst. The epithecal/epicystal model consists of eight plates that touch the anterior margin of the cingulum (E-series: plates E1-E7, ES), seven plates toward the apex that touch the E-series plates (M-series: R, M1-M6), and up to seven plates near the apex that do not touch E-series plates (D-series: Dp-Dv). The hypothecal/hypocystal model consists of eight plates that touch the posterior margin of the cingulum (H-series: H1-H6,HR,HS) and three plates toward the antapex (T1-T3). Epithecal/epicystal tabulation patterns come in both 8- and 7- models, corresponding to eight and seven plates, respectively, in the E-series. Hypothecal/hypocystal tabulation patterns also come in both 8- and 7-models, corresponding to eight and seven plates, respectively, in the H-series. By convention, the 7-model epitheca/epicyst has no plates E1 and M1; the 7-model hypotheca/hypocyst has no plate H6. Within an 8-model or 7-model, the system emphasizes plates that are presumed to be homologous by giving them identical labels. I introduce the adjectives "monothigmate", "dithigmate," and "trithigmate" to designate plates touching one, two, and three plates, respectively, of the adjacent series. The term "thigmation" applies to the analysis of plate contacts between

  1. Development of flat-plate solar plate collector: Evaporator

    NASA Astrophysics Data System (ADS)

    Abramzon, B.; Yaron, I.

    1981-11-01

    In the present study the thermal performance of a flat plate solar collector is analyzed theoretically for the case in which the working fluid may undergo a phase change within the tubes of the collector. In addition to the common domestic applications, such a collector - evaporator may be used as a generator of vapors for the production of mechanical or electrical energy, e.g., solar water pumps, solar power stations, etc., as well as for solar - powered absorption refrigeration machines, distillation installations, etc.

  2. Separator plate for a fuel cell

    DOEpatents

    Petri, R.J.; Meek, J.; Bachta, R.P.; Marianowski, L.G.

    1996-04-02

    A separator plate is described for a fuel cell comprising an anode current collector, a cathode current collector and a main plate, the main plate disposed between the anode current collector and the cathode current collector. The anode current collector forms a flattened peripheral wet seal structure and manifold wet seal structure on the anode side of the separator plate and the cathode current collector forms a flattened peripheral wet seal structure and manifold wet seal structure on the cathode side of the separator plate. In this manner, the number of components required to manufacture and assemble a fuel cell stack is reduced. 9 figs.

  3. Separator plate for a fuel cell

    DOEpatents

    Petri, Randy J.; Meek, John; Bachta, Robert P.; Marianowski, Leonard G.

    1996-01-01

    A separator plate for a fuel cell comprising an anode current collector, a cathode current collector and a main plate, the main plate disposed between the anode current collector and the cathode current collector. The anode current collector forms a flattened peripheral wet seal structure and manifold wet seal structure on the anode side of the separator plate and the cathode current collector forms a flattened peripheral wet seal structure and manifold wet seal structure on the cathode side of the separator plate. In this manner, the number of components required to manufacture and assemble a fuel cell stack is reduced.

  4. Steady state response of unsymmetrically laminated plates

    SciTech Connect

    Hosokawa, Kenji; Kawashima, Katsuya; Sakata, Toshiyuki

    1995-11-01

    A numerical approach for analyzing the forced vibration problem of a symmetrically laminated FRP (fiber reinforced plastic) composite plate was proposed by the authors. In the present paper, this approach is modified for application to an unsymmetrically laminated FRP composite plate. Numerical calculations are carried out for the clamped antisymmetrically laminated rectangular and elliptical plates which are a kind of unsymmetrically laminated plate. Then,, the effects of the lamina material and the fiber orientation angle on the steady state response are discussed. Furthermore, it is investigated that what structural damping factor is most influenced on the steady state response of an antisymmetrically laminated plate.

  5. Shear deformation in thick auxetic plates

    NASA Astrophysics Data System (ADS)

    Lim, Teik-Cheng

    2013-08-01

    This paper aims to understand the effect of auxeticity on shear deformation in thick plates. Three models for the shear correction factor of plates as a function of Poisson’s ratio were proposed: an analytical model, a cubic fit model and a modified model. Of these three, the cubic fit model exhibits the best accuracy over the entire range of Poisson’s ratio from -1 to 0.5. The extent of shear deformation is herein investigated using the example of uniformly loaded circular plates. It was found that the maximum deformation of such plates based on Mindlin theory approximates to those according to Kirchhoff theory when the Poisson’s ratio of the plate material is highly negative. When the Poisson’s ratio of the plate material is -1 and the edge of the plate is simply supported, the calculation of the maximum deflection by Mindlin theory simplifies into that by Kirchhoff theory. These results suggest that auxeticity reduces shear deformation in thick plates, permitting the use of classical plate theory for thick plates only if the plate material is highly auxetic.

  6. Characterization of gas-liquid mass transfer phenomena in microtiter plates.

    PubMed

    Hermann, Robert; Lehmann, Mathias; Büchs, Jochen

    2003-01-20

    Gas-liquid mass transfer properties of shaken 96-well microtiter plates were characterized using a recently described method. The maximum oxygen transfer capacity (OTR(max)), the specific mass transfer area (a), and the mass transfer coefficient (k(L)) in a single well were determined at different shaking intensities (different shaking frequencies and shaking diameters at constant filling volume) and different filling volumes by means of sulfite oxidation as a chemical model system. The shape (round and square cross-sections) and the size (up to 2 mL maximum filling volume) of a microtiter plate well were also considered as influencing parameters. To get an indication of the hydrodynamic behavior of the liquid phase in a well, images were taken during shaking and the liquid height derived as a characteristic parameter. The investigations revealed that the OTR(max) is predominantly dependent on the specific mass transfer area (a) for the considered conditions in round-shaped wells. The mass transfer coefficient (k(L)) in round-shaped wells remains at a nearly constant value of about 0.2 m/h for all shaking intensities, thus within the range reported in the literature for surface-aerated bioreactors. The OTR(max) in round-shaped wells is strongly influenced by the interfacial tension, determined by the surface tension of the medium used and the surface properties of the well material. Up to a specific shaking intensity the liquid surface in the wells remains horizontal and no liquid movement can be observed. This critical shaking intensity must be exceeded to overcome the surface tension and, thus, to increase the liquid height and enlarge the specific mass transfer area. This behavior is solely specific to microtiter plates and has not yet been observed for larger shaking bioreactors such as shaking flasks. In square-shaped microtiter plate wells the corners act as baffles and cause a significant increase of OTR(max), a, and k(L). An OTR(max) of up to 0.15 mol

  7. An understanding of HSLA-65 plate steels

    NASA Astrophysics Data System (ADS)

    Sampath, K.

    2006-02-01

    HSLA-65 plate steels can be produced using one of five plate manufacturing techniques: normalizing, controlled rolling (CR), controlled rolling followed by accelerated cooling (CR-AC), direct quenching and tempering (DQT), or conventional quenching and tempering (Q&T). The HSLA-65 steels are characterized by low carbon content and low alloy content, and they exhibit a low carbon equivalent that allows improved plate weldability. These characteristics in turn (a) provide the steel plate with a refined microstructure that ensures high strength and toughness; (b) eliminate or substantially reduce the need for preheating during welding; (c) resist susceptibility to hydrogen-assisted cracking (HAC) in the weld heat affected zone (HAZ) when fusion (arc) welded using low heat-input conditions; and (d) depending on section thickness, facilitate high heat-input welding (about 2 kJ/mm) without significant loss of strength or toughness in the HAZ. However, application of this plate manufacturing process and of these controls produces significant differences in the metallurgical structure and range of mechanical properties of the HSLA-65 plate steels both among themselves and versus conventional higher strength steel (HSS) plates. For example, among the HSLA-65 plate steels, those produced by Q&T exhibit minimal variability in mechanical properties, especially in thicker plates. Besides variability in mechanical properties depending on plate thickness, the CR and CR-AC plate steels exhibit a relatively higher yield strength to ultimate tensile strength (YS/UTS) ratio than do DQT and Q&T steels. Such differences in processing and properties of HSLA-65 plate steels could potentially affect the selection and control of various secondary fabrication practices, including arc welding. Consequently, fabricators must exercise extreme caution when transferring allowable limits of certified secondary fabrication practices from one type of HSLA-65 plate steel to another, even for the

  8. When Did Plate Tectonics Begin

    NASA Astrophysics Data System (ADS)

    Brown, M.

    2015-12-01

    Present-day plate tectonics on Earth is characterized by asymmetric (one-sided) subduction, but how do we recognize the imprint of subduction in the geologic record? How do we weigh global (commonly younger) vs local (commonly older) datasets or distinguish initiation from episodic from continuous subduction? How reliable are data gaps? Characteristics of the Paleozoic record of subduction include calc-alkaline magmatism, blueschist/UHP metamorphism and collisional orogenesis, and ophiolites as representatives of former ocean lithosphere. Are these characteristic rocks preserved in Proterozoic, Archean and Hadean crust? Does a hotter mantle, higher heat production and weaker lithosphere modify or eliminate these features? What preceded subduction and how do we recognize that regime? Are rock associations or geochemical fingerprints reliable? Does reworking and overprinting modify geochemical fingerprints? Proposals for the start of plate tectonics have been based on: persistence of isotope anomalies/fractionated chemical domains in the mantle; changes in chemistry of magmatic rocks, rates of crustal growth vs reworking, and sites of growth; the metamorphic record, particularly the first appearance of contrasting thermal gradients or eclogite (including evidence from mineral inclusions in diamonds) or UHP metamorphic rocks; stabilization of cratonic lithosphere and formation of supercratons, and the beginning of the Proterozoic supercontinent cycle; the end of the flat Earth, emergence of continents, development of significant topography, changes in the style of orogeny and the rise in atmospheric oxygen; and, the appearance of passive margins and changes in the style of sedimentation. Estimates of the timing have varied from the Hadean to Neoproterozoic. I will summarize evidence for a growing consensus that the late Mesoarchean to early Paleoproterozoic was a 700 Myr long period of transition to continuous (?) subduction and global (?) mobile-lid plate tectonics.

  9. Tectonic speed limits from plate kinematic reconstructions

    NASA Astrophysics Data System (ADS)

    Zahirovic, Sabin; Müller, R. Dietmar; Seton, Maria; Flament, Nicolas

    2015-05-01

    The motion of plates and continents on the planet's surface are a manifestation of long-term mantle convection and plate tectonics. Present-day plate velocities provide a snapshot of this ongoing process, and have been used to infer controlling factors on the speeds of plates and continents. However, present-day velocities do not capture plate behaviour over geologically representative periods of time. To address this shortcoming, we use a plate tectonic reconstruction approach to extract time-dependent plate velocities and geometries from which root mean square (RMS) velocities are computed, resulting in a median RMS plate speed of ∼ 4 cm /yr over 200 Myr. Linking tectonothermal ages of continental lithosphere to the RMS plate velocity analysis, we find that the increasing portions of plate area composed of continental and/or cratonic lithosphere significantly reduces plate speeds. Plates with any cratonic portion have a median RMS velocity of ∼ 5.8 cm /yr, while plates with more than 25% of cratonic area have a median RMS speed of ∼ 2.8 cm /yr. The fastest plates (∼ 8.5 cm /yr RMS speed) have little continental fraction and tend to be bounded by subduction zones, while the slowest plates (∼ 2.6- 2.8 cm /yr RMS speed) have large continental fractions and usually have little to no subducting part of plate perimeter. More generally, oceanic plates tend to move 2-3 times faster than continental plates, consistent with predictions of numerical models of mantle convection. The slower motion of continental plates is compatible with deep keels impinging on asthenospheric flow and increasing shear traction, thus anchoring the plate in the more viscous mantle transition zone. We also find that short-lived (up to ∼ 10 Myr) rapid accelerations of Africa (∼100 and 65 Ma), North America (∼100 and 55 Ma) and India (∼ 130 , 80 and 65 Ma) appear to be correlated with plume head arrivals as recorded by large igneous province (LIPs) emplacement. By evaluating

  10. Turbulent flows near flat plates

    NASA Astrophysics Data System (ADS)

    Kambe, R.; Imamura, T.; Doi, M.

    1980-08-01

    The method to study the effect of the plate moving in the homogeneous or isotropic turbulence is presented. The crucial point of this method is to solve the Orr-Sommerfeld like equation, which is satisfied by the kernel of the Wiener-Hermite expansion of the velocity field, under the inhomogeneous boundary condition. In the special case of constant mean flow, our method gives the same result as that of Hunt and Graham and succeeds in explaining the experimental results of Thomas and Hancock. The method is also applied to the case of nonuniform mean flow, where the shear effect comes up.

  11. Non-cyanide silver plating

    SciTech Connect

    Dini, J.W.

    1995-11-07

    Lawrence Livermore National Laboratory (LLNL) and Technic, Inc. have entered into a CRADA (Cooperative Research and Development Agreement) with the goal of providing industry with an environmentally benign alternative to the presently used silver cyanide plating process. This project has been in place for about six months and results are quite promising. The main objective, that of deposition of deposits as thick as 125 um (5 mils), has been met. Property data such as stress and hardness have been obtained and the structure of the deposit has been analyzed via metallography and x-ray diffraction. These results will be presented in this paper, along with plans for future work.

  12. Coarse Layering at 'Home Plate'

    NASA Technical Reports Server (NTRS)

    2006-01-01

    This image shows coarse-grained layers from around the edge of a low plateau called 'Home Plate' inside Mars' Gusev Crater. One possible origin is material falling to the ground after being thrown aloft by an explosion such as a volcanic eruption or meteorite impact.

    The panoramic camera (Pancam) on NASA's Mars Exploration Rover Spirit acquired the exposures for this image on Spirit's 749th Martian day (Feb. 10, 2006). This view is an approximately true-color rendering mathematically generated from separate images taken through all of the left Pancam's 432-nanometer to 753-nanometer filters.

  13. Adherent protective coatings plated on magnesium-lithium alloy

    NASA Technical Reports Server (NTRS)

    1965-01-01

    Zinc is plated on a magnesium-lithium alloy by using a modification of the standard zinc-plate immersion bath. Further protection is given the alloy by applying a light plating of copper on the zinc plating. Other metals are plated on the copper by using conventional plating baths.

  14. A Refined Shear Deformation Plate Theory

    NASA Astrophysics Data System (ADS)

    Liu, Yucheng

    2011-04-01

    An improved higher-order shear deformation theory of plates is presented in this paper. The theory is developed from the transverse shear deformation theory presented by Ambartsumian [11]. The present plate theory contains kinematics of higher-order displacement field of plates, a system of higher-order differential equilibrium equations in terms of the three generalized displacements of bending plates, and a system of boundary conditions at each edge of plate boundaries. The present shear deformation theory of plates is validated by applying it to solve torsional plates and simply supported plates. The obtained solutions using the present theory are compared with the solutions of other shear-deformation theories. A good agreement is achieved through these comparisons and the advantages of the present theory are clearly verified. The shear deformation plate theory presented here can be applied to the analysis of laminated composite plates to better predict their dynamic and static behaviors. The proposed theory should also be supplemented to the theory of finite element analysis for developing new shell elements.

  15. Analysis of plate spin motion and its implications for strength of plate boundary

    NASA Astrophysics Data System (ADS)

    Matsuyama, Takeshi; Iwamori, Hikaru

    2016-02-01

    In this study, we investigate the driving forces of plate motion, especially those of plate spin motion, that are related to the toroidal components of the global plate velocity field. In previous works, numerical simulations of mantle convection have been used to examine the extent to which toroidal velocity components are naturally generated on the surface, by varying key parameters, notably the rheological properties of plates and plate boundaries. Here, we take the reverse approach and perform analyses of observed plate motions, which show an increase in the toroidal/poloidal ratio at high degrees of spherical harmonic expansion, as well as a rapid change in the plate spin rate and the estimated driving stress around a critical plate size of approximately 1000 km. This quantitative relationship constrains the strength at plate boundaries to 3-75 MPa, which is consistent with several seismological observations, including those from the NE Japan arc associated with the 2011 Tohoku earthquake.

  16. Wide-Field Plate Database

    NASA Astrophysics Data System (ADS)

    Tsvetkov, M. K.; Stavrev, K. Y.; Tsvetkova, K. P.; Semkov, E. H.; Mutatov, A. S.

    The Wide-Field Plate Database (WFPDB) and the possibilities for its application as a research tool in observational astronomy are presented. Currently the WFPDB comprises the descriptive data for 400 000 archival wide field photographic plates obtained with 77 instruments, from a total of 1 850 000 photographs stored in 269 astronomical archives all over the world since the end of last century. The WFPDB is already accessible for the astronomical community, now only in batch mode through user requests sent by e-mail. We are working on on-line interactive access to the data via INTERNET from Sofia and parallel from the Centre de Donnees Astronomiques de Strasbourg. (Initial information can be found on World Wide Web homepage URL http://www.wfpa.acad.bg.) The WFPDB may be useful in studies of a variety of astronomical objects and phenomena, andespecially for long-term investigations of variable objects and for multi-wavelength research. We have analysed the data in the WFPDB in order to derive the overall characteristics of the totality of wide-field observations, such as the sky coverage, the distributions by observation time and date, by spectral band, and by object type. We have also examined the totality of wide-field observations from point of view of their quality, availability and digitisation. The usefulness of the WFPDB is demonstrated by the results of identification and investigation of the photometrical behaviour of optical analogues of gamma-ray bursts.

  17. Petrologic implications of plate tectonics.

    PubMed

    Yoder, H S

    1971-07-30

    Petrologists can make significant contributions to the plate tectonic concept. Fixing the stability fields of the principal rock types involved will provide the limits of pressure and temperature of the various environments. Experimental determination of the partition coefficients of the trace elements will be helpful. Studies of the partial melting behavior of possible parental materials in the absence and presence of water, especially the undersaturated region, will contribute to the understanding of magma production. Experimental observations on the rheological properties of the peridotites below and just above the solidus will lead to a better evaluation of the convective mechanism. Measurement of the fundamental properties of rocks, such as the density of solids and liquids at high pressures and temperatures, would contribute to understanding the concepts of diapiric rise, magma segregation, and the low-velocity zone. Broader rock sampling of the oceanic areas of all environments will do much to define the petrologic provinces. The field petrologist specializing in the Paleozoic regions and Precambrian shields can contribute by examining those regions for old plate boundaries and devising new criteria for their recognition. PMID:17770454

  18. Current global plate kinematics from GPS (1995-2007) with the plate-consistent reference frame

    NASA Astrophysics Data System (ADS)

    Kogan, Mikhail G.; Steblov, Grigory M.

    2008-04-01

    We present the vectors of rotation of 10 major lithospheric plates, estimated from continuous GPS observations at 192 globally distributed stations; 71 stations were selected as representing stable plate regions. All days for the period 1995.0-2007.0 were included in the analysis. In contrast to previous GPS plate models, our model is independent of international terrestrial reference frames (ITRF). The origin of our plate-consistent reference frame is the center of plate rotation (CP) rather than the center of mass of the entire Earth's system (CM) as in recent versions of ITRF. We estimate plate rotations and CP by minimizing the misfit between the horizontal velocities predicted by the plate model and the observed GPS velocities. If any version of ITRF is used as the reference frame, the drift of the ITRF origin relative to CP cannot be neglected in estimation of plate rotation vectors and plate-residual station velocities. The model of the plate kinematics presented here addresses the problem debated since the beginning of the space geodesy: how big are disagreements between the current plate motions and the motions averaged over several million years? We compare the vectors of relative plate rotations estimated here with the published vectors from GPS and geologic models. We also discuss the integrity of individual plates as exhibited by plate-residual station velocities. For seven largest plates, the RMS value of plate-residual station velocities in stable plate interiors is 0.5-0.9 mm/a; this value is an upper bound on deviation of real plates from infinite stiffness.

  19. Effect of plate roughness on the field near RPC plates

    NASA Astrophysics Data System (ADS)

    Jash, A.; Majumdar, N.; Mukhopadhyay, S.; Chattopadhyay, S.

    2016-06-01

    The inner surfaces of the electrodes encompassing the gas volume of a Resistive Plate Chamber (RPC) have been found to exhibit asperities with, grossly, three kind of features. The desired uniform electric field within the gas volume of RPC is expected to be affected due to the presence of these asperities, which will eventually affect the final response from the detector. In this work, an attempt has been made to model the highly complex roughness of the electrode surfaces and compute its effect on the electrostatic field within RPC gas chamber. The calculations have been performed numerically using Finite Element Method (FEM) and Boundary Element Method (BEM) and the two methods have been compared in this context.

  20. Droplet-based magnetic bead immunoassay using microchannel-connected multiwell plates (μCHAMPs) for the detection of amyloid beta oligomers.

    PubMed

    Park, Min Cheol; Kim, Moojong; Lim, Gun Taek; Kang, Sung Min; An, Seong Soo A; Kim, Tae Song; Kang, Ji Yoon

    2016-06-21

    Multiwell plates are regularly used in analytical research and clinical diagnosis but often require laborious washing steps and large sample or reagent volumes (typically, 100 μL per well). To overcome such drawbacks in the conventional multiwell plate, we present a novel microchannel-connected multiwell plate (μCHAMP) that can be used for automated disease biomarker detection in a small sample volume by performing droplet-based magnetic bead immunoassay inside the plate. In this μCHAMP-based immunoassay platform, small volumes (30-50 μL) of aqueous-phase working droplets are stably confined within each well by the simple microchannel structure (200-300 μm in height and 0.5-1 mm in width), and magnetic beads are exclusively transported into an adjacent droplet through the oil-filled microchannels assisted by a magnet array aligned beneath and controlled by a XY-motorized stage. Using this μCHAMP-based platform, we were able to perform parallel detection of synthetic amyloid beta (Aβ) oligomers as a model analyte for the early diagnosis of Alzheimer's disease (AD). This platform easily simplified the laborious and consumptive immunoassay procedure by achieving automated parallel immunoassay (32 assays per operation in 3-well connected 96-well plate) within 1 hour and at low sample consumption (less than 10 μL per assay) with no cumbersome manual washing step. Moreover, it could detect synthetic Aβ oligomers even below 10 pg mL(-1) concentration with a calculated detection limit of ∼3 pg mL(-1). Therefore, the μCHAMP and droplet-based magnetic bead immunoassay, with the combination of XY-motorized magnet array, would be a useful platform in the diagnosis of human disease, including AD, which requires low consumption of the patient's body fluid sample and automation of the entire immunoassay procedure for high processing capacity. PMID:27185215

  1. Assay of creatine kinase in microtiter plates using thio-NAD to allow monitoring at 405 nM.

    PubMed

    Florini, J R

    1989-11-01

    An assay system for creatine kinase using microtiter plates and a plate reader that records absorbancies at 405 nM has been devised. The system is an adaptation of well-established assays that couple creatine kinase with the reactions catalyzed by hexokinase and glucose-6-phosphate dehydrogenase (G6PDH), to give a measurable increase in reduced pyridine nucleotide quantitated by absorbance at 340 nM. Two features of this system are modified for reading at 405 nM: (i) The thioamido derivative of NAD is used because its reduced form exhibits a substantial increase in absorbance at 405 nM, the most commonly available wavelength on microplate readers; and (ii) glucose-6-phosphate dehydrogenase from Leuconostoc mesenteroides is used because it can reduce either NAD or NADP (unlike most other G6PDH enzymes, which require NADP), thus making it unnecessary to use the more expensive thio-NADP. The rate of thio-NAD reduction is linear with enzyme concentration and time over a 20-fold range of concentrations of purified creatine kinase, and the assay also works well with myogenic cells allowed to grow and differentiate in the 96-well plate in which the assay is performed. This system offers considerable savings in cells, time, and material in studies of muscle cell differentiation, for which creatine kinase levels are frequently measured. It also provides a potential method for the convenient and economical measurement of activities of many other enzymes that can be coupled to reduction of thio-NAD. PMID:2610356

  2. Battery plate containing filler with conductive coating

    NASA Technical Reports Server (NTRS)

    Rowlette, John J. (Inventor)

    1986-01-01

    The plate (10) comprises a matrix or binder resin phase (12) in which is dispersed particulate, conductive tin oxide such as tin oxide coated glass fibers (14). A monopolar plate (11) is prepared by coating a layer (18) of electrolytically active material onto a surface of the plate (10). Tin oxide is prevented from reduction by coating a surface of the plate (10) with a conductive, impervious layer resistant to reduction such as a thin film (22) of lead adhered to the plate with a layer (21) of conductive adhesive. The plate (10) can be formed by casting a molten dispersion from mixer (36) onto a sheet (30) of lead foil or by passing an assembly of a sheet (41) of resin, a sheet (43) of fiberglass and a sheet (45) of lead between the nip of heated rollers (48, 50).

