Science.gov

Sample records for 96-well plate system

  1. Electrothermal micromixing in 96 well plate

    NASA Astrophysics Data System (ADS)

    Kauffmann, Paul; Loire, Sophie; Mezic, Igor

    2011-11-01

    Diagnostic and pharmacology processes could be greatly accelerated by appropriate mixing. Here electrothermal flows are explored to provide mixing of conductive physiological solutions (=1.6 S/m) in a 96 well plate. Three interdigitated electrodes provide an electric field (< 15Vpp, 1MHz) beneath each well. Polarization and conduction phenomenon of the fluid in a well will be first modeled numerically and compared to an electrical circuit model. Due to high conductivity and permittivity of the fluid, the impedance of the array of filled wells collapse dramatically (96 wells: R = 1Ohm, C=250nF). The power supply challenges accordingly raised by arrays of electrothermal micromixers will be then analyzed. The efficiency of different methods of mixing in those wells will be also compared: the addition of low frequency signal leading to AC electro-osmotic perturbations, a blinking vortices method. The experimental results will be compared to simulations.

  2. Is biofilm removal properly assessed? Comparison of different quantification methods in a 96-well plate system.

    PubMed

    Stiefel, Philipp; Rosenberg, Urs; Schneider, Jana; Mauerhofer, Stefan; Maniura-Weber, Katharina; Ren, Qun

    2016-05-01

    Various methods have been reported to quantify total biofilm or different components of biofilm; however, these methods are often confusedly used, leading to discrepancies and misleading results. In this study, different methods for quantification of biofilm, including those for total biomass, total amount of bacterial cells, viable cell number, and amount of extracellular polymeric substances, were systematically compared in microtiter plates. To evaluate which method is suitable for assessment of biofilm removal and for bacterial killing, biofilm samples were treated with various cleaners possessing removing and/or killing capacities. It was found that most of the methods tested in this study in general exhibited high reproducibility and repeatability. Crystal Violet staining was a simple but reliable method for total biomass quantification. Total bacteria cell numbers could be reliably quantified by the fluorescent DNA-binding dye Acridine Orange. Viable cells could be quantified by either an ATP-based assay or a proliferation assay. Both of these viability methods showed a broad detection range and led to precise measurement. For quantification of proteins in the biofilm, staining with fluorescein isothiocyanate was most suitable. Furthermore, it was revealed that a combination of different methods is required to determine if a cleaner kills or removes biofilm. PMID:26923144

  3. Scalable 96-well Plate Based iPSC Culture and Production Using a Robotic Liquid Handling System

    PubMed Central

    Conway, Michael K.; Gerger, Michael J.; Balay, Erin E.; O'Connell, Rachel; Hanson, Seth; Daily, Neil J.; Wakatsuki, Tetsuro

    2015-01-01

    Continued advancement in pluripotent stem cell culture is closing the gap between bench and bedside for using these cells in regenerative medicine, drug discovery and safety testing. In order to produce stem cell derived biopharmaceutics and cells for tissue engineering and transplantation, a cost-effective cell-manufacturing technology is essential. Maintenance of pluripotency and stable performance of cells in downstream applications (e.g., cell differentiation) over time is paramount to large scale cell production. Yet that can be difficult to achieve especially if cells are cultured manually where the operator can introduce significant variability as well as be prohibitively expensive to scale-up. To enable high-throughput, large-scale stem cell production and remove operator influence novel stem cell culture protocols using a bench-top multi-channel liquid handling robot were developed that require minimal technician involvement or experience. With these protocols human induced pluripotent stem cells (iPSCs) were cultured in feeder-free conditions directly from a frozen stock and maintained in 96-well plates. Depending on cell line and desired scale-up rate, the operator can easily determine when to passage based on a series of images showing the optimal colony densities for splitting. Then the necessary reagents are prepared to perform a colony split to new plates without a centrifugation step. After 20 passages (~3 months), two iPSC lines maintained stable karyotypes, expressed stem cell markers, and differentiated into cardiomyocytes with high efficiency. The system can perform subsequent high-throughput screening of new differentiation protocols or genetic manipulation designed for 96-well plates. This technology will reduce the labor and technical burden to produce large numbers of identical stem cells for a myriad of applications. PMID:26068617

  4. Scalable 96-well Plate Based iPSC Culture and Production Using a Robotic Liquid Handling System.

    PubMed

    Conway, Michael K; Gerger, Michael J; Balay, Erin E; O'Connell, Rachel; Hanson, Seth; Daily, Neil J; Wakatsuki, Tetsuro

    2015-01-01

    Continued advancement in pluripotent stem cell culture is closing the gap between bench and bedside for using these cells in regenerative medicine, drug discovery and safety testing. In order to produce stem cell derived biopharmaceutics and cells for tissue engineering and transplantation, a cost-effective cell-manufacturing technology is essential. Maintenance of pluripotency and stable performance of cells in downstream applications (e.g., cell differentiation) over time is paramount to large scale cell production. Yet that can be difficult to achieve especially if cells are cultured manually where the operator can introduce significant variability as well as be prohibitively expensive to scale-up. To enable high-throughput, large-scale stem cell production and remove operator influence novel stem cell culture protocols using a bench-top multi-channel liquid handling robot were developed that require minimal technician involvement or experience. With these protocols human induced pluripotent stem cells (iPSCs) were cultured in feeder-free conditions directly from a frozen stock and maintained in 96-well plates. Depending on cell line and desired scale-up rate, the operator can easily determine when to passage based on a series of images showing the optimal colony densities for splitting. Then the necessary reagents are prepared to perform a colony split to new plates without a centrifugation step. After 20 passages (~3 months), two iPSC lines maintained stable karyotypes, expressed stem cell markers, and differentiated into cardiomyocytes with high efficiency. The system can perform subsequent high-throughput screening of new differentiation protocols or genetic manipulation designed for 96-well plates. This technology will reduce the labor and technical burden to produce large numbers of identical stem cells for a myriad of applications. PMID:26068617

  5. Quantification of cells cultured on 96-well plates.

    PubMed

    Kueng, W; Silber, E; Eppenberger, U

    1989-10-01

    The method for cell number measurement in monolayer cultures by crystal violet staining published recently by Gillies et al. (R. G. Gillies, N. Didier, M. Denton (1986) Anal. Biochem. 159, 109-113) was modified and significantly improved. The procedure was adapted for use in 96-well plates since the method is inherently very sensitive. Modifications allowed fast and complete solubilization of dye adsorbed by cell nuclei during staining. Since light absorption of the unstained or destained cell layers is negligible, cell number measurements can be performed in the respective wells. Due to these features, multiple assays may be carried out rapidly using standard 96-well plate readers. In addition, it is shown that the sensitivity of the assay can be varied and easily controlled by choosing the appropriate pH during the staining procedure. This increases the flexibility of the method making it useful for determining cell density of a wide range of different cell types. PMID:2604040

  6. Lactobacillus casei microbiological assay of folic acid derivatives in 96-well microtiter plates.

    PubMed

    Horne, D W; Patterson, D

    1988-11-01

    Microbiological assay is still widely used for estimating folic acid derivatives in serum and other biological samples. We describe here a modification of this procedure involving use of 96-well microtiter plates. This procedure, used with modern, computer-interfaced microtiter-plate readers and data-reduction software, greatly shortens the time and minimizes reagent costs for this assay. Under the conditions of our assay procedures, all folic acid derivatives tested gave equal growth response for Lactobacillus casei. Results for assays of rat liver extracts showed excellent agreement between the standard bioassay and the 96-well procedure. PMID:3141087

  7. HIGHLY SENSITIVE ASSAY FOR ANTICHOLINESTERASE COMPOUNDS USING 96 WELL PLATE FORMAT

    EPA Science Inventory

    The rapid and sensitive detection of organophosphate insecticides using a 96 well plate format is reported. Several features of this assay make it attractive for development as a laboratory-based or field screening assay. Acetylcholinesterase (AChE) was stabilized in a gelati...

  8. Toward Microbioreactor Arrays: A Slow-Responding Oxygen Sensor for Monitoring of Microbial Cultures in Standard 96-Well Plates.

    PubMed

    Glauche, Florian; John, Gernot T; Arain, Sarina; Knepper, Andreas; Neubauer, Antje; Goelling, Detlef; Lang, Christine; Violet, Norman; King, Rudibert; Neubauer, Peter

    2015-08-01

    In this study, a slow-responding chemo-optical sensor for dissolved oxygen (DO) integrated into a 96-well plate was developed. The slow response time ensures that the measured oxygen value does not change much during plate transport to the microplate reader. The sensor therefore permits at-line DO measurement of microbial cultures. Moreover, it eliminates the necessity of individual optical measurement systems for each culture plate, as many plates can be measured successively. Combined with the 96-well format, this increases the experimental throughput enormously. The novel sensor plate (Slow OxoPlate) consists of fluorophores suspended in a polymer matrix that were placed into u-bottom 96-well plates. Response time was measured using sodium sulfite, and a t90 value of 9.7 min was recorded. For application, DO values were then measured in Escherichia coli and Saccharomyces cerevisiae cultures grown under fed-batch-like conditions. Depending on the DO sensor's response time, different information on the oxygenation state of the culture plate was obtained: a fast sensor variant detects disturbance through sampling, whereas the slow sensor indicates oxygen limitation during incubation. A combination of the commercially available OxoPlate and the Slow OxoPlate enables operators of screening facilities to validate their cultivation procedures with regard to oxygen availability. PMID:25720599

  9. Measuring oxidative stress resistance of Caenorhabditis elegans in 96-well microtiter plates.

    PubMed

    Possik, Elite; Pause, Arnim

    2015-01-01

    Oxidative stress, which is the result of an imbalance between production and detoxification of reactive oxygen species, is a major contributor to chronic human disorders, including cardiovascular and neurodegenerative diseases, diabetes, aging, and cancer. Therefore, it is important to study oxidative stress not only in cell systems but also using whole organisms. C. elegans is an attractive model organism to study the genetics of oxidative stress signal transduction pathways, which are highly evolutionarily conserved. Here, we provide a protocol to measure oxidative stress resistance in C. elegans in liquid. Briefly, ROS-inducing reagents such as paraquat (PQ) and H2O2 are dissolved in M9 buffer, and solutions are aliquoted in the wells of a 96 well microtiter plate. Synchronized L4/young adult C. elegans animals are transferred to the wells (5-8 animals/well) and survival is measured every hour until most worms are dead. When performing an oxidative stress resistance assay using a low concentration of stressors in plates, aging might influence the behavior of animals upon oxidative stress, which could lead to an incorrect interpretation of the data. However, in the assay described herein, this problem is unlikely to occur since only L4/young adult animals are being used. Moreover, this protocol is inexpensive and results are obtained in one day, which renders this technique attractive for genetic screens. Overall, this will help to understand oxidative stress signal transduction pathways, which could be translated into better characterization of oxidative stress-associated human disorders. PMID:25993260

  10. Biofilm Localization in the Vertical Wall of Shaking 96-Well Plates

    PubMed Central

    Gomes, Luciana C.; Moreira, Joana M. R.; Simões, Manuel; Melo, Luís F.; Mergulhão, Filipe J.

    2014-01-01

    Microtiter plates with 96 wells are being increasingly used for biofilm studies due to their high throughput, low cost, easy handling, and easy application of several analytical methods to evaluate different biofilm parameters. These methods provide bulk information about the biofilm formed in each well but lack in detail, namely, regarding the spatial location of the biofilms. This location can be obtained by microscopy observation using optical and electron microscopes, but these techniques have lower throughput and higher cost and are subjected to equipment availability. This work describes a differential crystal violet (CV) staining method that enabled the determination of the spatial location of Escherichia coli biofilms formed in the vertical wall of shaking 96-well plates. It was shown that the biofilms were unevenly distributed on the wall with denser cell accumulation near the air-liquid interface. The results were corroborated by scanning electron microscopy and a correlation was found between biofilm accumulation and the wall shear strain rates determined by computational fluid dynamics. The developed method is quicker and less expensive and has a higher throughput than the existing methods available for spatial location of biofilms in microtiter plates. PMID:24834360

  11. Stability test for amorphous materials in humidity controlled 96-well plates by near-infrared spectroscopy.

    PubMed

    Otsuka, Makoto; Tanabe, Hideaki

    2012-03-01

    The purpose of this research is to apply near infrared spectrometry (NIR) with chemoinformetrics to predict the change of crystalline properties of indomethacin (IMC) amorphous under various levels of relative humidity storage conditions. Stability test for amorphous and meta-stable polymorphic forms was performed in humidity controlled the modified 96-well quartz plates containing various kinds of saturated salt solutions (0-100% of relative humidity (RH)) by NIR spectroscopy. Amorphous form was obtained melt product to pour into liquid nitrogen and after then ground. Samples were stored at 25°C in the 6-well plates at various levels of RH. The spectra of the powder samples were measured by the reflectance FT-NIR spectrometer. The second derivative spectra of form α showed specific absorption peaks at 4980, 6036, 7296 and 8616 cm-1 and that of form γ showed those at 5020, 5028, 7344, 7428 and 8436 cm-1. After storage at less than 50% RH, the peak intensities at 5020, 5028, 7344, 7428 and 8436 cm-1 of the amorphous solid increased with increasing of storage time. However, the peak intensity at 4980, 6036 and 7296 cm-1 increased at more than 50% RH Please check and confirm the edit. The results suggested that at lower humidity, the IMC amorphous solid transformed into form γ, but it transformed into form α at more than high humidity. It is possible that crystalline stability of the pharmaceutical preparations could be predicted by using humidity controlled 96-well plates and reflectance NIR-chemoinformetric methods. PMID:21942281

  12. A rapid direct telomerase assay method using 96-well streptavidin plates.

    PubMed

    Francis, Rawle; Friedman, Simon H

    2002-05-01

    We have developed a high-throughput direct assay methodfor the assay of telomerase activity that improves on previous direct telomerase assays in two ways that allow larger numbers of samples to be conveniently processed: (i) 96-well streptavidin coated plates are used to bind and wash biotinylated primer extension products from the telomerase assay, as opposed to tubes containing streptavidin-coated magnetic beads; and (ii) storage phosphor-imagery is used instead of film autoradiography to detect telomerase products after being washed and released from the streptavidin-derivatized matrix. This method improves on previous direct assay methods using magnetic beads by allowing larger numbers of samples to be conveniently assayed. Also, the total activity of the radiolabeled nucleotides used in this procedure is significantly lower than that used in standard direct telomerase assays, lowering costs and exposure to radioactivity. We have validated the assay by repeating, in triplicate, the IC50 determination of rivanol, our previously identified telomerase inhibitor. PMID:12019789

  13. Establishment of ATP-based luciferase viability assay in 96-well plate for Trypanosoma congolense.

    PubMed

    Suganuma, Keisuke; Allamanda, Puttik; Hakimi, Hassan; Zhou, Mo; Angeles, Jose Ma; Kawazu, Shin-ichiro; Inoue, Noboru

    2014-11-01

    Animal African trypanosomosis (AAT), caused by Trypanosoma congolense, is widespread throughout sub-Saharan Africa. There are significant concerns related to the current drugs available for the treatment of AAT due to their limited effectiveness across species and their adverse effects. Moreover, drug resistant trypanosomes have recently been reported in the field. High throughput screening (HTS) of large chemical compound library collections is a promising approach for identifying novel drug candidates. While HTS for Trypanozoon trypanosomes, T. brucei sspp. and T. evansi is well established, no assays have been developed for T. congolense. In the present study, the authors developed an ATP-based luciferase viability assay for T. congolense in a 96-well plate format. The calculated 50% inhibitory concentration (IC50) values for pentamidine and diminazene were 10-100 times higher in T. congolense than in T. brucei. This result suggests that the transporters for the 2 tested compounds differ between T. congolense and T. brucei. This assay could further be applied to screen novel chemical compounds for the treatment of AAT caused by T. congolense. PMID:25056575

  14. Establishment of ATP-Based Luciferase Viability Assay in 96-Well Plate for Trypanosoma congolense

    PubMed Central

    SUGANUMA, Keisuke; ALLAMANDA, Puttik; HAKIMI, Hassan; ZHOU, Mo; ANGELES, Jose Ma.; KAWAZU, Shin-ichiro; INOUE, Noboru

    2014-01-01

    ABSTRACT Animal African trypanosomosis (AAT), caused by Trypanosoma congolense, is widespread throughout sub-Saharan Africa. There are significant concerns related to the current drugs available for the treatment of AAT due to their limited effectiveness across species and their adverse effects. Moreover, drug resistant trypanosomes have recently been reported in the field. High throughput screening (HTS) of large chemical compound library collections is a promising approach for identifying novel drug candidates. While HTS for Trypanozoon trypanosomes, T. brucei sspp. and T. evansi is well established, no assays have been developed for T. congolense. In the present study, the authors developed an ATP-based luciferase viability assay for T. congolense in a 96-well plate format. The calculated 50% inhibitory concentration (IC50) values for pentamidine and diminazene were 10–100 times higher in T. congolense than in T. brucei. This result suggests that the transporters for the 2 tested compounds differ between T. congolense and T. brucei. This assay could further be applied to screen novel chemical compounds for the treatment of AAT caused by T. congolense. PMID:25056575

  15. Urine sample preparation in 96-well filter plates for quantitative clinical proteomics.

    PubMed

    Yu, Yanbao; Suh, Moo-Jin; Sikorski, Patricia; Kwon, Keehwan; Nelson, Karen E; Pieper, Rembert

    2014-06-01

    Urine is an important, noninvasively collected body fluid source for the diagnosis and prognosis of human diseases. Liquid chromatography mass spectrometry (LC-MS) based shotgun proteomics has evolved as a sensitive and informative technique to discover candidate disease biomarkers from urine specimens. Filter-aided sample preparation (FASP) generates peptide samples from protein mixtures of cell lysate or body fluid origin. Here, we describe a FASP method adapted to 96-well filter plates, named 96FASP. Soluble urine concentrates containing ~10 μg of total protein were processed by 96FASP and LC-MS resulting in 700-900 protein identifications at a 1% false discovery rate (FDR). The experimental repeatability, as assessed by label-free quantification and Pearson correlation analysis for shared proteins among replicates, was high (R ≥ 0.97). Application to urinary pellet lysates which is of particular interest in the context of urinary tract infection analysis was also demonstrated. On average, 1700 proteins (±398) were identified in five experiments. In a pilot study using 96FASP for analysis of eight soluble urine samples, we demonstrated that protein profiles of technical replicates invariably clustered; the protein profiles for distinct urine donors were very different from each other. Robust, highly parallel methods to generate peptide mixtures from urine and other body fluids are critical to increase cost-effectiveness in clinical proteomics projects. This 96FASP method has potential to become a gold standard for high-throughput quantitative clinical proteomics. PMID:24797144

  16. Development of a novel bead-based 96-well filtration plate competitive immunoassay for the detection of Gentamycin.

    PubMed

    Ho, Tien Yu Jessica; Chan, Chia-Chung; Chan, KinGho; Wang, Yu Chieh; Lin, Jing-Tang; Chang, Cheng-Ming; Chen, Chien-Sheng

    2013-11-15

    We developed a sensitive, simple, inexpensive and rapid bead-based immunoassay platform, composed of liposomal nanovesicle amplification system, Gentamycin sulfate beads and 96-well filtration plates. In the beginning of the assay, Gentamycin sulfate beads, Gentamycin sulfate and Gentamycin specific antibody were incubated in a bottom-sealed 96-well filtration plate. After incubation, washing was done by running washing buffer through the unsealed filtration plate with only gravity and the antibody-Gentamycin bead complexes were retained in the plate. Fluorescent dye-loaded protein G-liposomal nanovesicles were then added to specifically bind to antibodies on the retained beads. After washing unbound nanovesicles, millions of fluorescent dye molecules were released by adding a detergent solution to lyse liposomal nanovesicles. The limit of detection (LOD) of this novel detection platform in TBS and in skim milk were 52.65 ng/mL and 14.16 ng/mL, which are both sufficient for detecting the 200 ng/mL Codex maximum residual level (MRL). The dynamic ranges were both from each of their LODs to 100 μg/mL. The 50% inhibition concentrations (IC50) in TBS and skim milk were 199.66 ng/mL and 360.81 ng/mL, respectively. We also demonstrated the good specificity of this platform by comparing detection results between pure Gentamycin solution and a mixture solution of 6 different antibiotics including Gentamycin in skim milk. The entire assay with 60 samples was conducted within 2h. In sum, this novel biosensing platform not only fulfilled most benefits of magnetic bead-based assays, but also was inexpensive and convenient by replacing the magnetic separation with filtration plate separation. PMID:23728198

  17. Ice-Cap: a method for growing Arabidopsis and tomato plants in 96-well plates for high-throughput genotyping.

    PubMed

    Su, Shih-Heng; Clark, Katie A; Gibbs, Nicole M; Bush, Susan M; Krysan, Patrick J

    2011-01-01

    It is becoming common for plant scientists to develop projects that require the genotyping of large numbers of plants. The first step in any genotyping project is to collect a tissue sample from each individual plant. The traditional approach to this task is to sample plants one-at-a-time. If one wishes to genotype hundreds or thousands of individuals, however, using this strategy results in a significant bottleneck in the genotyping pipeline. The Ice-Cap method that we describe here provides a high-throughput solution to this challenge by allowing one scientist to collect tissue from several thousand seedlings in a single day (1,2). This level of throughput is made possible by the fact that tissue is harvested from plants 96-at-a-time, rather than one-at-a-time. The Ice-Cap method provides an integrated platform for performing seedling growth, tissue harvest, and DNA extraction. The basis for Ice-Cap is the growth of seedlings in a stacked pair of 96-well plates. The wells of the upper plate contain plugs of agar growth media on which individual seedlings germinate. The roots grow down through the agar media, exit the upper plate through a hole, and pass into a lower plate containing water. To harvest tissue for DNA extraction, the water in the lower plate containing root tissue is rapidly frozen while the seedlings in the upper plate remain at room temperature. The upper plate is then peeled away from the lower plate, yielding one plate with 96 root tissue samples frozen in ice and one plate with 96 viable seedlings. The technique is named "Ice-Cap" because it uses ice to capture the root tissue. The 96-well plate containing the seedlings can then wrapped in foil and transferred to low temperature. This process suspends further growth of the seedlings, but does not affect their viability. Once genotype analysis has been completed, seedlings with the desired genotype can be transferred from the 96-well plate to soil for further propagation. We have demonstrated

  18. MStern Blotting-High Throughput Polyvinylidene Fluoride (PVDF) Membrane-Based Proteomic Sample Preparation for 96-Well Plates.

    PubMed

    Berger, Sebastian T; Ahmed, Saima; Muntel, Jan; Cuevas Polo, Nerea; Bachur, Richard; Kentsis, Alex; Steen, Judith; Steen, Hanno

    2015-10-01

    We describe a 96-well plate compatible membrane-based proteomic sample processing method, which enables the complete processing of 96 samples (or multiples thereof) within a single workday. This method uses a large-pore hydrophobic PVDF membrane that efficiently adsorbs proteins, resulting in fast liquid transfer through the membrane and significantly reduced sample processing times. Low liquid transfer speeds have prevented the useful 96-well plate implementation of FASP as a widely used membrane-based proteomic sample processing method. We validated our approach on whole-cell lysate and urine and cerebrospinal fluid as clinically relevant body fluids. Without compromising peptide and protein identification, our method uses a vacuum manifold and circumvents the need for digest desalting, making our processing method compatible with standard liquid handling robots. In summary, our new method maintains the strengths of FASP and simultaneously overcomes one of the major limitations of FASP without compromising protein identification and quantification. PMID:26223766

  19. IDENTIFICATION OF SALMONELLA-POSITIVE FECAL SAMPLES USING A 96-WELL MICROCULTURE PLATE TECHNIQUE (RX METHOD)

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Conventional Salmonella isolation involves multiple sample transfers to culture media performed by an experienced microbiologist. The modified semi-solid RV and XLT (RX) Plate method, a modification of the RX tube format designed by Gailey et al. (2004), consolidates pre-enrichment (buffered pepton...

  20. SIMPLE DEVICE TO DELIVER BEADS TO 96-WELL PLATES FOR RAPID RESUSPENSION OF CELLS

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Genomic sequencing involves sequence determination of inserts from a large numbers of plasmids of a genomic library. In high throughput DNA sequencing projects, cultures are grown in a 96-deep well plate format, centrifuged, and resuspended. Resuspension of cells was aided by use of a simple devic...

  1. Human tear analysis with miniaturized multiplex cytokine assay on “wall-less” 96-well plate

    PubMed Central

    Quah, Joanne; Tong, Louis; Kim, Namyong

    2015-01-01

    Purpose Tears are a particularly limited body fluid and commonly used in the diagnosis of patients who have ocular diseases. A popular method for analysis of ocular inflammation in tears uses Luminex® bead multiplex technology to generate valuable multiple cytokine profile outputs with 25–50 µl tear sample volume. We propose a method for measuring tear cytokines with 5 μl tear sample volume and 80% reduced Luminex reagents compared to previous protocols. Methods Using human tears pooled from 1,000 participants, the DA-Bead-based method running at 5–20 µl volume, using manual pipetting, in conjunction with a magnetic Luminex cytokine (four-plex) panel assay in a 96-well format was performed and validated for tumor necrosis factor (TNF)-α, interferon (IFN)-γ, interleukin (IL)-1β, and IL-6. Results Upon use of the DA-Bead method at the 5 μl volume with cytokine standards, the concentrations of each of the four cytokines were found to be linear over a range of 3.5–4 log pg/ml with an intra-assay coefficient of variation (CV) ≤5%, inter-assay %CV ≤10%, and accuracy within the 70–130% range. Upon use of a 5 µl healthy pooled tear sample, cytokine concentrations were detected with a precision intra-assay %CV ˂ 20% for IL-6, IFN-γ, or TNF-α or 30.37% with IL-1β. The inter-assay %CV with tears was ≤20.84% for all cytokines. Tear volumes run at 5 μl on DA-Bead produced a similar cytokine expression profile at a 1-month interval and were highly correlated with the larger 10 μl–based tear sample volume cytokine profile with R2 = 0.98. Conclusions DA-Bead assay is highly sensitive and reproducible and has a performance profile that is potentially suitable for use in standard clinical scenarios. Considering the use of as little as 5 µl of assay beads and 5 µl sample, this is also likely to reduce the assay cost significantly and ease diagnosis of patients with ocular diseases. PMID:26539027

  2. A Novel 96well-formatted Micro-gap Plate Enabling Drug Response Profiling on Primary Tumour Samples

    NASA Astrophysics Data System (ADS)

    Ma, Wei-Yuan; Hsiung, Lo-Chang; Wang, Chen-Ho; Chiang, Chi-Ling; Lin, Ching-Hung; Huang, Chiun-Sheng; Wo, Andrew M.

    2015-04-01

    Drug-based treatments are the most widely used interventions for cancer management. Personalized drug response profiling remains inherently challenging with low cell count harvested from tumour sample. We present a 96well-formatted microfluidic plate with built-in micro-gap that preserves up to 99.2% of cells during multiple assay/wash operation and only 9,000 cells needed for a single reagent test (i.e. 1,000 cells per test spot x 3 selected concentration x triplication), enabling drug screening and compatibility with conventional automated workstations. Results with MCF7 and MDA-MB-231 cell lines showed that no statistical significance was found in dose-response between the device and conventional 96-well plate control. Primary tumour samples from breast cancer patients tested in the device also showed good IC50 prediction. With drug screening of primary cancer cells must consider a wide range of scenarios, e.g. suspended/attached cell types and rare/abundant cell availability, the device enables high throughput screening even for suspended cells with low cell count since the signature microfluidic cell-trapping feature ensures cell preservation in a multiple solution exchange protocol.

  3. Development of a fluorimetric multispecies 96-well micro-plate growth test for screening metal toxicity to phytoplankton

    SciTech Connect

    Peterson, H.G.; Ruecker, N.J.; Cantin, I.A.; Nyholm, N.; Dal-Jensen, S.

    1995-12-31

    The rapid and cost-effective screening of industrial waste is an ideal approach to regulations that offer true protection of aquatic habitats. For these tests to be ecologically important protection of large groups of organisms is also essential. This can best be done by testing batteries of species. Photosynthetic organisms compose 99.9% of habitats as well as providing food for higher trophic levels. A test was developed that can accommodate the testing of most phytoplanktonic species irrespective of morphology (unicellular, multicellular, colonial, filamentous). Forty eight to 72 h growth tests were carried out with green algae, diatoms, and cyanobacteria. The algae were incubated with different levels of toxicants in 96-well microplates which were read in a 96-well fluorometric plate reader. Phytoplankton emitting low levels of fluorescence can be incubated with DCMU, which can increase the fluorescent signal 2 to 4 times. The data from the plate reader is transferred to a computer spreadsheet and inhibition levels are automatically calculated. Eleven metal mining wastes from across Canada were tested against this method using the following phytoplanktonic species: Selenastrum, Nannochloris (green algae), Nitzschia (diatom), Microcystis, and Pseudoanabaena (cyanobacteria). These wastes were also screened against Microtox. All wastes were highly toxic to the tested phytoplankton, but only 4 were toxic to Microtox{trademark}.

  4. Automation of cell-based drug absorption assays in 96-well format using permeable support systems.

    PubMed

    Larson, Brad; Banks, Peter; Sherman, Hilary; Rothenberg, Mark

    2012-06-01

    Cell-based drug absorption assays, such as Caco-2 and MDCK-MDR1, are an essential component of lead compound ADME/Tox testing. The permeability and transport data they provide can determine whether a compound continues in the drug discovery process. Current methods typically incorporate 24-well microplates and are performed manually. Yet the need to generate absorption data earlier in the drug discovery process, on an increasing number of compounds, is driving the use of higher density plates. A simple, more efficient process that incorporates 96-well permeable supports and proper instrumentation in an automated process provides more reproducible data compared to manual methods. Here we demonstrate the ability to perform drug permeability and transport assays using Caco-2 or MDCKII-MDR1 cells. The assay procedure was automated in a 96-well format, including cell seeding, media and buffer exchanges, compound dispense, and sample removal using simple robotic instrumentation. Cell monolayer integrity was confirmed via transepithelial electrical resistance and Lucifer yellow measurements. Proper cell function was validated by analyzing apical-to-basolateral and basolateral-to-apical movement of rhodamine 123, a known P-glycoprotein substrate. Apparent permeability and efflux data demonstrate how the automated procedure provides a less variable method than manual processing, and delivers a more accurate assessment of a compound's absorption characteristics. PMID:22357561

  5. 96-Well Plate Colorimetric Assay for K(sub i) Determination of (plusmn)-2-Benzylsuccinic Acid, an Inhibitor of Carboxypeptidase A

    ERIC Educational Resources Information Center

    Wentland, Mark P.; Raza, Shaan; Yingtong Gao

    2004-01-01

    An appropriate assay to determine the inhibition potency of carboxypeptidase A (CPA) in 96-well format to illustrate how high throughput screening is used in modern drug discovery to identify bioactive molecules is developed. Efforts in developing a colorimetric 96-well plate assay for determination of the K(sub i) for inhibition of CPA by…

  6. Facile preparation of a photoactivatable surface on a 96-well plate: a versatile and multiplex cell migration assay platform.

    PubMed

    Kamimura, Masao; Scheideler, Olivia; Shimizu, Yoshihisa; Yamamoto, Shota; Yamaguchi, Kazuo; Nakanishi, Jun

    2015-06-01

    Cell migration is an essential cellular activity in various physiological and pathological processes, such as wound healing and cancer metastasis. Therefore, in vitro cell migration assays are important not only for fundamental biological studies but also for evaluating potential drugs that control cell migration activity in medical applications. In this regard, robust control over cell migrating microenvironments is critical for reliable and quantitative analysis as cell migration is highly dependent upon the microenvironments. Here, we developed a facile method for making a commercial glass-bottom 96-well plate photoactivatable for cell adhesion, aiming to develop a versatile and multiplex cell migration assay platform. Cationic poly-d-lysine was adsorbed to the anionic glass surface via electrostatic interactions and, subsequently, functionalized with poly(ethylene glycol) (PEG) bearing a photocleavable reactive group. The initial PEGylated surface is non-cell-adhesive. However, upon near-ultraviolet (UV) irradiation, the photorelease of PEG switches the surface from non-biofouling to cell-adhesive. With this platform, we assayed cell migration in the following procedure: (1) create cell-attaching regions of precise geometries by controlled photoirradiation, (2) seed cells to allow them to attach selectively to the irradiated regions, (3) expose UV light to the remaining PEGylated regions to extend the cell-adhesive area, (4) analyse cell migration using microscopy. Surface modification of the glass surface was characterized by ζ-potential and contact angle measurements. The PEGylated surface showed cell-resistivity and became cell-adhesive upon releasing PEG by near-UV irradiation. The method was applied for parallelly evaluating the effect of model drugs on the migration of epithelial MDCK cells in the multiplexed platform. The dose-response relationship for cytochalasin D treatment on cell migration behavior was successfully evaluated with high

  7. Collection, storage, and filtration of in vivo study samples using 96-well filter plates to facilitate automated sample preparation and LC/MS/MS analysis.

    PubMed

    Berna, M; Murphy, A T; Wilken, B; Ackermann, B

    2002-03-01

    The benefits of high-throughput bioanalysis within the pharmaceutical industry are well established. One of the most significant bottlenecks in bioanalysis is transferring in vivo-generated study samples from their collection tubes during sample preparation and extraction. In most cases, the plasma samples must be stored frozen prior to analysis, and the freeze/thaw (F/T) process introduces thrombin clots that are capable of plugging pipets and automated liquid-transfer systems. A new approach to dealing with this problem involves the use of Ansys Captiva 96-well 20-microm polypropylene filter plates to collect, store frozen, and filter plasma samples prior to bioanalysis. The samples are collected from the test subjects, and the corresponding plasma samples are placed directly into the wells of the filter plate. Two Duoseal (patent pending) covers are used to seal the top and bottom of the plate, and the plate is stored at down to -70 degrees C. Prior to sample analysis, the seals are removed and the plate is placed in a 96-well SPE manifold. As the plasma thaws, it passes (by gravity or mild vacuum) through the polypropylene filter into a 96-well collection plate. A multichannel pipet or automated liquid-transfer system is used to transfer sample aliquots without fear of plugging. A significant advantage of this approach is that, unlike other methods, issues related to incomplete pipetting are virtually eliminated. The entire process is rapid since thawing and filtering take place simultaneously, and if a second F/T cycle is required for reanalysis, it is not necessary to refilter the samples (additional clotting was not observed after three F/T cycles). This technique was tested using monkey, rat, and dog plasma and sodium heparin and EDTA anticoagulants. To assess the possibility of nonspecific binding to the polypropylene filter, a variety of drug candidates from diverse drug classes were studied. Validation data generated for two Lilly compounds from distinct

  8. Quantum dot immunoassays in renewable surface column and 96-well plate formats for the fluorescence detection of Botulinum neurotoxin using high-affinity antibodies

    SciTech Connect

    Warner, Marvin G.; Grate, Jay W.; Tyler, Abby J.; Ozanich, Richard M.; Miller, Keith D.; Lou, Jianlong; Marks, James D.; Bruckner-Lea, Cindy J.

    2009-09-01

    A fluorescence sandwich immunoassay using high affinity antibodies and quantum dot (QD) reporters has been developed for detection of botulinum toxin serotype A (BoNT/A). For the development of the assay, a nontoxic recombinant fragment of the holotoxin (BoNT/A-HC-fragment) has been used as a structurally valid simulant for the full toxin molecule. The antibodies used, AR4 and RAZ1, bind to nonoverlapping epitopes present on both the full toxin and on the recombinant fragment. In one format, the immunoassay is carried out in a 96-well plate with detection in a standard plate reader. Detection down to 31 pM of the BoNT/Hc-fragment was demonstrated with a total incubation time of 3 hours, using AR4 as the capture antibody and QD-coupled RAZ1 as the reporter. In a second format, the AR4 capture antibody was coupled to Sepharose beads, and the immunochemical reactions were carried out in microcentrifuge tubes with an incubation time of 1 hour. These beads were subsequently captured and concentrated in a rotating rod “renewable surface” flow cell as part of a sequential injection fluidic system. This flow cell was equipped with a fiber optic system for fluorescence measurements. In PBS buffer solution matrix, the BoNT/A-HC-fragment was detected to concentrations as low as 5 pM using the fluidic measurement approach.

  9. Quantum dot immunoassays in renewable surface column and 96-well plate formats for the fluorescence detection of Botulinum neurotoxin using high-affinity antibodies

    PubMed Central

    Grate, Jay W.; Tyler, Abby; Ozanich, Richard M.; Miller, Keith D.; Lou, Jianlong; Marks, James D.; Bruckner-Lea, Cynthia J.

    2009-01-01

    A fluorescence sandwich immunoassay using high affinity antibodies and quantum dot (QD) reporters has been developed for detection of botulinum neurotoxin serotype A (BoNT/A) using a nontoxic recombinant fragment of the holotoxin (BoNT/A-HC-fragment) as a structurally valid simulant for the full toxin molecule. The antibodies used, AR4 and RAZ1, bind to nonoverlapping epitopes present on both the full toxin and on the recombinant fragment. In one format, the immunoassay is carried out in a 96-well plate with detection in a standard plate reader using AR4 as the capture antibody and QD-coupled RAZ1 as the reporter. Detection to 31 pM with a total incubation time of 3 hours was demonstrated. In a second format, the AR4 capture antibody was coupled to Sepharose beads, and the reactions were carried out in microcentrifuge tubes with an incubation time of 1 hour. The beads were subsequently captured and concentrated in a rotating rod “renewable surface” flow cell equipped with a fiber optic system for fluorescence measurements. In PBS buffer, the BoNT/A-HC-fragment was detected to concentrations as low as 5 pM using the fluidic measurement approach. PMID:19643593

  10. Immobilization of saccharides and peptides on 96-well microtiter plates coated with methyl vinyl ether-maleic anhydride copolymer.

    PubMed

    Satoh, A; Kojima, K; Koyama, T; Ogawa, H; Matsumoto, I

    1998-06-15

    We have previously reported a method to immobilize protein ligands on microtiter plates coated with methyl vinyl ether-maleic anhydride copolymer (MMAC) [Isosaki, K., et al. (1992) J. Chromatogr. 597, 123-128]. In this study, we improved the MMAC method to efficiently immobilize not only small ligands such as peptides and oligosaccharides, which could not be efficiently immobilized previously, but also heparin via its reducing end. Amino and hydrazino groups were introduced to MMAC-coated microtiter plate wells by coupling to acid anhydride groups of MMAC with 1,6-hexamethylenediamine and adipic acid dihydrazide, respectively. The amino groups introduced were allowed to react with peptides by use of divalent cross-linkers. Hydrazino groups were allowed to react with formyl groups of saccharides by reductive amination. Peptides and oligosaccharides were immobilized in a dose-dependent manner by these methods. In the case of the angiotensin peptide thus immobilized, the detection limit by monoclonal antibodies was as low as 0.1-1 fmol peptide per well. Application of 20-200 nmol oligosaccharides to the well was sufficient to immobilize and subsequently detect lectins. Furthermore, heparin immobilized on the hydrazinocoated wells was successfully used for the binding assay of annexin IV. PMID:9648659

  11. Identification of photosynthesis inhibitors of pelagic marine algae using 96-well plate microfractionation for enhanced throughput in effect-directed analysis.

    PubMed

    Booij, Petra; Vethaak, A Dick; Leonards, Pim E G; Sjollema, Sascha B; Kool, Jeroen; de Voogt, Pim; Lamoree, Marja H

    2014-07-15

    Because of large-scale production and use of an increasing diversity of chemicals in modern society, estuarine and coastal waters may be contaminated with numerous substances. Some of these compounds have the potential to affect microalgae at the base of the pelagic food chain. Therefore, we identified the main chemical stressors that negatively affect the effective photosystem II efficiency (ϕPSII) in marine microalgae of the Dutch estuarine and coastal waters. An enhanced effect-directed analysis (EDA) was carried out by combining reversed-phase ultra performance liquid chromatography fractionation of extracts from passive samplers, followed by effect assessment using the pulse amplitude modulation fluorometry assay and chemical analysis of biologically active fractions using high-resolution mass spectrometry. This study focuses on a novel microfractionation technique using 96-well plates to enhance throughput in EDA, structure elucidation, and the analytical and effect confirmation of the compounds that are identified. Although there are numerous unknown compounds present in estuarine and coastal waters, our EDA study shows that atrazine, diuron, irgarol, isoproturon, terbutryn, and terbutylazine are the main contributors to the observed effect on the ϕPSII of marine microalgae. PMID:24926900

  12. High throughput adjustable 96-well plate assay for androgen receptor binding: a practical approach for EDC screening using the chimpanzee AR.

    PubMed

    Hartig, P C; Cardon, M C; Blystone, C R; Gray, L E; Wilson, V S

    2008-09-26

    The issue as to whether natural and man-made chemicals interfere with endocrine function has raised concerns. This interference could be biologically significant even at very low doses if the chemicals interact deleteriously with hormone receptors at low concentrations. Therefore, the United States Environmental Protection Agency (USEPA) Office of Coordination and Policy (OSCP) requested that a nonhuman mammalian androgen receptor binding assay be developed for possible use in their Endocrine Disruptor Screening Program (EDSP). Ideally, this assay would be high throughput, not use animals as a source of receptor protein, easily deployed throughout the scientific community, utilize reagents available to both the public and private sector, and have the potential for future automation. We developed a highly modified 96-well plate assay which meets these criteria. It employs a baculovirus expressed recombinant primate androgen receptor which is publically available and exploits the unique ability of some mammalian androgen receptors to remain biologically active after guanidine hydrochloride (GdnHCl) solubilization. This GdnHCl treated receptor remains soluble and requires no additional purification prior to use. We provide a very detailed description of the assay protocol itself, and similarly detailed method for producing and solubilizing the receptor. PMID:18691642

  13. Development and application of a high-throughput sample cleanup process based on 96-well plate for simultaneous determination of 16 steroids in biological matrices using liquid chromatography-triple quadrupole mass spectrometry.

    PubMed

    Luo, Guanzhong; Li, Youxin; Bao, James J

    2016-02-01

    A novel high-throughput sample pretreatment system was developed by the integration of protein precipitation (PP), phospholipid removal (PPR), and hollow fiber liquid-phase microextraction (HF-LPME) into two simple 96-well plates and a matching 96-grid lid. With this system, 16 steroids were separated from biological matrices of plasma, milk, and urine and analyzed by liquid chromatography-triple quadrupole mass spectrometry. In the tandem sample cleanup process, the prepositive PP and PPR step preliminarily removed some of the interferences from the biological matrices. The following HF-LPME step kept the residual interference out of the hollow fiber and enriched the steroids in the hollow fiber to achieve high sensitivity. By a series of method optimizations, acetonitrile was chosen as the crash solvent for PP and PPR. A mixture of octanol and toluene (1:1 v/v) was used as the acceptor phase for HF-LPME. The extraction was conducted at 80 rpm for 50 min in a donor phase containing 1 mL 20% sodium chloride at 25 °C. Under these conditions, the limits of detection for the 16 steroids were 3.6-300.0 pg(.)mL(-1) in plasma, 3.0-270.0 pg·mL(-1) in milk, and 2.2-210.0 pg(.)mL(-1) in urine. The recoveries of the 16 steroids were 81.9-97.9% in plasma (relative standard deviation 1.0-8.0%), 80.6-97.7% in milk (relative standard deviation 0.8-5.4%), and 87.3-98.7% in urine (relative standard deviation 1.0-4.9%). Further, the integrated 96-well platform of PP, PPR, and HF-LPME enabled us to run this assay in an automatic and high-throughput fashion. The reliability of the method was further corroborated by evaluation of its applicability in plasma and urine samples from volunteers and fresh bovine milk from local dairy enterprises. PMID:26738495

  14. A novel colorimetric assay of β-D-glucans in basidiomycete strains by alcian blue dye in a 96-well microtiter plate.

    PubMed

    C Semedo, Magda; Karmali, Amin; Fonseca, Luís

    2015-01-01

    Basidiomycete strains synthesize several types of β-d-glucans, which play a major role in the medicinal properties of mushrooms. Therefore, the specific quantification of these β-d-glucans in mushroom strains is of great biochemical importance. Because published assay methods for these β-d-glucans present some disadvantages, a novel colorimetric assay method for β-d-glucan with alcian blue dye was developed. The complex formation was detected by following the decrease in absorbance in the range of 620 nm and by hypsochromic shift from 620 to 606 nm (∼14 nm) in UV-Vis spectrophotometer. Analysis of variance was used for optimization of the slope of the calibration curve by using the assay mixture containing 0.017% (w/v) alcian blue in 2% (v/v) acetic acid at pH 3.0. The high-throughput colorimetric assay method on microtiter plates was used for quantification of β-d-glucans in the range of 0-0.8 μg, with a slope of 44.15 × 10(-2) and a limit of detection of 0.017 μg/well. Recovery experiments were carried out by using a sample of Hericium erinaceus, which exhibited a recovery of 95.8% for β-1,3-d-glucan. The present assay method exhibited a 10-fold higher sensitivity and a 59-fold lower limit of detection compared with the published method with congo red. β-d-glucans of several mushrooms strains were isolated from fruiting bodies and mycelia, and they were quantified by this assay method. This assay method is fast, specific, simple, and it can be used to quantify β-d-glucans from other biological sources. PMID:26317582

  15. Location dependent biases in automatic 96-well microplate readers.

    PubMed

    Harrison, R O; Hammock, B D

    1988-01-01

    Procedures performed in 96-well microplates and quantitated by automatic readers assume instruments to be precise, accurate, and free of well location dependent bias. Instrument specifications generally focus on precision and accuracy without specifically addressing biases which are dependent on well location. These biases appear to be meniscus dependent and can be demonstrated in varying degrees in automatic readers of many designs by using a reverse plate wet test, which compares repeated readings of a dye loaded plate in normal and reversed positions. This test analyzes differences between readings and is, therefore, independent of pipetting error or other experimental variables such as protein binding or immunoassay variability. Different plates increased or decreased the magnitude of observed errors but did not themselves cause the errors measured by the reverse plate wet test. Error patterns were consistent for each reader and varied widely among the 16 instruments tested. Only 4 of 16 instruments passed an existing manufacturer's specification for precision, and only one of the 16 readers tested passed a similar specification for accuracy. The severest location dependent bias was found in an instrument which exhibited excellent repeatability and consistently passed its built-in diagnostic tests. One reader with significant bias was returned to the manufacturer for routine service and calibration, but it was not demonstrably improved. The reverse plate wet test is an extremely useful diagnostic tool for quality control at all stages of instrument manufacture and use. PMID:3069835

  16. Protocol: high throughput silica-based purification of RNA from Arabidopsis seedlings in a 96-well format

    PubMed Central

    2011-01-01

    The increasing popularity of systems-based approaches to plant research has resulted in a demand for high throughput (HTP) methods to be developed. RNA extraction from multiple samples in an experiment is a significant bottleneck in performing systems-level genomic studies. Therefore we have established a high throughput method of RNA extraction from Arabidopsis thaliana to facilitate gene expression studies in this widely used plant model. We present optimised manual and automated protocols for the extraction of total RNA from 9-day-old Arabidopsis seedlings in a 96 well plate format using silica membrane-based methodology. Consistent and reproducible yields of high quality RNA are isolated averaging 8.9 μg total RNA per sample (~20 mg plant tissue). The purified RNA is suitable for subsequent qPCR analysis of the expression of over 500 genes in triplicate from each sample. Using the automated procedure, 192 samples (2 × 96 well plates) can easily be fully processed (samples homogenised, RNA purified and quantified) in less than half a day. Additionally we demonstrate that plant samples can be stored in RNAlater at -20°C (but not 4°C) for 10 months prior to extraction with no significant effect on RNA yield or quality. Additionally, disrupted samples can be stored in the lysis buffer at -20°C for at least 6 months prior to completion of the extraction procedure providing a flexible sampling and storage scheme to facilitate complex time series experiments. PMID:22136293

  17. A microassay for measuring glycogen in 96-well-cultured cells.

    PubMed

    Gómez-Lechón, M J; Ponsoda, X; Castell, J V

    1996-05-01

    This study describes a rapid, sensitive, and automated spectrophotometric enzymatic microassay that measures the intracellular glycogen of primary cultured hepatocytes and other cultured cells in 96-well plates and can be adapted for other samples that are transferred to these plates. The procedure involves in situ disruption of cells, followed by hydrolysis of glycogen into glucosyl units by fungal glucoamylase (exo-1.4-alpha-glucosidase, EC 3.2.1.3), and glucose determination with the glucose oxidase colorimetric method. The color intensity can be measured in conventional ELISA readers, and the data can be fed to an on-line computer for rapid processing. The advantages of this method are its simplicity and automation, the reduction in sample handling, and the small number of cells required compared to other conventional methods. PMID:8660508

  18. Establishment and validation of a method for multi-dose irradiation of cells in 96-well microplates

    SciTech Connect

    Abatzoglou, Ioannis; Zois, Christos E.; Pouliliou, Stamatia

    2013-02-15

    Highlights: ► We established a method for multi-dose irradiation of cell cultures within a 96-well plate. ► Equations to adjust to preferable dose levels are produced and provided. ► Up to eight different dose levels can be tested in one microplate. ► This method results in fast and reliable estimation of radiation dose–response curves. -- Abstract: Microplates are useful tools in chemistry, biotechnology and molecular biology. In radiobiology research, these can be also applied to assess the effect of a certain radiation dose delivered to the whole microplate, to test radio-sensitivity, radio-sensitization or radio-protection. Whether different radiation doses can be accurately applied to a single 96-well plate to further facilitate and accelerated research by one hand and spare funds on the other, is a question dealt in the current paper. Following repeated ion-chamber, TLD and radiotherapy planning dosimetry we established a method for multi-dose irradiation of cell cultures within a 96-well plate, which allows an accurate delivery of desired doses in sequential columns of the microplate. Up to eight different dose levels can be tested in one microplate. This method results in fast and reliable estimation of radiation dose–response curves.

  19. High throughput preparation of fly genomic DNA in 96-well format using a paint-shaker.

    PubMed

    Lang, Michael; Nagy, Olga; Lang, Claus; Orgogozo, Virginie

    2015-01-01

    Sample homogenization is an essential step for genomic DNA extraction, with multiple downstream applications in Molecular Biology. Genotyping hundreds or thousands of samples requires an automation of this homogenization step, and high throughput homogenizer equipment currently costs 7000 euros or more. We present an apparatus for homogenization of individual Drosophila adult flies in 96-well micro-titer dishes, which was built from a small portable paint-shaker (F5 portable paint-shaker, Ushake). Single flies are disrupted in each well that contains extraction buffer and a 4-mm metal ball. Our apparatus can hold up to five 96-well micro-titer plates. Construction of the homogenizer apparatus takes about 3-4 days, and all equipment can be obtained from a home improvement store. The total material cost is approximately 700 euros including the paint-shaker. We tested the performance of our apparatus using the ZR-96 Quick-gDNA™ kit (Zymo Research) homogenization buffer and achieved nearly complete tissue homogenization after 15 minutes of shaking. PCR tests did not detect any cross contamination between samples of neighboring wells. We obtained on average 138 ng of genomic DNA per fly, and DNA quality was adequate for standard PCR applications. In principle, our tissue homogenizer can be used for isolation of DNA suitable for library production and high throughput genotyping by Multiplexed Shotgun Genotyping (MSG), as well as RNA isolation from single flies. The sample adapter can also hold and shake other items, such as centrifuge tubes (15-50 mL) or small bottles. PMID:26818699

  20. High throughput preparation of fly genomic DNA in 96-well format using a paint-shaker

    PubMed Central

    Lang, Michael; Nagy, Olga; Lang, Claus; Orgogozo, Virginie

    2015-01-01

    Sample homogenization is an essential step for genomic DNA extraction, with multiple downstream applications in Molecular Biology. Genotyping hundreds or thousands of samples requires an automation of this homogenization step, and high throughput homogenizer equipment currently costs 7000 euros or more. We present an apparatus for homogenization of individual Drosophila adult flies in 96-well micro-titer dishes, which was built from a small portable paint-shaker (F5 portable paint-shaker, Ushake). Single flies are disrupted in each well that contains extraction buffer and a 4-mm metal ball. Our apparatus can hold up to five 96-well micro-titer plates. Construction of the homogenizer apparatus takes about 3–4 days, and all equipment can be obtained from a home improvement store. The total material cost is approximately 700 euros including the paint-shaker. We tested the performance of our apparatus using the ZR-96 Quick-gDNA™ kit (Zymo Research) homogenization buffer and achieved nearly complete tissue homogenization after 15 minutes of shaking. PCR tests did not detect any cross contamination between samples of neighboring wells. We obtained on average 138 ng of genomic DNA per fly, and DNA quality was adequate for standard PCR applications. In principle, our tissue homogenizer can be used for isolation of DNA suitable for library production and high throughput genotyping by Multiplexed Shotgun Genotyping (MSG), as well as RNA isolation from single flies. The sample adapter can also hold and shake other items, such as centrifuge tubes (15–50 mL) or small bottles. PMID:26818699

  1. Development of a novel 96-well format for liquid-liquid microextraction and its application in the HPLC analysis of biological samples.

    PubMed

    Borijihan, Guirong; Li, Youxin; Gao, Jianguo; Bao, James J

    2014-05-01

    A novel 96-well liquid-liquid microextraction system combined with modern HPLC was developed and used for the simultaneous analysis of 96 biological samples. The system made use of hollow fibers, a 96-well plate, and a plastic base with a center hole and a side hole. One end of the hollow fiber was sealed, while the other end was attached to one of the holes positioned at the center for the plastic base. The needle was inserted into the liquid from inside or outside of the hollow fiber through the center or the side holes, respectively. The system was tested with plasma samples containing three compounds, acidic indomethacin, neutral dexamethasone, and basic propafenone. Some parameters, such as the kind and dimension of hollow fiber, pH and salt concentration of the donor phase, the selection of organic solvent for the acceptor phase, and the extraction time were investigated. Under the optimization conditions, the Log D and drug concentration of indomethacin, dexamethasone, and propafenone in plasma and urine samples were analyzed. Then, the methodology was validated. The results demonstrated that ng/mL levels could be exactly and rapidly analyzed by our system, which was equipped with an auto-injection sampler, making sample analysis more convenient. PMID:24574156

  2. Determining cereal starch amylose content using a dual wavelength iodine binding 96 well plate assay

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Cereal starch amylose/amylopectin (AM/AP) ratios are critical in functional properties for food and industrial applications. Conventional determination of AM/AP of cereal starches are very time consuming and labor intensive making it very difficult to screen large sample sets. Studying these large...

  3. Development of a 96-well plate iodine binding assay for amylose content determination

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Cereal starch amylose/amylopectin (AM/AP) ratios are critical in functional properties for food and industrial applications. Conventional methods for the determination of AM/AP of cereal starches are very time consuming and labor intensive making it very difficult to screen large sample sets. Stud...

  4. Folate content in fresh-cut vegetable packed products by 96-well microtiter plate microbiological assay.

    PubMed

    Fajardo, Violeta; Alonso-Aperte, Elena; Varela-Moreiras, Gregorio

    2015-02-15

    Ready-to-eat foods have nowadays become a significant portion of the diet. Accordingly, nutritional composition of these food categories should be well-known, in particular its folate content. However, there is a broad lack of folate data in food composition tables and databases. A total of 21 fresh-cut vegetable and fruit packed products were analysed for total folate (TF) content using a validated method that relies on the folate-dependent growth of chloramphenicol-resistant Lactobacillus casei subspecies rhamnosus (NCIMB 10463). Mean TF content ranged from 10.0 to 140.9μg/100g for the different matrices on a fresh weight basis. Higher TF quantity, 140.9-70.1μg/100g, was found in spinach, rocket, watercress, chard and broccoli. Significant differences were observed between available data for fresh vegetables and fruits from food composition tables or databases and the analysed results for fresh-cut packed products. Supplied data support the potential of folate-rich fresh-cut ready-to-eat vegetables to increase folate intake significantly. PMID:25236228

  5. HIGHLY SENSITIVE ASSAY FOR ANTICHOLINESTERASE COMPOUNDS USING 96 WELL PLATE FORMAT

    EPA Science Inventory

    One of the approaches for reducing uncertainties in the assessment of human exposure is to better characterize concentrations of hazardous compounds that may be present in our immediate environment. A significant limitation to this approach, however, is that sampling and labora...

  6. A 96-well electrochemical method for the screening of enzymatic activities.

    PubMed

    Abdellaoui, Sofiène; Noiriel, Alexandre; Henkens, Robert; Bonaventura, Celia; Blum, Loïc J; Doumèche, Bastien

    2013-04-01

    The rapid electrochemical screening of enzyme activities in bioelectronics is still a challenging issue. In order to solve this problem, we propose to use a 96-well electrochemical assay. This system is composed of 96 screen-printed electrodes on a printed circuit board adapted from a commercial system (carbon is used as the working electrode and silver chloride as the counter/reference electrode). The associated device allows for the measurements on the 96 electrodes to be performed within a few seconds. In this work, we demonstrate the validity of the screening method with the commercial laccase from the fungus Trametes versicolor. The signal-to-noise ratio (S/N) is found to be the best way to analyze the electrochemical signals. The S/N follows a saturation-like mechanism with a dynamic linear range of two decades ranging from 0.5 to 75 ng of laccase (corresponding to enzymatic activities from 62 × 10(-6) to 9.37 × 10(-3) μmol min(-1)) and a sensitivity of 3027 μg(-1) at +100 mV versus Ag/AgCl. Laccase inhibitors (azide and fluoride anions), pH optima, and interfering molecules could also be identified within a few minutes. PMID:23461701

  7. Practical automatic Arabic license plate recognition system

    NASA Astrophysics Data System (ADS)

    Mohammad, Khader; Agaian, Sos; Saleh, Hani

    2011-02-01

    Since 1970's, the need of an automatic license plate recognition system, sometimes referred as Automatic License Plate Recognition system, has been increasing. A license plate recognition system is an automatic system that is able to recognize a license plate number, extracted from image sensors. In specific, Automatic License Plate Recognition systems are being used in conjunction with various transportation systems in application areas such as law enforcement (e.g. speed limit enforcement) and commercial usages such as parking enforcement and automatic toll payment private and public entrances, border control, theft and vandalism control. Vehicle license plate recognition has been intensively studied in many countries. Due to the different types of license plates being used, the requirement of an automatic license plate recognition system is different for each country. [License plate detection using cluster run length smoothing algorithm ].Generally, an automatic license plate localization and recognition system is made up of three modules; license plate localization, character segmentation and optical character recognition modules. This paper presents an Arabic license plate recognition system that is insensitive to character size, font, shape and orientation with extremely high accuracy rate. The proposed system is based on a combination of enhancement, license plate localization, morphological processing, and feature vector extraction using the Haar transform. The performance of the system is fast due to classification of alphabet and numerals based on the license plate organization. Experimental results for license plates of two different Arab countries show an average of 99 % successful license plate localization and recognition in a total of more than 20 different images captured from a complex outdoor environment. The results run times takes less time compared to conventional and many states of art methods.

  8. Protein farnesyltransferase: measurement of enzymatic activity in 96-well format using TopCount microplate scintillation counting technology.

    PubMed

    Harwood, H J

    1995-04-10

    Protein farnesyltransferase (PFT) catalyzes the transfer of the farnesyl group of farnesyl pyrophosphate (FPP) to proteins ending with a carboxy-terminal CAAX motif, forming a thioether linkage to the cysteine residue of the protein. A method is described herein for measurement of PFT activity in 96-well format using TopCount microplate scintillation counting technology. This method has the advantages of requiring only a single transfer from reaction vessels or wells of a 96-well reaction plate to the filtration wells of a 96-well Packard UniFilter GF/B filtration plate following acid precipitation and of allowing liquid scintillation counting to be conducted directly in the filtration plate without the need for either removal of the filter from the plate or transfer of the filter to liquid scintillation vials prior to radioactivity assessment. Using rat brain cytosol as the source of PFT, H-ras as the source of farnesyl acceptor protein, and [1-3H]FPP as the farnesyl donor, the incorporation of radiolabeled farnesyl residues into H-ras was found to be a linear function of both the time of incubation at 37 degrees C (up to 75 min) and the concentration of rat brain cytosolic protein present during incubation (up to 40 micrograms protein), and to be dependent on the concentration of H-ras (Km = 1.1 microM) and FPP (Km = 0.6 microM) present in the incubation reaction. In the presence of 4 microM H-ras, 0.5 microM FPP, 4 mM MgCl2, and 20 microM ZnCl2, the specific activity of rat brain cytosolic PFT measured using this methodology was 0.253 +/- 0.036 (SD; n = 30) pmol H-ras farnesylated per minute of incubation at 37 degrees C per milligram cytosolic protein. The signal-to-noise ratio for H-ras farnesylation using this methodology averaged 25 relative to incubation in the absence of H-ras (background farnesylation of cytosolic proteins) and 50 relative to incubation in the absence of both H-ras and rat brain cytosol (background filter associated radioactivity

  9. 96-well format-based microfluidic platform for parallel interconnection of multiple multicellular spheroids.

    PubMed

    Kim, Jin-Young; Fluri, David A; Kelm, Jens M; Hierlemann, Andreas; Frey, Olivier

    2015-06-01

    In this article, we present a microfluidic platform, compatible with conventional 96-well formats, that enables facile and parallelized culturing and testing of spherical microtissues in a standard incubator. The platform can accommodate multiple microtissues (up to 66) of different cell types, formed externally by using the hanging-drop method, and enables microtissue interconnection through microfluidic channels for continuous media perfusion or dosage of substances. The platform contains 11 separate channels, and each channel has six tissue compartments. Primary rat liver tissues were cultured over 8 days, and multiple tumor tissues (HCT116) were exposed to various concentrations of 5-fluorouracil for platform characterization. PMID:25524491

  10. Lighting system with heat distribution face plate

    DOEpatents

    Arik, Mehmet; Weaver, Stanton Earl; Stecher, Thomas Elliot; Kuenzler, Glenn Howard; Wolfe, Jr., Charles Franklin; Li, Ri

    2013-09-10

    Lighting systems having a light source and a thermal management system are provided. The thermal management system includes synthetic jet devices, a heat sink and a heat distribution face plate. The synthetic jet devices are arranged in parallel to one and other and are configured to actively cool the lighting system. The heat distribution face plate is configured to radially transfer heat from the light source into the ambient air.

  11. A novel 96-well gel-based assay for determining antifungal activity against filamentous fungi.

    PubMed

    Troskie, Anscha Mari; Vlok, Nicolas Maré; Rautenbach, Marina

    2012-12-01

    In recent years the global rise in antibiotic resistance and environmental consciousness lead to a renewed fervour to find and develop novel antibiotics, including antifungals. However, the influence of the environment on antifungal activity is often disregarded and many in vitro assays may cause the activity of certain antifungals to be overestimated or underestimated. The general antifungal test assays that are economically accessible to the majority of scientists primarily rely on visual examination or on spectrophotometric analysis. The effect of certain morphogenic antifungals, which may lead to hyperbranching of filamentous fungi, unfortunately renders these methods unreliable. To minimise the difficulties experienced as a result of hyperbranching, we developed a straightforward, economical 96-well gel-based method, independent of spectrophotometric analysis, for highly repeatable determination of antifungal activity. For the calculation of inhibition parameters, this method relies on the visualisation of assay results by digitisation. The antifungal activity results from our novel micro-gel dilution assay are comparable to that of the micro-broth dilution assay used as standard reference test of The Clinical and Laboratory Standard Institute. Furthermore, our economical assay is multifunctional as it permits microscopic analysis of the preserved assay results, as well as rendering highly reliable data. PMID:23089670

  12. Parallel Plate System for Collecting Data Used to Determine Viscosity

    NASA Technical Reports Server (NTRS)

    Kaukler, William (Inventor); Ethridge, Edwin C. (Inventor)

    2013-01-01

    A parallel-plate system collects data used to determine viscosity. A first plate is coupled to a translator so that the first plate can be moved along a first direction. A second plate has a pendulum device coupled thereto such that the second plate is suspended above and parallel to the first plate. The pendulum device constrains movement of the second plate to a second direction that is aligned with the first direction and is substantially parallel thereto. A force measuring device is coupled to the second plate for measuring force along the second direction caused by movement of the second plate.

  13. A Measurement System for Spectrographic Plates

    NASA Astrophysics Data System (ADS)

    Nylén, Per

    1982-02-01

    An analysis system for measurement and data processing of spectra, recorded on spectrographic plates, is described. The system uses diode arrays for line profile scanning and a television camera for survey. The positions are measured using a Heidenhain equipment, and a micro-computer guides and controls the system. The computer is programmed to support the operator with utility routines for data collection and processing and for operator guidance.

  14. Root-Contact/Pressure-Plate Assembly For Hydroponic System

    NASA Technical Reports Server (NTRS)

    Morris, Carlton E.; Loretan, Philip A.; Bonsi, Conrad K.; Hill, Walter A.

    1994-01-01

    Hydroponic system includes growth channels equipped with rootcontact/pressure-plate assemblies. Pump and associated plumbing circulate nutrient liquid from reservoir, along bottom of growth channels, and back to reservoir. Root-contact/pressure-plate assembly in each growth channel stimulates growth of roots by applying mild contact pressure. Flat plate and plate connectors, together constitute pressure plate, free to move upward to accommodate growth of roots. System used for growing sweetpotatoes and possibly other tuber and root crops.

  15. Electronic readout systems for microchannel plates

    NASA Technical Reports Server (NTRS)

    Timothy, J. G.

    1985-01-01

    The modes of operation of position-sensitive electronic readout systems which use high-gain microchannel plate (MCP) electron multipliers are described, and their performance characteristics, along with those of the MCP, are compared. Among the structures presented are the wedge-and-strip, Codacon, and multilayer coincidence-anode MAMA (Multimode Microchannel Array) arrays. Spatial resolution of 25 x 25 sq microns (coincidence anode arrays) is achieved with an array format of 256 x 1024 pixels. On the basis of the performance data it is concluded that the readout systems using only conducting electrodes offer the best performance characteristics.

  16. Turbidimetric assay for tetracyclines in feeds using a microtiter plate system.

    PubMed

    Brady, M S; Katz, S E

    1991-01-01

    The microtiter plate system for turbidimetric assay of chlortetracycline (CTC) and oxytetracycline (OTC) levels in feeds uses a 96 well microtiter plate, a multichannel pipette, and an ELISA reader to measure turbidity. Feeds are extracted for both tetracyclines using AOAC extraction systems. For CTC, the range of the standard curve is 0.001-0.005 microgram CTC/mL; for OTC, the range is 0.004-0.016 microgram OTC/mL. Repeatability of CTC assays, as shown by the coefficient of variation (CV), ranged from 0.54 to 5.65% for same-day assays and from 2.01 to 9.39% for assays on different days. For OTC, CVs ranged from 2.69 to 10.01% for same-day assays and 3.24 to 9.08% for different-day assays. Average recoveries for CTC were 108.7% for same-day assays and 106.8% for different-day assays; for OTC, average recoveries were 112.4% and 106.5% for same-day and different-day assays, respectively. PMID:1874689

  17. Numerically simulating the sandwich plate system structures

    NASA Astrophysics Data System (ADS)

    Feng, Guo-Qing; Li, Gang; Liu, Zhi-Hui; Niu, Huai-Lei; Li, Chen-Feng

    2010-09-01

    Sandwich plate systems (SPS) are advanced materials that have begun to receive extensive attention in naval architecture and ocean engineering. At present, according to the rules of classification societies, a mixture of shell and solid elements are required to simulate an SPS. Based on the principle of stiffness decomposition, a new numerical simulation method for shell elements was proposed. In accordance with the principle of stiffness decomposition, the total stiffness can be decomposed into the bending stiffness and shear stiffness. Displacement and stress response related to bending stiffness was calculated with the laminated shell element. Displacement and stress response due to shear was calculated by use of a computational code write by FORTRAN language. Then the total displacement and stress response for the SPS was obtained by adding together these two parts of total displacement and stress. Finally, a rectangular SPS plate and a double-bottom structure were used for a simulation. The results show that the deflection simulated by the elements proposed in the paper is larger than the same simulated by solid elements and the analytical solution according to Hoff theory and approximate to the same simulated by the mixture of shell-solid elements, and the stress simulated by the elements proposed in the paper is approximate to the other simulating methods. So compared with calculations based on a mixture of shell and solid elements, the numerical simulation method given in the paper is more efficient and easier to do.

  18. Composite Bipolar Plate for Unitized Fuel Cell/Electrolyzer Systems

    NASA Technical Reports Server (NTRS)

    Mittelsteadt, Cortney K.; Braff, William

    2009-01-01

    In a substantial improvement over present alkaline systems, an advanced hybrid bipolar plate for a unitized fuel cell/electrolyzer has been developed. This design, which operates on pure feed streams (H2/O2 and water, respectively) consists of a porous metallic foil filled with a polymer that has very high water transport properties. Combined with a second metallic plate, the pore-filled metallic plates form a bipolar plate with an empty cavity in the center.

