Science.gov

Sample records for aa2024-t35 joints aa2024-t35

  1. Joint swelling

    MedlinePlus

    Swelling of a joint ... Joint swelling may occur along with joint pain . The swelling may cause the joint to appear larger or abnormally shaped. Joint swelling can cause pain or stiffness. After an ...

  2. Joint Disorders

    MedlinePlus

    A joint is where two or more bones come together, like the knee, hip, elbow, or shoulder. Joints can be damaged by many types of injuries or diseases, including Arthritis - inflammation of a joint. It causes pain, stiffness, and swelling. Over time, ...

  3. Ceramic joints

    DOEpatents

    Miller, Bradley J.; Patten, Jr., Donald O.

    1991-01-01

    Butt joints between materials having different coefficients of thermal expansion are prepared having a reduced probability of failure of stress facture. This is accomplished by narrowing/tapering the material having the lower coefficient of thermal expansion in a direction away from the joint interface and not joining the narrow-tapered surface to the material having the higher coefficient of thermal expansion.

  4. Temporomandibular Joint, Closed

    MedlinePlus

    ... Oral Health > The Temporomandibular Joint, Closed The Temporomandibular Joint, Closed Main Content Title: The Temporomandibular Joint, Closed Description: The temporomandibular joint connects the lower ...

  5. Compliant joint

    NASA Technical Reports Server (NTRS)

    Eklund, Wayne D. (Inventor); Kerley, James J. (Inventor)

    1990-01-01

    A compliant joint is provided for prosthetic and robotic devices which permits rotation in three different planes. The joint provides for the controlled use of cable under motion. Perpendicular outer mounting frames are joined by swaged cables that interlock at a center block. Ball bearings allow for the free rotation of the second mounting frame relative to the first mounting frame within a predetermined angular rotation that is controlled by two stop devices. The cables allow for compliance at the stops and the cables allow for compliance in six degrees of freedom enabling the duplication or simulation of the rotational movement and flexibility of a natural hip or knee joint, as well as the simulation of a joint designed for a specific robotic component for predetermined design parameters.

  6. Joint Commission

    MedlinePlus

    ... Sunday 1:00 CST, November 6, 2016 Workplace Violence Prevention Resources The Joint Commission has launched “Workplace Violence Prevention Resources,” an online resource center dedicated to ...

  7. Joint Problems

    MedlinePlus

    ... ankles and toes. Other types of arthritis include gout or pseudogout. Sometimes, there is a mechanical problem ... for more information on osteoarthritis, rheumatoid arthritis and gout. How Common are Joint Problems? Osteoarthritis, which affects ...

  8. Joint assembly

    NASA Technical Reports Server (NTRS)

    Wilson, Andrew (Inventor); Punnoose, Andrew (Inventor); Strausser, Katherine (Inventor); Parikh, Neil (Inventor)

    2010-01-01

    A joint assembly is provided which includes a drive assembly and a swivel mechanism. The drive assembly features a motor operatively associated with a plurality of drive shafts for driving auxiliary elements, and a plurality of swivel shafts for pivoting the drive assembly. The swivel mechanism engages the swivel shafts and has a fixable element that may be attached to a foundation. The swivel mechanism is adapted to cooperate with the swivel shafts to pivot the drive assembly with at least two degrees of freedom relative to the foundation. The joint assembly allows for all components to remain encased in a tight, compact, and sealed package, making it ideal for space, exploratory, and commercial applications.

  9. Joint x-ray

    MedlinePlus

    X-ray - joint; Arthrography; Arthrogram ... x-ray technologist will help you position the joint to be x-rayed on the table. Once in place, pictures are taken. The joint may be moved into other positions for more ...

  10. Joint Instability and Osteoarthritis

    PubMed Central

    Blalock, Darryl; Miller, Andrew; Tilley, Michael; Wang, Jinxi

    2015-01-01

    Joint instability creates a clinical and economic burden in the health care system. Injuries and disorders that directly damage the joint structure or lead to joint instability are highly associated with osteoarthritis (OA). Thus, understanding the physiology of joint stability and the mechanisms of joint instability-induced OA is of clinical significance. The first section of this review discusses the structure and function of major joint tissues, including periarticular muscles, which play a significant role in joint stability. Because the knee, ankle, and shoulder joints demonstrate a high incidence of ligament injury and joint instability, the second section summarizes the mechanisms of ligament injury-associated joint instability of these joints. The final section highlights the recent advances in the understanding of the mechanical and biological mechanisms of joint instability-induced OA. These advances may lead to new opportunities for clinical intervention in the prevention and early treatment of OA. PMID:25741184

  11. Spacesuit mobility knee joints

    NASA Technical Reports Server (NTRS)

    Vykukal, H. C. (Inventor)

    1979-01-01

    Pressure suit mobility joints are for use in interconnecting adjacent segments of an hermetically sealed spacesuit in which low torques, low leakage and a high degree of reliability are required. Each of the joints is a special purpose joint characterized by substantially constant volume and low torque characteristics and includes linkages which restrain the joint from longitudinal distension and includes a flexible, substantially impermeable diaphragm of tubular configuration spanning the distance between pivotally supported annuli. The diaphragms of selected joints include rolling convolutions for balancing the joints, while various joints include wedge-shaped sections which enhance the range of motion for the joints.

  12. Spacesuit mobility joints

    NASA Technical Reports Server (NTRS)

    Vykukal, H. C. (Inventor)

    1978-01-01

    Joints for use in interconnecting adjacent segments of an hermetically sealed spacesuit which have low torques, low leakage and a high degree of reliability are described. Each of the joints is a special purpose joint characterized by substantially constant volume and low torque characteristics. Linkages which restrain the joint from longitudinal distension and a flexible, substantially impermeable diaphragm of tubular configuration spanning the distance between pivotally supported annuli are featured. The diaphragms of selected joints include rolling convolutions for balancing the joints, while various joints include wedge-shaped sections which enhance the range of motion for the joints.

  13. Butt Joint Tool Commissioning

    SciTech Connect

    Martovetsky, N N

    2007-12-06

    ITER Central Solenoid uses butt joints for connecting the pancakes in the CS module. The principles of the butt joining of the CICC were developed by the JAPT during CSMC project. The difference between the CSMC butt joint and the CS butt joint is that the CS butt joint is an in-line joint, while the CSMC is a double joint through a hairpin jumper. The CS butt joint has to carry the hoop load. The straight length of the joint is only 320 mm, and the vacuum chamber around the joint has to have a split in the clamp shell. These requirements are challenging. Fig.1 presents a CSMC joint, and Fig.2 shows a CS butt joint. The butt joint procedure was verified and demonstrated. The tool is capable of achieving all specified parameters. The vacuum in the end was a little higher than the target, which is not critical and readily correctable. We consider, tentatively that the procedure is established. Unexpectedly, we discover significant temperature nonuniformity in the joint cross section, which is not formally a violation of the specs, but is a point of concern. All testing parameters are recorded for QA purposes. We plan to modify the butt joining tool to improve its convenience of operation and provide all features necessary for production of butt joints by qualified personnel.

  14. Pressure suit joint analyzer

    NASA Technical Reports Server (NTRS)

    Vykukal, H. C.; Webbon, B. W. (Inventor)

    1982-01-01

    A measurement system for simultaneously measuring torque and angular flexure in a pressure suit joint is described. One end of a joint under test is held rigid. A torque transducer is pivotably supported on the other movable end of a joint. A potentiometer is attached to the transducer by an arm. The wiper shaft of the potentiometer is gripped by a reference arm that rotates the wiper shaft the same angle as the flexure of joint. A signal is generated by the potentiometer which is representative of the joint flexure. A compensation circuit converts the output of the transducer to a signal representative of joint torque.

  15. Culture - joint fluid

    MedlinePlus

    Joint fluid culture ... fungi, or viruses grow. This is called a culture. If these germs are detected, other tests may ... is no special preparation needed for the lab culture. How to prepare for the removal of joint ...

  16. Temporomandibular Joint Dysfunction

    MedlinePlus

    The temporomandibular joint (TMJ) connects your jaw to the side of your head. When it works well, it enables you to ... For people with TMJ dysfunction, problems with the joint and muscles around it may cause Pain that ...

  17. Large displacement spherical joint

    DOEpatents

    Bieg, Lothar F.; Benavides, Gilbert L.

    2002-01-01

    A new class of spherical joints has a very large accessible full cone angle, a property which is beneficial for a wide range of applications. Despite the large cone angles, these joints move freely without singularities.

  18. Hip joint replacement

    MedlinePlus

    ... this page: //medlineplus.gov/ency/article/002975.htm Hip joint replacement To use the sharing features on this page, please enable JavaScript. Hip joint replacement is surgery to replace all or part ...

  19. [Total temporomandibular joint prostheses].

    PubMed

    Zwetyenga, N; Amroun, S; Wajszczak, B-L; Moris, V

    2016-09-01

    The temporomandibular joint (TMJ) is probably the most complex human joint. As in all joints, its prosthetic replacement may be indicated in selected cases. Significant advances have been made in the design of TMJ prostheses during the last three decades and the indications have been clarified. The aim of our work was to make an update on the current total TMJ total joint replacement. Indications, contraindications, prosthetic components, advantages, disadvantages, reasons for failure or reoperation, virtual planning and surgical protocol have been exposed.

  20. Joint Enrollment Report, 2014

    ERIC Educational Resources Information Center

    Iowa Department of Education, 2014

    2014-01-01

    The Iowa Department of Education collects information on joint enrollment in Iowa's 15 community colleges. Jointly enrolled students are high school students enrolled in community college credit coursework. Most jointly enrolled students enroll through Senior Year Plus (SYP) programs such as Postsecondary Enrollment Options (PSEO) and concurrent…

  1. Arch & Chord Joint Detail; Crossbracing Center Joint Detail; Chord, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Arch & Chord Joint Detail; Crossbracing Center Joint Detail; Chord, Panel Post, Tie & Diagonal Brace Joint Detail; Chord, Panel Post, Tie & Crossbracing Joint Detail - Dunlapsville Covered Bridge, Spanning East Fork Whitewater River, Dunlapsville, Union County, IN

  2. Joint custody: preliminary impressions.

    PubMed

    Awad, G A

    1983-02-01

    Joint custody is currently a popular and debatable issue. It is felt that some of the controversy is due to the lack of agreement on a definition. Following some examples of the differences in personal and judicial definitions of joint custody, a classification of custody is offered. Four types of custody arrangements are described: Absolute Sole Custody, Sole Custody, Non-Alternating Joint Custody (disputed and undisputed) and Alternating Joint Custody (disputed and undisputed). A critical review of the literature follows. Finally, clinical impressions about the two types of joint custody are discussed. PMID:6839267

  3. Temporomandibular joint osteoarthrosis and temporomandibular joint hypermobility.

    PubMed

    Dijkstra, P U; de Bont, L G; de Leeuw, R; Stegenga, B; Boering, G

    1993-10-01

    For studying the relationship between condylar hypermobility of the temporomandibular joint (TMJ) and osteoarthrosis (OA), 13 patients with bilateral condylar hypermobility were evaluated clinically and radiographically, 30 years after non-surgical treatment. The evaluation included range of motion, joint and muscle tenderness to palpation, joint sounds and masticatory function. Radiographs of the TMJs were evaluated for the absence or presence of degenerative changes. The hypermobile group (HG) was compared with a control group (CG) (n = 13). The CG was evaluated in the same way as the HG. Statistics included t-tests (to compare ranges of motion in the HG over time and to compare ranges of motion in HG and CG), non-parametric tests (to compare tenderness of muscles and joints, joint sounds, masticatory function and radiographic changes over time in the HG). The tests were also used to compare the same variables between the HG and CG group. The groups' only difference was the presence of radiographic signs of OA. In the HG the number of joints with radiographic degenerative changes increased significantly over time and was significantly higher than the CG. Clinically and functionally, the HG and CG did not differ. Therefore, it is concluded that TMJ hypermobility is a subsidiary factor in the development of TMJ OA. PMID:8118897

  4. [Total temporomandibular joint prostheses].

    PubMed

    Zwetyenga, N; Amroun, S; Wajszczak, B-L; Moris, V

    2016-09-01

    The temporomandibular joint (TMJ) is probably the most complex human joint. As in all joints, its prosthetic replacement may be indicated in selected cases. Significant advances have been made in the design of TMJ prostheses during the last three decades and the indications have been clarified. The aim of our work was to make an update on the current total TMJ total joint replacement. Indications, contraindications, prosthetic components, advantages, disadvantages, reasons for failure or reoperation, virtual planning and surgical protocol have been exposed. PMID:27554487

  5. Mechanics of Sheeting Joints

    NASA Astrophysics Data System (ADS)

    Martel, S. J.

    2015-12-01

    Physical breakdown of rock across a broad scale spectrum involves fracturing. In many areas large fractures develop near the topographic surface, with sheeting joints being among the most impressive. Sheeting joints share many geometric, textural, and kinematic features with other joints (opening-mode fractures) but differ in that they are (a) discernibly curved, (b) open near the topographic surface, and (c) form subparallel to the topographic surface. Where sheeting joints are geologically young, the surface-parallel compressive stresses are typically several MPa or greater. Sheeting joints are best developed beneath domes, ridges, and saddles; they also are reported, albeit rarely, beneath valleys or bowls. A mechanism that accounts for all these associations has been sought for more than a century: neither erosion of overburden nor high lateral compressive stresses alone suffices. Sheeting joints are not accounted for by Mohr-Coulomb shear failure criteria. Principles of linear elastic fracture mechanics, together with the mechanical effect of a curved topographic surface, do provide a basis for understanding sheeting joint growth and the pattern sheeting joints form. Compressive stresses parallel to a singly or doubly convex topographic surface induce a tensile stress perpendicular to the surface at shallow depths; in some cases this alone could overcome the weight of overburden to open sheeting joints. If regional horizontal compressive stresses, augmented by thermal stresses, are an order of magnitude or so greater than a characteristic vertical stress that scales with topographic amplitude, then topographic stress perturbations can cause sheeting joints to open near the top of a ridge. This topographic effect can be augmented by pressure within sheeting joints arising from water, ice, or salt. Water pressure could be particularly important in helping drive sheeting joints downslope beneath valleys. Once sheeting joints have formed, the rock sheets between

  6. Compound solder joints

    NASA Technical Reports Server (NTRS)

    Batista, R. I.; Simonson, R. B.

    1976-01-01

    Joining technique prevents contamination, may be used to join dissimilar metal tubes, minimizes fluid and gas entrapment, expedites repairs, and can yield joints having leakage rates less than 0.000001 standard cubic cm He/min. Components of joint are solder sleeve, two solder rings, Teflon sleeve, and tubing to be joined.

  7. Truss Slip Joint

    NASA Technical Reports Server (NTRS)

    Thomas, Frank

    1993-01-01

    Truss slip joint has few parts, strong, and assembled and disassembled easily. Designed to carry axial loads as large as 100,000 lb and to accommodate slight initial axial-displacement and angular misalignments. Joint assembled or disassembled by astronaut in space suit or, on Earth, by technician in heavy protective clothing; simple enough to be operable by robot. Modified to accommodate welding.

  8. Wedge Joints for Trusses

    NASA Technical Reports Server (NTRS)

    Wood, Kenneth E.

    1987-01-01

    Structure assembled rapidly with simple hand tools. Proposed locking wedge joints enable rapid assembly of lightweight beams, towers, scaffolds, and other truss-type structures. Lightweight structure assembled from tubular struts joined at nodes by wedge pins fitting into mating slots. Joint assembled rapidly by seating wedge pin in V-shaped slots and deforming end of strut until primary pawl engages it.

  9. Strategies for joint appointments.

    PubMed

    Royle, J; Crooks, D L

    1985-01-01

    The structure and policies governing joint appointments discussed above, are developed primarily through cooperation and collaboration between nursing service and education institutions. The joint appointee participates in the process of negotiation of salary, benefits and role responsibilities and exploration of the implications of the appointment for personal career development. Implementation and maintenance of the appointment requires the collaborative efforts of the joint appointee with both contracting agencies. Factors influencing the functioning of joint appointees have been identified and strategies to facilitate functioning presented. The joint appointee must be independent in thought and action yet adaptable to work within the boundaries of two social systems with differing values and expectations. Nursing management, peers and students can provide the support needed to overcome the frustrations and to achieve the rewards inherent in successful implementation of an exciting and innovative role. PMID:3852805

  10. [Approach to joint effusion].

    PubMed

    Henniger, M; Rehart, S

    2016-09-01

    The fundamental components of the differential diagnostics of joint effusions are the patient history and clinical examination. In the case of unclear findings, arthrosonography can provide information for the distinction between intra-articular and extra-articular pathologies. In atraumatic joint effusions inflammatory parameters in blood are determined in order to differentiate between systemic inflammatory and local inflammatory joint effusions. In the case of normal values further diagnostics are carried out using imaging. With elevated inflammatory parameters the main differential diagnoses are gouty arthritis, autoimmune joint processes and septic arthritis. When in doubt, a joint aspiration and synovial fluid analysis should be performed to rule out septic arthritis or if necessary confirmation of gouty arthritis. PMID:27562127

  11. MISR JOINT_AS Data

    Atmospheric Science Data Center

    2014-07-21

    Joint Aerosol Product (JOINT_AS) The MISR Level 3 Products are global or regional ... field campaigns at daily and monthly time scales. The Joint Aerosol product provides a monthly global statistical summary of MISR ...

  12. Pressure vessel flex joint

    NASA Technical Reports Server (NTRS)

    Kahn, Jon B. (Inventor)

    1992-01-01

    An airtight, flexible joint is disclosed for the interfacing of two pressure vessels such as between the Space Station docking tunnel and the Space Shuttle Orbiter bulkhead adapter. The joint provides for flexibility while still retaining a structural link between the two vessels required due to the loading created by the internal/external pressure differential. The joint design provides for limiting the axial load carried across the joint to a specific value, a function returned in the Orbiter/Station tunnel interface. The flex joint comprises a floating structural segment which is permanently attached to one of the pressure vessels through the use of an inflatable seal. The geometric configuration of the joint causes the tension between the vessels created by the internal gas pressure to compress the inflatable seal. The inflation pressure of the seal is kept at a value above the internal/external pressure differential of the vessels in order to maintain a controlled distance between the floating segment and pressure vessel. The inflatable seal consists of either a hollow torus-shaped flexible bladder or two rolling convoluted diaphragm seals which may be reinforced by a system of straps or fabric anchored to the hard structures. The joint acts as a flexible link to allow both angular motion and lateral displacement while it still contains the internal pressure and holds the axial tension between the vessels.

  13. Compliant Joints For Robots

    NASA Technical Reports Server (NTRS)

    Kerley, James J., Jr.

    1990-01-01

    Compliant joints devised to accommodate misalignments of tools and/or workpieces with respect to robotic manipulators. Has characteristics and appearance of both universal-joint and cable-spring-type flexible shaft coupling. Compliance derived from elastic properties of short pieces of cable. Compliance of joint determined by lengths, distances between, relative orientations, thickness of strands, number of strands, material, amount of pretwist, and number of short pieces of cable. Worm-drive mechanism used to adjust lengths to vary compliance as needed during operation.

  14. Total ankle joint replacement.

    PubMed

    2016-02-01

    Ankle arthritis results in a stiff and painful ankle and can be a major cause of disability. For people with end-stage ankle arthritis, arthrodesis (ankle fusion) is effective at reducing pain in the shorter term, but results in a fixed joint, and over time the loss of mobility places stress on other joints in the foot that may lead to arthritis, pain and dysfunction. Another option is to perform a total ankle joint replacement, with the aim of giving the patient a mobile and pain-free ankle. In this article we review the efficacy of this procedure, including how it compares to ankle arthrodesis, and consider the indications and complications.

  15. Knee joint replacement

    MedlinePlus

    ... is used to attach this part. Repair your muscles and tendons around the new joint and close the surgical cut. The surgery takes about 2 hours. Most artificial knees have both metal and plastic parts. Some ...

  16. Wrist joint assembly

    NASA Technical Reports Server (NTRS)

    Kersten, L.; Johnson, J. D. (Inventor)

    1978-01-01

    A wrist joint assembly is provided for use with a mechanical manipulator arm for finely positioning an end-effector carried by the wrist joint on the terminal end of the manipulator arm. The wrist joint assembly is pivotable about a first axis to produce a yaw motion, a second axis is to produce a pitch motion, and a third axis to produce a roll motion. The wrist joint assembly includes a disk segment affixed to the terminal end of the manipulator arm and a first housing member, a second housing member, and a third housing member. The third housing member and the mechanical end-effector are moved in the yaw, pitch, and roll motion. Drive means are provided for rotating each of the housings about their respective axis which includes a cluster of miniature motors having spur gears carried on the output drive shaft which mesh with a center drive gear affixed on the housing to be rotated.

  17. Improved orthopedic arm joint

    NASA Technical Reports Server (NTRS)

    Dane, D. H.

    1971-01-01

    Joint permits smooth and easy movement of disabled arm and is smaller, lighter and less expensive than previous models. Device is interchangeable and may be used on either arm at the shoulder or at the elbow.

  18. Joint fluid Gram stain

    MedlinePlus

    Gram stain of joint fluid ... result means no bacteria are present on the Gram stain. Normal value ranges may vary slightly among ... Abnormal results mean bacteria were seen on the Gram stain. This may be a sign of a ...

  19. Scaling in Columnar Joints

    NASA Astrophysics Data System (ADS)

    Morris, Stephen

    2007-03-01

    Columnar jointing is a fracture pattern common in igneous rocks in which cracks self-organize into a roughly hexagonal arrangement, leaving behind an ordered colonnade. We report observations of columnar jointing in a laboratory analog system, desiccated corn starch slurries. Using measurements of moisture density, evaporation rates, and fracture advance rates, we suggest an advective-diffusive system is responsible for the rough scaling behavior of columnar joints. This theory explains the order of magnitude difference in scales between jointing in lavas and in starches. We investigated the scaling of average columnar cross-sectional areas in experiments where the evaporation rate was fixed using feedback methods. Our results suggest that the column area at a particular depth is related to both the current conditions, and hysteretically to the geometry of the pattern at previous depths. We argue that there exists a range of stable column scales allowed for any particular evaporation rate.

  20. Hip joint injection

    MedlinePlus

    ... injected so the provider can see where to place the medicine. The steroid medicine is slowly injected into the joint. After the injection, you will remain on the table for another 5 to 10 minutes or so. ...

  1. Temporomandibular Joint Disorder

    MedlinePlus

    ... 2008 Previous Next Related Articles: Temporomandibular Joint Disorder (TMD) Are You Biting Off More Than You Can Chew? Equilibration May Lessen TMD Pain Fender-benders: Source of TMD? First Comes ...

  2. Panel Post & Diagonal Brace Joint Detail; Crossbracing Center Joint ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Panel Post & Diagonal Brace Joint Detail; Crossbracing Center Joint Detail; Chord, Panel Post, Tie Bar, & Diagonal Brace Joint Detail; Chord, Tie Bar, & Crossbracing Joint Detail - Medora Bridge, Spanning East Fork of White River at State Route 235, Medora, Jackson County, IN

  3. High pressure ceramic joint

    DOEpatents

    Ward, M.E.; Harkins, B.D.

    1993-11-30

    Many recuperators have components which react to corrosive gases and are used in applications where the donor fluid includes highly corrosive gases. These recuperators have suffered reduced life, increased service or maintenance, and resulted in increased cost. The present joint when used with recuperators increases the use of ceramic components which do not react to highly corrosive gases. Thus, the present joint used with the present recuperator increases the life, reduces the service and maintenance, and reduces the increased cost associated with corrosive action of components used to manufacture recuperators. The present joint is comprised of a first ceramic member, a second ceramic member, a mechanical locking device having a groove defined in one of the first ceramic member and the second ceramic member. The joint and the mechanical locking device is further comprised of a refractory material disposed in the groove and contacting the first ceramic member and the second ceramic member. The present joint mechanically provides a high strength load bearing joint having good thermal cycling characteristics, good resistance to a corrosive environment and good steady state strength at elevated temperatures. 4 figures.

  4. High pressure ceramic joint

    DOEpatents

    Ward, Michael E.; Harkins, Bruce D.

    1993-01-01

    Many recuperators have components which react to corrosive gases and are used in applications where the donor fluid includes highly corrosive gases. These recuperators have suffered reduced life, increased service or maintenance, and resulted in increased cost. The present joint when used with recuperators increases the use of ceramic components which do not react to highly corrosive gases. Thus, the present joint used with the present recuperator increases the life, reduces the service and maintenance, and reduces the increased cost associated with corrosive action of components used to manufacture recuperators. The present joint is comprised of a first ceramic member, a second ceramic member, a mechanical locking device having a groove defined in one of the first ceramic member and the second ceramic member. The joint and the mechanical locking device is further comprised of a refractory material disposed in the groove and contacting the first ceramic member and the second ceramic member. The present joint mechanically provides a high strength load bearing joint having good thermal cycling characteristics, good resistance to a corrosive environment and good steady state strength at elevated temperatures.

  5. [Biomechanics of the ankle joint].

    PubMed

    Zwipp, H

    1989-03-01

    According to Fick, the tree-dimensional patterns of foot motion are best characterized as jawlike movement. Anatomically and biomechanically, this process represents conjoined, synchronous motion within the three mobile segments of the hindfoot: the ankle joint, the posterior subtalar joint, and the anterior subtalar joint. Foot kinematics can be described more completely if the anterior subtalar joint is defined not only as the talocalcaneal navicular joint, but as including the calcaneocuboid joint, thus representing the transverse joint of the tarsus, i.e., the Chopart joint. The axes of these three joints can be defined precisely. In some parts they represent a screwlike motion, clockwise or counter-clockwise, around the central ligamentous structures (fibulotibial ligament, talocalcaneal interosseous ligament, bifurcate ligament). The individual anatomy and structure of these ligaments provide variations in the degree and direction of foot motion. A precise knowledge of foot kinematics is important in surgical ligament and joint reconstruction and in selective foot arthrodeses.