  3. Battery plate containing filler with conductive coating

    NASA Technical Reports Server (NTRS)

    Rowlette, John J. (Inventor)

    1985-01-01

    The plate (10) comprises a matrix or binder resin phase (12) in which is dispersed particulate, conductive tin oxide such as tin oxide coated glass fibers (14). A monopolar plate (11) is prepared by coating a layer (18) of electrolytically active material onto a surface of the plate (10). Tin oxide is prevented from reduction by coating a surface of the plate (10) with a conductive, impervious layer resistant to reduction such as a thin film (22) of lead adhered to the plate with a layer (21) of conductive adhesive. The plate (10) can be formed by casting a molten dispersion from mixer (36) onto a sheet (30) of lead foil or by passing an assembly of a sheet (41) of resin, a sheet (43) of fiberglass and a sheet (45) of lead between the nip of heated rollers (48, 50).

  4. Excitation and Characterization of Chladni Plate Patterns

    NASA Astrophysics Data System (ADS)

    Bourke, Shannon; Behringer, Ernest

    2011-04-01

    When a thin metal plate with a small amount of sand on it is made to vibrate, aesthetically pleasing sand patterns can form along the nodal lines of the plate. These symmetric patterns are called Chladni Patterns. Students taking PHY 101 Physical Science in the Arts at Eastern Michigan University create these patterns by pulling a violin bow across the edge of a plate, or by using a mechanical oscillator to drive the center of a plate. These two methods only allow a small subset of all possible points on the plate to be excited. We designed and built an electronic device that allows its user to excite the plate at any point. We present patterns created with this electronic device and other methods, and describe ways to model the observed patterns.

  5. Membrane- and plate-type acoustic metamaterials.

    PubMed

    Huang, Tai-Yun; Shen, Chen; Jing, Yun

    2016-06-01

    Over the past decade there has been a great amount of research effort devoted to the topic of acoustic metamaterials (AMMs). The recent development of AMMs has enlightened the way of manipulating sound waves. Several potential applications such as low-frequency noise reduction, cloaking, angular filtering, subwavelength imaging, and energy tunneling have been proposed and implemented by the so-called membrane- or plate-type AMMs. This paper aims to offer a thorough overview on the recent development of membrane- or plate-type AMMs. The underlying mechanism of these types of AMMs for tuning the effective density will be examined first. Four different groups of membrane- or plate-type AMMs (membranes with masses attached, plates with masses attached, membranes or plates without masses attached, and active AMMs) will be reviewed. The opportunities, limitations, and challenges of membrane- or plate-type AMMs will be also discussed. PMID:27369148

  6. Rapidly Moving Divertor Plates In A Tokamak

    SciTech Connect

    S. Zweben

    2011-05-16

    It may be possible to replace conventional actively cooled tokamak divertor plates with a set of rapidly moving, passively cooled divertor plates on rails. These plates would absorb the plasma heat flux with their thermal inertia for ~10-30 sec, and would then be removed from the vessel for processing. When outside the tokamak, these plates could be cooled, cleaned, recoated, inspected, and then returned to the vessel in an automated loop. This scheme could provide nearoptimal divertor surfaces at all times, and avoid the need to stop machine operation for repair of damaged or eroded plates. We describe various possible divertor plate designs and access geometries, and discuss an initial design for a movable and removable divertor module for NSTX-U.

  7. Coupling between plate vibration and acoustic radiation

    NASA Technical Reports Server (NTRS)

    Frendi, Abdelkader; Maestrello, Lucio; Bayliss, Alvin

    1992-01-01

    A detailed numerical investigation of the coupling between the vibration of a flexible plate and the acoustic radiation is performed. The nonlinear Euler equations are used to describe the acoustic fluid while the nonlinear plate equation is used to describe the plate vibration. Linear, nonlinear, and quasi-periodic or chaotic vibrations and the resultant acoustic radiation are analyzed. We find that for the linear plate response, acoustic coupling is negligible. However, for the nonlinear and chaotic responses, acoustic coupling has a significant effect on the vibration level as the loading increases. The radiated pressure from a plate undergoing nonlinear or chaotic vibrations is found to propagate nonlinearly into the far-field. However, the nonlinearity due to wave propagation is much weaker than that due to the plate vibrations. As the acoustic wave propagates into the far-field, the relative difference in level between the fundamental and its harmonics and subharmonics decreases with distance.

  8. Real time monitoring of electroless nickel plating

    NASA Astrophysics Data System (ADS)

    Rains, Aaron E.; Kline, Ronald A.

    2013-01-01

    This work deals with the design and manufacturing of the heat and chemical resistant transducer case required for on-line immersion testing, experimental design, data acquisition and signal processing. Results are presented for several depositions with an accuracy of two ten-thousandths of an inch in coating thickness obtained. Monitoring the deposition rate of Electroless Nickel (EN) plating in-situ will provide measurement of the accurate dimensions of the component being plated, in real time. EN is used as for corrosion and wear protection for automotive an - Electroless Nickel (EN) plating is commonly used for corrosion and wear protection for automotive and aerospace components. It plates evenly and symmetrically, theoretically allowing the part to be plated to its final dimension. Currently the standard approach to monitoring the thickness of the deposited nickel is to remove the component from the plating bath and physically measure the part. This can lead to plating problems such as pitting, non-adhesion of the deposit and contamination of the plating solution. The goal of this research effort is to demonstrate that plating thickness can be rapidly and accurately measured using ultrasonic testing. Here a special housing is designed to allow immersion of the ultrasonic transducers directly into the plating bath. An FFT based signal processing algorithm was developed to resolve closely spaced echoes for precise thickness determination. The technique in this research effort was found to be capable of measuring plating thicknesses to within 0.0002 inches. It is expected that this approach will lead to cost savings in many EN plating operations.

  9. High speed thin plate fatigue crack monitor

    NASA Technical Reports Server (NTRS)

    Wincheski, Buzz A. (Inventor); Heyman, Joseph S. (Inventor); Namkung, Min (Inventor); Fulton, James P. (Inventor)

    1996-01-01

    A device and method are provided which non-destructively detect crack length and crack geometry in thin metallic plates. A non-contacting vibration apparatus produces resonant vibrations without introducing extraneous noise. Resulting resonant vibration shifts in cracked plates are correlated to known crack length in plates with similar resonant vibration shifts. In addition, acoustic emissions of cracks at resonance frequencies are correlated to acoustic emissions from known crack geometries.

  10. Avionics Box Cold Plate Damage Prevention

    NASA Technical Reports Server (NTRS)

    Stambolian, Damon; Larcher, Steven; Henderson, Gena; Tran, Donald

    2011-01-01

    Over the years there have been several occurrences of damage to Space Shuttle Orbiter cold plates during removal and replacement of avionics boxes. Thus a process improvement team was put together to determine ways to prevent these kinds of damage. From this effort there were many solutions including, protective covers, training, and improved operations instructions. The focus of this paper is to explain the cold plate damage problem and the corrective actions for preventing future damage to aerospace avionics cold plate designs.

  11. Anisotropic magnetocapacitance in ferromagnetic-plate capacitors

    NASA Astrophysics Data System (ADS)

    Haigh, J. A.; Ciccarelli, C.; Betz, A. C.; Irvine, A.; Novák, V.; Jungwirth, T.; Wunderlich, J.

    2015-04-01

    The capacitance of a parallel-plate capacitor can depend on the applied magnetic field. Previous studies have identified capacitance changes induced via classical Lorentz force or spin-dependent Zeeman effects. Here we measure a magnetization direction-dependent capacitance in parallel-plate capacitors where one plate is a ferromagnetic semiconductor, gallium manganese arsenide. This anisotropic magnetocapacitance is due to the anisotropy in the density of states dependent on the magnetization through the strong spin-orbit interaction.

  12. Bipolar plates for PEM fuel cells

    NASA Astrophysics Data System (ADS)

    Middelman, E.; Kout, W.; Vogelaar, B.; Lenssen, J.; de Waal, E.

    The bipolar plates are in weight and volume the major part of the PEM fuel cell stack, and are also a significant contributor to the stack costs. The bipolar plate is therefore a key component if power density has to increase and costs must come down. Three cell plate technologies are expected to reach targeted cost price levels, all having specific advantages and drawbacks. NedStack has developed a conductive composite materials and a production process for fuel cell plates (bipolar and mono-polar). The material has a high electric and thermal conductivity, and can be processed into bipolar plates by a proprietary molding process. Process cycle time has been reduced to less than 10 s, making the material and process suitable for economical mass production. Other development work to increase material efficiency resulted in thin bipolar plates with integrated cooling channels, and integrated seals, and in two-component bipolar plates. Total thickness of the bipolar plates is now less than 3 mm, and will be reduced to 2 mm in the near future. With these thin integrated plates it is possible to increase power density up to 2 kW/l and 2 kW/kg, while at the same time reducing cost by integrating other functions and less material use.

  13. Plate Tectonics: A Paradigm under Threat.

    ERIC Educational Resources Information Center

    Pratt, David

    2000-01-01

    Discusses the challenges confronting plate tectonics. Presents evidence that contradicts continental drift, seafloor spreading, and subduction. Reviews problems posed by vertical tectonic movements. (Contains 242 references.) (DDR)

  14. Vibration of thin, tensioned, helically wrapped plates

    NASA Astrophysics Data System (ADS)

    Lopez, Ernesto; Müftü, Sinan

    2011-02-01

    Free vibration analysis of a thin tensioned plate, wrapped around a cylindrical guide in a helical manner is presented. The system is a model of a thin, flexible web wrapped around a turn-bar. The equation of motion of the wrapped plate is derived by using the energy method and with the Kirchhoff-Love assumptions. The weak form of the equation of motion was obtained by the finite element method and the eigenvalue problem was solved numerically. The effects of parameters such as plate tension, guide radius, longitudinal and helical wrap angles, plate width, and the lengths of the non-wrapped segments were investigated. Eigenmodes with same mode numbers were observed in symmetric and anti-symmetric fashion about the center of the plate, for symmetrically wrapped plates. It was shown that the plate/shell boundary of the wrapped plate effectively acts like a support. For non-helically wrapped plates the free edges cause a frequency clustering of the lateral modes about the dominant longitudinal mode. The frequency clustering diminishes when helical wrap is introduced.

  15. The floor plate: multiple cells, multiple signals.

    PubMed

    Placzek, Marysia; Briscoe, James

    2005-03-01

    One of the key organizers in the CNS is the floor plate - a group of cells that is responsible for instructing neural cells to acquire distinctive fates, and that has an important role in establishing the elaborate neuronal networks that underlie the function of the brain and spinal cord. In recent years, considerable controversy has arisen over the mechanism by which floor plate cells form. Here, we describe recent evidence that indicates that discrete populations of floor plate cells, with characteristic molecular properties, form in different regions of the neuraxis, and we discuss data that imply that the mode of floor plate induction varies along the anteroposterior axis. PMID:15738958

  16. Dynamic stiffness formulation for free orthotropic plates

    NASA Astrophysics Data System (ADS)

    Ghorbel, O.; Casimir, J. B.; Hammami, L.; Tawfiq, I.; Haddar, M.

    2015-06-01

    This paper presents a procedure for developing the dynamic stiffness matrix of a free orthotropic Kirchhoff plate. The dynamic stiffness matrix is computed for free edge boundary conditions of the plate that allow assembly procedures. The method is based on a strong formulation of Kirchhoff plate equations and series solutions, taking advantage of the symmetry and Gorman type decomposition of the free boundary conditions. The performances of the so-called Dynamic Stiffness Method (DSM) are evaluated by comparing the harmonic responses of an orthotropic Kirchhoff plate with those obtained from the Finite Element Method using four noded quadrilateral elements.

  17. Locomotion of a flapping flexible plate

    NASA Astrophysics Data System (ADS)

    Hua, Ru-Nan; Zhu, Luoding; Lu, Xi-Yun

    2013-12-01

    The locomotion of a flapping flexible plate in a viscous incompressible stationary fluid is numerically studied by an immersed boundary-lattice Boltzmann method for the fluid and a finite element method for the plate. When the leading-edge of the flexible plate is forced to heave sinusoidally, the entire plate starts to move freely as a result of the fluid-structure interaction. Mechanisms underlying the dynamics of the plate are elucidated. Three distinct states of the plate motion are identified and can be described as forward, backward, and irregular. Which state to occur depends mainly on the heaving amplitude and the bending rigidity of the plate. In the forward motion regime, analysis of the dynamic behaviors of the flapping flexible plate indicates that a suitable degree of flexibility can improve the propulsive performance. Moreover, there exist two kinds of vortex streets in the downstream of the plate which are normal and deflected wake. Further the forward motion is compared with the flapping-based locomotion of swimming and flying animals. The results obtained in the present study are found to be consistent with the relevant observations and measurements and can provide some physical insights into the understanding of the propulsive mechanisms of swimming and flying animals.

  18. Rapidly solidified metal coatings by peen plating

    NASA Technical Reports Server (NTRS)

    Chu, H. P.

    1987-01-01

    Specimens of 7075-T6 aluminum alloy were peen plated with rapidly solidified tin-lead and aluminum powders, and the cross-sections of the coated specimens were examined by light and electron microscopy. The properties of the peen plated specimens were also compared with those of shot peened specimens without any coating. It is found that peen plating with rapidly solidified metals improves the fatigue properties of the coated samples to a greater extent than shot peening alone. Specimens of 7075-T6 alloy peen plated with rapidly solidified tin-lead and aluminum exhibited better fatigue resistance than shot peened specimens in both air and salt water.

  19. MACMA: a Virtual Lab for Plate Tectonics

    NASA Astrophysics Data System (ADS)

    Grigne, C.; Combes, M.; Tisseau, C.

    2013-12-01

    MACMA (Multi-Agent Convective MAntle) is a tool developed to simulate evolutive plate tectonics and mantle convection in a 2-D cylindrical geometry (Combes et al., 2012). The model relies mainly on a force balance to compute the velocity of each plate, and on empirical rules to determine how plate boundaries move and evolve. It includes first-order features of plate tectonics: (a) all plates on Earth do not have the same size, (b) subduction zones are asymmetric, (c) plates driven by subducting slabs and upper plates do not exhibit the same velocities, and (d) plate boundaries are mobile, can collide, merge and disappear, and new plate boundaries can be created. The MACMA interface was designed to be user-friendly and a simple use of the simulator can be achieved without any prerequisite knowledge in fluid dynamics, mantle rheology, nor in numerical methods. As a preliminary study, the simulator was used by a few students from bachelor's degree to master's degree levels. An initial configuration for plate tectonics has to be created before starting a simulation: the number and types of plate boundaries (ridge, subduction, passive margins) has to be defined and seafloor ages must be given. A simple but interesting exercise consists in letting students build such an initial configuration: they must analyze a map of tectonic plates, choose a 2-D section and examine carefully a map of seafloor ages. Students mentioned that the exercise made them realize that the 3-D spherical structure of plate tectonics does not translate directly in a simple 2-D section, as opposed to what is usually shown in books. Physical parameters: e.g. mantle viscosity, number of layers to consider in the mantle (upper and lower mantle, possible asthenosphere), initial time and mantle temperature, have to be chosen, and students can use this virtual lab to see how different scenarios emerge when parameters are varied. Very importantly, the direct visualization of the mobility of plate

  20. Fuel cell cooler-humidifier plate

    DOEpatents

    Vitale, Nicholas G.; Jones, Daniel O.

    2000-01-01

    A cooler-humidifier plate for use in a proton exchange membrane (PEM) fuel cell stack assembly is provided. The cooler-humidifier plate combines functions of cooling and humidification within the fuel cell stack assembly, thereby providing a more compact structure, simpler manifolding, and reduced reject heat from the fuel cell. Coolant on the cooler side of the plate removes heat generated within the fuel cell assembly. Heat is also removed by the humidifier side of the plate for use in evaporating the humidification water. On the humidifier side of the plate, evaporating water humidifies reactant gas flowing over a moistened wick. After exiting the humidifier side of the plate, humidified reactant gas provides needed moisture to the proton exchange membranes used in the fuel cell stack assembly. The invention also provides a fuel cell plate that maximizes structural support within the fuel cell by ensuring that the ribs that form the boundaries of channels on one side of the plate have ends at locations that substantially correspond to the locations of ribs on the opposite side of the plate.

  1. Wave propagation in metamaterial lattice sandwich plates

    NASA Astrophysics Data System (ADS)

    Fang, Xin; Wen, Jihong; Yin, Jianfei; Yu, Dianlong

    2016-04-01

    This paper designed a special acoustic metamaterial 3D Kagome lattice sandwich plate. Dispersion properties and vibration responses of both traditional plate and metamaterial plate are investigated based on FEA methods. The traditional plate does not have low-frequency complete bandgaps, but the metamaterial plate has low-frequency complete bandgap (at 620Hz) coming from the symmetrical local cantilever resonators. The bandgap frequency is approximate to the first-order natural frequency of the oscillator. Complex wave modes are analyzed. The dispersion curves of longitudinal waves exist in the flexural bandgap. The dispersion properties demonstrate the metamaterial design is advantageous to suppress the low-frequency flexural wave propagation in lattice sandwich plate. The flexural vibrations near the bandgap are also suppressed efficiently. The longitudinal excitation stimulates mainly longitudinal waves and lots of low-frequency flexural vibration modes are avoided. Furthermore, the free edge effects in metamaterial plate provide new method for damping optimizations. The influences of damping on vibrations of the metamaterial sandwich plate are studied. Damping has global influence on the wave propagation; stronger damping will induce more vibration attenuation. The results enlighten us damping and metamaterial design approaches can be unite in the sandwich plates to suppress the wave propagations.

  2. Modal interaction in postbuckled plates. Theory

    NASA Technical Reports Server (NTRS)

    Thurston, Gaylen A.

    1989-01-01

    Plates can have more than one buckled solution for a fixed set of boundary conditions. The theory for the identification and the computation of multiple solutions in buckled plates is examined. The theory predicts modal interaction (which is also called change in buckle pattern or secondary buckling) in experiments on certain plates with multiple theoretical solutions. A set of coordinate functions is defined for Galerkin's method so that the von Karman plate equations are reduced to a coupled set of cubic equations in generalized coordinates that are uncoupled in the linear terms. An iterative procedure for solving modal interaction problems is suggested based on this cubic form.

  3. Tunable surface plasmon wave plates.

    PubMed

    Djalalian-Assl, Amir; Cadusch, Jasper J; Balaur, Eugeniu; Aramesh, Morteza

    2016-07-01

    The highest resonant transmission through an array of holes perforated in metallic screens occurs when the dielectric constant of the substrate, the superstrate, and the hole are the same. Changes in the refractive index of the homogenous environment also produce the largest shift in resonances per refractive index unit. In this Letter, we first propose and apply a technique in realization of a freestanding bi-periodic array of holes perforated in a silver film. We then show both numerically and experimentally that shifts in (1,0) and (0,1) modes in response to changes in the refractive index of the surrounding dielectric provide a mechanism for realization of a miniaturized tunable quarter-wave plate that operates in an extraordinary optical transmission mode with a high throughput and a near unity state of circularly polarized light. PMID:27367123

  4. Background events in microchannel plates

    NASA Technical Reports Server (NTRS)

    Siegmund, O. H. W.; Vallerga, J.; Wargelin, B.

    1988-01-01

    Measurements have been made to assess the characteristics and origins of background events in microchannel plates (MCPs). An overall background rate of about 0.4 events/sq cm persec has been achieved consistently for MCPs that have been baked and scrubbed. The temperature and gain of the MCPs are found to have no significant effect on the background rate. Detection of 1.46-MeV gamma rays from the MCP glass confirms the presence of K-40, with a concentration of 0.0007 percent, in MCP glass. It is shown that beta decay from K-40 is sufficient to cause the background rate and spectrum observed. Anticoincidence measurements indicate the the background rate caused by cosmic ray interactions is small (less than 0.016 events/sq cm per sec).

  5. A Treatise on Equivalent-Plate Stiffnesses for Stiffened Laminated-Composite Plates and Plate-Like Lattices

    NASA Technical Reports Server (NTRS)

    Nemeth, Michael P.

    2011-01-01

    A survey of studies conducted since 1914 on the use of equivalent-plate stiffnesses in modeling the overall, stiffness-critical response of stiffened plates and shells is presented. Two detailed, comprehensive derivations of first-approximation equivalent-plate stiffnesses are also presented that are based on the Reissner-Mindlin-type, first-order transverse-shear deformation theory for anisotropic plates. Equivalent-plate stiffness expressions, and a corresponding symbolic manipulation computer program, are also presented for several different stiffener configurations. These expressions are very general and exhibit the full range of anisotropies permitted by the Reissner-Mindlin-type, first-order transverse-shear deformation theory for anisotropic plates. The expressions presented in the present study were also compared with available, previously published results. For the most part, the previously published results are for special cases of the general expressions presented herein and are almost in complete agreement. Analysis is also presented that extends the use of the equivalent-plate stiffness expressions to sandwich plates.

  6. Thickness dependence of the Casimir force between a magnetodielectric plate and a diamagnetic plate

    SciTech Connect

    Inui, Norio

    2011-11-15

    This paper examines the repulsive Casimir force between a magnetodielectric plate, with static permeability greater than static permittivity, and a diamagnetic plate. As the thickness of the magnetodielectric plate is decreased, the attractive component of the Casimir force decreases more than the repulsive one. This effect makes the net Casimir force repulsive, and a larger repulsive Casimir force is generated compared to the Casimir force between the plates with infinite thickness.

  7. Evaluation of brush plated alloys as substitutes for tank plated hard chromium

    SciTech Connect

    Durham, H.B.; Hooper, A.M.

    1995-11-01

    This paper summarizes results obtained from a test program conducted in cooperation with Tinker Air Force Base (TAFB) in 1993 for the purpose of evaluating the potential of using brush plated alloys as replacements for tank plated hard chromium which is used in the overhaul of jet engines. Tank plating is energy expensive and generates waste products in several of the plating steps. Test specimens used in this study were fabricated from carbon steel, chromium-based stainless steel, and nickel-based stainless steel. Baseline specimens were tank plated with hard chromium or with a soft nickel capped with hard chromium. The specimens were tested for fatigue, thickness, microhardness, Taber wear, and Falex pin and vee block wear. All test were conducted in accordance with standard procedures of the American Society for Testing and Materials (ASTM). Test results obtained from the baseline specimens were compared with those obtained from specimens which had been coated with the three brush plated layered alloy solutions used in this evaluation. Results of this study show that brush plated alloy coatings appear promising as alternatives to tank plated hard chromium. Some data quality problems were encountered during testing, so at this time, definitive statements concerning the use of brush plating alloys as an acceptable alternative to tank plated hard chromium in critical TAFB maintenance, cannot be made. Although these tests results are not positive for TAFB`s operation, users of hard chromium tank plating with less critical applications may find brush plated coatings a suitable alternative. 1 ref.

  8. Simulation of Evolutive Plate Tectonics: the Size of Plates Depends on Mantle Temperature

    NASA Astrophysics Data System (ADS)

    Grigne, C.; Combes, M.

    2013-12-01

    We use a dynamic model of plate tectonics based on a multiagent approach, in a 2D cylindrical geometry (Combes et al., 2012), to study how evolutive plate tectonics affect the long term thermal state of the mantle, and in return, to analyze the relationship between the mantle mean temperature and the geometry of plate tectonics. Our model accounts for first-order features of plate tectonics: (a) all plates on Earth do not have the same size, (b) subduction zones are asymmetric, (c) plates driven by subducting slabs and upper plates do not exhibit the same velocities, and (d) plate boundaries are mobile, can collide, merge and disappear, and new plate boundaries can be created. We show that when processes for plate boundary creation (subduction initiation and ridge creation) are relying on a brittle criterion, namely when a fixed yield strength has to be reached, the average size of plates adapts to the mantle thermal state: longer plates are obtained for a hotter mantle, which implies a maximum seafloor age that remains fairly high throughout Earth's thermal history and limits mantle heat loss. This is consistent with petrological and geochemical constraints on Earth's cooling history. Important fluctuations in the mantle heat flux and velocities of plates are obtained on a timescale of a few hundred Myr, but on the long term, the relationship between the average wavelength of plate tectonics and mantle temperature can be explained by a simple scaling law. Recent compilations of geological records infer that passive margins had longer lifespans in the past (e.g. Bradley 2008; 2011), which has been linked to 'sluggish' plate tectonics and slow plates in the Precambrian (Korenaga, 2006). Our simulations outputs include lifespans of tectonic entities such as passive margins, as well as statistical data about events of plates reorganizations. We obtain faster plates in the past than at present day, but counterintuitively we also observe a low episodicity of tectonic

  9. Vacuum fusion bonding of glass plates

    DOEpatents

    Swierkowski, Steve P.; Davidson, James C.; Balch, Joseph W.