  19. Single-step method for β-galactosidase assays in Escherichia coli using a 96-well microplate reader.

    PubMed

    Schaefer, Jorrit; Jovanovic, Goran; Kotta-Loizou, Ioly; Buck, Martin

    2016-06-15

    Historically, the lacZ gene is one of the most universally used reporters of gene expression in molecular biology. Its activity can be quantified using an artificial substrate, o-nitrophenyl-ß-d-galactopyranoside (ONPG). However, the traditional method for measuring LacZ activity (first described by J. H. Miller in 1972) can be challenging for a large number of samples, is prone to variability, and involves hazardous compounds for lysis (e.g., chloroform, toluene). Here we describe a single-step assay using a 96-well microplate reader with a proven alternative cell permeabilization method. This modified protocol reduces handling time by 90%. PMID:27036618

  20. Single-step method for β-galactosidase assays in Escherichia coli using a 96-well microplate reader

    PubMed Central

    Schaefer, Jorrit; Jovanovic, Goran; Kotta-Loizou, Ioly; Buck, Martin

    2016-01-01

    Historically, the lacZ gene is one of the most universally used reporters of gene expression in molecular biology. Its activity can be quantified using an artificial substrate, o-nitrophenyl-ß-d-galactopyranoside (ONPG). However, the traditional method for measuring LacZ activity (first described by J. H. Miller in 1972) can be challenging for a large number of samples, is prone to variability, and involves hazardous compounds for lysis (e.g., chloroform, toluene). Here we describe a single-step assay using a 96-well microplate reader with a proven alternative cell permeabilization method. This modified protocol reduces handling time by 90%. PMID:27036618

  1. Calibration of Micro Channel Plate Detector Systems

    NASA Astrophysics Data System (ADS)

    Dekat, S.; Kypreos, T.; Moore, J.; Gay, D.; Wiedenhoever, I.

    2004-10-01

    Two position-sensitive micro-channel plate (MCP) detector systems have been assembled and tested at the University of North Florida. These detectors track heavy-ions in Florida State University's radioactive beam facility, RESOLUT. Plans for the systems were supplied by C. J. Gross and D. Shapira of ORNL. Each system consists of an aluminized 0.9-micron Mylar foil facing a 40-mm diameter MCP sensor head with a resistive anode encoder (RAE). Delta electrons emitted as a heavy ion passes through the foil are accelerated toward the sensor head by an electric field. The divergence of the electrons is limited by a magnetic field from a NdFeB magnet which is coaxial with and behind the sensor head. A digital oscilloscope has been programmed to convert amplified and shaped pulses from the RAE into position coordinates. Calibration experiments were performed with the foil replaced by an aluminum grid of 1 mm wide strips. Using alpha particles from a ^241Am source incident on the grid, optimum operating parameters were established by resolving aluminum strips separated by 1 mm.

  2. Fast carbohydrate analysis via liquid chromatography coupled with ultra violet and electrospray ionization ion trap detection in 96-well format.

    PubMed

    Rühmann, Broder; Schmid, Jochen; Sieber, Volker

    2014-07-11

    A fast carbohydrate screening platform processible in 96-well format is described. The method is suitable for the determination of various carbohydrates out of complex mixtures as obtained by acidic hydrolysis of carbohydrates polymers. The chromatographic conditions for an efficient separation (12min) and the derivatization process with 1-phenyl-3-methyl-5-pyrazolone (PMP) were optimized for high resolution separation and simultaneous determination of deoxy-, amino-, anhydro-sugars as well as hexoses, pentoses, dimers, uronic acids and degradation products like furfural and hydroxymethylfurfural (HMF). The potential to quantify with UV- and MS-detector in the same range has been demonstrated for 20 different compounds. Finally, the matrix effects of the hydrolysis were positively evaluated. The micro scale hydrolysis and PMP-derivatization without any extraction or drying steps, both in 96-well format, result in a fast and intuitive sample preparation. In combination with a fast liquid chromatography coupled to UV and electrospray ionization ion trap detection (LC-UV-ESI-MS/MS) for the qualification and quantification of various sugars, dimers and degradation products, this method shows great performance in carbohydrate analysis. PMID:24861788

  3. Orion Boiler Plate Airdrop Test System

    NASA Technical Reports Server (NTRS)

    Machin, Ricardo A.; Evans, Carol T.

    2013-01-01

    On the 29th of February 2012 the Orion Capsule Parachute Assembly System (CPAS) project attempted to perform an airdrop test of a boilerplate test article for the second time. The first attempt (Cluster Development Test 2, July 2008) to deliver a similar boilerplate from a C-17 using the Low Velocity Air Drop (LVAD) technique resulted in the programmer parachute failing to properly inflate, the test article failing to achieve the desired test initiation conditions, and the test article a total loss. This paper will pick up where the CDT-2 failure investigation left off, describing the test technique that was adopted, and outline the modeling that was performed to gain confidence that the second attempt would be successful. The second boiler plate test (Cluster Development Test 3-3) was indeed a complete success and has subsequently been repeated several times, allowing the CPAS project to proceed with the full scale system level development testing required to integrate the hardware to the first Entry Flight Test vehicle as well as go into the Critical Design Review with minimum risk and a mature design.

  4. Performance of the PBX-M passive plate stabilization system

    SciTech Connect

    Kugel, H.W.; Bell, R.; Bernabei, S.

    1994-02-01

    The PBX-M passive plate stabilization system provides significant stabilization of long-wavelength external kink modes, the slowing of vertical instability growth rates, and the amelioration of disruption characteristics. The passive plate stabilization system has allowed the use of LHCD and IBW to induce current density and pressure profile modifications, and m = 1 divertor biasing for modifying edge plasma transport. Improvements in the passive plate system insulators and support structures have provided reliable operation. Impurity influxes with the close-fitting passive plates are low. Solid target boronization is applied routinely to reduce conditioning time and maintain clean conditions.

  5. Plate Tectonics, Geographical Information System, paleogeography

    SciTech Connect

    Moore, Thomas L.; Scotese, Christopher

    2002-05-24

    The PaleoX.framwork is a dynamically linked/loaded framework for Cocoa applications. The primary goal of this library is to standardize several elements used for working with paleogeographic data. This includes objects designed to organize information for tectonic plates, including maps, rotation objects, plate names, and designations. In addition, PaleoX provides object-oriented solutions for handling standard paleogeographic file formats from the PALEOMAP Project.

  6. Characterization of multiple platelet activation pathways in patients with bleeding as a high-throughput screening option: use of 96-well Optimul assay

    PubMed Central

    Lordkipanidzé, Marie; Lowe, Gillian C.; Kirkby, Nicholas S.; Chan, Melissa V.; Lundberg, Martina H.; Morgan, Neil V.; Bem, Danai; Nisar, Shaista P.; Leo, Vincenzo C.; Jones, Matthew L.; Mundell, Stuart J.; Daly, Martina E.; Mumford, Andrew D.; Warner, Timothy D.; Watson, Steve P.; Watson, Steve P.; Mumford, Andrew D.; Mundell, Stuart J.; Gissen, Paul; Daly, Martina E.; Lester, Will; Clark, Justin; Williams, Mike; Motwani, Jayashree; Marshall, Dianne; Nyatanga, Priscilla; Mann, Pat; Kirwan, Julie; Wilde, Jonathan; Dunkley, Tracey; Greenway, April; Makris, Michael; Pavord, Sue; Dattani, Rashesh; Grimley, Gerry Dolan Charlotte; Stokley, Simone; Astwood, Emma; Chang, Cherry; Foros, Merri; Trower, Linda; Thachil, Jecko; Hay, Charlie; Pike, Gill; Will, Andrew; Grainger, John; Foulkes, Matt; Fareh, Mona; Talks, Kate; Biss, Tina; Kesteven, Patrick; Hanley, John; Vowles, Julie; Basey, Lesley; Barnes, Michelle; Collins, Peter; Rayment, Rachel; Alikhan, Raza; Morris, Ana Guerrero Rebecca; Mansell, Dianne; Toh, Cheng Hock; Martlew, Vanessa; Murphy, Elaine; Lachmann, Robin; Rose, Peter; Chapman, Oliver; Lokare, Anand; Marshall, Kathryn; Khan, Naseem; Keeling, David; Giangrande, Paul; Austin, Steve; Bevan, David; Alamelu, Jayanthi

    2014-01-01

    Up to 1% of the population have mild bleeding disorders, but these remain poorly characterized, particularly with regard to the roles of platelets. We have compared the usefulness of Optimul, a 96-well plate-based assay of 7 distinct pathways of platelet activation to characterize inherited platelet defects in comparison with light transmission aggregometry (LTA). Using Optimul and LTA, concentration-response curves were generated for arachidonic acid, ADP, collagen, epinephrine, Thrombin receptor activating-peptide, U46619, and ristocetin in samples from (1) healthy volunteers (n = 50), (2) healthy volunteers treated with antiplatelet agents in vitro (n = 10), and (3) patients with bleeding of unknown origin (n = 65). The assays gave concordant results in 82% of cases (κ = 0.62, P < .0001). Normal platelet function results were particularly predictive (sensitivity, 94%; negative predictive value, 91%), whereas a positive result was not always substantiated by LTA (specificity, 67%; positive predictive value, 77%). The Optimul assay was significantly more sensitive at characterizing defects in the thromboxane pathway, which presented with normal responses with LTA. The Optimul assay is sensitive to mild platelet defects, could be used as a rapid screening assay in patients presenting with bleeding symptoms, and detects changes in platelet function more readily than LTA. This trial was registered at www.isrctn.org as #ISRCTN 77951167. PMID:24408324

  7. Characterization of multiple platelet activation pathways in patients with bleeding as a high-throughput screening option: use of 96-well Optimul assay.

    PubMed

    Lordkipanidzé, Marie; Lowe, Gillian C; Kirkby, Nicholas S; Chan, Melissa V; Lundberg, Martina H; Morgan, Neil V; Bem, Danai; Nisar, Shaista P; Leo, Vincenzo C; Jones, Matthew L; Mundell, Stuart J; Daly, Martina E; Mumford, Andrew D; Warner, Timothy D; Watson, Steve P

    2014-02-20

    Up to 1% of the population have mild bleeding disorders, but these remain poorly characterized, particularly with regard to the roles of platelets. We have compared the usefulness of Optimul, a 96-well plate-based assay of 7 distinct pathways of platelet activation to characterize inherited platelet defects in comparison with light transmission aggregometry (LTA). Using Optimul and LTA, concentration-response curves were generated for arachidonic acid, ADP, collagen, epinephrine, Thrombin receptor activating-peptide, U46619, and ristocetin in samples from (1) healthy volunteers (n = 50), (2) healthy volunteers treated with antiplatelet agents in vitro (n = 10), and (3) patients with bleeding of unknown origin (n = 65). The assays gave concordant results in 82% of cases (κ = 0.62, P < .0001). Normal platelet function results were particularly predictive (sensitivity, 94%; negative predictive value, 91%), whereas a positive result was not always substantiated by LTA (specificity, 67%; positive predictive value, 77%). The Optimul assay was significantly more sensitive at characterizing defects in the thromboxane pathway, which presented with normal responses with LTA. The Optimul assay is sensitive to mild platelet defects, could be used as a rapid screening assay in patients presenting with bleeding symptoms, and detects changes in platelet function more readily than LTA. This trial was registered at www.isrctn.org as #ISRCTN 77951167. PMID:24408324

  8. Recent movements of the Juan de Fuca Plate System

    NASA Astrophysics Data System (ADS)

    1984-08-01

    Analysis of the magnetic anomalies of the Juan de Fuca plate system allows instantaneous poles of rotation relative to the Pacific plate to be calculated from 7 Ma to the present. By combining these with global solutions for Pacific America and ``absolute'' (relative to hot spot) motions, a plate motion sequence can be constructed. This sequence shows that both absolute motions and motions relative to America are characterized by slower velocities where younger and more buoyant material enters the convergence zone: ``pivoting subduction.'' The resistance provided by the youngest portion of the Juan de Fuca plate apparently resulted in its detachment at 4 Ma as the independent Explorer plate. In relation to the hot spot framework, this plate almost immediately began to rotate clockwise around a pole close to itself such that its translational movement into the mantle virtually ceased. After 4 Ma the remainder of the Juan de Fuca plate adjusted its motion in response to the fact that the youngest material entering the subduction zone was not to the south. Differences in seismicity and recent uplift between northern and southern Vancourver Island may reflect a distinction in tectonic style between the ``normal'' subduction of the Juan de Fuca plate to the south and a complex ``underplating occurring as the Explorer plate is overridden by the continent. The history of the Explorer plate may exemplify the conditins under which the self-driving forces of small subducting plates are overcome by the influence of larger, adjacent plates. The recent rapid migration of the absolute pole of rotation of the Juan de Fuca plate toward the plate suggests that it, too, may be nearing this condition.

  9. Recent movements of the Juan de Fuca Plate System

    NASA Astrophysics Data System (ADS)

    Riddihough, Robin

    1984-08-01

    Analysis of the magnetic anomalies of the Juan de Fuca plate system allows instantaneous poles of rotation relative to the Pacific plate to be calculated from 7 Ma to the present. By combining these with global solutions for Pacific/America and "absolute" (relative to hot spot) motions, a plate motion sequence can be constructed. This sequence shows that both absolute motions and motions relative to America are characterized by slower velocities where younger and more buoyant material enters the convergence zone: "pivoting subduction." The resistance provided by the youngest portion of the Juan de Fuca plate apparently resulted in its detachment at 4 Ma as the independent Explorer plate. In relation to the hot spot framework, this plate almost immediately began to rotate clockwise around a pole close to itself such that its translational movement into the mantle virtually ceased. After 4 Ma the remainder of the Juan de Fuca plate adjusted its motion in response to the fact that the youngest material entering the subduction zone was now to the south. Differences in seismicity and recent uplift between northern and southern Vancouver Island may reflect a distinction in tectonic style between the "normal" subduction of the Juan de Fuca plate to the south and a complex "underplating" occurring as the Explorer plate is overridden by the continent. The history of the Explorer plate may exemplify the conditions under which the self-driving forces of small subducting plates are overcome by the influence of larger, adjacent plates. The recent rapid migration of the absolute pole of rotation of the Juan de Fuca plate toward the plate suggests that it, too, may be nearing this condition.

  10. Development and validation of a 96-well cellular assay for the discovery of ALDH1A1 inhibitors.

    PubMed

    Ming, Wenyu; Ma, Wenzhen; Chen, Lisa H; Volk, Catherine; Michael, Mervyn Dodson; Xu, Yanping; Zhang, Fang; Wang, Xiaojun

    2013-07-01

    Retinoic acid, the active metabolite of vitamin A, plays important roles in various physiological and pathological processes. The two-step production of retinoic acid from vitamin A (retinol) is catalyzed by alcohol dehydrogenases and aldehyde dehydrogenases, which are potential therapeutic targets for numerous diseases, such as obesity, diabetes, and cancer. Currently, the lack of a suitable high-throughput cellular assay hinders efforts to identify therapeutic small molecular inhibitors of aldehyde dehydrogenase, such as ALDH1A1. In this report, we utilized high-content imaging technology and a commercially available cell permeable ALDH substrate to develop a 96-well cellular ALDH1A1 assay. This assay has a robust and sensitive readout and is amenable to automation. With this cellular assay, we identified potent selective ALDH1A1 inhibitors to explore the role of retinoic acid production in various preclinical disease models. PMID:23957476

  11. Note: Heated flyer-plate impact system.

    PubMed

    Dolan, D H; Seagle, C T; Ao, T; Hacking, R G

    2014-07-01

    A technique for launching heated flyer plates was developed on a single-stage gas gun. This type of impact creates a well-posed mechanical state and a tunable thermal state, which is useful for calibrating dynamic temperature measurements. Proof-of-principle thermoreflectance measurements were performed using this technique. Since the target remains at room temperature until the moment of impact, heated flyers avoid differential expansion and annealing issues, allowing novel impact experiments to be performed. PMID:25085187

  12. The BUME method: a novel automated chloroform-free 96-well total lipid extraction method for blood plasma[S

    PubMed Central

    Löfgren, Lars; Ståhlman, Marcus; Forsberg, Gun-Britt; Saarinen, Sinikka; Nilsson, Ralf; Hansson, Göran I.

    2012-01-01

    Lipid extraction from biological samples is a critical and often tedious preanalytical step in lipid research. Primarily on the basis of automation criteria, we have developed the BUME method, a novel chloroform-free total lipid extraction method for blood plasma compatible with standard 96-well robots. In only 60 min, 96 samples can be automatically extracted with lipid profiles of commonly analyzed lipid classes almost identically and with absolute recoveries similar or better to what is obtained using the chloroform-based reference method. Lipid recoveries were linear from 10–100 µl plasma for all investigated lipids using the developed extraction protocol. The BUME protocol includes an initial one-phase extraction of plasma into 300 µl butanol:methanol (BUME) mixture (3:1) followed by two-phase extraction into 300 µl heptane:ethyl acetate (3:1) using 300 µl 1% acetic acid as buffer. The lipids investigated included the most abundant plasma lipid classes (e.g., cholesterol ester, free cholesterol, triacylglycerol, phosphatidylcholine, and sphingomyelin) as well as less abundant but biologically important lipid classes, including ceramide, diacylglycerol, and lyso-phospholipids. This novel method has been successfully implemented in our laboratory and is now used daily. We conclude that the fully automated, high-throughput BUME method can replace chloroform-based methods, saving both human and environmental resources. PMID:22645248

  13. Biomechanical study comparing a new combined rod-plate system with conventional dual-rod and plate systems.

    PubMed

    Sha, Mo; Ding, Zheng-Qi; Ting, Hu S; Kang, Liang-Qi; Zhai, Wen-Liang; Liu, Hui

    2013-02-01

    Most anterior spinal instrumentation systems are designed as either a plate or dual-rod system and have corresponding limitations. Dual-rod designs may offer greater adjustability; however, this system also maintains a high profile and lacks a locking design. Plate systems are designed to be stiffer, but the fixed configuration is not adaptable to the variety of vertebral body shapes. The authors designed a new combined rod-plate system (D-rod) to overcome these limitations and compared its biomechanical performance with the conventional dual-rod and plate system. Eighteen pig spinal specimens were divided into 3 groups (6 per group). An L1 corpectomy was performed and fixed with the D-rod (group A; n=6), Z-plate (Sofamor Danek, Memphis, Tennessee) (group B; n=6), or Ventrofix (Synthes, Paoli, Pennsylvania) (group C; n=6) system. T13-L2 range of motion was measured with a 6 degrees of freedom (ie, flexion-extension, lateral bending, and axial rotation) spine simulator under pure moments of 6.0 Nm. The D-rod and Ventrofix specimens were significantly stiffer than the Z-plate specimens (P<.05) based on results obtained from lateral bending and flexion-extension tests. The D-rod and Z-plate specimens were significantly stiffer than the Ventrofix specimens (P<.05) in axial rotation. The D-rod combines the advantages of the plate and dual-rod systems, where the anterior rod exhibits the design of a low-profile locking plate, enhanced stability, and decreased interference of the surrounding vasculature. The posterior rods function in compression and distraction, and the dual-rod system offers greater adjustability and control over screw placement. The results indicate that it may provide adequate stability for anterior thoracolumbar reconstruction. PMID:23383624

  14. Determination of suvorexant in human plasma using 96-well liquid-liquid extraction and HPLC with tandem mass spectrometric detection.

    PubMed

    Breidinger, S A; Simpson, R C; Mangin, E; Woolf, E J

    2015-10-01

    A method, using liquid chromatography with tandem mass spectrometric detection (LC-MS/MS), was developed for the determination of suvorexant (MK-4305, Belsomra(®)), a selective dual orexin receptor antagonist for the treatment insomnia, in human plasma over the concentration range of 1-1000ng/mL. Stable isotope labeled (13)C(2)H3-suvorexant was used as an internal standard. The sample preparation procedure utilized liquid-liquid extraction, in the 96-well format, of a 100μL plasma sample with methyl t-butyl ether. The compounds were chromatographed under isocratic conditions on a Waters dC18 (50×2.1mm, 3μm) column with a mobile phase consisting of 30/70 (v/v %) 10mM ammonium formate, pH3/acetonitrile at a flow rate of 0.3mL/min. Multiple reaction monitoring of the precursor-to-product ion pairs for suvorexant (m/z 451→186) and (13)C(2)H3-suvorexant (m/z 455→190) on an Applied Biosystems API 4000 tandem mass spectrometer was used for quantitation. Intraday assay precision, assessed in six different lots of control plasma, was within 10% CV at all concentrations, while assay accuracy ranged from 95.6 to 105.0% of nominal. Quality control (QC) samples in plasma were stored at -20°C. Initial within day analysis of QCs after one freeze-thaw cycle showed accuracy within 9.5% of nominal with precision (CV) of 6.7% or less. The plasma QC samples were demonstrated to be stable for up to 25 months at -20°C. The method described has been used to support clinical studies during Phase I through III of clinical development. PMID:26343269

  15. Global Plate Velocities from the Global Positioning System

    NASA Technical Reports Server (NTRS)

    Larson, Kristine M.; Freymueller, Jeffrey T.; Philipsen, Steven

    1997-01-01

    We have analyzed 204 days of Global Positioning System (GPS) data from the global GPS network spanning January 1991 through March 1996. On the basis of these GPS coordinate solutions, we have estimated velocities for 38 sites, mostly located on the interiors of the Africa, Antarctica, Australia, Eurasia, Nazca, North America, Pacific, and South America plates. The uncertainties of the horizontal velocity components range from 1.2 to 5.0 mm/yr. With the exception of sites on the Pacific and Nazca plates, the GPS velocities agree with absolute plate model predictions within 95% confidence. For most of the sites in North America, Antarctica, and Eurasia, the agreement is better than 2 mm/yr. We find no persuasive evidence for significant vertical motions (less than 3 standard deviations), except at four sites. Three of these four were sites constrained to geodetic reference frame velocities. The GPS velocities were then used to estimate angular velocities for eight tectonic plates. Absolute angular velocities derived from the GPS data agree with the no net rotation (NNR) NUVEL-1A model within 95% confidence except for the Pacific plate. Our pole of rotation for the Pacific plate lies 11.5 deg west of the NNR NUVEL-1A pole, with an angular speed 10% faster. Our relative angular velocities agree with NUVEL-1A except for some involving the Pacific plate. While our Pacific-North America angular velocity differs significantly from NUVEL-1A, our model and NUVEL-1A predict very small differences in relative motion along the Pacific-North America plate boundary itself. Our Pacific-Australia and Pacific- Eurasia angular velocities are significantly faster than NUVEL-1A, predicting more rapid convergence at these two plate boundaries. Along the East Pacific Pise, our Pacific-Nazca angular velocity agrees in both rate and azimuth with NUVFL-1A.

  16. High resolution Fresnel zone plate laser alignment system

    SciTech Connect

    Bressler, V.E.; Fischer, G.E.; Ruland, R.E.; Wang, T.

    1992-03-01

    The existing Fresnel zone plate laser alignment system is currently being extended and upgraded for the Final Focus Test Beam (FFTB). Previously, the resolution of this system has been several tens of micrometers. After the upgrade, the resolution will be a few micrometers. Details of the upgrade as well as simulation and experimental results will be presented.

  17. Multiwell cell culture plate format with integrated microfluidic perfusion system

    NASA Astrophysics Data System (ADS)

    Domansky, Karel; Inman, Walker; Serdy, Jim; Griffith, Linda G.

    2006-01-01

    A new cell culture analog has been developed. It is based on the standard multiwell cell culture plate format but it provides perfused three-dimensional cell culture capability. The new capability is achieved by integrating microfluidic valves and pumps into the plate. The system provides a means to conduct high throughput assays for target validation and predictive toxicology in the drug discovery and development process. It can be also used for evaluation of long-term exposure to drugs or environmental agents or as a model to study viral hepatitis, cancer metastasis, and other diseases and pathological conditions.

  18. Study of plate-fin heat exchanger and cold plate for the active thermal control system of Space Station

    NASA Technical Reports Server (NTRS)

    Chyu, MING-C.

    1992-01-01

    Plate-fin heat exchangers will be employed in the Active Thermal Control System of Space Station Freedom. During ground testing of prototypic heat exchangers, certain anomalous behaviors have been observed. Diagnosis has been conducted to determine the cause of the observed behaviors, including a scrutiny of temperature, pressure, and flow rate test data, and verification calculations based on such data and more data collected during the ambient and thermal/vacuum tests participated by the author. The test data of a plate-fin cold plate have been also analyzed. Recommendation was made with regard to further tests providing more useful information of the cold plate performance.

  19. Simultaneous determination of a novel KDR kinase inhibitor and its N-oxide metabolite in human plasma using 96-well solid-phase extraction and liquid chromatography/tandem mass spectrometry.

    PubMed

    Xu, Yang; Du, Lihong; Soli, Eric D; Braun, Matthew P; Dean, Dennis C; Musson, Donald G

    2005-03-25

    To support pharmacokinetic studies, a selective and sensitive liquid chromatography/tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the simultaneous determination of a novel KDR kinase inhibitor (1) and its active metabolite (2) in human plasma. The method is fully automated using a Packard MultiPROBE II system and a TomTec Quadra 96 liquid handling workstation to perform sample preparation and solid-phase extraction (SPE). Following the extraction on a mixed-mode SPE using Oasis MCX 96-well plate, the analytes were separated on a Aquasil C18 column (50 mm x 2.1 mm, i.d., 3 microm) with a mobile phase consisting of acetonitrile/ammonium acetate buffer (5 mM, pH 5.0) (60/40, v/v). The run time for each injection was 4.5 min with the retention times of approximately 2.0 and 2.7 min for 1 and 2 respectively, at a flow rate of 0.25 mL/min. A tandem mass spectrometric detection was conducted using multiple reaction monitoring (MRM) under the positive ion mode with a turbo ion-spray interface. The linear ranges of the calibration curves were 0.05-400 ng/mL for 1 and 0.1-400 ng/mL for 2 on a PE Sciex API 4000 LC-MS/MS system. The lower limits of quantitation (LLOQ) of the assay were 0.05 and 0.1 ng/mL for 1 and 2 respectively, when 0.4 mL of plasma was processed. Intra-day assay precision (using five standard curves prepared by spiking compounds to five lots of plasma) was less than 4.9% for 1 and less than 9.6% for 2 on each concentration. Assay accuracy was found to be 95.1-104.6% of nominal for 1 standards and 93.5-105.6% for 2 standards. QC samples were stable when kept at room temperature for 4 h, at -70 degrees C for 10 days, and after three freeze-thaw cycles. The extraction recoveries were 80%, 83% and 84% for 1 and 2 and I.S. respectively, and no significant matrix effects were observed. The method was successfully applied to plasma samples from clinical studies after oral administration of compound 1. PMID:15686997

  20. Fiber-coupled laser-driven flyer plates system

    SciTech Connect

    Zhao Xinghai; Zhao Xiang; Gao Yang; Shan Guangcun

    2011-04-15

    A system for the launch of hypervelocity flyer plates has been developed and characterized. Laser-driven flyers were launched from the substrate backed aluminum-alumina-aluminum sandwiched films. A laser-induced plasma is used to drive flyers with typical thickness of 5.5 {mu}m and diameters of less than 1 mm, to achieve velocities of a few km/s. These flyer plates have many applications, from micrometeorite simulation to laser ignition. The flyer plates considered here have up to three layers: an ablation layer, to form plasma; an insulating layer; and a final, thicker layer that forms the final flyer plates. This technique was developed aiming at improving the energy efficiency of the system. The kinetic energy of flyers launched with the additional layer was found to be enhanced by a factor of near 2 (up to 30%). The optical fiber delivery system governs the output spatial profile of the laser spot and power capacity. Moreover, a technique for coupling high-power laser pulses into an optical fiber has been developed. This fiber optic system has been successfully used to launch flyer plates, and the surface finishing quality of the fiber was found to be an important factor. Importantly, measurements of the flyer performance including the mean velocities and planarity were made by an optical time-of-arrival technique using an optical fiber array probe, demonstrating the good planarity of the flyer and the achievable average velocity of 1.7 km/s with approaching 1 mm diameter. Finally, the relationship between flyer velocities and incident laser pulses energy was also investigated.

  1. Plate-Based Fuel Processing System Final Report

    SciTech Connect

    Carlos Faz; Helen Liu; Jacques Nicole; David Yee

    2005-12-22

    On-board reforming of liquid fuels into hydrogen is an enabling technology that could accelerate consumer usage of fuel cell powered vehicles. The technology would leverage the convenience of the existing gasoline fueling infrastructure while taking advantage of the fuel cell efficiency and low emissions. Commercial acceptance of on-board reforming faces several obstacles that include: (1) startup time, (2) transient response, and (3) system complexity (size, weight and cost). These obstacles are being addressed in a variety of projects through development, integration and optimization of existing fuel processing system designs. In this project, CESI investigated steam reforming (SR), water-gas-shift (WGS) and preferential oxidation (PrOx) catalysts while developing plate reactor designs and hardware where the catalytic function is integrated into a primary surface heat exchanger. The plate reactor approach has several advantages. The separation of the reforming and combustion streams permits the reforming reaction to be conducted at a higher pressure than the combustion reaction, thereby avoiding costly gas compression for combustion. The separation of the two streams also prevents the dilution of the reformate stream by the combustion air. The advantages of the plate reactor are not limited to steam reforming applications. In a WGS or PrOx reaction, the non-catalytic side of the plate would act as a heat exchanger to remove the heat generated by the exothermic WGS or PrOx reactions. This would maintain the catalyst under nearly isothermal conditions whereby the catalyst would operate at its optimal temperature. Furthermore, the plate design approach results in a low pressure drop, rapid transient capable and attrition-resistant reactor. These qualities are valued in any application, be it on-board or stationary fuel processing, since they reduce parasitic losses, increase over-all system efficiency and help perpetuate catalyst durability. In this program, CESI

  2. System Advisor Model: Flat Plate Photovoltaic Performance Modeling Validation Report

    SciTech Connect

    Freeman, J.; Whitmore, J.; Kaffine, L.; Blair, N.; Dobos, A. P.

    2013-12-01

    The System Advisor Model (SAM) is a free software tool that performs detailed analysis of both system performance and system financing for a variety of renewable energy technologies. This report provides detailed validation of the SAM flat plate photovoltaic performance model by comparing SAM-modeled PV system generation data to actual measured production data for nine PV systems ranging from 75 kW to greater than 25 MW in size. The results show strong agreement between SAM predictions and field data, with annualized prediction error below 3% for all fixed tilt cases and below 8% for all one axis tracked cases. The analysis concludes that snow cover and system outages are the primary sources of disagreement, and other deviations resulting from seasonal biases in the irradiation models and one axis tracking issues are discussed in detail.

  3. Sensor network based vehicle classification and license plate identification system

    SciTech Connect

    Frigo, Janette Rose; Brennan, Sean M; Rosten, Edward J; Raby, Eric Y; Kulathumani, Vinod K

    2009-01-01

    Typically, for energy efficiency and scalability purposes, sensor networks have been used in the context of environmental and traffic monitoring applications in which operations at the sensor level are not computationally intensive. But increasingly, sensor network applications require data and compute intensive sensors such video cameras and microphones. In this paper, we describe the design and implementation of two such systems: a vehicle classifier based on acoustic signals and a license plate identification system using a camera. The systems are implemented in an energy-efficient manner to the extent possible using commercially available hardware, the Mica motes and the Stargate platform. Our experience in designing these systems leads us to consider an alternate more flexible, modular, low-power mote architecture that uses a combination of FPGAs, specialized embedded processing units and sensor data acquisition systems.

  4. Convection pattern and stress system under the African plate

    NASA Technical Reports Server (NTRS)

    Liu, H.-S.

    1977-01-01

    Studies on tectonic forces from satellite-derived gravity data have revealed a subcrustal stress system which provides a unifying mechanism for uplift, depression, rifting, plate motion and ore formation in Africa. The subcrustal stresses are due to mantle convection. Seismicity, volcanicity and kimberlite magmatism in Africa and the development of the African tectonic and magnetic features are explained in terms of this single stress system. The tensional stress fields in the crust exerted by the upwelling mantle flows are shown to be regions of structural kinship characterized by major concentration of mineral deposits. It is probable that the space techniques are capable of detecting and determining the tectonic forces in the crust of Africa.

  5. Resonances of piezoelectric plate with embedded 2D electron system

    NASA Astrophysics Data System (ADS)

    Suslov, A. V.

    2009-02-01

    A thin GaAs/AlGaAs plate was studied by the resonant ultrasound spectroscopy (RUS) in the temperature range 0.3-10 K and in magnetic fields of up to 18 T. The resonance frequencies and linewidths were measured. Quantum oscillations of both these values were observed and were associated with the quantum Hall effect occurred in the 2D electron system. For an analysis the sample was treated as a dielectric piezoelectric plate covered on one side by a film with a field dependent conductivity. Screening of the strain-driven electric field was changed due to the variation of the electron relaxation time in the vicinity of the metal-dielectric transitions caused by the magnetic field in the 2D system. The dielectric film does not affect properties of GaAs and thus the resonance frequencies are defined only by the elastic, piezoelectric and dielectric constants of GaAs. A metallic 2D sheet effectively screens the parallel electric field, so the ultrasound wave velocities and resonance frequencies decrease when the sheet conductivity increases. Oscillations of the resonance linewidth reflect the influence of the 2D system on the ultrasound attenuation, which is proportional to the linewidth. A metallic film as well as a dielectric one does not affect this attenuation but at some finite nonzero value of the conductivity the linewidth approaches a maximum. In high magnetic field each oscillation of the conductivity produces one oscillation of a resonance frequency and two linewidth peaks. The observed phenomena can be described by the relaxation type equations and the resonant ultrasound spectroscopy opens another opportunity for contactless studies on 2D electron systems.

  6. 76 FR 60531 - National Institute of Justice Interview Room Recording Systems and License Plate Readers Workshop

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-29

    ... webpage to register for the License Plate Reader workshop: http://www.surveymonkey.com/s/ALPR_workshop_reg... Interview Room Recording Systems will take place from 8 to 9:30 a.m. The License Plate Reader session will... Plate Readers Workshop AGENCY: National Institute of Justice. ACTION: Notice of the Interview...

  7. The Pd2Si - /Pd/ - Ni - solder plated metallization system for silicon solar cells

    NASA Technical Reports Server (NTRS)

    Coleman, M. G.; Pryor, R. A.; Sparks, T. G.

    1978-01-01

    The rationale and application of a plated metal system, Pd2Si Pd - Ni - solder, is presented. This metallization system is particularly useful on shallow p-n junction solar cells. The advantages of such plated solar cell contacts are discussed. A process sequence for applying the metallization system is outlined. A specific example is presented, including chemical plating solution formulations and detailed process step descriptions. Electrical test data for solar cells metallized with the palladium-nickel-solder system are provided.

  8. Aberration analysis of a wedge-plate display system.

    PubMed

    Cheng, Yi-Kai; Chung, Sen-Nien; Chern, Jyh-Long

    2007-08-01

    The aberration characteristics of a wedge-plate display optical system are analyzed. The study shows that a kink-like feature is inherent in the ray-intercept curve due to either the onset of the dark zone in imaging or the coincidence of the ray direction with the vertex. Third-order aberration coefficients are deduced, and the total amount of aberration is investigated to illustrate the basic limitations of image quality in this type of display. The issue of design optimization is also investigated based on the aberration characteristics. A numerical example of a 50 in. display with a 1:10 thickness and a diagonal screen length ratio is also provided. PMID:17621338

  9. A combined lift and propulsion system of a steel plate by transverse flux linear induction motors

    SciTech Connect

    Hayashiya, H.; Ohsaki, H.; Masada, E.

    1999-09-01

    To realize a non-contacting conveyance of a steel plate, a combined lift and propulsion system of a steel plate by transverse flux linear induction motors (LIMs) is proposed. By introducing the DC biased AC feeding to the LIM< a steel plate is supported stably and efficiently. In this paper, after showing the advantages of the system, the magnetic levitation experiments are carried out to investigate the feasibility of the system.

  10. RBFNN-based hole identification system in conducting plates.

    PubMed

    Simone, G; Morabito, F C

    2001-01-01

    A neural-based signal processing system that exploits radial basis function neural network (RBFNN) is proposed to solve the problem of detecting and locating circular holes in conducting plates by means of nondestructive eddy currents testing. The capabilities of basic multilayer perceptron and radial basis function (RBF) schemes are first investigated. Since the achieved performance revealed insufficient, a two-step procedure is then analyzed: in the first step, an RBFNN is used to estimate the distances between the hole's center and the eddy current magnetic sensors; a least square algorithm is then exploited in order to locate the hole starting from the previously estimated distances. The performance of the proposed system are tested on a database of simulated experiments based on the a priori knowledge of the corresponding boundary value direct problem solution, by taking advantage of the closed-form analytical expression of the solution in order to generate a wide range of possible sensor-hole configurations. Both noiseless and noisy measurements are taken into account for assessing the system robustness. The main result achieved is discussed. PMID:18249972

  11. Geodynamic reconstructions of the South America-Antarctica plate system

    NASA Astrophysics Data System (ADS)

    Vérard, Christian; Flores, Kennet; Stampfli, Gérard

    2012-01-01

    The South America-Antarctica plate system shows many oceanic accretionary systems and subduction zones that initiated and then stopped. To better apprehend the evolution of the system, geodynamic reconstructions (global) have been created from Jurassic (165 Ma) to present, following the techniques used at the University of Lausanne. However, additional synthetic magnetic anomalies were used to refine the geodynamics between 33 Ma and present. The reconstructions show the break up of Gondwana with oceanisation between South America (SAM) and Antarctica (ANT), together with the break off of 'Andean' geodynamical units (GDUs). We propose that oceanisation occurs also east and south of the Scotian GDUs. Andean GDUs collide with other GDUs crossing the Pacific. The west coast of SAM and ANT undergo a subsequent collision with all those GDUs between 103 Ma and 84 Ma, and the Antarctic Peninsula also collides with Tierra del Fuego. The SAM-ANT plate boundary experienced a series of extension and shortening with large strike-slip component, culminating with intra-oceanic subduction leading to the presence of the 'V-' and 'T-' anomalies in the Weddell Sea. From 84 Ma, a transpressive collision takes place in the Scotia region, with active margin to the east. As subduction propagates northwards into an old and dense oceanic crust, slab roll-back initiates, giving rise to the western Scotia Sea and the Powell Basin opening. The Drake Passage opens. As the Scotian GDUs migrate eastwards, there is enough space for them to spread and allow a north-south divergence with a spreading axis acting simultaneously with the western Scotia ridge. Discovery Bank stops the migration of South Orkney and 'collides with' the SAM-ANT spreading axis, while the northern Scotian GDUs are blocked against the Falkland Plateau and the North-East Georgia Rise. The western and central Scotia and the Powell Basin spreading axes must cease, and the ridge jumps to create the South Sandwich Islands Sea

  12. A novel fixation system for acetabular quadrilateral plate fracture: a comparative biomechanical study.

    PubMed

    Zha, Guo-Chun; Sun, Jun-Ying; Dong, Sheng-Jie; Zhang, Wen; Luo, Zong-Ping

    2015-01-01

    This study aims to assess the biomechanical properties of a novel fixation system (named AFRIF) and to compare it with other five different fixation techniques for quadrilateral plate fractures. This in vitro biomechanical experiment has shown that the multidirectional titanium fixation (MTF) and pelvic brim long screws fixation (PBSF) provided the strongest fixation for quadrilateral plate fracture; the better biomechanical performance of the AFRIF compared with the T-shaped plate fixation (TPF), L-shaped plate fixation (LPF), and H-shaped plate fixation (HPF); AFRIF gives reasonable stability of treatment for quadrilateral plate fracture and may offer a better solution for comminuted quadrilateral plate fractures or free floating medial wall fracture and be reliable in preventing protrusion of femoral head. PMID:25802849

  13. Relative motions of the Australian, Pacific and Antarctic plates estimated by the Global Positioning System

    NASA Technical Reports Server (NTRS)

    Larson, Kristine M.; Freymueller, Jeff

    1995-01-01

    Global Positioning System (GPS) measurements spanning approximately 3 years have been used to determine velocities for 7 sites on the Australian, Pacific and Antarctic plates. The site velocities agree with both plate model predictions and other space geodetic techniques. We find no evidence for internal deformation of the interior of the Australian plate. Wellington, New Zealand, located in the Australian-Pacific plate boundary zone, moves 20 +/- 5 mm/yr west-southwest relative to the Australian plate. Its velocity lies midway between the predicted velocities of the two plates. Relative Euler vectors for the Australia-Antarctica and Pacific-Antarctica plates agree within one standard deviation with the NUVEL-1A predictions.

  14. Development and Clinical Evaluation of MatrixMANDIBLE Subcondylar Plates System (Synthes).

    PubMed

    Cortelazzi, Roberto; Altacera, Mario; Turco, Monica; Antonicelli, Viviana; De Benedittis, Michele

    2015-06-01

    In this article, authors report the different steps of development and clinical validation of MatrixMANDIBLE Subcondylar Plates (Synthes, Soletta, Switzerland), a specialized osteosynthesis system developed by Synthes during the past 4 years. Between 2009 and 2013, a total of 62 patients were treated for subcondylar and condylar neck fractures via a preauricular or retromandibular/transparotid approach. The MatrixMANDIBLE Subcondylar Plates System consists of a Trapezoidal Plate, a three-dimensional (3D) 4-hole 1.0-mm plate for smaller fracture areas, the Lambda Plate, a 7-hole 1.0-mm linear plate which mimics the two miniplates technique, and the Strut Plate, a 3D 1.0-mm plate with great versatility of employment. All devices satisfy the principles of a functionally stable osteosynthesis as stated by Champy et al. None of the plates broke and no macroscopic condylar displacement was noted on radiological follow-up. Clinical and functional parameters assessed at 6 months postoperative (mandibular range of motion, pain, dental occlusion) were almost restored. MatrixMANDIBLE Subcondylar Plates System (Synthes) has proved to provide sufficient mechanical stiffness and anatomically accurate fracture reduction to avoid major postoperative drawbacks of subcondylar and condylar neck fractures. PMID:26000078

  15. Development and Clinical Evaluation of MatrixMANDIBLE Subcondylar Plates System (Synthes)

    PubMed Central

    Cortelazzi, Roberto; Altacera, Mario; Turco, Monica; Antonicelli, Viviana; De Benedittis, Michele

    2014-01-01

    In this article, authors report the different steps of development and clinical validation of MatrixMANDIBLE Subcondylar Plates (Synthes, Soletta, Switzerland), a specialized osteosynthesis system developed by Synthes during the past 4 years. Between 2009 and 2013, a total of 62 patients were treated for subcondylar and condylar neck fractures via a preauricular or retromandibular/transparotid approach. The MatrixMANDIBLE Subcondylar Plates System consists of a Trapezoidal Plate, a three-dimensional (3D) 4-hole 1.0-mm plate for smaller fracture areas, the Lambda Plate, a 7-hole 1.0-mm linear plate which mimics the two miniplates technique, and the Strut Plate, a 3D 1.0-mm plate with great versatility of employment. All devices satisfy the principles of a functionally stable osteosynthesis as stated by Champy et al. None of the plates broke and no macroscopic condylar displacement was noted on radiological follow-up. Clinical and functional parameters assessed at 6 months postoperative (mandibular range of motion, pain, dental occlusion) were almost restored. MatrixMANDIBLE Subcondylar Plates System (Synthes) has proved to provide sufficient mechanical stiffness and anatomically accurate fracture reduction to avoid major postoperative drawbacks of subcondylar and condylar neck fractures. PMID:26000078

  16. Automated Filtration-Based High-Throughput Plasmid Preparation System

    PubMed Central

    Itoh, Masayoshi; Kitsunai, Tokuji; Akiyama, Junichi; Shibata, Kazuhiro; Izawa, Masaki; Kawai, Jun; Tomaru, Yasuhiro; Carninci, Piero; Shibata, Yuko; Ozawa, Yasuhiro; Muramatsu, Masami; Okazaki, Yasushi; Hayashizaki, Yoshihide

    1999-01-01

    Current methods of plasmid preparation do not allow for large capacity automated processing. We have developed an automated high-throughput system that prepares plasmid DNA for large-scale sequencing. This system is based on our previously reported filtration method. In this method, cell harvesting, alkaline lysis, and plasmid purification occur in a single 96-well microtiter plate from which sequence-ready DNA samples are collected. The plates are designed to allow all reagents to be injected from above the wells and the spent reagents to be aspirated from below. This design has enabled us to build a linear process plasmid preparation system consisting of an automated filter plate stacker and a 21-stage automated plasmid preparator. The 96-well plates used are outfitted with glass-filters that trap Escherichia coli before the plates are stacked in the automated stacker. The plates move from the stacker to each of the 21 stages of the preparator. At specific stages, various reagents or chemicals are injected into the wells from above. Finally, the plates are collected in the second stacker. The optimal throughput of the preparator is 40,000 samples in 17.5 hr. Here, we describe a pilot experiment preparing 15,360 templates in 160 specially designed 96-well glass-filter plates. The prepared plasmids were subjected to restriction digestion, DNA sequencing, and transcriptional sequencing. PMID:10330126

  17. Plate Motion and Crustal Deformation Estimated with Geodetic Data from the Global Positioning System

    NASA Technical Reports Server (NTRS)

    Argus, Donald F.; Heflin, Michael B.

    1995-01-01

    We use geodetic data taken over four years with the Global Positioning System (GPS) to estimate: (1) motion between six major plates and (2) motion relative to these plates of ten sites in plate boundary zones. The degree of consistency between geodetic velocities and rigid plates requires the (one-dimensional) standard errors in horizontal velocities to be approx. 2 mm/yr. Each of the 15 angular velocities describing motion between plate pairs that we estimate with GPS differs insignificantly from the corresponding angular velocity in global plate motion model NUVEL-1A, which averages motion over the past 3 m.y. The motion of the Pacific plate relative to both the Eurasian and North American plates is observed to be faster than predicted by NUVEL-1A, supporting the inference from Very Long B ase- line Interferometry (VLBI) that motion of the Pacific plate has speed up over the past few m.y. The Eurasia-North America pole of rotation is estimated to be north of NUVEL-1A, consistent with the independent hypothesis that the pole has recently migrated northward across northeast Asia to near the Lena River delta. Victoria, which lies above the main thrust at the Cascadia subduction zone, moves relative to the interior of the overriding plate at 30% of the velocity of the subducting plate, reinforcing the conclusion that the thrust there is locked beneath the continental shelf and slope.

  18. Soluble penicillin-binding protein 2a: beta-lactam binding and inhibition by non-beta-lactams using a 96-well format.

    PubMed

    Toney, J H; Hammond, G G; Leiting, B; Pryor, K D; Wu, J K; Cuca, G C; Pompliano, D L

    1998-01-01

    High level methicillin resistance in Staphylococcus aureus is dependent upon the acquisition of the mecA gene encoding penicillin-binding protein 2a (PBP2a). PBP2a is a member of a family of peptidoglycan biosynthetic enzymes involved in assembly of the cell wall in bacteria and is poorly inactivated by beta-lactam antibiotics. We describe a 96-well-filter binding assay using recombinant, soluble PBP2a which allows for kinetic measurement of penicillin binding. The deacylation rate constant for the PBP2a-penicillin G covalent complex was found to be 5.7 +/- 1.0 x 10(-5) s-1 at 30 degrees C (half-life of approximately 200 min). For the PBP2a acylation reaction, the value of K(m) (penicillin G) = 0.5 +/- 0.1 mM and kcat = 1 x 10(-3) s-1, which yields a second-order rate constant (kcat/K(m)) for inactivation of 2.0 M-1 s-1. Using this assay, several non-beta-lactam inhibitors including Cibacron blue have been found which exhibit IC50 values between 10 and 30 microM. The binding affinities of several carbapenems and beta-lactams correlated well between the filter binding assay described in this report and an electrophoretic assay for PBP2a using membranes prepared form methicillin-resistant S. aureus. PMID:9448849

  19. Paper microzone plates.

    PubMed

    Carrilho, Emanuel; Phillips, Scott T; Vella, Sarah J; Martinez, Andres W; Whitesides, George M

    2009-08-01

    This paper describes 96- and 384-microzone plates fabricated in paper as alternatives to conventional multiwell plates fabricated in molded polymers. Paper-based plates are functionally related to plastic well plates, but they offer new capabilities. For example, paper-microzone plates are thin (approximately 180 microm), require small volumes of sample (5 microL per zone), and can be manufactured from inexpensive materials ($0.05 per plate). The paper-based plates are fabricated by patterning sheets of paper, using photolithography, into hydrophilic zones surrounded by hydrophobic polymeric barriers. This photolithography used an inexpensive formulation photoresist that allows rapid (approximately 15 min) prototyping of paper-based plates. These plates are compatible with conventional microplate readers for quantitative absorbance and fluorescence measurements. The limit of detection per zone loaded for fluorescence was 125 fmol for fluorescein isothiocyanate-labeled bovine serum albumin, and this level corresponds to 0.02 the quantity of analyte per well used to achieve comparable signal-to-noise in a 96-well plastic plate (using a solution of 25 nM labeled protein). The limits of detection for absorbance on paper was approximately 50 pmol per zone for both Coomassie Brilliant Blue and Amaranth dyes; these values were 0.4 that required for the plastic plate. Demonstration of quantitative colorimetric correlations using a scanner or camera to image the zones and to measure the intensity of color, makes it possible to conduct assays without a microplate reader. PMID:19572563

  20. Evaluation of PSPL plate erasing time of a digital dental radiology system

    NASA Astrophysics Data System (ADS)

    Albuquerque, Jorge A. G.; Costa, Eduardo T.; Neto, Francisco H.; Paganinni, Gisela A.; Boscolo, Frab N.; de Oliveira, Ana E. F.

    2001-06-01

    Denoptix (CEDH Gendex, USA) dental imaging system uses photo-stimulable phosphor luminescence (PSPL) plates to store energy during X-ray exposure, being later processed by a laser reader and digitizer. Afterwards the plate is erased and re-used. The cleaning process described by the manufacturer consists of exposing the PSPL plates to negatoscope light for 5 minutes. Proper light intensity and exact erasing time must be considered in order to guarantee good quality procedures in its re-utilization. X-ray exposed plates were submitted to four negatoscopes with different measured light intensities for several periods of light exposure, until the Denoptix system was unable to process the latent image in the plates, and we considered then that the plates were cleaned. We have found the relationships between erasing time, exposed dose and negatoscope light intensity. We have also measured the relative plate image fading with negatoscope light exposure time. We have concluded that a Poisson process governs plate erasing. Considering clinical situations, we have shown that it was possible to largely reduce erasing time and increase plate re-utilization. The exponential decay of image data also suggested a still smaller erasing time, representative of a partial cleaning status assuming that residual noise presence in the erased plate is clinically acceptable.

  1. Determination of the HIV integrase inhibitor, MK-0518 (raltegravir), in human plasma using 96-well liquid-liquid extraction and HPLC-MS/MS.

    PubMed

    Merschman, S A; Vallano, P T; Wenning, L A; Matuszewski, B K; Woolf, E J

    2007-09-15

    An HPLC-MS/MS method was developed for the determination of MK-0518 (raltegravir), an HIV integrase inhibitor, in human plasma over the concentration range of 2-1000 ng/mL. Stable isotope labeled (13)C(6)-MK-0518 was used as an internal standard. The sample preparation procedure utilized liquid-liquid extraction with hexane:methylene chloride in the 96-well format with a 200 microL plasma sample size. The compounds were chromatographed on an Ace C(18) (50 x 3.0 mm, 3 microm, titanium frits) column with 42.5/57.5 (v/v %) 0.1mM EDTA in 0.1% formic acid/methanol mobile phase at a flow rate of 0.5 mL/min. Multiple reaction monitoring of the precursor-to-product ion pairs for MK-0518 (m/z 445-->109) and (13)C(6)-MK-0518 (m/z 451-->367) on an Applied Biosystem API 4000 HPLC-MS/MS was used for quantitation. Intraday precision of standard curve concentrations in five different lots of control plasma was within 3.2%, while accuracy ranged from 94.8 to 106.8%. The mean extraction recovery of spiked plasma samples was 87%. Quality control (QC) samples were stored at -20 degrees C. Initial within day analysis showed QC accuracy within 7.5% of nominal with precision of 3.1% or less. The plasma QC samples were demonstrated to be stable for up to 23 months at -20 degrees C. The method described has been used to support over 18 clinical studies during Phase I through III of clinical development. PMID:17644453

  2. A Compact Immunoassay Platform Based on a Multicapillary Glass Plate

    PubMed Central

    Xue, Shuhua; Zeng, Hulie; Yang, Jianmin; Nakajima, Hizuru; Uchiyama, Katsumi

    2014-01-01

    A highly sensitive, rapid immunoassay performed in the multi-channels of a micro-well array consisting of a multicapillary glass plate (MCP) and a polydimethylsiloxane (PDMS) slide is described. The micro-dimensions and large surface area of the MCP permitted the diffusion distance to be decreased and the reaction efficiency to be increased. To confirm the concept of the method, human immunoglobulin A (h-IgA) was measured using both the proposed immunoassay system and the traditional 96-well plate method. The proposed method resulted in a 1/5-fold decrease of immunoassay time, and a 1/56-fold cut in reagent consumption with a 0.05 ng/mL of limit of detection (LOD) for IgA. The method was also applied to saliva samples obtained from healthy volunteers. The results correlated well to those obtained by the 96-well plate method. The method has the potential for use in disease diagnostic or on-site immunoassays. PMID:24859022

  3. Multi-well sample plate cover penetration system

    DOEpatents

    Beer, Neil Reginald

    2011-12-27

    An apparatus for penetrating a cover over a multi-well sample plate containing at least one individual sample well includes a cutting head, a cutter extending from the cutting head, and a robot. The cutting head is connected to the robot wherein the robot moves the cutting head and cutter so that the cutter penetrates the cover over the multi-well sample plate providing access to the individual sample well. When the cutting head is moved downward the foil is pierced by the cutter that splits, opens, and folds the foil inward toward the well. The well is then open for sample aspiration but has been protected from cross contamination.

  4. The Core Services of the European Plate Observing System (EPOS)

    NASA Astrophysics Data System (ADS)

    Hoffmann, T. L.; Euteneuer, F. H.; Lauterjung, J.

    2013-12-01

    The ESFRI project European Plate Observing System (EPOS) was launched in November 2010 and has now completed its year 3 of the four-year preparatory phase. EPOS will create a single sustainable, permanent observation infrastructure, integrating existing geophysical monitoring networks, local observatories and experimental laboratories in Europe and adjacent regions. EPOS' technical Work Package 6 has developed a three layer architectural model for the construction of the EPOS Core Services (CS) during the subsequent implementation phase. The Poster will present and detail on these three layers, consisting of the EPOS Integrated Core Services (ICS), the Thematic Core Services (TCS) and the existing National Research Infrastructures & Data Centers. The basic layer of the architecture is established by the National Research Infrastructures (RIs) & Data Centers, which generate data and information and are responsible for the operation of the instrumentation. National RIs will provide their data to the Thematic Cores Services. The Thematic Core Services constitute the community layer of EPOS architecture and they will: 1) consist of existing (e.g. ORFEUS, EMSC), developing (e.g. EUREF/GNSS) or still to be developed Service Providers for specific thematic communities, as represented within EPOS through the technical EPOS Working Groups (e.g., seismology, volcanology, geodesy, geology, analytic labs for rock physics, geomagnetism, geo-resources ... and many others), 2) provide data services to specific communities, 3) link the National Research Infrastructures to the EPOS Integrated Services, 4) include Service Providers (e.g. OneGeology+, Intermagnet) that may be merely linked or partially integrated and 5) consist of Integrated Laboratories and RIs spanning multiple EPOS disciplines and taking advantage of other existing Thematic Services. The EPOS Integrated Services constitute the ICT layer of the EPOS portal and they will: 1) provide access to multidisciplinary data

  5. Lengthening over nails using the double plate system ONAS-DPS.

    PubMed

    Antolič, Vane

    2016-01-01

    Stable insertion of large Schanz screws behind an intramedullary (IM) nail when lengthening over nails (LON) may be difficult due to the limited bone stock. Additionally, the highly probable contact between the screws and IM nail (which is difficult to avoid) increases the likelihood of infection spreading from the skin via Schanz screws directly to the IM nail. A new device for LON has been developed. Instead of inserting Schanz screws from the external fixator beside the IM nail (as in standard LON), a system of two overlaying plates was constructed. Schanz screws can be fixed to the plates without entering the bone. The plates are fixed to the bone using four angle stability screws. The holes in the plates offer stabile fixation for a chosen angle under which the screw is positioned through the cortical bone. Using the new system there is no need to place Schanz screws behind the IM nail. Instead, Schanz screws pass to the plate and not through the bone. The new system for elongation over IM nail is called "Over Nail Angle Stability-Double Plate System" (ONAS-DPS) [Antolič V (2013) Modular side device with an intramedullary nail for guiding a bone during its lengthening. World Intellectual Property Organization. International Publication number: WO 2013/176632 A1]. PMID:27163094

  6. Characterization of a resonant plate shock system using finite element analysis

    SciTech Connect

    Gute, G.D.; Moore, D.G.

    1995-10-01

    The dynamic performance of a 250 Hz resonant plate shock system which simulates pyrotechnic shock environments on micro-electrical components is evaluated. A series of experiments recording strain rate histories and acceleration time histories at several plate locations were conducted. This empirical data is used to compare the analytical results obtained from a finite element based numerical simulation. The comparison revealed a good correlation between experimental and analytical results.

  7. Lengthening over nails using the double plate system ONAS-DPS

    PubMed Central

    Antolič, Vane

    2016-01-01

    Stable insertion of large Schanz screws behind an intramedullary (IM) nail when lengthening over nails (LON) may be difficult due to the limited bone stock. Additionally, the highly probable contact between the screws and IM nail (which is difficult to avoid) increases the likelihood of infection spreading from the skin via Schanz screws directly to the IM nail. A new device for LON has been developed. Instead of inserting Schanz screws from the external fixator beside the IM nail (as in standard LON), a system of two overlaying plates was constructed. Schanz screws can be fixed to the plates without entering the bone. The plates are fixed to the bone using four angle stability screws. The holes in the plates offer stabile fixation for a chosen angle under which the screw is positioned through the cortical bone. Using the new system there is no need to place Schanz screws behind the IM nail. Instead, Schanz screws pass to the plate and not through the bone. The new system for elongation over IM nail is called “Over Nail Angle Stability-Double Plate System” (ONAS-DPS) [Antolič V (2013) Modular side device with an intramedullary nail for guiding a bone during its lengthening. World Intellectual Property Organization. International Publication number: WO 2013/176632 A1]. PMID:27163094

  8. Degradation behaviour of LAE442-based plate-screw-systems in an in vitro bone model.

    PubMed

    Wolters, Leonie; Besdo, Silke; Angrisani, Nina; Wriggers, Peter; Hering, Britta; Seitz, Jan-Marten; Reifenrath, Janin

    2015-04-01

    The use of absorbable implant materials for fixation after bone fracture helps to avoid a second surgery for implant removal and the risks and costs involved. Magnesium (Mg) is well known as a potential metallic material for degradable implants. The aim of the present in vitro study was to evaluate if degradable LAE442-based magnesium plate-screw-systems are suitable candidates for osteosynthesis implants in load-bearing bones. The corrosion behaviour was tested concerning the influence of different surface treatments, coatings and screw torques. Steel plates and screws of the same size served as control. Plates without special treatment screwed on up to a specified torque of 15cNm or 7cNm, NaOH treated plates (15cNm), magnesium fluoride coated plates (15cNm) and steel plates as control (15cNm) were examined in pH-buffered, temperature-controlled SBF solution for two weeks. The experimental results indicate that the LAE442 plates and screws coated with magnesium fluoride revealed a lower hydrogen evolution in SBF solution as well as a lower weight loss and volume decrease in μ-computed tomography (μCT). The nanoindentation and SEM/EDX measurements at several plate areas showed no significant differences. Summarized, the different screw torques did not affect the corrosion behaviour differently. Also the NaOH treatment seemed to have no essential influence on the degradation kinetics. The plates coated with magnesium fluoride showed a decreased corrosion rate. Hence, it is recommended to consider this coating for the next in vivo study. PMID:25686954

  9. Evaluation of the Minnesota Easy Culture System II Bi-Plate and Tri-Plate for identification of common mastitis pathogens in milk.

    PubMed

    Royster, E; Godden, S; Goulart, D; Dahlke, A; Rapnicki, P; Timmerman, J

    2014-01-01

    The objective of this study was to validate use of the Minnesota Easy Culture System II Bi-Plate and Tri-Plate (University of Minnesota Laboratory for Udder Health, St. Paul) to identify common mastitis pathogens in milk. A total of 283 quarter and composite milk samples submitted to the University of Minnesota Laboratory for Udder Health during the spring of 2010 were cultured simultaneously using 3 methods: standard laboratory culture (reference method) and the Minnesota Easy Culture System II Bi-Plate and Tri-Plate methods. Bi-Plate and Tri-Plate cultures were incubated for 18 to 24h and interpreted by 2 independent, untrained readers within 5h of each other. An experienced technician completed the standard laboratory culture. For each sample, all 3 study personnel recorded the culture result (yes/no) for each of the following diagnostic categories: no bacterial growth (NG), mixed (2 organisms), contaminated (3 or more organisms), gram-positive (GP), gram-negative (GN), Staphylococcus spp., Streptococcus spp., Streptococcus agalactiae, Streptococcus dysgalactiae, Streptococcus uberis, Enterococcus spp., Staphylococcus aureus, coagulase-negative staphylococci, Escherichia coli, Klebsiella spp., and other. For each category, the prevalence, sensitivity, specificity, accuracy, and predictive values of a positive and negative test were calculated, and the agreement between readers and between each reader and the laboratory was assessed. Specificity, overall accuracy, and negative predictive values were generally high (>80%) for the Bi-Plate and Tri-Plate for each category. Sensitivity and positive predictive values were intermediate (>60%) or high (>80%) for the broad categories of NG, GP, GN, Staphylococcus spp. and Streptococcus spp., and for Staph. aureus, but were generally lower (<60%) for other more specific categories. Similarly, interreader agreement (kappa value) was moderate to substantial (40-80%) for the broad categories of NG, GP, GN, Staphylococcus spp

  10. GMFilter and SXTestPlate: software tools for improving the SNPlex™ genotyping system

    PubMed Central

    Teuber, Markus; Wenz, Michael H; Schreiber, Stefan; Franke, Andre

    2009-01-01

    Background Genotyping of single-nucleotide polymorphisms (SNPs) is a fundamental technology in modern genetics. The SNPlex™ mid-throughput genotyping system (Applied Biosystems, Foster City, CA, USA) enables the multiplexed genotyping of up to 48 SNPs simultaneously in a single DNA sample. The high level of automation and the large amount of data produced in a high-throughput laboratory require advanced software tools for quality control and workflow management. Results We have developed two programs, which address two main aspects of quality control in a SNPlex™ genotyping environment: GMFilter improves the analysis of SNPlex™ plates by removing wells with a low overall signal intensity. It enables scientists to automatically process the raw data in a standardized way before analyzing a plate with the proprietary GeneMapper software from Applied Biosystems. SXTestPlate examines the genotype concordance of a SNPlex™ test plate, which was typed with a control SNP set. This program allows for regular quality control checks of a SNPlex™ genotyping platform. It is compatible to other genotyping methods as well. Conclusion GMFilter and SXTestPlate provide a valuable tool set for laboratories engaged in genotyping based on the SNPlex™ system. The programs enhance the analysis of SNPlex™ plates with the GeneMapper software and enable scientists to evaluate the performance of their genotyping platform. PMID:19267942

  11. Evaluation of a force plate system for measuring center of pressure in railroad ballast.

    PubMed

    Xu, Hang; Merryweather, Andrew; Bloswick, Donald

    2016-05-01

    Traditional biomechanical analyses have focused primarily on the human gait across hard, flat surfaces and provide little information about human locomotion as a function of work environment or terrain. The purpose of this study was evaluation of a force plate system for measure of center of pressure (COP) in railroad ballast by comparing its accuracy across three surface conditions (hard surface, mainline ballast and walking ballast) with two configurations (level and 7° cross-slope). Custom walkways and an isolation fixture were developed to rigidly attach a force plate beneath ballast surfaces to collect the COP. The difference in COP location (ΔCOPx, y, z) between the force plate system and a calibration system (motion capture derived) were compared using repeated-measures analysis of variance. Results indicate that the effects of surface condition and configuration were not significant for ΔCOPx, y, z and no differences were found among the three surface conditions during pairwise comparison, though ΔCOPx, y, z were different between the center and corners of the force plate in ballasts for both level and cross-slope configurations. The system presented in this study demonstrates the feasibility of measuring the COP by using an isolation-fixture force plate to expand the scope of biomechanical studies on ballast surfaces that are level or cross-slope. PMID:27131198

  12. Sensitivity Characteristics Of A Prototype Selenium Plate Detection System For Digital Radiographic Imaging

    NASA Astrophysics Data System (ADS)

    Papin, Patrick J.; Mankovich, Nicholas J.; Huang, H. K.

    1985-06-01

    We present an X ray measurement methodology with some preliminary X ray sensitivity characteristics for a prototype digital radiography system using amorphous selenium as the primary image receptor. As an imaging modality this experimental electrostatic system has the potential to replace film in existing general diagnostic radiography procedures. The imaging plate consists of a 360 micron layer of amorphous selenium deposited on an aluminumoxide substrate. An initial plate charge of 1400 volts (3.9 volts per micron) was exposed to X ray spectra produced with 50, 70, and 90 kVp with total filtration of 3 mm aluminum and 9 cm lucite. After this exposure the plate was scanned by a bank of electrometer probes at a distance of 100 microns. Sensitometric comparisons were then made to a conventional calcium-tungstate film-screen combination. The sensiometric response of the system is shown to be linear with an almost four fold increase in exposure latitude.

  13. Oscillations of a spring-magnet system damped by a conductive plate

    NASA Astrophysics Data System (ADS)

    Ladera, C. L.; Donoso, G.

    2013-09-01

    We study the motion of a spring-magnet system that oscillates with very low frequencies above a circular horizontal non-magnetizable conductive plate. The magnet oscillations couple with the plate via the Foucault currents induced therein. We develop a simple theoretical model for this magneto-mechanical oscillator, a model that leads to the equation of a damped harmonic oscillator, whose weak attenuation constant depends upon the system parameters, e.g. the electrical conductivity of the constituent material of the plate and its thickness. We present a set of validating experiments, the results of which are predicted with good accuracy by our analytical model. Additional experiments can be performed with this oscillating system or its variants. This oscillator is simple and low-cost, easy to assemble, and can be used in experiments or project works in physics teaching laboratories at the undergraduate level.

  14. Proceedings of the Flat-Plate Solar Array Project Research Forum on Photovoltaic Metallization Systems

    NASA Technical Reports Server (NTRS)

    1983-01-01

    A photovoltaic Metallization Research forum, under the sponsorship of the Flat-Plate Solar Array Project consisted of five sessions, covering: (1) the current status of metallization systems, (2) system design, (3) thick-film metallization, (4) advanced techniques, and (5) future metallization challenges.

  15. Design of Stress-Strain Measuring System for Bulldozing Plate Based on Virtual Instrument Technology

    NASA Astrophysics Data System (ADS)

    Xu, S. C.; Li, J. Q.; Zhang, R.

    2006-10-01

    Soil is a kind of discrete, multiphase compound that is composed of soil particles, liquid and air. When soil is disturbed by bulldozing plate, the mechanical behavior of the soil will become very complex. Based on the law of action and reaction, the dynamic mechanical behavior of disturbed soil was indirectly analyzed by measuring and studying the forces on the bulldozing plate by soil currently, so a stress-strain virtual measuring system for bulldozing plate, which was designed by the graphical programming language DASYLab, was used to measure the horizontal force Fz acting on the bulldozing plate. In addition, during the course of design, the experimental complexities and the interferential factors influencing on signal logging were analyzed when bulldozing plate worked, so the anti-jamming methods of hardware and software technology were adopted correlatively. In the end, the horizontal force Fz was analyzed with Error Theory, the result shown that the quantificational analysis of Fz were identical to the qualitative results of soil well, and the error of the whole test system is under 5 percent, so the tress-strain virtual measuring system was stable and credible.

  16. Evaluation of the flat-plate solar collector system for electric power generation

    NASA Technical Reports Server (NTRS)

    Athey, R. E.

    1976-01-01

    This evaluation of the flat-plate collector system was designed to determine the number of flat-plate collectors required to generate a given amount of electricity with optimum efficiency. Variable parameters are the temperature of the heat-transport fluid, both to and from the collector field. In the analysis, the efficiency of the flat-plate collectors was coupled to the efficiency of the thermal cycle to calculate optimal overall system efficiencies. Overall system efficiencies for the system are on the order of 3.5 per cent or less. Over two million 4 ft-by-4 ft collectors would be required to produce 100,000 kW(e). Based on the results, it can be shown that the limiting factor in the use of the flat-plate collector system for electric power generation is the efficiency of the collectors. An increase in the overall system efficiency can occur only if the collector efficiency can be increased at higher surface temperatures.

  17. Flate-plate photovoltaic power systems handbook for Federal agencies

    NASA Technical Reports Server (NTRS)

    Cochrane, E. H.; Lawson, A. C.; Savage, C. H.

    1984-01-01

    The primary purpose is to provide a tool for personnel in Federal agencies to evaluate the viability of potential photovoltaic applications. A second objective is to provide descriptions of various photovoltaic systems installed by different Federal agencies under the Federal Photovoltaic Utilization Program so that other agencies may consider similar applications. A third objective is to share lessons learned to enable more effective procurement, design, installation, and operation of future photovoltaic systems. The intent is not to provide a complete handbook, but rather to provide a guide for Federal agency personnel with additional information incorporated by references. The steps to be followed in selecting, procuring, and installing a photovoltaic application are given.

  18. One plate, two plates, a thousand plates. How crystallisation changes with large numbers of samples.

    PubMed

    Newman, Janet

    2011-09-01

    Turning commercial lab automation into a high-throughput centre requires an underlying process, and implementing checks to ensure that the process is working as it should. At the Collaborative Crystallisation Centre (C3), protein samples from local, national and international groups are set up in crystallisation screening and optimisation experiments with two thousand 96 well plates being set up each year. During its five years of operation, the C3 has implemented a series of enabling protocols - from simple 'reality checks' to determine if a screen has evaporated during storage to more sophisticated systems such as a sample labelling and tracking system. The most important - and perhaps surprising - lesson has been how much effort is required to effectively communicate between the centre and its clients, as well as between the centre's staff members. It is easy to confuse the concept of 'high throughput' in any field with the idea of setting up an experiment quickly. Although automation can be used to set up a single experiment more rapidly than can be done by hand, the distinguishing feature of a high throughput technology is the sustainability of the increased rate. PMID:21571072

  19. VAPI: low-cost, rapid automated visual inspection system for Petri plate analysis

    NASA Astrophysics Data System (ADS)

    Chatburn, L. T.; Kirkup, B. C.; Polz, M. F.