  6. Joint ventures in medical services.

    PubMed

    Rublee, D A

    1987-01-01

    This paper is an overview of joint-venture activity in healthcare, describing trends in joint ventures and raising issues for physicians. The purposes are to discuss the major current facets of joint-venture alliances in healthcare and to identify policy issues that arise from the trend to use joint ventures as an organizational tool. Speculation is made about the future role of joint ventures in the organization of healthcare.

  7. Dissimilar metals joint evaluation

    NASA Technical Reports Server (NTRS)

    Wakefield, M. E.; Apodaca, L. E.

    1974-01-01

    Dissimilar metals tubular joints between 2219-T851 aluminum alloy and 304L stainless steel were fabricated and tested to evaluate bonding processes. Joints were fabricated by four processes: (1) inertia (friction) weldings, where the metals are spun and forced together to create the weld; (2) explosive welding, where the metals are impacted together at high velocity; (3) co-extrusion, where the metals are extruded in contact at high temperature to promote diffusion; and (4) swaging, where residual stresses in the metals after a stretching operation maintain forced contact in mutual shear areas. Fifteen joints of each type were prepared and evaluated in a 6.35 cm (2.50 in.) O.D. size, with 0.32 cm (0.13 in.) wall thickness, and 7.6 cm (3.0 in) total length. The joints were tested to evaluate their ability to withstand pressure cycle, thermal cycle, galvanic corrosion and burst tests. Leakage tests and other non-destructive test techniques were used to evaluate the behavior of the joints, and the microstructure of the bond areas was analyzed.

  8. Prosthetic Joint Infection

    PubMed Central

    Tande, Aaron J.

    2014-01-01

    SUMMARY Prosthetic joint infection (PJI) is a tremendous burden for individual patients as well as the global health care industry. While a small minority of joint arthroplasties will become infected, appropriate recognition and management are critical to preserve or restore adequate function and prevent excess morbidity. In this review, we describe the reported risk factors for and clinical manifestations of PJI. We discuss the pathogenesis of PJI and the numerous microorganisms that can cause this devastating infection. The recently proposed consensus definitions of PJI and approaches to accurate diagnosis are reviewed in detail. An overview of the treatment and prevention of this challenging condition is provided. PMID:24696437

  9. Joint Custody and Coparenting.

    ERIC Educational Resources Information Center

    Sell, Kenneth D.

    Results are presented of an intensive search of U.S. newspapers and periodicals on the joint custody of children after divorce, where both parents have continued responsibility for parenting and where the children spend part of each week, month, or year with both of the parents. Areas of concern addressed by these materials include the following:…

  10. Human temporomandibular joint morphogenesis.

    PubMed

    Carini, Francesco; Scardina, Giuseppe Alessandro; Caradonna, Carola; Messina, Pietro; Valenza, Vincenzo

    2007-01-01

    Temporomandibular joint morphogenesis was studied. Ranging in age of fetuses examined was from 6 to14 weeks' gestation. Our results showed the condyle so first element that appear between 6 degrees and 8 degrees week (condylar blastema). After a week appear temporal elements. Disk appear at the same time of glenoid blastema and it reaches an advanced differentation before of the condyle and temporal element, so these don't effect machanical compression on mesenchyma where we find the disk. So we think that the disk result of genetic expression and it isn't the result of mechanical compression. The inferior joint cavity appear to 12 week. The superior joint cavity appear to 13-14 week. In conclusion, the appearance of the condyle is the first event during TMJ morphogenesis, with its initial bud, in form of a mesenchymal thickening, becoming detectable between the sixth and eight week of development, when all the large joints of the limbs are already well defined. PMID:18333411

  11. Clad metal joint closure

    SciTech Connect

    Siebert, O.W.

    1985-04-09

    A plasma arc spray overlay of cladding metals is used over joints between clad metal pieces to provide a continuous cladding metal surface. The technique permits applying an overlay of a high melting point cladding metal to a cladding metal surface without excessive heating of the backing metal.

  12. New Joint Sealants. Criteria, Design and Materials.

    ERIC Educational Resources Information Center

    Building Research Inst., Inc., Washington, DC.

    Contents include--(1) sealing concrete joints, (2) sealing glass and metal joints, (3) metal and glass joint sealants from a fabricator's viewpoint, (4) a theory of adhesion for joint sealants, (5) geometry of simple joint seals under strain, (6) joint sealant specifications from a manufacturer's viewpoint, (7) joint sealant requirements from an…

  13. Anaerobic prosthetic joint infection.

    PubMed

    Shah, Neel B; Tande, Aaron J; Patel, Robin; Berbari, Elie F

    2015-12-01

    In an effort to improve mobility and alleviate pain from degenerative and connective tissue joint disease, an increasing number of individuals are undergoing prosthetic joint replacement in the United States. Joint replacement is a highly effective intervention, resulting in improved quality of life and increased independence [1]. By 2030, it is predicted that approximately 4 million total hip and knee arthroplasties will be performed yearly in the United States [2]. One of the major complications associated with this procedure is prosthetic joint infection (PJI), occurring at a rate of 1-2% [3-7]. In 2011, the Musculoskeletal Infectious Society created a unifying definition for prosthetic joint infection [8]. The following year, the Infectious Disease Society of America published practice guidelines that focused on the diagnosis and management of PJI. These guidelines focused on the management of commonly encountered organisms associated with PJI, including staphylococci, streptococci and select aerobic Gram-negative bacteria. However, with the exception of Propionibacterium acnes, management of other anaerobic organisms was not addressed in these guidelines [1]. Although making up approximately 3-6% of PJI [9,10], anaerobic microorganisms cause devastating complications, and similar to the more common organisms associated with PJI, these bacteria also result in significant morbidity, poor outcomes and increased health-care costs. Data on diagnosis and management of anaerobic PJI is mostly derived from case reports, along with a few cohort studies [3]. There is a paucity of published data outlining factors associated with risks, diagnosis and management of anaerobic PJI. We therefore reviewed available literature on anaerobic PJI by systematically searching the PubMed database, and collected data from secondary searches to determine information on pathogenesis, demographic data, clinical features, diagnosis and management. We focused our search on five commonly

  14. Shoulder Joint For Protective Suit

    NASA Technical Reports Server (NTRS)

    Kosmo, Joseph J.; Smallcombe, Richard D.

    1994-01-01

    Shoulder joint allows full range of natural motion: wearer senses little or no resisting force or torque. Developed for space suit, joint offers advantages in protective garments for underwater work, firefighting, or cleanup of hazardous materials.

  15. Determination of Parachute Joint Factors using Seam and Joint Testing

    NASA Technical Reports Server (NTRS)

    Mollmann, Catherine

    2015-01-01

    This paper details the methodology for determining the joint factor for all parachute components. This method has been successfully implemented on the Capsule Parachute Assembly System (CPAS) for the NASA Orion crew module for use in determining the margin of safety for each component under peak loads. Also discussed are concepts behind the joint factor and what drives the loss of material strength at joints. The joint factor is defined as a "loss in joint strength...relative to the basic material strength" that occurs when "textiles are connected to each other or to metals." During the CPAS engineering development phase, a conservative joint factor of 0.80 was assumed for each parachute component. In order to refine this factor and eliminate excess conservatism, a seam and joint testing program was implemented as part of the structural validation. This method split each of the parachute structural joints into discrete tensile tests designed to duplicate the loading of each joint. Breaking strength data collected from destructive pull testing was then used to calculate the joint factor in the form of an efficiency. Joint efficiency is the percentage of the base material strength that remains after degradation due to sewing or interaction with other components; it is used interchangeably with joint factor in this paper. Parachute materials vary in type-mainly cord, tape, webbing, and cloth -which require different test fixtures and joint sample construction methods. This paper defines guidelines for designing and testing samples based on materials and test goals. Using the test methodology and analysis approach detailed in this paper, the minimum joint factor for each parachute component can be formulated. The joint factors can then be used to calculate the design factor and margin of safety for that component, a critical part of the design verification process.

  16. Achieving joint benefits from joint implementation

    SciTech Connect

    Moomaw, W.R.

    1995-11-01

    Joint Implementation (JI) appears to have been born with Applied Energy Services Guatemala project in 1988. That project, to plant 52 million trees, protect existing forests from cutting and fire, and enhance rural development, is being implemented by CARE Guatemala to offset 120 per cent of the emissions of a small coal burning power plant that has been built in Connecticut. Since that time, several utilities and governments have initiated additional projects. Not all of these necessarily consist of tree planting in other countries, but may consist of energy efficiency or energy conservation programs designed to reduce carbon emissions by at least as much as the additional releases from a new facility. All JI projects share the characteristic of linking the release of greenhouse gases in an industrial country with an offset that reduces or absorbs a comparable amount in another country. The emitter in the industrial country is willing to pay for the reduction elsewhere because costs are less than they would be at home.

  17. Phase 1 Program Joint Report

    NASA Technical Reports Server (NTRS)

    Nield, George C. (Editor); Vorobiev, Pavel Mikhailovich (Editor)

    1999-01-01

    This report consists of inputs from each of the Phase I Program Joint Working Groups. The Working Groups were tasked to describe the organizational structure and work processes that they used during the program, joint accomplishments, lessons learned, and applications to the International Space Station Program. This report is a top-level joint reference document that contains information of interest to both countries.

  18. Double slotted socket spherical joint

    DOEpatents

    Bieg, Lothar F.; Benavides, Gilbert L.

    2001-05-22

    A new class of spherical joints is disclosed. These spherical joints are capable of extremely large angular displacements (full cone angles in excess of 270.degree.), while exhibiting no singularities or dead spots in their range of motion. These joints can improve or simplify a wide range of mechanical devices.

  19. Swivel Joint For Liquid Nitrogen

    NASA Technical Reports Server (NTRS)

    Milner, James F.

    1988-01-01

    Swivel joint allows liquid-nitrogen pipe to rotate through angle of 100 degree with respect to mating pipe. Functions without cracking hard foam insulation on lines. Pipe joint rotates on disks so mechanical stress not transmitted to thick insulation on pipes. Inner disks ride on fixed outer disks. Disks help to seal pressurized liquid nitrogen flowing through joint.

  20. Joint hypermobility syndrome pain.

    PubMed

    Grahame, Rodney

    2009-12-01

    Joint hypermobility syndrome (JHS) was initially defined as the occurrence of musculoskeletal symptoms in the presence of joint laxity and hypermobility in otherwise healthy individuals. It is now perceived as a commonly overlooked, underdiagnosed, multifaceted, and multisystemic heritable disorder of connective tissue (HDCT), which shares many of the phenotypic features of other HDCTs such as Marfan syndrome and Ehlers-Danlos syndrome. Whereas the additional flexibility can confer benefits in terms of mobility and agility, adverse effects of tissue laxity and fragility can give rise to clinical consequences that resonate far beyond the confines of the musculoskeletal system. There is hardly a clinical specialty to be found that is not touched in one way or another by JHS. Over the past decade, it has become evident that of all the complications that may arise in JHS, chronic pain is arguably the most menacing and difficult to treat. PMID:19889283

  1. Laundry joint venture.

    PubMed

    Giancola, D; Voyvodich, M

    1984-12-01

    Many hospitals are concerned about the loss of control which is associated with contracting for linen service. On the the hand, many laundries do not have the resources or experience to serve hospitals in a comprehensive and trouble-free manner. In many communities a joint venture, such as the one described here, can successfully combine the interests of the hospital and laundry communities without causing the hospitals to lose control of the service and without requiring the laundry operator to have detailed knowledge of hospital operations. As more hospitals opt for contract service, and if this service is to be provided at the lowest total cost, the hospitals and the laundries must come to grips with the problems surrounding the laundry-hospital interface. A joint venture, such as that described here, is one way to accomplish this.

  2. Analysis of minor fractures associated with joints and faulted joints

    NASA Astrophysics Data System (ADS)

    Cruikshank, Kenneth M.; Zhao, Guozhu; Johnson, Arvid M.

    In this paper, we use fracture mechanics to interpret conditions responsible for secondary cracks that adorn joints and faulted joints in the Entrada Sandstone in Arches National Park, U.S.A. Because the joints in most places accommodated shearing offsets of a few mm to perhaps 1 dm, and thus became faulted joints, some of the minor cracks are due to faulting. However, in a few places where the shearing was zero, one can examine minor cracks due solely to interaction of joint segments at the time they formed. We recognize several types of minor cracks associated with subsequent faulting of the joints. One is the kink, a crack that occurs at the termination of a straight joint and whose trend is abruptly different from that of the joint. Kinks are common and should be studied because they contain a great deal of information about conditions during fracturing. The sense of kinking indicates the sense of shear during faulting: a kink that turns clockwise with respect to the direction of the main joint is a result of right-lateral shear, and a kink that turns counterclockwise is a result of left-lateral shear. Furthermore, the kink angle is related to the ratio of the shear stress responsible for the kinking to the normal stress responsible for the opening of the joint. The amount of opening of a joint at the time it faulted or even at the time the joint itself formed can be estimated by measuring the kink angle and the amount of strike-slip at some point along the faulted joint. Other fractures that form near terminations of pre-existing joints in response to shearing along the joint are horsetail fractures. Similar short fractures can occur anywhere along the length of the joints. The primary value in recognizing these fractures is that they indicate the sense of faulting accommodated by the host fracture and the direction of maximum tension. Even where there has been insignificant regional shearing in the Garden Area, the joints can have ornate terminations. Perhaps

  3. Temporomandibular joint dislocation

    PubMed Central

    Sharma, Naresh Kumar; Singh, Akhilesh Kumar; Pandey, Arun; Verma, Vishal; Singh, Shreya

    2015-01-01

    Temporomandibular joint (TMJ) dislocation is an uncommon but debilitating condition of the facial skeleton. The condition may be acute or chronic. Acute TMJ dislocation is common in clinical practice and can be managed easily with manual reduction. Chronic recurrent TMJ dislocation is a challenging situation to manage. In this article, we discuss the comprehensive review of the different treatment modalities in managing TMJ dislocation. PMID:26668447

  4. Prosthetic elbow joint

    NASA Technical Reports Server (NTRS)

    Weddendorf, Bruce C. (Inventor)

    1994-01-01

    An artificial, manually positionable elbow joint for use in an upper extremity, above-elbow, prosthetic is described. The prosthesis provides a locking feature that is easily controlled by the wearer. The instant elbow joint is very strong and durable enough to withstand the repeated heavy loadings encountered by a wearer who works in an industrial, construction, farming, or similar environment. The elbow joint of the present invention comprises a turntable, a frame, a forearm, and a locking assembly. The frame generally includes a housing for the locking assembly and two protruding ears. The forearm includes an elongated beam having a cup-shaped cylindrical member at one end and a locking wheel having a plurality of holes along a circular arc on its other end with a central bore for pivotal attachment to the protruding ears of the frame. The locking assembly includes a collar having a central opening with a plurality of internal grooves, a plurality of internal cam members each having a chamfered surface at one end and a V-shaped slot at its other end; an elongated locking pin having a crown wheel with cam surfaces and locking lugs secured thereto; two coiled compression springs; and a flexible filament attached to one end of the elongated locking pin and extending from the locking assembly for extending and retracting the locking pin into the holes in the locking wheel to permit selective adjustment of the forearm relative to the frame. In use, the turntable is affixed to the upper arm part of the prosthetic in the conventional manner, and the cup-shaped cylindrical member on one end of the forearm is affixed to the forearm piece of the prosthetic in the conventional manner. The elbow joint is easily adjusted and locked between maximum flex and extended positions.

  5. Acromioclavicular joint disorders.

    PubMed

    Turnbull, J R

    1998-04-01

    The acromioclavicular joint is commonly involved in athletic injuries. Most commonly, a sprain to the joint occurs with variability in the amount of ligamentous damage and displacement that occurs. In all but the most severe dislocations, treatment consists of initial sling immobilization and early functional rehabilitation. The outcome is usually excellent with full return of function following these injuries. The rarer types (IV, V, and VI) require operative reduction and fixation. Distal clavicle fractures are related injuries, which many times disrupt the stabilizing ligaments of the acromioclavicular joint. Many can be treated nonoperatively, but there are several subtypes that should be considered for early fixation to reduce complications of pain and shoulder dysfunction. An atraumatic, overuse condition, which is becoming more prevalent and seems related to weight training, is osteolysis of the distal clavicle. There is insidious onset of shoulder pain with symptoms and signs consistent with acromioclavicular pathology. Activity modification is the best method of controlling symptoms. Failure of the conservative approach necessitates operative excision of the distal clavicle.

  6. 49 CFR 213.351 - Rail joints.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Rail joints. 213.351 Section 213.351... Rail joints. (a) Each rail joint, insulated joint, and compromise joint shall be of a structurally sound design and dimensions for the rail on which it is applied. (b) If a joint bar is cracked,...

  7. 17 CFR 300.105 - Joint accounts.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 17 Commodity and Securities Exchanges 4 2014-04-01 2014-04-01 false Joint accounts. 300.105... Customers of Sipc Members § 300.105 Joint accounts. (a) A joint account shall be deemed to be a “qualifying joint account” if it is owned jointly, whether by the owners thereof as joint tenants with the right...

  8. 17 CFR 300.105 - Joint accounts.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 17 Commodity and Securities Exchanges 3 2012-04-01 2012-04-01 false Joint accounts. 300.105... Customers of Sipc Members § 300.105 Joint accounts. (a) A joint account shall be deemed to be a “qualifying joint account” if it is owned jointly, whether by the owners thereof as joint tenants with the right...

  9. 17 CFR 300.105 - Joint accounts.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 17 Commodity and Securities Exchanges 3 2011-04-01 2011-04-01 false Joint accounts. 300.105... Customers of Sipc Members § 300.105 Joint accounts. (a) A joint account shall be deemed to be a “qualifying joint account” if it is owned jointly, whether by the owners thereof as joint tenants with the right...

  10. 17 CFR 300.105 - Joint accounts.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 17 Commodity and Securities Exchanges 3 2013-04-01 2013-04-01 false Joint accounts. 300.105... Customers of Sipc Members § 300.105 Joint accounts. (a) A joint account shall be deemed to be a “qualifying joint account” if it is owned jointly, whether by the owners thereof as joint tenants with the right...

  11. 49 CFR 213.351 - Rail joints.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Rail joints. 213.351 Section 213.351... Rail joints. (a) Each rail joint, insulated joint, and compromise joint shall be of a structurally sound design and dimensions for the rail on which it is applied. (b) If a joint bar is cracked,...

  12. 49 CFR 213.351 - Rail joints.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Rail joints. 213.351 Section 213.351... Rail joints. (a) Each rail joint, insulated joint, and compromise joint shall be of a structurally sound design and dimensions for the rail on which it is applied. (b) If a joint bar is cracked,...

  13. 49 CFR 213.351 - Rail joints.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Rail joints. 213.351 Section 213.351... Rail joints. (a) Each rail joint, insulated joint, and compromise joint shall be of a structurally sound design and dimensions for the rail on which it is applied. (b) If a joint bar is cracked,...

  14. 49 CFR 213.351 - Rail joints.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Rail joints. 213.351 Section 213.351... Rail joints. (a) Each rail joint, insulated joint, and compromise joint shall be of a structurally sound design and dimensions for the rail on which it is applied. (b) If a joint bar is cracked,...

  15. 17 CFR 300.105 - Joint accounts.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false Joint accounts. 300.105... Customers of Sipc Members § 300.105 Joint accounts. (a) A joint account shall be deemed to be a “qualifying joint account” if it is owned jointly, whether by the owners thereof as joint tenants with the right...

  16. Influence of joint topology on the formation of brazed joints

    NASA Astrophysics Data System (ADS)

    Sekulic, Dusan P.; Zellmer, Benjamin P.; Nigro, Nicholas

    2001-09-01

    This paper discusses the influence of joint topology on the formation of brazed joints. For the purposes of this study, the joint topology is defined by dimensionless parameters that characterize: (i) the geometry of the mating surfaces (shape and configuration), (ii) the gap between bonded parts (clearance and tolerances), (iii) the joint orientation in the gravity field and (iv) the volume of the joint. The influence of these parameters is presented for several joints with a topology that is typically found in the manufacture of compact heat exchangers. The results were obtained by employing a method that is based on a variational principle and minimization of the potential energy of the molten aluminium liquid metal just prior to the onset of solidification. The method, which was verified by comparison with experimental data obtained from controlled atmosphere brazing of aluminium alloys, is discussed in an accompanying paper.

  17. Joint hypermobility syndrome.

    PubMed

    Fikree, Asma; Aziz, Qasim; Grahame, Rodney

    2013-05-01

    Although perceived as a rare condition, joint hypermobility syndrome is common. Its prevalence in rheumatology clinics is extremely high. Early estimates suggest that it may be the most common of all rheumatologic conditions. The problem lies in the general lack of awareness of the syndrome, its means of recognition, and the resultant failure to diagnose it correctly when present. It is a worldwide problem. This article provides an overview of hypermobility and hypermobility syndrome, stressing its multisystemic nature and the negative impact that it may have on quality of life, with particular reference to gastrointestinal involvement. PMID:23597972

  18. Acromioclavicular Joint Reconstruction.

    PubMed

    Scillia, Anthony J; Cain, E Lyle

    2015-12-01

    Our technique for acromioclavicular joint reconstruction provides a variation on coracoclavicular ligament reconstruction to also include acromioclavicular ligament reconstruction. An oblique acromial tunnel is drilled, and the medial limb of the gracilis graft, after being crossed and passed beneath the coracoid and through the clavicle, is passed through this acromial tunnel and sutured to the trapezoid graft limb after appropriate tensioning. Tenodesis screws are not placed in the bone tunnels to avoid graft fraying, and initial forces on the graft are offloaded with braided absorbable sutures passed around the clavicle. PMID:27284528

  19. Arthroscopy and joint lavage.

    PubMed

    Ayral, Xavier

    2005-06-01

    Arthroscopy is used by rheumatologists for research purposes in cases with knee osteoarthritis and inflammatory arthritis. This chapter explains the technical characteristics of 'research arthroscopy' including the simplification of the procedure, video-recording, as well as risks and training. Lavage of the knee joint is proposed as a treatment procedure for osteoarthritis and inflammatory and septic arthritis. Tidal irrigation and the two-needle technique of lavage are described. In the absence of clear predictive factors for efficacy, the indications for these techniques are a matter of debate. PMID:15939366

  20. Joint bone radiobiology workshop

    SciTech Connect

    Tomich, P.A.

    1991-01-01

    The Joint Bone Radiobiology Workshop was held on July 12--13, 1991 in Toronto, Canada. This document contains the papers presented at the meeting. The five sections were: Dose-effects, Endogenous Cofactors, Tumorigenesis, New Methods and Medical Implications. The papers covered risk assessment, tissue distribution of radionuclides, lifetime studies, biological half-lifes, the influence of age at time of exposure, tumor induction by different radionuclides, microscopic localization of radionuclides, and nuclear medicine issues including tissue distribution in the skeleton and bone marrow transplantation. (MHB)

  1. Surgery center joint ventures.

    PubMed

    Zasa, R J

    1999-01-01

    Surgery centers have been accepted as a cost effective, patient friendly vehicle for delivery of quality ambulatory care. Hospitals and physician groups also have made them the vehicles for coming together. Surgery centers allow hospitals and physicians to align incentives and share benefits. It is one of the few types of health care businesses physicians can own without anti-fraud and abuse violation. As a result, many surgery center ventures are now jointly owned by hospitals and physician groups. This article outlines common structures that have been used successfully to allow both to own and govern surgery centers.

  2. Glenohumeral Joint Injections

    PubMed Central

    Gross, Christopher; Dhawan, Aman; Harwood, Daniel; Gochanour, Eric; Romeo, Anthony

    2013-01-01

    Context: Intra-articular injections into the glenohumeral joint are commonly performed by musculoskeletal providers, including orthopaedic surgeons, family medicine physicians, rheumatologists, and physician assistants. Despite their frequent use, there is little guidance for injectable treatments to the glenohumeral joint for conditions such as osteoarthritis, adhesive capsulitis, and rheumatoid arthritis. Evidence Acquisition: We performed a comprehensive review of the available literature on glenohumeral injections to help clarify the current evidence-based practice and identify deficits in our understanding. We searched MEDLINE (1948 to December 2011 [week 1]) and EMBASE (1980 to 2011 [week 49]) using various permutations of intra-articular injections AND (corticosteroid OR hyaluronic acid) and (adhesive capsulitis OR arthritis). Results: We identified 1 and 7 studies that investigated intra-articular corticosteroid injections for the treatment of osteoarthritis and adhesive capsulitis, respectively. Two and 3 studies investigated the use of hyaluronic acid in osteoarthritis and adhesive capsulitis, respectively. One study compared corticosteroids and hyaluronic acid injections in the treatment of osteoarthritis, and another discussed adhesive capsulitis. Conclusion: Based on existing studies and their level of evidence, there is only expert opinion to guide corticosteroid injection for osteoarthritis as well as hyaluronic acid injection for osteoarthritis and adhesive capsulitis. PMID:24427384

  3. The acromioclavicular joint.

    PubMed

    Montellese, Phyllis; Dancy, Timothy

    2004-12-01

    Acute injuries of the AC joint have a limited differential diagnosis. A thorough examination and appropriate radiographs can identify nearly all problems while ruling out tumors as a causal factor. AC injury frequently occurs with other fractures, dislocations, or soft tissue injury around the shoulder. The single unifying diagnosis one searches for in medical conditions is frequently absent in musculoskeletal injury. For effective management of AC separations, the primary care physician need only distinguish type I, II, and III injuries from surgically treated type IV, V, and VI injuries. Types I, II, and III injuries should be treated with pain control and progressive rehabilitation as described previously. Patients who have types IV, V, and VI injuries should be referred to an orthopedic surgeon. Chronic injuries of the AC joint are also clearly diagnosed by appropriate physical examination and radiographs. Steroid injections can aid in the diagnosis and management of these conditions. Injury to one shoulder component predisposes to other shoulder injuries. A thorough examination will reveal these other associated abnormalities that may not be part of the presenting complaint. With practice in the examination of the shoulder and intra-articular injections, the primary care physician can effectively treat most common AC conditions. Only after conservative measures fail is it necessary to refer the patient for surgical management.