    2000-01-01

    An improved apparatus and method for vacuum fusion bonding of large, patterned glass plates. One or both glass plates are patterned with etched features such as microstructure capillaries and a vacuum pumpout moat, with one plate having at least one hole therethrough for communication with a vacuum pumpout fixture. High accuracy alignment of the plates is accomplished by a temporary clamping fixture until the start of the fusion bonding heat cycle. A complete, void-free fusion bond of seamless, full-strength quality is obtained through the plates; because the glass is heated well into its softening point and because of a large, distributed force that is developed that presses the two plates together from the difference in pressure between the furnace ambient (high pressure) and the channeling and microstructures in the plates (low pressure) due to the vacuum drawn. The apparatus and method may be used to fabricate microcapillary arrays for chemical electrophoresis; for example, any apparatus using a network of microfluidic channels embedded between plates of glass or similar moderate melting point substrates with a gradual softening point curve, or for assembly of glass-based substrates onto larger substrates, such as in flat panel display systems.

  10. Vacuum fusion bonding of glass plates

    DOEpatents

    Swierkowski, Steve P.; Davidson, James C.; Balch, Joseph W.

    2001-01-01

    An improved apparatus and method for vacuum fusion bonding of large, patterned glass plates. One or both glass plates are patterned with etched features such as microstructure capillaries and a vacuum pumpout moat, with one plate having at least one hole therethrough for communication with a vacuum pumpout fixture. High accuracy alignment of the plates is accomplished by a temporary clamping fixture until the start of the fusion bonding heat cycle. A complete, void-free fusion bond of seamless, full-strength quality is obtained through the plates; because the glass is heated well into its softening point and because of a large, distributed force that is developed that presses the two plates together from the difference in pressure between the furnace ambient (high pressure) and the channeling and microstructures in the plates (low pressure) due to the vacuum drawn. The apparatus and method may be used to fabricate microcapillary arrays for chemical electrophoresis; for example, any apparatus using a network of microfluidic channels embedded between plates of glass or similar moderate melting point substrates with a gradual softening point curve, or for assembly of glass-based substrates onto larger substrates, such as in flat panel display systems.

  11. Spiral Plate Method for Bacterial Determination

    PubMed Central

    Gilchrist, J. E.; Campbell, J. E.; Donnelly, C. B.; Peeler, J. T.; Delaney, J. M.

    1973-01-01

    A method is described for determining the number of bacteria in a solution by the use of a machine which deposits a known volume of sample on a rotating agar plate in an ever decreasing amount in the form of an Archimedes spiral. After the sample is incubated, different colony densities are apparent on the surface of the plate. A modified counting grid is described which relates area of the plate of volume of sample. By counting an appropriate area of the plate, the number of bacteria in the sample is estimated. This method was compared to the pour plate procedure with the use of pure and mixed cultures in water and milk. The results did not demonstrate a significant difference in variance between duplicates at the α = 0.01 level when concentrations of 600 to 12 × 105 bacteria per ml were used, but the spiral plate method gave counts that were higher than counts obtained by the pour plate method. The time and materials required for this method are substantially less than those required for the conventional aerobic pour plate procedure. Images PMID:4632851

  12. Pressure-Letdown Plates for Coal Gasifiers

    NASA Technical Reports Server (NTRS)

    Collins, E. R., Jr.

    1985-01-01

    Variation of pseudoporous plates used with coal gasifiers in pressure letdown stage of processing minimize clogging. Rotating plates containing variable gap annuli continually change flow path to enable erosionless reduction of gas pressure. Particles that otherwise clog porous plugs pass through gaps.

  13. Computing relative plate velocities: a primer

    SciTech Connect

    Bevis, M.

    1987-08-01

    Standard models of present-day plate motions are framed in terms of rates and poles of rotation, in accordance with the well-known theorem due to Euler. This article shows how computation of relative plate velocities from such models can be viewed as a simple problem in spherical trigonometry. A FORTRAN subroutine is provided to perform the necessary computations.

  14. Plate Tectonic Cycle. K-6 Science Curriculum.

    ERIC Educational Resources Information Center

    Blueford, J. R.; And Others

    Plate Tectonics Cycle is one of the units of a K-6 unified science curriculum program. The unit consists of four organizing sub-themes: (1) volcanoes (covering formation, distribution, and major volcanic groups); (2) earthquakes (with investigations on wave movements, seismograms and sub-suface earth currents); (3) plate tectonics (providing maps…

  15. 49 CFR 236.779 - Plate, top.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Plate, top. 236.779 Section 236.779 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF... OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.779 Plate, top....

  16. 49 CFR 236.779 - Plate, top.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Plate, top. 236.779 Section 236.779 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF... OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.779 Plate, top....

  17. 49 CFR 236.779 - Plate, top.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Plate, top. 236.779 Section 236.779 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF... OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.779 Plate, top....

  18. 49 CFR 236.779 - Plate, top.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Plate, top. 236.779 Section 236.779 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF... OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.779 Plate, top....

  19. 49 CFR 236.779 - Plate, top.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Plate, top. 236.779 Section 236.779 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF... OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.779 Plate, top....

  20. Improved nickel plating of Inconel X-750

    NASA Technical Reports Server (NTRS)

    Farmer, M. E.; Feeney, J. E.; Kuster, C. A.

    1969-01-01

    Electroplating technique with acid pickling provides a method of applying nickel plating on Inconel X-750 tubing to serve as a wetting agent during brazing. Low-stress nickel-plating bath contains no organic wetting agents that cause the nickel to blister at high temperatures.

  1. 30 CFR 22.10 - Approval plate.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... MINING PRODUCTS PORTABLE METHANE DETECTORS § 22.10 Approval plate. (a) Attachment to be made by manufacturers. (1) Manufacturers shall attach, stamp, or mold an approval plate on each permissible methane... follows: Permissible Methane Detector (or Permissible Methane Indicating Detector) Approval No. ___...

  2. Layered Plating Specimens For Mechanical Tests

    NASA Technical Reports Server (NTRS)

    Thompson, Linda B.; Flowers, Cecil E.

    1991-01-01

    Layered specimens readily made in standard sizes for tensile and other tests of mechanical properties. Standard specimen of metal ordinarily difficult to plate to standard grip thickness or diameter made by augmentation with easier-to-plate material followed by machining to standard size and shape.

  3. 49 CFR 213.123 - Tie plates.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Tie plates. 213.123 Section 213.123 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION TRACK SAFETY STANDARDS Track Structure § 213.123 Tie plates. (a) In Classes 3 through 5...

  4. 49 CFR 213.123 - Tie plates.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Tie plates. 213.123 Section 213.123 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION TRACK SAFETY STANDARDS Track Structure § 213.123 Tie plates. (a) In Classes 3 through 5...

  5. 49 CFR 213.123 - Tie plates.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Tie plates. 213.123 Section 213.123 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION TRACK SAFETY STANDARDS Track Structure § 213.123 Tie plates. (a) In Classes 3 through 5...

  6. 49 CFR 213.123 - Tie plates.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Tie plates. 213.123 Section 213.123 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION TRACK SAFETY STANDARDS Track Structure § 213.123 Tie plates. (a) In Classes 3 through 5...

  7. Cycloid kinematics of relative plate motion

    SciTech Connect

    Cronin, V.S.

    1987-11-01

    The trajectory of a point on one plate as observed from another plate is generally a complex curve and not a small circle around a single axis of relative motion, as is commonly assumed. The shape of the relative-motion path is given the general name spherical cycloid because of its morphological similarity to cycloid planetary trajectories described by early astronomers. The cycloid relative-motion model predicts that the following phenomena occur during finite displacements: (1) the relative velocity and the curvature of the trajectory of a point on one plate relative to another plate varies systematically; (2) plates wobble relative to one another; and (3) the angle of convergence and/or divergence varies systematically along the length of any given transform fault. The small-circle relative-motion model, whereby transform faults have been considered lines of pure slip along which crust is conserved, is not generally valid for finite relative displacements.

  8. Shock wave absorber having apertured plate

    DOEpatents

    Shin, Yong W.; Wiedermann, Arne H.; Ockert, Carl E.

    1985-01-01

    The shock or energy absorber disclosed herein utilizes an apertured plate maintained under the normal level of liquid flowing in a piping system and disposed between the normal liquid flow path and a cavity pressurized with a compressible gas. The degree of openness (or porosity) of the plate is between 0.01 and 0.60. The energy level of a shock wave travelling down the piping system thus is dissipated by some of the liquid being jetted through the apertured plate toward the cavity. The cavity is large compared to the quantity of liquid jetted through the apertured plate, so there is little change in its volume. The porosity of the apertured plate influences the percentage of energy absorbed.

  9. Shock wave absorber having apertured plate

    DOEpatents

    Shin, Y.W.; Wiedermann, A.H.; Ockert, C.E.

    1983-08-26

    The shock or energy absorber disclosed herein utilizes an apertured plate maintained under the normal level of liquid flowing in a piping system and disposed between the normal liquid flow path and a cavity pressurized with a compressible gas. The degree of openness (or porosity) of the plate is between 0.01 and 0.60. The energy level of a shock wave travelling down the piping system thus is dissipated by some of the liquid being jetted through the apertured plate toward the cavity. The cavity is large compared to the quantity of liquid jetted through the apertured plate, so there is little change in its volume. The porosity of the apertured plate influences the percentage of energy absorbed.

  10. Torsion and transverse bending of cantilever plates

    NASA Technical Reports Server (NTRS)

    Reissner, Eric; Stein, Manuel

    1951-01-01

    The problem of combined bending and torsion of cantilever plates of variable thickness, such as might be considered for solid thin high-speed airplane or missile wings, is considered in this paper. The deflections of the plate are assumed to vary linearly across the chord; minimization of the potential energy by means of the calculus of variations then leads to two ordinary linear differential equations for the bending deflections and the twist of the plate. Because the cantilever is analyzed as a plate rather than as a beam, the effect of constraint against axial warping in torsion is inherently included. The application of this method to specific problems involving static deflection, vibration, and buckling of cantilever plates is presented. In the static-deflection problems, taper and sweep are considered.

  11. Optimum design of geodesically stiffened composite plates

    NASA Technical Reports Server (NTRS)

    Guerdal, Zafer; Phillips, John L.

    1988-01-01

    With the goal of tailorability in mind, the in-plane stiffness characteristics of a particular grid stiffened plate configuration under axial and shear loads have been studied. The contribution of the skin to the stiffener network and the resultant skin/rib interaction is analyzed. For the given plate geometry and loads, it is shown that an optimum configuration does exist. To achieve optimally designed practical plate configurations, buckling constraints need to be included in the design. Due to the complex geometry and loading of the plates, a simplified local buckling analysis of isolated stiffeners and triangular skin elements between the stiffeners is considered. Development of a stiffener buckling analysis represent stiffeners as shear deformable plate elements is presented.

  12. Is There Really A North American Plate?

    NASA Astrophysics Data System (ADS)

    Krill, A.

    2011-12-01

    Lithospheric plates are typically identified from earthquake epicenters and evidence such as GPS movements. But no evidence indicates a plate boundary between the North American and South American Plates. Some plate maps show them separated by a transform boundary, but it is only a fracture zone. Other maps show an "undefined plate boundary" or put no boundary between these two plates (check Google images). Early plate maps showed a single large American Plate, quite narrow east of the Caribbean Plate (Le Pichon 1968, Morgan 1968). The North and South American Plates became established by the leading textbook Earth (Press & Siever 1974). On their map, from a Scientific American article by John Dewey (1972), these new plates were separated by an "uncertain plate boundary." The reasons for postulating a North American Plate were probably more psychological than geological. Each of the other continents of the world had its own plate, and North American geologists naturally wanted theirs. Similarly, European geographers used to view Europe as its own continent. A single large plate should again be hypothesized. But the term American Plate would now be ambiguous ("Which plate, North or South?") Perhaps future textbook authors could call it the "Two-American Plate." Textbook authors ultimately decide such global-tectonic matters. I became aware of textbook authors' opinions and influence from my research into the history of Alfred Wegener's continental drift (see Fixists vs. Mobilists by Krill 2011). Leading textbook author Charles Schuchert realized that continental drift would abolish his cherished paleogeographic models of large east-west continents (Eria, Gondwana) and small oceans (Poseiden, Nereis). He and his junior coauthors conspired to keep drift evidence out of their textbooks, from the 1934-editions until the 1969-editions (Physical Geology by Longwell et al. 1969, Historical Geology by Dunbar & Waage 1969). Their textbooks ruled in America. Textbooks

  13. Holographic NDT of thin titanium plate described

    NASA Astrophysics Data System (ADS)

    Yang, R.

    1986-01-01

    Holography is a technique for recording the amplitude and phase changes of an object on a photographic plate in the form of interference fringes. Because the holographic interference method can examine a component in the noncontact mode and is not bothered by complicated part shape or surface roughness, it has been widely used in nondestructive testing. In the rapidly developing aerospace industry, titanium and titanium alloy thin plates are used more and more but local delamination has been found in the production process of bonded titanium plates. Using ultrasonic methods, such defects are difficult to detect and large area delaminations with tightly closed edges can easily be missed. Other testing methods are also unsuccessful. A holographic method was developed for detecting defects in thin titanium plates and several high temperature alloy plates were tested. The testing equipment, methods and results are discussed.

  14. Volcanism in response to plate flexure.

    PubMed

    Hirano, Naoto; Takahashi, Eiichi; Yamamoto, Junji; Abe, Natsue; Ingle, Stephanie P; Kaneoka, Ichiro; Hirata, Takafumi; Kimura, Jun-Ichi; Ishii, Teruaki; Ogawa, Yujiro; Machida, Shiki; Suyehiro, Kiyoshi

    2006-09-01

    Volcanism on Earth is known to occur in three tectonic settings: divergent plate boundaries (such as mid-ocean ridges), convergent plate boundaries (such as island arcs), and hot spots. We report volcanism on the 135 million-year-old Pacific Plate not belonging to any of these categories. Small alkalic volcanoes form from small percent melts and originate in the asthenosphere, as implied by their trace element geochemistry and noble gas isotopic compositions. We propose that these small volcanoes erupt along lithospheric fractures in response to plate flexure during subduction. Minor extents of asthenospheric melting and the volcanoes' tectonic alignment and age progression in the direction opposite to that of plate motion provide evidence for the presence of a small percent melt in the asthenosphere. PMID:16873612

  15. Tectonic Evolution of the Jurassic Pacific Plate

    NASA Astrophysics Data System (ADS)

    Nakanishi, M.; Ishihara, T.

    2015-12-01

    We present the tectonic evolution of the Jurassic Pacific plate based on magnetic anomly lineations and abyssal hills. The Pacific plate is the largest oceanic plate on Earth. It was born as a microplate aroud the Izanagi-Farallon-Phoenix triple junction about 192 Ma, Early Jurassic [Nakanishi et al., 1992]. The size of the Pacific plate at 190 Ma was nearly half that of the present Easter or Juan Fernandez microplates in the East Pacific Rise [Martinez et at, 1991; Larson et al., 1992]. The plate boundary surrounding the Pacific plate from Early Jurassic to Early Cretaceous involved the four triple junctions among Pacific, Izanagi, Farallon, and Phoenix plates. The major tectonic events as the formation of oceanic plateaus and microplates during the period occurred in the vicinity of the triple junctions [e.g., Nakanishi and Winterer, 1998; Nakanishi et al., 1999], implying that the study of the triple junctions is indispensable for understanding the tectonic evolution of the Pacific plate. Previous studies indicate instability of the configuration of the triple junctions from Late Jurassic to Early Cretaceous (155-125 Ma). On the other hand, the age of the birth of the Pacific plate was determined assuming that all triple junctions had kept their configurations for about 30 m.y. [Nakanishi et al., 1992] because of insufficient information of the tectonic history of the Pacific plate before Late Jurassic.Increase in the bathymetric and geomagnetic data over the past two decades enables us to reveal the tectonic evolution of the Pacific-Izanagi-Farallon triple junction before Late Jurassic. Our detailed identication of magnetic anomaly lineations exposes magnetic bights before anomaly M25. We found the curved abyssal hills originated near the triple junction, which trend is parallel to magnetic anomaly lineations. These results imply that the configuration of the Pacific-Izanagi-Farallon triple junction had been RRR before Late Jurassic.

  16. Parallel Plate System for Collecting Data Used to Determine Viscosity

    NASA Technical Reports Server (NTRS)

    Kaukler, William (Inventor); Ethridge, Edwin C. (Inventor)

    2013-01-01

    A parallel-plate system collects data used to determine viscosity. A first plate is coupled to a translator so that the first plate can be moved along a first direction. A second plate has a pendulum device coupled thereto such that the second plate is suspended above and parallel to the first plate. The pendulum device constrains movement of the second plate to a second direction that is aligned with the first direction and is substantially parallel thereto. A force measuring device is coupled to the second plate for measuring force along the second direction caused by movement of the second plate.

  17. Spirit's Tracks around 'Home Plate'

    NASA Technical Reports Server (NTRS)

    2006-01-01

    [figure removed for brevity, see original site] Annotated Version

    This portion of an image acquired by the Mars Reconnaissance Orbiter's High Resolution Imaging Science Experiment camera shows the Spirit rover's winter campaign site. The rover is visible. So is the 'Low Ridge' feature where Spirit was parked with an 11-degree northerly tilt to maximize sunlight on the solar panels during the southern winter season. Tracks made by Spirit on the way to 'Home Plate' and to and from 'Tyrone,' an area of light-toned soils exposed by rover wheel motions, are also evident. The original image is catalogued as PSP_001513_1655_red and was taken Sept. 29, 2006.

    NASA's Jet Propulsion Laboratory, a division of the California Institute of Technology in Pasadena, manages the Mars Reconnaissance Orbiter for NASA's Science Mission Directorate, Washington. Lockheed Martin Space Systems, Denver, is the prime contractor for the project and built the spacecraft. The High Resolution Imaging Science Experiment is operated by the University of Arizona, Tucson, and the instrument was built by Ball Aerospace and Technology Corp., Boulder, Colo.

  18. The jubilee of plate tectonics

    NASA Astrophysics Data System (ADS)

    Glen, William; Frankel, Henry

    What should one expect at a birthday gathering for an idea that suffered disdain from birth, but was later transformed overnight into the ruling global theory of the Earth sciences? Tom Hilde and Richard Carlson (Texas A&M University, College Station, Tex.), under the auspices of the Texas A&M Geodynamics Research Institute, with the cooperation of the National Aeronautics and Space Administration (NASA) , the Inter-Union Commission on the Lithosphere, and the U.S. Geodynamics Committee, convened an unprecedented gathering of the makers of Earth science's modern revolution and a large number of their foremost disciples at Texas A&M April 22- 24 , 1987.Those who missed the show will have to read for weeks to learn of the panoply of profound new developments across the broad front of research bearing on plate tectonics, but those with an interest in their own intellectual genealogy will not be able to recapture the sense of historic moment that pervaded Rudder Tower Conference Center as many of the old revolutionaries opened windows on the past. Of the 20 key participants or originators who were invited to speak, all but four sent abstracts. Pleased and surprised by this strong response, the convenors found themselves in the rather difficult position of having to limit the number of talks by nonoriginators to 20. The unique assembly also provided the first opportunity to video interviews with more than a dozen of the originators.

  19. Lee plate equations for electroded quartz crystal plates with the consideration of electrode density and stiffness.

    PubMed

    Wang, Ji; Chen, Guojun; Du, Jianke

    2008-02-01

    Lee plate equations for high-frequency vibrations of piezoelectric plates have been established and improved over the last decades with the sole objective of obtaining the accurate prediction of frequency and mode shapes to aid crystal resonator design. The latest improvement includes extra terms related to derivatives of the flexural displacement to adjust the accuracy and consider electrodes for practical applications. As part of the efforts to make the equations applicable for resonator design with the improved frequency accuracy and consideration of electrodes, we derived Lee plate equations for electroded plates by changing the integration limits in the dimension reduction procedure to signify the dominant role of the crystal plate. By modifying the density terms in plate equations to include the contribution of both electrode stiffness and density, the accuracy of the thickness-shear vibration frequency of electroded plates is improved for commonly used electrode materials. PMID:18334357

  20. Reducing chromium losses from a chromium plating bath. 1987 summer intern report. Project conducted at New Dimension Plating, Hutchinson, Minnesota

    SciTech Connect

    Achman, D.

    1987-12-31

    The company employs about forty people and operates for one or two eight hour shifts with an average of 315 racks of chrome plating per eight hour day. They plate a variety of metals including copper, nickel, gold, brass and chromium. Chromium is the major metal plated and is usually the last step in plating cycle. Most parts are copper plated and then nickel plated in preparation for chrome plating. The main difference between New Dimension Plating and other plating shops is the variety of parts plated. As New Dimension Plating is a job shop, a wide range of parts such as motorcycle accessories, stove parts, and custom items are metal finished. The plating lines are manual, meaning employees dip the racks into the tanks by hand. This fact along with the fact that parts vary greatly in size and shape accounts for the significant drag-out on the chromium plating line.

  1. Shells on a Sphere: Tectonic Plate Motion and Plate Boundary Deformation

    NASA Astrophysics Data System (ADS)

    Apel, Edwin Victor, III

    Plate motion models have matured from being based only on geology and seismicity to incorporating space-based geodetic methods like GPS. I use a block modeling approach to incorporate both rigid block rotation and near-boundary elastic strain accumulation effects in a formal inversion of GPS velocities. Independent Okhotsk and Amurian microplate motions are tested using GPS velocities that constrain the plate kinematics of northeast Asia. Modeling favors scenarios with independent OKH and AMU motion, based on the application of F-test statistics. The plate-motion parameters of the independent plates are consistent with the kinematics inferred from earthquake focal mechanism solutions along their boundaries. GPS-measured velocities (15 from continuously recording stations within the stable India plate interior) geodetically constrain India plate motion, intraplate strain, and plate boundary deformation around the India plate. Dense station coverage from previously published studies allows rigorous testing of boundary parameterizations. I develop robust India plate motion parameters and see good agreement between predicted plate directions from the preferred model and the seismological data. Available GPS data in and around the Aegean region is combined and used to evaluate plate motion models, elastic plate boundary deformation and its relationship to seismogenic coupling along the Hellenic subduction zone. The A.D. 365 M ˜8.4, the A.D. 1303 M˜8 Crete suggest that portions of the plate interface must be locked. The primary focus of this study is to examine potential upper plate deformation resulting from a locked subduction interface, active hanging-wall extension, or both. I consider multiple model scenarios in an attempt to interpret the both the horizontal and vertical geodetic signals in the region and its implications for earthquake hazard assessment.

  2. Colorimetric microtiter plate receptor-binding assay for the detection of freshwater and marine neurotoxins targeting the nicotinic acetylcholine receptors

    USGS Publications Warehouse

    Rubio, Fernando; Kamp, Lisa; Carpino, Justin; Faltin, Erin; Loftin, Keith A.; Molgó, Jordi; Aráoz, Rómulo

    2014-01-01

    Anatoxin-a and homoanatoxin-a, produced by cyanobacteria, are agonists of nicotinic acetylcholine receptors (nAChRs). Pinnatoxins, spirolides, and gymnodimines, produced by dinoflagellates, are antagonists of nAChRs. In this study we describe the development and validation of a competitive colorimetric, high throughput functional assay based on the mechanism of action of freshwater and marine toxins against nAChRs. Torpedo electrocyte membranes (rich in muscle-type nAChR) were immobilized and stabilized on the surface of 96-well microtiter plates. Biotinylated α-bungarotoxin (the tracer) and streptavidin-horseradish peroxidase (the detector) enabled the detection and quantitation of anatoxin-a in surface waters and cyclic imine toxins in shellfish extracts that were obtained from different locations across the US. The method compares favorably to LC/MS/MS and provides accurate results for anatoxin-a and cyclic imine toxins monitoring. Study of common constituents at the concentrations normally found in drinking and environmental waters, as well as the tolerance to pH, salt, solvents, organic and inorganic compounds did not significantly affect toxin detection. The assay allowed the simultaneous analysis of up to 25 samples within 3.5 h and it is well suited for on-site or laboratory monitoring of low levels of toxins in drinking, surface, and ground water as well as in shellfish extracts.