    2007-09-01

    Most culture-based microbiology tasks utilize a petri plate during processing, but rarely do the scientists capture the full information available from the plate. In particular, visual analysis of plates is an under-developed rich source of data that can be rapid and non-invasive. However, collecting this data has been limited by the difficulties of standardizing and quantifying human observations, by the limits of a scientists' fatigue, and by the cost of automating the process. The availability of specialized counting equipment and intelligent camera systems has not changed this - they are prohibitively expensive for many laboratories, only process a limited number of plate types, are often destructive to the sample, and have limited accuracy. This paper describes an automated visual inspection solution, VAPI, that employs inexpensive consumer computing hardware and digital cameras along with custom cross-platform open-source software written in C++, combining Trolltech's Qt GUI toolkit with Intel's OpenCV computer vision library. The system is more accurate than common commercial systems costing many times as much, while being flexible in use and offering comparable responsiveness. VAPI not only counts colonies but also sorts and enumerates colonies by morphology, tracks colony growth by time series analysis, and provides other analytical resources. Output to XML files or directly to a database provides data that can be easily maintained and manipulated by the end user, offering ready access for system enhancement, interaction with other software systems, and rapid development of advanced analysis applications.

  20. Control design and robustness analysis of a ball and plate system by using polynomial chaos

    SciTech Connect

    Colón, Diego; Balthazar, José M.; Reis, Célia A. dos; Bueno, Átila M.; Diniz, Ivando S.; Rosa, Suelia de S. R. F.

    2014-12-10

    In this paper, we present a mathematical model of a ball and plate system, a control law and analyze its robustness properties by using the polynomial chaos method. The ball rolls without slipping. There is an auxiliary robot vision system that determines the bodies' positions and velocities, and is used for control purposes. The actuators are to orthogonal DC motors, that changes the plate's angles with the ground. The model is a extension of the ball and beam system and is highly nonlinear. The system is decoupled in two independent equations for coordinates x and y. Finally, the resulting nonlinear closed loop systems are analyzed by the polynomial chaos methodology, which considers that some system parameters are random variables, and generates statistical data that can be used in the robustness analysis.

  1. Control design and robustness analysis of a ball and plate system by using polynomial chaos

    NASA Astrophysics Data System (ADS)

    Colón, Diego; Balthazar, José M.; dos Reis, Célia A.; Bueno, Átila M.; Diniz, Ivando S.; de S. R. F. Rosa, Suelia

    2014-12-01

    In this paper, we present a mathematical model of a ball and plate system, a control law and analyze its robustness properties by using the polynomial chaos method. The ball rolls without slipping. There is an auxiliary robot vision system that determines the bodies' positions and velocities, and is used for control purposes. The actuators are to orthogonal DC motors, that changes the plate's angles with the ground. The model is a extension of the ball and beam system and is highly nonlinear. The system is decoupled in two independent equations for coordinates x and y. Finally, the resulting nonlinear closed loop systems are analyzed by the polynomial chaos methodology, which considers that some system parameters are random variables, and generates statistical data that can be used in the robustness analysis.

  2. Present-day plate motions: Retrieval from the TOPEX/Poseidon orbitography network (DORIS system)

    NASA Technical Reports Server (NTRS)

    Souriau, Annie; Cazenave, Anny; Biancale, R.; Balmino, G.; Dominh, K.; Mazzega, P.; Lemoine, J.-M.; Boucher, Claude; Willis, P.; Kasser, M.

    1991-01-01

    The goal of the proposal is to determine the present motion of the main tectonic plates from the Doppler data of the Doppler Orbitography and Radiopositioning Integrated by Satellite (DORIS) orbitography system, which includes in its final configuration about 50 tracking stations with a world-wide distribution.

  3. The effect of surface roughness on the adhesion of elastic plates with application to biological systems

    NASA Astrophysics Data System (ADS)

    Persson, B. N. J.; Gorb, S.

    2003-12-01

    We study the influence of surface roughness on the adhesion of elastic plates. Most real surfaces have roughness on many different length scales, and this fact is taken into account in our analysis. We consider in detail the case when the surface roughness can be described as a self-affine fractal, and study the plate-substrate pull-off force as a function of the surface roughness. Based on the theoretical results we discuss adhesion in biological systems, focusing on the adhesive pads of lizards.

  4. Plate coil thermal test bench for the Daniel K. Inouye Solar Telescope (DKIST) carousel cooling system

    NASA Astrophysics Data System (ADS)

    Phelps, LeEllen; Murga, Gaizka; Montijo, Guillermo; Hauth, David

    2014-08-01

    Analyses have shown that even a white-painted enclosure requires active exterior skin-cooling systems to mitigate dome seeing which is driven by thermal nonuniformities that change the refractive index of the air. For the Daniel K. Inouye Solar Telescope (DKIST) Enclosure, this active surface temperature control will take the form of a system of water cooled plate coils integrated into the enclosure cladding system. The main objective of this system is to maintain the surface temperature of the enclosure as close as possible to, but always below, local ambient temperature in order to mitigate this effect. The results of analyses using a multi-layer cladding temperature model were applied to predict the behavior of the plate coil cladding system and ultimately, with safety margins incorporated into the resulting design thermal loads, the detailed designs. Construction drawings and specifications have been produced. Based on these designs and prior to procurement of the system components, a test system was constructed in order to measure actual system behavior. The data collected during seasonal test runs at the DKIST construction site on Haleakalā are used to validate and/or refine the design models and construction documents as appropriate. The test fixture was also used to compare competing hardware, software, components, control strategies, and configurations. This paper outlines the design, construction, test protocols, and results obtained of the plate coil thermal test bench for the DKIST carousel cooling system.

  5. Measurements of Conversion Efficiency for a Flat Plate Thermophotovoltaic System Using a Photonic Cavity Test System

    SciTech Connect

    E.J. Brown; C.T. Ballinger; S.R. Burger; G.W. Charache; L.R. Danielson; D.M. DePoy; T.J. Donovan; M. LoCascio

    2000-05-30

    The performance of a 1 cm{sup 2} thermophotovoltaic (TPV) module was recently measured in a photonic cavity test system. A conversion efficiency of 11.7% was measured at a radiator temperature of 1076 C and a module temperature of 29.9 C. This experiment achieved the highest direct measurement of efficiency for an integrated TPV system. Efficiency was calculated from the ratio of the peak (load matched) electrical power output and the heat absorption rate. Measurements of these two parameters were made simultaneously to assure the validity of the measured efficiency value. This test was conducted in a photonic cavity which mimicked a typical flat-plate TPV system. The radiator was a large, flat graphite surface. The module was affixed to the top of a copper pedestal for heat absorption measurements. The heat absorption rate was proportional to the axial temperature gradient in the pedestal under steady-state conditions. The test was run in a vacuum to eliminate conductive and convective heat transfer mechanisms. The photonic cavity provides the optimal test environment for TPV efficiency measurements because it incorporates all important physical phenomena found in an integrated TPV system: high radiator emissivity and blackbody spectral shape, photon recycling, Lambertian distribution of incident radiation and complex geometric effects. Furthermore, the large aspect ratio between radiating surface area and radiator/module spacing produces a view factor approaching unity with minimal photon leakage.

  6. Proceedings of the flat-plate solar array project research forum on photovoltaic metallization systems

    SciTech Connect

    1983-11-15

    A Photovoltaic Metallization Research Forum, under the sponsorship of the Jet Propulsion Laboratory's Flat-Plate Solar Array Project and the US Department of Energy, was held March 16-18, 1983 at Pine Mountain, Georgia. The Forum consisted of five sessions, covering (1) the current status of metallization systems, (2) system design, (3) thick-film metallization, (4) advanced techniques and (5) future metallization challenges. Twenty-three papers were presented.

  7. Optimum design of bipolar plates for separate air flow cooling system of PEM fuel cells stacks

    NASA Astrophysics Data System (ADS)

    Franco, Alessandro

    2015-12-01

    The paper discusses about thermal management of PEM fuel cells. The objective is to define criteria and guidelines for the design of the air flow cooling system of fuel cells stacks for different combination of power density, bipolar plates material, air flow rate, operating temperature It is shown that the optimization of the geometry of the channel permits interesting margins for maintaining the use of separate air flow cooling systems for high power density PEM fuel cells.

  8. A neural network based artificial vision system for licence plate recognition.

    PubMed

    Draghici, S

    1997-02-01

    This paper presents a neural network based artificial vision system able to analyze the image of a car given by a camera, locate the registration plate and recognize the registration number of the car. The paper describes in detail various practical problems encountered in implementing this particular application and the solutions used to solve them. The main features of the system presented are: controlled stability-plasticity behavior, controlled reliability threshold, both off-line and on-line learning, self assessment of the output reliability and high reliability based on high level multiple feedback. The system has been designed using a modular approach. Sub-modules can be upgraded and/or substituted independently, thus making the system potentially suitable in a large variety of vision applications. The OCR engine was designed as an interchangeable plug-in module. This allows the user to choose an OCR engine which is suited to the particular application and to upgrade it easily in the future. At present, there are several versions of this OCR engine. One of them is based on a fully connected feedforward artificial neural network with sigmoidal activation functions. This network can be trained with various training algorithms such as error backpropagation. An alternative OCR engine is based on the constraint based decomposition (CBD) training architecture. The system has showed the following performances (on average) on real-world data: successful plate location and segmentation about 99%, successful character recognition about 98% and successful recognition of complete registration plates about 80%. PMID:9228583

  9. Development of Portable Automatic Number Plate Recognition System on Android Mobile Phone

    NASA Astrophysics Data System (ADS)

    Mutholib, Abdul; Gunawan, Teddy S.; Chebil, Jalel; Kartiwi, Mira

    2013-12-01

    The Automatic Number Plate Recognition (ANPR) System has performed as the main role in various access control and security, such as: tracking of stolen vehicles, traffic violations (speed trap) and parking management system. In this paper, the portable ANPR implemented on android mobile phone is presented. The main challenges in mobile application are including higher coding efficiency, reduced computational complexity, and improved flexibility. Significance efforts are being explored to find suitable and adaptive algorithm for implementation of ANPR on mobile phone. ANPR system for mobile phone need to be optimize due to its limited CPU and memory resources, its ability for geo-tagging image captured using GPS coordinates and its ability to access online database to store the vehicle's information. In this paper, the design of portable ANPR on android mobile phone will be described as follows. First, the graphical user interface (GUI) for capturing image using built-in camera was developed to acquire vehicle plate number in Malaysia. Second, the preprocessing of raw image was done using contrast enhancement. Next, character segmentation using fixed pitch and an optical character recognition (OCR) using neural network were utilized to extract texts and numbers. Both character segmentation and OCR were using Tesseract library from Google Inc. The proposed portable ANPR algorithm was implemented and simulated using Android SDK on a computer. Based on the experimental results, the proposed system can effectively recognize the license plate number at 90.86%. The required processing time to recognize a license plate is only 2 seconds on average. The result is consider good in comparison with the results obtained from previous system that was processed in a desktop PC with the range of result from 91.59% to 98% recognition rate and 0.284 second to 1.5 seconds recognition time.

  10. β-Cyclodextrin enhanced on-line organic solvent field-amplified sample stacking in capillary zone electrophoresis for analysis of ambroxol in human plasma, following liquid-liquid extraction in the 96-well format.

    PubMed

    Li, Ji; Bi, Youwei; Wang, Li; Sun, Fanlu; Chen, Zhao; Xu, Guili; Fan, Guorong

    2012-07-01

    A field-amplified sample stacking (FASS) and capillary zone electrophoresis (CZE) method is described for the quantification of ambroxol hydrochloride in human plasma, following liquid-liquid extraction in the 96-well format. The separation was carried out at 25 °C in a 31.2 cm × 75 μm fused-silica capillary with an applied voltage of 15 kV. The background electrolyte (BGE) was composed of 6.25 mM borate-25 mM phosphate (pH 3.0) and 1mM β-cyclodextrin. The detection wavelength was 210 nm. Clean-up and preconcentration of plasma biosamples were developed by 96-well format liquid-liquid extraction (LLE). In this study, FASS in combination with β-cyclodextrin enhanced the sensitivity about 60-70 fold in total. The method was suitably validated with respect to stability, specificity, linearity, lower limit of quantitation, accuracy, precision, extraction recovery and robustness. The calibration graph was linear for ambroxol hydrochloride from 2 to 500 ng/ml. The lower limit of quantification was 2 ng/ml. The intra- and inter-day precisions of lowest limit of quantification (LLOQ) were 9.61 and 11.80%, respectively. The method developed was successfully applied to the evaluation of clinical pharmacokinetic study of ambroxol hydrochloride tablet after oral administration to 12 healthy volunteers. PMID:22464560

  11. Microtiter plate-based antibody microarrays for bacteria and toxins

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Research has focused on the development of rapid biosensor-based, high-throughput, and multiplexed detection of pathogenic bacteria in foods. Specifically, antibody microarrays in 96-well microtiter plates have been generated for the purpose of selective detection of Shiga toxin-producing E. coli (...

  12. Advanced Extended Plate and Beam Wall System in a Cold-Climate House

    SciTech Connect

    Mallay, Dave; Wiehagen, Joseph; Kochkin, Vladimir

    2016-01-01

    This report presents the design and evaluation of an innovative wall system. This highly insulated (high-R) light-frame wall system for use above grade in residential buildings is referred to as Extended Plate & Beam (EP&B). The EP&B design is the first of its kind to be featured in a new construction test house (NCTH) for the DOE Building America program. The EP&B wall design integrates standard building methods and common building products to construct a high-R wall that minimizes transition risks and costs to builders.

  13. Modular array field designs for tracking flat-plate photovoltaic systems, volume 1

    NASA Astrophysics Data System (ADS)

    Castle, J. A.

    1987-06-01

    This report addresses the optimization of utility-sized, tracking flat-plate photovoltaic power systems. Structures optimized were one single-axis and one dual-axis tracking system using currently available system designs as baseline engineering reference points. Passive thermal-hydraulic tracking drive systems were evaluated and Freon-hydraulic units were found to be cost-effective in single-axis tracking. Building block configurations ranging in size from 35 kW to 5 MW were established using the optimized single- and dual-axis tracking structures, and their reliability and availability were analyzed. A 1-MW single-axis building block design was selected to develop engineering plans for a 100-MW PV power plant designed to operate unattended. Eleven-percent efficient PV panels at $220/sq m were used in the study, and single-axis, flat-plate tracking systems were found to be significantly more cost-effective than dual-axis systems. A prototype tracking array was built and tested at Sandia, where cost and performance data supported lower economic projections for large PV tracking arrays.

  14. Development of a System to Measure Recrystallization Ratio of Plate Steel Using Laser-Based Ultrasonics

    SciTech Connect

    Nagata, Y.; Yamada, H.; Hamada, N.; Lim, C. S.; Yi, J. K.; Hong, S. T.; Choi, S. G.; Oh, K. J.

    2007-03-21

    In this study, a material property measurement system of plate steel using laser-based ultrasonics has been developed. The system consists of pulsed Nd:YAG laser for ultrasonic generation, CW single frequency laser and Fabry-Perot interferometer for ultrasonic detection. The system generates and detects shear waves and precisely calculates anisotropy parameter values of shear wave velocities of test samples. At first, the relationship between anisotropy parameter and recrystallization ratio was investigated in the laboratory experiments. Quenching the test samples just after the ultrasonic measurement, recrystallization ratio values were measured by the conventional microscopic method. According to the experimental results, the anisotropy parameter values showed a good correlation with actual recrystallization ratio values. To evaluate the applicability of the system to real steel production line, the system was installed in hot rolling pilot plant of plate steel. As the results, it was demonstrated that the system could measure the recrystallization ratio using the anisotropy parameter values of shear wave velocities, even in the environment of hot rolling pilot plant.

  15. Review of 31 cases of anterior thoracolumbar fixation with the anterior thoracolumbar locking plate system.

    PubMed

    Wilson, J A; Bowen, S; Branch, C L; Meredith, J W

    1999-07-15

    Anterior fixation devices for the thoracolumbar spine have gained wide acceptance as viable alternatives to long-segment posterior fixation in cases of thoracolumbar spine trauma. This review was undertaken to evaluate the safety and efficacy of the Synthes anterior thoracolumbar locking plate (ATLP) system. Over a 3-year period, 31 patients with unstable traumatic fractures of the thoracolumbar spine underwent corpectomy, placement of a structural bone graft, and anterior fixation in which the Synthes ATLP system was used. Long-term follow-up data were obtained in 29 patients. Two patients were lost to follow up, one at 4 months and the other at 1 year. In the remaining patients, the average length of follow up was 20 months. In all patients radiographic evidence of solid bone fusion was demonstrated on follow-up plain x-ray films, and there were no signs or symptoms of pseudarthrosis. No patient suffered neurological deterioration as a result of surgery, and there was relatively little morbidity associated with this plating system. To date, none of the patients in this study has developed any delayed complications related to the fixation device. In one patient, who had sustained a severe flexion injury, loosening of the anterior fixation device occurred, and the patient developed progressive kyphosis, which required a posterior stabilization procedure. These results appear slightly better than those obtained in published studies in which other anterior plating systems were used, indicating that this system is safe and effective in the treatment of unstable fractures of the thoracolumbar spine. PMID:16918232

  16. PERPENDICULAR DOUBLE-PLATE FIXATION WITH LOCKING SYSTEM FOR ACROMION PEDICLE FRACTURE

    PubMed Central

    Zhu, Junkun; Pan, Zhijun; Zheng, Rongzong; Lan, Shuhua

    2016-01-01

    Objective : To describe the surgical technique and preliminary clinical outcomes in a series of open reduction internal fixation of basal acromion process fractures applying a double-plating technique. Methods : Nine consecutive patients, mean age 33.4 years old (range, 23-61 years old) with unilateral acromion fracture (Type 3 AO/OTA) with more than 1cm displacement who underwent fixation utilizing a locked double-plating technique, were evaluated on average at 7.8 months (range, 3-15 months) for outcomes related to pain, shoulder function, and surgical complications. Results : Eight patients recovered with complete radiographic union and favorable shoulder function. One case failed to be fully evaluated for more than 3 months follow-up. The overall scores of Constant, Shoulder Pain and Disability Index (SPADI) and DASH for the eight patients reviewed were 91.9± 6.31, 3.11± 3.79 and 5.2± 6.35, respectively. No post-operative infection or surgical hardware irritation was identified at final follow-up of these eight patients. Conclusion : While more evidence is needed to justify its advantages over traditional implants, perpendicular double-plate with a locking system may be indicated for acromion pedicle fracture treatment, since it performed well for fracture healing and joint function rehabilitation. Level of Evidence IV, Therapeutic Study. PMID:26981047

  17. Seismotectonics of the eastern Himalayan and indo-burman plate boundary systems

    NASA Astrophysics Data System (ADS)

    Kumar, Ajay; Mitra, Supriyo; Suresh, G.

    2015-11-01

    The eastern Himalayan and Indo-Burman plate boundary systems are distinct from the rest of the India-Eurasia continental collision, due to oblique convergence across two orthogonal plate boundaries resulting in a zone of distributed deformation both within and away from the plate boundary. To understand the seismotectonics of this region, we model the source mechanism of 44 earthquakes using waveform inversion and combine them with source mechanism of 30 previously studied earthquakes. Depth distribution of these earthquakes reveal that the entire crust beneath northeast India is seismogenic. From spatial distribution and source mechanism it is evident that the N20°E convergence between India and Tibet is accommodated by N-S convergence and E-W subduction. The N-S convergence is accommodated through (a) shallow thrust earthquakes within the eastern Himalayan wedge, (b) lower crustal thrust earthquakes along the northern edge of Shillong Plateau, (c) lower crustal dextral strike-slip earthquakes in the Kopili fault zone, and (d) sinistral strike-slip earthquakes within the Bengal Basin crust. The E-W subduction results in shallow thrust earthquakes to intermediate depth strike-slip earthquakes and deep focus thrust earthquakes underneath the Indo-Burman convergence zone. Orientation of the fault plane and slip vectors point to downdip extension and along arc compression of the subducted Indian plate in response to slab pull forces and buckling at depth. Earthquake slip vectors are in good agreement with the GPS velocity vectors across northeast India and conforms to the clockwise rotating "microplates" model.

  18. Parametric synthesis of optical systems composed of thin lenses by using the plane-parallel plate aberration properties

    NASA Astrophysics Data System (ADS)

    Ezhova, Kseniia; Zverev, Victor; Ezhova, Vasilisa

    2015-09-01

    The possibility of constructing the optical system with an aplanatic correction of aberrations representing generally combination of the thin lens with an aplanatic meniscus and plane-parallel plate of small thickness is shown.

  19. Zone plate tilt study in transmission x-ray microscope system at 8-11 keV

    NASA Astrophysics Data System (ADS)

    Chao, Fu-Han; Yin, Gung-Chian; Liang, Keng S.; Lai, Yin-Chieh

    2009-08-01

    Zone plate [1] has been used as a focal lens in transmission X-ray microscope (TXM) optical system in recent decades [2, 3]. In TXM of NSRRC[4,5], the thickness of zone plate is about 900nm and the width of its out most zones is 50nm, which has a high aspect ratio 18. When zone plate is tilted, the image quality will be affected by aberration. Since the aspect ratio of zone plate is large, for incident beam, the shape of zone plate's transmission function will look different when zone plate is tilted. The both experimental and simulation result will be shown in this present. A five axes stage is designed and manufactured for the zone plate holder for three dimensional movement, tip and tilt. According to Fourier theory, we can calculate the wave distribution on image plane, if we know the original wave function, the distances between each element, and the transparencies of the sample and zone plate. A parallel simulation process code in MATLAB is developed in workstation cluster with up to 128Gbytes memory. The effects of aberration generated by tilt effect are compared from the experimental data and simulation result. A maximum tilt angle within the acceptable image quality is calculated by simulation and will be verified by experiment.

  20. Fractional Order and Dynamic Simulation of a System Involving an Elastic Wide Plate

    NASA Astrophysics Data System (ADS)

    David, S. A.; Balthazar, J. M.; Julio, B. H. S.; Oliveira, C.

    2011-09-01

    Numerous researchers have studied about nonlinear dynamics in several areas of science and engineering. However, in most cases, these concepts have been explored mainly from the standpoint of analytical and computational methods involving integer order calculus (IOC). In this paper we have examined the dynamic behavior of an elastic wide plate induced by two electromagnets of a point of view of the fractional order calculus (FOC). The primary focus of this study is on to help gain a better understanding of nonlinear dynamic in fractional order systems.

  1. A Protein Concentration Measurement System Using a Flexural Plate-Wave Frequency-Shift Readout Technique

    PubMed Central

    Wang, Chua-Chin; Sung, Tzu-Chiao; Hsu, Chia-Hao; Tsai, Yue-Da; Chen, Yun-Chi; Lee, Ming-Chih; Huang, I-Yu

    2013-01-01

    A protein concentration measurement system with two-port flexural plate-wave (FPW) biosensors using a frequency-shift readout technique is presented in this paper. The proposed frequency-shift readout method employs a peak detecting scheme to measure the amount of resonant frequency shift. The proposed system is composed of a linear frequency generator, a pair of peak detectors, two registers, and a subtractor. The frequency sweep range of the linear frequency generator is limited to 2 MHz to 10 MHz according to the characteristics of the FPW biosensors. The proposed frequency-shift readout circuit is carried out on silicon using a standard 0.18 μm CMOS technology. The sensitivity of the peak detectors is measured to be 10 mV. The power consumption of the proposed protein concentration measurement system is 48 mW given a 0.1 MHz system clock. PMID:23344375

  2. Korean Type Distal Radius Anatomical Volar Plate System: A Preliminary Report

    PubMed Central

    Kim, Jeong Hwan; Kim, Jihyeung; Kim, Min Bom; Rhee, Seung Hwan; Gong, Hyun Sik; Lee, Young Ho

    2014-01-01

    Background Distal radius fracture is the most common fracture of the upper extremity, and approximately 60,000 distal radius fractures occur annually in Korea. Internal fixation with an anatomical volar locking plate is widely used in the treatment of unstable distal radius fractures. However, most of the currently used distal radius anatomical plate systems were designed based on the anatomical characteristics of Western populations. Recently, the Korean-type distal radius anatomical volar plate (K-DRAVP) system was designed and developed based on the anatomical characteristics of the distal radius of Koreans. The purpose of this study was to evaluate the preliminary results of the new K-DRAVP system, and to compare its radiologic and functional results with those of the other systems. Methods From March 2012 to October 2012, 46 patients with acute distal radius fractures who were treated with the K-DRAVP system at three hospitals were enrolled in this study. Standard posteroanterior and lateral radiographs were obtained to assess fracture healing, and three radiographic parameters (volar tilt, radial inclination, and radial length) were assessed to evaluate radiographic outcomes. The range of motion and grip strength, the Gartland and Werley scoring system, and the disabilities of the arm, shoulder and hand (DASH) questionnaire were used to assess clinical and functional outcomes. Results All radiologic parameters were restored to normal values, and maintained without any loosening or collapse until the time of final follow-up. Grip strength was restored to 84% of the value for the unaffected side. The mean range of motion of the wrist at final follow-up was restored to 77%-95% of the value for the unaffected side. According to the Gartland and Werley scoring system, there were 16 excellent, 26 good, and 4 fair results. The mean DASH score was 8.4 points. There were no complications after surgery. Conclusions The newly developed K-DRAVP system could be used to

  3. Enrichment of circulating tumor cells using a centrifugal affinity plate system.

    PubMed

    Lee, Sung-Woo; Hyun, Kyung-A; Kim, Seung-Il; Kang, Ji-Yoon; Jung, Hyo-Il

    2014-12-19

    Circulating tumor cells (CTCs) are defined as cells that have detached from a primary tumor and are circulating in the bloodstream. Their isolation and quantification is of great value for cancer prognoses and drug testing. Here, the development of a centrifugal affinity plate (CAP) system is described, in which centrifugal force and antibody-based capture are exploited to enrich CTCs on one plate and hematological cells on the other. The CAP is rotated to exert centrifugal force on the cells in a blood sample, quickly transporting them to the anti-epithelial adhesion molecule (EpCAM)-coated and anti-CD45-coated surface of the CAP to shorten the reaction time and increase the adhesion force between the tumor and blood cells and each antibody. The effect of a rotating process on cell capture was investigated, and the capture efficiency was demonstrated using blood samples from healthy donors spiked with human non-small cell lung cancer (NCI-H1650) and breast cancer (MCF-7) cells. The CAP system was capable of rapid isolation and identification of CTCs without the requirement for pretreatment of blood samples. Finally, the CAP system was tested to evaluate the detection efficiency of CTCs in the blood samples of breast cancer patients. The number of captured CTCs in only 1ml of blood varied from 6 to 10. PMID:25435456

  4. Application of an imaging plate system to the direct measurement of a fixed surface contamination.

    PubMed

    Hirota, Masahiro; Kimura, Keiji; Sato, Rumi; Koike, Yuya; Iimoto, Takeshi; Tanaka, Satoru

    2014-08-01

    An imaging plate (IP) system was used as an effective detector for direct measurement of radioactive surface contamination. The IP system displayed images designating the locations and extent of fixed surface contamination of uranyl acetate. The amount of radioactive waste produced during decontamination was reduced because the contaminated spots could be isolated; furthermore, creation of radioactive dust during removal of contamination was prevented because the contaminated spots could be removed without being pulverized. The images were used in efficiently and safely isolating the location of fixed surface contamination. The IP system surface contamination detection limit for uranyl acetate was 2.5 × 10 Bq cm, a value much lower than the surface contamination limit and the clearance level. PMID:24978288

  5. Cooled electronic system with liquid-cooled cold plate and thermal spreader coupled to electronic component

    DOEpatents

    Chainer, Timothy J.; Graybill, David P.; Iyengar, Madhusudan K.; Kamath, Vinod; Kochuparambil, Bejoy J.; Schmidt, Roger R.; Steinke, Mark E.

    2016-04-05

    Apparatus and method are provided for facilitating cooling of an electronic component. The apparatus includes a liquid-cooled cold plate and a thermal spreader associated with the cold plate. The cold plate includes multiple coolant-carrying channel sections extending within the cold plate, and a thermal conduction surface with a larger surface area than a surface area of the component to be cooled. The thermal spreader includes one or more heat pipes including multiple heat pipe sections. One or more heat pipe sections are partially aligned to a first region of the cold plate, that is, where aligned to the surface to be cooled, and partially aligned to a second region of the cold plate, which is outside the first region. The one or more heat pipes facilitate distribution of heat from the electronic component to coolant-carrying channel sections of the cold plate located in the second region of the cold plate.

  6. Cooled electronic system with liquid-cooled cold plate and thermal spreader coupled to electronic component

    DOEpatents

    Chainer, Timothy J.; Graybill, David P.; Iyengar, Madhusudan K.; Kamath, Vinod; Kochuparambil, Bejoy J.; Schmidt, Roger R.; Steinke, Mark E.

    2016-08-09

    Apparatus and method are provided for facilitating cooling of an electronic component. The apparatus includes a liquid-cooled cold plate and a thermal spreader associated with the cold plate. The cold plate includes multiple coolant-carrying channel sections extending within the cold plate, and a thermal conduction surface with a larger surface area than a surface area of the component to be cooled. The thermal spreader includes one or more heat pipes including multiple heat pipe sections. One or more heat pipe sections are partially aligned to a first region of the cold plate, that is, where aligned to the surface to be cooled, and partially aligned to a second region of the cold plate, which is outside the first region. The one or more heat pipes facilitate distribution of heat from the electronic component to coolant-carrying channel sections of the cold plate located in the second region of the cold plate.

  7. Plate boundary and major fault system in the overriding plate within the Shumagin gap at the Alaska-Aleutian subduction zone

    NASA Astrophysics Data System (ADS)

    Becel, A.; Shillington, D. J.; Nedimovic, M. R.; Keranen, K. M.; Li, J.; Webb, S. C.; Kuehn, H.

    2013-12-01

    Structure in the overriding plate is one of the parameters that may increase the tsunamigenic potential of a subduction zone but also influence the seismogenic behavior and segmentation of great earthquake rupture. The Alaska-Aleutian margin is characterized by along-strike changes in plate interface coupling over relatively small distances. Here, we present trench normal multichannel seismic (MCS) profiles acquired across the Shumagin gap that has not broken in many decades and appears to be weakly coupled. The high fold, deep penetration (636 channel, 8-km long streamer, 6600 cu.in airgun source) MCS data were acquired as part of the ALEUT project. This dataset gives us critical new constraints on the interplate boundary that can be traced over ~100 km distance beneath the forearc with high variation in its reflection response with depth. These profiles also reveal the detailed upper plate fault structure and forearc morphology. Clear reflections in the overriding plate appear to delineate one or more large faults that cross the shelf and the upper slope. These faults are observed 75 km back from the trench and seem to branch at depth and connect to the plate interface within this gap at ~11 s twtt. We compare the reflective structure of these faults to that of the plate boundary and examine where it intersects the megathrust with respect of the expected downdip limit of coupling. We also compare this major structure with the seismicity recorded in this sector. The imaged fault system is associated with a large deep basin (~6s twt) that is an inherited structure formed during the pre-Aleutian period. Basins faults appear to have accommodated primarily normal motion, although folding of sediments near the fault and complicated fault geometries in the shallow section may indicate that this fault has accommodated other types of motion during its history that may reflect the stress-state at the megathrust over time. The deformation within the youngest sediment also

  8. A Serial Sample Loading System: Interfacing Multi-well plates with Microfluidic Devices

    PubMed Central

    Rane, Tushar D.; Zec, Helena; Wang, Jeff Tza-Huei

    2013-01-01

    There is an increasing demand for novel high-throughput screening (HTS) technologies in the pharmaceutical and biotechnological industries. The robotic sample handling techniques currently used in these industries, although fast, are still limited to operating in multi-well plates with the sample volumes per reaction in the microliter regime. Digital microfluidics offers an alternative for reduction in sample volume consumption for HTS but lacks a reliable technique for transporting large number of samples to the microfluidic device. In this report, we develop a technique for serial delivery of sample arrays to a microfluidic device from multi-well plates, through a single sample inlet. Under this approach, a serial array of sample plugs, separated by an immiscible carrier fluid, is loaded into a capillary and delivered to a microfluidic device. Similar approaches have been attempted in the past, however, either with a slower sample loading device like syringe pump or vacuum based sample loading with limited driving pressure. We demonstrated the application of our positive pressure based ‘Serial Sample Loading’ (SSL) system to load a series of sample plugs into a capillary. The adaptability of the SSL system to generate sample plugs with a variety of volumes in a predictable manner was also demonstrated. PMID:22885789

  9. Flat-plate boiloff calorimeters for testing of thermal insulation systems

    NASA Astrophysics Data System (ADS)

    Fesmire, J. E.; Johnson, W. L.; Kelly, A. O.; Meneghelli, B. J.; Swanger, A. M.

    2015-12-01

    Cryostats have been developed and standardized for laboratory testing of thermal insulation systems in a flat-plate configuration. Boiloff calorimetry is the measurement principle for determining the effective thermal conductivity (ke) and heat flux (q) of test specimens under a wide range of actual conditions. Cryostat-500 is thermally guarded to measure absolute thermal performance when calibrated with a known reference via an adjustable-edge guard ring. With liquid nitrogen as the energy meter, the cold boundary temperature can be adjusted to any temperature between 77 K and approximately 300 K by the interposition of a thermal resistance layer between the cold mass and the specimen. A low thermal conductivity suspension system has compliance rods that adjust for specimen thickness and compression force. Material type, thickness, density, flatness, compliance, outgassing, and temperature sensor placement are important test considerations, and edge effects and calibration techniques for the apparatus are crucial. Over the full vacuum pressure range, the thermal performance capability is nearly four orders of magnitude. The horizontal configuration provides key advantages over the vertical cylindrical cryostats for testing at ambient pressure conditions. Cryostat-500’s design and test methods, other flat-plate boiloff calorimeters, and results for select thermal insulation materials (composites, foams, aerogels) are discussed.

  10. Optomechanical design of near-null subaperture test system based on counter-rotating CGH plates

    NASA Astrophysics Data System (ADS)

    Li, Yepeng; Chen, Shanyong; Song, Bing; Li, Shengyi

    2014-09-01

    In off-axis subapertures of most convex aspheres, astigmatism and coma dominate the aberrations with approximately quadratic and linear increase as the off-axis distance increases. A pair of counter-rotating computer generated hologram (CGH) plates is proposed to generate variable amount of Zernike terms Z4 and Z6, correcting most of the astigmatism and coma for subapertures located at different positions on surfaces of various aspheric shapes. The residual subaperture aberrations are then reduced within the vertical range of measurement of the interferometer, which enables near-null test of aspheres flexibly. The alignment tolerances for the near-null optics are given with optomechanical analysis. Accordingly a novel design for mounting and aligning the CGH plates is proposed which employs three concentric rigid rings. The CGH plate is mounted in the inner ring which is supported by two couples of ball-end screws in connection with the middle ring. The CGH plate along with the inner ring is hence able to be translated in X-axis and tipped by adjusting the screws. Similarly the middle ring is able to be translated in Y-axis and tilted by another two couples of screws orthogonally arranged and connected to the outer ring. This design is featured by the large center-through hole, compact size and capability of four degrees-of-freedom alignment (lateral shift and tip-tilt). It reduces the height measured in the direction of optical axis as much as possible, which is particularly advantageous for near-null test of convex aspheres. The CGH mounts are then mounted on a pair of center-through tables realizing counter-rotation. Alignment of the interferometer, the CGHs, the tables and the test surface is also discussed with a reasonable layout of the whole test system. The interferometer and the near-null optics are translated by a three-axis stage while the test mirror is rotated and tilted by two rotary tables. Experimental results are finally given to show the near

  11. A plate-driven model for enigmatic volcanic history of the Cascades-Yellowstone System

    NASA Astrophysics Data System (ADS)

    Szwaja, S.; Kincaid, C. R.; Druken, K. A.; MacDougall, J.

    2013-12-01

    The Cascades subduction system in the Pacific Northwest (USA) represents a complex tectonic setting, where rollback subduction of the Juan de Fuca plate beneath the North American plate, back-arc extension, and a possible mantle plume have been proposed to explain the complicated volcanic trends observed over the past 20 Ma. Plume and non-plume models have been developed to reconcile the voluminous Columbia River/Steens Flood Basalts (CSFB) (~20 Ma), the age progressive (15 Ma to present) Snake River Plain (SRP) that terminates at Yellowstone and the opposite, or westward trending High Lava Plains (HLP) volcanic track of eastern/central Oregon. We present results from laboratory experiments designed to test a plate-driven model for reproducing gross spatial-temporal characteristics of these three magmatic features. Models use a glucose fluid with temperature dependent viscosity in representing Earth's mantle and continuous rubber belts that kinematically reproduce subduction trends for the Cascades system. Experiments begin at 20 Ma with a volume of mantle residuum in the Cascades wedge that is elongated and restricted in the trench-parallel and trench-normal directions, respectively. The underlying assumption is that residuum was created in the wedge during an earlier plate steepening event that caused the flood basalts. Our models characterize dispersion patterns for the melt residuum material as it deforms within four-dimensional wedge circulation fields driven by rollback subduction (e.g. with a translational component of motion). Results show that residuum viscosity, relative to the ambient fluid, determines whether anomalous fluid can evolve to a morphology that matches the SRP/HLP tracks over ~15-20Ma. A weak residuum (e.g. retained partial melt) deforms over this time scale from the initial north-south oriented feature to an east-west trending morphology that is thin in both depth and north-south extent, material initially beneath CSFB is offset to the

  12. Stand-alone flat-plate photovoltaic power systems: System sizing and life-cycle costing methodology for Federal agencies

    NASA Technical Reports Server (NTRS)

    Borden, C. S.; Volkmer, K.; Cochrane, E. H.; Lawson, A. C.

    1984-01-01

    A simple methodology to estimate photovoltaic system size and life-cycle costs in stand-alone applications is presented. It is designed to assist engineers at Government agencies in determining the feasibility of using small stand-alone photovoltaic systems to supply ac or dc power to the load. Photovoltaic system design considerations are presented as well as the equations for sizing the flat-plate array and the battery storage to meet the required load. Cost effectiveness of a candidate photovoltaic system is based on comparison with the life-cycle cost of alternative systems. Examples of alternative systems addressed are batteries, diesel generators, the utility grid, and other renewable energy systems.

  13. On performance of an oscillating plate underwater propulsion system with variable chordwise flexibility at different depths of submergence

    NASA Astrophysics Data System (ADS)

    Barannyk, Oleksandr; Buckham, Bradley J.; Oshkai, Peter

    2012-01-01

    In this work, an oscillating plate propulsor undergoing a combination of heave translation and pitch rotation is investigated experimentally. The oscillation kinematics are inspired by swimming mechanisms employed by fish and other marine animals. The primary focus was on the propulsive characteristics of such oscillating plates, which were studied by means of direct force measurements in the thrust-producing regime. Experiments were performed at constant Reynolds number and constant heave amplitude. By varying the Strouhal number, the depth of submergence and the chordwise flexibility of the plate, it was possible to investigate corresponding changes in the generated thrust and the hydromechanical efficiency. It was possible to establish a set of parameters, including the driving frequency of the system, the ratio of rigid to flexible segment length of the plate, and the range of Strouhal numbers that led to an overall increase in thrust and efficiency. The experiments, involving plates with various ratios of rigid to flexible segment lengths, showed that greater flexibility increased the propulsive efficiency and thrust compared to an identical motion of the purely rigid plate. By submerging the plate at different depths, it was observed that the proximity of the propulsor to the bottom of the channel led to an overall increase in the thrust coefficient across the oscillation frequencies considered. The flow visualization revealed the formation of large dynamic stall vortices that influenced the wake structure, and suggested that their constructive interaction with trailing edge vortices might lead to overall improvement of thrust and efficiency.

  14. Compact three-dimensional head-mounted display system with Savart plate.

    PubMed

    Lee, Chang-Kun; Moon, Seokil; Lee, Seungjae; Yoo, Dongheon; Hong, Jong-Young; Lee, Byoungho

    2016-08-22

    We propose three-dimensional (3D) head-mounted display (HMD) providing multi-focal and wearable functions by using polarization-dependent optical path switching in Savart plate. The multi-focal function is implemented as micro display with high pixel density of 1666 pixels per inches is optically duplicated in longitudinal direction according to the polarization state. The combination of micro display, fast switching polarization rotator and Savart plate retains small form factor suitable for wearable function. The optical aberrations of duplicated panels are investigated by ray tracing according to both wavelength and polarization state. Astigmatism and lateral chromatic aberration of extraordinary wave are compensated by modification of the Savart plate and sub-pixel shifting method, respectively. To verify the feasibility of the proposed system, a prototype of the HMD module for monocular eye is implemented. The module has the compact size of 40 mm by 90 mm by 40 mm and the weight of 131 g with wearable function. The micro display and polarization rotator are synchronized in real-time as 30 Hz and two focal planes are formed at 640 and 900 mm away from eye box, respectively. In experiments, the prototype also provides augmented reality function by combining the optically duplicated panels with a beam splitter. The multi-focal function of the optically duplicated panels without astigmatism and color dispersion compensation is verified. When light field optimization for two additive layers is performed, perspective images are observed, and the integration of real world scene and high quality 3D images is confirmed. PMID:27557230

  15. Finite Element Analysis of a New Pedicle Screw-Plate System for Minimally Invasive Transforaminal Lumbar Interbody Fusion

    PubMed Central

    Zhou, Yue; Li, Changqing; Liu, Huan

    2015-01-01

    Purpose Minimally invasive transforaminal lumbar interbody fusion (MI-TLIF) is increasingly popular for the surgical treatment of degenerative lumbar disc diseases. The constructs intended for segmental stability are varied in MI-TLIF. We adopted finite element (FE) analysis to compare the stability after different construct fixations using interbody cage with posterior pedicle screw-rod or pedicle screw-plate instrumentation system. Methods A L3–S1 FE model was modified to simulate decompression and fusion at L4–L5 segment. Fixation modes included unilateral plate (UP), unilateral rod (UR), bilateral plate (BP), bilateral rod (BR) and UP+UR fixation. The inferior surface of the S1 vertebra remained immobilized throughout the load simulation, and a bending moment of 7.5 Nm with 400N pre-load was applied on the L3 vertebra to recreate flexion, extension, lateral bending, and axial rotation. Range of motion (ROM) and Von Mises stress were evaluated for intact and instrumentation models in all loading planes. Results All reconstructive conditions displayed decreased motion at L4–L5. The pedicle screw-plate system offered equal ROM to pedicle screw-rod system in unilateral or bilateral fixation modes respectively. Pedicle screw stresses for plate system were 2.2 times greater than those for rod system in left lateral bending under unilateral fixation. Stresses for plate were 3.1 times greater than those for rod in right axial rotation under bilateral fixation. Stresses on intervertebral graft for plate system were similar to rod system in unilateral and bilateral fixation modes respectively. Increased ROM and posterior instrumentation stresses were observed in all loading modes with unilateral fixation compared with bilateral fixation in both systems. Conclusions Transforaminal lumbar interbody fusion augmentation with pedicle screw-plate system fixation increases fusion construct stability equally to the pedicle screw-rod system. Increased posterior

  16. Support system design of the sub-mirror cell of the LAMOST Schmidt plate

    NASA Astrophysics Data System (ADS)

    Yang, Dehua; Jiang, Fanghua

    2006-06-01

    The reflecting Schmidt plate of the Large sky Area Multi-Object Spectroscopic Telescope (LAMOST) is composed of 24 hexagonal segments, each of which is 1100 mm from corner to corner and 25 mm in thickness. Both segmented mirror active optics and deformable mirror active optics are involved in the Schmidt plate so as to compensate for optical aberration and structural deformation. A prototype of the segment support system with dummy aluminum mirror had been setup and tested during 2003 to 2004, afterwards, based on the evaluation of test, the whole support system was updated to a backlash-free and light-weighted design. For the segmented mirror active optics, the segment mirror support system is to fulfill motions of tip, tilt and piston with three linear positioning actuators. Instead of self-alignment bearing adopted in the early prototype, a centering diaphragm is employed to realize a backlash-free pintle. And a lever with reduction of 10:1 is introduced to each of the three positioning actuator mechanisms, respectively, to obtain greater load capacity and further finer output displacement, as hence releases requirement and cost of the actuators. For better performance, high strength steel blades are used in tension state for pivots of the levers preloaded with longitudinal springs. To gap the mirror segments with respect to each other for making proper space for edge sensors, three adjustable fixtures are implemented for each segment mirror module to do translation and pistion on three conrresponding nodes on the top layer of the gross mirror cell truss before being anchored once and forever. In addition, safety measurements as well as anti-rotation mechanism have been taken into consideration throughout the design and development process. This paper describes the mechanical design and related analysis of the segment mirror support system in detail.

  17. The role of 3D plating system in mandibular fractures: A prospective study

    PubMed Central

    Prasad, Rajendra; Thangavelu, Kavin; John, Reena

    2013-01-01

    Aim: The aim of our study was to evaluate the advantages and disadvantages of 3D plating system in the treatment of mandibular fractures. Patients and Methods: 20 mandibular fractures in 18 patients at various anatomic locations and were treated by open reduction and internal fixation using 3D plates. All patients were followed at regular intervals of 4th, 8th and 12th weeks respectively. Patients were assessed post-operatively for lingual splay and occlusal stability. The incidence of neurosensory deficit, infection, masticatory difficulty, non-union, malunion was also assessed. Results: A significant reduction in lingual splay (72.2%) and occlusal stability (72.2%) was seen. The overall complication rate was (16.6%) which included two patients who developed post-operative paresthesia of lip, three patients had infection and two cases of masticatory difficulty which later subsided by higher antibiotics and 4 weeks of MMF. No evidence of non-union, malunion was noted. Conclusion: A single 3D 2 mm miniplate with 2 mm × 8 mm screws is a reliable and an effective treatment modality for mandibular fracture. PMID:23946559

  18. Preliminary Heat Flow Measurements from Plate Boundary Observatory Boreholes along the San Andreas Fault System

    NASA Astrophysics Data System (ADS)

    McDonald, K. J.; Harris, R. N.; Williams, C.; Grubb, F. V.; Fulton, P. M.; Chapman, D. S.

    2009-12-01

    Knowledge of the subsurface thermal regime is critical for understanding lithospheric rheology, fault mechanics and geodynamic processes. We report new heat flow values from boreholes drilled during the installation of borehole strain meters as part of the Plate Boundary Observatory (PBO) help constrain the role of temperature in determining the spatial and temporal pattern of deformation within along strike-slip faults in California. The new boreholes sites along this plate boundary system are clustered in the San Francisco Bay Area (n=5), San Juan Batista (n=5), Parkfield (n=7), and Anza (n=5). The boreholes vary in depth from 97 to 245 m. Temperature profiles were measured in each borehole and more than 899 thermal conductivity measurements were determined from drill cuttings and core samples. Heat production measurements are currently in progress. Temperature gradients have been corrected for the perturbing effects of terrain and combined with thermal conductivity to form thermal resistance plots and calculate heat flow. In general these plots indicate constant heat flow in the lower parts of the holes consistent with conductive heat transfer. Overall heat flow values are consistent with elevated heat flow that characterizes much of the California Coast Ranges. This study will help constrain the role of temperature in determining the spatial and temporal pattern of deformation within and along strike-slip faults in California.

  19. Patterns of seismogenesis for giant plate-boundary earthquakes in island-arc-type subduction systems

    NASA Astrophysics Data System (ADS)

    Kirby, S. H.

    2006-12-01

    The global record of giant earthquake occurrence in subduction zones during the instrumental and historical eras is woefully short; only about 16 events with magnitudes above 8.4 are reasonably well documented since 1700. We find no examples of giant (M > 8.4) interplate thrust events and/or wide-ranging tsunamis sourced in the classic island arcs with fast backarc spreading (Bonin, Marianas, Tonga-Kermadec, Vanuatu, and South Scotia). The Sumatra-Andaman Earthquake of 2004 (SAE) ruptured a sector of the INDIA-BURMA subduction boundary and evidently had no known historical antecedents, suggesting that the return time may be many centuries to millennia and consistent with low convergence rates. Moreover, the persistence of rupture to the north in the weakly volcanic Nicobar/Andaman sector gives one pause to reflect on the assumption that island arcs, especially those with active back-arc spreading such as the Marianas, do not produce great interplate- thrust earthquakes. The Andaman/Nicobar subduction segment is an unusual island arc. Only two arc volcanoes occur between the convergent plate boundary west of the Andamans and the backarc ridge/transform system to the east. Backarc spreading in the Andaman/ Nicobar segment is unusual because the NNW spreading directions are nearly parallel to the trench/deformation-front as do the INDIA-BURMA plate motions across it. This geometry suggests that arc-normal extension, trench migration and associated slab normal motions may not mechanically decouple this subduction system. The Nicobar sector of the rupture for the 2004 event is roughly 200 km wide judging from the aftershock distribution; a distribution that persists to the east under the Nicobar Islands, suggesting that the plate-boundary dip is very shallow in that latitude range. If this is correct, then the down-dip limitation on seismogenic slip set by serpentinized forearc mantle (Hyndman et al., 2003) may not control rupture width as it apparently does for many

  20. Wave-plate structures, power selective optical filter devices, and optical systems using same

    DOEpatents

    Koplow, Jeffrey P.

    2012-07-03

    In an embodiment, an optical filter device includes an input polarizer for selectively transmitting an input signal. The device includes a wave-plate structure positioned to receive the input signal, which includes first and second substantially zero-order, zero-wave plates arranged in series with and oriented at an angle relative to each other. The first and second zero-wave plates are configured to alter a polarization state of the input signal passing in a manner that depends on the power of the input signal. Each zero-wave plate includes an entry and exit wave plate each having a fast axis, with the fast axes oriented substantially perpendicular to each other. Each entry wave plate is oriented relative to a transmission axis of the input polarizer at a respective angle. An output polarizer is positioned to receive a signal output from the wave-plate structure and selectively transmits the signal based on the polarization state.

  1. High frequency analysis of a plate carrying a concentrated nonlinear spring-mass system

    NASA Astrophysics Data System (ADS)

    Culver, Dean; Dowell, Earl

    2016-09-01

    Examining the behavior of dynamical systems with many degrees of freedom undergoing random excitation at high frequency often requires substantial computation. These requirements are even more stringent for nonlinear systems. One approach for describing linear systems, Asymptotic Modal Analysis (AMA), has been extended to nonlinear systems in this paper. A prototypical system, namely a thin plate carrying a concentrated hardening cubic spring-mass, is explored. The study focuses on the response of three principal variables to random, frequency-bounded excitation: the displacement of the mounting location of the discrete spring-mass, the relative displacement of the discrete mass to this mounting location, and the absolute displacement of the discrete mass. The results indicate that extending AMA to nonlinear systems for input frequency bands containing a large number of modes is feasible. Several advantageous properties of nonlinear AMA are found, and an additional reduced frequency-domain modal method, Dominance-Reduced Classical Modal Analysis (DRCMA), is proposed that is intermediate in accuracy and the cost of computation between AMA and Classical Modal Analysis (CMA).

  2. Mantle flow geometry from ridge to trench beneath the Gorda-Juan de Fuca plate system

    NASA Astrophysics Data System (ADS)

    Martin-Short, Robert; Allen, Richard M.; Bastow, Ian D.; Totten, Eoghan; Richards, Mark A.

    2015-12-01

    Tectonic plates are underlain by a low-viscosity mantle layer, the asthenosphere. Asthenospheric flow may be induced by the overriding plate or by deeper mantle convection. Shear strain due to this flow can be inferred using the directional dependence of seismic wave speeds--seismic anisotropy. However, isolation of asthenospheric signals is challenging; most seismometers are located on continents, whose complex structure influences the seismic waves en route to the surface. The Cascadia Initiative, an offshore seismometer deployment in the US Pacific Northwest, offers the opportunity to analyse seismic data recorded on simpler oceanic lithosphere. Here we use measurements of seismic anisotropy across the Juan de Fuca and Gorda plates to reconstruct patterns of asthenospheric mantle shear flow from the Juan de Fuca mid-ocean ridge to the Cascadia subduction zone trench. We find that the direction of fastest seismic wave motion rotates with increasing distance from the mid-ocean ridge to become aligned with the direction of motion of the Juan de Fuca Plate, implying that this plate influences mantle flow. In contrast, asthenospheric mantle flow beneath the Gorda Plate does not align with Gorda Plate motion and instead aligns with the neighbouring Pacific Plate motion. These results show that asthenospheric flow beneath the small, slow-moving Gorda Plate is controlled largely by advection due to the much larger, faster-moving Pacific Plate.

  3. Constraints on Pacific plate kinematics and dynamics with global positioning system measurements

    NASA Technical Reports Server (NTRS)

    Dixon, T. H.; Golombek, M. P.; Thornton, C. L.

    1985-01-01

    A measurement program designed to investigate kinematic and dynamic aspects of plate tectonics in the Pacific region by means of satellite observations is proposed. Accuracy studies are summarized showing that for short baselines (less than 100 km), the measuring accuracy of global positioning system (GPS) receivers can be in the centimeter range. For longer baselines, uncertainty in the orbital ephemerides of the GPS satellites could be a major source of error. Simultaneous observations at widely (about 300 km) separated fiducial stations over the Pacific region, should permit an accuracy in the centimeter range for baselines of up to several thousand kilometers. The optimum performance level is based on the assumption of that fiducial baselines are known a priori to the centimeter range. An example fiducial network for a GPS study of the South Pacific region is described.

  4. Composite plate low energy impact localization system based on FBG sensing network and hybrid algorithm

    NASA Astrophysics Data System (ADS)

    Sai, Yaozhang; Jiang, Mingshun; Sui, Qingmei; Lu, Shizeng; Jia, Lei

    2015-08-01

    This paper proposed an impact localization system using fiber Bragg grating (FBG) network which is based on quasi-Newton algorithm and particle swarm optimization (PSO) algorithm. The FBG sensing network, formed by eight FBGs, was used to detect impact signals. And Shannon wavelet transform was employed to extract time differences. According to time differences and the coordinates of FBGs, nonlinear equations model of impact localization was established. Based on quasi-Newton algorithm and PSO algorithm, the nonlinear equations can be solved to obtain the coordinate of impact source. Testing experiments were carried out on a composite plate within 400 mm × 400 mm monitoring area. The experimental results showed that the maximum and average errors are 3.2 mm and 1.73 mm, respectively. The computational time is less than 2 s.

  5. Operation of a microchannel plate counting system in a mass spectrometer

    NASA Technical Reports Server (NTRS)

    Murphy, D. M.; Mauersberger, K.

    1985-01-01

    A multiplier detector system has been developed as part of a mass spectrometer in an ion counting mode. During its operation ions striking a microchannel plate release pulses of electrons which are accelerated to a phosphor layer. The resulting flash of light is carried by a fiber-optic bundle to a photodiode array. The detector simultaneously counts ions throughout a mass spectrum covering more than 30 amu. It extends the mass spectrometer's operation toward low count rates for trace gas analysis. Each mass peak can be independently measured at count rates between 0.1 and 1000 counts/s. Higher rates on a few peaks do not blind the entire detector. The detector's capabilities have been demonstrated by measuring Kr and Xe isotopes in air at natural abundances. The mass spectrometer, detector, and readout electronics are sufficiently compact to permit use in a balloon-borne experiment.

  6. Design study of multi-imaging plate system for BNCT irradiation field at Kyoto university reactor.

    PubMed

    Tanaka, Kenichi; Sakurai, Yoshinori; Kajimoto, Tsuyoshi; Tanaka, Hiroki; Takata, Takushi; Endo, Satoru

    2016-09-01

    The converter configuration for a multi-imaging plate system was investigated for the application of quality assurance in the irradiation field profile for boron neutron capture therapy. This was performed by the simulation calculation using the PHITS code in the fields at the Heavy Water Neutron Irradiation Facility of Kyoto University Reactor. The converter constituents investigated were carbon for gamma rays, and polyethylene with and without LiF at varied (6)Li concentration for thermal, epithermal, and fast neutrons. Consequently, potential combinations of the converters were found for two components, gamma rays and thermal neutrons, for the standard thermal neutron mode and three components of gamma rays, epithermal neutrons, and thermal or fast neutrons, for the standard mixed or epithermal neutron modes, respectively. PMID:27423022

  7. Progress towards a 256 channel multi-anode microchannel plate photomultiplier system with picosecond timing

    PubMed Central

    Lapington, J.S.; Ashton, T.J.R.; Ross, D.; Conneely, T.

    2012-01-01

    Despite the rapid advances in solid state technologies such as the silicon photomultiplier (SiPM), microchannel plate (MCP) photomultipliers still offer a proven and practical technological solution for high channel count pixellated photon-counting systems with very high time resolution. We describe progress towards a 256 channel optical photon-counting system using CERN-developed NINO and HTDC ASICs, and designed primarily for time resolved spectroscopy in life science applications. Having previously built and demonstrated a 18 mm diameter prototype tube with an 8×8 channel readout configuration and <43 ps rms single photon timing resolution, we are currently developing a 40 mm device with a 32×32 channel readout. Initially this will be populated with a 256 channel electronics system comprising four sets of modular 64 channel preamplifier/discriminator, and time-to-digital converter units, arranged in a compact three dimensional configuration. We describe the detector and electronics design and operation, and present performance measurements from the 256 channel development system. We discuss enhancements to the system including higher channel count and the use of application specific on-board signal processing capabilities. PMID:25843997

  8. Objective evaluation of interior trim effects on sound quality and noise reduction of a coupled plate cavity system

    NASA Astrophysics Data System (ADS)

    Egab, Laith; Wang, Xu

    2016-03-01

    In this study, the impedance mobility and psychoacoustic analysis methods are combined to develop a structural-acoustic model of a plate-cavity coupling system. The objective is to evaluate the effect of interior trim materials on sound loudness and sharpness of a plate-cavity coupling system. The impedance mobility method is applied to calculate the pressure frequency responses of the interior acoustic field for the plate-cavity coupling system. The sound pressure results calculated by the impedance mobility method are then directly used to calculate the psychoacoustic metrics using psychoacoustic analysis method. A good agreement was found between the experimental and analytical results. The results show that the interior trim has a large influence on the distribution of the sound loudness and sharpness inside the cavity in the middle and high frequency ranges.

  9. Extended Plate and Beam Wall System: Concept Investigation and Initial Evaluation

    SciTech Connect

    Wiehagen, J.; Kochkin, V.

    2015-08-01

    A new and innovative High-R wall design, referred to as the Extended Plate & Beam (EP&B), is under development. The EP&B system uniquely integrates foam sheathing insulation with wall framing such that wood structural panels are installed exterior of the foam sheathing, enabling the use of standard practices for installation of drainage plane, windows and doors, claddings, cavity insulation, and the standard exterior foam sheathing installation approach prone to damage of the foam during transportation of prefabricated wall panels. As part of the ongoing work, the EP&B wall system concept has undergone structural verification testing and has been positively vetted by a group of industry stakeholders. Having passed these initial milestone markers, the advanced wall system design has been analyzed to assess cost implications relative to other advanced wall systems, undergone design assessment to develop construction details, and has been evaluated to develop representative prescriptive requirements for the building code. This report summarizes the assessment steps conducted to-date and provides details of the concept development.

  10. Validation of a sensitive and automated 96-well solid-phase extraction liquid chromatography-tandem mass spectrometry method for the determination of desloratadine and 3-hydroxydesloratadine in human plasma.

    PubMed

    Yang, Liyu; Clement, Robert P; Kantesaria, Bhavna; Reyderman, Larisa; Beaudry, Francis; Grandmaison, Charles; Di Donato, Lorella; Masse, Robert; Rudewicz, Patrick J

    2003-07-25

    To support clinical development, a liquid chromatographic-tandem mass spectrometric (LC-MS-MS) method was developed and validated for the determination of desloratadine (descarboethoxyloratadine) and 3-OH desloratadine (3-hydroxydescarboethoxyloratadine) concentrations in human plasma. The method consisted of automated 96-well solid-phase extraction for sample preparation and liquid chromatography/turbo ionspray tandem mass spectrometry for analysis. [2H(4)]Desloratadine and [2H(4)]3-OH desloratadine were used as internal standards (I.S.). A quadratic regression (weighted 1/concentration(2)) gave the best fit for calibration curves over the concentration range of 25-10000 pg/ml for both desloratadine and 3-OH desloratadine. There was no interference from endogenous components in the blank plasma tested. The accuracy (%bias) at the lower limit of quantitation (LLOQ) was -12.8 and +3.4% for desloratadine and 3-OH desloratadine, respectively. The precision (%CV) for samples at the LLOQ was 15.1 and 10.9% for desloratadine and 3-OH desloratadine, respectively. For quality control samples at 75, 1000 and 7500 pg/ml, the between run %CV was

  11. Fluid-structure interaction study of the splitter plate in a TBCC exhaust system during mode transition phase

    NASA Astrophysics Data System (ADS)

    Guo, Shuai; Xu, Jinglei; Mo, Jianwei; Gu, Rui; Pang, Lina

    2015-07-01

    Splitter plate plays an important role in a turbine-based combined-cycle (TBCC) exhaust system during the mode transition phase when turbojet engine and ramjet engine operate simultaneously. Dissimilar pressure distribution on both sides of the plate has a potential origin in the aeroelastic coupling, which is an interesting topic while few research works have devoted to that aspect. To better understand the aeroelastic behavior of the plate and the corresponding dynamic flow features, an integrated fluid-structure interaction simulation is conducted under one particular operation condition during mode transition phase in the TBCC exhaust system. A finite-volume-based CFD solver FLUENT is adopted to solve the unsteady Reynolds average Navier-Stokes equations. ABAQUS, a finite-element-method-based CSD solver, is employed to compute the plate elastic deformation. A two-way interaction between the fluid and the structure is accomplished by the mesh-based parallel-code coupling interface (MpCCI) in a loosely-coupled manner. The accuracy of the coupling procedure is validated for the flutter of a flat plate in supersonic flow. Then, features of steady flow field of the TBCC exhaust system are discussed, followed by the investigation of the aeroelastic phenomenon of the splitter plate and the evolution process of the flow field pattern. Finally, performances variation of the exhaust system is obtained and discussed. The results show that the plate vibrates with decaying amplitude and reaches a dynamic stable state eventually. The thrust, lift and pitch moment of the TBCC exhaust system are increased by 0.68%, 2.82% and 5.86%, respectively, compared with the corresponding values in steady state which does not take into account the fluid-structure interaction effects. The analysis reveals the importance of considering the fluid-structure interaction effects in designing the splitter plate in the TBCC exhaust system and demonstrates the availability of the present coupled

  12. An improved plating process

    NASA Technical Reports Server (NTRS)

    Askew, John C.

    1994-01-01

    An alternative to the immersion process for the electrodeposition of chromium from aqueous solutions on the inside diameter (ID) of long tubes is described. The Vessel Plating Process eliminates the need for deep processing tanks, large volumes of solutions, and associated safety and environmental concerns. Vessel Plating allows the process to be monitored and controlled by computer thus increasing reliability, flexibility and quality. Elimination of the trivalent chromium accumulation normally associated with ID plating is intrinsic to the Vessel Plating Process. The construction and operation of a prototype Vessel Plating Facility with emphasis on materials of construction, engineered and operational safety and a unique system for rinse water recovery are described.

  13. Plate motion

    SciTech Connect

    Gordon, R.G. )

    1991-01-01

    The motion of tectonic plates on the earth is characterized in a critical review of U.S. research from the period 1987-1990. Topics addressed include the NUVEL-1 global model of current plate motions, diffuse plate boundaries and the oceanic lithosphere, the relation between plate motions and distributed deformations, accelerations and the steadiness of plate motions, the distribution of current Pacific-North America motion across western North America and its margin, plate reconstructions and their uncertainties, hotspots, and plate dynamics. A comprehensive bibliography is provided. 126 refs.

  14. The olfactory sensory system develops from coordinated movements within the neural plate

    PubMed Central

    Torres-Paz, Jorge

    2014-01-01

    Background The peripheral olfactory sensory system arises from morphologically identifiable structures called placodes. Placodes are relatively late developing structures, evident only well after the initiation of somitogenesis. Placodes are generally described as being induced from the ectoderm suggesting that their development is separate from the coordinated cell movements generating the central nervous system. Results With the advent of modern techniques it is possible to follow the development of the neurectoderm giving rise to the anterior neural tube, including the olfactory placodes. The cell movements giving rise to the optic cup are coordinated with those generating the olfactory placodes and adjacent telencephalon. The formation of the basal lamina separating the placode from the neural tube is coincident with the anterior migration of cranial neural crest. Conclusions Olfactory placodes are transient morphological structures arising from a continuous sheet of neurectoderm that gives rise to the peripheral and central nervous system. This field of cells is specified at the end of gastrulation and not secondarily induced from ectoderm. The separation of olfactory placodes and telencephalon occurs through complex cell movements within the developing neural plate similar to that observed for the developing optic cup. PMID:25255735

  15. Image-based fluidic sorting system for automated Zebrafish egg sorting into multiwell plates.

    PubMed

    Graf, Siegfried F; Hötzel, Sebastian; Liebel, Urban; Stemmer, Andreas; Knapp, Helmut F

    2011-04-01

    The global demand for the reduction of animal testing has led to the emergence of Zebrafish eggs/larvae as model organisms to replace current adult animal testing in, for example, toxicity testing. Because of the egg size (diameter 1.6mm) and the relatively easy maintenance of Zebrafish farms the eggs also offer high-throughput screening (HTS). However, the current bottleneck for HTS is the cost-efficient placing of individual organisms into single wells of a multiwell plate (MWP). The system presented here is capable of storing, sorting, and placing individual organisms in a highly reproducible manner. In about 11 min a complete 96-MWP is filled, which corresponds to about 8 sec per egg. The survival rate of fertilized transgenic and wild-type eggs was comparable to the one of the control (control 6.7%, system 7.6%). Furthermore, it was also possible to place dechorionated eggs into individual wells. The results demonstrate that the cost efficient system works gentle and reliable enough to disburden scientists from the exhausting and monotonous job of placing single eggs into single wells, such that they can concentrate on the scientific aspects of their experiments and create results with a higher statistical relevance. PMID:21609691

  16. Enzyme activity deviates due to spatial and temporal temperature profiles in commercial microtiter plate readers.

    PubMed

    Grosch, Jan-Hendrik; Sieben, Michaela; Lattermann, Clemens; Kauffmann, Kira; Büchs, Jochen; Spieß, Antje C

    2016-03-01

    Microtiter plates (MTP) and automatized techniques are increasingly applied in the field of biotechnology. However, the susceptibility of MTPs to edge effects such as thermal gradients can lead to high variation of measured enzyme activities. In an effort to enhance experimental reliability, to quantify, and to minimize instrument-caused deviations in enzyme kinetics between two MTP-readers, we comprehensively quantified temperature distribution in 96-well MTPs. We demonstrated the robust application of the absorbance dye cresol red as easily applicable temperature indicator in cuvettes and MTPs and determined its accuracy to ±0.16°C. We then quantified temperature distributions in 96-well MTPs revealing temperature deviations over single MTP of up to 2.2°C and different patterns in two commercial devices (BioTek Synergy 4 and Synergy Mx). The obtained liquid temperature was shown to be substantially controlled by evaporation. The temperature-induced enzyme activity variation within MTPs amounted to about 20 %. Activity deviations between MTPs and to those in cuvettes were determined to 40 % due to deviations from the set temperature in MTPs. In conclusion, we propose a better control of experimental conditions in MTPs or alternative experimental systems for reliable determination of kinetic parameters for bioprocess development. PMID:26709721

  17. Towards a laboratory-based calibration of the Swiss plate geophone bedload monitoring system

    NASA Astrophysics Data System (ADS)

    Rodrigo Wyss, Carlos; Rickenmann, Dieter; Fritschi, Bruno; Turowski, Jens Martin; Weitbrecht, Volker; Boes, Robert Michael

    2015-04-01

    The Swiss plate geophone is an indirect bedload monitoring device that is used to continuously monitor bedload transport. The Swiss plate geophone consists of a geophone sensor that measures the elastic deformation of a steel plate induced by the collision of a bedload particle. Differences between bedload particle shape and sizes as well as in-situ hydraulic conditions control the particle transport mode, and these elements have so far required a field calibration of the Swiss plate geophone. In this study, we performed flume experiments with varying bedload transport parameters like particle size and mean flow velocity with natural bedload particles from the Erlenbach stream, Central Switzerland. The impulses, i.e. the number of times the signal recorded by the Swiss plate geophone exceeds a predefined threshold, and wave packets representing a single impact are used to compute laboratory-based calibration curves. These calibration curves are then used as a framework to estimate bedload mass from the impulses and packets registered in the field. Estimated and measured bedload mass are compared for more than 50 bedload samples taken by the automatic basket samplers at the Erlenbach. The results emphasize the sensitivity of the Swiss plate geophone to different hydraulic parameters, in particular mean flow velocity and bed roughness. We conclude that to calibrate the Swiss plate geophone in the laboratory, the hydraulic conditions like bed roughness and Froude numbers have to be replicated. Keywords: Swiss plate geophone, calibration, flume experiments, bedload transport, indirect measurement.

