Science.gov

Sample records for 96-well plate system

  1. Electrothermal micromixing in 96 well plate

    NASA Astrophysics Data System (ADS)

    Kauffmann, Paul; Loire, Sophie; Mezic, Igor

    2011-11-01

    Diagnostic and pharmacology processes could be greatly accelerated by appropriate mixing. Here electrothermal flows are explored to provide mixing of conductive physiological solutions (=1.6 S/m) in a 96 well plate. Three interdigitated electrodes provide an electric field (< 15Vpp, 1MHz) beneath each well. Polarization and conduction phenomenon of the fluid in a well will be first modeled numerically and compared to an electrical circuit model. Due to high conductivity and permittivity of the fluid, the impedance of the array of filled wells collapse dramatically (96 wells: R = 1Ohm, C=250nF). The power supply challenges accordingly raised by arrays of electrothermal micromixers will be then analyzed. The efficiency of different methods of mixing in those wells will be also compared: the addition of low frequency signal leading to AC electro-osmotic perturbations, a blinking vortices method. The experimental results will be compared to simulations.

  2. Scalable 96-well Plate Based iPSC Culture and Production Using a Robotic Liquid Handling System.

    PubMed

    Conway, Michael K; Gerger, Michael J; Balay, Erin E; O'Connell, Rachel; Hanson, Seth; Daily, Neil J; Wakatsuki, Tetsuro

    2015-01-01

    Continued advancement in pluripotent stem cell culture is closing the gap between bench and bedside for using these cells in regenerative medicine, drug discovery and safety testing. In order to produce stem cell derived biopharmaceutics and cells for tissue engineering and transplantation, a cost-effective cell-manufacturing technology is essential. Maintenance of pluripotency and stable performance of cells in downstream applications (e.g., cell differentiation) over time is paramount to large scale cell production. Yet that can be difficult to achieve especially if cells are cultured manually where the operator can introduce significant variability as well as be prohibitively expensive to scale-up. To enable high-throughput, large-scale stem cell production and remove operator influence novel stem cell culture protocols using a bench-top multi-channel liquid handling robot were developed that require minimal technician involvement or experience. With these protocols human induced pluripotent stem cells (iPSCs) were cultured in feeder-free conditions directly from a frozen stock and maintained in 96-well plates. Depending on cell line and desired scale-up rate, the operator can easily determine when to passage based on a series of images showing the optimal colony densities for splitting. Then the necessary reagents are prepared to perform a colony split to new plates without a centrifugation step. After 20 passages (~3 months), two iPSC lines maintained stable karyotypes, expressed stem cell markers, and differentiated into cardiomyocytes with high efficiency. The system can perform subsequent high-throughput screening of new differentiation protocols or genetic manipulation designed for 96-well plates. This technology will reduce the labor and technical burden to produce large numbers of identical stem cells for a myriad of applications. PMID:26068617

  3. Parabolic growth patterns in 96-well plate cell growth experiments.

    PubMed

    Faessel, H M; Levasseur, L M; Slocum, H K; Greco, W R

    1999-05-01

    In preparing for the routine use of the ubiquitous in vitro cell growth inhibition assay for the study of anticancer agents, we characterized the statistical properties of the assay and found some surprising results. Parabolic well-to-well cell growth patterns were discovered, which could profoundly affect the results of routine growth inhibition studies of anticancer and other agents. Four human ovarian cell lines, A2780/WT, A2780/DX5, A2780/DX5B, and A121, and one human ileocecal adenocarcinoma cell line, HCT-8, were seeded into plastic 96-well plates with a 12-channel pipette, without drugs, and grown from 1-5 d. The wells were washed with a plate washer, cells stained with sulforhodamine B (SRB), and dye absorbance measured with a plate reader. Variance models were fit to the data from replicates to determine the nature of the heteroscedastic error structure. Exponential growth models were fit to data to estimate doubling times for each cell line. Polynomial models were fit to data from 10-plate stacks of 96-well plates to explore nonuniformity of cell growth in wells in different regions of the stacks. Each separate step in the assay was examined for precision, patterns, and underlying causes of variation. Differential evaporation of water from wells is likely a major, but not exclusive, contributor to the systematic well-to-well cell growth patterns. Because the fundamental underlying causes of the parabolic growth patterns were not conclusively found, a randomization step for the growth assay was developed.

  4. 96-well microtiter plates for biofouling simulation in biomedical settings.

    PubMed

    Gomes, L C; Moreira, J M R; Teodósio, J S; Araújo, J D P; Miranda, J M; Simões, M; Melo, L F; Mergulhão, F J

    2014-01-01

    Microtiter plates with 96 wells are routinely used in biofilm research mainly because they enable high-throughput assays. These platforms are used in a variety of conditions ranging from static to dynamic operation using different shaking frequencies and orbital diameters. The main goals of this work were to assess the influence of nutrient concentration and flow conditions on biofilm formation by Escherichia coli in microtiter plates and to define the operational conditions to be used in order to simulate relevant biomedical scenarios. Assays were performed in static mode and in incubators with distinct orbital diameters using different concentrations of glucose, peptone and yeast extract. Computational fluid dynamics (CFD) was used to simulate the flow inside the wells for shaking frequencies ranging from 50 to 200 rpm and orbital diameters from 25 to 100 mm. Higher glucose concentrations enhanced adhesion of E. coli in the first 24 h, but variation in peptone and yeast extract concentration had no significant impact on biofilm formation. Numerical simulations indicate that 96-well microtiter plates can be used to simulate a variety of biomedical scenarios if the operating conditions are carefully set.

  5. HIGHLY SENSITIVE ASSAY FOR ANTICHOLINESTERASE COMPOUNDS USING 96 WELL PLATE FORMAT

    EPA Science Inventory

    The rapid and sensitive detection of organophosphate insecticides using a 96 well plate format is reported. Several features of this assay make it attractive for development as a laboratory-based or field screening assay. Acetylcholinesterase (AChE) was stabilized in a gelati...

  6. Toward Microbioreactor Arrays: A Slow-Responding Oxygen Sensor for Monitoring of Microbial Cultures in Standard 96-Well Plates.

    PubMed

    Glauche, Florian; John, Gernot T; Arain, Sarina; Knepper, Andreas; Neubauer, Antje; Goelling, Detlef; Lang, Christine; Violet, Norman; King, Rudibert; Neubauer, Peter

    2015-08-01

    In this study, a slow-responding chemo-optical sensor for dissolved oxygen (DO) integrated into a 96-well plate was developed. The slow response time ensures that the measured oxygen value does not change much during plate transport to the microplate reader. The sensor therefore permits at-line DO measurement of microbial cultures. Moreover, it eliminates the necessity of individual optical measurement systems for each culture plate, as many plates can be measured successively. Combined with the 96-well format, this increases the experimental throughput enormously. The novel sensor plate (Slow OxoPlate) consists of fluorophores suspended in a polymer matrix that were placed into u-bottom 96-well plates. Response time was measured using sodium sulfite, and a t90 value of 9.7 min was recorded. For application, DO values were then measured in Escherichia coli and Saccharomyces cerevisiae cultures grown under fed-batch-like conditions. Depending on the DO sensor's response time, different information on the oxygenation state of the culture plate was obtained: a fast sensor variant detects disturbance through sampling, whereas the slow sensor indicates oxygen limitation during incubation. A combination of the commercially available OxoPlate and the Slow OxoPlate enables operators of screening facilities to validate their cultivation procedures with regard to oxygen availability. PMID:25720599

  7. Toward Microbioreactor Arrays: A Slow-Responding Oxygen Sensor for Monitoring of Microbial Cultures in Standard 96-Well Plates.

    PubMed

    Glauche, Florian; John, Gernot T; Arain, Sarina; Knepper, Andreas; Neubauer, Antje; Goelling, Detlef; Lang, Christine; Violet, Norman; King, Rudibert; Neubauer, Peter

    2015-08-01

    In this study, a slow-responding chemo-optical sensor for dissolved oxygen (DO) integrated into a 96-well plate was developed. The slow response time ensures that the measured oxygen value does not change much during plate transport to the microplate reader. The sensor therefore permits at-line DO measurement of microbial cultures. Moreover, it eliminates the necessity of individual optical measurement systems for each culture plate, as many plates can be measured successively. Combined with the 96-well format, this increases the experimental throughput enormously. The novel sensor plate (Slow OxoPlate) consists of fluorophores suspended in a polymer matrix that were placed into u-bottom 96-well plates. Response time was measured using sodium sulfite, and a t90 value of 9.7 min was recorded. For application, DO values were then measured in Escherichia coli and Saccharomyces cerevisiae cultures grown under fed-batch-like conditions. Depending on the DO sensor's response time, different information on the oxygenation state of the culture plate was obtained: a fast sensor variant detects disturbance through sampling, whereas the slow sensor indicates oxygen limitation during incubation. A combination of the commercially available OxoPlate and the Slow OxoPlate enables operators of screening facilities to validate their cultivation procedures with regard to oxygen availability.

  8. Biofilm Localization in the Vertical Wall of Shaking 96-Well Plates

    PubMed Central

    Gomes, Luciana C.; Moreira, Joana M. R.; Simões, Manuel; Melo, Luís F.; Mergulhão, Filipe J.

    2014-01-01

    Microtiter plates with 96 wells are being increasingly used for biofilm studies due to their high throughput, low cost, easy handling, and easy application of several analytical methods to evaluate different biofilm parameters. These methods provide bulk information about the biofilm formed in each well but lack in detail, namely, regarding the spatial location of the biofilms. This location can be obtained by microscopy observation using optical and electron microscopes, but these techniques have lower throughput and higher cost and are subjected to equipment availability. This work describes a differential crystal violet (CV) staining method that enabled the determination of the spatial location of Escherichia coli biofilms formed in the vertical wall of shaking 96-well plates. It was shown that the biofilms were unevenly distributed on the wall with denser cell accumulation near the air-liquid interface. The results were corroborated by scanning electron microscopy and a correlation was found between biofilm accumulation and the wall shear strain rates determined by computational fluid dynamics. The developed method is quicker and less expensive and has a higher throughput than the existing methods available for spatial location of biofilms in microtiter plates. PMID:24834360

  9. Quantification of lymphocytic choriomeningitis virus with an immunological focus assay in 24- or 96-well plates.

    PubMed

    Battegay, M; Cooper, S; Althage, A; Bänziger, J; Hengartner, H; Zinkernagel, R M

    1991-06-01

    Titers of lymphocytic choriomeningitis virus (LCMV) were determined on adherent fibroblast cell lines in 24- or 96-well plates. After absorption of virus by cells and 48 h incubation under a methylcellulose overlay, cell monolayers were fixed with 4% formaldehyde in phosphate-buffered saline, permeabilized by incubation in 0.5% Triton X-100 in balanced salt solution and then stained with a monoclonal rat anti-LCMV and a peroxidase-labeled second stage antibody. The sensitivity of the assay is within a factor of 2-4 of conventional plaquing methods. The method also detects poorly or non-plaquing LCMV isolates, and therefore drastically reduces the need for titration of LCMV in mice. The method is quicker (2-3 days), as compared to conventional methods (4-6 days) and less expensive in terms of work and materials.

  10. Fluorinert, an oxygen carrier, improves cell culture performance in deep square 96-well plates by facilitating oxygen transfer.

    PubMed

    Meyer, Aaron; Condon, Russell G G; Keil, Gregory; Jhaveri, Nikita; Liu, Zhong; Tsao, Yung-Shyeng

    2012-01-01

    In bioprocess development, the 96-well plate format has been widely used for high-throughput screening of production cell line or culture conditions. However, suspension cell cultures in conventional 96-well plates often fail to reach high cell density under normal agitation presumably due to constraints in oxygen transfer. Although more vigorous agitation can improve gas transfer in 96-well plate format, it often requires specialized instruments. In this report, we employed Fluorinert, a biologically inert perfluorocarbon, to improve oxygen transfer in 96-well plate and to enable the growth of a Chinese Hamster Ovary cell line expressing a recombinant monoclonal antibody. When different amounts of Fluorinert were added to the cell culture medium, a dose-dependent improvement in cell growth was observed in both conventional and deep square 96-well plates. When sufficient Fluorinert was present in the culture, the cell growth rate, the peak cell density, and recombinant protein production levels achieved in deep square 96-wells were comparable to cultures in ventilated shake flasks. Although Fluorinert is known to dissolve gases such as oxygen and CO(2), it does not dissolve nor extract medium components, such as glucose, lactate, or amino acids. We conclude that mixing Fluorinert with culture media is a suitable model for miniaturization of cell line development and process optimization. Proper cell growth and cellular productivity can be obtained with a standard shaker without the need for any additional aeration or vigorous agitation. PMID:21954223

  11. A solid-phase Bcr-Abl kinase assay in 96-well hydrogel plates.

    PubMed

    Wu, Ding; Mand, Michael R; Veach, Darren R; Parker, Laurie L; Clarkson, Bayard; Kron, Stephen J

    2008-04-01

    Regulated phosphorylation by protein tyrosine kinases (PTKs), such as c-Abl, is critical to cellular homeostasis. In turn, once deregulated as in the chronic myeloid leukemia (CML) fusion protein Bcr-Abl, PTKs can promote cancer onset and progression. The dramatic success of the Bcr-Abl inhibitor imatinib as therapy for CML has inspired interest in other PTKs as targets for cancer drug discovery. Here we report a novel PTK activity and inhibition screening method using hydrogel-immobilized peptide substrates. Using acrylate crosslinkers, we tether peptides via terminal cysteines to thiol-presenting hydrogels in 96-well plates. These surfaces display low background and high reproducibility, allowing semiquantitative detection of peptide phosphorylation by recombinant c-Abl or by Bcr-Abl activity in cell extracts using traditional anti-phosphotyrosine immunodetection and chemifluorescence. The capabilities of this assay are demonstrated by performing model screens for inhibition with several commercially available PTK inhibitors and a collection of pyridopyrimidine Src/Abl dual inhibitors. This assay provides a practical method to measure the activity of a single kinase present in a whole cell lysate with high sensitivity and specificity as a valuable means for efficient small molecule screening.

  12. Macroscale versus microscale methods for physiological analysis of biofilms formed in 96-well microtiter plates.

    PubMed

    Gomes, L C; Moreira, J M R; Miranda, J M; Simões, M; Melo, L F; Mergulhão, F J

    2013-12-01

    Microtiter plates with 96 wells have become one of the preferred platforms for biofilm studies mainly because they enable high-throughput assays. In this work, macroscale and microscale methods were used to study the impact of hydrodynamic conditions on the physiology and location of Escherichia coli JM109(DE3) biofilms formed in microtiter plates. Biofilms were formed in shaking and static conditions, and two macroscale parameters were assayed: the total amount of biofilm was measured by the crystal violet assay and the metabolic activity was determined by the resazurin assay. From the macroscale point of view, there were no statistically significant differences between the biofilms formed in static and shaking conditions. However, at a microscale level, the differences between both conditions were revealed using scanning electron microscopy (SEM). It was observed that biofilm morphology and spatial distribution along the wall were different in these conditions. Simulation of the hydrodynamic conditions inside the wells at a microscale was performed by computational fluid dynamics (CFD). These simulations showed that the shear strain rate was unevenly distributed on the walls during shaking conditions and that regions of higher shear strain rate were obtained closer to the air/liquid interface. Additionally, it was shown that wall regions subjected to higher shear strain rates were associated with the formation of biofilms containing cells of smaller size. Conversely, regions with lower shear strain rate were prone to have a more uniform spatial distribution of adhered cells of larger size. The results presented on this work highlight the wealth of information that may be gathered by complementing macroscale approaches with a microscale analysis of the experiments. PMID:24140575

  13. Ice-Cap: a method for growing Arabidopsis and tomato plants in 96-well plates for high-throughput genotyping.

    PubMed

    Su, Shih-Heng; Clark, Katie A; Gibbs, Nicole M; Bush, Susan M; Krysan, Patrick J

    2011-11-09

    It is becoming common for plant scientists to develop projects that require the genotyping of large numbers of plants. The first step in any genotyping project is to collect a tissue sample from each individual plant. The traditional approach to this task is to sample plants one-at-a-time. If one wishes to genotype hundreds or thousands of individuals, however, using this strategy results in a significant bottleneck in the genotyping pipeline. The Ice-Cap method that we describe here provides a high-throughput solution to this challenge by allowing one scientist to collect tissue from several thousand seedlings in a single day (1,2). This level of throughput is made possible by the fact that tissue is harvested from plants 96-at-a-time, rather than one-at-a-time. The Ice-Cap method provides an integrated platform for performing seedling growth, tissue harvest, and DNA extraction. The basis for Ice-Cap is the growth of seedlings in a stacked pair of 96-well plates. The wells of the upper plate contain plugs of agar growth media on which individual seedlings germinate. The roots grow down through the agar media, exit the upper plate through a hole, and pass into a lower plate containing water. To harvest tissue for DNA extraction, the water in the lower plate containing root tissue is rapidly frozen while the seedlings in the upper plate remain at room temperature. The upper plate is then peeled away from the lower plate, yielding one plate with 96 root tissue samples frozen in ice and one plate with 96 viable seedlings. The technique is named "Ice-Cap" because it uses ice to capture the root tissue. The 96-well plate containing the seedlings can then wrapped in foil and transferred to low temperature. This process suspends further growth of the seedlings, but does not affect their viability. Once genotype analysis has been completed, seedlings with the desired genotype can be transferred from the 96-well plate to soil for further propagation. We have demonstrated

  14. A 96-well screen filter plate for high-throughput biological sample preparation and LC-MS/MS analysis.

    PubMed

    Peng, Sean X; Cousineau, Martin; Juzwin, Stephen J; Ritchie, David M

    2006-01-01

    A novel 96-well screen filter plate (patent pending) has been invented to eliminate a time-consuming and labor-intensive step in preparation of in vivo study samples--to remove blood or plasma clots. These clots plug the pipet tips during a manual or automated sample-transfer step causing inaccurate pipetting or total pipetting failure. Traditionally, these blood and plasma clots are removed by picking them out manually one by one from each sample tube before any sample transfer can be made. This has significantly slowed the sample preparation process and has become a bottleneck for automated high-throughput sample preparation using robotic liquid handlers. Our novel screen filter plate was developed to solve this problem. The 96-well screen filter plate consists of 96 stainless steel wire-mesh screen tubes connected to the 96 openings of a top plate so that the screen filter plate can be readily inserted into a 96-well sample storage plate. Upon insertion, the blood and plasma clots are excluded from entering the screen tube while clear sample solutions flow freely into it. In this way, sample transfer can be easily completed by either manual or automated pipetting methods. In this report, three structurally diverse compounds were selected to evaluate and validate the use of the screen filter plate. The plasma samples of these compounds were transferred and processed in the presence and absence of the screen filter plate and then analyzed by LC-MS/MS methods. Our results showed a good agreement between the samples prepared with and without the screen filter plate, demonstrating the utility and efficiency of this novel device for preparation of blood and plasma samples. The device is simple, easy to use, and reusable. It can be employed for sample preparation of other biological fluids that contain floating particulates or aggregates. PMID:16383347

  15. MStern Blotting-High Throughput Polyvinylidene Fluoride (PVDF) Membrane-Based Proteomic Sample Preparation for 96-Well Plates.

    PubMed

    Berger, Sebastian T; Ahmed, Saima; Muntel, Jan; Cuevas Polo, Nerea; Bachur, Richard; Kentsis, Alex; Steen, Judith; Steen, Hanno

    2015-10-01

    We describe a 96-well plate compatible membrane-based proteomic sample processing method, which enables the complete processing of 96 samples (or multiples thereof) within a single workday. This method uses a large-pore hydrophobic PVDF membrane that efficiently adsorbs proteins, resulting in fast liquid transfer through the membrane and significantly reduced sample processing times. Low liquid transfer speeds have prevented the useful 96-well plate implementation of FASP as a widely used membrane-based proteomic sample processing method. We validated our approach on whole-cell lysate and urine and cerebrospinal fluid as clinically relevant body fluids. Without compromising peptide and protein identification, our method uses a vacuum manifold and circumvents the need for digest desalting, making our processing method compatible with standard liquid handling robots. In summary, our new method maintains the strengths of FASP and simultaneously overcomes one of the major limitations of FASP without compromising protein identification and quantification. PMID:26223766

  16. Thermodynamic equilibrium solubility measurements in simulated fluids by 96-well plate method in early drug discovery.

    PubMed

    Bharate, Sonali S; Vishwakarma, Ram A

    2015-04-01

    An early prediction of solubility in physiological media (PBS, SGF and SIF) is useful to predict qualitatively bioavailability and absorption of lead candidates. Despite of the availability of multiple solubility estimation methods, none of the reported method involves simplified fixed protocol for diverse set of compounds. Therefore, a simple and medium-throughput solubility estimation protocol is highly desirable during lead optimization stage. The present work introduces a rapid method for assessment of thermodynamic equilibrium solubility of compounds in aqueous media using 96-well microplate. The developed protocol is straightforward to set up and takes advantage of the sensitivity of UV spectroscopy. The compound, in stock solution in methanol, is introduced in microgram quantities into microplate wells followed by drying at an ambient temperature. Microplates were shaken upon addition of test media and the supernatant was analyzed by UV method. A plot of absorbance versus concentration of a sample provides saturation point, which is thermodynamic equilibrium solubility of a sample. The established protocol was validated using a large panel of commercially available drugs and with conventional miniaturized shake flask method (r(2)>0.84). Additionally, the statistically significant QSPR models were established using experimental solubility values of 52 compounds.

  17. IDENTIFICATION OF SALMONELLA-POSITIVE FECAL SAMPLES USING A 96-WELL MICROCULTURE PLATE TECHNIQUE (RX METHOD)

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Conventional Salmonella isolation involves multiple sample transfers to culture media performed by an experienced microbiologist. The Reaction (RX) Plate method, a modification of the RX tube designed by Gailey et al. (2004), consolidates pre-enrichment (buffered peptone water or GN Hajna), enrichm...

  18. IDENTIFICATION OF SALMONELLA-POSITIVE FECAL SAMPLES USING A 96-WELL MICROCULTURE PLATE TECHNIQUE (RX METHOD)

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Conventional Salmonella isolation involves multiple sample transfers to culture media performed by an experienced microbiologist. The modified semi-solid RV and XLT (RX) Plate method, a modification of the RX tube format designed by Gailey et al. (2004), consolidates pre-enrichment (buffered pepton...

  19. Human tear analysis with miniaturized multiplex cytokine assay on “wall-less” 96-well plate

    PubMed Central

    Quah, Joanne; Tong, Louis; Kim, Namyong

    2015-01-01

    Purpose Tears are a particularly limited body fluid and commonly used in the diagnosis of patients who have ocular diseases. A popular method for analysis of ocular inflammation in tears uses Luminex® bead multiplex technology to generate valuable multiple cytokine profile outputs with 25–50 µl tear sample volume. We propose a method for measuring tear cytokines with 5 μl tear sample volume and 80% reduced Luminex reagents compared to previous protocols. Methods Using human tears pooled from 1,000 participants, the DA-Bead-based method running at 5–20 µl volume, using manual pipetting, in conjunction with a magnetic Luminex cytokine (four-plex) panel assay in a 96-well format was performed and validated for tumor necrosis factor (TNF)-α, interferon (IFN)-γ, interleukin (IL)-1β, and IL-6. Results Upon use of the DA-Bead method at the 5 μl volume with cytokine standards, the concentrations of each of the four cytokines were found to be linear over a range of 3.5–4 log pg/ml with an intra-assay coefficient of variation (CV) ≤5%, inter-assay %CV ≤10%, and accuracy within the 70–130% range. Upon use of a 5 µl healthy pooled tear sample, cytokine concentrations were detected with a precision intra-assay %CV ˂ 20% for IL-6, IFN-γ, or TNF-α or 30.37% with IL-1β. The inter-assay %CV with tears was ≤20.84% for all cytokines. Tear volumes run at 5 μl on DA-Bead produced a similar cytokine expression profile at a 1-month interval and were highly correlated with the larger 10 μl–based tear sample volume cytokine profile with R2 = 0.98. Conclusions DA-Bead assay is highly sensitive and reproducible and has a performance profile that is potentially suitable for use in standard clinical scenarios. Considering the use of as little as 5 µl of assay beads and 5 µl sample, this is also likely to reduce the assay cost significantly and ease diagnosis of patients with ocular diseases. PMID:26539027

  20. Development of a fluorimetric multispecies 96-well micro-plate growth test for screening metal toxicity to phytoplankton

    SciTech Connect

    Peterson, H.G.; Ruecker, N.J.; Cantin, I.A.; Nyholm, N.; Dal-Jensen, S.

    1995-12-31

    The rapid and cost-effective screening of industrial waste is an ideal approach to regulations that offer true protection of aquatic habitats. For these tests to be ecologically important protection of large groups of organisms is also essential. This can best be done by testing batteries of species. Photosynthetic organisms compose 99.9% of habitats as well as providing food for higher trophic levels. A test was developed that can accommodate the testing of most phytoplanktonic species irrespective of morphology (unicellular, multicellular, colonial, filamentous). Forty eight to 72 h growth tests were carried out with green algae, diatoms, and cyanobacteria. The algae were incubated with different levels of toxicants in 96-well microplates which were read in a 96-well fluorometric plate reader. Phytoplankton emitting low levels of fluorescence can be incubated with DCMU, which can increase the fluorescent signal 2 to 4 times. The data from the plate reader is transferred to a computer spreadsheet and inhibition levels are automatically calculated. Eleven metal mining wastes from across Canada were tested against this method using the following phytoplanktonic species: Selenastrum, Nannochloris (green algae), Nitzschia (diatom), Microcystis, and Pseudoanabaena (cyanobacteria). These wastes were also screened against Microtox. All wastes were highly toxic to the tested phytoplankton, but only 4 were toxic to Microtox{trademark}.

  1. A Novel 96well-formatted Micro-gap Plate Enabling Drug Response Profiling on Primary Tumour Samples

    NASA Astrophysics Data System (ADS)

    Ma, Wei-Yuan; Hsiung, Lo-Chang; Wang, Chen-Ho; Chiang, Chi-Ling; Lin, Ching-Hung; Huang, Chiun-Sheng; Wo, Andrew M.

    2015-04-01

    Drug-based treatments are the most widely used interventions for cancer management. Personalized drug response profiling remains inherently challenging with low cell count harvested from tumour sample. We present a 96well-formatted microfluidic plate with built-in micro-gap that preserves up to 99.2% of cells during multiple assay/wash operation and only 9,000 cells needed for a single reagent test (i.e. 1,000 cells per test spot x 3 selected concentration x triplication), enabling drug screening and compatibility with conventional automated workstations. Results with MCF7 and MDA-MB-231 cell lines showed that no statistical significance was found in dose-response between the device and conventional 96-well plate control. Primary tumour samples from breast cancer patients tested in the device also showed good IC50 prediction. With drug screening of primary cancer cells must consider a wide range of scenarios, e.g. suspended/attached cell types and rare/abundant cell availability, the device enables high throughput screening even for suspended cells with low cell count since the signature microfluidic cell-trapping feature ensures cell preservation in a multiple solution exchange protocol.

  2. 96-Well Plate Colorimetric Assay for K(sub i) Determination of (plusmn)-2-Benzylsuccinic Acid, an Inhibitor of Carboxypeptidase A

    ERIC Educational Resources Information Center

    Wentland, Mark P.; Raza, Shaan; Yingtong Gao

    2004-01-01

    An appropriate assay to determine the inhibition potency of carboxypeptidase A (CPA) in 96-well format to illustrate how high throughput screening is used in modern drug discovery to identify bioactive molecules is developed. Efforts in developing a colorimetric 96-well plate assay for determination of the K(sub i) for inhibition of CPA by…

  3. Facile preparation of a photoactivatable surface on a 96-well plate: a versatile and multiplex cell migration assay platform.

    PubMed

    Kamimura, Masao; Scheideler, Olivia; Shimizu, Yoshihisa; Yamamoto, Shota; Yamaguchi, Kazuo; Nakanishi, Jun

    2015-06-01

    Cell migration is an essential cellular activity in various physiological and pathological processes, such as wound healing and cancer metastasis. Therefore, in vitro cell migration assays are important not only for fundamental biological studies but also for evaluating potential drugs that control cell migration activity in medical applications. In this regard, robust control over cell migrating microenvironments is critical for reliable and quantitative analysis as cell migration is highly dependent upon the microenvironments. Here, we developed a facile method for making a commercial glass-bottom 96-well plate photoactivatable for cell adhesion, aiming to develop a versatile and multiplex cell migration assay platform. Cationic poly-d-lysine was adsorbed to the anionic glass surface via electrostatic interactions and, subsequently, functionalized with poly(ethylene glycol) (PEG) bearing a photocleavable reactive group. The initial PEGylated surface is non-cell-adhesive. However, upon near-ultraviolet (UV) irradiation, the photorelease of PEG switches the surface from non-biofouling to cell-adhesive. With this platform, we assayed cell migration in the following procedure: (1) create cell-attaching regions of precise geometries by controlled photoirradiation, (2) seed cells to allow them to attach selectively to the irradiated regions, (3) expose UV light to the remaining PEGylated regions to extend the cell-adhesive area, (4) analyse cell migration using microscopy. Surface modification of the glass surface was characterized by ζ-potential and contact angle measurements. The PEGylated surface showed cell-resistivity and became cell-adhesive upon releasing PEG by near-UV irradiation. The method was applied for parallelly evaluating the effect of model drugs on the migration of epithelial MDCK cells in the multiplexed platform. The dose-response relationship for cytochalasin D treatment on cell migration behavior was successfully evaluated with high

  4. A new approach to the application of solid phase extraction disks with LC-MS/MS for the analysis of drugs on a 96-well plate format.

    PubMed

    Cudjoe, Erasmus; Pawliszyn, Janusz

    2009-11-01

    A new 96-well disk solid phase extraction sample preparation technique which does not involve vacuum pumps integrated with liquid chromatographic tandem mass spectrometric (LC-MS/MS) was developed for high throughput determination of benzodiazepines (nordiazepam, diazepam, lorazepam and oxazepam). In addition, the method completely allows the re-use of the SPE disk membranes for subsequent analyses after re-conditioning. The method utilizes a robotic autosampler for parallel extractions in a 96-well plate format. Results have been presented for independent extractions from three matrices; phosphate buffer solution, urine, and plasma. Factors affecting data reproducibility, extraction kinetics, sample throughput, and reliability of the system were investigated and optimized. A total time required per sample was 0.94 min using 96-well format. Method reproducibility was < or =9% relative standard deviation for all three matrices. Limits of detection and quantitation recorded were respectively in the range 0.02-0.15 and 0.2-2.0 ng/mL with linearity ranging from 0.2 to 500 ng/mL for all matrices.

  5. Quantum dot immunoassays in renewable surface column and 96-well plate formats for the fluorescence detection of Botulinum neurotoxin using high-affinity antibodies

    SciTech Connect

    Warner, Marvin G.; Grate, Jay W.; Tyler, Abby J.; Ozanich, Richard M.; Miller, Keith D.; Lou, Jianlong; Marks, James D.; Bruckner-Lea, Cindy J.

    2009-09-01

    A fluorescence sandwich immunoassay using high affinity antibodies and quantum dot (QD) reporters has been developed for detection of botulinum toxin serotype A (BoNT/A). For the development of the assay, a nontoxic recombinant fragment of the holotoxin (BoNT/A-HC-fragment) has been used as a structurally valid simulant for the full toxin molecule. The antibodies used, AR4 and RAZ1, bind to nonoverlapping epitopes present on both the full toxin and on the recombinant fragment. In one format, the immunoassay is carried out in a 96-well plate with detection in a standard plate reader. Detection down to 31 pM of the BoNT/Hc-fragment was demonstrated with a total incubation time of 3 hours, using AR4 as the capture antibody and QD-coupled RAZ1 as the reporter. In a second format, the AR4 capture antibody was coupled to Sepharose beads, and the immunochemical reactions were carried out in microcentrifuge tubes with an incubation time of 1 hour. These beads were subsequently captured and concentrated in a rotating rod “renewable surface” flow cell as part of a sequential injection fluidic system. This flow cell was equipped with a fiber optic system for fluorescence measurements. In PBS buffer solution matrix, the BoNT/A-HC-fragment was detected to concentrations as low as 5 pM using the fluidic measurement approach.

  6. Microwave-Accelerated Metal-Enhanced Fluorescence (MAMEF) with silver colloids in 96-well plates: Application to ultra fast and sensitive immunoassays, High Throughput Screening and drug discovery.

    PubMed

    Aslan, Kadir; Holley, Patrick; Geddes, Chris D

    2006-05-30

    Fluorescence detection is the basis of most assays used in drug discovery and High Throughput Screening (HTS) today. In all of these assays, assay rapidity and sensitivity is a primary concern, the sensitivity determined by both the quantum yield of the fluorophores and efficiency of the detection system, while rapidity is determined by the physical and biophysical parameters of temperature, concentration, assay bioaffinity, etc. In this paper we describe a platform technology that promises to fundamentally address these two physical constraints of sensitivity and rapidity. By combining the use of Metal-Enhanced Fluorescence (MEF), a near-field effect that can significantly enhance fluorescence signatures, with low power microwave heating, we can significantly increase the sensitivity of surface assays as well as >95% kinetically complete the assay within a few seconds. In addition, the metallic nanostructures used to facilitate MEF appear to be preferentially heated as compared to the surface assay fluid, advantageously localizing the MEF and heating around the nanostructures. To demonstrate proof of principle, a 96-well plate has been functionalized with silver nanostructures, and a model protein avidin-biotin assay studied. In our findings, a greater than 5-fold fluorescence enhancement coupled with a approximately 90-fold increase in assay kinetics was observed, but with no assay washing steps needed due to the silver-enhanced evanescent field mode of excitation. These findings promise to strongly facilitate high throughput fluorescence-based processes, such as in biology, drug discovery and general compound screening.

  7. Immobilization of saccharides and peptides on 96-well microtiter plates coated with methyl vinyl ether-maleic anhydride copolymer.

    PubMed

    Satoh, A; Kojima, K; Koyama, T; Ogawa, H; Matsumoto, I

    1998-06-15

    We have previously reported a method to immobilize protein ligands on microtiter plates coated with methyl vinyl ether-maleic anhydride copolymer (MMAC) [Isosaki, K., et al. (1992) J. Chromatogr. 597, 123-128]. In this study, we improved the MMAC method to efficiently immobilize not only small ligands such as peptides and oligosaccharides, which could not be efficiently immobilized previously, but also heparin via its reducing end. Amino and hydrazino groups were introduced to MMAC-coated microtiter plate wells by coupling to acid anhydride groups of MMAC with 1,6-hexamethylenediamine and adipic acid dihydrazide, respectively. The amino groups introduced were allowed to react with peptides by use of divalent cross-linkers. Hydrazino groups were allowed to react with formyl groups of saccharides by reductive amination. Peptides and oligosaccharides were immobilized in a dose-dependent manner by these methods. In the case of the angiotensin peptide thus immobilized, the detection limit by monoclonal antibodies was as low as 0.1-1 fmol peptide per well. Application of 20-200 nmol oligosaccharides to the well was sufficient to immobilize and subsequently detect lectins. Furthermore, heparin immobilized on the hydrazinocoated wells was successfully used for the binding assay of annexin IV. PMID:9648659

  8. Cell Treatment and Lysis in 96-Well Filter-Bottom Plates for Screening Bcr-Abl Activity and Inhibition in Whole-Cell Extracts

    PubMed Central

    MAND, MICHAEL R.; WU, DING; VEACH, DARREN R.; KRON, STEPHEN J.

    2015-01-01

    Although conventional high-throughput screens performed in vitro with purified protein kinases are powerful tools to discover new kinase inhibitors, they are far from ideal for determining efficacy in vivo. As a complementary approach, cell-based, target-driven secondary screens may help predict in vivo compound potency and specificity as well as evaluate bioavailability and toxicity. Here the authors report a simple protocol for treating K562 Bcr-Abl-expressing cells with small-molecule kinase inhibitors in 96-well filter-bottom plates followed by in-plate cell lysis. The lysates were assayed via a solid-phase kinase assay, allowing determination of apparent IC50 for known Bcr-Abl inhibitors as well as facilitating the screening of a small kinase inhibitor library. This approach may have further applications in generating lysates for analyzing kinase activity and inhibition in other nonadherent suspension cell lines. PMID:20237206

  9. Toward Biomarker Development in Large Clinical Cohorts: An Integrated High-Throughput 96-Well-Plate-Based Sample Preparation Workflow for Versatile Downstream Proteomic Analyses.

    PubMed

    Sun, Zeyu; Liu, Xiaoli; Jiang, Jing; Huang, Haijun; Wang, Jie; Wu, Daxian; Li, Lanjuan

    2016-09-01

    We describe a cheap, robust, fast, high-throughput, and flexible proteomic sample processing method based on a regular 96-well plate by acetone precipitation under low centrifuge speed (96PACS), which enables predigestion processing of 96 samples within 2 h. Tested on a complex Huh-7 total lysate, 96PACS produced comparable proteome coverage and even showed better reproducibility than FASP. Quantitative performance of 96PACS was further tested using data-independent acquisition and parallel reaction monitoring quantitation in a set of 6 benchmark samples consisting of 6 serial dilutions of BSA spiked in complex E. coli proteome background. The protocol was also successfully modified for automation and was validated in a comparative label-free proteomic study to develop serum markers for early detection of liver fibrosis and necroinflammation in patients chronically infected with hepatitis B virus. PMID:27471874

  10. CYP isoform induction screening in 96-well plates: use of 7-benzyloxy-4-trifluoromethylcoumarin as a substrate for studies with rat hepatocytes.

    PubMed

    Price, R J; Surry, D; Renwick, A B; Meneses-Lorente, G; Lake, B G; Evans, D C

    2000-08-01

    1. In this study, 7-benzyloxy-4-trifluoromethylcoumarin (BFC) was evaluated as a substrate to assess the induction of cytochrome P450 (CYP) isoform enzyme activities in rat hepatocytes using a 96-well plate format. 2. BFC was metabolized by both untreated and sodium phenobarbitone (NaPB)-treated rat hepatocytes in a time- and concentration-dependent manner to the highly fluorescent product 7-hydroxy-4-trifluoromethylcoumarin (HFC). 3. HFC was extensively conjugated with D-glucuronic acid and/or sulphate in both untreated and NaPB-treated rat hepatocytes, thus necessitating the inclusion of an enzymatic deconjugation step in the assay procedure. 4. The time-course of induction of 7-ethoxyresorufin metabolism by the CYP1A inducer beta-naphthoflavone (BNF), 7-benzyloxyresorufin metabolism by the CYP2B inducer NaPB and BFC metabolism b both BNF and NaPB was studied in rat hepatocytes treated for 24-96 h. The optimal time for induction of metabolism of all three substrates was 72 h, with no medium changes being necessary during this period. 5. The effect of treatment with 0.5-20 microM BNF, 50-2000 microM NaPB, 2-20 microM dexamethasone (DEX), 20-100 microM methylclofenapate (MCP), and 50 and 200 microM isoniazid (ISN) for 72 h on BFC metabolism in cultured rat hepatocytes was studied. BFC metabolism was induced by treatment with BNF, NaPB and MCP, but not with either DEX or ISN. 6. The metabolism of BFC in liver microsomes from the control rat and rat treated with CYP isoform inducers was also studied. BFC metabolism was induced by treatment with NaPB, BNF and DEX. 7. The metabolism of BFC was also studied using microsomes from baculovirus-infected insect cells containing rat cDNA-expressed CYP1A, CYP2B, CYP2C and CYP3A isoforms. Whereas BFC was metabolized to some extent by all the rat cDNA-expressed CYP isoforms examined, at a substrate concentration of 2.5 microM the greatest rates of BFC metabolism were observed with the CYP1A1, CYP1A2 and CYP2B1 preparations. 8

  11. Identification of photosynthesis inhibitors of pelagic marine algae using 96-well plate microfractionation for enhanced throughput in effect-directed analysis.

    PubMed

    Booij, Petra; Vethaak, A Dick; Leonards, Pim E G; Sjollema, Sascha B; Kool, Jeroen; de Voogt, Pim; Lamoree, Marja H

    2014-07-15

    Because of large-scale production and use of an increasing diversity of chemicals in modern society, estuarine and coastal waters may be contaminated with numerous substances. Some of these compounds have the potential to affect microalgae at the base of the pelagic food chain. Therefore, we identified the main chemical stressors that negatively affect the effective photosystem II efficiency (ϕPSII) in marine microalgae of the Dutch estuarine and coastal waters. An enhanced effect-directed analysis (EDA) was carried out by combining reversed-phase ultra performance liquid chromatography fractionation of extracts from passive samplers, followed by effect assessment using the pulse amplitude modulation fluorometry assay and chemical analysis of biologically active fractions using high-resolution mass spectrometry. This study focuses on a novel microfractionation technique using 96-well plates to enhance throughput in EDA, structure elucidation, and the analytical and effect confirmation of the compounds that are identified. Although there are numerous unknown compounds present in estuarine and coastal waters, our EDA study shows that atrazine, diuron, irgarol, isoproturon, terbutryn, and terbutylazine are the main contributors to the observed effect on the ϕPSII of marine microalgae. PMID:24926900

  12. A rapid method for the determination of perfluoroalkyl substances including structural isomers of perfluorooctane sulfonic acid in human serum using 96-well plates and column-switching ultra-high performance liquid chromatography tandem mass spectrometry.

    PubMed

    Salihovic, Samira; Kärrman, Anna; Lindström, Gunilla; Lind, P Monica; Lind, Lars; van Bavel, Bert

    2013-08-30

    To facilitate high-throughput analysis suitable for large epidemiological studies we developed an automated column-switching ultra-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method for determination of perfluorocarboxylic acids (PFCAs; C5, C6, C7, C8, C9, C10, C11, C12, and C13), perfluoroalkyl sulfonic acids (PFSAs; C4, C6, C8, and C10), perfluorooctane sulfonamide (PFOSA), and five groups of structural perfluorooctane sulfonic acid (PFOS) isomers in human serum or plasma. The analytical procedure involves rapid protein precipitation using 96-well plates followed by an automated sample clean-up using an on-line trap column removing many potentially interfering sample components while through the mobile phase gradient the target analytes are eluted onto the analytical column for further separation and subsequent mass detection. The method was linear (R(2)<0.995) at concentrations ranging from 0.01 to 60ngmL(-1) with method detection limits ranging between 0.01 and 0.17ngmL(-1) depending on the analyte. The developed method was precise, with repeatability (n=7) and reproducibility (n=103) coefficients of variation between 2% and 20% for most compounds including PFOS (2% and 8%) and its structural isomers (2-6% and 4-8%). The method was in conformity with a standard reference material. The column-switching HPLC-MS/MS method has been successfully applied for the determination of perfluoroalkyl substances including structural PFOS isomers in human plasma from an epidemiological study.

  13. An improved 96-well turbidity assay for T4 lysozyme activity.

    PubMed

    Toro, Tasha B; Nguyen, Thao P; Watt, Terry J

    2015-01-01

    T4 lysozyme (T4L) is an important model system for investigating the relationship between protein structure and function. Despite being extensively studied, a reliable, quantitative activity assay for T4L has not been developed. Here, we present an improved T4L turbidity assay as well as an affinity-based T4L expression and purification protocol. This assay is designed for 96-well format and utilizes conditions amenable for both T4L and other lysozymes. This protocol enables easy, efficient, and quantitative characterization of T4L variants and allows comparison between different lysozymes. Our method: •Is applicable for all lysozymes, with enhanced sensitivity for T4 lysozyme compared to other 96-well plate turbidity assays;•Utilizes standardized conditions for comparing T4 lysozyme variants and other lysozymes; and•Incorporates a simplified expression and purification protocol for T4 lysozyme.

  14. Protocol: high throughput silica-based purification of RNA from Arabidopsis seedlings in a 96-well format

    PubMed Central

    2011-01-01

    The increasing popularity of systems-based approaches to plant research has resulted in a demand for high throughput (HTP) methods to be developed. RNA extraction from multiple samples in an experiment is a significant bottleneck in performing systems-level genomic studies. Therefore we have established a high throughput method of RNA extraction from Arabidopsis thaliana to facilitate gene expression studies in this widely used plant model. We present optimised manual and automated protocols for the extraction of total RNA from 9-day-old Arabidopsis seedlings in a 96 well plate format using silica membrane-based methodology. Consistent and reproducible yields of high quality RNA are isolated averaging 8.9 μg total RNA per sample (~20 mg plant tissue). The purified RNA is suitable for subsequent qPCR analysis of the expression of over 500 genes in triplicate from each sample. Using the automated procedure, 192 samples (2 × 96 well plates) can easily be fully processed (samples homogenised, RNA purified and quantified) in less than half a day. Additionally we demonstrate that plant samples can be stored in RNAlater at -20°C (but not 4°C) for 10 months prior to extraction with no significant effect on RNA yield or quality. Additionally, disrupted samples can be stored in the lysis buffer at -20°C for at least 6 months prior to completion of the extraction procedure providing a flexible sampling and storage scheme to facilitate complex time series experiments. PMID:22136293

  15. Stretch Injury of Human Induced Pluripotent Stem Cell Derived Neurons in a 96 Well Format

    PubMed Central

    Sherman, Sydney A.; Phillips, Jack K.; Costa, J. Tighe; Cho, Frances S.; Oungoulian, Sevan R.; Finan, John D.

    2016-01-01

    Traumatic brain injury (TBI) is a major cause of mortality and morbidity with limited therapeutic options. Traumatic axonal injury (TAI) is an important component of TBI pathology. It is difficult to reproduce TAI in animal models of closed head injury, but in vitro stretch injury models reproduce clinical TAI pathology. Existing in vitro models employ primary rodent neurons or human cancer cell line cells in low throughput formats. This in vitro neuronal stretch injury model employs human induced pluripotent stem cell-derived neurons (hiPSCNs) in a 96 well format. Silicone membranes were attached to 96 well plate tops to create stretchable, culture substrates. A custom-built device was designed and validated to apply repeatable, biofidelic strains and strain rates to these plates. A high content approach was used to measure injury in a hypothesis-free manner. These measurements are shown to provide a sensitive, dose-dependent, multi-modal description of the response to mechanical insult. hiPSCNs transition from healthy to injured phenotype at approximately 35% Lagrangian strain. Continued development of this model may create novel opportunities for drug discovery and exploration of the role of human genotype in TAI pathology. PMID:27671211

  16. Establishment and validation of a method for multi-dose irradiation of cells in 96-well microplates

    SciTech Connect

    Abatzoglou, Ioannis; Zois, Christos E.; Pouliliou, Stamatia

    2013-02-15

    Highlights: ► We established a method for multi-dose irradiation of cell cultures within a 96-well plate. ► Equations to adjust to preferable dose levels are produced and provided. ► Up to eight different dose levels can be tested in one microplate. ► This method results in fast and reliable estimation of radiation dose–response curves. -- Abstract: Microplates are useful tools in chemistry, biotechnology and molecular biology. In radiobiology research, these can be also applied to assess the effect of a certain radiation dose delivered to the whole microplate, to test radio-sensitivity, radio-sensitization or radio-protection. Whether different radiation doses can be accurately applied to a single 96-well plate to further facilitate and accelerated research by one hand and spare funds on the other, is a question dealt in the current paper. Following repeated ion-chamber, TLD and radiotherapy planning dosimetry we established a method for multi-dose irradiation of cell cultures within a 96-well plate, which allows an accurate delivery of desired doses in sequential columns of the microplate. Up to eight different dose levels can be tested in one microplate. This method results in fast and reliable estimation of radiation dose–response curves.

  17. High throughput preparation of fly genomic DNA in 96-well format using a paint-shaker.

    PubMed

    Lang, Michael; Nagy, Olga; Lang, Claus; Orgogozo, Virginie

    2015-01-01

    Sample homogenization is an essential step for genomic DNA extraction, with multiple downstream applications in Molecular Biology. Genotyping hundreds or thousands of samples requires an automation of this homogenization step, and high throughput homogenizer equipment currently costs 7000 euros or more. We present an apparatus for homogenization of individual Drosophila adult flies in 96-well micro-titer dishes, which was built from a small portable paint-shaker (F5 portable paint-shaker, Ushake). Single flies are disrupted in each well that contains extraction buffer and a 4-mm metal ball. Our apparatus can hold up to five 96-well micro-titer plates. Construction of the homogenizer apparatus takes about 3-4 days, and all equipment can be obtained from a home improvement store. The total material cost is approximately 700 euros including the paint-shaker. We tested the performance of our apparatus using the ZR-96 Quick-gDNA™ kit (Zymo Research) homogenization buffer and achieved nearly complete tissue homogenization after 15 minutes of shaking. PCR tests did not detect any cross contamination between samples of neighboring wells. We obtained on average 138 ng of genomic DNA per fly, and DNA quality was adequate for standard PCR applications. In principle, our tissue homogenizer can be used for isolation of DNA suitable for library production and high throughput genotyping by Multiplexed Shotgun Genotyping (MSG), as well as RNA isolation from single flies. The sample adapter can also hold and shake other items, such as centrifuge tubes (15-50 mL) or small bottles. PMID:26818699

  18. High throughput preparation of fly genomic DNA in 96-well format using a paint-shaker

    PubMed Central

    Lang, Michael; Nagy, Olga; Lang, Claus; Orgogozo, Virginie

    2015-01-01

    Sample homogenization is an essential step for genomic DNA extraction, with multiple downstream applications in Molecular Biology. Genotyping hundreds or thousands of samples requires an automation of this homogenization step, and high throughput homogenizer equipment currently costs 7000 euros or more. We present an apparatus for homogenization of individual Drosophila adult flies in 96-well micro-titer dishes, which was built from a small portable paint-shaker (F5 portable paint-shaker, Ushake). Single flies are disrupted in each well that contains extraction buffer and a 4-mm metal ball. Our apparatus can hold up to five 96-well micro-titer plates. Construction of the homogenizer apparatus takes about 3–4 days, and all equipment can be obtained from a home improvement store. The total material cost is approximately 700 euros including the paint-shaker. We tested the performance of our apparatus using the ZR-96 Quick-gDNA™ kit (Zymo Research) homogenization buffer and achieved nearly complete tissue homogenization after 15 minutes of shaking. PCR tests did not detect any cross contamination between samples of neighboring wells. We obtained on average 138 ng of genomic DNA per fly, and DNA quality was adequate for standard PCR applications. In principle, our tissue homogenizer can be used for isolation of DNA suitable for library production and high throughput genotyping by Multiplexed Shotgun Genotyping (MSG), as well as RNA isolation from single flies. The sample adapter can also hold and shake other items, such as centrifuge tubes (15–50 mL) or small bottles. PMID:26818699

  19. Folate content in fresh-cut vegetable packed products by 96-well microtiter plate microbiological assay.

    PubMed

    Fajardo, Violeta; Alonso-Aperte, Elena; Varela-Moreiras, Gregorio

    2015-02-15

    Ready-to-eat foods have nowadays become a significant portion of the diet. Accordingly, nutritional composition of these food categories should be well-known, in particular its folate content. However, there is a broad lack of folate data in food composition tables and databases. A total of 21 fresh-cut vegetable and fruit packed products were analysed for total folate (TF) content using a validated method that relies on the folate-dependent growth of chloramphenicol-resistant Lactobacillus casei subspecies rhamnosus (NCIMB 10463). Mean TF content ranged from 10.0 to 140.9μg/100g for the different matrices on a fresh weight basis. Higher TF quantity, 140.9-70.1μg/100g, was found in spinach, rocket, watercress, chard and broccoli. Significant differences were observed between available data for fresh vegetables and fruits from food composition tables or databases and the analysed results for fresh-cut packed products. Supplied data support the potential of folate-rich fresh-cut ready-to-eat vegetables to increase folate intake significantly.

  20. HIGHLY SENSITIVE ASSAY FOR ANTICHOLINESTERASE COMPOUNDS USING 96 WELL PLATE FORMAT

    EPA Science Inventory

    One of the approaches for reducing uncertainties in the assessment of human exposure is to better characterize concentrations of hazardous compounds that may be present in our immediate environment. A significant limitation to this approach, however, is that sampling and labora...

  1. Development of a 96-well plate iodine binding assay for amylose content determination

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Cereal starch amylose/amylopectin (AM/AP) ratios are critical in functional properties for food and industrial applications. Conventional methods for the determination of AM/AP of cereal starches are very time consuming and labor intensive making it very difficult to screen large sample sets. Stud...

  2. Determining cereal starch amylose content using a dual wavelength iodine binding 96 well plate assay

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Cereal starch amylose/amylopectin (AM/AP) ratios are critical in functional properties for food and industrial applications. Conventional determination of AM/AP of cereal starches are very time consuming and labor intensive making it very difficult to screen large sample sets. Studying these large...

  3. A simple 96 well microfluidic chip combined with visual and densitometry detection for resource-poor point of care testing

    PubMed Central

    Yang, Minghui; Sun, Steven; Kostov, Yordan

    2010-01-01

    There is a well-recognized need for low cost biodetection technologies for resource-poor settings with minimal medical infrastructure. Lab-on-a-chip (LOC) technology has the ability to perform biological assays in such settings. The aim of this work is to develop a low cost, high-throughput detection system for the analysis of 96 samples simultaneously outside the laboratory setting. To achieve this aim, several biosensing elements were combined: a syringe operated ELISA lab-on-a-chip (ELISA-LOC) which integrates fluid delivery system into a miniature 96-well plate; a simplified non-enzymatic reporter and detection approach using a gold nanoparticle-antibody conjugate as a secondary antibody and silver enhancement of the visual signal; and Carbon nanotubes (CNT) to increase primary antibody immobilization and improve assay sensitivity. Combined, these elements obviate the need for an ELISA washer, electrical power for operation and a sophisticated detector. We demonstrate the use of the device for detection of Staphylococcal enterotoxin B, a major foodborne toxin using three modes of detection, visual detection, CCD camera and document scanner. With visual detection or using a document scanner to measure the signal, the limit of detection (LOD) was 0.5ng/ml. In addition to visual detection, for precise quantitation of signal using densitometry and a CCD camera, the LOD was 0.1ng/ml for the CCD analysis and 0.5 ng/ml for the document scanner. The observed sensitivity is in the same range as laboratory-based ELISA testing. The point of care device can analyze 96 samples simultaneously, permitting high throughput diagnostics in the field and in resource poor areas without ready access to laboratory facilities or electricity. PMID:21503269

  4. License Plate Recognition System for Indian Vehicles

    NASA Astrophysics Data System (ADS)

    Sanap, P. R.; Narote, S. P.

    2010-11-01

    We consider the task of recognition of Indian vehicle number plates (also called license plates or registration plates in other countries). A system for Indian number plate recognition must cope with wide variations in the appearance of the plates. Each state uses its own range of designs with font variations between the designs. Also, vehicle owners may place the plates inside glass covered frames or use plates made of nonstandard materials. These issues compound the complexity of automatic number plate recognition, making existing approaches inadequate. We have developed a system that incorporates a novel combination of image processing and artificial neural network technologies to successfully locate and read Indian vehicle number plates in digital images. Commercial application of the system is envisaged.

  5. Practical automatic Arabic license plate recognition system

    NASA Astrophysics Data System (ADS)

    Mohammad, Khader; Agaian, Sos; Saleh, Hani

    2011-02-01

    Since 1970's, the need of an automatic license plate recognition system, sometimes referred as Automatic License Plate Recognition system, has been increasing. A license plate recognition system is an automatic system that is able to recognize a license plate number, extracted from image sensors. In specific, Automatic License Plate Recognition systems are being used in conjunction with various transportation systems in application areas such as law enforcement (e.g. speed limit enforcement) and commercial usages such as parking enforcement and automatic toll payment private and public entrances, border control, theft and vandalism control. Vehicle license plate recognition has been intensively studied in many countries. Due to the different types of license plates being used, the requirement of an automatic license plate recognition system is different for each country. [License plate detection using cluster run length smoothing algorithm ].Generally, an automatic license plate localization and recognition system is made up of three modules; license plate localization, character segmentation and optical character recognition modules. This paper presents an Arabic license plate recognition system that is insensitive to character size, font, shape and orientation with extremely high accuracy rate. The proposed system is based on a combination of enhancement, license plate localization, morphological processing, and feature vector extraction using the Haar transform. The performance of the system is fast due to classification of alphabet and numerals based on the license plate organization. Experimental results for license plates of two different Arab countries show an average of 99 % successful license plate localization and recognition in a total of more than 20 different images captured from a complex outdoor environment. The results run times takes less time compared to conventional and many states of art methods.

  6. A highly sensitive and versatile virus titration assay in the 96-well microplate format.

    PubMed

    Borisevich, V; Nistler, R; Hudman, D; Yamshchikov, G; Seregin, A; Yamshchikov, V

    2008-02-01

    This report describes a fast, reproducible, inexpensive and convenient assay system for virus titration in the 96-well format. The micromethod substantially increases assay throughput and improves the data reproducibility. A highly simplified variant of virus quantification is based on immunohistochemical detection of virus amplification foci obtained without use of agarose or semisolid overlays. It can be incorporated into several types of routine virological assays successfully replacing the laborious and time-consuming conventional methods based on plaque formation under semisolid overlays. The method does not depend on the development of CPE and can be accommodated to assay viruses with substantial differences in growth properties. The use of enhanced immunohistochemical detection enabled a five- to six-fold reduction of the total assay time. The micromethod was specifically developed to take advantage of multichannel pipettor use to simplify handling of a large number of samples. The method performs well with an inexpensive low-power binocular, thus offering a routine assay system usable outside of specialized laboratory setting, such as for testing of clinical or field samples. When used in focus reduction-neutralization tests (FRNT), the method accommodates very small volumes of immune serum, which is often a decisive factor in experiments involving small rodent models.

  7. Lighting system with heat distribution face plate

    DOEpatents

    Arik, Mehmet; Weaver, Stanton Earl; Stecher, Thomas Elliot; Kuenzler, Glenn Howard; Wolfe, Jr., Charles Franklin; Li, Ri

    2013-09-10

    Lighting systems having a light source and a thermal management system are provided. The thermal management system includes synthetic jet devices, a heat sink and a heat distribution face plate. The synthetic jet devices are arranged in parallel to one and other and are configured to actively cool the lighting system. The heat distribution face plate is configured to radially transfer heat from the light source into the ambient air.

  8. 96-well format-based microfluidic platform for parallel interconnection of multiple multicellular spheroids.

    PubMed

    Kim, Jin-Young; Fluri, David A; Kelm, Jens M; Hierlemann, Andreas; Frey, Olivier

    2015-06-01

    In this article, we present a microfluidic platform, compatible with conventional 96-well formats, that enables facile and parallelized culturing and testing of spherical microtissues in a standard incubator. The platform can accommodate multiple microtissues (up to 66) of different cell types, formed externally by using the hanging-drop method, and enables microtissue interconnection through microfluidic channels for continuous media perfusion or dosage of substances. The platform contains 11 separate channels, and each channel has six tissue compartments. Primary rat liver tissues were cultured over 8 days, and multiple tumor tissues (HCT116) were exposed to various concentrations of 5-fluorouracil for platform characterization.

  9. Development of a quantitative 96-well method to image glycogen storage in primary rat hepatocytes.

    PubMed

    Pilling, James; Garside, Helen; Ainscow, Edward

    2010-08-01

    Within the liver, hormonal control of glycogen metabolism allows for rapid release and uptake of glucose from the circulation, providing a reserve of glucose that can be utilised by other organs. Traditionally, cellular glycogen storage has been detected using Periodic acid Schiff (PAS) staining of histopathology samples or a biochemical assay. Colorimetric measurement of glycogen content using PAS staining is hard to quantify whilst biochemical techniques give limited information about events such as cytotoxicity or allow analysis of hepatic heterogeneity. Here, we describe the development of an imaging based method to quantify glycogen storage in 96-well cultures of primary rat hepatocytes using the inherent fluorescence properties of the Schiff reagent. PAS-stained hepatocytes were imaged using an automated fluorescent microscope, with the amount of glycogen present in each cell being quantified. Using this technique, we found an increase in glycogen storage in response to insulin (EC50 = 0.31 nM) that was in agreement with that determined using biochemical quantification (EC50 = 0.32 nM). Furthermore, a dose dependent increase in glycogen storage was also seen in response to glycogen synthase kinase inhibitors and glycogen phosphorylase inhibitors. This technique allows rapid assessment of cellular glycogen storage in response to hormones and small molecule inhibitors.

  10. Automated expression and solubility screening of His-tagged proteins in 96-well format.

    PubMed

    Vincentelli, Renaud; Canaan, Stéphane; Offant, Julien; Cambillau, Christian; Bignon, Christophe

    2005-11-01

    A growing need for sensitive and high-throughput methods for screening the expression and solubility of recombinant proteins exists in structural genomics. Originally, the emergency solution was to use immediately available techniques such as manual lysis of expression cells followed by analysis of protein expression by gel electrophoresis. However, these handmade methods quickly proved to be unfit for the high-throughput demand of postgenomics, and it is now generally accepted that the long-term solution to this problem will be based on automation, on industrial standard-formatted experiments, and on downsizing samples and consumables. In agreement with this consensus, we have set up a fully automated method based on a dot-blot technology and using 96-well format consumables for assessing by immunodetection the amount of total and soluble recombinant histidine (His)-tagged proteins expressed in Escherichia coli. The method starts with the harvest of expression cells and ends with the display of solubility/expression results in milligrams of recombinant protein per liter of culture using a three-color code to assist analysis. The program autonomously processes 160 independent cultures at a time.

  11. Detection of enteroviruses in shellfish by fluorogenic polymerase chain reaction integrated with 96-well microplate scanning.

    PubMed

    Shieh, Y Carol; Baric, Ralph S

    2002-01-01

    A one-step procedure was developed to confirm viral targets by using a fluorometric 96-well microplate scanner following polymerase chain reaction (PCR). The fluorogenic PCR, integrated with fluorometric scanning, measured the end point fluorescence of viral PCR amplicon/probe hybrids and permitted the use of nonfluorogenic PCR conditions with addition of a Cy3 fluorophore-labeled linear probe for viruses. This linear probe generated higher ratios of viral signal-to-noise than a comparative beacon probe. Detection efficiency with a Cy3/quencher linear probe was comparable with Southern analysis at the level > or = 0.27 plaque-forming units (PFU) of poliovirus/PCR. For the reaction containing < 0.27 PFU, the fluorometric measurements of the first-round PCR viral amplicon were not as sensitive as Southern analysis; however, equivalent sensitivities were achieved with fluorogenic nested PCR. Concentrates of 11 oyster samples exposed to municipal sewage were tested for enteroviruses; the fluorogenic detection correlated 100% with Southern analysis. This method using fluorometric scanning of viral amplicon is simple; it requires neither continuously monitoring equipment nor redesigning PCR primers; and it accurately detects enteroviruses in oyster sample concentrates in less time than classic spectrophotometry or Southern analysis.

  12. Enzyme activity assay of glycoprotein enzymes based on a boronate affinity molecularly imprinted 96-well microplate.

    PubMed

    Bi, Xiaodong; Liu, Zhen

    2014-12-16

    Enzyme activity assay is an important method in clinical diagnostics. However, conventional enzyme activity assay suffers from apparent interference from the sample matrix. Herein, we present a new format of enzyme activity assay that can effectively eliminate the effects of the sample matrix. The key is a 96-well microplate modified with molecularly imprinted polymer (MIP) prepared according to a newly proposed method called boronate affinity-based oriented surface imprinting. Alkaline phosphatase (ALP), a glycoprotein enzyme that has been routinely used as an indicator for several diseases in clinical tests, was taken as a representative target enzyme. The prepared MIP exhibited strong affinity toward the template enzyme (with a dissociation constant of 10(-10) M) as well as superb tolerance for interference. Thus, the enzyme molecules in a complicated sample matrix could be specifically captured and cleaned up for enzyme activity assay, which eliminated the interference from the sample matrix. On the other hand, because the boronate affinity MIP could well retain the enzymatic activity of glycoprotein enzymes, the enzyme captured by the MIP was directly used for activity assay. Thus, additional assay time and possible enzyme or activity loss due to an enzyme release step required by other methods were avoided. Assay of ALP in human serum was successfully demonstrated, suggesting a promising prospect of the proposed method in real-world applications.

  13. Parallel Plate System for Collecting Data Used to Determine Viscosity

    NASA Technical Reports Server (NTRS)

    Kaukler, William (Inventor); Ethridge, Edwin C. (Inventor)

    2013-01-01

    A parallel-plate system collects data used to determine viscosity. A first plate is coupled to a translator so that the first plate can be moved along a first direction. A second plate has a pendulum device coupled thereto such that the second plate is suspended above and parallel to the first plate. The pendulum device constrains movement of the second plate to a second direction that is aligned with the first direction and is substantially parallel thereto. A force measuring device is coupled to the second plate for measuring force along the second direction caused by movement of the second plate.

  14. A 96-well single-pot protein precipitation, liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the determination of muraglitazar, a novel diabetes drug, in human plasma.

    PubMed

    Xue, Y-J; Liu, Jane; Pursley, Janice; Unger, Steve

    2006-02-01

    A 96-well single-pot protein precipitation, liquid chromatography/tandem mass spectrometry (LC/MS/MS) method has been developed and validated for the determination of muraglitazar, a PPAR alpha/gamma dual agonist, in human plasma. The internal standard, a chemical analogue, was dissolved in acetonitrile containing 0.1% formic acid. The solvent system was also served as a protein precipitation reagent. Human plasma samples (0.1 mL) and the internal standard solution (0.3 mL) were added to a 96-well plate. The plate was vortexed for 1 min and centrifuged for 5 min. Then the supernatant layers were directly injected into the LC/MS/MS system. The chromatographic separation was achieved isocratically on a Phenomenox C18(2) Luna column (2 mm x 50 mm, 5 microm). The mobile phase contained 20/80 (v/v) of water and acetonitrile containing 0.1% formic acid. Detection was by positive ion electrospray tandem mass spectrometry on a Sciex API 3000. The standard curve, which ranged from 1 to 1000 ng/mL, was fitted to a 1/x weighted quadratic regression model. This single-pot approach effectively eliminated three time consuming sample preparation steps: sample transfer, dry-down, and reconstitution before the injection, while it preserved all the benefits of the traditional protein precipitation. By properly adjusting the autosampler needle offset level, only the supernatant was injected, without disturbing the precipitated proteins in the bottom. As a result, the quality of chromatography and column life were not compromised. After more than 600 injections, there was only slightly increase of column back-pressure. The validation results demonstrated that this method was rugged and provide satisfactory precision and accuracy. The method has been successfully applied to analyze human plasma samples in support of a first-in-man study. This method has also been validated in monkey and mouse plasma for the determination of muraglitazar. PMID:16388995

  15. GT1-7 cell-based cytoxicity screening assay on 96-well microplates as a platform for the safety assessment of genetically modified Gerbera hybrida extracts.

    PubMed

    Fallarero, Adyary; Ainasoja, Miia; Sandberg, Malena; Teeri, Teemu H; Vuorela, Pia M

    2009-01-01

    In this investigation, a GT1-7 cell-based cytotoxicity screening assay in 96-well microplates was set up. The assay, using propidium iodide fluorescence, was proven to be reliable, with good quality (Z' = 0.51) and low plate-to-plate and day-to-day variations. Further on, a library containing extracts from 227 genetic modification (GM) Gerbera hybrida and 42 Gerbera varieties was screened; however, no differences between them were found. Based on these findings, we propose the use of the current assay within the first-tier screening studies of large collections. Also, these results provide valuable information for GM Gerbera risk-assessment purposes and offer a model for the toxicity cell-based screening of GM crops.