  3. Design of a titering assay for lentiviral vectors utilizing direct extraction of DNA from transduced cells in microtiter plates

    PubMed Central

    Murphy, Michele E; Vin, Chintan D; Slough, Megan M; Gombotz, Wayne R; Kelley-Clarke, Brenna

    2016-01-01

    Using lentiviral vector products in clinical applications requires an accurate method for measuring transduction titer. For vectors lacking a marker gene, quantitative polymerase chain reaction is used to evaluate the number of vector DNA copies in transduced target cells, from which a transduction titer is calculated. Immune Design previously described an integration-deficient lentiviral vector pseudotyped with a modified Sindbis virus envelope for use in cancer immunotherapy (VP02, of the ZVex platform). Standard protocols for titering integration-competent lentiviral vectors employ commercial spin columns to purify vector DNA from transduced cells, but such columns are not optimized for isolation of extrachromosomal (nonintegrated) DNA. Here, we describe a 96-well transduction titer assay in which DNA extraction is performed in situ in the transduction plate, yielding quantitative recovery of extrachromosomal DNA. Vector titers measured by this method were higher than when commercial spin columns were used for DNA isolation. Evaluation of the method’s specificity, linear range, and precision demonstrate that it is suitable for use as a lot release assay to support clinical trials with VP02. Finally, the method is compatible with titering both integrating and nonintegrating lentiviral vectors, suggesting that it may be used to evaluate the transduction titer for any lentiviral vector. PMID:26942209

  4. Colorimetric microtiter plate receptor-binding assay for the detection of freshwater and marine neurotoxins targeting the nicotinic acetylcholine receptors.

    PubMed

    Rubio, Fernando; Kamp, Lisa; Carpino, Justin; Faltin, Erin; Loftin, Keith; Molgó, Jordi; Aráoz, Rómulo

    2014-12-01

    Anatoxin-a and homoanatoxin-a, produced by cyanobacteria, are agonists of nicotinic acetylcholine receptors (nAChRs). Pinnatoxins, spirolides, and gymnodimines, produced by dinoflagellates, are antagonists of nAChRs. In this study we describe the development and validation of a competitive colorimetric, high throughput functional assay based on the mechanism of action of freshwater and marine toxins against nAChRs. Torpedo electrocyte membranes (rich in muscle-type nAChR) were immobilized and stabilized on the surface of 96-well microtiter plates. Biotinylated α-bungarotoxin (the tracer) and streptavidin-horseradish peroxidase (the detector) enabled the detection and quantitation of anatoxin-a in surface waters and cyclic imine toxins in shellfish extracts that were obtained from different locations across the US. The method compares favorably to LC/MS/MS and provides accurate results for anatoxin-a and cyclic imine toxins monitoring. Study of common constituents at the concentrations normally found in drinking and environmental waters, as well as the tolerance to pH, salt, solvents, organic and inorganic compounds did not significantly affect toxin detection. The assay allowed the simultaneous analysis of up to 25 samples within 3.5 h and it is well suited for on-site or laboratory monitoring of low levels of toxins in drinking, surface, and ground water as well as in shellfish extracts. PMID:25260255

  5. Scaling of energy absorbing composite plates

    NASA Technical Reports Server (NTRS)

    Jackson, Karen; Lavoie, J. Andre; Morton, John

    1994-01-01

    The energy absorption response and crushing characteristics of geometrically scaled graphite-Kevlar epoxy composite plates were investigated. Two different trigger mechanisms including notch, and steeple geometries were incorporated into the plate specimens to initiate crushing. Sustained crushing was achieved with a new test fixture which provided lateral support to prevent global buckling. Values of specific sustained crushing stress (SSCS) were obtained which were lower than values reported for tube specimens from previously published data. Two sizes of hybrid plates were fabricated; a baseline or model plate, and a full-scale plate with inplane dimensions scaled by a factor of two. The thickness dimension of the full-scale plates was increased using two different techniques: the ply-level method in which each ply orientation in the baseline laminate stacking sequence is doubled, and the sublaminate technique in which the baseline laminate stacking sequence is repeated as a group. Results indicated that the SSCS has a small dependence on trigger mechanism geometry. However, a reduction in the SSCS of 10-25% was observed for the full-scale plates as compared with the baseline specimens, indicating a scaling effect in the crushing response.

  6. Scaling of energy absorbing composite plates

    NASA Technical Reports Server (NTRS)

    Jackson, Karen; Morton, John; Traffanstedt, Catherine; Boitnott, Richard

    1992-01-01

    The energy absorption response and crushing characteristics of geometrically scaled graphite-Kevlar epoxy composite plates were investigated. Three different trigger mechanisms including chamfer, notch, and steeple geometries were incorporated into the plate specimens to initiate crushing. Sustained crushing was achieved with a simple test fixture which provided lateral support to prevent global buckling. Values of specific sustained crushing stress (SSCS) were obtained which were comparable to values reported for tube specimens from previously published data. Two sizes of hybrid plates were fabricated; a baseline or model plate, and a full-scale plate with in-plane dimensions scaled by a factor of two. The thickness dimension of the full-scale plates was increased using two different techniques; the ply-level method in which each ply orientation in the baseline laminate stacking sequence is doubled, and the sublaminate technique in which the baseline laminate stacking sequence is repeated as a group. Results indicated that the SSCS is independent of trigger mechanism geometry. However, a reduction in the SSCS of 10-25 percent was observed for the full-scale plates as compared with the baseline specimens, indicating a scaling effect in the crushing response.

  7. Determination of glucose using a coupled-enzymatic reaction with new fluoride selective optical sensing polymeric film coated in microtiter plate wells

    PubMed Central

    Abd-Rabboh, Hisham S. M.; Meyerhoff, Mark E.

    2007-01-01

    The determination of glucose in beverages is demonstrated using newly developed fluoride selective optical sensing polymeric film that contains aluminum (III) octaethylporphyrin (Al[OEP]) ionophore and the chromoionophore ETH7075 cast at the bottom of wells of a 96-well polypropylene microtiter plate. The method uses a dual enzymatic reaction involving glucose oxidase enzyme (GOD) and horseradish peroxidase (HRP), along with an organofluoro-substrate (4-fluorophenol) as the source of fluoride ions. The concentration of fluoride ions after enzymatic reaction is directly proportional to the glucose level in the sample. The method has a detection limit of 0.8 mmol L−1, a linear range of 0.9– 40 mmol L−1 and a sensitivity of 0.125 absorbance unit/decade of glucose concentration. Glucose levels in several beverage samples determined using the proposed method correlate well with a reference spectrophotometric enzyme method based on detection of hydrogen peroxide using bromopyrogallol red dye (BPR). The new method can also be used to determine H2O2 concentrations in the 0.1 - 50 mmol L−1 range using a single enzymatic reaction involving H2O2 oxidation of 4-fluorophenol catalyzed by HRP. The methodology could potentially be used to detect a wide range of substrates for which selective oxidase enzymes exist (to generate H2O2), with the high throughput of simple microtiter plate detection scheme. PMID:18480896

  8. Electrochemical Machining of Metal Plates

    SciTech Connect

    Cooper, J F; Evans, M C

    2005-03-04

    Electrochemical machining (ECM) with concentrated sodium chlorate electrolyte was used to rapidly cut a circular groove (13 cm diameter, 0.2 cm wide) through a 0.15 cm thick sheet of steel--thus opening a 5-inch porthole in as little as 10 minutes. The most favorable operating conditions were: T = 22 C; chlorate concentration 600 g NaClO{sub 3}/liter-solution; electric power of 100 A at 10 V; and flow of 0.5 l/s at a pressure drop of 10 kPa (1.5 psi). The porthole may be removed entirely by electrochemical means, or the electrochemical dissolution may continue until only thin membrane remains that is subsequently cut with a utility knife. An array of thermocouples was used to track temperature in the flowing solution and in the trough being machined; the maximum increase in temperature in the trough was 5 C over that of the flowing electrolyte which increased in temperature by 19 C because of power dissipation. ECM is shown feasible for rapid perforation of plates of ferrous and non-ferrous metals using portable equipment and commercial batteries. The technique can be extended to cut perforations of arbitrary shape through non-planar surfaces using a deformable ring cathode. Analysis of the power requirements for electrolyte flow and ECM indicate a total system weight of less than 45 kg (100 lb) using a commercial NiMH battery. The technique is recommended for reduction to practice and demonstration on full scale as an engineering prototype.

  9. Modeling Residual Stresses in Ceramic Plates

    SciTech Connect

    Cantavella, V.; Moreno, A.; Mezquita, A.; Reig, Y.

    2008-02-15

    The generation of residual stresses during cooling of layered ceramic plates has been modeled. Each plate comprises a body and two thin layers (engobe and glaze). The model takes into account two types of stresses: thermal stresses, resulting from temperature gradients inside the plate during cooling, and the stresses produced by the mismatch of the coefficient of thermal expansion (CTE) of the layers. The body has been simulated using a linear viscoelastic constitutive equation. The engobe and the glaze layer have been considered as elastic solids below a certain temperature (setting temperature: T{sub a}). Above T{sub a} these two layers have no mechanical influence on the body.

  10. Bi-coolant flat plate solar collector

    NASA Astrophysics Data System (ADS)

    Chon, W. Y.; Green, L. L.

    The feasibility study of a flat plate solar collector which heats air and water concurrently or separately was carried out. Air flows above the collector absorber plate, while water flows in tubes soldered or brazed beneath the plate. The collector efficiencies computed for the flow of both air and water are compared with those for the flow of a single coolant. The results show that the bi-coolant collector efficiency computed for the entire year in Buffalo, New York is higher than the single-coolant collector efficiency, although the efficiency of the water collector is higher during the warmer months.

  11. Ion plating with an induction heating source

    NASA Technical Reports Server (NTRS)

    Spalvins, T.; Brainard, W. A.

    1976-01-01

    Induction heating is introduced as an evaporation heat source in ion plating. A bare induction coil without shielding can be directly used in the glow discharge region with no arcing. The only requirement is to utilize an rf inductive generator with low operating frequency of 75 kHz. Mechanical simplicity of the ion plating apparatus and ease of operation is a great asset for industrial applications; practically any metal such as nickel, iron, and the high temperature refractories can be evaporated and ion plated.

  12. Seismic anisotropy above a subducting plate

    SciTech Connect

    Shih, X.R.; Meyer, R.P. ); Schneider, J.F. )

    1991-08-01

    Shear-wave splitting observed in northeastern Colombia has provided evidence of seismic anisotropy in a shear zone immediately above a subducting plate. In an upper mantle composed mainly of olivine (57%) and orthopyroxene (17%), the splitting can be interpreted by wave propagation in an anisotropic medium of orthorhombic symmetry that results from alignment of these intrinsically anisotropic minerals. The mechanism of alignment is most likely the shearing associated with the subduction, aided by fluids migrating from the subducting plate when the plate exceeds 100 km in depth.

  13. Strongly coupled stress waves in heterogeneous plates.

    NASA Technical Reports Server (NTRS)

    Wang, A. S. D.; Chou, P. C.; Rose, J. L.

    1972-01-01

    Consideration of coupled stress waves generated by an impulsive load applied at one end of a semiinfinite plate. For the field equations governing the one-dimensional coupled waves a hyperbolic system of equations is obtained in which a strong coupling in the second derivatives exists. The method of characteristics described by Chou and Mortimer (1967) is extended to cover the case of strong coupling, and a study is made of the transient stress waves in a semiinfinite plate subjected to an initial step input. Coupled discontinuity fronts are found to propagate at different velocities. The normal plate stress and the bending moment at different time regimes are illustrated by graphs.

  14. Rough Fresnel zone plates over metallic surfaces.

    PubMed

    Salgado-Remacha, Francisco Javier; Sanchez-Brea, Luis Miguel; Alvarez-Rios, Francisco Javier; Bernabeu, Eusebio

    2010-04-01

    We analyze the focusing properties of Fresnel zone plates fabricated over steel tapes using laser ablation. Our intention is to implement the use of micro-optical elements when the use of conventional chrome-glass elements is not indicated. Because of the manufacture process, the surface presents a certain anisotropic roughness, which reduces the focusing properties. First, we develop numerical simulations by means of the Rayleigh-Sommerfeld approach, showing how roughness in both levels of the Fresnel zone plate affects the focalization of the lens. We also manufacture Fresnel zone plates over steel tape, and perform experimental verification that corroborates the numerical results. PMID:20357856

  15. Improvements in Cold-Plate Fabrication

    NASA Technical Reports Server (NTRS)

    Zaffetti, Mark A.; Taddey, Edmund P.; Laurin, Michael B.; Chabebe, Natalia

    2012-01-01

    Five improvements are reported in cold-plate fabrication. This cold plate is part of a thermal control system designed to serve on space missions. The first improvement is the merging of the end sheets of the cold plate with the face sheets of the structural honeycomb panel. The cold plate, which can be a brazed assembly, uses the honeycomb face sheet as its end sheet. Thus, when the honeycomb panel is fabricated, the face sheet that is used is already part of the cold plate. In addition to reducing weight, costs, and steps, the main benefit of this invention is that it creates a more structurally sound assembly. The second improvement involves incorporation of the header into the closure bar to pass the fluid to a lower layer. Conventional designs have used a separate header, which increases the geometry of the system. The improvement reduces the geometry, thus allowing the cold plate to fit into smaller area. The third improvement eliminates the need of hose, tube, or manifold to supply the cooling fluid externally. The external arrangement can be easily damaged and is vulnerable to leakage. The new arrangement incorporates an internal fluid transfer tube. This allows the fluid to pass from one cold plate to the other without any exposed external features. The fourth improvement eliminates separate fabrication of cold plate(s) and structural members followed by a process of attaching them to each other. Here, the structural member is made of material that can be brazed just as that of the cold plate. Now the structural member and the cold plate can be brazed at the same time, creating a monolithic unit, and thus a more structurally sound assembly. Finally, the fifth improvement is the elimination of an additional welding step that can damage the braze joints. A tube section, which is usually welded on after the braze process, is replaced with a more structurally sound configuration that can be brazed at the same time as the rest of the cold plate.

  16. Laminated anisotropic reinforced plastic plates and shells

    NASA Technical Reports Server (NTRS)

    Korolev, V. I.

    1981-01-01

    Basic technical theories and engineering calculation equations for anisotropic plates and shells made of rigid reinforced plastics, mainly laminated fiberglass, are presented and discussed. Solutions are given for many problems of design of structural plates and shells, including curved sections and tanks, as well as two chapters on selection of the optimum materials, are given. Accounting for interlayer shearing and transverse separation, which are new engineering properties, are discussed. Application of the results obtained to thin three ply plates and shells wth a light elastic filler is presented and discussed.

  17. Screen test for cadmium and nickel plates

    NASA Technical Reports Server (NTRS)

    Phan, Angie H.; Zimmerman, Albert H.

    1994-01-01

    A new procedure is described which was recently developed to quantify loading uniformity of nickel and cadmium plates and to screen finished electrodes prior to cell assembly. The technique utilizes the initial solubility rates of the active material in a standard chemical deloading solution at fixed conditions. The method can provide a reproducible indication of plate loading uniformity in situations where high surface loading limits the free flow of deloading solution into the internal porosity of the sinter plate. A preliminary study indicates that 'good' cell performance is associated with higher deloading rates.

  18. Fiber optic mounted laser driven flyer plates

    SciTech Connect

    Paisley, D.L.

    1990-12-31

    This invention is comprised of a laser driven flyer plate where the flyer plate is deposited directly onto the squared end of an optical fiber. The plasma generated by a laser pulse drives the flyer plate toward a target. In another embodiment, a first metal layer is deposited onto the squared end of an optical fiber, followed by a layer of a dielectric material and a second metal layer. The laser pulse generates a plasma in the first metal layer, but the plasma is kept away from the second metal layer by the dielectric layer until the pressure reaches the point where shearing occurs. 2 figs.

  19. Modeling Residual Stresses in Ceramic Plates

    NASA Astrophysics Data System (ADS)

    Cantavella, V.; Moreno, A.; Mezquita, A.; Reig, Y.

    2008-02-01

    The generation of residual stresses during cooling of layered ceramic plates has been modeled. Each plate comprises a body and two thin layers (engobe and glaze). The model takes into account two types of stresses: thermal stresses, resulting from temperature gradients inside the plate during cooling, and the stresses produced by the mismatch of the coefficient of thermal expansion (CTE) of the layers. The body has been simulated using a linear viscoelastic constitutive equation. The engobe and the glaze layer have been considered as elastic solids below a certain temperature (setting temperature: Ta). Above Ta these two layers have no mechanical influence on the body.

  20. Effusion plate using additive manufacturing methods

    DOEpatents

    Johnson, Thomas Edward; Keener, Christopher Paul; Ostebee, Heath Michael; Wegerif, Daniel Gerritt

    2016-04-12

    Additive manufacturing techniques may be utilized to construct effusion plates. Such additive manufacturing techniques may include defining a configuration for an effusion plate having one or more internal cooling channels. The manufacturing techniques may further include depositing a powder into a chamber, applying an energy source to the deposited powder, and consolidating the powder into a cross-sectional shape corresponding to the defined configuration. Such methods may be implemented to construct an effusion plate having one or more channels with a curved cross-sectional geometry.

  1. Viscoelastic flow between two infinite parallel porous plates, one plate oscillating and the other plate in uniform motion

    NASA Astrophysics Data System (ADS)

    Roy, J. S.; Nayak, P.

    1981-09-01

    An iteration procedure is used to solve fluid dynamics equations describing viscoelastic incompressible flow between two infinite parallel porous plates, one oscillating and the other in uniform motion. The solutions obtained are valid for small values of the elastic parameter S. The effects of the Reynolds number and the elastic parameter S on the velocity distribution and the shearing stress at the plates are analyzed.

  2. Electromagnetic semitransparent δ-function plate: Casimir interaction energy between parallel infinitesimally thin plates

    NASA Astrophysics Data System (ADS)

    Parashar, Prachi; Milton, Kimball A.; Shajesh, K. V.; Schaden, M.

    2012-10-01

    We derive boundary conditions for electromagnetic fields on a δ-function plate. The optical properties of such a plate are shown to necessarily be anisotropic in that they only depend on the transverse properties of the plate. We unambiguously obtain the boundary conditions for a perfectly conducting δ-function plate in the limit of infinite dielectric response. We show that a material does not “optically vanish” in the thin-plate limit. The thin-plate limit of a plasma slab of thickness d with plasma frequency ωp2=ζp/d reduces to a δ-function plate for frequencies (ω=iζ) satisfying ζd≪ζpd≪1. We show that the Casimir interaction energy between two parallel perfectly conducting δ-function plates is the same as that for parallel perfectly conducting slabs. Similarly, we show that the interaction energy between an atom and a perfect electrically conducting δ-function plate is the usual Casimir-Polder energy, which is verified by considering the thin-plate limit of dielectric slabs. The “thick” and “thin” boundary conditions considered by Bordag are found to be identical in the sense that they lead to the same electromagnetic fields.

  3. Thermo-mechanical buckling analysis of FGM plate using generalized plate theory

    NASA Astrophysics Data System (ADS)

    Sharma, Kanishk; Kumar, Dinesh; Gite, Anil

    2016-05-01

    This paper investigates the thermo-mechanical buckling behavior of simply-supported FGM plate under the framework of generalized plate theory (GPT), which includes classical plate theory (CPT), first order shear deformation theory (FSDT) and higher order shear deformation theory (HSDT) as special cases. The governing equations for FGM plate under thermal and mechanical loading conditions are derived from the principle of virtual displacements and Navier-type solution is assumed for simply supported boundary condition. The efficiency and applicability of presented methodology is illustrated by considering various examples of thermal and mechanical buckling of FGM plates. The closed form solutions in the form of critical thermal and mechanical buckling loads, predicted by CPT, FSDT and HSDT are compared for different side-to-thickness of FGM plate. Subsequently, the effect of material gradation profile on critical buckling parameters is examined by evaluating the buckling response for a range of power law indexes. The effect of geometrical parameters on mechanical buckling of FGM plate under uni-axial and bi-axial loading conditions are also illustrated by calculating the critical load for various values of slenderness ratios. Furthermore a comparative analysis of critical thermal buckling loads of FGM plate for different temperature profiles is also presented. It is identified that all plate theories predicted approximately same critical buckling loads and critical buckling temperatures for thin FGM plate, however for thick FGM plates, CPT overestimates the critical buckling parameters. Moreover the critical buckling loads and critical buckling temperatures of FGM plate are found to be significantly lower than the corresponding homogenous isotropic ceramic plate (n=0).

  4. Coloured Rings Produced on Transparent Plates

    ERIC Educational Resources Information Center

    Suhr, Wilfried; Schlichting, H. Joachim

    2007-01-01

    Beautiful colored interference rings can be produced by using transparent plates such as window glass. A simple model explains this effect, which was described by Newton but has almost been forgotten. (Contains 11 figures.)

  5. The Elasto-Plastic Stability of Plates

    NASA Technical Reports Server (NTRS)

    Ilyushin, A. A.

    1947-01-01

    This article explains results developed from the following research: 'The Stability of Plates and Shells beyond the Elastic Limit.' A significant improvement is found in the derivation of the relations between the stress factors and the strains resulting from the instability of plates and shells. In a strict analysis, the problem reduces to the solution of two simultaneous nonlinear partial differential equations of the fourth order in the deflection and stress function, and in the approximate analysis to a single linear equation of the Bryan type. Solutions are given for the special cases of a rectangular plate buckling into a cylindrical form, and of an arbitrarily shaped plate under uniform compression. These solutions indicate that the accuracy obtained by the approximate method is satisfactory.

  6. A New Spin: CDs as Printing Plates.

    ERIC Educational Resources Information Center

    Gamble, Harriet

    2000-01-01

    Describes a printmaking activity for use in tenth- to twelfth-grade art classes. Students use compact discs as printing plates, on which they depict a musical theme with drypoint etching. Discusses the process in detail. (CMK)

  7. Characterization of Tri-lab Tantalum Plate.

    SciTech Connect

    Buchheit, Thomas E.; Cerreta, Ellen K.; Deibler, Lisa Anne; Chen, Shu-Rong; Michael, Joseph R.

    2014-09-01

    This report provides a detailed characterization Tri-lab Tantalum (Ta) plate jointly purchased from HCStark Inc. by Sandia, Los Alamos and Lawrence Livermore National Laboratories. Data in this report was compiled from series of material and properties characterization experiments carried out at Sandia (SNL) and Los Alamos (LANL) Laboratories through a leveraged effort funded by the C2 campaign. Results include microstructure characterization detailing the crystallographic texture of the material and an increase in grain size near the end of the rolled plate. Mechanical properties evaluations include, compression cylinder, sub-scale tension specimen, micohardness and instrumented indentation testing. The plate was found to have vastly superior uniformity when compare with previously characterized wrought Ta material. Small but measurable variations in microstructure and properties were noted at the end, and at the top and bottom edges of the plate.

  8. Polar Plate Theory for Orthogonal Anisotropy

    NASA Technical Reports Server (NTRS)

    Bailey, Michelle D.; Bower, Mark V.

    2000-01-01

    Laminated fiber-reinforced (or filamentary) composites are used today for their high strength-to-weight and stiffness-to-weight ratios. However, because of the anisotropic behavior of composites, determining the response on a macroscopic scale is challenging. This is particularly evident in the evaluation of the governing differential equations of a circular disk with the fibers of the lamina oriented with rectilinear orthogonality. This includes any situation involving a composite plate of circular geometry in which out-of-plane displacements due to load are desired, such as fastener pull through loading of a composite plate. Current analysis techniques use numerical methods with rectilinear coordinate systems to solve problems with circular geometry. These analyses over predict plate stiffness by 20% and underpredict failure by 70%. Consequently, there is a need to transform classical composite plate theory to a polar coordinate system. In order to better analyze structures with circular geometries the classical composite plate equations are transformed into the plate equations for a rectilinearly anisotropic composite in polar coordinates. A composite plate is typically a laminate of fibers in rectilinear directions. Subsequent to the lay-tip the necessary geometry is cut out of a rectangular plate. In a similar manner, the derivation of the plate equation starts with the fundamental definitions of strain, displacement and curvature and incorporates the material property angular dependence into the equilibrium equations for a differential polar element. In the transformed state, the stiffness coefficients are no longer constant, adding to the complexity of the governing differential equations. This paper discusses the new derivation and evaluation of the plate equations for a circular composite disk with orthogonal rectilinear anisotropy. The resultant new three partial differential equations, which describe the circular anisotropic plate, can be used to

  9. Vibro-acoustic analysis of composite plates

    NASA Astrophysics Data System (ADS)

    Sarigül, A. S.; Karagözlü, E.

    2014-03-01

    Vibro-acoustic analysis plays a vital role on the design of aircrafts, spacecrafts, land vehicles and ships produced from thin plates backed by closed cavities, with regard to human health and living comfort. For this type of structures, it is required a coupled solution that takes into account structural-acoustic interaction which is crucial for sensitive solutions. In this study, coupled vibro-acoustic analyses of plates produced from composite materials have been performed by using finite element analysis software. The study has been carried out for E-glass/Epoxy, Kevlar/Epoxy and Carbon/Epoxy plates with different ply angles and numbers of ply. The effects of composite material, ply orientation and number of layer on coupled vibro-acoustic characteristics of plates have been analysed for various combinations. The analysis results have been statistically examined and assessed.