  18. Lameness scoring system for dairy cows using force plates and artificial intelligence.

    PubMed

    Ghotoorlar, S Mokaram; Ghamsari, S Mehdi; Nowrouzian, I; Ghotoorlar, S Mokaram; Ghidary, S Shiry

    2012-02-01

    Lameness scoring is a routine procedure in dairy industry to screen the herds for new cases of lameness. Subjective lameness scoring, which is the most popular lameness detection and screening method in dairy herds, has several limitations. They include low intra-observer and inter-observer agreement and the discrete nature of the scores which limits its usage in monitoring the lameness. The aim of this study is to develop an automated lameness scoring system comparable with conventional subjective lameness scoring by means of artificial neural networks. The system is composed of four balanced force plates installed in a hoof-trimming box. A group of 105 dairy cows was used for the study. Twenty-three features extracted from ground reaction force (GRF) data were used in a computer training process which was performed on 60 per cent of the data. The remaining 40 per cent of the data were used to test the trained system. Repeatability of the lameness scoring system was determined by GRF samples from 25 cows, captured at two different times from the same animals. The mean sd was 0.31 and the mean coefficient of variation was 14.55 per cent, which represents a high repeatability in comparison with subjective vision-based scoring methods. Although the highest sensitivity and specificity values were seen in locomotion score groups 1 and 4, the automatic lameness system was both sensitive and specific in all groups. The sensitivity and specificity were higher than 72 per cent in locomotion score groups 1 to 4, and it was 100 per cent specific and 50 per cent sensitive for group 5. PMID:22141114

  19. Cavity-Enhanced Immunoassay Measurements in Microtiter Plates Using BBCEAS.

    PubMed

    Bajuszova, Zuzana; Ali, Zulfiqur; Scott, Simon; Seetohul, L Nitin; Islam, Meez

    2016-05-17

    We report on the first detailed use of broadband cavity enhanced absorption spectroscopy (BBCEAS) as a detection system for immunoassay. A vertical R ≥ 0.99 optical cavity was integrated with a motorized XY stage, which functioned as a receptacle for 96-well microtiter plates. The custom-built cavity enhanced microplate reader was used to make measurements on a commercially available osteocalcin sandwich ELISA kit. A 30-fold increase in path length was obtained with a minimum detectable change in the absorption coefficient, αmin(t), of 5.3 × 10(-5) cm(-1) Hz(-1/2). This corresponded to a 39-fold increase in the sensitivity of measurement when directly compared to measurements in a conventional microplate reader. Separate measurements of a standard STREP-HRP colorimetric reaction in microtiter plates of differing optical quality produced an increase in sensitivity of up to 115-fold compared to a conventional microplate reader. The sensitivity of the developed setup compared favorably with previous liquid-phase cavity enhanced studies and approaches the sensitivity of typical fluorometric ELISAs. It could benefit any biochemical test which uses single pass absorption as a detection method, through either the label free detection of biologically important molecules at lower concentrations or the reduction in the amount of expensive biochemicals needed for a particular test, leading to cheaper tests. PMID:27089516

  20. Finite difference based vibration simulation analysis of a segmented distributed piezoelectric structronic plate system

    NASA Astrophysics Data System (ADS)

    Ren, B. Y.; Wang, L.; Tzou, H. S.; Yue, H. H.

    2010-08-01

    Electrical modeling of piezoelectric structronic systems by analog circuits has the disadvantages of huge circuit structure and low precision. However, studies of electrical simulation of segmented distributed piezoelectric structronic plate systems (PSPSs) by using output voltage signals of high-speed digital circuits to evaluate the real-time dynamic displacements are scarce in the literature. Therefore, an equivalent dynamic model based on the finite difference method (FDM) is presented to simulate the actual physical model of the segmented distributed PSPS with simply supported boundary conditions. By means of the FDM, the four-ordered dynamic partial differential equations (PDEs) of the main structure/segmented distributed sensor signals/control moments of the segmented distributed actuator of the PSPS are transformed to finite difference equations. A dynamics matrix model based on the Newmark-β integration method is established. The output voltage signal characteristics of the lower modes (m <= 3, n <= 3) with different finite difference mesh dimensions and different integration time steps are analyzed by digital signal processing (DSP) circuit simulation software. The control effects of segmented distributed actuators with different effective areas are consistent with the results of the analytical model in relevant references. Therefore, the method of digital simulation for vibration analysis of segmented distributed PSPSs presented in this paper can provide a reference for further research into the electrical simulation of PSPSs.

  1. Chlorine isotope geochemistry of Icelandic thermal fluids: Implications for geothermal system behavior at divergent plate boundaries

    NASA Astrophysics Data System (ADS)

    Stefánsson, Andri; Barnes, Jaime D.

    2016-09-01

    The chlorine isotope composition of thermal fluids from Iceland were measured in order to evaluate the source of chlorine and possible chlorine isotope fractionation in geothermal systems at divergent plate boundaries. The geothermal systems studied have a wide range of reservoir temperatures from 40 to 437 °C and in-situ pH of 6.15 to 7.15. Chlorine concentrations range from 5.2 to 171 ppm and δ37 Cl values are -0.3 to + 2.1 ‰ (n = 38). The δ37 Cl values of the thermal fluids are interpreted to reflect the source of the chlorine in the fluids. Geothermal processes such as secondary mineral formation, aqueous and vapor speciation and boiling were found to have minimal effects on the δ37 Cl values. However, further work is needed on incorporation of Cl into secondary minerals and its effect on Cl isotope fractionation. Results of isotope geochemical modeling demonstrate that the range of δ37 Cl values documented in the natural thermal fluids can be explained by leaching of the basaltic rocks by meteoric source water under geothermal conditions. Magmatic gas partitioning may also contribute to the source of Cl in some cases. The range of δ37 Cl values of the fluids result mainly from the large range of δ37 Cl values observed for Icelandic basalts, which range from -0.6 to + 1.2 ‰.

  2. Continuous distributed phase-plate advances for high-energy laser systems

    NASA Astrophysics Data System (ADS)

    Marozas, J. A.; Collins, T. J. B.; Zuegel, J. D.; McKenty, P. W.; Cao, D.; Fochs, S.; Radha, P. B.

    2016-05-01

    The distributed phase plate (DPP) design code Zhizhoo’ has been used to design full- aperture, continuous near-field transmission optics for a wide variety of high-fidelity focal-spot shapes for high-energy laser systems: OMEGA EP, Dynamic Compression Sector (DCS), and the National Ignition Facility (NIF). The envelope shape, or profile, of the focal spot affects the hydrodynamics of directly driven targets in these laser systems. Controlling the envelope shape to a high degree of fidelity impacts the quality of the ablatively driven implosions. The code Zhizhoo’ not only produces DPP's with great control of the envelope shape, but also spectral and gradient control as well as robustness from near-field phase aberrations. The focal-spot shapes can take on almost any profile from symmetric to irregular patterns and with high fidelity relative to the objective function over many decades of intensity. The control over the near-field phase spectrum and phase gradients offer greater manufacturability of the full- aperture continuous surface-relief pattern. The flexibility and speed of the DPP design code Zhizhoo’ will be demonstrated by showing the wide variety of successful designs that have been made and those that are in progress.

  3. Numerical modeling of optical properties of a system of two zone plates for focusing hard synchrotron radiation

    SciTech Connect

    Kohn, V. G. Snigireva, I. I.; Snigirev, A. A.

    2006-12-15

    Results of numerical experiments on focusing of a monochromatic spherical wave by a system of two linear zone plates are reported. Calculations were performed for a photon energy of 12.3985 keV and zone plates with a radius of the first zone of 5 {mu}m, a number of zones of 628, and an aperture of 250 {mu}m. To calculate the Kirchhoff integrals, the double Fourier transform method was used and the fast Fourier transform procedure on a grid with a number of points 65 536 = 2{sup 16} was applied. On the basis of the calculation results, a conclusion was drawn that two zone plates operate as one with a doubled phase shift in zones with a material if the longitudinal distance between them is smaller than 1/3 of the focus depth and the transverse displacement is smaller than 1/3 of the outermost zone width (the focus size). If the distance (displacement) exceeds the focus depth (size), the two zone plates operate independently, similar to refracting lenses with a set of different focusing orders, including the zero order. The nature of the moire pattern at a transverse displacement of the zone plates is discussed.

  4. An Expert System to Analyze Homogeneity in Fuel Element Plates for Research Reactors

    SciTech Connect

    Tolosa, S.C.; Marajofsky, A.

    2004-10-06

    In the manufacturing control of Fuel Element Plates for Research Reactors, one of the problems to be addressed is how to determine the U-density homogeneity in a fuel plate and how to obtain qualitative and quantitative information in order to establish acceptance or rejection criteria for such, as well as carrying out the quality follow-up. This paper is aimed at developing computing software which implements an Unsupervised Competitive Learning Neural Network for the acknowledgment of regions belonging to a digitalized gray scale image. This program is applied to x-ray images. These images are generated when the x-ray beams go through a fuel plate of approximately 60 cm x 8 cm x 0.1 cm thick. A Nuclear Fuel Element for Research Reactors usually consists of 18 to 22 of these plates, positioned in parallel, in an arrangement of 8 x 7 cm. Carrying out the inspection of the digitalized x-ray image, the neural network detects regions with different luminous densities corresponding to U-densities in the fuel plate. This is used in quality control to detect failures and verify acceptance criteria depending on the homogeneity of the plate. This modality of inspection is important as it allows the performance of non-destructive measurements and the automatic generation of the map of U-relative densities of the fuel plate.

  5. Automated DNA Sequencing System

    SciTech Connect

    Armstrong, G.A.; Ekkebus, C.P.; Hauser, L.J.; Kress, R.L.; Mural, R.J.

    1999-04-25

    Oak Ridge National Laboratory (ORNL) is developing a core DNA sequencing facility to support biological research endeavors at ORNL and to conduct basic sequencing automation research. This facility is novel because its development is based on existing standard biology laboratory equipment; thus, the development process is of interest to the many small laboratories trying to use automation to control costs and increase throughput. Before automation, biology Laboratory personnel purified DNA, completed cycle sequencing, and prepared 96-well sample plates with commercially available hardware designed specifically for each step in the process. Following purification and thermal cycling, an automated sequencing machine was used for the sequencing. A technician handled all movement of the 96-well sample plates between machines. To automate the process, ORNL is adding a CRS Robotics A- 465 arm, ABI 377 sequencing machine, automated centrifuge, automated refrigerator, and possibly an automated SpeedVac. The entire system will be integrated with one central controller that will direct each machine and the robot. The goal of this system is to completely automate the sequencing procedure from bacterial cell samples through ready-to-be-sequenced DNA and ultimately to completed sequence. The system will be flexible and will accommodate different chemistries than existing automated sequencing lines. The system will be expanded in the future to include colony picking and/or actual sequencing. This discrete event, DNA sequencing system will demonstrate that smaller sequencing labs can achieve cost-effective the laboratory grow.

  6. Twenty-four-well plate miniature bioreactor high-throughput system: assessment for microbial cultivations.

    PubMed

    Isett, Kevin; George, Hugh; Herber, Wayne; Amanullah, Ashraf

    2007-12-01

    High-throughput (HT) miniature bioreactor (MBR) systems are becoming increasingly important to rapidly perform clonal selection, strain improvement screening, and culture media and process optimization. This study documents the initial assessment of a 24-well plate MBR system, Micro (micro)-24, for Saccharomyces cerevisiae, Escherichia coli, and Pichia pastoris cultivations. MBR batch cultivations for S. cerevisiae demonstrated comparable growth to a 20-L stirred tank bioreactor fermentation by off-line metabolite and biomass analyses. High inter-well reproducibility was observed for process parameters such as on-line temperature, pH and dissolved oxygen. E. coli and P. pastoris strains were also tested in this MBR system under conditions of rapidly increasing oxygen uptake rates (OUR) and at high cell densities, thus requiring the utilization of gas blending for dissolved oxygen and pH control. The E. coli batch fermentations challenged the dissolved oxygen and pH control loop as demonstrated by process excursions below the control set-point during the exponential growth phase on dextrose. For P. pastoris fermentations, the micro-24 was capable of controlling dissolved oxygen, pH, and temperature under batch and fed-batch conditions with subsequent substrate shot feeds and supported biomass levels of 278 g/L wet cell weight (wcw). The average oxygen mass transfer coefficient per non-sparged well were measured at 32.6 +/- 2.4, 46.5 +/- 4.6, 51.6 +/- 3.7, and 56.1 +/- 1.6 h(-1) at the operating conditions of 500, 600, 700, and 800 rpm shaking speed, respectively. The mixing times measured for the agitation settings 500 and 800 rpm were below 5 and 1 s, respectively. PMID:17486656

  7. Injury to the anterior tibial system during percutaneous plating of a proximal tibial fracture.

    PubMed

    Gary, Joshua L; Sciadini, Marcus F

    2012-07-01

    Minimally invasive osteosynthesis of proximal tibial fractures has grown in popularity in recent years. This article describes a patient with a Schatzker type VI proximal tibial fracture (AO/OTA type 41.C3) and previous compartment syndrome treated with definitive fixation 8 weeks after initial injury with a precontoured proximal tibial plate and a distal targeting device. Brisk bleeding occurred during percutaneous insertion of a cortical screw at the midshaft of the tibia. Surgical exploration revealed sidewall tearing of the anterior tibial artery and vein, which were clipped at the screw insertion site. After the bleeding was controlled, the patient had a strong palpable posterior tibial pulse with no palpable dorsalis pedis pulse, and the foot remained well perfused. Function of the deep peroneal nerve was normal postoperatively. Previous concerns regarding the percutaneous treatment of proximal tibial fractures have focused on the risks of damage to the superficial peroneal nerve from distal screws. Based on cadaveric studies, percutaneously and laterally based screw placement in the distal tibial metaphysis threatens injury to the anterior tibial system. However, with alterations to the normal anatomy caused by severe trauma, previously described safe zones may be changed and neurovascular structures may be exposed to risk in locations that were previously thought safe. PMID:22784915

  8. CMS Resistive Plate Chamber overview, from the present system to the upgrade phase I

    NASA Astrophysics Data System (ADS)

    Paolucci, P.; Hadjiiska, R.; Litov, L.; Pavlov, B.; Petkov, P.; Dimitrov, A.; Beernaert, K.; Cimmino, A.; Costantini, S.; Guillaume, G.; Lellouch, J.; Marinov, A.; Ocampo, A.; Strobbe, N.; Thyssen, F.; Tytgat, M.; Verwilligen, P.; Yazgan, E.; Zaganidis, N.; Aleksandrov, A.; Genchev, V.; Iaydjiev, P.; Rodozov, M.; Shopova, M.; Sultanov, G.; Ban, Y.; Cai, J.; Xue, Z.; Ge, Y.; Li, Q.; Qian, S.; Avila, C.; Chaparro, L. F.; Gomez, J. P.; Gomez Moreno, B.; Osorio Oliveros, A. F.; Sanabria, J. C.; Assran, Y.; Sharma, A.; Abbrescia, M.; Colaleo, A.; Pugliese, G.; Loddo, F.; Calabria, C.; Maggi, M.; Benussi, L.; Bianco, S.; Colafranceschi, S.; Piccolo, D.; Carrillo, C.; Iorio, O.; Buontempo, S.; Vitulo, P.; Berzano, U.; Gabusi, M.; Kang, M.; Lee, K. S.; Park, S. K.; Shin, S.; Kim, M. S.; Seo, H. K.; Goh, J.; Choi, Y.-I.

    2013-04-01

    Resistive Plate Chambers have been chosen as dedicated trigger muon detector for the Compact Muon Solenoid experiment [1] at the Large Hadron Collider [2] at CERN. The system consists of about 3000 m2 of double gap RPC chambers placed in both the barrel and endcap muon regions. About 5.6 fb-1 (2010-2011) of proton-proton collision data have been used to study the performance of the RPC detector and trigger. A full high voltage scan of all the RPC chambers has been done at beginning of 2011 data taking to evaluate the working point chamber by chamber and to eventually spot aging effects. The excellent behaviour of the RPC detector can be summarized with an average detector efficiency of about 97%, an average cluster size of 1.8 and an intrinsic noise rate of 0.1 Hz/cm2. This is a clear fulfilment of all the requirements decided 18 years ago in the CMS TDR document [3].

  9. International Space Station Internal Thermal Control System Cold Plate/Fluid-Stability Test: Two Year Update

    NASA Technical Reports Server (NTRS)

    Wieland, Paul; Holt, Mike; Roman, Monsi; Cole, Harold; Daugherty, Steve

    2003-01-01

    Operation of the Internal Thermal Control System (ITCS) Cold Plate/Fluid-Stability Test Facility commenced on September 5, 2000. The facility was intended to provide advance indication of potential problems on board the International Space Station (ISS) and was designed: 1) To be materially similar to the flight ITCS. 2) To allow for monitoring during operation. 3) To run continuously for three years. During the first two years of operation the conditions of the coolant and components were remarkably stable. During this same period of time, the conditions of the ISS ITCS significantly diverged from the desired state. Due to this divergence, the test facility has not been providing information useful for predicting the flight ITCS condition. Results of the first two years are compared with flight conditions over the same time period, showing the similarities and divergences. To address the divergences, the test facility was modified incrementally to more closely match the flight conditions, and to gain insight into the reasons for the divergence. Results of these incremental changes are discussed and provide insight into the development of the conditions on orbit.

  10. Analysis of active control with on-line system identification on sound transmission through an elastic plate

    NASA Astrophysics Data System (ADS)

    Koshigoe, Shozo; Teagle, Allen; Tsay, Ching-Hsu

    1995-05-01

    An adaptive control algorithm with on-line system identification capability has been developed. One of the great advantages of this scheme is that an additional system identification mechanism such as an additional uncorrelated random signal generator as the source of system identification [Eriksson and Allie, Acoust. Soc. Am. 85, 797 - 802 (1989)] is not required. A time varying plate-cavity system is used to demonstrate the control performance of this algorithm. The time varying plate-cavity system is used to demonstrate the control performance of this algorithm. The time varying system consists of a stainless steel plate which is simply supported on a rigid cavity where the cavity temperature can depend on time. For a given externally located harmonic sound excitation, the system identification and the control are simultaneously executed to minimize the transmitted sound in the cavity. The control performance of the algorithm is examined for two cases. Keeping the cavity temperature constant for the first case, the external disturbance frequency is swept with 2 Hz/second from below to above a resonance frequency of the plate-cavity system. The simulation shows an excellent frequency tracking capability with cavity internal sound suppression of 40 dB. For the second case, the cavity temperature is lowered to a half of its original value in 60 seconds while the external sound excitation is fixed with a frequency. Hence, the cavity resonant frequency decreased and passes the external sound excitation frequency. The algorithm shows 40 dB transmitted noise suppression without compromising the system identification tracking capability.

  11. Hypervelocity plate acceleration

    SciTech Connect

    Marsh, S.P.; Tan, T.H.

    1991-01-01

    Shock tubes have been used to accelerate 1.5-mm-thick stainless steel plates to high velocity while retaining their integrity. The fast shock tubes are 5.1-cm-diameter, 15.2-cm-long cylinders of PBX-9501 explosive containing a 1.1-cm-diameter cylindrical core of low-density polystyrene foam. The plates have been placed directly in contact with one face of the explosive system. Plane-wave detonation was initiated on the opposite face. A Mach disk was formed in the imploding styrofoam core, which provided the impulse required to accelerate the metal plate to high velocity. Parametric studies were made on this system to find the effect of varying plate metal, plate thickness, foam properties, and addition of a barrel. A maximum plate velocity of 9.0 km/s has been observed. 6 refs., 17 figs.

  12. Measuring Ca²⁺ changes in multiwell format using the Fluorometric Imaging Plate Reader (FLIPR(®)).

    PubMed

    Marshall, Ian C B; Owen, Davina E; McNulty, Shaun

    2013-01-01

    The Fluorometric Imaging Plate Reader (FLIPR) has made a significant contribution to drug discovery programs. The key advantage of FLIPR over conventional plate readers is the ability to measure fluorescence emission from multiple wells (96 wells or 384 wells) simultaneously and with high temporal resolution. Consequently, FLIPR has been used extensively to record dynamic intracellular processes such as changes in intracellular Ca(2+) ion concentration, membrane potential, and pH. Since FLIPR is used to measure a functional response in cells, it is rapidly able to distinguish full agonists, partial agonists, and antagonists at a target of interest, making the system a valuable screening tool for interrogation of compound libraries. Automated FLIPR systems for ultra high throughput have also become available that employ integrated plate stackers, washers and specialized stages to allow users to shuttle cell and compound plates from incubators or storage magazines onto the FLIPR system itself. In this chapter generic methods for assessing intracellular Ca(2+) on the FLIPR are described. PMID:23007581

  13. The European Plate Observing System (EPOS) Services for Solid Earth Science

    NASA Astrophysics Data System (ADS)

    Cocco, Massimo; Atakan, Kuvvet; Pedersen, Helle; Consortium, Epos

    2016-04-01

    The European Plate Observing System (EPOS) aims to create a pan-European infrastructure for solid Earth science to support a safe and sustainable society. The main vision of the European Plate Observing System (EPOS) is to address the three basic challenges in Earth Sciences: (i) unravelling the Earth's deformational processes which are part of the Earth system evolution in time, (ii) understanding the geo-hazards and their implications to society, and (iii) contributing to the safe and sustainable use of geo-resources. The mission of EPOS is to monitor and understand the dynamic and complex Earth system by relying on new e-science opportunities and integrating diverse and advanced Research Infrastructures in Europe for solid Earth Science. EPOS will enable innovative multidisciplinary research for a better understanding of the Earth's physical and chemical processes that control earthquakes, volcanic eruptions, ground instability and tsunami as well as the processes driving tectonics and Earth's surface dynamics. EPOS will improve our ability to better manage the use of the subsurface of the Earth. Through integration of data, models and facilities EPOS will allow the Earth Science community to make a step change in developing new concepts and tools for key answers to scientific and socio-economic questions concerning geo-hazards and geo-resources as well as Earth sciences applications to the environment and to human welfare. EPOS has now started its Implementation Phase (EPOS-IP). One of the main challenges during the implementation phase is the integration of multidisciplinary data into a single e-infrastructure. Multidisciplinary data are organized and governed by the Thematic Core Services (TCS) and are driven by various scientific communities encompassing a wide spectrum of Earth science disciplines. These include Data, Data-products, Services and Software (DDSS), from seismology, near fault observatories, geodetic observations, volcano observations

  14. A microELISA assay for detection of anti-HLA activity of mouse monoclonal antibodies using an Astroscan 2100 automated plate reader.

    PubMed

    Sadler, A M; Krausa, P; Marsh, S G; Heyes, J M; Bodmer, J G

    1992-04-27

    A microenzyme-linked immunosorbent assay (microELISA) method has been developed using an Astroscan 2100 system automated plate reader which was initially designed for tissue typing by a two colour fluorescent microcytotoxicity assay. A 96-well plate ELISA used for screening mouse monoclonal antibodies raised against surface HLA antigens has been modified for use with the Astroscan plate reader and 72-well typing trays. The existing substrate 4-methylumbelliferyl-beta-D-galactoside (4MUG) has been replaced with fluorescein-di-beta-D-galactopyranoside (FDG), to provide a wavelength (530 nm) detectable by the Astroscan or other automated plate readers designed for reading microcytotoxicity assay plates. The assay volumes have also been reduced tenfold for use with Terasaki microtest plates. The assay now has the major advantage of requiring only 5 microliters of test supernatant allowing hybridomas to be screened earlier during a fusion and on a wider cell panel. The use of the large panel which includes B lymphoblastoid cell lines (B-LCL) and mouse L cell transfectants expressing HLA genes, reduces the length of time the hybridomas need to be kept in tissue culture before selection. Other advantages include the reduction in the number of target cells required, smaller volumes of reagents throughout the assay and the ability to screen cytotoxic as well as non-cytotoxic monoclonal antibodies. The sensitivity of this microELISA proved to be comparable with the original assay and so provides an efficient screening method for monoclonal antibodies. PMID:1583310

  15. Development of a System to Measure Austenite Grain Size of Plate Steel Using Laser-Based Ultrasonics

    SciTech Connect

    Lim, C. S.; Hong, S. T.; Yi, J. K.; Choi, S. G.; Oh, K. J.; Nagata, Y.; Yamada, H.; Hamada, N.

    2007-03-21

    A measurement system for austenite grain size of plate steel using laser-based ultrasonics has been developed. At first, the relationship between the ultrasonic attenuation coefficients using longitudinal waves and austenite grain size of samples was investigated in the laboratory experiments. According to the experimental results, the ultrasonic attenuation coefficients showed a good correlation with actual austenite grain sizes. For the next step, the system was installed in a hot rolling pilot plant of plate steel, and it was verified that the austenite grain size could be measured even in the environment of a hot rolling pilot plant. In the experiments, it was also confirmed that the fiber delivery system could deliver Nd:YAG laser beam of 810 mJ/pulse and ultrasonic signals could be obtained successfully.

  16. Biofeedback control analysis using a synchronized system of two CCD video cameras and a force-plate sensor

    NASA Astrophysics Data System (ADS)

    Tsuruoka, Masako; Shibasaki, Ryosuke; Murai, Shunji

    1999-01-01

    The biofeedback control analysis of human movement has become increasingly important in rehabilitation, sports medicine and physical fitness. In this study, a synchronized system was developed for acquiring sequential data of a person's movement. The setup employs a video recorder system linked with two CCD video cameras and fore-plate sensor system, which are configured to stop and start simultaneously. The feedback control movement of postural stability was selected as a subject for analysis. The person's center of body gravity (COG) was calculated by measured 3-D coordinates of major joints using videometry with bundle adjustment and self-calibration. The raw serial data of COG and foot pressure by measured force plate sensor are difficult to analyze directly because of their complex fluctuations. Utilizing auto regressive modeling, the power spectrum and the impulse response of movement factors, enable analysis of their dynamic relations. This new biomedical engineering approach provides efficient information for medical evaluation of a person's stability.

  17. Experimental Fault Diagnosis in Systems Containing Finite Elements of Plate of Kirchoff by Using State Observers Methodology

    NASA Astrophysics Data System (ADS)

    Alegre, D. M.; Koroishi, E. H.; Melo, G. P.

    2015-07-01

    This paper presents a methodology for detection and localization of faults by using state observers. State Observers can rebuild the states not measured or values from points of difficult access in the system. So faults can be detected in these points without the knowledge of its measures, and can be track by the reconstructions of their states. In this paper this methodology will be applied in a system which represents a simplified model of a vehicle. In this model the chassis of the car was represented by a flat plate, which was divided in finite elements of plate (plate of Kirchoff), in addition, was considered the car suspension (springs and dampers). A test rig was built and the developed methodology was used to detect and locate faults on this system. In analyses done, the idea is to use a system with a specific fault, and then use the state observers to locate it, checking on a quantitative variation of the parameter of the system which caused this crash. For the computational simulations the software MATLAB was used.

  18. Evaluation of a head-repositioner and Z-plate system for improved accuracy of dose delivery.

    PubMed

    Charney, Sarah C; Lutz, Wendell R; Klein, Mary K; Jones, Pamela D

    2009-01-01

    Radiation therapy requires accurate dose delivery to targets often identifiable only on computed tomography (CT) images. Translation between the isocenter localized on CT and laser setup for radiation treatment, and interfractional head repositioning are frequent sources of positioning error. The objective was to design a simple, accurate apparatus to eliminate these sources of error. System accuracy was confirmed with phantom and in vivo measurements. A head repositioner that fixates the maxilla via dental mold with fiducial marker Z-plates attached was fabricated to facilitate the connection between the isocenter on CT and laser treatment setup. A phantom study targeting steel balls randomly located within the head repositioner was performed. The center of each ball was marked on a transverse CT slice on which six points of the Z-plate were also visible. Based on the relative position of the six Z-plate points and the ball center, the laser setup position on each Z-plate and a top plate was calculated. Based on these setup marks, orthogonal port films, directed toward each target, were evaluated for accuracy without regard to visual setup. A similar procedure was followed to confirm accuracy of in vivo treatment setups in four dogs using implanted gold seeds. Sequential port films of three dogs were made to confirm interfractional accuracy. Phantom and in vivo measurements confirmed accuracy of 2 mm between isocenter on CT and the center of the treatment dose distribution. Port films confirmed similar accuracy for interfractional treatments. The system reliably connects CT target localization to accurate initial and interfractional radiation treatment setup. PMID:19507401

  19. Surgical repair of a severely comminuted maxillary fracture in a dog with a titanium locking plate system.

    PubMed

    Illukka, E; Boudrieau, R J

    2014-01-01

    A four-year old male Labrador Retriever was admitted with head trauma after being hit by a car. The dog had sustained multiple nasal, maxillary, and frontal bone fractures that resulted in separation of the maxilla from the base of the skull. A severely comminuted left zygomatic arch fracture was also present. These fractures were all repaired using a point contact, locking titanium plate system, in a single procedure that resulted in excellent postoperative occlusion and immediate function. Healing was uneventful. Full function and excellent cosmetic appearance were evident 13 months after surgery. This case illustrates the ease of repair and the success of treatment of severely comminuted maxillofacial fractures by conforming to basic biomechanical principles taken directly from the human experience and successfully applied to the dog; these included multiple plate application along the buttresses and trusses of the facial skeleton. The plate fixation was applied to bridge the multiple fractures along the most appropriate lines of stress. The small size of the plates, and the ability to easily contour them to adapt to the bone surface in three-dimensions, allowed their placement in the most appropriate positions to achieve sufficient rigidity and lead to uncomplicated healing without any postoperative complications. PMID:25088587

  20. Mutual Inductance Problem for a System Consisting of a Current Sheet and a Thin Metal Plate

    NASA Technical Reports Server (NTRS)

    Fulton, J. P.; Wincheski, B.; Nath, S.; Namkung, M.

    1993-01-01

    Rapid inspection of aircraft structures for flaws is of vital importance to the commercial and defense aircraft industry. In particular, inspecting thin aluminum structures for flaws is the focus of a large scale R&D effort in the nondestructive evaluation (NDE) community. Traditional eddy current methods used today are effective, but require long inspection times. New electromagnetic techniques which monitor the normal component of the magnetic field above a sample due to a sheet of current as the excitation, seem to be promising. This paper is an attempt to understand and analyze the magnetic field distribution due to a current sheet above an aluminum test sample. A simple theoretical model, coupled with a two dimensional finite element model (FEM) and experimental data will be presented in the next few sections. A current sheet above a conducting sample generates eddy currents in the material, while a sensor above the current sheet or in between the two plates monitors the normal component of the magnetic field. A rivet or a surface flaw near a rivet in an aircraft aluminum skin will disturb the magnetic field, which is imaged by the sensor. Initial results showed a strong dependence of the flaw induced normal magnetic field strength on the thickness and conductivity of the current-sheet that could not be accounted for by skin depth attenuation alone. It was believed that the eddy current imaging method explained the dependence of the thickness and conductivity of the flaw induced normal magnetic field. Further investigation, suggested the complexity associated with the mutual inductance of the system needed to be studied. The next section gives an analytical model to better understand the phenomenon.

  1. The Proximity Force Approximation for the Casimir Energy of Plate-Sphere and Sphere-Sphere Systems in the Presence of One Extra Compactified Universal Dimension

    NASA Astrophysics Data System (ADS)

    Cheng, Hongbo

    2015-08-01

    The Casimir energies for plate-sphere system and sphere-sphere systems under PFA in the presence of one extra compactified universal dimension are analyzed. We find that the Casimir energy between a plate and a sphere in the case of sphere-based PFA is divergent. The Casimir energy of plate-sphere system in the case of plate-based PFA is finite and keeps negative. The extra-dimension corrections to the Casimir energy will be more manifest if the sphere is larger or farther away from the plate. It is shown that the negative Casimir energy for two spheres is also associated with the sizes of spheres and extra space. The larger spheres and the longer distance between them make the influence from the additional dimension stronger.

  2. Tectonic controls on the stratigraphic architecture and hydrocarbons systems of the Arabian Plate

    SciTech Connect

    Grabowski, G.J. Jr.; Norton, I.O.

    1995-12-31

    Arabian Platform sediments consist of major sequences separated by tectonically controlled unconformities. These tectonic events, at the plate margins, controlled the orientation and distribution of sedimentary facies on the stable platform. Eustacy and subsidence were the principle controls on the actual facies that formed.

  3. Preliminary design review package on air flat plate collector for solar heating and cooling system

    NASA Technical Reports Server (NTRS)

    1977-01-01

    Guidelines to be used in the development and fabrication of a prototype air flat plate collector subsystem containing 320 square feet (10-4 ft x 8 ft panels) of collector area are presented. Topics discussed include: (1) verification plan; (2) thermal analysis; (3) safety hazard analysis; (4) drawing list; (5) special handling, installation and maintenance tools; (6) structural analysis; and (7) selected drawings.

  4. Distal radius fractures-Design of locking mechanism in plate system and recent surgical procedures.

    PubMed

    Inagaki, Katsunori; Kawasaki, Keikichi

    2016-05-01

    Recently, many studies have emphasized the importance of the comprehension of detailed functional anatomy of the distal forearm and wrist joint, and their biomechanics. A significant contribution which yields good functional outcomes of surgical treatment was the development of the locking plate technology; this technology has facilitated the improvement of the surgical technique for the fixation of fractures. This article reviews the locking mechanism and design of the fixation screws and plate, and the details of the surgical technique including the double-tired subchondral support procedure as it is applied to common fractures. Arthroscopic-assisted surgical procedures can be used to reduce the intra-articular fracture fragments after realignment of the distal radius with the locking plate. This technique is also useful at the time of fixation to assess soft tissue injury. The combination of arthroscopic-assisted reduction and locking plate fixation is now indicated for AO type C2 and C3 intra-articular comminuted fractures. PMID:27006135

  5. Renewable liquid reflecting zone plate

    DOEpatents

    Toor, Arthur; Ryutov, Dmitri D.

    2003-12-09

    A renewable liquid reflecting zone plate. Electrodes are operatively connected to a dielectric liquid in a circular or other arrangement to produce a reflecting zone plate. A system for renewing the liquid uses a penetrable substrate.

  6. 100 Ma: the new frontier for quantitative global models of the coupled brittle-plates/viscous-mantle system.

    NASA Astrophysics Data System (ADS)

    Stotz, Ingo; Iaffaldano, Giampiero; Davies, Rhodri

    2014-05-01

    Over recent decades the body of geophysical datasets has grown substantially and rapidly. Ocean-floor observations now allow one to unravel past plate motions (for instance, in the North Atlantic and Indian Ocean over the past 20 Myr) at the unprecedented temporal resolution of about 1 Myr; and more data is anticipated in the near future. Similarly, our knowledge of continental evolution has grown due to advances in interpreting the records of orogeny and sedimentation. Altogether, these ever-growing datasets allow us to reconstruct the past evolution of Earth's lithospheric plates in greater detail than previously achieved. This is key to unravel the dynamics of geological processes, because reconstructed plate motions and their temporal changes are a powerful probe into the evolving balance of shallow- and deep-rooted forces. Such progress, however, is not yet matched by the ability to quantitatively model past plate-motion changes and, therefore to test hypotheses on the dominant geological controls. The main technical challenge is simulating the rheological behaviour of the plates/mantle system, which varies significantly from viscous to brittle. Classically, computer models for viscous mantle flow and for the piecewise motions of the brittle lithosphere have been developed separately. In recent years, coupling of these two independent classes of models has been pioneered, but only for neo-tectonic scenarios (i.e. past few Myr), and with some limitations as to accounting for the impact of evolving mantle-flow on plate motions. It is now timely to further advance the technical ability to simulate the coupled plates/mantle system through geological time (for instance throughout the Cenozoic and possibly the Cretaceous), and to use the growing body of geophysical data as a primary constraint on these quantitative models. In this project, we take steps in this direction. We build on previous work aimed at coupling two advanced codes for mantle flow and lithosphere

  7. Integrating research infrastructures for solid Earth science in Europe: the European Plate Observing System

    NASA Astrophysics Data System (ADS)

    Cocco, M.; Giardini, D.; EPOS-PP Consortium

    2011-12-01

    The European Plate Observing System (EPOS) coordinates and integrates the research infrastructures in the European-Mediterranean region, to promote innovative approaches for a better understanding of the physical processes controlling earthquakes, volcanic eruptions, tsunamis as well as those driving tectonics and Earth surface dynamics. The EPOS 30-year plan aims at integrating the currently scattered, but highly advanced European facilities into one distributed, coherent multidisciplinary Research Infrastructure allowing sustainable long-term Earth science research strategies and an effective coordinated European-scale monitoring facility for solid Earth dynamics taking full advantage of new e-science opportunities. EPOS has been approved by ESFRI (the European Scientific Forum for Research Infrastructures) as one of the critical European Research Infrastructures, and the EPOS Preparatory Phase is supported by the European Commission FP7 program. The cooperation between EPOS and similar US infrastructures (i.e. Earthscope) will be ensured by dedicated NSF-EC funding. EPOS is integrating data from permanent national and regional geophysical monitoring networks (seismological, GPS), with the observations from "in-situ" observatories (volcano observatories, in-situ fault zone test sites) and temporary-monitoring and laboratory experiments through a cyber-infrastructure for data mining and processing, and facilities for data integration, archiving and exchange. The vision is to integrate these existing research infrastructures in order to increase the accessibility and usability of multidisciplinary data from monitoring networks, laboratory experiments and computational simulations enhancing worldwide interoperability in Earth Science by establishing a leading integrated European infrastructure and services. More recently the EPOS and the satellite Earth Observation communities are collaborating in order to promote the integration of data from in-situ monitoring

  8. The EarthScope Plate Boundary Observatory Distributed Data Management System

    NASA Astrophysics Data System (ADS)

    Anderson, G.; Eakins, J.; Hodgkinson, K.; Matykiewicz, J.; Beldyk, M.; Blackman, B.; Boler, F.; Henderson, B.; Hoyt, B.; Lee, E.; Persson, E.; Smith, J.; Torrez, D.; Wright, J.; Jackson, M.; Meertens, C.

    2007-05-01

    EarthScope is an ambitious multi-year project funded by the United States National Science Foundation to explore the structure and dynamics of the North American continent using a wide range of geophysical methods. The Plate Boundary Observatory (PBO), being built by UNAVCO, is the geodetic component of EarthScope, and will comprise 880 continuous GPS stations, 103 borehole strainmeter stations, 28 tiltmeters, and five laser strainmeters; in addition, PBO will manage data for 209 existing GPS stations and 11 GPS stations installed by the USArray segment of EarthScope. As of February 2007, 561 of these stations have been installed. PBO data flow is managed from the PBO Boulder Network Operations Center (NOC), located at UNAVCO Headquarters. Automated systems at the NOC retrieve data from our stations at least daily, monitor the status of the network and alert operators to problems, and pass data on for analysis, archiving, and distribution. Real-time network status can be found at http:pboweb.unavco.org/soh_map. PBO's analysis centers generate high-quality derived data products from PBO raw data. Two centers, at Central Washington University and the New Mexico Institute of Mining and Technology, process raw GPS data to produce initial PBO GPS products including network solutions and station position time series, andthese products are combined by the Analysis Center Coordinator at MIT to produce the official PBO GPS products. Two analysis centers, at UNAVCO's Socorro office and the University of California, San Diego, process data from the PBO borehole and laser strainmeter networks and produce cleaned time series of shear, areal, and linear strain, Earth tides, pore fluid pressure, and other parameters. The UNAVCO Facility archives and distributes all PBO GPS data products and runs a secondary archive offsite; to date, these centers hold more than 2.5 TB of PBO products. The IRIS Data Management Center and Northern California Earthquake Data Center archive and

  9. Management of pediatric mandibular fractures using bioresorbable plating system – Efficacy, stability, and clinical outcomes: Our experiences and literature review

    PubMed Central

    Singh, Mahinder; Singh, R.K.; Passi, Deepak; Aggarwal, Mohit; Kaur, Guneet

    2015-01-01

    Aims The purpose of this study was to determine the efficacy and stability of the biodegradable fixation system for treatment of mandible fractures in pediatric patients by measuring the bite force. Methods Sixty pediatric patients with mandibular fractures (36 males, 24 females) were included in this study. The 2.5-mm resorbable plates were adapted along Champy's line of ideal osteosynthesis and secured with four 2.5 mm diameter monocortical resorbable screws, 8 mm in length. All patients were followed for 10 months. Clinical parameters, such as soft tissue infection, nonunion, malunion, implant exposure, malocclusion, nerve injury, and bite force for stability, were prospectively assessed. Results Adequate fixation and primary bone healing was achieved in 100% of the cases. Six minor complications (10%) were observed: 2 soft tissue infections (3%), 1 plate dehiscence (2%), 1 malocclusion (2%), and 2 paresthesia (3%). Conclusion 2.5-mm resorbable plating system along Champy's line of ideal osteosynthesis is a good treatment modality for mandible fractures in pediatric patients. PMID:27195206

  10. A high-throughput system for two-hybrid screening based on growth curve analysis in microtiter plates.

    PubMed

    Diaz-Camino, Claudia; Risseeuw, Eddy P; Liu, Enwu; Crosby, William L

    2003-05-15

    The yeast two-hybrid system is a powerful tool for identifying novel protein-protein interactions. In general, biochemical marker genes such as lacZ are exploited for indirect quantification of the interaction, and commonly involve the conduct of rather laborious beta-galactosidase assays. This paper describes a simple alternative method based on growth curve analysis of yeast cultures that is amenable to microtiter plate format, and therefore allows the quantification of large numbers of yeast two-hybrid combinations. The analyzed results of yeast cultures grown in microtiter plates were compared with those obtained from the classical beta-galactosidase assay. We conclude that the method presented here is reproducible, of equal or greater sensitivity than the beta-galactosidase assay, and can be further adapted for application to the conduct of large-scale, automated yeast two-hybrid experiments. PMID:12711337

  11. Experimental Simulation of Active Control With On-line System Identification on Sound Transmission Through an Elastic Plate

    NASA Technical Reports Server (NTRS)

    1998-01-01

    An adaptive control algorithm with on-line system identification capability has been developed. One of the great advantages of this scheme is that an additional system identification mechanism such as an additional uncorrelated random signal generator as the source of system identification is not required. A time-varying plate-cavity system is used to demonstrate the control performance of this algorithm. The time-varying system consists of a stainless-steel plate which is bolted down on a rigid cavity opening where the cavity depth was changed with respect to time. For a given externally located harmonic sound excitation, the system identification and the control are simultaneously executed to minimize the transmitted sound in the cavity. The control performance of the algorithm is examined for two cases. First, all the water was drained, the external disturbance frequency is swept with 1 Hz/sec. The result shows an excellent frequency tracking capability with cavity internal sound suppression of 40 dB. For the second case, the water level is initially empty and then raised to 3/20 full in 60 seconds while the external sound excitation is fixed with a frequency. Hence, the cavity resonant frequency decreases and passes the external sound excitation frequency. The algorithm shows 40 dB transmitted noise suppression without compromising the system identification tracking capability.

  12. Fixation of sternal fracture using absorbable plating system, three years follow-up

    PubMed Central

    Katballe, Niels; Pilegaard, Hans

    2015-01-01

    Sternal fractures occur due to severe chest wall trauma in a small number of patients. They are often conservatively treated. The surgical intervention, although controversial, is indicated in case of deformity, severe pain, and ventilatory complications. We report the first case where absorbable plate has been used to fix a traumatic fracture in a 42-year-old female. After 3 years, the patient is still free of symptoms and CT scanning reveals intact sternal bone structure. PMID:26101659

  13. First epoch geodetic measurements with the Global Positioning System across the northern Caribbean plate boundary zone

    NASA Technical Reports Server (NTRS)

    Dixon, T. H.; Gonzalez, G.; Lichten, S. M.; Katsigris, E.

    1991-01-01

    The first geodetic survey across the northern Caribbean plate boundary zone with GPS was conducted in June 1986. Baseline vectors defined by the six-station regional GPS network ranged from 170 to 1260 km in length. Repeatability of independent daily baseline estimates was better than 8 mm plus 1.3 parts in 10 to the 8th of baseline length for horizontal components. The wet tropospheric path delay during the experiment was both high, sometimes exceeding 30 cm at zenith, and variable, sometimes exceeding 5 cm variation over several hours. Successful carrier phase cycle ambiguity resolution (bias fixing) could not be achieved prior to construction of a regional troposphere model. With optimum troposphere treatment and single-day orbital arcs, most biases on baselines were resolved up to about 550 km in length. With multiday orbital arcs most biases in the network were resolved regardless of baseline length. The results suggest that constraints on plate-boundary zone deformation in the Greater Antilles, and on the North America-Caribbean relative plate motion vector, can be obtained with a series of GPS experiments spanning less than 10 and 15 years, respectively.

  14. Understanding plate-motion changes over the past 100 Myr with quantitative models of the coupled lithosphere/mantle system

    NASA Astrophysics Data System (ADS)

    Stotz, Ingo; Iaffaldano, Giampiero; Rhodri Davies, D.

    2015-04-01

    The volume of geophysical datasets has grown substantially over recent decades. Our knowledge of continental evolution has increased due to advances in interpreting the records of orogeny and sedimentation. Ocean-floor observations now allow one to resolve past plate motions (e.g. in the North Atlantic and Indian Ocean over the past 20 Myr) at temporal resolutions of about 1 Myr. Altogether, these ever-growing datasets allow us to reconstruct the past evolution of Earth's lithospheric plates in greater detail. This is key to unravelling the dynamics of geological processes, because plate motions and their temporal changes are powerful probe into the evolving force balance between shallow- and deep-rooted processes. However, such progress is not yet matched by the ability to quantitatively model past plate-motion changes and, therefore, to test hypotheses on the dominant controls. The main technical challenge is simulating the rheological behaviour of the lithosphere/mantle system, which varies significantly from viscous to brittle. Traditionally computer models for viscous mantle flow on the one hand, and for the motions of the brittle lithosphere on the other hand, have been developed separately. Coupling of these two independent classes of models has been accomplished only for neo-tectonic scenarios, without accounting for the impact of time-evolving mantle-flow (e.g. Iaffaldano and Bunge 2009). However, we have built a coupled model to simulate the lithosphere/mantle system (using SHELLS and TERRA, respectively) through geological time, and to exploit the growing body of geophysical data as a primary constraint on these quantitative models. TERRA is a global spherical finite-element code for mantle convection (e.g. Baumgardner 1985, Bunge et al. 1996, Davies et al. 2013), whilst SHELLS is a thin-sheet finite-element code for lithosphere dynamics (e.g. Bird 1998). Our efforts are focused, in particular, on achieving the technical ability to: (i) simulate the

  15. Miniaturized plate readers for low-cost, high-throughput phenotypic screening.

    PubMed

    Jensen, Paul A; Dougherty, Bonnie V; Moutinho, Thomas J; Papin, Jason A

    2015-02-01

    We present a miniaturized plate reader for measuring optical density in 96-well plates. Our standalone reader fits in most incubators, environmental chambers, or biological containment suites, allowing users to leverage their existing laboratory infrastructure. The device contains no moving parts, allowing an entire 96-well plate to be read several times per second. We demonstrate how the fast sampling rate allows our reader to detect small changes in optical density, even when the device is placed in a shaking incubator. A wireless communication module allows remote monitoring of multiple devices in real time. These features allow easy assembly of multiple readers to create a scalable, accurate solution for high-throughput phenotypic screening. PMID:25366331

  16. Miniaturized Plate Readers for Low-Cost, High-Throughput Phenotypic Screening

    PubMed Central

    Jensen, Paul A.; Dougherty, Bonnie V.; Moutinho, Thomas J.

    2015-01-01

    We present a miniaturized plate reader for measuring optical density in 96-well plates. Our standalone reader fits in most incubators, environmental chambers, or biological containment suites, allowing users to leverage their existing laboratory infrastructure. The device contains no moving parts, allowing an entire 96-well plate to be read several times per second. We demonstrate how the fast sampling rate allows our reader to detect small changes in optical density, even when the device is placed in a shaking incubator. A wireless communication module allows remote monitoring of multiple devices in real time. These features allow easy assembly of multiple readers to create a scalable, accurate solution for high-throughput phenotypic screening. PMID:25366331

  17. Use of a Fluorometric Imaging Plate Reader in high-throughput screening

    NASA Astrophysics Data System (ADS)

    Groebe, Duncan R.; Gopalakrishnan, Sujatha; Hahn, Holly; Warrior, Usha; Traphagen, Linda; Burns, David J.

    1999-04-01

    High-throughput screening (HTS) efforts at Abbott Laboratories have been greatly facilitated by the use of a Fluorometric Imaging Plate Reader. The FLIPR consists of an incubated cabinet with integrated 96-channel pipettor and fluorometer. An argon laser is used to excite fluorophores in a 96-well microtiter plate and the emitted fluorometer. An argon laser is used to excite fluorophores in a 96-well microtiter plate and the emitted fluorescence is imaged by a cooled CCD camera. The image data is downloaded from the camera and processed to average the signal form each well of the microtiter pate for each time point. The data is presented in real time on the computer screen, facilitating interpretation and trouble-shooting. In addition to fluorescence, the camera can also detect luminescence form firefly luciferase.

  18. Favorable locations for piezo actuators in plates with good control effectiveness and minimal change in system dynamics

    NASA Astrophysics Data System (ADS)

    Dhuri, K. D.; Seshu, P.

    2007-12-01

    Placement and sizing of piezo actuators is normally based on control effectiveness. However, retrofitting of piezoelectric actuators alters the inherent stiffness/mass properties of the parent structure. In rotating structures, the additional mass due to piezo patches contributes to the centrifugal stiffening force. The parent structure is originally designed to have a certain natural frequency spectrum in relation to the disturbance excitation. In the event of failure of the active system, the dynamics of the structure with piezos (now rendered passive) will therefore become significant. Thus it will be helpful to determine locations for mounting piezo patches based on minimal natural frequency change yet with good control authority. In this study, a finite element based procedure for plate structures is presented. Favorable locations for mounting piezos based on minimal natural frequency changes are iteratively evolved from an initial configuration wherein the whole plate is covered with piezos. A modal controllability approach has been used for finding piezo mounting locations from a good controllability perspective. The procedure is demonstrated for simply supported square, swept-back, circular and rotating rectangular plates considering the first four modes.

  19. Numerical modeling of outer rise deformation in the Tonga subduction system: Coupling between outer rise deformation, slab weakening and plate velocities

    NASA Astrophysics Data System (ADS)

    Naliboff, J. B.; Billen, M. I.; Gerya, T.; Saunders, J. K.

    2012-12-01

    During subduction, bending and flexure of oceanic lithosphere generates a topographic bulge seaward of the trench known as the outer rise, which commonly exhibits extensional deformation attributed to slab pull forces and bending stresses. The resulting brittle and viscous deformation may play a significant role in long-term geodynamic processes by limiting the ability of subducted oceanic lithosphere to act as a stress guide driving surface plate motions through slab pull. Recent numerical studies provide varying estimates of slab pull's contribution to surface plate motions [e.g., van Summeren et al. 2012, Ghosh & Holt 2012], while observational constraints suggest old oceanic lithosphere may weaken by 3-4 orders of magnitude as it bends and descends beneath the overriding plate [Arredondo & Billen, 2012]. Preliminary numerical models of outer rise deformation during oceanic-continental convergence (40 Myr oceanic lithosphere) exhibit 10x-150x viscous weakening in the upper plate near the trench, with time-dependent variations related to both changes in slab depth and downgoing-overriding plate coupling (Naliboff et al., in prep). In order to more closely examine the relationship between outer rise deformation, geophysical observations and plate velocities, we consider 2D subduction models of the Tonga subduction system where flow will be strictly driven by upper mantle slab buoyancy as defined by the Slab1.0 model [Hayes et al. 2012]. The resulting subducting plate deformation patterns are compared to observations of outer rise faulting, elastic thickness measurements and outer rise seismicity. While keeping buoyancy forces fixed, we will examine the role of brittle rheology, hydration and downgoing-overriding plate coupling in patterns of subducting plate deformation. These results will provide improved physical understanding of the relationship between slab pull, plate velocities and downgoing plate weakening, and a basis for future work examining the role of

  20. A Module Experimental Process System Development Unit (MEPSDU). [flat plate solar arrays

    NASA Technical Reports Server (NTRS)

    1981-01-01

    The development of a cost effective process sequence that has the potential for the production of flat plate photovoltaic modules which meet the price goal in 1986 of 70 cents or less per Watt peak is described. The major accomplishments include (1) an improved AR coating technique; (2) the use of sand blast back clean-up to reduce clean up costs and to allow much of the Al paste to serve as a back conductor; and (3) the development of wave soldering for use with solar cells. Cells were processed to evaluate different process steps, a cell and minimodule test plan was prepared and data were collected for preliminary Samics cost analysis.

  1. Building America Case Study: Advanced Extended Plate and Beam Wall System in a Cold-Climate House, Mount Joy, Pennsylvania

    SciTech Connect

    2016-01-01

    This report presents the design and evaluation of a innovative wall system. This highly insulated (high-R) light-frame wall system for use above grade in residential buildings is referred to as Extended Plate & Beam (EP&B). The EP&B design is the first of its kind to be featured in a new construction test house (NCTH) for the DOE Building America program. The EP&B wall design integrates standard building methods and common building products to construct a high-R wall that minimizes transition risks and costs to builders. The EP&B design combines optimized framing with integrated rigid foam sheathing to increase the wall system's R-value and reduce thermal bridging. The foam sheathing is installed between the wall studs and structural wood sheathing. The exterior wood sheathing is attached directly to a framing extension formed by extended top and bottom plates. The exterior wood sheathing can dry to the exterior and provides bracing, a clear drainage plane and flashing surface for window and door openings, and a nailing surface for siding attachment. With support of the DOE Building America program, Home Innovation Research Labs partnered with Lancaster County Career and Technology Center (LCCTC) to build a NCTH in Lancaster, PA to demonstrate the EP&B wall design in a cold climate (IECC climate zone 5A). The results of the study confirmed the benefits of the systems and the viability of its integration into the house construction process.

  2. Peen plating

    NASA Technical Reports Server (NTRS)

    Babecki, A. J. (Inventor); Haehner, C. L.

    1973-01-01

    A process for metal plating which comprises spraying a mixture of metallic powder and small peening particles at high velocity against a surface is described. The velocity must be sufficient to impact and bond metallic powder onto the surface. In the case of metal surfaces, the process has as one of its advantages providing mechanical working (hardening) of the surface simultaneously with the metal plating.

  3. A wearable force plate system for the continuous measurement of triaxial ground reaction force in biomechanical applications

    NASA Astrophysics Data System (ADS)

    Liu, Tao; Inoue, Yoshio; Shibata, Kyoko

    2010-08-01

    The ambulatory measurement of ground reaction force (GRF) and human motion under free-living conditions is convenient, inexpensive and never restricted to gait analysis in a laboratory environment and is therefore much desired by researchers and clinical doctors in biomedical applications. A wearable force plate system was developed by integrating small triaxial force sensors and three-dimensional (3D) inertial sensors for estimating dynamic triaxial GRF in biomechanical applications. The system, in comparison to existent systems, is characterized by being lightweight, thin and easy-to-wear. A six-axial force sensor (Nitta Co., Japan) was used as a verification measurement device to validate the static accuracy of the developed force plate. To evaluate the precision during dynamic gait measurements, we compared the measurements of the triaxial GRF and the center of pressure (CoP) by using the developed system with the reference measurements made using a stationary force plate and an optical motion analysis system. The root mean square (RMS) differences of the two transverse components (x- and y-axes) and the vertical component (z-axis) of the GRF were 4.3 ± 0.9 N, 6.0 ± 1.3 N and 12.1 ± 1.1 N, respectively, corresponding to 5.1 ± 1.1% and 6.5 ± 1% of the maximum of each transverse component and 1.3 ± 0.2% of the maximum vertical component of GRF. The RMS distance between the two systems' CoP traces was 3.2 ± 0.8 mm, corresponding to 1.2 ± 0.3% of the length of the shoe. Moreover, based on the results of the assessment of the influence of the system on natural gait, we found that gait was almost never affected. Therefore, the wearable system as an alternative device can be a potential solution for measuring CoP and triaxial GRF in non-laboratory environments.

  4. European Plate Observing System - the Arctic dimension and the Nordic collaboration

    NASA Astrophysics Data System (ADS)

    Atakan, K.; Heikkinen, P.; Juhlin, C.; Thybo, H.; Vogfjord, K.

    2012-04-01

    Within the framework of the EPOS project, Nordic interests are significant, not only in fundamental scientific issues related to geodynamic processes, but also in terms of the application of these to several central problems such as, hydrocarbon exploration and production including the related environmental issues, CO2 storage (or other toxic waste repositories) in geological formations, geothermal energy (natural and hot-dry rock) utilization and mining, geohazards (earthquakes, landslides and volcanic eruptions) and their consequences to the society. The Arctic dimension including Fennoscandia, the northern North Atlantic and the Arctic Sea constitutes an area of considerable geographical extent within the European plate. The region also contains a significant part of the European plate boundary submerged under the North Atlantic and the Arctic sea, where geodynamic processes such as rifting and fracturing are especially energetic. In particular, where the plate boundary is exposed on land in the South Iceland seismic zone, large earthquakes are frequently observed including two Mw6.5 events in 2000 and one Mw6.3 event in 2008. But, seismic hazard is not confined to the plate boundary. Significant intra-plate earthquakes have recently occurred in the region (Mw6.1 in the continental shelf near Spitsbergen in 2008, Mw5.0 in Southern Sweden in 2008, Mw5.2 near Kaliningrad in 2004) showing that there is considerable seismic hazard in the region. In addition, submarine landslide earthquakes are always of concern due to possible tsunami generation. Volcanic activity occurs on the plate boundary and is particularly strong in the rift zones of Iceland, where on average two volcanic eruptions occur per decade. subaerial volcanic eruptions also occur on Jan Mayen island, farther north on the Mid Atlantic ridge. Together, the Danish seismic network in Greenland, the Norwegian seismic arrays and national network traversing the length of Norway and the Icelandic seismic and

  5. Matrix based system of isotretinoin as nail lacquer to enhance transungal delivery across human nail plate.

    PubMed

    Joshi, Monika; Sharma, Vijay; Pathak, Kamla

    2015-01-15

    The project was aimed at development of isotretinoin nail lacquer and assessment of its penetration efficiency across human nail plate. Preliminary studies (hydration enhancement factor and SEM) aided the selection of thioglycolic acid as permeation and eugenol was selected as local anesthetic in the formulation. The nail lacquer was optimized by 3(2) factorial design and a total of nine formulations were prepared and screened. In vitro adhesion and ex vivo permeation (cumulative drug permeation per unit area (CDP/A) = 6.61 ± 0.57 mg/cm(2)) across bovine hoof guided the selection of F3 as optimized formulation that was improvised. Viscosity adjustments to improve handling characteristics were affected by incorporation of ethyl cellulose (6%; F3M1) that scaled the viscosity to 312.681 cp and insignificantly (p > 0.05) affected CDP/A (6.32 ± 0.45 mg/cm(2)). In comparison to marketed preparation (Retino-A cream) F3M1 afforded two fold increase in CDP/A. The permeation characteristics were defined by Higuchi model (r(2) = 0.964) and flux value of 176 μg/cm(2)/h. Confocal laser scanning microscopy, after 72 h of nail lacquer application, revealed extensive distribution of the fluorescent tracer across the human nail plate in comparison to control that was confined to the top layer. Conclusively, an efficacious and stable nail lacquer of isotretinoin was developed for potential clinical topical use to target the drug to nail bed in treatment of nail psoriasis. PMID:25445993

  6. Study of bioadhesion on a flat plate with a yeast/glass model system.

    PubMed

    Mercier-Bonin, M; Ouazzani, K; Schmitz, P; Lorthois, S

    2004-03-15

    The attachment of microorganisms to a surface is a critical first step of biofilm fouling in membrane processes. The shear-induced detachment of baker's yeast in adhesive contact with a plane glass surface was thus experimentally studied, using a specially designed shear stress flow chamber. The yeast was marketed either as rod-shaped pellets (type I yeast) or as spherical pellets (type II yeast). A complete series of experiments for measuring the shear stress necessary to detach a given proportion of individual yeast cells of type I or II was performed under different environmental conditions (ionic strength, contact time). In parallel, the surface physicochemical properties of the cells (surface charge, hydrophobicity, and electron donor and electron acceptor components) were determined. For the first type of yeast cells, which were rather hydrophilic, adhesion to the glass plate was weak. This was due to both electrostatic effects and hydrophilic repulsion. Furthermore, adhesion was not sensitive to any variation of the ionic strength. For yeast of the second type, adhesion was drastically increased. This could be explained by their physicochemical surface properties and especially their hydrophobic and electron acceptor components, which caused strong attractive van der Waals and Lewis acid-base interactions, counterbalancing the electrostatic repulsion. For increasing ionic strengths, adhesion was greater, due to lower electrostatic repulsion. The results were quantified through the definition of a critical wall shear stress ( tau w 50% ) required to detach 50% of the yeast cells initially deposited on the glass surface. The influence of the contact time was also evaluated and it was shown that, whatever the type of yeast, macromolecules such as proteins were released into the extracellular medium due to cell lysis and could contribute to the formation of a conditioning film. As a result, the cells were more strongly stuck to the glass plate. PMID:14972611

  7. Optimum exposure conditions for computed radiography depending on fixed pattern noise and efficiency of imaging plate-scanner systems

    SciTech Connect

    Ewert, U.; Heyne, K.; Zscherpel, U.; Jechow, M.; Bavendiek, K.

    2011-06-23

    The presently active standards on Computed Radiography (CR) need a major revision. It was observed by many users that the image quality for class B of EN 14784-2 is not achievable under the same exposure conditions as used for film exposure. A mathematical model was developed and tested, which allows the calculation of the image quality, proven by image quality indicators (IQI), depending on the fixed pattern noise and the efficiency of the used imaging plate (IP) scanner system. All tested IP scanner systems provide a fixed correlation between the measured signal/noise ratio (SNR) and the grey values in the digital images. The maximum achievable SNR{sub max} depends on the fixed pattern noise of the plate (high dose limit). Depending on the exposure dose an optimum visibility of IQIs can be predicted by calculation and measured considering the attenuation coefficient for calculation of the contrast/noise ratio (CNR). The diameter of the just visible wire is proportional to 1/sqrt(CNR). The optimum tube voltage for best visibility of IQIs and maximum CNR depend on the exposure dose. The optimum tube voltage for best visibility is achieved only at exposures with high dose. A dose dependant optimal tube voltage was not observed for film radiography.

  8. A Microplate-Based System as In Vitro Model of Biofilm Growth and Quantification.

    PubMed

    Vandecandelaere, Ilse; Van Acker, Heleen; Coenye, Tom

    2016-01-01

    We describe a 96-well microtiter plate-based system as an in vitro model for biofilm formation and quantification. Although in vitro assays are artificial systems and thus significantly differ from in vivo conditions, they represent an important tool to evaluate biofilm formation and the effect of compounds on biofilms. Stainings to evaluate the amount of biomass (crystal violet staining) and the number of metabolically active cells (resazurin assay) are discussed and specific attention is paid to the use of this model to quantify persisters in sessile populations. PMID:26468099

  9. Ionospheric plasma flow about a system of electrically biased flat plates. M.S. Thesis - Cleveland State Univ. Final Report

    NASA Technical Reports Server (NTRS)

    Herr, Joel L.

    1993-01-01

    The steady state interaction of two electrically biased parallel plates immersed in a flowing plasma characteristic of low earth orbit is studied numerically. Fluid equations are developed to describe the motion of the cold positively charged plasma ions, and are solved using finite-differences in two dimensions on a Cartesian grid. The behavior of the plasma electrons is assumed to be described by the Maxwell-Boltzmann distribution. Results are compared to an analytical and a particle simulation technique for a simplified flow geometry consisting of a single semi-infinite negatively biased plate. Comparison of the extent of the electrical disturbance into the flowing plasma and the magnitude of the current collected by the plate is very good. The interaction of two equally biased parallel plates is studied as a function of applied potential. The separation distance at which the current collected by either plate decreases by five and twenty percent is determined as a function of applied potential. The percent decreases were based on a non-interacting case. The decrease in overall current is caused by a decrease in ionic density in the region between the plates. As the separation between the plates decreases, the plates collect the ions at a faster rate than they are supplied to the middle region by the oncoming plasma flow. The docking of spacecraft in orbit is simulated by moving two plates of unequal potential toward one another in a quasi-static manner. One plate is held at a large negative potential while the other floats electrically in the resulting potential field. It is found that the floating plate does not charge continuously negative as it approaches the other more negatively biased plate. Instead, it charges more and then less negative as ionic current decreases and then increases respectively upon approach. When the two plates come into contact, it is expected that the electrically floating plate will charge rapidly negative to a potential near that of

  10. Experimental Non-Contact Evaluation of Delamination in CFRP Composite Plates by Laser Air-Coupled Detection Ultrasonic System

    NASA Astrophysics Data System (ADS)

    Lee, Seung-Joon; Lee, Joon-Hyun; Byun, Joon-Hyung

    The objective of this research is to develop non-contact and real time inspection technique based on laser generated ultrasound for evaluating near-surface delamination in Carbon/Epoxy composite fabricated from automated fiber placement system. In this study, A hybrid laser generation/air-coupled detection ultrasonic system for detection and visualization of delamination in composite plates with simulated delamination of the area of 20 mm × 20 mm between the first and the second layer. Optical fiberized Nd:YAG pulse laser (532 nm, 32 mJ) with linear slit array is used to generate ultrasonic guided wave in unidirectional CFRP specimen (24 plies, 2.85 mm thickness). The characteristic of time domain waveform and frequency spectrum of guided wave is discussed. Two- dimensional images are obtained from these characteristics. The convergence of received signal using the pitch-catch and the scattering-reflection technique is discussed.

  11. A multiple-system study of the geochemical evolution of the mantle with force-balanced plates and thermochemical effects

    NASA Astrophysics Data System (ADS)

    Brandenburg, J. P.; Hauri, Erik H.; van Keken, Peter E.; Ballentine, Chris J.

    2008-11-01

    Here, multiple isotope systems are tracked simultaneously in models of mantle convection and it is show that this can provide powerful constraints on the role of oceanic crust recycling in the development of isotopic end-member compositions. The dynamical models are based on high-resolution cylindrical calculations with force-balanced plates and variable chemical density. The dynamic results span a parameter space of variable realistic excess crustal density compared to experimental estimates and convective vigor measured by plate velocities and surface heat flow. Isotope geochemistry is then modeled for the U-Th-Pb, Sm-Nd, Rb-Sr, and Re-Os isotope systems. The role of a dense crustal layer in development of a HIMU-isotope signature is confirmed. The extraction of continental crust is found to be essential for the formation of all isotope compositional end-members, including HIMU. This extraction is implemented as an ad-hoc process secondary to partial melting at mid-ocean ridges and constrained by estimated isotopic abundances in the present-day crust. Whereas previous studies generated mantle isotopic arrays that spanned DMM-HIMU, the additional isotope systems in this analysis indicate that enrichment purely from ancient oceanic crust may also generate an EM-I component without invoking the subduction of sediment. In this case, the EM-I signature may be indicative of mantle enriched by oceanic crust produced before 2.25 Byr, while the HIMU signature indicates enrichment by oceanic crust extracted more recently. However, it is found to be difficult to maintain a true DMM isotopic end member in Sr-Nd isotope space when significantly enriched end-members are present. This may highlight the sensitivity of the Rb-Sr system to mass exchange between the upper and lower mantle.

  12. Loads specification and embedded plate definition for the ITER cryoline system

    NASA Astrophysics Data System (ADS)

    Badgujar, S.; Benkheira, L.; Chalifour, M.; Forgeas, A.; Shah, N.; Vaghela, H.; Sarkar, B.

    2015-12-01

    ITER cryolines (CLs) are complex network of vacuum-insulated multi and single process pipe lines, distributed in three different areas at ITER site. The CLs will support different operating loads during the machine life-time; either considered as nominal, occasional or exceptional. The major loads, which form the design basis are inertial, pressure, temperature, assembly, magnetic, snow, wind, enforced relative displacement and are put together in loads specification. Based on the defined load combinations, conceptual estimation of reaction loads have been carried out for the lines located inside the Tokamak building. Adequate numbers of embedded plates (EPs) per line have been defined and integrated in the building design. The finalization of building EPs to support the lines, before the detailed design, is one of the major design challenges as the usual logic of the design may alter. At the ITER project level, it was important to finalize EPs to allow adequate design and timely availability of the Tokamak building. The paper describes the single loads, load combinations considered in load specification and the approach for conceptual load estimation and selection of EPs for Toroidal Field (TF) Cryoline as an example by converting the load combinations in two main load categories; pressure and seismic.

  13. Deposition mechanisms of TiO2 nanoparticles in a parallel plate system.

    PubMed

    Chowdhury, Indranil; Walker, Sharon L

    2012-03-01

    In this study, a microscope-based technique was utilized to understand the fundamental mechanisms involved in deposition of TiO(2) nanoparticles (TNPs). Transport and deposition studies were conducted in a parallel plate (PP) flow chamber with TNP labeled with fluorescein isothiocyanate (FITC) for visualization. Attachment of FITC-labeled TNPs on surfaces is a function of a combination of parameters, including ionic strength (IS), pH and flowrate. Significantly higher deposition rates were observed at pH 5 versus pH 7. This is attributed to the conditions being chemically favorable for deposition at pH 5 as compared to pH 7, as predicted by DLVO theory. Additionally, deposition rates at pH 5 were reduced with IS below 10 mM due to the decrease in range of electrostatic attractive forces. Above 10 mM, aggregate size increased, resulting in higher deposition rates. At pH 7, no deposition was observed below 10 mM and above this concentration, deposition increased with IS. The impact of flowrate was also observed, with decreasing flowrate leading to greater deposition due to the reduction in drag force acting on the aggregate (regardless of pH). Comparisons between experimental and theoretical approximations indicate that non-DLVO type forces also play a significant role. This combination of observations suggest that the deposition of these model nanoparticles on glass surfaces was controlled by a combination of DLVO and non-DLVO-type forces, shear rate, aggregation state, and gravitational force acting on TNPs. PMID:22226475

  14. Tectono-magmatic response to major convergence changes in the North Patagonian suprasubduction system; the Paleogene subduction-transcurrent plate margin transition

    NASA Astrophysics Data System (ADS)

    Aragón, Eugenio; D'Eramo, Fernando; Castro, Antonio; Pinotti, Lucio; Brunelli, Daniele; Rabbia, Osvaldo; Rivalenti, Giorgio; Varela, Ricardo; Spakman, Wim; Demartis, Manuel; Cavarozzi, Claudia E.; Aguilera, Yolanda E.; Mazzucchelli, Maurizio; Ribot, Alejandro

    2011-08-01

    The southern and central Andes reflect significant along-strike differences of tectonic activity, including shortening, alternating flat-to-normal subduction styles and magmatism. In northern Patagonia, the subduction/supra-subduction system, fore arc, arc and back arc basins developed in an extensional setting during the Paleogene. This was accompanied by landward migration of calc-alkalic magmatism which changed to synextensional bimodal volcanism of rhyolitic ignimbrites and interbedded tholeiitic and alkalic basalts. These Paleogene events occurred during a time when the Farallon-Aluk active ridge reached the South American plate, and the Farallon plate subduction was interrupted. They represent a new tectonic regime, characterized by a transcurrent plate margin. The presence in the back arc of a rigid lithospheric block of 100,000 km 2 represented by the North Patagonian Massif focused the rotation of the coastal blocks. This resulted in the development of two Paleogene extensional regions to the north and south, respectively, of the Massif and replaced the former back arc. Plate rearrangement caused by the inauguration of the Nazca plate and its regime of orthogonal subduction at the beginning of the Miocene, re-established typical calc-alkaline arc magmatism at the former upper Cretaceous arc locus. Present seismic activity in the subducted plate and tomographic modeling of p-wave velocity anomalies in the upper mantle also suggest the presence of a subduction gap that lasted for most of the Paleogene in northern Patagonia.