  4. Jointly Sponsored Research Program

    SciTech Connect

    Everett A. Sondreal; John G. Hendrikson; Thomas A. Erickson

    2009-03-31

    U.S. Department of Energy (DOE) Cooperative Agreement DE-FC26-98FT40321 funded through the Office of Fossil Energy and administered at the National Energy Technology Laboratory (NETL) supported the performance of a Jointly Sponsored Research Program (JSRP) at the Energy & Environmental Research Center (EERC) with a minimum 50% nonfederal cost share to assist industry in commercializing and effectively applying highly efficient, nonpolluting energy systems that meet the nation's requirements for clean fuels, chemicals, and electricity in the 21st century. The EERC in partnership with its nonfederal partners jointly performed 131 JSRP projects for which the total DOE cost share was $22,716,634 (38%) and the nonfederal share was $36,776,573 (62%). Summaries of these projects are presented in this report for six program areas: (1) resource characterization and waste management, (2) air quality assessment and control, (3) advanced power systems, (4) advanced fuel forms, (5) value-added coproducts, and (6) advanced materials. The work performed under this agreement addressed DOE goals for reductions in CO{sub 2} emissions through efficiency, capture, and sequestration; near-zero emissions from highly efficient coal-fired power plants; environmental control capabilities for SO{sub 2}, NO{sub x}, fine respirable particulate (PM{sub 2.5}), and mercury; alternative transportation fuels including liquid synfuels and hydrogen; and synergistic integration of fossil and renewable resources.

  5. Metal to ceramic sealed joint

    DOEpatents

    Lasecki, J.V.; Novak, R.F.; McBride, J.R.

    1991-08-27

    A metal to ceramic sealed joint which can withstand wide variations in temperature and maintain a good seal is provided for use in a device adapted to withstand thermal cycling from about 20 to about 1000 degrees C. The sealed joint includes a metal member, a ceramic member having an end portion, and an active metal braze forming a joint to seal the metal member to the ceramic member. The joint is positioned remote from the end portion of the ceramic member to avoid stresses at the ends or edges of the ceramic member. The sealed joint is particularly suited for use to form sealed metal to ceramic joints in a thermoelectric generator such as a sodium heat engine where a solid ceramic electrolyte is joined to metal parts in the system. 11 figures.

  6. Metal to ceramic sealed joint

    DOEpatents

    Lasecki, John V.; Novak, Robert F.; McBride, James R.

    1991-01-01

    A metal to ceramic sealed joint which can withstand wide variations in temperature and maintain a good seal is provided for use in a device adapted to withstand thermal cycling from about 20 to about 1000 degrees C. The sealed joint includes a metal member, a ceramic member having an end portion, and an active metal braze forming a joint to seal the metal member to the ceramic member. The joint is positioned remote from the end portion of the ceramic member to avoid stresses at the ends or edges of the ceramic member. The sealed joint is particularly suited for use to form sealed metal to ceramic joints in a thermoelectric generator such as a sodium heat engine where a solid ceramic electrolyte is joined to metal parts in the system.

  7. Ball-joint grounding ring

    NASA Technical Reports Server (NTRS)

    Aperlo, P. J. A.; Buck, P. A.; Weldon, V. A.

    1981-01-01

    In ball and socket joint where electrical insulator such as polytetrafluoroethylene is used as line to minimize friction, good electrical contact across joint may be needed for lightning protection or to prevent static-charge build-up. Electrical contact is maintained by ring of spring-loaded fingers mounted in socket. It may be useful in industry for cranes, trailers, and other applications requiring ball and socket joint.

  8. OIG targets contractual joint ventures.

    PubMed

    O'Hare, Patrick K

    2003-09-01

    A recent OIG Special Advisory Bulletin raises questions for providers involved in joint ventures. The Bulletin describes several characteristics that the OIG views as potentially suspect, including a referral stream controlled by the provider initiating the joint venture and the use of a wholly owned subsidiary of the provider to bill and collect for services. According to the OIG, profits paid by the subsidiary to the provider owner in such "suspect contractual joint ventures" could constitute illegal remuneration for referrals.

  9. Expression of joint moment in the joint coordinate system.

    PubMed

    Desroches, Guillaume; Chèze, Laurence; Dumas, Raphaël

    2010-11-01

    The question of using the nonorthogonal joint coordinate system (JCS) to report joint moments has risen in the literature. However, the expression of joint moments in a nonorthogonal system is still confusing. The purpose of this paper is to present a method to express any 3D vector in a nonorthogonal coordinate system. The interpretation of these expressions in the JCS is clarified and an example for the 3D joint moment vector at the shoulder and the knee is given. A nonorthogonal projection method is proposed based on the mixed product. These nonorthogonal projections represent, for a 3D joint moment vector, the net mechanical action on the JCS axes. Considering the net mechanical action on each axis seems important in order to assess joint resistance in the JCS. The orthogonal projections of the same 3D joint moment vector on the JCS axes can be characterized as "motor torque." However, this interpretation is dependent on the chosen kinematic model. The nonorthogonal and orthogonal projections of shoulder joint moment during wheelchair propulsion and knee joint moment during walking were compared using root mean squares (rmss). rmss showed differences ranging from 6 N m to 22.3 N m between both projections at the shoulder, while differences ranged from 0.8 N m to 3.0 N m at the knee. Generally, orthogonal projections were of lower amplitudes than nonorthogonal projections at both joints. The orthogonal projection on the proximal or distal coordinates systems represents the net mechanical actions on each axis, which is not the case for the orthogonal projection (i.e., motor torque) on JCS axes. In order to represent the net action at the joint in a JCS, the nonorthogonal projection should be used.

  10. Rotary Joint for Heat Transfer

    NASA Technical Reports Server (NTRS)

    Shauback, R.

    1986-01-01

    Rotary joint exchanges heat between two heat pipes - one rotating and one stationary. Joint accommodates varying heat loads with little temperature drop across interface. According to concept, heat pipe enters center of disklike stationary section of joint. There, wicks in central artery of heat pipe separate into multiple strands that lead to concentric channels on rotaryinterface side of stationary disk. Thin layer of liquid sodium/potassium alloy carries heat from one member of rotary joint to other. Liquid conducts heat efficiently while permitting relative motion between members. Polypropylene rings contain liquid without interfering with rotation.

  11. Variable Joint Elasticities in Running

    NASA Astrophysics Data System (ADS)

    Peter, Stephan; Grimmer, Sten; Lipfert, Susanne W.; Seyfarth, Andre

    In this paper we investigate how spring-like leg behavior in human running is represented at joint level. We assume linear torsion springs in the joints and between the knee and the ankle joint. Using experimental data of the leg dynamics we compute how the spring parameters (stiffness and rest angles) change during gait cycle. We found that during contact the joints reveal elasticity with strongly changing parameters and compare the changes of different parameters for different spring arrangements. The results may help to design and improve biologically inspired spring mechanisms with adjustable parameters.

  12. Joint shape morphogenesis precedes cavitation of the developing hip joint

    PubMed Central

    Nowlan, Niamh C; Sharpe, James

    2014-01-01

    The biology and mechanobiology of joint cavitation have undergone extensive investigation, but we have almost no understanding of the development of joint shape. Joint morphogenesis, the development of shape, has been identified as the ‘least understood aspect of joint formation’ (2005, Birth Defects Res C Embryo Today 75, 237), despite the clinical relevance of shape morphogenesis to postnatal skeletal malformations such as developmental dysplasia of the hip. In this study, we characterise development of early hip joint shape in the embryonic chick using direct capture 3D imaging. Contrary to formerly held assumptions that cavitation precedes morphogenesis in joint development, we have found that the major anatomical features of the adult hip are present at Hamburger Hamilton (HH)32, a full day prior to cavitation of the joint at HH34. We also reveal that the pelvis undergoes significant changes in orientation with respect to the femur, despite the lack of a joint cavity between the rudiments. Furthermore, we have identified the appearance of the ischium and pubis several developmental stages earlier than was previously reported, illustrating the value and importance of direct capture 3D imaging. PMID:24266523

  13. Passive Ball Capture Joint

    NASA Technical Reports Server (NTRS)

    Cloyd, Richard A. (Inventor); Bryan, Thomas C. (Inventor)

    2003-01-01

    A passive ball capture joint has a sleeve with a plurality of bores distributed about a circumference thereof and formed therethrough at an acute angle relative to the sleeve's longitudinal axis. A spring-loaded retainer is slidingly fitted in each bore and is biased such that, if allowed, will extend at least partially into the sleeve to retain a ball therein. A ring, rotatably mounted about the bores, has an interior wall defining a plurality of shaped races that bear against the spring-loaded retainers. A mechanized rotational force producer is coupled to the ring. The ring can be rotated from a first position (that presses the retainers into the sleeve to lock the ball in place) to a second position (that allows the retainers to springback out of the sleeve to release the ball).

  14. CRUCIFORM CONTROL ROD JOINT

    DOEpatents

    Thorp, A.G. II

    1962-08-01

    An invention is described which relates to nuclear reactor control rod components and more particularly to a joint between cruciform control rod members and cruciform control rod follower members. In one embodiment this invention provides interfitting crossed arms at adjacent ends of a control rod and its follower in abutting relation. This holds the members against relative opposite longitudinal movement while a compression member keys the arms against relative opposite rotation around a common axis. Means are also provided for centering the control rod and its follower on a common axis and for selectively releasing the control rod from its follower for the insertion of a replacement of the control rod and reuse of the follower. (AEC)

  15. Corynebacterium Prosthetic Joint Infection

    PubMed Central

    Cazanave, Charles; Greenwood-Quaintance, Kerryl E.; Hanssen, Arlen D.

    2012-01-01

    Identification of Corynebacterium species may be challenging. Corynebacterium species are occasional causes of prosthetic joint infection (PJI), but few data are available on the subject. Based on the literature, C. amycolatum, C. aurimucosum, C. jeikeium, and C. striatum are the most common Corynebacterium species that cause PJI. We designed a rapid PCR assay to detect the most common human Corynebacterium species, with a specific focus on PJI. A polyphosphate kinase gene identified using whole-genome sequence was targeted. The assay differentiates the antibiotic-resistant species C. jeikeium and C. urealyticum from other species in a single assay. The assay was applied to a collection of human Corynebacterium isolates from multiple clinical sources, and clinically relevant species were detected. The assay was then tested on Corynebacterium isolates specifically associated with PJI; all were detected. We also describe the first case of C. simulans PJI. PMID:22337986

  16. Temporomandibular joint vibration in bruxers.

    PubMed

    Li, Xueling; Lin, Xuefeng; Wang, Yan

    2009-07-01

    Temporomandibular joint vibration is considered an important physical sign of joint dysfunction and/or joint pathology. The aim of this study was to compare the difference of joint vibration between bruxers and asymptomatic individuals, evaluate the effect of bruxism on the temporomandibular joint (TMJ) and the association between bruxism and temporomandibular disorders. Twenty-four (24) bruxers and 16 asymptomatic subjects were included in the study. Bilateral joint vibrations with jaw tracking were recorded using a TMJ detecting instrument during rhythmic jaw opening and closing movement. The results showed that the vibratory energy and amplitude of the moderate to severe bruxers were significantly higher than that of the mild bruxers and asymptomatic subjects. The percentage of joint vibration occurrence in asymptomatic subjects, mild bruxers, and moderate to severe bruxers was 75.0%, 77.8%, and 100%, respectively. It was concluded that bruxism might induce abnormal joint vibrations, and that the energy of abnormal vibrations might increase with the degree of bruxism.

  17. Review of Rock Joint Models

    SciTech Connect

    Morris, J P

    2003-06-06

    This report discusses several constitutive models for joint behavior with emphasis upon the experimental data which motivates them. Particular emphasis is placed upon data available for granite. The LDEC joint model is presented in detail and LDEC simulations using this model are compared against data from constant normal stiffness and constant normal load tests.

  18. Robotic joint experiments under ultravacuum

    NASA Technical Reports Server (NTRS)

    Borrien, A.; Petitjean, L.

    1988-01-01

    First, various aspects of a robotic joint development program, including gearbox technology, electromechanical components, lubrication, and test results, are discussed. Secondly, a test prototype of the joint allowing simulation of robotic arm dynamic effects is presented. This prototype is tested under vacuum with different types of motors and sensors to characterize the functional parameters: angular position error, mechanical backlash, gearbox efficiency, and lifetime.

  19. Joint Attention and Early Language.

    ERIC Educational Resources Information Center

    Tomasello, Michael; Farrar, Michael Jeffrey

    1986-01-01

    Findings from studies exploring role of joint attentional focus in children's acquisition of language indicated that language of 24 mothers and their 15- to 21-month-olds inside episodes of joint attentional focus involved more utterances, shorter sentences, more comments, and longer conversations than outside of episodes. Also, object references…

  20. Exercise and the Knee Joint.

    ERIC Educational Resources Information Center

    Clarke, H. Harrison, Ed.

    1976-01-01

    This report by the President's Council on Physical Fitness and Sports examines the effects of various forms of physical exercise on the knee joint which, because of its vulnerability, is especially subject to injury. Discussion centers around the physical characteristics of the joint, commonly used measurements for determining knee stability,…

  1. Structuring managed care joint ventures.

    PubMed

    Williams, L

    1995-08-01

    Providers that undertake joint ventures to secure managed care contracts must understand the important governance, operational, legal, and political issues involved. Careful planning in all these areas can help ensure that the joint venture will meet its goals and avoid problems such as inappropriately negotiated contracts and legal violations.

  2. 14 CFR 27.935 - Shafting joints.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Shafting joints. 27.935 Section 27.935... STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Rotor Drive System § 27.935 Shafting joints. Each universal joint, slip joint, and other shafting joints whose lubrication is necessary for operation must...

  3. 14 CFR 29.935 - Shafting joints.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Shafting joints. 29.935 Section 29.935... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Rotor Drive System § 29.935 Shafting joints. Each universal joint, slip joint, and other shafting joints whose lubrication is necessary for operation...

  4. 7 CFR 97.14 - Joint applicants.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 3 2014-01-01 2014-01-01 false Joint applicants. 97.14 Section 97.14 Agriculture... PLANT VARIETY AND PROTECTION The Application § 97.14 Joint applicants. (a) Joint owners shall file a joint application by signing as joint applicants. (b) If an application for certificate is made by...

  5. 14 CFR 27.935 - Shafting joints.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Shafting joints. 27.935 Section 27.935... STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Rotor Drive System § 27.935 Shafting joints. Each universal joint, slip joint, and other shafting joints whose lubrication is necessary for operation must...

  6. 7 CFR 97.14 - Joint applicants.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 3 2012-01-01 2012-01-01 false Joint applicants. 97.14 Section 97.14 Agriculture... PLANT VARIETY AND PROTECTION The Application § 97.14 Joint applicants. (a) Joint owners shall file a joint application by signing as joint applicants. (b) If an application for certificate is made by...

  7. 14 CFR 27.935 - Shafting joints.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Shafting joints. 27.935 Section 27.935... STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Rotor Drive System § 27.935 Shafting joints. Each universal joint, slip joint, and other shafting joints whose lubrication is necessary for operation must...

  8. 14 CFR 29.935 - Shafting joints.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Shafting joints. 29.935 Section 29.935... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Rotor Drive System § 29.935 Shafting joints. Each universal joint, slip joint, and other shafting joints whose lubrication is necessary for operation...

  9. 20 CFR 410.645 - Joint hearings.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 20 Employees' Benefits 2 2010-04-01 2010-04-01 false Joint hearings. 410.645 Section 410.645..., Finality of Decisions, and Representation of Parties § 410.645 Joint hearings. When two or more hearings... joint hearing, a joint hearing may not be held. Where joint hearings are held, a single record of...

  10. 49 CFR 213.121 - Rail joints.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Rail joints. 213.121 Section 213.121..., DEPARTMENT OF TRANSPORTATION TRACK SAFETY STANDARDS Track Structure § 213.121 Rail joints. (a) Each rail joint, insulated joint, and compromise joint shall be of a structurally sound design and dimensions...

  11. 49 CFR 213.121 - Rail joints.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Rail joints. 213.121 Section 213.121..., DEPARTMENT OF TRANSPORTATION TRACK SAFETY STANDARDS Track Structure § 213.121 Rail joints. (a) Each rail joint, insulated joint, and compromise joint shall be of a structurally sound design and dimensions...

  12. 49 CFR 213.121 - Rail joints.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Rail joints. 213.121 Section 213.121..., DEPARTMENT OF TRANSPORTATION TRACK SAFETY STANDARDS Track Structure § 213.121 Rail joints. (a) Each rail joint, insulated joint, and compromise joint shall be of a structurally sound design and dimensions...

  13. 49 CFR 213.121 - Rail joints.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Rail joints. 213.121 Section 213.121..., DEPARTMENT OF TRANSPORTATION TRACK SAFETY STANDARDS Track Structure § 213.121 Rail joints. (a) Each rail joint, insulated joint, and compromise joint shall be of a structurally sound design and dimensions...

  14. 37 CFR 1.45 - Joint inventors.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 37 Patents, Trademarks, and Copyrights 1 2012-07-01 2012-07-01 false Joint inventors. 1.45 Section... Patent § 1.45 Joint inventors. (a) Joint inventors must apply for a patent jointly and each must make the... joint application under 35 U.S.C. 116. If multiple inventors are named in a provisional...

  15. 37 CFR 1.45 - Joint inventors.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 37 Patents, Trademarks, and Copyrights 1 2011-07-01 2011-07-01 false Joint inventors. 1.45 Section... Patent § 1.45 Joint inventors. (a) Joint inventors must apply for a patent jointly and each must make the... joint application under 35 U.S.C. 116. If multiple inventors are named in a provisional...

  16. 7 CFR 97.14 - Joint applicants.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 3 2011-01-01 2011-01-01 false Joint applicants. 97.14 Section 97.14 Agriculture... PLANT VARIETY AND PROTECTION The Application § 97.14 Joint applicants. (a) Joint owners shall file a joint application by signing as joint applicants. (b) If an application for certificate is made by...

  17. 14 CFR 27.935 - Shafting joints.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Shafting joints. 27.935 Section 27.935... STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Rotor Drive System § 27.935 Shafting joints. Each universal joint, slip joint, and other shafting joints whose lubrication is necessary for operation must...

  18. 14 CFR 29.935 - Shafting joints.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Shafting joints. 29.935 Section 29.935... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Rotor Drive System § 29.935 Shafting joints. Each universal joint, slip joint, and other shafting joints whose lubrication is necessary for operation...

  19. 14 CFR 29.935 - Shafting joints.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Shafting joints. 29.935 Section 29.935... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Rotor Drive System § 29.935 Shafting joints. Each universal joint, slip joint, and other shafting joints whose lubrication is necessary for operation...

  20. 7 CFR 97.14 - Joint applicants.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Joint applicants. 97.14 Section 97.14 Agriculture... PLANT VARIETY AND PROTECTION The Application § 97.14 Joint applicants. (a) Joint owners shall file a joint application by signing as joint applicants. (b) If an application for certificate is made by...

  1. 20 CFR 410.645 - Joint hearings.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 20 Employees' Benefits 2 2011-04-01 2011-04-01 false Joint hearings. 410.645 Section 410.645..., Finality of Decisions, and Representation of Parties § 410.645 Joint hearings. When two or more hearings... joint hearing, a joint hearing may not be held. Where joint hearings are held, a single record of...

  2. 49 CFR 213.121 - Rail joints.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Rail joints. 213.121 Section 213.121..., DEPARTMENT OF TRANSPORTATION TRACK SAFETY STANDARDS Track Structure § 213.121 Rail joints. (a) Each rail joint, insulated joint, and compromise joint shall be of a structurally sound design and dimensions...

  3. 7 CFR 97.14 - Joint applicants.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 3 2013-01-01 2013-01-01 false Joint applicants. 97.14 Section 97.14 Agriculture... PLANT VARIETY AND PROTECTION The Application § 97.14 Joint applicants. (a) Joint owners shall file a joint application by signing as joint applicants. (b) If an application for certificate is made by...

  4. 14 CFR 29.935 - Shafting joints.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Shafting joints. 29.935 Section 29.935... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Rotor Drive System § 29.935 Shafting joints. Each universal joint, slip joint, and other shafting joints whose lubrication is necessary for operation...

  5. 37 CFR 1.45 - Joint inventors.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 37 Patents, Trademarks, and Copyrights 1 2010-07-01 2010-07-01 false Joint inventors. 1.45 Section... Patent § 1.45 Joint inventors. (a) Joint inventors must apply for a patent jointly and each must make the... patent for an invention invented by them jointly, except as provided in § 1.47. (b) Inventors may...

  6. Method of forming a joint

    DOEpatents

    Butt, Darryl Paul; Cutler, Raymond Ashton; Rynders, Steven Walton; Carolan, Michael Francis

    2006-08-22

    A method of joining at least two sintered bodies to form a composite structure, including providing a first multicomponent metallic oxide having a perovskitic or fluorite crystal structure; providing a second sintered body including a second multicomponent metallic oxide having a crystal structure of the same type as the first; and providing at an interface a joint material containing at least one metal oxide containing at least one metal identically contained in at least one of the first and second multicomponent metallic oxides. The joint material is free of cations of Si, Ge, Sn, Pb, P and Te and has a melting point below the sintering temperatures of both sintered bodies. The joint material is heated to a temperature above the melting point of the metal oxide(s) and below the sintering temperatures of the sintered bodies to form the joint. Structures containing such joints are also disclosed.

  7. General joint hypermobility and temporomandibular joint derangement in adolescents.

    PubMed Central

    Westling, L; Mattiasson, A

    1992-01-01

    Joint mobility was assessed in each member of an epidemiological sample of 96 girls and 97 boys, 17 years old, and graded by means of the hypermobility score of Beighton et al. Twenty two per cent of the girls and 3% of the boys could perform five or more of the nine manoeuvres. The prevalence of symptoms and signs of internal derangement in the temporomandibular joint was higher in adolescents with hypermobility of joints (score greater than or equal to 5/9). In subjects with a high mobility score oral parafunctions (overuse) correlated more strongly with several signs and symptoms of craniomandibular disorder than in those with a low score. PMID:1540046

  8. Acromioclavicular joint cyst formation.

    PubMed

    Hiller, Andrew D; Miller, Joshua D; Zeller, John L

    2010-03-01

    Acromioclavicular joint (ACJ) cysts are an uncommon and unusual sequela associated with shoulder pathophysiology. The majority of literature on ACJ cysts consists of individual case reports with no definitive literature review currently available. In addition to a comprehensive literature review, four clinical cases are presented in this report. First described by Craig (1984), a total of 41 cases have been previously reported in the literature. Of these cases, five occurred with the rotator cuff musculature intact. The remaining 36 cases of ACJ cysts occurred in patients with a complete tear/avulsion of the rotator cuff. Previous attempts at compiling a complete record of all reported cases have combined several distinct conditions into a single category. This article presents two distinct etiologies for the pathogenesis of ACJ cyst formation. In the presence of an intact rotator cuff, a Type 1 cyst can form superficially and be limited to the ACJ. Following a massive or traumatic tear of the rotator cuff, mechanical instability of the humeral head can cause a deterioration of the inferior acromioclavicular capsule (cuff tear arthropathy) and an overproduction of synovial fluid. Overtime, a "geyser" of fluid can form between the glenohumeral and the ACJ, forming a Type 2 cyst. This differentiation and categorization is essential for appropriate classification and treatment.

  9. Acromioclavicular joint cyst formation.

    PubMed

    Hiller, Andrew D; Miller, Joshua D; Zeller, John L

    2010-03-01

    Acromioclavicular joint (ACJ) cysts are an uncommon and unusual sequela associated with shoulder pathophysiology. The majority of literature on ACJ cysts consists of individual case reports with no definitive literature review currently available. In addition to a comprehensive literature review, four clinical cases are presented in this report. First described by Craig (1984), a total of 41 cases have been previously reported in the literature. Of these cases, five occurred with the rotator cuff musculature intact. The remaining 36 cases of ACJ cysts occurred in patients with a complete tear/avulsion of the rotator cuff. Previous attempts at compiling a complete record of all reported cases have combined several distinct conditions into a single category. This article presents two distinct etiologies for the pathogenesis of ACJ cyst formation. In the presence of an intact rotator cuff, a Type 1 cyst can form superficially and be limited to the ACJ. Following a massive or traumatic tear of the rotator cuff, mechanical instability of the humeral head can cause a deterioration of the inferior acromioclavicular capsule (cuff tear arthropathy) and an overproduction of synovial fluid. Overtime, a "geyser" of fluid can form between the glenohumeral and the ACJ, forming a Type 2 cyst. This differentiation and categorization is essential for appropriate classification and treatment. PMID:20069645

  10. Joint services electronics program

    NASA Astrophysics Data System (ADS)

    Peters, Leon, Jr.

    1992-11-01

    The report represents the fifteenth annual summary of The Ohio State University Joint Services Electronics Program (JSEP). The transfer of the compact range identification technology initiated under JSEP support for time domain studies continues to make large advances. We are also assisting Rockwell (Tulsa) to update their RCS facilities. This work is on a subcontract to the ESL from the Air Force. This has lead to involvement in the study of Ultra Wide Band radar systems. The research activities devoted to the Generalized Ray and Gaussian Beams continues. Our JSEP research continues to be expanded by external funding. This program is being expanded by use of such funds which are more focussed on the requirements of the sponsors which includes both the Air Force and the Navy. Our JSEP research continues to focus on electromagnetic related topics. There are four major electromagnetics areas that were pursued in the past year. The Diffraction Studies Work Unit has initiated research on a time domain version of the Uniform Theory of Diffraction. A second topic under the Diffraction Studies Work Unit involves further extensions of the generalized resistive boundary condition and the generalized impedance boundary condition. These have been applied to scattering from a chiral slab. A third topic of interest is the diffraction from a corner. A fourth task involves the reflection/diffraction of a Gaussian beam. This represents an approach to replace the usual ray optics solution for very complex geometries where the versatile ray optics solution becomes cumbersome.