  10. The Continental Plates are Getting Thicker.

    ERIC Educational Resources Information Center

    Kerr, Richard A.

    1986-01-01

    Reviews seismological studies that provide evidence of the existence of continental roots beneath the continents. Suggests, that through the collisions of plate tectonics, continents stabilized part of the mobile mantle rock beneath them to form deep roots. (ML)

  11. Ultralight shape-recovering plate mechanical metamaterials

    NASA Astrophysics Data System (ADS)

    Davami, Keivan; Zhao, Lin; Lu, Eric; Cortes, John; Lin, Chen; Lilley, Drew E.; Purohit, Prashant K.; Bargatin, Igor

    2015-12-01

    Unusual mechanical properties of mechanical metamaterials are determined by their carefully designed and tightly controlled geometry at the macro- or nanoscale. We introduce a class of nanoscale mechanical metamaterials created by forming continuous corrugated plates out of ultrathin films. Using a periodic three-dimensional architecture characteristic of mechanical metamaterials, we fabricate free-standing plates up to 2 cm in size out of aluminium oxide films as thin as 25 nm. The plates are formed by atomic layer deposition of ultrathin alumina films on a lithographically patterned silicon wafer, followed by complete removal of the silicon substrate. Unlike unpatterned ultrathin films, which tend to warp or even roll up because of residual stress gradients, our plate metamaterials can be engineered to be extremely flat. They weigh as little as 0.1 g cm-2 and have the ability to `pop-back' to their original shape without damage even after undergoing multiple sharp bends of more than 90°.

  12. Plate measurements and reductions at Muenster

    NASA Astrophysics Data System (ADS)

    Teuber, D.; Tucholke, H. J.; Volkmer, C. C.; Budell, R.; Duemmler, R.; Horstmann, H.; Scheuer, H. G.; Seitter, W. C.

    1984-04-01

    A microdensitometer used with astronomical photography plates is described. Positional error derived from repeated measurements of a sharp edge is of the order of 0.1 microns with only small increases for scan speeds near the beginning and the end of the full scale from 0 to 226 mm/sec. Positional measurements of stars using Gauss fits to marginal distributions yield differences of 0.6 microns for different plate orientations. Differences with respect to catalog positions, using quadratic reduction models, yield a mean of 1.2 microns for well-exposed IIa-O plates with plate scales of 40 sec/mm and reference stars from the AGK3 corresponding to 0.05 sec for single measurements. Photometric accuracy for a typical multiplier voltage is 0.25% in density 3, 0.29% in transmission 1.

  13. Stop motion microphotography of laser driven plates

    SciTech Connect

    Frank, A.M.; Trott, W.M.

    1994-09-01

    Laser driven plates have been used for several years for high velocity shock wave and impact studies. Recent questions about the integrity and ablation rates of these plates coupled with an improved capability for microscopic stop motion photography led to this study. For these experiments, the plates were aluminum, coated on the ends of optical fibers. A high power laser pulse in the fiber ionizes the aluminum at the fiber/coating interface. The plasma thus created accelerates the remaining aluminum to high velocities, several kilometers per second. We defined {open_quotes}thick{close_quotes} or {open_quotes}thin{close_quotes} coatings as those where a flying plate (flyer) was launched vs. the material being completely ionized. Here we were specifically interested in the thick/thin boundary to develop data for the numerical models attempting to predict flyer behavior.

  14. 19 CFR 115.32 - Approval plates.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... clearly visible place on or near one of the doors or other main openings of each container manufactured to...). The following shall be embossed on or stamped into the surface of the approval plate: (a)...

  15. Anterior Cervical Discectomy and Fusion with Plating

    MedlinePlus Videos and Cool Tools

    Anterior Cervical Discectomy and Fusion with Plating Broward Health Medical Center Fort Lauderdale, FL November 17, 2011 I'm Dr. Matthew Moore, head of the Spine Care Center here at North Broward Medical Center. And ...

  16. White Light Photorefractive Phase Zone Plates

    NASA Astrophysics Data System (ADS)

    Gao, Yuan-Mei; Liu, Si-Min

    2008-02-01

    Incoherent white light from an incandescent source is employed to fabricate volume phase zone plates in LiNbO3: Fe, for the first time to our knowledge, which can guide and modulate the input white light or laser light. The diffractive efficiency of the white light volume phase zone plates fabricated can reach as high as 12%. In addition, we test the volume phase zone plates by a probe beam and find that the volume phase zone plate is present in the direction perpendicular to the c-axis and absent in the direction parallel to the c-axis. This directly proves the existence of photovoltaic photorefractive anisotropy of white light.

  17. Loading errors in cone-plate rheometry

    NASA Astrophysics Data System (ADS)

    Davies, A. J.

    2015-12-01

    Errors arising from the under- and overfilling of cone-plate geometries have been investigated for combinations of smooth and micro-roughened cone-plate geometries. We observed experimentally that 0.1 ml deviations in the loading volume, such as can occur due to subjective filling or evaporation, will proportionally change the measured viscosity by 2-3%. We also give a simple method to avoid these errors during routine measurements.

  18. Electrochemical cell and separator plate thereof

    DOEpatents

    Baker, Bernard S.; Dharia, Dilip J.

    1979-10-02

    A fuel cell includes a separator plate having first and second flow channels extending there through contiguously with an electrode and respectively in flow communication with the cell electrolyte and in flow isolation with respect to such electrolyte. In fuel cell system arrangement, the diverse type channels are supplied in common with process gas for thermal control purposes. The separator plate is readily formed by corrugation of integral sheet material. 10 figs.

  19. Electrochemical cell and separator plate thereof

    DOEpatents

    Baker, Bernard S.; Dharia, Dilip J.

    1979-01-01

    A fuel cell includes a separator plate having first and second flow channels extending therethrough contiguously with an electrode and respectively in flow communication with the cell electrolyte and in flow isolation with respect to such electrolyte. In fuel cell system arrangement, the diverse type channels are suplied in common with process gas for thermal control purposes. The separator plate is readily formed by corrugation of integral sheet material.

  20. Plate Tectonics in the Late Paleozoic

    NASA Astrophysics Data System (ADS)

    Domeier, Mat; Torsvik, Trond

    2014-05-01

    As the chronicle of plate motions through time, paleogeography is fundamental to our understanding of plate tectonics and its role in shaping the geology of the present-day. To properly appreciate the history of tectonics—and its influence on the deep Earth and climate—it is imperative to seek an accurate and global model of paleogeography. However, owing to the incessant loss of oceanic lithosphere through subduction, the paleogeographic reconstruction of 'full-plates' (including oceanic lithosphere) becomes increasingly challenging with age. Prior to 150 Ma ~60% of the lithosphere is missing and reconstructions are developed without explicit regard for oceanic lithosphere or plate tectonic principles; in effect, reflecting the earlier mobilistic paradigm of continental drift. Although these 'continental' reconstructions have been immensely useful, the next-generation of mantle models requires global plate kinematic descriptions with full-plate reconstructions. Moreover, in disregarding (or only loosely applying) plate tectonic rules, continental reconstructions fail to take advantage of a wealth of additional information in the form of practical constraints. Following a series of new developments, both in geodynamic theory and analytical tools, it is now feasible to construct full-plate models that lend themselves to testing by the wider Earth-science community. Such a model is presented here for the late Paleozoic (410-250 Ma). Although we expect this model to be particularly useful for numerical mantle modeling, we hope that it can also serve as a general framework for understanding late Paleozoic tectonics, one on which future improvements can be built and further tested.

  1. Method for plating with metal oxides

    DOEpatents

    Silver, G.L.; Martin, F.S.

    1994-08-23

    A method is disclosed of plating hydrous metal oxides on at least one substrate, which method is indifferent to the electrochemical properties of the substrate, and comprises reacting metallic ions in aqueous solution with an appropriate oxidizing agent such as sodium hypochlorite or calcium sulfite with oxygen under suitable conditions of pH and concentration such that oxidation and precipitation of metal oxide are sufficiently slow to allow satisfactory plating of metal oxide on the substrate. 1 fig.

  2. Composite bipolar plate for electrochemical cells

    DOEpatents

    Wilson, Mahlon S.; Busick, Deanna N.

    2001-01-01

    A bipolar separator plate for fuel cells consists of a molded mixture of a vinyl ester resin and graphite powder. The plate serves as a current collector and may contain fluid flow fields for the distribution of reactant gases. The material is inexpensive, electrically conductive, lightweight, strong, corrosion resistant, easily mass produced, and relatively impermeable to hydrogen gas. The addition of certain fiber reinforcements and other additives can improve the properties of the composite material without significantly increasing its overall cost.

  3. Plate Tectonics, Geographical Information System, paleogeography

    SciTech Connect

    Moore, Thomas L.; Scotese, Christopher

    2002-05-24

    The PaleoX.framwork is a dynamically linked/loaded framework for Cocoa applications. The primary goal of this library is to standardize several elements used for working with paleogeographic data. This includes objects designed to organize information for tectonic plates, including maps, rotation objects, plate names, and designations. In addition, PaleoX provides object-oriented solutions for handling standard paleogeographic file formats from the PALEOMAP Project.

  4. Method for plating with metal oxides

    DOEpatents

    Silver, Gary L.; Martin, Frank S.

    1994-08-23

    A method of plating hydrous metal oxides on at least one substrate, which method is indifferent to the electrochemical properties of the substrate, and comprises reacting metallic ions in aqueous solution with an appropriate oxidizing agent such as sodium hypochlorite or calcium sulfite with oxygen under suitable conditions of pH and concentration such that oxidation and precipitation of metal oxide are sufficiently slow to allow satisfactory plating of metal oxide on the substrate.

  5. Lighting system with heat distribution face plate

    DOEpatents

    Arik, Mehmet; Weaver, Stanton Earl; Stecher, Thomas Elliot; Kuenzler, Glenn Howard; Wolfe, Jr., Charles Franklin; Li, Ri

    2013-09-10

    Lighting systems having a light source and a thermal management system are provided. The thermal management system includes synthetic jet devices, a heat sink and a heat distribution face plate. The synthetic jet devices are arranged in parallel to one and other and are configured to actively cool the lighting system. The heat distribution face plate is configured to radially transfer heat from the light source into the ambient air.

  6. Brewster-Plate Spoiler for Laser Spectrometer

    NASA Technical Reports Server (NTRS)

    Webster, C. R.

    1986-01-01

    Oscillating Brewster plate reduces effects of unwanted interference fringes on absorption-spectroscopic measurements obtained with tuned diode lasers. Plate modulates optical-path length past several resonance peaks causing interference fringes to pass by rapidly and become blurred. Thus, fringe effects averaged out over time. Technique used at other wavelengths from ultraviolet to infrared and in spectrometers with short or long optical paths, including those with retroreflectors or multipass cells.

  7. Reconstructing Plate Motions on Europa with GPlates

    NASA Astrophysics Data System (ADS)

    Cutler, B. B.; Collins, G. C.; Prockter, L. M.; Patterson, G.; Kattenhorn, S. A.; Rhoden, A.; Cooper, C. M.

    2015-12-01

    Observations of past plate tectonic - like motions in Europa's icy lithosphere have been reported in previous studies. Quantifying the nature, age, and amount of plate motion is important for geophysical models of Europa's ice shell and for astrobiology, since subsumed pates could drive the flow of nutrients into the subsurface ocean. We have used GPlates software (Williams et al., GSA Today 2012) and a mosaic of regional-resolution Galileo SSI data from orbits E11, E15, E17, and E19 to make interactive reconstructions of both the Northern Falga region (60N, 220W) and the Castalia Macula region (0N, 225W). The advantage of this method is that plate motions are calculated on a sphere, while still maintaining the original Galileo image pieces in their proper geographic locations. Previous work on the Castalia Macula region (Patterson et al. J.Struct.Geol. 2006) and the adjacent Phaidra Linea region (Patterson and Ernst, LPSC 2011) found offsets along spreading boundaries, and then calculated the best fit finite rotations to close those offsets. Though this method is mathematically rigorous and gives a statistical goodness of fit, it is not easy to test multiple hypotheses for candidate piercing points or divisions of candidate plate boundaries. Through the interactive environment, we found that we could better account for observed offsets in this region by breaking it into 32 different plates. Patterson and Ernst broke the Phaidra region into 6 plates which exhibited nonrigid behavior, where our study breaks it into 16 rigid plates. The Northern Falga Regio area is interesting due to the potential for large amounts of subsumption of Europa's icy crust in this location. The previous reconstruction (Kattenhorn and Prockter, Nat.Geosci. 2014) was based on planar geometry, and we have replicated these results using a spherically-based reconstruction. We will present the plate maps and reconstructions for both of these regions, along with the best fit rotation poles.

  8. Tomography, the geoid and plate motions

    NASA Technical Reports Server (NTRS)

    Gable, Carl W.; O'Connell, Richard J.

    1991-01-01

    The dynamics of the earth's mantle and its relationship to mantle structure as revealed by seismic tomography, the geoid, and plate motions are discussed in a critical review of U.S. research from the period 1987-1990. Sections are devoted to plates and mantle convection; seismic anomalies, flow, and the geoid; subducted slabs and the 670-km discontinuity; the physical properties of the mantle; plumes; and computational and experimental modeling efforts. Also included is a comprehensive bibliography for the period.

  9. A clamped rectangular plate containing a crack

    NASA Technical Reports Server (NTRS)

    Tang, R.; Erdogan, F.

    1985-01-01

    The general problem of a rectangular plate clamped along two parallel sides and containing a crack parallel to the clamps is considered. The problem is formulated in terms of a system of singular integral equations and the asymptotic behavior of the stress state near the corners is investigated. Numerical examples are considered for a clamped plate without a crack and with a centrally located crack, and the stress intensity factors and the stresses along the clamps are calculated.

  10. Plated-through hole testing. Final repot

    SciTech Connect

    Abel, W.B.

    1980-05-01

    An improved microresistance testing method to measure the thickness of copper plating in plated-through holes of double-sided printed wiring boards is presented. A new probe design, combined with a microprocessor controller, makes it possible for a direct reading tester to provide variables data. Tester design and software programs for the system are included. Results of correlation studies, comparing the improved resistance method to cross-sectional measurements are presented. Limitations on the microresistance test method are discussed.

  11. Improved Orifice Plate for Spray Gun

    NASA Technical Reports Server (NTRS)

    Cunningham, W.

    1986-01-01

    Erratic spray pattern of commercial spray gun changed to repeatable one by simple redesign of two parts. In modified spray gun orifice plate and polytetrafluoroethylene bushing redesigned to assure centering and alignment with nozzle. Such improvement useful in many industrial applications requiring repeatable spray patterns. Might include spraying of foam insulation, paint, other protective coatings, detergents, abrasives, adhesives, process chemicals, or fuels. Unmodified spray gun produces erratic spray because lateral misalignment between orifice plate and nozzle.

  12. [Experimental study on carbon fiber reinforced plastic plate--analysis of stabilizing force required for plate].

    PubMed

    Iizuka, H

    1990-11-01

    Plates currently in use for the management of bone fracture made of metal present with various problems. We manufactured carbon fiber reinforced plastic (CFRP) plates from Pyrofil T/530 puriplegs overlaid at cross angles of +/- 10 degrees, +/- 20 degrees, and +/- 30 degrees for trial and carried out an experimental study on rabbit tibiofibular bones using 316L stainless steel plates of comparable shape and size as controls. The results indicate the influence of CFRP plate upon cortical bone was milder than that of stainless steel plate, with an adequate stabilizing force for the repair of fractured rabbit tibiofibular bones. CFRP has the advantages over metals of being virtually free from corrosion and fatigue, reasonably radiolucent and able to meet a wide range of mechanical requirements. This would make CFRP plate quite promising as a new devices of treating fracture of bones. PMID:2273322

  13. Image simulation for automatic license plate recognition

    NASA Astrophysics Data System (ADS)

    Bala, Raja; Zhao, Yonghui; Burry, Aaron; Kozitsky, Vladimir; Fillion, Claude; Saunders, Craig; Rodríguez-Serrano, José

    2012-01-01

    Automatic license plate recognition (ALPR) is an important capability for traffic surveillance applications, including toll monitoring and detection of different types of traffic violations. ALPR is a multi-stage process comprising plate localization, character segmentation, optical character recognition (OCR), and identification of originating jurisdiction (i.e. state or province). Training of an ALPR system for a new jurisdiction typically involves gathering vast amounts of license plate images and associated ground truth data, followed by iterative tuning and optimization of the ALPR algorithms. The substantial time and effort required to train and optimize the ALPR system can result in excessive operational cost and overhead. In this paper we propose a framework to create an artificial set of license plate images for accelerated training and optimization of ALPR algorithms. The framework comprises two steps: the synthesis of license plate images according to the design and layout for a jurisdiction of interest; and the modeling of imaging transformations and distortions typically encountered in the image capture process. Distortion parameters are estimated by measurements of real plate images. The simulation methodology is successfully demonstrated for training of OCR.

  14. Abrupt plate accelerations shape rifted continental margins.

    PubMed

    Brune, Sascha; Williams, Simon E; Butterworth, Nathaniel P; Müller, R Dietmar

    2016-08-11

    Rifted margins are formed by persistent stretching of continental lithosphere until breakup is achieved. It is well known that strain-rate-dependent processes control rift evolution, yet quantified extension histories of Earth's major passive margins have become available only recently. Here we investigate rift kinematics globally by applying a new geotectonic analysis technique to revised global plate reconstructions. We find that rifted margins feature an initial, slow rift phase (less than ten millimetres per year, full rate) and that an abrupt increase of plate divergence introduces a fast rift phase. Plate acceleration takes place before continental rupture and considerable margin area is created during each phase. We reproduce the rapid transition from slow to fast extension using analytical and numerical modelling with constant force boundary conditions. The extension models suggest that the two-phase velocity behaviour is caused by a rift-intrinsic strength--velocity feedback, which can be robustly inferred for diverse lithosphere configurations and rheologies. Our results explain differences between proximal and distal margin areas and demonstrate that abrupt plate acceleration during continental rifting is controlled by the nonlinear decay of the resistive rift strength force. This mechanism provides an explanation for several previously unexplained rapid absolute plate motion changes, offering new insights into the balance of plate driving forces through time. PMID:27437571

  15. Vibration analysis of annular-like plates

    NASA Astrophysics Data System (ADS)

    Cheng, L.; Li, Y. Y.; Yam, L. H.

    2003-05-01

    The existence of eccentricity of the central hole for an annular plate results in a significant change in the natural frequencies and mode shapes of the structure. In this paper, the vibration analysis of annular-like plates is presented based on numerical and experimental approaches. Using the finite element analysis code Nastran, the effects of the eccentricity, hole size and boundary condition on vibration modes are investigated systematically through both global and local analyses. The results show that analyses for perfect symmetric conditions can still roughly predict the mode shapes of "recessive" modes of the plate with a slightly eccentric hole. They will, however, lead to erroneous results for "dominant" modes. In addition, the residual displacement mode shape is verified as an effective parameter for identifying damage occurring in plate-like structures. Experimental modal analysis on a clamped-free annular-like plate is performed, and the results obtained reveal good agreement with those obtained by numerical analysis. This study provides guidance on modal analysis, vibration measurement and damage detection of plate-like structures.

  16. The planar jet-plate oscillator

    NASA Astrophysics Data System (ADS)

    Arthurs, David; Ziada, Samir

    2011-01-01

    The aeroacoustic noise generated by a high speed, planar gas jet impinging on a flat plate is investigated experimentally. The jet used in this study is typical of those commonly found in industrial applications such as in various coating control and heat transfer processes. Normal jet impingement on the plate is found to generate strong acoustic tones over a wide range of impingement distances and jet velocities. The characteristics of these tones, as a function of the jet velocity and impingement distance, are quantified. Phase and amplitude measurements of the pressure fluctuations on the impingement plate indicate that the acoustic tones are generated by an antisymmetric instability mode of the jet oscillation. The effect of plate inclination in both the transverse and span-wise directions, with respect to the incident jet, is also studied. The jet-plate tone is found to be much more sensitive to changes in the span-wise plate inclination than to changes in the transverse inclination, but in both cases, a complete suppression of the tone is found to be possible.

  17. Quantitative assessment of growth plate activity

    SciTech Connect

    Harcke, H.T.; Macy, N.J.; Mandell, G.A.; MacEwen, G.D.

    1984-01-01

    In the immature skeleton the physis or growth plate is the area of bone least able to withstand external forces and is therefore prone to trauma. Such trauma often leads to premature closure of the plate and results in limb shortening and/or angular deformity (varus or valgus). Active localization of bone seeking tracers in the physis makes bone scintigraphy an excellent method for assessing growth plate physiology. To be most effective, however, physeal activity should be quantified so that serial evaluations are accurate and comparable. The authors have developed a quantitative method for assessing physeal activity and have applied it ot the hip and knee. Using computer acquired pinhole images of the abnormal and contralateral normal joints, ten regions of interest are placed at key locations around each joint and comparative ratios are generated to form a growth plate profile. The ratios compare segmental physeal activity to total growth plate activity on both ipsilateral and contralateral sides and to adjacent bone. In 25 patients, ages 2 to 15 years, with angular deformities of the legs secondary to trauma, Blount's disease, and Perthes disease, this technique is able to differentiate abnormal segmental physeal activity. This is important since plate closure does not usually occur uniformly across the physis. The technique may permit the use of scintigraphy in the prediction of early closure through the quantitative analysis of serial studies.

  18. Utilization of urethral plate in hypospadias surgery

    PubMed Central

    Snodgrass, Warren T.

    2008-01-01

    Purpose Recognition the urethral plate comprises tissues that normally should have created the urethra was an important milestone in hypospadias surgery, giving rise to new operative repairs - most notably the tubularized incised plate technique. This article reviews the current state of the art for hypospadias repair using tubularized, incised plate (TIP). Materials and Methods Personal experience and literature reports were reviewed to summarize use of TIP urethroplasty for distal, proximal, and re-operative hypospadias repairs. Results The TIP can be used to correct all distal and most proximal hypospadias. The major contraindication is ventral curvature that leads to urethral plate transection for straightening, which is only necessary in some proximal cases. Reoperations can also be performed using TIP provided the urethral plate has been maintained and is not grossly scarred. Complication rates are comparable to previously used techniques, while cosmetic appearance after TIP is considered superior to other available procedures. Conclusions Recognition of the urethral plate and its incorporation into the neourethra has revolutionized hypospadias repair. The most commonly used operative procedure today is TIP. PMID:19468397

  19. Data analysis for surface plate calibration

    SciTech Connect

    Burton, R.N.

    1997-08-01

    A surface plate is used to establish a reference plane used for making precision dimensional measurements. Ideally, the surface should be perfectly flat. Since it is impossible to create a perfectly flat surface, surface plate are calibrated to determine how much they deviate from a perfectly flat surface. Once a surface plate is calibrated, the user can determine if the plate is flat enough for use in a particular application. The currently accepted method of data analysis for surface plate calibration, the Moody method, does not give optimum results because of the arbitrary way in which the reference plane is chosen. The exact solution, wherein the reference plane is located in the optimum position, has been worked out and is given in a step by step procedure along with all of the necessary equations. The amount of calculation involved in a typical example proved to be prohibitive even for a computer, so an alternate solution using a least squares criterion for locating the reference plane was developed. Results were comparable with those from Moody`s method with values being smaller or greater depending on the shape of the plate.

  20. Corrosion test cell for bipolar plates

    DOEpatents

    Weisbrod, Kirk R.

    2002-01-01

    A corrosion test cell for evaluating corrosion resistance in fuel cell bipolar plates is described. The cell has a transparent or translucent cell body having a pair of identical cell body members that seal against opposite sides of a bipolar plate. The cell includes an anode chamber and an cathode chamber, each on opposite sides of the plate. Each chamber contains a pair of mesh platinum current collectors and a catalyst layer pressed between current collectors and the plate. Each chamber is filled with an electrolyte solution that is replenished with fluid from a much larger electrolyte reservoir. The cell includes gas inlets to each chamber for hydrogen gas and air. As the gases flow into a chamber, they pass along the platinum mesh, through the catalyst layer, and to the bipolar plate. The gas exits the chamber through passageways that provide fluid communication between the anode and cathode chambers and the reservoir, and exits the test cell through an exit port in the reservoir. The flow of gas into the cell produces a constant flow of fresh electrolyte into each chamber. Openings in each cell body is member allow electrodes to enter the cell body and contact the electrolyte in the reservoir therein. During operation, while hydrogen gas is passed into one chamber and air into the other chamber, the cell resistance is measured, which is used to evaluate the corrosion properties of the bipolar plate.