  15. Digital Archive of UkrVO: first results of MAO NASU Solar System Bodies photographic plate processing

    NASA Astrophysics Data System (ADS)

    Ivanov, G.; Pakuliak, L.; Shatokhina, S.; Yizhakevych, E.; Kazantseva, L.; Andruk, V.

    The digitizing and processing of photographic plates with the images of the outer planets and their satellites from the archive collections of MAO NASU and AO of Kiev university included into the UkrVO Joint Digital Archive (JDA) have been made. Plates were obtained in the last half of the 20th century. The digitizing of JDA archive plates and inclusion of plate preview images into GPA database has been under way, using two models of flatbed scanners: Microtek ScanMaker 9800XL TMA and Epson Expression 10000XL. The database with metadata of plates is allocated on the computational resources of MAO NASU (http://gua.db.ukr-vo.org). Plates have been scanned at 16-bits grey dynamic range, with a resolution of 1200-1600 dpi, and saved in TIFF format. Linear dimensions of images are up to 13 thousand pixels (for plates 30.30 cm). The astrometric and photometric calibration procedures have been done in the LINUX-MIDASROMAFOT environment and Tycho-2 as reference with the image processing procedure specially developed for digitized images of huge linear dimensions on the basis of the image inherent traits. First results of digitized plate processing give the rms errors of 10 and 20 mas for RA, DEC respectively. (O-C) for plates with Pluto in comparison to JPL PLU021.DE405 has been derived of 140(RA) and 270(DEC) mas.

  16. Anatomy of an extinct magmatic system along a divergent plate boundary: Alftafjordur, Iceland

    NASA Astrophysics Data System (ADS)

    Urbani, S.; Trippanera, D.; Porreca, M.; Kissel, C.; Acocella, V.

    2015-08-01

    Recent rifting episodes highlight the role of magmatic systems with propagating dikes on crustal spreading. However, our knowledge of magmatic systems is usually limited to surface observations and geophysical data. Eastern Iceland allows direct access to extinct and eroded deeper magmatic systems. Here we collected field structural and AMS (anisotropy of magnetic susceptibility) data on 187 and 19 dikes, respectively, in the 10-12 Ma old Alftafjordur magmatic system. At a paleodepth of ~1.5 km, the extension due to diking is at least 1-2 orders of magnitude larger than that induced by regional tectonics, confirming magmatism as the key mechanism for crustal spreading. This magma-induced extension, inferred from the aspect ratio of the magmatic system, was of ~8 mm/yr, lower than the present one. AMS data suggest that most of dikes have geometrically normal fabric, at least at the margins, consistent with prevalent subvertical magma flow and propagation.

  17. A new method for analytical solution of inplane free vibration of rectangular orthotropic plates based on the analysis of infinite systems

    NASA Astrophysics Data System (ADS)

    Papkov, S. O.

    2016-05-01

    In this paper, a new method for in-plane free vibration analysis of rectangular orthotropic plate is presented. The cases for completely clamped and completely free plates are considered in detail. The boundary value problem is essentially reduced to infinite systems of linear algebraic equations. New mathematical theory and associated results are presented for investigating the asymptotic behavior of non-trivial solution of quasi-regular infinite system. By enhancing the theory, an effective and accurate algorithm for determining the natural frequencies and modes shapes vibrations is developed. The accuracy and computational efficiency of the method are demonstrated by examples.

  18. Thermal and optical performance of encapsulation systems for flat-plate photovoltaic modules

    NASA Technical Reports Server (NTRS)

    Minning, C. P.; Coakley, J. F.; Perrygo, C. M.; Garcia, A., III; Cuddihy, E. F.

    1981-01-01

    The electrical power output from a photovoltaic module is strongly influenced by the thermal and optical characteristics of the module encapsulation system. Described are the methodology and computer model for performing fast and accurate thermal and optical evaluations of different encapsulation systems. The computer model is used to evaluate cell temperature, solar energy transmittance through the encapsulation system, and electric power output for operation in a terrestrial environment. Extensive results are presented for both superstrate-module and substrate-module design schemes which include different types of silicon cell materials, pottants, and antireflection coatings.

  19. Use of a Slick-Plate as a Contingency Exercise Surface for the Treadmill With Vibration Isolation System

    NASA Technical Reports Server (NTRS)

    Loehr, James A.; Lee, Stuart M. C.; Schneider, Suzanne M.

    2003-01-01

    The treadmill with vibration isolation system (TVIS) was developed to counteract cardiovascular, musculoskeletal, and neurovestibular deconditioning during long-duration missions to the International Space Station (ISS). However, recent hardware failures have necessitated the development of a short-term, temporary contingency exercise countermeasure for TVIS until nominal operations could be restored. The purpose of our evaluation was twofold: 1) to examine whether a slick-plate/contingency exercise surface (CES) could be used as a walking/running surface and could elicit a heart rate (HR) greater than or equal to 70% HR maximum and 2) to determine the optimal hardware configuration, in microgravity, to simulate running/walking in a 1-g environment. One subject (male) participated in the slick surface evaluation and two subjects (one male, one female) participated in the microgravity evaluation of the slick surface configuration. During the slick surface evaluation, the subject was suspended in a parachute harness and bungee cord configuration to offset the subject#s body weight. Using another bungee cord configuration, we added a vertical load back to the subject, who was then asked to run for 20 minutes on the slick surface. The microgravity evaluation simulated the ISS TVIS, and we evaluated two different slick surfaces (Teflon surface and an aluminum surface coated with Tufram) for use as a CES. We evaluated each surface with the subject walking and running, with and without a handrail, and while wearing either socks or nylon booties over shoes. In the slick surface evaluation, the subject ran for 20 minutes and reached a maximum HR of 170 bpm. In the microgravity evaluation, the subjects chose the aluminum plate coated with Tufram as the CES, while wearing a pair of nylon booties over running shoes and using a handrail, as the optimal hardware configuration.

  20. Multiple plate hydrostatic viscous damper

    SciTech Connect

    Ludwig, L.P.

    1981-02-01

    A device for damping radial motion of a rotating shaft is described. The damper comprises a series of spaced plates extending in a radial direction. A hydraulic piston is utilized to place a load in these plates. Each annular plate is provided with a suitable hydrostatic bearing geometry on at least one of its faces. This structure provides a high degree of dampening in a rotor case system of turbomachinery in general. The damper is particularly useful in gas turbine engines.

  1. Multiple plate hydrostatic viscous damper

    NASA Technical Reports Server (NTRS)

    Ludwig, L. P. (Inventor)

    1981-01-01

    A device for damping radial motion of a rotating shaft is described. The damper comprises a series of spaced plates extending in a radial direction. A hydraulic piston is utilized to place a load in these plates. Each annular plate is provided with a suitable hydrostatic bearing geometry on at least one of its faces. This structure provides a high degree of dampening in a rotor case system of turbomachinery in general. The damper is particularly useful in gas turbine engines.

  2. Structural-acoustic model of a rectangular plate-cavity system with an attached distributed mass and internal sound source: Theory and experiment

    NASA Astrophysics Data System (ADS)

    Pirnat, Miha; Čepon, Gregor; Boltežar, Miha

    2014-03-01

    In this paper three approaches are combined to develop a structural-acoustic model of a rectangular plate-cavity system with an attached distributed mass and internal sound source. The first approach results from a recently presented analysis based on the Rayleigh-Ritz method and is used to circumvent the difficulties in obtaining the natural frequencies and mode shapes of a plate with an attached, distributed mass. Furthermore, different plate boundary conditions can be accommodated. The resulting mode shapes are defined as continuous functions; this is advantageous as they can be directly used in the second approach, i.e., the classic modal-interaction approach in order to obtain the coupled equations of the system. Finally, in the third approach a group of point sources emitting a pressure pulse in the time domain is used to model an internal sound source. For the validation of the developed model an experiment was conducted in two configurations using a simply supported aluminium plate and a clamped plate coupled with a plexiglas box containing a loudspeaker. Good agreement was found between the analytical and experimental data.

  3. ELECTROMAGNETISM, OPTICS, ACOUSTICS, HEAT TRANSFER, CLASSICAL MECHANICS, AND FLUID DYNAMICS: On Feasibility of Variable Separation Method Based on Hamiltonian System for a Class of Plate Bending Equations

    NASA Astrophysics Data System (ADS)

    Eburilitu; Alatancang

    2010-03-01

    The eigenfunction system of infinite-dimensional Hamiltonian operators appearing in the bending problem of rectangular plate with two opposites simply supported is studied. At first, the completeness of the extended eigenfunction system in the sense of Cauchy's principal value is proved. Then the incompleteness of the extended eigenfunction system in general sense is proved. So the completeness of the symplectic orthogonal system of the infinite-dimensional Hamiltonian operator of this kind of plate bending equation is proved. At last the general solution of the infinite dimensional Hamiltonian system is equivalent to the solution function system series expansion, so it gives to theoretical basis of the methods of separation of variables based on Hamiltonian system for this kind of equations.

  4. Structure of different within-plate magmatic system of large igneous provinces

    NASA Astrophysics Data System (ADS)

    Sharkov, E.

    2009-04-01

    It is generally accepted that formation of continental large igneous provinces (LIPs) is linked with ascending of mantle superplumes. However, it is not clear yet why and how magmatic systems appeared and functionated. It is known that LIPs are formed by numerous magmatic centers, which imply existence of individual magmatic systems beneath them. Such a situation can be explained by presence of protuberances (local plumes) on the surface of extended superplume heads, where processes of adiabatic melting occurred give rise to formation of magmatic systems. Newly-formed melts on their way to the surface pass through complicate system of conduits and transitional magma chambers, where they were undergone by different processes of crystallizing differentiation, mixing, assimilation of wall-rocks, etc. According to data available, three major levels of transitional magmatic chambers, linked by systems of feeder conduits (dikes), occurred within the crust. Each of them is responsible for transformation of a primary melt in different extent: The lowest level with the largest chambers, located along boundary between upper margin of the plume head and incumbent rigid lithosphere; they are responsible for the underplating phenomenon. Processes of contamination mantle-derived magmas by crustal material can play essential role here, especially in the late Archean and early Paleoproterozoic when they led to appearance of specific mantle-crustal magmas of siliceous high-Mg series (SHMS), which formed large igneous provinces with numerous mafic-iltramafic layered intrusions (Sharkov, Bogina, 2006). It suggests that formation of this series was linked with "floating up" of chambers (batches) of high-temperature ultramafic magmas through the upper part of lithospheric mantle and mafic lower crust by zone refinement mechanism, i.e. by melting material of the chamber's roof and crystallization at their bottoms. As a result, the primary melt gradually enriched in crustal material

  5. A fluid–structure interaction model to characterize bone cell stimulation in parallel-plate flow chamber systems

    PubMed Central

    Vaughan, T. J.; Haugh, M. G.; McNamara, L. M.

    2013-01-01

    Bone continuously adapts its internal structure to accommodate the functional demands of its mechanical environment and strain-induced flow of interstitial fluid is believed to be the primary mediator of mechanical stimuli to bone cells in vivo. In vitro investigations have shown that bone cells produce important biochemical signals in response to fluid flow applied using parallel-plate flow chamber (PPFC) systems. However, the exact mechanical stimulus experienced by the cells within these systems remains unclear. To fully understand this behaviour represents a most challenging multi-physics problem involving the interaction between deformable cellular structures and adjacent fluid flows. In this study, we use a fluid–structure interaction computational approach to investigate the nature of the mechanical stimulus being applied to a single osteoblast cell under fluid flow within a PPFC system. The analysis decouples the contribution of pressure and shear stress on cellular deformation and for the first time highlights that cell strain under flow is dominated by the pressure in the PPFC system rather than the applied shear stress. Furthermore, it was found that strains imparted on the cell membrane were relatively low whereas significant strain amplification occurred at the cell–substrate interface. These results suggest that strain transfer through focal attachments at the base of the cell are the primary mediators of mechanical signals to the cell under flow in a PPFC system. Such information is vital in order to correctly interpret biological responses of bone cells under in vitro stimulation and elucidate the mechanisms associated with mechanotransduction in vivo. PMID:23365189

  6. Cadmium plating replacements

    SciTech Connect

    Nelson, M.J.; Groshart, E.C.

    1995-03-01

    The Boeing Company has been searching for replacements to cadmium plate. Two alloy plating systems seem close to meeting the needs of a cadmium replacement. The two alloys, zinc-nickel and tin-zinc are from alloy plating baths; both baths are neutral pH. The alloys meet the requirements for salt fog corrosion resistance, and both alloys excel as a paint base. Currently, tests are being performed on standard fasteners to compare zinc-nickel and tin-zinc on threaded hardware where cadmium is heavily used. The Hydrogen embrittlement propensity of the zinc-nickel bath has been tested, and just beginning for the tin-zinc bath. Another area of interest is the electrical properties on aluminum for tin-zinc and will be discussed. The zinc-nickel alloy plating bath is in production in Boeing Commercial Airplane Group for non-critical low strength steels. The outlook is promising that these two coatings will help The Boeing Company significantly reduce its dependence on cadmium plating.

  7. Cadmium plating replacements

    NASA Technical Reports Server (NTRS)

    Nelson, Mary J.; Groshart, Earl C.

    1995-01-01

    The Boeing Company has been searching for replacements to cadmium plate. Two alloy plating systems seem close to meeting the needs of a cadmium replacement. The two alloys, zinc-nickel and tin-zinc are from alloy plating baths; both baths are neutral pH. The alloys meet the requirements for salt fog corrosion resistance, and both alloys excel as a paint base. Currently, tests are being performed on standard fasteners to compare zinc-nickel and tin-zinc on threaded hardware where cadmium is heavily used. The Hydrogen embrittlement propensity of the zinc-nickel bath has been tested, and just beginning for the tin-zinc bath. Another area of interest is the electrical properties on aluminum for tin-zinc and will be discussed. The zinc-nickel alloy plating bath is in production in Boeing Commercial Airplane Group for non-critical low strength steels. The outlook is promising that these two coatings will help The Boeing Company significantly reduce its dependence on cadmium plating.

  8. Imaging at soft X-ray wavelengths with high-gain microchannel plate detector systems

    NASA Technical Reports Server (NTRS)

    Timothy, J. Gethyn

    1986-01-01

    Multianode microchannel array (MAMA) detector systems with formats of 256 x 1024 pixels and active areas of 6 x 26 mm are now under evaluation at visible, UV and soft X-ray wavelengths. Very-large-format versions of the MAMA detectors with formats of 2048 x 2048 pixels and active areas of 52 x 52 mm are under development for use in the NASA Goddard Space Telescope Imaging Spectrograph (STIS). Open-structure versions of these detectors with Cs I photocathodes can provide a high-resolution imaging capability at EUV and soft X-ray wavelengths and can deliver a maximum count rate from each array in excess of 10 to the 6th counts/s. In addition, these detector systems have the unique capability to determine the arrival time of a detected photon to an accuracy of 100 ns or better. The construction, mode of operation, and performance characteristics of the MAMA detectors are described, and the program for the development of the very-large-format detectors is outlined.

  9. Degradative and mechanical properties of a novel resorbable plating system during a 3-year follow-up in vivo and in vitro.

    PubMed

    Nieminen, Tuomo; Rantala, Immo; Hiidenheimo, Ilmari; Keränen, Jaakko; Kainulainen, Heikki; Wuolijoki, Erkki; Kallela, Ilkka

    2008-03-01

    We tested the tissue reactions and mechanical strength of a novel biodegradable craniomaxillofacial plating system, Inion CPS, in the course of degradation. Plates and screws composed of L-lactide, D-lactide and trimethylene carbonate were implanted to the mandible and dorsal subcutis of 12 sheep. The animals were sacrificed at 6-156 weeks. Histological evaluation was done using paraffin and methylmetacrylate techniques. Degradative and mechanical properties during the follow-up were measured both of in vivo and in vitro implants. In light microscopy, the in vivo implant material began to fragment at 52 weeks and could not be detected at 104 weeks. No significant foreign body reactions were seen in the mandibles. The dorsal subcutis disclosed mild reactions, which were, however, not of clinical significance. The implants in vitro maintained their entire mass for 26 weeks and lost 63-80% of the mass by week 104. The inherent viscosity of the implants in vitro and in vivo diminished uniformly. The screws retained their shear strength for 12-16 weeks. The plates maintained their tensile strength for at least 6 weeks. The maximum capacity of the plates in 3-point bending tests diminished gradually by 87% in 26 weeks. In conclusion, the plates and screws examined maintain adequate strength for the healing period of a bone fracture or osteotomy, producing no harmful foreign body reactions. PMID:17701310

  10. Characterization of deformation perpendicular to relative plate motion and major faults of the northern San Andreas system using geodetic data

    NASA Astrophysics Data System (ADS)

    Murray, J. R.; Pollitz, F. F.

    2014-12-01

    The northern San Andreas fault system NW of Clear Lake, CA is comprised of the subparallel San Andreas, Maacama, and Bartlett Springs faults. The dominant geodetic signal across the region is right lateral shear strain largely accommodated by infrequent earthquakes on these three faults and creep on the upper 5 km of the latter two. Here we use a newly densified Global Positioning System (GPS) velocity field (Murray et al., 2014) to assess the existence of regional contraction/extension. If present, the degree to which this deformation contributes to oblique slip in future earthquakes or, conversely, is partitioned into off-fault strain has implications for anticipated ground motions and inferred on-fault and off-fault moment deficit rates used in seismic hazard assessment. We inspect the observed horizontal GPS velocity field in a Sierra Nevada-Great Valley (SNGV) fixed frame. To first order the maximum contractile strain rate axis is well-aligned with the maximum compressive stress orientation (Provost and Houston, 2003). Although observed velocities at coastal sites compared to those on the SNGV block show little net strain perpendicular to the direction of Pacific-SNGV relative motion, velocity profiles transecting the three faults show both contraction and extension perpendicular to relative plate motion within the zone between the Great Valley and the coast. To evaluate this signal in the context of fault slip, we consider the residual fault-perpendicular velocity after removing predicted velocities due to the strike-slip component of estimated creep and interseismic locking (Murray et al., 2014). The slip rate model accounts for the fact that the orientations of the three major faults vary along their lengths, the faults are neither uniformly parallel to each other nor to the relative plate motion direction, and strike-slip creep rates vary along strike. In many locations near-fault residual strain rates are small, suggesting geometry and non-uniform creep

  11. Micro-channel plate detector

    DOEpatents

    Elam, Jeffrey W.; Lee, Seon W.; Wang, Hsien -Hau; Pellin, Michael J.; Byrum, Karen; Frisch, Henry J.

    2015-09-22

    A method and system for providing a micro-channel plate detector. An anodized aluminum oxide membrane is provided and includes a plurality of nanopores which have an Al coating and a thin layer of an emissive oxide material responsive to incident radiation, thereby providing a plurality of radiation sensitive channels for the micro-channel plate detector.

  12. Two-dimensional laser servoing for precision motion control of an ODV robotic license plate recognition system

    NASA Astrophysics Data System (ADS)

    Song, Zhen; Moore, Kevin L.; Chen, YangQuan; Bahl, Vikas

    2003-09-01

    As an outgrowth of series of projects focused on mobility of unmanned ground vehicles (UGV), an omni-directional (ODV), multi-robot, autonomous mobile parking security system has been developed. The system has two types of robots: the low-profile Omni-Directional Inspection System (ODIS), which can be used for under-vehicle inspections, and the mid-sized T4 robot, which serves as a ``marsupial mothership'' for the ODIS vehicles and performs coarse resolution inspection. A key task for the T4 robot is license plate recognition (LPR). For a successful LPR task without compromising the recognition rate, the robot must be able to identify the bumper locations of vehicles in the parking area and then precisely position the LPR camera relative to the bumper. This paper describes a 2D-laser scanner based approach to bumper identification and laser servoing for the T4 robot. The system uses a gimbal-mounted scanning laser. As the T4 robot travels down a row of parking stalls, data is collected from the laser every 100ms. For each parking stall in the range of the laser during the scan, the data is matched to a ``bumper box'' corresponding to where a car bumper is expected, resulting in a point cloud of data corresponding to a vehicle bumper for each stall. Next, recursive line-fitting algorithms are used to determine a line for the data in each stall's ``bumper box.'' The fitting technique uses Hough based transforms, which are robust against segmentation problems and fast enough for real-time line fitting. Once a bumper line is fitted with an acceptable confidence, the bumper location is passed to the T4 motion controller, which moves to position the LPR camera properly relative to the bumper. The paper includes examples and results that show the effectiveness of the technique, including its ability to work in real-time.

  13. Chest wall stabilization and reconstruction: short and long-term results 5 years after the introduction of a new titanium plates system

    PubMed Central

    Sollitto, Francesco; Loizzi, Domenico; Di Gennaro, Francesco; Scarascia, Daniele; Carlucci, Annalisa; Giudice, Giuseppe; Armenio, Andrea; Ludovico, Rossana; Loizzi, Michele

    2016-01-01

    Background We report short and long-term results with the dedicated Synthes® titanium plates system, introduced 5 years ago, for chest wall stabilization and reconstruction. Methods We retrospectively analyzed (January 2010 to December 2014) 27 consecutive patients (22 males, 5 females; range 16–83 years, median age 60 years), treated with this system: primary [3] and secondary [8] chest wall tumor; flail chest [5]; multiple ribs fractures [5]; sternal dehiscence-diastasis [3]; sternal fracture [1]; sternoclavicular joint dislocation [1]; Poland syndrome [1]. Short-term results were evaluated as: operating time, post-operative morbidity, mortality, hospital stay; long-term results as: survival, plates-related morbidity, spirometric values, chest pain [measured with Verbal Rating Scale (VRS) and SF12 standard V1 questionnaire]. Results Each patient received from 1 to 10 (median 2) titanium plates/splints; median operating time was 150 min (range: 115–430 min). Post-operative course: 15 patients (55.6%) uneventful, 10 (37%) minor complications, 2 (7.4%) major complications; no post-operative mortality. Median post-operative hospital stay was 13 days (range: 5–129 days). At a median follow-up of 20 months (range: 1–59 months), 21 patients (78%) were alive, 6 (22%) died. Three patients presented long-term plates-related morbidity: plates rupture [2], pin plate dislodgment [1]; two required a second surgical look. One-year from surgery median spirometric values were: FVC 3.31 L (90%), FEV1 2.46 L (78%), DLCO 20.9 mL/mmHg/min (76%). On 21 alive patients, 7 (33.3%) reported no pain (VRS score 0), 10 (47.6%) mild (score 2), 4 (19.1%) moderate (score 4), no-one severe (score >4); 15 (71.5%) reported none or mild, 6 (28.5%) moderate pain influencing quality of life. Conclusions An optimal chest wall stabilization and reconstruction was achieved with the Synthes® titanium plates system, with minimal morbidity, no post-operative mortality, acceptable operating time

  14. An Affordable, Indigenous Polarizer-Analyser System with Inbuilt Retardation Plate Function to Detect Birefringence using 3D Glasses: An Experience

    PubMed Central

    Sudhir, Dange Prasad; Saksena, Annapurna; Khurana, Nita

    2016-01-01

    Introduction Polarizing microscope plays a vital role in few but unique situations. A pair of cross polarizers is used to confirm the presence of birefringent substances. Also, a red retardation plate is needed to evaluate the sign of birefringence. However, a polarizing microscope especially with retardation plate is very expensive. Thus, an affordable yet effective substitute using the 3D Polaroid glasses used for ‘3D movies’ would enable widespread use of the polarizing system. Aim To study the use of 3D polaroid glasses procured from cinema halls in detecting birefringence substances and to study the red retardation plate function in them. Materials and Methods Passive 3D Polaroid glasses were procured from cinema halls. They were arranged in aspecific manner to obtain polarized light. Red retardation plate function can be obtained by changing the arrangement of the glasses. These glasses were used with various available models of different light microscope manufacturers. Various specimens observed included amyloid deposits, woven and lamellar bone, skeletal muscle striations, urate crystals, cholesterol crystals, suture material and glove powder. The comparison was based on subjective interpretation of intensity and quality of birefringence. Sign of birefringence was also determined whenever relevant. Results The birefringence observed by our system was comparable to the commercially available polarizing system with respect to intensity and quality. Also, there were no false positive /negative results when compared with the commercial Polarizing microscope. Moreover, the system had an inbuilt red retardation plate to determine sign of birefringence. Conclusion The system is efficient, cheap, easily accessible, portable and compatible with all models of light microscopes. PMID:26894072

  15. Accuracy of scanography using storage phosphor plate systems and film for assessment of mandibular third molars

    PubMed Central

    Matzen, LH; Christensen, J; Wenzel, A

    2011-01-01

    Objectives The aim of this study was to compare the diagnostic accuracy of two digital photostimulable storage phosphor (PSP) systems and film for assessment of mandibular third molars before surgery. Methods 110 patients were referred to have both their mandibular third molars removed. Each patient underwent a radiographic examination with scanography using either Digora (Soredex, Helsinki, Finland) and film or VistaScan (Dürr Dental, Beitigheim-Bissingen, Germany) and film in a randomized paired design. Two observers examined the following variables on the scanograms: bone coverage, angulation of the tooth in the bone, number of roots, root morphology and the relationship to the mandibular canal. In 75 of the pairs (Digora/film pair = 38 and Vista/film pair = 37) both third molars were eventually removed. During and after surgery the same variables were assessed, which served as reference standard for the radiographic assessments. The Wilcoxon signed-rank test tested differences in accuracy (radiographic compared with surgical findings) between Digora/film and between Vista/film. Results There was no statistically significant difference between the diagnostic accuracy of film and either of the two digital receptors for assessment of mandibular third molars before surgery (P > 0.05), although Digora obtained a higher accuracy than film. Conclusions Scanography is a valuable method for examination of mandibular third molars before removal and the PSP digital receptors in this study were equal to film for this purpose. PMID:21697156

  16. Multiplexed chemiluminescent assays in ArrayPlates for high-throughput measurement of gene expression

    NASA Astrophysics Data System (ADS)

    Martel, Ralph R.; Rounseville, Matthew P.; Botros, Ihab W.; Seligmann, Bruce E.

    2002-06-01

    Multiplexed Molecular Profiling (MMP) assays for drug discovery are performed in ArrayPlates. ArrayPlates are 96- well microtiter plates that contain a 16-element array at the bottom of each well. Each element within an array measures one analyte in a sample. A CCD imager records the quantitative chemiluminescent readout of all 1,536 elements in a 96-well plate simultaneously. Since array elements are reagent modifiable by the end-user, ArrayPlates can be adapted to a broad range of nucleic acid- and protein-based assays. Such multiplexed assays are rapidly established, flexible, robust, automation-friendly and cost-effective. Nucleic acid assays in ArrayPlates can detect DNA and RNA, including SNPs and ESTs. A multiplexed mRNA assay to measure the expression of 16 genes is described. The assay combines a homogeneous nuclease protection assay with subsequent probe immobilization to the array by means of a sandwich hybridization followed with chemiluminescent detection. This assay was used to examine cells grown and treated in microplates and avoided cloning, transfection, RNA insolation, reverse transcription, amplification and fluorochrome labeling. Standard deviations for the measurement of 16 genes ranged from 3 percent to 13 percent in samples of 30,000 cells. Such ArrayPlates transcription assays are useful in drug discovery and development for target validation, screening, lead optimization, metabolism and toxicity profiling. Chemiluminescent detection provides ArrayPlates assays with high signal-to-noise readout and simplifies imager requirements. Imaging a 2D surface that contains arrays simplifies lens requirements relative to imaging columns of liquid in microtiter plate wells. The Omix imager for ArrayPlates is described.

  17. Deposition and survival of Escherichia coli O157:H7 on clay minerals in a parallel plate flow system.

    PubMed

    Cai, Peng; Huang, Qiaoyun; Walker, Sharon L

    2013-02-19

    Understanding bacterial pathogens deposition and survival processes in the soil-groundwater system is crucial to protect public health from soilborne and waterborne diseases. However, mechanisms of bacterial pathogen-clay interactions are not well studied, particularly in dynamic systems. Also, little is known about the viability of bacterial pathogens when attached to clays. In this study, a parallel plate flow system was used to determine the deposition kinetics and survival of Escherichia coli O157:H7 on montmorillonite, kaolinite, and goethite over a wide range of ionic strengths (IS) (0.1-100 mM KCl). E. coli O157:H7 deposition on the positively charged goethite is greater than that on the negatively charged kaolinite and montmorillonite. Although the zeta potential of kaolinite was more negative than that of montmorillonite, kaolinite showed a greater deposition for E. coli O157:H7 than montmorillonite, which is attributed to the chemical heterogeneity of clay minerals. Overall, increasing IS resulted in an increase of E. coli O157:H7 deposition on montmorillonite and kaolinite, and a decrease on goethite. Interaction energy calculations suggest that E. coli O157:H7 deposition on clays was largely governed by DLVO (Derjaguin-Landau-Verwey-Overbeek) forces. The loss of bacterial membrane integrity was investigated as a function of time using the Live/Dead BacLight viability assay. During the examined period of 6 h, E. coli O157:H7 retained its viability in suspension and when attached to montmorillonite and kaolinite; however, interaction with the goethite was detrimental. The information obtained in this study is of fundamental significance for the understanding of the fate of bacterial pathogens in soil environments. PMID:23346967

  18. MHD Two-Fluid Flow and Heat Transfer between Two Inclined Parallel Plates in a Rotating System

    PubMed Central

    Sri Ramachandra Murty, P.; Balaji Prakash, G.

    2014-01-01

    Two-phase magnetohydrodynamic convective flow of electrically conducting fluid through an inclined channel is studied under the action of a constant transverse magnetic field in a rotating system. The fluids in the two phases are steady, incompressible, laminar, immiscible, and electrically conducting, having different densities, viscosities, and thermal and electrical conductivities. The transport properties of both the fluids are assumed constant. The bounding infinite inclined parallel plates are maintained at different constant temperatures, making an angle ϕ with the horizontal. Approximate solutions for velocity and temperature distributions are obtained by using a straightforward regular perturbation technique. An in-depth study has been done on the effects of rotation parameter, Hartmann number, inclination angle, the ratio of electrical conductivities, and viscosities of two fluids on the flow. It is observed that the effect of increasing rotation is to decrease the primary velocity. Further it is noticed that as the rotation increases, the secondary velocity increases for smaller rotation, while for larger rotation it decreases. It is also found that the temperature distribution decreases as the rotation increases. PMID:27351017

  19. Detection system for inclusion defects in hot-rolled steel plates using MFLT with two different magnetizing strengths

    NASA Astrophysics Data System (ADS)

    Yotsuji, Junichi; Koshihara, Takahiro

    2014-02-01

    Recently, steel can manufacturing requires higher quality because otherwise minute non-metallic inclusions in thin sheets cause cracks and result in a burst during pressurization after the pressing process. Quality testing systems have already been installed in the final process in steel plants, but if there were another inspection in an earlier step, for example, at the hot strip mill, the mass manufacture of nonconforming products could be avoided and maintaining quality control would be more efficient. In order to detect inclusion defects in hot-rolled steel plates, the authors developed a new technique for MFLT (Magnetic Flux Leakage Testing) using different magnetizing forces. According to an analysis of the noise factors in MFLT, it was found that the signals generated from the scale layer on a steel surface are dominant. A different magnetizing force method is the used to decrease this overpowering noise level in MFLT. In this paper, it was confirmed that inclusions larger than 160μm in diameter and less than 0.45mm in depth can be detected utilizing this method.

  20. The Formation of the Betic-Alboran System in the Iberia-Africa Plate Boundary: a New Kinematic Evolution Model

    NASA Astrophysics Data System (ADS)

    Fernandez, M.; Verges, J.

    2013-12-01

    Several geodynamic models have been proposed so far to explain the origin and evolution of the Betic-Rif arcuate orogeny and the inner Alboran back-arc basin. Many of these models propose that the Alboran domain underwent a large westward drifting (> 600 km) driven by a subduction rollback, eventually resulting in a symmetric configuration in both the S-Iberia and N-African margins. Alternative models with a more autochthonous component assume that the Oligocene subduction trench extended continuously along the whole Iberian Mediterranean margin from the present Gibraltar arc to the Alps. Common assumptions to all these models are: i) the initial time is about 35 Ma (Eocene-Oligocene), ii) the plate boundary is continuous and non-segmented, iii) the initial subduction polarity is NW-dipping, and iv) the slab must underwent a twisted roll-back to explain the present position of the HP-LT metamorphic rocks involving slab rupture, detachment and tearing. Recent geophysical models based on seismic data, tomography and potential fields draw an arcuate mantle slab restricted below the Betic-Rif orogen, dipping towards the E below the Gibraltar Strait and turning to the SE and S beneath the Betics. In addition, the crust beneath the northern Moroccan margin shows a smooth thinning toward the Alboran basin whereas the southern Iberian margin presents a much sharper thinning. These findings put severe limitations to some of the proposed models and open room for new kinematic proposals. One of the most recent models is based on the following considerations: i) the reconstruction starts in Late Cretaceous times at the onset of northern Africa convergence, ii) displacements and initial configuration are based on plate reconstructions of the Atlantic-Ligurian-Tethys region, and iii) the model assumes that subduction polarity changes laterally from NW-dipping in the Algerian segment to SE-dipping in the Betic-Rif segment. Apart from its simplicity, this model requires a moderate

  1. Improved Thermal-Vacuum Compatible Flat Plate Radiometric Souce for System-Level Testing of Optical Sensors

    NASA Technical Reports Server (NTRS)

    Schwarz, Mark A.; Kent, Craig J.; Bousquet, Robert; Brown, Steven W.

    2015-01-01

    This work describes the development of an improved vacuum compatible flat plate radiometric source used for characterizing and calibrating remote optical sensors, in situ, throughout their testing period. The original flat plate radiometric source was developed for use by the VIIRS instrument during the NPOESS Preparatory Project (NPP). Following this effort, the FPI has had significant upgrades in order to improve both the radiometric throughput and uniformity. Results of the VIIRS testing with the reconfigured FPI are reported and discussed.

  2. Near Fault Observatories (NFO) services and integration plan for European Plate Observing System (EPOS) Implementation Phase

    NASA Astrophysics Data System (ADS)

    Chiaraluce, Lauro

    2016-04-01

    the services provided by other Thematic Core Services for the standard data (e.g. seismic and geodetic) and on the direct access to the e-infrastructures of individual NFOs via the Integrated Core Services web services for access and distribution of non standard data (e.g. strain- and tilt-meters, geochemical and electro- magneto-telluric data). We will collaborate with the other groups possessing the same data on data harmonization in terms of both format and metadata description to optimise and facilitate the integration and interoperability processes. The services will include a Virtual Laboratory, novel visualization tools for data and products describing the anatomy of active faults and the physical processes governing earthquake generation. VL is an online engagement and knowledge sharing initiative for communicating to the other scientists, stockholders and the public the state of scientific knowledge concerning earthquake source and tectonic processes generating catastrophic events. The availability of real-time data provides the unique opportunity of observing all phases of the earthquake rupture. It is thus of crucial importance developing methodologies to follow in real-time the evolution of the event (e.g. Earthquake Early Warning systems). NFOs are ideal infrastructures for hosting testing centers where a variety of scientific algorithms for real-time monitoring can be independently evaluated. Besides the interest for fundamental science, such developments have a societal impact and can attract new stakeholders such as industry partners who are interested in adopting in such (e.g. EEW) technologies.

  3. The European Plate Observing System (EPOS): Integrating Thematic Services for Solid Earth Science

    NASA Astrophysics Data System (ADS)

    Atakan, Kuvvet; Bailo, Daniele; Consortium, Epos

    2016-04-01

    The mission of EPOS is to monitor and understand the dynamic and complex Earth system by relying on new e-science opportunities and integrating diverse and advanced Research Infrastructures in Europe for solid Earth Science. EPOS will enable innovative multidisciplinary research for a better understanding of the Earth's physical and chemical processes that control earthquakes, volcanic eruptions, ground instability and tsunami as well as the processes driving tectonics and Earth's surface dynamics. Through integration of data, models and facilities EPOS will allow the Earth Science community to make a step change in developing new concepts and tools for key answers to scientific and socio-economic questions concerning geo-hazards and geo-resources as well as Earth sciences applications to the environment and to human welfare. EPOS, during its Implementation Phase (EPOS-IP), will integrate multidisciplinary data into a single e-infrastructure. Multidisciplinary data are organized and governed by the Thematic Core Services (TCS) and are driven by various scientific communities encompassing a wide spectrum of Earth science disciplines. These include Data, Data-products, Services and Software (DDSS), from seismology, near fault observatories, geodetic observations, volcano observations, satellite observations, geomagnetic observations, as well as data from various anthropogenic hazard episodes, geological information and modelling. In addition, transnational access to multi-scale laboratories and geo-energy test-beds for low-carbon energy will be provided. TCS DDSS will be integrated into Integrated Core Services (ICS), a platform that will ensure their interoperability and access to these services by the scientific community as well as other users within the society. This requires dedicated tasks for interactions with the various TCS-WPs, as well as the various distributed ICS (ICS-Ds), such as High Performance Computing (HPC) facilities, large scale data storage

  4. Assay of creatine kinase in microtiter plates using thio-NAD to allow monitoring at 405 nM.

    PubMed

    Florini, J R

    1989-11-01

    An assay system for creatine kinase using microtiter plates and a plate reader that records absorbancies at 405 nM has been devised. The system is an adaptation of well-established assays that couple creatine kinase with the reactions catalyzed by hexokinase and glucose-6-phosphate dehydrogenase (G6PDH), to give a measurable increase in reduced pyridine nucleotide quantitated by absorbance at 340 nM. Two features of this system are modified for reading at 405 nM: (i) The thioamido derivative of NAD is used because its reduced form exhibits a substantial increase in absorbance at 405 nM, the most commonly available wavelength on microplate readers; and (ii) glucose-6-phosphate dehydrogenase from Leuconostoc mesenteroides is used because it can reduce either NAD or NADP (unlike most other G6PDH enzymes, which require NADP), thus making it unnecessary to use the more expensive thio-NADP. The rate of thio-NAD reduction is linear with enzyme concentration and time over a 20-fold range of concentrations of purified creatine kinase, and the assay also works well with myogenic cells allowed to grow and differentiate in the 96-well plate in which the assay is performed. This system offers considerable savings in cells, time, and material in studies of muscle cell differentiation, for which creatine kinase levels are frequently measured. It also provides a potential method for the convenient and economical measurement of activities of many other enzymes that can be coupled to reduction of thio-NAD. PMID:2610356

  5. A novel integration system of magnetically immobilized cells and a pair of graphite plate-stainless iron mesh electrodes for the bioremediation of coking wastewater.

    PubMed

    Jiang, Bei; Tan, Liang; Ning, Shuxiang; Shi, Shengnan

    2016-09-01

    Magnetically immobilized cells of Comamonas sp. JB coupling with electrode reaction was developed to enhance the treatment efficiency of coking wastewater containing phenol, carbazole (CA), dibenzofuran (DBF), and dibenzothiophene (DBT). The pair of graphite plate-stainless iron mesh electrodes was chosen as the most suitable electrodes. Magnetically immobilized cells coupling with graphite plate-stainless iron mesh electrodes (coupling system) exhibited high degradation activity for all the compounds, which were significantly higher than the sum by single magnetically immobilized cells and electrode reaction at the optimal voltage. Recycling experiments demonstrated that the degradation activity of coupling system increased gradually during eight recycles, indicating that there was a coupling effect between the biodegradation and electrode reaction. Phenol hydroxylase and qPCR assays confirmed that appropriate electrical stimulation could improve phenol hydroxylase activity and promote cells growth. Toxicity assessment suggested the treatment of the coking wastewater by coupling system led to less toxicity than untreated wastewater. PMID:27289060

  6. Comparison of diploid fibroblast and rabbit kidney tissue cultures and a diploid fibroblast microtiter plate system for the isolation of herpes simplex virus.

    PubMed Central

    Langenberg, A; Zbanyszek, R; Dragavon, J; Ashley, R; Corey, L

    1988-01-01

    We evaluated the relative sensitivities of two cell systems (rabbit kidney [RK] and human diploid fibroblast [DF; human embryonic tonsil]) in standard tube cultures versus DF cells in a 48-well microtiter plate system for the detection of both symptomatic and asymptomatic herpes simplex virus (HSV) infection. At least one system isolated HSV in 111 of 809 specimens (13.7%). HSV was isolated in RK tube cultures from 110 specimens (99%), in DF tube cultures from 91 specimens (82%), and in DF microtiter plates from 95 specimens (86%). The frequency of HSV isolation varied with the anatomic site and the presence or absence of a herpetic lesion. The sensitivities of the three culture systems remained similar whether the specimens were obtained from lesions or whether the specimens were taken to determine if asymptomatic excretion of HSV was present. While RK tube cultures were more sensitive than DF tube cultures, the DF microtiter plate system was as sensitive as DF tube cultures and its use is supported as a cheaper and less labor-intensive method for the detection of HSV. PMID:2846647

  7. Impact on plate waste of switching from a tray to a trayless delivery system in a university dining hall and employee response to the switch.

    PubMed

    Thiagarajah, Krisha; Getty, Victoria M

    2013-01-01

    A potential strategy for decreasing food waste in foodservice operations is trayless dining. The objective of this 2010 study was to compare the impact of using a tray vs a trayless system on plate waste and on employees' attitudes. To test the hypothesis that going trayless would reduce waste, liquid and solid plate waste were measured for 1 week with the then-existing tray system and again after a new trayless system was implemented in a buffet-style university dining hall serving roughly1,000 meals a day. Foodservice staff were invited to participate in a focus group about the impact on their jobs. The investigators calculated plate waste per patron under the two systems and used an independent samples t test to examine the significance of the difference. Comments from the focus group were analyzed for themes. A significant decrease in solid waste per patron (0.81 oz; P=0.001) was observed in switching from the tray to the trayless system (4.39 ± 0.24 oz vs 3.58 ± 0.08 oz per patron). A nonsignificant reduction was observed with liquid waste (49.77 ± 2.62 mL vs 46.36 ± 4.51 mL; P=0.18). Most of the employees preferred the trayless system as long as it did reduce waste, but felt that increased breakage of dishware and increased need to wipe down tables were possible concerns resulting from the switch. This study demonstrates that trayless dining can reduce plate waste, and that employees can be supportive of the change. PMID:23088899

  8. Large-scale right-slip displacement on the East San Francisco Bay Region fault system, California: Implications for location of late Miocene to Pliocene Pacific plate boundary

    USGS Publications Warehouse

    McLaughlin, R.J.; Sliter, W.V.; Sorg, D.H.; Russell, P.C.; Sarna-Wojcicki, A. M.

    1996-01-01

    A belt of northwardly younging Neogene and Quaternary volcanic rocks and hydrothermal vein systems, together with a distinctive Cretaceous terrane of the Franciscan Complex (the Permanente terrane), exhibits about 160 to 170 km of cumulative dextral offset across faults of the East San Francisco Bay Region (ESFBR) fault system. The offset hydrothermal veins and volcanic rocks range in age from .01 Ma at the northwest end to about 17.6 Ma at the southeast end. In the fault block between the San Andreas and ESFBR fault systems, where volcanic rocks are scarce, hydrothermal vein system ages clearly indicate that the northward younging thermal overprint affected these rocks beginning about 18 Ma. The age progression of these volcanic rocks and hydrothermal vein systems is consistent with previously proposed models that relate northward propagation of the San Andreas transform to the opening of an asthenospheric window beneath the North American plate margin in the wake of subducting lithosphere. The similarity in the amount of offset of the Permanente terrane across the ESFBR fault system to that derived by restoring continuity in the northward younging age progression of volcanic rocks and hydrothermal veins suggests a model in which 80-110 km of offset are taken up 8 to 6 Ma on a fault aligned with the Bloomfield-Tolay-Franklin-Concord-Sunol-Calaveras faults. An additional 50-70 km of cumulative slip are taken up ??? 6 Ma by the Rogers Creek-Hayward and Concord-Franklin-Sunol-Calaveras faults. An alternative model in which the Permanente terrane is offset about 80 km by pre-Miocene faults does not adequately restore the distribution of 8-12 Ma volcanic rocks and hydrothermal veins to a single northwardly younging age trend. If 80-110 km of slip was taken up by the ESFBR fault system between 8 and 6 Ma, dextral slip rates were 40-55 mm/yr. Such high rates might occur if the ESFBR fault system rather than the San Andreas fault acted as the transform margin at this time

  9. SAMI Automated Plug Plate Configuration

    NASA Astrophysics Data System (ADS)

    Lorente, N. P. F.; Farrell, T.; Goodwin, M.

    2013-10-01

    The Sydney-AAO Multi-object Integral field spectrograph (SAMI) is a prototype wide-field system at the Anglo-Australian Telescope (AAT) which uses a plug-plate to mount its 13×61-core imaging fibre bundles (hexabundles) in the optical path at the telescope's prime focus. In this paper we describe the process of determining the positions of the plug-plate holes, where plates contain three or more stacked observation configurations. The process, which up until now has involved several separate processes and has required significant manual configuration and checking, is now being automated to increase efficiency and reduce error. This is carried out by means of a thin Java controller layer which drives the configuration cycle. This layer controls the user interface and the C++ algorithm layer where the plate configuration and optimisation is carried out. Additionally, through the Aladin display package, it provides visualisation and facilitates user verification of the resulting plates.

  10. Improved Thermal-Vacuum Compatible Flat Plate Radiometric Source For System-Level Testing Of Optical Sensors

    NASA Technical Reports Server (NTRS)

    Schwarz, Mark A.; Kent, Craig J.; Bousquet, Robert; Brown, Steven W.

    2016-01-01

    In this work, we describe an improved thermal-vacuum compatible flat plate radiometric source which has been developed and utilized for the characterization and calibration of remote optical sensors. This source is unique in that it can be used in situ, in both ambient and thermal-vacuum environments, allowing it to follow the sensor throughout its testing cycle. The performance of the original flat plate radiometric source was presented at the 2009 SPIE1. Following the original efforts, design upgrades were incorporated into the source to improve both radiometric throughput and uniformity. The pre-thermal-vacuum (pre-TVAC) testing results of a spacecraft-level optical sensor with the improved flat plate illumination source, both in ambient and vacuum environments, are presented. We also briefly discuss potential FPI configuration changes in order to improve its radiometric performance.

  11. The effect of aluminium on the formation of orthorhombic plates in the Nb-Ti-Al ternary system

    SciTech Connect

    Hoelzer, D.T.; Ebrahimi, F.

    1997-12-31

    Transmission electron microscopy (TEM) was used to study the phase transformation in an alloy containing 33Ti-27Nb-40Al (at.%). The results showed that the BCC {beta} phase was present at high temperatures, which ordered to the B 2 phase, and finally was martensitically transformed to a plate microstructure during quenching. The plates possessed an orthorhombic crystal structure and a substructure that consisted of both coarse and fine anti-phase domain boundaries (APDBs). These APDBs were consistent with three sublattices that were derived from the inherited site occupancy of the B2 matrix and a subsequent disorder to order transition. The CBED analysis of the plates showed that the site occupancy of this orthorhombic phase was consistent with the Al{sub 2}NbTi stoichiometry with Al occupying the 8g, Nb the 4cl, and Ti the 4c2 Wyckoff sites.

  12. Plating versus intramedullary fixation for mid-shaft clavicle fractures: a systemic review and meta-analysis

    PubMed Central

    Gao, Yan; Chen, Wei; Liu, Yue-Jv; Li, Xu; Wang, Hai-Li

    2016-01-01

    Background. Plate fixation and intramedullary fixation are the most commonly used surgical treatment options for mid-shaft clavicle fractures; the latter method has demonstrated better performance in some studies. Objectives. Our aim was to critically review and summarize the literature comparing the outcomes of mid-shaft clavicle fracture treatment with plate fixation or intramedullary fixation to identify the better approach. Search Methods. Potential academic articles were identified from the Cochrane Library, MEDLINE (1966-2015.5), PubMed (1966-2015.5), EMBASE (1980-2015.5) and ScienceDirect (1966-2015.5). Gray studies were identified from the references of the included literature. Selection Criteria. Randomized controlled trials (RCTs) and non-RCTs comparing plate fixation and intramedullary fixation for mid-shaft clavicle fracture were included. Data Collection and Analysis. Two reviewers performed independent data abstraction. The I2 statistic was used to assess heterogeneity. A fixed- or random-effects model was used for the meta-analysis. Results. Six RCTs and nine non-RCTs were retrieved, including 513 patients in the intramedullary fixation group and 521 patients in the plating group. No significant differences in terms of the union rate and shoulder function were found between the groups. Patients in the intramedullary fixation group had a shorter operative time, less blood loss, smaller wound size, and shorter union time than those in the plating group. With respect to complications, significant differences were identified for all complications and major complications (wound infection, nonunion, implant failures, transient brachial plexopathy, and pain after 6 months). Similar secondary complications (symptomatic hardware, hardware irritation, prominence, numbness, hypertrophic callus) were observed in both groups. Conclusions. Intramedullary fixation may be superior to plate fixation in the treatment of mid-shaft clavicle fractures, with similar

  13. Plating versus intramedullary fixation for mid-shaft clavicle fractures: a systemic review and meta-analysis.

    PubMed

    Gao, Yan; Chen, Wei; Liu, Yue-Jv; Li, Xu; Wang, Hai-Li; Chen, Zhao-Yu

    2016-01-01

    Background. Plate fixation and intramedullary fixation are the most commonly used surgical treatment options for mid-shaft clavicle fractures; the latter method has demonstrated better performance in some studies. Objectives. Our aim was to critically review and summarize the literature comparing the outcomes of mid-shaft clavicle fracture treatment with plate fixation or intramedullary fixation to identify the better approach. Search Methods. Potential academic articles were identified from the Cochrane Library, MEDLINE (1966-2015.5), PubMed (1966-2015.5), EMBASE (1980-2015.5) and ScienceDirect (1966-2015.5). Gray studies were identified from the references of the included literature. Selection Criteria. Randomized controlled trials (RCTs) and non-RCTs comparing plate fixation and intramedullary fixation for mid-shaft clavicle fracture were included. Data Collection and Analysis. Two reviewers performed independent data abstraction. The I (2) statistic was used to assess heterogeneity. A fixed- or random-effects model was used for the meta-analysis. Results. Six RCTs and nine non-RCTs were retrieved, including 513 patients in the intramedullary fixation group and 521 patients in the plating group. No significant differences in terms of the union rate and shoulder function were found between the groups. Patients in the intramedullary fixation group had a shorter operative time, less blood loss, smaller wound size, and shorter union time than those in the plating group. With respect to complications, significant differences were identified for all complications and major complications (wound infection, nonunion, implant failures, transient brachial plexopathy, and pain after 6 months). Similar secondary complications (symptomatic hardware, hardware irritation, prominence, numbness, hypertrophic callus) were observed in both groups. Conclusions. Intramedullary fixation may be superior to plate fixation in the treatment of mid-shaft clavicle fractures, with similar

  14. Thermal protection system gap heating rates of the Rockwell International flat plate heat transfer model (OH2A/OH2B)

    NASA Technical Reports Server (NTRS)

    Foster, T. F.; Lockman, W. K.; Grifall, W. J.

    1973-01-01

    Heat transfer data for the Rockwell International Flat Plate Thermocouple Model are presented. The model simulated the Space Shuttle Vehicle Thermal Protection System. Data were recorded for locations in and around various size gaps for various gap orientation configurations. The test was conducted at Mach 5.1 for free-stream Reynolds number per foot values from 500,000 to 1,500,000.

  15. Novel Pedicle Screw and Plate System Provides Superior Stability in Unilateral Fixation for Minimally Invasive Transforaminal Lumbar Interbody Fusion: An In Vitro Biomechanical Study

    PubMed Central

    Zhu, Qingan; Zhou, Yue; Li, Changqing; Liu, Huan; Huang, Zhiping; Shang, Jin

    2015-01-01

    Purpose This study aims to compare the biomechanical properties of the novel pedicle screw and plate system with the traditional rod system in asymmetrical posterior stabilization for minimally invasive transforaminal lumbar interbody fusion (MI-TLIF). We compared the immediate stabilizing effects of fusion segment and the strain distribution on the vertebral body. Methods Seven fresh calf lumbar spines (L3-L6) were tested. Flexion/extension, lateral bending, and axial rotation were induced by pure moments of ± 5.0 Nm and the range of motion (ROM) was recorded. Strain gauges were instrumented at L4 and L5 vertebral body to record the strain distribution under flexion and lateral bending (LB). After intact kinematic analysis, a right sided TLIF was performed at L4-L5. Then each specimen was tested for the following constructs: unilateral pedicle screw and rod (UR); unilateral pedicle screw and plate (UP); UR and transfacet pedicle screw (TFS); UP and TFS; UP and UR. Results All instrumented constructs significantly reduced ROM in all motion compared with the intact specimen, except the UR construct in axial rotation. Unilateral fixation (UR or UP) reduced ROM less compared with the bilateral fixation (UP/UR+TFS, UP+UR). The plate system resulted in more reduction in ROM compared with the rod system, especially in axial rotation. UP construct provided more stability in axial rotation compared with UR construct. The strain distribution on the left and right side of L4 vertebral body was significantly different from UR and UR+TFS construct under flexion motion. The strain distribution on L4 vertebral body was significantly influenced by different fixation constructs. Conclusions The novel plate could provide sufficient segmental stability in axial rotation. The UR construct exhibits weak stability and asymmetrical strain distribution in fusion segment, while the UP construct is a good alternative choice for unilateral posterior fixation of MI-TLIF. PMID:25807513

  16. Shear wave splitting observations across the Juan de Fuca plate system: Ridge- to-trench constraints on mantle flow from 2 years of Cascadia Initiative OBS data

    NASA Astrophysics Data System (ADS)

    Bodmer, M.; Toomey, D. R.; Hooft, E. E. E.

    2014-12-01

    We present SKS splitting measurements for the first two years of data collected by the Cascadia Initiative (CI) amphibious array. Our analysis includes observations from over 100 ocean bottom seismometers (OBS), as well as 31 onshore stations, and spans both the Juan de Fuca and Gorda plates. The CI dataset is unique in that it includes several regions that can distinctly influence anisotropic fabric development such as: the upwelling mantle beneath the Juan de Fuca and Gorda ridges, the young evolving oceanic lithosphere of the plate interior, the Blanco transform fault, and the Cascadia subduction zone. For the first time, we are able to analyze these regions with a single dataset, and using a common methodology. Splitting measurements are routinely done on land sites, but have been completed on relatively few OBS stations. This is largely due to the low signal to noise present in OBS data, which can obscure the splitting results. To address that nearly all the OBS data exceeds the global high noise limit at the frequencies used for splitting, we implement a rigorous quality control scheme. Our method specifically takes into account the response of common splitting methods to high noise data and addresses known issues such as cycle skipping, false minima, low transverse energy, and near-null measurements. Individual measurements are filtered at 0.03-0.1 Hz, manually checked for quality, and stacked. Preliminary results show trench perpendicular onshore measurements consistent with previous studies. Oceanic measurements in the plate interior show a coherent fast axis roughly aligned with absolute plate motion. Several measurements near the ridge and trench appear to be rotated in the ridge and trench parallel directions. Continuing work will integrate splitting measurements from the final two years of the CI with these findings, which will be used to characterize the ridge-to-trench mantle flow across the Juan de Fuca plate system.

  17. Structure of the Lithosphere-Asthenosphere System Beneath the Juan de Fuca Plate: Results of Body Wave Imaging Using Cascadia Initiative Data

    NASA Astrophysics Data System (ADS)

    Byrnes, J. S.; Toomey, D. R.; Hooft, E. E. E.

    2014-12-01

    The plate-scale deployment of ocean bottom seismometers (OBS) as part of the Cascadia Initiative (CI) of NSF provides a unique opportunity to study the structure and dynamics of the lithosphere-asthenosphere system beneath an entire oceanic plate, from its birth at a spreading center to its subduction beneath a continent. Here we present tomographic images of the seismic structure of oceanic upper mantle beneath the Juan de Fuca (JdF) and Gorda plates derived from body wave delay times. The results constrain structural anomalies beneath the JdF and Gorda spreading centers, the Blanco and Mendocino transform faults, near ridge hotspots such as Axial Seamount, and the upper mantle structure beneath the subducting oceanic lithosphere. We measured delay times of teleseismic P and S wave phases for the first two years of the CI. Our tomographic analysis assumes both isotropic and anisotropic starting models and accounts for finite-frequency effects and three-dimensional ray bending. Preliminary results indicate that the upper mantle structure beneath the JdF spreading center is asymmetric, with lower shear wave velocities beneath the Pacific plate (also the direction of ridge migration). On a regional scale, regions of lower seismic velocities beneath the JdF and Gorda spreading centers correlate with shallower ridge depths. Beneath the southern Gorda plate a low velocity anomaly is detected, which is absent to the north; this anomaly is bounded to the south by the Mendocino transform. Ongoing work includes analysis of the third year of CI data, which will improve resolution of structure and allow better definition of anomalies in the vicinity of the Blanco transform. In addition, we will combine ocean and continental data to obtain images of the Cascadia subduction zone.

  18. In vivo degradation of magnesium plate/screw osteosynthesis implant systems: Soft and hard tissue response in a calvarial model in miniature pigs.

    PubMed

    Schaller, Benoit; Saulacic, Nikola; Imwinkelried, Thomas; Beck, Stefan; Liu, Edwin Wei Yang; Gralla, Jan; Nakahara, Ken; Hofstetter, Willy; Iizuka, Tateyuki

    2016-03-01

    Biodegradable magnesium plate/screw osteosynthesis systems were implanted on the frontal bone of adult miniature pigs. The chosen implant geometries were based on existing titanium systems used for the treatment of facial fractures. The aim of this study was to evaluate the in vivo degradation and tissue response of the magnesium alloy WE43 with and without a plasma electrolytic surface coating. Of 14 animals, 6 received magnesium implants with surface modification (coated), 6 without surface modification (uncoated), and 2 titanium implants. Radiological examination of the skull was performed at 1, 4, and 8 weeks post-implantation. After euthanasia at 12 and 24 weeks, X-ray, computed tomography, and microfocus computed tomography analyses and histological and histomorphological examinations of the bone/implant blocks were performed. The results showed a good tolerance of the plate/screw system without wound healing disturbance. In the radiological examination, gas pocket formation was found mainly around the uncoated plates 4 weeks after surgery. The micro-CT and histological analyses showed significantly lower corrosion rates and increased bone density and bone implant contact area around the coated screws compared to the uncoated screws at both endpoints. This study shows promising results for the further development of coated magnesium implants for the osteosynthesis of the facial skeleton. PMID:26805919

  19. The Golosyiv plate archive digitisation

    NASA Astrophysics Data System (ADS)

    Sergeeva, T. P.; Sergeev, A. V.; Pakuliak, L. K.; Yatsenko, A. I.

    2007-08-01

    The plate archive of the Main Astronomical Observatory of the National Academy of Sciences of Ukraine (Golosyiv, Kyiv) includes about 85 000 plates which have been taken in various observational projects during 1950-2005. Among them are about 25 000 of direct northern sky area plates and more than 600 000 plates containing stellar, planetary and active solar formations spectra. Direct plates have a limiting magnitude of 14.0-16.0 mag. Since 2002 we have been organising the storage, safeguarding, cataloguing and digitization of the plate archive. The very initial task was to create the automated system for detection of astronomical objects and phenomena, search of optical counterparts in the directions of gamma-ray bursts, research of long period, flare and other variable stars, search and rediscovery of asteroids, comets and other Solar System bodies to improve the elements of their orbits, informational support of CCD observations and space projects, etc. To provide higher efficiency of this work we have prepared computer readable catalogues and database for 250 000 direct wide field plates. Now the catalogues have been adapted to Wide Field Plate Database (WFPDB) format and integrated into this world database. The next step will be adaptation of our catalogues, database and images to standards of the IVOA. Some magnitude and positional accuracy estimations for Golosyiv archive plates have been done. The photometric characteristics of the images of NGC 6913 cluster stars on two plates of the Golosyiv's double wide angle astrograph have been determined. Very good conformity of the photometric characteristics obtained with external accuracies of 0.13 and 0.15 mag. has been found. The investigation of positional accuracy have been made with A3± format fixed bed scanner (Microtek ScanMaker 9800XL TMA). It shows that the scanner has non-detectable systematic errors on the X-axis, and errors of ± 15 μm on the Y-axis. The final positional errors are about ± 2 μm (

  20. Geodynamics of flat-slab subduction, sedimentary basin development, and hydrocarbon systems along the southern Alaska convergent plate margin

    NASA Astrophysics Data System (ADS)

    Finzel, Emily S.

    Combining field-based geologic studies and numerical modeling provides a robust tool for evaluating the geodynamics of convergent margins. Southern Alaska is arguably the most tectonically active part of the convergent margin of western North America. This conceptual approach has been used to interpret the modern basin dynamics, as well as key stages in the Cenozoic development of this region, including spreading-ridge and flat-slab subduction. New macrofossil, palynological, and lithostratigraphic data for the Bear Lake Formation in the Bristol Bay retroarc basin allow us to construct the first chronostratigraphic framework for this formation, and indicate deposition during Middle and Late Miocene time in a regional transgressive estuarine depositional system. In the Cook Inlet forearc basin, new detrital zircon U-Pb geochronology, rare earth element geochemistry, and clast compositional data from middle Eocene-Pliocene strata demonstrate the importance of sediment sources located in the retroarc region and along strike within the basin. The Yakutat microplate has recently been reinterpreted to represent buoyant crust that is presently subducting at a shallow angle beneath southern Alaska. Integration of stratigraphic, geochronologic, and thermochronologic data indicate that in the flat-slab region, exhumation initiated ca. 43 Ma and migrated inboard, magmatism ceased at ca. 32 Ma, and deposition in sedimentary basins ended by ca. 23 Ma. Sedimentary basins positioned along the western and northern perimeter of the flat-slab region record enhanced subsidence and sediment delivery from the flat-slab region beginning in late Oligocene and middle Miocene time respectively. The discrete contributions of unique driving forces for lithospheric deformation in western Canada and Alaska have not been quantified in detail, so their relative role in influencing deformation has remained unresolved. Using finite element models, we calculate a continuous strain rate and velocity

  1. Kinematic model for out-of-sequence thrusting: Motion of two ramp-flat faults and the production of upper plate duplex systems

    NASA Astrophysics Data System (ADS)

    Pavlis, Terry L.

    2013-06-01

    Kinematic models developed here suggest a bewildering array of structural styles can be generated during out-of-sequence thrusting. Many of these structures would be difficult to distinguish from a normally stacked thrust sequence and the process can produce younger-on-older faults that could easily be misinterpreted as normal faults. This paper considers a small subset of this problem within a large model space by considering structures that develop along a pair of ramp-flat faults that are moving simultaneously, or sequentially. Motion on the lower ramp warps the structurally higher fault due to fault-bend folding and when the fault ruptures through the warp it transfers a horse to the upper hanging wall. Continuity of the process generates what is referred to here as an "upper plate duplex" to distinguish the structure from a conventional duplex. Kinematic parameters are developed for two models within this general problem: 1) a system with a fixed ramp in the lower thrust, overridden by an upper thrust; and 2) a double-duplex system where a conventional duplex develops along the lower fault at the same time as an upper plate duplex is formed along the upper fault. The theory is tested with forward models using 2D Move software and these tests indicate different families of structural styles form in association with relative scaling of ramp systems, slip-ratio between faults, and aspect ratios of horse blocks formed in the upper-plate duplex. A first-order result of the analysis is that an upper plate duplex can be virtually indistinguishable from a conventional duplex unless the trailing branch lines of the horses are exposed or imaged; a condition seldom met in natural exposures. Restoration of an upper-plate duplex produces counterintuitive fault geometry in the restored state, and thus, restorations of upper plate duplexes that erroneously assume a conventional duplex model would produce restored states that are seriously in error. In addition, in most of

  2. Plated wire memory subsystem

    NASA Technical Reports Server (NTRS)

    Carpenter, K. H.

    1974-01-01

    The design, construction, and test history of a 4096 word by 18 bit random access NDRO Plated Wire Memory for use in conjunction with a spacecraft input/output and central processing unit is reported. A technical and functional description is given along with diagrams illustrating layout and systems operation. Test data is shown on the procedures and results of system level and memory stack testing, and hybrid circuit screening. A comparison of the most significant physical and performance characteristics of the memory unit versus the specified requirements is also included.

  3. A simulation study of a dual-plate in-room PET system for dose verification in carbon ion therapy

    NASA Astrophysics Data System (ADS)

    Chen, Ze; Hu, Zheng-Guo; Chen, Jin-Da; Zhang, Xiu-Ling; Guo, Zhong-Yan; Xiao, Guo-Qing; Sun, Zhi-Yu; Huang, Wen-Xue; Wang, Jian-Song

    2014-08-01

    During carbon ion therapy, lots of positron emitters such as 11C, 15O, 10C are generated in irradiated tissues by nuclear reactions, and can be used to track the carbon beam in the tissue by a positron emission tomography (PET) scanner. In this study, an dual-plate in-room PET scanner has been designed and evaluated based on the GATE simulation platform to monitor patient dose in carbon ion therapy. The dual-plate PET is designed to avoid interference with the carbon beamline and with patient positioning. Its performance was compared with that of four-head and full-ring PET scanners. The dual-plate, four-head and full-ring PET scanners consisted of 30, 60, 60 detector modules, respectively, with a 36 cm distance between directly opposite detector modules for dose deposition measurements. Each detector module consisted of a 24×24 array of 2 mm×2 mm×18 mm LYSO pixels coupled to a Hamamatsu H8500 PMT. To estimate the production yield of positron emitters, a 10 cm×15 cm×15 cm cuboid PMMA phantom was irradiated with 172, 200, 250 MeV/u 12C beams. 3D images of the activity distribution measured by the three types of scanner are produced by an iterative reconstruction algorithm. By comparing the longitudinal profile of positron emitters along the carbon beam path, it is indicated that use of the dual-plate PET scanner is feasible for monitoring the dose distribution in carbon ion therapy.

  4. Measuring the efficacy of flunixin meglumine and meloxicam for lame sows using a GAITFour pressure mat and an embedded microcomputer-based force plate system.

    PubMed

    Pairis-Garcia, M D; Johnson, A K; Abell, C A; Coetzee, J F; Karriker, L A; Millman, S T; Stalder, K J

    2015-05-01

    Pain associated with lameness on farm is a negative affective state and has a detrimental impact on individual farm animal welfare. Animal pain can be managed utilizing husbandry tools and through pharmacological approaches. Nonsteroidal anti-inflammatory drugs including meloxicam and flunixin meglumine are compounds used in many species for pain management because they are easy to administer, long lasting, and cost-effective. Assessing an animal's biomechanical parameters using such tools as the embedded microcomputer-based force plate system and GAITFour pressure mat gait analysis walkway system provides an objective, sensitive, and precise means to detect animals in lame states. The objectives of this study were to determine the efficacy of meloxicam and flunixin meglumine for pain mitigation in lame sows using the embedded microcomputer-based force plate system and GAITFour pressure mat gait analysis walkway system. Lameness was induced in 24 mature mixed-parity sows using a chemical synovitis model and compared 3 treatments: meloxicam (1.0 mg/kg per os), flunixin meglumine (2.2 mg/kg intramuscular) and sterile saline (intramuscular). Weight distribution (kg) for each foot was collected twice per second for a total of 5 min for each time point using the embedded microcomputer-based force plate system. Stride time, stride length, maximum pressure, activated sensors, and stance time were collected using 3 quality walks (readings) for each time point using the GAITFour pressure mat gait analysis walkway system. Sows administered flunixin meglumine or meloxicam tolerated more weight on their lame leg compared with saline sows (P < 0.005). Sows administered flunixin meglumine or meloxicam had smaller differences in stance time, maximum pressure, and activated sensors between the sound and lame legs compared with saline-treated sows between 37 and 60 h after lameness induction (P < 0.03). In conclusion, flunixin meglumine and meloxicam administration mitigated pain

  5. Peridinialean dinoflagellate plate patterns, labels and homologies

    USGS Publications Warehouse

    Edwards, L.E.