  11. Arthritis: joints inflamed.

    PubMed

    Casey, Georgina

    2015-06-01

    ARTHRITIS IS a generic term for inflammatory joint disease. There are various forms of arthritis, including osteoarthritis, rheumatoid arthritis and spondyloarthritis. Arthritis can be a chronic debilitating condition or a transient effect of bacterial or viral infections. As a chronic condition, arthritis can cause loss of quality of life, disability and, with rheumatoid disease, early death. The economic burden of arthritis, in terms of management and loss of productivity due to disability, is high and set to increase with the ageing population. Recent advances in our understanding of the causes and progression of a number of forms of arthritis have raised hopes of better management and possible remission. Pharmacotherapy has moved from symptom management to addressing underlying disease processes. However, therapies that prevent or cure arthritis remain elusive. Current care for people with arthritis relies on a multidisciplinary approach and substantial pharmacological intervention. Nurses have a key role to play in guiding patients through treatment, ensuring they receive optimal therapy to reduce the impact of arthritis and its management on their lives.

  12. Qualification of improved joint heaters

    NASA Technical Reports Server (NTRS)

    Cook, M.

    1989-01-01

    Qualification testing of the Redesigned Solid Rocket Motor improved igniter-to-case joint and field joint heaters was conducted on the fired TEM-04 static test motor and was completed on 7 Sep. 1989. The purpose of the test was to certify the installation and performance of the improved joint heaters for use on flight motors. The changes incorporated in the improved heaters improve durability and should reduce handling damage. The igniter-to-case joint and field joint primary heater circuits were subjected to five 20-hr ON cycles. The heater redundant circuits were then subjected to one 20-hr ON cycle. Voltage, current, and temperature set point values were maintained within the specified limits for both heaters during each ON cycle. When testing was complete, both heaters were removed and inspected. No discolorations or any other anomalies were found on either of the heaters. Based on the successful completion of this test, it is recommended that the improved igniter-to-case joint and field joint heaters be used on future flight motors.

  13. Common Bolted Joint Analysis Tool

    NASA Technical Reports Server (NTRS)

    Imtiaz, Kauser

    2011-01-01

    Common Bolted Joint Analysis Tool (comBAT) is an Excel/VB-based bolted joint analysis/optimization program that lays out a systematic foundation for an inexperienced or seasoned analyst to determine fastener size, material, and assembly torque for a given design. Analysts are able to perform numerous what-if scenarios within minutes to arrive at an optimal solution. The program evaluates input design parameters, performs joint assembly checks, and steps through numerous calculations to arrive at several key margins of safety for each member in a joint. It also checks for joint gapping, provides fatigue calculations, and generates joint diagrams for a visual reference. Optimum fastener size and material, as well as correct torque, can then be provided. Analysis methodology, equations, and guidelines are provided throughout the solution sequence so that this program does not become a "black box:" for the analyst. There are built-in databases that reduce the legwork required by the analyst. Each step is clearly identified and results are provided in number format, as well as color-coded spelled-out words to draw user attention. The three key features of the software are robust technical content, innovative and user friendly I/O, and a large database. The program addresses every aspect of bolted joint analysis and proves to be an instructional tool at the same time. It saves analysis time, has intelligent messaging features, and catches operator errors in real time.

  14. Compliant Prosthetic Or Robotic Joint

    NASA Technical Reports Server (NTRS)

    Kerley, James J.; Eklund, Wayne D.

    1989-01-01

    Rotation partly free and partly restrained by resilience and damping. Joint includes U-shaped x- and y-axis frames joined by cables that cross in at center piece. The y-axis frame rotates about y-axis on roller bearing within predetermined angular range. The y-axis frame rotates slightly farther when arm strikes stop, because cables can twist. This mimics compliant resistance of knee joint reaching limit of its forward or backward motion. Used in prosthetic device to replace diseased or damage human joint, or in robot linkage to limit movement and cushion overloads.

  15. Joint ventures in health care.

    PubMed

    Pelfrey, S; Theisen, B A

    1989-04-01

    To remain competitive, many not-for-profit hospitals have turned to joint ventures with for-profit and other not-for-profit entities. The authors examine the organizational structures that are used most often to form joint ventures (contractual agreements, subsidiary corporations, partnerships, and not-for-profit title-holding corporations), as well as the advantages and disadvantages associated with each form. Nurse executives must be aware of the opportunities that joint ventures provide their institutions. These arrangements can help improve and expand services and profitability.

  16. Osteochondral Lesions of Major Joints

    PubMed Central

    Durur-Subasi, Irmak; Durur-Karakaya, Afak; Yildirim, Omer Selim

    2015-01-01

    This paper provides information about osteochondral lesions (OCL) and example cases of OCL occurring in major joints, some of which are rarely seen. This simple tutorial is presented in question and answer format. PMID:26180500

  17. Campus/Industry Joint Ventures.

    ERIC Educational Resources Information Center

    McDonald, Eugene J.

    1985-01-01

    Opportunities for joint economic ventures of colleges and industry are discussed, and a variety of ventures undertaken by Duke University are outlined, including a health club, hotel, and office building. Tax and financing considerations are noted. (MSE)

  18. Joint probabilities and quantum cognition

    SciTech Connect

    Acacio de Barros, J.

    2012-12-18

    In this paper we discuss the existence of joint probability distributions for quantumlike response computations in the brain. We do so by focusing on a contextual neural-oscillator model shown to reproduce the main features of behavioral stimulus-response theory. We then exhibit a simple example of contextual random variables not having a joint probability distribution, and describe how such variables can be obtained from neural oscillators, but not from a quantum observable algebra.

  19. Rothia prosthetic knee joint infection.

    PubMed

    Trivedi, Manish N; Malhotra, Prashant

    2015-08-01

    Rothia species - Gram-positive pleomorphic bacteria that are part of the normal oral and respiratory flora - are commonly associated with dental cavities and periodontal disease although systemic infections have been described. We describe a 53-year-old female with rheumatoid arthritis complicated by prosthetic knee joint infection due to Rothia species, which was successfully treated by surgical removal of prosthesis and prolonged antimicrobial therapy. The issue of antibiotic prophylaxis before dental procedures among patients with prosthetic joint replacements is discussed.

  20. Pyrothermal treatment of welded joints

    SciTech Connect

    Serikov, S.V.; Idiyatullin, R.S.; Myakushkin, S.N.; Yaufman, V.V.

    1992-03-01

    The results of investigation of the structure and distribution of residual stresses in welded joints in pipes after heat treatment, which includes heating of the surface being treated due to combustion of plates formed from a thermite-type material of pyrotechnic composition, placed around the perimeter of the welded joint, and also an assessment of the level of residual stresses prior to and after pyrotechnic treatment demonstrated the promising nature of the proposed method. 5 refs., 5 figs.

  1. Joint probabilities and quantum cognition

    NASA Astrophysics Data System (ADS)

    de Barros, J. Acacio

    2012-12-01

    In this paper we discuss the existence of joint probability distributions for quantumlike response computations in the brain. We do so by focusing on a contextual neural-oscillator model shown to reproduce the main features of behavioral stimulus-response theory. We then exhibit a simple example of contextual random variables not having a joint probability distribution, and describe how such variables can be obtained from neural oscillators, but not from a quantum observable algebra.

  2. IRS memorandum limits joint ventures.

    PubMed

    Herman, A W

    1992-08-01

    Based on a new memorandum, the Internal Revenue Service (IRS) will be looking at joint hospital/physician activities with greater attention to the nuances of public versus private benefit. As a result, hospitals face greater risk of losing their tax-exempt status in the maze of joint ventures, physician recruitment, and practice acquisition. To be successful, ventures will have to be backed by sound reasoning and thorough documentation.

  3. "Fraud alert": joint venture arrangements.

    PubMed

    Vipperman, R M

    1989-01-01

    The Office of Inspector General of the Department of Health and Human Services recently issued a special "Fraud Alert" identifying those characteristics of joint venture arrangements that it views as indicators of potentially unlawful activity. As discussed in this article, participants in joint ventures should examine their arrangements to see if one or more of the questionable features are present, and, if so, should take steps to eliminate them, to the extent possible.

  4. Sound Transmission at Pipe Joints.

    NASA Astrophysics Data System (ADS)

    Servis, Dimitris C.

    Available from UMI in association with The British Library. A model was developed using beam and plane wave theory to describe the sound transmission at pipe joints. This approach greatly simplifies the modelling of the pipe joint and the solution is presented in a manner which can be applied in both the Frequency and the Time domain, for the solution of acoustic and fluid dynamics problems related to pipe joint transmission. This form of modelling can be extended to describe a wide range of pipe joints and discontinuities and lend itself to the study of piping networks by incorporating its solution in existing models used to describe the performance of large systems. A variety of experimental techniques have been explored and applied for the measurement of the sound transmission at pipe joints. The model predictions were found to be in good agreement with experimental data and form the basis of a simple and effective method for the study of sound transmission at pipe joints.

  5. 12 CFR 347.107 - Joint ventures.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 12 Banks and Banking 5 2013-01-01 2013-01-01 false Joint ventures. 347.107 Section 347.107 Banks... INTERNATIONAL BANKING § 347.107 Joint ventures. (a) Joint ventures. If a bank, directly or indirectly, acquires or holds an equity interest in a foreign organization that is a joint venture, and the bank or...

  6. 47 CFR 76.912 - Joint certification.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Joint certification. 76.912 Section 76.912... CABLE TELEVISION SERVICE Cable Rate Regulation § 76.912 Joint certification. (a) Franchising authorities may apply for joint certification and may engage in joint regulation, including, but not limited...

  7. 49 CFR 234.233 - Rail joints.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Rail joints. 234.233 Section 234.233..., Inspection, and Testing Maintenance Standards § 234.233 Rail joints. Each non-insulated rail joint located... than joint bars and the bonds shall be maintained in such condition to ensure electrical conductivity....

  8. 14 CFR 23.693 - Joints.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Joints. 23.693 Section 23.693 Aeronautics... Systems § 23.693 Joints. Control system joints (in push-pull systems) that are subject to angular motion... factor may be reduced to 2.0 for joints in cable control systems. For ball or roller bearings,...

  9. 30 CFR 36.24 - Engine joints.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Engine joints. 36.24 Section 36.24 Mineral... Construction and Design Requirements § 36.24 Engine joints. (a) Cylinder head. The joint between the cylinder.... This joint shall provide an adequate flame barrier with the gasket in place. (b) Valve guides....

  10. 32 CFR 536.54 - Joint tortfeasors.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 32 National Defense 3 2013-07-01 2013-07-01 false Joint tortfeasors. 536.54 Section 536.54... AGAINST THE UNITED STATES Investigation and Processing of Claims § 536.54 Joint tortfeasors. When joint... United States rather than pay the claim in full and then bring suit against the joint tortfeasor...

  11. 14 CFR 23.693 - Joints.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Joints. 23.693 Section 23.693 Aeronautics... Systems § 23.693 Joints. Control system joints (in push-pull systems) that are subject to angular motion... factor may be reduced to 2.0 for joints in cable control systems. For ball or roller bearings,...

  12. 49 CFR 234.233 - Rail joints.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Rail joints. 234.233 Section 234.233... joints. Each non-insulated rail joint located within the limits of a highway-rail grade crossing train detection circuit shall be bonded by means other than joint bars and the bonds shall be maintained in...

  13. 14 CFR 23.693 - Joints.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Joints. 23.693 Section 23.693 Aeronautics... Systems § 23.693 Joints. Control system joints (in push-pull systems) that are subject to angular motion... factor may be reduced to 2.0 for joints in cable control systems. For ball or roller bearings,...

  14. 42 CFR 422.1040 - Joint hearings.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 3 2010-10-01 2010-10-01 false Joint hearings. 422.1040 Section 422.1040 Public...) MEDICARE PROGRAM MEDICARE ADVANTAGE PROGRAM Appeal procedures for Civil Money Penalties § 422.1040 Joint... conference or hearing and conduct all proceedings jointly. If joint hearings are held, a single record of...

  15. 47 CFR 76.912 - Joint certification.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 4 2012-10-01 2012-10-01 false Joint certification. 76.912 Section 76.912... CABLE TELEVISION SERVICE Cable Rate Regulation § 76.912 Joint certification. (a) Franchising authorities may apply for joint certification and may engage in joint regulation, including, but not limited...

  16. 47 CFR 76.912 - Joint certification.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 4 2013-10-01 2013-10-01 false Joint certification. 76.912 Section 76.912... CABLE TELEVISION SERVICE Cable Rate Regulation § 76.912 Joint certification. (a) Franchising authorities may apply for joint certification and may engage in joint regulation, including, but not limited...

  17. 42 CFR 422.1040 - Joint hearings.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 3 2011-10-01 2011-10-01 false Joint hearings. 422.1040 Section 422.1040 Public...) MEDICARE PROGRAM MEDICARE ADVANTAGE PROGRAM Appeal procedures for Civil Money Penalties § 422.1040 Joint... conference or hearing and conduct all proceedings jointly. If joint hearings are held, a single record of...

  18. 12 CFR 347.107 - Joint ventures.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 12 Banks and Banking 5 2014-01-01 2014-01-01 false Joint ventures. 347.107 Section 347.107 Banks... INTERNATIONAL BANKING § 347.107 Joint ventures. (a) Joint ventures. If a bank, directly or indirectly, acquires or holds an equity interest in a foreign organization that is a joint venture, and the bank or...

  19. 49 CFR 234.233 - Rail joints.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Rail joints. 234.233 Section 234.233... joints. Each non-insulated rail joint located within the limits of a highway-rail grade crossing train detection circuit shall be bonded by means other than joint bars and the bonds shall be maintained in...

  20. 32 CFR 536.54 - Joint tortfeasors.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 32 National Defense 3 2011-07-01 2009-07-01 true Joint tortfeasors. 536.54 Section 536.54 National... UNITED STATES Investigation and Processing of Claims § 536.54 Joint tortfeasors. When joint tortfeasors... United States rather than pay the claim in full and then bring suit against the joint tortfeasor...

  1. 14 CFR 23.693 - Joints.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Joints. 23.693 Section 23.693 Aeronautics... Systems § 23.693 Joints. Control system joints (in push-pull systems) that are subject to angular motion... factor may be reduced to 2.0 for joints in cable control systems. For ball or roller bearings,...

  2. 49 CFR 234.233 - Rail joints.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Rail joints. 234.233 Section 234.233..., Inspection, and Testing Maintenance Standards § 234.233 Rail joints. Each non-insulated rail joint located... than joint bars and the bonds shall be maintained in such condition to ensure electrical conductivity....

  3. 32 CFR 536.54 - Joint tortfeasors.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 32 National Defense 3 2014-07-01 2014-07-01 false Joint tortfeasors. 536.54 Section 536.54... AGAINST THE UNITED STATES Investigation and Processing of Claims § 536.54 Joint tortfeasors. When joint... United States rather than pay the claim in full and then bring suit against the joint tortfeasor...

  4. 42 CFR 423.1040 - Joint hearings.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 3 2010-10-01 2010-10-01 false Joint hearings. 423.1040 Section 423.1040 Public... § 423.1040 Joint hearings. When two or more affected parties have requested hearings and the same or... the prehearing conference or hearing and conduct all proceedings jointly. If joint hearings are...

  5. 47 CFR 76.912 - Joint certification.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 4 2011-10-01 2011-10-01 false Joint certification. 76.912 Section 76.912... CABLE TELEVISION SERVICE Cable Rate Regulation § 76.912 Joint certification. (a) Franchising authorities may apply for joint certification and may engage in joint regulation, including, but not limited...

  6. 32 CFR 536.54 - Joint tortfeasors.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 3 2010-07-01 2010-07-01 true Joint tortfeasors. 536.54 Section 536.54 National... UNITED STATES Investigation and Processing of Claims § 536.54 Joint tortfeasors. When joint tortfeasors... United States rather than pay the claim in full and then bring suit against the joint tortfeasor...

  7. 42 CFR 423.1040 - Joint hearings.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 3 2011-10-01 2011-10-01 false Joint hearings. 423.1040 Section 423.1040 Public... § 423.1040 Joint hearings. When two or more affected parties have requested hearings and the same or... the prehearing conference or hearing and conduct all proceedings jointly. If joint hearings are...

  8. 42 CFR 422.1040 - Joint hearings.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 3 2013-10-01 2013-10-01 false Joint hearings. 422.1040 Section 422.1040 Public....1040 Joint hearings. When two or more affected parties have requested hearings and the same or... the prehearing conference or hearing and conduct all proceedings jointly. If joint hearings are...

  9. 49 CFR 234.233 - Rail joints.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Rail joints. 234.233 Section 234.233... joints. Each non-insulated rail joint located within the limits of a highway-rail grade crossing train detection circuit shall be bonded by means other than joint bars and the bonds shall be maintained in...

  10. 42 CFR 422.1040 - Joint hearings.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 3 2014-10-01 2014-10-01 false Joint hearings. 422.1040 Section 422.1040 Public....1040 Joint hearings. When two or more affected parties have requested hearings and the same or... the prehearing conference or hearing and conduct all proceedings jointly. If joint hearings are...

  11. 12 CFR 347.107 - Joint ventures.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 12 Banks and Banking 5 2012-01-01 2012-01-01 false Joint ventures. 347.107 Section 347.107 Banks... INTERNATIONAL BANKING § 347.107 Joint ventures. (a) Joint ventures. If a bank, directly or indirectly, acquires or holds an equity interest in a foreign organization that is a joint venture, and the bank or...

  12. 21 CFR 26.73 - Joint Committee.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 1 2011-04-01 2011-04-01 false Joint Committee. 26.73 Section 26.73 Food and...Frameworkâ Provisions § 26.73 Joint Committee. (a) A Joint Committee consisting of representatives of the United States and the European Community (EC) will be established. The Joint Committee shall...

  13. 30 CFR 36.24 - Engine joints.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Engine joints. 36.24 Section 36.24 Mineral... Construction and Design Requirements § 36.24 Engine joints. (a) Cylinder head. The joint between the cylinder.... This joint shall provide an adequate flame barrier with the gasket in place. (b) Valve guides....

  14. 30 CFR 36.24 - Engine joints.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Engine joints. 36.24 Section 36.24 Mineral... Construction and Design Requirements § 36.24 Engine joints. (a) Cylinder head. The joint between the cylinder.... This joint shall provide an adequate flame barrier with the gasket in place. (b) Valve guides....

  15. 42 CFR 422.1040 - Joint hearings.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 3 2012-10-01 2012-10-01 false Joint hearings. 422.1040 Section 422.1040 Public....1040 Joint hearings. When two or more affected parties have requested hearings and the same or... the prehearing conference or hearing and conduct all proceedings jointly. If joint hearings are...

  16. 32 CFR 536.54 - Joint tortfeasors.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 32 National Defense 3 2012-07-01 2009-07-01 true Joint tortfeasors. 536.54 Section 536.54 National... UNITED STATES Investigation and Processing of Claims § 536.54 Joint tortfeasors. When joint tortfeasors... United States rather than pay the claim in full and then bring suit against the joint tortfeasor...

  17. 30 CFR 36.24 - Engine joints.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Engine joints. 36.24 Section 36.24 Mineral... Construction and Design Requirements § 36.24 Engine joints. (a) Cylinder head. The joint between the cylinder.... This joint shall provide an adequate flame barrier with the gasket in place. (b) Valve guides....

  18. 30 CFR 36.24 - Engine joints.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Engine joints. 36.24 Section 36.24 Mineral... Construction and Design Requirements § 36.24 Engine joints. (a) Cylinder head. The joint between the cylinder.... This joint shall provide an adequate flame barrier with the gasket in place. (b) Valve guides....

  19. 21 CFR 26.73 - Joint Committee.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 1 2014-04-01 2014-04-01 false Joint Committee. 26.73 Section 26.73 Food and...Frameworkâ Provisions § 26.73 Joint Committee. (a) A Joint Committee consisting of representatives of the United States and the European Community (EC) will be established. The Joint Committee shall...

  20. 47 CFR 76.912 - Joint certification.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 4 2014-10-01 2014-10-01 false Joint certification. 76.912 Section 76.912... CABLE TELEVISION SERVICE Cable Rate Regulation § 76.912 Joint certification. (a) Franchising authorities may apply for joint certification and may engage in joint regulation, including, but not limited...

  1. 12 CFR 347.107 - Joint ventures.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 12 Banks and Banking 4 2011-01-01 2011-01-01 false Joint ventures. 347.107 Section 347.107 Banks... INTERNATIONAL BANKING § 347.107 Joint ventures. (a) Joint ventures. If a bank, directly or indirectly, acquires or holds an equity interest in a foreign organization that is a joint venture, and the bank or...

  2. 38 CFR 4.45 - The joints.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2010-07-01 2010-07-01 false The joints. 4.45 Section... DISABILITIES Disability Ratings The Musculoskeletal System § 4.45 The joints. As regards the joints the factors... (from flail joint, resections, nonunion of fracture, relaxation of ligaments, etc.). (c)...

  3. 38 CFR 4.45 - The joints.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2014-07-01 2014-07-01 false The joints. 4.45 Section... DISABILITIES Disability Ratings The Musculoskeletal System § 4.45 The joints. As regards the joints the factors... (from flail joint, resections, nonunion of fracture, relaxation of ligaments, etc.). (c)...

  4. 38 CFR 4.45 - The joints.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2013-07-01 2013-07-01 false The joints. 4.45 Section... DISABILITIES Disability Ratings The Musculoskeletal System § 4.45 The joints. As regards the joints the factors... (from flail joint, resections, nonunion of fracture, relaxation of ligaments, etc.). (c)...

  5. 38 CFR 4.45 - The joints.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2012-07-01 2012-07-01 false The joints. 4.45 Section... DISABILITIES Disability Ratings The Musculoskeletal System § 4.45 The joints. As regards the joints the factors... (from flail joint, resections, nonunion of fracture, relaxation of ligaments, etc.). (c)...

  6. 38 CFR 4.45 - The joints.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2011-07-01 2011-07-01 false The joints. 4.45 Section... DISABILITIES Disability Ratings The Musculoskeletal System § 4.45 The joints. As regards the joints the factors... (from flail joint, resections, nonunion of fracture, relaxation of ligaments, etc.). (c)...

  7. Condylar hyperplasia following unilateral temporomandibular joint replacement.

    PubMed

    Machon, V; Levorova, J; Hirjak, D; Foltan, R

    2015-06-01

    Total joint replacement of the temporomandibular joint (TJR) can be associated with intraoperative and postoperative complications. We report herein the occurrence of a postoperative open bite malocclusion, the result of condylar hyperplasia affecting the non-operated joint at 1 year after unilateral total joint replacement. PMID:25662429

  8. Management of acromioclavicular joint injuries.

    PubMed

    Li, Xinning; Ma, Richard; Bedi, Asheesh; Dines, David M; Altchek, David W; Dines, Joshua S

    2014-01-01

    Acromioclavicular joint injuries are among the most common shoulder girdle injuries in athletes and most commonly result from a direct force to the acromion with the arm in an adducted position. Acromioclavicular joint injuries often present with associated injuries to the glenohumeral joint, including an increased incidence of superior labrum anterior posterior (SLAP) tears that may warrant further evaluation and treatment. Anteroposterior stability of the acromioclavicular joint is conferred by the capsule and acromioclavicular ligaments, of which the posterior and superior ligaments are the strongest. Superior-inferior stability is maintained by the coracoclavicular (conoid and trapezoid) ligaments. Type-I or type-II acromioclavicular joint injuries have been treated with sling immobilization, early shoulder motion, and physical therapy, with favorable outcomes. Return to activity can occur when normal shoulder motion and strength are obtained and the shoulder is asymptomatic as compared with the contralateral normal extremity. The management of type-III injuries remains controversial and is individualized. While a return to the previous level of functional activity with nonsurgical treatment has been documented in a number of case series, surgical reduction and coracoclavicular ligament reconstruction has been associated with a favorable outcome and can be considered in patients who place high functional demands on their shoulders or in athletes who participate in overhead sports. Surgical management is indicated for high-grade (≥type IV) acromioclavicular joint injuries to achieve anatomic reduction of the acromioclavicular joint, reconstruction of the coracoclavicular ligaments, and repair of the deltotrapezial fascia. Outcomes after surgical reconstruction of the coracoclavicular ligaments have been satisfactory with regard to achieving pain relief and return to functional activities, but further improvements in the biomechanical strength of these

  9. Strength evaluation of socket joints

    NASA Technical Reports Server (NTRS)

    Rash, Larry C.

    1994-01-01

    This report documents the development of a set of equations that can be used to provide a relatively simple solution for identifying the strength of socket joints and for most cases avoid the need of more lengthy analyses. The analytical approach was verified by comparison of the contact load distributions to results obtained from a finite element analysis. The contacting surfaces for the specific joint in this analysis are in the shape of frustrums of a cone and are representative of the tapered surfaces in the socket-type joints used to join segments of model support systems for wind tunnels. The results are in the form of equations that can be used to determine the contact loads and stresses in the joint from the given geometry and externally applied loads. Equations were determined to define the bending moments and stresses along the length of the joints based on strength and materials principles. The results have also been programmed for a personal computer and a copy of the program is included.

  10. [Injuries of the acromioclavicular joint].

    PubMed

    Meeder, P J; Dannöhl, C

    1988-07-01

    The injuries of the acromio-clavicular joint require a differentiated diagnosis and treatment. The classification of the acromio-clavicular dislocations from grade I to grade III according to Tossy is proved. The diagnosis of a complete acromio-clavicular dislocation (Tossy III) is an indication for a surgical repair. Many and different methods are reported in the literature. 178 patients with a fresh acromio-clavicular dislocation (Typ Tossy II and III) were treated at the BG-Unfallklinik Tübingen from 1970 to 1987 by suturing the ligaments, inserting pins across the joint and tension wire bending. In old cases with Tossy III dislocation of the acromio-clavicular joint an oblique osteotomy combined with the reduction of the clavicle is recommended as a method of choice. The results of these procedures and there possible intra- and postoperative complications are reported. The incision along the clavicle quite often gives scar problems. Therefore the advantages of an arched incision across the acromio-clavicular joint is pointed out. Because of there biomechanical relationship fractures in the lateral third of the clavicle are similar to dislocations of the acromio-clavicular joint. The classification of these fractures according to Jäger, Buschle and Breitner allows a differentiated management of these lesions.