  1. Variational modeling of ionic polymer plate structures

    NASA Astrophysics Data System (ADS)

    Buechler, Miles A.; Leo, Donald J.

    2006-03-01

    Ionomeric polymers are a promising class of intelligent material which exhibit electromechanical coupling similar to that of piezoelectric bimorphs. Ionomeric polymers are much more compliant than piezoelectric ceramics or polymers and have been shown to produce actuation strain on the order of 5% at operating voltages between 1 V and 5 V. This performance indicates the potential for self-actuating devices manufactured from ionomeric polymers, such as deformable mirrors or low pressure pump diaphragms. This paper presents a variational approach to the dynamic modeling of ionic polymer plates in rectangular coordinates. A linear matrix equation, which relates displacement and charge to applied forces and voltage, is developed to determine the response of the structure to applied forces and applied potentials. The modeling method is based on the incorporation of empirically determined material properties, which have been shown to be highly frequency dependent. The matrices are calculated at discrete frequencies and solved frequency-by-frequency to determine the response of the ionomeric plate structures. A model of a thin rectangular plate is developed and validated experimentally. Simulated frequency response functions are compared to experimental results for several locations on the plate. The response of the plate at certain frequencies is computed and compared to experimentally-determined response shapes. The results demonstrate the validity of the modeling approach in predicting the dynamic response of the ionomeric plate structure. These spatial solutions are also compared to experimentally determined response shapes.

  2. Thermal stresses and deflections of cross-ply laminated plates using refined plate theories

    SciTech Connect

    Khdeir, A.A.; Reddy, J.N. Virginia Polytechnic Institute and State University, Blacksburg )

    1991-12-01

    Exact analytical solutions of refined plate theories are developed to study the thermal stresses and deflections of cross-ply rectangular plates. The state-space approach in conjunction with the Levy method is used to solve exactly the governing equations of the theories under various boundary conditions. Numerical results of the higher-order theory of Reddy for thermal stresses and deflections are compared with those obtained using the classical and first-order plate theories. 14 refs.

  3. Current plate velocities relative to the hotspots incorporating the NUVEL-1 global plate motion model

    SciTech Connect

    Gripp, A.E.; Gordon, R.G. )

    1990-07-01

    NUVEL-1 is a new global model of current relative plate velocities which differ significantly from those of prior models. Here the authors incorporate NUVEL-1 into HS2-NUVEL1, a new global model of plate velocities relative to the hotspots. HS2-NUVEL1 was determined from the hotspot data and errors used by Minster and Jordan (1978) to determine AM1-2, which is their model of plate velocities relative to the hotspots. AM1-2 is consistent with Minster and Jordan's relative plate velocity model RM2. Here the authors compare HS2-NUVEL1 with AM1-2 and examine how their differences relate to differences between NUVEL-1 and RM2. HS2-NUVEL1 plate velocities relative to the hotspots are mainly similar to those of AM1-2. Minor differences between the two models include the following: (1) in HS2-NUVEL1 the speed of the partly continental, apparently non-subducting Indian plate is greater than that of the purely oceanic, subducting Nazca plate; (2) in places the direction of motion of the African, Antarctic, Arabian, Australian, Caribbean, Cocos, Eurasian, North American, and South American plates differs between models by more than 10{degree}; (3) in places the speed of the Australian, Caribbean, Cocos, Indian, and Nazca plates differs between models by more than 8 mm/yr. Although 27 of the 30 RM2 Euler vectors differ with 95% confidence from those of NUVEL-1, only the AM1-2 Arabia-hotspot and India-hotspot Euler vectors differ with 95% confidence from those of HS2-NUVEL1. Thus, substituting NUVEL-1 for RM2 in the inversion for plate velocities relative to the hotspots changes few Euler vectors significantly, presumably because the uncertainty in the velocity of a plate relative to the hotspots is much greater than the uncertainty in its velocity relative to other plates.

  4. The Philippine Sea Plate: Magnetism and reconstructions

    NASA Astrophysics Data System (ADS)

    Hall, Robert; Fuller, Michael; Ali, Jason R.; Anderson, Charles D.

    Paleomagnetic results from ocean drilling and from land on the Philippine Sea Plate indicate progressive northward translation of the entire plate during the Tertiary, although different sites suggest different ages of equatorial crossing. The difficulty of orienting ocean drilling cores has recently been remedied and Ocean Drilling Program leg 126 provided the first Philippine Sea Plate declination data from sea bottom sites. These showed large clockwise declination shifts of up to -90° since the early Oligocene. Similar large declination shifts have been reported from land sites at the eastern margin of the plate; these record similar changes in inclinations with age as ocean drilling sites. The cause of the declination deflections is controversial and they have been explained as the result of entire plate rotation, marginal basin opening, and/or local tectonic deformation at the plate edge. Because most declination data have been obtained from the eastern margin of the plate, it has proved impossible to distinguish between these three possible causes. However, new paleomagnetic data from land sites in the southern part of the Philippine Sea Plate in eastern Indonesia define two sub-areas: a region within the Sorong fault system that records variable rotations attributed to deformation at the plate edge, and a region north of the Sorong fault that records a large Tertiary, but discontinuous, clockwise rotation. Both areas record northward paleolatitude shifts with decreasing age since the beginning of the Neogene but inclinations of lower Eocene sites suggest southward movement during the Paleogene. We consider the area north of the Sorong fault to form one of the oldest parts of the plate and assume that the declination shifts record the Tertiary rotation of the western part of the plate. Using this assumption it is possible to calculate rotation poles and reconstruct the Philippine Sea Plate after calculating the rotational effects of opening the marginal

  5. In vitro antibacterial potency of Butea monosperma Lam. against 12 clinically isolated multidrug resistant bacteria

    PubMed Central

    Sahu, Mahesh Chandra; Padhy, Rabindra Nath

    2013-01-01

    Objective To investigate the antibacterial activity, using cold and hot extraction procedures with five solvents, petroleum ether, acetone, ethanol, methanol and water to validate medicinal uses of Butea monosperma Lam (B. monosperma) in controlling infections; and to qualitatively estimate phytochemical constituents of leaf-extracts of the plant. Methods The antibacterial activity of leaf-extracts was evaluated by the agar-well diffusion method against clinically isolated 12 Gram-positive and -negative multidrug resistant (MDR) pathogenic bacteria in vitro. Values of minimum inhibitory concentration (MIC) and minimum bactericidal concentration (MBC) of leaf-extracts against each bacterium were obtained in a 96-well micro-titre plate, by broth dilution micro-titre plate technique. Results The presence of tannins, flavonoids, starch, glycosides and carbohydrates in different leaf extracts was established. Pathogenic bacteria used were, Acinetobacter sp., Chromobacterium violaceum, Citrobacter freundii, Escherichia coli, Klebsiella pneumoniae, Pseudomonas aeruginosa, Salmonella typhi, Shigella sp., Enterococcus sp., Staphylococcus aureus (S. aureus), methicillin resistant S. aureus and vancomycin resistant S. aureus, along with standard bacterial strains. These MDR bacteria had been recorded to have significant inhibitions by leaf extracts, obtained by cold and hot extraction procedures with five solvents. In addition, the hot aqueous extract against Enterococcus sp. had the highest inhibition zone-size (21 mm). Ciprofloxacin 30 µg/disc was the positive/reference control and the diluting solvent, 10% dimethyl sulphoxide was the negative control. Recorded MIC values of different extracts ranged between 0.23 and 13.30 mg/mL, and MBC values were 0.52 to 30.00 mg/mL, for these bacteria. Conclusions Leaf-extracts with hot water and ethanol had shown significant antibacterial activity against all bacteria. B. monosperma leaf-extract could be used in treating infectious

  6. Drug absorption in vitro model: filter-immobilized artificial membranes. 2. Studies of the permeability properties of lactones in Piper methysticum Forst.

    PubMed

    Avdeef, A; Strafford, M; Block, E; Balogh, M P; Chambliss, W; Khan, I

    2001-12-01

    The assessment of transport properties of 23 drug and natural product molecules was made using the in vitro model based on filter-immobilized artificial membranes (filter-IAM), assembled from phosphatidylcholine in dodecane, in buffer solutions at pH 7.4. Five of the compounds were lactones extracted from the roots of the kava-kava plant. Experiments were designed to test the effects of stirring (0-600 rpm) during assays and the effects of varying the assay times (2-15 h). The highly mobile kava lactones permeated in the order dihydromethisticin (40)>yangonin (37)>kavain (34)>methisticin (32)>desmethoxyyangonin (26), the numbers in parentheses being the measured effective permeabilities in units of 10(-6) cm/s. By comparison, commercial drugs ranked: phenazopyridine (35)>testosterone (19)>propranolol (13)>ketoconazole (6.3)>piroxicam (2.2)>caffeine (1.7)>metoprolol (0.8)>terbutaline (0.01). In addition to permeability measurements, membrane retention of compounds was determined. Yangonin, desmethoxyyangonin, ketoconazole, and phenazopyridine were more than 60% retained by the artificial membranes containing phospholipids. Stirring during assay significantly increased the observed permeabilities for highly mobile molecules, but had minimal impact on the poorly permeable molecules. The influence of hydrogen bonding was explored by determining permeabilities using filters coated with dodecane free of phospholipids. In the filter-IAM method, concentrations were determined by microtitre plate UV spectrophotometry and by LC-MS. Higher-throughput was achieved with direct UV by the use of 96-well microtitre plate formats and with LC-MS by the use of cassette dosing (five-in-one). PMID:11684401

  7. Lateral plate number in low-plated threespine stickleback: a study of plasticity and heritability.

    PubMed

    Hansson, Truls H; Fischer, Barbara; Mazzarella, Anna B; Voje, Kjetil L; Vøllestad, Leif Asbjørn

    2016-05-01

    In the threespine stickleback Gasterosteus aculeatus model system, phenotypes are often classified into three morphs according to lateral plate number. Morph identity has been shown to be largely genetically determined, but substantial within-morph variation in plate number exists. In this study, we test whether plate number has a plastic component in response to salinity in the low-plated morph using a split-clutch experiment where families were split in two, one half raised in water at 0 and the other at 30 ppt salt. We find a small salinity-induced plastic effect on plate number in an unexpected direction, opposite to what we predicted: Fish raised in freshwater on average have slightly more plates than fish raised in saltwater. Our results confirm that heritability of plate number is high. Additionally, we find that variance in plate number at the family level can be predicted from other family level traits, which might indicate that epistatic interactions play a role in creating the observed pattern of lateral plate number variation. PMID:27096076

  8. The motion induced between radial extensional plates with one or both plates shrinking

    NASA Astrophysics Data System (ADS)

    Weidman, Patrick; Perocco, Enrico

    2015-11-01

    Flow between the radial extensional motion of parallel plates is studied when one plate stretches at rate a while the other shrinks at rate b, and also when both plates shrink. The flow is governed by the stretching ratio σ = b / | a | and the Reynolds number R = | a | h2 / ν , where h is the plate separation distance and ν is the fluid kinematic viscosity. When both plates shrink one can find solutions in the region σ < - 1 from those found in the region - 1 <= σ <= 0 . This feature is not available when one plate stretches and the other shrinks, and thus σ must be varied over the region σ <= 0 . The R = 0 solutions and their large- R asymptotic behaviors are determined. Using two numerical techniques, no bifurcated solutions were encountered. Results are presented for upper and lower wall shear stresses, radial pressure gradients, and radial velocity profiles for these axisymmetric flows. A region of zero wall shear stress exists for stretching/shrinking plates whilst the wall shear stresses for shrinking/shrinking plates are never zero. An interesting singular limit in solution behavior as R --> ∞ is found for the shrinking/shrinking plate flow.

  9. Assumed strain distributions for a finite strip plate bending element using Mindlin-Reissner plate theory

    NASA Technical Reports Server (NTRS)

    Chulya, Abhisak; Mullen, Robert L.

    1989-01-01

    A linear finite strip plate element based on Mindlin-Reissner plate theory is developed. The analysis is suitable for both thin and thick plates. In the formulation, new transverse shear strains are introduced and assumed constant in each two-node linear strip. The element stiffness matrix is explicitly formulated for efficient computation and computer implementation. Numerical results showing the efficiency and predictive capability of the element for the analysis of plates are presented for different support and loading conditions and a wide range of thicknesses. No sign of shear locking is observed with the newly developed element.

  10. The present-day number of tectonic plates

    NASA Astrophysics Data System (ADS)

    Harrison, Christopher G. A.

    2016-03-01

    The number of tectonic plates on Earth described in the literature has expanded greatly since the start of the plate tectonic era, when only about a dozen plates were considered in global models of present-day plate motions. With new techniques of more accurate earthquake epicenter locations, modern ways of measuring ocean bathymetry using swath mapping, and the use of space based geodetic techniques, there has been a huge growth in the number of plates thought to exist. The study by Bird (2003) proposed 52 plates, many of which were delineated on the basis of earthquake locations. Because of the pattern of areas of these plates, he suggested that there should be more small plates than he could identify. In this paper, I gather together publications that have proposed a total of 107 new plates, giving 159 plates in all. The largest plate (Pacific) is about 20 % of the Earth's area or 104 Mm2, and the smallest of which (Plate number 5 from Hammond et al. 2011) is only 273 km2 in area. Sorting the plates by size allows us to investigate how size varies as a function of order. There are several changes of slope in the plots of plate number organized by size against plate size order which are discussed. The sizes of the largest seven plates is constrained by the area of the Earth. A middle set of 73 plates down to an area of 97,563 km2 (the Danakil plate at number 80, is the plate of median size) follows a fairly regular pattern of plate size as a function of plate number. For smaller plates, there is a break in the slope of the plate size/plate number plot and the next 32 plates follow a pattern of plate size proposed by the models of Koehn et al. (2008) down to an area of 11,638 km2 (West Mojave plate # 112). Smaller plates do not follow any regular pattern of area as a function of plate number, probably because we have not sampled enough of these very small plates to reveal any clear pattern.

  11. Electroless Nickel Phosphorus Plating on AZ31

    NASA Astrophysics Data System (ADS)

    Shartal, Kh. M.; Kipouros, G. J.

    2009-04-01

    One of the major drawbacks to using magnesium parts in automotive applications is poor corrosion resistance, which can be improved with a nickel-boron coating placed on a nickel-phosphorus coating, which, in turn, is placed on a phosphate-permanganate conversion-coating layer produced on the magnesium alloy AZ31. This work reports on the determination of the optimum kinetic parameters for producing a coherent nickel-phosphorus coating using an electroless-procedure phosphate-permanganate conversion-coating layer and for studying the effects of the experimental variables of the electroless plating process on the phosphorus content, surface morphology, and structure of the electroless nickel-phosphorus (EN-P) coatings produced. Measurements of the plating rate as a function of experimental variables such as the compositions of the plating bath constituents, temperature, and pH were implemented using the weight-gain method; the phosphorus content of the EN-P coatings was measured using energy-dispersive spectroscopy (EDS) analysis. The surface morphology of the coating was examined using a scanning electron microscope (SEM); X-ray diffraction (XRD) was used to characterize the structure of each coating. An empirical rate law was determined for EN-P plating on a phosphate-permanganate conversion coating. It is found that the deposition rate of the EN-P coating increases by increasing the deposition temperature, the concentration of free nickel ions, and the concentration of hypophosphite ions in the plating bath. In addition, the deposition rate decreases by increasing both the plating bath pH and the concentration of citric acid in the plating bath.

  12. Caribbean plate tectonics from seismic tomography

    NASA Astrophysics Data System (ADS)

    Ten Brink, U. S.; Villasenor, A.

    2012-12-01

    New seismic tomography in the Caribbean shows close links between the geometry and dynamics of subducting slabs and the geology of the overriding plate. Unlike most oceanic plates, the Caribbean plate lacks identifiable seafloor magnetic anomalies and fracture zones. The plate's history has therefore been inferred primarily from land geology along the plate boundary, which is complicated by large-scale shear deformation, and from finite rotations of surrounding plates.We used more than 14 million arrival times from 300,000 earthquakes to identify P-wave velocity anomalies. We relate the anomalies to the geometry and dynamics of subducting slabs and to patterns of earthquake activity, volcanism, topographic relief, and tectonic deformation. For example, we detect two separate slabs belonging to the North and South American plates, respectively, which appear to be responsible for morphologic and tectonic differences between the arcs of the Northern (from Guadeloupe northward) and Southern (from Dominica southward) Lesser Antilles. Variations in earthquake activity between Haiti and the Dominican Republic can be explained by a change in slab geometry from an underplated slab beneath Haiti to a subducting slab under the Dominican Republic. A shallow tear in the slab may explain the anomalously deep Puerto Rico Trench and the frequent earthquake swarms there. The westward shift in volcanic activity in the Northern Lesser Antilles from the Miocene Limestone Caribbees to the present arc can be attributed to the limit on convective flow imposed by the 3-D geometry of the slab at depth. A thinned South America slab under the southern Lesser Antilles may result from traction imposed on the slab by a wide forearc wedge. Variations in tectonic deformation of northern South America could be related to the location of the Caribbean Large Igneous Province north of the Maracaibo Block.

  13. Signatures of downgoing plate-buoyancy driven subduction in Cenozoic plate motions

    NASA Astrophysics Data System (ADS)

    Goes, S.; Capitanio, F. A.; Morra, G.; Seton, M.; Giardini, D.

    2011-01-01

    The dynamics of plate tectonics are strongly related to those of subduction. To obtain a better understanding of the driving forces of subduction, we compare relations between Cenozoic subduction motions at major trenches with the trends expected for the simplest form of subduction. i.e., free subduction, driven solely by the buoyancy of the downgoing plate. In models with an Earth-like plate stiffness (corresponding to a plate-mantle viscosity contrast of 2-3 orders of magnitude), free plates subduct by a combination of downgoing plate motion and trench retreat, while the slab is draped and folded on top of the upper-lower mantle viscosity transition. In these models, the slabs sink according to their Stokes' velocities. Observed downgoing-plate motion-plate-age trends are compatible with >80% of the Cenozoic slabs sinking according to their upper-mantle Stokes' velocity, i.e., subducting-plate motion is largely driven by upper-mantle slab pull. Only in a few cases, do young plates move at velocities that require a higher driving force (possibly supplied by lower-mantle-slab induced flow). About 80% of the Cenozoic trenches retreat, with retreat accounting for about 10% of the total convergence. The few advancing trench sections are likely affected by regional factors. The low trench motions are likely encouraged by low asthenospheric drag (equivalent to that for effective asthenospheric viscosity 2-3 orders below the upper-mantle average), and low lithospheric strength (effective bending viscosity ˜2 orders of magnitude above the upper-mantle average). Total Cenozoic trench motions are often very oblique to the direction of downgoing-plate motion (mean angle of 73°). This indicates that other forces than slab buoyancy exert the main control on upper-plate/trench motion. However, the component of trench retreat in the direction of downgoing plate motion (≈ slab pull) correlates with downgoing-plate motion, and this component of retreat generally does not

  14. Towards modelling the evolution of intra plate stress: the Eurasian plate 20 Ma.

    NASA Astrophysics Data System (ADS)

    Quéré, Sandrine; Ruckstuhl, Karin; Wortel, Rinus; Govers, Rob; Hochard, Cyril; Stampfli, Gérard

    2010-05-01

    In this study, we investige the evolution of the intra plate stress field. We use the classical characterisation of forces acting regionally on a plate such as 'slab pull/suction', 'ridge push' and 'mantle drag' as used by Forsyth & Uyeda (1975), Chapple & Tullis (1977) and later by Wortel et al. (1991) and Govers & Meijer (2001). So far, the interaction between the lithosphere and the underlying mantle flow was oversimplified and implemented via a coupling cœfficient in the direction of the plate motion and we propose improving this specific interaction. As the shear stress field at the base of the plates is unknown in the past, we propose using a mantle flow simulation induced by the imposition of past plate motions on top of a 3D spherical mantle convective code. To that purpose, we employ the new plate motion reconstruction developed by Stampfli et al. (2008) and a 3D convective code where plates are dynamically coupled to the mantle (Quéré & Forte, 2006). The first plate on which we apply this method is the Eurasian plate as Eurasia is a large plate with a small velocity (not attached to its own subduction zone) and the debate on the main driving forces acting on Eurasia is still going on. The stress field 20 Ma resulting from all plate tectonic forces is calculated by assuming mechanical equilibrium in an homogeneous elastic shell using the plane stress approximation. As direct stress indicators for the past are rare, the predicted paleo-stress field is compared to pertinent data from orogens and extensional basins which will provide new clues to oil exploration teams.

  15. 21 CFR 882.4030 - Skull plate anvil.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Skull plate anvil. 882.4030 Section 882.4030 Food... DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4030 Skull plate anvil. (a) Identification. A skull plate anvil is a device used to form alterable skull plates in the proper shape to...

  16. 21 CFR 882.4030 - Skull plate anvil.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Skull plate anvil. 882.4030 Section 882.4030 Food... DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4030 Skull plate anvil. (a) Identification. A skull plate anvil is a device used to form alterable skull plates in the proper shape to...

  17. 21 CFR 882.4030 - Skull plate anvil.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Skull plate anvil. 882.4030 Section 882.4030 Food... DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4030 Skull plate anvil. (a) Identification. A skull plate anvil is a device used to form alterable skull plates in the proper shape to...

  18. 21 CFR 882.4030 - Skull plate anvil.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Skull plate anvil. 882.4030 Section 882.4030 Food... DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4030 Skull plate anvil. (a) Identification. A skull plate anvil is a device used to form alterable skull plates in the proper shape to...

  19. 21 CFR 882.4030 - Skull plate anvil.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Skull plate anvil. 882.4030 Section 882.4030 Food... DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4030 Skull plate anvil. (a) Identification. A skull plate anvil is a device used to form alterable skull plates in the proper shape to...

  20. 46 CFR 154.170 - Outer hull steel plating.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 5 2014-10-01 2014-10-01 false Outer hull steel plating. 154.170 Section 154.170... Structure § 154.170 Outer hull steel plating. (a) Except as required in paragraph (b) of this section, the outer hull steel plating, including the shell and deck plating must meet the material standards of...

  1. 46 CFR 154.170 - Outer hull steel plating.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 5 2013-10-01 2013-10-01 false Outer hull steel plating. 154.170 Section 154.170... Structure § 154.170 Outer hull steel plating. (a) Except as required in paragraph (b) of this section, the outer hull steel plating, including the shell and deck plating must meet the material standards of...

  2. 46 CFR 154.170 - Outer hull steel plating.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 5 2012-10-01 2012-10-01 false Outer hull steel plating. 154.170 Section 154.170... Structure § 154.170 Outer hull steel plating. (a) Except as required in paragraph (b) of this section, the outer hull steel plating, including the shell and deck plating must meet the material standards of...

  3. 46 CFR 154.170 - Outer hull steel plating.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 5 2011-10-01 2011-10-01 false Outer hull steel plating. 154.170 Section 154.170... Structure § 154.170 Outer hull steel plating. (a) Except as required in paragraph (b) of this section, the outer hull steel plating, including the shell and deck plating must meet the material standards of...

  4. 49 CFR 451.21 - Safety approval plate required.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 6 2012-10-01 2012-10-01 false Safety approval plate required. 451.21 Section 451... HOMELAND SECURITY SAFETY APPROVAL OF CARGO CONTAINERS TESTING AND APPROVAL OF CONTAINERS Safety Approval Plate § 451.21 Safety approval plate required. (a) The safety approval plate must be supplied by...

  5. Making More Efficient Use Of Battery-Plate Mass

    NASA Technical Reports Server (NTRS)

    Rowlette, John J.

    1990-01-01

    Improved active material for positive plate of lead/acid electric storage battery made with additional porosity to give electrolyte access to larger plate-surface area. 65 to 68 percent of active mass of plate used to generate electric current. Batteries with new plate material offer extremely long cycle life.