    1990-01-01

    Tabulation patterns for peridinialean dinoflagellate thecae and cysts have been traditionally expressed using a plate labelling system described by C.A. Kofoid in the early 1900's. This system can obscure dinoflagellate plate homologies and has not always been strictly applied. The plate-labelling system presented here introduces new series labels but incorporates key features and ideas from the more recently proposed systems of G.L. Eaton and F.J.R. Taylor, as modified by W.R. Evitt. Plate-series recognition begins with the cingulum (C-series) and proceeds from the cingulum toward the apex for the three series of the epitheca/epicyst and proceeds from the cingulum toward the antapex for the two series of the hypotheca/hypocyst. The epithecal/epicystal model consists of eight plates that touch the anterior margin of the cingulum (E-series: plates E1-E7, ES), seven plates toward the apex that touch the E-series plates (M-series: R, M1-M6), and up to seven plates near the apex that do not touch E-series plates (D-series: Dp-Dv). The hypothecal/hypocystal model consists of eight plates that touch the posterior margin of the cingulum (H-series: H1-H6,HR,HS) and three plates toward the antapex (T1-T3). Epithecal/epicystal tabulation patterns come in both 8- and 7- models, corresponding to eight and seven plates, respectively, in the E-series. Hypothecal/hypocystal tabulation patterns also come in both 8- and 7-models, corresponding to eight and seven plates, respectively, in the H-series. By convention, the 7-model epitheca/epicyst has no plates E1 and M1; the 7-model hypotheca/hypocyst has no plate H6. Within an 8-model or 7-model, the system emphasizes plates that are presumed to be homologous by giving them identical labels. I introduce the adjectives "monothigmate", "dithigmate," and "trithigmate" to designate plates touching one, two, and three plates, respectively, of the adjacent series. The term "thigmation" applies to the analysis of plate contacts between

  6. Sputtering and ion plating

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The proceedings of a conference on sputtering and ion plating are presented. Subjects discussed are: (1) concepts and applications of ion plating, (2) sputtering for deposition of solid film lubricants, (3) commercial ion plating equipment, (4) industrial potential for ion plating and sputtering, and (5) fundamentals of RF and DC sputtering.

  7. Development and testing of a multiwell plates absorbance reader for clinical analysis using inexpensive webcam

    NASA Astrophysics Data System (ADS)

    Castillo, Jimmy; Gutierrez, Hector; Vitta, Yosmery; Martinez, Mauro; Fernandez, Alberto

    2007-09-01

    Biochemical analysis and clinical tests like glucose, hemoglobin, cholesterol, iron, etc. are crucial for early illness diagnosis like diabetes, anemia and coronary deceases. These tests usually are done in state of the art instruments in well equipped laboratories in health centers. In some cases, these instruments are not portable, so they are not recommended for clinical field studies in remote areas. The present work shows a portable low-cost prototype of multi-well plates reader designed for clinical analysis. A Light Emission Diodes (LEDs) array is used as excitation source and an inexpensive webcam as detector. The light source illuminates the 96 well plates and the webcam take the image with 640x480 pixels. The data is acquired and processed by using a portable computer. 96 samples can be read including blanks and calibration standards simultaneously. Light absorption data are processed using a MatLab software designed in our laboratory to obtain calibration curves, standards lectures and samples concentration. The system was evaluated using different analytes series solutions: Neutral Red, Cooper (II) Ammonia Complex and Methyl Orange. The results shows that it is possible to measure few micro liters of solutions with adequate exactitude and precision of less than 3%. As possible analytical clinical application, iron determination was performed using Fe(III) Thiocyanate complex. This method is usually applied in serum samples analysis. The sensibility achieved with the proposed instrumentation configurations allows the analysis of iron in serum samples in the references values normal range (0.75 - 1.5 mg/L) in human.

  8. The contribution of the Volcano Observations Work Package to the implementation of the European Plate Observing System

    NASA Astrophysics Data System (ADS)

    Puglisi, Giuseppe

    2016-04-01

    The overall aim of the implementation phase of European Plate Observing System (EPOS) is to make the integrated platform operational in order to guarantee seamless access to the data provided by the European Solid Earth communities. The Volcano Observations Work Package (WP11) contributes to this objective by implementing a Thematic Core Service (TCS) which is planned to give access to the data and services provided by the European Volcano Observatories (VO) and some Volcanological Research Institutions (VRI; such as university departments, laboratories, etc.). Both types are considered as national research infrastructures (RI) which the TCS will integrate. Currently, monitoring networks on European volcanoes consist of thousands of stations or sites where volcanological parameters are continuously or periodically measured. These sites are equipped with instruments for geophysical (seismic, geodetic, gravimetric, electromagnetic), geochemical (volcanic plumes, fumaroles, groundwater, rivers, soils), environmental observations (e.g. meteorological and air quality parameters), as well as various prototypal monitoring systems (e.g. Doppler radars, ground based SAR). Across Europe several laboratories provide sample characterization (rocks, gases, isotopes, etc.), quasi-continuous analysis of space-borne data (SAR, thermal imagery, SO2 and ash), as well as high-performance computing facilities. All these RIs provide high-quality information (observations) on the current status of European volcanoes and the geodynamic background of the surrounding areas. The implementation of the Volcano Observations TCS will address technical as well as managerial issues, both considering the current heterogeneous state-of-the-art of the volcanological research infrastructures in Europe. Indeed, the current arrangement of individual VO and VRI is considered too fragmented to be considered as a unique distributed infrastructure. Therefore, the main effort in the framework of the EPOS

  9. Development of a high-throughput purification method and a continuous assay system for chlorophyllase.

    PubMed

    Arkus, Kiani A J; Jez, Joseph M

    2006-06-01

    In the degradation of chlorophyll, chlorophyllase catalyzes the initial hydrolysis of the phytol moiety from the pigment. Since chlorophyll degradation is a defining feature of plant senescence, compounds inhibiting chlorophyllase activity may delay senescence, thereby improving shelf life and appearance of plant products. Here we describe the development of a 96-well plate-based purification and assay system for measuring chlorophyllase activity. Integrated lysis and immobilized metal affinity chromatography plates were used for purifying recombinant hexahistidine-tagged Triticum aestivum (wheat) chlorophyllase from Escherichia coli. Chlorophyllase assays using chlorophyll as a substrate showed that the immobilized fusion protein displayed kinetic parameters similar to those of recombinant enzyme purified by affinity chromatography; however, the need to extract reaction products from a multiwell plate limits the value of this assay for high-throughput screening applications. Replacing chlorophyll with p-nitrophenyl-ester substrates eliminates the extraction step and allows for continuous measurement of chlorophyllase activity in a multiwell plate format. Determination of steady state kinetic constants, pH rate profile, the inhibitory effects of metal ions and esterase inhibitors, and the effect of functional group-modifying reagents validated the utility of the plate-based system. The combined purification and assay system provides a convenient and rapid method for the assessment of chlorophyllase activity. PMID:16643837

  10. Current global plate kinematics from GPS (1995-2007) with the plate-consistent reference frame

    NASA Astrophysics Data System (ADS)

    Kogan, Mikhail G.; Steblov, Grigory M.

    2008-04-01

    We present the vectors of rotation of 10 major lithospheric plates, estimated from continuous GPS observations at 192 globally distributed stations; 71 stations were selected as representing stable plate regions. All days for the period 1995.0-2007.0 were included in the analysis. In contrast to previous GPS plate models, our model is independent of international terrestrial reference frames (ITRF). The origin of our plate-consistent reference frame is the center of plate rotation (CP) rather than the center of mass of the entire Earth's system (CM) as in recent versions of ITRF. We estimate plate rotations and CP by minimizing the misfit between the horizontal velocities predicted by the plate model and the observed GPS velocities. If any version of ITRF is used as the reference frame, the drift of the ITRF origin relative to CP cannot be neglected in estimation of plate rotation vectors and plate-residual station velocities. The model of the plate kinematics presented here addresses the problem debated since the beginning of the space geodesy: how big are disagreements between the current plate motions and the motions averaged over several million years? We compare the vectors of relative plate rotations estimated here with the published vectors from GPS and geologic models. We also discuss the integrity of individual plates as exhibited by plate-residual station velocities. For seven largest plates, the RMS value of plate-residual station velocities in stable plate interiors is 0.5-0.9 mm/a; this value is an upper bound on deviation of real plates from infinite stiffness.

  11. Measurement of spatial distribution of neutrons and gamma rays for BNCT using multi-imaging plate system.

    PubMed

    Tanaka, Kenichi; Sakurai, Yoshinori; Tanaka, Hiroki; Kajimoto, Tsuyoshi; Takata, Takushi; Takada, Jun; Endo, Satoru

    2015-12-01

    Quality assurance of the spatial distributions of neutrons and gamma rays was tried using imaging plates (IPs) and converters to enhance the beam components in the epithermal neutron mode of the Kyoto University Reactor. The converters used were 4mm thick epoxy resin with B4C at 6.85 weight-percent (wt%) (10)B for epithermal neutrons, and 3mm thick carbon for gamma rays. Results suggested that the IP signal does not need a sensitivity correction regardless of the incident radiation that produces it. PMID:26278346

  12. MerMade: An Oligodeoxyribonucleotide Synthesizer for High Throughput Oligonucleotide Production in Dual 96-Well Plates

    PubMed Central

    Rayner, Simon; Brignac, Stafford; Bumeister, Ron; Belosludtsev, Yuri; Ward, Travis; Grant, O’dell; O’Brien, Kevin; Evans, Glen A.; Garner, Harold R.

    1998-01-01

    We have designed and constructed a machine that synthesizes two standard 96-well plates of oligonucleotides in a single run using standard phosphoramidite chemistry. The machine is capable of making a combination of standard, degenerate, or modified oligos in a single plate. The run time is typically 17 hr for two plates of 20-mers and a reaction scale of 40 nm. The reaction vessel is a standard polypropylene 96-well plate with a hole drilled in the bottom of each well. The two plates are placed in separate vacuum chucks and mounted on an xy table. Each well in turn is positioned under the appropriate reagent injection line and the reagent is injected by switching a dedicated valve. All aspects of machine operation are controlled by a Macintosh computer, which also guides the user through the startup and shutdown procedures, provides a continuous update on the status of the run, and facilitates a number of service procedures that need to be carried out periodically. Over 25,000 oligos have been synthesized for use in dye terminator sequencing reactions, polymerase chain reactions (PCRs), hybridization, and RT–PCR. Oligos up to 100 bases in length have been made with a coupling efficiency in excess of 99%. These machines, working in conjunction with our oligo prediction code are particularly well suited to application in automated high throughput genomic sequencing. PMID:9685322

  13. Characterization of gas-liquid mass transfer phenomena in microtiter plates.

    PubMed

    Hermann, Robert; Lehmann, Mathias; Büchs, Jochen

    2003-01-20

    Gas-liquid mass transfer properties of shaken 96-well microtiter plates were characterized using a recently described method. The maximum oxygen transfer capacity (OTR(max)), the specific mass transfer area (a), and the mass transfer coefficient (k(L)) in a single well were determined at different shaking intensities (different shaking frequencies and shaking diameters at constant filling volume) and different filling volumes by means of sulfite oxidation as a chemical model system. The shape (round and square cross-sections) and the size (up to 2 mL maximum filling volume) of a microtiter plate well were also considered as influencing parameters. To get an indication of the hydrodynamic behavior of the liquid phase in a well, images were taken during shaking and the liquid height derived as a characteristic parameter. The investigations revealed that the OTR(max) is predominantly dependent on the specific mass transfer area (a) for the considered conditions in round-shaped wells. The mass transfer coefficient (k(L)) in round-shaped wells remains at a nearly constant value of about 0.2 m/h for all shaking intensities, thus within the range reported in the literature for surface-aerated bioreactors. The OTR(max) in round-shaped wells is strongly influenced by the interfacial tension, determined by the surface tension of the medium used and the surface properties of the well material. Up to a specific shaking intensity the liquid surface in the wells remains horizontal and no liquid movement can be observed. This critical shaking intensity must be exceeded to overcome the surface tension and, thus, to increase the liquid height and enlarge the specific mass transfer area. This behavior is solely specific to microtiter plates and has not yet been observed for larger shaking bioreactors such as shaking flasks. In square-shaped microtiter plate wells the corners act as baffles and cause a significant increase of OTR(max), a, and k(L). An OTR(max) of up to 0.15 mol

  14. Reduced hydrogen cadmium plating

    SciTech Connect

    Hoeller, T.; Ross, L. ); Varma, R. ); Agarwala, V.S. )

    1991-01-01

    This paper demonstrates the advantages of using a periodic reverse pulse plating method, incorporating a fast cathodic pulse which is separated from the subsequent anodic/cathodic pulses by a long rest period in producing silvery cadmium coatings on steel from aqueous fluoroborate electrolyte. Also, the deposition obtained by combination of pulse currents and turbulent electrolyte flow system (forced convection of electrolyte, Re {approximately} 20-25,000) result in a near hydrogen-free electrodeposition of fine- grained cadmium. This is confirmed by the determination of diffusible hydrogen by the electrochemical (Barnach Electrode) method.

  15. Efficient DNA sequencing on microtiter plates using dried reagents and Bst DNA polymerase.

    PubMed

    Earley, J J; Kuivaniemi, H; Prockop, D J; Tromp, G

    1993-01-01

    Sequenase, Taq DNA polymerase and Bst DNA polymerase were tested for sequencing of DNA on microtiter plates using dried down reagents. Several parameters were investigated to expedite the drying process while minimizing damage to the enzyme. Sequenase did not tolerate drying very well, and frequently generated sequences with weak signals and many sites of premature termination. With Taq DNA polymerase it was possible to obtain sequences of good quality. However, there was considerable variation of results between experiments and between batches of microtiter plates. Bst DNA polymerase generated sequences of excellent quality. It was stable for more than a week in dried-down state at -20 degrees C and at least overnight at room temperature. The method described here using Bst DNA polymerase is well suited for laboratory robots and workstations that typically employ 96-well microtiter plates. PMID:8173079

  16. Ultramicroband array electrode. 1. Analysis of mercury in contaminated soils and flue gas exposed samples using a gold-plated iridium portable system by anodic stripping voltammetry

    SciTech Connect

    Xiao, L.; Dietze, W.; Nyasulu, F.; Mibeck, B.A.F.

    2006-07-15

    The applicability of a gold-plated iridium Nano-Band array ultramicroelectrode (6 {mu}m by 0.2 {mu}m, 64-{mu}m interspacing, 100 electrode bands) in the analysis of mercury using a portable system is demonstrated by anodic stripping voltammetry in real-life samples. Optimized measurement parameters, 0.1 M HCl electrolyte, plating potential of 0 mV, and staircase scan mode were identified. The dynamic linear range is 10-180 ppb at 5-s deposition time with 1.5 {mu}C of gold plated. The experimental detection limit for Hg{sup 2+} in 0.1 M HCl was 0.5 ppb at a deposition time of 4 min and a scan rate of 10 V/s. Real-life samples, such as flue gas exposed samples from flue gas simulators could be analyzed within 5 min using the method of standard additions. We identified a field-portable extraction procedure for soil samples using 1:1 concentrated HNO{sub 3}/30% H{sub 2}O{sub 2} mixture, compatible with ASV and the iridium electrode. The detection limit for soils is 1 ppm. The results obtained using ASV are in good agreement with reference values using cold vapor atomic absorption for the sample matrixes studied here. To our knowledge, this is the first mercury application using a reusable iridium array ultramicroelectrode. The portable potentiostat is less than 500 g, and together with the portable digestion method, makes the Nano-Band Explorer system field applicable.

  17. Effect of inherited structures on strike-slip plate boundaries: insight from analogue modelling of the central Levant Fracture System, Lebanon

    NASA Astrophysics Data System (ADS)

    Ghalayini, Ramadan; Daniel, Jean-Marc; Homberg, Catherine; Nader, Fadi

    2015-04-01

    Analogue sandbox modeling is a tool to simulate deformation style and structural evolution of sedimentary basins. The initial goal is to test what is the effect of inherited and crustal structures on the propagation, evolution, and final geometry of major strike-slip faults at the boundary between two tectonic plates. For this purpose, we have undertaken a series of analogue models to validate and reproduce the structures of the Levant Fracture System, a major NNE-SSW sinistral strike-slip fault forming the boundary between the Arabian and African plates. Onshore observations and recent high quality 3D seismic data in the Levant Basin offshore Lebanon demonstrated that Mesozoic ENE striking normal faults were reactivated into dextral strike-slip faults during the Late Miocene till present day activity of the plate boundary which shows a major restraining bend in Lebanon with a ~ 30°clockwise rotation in its trend. Experimental parameters consisted of a silicone layer at the base simulating the ductile crust, overlain by intercalated quartz sand and glass sand layers. Pre-existing structures were simulated by creating a graben in the silicone below the sand at an oblique (>60°) angle to the main throughgoing strike-slip fault. The latter contains a small stepover at depth to create transpression during sinistral strike-slip movement and consequently result in mountain building similarly to modern day Lebanon. Strike-slip movement and compression were regulated by steady-speed computer-controlled engines and the model was scanned using a CT-scanner continuously while deforming to have a final 4D model of the system. Results showed that existing normal faults were reactivated into dextral strike-slip faults as the sinistral movement between the two plates accumulated. Notably, the resulting restraining bend is asymmetric and segmented into two different compartments with differing geometries. One compartment shows a box fold anticline, while the second shows an

  18. A Refined Shear Deformation Plate Theory

    NASA Astrophysics Data System (ADS)

    Liu, Yucheng

    2011-04-01

    An improved higher-order shear deformation theory of plates is presented in this paper. The theory is developed from the transverse shear deformation theory presented by Ambartsumian [11]. The present plate theory contains kinematics of higher-order displacement field of plates, a system of higher-order differential equilibrium equations in terms of the three generalized displacements of bending plates, and a system of boundary conditions at each edge of plate boundaries. The present shear deformation theory of plates is validated by applying it to solve torsional plates and simply supported plates. The obtained solutions using the present theory are compared with the solutions of other shear-deformation theories. A good agreement is achieved through these comparisons and the advantages of the present theory are clearly verified. The shear deformation plate theory presented here can be applied to the analysis of laminated composite plates to better predict their dynamic and static behaviors. The proposed theory should also be supplemented to the theory of finite element analysis for developing new shell elements.

  19. Earth's Decelerating Tectonic Plates

    SciTech Connect

    Forte, A M; Moucha, R; Rowley, D B; Quere, S; Mitrovica, J X; Simmons, N A; Grand, S P

    2008-08-22

    Space geodetic and oceanic magnetic anomaly constraints on tectonic plate motions are employed to determine a new global map of present-day rates of change of plate velocities. This map shows that Earth's largest plate, the Pacific, is presently decelerating along with several other plates in the Pacific and Indo-Atlantic hemispheres. These plate decelerations contribute to an overall, globally averaged slowdown in tectonic plate speeds. The map of plate decelerations provides new and unique constraints on the dynamics of time-dependent convection in Earth's mantle. We employ a recently developed convection model constrained by seismic, geodynamic and mineral physics data to show that time-dependent changes in mantle buoyancy forces can explain the deceleration of the major plates in the Pacific and Indo-Atlantic hemispheres.

  20. ASSEMBLY OF PARALLEL PLATES

    DOEpatents

    Groh, E.F.; Lennox, D.H.

    1963-04-23

    This invention is concerned with a rigid assembly of parallel plates in which keyways are stamped out along the edges of the plates and a self-retaining key is inserted into aligned keyways. Spacers having similar keyways are included between adjacent plates. The entire assembly is locked into a rigid structure by fastening only the outermost plates to the ends of the keys. (AEC)

  1. Accelerated plate tectonics.

    PubMed

    Anderson, D L

    1975-03-21

    The concept of a stressed elastic lithospheric plate riding on a viscous asthenosphere is used to calculate the recurrence interval of great earthquakes at convergent plate boundaries, the separation of decoupling and lithospheric earthquakes, and the migration pattern of large earthquakes along an arc. It is proposed that plate motions accelerate after great decoupling earthquakes and that most of the observed plate motions occur during short periods of time, separated by periods of relative quiescence. PMID:17799689

  2. Plating Tank Control Software

    1998-03-01

    The Plating Tank Control Software is a graphical user interface that controls and records plating process conditions for plating in high aspect ratio channels that require use of low current and long times. The software is written for a Pentium II PC with an 8 channel data acquisition card, and the necessary shunt resistors for measuring currents in the millampere range.

  3. Rotatable shear plate interferometer

    DOEpatents

    Duffus, Richard C.

    1988-01-01

    A rotatable shear plate interferometer comprises a transparent shear plate mounted obliquely in a tubular supporting member at 45.degree. with respect to its horizontal center axis. This tubular supporting member is supported rotatably around its center axis and a collimated laser beam is made incident on the shear plate along this center axis such that defocus in different directions can be easily measured.

  4. Beyond plate tectonics - Looking at plate deformation with space geodesy

    NASA Technical Reports Server (NTRS)

    Jordan, Thomas H.; Minster, J. Bernard

    1988-01-01

    The requirements that must be met by space-geodetic systems in order to constrain the horizontal secular motions associated with the geological deformation of the earth's surface are explored. It is suggested that in order to improve existing plate-motion models, the tangential components of relative velocities on interplate baselines must be resolved to an accuracy of less than 3 mm/yr. Results indicate that measuring the velocities between crustal blocks to + or - 5 mm/yr on 100-km to 1000-km scales can produce geologically significant constraints on the integrated deformation rates across continental plate-boundary zones such as the western United States.

  5. Production of 6cm x 6cm Micro-channel Plate Based Picosecond Photodetectors with the Argonne Small Tile Processing System (STPS)

    NASA Astrophysics Data System (ADS)

    Xia, Lei; Byrum, Karen; Demarteau, Marcel; Wagner, Robert; Walters, Dean; Wang, Jingbo; Xie, Junqi; Zhao, Huyue

    2015-04-01

    Microchannel plate (MCP) based photodetectors feature fast timing, good position resolution and compact form factor. However, traditional MCP photodetectors suffer from limited charge lifetime and high cost. The LAPPD collaboration, over the years, developed Atomic Layer Deposition (ALD) coated new generation MCP's and low cost glass packaging technology. Recently, the Argonne group commissioned its small form factor tile processing system and produced the first fully processed sealed photodetectors with glass packaging, using the ALD coated MCP's. We report the design, construction and commissioning of the system, and production of the first devices. Supported by the U. S. Department of Energy, Office of Science, Office of Basic Energy Sciences and Office of High Energy Physics under Contract DE-AC02-06CH11357.

  6. Multicolor printing plate joining

    NASA Technical Reports Server (NTRS)

    Waters, W. J. (Inventor)

    1984-01-01

    An upper plate having ink flow channels and a lower plate having a multicolored pattern are joined. The joining is accomplished without clogging any ink flow paths. A pattern having different colored parts and apertures is formed in a lower plate. Ink flow channels each having respective ink input ports are formed in an upper plate. The ink flow channels are coated with solder mask and the bottom of the upper plate is then coated with solder. The upper and lower plates are pressed together at from 2 to 5 psi and heated to a temperature of from 295 F to 750 F or enough to melt the solder. After the plates have cooled and the pressure is released, the solder mask is removed from the interior passageways by means of a liquid solvent.

  7. High-throughput system for screening of Cephalosporin C high-yield strain by 48-deep-well microtiter plates.

    PubMed

    Tan, Jun; Chu, Ju; Hao, Yuyou; Guo, Yuanxin; Zhuang, Yingping; Zhang, Siliang

    2013-03-01

    Improvement of microbial strains for the high-production of industrial products has been the hallmark of all commercial fermentation processes. Strain improvement has been conventionally achieved through mutation and selection. However, most of the screenings were performed in shake flasks, which made the screening procedure very complex, time-consuming, and inefficient. Most mutant spore suspension had no chance to be screened due to the low-throughput of shake flasks and had to be sacrificed. In this paper, in order to get a Cephalosporin C (CPC) high-yield stain, traditional mutagenesis was employed to obtain the mutant library and gave them the equal screening chance by a novel mixture culture method combined with high-throughput screening method. The good correlation of fermentation results between differing-scale cultivations confirmed the feasibility of utilizing the 48-deep microtiter plates as a scale-down tool instead of shake flasks for culturing high-aerobic microbes with long cultivation period. The microbioassay based on the antibacterial activity of CPC against Alcaligenes faecalis was used to select mutants. As a result, the high-yield strain W-6 was successfully screened out and the CPC titer was nearly 50 % higher than that of the parental strain in the shake flask. The CPC production of strain W-6 was further validated in 50 l bioreactor, and the CPC production reached 32.0 g/l, twofold higher than that of the wild strain. PMID:23334835

  8. Capacitive carbon and electrochemical lead electrode systems at the negative plates of lead-acid batteries and elementary processes on cycling

    NASA Astrophysics Data System (ADS)

    Pavlov, D.; Nikolov, P.

    2013-11-01

    Batteries in hybrid electric vehicles operate in High-Rate Partial-State-of-Charge (HRPSoC) cycling duty. To make lead-acid batteries suitable for this duty, carbon is added to the negative active material. As a result of this technological change, two electrical systems form at the negative plates: (a) a capacitive carbon system comprising high-rate charging and discharging of the electric double layer; low Ah capacity, and (b) a lead electrochemical system, comprising oxidation of Pb to PbSO4 during discharge and vice versa during charge; this system is slow to accept charge, but has high Ah capacity. Through cycling lead-acid cells under HRPSoC conditions with short current pulses of various durations we have established that the processes involved in the capacitive system proceed highly reversibly and complete hundreds of thousands HRPSoC cycles. The number of cycles achieved by the electrochemical system is limited to tens of thousands and lead to progressive sulfation. Carbon added to the negative active material changes the latter's structure. The specific surface of NAM increases and the median pore radius decreases. Some carbon additives may reduce the radius of the pores in NAM to membrane sizes, which may change the chemistry of the electrochemical system.

  9. 49 CFR 236.779 - Plate, top.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Plate, top. 236.779 Section 236.779 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF... OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.779 Plate, top....

  10. 49 CFR 236.779 - Plate, top.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Plate, top. 236.779 Section 236.779 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF... OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.779 Plate, top....

  11. 49 CFR 236.779 - Plate, top.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Plate, top. 236.779 Section 236.779 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF... OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.779 Plate, top....

  12. 49 CFR 236.779 - Plate, top.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Plate, top. 236.779 Section 236.779 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF... OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.779 Plate, top....

  13. 49 CFR 236.779 - Plate, top.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Plate, top. 236.779 Section 236.779 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF... OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Definitions § 236.779 Plate, top....

  14. Overview of the multilayer-Fresnel zone plate and the kinoform lens development at MPI for intelligent systems

    NASA Astrophysics Data System (ADS)

    Tunca Sanli, Umut; Keskinbora, Kahraman; Grévent, Corinne; Schütz, Gisela

    2015-05-01

    The ultimate goal of our research is to develop novel fabrication methods for high efficiency and high resolution X-ray optics. To this end, we have been pursuing the fabrication of several innovative diffractive/refractive optics designs. One such optic is the multilayer type Fresnel zone plate (ML-FZP). Our fabrication process relies on the atomic layer deposition (ALD) of two materials on a smooth glass fiber followed by a focused ion beam (FIB) based slicing and polishing. The ALD process allows much smaller outermost zone widths than the standard electron beam lithography based FZPs, meaning FZPs with potentially higher resolutions. Moreover, by depositing the multilayer on a cm long glass-fiber FZPs with very high optical thicknesses can be fabricated that can efficiently focus harder X-rays as well. A 21 nm half-pitch resolution was achieved using the ML-FZPs. Another optic we have been working on is the kinoform lens, which is a refractive/diffractive optic with a 100 % theoretical focusing efficiency. Their fabrication is usually realized by using approximate models which limit their success. Recently the fabrication of real kinoform lenses has been successfully realized in our lab via gray-scale direct-write ion beam lithography without any approximations. The lenses have been tested in the soft X-ray range achieving up to ~90 % of the calculated efficiency which indicates outstanding replication of the designed profile. Here we give an overview of our research and discuss the future challenges and opportunities for these optics.

  15. Deciphering the mechanics of an imaged fault system in the over-riding plate at the Shumagin Seismic Gap, Alaska subduction zone using MCS waveform tomography

    NASA Astrophysics Data System (ADS)

    Michaelson, C. A.; Delescluse, M.; Becel, A.; Nedimovic, M. R.; Shillington, D. J.; Louden, K. E.; Webb, S. C.

    2013-12-01

    The 2011 ALEUT program acquired 3500 km of multichannel seismic (MCS) data along a part of the western Alaska subduction zone, from the freely slipping Shumagin Seismic Gap to the locked regions in the Semidi segment and the western Kodiak asperity. The MCS profiles were acquired on the R/V Langseth using two 8-km-long streamers and span the entire locked zone on the megathrust, including the updip and downdip transitions to stable sliding. The primary goal was to characterize variations in the geometry and properties of the megathrust and the downgoing plate and relate them to downdip and along-strike changes in slip behavior and seismogenesis. The images capture the targeted megathrust reflectivity and its spatial variation. Notably, the two westernmost profiles show reflections arising from a major fault in the overriding plate within the Shumagin Seismic Gap located 75 km from the trench, which can be followed from the seafloor to the megathrust. The imaged normal fault bounds the seaward end of the Sanak forearc Cenozoic basin, formed after the Early Eocene reorganization of the Alaska subduction zone. The new reflection images also show that the seaward pair of the previously interpreted growth faults, thought to indicate deposition contemporaneous with basin subsidence, is a part of the imaged fault system. The unexpected imaging of this major fault system in the over-riding plate raises important questions: Has this fault been active during the most recent nearby megathrust earthquakes, such as the 1946 and 1948 earthquakes? Was the Sanak basin formed as a result of slip on the imaged normal fault system or is it a result of growth faulting that predates the formation of this fault? The timing and style of deformation on this fault has significant implications for both coupling on the megathrust seaward and landward of where the normal fault roots and tsunamigenesis. To complement constraints on the geometry and reflection characteristics of this structure

  16. A sensitivity analysis of central flat-plate photovoltaic systems and implications for national photovoltaics program planning

    NASA Technical Reports Server (NTRS)

    Crosetti, M. R.

    1985-01-01

    The sensitivity of the National Photovoltaic Research Program goals to changes in individual photovoltaic system parameters is explored. Using the relationship between lifetime cost and system performance parameters, tests were made to see how overall photovoltaic system energy costs are affected by changes in the goals set for module cost and efficiency, system component costs and efficiencies, operation and maintenance costs, and indirect costs. The results are presented in tables and figures for easy reference.

  17. Optics for People Stuck in Traffic: License Plates.

    ERIC Educational Resources Information Center

    Chagnon, Paul

    1995-01-01

    Explains the theory behind the working of Scotchlite, a retrodirective material used for coating automotive license plates, and the Ensure Imaging System that allows law enforcement officers to verify the authenticity of the plate. (JRH)

  18. A Simple Class Exercise on Plate Tectonic Motion.

    ERIC Educational Resources Information Center

    Bates, Denis E. B.

    1990-01-01

    Presented is an activity in which students construct a model of plate divergence with two sheets of paper to show the separation of two continental plates in a system of spreading ridges and faults. Diagrams and procedures are described. (CW)

  19. WFPDB: European Plate Archives

    NASA Astrophysics Data System (ADS)

    Tsvetkov, Milcho

    2007-08-01

    The Wide-Field Plate Database (WFPDB) gives an inventory of all wide-field (>~ 1 sq. deg) photographic observations archived in astronomical institutions over the world. So it facilitates and stimulates their use and preservation as a valuable source of information for future investigations in astronomy. At present WFPDB manages plate-index information for 25% of all existing plates providing on-line access from Sofia (http://www.skyarchive.org/search) and in CDS, Strasbourg. Here we present the new development of WFPDB as an instrument for searching of long term brightness variations of different sky objects stressing on the European photographic plate collections (from existing 2 million wide-field plates more than 55% are in Europe: Germany, Russia, Ukraine, Italy, Czech Republic, etc.). We comment examples of digitization (with flatbed scanners) of the European plate archives in Sonneberg, Pulkovo, Asiago, Byurakan, Bamberg, etc. and virtual links of WFPDB with European AVO, ADS, IBVS.

  20. Inherent Strength of the osteo-WEDGE(™) Bone Plate Locking System for Arthrodesis of the First Metatarsocuneiform Joint: A Biomechanical Study.

    PubMed

    Graham, Michael E; Chikka, Avanthi; Goel, Vijay K

    2016-01-01

    First metatarsocuneiform joint arthrodesis with a locking bone plate and screw system has been effectively used to correct metatarsus primus varus and instability of the first ray. The goal of the present cadaveric biomechanical study was to quantify and compare the inherent strength of the first metatarsocuneiform joint and surrounding bones fixated with the osteo-WEDGE(™) bone plate locking system (OW) with that of intact specimens. Fourteen fresh-frozen adult human cadaveric foot specimens consisting of the first metatarsal and medial cuneiform bones with intact joint capsules and ligaments were used. The OW was implanted in 7 of these specimens at the first metatarsal cuneiform joint (MCJ), and the remaining 7 specimens were left intact. Each of the specimens was then subjected to axial force to simulate dorsiflexion of the first metatarsal using a cantilever bending test setup. Load was applied on the plantar aspect of the first metatarsal head until failure of the construct. The mean load and bending moment on the first MCJ at failure for the implanted specimens were 119.98 ± 56.76 N and 5.57 ± 2.71 Nm, respectively. For the intact specimens, the mean load and bending moment on the first MCJ at failure were 107.93 ± 60.90 N and 6.07 ± 3.18 Nm, respectively. None of the specimens showed catastrophic failure within the physiologic loading limits. These results imply that the mechanical strength of the OW is comparable to that of intact specimens. Thus, the first MCJ and surrounding bones fixated with an OW should be able to effectively withstand the vertical ground reaction forces the same as intact specimens. PMID:26884262

  1. GOLD PLATING PROCESS

    DOEpatents

    Seegmiller, R.

    1957-08-01

    An improved bath is reported for plating gold on other metals. The composition of the plating bath is as follows: Gold cyanide from about 15 to about 50 grams, potassium cyanide from about 70 to about 125 grams, and sulfonated castor oil from about 0.1 to about 10 cc. The gold plate produced from this bath is smooth, semi-hard, and nonporous.

  2. Plating methods, a survey

    NASA Technical Reports Server (NTRS)

    Berkowitz, J. B.; Emerson, N. H.

    1972-01-01

    Results are presented of a comprehensive search of the literature available, much of which has been generated by the research centers of NASA and its contractors, on plating and coating methods and techniques. Methods covered included: (1) electroplating from aqueous solutions; (2) electroplating from nonaqueous solutions; (3) electroplating from fused-salt baths; (4) electroforming; (5) electroless plating, immersion plating, and mirroring; (6) electroplating from gaseous plasmas; and (7) anodized films and conversion coatings.

  3. Vibration of thin, tensioned, helically wrapped plates

    NASA Astrophysics Data System (ADS)

    Lopez, Ernesto; Müftü, Sinan

    2011-02-01

    Free vibration analysis of a thin tensioned plate, wrapped around a cylindrical guide in a helical manner is presented. The system is a model of a thin, flexible web wrapped around a turn-bar. The equation of motion of the wrapped plate is derived by using the energy method and with the Kirchhoff-Love assumptions. The weak form of the equation of motion was obtained by the finite element method and the eigenvalue problem was solved numerically. The effects of parameters such as plate tension, guide radius, longitudinal and helical wrap angles, plate width, and the lengths of the non-wrapped segments were investigated. Eigenmodes with same mode numbers were observed in symmetric and anti-symmetric fashion about the center of the plate, for symmetrically wrapped plates. It was shown that the plate/shell boundary of the wrapped plate effectively acts like a support. For non-helically wrapped plates the free edges cause a frequency clustering of the lateral modes about the dominant longitudinal mode. The frequency clustering diminishes when helical wrap is introduced.

  4. CALUTRON FACE PLATE

    DOEpatents

    Brobeck, W.M.

    1959-08-25

    The construction of a removable cover plate for a calutron tank is described. The plate is fabricated of a rectangular frame member to which is welded a bowed or dished plate of thin steel, reinforced with transverse stiffening ribs. When the tank is placed between the poles of a magnet, the plate may be pivoted away from the tank and magnet and is adapted to support the ion separation mechanism secured to its inner side as well as the vacuum load within the tank.

  5. PLATES WITH OXIDE INSERTS

    DOEpatents

    West, J.M.; Schumar, J.F.

    1958-06-10

    Planar-type fuel assemblies for nuclear reactors are described, particularly those comprising fuel in the oxide form such as thoria and urania. The fuel assembly consists of a plurality of parallel spaced fuel plate mennbers having their longitudinal side edges attached to two parallel supporting side plates, thereby providing coolant flow channels between the opposite faces of adjacent fuel plates. The fuel plates are comprised of a plurality of longitudinally extending tubular sections connected by web portions, the tubular sections being filled with a plurality of pellets of the fuel material and the pellets being thermally bonded to the inside of the tubular section by lead.

  6. Shock wave absorber having apertured plate

    DOEpatents

    Shin, Yong W.; Wiedermann, Arne H.; Ockert, Carl E.

    1985-01-01

    The shock or energy absorber disclosed herein utilizes an apertured plate maintained under the normal level of liquid flowing in a piping system and disposed between the normal liquid flow path and a cavity pressurized with a compressible gas. The degree of openness (or porosity) of the plate is between 0.01 and 0.60. The energy level of a shock wave travelling down the piping system thus is dissipated by some of the liquid being jetted through the apertured plate toward the cavity. The cavity is large compared to the quantity of liquid jetted through the apertured plate, so there is little change in its volume. The porosity of the apertured plate influences the percentage of energy absorbed.

  7. Shock wave absorber having apertured plate

    DOEpatents

    Shin, Y.W.; Wiedermann, A.H.; Ockert, C.E.

    1983-08-26

    The shock or energy absorber disclosed herein utilizes an apertured plate maintained under the normal level of liquid flowing in a piping system and disposed between the normal liquid flow path and a cavity pressurized with a compressible gas. The degree of openness (or porosity) of the plate is between 0.01 and 0.60. The energy level of a shock wave travelling down the piping system thus is dissipated by some of the liquid being jetted through the apertured plate toward the cavity. The cavity is large compared to the quantity of liquid jetted through the apertured plate, so there is little change in its volume. The porosity of the apertured plate influences the percentage of energy absorbed.

  8. Alteration of the aPA ELISA by UV exposure of polystyrene microtiter plates.

    PubMed

    Goldberg, J S; Wagenknecht, D R; McIntyre, J A

    1996-01-01

    Interlaboratory inconsistencies in antiphospholipid antibody (aPA) solid phase assays have prompted controversy in clinical laboratory testing for aPA. We found that the aPA ELISA can be influenced by the type of microtiter plate utilized and by the conditions in which the plates are stored. By exposing 96-well, flat-bottom polystyrene microtiter plates to short wave UV light (254 nm), the aPA ELISA signal decreased in a UV dose-dependent manner. No effect was seen with long wave UV light (366 nm). These results were independent of the antibody isotype under study or the phospholipid (PL) antigen used: anionic phosphatidylserine (PS) and cardiolipin (CL), or zwitterionic phosphatidylethanolamine (PE). Purified human beta 2-glycoprotein I (beta 2 GPI), a known cofactor for anionic PL, and rabbit anti-beta 2 GPI antisera were used to demonstrate that beta 2 GPI bound equally to UV treated and untreated microtiter plates. In contrast, recognition of beta 2 GPI on an anionic PL surface was decreased on UV treated plates, suggesting that UV exposure alters the lipid binding properties of the microliter plate. To determine whether UV exposure inhibited PL binding directly or caused a change in the way the PL was bound, the amount of PL bound to UV treated and untreated plates was measured by using fluorescent labeled PS and a fluorimeter. PS binding was decreased by 53% in UV treated wells as compared to untreated wells. These data show that short wave UV exposure reduces PL binding to polystyrene microtiter plates, thereby reducing the amount of beta 2 GPI bound to PL coated ELISA plates. Thus by using UV exposed microtiter plates, decreased or false-negative a PA ELISA results may be obtained for aPA positive plasmas. PMID:8887002

  9. Exhumation History of an Oblique Plate Boundary: Investigating Kaikoura Mountain-building within the Marlborough Fault System, NE South Island New Zealand

    NASA Astrophysics Data System (ADS)

    Collett, C.; Duvall, A. R.; Flowers, R. M.; Tucker, G. E.

    2015-12-01

    The Kaikoura Mountains stand high as topographic anomalies in the oblique Pacific-Australian plate boundary zone known as the Marlborough Fault System (MFS), NE South Island New Zealand. The base of both the Inland and Seaward Kaikoura Ranges are bound on the SE by major, steeply NW-dipping, right lateral, active strike-slips (Clarence and Hope faults of the MFS, respectively). Previous geologic mapping, observations of predominantly horizontal fault slip at the surface from GPS and offset Quaternary deposits, and uplift of marine terraces, provide evidence for shortening and mountain-building via distributed deformation off of the main MFS strike-slip faults. However, quantitative estimates of the magnitude and spatial patterns of exhumation and of the timing of mountain-building in the Kaikouras are needed to understand more fully the nature of oblique deformation in the MFS. We present new apatite and zircon (U-Th)/He ages from opposite sides of the Hope and Clarence faults, spanning over 2 km of relief within the Kaikoura Mountains to identify spatial and temporal changes in exhumation rates in relation to the adjacent faults. Young (~3 Ma) apatite He ages and rapid (potentially > 1 mm/yr) exhumation rates from opposite sides of the faults are consistent with previously mentioned evidence of recent, regional, distributed deformation off of the main MFS faults. Moreover, early Miocene zircon He ages imply that parts of this region experienced an earlier phase of fault-related exhumation. Large changes in zircon He ages across the faults from ~20 Ma to > 100 Ma support hypotheses that portions of the Marlborough Faults may be re-activated, early Miocene thrusts. The zircon data are also consistent with the hypothesis of an early Miocene initiation of the oblique Pacific-Australian plate boundary in this region. Evidence for this comes from a change in sedimentation during this time from fine marine sediments to coarse, terrigenous conglomerates. Observing more

  10. Unsteady two-layered fluid flow of conducting fluids in a channel between parallel porous plates under transverse magnetic field in a rotating system

    NASA Astrophysics Data System (ADS)

    Linga Raju, T.; Neela Rao, B.

    2016-05-01

    An unsteady MHD two-layered fluid flow of electrically conducting fluids in a horizontal channel bounded by two parallel porous plates under the influence of a transversely applied uniform strong magnetic field in a rotating system is analyzed. The flow is driven by a common constant pressure gradient in a channel bounded by two parallel porous plates, one being stationary and the other oscillatory. The two fluids are assumed to be incompressible, electrically conducting with different viscosities and electrical conductivities. The governing partial differential equations are reduced to the linear ordinary differential equations using two-term series. The resulting equations are solved analytically to obtain exact solutions for the velocity distributions (primary and secondary) in the two regions respectively, by assuming their solutions as a combination of both the steady state and time dependent components of the solutions. Numerical values of the velocity distributions are computed for different sets of values of the governing parameters involved in the study and their corresponding profiles are also plotted. The details of the flow characteristics and their dependence on the governing parameters involved, such as the Hartmann number, Taylor number, porous parameter, ratio of the viscosities, electrical conductivities and heights are discussed. Also an observation is made how the velocity distributions vary with the rotating hydromagnetic interaction in the case of steady and unsteady flow motions. The primary velocity distributions in the two regions are seen to decrease with an increase in the Taylor number, but an increase in the Taylor number causes a rise in secondary velocity distributions. It is found that an increase in the porous parameter decreases both the primary and secondary velocity distributions in the two regions.

  11. Simultaneous runs of the Bayer VERSANT HIV-1 version 3.0 and HCV bDNA version 3.0 quantitative assays on the system 340 platform provide reliable quantitation and improved work flow.

    PubMed

    Elbeik, Tarek; Markowitz, Norman; Nassos, Patricia; Kumar, Uday; Beringer, Scott; Haller, Barbara; Ng, Valerie

    2004-07-01

    Branched DNA (bDNA) assays to quantify human immunodeficiency virus type 1 (HIV-1) and hepatitis C virus (HCV) consist of three distinct steps, including sample processing, hybridization, and detection, and utilize the System 340 platform for plate incubation and washing. Sample processing differs: HIV-1 from 1 ml of plasma is concentrated by high-speed centrifugation, whereas HCV plasma or serum samples are used without concentration. The first step of hybridization involves viral lysis at 63 degrees C: HIV-1 is performed in a heat block, whereas HCV is performed in System 340. The remaining hybridization and detection steps are similar for HIV-1 and HCV and executed on System 340. In the present study, the HIV-1 bDNA assay was adapted for viral lysis in the System 340 platform. The adaptation, test method 2, includes a 20-s vortex of concentrated viral pellet and lysis working solution, transfer of viral lysate to the 96-well capture plate, and transfer to System 340 programmed for HCV assay specifications. With test method 2, specificity and quantification were within assay specifications. HCV bDNA methodology remains unchanged. Hence, an HIV-1 and an HCV bDNA can be run simultaneously on System 340. With simultaneous testing, laboratories can run full plates, as well as combinations of full and partial plates. Also, simultaneous HIV-1 and HCV bDNA permits labor consolidation and improved workflow while maintaining multitasking and rapid patient result turnaround. PMID:15243070

  12. Blue Willow Story Plates

    ERIC Educational Resources Information Center

    Fontes, Kris

    2009-01-01

    In the December 1997 issue of "SchoolArts" is a lesson titled "Blue Willow Story Plates" by Susan Striker. In this article, the author shares how she used this lesson with her middle-school students many times over the years. Here, she describes a Blue Willow plate painting project that her students made.

  13. Earthquakes and plate tectonics

    USGS Publications Warehouse

    Spall, H.

    1977-01-01

    An explanation is to be found in plate tectonics, a concept which has revolutionized thinking in the Earth sciences in the last 10 years. The theory of plate tectonics combines many of the ideas about continental drift (originally proposed in 1912 by Alfred Wegener in Germany) and sea-floor spreading (suggested originally by Harry Hess of Princeton University). 

  14. A new control and data acquisition system for cosmic ray telescopes based on multigap resistive plate chambers

    NASA Astrophysics Data System (ADS)

    Avanzini, C.; Bossini, E.; Paoletti, R.; Partini, S.; Pilo, F.; Tazzioli, A.

    2013-08-01

    The upcoming phase of expansion of the telescope network of the EEE project has recently inspired a proposal of redesign of the detector control and monitoring, as well as data acquisition interfaces. The new design results in a very compact and versatile system with a significant cost reduction. The system architecture is described, with emphasis on the integration of data acquisition, trigger and GPS into a single unit. Performances of a fully functional prototype are also reported, as well as plans for future developments.

  15. Turbine vane plate assembly

    DOEpatents

    Schiavo Jr., Anthony L.

    2006-01-10

    A turbine vane assembly includes a turbine vane having first and second shrouds with an elongated airfoil extending between. Each end of the airfoil transitions into a shroud at a respective junction. Each of the shrouds has a plurality of cooling passages, and the airfoil has a plurality of cooling passages extending between the first and second shrouds. A substantially flat inner plate and an outer plate are coupled to each of the first and second shrouds so as to form inner and outer plenums. Each inner plenum is defined between at least the junction and the substantially flat inner plate; each outer plenum is defined between at least the substantially flat inner plate and the outer plate. Each inner plenum is in fluid communication with a respective outer plenum through at least one of the cooling passages in the respective shroud.

  16. Importance of the Small-Scale Processes Melting, Plate Boundary Formation and Mineralogy on the Large-Scale, Long-Term Thermo-Chemical Evolution of Earth's Mantle-Plate System

    NASA Astrophysics Data System (ADS)

    Tackley, P.

    2015-12-01

    Seismic observations of the deep Earth reveal the presence of two large low shear velocity provinces (LLSVPs) that are typically inferred to be dense chemically-distinct material, as well as discontinuities that are typically linked to the post-perovskite (pPv) phase transition. Several possible origins of chemically-dense material have been proposed, including recycling of mid-ocean ridge basalt (MORB), primordial differentiation events, crystallisation of a basal magma ocean, or some combination of these creating a basal melange (BAM; Tackley 2012 Earth Sci. Rev.). Each of these possibilities would result in a different composition hence different mineralogy. In order to constrain this we have been running calculations of thermo-chemical mantle evolution over 4.5 billion years that include melting-induced differentiation, plate tectonics induced by strongly temperature-dependent viscosity and plastic yielding, core cooling and compressibility with reasonable assumptions about the pressure-dependence of other material properties. Some of our simulations start from a magma ocean state so initial layering is developed self-consistently. Already-published results (Nakagawa et al., 2009 GCubed, 2010 PEPI, 2012 GCubed) already indicate the importance of exact MORB composition on the amount of MORB segregating above the CMB, which in turn influences mantle thermal structure and the evolution of the core and geodynamo. In more recent results we have been additionally including primordial material. We find that melting-induced differentiation has several first-order effects on the dynamics, including (i) making plate tectonics easier (through stresses associated with lateral variations in crustal thickness) and (ii) reducing heat flux through the CMB (due to the build-up of dense material above the CMB); also (iii) tectonic mode (continuous plate tectonics, episodic lid or stagnant lid) also makes a first-order difference to mantle structure and dynamics. This emphasises

  17. Integrated light-guide plates that can control the illumination angle for liquid crystal display backlight system

    NASA Astrophysics Data System (ADS)

    Feng, Di; Yang, Xingpeng; Jin, Guofan; Yan, Yingbai; Fan, Shoushan

    2006-01-01

    Liquid crystal displays (LCDs) with edge-lit backlight systems offer several advantages, such as low energy consuming, low weight, and high uniformity of intensity, over traditional cathode-ray tube displays, and make them ideal for many applications including monitors in notebook personal computers, screens for TV, and many portable information terminals, such as mobile phones, personal digital assistants, etc. To satisfy market requirements for mobile and personal display panels, it is more and more necessary to modify the backlight system and make it thinner, lighter, and brighter all at once. In this paper, we have proposed a new integrated LGP based on periodic and aperiodic microprism structures by using polymethyl methacrylate material, which can be designed to control the illumination angle, and to get high uniformity of intensity. So the backlight system will be simplified to use only light sources and one LGP without using other optical sheets, such as reflection sheet, diffusion sheet and prism sheets. By using optimizing program and ray tracing method, the designed LGPs can achieve a uniformity of intensity better than 86%, and get a peak illumination angle from +400 to -200, without requiring other optical sheets. We have designed a backlight system with only one LED light source and one LGP, and other LGP design examples with different sizes (1.8 inches and 14.1 inches) and different light source (LED or CCFL), are performed also.

  18. 4-D Subduction Models Incorporating an Upper Plate

    NASA Astrophysics Data System (ADS)

    Stegman, D.; Capitanio, F. A.; Moresi, L.; Mueller, D.; Clark, S.

    2007-12-01

    Thus far, relatively simplistic models of free subduction have been employed in which the trench and plate kinematics are emergent features completely driven by the negative buoyancy of the slab. This has allowed us to build a fundamental understanding of subduction processes such as the kinematics of subduction zones, the strength of slabs, and mantle flow-plate coupling. Additionaly, these efforts have helped to develop appreciable insight into subduction processes when considering the energetics of subduction, in particular how energy is dissipated in various parts of the system such as generating mantle flow and bending the plate. We are now in a position to build upon this knowledge and shift our focus towards the dynamic controls of deformation in the upper plate (vertical motions, extension, shortening, and dynamic topography). Here, the state of stress in the overriding plate is the product of the delicate balance of large tectonic forces in a highly-coupled system, and must therefore include all components of the system: the subducting plate, the overriding plate, and the underlying mantle flow which couples everything together. We will present some initial results of the fully dynamic 3-D models of free subduction which incorporate an overriding plate and systematically investigate how variations in the style and strength of subduction are expressed by the tectonics of the overriding plate. Deformation is driven in the overriding plate by the forces generated from the subducting plate and the type of boundary condition on the non-subducting side of the overriding plate (either fixed or free). Ultimately, these new models will help to address a range of issues: how the overriding plate influences the plate and trench kinematics; the formation and evolution of back-arc basins; the variation of tractions on the base of the overriding plate; the nature of forces which drive plates; and the dynamics controls on seismic coupling at the plate boundary.

  19. Stress orientations in northern and central California: Evidence for the evolution of frictional strength along the San Andreas plate boundary system

    NASA Astrophysics Data System (ADS)

    Provost, Ann-Sophie; Houston, Heidi

    2003-03-01

    We determined orientations of principal stresses around the San Andreas fault (SAF) system in the greater San Francisco Bay Area and regions farther north along the strike-slip plate boundary. Stress orientations, as well as a ratio between principal stress magnitudes, were determined by inversions of ˜6000 earthquake fault plane solutions, divided into ˜100 groups based on the spatial distribution of seismicity with respect to major regional fault strands (i.e., the SAF, the Hayward-Rodgers Creek-Maacama fault zone, and the Calaveras-Green Valley-Bartlett Springs fault zone). The stress orientations, while spatially variable, reveal several features; to describe them, it is useful to distinguish between groups of events occurring on and off the major fault strands. First, for off-fault groups, the angle between major fault strands and the maximum horizontal compression SH decreases systematically to the north. This contrasts with the high angles of SH (˜80°) found immediately adjacent to, as well as farther from, the creeping segment of the SAF in central California by [2001]. Second, for on-fault groups, the angle that SH makes with major fault strands changes little along strike, averaging 50° to 55° in the creeping segment, the Bay area, and the northernmost part of our study area. Third, as in the vicinity of the creeping segment of the SAF in central California, the majority of both the off-fault groups, and the on-fault groups, are in a strike-slip, rather than thrust, tectonic regime. Finally, anomalous east-west SH orientations are seen in the vicinity of Sutter Buttes. In the north, multiple strands of the strike-slip fault system have accumulated little slip, dip relatively shallowly and are composed of short, complex en échelon segments, suggesting that they originated as thrust faults in the accretionary prism associated with the Farallon subduction and have been subsequently reactivated in a strike-slip sense following the northward passage of

  20. Twenty-four well plate miniature bioreactor system as a scale-down model for cell culture process development.

    PubMed

    Chen, Aaron; Chitta, Rajesh; Chang, David; Amanullah, Ashraf

    2009-01-01

    Increasing the throughput and efficiency of cell culture process development has become increasingly important to rapidly screen and optimize cell culture media and process parameters. This study describes the application of a miniaturized bioreactor system as a scaled-down model for cell culture process development using a CHO cell line expressing a recombinant protein. The microbioreactor system (M24) provides non-invasive online monitoring and control capability for process parameters such as pH, dissolved oxygen (DO), and temperature at the individual well level. A systematic evaluation of the M24 for cell culture process applications was successfully completed. Several challenges were initially identified. These included uneven gas distribution in the wells due to system design and lot to lot variability, foaming issues caused by sparging required for active DO control, and pH control limitation under conditions of minimal dissolved CO2. A high degree of variability was found which was addressed by changes in the system design. The foaming issue was resolved by addition of anti-foam, reduction of sparge rate, and elimination of DO control. The pH control limitation was overcome by a single manual liquid base addition. Intra-well reproducibility, as indicated by measurements of process parameters, cell growth, metabolite profiles, protein titer, protein quality, and scale-equivalency between the M24 and 2 L bioreactor cultures were very good. This evaluation has shown feasibility of utilizing the M24 as a scale-down tool for cell culture application development under industrially relevant process conditions. PMID:18683260

  1. The Effects of Ni-Plating and Prolonged High Temperature Oxidation at 1423 K (1150 °C) on a CMSX-10 Single-Crystal Ni-Based Super-Alloy and Coating System

    NASA Astrophysics Data System (ADS)

    Clancy, Marie; Pomeroy, Michael J.

    2013-07-01

    A hypothesis was investigated, to assess if Ni-plating a 3rd-generation single-crystal alloy could favorably alter the diffusion profile of critical elements such that brittle, deleterious topologically close-packed (TCP) phases did not form or at least the extent to which they did was reduced. In conjunction with delaying the onset of these phases, it was hoped that more favorable alternatives could be promoted, such as martensite (β'). This study showed that Ni-plating did have some positive effects on the super-alloy/coating system. While the coating produced on the Ni-plated alloy was thinner, it retained a higher Al content than its unplated counterpart when subjected to oxidation. The retention of Al within the coating delayed the phase evolution of the coating from a β or β + β' to a γ'-dominant coating as the Ni-plated system had a greater driving force for Ni and Al diffusion, which helped to establish the Ni-rich diffusion barrier that entrapped Al in the coating. Unfortunately, Ni-plating does not sufficiently alter the diffusion profiles within the alloy to prevent precipitation of the TCP phases. Four pairs of the CMSX-10 alloy were used for this study. While they were all aluminized, only half of them, one in each pair, were Ni plated prior to aluminizing. Three of the four pairs were then oxidized at 1423 K (1150 °C), while the first pair was kept as a standard. X-ray diffraction, scanning electron microscopy, and energy dispersive X-ray spectroscopy were used to characterize each alloy-coating system in an effort to better understand their performance under high temperature oxidation.

  2. Vacuum fusion bonding of glass plates

    DOEpatents

    Swierkowski, Steve P.; Davidson, James C.; Balch, Joseph W.

    2000-01-01

    An improved apparatus and method for vacuum fusion bonding of large, patterned glass plates. One or both glass plates are patterned with etched features such as microstructure capillaries and a vacuum pumpout moat, with one plate having at least one hole therethrough for communication with a vacuum pumpout fixture. High accuracy alignment of the plates is accomplished by a temporary clamping fixture until the start of the fusion bonding heat cycle. A complete, void-free fusion bond of seamless, full-strength quality is obtained through the plates; because the glass is heated well into its softening point and because of a large, distributed force that is developed that presses the two plates together from the difference in pressure between the furnace ambient (high pressure) and the channeling and microstructures in the plates (low pressure) due to the vacuum drawn. The apparatus and method may be used to fabricate microcapillary arrays for chemical electrophoresis; for example, any apparatus using a network of microfluidic channels embedded between plates of glass or similar moderate melting point substrates with a gradual softening point curve, or for assembly of glass-based substrates onto larger substrates, such as in flat panel display systems.

  3. Vacuum fusion bonding of glass plates

    DOEpatents

    Swierkowski, Steve P.; Davidson, James C.; Balch, Joseph W.

    2001-01-01

    An improved apparatus and method for vacuum fusion bonding of large, patterned glass plates. One or both glass plates are patterned with etched features such as microstructure capillaries and a vacuum pumpout moat, with one plate having at least one hole therethrough for communication with a vacuum pumpout fixture. High accuracy alignment of the plates is accomplished by a temporary clamping fixture until the start of the fusion bonding heat cycle. A complete, void-free fusion bond of seamless, full-strength quality is obtained through the plates; because the glass is heated well into its softening point and because of a large, distributed force that is developed that presses the two plates together from the difference in pressure between the furnace ambient (high pressure) and the channeling and microstructures in the plates (low pressure) due to the vacuum drawn. The apparatus and method may be used to fabricate microcapillary arrays for chemical electrophoresis; for example, any apparatus using a network of microfluidic channels embedded between plates of glass or similar moderate melting point substrates with a gradual softening point curve, or for assembly of glass-based substrates onto larger substrates, such as in flat panel display systems.

  4. Analysis of hydraulic instability of ANS involute fuel plates

    SciTech Connect

    Sartory, W.K.

    1991-11-01

    Curved shell equations for the involute Advanced Neutron Source (ANS) fuel plates are coupled to two-dimensional hydraulic channel flow equations that include fluid friction. A complete set of fluid and plate boundary conditions is applied at the entrance and exit and along the sides of the plate and the channel. The coupled system is linearized and solved to assess the hydraulic instability of the plates.

  5. Earthquakes and plate tectonics.

    USGS Publications Warehouse

    Spall, H.

    1982-01-01

    Earthquakes occur at the following three kinds of plate boundary: ocean ridges where the plates are pulled apart, margins where the plates scrape past one another, and margins where one plate is thrust under the other. Thus, we can predict the general regions on the earth's surface where we can expect large earthquakes in the future. We know that each year about 140 earthquakes of magnitude 6 or greater will occur within this area which is 10% of the earth's surface. But on a worldwide basis we cannot say with much accuracy when these events will occur. The reason is that the processes in plate tectonics have been going on for millions of years. Averaged over this interval, plate motions amount to several mm per year. But at any instant in geologic time, for example the year 1982, we do not know, exactly where we are in the worldwide cycle of strain build-up and strain release. Only by monitoring the stress and strain in small areas, for instance, the San Andreas fault, in great detail can we hope to predict when renewed activity in that part of the plate tectonics arena is likely to take place. -from Author

  6. Lohse's historic plate archive

    NASA Astrophysics Data System (ADS)

    Tsvetkov, M.; Tsvetkova, K.; Richter, G.; Scholz, G.; Böhm, P.

    The description and the analysis of Oswald Lohse's astrophotographic plates, collected at the Astrophysical Observatory Potsdam in the period 1879 - 1889, are presented. 67 plates of the archive, taken with the greatest instrument of the observatory at that time - the refractor (D = 0.30 m, F = 5.40 m, scale = 38''/mm) and with the second heliographic objective (D = 0.13 m, F = 1.36 m, scale = 152''/mm) - - survived two world wars in relative good condition. The plate emulsions are from different manufacturers in the beginning of astrophotography (Gädicke, Schleussner, Beernaert, etc.). The sizes of the plates are usually 9x12 cm2, which corresponds to fields of 1.2deg and 5deg respectively for each instrument mentioned above. The average limiting magnitude is 13.0(pg). Besides of the plates received for technical experiments (work on photographic processes, testing of new instruments and methods of observations), the scientific observations follow programs for studies of planet surfaces, bright stars, some double stars, stellar clusters and nebulous objects. Lohse's archive is included into the Wide Field Plate Database (http://www.skyarchive.org) as the oldest systematic one, covering the fields of Orion (M42/43), Pleiades, h & chi Persei, M37, M3, M11, M13, M92, M31, etc. With the PDS 2020 GM+ microdensitometer of Münster University 10 archive plates were digitized.

  7. Three-thrust fault system at the plate suture of arc-continent collision in the southernmost Longitudinal Valley, eastern Taiwan

    NASA Astrophysics Data System (ADS)

    Lee, J.; Chen, H.; Hsu, Y.; Yu, S.

    2013-12-01

    Active faults developed into a rather complex three-thrust fault system at the southern end of the narrow Longitudinal Valley in eastern Taiwan, a present-day on-land plate suture between the Philippine Sea plate and Eurasia. Based on more than ten years long geodetic data (including GPS and levelling), field geological investigation, seismological data, and regional tomography, this paper aims at elucidating the architecture of this three-thrust system and the associated surface deformation, as well as providing insights on fault kinematics, slip behaviors and implications of regional tectonics. Combining the results of interseismic (secular) horizontal and vertical velocities, we are able to map the surface traces of the three active faults in the Taitung area. The west-verging Longitudinal Valley Fault (LVF), along which the Coastal Range of the northern Luzon arc is thrusting over the Central Range of the Chinese continental margin, braches into two active strands bounding both sides of an uplifted, folded Quaternary fluvial deposits (Peinanshan massif) within the valley: the Lichi fault to the east and the Luyeh fault to the west. Both faults are creeping, to some extent, in the shallow surface level. However, while the Luyeh fault shows nearly pure thrust type, the Lichi fault reveals transpression regime in the north and transtension in the south end of the LVF in the Taitung plain. The results suggest that the deformation in the southern end of the Longitudinal Valley corresponds to a transition zone from present arc-collision to pre-collision zone in the offshore SE Taiwan. Concerning the Central Range, the third major fault in the area, the secular velocities indicate that the fault is mostly locked during the interseismic period and the accumulated strain would be able to produce a moderate earthquake, such as the example of the 2006 M6.1 Peinan earthquake, expressed by an oblique thrust (verging toward east) with significant left-lateral strike slip

  8. Tectonic development of the SW Arabian Plate margin within the central Arabian flank of the Red Sea rift system

    NASA Astrophysics Data System (ADS)

    Szymanski, E.; Stockli, D. F.; Johnson, P. R.; Kattan, F. H.; Cosca, M. A.

    2009-12-01

    The Red Sea rift system is a prime example of continental rifting and has contributed significantly to our understanding of the geologic processes that manage the rupture of continental lithosphere. Using a combined geo- and thermochronometric approach, we explore the modes and mechanisms of rift margin development by studying Red Sea rift-related geologic products along the central Saudi Arabian flank of the rift system, north of Jeddah. We use apatite and zircon (U-Th)/He thermochronometry and whole-rock 40Ar/39Ar dating of basalt to define the spatiotemporal relationship between rift flank extensional structures and rift-related harrat volcanism. This technical approach permits the reconstruction of the tectonic margin from early rift architecture, to strain distribution during progressive rifting, and through subsequent whole-scale modifications of the rift flank due to thermal and isostatic factors. Constraints on the dynamics of rift flank deformation are achieved through the collection of geologic samples along long-baseline thermochronometric transects that traverse the entire Arabian shield from the coastal escarpment to the inland Paleozoic sedimentary cover sequences. Long-baseline transects resolve the timing of rift flank uplift and reveal the pattern of lithospheric modification during the rupturing of continental lithosphere. Locally, short-baseline elevation transects map the footwall exhumation of major normal faults that delineate both the modern rift margin and inland extensional basins such as the NW-trending Hamd-Jizil basin, a prominent syn-extensional basin comprised of two distinct half-grabens (Jizil and Hamd) located NW of Medina. Diffuse lithospheric extension during the Oligo-Miocene affected a widespread area well inboard from the modern rift margin; samples from footwall blocks that bound the inland Jizil and Hamd half-grabens yield apatite (U-Th)/He cooling ages of 14.7 ± 0.9 Ma and 24.5 ± 1.5 Ma, respectively. The mid-Miocene age

  9. Automated system for analyzing stress intensity factors of three-dimensional cracks: Its application to analyses of two dissimilar semi-elliptical surface cracks in plates

    SciTech Connect

    Yoshimura, S.; Lee, J.S.; Yagawa, G.

    1997-02-01

    This paper describes a new automated system for analyzing the stress intensity factors (SIFs) of three-dimensional cracks. A geometry model containing one or several three-dimensional cracks is defined using a commercial CAD system, DESIGNBASE. Several local distributions of node density are chosen from the database of the present system, and then automatically superposed on one another over the geometry model by using the fuzzy knowledge processing. Nodes are generated by the bucketing method, and ten-noded quadratic tetrahedral solid elements are generated by the Delaunay method. A user imposes material properties and boundary conditions onto parts of the geometry model such as loops and edges by clicking them with a mouse and by inputting values. For accurate analyses of the stress intensity factors, finer elements are generated in the vicinity of crack tips, thanks to the fuzzy knowledge processing. The singular elements such that the midpoint nodes near crack front are shifted at the quarter-points are automatically placed along the three-dimensional crack front. The complete finite element model generated is given to a commercial finite element code, MARC, and a stress analysis is performed. The stress intensity factors are calculated using the displacement extrapolation method. To demonstrate practical performances of the present system, two dissimilar semi-elliptical surface cracks in a plate subjected to uniform tension are solved, and their interaction effects are discussed in detail. It is shown from the results that ASME Boiler and Pressure Vessel Code, Section 11, Appendix A gives a conservative stress intensity factor for two identical adjacent surface cracks and for two dissimilar adjacent surface cracks.

  10. A protein-protein binding assay using coated microtitre plates: increased throughput, reproducibility and speed compared to bead-based assays.

    PubMed

    Craig, Tim J; Ciufo, Leonora F; Morgan, Alan

    2004-07-30

    Protein-protein interactions, and the factors affecting them, are of fundamental importance to all biological systems. Surface plasmon resonance (SPR) and isothermal titration calorimetry (ITR) are powerful methods for assaying such interactions, but are expensive to implement. In contrast, bead-based pull-down assays using affinity tags such as glutathione-S-transferase (GST), require no specialist equipment. As a result, such assays are the most popular method for analysing protein-protein interactions, despite being time-consuming and prone to variability. In respect of these problems, we have modified this form of binding assay, using glutathione-coated 96-well plates rather than glutathione-Sepharose beads to bind the primary bait protein. Quantitation of bound protein utilises ELISA for purified proteins and scintillation counting for in vitro translated proteins, rather than the SDS-PAGE-based detection methods used in traditional bead-based assays. These modifications result in an approximately 10-fold increase in the number of samples that can be assayed daily, and allow results to be obtained within hours as opposed to days. We validate the modified assay by analysing the equilibrium binding of Munc18 and syntaxin, and also demonstrate that association and dissociation kinetics may be measured using this approach. The method we describe is generally applicable to any protein-protein interaction assay based on affinity tags and is amenable to automation, and so should benefit a wide range of biochemical research. PMID:15236910

  11. New Method for Accurate Calibration of Micro-Channel Plate based Detection Systems and its use in the Fast Plasma Investigation of NASA's Magnetospheric MultiScale Mission

    NASA Astrophysics Data System (ADS)

    Gliese, U.; Avanov, L. A.; Barrie, A.; Kujawski, J. T.; Mariano, A. J.; Tucker, C. J.; Chornay, D. J.; Cao, N. T.; Zeuch, M.; Pollock, C. J.; Jacques, A. D.

    2013-12-01

    The Fast Plasma Investigation (FPI) of the NASA Magnetospheric MultiScale (MMS) mission employs 16 Dual Electron Spectrometers (DESs) and 16 Dual Ion Spectrometers (DISs) with 4 of each type on each of 4 spacecraft to enable fast (30ms for electrons; 150ms for ions) and spatially differentiated measurements of full the 3D particle velocity distributions. This approach presents a new and challenging aspect to the calibration and operation of these instruments on ground and in flight. The response uniformity and reliability of their calibration and the approach to handling any temporal evolution of these calibrated characteristics all assume enhanced importance in this application, where we attempt to understand the meaning of particle distributions within the ion and electron diffusion regions. Traditionally, the micro-channel plate (MCP) based detection systems for electrostatic particle spectrometers have been calibrated by setting a fixed detection threshold and, subsequently, measuring a detection system count rate plateau curve to determine the MCP voltage that ensures the count rate has reached a constant value independent of further variation in the MCP voltage. This is achieved when most of the MCP pulse height distribution (PHD) is located at higher values (larger pulses) than the detection amplifier threshold. This method is adequate in single-channel detection systems and in multi-channel detection systems with very low crosstalk between channels. However, in dense multi-channel systems, it can be inadequate. Furthermore, it fails to fully and individually characterize each of the fundamental parameters of the detection system. We present a new detection system calibration method that enables accurate and repeatable measurement and calibration of MCP gain, MCP efficiency, signal loss due to variation in gain and efficiency, crosstalk from effects both above and below the MCP, noise margin, and stability margin in one single measurement. The fundamental

  12. Tectonic Plate Movement.

    ERIC Educational Resources Information Center

    Landalf, Helen

    1998-01-01

    Presents an activity that employs movement to enable students to understand concepts related to plate tectonics. Argues that movement brings topics to life in a concrete way and helps children retain knowledge. (DDR)

  13. Flat plate solar oven

    SciTech Connect

    Parikh, M.