  16. Root-Contact/Pressure-Plate Assembly For Hydroponic System

    NASA Technical Reports Server (NTRS)

    Morris, Carlton E.; Loretan, Philip A.; Bonsi, Conrad K.; Hill, Walter A.

    1994-01-01

    Hydroponic system includes growth channels equipped with rootcontact/pressure-plate assemblies. Pump and associated plumbing circulate nutrient liquid from reservoir, along bottom of growth channels, and back to reservoir. Root-contact/pressure-plate assembly in each growth channel stimulates growth of roots by applying mild contact pressure. Flat plate and plate connectors, together constitute pressure plate, free to move upward to accommodate growth of roots. System used for growing sweetpotatoes and possibly other tuber and root crops.

  17. Free Vibration of a Rectangular Plate-Beam Coupled System

    NASA Astrophysics Data System (ADS)

    Chiba, M.; Yoshida, I.

    1996-07-01

    A free vibration analysis by the Rayleigh-Ritz method is presented for a rectangular plate-beam coupled system. The system consists of a cantilever rectangular plate and either a pair of beams or a single beam connected to the free end side furthest away from the support. Natural frequencies and vibration modes are provided for various system configurations: i.e., the length ratio between the plate and the beam, the aspect ratio of the plate, and the distance between beams. To confirm the validity of the analysis, an experiment was also conducted, with polystyrene test plates of 0·5 mm thickness. The respective results are in good agreement.

  18. Composite Bipolar Plate for Unitized Fuel Cell/Electrolyzer Systems

    NASA Technical Reports Server (NTRS)

    Mittelsteadt, Cortney K.; Braff, William

    2009-01-01

    In a substantial improvement over present alkaline systems, an advanced hybrid bipolar plate for a unitized fuel cell/electrolyzer has been developed. This design, which operates on pure feed streams (H2/O2 and water, respectively) consists of a porous metallic foil filled with a polymer that has very high water transport properties. Combined with a second metallic plate, the pore-filled metallic plates form a bipolar plate with an empty cavity in the center.

  19. Orion Boiler Plate Airdrop Test System

    NASA Technical Reports Server (NTRS)

    Machin, Ricardo A.; Evans, Carol T.

    2013-01-01

    On the 29th of February 2012 the Orion Capsule Parachute Assembly System (CPAS) project attempted to perform an airdrop test of a boilerplate test article for the second time. The first attempt (Cluster Development Test 2, July 2008) to deliver a similar boilerplate from a C-17 using the Low Velocity Air Drop (LVAD) technique resulted in the programmer parachute failing to properly inflate, the test article failing to achieve the desired test initiation conditions, and the test article a total loss. This paper will pick up where the CDT-2 failure investigation left off, describing the test technique that was adopted, and outline the modeling that was performed to gain confidence that the second attempt would be successful. The second boiler plate test (Cluster Development Test 3-3) was indeed a complete success and has subsequently been repeated several times, allowing the CPAS project to proceed with the full scale system level development testing required to integrate the hardware to the first Entry Flight Test vehicle as well as go into the Critical Design Review with minimum risk and a mature design.

  20. Plate Tectonics, Geographical Information System, paleogeography

    SciTech Connect

    Moore, Thomas L.; Scotese, Christopher

    2002-05-24

    The PaleoX.framwork is a dynamically linked/loaded framework for Cocoa applications. The primary goal of this library is to standardize several elements used for working with paleogeographic data. This includes objects designed to organize information for tectonic plates, including maps, rotation objects, plate names, and designations. In addition, PaleoX provides object-oriented solutions for handling standard paleogeographic file formats from the PALEOMAP Project.

  1. Automation of in-tip solid-phase microextraction in 96-well format for the determination of a model drug compound in human plasma by liquid chromatography with tandem mass spectrometric detection.

    PubMed

    Xie, W; Mullett, W M; Miller-Stein, C M; Pawliszyn, J

    2009-02-01

    Studies using in-tip solid phase microextraction (in-tip SPME) in a 96-well plate format are conducted to investigate the feasibility of SPME automation. The sample preparation process, including extraction and desorption, was fully automated and coupled with currently commercially available automated liquid handling systems. Several process parameters including extraction time and speed, and desorption time were investigated. An LC-MS/MS method has been developed and validated to determine the levels of a drug compound (MK-0533) in human plasma that demonstrates the suitability of this new approach. The developed method has a lower limit of quantitation (LLOQ) of 5 ng/mL when 0.25 mL of human plasma is processed and is validated in the concentration range of 5-2, 000 ng/mL. The successful application of the assay in clinical sample analysis indicates that in-tip SPME can be easily automated and has great potential to be used for high throughput quantitative determination of drugs in pharmaceutical industry.

  2. Characterization of multiple platelet activation pathways in patients with bleeding as a high-throughput screening option: use of 96-well Optimul assay

    PubMed Central

    Lordkipanidzé, Marie; Lowe, Gillian C.; Kirkby, Nicholas S.; Chan, Melissa V.; Lundberg, Martina H.; Morgan, Neil V.; Bem, Danai; Nisar, Shaista P.; Leo, Vincenzo C.; Jones, Matthew L.; Mundell, Stuart J.; Daly, Martina E.; Mumford, Andrew D.; Warner, Timothy D.; Watson, Steve P.; Watson, Steve P.; Mumford, Andrew D.; Mundell, Stuart J.; Gissen, Paul; Daly, Martina E.; Lester, Will; Clark, Justin; Williams, Mike; Motwani, Jayashree; Marshall, Dianne; Nyatanga, Priscilla; Mann, Pat; Kirwan, Julie; Wilde, Jonathan; Dunkley, Tracey; Greenway, April; Makris, Michael; Pavord, Sue; Dattani, Rashesh; Grimley, Gerry Dolan Charlotte; Stokley, Simone; Astwood, Emma; Chang, Cherry; Foros, Merri; Trower, Linda; Thachil, Jecko; Hay, Charlie; Pike, Gill; Will, Andrew; Grainger, John; Foulkes, Matt; Fareh, Mona; Talks, Kate; Biss, Tina; Kesteven, Patrick; Hanley, John; Vowles, Julie; Basey, Lesley; Barnes, Michelle; Collins, Peter; Rayment, Rachel; Alikhan, Raza; Morris, Ana Guerrero Rebecca; Mansell, Dianne; Toh, Cheng Hock; Martlew, Vanessa; Murphy, Elaine; Lachmann, Robin; Rose, Peter; Chapman, Oliver; Lokare, Anand; Marshall, Kathryn; Khan, Naseem; Keeling, David; Giangrande, Paul; Austin, Steve; Bevan, David; Alamelu, Jayanthi

    2014-01-01

    Up to 1% of the population have mild bleeding disorders, but these remain poorly characterized, particularly with regard to the roles of platelets. We have compared the usefulness of Optimul, a 96-well plate-based assay of 7 distinct pathways of platelet activation to characterize inherited platelet defects in comparison with light transmission aggregometry (LTA). Using Optimul and LTA, concentration-response curves were generated for arachidonic acid, ADP, collagen, epinephrine, Thrombin receptor activating-peptide, U46619, and ristocetin in samples from (1) healthy volunteers (n = 50), (2) healthy volunteers treated with antiplatelet agents in vitro (n = 10), and (3) patients with bleeding of unknown origin (n = 65). The assays gave concordant results in 82% of cases (κ = 0.62, P < .0001). Normal platelet function results were particularly predictive (sensitivity, 94%; negative predictive value, 91%), whereas a positive result was not always substantiated by LTA (specificity, 67%; positive predictive value, 77%). The Optimul assay was significantly more sensitive at characterizing defects in the thromboxane pathway, which presented with normal responses with LTA. The Optimul assay is sensitive to mild platelet defects, could be used as a rapid screening assay in patients presenting with bleeding symptoms, and detects changes in platelet function more readily than LTA. This trial was registered at www.isrctn.org as #ISRCTN 77951167. PMID:24408324

  3. Note: Heated flyer-plate impact system.

    PubMed

    Dolan, D H; Seagle, C T; Ao, T; Hacking, R G

    2014-07-01

    A technique for launching heated flyer plates was developed on a single-stage gas gun. This type of impact creates a well-posed mechanical state and a tunable thermal state, which is useful for calibrating dynamic temperature measurements. Proof-of-principle thermoreflectance measurements were performed using this technique. Since the target remains at room temperature until the moment of impact, heated flyers avoid differential expansion and annealing issues, allowing novel impact experiments to be performed. PMID:25085187

  4. Note: Heated flyer-plate impact system.

    PubMed

    Dolan, D H; Seagle, C T; Ao, T; Hacking, R G

    2014-07-01

    A technique for launching heated flyer plates was developed on a single-stage gas gun. This type of impact creates a well-posed mechanical state and a tunable thermal state, which is useful for calibrating dynamic temperature measurements. Proof-of-principle thermoreflectance measurements were performed using this technique. Since the target remains at room temperature until the moment of impact, heated flyers avoid differential expansion and annealing issues, allowing novel impact experiments to be performed.

  5. CometChip: a high-throughput 96-well platform for measuring DNA damage in microarrayed human cells.

    PubMed

    Ge, Jing; Prasongtanakij, Somsak; Wood, David K; Weingeist, David M; Fessler, Jessica; Navasummrit, Panida; Ruchirawat, Mathuros; Engelward, Bevin P

    2014-10-18

    DNA damaging agents can promote aging, disease and cancer and they are ubiquitous in the environment and produced within human cells as normal cellular metabolites. Ironically, at high doses DNA damaging agents are also used to treat cancer. The ability to quantify DNA damage responses is thus critical in the public health, pharmaceutical and clinical domains. Here, we describe a novel platform that exploits microfabrication techniques to pattern cells in a fixed microarray. The 'CometChip' is based upon the well-established single cell gel electrophoresis assay (a.k.a. the comet assay), which estimates the level of DNA damage by evaluating the extent of DNA migration through a matrix in an electrical field. The type of damage measured by this assay includes abasic sites, crosslinks, and strand breaks. Instead of being randomly dispersed in agarose in the traditional assay, cells are captured into an agarose microwell array by gravity. The platform also expands from the size of a standard microscope slide to a 96-well format, enabling parallel processing. Here we describe the protocols of using the chip to evaluate DNA damage caused by known genotoxic agents and the cellular repair response followed after exposure. Through the integration of biological and engineering principles, this method potentiates robust and sensitive measurements of DNA damage in human cells and provides the necessary throughput for genotoxicity testing, drug development, epidemiological studies and clinical assays.

  6. Global Plate Velocities from the Global Positioning System

    NASA Technical Reports Server (NTRS)

    Larson, Kristine M.; Freymueller, Jeffrey T.; Philipsen, Steven

    1997-01-01

    We have analyzed 204 days of Global Positioning System (GPS) data from the global GPS network spanning January 1991 through March 1996. On the basis of these GPS coordinate solutions, we have estimated velocities for 38 sites, mostly located on the interiors of the Africa, Antarctica, Australia, Eurasia, Nazca, North America, Pacific, and South America plates. The uncertainties of the horizontal velocity components range from 1.2 to 5.0 mm/yr. With the exception of sites on the Pacific and Nazca plates, the GPS velocities agree with absolute plate model predictions within 95% confidence. For most of the sites in North America, Antarctica, and Eurasia, the agreement is better than 2 mm/yr. We find no persuasive evidence for significant vertical motions (less than 3 standard deviations), except at four sites. Three of these four were sites constrained to geodetic reference frame velocities. The GPS velocities were then used to estimate angular velocities for eight tectonic plates. Absolute angular velocities derived from the GPS data agree with the no net rotation (NNR) NUVEL-1A model within 95% confidence except for the Pacific plate. Our pole of rotation for the Pacific plate lies 11.5 deg west of the NNR NUVEL-1A pole, with an angular speed 10% faster. Our relative angular velocities agree with NUVEL-1A except for some involving the Pacific plate. While our Pacific-North America angular velocity differs significantly from NUVEL-1A, our model and NUVEL-1A predict very small differences in relative motion along the Pacific-North America plate boundary itself. Our Pacific-Australia and Pacific- Eurasia angular velocities are significantly faster than NUVEL-1A, predicting more rapid convergence at these two plate boundaries. Along the East Pacific Pise, our Pacific-Nazca angular velocity agrees in both rate and azimuth with NUVFL-1A.

  7. Imaging and quantitative analysis of tritium-labelled cells in lymphocyte proliferation assays using microchannel plate detectors originally developed for X-ray astronomy.

    PubMed

    Lees, J E; Hales, J M

    2001-01-01

    Microchannel plate detectors have been used in many astronomical X-ray telescopes. Recently we have begun to use similar detectors to image electron emission from radiolabelled biological assays. Here we show how a microchannel plate (MCP) detector can be used to image tritium uptake in T lymphocyte proliferation assays. Quantitative analysis using the MCP detector has the same sensitivity and speed as conventional liquid scintillation counter (LSC) analysis whilst obviating the need for scintillation fluid. In addition the system permits the imaging of whole plate harvests from a range of plate sizes. Here we present data obtained with 96-well plates and Terasaki plates.

  8. Imaging and quantitative analysis of tritium-labelled cells in lymphocyte proliferation assays using microchannel plate detectors originally developed for X-ray astronomy.

    PubMed

    Lees, J E; Hales, J M

    2001-01-01

    Microchannel plate detectors have been used in many astronomical X-ray telescopes. Recently we have begun to use similar detectors to image electron emission from radiolabelled biological assays. Here we show how a microchannel plate (MCP) detector can be used to image tritium uptake in T lymphocyte proliferation assays. Quantitative analysis using the MCP detector has the same sensitivity and speed as conventional liquid scintillation counter (LSC) analysis whilst obviating the need for scintillation fluid. In addition the system permits the imaging of whole plate harvests from a range of plate sizes. Here we present data obtained with 96-well plates and Terasaki plates. PMID:11150540

  9. Rapid 96-well plates DNA extraction and sequencing procedures to identify genome-wide transposon insertion sites in a difficult to lyse bacterium: Lactobacillus casei.

    PubMed

    Scornec, Hélène; Tichit, Magali; Bouchier, Christiane; Pédron, Thierry; Cavin, Jean-François; Sansonetti, Philippe J; Licandro-Seraut, Hélène

    2014-11-01

    Random transposon mutagenesis followed by adequate screening methods is an unavoidable procedure to characterize genetics of bacterial adaptation to environmental changes. We have recently constructed a mutant library of Lactobacillus casei and we aimed to fully annotate it. However, we have observed that, for L. casei which is a difficult to lyse bacterium, methods used to identify the transposon insertion site in a few mutants (transposon rescue by restriction and recircularization or PCR-based methods) were not transposable for a larger number because they are too time-consuming and sometimes not reliable. Here, we describe a method for large-scale and reliable identification of transposon insertion sites in a L. casei mutant library of 9250 mutants. DNA extraction procedure based on silica membranes in 96-column format was optimized to obtain genomic DNA from a large number of mutants. Then reliable direct genomic sequencing was improved to fit the obtained genomic DNA extracts. Using this procedure, readable and identifiable sequences were obtained for 87% of the L. casei mutants. This method extends the applications of a library of this type, reduces the number of insertions needed to be screened, and allows selection of specific mutants from an arrayed and stored mutant library. This method is applicable to any already existing mutant library (obtained by transposon or insertional mutagenesis) and could be useful for other bacterial species, especially for highly lysis-resistant bacteria species such as lactic acid bacteria.

  10. Study of plate-fin heat exchanger and cold plate for the active thermal control system of Space Station

    NASA Technical Reports Server (NTRS)

    Chyu, MING-C.

    1992-01-01

    Plate-fin heat exchangers will be employed in the Active Thermal Control System of Space Station Freedom. During ground testing of prototypic heat exchangers, certain anomalous behaviors have been observed. Diagnosis has been conducted to determine the cause of the observed behaviors, including a scrutiny of temperature, pressure, and flow rate test data, and verification calculations based on such data and more data collected during the ambient and thermal/vacuum tests participated by the author. The test data of a plate-fin cold plate have been also analyzed. Recommendation was made with regard to further tests providing more useful information of the cold plate performance.

  11. Fiber-coupled laser-driven flyer plates system.

    PubMed

    Zhao, Xing-hai; Zhao, Xiang; Shan, Guang-cun; Gao, Yang

    2011-04-01

    A system for the launch of hypervelocity flyer plates has been developed and characterized. Laser-driven flyers were launched from the substrate backed aluminum-alumina-aluminum sandwiched films. A laser-induced plasma is used to drive flyers with typical thickness of 5.5 μm and diameters of less than 1 mm, to achieve velocities of a few km/s. These flyer plates have many applications, from micrometeorite simulation to laser ignition. The flyer plates considered here have up to three layers: an ablation layer, to form plasma; an insulating layer; and a final, thicker layer that forms the final flyer plates. This technique was developed aiming at improving the energy efficiency of the system. The kinetic energy of flyers launched with the additional layer was found to be enhanced by a factor of near 2 (up to 30%). The optical fiber delivery system governs the output spatial profile of the laser spot and power capacity. Moreover, a technique for coupling high-power laser pulses into an optical fiber has been developed. This fiber optic system has been successfully used to launch flyer plates, and the surface finishing quality of the fiber was found to be an important factor. Importantly, measurements of the flyer performance including the mean velocities and planarity were made by an optical time-of-arrival technique using an optical fiber array probe, demonstrating the good planarity of the flyer and the achievable average velocity of 1.7 km/s with approaching 1 mm diameter. Finally, the relationship between flyer velocities and incident laser pulses energy was also investigated.

  12. Fiber-coupled laser-driven flyer plates system

    NASA Astrophysics Data System (ADS)

    Zhao, Xing-hai; Zhao, Xiang; Shan, Guang-cun; Gao, Yang

    2011-04-01

    A system for the launch of hypervelocity flyer plates has been developed and characterized. Laser-driven flyers were launched from the substrate backed aluminum-alumina-aluminum sandwiched films. A laser-induced plasma is used to drive flyers with typical thickness of 5.5 μm and diameters of less than 1 mm, to achieve velocities of a few km/s. These flyer plates have many applications, from micrometeorite simulation to laser ignition. The flyer plates considered here have up to three layers: an ablation layer, to form plasma; an insulating layer; and a final, thicker layer that forms the final flyer plates. This technique was developed aiming at improving the energy efficiency of the system. The kinetic energy of flyers launched with the additional layer was found to be enhanced by a factor of near 2 (up to 30%). The optical fiber delivery system governs the output spatial profile of the laser spot and power capacity. Moreover, a technique for coupling high-power laser pulses into an optical fiber has been developed. This fiber optic system has been successfully used to launch flyer plates, and the surface finishing quality of the fiber was found to be an important factor. Importantly, measurements of the flyer performance including the mean velocities and planarity were made by an optical time-of-arrival technique using an optical fiber array probe, demonstrating the good planarity of the flyer and the achievable average velocity of 1.7 km/s with approaching 1 mm diameter. Finally, the relationship between flyer velocities and incident laser pulses energy was also investigated.

  13. Plate-Based Fuel Processing System Final Report

    SciTech Connect

    Carlos Faz; Helen Liu; Jacques Nicole; David Yee

    2005-12-22

    On-board reforming of liquid fuels into hydrogen is an enabling technology that could accelerate consumer usage of fuel cell powered vehicles. The technology would leverage the convenience of the existing gasoline fueling infrastructure while taking advantage of the fuel cell efficiency and low emissions. Commercial acceptance of on-board reforming faces several obstacles that include: (1) startup time, (2) transient response, and (3) system complexity (size, weight and cost). These obstacles are being addressed in a variety of projects through development, integration and optimization of existing fuel processing system designs. In this project, CESI investigated steam reforming (SR), water-gas-shift (WGS) and preferential oxidation (PrOx) catalysts while developing plate reactor designs and hardware where the catalytic function is integrated into a primary surface heat exchanger. The plate reactor approach has several advantages. The separation of the reforming and combustion streams permits the reforming reaction to be conducted at a higher pressure than the combustion reaction, thereby avoiding costly gas compression for combustion. The separation of the two streams also prevents the dilution of the reformate stream by the combustion air. The advantages of the plate reactor are not limited to steam reforming applications. In a WGS or PrOx reaction, the non-catalytic side of the plate would act as a heat exchanger to remove the heat generated by the exothermic WGS or PrOx reactions. This would maintain the catalyst under nearly isothermal conditions whereby the catalyst would operate at its optimal temperature. Furthermore, the plate design approach results in a low pressure drop, rapid transient capable and attrition-resistant reactor. These qualities are valued in any application, be it on-board or stationary fuel processing, since they reduce parasitic losses, increase over-all system efficiency and help perpetuate catalyst durability. In this program, CESI

  14. System Advisor Model: Flat Plate Photovoltaic Performance Modeling Validation Report

    SciTech Connect

    Freeman, J.; Whitmore, J.; Kaffine, L.; Blair, N.; Dobos, A. P.

    2013-12-01

    The System Advisor Model (SAM) is a free software tool that performs detailed analysis of both system performance and system financing for a variety of renewable energy technologies. This report provides detailed validation of the SAM flat plate photovoltaic performance model by comparing SAM-modeled PV system generation data to actual measured production data for nine PV systems ranging from 75 kW to greater than 25 MW in size. The results show strong agreement between SAM predictions and field data, with annualized prediction error below 3% for all fixed tilt cases and below 8% for all one axis tracked cases. The analysis concludes that snow cover and system outages are the primary sources of disagreement, and other deviations resulting from seasonal biases in the irradiation models and one axis tracking issues are discussed in detail.

  15. Sensor network based vehicle classification and license plate identification system

    SciTech Connect

    Frigo, Janette Rose; Brennan, Sean M; Rosten, Edward J; Raby, Eric Y; Kulathumani, Vinod K

    2009-01-01

    Typically, for energy efficiency and scalability purposes, sensor networks have been used in the context of environmental and traffic monitoring applications in which operations at the sensor level are not computationally intensive. But increasingly, sensor network applications require data and compute intensive sensors such video cameras and microphones. In this paper, we describe the design and implementation of two such systems: a vehicle classifier based on acoustic signals and a license plate identification system using a camera. The systems are implemented in an energy-efficient manner to the extent possible using commercially available hardware, the Mica motes and the Stargate platform. Our experience in designing these systems leads us to consider an alternate more flexible, modular, low-power mote architecture that uses a combination of FPGAs, specialized embedded processing units and sensor data acquisition systems.

  16. Utility operation of a flat plate photovoltaic system

    NASA Astrophysics Data System (ADS)

    Hernandez, E.; Risser, V.

    The 20-kilowatt El Paso Photovoltaic Project is one of four PRDA-38 flat-plate experiments. This system was designed, constructed, and integrated onto an existing uninterruptable power supply (UPS) at the El Paso Electric Company's Newman Power Station. The system has provided more than 49,000 kilowatt-hours to the load in the first 19 months. A two year partially DOE-funded operation and maintenance cooperative agreement is currently in place with the New Mexico Solar Energy Institute as prime contractor. During this period, the responsibility for this system will be transferred to El Paso Electric. To ensure that capability for independent system operation, maintenance, and evaluation was available at El Paso Electric, certain tasks were initiated and are discussed in this paper.

  17. Evolution of the Mariana Convergent Plate Margin System

    NASA Astrophysics Data System (ADS)

    Fryer, Patricia

    1996-02-01

    The Mariana convergent plate margin system of the western Pacific provides opportunities for studying the tectonic and geochemical processes of intraoceanic plate subduction without the added complexities of continental geology. The system's relative geologic simplicity and the well-exposed sections of lithosphere in each of its tectonic provinces permit in situ examination of processes critical to understanding subduction tectonics. Its general history provides analogs to ancient convergent margin terranes exposed on land and helps to explain the chemical mass balance in convergent plate margins. The Mariana convergent margin's long history of sequential formation of volcanic arcs and extensional back arc basins has created a series of volcanic arcs at the eastern edge of the Philippine Sea plate. The trenchward edge of the overriding plate has a relatively sparse sediment cover. Rocks outcropping on the trench's inner slope are typical of the early formed suprasubduction zone's lithosphere and have been subjected to various processes related to its tectonic history. Pervasive forearc faulting has exposed crust and upper mantle lithosphere. Many large serpentinized peridotite seamounts are within 100 km of the trench axis. From these we can learn the history of regional metamorphism and observe and sample active venting of slab fluids. Ocean drilling recovered suprasubduction zone lava sequences erupted since the Eocene that suggest that the forearc region remains volcanologically dynamic. Seismic studies and seafloor mapping show evidence of deformation throughout forearc evolution. Large portions of uplifted southern forearc are exposed at the larger islands. Active volcanoes at the base of the eastern boundary fault of the Mariana Trough vary in size and composition along strike and record regional differences in source composition. Their locations along strike of the arc are controlled in part by cross-arc structures that also facilitate formation of submarine

  18. Convection pattern and stress system under the African plate

    NASA Technical Reports Server (NTRS)

    Liu, H.-S.

    1977-01-01

    Studies on tectonic forces from satellite-derived gravity data have revealed a subcrustal stress system which provides a unifying mechanism for uplift, depression, rifting, plate motion and ore formation in Africa. The subcrustal stresses are due to mantle convection. Seismicity, volcanicity and kimberlite magmatism in Africa and the development of the African tectonic and magnetic features are explained in terms of this single stress system. The tensional stress fields in the crust exerted by the upwelling mantle flows are shown to be regions of structural kinship characterized by major concentration of mineral deposits. It is probable that the space techniques are capable of detecting and determining the tectonic forces in the crust of Africa.

  19. The Pd2Si - /Pd/ - Ni - solder plated metallization system for silicon solar cells

    NASA Technical Reports Server (NTRS)

    Coleman, M. G.; Pryor, R. A.; Sparks, T. G.

    1978-01-01

    The rationale and application of a plated metal system, Pd2Si Pd - Ni - solder, is presented. This metallization system is particularly useful on shallow p-n junction solar cells. The advantages of such plated solar cell contacts are discussed. A process sequence for applying the metallization system is outlined. A specific example is presented, including chemical plating solution formulations and detailed process step descriptions. Electrical test data for solar cells metallized with the palladium-nickel-solder system are provided.

  20. Development of 241Am lung monitoring system using an imaging plate.

    PubMed

    Hirota, Masahiro; Kurihara, Osamu; Takada, Chie; Takasaki, Koji; Momose, Takumaro; Deji, Shizuhiko; Ito, Shigeki; Saze, Takuya; Nishizawa, Kunihide

    2007-07-01

    A new 241Am lung monitoring system without shielding was devised by using an imaging plate system. The Lawrence Livermore National Laboratory's realistic torso phantom containing a 241Am lung was covered by imaging plates sealed in lightproof bags. The imaging plate system displayed 241Am lung images characteristic of the lung shape of the torso phantom. The imaging plate system's lower detection limits of 14 Bq for 60 min exposure and 6 Bq for 300 min were the same levels as those of the phoswich detectors and the germanium detectors placed in shielded rooms. The imaging plate system for 60 min exposure detected about 2% of the annual limit of 740 Bq for 241Am inhalation. A lung monitoring system using imaging plates is applicable for 241Am lung monitoring.

  1. Parallel-plate fluid flow systems for bone cell stimulation.

    PubMed

    Huesa, Carmen; Helfrich, Miep H; Aspden, Richard M

    2010-04-19

    Bone responds to changes in its mechanical environment, but the mechanisms by which it does so are poorly understood. One hypothesis of mechanosensing in bone states that osteocytes can sense the flow of fluid through the canalicular system. To study this in vitro a number of fluid flow devices have been designed in which cells are placed between parallel plates in sealed chambers. Fluid flows through the chambers at controlled rates, most commonly driven by a peristaltic pump. In addition to fluid flow, high pressures have been observed in these chambers, but the effect of this on the cellular responses has generally been ignored or considered irrelevant, something challenged by recent cellular experiments using pressure only. We have, therefore, devised a system in which we can considerably reduce the pressure while maintaining the flow rate to enable study of their effects individually and in combination. As reducing pressure also reduces the risk of leaks in flow chambers, our system is suitable for real-time microscopical experiments. We present details of the new systems and of experiments with osteoblasts to illustrate the effects of fluid flow with and without additional pressure on the translocation of beta-catenin to the nucleus.

  2. A Novel Fixation System for Acetabular Quadrilateral Plate Fracture: A Comparative Biomechanical Study

    PubMed Central

    Zha, Guo-Chun; Sun, Jun-Ying; Dong, Sheng-Jie; Zhang, Wen; Luo, Zong-Ping

    2015-01-01

    This study aims to assess the biomechanical properties of a novel fixation system (named AFRIF) and to compare it with other five different fixation techniques for quadrilateral plate fractures. This in vitro biomechanical experiment has shown that the multidirectional titanium fixation (MTF) and pelvic brim long screws fixation (PBSF) provided the strongest fixation for quadrilateral plate fracture; the better biomechanical performance of the AFRIF compared with the T-shaped plate fixation (TPF), L-shaped plate fixation (LPF), and H-shaped plate fixation (HPF); AFRIF gives reasonable stability of treatment for quadrilateral plate fracture and may offer a better solution for comminuted quadrilateral plate fractures or free floating medial wall fracture and be reliable in preventing protrusion of femoral head. PMID:25802849

  3. Relative motions of the Australian, Pacific and Antarctic plates estimated by the Global Positioning System

    NASA Technical Reports Server (NTRS)

    Larson, Kristine M.; Freymueller, Jeff

    1995-01-01

    Global Positioning System (GPS) measurements spanning approximately 3 years have been used to determine velocities for 7 sites on the Australian, Pacific and Antarctic plates. The site velocities agree with both plate model predictions and other space geodetic techniques. We find no evidence for internal deformation of the interior of the Australian plate. Wellington, New Zealand, located in the Australian-Pacific plate boundary zone, moves 20 +/- 5 mm/yr west-southwest relative to the Australian plate. Its velocity lies midway between the predicted velocities of the two plates. Relative Euler vectors for the Australia-Antarctica and Pacific-Antarctica plates agree within one standard deviation with the NUVEL-1A predictions.

  4. Plate Motion and Crustal Deformation Estimated with Geodetic Data from the Global Positioning System

    NASA Technical Reports Server (NTRS)

    Argus, Donald F.; Heflin, Michael B.

    1995-01-01

    We use geodetic data taken over four years with the Global Positioning System (GPS) to estimate: (1) motion between six major plates and (2) motion relative to these plates of ten sites in plate boundary zones. The degree of consistency between geodetic velocities and rigid plates requires the (one-dimensional) standard errors in horizontal velocities to be approx. 2 mm/yr. Each of the 15 angular velocities describing motion between plate pairs that we estimate with GPS differs insignificantly from the corresponding angular velocity in global plate motion model NUVEL-1A, which averages motion over the past 3 m.y. The motion of the Pacific plate relative to both the Eurasian and North American plates is observed to be faster than predicted by NUVEL-1A, supporting the inference from Very Long B ase- line Interferometry (VLBI) that motion of the Pacific plate has speed up over the past few m.y. The Eurasia-North America pole of rotation is estimated to be north of NUVEL-1A, consistent with the independent hypothesis that the pole has recently migrated northward across northeast Asia to near the Lena River delta. Victoria, which lies above the main thrust at the Cascadia subduction zone, moves relative to the interior of the overriding plate at 30% of the velocity of the subducting plate, reinforcing the conclusion that the thrust there is locked beneath the continental shelf and slope.

  5. Soluble penicillin-binding protein 2a: beta-lactam binding and inhibition by non-beta-lactams using a 96-well format.

    PubMed

    Toney, J H; Hammond, G G; Leiting, B; Pryor, K D; Wu, J K; Cuca, G C; Pompliano, D L

    1998-01-01

    High level methicillin resistance in Staphylococcus aureus is dependent upon the acquisition of the mecA gene encoding penicillin-binding protein 2a (PBP2a). PBP2a is a member of a family of peptidoglycan biosynthetic enzymes involved in assembly of the cell wall in bacteria and is poorly inactivated by beta-lactam antibiotics. We describe a 96-well-filter binding assay using recombinant, soluble PBP2a which allows for kinetic measurement of penicillin binding. The deacylation rate constant for the PBP2a-penicillin G covalent complex was found to be 5.7 +/- 1.0 x 10(-5) s-1 at 30 degrees C (half-life of approximately 200 min). For the PBP2a acylation reaction, the value of K(m) (penicillin G) = 0.5 +/- 0.1 mM and kcat = 1 x 10(-3) s-1, which yields a second-order rate constant (kcat/K(m)) for inactivation of 2.0 M-1 s-1. Using this assay, several non-beta-lactam inhibitors including Cibacron blue have been found which exhibit IC50 values between 10 and 30 microM. The binding affinities of several carbapenems and beta-lactams correlated well between the filter binding assay described in this report and an electrophoretic assay for PBP2a using membranes prepared form methicillin-resistant S. aureus. PMID:9448849

  6. Surface dynamics as part of the European Plate Observing System

    NASA Astrophysics Data System (ADS)

    Ludden, John

    2010-05-01

    The European Plate Observing System proposal includes a "surface dynamics" part to its objectives. EPOS will create and integrate "Dedicated observatories for multidisciplinary local data acquisition (volcanoes, in-situ fault-zone monitoring experiments, geothermal and deep drilling experiments, including the application of geophysics to Earth's surface dynamics and environmental changes)". As geologists and geophysicists we have a good idea how to measure ground motions related to earth quakes, volcanoes, landslides etc. We also know that through integration of these measurements in large arrays we gain resolution and general background information that allows a much better understanding of ground motion, rates of deformation and the driving forces. How can these geophysical measurements be applied to other environmental geoscience problems? What sorts of observations might one include in EPOS? Surface dynamic processes that can be measured by geophysical techniques include permafrost changes, coastline retreat, catchment morphology, post-glacial ice rebound, groundwater variation etc.. Some of these processes are driven by factors inherent to the deep Earth (lithosphere, mantle) interaction with surface processes (erosion, climate, sea level) which control the development of topography and are the focus of the TopoEurope project an ILP and an ESF-sponsored multidisciplinary research addresses within EPOS. Others processes are driven by climate change, population dynamics and people living on and interacting with the Earth's surface and subsurface. Where should the EPOS role focus? When do these problems become global in impact? When does geological engineering become a focus for EPOS - should it? The aim of this paper is to stimulate discussion on how surface dynamics should be integrated into EPOS.

  7. The Demonstrator for the European Plate Observing System (EPOS)

    NASA Astrophysics Data System (ADS)

    Hoffmann, T. L.; Euteneuer, F.; Ulbricht, D.; Lauterjung, J.; Bailo, D.; Jeffery, K. G.

    2014-12-01

    An important outcome of the 4-year Preparatory Phase of the ESFRI project European Plate Observing System (EPOS) was the development and first implementation of the EPOS Demonstrator by the project's ICT Working Group 7. The Demonstrator implements the vertical integration of the three-layer architectural scheme for EPOS, connecting the Integrated Core Services (ICS), Thematic Core Services (TCS) and the National Research Infrastructures (NRI). The demonstrator provides a single GUI with central key discovery and query functionalities, based on already existing services by the seismic, geologic and geodetic communities. More specifically the seismic services of the Demonstrator utilize webservices and APIs for data and discovery of raw seismic data (FDSN webservices by the EIDA Network), events (Geoportal by EMSC) and analytical data products (e.g., hazard maps by EFEHR via OGC WMS). For geologic services, the EPOS Demonstrator accesses OneGeology Europe which serves the community with geologic maps and point information via OGC webservices. The Demonstrator also provides access to raw geodetic data via a newly developed universal tool called GSAC. The Demonstrator itself resembles the future Integrated Core Service (ICS) and provides direct access to the end user. Its core functionality lies in a metadata catalogue, which serves as the central information hub and stores information about all RIs, related persons, projects, financial background and technical access information. The database schema of the catalogue is based on CERIF, which has been slightly adapted. Currently, the portal provides basic query functions as well as cross domain search. [www.epos.cineca.it

  8. Risk factors for breakage of biodegradable plate systems after bilateral sagittal split mandibular setback surgery.

    PubMed

    Yoshioka, Izumi; Igawa, Kaori; Nagata, Jyunko; Yoshida, Maho; Baba, Takashi; Ichiki, Takeshi; Kondoh, Yudai; Takamori, Koichi; Kashima, Koji; Sakoda, Sumio

    2013-06-01

    The aim of this retrospective study was to evaluate the risk factors associated with breakage of biodegradable plate systems after bilateral sagittal split mandibular setback. We studied 169 Japanese adults (62 men, 107 women; age range 16-53 years) with deformities of the jaw diagnosed as mandibular prognathism. All patients were treated by bilateral sagittal split osteotomy (BSSO) with 2 biodegradable fixation plates and screws at the anterior mandibular ramus. We collected the following data from the medical records and radiological findings: sex; age; degree of setback; presence of asymmetry; presence of open bite; operation; design of the plate; operating time; and blood loss. Multiple logistic regression analysis was used to find the factors that were independently associated with the dependent variable: breakage of the biodegradable plate system. In 10 of the 169 patients (6%) the biodegradable plate system for the BSSO broke. Factors that influenced whether or not the biodegradable plate system fractured were if they were asymmetrical (odds ratio (OR) 5.35; P=0.02) and had an open bite (OR 5.20; P=0.02). Asymmetry or open bite was significantly associated with breaks in the biodegradable plate system. Biodegradable plates should be used only when loading is minimal.

  9. Multi-well sample plate cover penetration system

    DOEpatents

    Beer, Neil Reginald

    2011-12-27

    An apparatus for penetrating a cover over a multi-well sample plate containing at least one individual sample well includes a cutting head, a cutter extending from the cutting head, and a robot. The cutting head is connected to the robot wherein the robot moves the cutting head and cutter so that the cutter penetrates the cover over the multi-well sample plate providing access to the individual sample well. When the cutting head is moved downward the foil is pierced by the cutter that splits, opens, and folds the foil inward toward the well. The well is then open for sample aspiration but has been protected from cross contamination.

  10. Transverse and torsional complex vibration systems for ultrasonic seam welding of metal plates

    PubMed

    Tsujino; Ueoka; Kashino; Sugahara

    2000-03-01

    Transverse and torsional complex vibration systems for ultrasonic seam welding of metal plate specimens, using a 27 kHz complex vibration disk welding tip vibrating in transverse and torsional vibration modes, were studied. Using a complex vibration welding system with a welding tip vibrating in elliptical or circular locus, thick plate specimens can be welded with a more uniform and larger area compared to a conventional ultrasonic welding system. The disk welding tip vibrates in an elliptical or circular locus. The complex vibration system can continuously weld multiple parts of metal plate specimens such as heat sinks with a large number of fins.

  11. Facile preparation of glycoprotein-imprinted 96-well microplates for enzyme-linked immunosorbent assay by boronate affinity-based oriented surface imprinting.

    PubMed

    Bi, Xiaodong; Liu, Zhen

    2014-01-01

    Molecularly imprinted polymers (MIPs), as inexpensive and stable substitutes of antibodies, have shown great promise in immunoassays. Glycoproteins are of significant diagnostic value. To facilitate the application of MIPs in clinical diagnostics, a general and facile imprinting method toward glycoproteins oriented for an enzyme-linked immunosorbent assay (ELISA) in the form of a 96-well microplate is essential but has not been fully explored yet. In this study, a new method called boronate affinity-based oriented surface imprinting was proposed for facile preparation of glycoprotein-imprinted microplates. A template glycoprotein was first immobilized by a boronic acid-modified microplate through boronate affinity binding, and then, a thin layer of polyaniline was formed to cover the microplate surface via in-water self-copolymerization. After the template was removed by an acidic solution, 3D cavities that can rebind the template were fabricated on the microplate surface. Using horseradish peroxidase (HRP) as a model target, the effects of imprinting conditions as well as the properties and performance of the prepared MIPs were investigated. α-Fetoprotein (AFP)-imprinted microplate was then prepared, and thereby, a MIP-based ELISA method was established. The prepared MIPs exhibited several highly favorable features, including excellent specificity, widely applicable binding pH, superb tolerance for interference, high binding strength, fast equilibrium kinetics, and reusability. The MIP-based ELISA method was finally applied to the analysis of AFP in human serum. The result was in good agreement with that by radioimmunoassay, showing a promising prospect of the proposed method in clinical diagnostics.

  12. The Core Services of the European Plate Observing System (EPOS)

    NASA Astrophysics Data System (ADS)

    Hoffmann, T. L.; Euteneuer, F. H.; Lauterjung, J.

    2013-12-01

    The ESFRI project European Plate Observing System (EPOS) was launched in November 2010 and has now completed its year 3 of the four-year preparatory phase. EPOS will create a single sustainable, permanent observation infrastructure, integrating existing geophysical monitoring networks, local observatories and experimental laboratories in Europe and adjacent regions. EPOS' technical Work Package 6 has developed a three layer architectural model for the construction of the EPOS Core Services (CS) during the subsequent implementation phase. The Poster will present and detail on these three layers, consisting of the EPOS Integrated Core Services (ICS), the Thematic Core Services (TCS) and the existing National Research Infrastructures & Data Centers. The basic layer of the architecture is established by the National Research Infrastructures (RIs) & Data Centers, which generate data and information and are responsible for the operation of the instrumentation. National RIs will provide their data to the Thematic Cores Services. The Thematic Core Services constitute the community layer of EPOS architecture and they will: 1) consist of existing (e.g. ORFEUS, EMSC), developing (e.g. EUREF/GNSS) or still to be developed Service Providers for specific thematic communities, as represented within EPOS through the technical EPOS Working Groups (e.g., seismology, volcanology, geodesy, geology, analytic labs for rock physics, geomagnetism, geo-resources ... and many others), 2) provide data services to specific communities, 3) link the National Research Infrastructures to the EPOS Integrated Services, 4) include Service Providers (e.g. OneGeology+, Intermagnet) that may be merely linked or partially integrated and 5) consist of Integrated Laboratories and RIs spanning multiple EPOS disciplines and taking advantage of other existing Thematic Services. The EPOS Integrated Services constitute the ICT layer of the EPOS portal and they will: 1) provide access to multidisciplinary data

  13. 76 FR 60531 - National Institute of Justice Interview Room Recording Systems and License Plate Readers Workshop

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-29

    ... From the Federal Register Online via the Government Publishing Office ] DEPARTMENT OF JUSTICE Office of Justice Programs National Institute of Justice Interview Room Recording Systems and License Plate Readers Workshop AGENCY: National Institute of Justice. ACTION: Notice of the Interview...

  14. Semi-automatic ground truth generation for license plate recognition system

    NASA Astrophysics Data System (ADS)

    Wang, Shen-Zheng; Zhao, San-Lung; Chen, Yi-Yuan; Lan, Kung-Ming

    2011-09-01

    License plate recognition (LPR) system is to help alert relevant personnel of any passing vehicle in the surveillance area. In order to test algorithms for license plate recognition, it is necessary to have input frames in which the ground truth is determined. The purpose of ground truth data is here to provide an absolute reference for performance evaluation or training purposes. However, annotating ground truth data for real-life inputs is very disturbing task because of timeconsuming manual. In this paper, we proposed a method of semi-automatic ground truth generation for license plate recognition in video sequences. The method started from region of interesting detection to rapidly extract characters lines followed by a license plate recognition system to verify the license plate regions and recognized the numbers. On the top of the LPR system, we incorporated a tracking-validation mechanism to detect the time interval of passing vehicles in input sequences. The tracking mechanism is initialized by a single license plate region in one frame. Moreover, in order to tolerate the variation of the license plate appearances in the input sequences, the validator would be updated by capturing positive and negatives samples during tracking. Experimental results show that the proposed method can achieve promising results.

  15. An Apple 2 based image digitizing system for use with immunoelectrophoresis plates

    NASA Astrophysics Data System (ADS)

    Pritchard, T. E.; Bateman, J. E.; Flesher, A. C.

    In order to undertake basic image analysis on 2-dimensional immunoelectrophoresis plates an image digitizing system was constructed using a 48K Apple II in conjunction with a Microworks DS-65 Digisector card which takes the video signal from a television camera in a specially constructed projection box. Accuracy and reproducibility are assured by averaging up to 16 scans and normalizing to a blank plate. Careful packing of the data permits the processing of a plate on a single Apple disk while the primary disk drive carries the system software. The plate image of 70 mm by 70 mm is digitized into an array of 128 by 128 pixels each with 64 intensity levels.

  16. Lengthening over nails using the double plate system ONAS-DPS

    PubMed Central

    Antolič, Vane

    2016-01-01

    Stable insertion of large Schanz screws behind an intramedullary (IM) nail when lengthening over nails (LON) may be difficult due to the limited bone stock. Additionally, the highly probable contact between the screws and IM nail (which is difficult to avoid) increases the likelihood of infection spreading from the skin via Schanz screws directly to the IM nail. A new device for LON has been developed. Instead of inserting Schanz screws from the external fixator beside the IM nail (as in standard LON), a system of two overlaying plates was constructed. Schanz screws can be fixed to the plates without entering the bone. The plates are fixed to the bone using four angle stability screws. The holes in the plates offer stabile fixation for a chosen angle under which the screw is positioned through the cortical bone. Using the new system there is no need to place Schanz screws behind the IM nail. Instead, Schanz screws pass to the plate and not through the bone. The new system for elongation over IM nail is called “Over Nail Angle Stability-Double Plate System” (ONAS-DPS) [Antolič V (2013) Modular side device with an intramedullary nail for guiding a bone during its lengthening. World Intellectual Property Organization. International Publication number: WO 2013/176632 A1]. PMID:27163094

  17. Vibration characteristics of a cantilever plate with attached spring-mass system

    NASA Astrophysics Data System (ADS)

    Chiba, M.; Sugimoto, T.

    2003-02-01

    Coupled free vibration analysis has been performed on a cantilever thin plate carrying a spring-mass system attached on an arbitrary point by using Rayleigh-Ritz method. Influence of an attached 'spring-mass' system, i.e., attached position, relative values of mass and spring constant, on the coupled vibration characteristics of the system has been clarified comparing with those of uncoupled ones. Optimal attached position to maximize coupled plate natural frequency is also investigated and shown in contour diagrams. The influence of an attached mass has also been investigated, as the limiting case whereby the spring stiffness of the 'spring-mass' system approaches infinity.

  18. Evaluation of the Minnesota Easy Culture System II Bi-Plate and Tri-Plate for identification of common mastitis pathogens in milk.

    PubMed

    Royster, E; Godden, S; Goulart, D; Dahlke, A; Rapnicki, P; Timmerman, J

    2014-01-01

    The objective of this study was to validate use of the Minnesota Easy Culture System II Bi-Plate and Tri-Plate (University of Minnesota Laboratory for Udder Health, St. Paul) to identify common mastitis pathogens in milk. A total of 283 quarter and composite milk samples submitted to the University of Minnesota Laboratory for Udder Health during the spring of 2010 were cultured simultaneously using 3 methods: standard laboratory culture (reference method) and the Minnesota Easy Culture System II Bi-Plate and Tri-Plate methods. Bi-Plate and Tri-Plate cultures were incubated for 18 to 24h and interpreted by 2 independent, untrained readers within 5h of each other. An experienced technician completed the standard laboratory culture. For each sample, all 3 study personnel recorded the culture result (yes/no) for each of the following diagnostic categories: no bacterial growth (NG), mixed (2 organisms), contaminated (3 or more organisms), gram-positive (GP), gram-negative (GN), Staphylococcus spp., Streptococcus spp., Streptococcus agalactiae, Streptococcus dysgalactiae, Streptococcus uberis, Enterococcus spp., Staphylococcus aureus, coagulase-negative staphylococci, Escherichia coli, Klebsiella spp., and other. For each category, the prevalence, sensitivity, specificity, accuracy, and predictive values of a positive and negative test were calculated, and the agreement between readers and between each reader and the laboratory was assessed. Specificity, overall accuracy, and negative predictive values were generally high (>80%) for the Bi-Plate and Tri-Plate for each category. Sensitivity and positive predictive values were intermediate (>60%) or high (>80%) for the broad categories of NG, GP, GN, Staphylococcus spp. and Streptococcus spp., and for Staph. aureus, but were generally lower (<60%) for other more specific categories. Similarly, interreader agreement (kappa value) was moderate to substantial (40-80%) for the broad categories of NG, GP, GN, Staphylococcus spp

  19. Evaluation of the Minnesota Easy Culture System II Bi-Plate and Tri-Plate for identification of common mastitis pathogens in milk.

    PubMed

    Royster, E; Godden, S; Goulart, D; Dahlke, A; Rapnicki, P; Timmerman, J

    2014-01-01

    The objective of this study was to validate use of the Minnesota Easy Culture System II Bi-Plate and Tri-Plate (University of Minnesota Laboratory for Udder Health, St. Paul) to identify common mastitis pathogens in milk. A total of 283 quarter and composite milk samples submitted to the University of Minnesota Laboratory for Udder Health during the spring of 2010 were cultured simultaneously using 3 methods: standard laboratory culture (reference method) and the Minnesota Easy Culture System II Bi-Plate and Tri-Plate methods. Bi-Plate and Tri-Plate cultures were incubated for 18 to 24h and interpreted by 2 independent, untrained readers within 5h of each other. An experienced technician completed the standard laboratory culture. For each sample, all 3 study personnel recorded the culture result (yes/no) for each of the following diagnostic categories: no bacterial growth (NG), mixed (2 organisms), contaminated (3 or more organisms), gram-positive (GP), gram-negative (GN), Staphylococcus spp., Streptococcus spp., Streptococcus agalactiae, Streptococcus dysgalactiae, Streptococcus uberis, Enterococcus spp., Staphylococcus aureus, coagulase-negative staphylococci, Escherichia coli, Klebsiella spp., and other. For each category, the prevalence, sensitivity, specificity, accuracy, and predictive values of a positive and negative test were calculated, and the agreement between readers and between each reader and the laboratory was assessed. Specificity, overall accuracy, and negative predictive values were generally high (>80%) for the Bi-Plate and Tri-Plate for each category. Sensitivity and positive predictive values were intermediate (>60%) or high (>80%) for the broad categories of NG, GP, GN, Staphylococcus spp. and Streptococcus spp., and for Staph. aureus, but were generally lower (<60%) for other more specific categories. Similarly, interreader agreement (kappa value) was moderate to substantial (40-80%) for the broad categories of NG, GP, GN, Staphylococcus spp

  20. Preliminary Experience With A Charged Selenium Plate Projection X-Ray System

    NASA Astrophysics Data System (ADS)

    Papin, Patrick J.; Mankovich, Nicholas J.; Barbaric, Zoran; Huang, H. K.

    1984-06-01

    Electrostatic imaging techniques provide the means to record x-ray images without the use of film. The conventional screen-film photon receptor is replaced by a charged selenium-oxide plate. After exposure, the plate is scanned with multiple electrometer probes forming a 1024x1024x12 bit digital image from the latent electrostatic image. This imaging modality represents an early entry into the era of true digital radiography, evolving toward a filmless diagnostic imaging facility. This paper discusses the architecture of an experimental charged selenium plate projection digital x-ray system. As well as some preliminary results of the characteristics of a amorphous selenium plate photon receptor exposed to visible light.

  1. Evaluation of a force plate system for measuring center of pressure in railroad ballast.

    PubMed

    Xu, Hang; Merryweather, Andrew; Bloswick, Donald

    2016-05-01

    Traditional biomechanical analyses have focused primarily on the human gait across hard, flat surfaces and provide little information about human locomotion as a function of work environment or terrain. The purpose of this study was evaluation of a force plate system for measure of center of pressure (COP) in railroad ballast by comparing its accuracy across three surface conditions (hard surface, mainline ballast and walking ballast) with two configurations (level and 7° cross-slope). Custom walkways and an isolation fixture were developed to rigidly attach a force plate beneath ballast surfaces to collect the COP. The difference in COP location (ΔCOPx, y, z) between the force plate system and a calibration system (motion capture derived) were compared using repeated-measures analysis of variance. Results indicate that the effects of surface condition and configuration were not significant for ΔCOPx, y, z and no differences were found among the three surface conditions during pairwise comparison, though ΔCOPx, y, z were different between the center and corners of the force plate in ballasts for both level and cross-slope configurations. The system presented in this study demonstrates the feasibility of measuring the COP by using an isolation-fixture force plate to expand the scope of biomechanical studies on ballast surfaces that are level or cross-slope. PMID:27131198

  2. Oscillations of a spring-magnet system damped by a conductive plate

    NASA Astrophysics Data System (ADS)

    Ladera, C. L.; Donoso, G.

    2013-09-01

    We study the motion of a spring-magnet system that oscillates with very low frequencies above a circular horizontal non-magnetizable conductive plate. The magnet oscillations couple with the plate via the Foucault currents induced therein. We develop a simple theoretical model for this magneto-mechanical oscillator, a model that leads to the equation of a damped harmonic oscillator, whose weak attenuation constant depends upon the system parameters, e.g. the electrical conductivity of the constituent material of the plate and its thickness. We present a set of validating experiments, the results of which are predicted with good accuracy by our analytical model. Additional experiments can be performed with this oscillating system or its variants. This oscillator is simple and low-cost, easy to assemble, and can be used in experiments or project works in physics teaching laboratories at the undergraduate level.

  3. Sensitivity Characteristics Of A Prototype Selenium Plate Detection System For Digital Radiographic Imaging

    NASA Astrophysics Data System (ADS)

    Papin, Patrick J.; Mankovich, Nicholas J.; Huang, H. K.

    1985-06-01

    We present an X ray measurement methodology with some preliminary X ray sensitivity characteristics for a prototype digital radiography system using amorphous selenium as the primary image receptor. As an imaging modality this experimental electrostatic system has the potential to replace film in existing general diagnostic radiography procedures. The imaging plate consists of a 360 micron layer of amorphous selenium deposited on an aluminumoxide substrate. An initial plate charge of 1400 volts (3.9 volts per micron) was exposed to X ray spectra produced with 50, 70, and 90 kVp with total filtration of 3 mm aluminum and 9 cm lucite. After this exposure the plate was scanned by a bank of electrometer probes at a distance of 100 microns. Sensitometric comparisons were then made to a conventional calcium-tungstate film-screen combination. The sensiometric response of the system is shown to be linear with an almost four fold increase in exposure latitude.

  4. Proceedings of the Flat-Plate Solar Array Project Research Forum on Photovoltaic Metallization Systems

    NASA Technical Reports Server (NTRS)

    1983-01-01

    A photovoltaic Metallization Research forum, under the sponsorship of the Flat-Plate Solar Array Project consisted of five sessions, covering: (1) the current status of metallization systems, (2) system design, (3) thick-film metallization, (4) advanced techniques, and (5) future metallization challenges.

  5. Concentration field in an ordered system of reacting plates situated along a flow

    NASA Astrophysics Data System (ADS)

    Polianin, A. D.; Sergeev, Iu. A.

    1981-02-01

    The plane problem of convective diffusion in an ordered semiinfinite system of plates situated along the flow of an ideal fluid is examined. Changes of the concentration field are determined primarily by the interaction of diffusion wakes and boundary layers of the plates, situated one after the other along the flow. Equations describing the concentration distribution on the outer boundary of the boundary layer of each plate are obtained and analyzed. It is shown that the concentration distribution in the core of the flow is described by a Volterra equation with an integrable singularity. The successive approximation method is used to determine the asymptotic properties of the concentration field some distance from the inlet to the system.

  6. Flate-plate photovoltaic power systems handbook for Federal agencies

    NASA Technical Reports Server (NTRS)

    Cochrane, E. H.; Lawson, A. C.; Savage, C. H.

    1984-01-01

    The primary purpose is to provide a tool for personnel in Federal agencies to evaluate the viability of potential photovoltaic applications. A second objective is to provide descriptions of various photovoltaic systems installed by different Federal agencies under the Federal Photovoltaic Utilization Program so that other agencies may consider similar applications. A third objective is to share lessons learned to enable more effective procurement, design, installation, and operation of future photovoltaic systems. The intent is not to provide a complete handbook, but rather to provide a guide for Federal agency personnel with additional information incorporated by references. The steps to be followed in selecting, procuring, and installing a photovoltaic application are given.

  7. VAPI: low-cost, rapid automated visual inspection system for Petri plate analysis

    NASA Astrophysics Data System (ADS)

    Chatburn, L. T.; Kirkup, B. C.; Polz, M. F.

    2007-09-01

    Most culture-based microbiology tasks utilize a petri plate during processing, but rarely do the scientists capture the full information available from the plate. In particular, visual analysis of plates is an under-developed rich source of data that can be rapid and non-invasive. However, collecting this data has been limited by the difficulties of standardizing and quantifying human observations, by the limits of a scientists' fatigue, and by the cost of automating the process. The availability of specialized counting equipment and intelligent camera systems has not changed this - they are prohibitively expensive for many laboratories, only process a limited number of plate types, are often destructive to the sample, and have limited accuracy. This paper describes an automated visual inspection solution, VAPI, that employs inexpensive consumer computing hardware and digital cameras along with custom cross-platform open-source software written in C++, combining Trolltech's Qt GUI toolkit with Intel's OpenCV computer vision library. The system is more accurate than common commercial systems costing many times as much, while being flexible in use and offering comparable responsiveness. VAPI not only counts colonies but also sorts and enumerates colonies by morphology, tracks colony growth by time series analysis, and provides other analytical resources. Output to XML files or directly to a database provides data that can be easily maintained and manipulated by the end user, offering ready access for system enhancement, interaction with other software systems, and rapid development of advanced analysis applications.

  8. A vision-based material tracking system for heavy plate rolling mills

    NASA Astrophysics Data System (ADS)

    Tratnig, Mark; Reisinger, Johann; Hlobil, Helmut

    2007-01-01

    A modern heavy plate rolling mill can process more than 20 slabs and plates simultaneously. To avoid material confusions during a compact occupancy and the permanent discharging and re-entering of parts, one must know the identity and position of each part at every moment. One possibility to determine the identity and position of each slab and plate is the application of a comprehensive visual-based tracking system. Compared to a tracking system that calculates the position of a plate based on the diameter and the turns of the transport rolls, a visual system is not corrupted by a position- and material dependent transmission slip. In this paper we therefore present a vision-based material tracking system for the 2-dimensional tracking of glowing material in harsh environment. It covers the production area from the plant's descaler to the pre-stand of the rolling mill and consists of four independent, synchronized overlapping cameras. The paper first presents the conceptual design of the tracking system - and continues then with the camera calibration, the determination of pixel contours, the data segmentation and the fitting & modelling of the objects bodies. In a next step, the work will then show the testing setup. It will be described how the material tracking system was implemented into the control system of the rolling mill and how the delivered tracking data was checked on its correctness. Finally, the paper presents some results. It will be shown that the position of some moving plates was estimated with a precision of approx. 0.5m. The results will be analyzed and it will be explained where the inaccuracies come from and how they eventually can be removed. The paper ends with a conclusion and an outlook on future work.

  9. Control design and robustness analysis of a ball and plate system by using polynomial chaos

    SciTech Connect

    Colón, Diego; Balthazar, José M.; Reis, Célia A. dos; Bueno, Átila M.; Diniz, Ivando S.; Rosa, Suelia de S. R. F.

    2014-12-10

    In this paper, we present a mathematical model of a ball and plate system, a control law and analyze its robustness properties by using the polynomial chaos method. The ball rolls without slipping. There is an auxiliary robot vision system that determines the bodies' positions and velocities, and is used for control purposes. The actuators are to orthogonal DC motors, that changes the plate's angles with the ground. The model is a extension of the ball and beam system and is highly nonlinear. The system is decoupled in two independent equations for coordinates x and y. Finally, the resulting nonlinear closed loop systems are analyzed by the polynomial chaos methodology, which considers that some system parameters are random variables, and generates statistical data that can be used in the robustness analysis.

  10. Control design and robustness analysis of a ball and plate system by using polynomial chaos

    NASA Astrophysics Data System (ADS)

    Colón, Diego; Balthazar, José M.; dos Reis, Célia A.; Bueno, Átila M.; Diniz, Ivando S.; de S. R. F. Rosa, Suelia

    2014-12-01

    In this paper, we present a mathematical model of a ball and plate system, a control law and analyze its robustness properties by using the polynomial chaos method. The ball rolls without slipping. There is an auxiliary robot vision system that determines the bodies' positions and velocities, and is used for control purposes. The actuators are to orthogonal DC motors, that changes the plate's angles with the ground. The model is a extension of the ball and beam system and is highly nonlinear. The system is decoupled in two independent equations for coordinates x and y. Finally, the resulting nonlinear closed loop systems are analyzed by the polynomial chaos methodology, which considers that some system parameters are random variables, and generates statistical data that can be used in the robustness analysis.

  11. 78 FR 59065 - Interview Room Recording System Standard and License Plate Reader Standard Workshops

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-25

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF JUSTICE Office of Justice Programs Interview Room Recording System Standard and License Plate Reader Standard Workshops AGENCY: National Institute of Justice, Department of Justice. ACTION: Notice of the Interview...

  12. Present-day plate motions: Retrieval from the TOPEX/Poseidon orbitography network (DORIS system)

    NASA Technical Reports Server (NTRS)

    Souriau, Annie; Cazenave, Anny; Biancale, R.; Balmino, G.; Dominh, K.; Mazzega, P.; Lemoine, J.-M.; Boucher, Claude; Willis, P.; Kasser, M.

    1991-01-01

    The goal of the proposal is to determine the present motion of the main tectonic plates from the Doppler data of the Doppler Orbitography and Radiopositioning Integrated by Satellite (DORIS) orbitography system, which includes in its final configuration about 50 tracking stations with a world-wide distribution.

  13. A high resolution resistive plate chamber tracking system developed for cosmic ray muon tomography

    NASA Astrophysics Data System (ADS)

    Baesso, P.; Cussans, D.; Thomay, C.; Velthuis, J. J.; Burns, J.; Steer, C.; Quillin, S.

    2013-08-01

    This work describes the performance of a muon tracker built with high resolution glass resistive plate chambers. The tracker is the result of a collaboration between University of Bristol and the Atomic Weapon Establishment to develop a reliable and cost effective system to scan shipping containers in search of special nuclear materials. The current setup consists of 12 detection layers, each comprised of a resistive plate chamber read out by 1.5 mm pitch strips. For most of the layers we achieved an efficiency better than 95%, a purity above 95% and a signal-to-noise ratio better than 300. A spatial resolution better than 500μm was obtained for most layers, thus satisfying the main requirements to apply resistive plate chambers to cosmic ray tomography.

  14. Plate coil thermal test bench for the Daniel K. Inouye Solar Telescope (DKIST) carousel cooling system

    NASA Astrophysics Data System (ADS)

    Phelps, LeEllen; Murga, Gaizka; Montijo, Guillermo; Hauth, David

    2014-08-01

    Analyses have shown that even a white-painted enclosure requires active exterior skin-cooling systems to mitigate dome seeing which is driven by thermal nonuniformities that change the refractive index of the air. For the Daniel K. Inouye Solar Telescope (DKIST) Enclosure, this active surface temperature control will take the form of a system of water cooled plate coils integrated into the enclosure cladding system. The main objective of this system is to maintain the surface temperature of the enclosure as close as possible to, but always below, local ambient temperature in order to mitigate this effect. The results of analyses using a multi-layer cladding temperature model were applied to predict the behavior of the plate coil cladding system and ultimately, with safety margins incorporated into the resulting design thermal loads, the detailed designs. Construction drawings and specifications have been produced. Based on these designs and prior to procurement of the system components, a test system was constructed in order to measure actual system behavior. The data collected during seasonal test runs at the DKIST construction site on Haleakalā are used to validate and/or refine the design models and construction documents as appropriate. The test fixture was also used to compare competing hardware, software, components, control strategies, and configurations. This paper outlines the design, construction, test protocols, and results obtained of the plate coil thermal test bench for the DKIST carousel cooling system.

  15. Measurements of Conversion Efficiency for a Flat Plate Thermophotovoltaic System Using a Photonic Cavity Test System

    SciTech Connect

    E.J. Brown; C.T. Ballinger; S.R. Burger; G.W. Charache; L.R. Danielson; D.M. DePoy; T.J. Donovan; M. LoCascio

    2000-05-30

    The performance of a 1 cm{sup 2} thermophotovoltaic (TPV) module was recently measured in a photonic cavity test system. A conversion efficiency of 11.7% was measured at a radiator temperature of 1076 C and a module temperature of 29.9 C. This experiment achieved the highest direct measurement of efficiency for an integrated TPV system. Efficiency was calculated from the ratio of the peak (load matched) electrical power output and the heat absorption rate. Measurements of these two parameters were made simultaneously to assure the validity of the measured efficiency value. This test was conducted in a photonic cavity which mimicked a typical flat-plate TPV system. The radiator was a large, flat graphite surface. The module was affixed to the top of a copper pedestal for heat absorption measurements. The heat absorption rate was proportional to the axial temperature gradient in the pedestal under steady-state conditions. The test was run in a vacuum to eliminate conductive and convective heat transfer mechanisms. The photonic cavity provides the optimal test environment for TPV efficiency measurements because it incorporates all important physical phenomena found in an integrated TPV system: high radiator emissivity and blackbody spectral shape, photon recycling, Lambertian distribution of incident radiation and complex geometric effects. Furthermore, the large aspect ratio between radiating surface area and radiator/module spacing produces a view factor approaching unity with minimal photon leakage.

  16. Proceedings of the flat-plate solar array project research forum on photovoltaic metallization systems

    SciTech Connect

    1983-11-15

    A Photovoltaic Metallization Research Forum, under the sponsorship of the Jet Propulsion Laboratory's Flat-Plate Solar Array Project and the US Department of Energy, was held March 16-18, 1983 at Pine Mountain, Georgia. The Forum consisted of five sessions, covering (1) the current status of metallization systems, (2) system design, (3) thick-film metallization, (4) advanced techniques and (5) future metallization challenges. Twenty-three papers were presented.

  17. Optimum design of bipolar plates for separate air flow cooling system of PEM fuel cells stacks

    NASA Astrophysics Data System (ADS)

    Franco, Alessandro

    2015-12-01

    The paper discusses about thermal management of PEM fuel cells. The objective is to define criteria and guidelines for the design of the air flow cooling system of fuel cells stacks for different combination of power density, bipolar plates material, air flow rate, operating temperature It is shown that the optimization of the geometry of the channel permits interesting margins for maintaining the use of separate air flow cooling systems for high power density PEM fuel cells.

  18. High-throughput flow injection analysis mass spectroscopy with networked delivery of color-rendered results. 2. Three-dimensional spectral mapping of 96-well combinatorial chemistry racks.

    PubMed

    Görlach, E; Richmond, R; Lewis, I

    1998-08-01

    For the last two years, the mass spectroscopy section of the Novartis Pharma Research Core Technology group has analyzed tens of thousands of multiple parallel synthesis samples from the Novartis Pharma Combinatorial Chemistry program, using an in-house developed automated high-throughput flow injection analysis electrospray ionization mass spectroscopy system. The electrospray spectra of these samples reflect the many structures present after the cleavage step from the solid support. The overall success of the sequential synthesis is mirrored in the purity of the expected end product, but the partial success of individual synthesis steps is evident in the impurities in the mass spectrum. However this latter reaction information, which is of considerable utility to the combinatorial chemist, is effectively hidden from view by the very large number of analyzed samples. This information is now revealed at the workbench of the combinatorial chemist by a novel three-dimensional display of each rack's complete mass spectral ion current using the in-house RackViewer Visual Basic application. Colorization of "forbidden loss" and "forbidden gas-adduct" zones, normalization to expected monoisotopic molecular weight, colorization of ionization intensity, and sorting by row or column were used in combination to highlight systematic patterns in the mass spectroscopy data.