  6. A unified theory for laminated plates

    NASA Astrophysics Data System (ADS)

    Guiamatsia Tafeuvoukeng, Irene

    A literature survey on plate and beam theories show how the advent of the finite element method and the variational method circa 1940 have been a great stimulant for the research in this field. The initial thin plate formulation has been incrementally expanded to treat the isotropic thick plate, the anisotropic single layer, and then laminated plates. It appears however that current formulations still fall into one of two categories: (1) The formulation is tailored for a specific laminate and/or loading case; (2) or the formulation is too complicated to be of practical relevance. In this work a new unifying approach to laminated plate formulation is presented. All laminated plates, including sandwich panels, subjected to any surface load and with any boundary conditions are treated within a single model. In addition, the fundamental behavior of the plate as a two-dimensional structural element is explained. The novel idea is the introduction of fundamental state solutions, which are analytical far field stress and strain solutions of the laminated plate subjected to a set of hierarchical primary loads, the fundamental loads. These loads are carefully selected to form a basis of the load space, and corresponding solutions are superposed to obtain extremely accurate predictions of the three dimensional solution. six,y,z =aklx,y sikl z where i = 1,..., 6; 1=1,...,l max is a substate of the kth fundamental state k=1,2,3,... Typically, a fundamental state solution is expressed as a through-thickness function (z), while the amplitudes of each fundamental load are found from two dimensional finite element solution as a function of in-plane coordinates (x,y). Three major contributions are produced in this work: (1) A complete calibration of the plate as a two-dimensional structure is performed with pure bending and constant shear fundamental states. (2) There are four independent ways to apply a constant shear resultant on a plate, as opposed to one for a beam. This makes

  7. Spirit Begins Drive Around Home Plate

    NASA Technical Reports Server (NTRS)

    2009-01-01

    The hazard avoidance camera on the front of NASA's Mars Exploration Rover Spirit took this image after a drive by Spirit on the 1,829th Martian day, or sol, of Spirit's mission on the surface of Mars (Feb. 24, 2009).

    On Sol 1829, Spirit drove 6.29 meters (21 feet) northwestward, away from the northern edge of the low plateau called 'Home Plate.' The track dug by the dragged right-front wheel as the rover drove backward is visible in this image, receding toward the southeast. Rock layers of the northern slope of Home Plate are visible in the upper right portion of the image.

    In sols prior to 1829, the rover team had been trying to maneuver Spirit to climb onto the northern edge of Home Plate, ready to drive southward across the top of the plateau toward science destinations south of Home Plate. The Sol 1829 drive was the first move of a revised strategy to circle at least partway around Home Plate on the trek toward the sites south of the plateau.

  8. Recovery process for electroless plating baths

    DOEpatents

    Anderson, R.W.; Neff, W.A.

    1992-05-12

    A process is described for removing, from spent electroless metal plating bath solutions, accumulated byproducts and counter-ions that have deleterious effects on plating. The solution, or a portion thereof, is passed through a selected cation exchange resin bed in hydrogen form, the resin selected from strong acid cation exchangers and combinations of intermediate acid cation exchangers with strong acid cation exchangers. Sodium and nickel ions are sorbed in the selected cation exchanger, with little removal of other constituents. The remaining solution is subjected to sulfate removal through precipitation of calcium sulfate hemihydrate using, sequentially, CaO and then CaCO[sub 3]. Phosphite removal from the solution is accomplished by the addition of MgO to form magnesium phosphite trihydrate. The washed precipitates of these steps can be safely discarded in nontoxic land fills, or used in various chemical industries. Finally, any remaining solution can be concentrated, adjusted for pH, and be ready for reuse. The plating metal can be removed from the exchanger with sulfuric acid or with the filtrate from the magnesium phosphite precipitation forming a sulfate of the plating metal for reuse. The process is illustrated as applied to processing electroless nickel plating baths. 18 figs.

  9. Recovery process for electroless plating baths

    DOEpatents

    Anderson, Roger W.; Neff, Wayne A.

    1992-01-01

    A process for removing, from spent electroless metal plating bath solutions, accumulated byproducts and counter-ions that have deleterious effects on plating. The solution, or a portion thereof, is passed through a selected cation exchange resin bed in hydrogen form, the resin selected from strong acid cation exchangers and combinations of intermediate acid cation exchangers with strong acid cation exchangers. Sodium and nickel ions are sorbed in the selected cation exchanger, with little removal of other constituents. The remaining solution is subjected to sulfate removal through precipitation of calcium sulfate hemihydrate using, sequentially, CaO and then CaCO.sub.3. Phosphite removal from the solution is accomplished by the addition of MgO to form magnesium phosphite trihydrate. The washed precipitates of these steps can be safely discarded in nontoxic land fills, or used in various chemical industries. Finally, any remaining solution can be concentrated, adjusted for pH, and be ready for reuse. The plating metal can be removed from the exchanger with sulfuric acid or with the filtrate from the magnesium phosphite precipitation forming a sulfate of the plating metal for reuse. The process is illustrated as applied to processing electroless nickel plating baths.

  10. Flow structure on a rotating plate

    NASA Astrophysics Data System (ADS)

    Ozen, C. A.; Rockwell, D.

    2012-01-01

    The flow structure on a rotating plate of low aspect ratio is characterized well after the onset of motion, such that transient effects are not significant, and only centripetal and Coriolis accelerations are present. Patterns of vorticity, velocity contours, and streamline topology are determined via quantitative imaging, in order to characterize the leading-edge vortex in relation to the overall flow structure. A stable leading-edge vortex is maintained over effective angles of attack from 30° to 75°, and at each angle of attack, its sectional structure at midspan is relatively insensitive to Reynolds number over the range from 3,600 to 14,500. The streamline topology, vorticity distribution, and circulation of the leading-edge vortex are determined as a function of angle of attack, and related to the velocity field oriented toward, and extending along, the leeward surface of the plate. The structure of the leading-edge vortex is classified into basic regimes along the span of the plate. Images of these regimes are complemented by patterns on crossflow planes, which indicate the influence of root and tip swirl, and spanwise flow along the leeward surface of the plate. Comparison with the equivalent of the purely translating plate, which does not induce the foregoing flow structure, further clarifies the effects of rotation.

  11. Computer animation of Phanerozoic plate motions

    SciTech Connect

    Scotese, C.R. . Dept. of Geology)

    1992-01-01

    Since 1985, the PALEOMAP Project, in collaboration with research groups both in the US and abroad, has assembled a digital model that describes global plate motions during the last 600 million years. In this paper the authors present a series of computer animations that dynamically illustrates the movement of continents and terranes, and the evolution of the ocean basins since the breakup of the late Precambrian supercontinent. These animations depict the motion of the plates from both equatorial and polar perspectives. Mesozoic and Cenozoic plate tectonic reconstructions are based on a synthesis of linear magnetic anomalies, fracture zone locations, intracontinental rifts, collision and thrust belts, and zones of strike-slip. Paleozoic plate reconstructions, though more speculative, are based on evidence of past subduction, continental collision, and inferred sea floor spreading. The relative longitudinal positions of the continents during the Paleozoic and the width of intervening oceans have been adjusted to best explain changing biogeographic and paleoclimatic patterns. A new paleomagnetic/hot spot reference frame has been constructed that combines paleomagnetic data compiled by Rob Van der Voo (1992) with inferred motion relative to a fixed frame of hot spots. Using probable Early Mesozoic and Paleozoic hot spot tracks on the major continents, the authors have extended plate motions relative to the hot spot reference frame back to 400 million years.

  12. Extreme Wave Impact on a Flexible Plate

    NASA Astrophysics Data System (ADS)

    Abraham, Aliza; Techet, Alexandra

    2015-11-01

    Digital image correlation (DIC) and particle image velocimetry (PIV) are combined to characterize the flow-structure interaction of a breaking wave impacting a flexible vertically mounted plate. DIC is used with the beam bending equation to determine the stresses on the plate and PIV is used to describe the flow of the wave. In this experiment, a simulated dam break in which water is rapidly released from a reservoir generates the wave, which impinges on a cantilevered stainless steel plate downstream. Pressure sensors mounted on the plate are used to gather further information about the forces acting on it. A series of waves of different heights and breaking locations are tested, controlled by the volume of water in the tank and the volume of water in the dam break reservoir. The deflection of the plate varies depending on the point of breaking and the height of the wave. These results shed light on the effect of breaking wave impacts on offshore structures and ship hulls.

  13. Rotary sequencing valve with flexible port plate

    DOEpatents

    Wagner, Glenn Paul

    2005-05-10

    Rotary sequencing valve comprising a rotor having a rotor face rotatable about an axis perpendicular to the rotor face, wherein the rotor face has a plurality of openings, one or more of which are disposed at a selected radial distance from the axis, and wherein the rotor includes at least one passage connecting at least one pair of the plurality of openings. The valve includes a flexible port plate having a first side and a second side, wherein the first side faces the rotor and engages the rotor such that the flexible port plate can be rotated coaxially by the rotor and can move axially with respect to the rotor, wherein the flexible port plate has a plurality of ports between the first and second sides, which ports are aligned with the openings in the rotor face. The valve also includes a stator having a stator face disposed coaxially with the rotor and the flexible port plate, wherein the second side of the flexible port plate is in sealable, slidable rotary contact with the stator face, wherein the stator face has a plurality of openings, some of which are disposed at the selected radial distance from the axis, and wherein the plurality of openings extend as passages through the stator. The valve may be used in pressure or temperature swing adsorption systems.

  14. Geometrically nonlinear behavior of piezoelectric laminated plates

    NASA Astrophysics Data System (ADS)

    Rabinovitch, Oded

    2005-08-01

    The geometrically nonlinear behavior of piezo-laminated plates actuated with isotropic or anisotropic piezoelectric layers is analytically investigated. The analytical model is derived using the variational principle of virtual work along with the lamination and plate theories, the von Karman large displacement and moderate rotation kinematic relations, and the anisotropic piezoelectric constitutive laws. A solution strategy that combines the approach of the method of lines, the advantages of the finite element concept, and the variational formulation is developed. This approach yields a set of nonlinear ordinary differential equations with nonlinear boundary conditions, which are solved using the multiple-shooting method. Convergence and verification of the model are examined through comparison with linear and nonlinear results of other approximation methods. The nonlinear response of two active plate structures is investigated numerically. The first plate is actuated in bending using monolithic piezoceramic layers and the second one is actuated in twist using macro-fiber composites. The results quantitatively reveal the complicated in-plane stress state associated with the piezoelectric actuation and the geometrically nonlinear coupling of the in-plane and out-of-plane responses of the plate. The influence of the nonlinear effects ranges from significant stiffening in certain combinations of electrical loads and boundary conditions to amplifications of the induced deflections in others. The paper closes with a summary and conclusions.

  15. Preserving and Archiving Astronomical Photographic Plates

    NASA Astrophysics Data System (ADS)

    Castelaz, M. W.; Cline, J. D.

    2005-05-01

    Astronomical objects change with time. New observations complement past observations recorded on photographic plates. Analyses of changes provide essential routes to information about an object's formation, constitution and evolution. Preserving a century of photographic plate observations is thus of paramount importance. Plate collections are presently widely dispersed; plates may be stored in poor conditions, and are effectively inaccessible to both researchers and historians. We describe a planned project at Pisgah Astronomical Research Institute to preserve the collections of astronomical plates in the United States by gathering them into a single storage location. Collections will be sorted, cleaned, and cataloged on-line so as to provide access to researchers. Full scientific and historic use of the material then requires the observations themselves to be accessible digitally. The project's goal will be the availability of these data as a unique, fully-maintained scientific and educational resource. The new archive will support trans-disciplinary research such as the chemistry of the Earth's atmosphere, library information science, trends in local weather patterns, and impacts of urbanization on telescope use, while the hand-written observatory logs will be a valuable resource for science historians and biographers.

  16. Ridge push engine of plate tectonics

    NASA Astrophysics Data System (ADS)

    Swedan, N. H.

    2015-07-01

    Convection of the upper mantle drives the tectonic plates. This convection is a thermodynamic cycle that exchanges heat and mechanical work between mantle and tectonic plates. Thermodynamics and observations indicate that the energy of the geological activities resulting from plate tectonics is equal to the latent heat of melting, calculated at mantle's pressure, of the new ocean crust regenerated at midocean ridges. This energy varies with the temperature of ocean floor, which is correlated with surface temperature. The main objective of this manuscript is to demonstrate that plate tectonics is a thermodynamic engine and can be calculated as such. Unlike existing tectonic models, the thermodynamic model is very sensitive to variations of the temperature of ocean floor, which is correlated with surface temperature. Therefore, the observed increase of geological activities can be projected with surface temperature rise. Other objectives of the manuscript are to calculate the force that drives the tectonic plates, estimate the energy released, and validate the calculations based on experiments and observations. In addition to the scientific merit of projecting the geological activities, a good projection can have a broader impact at the societal and economical levels. Investment and insurance related decisions are affected by climate change, and our ability to project the geological activities is of paramount importance for the economy and public safety. This work can thus provide tools to assess the risks and hazards associated with the trend of geological activities with surface temperature rise.

  17. Finite element analysis of advanced neutron source fuel plates

    SciTech Connect

    Luttrell, C.R.

    1995-08-01

    The proposed design for the Advanced Neutron Source reactor core consists of closely spaced involute fuel plates. Coolant flows between the plates at high velocities. It is vital that adjacent plates do not come in contact and that the coolant channels between the plates remain open. Several scenarios that could result in problems with the fuel plates are studied. Finite element analyses are performed on fuel plates under pressure from the coolant flowing between the plates at a high velocity, under pressure because of a partial flow blockage in one of the channels, and with different temperature profiles.

  18. Current plate motions. [continental groupings and global modelling

    NASA Technical Reports Server (NTRS)

    Demets, C.; Gordon, R. G.; Argus, D. F.; Stein, S.

    1990-01-01

    A global plate motion model, named NUVEL-1, which describes current plate motions between 12 rigid plates is described, with special attention given to the method, data, and assumptions used. Tectonic implications of the patterns that emerged from the results are discussed. It is shown that wide plate boundary zones can form not only within the continental lithosphere but also within the oceanic lithosphere; e.g., between the Indian and Australian plates and between the North American and South American plates. Results of the model also suggest small but significant diffuse deformation of the oceanic lithosphere, which may be confined to small awkwardly shaped salients of major plates.

  19. Finite element modeling of stress in the Nazca plate - Driving forces and plate boundary earthquakes

    NASA Technical Reports Server (NTRS)

    Richardson, R. M.

    1978-01-01

    The state of stress within the Nazca plate due to plate driving forces and large plate boundary earthquakes has been analyzed by applying a finite element method using the wave front solution technique to models of the intraplate stress field in a single plate using a refined grid. Although only static elastic models have been explicitly calculated, certain limiting cases of an elastic plate over a viscous asthenosphere were also treated. A state of nearly east-west compression inferred from the source mechanism of thrust earthquakes in the interior of the plate requires ridge pushing forces. The net pulling force on the oceanic plate by the subducted slab has a maximum value comparable to pushing forces. The estimated horizontal deviatoric stress in intraplate regions, based on potential forces associated with the ridge, is on the order of a few hundred bars. The intraplate stress field in the region of the 1960 earthquake may change by a few tens of bars at most once the asthenosphere has relaxed, with changes on the order of one bar occurring at greater distances into the plate. The changes in the intraplate stress field are probably not noticeable unless the lithosphere is near failure.

  20. Lasting mantle scars lead to perennial plate tectonics

    PubMed Central

    Heron, Philip J.; Pysklywec, Russell N.; Stephenson, Randell

    2016-01-01

    Mid-ocean ridges, transform faults, subduction and continental collisions form the conventional theory of plate tectonics to explain non-rigid behaviour at plate boundaries. However, the theory does not explain directly the processes involved in intraplate deformation and seismicity. Recently, damage structures in the lithosphere have been linked to the origin of plate tectonics. Despite seismological imaging suggesting that inherited mantle lithosphere heterogeneities are ubiquitous, their plate tectonic role is rarely considered. Here we show that deep lithospheric anomalies can dominate shallow geological features in activating tectonics in plate interiors. In numerical experiments, we found that structures frozen into the mantle lithosphere through plate tectonic processes can behave as quasi-plate boundaries reactivated under far-field compressional forcing. Intraplate locations where proto-lithospheric plates have been scarred by earlier suturing could be regions where latent plate boundaries remain, and where plate tectonics processes are expressed as a ‘perennial' phenomenon. PMID:27282541

  1. Lasting mantle scars lead to perennial plate tectonics.

    PubMed

    Heron, Philip J; Pysklywec, Russell N; Stephenson, Randell

    2016-01-01

    Mid-ocean ridges, transform faults, subduction and continental collisions form the conventional theory of plate tectonics to explain non-rigid behaviour at plate boundaries. However, the theory does not explain directly the processes involved in intraplate deformation and seismicity. Recently, damage structures in the lithosphere have been linked to the origin of plate tectonics. Despite seismological imaging suggesting that inherited mantle lithosphere heterogeneities are ubiquitous, their plate tectonic role is rarely considered. Here we show that deep lithospheric anomalies can dominate shallow geological features in activating tectonics in plate interiors. In numerical experiments, we found that structures frozen into the mantle lithosphere through plate tectonic processes can behave as quasi-plate boundaries reactivated under far-field compressional forcing. Intraplate locations where proto-lithospheric plates have been scarred by earlier suturing could be regions where latent plate boundaries remain, and where plate tectonics processes are expressed as a 'perennial' phenomenon. PMID:27282541

  2. Lasting mantle scars lead to perennial plate tectonics

    NASA Astrophysics Data System (ADS)

    Heron, Philip J.; Pysklywec, Russell N.; Stephenson, Randell

    2016-06-01

    Mid-ocean ridges, transform faults, subduction and continental collisions form the conventional theory of plate tectonics to explain non-rigid behaviour at plate boundaries. However, the theory does not explain directly the processes involved in intraplate deformation and seismicity. Recently, damage structures in the lithosphere have been linked to the origin of plate tectonics. Despite seismological imaging suggesting that inherited mantle lithosphere heterogeneities are ubiquitous, their plate tectonic role is rarely considered. Here we show that deep lithospheric anomalies can dominate shallow geological features in activating tectonics in plate interiors. In numerical experiments, we found that structures frozen into the mantle lithosphere through plate tectonic processes can behave as quasi-plate boundaries reactivated under far-field compressional forcing. Intraplate locations where proto-lithospheric plates have been scarred by earlier suturing could be regions where latent plate boundaries remain, and where plate tectonics processes are expressed as a `perennial' phenomenon.

  3. Performance evaluation of the R6R018 fuel plate using PLATE code

    SciTech Connect

    Pavel G. Medvedev; Hakan Ozaltun

    2010-03-01

    The paper presents results of performance evaluation of the R6R018 fuel plate using PLATE code. R6R018 is a U-7Mo dispersion type mini-plate with Al-3.5Si matrix irradiated in the RERTR-9B experiment. The design of this plate is prototypical of the planned LEONIDAS irradiation test. Therefore, a detailed performance analysis of this plate is important to confirm acceptable behavior in pile, and to provide baseline and justification for further analysis and testing. Specific results presented in the paper include fuel temperature history, growth of the interaction layer between the U-Mo and the matrix, swelling, growth of the corrosion layer, and degradation of thermal conductivity. The methodology of the analysis will be discussed including the newly developed capability to account for the formation of the interaction layer during fuel fabrication.

  4. Nonlocal third-order shear deformation plate theory with application to bending and vibration of plates

    NASA Astrophysics Data System (ADS)

    Aghababaei, Ramin; Reddy, J. N.

    2009-09-01

    The third-order shear deformation plate theory of Reddy [A simple higher-order theory for laminated composite plates, J. Appl. Mech. 51 (1984) 745-752] is reformulated using the nonlocal linear elasticity theory of Eringen. This theory has ability to capture the both small scale effects and quadratic variation of shear strain and consequently shear stress through the plate thickness. Analytical solutions of bending and free vibration of a simply supported rectangular plate are presented using this theory to illustrate the effect of nonlocal theory on deflection and natural frequency of the plates. Finally, the relations between nonlocal third-order, first-order and classical theories are discussed by numerical results.

  5. Highly conductive composites for fuel cell flow field plates and bipolar plates

    DOEpatents

    Jang, Bor Z; Zhamu, Aruna; Song, Lulu

    2014-10-21

    This invention provides a fuel cell flow field plate or bipolar plate having flow channels on faces of the plate, comprising an electrically conductive polymer composite. The composite is composed of (A) at least 50% by weight of a conductive filler, comprising at least 5% by weight reinforcement fibers, expanded graphite platelets, graphitic nano-fibers, and/or carbon nano-tubes; (B) polymer matrix material at 1 to 49.9% by weight; and (C) a polymer binder at 0.1 to 10% by weight; wherein the sum of the conductive filler weight %, polymer matrix weight % and polymer binder weight % equals 100% and the bulk electrical conductivity of the flow field or bipolar plate is at least 100 S/cm. The invention also provides a continuous process for cost-effective mass production of the conductive composite-based flow field or bipolar plate.

  6. Plate on plate osteosynthesis for the treatment of nonhealed periplate fractures.

    PubMed

    Arealis, Georgios; Nikolaou, Vassilios S; Lacon, Andrew; Ashwood, Neil; Hamlet, Mark

    2014-01-01

    Purpose. The purpose of this paper is to present our technique for the treatment of periplate fractures. Methods. From 2009 to 2012 we treated three patients. In all cases the existing plate was left and the new one placed over the existing. Locking screws were placed through both plates. The other screws in the new plate were used as best suited the fracture. Results. In all cases less than 6 months had passed between fractures. None of the original fractures had healed. Mean followup was 2 years. All fractures proceeded to union within 7 months. No complications were recorded. All the patients returned to their normal activities and were satisfied with the results of their treatment. Conclusion. Our plate on plate technique is effective for the treatment of periplate fractures. A solid fusion can be achieved at the new fracture site without disturbing the previous fixation. PMID:24967127

  7. 49 CFR 179.200-6 - Thickness of plates.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... bursting pressure in psig; S = Minimum tensile strength of plate material in p.s.i. as prescribed in § 179... strength of plate material in p.s.i. as prescribed in § 179.200-7; t = Minimum thickness of plate in inches... strength of plate material in p.s.i. as prescribed in § 179.200-7; t = Minimum thickness of plate in...

  8. 49 CFR 179.200-6 - Thickness of plates.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... bursting pressure in psig; S = Minimum tensile strength of plate material in p.s.i. as prescribed in § 179... strength of plate material in p.s.i. as prescribed in § 179.200-7; t = Minimum thickness of plate in inches... strength of plate material in p.s.i. as prescribed in § 179.200-7; t = Minimum thickness of plate in...

  9. 49 CFR 179.200-6 - Thickness of plates.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... bursting pressure in psig; S = Minimum tensile strength of plate material in p.s.i. as prescribed in § 179... strength of plate material in p.s.i. as prescribed in § 179.200-7; t = Minimum thickness of plate in inches... strength of plate material in p.s.i. as prescribed in § 179.200-7; t = Minimum thickness of plate in...

  10. 49 CFR 179.200-6 - Thickness of plates.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... bursting pressure in psig; S = Minimum tensile strength of plate material in p.s.i. as prescribed in § 179... strength of plate material in p.s.i. as prescribed in § 179.200-7; t = Minimum thickness of plate in inches... strength of plate material in p.s.i. as prescribed in § 179.200-7; t = Minimum thickness of plate in...

  11. Root-Contact/Pressure-Plate Assembly For Hydroponic System

    NASA Technical Reports Server (NTRS)

    Morris, Carlton E.; Loretan, Philip A.; Bonsi, Conrad K.; Hill, Walter A.

    1994-01-01

    Hydroponic system includes growth channels equipped with rootcontact/pressure-plate assemblies. Pump and associated plumbing circulate nutrient liquid from reservoir, along bottom of growth channels, and back to reservoir. Root-contact/pressure-plate assembly in each growth channel stimulates growth of roots by applying mild contact pressure. Flat plate and plate connectors, together constitute pressure plate, free to move upward to accommodate growth of roots. System used for growing sweetpotatoes and possibly other tuber and root crops.

  12. Optical Analyzer Technique for Spall Investigations in Metal Plates

    SciTech Connect

    Kovalenko, G. V.; Kozlov, E. A.; Nogin, V. N.; Pankratov, D. G.; Yakunin, A. K.

    2006-08-03

    Possible experimental set-up for investigation of the stage of spalls closing in plates before impact on base plate are considered. Multi-wave configurations in indicator-matter situated on the base plate are observed by optical analyzer technique. Oscillograms and results of their processing are presented. Thickness and average density of the spall layer in the plate immediately before its impact on the base plate are estimated.

  13. Microporous microchannel plates and method of manufacturing same

    DOEpatents

    Beetz, Jr., Charles P.; Boerstler, Robert W.; Steinbeck, John; Winn, David R.

    2000-01-01

    A microchannel plate and method of manufacturing same is provided. The microchannel plate includes a plate consisting of an anodized material and a plurality of channels which are formed during the anodization of the material and extend between the two sides of the plate. Electrodes are also disposed on each side of the plate for generating an electrical field within the channels. Preferably, the material is alumina and the channels are activated such that the channel walls are conductive and highly secondary emissive.