  11. An analysis of a joint shear model for jointed media with orthogonal joint sets; Yucca Mountain Site Characterization Project

    SciTech Connect

    Koteras, J.R.

    1991-10-01

    This report describes a joint shear model used in conjunction with a computational model for jointed media with orthogonal joint sets. The joint shear model allows nonlinear behavior for both joint sets. Because nonlinear behavior is allowed for both joint sets, a great many cases must be considered to fully describe the joint shear behavior of the jointed medium. An extensive set of equations is required to describe the joint shear stress and slip displacements that can occur for all the various cases. This report examines possible methods for simplifying this set of equations so that the model can be implemented efficiently form a computational standpoint. The shear model must be examined carefully to obtain a computationally efficient implementation that does not lead to numerical problems. The application to fractures in rock is discussed. 5 refs., 4 figs.

  12. Denervation of the wrist joint.

    PubMed

    Buck-Gramcko, D

    1977-01-01

    A collective review was made of the results of denervation of the wrist joint for painful restrictiorn of motion done in 313 patients and follow-up studies on 195 (average 4.1 years, ranging from 9 months to 14 years). Complete denervation was done in only 30, partial denervation in the others being done after testing with local anesthetic blocks. Sixty-nine of the patients retained a moble wrist without pain or with slight pain with heavy work. No evidence of Charcot-like joints was seen. Poorest results followed when the operation was done for sequelae of intra-articular fracture of the radius, fracture dislocations, unstable ligamentous support, joint surface destruction, or for those required to do heavy manual labor. Arthrodesis was done secondarily in nine patients. PMID:839055

  13. Joint attention and language evolution

    NASA Astrophysics Data System (ADS)

    Kwisthout, Johan; Vogt, Paul; Haselager, Pim; Dijkstra, Ton

    2008-06-01

    This study investigates how more advanced joint attentional mechanisms, rather than only shared attention between two agents and an object, can be implemented and how they influence the results of language games played by these agents. We present computer simulations with language games showing that adding constructs that mimic the three stages of joint attention identified in children's early development (checking attention, following attention, and directing attention) substantially increase the performance of agents in these language games. In particular, the rates of improved performance for the individual attentional mechanisms have the same ordering as that of the emergence of these mechanisms in infants' development. These results suggest that language evolution and joint attentional mechanisms have developed in a co-evolutionary way, and that the evolutionary emergence of the individual attentional mechanisms is ordered just like their developmental emergence.

  14. Uncertainty of knee joint muscle activity during knee joint torque exertion: the significance of controlling adjacent joint torque.

    PubMed

    Nozaki, Daichi; Nakazawa, Kimitaka; Akai, Masami

    2005-09-01

    In the single-joint torque exertion task, which has been widely used to control muscle activity, only the relevant joint torque is specified. However, the neglect of the neighboring joint could make the procedure unreliable, considering our previous result that even monoarticular muscle activity level is indefinite without specifying the adjacent joint torque. Here we examined the amount of hip joint torque generated with knee joint torque and its influence on the activity of the knee joint muscles. Twelve healthy subjects were requested to exert various levels of isometric knee joint torque. The knee and hip joint torques were obtained by using a custom-made device. Because no information about hip joint torque was provided to the subjects, the hip joint torque measured here was a secondary one associated with the task. The amount of hip joint torque varied among subjects, indicating that they adopted various strategies to achieve the task. In some subjects, there was a considerable internal variability in the hip joint torque. Such variability was not negligible, because the knee joint muscle activity level with respect to the knee joint torque, as quantified by surface electromyography (EMG), changed significantly when the subjects were requested to change the strategy. This change occurred in a very systematic manner: in the case of the knee extension, as the hip flexion torque was larger, the activity of mono- and biarticular knee extensors decreased and increased, respectively. These results indicate that the conventional single knee joint torque exertion has the drawback that the intersubject and/or intertrial variability is inevitable in the relative contribution among mono- and biarticular muscles because of the uncertainty of the hip joint torque. We discuss that the viewpoint that both joint torques need to be considered will bring insights into various controversial problems such as the shape of the EMG-force relationship, neural factors that help

  15. Using joint interactions to estimate paleostress ratios

    NASA Astrophysics Data System (ADS)

    Dyer, R.

    Because they grow perpendicular to a minimum principal stress ( σ3), joints are paleostress markers. Younger joints may show a systematic change in orientation as they approach older, throughgoing, joints. This change in orientation reflects a change in the stress field in which the younger joint set is growing. Analytical solutions for the stress field around a single joint subject to a combination of opening (Mode I) and anti-plane shear (Mode III) loadings are given. The sense of rotation and change in magnitude of principal stresses near an existing joint are functions of the orientation and ratio of magnitudes of the far-field stresses and the coefficient of friction across the joint. Assuming that a later, non-parallel joint nucleates distant from, and grows toward, the throughgoing joint, the stress field in which it is growing will be systematically rotated and changed by the presence of the throughgoing joint. The effect of interaction between the older and younger joints is ignored in the analysis. The systematic change in orientation of the later joint reflects the change in principal stresses near the throughgoing joint, and can be used to place approximate limits on the ratio of the far-field horizontal stresses. Zoned joints are individual, subparallel en échelon joints which are confined to a narrow zone, separated from adjacent zones by a characteristic distance, and confined to a single lithologic interval. A joint zone can be modeled as a single, infinitely long joint with a characteristic height. Comparison of analytic stress field solutions with field examples of interacting zoned joints in Arches National Park, Utah, suggest that a curving-parallel geometry of younger joints is indicative of a stress field in which -3 < σ 2∞/σ 3∞ < - {1}/{3}. A curving-perpendicular geometry of younger zones is compatible with principal stress ratios of - {1}/{3} < σ 2∞/σ 3∞ < 1 .

  16. [Divorce and joint physical custody].

    PubMed

    Golse, B

    2014-04-01

    This work first recalls the definition of joint physical custody, as well as the current legal procedure for obtaining it, its practical implementation, the financial implications for parents, and finally some statistics. Some psychological and psychopathological reflections on the impact of divorce on children are then presented before considering the question of joint physically custody with regard to attachment theory and depending on the age of the child (a great caution seems to be required before three years). The article concludes with a brief discussion of parental alienation syndrome. PMID:24630624

  17. Solder Joint Health Monitoring Testbed

    NASA Technical Reports Server (NTRS)

    Delaney, Michael M.; Flynn, James G.; Browder, Mark E.

    2009-01-01

    A method of monitoring the health of selected solder joints, called SJ-BIST, has been developed by Ridgetop Group Inc. under a Small Business Innovative Research (SBIR) contract. The primary goal of this research program is to test and validate this method in a flight environment using realistically seeded faults in selected solder joints. An additional objective is to gather environmental data for future development of physics-based and data-driven prognostics algorithms. A test board is being designed using a Xilinx FPGA. These boards will be tested both in flight and on the ground using a shaker table and an altitude chamber.

  18. [Divorce and joint physical custody].

    PubMed

    Golse, B

    2014-04-01

    This work first recalls the definition of joint physical custody, as well as the current legal procedure for obtaining it, its practical implementation, the financial implications for parents, and finally some statistics. Some psychological and psychopathological reflections on the impact of divorce on children are then presented before considering the question of joint physically custody with regard to attachment theory and depending on the age of the child (a great caution seems to be required before three years). The article concludes with a brief discussion of parental alienation syndrome.

  19. [Prevention of periprosthetic joint infections].

    PubMed

    Harrasser, Norbert; Harnoss, Tobias

    2012-03-01

    High numbers of primary joint replacement procedures lead to increasing numbers of revision surgeries due to periprosthetic joint infections. Several studies revealed different patient-associated and intervention-associated risk factors. Importance should be pointed on short operating times to avoid intraoperative colonisation of the implant with microorganisms. Patient-associated diseases such as diabetes and obesity should be influenced positively in the preoperative setting. Cessation of smoking should be started two months before surgery and continued until wound healing is completed. Intraoperative single-shot antibiotic prophylaxis has become clinical routine. Prolonged perioperative antibiotic prophylaxis is often conducted but has not shown to be effective in lowering infection rates.

  20. Joint BioEnergy Institute

    SciTech Connect

    Keasling, Jay; Simmons, Blake; Tartaglino, Virginia; Baidoo, Edward; Kothari, Ankita

    2015-06-15

    The Joint BioEnergy Institute (JBEI) is a U.S. Department of Energy (DOE) Bioenergy Research Center dedicated to developing advanced biofuels—liquid fuels derived from the solar energy stored in plant biomass that can replace gasoline, diesel and jet fuels.

  1. Plating To Reinforce Welded Joints

    NASA Technical Reports Server (NTRS)

    Otousa, J. E.

    1982-01-01

    Electrodeposition used to strengthen welded joints gouged, nicked, or suffered other mechanical damage. Plating cell, typically of acrylic plastic such as poly (Methylmetacrylate), is assembled around part to be plated. Areas not to be plated are masked with plater's tape. Weld area is plated in standard nickel-plating process.

  2. Cryopumping field joint can testing

    NASA Astrophysics Data System (ADS)

    Johnson, Wesley; Fesmire, James; Meneghelli, Barry

    2012-06-01

    For long installations, vacuum jacketed piping often comes in 40 foot sections that are butt welded together in the field. A short can is then welded over the bare pipe connection to allow for insulation to be protected from the environment. Traditionally, the field joint is insulated with multilayer insulation and a vacuum is pulled on the can to minimize heat leak through the bare section and prevent frost from forming on the pipe section. The vacuum jacketed lines for the Ares I mobile launch platform were to be a combined 2000 feet long, with 60+ pipe sections and field joint cans. Historically, Kennedy Space Center has drilled a hole in the long sections to create a common vacuum with the field joint can to minimize maintenance on the vacuum jacketed piping. However, this effort looked at ways to use a passive system that didn't require a vacuum, but may cryopump to create its own vacuum. Various forms of aerogel, multilayer insulations, and combinations thereof were tested to determine the best method of insulating the field joint while minimizing maintenance and thermal losses.

  3. Cryopumping Field Joint Can Testing

    NASA Technical Reports Server (NTRS)

    Johnson, Wesley L.; Fesmire, James E.; Meneghelli, Barry E.

    2011-01-01

    For long installations, vacuum jacketed piping often comes in 40 foot sections that are butt welded together in the field. A short can is then welded over the bare pipe connection to allow for insulation to be protected from the environment. Traditionally, the field joint is insulated with multilayer insulation and a vacuum is pulled on the can to minimize heat leak through the bare section and prevent frost from forming on the pipe section. The vacuum jacketed lines for the Ares I mobile launch platform were to be a combined 2000 feet long, with 60+ pipe sections and field joint cans. Historically, Kennedy Space Center has drilled a hole in the long sections to create a common vacuum with the field joint can to minimize maintenance on the vacuum jacketed piping. However, this effort looked at ways to use a passive system that didn't require a vacuum, but may cryopump to create its own vacuum. Various forms of aerogel, multilayer insulations, and combinations thereof were tested to determine the best method of insulating the field joint while minimizing maintenance and thermal losses.

  4. Learning to Regulate Joint Action.

    ERIC Educational Resources Information Center

    Vila, Ignasi; Zanon, Javier

    Reported are implications of the genesis and development of joint action between Spanish adults and their infants for early first language acquisition. Focusing on the naturally occurring context of the "give and take" game format, this investigation discloses the role of the interaction pattern in the language acquisition process, including the…

  5. The Rationale for Joint Mobilization.

    ERIC Educational Resources Information Center

    Burkhardt, Sandy

    This paper presents an overview of the functions of connective tissue and the mechanisms of joint injury and contracture formation in relation to therapeutic exercise. The components of connective tissue operation are explained, including fibroblasts, macrophages, plasma cells, and collagen. An examination of the histology of connective tissue as…

  6. Stress-relieved solder joints

    NASA Technical Reports Server (NTRS)

    Zemenick, C. J.

    1980-01-01

    Mechanical stress on solder joints is reduced by procedure for soldering electronic components to circuit boards. Procedure was developed for radio-frequency (RF) strip-line circuits, for which dimensions must be carefully controlled to minimize parasitic capacitance and inductance. Procedure consists of loosening component from its mounting after each lead is soldered relieving induced stresses before next soldering step.

  7. The Joint Accomplishment of Identity

    ERIC Educational Resources Information Center

    Hand, Victoria; Gresalfi, Melissa

    2015-01-01

    Identity has become a central concept in the analysis of learning from social perspectives. In this article, we draw on a situative perspective to conceptualize identity as a "joint accomplishment" between individuals and their interactions with norms, practices, cultural tools, relationships, and institutional and cultural contexts.…

  8. Arthritis Mechanisms May Vary by Joint

    MedlinePlus

    ... Molecular differences between knee and hip joints with rheumatoid arthritis may inform more personal treatment strategies. Sebastian Kaulitzki/Hemera/Thinkstock Knee and hip joints with rheumatoid arthritis have differing genetic markers linked to inflammation, suggesting ...

  9. JAWS coordinates chondrogenesis and synovial joint positioning.

    PubMed

    Sohaskey, Michael L; Yu, Jane; Diaz, Michael A; Plaas, Anna H; Harland, Richard M

    2008-07-01

    Properly positioned synovial joints are crucial to coordinated skeletal movement. Despite their importance for skeletal development and function, the molecular mechanisms that underlie joint positioning are not well understood. We show that mice carrying an insertional mutation in a previously uncharacterized gene, which we have named Jaws (joints abnormal with splitting), die perinatally with striking skeletal defects, including ectopic interphalangeal joints. These ectopic joints develop along the longitudinal axis and persist at birth, suggesting that JAWS is uniquely required for the orientation and consequent positioning of interphalangeal joints within the endochondral skeleton. Jaws mutant mice also exhibit severe chondrodysplasia characterized by delayed and disorganized maturation of growth plate chondrocytes, together with impaired chondroitin sulfation and abnormal metabolism of the chondroitin sulfate proteoglycan aggrecan. Our findings identify JAWS as a key regulator of chondrogenesis and synovial joint positioning required for the restriction of joint formation to discrete stereotyped locations in the embryonic skeleton.

  10. Organizational aspects of physician joint ventures.

    PubMed

    Rublee, D A; Rosenfield, R H

    1987-03-01

    This article describes organizational forms of physician joint ventures. Four models are described that typify physician involvement in health care joint ventures: limited partnership syndication, venture capital company, provider network, and alternative delivery system. Important practical issues are discussed.

  11. Seismic response of rock joints and jointed rock mass

    SciTech Connect

    Ghosh, A.; Hsiung, S.M.; Chowdhury, A.H.

    1996-06-01

    Long-term stability of emplacement drifts and potential near-field fluid flow resulting from coupled effects are among the concerns for safe disposal of high-level nuclear waste (HLW). A number of factors can induce drift instability or change the near-field flow patterns. Repetitive seismic loads from earthquakes and thermal loads generated by the decay of emplaced waste are two significant factors. One of two key technical uncertainties (KTU) that can potentially pose a high risk of noncompliance with the performance objectives of 10 CFR Part 60 is the prediction of thermal-mechanical (including repetitive seismic load) effects on stability of emplacement drifts and the engineered barrier system. The second KTU of concern is the prediction of thermal-mechanical-hydrological (including repetitive seismic load) effects on the host rock surrounding the engineered barrier system. The Rock Mechanics research project being conducted at the Center for Nuclear Waste Regulatory Analyses (CNWRA) is intended to address certain specific technical issues associated with these two KTUs. This research project has two major components: (i) seismic response of rock joints and a jointed rock mass and (ii) coupled thermal-mechanical-hydrological (TMH) response of a jointed rock mass surrounding the engineered barrier system (EBS). This final report summarizes the research activities concerned with the repetitive seismic load aspect of both these KTUs.

  12. Joint laxity in the performing arts.

    PubMed

    Bird, H

    2016-05-25

    Traditional scoring systems for the assessment of joint flexibility are reviewed and reasons for variation in joint laxity are defined. The value of controlled joint laxity in the hands and arms of musicians is then discussed as well as the desirability of adjusting laxity at the various joints used in the different styles of dance, some of them ethnic, that depend on the specific articular characteristics of each different dancer.

  13. Revamped, joint ventures make a comeback.

    PubMed

    Peters, G R

    1991-08-01

    After a period of declining popularity, joint ventures are beginning to re-emerge as viable solution to challenges facing health care. Future joint ventures likely will be different, however, in response to problems and resulting legislation. Healthcare providers interested in starting a joint venture should consider five basic formats and some guidelines for developing them. Joint ventures ultimately may become a focal point for renewed efforts at regional healthcare planning.

  14. 49 CFR 583.15 - Joint ownership.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 7 2012-10-01 2012-10-01 false Joint ownership. 583.15 Section 583.15... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AUTOMOBILE PARTS CONTENT LABELING § 583.15 Joint... joint owners of a carline may designate, by written agreement, the manufacturer of record of...

  15. 49 CFR 583.15 - Joint ownership.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 7 2011-10-01 2011-10-01 false Joint ownership. 583.15 Section 583.15... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AUTOMOBILE PARTS CONTENT LABELING § 583.15 Joint... joint owners of a carline may designate, by written agreement, the manufacturer of record of...

  16. 14 CFR 399.37 - Joint fares.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 4 2011-01-01 2011-01-01 false Joint fares. 399.37 Section 399.37... STATEMENTS STATEMENTS OF GENERAL POLICY Policies Relating to Rates and Tariffs § 399.37 Joint fares. There should be joint fares in all markets over all routings within the contiguous 48 states and the...

  17. 49 CFR 1112.5 - Joint pleadings.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 8 2011-10-01 2011-10-01 false Joint pleadings. 1112.5 Section 1112.5... OF TRANSPORTATION RULES OF PRACTICE MODIFIED PROCEDURES § 1112.5 Joint pleadings. Parties with common interests are encouraged to prepare joint pleadings whenever possible....

  18. 49 CFR 225.23 - Joint operations.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Joint operations. 225.23 Section 225.23....23 Joint operations. (a) Any reportable death, injury, or illness of an employee arising from an accident/incident involving joint operations must be reported on Form FRA F 6180.55a by the...

  19. 49 CFR 178.338-4 - Joints.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Joints. 178.338-4 Section 178.338-4 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY... Containers for Motor Vehicle Transportation § 178.338-4 Joints. (a) All joints in the tank, and in the...

  20. 18 CFR 154.307 - Joint facilities.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 18 Conservation of Power and Water Resources 1 2011-04-01 2011-04-01 false Joint facilities. 154... Changes § 154.307 Joint facilities. The Statements required by § 154.312 must show all costs (investment... in the subject rate change and are associated with joint facilities. The methods used in making...

  1. 7 CFR 1400.203 - Joint operations.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 10 2012-01-01 2012-01-01 false Joint operations. 1400.203 Section 1400.203... AND SUBSEQUENT CROP, PROGRAM, OR FISCAL YEARS Payment Eligibility § 1400.203 Joint operations. (a) A member of a joint operation will be considered to be actively engaged in farming with respect to...

  2. 49 CFR 178.337-4 - Joints.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ..., see the List of CFR Sections Affected, which appears in the Finding Aids section of the printed volume... 49 Transportation 3 2012-10-01 2012-10-01 false Joints. 178.337-4 Section 178.337-4 Transportation... Containers for Motor Vehicle Transportation § 178.337-4 Joints. (a) Joints shall be as required in...

  3. 7 CFR 1956.110 - Joint debtors.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 14 2014-01-01 2014-01-01 false Joint debtors. 1956.110 Section 1956.110 Agriculture... REGULATIONS (CONTINUED) DEBT SETTLEMENT Debt Settlement-Community and Business Programs § 1956.110 Joint debtors. Settlements may not be approved for one joint debtor unless approved for all debtors....

  4. 14 CFR 25.693 - Joints.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Joints. 25.693 Section 25.693 Aeronautics... STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Systems § 25.693 Joints. Control system joints (in push-pull systems) that are subject to angular motion, except those in ball and...

  5. 7 CFR 1956.110 - Joint debtors.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 14 2012-01-01 2012-01-01 false Joint debtors. 1956.110 Section 1956.110 Agriculture... REGULATIONS (CONTINUED) DEBT SETTLEMENT Debt Settlement-Community and Business Programs § 1956.110 Joint debtors. Settlements may not be approved for one joint debtor unless approved for all debtors....

  6. 42 CFR 498.54 - Joint hearings.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Joint hearings. 498.54 Section 498.54 Public Health... PROGRAM Hearings § 498.54 Joint hearings. When two or more affected parties have requested hearings and... joint hearings are held, a single record of the preceedings is made and a separate decision issued...

  7. 7 CFR 1956.110 - Joint debtors.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 14 2011-01-01 2011-01-01 false Joint debtors. 1956.110 Section 1956.110 Agriculture... REGULATIONS (CONTINUED) DEBT SETTLEMENT Debt Settlement-Community and Business Programs § 1956.110 Joint debtors. Settlements may not be approved for one joint debtor unless approved for all debtors....

  8. 14 CFR 296.4 - Joint loading.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 4 2013-01-01 2013-01-01 false Joint loading. 296.4 Section 296.4... REGULATIONS INDIRECT AIR TRANSPORTATION OF PROPERTY General § 296.4 Joint loading. Nothing in this part shall preclude joint loading, meaning the pooling of shipments and their delivery to a direct air carrier...

  9. 14 CFR 296.4 - Joint loading.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 4 2012-01-01 2012-01-01 false Joint loading. 296.4 Section 296.4... REGULATIONS INDIRECT AIR TRANSPORTATION OF PROPERTY General § 296.4 Joint loading. Nothing in this part shall preclude joint loading, meaning the pooling of shipments and their delivery to a direct air carrier...

  10. 14 CFR 25.693 - Joints.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Joints. 25.693 Section 25.693 Aeronautics... STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Systems § 25.693 Joints. Control system joints (in push-pull systems) that are subject to angular motion, except those in ball and...

  11. 7 CFR 1400.203 - Joint operations.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 10 2013-01-01 2013-01-01 false Joint operations. 1400.203 Section 1400.203... AND SUBSEQUENT CROP, PROGRAM, OR FISCAL YEARS Payment Eligibility § 1400.203 Joint operations. (a) A member of a joint operation will be considered to be actively engaged in farming with respect to...

  12. 42 CFR 423.1040 - Joint hearings.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 3 2014-10-01 2014-10-01 false Joint hearings. 423.1040 Section 423.1040 Public... Penalties § 423.1040 Joint hearings. When two or more affected parties have requested hearings and the same... and place for the prehearing conference or hearing and conduct all proceedings jointly. If...

  13. 14 CFR 25.693 - Joints.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Joints. 25.693 Section 25.693 Aeronautics... STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Systems § 25.693 Joints. Control system joints (in push-pull systems) that are subject to angular motion, except those in ball and...

  14. 49 CFR 225.23 - Joint operations.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Joint operations. 225.23 Section 225.23....23 Joint operations. (a) Any reportable death, injury, or illness of an employee arising from an accident/incident involving joint operations must be reported on Form FRA F 6180.55a by the...

  15. 14 CFR 297.4 - Joint loading.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 4 2013-01-01 2013-01-01 false Joint loading. 297.4 Section 297.4... REGULATIONS FOREIGN AIR FREIGHT FORWARDERS AND FOREIGN COOPERATIVE SHIPPERS ASSOCIATIONS General § 297.4 Joint loading. Nothing in this part shall preclude joint loading, meaning the pooling of shipments and...

  16. 49 CFR 178.345-4 - Joints.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Joints. 178.345-4 Section 178.345-4 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY... Containers for Motor Vehicle Transportation § 178.345-4 Joints. (a) All joints between the cargo tank...

  17. 14 CFR 297.4 - Joint loading.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 4 2011-01-01 2011-01-01 false Joint loading. 297.4 Section 297.4... REGULATIONS FOREIGN AIR FREIGHT FORWARDERS AND FOREIGN COOPERATIVE SHIPPERS ASSOCIATIONS General § 297.4 Joint loading. Nothing in this part shall preclude joint loading, meaning the pooling of shipments and...

  18. 11 CFR 9034.8 - Joint fundraising.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 11 CFR 110.11, a joint fundraising notice shall be included with every solicitation for contributions... CFR 100.5; (B) The allocation formula to be used for distributing joint fundraising proceeds; (C) A... as defined in 11 CFR 110.3 prior to the joint fundraising activity and are not committees of the...

  19. 49 CFR 583.15 - Joint ownership.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 7 2013-10-01 2013-10-01 false Joint ownership. 583.15 Section 583.15... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AUTOMOBILE PARTS CONTENT LABELING § 583.15 Joint... joint owners of a carline may designate, by written agreement, the manufacturer of record of...

  20. 14 CFR 399.37 - Joint fares.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 4 2012-01-01 2012-01-01 false Joint fares. 399.37 Section 399.37... STATEMENTS STATEMENTS OF GENERAL POLICY Policies Relating to Rates and Tariffs § 399.37 Joint fares. There should be joint fares in all markets over all routings within the contiguous 48 states and the...

  1. 49 CFR 1112.5 - Joint pleadings.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 8 2014-10-01 2014-10-01 false Joint pleadings. 1112.5 Section 1112.5... OF TRANSPORTATION RULES OF PRACTICE MODIFIED PROCEDURES § 1112.5 Joint pleadings. Parties with common interests are encouraged to prepare joint pleadings whenever possible....

  2. 49 CFR 178.345-4 - Joints.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Joints. 178.345-4 Section 178.345-4 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY... Containers for Motor Vehicle Transportation § 178.345-4 Joints. (a) All joints between the cargo tank...