  19. Cerenkov and cyclotron Cerenkov instabilities in a dielectric loaded parallel plate waveguide sheet electron beam system

    SciTech Connect

    Zhao Ding; Ding Yaogen

    2011-09-15

    A dielectric loaded parallel plate waveguide sheet electron beam system can be taken as a reliable model for the practical dielectric loaded rectangular waveguide sheet beam system that has a transverse cross section with a large width to height ratio. By using kinetic theory, the dispersion equations for Cerenkov and cyclotron Cerenkov instabilities in the parallel plate waveguide sheet beam system have been obtained rigorously. The dependences of the growth rate of both instabilities on the electric and structural parameters have also been investigated in detail through numerical calculations. It is worthwhile to point out that adopting an electron beam with transverse velocity can evidently improve the growth rate of Cerenkov instability, which seems like the case of cyclotron Cerenkov instability.

  20. Managing Vancouver B1 fractures by cerclage system compared to locking plate fixation - a biomechanical study.

    PubMed

    Gordon, Katharina; Winkler, Martin; Hofstädter, Thomas; Dorn, Ulrich; Augat, Peter

    2016-06-01

    With increasing life expectancy and number of total hip arthroplasties (THA), the need for revision surgery is increasing too. The aim of this study was to evaluate the optimal fracture treatment for a clinically characteristic Vancouver B1 fracture. We hypothesized that locking plate fixation has biomechanical advantages over fixation with a simple cerclage system. Additionally, we hypothesized that removal of the primary short stem and revision with a long stem would show biomechanical benefit. The biomechanical testing was performed with a static and a dynamic loading protocol on twenty 4th Generation sawbones. These were divided into four different groups (n = 5 each). In group 1, the primary uncemented short stem remained and the fracture was stabilized with a locking plate. In group 2, the primary stem remained and the fracture was stabilized with a cerclage stabilization system containing two stabilizers and four cerclages. In group 3, the primary stem was replaced by an uncemented long revision stem and the fracture was fixed with a locking plate. In group 4, the short stem was replaced by a long revision stem and the fracture was fixed with the cerclage system. Static testing revealed that the revision of the short stem with the long stem caused a 2-fold (p < 0.001, ANOVA) increase of axial stiffness. In dynamic testing, the number of cycles to failure was 4 times (p < 0.001, ANOVA) higher with the long revision stem. Compared to locked plating cerclage wiring demonstrated a 26% more cycles to failure (p = 0.031, ANOVA). The load to failure was 91% larger (p < 0.001, ANOVA) with the long revision stem and 11% smaller with locked plating (p < 0.001, ANOVA). In conclusion, the present biomechanical study indicates that periprosthetic Vancouver B1 fractures can be sufficiently fixed by simple cerclage systems. Revision with a long replacement stem provides a superior mechanical stability regardless of type of osteosynthesis fixation and is therefore a viable

  1. Development of Portable Automatic Number Plate Recognition System on Android Mobile Phone

    NASA Astrophysics Data System (ADS)

    Mutholib, Abdul; Gunawan, Teddy S.; Chebil, Jalel; Kartiwi, Mira

    2013-12-01

    The Automatic Number Plate Recognition (ANPR) System has performed as the main role in various access control and security, such as: tracking of stolen vehicles, traffic violations (speed trap) and parking management system. In this paper, the portable ANPR implemented on android mobile phone is presented. The main challenges in mobile application are including higher coding efficiency, reduced computational complexity, and improved flexibility. Significance efforts are being explored to find suitable and adaptive algorithm for implementation of ANPR on mobile phone. ANPR system for mobile phone need to be optimize due to its limited CPU and memory resources, its ability for geo-tagging image captured using GPS coordinates and its ability to access online database to store the vehicle's information. In this paper, the design of portable ANPR on android mobile phone will be described as follows. First, the graphical user interface (GUI) for capturing image using built-in camera was developed to acquire vehicle plate number in Malaysia. Second, the preprocessing of raw image was done using contrast enhancement. Next, character segmentation using fixed pitch and an optical character recognition (OCR) using neural network were utilized to extract texts and numbers. Both character segmentation and OCR were using Tesseract library from Google Inc. The proposed portable ANPR algorithm was implemented and simulated using Android SDK on a computer. Based on the experimental results, the proposed system can effectively recognize the license plate number at 90.86%. The required processing time to recognize a license plate is only 2 seconds on average. The result is consider good in comparison with the results obtained from previous system that was processed in a desktop PC with the range of result from 91.59% to 98% recognition rate and 0.284 second to 1.5 seconds recognition time.

  2. Formation of Island Arc-Trench System due to Plate Subduction on the Basis of Elastic Dislocation Theory

    NASA Astrophysics Data System (ADS)

    Fukahata, Y.; Matsu'ura, M.

    2015-12-01

    The most conspicuous cumulative deformation in subduction zones is the formation of island arc-trench system. A pair of anomalies in topography and free-air gravity, high in the arc and low around the trench, is observed without exceptions all over the world. Since the 1960s, elastic dislocation theory has been widely used to interpret coseismic crustal deformation. For the modeling of longer-term crustal deformation, it is necessary to consider viscoelastic properties of the asthenosphere. By simply applying elastic-viscoelastic dislocation theory to plate subduction, Matsu'ura and Sato (1989, GJI) have shown that some crustal deformation remains after the completion of one earthquake cycle, which means that crustal deformation accumulates with time in a long term due to plate subduction. In fact, by constructing a plate interface model in and around Japan, Hashimoto, Fukui and Matsu'ura (2004, PAGEOPH) have demonstrated that the computed vertical displacements due to steady plate subduction well explain the observed free-air gravity anomaly pattern. Recently, we got a lucid explanation of crustal deformation due to plate subduction. In subduction zones, oceanic plates bend and descend into the mantle. Because the bending of oceanic plates is usually not spontaneous, there exists kinematic interaction between the oceanic and overriding plates, which causes cumulative deformation of the overriding plate. This may be understood based on the law of action and reaction: one is bending of an oceanic plate and the other is deformation of the overriding plate. As a special case, it is useful to consider plate subduction along a part of true circle. In this case, crustal deformation due to steady subduction is solely caused by the effect of gravity, because dislocation along a circle does not cause any intrinsic internal deformation. When an oceanic plate is descending along an arcuate plate interface from the right-hand side, according to dislocation theory, the oceanic

  3. Clinical application of locked plating system in children. An orthopaedic view

    PubMed Central

    Zafra-Jimenez, Jose Alberto; Rodriguez Martin, Juan

    2010-01-01

    In recent years, the locked plating system has gained favour in the treatment of certain fractures in adults; however, there is not much information regarding its use in children. We think there could be some advantages and applications such as: an alternative to external fixation, the bridge plating technique, unicortical screws, removal of hardware, metadiaphyseal fractures, periarticular fractures, poor quality bone, and allograft fixation. However, there are some disadvantages to keep in mind and the final decision for using it should be based on the osteosynthesis method principle the surgeon would like to apply. In this review article we discuss the up-to-date possible clinical applications and issues of this system. PMID:20162415

  4. Integration of image analysis and robotics into a fully automated colony picking and plate handling system.

    PubMed Central

    Jones, P; Watson, A; Davies, M; Stubbings, S

    1992-01-01

    We describe here the integration of image analysis and robotics to produce a fully automated colony picking/plate handling system. Biological tests were performed to verify its performance in terms of sterilisation and accuracy of picking. The machine was then used by a single operative to pick a 36,000 clone cDNA library in approximately 42 hrs over 5 days. Images PMID:1408762

  5. Advanced Extended Plate and Beam Wall System in a Cold-Climate House

    SciTech Connect

    Mallay, Dave; Wiehagen, Joseph; Kochkin, Vladimir

    2016-01-01

    This report presents the design and evaluation of an innovative wall system. This highly insulated (high-R) light-frame wall system for use above grade in residential buildings is referred to as Extended Plate & Beam (EP&B). The EP&B design is the first of its kind to be featured in a new construction test house (NCTH) for the DOE Building America program. The EP&B wall design integrates standard building methods and common building products to construct a high-R wall that minimizes transition risks and costs to builders.

  6. Development of a System to Measure Recrystallization Ratio of Plate Steel Using Laser-Based Ultrasonics

    SciTech Connect

    Nagata, Y.; Yamada, H.; Hamada, N.; Lim, C. S.; Yi, J. K.; Hong, S. T.; Choi, S. G.; Oh, K. J.

    2007-03-21

    In this study, a material property measurement system of plate steel using laser-based ultrasonics has been developed. The system consists of pulsed Nd:YAG laser for ultrasonic generation, CW single frequency laser and Fabry-Perot interferometer for ultrasonic detection. The system generates and detects shear waves and precisely calculates anisotropy parameter values of shear wave velocities of test samples. At first, the relationship between anisotropy parameter and recrystallization ratio was investigated in the laboratory experiments. Quenching the test samples just after the ultrasonic measurement, recrystallization ratio values were measured by the conventional microscopic method. According to the experimental results, the anisotropy parameter values showed a good correlation with actual recrystallization ratio values. To evaluate the applicability of the system to real steel production line, the system was installed in hot rolling pilot plant of plate steel. As the results, it was demonstrated that the system could measure the recrystallization ratio using the anisotropy parameter values of shear wave velocities, even in the environment of hot rolling pilot plant.

  7. β-Cyclodextrin enhanced on-line organic solvent field-amplified sample stacking in capillary zone electrophoresis for analysis of ambroxol in human plasma, following liquid-liquid extraction in the 96-well format.

    PubMed

    Li, Ji; Bi, Youwei; Wang, Li; Sun, Fanlu; Chen, Zhao; Xu, Guili; Fan, Guorong

    2012-07-01

    A field-amplified sample stacking (FASS) and capillary zone electrophoresis (CZE) method is described for the quantification of ambroxol hydrochloride in human plasma, following liquid-liquid extraction in the 96-well format. The separation was carried out at 25 °C in a 31.2 cm × 75 μm fused-silica capillary with an applied voltage of 15 kV. The background electrolyte (BGE) was composed of 6.25 mM borate-25 mM phosphate (pH 3.0) and 1mM β-cyclodextrin. The detection wavelength was 210 nm. Clean-up and preconcentration of plasma biosamples were developed by 96-well format liquid-liquid extraction (LLE). In this study, FASS in combination with β-cyclodextrin enhanced the sensitivity about 60-70 fold in total. The method was suitably validated with respect to stability, specificity, linearity, lower limit of quantitation, accuracy, precision, extraction recovery and robustness. The calibration graph was linear for ambroxol hydrochloride from 2 to 500 ng/ml. The lower limit of quantification was 2 ng/ml. The intra- and inter-day precisions of lowest limit of quantification (LLOQ) were 9.61 and 11.80%, respectively. The method developed was successfully applied to the evaluation of clinical pharmacokinetic study of ambroxol hydrochloride tablet after oral administration to 12 healthy volunteers.

  8. β-Cyclodextrin enhanced on-line organic solvent field-amplified sample stacking in capillary zone electrophoresis for analysis of ambroxol in human plasma, following liquid-liquid extraction in the 96-well format.

    PubMed

    Li, Ji; Bi, Youwei; Wang, Li; Sun, Fanlu; Chen, Zhao; Xu, Guili; Fan, Guorong

    2012-07-01

    A field-amplified sample stacking (FASS) and capillary zone electrophoresis (CZE) method is described for the quantification of ambroxol hydrochloride in human plasma, following liquid-liquid extraction in the 96-well format. The separation was carried out at 25 °C in a 31.2 cm × 75 μm fused-silica capillary with an applied voltage of 15 kV. The background electrolyte (BGE) was composed of 6.25 mM borate-25 mM phosphate (pH 3.0) and 1mM β-cyclodextrin. The detection wavelength was 210 nm. Clean-up and preconcentration of plasma biosamples were developed by 96-well format liquid-liquid extraction (LLE). In this study, FASS in combination with β-cyclodextrin enhanced the sensitivity about 60-70 fold in total. The method was suitably validated with respect to stability, specificity, linearity, lower limit of quantitation, accuracy, precision, extraction recovery and robustness. The calibration graph was linear for ambroxol hydrochloride from 2 to 500 ng/ml. The lower limit of quantification was 2 ng/ml. The intra- and inter-day precisions of lowest limit of quantification (LLOQ) were 9.61 and 11.80%, respectively. The method developed was successfully applied to the evaluation of clinical pharmacokinetic study of ambroxol hydrochloride tablet after oral administration to 12 healthy volunteers. PMID:22464560

  9. Liquid chromatography/tandem mass spectrometric bioanalysis using normal-phase columns with aqueous/organic mobile phases - a novel approach of eliminating evaporation and reconstitution steps in 96-well SPE.

    PubMed

    Naidong, Weng; Shou, Wilson Z; Addison, Thomas; Maleki, Saber; Jiang, Xiangyu

    2002-01-01

    Bioanalytical methods using automated 96-well solid-phase extraction (SPE) and liquid chromatography with electrospray tandem mass spectrometry (LC/MS/MS) are widely used in the pharmaceutical industry. SPE methods typically require manual steps of drying of the eluates and reconstituting of the analytes with a suitable injection solvent possessing elution strength weaker than the mobile phase. In this study, we demonstrated a novel approach of eliminating these two steps in 96-well SPE by using normal-phase LC/MS/MS methods with low aqueous/high organic mobile phases, which consisted of 70-95% organic solvent, 5-30% water, and small amount of volatile acid or buffer. While the commonly used SPE elution solvents (i.e. acetonitrile and methanol) have stronger elution strength than a mobile phase on reversed-phase chromatography, they are weaker elution solvents than a mobile phase for normal-phase LC/MS/MS and therefore can be injected directly. Analytical methods for a range of polar pharmaceutical compounds, namely, omeprazole, metoprolol, fexofenadine, pseudoephedrine as well as rifampin and its metabolite 25-desacetyl-rifampin, in biological fluids, were developed and optimized based on the foregoing principles. As a result of the time saving, a batch of 96 samples could be processed in one hour. These bioanalytical LC/MS/MS methods were validated according to "Guidance for Industry - Bioanalytical Method Validation" recommended by the Food and Drug Administration (FDA) of the United States.

  10. Microtiter plate-based antibody microarrays for bacteria and toxins

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Research has focused on the development of rapid biosensor-based, high-throughput, and multiplexed detection of pathogenic bacteria in foods. Specifically, antibody microarrays in 96-well microtiter plates have been generated for the purpose of selective detection of Shiga toxin-producing E. coli (...

  11. Hepatocyte function within a stacked double sandwich culture plate cylindrical bioreactor for bioartificial liver system.

    PubMed

    Xia, Lei; Arooz, Talha; Zhang, Shufang; Tuo, Xiaoye; Xiao, Guangfa; Susanto, Thomas Adi Kurnia; Sundararajan, Janani; Cheng, Tianming; Kang, Yuzhan; Poh, Hee Joo; Leo, Hwa Liang; Yu, Hanry

    2012-11-01

    Bioartificial liver (BAL) system is promising as an alternative treatment for liver failure. We have developed a bioreactor with stacked sandwich culture plates for the application of BAL. This bioreactor design addresses some of the persistent problems in flat-bed bioreactors through increasing cell packing capacity, eliminating dead flow, regulating shear stress, and facilitating the scalability of the bioreactor unit. The bioreactor contained a stack of twelve double-sandwich-culture plates, allowing 100 million hepatocytes to be housed in a single cylindrical bioreactor unit (7 cm of height and 5.5 cm of inner diameter). The serial flow perfusion through the bioreactor increased cell-fluid contact area for effective mass exchange. With the optimal perfusion flow rate, shear stress was minimized to achieve high and uniform cell viabilities across different plates in the bioreactor. Our results demonstrated that hepatocytes cultured in the bioreactor could re-establish cell polarity and maintain liver-specific functions (e.g. albumin and urea synthesis, phase I&II metabolism functions) for seven days. The single bioreactor unit can be readily scaled up to house adequate number of functional hepatocytes for BAL development.

  12. PERPENDICULAR DOUBLE-PLATE FIXATION WITH LOCKING SYSTEM FOR ACROMION PEDICLE FRACTURE

    PubMed Central

    Zhu, Junkun; Pan, Zhijun; Zheng, Rongzong; Lan, Shuhua

    2016-01-01

    Objective : To describe the surgical technique and preliminary clinical outcomes in a series of open reduction internal fixation of basal acromion process fractures applying a double-plating technique. Methods : Nine consecutive patients, mean age 33.4 years old (range, 23-61 years old) with unilateral acromion fracture (Type 3 AO/OTA) with more than 1cm displacement who underwent fixation utilizing a locked double-plating technique, were evaluated on average at 7.8 months (range, 3-15 months) for outcomes related to pain, shoulder function, and surgical complications. Results : Eight patients recovered with complete radiographic union and favorable shoulder function. One case failed to be fully evaluated for more than 3 months follow-up. The overall scores of Constant, Shoulder Pain and Disability Index (SPADI) and DASH for the eight patients reviewed were 91.9± 6.31, 3.11± 3.79 and 5.2± 6.35, respectively. No post-operative infection or surgical hardware irritation was identified at final follow-up of these eight patients. Conclusion : While more evidence is needed to justify its advantages over traditional implants, perpendicular double-plate with a locking system may be indicated for acromion pedicle fracture treatment, since it performed well for fracture healing and joint function rehabilitation. Level of Evidence IV, Therapeutic Study. PMID:26981047

  13. A multichannel deflection plates control system for the ALF facility at the APS.

    SciTech Connect

    Deriy, B.; Accelerator Systems Division

    2006-01-01

    A deflection plates control system was developed as part of SPIRIT (Single Photon Ionization/Resonant Ionization to Threshold), a new secondary neutral mass spectrometry (SNMS) instrument that uses tunable vacuum ultraviolet light from the APS ALF (Argonne Linear Free-electron laser) facility for postionization. The system comprises a crate controller with PC104 embedded computer, 32 amplifiers, and two 1-kV power supplies. Thirty-two D/A converters are used to control voltages at the deflection plates within {+-} 400 V with 100-mV resolution. An algorithm for simultaneous sweeping of up to 16 XY areas with 10-{micro}s time resolution also has been implemented in the embedded computer. The purpose of the system is to supply potentials to various ion optical elements for electrostatic control of keV primary and secondary ion beams in this SNMS instrument. The control system is of particular value in supplying (1) bipolar potentials for steering ions, (2) multiple potentials for octupole lenses that shape the ion beams, and (3) ramped deflection potentials for rastering the primary ion beam. The system has been in use as part of the SPIRIT instrument at the ALF facility since 2002.

  14. Zone plate tilt study in transmission x-ray microscope system at 8-11 keV

    NASA Astrophysics Data System (ADS)

    Chao, Fu-Han; Yin, Gung-Chian; Liang, Keng S.; Lai, Yin-Chieh

    2009-08-01

    Zone plate [1] has been used as a focal lens in transmission X-ray microscope (TXM) optical system in recent decades [2, 3]. In TXM of NSRRC[4,5], the thickness of zone plate is about 900nm and the width of its out most zones is 50nm, which has a high aspect ratio 18. When zone plate is tilted, the image quality will be affected by aberration. Since the aspect ratio of zone plate is large, for incident beam, the shape of zone plate's transmission function will look different when zone plate is tilted. The both experimental and simulation result will be shown in this present. A five axes stage is designed and manufactured for the zone plate holder for three dimensional movement, tip and tilt. According to Fourier theory, we can calculate the wave distribution on image plane, if we know the original wave function, the distances between each element, and the transparencies of the sample and zone plate. A parallel simulation process code in MATLAB is developed in workstation cluster with up to 128Gbytes memory. The effects of aberration generated by tilt effect are compared from the experimental data and simulation result. A maximum tilt angle within the acceptable image quality is calculated by simulation and will be verified by experiment.

  15. Distributed Plate Boundary Deformation Across the San Andreas Fault System, Central California

    NASA Astrophysics Data System (ADS)

    Dyson, M.; Titus, S. J.; Demets, C.; Tikoff, B.

    2007-12-01

    Plate boundaries are now recognized as broad zones of complex deformation as opposed to narrow zones with discrete offsets. When assessing how plate boundary deformation is accommodated, both spatially and temporally, it is therefore crucial to understand the relative contribution of the discrete and distributed components of deformation. The creeping segment of the San Andreas fault is an ideal location to study the distribution of plate boundary deformation for several reasons. First, the geometry of the fault system in central California is relatively simple. Plate motion is dominated by slip along the relatively linear strike-slip San Andreas fault, but also includes lesser slip along the adjacent and parallel Hosgri-San Gregorio and Rinconada faults, as well as within the borderlands between the three fault strands. Second, the aseismic character of the San Andreas fault in this region allows for the application of modern geodetic techniques to assess creep rates along the fault and across the region. Third, geologic structures within the borderlands are relatively well-preserved allowing comparison between modern and ancient rates and styles of deformation. Continuous GPS stations, alignment arrays surveys, and other geodetic methods demonstrate that approximately 5 mm/yr of distributed slip is accumulated (on top of the fault slip rate) across a 70-100 km wide region centered on the San Andreas fault. New campaign GPS data also suggest 2-5 mm/yr of deformation in the borderlands. These rates depend on the magnitude of the coseismic and postseismic corrections that must be made to our GPS time series to compensate for the 2003 San Simeon and 2004 Parkfield earthquakes, which rupture faults outside, but near the edges of our GPS network. The off-fault deformation pattern can be compared to the style of permanent deformation recorded in the geologic record. Fold and thrust belts in the borderlands are better developed in the Tertiary sedimentary rocks west of

  16. Enrichment of circulating tumor cells using a centrifugal affinity plate system.

    PubMed

    Lee, Sung-Woo; Hyun, Kyung-A; Kim, Seung-Il; Kang, Ji-Yoon; Jung, Hyo-Il

    2014-12-19

    Circulating tumor cells (CTCs) are defined as cells that have detached from a primary tumor and are circulating in the bloodstream. Their isolation and quantification is of great value for cancer prognoses and drug testing. Here, the development of a centrifugal affinity plate (CAP) system is described, in which centrifugal force and antibody-based capture are exploited to enrich CTCs on one plate and hematological cells on the other. The CAP is rotated to exert centrifugal force on the cells in a blood sample, quickly transporting them to the anti-epithelial adhesion molecule (EpCAM)-coated and anti-CD45-coated surface of the CAP to shorten the reaction time and increase the adhesion force between the tumor and blood cells and each antibody. The effect of a rotating process on cell capture was investigated, and the capture efficiency was demonstrated using blood samples from healthy donors spiked with human non-small cell lung cancer (NCI-H1650) and breast cancer (MCF-7) cells. The CAP system was capable of rapid isolation and identification of CTCs without the requirement for pretreatment of blood samples. Finally, the CAP system was tested to evaluate the detection efficiency of CTCs in the blood samples of breast cancer patients. The number of captured CTCs in only 1ml of blood varied from 6 to 10.

  17. Cooled electronic system with liquid-cooled cold plate and thermal spreader coupled to electronic component

    DOEpatents

    Chainer, Timothy J.; Graybill, David P.; Iyengar, Madhusudan K.; Kamath, Vinod; Kochuparambil, Bejoy J.; Schmidt, Roger R.; Steinke, Mark E.

    2016-04-05

    Apparatus and method are provided for facilitating cooling of an electronic component. The apparatus includes a liquid-cooled cold plate and a thermal spreader associated with the cold plate. The cold plate includes multiple coolant-carrying channel sections extending within the cold plate, and a thermal conduction surface with a larger surface area than a surface area of the component to be cooled. The thermal spreader includes one or more heat pipes including multiple heat pipe sections. One or more heat pipe sections are partially aligned to a first region of the cold plate, that is, where aligned to the surface to be cooled, and partially aligned to a second region of the cold plate, which is outside the first region. The one or more heat pipes facilitate distribution of heat from the electronic component to coolant-carrying channel sections of the cold plate located in the second region of the cold plate.

  18. Cooled electronic system with liquid-cooled cold plate and thermal spreader coupled to electronic component

    DOEpatents

    Chainer, Timothy J.; Graybill, David P.; Iyengar, Madhusudan K.; Kamath, Vinod; Kochuparambil, Bejoy J.; Schmidt, Roger R.; Steinke, Mark E.

    2016-08-09

    Apparatus and method are provided for facilitating cooling of an electronic component. The apparatus includes a liquid-cooled cold plate and a thermal spreader associated with the cold plate. The cold plate includes multiple coolant-carrying channel sections extending within the cold plate, and a thermal conduction surface with a larger surface area than a surface area of the component to be cooled. The thermal spreader includes one or more heat pipes including multiple heat pipe sections. One or more heat pipe sections are partially aligned to a first region of the cold plate, that is, where aligned to the surface to be cooled, and partially aligned to a second region of the cold plate, which is outside the first region. The one or more heat pipes facilitate distribution of heat from the electronic component to coolant-carrying channel sections of the cold plate located in the second region of the cold plate.

  19. Systematic analysis of in vitro cell rolling using a multi-well plate microfluidic system.

    PubMed

    Levy, Oren; Anandakumaran, Priya; Ngai, Jessica; Karnik, Rohit; Karp, Jeffrey M

    2013-10-16

    A major challenge for cell-based therapy is the inability to systemically target a large quantity of viable cells with high efficiency to tissues of interest following intravenous or intraarterial infusion. Consequently, increasing cell homing is currently studied as a strategy to improve cell therapy. Cell rolling on the vascular endothelium is an important step in the process of cell homing and can be probed in-vitro using a parallel plate flow chamber (PPFC). However, this is an extremely tedious, low throughput assay, with poorly controlled flow conditions. Instead, we used a multi-well plate microfluidic system that enables study of cellular rolling properties in a higher throughput under precisely controlled, physiologically relevant shear flow. In this paper, we show how the rolling properties of HL-60 (human promyelocytic leukemia) cells on P- and E-selectin-coated surfaces as well as on cell monolayer-coated surfaces can be readily examined. To better simulate inflammatory conditions, the microfluidic channel surface was coated with endothelial cells (ECs), which were then activated with tumor necrosis factor-α (TNF-α), significantly increasing interactions with HL-60 cells under dynamic conditions. The enhanced throughput and integrated multi-parameter software analysis platform, that permits rapid analysis of parameters such as rolling velocities and rolling path, are important advantages for assessing cell rolling properties in-vitro. Allowing rapid and accurate analysis of engineering approaches designed to impact cell rolling and homing, this platform may help advance exogenous cell-based therapy.

  20. Flat-plate boiloff calorimeters for testing of thermal insulation systems

    NASA Astrophysics Data System (ADS)

    Fesmire, J. E.; Johnson, W. L.; Kelly, A. O.; Meneghelli, B. J.; Swanger, A. M.

    2015-12-01

    Cryostats have been developed and standardized for laboratory testing of thermal insulation systems in a flat-plate configuration. Boiloff calorimetry is the measurement principle for determining the effective thermal conductivity (ke) and heat flux (q) of test specimens under a wide range of actual conditions. Cryostat-500 is thermally guarded to measure absolute thermal performance when calibrated with a known reference via an adjustable-edge guard ring. With liquid nitrogen as the energy meter, the cold boundary temperature can be adjusted to any temperature between 77 K and approximately 300 K by the interposition of a thermal resistance layer between the cold mass and the specimen. A low thermal conductivity suspension system has compliance rods that adjust for specimen thickness and compression force. Material type, thickness, density, flatness, compliance, outgassing, and temperature sensor placement are important test considerations, and edge effects and calibration techniques for the apparatus are crucial. Over the full vacuum pressure range, the thermal performance capability is nearly four orders of magnitude. The horizontal configuration provides key advantages over the vertical cylindrical cryostats for testing at ambient pressure conditions. Cryostat-500’s design and test methods, other flat-plate boiloff calorimeters, and results for select thermal insulation materials (composites, foams, aerogels) are discussed.

  1. A plate-driven model for enigmatic volcanic history of the Cascades-Yellowstone System

    NASA Astrophysics Data System (ADS)

    Szwaja, S.; Kincaid, C. R.; Druken, K. A.; MacDougall, J.

    2013-12-01

    The Cascades subduction system in the Pacific Northwest (USA) represents a complex tectonic setting, where rollback subduction of the Juan de Fuca plate beneath the North American plate, back-arc extension, and a possible mantle plume have been proposed to explain the complicated volcanic trends observed over the past 20 Ma. Plume and non-plume models have been developed to reconcile the voluminous Columbia River/Steens Flood Basalts (CSFB) (~20 Ma), the age progressive (15 Ma to present) Snake River Plain (SRP) that terminates at Yellowstone and the opposite, or westward trending High Lava Plains (HLP) volcanic track of eastern/central Oregon. We present results from laboratory experiments designed to test a plate-driven model for reproducing gross spatial-temporal characteristics of these three magmatic features. Models use a glucose fluid with temperature dependent viscosity in representing Earth's mantle and continuous rubber belts that kinematically reproduce subduction trends for the Cascades system. Experiments begin at 20 Ma with a volume of mantle residuum in the Cascades wedge that is elongated and restricted in the trench-parallel and trench-normal directions, respectively. The underlying assumption is that residuum was created in the wedge during an earlier plate steepening event that caused the flood basalts. Our models characterize dispersion patterns for the melt residuum material as it deforms within four-dimensional wedge circulation fields driven by rollback subduction (e.g. with a translational component of motion). Results show that residuum viscosity, relative to the ambient fluid, determines whether anomalous fluid can evolve to a morphology that matches the SRP/HLP tracks over ~15-20Ma. A weak residuum (e.g. retained partial melt) deforms over this time scale from the initial north-south oriented feature to an east-west trending morphology that is thin in both depth and north-south extent, material initially beneath CSFB is offset to the

  2. On performance of an oscillating plate underwater propulsion system with variable chordwise flexibility at different depths of submergence

    NASA Astrophysics Data System (ADS)

    Barannyk, Oleksandr; Buckham, Bradley J.; Oshkai, Peter

    2012-01-01

    In this work, an oscillating plate propulsor undergoing a combination of heave translation and pitch rotation is investigated experimentally. The oscillation kinematics are inspired by swimming mechanisms employed by fish and other marine animals. The primary focus was on the propulsive characteristics of such oscillating plates, which were studied by means of direct force measurements in the thrust-producing regime. Experiments were performed at constant Reynolds number and constant heave amplitude. By varying the Strouhal number, the depth of submergence and the chordwise flexibility of the plate, it was possible to investigate corresponding changes in the generated thrust and the hydromechanical efficiency. It was possible to establish a set of parameters, including the driving frequency of the system, the ratio of rigid to flexible segment length of the plate, and the range of Strouhal numbers that led to an overall increase in thrust and efficiency. The experiments, involving plates with various ratios of rigid to flexible segment lengths, showed that greater flexibility increased the propulsive efficiency and thrust compared to an identical motion of the purely rigid plate. By submerging the plate at different depths, it was observed that the proximity of the propulsor to the bottom of the channel led to an overall increase in the thrust coefficient across the oscillation frequencies considered. The flow visualization revealed the formation of large dynamic stall vortices that influenced the wake structure, and suggested that their constructive interaction with trailing edge vortices might lead to overall improvement of thrust and efficiency.

  3. Stand-alone flat-plate photovoltaic power systems: System sizing and life-cycle costing methodology for Federal agencies

    NASA Technical Reports Server (NTRS)

    Borden, C. S.; Volkmer, K.; Cochrane, E. H.; Lawson, A. C.

    1984-01-01

    A simple methodology to estimate photovoltaic system size and life-cycle costs in stand-alone applications is presented. It is designed to assist engineers at Government agencies in determining the feasibility of using small stand-alone photovoltaic systems to supply ac or dc power to the load. Photovoltaic system design considerations are presented as well as the equations for sizing the flat-plate array and the battery storage to meet the required load. Cost effectiveness of a candidate photovoltaic system is based on comparison with the life-cycle cost of alternative systems. Examples of alternative systems addressed are batteries, diesel generators, the utility grid, and other renewable energy systems.

  4. Compact three-dimensional head-mounted display system with Savart plate.

    PubMed

    Lee, Chang-Kun; Moon, Seokil; Lee, Seungjae; Yoo, Dongheon; Hong, Jong-Young; Lee, Byoungho

    2016-08-22

    We propose three-dimensional (3D) head-mounted display (HMD) providing multi-focal and wearable functions by using polarization-dependent optical path switching in Savart plate. The multi-focal function is implemented as micro display with high pixel density of 1666 pixels per inches is optically duplicated in longitudinal direction according to the polarization state. The combination of micro display, fast switching polarization rotator and Savart plate retains small form factor suitable for wearable function. The optical aberrations of duplicated panels are investigated by ray tracing according to both wavelength and polarization state. Astigmatism and lateral chromatic aberration of extraordinary wave are compensated by modification of the Savart plate and sub-pixel shifting method, respectively. To verify the feasibility of the proposed system, a prototype of the HMD module for monocular eye is implemented. The module has the compact size of 40 mm by 90 mm by 40 mm and the weight of 131 g with wearable function. The micro display and polarization rotator are synchronized in real-time as 30 Hz and two focal planes are formed at 640 and 900 mm away from eye box, respectively. In experiments, the prototype also provides augmented reality function by combining the optically duplicated panels with a beam splitter. The multi-focal function of the optically duplicated panels without astigmatism and color dispersion compensation is verified. When light field optimization for two additive layers is performed, perspective images are observed, and the integration of real world scene and high quality 3D images is confirmed. PMID:27557230

  5. Finite Element Analysis of a New Pedicle Screw-Plate System for Minimally Invasive Transforaminal Lumbar Interbody Fusion

    PubMed Central

    Zhou, Yue; Li, Changqing; Liu, Huan

    2015-01-01

    Purpose Minimally invasive transforaminal lumbar interbody fusion (MI-TLIF) is increasingly popular for the surgical treatment of degenerative lumbar disc diseases. The constructs intended for segmental stability are varied in MI-TLIF. We adopted finite element (FE) analysis to compare the stability after different construct fixations using interbody cage with posterior pedicle screw-rod or pedicle screw-plate instrumentation system. Methods A L3–S1 FE model was modified to simulate decompression and fusion at L4–L5 segment. Fixation modes included unilateral plate (UP), unilateral rod (UR), bilateral plate (BP), bilateral rod (BR) and UP+UR fixation. The inferior surface of the S1 vertebra remained immobilized throughout the load simulation, and a bending moment of 7.5 Nm with 400N pre-load was applied on the L3 vertebra to recreate flexion, extension, lateral bending, and axial rotation. Range of motion (ROM) and Von Mises stress were evaluated for intact and instrumentation models in all loading planes. Results All reconstructive conditions displayed decreased motion at L4–L5. The pedicle screw-plate system offered equal ROM to pedicle screw-rod system in unilateral or bilateral fixation modes respectively. Pedicle screw stresses for plate system were 2.2 times greater than those for rod system in left lateral bending under unilateral fixation. Stresses for plate were 3.1 times greater than those for rod in right axial rotation under bilateral fixation. Stresses on intervertebral graft for plate system were similar to rod system in unilateral and bilateral fixation modes respectively. Increased ROM and posterior instrumentation stresses were observed in all loading modes with unilateral fixation compared with bilateral fixation in both systems. Conclusions Transforaminal lumbar interbody fusion augmentation with pedicle screw-plate system fixation increases fusion construct stability equally to the pedicle screw-rod system. Increased posterior

  6. The role of 3D plating system in mandibular fractures: A prospective study

    PubMed Central

    Prasad, Rajendra; Thangavelu, Kavin; John, Reena

    2013-01-01

    Aim: The aim of our study was to evaluate the advantages and disadvantages of 3D plating system in the treatment of mandibular fractures. Patients and Methods: 20 mandibular fractures in 18 patients at various anatomic locations and were treated by open reduction and internal fixation using 3D plates. All patients were followed at regular intervals of 4th, 8th and 12th weeks respectively. Patients were assessed post-operatively for lingual splay and occlusal stability. The incidence of neurosensory deficit, infection, masticatory difficulty, non-union, malunion was also assessed. Results: A significant reduction in lingual splay (72.2%) and occlusal stability (72.2%) was seen. The overall complication rate was (16.6%) which included two patients who developed post-operative paresthesia of lip, three patients had infection and two cases of masticatory difficulty which later subsided by higher antibiotics and 4 weeks of MMF. No evidence of non-union, malunion was noted. Conclusion: A single 3D 2 mm miniplate with 2 mm × 8 mm screws is a reliable and an effective treatment modality for mandibular fracture. PMID:23946559

  7. Wave-plate structures, power selective optical filter devices, and optical systems using same

    SciTech Connect

    Koplow, Jeffrey P.

    2012-07-03

    In an embodiment, an optical filter device includes an input polarizer for selectively transmitting an input signal. The device includes a wave-plate structure positioned to receive the input signal, which includes first and second substantially zero-order, zero-wave plates arranged in series with and oriented at an angle relative to each other. The first and second zero-wave plates are configured to alter a polarization state of the input signal passing in a manner that depends on the power of the input signal. Each zero-wave plate includes an entry and exit wave plate each having a fast axis, with the fast axes oriented substantially perpendicular to each other. Each entry wave plate is oriented relative to a transmission axis of the input polarizer at a respective angle. An output polarizer is positioned to receive a signal output from the wave-plate structure and selectively transmits the signal based on the polarization state.

  8. Patterns of seismogenesis for giant plate-boundary earthquakes in island-arc-type subduction systems

    NASA Astrophysics Data System (ADS)

    Kirby, S. H.

    2006-12-01

    The global record of giant earthquake occurrence in subduction zones during the instrumental and historical eras is woefully short; only about 16 events with magnitudes above 8.4 are reasonably well documented since 1700. We find no examples of giant (M > 8.4) interplate thrust events and/or wide-ranging tsunamis sourced in the classic island arcs with fast backarc spreading (Bonin, Marianas, Tonga-Kermadec, Vanuatu, and South Scotia). The Sumatra-Andaman Earthquake of 2004 (SAE) ruptured a sector of the INDIA-BURMA subduction boundary and evidently had no known historical antecedents, suggesting that the return time may be many centuries to millennia and consistent with low convergence rates. Moreover, the persistence of rupture to the north in the weakly volcanic Nicobar/Andaman sector gives one pause to reflect on the assumption that island arcs, especially those with active back-arc spreading such as the Marianas, do not produce great interplate- thrust earthquakes. The Andaman/Nicobar subduction segment is an unusual island arc. Only two arc volcanoes occur between the convergent plate boundary west of the Andamans and the backarc ridge/transform system to the east. Backarc spreading in the Andaman/ Nicobar segment is unusual because the NNW spreading directions are nearly parallel to the trench/deformation-front as do the INDIA-BURMA plate motions across it. This geometry suggests that arc-normal extension, trench migration and associated slab normal motions may not mechanically decouple this subduction system. The Nicobar sector of the rupture for the 2004 event is roughly 200 km wide judging from the aftershock distribution; a distribution that persists to the east under the Nicobar Islands, suggesting that the plate-boundary dip is very shallow in that latitude range. If this is correct, then the down-dip limitation on seismogenic slip set by serpentinized forearc mantle (Hyndman et al., 2003) may not control rupture width as it apparently does for many

  9. High frequency analysis of a plate carrying a concentrated nonlinear spring-mass system

    NASA Astrophysics Data System (ADS)

    Culver, Dean; Dowell, Earl

    2016-09-01

    Examining the behavior of dynamical systems with many degrees of freedom undergoing random excitation at high frequency often requires substantial computation. These requirements are even more stringent for nonlinear systems. One approach for describing linear systems, Asymptotic Modal Analysis (AMA), has been extended to nonlinear systems in this paper. A prototypical system, namely a thin plate carrying a concentrated hardening cubic spring-mass, is explored. The study focuses on the response of three principal variables to random, frequency-bounded excitation: the displacement of the mounting location of the discrete spring-mass, the relative displacement of the discrete mass to this mounting location, and the absolute displacement of the discrete mass. The results indicate that extending AMA to nonlinear systems for input frequency bands containing a large number of modes is feasible. Several advantageous properties of nonlinear AMA are found, and an additional reduced frequency-domain modal method, Dominance-Reduced Classical Modal Analysis (DRCMA), is proposed that is intermediate in accuracy and the cost of computation between AMA and Classical Modal Analysis (CMA).

  10. Photostimulated phosphor based image plate detection system for HRVUV beamline at Indus-1 synchrotron radiation source

    NASA Astrophysics Data System (ADS)

    Haris, K.; Singh, Param Jeet; Shastri, Aparna; Sunanda, K.; Babita, K.; Rao, S. V. N. Bhaskara; Ahmad, Shabbir; Tauheed, A.

    2014-12-01

    A high resolution vacuum ultraviolet (HRVUV) beamline based on a 6.65 m off-plane Eagle spectrometer is in operation at the Indus-1 synchrotron radiation source, RRCAT, Indore, India. To facilitate position sensitive detection and fast spectral recording, a new BaFBr:Eu2+ phosphor based image plate (IP) detection system interchangeable with the existing photomultiplier (PMT) scanning system has been installed on this beamline. VUV photoabsorption studies on Xe, O2, N2O and SO2 are carried out to evaluate the performance of the IP detection system. An FWHM of ~0.5 Å is achieved for the Xe atomic line at 1469.6 Å. Reproducibility of spectra is found to be within the experimental resolution. Compared to the PMT scanning system, the IP shows several advantages in terms of sensitivity, recording time and S/N ratio, which are highlighted in the paper. This is the first report of incorporation of an IP detection system in a VUV beamline using synchrotron radiation. Commissioning of the new detection system is expected to greatly enhance the utilization of the HRVUV beamline as a number of spectroscopic experiments which require fast recording times combined with a good signal to noise ratio are now feasible.

  11. Mantle flow geometry from ridge to trench beneath the Gorda-Juan de Fuca plate system

    NASA Astrophysics Data System (ADS)

    Martin-Short, Robert; Allen, Richard M.; Bastow, Ian D.; Totten, Eoghan; Richards, Mark A.

    2015-12-01

    Tectonic plates are underlain by a low-viscosity mantle layer, the asthenosphere. Asthenospheric flow may be induced by the overriding plate or by deeper mantle convection. Shear strain due to this flow can be inferred using the directional dependence of seismic wave speeds--seismic anisotropy. However, isolation of asthenospheric signals is challenging; most seismometers are located on continents, whose complex structure influences the seismic waves en route to the surface. The Cascadia Initiative, an offshore seismometer deployment in the US Pacific Northwest, offers the opportunity to analyse seismic data recorded on simpler oceanic lithosphere. Here we use measurements of seismic anisotropy across the Juan de Fuca and Gorda plates to reconstruct patterns of asthenospheric mantle shear flow from the Juan de Fuca mid-ocean ridge to the Cascadia subduction zone trench. We find that the direction of fastest seismic wave motion rotates with increasing distance from the mid-ocean ridge to become aligned with the direction of motion of the Juan de Fuca Plate, implying that this plate influences mantle flow. In contrast, asthenospheric mantle flow beneath the Gorda Plate does not align with Gorda Plate motion and instead aligns with the neighbouring Pacific Plate motion. These results show that asthenospheric flow beneath the small, slow-moving Gorda Plate is controlled largely by advection due to the much larger, faster-moving Pacific Plate.

  12. Constraints on Pacific plate kinematics and dynamics with global positioning system measurements

    NASA Technical Reports Server (NTRS)

    Dixon, T. H.; Golombek, M. P.; Thornton, C. L.

    1985-01-01

    A measurement program designed to investigate kinematic and dynamic aspects of plate tectonics in the Pacific region by means of satellite observations is proposed. Accuracy studies are summarized showing that for short baselines (less than 100 km), the measuring accuracy of global positioning system (GPS) receivers can be in the centimeter range. For longer baselines, uncertainty in the orbital ephemerides of the GPS satellites could be a major source of error. Simultaneous observations at widely (about 300 km) separated fiducial stations over the Pacific region, should permit an accuracy in the centimeter range for baselines of up to several thousand kilometers. The optimum performance level is based on the assumption of that fiducial baselines are known a priori to the centimeter range. An example fiducial network for a GPS study of the South Pacific region is described.

  13. Design study of multi-imaging plate system for BNCT irradiation field at Kyoto university reactor.

    PubMed

    Tanaka, Kenichi; Sakurai, Yoshinori; Kajimoto, Tsuyoshi; Tanaka, Hiroki; Takata, Takushi; Endo, Satoru

    2016-09-01

    The converter configuration for a multi-imaging plate system was investigated for the application of quality assurance in the irradiation field profile for boron neutron capture therapy. This was performed by the simulation calculation using the PHITS code in the fields at the Heavy Water Neutron Irradiation Facility of Kyoto University Reactor. The converter constituents investigated were carbon for gamma rays, and polyethylene with and without LiF at varied (6)Li concentration for thermal, epithermal, and fast neutrons. Consequently, potential combinations of the converters were found for two components, gamma rays and thermal neutrons, for the standard thermal neutron mode and three components of gamma rays, epithermal neutrons, and thermal or fast neutrons, for the standard mixed or epithermal neutron modes, respectively. PMID:27423022

  14. Design study of multi-imaging plate system for BNCT irradiation field at Kyoto university reactor.

    PubMed

    Tanaka, Kenichi; Sakurai, Yoshinori; Kajimoto, Tsuyoshi; Tanaka, Hiroki; Takata, Takushi; Endo, Satoru

    2016-09-01

    The converter configuration for a multi-imaging plate system was investigated for the application of quality assurance in the irradiation field profile for boron neutron capture therapy. This was performed by the simulation calculation using the PHITS code in the fields at the Heavy Water Neutron Irradiation Facility of Kyoto University Reactor. The converter constituents investigated were carbon for gamma rays, and polyethylene with and without LiF at varied (6)Li concentration for thermal, epithermal, and fast neutrons. Consequently, potential combinations of the converters were found for two components, gamma rays and thermal neutrons, for the standard thermal neutron mode and three components of gamma rays, epithermal neutrons, and thermal or fast neutrons, for the standard mixed or epithermal neutron modes, respectively.

  15. Objective evaluation of interior trim effects on sound quality and noise reduction of a coupled plate cavity system

    NASA Astrophysics Data System (ADS)

    Egab, Laith; Wang, Xu

    2016-03-01

    In this study, the impedance mobility and psychoacoustic analysis methods are combined to develop a structural-acoustic model of a plate-cavity coupling system. The objective is to evaluate the effect of interior trim materials on sound loudness and sharpness of a plate-cavity coupling system. The impedance mobility method is applied to calculate the pressure frequency responses of the interior acoustic field for the plate-cavity coupling system. The sound pressure results calculated by the impedance mobility method are then directly used to calculate the psychoacoustic metrics using psychoacoustic analysis method. A good agreement was found between the experimental and analytical results. The results show that the interior trim has a large influence on the distribution of the sound loudness and sharpness inside the cavity in the middle and high frequency ranges.

  16. Extended Plate and Beam Wall System: Concept Investigation and Initial Evaluation

    SciTech Connect

    Wiehagen, J.; Kochkin, V.

    2015-08-01

    A new and innovative High-R wall design, referred to as the Extended Plate & Beam (EP&B), is under development. The EP&B system uniquely integrates foam sheathing insulation with wall framing such that wood structural panels are installed exterior of the foam sheathing, enabling the use of standard practices for installation of drainage plane, windows and doors, claddings, cavity insulation, and the standard exterior foam sheathing installation approach prone to damage of the foam during transportation of prefabricated wall panels. As part of the ongoing work, the EP&B wall system concept has undergone structural verification testing and has been positively vetted by a group of industry stakeholders. Having passed these initial milestone markers, the advanced wall system design has been analyzed to assess cost implications relative to other advanced wall systems, undergone design assessment to develop construction details, and has been evaluated to develop representative prescriptive requirements for the building code. This report summarizes the assessment steps conducted to-date and provides details of the concept development.

  17. Fluid-structure interaction study of the splitter plate in a TBCC exhaust system during mode transition phase

    NASA Astrophysics Data System (ADS)

    Guo, Shuai; Xu, Jinglei; Mo, Jianwei; Gu, Rui; Pang, Lina

    2015-07-01

    Splitter plate plays an important role in a turbine-based combined-cycle (TBCC) exhaust system during the mode transition phase when turbojet engine and ramjet engine operate simultaneously. Dissimilar pressure distribution on both sides of the plate has a potential origin in the aeroelastic coupling, which is an interesting topic while few research works have devoted to that aspect. To better understand the aeroelastic behavior of the plate and the corresponding dynamic flow features, an integrated fluid-structure interaction simulation is conducted under one particular operation condition during mode transition phase in the TBCC exhaust system. A finite-volume-based CFD solver FLUENT is adopted to solve the unsteady Reynolds average Navier-Stokes equations. ABAQUS, a finite-element-method-based CSD solver, is employed to compute the plate elastic deformation. A two-way interaction between the fluid and the structure is accomplished by the mesh-based parallel-code coupling interface (MpCCI) in a loosely-coupled manner. The accuracy of the coupling procedure is validated for the flutter of a flat plate in supersonic flow. Then, features of steady flow field of the TBCC exhaust system are discussed, followed by the investigation of the aeroelastic phenomenon of the splitter plate and the evolution process of the flow field pattern. Finally, performances variation of the exhaust system is obtained and discussed. The results show that the plate vibrates with decaying amplitude and reaches a dynamic stable state eventually. The thrust, lift and pitch moment of the TBCC exhaust system are increased by 0.68%, 2.82% and 5.86%, respectively, compared with the corresponding values in steady state which does not take into account the fluid-structure interaction effects. The analysis reveals the importance of considering the fluid-structure interaction effects in designing the splitter plate in the TBCC exhaust system and demonstrates the availability of the present coupled

  18. Coefficient of Variation Estimates for the Plate Boundary Fault System of California

    NASA Astrophysics Data System (ADS)

    Biasi, G. P.; Scharer, K. M.

    2015-12-01

    The number of high-quality paleoseismic records on major strike-slip faults of California has increased in recent years to the point that patterns in earthquake recurrence are emerging. The degree of predictability in time intervals between ground-rupturing earthquakes can be measured by the CoV (coefficient of variation). The CoV approximately normalizes for mean recurrence, and is thus useful to isolate the temporal variability of earthquake records. CoV estimates are themselves uncertain because input dates are actually probability distributions and because paleoseismic records are short and not necessarily representative samples from the underlying recurrence distribution. Radiocarbon dating uncertainty can be incorporated by sampling from event PDFs and compiling sample CoV estimates. Uncertainty due to the brevity of the site event record is larger, and neglect of it can lead to improbable estimates. Long records are now available on the San Andreas and San Jacinto faults in Southern California, and the San Andreas and Hayward faults in northern California. These faults accommodate most of the Pacific-North American relative plate motion in their respective regions. CoV estimates from sites with 8 or more events cluster around 0.63, but are as low as 0.4 for the southern Hayward fault. Sites with fewer events give similar estimates, though with lower resolution. The one prominent outlier, Burro Flats, with a CoV near 1.0, is in a region of severe fault complexity and rapid fault-normal compression. Quasi-periodic recurrence is emerging as a general property for these plate boundary faults. Some individual site records allow that, at low probabilities, recurrence could be random in time. When the ensemble is considered together, however, it is improbable that we would see the observed degree of agreement among boundary fault paleoseismic records; the more likely explanation is that quasi-periodic recurrence is a real property of the boundary fault system.

  19. An improved plating process

    NASA Technical Reports Server (NTRS)

    Askew, John C.

    1994-01-01

    An alternative to the immersion process for the electrodeposition of chromium from aqueous solutions on the inside diameter (ID) of long tubes is described. The Vessel Plating Process eliminates the need for deep processing tanks, large volumes of solutions, and associated safety and environmental concerns. Vessel Plating allows the process to be monitored and controlled by computer thus increasing reliability, flexibility and quality. Elimination of the trivalent chromium accumulation normally associated with ID plating is intrinsic to the Vessel Plating Process. The construction and operation of a prototype Vessel Plating Facility with emphasis on materials of construction, engineered and operational safety and a unique system for rinse water recovery are described.

  20. Plate motion

    SciTech Connect

    Gordon, R.G. )

    1991-01-01

    The motion of tectonic plates on the earth is characterized in a critical review of U.S. research from the period 1987-1990. Topics addressed include the NUVEL-1 global model of current plate motions, diffuse plate boundaries and the oceanic lithosphere, the relation between plate motions and distributed deformations, accelerations and the steadiness of plate motions, the distribution of current Pacific-North America motion across western North America and its margin, plate reconstructions and their uncertainties, hotspots, and plate dynamics. A comprehensive bibliography is provided. 126 refs.

  1. EVALUATION OF FLAT-PLATE PHOTOVOLTAIC THERMAL HYBRID SYSTEMS FOR SOLAR ENERGY UTILIZATION.

    SciTech Connect

    ANDREWS,J.W.

    1981-06-01

    The technical and economic attractiveness of combined photovoltaic/thermal (PV/T) solar energy collectors was evaluated. The study was limited to flat-plate collectors since concentrating photovoltaic collectors require active cooling and thus are inherently PV/T collectors, the only decision being whether to use the thermal energy or to dump it. it was also specified at the outset that reduction in required roof area was not to be used as an argument for combining the collection of thermal and electrical energy into one module. Three tests of economic viability were identified, all of which PV/T must pass if it is to be considered a promising alternative: PV/T must prove to be competitive with photovoltaic-only, thermal-only, and side-by-side photovoltaic-plus-thermal collectors and systems. These three tests were applied to systems using low-temperature (unglazed) collectors and to systems using medium-temperature (glazed) collectors in Los Angeles, New York, and Tampa. For photovoltaics, the 1986 DOE cost goals were assumed to have been realized, and for thermal energy collection two technologies were considered: a current technology based on metal and glass, and a future technology based on thin-film plastics. The study showed that for medium-temperature applications PV/T is not an attractive option in any of the locations studied. For low-temperature applications, PV/T appears to be marginally attractive.

  2. Validation and application of a liquid chromatography-tandem mass spectrometric method for the determination of GDC-0834 and its metabolite in human plasma using semi-automated 96-well protein precipitation.

    PubMed

    Shin, Young G; Jones, Steve A; Murakami, Stan C; Liu, Lichuan; Wong, Harvey; Buonarati, Michael H; Hop, Cornelis E C A

    2012-11-01

    A liquid chromatographic-tandem mass spectrometric (LC-MS/MS) method was developed and validated for the determination of GDC-0834 and its amide hydrolysis metabolite (M1) in human plasma to support clinical development. The method consisted of semi-automated 96-well protein precipitation extraction for sample preparation and LC-MS/MS analysis in positive ion mode using TurboIonSpray® for analysis. D6-GDC-0834 and D6-M1 metabolite were used as internal standards. A linear regression (weighted 1/concentration(2) ) was used to fit calibration curves over the concentration range of 1 - 500 ng/mL for both GDC-0834 and M1 metabolite. The accuracy (percentage bias) at the lower limit of quantitation (LLOQ) was 5.20 and 0.100% for GDC-0834 and M1 metabolite, respectively. The precision (CV) for samples at the LLOQ was 3.13-8.84 and 5.20-8.93% for GDC-0834 and M1 metabolite, respectively. For quality control samples at 3, 200 and 400 ng/mL, the between-run CV was ≤ 7.38% for GDC-0834 and ≤ 8.20% for M1 metabolite. Between run percentage bias ranged from -2.76 to 6.98% for GDC-0834 and from -6.73 to 2.21% for M1 metabolite. GDC-0834 and M1 metabolite were stable in human plasma for 31 days at -20 and -70°C. This method was successfully applied to support a GDC-0834 human pharmacokinetic-based study.

  3. Lameness scoring system for dairy cows using force plates and artificial intelligence.

    PubMed

    Ghotoorlar, S Mokaram; Ghamsari, S Mehdi; Nowrouzian, I; Ghotoorlar, S Mokaram; Ghidary, S Shiry

    2012-02-01

    Lameness scoring is a routine procedure in dairy industry to screen the herds for new cases of lameness. Subjective lameness scoring, which is the most popular lameness detection and screening method in dairy herds, has several limitations. They include low intra-observer and inter-observer agreement and the discrete nature of the scores which limits its usage in monitoring the lameness. The aim of this study is to develop an automated lameness scoring system comparable with conventional subjective lameness scoring by means of artificial neural networks. The system is composed of four balanced force plates installed in a hoof-trimming box. A group of 105 dairy cows was used for the study. Twenty-three features extracted from ground reaction force (GRF) data were used in a computer training process which was performed on 60 per cent of the data. The remaining 40 per cent of the data were used to test the trained system. Repeatability of the lameness scoring system was determined by GRF samples from 25 cows, captured at two different times from the same animals. The mean sd was 0.31 and the mean coefficient of variation was 14.55 per cent, which represents a high repeatability in comparison with subjective vision-based scoring methods. Although the highest sensitivity and specificity values were seen in locomotion score groups 1 and 4, the automatic lameness system was both sensitive and specific in all groups. The sensitivity and specificity were higher than 72 per cent in locomotion score groups 1 to 4, and it was 100 per cent specific and 50 per cent sensitive for group 5. PMID:22141114

  4. Continuous distributed phase-plate advances for high-energy laser systems

    NASA Astrophysics Data System (ADS)

    Marozas, J. A.; Collins, T. J. B.; Zuegel, J. D.; McKenty, P. W.; Cao, D.; Fochs, S.; Radha, P. B.

    2016-05-01

    The distributed phase plate (DPP) design code Zhizhoo’ has been used to design full- aperture, continuous near-field transmission optics for a wide variety of high-fidelity focal-spot shapes for high-energy laser systems: OMEGA EP, Dynamic Compression Sector (DCS), and the National Ignition Facility (NIF). The envelope shape, or profile, of the focal spot affects the hydrodynamics of directly driven targets in these laser systems. Controlling the envelope shape to a high degree of fidelity impacts the quality of the ablatively driven implosions. The code Zhizhoo’ not only produces DPP's with great control of the envelope shape, but also spectral and gradient control as well as robustness from near-field phase aberrations. The focal-spot shapes can take on almost any profile from symmetric to irregular patterns and with high fidelity relative to the objective function over many decades of intensity. The control over the near-field phase spectrum and phase gradients offer greater manufacturability of the full- aperture continuous surface-relief pattern. The flexibility and speed of the DPP design code Zhizhoo’ will be demonstrated by showing the wide variety of successful designs that have been made and those that are in progress.

  5. Chlorine isotope geochemistry of Icelandic thermal fluids: Implications for geothermal system behavior at divergent plate boundaries

    NASA Astrophysics Data System (ADS)

    Stefánsson, Andri; Barnes, Jaime D.

    2016-09-01

    The chlorine isotope composition of thermal fluids from Iceland were measured in order to evaluate the source of chlorine and possible chlorine isotope fractionation in geothermal systems at divergent plate boundaries. The geothermal systems studied have a wide range of reservoir temperatures from 40 to 437 °C and in-situ pH of 6.15 to 7.15. Chlorine concentrations range from 5.2 to 171 ppm and δ37 Cl values are -0.3 to + 2.1 ‰ (n = 38). The δ37 Cl values of the thermal fluids are interpreted to reflect the source of the chlorine in the fluids. Geothermal processes such as secondary mineral formation, aqueous and vapor speciation and boiling were found to have minimal effects on the δ37 Cl values. However, further work is needed on incorporation of Cl into secondary minerals and its effect on Cl isotope fractionation. Results of isotope geochemical modeling demonstrate that the range of δ37 Cl values documented in the natural thermal fluids can be explained by leaching of the basaltic rocks by meteoric source water under geothermal conditions. Magmatic gas partitioning may also contribute to the source of Cl in some cases. The range of δ37 Cl values of the fluids result mainly from the large range of δ37 Cl values observed for Icelandic basalts, which range from -0.6 to + 1.2 ‰.

  6. Clinical results of using the proximal humeral internal locking system plate for internal fixation of displaced proximal humeral fractures.

    PubMed

    Norouzi, Masoud; Naderi, Mohammad Nasir; Komasi, Mehdi Hemmati; Sharifzadeh, Seyyed Reza; Shahrezaei, Mostafa; Eajazi, Alireza

    2012-05-01

    Proximal humerus fractures are accounting for 4-5% of all fractures with increasing incidence. Proximal Humeral Internal Locking System (PHILOS) plate is a new plate which permits early mobility and lowers the risk of complications. The aim of this study was to evaluate the functional outcome and the complication rate after using this plate. Between 2006-2008, 37 patients with displaced 2-, 3-, and 4-part fractures of the proximal humerus underwent surgery using PHILOS plate. The mean range of follow-up was 12 months. Twenty patients were aged 60 years and younger, and 17 were aged older than 60 years. The average American Shoulder and Elbow Surgeons (ASES) score at the final follow-up was 77.62. According to Michener and colleagues classification, 5.4% of patients had an excellent outcome, 72.9% were minimally functionally limited, 16.2% were moderately functionally limited, and 5.4% were maximally functionally limited. The average ASES score between patients 60 years and older and those 60 years and younger was not different significantly. One patient developed avascular necrosis of the humeral head, 2 patients developed an infection, and no patients developed a nonunion. Fixation with PHILOS plate can be considered a good method with high union rates for this kind of fracture, especially in the older population with osteoporotic bone.

  7. An Expert System to Analyze Homogeneity in Fuel Element Plates for Research Reactors

    SciTech Connect

    Tolosa, S.C.; Marajofsky, A.

    2004-10-06

    In the manufacturing control of Fuel Element Plates for Research Reactors, one of the problems to be addressed is how to determine the U-density homogeneity in a fuel plate and how to obtain qualitative and quantitative information in order to establish acceptance or rejection criteria for such, as well as carrying out the quality follow-up. This paper is aimed at developing computing software which implements an Unsupervised Competitive Learning Neural Network for the acknowledgment of regions belonging to a digitalized gray scale image. This program is applied to x-ray images. These images are generated when the x-ray beams go through a fuel plate of approximately 60 cm x 8 cm x 0.1 cm thick. A Nuclear Fuel Element for Research Reactors usually consists of 18 to 22 of these plates, positioned in parallel, in an arrangement of 8 x 7 cm. Carrying out the inspection of the digitalized x-ray image, the neural network detects regions with different luminous densities corresponding to U-densities in the fuel plate. This is used in quality control to detect failures and verify acceptance criteria depending on the homogeneity of the plate. This modality of inspection is important as it allows the performance of non-destructive measurements and the automatic generation of the map of U-relative densities of the fuel plate.

  8. Cavity-Enhanced Immunoassay Measurements in Microtiter Plates Using BBCEAS.

    PubMed

    Bajuszova, Zuzana; Ali, Zulfiqur; Scott, Simon; Seetohul, L Nitin; Islam, Meez

    2016-05-17

    We report on the first detailed use of broadband cavity enhanced absorption spectroscopy (BBCEAS) as a detection system for immunoassay. A vertical R ≥ 0.99 optical cavity was integrated with a motorized XY stage, which functioned as a receptacle for 96-well microtiter plates. The custom-built cavity enhanced microplate reader was used to make measurements on a commercially available osteocalcin sandwich ELISA kit. A 30-fold increase in path length was obtained with a minimum detectable change in the absorption coefficient, αmin(t), of 5.3 × 10(-5) cm(-1) Hz(-1/2). This corresponded to a 39-fold increase in the sensitivity of measurement when directly compared to measurements in a conventional microplate reader. Separate measurements of a standard STREP-HRP colorimetric reaction in microtiter plates of differing optical quality produced an increase in sensitivity of up to 115-fold compared to a conventional microplate reader. The sensitivity of the developed setup compared favorably with previous liquid-phase cavity enhanced studies and approaches the sensitivity of typical fluorometric ELISAs. It could benefit any biochemical test which uses single pass absorption as a detection method, through either the label free detection of biologically important molecules at lower concentrations or the reduction in the amount of expensive biochemicals needed for a particular test, leading to cheaper tests. PMID:27089516

  9. International Space Station Internal Thermal Control System Cold Plate/Fluid-Stability Test: Two Year Update

    NASA Technical Reports Server (NTRS)

    Wieland, Paul; Holt, Mike; Roman, Monsi; Cole, Harold; Daugherty, Steve

    2003-01-01

    Operation of the Internal Thermal Control System (ITCS) Cold Plate/Fluid-Stability Test Facility commenced on September 5, 2000. The facility was intended to provide advance indication of potential problems on board the International Space Station (ISS) and was designed: 1) To be materially similar to the flight ITCS. 2) To allow for monitoring during operation. 3) To run continuously for three years. During the first two years of operation the conditions of the coolant and components were remarkably stable. During this same period of time, the conditions of the ISS ITCS significantly diverged from the desired state. Due to this divergence, the test facility has not been providing information useful for predicting the flight ITCS condition. Results of the first two years are compared with flight conditions over the same time period, showing the similarities and divergences. To address the divergences, the test facility was modified incrementally to more closely match the flight conditions, and to gain insight into the reasons for the divergence. Results of these incremental changes are discussed and provide insight into the development of the conditions on orbit.

  10. Injury to the anterior tibial system during percutaneous plating of a proximal tibial fracture.

    PubMed

    Gary, Joshua L; Sciadini, Marcus F

    2012-07-01

    Minimally invasive osteosynthesis of proximal tibial fractures has grown in popularity in recent years. This article describes a patient with a Schatzker type VI proximal tibial fracture (AO/OTA type 41.C3) and previous compartment syndrome treated with definitive fixation 8 weeks after initial injury with a precontoured proximal tibial plate and a distal targeting device. Brisk bleeding occurred during percutaneous insertion of a cortical screw at the midshaft of the tibia. Surgical exploration revealed sidewall tearing of the anterior tibial artery and vein, which were clipped at the screw insertion site. After the bleeding was controlled, the patient had a strong palpable posterior tibial pulse with no palpable dorsalis pedis pulse, and the foot remained well perfused. Function of the deep peroneal nerve was normal postoperatively. Previous concerns regarding the percutaneous treatment of proximal tibial fractures have focused on the risks of damage to the superficial peroneal nerve from distal screws. Based on cadaveric studies, percutaneously and laterally based screw placement in the distal tibial metaphysis threatens injury to the anterior tibial system. However, with alterations to the normal anatomy caused by severe trauma, previously described safe zones may be changed and neurovascular structures may be exposed to risk in locations that were previously thought safe. PMID:22784915

  11. Blood flow measurement system for fetoscopic laser photocoagulation of chorionic plate anastomosing vessels (FLPC).

    PubMed

    Seki, Takeshi; Oka, Kiyoshi; Naganawa, Akihiro; Yamashita, Hiromasa; Kim, Keri; Chiba, Toshio

    2009-01-01

    Fetoscopic laser photocoagulation of chorionic plate anastomosing vessels (FLPC) applies to the treatment of previable fetuses with severe twin-twin transfusion syndrome (TTTS). The ultimate goal of FLPC is selective blood flow interruption of anastomotic communicating vessels on the placenta fetoscopically. However, there has not been an established method to confirm that the blood flow is blocked, thus, it depends on the operator's experience or intuition to evaluate whether the FLPC was performed successfully or not. For this issue, we have developed a composite-type optical fiberscope (2.2 mm in diameter), which has centrally-located cautery laser fiber and surrounding located fiberglasses for viewing. This fiberscope enables transmission of 50 W Yb fiber laser which can be focused to 10 mm focal length using two lenses on the fiberscope tip. In this study, we combined the fiberscope and a laser blood-flow meter, and irradiated cautery laser to porcine mesenteric vein with measuring blood flow at the same time. From the experimental results, we could quantitatively measure the blood flow before and after laser irradiation, and confirm the blood flow blocking with our system. PMID:19929297

  12. Hypervelocity plate acceleration

    SciTech Connect

    Marsh, S.P.; Tan, T.H.