  14. Supracondylar Osteotomy in Valgus Knee: Angle Blade Plate Versus Locking Compression Plate

    PubMed Central

    Kazemi, Seyyed Morteza; Minaei, Reza; Safdari, Farshad; Keipourfard, Ali; Forghani, Rozhin; Mirzapourshafiei, Alemeh

    2016-01-01

    Background: There are few studies comparing the biomechanical properties of angled blade plate and locking compression plates in supracondylar osteotomy. In the current randomized study, we prospectively compared the clinical and radiological outcomes of supracondylar osteotomy using these two plates. Methods: Forty patients with valgus knee malalignment were randomly assigned to two equal numbered groups: angled blade plate and locking compression plates. All of the patients underwent medial closing wedge supracondylar osteotomy and were followed for one year. Before and after the operation the valgus angle and mechanical lateral distal femoral angle were compared between groups. Also, the rate of complications were compared. Results: After the operation, the mean valgus angle and mechanical lateral distal femoral angle improved significantly in the two groups (P<0.001). Although, the preoperative amount of the valgus angle and mechanical lateral distal femoral angle were the same, at the last visit the valgus angle (5.4±2.1 versus 3.1±1.8; P=0.032) and mechanical lateral distal femoral angle (87.6±2 versus 89.7±3.2; P=0.041) were significantly lower and higher in the angled blade plate group, respectively. Nonunion occurred in four patients (20%) in the locking compression plates group (P=0.35). Conclusion: Based on having a larger valgus angle and mechanical lateral distal femoral angle correction in the angled blade plate group and considerable rate of nonunion in the locking compression plate group, the authors recommend using the angled blade plate for fixation of medial closing wedge supracondylar osteotomy for patients with valgus malalignment. However, more long-term studies are required. PMID:26894215

  15. Dual fuel gradients in uranium silicide plates

    SciTech Connect

    Pace, B.W.

    1997-08-01

    Babcock & Wilcox has been able to achieve dual gradient plates with good repeatability in small lots of U{sub 3}Si{sub 2} plates. Improvements in homogeneity and other processing parameters and techniques have allowed the development of contoured fuel within the cladding. The most difficult obstacles to overcome have been the ability to evaluate the bidirectional fuel loadings in comparison to the perfect loading model and the different methods of instilling the gradients in the early compact stage. The overriding conclusion is that to control the contour of the fuel, a known relationship between the compact, the frames and final core gradient must exist. Therefore, further development in the creation and control of dual gradients in fuel plates will involve arriving at a plausible gradient requirement and building the correct model between the compact configuration and the final contoured loading requirements.

  16. Flow of nanofluid past a Riga plate

    NASA Astrophysics Data System (ADS)

    Ahmad, Adeel; Asghar, Saleem; Afzal, Sumaira

    2016-03-01

    This paper studies the mixed convection boundary layer flow of a nanofluid past a vertical Riga plate in the presence of strong suction. The mathematical model incorporates the Brownian motion and thermophoresis effects due to nanofluid and the Grinberg-term for the wall parallel Lorentz force due to Riga plate. The analytical solution of the problem is presented using the perturbation method for small Brownian and thermophoresis diffusion parameters. The numerical solution is also presented to ensure the reliability of the asymptotic method. The comparison of the two solutions shows an excellent agreement. The correlation expressions for skin friction, Nusselt number and Sherwood number are developed by performing linear regression on the obtained numerical data. The effects of nanofluid and the Lorentz force due to Riga plate, on the skin friction are discussed.

  17. Astrometric properties of the Tautenburg Plate Scanner

    NASA Astrophysics Data System (ADS)

    Brunzendorf, Jens; Meusinger, Helmut

    The Tautenburg Plate Scanner (TPS) is an advanced plate-measuring machine run by the Thüringer Landessternwarte Tautenburg (Karl Schwarzschild Observatory), where the machine is housed. It is capable of digitising photographic plates up to 30 cm × 30 cm in size. In our poster, we reported on tests and preliminary results of its astrometric properties. The essential components of the TPS consist of an x-y table movable between an illumination system and a direct imaging system. A telecentric lens images the light transmitted through the photographic emulsion onto a CCD line of 6000 pixels of 10 µm square size each. All components are mounted on a massive air-bearing table. Scanning is performed in lanes of up to 55 mm width by moving the x-y table in a continuous drift-scan mode perpendicular to the CCD line. The analogue output from the CCD is digitised to 12 bit with a total signal/noise ratio of 1000 : 1, corresponding to a photographic density range of three. The pixel map is produced as a series of optionally overlapping lane scans. The pixel data are stored onto CD-ROM or DAT. A Tautenburg Schmidt plate 24 cm × 24 cm in size is digitised within 2.5 hours resulting in 1.3 GB of data. Subsequent high-level data processing is performed off-line on other computers. During the scanning process, the geometry of the optical components is kept fixed. The optimal focussing of the optics is performed prior to the scan. Due to the telecentric lens refocussing is not required. Therefore, the main source of astrometric errors (beside the emulsion itself) are mechanical imperfections in the drive system, which have to be divided into random and systematic ones. The r.m.s. repeatability over the whole plate as measured by repeated scans of the same plate is about 0.5 µm for each axis. The mean plate-to-plate accuracy of the object positions on two plates with the same epoch and the same plate centre has been determined to be about 1 µm. This accuracy is comparable to

  18. Plate tectonics drive tropical reef biodiversity dynamics

    PubMed Central

    Leprieur, Fabien; Descombes, Patrice; Gaboriau, Théo; Cowman, Peter F.; Parravicini, Valeriano; Kulbicki, Michel; Melián, Carlos J.; de Santana, Charles N.; Heine, Christian; Mouillot, David; Bellwood, David R.; Pellissier, Loïc

    2016-01-01

    The Cretaceous breakup of Gondwana strongly modified the global distribution of shallow tropical seas reshaping the geographic configuration of marine basins. However, the links between tropical reef availability, plate tectonic processes and marine biodiversity distribution patterns are still unknown. Here, we show that a spatial diversification model constrained by absolute plate motions for the past 140 million years predicts the emergence and movement of diversity hotspots on tropical reefs. The spatial dynamics of tropical reefs explains marine fauna diversification in the Tethyan Ocean during the Cretaceous and early Cenozoic, and identifies an eastward movement of ancestral marine lineages towards the Indo-Australian Archipelago in the Miocene. A mechanistic model based only on habitat-driven diversification and dispersal yields realistic predictions of current biodiversity patterns for both corals and fishes. As in terrestrial systems, we demonstrate that plate tectonics played a major role in driving tropical marine shallow reef biodiversity dynamics. PMID:27151103

  19. Numerical modelling of instantaneous plate tectonics

    NASA Technical Reports Server (NTRS)

    Minster, J. B.; Haines, E.; Jordan, T. H.; Molnar, P.

    1974-01-01

    Assuming lithospheric plates to be rigid, 68 spreading rates, 62 fracture zones trends, and 106 earthquake slip vectors are systematically inverted to obtain a self-consistent model of instantaneous relative motions for eleven major plates. The inverse problem is linearized and solved iteratively by a maximum-likelihood procedure. Because the uncertainties in the data are small, Gaussian statistics are shown to be adequate. The use of a linear theory permits (1) the calculation of the uncertainties in the various angular velocity vectors caused by uncertainties in the data, and (2) quantitative examination of the distribution of information within the data set. The existence of a self-consistent model satisfying all the data is strong justification of the rigid plate assumption. Slow movement between North and South America is shown to be resolvable.

  20. Plate tectonics drive tropical reef biodiversity dynamics.

    PubMed

    Leprieur, Fabien; Descombes, Patrice; Gaboriau, Théo; Cowman, Peter F; Parravicini, Valeriano; Kulbicki, Michel; Melián, Carlos J; de Santana, Charles N; Heine, Christian; Mouillot, David; Bellwood, David R; Pellissier, Loïc

    2016-01-01

    The Cretaceous breakup of Gondwana strongly modified the global distribution of shallow tropical seas reshaping the geographic configuration of marine basins. However, the links between tropical reef availability, plate tectonic processes and marine biodiversity distribution patterns are still unknown. Here, we show that a spatial diversification model constrained by absolute plate motions for the past 140 million years predicts the emergence and movement of diversity hotspots on tropical reefs. The spatial dynamics of tropical reefs explains marine fauna diversification in the Tethyan Ocean during the Cretaceous and early Cenozoic, and identifies an eastward movement of ancestral marine lineages towards the Indo-Australian Archipelago in the Miocene. A mechanistic model based only on habitat-driven diversification and dispersal yields realistic predictions of current biodiversity patterns for both corals and fishes. As in terrestrial systems, we demonstrate that plate tectonics played a major role in driving tropical marine shallow reef biodiversity dynamics. PMID:27151103

  1. Caribbean tectonics and relative plate motions

    NASA Technical Reports Server (NTRS)

    Burke, K.; Dewey, J. F.; Cooper, C.; Mann, P.; Pindell, J. L.

    1984-01-01

    During the last century, three different ways of interpreting the tectonic evolution of the Gulf of Mexico and the Caribbean have been proposed, taking into account the Bailey Willis School of a permanent pre-Jurassic deep sea basin, the Edward Suess School of a subsided continental terrain, and the Alfred Wegener School of continental separation. The present investigation is concerned with an outline of an interpretation which follows that of Pindell and Dewey (1982). An attempt is made to point out ways in which the advanced hypotheses can be tested. The fit of Africa, North America, and South America is considered along with aspects of relative motion between North and South America since the early Jurasic. Attention is given to a framework for reconstructing Caribbean plate evolution, the evolution of the Caribbean, the plate boundary zones of the northern and southern Caribbean, and the active deformation of the Caribbean plate.

  2. On the dip angle of subducting plates

    NASA Technical Reports Server (NTRS)

    Hsui, Albert T.; Tang, Xiao-Ming; Toksoz, M. Nafi

    1990-01-01

    A new approximate analytic model is developed for the thermal structure of a subducting plate with a finite length. This model provides the capability of easily examining the thermal and mechanical structure of a subducting plate with different lengths and at different angles. Also, the torque balance of a descending plate can be examined, and effects such as the leading edge effect, the adiabatic compression effect, and the phase change effect can be incorporated. A comparison with observed data indicates that short slabs are likely under torque equilibrium at present, while long slabs are probably dominated by their gravitational torques such that their dip angles are transient, moving toward a steeper dip angle similar to that of the Mariana slab.

  3. Drag Measurements of Porous Plate Acoustic Liners

    NASA Technical Reports Server (NTRS)

    Wolter, John D.

    2005-01-01

    This paper presents the results of direct drag measurements on a variety of porous plate acoustic liners. The existing literature describes numerous studies of drag on porous walls with injection or suction, but relatively few of drag on porous plates with neither injection nor suction. Furthermore, the porosity of the porous plate in existing studies is much lower than typically used in acoustic liners. In the present work, the acoustic liners consisted of a perforated face sheet covering a bulk acoustic absorber material. Factors that were varied in the experiment were hole diameter, hole pattern, face sheet thickness, bulk material type, and size of the gap (if any) between the face sheet and the absorber material.

  4. Aerodynamic drag reduction by vertical splitter plates

    NASA Astrophysics Data System (ADS)

    Gilliéron, Patrick; Kourta, Azeddine

    2010-01-01

    The capacity of vertical splitter plates placed at the front or the rear of a simplified car geometry to reduce drag, with and without skew angle, is investigated for Reynolds numbers between 1.0 × 106 and 1.6 × 106. The geometry used is a simplified geometry to represent estate-type vehicles, for the rear section, and MPV-type vehicle. Drag reductions of nearly 28% were obtained for a zero skew angle with splitter plates placed at the front of models of MPV or utility vehicles. The results demonstrate the advantage of adapting the position and orientation of the splitter plates in the presence of a lateral wind. All these results confirm the advantage of this type of solution, and suggest that this expertise should be used in the automotive field to reduce consumption and improve dynamic stability of road vehicles.

  5. Hydrogen Embrittlement of Pulse-Plated Nickel

    NASA Astrophysics Data System (ADS)

    Reese, Eggert D.; Von Bestenbostel, Wolfgang; Sebald, Torsten; Paronis, Georgios; Vanelli, Diego; Müller, Yves

    2014-08-01

    The objective of the European-funded project MultiHy (Multiscale modeling of hydrogen embrittlement in crystalline materials) is the development of multiscale models for hydrogen transport in complex microstructures. The validation and application of the models will be carried out by investigating the role of the microstructure in industrial problems involving hydrogen embrittlement (HE) of advanced materials. Pulse-plated nickel (PP-Ni) material, as used in various industrial applications, has shown a susceptibility to HE that may cause premature failure of a structure. Due to the nature of the pulse-plating process, H is incorporated into the microstructure of the material. This H may lead to crack initiation when combined with localized stress concentrations due to subsequent manufacturing steps, e.g., welding. This article provides an overview of experimental studies aimed at evaluating the influence of the microstructure on the susceptibility of PP-Ni to HE and, ultimately, at improving the plating process.

  6. Impact resistance of composite laminated sandwich plates

    NASA Astrophysics Data System (ADS)

    Kim, Chun-Gon; Jun, Eui-Jin

    1992-01-01

    Investigated are the effects of face layup sequence and core density of a sandwich plate on the impact delamination area of the laminated facesheet. The sandwich plate is made of graphite/epoxy faces and Nomex honeycomb core. The size and shape of delamination due to impact at each interply location have been measured by the room temperature deply technique. The shape of the interply delamination under impact is, in general, found to be two-lobed. The shape exhibits very peculiar regularity under various experimental conditions. The quantitative measurement of delamination size has shown that the face layup with small relative orientation between adjacent plies and high density core are desirable in sandwich plates to reduce the impact delamination.

  7. Deformation and instability of underthrusting lithospheric plates

    NASA Technical Reports Server (NTRS)

    Liu, H.

    1972-01-01

    Models of the underthrusting lithosphere are constructed for the calculation of displacement and deflection. First, a mathematical theory is developed that rigorously demonstrates the elastic instability in the decending lithosphere. The theory states that lithospheric thrust beneath island arcs becomes unstable and suffers deflection as the compression increases. Thus, in the neighborhood of the edges where the lithospheric plate plunges into the asthenosphere and mesosphere its shape will be contorted. Next, the lateral displacement is calculated, and it is shown that, before contortion, the plate will thicken and contract at different positions with the variation in thickness following a parabolic profile. Finally, the depth distribution of the intermediate and deep focus earthquakes is explained in terms of plate buckling and contortion.

  8. Plate tectonics drive tropical reef biodiversity dynamics

    NASA Astrophysics Data System (ADS)

    Leprieur, Fabien; Descombes, Patrice; Gaboriau, Théo; Cowman, Peter F.; Parravicini, Valeriano; Kulbicki, Michel; Melián, Carlos J.; de Santana, Charles N.; Heine, Christian; Mouillot, David; Bellwood, David R.; Pellissier, Loïc

    2016-05-01

    The Cretaceous breakup of Gondwana strongly modified the global distribution of shallow tropical seas reshaping the geographic configuration of marine basins. However, the links between tropical reef availability, plate tectonic processes and marine biodiversity distribution patterns are still unknown. Here, we show that a spatial diversification model constrained by absolute plate motions for the past 140 million years predicts the emergence and movement of diversity hotspots on tropical reefs. The spatial dynamics of tropical reefs explains marine fauna diversification in the Tethyan Ocean during the Cretaceous and early Cenozoic, and identifies an eastward movement of ancestral marine lineages towards the Indo-Australian Archipelago in the Miocene. A mechanistic model based only on habitat-driven diversification and dispersal yields realistic predictions of current biodiversity patterns for both corals and fishes. As in terrestrial systems, we demonstrate that plate tectonics played a major role in driving tropical marine shallow reef biodiversity dynamics.

  9. Noncyanide cadmium plating baths. Final report

    SciTech Connect

    Pearlstein, F.; Agarwala, V.S.

    1991-10-04

    One approach to minimizing toxic wastes is to eliminate the use of cyanide plating baths. Non-cyanide zinc plating baths have been successfully developed and have found widespread use. An investigation was conducted in an attempt to accomplish similar results with cadmium plating baths. The focus of this study was on additives to a near neutral cadmium bath, free of complexing agents. A Hull cell was used to enable visualization of deposits over a broad range of cathode current densities. Experimental design (Taguchi Method) was used to optimize bath parameters and constituent concentrations. Bath parameters have been developed which indicate promise for producing dense deposits with good covering power, and relatively low tendency for hydrogen embrittlement.

  10. Retardation Measurements of Infrared PVA Wave plate

    NASA Astrophysics Data System (ADS)

    Sun, Y.; Z, H.; W, D.; D, Y.; Z, Z.; S, J.

    The wave plate made of Polyvinyl Alcohol PVA plastic film has several advantages such as its lower cost and insensitivity to temperature and incidence angle so it has been used in the Solar Multi-Channel Telescope SMCT in China But the important parameter retardations of PVA wave plates in the near infrared wavelength have never been provided In this paper a convenient and high precise instrument to get the retardations of discrete wavelengths or a continuous function of wavelength in near infrared is developed In this method the retardations of wave plates have been determined through calculating the maximum and minimum of light intensity The instrument error has been shown Additionally we can get the continuous direction of wavelength retardations in the ultraviolet visible or infrared spectral in another way

  11. Plate motions: Simpler than they look

    NASA Astrophysics Data System (ADS)

    Sambridge, M.; Iaffaldano, G.; Bodin, T.

    2012-12-01

    Plate motions shape Earth's surface through time. These kinematics are of paramount importance to make inferences on sea-level change, mantle/lithosphere interactions and dynamic topography among others. Over the last few decades much effort has gone into plate motion reconstructions at finer temporal resolution from ocean-floor finite-rotations. However, measurements feature substantial noise arising mainly from the challenge of identifying precisely magnetic lineations of the ocean-floor, as well as from uncertainties in geomagnetic reversal timescales. It is therefore standard practise to smooth reconstructions typically by averaging over 2 to 5 Myr-long intervals. But this comes at the price of i) downgrading the native resolution of costly measurements and ii) having to choose one among many smoothing methods that do not yield a unique result. At the native resolution of reconstructions, however, the scenario arising is puzzling, as plate motions vary erratically and significantly over short periods of less than 1 Myr. This equally undermines our ability to make geodynamic inferences, because the rates at which forces need to be built upon plates to explain these kinematics far exceed the most optimistic estimates based, for instance, on the temporal evolution of lithospheric slabs into Earth's mantle. Here we focus on the longest and most temporally-resolved records of ocean-floor spreading ever produced, across mid-oceanic ridges in the Atlantic, Indian and South Pacific Oceans. We show that the largest kinematic changes across these ridges relate to data-noise, and are of apparent nature. We overcome this limitation employing a trans-dimensional hierarchical Bayesian framework, which drastically reduces noise without loss of temporal resolution. Changes in the temporal trends of plate motions occur on timescales no shorter than a few million years, yielding simpler kinematic patterns and more plausible dynamics. This has important implications for the

  12. Tomography, the geoid and plate motions

    SciTech Connect

    Gable, C.W.; O'connell, R.J. )

    1991-01-01

    The dynamics of the earth's mantle and its relationship to mantle structure as revealed by seismic tomography, the geoid, and plate motions are discussed in a critical review of U.S. research from the period 1987-1990. Sections are devoted to plates and mantle convection; seismic anomalies, flow, and the geoid; subducted slabs and the 670-km discontinuity; the physical properties of the mantle; plumes; and computational and experimental modeling efforts. Also included is a comprehensive bibliography for the period. 248 refs.

  13. Seismology: tectonic strain in plate interiors?

    PubMed

    Calais, E; Mattioli, G; DeMets, C; Nocquet, J-M; Stein, S; Newman, A; Rydelek, P

    2005-12-15

    It is not fully understood how or why the inner areas of tectonic plates deform, leading to large, although infrequent, earthquakes. Smalley et al. offer a potential breakthrough by suggesting that surface deformation in the central United States accumulates at rates comparable to those across plate boundaries. However, we find no statistically significant deformation in three independent analyses of the data set used by Smalley et al., and conclude therefore that only the upper bounds of magnitude and repeat time for large earthquakes can be inferred at present. PMID:16355163

  14. Relationship between plume and plate tectonics

    NASA Astrophysics Data System (ADS)

    Puchkov, V. N.

    2016-07-01

    The relationship between plate- and plume-tectonics is considered in view of the growth and breakdown of supercontinents, active rifting, the formation of passive volcanic-type continental margins, and the origin of time-progressive volcanic chains on oceanic and continental plates. The mantle wind phenomenon is described, as well as its effect on plume morphology and anisotropy of the ambient mantle. The interaction of plumes and mid-ocean ridges is discussed. The principles and problems of plume activity analysis in subduction- and collision-related foldbelts are considered and illustrated with examples.

  15. Imaging plates calibration to X-rays

    NASA Astrophysics Data System (ADS)

    Curcio, A.; Andreoli, P.; Cipriani, M.; Claps, G.; Consoli, F.; Cristofari, G.; De Angelis, R.; Giulietti, D.; Ingenito, F.; Pacella, D.

    2016-05-01

    The growing interest for the Imaging Plates, due to their high sensitivity range and versatility, has induced, in the last years, to detailed characterizations of their response function in different energy ranges and kind of radiation/particles. A calibration of the Imaging Plates BAS-MS, BAS-SR, BAS-TR has been performed at the ENEA-Frascati labs by exploiting the X-ray fluorescence of different targets (Ca, Cu, Pb, Mo, I, Ta) and the radioactivity of a BaCs source, in order to cover the X-ray range between few keV to 80 keV.

  16. Cascade impactor and jet plate for same

    DOEpatents

    Dahlin, Robert S.; Farthing, William E.; Landham Jr., Edward C.

    2004-02-03

    A sampling system and method for sampling particulate matter from a high-temperature, high-pressure gas stream. A cyclone sampler for use at high temperatures and pressures, and having threadless sacrificial connectors is disclosed. Also disclosed is an improved cascade impactor including jet plates with integral spacers, and alignment features provided for aligning the jet plates with their associated collection substrates. An activated bauxite alkali collector is disclosed, and includes an alumina liner. The sampling system can be operated remotely or locally, and can be permanently installed or configured as a portable system.

  17. Ponderomotive phase plate for transmission electron microscopes

    DOEpatents

    Reed, Bryan W.

    2012-07-10

    A ponderomotive phase plate system and method for controllably producing highly tunable phase contrast transfer functions in a transmission electron microscope (TEM) for high resolution and biological phase contrast imaging. The system and method includes a laser source and a beam transport system to produce a focused laser crossover as a phase plate, so that a ponderomotive potential of the focused laser crossover produces a scattering-angle-dependent phase shift in the electrons of the post-sample electron beam corresponding to a desired phase contrast transfer function.

  18. PC-based car license plate reader

    NASA Astrophysics Data System (ADS)

    Hwang, Chung-Mu; Shu, Shyh-Yeong; Chen, Wen-Yu; Chen, Yie-Wern; Wen, Kuang-Pu

    1992-11-01

    A car license plate reader (CLPR) using fuzzy inference and neural network algorithm has been developed in Industrial Technology Research Institute (ITRI) and installed in highway toll stations to identify stolen cars. It takes an average of 0.7 seconds to recognize a car license plate by using a PC with 80486-50 CPU. The recognition rate of the system is about 97%. The techniques of CLPR include vehicle sensing, image grab control, optic pre- processing, lighting, and optic character recognition (OCR). The CLPR can be used in vehicle flow statistics, the checking of stolen vehicles, automatic charging systems in parking lots or garage management, and so on.

  19. Spirit Beside 'Home Plate,' Sol 1809

    NASA Technical Reports Server (NTRS)

    2009-01-01

    NASA Mars Exploration Rover Spirit used its navigation camera to take the images assembled into this 120-degree view southward after a short drive during the 1,809th Martian day, or sol, of Spirit's mission on the surface of Mars (February 3, 2009).

    Spirit had driven about 2.6 meters (8.5 feet) that sol, continuing a clockwise route around a low plateau called 'Home Plate.' In this image, the rocks visible above the rovers' solar panels are on the slope at the northern edge of Home Plate.

    This view is presented as a cylindrical projection with geometric seam correction.

  20. Plating of open pediatric tibia fractures.

    PubMed

    Head, James; Lewis, T R; Puffinbarger, William; Garbrecht, Erika

    2014-07-01

    This study is a single center retrospective chart and radiographic review of patients with open tibia fractures under the age of 16 years of age over past 10 years. The purpose of this study is to investigate the treatment of open pediatric tibia fractures with plating in regards to time to ambulation, time to union, and deformity in comparison to other treatment options. We found that plating open pediatric tibia fractures is a safe treatment option that can lead to excellent results with low risk of complications. PMID:25223152