  3. 14 CFR 297.4 - Joint loading.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 4 2012-01-01 2012-01-01 false Joint loading. 297.4 Section 297.4... REGULATIONS FOREIGN AIR FREIGHT FORWARDERS AND FOREIGN COOPERATIVE SHIPPERS ASSOCIATIONS General § 297.4 Joint loading. Nothing in this part shall preclude joint loading, meaning the pooling of shipments and...

  4. 49 CFR 178.337-4 - Joints.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ..., see the List of CFR Sections Affected, which appears in the Finding Aids section of the printed volume... 49 Transportation 3 2014-10-01 2014-10-01 false Joints. 178.337-4 Section 178.337-4 Transportation... Containers for Motor Vehicle Transportation § 178.337-4 Joints. (a) Joints shall be as required in...

  5. 14 CFR 296.4 - Joint loading.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Joint loading. 296.4 Section 296.4... REGULATIONS INDIRECT AIR TRANSPORTATION OF PROPERTY General § 296.4 Joint loading. Nothing in this part shall preclude joint loading, meaning the pooling of shipments and their delivery to a direct air carrier...

  6. 18 CFR 154.307 - Joint facilities.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 18 Conservation of Power and Water Resources 1 2014-04-01 2014-04-01 false Joint facilities. 154... Changes § 154.307 Joint facilities. The Statements required by § 154.312 must show all costs (investment... in the subject rate change and are associated with joint facilities. The methods used in making...

  7. 11 CFR 9034.8 - Joint fundraising.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 11 CFR 110.11, a joint fundraising notice shall be included with every solicitation for contributions... CFR 100.5; (B) The allocation formula to be used for distributing joint fundraising proceeds; (C) A... as defined in 11 CFR 110.3 prior to the joint fundraising activity and are not committees of the...

  8. 42 CFR 498.54 - Joint hearings.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 5 2011-10-01 2011-10-01 false Joint hearings. 498.54 Section 498.54 Public Health... PROGRAM Hearings § 498.54 Joint hearings. When two or more affected parties have requested hearings and... joint hearings are held, a single record of the preceedings is made and a separate decision issued...

  9. 18 CFR 154.307 - Joint facilities.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 18 Conservation of Power and Water Resources 1 2013-04-01 2013-04-01 false Joint facilities. 154... Changes § 154.307 Joint facilities. The Statements required by § 154.312 must show all costs (investment... in the subject rate change and are associated with joint facilities. The methods used in making...

  10. 7 CFR 1956.110 - Joint debtors.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 14 2013-01-01 2013-01-01 false Joint debtors. 1956.110 Section 1956.110 Agriculture... REGULATIONS (CONTINUED) DEBT SETTLEMENT Debt Settlement-Community and Business Programs § 1956.110 Joint debtors. Settlements may not be approved for one joint debtor unless approved for all debtors....

  11. 42 CFR 423.1040 - Joint hearings.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 3 2013-10-01 2013-10-01 false Joint hearings. 423.1040 Section 423.1040 Public... Penalties § 423.1040 Joint hearings. When two or more affected parties have requested hearings and the same... and place for the prehearing conference or hearing and conduct all proceedings jointly. If...

  12. 49 CFR 178.338-4 - Joints.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Joints. 178.338-4 Section 178.338-4 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY... Containers for Motor Vehicle Transportation § 178.338-4 Joints. (a) All joints in the tank, and in the...

  13. 49 CFR 1112.5 - Joint pleadings.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 8 2013-10-01 2013-10-01 false Joint pleadings. 1112.5 Section 1112.5... OF TRANSPORTATION RULES OF PRACTICE MODIFIED PROCEDURES § 1112.5 Joint pleadings. Parties with common interests are encouraged to prepare joint pleadings whenever possible....

  14. 7 CFR 1400.203 - Joint operations.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 10 2010-01-01 2010-01-01 false Joint operations. 1400.203 Section 1400.203... AND SUBSEQUENT CROP, PROGRAM, OR FISCAL YEARS Payment Eligibility § 1400.203 Joint operations. (a) A member of a joint operation will be considered to be actively engaged in farming with respect to...

  15. 49 CFR 225.23 - Joint operations.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Joint operations. 225.23 Section 225.23....23 Joint operations. (a) Any reportable death, injury, or illness of an employee arising from an accident/incident involving joint operations must be reported on Form FRA F 6180.55a by the...

  16. 49 CFR 178.338-4 - Joints.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Joints. 178.338-4 Section 178.338-4 Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION... Containers for Motor Vehicle Transportation § 178.338-4 Joints. (a) All joints in the tank, and in the...

  17. 49 CFR 225.23 - Joint operations.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Joint operations. 225.23 Section 225.23....23 Joint operations. (a) Any reportable death, injury, or illness of an employee arising from an accident/incident involving joint operations must be reported on Form FRA F 6180.55a by the...

  18. 22 CFR 228.34 - Joint ventures.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Joint ventures. 228.34 Section 228.34 Foreign Relations AGENCY FOR INTERNATIONAL DEVELOPMENT RULES ON SOURCE, ORIGIN AND NATIONALITY FOR COMMODITIES AND... Financing § 228.34 Joint ventures. A joint venture or unincorporated association is eligible only if each...

  19. 49 CFR 178.345-4 - Joints.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Joints. 178.345-4 Section 178.345-4 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY... Containers for Motor Vehicle Transportation § 178.345-4 Joints. (a) All joints between the cargo tank...

  20. 7 CFR 1400.203 - Joint operations.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 10 2014-01-01 2014-01-01 false Joint operations. 1400.203 Section 1400.203... AND SUBSEQUENT CROP, PROGRAM, OR FISCAL YEARS Payment Eligibility § 1400.203 Joint operations. (a) A member of a joint operation will be considered to be actively engaged in farming with respect to...

  1. 18 CFR 154.307 - Joint facilities.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 18 Conservation of Power and Water Resources 1 2012-04-01 2012-04-01 false Joint facilities. 154... Changes § 154.307 Joint facilities. The Statements required by § 154.312 must show all costs (investment... in the subject rate change and are associated with joint facilities. The methods used in making...

  2. 49 CFR 178.338-4 - Joints.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Joints. 178.338-4 Section 178.338-4 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY... Containers for Motor Vehicle Transportation § 178.338-4 Joints. (a) All joints in the tank, and in the...

  3. 42 CFR 498.54 - Joint hearings.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 5 2012-10-01 2012-10-01 false Joint hearings. 498.54 Section 498.54 Public Health... PROGRAM Hearings § 498.54 Joint hearings. When two or more affected parties have requested hearings and... joint hearings are held, a single record of the preceedings is made and a separate decision issued...

  4. 49 CFR 192.233 - Miter joints.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 3 2014-10-01 2014-10-01 false Miter joints. 192.233 Section 192.233... BY PIPELINE: MINIMUM FEDERAL SAFETY STANDARDS Welding of Steel in Pipelines § 192.233 Miter joints. (a) A miter joint on steel pipe to be operated at a pressure that produces a hoop stress of...

  5. 14 CFR 297.4 - Joint loading.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Joint loading. 297.4 Section 297.4... REGULATIONS FOREIGN AIR FREIGHT FORWARDERS AND FOREIGN COOPERATIVE SHIPPERS ASSOCIATIONS General § 297.4 Joint loading. Nothing in this part shall preclude joint loading, meaning the pooling of shipments and...

  6. 49 CFR 1112.5 - Joint pleadings.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 8 2012-10-01 2012-10-01 false Joint pleadings. 1112.5 Section 1112.5... OF TRANSPORTATION RULES OF PRACTICE MODIFIED PROCEDURES § 1112.5 Joint pleadings. Parties with common interests are encouraged to prepare joint pleadings whenever possible....

  7. 14 CFR 399.37 - Joint fares.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 4 2014-01-01 2014-01-01 false Joint fares. 399.37 Section 399.37... STATEMENTS STATEMENTS OF GENERAL POLICY Policies Relating to Rates and Tariffs § 399.37 Joint fares. There should be joint fares in all markets over all routings within the contiguous 48 states and the...

  8. 11 CFR 9034.8 - Joint fundraising.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 11 CFR 110.11, a joint fundraising notice shall be included with every solicitation for contributions... CFR 100.5; (B) The allocation formula to be used for distributing joint fundraising proceeds; (C) A... as defined in 11 CFR 110.3 prior to the joint fundraising activity and are not committees of the...

  9. 49 CFR 1112.5 - Joint pleadings.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 8 2010-10-01 2010-10-01 false Joint pleadings. 1112.5 Section 1112.5... OF TRANSPORTATION RULES OF PRACTICE MODIFIED PROCEDURES § 1112.5 Joint pleadings. Parties with common interests are encouraged to prepare joint pleadings whenever possible....

  10. 49 CFR 583.15 - Joint ownership.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 7 2014-10-01 2014-10-01 false Joint ownership. 583.15 Section 583.15... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AUTOMOBILE PARTS CONTENT LABELING § 583.15 Joint... joint owners of a carline may designate, by written agreement, the manufacturer of record of...

  11. 49 CFR 178.337-4 - Joints.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., see the List of CFR Sections Affected which appears in the Finding Aids section of the printed volume... 49 Transportation 3 2011-10-01 2011-10-01 false Joints. 178.337-4 Section 178.337-4 Transportation... Containers for Motor Vehicle Transportation § 178.337-4 Joints. (a) Joints shall be as required in...

  12. 18 CFR 154.307 - Joint facilities.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Joint facilities. 154... Changes § 154.307 Joint facilities. The Statements required by § 154.312 must show all costs (investment... in the subject rate change and are associated with joint facilities. The methods used in making...

  13. 49 CFR 178.338-4 - Joints.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 3 2012-10-01 2012-10-01 false Joints. 178.338-4 Section 178.338-4 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY... Containers for Motor Vehicle Transportation § 178.338-4 Joints. (a) All joints in the tank, and in the...

  14. 42 CFR 423.1040 - Joint hearings.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 3 2012-10-01 2012-10-01 false Joint hearings. 423.1040 Section 423.1040 Public... Penalties § 423.1040 Joint hearings. When two or more affected parties have requested hearings and the same... and place for the prehearing conference or hearing and conduct all proceedings jointly. If...

  15. 14 CFR 25.693 - Joints.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Joints. 25.693 Section 25.693 Aeronautics... STANDARDS: TRANSPORT CATEGORY AIRPLANES Design and Construction Control Systems § 25.693 Joints. Control system joints (in push-pull systems) that are subject to angular motion, except those in ball and...

  16. 49 CFR 225.23 - Joint operations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Joint operations. 225.23 Section 225.23....23 Joint operations. (a) Any reportable death, injury, or illness of an employee arising from an accident/incident involving joint operations must be reported on Form FRA F 6180.55a by the...

  17. 14 CFR 296.4 - Joint loading.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 4 2011-01-01 2011-01-01 false Joint loading. 296.4 Section 296.4... REGULATIONS INDIRECT AIR TRANSPORTATION OF PROPERTY General § 296.4 Joint loading. Nothing in this part shall preclude joint loading, meaning the pooling of shipments and their delivery to a direct air carrier...

  18. 14 CFR 399.37 - Joint fares.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 4 2013-01-01 2013-01-01 false Joint fares. 399.37 Section 399.37... STATEMENTS STATEMENTS OF GENERAL POLICY Policies Relating to Rates and Tariffs § 399.37 Joint fares. There should be joint fares in all markets over all routings within the contiguous 48 states and the...

  19. 49 CFR 178.345-4 - Joints.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Joints. 178.345-4 Section 178.345-4 Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION... Containers for Motor Vehicle Transportation § 178.345-4 Joints. (a) All joints between the cargo tank...

  20. 7 CFR 1956.110 - Joint debtors.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 14 2010-01-01 2009-01-01 true Joint debtors. 1956.110 Section 1956.110 Agriculture... REGULATIONS (CONTINUED) DEBT SETTLEMENT Debt Settlement-Community and Business Programs § 1956.110 Joint debtors. Settlements may not be approved for one joint debtor unless approved for all debtors....

  1. 14 CFR 296.4 - Joint loading.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 4 2014-01-01 2014-01-01 false Joint loading. 296.4 Section 296.4... REGULATIONS INDIRECT AIR TRANSPORTATION OF PROPERTY General § 296.4 Joint loading. Nothing in this part shall preclude joint loading, meaning the pooling of shipments and their delivery to a direct air carrier...

  2. 42 CFR 498.54 - Joint hearings.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 5 2014-10-01 2014-10-01 false Joint hearings. 498.54 Section 498.54 Public Health... PROGRAM Hearings § 498.54 Joint hearings. When two or more affected parties have requested hearings and... joint hearings are held, a single record of the proceedings is made and a separate decision issued...

  3. 49 CFR 178.345-4 - Joints.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 3 2013-10-01 2013-10-01 false Joints. 178.345-4 Section 178.345-4 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY... Containers for Motor Vehicle Transportation § 178.345-4 Joints. (a) All joints between the cargo tank...

  4. 22 CFR 228.34 - Joint ventures.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 22 Foreign Relations 1 2011-04-01 2011-04-01 false Joint ventures. 228.34 Section 228.34 Foreign Relations AGENCY FOR INTERNATIONAL DEVELOPMENT RULES ON SOURCE, ORIGIN AND NATIONALITY FOR COMMODITIES AND... Financing § 228.34 Joint ventures. A joint venture or unincorporated association is eligible only if each...

  5. 42 CFR 498.54 - Joint hearings.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 5 2013-10-01 2013-10-01 false Joint hearings. 498.54 Section 498.54 Public Health... PROGRAM Hearings § 498.54 Joint hearings. When two or more affected parties have requested hearings and... joint hearings are held, a single record of the proceedings is made and a separate decision issued...

  6. 49 CFR 583.15 - Joint ownership.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 7 2010-10-01 2010-10-01 false Joint ownership. 583.15 Section 583.15... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AUTOMOBILE PARTS CONTENT LABELING § 583.15 Joint... joint owners of a carline may designate, by written agreement, the manufacturer of record of...

  7. 7 CFR 1400.203 - Joint operations.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 10 2011-01-01 2011-01-01 false Joint operations. 1400.203 Section 1400.203... AND SUBSEQUENT CROP, PROGRAM, OR FISCAL YEARS Payment Eligibility § 1400.203 Joint operations. (a) A member of a joint operation will be considered to be actively engaged in farming with respect to...

  8. 11 CFR 9034.8 - Joint fundraising.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 11 CFR 110.11, a joint fundraising notice shall be included with every solicitation for contributions... CFR 100.5; (B) The allocation formula to be used for distributing joint fundraising proceeds; (C) A... as defined in 11 CFR 110.3 prior to the joint fundraising activity and are not committees of the...

  9. 14 CFR 297.4 - Joint loading.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 4 2014-01-01 2014-01-01 false Joint loading. 297.4 Section 297.4... REGULATIONS FOREIGN AIR FREIGHT FORWARDERS AND FOREIGN COOPERATIVE SHIPPERS ASSOCIATIONS General § 297.4 Joint loading. Nothing in this part shall preclude joint loading, meaning the pooling of shipments and...

  10. 11 CFR 9034.8 - Joint fundraising.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 11 CFR 110.11, a joint fundraising notice shall be included with every solicitation for contributions... CFR 100.5; (B) The allocation formula to be used for distributing joint fundraising proceeds; (C) A... as defined in 11 CFR 110.3 prior to the joint fundraising activity and are not committees of the...

  11. 38 CFR 4.66 - Sacroiliac joint.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2012-07-01 2012-07-01 false Sacroiliac joint. 4.66... DISABILITIES Disability Ratings The Musculoskeletal System § 4.66 Sacroiliac joint. The common cause of... joints should be considered as one anatomical segment for rating purposes. X-ray changes from...

  12. Navigating Joint Projects in Telephone Conversations

    ERIC Educational Resources Information Center

    Bangerter, Adrian; Clark, Herbert H.; Katz, Anna R.

    2004-01-01

    Conversation coordinates joint activities and the joint projects that compose them. Participants coordinate (1) vertical transitions on entering and exiting joint projects; and (2) horizontal transitions in continuing within them. Transitions are coordinated using project markers such as uh-huh, yeah, right, and okay. In the authors' proposal,…

  13. Approach to the child with joint inflammation.

    PubMed

    Berard, Roberta

    2012-04-01

    Arthritis is manifested as a swollen joint having at least 2 of the following conditions: limited range of motion, pain on movement, or warmth overlying the joint. This article discusses an approach to the evaluation of a child with arthritis of one (mono) or several (poly) joints. PMID:22560569

  14. 46 CFR 385.38 - Joint funding.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 8 2013-10-01 2013-10-01 false Joint funding. 385.38 Section 385.38 Shipping MARITIME... AGREEMENTS REGULATIONS General Policies § 385.38 Joint funding. (a) Pursuant to section 10(c) of the Act, MarAd is authorized to participate in joint funded projects with other Federal agencies in any...

  15. 46 CFR 385.38 - Joint funding.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 8 2012-10-01 2012-10-01 false Joint funding. 385.38 Section 385.38 Shipping MARITIME... AGREEMENTS REGULATIONS General Policies § 385.38 Joint funding. (a) Pursuant to section 10(c) of the Act, MarAd is authorized to participate in joint funded projects with other Federal agencies in any...

  16. 46 CFR 385.38 - Joint funding.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 8 2010-10-01 2010-10-01 false Joint funding. 385.38 Section 385.38 Shipping MARITIME... AGREEMENTS REGULATIONS General Policies § 385.38 Joint funding. (a) Pursuant to section 10(c) of the Act, MarAd is authorized to participate in joint funded projects with other Federal agencies in any...

  17. 46 CFR 385.38 - Joint funding.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 8 2014-10-01 2014-10-01 false Joint funding. 385.38 Section 385.38 Shipping MARITIME... AGREEMENTS REGULATIONS General Policies § 385.38 Joint funding. (a) Pursuant to section 10(c) of the Act, MarAd is authorized to participate in joint funded projects with other Federal agencies in any...

  18. 46 CFR 385.38 - Joint funding.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 8 2011-10-01 2011-10-01 false Joint funding. 385.38 Section 385.38 Shipping MARITIME... AGREEMENTS REGULATIONS General Policies § 385.38 Joint funding. (a) Pursuant to section 10(c) of the Act, MarAd is authorized to participate in joint funded projects with other Federal agencies in any...

  19. Approach to the child with joint inflammation.

    PubMed

    Berard, Roberta

    2012-04-01

    Arthritis is manifested as a swollen joint having at least 2 of the following conditions: limited range of motion, pain on movement, or warmth overlying the joint. This article discusses an approach to the evaluation of a child with arthritis of one (mono) or several (poly) joints.

  20. 12 CFR 347.107 - Joint ventures.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 4 2010-01-01 2010-01-01 false Joint ventures. 347.107 Section 347.107 Banks and Banking FEDERAL DEPOSIT INSURANCE CORPORATION REGULATIONS AND STATEMENTS OF GENERAL POLICY INTERNATIONAL BANKING § 347.107 Joint ventures. (a) Joint ventures. If a bank, directly or indirectly,...

  1. Establishing joint goals through observation

    NASA Astrophysics Data System (ADS)

    Van Wie, Michael

    1997-09-01

    When interacting with intelligent agents, it is vital to understand something of their intentions. Agents' intentions provide context in spoken deluge, help to define their future plans (and thus actions), and reveal information about their beliefs. We propose a method by which agents' intentions are inferred by observing their actions. Explicit communication among agents is not permitted. The joint intentions framework specifies the behaviors and obligations of agents that share in a cooperative intention. Our work focuses on the creation of such joint intentions through observation and plan recognition. The plan recognition structure uses Bayes nets to reason from observations to actions, and hidden Markov models to reason from sequences of actions to intent.

  2. Foldable self-erecting joint

    NASA Technical Reports Server (NTRS)

    Pelischek, T. E. (Inventor)

    1986-01-01

    The invention relates to a foldable self erecting joint which may be used to deploy the tetratruss frame of the proposed shuttle launched triangular space station. The frame must be folded into the payload bay of the space shuttle orbiter. To deploy the frame the tubes are automatically unfolded and once in position should remain safely. A pair of hinged, tubular members in which the hinging is located at corresponding portions of the members are used. The opposite edge portions are connected by spring-based toggle links which in the unfolded position of the members are nested against one of the members in substantial alignment and over-center for securely locking the joint in the unfolded position.

  3. Ultrasonic Welding of Hybrid Joints

    NASA Astrophysics Data System (ADS)

    Wagner, Guntram; Balle, Frank; Eifler, Dietmar

    2012-03-01

    A central research field of the Institute of Materials Science and Engineering at the University of Kaiserslautern (WKK), Germany, is the realization of innovative hybrid joints by ultrasonic metal welding. This article gives an overview of suitable ultrasonic welding systems as well as of essential machine and material parameters, which influence the quality of the welds. Besides the ultrasonic welding of dissimilar metals such as Al to Cu or Al to steels, the welds between newly developed materials like aluminum foam sandwiches or flat flexible cables also can be realized. Moreover, the joining of glass and ceramic to sheet metals is a point of interest at the WKK. By using the ultrasonic metal welding process, it is possible to realize metal/glass welds with tensile shear strengths of 50 MPa. For metal/ceramic joints, the shear strengths values up to 150 MPa were measured. Finally, selected results about the occurring bonding mechanisms will be discussed.

  4. Intermetallic Layers in Soldered Joints

    1998-12-10

    ILAG solves the one-dimensional partial differential equations describing the multiphase, multicomponent, solid-state diffusion-controlled growth of intermetallic layers in soldered joints. This software provides an analysis capability for materials researchers to examine intermetallic growth mechanisms in a wide variety of defense and commercial applications involving both traditional and advanced materials. ILAG calculates the interface positions of the layers, as well as the spatial distribution of constituent mass fractions, and outputs the results at user-prescribed simulation times.

  5. Metal-ceramic joint assembly

    DOEpatents

    Li, Jian

    2002-01-01

    A metal-ceramic joint assembly in which a brazing alloy is situated between metallic and ceramic members. The metallic member is either an aluminum-containing stainless steel, a high chromium-content ferritic stainless steel or an iron nickel alloy with a corrosion protection coating. The brazing alloy, in turn, is either an Au-based or Ni-based alloy with a brazing temperature in the range of 9500 to 1200.degree. C.

  6. Spring joint with overstrain sensor

    NASA Technical Reports Server (NTRS)

    Phelps, Peter M. (Inventor); Gaither, Bryan W. (Inventor)

    2011-01-01

    A flexible joint may include a conductive compression spring and a pair of non-conductive spring cages disposed at opposite ends of the compression spring to support the compression spring. A conductive member disposed inside the compression spring may extend between the pair of spring cages. One end of the conductive member may be fixed for movement with one of the spring cages and another end of the conductive member may be fixed for movement with the other of the spring cages.

  7. Jointed Holder For Welding Electrodes

    NASA Technical Reports Server (NTRS)

    Gilbert, Jeffrey L.

    1991-01-01

    Adjustable-angle holder enables use of standard straight electrode with custom-fabricated bent gas cup for welding in difficult-to-reach places. Electrode replaced easily, without removing cup, with aid of tool loosening miniature collet nut on holder. Consumes fewer electrodes for given amount of welding. Angle of holder continuously adjustable to fit angle of gas cup or geometry of part welded. Holder made double-jointed to accommodate gas cup having compound angles.

  8. [Gout in the temporomandibular joint].

    PubMed

    Deferm, J T; Barkhuysen, R; de Rooy, J; Coppen, C; Merkx, M Aw

    2016-06-01

    A 76-year-old woman, with a medical history of diabetes mellitus and hypertension, presented herself to an oral and maxillofacial surgeon with a sudden pre-auricular swelling of the right temporomandibular joint. As a result of the atypical clinical appearance and signs of local destruction in the initial panoramic x-ray, a malign process was first eliminated from consideration. With the aid of extensive diagnostics and an open biopsy, the diagnosis of gout was established. PMID:27275659

  9. Joint stabilizing projects in defense

    SciTech Connect

    Canavan, G.H.; Browne, J.C.; Joseph, R.J.

    1992-06-01

    Joint defensive projects could increase stability and decrease the alert rates of strategic forces. Areas include the defense of the US, Commonwealth of Independent States (CIS), and their allies against third world threats; protection against each other's accidental or unauthorized launches; and defense against intentional attacks. The most promising area appears to be defining interfaces for the handover of satellite warning and trajectory information, which applies to most phases of theater defense and mutual protection. 19 refs.

  10. Joint stabilizing projects in defense

    SciTech Connect

    Canavan, G.H.; Browne, J.C.; Joseph, R.J.

    1992-06-01

    Joint defensive projects could increase stability and decrease the alert rates of strategic forces. Areas include the defense of the US, Commonwealth of Independent States (CIS), and their allies against third world threats; protection against each other`s accidental or unauthorized launches; and defense against intentional attacks. The most promising area appears to be defining interfaces for the handover of satellite warning and trajectory information, which applies to most phases of theater defense and mutual protection. 19 refs.

  11. Laboratory experiments on columnar jointing

    NASA Astrophysics Data System (ADS)

    Goehring, L.; Morris, S. W.

    2003-12-01

    The mechanism causing columnar jointing has remained an enticing mystery since the basalt columns of the Giant's Causeway in N. Ireland were first reported to science in the 17th century. This phenomenon, in which shrinkage cracks form a quasi-hexagonal arrangement, has been shown to produce columns in starch, glass, coal, sandstone, and ice, as well as in a variety of lava flows. This suggests that this pattern-forming process is very general in nature. However, most studies of columnar jointing have been confined to field studies of basalt flows. Following Muller, we have experimented with desiccating corn starch in an effort to understand this pattern from a more general point of view. The diffusion and evaporation of water in starch is thought to be analogous to the diffusion and extraction of heat from a basalt flow. By combining direct sampling and x-ray tomography, fully 3D descriptions of columnar jointing were obtained with starch samples. We have characterized the pattern with several statistical indices, which describe its structure and relative disorder. These methods can resolve the ordering of the colonnade near the free surface. We identified two distinct mechanisms by which the mean column area increases during pattern evolution. We found both a slow, almost power-law increase in column area, as well as episodes of sudden catastrophic jumps in scale. The latter suggests that the column scale is not a simple single-valued function of drying rate, but rather a metastable state subject to hysteresis. Such metastable behaviour might explain a fundamental question about columnar jointing -- why the columns are so regular in the direction of their growth. Moreover, these experiments may help discriminate between the various theoretical models of this pattern forming process. Finally, our results lead to predictions that could be tested by field measurements on basaltic colonnades.