    1991-01-01

    Shock tubes have been used to accelerate 1.5-mm-thick stainless steel plates to high velocity while retaining their integrity. The fast shock tubes are 5.1-cm-diameter, 15.2-cm-long cylinders of PBX-9501 explosive containing a 1.1-cm-diameter cylindrical core of low-density polystyrene foam. The plates have been placed directly in contact with one face of the explosive system. Plane-wave detonation was initiated on the opposite face. A Mach disk was formed in the imploding styrofoam core, which provided the impulse required to accelerate the metal plate to high velocity. Parametric studies were made on this system to find the effect of varying plate metal, plate thickness, foam properties, and addition of a barrel. A maximum plate velocity of 9.0 km/s has been observed. 6 refs., 17 figs.

  13. The European Plate Observing System (EPOS) Services for Solid Earth Science

    NASA Astrophysics Data System (ADS)

    Cocco, Massimo; Atakan, Kuvvet; Pedersen, Helle; Consortium, Epos

    2016-04-01

    The European Plate Observing System (EPOS) aims to create a pan-European infrastructure for solid Earth science to support a safe and sustainable society. The main vision of the European Plate Observing System (EPOS) is to address the three basic challenges in Earth Sciences: (i) unravelling the Earth's deformational processes which are part of the Earth system evolution in time, (ii) understanding the geo-hazards and their implications to society, and (iii) contributing to the safe and sustainable use of geo-resources. The mission of EPOS is to monitor and understand the dynamic and complex Earth system by relying on new e-science opportunities and integrating diverse and advanced Research Infrastructures in Europe for solid Earth Science. EPOS will enable innovative multidisciplinary research for a better understanding of the Earth's physical and chemical processes that control earthquakes, volcanic eruptions, ground instability and tsunami as well as the processes driving tectonics and Earth's surface dynamics. EPOS will improve our ability to better manage the use of the subsurface of the Earth. Through integration of data, models and facilities EPOS will allow the Earth Science community to make a step change in developing new concepts and tools for key answers to scientific and socio-economic questions concerning geo-hazards and geo-resources as well as Earth sciences applications to the environment and to human welfare. EPOS has now started its Implementation Phase (EPOS-IP). One of the main challenges during the implementation phase is the integration of multidisciplinary data into a single e-infrastructure. Multidisciplinary data are organized and governed by the Thematic Core Services (TCS) and are driven by various scientific communities encompassing a wide spectrum of Earth science disciplines. These include Data, Data-products, Services and Software (DDSS), from seismology, near fault observatories, geodetic observations, volcano observations

  14. Biomechanics of humerus fracture fixation by locking, cortical, and hybrid plating systems in a cadaver model.

    PubMed

    Sutherland, George B; Creekmore, Tina; Mukherjee, Debi P; Ogden, Alan L; Anissian, Lucas; Marymont, John V

    2010-08-11

    The goal of this study was to discover how locking or cortical screws or a hybrid of both would perform in stabilizing a simulated humerus fracture. We simulated stripping of screw threads or poor bone quality by overdrilling the screw hole, and also studied a control group with no overdrilling. A total of 38 fresh frozen cadaver humeri were divided into 2 groups: 16 undergoing overdrilling with a drill bit 0.3 mm less than the diameter of the screw and 22 undergoing no overdrilling. A 4-point bending test followed torsional fatigue of 1000 cycles with an amplitude of +/-10 degrees. The post-fatigued samples were retested in the same way after tightening the loose screws if necessary. Finally, each fatigued specimen was tested for failure in torsion at 0.5 Hz by applying a maximum rotational displacement of 60 degrees .The bending stiffness values (Nm/mm) of cortical and locking screws, with the exception of the hybrid system, were significantly higher for the overdrilled group than the non-overdrilled (cortical, 6.9 vs 5.6; locking, 9.1 vs 6.3; hybrid, 8.4 vs 6.8). Fatigue had no effect on the bending stiffness of all the screw/plate systems (cortical, 6.9 vs 7.4; locking, 9.1 vs 8.8; hybrid, 8.5 vs 8.1). The overdrilling had no effect on the failure loads and displacements for all the screws except cortical screws, where the failure displacement was significantly higher for the overdrilling group. The torsional stiffness retentions after 1000 cycles were significantly different for overdrilled specimens in the cortical screws group only.Overdrilling had a minimal effect on bending and torsional properties. The results of the locking and hybrid were close, and the cortical screw had only slightly lower bending stiffness.

  15. Automated DNA Sequencing System

    SciTech Connect

    Armstrong, G.A.; Ekkebus, C.P.; Hauser, L.J.; Kress, R.L.; Mural, R.J.

    1999-04-25

    Oak Ridge National Laboratory (ORNL) is developing a core DNA sequencing facility to support biological research endeavors at ORNL and to conduct basic sequencing automation research. This facility is novel because its development is based on existing standard biology laboratory equipment; thus, the development process is of interest to the many small laboratories trying to use automation to control costs and increase throughput. Before automation, biology Laboratory personnel purified DNA, completed cycle sequencing, and prepared 96-well sample plates with commercially available hardware designed specifically for each step in the process. Following purification and thermal cycling, an automated sequencing machine was used for the sequencing. A technician handled all movement of the 96-well sample plates between machines. To automate the process, ORNL is adding a CRS Robotics A- 465 arm, ABI 377 sequencing machine, automated centrifuge, automated refrigerator, and possibly an automated SpeedVac. The entire system will be integrated with one central controller that will direct each machine and the robot. The goal of this system is to completely automate the sequencing procedure from bacterial cell samples through ready-to-be-sequenced DNA and ultimately to completed sequence. The system will be flexible and will accommodate different chemistries than existing automated sequencing lines. The system will be expanded in the future to include colony picking and/or actual sequencing. This discrete event, DNA sequencing system will demonstrate that smaller sequencing labs can achieve cost-effective the laboratory grow.

  16. Polymer cable/grip-plate system with locking screws for stable fixation to promote healing of trochanteric osteotomies or fractures in revision total hip arthroplasty.

    PubMed

    Berend, Keith R; Willen, Jacob L; Morris, Michael J; Adams, Joanne B; Lombardi, Adolph V

    2014-11-01

    Multiple methods have been proposed to establish stable fixation to promote healing of trochanteric osteotomies or fractures in revision total hip arthroplasty (revTHA), from wiring techniques through cable-plate systems with or without supplemental locking screws. The purpose of this study is to report the clinical results of a single cable-plate system with locked screw fixation in revTHA. Between 2009 and 2012, 27 grip-plates (Supercable® System, Kinamed Inc., Camarillo, CA) were used in 26 patients in 27 revTHA procedures. Utilization was 12 1-hole (50 mm) grip-plates, 10 2-hole (135 mm) grip-plates, four 4-hole (190 mm) grip-plates, and one 6-hole (245 mm) grip-plate. There were 14 women and 12 men. Age averaged 63.2 years and BMI averaged 29.4 kg/m2. At average 2.5 year follow-up, grip-plate fixation was considered successful in 22 hips (81%) with five failures. Three failures consisted of 50 mm/short grip-plates used in one trochanteric slide, and two intraoperative trochanteric fractures during revTHA. The two additional failures were related to pre-revision trochanteric avulsion from bony necrosis of the proximal femur. An additional three grip-plates were removed electively for soft-tissue irritation and pain but with successful fixation and bony healing. Thus 70% of hips were free of reoperation related to the grip-plate. All other hips had successful fixation and the grip-plate was not symptomatic. In this study, the cable-grip system and isoelastic Supercables provided reliable fixation for adequate healing of difficult ETO and trochanteric fractures with an 81% rate of mechanical success with radiographic and clinical healing observed.

  17. Simple optical system for manufacturing point diffraction interferometer plates in titanium films using a low intensity CW laser beam

    NASA Astrophysics Data System (ADS)

    Aguilar, Juan C.; Aguilar, J. Félix; Berriel-Valdos, L. R.

    2014-11-01

    We propose an optical system for making pinholes in titanium films for applications in point diffraction interferometry. The optical system for fabrication is easy to implement and to align and, as a result of this, it is possible to obtain pinholes in the range of 1 to 8 μm of diameter. The technique is based on laser ablation and, since we use a green laser, the spot produced by the focus of the optical system can be observed. Also, the damage over the titanium film can be monitored with the aid of a microscope objective lens in real time. The new technique is described and the resulting plates with the pinholes are shown. A successful application of the plates in interferometry is presented as well.

  18. Biofeedback control analysis using a synchronized system of two CCD video cameras and a force-plate sensor

    NASA Astrophysics Data System (ADS)

    Tsuruoka, Masako; Shibasaki, Ryosuke; Murai, Shunji

    1999-01-01

    The biofeedback control analysis of human movement has become increasingly important in rehabilitation, sports medicine and physical fitness. In this study, a synchronized system was developed for acquiring sequential data of a person's movement. The setup employs a video recorder system linked with two CCD video cameras and fore-plate sensor system, which are configured to stop and start simultaneously. The feedback control movement of postural stability was selected as a subject for analysis. The person's center of body gravity (COG) was calculated by measured 3-D coordinates of major joints using videometry with bundle adjustment and self-calibration. The raw serial data of COG and foot pressure by measured force plate sensor are difficult to analyze directly because of their complex fluctuations. Utilizing auto regressive modeling, the power spectrum and the impulse response of movement factors, enable analysis of their dynamic relations. This new biomedical engineering approach provides efficient information for medical evaluation of a person's stability.

  19. Development of a System to Measure Austenite Grain Size of Plate Steel Using Laser-Based Ultrasonics

    SciTech Connect

    Lim, C. S.; Hong, S. T.; Yi, J. K.; Choi, S. G.; Oh, K. J.; Nagata, Y.; Yamada, H.; Hamada, N.

    2007-03-21

    A measurement system for austenite grain size of plate steel using laser-based ultrasonics has been developed. At first, the relationship between the ultrasonic attenuation coefficients using longitudinal waves and austenite grain size of samples was investigated in the laboratory experiments. According to the experimental results, the ultrasonic attenuation coefficients showed a good correlation with actual austenite grain sizes. For the next step, the system was installed in a hot rolling pilot plant of plate steel, and it was verified that the austenite grain size could be measured even in the environment of a hot rolling pilot plant. In the experiments, it was also confirmed that the fiber delivery system could deliver Nd:YAG laser beam of 810 mJ/pulse and ultrasonic signals could be obtained successfully.

  20. Experimental Fault Diagnosis in Systems Containing Finite Elements of Plate of Kirchoff by Using State Observers Methodology

    NASA Astrophysics Data System (ADS)

    Alegre, D. M.; Koroishi, E. H.; Melo, G. P.

    2015-07-01

    This paper presents a methodology for detection and localization of faults by using state observers. State Observers can rebuild the states not measured or values from points of difficult access in the system. So faults can be detected in these points without the knowledge of its measures, and can be track by the reconstructions of their states. In this paper this methodology will be applied in a system which represents a simplified model of a vehicle. In this model the chassis of the car was represented by a flat plate, which was divided in finite elements of plate (plate of Kirchoff), in addition, was considered the car suspension (springs and dampers). A test rig was built and the developed methodology was used to detect and locate faults on this system. In analyses done, the idea is to use a system with a specific fault, and then use the state observers to locate it, checking on a quantitative variation of the parameter of the system which caused this crash. For the computational simulations the software MATLAB was used.

  1. Surgical repair of a severely comminuted maxillary fracture in a dog with a titanium locking plate system.

    PubMed

    Illukka, E; Boudrieau, R J

    2014-01-01

    A four-year old male Labrador Retriever was admitted with head trauma after being hit by a car. The dog had sustained multiple nasal, maxillary, and frontal bone fractures that resulted in separation of the maxilla from the base of the skull. A severely comminuted left zygomatic arch fracture was also present. These fractures were all repaired using a point contact, locking titanium plate system, in a single procedure that resulted in excellent postoperative occlusion and immediate function. Healing was uneventful. Full function and excellent cosmetic appearance were evident 13 months after surgery. This case illustrates the ease of repair and the success of treatment of severely comminuted maxillofacial fractures by conforming to basic biomechanical principles taken directly from the human experience and successfully applied to the dog; these included multiple plate application along the buttresses and trusses of the facial skeleton. The plate fixation was applied to bridge the multiple fractures along the most appropriate lines of stress. The small size of the plates, and the ability to easily contour them to adapt to the bone surface in three-dimensions, allowed their placement in the most appropriate positions to achieve sufficient rigidity and lead to uncomplicated healing without any postoperative complications. PMID:25088587

  2. Mutual Inductance Problem for a System Consisting of a Current Sheet and a Thin Metal Plate

    NASA Technical Reports Server (NTRS)

    Fulton, J. P.; Wincheski, B.; Nath, S.; Namkung, M.

    1993-01-01

    Rapid inspection of aircraft structures for flaws is of vital importance to the commercial and defense aircraft industry. In particular, inspecting thin aluminum structures for flaws is the focus of a large scale R&D effort in the nondestructive evaluation (NDE) community. Traditional eddy current methods used today are effective, but require long inspection times. New electromagnetic techniques which monitor the normal component of the magnetic field above a sample due to a sheet of current as the excitation, seem to be promising. This paper is an attempt to understand and analyze the magnetic field distribution due to a current sheet above an aluminum test sample. A simple theoretical model, coupled with a two dimensional finite element model (FEM) and experimental data will be presented in the next few sections. A current sheet above a conducting sample generates eddy currents in the material, while a sensor above the current sheet or in between the two plates monitors the normal component of the magnetic field. A rivet or a surface flaw near a rivet in an aircraft aluminum skin will disturb the magnetic field, which is imaged by the sensor. Initial results showed a strong dependence of the flaw induced normal magnetic field strength on the thickness and conductivity of the current-sheet that could not be accounted for by skin depth attenuation alone. It was believed that the eddy current imaging method explained the dependence of the thickness and conductivity of the flaw induced normal magnetic field. Further investigation, suggested the complexity associated with the mutual inductance of the system needed to be studied. The next section gives an analytical model to better understand the phenomenon.

  3. Preliminary design review package on air flat plate collector for solar heating and cooling system

    NASA Technical Reports Server (NTRS)

    1977-01-01

    Guidelines to be used in the development and fabrication of a prototype air flat plate collector subsystem containing 320 square feet (10-4 ft x 8 ft panels) of collector area are presented. Topics discussed include: (1) verification plan; (2) thermal analysis; (3) safety hazard analysis; (4) drawing list; (5) special handling, installation and maintenance tools; (6) structural analysis; and (7) selected drawings.

  4. Distal radius fractures-Design of locking mechanism in plate system and recent surgical procedures.

    PubMed

    Inagaki, Katsunori; Kawasaki, Keikichi

    2016-05-01

    Recently, many studies have emphasized the importance of the comprehension of detailed functional anatomy of the distal forearm and wrist joint, and their biomechanics. A significant contribution which yields good functional outcomes of surgical treatment was the development of the locking plate technology; this technology has facilitated the improvement of the surgical technique for the fixation of fractures. This article reviews the locking mechanism and design of the fixation screws and plate, and the details of the surgical technique including the double-tired subchondral support procedure as it is applied to common fractures. Arthroscopic-assisted surgical procedures can be used to reduce the intra-articular fracture fragments after realignment of the distal radius with the locking plate. This technique is also useful at the time of fixation to assess soft tissue injury. The combination of arthroscopic-assisted reduction and locking plate fixation is now indicated for AO type C2 and C3 intra-articular comminuted fractures. PMID:27006135

  5. Tectonic controls on the stratigraphic architecture and hydrocarbons systems of the Arabian Plate

    SciTech Connect

    Grabowski, G.J. Jr.; Norton, I.O.

    1995-12-31

    Arabian Platform sediments consist of major sequences separated by tectonically controlled unconformities. These tectonic events, at the plate margins, controlled the orientation and distribution of sedimentary facies on the stable platform. Eustacy and subsidence were the principle controls on the actual facies that formed.

  6. The influence of plate boundary deformation on regional intraplate exhumation: evidence from the Irish Sea basin system, western UK

    NASA Astrophysics Data System (ADS)

    Holford, S. P.; Turner, J. P.; Green, P. F.; Williams, G. A.

    2005-12-01

    Elucidating the causes of exhumation within intraplate regions and passive margin settings is an outstanding problem with global tectonic significance. The application of thermochronological tools such as apatite fission-track analysis (AFTA) across apparently stable intraplate regions (e.g. NW Europe, SW Australia, Southern Africa) has repeatedly revealed evidence for extensive phases of km-scale exhumation, often with no obvious causal mechanisms. Here we present results from a study of the exhumation history of the Irish Sea basin system (western UK) using palaeothermal (AFTA and VR), compactional and seismic reflection data which highlights the dominant control that plate boundary processes exert over the uplift and exhumation of continental interiors. This intraplate Mesozoic-Cenozoic basin system occupies the transition between the European Alpine deformation front and the NE Atlantic passive margin. Numerous studies have identified this area as one of the most severely exhumed in NW Europe. Much of this exhumation has been ascribed to Palaeocene epeirogeny caused by the Iceland Plume. However, our results reveal an exhumation history of far greater complexity with major exhumation episodes during the early Cretaceous (120-115 Ma) and Neogene (<20 Ma) removing up to 3 km and 1.5 km of Mesozoic-Cenozoic sediments from this region respectively. Mapping of early Cenozoic exhumation patterns reveals major heterogeneities in exhumation magnitudes at intra-basinal (<10 km) and regional (<100 km) scales which cannot be ascribed to a purely epeirogenic process such as plume-driven uplift. These regional phases of intraplate exhumation are coincident with important phases of deformation at preexisting or incipient plate boundaries. Early Cretaceous exhumation was coeval with the onset of seafloor spreading in Bay of Biscay. Neogene exhumation was coincident with the late Alpine orogenesis, with abundant evidence for Neogene compressional shortening in this study area

  7. 100 Ma: the new frontier for quantitative global models of the coupled brittle-plates/viscous-mantle system.

    NASA Astrophysics Data System (ADS)

    Stotz, Ingo; Iaffaldano, Giampiero; Davies, Rhodri

    2014-05-01

    Over recent decades the body of geophysical datasets has grown substantially and rapidly. Ocean-floor observations now allow one to unravel past plate motions (for instance, in the North Atlantic and Indian Ocean over the past 20 Myr) at the unprecedented temporal resolution of about 1 Myr; and more data is anticipated in the near future. Similarly, our knowledge of continental evolution has grown due to advances in interpreting the records of orogeny and sedimentation. Altogether, these ever-growing datasets allow us to reconstruct the past evolution of Earth's lithospheric plates in greater detail than previously achieved. This is key to unravel the dynamics of geological processes, because reconstructed plate motions and their temporal changes are a powerful probe into the evolving balance of shallow- and deep-rooted forces. Such progress, however, is not yet matched by the ability to quantitatively model past plate-motion changes and, therefore to test hypotheses on the dominant geological controls. The main technical challenge is simulating the rheological behaviour of the plates/mantle system, which varies significantly from viscous to brittle. Classically, computer models for viscous mantle flow and for the piecewise motions of the brittle lithosphere have been developed separately. In recent years, coupling of these two independent classes of models has been pioneered, but only for neo-tectonic scenarios (i.e. past few Myr), and with some limitations as to accounting for the impact of evolving mantle-flow on plate motions. It is now timely to further advance the technical ability to simulate the coupled plates/mantle system through geological time (for instance throughout the Cenozoic and possibly the Cretaceous), and to use the growing body of geophysical data as a primary constraint on these quantitative models. In this project, we take steps in this direction. We build on previous work aimed at coupling two advanced codes for mantle flow and lithosphere

  8. Management of pediatric mandibular fractures using bioresorbable plating system – Efficacy, stability, and clinical outcomes: Our experiences and literature review

    PubMed Central

    Singh, Mahinder; Singh, R.K.; Passi, Deepak; Aggarwal, Mohit; Kaur, Guneet

    2015-01-01

    Aims The purpose of this study was to determine the efficacy and stability of the biodegradable fixation system for treatment of mandible fractures in pediatric patients by measuring the bite force. Methods Sixty pediatric patients with mandibular fractures (36 males, 24 females) were included in this study. The 2.5-mm resorbable plates were adapted along Champy's line of ideal osteosynthesis and secured with four 2.5 mm diameter monocortical resorbable screws, 8 mm in length. All patients were followed for 10 months. Clinical parameters, such as soft tissue infection, nonunion, malunion, implant exposure, malocclusion, nerve injury, and bite force for stability, were prospectively assessed. Results Adequate fixation and primary bone healing was achieved in 100% of the cases. Six minor complications (10%) were observed: 2 soft tissue infections (3%), 1 plate dehiscence (2%), 1 malocclusion (2%), and 2 paresthesia (3%). Conclusion 2.5-mm resorbable plating system along Champy's line of ideal osteosynthesis is a good treatment modality for mandible fractures in pediatric patients. PMID:27195206

  9. Experimental Simulation of Active Control With On-line System Identification on Sound Transmission Through an Elastic Plate

    NASA Technical Reports Server (NTRS)

    1998-01-01

    An adaptive control algorithm with on-line system identification capability has been developed. One of the great advantages of this scheme is that an additional system identification mechanism such as an additional uncorrelated random signal generator as the source of system identification is not required. A time-varying plate-cavity system is used to demonstrate the control performance of this algorithm. The time-varying system consists of a stainless-steel plate which is bolted down on a rigid cavity opening where the cavity depth was changed with respect to time. For a given externally located harmonic sound excitation, the system identification and the control are simultaneously executed to minimize the transmitted sound in the cavity. The control performance of the algorithm is examined for two cases. First, all the water was drained, the external disturbance frequency is swept with 1 Hz/sec. The result shows an excellent frequency tracking capability with cavity internal sound suppression of 40 dB. For the second case, the water level is initially empty and then raised to 3/20 full in 60 seconds while the external sound excitation is fixed with a frequency. Hence, the cavity resonant frequency decreases and passes the external sound excitation frequency. The algorithm shows 40 dB transmitted noise suppression without compromising the system identification tracking capability.

  10. Fixation of sternal fracture using absorbable plating system, three years follow-up

    PubMed Central

    Katballe, Niels; Pilegaard, Hans

    2015-01-01

    Sternal fractures occur due to severe chest wall trauma in a small number of patients. They are often conservatively treated. The surgical intervention, although controversial, is indicated in case of deformity, severe pain, and ventilatory complications. We report the first case where absorbable plate has been used to fix a traumatic fracture in a 42-year-old female. After 3 years, the patient is still free of symptoms and CT scanning reveals intact sternal bone structure. PMID:26101659

  11. Drag reducing effects of polymer additives in a plate heat exchanger for the OTEC system

    SciTech Connect

    Kim, N.; Yoon, S.; Kim, C.; Seo, T.

    1999-07-01

    Experiments were undertaken for a 15kW Alfa-Laval plate heat exchanger utilizing polyethylene oxide as a polymer additive. Concentrations of polymer additives were 5, 10, 20, 30, 40, 50, 100, 200 and 400 wppm at 25 C and mass flow rates were 0.6kg/s, 0.7kg/s, 0.8kg/s and 0.9kg/s in normal operating ranges of the plate heat exchanger. The maximum effects of drag reductions were found at 20 wppm polymer concentration and at approximately 0.7kg/s of mass flow rate. The results show that there exist optimum polymer concentration and at approximately 0.7kg/s of mass flow rate. The results show that there exist optimum polymer concentration and mass flow rate for the plate heat exchanger for maximum drag reduction effects. In most cases, drag reduction of approximately 20% has been obtained. It means considerable savings in pumping power for a large size OTEC plant.

  12. Understanding plate-motion changes over the past 100 Myr with quantitative models of the coupled lithosphere/mantle system

    NASA Astrophysics Data System (ADS)

    Stotz, Ingo; Iaffaldano, Giampiero; Rhodri Davies, D.

    2015-04-01

    The volume of geophysical datasets has grown substantially over recent decades. Our knowledge of continental evolution has increased due to advances in interpreting the records of orogeny and sedimentation. Ocean-floor observations now allow one to resolve past plate motions (e.g. in the North Atlantic and Indian Ocean over the past 20 Myr) at temporal resolutions of about 1 Myr. Altogether, these ever-growing datasets allow us to reconstruct the past evolution of Earth's lithospheric plates in greater detail. This is key to unravelling the dynamics of geological processes, because plate motions and their temporal changes are powerful probe into the evolving force balance between shallow- and deep-rooted processes. However, such progress is not yet matched by the ability to quantitatively model past plate-motion changes and, therefore, to test hypotheses on the dominant controls. The main technical challenge is simulating the rheological behaviour of the lithosphere/mantle system, which varies significantly from viscous to brittle. Traditionally computer models for viscous mantle flow on the one hand, and for the motions of the brittle lithosphere on the other hand, have been developed separately. Coupling of these two independent classes of models has been accomplished only for neo-tectonic scenarios, without accounting for the impact of time-evolving mantle-flow (e.g. Iaffaldano and Bunge 2009). However, we have built a coupled model to simulate the lithosphere/mantle system (using SHELLS and TERRA, respectively) through geological time, and to exploit the growing body of geophysical data as a primary constraint on these quantitative models. TERRA is a global spherical finite-element code for mantle convection (e.g. Baumgardner 1985, Bunge et al. 1996, Davies et al. 2013), whilst SHELLS is a thin-sheet finite-element code for lithosphere dynamics (e.g. Bird 1998). Our efforts are focused, in particular, on achieving the technical ability to: (i) simulate the

  13. Favorable locations for piezo actuators in plates with good control effectiveness and minimal change in system dynamics

    NASA Astrophysics Data System (ADS)

    Dhuri, K. D.; Seshu, P.

    2007-12-01

    Placement and sizing of piezo actuators is normally based on control effectiveness. However, retrofitting of piezoelectric actuators alters the inherent stiffness/mass properties of the parent structure. In rotating structures, the additional mass due to piezo patches contributes to the centrifugal stiffening force. The parent structure is originally designed to have a certain natural frequency spectrum in relation to the disturbance excitation. In the event of failure of the active system, the dynamics of the structure with piezos (now rendered passive) will therefore become significant. Thus it will be helpful to determine locations for mounting piezo patches based on minimal natural frequency change yet with good control authority. In this study, a finite element based procedure for plate structures is presented. Favorable locations for mounting piezos based on minimal natural frequency changes are iteratively evolved from an initial configuration wherein the whole plate is covered with piezos. A modal controllability approach has been used for finding piezo mounting locations from a good controllability perspective. The procedure is demonstrated for simply supported square, swept-back, circular and rotating rectangular plates considering the first four modes.

  14. Investigation of the decolorization efficiency of two pin-to-plate corona discharge plasma system for industrial wastewater treatment

    NASA Astrophysics Data System (ADS)

    El-Tayeb, A.; El-Shazly, A. H.; Elkady, M. F.; Abdel-Rahman, A. B.

    2016-09-01

    In this article, a dual pin-to-plate high-voltage corona discharge system is introduced to study experimentally the gap distance, the contact time, the effect of pin and plate materials, the thickness of ground plate and the conductivity on the amount of Acid Blue 25 dye color removal efficiency from polluted water. A study for the optimum air gap distance between dual pin and surface of Acid Blue 25 dye solution is carried out using 3D-EM simulator to find maximum electric field intensity at the tip of both pins. The outcomes display that the best gap for corona discharge is approximately 5 mm for 15-kV source. This separation is constant during the study of other factors. In addition, an investigation of the essential reactive species responsible for oxidation of the dye organic compounds (O3 in air discharge, O3 in water, and H2O2) during the experimental time is conducted. Three various materials such as: stainless steel, copper and aluminum are used for pins and plate. The maximum color removal efficiencies of Acid Blue 25 dyes are 99.03, 82.04, and 90.78% after treatment time 15 min for stainless steel, copper, and aluminum, respectively. Measurement results for the impact of thickness of an aluminum ground plate on color removal competence show color removal efficiencies of 86.3, 90.78, and 98.06% after treatment time 15 min for thicknesses of 2, 0.5, and 0.1 mm, respectively. The increasing of the solution conductivity leads to the reduction of decolorization efficiency. A kinetic model is used to define the performance of corona discharge system. The models of pseudo-zero-order, pseudo-first-order, and pseudo-second-order reaction kinetics are utilized to investigate the decolorization of Acid Blue 25 dye. The rate of degradation of Acid Blue 25 dye follows the pseudo-first-order kinetics in the dye concentration.

  15. A Comparison of Ground Reaction Forces Determined by Portable Force-Plate and Pressure-Insole Systems in Alpine Skiing

    PubMed Central

    Nakazato, Kosuke; Scheiber, Peter; Müller, Erich

    2011-01-01

    For the determination of ground reaction forces in alpine skiing, pressure insole (PI) systems and portable force plate (FP) systems are well known and widely used in previous studies. The purposes of this study were 1) to provide reference data for the vertical component of the ground reaction forces (vGRF) during alpine skiing measured by the PI and FP systems, and 2) to analyze whether the differences in the vGRF measured by the PI and the FP depend on a skier’s level, skiing mode and pitch. Ten expert and ten intermediate level skiers performed 10 double turns with the skiing technique “Carving in Short Radii” as High Dynamic Skiing mode and “Parallel Ski Steering in Long Radii” as Low Dynamic Skiing mode on both the steep (23 °) and the flat (15 °) slope twice. All subjects skied with both the PI and the FP system simultaneously. During the outside phase, the mean vGRF and the maximum vGRF determined by the FP are greater than the PI (p < 0.01). Additionally during the inside phase, the mean vGRF determined by the FP were greater than the PI (p < 0.01). During the edge changing phases, the mean vGRF determined by the FP were greater than the PI (p < 0.01). However, the minimum vGRF during the edge changing phases determined by the FP were smaller than the PI (p < 0.01) in the High-Steep skiing modes of Experts and Intermediates (p < 0.001). We have found that generally, the PI system underestimates the total vGRF compared to the FP system. However, this difference depends not only the phase in the turn (inside, outside, edge changing), but also is affected by the skier’s level, the skiing mode performed and pitch. Key points Typically, during the steering phases of the ski turns the total vGRFs measured by the pressure-insole system were lower compared to the portable force-plate system. However, in some skiing modes during the edge changing phase, the pressure-insole system overestimates the total vGRF compared to the portable force-plate system

  16. Building America Case Study: Advanced Extended Plate and Beam Wall System in a Cold-Climate House, Mount Joy, Pennsylvania

    SciTech Connect

    2016-01-01

    This report presents the design and evaluation of a innovative wall system. This highly insulated (high-R) light-frame wall system for use above grade in residential buildings is referred to as Extended Plate & Beam (EP&B). The EP&B design is the first of its kind to be featured in a new construction test house (NCTH) for the DOE Building America program. The EP&B wall design integrates standard building methods and common building products to construct a high-R wall that minimizes transition risks and costs to builders. The EP&B design combines optimized framing with integrated rigid foam sheathing to increase the wall system's R-value and reduce thermal bridging. The foam sheathing is installed between the wall studs and structural wood sheathing. The exterior wood sheathing is attached directly to a framing extension formed by extended top and bottom plates. The exterior wood sheathing can dry to the exterior and provides bracing, a clear drainage plane and flashing surface for window and door openings, and a nailing surface for siding attachment. With support of the DOE Building America program, Home Innovation Research Labs partnered with Lancaster County Career and Technology Center (LCCTC) to build a NCTH in Lancaster, PA to demonstrate the EP&B wall design in a cold climate (IECC climate zone 5A). The results of the study confirmed the benefits of the systems and the viability of its integration into the house construction process.

  17. Miniaturized plate readers for low-cost, high-throughput phenotypic screening.

    PubMed

    Jensen, Paul A; Dougherty, Bonnie V; Moutinho, Thomas J; Papin, Jason A

    2015-02-01

    We present a miniaturized plate reader for measuring optical density in 96-well plates. Our standalone reader fits in most incubators, environmental chambers, or biological containment suites, allowing users to leverage their existing laboratory infrastructure. The device contains no moving parts, allowing an entire 96-well plate to be read several times per second. We demonstrate how the fast sampling rate allows our reader to detect small changes in optical density, even when the device is placed in a shaking incubator. A wireless communication module allows remote monitoring of multiple devices in real time. These features allow easy assembly of multiple readers to create a scalable, accurate solution for high-throughput phenotypic screening. PMID:25366331

  18. Use of a Fluorometric Imaging Plate Reader in high-throughput screening

    NASA Astrophysics Data System (ADS)

    Groebe, Duncan R.; Gopalakrishnan, Sujatha; Hahn, Holly; Warrior, Usha; Traphagen, Linda; Burns, David J.

    1999-04-01

    High-throughput screening (HTS) efforts at Abbott Laboratories have been greatly facilitated by the use of a Fluorometric Imaging Plate Reader. The FLIPR consists of an incubated cabinet with integrated 96-channel pipettor and fluorometer. An argon laser is used to excite fluorophores in a 96-well microtiter plate and the emitted fluorometer. An argon laser is used to excite fluorophores in a 96-well microtiter plate and the emitted fluorescence is imaged by a cooled CCD camera. The image data is downloaded from the camera and processed to average the signal form each well of the microtiter pate for each time point. The data is presented in real time on the computer screen, facilitating interpretation and trouble-shooting. In addition to fluorescence, the camera can also detect luminescence form firefly luciferase.

  19. Fenton-biological treatment of reverse osmosis membrane concentrate from a metal plating wastewater recycle system.

    PubMed

    Huang, R M; He, J Y; Zhao, J; Luo, Q; Huang, C M

    2011-04-01

    Although reverse osmosis (RO) has been widely used in the recycling of metal plating wastewater, organic compounds and heavy metals in the RO concentrate are difficult to remove by conventional treatment. A combination process including Fenton oxidation and a biological aerated filter was used to treat RO concentrate containing complex Cu and Ni from metal plating. During the Fenton treatment, Cu and Ni ions were released due to degradation of organic compounds and then removed by pH adjustment and coagulation. The concentrate was further treated using by a biological aerated filter. Optimum conditions were as follows: initial pH of influent of 4.0; dosage of H2O2 of 5.0 mmol l(-1); ratio of n(Fe2+)/n(H2O2) of 0.8; precipitation pH of Cu and Ni ions of 8.0; and a hydraulic retention time of the biological aerated filter of 2.5 h. The results showed that concentrations of effluent COD, Cu and Ni ions were less than 40 mg l(-1), 0.5 mg l(-1) and 0.3 mg l(-1), respectively; this means the treated effluent meets the emission standards for pollutants from electroplating set by China's Environmental Protection Agency. PMID:21877532

  20. Conception through build of an automated liquids processing system for compound management in a low-humidity environment.

    PubMed

    Belval, Richard; Alamir, Ab; Corte, Christopher; DiValentino, Justin; Fernandes, James; Frerking, Stuart; Jenkins, Derek; Rogers, George; Sanville-Ross, Mary; Sledziona, Cindy; Taylor, Paul

    2012-12-01

    Boehringer Ingelheim's Automated Liquids Processing System (ALPS) in Ridgefield, Connecticut, was built to accommodate all compound solution-based operations following dissolution in neat DMSO. Process analysis resulted in the design of two nearly identical conveyor-based subsystems, each capable of executing 1400 × 384-well plate or punch tube replicates per batch. Two parallel-positioned subsystems are capable of independent execution or alternatively executed as a unified system for more complex or higher throughput processes. Primary ALPS functions include creation of high-throughput screening plates, concentration-response plates, and reformatted master stock plates (e.g., 384-well plates from 96-well plates). Integrated operations included centrifugation, unsealing/piercing, broadcast diluent addition, barcode print/application, compound transfer/mix via disposable pipette tips, and plate sealing. ALPS key features included instrument pooling for increased capacity or fail-over situations, programming constructs to associate one source plate to an array of replicate plates, and stacked collation of completed plates. Due to the hygroscopic nature of DMSO, ALPS was designed to operate within a 10% relativity humidity environment. The activities described are the collaborative efforts that contributed to the specification, build, delivery, and acceptance testing between Boehringer Ingelheim Pharmaceuticals, Inc. and the automation integration vendor, Thermo Scientific Laboratory Automation (Burlington, ON, Canada).

  1. Prescreening bacterial colonies for bioactive molecules with Janus plates, a SBS standard double-faced microbial culturing system.

    PubMed

    Sánchez-Hidalgo, Marina; Pascual, Javier; de la Cruz, Mercedes; Martín, Jesús; Kath, Gary S; Sigmund, Janet M; Masurekar, Prakash; Vicente, Francisca; Genilloud, Olga; Bills, Gerald F

    2012-08-01

    Despite the availability of many culture-based antibiotic screening methods, the lack of sensitive automated methods to identify functional molecules directly from microbial cells still limits the search for new biologically active compounds. The effectiveness of antibiotic detection is influenced by the solubility of the assayed compounds, indicator strain sensitivity, culture media and assay configuration. We describe a qualitative high throughput screening system for detecting cell-perturbing molecules from bacterial colonies employing two opposed agar layers sequentially formed in prototype Society for Biomolecular Screening (SBS) plates, named Janus plates. Direct assay of microbial colonies against target organisms in opposed agar layers overcomes some of the limitations of agar overlay methods. The system enables the rapid detection of extracellular cell-perturbing molecules, e.g., antibiotics, excreted directly from environmental isolates. The source bacterial colonies remain separate from the target organism. The growth layer is prepared and grown independently, so environmental strains can be grown for longer intervals, at temperatures and in media that favor their growth and metabolite expression, while the assay layer with pathogens, usually requiring nutrient-rich medium and elevated temperatures, are added later. Colonies to be tested can be precisely arrayed on the first agar surface, thus avoiding dispersion and disturbance of potential antibiotic-producing colonies by overlaying agar with the target strain. The rectangular SBS configuration facilitates factorial replication of dense microbial colony arrays for testing with multiple assays and assay conditions employing robotic colony pickers and pin tools. Opposed agar layers only slightly reduced the effectiveness for detecting growth inhibition from pure antibiotics compared to single-layer agar diffusion assays. The Janus plate enabled an automation-assisted workflow where a lone operator can

  2. A wearable force plate system for the continuous measurement of triaxial ground reaction force in biomechanical applications

    NASA Astrophysics Data System (ADS)

    Liu, Tao; Inoue, Yoshio; Shibata, Kyoko

    2010-08-01

    The ambulatory measurement of ground reaction force (GRF) and human motion under free-living conditions is convenient, inexpensive and never restricted to gait analysis in a laboratory environment and is therefore much desired by researchers and clinical doctors in biomedical applications. A wearable force plate system was developed by integrating small triaxial force sensors and three-dimensional (3D) inertial sensors for estimating dynamic triaxial GRF in biomechanical applications. The system, in comparison to existent systems, is characterized by being lightweight, thin and easy-to-wear. A six-axial force sensor (Nitta Co., Japan) was used as a verification measurement device to validate the static accuracy of the developed force plate. To evaluate the precision during dynamic gait measurements, we compared the measurements of the triaxial GRF and the center of pressure (CoP) by using the developed system with the reference measurements made using a stationary force plate and an optical motion analysis system. The root mean square (RMS) differences of the two transverse components (x- and y-axes) and the vertical component (z-axis) of the GRF were 4.3 ± 0.9 N, 6.0 ± 1.3 N and 12.1 ± 1.1 N, respectively, corresponding to 5.1 ± 1.1% and 6.5 ± 1% of the maximum of each transverse component and 1.3 ± 0.2% of the maximum vertical component of GRF. The RMS distance between the two systems' CoP traces was 3.2 ± 0.8 mm, corresponding to 1.2 ± 0.3% of the length of the shoe. Moreover, based on the results of the assessment of the influence of the system on natural gait, we found that gait was almost never affected. Therefore, the wearable system as an alternative device can be a potential solution for measuring CoP and triaxial GRF in non-laboratory environments.

  3. European Plate Observing System - the Arctic dimension and the Nordic collaboration

    NASA Astrophysics Data System (ADS)

    Atakan, K.; Heikkinen, P.; Juhlin, C.; Thybo, H.; Vogfjord, K.

    2012-04-01

    Within the framework of the EPOS project, Nordic interests are significant, not only in fundamental scientific issues related to geodynamic processes, but also in terms of the application of these to several central problems such as, hydrocarbon exploration and production including the related environmental issues, CO2 storage (or other toxic waste repositories) in geological formations, geothermal energy (natural and hot-dry rock) utilization and mining, geohazards (earthquakes, landslides and volcanic eruptions) and their consequences to the society. The Arctic dimension including Fennoscandia, the northern North Atlantic and the Arctic Sea constitutes an area of considerable geographical extent within the European plate. The region also contains a significant part of the European plate boundary submerged under the North Atlantic and the Arctic sea, where geodynamic processes such as rifting and fracturing are especially energetic. In particular, where the plate boundary is exposed on land in the South Iceland seismic zone, large earthquakes are frequently observed including two Mw6.5 events in 2000 and one Mw6.3 event in 2008. But, seismic hazard is not confined to the plate boundary. Significant intra-plate earthquakes have recently occurred in the region (Mw6.1 in the continental shelf near Spitsbergen in 2008, Mw5.0 in Southern Sweden in 2008, Mw5.2 near Kaliningrad in 2004) showing that there is considerable seismic hazard in the region. In addition, submarine landslide earthquakes are always of concern due to possible tsunami generation. Volcanic activity occurs on the plate boundary and is particularly strong in the rift zones of Iceland, where on average two volcanic eruptions occur per decade. subaerial volcanic eruptions also occur on Jan Mayen island, farther north on the Mid Atlantic ridge. Together, the Danish seismic network in Greenland, the Norwegian seismic arrays and national network traversing the length of Norway and the Icelandic seismic and

  4. Matrix based system of isotretinoin as nail lacquer to enhance transungal delivery across human nail plate.

    PubMed

    Joshi, Monika; Sharma, Vijay; Pathak, Kamla

    2015-01-15

    The project was aimed at development of isotretinoin nail lacquer and assessment of its penetration efficiency across human nail plate. Preliminary studies (hydration enhancement factor and SEM) aided the selection of thioglycolic acid as permeation and eugenol was selected as local anesthetic in the formulation. The nail lacquer was optimized by 3(2) factorial design and a total of nine formulations were prepared and screened. In vitro adhesion and ex vivo permeation (cumulative drug permeation per unit area (CDP/A) = 6.61 ± 0.57 mg/cm(2)) across bovine hoof guided the selection of F3 as optimized formulation that was improvised. Viscosity adjustments to improve handling characteristics were affected by incorporation of ethyl cellulose (6%; F3M1) that scaled the viscosity to 312.681 cp and insignificantly (p > 0.05) affected CDP/A (6.32 ± 0.45 mg/cm(2)). In comparison to marketed preparation (Retino-A cream) F3M1 afforded two fold increase in CDP/A. The permeation characteristics were defined by Higuchi model (r(2) = 0.964) and flux value of 176 μg/cm(2)/h. Confocal laser scanning microscopy, after 72 h of nail lacquer application, revealed extensive distribution of the fluorescent tracer across the human nail plate in comparison to control that was confined to the top layer. Conclusively, an efficacious and stable nail lacquer of isotretinoin was developed for potential clinical topical use to target the drug to nail bed in treatment of nail psoriasis. PMID:25445993

  5. Matrix based system of isotretinoin as nail lacquer to enhance transungal delivery across human nail plate.

    PubMed

    Joshi, Monika; Sharma, Vijay; Pathak, Kamla

    2015-01-15

    The project was aimed at development of isotretinoin nail lacquer and assessment of its penetration efficiency across human nail plate. Preliminary studies (hydration enhancement factor and SEM) aided the selection of thioglycolic acid as permeation and eugenol was selected as local anesthetic in the formulation. The nail lacquer was optimized by 3(2) factorial design and a total of nine formulations were prepared and screened. In vitro adhesion and ex vivo permeation (cumulative drug permeation per unit area (CDP/A) = 6.61 ± 0.57 mg/cm(2)) across bovine hoof guided the selection of F3 as optimized formulation that was improvised. Viscosity adjustments to improve handling characteristics were affected by incorporation of ethyl cellulose (6%; F3M1) that scaled the viscosity to 312.681 cp and insignificantly (p > 0.05) affected CDP/A (6.32 ± 0.45 mg/cm(2)). In comparison to marketed preparation (Retino-A cream) F3M1 afforded two fold increase in CDP/A. The permeation characteristics were defined by Higuchi model (r(2) = 0.964) and flux value of 176 μg/cm(2)/h. Confocal laser scanning microscopy, after 72 h of nail lacquer application, revealed extensive distribution of the fluorescent tracer across the human nail plate in comparison to control that was confined to the top layer. Conclusively, an efficacious and stable nail lacquer of isotretinoin was developed for potential clinical topical use to target the drug to nail bed in treatment of nail psoriasis.

  6. Optimum exposure conditions for computed radiography depending on fixed pattern noise and efficiency of imaging plate-scanner systems

    SciTech Connect

    Ewert, U.; Heyne, K.; Zscherpel, U.; Jechow, M.; Bavendiek, K.

    2011-06-23

    The presently active standards on Computed Radiography (CR) need a major revision. It was observed by many users that the image quality for class B of EN 14784-2 is not achievable under the same exposure conditions as used for film exposure. A mathematical model was developed and tested, which allows the calculation of the image quality, proven by image quality indicators (IQI), depending on the fixed pattern noise and the efficiency of the used imaging plate (IP) scanner system. All tested IP scanner systems provide a fixed correlation between the measured signal/noise ratio (SNR) and the grey values in the digital images. The maximum achievable SNR{sub max} depends on the fixed pattern noise of the plate (high dose limit). Depending on the exposure dose an optimum visibility of IQIs can be predicted by calculation and measured considering the attenuation coefficient for calculation of the contrast/noise ratio (CNR). The diameter of the just visible wire is proportional to 1/sqrt(CNR). The optimum tube voltage for best visibility of IQIs and maximum CNR depend on the exposure dose. The optimum tube voltage for best visibility is achieved only at exposures with high dose. A dose dependant optimal tube voltage was not observed for film radiography.

  7. Ionospheric plasma flow about a system of electrically biased flat plates. M.S. Thesis - Cleveland State Univ. Final Report

    NASA Technical Reports Server (NTRS)

    Herr, Joel L.

    1993-01-01

    The steady state interaction of two electrically biased parallel plates immersed in a flowing plasma characteristic of low earth orbit is studied numerically. Fluid equations are developed to describe the motion of the cold positively charged plasma ions, and are solved using finite-differences in two dimensions on a Cartesian grid. The behavior of the plasma electrons is assumed to be described by the Maxwell-Boltzmann distribution. Results are compared to an analytical and a particle simulation technique for a simplified flow geometry consisting of a single semi-infinite negatively biased plate. Comparison of the extent of the electrical disturbance into the flowing plasma and the magnitude of the current collected by the plate is very good. The interaction of two equally biased parallel plates is studied as a function of applied potential. The separation distance at which the current collected by either plate decreases by five and twenty percent is determined as a function of applied potential. The percent decreases were based on a non-interacting case. The decrease in overall current is caused by a decrease in ionic density in the region between the plates. As the separation between the plates decreases, the plates collect the ions at a faster rate than they are supplied to the middle region by the oncoming plasma flow. The docking of spacecraft in orbit is simulated by moving two plates of unequal potential toward one another in a quasi-static manner. One plate is held at a large negative potential while the other floats electrically in the resulting potential field. It is found that the floating plate does not charge continuously negative as it approaches the other more negatively biased plate. Instead, it charges more and then less negative as ionic current decreases and then increases respectively upon approach. When the two plates come into contact, it is expected that the electrically floating plate will charge rapidly negative to a potential near that of

  8. Development of a robust Stokes flow solver: toward a global simulation of the plate-mantle system

    NASA Astrophysics Data System (ADS)

    Furuichi, M.; May, D.; Tackley, P. J.

    2010-12-01

    We are interested in the development of a numerical method for performing high resolution simulations of the coupled plate-mantle system, on massively parallel vector supercomputers (e.g. Earth Simulator 2). In order to treat a locally and highly varying viscosity, for example as would be expected between the upper mantle and tectonic plates and at a free surface implemented using a “sticky air” treatment, we have developed an iterative solution technique that is robust with respect to large viscosity jumps. Our solver design uses Schur complement reduction combined with a Krylov subspace method. To precondition the Schur complement, we employed a scaled BFBt preconditioner as a scalable approach against strong variations of viscosity. In addition, in order to improve the convergence of the Krylov subspace method for the momentum equations, we propose to use a mixed precision technique. We have implemented quad precision arithmetic by using the double-double precision method. Here we present results of a viscous falling block test to demonstrate the performance and robustness of our decoupled solver approach for problems with a large viscosity jump. We will also report on a preliminary study of a spherical Cartesian method using this solver design, which enables us to solve Stokes flow problems with self-gravitation and a free surface.

  9. Early results for treatment of three- and four-part fractures of the proximal humerus using the PHILOS plate system.

    PubMed

    Moonot, P; Ashwood, N; Hamlet, M

    2007-09-01

    Secure fixation of displaced proximal fractures of the humerus is a challenging problem. A total of 32 patients with acutely displaced three- or four-part proximal fractures of the humerus were treated by open reduction and internal fixation using the proximal humeral internal locking system (PHILOS) plate. There were 23 women and nine men with a mean age of 59.9 years (18 to 87). Data were collected prospectively and the outcomes were assessed using the Constant score. The mean follow-up was for 11 months (3 to 24). In 31 patients (97%) the fracture united clinically and radiologically at a mean of 10 weeks (8 to 24). The mean Constant score at final review was 66.5 (30 to 92). There was no significant difference in outcome when comparing patients aged more than 60 years (18 patients) with those aged less than 60 years (14 patients) (t-test, p = 0.8443). There was one case each of nonunion, malunion and a broken screw in the elderly population. This plate provides an alternative method of fixation for fractures of the proximal humerus. It provides a stable fixation in young patients with good-quality bone sufficient to permit early mobilisation. Failure of the screws to maintain fixation in the elderly remains a problem.

  10. Loads specification and embedded plate definition for the ITER cryoline system

    NASA Astrophysics Data System (ADS)

    Badgujar, S.; Benkheira, L.; Chalifour, M.; Forgeas, A.; Shah, N.; Vaghela, H.; Sarkar, B.

    2015-12-01

    ITER cryolines (CLs) are complex network of vacuum-insulated multi and single process pipe lines, distributed in three different areas at ITER site. The CLs will support different operating loads during the machine life-time; either considered as nominal, occasional or exceptional. The major loads, which form the design basis are inertial, pressure, temperature, assembly, magnetic, snow, wind, enforced relative displacement and are put together in loads specification. Based on the defined load combinations, conceptual estimation of reaction loads have been carried out for the lines located inside the Tokamak building. Adequate numbers of embedded plates (EPs) per line have been defined and integrated in the building design. The finalization of building EPs to support the lines, before the detailed design, is one of the major design challenges as the usual logic of the design may alter. At the ITER project level, it was important to finalize EPs to allow adequate design and timely availability of the Tokamak building. The paper describes the single loads, load combinations considered in load specification and the approach for conceptual load estimation and selection of EPs for Toroidal Field (TF) Cryoline as an example by converting the load combinations in two main load categories; pressure and seismic.

  11. Comparison of media in the Anaerobe-Tek and Presumpto plate systems and evaluation of the Anaerobe-Tek system for identification of commonly encountered anaerobes.

    PubMed

    Lombard, G L; Whaley, D N; Dowell, V R

    1982-12-01

    Using a variety of sporeforming and nonsporeforming anaerobic bacteria, we compared 10 differential agar media of the Anaerobe-Tek (A/T) system recently marketed by Flow Laboratories, Inc. (McLean, Va.) with 10 comparable media in Presumpto quadrant plates (Presumpto 1, 2, and 3) developed by the Centers for Disease Control Anaerobic Bacteria Branch. The A/T identification system was evaluated by comparing the species identity of anaerobes determined as recommended by the manufacturer's instruction manual with the identity of the strains obtained by the Centers for Disease Control Anaerobe Reference Laboratory by using conventional procedures. We also compared reactions obtained with the Presumpto plates with a chopped meat glucose broth culture as a source of inoculum with those obtained by using a turbid cell suspension from growth on blood agar as inoculum. The agreement of results for the 16 characteristics compared ranged from 92.8 to 100%. Comparison of test results obtained with 10 media in the Presumpto plate and A/T systems from the examination of 223 strains of anaerobes, representing 54 different taxa, showed the following agreement between A/T and CDC systems: catalase production, esculin hydrolysis, glucose fermentation, and lecithinase production (100%); inhibition of growth by bile agar (99.6%); lipase production (99%); DNase (98.7%); fermentation of lactose and mannitol (98.2%); starch hydrolysis (96.9%); gelatin hydrolysis (96.4%); and casein hydrolysis (94.6%). Of the 204 strains of common anaerobes tested with the A/T system, only 70% were correctly identified to the species level. However, several strains could have been identified correctly with the A/T system if data on certain other characteristics had been included in the A/T data base.

  12. Atomic mechanisms of. gamma. ' precipitate plate growth in the Al-Ag system

    SciTech Connect

    Howe, J.M.

    1985-03-01

    Energy-dispersive x-ray spectroscopy results that the precipitates have the composition Ag/sub 2/Al. High-resolution electron microscopy of ..gamma..' precipitates in both <110>//<1120> and <111>//<0001> orientations shows that all interfaces of the precipitate are largely coherent with the matrix and are faceted along low-energy (111) and (110) matrix plans, due to the influence of surface and elastic strain energies on the transformation. Further comparison between experimental and calculated high-resolution images of the precipitate/matrix interface and of Shockley partial dislocation ledges on the precipitate faces demonstrates that both thickening and lengthening of ..gamma..' precipitate plates occurs by the passage of the Shockley partial dislocations along alternate (111) matrix planes by a terrace-ledge-kink mechanism. These images and electron diffraction information also indicate that the ..gamma..' precipitates are ordered, where the A-planes in the precipitate contain nearly pure Ag and the B-planes have the composition Al/sub 2/Ag, and that the limiting reaction in the growth process is the substitutional diffusion of Ag cross kinks in the Shockley partial dislocations, which terminate in the Ag-rich A-planes. The terraces between ledges are atomically flat and ledges are uniformly stepped-down from the centers to the edges of isolated precipitates. Convergent-beam electron diffraction (CBED) analyses of ..gamma..' precipitates indicate that they have the space group P6/sub 3//mmc. Effect of specimen thickness on symmetry determinations by CBED was also examined for an ..cap alpha..-titanium sample. Results show that the symmetries observed in CBED patterns from thin specimens may be due to the limited thickness of the specimen, rather than to the actual space group of the material.

  13. Laser-assisted shearing of stainless steel and spring steel plates with the use of a laser scanner system - new hybrid production technology for the sheet metal industry

    NASA Astrophysics Data System (ADS)

    Emonts, Michael; Brecher, Christian

    The Fraunhofer IPT recently developed a new hybrid laser-assisted shearing process which enables conventional punching machines to produce punched sheared edges with continuous flush-cut surfaces in stainless steel plates (1.4301), spring steel plates (1.4310) and titanium alloy plates (3.7165). The new combination of localised laser-induced softening of the plate material in the shearing zone and the shearing process significantly reduces both process forces and process-related noise emissions. A modular system-upgrade for existing punching machines allows laser-assisted shearing to be implemented without the need for expensive new machine designs. The principle of the laser-assisted shearing process is based on briefly and selectively heating the material in the shearing zone via local absorption of laser radiation on the underside of the sheet metal plate before the punching tool comes into contact on the upper side of the metal plate. Laser-induced heating softens the material in the shearing zone within the material within a few tenths of a second. The laser-induced softening mechanisms also lead to a significant decrease of cutting forces as well as a reduction of tool wear, warping and noise emissions.

  14. Newly designed and validated impedance spectroscopy setup in microtiter plates successfully monitors viable biomass online.

    PubMed

    Luchterhand, Bettina; Nolten, Jannis; Hafizovic, Sadik; Schlepütz, Tino; Wewetzer, Sandra Janine; Pach, Elke; Meier, Kristina; Wandrey, Georg; Büchs, Jochen

    2015-08-01

    In microtiter plates, conventional online monitoring of biomass concentration based on optical measurements is limited to transparent media: It also cannot differentiate between dead or viable biomass or suspended particles. To address this limitation, this study introduces and validates a new online monitoring setup based on impedance spectroscopy for detecting only viable biomass in 48- and 96-well microtiter plates. The setup was first validated electronically and characterized by determining the cell constants of the measuring geometry. Defined cell suspensions of Ustilago maydis, Hansenula polymorpha, Escherichia coli and Bacillus licheniformis were characterized to find, among other parameters, the most suitable frequency range and the characteristic frequency of β-dispersion for each organism. Finally, the setup was exemplarily applied to monitor the growth of Hansenula polymorpha online. As reference, three different parallel cultures were performed in established cultivation systems. This new online monitoring setup based on impedance spectroscopy is robust and enables precise measurements of microbial biomass concentration. It is promising for future high-throughput applications.

  15. Upper plate deformation and seismic barrier in front of Nazca subduction zone: The Chololo Fault System and active tectonics along the Coastal Cordillera, southern Peru

    NASA Astrophysics Data System (ADS)

    Audin, Laurence; Lacan, Pierre; Tavera, Hernando; Bondoux, Francis

    2008-11-01

    The South America plate boundary is one of the most active subduction zone. The recent Mw = 8.4 Arequipa 2001 earthquake ruptured the subduction plane toward the south over 400 km and stopped abruptly on the Ilo Peninsula. In this exact region, the subduction seismic crisis induced the reactivation of continental fault systems in the coastal area. We studied the main reactivated fault system that trends perpendicular to the trench by detailed mapping of fault related-geomorphic features. Also, at a longer time scale, a recurrent Quaternary transtensive tectonic activity of the CFS is expressed by offset river gullies and alluvial fans. The presence of such extensional fault systems trending orthogonal to the trench along the Coastal Cordillera in southern Peru is interpreted to reflect a strong coupling between the two plates. In this particular case, stress transfer to the upper plate, at least along the coastal fringe, appears to have induced crustal seismic events that were initiated mainly during and after the 2001 earthquake. The seafloor roughness of the subducting plate is usually thought to be a cause of segmentation along subduction zones. However, after comparing and discussing the role of inherited structures within the upper plate to the subduction zone segmentation in southern Peru, we suggest that the continental structure itself may exert some feedback control on the segmentation of the subduction zone and thus participate to define the rupture pattern of major subduction earthquakes along the southern Peru continental margin.

  16. Digital Archive of UkrVO: first results of MAO NASU Solar System Bodies photographic plate processing

    NASA Astrophysics Data System (ADS)

    Ivanov, G.; Pakuliak, L.; Shatokhina, S.; Yizhakevych, E.; Kazantseva, L.; Andruk, V.

    The digitizing and processing of photographic plates with the images of the outer planets and their satellites from the archive collections of MAO NASU and AO of Kiev university included into the UkrVO Joint Digital Archive (JDA) have been made. Plates were obtained in the last half of the 20th century. The digitizing of JDA archive plates and inclusion of plate preview images into GPA database has been under way, using two models of flatbed scanners: Microtek ScanMaker 9800XL TMA and Epson Expression 10000XL. The database with metadata of plates is allocated on the computational resources of MAO NASU (http://gua.db.ukr-vo.org). Plates have been scanned at 16-bits grey dynamic range, with a resolution of 1200-1600 dpi, and saved in TIFF format. Linear dimensions of images are up to 13 thousand pixels (for plates 30.30 cm). The astrometric and photometric calibration procedures have been done in the LINUX-MIDASROMAFOT environment and Tycho-2 as reference with the image processing procedure specially developed for digitized images of huge linear dimensions on the basis of the image inherent traits. First results of digitized plate processing give the rms errors of 10 and 20 mas for RA, DEC respectively. (O-C) for plates with Pluto in comparison to JPL PLU021.DE405 has been derived of 140(RA) and 270(DEC) mas.

  17. Anatomy of an extinct magmatic system along a divergent plate boundary: Alftafjordur, Iceland

    NASA Astrophysics Data System (ADS)

    Urbani, S.; Trippanera, D.; Porreca, M.; Kissel, C.; Acocella, V.

    2015-08-01

    Recent rifting episodes highlight the role of magmatic systems with propagating dikes on crustal spreading. However, our knowledge of magmatic systems is usually limited to surface observations and geophysical data. Eastern Iceland allows direct access to extinct and eroded deeper magmatic systems. Here we collected field structural and AMS (anisotropy of magnetic susceptibility) data on 187 and 19 dikes, respectively, in the 10-12 Ma old Alftafjordur magmatic system. At a paleodepth of ~1.5 km, the extension due to diking is at least 1-2 orders of magnitude larger than that induced by regional tectonics, confirming magmatism as the key mechanism for crustal spreading. This magma-induced extension, inferred from the aspect ratio of the magmatic system, was of ~8 mm/yr, lower than the present one. AMS data suggest that most of dikes have geometrically normal fabric, at least at the margins, consistent with prevalent subvertical magma flow and propagation.

  18. A new method for analytical solution of inplane free vibration of rectangular orthotropic plates based on the analysis of infinite systems

    NASA Astrophysics Data System (ADS)

    Papkov, S. O.

    2016-05-01

    In this paper, a new method for in-plane free vibration analysis of rectangular orthotropic plate is presented. The cases for completely clamped and completely free plates are considered in detail. The boundary value problem is essentially reduced to infinite systems of linear algebraic equations. New mathematical theory and associated results are presented for investigating the asymptotic behavior of non-trivial solution of quasi-regular infinite system. By enhancing the theory, an effective and accurate algorithm for determining the natural frequencies and modes shapes vibrations is developed. The accuracy and computational efficiency of the method are demonstrated by examples.

  19. Multiple plate hydrostatic viscous damper

    NASA Technical Reports Server (NTRS)

    Ludwig, L. P. (Inventor)

    1981-01-01

    A device for damping radial motion of a rotating shaft is described. The damper comprises a series of spaced plates extending in a radial direction. A hydraulic piston is utilized to place a load in these plates. Each annular plate is provided with a suitable hydrostatic bearing geometry on at least one of its faces. This structure provides a high degree of dampening in a rotor case system of turbomachinery in general. The damper is particularly useful in gas turbine engines.

  20. Effect of different culture systems and 3, 5, 3'-triiodothyronine/follicle-stimulating hormone on preantral follicle development in mice.

    PubMed

    Zhang, Cheng; Wang, Xiaoxia; Wang, Zhengpin; Niu, Wanbao; Zhu, Baochang; Xia, Guoliang

    2013-01-01

    The mechanical method to isolate preantral follicle has been reported for many years. However, the culture systems in vitro are still unstable. The aim of this study was to analyze the effect of the culture system of mice preantral follicles on the follicular development in vitro. The results showed that the 96-well plate system was the most effective method for mice follicle development in vitro (volume change: 51.71%; survival rate: 89%, at day 4). Follicle-stimulating hormone (FSH) and Thyroid hormone (TH) are important for normal follicular development and dysregulation of hormones are related with impaired follicular development. To determine the effect of hormone on preantral follicular development, we cultured follicle with hormones in the 96-well plate culture system and found that FSH significantly increased preantral follicular growth on day 4. The FSH-induced growth action was markedly enhanced by T₃ although T₃ was ineffective alone. We also demonstrated by QRT-PCR that T₃ significantly enhanced FSH-induced up-regulation of Xiap mRNA level. Meanwhile, Bad, cell death inducer, was markedly down-regulated by the combination of hormones. Moreover, QRT-PCR results were also consistent with protein regulation which detected by Western Blotting analysis. Taken together, the findings of the present study demonstrate that 96-well plate system is an effective method for preantral follicle development in vitro. Moreover, these results provide insights on the role of thyroid hormone in increasing FSH-induced preantral follicular development, which mediated by up-regulating Xiap and down-regulating Bad.

  1. Use of a Slick-Plate as a Contingency Exercise Surface for the Treadmill With Vibration Isolation System

    NASA Technical Reports Server (NTRS)

    Loehr, James A.; Lee, Stuart M. C.; Schneider, Suzanne M.

    2003-01-01

    The treadmill with vibration isolation system (TVIS) was developed to counteract cardiovascular, musculoskeletal, and neurovestibular deconditioning during long-duration missions to the International Space Station (ISS). However, recent hardware failures have necessitated the development of a short-term, temporary contingency exercise countermeasure for TVIS until nominal operations could be restored. The purpose of our evaluation was twofold: 1) to examine whether a slick-plate/contingency exercise surface (CES) could be used as a walking/running surface and could elicit a heart rate (HR) greater than or equal to 70% HR maximum and 2) to determine the optimal hardware configuration, in microgravity, to simulate running/walking in a 1-g environment. One subject (male) participated in the slick surface evaluation and two subjects (one male, one female) participated in the microgravity evaluation of the slick surface configuration. During the slick surface evaluation, the subject was suspended in a parachute harness and bungee cord configuration to offset the subject#s body weight. Using another bungee cord configuration, we added a vertical load back to the subject, who was then asked to run for 20 minutes on the slick surface. The microgravity evaluation simulated the ISS TVIS, and we evaluated two different slick surfaces (Teflon surface and an aluminum surface coated with Tufram) for use as a CES. We evaluated each surface with the subject walking and running, with and without a handrail, and while wearing either socks or nylon booties over shoes. In the slick surface evaluation, the subject ran for 20 minutes and reached a maximum HR of 170 bpm. In the microgravity evaluation, the subjects chose the aluminum plate coated with Tufram as the CES, while wearing a pair of nylon booties over running shoes and using a handrail, as the optimal hardware configuration.

  2. Structural-acoustic model of a rectangular plate-cavity system with an attached distributed mass and internal sound source: Theory and experiment

    NASA Astrophysics Data System (ADS)

    Pirnat, Miha; Čepon, Gregor; Boltežar, Miha

    2014-03-01

    In this paper three approaches are combined to develop a structural-acoustic model of a rectangular plate-cavity system with an attached distributed mass and internal sound source. The first approach results from a recently presented analysis based on the Rayleigh-Ritz method and is used to circumvent the difficulties in obtaining the natural frequencies and mode shapes of a plate with an attached, distributed mass. Furthermore, different plate boundary conditions can be accommodated. The resulting mode shapes are defined as continuous functions; this is advantageous as they can be directly used in the second approach, i.e., the classic modal-interaction approach in order to obtain the coupled equations of the system. Finally, in the third approach a group of point sources emitting a pressure pulse in the time domain is used to model an internal sound source. For the validation of the developed model an experiment was conducted in two configurations using a simply supported aluminium plate and a clamped plate coupled with a plexiglas box containing a loudspeaker. Good agreement was found between the analytical and experimental data.

  3. Real-time ArcGIS and heterotrophic plate count based chloramine disinfectant control in water distribution system.

    PubMed

    Bai, Xiaohui; Zhi, Xinghua; Zhu, Huifeng; Meng, Mingqun; Zhang, Mingde

    2015-01-01

    This study investigates the effect of chloramine residual on bacteria growth and regrowth and the relationship between heterotrophic plate counts (HPCs) and the concentration of chloramine residual in the Shanghai drinking water distribution system (DWDS). In this study, models to control HPCs in the water distribution system and consumer taps are also developed. Real-time ArcGIS was applied to show the distribution and changed results of the chloramine residual concentration in the pipe system by using these models. Residual regression analysis was used to get a reasonable range of the threshold values that allows the chloramine residual to efficiently inhibit bacteria growth in the Shanghai DWDS; the threshold values should be between 0.45 and 0.5 mg/L in pipe water and 0.2 and 0.25 mg/L in tap water. The low residual chloramine value (0.05 mg/L) of the Chinese drinking water quality standard may pose a potential health risk for microorganisms that should be improved. Disinfection by-products (DBPs) were detected, but no health risk was identified.