    1981-01-01

    The construction of an Indian Rs. 186 (US $20.33) flat-plate solar oven is described. Detailed drawings are provided and relevant information on cooking times and temperature for different foods is given.

  14. Plate tectonics: Metamorphic myth

    NASA Astrophysics Data System (ADS)

    Korenaga, Jun

    2016-01-01

    Clear evidence for subduction-induced metamorphism, and thus the operation of plate tectonics on the ancient Earth has been lacking. Theoretical calculations indicate that we may have been looking for something that cannot exist.

  15. Violin plate modes.

    PubMed

    Gough, Colin

    2015-01-01

    As the first step toward developing a generic model for the acoustically radiating vibrational modes of the violin and related instruments, the modes of both freely supported and edge-constrained top and back plates have been investigated as functions of shape, arching height, elastic anisotropy, the f-holes and associated island area, thickness graduations, and the additional boundary constraints of the ribs, soundpost, and bass-bar present in the assembled instrument. Comsol shell structure finite element software has been used as a quasi-experimental tool, with physical and geometric properties varied smoothly, often over several orders of magnitude, allowing the development of the plate modes to be followed continuously from those of an initially square plate to those of doubly-arched, guitar-shaped, orthotropic plates and their dependence on all the above factors. PMID:25618046

  16. A hypothesis for Proterozoic-Phanerozoic supercontinent cyclicity, with implications for mantle convection, plate tectonics and Earth system evolution

    NASA Astrophysics Data System (ADS)

    Grenholm, Mikael; Scherstén, Anders

    2015-11-01

    relation to mantle convection and Earth system evolution.

  17. Positive battery plate

    NASA Technical Reports Server (NTRS)

    Rowlette, John R. (Inventor)

    1985-01-01

    The power characteristics of a lead acid battery are improved by incorporating a dispersion of 1 to 10% by weight of a thermodynamically stable conductivity additive, such as conductive tin oxide coated glass fibers (34) of filamentary glass wool (42) in the positive active layer (32) carried on the grid (30) of the positive plate (16). Positive plate potential must be kept high enough to prevent reduction of the tin oxide to tin by utilizing an oversized, precharged positive paste.

  18. Fractal multifiber microchannel plates

    NASA Technical Reports Server (NTRS)

    Cook, Lee M.; Feller, W. B.; Kenter, Almus T.; Chappell, Jon H.

    1992-01-01

    The construction and performance of microchannel plates (MCPs) made using fractal tiling mehtods are reviewed. MCPs with 40 mm active areas having near-perfect channel ordering were produced. These plates demonstrated electrical performance characteristics equivalent to conventionally constructed MCPs. These apparently are the first MCPs which have a sufficiently high degree of order to permit single channel addressability. Potential applications for these devices and the prospects for further development are discussed.

  19. Strongly coupled stress waves in heterogeneous plates.

    NASA Technical Reports Server (NTRS)

    Wang, A. S. D.; Chou, P. C.; Rose, J. L.

    1972-01-01

    Consideration of coupled stress waves generated by an impulsive load applied at one end of a semiinfinite plate. For the field equations governing the one-dimensional coupled waves a hyperbolic system of equations is obtained in which a strong coupling in the second derivatives exists. The method of characteristics described by Chou and Mortimer (1967) is extended to cover the case of strong coupling, and a study is made of the transient stress waves in a semiinfinite plate subjected to an initial step input. Coupled discontinuity fronts are found to propagate at different velocities. The normal plate stress and the bending moment at different time regimes are illustrated by graphs.

  20. Phononic plate waves.

    PubMed

    Wu, Tsung-Tsong; Hsu, Jin-Chen; Sun, Jia-Hong

    2011-10-01

    In the past two decades, phononic crystals (PCs) which consist of periodically arranged media have attracted considerable interest because of the existence of complete frequency band gaps and maneuverable band structures. Recently, Lamb waves in thin plates with PC structures have started to receive increasing attention for their potential applications in filters, resonators, and waveguides. This paper presents a review of recent works related to phononic plate waves which have recently been published by the authors and coworkers. Theoretical and experimental studies of Lamb waves in 2-D PC plate structures are covered. On the theoretical side, analyses of Lamb waves in 2-D PC plates using the plane wave expansion (PWE) method, finite-difference time-domain (FDTD) method, and finite-element (FE) method are addressed. These methods were applied to study the complete band gaps of Lamb waves, characteristics of the propagating and localized wave modes, and behavior of anomalous refraction, called negative refraction, in the PC plates. The theoretical analyses demonstrated the effects of PC-based negative refraction, lens, waveguides, and resonant cavities. We also discuss the influences of geometrical parameters on the guiding and resonance efficiency and on the frequencies of waveguide and cavity modes. On the experimental side, the design and fabrication of a silicon-based Lamb wave resonator which utilizes PC plates as reflective gratings to form the resonant cavity are discussed. The measured results showed significant improvement of the insertion losses and quality factors of the resonators when the PCs were applied. PMID:21989878

  1. Ethics issues in scientific data and service provision: evidence and challenges for the European Plate Observing System (EPOS)

    NASA Astrophysics Data System (ADS)

    Cocco, Massimo; Freda, Carmela; Haslinger, Florian; Consortium, Epos

    2016-04-01

    Addressing Ethics issues is nowadays a relevant challenge for any initiative, program or project dealing with scientific data and products provision, access to services for scientific purposes and communication with different stakeholders, including society. This is corroborated by the evidence that Ethics has very high priority in EU funded research. Indeed, all the activities carried out under Horizon 2020 must comply with ethical principles and national, Union and international legislation. This implies that "For all activities funded by the European Union, Ethics is an integral part of research from beginning to end, and ethical compliance is seen as pivotal to achieve real research excellence." Here, we present the experience of EPOS, a public pan-European research infrastructure. EPOS aims at integrating data, data products, services and software (DDSS) for solid Earth science generated and provided by monitoring networks, observing systems and facilities belonging to European countries. EPOS fosters the integrated use of multidisciplinary solid Earth data to improve the understanding of physical and chemical processes controlling earthquakes, volcanic eruptions, tsunamis as well as those driving tectonics and surface dynamics. The EPOS integration plan will make significant contributions to understanding and mitigating geo-hazards, yielding data for hazard assessment, data products for engaging different stakeholders, and services for training, education and communication to society. Numerous national research infrastructures engaged in EPOS are deployed for the monitoring of areas prone to geo-hazards and for the surveillance of the national territory including areas used for exploiting geo-resources. The EPOS community is therefore already trained to provide services to public (civil defence agencies, local and national authorities) and private (petroleum industry, mining industry, geothermal companies, aviation security) stakeholders. Our ability to

  2. Lateral plate number in low-plated threespine stickleback: a study of plasticity and heritability.

    PubMed

    Hansson, Truls H; Fischer, Barbara; Mazzarella, Anna B; Voje, Kjetil L; Vøllestad, Leif Asbjørn

    2016-05-01

    In the threespine stickleback Gasterosteus aculeatus model system, phenotypes are often classified into three morphs according to lateral plate number. Morph identity has been shown to be largely genetically determined, but substantial within-morph variation in plate number exists. In this study, we test whether plate number has a plastic component in response to salinity in the low-plated morph using a split-clutch experiment where families were split in two, one half raised in water at 0 and the other at 30 ppt salt. We find a small salinity-induced plastic effect on plate number in an unexpected direction, opposite to what we predicted: Fish raised in freshwater on average have slightly more plates than fish raised in saltwater. Our results confirm that heritability of plate number is high. Additionally, we find that variance in plate number at the family level can be predicted from other family level traits, which might indicate that epistatic interactions play a role in creating the observed pattern of lateral plate number variation. PMID:27096076

  3. Stress Orientations In Northern California Point To Variations In Frictional Strength Along Plate Boundary System and To Anomalous Stresses Near Sutter Buttes

    NASA Astrophysics Data System (ADS)

    Provost, A.-S.; Houston, H.

    The level of the frictional strength of the San Andreas Fault system has been a point of contention for over two decades. We determined orientations of principal stresses around the San Andreas Fault system in the greater Bay Area and regions further north along the strike-slip plate boundary. Stress orientations, as well as a ratio be- tween stress magnitudes, were determined by inversions of ~ 6000 earthquake fault plane solutions, divided into~100 groups based on the spatial distribution of seismic- ity with respect to major regional fault strands (i.e., the SAF, the Hayward-Rodgers Creek-Maacama fault zones, and the Calaveras-Green Valley-Bartlett Springs fault zones). The stress orientations, while spatially variable, show several features; to de- scribe them, it is useful to distinguish between groups of events occurring on and off the major fault strands. First, for off-fault groups, the angle between major fault strands and the maximum horizontal compression SH decreases systematically to the north. This contrasts with the high angles of SH (70 to 85) found immediately adja- cent to, as well as farther from, the creeping segment of the SAF in central California by Provost and Houston [JGR, 2001]. Second, for on-fault groups, the angle that SH makes with major fault strands changes but little along strike, averaging 50 to 55 in the creeping segment, the Bay Area, and the northernmost part of our study area. Third, as in the vicinity of the creeping segment of the SAF in central California, the majority of off-fault groups, as well as the on-fault groups, are in a strike-slip, rather than thrust, tectonic regime. Finally, anomalous east-west SH orientations are seen for three groups in the vicinity of Sutter Buttes, possibly related to an isolated fragment of subducted slab that has been imaged below this region. Only 10 to 20 km away SH lies in the more typical north-south orientation. In both cases, the seismicity in this region is relatively deep, between

  4. Stress Orientations in Northern California Point to Variations in Frictional Strength Along Plate Boundary System and to Anomalous Stresses Near Sutter Buttes

    NASA Astrophysics Data System (ADS)

    Provost, A.; Houston, H.

    2001-12-01

    The level of the frictional strength of the San Andreas Fault system has been a point of contention for over two decades. We determined orientations of principal stresses around the San Andreas Fault system in the greater Bay Area and regions further north along the strike-slip plate boundary. Stress orientations, as well as a ratio between stress magnitudes, were determined by inversions of ~6000 earthquake fault plane solutions, divided into ~100 groups based on the spatial distribution of seismicity with respect to major regional fault strands (i.e., the SAF, the Hayward-Rodgers Creek-Maacama fault zones, and the Calaveras-Green Valley-Bartlett Springs fault zones). The stress orientations, while spatially variable, show several features; to describe them, it is useful to distinguish between groups of events occurring on and off the major fault strands. First, for off-fault groups, the angle between major fault strands and the maximum horizontal compression SH decreases systematically to the north. This contrasts with the high angles of SH (70° to 85° ) found immediately adjacent to, as well as farther from, the creeping segment of the SAF in central California by Provost and Houston [JGR, 2001]. Second, for on-fault groups, the angle that SH makes with major fault strands changes but little along strike, averaging 50° to 55° in the creeping segment, the Bay Area, and the northernmost part of our study area. Third, as in the vicinity of the creeping segment of the SAF in central California, the majority of off-fault groups, as well as the on-fault groups, are in a strike-slip, rather than thrust, tectonic regime. Finally, anomalous east-west SH orientations are seen for three groups in the vicinity of Sutter Buttes, possibly related to an isolated fragment of subducted slab that has been imaged below this region. Only 10 to 20 km away SH lies in the more typical north-south orientation. In both cases, the seismicity in this region is relatively deep, between

  5. Electrochemical cell and separator plate thereof

    DOEpatents

    Baker, Bernard S.; Dharia, Dilip J.

    1979-10-02

    A fuel cell includes a separator plate having first and second flow channels extending there through contiguously with an electrode and respectively in flow communication with the cell electrolyte and in flow isolation with respect to such electrolyte. In fuel cell system arrangement, the diverse type channels are supplied in common with process gas for thermal control purposes. The separator plate is readily formed by corrugation of integral sheet material. 10 figs.

  6. Electrochemical cell and separator plate thereof

    DOEpatents

    Baker, Bernard S.; Dharia, Dilip J.

    1979-01-01

    A fuel cell includes a separator plate having first and second flow channels extending therethrough contiguously with an electrode and respectively in flow communication with the cell electrolyte and in flow isolation with respect to such electrolyte. In fuel cell system arrangement, the diverse type channels are suplied in common with process gas for thermal control purposes. The separator plate is readily formed by corrugation of integral sheet material.

  7. A clamped rectangular plate containing a crack

    NASA Technical Reports Server (NTRS)

    Tang, R.; Erdogan, F.

    1985-01-01

    The general problem of a rectangular plate clamped along two parallel sides and containing a crack parallel to the clamps is considered. The problem is formulated in terms of a system of singular integral equations and the asymptotic behavior of the stress state near the corners is investigated. Numerical examples are considered for a clamped plate without a crack and with a centrally located crack, and the stress intensity factors and the stresses along the clamps are calculated.

  8. Plated-through hole testing. Final repot

    SciTech Connect

    Abel, W.B.

    1980-05-01

    An improved microresistance testing method to measure the thickness of copper plating in plated-through holes of double-sided printed wiring boards is presented. A new probe design, combined with a microprocessor controller, makes it possible for a direct reading tester to provide variables data. Tester design and software programs for the system are included. Results of correlation studies, comparing the improved resistance method to cross-sectional measurements are presented. Limitations on the microresistance test method are discussed.

  9. Caribbean plate interactions

    SciTech Connect

    Ball, M. )

    1993-02-01

    Vector analysis of plate motions, derived from studies of Atlantic magnetic lineations and fracture zone trends, indicates the following relative movements between the Caribbean, North American, and South American Plates. (1) During Early Jurassic to Early Cretaceous, the North American Plate moved 1900 km westward and 900 km northward relative to the South American Plate. A broad zone including the Caribbean region, i.e., the zone between the North and South America Plates, was a site of left-lateral shear and north-south extension. (2) During Early Cretaceous to Late Cretaceous, the North American Mate moved an additional 1200 km westward relative to South America across this zone. (3) During Late Cretaceous to the end of the Eocene, the North American Plate moved 200 km westward and 400 km northward relative to the South American Plate. (4) From the end of the Eocene to near the end of the Miocene, North America converged on South America some 200 km and moved 100 km eastward relative to it. Through the Mesozoic and earliest Tertiary history of the Caribbean, the region was a shear zone within which left-lateral displacement exceeded 3000 km and north-south extension exceeded 1300 km. In regard to time, 80% of the history of the Caribbean region is one of north-south extension and left-lateral shear. In terms of space, 97% of the shear is left-lateral and the ratio of divergence versus convergence is 7 to 1. Thus, characterizing the Caribbean region, and the Atlantic to its east, as a zone of north-south extension and left-lateral shear, is a fair generalization.

  10. Using Plate Mapping to Examine Portion Size and Plate Composition for Large and Small Divided Plates

    PubMed Central

    Sharp, David E.; Sobal, Jeffery; Wansink, Brian

    2015-01-01

    Does the size of a plate influence the serving of all items equally, or does it influence the serving of some foods – such as meat versus starch versus vegetables – very differently? To examine this, we utilize a promising new plate mapping method where people drew a meal on a paper plate to examine sensitivity to small versus large three-compartment divided plates in portion size and meal composition in a sample of 109 university students. The total drawn meal area was 37% bigger on large plates than small plates, that is, the portion of plate coverage did not differ by plate size. Men and women drew bigger vegetable portions and men drew bigger meat portions on large plates when compared to small plates. These results suggest that men and women are differentially sensitive to plate size for overall meal size and for meal composition. Implications for decreasing portion size and improving meal balance are discussed. PMID:25280373

  11. Improvements in Cold-Plate Fabrication

    NASA Technical Reports Server (NTRS)

    Zaffetti, Mark A.; Taddey, Edmund P.; Laurin, Michael B.; Chabebe, Natalia

    2012-01-01

    Five improvements are reported in cold-plate fabrication. This cold plate is part of a thermal control system designed to serve on space missions. The first improvement is the merging of the end sheets of the cold plate with the face sheets of the structural honeycomb panel. The cold plate, which can be a brazed assembly, uses the honeycomb face sheet as its end sheet. Thus, when the honeycomb panel is fabricated, the face sheet that is used is already part of the cold plate. In addition to reducing weight, costs, and steps, the main benefit of this invention is that it creates a more structurally sound assembly. The second improvement involves incorporation of the header into the closure bar to pass the fluid to a lower layer. Conventional designs have used a separate header, which increases the geometry of the system. The improvement reduces the geometry, thus allowing the cold plate to fit into smaller area. The third improvement eliminates the need of hose, tube, or manifold to supply the cooling fluid externally. The external arrangement can be easily damaged and is vulnerable to leakage. The new arrangement incorporates an internal fluid transfer tube. This allows the fluid to pass from one cold plate to the other without any exposed external features. The fourth improvement eliminates separate fabrication of cold plate(s) and structural members followed by a process of attaching them to each other. Here, the structural member is made of material that can be brazed just as that of the cold plate. Now the structural member and the cold plate can be brazed at the same time, creating a monolithic unit, and thus a more structurally sound assembly. Finally, the fifth improvement is the elimination of an additional welding step that can damage the braze joints. A tube section, which is usually welded on after the braze process, is replaced with a more structurally sound configuration that can be brazed at the same time as the rest of the cold plate.

  12. Study on plate silencer with general boundary conditions

    NASA Astrophysics Data System (ADS)

    Liu, Gongmin; Zhao, Xiaochen; Zhang, Wenping; Li, Shuaijun

    2014-09-01

    A plate silencer consists of an expansion chamber with two side-branch rigid cavities covered by plates. Previous studies showed that, in a duct, the introduction of simply supported or clamped plates into an air conveying system could achieve broadband quieting from low to medium frequencies. In this study, analytical formulation is extended to the plate silencer with general boundary conditions. A set of static beam functions, which are a combination of sine series and third-order polynomial, is employed as the trial functions of the plate vibration velocity. Greens function and Kirchhoff-Helmholtz integral are used to solve the sound radiation in the duct and the cavity, and then the vibration velocity of the plate is obtained. Having obtained the vibration velocity, the pressure perturbations induced by the plate oscillation and the transmission loss are found. Optimization is carried out in order to obtain the widest stopband. The transmission loss calculated by the analytical method agrees closely with the result of the finite element method simulation. Further studies with regard to the plate under several different classical boundary conditions based on the validated model show that a clamped-free plate silencer has the worst stopband. Attempts to release the boundary restriction of the plate are also made to study its effect on sound reflection. Results show that a softer end for a clamped-clamped plate silencer helps increase the optimal bandwidth, while the same treatment for simply supported plate silencer will result in performance degradation.

  13. Simple defined autoinduction medium for high-level recombinant protein production using T7-based Escherichia coli expression systems.

    PubMed

    Li, Zhaopeng; Kessler, Wolfgang; van den Heuvel, Joop; Rinas, Ursula

    2011-08-01

    Protein production under the control of lac operon regulatory elements using autoinduction is based on diauxic growth of Escherichia coli on lactose after consumption of more preferred carbon substrates. A novel simple and cost-effective defined autoinduction medium using a mixture of glucose, glycerol, and lactose as carbon substrate and NH(4)(+) as sole nitrogen source without any supplementation of amino acids and vitamins was developed for T7-based E. coli expression systems. This medium was successfully employed in 96-well microtiter plates, test tubes, shake flasks, and 15-L bioreactor cultivations for production of different types of proteins achieving an average yield of 500 mg L(-1) product. Cell-specific protein concentrations and solubility were similar as during conventional isopropyl β-D-1-thiogalactopyranoside induction using Luria-Bertani broth. However, the final yield of target proteins was about four times higher, as a higher final biomass was achieved using this novel defined autoinduction broth. PMID:21698378

  14. Bipolar battery plate

    NASA Technical Reports Server (NTRS)

    Rowlette, John J. (Inventor)

    1987-01-01

    A liquid-impermeable plate (10) having through-plate conductivity with essentially zero resistance comprises an insulator sheet (12) having a series of spaced perforations (14) each of which contains a metal element (16) sealingly received into the perforation (14). A low-cost plate can readily be manufactured by punching a thermoplastic sheet (40) such as polypropylene with a punching tool (52), filling the apertures with led spheres (63) having a diameter smaller than the holes (50) but larger than the thickness of the sheet, sweeping excess spheres (62) off the sheet with a doctor blade (60) and then pressing a heated platen (74) onto the sheet to swage the spheres into a cylindrical shape and melt the surrounding resin to form a liquid-impermeable collar (4) sealing the metal into the sheet.

  15. [Theoretical analysis and numerical simulation of effect of steel plate positions on steel plate rigidity in internal fixation of bone surgery].

    PubMed

    Chen, Bingzhi; Gu, Yuanxian; Lü, Decheng; Lü, Xuemin

    2003-09-01

    In this study we calculate theoretically and use FEM to simulate the effect of plate position relative to bending direction on the overall bending stiffness of the composite system plate-bone. The results show that for different bending directions the effect of the modulus of elasticity of the plate is negligible. Changing the position of a plate will often alter the stress obviously. During the operation, the steel plate should be assigned onto the tension side of the bone. PMID:14565005

  16. Optimization of a closed-loop gas system for the operation of Resistive Plate Chambers at the Large Hadron Collider experiments

    NASA Astrophysics Data System (ADS)

    Capeans, M.; Glushkov, I.; Guida, R.; Hahn, F.; Haider, S.

    2012-01-01

    Resistive Plate Chambers (RPCs), thanks to their fast time resolution (˜1 ns), suitable space resolution (˜1 cm) and low production cost (˜50 €/m2), are widely employed for the muon trigger systems at the Large Hadron Collider (LHC). Their large detector volume (they cover a surface of about 4000 m2 equivalent to 16 m3 of gas volume both in ATLAS and CMS) and the use of a relatively expensive Freon-based gas mixture make a closed-loop gas circulation unavoidable. It has been observed that the return gas of RPCs operated in conditions similar to the difficult experimental background foreseen at LHC contains a large amount of impurities potentially dangerous for long-term operation. Several gas-cleaning agents are currently in use in order to avoid accumulation of impurities in the closed-loop circuits. We present the results of a systematic study characterizing each of these cleaning agents. During the test, several RPCs were operated at the CERN Gamma Irradiation Facility (GIF) in a high radiation environment in order to observe the production of typical impurities: mainly fluoride ions, molecules of the Freon group and hydrocarbons. The polluted return gas was sent to several cartridges, each containing a different cleaning agent. The effectiveness of each material was studied using gas chromatography and mass-spectrometry techniques. Results of this test have revealed an optimized configuration of filters that is now under long-term validation.Gas optimization studies are complemented with a finite element simulation of gas flow distribution in the RPCs, aiming at its eventual optimization in terms of distribution and flow rate.

  17. Nitrided Metallic Bipolar Plates

    SciTech Connect

    Brady, Michael P; Tortorelli, Peter F; Pihl, Josh A; Toops, Todd J; More, Karren Leslie; Meyer III, Harry M; Vitek, John Michael; Wang, Heli; Turner, John; Wilson, Mahlon; Garzon, Fernando; Rockward, Tommy; Connors, Dan; Rakowski, Jim; Gervasio, Don

    2008-01-01

    The objectives are: (1) Develop and optimize stainless steel alloys amenable to formation of a protective Cr-nitride surface by gas nitridation, at a sufficiently low cost to meet DOE targets and with sufficient ductility to permit manufacture by stamping. (2) Demonstrate capability of nitridation to yield high-quality stainless steel bipolar plates from thin stamped alloy foils (no significant stamped foil warping or embrittlement). (3) Demonstrate single-cell fuel cell performance of stamped and nitrided alloy foils equivalent to that of machined graphite plates of the same flow-field design ({approx}750-1,000 h, cyclic conditions, to include quantification of metal ion contamination of the membrane electrode assembly [MEA] and contact resistance increase attributable to the bipolar plates). (4) Demonstrate potential for adoption in automotive fuel cell stacks. Thin stamped metallic bipolar plates offer the potential for (1) significantly lower cost than currently-used machined graphite bipolar plates, (2) reduced weight/volume, and (3) better performance and amenability to high volume manufacture than developmental polymer/carbon fiber and graphite composite bipolar plates. However, most metals exhibit inadequate corrosion resistance in proton exchange membrane fuel cell (PEMFC) environments. This behavior leads to high electrical resistance due to the formation of surface oxides and/or contamination of the MEA by metallic ions, both of which can significantly degrade fuel cell performance. Metal nitrides offer electrical conductivities up to an order of magnitude greater than that of graphite and are highly corrosion resistant. Unfortunately, most conventional coating methods (for metal nitrides) are too expensive for PEMFC stack commercialization or tend to leave pinhole defects, which result in accelerated local corrosion and unacceptable performance.

  18. Plate-mantle coupling from post-Pangea plate kinematics

    NASA Astrophysics Data System (ADS)

    Zahirovic, Sabin; Dietmar Müller, R.; Seton, Maria; Flament, Nicolas

    2015-04-01

    Convection in the Earth's mantle that involves plates at the surfaces gives rise to plate velocities that vary through time and depend on the balance of plate boundary forces, with the present-day providing a snapshot of this ongoing process. However, present-day plate velocities do not capture plate behaviour over geologically representative timeframes and thus cannot be used to evaluate factors limiting plate velocities. Previous studies investigated the effects of continental keels on plate speeds by either using the present-day snapshot or a limited number of reconstructed plate configurations, often leading to conflicting results. For example, an early assumption was that continental keels (especially cratons) were unlikely to impede fast plate motions because India's velocity approached ~20 cm/yr in the Eocene prior to the collision with Eurasia. We employ a modern plate reconstruction approach with evolving global topological plate boundaries for the post-Pangea timeframe (since 200 Ma) to evaluate factors controlling plate velocities. Plate boundary configurations and plate velocities are extracted from the open-source and cross-platform plate reconstruction package GPlates (www.gplates.org) at 1 Myr intervals. For each plate, at each timestep, the area of continental and cratonic lithosphere is calculated to evaluate the effect on plate velocities. Our results support that oceanic plates tend to be 2-3 times faster than plates with large portion of continental plate area, consistent with predictions of numerical models of mantle convection. The fastest plates (~8.5 cm/yr RMS) are dominated by oceanic plate area and high subducting portion of plate perimeter, while the slowest plates (~2.6-2.8 cm/yr RMS) are dominated by continental plate area and bounded by transforms and mid-oceanic ridge segments. Importantly, increasing cratonic fractions (both Proterozoic and Archean lithosphere) significantly impede plate velocities, suggesting that deep continental

  19. Reduced Plating Ignitron

    NASA Technical Reports Server (NTRS)

    Polzin, Kurt A (Inventor); Pearson, J Boise (Inventor)

    2014-01-01

    An ignitron apparatus has an airtight tubular housing having a first sealed end and a second sealed end. An anode is connected at the first sealed end, projecting into the housing, and a recess at the second sealed and forms a well which contains a quantity of liquid gallium or gallium alloy making up the cathode. An ignitor projects through the liquid metal and into the housing. The inner surface of the housing includes at least one plating-reduction structure to prevent electrical shorting of the apparatus caused by plating of the liquid metal.

  20. NICKEL PLATING PROCESS

    DOEpatents

    Hoover, T.B.; Zava, T.E.

    1959-05-12

    A simplified process is presented for plating nickel by the vapor decomposition of nickel carbonyl. In a preferred form of the invention a solid surface is nickel plated by subjecting the surface to contact with a mixture containing by volume approximately 20% nickel carbonyl vapor, 2% hydrogen sulfide and .l% water vapor or 1% oxygen and the remainder carbon dioxide at room temperature until the desired thickness of nickel is obtained. The advantage of this composition over others is that the normally explosive nickel carbonyl is greatly stabilized.

  1. Image simulation for automatic license plate recognition

    NASA Astrophysics Data System (ADS)

    Bala, Raja; Zhao, Yonghui; Burry, Aaron; Kozitsky, Vladimir; Fillion, Claude; Saunders, Craig; Rodríguez-Serrano, José

    2012-01-01

    Automatic license plate recognition (ALPR) is an important capability for traffic surveillance applications, including toll monitoring and detection of different types of traffic violations. ALPR is a multi-stage process comprising plate localization, character segmentation, optical character recognition (OCR), and identification of originating jurisdiction (i.e. state or province). Training of an ALPR system for a new jurisdiction typically involves gathering vast amounts of license plate images and associated ground truth data, followed by iterative tuning and optimization of the ALPR algorithms. The substantial time and effort required to train and optimize the ALPR system can result in excessive operational cost and overhead. In this paper we propose a framework to create an artificial set of license plate images for accelerated training and optimization of ALPR algorithms. The framework comprises two steps: the synthesis of license plate images according to the design and layout for a jurisdiction of interest; and the modeling of imaging transformations and distortions typically encountered in the image capture process. Distortion parameters are estimated by measurements of real plate images. The simulation methodology is successfully demonstrated for training of OCR.

  2. Multiple sulfur isotope systematics of Icelandic geothermal fluids and the source and reactions of sulfur in volcanic geothermal systems at divergent plate boundaries

    NASA Astrophysics Data System (ADS)

    Stefánsson, Andri; Keller, Nicole S.; Robin, Jóhann Gunnarsson; Ono, Shuhei

    2015-09-01

    Multiple sulfur isotope systematics of geothermal fluids at Krafla, Northeast Iceland, were studied in order to determine the source and reactions of sulfur in this system, as an example of a geothermal system hosted on a divergent plate boundary. Fluid temperatures ranged from 192 to 437 °C, and the fluids have low Cl concentration between ∼10 and ∼150 ppm, with liquid water and vapor being present in the reservoir. Dissolved sulfide (S-II) and sulfate (SVI) predominated in the water phase with trace concentrations of thiosulfate (S2O32-) whereas sulfide (S-II) was the only species observed in the vapor phase. The reconstructed sulfur isotope ratios of the reservoir fluids based on samples collected at surface from two-phase and vapor only well discharges indicated that δ34S and Δ33S of sulfide in the reservoir fluid ranged from -1.5 to +1.1‰ and -0.001 to -0.017‰, respectively, whereas δ34S and Δ33S of sulfate were significantly different and ranged from +3.4 to +13.4‰ and 0.000 to -0.036‰, respectively. Depressurization boiling upon fluid ascent coupled with progressive fluid-rock interaction and sulfide mineral (pyrite) formation results in the liquid phase becoming progressively isotopically lighter with respect to both δ34S and Δ33S. In contrast, H2S in the vapor phase and pyrite become isotopically heavier. The observed Δ33S and δ34S systematics for geothermal fluids at Krafla suggest that the source of sulfide in the reservoir fluids is the basaltic magma, either through degassing or upon dissolution of unaltered basalts. At high temperatures, insignificant SO4 was observed in the fluids but below ∼230 °C significant concentrations of SO4 were observed, the source inferred to be H2S oxidation. The two key factors controlling the multiple sulfur isotope systematics of geothermal fluids are: (1) the isotopic composition of the source material and (2) the isotope fractionation associated with aqueous and vapor speciation and how these

  3. Impact Damage Detection in Composite Plates using a Self-diagnostic Electro-Mechanical Impedance-based Structural Health Monitoring System

    NASA Astrophysics Data System (ADS)

    Sharif-Khodaei, Z.; Ghajari, M.; Aliabadi, M. H.

    2015-03-01

    In this work, application of the electro-mechanical impedance (EMI) method in structural health monitoring as a damage detection technique has been investigated. A damage metric based on the real and imaginary parts of the impedance measures is introduced. Numerical and experimental tests are carried out to investigate the applicability of the method for various types of damage, such as debonding between the transducers and the plate, faulty sensors and impact damage in composite plates. The effect of several parameters, such as environmental effects, frequency sweep, severity of damage, location of damage, etc., on the damage metric has been reported.

  4. Cascade impactor and jet plate for same

    DOEpatents

    Dahlin, Robert S.; Farthing, William E.; Landham Jr., Edward C.

    2004-02-03

    A sampling system and method for sampling particulate matter from a high-temperature, high-pressure gas stream. A cyclone sampler for use at high temperatures and pressures, and having threadless sacrificial connectors is disclosed. Also disclosed is an improved cascade impactor including jet plates with integral spacers, and alignment features provided for aligning the jet plates with their associated collection substrates. An activated bauxite alkali collector is disclosed, and includes an alumina liner. The sampling system can be operated remotely or locally, and can be permanently installed or configured as a portable system.

  5. Ponderomotive phase plate for transmission electron microscopes

    DOEpatents

    Reed, Bryan W.

    2012-07-10

    A ponderomotive phase plate system and method for controllably producing highly tunable phase contrast transfer functions in a transmission electron microscope (TEM) for high resolution and biological phase contrast imaging. The system and method includes a laser source and a beam transport system to produce a focused laser crossover as a phase plate, so that a ponderomotive potential of the focused laser crossover produces a scattering-angle-dependent phase shift in the electrons of the post-sample electron beam corresponding to a desired phase contrast transfer function.

  6. Robot Arm with Tendon Connector Plate and Linear Actuator

    NASA Technical Reports Server (NTRS)

    Ihrke, Chris A. (Inventor); Diftler, Myron A. (Inventor); Bridgwater, Lyndon (Inventor); Nguyen, Vienny (Inventor); Millerman, Alexander (Inventor)

    2014-01-01

    A robotic system includes a tendon-driven end effector, a linear actuator, a flexible tendon, and a plate assembly. The linear actuator assembly has a servo motor and a drive mechanism, the latter of which translates linearly with respect to a drive axis of the servo motor in response to output torque from the servo motor. The tendon connects to the end effector and drive mechanism. The plate assembly is disposed between the linear actuator assembly and the tendon-driven end effector and includes first and second plates. The first plate has a first side that defines a boss with a center opening. The second plate defines an accurate through-slot having tendon guide channels. The first plate defines a through passage for the tendon between the center opening and a second side of the first plate. A looped end of the flexible tendon is received within the tendon guide channels.

  7. Nuclear reactor alignment plate configuration

    DOEpatents

    Altman, David A; Forsyth, David R; Smith, Richard E; Singleton, Norman R

    2014-01-28

    An alignment plate that is attached to a core barrel of a pressurized water reactor and fits within slots within a top plate of a lower core shroud and upper core plate to maintain lateral alignment of the reactor internals. The alignment plate is connected to the core barrel through two vertically-spaced dowel pins that extend from the outside surface of the core barrel through a reinforcement pad and into corresponding holes in the alignment plate. Additionally, threaded fasteners are inserted around the perimeter of the reinforcement pad and into the alignment plate to further secure the alignment plate to the core barrel. A fillet weld also is deposited around the perimeter of the reinforcement pad. To accomodate thermal growth between the alignment plate and the core barrel, a gap is left above, below and at both sides of one of the dowel pins in the alignment plate holes through with the dowel pins pass.

  8. Growth Plate Injuries

    MedlinePlus

    ... or crushed, the growth plate may close prematurely, forming a bony bridge or “bar.” The risk of ... this publication: James S. Panagis, M.D., M.P.H., NIAMS/NIH; R. Tracy Ballock, M.D., Case ...

  9. The Plate Tectonics Project

    ERIC Educational Resources Information Center

    Hein, Annamae J.

    2011-01-01

    The Plate Tectonics Project is a multiday, inquiry-based unit that facilitates students as self-motivated learners. Reliable Web sites are offered to assist with lessons, and a summative rubric is used to facilitate the holistic nature of the project. After each topic (parts of the Earth, continental drift, etc.) is covered, the students will…

  10. INL HIP Plate Fabrication

    SciTech Connect

    B. H. Park; C. R. Clark; J. F. Jue

    2010-02-01

    This document outlines the process used to bond monolithic fuel plates by Hot Isostatic Pressing (HIP). This method was developed at Idaho National Laboratory (INL) for the Reduced Enrichment for Research and Test Reactors (RERTR) program. These foils have been used in a number of irradiation experiments in support of the United States Global Threat Reduction Initiative (GTRI) program.

  11. Unitary plate electrode

    NASA Technical Reports Server (NTRS)

    Rowlette, John J. (Inventor); Clough, Thomas J. (Inventor); Josefowicz, Jack Y. (Inventor); Sibert, John W. (Inventor)

    1985-01-01

    The unitary electrode (10) comprises a porous sheet (12) of fiberglass the strands (14) of which contain a coating (16) of conductive tin oxide. The lower portion of the sheet contains a layer (18) of resin and the upper layer (20) contains lead dioxide forming a positive active electrode on an electrolyte-impervious layer. The strands (14) form a continuous conduction path through both layers (16, 18). Tin oxide is prevented from reduction by coating the surface of the plate facing the negative electrode with a conductive, impervious layer resistant to reduction such as a thin film (130) of lead or graphite filled resin adhered to the plate with a layer (31) of conductive adhesive. The plate (10) can be formed by casting a molten resin from kettle (60) onto a sheet of glass wool (56) overlying a sheet of lead foil and then applying positive active paste from hopper (64) into the upper layer (68). The plate can also be formed by passing an assembly of a sheet ( 80) of resin, a sheet (86) of sintered glass and a sheet (90) of lead between the nip (92) of heated rollers (93, 95) and then filling lead oxide into the pores (116) of the upper layer (118).

  12. Comparison of the TEMPO® System, Petrifilm® , and Cultural MPN Procedure for Enumeration of E. coli, Coliforms and Total Aerobic Plate Counts

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Introduction: Recent innovations in microbiological methods for analysis of food products have been in methods for detection of bacterial pathogens. Petrifilm dehydrated plates are the only significant addition to cultural procedures for indicator organisms in the last 20 years. An automated most...

  13. Polar Plate Theory for Orthogonal Anisotropy

    NASA Technical Reports Server (NTRS)

    Bailey, Michelle D.; Bower, Mark V.

    2000-01-01

    Laminated fiber-reinforced (or filamentary) composites are used today for their high strength-to-weight and stiffness-to-weight ratios. However, because of the anisotropic behavior of composites, determining the response on a macroscopic scale is challenging. This is particularly evident in the evaluation of the governing differential equations of a circular disk with the fibers of the lamina oriented with rectilinear orthogonality. This includes any situation involving a composite plate of circular geometry in which out-of-plane displacements due to load are desired, such as fastener pull through loading of a composite plate. Current analysis techniques use numerical methods with rectilinear coordinate systems to solve problems with circular geometry. These analyses over predict plate stiffness by 20% and underpredict failure by 70%. Consequently, there is a need to transform classical composite plate theory to a polar coordinate system. In order to better analyze structures with circular geometries the classical composite plate equations are transformed into the plate equations for a rectilinearly anisotropic composite in polar coordinates. A composite plate is typically a laminate of fibers in rectilinear directions. Subsequent to the lay-tip the necessary geometry is cut out of a rectangular plate. In a similar manner, the derivation of the plate equation starts with the fundamental definitions of strain, displacement and curvature and incorporates the material property angular dependence into the equilibrium equations for a differential polar element. In the transformed state, the stiffness coefficients are no longer constant, adding to the complexity of the governing differential equations. This paper discusses the new derivation and evaluation of the plate equations for a circular composite disk with orthogonal rectilinear anisotropy. The resultant new three partial differential equations, which describe the circular anisotropic plate, can be used to

  14. Models for rupture mechanics of plate boundaries and crustal deformation

    NASA Astrophysics Data System (ADS)

    Nur, A.

    1983-02-01

    The role of pull aparts and pushups in transcurrent systems, the rotation of faults and blocks within transcurrent fault systems, the role of accretion tectonics in plate boundary deformation, and power law creep behavior and the yielding at plate boundaries were investigated.

  15. 30 CFR 27.7 - Certification plate or label.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Certification plate or label. 27.7 Section 27.7... label. A certified methane-monitoring system or component thereof shall be identified with a certification plate or label which is attached to the system or component in a manner acceptable to MSHA....

  16. 30 CFR 27.7 - Certification plate or label.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Certification plate or label. 27.7 Section 27.7... label. A certified methane-monitoring system or component thereof shall be identified with a certification plate or label which is attached to the system or component in a manner acceptable to MSHA....

  17. 30 CFR 27.7 - Certification plate or label.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Certification plate or label. 27.7 Section 27.7... label. A certified methane-monitoring system or component thereof shall be identified with a certification plate or label which is attached to the system or component in a manner acceptable to MSHA....

  18. 30 CFR 27.7 - Certification plate or label.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Certification plate or label. 27.7 Section 27.7... label. A certified methane-monitoring system or component thereof shall be identified with a certification plate or label which is attached to the system or component in a manner acceptable to MSHA....

  19. Optimizing Two-Color Semiconductor Nanocrystal Immunoassays in Single Well Microtiter Plate Formats

    PubMed Central

    Sapsford, Kim E.; Spindel, Samantha; Jennings, Travis; Tao, Guoliang; Triulzi, Robert C.; Algar, W. Russ; Medintz, Igor L.

    2011-01-01

    The simultaneous detection of two analytes, chicken IgY (IgG) and Staphylococcal enterotoxin B (SEB), in the single well of a 96-well plate is demonstrated using luminescent semiconductor quantum dot nanocrystal (NC) tracers. The NC-labeled antibodies were prepared via sulfhydryl-reactive chemistry using a facile protocol that took <3 h. Dose response curves for each target were evaluated in a single immunoassay format and compared to Cy5, a fluorophore commonly used in fluorescent immunoassays, and found to be equivalent. Immunoassays were then performed in a duplex format, demonstrating multiplex detection in a single well with limits of detection equivalent to the single assay format: 9.8 ng/mL chicken IgG and 7.8 ng/mL SEB. PMID:22164051

  20. This-layer chromatography/electrospray ionization triple-quadrupole linear ion trap mass spectrometry system: analysis of rhodamine dyes separated on reversed-phase C8 plates

    SciTech Connect

    Ford, Michael J; Kertesz, Vilmos; Van Berkel, Gary J

    2005-01-01

    The direct analysis of separated rhodamine dyes on reversed-phase C{sub 8} thin-layer chromatography plates using a surface sampling/electrospray emitter probe coupled with a triple-quadrupole linear ion trap mass spectrometer is presented. This report represents continuing work to advance the performance metrics and utility of this basic surface sampling electrospray mass spectrometry system for the analysis of thin-layer chromatography plates. Experimental results examining the role of sampling probe spray end configuration on liquid aspiration rate and gas-phase ion signal generated are discussed. The detection figures-of-merit afforded by full-scan, automated product ion and selected reaction monitoring modes of operation were examined. The effect of different eluting solvents on mass spectrum signal levels with the reversed-phase C{sub 8} plate was investigated. The combined effect of eluting solvent flow-rate and development lane surface scan rate on preservation of chromatographic resolution was also studied. Analysis of chromatographically separated red pen ink extracts from eight different pens using selected reaction monitoring demonstrated the potential of this surface sampling electrospray mass spectrometry system for targeted compound analysis with real samples.

  1. Principal visual word discovery for automatic license plate detection.

    PubMed

    Zhou, Wengang; Li, Houqiang; Lu, Yijuan; Tian, Qi

    2012-09-01

    License plates detection is widely considered a solved problem, with many systems already in operation. However, the existing algorithms or systems work well only under some controlled conditions. There are still many challenges for license plate detection in an open environment, such as various observation angles, background clutter, scale changes, multiple plates, uneven illumination, and so on. In this paper, we propose a novel scheme to automatically locate license plates by principal visual word (PVW), discovery and local feature matching. Observing that characters in different license plates are duplicates of each other, we bring in the idea of using the bag-of-words (BoW) model popularly applied in partial-duplicate image search. Unlike the classic BoW model, for each plate character, we automatically discover the PVW characterized with geometric context. Given a new image, the license plates are extracted by matching local features with PVW. Besides license plate detection, our approach can also be extended to the detection of logos and trademarks. Due to the invariance virtue of scale-invariant feature transform feature, our method can adaptively deal with various changes in the license plates, such as rotation, scaling, illumination, etc. Promising results of the proposed approach are demonstrated with an experimental study in license plate detection. PMID:22614654

  2. PC-based car license plate reader

    NASA Astrophysics Data System (ADS)

    Hwang, Chung-Mu; Shu, Shyh-Yeong; Chen, Wen-Yu; Chen, Yie-Wern; Wen, Kuang-Pu

    1992-11-01

    A car license plate reader (CLPR) using fuzzy inference and neural network algorithm has been developed in Industrial Technology Research Institute (ITRI) and installed in highway toll stations to identify stolen cars. It takes an average of 0.7 seconds to recognize a car license plate by using a PC with 80486-50 CPU. The recognition rate of the system is about 97%. The techniques of CLPR include vehicle sensing, image grab control, optic pre- processing, lighting, and optic character recognition (OCR). The CLPR can be used in vehicle flow statistics, the checking of stolen vehicles, automatic charging systems in parking lots or garage management, and so on.

  3. MyPlate Food Guide

    MedlinePlus

    ... follow throughout your life. 2. Fruits Like veggies, fruits contain vitamins, minerals, and fiber. The red section of MyPlate is slightly smaller than the green, but together fruits and veggies should fill half your plate. Whole ...

  4. What Are Growth Plate Injuries?

    MedlinePlus

    ... activities. Other reasons for growth plate injuries are:  Child abuse  Injury from extreme cold (for example, frostbite)  Radiation ( ... problems) treats most growth plate injuries. At other times, the child will see a pediatric orthopaedic surgeon (a doctor ...

  5. What Are Growth Plate Injuries?

    MedlinePlus

    ... activities. Other reasons for growth plate injuries are: Child abuse Injury from extreme cold (for example, frostbite) Radiation ( ... problems) treats most growth plate injuries. At other times, the child will see a pediatric orthopaedic surgeon (a doctor ...

  6. Design analysis for a nutating plate drive 4

    NASA Technical Reports Server (NTRS)

    Loewenthal, S. H.; Townsend, D. P.

    1972-01-01

    A simplified design analysis was conducted on a nutating plate type drive system for a 2500 horsepower helicopter main rotor gear box. A drive system that split the output torque evenly between two nutating plates for the purpose of reducing the load on each nutating plate was analyzed. Needle bearings were used on the nutating plate pins. The results of the analysis indicate that the required load capacity of the pin bearings and the speed of the nutating plate bearings were beyond the state-of-the-art capacity of rolling-element bearings. The analysis further indicates that the nutating plate drive is less efficient, and results in a higher weight per horsepower than a conventional planetary helicopter transmission with similar design specifications.

  7. Microchannel plate streak camera

    DOEpatents

    Wang, Ching L.

    1989-01-01

    An improved streak camera in which a microchannel plate electron multiplier is used in place of or in combination with the photocathode used in prior streak cameras. The improved streak camera is far more sensitive to photons (UV to gamma-rays) than the conventional x-ray streak camera which uses a photocathode. The improved streak camera offers gamma-ray detection with high temporal resolution. It also offers low-energy x-ray detection without attenuation inside the cathode. Using the microchannel plate in the improved camera has resulted in a time resolution of about 150 ps, and has provided a sensitivity sufficient for 1000 KeV x-rays.

  8. North American plate dynamics

    NASA Technical Reports Server (NTRS)

    Richardson, Randall M.; Reding, Lynn M.

    1991-01-01

    Deformation within the North American plate in response to various tectonic processes is modeled using an elastic finite element analysis. The tectonic processes considered in the modeling include ridge forces associated with the normal thermal evolution of oceanic lithosphere, shear and normal stresses transmitted across transforms, normal stresses transmitted across convergent boundaries, stresses due to horizontal density contrasts within the continent, and shear tractions applied along the base of the plate. Model stresses are calculated with respect to a lithostatic reference stress state. Shear stresses transmitted across transform boundaries along the San Andreas and Caribbean are small, of the order of 5-10 MPa. Also, compressive stresses of the order of 5-10 MPa transmitted across the major transforms improve the fit to the data. Compressive stresses across convergent margins along the Aleutians and the Middle America trench are important.

  9. Microchannel plate streak camera

    DOEpatents

    Wang, C.L.

    1989-03-21

    An improved streak camera in which a microchannel plate electron multiplier is used in place of or in combination with the photocathode used in prior streak cameras is disclosed. The improved streak camera is far more sensitive to photons (UV to gamma-rays) than the conventional x-ray streak camera which uses a photocathode. The improved streak camera offers gamma-ray detection with high temporal resolution. It also offers low-energy x-ray detection without attenuation inside the cathode. Using the microchannel plate in the improved camera has resulted in a time resolution of about 150 ps, and has provided a sensitivity sufficient for 1,000 KeV x-rays. 3 figs.

  10. Microchannel plate streak camera

    DOEpatents

    Wang, C.L.

    1984-09-28

    An improved streak camera in which a microchannel plate electron multiplier is used in place of or in combination with the photocathode used in prior streak cameras. The improved streak camera is far more sensitive to photons (uv to gamma-rays) than the conventional x-ray streak camera which uses a photocathode. The improved streak camera offers gamma-ray detection with high temporal resolution. It also offers low-energy x-ray detection without attenuation inside the cathode. Using the microchannel plate in the improved camera has resulted in a time resolution of about 150 ps, and has provided a sensitivity sufficient for 1000 keV x-rays.

  11. Bipolar battery plate

    NASA Technical Reports Server (NTRS)

    Rowlette, John J. (Inventor)

    1985-01-01

    A liquid-impermeable plate (10) having throughplate conductivity with essentially zero resistance comprises an insulator sheet (12) having a series of spaced perforations (14) each of which contains a metal element (16) sealingly received into the perforation (14). A low-cost plate can readily be manufactured by punching a thermoplastic sheet (40) such as polypropylene with a punching tool (52), filling the apertures with lead spheres (63) having a diameter smaller than the holes (50) but larger than the thickness of the sheet, sweeping excess spheres (62) off the sheet with a doctor blade (60) and then pressing a heated platen (74) onto the sheet to swage the spheres into a cylindrical shape and melt the surrounding resin to form a liquid-impermeable collar (4) sealing the metal into the sheet.

  12. Application of coordinate transform on ball plate calibration

    NASA Astrophysics Data System (ADS)

    Wei, Hengzheng; Wang, Weinong; Ren, Guoying; Pei, Limei

    2015-02-01

    For the ball plate calibration method with coordinate measurement machine (CMM) equipped with laser interferometer, it is essential to adjust the ball plate parallel to the direction of laser beam. It is very time-consuming. To solve this problem, a method based on coordinate transformation between machine system and object system is presented. With the fixed points' coordinates of the ball plate measured in the object system and machine system, the transformation matrix between the coordinate systems is calculated. The laser interferometer measurement data error due to the placement of ball plate can be corrected with this transformation matrix. Experimental results indicate that this method is consistent with the handy adjustment method. It avoids the complexity of ball plate adjustment. It also can be applied to the ball beam calibration.

  13. Plate motion and deformation

    SciTech Connect

    Minster, B.; Prescott, W.; Royden, L.

    1991-02-01

    Our goal is to understand the motions of the plates, the deformation along their boundaries and within their interiors, and the processes that control these tectonic phenomena. In the broadest terms, we must strive to understand the relationships of regional and local deformation to flow in the upper mantle and the rheological, thermal and density structure of the lithosphere. The essential data sets which we require to reach our goal consist of maps of current strain rates at the earth's surface and the distribution of integrated deformation through time as recorded in the geologic record. Our success will depend on the effective synthesis of crustal kinematics with a variety of other geological and geophysical data, within a quantitative theoretical framework describing processes in the earth's interior. Only in this way can we relate the snapshot of current motions and earth structure provided by geodetic and geophysical data with long-term processes operating on the time scales relevant to most geological processes. The wide-spread use of space-based techniques, coupled with traditional geological and geophysical data, promises a revolution in our understanding of the kinematics and dynamics of plate motions over a broad range of spatial and temporal scales and in a variety of geologic settings. The space-based techniques that best address problems in plate motion and deformation are precise space-geodetic positioning -- on land and on the seafloor -- and satellite acquisition of detailed altimetric and remote sensing data in oceanic and continental areas. The overall science objectives for the NASA Solid Earth Science plan for the 1990's, are to Understand the motion and deformation of the lithosphere within and across plate boundaries'', and to understand the dynamics of the mantle, the structure and evolution of the lithosphere, and the landforms that result from local and regional deformation. 57 refs., 7 figs., 2 tabs.

  14. Smov FOS Plate Scale

    NASA Astrophysics Data System (ADS)

    Kinney, Anne

    1994-01-01

    The goal is to measure the precise plate scale and orientation. This will be acheived by performing a raster step and dwell sequence in the 4.3 arcsec aperture. The edges of the aperture should be avoided to prevent vignetting effects. An aperture map is required at each step of the dwell sequence. This test has to be conducted for both the RED and BLUE detectors. We will also determine the offset between the two detectors.

  15. Plated wire memory subsystem

    NASA Technical Reports Server (NTRS)

    Reynolds, L.; Tweed, H.

    1972-01-01

    The work performed entailed the design, development, construction and testing of a 4000 word by 18 bit random access, NDRO plated wire memory for use in conjunction with a spacecraft imput/output unit and central processing unit. The primary design parameters, in order of importance, were high reliability, low power, volume and weight. A single memory unit, referred to as a qualification model, was delivered.

  16. Martian plate tectonics

    NASA Astrophysics Data System (ADS)

    Sleep, N. H.

    1994-03-01

    The northern lowlands of Mars have been produced by plate tectonics. Preexisting old thick highland crust was subducted, while seafloor spreading produced thin lowland crust during late Noachian and Early Hesperian time. In the preferred reconstruction, a breakup margin extended north of Cimmeria Terra between Daedalia Planum and Isidis Planitia where the highland-lowland transition is relatively simple. South dipping subduction occured beneath Arabia Terra and east dipping subduction beneath Tharsis Montes and Tempe Terra. Lineations associated with Gordii Dorsum are attributed to ridge-parallel structures, while Phelegra Montes and Scandia Colles are interpreted as transfer-parallel structures or ridge-fault-fault triple junction tracks. Other than for these few features, there is little topographic roughness in the lowlands. Seafloor spreading, if it occurred, must have been relatively rapid. Quantitative estimates of spreading rate are obtained by considering the physics of seafloor spreading in the lower (approx. 0.4 g) gravity of Mars, the absence of vertical scarps from age differences across fracture zones, and the smooth axial topography. Crustal thickness at a given potential temperature in the mantle source region scales inversely with gravity. Thus, the velocity of the rough-smooth transition for axial topography also scales inversely with gravity. Plate reorganizations where young crust becomes difficult to subduct are another constraint on spreading age. Plate tectonics, if it occurred, dominated the thermal and stress history of the planet. A geochemical implication is that the lower gravity of Mars allows deeper hydrothermal circulation through cracks and hence more hydration of oceanic crust so that more water is easily subducted than on the Earth. Age and structural relationships from photogeology as well as median wavelength gravity anomalies across the now dead breakup and subduction margins are the data most likely to test and modify hypotheses

  17. Elastic plate spallation

    NASA Technical Reports Server (NTRS)

    Oline, L.; Medaglia, J.

    1972-01-01

    The dynamic finite element method was used to investigate elastic stress waves in a plate. Strain displacement and stress strain relations are discussed along with the stiffness and mass matrix. The results of studying point load, and distributed load over small, intermediate, and large radii are reported. The derivation of finite element matrices, and the derivation of lumped and consistent matrices for one dimensional problems with Laplace transfer solutions are included. The computer program JMMSPALL is also included.

  18. Plates with Incompatible Prestrain

    NASA Astrophysics Data System (ADS)

    Bhattacharya, Kaushik; Lewicka, Marta; Schäffner, Mathias

    2016-07-01

    We study effective elastic behavior of the incompatibly prestrained thin plates, where the prestrain is independent of thickness and uniform through the plate's thickness h. We model such plates as three-dimensional elastic bodies with a prescribed pointwise stress-free state characterized by a Riemannian metric G, and seek the limiting behavior as {h to 0}. We first establish that when the energy per volume scales as the second power of h, the resulting {Γ} -limit is a Kirchhoff-type bending theory. We then show the somewhat surprising result that there exist non-immersible metrics G for whom the infimum energy (per volume) scales smaller than h 2. This implies that the minimizing sequence of deformations carries nontrivial residual three-dimensional energy but it has zero bending energy as seen from the limit Kirchhoff theory perspective. Another implication is that other asymptotic scenarios are valid in appropriate smaller scaling regimes of energy. We characterize the metrics G with the above property, showing that the zero bending energy in the Kirchhoff limit occurs if and only if the Riemann curvatures R 1213, R 1223 and R 1212 of G vanish identically. We illustrate our findings with examples; of particular interest is an example where {G_{2 × 2}}, the two-dimensional restriction of G, is flat but the plate still exhibits the energy scaling of the Föppl-von Kármán type. Finally, we apply these results to a model of nematic glass, including a characterization of the condition when the metric is immersible, for {G = Id3 + γ n ⊗ n} given in terms of the inhomogeneous unit director field distribution { n in R^3}.

  19. The Hydrothermal System at Home Plate in Gusev Crater, Mars: Formation of High Silica Material by Acid-Sulfate Alteration of Basalt

    NASA Technical Reports Server (NTRS)

    Morris, R. V.; Ming, D. W.; Gellert, R.; Yen, A.; Clark, B. C.; Gnaff, T. G.; Arvidson, R. E.; Squyres, S. W.

    2008-01-01

    The Alpha Particle X-ray Spectrometer (APXS) instrument on the Mars Exploration Rover (MER) Spirit measured three targets on or adjacent to Home Plate in Gusev Crater that have unusually high SiO2 concentrations (68% to 91%), unusually low FeO concentrations (1% to 7%, with total Fe as FeO), and unusually high TiO2/FeO ratios (0.2 to 1.2 by weight) [1]. Two targets (Kenosha Comets and Lefty Ganote) are located on high albedo soil (Gertrude Weise) that was exposed by the rover wheels, and one target is a float rock called Fuzzy Smith. Kenosha Comets has the highest SiO2 concentration, lowest FeO concentration, and highest TiO2/FeO ratio. Mineralogical evidence from the MER Miniature Thermal Emission Spectrometer (Mini-TES) suggests that the SiO2 is present as amorphous (noncrystalline) SiO2 at Gertrude Weise and nearby targets [2,3]. Mini-TES data were not acquired for Fuzzy Smith. Home Plate is considered to have an explosive volcanic origin, resulting when basaltic magma came into contact with ground water or ice [4]. Within 50 m to 1 km of Home Plate are sulfate rich soil deposits (Paso Robles class soils with 22-35% SO3) which are considered to be probable fumarolic and/or hydrothermal deposits associated with the volcanism [5]. We develop the model here, suggested by [5], that the high-silica materials are another manifestation of acid-sulfate processes associated with fumarolic and hydrothermal activity at Home Plate. This is done by analogy with basaltic materials altered by acid sulfate processes on the Island of Hawaii.

  20. Calibration and equivalency analysis of image plate scanners

    SciTech Connect

    Williams, G. Jackson Maddox, Brian R.; Chen, Hui; Kojima, Sadaoki; Millecchia, Matthew

    2014-11-15

    A universal procedure was developed to calibrate image plate scanners using radioisotope sources. Techniques to calibrate scanners and sources, as well as cross-calibrate scanner models, are described to convert image plate dosage into physical units. This allows for the direct comparison of quantitative data between any facility and scanner. An empirical relation was also derived to establish sensitivity response settings for arbitrary gain settings. In practice, these methods may be extended to any image plate scanning system.

  1. Calibration and equivalency analysis of image plate scanners.

    PubMed

    Williams, G Jackson; Maddox, Brian R; Chen, Hui; Kojima, Sadaoki; Millecchia, Matthew

    2014-11-01

    A universal procedure was developed to calibrate image plate scanners using radioisotope sources. Techniques to calibrate scanners and sources, as well as cross-calibrate scanner models, are described to convert image plate dosage into physical units. This allows for the direct comparison of quantitative data between any facility and scanner. An empirical relation was also derived to establish sensitivity response settings for arbitrary gain settings. In practice, these methods may be extended to any image plate scanning system. PMID:25430350

  2. Computational models for the nonlinear analysis of reinforced concrete plates

    NASA Technical Reports Server (NTRS)

    Hinton, E.; Rahman, H. H. A.; Huq, M. M.

    1980-01-01

    A finite element computational model for the nonlinear analysis of reinforced concrete solid, stiffened and cellular plates is briefly outlined. Typically, Mindlin elements are used to model the plates whereas eccentric Timoshenko elements are adopted to represent the beams. The layering technique, common in the analysis of reinforced concrete flexural systems, is incorporated in the model. The proposed model provides an inexpensive and reasonably accurate approach which can be extended for use with voided plates.

  3. The Philippine Sea Plate: Magnetism and reconstructions

    NASA Astrophysics Data System (ADS)

    Hall, Robert; Fuller, Michael; Ali, Jason R.; Anderson, Charles D.

    Paleomagnetic results from ocean drilling and from land on the Philippine Sea Plate indicate progressive northward translation of the entire plate during the Tertiary, although different sites suggest different ages of equatorial crossing. The difficulty of orienting ocean drilling cores has recently been remedied and Ocean Drilling Program leg 126 provided the first Philippine Sea Plate declination data from sea bottom sites. These showed large clockwise declination shifts of up to -90° since the early Oligocene. Similar large declination shifts have been reported from land sites at the eastern margin of the plate; these record similar changes in inclinations with age as ocean drilling sites. The cause of the declination deflections is controversial and they have been explained as the result of entire plate rotation, marginal basin opening, and/or local tectonic deformation at the plate edge. Because most declination data have been obtained from the eastern margin of the plate, it has proved impossible to distinguish between these three possible causes. However, new paleomagnetic data from land sites in the southern part of the Philippine Sea Plate in eastern Indonesia define two sub-areas: a region within the Sorong fault system that records variable rotations attributed to deformation at the plate edge, and a region north of the Sorong fault that records a large Tertiary, but discontinuous, clockwise rotation. Both areas record northward paleolatitude shifts with decreasing age since the beginning of the Neogene but inclinations of lower Eocene sites suggest southward movement during the Paleogene. We consider the area north of the Sorong fault to form one of the oldest parts of the plate and assume that the declination shifts record the Tertiary rotation of the western part of the plate. Using this assumption it is possible to calculate rotation poles and reconstruct the Philippine Sea Plate after calculating the rotational effects of opening the marginal

  4. Origin of Small Tectonic Plates

    NASA Astrophysics Data System (ADS)

    Mallard, C.; Coltice, N.; Seton, M.; Müller, D.; Tackley, P.

    2015-12-01

    The plate tectonic theory allowed to split the Earth surface into 6 (Le Pichon 1968) to 52 tectonic plates (Bird 2003). These plates are separated into two groups: the first of 7 large plates and the second of numerous smaller plates (Morra et al 2013). Previous studies using the reconstruction of the past 200 My, suggest that the size of large plates is driven by mantle flow. But the tools employed are descriptive (Morra et al 2013, Sornette and Pisarenko 2003), hence ignoring forces and physical principles within the lithosphere and the mantle. The processes at the origin of small plates remain unknown. We developed a new approach to explain the plate sizes. We demonstrate that the physics of convection drives it. We applied plate tectonics theory on 3D spherical convection models generating plate-like motions, which give access to a complete survey of data: velocities, viscosity and heat flow. Our data show that (1) the large plates depend on the dominating scale of the convective flow due to the initiation or the shutdown of subductions; (2) the smaller plates are generated thanks to large variability of regional stresses along subduction zone by slab pull and suction influenced by the geometry of trenches. Our results are consistent with the quick reorganizations of back-arc basins occuring synchronously with the modification of subduction zones geometry around the Pacific plate (Sdrolias et al 2004). Hence, we conclude that (1) the decreasing number of small plates in the plate reconstructions back in time is an artifact induced by their short lifetime, that is why they are artificially ignored; (2) the geometry of past trenches is simplified leading to an underestimation of the length of subduction zones.

  5. A cell-based sensor system for toxicity testing using multiwavelength fluorescence spectroscopy.

    PubMed

    Fritzsche, Michael; Fredriksson, J Magnus; Carlsson, Maria; Mandenius, Carl-Fredrik

    2009-04-15

    A novel cell-based fluorometric sensor system for toxicity monitoring is described, which uses functional spontaneously contracting cardiomyocytes (HL-1 cell line) as the biological recognition element. Based on these highly specialized cells, it has the potential of providing a sensitive and relevant analytical in vitro toxicity testing method. The system was configured by propagating the surface-attaching HL-1 cardiomyocytes in the wells of a 96-well microtiter plate and connecting the plate via an optical fiber to a fluorescence spectrometer capable of excitation-emission matrix scanning. The fluorescence data were analyzed using a conventional spectral analysis software program. The performance of the system for detection of general cytotoxicity to the cells was evaluated using three well-known drugs: verapamil, quinidine, and acetaminophen. The dose-response curves were assessed and the EC(50) values were determined (0.10+/-0.007, 0.23+/-0.025, and 12.32+/-2.40 mM, respectively). Comparison with in vitro and in vivo reference data for the drugs showed good correlations, suggesting that this cell-based sensor system could be a useful tool in pharmacological in vitro drug testing. PMID:19454238

  6. Plate tectonics conserves angular momentum

    NASA Astrophysics Data System (ADS)

    Bowin, C.

    2009-03-01

    A new combined understanding of plate tectonics, Earth internal structure, and the role of impulse in deformation of the Earth's crust is presented. Plate accelerations and decelerations have been revealed by iterative filtering of the quaternion history for the Euler poles that define absolute plate motion history for the past 68 million years, and provide an unprecedented precision for plate angular rotation variations with time at 2-million year intervals. Stage poles represent the angular rotation of a plate's motion between adjacent Euler poles, and from which the maximum velocity vector for a plate can be determined. The consistent maximum velocity variations, in turn, yield consistent estimates of plate accelerations and decelerations. The fact that the Pacific plate was shown to accelerate and decelerate, implied that conservation of plate tectonic angular momentum must be globally conserved, and that is confirmed by the results shown here (total angular momentum ~1.4 E+27 kgm2s-1). Accordingly, if a plate decelerates, other plates must increase their angular momentums to compensate. In addition, the azimuth of the maximum velocity vectors yields clues as to why the "bend" in the Emperor-Hawaiian seamount trend occurred near 46 Myr. This report summarizes processing results for 12 of the 14 major tectonic plates of the Earth (except for the Juan de Fuca and Philippine plates). Plate accelerations support the contention that plate tectonics is a product of torques that most likely are sustained by the sinking of positive density anomalies due to phase changes in subducted gabbroic lithosphere at depth in the upper lower mantle (above 1200 km depth). The tectonic plates are pulled along by the sinking of these positive mass anomalies, rather than moving at near constant velocity on the crests of convection cells driven by rising heat. These results imply that spreading centers are primarily passive reactive features, and fracture zones (and wedge-shaped sites

  7. Symmetries in laminated composite plates

    NASA Technical Reports Server (NTRS)

    Noor, A. K.

    1976-01-01

    The different types of symmetry exhibited by laminated anisotropic fibrous composite plates are identified and contrasted with the symmetries of isotropic and homogeneous orthotropic plates. The effects of variations in the fiber orientation and the stacking sequence of the layers on the symmetries exhibited by composite plates are discussed. Both the linear and geometrically nonlinear responses of the plates are considered. A simple procedure is presented for exploiting the symmetries in the finite element analysis. Examples are given of square, skew and polygonal plates where use of symmetry concepts can significantly reduce the scope and cost of analysis.

  8. Fuel cell end plate structure

    DOEpatents

    Guthrie, Robin J.; Katz, Murray; Schroll, Craig R.

    1991-04-23

    The end plates (16) of a fuel cell stack (12) are formed of a thin membrane. Pressure plates (20) exert compressive load through insulation layers (22, 26) to the membrane. Electrical contact between the end plates (16) and electrodes (50, 58) is maintained without deleterious making and breaking of electrical contacts during thermal transients. The thin end plate (16) under compressive load will not distort with a temperature difference across its thickness. Pressure plate (20) experiences a low thermal transient because it is insulated from the cell. The impact on the end plate of any slight deflection created in the pressure plate by temperature difference is minimized by the resilient pressure pad, in the form of insulation, therebetween.

  9. A titer plate-based polymer microfluidic platform for high throughput nucleic acid purification.

    PubMed

    Park, D S-W; Hupert, M L; Witek, M A; You, B H; Datta, P; Guy, J; Lee, J-B; Soper, S A; Nikitopoulos, D E; Murphy, M C

    2008-02-01

    A 96-well solid-phase reversible immobilization (SPRI) reactor plate was designed to demonstrate functional titer plate-based microfluidic platforms. Nickel, large area mold inserts were fabricated using an SU-8 based, UV-LIGA technique on 150 mm diameter silicon substrates. Prior to UV exposure, the prebaked SU-8 resist was flycut to reduce the total thickness variation to less than 5 mum. Excellent UV lithography results, with highly vertical sidewalls, were obtained in the SU-8 by using an UV filter to remove high absorbance wavelengths below 350 nm. Overplating of nickel in the SU-8 patterns produced high quality, high precision, metal mold inserts, which were used to replicate titer plate-based SPRI reactors using hot embossing of polycarbonate (PC). Optimized molding conditions yielded good feature replication fidelity and feature location integrity over the entire surface area. Thermal fusion bonding of the molded PC chips at 150 degrees C resulted in leak-free sealing, which was verified in leakage tests using a fluorescent dye. The assembled SPRI reactor was used for simple, fast purification of genomic DNA from whole cell lysates of several bacterial species, which was verified by PCR amplification of the purified genomic DNA. PMID:17659445

  10. Optimization of Salmonella Typhi biofilm assay on polypropylene microtiter plates using response surface methodology.