  12. Hydraulic fracturing of jointed formations

    SciTech Connect

    Murphy, H.D.; Fehler, M.C.

    1986-01-01

    Measured by volume, North America's largest hydraulic fracturing operations have been conducted at Fenton Hill, New Mexico to create geothermal energy reservoirs. In the largest operation 21,000 m/sup 3/ of water were injected into jointed granitic rock at a depth of 3.5 km. Microearthquakes induced by this injection were measured with geophones placed in five wells drilled into, or very close, to the reservoir, as well as 11 surface seismometers. The large volume of rock over which the microearthquakes were distributed indicates a mechanism of hydraulic stimulation which is at odds with conventional fracturing theory, which predicts failure along a plane which is perpendicular to the least compressive earth stress. A coupled rock mechanics/fluid flow model provides much of the explanation. Shear slippage along pre-existing joints in the rock is more easily induced than conventional tensile failure, particularly when the difference between minimum and maximum earth stresses is large and the joints are oriented at angles between 30 and 60 degrees to the principal earth stresses, and a low viscosity fluid like water is injected. Shear slippage results in local redistribution of stresses, which allows a branching, or dendritic, stimulation pattern to evolve, in agreement with the patterns of microearthquake locations. These results are qualitatively similar to the controversial process known as ''Kiel'' fracturing, in which sequential injections and shut-ins are repeated to create dendritic fractures for enhanced oil and gas recovery. However, we believe that the explanation is shear slippage of pre-existing joints and stress redistribution, not proppant bridging and fluid blocking as suggested by Kiel. 15 refs., 10 figs.

  13. Boom and chassis articulation joints

    NASA Technical Reports Server (NTRS)

    Murphy, Joel T., Jr.; Nguyen, Vien; Turner, Bonnie; Wheeler, Bobby; Williams, Kimberlyn

    1992-01-01

    The primary goal of our design project was to develop articulation joints for the chassis and boom of the proof-of-concept lunar vehicle. This is an ongoing project and the work of previous student groups was extensively reviewed. Some of the ideas generated are variations of past proposals. Although the project is funded by NASA/USRA, it is totally a student design effort.

  14. Symptomatic carpal coalition: scaphotrapezial joint.

    PubMed

    Campaigniac, Erin; Eskander, Mark; Jones, Marci

    2013-12-01

    Carpal coalition is an uncommon congenital abnormality that arises from incomplete cavitation of the common cartilaginous precursor that forms the carpal bones. When carpal coalition is discovered, it is typically an asymptomatic incidental radiographic finding, and is often bilateral. We present a case of symptomatic unilateral carpal coalition of the scaphotrapezial joint, which was treated by excising the fibrous coalition and placing an interposition fat graft. This treatment was effective in alleviating the patient's symptoms.

  15. Joint Commission on rock properties

    NASA Astrophysics Data System (ADS)

    A joint commission on Rock Properties for Petroleum Engineers (RPPE) has been established by the International Society of Rock Mechanics and the Society of Petroleum Engineers to set up data banks on the properties of sedimentary rocks encountered during drilling. Computer-based data banks of complete rock properties will be organized for sandstones (GRESA), shales (ARSHA) and carbonates (CARCA). The commission hopes to access data sources from members of the commission, private companies and the public domain.

  16. Space Suit Joint Torque Testing

    NASA Technical Reports Server (NTRS)

    Valish, Dana J.

    2011-01-01

    In 2009 and early 2010, a test was performed to quantify the torque required to manipulate joints in several existing operational and prototype space suits in an effort to develop joint torque requirements appropriate for a new Constellation Program space suit system. The same test method was levied on the Constellation space suit contractors to verify that their suit design meets the requirements. However, because the original test was set up and conducted by a single test operator there was some question as to whether this method was repeatable enough to be considered a standard verification method for Constellation or other future space suits. In order to validate the method itself, a representative subset of the previous test was repeated, using the same information that would be available to space suit contractors, but set up and conducted by someone not familiar with the previous test. The resultant data was compared using graphical and statistical analysis and a variance in torque values for some of the tested joints was apparent. Potential variables that could have affected the data were identified and re-testing was conducted in an attempt to eliminate these variables. The results of the retest will be used to determine if further testing and modification is necessary before the method can be validated.

  17. The Joint Damping Experiment (JDX)

    NASA Technical Reports Server (NTRS)

    Folkman, Steven L.; Bingham, Jeff G.; Crookston, Jess R.; Dutson, Joseph D.; Ferney, Brook D.; Ferney, Greg D.; Rowsell, Edwin A.

    1997-01-01

    The Joint Damping Experiment (JDX), flown on the Shuttle STS-69 Mission, is designed to measure the influence of gravity on the structural damping of a high precision three bay truss. Principal objectives are: (1) Measure vibration damping of a small-scale, pinjointed truss to determine how pin gaps give rise to gravity-dependent damping rates; (2) Evaluate the applicability of ground and low-g aircraft tests for predicting on-orbit behavior; and (3) Evaluate the ability of current nonlinear finite element codes to model the dynamic behavior of the truss. Damping of the truss was inferred from 'Twang' tests that involve plucking the truss structure and recording the decay of the oscillations. Results are summarized as follows. (1) Damping, rates can change by a factor of 3 to 8 through changing the truss orientation; (2) The addition of a few pinned joints to a truss structure can increase the damping by a factor as high as 30; (3) Damping is amplitude dependent; (4) As gravity induced preloads become large (truss long axis perpendicular to gravity vector) the damping is similar to non-pinjointed truss; (5) Impacting in joints drives higher modes in structure; (6) The torsion mode disappears if gravity induced preloads are low.

  18. Joint Acoustic and Modulation Frequency

    NASA Astrophysics Data System (ADS)

    Atlas, Les; Shamma, Shihab A.

    2003-12-01

    There is a considerable evidence that our perception of sound uses important features which is related to underlying signal modulations. This topic has been studied extensively via perceptual experiments, yet there are few, if any, well-developed signal processing methods which capitalize on or model these effects. We begin by summarizing evidence of the importance of modulation representations from psychophysical, physiological, and other sources. The concept of a two-dimensional joint acoustic and modulation frequency representation is proposed. A simple single sinusoidal amplitude modulator of a sinusoidal carrier is then used to illustrate properties of an unconstrained and ideal joint representation. Added constraints are required to remove or reduce undesired interference terms and to provide invertibility. It is then noted that the constraints would also apply to more general and complex cases of broader modulation and carriers. Applications in single-channel speaker separation and in audio coding are used to illustrate the applicability of this joint representation. Other applications in signal analysis and filtering are suggested.

  19. Temporomandibular joint diagnostics using CBCT.

    PubMed

    Larheim, T A; Abrahamsson, A-K; Kristensen, M; Arvidsson, L Z

    2015-01-01

    The present review will give an update on temporomandibular joint (TMJ) imaging using CBCT. It will focus on diagnostic accuracy and the value of CBCT compared with other imaging modalities for the evaluation of TMJs in different categories of patients; osteoarthritis (OA), juvenile OA, rheumatoid arthritis and related joint diseases, juvenile idiopathic arthritis and other intra-articular conditions. Finally, sections on other aspects of CBCT research related to the TMJ, clinical decision-making and concluding remarks are added. CBCT has emerged as a cost- and dose-effective imaging modality for the diagnostic assessment of a variety of TMJ conditions. The imaging modality has been found to be superior to conventional radiographical examinations as well as MRI in assessment of the TMJ. However, it should be emphasized that the diagnostic information obtained is limited to the morphology of the osseous joint components, cortical bone integrity and subcortical bone destruction/production. For evaluation of soft-tissue abnormalities, MRI is mandatory. There is an obvious need for research on the impact of CBCT examinations on patient outcome.

  20. Mechanical flexible joint design document

    NASA Technical Reports Server (NTRS)

    Daily, Vic

    1993-01-01

    The purpose of this report is to document the status of the Mechanical Flexible Joint (MFJ) Design Subtask with the intent of halting work on the design. Recommendations for future work is included in the case that the task is to be resumed. The MFJ is designed to eliminate two failure points from the current flex joint configuration, the inner 'tripod configuration' and the outer containment jacket. The MFJ will also be designed to flex 13.5 degrees and have three degrees of freedom. By having three degrees of freedom, the MFJ will allow the Low Pressure Fuel Duct to twist and remove the necessity to angulate the full 11 degrees currently required. The current flex joints are very labor intensive and very costly and a simple alternative is being sought. The MFJ is designed with a greater angular displacement, with three degrees of freedom, to reside in the same overall envelope, to meet weight constraints of the current bellows, to be compatible with cryogenic fuel and oxidizers, and also to be man-rated.

  1. Temporomandibular joint diagnostics using CBCT

    PubMed Central

    Abrahamsson, A-K; Kristensen, M; Arvidsson, L Z

    2015-01-01

    The present review will give an update on temporomandibular joint (TMJ) imaging using CBCT. It will focus on diagnostic accuracy and the value of CBCT compared with other imaging modalities for the evaluation of TMJs in different categories of patients; osteoarthritis (OA), juvenile OA, rheumatoid arthritis and related joint diseases, juvenile idiopathic arthritis and other intra-articular conditions. Finally, sections on other aspects of CBCT research related to the TMJ, clinical decision-making and concluding remarks are added. CBCT has emerged as a cost- and dose-effective imaging modality for the diagnostic assessment of a variety of TMJ conditions. The imaging modality has been found to be superior to conventional radiographical examinations as well as MRI in assessment of the TMJ. However, it should be emphasized that the diagnostic information obtained is limited to the morphology of the osseous joint components, cortical bone integrity and subcortical bone destruction/production. For evaluation of soft-tissue abnormalities, MRI is mandatory. There is an obvious need for research on the impact of CBCT examinations on patient outcome. PMID:25369205

  2. Study of joint designing on composite structures

    NASA Astrophysics Data System (ADS)

    Kazushi, Haruna

    In this paper, strength design techniques of CFRP mechanical joints and adhesively bonded joints were examined. Remarkable stress concentration generates at the mechanical hole edge and the adhesive edge, therefore an unskillful design of joints often causes a reduction in the strength of composite structures. In mechanical joints, a study on predicting the joint strength has been performed, but bearing failure that is most important failure mode for designing joints can not be predicted. So in this paper, the strength prediction method in consideration with bearing failure was examined. On the other hand, the criterion using the intensity of stress singularity was suggested in adhesive joints, but it was clarified in this paper, that this method can not be applied the prediction of the final failure strength. So the critical stress distribution of single-lap adhesive bonded carbon/epoxy joints was examined to obtain the failure criterion of the final failure. Moreover the simulation method for an internal stress generated by cure shrinkage of adhesive was also examined. In the proposed method for mechanical joint, 2-parameter criterion, that is combined the characteristic length with the Yamada-Sun criterion, was applied and the characteristic length for compression was determined from "bearing failure test" that was newly conceived to take bearing failure into consideration. In case of adhesive joints, it was thought that 2-parameter criterion was effective. So the prediction method using 2-parameter criterion was applied to other adhesive joints. Good agreement was obtained between predicted and experimental results in both mechanical and adhesive joints. And it was cleared that an internal stress could be simulated by the proposed method. Moreover, in mechanical joints, the most suitable stacking sequence, the reduction technique of interlaminar stress, and the elevation of joint strength by application of high toughness matrix were also shown. Consequently

  3. Analysis of NSTX TF Joint Voltage Measurements

    SciTech Connect

    R, Woolley

    2005-10-07

    This report presents findings of analyses of recorded current and voltage data associated with 72 electrical joints operating at high current and high mechanical stress. The analysis goal was to characterize the mechanical behavior of each joint and thus evaluate its mechanical supports. The joints are part of the toroidal field (TF) magnet system of the National Spherical Torus Experiment (NSTX) pulsed plasma device operating at the Princeton Plasma Physics Laboratory (PPPL). Since there is not sufficient space near the joints for much traditional mechanical instrumentation, small voltage probes were installed on each joint and their voltage monitoring waveforms have been recorded on sampling digitizers during each NSTX ''shot''.

  4. Small Joint Arthroscopy in the Foot.

    PubMed

    Reeves, Christopher L; Shane, Amber M; Payne, Trevor; Cavins, Zac

    2016-10-01

    Arthroscopy has advanced in the foot and ankle realm, leading to new innovative techniques designed toward treatment of small joint abnormality. A range of abnormalities that are currently widespread for arthroscopic treatment in larger joints continues to be translated to congruent modalities in the small joints. Small joint arthroscopy offers relief from foot ailments with a noninvasive element afforded by arthroscopy. Early studies have found comparable results from arthroscopic soft tissue procedures as well as arthrodesis of the small joints when compared with the standard open approach. PMID:27599441

  5. Peripheral joint involvement in psoriatic arthritis patients.

    PubMed

    Acosta Felquer, Maria Laura; FitzGerald, Oliver

    2015-01-01

    Peripheral joint involvement is a common, potentially debilitating feature of psoriatic arthritis (PsA). Joint involvement is commonly symmetrical and polyarticular similar to rheumatoid arthritis (RA) but it can also be oligoarticular, asymmetrical or occasionally monoarticular. Involvement of the distal interphalangeal joints is a feature which distinguishes PsA from RA. Articular involvement in PsA can be severe with a mutilating arthropathy found in about 5%. These patients are characterised clinically by digital shortening and on radiographs by erosion on both sides of the joint and/or osteolysis. Treatments targeting joint disease frequently reduces symptoms and signs resulting in prevention of damage progression.

  6. Evaluation and management of joint pain.

    PubMed

    Collyott, Cindy L; Brooks, Mirella Vasquez

    2008-01-01

    The purpose of this article was to provide a review for orthopaedic nurses and nurse practitioners who evaluate, manage, and care for patients with joint pain. Joint pain is a common complaint evaluated by primary care providers. The causation of joint pain is complicated to identify because of an extensive range of differential diagnosis. The history and physical examination are crucial components in evaluating and managing joint pain. The primary care provider uses clinical factors such as patient demographics, presence of inflammation, acute/chronic duration, extra-articular manifestations, pattern of joint involvement, and disease chronology. Many rheumatologic laboratory tests are nonspecific, but aspiration of the joint with synovial fluid analysis may provide diagnostic clues, especially to differentiate infection versus inflammation. Primary care providers utilize both pharmacologic and nonpharmacologic regimens to manage acute and chronic joint pain.

  7. Biotribology of artificial hip joints

    PubMed Central

    Di Puccio, Francesca; Mattei, Lorenza

    2015-01-01

    Hip arthroplasty can be considered one of the major successes of orthopedic surgery, with more than 350000 replacements performed every year in the United States with a constantly increasing rate. The main limitations to the lifespan of these devices are due to tribological aspects, in particular the wear of mating surfaces, which implies a loss of matter and modification of surface geometry. However, wear is a complex phenomenon, also involving lubrication and friction. The present paper deals with the tribological performance of hip implants and is organized in to three main sections. Firstly, the basic elements of tribology are presented, from contact mechanics of ball-in-socket joints to ultra high molecular weight polyethylene wear laws. Some fundamental equations are also reported, with the aim of providing the reader with some simple tools for tribological investigations. In the second section, the focus moves to artificial hip joints, defining materials and geometrical properties and discussing their friction, lubrication and wear characteristics. In particular, the features of different couplings, from metal-on-plastic to metal-on-metal and ceramic-on-ceramic, are discussed as well as the role of the head radius and clearance. How friction, lubrication and wear are interconnected and most of all how they are specific for each loading and kinematic condition is highlighted. Thus, the significant differences in patients and their lifestyles account for the high dispersion of clinical data. Furthermore, such consideration has raised a new discussion on the most suitable in vitro tests for hip implants as simplified gait cycles can be too far from effective implant working conditions. In the third section, the trends of hip implants in the years from 2003 to 2012 provided by the National Joint Registry of England, Wales and Northern Ireland are summarized and commented on in a discussion. PMID:25621213

  8. Space nuclear system expansion joints

    NASA Technical Reports Server (NTRS)

    Whitaker, W. D.; Shimazki, T. T.

    1973-01-01

    The engineering, design, and fabrication status of the expansion joint unit (EJU) to be employed in the NaK primary coolant piping loop of the 5-kwe Reactor thermoelectric system are described. Four EJU's are needed in the NaK primary coolant piping loop. The four EJU's which will be identical, utilize bellows as the flexing member, are hermetically sealed, and provide double containment. The bellows are of a nested-formed design, and are to be constructed of 1-ply thickness of 0.010-in. Inconel 718. The EJU's provide a minimum piping load margin of safety of +0.22.

  9. Adaptive strategy for joint measurements

    NASA Astrophysics Data System (ADS)

    Uola, Roope; Luoma, Kimmo; Moroder, Tobias; Heinosaari, Teiko

    2016-08-01

    We develop a technique to find simultaneous measurements for noisy quantum observables in finite-dimensional Hilbert spaces. We use the method to derive lower bounds for the noise needed to make incompatible measurements jointly measurable. Using our strategy together with recent developments in the field of one-sided quantum information processing we show that the attained lower bounds are tight for various symmetric sets of quantum measurements. We use this characterisation to prove the existence of so called 4-Specker sets, i.e. sets of four incompatible observables with compatible subsets in the qubit case.

  10. Management of acromioclavicular joint injuries.

    PubMed

    Stucken, Charlton; Cohen, Steven B

    2015-01-01

    Although recent advances have been made in the treatment of acromioclavicular (AC) joint injuries, they are still challenging for shoulder surgeons. There is a consensus that type I and II injuries should be treated nonoperatively, whereas acute type IV, V, and VI injuries should be treated surgically. There is no algorithm for correctly diagnosing and treating type III injuries, but the current trend is toward nonoperative treatment except for those with persistent symptoms and functional limitations after a course of conservative management. If surgery is indicated, newer anatomic techniques of reconstructing the coracoclavicular (CC) and AC ligaments are recommended.

  11. Joint venture on degree course.

    PubMed

    1987-12-19

    A ground breaking joint venture between South Glamorgan's Health Authority and Institute of Higher Education will bear fruit next year when the first students enrol for a new part time post registration degree course in nursing studies. The four-year course will be split into two equal sections, diploma and degree, and will be open to any first level registered nurse. Nurses who have already obtained their diploma will be able to opt in for the degree course only and there are plans to introduce access courses for applicants with the old London University Diploma so they too can qualify.

  12. Joint Center for Artificial Photosynthesis

    SciTech Connect

    Koval, Carl; Lee, Kenny; Houle, Frances; Lewis, Nate

    2013-12-10

    The Joint Center for Artificial Photosynthesis (JCAP) is the nation's largest research program dedicated to the development of an artificial solar-fuel generation technology. Established in 2010 as a U.S. Department of Energy (DOE) Energy Innovation Hub, JCAP aims to find a cost-effective method to produce fuels using only sunlight, water, and carbon dioxide as inputs. JCAP brings together more than 140 top scientists and researchers from the California Institute of Technology and its lead partner, Berkeley Lab, along with collaborators from the SLAC National Accelerator Laboratory, and the University of California campuses at Irvine and San Diego.

  13. Joint Center for Artificial Photosynthesis

    ScienceCinema

    Koval, Carl; Lee, Kenny; Houle, Frances; Lewis, Nate

    2016-07-12

    The Joint Center for Artificial Photosynthesis (JCAP) is the nation's largest research program dedicated to the development of an artificial solar-fuel generation technology. Established in 2010 as a U.S. Department of Energy (DOE) Energy Innovation Hub, JCAP aims to find a cost-effective method to produce fuels using only sunlight, water, and carbon dioxide as inputs. JCAP brings together more than 140 top scientists and researchers from the California Institute of Technology and its lead partner, Berkeley Lab, along with collaborators from the SLAC National Accelerator Laboratory, and the University of California campuses at Irvine and San Diego.

  14. Automatic locking knee brace joint

    NASA Technical Reports Server (NTRS)

    Weddendorf, Bruce (Inventor)

    1995-01-01

    This invention is an apparatus for controlling the pivotal movement of a knee brace comprising a tang-and-clevis joint that has been uniquely modified. Both the tang and the clevis have a set of teeth that, when engaged, can lock the tang and the clevis together. In addition, the tang is biased away from the clevis. Consequently, when there is no axial force (i.e., body weight) on the tang, the tang is free to pivot within the clevis. However, when an axial force is exerted on the tang, the tang is pushed into the clevis, both sets of teeth engage, and the tang and the clevis lock together.

  15. The Planar Shape of Rock Joints

    NASA Astrophysics Data System (ADS)

    Zhang, Lianyang; Einstein, Herbert H.

    2010-02-01

    Knowing the planar shape of discontinuities is important when characterizing discontinuities in a rock mass. However, the real discontinuity shape is rarely known, since the rock mass is usually inaccessible in three dimensions. Information on discontinuity shape is limited and often open to more than one interpretation. This paper discusses the planar shape of rock joints, the most common discontinuities in rock. First, a brief literature review about the shape of joints is presented, including some information on joint-surface morphology, inferences from observed trace lengths on different sampling planes, information based on experimental studies, and joint shapes assumed by different researchers. This review shows that joints not affected by adjacent geological structures such as bedding boundaries or pre-existing fractures tend to be elliptical (or approximately circular but rarely). Joints affected by or intersecting such geological structures tend to be rectangular. Then, using the general stereological relationship between trace length distributions and joint size distributions developed by Zhang et al. (Geotechnique 52(6):419-433, 2002) for elliptical joints, the effect of sampling plane orientation on trace lengths is investigated. This study explains why the average trace lengths of non-equidimensional (elliptical or similar polygonal) joints on two sampling planes can be about equal and thus the conclusion that rock joints are equidimensional (circular) drawn from the fact that the average trace lengths on two sampling planes are approximately equal can be wrong. Finally, methods for characterizing the shape and size of joints (elliptical or rectangular) from trace length data are recommended, and the appropriateness of using elliptical joint shapes to represent polygonal, especially rectangular, joints is discussed.

  16. Exploring Joint Disease Risk Prediction

    PubMed Central

    Wang, Xiang; Wang, Fei; Hu, Jianying; Sorrentino, Robert

    2014-01-01

    Disease risk prediction has been a central topic of medical informatics. Although various risk prediction models have been studied in the literature, the vast majority were designed to be single-task, i.e. they only consider one target disease at a time. This becomes a limitation when in practice we are dealing with two or more diseases that are related to each other in terms of sharing common comorbidities, symptoms, risk factors, etc., because single-task prediction models are not equipped to identify these associations across different tasks. In this paper we address this limitation by exploring the application of multi-task learning framework to joint disease risk prediction. Specifically, we characterize the disease relatedness by assuming that the risk predictors underlying these diseases have overlap. We develop an optimization-based formulation that can simultaneously predict the risk for all diseases and learn the shared predictors. Our model is applied to a real Electronic Health Record (EHR) database with 7,839 patients, among which 1,127 developed Congestive Heart Failure (CHF) and 477 developed Chronic Obstructive Pulmonary Disease (COPD). We demonstrate that a properly designed multi-task learning algorithm is viable for joint disease risk prediction and it can discover clinical insights that single-task models would overlook. PMID:25954429

  17. Cell Therapy in Joint Disorders

    PubMed Central

    Counsel, Peter D.; Bates, Daniel; Boyd, Richard; Connell, David A.

    2015-01-01

    Context: Articular cartilage possesses poor natural healing mechanisms, and a variety of non-cell-based and cell-based treatments aim to promote regeneration of hyaline cartilage. Data Sources: A review of the literature to December 2013 using PubMed with search criteria including the keywords stem cell, cell therapy, cell transplantation, cartilage, chondral, and chondrogenic. Study Selection: Forty-five articles were identified that employed local mesenchymal stem cell (MSC) therapy for joint disorders in humans. Nine comparative studies were identified, consisting of 3 randomized trials, 5 cohort studies, and 1 case-control study. Study Type: Clinical review. Level of Evidence: Level 4. Data Extraction: Studies were assessed for stem cell source, method of implantation, comparison groups, and concurrent surgical techniques. Results: Two studies comparing MSC treatment to autologous chondrocyte implantation found similar efficacy. Three studies reported clinical benefits with intra-articular MSC injection over non-MSC controls for cases undergoing debridement with or without marrow stimulation, although a randomized study found no significant clinical difference at 2-year follow-up but reported better 18-month magnetic resonance imaging and histologic scores in the MSC group. No human studies have compared intra-articular MSC therapy to non-MSC techniques for osteoarthritis in the absence of surgery. Conclusion: Mesenchymal stem cell–based therapies appear safe and effective for joint disorders in large animal preclinical models. Evidence for use in humans, particularly, comparison with more established treatments such as autologous chondrocyte implantation and microfracture, is limited. PMID:25553210

  18. Factors to consider in joint prosthesis systems

    PubMed Central

    Wolford, Larry M.

    2006-01-01

    In joint reconstruction, the techniques and materials that provide the best outcomes for patients have been debated. The main points of controversy relate to the use of hemiarthroplasties versus total joint prostheses with metal-on-metal versus metal-on-polyethylene articulations. This article investigates these areas as well as the applicability of the techniques and materials and the complications that can occur. Hypersensitivity to materials used in joint prostheses is relatively common but often unrecognized. Although the discussion applies to all joints, the temporomandibular joint (TMJ) is emphasized. For TMJ reconstruction, metal-on-polyethylene articulation in total joint prostheses provides better treatment outcomes than metal-on-metal articulation. PMID:17252041

  19. Synovial joints: from development to homeostasis.

    PubMed

    Longobardi, Lara; Li, Tieshi; Tagliafierro, Lidia; Temple, Joseph D; Willcockson, Helen H; Ye, Ping; Esposito, Alessandra; Xu, Fuhua; Spagnoli, Anna

    2015-02-01

    Synovial joint morphogenesis occurs through the condensation of mesenchymal cells into a non-cartilaginous region known as the interzone and the specification of progenitor cells that commit to the articular fate. Although several signaling molecules are expressed by the interzone, the mechanism is poorly understood. For treatments of cartilage injuries, it is critical to discover the presence of joint progenitor cells in adult tissues and their expression gene pattern. Potential stem cell niches have been found in different joint regions, such as the surface zone of articular cartilage, synovium, and groove of Ranvier. Inherited joint malformations as well as joint-degenerating conditions are often associated with other skeletal defects and may be seen as the failure of morphogenic factors to establish the correct microenvironment in cartilage and bone. Therefore, exploring how joints form can help us understand how cartilage and bone are damaged and develop drugs to reactivate this developing mechanism.