  4. ELECTROMAGNETISM, OPTICS, ACOUSTICS, HEAT TRANSFER, CLASSICAL MECHANICS, AND FLUID DYNAMICS: On Feasibility of Variable Separation Method Based on Hamiltonian System for a Class of Plate Bending Equations

    NASA Astrophysics Data System (ADS)

    Eburilitu; Alatancang

    2010-03-01

    The eigenfunction system of infinite-dimensional Hamiltonian operators appearing in the bending problem of rectangular plate with two opposites simply supported is studied. At first, the completeness of the extended eigenfunction system in the sense of Cauchy's principal value is proved. Then the incompleteness of the extended eigenfunction system in general sense is proved. So the completeness of the symplectic orthogonal system of the infinite-dimensional Hamiltonian operator of this kind of plate bending equation is proved. At last the general solution of the infinite dimensional Hamiltonian system is equivalent to the solution function system series expansion, so it gives to theoretical basis of the methods of separation of variables based on Hamiltonian system for this kind of equations.

  5. Explicit modeling of composite plates and beams in the dynamics of multibody systems

    NASA Technical Reports Server (NTRS)

    Amirouche, F. M. L.; Ider, Sitki Kemal; Moumene, M.

    1989-01-01

    The state of the art dynamic response analysis of flexible multibody systems is currently restricted to elastic bodies with homogeneous materials. The requirements for high speed operation has made it necessary to use lightweight multi layered composite bodies in robotic systems and space structure applications. Dynamic modeling and analysis of such systems are particularly important since the effects of body flexibility to the performance are likely to be more pronounced. The eight-noded isoperimetric quadrilateral element with independent rotational and displacement degrees of freedom is extended to laminated composite elements. The element includes an arbitrary number of bonded layers, each of which may have a different thickness. The transverse shear deformation which is a predominant factor in the analysis of laminated composite structures is taken into account in developing the stiffness and mass matrices. The corresponding 3-D mode shapes are then incorporated to the multibody system dynamical equations. Floating body reference frames allow the selection of different boundary conditions, and the dynamical equations contain all the nonlinear interactions between the rigid and elastic motion. Example simulations are presented to illustrate the methods proposed.

  6. A fluid–structure interaction model to characterize bone cell stimulation in parallel-plate flow chamber systems

    PubMed Central

    Vaughan, T. J.; Haugh, M. G.; McNamara, L. M.

    2013-01-01

    Bone continuously adapts its internal structure to accommodate the functional demands of its mechanical environment and strain-induced flow of interstitial fluid is believed to be the primary mediator of mechanical stimuli to bone cells in vivo. In vitro investigations have shown that bone cells produce important biochemical signals in response to fluid flow applied using parallel-plate flow chamber (PPFC) systems. However, the exact mechanical stimulus experienced by the cells within these systems remains unclear. To fully understand this behaviour represents a most challenging multi-physics problem involving the interaction between deformable cellular structures and adjacent fluid flows. In this study, we use a fluid–structure interaction computational approach to investigate the nature of the mechanical stimulus being applied to a single osteoblast cell under fluid flow within a PPFC system. The analysis decouples the contribution of pressure and shear stress on cellular deformation and for the first time highlights that cell strain under flow is dominated by the pressure in the PPFC system rather than the applied shear stress. Furthermore, it was found that strains imparted on the cell membrane were relatively low whereas significant strain amplification occurred at the cell–substrate interface. These results suggest that strain transfer through focal attachments at the base of the cell are the primary mediators of mechanical signals to the cell under flow in a PPFC system. Such information is vital in order to correctly interpret biological responses of bone cells under in vitro stimulation and elucidate the mechanisms associated with mechanotransduction in vivo. PMID:23365189

  7. A fluid-structure interaction model to characterize bone cell stimulation in parallel-plate flow chamber systems.

    PubMed

    Vaughan, T J; Haugh, M G; McNamara, L M

    2013-04-01

    Bone continuously adapts its internal structure to accommodate the functional demands of its mechanical environment and strain-induced flow of interstitial fluid is believed to be the primary mediator of mechanical stimuli to bone cells in vivo. In vitro investigations have shown that bone cells produce important biochemical signals in response to fluid flow applied using parallel-plate flow chamber (PPFC) systems. However, the exact mechanical stimulus experienced by the cells within these systems remains unclear. To fully understand this behaviour represents a most challenging multi-physics problem involving the interaction between deformable cellular structures and adjacent fluid flows. In this study, we use a fluid-structure interaction computational approach to investigate the nature of the mechanical stimulus being applied to a single osteoblast cell under fluid flow within a PPFC system. The analysis decouples the contribution of pressure and shear stress on cellular deformation and for the first time highlights that cell strain under flow is dominated by the pressure in the PPFC system rather than the applied shear stress. Furthermore, it was found that strains imparted on the cell membrane were relatively low whereas significant strain amplification occurred at the cell-substrate interface. These results suggest that strain transfer through focal attachments at the base of the cell are the primary mediators of mechanical signals to the cell under flow in a PPFC system. Such information is vital in order to correctly interpret biological responses of bone cells under in vitro stimulation and elucidate the mechanisms associated with mechanotransduction in vivo.

  8. Cadmium plating replacements

    NASA Technical Reports Server (NTRS)

    Nelson, Mary J.; Groshart, Earl C.

    1995-01-01

    The Boeing Company has been searching for replacements to cadmium plate. Two alloy plating systems seem close to meeting the needs of a cadmium replacement. The two alloys, zinc-nickel and tin-zinc are from alloy plating baths; both baths are neutral pH. The alloys meet the requirements for salt fog corrosion resistance, and both alloys excel as a paint base. Currently, tests are being performed on standard fasteners to compare zinc-nickel and tin-zinc on threaded hardware where cadmium is heavily used. The Hydrogen embrittlement propensity of the zinc-nickel bath has been tested, and just beginning for the tin-zinc bath. Another area of interest is the electrical properties on aluminum for tin-zinc and will be discussed. The zinc-nickel alloy plating bath is in production in Boeing Commercial Airplane Group for non-critical low strength steels. The outlook is promising that these two coatings will help The Boeing Company significantly reduce its dependence on cadmium plating.

  9. Evaluation of the sensitivity and fading characteristics of an image plate system for x-ray diagnostics

    NASA Astrophysics Data System (ADS)

    Meadowcroft, A. L.; Bentley, C. D.; Stott, E. N.

    2008-11-01

    Image plates (IPs) are a reusable recording media capable of detecting ionizing radiation, used to diagnose x-ray emission from laser-plasma experiments. Due to their superior performance characteristics in x-ray applications [C. C. Bradford, W. W. Peppler, and J. T. Dobbins III, Med. Phys. 26, 27 (1999) and J. Digit. Imaging. 12, 54 (1999)], the Fuji Biological Analysis System (BAS) IPs are fielded on x-ray diagnostics for the HELEN laser by the Plasma Physics Department at AWE. The sensitivities of the Fuji BAS IPs have been absolutely calibrated for absolute measurements of x-ray intensity in the energy range of 0-100 keV. In addition, the Fuji BAS IP fading as a function of time was investigated. We report on the characterization of three Fuji BAS IP responses to x-rays using a radioactive source, and discrete x-ray line energies generated by the Excalibur soft x-ray facility and the Defense Radiological Standards Centre filter-fluorescer hard x-ray system at AWE.

  10. Ridge subduction sparked reorganization of the Pacific plate-mantle system 60-50 million years ago

    NASA Astrophysics Data System (ADS)

    Seton, Maria; Flament, Nicolas; Whittaker, Joanne; Müller, R. Dietmar; Gurnis, Michael; Bower, Dan J.

    2015-03-01

    A reorganization centered on the Pacific plate occurred ~53-47 million years ago. A "top-down" plate tectonic mechanism, complete subduction of the Izanagi plate, as opposed to a "bottom-up" mantle flow mechanism, has been proposed as the main driver. Verification based on marine geophysical observations is impossible as most ocean crust recording this event has been subducted. Using a forward modeling approach, which assimilates surface plate velocities and shallow thermal structure of slabs into mantle flow models, we show that complete Izanagi plate subduction and margin-wide slab detachment induced a major change in sub-Pacific mantle flow, from dominantly southward before 60 Ma to north-northeastward after 50 Ma. Our results agree with onshore geology, mantle tomography, and the inferred motion of the Hawaiian hot spot and are consistent with a plate tectonic process driving the rapid plate-mantle reorganization in the Pacific hemisphere between 60 and 50 Ma. This reorganization is reflected in tectonic changes in the Pacific and surrounding ocean basins.

  11. Micro-channel plate detector

    SciTech Connect

    Elam, Jeffrey W.; Lee, Seon W.; Wang, Hsien -Hau; Pellin, Michael J.; Byrum, Karen; Frisch, Henry J.

    2015-09-22

    A method and system for providing a micro-channel plate detector. An anodized aluminum oxide membrane is provided and includes a plurality of nanopores which have an Al coating and a thin layer of an emissive oxide material responsive to incident radiation, thereby providing a plurality of radiation sensitive channels for the micro-channel plate detector.

  12. Metal vapor arc ion plating

    SciTech Connect

    Bertram, L.A.; Fisher, R.W.; Mattox, D.M.; Zanner, F.J.

    1986-09-09

    A method and apparatus for ion plating are described. The apparatus uses more negative than a first electrode voltage in a vacuum arc remelt system to attract low energy ions from the anode electrode to the article to be plated. 2 figs.

  13. Analysis of a high-throughput cone-and-plate apparatus for the application of defined spatiotemporal flow to cultured cells.

    PubMed

    Spruell, Christopher; Baker, Aaron B

    2013-06-01

    The shear stresses derived from blood flow regulate many aspects of vascular and immunobiology. In vitro studies on the shear stress-mediated mechanobiology of endothelial cells have been carried out using systems analogous to the cone-and-plate viscometer in which a rotating, low-angle cone applies fluid shear stress to cells grown on an underlying, flat culture surface. We recently developed a device that could perform high-throughput studies on shear-mediated mechanobiology through the rotation of cone-tipped shafts in a standard 96-well culture plate. Here, we present a model of the three-dimensional flow within the culture wells with a rotating, cone-tipped shaft. Using this model we examined the effects of modifying the design parameters of the system to allow the device to create a variety of flow profiles. We first examined the case of steady-state flow with the shaft rotating at constant angular velocity. By varying the angular velocity and distance of the cone from the underlying plate we were able to create flow profiles with controlled shear stress gradients in the radial direction within the plate. These findings indicate that both linear and non-linear spatial distributions in shear stress can be created across the bottom of the culture plate. In the transition and "parallel shaft" regions of the system, the angular velocities needed to provide high levels of physiological shear stress (5 Pa) created intermediate Reynolds number Taylor-Couette flow. In some cases, this led to the development of a flow regime in which stable helical vortices were created within the well. We also examined the system under oscillatory and pulsatile motion of the shaft and demonstrated minimal time lag between the rotation of the cone and the shear stress on the cell culture surface. PMID:23280552

  14. Two-dimensional laser servoing for precision motion control of an ODV robotic license plate recognition system

    NASA Astrophysics Data System (ADS)

    Song, Zhen; Moore, Kevin L.; Chen, YangQuan; Bahl, Vikas

    2003-09-01

    As an outgrowth of series of projects focused on mobility of unmanned ground vehicles (UGV), an omni-directional (ODV), multi-robot, autonomous mobile parking security system has been developed. The system has two types of robots: the low-profile Omni-Directional Inspection System (ODIS), which can be used for under-vehicle inspections, and the mid-sized T4 robot, which serves as a ``marsupial mothership'' for the ODIS vehicles and performs coarse resolution inspection. A key task for the T4 robot is license plate recognition (LPR). For a successful LPR task without compromising the recognition rate, the robot must be able to identify the bumper locations of vehicles in the parking area and then precisely position the LPR camera relative to the bumper. This paper describes a 2D-laser scanner based approach to bumper identification and laser servoing for the T4 robot. The system uses a gimbal-mounted scanning laser. As the T4 robot travels down a row of parking stalls, data is collected from the laser every 100ms. For each parking stall in the range of the laser during the scan, the data is matched to a ``bumper box'' corresponding to where a car bumper is expected, resulting in a point cloud of data corresponding to a vehicle bumper for each stall. Next, recursive line-fitting algorithms are used to determine a line for the data in each stall's ``bumper box.'' The fitting technique uses Hough based transforms, which are robust against segmentation problems and fast enough for real-time line fitting. Once a bumper line is fitted with an acceptable confidence, the bumper location is passed to the T4 motion controller, which moves to position the LPR camera properly relative to the bumper. The paper includes examples and results that show the effectiveness of the technique, including its ability to work in real-time.

  15. Chest wall stabilization and reconstruction: short and long-term results 5 years after the introduction of a new titanium plates system

    PubMed Central

    Sollitto, Francesco; Loizzi, Domenico; Di Gennaro, Francesco; Scarascia, Daniele; Carlucci, Annalisa; Giudice, Giuseppe; Armenio, Andrea; Ludovico, Rossana; Loizzi, Michele

    2016-01-01

    Background We report short and long-term results with the dedicated Synthes® titanium plates system, introduced 5 years ago, for chest wall stabilization and reconstruction. Methods We retrospectively analyzed (January 2010 to December 2014) 27 consecutive patients (22 males, 5 females; range 16–83 years, median age 60 years), treated with this system: primary [3] and secondary [8] chest wall tumor; flail chest [5]; multiple ribs fractures [5]; sternal dehiscence-diastasis [3]; sternal fracture [1]; sternoclavicular joint dislocation [1]; Poland syndrome [1]. Short-term results were evaluated as: operating time, post-operative morbidity, mortality, hospital stay; long-term results as: survival, plates-related morbidity, spirometric values, chest pain [measured with Verbal Rating Scale (VRS) and SF12 standard V1 questionnaire]. Results Each patient received from 1 to 10 (median 2) titanium plates/splints; median operating time was 150 min (range: 115–430 min). Post-operative course: 15 patients (55.6%) uneventful, 10 (37%) minor complications, 2 (7.4%) major complications; no post-operative mortality. Median post-operative hospital stay was 13 days (range: 5–129 days). At a median follow-up of 20 months (range: 1–59 months), 21 patients (78%) were alive, 6 (22%) died. Three patients presented long-term plates-related morbidity: plates rupture [2], pin plate dislodgment [1]; two required a second surgical look. One-year from surgery median spirometric values were: FVC 3.31 L (90%), FEV1 2.46 L (78%), DLCO 20.9 mL/mmHg/min (76%). On 21 alive patients, 7 (33.3%) reported no pain (VRS score 0), 10 (47.6%) mild (score 2), 4 (19.1%) moderate (score 4), no-one severe (score >4); 15 (71.5%) reported none or mild, 6 (28.5%) moderate pain influencing quality of life. Conclusions An optimal chest wall stabilization and reconstruction was achieved with the Synthes® titanium plates system, with minimal morbidity, no post-operative mortality, acceptable operating time

  16. Deposition and survival of Escherichia coli O157:H7 on clay minerals in a parallel plate flow system.

    PubMed

    Cai, Peng; Huang, Qiaoyun; Walker, Sharon L

    2013-02-19

    Understanding bacterial pathogens deposition and survival processes in the soil-groundwater system is crucial to protect public health from soilborne and waterborne diseases. However, mechanisms of bacterial pathogen-clay interactions are not well studied, particularly in dynamic systems. Also, little is known about the viability of bacterial pathogens when attached to clays. In this study, a parallel plate flow system was used to determine the deposition kinetics and survival of Escherichia coli O157:H7 on montmorillonite, kaolinite, and goethite over a wide range of ionic strengths (IS) (0.1-100 mM KCl). E. coli O157:H7 deposition on the positively charged goethite is greater than that on the negatively charged kaolinite and montmorillonite. Although the zeta potential of kaolinite was more negative than that of montmorillonite, kaolinite showed a greater deposition for E. coli O157:H7 than montmorillonite, which is attributed to the chemical heterogeneity of clay minerals. Overall, increasing IS resulted in an increase of E. coli O157:H7 deposition on montmorillonite and kaolinite, and a decrease on goethite. Interaction energy calculations suggest that E. coli O157:H7 deposition on clays was largely governed by DLVO (Derjaguin-Landau-Verwey-Overbeek) forces. The loss of bacterial membrane integrity was investigated as a function of time using the Live/Dead BacLight viability assay. During the examined period of 6 h, E. coli O157:H7 retained its viability in suspension and when attached to montmorillonite and kaolinite; however, interaction with the goethite was detrimental. The information obtained in this study is of fundamental significance for the understanding of the fate of bacterial pathogens in soil environments.

  17. Production of long-strip multi-gap resistive plate chamber module for the STAR-MTD system

    NASA Astrophysics Data System (ADS)

    Chen, H.; Wang, Y.; Gonzalez-Diaz, D.; Wang, J.; Fan, X.; Cheng, J.; Li, Y.

    2012-10-01

    A new Long-strip Multi-gap Resistive Plate Chamber (LMRPC) prototype with 5 gas gaps has been developed for the Muon Telescope Detector (MTD) of the STAR experiment at RHIC in order to reduce the working High Voltage (HV) of previous design. Technical specifications related to the final infrastructure present in the experiment have motivated this effort. Its performance has been measured with cosmic rays. The efficiency of this prototype can reach 98% and the time resolution is around 95 ps. It shows a good uniformity among strips. The noise level is less than 0.2 Hz/cm2. The signal transmission and crosstalk of the modules was measured with a vector network analyzer, showing a good match with simulations within the amplifier bandwidth. A new cosmic-ray test system with long scintillators has been developed to accelerate the Quality Control (QC) process during the mass production of STAR-MTD. A selection of perpendicular cosmic-ray events for more accurate evaluation of the time resolution is achieved. The time resolution with this method is better, albeit with larger error, than the result obtained without any selection. A new spacer is used, resulting in a much reduced streamer ratio at comparable fields. Thirty-two modules have been built with the new spacer by the middle of April of 2012. They have been tested and they all have passed the QC.

  18. Fast imaging readout and electronics—a novel high-speed imaging system for micro-channel plates

    NASA Astrophysics Data System (ADS)

    Lapington, J. S.; Rees, K.

    2002-01-01

    The band-width of charge division readout anodes used with micro-channel plates (MCP) is usually limited by the speed of the acquisition electronics. We present a novel charge division anode that does not require analogue to digital conversion. The Fast Imaging Readout and Electronics is a new concept in high-speed imaging using an MCP detector. The imaging system described comprises an MCP intensifier coupled to a charge division image readout using high-speed, multichannel electronics. It has a projected spatial resolution of up to 128×128 pixels, though the image format is inherently flexible, and the potential for rates up to 100 million events per second with nanosecond timing resolution. The readout pattern has a planar electrode structure and the collected charge from each event is shared amongst all electrodes, grouped in pairs. The unique design of the readout obviates the need for charge measurement, usually the dominant process determining the event-processing deadtime. Instead, high-speed signal comparators, each of which act on the signals from an electrode pair, are used to define a binary code from which the position co-ordinate is directly mapped. We describe a proof of the concept of prototype anode and associated electronics using a novel application of very high-speed digital circuitry. We present preliminary results showing signal waveforms measured using a one-dimensional 16-pixel anode pattern.

  19. MHD Two-Fluid Flow and Heat Transfer between Two Inclined Parallel Plates in a Rotating System

    PubMed Central

    Sri Ramachandra Murty, P.; Balaji Prakash, G.

    2014-01-01

    Two-phase magnetohydrodynamic convective flow of electrically conducting fluid through an inclined channel is studied under the action of a constant transverse magnetic field in a rotating system. The fluids in the two phases are steady, incompressible, laminar, immiscible, and electrically conducting, having different densities, viscosities, and thermal and electrical conductivities. The transport properties of both the fluids are assumed constant. The bounding infinite inclined parallel plates are maintained at different constant temperatures, making an angle ϕ with the horizontal. Approximate solutions for velocity and temperature distributions are obtained by using a straightforward regular perturbation technique. An in-depth study has been done on the effects of rotation parameter, Hartmann number, inclination angle, the ratio of electrical conductivities, and viscosities of two fluids on the flow. It is observed that the effect of increasing rotation is to decrease the primary velocity. Further it is noticed that as the rotation increases, the secondary velocity increases for smaller rotation, while for larger rotation it decreases. It is also found that the temperature distribution decreases as the rotation increases. PMID:27351017

  20. Detection system for inclusion defects in hot-rolled steel plates using MFLT with two different magnetizing strengths

    NASA Astrophysics Data System (ADS)

    Yotsuji, Junichi; Koshihara, Takahiro

    2014-02-01

    Recently, steel can manufacturing requires higher quality because otherwise minute non-metallic inclusions in thin sheets cause cracks and result in a burst during pressurization after the pressing process. Quality testing systems have already been installed in the final process in steel plants, but if there were another inspection in an earlier step, for example, at the hot strip mill, the mass manufacture of nonconforming products could be avoided and maintaining quality control would be more efficient. In order to detect inclusion defects in hot-rolled steel plates, the authors developed a new technique for MFLT (Magnetic Flux Leakage Testing) using different magnetizing forces. According to an analysis of the noise factors in MFLT, it was found that the signals generated from the scale layer on a steel surface are dominant. A different magnetizing force method is the used to decrease this overpowering noise level in MFLT. In this paper, it was confirmed that inclusions larger than 160μm in diameter and less than 0.45mm in depth can be detected utilizing this method.

  1. Improved Thermal-Vacuum Compatible Flat Plate Radiometric Souce for System-Level Testing of Optical Sensors

    NASA Technical Reports Server (NTRS)

    Schwarz, Mark A.; Kent, Craig J.; Bousquet, Robert; Brown, Steven W.

    2015-01-01

    This work describes the development of an improved vacuum compatible flat plate radiometric source used for characterizing and calibrating remote optical sensors, in situ, throughout their testing period. The original flat plate radiometric source was developed for use by the VIIRS instrument during the NPOESS Preparatory Project (NPP). Following this effort, the FPI has had significant upgrades in order to improve both the radiometric throughput and uniformity. Results of the VIIRS testing with the reconfigured FPI are reported and discussed.

  2. Study on detecting spatial distribution of neutrons and gamma rays using a multi-imaging plate system.

    PubMed

    Tanaka, Kenichi; Sakurai, Yoshinori; Endo, Satoru; Takada, Jun

    2014-06-01

    In order to measure the spatial distributions of neutrons and gamma rays separately using the imaging plate, the requirement for the converter to enhance specific component was investigated with the PHITS code. Consequently, enhancing fast neutrons using recoil protons from epoxy resin was not effective due to high sensitivity of the imaging plate to gamma rays. However, the converter of epoxy resin doped with (10)B was found to have potential for thermal and epithermal neutrons, and graphite for gamma rays.

  3. Near Fault Observatories (NFO) services and integration plan for European Plate Observing System (EPOS) Implementation Phase

    NASA Astrophysics Data System (ADS)

    Chiaraluce, Lauro

    2016-04-01

    the services provided by other Thematic Core Services for the standard data (e.g. seismic and geodetic) and on the direct access to the e-infrastructures of individual NFOs via the Integrated Core Services web services for access and distribution of non standard data (e.g. strain- and tilt-meters, geochemical and electro- magneto-telluric data). We will collaborate with the other groups possessing the same data on data harmonization in terms of both format and metadata description to optimise and facilitate the integration and interoperability processes. The services will include a Virtual Laboratory, novel visualization tools for data and products describing the anatomy of active faults and the physical processes governing earthquake generation. VL is an online engagement and knowledge sharing initiative for communicating to the other scientists, stockholders and the public the state of scientific knowledge concerning earthquake source and tectonic processes generating catastrophic events. The availability of real-time data provides the unique opportunity of observing all phases of the earthquake rupture. It is thus of crucial importance developing methodologies to follow in real-time the evolution of the event (e.g. Earthquake Early Warning systems). NFOs are ideal infrastructures for hosting testing centers where a variety of scientific algorithms for real-time monitoring can be independently evaluated. Besides the interest for fundamental science, such developments have a societal impact and can attract new stakeholders such as industry partners who are interested in adopting in such (e.g. EEW) technologies.

  4. The European Plate Observing System (EPOS): Integrating Thematic Services for Solid Earth Science

    NASA Astrophysics Data System (ADS)

    Atakan, Kuvvet; Bailo, Daniele; Consortium, Epos

    2016-04-01

    The mission of EPOS is to monitor and understand the dynamic and complex Earth system by relying on new e-science opportunities and integrating diverse and advanced Research Infrastructures in Europe for solid Earth Science. EPOS will enable innovative multidisciplinary research for a better understanding of the Earth's physical and chemical processes that control earthquakes, volcanic eruptions, ground instability and tsunami as well as the processes driving tectonics and Earth's surface dynamics. Through integration of data, models and facilities EPOS will allow the Earth Science community to make a step change in developing new concepts and tools for key answers to scientific and socio-economic questions concerning geo-hazards and geo-resources as well as Earth sciences applications to the environment and to human welfare. EPOS, during its Implementation Phase (EPOS-IP), will integrate multidisciplinary data into a single e-infrastructure. Multidisciplinary data are organized and governed by the Thematic Core Services (TCS) and are driven by various scientific communities encompassing a wide spectrum of Earth science disciplines. These include Data, Data-products, Services and Software (DDSS), from seismology, near fault observatories, geodetic observations, volcano observations, satellite observations, geomagnetic observations, as well as data from various anthropogenic hazard episodes, geological information and modelling. In addition, transnational access to multi-scale laboratories and geo-energy test-beds for low-carbon energy will be provided. TCS DDSS will be integrated into Integrated Core Services (ICS), a platform that will ensure their interoperability and access to these services by the scientific community as well as other users within the society. This requires dedicated tasks for interactions with the various TCS-WPs, as well as the various distributed ICS (ICS-Ds), such as High Performance Computing (HPC) facilities, large scale data storage

  5. Multiplexed chemiluminescent assays in ArrayPlates for high-throughput measurement of gene expression

    NASA Astrophysics Data System (ADS)

    Martel, Ralph R.; Rounseville, Matthew P.; Botros, Ihab W.; Seligmann, Bruce E.

    2002-06-01

    Multiplexed Molecular Profiling (MMP) assays for drug discovery are performed in ArrayPlates. ArrayPlates are 96- well microtiter plates that contain a 16-element array at the bottom of each well. Each element within an array measures one analyte in a sample. A CCD imager records the quantitative chemiluminescent readout of all 1,536 elements in a 96-well plate simultaneously. Since array elements are reagent modifiable by the end-user, ArrayPlates can be adapted to a broad range of nucleic acid- and protein-based assays. Such multiplexed assays are rapidly established, flexible, robust, automation-friendly and cost-effective. Nucleic acid assays in ArrayPlates can detect DNA and RNA, including SNPs and ESTs. A multiplexed mRNA assay to measure the expression of 16 genes is described. The assay combines a homogeneous nuclease protection assay with subsequent probe immobilization to the array by means of a sandwich hybridization followed with chemiluminescent detection. This assay was used to examine cells grown and treated in microplates and avoided cloning, transfection, RNA insolation, reverse transcription, amplification and fluorochrome labeling. Standard deviations for the measurement of 16 genes ranged from 3 percent to 13 percent in samples of 30,000 cells. Such ArrayPlates transcription assays are useful in drug discovery and development for target validation, screening, lead optimization, metabolism and toxicity profiling. Chemiluminescent detection provides ArrayPlates assays with high signal-to-noise readout and simplifies imager requirements. Imaging a 2D surface that contains arrays simplifies lens requirements relative to imaging columns of liquid in microtiter plate wells. The Omix imager for ArrayPlates is described.

  6. A novel integration system of magnetically immobilized cells and a pair of graphite plate-stainless iron mesh electrodes for the bioremediation of coking wastewater.

    PubMed

    Jiang, Bei; Tan, Liang; Ning, Shuxiang; Shi, Shengnan

    2016-09-01

    Magnetically immobilized cells of Comamonas sp. JB coupling with electrode reaction was developed to enhance the treatment efficiency of coking wastewater containing phenol, carbazole (CA), dibenzofuran (DBF), and dibenzothiophene (DBT). The pair of graphite plate-stainless iron mesh electrodes was chosen as the most suitable electrodes. Magnetically immobilized cells coupling with graphite plate-stainless iron mesh electrodes (coupling system) exhibited high degradation activity for all the compounds, which were significantly higher than the sum by single magnetically immobilized cells and electrode reaction at the optimal voltage. Recycling experiments demonstrated that the degradation activity of coupling system increased gradually during eight recycles, indicating that there was a coupling effect between the biodegradation and electrode reaction. Phenol hydroxylase and qPCR assays confirmed that appropriate electrical stimulation could improve phenol hydroxylase activity and promote cells growth. Toxicity assessment suggested the treatment of the coking wastewater by coupling system led to less toxicity than untreated wastewater. PMID:27289060

  7. Downgoing plate controls on overriding plate deformation in subduction zones

    NASA Astrophysics Data System (ADS)

    Garel, Fanny; Davies, Rhodri; Goes, Saskia; Davies, Huw; Kramer, Stephan; Wilson, Cian

    2014-05-01

    Although subduction zones are convergent margins, deformation in the upper plate can be extensional or compressional and tends to change through time, sometimes in repeated episodes of strong deformation, e.g, phases of back-arc extension. It is not well understood what factors control this upper plate deformation. We use the code Fluidity, which uses an adaptive mesh and a free-surface formulation, to model a two-plate subduction system in 2-D. The model includes a composite temperature- and stress-dependent rheology, and plates are decoupled by a weak layer, which allows for free trench motion. We investigate the evolution of the state of stress and topography of the overriding plate during the different phases of the subduction process: onset of subduction, free-fall sinking in the upper mantle and interaction of the slab with the transition zone, here represented by a viscosity contrast between upper and lower mantle. We focus on (i) how overriding plate deformation varies with subducting plate age; (ii) how spontaneous and episodic back-arc spreading develops for some subduction settings; (iii) the correlation between overriding plate deformation and slab interaction with the transition zone; (iv) whether these trends resemble observations on Earth.

  8. Impact on plate waste of switching from a tray to a trayless delivery system in a university dining hall and employee response to the switch.

    PubMed

    Thiagarajah, Krisha; Getty, Victoria M

    2013-01-01

    A potential strategy for decreasing food waste in foodservice operations is trayless dining. The objective of this 2010 study was to compare the impact of using a tray vs a trayless system on plate waste and on employees' attitudes. To test the hypothesis that going trayless would reduce waste, liquid and solid plate waste were measured for 1 week with the then-existing tray system and again after a new trayless system was implemented in a buffet-style university dining hall serving roughly1,000 meals a day. Foodservice staff were invited to participate in a focus group about the impact on their jobs. The investigators calculated plate waste per patron under the two systems and used an independent samples t test to examine the significance of the difference. Comments from the focus group were analyzed for themes. A significant decrease in solid waste per patron (0.81 oz; P=0.001) was observed in switching from the tray to the trayless system (4.39 ± 0.24 oz vs 3.58 ± 0.08 oz per patron). A nonsignificant reduction was observed with liquid waste (49.77 ± 2.62 mL vs 46.36 ± 4.51 mL; P=0.18). Most of the employees preferred the trayless system as long as it did reduce waste, but felt that increased breakage of dishware and increased need to wipe down tables were possible concerns resulting from the switch. This study demonstrates that trayless dining can reduce plate waste, and that employees can be supportive of the change.

  9. Large-scale right-slip displacement on the East San Francisco Bay Region fault system, California: Implications for location of late Miocene to Pliocene Pacific plate boundary

    USGS Publications Warehouse

    McLaughlin, R.J.; Sliter, W.V.; Sorg, D.H.; Russell, P.C.; Sarna-Wojcicki, A. M.

    1996-01-01

    A belt of northwardly younging Neogene and Quaternary volcanic rocks and hydrothermal vein systems, together with a distinctive Cretaceous terrane of the Franciscan Complex (the Permanente terrane), exhibits about 160 to 170 km of cumulative dextral offset across faults of the East San Francisco Bay Region (ESFBR) fault system. The offset hydrothermal veins and volcanic rocks range in age from .01 Ma at the northwest end to about 17.6 Ma at the southeast end. In the fault block between the San Andreas and ESFBR fault systems, where volcanic rocks are scarce, hydrothermal vein system ages clearly indicate that the northward younging thermal overprint affected these rocks beginning about 18 Ma. The age progression of these volcanic rocks and hydrothermal vein systems is consistent with previously proposed models that relate northward propagation of the San Andreas transform to the opening of an asthenospheric window beneath the North American plate margin in the wake of subducting lithosphere. The similarity in the amount of offset of the Permanente terrane across the ESFBR fault system to that derived by restoring continuity in the northward younging age progression of volcanic rocks and hydrothermal veins suggests a model in which 80-110 km of offset are taken up 8 to 6 Ma on a fault aligned with the Bloomfield-Tolay-Franklin-Concord-Sunol-Calaveras faults. An additional 50-70 km of cumulative slip are taken up ??? 6 Ma by the Rogers Creek-Hayward and Concord-Franklin-Sunol-Calaveras faults. An alternative model in which the Permanente terrane is offset about 80 km by pre-Miocene faults does not adequately restore the distribution of 8-12 Ma volcanic rocks and hydrothermal veins to a single northwardly younging age trend. If 80-110 km of slip was taken up by the ESFBR fault system between 8 and 6 Ma, dextral slip rates were 40-55 mm/yr. Such high rates might occur if the ESFBR fault system rather than the San Andreas fault acted as the transform margin at this time

  10. SAMI Automated Plug Plate Configuration

    NASA Astrophysics Data System (ADS)

    Lorente, N. P. F.; Farrell, T.; Goodwin, M.

    2013-10-01

    The Sydney-AAO Multi-object Integral field spectrograph (SAMI) is a prototype wide-field system at the Anglo-Australian Telescope (AAT) which uses a plug-plate to mount its 13×61-core imaging fibre bundles (hexabundles) in the optical path at the telescope's prime focus. In this paper we describe the process of determining the positions of the plug-plate holes, where plates contain three or more stacked observation configurations. The process, which up until now has involved several separate processes and has required significant manual configuration and checking, is now being automated to increase efficiency and reduce error. This is carried out by means of a thin Java controller layer which drives the configuration cycle. This layer controls the user interface and the C++ algorithm layer where the plate configuration and optimisation is carried out. Additionally, through the Aladin display package, it provides visualisation and facilitates user verification of the resulting plates.

  11. Motion on upper-plate faults during subduction zone earthquakes: Case of the Atacama Fault System, northern Chile

    NASA Astrophysics Data System (ADS)

    Loveless, J. P.; Pritchard, M. E.

    2008-12-01

    Motion on the Atacama Fault System (AFS) in northern Chile is driven by Andean subduction zone processes. We use two approaches, observational and theoretical, to evaluate how the AFS and other forearc faults responded to coseismic stress induced by one well-studied megathrust earthquake, the 1995 Mw = 8.1 Antofagasta event. We use synthetic aperture radar interferometry (InSAR) to search for small-scale coseismic and postseismic deformation on individual faults. The InSAR data are ambiguous: some images show offset consistent with coseismic faulting on the Paposo segment of the AFS and others lack such signal. The fact that we do not observe the fault-like displacement in all coseismic interferograms suggests that atmospheric contamination, not tectonic deformation, is responsible for the signal. To explore the capacity of the earthquake to trigger motion on upper plate faults, we use seven published slip maps constrained by geodetic and/or seismic data to calculate static and dynamic Coulomb stress change (CSC) on faults in the Antofagasta region. The static CSC field varies between models and depends on the distribution of coseismic interplate slip. On the basis of the CSC distribution predicted by our preferred model constrained by all available data, we suggest it was unlikely that the Antofagasta earthquake directly triggered normal motion on the AFS, and the InSAR data are consistent with this null result. Field reports of normal faulting related to the earthquake may reflect recent (but not coseismic) motion or highly localized behavior not representative of the regional coseismic stress field.

  12. Improved Thermal-Vacuum Compatible Flat Plate Radiometric Source For System-Level Testing Of Optical Sensors

    NASA Technical Reports Server (NTRS)

    Schwarz, Mark A.; Kent, Craig J.; Bousquet, Robert; Brown, Steven W.

    2016-01-01

    In this work, we describe an improved thermal-vacuum compatible flat plate radiometric source which has been developed and utilized for the characterization and calibration of remote optical sensors. This source is unique in that it can be used in situ, in both ambient and thermal-vacuum environments, allowing it to follow the sensor throughout its testing cycle. The performance of the original flat plate radiometric source was presented at the 2009 SPIE1. Following the original efforts, design upgrades were incorporated into the source to improve both radiometric throughput and uniformity. The pre-thermal-vacuum (pre-TVAC) testing results of a spacecraft-level optical sensor with the improved flat plate illumination source, both in ambient and vacuum environments, are presented. We also briefly discuss potential FPI configuration changes in order to improve its radiometric performance.

  13. Plating versus intramedullary fixation for mid-shaft clavicle fractures: a systemic review and meta-analysis.

    PubMed

    Gao, Yan; Chen, Wei; Liu, Yue-Jv; Li, Xu; Wang, Hai-Li; Chen, Zhao-Yu

    2016-01-01

    Background. Plate fixation and intramedullary fixation are the most commonly used surgical treatment options for mid-shaft clavicle fractures; the latter method has demonstrated better performance in some studies. Objectives. Our aim was to critically review and summarize the literature comparing the outcomes of mid-shaft clavicle fracture treatment with plate fixation or intramedullary fixation to identify the better approach. Search Methods. Potential academic articles were identified from the Cochrane Library, MEDLINE (1966-2015.5), PubMed (1966-2015.5), EMBASE (1980-2015.5) and ScienceDirect (1966-2015.5). Gray studies were identified from the references of the included literature. Selection Criteria. Randomized controlled trials (RCTs) and non-RCTs comparing plate fixation and intramedullary fixation for mid-shaft clavicle fracture were included. Data Collection and Analysis. Two reviewers performed independent data abstraction. The I (2) statistic was used to assess heterogeneity. A fixed- or random-effects model was used for the meta-analysis. Results. Six RCTs and nine non-RCTs were retrieved, including 513 patients in the intramedullary fixation group and 521 patients in the plating group. No significant differences in terms of the union rate and shoulder function were found between the groups. Patients in the intramedullary fixation group had a shorter operative time, less blood loss, smaller wound size, and shorter union time than those in the plating group. With respect to complications, significant differences were identified for all complications and major complications (wound infection, nonunion, implant failures, transient brachial plexopathy, and pain after 6 months). Similar secondary complications (symptomatic hardware, hardware irritation, prominence, numbness, hypertrophic callus) were observed in both groups. Conclusions. Intramedullary fixation may be superior to plate fixation in the treatment of mid-shaft clavicle fractures, with similar

  14. Corrugated cover plate for flat plate collector

    DOEpatents

    Hollands, K. G. Terry; Sibbitt, Bruce

    1978-01-01

    A flat plate radiant energy collector is providing having a transparent cover. The cover has a V-corrugated shape which reduces the amount of energy reflected by the cover away from the flat plate absorber of the collector.

  15. Thermal protection system gap heating rates of the Rockwell International flat plate heat transfer model (OH2A/OH2B)

    NASA Technical Reports Server (NTRS)

    Foster, T. F.; Lockman, W. K.; Grifall, W. J.

    1973-01-01

    Heat transfer data for the Rockwell International Flat Plate Thermocouple Model are presented. The model simulated the Space Shuttle Vehicle Thermal Protection System. Data were recorded for locations in and around various size gaps for various gap orientation configurations. The test was conducted at Mach 5.1 for free-stream Reynolds number per foot values from 500,000 to 1,500,000.

  16. FIZICS: fluorescent imaging zone identification system, a novel macro imaging system.

    PubMed

    Skwish, Stephen; Asensio, Francisco; King, Greg; Clarke, Glenn; Kath, Gary; Salvatore, Michael J; Dufresne, Claude

    2004-12-01

    Constantly improving biological assay development continues to drive technological requirements. Recently, a specification was defined for capturing white light and fluorescent images of agar plates ranging in size from the NUNC Omni tray (96-well footprint, 128 x 85 mm) to the NUNC Bio Assay Dish (245 x 245 mm). An evaluation of commercially available products failed to identify any system capable of fluorescent macroimaging with discrete wavelength selection. To address the lack of a commercially available system, a custom imaging system was designed and constructed. This system provides the same capabilities of many commercially available systems with the added ability to fluorescently image up to a 245 x 245 mm area using wavelengths in the visible light spectrum.

  17. In vivo degradation of magnesium plate/screw osteosynthesis implant systems: Soft and hard tissue response in a calvarial model in miniature pigs.

    PubMed

    Schaller, Benoit; Saulacic, Nikola; Imwinkelried, Thomas; Beck, Stefan; Liu, Edwin Wei Yang; Gralla, Jan; Nakahara, Ken; Hofstetter, Willy; Iizuka, Tateyuki

    2016-03-01

    Biodegradable magnesium plate/screw osteosynthesis systems were implanted on the frontal bone of adult miniature pigs. The chosen implant geometries were based on existing titanium systems used for the treatment of facial fractures. The aim of this study was to evaluate the in vivo degradation and tissue response of the magnesium alloy WE43 with and without a plasma electrolytic surface coating. Of 14 animals, 6 received magnesium implants with surface modification (coated), 6 without surface modification (uncoated), and 2 titanium implants. Radiological examination of the skull was performed at 1, 4, and 8 weeks post-implantation. After euthanasia at 12 and 24 weeks, X-ray, computed tomography, and microfocus computed tomography analyses and histological and histomorphological examinations of the bone/implant blocks were performed. The results showed a good tolerance of the plate/screw system without wound healing disturbance. In the radiological examination, gas pocket formation was found mainly around the uncoated plates 4 weeks after surgery. The micro-CT and histological analyses showed significantly lower corrosion rates and increased bone density and bone implant contact area around the coated screws compared to the uncoated screws at both endpoints. This study shows promising results for the further development of coated magnesium implants for the osteosynthesis of the facial skeleton.

  18. Synchrotron radiation protein data collection system using the newly developed Weissenberg camera and imaging plate for crystal structure analysis (abstract)

    NASA Astrophysics Data System (ADS)

    Sakabe, N.; Nakagawa, A.; Sasaki, K.; Sakabe, K.; Watanabe, N.; Kondo, H.; Shimomura, M.

    1989-07-01

    It has been an earnest desire of protein crystallographers to collect fast, accurate, high resolution diffraction data from protein crystals, preferably with exposure time as short as possible. In order to meet this challenge, a new type of Weissenberg camera has been developed for the recording of diffraction intensity from protein crystals using synchrotron radiation. The BL6A2 line has a plane-bending mirror designed by Y. Sato. The optical bench with triangular tilt-cut Si crystal monochromator was designed by N. Kamiya and was installed in the BL6A2 hutch. The Weissenberg camera was set on the 2θ arm of the optical bench. This camera can be used with Fuji Imaging Plate (IP) as an x-ray detector, and the reading out of the image from the IP is carried out by using BA100. The characterization of this system was carried out using the native crystal of chicken gizzard G-actin DNase I complex and its Yb3+, PCMB, indium, and FMA derivatives. Since these crystals are very sensitive for x rays, the resolution limit of the diffraction was 5 Å with a 4-circle diffractometer on a rotating anode x-ray generator (N. Sakabe et al., J. Biochem. 95, 887. This complex was crystallized in space group P2,2,2, with a=42.0, b=225.3, and c=77.4 Å. The data were collected with this system with the 430-mm radius cassette when Photon Factory was operated at 2.5 GeV and 270 mA and the wavelength λ=1.004 Å was chosen. In order to avoid overlapping of diffraction spots, oscillation angle range and coupling constant (degree/mm) were settled on the basis of simulation patterns of diffraction spots up to the maximum resolution to be measured considering the direction of the crystal axes, wavelength, radius of the camera, and mosaicness of the crystal. When the oscillation axis was a axis, the oscillation angle range was selected at either 10° (1°/mm) or 5° (0.5°/mm) depending on the density of reciprocal lattice points along the incident beam, and typical exposure time in each IP

  19. Coda Q and its Frequency Dependence in the Eastern Himalayan and Indo-Burman Plate Boundary Systems

    NASA Astrophysics Data System (ADS)

    Mitra, S.; Kumar, A.

    2015-12-01

    We use broadband waveform data for 305 local earthquakes from the Eastern Himalayan and Indo-Burman plate boundary systems, to model the seismic attenuation in NE India. We measure the decay in amplitude of coda waves at discreet frequencies (between 1 and 12Hz) to evaluate the quality factor (Qc) as a function of frequency. We combine these measurements to evaluate the frequency dependence of Qc of the form Qc(f)=Qof η, where Qo is the quality factor at 1Hz and η is the frequency dependence. Computed Qo values range from 80-360 and η ranges from 0.85-1.45. To study the lateral variation in Qo and η, we regionalise the Qc by combining all source-receiver measurements using a back-projection algorithm. For a single back scatter model, the coda waves sample an elliptical area with the epicenter and receiver at the two foci. We parameterize the region using square grids. The algorithm calculates the overlap in area and distributes Qc in the sampled grids using the average Qc as the boundary value. This is done in an iterative manner, by minimising the misfit between the observed and computed Qc within each grid. This process is repeated for all frequencies and η is computed for each grid by combining Qc for all frequencies. Our results reveal strong variation in Qo and η across NE India. The highest Qo are in the Bengal Basin (210-280) and the Indo-Burman subduction zone (300-360). The Shillong Plateau and Mikir Hills have intermediate Qo (~160) and the lowest Qo (~80) is observed in the Naga fold thrust belt. This variation in Qo demarcates the boundary between the continental crust beneath the Shillong Plateau and Mikir Hills and the transitional to oceanic crust beneath the Bengal Basin and Indo-Burman subduction zone. Thick pile of sedimentary strata in the Naga fold thrust belt results in the low Qo. Frequency dependence (η) of Qc across NE India is observed to be very high, with regions of high Qo being associated with relatively higher η.

  20. Kinematic model for out-of-sequence thrusting: Motion of two ramp-flat faults and the production of upper plate duplex systems

    NASA Astrophysics Data System (ADS)

    Pavlis, Terry L.

    2013-06-01

    Kinematic models developed here suggest a bewildering array of structural styles can be generated during out-of-sequence thrusting. Many of these structures would be difficult to distinguish from a normally stacked thrust sequence and the process can produce younger-on-older faults that could easily be misinterpreted as normal faults. This paper considers a small subset of this problem within a large model space by considering structures that develop along a pair of ramp-flat faults that are moving simultaneously, or sequentially. Motion on the lower ramp warps the structurally higher fault due to fault-bend folding and when the fault ruptures through the warp it transfers a horse to the upper hanging wall. Continuity of the process generates what is referred to here as an "upper plate duplex" to distinguish the structure from a conventional duplex. Kinematic parameters are developed for two models within this general problem: 1) a system with a fixed ramp in the lower thrust, overridden by an upper thrust; and 2) a double-duplex system where a conventional duplex develops along the lower fault at the same time as an upper plate duplex is formed along the upper fault. The theory is tested with forward models using 2D Move software and these tests indicate different families of structural styles form in association with relative scaling of ramp systems, slip-ratio between faults, and aspect ratios of horse blocks formed in the upper-plate duplex. A first-order result of the analysis is that an upper plate duplex can be virtually indistinguishable from a conventional duplex unless the trailing branch lines of the horses are exposed or imaged; a condition seldom met in natural exposures. Restoration of an upper-plate duplex produces counterintuitive fault geometry in the restored state, and thus, restorations of upper plate duplexes that erroneously assume a conventional duplex model would produce restored states that are seriously in error. In addition, in most of

  1. Plated wire memory subsystem

    NASA Technical Reports Server (NTRS)

    Carpenter, K. H.

    1974-01-01

    The design, construction, and test history of a 4096 word by 18 bit random access NDRO Plated Wire Memory for use in conjunction with a spacecraft input/output and central processing unit is reported. A technical and functional description is given along with diagrams illustrating layout and systems operation. Test data is shown on the procedures and results of system level and memory stack testing, and hybrid circuit screening. A comparison of the most significant physical and performance characteristics of the memory unit versus the specified requirements is also included.

  2. Peridinialean dinoflagellate plate patterns, labels and homologies

    USGS Publications Warehouse

    Edwards, L.E.

    1990-01-01

    Tabulation patterns for peridinialean dinoflagellate thecae and cysts have been traditionally expressed using a plate labelling system described by C.A. Kofoid in the early 1900's. This system can obscure dinoflagellate plate homologies and has not always been strictly applied. The plate-labelling system presented here introduces new series labels but incorporates key features and ideas from the more recently proposed systems of G.L. Eaton and F.J.R. Taylor, as modified by W.R. Evitt. Plate-series recognition begins with the cingulum (C-series) and proceeds from the cingulum toward the apex for the three series of the epitheca/epicyst and proceeds from the cingulum toward the antapex for the two series of the hypotheca/hypocyst. The epithecal/epicystal model consists of eight plates that touch the anterior margin of the cingulum (E-series: plates E1-E7, ES), seven plates toward the apex that touch the E-series plates (M-series: R, M1-M6), and up to seven plates near the apex that do not touch E-series plates (D-series: Dp-Dv). The hypothecal/hypocystal model consists of eight plates that touch the posterior margin of the cingulum (H-series: H1-H6,HR,HS) and three plates toward the antapex (T1-T3). Epithecal/epicystal tabulation patterns come in both 8- and 7- models, corresponding to eight and seven plates, respectively, in the E-series. Hypothecal/hypocystal tabulation patterns also come in both 8- and 7-models, corresponding to eight and seven plates, respectively, in the H-series. By convention, the 7-model epitheca/epicyst has no plates E1 and M1; the 7-model hypotheca/hypocyst has no plate H6. Within an 8-model or 7-model, the system emphasizes plates that are presumed to be homologous by giving them identical labels. I introduce the adjectives "monothigmate", "dithigmate," and "trithigmate" to designate plates touching one, two, and three plates, respectively, of the adjacent series. The term "thigmation" applies to the analysis of plate contacts between

  3. Sputtering and ion plating

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The proceedings of a conference on sputtering and ion plating are presented. Subjects discussed are: (1) concepts and applications of ion plating, (2) sputtering for deposition of solid film lubricants, (3) commercial ion plating equipment, (4) industrial potential for ion plating and sputtering, and (5) fundamentals of RF and DC sputtering.

  4. The contribution of the Volcano Observations Work Package to the implementation of the European Plate Observing System

    NASA Astrophysics Data System (ADS)

    Puglisi, Giuseppe

    2016-04-01

    The overall aim of the implementation phase of European Plate Observing System (EPOS) is to make the integrated platform operational in order to guarantee seamless access to the data provided by the European Solid Earth communities. The Volcano Observations Work Package (WP11) contributes to this objective by implementing a Thematic Core Service (TCS) which is planned to give access to the data and services provided by the European Volcano Observatories (VO) and some Volcanological Research Institutions (VRI; such as university departments, laboratories, etc.). Both types are considered as national research infrastructures (RI) which the TCS will integrate. Currently, monitoring networks on European volcanoes consist of thousands of stations or sites where volcanological parameters are continuously or periodically measured. These sites are equipped with instruments for geophysical (seismic, geodetic, gravimetric, electromagnetic), geochemical (volcanic plumes, fumaroles, groundwater, rivers, soils), environmental observations (e.g. meteorological and air quality parameters), as well as various prototypal monitoring systems (e.g. Doppler radars, ground based SAR). Across Europe several laboratories provide sample characterization (rocks, gases, isotopes, etc.), quasi-continuous analysis of space-borne data (SAR, thermal imagery, SO2 and ash), as well as high-performance computing facilities. All these RIs provide high-quality information (observations) on the current status of European volcanoes and the geodynamic background of the surrounding areas. The implementation of the Volcano Observations TCS will address technical as well as managerial issues, both considering the current heterogeneous state-of-the-art of the volcanological research infrastructures in Europe. Indeed, the current arrangement of individual VO and VRI is considered too fragmented to be considered as a unique distributed infrastructure. Therefore, the main effort in the framework of the EPOS

  5. The concept of locking plates.

    PubMed

    Cronier, P; Pietu, G; Dujardin, C; Bigorre, N; Ducellier, F; Gerard, R

    2010-05-01

    After a short historical review of locking bone plates since their inception more than a century ago to the success of the concept less than 15 years ago with today's plates, the authors present the main locking mechanisms in use. In the two broad categories - plates with fixed angulation and those with variable angulation - the screw head is locked in the plate with a locknut by screwing in a threaded chamber on the plate or by screwing through an adapted ring. The authors then provide a concrete explanation, based on simple mechanical models, of the fundamental differences between conventional bone plates and locking plates and why a locking screw system presents greater resistance at disassembly, detailing the role played by the position and number of screws. The advantages of epiphyseal fixation are then discussed, including in cases of mediocre-quality bone. For teaching purposes, the authors also present assembly with an apple fixed with five locking screws withstanding a 47-kg axial load with no resulting disassembly. The principles of plate placement are detailed for both the epiphysis and diaphysis, including the number and position of screws and respect of the soft tissues, with the greatest success assured by the minimally invasive and even percutaneous techniques. The authors then present the advantages of locking plates in fixation of periprosthetic fractures where conventional osteosynthesis often encounters limited success. Based on simplified theoretical cases, the economic impact in France of this type of implant is discussed, showing that on average it accounts for less than 10% of the overall cost of this pathology to society. Finally, the possible problems of material ablation are discussed as well as the means to remediate these problems.

  6. Development and testing of a multiwell plates absorbance reader for clinical analysis using inexpensive webcam

    NASA Astrophysics Data System (ADS)

    Castillo, Jimmy; Gutierrez, Hector; Vitta, Yosmery; Martinez, Mauro; Fernandez, Alberto

    2007-09-01

    Biochemical analysis and clinical tests like glucose, hemoglobin, cholesterol, iron, etc. are crucial for early illness diagnosis like diabetes, anemia and coronary deceases. These tests usually are done in state of the art instruments in well equipped laboratories in health centers. In some cases, these instruments are not portable, so they are not recommended for clinical field studies in remote areas. The present work shows a portable low-cost prototype of multi-well plates reader designed for clinical analysis. A Light Emission Diodes (LEDs) array is used as excitation source and an inexpensive webcam as detector. The light source illuminates the 96 well plates and the webcam take the image with 640x480 pixels. The data is acquired and processed by using a portable computer. 96 samples can be read including blanks and calibration standards simultaneously. Light absorption data are processed using a MatLab software designed in our laboratory to obtain calibration curves, standards lectures and samples concentration. The system was evaluated using different analytes series solutions: Neutral Red, Cooper (II) Ammonia Complex and Methyl Orange. The results shows that it is possible to measure few micro liters of solutions with adequate exactitude and precision of less than 3%. As possible analytical clinical application, iron determination was performed using Fe(III) Thiocyanate complex. This method is usually applied in serum samples analysis. The sensibility achieved with the proposed instrumentation configurations allows the analysis of iron in serum samples in the references values normal range (0.75 - 1.5 mg/L) in human.

  7. Measurement of spatial distribution of neutrons and gamma rays for BNCT using multi-imaging plate system.

    PubMed

    Tanaka, Kenichi; Sakurai, Yoshinori; Tanaka, Hiroki; Kajimoto, Tsuyoshi; Takata, Takushi; Takada, Jun; Endo, Satoru

    2015-12-01

    Quality assurance of the spatial distributions of neutrons and gamma rays was tried using imaging plates (IPs) and converters to enhance the beam components in the epithermal neutron mode of the Kyoto University Reactor. The converters used were 4mm thick epoxy resin with B4C at 6.85 weight-percent (wt%) (10)B for epithermal neutrons, and 3mm thick carbon for gamma rays. Results suggested that the IP signal does not need a sensitivity correction regardless of the incident radiation that produces it.

  8. Characteristics of Bending Parts of Metal Plates Using Ultrasonic Bending Systems with a Vibration Punch and a Vibration Die

    NASA Astrophysics Data System (ADS)

    Tsujino, Jiromaru; Ueoka, Tetsugi; Takiguchi, Kazuhiro; Satoh, Hajime; Takahashi, Kazumitsu

    1993-05-01

    Characteristics of ultrasonic vibration bending of pure aluminum and anticorrosive aluminum plates of 2.0 to 3.0 mm thickness are studied using a 19 kHz longitudinal vibration punch and a 27 kHz vibration die. With ultrasonic vibration, the springback angle decreases to zero under sufficient vibration amplitude, bending angle increases and marked improvement of bending surface condition is obtained. Hardness of the specimen and elongation of the bending surface decrease, and roughness of the bending surface is decreased by vibration. Radius of curvature of the bending part increased to about double that without vibration.

  9. Reduced hydrogen cadmium plating

    SciTech Connect

    Hoeller, T.; Ross, L. ); Varma, R. ); Agarwala, V.S. )

    1991-01-01

    This paper demonstrates the advantages of using a periodic reverse pulse plating method, incorporating a fast cathodic pulse which is separated from the subsequent anodic/cathodic pulses by a long rest period in producing silvery cadmium coatings on steel from aqueous fluoroborate electrolyte. Also, the deposition obtained by combination of pulse currents and turbulent electrolyte flow system (forced convection of electrolyte, Re {approximately} 20-25,000) result in a near hydrogen-free electrodeposition of fine- grained cadmium. This is confirmed by the determination of diffusible hydrogen by the electrochemical (Barnach Electrode) method.

  10. Computational Methods and Theoretical Results for the Ka-Band Array Feed Compensation System-Deformable Flat Plate Experiment at DSS 14

    NASA Astrophysics Data System (ADS)

    Imbriale, W. A.; Hoppe, D. J.

    1999-10-01

    This article documents the computational methods and theoretical results for the deformable flat plate (DFP), array feed compensation system (AFCS), monopulse tracking system, and combined AFCS--DFP used for compensating the gravity-induced distortions on the DSN's 70-m antenna. These systems were utilized in an experiment designed to verify gravity compensation and tracking performance of the 70-m antenna at 31.8--32.2 GHz (Ka-band). This experiment took place from November 1998 through February 1999 and consisted of both quasar and spacecraft observations. The theoretical results are compared with the experimental data. The analytical tools are also used to document and understand the characteristics of each system.

  11. Troubleshooting plated-wire memories

    NASA Technical Reports Server (NTRS)

    Baker, C. M.; Bright, T. M.; Constable, R. C.

    1979-01-01

    Faults in plated wire memories are identified and located from outside of system by applying electrical impulses and analyzing their reflectance in technique of Time-Domain Reflectometry (TDR). Intermittent faults are easier to find because memory system is not disturbed by probing or disassembly.

  12. Effect of inherited structures on strike-slip plate boundaries: insight from analogue modelling of the central Levant Fracture System, Lebanon

    NASA Astrophysics Data System (ADS)

    Ghalayini, Ramadan; Daniel, Jean-Marc; Homberg, Catherine; Nader, Fadi

    2015-04-01

    Analogue sandbox modeling is a tool to simulate deformation style and structural evolution of sedimentary basins. The initial goal is to test what is the effect of inherited and crustal structures on the propagation, evolution, and final geometry of major strike-slip faults at the boundary between two tectonic plates. For this purpose, we have undertaken a series of analogue models to validate and reproduce the structures of the Levant Fracture System, a major NNE-SSW sinistral strike-slip fault forming the boundary between the Arabian and African plates. Onshore observations and recent high quality 3D seismic data in the Levant Basin offshore Lebanon demonstrated that Mesozoic ENE striking normal faults were reactivated into dextral strike-slip faults during the Late Miocene till present day activity of the plate boundary which shows a major restraining bend in Lebanon with a ~ 30°clockwise rotation in its trend. Experimental parameters consisted of a silicone layer at the base simulating the ductile crust, overlain by intercalated quartz sand and glass sand layers. Pre-existing structures were simulated by creating a graben in the silicone below the sand at an oblique (>60°) angle to the main throughgoing strike-slip fault. The latter contains a small stepover at depth to create transpression during sinistral strike-slip movement and consequently result in mountain building similarly to modern day Lebanon. Strike-slip movement and compression were regulated by steady-speed computer-controlled engines and the model was scanned using a CT-scanner continuously while deforming to have a final 4D model of the system. Results showed that existing normal faults were reactivated into dextral strike-slip faults as the sinistral movement between the two plates accumulated. Notably, the resulting restraining bend is asymmetric and segmented into two different compartments with differing geometries. One compartment shows a box fold anticline, while the second shows an

  13. A Refined Shear Deformation Plate Theory

    NASA Astrophysics Data System (ADS)

    Liu, Yucheng

    2011-04-01

    An improved higher-order shear deformation theory of plates is presented in this paper. The theory is developed from the transverse shear deformation theory presented by Ambartsumian [11]. The present plate theory contains kinematics of higher-order displacement field of plates, a system of higher-order differential equilibrium equations in terms of the three generalized displacements of bending plates, and a system of boundary conditions at each edge of plate boundaries. The present shear deformation theory of plates is validated by applying it to solve torsional plates and simply supported plates. The obtained solutions using the present theory are compared with the solutions of other shear-deformation theories. A good agreement is achieved through these comparisons and the advantages of the present theory are clearly verified. The shear deformation plate theory presented here can be applied to the analysis of laminated composite plates to better predict their dynamic and static behaviors. The proposed theory should also be supplemented to the theory of finite element analysis for developing new shell elements.

  14. Earth's Decelerating Tectonic Plates

    SciTech Connect

    Forte, A M; Moucha, R; Rowley, D B; Quere, S; Mitrovica, J X; Simmons, N A; Grand, S P

    2008-08-22

    Space geodetic and oceanic magnetic anomaly constraints on tectonic plate motions are employed to determine a new global map of present-day rates of change of plate velocities. This map shows that Earth's largest plate, the Pacific, is presently decelerating along with several other plates in the Pacific and Indo-Atlantic hemispheres. These plate decelerations contribute to an overall, globally averaged slowdown in tectonic plate speeds. The map of plate decelerations provides new and unique constraints on the dynamics of time-dependent convection in Earth's mantle. We employ a recently developed convection model constrained by seismic, geodynamic and mineral physics data to show that time-dependent changes in mantle buoyancy forces can explain the deceleration of the major plates in the Pacific and Indo-Atlantic hemispheres.

  15. ASSEMBLY OF PARALLEL PLATES

    DOEpatents

    Groh, E.F.; Lennox, D.H.

    1963-04-23

    This invention is concerned with a rigid assembly of parallel plates in which keyways are stamped out along the edges of the plates and a self-retaining key is inserted into aligned keyways. Spacers having similar keyways are included between adjacent plates. The entire assembly is locked into a rigid structure by fastening only the outermost plates to the ends of the keys. (AEC)

  16. Accelerated plate tectonics.

    PubMed

    Anderson, D L

    1975-03-21

    The concept of a stressed elastic lithospheric plate riding on a viscous asthenosphere is used to calculate the recurrence interval of great earthquakes at convergent plate boundaries, the separation of decoupling and lithospheric earthquakes, and the migration pattern of large earthquakes along an arc. It is proposed that plate motions accelerate after great decoupling earthquakes and that most of the observed plate motions occur during short periods of time, separated by periods of relative quiescence.

  17. Efficient DNA sequencing on microtiter plates using dried reagents and Bst DNA polymerase.

    PubMed

    Earley, J J; Kuivaniemi, H; Prockop, D J; Tromp, G

    1993-01-01

    Sequenase, Taq DNA polymerase and Bst DNA polymerase were tested for sequencing of DNA on microtiter plates using dried down reagents. Several parameters were investigated to expedite the drying process while minimizing damage to the enzyme. Sequenase did not tolerate drying very well, and frequently generated sequences with weak signals and many sites of premature termination. With Taq DNA polymerase it was possible to obtain sequences of good quality. However, there was considerable variation of results between experiments and between batches of microtiter plates. Bst DNA polymerase generated sequences of excellent quality. It was stable for more than a week in dried-down state at -20 degrees C and at least overnight at room temperature. The method described here using Bst DNA polymerase is well suited for laboratory robots and workstations that typically employ 96-well microtiter plates. PMID:8173079

  18. Rotatable shear plate interferometer

    DOEpatents

    Duffus, Richard C.

    1988-01-01

    A rotatable shear plate interferometer comprises a transparent shear plate mounted obliquely in a tubular supporting member at 45.degree. with respect to its horizontal center axis. This tubular supporting member is supported rotatably around its center axis and a collimated laser beam is made incident on the shear plate along this center axis such that defocus in different directions can be easily measured.

  19. Plating Tank Control Software

    1998-03-01

    The Plating Tank Control Software is a graphical user interface that controls and records plating process conditions for plating in high aspect ratio channels that require use of low current and long times. The software is written for a Pentium II PC with an 8 channel data acquisition card, and the necessary shunt resistors for measuring currents in the millampere range.

  20. Stability of Propofol in Polystyrene-Based Tissue Culture Plates

    PubMed Central

    Sall, Jeffrey W.; Leong, Jason

    2013-01-01

    Propofol has been reported to have high stability in glass and relatively high stability up to 24 hours in polyvinyl chloride-based medical plastics. Recent publications have observed the effects of propofol on cells and tissues grown in culture. Many cell culture plastics are formulated from polystyrene but we could find little information on the stability of propofol exposed to these products. We observed very little change in the concentration of propofol diluted in cell culture medium over 24 hours when exposed to glass, but substantial loss of the drug when exposed to 96-well polystyrene cell culture plates. This decrease was most rapid in the first hour but continued until 24 hours. The type of plastic used in cell and tissue culture experiments with propofol may influence the results by increasing the apparent dose required to see an effect. PMID:23632056

  1. A microtiter-plate screening method for biofilm disinfection and removal.

    PubMed

    Pitts, Betsey; Hamilton, Martin A; Zelver, Nicholas; Stewart, Philip S

    2003-08-01

    A quantitative spectrophotometric method was developed to measure the removal and killing efficacy of antibiofilm agents. Biofilms of Pseudomonas aeruginosa or Staphylococcus epidermidis were grown in 96-well plates, treated with an agent, then stained with either the biomass indicator crystal violet or the respiratory indicator 5-cyano-2,3-ditolyl tetrazolium chloride. This rapid screening method is sensitive enough to elucidate concentration-response relationships as well as differences between species responses to treatments. Using these assays, agents can be ranked by their ability to remove or kill biofilm. PMID:12782382

  2. Beyond plate tectonics - Looking at plate deformation with space geodesy

    NASA Technical Reports Server (NTRS)

    Jordan, Thomas H.; Minster, J. Bernard

    1988-01-01

    The requirements that must be met by space-geodetic systems in order to constrain the horizontal secular motions associated with the geological deformation of the earth's surface are explored. It is suggested that in order to improve existing plate-motion models, the tangential components of relative velocities on interplate baselines must be resolved to an accuracy of less than 3 mm/yr. Results indicate that measuring the velocities between crustal blocks to + or - 5 mm/yr on 100-km to 1000-km scales can produce geologically significant constraints on the integrated deformation rates across continental plate-boundary zones such as the western United States.

  3. Angular shear plate

    SciTech Connect

    Ruda, Mitchell C.; Greynolds, Alan W.; Stuhlinger, Tilman W.

    2009-07-14

    One or more disc-shaped angular shear plates each include a region thereon having a thickness that varies with a nonlinear function. For the case of two such shear plates, they are positioned in a facing relationship and rotated relative to each other. Light passing through the variable thickness regions in the angular plates is refracted. By properly timing the relative rotation of the plates and by the use of an appropriate polynomial function for the thickness of the shear plate, light passing therethrough can be focused at variable positions.

  4. Multicolor printing plate joining

    NASA Technical Reports Server (NTRS)

    Waters, W. J. (Inventor)

    1984-01-01

    An upper plate having ink flow channels and a lower plate having a multicolored pattern are joined. The joining is accomplished without clogging any ink flow paths. A pattern having different colored parts and apertures is formed in a lower plate. Ink flow channels each having respective ink input ports are formed in an upper plate. The ink flow channels are coated with solder mask and the bottom of the upper plate is then coated with solder. The upper and lower plates are pressed together at from 2 to 5 psi and heated to a temperature of from 295 F to 750 F or enough to melt the solder. After the plates have cooled and the pressure is released, the solder mask is removed from the interior passageways by means of a liquid solvent.