    PubMed

    Ganjali Dashti, M; Abdeshahian, P; Sudesh, K; Phua, K K

    2016-04-01

    The objective of this study was to develop an optimized assay for Salmonella Typhi biofilm that mimics the environment of the gallbladder as an experimental model for chronic typhoid fever. Multi-factorial assays are difficult to optimize using traditional one-factor-at-a-time optimization methods. Response surface methodology (RSM) was used to optimize six key variables involved in S. Typhi biofilm formation on cholesterol-coated polypropylene 96-well microtiter plates. The results showed that bile (1.22%), glucose (2%), cholesterol (0.05%) and potassium chloride (0.25%) were critical factors affecting the amount of biofilm produced, but agitation (275 rpm) and sodium chloride (0.5%) had antagonistic effects on each other. Under these optimum conditions the maximum OD reading for biofilm formation was 3.4 (λ600 nm), and the coefficients of variation for intra-plate and inter-plate assays were 3% (n = 20) and 5% (n = 8), respectively. These results showed that RSM is an effective approach for biofilm assay optimization. PMID:26963754

  11. A unidirectional subwavelength focusing near-field plate

    SciTech Connect

    Imani, Mohammadreza F.; Grbic, Anthony

    2014-01-28

    Near-field plates consist of non-periodically patterned surfaces that can overcome the diffraction limit and confine electromagnetic fields to subwavelength dimensions. Previous near-field plates experimentally demonstrated extreme field tailoring capabilities. However, their performance suffered from radiation/reflection in undesired directions, those other than the subwavelength focus. This issue can limit the practical use of near-field plates. In this paper, we address this issue by designing a unidirectional near-field plate that can form a subwavelength focal pattern, while suppressing the field radiated/reflected in other directions. The design and operation of the proposed unidirectional near-field plate are verified through full-wave simulation. The unidirectional near-field plate may find application in high resolution imaging and probing, high density data storage, and wireless power transfer systems. As an example, its utility as a high resolution probe is demonstrated through full-wave electromagnetic simulation.

  12. Geometrically nonlinear vibrations of rectangular plates carrying a concentrated mass

    NASA Astrophysics Data System (ADS)

    Amabili, M.

    2010-10-01

    Nonlinear forced vibrations of rectangular plates carrying a central concentrated mass are studied. The plate is assumed to have immovable edges and rotational springs; numerical results are presented for clamped plates. The Von Kármán nonlinear plate theory is used, but in-plane inertia in both the plate and the mass is retrained. The problem is discretized into a multi-degree-of-freedom (dof) system by using an energy approach and Lagrange equations taking damping into account. A pseudo-arclength continuation method is used in order to obtain numerical solutions. Results are presented as both (i) frequency-amplitude curves and (ii) time domain responses. The effect of gravity and the effect of the consequent initial plate deflection are also investigated.

  13. Physical optics for oven-plate scattering prediction

    NASA Technical Reports Server (NTRS)

    Baldauf, J.; Lambert, K.

    1991-01-01

    An oven assembly design is described, which will be used to determine the effects of temperature on the electrical properties of materials which are used as coatings for metal plates. Experimentally, these plates will be heated to a very high temperature in the oven assembly, and measured using a microwave reflectance measurement system developed for the NASA Lewis Research Center, Near-Field Facility. One unknown in this measurement is the effect that the oven assembly will have on the reflectance properties of the plate. Since the oven will be much larger than the plate, the effect could potentially be significant as the size of the plate becomes smaller. Therefore, it is necessary to predict the effect of the oven on the measurement of the plate. A method for predicting the oven effect is described, and the theoretical oven effect is compared to experimental results of the oven material. The computer code which is used to predict the oven effect is also described.

  14. Comparison of treatment of unstable intra articular fractures of distal radius with locking plate versus non-locking plate fixation

    PubMed Central

    Kumar, Sunil; Chopra, R.K.; Sehrawat, Sunil; Lakra, Akshay

    2014-01-01

    Introduction Unstable intra articular fractures of distal radius are frequently being managed with open reduction and internal fixation. Of late in some biomechanical studies locking plates have been shown to be better in terms of maintenance of radiological parameters in comparison to non-locking plates. We conducted this study to know whether this biomechanical superiority of locking plates is converted in to better clinical outcomes. Materials and methods A study was conducted in 60 patients (30 in each group) with unstable intra articular fractures of distal radius who were treated by open reduction and internal fixation with locking plates and non-locking plates. Patients were evaluated for radiological parameters (intra articular step off, radial height, radial tilt, volar tilt) and functional parameters (flexion, extension, radial deviation, ulnar deviation, pronation, supination grip strength) at two year follow up. Overall outcome was evaluated by scoring systems of Gartland and Werley and modified Green O' Brien. Results The change in radiological parameters from immediate post op to latest at two year in locking plate group was not significant for radial height, radial tilt, volar tilt, but ulnar variance whereas in non-locking plate there was significant change in radial height, volar tilt, ulnar variance but no significant change in radial inclination. In clinical and functional outcome no significant difference was found at two year follow up. Conclusions Locking plates maintain the radiological parameters better than non-locking plates but functional outcome are same for both plates at two year after surgery. PMID:25983474

  15. Wobble plate engine

    SciTech Connect

    Derderian, H.; Pronovost, J.

    1980-07-01

    A description is given of a conventional Stirling cycle engine of the type characterized by an elongated cylinder having a closed end and an open end, means for applying heat to the exterior of the cylinder to heat gas in the interior of the cylinder at the closed end thereof, a displacer piston mounted for a reciprocation within the closed end of the cylinder and a power piston axially aligned with the displacer piston and mounted for coaxial reciprocation between the displacer piston and the open end of the cylinder, the reciprocation of the displacer piston leading the corresponding stroke of the power piston by a predetermined phase angle, the improved means for properly phasing the reciprocation of the two pistons and for converting the reciprocation of the power piston into rotation of an output shaft which is parallel to the axis of reciprocation comprising: a supporting frame; an output shaft mounted on said frame for rotation about a first axis which is parallel to the axis of reciprocation of the two pistons, said shaft having an inclined cylindrical bearing surface the axis of which intersects said first axis at an acute angle; gimbal means pivotally mounted on said supporting frame for oscillation about a second axis perpendicular to and intersecting first axis; a wobble plate pivotally mounted on a third axis within said gimbal means for oscillation with said gimbal means and for further oscillation about said third axis which is mutually perpendicular to and intersecting said first and second axes, said wobble plate being rotatably mounted on said inclined cylindrical bearing surface in a plane which is perpendicular to said axis of said bearing surface whereby said output shaft can rotate about said first axis as said wobble plate oscillates about said second and third axes.

  16. EVAPORATIVE RECOVERY OF CHROMIUM PLATING RINSE WATERS

    EPA Science Inventory

    This demonstration project documents the practicality of a new evaporative approach for recovering chromic acid from metal finishing rinse waste waters, as well as the economics of the system under actual operating conditions. The six-month study of chrome plating operations was ...

  17. Shuttle plate braiding machine

    NASA Technical Reports Server (NTRS)

    Huey, Jr., Cecil O. (Inventor)

    1994-01-01

    A method and apparatus for moving yarn in a selected pattern to form a braided article. The apparatus includes a segmented grid of stationary support elements and a plurality of shuttles configured to carry yarn. The shuttles are supported for movement on the grid assembly and each shuttle includes a retractable plunger for engaging a reciprocating shuttle plate that moves below the grid assembly. Such engagement at selected times causes the shuttles to move about the grid assembly in a selected pattern to form a braided article of a particular geometry.

  18. Ultrafast microchannel plate photomultipliers.

    PubMed

    Kume, H; Koyama, K; Nakatsugawa, K; Suzuki, S; Fatlowitz, D

    1988-03-15

    Performance characteristics of several new types of photomultiplier tubes (PMT) with microchannel plates (MCP) are presented in this paper. They are the MCP-PMT with 6-microm diam channels, MCP-PMT with an S-l photocathode, and MCP-PMT with multi (discrete) anode and gatable MCP-PMT. Important requirements of an optical detector for picosecond lasers, fluorescence measurements, and material analysis are low light detectability, ultrafast time response, and versatile operation including modulation. The basic configuration, characteristics, and practical results of these detectors are described. PMID:20531532

  19. Rotary sequencing valve with flexible port plate

    DOEpatents

    Wagner, Glenn Paul

    2005-05-10

    Rotary sequencing valve comprising a rotor having a rotor face rotatable about an axis perpendicular to the rotor face, wherein the rotor face has a plurality of openings, one or more of which are disposed at a selected radial distance from the axis, and wherein the rotor includes at least one passage connecting at least one pair of the plurality of openings. The valve includes a flexible port plate having a first side and a second side, wherein the first side faces the rotor and engages the rotor such that the flexible port plate can be rotated coaxially by the rotor and can move axially with respect to the rotor, wherein the flexible port plate has a plurality of ports between the first and second sides, which ports are aligned with the openings in the rotor face. The valve also includes a stator having a stator face disposed coaxially with the rotor and the flexible port plate, wherein the second side of the flexible port plate is in sealable, slidable rotary contact with the stator face, wherein the stator face has a plurality of openings, some of which are disposed at the selected radial distance from the axis, and wherein the plurality of openings extend as passages through the stator. The valve may be used in pressure or temperature swing adsorption systems.

  20. Fuel Cell Thermal Management Through Conductive Cooling Plates

    NASA Technical Reports Server (NTRS)

    Colozza, Anthony J.; Burke, Kenneth A.

    2008-01-01

    An analysis was performed to evaluate the concept of utilizing conductive cooling plates to remove heat from a fuel cell stack, as opposed to a conventional internal cooling loop. The potential advantages of this type of cooling system are reduced stack complexity and weight and increased reliability through the reduction of the number of internal fluid seals. The conductive cooling plates would extract heat from the stack transferring it to an external coolant loop. The analysis was performed to determine the required thickness of these plates. The analysis was based on an energy balance between the thermal energy produced within the stack and the heat removal from the cooling plates. To accomplish the energy balance, the heat flow into and along the plates to the cooling fluid was modeled. Results were generated for various numbers of cells being cooled by a single cooling plate. The results provided cooling plate thickness, mass, and operating temperature of the plates. It was determined that utilizing high-conductivity pyrolitic graphite cooling plates can provide a specific cooling capacity (W/kg) equivalent to or potentially greater than a conventional internal cooling loop system.

  1. Low-distortion resistive anodes for two-dimensional position-sensitive MCP systems. [Microchannel Plates for ion, electron and photon image sensing and conversion

    NASA Technical Reports Server (NTRS)

    Lampton, M.; Carlson, C. W.

    1979-01-01

    Microchannel plates (MCPs) are frequently used with resistive anodes to detect charged particles or photons and yield analog signals from which event positions can be decoded. The paper discusses a four-corner concave circular arc terminated resistive anode that permits theoretically distortionless encoding of Cartesian event positions into pulse charge ratios. The theory of the circular arc terminated anode is discussed along with anode design and performance. Electron beam images obtained by using such an anode are presented to confirm the usefulness of the approach.

  2. Astrometric properties of the Tautenburg Plate Scanner

    NASA Astrophysics Data System (ADS)

    Brunzendorf, Jens; Meusinger, Helmut

    The Tautenburg Plate Scanner (TPS) is an advanced plate-measuring machine run by the Thüringer Landessternwarte Tautenburg (Karl Schwarzschild Observatory), where the machine is housed. It is capable of digitising photographic plates up to 30 cm × 30 cm in size. In our poster, we reported on tests and preliminary results of its astrometric properties. The essential components of the TPS consist of an x-y table movable between an illumination system and a direct imaging system. A telecentric lens images the light transmitted through the photographic emulsion onto a CCD line of 6000 pixels of 10 µm square size each. All components are mounted on a massive air-bearing table. Scanning is performed in lanes of up to 55 mm width by moving the x-y table in a continuous drift-scan mode perpendicular to the CCD line. The analogue output from the CCD is digitised to 12 bit with a total signal/noise ratio of 1000 : 1, corresponding to a photographic density range of three. The pixel map is produced as a series of optionally overlapping lane scans. The pixel data are stored onto CD-ROM or DAT. A Tautenburg Schmidt plate 24 cm × 24 cm in size is digitised within 2.5 hours resulting in 1.3 GB of data. Subsequent high-level data processing is performed off-line on other computers. During the scanning process, the geometry of the optical components is kept fixed. The optimal focussing of the optics is performed prior to the scan. Due to the telecentric lens refocussing is not required. Therefore, the main source of astrometric errors (beside the emulsion itself) are mechanical imperfections in the drive system, which have to be divided into random and systematic ones. The r.m.s. repeatability over the whole plate as measured by repeated scans of the same plate is about 0.5 µm for each axis. The mean plate-to-plate accuracy of the object positions on two plates with the same epoch and the same plate centre has been determined to be about 1 µm. This accuracy is comparable to

  3. Plate tectonics drive tropical reef biodiversity dynamics

    PubMed Central

    Leprieur, Fabien; Descombes, Patrice; Gaboriau, Théo; Cowman, Peter F.; Parravicini, Valeriano; Kulbicki, Michel; Melián, Carlos J.; de Santana, Charles N.; Heine, Christian; Mouillot, David; Bellwood, David R.; Pellissier, Loïc

    2016-01-01

    The Cretaceous breakup of Gondwana strongly modified the global distribution of shallow tropical seas reshaping the geographic configuration of marine basins. However, the links between tropical reef availability, plate tectonic processes and marine biodiversity distribution patterns are still unknown. Here, we show that a spatial diversification model constrained by absolute plate motions for the past 140 million years predicts the emergence and movement of diversity hotspots on tropical reefs. The spatial dynamics of tropical reefs explains marine fauna diversification in the Tethyan Ocean during the Cretaceous and early Cenozoic, and identifies an eastward movement of ancestral marine lineages towards the Indo-Australian Archipelago in the Miocene. A mechanistic model based only on habitat-driven diversification and dispersal yields realistic predictions of current biodiversity patterns for both corals and fishes. As in terrestrial systems, we demonstrate that plate tectonics played a major role in driving tropical marine shallow reef biodiversity dynamics. PMID:27151103

  4. Plate tectonics drive tropical reef biodiversity dynamics.

    PubMed

    Leprieur, Fabien; Descombes, Patrice; Gaboriau, Théo; Cowman, Peter F; Parravicini, Valeriano; Kulbicki, Michel; Melián, Carlos J; de Santana, Charles N; Heine, Christian; Mouillot, David; Bellwood, David R; Pellissier, Loïc

    2016-01-01

    The Cretaceous breakup of Gondwana strongly modified the global distribution of shallow tropical seas reshaping the geographic configuration of marine basins. However, the links between tropical reef availability, plate tectonic processes and marine biodiversity distribution patterns are still unknown. Here, we show that a spatial diversification model constrained by absolute plate motions for the past 140 million years predicts the emergence and movement of diversity hotspots on tropical reefs. The spatial dynamics of tropical reefs explains marine fauna diversification in the Tethyan Ocean during the Cretaceous and early Cenozoic, and identifies an eastward movement of ancestral marine lineages towards the Indo-Australian Archipelago in the Miocene. A mechanistic model based only on habitat-driven diversification and dispersal yields realistic predictions of current biodiversity patterns for both corals and fishes. As in terrestrial systems, we demonstrate that plate tectonics played a major role in driving tropical marine shallow reef biodiversity dynamics. PMID:27151103

  5. Plate tectonics drive tropical reef biodiversity dynamics

    NASA Astrophysics Data System (ADS)

    Leprieur, Fabien; Descombes, Patrice; Gaboriau, Théo; Cowman, Peter F.; Parravicini, Valeriano; Kulbicki, Michel; Melián, Carlos J.; de Santana, Charles N.; Heine, Christian; Mouillot, David; Bellwood, David R.; Pellissier, Loïc

    2016-05-01

    The Cretaceous breakup of Gondwana strongly modified the global distribution of shallow tropical seas reshaping the geographic configuration of marine basins. However, the links between tropical reef availability, plate tectonic processes and marine biodiversity distribution patterns are still unknown. Here, we show that a spatial diversification model constrained by absolute plate motions for the past 140 million years predicts the emergence and movement of diversity hotspots on tropical reefs. The spatial dynamics of tropical reefs explains marine fauna diversification in the Tethyan Ocean during the Cretaceous and early Cenozoic, and identifies an eastward movement of ancestral marine lineages towards the Indo-Australian Archipelago in the Miocene. A mechanistic model based only on habitat-driven diversification and dispersal yields realistic predictions of current biodiversity patterns for both corals and fishes. As in terrestrial systems, we demonstrate that plate tectonics played a major role in driving tropical marine shallow reef biodiversity dynamics.

  6. 30 CFR 27.7 - Certification plate or label.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Certification plate or label. 27.7 Section 27.7 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS METHANE-MONITORING SYSTEMS General Provisions § 27.7 Certification plate or label. A certified...

  7. 46 CFR 64.53 - Information plate for MPTs.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 2 2011-10-01 2011-10-01 false Information plate for MPTs. 64.53 Section 64.53 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING MARINE PORTABLE TANKS AND CARGO HANDLING SYSTEMS Standards for an MPT § 64.53 Information plate for MPTs. (a) A...

  8. Tectonics of the Easter plate

    NASA Technical Reports Server (NTRS)

    Engeln, J. F.; Stein, S.

    1984-01-01

    A new model for the Easter plate is presented in which rift propagation has resulted in the formation of a rigid plate between the propagating and dying ridges. The distribution of earthquakes, eleven new focal mechanisms, and existing bathymetric and magnetic data are used to describe the tectonics of this area. Both the Easter-Nazca and Easter-Pacific Euler poles are sufficiently close to the Easter plate to cause rapid changes in rates and directions of motion along the boundaries. The east and west boundaries are propagating and dying ridges; the southwest boundary is a slow-spreading ridge and the northern boundary is a complex zone of convergent and transform motion. The Easter plate may reflect the tectonics of rift propagation on a large scale, where rigid plate tectonics requires boundary reorientation. Simple schematic models to illustrate the general features and processes which occur at plates resulting from large-scale rift propagation are used.

  9. Localised Plate Motion on Venus

    NASA Astrophysics Data System (ADS)

    Ghail, R. C.

    1996-03-01

    The volcanic and tectonic features observed in Dali Vinculum, Parga Vinculum and Imdr Regio are concentrated at long, narrow, curvilinear zones, with relatively minor volcanism and tectonism between these zones. These zones, whilst more diffuse than terrestrial plate boundaries, nevertheless define the margins of tectonic plates. In contrast to Earth, however, it appears that venusian plates are neither created nor destroyed by lateral motion. Rather, plates are thinned and intruded at vincula plate boundaries, vertically accreted by small-scale intra-plate (planitia) volcanism and perhaps destroyed by delamination of thickened crust in tesserae and montane regions such as Thetis Regio and Ishtar Terra. The diversity in age both between and within these three areas together with the evidence for infrequent, small scale resurfacing in the planitiae are difficult to reconcile with a non-uniformitarian geological process.

  10. Channel plate for DNA sequencing

    DOEpatents

    Douthart, R.J.; Crowell, S.L.

    1998-01-13

    This invention is a channel plate that facilitates data compaction in DNA sequencing. The channel plate has a length, a width and a thickness, and further has a plurality of channels that are parallel. Each channel has a depth partially through the thickness of the channel plate. Additionally an interface edge permits electrical communication across an interface through a buffer to a deposition membrane surface. 15 figs.

  11. Ion plating for the future

    NASA Technical Reports Server (NTRS)

    Spalvins, T.

    1981-01-01

    The ion plating techniques are classified relative to the instrumental set up, evaporation media, and mode of transport. A distinction is drawn between the low vacuum (plasma) and high vacuum (ion beam) techniques. Ion plating technology is discussed at the fundamental and industrial level. At the fundamental level, the capabilities and limitations of the plasma (evaporant flux) and film characteristics are evaluated. And on the industrial level, the performance and potential uses of ion plated films are discussed.

  12. Channel plate for DNA sequencing

    DOEpatents

    Douthart, Richard J.; Crowell, Shannon L.

    1998-01-01

    This invention is a channel plate that facilitates data compaction in DNA sequencing. The channel plate has a length, a width and a thickness, and further has a plurality of channels that are parallel. Each channel has a depth partially through the thickness of the channel plate. Additionally an interface edge permits electrical communication across an interface through a buffer to a deposition membrane surface.

  13. The StarScan Plate Measuring Machine: Overview and Calibrations

    NASA Astrophysics Data System (ADS)

    Zacharias, N.; Winter, L.; Holdenried, E. R.; De Cuyper, J.-P.; Rafferty, T. J.; Wycoff, G. L.

    2008-06-01

    The StarScan machine at the U.S. Naval Observatory (USNO) completed measuring photographic astrograph plates to allow determination of proper motions for the USNO CCD Astrograph Catalog (UCAC) program. All applicable 1940 AGK2 plates, about 2200 Hamburg Zone Astrograph plates, 900 Black Birch (USNO Twin Astrograph) plates, and 300 Lick Astrograph plates have been measured. StarScan comprises a CCD camera, a telecentric lens, an air-bearing granite table, stepper motor screws, and Heidenhain scales to operate in a step-stare mode. The repeatability of StarScan measures is about 0.2 μm. The CCD mapping as well as the global table coordinate system has been calibrated using a special dot calibration plate and the overall accuracy of StarScan x, y data is derived to be 0.5 μm. Application to real photographic plate data shows that position information of at least 0.65 μm accuracy can be extracted from coarse-grain 103a-type emulsion astrometric plates. Transformations between "direct" and "reverse" measures of fine-grain emulsion plate measures are obtained on the 0.3 μm level per well-exposed stellar image and coordinate, a level that is at the limit of the StarScan machine.

  14. On electrostatically actuated NEMS/MEMS circular plates

    NASA Astrophysics Data System (ADS)

    Caruntu, Dumitru I.; Alvarado, Iris

    2011-04-01

    This paper deals with electrostatically actuated micro and nano-electromechanical (MEMS/NEMS) circular plates. The system under investigation consists of two bodies, a deformable and conductive circular plate placed above a fixed, rigid and conductive ground plate. The deformable circular plate is electrostatically actuated by applying an AC voltage between the two plates. Nonlinear parametric resonance and pull-in occur at certain frequencies and relatively large AC voltage, respectively. Such phenomena are useful for applications such as sensors, actuators, switches, micro-pumps, micro-tweezers, chemical and mass sensing, and micro-mirrors. A mathematical model of clamped circular MEMS/NEMS electrostatically actuated plates has been developed. Since the model is in the micro- and nano-scale, surface forces, van der Waals and/or Casimir, acting on the plate are included. A perturbation method, the Method of Multiple Scales (MMS), is used for investigating the case of weakly nonlinear MEMS/NEMS circular plates. Two time scales, fast and slow, are considered in this work. The amplitude-frequency and phase-frequency response of the plate in the case of primary resonance are obtained and discussed.

  15. Carbon-assisted flyer plates

    DOEpatents

    Stahl, David B.; Paisley, Dennis L.

    1994-01-01

    A laser driven flyer plate utilizing an optical fiber connected to a laser. The end of the optical fiber has a layer of carbon and a metal layer deposited onto it. The carbon layer provides the laser induced plasma which is superior to the plasma produced from most metals. The carbon layer plasma is capable of providing a flatter flyer plate, converting more of the laser energy to driving plasma, promoting a higher flyer plate acceleration, and providing a more uniform pulse behind the plate. In another embodiment, the laser is in optical communication with a substrate onto which a layer of carbon and a layer of metal have been deposited.

  16. True Shear Parallel Plate Viscometer

    NASA Technical Reports Server (NTRS)

    Ethridge, Edwin; Kaukler, William

    2010-01-01

    This viscometer (which can also be used as a rheometer) is designed for use with liquids over a large temperature range. The device consists of horizontally disposed, similarly sized, parallel plates with a precisely known gap. The lower plate is driven laterally with a motor to apply shear to the liquid in the gap. The upper plate is freely suspended from a double-arm pendulum with a sufficiently long radius to reduce height variations during the swing to negligible levels. A sensitive load cell measures the shear force applied by the liquid to the upper plate. Viscosity is measured by taking the ratio of shear stress to shear rate.

  17. Glass-bead peen plating

    NASA Technical Reports Server (NTRS)

    Graves, J. R.

    1974-01-01

    Peen plating of aluminum, copper, and nickel powders was investigated. Only aluminum was plated successfully within the range of peen plating conditions studied. Optimum plating conditions for aluminum were found to be: (1) bead/powder mixture containing 25 to 35% powder by weight, (2) peening intensity of 0.007A as measured by Almen strip, and (3) glass impact bead diameter of at least 297 microns (0.0117 inches) for depositing-100 mesh aluminum powder. No extensive cleaning or substrate preparation is required beyond removing loose dirt or heavy oil.

  18. Laser-driven flyer plate

    SciTech Connect

    Paisley, D.L.

    1991-09-10

    Disclosed is an apparatus for producing high velocity flyer plates involving placing a layer of dielectric material between a first metal foil and a second metal foil. With laser irradiation through an optical substrate, the first metal foil forms a plasma in the area of the irradiation, between the substrate and the solid portion of the first metal foil. When the pressure between the substrate and the foil reaches the stress limit of the dielectric, the dielectric will break away and launch the flyer plate out of the second metal foil. The mass of the flyer plate is controlled, as no portion of the flyer plate is transformed into a plasma. 2 figures.

  19. Laser-driven flyer plate

    DOEpatents

    Paisley, Dennis L.

    1991-01-01

    Apparatus for producing high velocity flyer plates involving placing a layer of dielectric material between a first metal foil and a second metal foil. With laser irradiation through an optical substrate, the first metal foil forms a plasma in the area of the irradiation, between the substrate and the solid portion of the first metal foil. When the pressure between the substrate and the foil reaches the stress limit of the dielectric, the dielectric will break away and launch the flyer plate out of the second metal foil. The mass of the flyer plate is controlled, as no portion of the flyer plate is transformed into a plasma.

  20. Scintillator plate calorimetry

    SciTech Connect

    Price, L.E.

    1990-01-01

    Calorimetry using scintillator plates or tiles alternated with sheets of (usually heavy) passive absorber has been proven over multiple generations of collider detectors. Recent detectors including UA1, CDF, and ZEUS have shown good results from such calorimeters. The advantages offered by scintillator calorimetry for the SSC environment, in particular, are speed (<10 nsec), excellent energy resolution, low noise, and ease of achieving compensation and hence linearity. On the negative side of the ledger can be placed the historical sensitivity of plastic scintillators to radiation damage, the possibility of nonuniform response because of light attenuation, and the presence of cracks for light collection via wavelength shifting plastic (traditionally in sheet form). This approach to calorimetry is being investigated for SSC use by a collaboration of Ames Laboratory/Iowa State University, Argonne National Laboratory, Bicron Corporation, Florida State University, Louisiana State University, University of Mississippi, Oak Ridge National Laboratory, Virginia Polytechnic Institute and State University, Westinghouse Electric Corporation, and University of Wisconsin.

  1. Plate tectonics and planetary habitability: current status and future challenges.

    PubMed

    Korenaga, Jun

    2012-07-01

    Plate tectonics is one of the major factors affecting the potential habitability of a terrestrial planet. The physics of plate tectonics is, however, still far from being complete, leading to considerable uncertainty when discussing planetary habitability. Here, I summarize recent developments on the evolution of plate tectonics on Earth, which suggest a radically new view on Earth dynamics: convection in the mantle has been speeding up despite its secular cooling, and the operation of plate tectonics has been facilitated throughout Earth's history by the gradual subduction of water into an initially dry mantle. The role of plate tectonics in planetary habitability through its influence on atmospheric evolution is still difficult to quantify, and, to this end, it will be vital to better understand a coupled core-mantle-atmosphere system in the context of solar system evolution. PMID:22256796

  2. A circuit model for the explosive-driven plate generator

    NASA Astrophysics Data System (ADS)

    Caird, R. S.; Erickson, D. J.; Fowler, C. M.; Freeman, B. L.; Goforth, J. H.

    Explosive-driven generators are modelled as lumped parameter circuit elements in order to estimate performance in applications and to optimize the design of experiments. The plate generator is essentially a parallel or tilted plate transmission line in which the current-carrying flat plate conductors are driven by plane wave explosive systems. A simple model for the time-varying inductance of this system was developed. First, an analytic expression is used to predict the plate motion. Then, the inductance is expressed as a function of plate separation to give the computational model. Time-dependent flux losses are accounted for by an increasing waste inductance. Model predictions are compared with the available shot data.

  3. An Optimized High Throughput Clean-Up Method Using Mixed-Mode SPE Plate for the Analysis of Free Arachidonic Acid in Plasma by LC-MS/MS

    PubMed Central

    Wang, Wan; Qin, Suzi; Li, Linsen; Chen, Xiaohua; Wang, Qunjie; Wei, Junfu

    2015-01-01

    A high throughput sample preparation method was developed utilizing mixed-mode solid phase extraction (SPE) in 96-well plate format for the determination of free arachidonic acid in plasma by LC-MS/MS. Plasma was mixed with 3% aqueous ammonia and loaded into each well of 96-well plate. After washing with water and methanol sequentially, 3% of formic acid in acetonitrile was used to elute arachidonic acid. The collected fraction was injected onto a reversed phase column at 30°C with mobile phase of acetonitrile/water (70 : 30, v/v) and detected by LC-MS/MS coupled with electrospray ionization (ESI) in multiple reaction monitoring (MRM) mode. The calibration curve ranged from 10 to 2500 ng/mL with sufficient linearity (r2 = 0.9999). The recoveries were in the range of 99.38% to 103.21% with RSD less than 6%. The limit of detection is 3 ng/mL. PMID:25873969

  4. Saliva-based system for health and toxicology monitoring

    NASA Astrophysics Data System (ADS)

    Fenner, D. B.; Stevens, A. E.; Rosen, D. I.; Ferrante, A. A.; Davis, S. J.

    2009-05-01

    The practical utility of technologies for early detection of human exposure to a variety of toxic agents has been limited in many cases by the absence of instruments suitable for first responders and at field hospitals. Microarrays provide multiplexed assay of a large number of human biomarkers, including cytokines and chemokines, indicators of immune system health. Assay of saliva is less invasive and provides quick indication of exposure especially of the respiratory system. Our pilot clinical study has uncovered an early cytokine response in human saliva. As a model for respiratory exposure, a cohort of 16 adult volunteers was challenged with FluMistTM vaccinations, an FDA approved, attenuated live influenza virus. Blood and saliva cytokine levels were monitored immediately prior to and up to 7 days afterwards. Bead assay found little change in blood cytokine levels while several of those in saliva were frequently elevated above two standard deviations on trial days one and three. We have developed a prototype portable saliva monitoring system consisting of microarray cytokine capture plate, luminescent reporter, and whole plate imaging. Assay is with a commercial 96-well plate spotted with up to 16 distinct biomarkers per well and read by chemiluminescence. A battery-powered, 16-bit, cooled-CCD camera and laptop PC provide imaging and data reduction. Detection limits of common inflammatory cytokines were measured at about 1-5 pg/ml which is within the clinically significant range for saliva of exposed individuals, as verified for samples from the small clinical trial. An expanded study of cytokine response in saliva of therapeutic radiation oncology patients is being launched.

  5. Wave interaction with dual circular porous plates

    NASA Astrophysics Data System (ADS)

    Mondal, Arpita; Gayen, R.

    2015-12-01

    In this paper we investigated the reflection and the transmission of a system of two symmetric circular-arc-shaped thin porous plates submerged in deep water within the context of linear theory. The hypersingular integral equation technique has been used to analyze the problem mathematically. The integral equations are formulated by applying Green's integral theorem to the fundamental potential function and the scattered potential function into a suitable fluid region, and then using the boundary condition on the porous plate surface. These are solved approximately using an expansion-cum-collocation method using the behaviour of the potential functions at the tips of the plates. This method ultimately produces a very good numerical approximation for the reflection and the transmission coefficients and hydrodynamic force components. The numerical results are depicted graphically against the wave number for a variety of layouts of the arc. Some results are compared with known results for similar configurations of dual rigid plate systems available in the literature with good agreement.

  6. BEPLATE emdash simulation of electrochemical plating

    SciTech Connect

    Giles, G.E. ); Gray, L.J. ); Bullock, J.S. IV )

    1990-09-01

    BEPLATE is a FORTRAN code that uses the boundary element method to simulate the electrochemical plating of material on parts, primarily rotating axisymmetric parts. A boundary element technique is used to solve for the local current density and thus the plating rate on the part, which is used to calculate the growth in the plated layer over a user-specified time step. The surface is moved to reflect this growth, and the new surface is used to generate the local current density. This cycle is repeated until the final time specified by the analyst, producing the final plated thickness. BEPLATE includes models for the polarization effects at both the part (cathode) and anode and allows the use of symmetry planes and nonconducting shields. For electroplating simulations, the part shape is normally assumed to be axisymmetric with a centerline along the z-axis. More general part shapes can be analyzed by BEPLATE if the surface growth simulation is not needed. In either case, the shield, anode, and tank geometries are not restricted to specific shapes. This report includes the information required to run BEPLATE, specifically, a brief description of the BEPLATE system including hardware and software requirements, a description of the complete simulation process, discussion of rules for generating models, and additional reference material. This system of codes consists of model generators (PIGS or PATRAN), input processor (BEPIN), the simulation code (BEPLATE) and postprocessing codes (PATRAN or CONPLOT).

  7. 10. DETAIL OF BUILDER'S PLATE AT NORTH PORTAL. PLATE READS: ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. DETAIL OF BUILDER'S PLATE AT NORTH PORTAL. PLATE READS: 1889, BUILT BY THE BERLIN IRON BRIDGE CO. EAST BERLIN CONN. DOUGLAS & JARVIS PAT. APT. 16, 1878, AP'L 17, 1885. A.P. FORESMAN, WM. S. STARR, T.J. STREBEIGH, COMMISSIONERS. - Pine Creek Bridge, River Road spanning Pine Creek, Jersey Shore, Lycoming County, PA

  8. Are allogenic or xenogenic screws and plates a reasonable alternative to alloplastic material for osteosynthesis--a histomorphological analysis in a dynamic system.

    PubMed

    Jacobsen, C; Obwegeser, J A

    2010-12-01

    Despite invention of titanium and resorbable screws and plates, still, one of the main challenges in bone fixation is the search for an ideal osteosynthetic material. Biomechanical properties, biocompatibility, and also cost effectiveness and clinical practicability are factors for the selection of a particular material. A promising alternative seems to be screws and plates made of bone. Recently, xenogenic bone pins and screws have been invented for use in joint surgery. In this study, screws made of allogenic sheep and xenogenic human bone were analyzed in a vital and dynamic sheep-model and compared to conventional titanium screws over a standard period of bone healing of 56 days with a constant applied extrusion force. Biomechanical analysis and histomorphological evaluation were performed. After 56 days of insertion xenogenic screws made of human bone showed significantly larger distance of extrusion of on average 173.8 μm compared to allogenic screws made of sheep bone of on average 27.8 and 29.95 μm of the titanium control group. Severe resorption processes with connective tissue interposition were found in the histomorphological analysis of the xenogenic screws in contrast to new bone formation and centripetal vascularization of the allogenic bone screw, as well as in processes of incorporation of the titanium control group. The study showed allogenic cortical bone screws as a substantial alternative to titanium screws with good biomechanical properties. In contrast to other reports a different result was shown for the xenogenic bone screws. They showed insufficient holding strength with confirmative histomorphological signs of degradation and insufficient osseointegration. Before common clinical use of xenogenic osteosynthetic material, further evaluation should be performed. PMID:20813368

  9. From Neural Plate to Cortical Arousal—A Neuronal Network Theory of Sleep Derived from in Vitro “Model” Systems for Primordial Patterns of Spontaneous Bioelectric Activity in the Vertebrate Central Nervous System

    PubMed Central

    Corner, Michael A.

    2013-01-01

    In the early 1960s intrinsically generated widespread neuronal discharges were discovered to be the basis for the earliest motor behavior throughout the animal kingdom. The pattern generating system is in fact programmed into the developing nervous system, in a regionally specific manner, already at the early neural plate stage. Such rhythmically modulated phasic bursts were next discovered to be a general feature of developing neural networks and, largely on the basis of experimental interventions in cultured neural tissues, to contribute significantly to their morpho-physiological maturation. In particular, the level of spontaneous synchronized bursting is homeostatically regulated, and has the effect of constraining the development of excessive network excitability. After birth or hatching, this “slow-wave” activity pattern becomes sporadically suppressed in favor of sensory oriented “waking” behaviors better adapted to dealing with environmental contingencies. It nevertheless reappears periodically as “sleep” at several species-specific points in the diurnal/nocturnal cycle. Although this “default” behavior pattern evolves with development, its essential features are preserved throughout the life cycle, and are based upon a few simple mechanisms which can be both experimentally demonstrated and simulated by computer modeling. In contrast, a late onto- and phylogenetic aspect of sleep, viz., the intermittent “paradoxical” activation of the forebrain so as to mimic waking activity, is much less well understood as regards its contribution to brain development. Some recent findings dealing with this question by means of cholinergically induced “aroused” firing patterns in developing neocortical cell cultures, followed by quantitative electrophysiological assays of immediate and longterm sequelae, will be discussed in connection with their putative implications for sleep ontogeny. PMID:24961426

  10. Plate tectonics conserves angular momentum

    NASA Astrophysics Data System (ADS)

    Bowin, C.

    2010-03-01

    A new combined understanding of plate tectonics, Earth internal structure, and the role of impulse in deformation of the Earth's crust is presented. Plate accelerations and decelerations have been revealed by iterative filtering of the quaternion history for the Euler poles that define absolute plate motion history for the past 68 million years, and provide an unprecedented precision for plate angular rotation variations with time at 2-million year intervals. Stage poles represent the angular rotation of a plate's motion between adjacent Euler poles, and from which the maximum velocity vector for a plate can be determined. The consistent maximum velocity variations, in turn, yield consistent estimates of plate accelerations and decelerations. The fact that the Pacific plate was shown to accelerate and decelerate, implied that conservation of plate tectonic angular momentum must be globally conserved, and that is confirmed by the results shown here (total angular momentum ~1.4+27 kg m2 s-1). Accordingly, if a plate decelerates, other plates must increase their angular momentums to compensate. In addition, the azimuth of the maximum velocity vectors yields clues as to why the "bend" in the Emperor-Hawaiian seamount trend occurred near 46 Myr. This report summarizes processing results for 12 of the 14 major tectonic plates of the Earth (except for the Juan de Fuca and Philippine plates). Plate accelerations support the contention that plate tectonics is a product of torques that most likely are sustained by the sinking of positive density anomalies revealed by geoid anomalies of the degree 4-10 packet of the Earth's spherical harmonic coefficients. These linear positive geoid anomalies underlie plate subduction zones and are presumed due to phase changes in subducted gabbroic lithosphere at depth in the upper lower mantle (above 1200 km depth). The tectonic plates are pulled along by the sinking of these positive mass anomalies, rather than moving at near constant

  11. Regenerate metal-plating baths to cut waste and save

    SciTech Connect

    1995-03-01

    During electrode-based metal plating of equipment components, the formation of an electrical field causes metal deposits to be thicker at edges and seams, and thinner on flat surfaces. And, electrode-based methods consume large amounts of energy. Electroless-nickel (EN) -- or autocatalytic -- plating systems were pioneered in the 1940s to solve these problems. EN plating produces a more uniform coating, irrespective of the complexity of the part, and it consumes less electricity, since to electric current is required during plating. Plating in an EN system results from a chemical reaction between nickel in the bath and the substrate of the equipment component. The downside of electroless plating, however, is the limited life of the nickel bath, and the large volume of metal waste produced by bath disposal. Ionsep Corp. (Wilmington, Del.) has developed an electrodialytic system that continuously reforms the EN plating baths, to give them longer life. Its patented system has been successfully laboratory tested in a 1-ft{sup 2} cell, and the firm recently won a $250,000 grant from the US Dept. of Energy (Washington, D.C.) and Environmental Protection Agency (Washington, D.C.), to design and engineer a commercial-scale version of the system.

  12. Plate tectonics, damage and inheritance.

    PubMed

    Bercovici, David; Ricard, Yanick

    2014-04-24

    The initiation of plate tectonics on Earth is a critical event in our planet's history. The time lag between the first proto-subduction (about 4 billion years ago) and global tectonics (approximately 3 billion years ago) suggests that plates and plate boundaries became widespread over a period of 1 billion years. The reason for this time lag is unknown but fundamental to understanding the origin of plate tectonics. Here we suggest that when sufficient lithospheric damage (which promotes shear localization and long-lived weak zones) combines with transient mantle flow and migrating proto-subduction, it leads to the accumulation of weak plate boundaries and eventually to fully formed tectonic plates driven by subduction alone. We simulate this process using a grain evolution and damage mechanism with a composite rheology (which is compatible with field and laboratory observations of polycrystalline rocks), coupled to an idealized model of pressure-driven lithospheric flow in which a low-pressure zone is equivalent to the suction of convective downwellings. In the simplest case, for Earth-like conditions, a few successive rotations of the driving pressure field yield relic damaged weak zones that are inherited by the lithospheric flow to form a nearly perfect plate, with passive spreading and strike-slip margins that persist and localize further, even though flow is driven only by subduction. But for hotter surface conditions, such as those on Venus, accumulation and inheritance of damage is negligible; hence only subduction zones survive and plate tectonics does not spread, which corresponds to observations. After plates have developed, continued changes in driving forces, combined with inherited damage and weak zones, promote increased tectonic complexity, such as oblique subduction, strike-slip boundaries that are subparallel to plate motion, and spalling of minor plates. PMID:24717430

  13. Stepped conical zone plate antenna

    NASA Astrophysics Data System (ADS)

    Wiltse, James C.

    2001-07-01

    The Fresnel zone plate lens was invented and developed for optical frequencies. However, fabrication difficulties at the short optical wavelengths have prevented obtain good efficiencies. At longer microwave or millimeter-wavelengths fabrication is easier and phase correcting zone plate antennas have been used to obtain good efficiencies. This paper describes a new type of phase correcting zone plate having even better efficiency, namely a diffraction efficiency of 99 percent compared to a true lens, and an overall efficiency much better than a true lens. For the usual zone plate antenna employed at microwave or millimeter wavelengths, path length adjustment is accomplished by cutting different depths in a dielectric plate or by using two or more dielectrics having different dielectric constants. The new design uses a tilted cut in a dielectric plate, which more accurately matches the shape of a true lens and produces much lower phase error. The construction is still near and can be made for example, by a milling machine with a tilted bit. For a circular zone plate, the lens is a stepped conical or tapered shape. Because the phase steps are small, the far-field antenna pattern is excellent and sidelobe-levels are very low. Analysis of typical configurations will be given, showing that phase errors are small, lower than those for an eighth-wave corrected phase zone plate.

  14. ChooseMyPlate.gov

    MedlinePlus

    ... Day You don’t have to be an Olympic athlete to be active. Taking the stairs instead of the elevator, mowing the lawn, and gardening count too! TWITTER FEED 2 days ChooseMyPlate.gov @MyPlate Make family dinner more fun with a game or activity. Challenge kids to solve a riddle ...

  15. Aseptic Laboratory Techniques: Plating Methods

    PubMed Central

    Sanders, Erin R.

    2012-01-01

    Microorganisms are present on all inanimate surfaces creating ubiquitous sources of possible contamination in the laboratory. Experimental success relies on the ability of a scientist to sterilize work surfaces and equipment as well as prevent contact of sterile instruments and solutions with non-sterile surfaces. Here we present the steps for several plating methods routinely used in the laboratory to isolate, propagate, or enumerate microorganisms such as bacteria and phage. All five methods incorporate aseptic technique, or procedures that maintain the sterility of experimental materials. Procedures described include (1) streak-plating bacterial cultures to isolate single colonies, (2) pour-plating and (3) spread-plating to enumerate viable bacterial colonies, (4) soft agar overlays to isolate phage and enumerate plaques, and (5) replica-plating to transfer cells from one plate to another in an identical spatial pattern. These procedures can be performed at the laboratory bench, provided they involve non-pathogenic strains of microorganisms (Biosafety Level 1, BSL-1). If working with BSL-2 organisms, then these manipulations must take place in a biosafety cabinet. Consult the most current edition of the Biosafety in Microbiological and Biomedical Laboratories (BMBL) as well as Material Safety Data Sheets (MSDS) for Infectious Substances to determine the biohazard classification as well as the safety precautions and containment facilities required for the microorganism in question. Bacterial strains and phage stocks can be obtained from research investigators, companies, and collections maintained by particular organizations such as the American Type Culture Collection (ATCC). It is recommended that non-pathogenic strains be used when learning the various plating methods. By following the procedures described in this protocol, students should be able to: ● Perform plating procedures without contaminating media. ● Isolate single bacterial colonies by the

  16. High-sensitive and high-efficient biochemical analysis method using a bionic electronic eye in combination with a smartphone-based colorimetric reader system.

    PubMed

    Kaiqi Su; Quchao Zou; Ning Hu; Ping Wang

    2015-08-01

    Bionic electronic eye (Bionic e-Eye), a developed smartphone-based colorimetric reader system, consists of smartphone or pad (iPhone 4s or iPad 3) as detection instrument and portable accessory as illumination provider, integrating with a wide-angle lens, a piece of lowest-power electro luminescent and a custom-made dark hood. A 96-well microtiter plate (MTP) was positioned on the electro luminescent and Bionic e-Eye captures the detection images by the back camera of smartphone. Being similar to human visual system, the hue, saturation and value (HSV, also called hex cone model) color model was employed in image processing algorithm of Bionic e-Eye. Optimized system dimension was determined by the system steadiness experiment of different photograph distances. Moreover, the commercially available BCA protein assay and CCK8 cell number assay were carried out to evaluate this Bionic e-Eye. Analytical performance of Bionic e-Eye had the better precision, higher sensitivity than microtiter plate reader (MTPR) and previous smartphone-based colorimetric reader for both two assays. Also, Bionic e-Eye using optical image detection had simultaneous and synchronous working mode, while MPTR using machine moving detection had asynchronous working mode in high throughput detection. Therefore, Bionic e-Eye will be an ideal point-of-care (POC) colorimetric detection device in the field of clinical application, industrial quality control, environment monitoring, and food assessment. PMID:26738081

  17. Present-day plate motions

    NASA Technical Reports Server (NTRS)

    Minster, J. B.; Jordan, T. H.

    1977-01-01

    A data set comprising 110 spreading rates, 78 transform fault azimuths and 142 earthquake slip vectors was inverted to yield a new instantaneous plate motion model, designated RM2. The mean averaging interval for the relative motion data was reduced to less than 3 My. A detailed comparison of RM2 with angular velocity vectors which best fit the data along individual plate boundaries indicates that RM2 performs close to optimally in most regions, with several notable exceptions. On the other hand, a previous estimate (RM1) failed to satisfy an extensive set of new data collected in the South Atlantic Ocean. It is shown that RM1 incorrectly predicts the plate kinematics in the South Atlantic because the presently available data are inconsistent with the plate geometry assumed in deriving RM1. It is demonstrated that this inconsistency can be remedied by postulating the existence of internal deformation with the Indian plate, although alternate explanations are possible.

  18. Impact damage of composite plates

    NASA Technical Reports Server (NTRS)

    Lal, K. M.; Goglia, G. L.

    1983-01-01

    A simple model to study low velocity transverse impact of thin plates made of fiber-reinforced composite material, in particular T300/5208 graphite-epoxy was discussed. This model predicts the coefficient of restitution, which is a measure of the energy absorbed by the target during an impact event. The model is constructed on the assumption that the plate is inextensible in the fiber direction and that the material is incompressible in the z-direction. Such a plate essentially deforms by shear, hence this model neglects bending deformations of the plate. The coefficient of restitution is predicted to increase with large interlaminar shear strength and low transverse shear modulus of the laminate. Predictions are compared with the test results of impacted circular and rectangular clamped plates. Experimentally measured values of the coefficient of restitution are found to agree with the predicted values within a reasonable error.

  19. Statistical tests of additional plate boundaries from plate motion inversions

    NASA Technical Reports Server (NTRS)

    Stein, S.; Gordon, R. G.

    1984-01-01

    The application of the F-ratio test, a standard statistical technique, to the results of relative plate motion inversions has been investigated. The method tests whether the improvement in fit of the model to the data resulting from the addition of another plate to the model is greater than that expected purely by chance. This approach appears to be useful in determining whether additional plate boundaries are justified. Previous results have been confirmed favoring separate North American and South American plates with a boundary located beween 30 N and the equator. Using Chase's global relative motion data, it is shown that in addition to separate West African and Somalian plates, separate West Indian and Australian plates, with a best-fitting boundary between 70 E and 90 E, can be resolved. These results are generally consistent with the observation that the Indian plate's internal deformation extends somewhat westward of the Ninetyeast Ridge. The relative motion pole is similar to Minster and Jordan's and predicts the NW-SE compression observed in earthquake mechanisms near the Ninetyeast Ridge.

  20. Sub-Plate Overlap Code Documentation

    NASA Technical Reports Server (NTRS)

    Taff, L. G.; Bucciarelli, B.; Zarate, N.

    1997-01-01

    An expansion of the plate overlap method of astrometric data reduction to a single plate has been proposed and successfully tested. Each plate is (artificially) divided into sub-plates which can then be overlapped. This reduces the area of a 'plate' over which a plate model needs to accurately represent the relationship between measured coordinates and standard coordinates. Application is made to non-astrographic plates such as Schmidt plates and to wide-field astrographic plates. Indeed, the method is completely general and can be applied to any type of recording media.

  1. Elastocapillary coalescence of plates and pillars

    PubMed Central

    Wei, Z.; Schneider, T. M.; Kim, J.; Kim, H.-Y.; Aizenberg, J.; Mahadevan, L.

    2015-01-01

    When a fluid-immersed array of supported plates or pillars is dried, evaporation leads to the formation of menisci on the tips of the plates or pillars that bring them together to form complex patterns. Building on prior experimental observations, we use a combination of theory and computation to understand the nature of this instability and its evolution in both the two- and three-dimensional setting of the problem. For the case of plates, we explicitly derive the interaction torques based on the relevant physical parameters associated with pillar deformation, contact-line pinning/depinning and fluid volume changes. A Bloch-wave analysis for our periodic mechanical system captures the window of volumes where the two-plate eigenvalue characterizes the onset of the coalescence instability. We then study the evolution of these binary clusters and their eventual elastic arrest using numerical simulations that account for evaporative dynamics coupled to capillary coalescence. This explains both the formation of hierarchical clusters and the sensitive dependence of the final structures on initial perturbations, as seen in our experiments. We then generalize our analysis to treat the problem of pillar collapse in three dimensions, where the fluid domain is completely connected and the interface is a minimal surface with the uniform mean curvature. Our theory and simulations capture the salient features of experimental observations in a range of different situations and may thus be useful in controlling the ensuing patterns. PMID:25792949

  2. A swirl flow evaporative cold plate

    NASA Technical Reports Server (NTRS)

    Niggemann, R. E.; Greenlee, W. J.; Hill, D. G.; Ellis, W.; Marshall, P.

    1985-01-01

    A forced flow evaporative cold plate is under development for future application to the thermal bus concept being pursued by NASA for Space Station Thermal Control. The vaporizer is a swirl-flow device employing a spiral tube coil geometry sandwiched between conductive metal plates upon which electric components could be mounted. This concept is based on the inherent phase separation that occurs in a two phase stream in curvilinear flow. This is a zero 'g' design with one 'g' all-attitude capability and is capable of high heat transfer coefficients, good isothermality, and the ability to function at heat fluxes approaching 5w/sq cm on the cold plates (10w/sq cm on the tube wall) with Freon 114. The advantages of this design over other two phase evaporator approaches are high heat flux capability, simplified control requirements, insensitivity to micro-gravity oscillations, and inexpensive manufacturability. The program included design, fabrication, and test of such a cold plate utilizing an existing test stand developed for two-phase thermal management system (TPTMS) testing. Test results analysis and conclusions are included.

  3. Digitization of Archives of Astronomical Plates

    NASA Astrophysics Data System (ADS)

    Omizzolo, Alessandro; Cesare, Barbieri; Blanco, Carlo; Bucciarelli, Beatrice; di Paola, Andrea; Nesci, Roberto

    The photographic plate archives of telescopes around the world contain a veritable treasury of astronomical data. Unfortunately the emulsion is a volatile support and full exploitation of the scientific content is more and more difficult. A large-scale two-year project to digitize the archive of plates of the Italian Astronomical Observatories and of the Specola Vaticana has been started in 2002 with funds from the Ministry of the University and Research following a pilot program funded by the University of Padova in 2001. Identical systems composed by a high quality commercial scanner plus dedicated personal computers and acquisition software (developed initially at DLR Berlin) have been installed in all participating Institutes. Three main goals make up the total project: to provide high quality photometric sequences with the Campo Imperatore telescopes to be used on the scanned plates to perform astrometric measures taking advantage of the large span of time covered by the plates and to distribute the digitized information to all interested researchers via the international Web. This paper presents some of the activities carried out and results obtained so far

  4. Fabrication procedures for HFIR control plates

    SciTech Connect

    Bowden, G.A.; Hicks, G.R.; Knight, R.W.

    1984-10-01

    The HFIR control system uses Alclad cylindrically shaped components, which have regions containing 31 vol % Eu/sub 2/O/sub 3/ and 38 vol % Ta, respectively. Exacting control of the water passage between these components and adjacent reactor parts is mandatory, and precise dimensional control of the finished products is required. This report describes the procedures developed for manufacturing outer control plates and inner control cylinders. Results are cited which demonstrate that circular-shaped outer control plates can be produced with less than 0.025-in. variation from the specified 9.300-in. radius in any region of the plate. Other results show that, by the exercise of careful control, inner control, inner control plates can be welded into cylindrical geometry with diametrical variations held to less than +- 0.010 in. of the intended 17.846-in. average diam. The cylinders can then be explosively sized, while under compression, with diametric variations of less than 0.005 in. while controlling roundness variations to less than 0.030 in. from the specified 17.842-in. finished diam.

  5. Experimental investigation on fracture of layered plates

    NASA Astrophysics Data System (ADS)

    Agnihotri, Servesh; Parameswaran, Venkitanarayanan

    2015-03-01

    Layered structures, used in many applications such as windshields, thermal protection systems, heavy armor etc., are comprised of layers having different elastic and fracture properties. Present study focuses on understanding the behavior of cracks in a layered plate oriented in such a way that there are property jumps across the crack front. Two layer plates were fabricated by joining Polymethylmethacrylate (PMMA) and epoxy sheets using an epoxy based adhesive (Araldite). Single edge notched specimens were subjected to mixed mode loading using the asymmetric four point bending configuration. The results of the study indicated that the failure in two layer plates is progressive in nature. Crack extension starts in the most vulnerable layer (epoxy) first and the crack grows in a sequence of jumps and arrests in this layer. Once this crack reaches a particular length the crack in the second layer starts extending resulting in final failure of the plate. Similar sequence of events was observed in the case of dynamically loaded samples. The predictions of the load at which epoxy crack starts growing and the angle at which the crack grows using the maximum tensile stress criteria were in reasonable agreement with the experimentally observed values.

  6. Highly curved microchannel plates

    NASA Technical Reports Server (NTRS)

    Siegmund, O. H. W.; Cully, S.; Warren, J.; Gaines, G. A.; Priedhorsky, W.; Bloch, J.

    1990-01-01

    Several spherically curved microchannel plate (MCP) stack configurations were studied as part of an ongoing astrophysical detector development program, and as part of the development of the ALEXIS satellite payload. MCP pairs with surface radii of curvature as small as 7 cm, and diameters up to 46 mm have been evaluated. The experiments show that the gain (greater than 1.5 x 10 exp 7) and background characteristics (about 0.5 events/sq cm per sec) of highly curved MCP stacks are in general equivalent to the performance achieved with flat MCP stacks of similar configuration. However, gain variations across the curved MCP's due to variations in the channel length to diameter ratio are observed. The overall pulse height distribution of a highly curved surface MCP stack (greater than 50 percent FWHM) is thus broader than its flat counterpart (less than 30 percent). Preconditioning of curved MCP stacks gives comparable results to flat MCP stacks, but it also decreases the overall gain variations. Flat fields of curved MCP stacks have the same general characteristics as flat MCP stacks.

  7. Balanced Orifice Plate

    NASA Technical Reports Server (NTRS)

    Kelley, Anthony R. (Inventor); Buskirk, Paul D. (Inventor)

    2006-01-01

    An orifice plate for use in a conduit through which fluid flows is defined by a central circular region having a radius R, and a ring-shaped region surrounding the central circular region. The ring-shaped region has holes formed therethrough with those holes centered at each radius R thereof satisfying a relationship A(sub R)=al(X(sub R)V(sub R)(sup b)) where A(sub R) is a sum of areas of those holes having centers at radius R, X(sub R) is a flow coefficient at radius R, V(sub R) is a velocity of the fluid that is to flow through the conduit at radius R, b is a constant selected to make at least one process variable (associated with the fluid that is to flow through the conduit) approximately equal at each radius R, and a is a constant that is equal to (X(sub R)A(sub R)V(sub R)(sup b)) at each radius R.

  8. Application research of CO2 laser cutting natural stone plates

    NASA Astrophysics Data System (ADS)

    Ma, Lixiu; Song, Jijiang

    2009-08-01

    Now, the processing of natural stone plates is the high performance sawing machine primarily,many researchers deeply studied the processing characters in the sawing process and the strength characters during the processing. In order to realize the profiled-processing and pattern- carving of the natural stone, It lays a solid foundation for the laser cutting and the pattern-carving technology of natural stone plate. The working principle, type and characteristics of laser cutting are briefly described. The paper selects 6 kinds stone plates of natural taken as experimental sample,the experimental sample was China Shanxi Black, Old Spain Golden Yellow, New Spain Golden Yellow, Jazz White, Maple Leaf Red, Cream White respectively. Use high power CO2 laser cutting system,the stone plates cutting experiment of 6 kinds different hardness, the best working speed are obtained,The experimental results indicate that: The laser cutting speed has no correlation with the ingredient content of stone plate.

  9. What drives micro-plate motion and deformation in the northeastern Caribbean plate boundary region?

    NASA Astrophysics Data System (ADS)

    Govers, R. M. A.; Wortel, M. J. R.; van Benthem, S.

    2015-12-01

    The north Caribbean plate boundary zone is a broad deformation zone with several fault systems and tectonic blocks that move with different velocities. The indentation by the Bahamas Platform (the "Bahamas Collision") is generally invoked as a cause of this fragmentation. We propose that a second driver of deformation is the western edge of the south-dipping Puerto Rico slab moving sideways with the North America plate. This proposal derives from our recently imaged tomographic structure of the Lesser Antilles - Puerto Rico slab. The westward motion of the slab edge results in a push on the Caribbean plate further west. We refer to this second mechanism for deformation as "Slab Edge Push". The motion of the North America plate relative to the Caribbean plate causes both drivers to migrate from east to west. The Bahamas Collision and Slab Edge Push have been operating simultaneously since the Miocene. The question is the relative importance of the two mechanisms. We use mechanical finite element models that represent the two mechanisms from the Late Oligocene (30 Ma) to the Present. For the Present, both models successfully reproduce observed deformation, implying that both models are viable. Back in time the Slab Edge Push mechanism better reproduces observations. Neither mechanism successfully reproduces the observed Miocene counter-clockwise rotation of Puerto Rico. We use this rotation to tune a final model that includes fractional contributions of both mechanisms. Both mechanisms contribute equally to the motion of the Caribbean plate. We find that the Slab Edge Push was the dominant driver of deformation in the north Caribbean plate boundary zone since 30 Ma.

  10. Mantle convection with plates and mobile, faulted plate margins.

    PubMed

    Zhong, S; Gurnis, M

    1995-02-10

    A finite-element formulation of faults has been incorporated into time-dependent models of mantle convection with realistic rheology, continents, and phase changes. Realistic tectonic plates naturally form with self-consistent coupling between plate and mantle dynamics. After the initiation of subduction, trenches rapidly roll back with subducted slabs temporarily laid out along the base of the transition zone. After the slabs have penetrated into the lower mantle, the velocity of trench migration decreases markedly. The inhibition of slab penetration into the lower mantle by the 670-kilometer phase change is greatly reduced in these models as compared to models without tectonic plates. PMID:17813909

  11. 3He Bilayer Film Adsorbed on Graphite Plated with a Bilayer of 4He: a New Frustrated 2D Magnetic System

    NASA Astrophysics Data System (ADS)

    Neumann, Michael; Nyéki, Ján; Cowan, Brian; Saunders, John

    2006-09-01

    The heat capacity and NMR response of a 3He bilayer adsorbed on graphite plated with a bilayer of 4He have been measured over the temperature range 1-80 mK. We find that the first 3He layer requires the presence of a 3He fluid overlayer before it solidifies. Solidification is completed at a total coverage close to 9.85 nm-2, On further increasing the coverage the heat capacity maximum grows from `antiferromagnetic-like' (AFM-like) to `ferromagnetic-like' (FM-like). On the other hand, when the 3He layer first solidifies, it has a low temperature saturation magnetisation corresponding to a significant fraction of full polarisation, and this increases with increasing coverage. Furthermore the effective exchange constant inferred from the high temperature magnetisation data is always ferromagnetic. The effective exchange constants inferred from the heat capacity and magnetisation are significantly larger than those observed in the second layer of pure 3He films adsorbed on bare graphite. Otherwise there are strong similarities in the coverage dependence of the heat capacity and magnetisation, providing fresh insights into how the magnetic ground state of such 2D magnets evolves as the frustration is tuned with increasing coverage.

  12. 49 CFR 229.85 - Doors and cover plates marked “Danger”.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Doors and cover plates marked âDangerâ. 229.85 Section 229.85 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD... System § 229.85 Doors and cover plates marked “Danger”. All doors and cover plates guarding high...

  13. 49 CFR 229.85 - Doors and cover plates marked “Danger”.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Doors and cover plates marked âDangerâ. 229.85 Section 229.85 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD... System § 229.85 Doors and cover plates marked “Danger”. All doors and cover plates guarding high...

  14. Vacuum fusion bonded glass plates having microstructures thereon

    DOEpatents

    Swierkowski, Steve P.; Davidson, James C.; Balch, Joseph W.

    2001-01-01

    An improved apparatus and method for vacuum fusion bonding of large, patterned glass plates. One or both glass plates are patterned with etched features such as microstructure capillaries and a vacuum pumpout moat, with one plate having at least one hole therethrough for communication with a vacuum pumpout fixture. High accuracy alignment of the plates is accomplished by a temporary clamping fixture until the start of the fusion bonding heat cycle. A complete, void-free fusion bond of seamless, full-strength quality is obtained through the plates; because the glass is heated well into its softening point and because of a large, distributed force that is developed that presses the two plates together from the difference in pressure between the furnace ambient (high pressure) and the channeling and microstructures in the plates (low pressure) due to the vacuum drawn. The apparatus and method may be used to fabricate microcapillary arrays for chemical electrophoresis; for example, any apparatus using a network of microfluidic channels embedded between plates of glass or similar moderate melting point substrates with a gradual softening point curve, or for assembly of glass-based substrates onto larger substrates, such as in flat panel display systems.

  15. Ultrasonic Testing of NIF Amplifier FAU Top Plates

    SciTech Connect

    Chinn, D J; Huber, R D; Haskins, J J; Rodriguez, J A; Souza, P R; Le, T V

    2002-05-07

    A key component in the National Ignition Facility (NIF) laser optic system is the amplifier frame assembly unit (FAU). The cast aluminum top plate that supports the FAU is required to withstand loads that would occur during an earthquake with a recurrence period of 1000 years. The stringent seismic requirements placed on the FAU top plate induced a study of the cast aluminum material used in the top plate. Ultrasonic testing was used to aid in characterizing the aluminum material used in the plates. This report documents the work performed using contact ultrasonic testing to characterize the FAU top plate material. The ultrasonic work reported here had 3 objectives: (1) inspect the plate material before cyclic testing conducted at the Pacific Earthquake Engineering Research Center (PEER); (2) determine the overall quality of individual plates; and (3) detect large defects in critical areas of individual plates. Section III, ''Pre-cyclic test inspection'', describes work performed in support of Objective 1. Section IV, ''Ultrasonic field measurements'', describes work performed in support of Objectives 2 and 3.

  16. Droplet formation under the effect of a flexible nozzle plate.

    PubMed

    Sangplung, S; Liburdy, J A

    2009-09-01

    Droplet formation from a flexible nozzle plate driven by a prescribed-waveform excitation of a piezoelectric is numerically investigated using a computational fluid dynamics (CFD) model with the volume of fluid (VOF) method. The droplet generator with a flexible nozzle plate, which is free to vibrate due to the pressure acting on the plate, is modeled in a CFD computational domain. The CFD analysis includes the fluid-structure interaction between fluid and a flexible plate using large deflection theory. The problem is characterized by the nondimensional variables based on the capillary parameters of time, velocity, and pressure. The CFD model is validated with the experiment results. This study examines the characteristics of the applied waveforms and nozzle plate material properties to change the vibrational characteristics of the nozzle plate. The effect of fluid properties on the droplet formation process is also investigated focusing on surface tension and viscous forces. Increasing the impulse of the piezoelectric can be used to cause a higher droplet velocity and it is shown that the vibration of the nozzle plate has a strong effect on the droplet velocity, shape, and volume. Surface tension has a strong influence on the droplet formation characteristics in contrast to viscous forces. For the combination of a fluid with high surface tension and the most flexible nozzle plate, this system cannot cause the droplet ejected out of the nozzle. PMID:19501837

  17. Nonlinear dynamics of axially moving plates

    NASA Astrophysics Data System (ADS)

    Ghayesh, Mergen H.; Amabili, Marco; Païdoussis, Michael P.

    2013-01-01

    The nonlinear dynamics for forced motions of an axially moving plate is numerically investigated using Von Kármán plate theory and retaining in-plane displacements and inertia. The equations of motion are obtained via an energy method based on Lagrange equations. This yields a set of second-order nonlinear ordinary differential equations with coupled terms. The equations are transformed into a set of first-order nonlinear ordinary differential equations and are solved via the pseudo-arclength continuation technique. The near-resonance nonlinear dynamics is examined via plotting the frequency-response curves of the system. Results are shown through frequency-response curves, time histories, and phase-plane diagrams. The effect of system parameters, such as the axial speed and the pretension, on the resonant responses is also highlighted.

  18. Vibration characteristics of rectangular plate in compressible inviscid fluid

    NASA Astrophysics Data System (ADS)

    Liao, Chan-Yi; Ma, Chien-Ching

    2016-02-01

    This paper presents a mathematical derivation of the vibration characteristics of an elastic thin plate placed at the bottom of a three dimensional rectangular container filled with compressible inviscid fluid. A set of beam functions is used as the admissible functions of the plate in a fluid-plate system, and the motion of the fluid induced by the deformation of the plate is obtained from a three-dimensional acoustic equation. Pressure from the fluid over the fluid-plate interface is integrated to form a virtual mass matrix. The frequency equation of the fluid-plate system is derived by combining mass, stiffness, and the virtual mass matrix. Solving the frequency equation makes it possible to obtain the dynamic characteristic of the fluid-plate system, such as resonant frequencies, corresponding mode shapes, and velocity of the fluid. Numerical calculations were performed for plates coupled with fluids with various degrees of compressibility to illustrate the difference between compressible and incompressible fluids in a fluid-plate system. The proposed method could be used to predict resonant frequencies and mode shapes with accuracy compared to that of incompressible fluid theory (IFT). The proposed method can be used to analyze cases involving high value of sound velocity, such as incompressible fluids. When the sound velocity approaches infinity, the results obtained for compressible fluids are similar to those of incompressible fluids. We also examined the influence of fluid compressibility on vibration characteristics in which a decrease in sound velocity was shown to correspond to a decrease in resonant frequency. Additional modes, not observed in incompressible fluids, were obtained in cases of low sound velocity, particularly at higher resonant frequencies. Fluid velocity plots clearly reveal that the additional resonant modes can be attributed to the compressible behavior of the fluid.

  19. Difficulties encountered removing locked plates

    PubMed Central

    Raja, S; Imbuldeniya, AM; S, Garg; Groom, G

    2012-01-01

    INTRODUCTION Locked plates are commonly used to obtain fixation in periarticular and comminuted fractures. Their use has also gained popularity in repairing fractures in osteoporotic bone. These plates provide stable fixation and promote biological healing. Over the last 3 years, we have used over 150 locked plates with varying success to fix periarticular fractures involving mainly the knee and ankle. In this study, we report our clinical experience and the difficulties encountered when removing locked plates in adult patients with a variety of indications including implant failure, infection, non-union and a palpable symptomatic implant. METHODS A retrospective analysis was performed of patients enrolled prospectively into a database. Included in the study were 36 consecutive adult patients who each underwent the procedure of locked plate removal in a single inner city level 1 trauma centre. Data collected included primary indication for fixation, indication for implant removal, time of the implant in situ, grade of operating surgeon and difficulties encountered during the procedure. RESULTS Implant removal was associated with a complication rate of 47%. The major problems encountered were difficulty in removing the locked screws and the implant itself. A total of ten cold welded screws were found in eight cases. Removal was facilitated by high speed metal cutting burrs and screw removal sets in all but one case, where a decision was made to leave the plate in situ. CONCLUSIONS The majority of studies investigating implant removal and problems encountered in doing so report a relatively high complication rate. With the advent of locking plates and their growing popularity, difficulties are now being seen intra-operatively when removing them. There is a paucity of data, however, specifically directed at locking plate removal. We recommend that surgeons should be aware of the potential complications while removing locked plates. Fluoroscopic control and all

  20. High-throughput micro plate assays for screening flavonoid content and DPPH-scavenging activity in sorghum bran and flour

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Rapid, 96-well microtiter assays were compared to conventional assays for quantifying total phenolic content, flavonoid content, and 2,2-diphenyl-1-picrylhydrazyl (DPPH) in sorghum grain. The 96-well assays exhibited a correlation of >0.9 to the conventional assays. The 96-well assays allowed for ...