  5. Geologically current plate motions

    NASA Astrophysics Data System (ADS)

    DeMets, Charles; Gordon, Richard G.; Argus, Donald F.

    2010-04-01

    We describe best-fitting angular velocities and MORVEL, a new closure-enforced set of angular velocities for the geologically current motions of 25 tectonic plates that collectively occupy 97 per cent of Earth's surface. Seafloor spreading rates and fault azimuths are used to determine the motions of 19 plates bordered by mid-ocean ridges, including all the major plates. Six smaller plates with little or no connection to the mid-ocean ridges are linked to MORVEL with GPS station velocities and azimuthal data. By design, almost no kinematic information is exchanged between the geologically determined and geodetically constrained subsets of the global circuit-MORVEL thus averages motion over geological intervals for all the major plates. Plate geometry changes relative to NUVEL-1A include the incorporation of Nubia, Lwandle and Somalia plates for the former Africa plate, Capricorn, Australia and Macquarie plates for the former Australia plate, and Sur and South America plates for the former South America plate. MORVEL also includes Amur, Philippine Sea, Sundaland and Yangtze plates, making it more useful than NUVEL-1A for studies of deformation in Asia and the western Pacific. Seafloor spreading rates are estimated over the past 0.78 Myr for intermediate and fast spreading centres and since 3.16 Ma for slow and ultraslow spreading centres. Rates are adjusted downward by 0.6-2.6mmyr-1 to compensate for the several kilometre width of magnetic reversal zones. Nearly all the NUVEL-1A angular velocities differ significantly from the MORVEL angular velocities. The many new data, revised plate geometries, and correction for outward displacement thus significantly modify our knowledge of geologically current plate motions. MORVEL indicates significantly slower 0.78-Myr-average motion across the Nazca-Antarctic and Nazca-Pacific boundaries than does NUVEL-1A, consistent with a progressive slowdown in the eastward component of Nazca plate motion since 3.16 Ma. It also

  6. MHD Heat Transfer in Two-Layered Flow of Conducting Fluids through a Channel Bounded by Two Parallel Porous Plates in a Rotating System

    NASA Astrophysics Data System (ADS)

    Linga Raju, T.; Neela Rao, B.

    2016-08-01

    The paper aims to analyze the heat transfer aspects of a two-layered fluid flow in a horizontal channel under the action of an applied magnetic and electric fields, when the whole system is rotated about an axis perpendicular to the flow. The flow is driven by a common constant pressure gradient in the channel bounded by two parallel porous insulating plates, one being stationary and the other one oscillatory. The fluids in the two regions are considered electrically conducting, and are assumed to be incompressible with variable properties, namely, different densities, viscosities, thermal and electrical conductivities. The transport properties of the two fluids are taken to be constant and the bounding plates are maintained at constant and equal temperature. The governing partial differential equations are then reduced to the ordinary linear differential equations by using a two-term series. The temperature distributions in both fluid regions of the channel are derived analytically. The results are presented graphically to discuss the effect on the heat transfer characteristics and their dependence on the governing parameters, i.e., the Hartmann number, Taylor number, porous parameter, and ratios of the viscosities, heights, electrical and thermal conductivities. It is observed that, as the Coriolis forces become stronger, i.e., as the Taylor number increases, the temperature decreases in the two fluid regions. It is also seen that an increase in porous parameter diminishes the temperature distribution in both the regions.

  7. Overriding Plate Deformation During Subduction Evolution

    NASA Astrophysics Data System (ADS)

    Davies, J. H.; Garel, F.; Davies, R.; Goes, S. D. B.

    2015-12-01

    Subduction dynamics has been widely studied in free subduction models, which document the important control of the downgoing plate. However, various models have shown how the overriding plate can influence subduction dynamics through its thermal structure, thickness and coupling. Using the code Fluidity we investigate overriding plate deformation in a 2-D thermo-mechanical model of the two-plate subduction system. We use Fluidity's adaptive mesh and free-surface formulation. The model includes a composite temperature- and stress-dependent rheology, and plates are decoupled by a weak layer, which allows for free trench motion. We focus on the evolution of the topography and state of stress in the overriding plate during the different phases of the subduction process: early stages of subduction, free-fall sinking in the upper mantle and interaction of the slab with the high-viscosity lower mantle.

  8. 49 CFR 236.779 - Plate, top.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Plate, top. 236.779 Section 236.779 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF... OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.779 Plate, top....

  9. 49 CFR 236.779 - Plate, top.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Plate, top. 236.779 Section 236.779 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF... OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.779 Plate, top....

  10. 49 CFR 236.779 - Plate, top.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Plate, top. 236.779 Section 236.779 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF... OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.779 Plate, top....

  11. 49 CFR 236.779 - Plate, top.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Plate, top. 236.779 Section 236.779 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF... OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.779 Plate, top....

  12. 49 CFR 236.779 - Plate, top.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Plate, top. 236.779 Section 236.779 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF... OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.779 Plate, top....

  13. Overview of the multilayer-Fresnel zone plate and the kinoform lens development at MPI for intelligent systems

    NASA Astrophysics Data System (ADS)

    Tunca Sanli, Umut; Keskinbora, Kahraman; Grévent, Corinne; Schütz, Gisela

    2015-05-01

    The ultimate goal of our research is to develop novel fabrication methods for high efficiency and high resolution X-ray optics. To this end, we have been pursuing the fabrication of several innovative diffractive/refractive optics designs. One such optic is the multilayer type Fresnel zone plate (ML-FZP). Our fabrication process relies on the atomic layer deposition (ALD) of two materials on a smooth glass fiber followed by a focused ion beam (FIB) based slicing and polishing. The ALD process allows much smaller outermost zone widths than the standard electron beam lithography based FZPs, meaning FZPs with potentially higher resolutions. Moreover, by depositing the multilayer on a cm long glass-fiber FZPs with very high optical thicknesses can be fabricated that can efficiently focus harder X-rays as well. A 21 nm half-pitch resolution was achieved using the ML-FZPs. Another optic we have been working on is the kinoform lens, which is a refractive/diffractive optic with a 100 % theoretical focusing efficiency. Their fabrication is usually realized by using approximate models which limit their success. Recently the fabrication of real kinoform lenses has been successfully realized in our lab via gray-scale direct-write ion beam lithography without any approximations. The lenses have been tested in the soft X-ray range achieving up to ~90 % of the calculated efficiency which indicates outstanding replication of the designed profile. Here we give an overview of our research and discuss the future challenges and opportunities for these optics.

  14. A sensitivity analysis of central flat-plate photovoltaic systems and implications for national photovoltaics program planning

    NASA Technical Reports Server (NTRS)

    Crosetti, M. R.

    1985-01-01

    The sensitivity of the National Photovoltaic Research Program goals to changes in individual photovoltaic system parameters is explored. Using the relationship between lifetime cost and system performance parameters, tests were made to see how overall photovoltaic system energy costs are affected by changes in the goals set for module cost and efficiency, system component costs and efficiencies, operation and maintenance costs, and indirect costs. The results are presented in tables and figures for easy reference.

  15. A Simple Class Exercise on Plate Tectonic Motion.

    ERIC Educational Resources Information Center

    Bates, Denis E. B.

    1990-01-01

    Presented is an activity in which students construct a model of plate divergence with two sheets of paper to show the separation of two continental plates in a system of spreading ridges and faults. Diagrams and procedures are described. (CW)

  16. Optics for People Stuck in Traffic: License Plates.

    ERIC Educational Resources Information Center

    Chagnon, Paul

    1995-01-01

    Explains the theory behind the working of Scotchlite, a retrodirective material used for coating automotive license plates, and the Ensure Imaging System that allows law enforcement officers to verify the authenticity of the plate. (JRH)

  17. Inherent Strength of the osteo-WEDGE(™) Bone Plate Locking System for Arthrodesis of the First Metatarsocuneiform Joint: A Biomechanical Study.

    PubMed

    Graham, Michael E; Chikka, Avanthi; Goel, Vijay K

    2016-01-01

    First metatarsocuneiform joint arthrodesis with a locking bone plate and screw system has been effectively used to correct metatarsus primus varus and instability of the first ray. The goal of the present cadaveric biomechanical study was to quantify and compare the inherent strength of the first metatarsocuneiform joint and surrounding bones fixated with the osteo-WEDGE(™) bone plate locking system (OW) with that of intact specimens. Fourteen fresh-frozen adult human cadaveric foot specimens consisting of the first metatarsal and medial cuneiform bones with intact joint capsules and ligaments were used. The OW was implanted in 7 of these specimens at the first metatarsal cuneiform joint (MCJ), and the remaining 7 specimens were left intact. Each of the specimens was then subjected to axial force to simulate dorsiflexion of the first metatarsal using a cantilever bending test setup. Load was applied on the plantar aspect of the first metatarsal head until failure of the construct. The mean load and bending moment on the first MCJ at failure for the implanted specimens were 119.98 ± 56.76 N and 5.57 ± 2.71 Nm, respectively. For the intact specimens, the mean load and bending moment on the first MCJ at failure were 107.93 ± 60.90 N and 6.07 ± 3.18 Nm, respectively. None of the specimens showed catastrophic failure within the physiologic loading limits. These results imply that the mechanical strength of the OW is comparable to that of intact specimens. Thus, the first MCJ and surrounding bones fixated with an OW should be able to effectively withstand the vertical ground reaction forces the same as intact specimens. PMID:26884262

  18. Plating methods, a survey

    NASA Technical Reports Server (NTRS)

    Berkowitz, J. B.; Emerson, N. H.

    1972-01-01

    Results are presented of a comprehensive search of the literature available, much of which has been generated by the research centers of NASA and its contractors, on plating and coating methods and techniques. Methods covered included: (1) electroplating from aqueous solutions; (2) electroplating from nonaqueous solutions; (3) electroplating from fused-salt baths; (4) electroforming; (5) electroless plating, immersion plating, and mirroring; (6) electroplating from gaseous plasmas; and (7) anodized films and conversion coatings.

  19. GOLD PLATING PROCESS

    DOEpatents

    Seegmiller, R.

    1957-08-01

    An improved bath is reported for plating gold on other metals. The composition of the plating bath is as follows: Gold cyanide from about 15 to about 50 grams, potassium cyanide from about 70 to about 125 grams, and sulfonated castor oil from about 0.1 to about 10 cc. The gold plate produced from this bath is smooth, semi-hard, and nonporous.

  20. PLATES WITH OXIDE INSERTS

    DOEpatents

    West, J.M.; Schumar, J.F.

    1958-06-10

    Planar-type fuel assemblies for nuclear reactors are described, particularly those comprising fuel in the oxide form such as thoria and urania. The fuel assembly consists of a plurality of parallel spaced fuel plate mennbers having their longitudinal side edges attached to two parallel supporting side plates, thereby providing coolant flow channels between the opposite faces of adjacent fuel plates. The fuel plates are comprised of a plurality of longitudinally extending tubular sections connected by web portions, the tubular sections being filled with a plurality of pellets of the fuel material and the pellets being thermally bonded to the inside of the tubular section by lead.

  1. Shock wave absorber having apertured plate

    DOEpatents

    Shin, Y.W.; Wiedermann, A.H.; Ockert, C.E.

    1983-08-26

    The shock or energy absorber disclosed herein utilizes an apertured plate maintained under the normal level of liquid flowing in a piping system and disposed between the normal liquid flow path and a cavity pressurized with a compressible gas. The degree of openness (or porosity) of the plate is between 0.01 and 0.60. The energy level of a shock wave travelling down the piping system thus is dissipated by some of the liquid being jetted through the apertured plate toward the cavity. The cavity is large compared to the quantity of liquid jetted through the apertured plate, so there is little change in its volume. The porosity of the apertured plate influences the percentage of energy absorbed.

  2. Shock wave absorber having apertured plate

    DOEpatents

    Shin, Yong W.; Wiedermann, Arne H.; Ockert, Carl E.

    1985-01-01

    The shock or energy absorber disclosed herein utilizes an apertured plate maintained under the normal level of liquid flowing in a piping system and disposed between the normal liquid flow path and a cavity pressurized with a compressible gas. The degree of openness (or porosity) of the plate is between 0.01 and 0.60. The energy level of a shock wave travelling down the piping system thus is dissipated by some of the liquid being jetted through the apertured plate toward the cavity. The cavity is large compared to the quantity of liquid jetted through the apertured plate, so there is little change in its volume. The porosity of the apertured plate influences the percentage of energy absorbed.

  3. Partial Melt Systems in Plate-Driven Corner Flow: Evaluating the Formation of Porosity Bands as a Mechanism for Magma Focusing at Mid-Ocean Ridges

    NASA Astrophysics Data System (ADS)

    Gebhardt, D.; Butler, S. L.

    2015-12-01

    The imposition of an external shear on a system of partial melt will result in compaction of the solid matrix and concentration of the interstitial liquid melt leading to the formation of regions of contrasting high and low porosity. In experiments, direct and torsional shear geometries have demonstrated that these regions of varying porosity form in bands orientated at low angles relative to the shear plane. A variety of numerical models have been employed to recreate these experimental results. Simple shear, pure shear and torsional shear geometries have been used in both linear and nonlinear numerical settings to model the formation of the porosity bands. In this contribution the numerical models utilize a shear geometry derived from the velocity field of the plate-driven corner flow of a mid-ocean ridge. Motivation for using the velocity field of a mid-ocean ridge comes from evidence that suggests the existence of lateral melt channeling from either side of the ridge axis. Imposing the shear from a mid-ocean ridge corner flow allows for the evaluation of the resulting porosity bands in terms of suitability for channeling melt laterally toward the ridge axis. This is done using both slow and fast spreading ridge geometries. The degree of similarity between previous numerical and experimental results has been found to be greatly influenced by the imposed viscosity law of the solid matrix phase. In order to keep this in mind, the numerical models in this contribution use three different matrix viscosity laws: strain-rate independent, strain-rate dependent and anisotropic. Of these rheologies, strain-rate independence results in the poorest orientation for channeling melt directly to the ridge axis. The strain-rate dependent and anisotropic viscosities present more favorable direct-channeling orientations for the fastest growing porosity bands, but in both cases the background flow will rotate bands to less ideal orientations over time. However, these less

  4. Exhumation History of an Oblique Plate Boundary: Investigating Kaikoura Mountain-building within the Marlborough Fault System, NE South Island New Zealand

    NASA Astrophysics Data System (ADS)

    Collett, C.; Duvall, A. R.; Flowers, R. M.; Tucker, G. E.

    2015-12-01

    The Kaikoura Mountains stand high as topographic anomalies in the oblique Pacific-Australian plate boundary zone known as the Marlborough Fault System (MFS), NE South Island New Zealand. The base of both the Inland and Seaward Kaikoura Ranges are bound on the SE by major, steeply NW-dipping, right lateral, active strike-slips (Clarence and Hope faults of the MFS, respectively). Previous geologic mapping, observations of predominantly horizontal fault slip at the surface from GPS and offset Quaternary deposits, and uplift of marine terraces, provide evidence for shortening and mountain-building via distributed deformation off of the main MFS strike-slip faults. However, quantitative estimates of the magnitude and spatial patterns of exhumation and of the timing of mountain-building in the Kaikouras are needed to understand more fully the nature of oblique deformation in the MFS. We present new apatite and zircon (U-Th)/He ages from opposite sides of the Hope and Clarence faults, spanning over 2 km of relief within the Kaikoura Mountains to identify spatial and temporal changes in exhumation rates in relation to the adjacent faults. Young (~3 Ma) apatite He ages and rapid (potentially > 1 mm/yr) exhumation rates from opposite sides of the faults are consistent with previously mentioned evidence of recent, regional, distributed deformation off of the main MFS faults. Moreover, early Miocene zircon He ages imply that parts of this region experienced an earlier phase of fault-related exhumation. Large changes in zircon He ages across the faults from ~20 Ma to > 100 Ma support hypotheses that portions of the Marlborough Faults may be re-activated, early Miocene thrusts. The zircon data are also consistent with the hypothesis of an early Miocene initiation of the oblique Pacific-Australian plate boundary in this region. Evidence for this comes from a change in sedimentation during this time from fine marine sediments to coarse, terrigenous conglomerates. Observing more

  5. Zone-plate-array lithography (ZPL): a maskless fast-turn-around system for microoptic device fabrication

    NASA Astrophysics Data System (ADS)

    Menon, Rajesh; Gil, Dario; Carter, David J. D.; Patel, Amil; Smith, Henry I.

    2003-01-01

    Ever-increasing demands of smaller feature sizes and larger throughputs have catapulted the semicondutor lithography juggernaut to develop immensely complex and expensive systems. However, it is not clear if the lithography needs for microoptic and other "botique" device fabrication are being addressed. ZPAL is a new nanolithography technique which leverages advances in micromechanics and diffractive optics technologies. We present ZPAL as the ideal system for such non-conventional lithography needs.

  6. Unsteady two-layered fluid flow of conducting fluids in a channel between parallel porous plates under transverse magnetic field in a rotating system

    NASA Astrophysics Data System (ADS)

    Linga Raju, T.; Neela Rao, B.

    2016-05-01

    An unsteady MHD two-layered fluid flow of electrically conducting fluids in a horizontal channel bounded by two parallel porous plates under the influence of a transversely applied uniform strong magnetic field in a rotating system is analyzed. The flow is driven by a common constant pressure gradient in a channel bounded by two parallel porous plates, one being stationary and the other oscillatory. The two fluids are assumed to be incompressible, electrically conducting with different viscosities and electrical conductivities. The governing partial differential equations are reduced to the linear ordinary differential equations using two-term series. The resulting equations are solved analytically to obtain exact solutions for the velocity distributions (primary and secondary) in the two regions respectively, by assuming their solutions as a combination of both the steady state and time dependent components of the solutions. Numerical values of the velocity distributions are computed for different sets of values of the governing parameters involved in the study and their corresponding profiles are also plotted. The details of the flow characteristics and their dependence on the governing parameters involved, such as the Hartmann number, Taylor number, porous parameter, ratio of the viscosities, electrical conductivities and heights are discussed. Also an observation is made how the velocity distributions vary with the rotating hydromagnetic interaction in the case of steady and unsteady flow motions. The primary velocity distributions in the two regions are seen to decrease with an increase in the Taylor number, but an increase in the Taylor number causes a rise in secondary velocity distributions. It is found that an increase in the porous parameter decreases both the primary and secondary velocity distributions in the two regions.

  7. Alteration of the aPA ELISA by UV exposure of polystyrene microtiter plates.

    PubMed

    Goldberg, J S; Wagenknecht, D R; McIntyre, J A

    1996-01-01

    Interlaboratory inconsistencies in antiphospholipid antibody (aPA) solid phase assays have prompted controversy in clinical laboratory testing for aPA. We found that the aPA ELISA can be influenced by the type of microtiter plate utilized and by the conditions in which the plates are stored. By exposing 96-well, flat-bottom polystyrene microtiter plates to short wave UV light (254 nm), the aPA ELISA signal decreased in a UV dose-dependent manner. No effect was seen with long wave UV light (366 nm). These results were independent of the antibody isotype under study or the phospholipid (PL) antigen used: anionic phosphatidylserine (PS) and cardiolipin (CL), or zwitterionic phosphatidylethanolamine (PE). Purified human beta 2-glycoprotein I (beta 2 GPI), a known cofactor for anionic PL, and rabbit anti-beta 2 GPI antisera were used to demonstrate that beta 2 GPI bound equally to UV treated and untreated microtiter plates. In contrast, recognition of beta 2 GPI on an anionic PL surface was decreased on UV treated plates, suggesting that UV exposure alters the lipid binding properties of the microliter plate. To determine whether UV exposure inhibited PL binding directly or caused a change in the way the PL was bound, the amount of PL bound to UV treated and untreated plates was measured by using fluorescent labeled PS and a fluorimeter. PS binding was decreased by 53% in UV treated wells as compared to untreated wells. These data show that short wave UV exposure reduces PL binding to polystyrene microtiter plates, thereby reducing the amount of beta 2 GPI bound to PL coated ELISA plates. Thus by using UV exposed microtiter plates, decreased or false-negative a PA ELISA results may be obtained for aPA positive plasmas. PMID:8887002

  8. Earthquakes and plate tectonics

    USGS Publications Warehouse

    Spall, H.

    1977-01-01

    An explanation is to be found in plate tectonics, a concept which has revolutionized thinking in the Earth sciences in the last 10 years. The theory of plate tectonics combines many of the ideas about continental drift (originally proposed in 1912 by Alfred Wegener in Germany) and sea-floor spreading (suggested originally by Harry Hess of Princeton University). 

  9. Blue Willow Story Plates

    ERIC Educational Resources Information Center

    Fontes, Kris

    2009-01-01

    In the December 1997 issue of "SchoolArts" is a lesson titled "Blue Willow Story Plates" by Susan Striker. In this article, the author shares how she used this lesson with her middle-school students many times over the years. Here, she describes a Blue Willow plate painting project that her students made.

  10. Turbine vane plate assembly

    SciTech Connect

    Schiavo Jr., Anthony L.

    2006-01-10

    A turbine vane assembly includes a turbine vane having first and second shrouds with an elongated airfoil extending between. Each end of the airfoil transitions into a shroud at a respective junction. Each of the shrouds has a plurality of cooling passages, and the airfoil has a plurality of cooling passages extending between the first and second shrouds. A substantially flat inner plate and an outer plate are coupled to each of the first and second shrouds so as to form inner and outer plenums. Each inner plenum is defined between at least the junction and the substantially flat inner plate; each outer plenum is defined between at least the substantially flat inner plate and the outer plate. Each inner plenum is in fluid communication with a respective outer plenum through at least one of the cooling passages in the respective shroud.

  11. A new control and data acquisition system for cosmic ray telescopes based on multigap resistive plate chambers

    NASA Astrophysics Data System (ADS)

    Avanzini, C.; Bossini, E.; Paoletti, R.; Partini, S.; Pilo, F.; Tazzioli, A.

    2013-08-01

    The upcoming phase of expansion of the telescope network of the EEE project has recently inspired a proposal of redesign of the detector control and monitoring, as well as data acquisition interfaces. The new design results in a very compact and versatile system with a significant cost reduction. The system architecture is described, with emphasis on the integration of data acquisition, trigger and GPS into a single unit. Performances of a fully functional prototype are also reported, as well as plans for future developments.

  12. Importance of the Small-Scale Processes Melting, Plate Boundary Formation and Mineralogy on the Large-Scale, Long-Term Thermo-Chemical Evolution of Earth's Mantle-Plate System

    NASA Astrophysics Data System (ADS)

    Tackley, P.

    2015-12-01

    Seismic observations of the deep Earth reveal the presence of two large low shear velocity provinces (LLSVPs) that are typically inferred to be dense chemically-distinct material, as well as discontinuities that are typically linked to the post-perovskite (pPv) phase transition. Several possible origins of chemically-dense material have been proposed, including recycling of mid-ocean ridge basalt (MORB), primordial differentiation events, crystallisation of a basal magma ocean, or some combination of these creating a basal melange (BAM; Tackley 2012 Earth Sci. Rev.). Each of these possibilities would result in a different composition hence different mineralogy. In order to constrain this we have been running calculations of thermo-chemical mantle evolution over 4.5 billion years that include melting-induced differentiation, plate tectonics induced by strongly temperature-dependent viscosity and plastic yielding, core cooling and compressibility with reasonable assumptions about the pressure-dependence of other material properties. Some of our simulations start from a magma ocean state so initial layering is developed self-consistently. Already-published results (Nakagawa et al., 2009 GCubed, 2010 PEPI, 2012 GCubed) already indicate the importance of exact MORB composition on the amount of MORB segregating above the CMB, which in turn influences mantle thermal structure and the evolution of the core and geodynamo. In more recent results we have been additionally including primordial material. We find that melting-induced differentiation has several first-order effects on the dynamics, including (i) making plate tectonics easier (through stresses associated with lateral variations in crustal thickness) and (ii) reducing heat flux through the CMB (due to the build-up of dense material above the CMB); also (iii) tectonic mode (continuous plate tectonics, episodic lid or stagnant lid) also makes a first-order difference to mantle structure and dynamics. This emphasises

  13. Integrated light-guide plates that can control the illumination angle for liquid crystal display backlight system

    NASA Astrophysics Data System (ADS)

    Feng, Di; Yang, Xingpeng; Jin, Guofan; Yan, Yingbai; Fan, Shoushan

    2006-01-01

    Liquid crystal displays (LCDs) with edge-lit backlight systems offer several advantages, such as low energy consuming, low weight, and high uniformity of intensity, over traditional cathode-ray tube displays, and make them ideal for many applications including monitors in notebook personal computers, screens for TV, and many portable information terminals, such as mobile phones, personal digital assistants, etc. To satisfy market requirements for mobile and personal display panels, it is more and more necessary to modify the backlight system and make it thinner, lighter, and brighter all at once. In this paper, we have proposed a new integrated LGP based on periodic and aperiodic microprism structures by using polymethyl methacrylate material, which can be designed to control the illumination angle, and to get high uniformity of intensity. So the backlight system will be simplified to use only light sources and one LGP without using other optical sheets, such as reflection sheet, diffusion sheet and prism sheets. By using optimizing program and ray tracing method, the designed LGPs can achieve a uniformity of intensity better than 86%, and get a peak illumination angle from +400 to -200, without requiring other optical sheets. We have designed a backlight system with only one LED light source and one LGP, and other LGP design examples with different sizes (1.8 inches and 14.1 inches) and different light source (LED or CCFL), are performed also.

  14. Plating To Reinforce Welded Joints

    NASA Technical Reports Server (NTRS)

    Otousa, J. E.

    1982-01-01

    Electrodeposition used to strengthen welded joints gouged, nicked, or suffered other mechanical damage. Plating cell, typically of acrylic plastic such as poly (Methylmetacrylate), is assembled around part to be plated. Areas not to be plated are masked with plater's tape. Weld area is plated in standard nickel-plating process.

  15. Pyramidal approach to license plate segmentation

    NASA Astrophysics Data System (ADS)

    Postolache, Alexandru; Trecat, Jacques C.

    1996-07-01

    Car identification is a goal in traffic control, transport planning, travel time measurement, managing parking lot traffic and so on. Most car identification algorithms contain a standalone plate segmentation process followed by a plate contents reading. A pyramidal algorithm for license plate segmentation, looking for textured regions, has been developed on a PC based system running Unix. It can be used directly in applications not requiring real time. When input images are relatively small, real-time performance is in fact accomplished by the algorithm. When using large images, porting the algorithm to special digital signal processors can easily lead to preserving real-time performance. Experimental results, for stationary and moving cars in outdoor scenes, showed high accuracy and high scores in detecting the plate. The algorithm also deals with cases where many character strings are present in the image, and not only the one corresponding to the plate. This is done by the means of a constrained texture regions classification.

  16. Stability of simply supported and clamped elliptical plates

    NASA Astrophysics Data System (ADS)

    Rao, A. V.; Rao, B. N.; Prasad, K. L.

    1992-12-01

    Formulas are developed for estimating the elastic stability of an elliptical plate under compressive forces uniformly distributed around the edge of the plate. Then, a Cartesian coordinate system is used to perform the stability analysis of simply supported and clamped elliptical plates by following the Rayleigh-Ritz technique with a three-term deflection function.

  17. The Effects of Ni-Plating and Prolonged High Temperature Oxidation at 1423 K (1150 °C) on a CMSX-10 Single-Crystal Ni-Based Super-Alloy and Coating System

    NASA Astrophysics Data System (ADS)

    Clancy, Marie; Pomeroy, Michael J.

    2013-07-01

    A hypothesis was investigated, to assess if Ni-plating a 3rd-generation single-crystal alloy could favorably alter the diffusion profile of critical elements such that brittle, deleterious topologically close-packed (TCP) phases did not form or at least the extent to which they did was reduced. In conjunction with delaying the onset of these phases, it was hoped that more favorable alternatives could be promoted, such as martensite (β'). This study showed that Ni-plating did have some positive effects on the super-alloy/coating system. While the coating produced on the Ni-plated alloy was thinner, it retained a higher Al content than its unplated counterpart when subjected to oxidation. The retention of Al within the coating delayed the phase evolution of the coating from a β or β + β' to a γ'-dominant coating as the Ni-plated system had a greater driving force for Ni and Al diffusion, which helped to establish the Ni-rich diffusion barrier that entrapped Al in the coating. Unfortunately, Ni-plating does not sufficiently alter the diffusion profiles within the alloy to prevent precipitation of the TCP phases. Four pairs of the CMSX-10 alloy were used for this study. While they were all aluminized, only half of them, one in each pair, were Ni plated prior to aluminizing. Three of the four pairs were then oxidized at 1423 K (1150 °C), while the first pair was kept as a standard. X-ray diffraction, scanning electron microscopy, and energy dispersive X-ray spectroscopy were used to characterize each alloy-coating system in an effort to better understand their performance under high temperature oxidation.

  18. Vacuum fusion bonding of glass plates

    DOEpatents

    Swierkowski, Steve P.; Davidson, James C.; Balch, Joseph W.

    2000-01-01

    An improved apparatus and method for vacuum fusion bonding of large, patterned glass plates. One or both glass plates are patterned with etched features such as microstructure capillaries and a vacuum pumpout moat, with one plate having at least one hole therethrough for communication with a vacuum pumpout fixture. High accuracy alignment of the plates is accomplished by a temporary clamping fixture until the start of the fusion bonding heat cycle. A complete, void-free fusion bond of seamless, full-strength quality is obtained through the plates; because the glass is heated well into its softening point and because of a large, distributed force that is developed that presses the two plates together from the difference in pressure between the furnace ambient (high pressure) and the channeling and microstructures in the plates (low pressure) due to the vacuum drawn. The apparatus and method may be used to fabricate microcapillary arrays for chemical electrophoresis; for example, any apparatus using a network of microfluidic channels embedded between plates of glass or similar moderate melting point substrates with a gradual softening point curve, or for assembly of glass-based substrates onto larger substrates, such as in flat panel display systems.

  19. Vacuum fusion bonding of glass plates

    DOEpatents

    Swierkowski, Steve P.; Davidson, James C.; Balch, Joseph W.

    2001-01-01

    An improved apparatus and method for vacuum fusion bonding of large, patterned glass plates. One or both glass plates are patterned with etched features such as microstructure capillaries and a vacuum pumpout moat, with one plate having at least one hole therethrough for communication with a vacuum pumpout fixture. High accuracy alignment of the plates is accomplished by a temporary clamping fixture until the start of the fusion bonding heat cycle. A complete, void-free fusion bond of seamless, full-strength quality is obtained through the plates; because the glass is heated well into its softening point and because of a large, distributed force that is developed that presses the two plates together from the difference in pressure between the furnace ambient (high pressure) and the channeling and microstructures in the plates (low pressure) due to the vacuum drawn. The apparatus and method may be used to fabricate microcapillary arrays for chemical electrophoresis; for example, any apparatus using a network of microfluidic channels embedded between plates of glass or similar moderate melting point substrates with a gradual softening point curve, or for assembly of glass-based substrates onto larger substrates, such as in flat panel display systems.

  20. Analysis of hydraulic instability of ANS involute fuel plates

    SciTech Connect

    Sartory, W.K.

    1991-11-01

    Curved shell equations for the involute Advanced Neutron Source (ANS) fuel plates are coupled to two-dimensional hydraulic channel flow equations that include fluid friction. A complete set of fluid and plate boundary conditions is applied at the entrance and exit and along the sides of the plate and the channel. The coupled system is linearized and solved to assess the hydraulic instability of the plates.

  1. Simultaneous runs of the Bayer VERSANT HIV-1 version 3.0 and HCV bDNA version 3.0 quantitative assays on the system 340 platform provide reliable quantitation and improved work flow.

    PubMed

    Elbeik, Tarek; Markowitz, Norman; Nassos, Patricia; Kumar, Uday; Beringer, Scott; Haller, Barbara; Ng, Valerie

    2004-07-01

    Branched DNA (bDNA) assays to quantify human immunodeficiency virus type 1 (HIV-1) and hepatitis C virus (HCV) consist of three distinct steps, including sample processing, hybridization, and detection, and utilize the System 340 platform for plate incubation and washing. Sample processing differs: HIV-1 from 1 ml of plasma is concentrated by high-speed centrifugation, whereas HCV plasma or serum samples are used without concentration. The first step of hybridization involves viral lysis at 63 degrees C: HIV-1 is performed in a heat block, whereas HCV is performed in System 340. The remaining hybridization and detection steps are similar for HIV-1 and HCV and executed on System 340. In the present study, the HIV-1 bDNA assay was adapted for viral lysis in the System 340 platform. The adaptation, test method 2, includes a 20-s vortex of concentrated viral pellet and lysis working solution, transfer of viral lysate to the 96-well capture plate, and transfer to System 340 programmed for HCV assay specifications. With test method 2, specificity and quantification were within assay specifications. HCV bDNA methodology remains unchanged. Hence, an HIV-1 and an HCV bDNA can be run simultaneously on System 340. With simultaneous testing, laboratories can run full plates, as well as combinations of full and partial plates. Also, simultaneous HIV-1 and HCV bDNA permits labor consolidation and improved workflow while maintaining multitasking and rapid patient result turnaround. PMID:15243070

  2. Earthquakes and plate tectonics.

    USGS Publications Warehouse

    Spall, H.

    1982-01-01

    Earthquakes occur at the following three kinds of plate boundary: ocean ridges where the plates are pulled apart, margins where the plates scrape past one another, and margins where one plate is thrust under the other. Thus, we can predict the general regions on the earth's surface where we can expect large earthquakes in the future. We know that each year about 140 earthquakes of magnitude 6 or greater will occur within this area which is 10% of the earth's surface. But on a worldwide basis we cannot say with much accuracy when these events will occur. The reason is that the processes in plate tectonics have been going on for millions of years. Averaged over this interval, plate motions amount to several mm per year. But at any instant in geologic time, for example the year 1982, we do not know, exactly where we are in the worldwide cycle of strain build-up and strain release. Only by monitoring the stress and strain in small areas, for instance, the San Andreas fault, in great detail can we hope to predict when renewed activity in that part of the plate tectonics arena is likely to take place. -from Author

  3. Lohse's historic plate archive

    NASA Astrophysics Data System (ADS)

    Tsvetkov, M.; Tsvetkova, K.; Richter, G.; Scholz, G.; Böhm, P.

    The description and the analysis of Oswald Lohse's astrophotographic plates, collected at the Astrophysical Observatory Potsdam in the period 1879 - 1889, are presented. 67 plates of the archive, taken with the greatest instrument of the observatory at that time - the refractor (D = 0.30 m, F = 5.40 m, scale = 38''/mm) and with the second heliographic objective (D = 0.13 m, F = 1.36 m, scale = 152''/mm) - - survived two world wars in relative good condition. The plate emulsions are from different manufacturers in the beginning of astrophotography (Gädicke, Schleussner, Beernaert, etc.). The sizes of the plates are usually 9x12 cm2, which corresponds to fields of 1.2deg and 5deg respectively for each instrument mentioned above. The average limiting magnitude is 13.0(pg). Besides of the plates received for technical experiments (work on photographic processes, testing of new instruments and methods of observations), the scientific observations follow programs for studies of planet surfaces, bright stars, some double stars, stellar clusters and nebulous objects. Lohse's archive is included into the Wide Field Plate Database (http://www.skyarchive.org) as the oldest systematic one, covering the fields of Orion (M42/43), Pleiades, h & chi Persei, M37, M3, M11, M13, M92, M31, etc. With the PDS 2020 GM+ microdensitometer of Münster University 10 archive plates were digitized.

  4. Computational valve plate design

    NASA Astrophysics Data System (ADS)

    Kalbfleisch, Paul

    Axial piston machines are widely used in many industries for their designs compactness, flexibility in power transfer, variable flow rate, and high efficiencies as compared to their manufacturing costs. One important component of all axial piston machines that is a very influential on the performance of the unit is the valve plate. The aim of this research is to develop a design methodology that is general enough to design all types of valve plates and the simple enough not to require advanced technical knowledge from the user. A new style of valve plate designs has been developed that comprehensively considers all previous design techniques and does not require significant changes to the manufacturing processes of valve plates. The design methodology utilizes a previously developed accurate computer model of the physical phenomenon. This allows the precise optimization of the valve plate design through the use of simulations rather than expensive trial and error processes. The design of the valve plate is clarified into the form of an optimization problem. This formulation into an optimization problem has motivated the selection of an optimization algorithm that satisfies the requirements of the design. The proposed design methodology was successfully tested in a case study in the shown to be very successful in improving required performance of the valve plate design.

  5. Plate removal following orthognathic surgery.

    PubMed

    Little, Mhairi; Langford, Richard Julian; Bhanji, Adam; Farr, David

    2015-11-01

    The objectives of this study are to determine the removal rates of orthognathic plates used during orthognathic surgery at James Cook University Hospital and describe the reasons for plate removal. 202 consecutive orthognathic cases were identified between July 2004 and July 2012. Demographics and procedure details were collected for these patients. Patients from this group who returned to theatre for plate removal between July 2004 and November 2012 were identified and their notes were analysed for data including reason for plate removal, age, smoking status, sex and time to plate removal. 3.2% of plates were removed with proportionally more plates removed from the mandible than the maxilla. 10.4% of patients required removal of one or more plate. Most plates were removed within the first post-operative year. The commonest reasons for plate removal were plate exposure and infection. The plate removal rates in our study are comparable to those seen in the literature.

  6. Three-thrust fault system at the plate suture of arc-continent collision in the southernmost Longitudinal Valley, eastern Taiwan

    NASA Astrophysics Data System (ADS)

    Lee, J.; Chen, H.; Hsu, Y.; Yu, S.

    2013-12-01

    Active faults developed into a rather complex three-thrust fault system at the southern end of the narrow Longitudinal Valley in eastern Taiwan, a present-day on-land plate suture between the Philippine Sea plate and Eurasia. Based on more than ten years long geodetic data (including GPS and levelling), field geological investigation, seismological data, and regional tomography, this paper aims at elucidating the architecture of this three-thrust system and the associated surface deformation, as well as providing insights on fault kinematics, slip behaviors and implications of regional tectonics. Combining the results of interseismic (secular) horizontal and vertical velocities, we are able to map the surface traces of the three active faults in the Taitung area. The west-verging Longitudinal Valley Fault (LVF), along which the Coastal Range of the northern Luzon arc is thrusting over the Central Range of the Chinese continental margin, braches into two active strands bounding both sides of an uplifted, folded Quaternary fluvial deposits (Peinanshan massif) within the valley: the Lichi fault to the east and the Luyeh fault to the west. Both faults are creeping, to some extent, in the shallow surface level. However, while the Luyeh fault shows nearly pure thrust type, the Lichi fault reveals transpression regime in the north and transtension in the south end of the LVF in the Taitung plain. The results suggest that the deformation in the southern end of the Longitudinal Valley corresponds to a transition zone from present arc-collision to pre-collision zone in the offshore SE Taiwan. Concerning the Central Range, the third major fault in the area, the secular velocities indicate that the fault is mostly locked during the interseismic period and the accumulated strain would be able to produce a moderate earthquake, such as the example of the 2006 M6.1 Peinan earthquake, expressed by an oblique thrust (verging toward east) with significant left-lateral strike slip

  7. A liquid phase based C. elegans behavioral analysis system identifies motor activity loss in a nematode Parkinson's disease model.

    PubMed

    Zheng, Maohua; Gorelenkova, Olga; Yang, Jiong; Feng, Zhaoyang

    2012-03-15

    Motor activity of Caenorhabditis elegans is widely used to study the mechanisms ranging from basic neuronal functions to human neurodegenerative diseases. It may also serve as a paradigm to screen for potential therapeutic reagents treating these diseases. Here, we developed an automated, 96-well plate and liquid phase based system that quantifies nematode motor activity in real time. Using this system, we identified an adult-onset, ageing-associated motor activity loss in a transgenic nematode line expressing human pathogenic G2019S mutant LRRK2 (leucine-rich repeat kinase 2), the leading genetic cause of Parkinson's disease characterized by dopaminergic neurodegeneration associated motor deficient mainly in elder citizens. Thus, our system may be used as a platform to screen for potential therapeutic drugs treating Parkinson's disease. It can also be used to monitor motor activity of nematodes in liquid phase at similar scenario.

  8. Reduction of astrometric plates

    NASA Technical Reports Server (NTRS)

    Stock, J.

    1984-01-01

    A rapid and accurate method for the reduction of comet or asteroid plates is described. Projection equations, scale length correction, rotation of coordinates, linearization, the search for additional reference stars, and the final solution are examined.

  9. Violin plate modes.

    PubMed

    Gough, Colin

    2015-01-01

    As the first step toward developing a generic model for the acoustically radiating vibrational modes of the violin and related instruments, the modes of both freely supported and edge-constrained top and back plates have been investigated as functions of shape, arching height, elastic anisotropy, the f-holes and associated island area, thickness graduations, and the additional boundary constraints of the ribs, soundpost, and bass-bar present in the assembled instrument. Comsol shell structure finite element software has been used as a quasi-experimental tool, with physical and geometric properties varied smoothly, often over several orders of magnitude, allowing the development of the plate modes to be followed continuously from those of an initially square plate to those of doubly-arched, guitar-shaped, orthotropic plates and their dependence on all the above factors. PMID:25618046

  10. Violin plate modes.

    PubMed

    Gough, Colin

    2015-01-01

    As the first step toward developing a generic model for the acoustically radiating vibrational modes of the violin and related instruments, the modes of both freely supported and edge-constrained top and back plates have been investigated as functions of shape, arching height, elastic anisotropy, the f-holes and associated island area, thickness graduations, and the additional boundary constraints of the ribs, soundpost, and bass-bar present in the assembled instrument. Comsol shell structure finite element software has been used as a quasi-experimental tool, with physical and geometric properties varied smoothly, often over several orders of magnitude, allowing the development of the plate modes to be followed continuously from those of an initially square plate to those of doubly-arched, guitar-shaped, orthotropic plates and their dependence on all the above factors.

  11. Flat plate solar oven

    SciTech Connect

    Parikh, M.

    1981-01-01

    The construction of an Indian Rs. 186 (US $20.33) flat-plate solar oven is described. Detailed drawings are provided and relevant information on cooking times and temperature for different foods is given.

  12. Tectonic Plate Movement.

    ERIC Educational Resources Information Center

    Landalf, Helen

    1998-01-01

    Presents an activity that employs movement to enable students to understand concepts related to plate tectonics. Argues that movement brings topics to life in a concrete way and helps children retain knowledge. (DDR)

  13. Plate tectonics: Metamorphic myth

    NASA Astrophysics Data System (ADS)

    Korenaga, Jun

    2016-01-01

    Clear evidence for subduction-induced metamorphism, and thus the operation of plate tectonics on the ancient Earth has been lacking. Theoretical calculations indicate that we may have been looking for something that cannot exist.

  14. Quantitative turbidity assay for lipolytic enzymes in microtiter plates.

    PubMed

    Barig, Susann; Schiemann, Manja; Mirsky, Vladimir M; Stahmann, K Peter

    2013-10-01

    A clearing assay for lipolytic enzymes has been realized in 96-well microtiter plates. A thin layer containing emulsified tributyrin as turbidity-generating substrate was placed on a thicker supporting aqueous layer. Both layers were stabilized by a gel-forming agent. Enzyme addition leads to clearing of the emulsion detected with a standard microtiter plate reader as a decrease of extinction. Dependencies of the signal kinetics on the substrate and enzyme concentrations were studied. For 0.5-1% tributyrin content the reaction rate is not substrate-limited. An initial slope of the signal kinetics is proportional to the lipase activity. A detailed characterization of the assay was performed. Lipolysis of tributyrin was confirmed by glycerol detection. Various gel-forming agents were compared and diffusion conditions in these gels were analyzed. Agar and agarose were found to be the most suitable gel-forming agents, which do not affect enzyme diffusion whereas polyacrylamide gels block lipase diffusion and therefore are not suitable for the assay. The optimized assay prepared from 1% tributyrin emulsion in 2% agar gel was tested with six microbial lipases and porcine pancreatic lipase. The detection limit is 20-60 ng/well which is equivalent to 30 μU/well for T. lanuginosus lipase.

  15. New Method for Accurate Calibration of Micro-Channel Plate based Detection Systems and its use in the Fast Plasma Investigation of NASA's Magnetospheric MultiScale Mission

    NASA Astrophysics Data System (ADS)

    Gliese, U.; Avanov, L. A.; Barrie, A.; Kujawski, J. T.; Mariano, A. J.; Tucker, C. J.; Chornay, D. J.; Cao, N. T.; Zeuch, M.; Pollock, C. J.; Jacques, A. D.

    2013-12-01

    The Fast Plasma Investigation (FPI) of the NASA Magnetospheric MultiScale (MMS) mission employs 16 Dual Electron Spectrometers (DESs) and 16 Dual Ion Spectrometers (DISs) with 4 of each type on each of 4 spacecraft to enable fast (30ms for electrons; 150ms for ions) and spatially differentiated measurements of full the 3D particle velocity distributions. This approach presents a new and challenging aspect to the calibration and operation of these instruments on ground and in flight. The response uniformity and reliability of their calibration and the approach to handling any temporal evolution of these calibrated characteristics all assume enhanced importance in this application, where we attempt to understand the meaning of particle distributions within the ion and electron diffusion regions. Traditionally, the micro-channel plate (MCP) based detection systems for electrostatic particle spectrometers have been calibrated by setting a fixed detection threshold and, subsequently, measuring a detection system count rate plateau curve to determine the MCP voltage that ensures the count rate has reached a constant value independent of further variation in the MCP voltage. This is achieved when most of the MCP pulse height distribution (PHD) is located at higher values (larger pulses) than the detection amplifier threshold. This method is adequate in single-channel detection systems and in multi-channel detection systems with very low crosstalk between channels. However, in dense multi-channel systems, it can be inadequate. Furthermore, it fails to fully and individually characterize each of the fundamental parameters of the detection system. We present a new detection system calibration method that enables accurate and repeatable measurement and calibration of MCP gain, MCP efficiency, signal loss due to variation in gain and efficiency, crosstalk from effects both above and below the MCP, noise margin, and stability margin in one single measurement. The fundamental

  16. A hypothesis for Proterozoic-Phanerozoic supercontinent cyclicity, with implications for mantle convection, plate tectonics and Earth system evolution

    NASA Astrophysics Data System (ADS)

    Grenholm, Mikael; Scherstén, Anders

    2015-11-01

    relation to mantle convection and Earth system evolution.

  17. Positive battery plate

    NASA Technical Reports Server (NTRS)

    Rowlette, John R. (Inventor)

    1985-01-01

    The power characteristics of a lead acid battery are improved by incorporating a dispersion of 1 to 10% by weight of a thermodynamically stable conductivity additive, such as conductive tin oxide coated glass fibers (34) of filamentary glass wool (42) in the positive active layer (32) carried on the grid (30) of the positive plate (16). Positive plate potential must be kept high enough to prevent reduction of the tin oxide to tin by utilizing an oversized, precharged positive paste.

  18. Fractal multifiber microchannel plates

    NASA Technical Reports Server (NTRS)

    Cook, Lee M.; Feller, W. B.; Kenter, Almus T.; Chappell, Jon H.

    1992-01-01

    The construction and performance of microchannel plates (MCPs) made using fractal tiling mehtods are reviewed. MCPs with 40 mm active areas having near-perfect channel ordering were produced. These plates demonstrated electrical performance characteristics equivalent to conventionally constructed MCPs. These apparently are the first MCPs which have a sufficiently high degree of order to permit single channel addressability. Potential applications for these devices and the prospects for further development are discussed.

  19. Strongly coupled stress waves in heterogeneous plates.

    NASA Technical Reports Server (NTRS)

    Wang, A. S. D.; Chou, P. C.; Rose, J. L.

    1972-01-01

    Consideration of coupled stress waves generated by an impulsive load applied at one end of a semiinfinite plate. For the field equations governing the one-dimensional coupled waves a hyperbolic system of equations is obtained in which a strong coupling in the second derivatives exists. The method of characteristics described by Chou and Mortimer (1967) is extended to cover the case of strong coupling, and a study is made of the transient stress waves in a semiinfinite plate subjected to an initial step input. Coupled discontinuity fronts are found to propagate at different velocities. The normal plate stress and the bending moment at different time regimes are illustrated by graphs.

  20. The Potsdam Plate Archive

    NASA Astrophysics Data System (ADS)

    Boehm, P.; Steinmetz, M.; Tsvetkov, M.; Tsvetkova, K.

    2006-08-01

    The Virtual Observatory (VO) project will provide a global network platform to support modern astronomical research with fast and easy access to distributed archives via a unified interface and data model. Our aim is to include the historical photographic plates of the Potsdam observatory into this database in the framework of GAVO, the German contribution to VO. This work is part of the DFG project 436 BUL. The Postdam collection of wide-field plates consists of 11 archives, obtained from 1879 to 1970 (see Catalogue of Wide-Field Plate Archives, version 5.0, March 2005, http://www.skyarchive.org/catalogue.html), with a total amount of about 10000 plates and films stored not only in Potsdam but also in Leiden and Sonneberg. Apart from the long timeline provided for the observed objects, the archives reflect the history and development of the Potsdam observatory and of astronomical photography as well. The first astronomical photographs represent a scientific treasure. They offer the possibility to follow the photometric behavior of astronomical objects for about 120 years. This information is unique, because no more reproducible. Our aim is to digitize the old plates as long as their physical status does still allow it, and continue their systematic incorporation into the already existing Wide-Field Plate Database. These data can be used to search for any kind of long-term brightness variations like new flare stars or rapidly varying stars (Froehlich et al., 2002, A&A 391).

  1. Involvement of the German Research Center for GeoSciences (GFZ) in the EPOS Implementation Phase 2015-18 (European Plate Observing System)

    NASA Astrophysics Data System (ADS)

    Hoffmann, T. L.; Lauterjung, J.

    2015-12-01

    Under the Horizon 2020 Programme INFRADEV-3, the European Commission (EC) has awarded a prioritized grant for the establishment of the European Plate Observing System (EPOS) during a four-year Implementation Phase 2015-18. As laid in detail during the EPOS Preparatory Phase 2010-14, the EPOS cyberinfrastructure will be established as an ERIC (European Research Infrastructure Consortium) and it will encompass the implementation of both the EPOS Integrated Core Services (ICS) for solid Earth Science and a multitude of EPOS Thematic Core Services (TCS). As one of the 29 awardees of the EC grant, the German Research Center for Geosciences (GFZ) will play an important role in the implementation of EPOS and its Thematic and Integrated Core Services. The presented poster will give an overview of GFZ's involvement in the different Work Packages, including administrative tasks (WP3 Harmonization) as well as the technical implementation efforts (WP7 ICS Development, WP8 Seismology, WP11 Volcano Observations, WP12 Satellite Data, WP13 Geomagnetic Observations, WP14 Anthropogenic Hazards, WP15 Geological Information and Modelling, WP16 Multi-Scale Laboratories and WP17 Geo Energy Test Beds).

  2. Ethics issues in scientific data and service provision: evidence and challenges for the European Plate Observing System (EPOS)

    NASA Astrophysics Data System (ADS)

    Cocco, Massimo; Freda, Carmela; Haslinger, Florian; Consortium, Epos

    2016-04-01

    Addressing Ethics issues is nowadays a relevant challenge for any initiative, program or project dealing with scientific data and products provision, access to services for scientific purposes and communication with different stakeholders, including society. This is corroborated by the evidence that Ethics has very high priority in EU funded research. Indeed, all the activities carried out under Horizon 2020 must comply with ethical principles and national, Union and international legislation. This implies that "For all activities funded by the European Union, Ethics is an integral part of research from beginning to end, and ethical compliance is seen as pivotal to achieve real research excellence." Here, we present the experience of EPOS, a public pan-European research infrastructure. EPOS aims at integrating data, data products, services and software (DDSS) for solid Earth science generated and provided by monitoring networks, observing systems and facilities belonging to European countries. EPOS fosters the integrated use of multidisciplinary solid Earth data to improve the understanding of physical and chemical processes controlling earthquakes, volcanic eruptions, tsunamis as well as those driving tectonics and surface dynamics. The EPOS integration plan will make significant contributions to understanding and mitigating geo-hazards, yielding data for hazard assessment, data products for engaging different stakeholders, and services for training, education and communication to society. Numerous national research infrastructures engaged in EPOS are deployed for the monitoring of areas prone to geo-hazards and for the surveillance of the national territory including areas used for exploiting geo-resources. The EPOS community is therefore already trained to provide services to public (civil defence agencies, local and national authorities) and private (petroleum industry, mining industry, geothermal companies, aviation security) stakeholders. Our ability to

  3. A clamped rectangular plate containing a crack

    NASA Technical Reports Server (NTRS)

    Tang, R.; Erdogan, F.

    1985-01-01

    The general problem of a rectangular plate clamped along two parallel sides and containing a crack parallel to the clamps is considered. The problem is formulated in terms of a system of singular integral equations and the asymptotic behavior of the stress state near the corners is investigated. Numerical examples are considered for a clamped plate without a crack and with a centrally located crack, and the stress intensity factors and the stresses along the clamps are calculated.

  4. Electrochemical cell and separator plate thereof

    DOEpatents

    Baker, Bernard S.; Dharia, Dilip J.

    1979-01-01

    A fuel cell includes a separator plate having first and second flow channels extending therethrough contiguously with an electrode and respectively in flow communication with the cell electrolyte and in flow isolation with respect to such electrolyte. In fuel cell system arrangement, the diverse type channels are suplied in common with process gas for thermal control purposes. The separator plate is readily formed by corrugation of integral sheet material.

  5. Caribbean plate interactions

    SciTech Connect

    Ball, M. )

    1993-02-01

    Vector analysis of plate motions, derived from studies of Atlantic magnetic lineations and fracture zone trends, indicates the following relative movements between the Caribbean, North American, and South American Plates. (1) During Early Jurassic to Early Cretaceous, the North American Plate moved 1900 km westward and 900 km northward relative to the South American Plate. A broad zone including the Caribbean region, i.e., the zone between the North and South America Plates, was a site of left-lateral shear and north-south extension. (2) During Early Cretaceous to Late Cretaceous, the North American Mate moved an additional 1200 km westward relative to South America across this zone. (3) During Late Cretaceous to the end of the Eocene, the North American Plate moved 200 km westward and 400 km northward relative to the South American Plate. (4) From the end of the Eocene to near the end of the Miocene, North America converged on South America some 200 km and moved 100 km eastward relative to it. Through the Mesozoic and earliest Tertiary history of the Caribbean, the region was a shear zone within which left-lateral displacement exceeded 3000 km and north-south extension exceeded 1300 km. In regard to time, 80% of the history of the Caribbean region is one of north-south extension and left-lateral shear. In terms of space, 97% of the shear is left-lateral and the ratio of divergence versus convergence is 7 to 1. Thus, characterizing the Caribbean region, and the Atlantic to its east, as a zone of north-south extension and left-lateral shear, is a fair generalization.

  6. Improvements in Cold-Plate Fabrication

    NASA Technical Reports Server (NTRS)

    Zaffetti, Mark A.; Taddey, Edmund P.; Laurin, Michael B.; Chabebe, Natalia

    2012-01-01

    Five improvements are reported in cold-plate fabrication. This cold plate is part of a thermal control system designed to serve on space missions. The first improvement is the merging of the end sheets of the cold plate with the face sheets of the structural honeycomb panel. The cold plate, which can be a brazed assembly, uses the honeycomb face sheet as its end sheet. Thus, when the honeycomb panel is fabricated, the face sheet that is used is already part of the cold plate. In addition to reducing weight, costs, and steps, the main benefit of this invention is that it creates a more structurally sound assembly. The second improvement involves incorporation of the header into the closure bar to pass the fluid to a lower layer. Conventional designs have used a separate header, which increases the geometry of the system. The improvement reduces the geometry, thus allowing the cold plate to fit into smaller area. The third improvement eliminates the need of hose, tube, or manifold to supply the cooling fluid externally. The external arrangement can be easily damaged and is vulnerable to leakage. The new arrangement incorporates an internal fluid transfer tube. This allows the fluid to pass from one cold plate to the other without any exposed external features. The fourth improvement eliminates separate fabrication of cold plate(s) and structural members followed by a process of attaching them to each other. Here, the structural member is made of material that can be brazed just as that of the cold plate. Now the structural member and the cold plate can be brazed at the same time, creating a monolithic unit, and thus a more structurally sound assembly. Finally, the fifth improvement is the elimination of an additional welding step that can damage the braze joints. A tube section, which is usually welded on after the braze process, is replaced with a more structurally sound configuration that can be brazed at the same time as the rest of the cold plate.

  7. Study on plate silencer with general boundary conditions

    NASA Astrophysics Data System (ADS)

    Liu, Gongmin; Zhao, Xiaochen; Zhang, Wenping; Li, Shuaijun

    2014-09-01

    A plate silencer consists of an expansion chamber with two side-branch rigid cavities covered by plates. Previous studies showed that, in a duct, the introduction of simply supported or clamped plates into an air conveying system could achieve broadband quieting from low to medium frequencies. In this study, analytical formulation is extended to the plate silencer with general boundary conditions. A set of static beam functions, which are a combination of sine series and third-order polynomial, is employed as the trial functions of the plate vibration velocity. Greens function and Kirchhoff-Helmholtz integral are used to solve the sound radiation in the duct and the cavity, and then the vibration velocity of the plate is obtained. Having obtained the vibration velocity, the pressure perturbations induced by the plate oscillation and the transmission loss are found. Optimization is carried out in order to obtain the widest stopband. The transmission loss calculated by the analytical method agrees closely with the result of the finite element method simulation. Further studies with regard to the plate under several different classical boundary conditions based on the validated model show that a clamped-free plate silencer has the worst stopband. Attempts to release the boundary restriction of the plate are also made to study its effect on sound reflection. Results show that a softer end for a clamped-clamped plate silencer helps increase the optimal bandwidth, while the same treatment for simply supported plate silencer will result in performance degradation.

  8. Automated screening method for determining optimum preservative systems for personal and home care products.

    PubMed

    Lenczewski, M E; Kananen, L L

    1998-01-01

    A procedure was designed to determine the minimum preservative level (MPL) for personal and home care products. A highly preserved sample and an unpreserved sample were combined at different concentrations within a 96-well microtiter plate by using an autodilutor. A unique tip design made it possible to accurately deliver viscous test materials that cannot be dispensed using vacuum- or fluid-filled systems. After inoculation, the sample was evaluated at a specified time interval for the presence of surviving bacteria, yeast, and mold. The lowest concentration of preservative with no microbial growth is the recommended level of preservative for the product. Because sample turbidity may interfere with determination of the endpoint, a colorimetric endpoint was used to indicate growth of microorganisms and to differentiate product from growth. The predicted levels were tested with a modified Cosmetic, Toiletry, and Fragrance Association method. The method successfully predicted effective preservative levels in many personal and home care products with a broad range of viscosities.

  9. Bipolar battery plate

    NASA Technical Reports Server (NTRS)

    Rowlette, John J. (Inventor)

    1987-01-01

    A liquid-impermeable plate (10) having through-plate conductivity with essentially zero resistance comprises an insulator sheet (12) having a series of spaced perforations (14) each of which contains a metal element (16) sealingly received into the perforation (14). A low-cost plate can readily be manufactured by punching a thermoplastic sheet (40) such as polypropylene with a punching tool (52), filling the apertures with led spheres (63) having a diameter smaller than the holes (50) but larger than the thickness of the sheet, sweeping excess spheres (62) off the sheet with a doctor blade (60) and then pressing a heated platen (74) onto the sheet to swage the spheres into a cylindrical shape and melt the surrounding resin to form a liquid-impermeable collar (4) sealing the metal into the sheet.

  10. [Theoretical analysis and numerical simulation of effect of steel plate positions on steel plate rigidity in internal fixation of bone surgery].

    PubMed

    Chen, Bingzhi; Gu, Yuanxian; Lü, Decheng; Lü, Xuemin

    2003-09-01

    In this study we calculate theoretically and use FEM to simulate the effect of plate position relative to bending direction on the overall bending stiffness of the composite system plate-bone. The results show that for different bending directions the effect of the modulus of elasticity of the plate is negligible. Changing the position of a plate will often alter the stress obviously. During the operation, the steel plate should be assigned onto the tension side of the bone. PMID:14565005

  11. Optimal stabilization of indefinite plate buckling problems

    NASA Astrophysics Data System (ADS)

    Chase, J. Geoffrey; Bhashyam, Srinivas

    2001-08-01

    Indefinite plate buckling problems arise when the applied load case results in buckling loads which are not all of the same sign. Examples include the important cases of shear buckling and general combinations of tensile and compressive in-plane edge loads. Optimal controllers which actively stabilize these general, indefinite plate buckling problems, by transforming them into a system of definite plate buckling problems, are presented. Important features of this approach include the ability to select the designed closed loop critical buckling load, and to pre-determine what load cases a given controller will stabilize when the exact load combination varies or is unknown. This last result enables the control designer to know exactly, by design, what load combinations will be stabilized. A numerical example is presented where the controllers developed are employed to stabilize multiple, definite and indefinite buckling modes for laminated composite plates similar to aircraft wing skins.

  12. Plate-mantle coupling from post-Pangea plate kinematics

    NASA Astrophysics Data System (ADS)

    Zahirovic, Sabin; Dietmar Müller, R.; Seton, Maria; Flament, Nicolas

    2015-04-01

    Convection in the Earth's mantle that involves plates at the surfaces gives rise to plate velocities that vary through time and depend on the balance of plate boundary forces, with the present-day providing a snapshot of this ongoing process. However, present-day plate velocities do not capture plate behaviour over geologically representative timeframes and thus cannot be used to evaluate factors limiting plate velocities. Previous studies investigated the effects of continental keels on plate speeds by either using the present-day snapshot or a limited number of reconstructed plate configurations, often leading to conflicting results. For example, an early assumption was that continental keels (especially cratons) were unlikely to impede fast plate motions because India's velocity approached ~20 cm/yr in the Eocene prior to the collision with Eurasia. We employ a modern plate reconstruction approach with evolving global topological plate boundaries for the post-Pangea timeframe (since 200 Ma) to evaluate factors controlling plate velocities. Plate boundary configurations and plate velocities are extracted from the open-source and cross-platform plate reconstruction package GPlates (www.gplates.org) at 1 Myr intervals. For each plate, at each timestep, the area of continental and cratonic lithosphere is calculated to evaluate the effect on plate velocities. Our results support that oceanic plates tend to be 2-3 times faster than plates with large portion of continental plate area, consistent with predictions of numerical models of mantle convection. The fastest plates (~8.5 cm/yr RMS) are dominated by oceanic plate area and high subducting portion of plate perimeter, while the slowest plates (~2.6-2.8 cm/yr RMS) are dominated by continental plate area and bounded by transforms and mid-oceanic ridge segments. Importantly, increasing cratonic fractions (both Proterozoic and Archean lithosphere) significantly impede plate velocities, suggesting that deep continental

  13. Optimization of a closed-loop gas system for the operation of Resistive Plate Chambers at the Large Hadron Collider experiments

    NASA Astrophysics Data System (ADS)

    Capeans, M.; Glushkov, I.; Guida, R.; Hahn, F.; Haider, S.

    2012-01-01

    Resistive Plate Chambers (RPCs), thanks to their fast time resolution (˜1 ns), suitable space resolution (˜1 cm) and low production cost (˜50 €/m2), are widely employed for the muon trigger systems at the Large Hadron Collider (LHC). Their large detector volume (they cover a surface of about 4000 m2 equivalent to 16 m3 of gas volume both in ATLAS and CMS) and the use of a relatively expensive Freon-based gas mixture make a closed-loop gas circulation unavoidable. It has been observed that the return gas of RPCs operated in conditions similar to the difficult experimental background foreseen at LHC contains a large amount of impurities potentially dangerous for long-term operation. Several gas-cleaning agents are currently in use in order to avoid accumulation of impurities in the closed-loop circuits. We present the results of a systematic study characterizing each of these cleaning agents. During the test, several RPCs were operated at the CERN Gamma Irradiation Facility (GIF) in a high radiation environment in order to observe the production of typical impurities: mainly fluoride ions, molecules of the Freon group and hydrocarbons. The polluted return gas was sent to several cartridges, each containing a different cleaning agent. The effectiveness of each material was studied using gas chromatography and mass-spectrometry techniques. Results of this test have revealed an optimized configuration of filters that is now under long-term validation.Gas optimization studies are complemented with a finite element simulation of gas flow distribution in the RPCs, aiming at its eventual optimization in terms of distribution and flow rate.

  14. NICKEL PLATING PROCESS

    DOEpatents

    Hoover, T.B.; Zava, T.E.

    1959-05-12

    A simplified process is presented for plating nickel by the vapor decomposition of nickel carbonyl. In a preferred form of the invention a solid surface is nickel plated by subjecting the surface to contact with a mixture containing by volume approximately 20% nickel carbonyl vapor, 2% hydrogen sulfide and .l% water vapor or 1% oxygen and the remainder carbon dioxide at room temperature until the desired thickness of nickel is obtained. The advantage of this composition over others is that the normally explosive nickel carbonyl is greatly stabilized.

  15. Reduced Plating Ignitron

    NASA Technical Reports Server (NTRS)

    Polzin, Kurt A (Inventor); Pearson, J Boise (Inventor)

    2014-01-01

    An ignitron apparatus has an airtight tubular housing having a first sealed end and a second sealed end. An anode is connected at the first sealed end, projecting into the housing, and a recess at the second sealed and forms a well which contains a quantity of liquid gallium or gallium alloy making up the cathode. An ignitor projects through the liquid metal and into the housing. The inner surface of the housing includes at least one plating-reduction structure to prevent electrical shorting of the apparatus caused by plating of the liquid metal.

  16. Modeling the hydrodynamics of Phloem sieve plates.

    PubMed

    Jensen, Kaare Hartvig; Mullendore, Daniel Leroy; Holbrook, Noel Michele; Bohr, Tomas; Knoblauch, Michael; Bruus, Henrik

    2012-01-01

    Sieve plates have an enormous impact on the efficiency of the phloem vascular system of plants, responsible for the distribution of photosynthetic products. These thin plates, which separate neighboring phloem cells, are perforated by a large number of tiny sieve pores and are believed to play a crucial role in protecting the phloem sap from intruding animals by blocking flow when the phloem cell is damaged. The resistance to the flow of viscous sap in the phloem vascular system is strongly affected by the presence of the sieve plates, but the hydrodynamics of the flow through them remains poorly understood. We propose a theoretical model for quantifying the effect of sieve plates on the phloem in the plant, thus unifying and improving previous work in the field. Numerical simulations of the flow in real and idealized phloem channels verify our model, and anatomical data from 19 plant species are investigated. We find that the sieve plate resistance is correlated to the cell lumen resistance, and that the sieve plate and the lumen contribute almost equally to the total hydraulic resistance of the phloem translocation pathway.

  17. A comparison of mantle convection models featuring plates

    NASA Astrophysics Data System (ADS)

    Stein, C.; Lowman, J. P.; Hansen, U.

    2014-06-01

    plates are an integral part of the Earth's mantle and thus play an important role in its dynamics and evolution. To allow plate behavior to arise naturally in numerical mantle convection models, self-consistent plate generation methods apply a fully rheological approach (featuring a temperature-, pressure- and stress-dependent viscosity). However, due to the extreme local viscosity changes that the self-generation of model plates entails, their computational requirements are demanding. Alternative plate modeling methods specify the existence of plates explicitly but can also obtain dynamically determined velocities (e.g., by employing a force-balance method). Here we present modifications to a force-balance model by utilizing a rheology-dependent viscosity profile. Accordingly, plate viscosity and plate thickness are no longer prescribed by the modeler but now follow as a dynamic consequence of the temperature and stress dependence of the viscosity and the model's evolution. We describe the new method and present benchmark results for a rheologically self-consistent mantle convection model and the modified force-balance plate model. Our results show that both plate modeling methods lead to the same system behavior for a wide range of system parameters making the new method a powerful tool to also achieve plate-like surface motion naturally.

  18. Intermittent Plate Tectonics

    NASA Astrophysics Data System (ADS)

    Silver, P. G.; Behn, M. D.

    2006-12-01

    Intermittent Plate Tectonics A basic premise of Earth Science is that plate tectonics has been continuously operating since it began early in Earth's history. Yet, plate-tectonic theory itself, specifically the collisional phase of the Wilson Cycle, constitutes a process that is capable of stopping all plate motion. The plausibility of a plate-tectonic hiatus is most easily illustrated by considering the expected future of the present-day plate-tectonic configuration. Since the opening of the Atlantic at ~200 ma, the area of the Atlantic basin has been growing at the expense of the Pacific. If this trend continues, relative plate motion models predict that in ~350 my, the Pacific Ocean basin will effectively close leading to widespread continent-continent collisions. Since a continent-continent collision represents the termination of subduction locally, the accumulated effect of all collisions is to stop subduction globally. In this scenario, ridges would then stop spreading and young oceanic lithosphere would cool, reaching a steady-state thickness of 100 km in about 80 my, based on the properties of oceanic lithosphere today. This would constitute the stoppage of plate tectonics. The presumption that plate tectonics never stops in the face of continental collisions is equivalent to requiring that subduction flux is approximately constant through time, such that subduction initiation roughly balances subduction termination. Such a balance then raises several questions about the subduction initiation process. When and how does subduction initiate? Is there a detectible relationship between subduction cessation and subduction initiation? We can gain some guidance into these questions by examining the plate motion history over the last 200 my. Subduction initiation has occurred over the last 80 my in three intra- oceanic subduction zones: Aleutians, Marianas-Izu-Bonin and Tonga-Kermadec in the Pacific basin. In these cases, however, subduction initiation would not

  19. Ponderomotive phase plate for transmission electron microscopes

    DOEpatents

    Reed, Bryan W.

    2012-07-10

    A ponderomotive phase plate system and method for controllably producing highly tunable phase contrast transfer functions in a transmission electron microscope (TEM) for high resolution and biological phase contrast imaging. The system and method includes a laser source and a beam transport system to produce a focused laser crossover as a phase plate, so that a ponderomotive potential of the focused laser crossover produces a scattering-angle-dependent phase shift in the electrons of the post-sample electron beam corresponding to a desired phase contrast transfer function.

  20. Robot Arm with Tendon Connector Plate and Linear Actuator

    NASA Technical Reports Server (NTRS)

    Ihrke, Chris A. (Inventor); Diftler, Myron A. (Inventor); Bridgwater, Lyndon (Inventor); Nguyen, Vienny (Inventor); Millerman, Alexander (Inventor)

    2014-01-01

    A robotic system includes a tendon-driven end effector, a linear actuator, a flexible tendon, and a plate assembly. The linear actuator assembly has a servo motor and a drive mechanism, the latter of which translates linearly with respect to a drive axis of the servo motor in response to output torque from the servo motor. The tendon connects to the end effector and drive mechanism. The plate assembly is disposed between the linear actuator assembly and the tendon-driven end effector and includes first and second plates. The first plate has a first side that defines a boss with a center opening. The second plate defines an accurate through-slot having tendon guide channels. The first plate defines a through passage for the tendon between the center opening and a second side of the first plate. A looped end of the flexible tendon is received within the tendon guide channels.

  1. Nuclear reactor alignment plate configuration

    DOEpatents

    Altman, David A; Forsyth, David R; Smith, Richard E; Singleton, Norman R

    2014-01-28

    An alignment plate that is attached to a core barrel of a pressurized water reactor and fits within slots within a top plate of a lower core shroud and upper core plate to maintain lateral alignment of the reactor internals. The alignment plate is connected to the core barrel through two vertically-spaced dowel pins that extend from the outside surface of the core barrel through a reinforcement pad and into corresponding holes in the alignment plate. Additionally, threaded fasteners are inserted around the perimeter of the reinforcement pad and into the alignment plate to further secure the alignment plate to the core barrel. A fillet weld also is deposited around the perimeter of the reinforcement pad. To accomodate thermal growth between the alignment plate and the core barrel, a gap is left above, below and at both sides of one of the dowel pins in the alignment plate holes through with the dowel pins pass.

  2. Unitary plate electrode

    NASA Technical Reports Server (NTRS)

    Rowlette, John J. (Inventor); Clough, Thomas J. (Inventor); Josefowicz, Jack Y. (Inventor); Sibert, John W. (Inventor)

    1985-01-01

    The unitary electrode (10) comprises a porous sheet (12) of fiberglass the strands (14) of which contain a coating (16) of conductive tin oxide. The lower portion of the sheet contains a layer (18) of resin and the upper layer (20) contains lead dioxide forming a positive active electrode on an electrolyte-impervious layer. The strands (14) form a continuous conduction path through both layers (16, 18). Tin oxide is prevented from reduction by coating the surface of the plate facing the negative electrode with a conductive, impervious layer resistant to reduction such as a thin film (130) of lead or graphite filled resin adhered to the plate with a layer (31) of conductive adhesive. The plate (10) can be formed by casting a molten resin from kettle (60) onto a sheet of glass wool (56) overlying a sheet of lead foil and then applying positive active paste from hopper (64) into the upper layer (68). The plate can also be formed by passing an assembly of a sheet ( 80) of resin, a sheet (86) of sintered glass and a sheet (90) of lead between the nip (92) of heated rollers (93, 95) and then filling lead oxide into the pores (116) of the upper layer (118).

  3. The Plate Tectonics Project

    ERIC Educational Resources Information Center

    Hein, Annamae J.

    2011-01-01

    The Plate Tectonics Project is a multiday, inquiry-based unit that facilitates students as self-motivated learners. Reliable Web sites are offered to assist with lessons, and a summative rubric is used to facilitate the holistic nature of the project. After each topic (parts of the Earth, continental drift, etc.) is covered, the students will…

  4. INL HIP Plate Fabrication

    SciTech Connect

    B. H. Park; C. R. Clark; J. F. Jue

    2010-02-01

    This document outlines the process used to bond monolithic fuel plates by Hot Isostatic Pressing (HIP). This method was developed at Idaho National Laboratory (INL) for the Reduced Enrichment for Research and Test Reactors (RERTR) program. These foils have been used in a number of irradiation experiments in support of the United States Global Threat Reduction Initiative (GTRI) program.

  5. Growth Plate Injuries

    MedlinePlus

    ... or crushed, the growth plate may close prematurely, forming a bony bridge or “bar.” The risk of ... this publication: James S. Panagis, M.D., M.P.H., NIAMS/NIH; R. Tracy Ballock, M.D., Case ...

  6. Simple defined autoinduction medium for high-level recombinant protein production using T7-based Escherichia coli expression systems.

    PubMed

    Li, Zhaopeng; Kessler, Wolfgang; van den Heuvel, Joop; Rinas, Ursula

    2011-08-01

    Protein production under the control of lac operon regulatory elements using autoinduction is based on diauxic growth of Escherichia coli on lactose after consumption of more preferred carbon substrates. A novel simple and cost-effective defined autoinduction medium using a mixture of glucose, glycerol, and lactose as carbon substrate and NH(4)(+) as sole nitrogen source without any supplementation of amino acids and vitamins was developed for T7-based E. coli expression systems. This medium was successfully employed in 96-well microtiter plates, test tubes, shake flasks, and 15-L bioreactor cultivations for production of different types of proteins achieving an average yield of 500 mg L(-1) product. Cell-specific protein concentrations and solubility were similar as during conventional isopropyl β-D-1-thiogalactopyranoside induction using Luria-Bertani broth. However, the final yield of target proteins was about four times higher, as a higher final biomass was achieved using this novel defined autoinduction broth. PMID:21698378

  7. Engineering of a high-throughput screening system to identify cellulosic biomass, pretreatments, and enzyme formulations that enhance sugar release.

    PubMed

    Studer, Michael H; DeMartini, Jaclyn D; Brethauer, Simone; McKenzie, Heather L; Wyman, Charles E

    2010-02-01

    The recalcitrance of cellulosic biomass, the only abundant, sustainable feedstock for making liquid fuels, is a primary obstacle to low cost biological processing, and development of more easily converted plants and more effective enzymes would be of great benefit. Because no single parameter describes recalcitrance, superior variants can only be identified by measuring sugar release from plants subjected to pretreatment and enzymatic hydrolysis. However, genetic modifications of plants coupled with molecular engineering of deconstruction proteins and definition of pretreatment conditions create a very large sample set, and previous methods for biomass pretreatment at elevated temperatures and pressures prevented use of a fully integrated high-throughput (HTP) screening pipeline. Herein, we report on the engineering of a novel HTP pretreatment system employing a 96 well-plate format that withstands extreme pretreatment conditions for rapid screening of biomass-enzyme-pretreatment combinations. This includes the development of new approaches to steam heating and water quenching the system that result in much faster heat up and cool down than previously possible and show consistent temperature histories across the multiwell plate. Coupled pretreatment and enzymatic hydrolysis performance of the well plate pretreatment system is shown to be consistent among the many wells in the device and also with performance of conventional tubular reactors.

  8. Models for rupture mechanics of plate boundaries and crustal deformation

    NASA Technical Reports Server (NTRS)

    Nur, A.

    1983-01-01

    The role of pull aparts and pushups in transcurrent systems, the rotation of faults and blocks within transcurrent fault systems, the role of accretion tectonics in plate boundary deformation, and power law creep behavior and the yielding at plate boundaries were investigated.

  9. 30 CFR 27.7 - Certification plate or label.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Certification plate or label. 27.7 Section 27.7... label. A certified methane-monitoring system or component thereof shall be identified with a certification plate or label which is attached to the system or component in a manner acceptable to MSHA....

  10. Principal visual word discovery for automatic license plate detection.

    PubMed

    Zhou, Wengang; Li, Houqiang; Lu, Yijuan; Tian, Qi

    2012-09-01

    License plates detection is widely considered a solved problem, with many systems already in operation. However, the existing algorithms or systems work well only under some controlled conditions. There are still many challenges for license plate detection in an open environment, such as various observation angles, background clutter, scale changes, multiple plates, uneven illumination, and so on. In this paper, we propose a novel scheme to automatically locate license plates by principal visual word (PVW), discovery and local feature matching. Observing that characters in different license plates are duplicates of each other, we bring in the idea of using the bag-of-words (BoW) model popularly applied in partial-duplicate image search. Unlike the classic BoW model, for each plate character, we automatically discover the PVW characterized with geometric context. Given a new image, the license plates are extracted by matching local features with PVW. Besides license plate detection, our approach can also be extended to the detection of logos and trademarks. Due to the invariance virtue of scale-invariant feature transform feature, our method can adaptively deal with various changes in the license plates, such as rotation, scaling, illumination, etc. Promising results of the proposed approach are demonstrated with an experimental study in license plate detection.

  11. PC-based car license plate reader

    NASA Astrophysics Data System (ADS)

    Hwang, Chung-Mu; Shu, Shyh-Yeong; Chen, Wen-Yu; Chen, Yie-Wern; Wen, Kuang-Pu

    1992-11-01

    A car license plate reader (CLPR) using fuzzy inference and neural network algorithm has been developed in Industrial Technology Research Institute (ITRI) and installed in highway toll stations to identify stolen cars. It takes an average of 0.7 seconds to recognize a car license plate by using a PC with 80486-50 CPU. The recognition rate of the system is about 97%. The techniques of CLPR include vehicle sensing, image grab control, optic pre- processing, lighting, and optic character recognition (OCR). The CLPR can be used in vehicle flow statistics, the checking of stolen vehicles, automatic charging systems in parking lots or garage management, and so on.

  12. This-layer chromatography/electrospray ionization triple-quadrupole linear ion trap mass spectrometry system: analysis of rhodamine dyes separated on reversed-phase C8 plates

    SciTech Connect

    Ford, Michael J; Kertesz, Vilmos; Van Berkel, Gary J

    2005-01-01

    The direct analysis of separated rhodamine dyes on reversed-phase C{sub 8} thin-layer chromatography plates using a surface sampling/electrospray emitter probe coupled with a triple-quadrupole linear ion trap mass spectrometer is presented. This report represents continuing work to advance the performance metrics and utility of this basic surface sampling electrospray mass spectrometry system for the analysis of thin-layer chromatography plates. Experimental results examining the role of sampling probe spray end configuration on liquid aspiration rate and gas-phase ion signal generated are discussed. The detection figures-of-merit afforded by full-scan, automated product ion and selected reaction monitoring modes of operation were examined. The effect of different eluting solvents on mass spectrum signal levels with the reversed-phase C{sub 8} plate was investigated. The combined effect of eluting solvent flow-rate and development lane surface scan rate on preservation of chromatographic resolution was also studied. Analysis of chromatographically separated red pen ink extracts from eight different pens using selected reaction monitoring demonstrated the potential of this surface sampling electrospray mass spectrometry system for targeted compound analysis with real samples.

  13. MyPlate Food Guide

    MedlinePlus

    ... follow throughout your life. 2. Fruits Like veggies, fruits contain vitamins, minerals, and fiber. The red section of MyPlate is slightly smaller than the green, but together fruits and veggies should fill half your plate. Whole ...

  14. What Are Growth Plate Injuries?

    MedlinePlus

    ... activities. Other reasons for growth plate injuries are:  Child abuse  Injury from extreme cold (for example, frostbite)  Radiation ( ... problems) treats most growth plate injuries. At other times, the child will see a pediatric orthopaedic surgeon (a doctor ...

  15. What Are Growth Plate Injuries?

    MedlinePlus

    ... activities. Other reasons for growth plate injuries are: Child abuse Injury from extreme cold (for example, frostbite) Radiation ( ... problems) treats most growth plate injuries. At other times, the child will see a pediatric orthopaedic surgeon (a doctor ...

  16. North American plate dynamics

    NASA Technical Reports Server (NTRS)

    Richardson, Randall M.; Reding, Lynn M.

    1991-01-01

    Deformation within the North American plate in response to various tectonic processes is modeled using an elastic finite element analysis. The tectonic processes considered in the modeling include ridge forces associated with the normal thermal evolution of oceanic lithosphere, shear and normal stresses transmitted across transforms, normal stresses transmitted across convergent boundaries, stresses due to horizontal density contrasts within the continent, and shear tractions applied along the base of the plate. Model stresses are calculated with respect to a lithostatic reference stress state. Shear stresses transmitted across transform boundaries along the San Andreas and Caribbean are small, of the order of 5-10 MPa. Also, compressive stresses of the order of 5-10 MPa transmitted across the major transforms improve the fit to the data. Compressive stresses across convergent margins along the Aleutians and the Middle America trench are important.

  17. Microchannel plate streak camera

    DOEpatents

    Wang, Ching L.

    1989-01-01

    An improved streak camera in which a microchannel plate electron multiplier is used in place of or in combination with the photocathode used in prior streak cameras. The improved streak camera is far more sensitive to photons (UV to gamma-rays) than the conventional x-ray streak camera which uses a photocathode. The improved streak camera offers gamma-ray detection with high temporal resolution. It also offers low-energy x-ray detection without attenuation inside the cathode. Using the microchannel plate in the improved camera has resulted in a time resolution of about 150 ps, and has provided a sensitivity sufficient for 1000 KeV x-rays.

  18. Microchannel plate streak camera

    DOEpatents

    Wang, C.L.

    1984-09-28

    An improved streak camera in which a microchannel plate electron multiplier is used in place of or in combination with the photocathode used in prior streak cameras. The improved streak camera is far more sensitive to photons (uv to gamma-rays) than the conventional x-ray streak camera which uses a photocathode. The improved streak camera offers gamma-ray detection with high temporal resolution. It also offers low-energy x-ray detection without attenuation inside the cathode. Using the microchannel plate in the improved camera has resulted in a time resolution of about 150 ps, and has provided a sensitivity sufficient for 1000 keV x-rays.

  19. Microchannel plate streak camera

    DOEpatents

    Wang, C.L.

    1989-03-21

    An improved streak camera in which a microchannel plate electron multiplier is used in place of or in combination with the photocathode used in prior streak cameras is disclosed. The improved streak camera is far more sensitive to photons (UV to gamma-rays) than the conventional x-ray streak camera which uses a photocathode. The improved streak camera offers gamma-ray detection with high temporal resolution. It also offers low-energy x-ray detection without attenuation inside the cathode. Using the microchannel plate in the improved camera has resulted in a time resolution of about 150 ps, and has provided a sensitivity sufficient for 1,000 KeV x-rays. 3 figs.

  20. Bipolar battery plate

    NASA Technical Reports Server (NTRS)

    Rowlette, John J. (Inventor)

    1985-01-01

    A liquid-impermeable plate (10) having throughplate conductivity with essentially zero resistance comprises an insulator sheet (12) having a series of spaced perforations (14) each of which contains a metal element (16) sealingly received into the perforation (14). A low-cost plate can readily be manufactured by punching a thermoplastic sheet (40) such as polypropylene with a punching tool (52), filling the apertures with lead spheres (63) having a diameter smaller than the holes (50) but larger than the thickness of the sheet, sweeping excess spheres (62) off the sheet with a doctor blade (60) and then pressing a heated platen (74) onto the sheet to swage the spheres into a cylindrical shape and melt the surrounding resin to form a liquid-impermeable collar (4) sealing the metal into the sheet.

  1. Large Deflections of Elastic Rectangular Plates

    NASA Astrophysics Data System (ADS)

    Razdolsky, A. G.

    2015-11-01

    It is known that elastic large deflections of thin plates are governed by von Karman nonlinear equations. The analytical solution of these equations in the general case is unfeasible. Samuel Levy, in 1942, showed that large deflections of the rectangular plate can be expressed as a double series of sine-shaped harmonics (deflection harmonics). However, this method gave no way of creating the computer algorithm of solving the problem. The stress function expression taken in the Levy's method must be revised to find the approach that takes into account of all possible products of deflection coefficients. The algorithm of solving the problem for the rectangular plate with an arbitrary aspect ratio under the action of the lateral distributed load is reported in this paper. The approximation of the plate deflection is taken in the form of double series proposed by Samuel Levy. However, the expression for the stress function is presented in the form that incorporates products of deflection coefficients in the explicit form in distinction to the Levy's expression. The number of harmonics in the deflection expression may be arbitrary. The algorithm provides composing the system of governing cubic equations, which includes the deflection coefficients in the explicit form. Solving the equation system is based on using the principle of minimum potential energy. A method of the gradient descent is applied to find the equilibrium state of the plate as the minimum point of the potential energy. A computer program is developed on the basis of the present algorithm. Numerical examples carried out for the plate model with 16 deflection harmonics illustrate the potentialities of the program. The results of solving the examples are presented in the graphical form for the plates with a different aspect ratio and may be used under designing thin-walled elements of airplane and ship structures.

  2. Plated wire memory subsystem

    NASA Technical Reports Server (NTRS)

    Reynolds, L.; Tweed, H.

    1972-01-01

    The work performed entailed the design, development, construction and testing of a 4000 word by 18 bit random access, NDRO plated wire memory for use in conjunction with a spacecraft imput/output unit and central processing unit. The primary design parameters, in order of importance, were high reliability, low power, volume and weight. A single memory unit, referred to as a qualification model, was delivered.

  3. Plate motion and deformation

    SciTech Connect

    Minster, B.; Prescott, W.; Royden, L.

    1991-02-01

    Our goal is to understand the motions of the plates, the deformation along their boundaries and within their interiors, and the processes that control these tectonic phenomena. In the broadest terms, we must strive to understand the relationships of regional and local deformation to flow in the upper mantle and the rheological, thermal and density structure of the lithosphere. The essential data sets which we require to reach our goal consist of maps of current strain rates at the earth's surface and the distribution of integrated deformation through time as recorded in the geologic record. Our success will depend on the effective synthesis of crustal kinematics with a variety of other geological and geophysical data, within a quantitative theoretical framework describing processes in the earth's interior. Only in this way can we relate the snapshot of current motions and earth structure provided by geodetic and geophysical data with long-term processes operating on the time scales relevant to most geological processes. The wide-spread use of space-based techniques, coupled with traditional geological and geophysical data, promises a revolution in our understanding of the kinematics and dynamics of plate motions over a broad range of spatial and temporal scales and in a variety of geologic settings. The space-based techniques that best address problems in plate motion and deformation are precise space-geodetic positioning -- on land and on the seafloor -- and satellite acquisition of detailed altimetric and remote sensing data in oceanic and continental areas. The overall science objectives for the NASA Solid Earth Science plan for the 1990's, are to Understand the motion and deformation of the lithosphere within and across plate boundaries'', and to understand the dynamics of the mantle, the structure and evolution of the lithosphere, and the landforms that result from local and regional deformation. 57 refs., 7 figs., 2 tabs.

  4. Martian plate tectonics

    NASA Astrophysics Data System (ADS)

    Sleep, N. H.

    1994-03-01

    The northern lowlands of Mars have been produced by plate tectonics. Preexisting old thick highland crust was subducted, while seafloor spreading produced thin lowland crust during late Noachian and Early Hesperian time. In the preferred reconstruction, a breakup margin extended north of Cimmeria Terra between Daedalia Planum and Isidis Planitia where the highland-lowland transition is relatively simple. South dipping subduction occured beneath Arabia Terra and east dipping subduction beneath Tharsis Montes and Tempe Terra. Lineations associated with Gordii Dorsum are attributed to ridge-parallel structures, while Phelegra Montes and Scandia Colles are interpreted as transfer-parallel structures or ridge-fault-fault triple junction tracks. Other than for these few features, there is little topographic roughness in the lowlands. Seafloor spreading, if it occurred, must have been relatively rapid. Quantitative estimates of spreading rate are obtained by considering the physics of seafloor spreading in the lower (approx. 0.4 g) gravity of Mars, the absence of vertical scarps from age differences across fracture zones, and the smooth axial topography. Crustal thickness at a given potential temperature in the mantle source region scales inversely with gravity. Thus, the velocity of the rough-smooth transition for axial topography also scales inversely with gravity. Plate reorganizations where young crust becomes difficult to subduct are another constraint on spreading age. Plate tectonics, if it occurred, dominated the thermal and stress history of the planet. A geochemical implication is that the lower gravity of Mars allows deeper hydrothermal circulation through cracks and hence more hydration of oceanic crust so that more water is easily subducted than on the Earth. Age and structural relationships from photogeology as well as median wavelength gravity anomalies across the now dead breakup and subduction margins are the data most likely to test and modify hypotheses

  5. Plates with Incompatible Prestrain

    NASA Astrophysics Data System (ADS)

    Bhattacharya, Kaushik; Lewicka, Marta; Schäffner, Mathias

    2016-07-01

    We study effective elastic behavior of the incompatibly prestrained thin plates, where the prestrain is independent of thickness and uniform through the plate's thickness h. We model such plates as three-dimensional elastic bodies with a prescribed pointwise stress-free state characterized by a Riemannian metric G, and seek the limiting behavior as {h to 0}. We first establish that when the energy per volume scales as the second power of h, the resulting {Γ} -limit is a Kirchhoff-type bending theory. We then show the somewhat surprising result that there exist non-immersible metrics G for whom the infimum energy (per volume) scales smaller than h 2. This implies that the minimizing sequence of deformations carries nontrivial residual three-dimensional energy but it has zero bending energy as seen from the limit Kirchhoff theory perspective. Another implication is that other asymptotic scenarios are valid in appropriate smaller scaling regimes of energy. We characterize the metrics G with the above property, showing that the zero bending energy in the Kirchhoff limit occurs if and only if the Riemann curvatures R 1213, R 1223 and R 1212 of G vanish identically. We illustrate our findings with examples; of particular interest is an example where {G_{2 × 2}}, the two-dimensional restriction of G, is flat but the plate still exhibits the energy scaling of the Föppl-von Kármán type. Finally, we apply these results to a model of nematic glass, including a characterization of the condition when the metric is immersible, for {G = Id3 + γ n ⊗ n} given in terms of the inhomogeneous unit director field distribution { n in R^3}.

  6. Calibration and equivalency analysis of image plate scanners

    SciTech Connect

    Williams, G. Jackson Maddox, Brian R.; Chen, Hui; Kojima, Sadaoki; Millecchia, Matthew

    2014-11-15

    A universal procedure was developed to calibrate image plate scanners using radioisotope sources. Techniques to calibrate scanners and sources, as well as cross-calibrate scanner models, are described to convert image plate dosage into physical units. This allows for the direct comparison of quantitative data between any facility and scanner. An empirical relation was also derived to establish sensitivity response settings for arbitrary gain settings. In practice, these methods may be extended to any image plate scanning system.

  7. Calibration and equivalency analysis of image plate scanners.

    PubMed

    Williams, G Jackson; Maddox, Brian R; Chen, Hui; Kojima, Sadaoki; Millecchia, Matthew

    2014-11-01

    A universal procedure was developed to calibrate image plate scanners using radioisotope sources. Techniques to calibrate scanners and sources, as well as cross-calibrate scanner models, are described to convert image plate dosage into physical units. This allows for the direct comparison of quantitative data between any facility and scanner. An empirical relation was also derived to establish sensitivity response settings for arbitrary gain settings. In practice, these methods may be extended to any image plate scanning system. PMID:25430350

  8. The Hydrothermal System at Home Plate in Gusev Crater, Mars: Formation of High Silica Material by Acid-Sulfate Alteration of Basalt

    NASA Technical Reports Server (NTRS)

    Morris, R. V.; Ming, D. W.; Gellert, R.; Yen, A.; Clark, B. C.; Gnaff, T. G.; Arvidson, R. E.; Squyres, S. W.

    2008-01-01

    The Alpha Particle X-ray Spectrometer (APXS) instrument on the Mars Exploration Rover (MER) Spirit measured three targets on or adjacent to Home Plate in Gusev Crater that have unusually high SiO2 concentrations (68% to 91%), unusually low FeO concentrations (1% to 7%, with total Fe as FeO), and unusually high TiO2/FeO ratios (0.2 to 1.2 by weight) [1]. Two targets (Kenosha Comets and Lefty Ganote) are located on high albedo soil (Gertrude Weise) that was exposed by the rover wheels, and one target is a float rock called Fuzzy Smith. Kenosha Comets has the highest SiO2 concentration, lowest FeO concentration, and highest TiO2/FeO ratio. Mineralogical evidence from the MER Miniature Thermal Emission Spectrometer (Mini-TES) suggests that the SiO2 is present as amorphous (noncrystalline) SiO2 at Gertrude Weise and nearby targets [2,3]. Mini-TES data were not acquired for Fuzzy Smith. Home Plate is considered to have an explosive volcanic origin, resulting when basaltic magma came into contact with ground water or ice [4]. Within 50 m to 1 km of Home Plate are sulfate rich soil deposits (Paso Robles class soils with 22-35% SO3) which are considered to be probable fumarolic and/or hydrothermal deposits associated with the volcanism [5]. We develop the model here, suggested by [5], that the high-silica materials are another manifestation of acid-sulfate processes associated with fumarolic and hydrothermal activity at Home Plate. This is done by analogy with basaltic materials altered by acid sulfate processes on the Island of Hawaii.

  9. Symmetries in laminated composite plates

    NASA Technical Reports Server (NTRS)

    Noor, A. K.

    1976-01-01

    The different types of symmetry exhibited by laminated anisotropic fibrous composite plates are identified and contrasted with the symmetries of isotropic and homogeneous orthotropic plates. The effects of variations in the fiber orientation and the stacking sequence of the layers on the symmetries exhibited by composite plates are discussed. Both the linear and geometrically nonlinear responses of the plates are considered. A simple procedure is presented for exploiting the symmetries in the finite element analysis. Examples are given of square, skew and polygonal plates where use of symmetry concepts can significantly reduce the scope and cost of analysis.

  10. Hypervelocity impact on shielded plates

    NASA Technical Reports Server (NTRS)

    Smith, James P.

    1993-01-01

    A ballistic limit equation for hypervelocity impact on thin plates is derived analytically. This equation applies to cases of impulsive impact on a plate that is protected by a multi-shock shield, and it is valid in the range of velocity above 6 km/s. Experimental tests were conducted at the NASA Johnson Space Center on square aluminum plates. Comparing the center deflections of these plates with the theoretical deflections of a rigid-plastic plate subjected to a blast load, one determines the dynamic yield strength of the plate material. The analysis is based on a theory for the expansion of the fragmented projectile and on a simple failure criterion. Curves are presented for the critical projectile radius versus the projectile velocity, and for the critical plate thickness versus the velocity. These curves are in good agreement with curves that have been generated empirically.

  11. Fuel cell end plate structure

    DOEpatents

    Guthrie, Robin J.; Katz, Murray; Schroll, Craig R.

    1991-04-23

    The end plates (16) of a fuel cell stack (12) are formed of a thin membrane. Pressure plates (20) exert compressive load through insulation layers (22, 26) to the membrane. Electrical contact between the end plates (16) and electrodes (50, 58) is maintained without deleterious making and breaking of electrical contacts during thermal transients. The thin end plate (16) under compressive load will not distort with a temperature difference across its thickness. Pressure plate (20) experiences a low thermal transient because it is insulated from the cell. The impact on the end plate of any slight deflection created in the pressure plate by temperature difference is minimized by the resilient pressure pad, in the form of insulation, therebetween.

  12. A unidirectional subwavelength focusing near-field plate

    SciTech Connect

    Imani, Mohammadreza F.; Grbic, Anthony

    2014-01-28

    Near-field plates consist of non-periodically patterned surfaces that can overcome the diffraction limit and confine electromagnetic fields to subwavelength dimensions. Previous near-field plates experimentally demonstrated extreme field tailoring capabilities. However, their performance suffered from radiation/reflection in undesired directions, those other than the subwavelength focus. This issue can limit the practical use of near-field plates. In this paper, we address this issue by designing a unidirectional near-field plate that can form a subwavelength focal pattern, while suppressing the field radiated/reflected in other directions. The design and operation of the proposed unidirectional near-field plate are verified through full-wave simulation. The unidirectional near-field plate may find application in high resolution imaging and probing, high density data storage, and wireless power transfer systems. As an example, its utility as a high resolution probe is demonstrated through full-wave electromagnetic simulation.

  13. Generation of Plates In Numerical Mantle Convection Models

    NASA Astrophysics Data System (ADS)

    Stein, C.; Hansen, U.

    A threedimensional numerical model is employed to investigate with an appropriate rheology how the mantle convection system organizes itself into a state, exhibiting essential features of plate tectonics. While a strongly temperature dependent viscosity leads to a stagnant lid, mobilization of the surface appears if an additional yield-stress criterion is taken into account. During short periods, parts of the surface move like plates. These periods are interrupted by phases in which a stagnant lid exists. Besides plate-like motion we observe other features like the migration of subduction-zones. Adding further a pressure dependence of the viscosity leads to change to a more con- tinuous plate-like behaviour. Once plates have formed, the surface moves essentially steady throughout the modelled time. This model evolves into a state displaying ex- tended rigidly moving plates, surrounded by localized areas with high deformation.

  14. Formation of Plates in Numerical Mantle Convection Models

    NASA Astrophysics Data System (ADS)

    Stein, C.; Hansen, U.

    2001-12-01

    In a threedimensional numerical model we demonstrate that with an appropriate rheology the mantle convection system organizes itself into a state, exhibiting essential features of plate tectonics. While a strongly temperature-dependent viscosity leads to a stagnant lid, mobilization of the surface appears if an additional yield-stress criterion is taken into account. During short periods, parts of the surface move like plates. These periods are interrupted by phases in which a stagnant lid exists. Besides plate-like motion we observe other features like the migration of subduction-zones. Adding further a pressure dependence of the viscosity leads to change from the episodic to a more continuous plate-like behavior. Once plates have formed, the surface moves essentially steady throughout the modelled time. This models evolves into a state displaying extended rigidly moving plates, surrounded by localized areas with high deformation.

  15. Comparison of treatment of unstable intra articular fractures of distal radius with locking plate versus non-locking plate fixation

    PubMed Central

    Kumar, Sunil; Chopra, R.K.; Sehrawat, Sunil; Lakra, Akshay

    2014-01-01

    Introduction Unstable intra articular fractures of distal radius are frequently being managed with open reduction and internal fixation. Of late in some biomechanical studies locking plates have been shown to be better in terms of maintenance of radiological parameters in comparison to non-locking plates. We conducted this study to know whether this biomechanical superiority of locking plates is converted in to better clinical outcomes. Materials and methods A study was conducted in 60 patients (30 in each group) with unstable intra articular fractures of distal radius who were treated by open reduction and internal fixation with locking plates and non-locking plates. Patients were evaluated for radiological parameters (intra articular step off, radial height, radial tilt, volar tilt) and functional parameters (flexion, extension, radial deviation, ulnar deviation, pronation, supination grip strength) at two year follow up. Overall outcome was evaluated by scoring systems of Gartland and Werley and modified Green O' Brien. Results The change in radiological parameters from immediate post op to latest at two year in locking plate group was not significant for radial height, radial tilt, volar tilt, but ulnar variance whereas in non-locking plate there was significant change in radial height, volar tilt, ulnar variance but no significant change in radial inclination. In clinical and functional outcome no significant difference was found at two year follow up. Conclusions Locking plates maintain the radiological parameters better than non-locking plates but functional outcome are same for both plates at two year after surgery. PMID:25983474

  16. 30 CFR 27.7 - Certification plate or label.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... APPROVAL OF MINING PRODUCTS METHANE-MONITORING SYSTEMS General Provisions § 27.7 Certification plate or label. A certified methane-monitoring system or component thereof shall be identified with...

  17. 30 CFR 27.7 - Certification plate or label.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... APPROVAL OF MINING PRODUCTS METHANE-MONITORING SYSTEMS General Provisions § 27.7 Certification plate or label. A certified methane-monitoring system or component thereof shall be identified with...

  18. 30 CFR 27.7 - Certification plate or label.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... APPROVAL OF MINING PRODUCTS METHANE-MONITORING SYSTEMS General Provisions § 27.7 Certification plate or label. A certified methane-monitoring system or component thereof shall be identified with...

  19. Shuttle plate braiding machine

    NASA Technical Reports Server (NTRS)

    Huey, Jr., Cecil O. (Inventor)

    1994-01-01

    A method and apparatus for moving yarn in a selected pattern to form a braided article. The apparatus includes a segmented grid of stationary support elements and a plurality of shuttles configured to carry yarn. The shuttles are supported for movement on the grid assembly and each shuttle includes a retractable plunger for engaging a reciprocating shuttle plate that moves below the grid assembly. Such engagement at selected times causes the shuttles to move about the grid assembly in a selected pattern to form a braided article of a particular geometry.

  20. Rotary sequencing valve with flexible port plate

    DOEpatents

    Wagner, Glenn Paul

    2005-05-10

    Rotary sequencing valve comprising a rotor having a rotor face rotatable about an axis perpendicular to the rotor face, wherein the rotor face has a plurality of openings, one or more of which are disposed at a selected radial distance from the axis, and wherein the rotor includes at least one passage connecting at least one pair of the plurality of openings. The valve includes a flexible port plate having a first side and a second side, wherein the first side faces the rotor and engages the rotor such that the flexible port plate can be rotated coaxially by the rotor and can move axially with respect to the rotor, wherein the flexible port plate has a plurality of ports between the first and second sides, which ports are aligned with the openings in the rotor face. The valve also includes a stator having a stator face disposed coaxially with the rotor and the flexible port plate, wherein the second side of the flexible port plate is in sealable, slidable rotary contact with the stator face, wherein the stator face has a plurality of openings, some of which are disposed at the selected radial distance from the axis, and wherein the plurality of openings extend as passages through the stator. The valve may be used in pressure or temperature swing adsorption systems.

  1. Fuel Cell Thermal Management Through Conductive Cooling Plates

    NASA Technical Reports Server (NTRS)

    Colozza, Anthony J.; Burke, Kenneth A.

    2008-01-01

    An analysis was performed to evaluate the concept of utilizing conductive cooling plates to remove heat from a fuel cell stack, as opposed to a conventional internal cooling loop. The potential advantages of this type of cooling system are reduced stack complexity and weight and increased reliability through the reduction of the number of internal fluid seals. The conductive cooling plates would extract heat from the stack transferring it to an external coolant loop. The analysis was performed to determine the required thickness of these plates. The analysis was based on an energy balance between the thermal energy produced within the stack and the heat removal from the cooling plates. To accomplish the energy balance, the heat flow into and along the plates to the cooling fluid was modeled. Results were generated for various numbers of cells being cooled by a single cooling plate. The results provided cooling plate thickness, mass, and operating temperature of the plates. It was determined that utilizing high-conductivity pyrolitic graphite cooling plates can provide a specific cooling capacity (W/kg) equivalent to or potentially greater than a conventional internal cooling loop system.

  2. Plate tectonics drive tropical reef biodiversity dynamics.

    PubMed

    Leprieur, Fabien; Descombes, Patrice; Gaboriau, Théo; Cowman, Peter F; Parravicini, Valeriano; Kulbicki, Michel; Melián, Carlos J; de Santana, Charles N; Heine, Christian; Mouillot, David; Bellwood, David R; Pellissier, Loïc

    2016-01-01

    The Cretaceous breakup of Gondwana strongly modified the global distribution of shallow tropical seas reshaping the geographic configuration of marine basins. However, the links between tropical reef availability, plate tectonic processes and marine biodiversity distribution patterns are still unknown. Here, we show that a spatial diversification model constrained by absolute plate motions for the past 140 million years predicts the emergence and movement of diversity hotspots on tropical reefs. The spatial dynamics of tropical reefs explains marine fauna diversification in the Tethyan Ocean during the Cretaceous and early Cenozoic, and identifies an eastward movement of ancestral marine lineages towards the Indo-Australian Archipelago in the Miocene. A mechanistic model based only on habitat-driven diversification and dispersal yields realistic predictions of current biodiversity patterns for both corals and fishes. As in terrestrial systems, we demonstrate that plate tectonics played a major role in driving tropical marine shallow reef biodiversity dynamics. PMID:27151103

  3. Astrometric properties of the Tautenburg Plate Scanner

    NASA Astrophysics Data System (ADS)

    Brunzendorf, Jens; Meusinger, Helmut

    The Tautenburg Plate Scanner (TPS) is an advanced plate-measuring machine run by the Thüringer Landessternwarte Tautenburg (Karl Schwarzschild Observatory), where the machine is housed. It is capable of digitising photographic plates up to 30 cm × 30 cm in size. In our poster, we reported on tests and preliminary results of its astrometric properties. The essential components of the TPS consist of an x-y table movable between an illumination system and a direct imaging system. A telecentric lens images the light transmitted through the photographic emulsion onto a CCD line of 6000 pixels of 10 µm square size each. All components are mounted on a massive air-bearing table. Scanning is performed in lanes of up to 55 mm width by moving the x-y table in a continuous drift-scan mode perpendicular to the CCD line. The analogue output from the CCD is digitised to 12 bit with a total signal/noise ratio of 1000 : 1, corresponding to a photographic density range of three. The pixel map is produced as a series of optionally overlapping lane scans. The pixel data are stored onto CD-ROM or DAT. A Tautenburg Schmidt plate 24 cm × 24 cm in size is digitised within 2.5 hours resulting in 1.3 GB of data. Subsequent high-level data processing is performed off-line on other computers. During the scanning process, the geometry of the optical components is kept fixed. The optimal focussing of the optics is performed prior to the scan. Due to the telecentric lens refocussing is not required. Therefore, the main source of astrometric errors (beside the emulsion itself) are mechanical imperfections in the drive system, which have to be divided into random and systematic ones. The r.m.s. repeatability over the whole plate as measured by repeated scans of the same plate is about 0.5 µm for each axis. The mean plate-to-plate accuracy of the object positions on two plates with the same epoch and the same plate centre has been determined to be about 1 µm. This accuracy is comparable to

  4. Plate tectonics drive tropical reef biodiversity dynamics.

    PubMed

    Leprieur, Fabien; Descombes, Patrice; Gaboriau, Théo; Cowman, Peter F; Parravicini, Valeriano; Kulbicki, Michel; Melián, Carlos J; de Santana, Charles N; Heine, Christian; Mouillot, David; Bellwood, David R; Pellissier, Loïc

    2016-05-06

    The Cretaceous breakup of Gondwana strongly modified the global distribution of shallow tropical seas reshaping the geographic configuration of marine basins. However, the links between tropical reef availability, plate tectonic processes and marine biodiversity distribution patterns are still unknown. Here, we show that a spatial diversification model constrained by absolute plate motions for the past 140 million years predicts the emergence and movement of diversity hotspots on tropical reefs. The spatial dynamics of tropical reefs explains marine fauna diversification in the Tethyan Ocean during the Cretaceous and early Cenozoic, and identifies an eastward movement of ancestral marine lineages towards the Indo-Australian Archipelago in the Miocene. A mechanistic model based only on habitat-driven diversification and dispersal yields realistic predictions of current biodiversity patterns for both corals and fishes. As in terrestrial systems, we demonstrate that plate tectonics played a major role in driving tropical marine shallow reef biodiversity dynamics.

  5. Plate tectonics drive tropical reef biodiversity dynamics

    PubMed Central

    Leprieur, Fabien; Descombes, Patrice; Gaboriau, Théo; Cowman, Peter F.; Parravicini, Valeriano; Kulbicki, Michel; Melián, Carlos J.; de Santana, Charles N.; Heine, Christian; Mouillot, David; Bellwood, David R.; Pellissier, Loïc

    2016-01-01

    The Cretaceous breakup of Gondwana strongly modified the global distribution of shallow tropical seas reshaping the geographic configuration of marine basins. However, the links between tropical reef availability, plate tectonic processes and marine biodiversity distribution patterns are still unknown. Here, we show that a spatial diversification model constrained by absolute plate motions for the past 140 million years predicts the emergence and movement of diversity hotspots on tropical reefs. The spatial dynamics of tropical reefs explains marine fauna diversification in the Tethyan Ocean during the Cretaceous and early Cenozoic, and identifies an eastward movement of ancestral marine lineages towards the Indo-Australian Archipelago in the Miocene. A mechanistic model based only on habitat-driven diversification and dispersal yields realistic predictions of current biodiversity patterns for both corals and fishes. As in terrestrial systems, we demonstrate that plate tectonics played a major role in driving tropical marine shallow reef biodiversity dynamics. PMID:27151103

  6. Plate tectonics drive tropical reef biodiversity dynamics

    NASA Astrophysics Data System (ADS)

    Leprieur, Fabien; Descombes, Patrice; Gaboriau, Théo; Cowman, Peter F.; Parravicini, Valeriano; Kulbicki, Michel; Melián, Carlos J.; de Santana, Charles N.; Heine, Christian; Mouillot, David; Bellwood, David R.; Pellissier, Loïc

    2016-05-01

    The Cretaceous breakup of Gondwana strongly modified the global distribution of shallow tropical seas reshaping the geographic configuration of marine basins. However, the links between tropical reef availability, plate tectonic processes and marine biodiversity distribution patterns are still unknown. Here, we show that a spatial diversification model constrained by absolute plate motions for the past 140 million years predicts the emergence and movement of diversity hotspots on tropical reefs. The spatial dynamics of tropical reefs explains marine fauna diversification in the Tethyan Ocean during the Cretaceous and early Cenozoic, and identifies an eastward movement of ancestral marine lineages towards the Indo-Australian Archipelago in the Miocene. A mechanistic model based only on habitat-driven diversification and dispersal yields realistic predictions of current biodiversity patterns for both corals and fishes. As in terrestrial systems, we demonstrate that plate tectonics played a major role in driving tropical marine shallow reef biodiversity dynamics.

  7. Low-distortion resistive anodes for two-dimensional position-sensitive MCP systems. [Microchannel Plates for ion, electron and photon image sensing and conversion

    NASA Technical Reports Server (NTRS)

    Lampton, M.; Carlson, C. W.

    1979-01-01

    Microchannel plates (MCPs) are frequently used with resistive anodes to detect charged particles or photons and yield analog signals from which event positions can be decoded. The paper discusses a four-corner concave circular arc terminated resistive anode that permits theoretically distortionless encoding of Cartesian event positions into pulse charge ratios. The theory of the circular arc terminated anode is discussed along with anode design and performance. Electron beam images obtained by using such an anode are presented to confirm the usefulness of the approach.

  8. Effect of calcium ions on the evolution of biofouling by Bacillus subtilis in plate heat exchangers simulating the heat pump system used with treated sewage in the 2008 Olympic Village.

    PubMed

    Tian, Lei; Chen, Xiao Dong; Yang, Qian Peng; Chen, Jin Chun; Shi, Lin; Li, Qiong

    2012-06-01

    Heat pump systems using treated sewage water as the heat source were used in the Beijing Olympic Village for domestic heating and cooling. However, considerable biofouling occurred in the plate heat exchangers used in the heat pump system, greatly limiting the system efficiency. This study investigates the biofouling characteristics using a plate heat exchanger in parallel with a flow cell system to focus on the effect of calcium ions on the biofilm development. The interactions between the microorganisms and Ca(2+) enhances both the extent and the rate of biofilm development with increasing Ca(2+) concentration, leading to increased heat transfer and flow resistances. Three stages of biofouling development were identified in the presence of Ca(2+) from different biofouling mass growth rates with an initial stage, a rapid growth stage and an extended growth stage. Each growth stage had different biofouling morphologies influenced by the Ca(2+) concentration. The effects of Ca(2+) on the biofouling heat transfer and flow resistances had a synergistic effect related to both the biofouling mass and the morphology. The effect of Ca(2+) on the biofouling development was most prominent during the rapid growth stage. PMID:22391321

  9. Effect of calcium ions on the evolution of biofouling by Bacillus subtilis in plate heat exchangers simulating the heat pump system used with treated sewage in the 2008 Olympic Village.

    PubMed

    Tian, Lei; Chen, Xiao Dong; Yang, Qian Peng; Chen, Jin Chun; Shi, Lin; Li, Qiong

    2012-06-01

    Heat pump systems using treated sewage water as the heat source were used in the Beijing Olympic Village for domestic heating and cooling. However, considerable biofouling occurred in the plate heat exchangers used in the heat pump system, greatly limiting the system efficiency. This study investigates the biofouling characteristics using a plate heat exchanger in parallel with a flow cell system to focus on the effect of calcium ions on the biofilm development. The interactions between the microorganisms and Ca(2+) enhances both the extent and the rate of biofilm development with increasing Ca(2+) concentration, leading to increased heat transfer and flow resistances. Three stages of biofouling development were identified in the presence of Ca(2+) from different biofouling mass growth rates with an initial stage, a rapid growth stage and an extended growth stage. Each growth stage had different biofouling morphologies influenced by the Ca(2+) concentration. The effects of Ca(2+) on the biofouling heat transfer and flow resistances had a synergistic effect related to both the biofouling mass and the morphology. The effect of Ca(2+) on the biofouling development was most prominent during the rapid growth stage.

  10. 30 CFR 27.7 - Certification plate or label.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Certification plate or label. 27.7 Section 27.7 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS METHANE-MONITORING SYSTEMS General Provisions § 27.7 Certification plate or label. A certified...

  11. Optimization of Salmonella Typhi biofilm assay on polypropylene microtiter plates using response surface methodology.

    PubMed

    Ganjali Dashti, M; Abdeshahian, P; Sudesh, K; Phua, K K

    2016-01-01

    The objective of this study was to develop an optimized assay for Salmonella Typhi biofilm that mimics the environment of the gallbladder as an experimental model for chronic typhoid fever. Multi-factorial assays are difficult to optimize using traditional one-factor-at-a-time optimization methods. Response surface methodology (RSM) was used to optimize six key variables involved in S. Typhi biofilm formation on cholesterol-coated polypropylene 96-well microtiter plates. The results showed that bile (1.22%), glucose (2%), cholesterol (0.05%) and potassium chloride (0.25%) were critical factors affecting the amount of biofilm produced, but agitation (275 rpm) and sodium chloride (0.5%) had antagonistic effects on each other. Under these optimum conditions the maximum OD reading for biofilm formation was 3.4 (λ600 nm), and the coefficients of variation for intra-plate and inter-plate assays were 3% (n = 20) and 5% (n = 8), respectively. These results showed that RSM is an effective approach for biofilm assay optimization. PMID:26963754

  12. Plating on difficult-to-plate metals: what's new

    SciTech Connect

    Wiesner, H.J.

    1980-07-30

    Some of the changes since 1970 in procedures for plating on such materials as titanium, molybdenum, silicon, aluminum, and gallium arsenide are summarized. While basic procedures for plating some of these materials were developed as many as 30 to 40 years ago, changes in the end uses of the plated products have necessitated new plating processes. In some cases, vacuum techniques - such as ion bombardment, ion implantation, and vacuum metallization - have been introduced to improve the adhesion of electrodeposits. In other cases, these techniques have been used to deposit materials upon which electrodeposits are required.

  13. Waste minimization in chrome plating

    SciTech Connect

    Scheuer, J.; Walter, K.; Nastasi, M.

    1996-09-01

    This is the final report of a one year laboratory directed research and development project at the Los Alamos National Laboratory (LANL). Traditional wet chemical electroplating techniques utilize toxic materials and pose environmental hazards in the disposal of primary baths and waste waters. Pollutants include metals and nonmetals, such as oil, grease, phosphates, and toxic and organic compounds. This project is focused on development of plasma source ion implantation (PSII), a novel and cost-effective surface modification technique, to minimize and ultimately eliminate waste generated in chrome plating. We are collaborating with and industrial partner to design material systems, utilize the PSII processes in existing Los Alamos experimental facilities, and analyze both material and performance characteristics.

  14. LOWLID FORMATION AND PLATE TECTONICS ON EXOPLANETS

    NASA Astrophysics Data System (ADS)

    Stamenkovic, V.; Noack, L.; Breuer, D.

    2009-12-01

    The last years of astronomical observation have opened the doors to a universe filled with extrasolar planets. Detection techniques still only offer the possibility to detect mainly Super-Earths above five Earth masses. But detection techniques do steadily improve and are offering the possibility to detect even smaller planets. The observations show that planets seem to exist in many possible sizes just as the planets and moons of our own solar system do. It is only a natural question to ask if planetary mass has an influence on some key habitability factors such as on plate tectonics, allowing us to test which exoplanets might be more likely habitable than others, and allowing us to understand if plate tectonics on Earth is a stable or a critical, instable process that could easily be perturbed. Here we present results derived from 1D parameterized thermal evolution and 2D/3D computer models, showing how planetary mass influences the propensity of plate tectonics for planets with masses ranging from 0.1 to 10 Earth masses. Lately [2, 3] studied the effect of planetary mass on the ability to break plates and hence initiate plate tectonics - but both derived results contradictory to the other. We think that one of the reasons why both studies [2, 3] are not acceptable in their current form is partly due to an oversimplification. Both treated viscosity only temperature-dependent but neglected the effect pressure has on enlarging the viscosity in the deep mantle. More massive planets have therefore a stronger pressure-viscosity-coupling making convection at high pressures sluggish or even impossible. For planets larger than two Earth masses we observe that a conductive lid (termed low-lid) forms above the core-mantle boundary and thus reduces the effective convective part of the mantle when including a pressure-dependent term into the viscosity laws as shown in [1]. Moreover [2, 3] use time independent steady state models neglecting the fact that plate tectonics is a

  15. Tectonics of the Easter plate

    NASA Technical Reports Server (NTRS)

    Engeln, J. F.; Stein, S.

    1984-01-01

    A new model for the Easter plate is presented in which rift propagation has resulted in the formation of a rigid plate between the propagating and dying ridges. The distribution of earthquakes, eleven new focal mechanisms, and existing bathymetric and magnetic data are used to describe the tectonics of this area. Both the Easter-Nazca and Easter-Pacific Euler poles are sufficiently close to the Easter plate to cause rapid changes in rates and directions of motion along the boundaries. The east and west boundaries are propagating and dying ridges; the southwest boundary is a slow-spreading ridge and the northern boundary is a complex zone of convergent and transform motion. The Easter plate may reflect the tectonics of rift propagation on a large scale, where rigid plate tectonics requires boundary reorientation. Simple schematic models to illustrate the general features and processes which occur at plates resulting from large-scale rift propagation are used.

  16. Localised Plate Motion on Venus

    NASA Astrophysics Data System (ADS)

    Ghail, R. C.

    1996-03-01

    The volcanic and tectonic features observed in Dali Vinculum, Parga Vinculum and Imdr Regio are concentrated at long, narrow, curvilinear zones, with relatively minor volcanism and tectonism between these zones. These zones, whilst more diffuse than terrestrial plate boundaries, nevertheless define the margins of tectonic plates. In contrast to Earth, however, it appears that venusian plates are neither created nor destroyed by lateral motion. Rather, plates are thinned and intruded at vincula plate boundaries, vertically accreted by small-scale intra-plate (planitia) volcanism and perhaps destroyed by delamination of thickened crust in tesserae and montane regions such as Thetis Regio and Ishtar Terra. The diversity in age both between and within these three areas together with the evidence for infrequent, small scale resurfacing in the planitiae are difficult to reconcile with a non-uniformitarian geological process.

  17. Channel plate for DNA sequencing

    DOEpatents

    Douthart, R.J.; Crowell, S.L.

    1998-01-13

    This invention is a channel plate that facilitates data compaction in DNA sequencing. The channel plate has a length, a width and a thickness, and further has a plurality of channels that are parallel. Each channel has a depth partially through the thickness of the channel plate. Additionally an interface edge permits electrical communication across an interface through a buffer to a deposition membrane surface. 15 figs.

  18. Ion plating for the future

    NASA Technical Reports Server (NTRS)

    Spalvins, T.

    1981-01-01

    The ion plating techniques are classified relative to the instrumental set up, evaporation media, and mode of transport. A distinction is drawn between the low vacuum (plasma) and high vacuum (ion beam) techniques. Ion plating technology is discussed at the fundamental and industrial level. At the fundamental level, the capabilities and limitations of the plasma (evaporant flux) and film characteristics are evaluated. And on the industrial level, the performance and potential uses of ion plated films are discussed.

  19. Plate heat exchanger design theory

    NASA Astrophysics Data System (ADS)

    Shah, R. K.; Wanniarachchi, A. S.

    Plate heat exchangers are commonly used in hygienic applications as well as in chemical processing and other industrial applications. Pertinent information on plate exchangers from a designer's point of view is summarized to provide a basic insight into performance behavior of chevron plates. Basic design methods are presented and a method of coupling between heat transfer and pressure drop is introduced. A step by step design procedure for rating and sizing problems is outlined.

  20. Channel plate for DNA sequencing

    DOEpatents

    Douthart, Richard J.; Crowell, Shannon L.

    1998-01-01

    This invention is a channel plate that facilitates data compaction in DNA sequencing. The channel plate has a length, a width and a thickness, and further has a plurality of channels that are parallel. Each channel has a depth partially through the thickness of the channel plate. Additionally an interface edge permits electrical communication across an interface through a buffer to a deposition membrane surface.

  1. On electrostatically actuated NEMS/MEMS circular plates

    NASA Astrophysics Data System (ADS)

    Caruntu, Dumitru I.; Alvarado, Iris

    2011-04-01

    This paper deals with electrostatically actuated micro and nano-electromechanical (MEMS/NEMS) circular plates. The system under investigation consists of two bodies, a deformable and conductive circular plate placed above a fixed, rigid and conductive ground plate. The deformable circular plate is electrostatically actuated by applying an AC voltage between the two plates. Nonlinear parametric resonance and pull-in occur at certain frequencies and relatively large AC voltage, respectively. Such phenomena are useful for applications such as sensors, actuators, switches, micro-pumps, micro-tweezers, chemical and mass sensing, and micro-mirrors. A mathematical model of clamped circular MEMS/NEMS electrostatically actuated plates has been developed. Since the model is in the micro- and nano-scale, surface forces, van der Waals and/or Casimir, acting on the plate are included. A perturbation method, the Method of Multiple Scales (MMS), is used for investigating the case of weakly nonlinear MEMS/NEMS circular plates. Two time scales, fast and slow, are considered in this work. The amplitude-frequency and phase-frequency response of the plate in the case of primary resonance are obtained and discussed.

  2. Glass-bead peen plating

    NASA Technical Reports Server (NTRS)

    Graves, J. R.

    1974-01-01

    Peen plating of aluminum, copper, and nickel powders was investigated. Only aluminum was plated successfully within the range of peen plating conditions studied. Optimum plating conditions for aluminum were found to be: (1) bead/powder mixture containing 25 to 35% powder by weight, (2) peening intensity of 0.007A as measured by Almen strip, and (3) glass impact bead diameter of at least 297 microns (0.0117 inches) for depositing-100 mesh aluminum powder. No extensive cleaning or substrate preparation is required beyond removing loose dirt or heavy oil.

  3. True Shear Parallel Plate Viscometer

    NASA Technical Reports Server (NTRS)

    Ethridge, Edwin; Kaukler, William

    2010-01-01

    This viscometer (which can also be used as a rheometer) is designed for use with liquids over a large temperature range. The device consists of horizontally disposed, similarly sized, parallel plates with a precisely known gap. The lower plate is driven laterally with a motor to apply shear to the liquid in the gap. The upper plate is freely suspended from a double-arm pendulum with a sufficiently long radius to reduce height variations during the swing to negligible levels. A sensitive load cell measures the shear force applied by the liquid to the upper plate. Viscosity is measured by taking the ratio of shear stress to shear rate.

  4. Carbon-assisted flyer plates

    DOEpatents

    Stahl, David B.; Paisley, Dennis L.

    1994-01-01

    A laser driven flyer plate utilizing an optical fiber connected to a laser. The end of the optical fiber has a layer of carbon and a metal layer deposited onto it. The carbon layer provides the laser induced plasma which is superior to the plasma produced from most metals. The carbon layer plasma is capable of providing a flatter flyer plate, converting more of the laser energy to driving plasma, promoting a higher flyer plate acceleration, and providing a more uniform pulse behind the plate. In another embodiment, the laser is in optical communication with a substrate onto which a layer of carbon and a layer of metal have been deposited.

  5. Intermittent plate tectonics?

    PubMed

    Silver, Paul G; Behn, Mark D

    2008-01-01

    Although it is commonly assumed that subduction has operated continuously on Earth without interruption, subduction zones are routinely terminated by ocean closure and supercontinent assembly. Under certain circumstances, this could lead to a dramatic loss of subduction, globally. Closure of a Pacific-type basin, for example, would eliminate most subduction, unless this loss were compensated for by comparable subduction initiation elsewhere. Given the evidence for Pacific-type closure in Earth's past, the absence of a direct mechanism for termination/initiation compensation, and recent data supporting a minimum in subduction flux in the Mesoproterozoic, we hypothesize that dramatic reductions or temporary cessations of subduction have occurred in Earth's history. Such deviations in the continuity of plate tectonics have important consequences for Earth's thermal and continental evolution.

  6. Plate tectonics and planetary habitability: current status and future challenges.

    PubMed

    Korenaga, Jun

    2012-07-01

    Plate tectonics is one of the major factors affecting the potential habitability of a terrestrial planet. The physics of plate tectonics is, however, still far from being complete, leading to considerable uncertainty when discussing planetary habitability. Here, I summarize recent developments on the evolution of plate tectonics on Earth, which suggest a radically new view on Earth dynamics: convection in the mantle has been speeding up despite its secular cooling, and the operation of plate tectonics has been facilitated throughout Earth's history by the gradual subduction of water into an initially dry mantle. The role of plate tectonics in planetary habitability through its influence on atmospheric evolution is still difficult to quantify, and, to this end, it will be vital to better understand a coupled core-mantle-atmosphere system in the context of solar system evolution. PMID:22256796

  7. Plate tectonics and planetary habitability: current status and future challenges.

    PubMed

    Korenaga, Jun

    2012-07-01

    Plate tectonics is one of the major factors affecting the potential habitability of a terrestrial planet. The physics of plate tectonics is, however, still far from being complete, leading to considerable uncertainty when discussing planetary habitability. Here, I summarize recent developments on the evolution of plate tectonics on Earth, which suggest a radically new view on Earth dynamics: convection in the mantle has been speeding up despite its secular cooling, and the operation of plate tectonics has been facilitated throughout Earth's history by the gradual subduction of water into an initially dry mantle. The role of plate tectonics in planetary habitability through its influence on atmospheric evolution is still difficult to quantify, and, to this end, it will be vital to better understand a coupled core-mantle-atmosphere system in the context of solar system evolution.

  8. Material Characterization of Flexibly Supported Shear Deformable Laminated Composite Plates

    NASA Astrophysics Data System (ADS)

    Lee, C. R.; Kam, T. Y.

    2006-03-01

    This paper presents a method for nondestructively evaluating the system parameters of elastically restrained shear deformable laminated composite plates using measured natural frequencies. The proposed method is established on the basis of a multi-start global minimization method in which an objective function measuring the differences between the predicted and measured natural frequencies is constructed and a design variables normalization technique for expediting the convergence of the search of the solution is adopted. Vibration testing of several laminated composite plates with different boundary conditions was performed. Seven natural frequencies extracted from the vibration data of each of the plates were used in the proposed method to identify the system parameters of the plate. Excellent results have been obtained for the plates.

  9. BEPLATE emdash simulation of electrochemical plating

    SciTech Connect

    Giles, G.E. ); Gray, L.J. ); Bullock, J.S. IV )

    1990-09-01

    BEPLATE is a FORTRAN code that uses the boundary element method to simulate the electrochemical plating of material on parts, primarily rotating axisymmetric parts. A boundary element technique is used to solve for the local current density and thus the plating rate on the part, which is used to calculate the growth in the plated layer over a user-specified time step. The surface is moved to reflect this growth, and the new surface is used to generate the local current density. This cycle is repeated until the final time specified by the analyst, producing the final plated thickness. BEPLATE includes models for the polarization effects at both the part (cathode) and anode and allows the use of symmetry planes and nonconducting shields. For electroplating simulations, the part shape is normally assumed to be axisymmetric with a centerline along the z-axis. More general part shapes can be analyzed by BEPLATE if the surface growth simulation is not needed. In either case, the shield, anode, and tank geometries are not restricted to specific shapes. This report includes the information required to run BEPLATE, specifically, a brief description of the BEPLATE system including hardware and software requirements, a description of the complete simulation process, discussion of rules for generating models, and additional reference material. This system of codes consists of model generators (PIGS or PATRAN), input processor (BEPIN), the simulation code (BEPLATE) and postprocessing codes (PATRAN or CONPLOT).

  10. 10. DETAIL OF BUILDER'S PLATE AT NORTH PORTAL. PLATE READS: ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. DETAIL OF BUILDER'S PLATE AT NORTH PORTAL. PLATE READS: 1889, BUILT BY THE BERLIN IRON BRIDGE CO. EAST BERLIN CONN. DOUGLAS & JARVIS PAT. APT. 16, 1878, AP'L 17, 1885. A.P. FORESMAN, WM. S. STARR, T.J. STREBEIGH, COMMISSIONERS. - Pine Creek Bridge, River Road spanning Pine Creek, Jersey Shore, Lycoming County, PA

  11. Plate tectonics conserves angular momentum

    NASA Astrophysics Data System (ADS)

    Bowin, C.

    2010-03-01

    A new combined understanding of plate tectonics, Earth internal structure, and the role of impulse in deformation of the Earth's crust is presented. Plate accelerations and decelerations have been revealed by iterative filtering of the quaternion history for the Euler poles that define absolute plate motion history for the past 68 million years, and provide an unprecedented precision for plate angular rotation variations with time at 2-million year intervals. Stage poles represent the angular rotation of a plate's motion between adjacent Euler poles, and from which the maximum velocity vector for a plate can be determined. The consistent maximum velocity variations, in turn, yield consistent estimates of plate accelerations and decelerations. The fact that the Pacific plate was shown to accelerate and decelerate, implied that conservation of plate tectonic angular momentum must be globally conserved, and that is confirmed by the results shown here (total angular momentum ~1.4+27 kg m2 s-1). Accordingly, if a plate decelerates, other plates must increase their angular momentums to compensate. In addition, the azimuth of the maximum velocity vectors yields clues as to why the "bend" in the Emperor-Hawaiian seamount trend occurred near 46 Myr. This report summarizes processing results for 12 of the 14 major tectonic plates of the Earth (except for the Juan de Fuca and Philippine plates). Plate accelerations support the contention that plate tectonics is a product of torques that most likely are sustained by the sinking of positive density anomalies revealed by geoid anomalies of the degree 4-10 packet of the Earth's spherical harmonic coefficients. These linear positive geoid anomalies underlie plate subduction zones and are presumed due to phase changes in subducted gabbroic lithosphere at depth in the upper lower mantle (above 1200 km depth). The tectonic plates are pulled along by the sinking of these positive mass anomalies, rather than moving at near constant

  12. Are allogenic or xenogenic screws and plates a reasonable alternative to alloplastic material for osteosynthesis--a histomorphological analysis in a dynamic system.

    PubMed

    Jacobsen, C; Obwegeser, J A

    2010-12-01

    Despite invention of titanium and resorbable screws and plates, still, one of the main challenges in bone fixation is the search for an ideal osteosynthetic material. Biomechanical properties, biocompatibility, and also cost effectiveness and clinical practicability are factors for the selection of a particular material. A promising alternative seems to be screws and plates made of bone. Recently, xenogenic bone pins and screws have been invented for use in joint surgery. In this study, screws made of allogenic sheep and xenogenic human bone were analyzed in a vital and dynamic sheep-model and compared to conventional titanium screws over a standard period of bone healing of 56 days with a constant applied extrusion force. Biomechanical analysis and histomorphological evaluation were performed. After 56 days of insertion xenogenic screws made of human bone showed significantly larger distance of extrusion of on average 173.8 μm compared to allogenic screws made of sheep bone of on average 27.8 and 29.95 μm of the titanium control group. Severe resorption processes with connective tissue interposition were found in the histomorphological analysis of the xenogenic screws in contrast to new bone formation and centripetal vascularization of the allogenic bone screw, as well as in processes of incorporation of the titanium control group. The study showed allogenic cortical bone screws as a substantial alternative to titanium screws with good biomechanical properties. In contrast to other reports a different result was shown for the xenogenic bone screws. They showed insufficient holding strength with confirmative histomorphological signs of degradation and insufficient osseointegration. Before common clinical use of xenogenic osteosynthetic material, further evaluation should be performed. PMID:20813368

  13. From Neural Plate to Cortical Arousal—A Neuronal Network Theory of Sleep Derived from in Vitro “Model” Systems for Primordial Patterns of Spontaneous Bioelectric Activity in the Vertebrate Central Nervous System

    PubMed Central

    Corner, Michael A.

    2013-01-01

    In the early 1960s intrinsically generated widespread neuronal discharges were discovered to be the basis for the earliest motor behavior throughout the animal kingdom. The pattern generating system is in fact programmed into the developing nervous system, in a regionally specific manner, already at the early neural plate stage. Such rhythmically modulated phasic bursts were next discovered to be a general feature of developing neural networks and, largely on the basis of experimental interventions in cultured neural tissues, to contribute significantly to their morpho-physiological maturation. In particular, the level of spontaneous synchronized bursting is homeostatically regulated, and has the effect of constraining the development of excessive network excitability. After birth or hatching, this “slow-wave” activity pattern becomes sporadically suppressed in favor of sensory oriented “waking” behaviors better adapted to dealing with environmental contingencies. It nevertheless reappears periodically as “sleep” at several species-specific points in the diurnal/nocturnal cycle. Although this “default” behavior pattern evolves with development, its essential features are preserved throughout the life cycle, and are based upon a few simple mechanisms which can be both experimentally demonstrated and simulated by computer modeling. In contrast, a late onto- and phylogenetic aspect of sleep, viz., the intermittent “paradoxical” activation of the forebrain so as to mimic waking activity, is much less well understood as regards its contribution to brain development. Some recent findings dealing with this question by means of cholinergically induced “aroused” firing patterns in developing neocortical cell cultures, followed by quantitative electrophysiological assays of immediate and longterm sequelae, will be discussed in connection with their putative implications for sleep ontogeny. PMID:24961426

  14. Plate tectonics, damage and inheritance

    NASA Astrophysics Data System (ADS)

    Bercovici, David; Ricard, Yanick

    2014-04-01

    The initiation of plate tectonics on Earth is a critical event in our planet's history. The time lag between the first proto-subduction (about 4 billion years ago) and global tectonics (approximately 3 billion years ago) suggests that plates and plate boundaries became widespread over a period of 1 billion years. The reason for this time lag is unknown but fundamental to understanding the origin of plate tectonics. Here we suggest that when sufficient lithospheric damage (which promotes shear localization and long-lived weak zones) combines with transient mantle flow and migrating proto-subduction, it leads to the accumulation of weak plate boundaries and eventually to fully formed tectonic plates driven by subduction alone. We simulate this process using a grain evolution and damage mechanism with a composite rheology (which is compatible with field and laboratory observations of polycrystalline rocks), coupled to an idealized model of pressure-driven lithospheric flow in which a low-pressure zone is equivalent to the suction of convective downwellings. In the simplest case, for Earth-like conditions, a few successive rotations of the driving pressure field yield relic damaged weak zones that are inherited by the lithospheric flow to form a nearly perfect plate, with passive spreading and strike-slip margins that persist and localize further, even though flow is driven only by subduction. But for hotter surface conditions, such as those on Venus, accumulation and inheritance of damage is negligible; hence only subduction zones survive and plate tectonics does not spread, which corresponds to observations. After plates have developed, continued changes in driving forces, combined with inherited damage and weak zones, promote increased tectonic complexity, such as oblique subduction, strike-slip boundaries that are subparallel to plate motion, and spalling of minor plates.

  15. Plate tectonics, damage and inheritance.

    PubMed

    Bercovici, David; Ricard, Yanick

    2014-04-24

    The initiation of plate tectonics on Earth is a critical event in our planet's history. The time lag between the first proto-subduction (about 4 billion years ago) and global tectonics (approximately 3 billion years ago) suggests that plates and plate boundaries became widespread over a period of 1 billion years. The reason for this time lag is unknown but fundamental to understanding the origin of plate tectonics. Here we suggest that when sufficient lithospheric damage (which promotes shear localization and long-lived weak zones) combines with transient mantle flow and migrating proto-subduction, it leads to the accumulation of weak plate boundaries and eventually to fully formed tectonic plates driven by subduction alone. We simulate this process using a grain evolution and damage mechanism with a composite rheology (which is compatible with field and laboratory observations of polycrystalline rocks), coupled to an idealized model of pressure-driven lithospheric flow in which a low-pressure zone is equivalent to the suction of convective downwellings. In the simplest case, for Earth-like conditions, a few successive rotations of the driving pressure field yield relic damaged weak zones that are inherited by the lithospheric flow to form a nearly perfect plate, with passive spreading and strike-slip margins that persist and localize further, even though flow is driven only by subduction. But for hotter surface conditions, such as those on Venus, accumulation and inheritance of damage is negligible; hence only subduction zones survive and plate tectonics does not spread, which corresponds to observations. After plates have developed, continued changes in driving forces, combined with inherited damage and weak zones, promote increased tectonic complexity, such as oblique subduction, strike-slip boundaries that are subparallel to plate motion, and spalling of minor plates. PMID:24717430

  16. Plate tectonics, damage and inheritance.

    PubMed

    Bercovici, David; Ricard, Yanick

    2014-04-24

    The initiation of plate tectonics on Earth is a critical event in our planet's history. The time lag between the first proto-subduction (about 4 billion years ago) and global tectonics (approximately 3 billion years ago) suggests that plates and plate boundaries became widespread over a period of 1 billion years. The reason for this time lag is unknown but fundamental to understanding the origin of plate tectonics. Here we suggest that when sufficient lithospheric damage (which promotes shear localization and long-lived weak zones) combines with transient mantle flow and migrating proto-subduction, it leads to the accumulation of weak plate boundaries and eventually to fully formed tectonic plates driven by subduction alone. We simulate this process using a grain evolution and damage mechanism with a composite rheology (which is compatible with field and laboratory observations of polycrystalline rocks), coupled to an idealized model of pressure-driven lithospheric flow in which a low-pressure zone is equivalent to the suction of convective downwellings. In the simplest case, for Earth-like conditions, a few successive rotations of the driving pressure field yield relic damaged weak zones that are inherited by the lithospheric flow to form a nearly perfect plate, with passive spreading and strike-slip margins that persist and localize further, even though flow is driven only by subduction. But for hotter surface conditions, such as those on Venus, accumulation and inheritance of damage is negligible; hence only subduction zones survive and plate tectonics does not spread, which corresponds to observations. After plates have developed, continued changes in driving forces, combined with inherited damage and weak zones, promote increased tectonic complexity, such as oblique subduction, strike-slip boundaries that are subparallel to plate motion, and spalling of minor plates.

  17. Repulsive Casimir force in magnetodielectric plate configurations

    NASA Astrophysics Data System (ADS)

    Pappakrishnan, Venkatesh K.; Mundru, Pattabhiraju C.; Genov, Dentcho A.

    2014-01-01

    The Casimir force between purely dielectric materials is generally attractive and can lead to increased friction and stiction effects in nanoscale devices. While prospective quantum levitating systems have been proposed for high dielectric constant host materials, reversal of the Casimir force with air/vacuum as the intermediate medium remains challenging. Here, the problem of quantum levitation is studied for a system consisting of two parallel magnetodielectric plates. A simple analytical treatment of the problem is provided through the introduction of an upper bound of the force. An explicit sufficient condition for the manifestation of Casimir force repulsion is derived in terms of the plate's material parameters and temperature. The sufficient condition can serve as a useful tool in designing quantum levitating systems with air as the intermediate medium, which is the natural environment for practical microscopic devices.

  18. Flat-plate heat pipe

    NASA Technical Reports Server (NTRS)

    Marcus, B. D.; Fleischman, G. L. (Inventor)

    1977-01-01

    Flat plate (vapor chamber) heat pipes were made by enclosing metal wicking between two capillary grooved flat panels. These heat pipes provide a unique configuration and have good capacity and conductance capabilities in zero gravity. When these flat plate vapor chamber heat pipes are heated or cooled, the surfaces are essentially isothermal, varying only 3 to 5 C over the panel surface.

  19. Metals plated on fluorocarbon polymers

    NASA Technical Reports Server (NTRS)

    Ford, H.; Krasinsky, J. B.; Vango, S. P.

    1964-01-01

    Electroplating lead on fluorocarbon polymer parts is accomplished by etching the parts to be plated with sodium, followed by successive depositions of silver and lead from ultrasonically agitated plating solutions. Metals other than lead may be electroplated on the silvered parts.

  20. Aseptic laboratory techniques: plating methods.

    PubMed

    Sanders, Erin R

    2012-05-11

    Microorganisms are present on all inanimate surfaces creating ubiquitous sources of possible contamination in the laboratory. Experimental success relies on the ability of a scientist to sterilize work surfaces and equipment as well as prevent contact of sterile instruments and solutions with non-sterile surfaces. Here we present the steps for several plating methods routinely used in the laboratory to isolate, propagate, or enumerate microorganisms such as bacteria and phage. All five methods incorporate aseptic technique, or procedures that maintain the sterility of experimental materials. Procedures described include (1) streak-plating bacterial cultures to isolate single colonies, (2) pour-plating and (3) spread-plating to enumerate viable bacterial colonies, (4) soft agar overlays to isolate phage and enumerate plaques, and (5) replica-plating to transfer cells from one plate to another in an identical spatial pattern. These procedures can be performed at the laboratory bench, provided they involve non-pathogenic strains of microorganisms (Biosafety Level 1, BSL-1). If working with BSL-2 organisms, then these manipulations must take place in a biosafety cabinet. Consult the most current edition of the Biosafety in Microbiological and Biomedical Laboratories (BMBL) as well as Material Safety Data Sheets (MSDS) for Infectious Substances to determine the biohazard classification as well as the safety precautions and containment facilities required for the microorganism in question. Bacterial strains and phage stocks can be obtained from research investigators, companies, and collections maintained by particular organizations such as the American Type Culture Collection (ATCC). It is recommended that non-pathogenic strains be used when learning the various plating methods. By following the procedures described in this protocol, students should be able to: Perform plating procedures without contaminating media. Isolate single bacterial colonies by the streak-plating

  1. Aseptic Laboratory Techniques: Plating Methods

    PubMed Central

    Sanders, Erin R.

    2012-01-01

    Microorganisms are present on all inanimate surfaces creating ubiquitous sources of possible contamination in the laboratory. Experimental success relies on the ability of a scientist to sterilize work surfaces and equipment as well as prevent contact of sterile instruments and solutions with non-sterile surfaces. Here we present the steps for several plating methods routinely used in the laboratory to isolate, propagate, or enumerate microorganisms such as bacteria and phage. All five methods incorporate aseptic technique, or procedures that maintain the sterility of experimental materials. Procedures described include (1) streak-plating bacterial cultures to isolate single colonies, (2) pour-plating and (3) spread-plating to enumerate viable bacterial colonies, (4) soft agar overlays to isolate phage and enumerate plaques, and (5) replica-plating to transfer cells from one plate to another in an identical spatial pattern. These procedures can be performed at the laboratory bench, provided they involve non-pathogenic strains of microorganisms (Biosafety Level 1, BSL-1). If working with BSL-2 organisms, then these manipulations must take place in a biosafety cabinet. Consult the most current edition of the Biosafety in Microbiological and Biomedical Laboratories (BMBL) as well as Material Safety Data Sheets (MSDS) for Infectious Substances to determine the biohazard classification as well as the safety precautions and containment facilities required for the microorganism in question. Bacterial strains and phage stocks can be obtained from research investigators, companies, and collections maintained by particular organizations such as the American Type Culture Collection (ATCC). It is recommended that non-pathogenic strains be used when learning the various plating methods. By following the procedures described in this protocol, students should be able to: ● Perform plating procedures without contaminating media. ● Isolate single bacterial colonies by the

  2. The moving plate capacitor paradox

    NASA Astrophysics Data System (ADS)

    Davis, B. R.; Abbott, D.; Parrondo, J. M. R.

    2000-03-01

    For the first time we describe an apparent paradox concerning a moving plate capacitor driven by thermal noise from a resistor. A demon restores the plates of the capacitor to their original position, only when the voltage across the capacitor is small—hence only small forces are present for the demon to work against. The demon has to work harder than this to avoid the situation of perpetual motion, but the question is how? We explore the concept of a moving plate capacitor, driven by noise, a step further by examining the case where the restoring force on the capacitor plates is provided by a simple spring, rather than some unknown demon. We display simulation results with interesting behavior, particularly where the capacitor plates collide with each other.

  3. Present-day plate motions

    NASA Technical Reports Server (NTRS)

    Minster, J. B.; Jordan, T. H.

    1977-01-01

    A data set comprising 110 spreading rates, 78 transform fault azimuths and 142 earthquake slip vectors was inverted to yield a new instantaneous plate motion model, designated RM2. The mean averaging interval for the relative motion data was reduced to less than 3 My. A detailed comparison of RM2 with angular velocity vectors which best fit the data along individual plate boundaries indicates that RM2 performs close to optimally in most regions, with several notable exceptions. On the other hand, a previous estimate (RM1) failed to satisfy an extensive set of new data collected in the South Atlantic Ocean. It is shown that RM1 incorrectly predicts the plate kinematics in the South Atlantic because the presently available data are inconsistent with the plate geometry assumed in deriving RM1. It is demonstrated that this inconsistency can be remedied by postulating the existence of internal deformation with the Indian plate, although alternate explanations are possible.

  4. Plate tectonics, damage and inheritance

    NASA Astrophysics Data System (ADS)

    Bercovici, D. A.; Ricard, Y. R.

    2013-12-01

    The initiation of plate tectonics on Earth is a critical event in our planet's history. The time lag between the first proto subduction about 4Ga, evident in geochemical analysis from ancient cratons, to global tectonics by 3-2.7Ga, suggests that plates and plate boundaries spread globally over a 1Gyr period. We hypothesize that when sufficient lithospheric damage, which promotes shear-localization and long-lived weak zones, combines with transient mantle flow and migrating proto-subduction, it leads to the accumulation of plate boundaries and eventually fully formed tectonic plates driven by subduction alone. We demonstrate this process with an idealized model of pressure-driven flow (wherein a low pressure zone is equivalent to downwelling suction or slab pull) in a lithosphere that self-weakens according to a mylonitic-type polycrystalline grain-damage mechanism (Bercovici and Ricard, Phys. Earth Planet. Int. v.202-203, pp27-55, 2012). In the simplest case, for Earth-like conditions, four successive orthogonal rotations of the driving pressure field yield relic damage zones that are inherited to form a nearly perfect plate, with passive spreading and strike-slip margins that persist and localize further, even as flow is only driven by subduction. For Venus' hotter surface conditions, accumulation and inheritance of damage is negligible; hence only subduction zones survive and plate tectonics does not spread, which is compatible with observations. After plates are developed, continued changes in driving forces combined with inherited damage and weak zones, promote increased tectonic complexity, such as oblique subduction, strike-slip boundaries that are subparallel to plate motion, and spalling of minor and micro plates.

  5. Sub-Plate Overlap Code Documentation

    NASA Technical Reports Server (NTRS)

    Taff, L. G.; Bucciarelli, B.; Zarate, N.

    1997-01-01

    An expansion of the plate overlap method of astrometric data reduction to a single plate has been proposed and successfully tested. Each plate is (artificially) divided into sub-plates which can then be overlapped. This reduces the area of a 'plate' over which a plate model needs to accurately represent the relationship between measured coordinates and standard coordinates. Application is made to non-astrographic plates such as Schmidt plates and to wide-field astrographic plates. Indeed, the method is completely general and can be applied to any type of recording media.

  6. Optical Films Deposited By A Reactive Ion Plating Process

    NASA Astrophysics Data System (ADS)

    Pulker, H. K.; BUhler, M.; Hora, R.

    1986-12-01

    Oxide films on glass substrates, both single and multilayers, were produced by a special reactive ion plating process in the new automatic plating system BALZERS BAP 800. Structure, optical and mechanical film properties have been examined as a function of the deposition parameters. Multilayer systems consisting of TiO2 and Si02 films were deposited, and tests were made concerning optical characteristics, reproducibility and stability. Because of the unique characteristics of the films ion plating promises to become the new technology for the production of optical coatings.

  7. Saliva-based system for health and toxicology monitoring

    NASA Astrophysics Data System (ADS)

    Fenner, D. B.; Stevens, A. E.; Rosen, D. I.; Ferrante, A. A.; Davis, S. J.

    2009-05-01

    The practical utility of technologies for early detection of human exposure to a variety of toxic agents has been limited in many cases by the absence of instruments suitable for first responders and at field hospitals. Microarrays provide multiplexed assay of a large number of human biomarkers, including cytokines and chemokines, indicators of immune system health. Assay of saliva is less invasive and provides quick indication of exposure especially of the respiratory system. Our pilot clinical study has uncovered an early cytokine response in human saliva. As a model for respiratory exposure, a cohort of 16 adult volunteers was challenged with FluMistTM vaccinations, an FDA approved, attenuated live influenza virus. Blood and saliva cytokine levels were monitored immediately prior to and up to 7 days afterwards. Bead assay found little change in blood cytokine levels while several of those in saliva were frequently elevated above two standard deviations on trial days one and three. We have developed a prototype portable saliva monitoring system consisting of microarray cytokine capture plate, luminescent reporter, and whole plate imaging. Assay is with a commercial 96-well plate spotted with up to 16 distinct biomarkers per well and read by chemiluminescence. A battery-powered, 16-bit, cooled-CCD camera and laptop PC provide imaging and data reduction. Detection limits of common inflammatory cytokines were measured at about 1-5 pg/ml which is within the clinically significant range for saliva of exposed individuals, as verified for samples from the small clinical trial. An expanded study of cytokine response in saliva of therapeutic radiation oncology patients is being launched.

  8. A swirl flow evaporative cold plate

    NASA Technical Reports Server (NTRS)

    Niggemann, R. E.; Greenlee, W. J.; Hill, D. G.; Ellis, W.; Marshall, P.

    1985-01-01

    A forced flow evaporative cold plate is under development for future application to the thermal bus concept being pursued by NASA for Space Station Thermal Control. The vaporizer is a swirl-flow device employing a spiral tube coil geometry sandwiched between conductive metal plates upon which electric components could be mounted. This concept is based on the inherent phase separation that occurs in a two phase stream in curvilinear flow. This is a zero 'g' design with one 'g' all-attitude capability and is capable of high heat transfer coefficients, good isothermality, and the ability to function at heat fluxes approaching 5w/sq cm on the cold plates (10w/sq cm on the tube wall) with Freon 114. The advantages of this design over other two phase evaporator approaches are high heat flux capability, simplified control requirements, insensitivity to micro-gravity oscillations, and inexpensive manufacturability. The program included design, fabrication, and test of such a cold plate utilizing an existing test stand developed for two-phase thermal management system (TPTMS) testing. Test results analysis and conclusions are included.

  9. Elastocapillary coalescence of plates and pillars

    PubMed Central

    Wei, Z.; Schneider, T. M.; Kim, J.; Kim, H.-Y.; Aizenberg, J.; Mahadevan, L.

    2015-01-01

    When a fluid-immersed array of supported plates or pillars is dried, evaporation leads to the formation of menisci on the tips of the plates or pillars that bring them together to form complex patterns. Building on prior experimental observations, we use a combination of theory and computation to understand the nature of this instability and its evolution in both the two- and three-dimensional setting of the problem. For the case of plates, we explicitly derive the interaction torques based on the relevant physical parameters associated with pillar deformation, contact-line pinning/depinning and fluid volume changes. A Bloch-wave analysis for our periodic mechanical system captures the window of volumes where the two-plate eigenvalue characterizes the onset of the coalescence instability. We then study the evolution of these binary clusters and their eventual elastic arrest using numerical simulations that account for evaporative dynamics coupled to capillary coalescence. This explains both the formation of hierarchical clusters and the sensitive dependence of the final structures on initial perturbations, as seen in our experiments. We then generalize our analysis to treat the problem of pillar collapse in three dimensions, where the fluid domain is completely connected and the interface is a minimal surface with the uniform mean curvature. Our theory and simulations capture the salient features of experimental observations in a range of different situations and may thus be useful in controlling the ensuing patterns. PMID:25792949

  10. Fabrication procedures for HFIR control plates

    SciTech Connect

    Bowden, G.A.; Hicks, G.R.; Knight, R.W.

    1984-10-01

    The HFIR control system uses Alclad cylindrically shaped components, which have regions containing 31 vol % Eu/sub 2/O/sub 3/ and 38 vol % Ta, respectively. Exacting control of the water passage between these components and adjacent reactor parts is mandatory, and precise dimensional control of the finished products is required. This report describes the procedures developed for manufacturing outer control plates and inner control cylinders. Results are cited which demonstrate that circular-shaped outer control plates can be produced with less than 0.025-in. variation from the specified 9.300-in. radius in any region of the plate. Other results show that, by the exercise of careful control, inner control, inner control plates can be welded into cylindrical geometry with diametrical variations held to less than +- 0.010 in. of the intended 17.846-in. average diam. The cylinders can then be explosively sized, while under compression, with diametric variations of less than 0.005 in. while controlling roundness variations to less than 0.030 in. from the specified 17.842-in. finished diam.

  11. Application research of CO2 laser cutting natural stone plates

    NASA Astrophysics Data System (ADS)

    Ma, Lixiu; Song, Jijiang

    2009-08-01

    Now, the processing of natural stone plates is the high performance sawing machine primarily,many researchers deeply studied the processing characters in the sawing process and the strength characters during the processing. In order to realize the profiled-processing and pattern- carving of the natural stone, It lays a solid foundation for the laser cutting and the pattern-carving technology of natural stone plate. The working principle, type and characteristics of laser cutting are briefly described. The paper selects 6 kinds stone plates of natural taken as experimental sample,the experimental sample was China Shanxi Black, Old Spain Golden Yellow, New Spain Golden Yellow, Jazz White, Maple Leaf Red, Cream White respectively. Use high power CO2 laser cutting system,the stone plates cutting experiment of 6 kinds different hardness, the best working speed are obtained,The experimental results indicate that: The laser cutting speed has no correlation with the ingredient content of stone plate.

  12. Reaction-induced rheological weakening enables oceanic plate subduction

    NASA Astrophysics Data System (ADS)

    Hirauchi, Ken-Ichi; Fukushima, Kumi; Kido, Masanori; Muto, Jun; Okamoto, Atsushi

    2016-08-01

    Earth is the only terrestrial planet in our solar system where an oceanic plate subducts beneath an overriding plate. Although the initiation of plate subduction requires extremely weak boundaries between strong plates, the way in which oceanic mantle rheologically weakens remains unknown. Here we show that shear-enhanced hydration reactions contribute to the generation and maintenance of weak mantle shear zones at mid-lithospheric depths. High-pressure friction experiments on peridotite gouge reveal that in the presence of hydrothermal water, increasing strain and reactions lead to an order-of-magnitude reduction in strength. The rate of deformation is controlled by pressure-solution-accommodated frictional sliding on weak hydrous phyllosilicate (talc), providing a mechanism for the `cutoff' of the high peak strength at the brittle-plastic transition. Our findings suggest that infiltration of seawater into transform faults with long lengths and low slip rates is an important controlling factor on the initiation of plate tectonics on terrestrial planets.

  13. Reaction-induced rheological weakening enables oceanic plate subduction.

    PubMed

    Hirauchi, Ken-Ichi; Fukushima, Kumi; Kido, Masanori; Muto, Jun; Okamoto, Atsushi

    2016-08-26

    Earth is the only terrestrial planet in our solar system where an oceanic plate subducts beneath an overriding plate. Although the initiation of plate subduction requires extremely weak boundaries between strong plates, the way in which oceanic mantle rheologically weakens remains unknown. Here we show that shear-enhanced hydration reactions contribute to the generation and maintenance of weak mantle shear zones at mid-lithospheric depths. High-pressure friction experiments on peridotite gouge reveal that in the presence of hydrothermal water, increasing strain and reactions lead to an order-of-magnitude reduction in strength. The rate of deformation is controlled by pressure-solution-accommodated frictional sliding on weak hydrous phyllosilicate (talc), providing a mechanism for the 'cutoff' of the high peak strength at the brittle-plastic transition. Our findings suggest that infiltration of seawater into transform faults with long lengths and low slip rates is an important controlling factor on the initiation of plate tectonics on terrestrial planets.

  14. Locking compression plate distal ulna hook plate as alternative fixation for fifth metatarsal base fracture.

    PubMed

    Lee, Sang Ki; Park, Ju Sang; Choy, Won Sik

    2014-01-01

    Intramedullary screw fixation has been the most common treatment for fifth metatarsal base fractures. However, screw application will not achieve accurate reduction in fractures with small fragments, osteoporotic bone, or Lawrence zone 1 fractures. Because of the similar anatomic architecture between the distal ulna and the fifth metatarsal base, the purpose of the present study was to assess the results of a locking compression plate distal ulna hook plate in stabilizing displaced zone 1 or 2 fifth metatarsal base fractures. A total of 19 patients with Lawrence zone 1 (n = 12) or 2 (n = 7) fractures of the fifth metatarsal base were treated surgically with a locking compression plate distal ulna hook plate. The patients were evaluated clinically and radiographically, and the functional outcomes were graded using the American Orthopaedic Foot and Ankle Society midfoot scoring system. Radiographic bony union was obtained in all patients, at an average of 7.4 weeks. The mean American Orthopaedic Foot and Ankle Society midfoot score improved from 26 (range 0 to 45) points preoperatively to 94 (range 72 to 100) points at the final follow-up visit. Three patients developed post-traumatic cubometatarsal arthrosis, and 1 patient developed sural nerve neurapraxia. In our experience, the distal ulna hook plate achieved a high rate of bony consolidation and anatomically suitable fixation in zone 1 or 2 fifth metatarsal base fractures. We suggest that the locking compression plate distal ulna hook plate should be considered as an alternative treatment of multifragmentary, osteoporotic, and tuberosity avulsion (zone 1) fifth metatarsal base fractures.

  15. Mantle convection with plates and mobile, faulted plate margins.

    PubMed

    Zhong, S; Gurnis, M

    1995-02-10

    A finite-element formulation of faults has been incorporated into time-dependent models of mantle convection with realistic rheology, continents, and phase changes. Realistic tectonic plates naturally form with self-consistent coupling between plate and mantle dynamics. After the initiation of subduction, trenches rapidly roll back with subducted slabs temporarily laid out along the base of the transition zone. After the slabs have penetrated into the lower mantle, the velocity of trench migration decreases markedly. The inhibition of slab penetration into the lower mantle by the 670-kilometer phase change is greatly reduced in these models as compared to models without tectonic plates. PMID:17813909

  16. 49 CFR 229.85 - High voltage markings: doors, cover plates, or barriers.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false High voltage markings: doors, cover plates, or... Requirements Electrical System § 229.85 High voltage markings: doors, cover plates, or barriers. All doors, cover plates, or barriers providing direct access to high voltage equipment shall be marked...

  17. 49 CFR 229.85 - High voltage markings: doors, cover plates, or barriers.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false High voltage markings: doors, cover plates, or... Requirements Electrical System § 229.85 High voltage markings: doors, cover plates, or barriers. All doors, cover plates, or barriers providing direct access to high voltage equipment shall be marked...

  18. 49 CFR 229.85 - High voltage markings: doors, cover plates, or barriers.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false High voltage markings: doors, cover plates, or... Requirements Electrical System § 229.85 High voltage markings: doors, cover plates, or barriers. All doors, cover plates, or barriers providing direct access to high voltage equipment shall be marked...

  19. 3He Bilayer Film Adsorbed on Graphite Plated with a Bilayer of 4He: a New Frustrated 2D Magnetic System

    NASA Astrophysics Data System (ADS)

    Neumann, Michael; Nyéki, Ján; Cowan, Brian; Saunders, John

    2006-09-01

    The heat capacity and NMR response of a 3He bilayer adsorbed on graphite plated with a bilayer of 4He have been measured over the temperature range 1-80 mK. We find that the first 3He layer requires the presence of a 3He fluid overlayer before it solidifies. Solidification is completed at a total coverage close to 9.85 nm-2, On further increasing the coverage the heat capacity maximum grows from `antiferromagnetic-like' (AFM-like) to `ferromagnetic-like' (FM-like). On the other hand, when the 3He layer first solidifies, it has a low temperature saturation magnetisation corresponding to a significant fraction of full polarisation, and this increases with increasing coverage. Furthermore the effective exchange constant inferred from the high temperature magnetisation data is always ferromagnetic. The effective exchange constants inferred from the heat capacity and magnetisation are significantly larger than those observed in the second layer of pure 3He films adsorbed on bare graphite. Otherwise there are strong similarities in the coverage dependence of the heat capacity and magnetisation, providing fresh insights into how the magnetic ground state of such 2D magnets evolves as the frustration is tuned with increasing coverage.

  20. Vacuum fusion bonded glass plates having microstructures thereon

    DOEpatents

    Swierkowski, Steve P.; Davidson, James C.; Balch, Joseph W.

    2001-01-01

    An improved apparatus and method for vacuum fusion bonding of large, patterned glass plates. One or both glass plates are patterned with etched features such as microstructure capillaries and a vacuum pumpout moat, with one plate having at least one hole therethrough for communication with a vacuum pumpout fixture. High accuracy alignment of the plates is accomplished by a temporary clamping fixture until the start of the fusion bonding heat cycle. A complete, void-free fusion bond of seamless, full-strength quality is obtained through the plates; because the glass is heated well into its softening point and because of a large, distributed force that is developed that presses the two plates together from the difference in pressure between the furnace ambient (high pressure) and the channeling and microstructures in the plates (low pressure) due to the vacuum drawn. The apparatus and method may be used to fabricate microcapillary arrays for chemical electrophoresis; for example, any apparatus using a network of microfluidic channels embedded between plates of glass or similar moderate melting point substrates with a gradual softening point curve, or for assembly of glass-based substrates onto larger substrates, such as in flat panel display systems.

  1. Ultrasonic Testing of NIF Amplifier FAU Top Plates

    SciTech Connect

    Chinn, D J; Huber, R D; Haskins, J J; Rodriguez, J A; Souza, P R; Le, T V

    2002-05-07

    A key component in the National Ignition Facility (NIF) laser optic system is the amplifier frame assembly unit (FAU). The cast aluminum top plate that supports the FAU is required to withstand loads that would occur during an earthquake with a recurrence period of 1000 years. The stringent seismic requirements placed on the FAU top plate induced a study of the cast aluminum material used in the top plate. Ultrasonic testing was used to aid in characterizing the aluminum material used in the plates. This report documents the work performed using contact ultrasonic testing to characterize the FAU top plate material. The ultrasonic work reported here had 3 objectives: (1) inspect the plate material before cyclic testing conducted at the Pacific Earthquake Engineering Research Center (PEER); (2) determine the overall quality of individual plates; and (3) detect large defects in critical areas of individual plates. Section III, ''Pre-cyclic test inspection'', describes work performed in support of Objective 1. Section IV, ''Ultrasonic field measurements'', describes work performed in support of Objectives 2 and 3.

  2. Droplet formation under the effect of a flexible nozzle plate.

    PubMed

    Sangplung, S; Liburdy, J A

    2009-09-01

    Droplet formation from a flexible nozzle plate driven by a prescribed-waveform excitation of a piezoelectric is numerically investigated using a computational fluid dynamics (CFD) model with the volume of fluid (VOF) method. The droplet generator with a flexible nozzle plate, which is free to vibrate due to the pressure acting on the plate, is modeled in a CFD computational domain. The CFD analysis includes the fluid-structure interaction between fluid and a flexible plate using large deflection theory. The problem is characterized by the nondimensional variables based on the capillary parameters of time, velocity, and pressure. The CFD model is validated with the experiment results. This study examines the characteristics of the applied waveforms and nozzle plate material properties to change the vibrational characteristics of the nozzle plate. The effect of fluid properties on the droplet formation process is also investigated focusing on surface tension and viscous forces. Increasing the impulse of the piezoelectric can be used to cause a higher droplet velocity and it is shown that the vibration of the nozzle plate has a strong effect on the droplet velocity, shape, and volume. Surface tension has a strong influence on the droplet formation characteristics in contrast to viscous forces. For the combination of a fluid with high surface tension and the most flexible nozzle plate, this system cannot cause the droplet ejected out of the nozzle.

  3. Disturbed film flow on a vertical plate

    NASA Astrophysics Data System (ADS)

    Kheshgi, Haroon S.; Scriven, L. E.

    1987-04-01

    Flow of incompressible Newtonian liquid films is governed by the Navier-Stokes system with shear-free, balanced-normal-stress, and kinematic boundary conditions at the free surface. This system is solved here for the evolution of finite-amplitude two-dimensional disturbances to otherwise steady flow down a vertical plate by means of a finite element method adapted for free boundary problems. When flow is specified to be spatially periodic, fully developed steady flows that ensue approach time-periodic states, i.e., waves, the finite amplitude of which depends upon their wavelength. The family of time-periodic states connects to the steady, fully developed flow at a Hopf bifurcation that lies at a critical disturbance length, in agreement with the Orr-Sommerfeld analysis. Initial disturbances to flow down a plate of finite length grow as they propagate downward. In all cases studied here, however, steady flow is eventually approached.

  4. Vibration characteristics of rectangular plate in compressible inviscid fluid

    NASA Astrophysics Data System (ADS)

    Liao, Chan-Yi; Ma, Chien-Ching

    2016-02-01

    This paper presents a mathematical derivation of the vibration characteristics of an elastic thin plate placed at the bottom of a three dimensional rectangular container filled with compressible inviscid fluid. A set of beam functions is used as the admissible functions of the plate in a fluid-plate system, and the motion of the fluid induced by the deformation of the plate is obtained from a three-dimensional acoustic equation. Pressure from the fluid over the fluid-plate interface is integrated to form a virtual mass matrix. The frequency equation of the fluid-plate system is derived by combining mass, stiffness, and the virtual mass matrix. Solving the frequency equation makes it possible to obtain the dynamic characteristic of the fluid-plate system, such as resonant frequencies, corresponding mode shapes, and velocity of the fluid. Numerical calculations were performed for plates coupled with fluids with various degrees of compressibility to illustrate the difference between compressible and incompressible fluids in a fluid-plate system. The proposed method could be used to predict resonant frequencies and mode shapes with accuracy compared to that of incompressible fluid theory (IFT). The proposed method can be used to analyze cases involving high value of sound velocity, such as incompressible fluids. When the sound velocity approaches infinity, the results obtained for compressible fluids are similar to those of incompressible fluids. We also examined the influence of fluid compressibility on vibration characteristics in which a decrease in sound velocity was shown to correspond to a decrease in resonant frequency. Additional modes, not observed in incompressible fluids, were obtained in cases of low sound velocity, particularly at higher resonant frequencies. Fluid velocity plots clearly reveal that the additional resonant modes can be attributed to the compressible behavior of the fluid.

  5. Difficulties encountered removing locked plates

    PubMed Central

    Raja, S; Imbuldeniya, AM; S, Garg; Groom, G

    2012-01-01

    INTRODUCTION Locked plates are commonly used to obtain fixation in periarticular and comminuted fractures. Their use has also gained popularity in repairing fractures in osteoporotic bone. These plates provide stable fixation and promote biological healing. Over the last 3 years, we have used over 150 locked plates with varying success to fix periarticular fractures involving mainly the knee and ankle. In this study, we report our clinical experience and the difficulties encountered when removing locked plates in adult patients with a variety of indications including implant failure, infection, non-union and a palpable symptomatic implant. METHODS A retrospective analysis was performed of patients enrolled prospectively into a database. Included in the study were 36 consecutive adult patients who each underwent the procedure of locked plate removal in a single inner city level 1 trauma centre. Data collected included primary indication for fixation, indication for implant removal, time of the implant in situ, grade of operating surgeon and difficulties encountered during the procedure. RESULTS Implant removal was associated with a complication rate of 47%. The major problems encountered were difficulty in removing the locked screws and the implant itself. A total of ten cold welded screws were found in eight cases. Removal was facilitated by high speed metal cutting burrs and screw removal sets in all but one case, where a decision was made to leave the plate in situ. CONCLUSIONS The majority of studies investigating implant removal and problems encountered in doing so report a relatively high complication rate. With the advent of locking plates and their growing popularity, difficulties are now being seen intra-operatively when removing them. There is a paucity of data, however, specifically directed at locking plate removal. We recommend that surgeons should be aware of the potential complications while removing locked plates. Fluoroscopic control and all

  6. High loading uranium fuel plate

    DOEpatents

    Wiencek, Thomas C.; Domagala, Robert F.; Thresh, Henry R.

    1990-01-01

    Two embodiments of a high uranium fuel plate are disclosed which contain a meat comprising structured uranium compound confined between a pair of diffusion bonded ductile metal cladding plates uniformly covering the meat, the meat having a uniform high fuel loading comprising a content of uranium compound greater than about 45 Vol. % at a porosity not greater than about 10 Vol. %. In a first embodiment, the meat is a plurality of parallel wires of uranium compound. In a second embodiment, the meat is a dispersion compact containing uranium compound. The fuel plates are fabricated by a hot isostatic pressing process.

  7. High-sensitive and high-efficient biochemical analysis method using a bionic electronic eye in combination with a smartphone-based colorimetric reader system.

    PubMed

    Kaiqi Su; Quchao Zou; Ning Hu; Ping Wang

    2015-01-01

    Bionic electronic eye (Bionic e-Eye), a developed smartphone-based colorimetric reader system, consists of smartphone or pad (iPhone 4s or iPad 3) as detection instrument and portable accessory as illumination provider, integrating with a wide-angle lens, a piece of lowest-power electro luminescent and a custom-made dark hood. A 96-well microtiter plate (MTP) was positioned on the electro luminescent and Bionic e-Eye captures the detection images by the back camera of smartphone. Being similar to human visual system, the hue, saturation and value (HSV, also called hex cone model) color model was employed in image processing algorithm of Bionic e-Eye. Optimized system dimension was determined by the system steadiness experiment of different photograph distances. Moreover, the commercially available BCA protein assay and CCK8 cell number assay were carried out to evaluate this Bionic e-Eye. Analytical performance of Bionic e-Eye had the better precision, higher sensitivity than microtiter plate reader (MTPR) and previous smartphone-based colorimetric reader for both two assays. Also, Bionic e-Eye using optical image detection had simultaneous and synchronous working mode, while MPTR using machine moving detection had asynchronous working mode in high throughput detection. Therefore, Bionic e-Eye will be an ideal point-of-care (POC) colorimetric detection device in the field of clinical application, industrial quality control, environment monitoring, and food assessment.

  8. High-sensitive and high-efficient biochemical analysis method using a bionic electronic eye in combination with a smartphone-based colorimetric reader system.

    PubMed

    Kaiqi Su; Quchao Zou; Ning Hu; Ping Wang

    2015-01-01

    Bionic electronic eye (Bionic e-Eye), a developed smartphone-based colorimetric reader system, consists of smartphone or pad (iPhone 4s or iPad 3) as detection instrument and portable accessory as illumination provider, integrating with a wide-angle lens, a piece of lowest-power electro luminescent and a custom-made dark hood. A 96-well microtiter plate (MTP) was positioned on the electro luminescent and Bionic e-Eye captures the detection images by the back camera of smartphone. Being similar to human visual system, the hue, saturation and value (HSV, also called hex cone model) color model was employed in image processing algorithm of Bionic e-Eye. Optimized system dimension was determined by the system steadiness experiment of different photograph distances. Moreover, the commercially available BCA protein assay and CCK8 cell number assay were carried out to evaluate this Bionic e-Eye. Analytical performance of Bionic e-Eye had the better precision, higher sensitivity than microtiter plate reader (MTPR) and previous smartphone-based colorimetric reader for both two assays. Also, Bionic e-Eye using optical image detection had simultaneous and synchronous working mode, while MPTR using machine moving detection had asynchronous working mode in high throughput detection. Therefore, Bionic e-Eye will be an ideal point-of-care (POC) colorimetric detection device in the field of clinical application, industrial quality control, environment monitoring, and food assessment. PMID:26738081

  9. Characterizing Detonator Output Using Dynamic Witness Plates

    NASA Astrophysics Data System (ADS)

    Murphy, Michael; Adrian, Ronald

    2009-06-01

    A sub-microsecond, time-resolved micro-particle-image velocimetry (PIV) system is developed to investigate the output of explosive detonators. Detonator output is directed into a transparent solid that serves as a dynamic witness plate and instantaneous shock and material velocities are measured in a two-dimensional plane cutting through the shock wave as it propagates through the solid. For the case of unloaded initiators (e.g. exploding bridge wires, exploding foil initiators, etc.) the witness plate serves as a surrogate for the explosive material that would normally be detonated. The velocity-field measurements quantify the velocity of the shocked material and visualize the geometry of the shocked region. Furthermore, the time-evolution of the velocity-field can be measured at intervals as small as 10 ns using the PIV system. Current experimental results of unloaded exploding bridge wire output in polydimethylsiloxane (PDMS) witness plates demonstrate 20 MHz velocity-field sampling just 300 ns after initiation of the wire. Successful application of the PIV system to full-up explosive detonator output is also demonstrated.

  10. Carbon-assisted flyer plates

    DOEpatents

    Stahl, D.B.; Paisley, D.L.

    1994-04-12

    A laser driven flyer plate is described utilizing an optical fiber connected to a laser. The end of the optical fiber has a layer of carbon and a metal layer deposited onto it. The carbon layer provides the laser induced plasma which is superior to the plasma produced from most metals. The carbon layer plasma is capable of providing a flatter flyer plate, converting more of the laser energy to driving plasma, promoting a higher flyer plate acceleration, and providing a more uniform pulse behind the plate. In another embodiment, the laser is in optical communication with a substrate onto which a layer of carbon and a layer of metal have been deposited. 2 figures.

  11. The multigap resistive plate chamber

    SciTech Connect

    Zeballos, E. Cerron; Crotty, I.; Hatzifotiadou, D.; Valverde, J. Lamas; Neupane, S.; Williams, M. C. S.; Zichichi, A.

    2015-02-03

    The paper describes the multigap resistive plate chamber (RPC). This is a variant of the wide gap RPC. However it has much improved time resolution, while keeping all the other advantages of the wide gap RPC design.

  12. Tectonics: Changing of the plates

    NASA Astrophysics Data System (ADS)

    Brandon, Alan

    2016-10-01

    The composition of Earth's crust depends on the style of plate tectonics and of the melting regimes in the mantle. Analyses of the oldest identified rocks suggest that these styles and the resulting crust have changed over Earth's history.

  13. Quaternions as astrometric plate constants

    NASA Technical Reports Server (NTRS)

    Jefferys, William H.

    1987-01-01

    A new method for solving problems in relative astrometry is proposed. In it, the relationship between the measured quantities and the components of the position vector of a star is modeled using quaternions, in effect replacing the plate constants of a standard four-plate-constant solution with the four components of a quaternion. The method allows a direct solution for the position vectors of the stars, and hence for the equatorial coordinates. Distortions, magnitude, and color effects are readily incorporated into the formalism, and the method is directly applicable to overlapping-plate problems. The advantages of the method include the simplicity of the resulting equations, their freedom from singularities, and the fact that trigonometric functions and tangential point transformations are not needed to model the plate material. A global solution over the entire sky is possible.

  14. 3D high throughput screening and profiling of embryoid bodies in thermoformed microwell plates.

    PubMed

    Vrij, E J; Espinoza, S; Heilig, M; Kolew, A; Schneider, M; van Blitterswijk, C A; Truckenmüller, R K; Rivron, N C

    2016-02-21

    3D organoids using stem cells to study development and disease are now widespread. These models are powerful to mimic in vivo situations but are currently associated with high variability and low throughput. For biomedical research, platforms are thus necessary to increase reproducibility and allow high-throughput screens (HTS). Here, we introduce a microwell platform, integrated in standard culture plates, for functional HTS. Using micro-thermoforming, we form round-bottom microwell arrays from optically clear cyclic olefin polymer films, and assemble them with bottom-less 96-well plates. We show that embryonic stem cells aggregate faster and more reproducibly (centricity, circularity) as compared to a state-of-the-art microwell array. We then run a screen of a chemical library to direct differentiation into primitive endoderm (PrE) and, using on-chip high content imaging (HCI), we identify molecules, including regulators of the cAMP pathway, regulating tissue size, morphology and PrE gene activity. We propose that this platform will benefit to the systematic study of organogenesis in vitro. PMID:26775648

  15. Surface-activated microtiter-plate microarray for simultaneous CRP quantification and viral antibody detection.

    PubMed

    Viitala, Sari M; Jääskeläinen, Anne J; Kelo, Eira; Sirola, Helena; Moilanen, Kirsi; Suni, Jukka; Vaheri, Antti; Vapalahti, Olli; Närvänen, Ale

    2013-02-01

    Microarrays are widely used in high-throughput DNA and RNA hybridization tests and recently adopted to protein and small molecule interaction studies in basic research and diagnostics. Parallel detection of serum antibodies and antigens has several potential applications in epidemiologic research, vaccine development, and in the diagnosis of allergies, autoimmunity, and infectious diseases. This study demonstrates an immobilization method for immunoassay-based microarray in conventional 96-well polystyrene plates for a serologic diagnostic method combined with quantitative C-reactive protein (CRP) assay. A synthetic peptide (HIV-1), a recombinant protein (Puumala hantavirus nucleocapsid), and purified virus preparations (Sindbis and adenoviruses) were used as antigens for virus-specific antibody detection and monoclonal anti-CRP antibody for antigen detection. The microarray was based on conventional enzyme immunoassays and densitometry from photographed results. Peptide and recombinant antigens functioned well, while whole virus antigens gave discrepant results in 1 out of 23 samples from the reference method, tested with human sera with various antibody responses. The CRP results were in concordance in the concentration range 0.5-150 mg/L with 2 commercially available CRP assays: ReaScan rapid test (R(2) = 0.9975) and Cobas 6000 analyzer (R(2) =0.9595). The results indicate that microtiter plates provide a promising platform for further development of microarrays for parallel antibody and antigen detection. PMID:23219230

  16. 3D high throughput screening and profiling of embryoid bodies in thermoformed microwell plates.

    PubMed

    Vrij, E J; Espinoza, S; Heilig, M; Kolew, A; Schneider, M; van Blitterswijk, C A; Truckenmüller, R K; Rivron, N C

    2016-02-21

    3D organoids using stem cells to study development and disease are now widespread. These models are powerful to mimic in vivo situations but are currently associated with high variability and low throughput. For biomedical research, platforms are thus necessary to increase reproducibility and allow high-throughput screens (HTS). Here, we introduce a microwell platform, integrated in standard culture plates, for functional HTS. Using micro-thermoforming, we form round-bottom microwell arrays from optically clear cyclic olefin polymer films, and assemble them with bottom-less 96-well plates. We show that embryonic stem cells aggregate faster and more reproducibly (centricity, circularity) as compared to a state-of-the-art microwell array. We then run a screen of a chemical library to direct differentiation into primitive endoderm (PrE) and, using on-chip high content imaging (HCI), we identify molecules, including regulators of the cAMP pathway, regulating tissue size, morphology and PrE gene activity. We propose that this platform will benefit to the systematic study of organogenesis in vitro.

  17. Spirit's Tracks around 'Home Plate'

    NASA Technical Reports Server (NTRS)

    2006-01-01

    [figure removed for brevity, see original site] Annotated Version

    This portion of an image acquired by the Mars Reconnaissance Orbiter's High Resolution Imaging Science Experiment camera shows the Spirit rover's winter campaign site. The rover is visible. So is the 'Low Ridge' feature where Spirit was parked with an 11-degree northerly tilt to maximize sunlight on the solar panels during the southern winter season. Tracks made by Spirit on the way to 'Home Plate' and to and from 'Tyrone,' an area of light-toned soils exposed by rover wheel motions, are also evident. The original image is catalogued as PSP_001513_1655_red and was taken Sept. 29, 2006.

    NASA's Jet Propulsion Laboratory, a division of the California Institute of Technology in Pasadena, manages the Mars Reconnaissance Orbiter for NASA's Science Mission Directorate, Washington. Lockheed Martin Space Systems, Denver, is the prime contractor for the project and built the spacecraft. The High Resolution Imaging Science Experiment is operated by the University of Arizona, Tucson, and the instrument was built by Ball Aerospace and Technology Corp., Boulder, Colo.

  18. Seismicity of the Earth 1900–2010 Australia plate and vicinity

    USGS Publications Warehouse

    Benz, Harley M.; Herman, Matthew; Tarr, Arthur C.; Hayes, Gavin P.; Furlong, Kevin P.; Villaseñor, Antonio; Dart, Richard L.; Rhea, Susan

    2011-01-01

    This map shows details of the Australia plate and vicinity not presented in Tarr and others (2010). The boundary of the Australia plate includes all fundamental plate boundary components: mid-ocean ridges, subduction zones, arc-continent collisions, and large-offset transform faults. Along the southern edge of the plate the mid-ocean ridge separates the Australia and Antarctica plates and its behavior is straightforward. In contrast, the other boundary segments that ring the Australia plate represent some of the most seismically active elements of the global plate boundary system, and some of the most rapidly evolving plate interactions. As a result, there are some very complex structures which host many large and great earthquakes

  19. Pulse plating of nickel deposits

    SciTech Connect

    Stimetz, C.J.; Stevenson, M.F.

    1980-02-01

    Pulse plated and conventional nickel deposits have been compared for differences in morphology, mechanical properties, and microstructure. The deposits were obtained from nickel sulfamate, nickel chloride, and Watts nickel plating solutions. No significant differences were found in the direct and pulse current deposits from the sulfamate and chloride solutions; however, significant differences in microstructure, yield strength, and microhardness were observed in deposits from the Watts nickel solution.

  20. Titer-plate formatted continuous flow thermal reactors: Design and performance of a nanoliter reactor.

    PubMed

    Chen, Pin-Chuan; Park, Daniel S; You, Byoung-Hee; Kim, Namwon; Park, Taehyun; Soper, Steven A; Nikitopoulos, Dimitris E; Murphy, Michael C

    2010-08-01

    velocity, fragment length, and copy number. A 99 bp DNA fragment was successfully amplified at flow velocities from 1 mm/s to 3 mm/s, requiring from 8.16 minutes for 20 cycles (24.48 s/cycle) to 2.72 minutes for 20 cycles (8.16 s/cycle), respectively. Yield compared to the same amplification sequence performed using a bench top thermal cycler decreased nonlinearly from 73% (at 1 mm/s) to 13% (at 3 mm/s) with shorter residence time at the optimal temperatures for the reactions due to increased flow rate primarily responsible. Six different DNA fragments with lengths between 99 bp and 997 bp were successfully amplified at 1 mm/s. Repeatable, successful amplification of a 99 bp fragment was achieved with a minimum of 8000 copies of the DNA template. This is the first demonstration and characterization of continuous flow thermal reactors within the 8 mm × 8 mm footprint of a 96-well micro-titer plate and is the smallest continuous flow PCR to date.

  1. Titer-plate formatted continuous flow thermal reactors: Design and performance of a nanoliter reactor

    PubMed Central

    Chen, Pin-Chuan; Park, Daniel S.; You, Byoung-Hee; Kim, Namwon; Park, Taehyun; Soper, Steven A.; Nikitopoulos, Dimitris E.; Murphy, Michael C.

    2010-01-01

    velocity, fragment length, and copy number. A 99 bp DNA fragment was successfully amplified at flow velocities from 1 mm/s to 3 mm/s, requiring from 8.16 minutes for 20 cycles (24.48 s/cycle) to 2.72 minutes for 20 cycles (8.16 s/cycle), respectively. Yield compared to the same amplification sequence performed using a bench top thermal cycler decreased nonlinearly from 73% (at 1 mm/s) to 13% (at 3 mm/s) with shorter residence time at the optimal temperatures for the reactions due to increased flow rate primarily responsible. Six different DNA fragments with lengths between 99 bp and 997 bp were successfully amplified at 1 mm/s. Repeatable, successful amplification of a 99 bp fragment was achieved with a minimum of 8000 copies of the DNA template. This is the first demonstration and characterization of continuous flow thermal reactors within the 8 mm × 8 mm footprint of a 96-well micro-titer plate and is the smallest continuous flow PCR to date. PMID:20871807

  2. Thickness Evaluation of Aluminium Plate Using Pulsed Eddy Current Technique

    NASA Astrophysics Data System (ADS)

    Singh, Gurpartap; Bapat, Harsh Madhukar; Singh, Bhanu Pratap; Bandyopadhyay, Manojit; Puri, Rakesh Kumar; Badodkar, Deepak Narayanrao

    2013-10-01

    This paper describes a pulsed eddy current (PEC) based non-destructive testing system used for detection of thickness variation in aluminium plate. A giant magneto-resistive sensor has been used instead of pick up coil for detecting resultant magnetic field. The PEC response signals obtained from 1 to 5 mm thickness change in aluminium plate were investigated. Two time domain features, namely peak value and time to peak, of PEC response were used for extracting information about thickness variation in aluminium plate. The variation of peak value and time to peak with thickness was compared. A program was developed to display the thickness variation of the tested sample.

  3. X-/Ka-band dichroic plate noise temperature reduction

    NASA Technical Reports Server (NTRS)

    Veruttipong, W.; Lee, P.

    1994-01-01

    The X-/Ka-band (8.4 GHz/32.0 GHz) dichroic plate installed as DSS 13 contributes an estimated 3 K to the system noise temperature at 32.0 GHz. Approximately 1 percent of the Ka-band incident field is reflected by the plate into the 300-K environment of the DSS-13 pedestal room. A low-cost, easily implemented method of reducing the noise temperature is presented. Using a curved reflector, the reflected field can be re-focused into an 80-K cold load, reducing the noise temperature contribution of the dichroic plate by about 2 K.

  4. Plate tectonics and the Gulf of California region

    SciTech Connect

    Schmidt, N.

    1990-11-01

    The geology and tectonism of California have been influenced greatly by the collision and interaction between the Pacific plate and the North American plate. The forces generated by this interaction caused substantial horizontal movement along the San Andreas fault system and created the Gulf of California rift zone. This article summarizes the unique features of the gulf, describes the theory of plate tectonics, explains how tectonism may have affected the geologic evolution and physiography of the gulf, and illustrates the process by which the Colorado River became linked to the gulf.

  5. Impact on multilayered composite plates

    NASA Technical Reports Server (NTRS)

    Kim, B. S.; Moon, F. C.

    1977-01-01

    Stress wave propagation in a multilayer composite plate due to impact was examined by means of the anisotropic elasticity theory. The plate was modelled as a number of identical anisotropic layers and the approximate plate theory of Mindlin was then applied to each layer to obtain a set of difference-differential equations of motion. Dispersion relations for harmonic waves and correction factors were found. The governing equations were reduced to difference equations via integral transforms. With given impact boundary conditions these equations were solved for an arbitrary number of layers in the plate and the transient propagation of waves was calculated by means of a Fast Fourier Transform algorithm. The multilayered plate problem was extended to examine the effect of damping layers present between two elastic layers. A reduction of the interlaminar normal stress was significant when the thickness of damping layer was increased but the effect was mostly due to the softness of the damping layer. Finally, the problem of a composite plate with a crack on the interlaminar boundary was formulated.

  6. The T-tubular network and its triads in the sole plate sarcoplasm of the motor end-plate of mammals.

    PubMed

    Dauber, W; Voigt, T; Härtel, X; Mayer, J

    2000-01-01

    The transition between the subsynaptic folds and the T-tubules demonstrated in a former paper was further investigated in the sole plate area by using the extracellular marker Lanthanum. A tubular network of the T-system of the sole plate area which is connected to the subsynaptic folds and to the t-tubular elements between the myofibrils is described for the first time. T-tubules of this network criss-cross through the sarcoplasm of the sole plate and lie in close proximity to sole plate nuclei and mitochondria. Cisterns of sarcoplasmic reticulum of the sole plate area make contact with these t-tubules forming triads. The possible physiological role of this sole plate network and its triads will be discussed with regard to a transport of substances in tubules with the dimension of nanotubes and Ca2+ activated processes in the sole plate area.

  7. Marginal deformation of crustal plates as key to crustal motion, crustal spirals, and the driving force

    SciTech Connect

    Wood, B.G.M.

    1986-07-01

    Present plate tectonic models concentrate on compressive- and extensive-type plate margins, often incorporating shear margins as a subtype of compressive margins. However, if a single moving plate is considered, it becomes apparent that the leading edge is a compressive margin, the trailing edge is an extensive margin, and the lateral edges are shear margins. Conversely, if a plate's margin can be recognized by identifying areas of subduction (compression), rifting (extension), and strike slip and buckle folding (shearing), then not only can a plate be identified but its motion can also be inferred. The Pacific plate provides an excellent example. It is bounded by subduction trenches along its west-northwest margin, extension rifts along its east-southeast margin, and shear and buckle-fold complexes along its south-southwest and north-northeast margins. A west-northwest motion is inferred. As other major plates are examined, two striking features are revealed. A west-northwest to northwest motion is consistently identified, and the plates line up end to end forming a northwest-spiraling segmented band encircling the globe. The lateral margins of this band form the well-known Tethyan shear system. The plates comprising this band are of varying sizes and composition, and the extent of deformation along a plate margin is directly related to plate size. The Pacific and Eurasian plates dominate in size and marginal deformation. The tail of this north-spiraling ribbon of crustal plates is deformed in the Southern Hemisphere, most notably in the area of the African, Indian, and Australian plates. Each southern plate has a strong north component of motion as well as a counterclockwise spiraling action. The plates appear to have rotated in response to drag along the southern margin of the Pacific and Eurasian plates.

  8. Flat-plate solar array project: Experimental process system development unit for producing semiconductor-grade silicon using the silane-to-silicon process

    NASA Technical Reports Server (NTRS)

    1981-01-01

    The engineering design, fabrication, assembly, operation, economic analysis, and process support research and development for an Experimental Process System Development Unit for producing semiconductor-grade silicon using the slane-to-silicon process are reported. The design activity was completed. About 95% of purchased equipment was received. The draft of the operations manual was about 50% complete and the design of the free-space system continued. The system using silicon power transfer, melting, and shotting on a psuedocontinuous basis was demonstrated.

  9. Flat-plate solar-array project. Experimental process system development unit for producing semiconductor-grade silicon using the silane-to-silicon process

    NASA Technical Reports Server (NTRS)

    1981-01-01

    The engineering design, fabrication, assembly, operation, economic analysis, and process support R and D for an Experimental Process System Development Unit (EPSDU) are reported. About 95% of purchased equipment is received and will be reshipped to the West Coast location. The Data Collection System is completed. In the area of melting/consolidation, to the system using silicon powder transfer, melting and shotting on a pseudocontinuous basis is demonstrated. It is proposed to continue the very promising fluid bed work.

  10. Flat-plate solar-array project. Experimental process system development unit for producing semiconductor-grade silicon using the silane-to-silicon process

    NASA Astrophysics Data System (ADS)

    1981-09-01

    The engineering design, fabrication, assembly, operation, economic analysis, and process support R and D for an Experimental Process System Development Unit (EPSDU) are reported. About 95% of purchased equipment is received and will be reshipped to the West Coast location. The Data Collection System is completed. In the area of melting/consolidation, to the system using silicon powder transfer, melting and shotting on a pseudocontinuous basis is demonstrated. It is proposed to continue the very promising fluid bed work.

  11. Using the gene pulser MXcell electroporation system to transfect primary cells with high efficiency.

    PubMed

    McCoy, Adam M; Collins, Michelle L; Ugozzoli, Luis A

    2010-01-01

    It is becoming increasingly apparent that electroporation is the most effective way to introduce plasmid DNA or siRNA into primary cells. The Gene Pulser MXcell electroporation system and Gene Pulser electroporation buffer (Bio-Rad) were specifically developed to easily transfect nucleic acids into mammalian cells and difficult-to-transfect cells, such as primary and stem cells. We will demonstrate how to perform a simple experiment to quickly identify the best electroporation conditions. We will demonstrate how to run several samples through a range of electroporation conditions so that an experiment can be conducted at the same time as optimization is performed. We will also show how optimal conditions identified using 96-well electroporation plates can be used with standard electroporation cuvettes, facilitating the switch from electroporation plates to electroporation cuvettes while maintaining the same electroporation efficiency. In the video, we will also discuss some of the key factors that can lead to the success or failure of electroporation experiments. PMID:20057352

  12. Development of a photoreactive probe-based system for detecting heparin.

    PubMed

    Yabe, Tomio; Hosoda-Yabe, Ritsuko; Sakai, Hiroki; Kanamaru, Yoshihiro; Kiso, Makoto

    2015-03-01

    We previously identified a peptide heparin-associated peptide Y (HappY) that binds specifically to heparin. In this article, we report a novel heparin detection system using chemically modified HappY as a probe. The photoreactive HappY probe was serially diluted and dispensed into a 96-well plate coated with biotinylated heparin. After ultraviolet irradiation, the HappY probe crosslinked to the heparin on the plate was detected with fluorescein isothiocyanate-conjugated streptavidin. Furthermore, the photoreactive HappY probe was used to stain cutaneous tissue sections obtained from dermatitis-affected or mastocytoma-affected cats and dogs. The photoreactive HappY probe stained limited resident mast cells in the connective tissue of skin compared with the anti-heparan sulfate monoclonal antibody 10E4, suggesting that the probe can be used to distinguish the structure of heparin in tissues. The interactions between glycosaminoglycans and proteins in vivo tend to be weak. Therefore, our method for enhancing such weak interactions may be a promising tool for intermolecular interaction studies in glycobiology research.

  13. Characterizing detonator output using dynamic witness plates

    SciTech Connect

    Murphy, Michael John; Adrian, Ronald J

    2009-01-01

    A sub-microsecond, time-resolved micro-particle-image velocimetry (PIV) system is developed to investigate the output of explosive detonators. Detonator output is directed into a transparent solid that serves as a dynamic witness plate and instantaneous shock and material velocities are measured in a two-dimensional plane cutting through the shock wave as it propagates through the solid. For the case of unloaded initiators (e.g. exploding bridge wires, exploding foil initiators, etc.) the witness plate serves as a surrogate for the explosive material that would normally be detonated. The velocity-field measurements quantify the velocity of the shocked material and visualize the geometry of the shocked region. Furthermore, the time-evolution of the velocity-field can be measured at intervals as small as 10 ns using the PIV system. Current experimental results of unloaded exploding bridge wire output in polydimethylsiloxane (PDMS) witness plates demonstrate 20 MHz velocity-field sampling just 300 ns after initiation of the wire.

  14. Characterizing Detonator Output Using Dynamic Witness Plates

    NASA Astrophysics Data System (ADS)

    Murphy, Michael J.; Adrian, Ronald J.

    2009-12-01

    A sub-microsecond, time-resolved micro-particle-image velocimetry (PIV) system is developed to investigate the output of explosive detonators. Detonator output is directed into a transparent solid that serves as a dynamic witness plate and instantaneous shock and material velocities are measured in a two-dimensional plane cutting through the shock wave as it propagates through the solid. For the case of unloaded initiators (e.g. exploding bridge wires, exploding foil initiators, etc.) the witness plate serves as a surrogate for the explosive material that would normally be detonated. The velocity-field measurements quantify the velocity of the shocked material and visualize the geometry of the shocked region. Furthermore, the time-evolution of the velocity-field can be measured at intervals as small as 10 ns using the PIV system. Current experimental results of unloaded exploding bridge wire output in polydimethylsiloxane (PDMS) witness plates demonstrate 20 MHz velocity-field sampling just 300 ns after initiation of the wire.

  15. How mantle slabs drive plate tectonics.

    PubMed

    Conrad, Clinton P; Lithgow-Bertelloni, Carolina

    2002-10-01

    The gravitational pull of subducted slabs is thought to drive the motions of Earth's tectonic plates, but the coupling between slabs and plates is not well established. If a slab is mechanically attached to a subducting plate, it can exert a direct pull on the plate. Alternatively, a detached slab may drive a plate by exciting flow in the mantle that exerts a shear traction on the base of the plate. From the geologic history of subduction, we estimated the relative importance of "pull" versus "suction" for the present-day plates. Observed plate motions are best predicted if slabs in the upper mantle are attached to plates and generate slab pull forces that account for about half of the total driving force on plates. Slabs in the lower mantle are supported by viscous mantle forces and drive plates through slab suction. PMID:12364804

  16. How mantle slabs drive plate tectonics.

    PubMed

    Conrad, Clinton P; Lithgow-Bertelloni, Carolina

    2002-10-01

    The gravitational pull of subducted slabs is thought to drive the motions of Earth's tectonic plates, but the coupling between slabs and plates is not well established. If a slab is mechanically attached to a subducting plate, it can exert a direct pull on the plate. Alternatively, a detached slab may drive a plate by exciting flow in the mantle that exerts a shear traction on the base of the plate. From the geologic history of subduction, we estimated the relative importance of "pull" versus "suction" for the present-day plates. Observed plate motions are best predicted if slabs in the upper mantle are attached to plates and generate slab pull forces that account for about half of the total driving force on plates. Slabs in the lower mantle are supported by viscous mantle forces and drive plates through slab suction.

  17. Ultrabroadband Elastic Cloaking in Thin Plates

    NASA Astrophysics Data System (ADS)

    Farhat, Mohamed; Guenneau, Sebastien; Enoch, Stefan

    2009-07-01

    Control of waves with metamaterials is of great topical interest, and is fueled by rapid progress in broadband acoustic and electromagnetic cloaks. We propose a design for a cloak to control bending waves propagating in isotropic heterogeneous thin plates. This is achieved through homogenization of a multilayered concentric coating filled with piecewise constant isotropic elastic material. Significantly, our cloak displays no phase shift for both backward and forward scattering. To foster experimental efforts, we provide a simplified design of the cloak which is shown to work in a more than two-octave frequency range (30 Hz to 150 Hz) when it consists of 10 layers using only 6 different materials overall. This metamaterial should be easy to manufacture, with potential applications ranging from car industry to antiearthquake passive systems for smart buildings, depending upon the plate dimensions and wavelengths.

  18. Thermal neutron imaging using microchannel plates

    NASA Astrophysics Data System (ADS)

    Fraser, George W.; Pearson, James F.; Al-Horayess, O. S.; Feller, W. Bruce; Cook, Lee M.

    1993-02-01

    Microchannel plates (MCPs) are compact electron multipliers of high gain, widely used for the high resolution imaging of charged particles and photons. In this paper, we consider the use of lead glass MCPs for the imaging of thermal neutrons. Two contrasting techniques are described. The first method involves direct neutron detection within a special channel plate structure containing lithium and/or boron. We review the constraints of glass chemistry on the attainable lithium oxide and boron oxide fractions and, hence, on the maximum neutron detection efficiency. The second method involves the detection, using MCPs of standard glass composition, of the internal conversion electrons from a thin gadolinium foil. We present the first measurements of the detection efficiency, pulse height resolution and imaging properties of a pulse-counting MCP/Gd detector system.

  19. Method for regeneration of electroless nickel plating solution

    DOEpatents

    Eisenmann, E.T.

    1997-03-11

    An electroless nickel(EN)/hypophosphite plating bath is provided employing acetic acid/acetate as a buffer and which is, as a result, capable of perpetual regeneration while avoiding the production of hazardous waste. A regeneration process is provided to process the spent EN plating bath solution. A concentrated starter and replenishment solution is provided for ease of operation of the plating bath. The regeneration process employs a chelating ion exchange system to remove nickel cations from spent EN plating solution. Phosphites are then removed from the solution by precipitation. The nickel cations are removed from the ion exchange system by elution with hypophosphorus acid and the nickel concentration of the eluate adjusted by addition of nickel salt. The treated solution and adjusted eluate are combined, stabilizer added, and the volume of resulting solution reduced by evaporation to form the bath starter and replenishing solution. 1 fig.

  20. Method for regeneration of electroless nickel plating solution

    DOEpatents

    Eisenmann, Erhard T.

    1997-01-01

    An electroless nickel(EN)/hypophosphite plating bath is provided employing acetic acid/acetate as a buffer and which is, as a result, capable of perpetual regeneration while avoiding the production of hazardous waste. A regeneration process is provided to process the spent EN plating bath solution. A concentrated starter and replenishment solution is provided for ease of operation of the plating bath. The regeneration process employs a chelating ion exchange system to remove nickel cations from spent EN plating solution. Phosphites are then removed from the solution by precipitation. The nickel cations are removed from the ion exchange system by elution with hypophosphorous acid and the nickel concentration of the eluate adjusted by addition of nickel salt. The treated solution and adjusted eluate are combined, stabilizer added, and the volume of resulting solution reduced by evaporation to form the bath starter and replenishing solution.