  20. Synovial Joints: from Development to Homeostasis

    PubMed Central

    Li, Tieshi; Tagliafierro, Lidia; Temple, Joseph D.; Willcockson, Helen H.; Ye, Ping; Esposito, Alessandra; Xu, Fuhua; Spagnoli, Anna

    2015-01-01

    Synovial joint morphogenesis occurs through the condensation of mesenchymal cells into a non-cartilaginous region known as interzone, and the specification of progenitor cells that commit to the articular fate. Although several signaling molecules are expressed by the interzone, the mechanism is poorly understood. For treatments of cartilage injuries, it is critical to discover the presence of joint progenitor cells in adult tissues and their expression gene pattern. Potential stem cells niches have been found in different joint regions, such as the surface zone of articular cartilage, synovium and groove of Ranvier. Inherited joint malformation as well as joint degenerating conditions are often associated with other skeletal defects, and may be seen as the failure of morphogenic factors to establish the correct microenvironment in cartilage and bone. Therefore, exploring how joints form can help us understand how cartilage and bone are damaged and to develop drugs to reactivate this developing mechanism. PMID:25431159

  1. Using Joint Interviews to Add Analytic Value.

    PubMed

    Polak, Louisa; Green, Judith

    2016-10-01

    Joint interviewing has been frequently used in health research, and is the subject of a growing methodological literature. We review this literature, and build on it by drawing on a case study of how people make decisions about taking statins. This highlights two ways in which a dyadic approach to joint interviewing can add analytic value compared with individual interviewing. First, the analysis of interaction within joint interviews can help to explicate tacit knowledge and to illuminate the range of often hard-to-access resources that are drawn upon in making decisions. Second, joint interviews mitigate some of the weaknesses of interviewing as a method for studying practices; we offer a cautious defense of the often-tacit assumption that the "naturalness" of joint interviews strengthens their credibility as the basis for analytic inferences. We suggest that joint interviews are a particularly appropriate method for studying complex shared practices such as making health decisions. PMID:25850721

  2. Flat H Frangible Joint Evolution

    NASA Technical Reports Server (NTRS)

    Diegelman, Thomas E.; Hinkel, Todd J.; Benjamin, Andrew; Rochon, Brian V.; Brown, Christopher W.

    2016-01-01

    Space vehicle staging and separation events require pyrotechnic devices. They are single-use mechanisms that cannot be tested, nor can failure-tolerant performance be demonstrated in actual flight articles prior to flight use. This necessitates the implementation of a robust design and test approach coupled with a fully redundant, failure-tolerant explosive mechanism to ensure that the system functions even in the event of a single failure. Historically, NASA has followed the single failure-tolerant (SFT) design philosophy for all human-rated spacecraft, including the Space Shuttle Program. Following the end of this program, aerospace companies proposed building the next generation human-rated vehicles with off-the-shelf, non-redundant, zero-failure-tolerant (ZFT) separation systems. Currently, spacecraft and launch vehicle providers for both the Orion and Commercial Crew Programs (CCPs) plan to deviate from the heritage safety approach and NASA's SFT human rating requirements. Both programs' partners have base-lined ZFT frangible joints for vehicle staging and fairing separation. These joints are commercially available from pyrotechnic vendors. Non-human-rated missions have flown them numerous times. The joints are relatively easy to integrate structurally within the spacecraft. In addition, the separation event is debris free, and the resultant pyro shock is lower than that of other design solutions. It is, however, a serious deficiency to lack failure tolerance. When used for critical applications on human-rated vehicles, a single failure could potentially lead to loss of crew (LOC) or loss of mission (LOM)). The Engineering and Safety & Mission Assurance directorates within the NASA Johnson Space Center took action to address this safety issue by initiating a project to develop a fully redundant, SFT frangible joint design, known as the Flat H. Critical to the ability to retrofit on launch vehicles being developed, the SFT mechanisms must fit within the same

  3. [Septic arthritis of thoracic facet joint].

    PubMed

    Ben Abdelghani, K; Gérard-Dran, D; Combe, B

    2009-08-01

    Septic arthritis of the facet joint is a rare condition. We report a case of septic arthritis of both a thoracic facet joint and a wrist. Clinical manifestations were consistent with a spondylodiscitis. Magnetic resonance imaging of the spine demonstrated infection of facet joints of T1 and T2. A surgical biopsy of the wrist isolated a type B streptococcus. The same organism was found in urine culture. The patient had an uneventful recovery on antibiotics.

  4. Hydraulic-Leak Detector for Hidden Joints

    NASA Technical Reports Server (NTRS)

    Anderson, G. E.; Loo, S.

    1986-01-01

    Slow leakage of fluid made obvious. Indicator consists of wick wrapped at one end around joint to be monitored. Wick absorbs hydraulic fluid leaking from joint and transmits to opposite end, located outside cover plate and visible to inspector. Leakage manifested as discoloration of outside end of wick. Indicator reveals leaks in hidden fittings on hydraulic lines. Fast inspection of joints without disassembly. Used in aerospace, petroleum, chemical, nuclear, and other industries where removing covers for inspection impossible, difficult, or time-consuming.

  5. Thermal treatment of dissimilar steels' welded joints

    NASA Astrophysics Data System (ADS)

    Nikulina, A. A.; Denisova, A. S.; Gradusov, I. N.; Ryabinkina, P. A.; Rushkovets, M. V.

    2016-04-01

    In this paper combinations of chrome-nickel steel and high-carbon steel, produced by flash butt welding after heat treatment, are investigated. Light and electron microscopic studies show that the welded joints after heat treatment have a complex structure consisting of several phases as initial welded joints. A martensite structure in welded joints after thermal treatment at 300... 800 °C has been found.

  6. Failure Assessment Diagram for Titanium Brazed Joints

    NASA Technical Reports Server (NTRS)

    Flom, Yury; Jones, Justin S.; Powell, Mollie M.; Puckett, David F.

    2011-01-01

    The interaction equation was used to predict failure in Ti-4V-6Al joints brazed with Al 1100 filler metal. The joints used in this study were geometrically similar to the joints in the brazed beryllium metering structure considered for the ATLAS telescope. This study confirmed that the interaction equation R(sub sigma) + R(sub Tau) = 1, where R(sub sigma) and R(sub Tau)are normal and shear stress ratios, can be used as conservative lower bound estimate of the failure criterion in ATLAS brazed joints as well as for construction of the Failure Assessment Diagram (FAD).

  7. Life Estimation of Hip Joint Prosthesis

    NASA Astrophysics Data System (ADS)

    Desai, C.; Hirani, H.; Chawla, A.

    2014-11-01

    Hip joint is one of the largest weight-bearing structures in the human body. In the event of a failure of the natural hip joint, it is replaced with an artificial hip joint, known as hip joint prosthesis. The design of hip joint prosthesis must be such so as to resist fatigue failure of hip joint stem as well as bone cement, and minimize wear caused by sliding present between its head and socket. In the present paper an attempt is made to consider both fatigue and wear effects simultaneously in estimating functional-life of the hip joint prosthesis. The finite element modeling of hip joint prosthesis using HyperMesh™ (version 9) has been reported. The static analysis (load due to the dead weight of the body) and dynamic analysis (load due to walking cycle) have been described. Fatigue life is estimated by using the S-N curve of individual materials. To account for progressive wear of hip joint prosthesis, Archard's wear law, modifications in socket geometry and dynamic analysis have been used in a sequential manner. Using such sequential programming reduction in peak stress has been observed with increase in wear. Finally life is estimated on the basis of socket wear.

  8. Structural analysis of Aircraft fuselage splice joint

    NASA Astrophysics Data System (ADS)

    Udaya Prakash, R.; Kumar, G. Raj; Vijayanandh, R.; Senthil Kumar, M.; Ramganesh, T.

    2016-09-01

    In Aviation sector, composite materials and its application to each component are one of the prime factors of consideration due to the high strength to weight ratio, design flexibility and non-corrosive so that the composite materials are widely used in the low weight constructions and also it can be treated as a suitable alternative to metals. The objective of this paper is to estimate and compare the suitability of a composite skin joint in an aircraft fuselage with different joints by simulating the displacement, normal stress, vonmises stress and shear stress with the help of numerical solution methods. The reference Z-stringer component of this paper is modeled by CATIA and numerical simulation is carried out by ANSYS has been used for splice joint presents in the aircraft fuselage with three combinations of joints such as riveted joint, bonded joint and hybrid joint. Nowadays the stringers are using to avoid buckling of fuselage skin, it has joined together by rivets and they are connected end to end by splice joint. Design and static analysis of three-dimensional models of joints such as bonded, riveted and hybrid are carried out and results are compared.

  9. First Metatarsophalangeal Joint Arthroscopy for Osteochondral Lesions.

    PubMed

    Sherman, Thomas I; Kern, Michael; Marcel, John; Butler, Alexander; McGuigan, Francis X

    2016-06-01

    Small-joint arthroscopy has supplanted open procedures because it offers the potential for improvement in joint visualization, reduced scarring, and accelerated recovery. Despite these advantages, arthroscopy of the first metatarsophalangeal joint is not commonly performed and reports of its use are lacking. The reason for this is not clear but may be because of perceived technical complexity and poorly defined indications. In our experience, however, arthroscopy of the first metatarsophalangeal joint is a versatile procedure that facilitates treatment of many different pathologic processes through a minimally invasive approach with few complications. We present our technique for arthroscopic management of osteochondral lesions of the hallux. PMID:27656371

  10. Injuries to the acromioclavicular joint.

    PubMed

    Fraser-Moodie, J A; Shortt, N L; Robinson, C M

    2008-06-01

    Injuries to the acromioclavicular joint are common but underdiagnosed. Sprains and minor subluxations are best managed conservatively, but there is debate concerning the treatment of complete dislocations and the more complex combined injuries in which other elements of the shoulder girdle are damaged. Confusion has been caused by existing systems for classification of these injuries, the plethora of available operative techniques and the lack of well-designed clinical trials comparing alternative methods of management. Recent advances in arthroscopic surgery have produced an even greater variety of surgical options for which, as yet, there are no objective data on outcome of high quality. We review the current concepts of the treatment of these injuries.

  11. [Temporomandibular joint, occlusion and bruxism].

    PubMed

    Orthlieb, J D; Ré, J P; Jeany, M; Giraudeau, A

    2016-09-01

    Temporomandibular joint and dental occlusion are joined for better and worse. TMJ has its own weaknesses, sometimes indicated by bad functional habits and occlusal disorders. Occlusal analysis needs to be addressed simply and clearly. The term "malocclusion" is not reliable to build epidemiological studies, etiologic mechanisms or therapeutic advice on this "diagnosis". Understanding the impact of pathogenic malocclusion is not just about occlusal relationships that are more or less defective, it requires to locate them within the skeletal framework, the articular and behavioural context of the patient, and above all to assess their impact on the functions of the masticatory system. The TMJ-occlusion couple is often symbiotic, developing together in relation to its environment, compensating for its own shortcomings. However, a third partner may alter this relationship, such as bruxism, or more generally oral parafunctions, trauma or an interventionist practitioner. PMID:27523443

  12. Temperomandibular joint ankylosis in children

    PubMed Central

    Jayavelu, Perumal; Shrutha, S. P.; Vinit, G. B.

    2014-01-01

    Temperomandibular joint (TMJ) ankylosis or hypo mobility involves fusion of the mandibular condyle to the base of the skull. Impairment of speech, difficulty in mastication, poor oral hygiene, rampant caries, and acute compromise of the airway pose a severe psychological burden on the tender minds of children. The treatment of TMJ ankylosis poses a significant challenge because of technical difficulties and a high incidence of recurrence. This report describes a case of 7-year-old with inability to open mouth, diagnosed with unilateral right bony TMJ ankylosis. The surgical approach consisted of inter-positional arthroplasty followed by physiotherapy. A detailed history, clinical and functional examination, and radiographic examination facilitating correct diagnosis followed by immediate surgical intervention and physiotherapy can help us to restore physical, psychological and emotional health of the child patient. PMID:25210367

  13. Pressure-actuated joint system

    NASA Technical Reports Server (NTRS)

    McGuire, John R. (Inventor)

    2004-01-01

    A pressure vessel is provided that includes first and second case segments mated with one another. First and second annular rubber layers are disposed inboard of the first and second case segments, respectively. The second annular rubber layer has a slot extending from the radial inner surface across a portion of its thickness to define a main body portion and a flexible portion. The flexible portion has an interfacing surface portion abutting against an interfacing surface portion of the first annular rubber layer to follow movement of the first annular rubber layer during operation of the pressure vessel. The slot receives pressurized gas and establishes a pressure-actuated joint between the interfacing surface portions. At least one of the interfacing surface portions has a plurality of enclosed and sealed recesses formed therein.

  14. Multistep joint bilateral depth upsampling

    NASA Astrophysics Data System (ADS)

    Riemens, A. K.; Gangwal, O. P.; Barenbrug, B.; Berretty, R.-P. M.

    2009-01-01

    Depth maps are used in many applications, e.g. 3D television, stereo matching, segmentation, etc. Often, depth maps are available at a lower resolution compared to the corresponding image data. For these applications, depth maps must be upsampled to the image resolution. Recently, joint bilateral filters are proposed to upsample depth maps in a single step. In this solution, a high-resolution output depth is computed as a weighted average of surrounding low-resolution depth values, where the weight calculation depends on spatial distance function and intensity range function on the related image data. Compared to that, we present two novel ideas. Firstly, we apply anti-alias prefiltering on the high-resolution image to derive an image at the same low resolution as the input depth map. The upsample filter uses samples from both the high-resolution and the low-resolution images in the range term of the bilateral filter. Secondly, we propose to perform the upsampling in multiple stages, refining the resolution by a factor of 2×2 at each stage. We show experimental results on the consequences of the aliasing issue, and we apply our method to two use cases: a high quality ground-truth depth map and a real-time generated depth map of lower quality. For the first use case a relatively small filter footprint is applied; the second use case benefits from a substantially larger footprint. These experiments show that the dual image resolution range function alleviates the aliasing artifacts and therefore improves the temporal stability of the output depth map. On both use cases, we achieved comparable or better image quality with respect to upsampling with the joint bilateral filter in a single step. On the former use case, we feature a reduction of a factor of 5 in computational cost, whereas on the latter use case, the cost saving is a factor of 50.

  15. Biofluid lubrication for artificial joints

    NASA Astrophysics Data System (ADS)

    Pendleton, Alice Mae

    This research investigated biofluid lubrication related to artificial joints using tribological and rheological approaches. Biofluids studied here represent two categories of fluids, base fluids and nanostructured biofluids. Base fluids were studied through comparison of synthetic fluids (simulated body fluid and hyaluronic acid) as well as natural biofluids (from dogs, horses, and humans) in terms of viscosity and fluid shear stress. The nano-structured biofluids were formed using molecules having well-defined shapes. Understanding nano-structured biofluids leads to new ways of design and synthesis of biofluids that are beneficial for artificial joint performance. Experimental approaches were utilized in the present research. This includes basic analysis of biofluids' property, such as viscosity, fluid shear stress, and shear rate using rheological experiments. Tribological investigation and surface characterization were conducted in order to understand effects of molecular and nanostructures on fluid lubrication. Workpiece surface structure and wear mechanisms were investigated using a scanning electron microscope and a transmission electron microscope. The surface topography was examined using a profilometer. The results demonstrated that with the adding of solid additives, such as crown ether or fullerene acted as rough as the other solids in the 3-body wear systems. In addition, the fullerene supplied low friction and low wear, which designates the lubrication purpose of this particular particle system. This dissertation is constructed of six chapters. The first chapter is an introduction to body fluids, as mentioned earlier. After Chapter II, it examines the motivation and approach of the present research, Chapter III discusses the experimental approaches, including materials, experimental setup, and conditions. In Chapter IV, lubrication properties of various fluids are discussed. The tribological properties and performance nanostructured biofluids are

  16. Joint Attention in Autism: Teaching Smiling Coordinated with Gaze to Respond to Joint Attention Bids

    ERIC Educational Resources Information Center

    Krstovska-Guerrero, Ivana; Jones, Emily A.

    2013-01-01

    Children with autism demonstrate early deficits in joint attention and expressions of affect. Interventions to teach joint attention have addressed gaze behavior, gestures, and vocalizations, but have not specifically taught an expression of positive affect such as smiling that tends to occur during joint attention interactions. Intervention was…

  17. Experimental Investigation of Composite Pressure Vessel Performance and Joint Stiffness for Pyramid and Inverted Pyramid Joints

    NASA Technical Reports Server (NTRS)

    Verhage, Joseph M.; Bower, Mark V.; Gilbert, Paul A. (Technical Monitor)

    2001-01-01

    The focus of this study is on the suitability in the application of classical laminate theory analysis tools for filament wound pressure vessels with adhesive laminated joints in particular: pressure vessel wall performance, joint stiffness and failure prediction. Two 18-inch diameter 12-ply filament wound pressure vessels were fabricated. One vessel was fabricated with a 24-ply pyramid laminated adhesive double strap butt joint. The second vessel was fabricated with the same number of plies in an inverted pyramid joint. Results from hydrostatic tests are presented. Experimental results were used as input to the computer programs GENLAM and Laminate, and the output compared to test. By using the axial stress resultant, the classical laminate theory results show a correlation within 1% to the experimental results in predicting the pressure vessel wall pressure performance. The prediction of joint stiffness for the two adhesive joints in the axial direction is within 1% of the experimental results. The calculated hoop direction joint stress resultant is 25% less than the measured resultant for both joint configurations. A correction factor is derived and used in the joint analysis. The correction factor is derived from the hoop stress resultant from the tank wall performance investigation. The vessel with the pyramid joint is determined to have failed in the joint area at a hydrostatic pressure 33% value below predicted failure. The vessel with the inverted pyramid joint failed in the wall acreage at a hydrostatic pressure within 10% of the actual failure pressure.

  18. Calculation of tubular joints as compound shells

    NASA Astrophysics Data System (ADS)

    Golovanov, A. I.

    A scheme for joining isoparametric finite shell elements with a bend in the middle surface is described. A solution is presented for the problem of the stress-strain state of a T-joint loaded by internal pressure. A refined scheme is proposed for calculating structures of this kind with allowance for the stiffness of the welded joint.

  19. The Role of Rehearsal in Joint Control

    ERIC Educational Resources Information Center

    Gutierrez, Rick D.

    2006-01-01

    Behavior analysts have offered accounts of the behavior involved in matching to sample and delayed matching to sample. But until recently have not offered a behavioral analysis of generalized matching-to-sample. The concept of joint control, however, seems especially suited to such an analysis The present study used a joint-control procedure to…

  20. 38 CFR 36.4308 - Joint loans.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2012-07-01 2012-07-01 false Joint loans. 36.4308 Section 36.4308 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS (CONTINUED) LOAN GUARANTY Guaranty or Insurance of Loans to Veterans With Electronic Reporting § 36.4308 Joint loans....

  1. 38 CFR 36.4509 - Joint loans.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2011-07-01 2011-07-01 false Joint loans. 36.4509 Section 36.4509 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS (CONTINUED) LOAN GUARANTY Direct Loans § 36.4509 Joint loans. (a) No loan will be made unless an eligible veteran is...

  2. 12 CFR 612.2157 - Joint employees.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 12 Banks and Banking 7 2012-01-01 2012-01-01 false Joint employees. 612.2157 Section 612.2157 Banks and Banking FARM CREDIT ADMINISTRATION FARM CREDIT SYSTEM STANDARDS OF CONDUCT AND REFERRAL OF KNOWN OR SUSPECTED CRIMINAL VIOLATIONS Standards of Conduct § 612.2157 Joint employees. No officer of...

  3. 12 CFR 612.2157 - Joint employees.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 6 2010-01-01 2010-01-01 false Joint employees. 612.2157 Section 612.2157 Banks and Banking FARM CREDIT ADMINISTRATION FARM CREDIT SYSTEM STANDARDS OF CONDUCT AND REFERRAL OF KNOWN OR SUSPECTED CRIMINAL VIOLATIONS Standards of Conduct § 612.2157 Joint employees. No officer of...

  4. 38 CFR 36.4210 - Joint loans.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2014-07-01 2014-07-01 false Joint loans. 36.4210 Section 36.4210 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS (CONTINUED) LOAN... General Provisions § 36.4210 Joint loans. (a) Except as provided in paragraph (b) of this section,...

  5. 12 CFR 612.2157 - Joint employees.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 12 Banks and Banking 7 2013-01-01 2013-01-01 false Joint employees. 612.2157 Section 612.2157 Banks and Banking FARM CREDIT ADMINISTRATION FARM CREDIT SYSTEM STANDARDS OF CONDUCT AND REFERRAL OF KNOWN OR SUSPECTED CRIMINAL VIOLATIONS Standards of Conduct § 612.2157 Joint employees. No officer of...

  6. 38 CFR 36.4210 - Joint loans.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2013-07-01 2013-07-01 false Joint loans. 36.4210 Section 36.4210 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS (CONTINUED) LOAN... General Provisions § 36.4210 Joint loans. (a) Except as provided in paragraph (b) of this section,...

  7. 38 CFR 36.4509 - Joint loans.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2010-07-01 2010-07-01 false Joint loans. 36.4509 Section 36.4509 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS (CONTINUED) LOAN GUARANTY Direct Loans § 36.4509 Joint loans. (a) No loan will be made unless an eligible veteran is...

  8. 12 CFR 612.2157 - Joint employees.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 12 Banks and Banking 7 2014-01-01 2014-01-01 false Joint employees. 612.2157 Section 612.2157 Banks and Banking FARM CREDIT ADMINISTRATION FARM CREDIT SYSTEM STANDARDS OF CONDUCT AND REFERRAL OF KNOWN OR SUSPECTED CRIMINAL VIOLATIONS Standards of Conduct § 612.2157 Joint employees. No officer of...

  9. 38 CFR 36.4308 - Joint loans.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2014-07-01 2014-07-01 false Joint loans. 36.4308 Section 36.4308 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS (CONTINUED) LOAN GUARANTY Guaranty or Insurance of Loans to Veterans With Electronic Reporting § 36.4308 Joint loans....

  10. 38 CFR 36.4210 - Joint loans.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2010-07-01 2010-07-01 false Joint loans. 36.4210 Section 36.4210 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS (CONTINUED) LOAN... General Provisions § 36.4210 Joint loans. (a) Except as provided in paragraph (b) of this section,...

  11. 24 CFR 570.308 - Joint requests.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... submission requirements of 24 CFR part 91 and covers all members of the joint recipient. ... 24 Housing and Urban Development 3 2012-04-01 2012-04-01 false Joint requests. 570.308 Section 570... DEVELOPMENT COMMUNITY FACILITIES COMMUNITY DEVELOPMENT BLOCK GRANTS Entitlement Grants § 570.308...

  12. 38 CFR 36.4509 - Joint loans.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2013-07-01 2013-07-01 false Joint loans. 36.4509 Section 36.4509 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS (CONTINUED) LOAN GUARANTY Direct Loans § 36.4509 Joint loans. (a) No loan will be made unless an eligible veteran is...

  13. 38 CFR 36.4210 - Joint loans.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2011-07-01 2011-07-01 false Joint loans. 36.4210 Section 36.4210 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS (CONTINUED) LOAN... General Provisions § 36.4210 Joint loans. (a) Except as provided in paragraph (b) of this section,...

  14. 38 CFR 36.4210 - Joint loans.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2012-07-01 2012-07-01 false Joint loans. 36.4210 Section 36.4210 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS (CONTINUED) LOAN... General Provisions § 36.4210 Joint loans. (a) Except as provided in paragraph (b) of this section,...

  15. 38 CFR 36.4308 - Joint loans.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2013-07-01 2013-07-01 false Joint loans. 36.4308 Section 36.4308 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS (CONTINUED) LOAN GUARANTY Guaranty or Insurance of Loans to Veterans With Electronic Reporting § 36.4308 Joint loans....

  16. 24 CFR 570.308 - Joint requests.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... submission requirements of 24 CFR part 91 and covers all members of the joint recipient. ... 24 Housing and Urban Development 3 2010-04-01 2010-04-01 false Joint requests. 570.308 Section 570... DEVELOPMENT COMMUNITY FACILITIES COMMUNITY DEVELOPMENT BLOCK GRANTS Entitlement Grants § 570.308...

  17. 38 CFR 36.4308 - Joint loans.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2010-07-01 2010-07-01 false Joint loans. 36.4308 Section 36.4308 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS (CONTINUED) LOAN GUARANTY Guaranty or Insurance of Loans to Veterans With Electronic Reporting § 36.4308 Joint loans....

  18. 38 CFR 36.4509 - Joint loans.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2014-07-01 2014-07-01 false Joint loans. 36.4509 Section 36.4509 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS (CONTINUED) LOAN GUARANTY Direct Loans § 36.4509 Joint loans. (a) No loan will be made unless an eligible veteran is...

  19. 24 CFR 570.308 - Joint requests.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... submission requirements of 24 CFR part 91 and covers all members of the joint recipient. ... 24 Housing and Urban Development 3 2011-04-01 2010-04-01 true Joint requests. 570.308 Section 570... DEVELOPMENT COMMUNITY FACILITIES COMMUNITY DEVELOPMENT BLOCK GRANTS Entitlement Grants § 570.308...

  20. 38 CFR 36.4509 - Joint loans.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2012-07-01 2012-07-01 false Joint loans. 36.4509 Section 36.4509 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS (CONTINUED) LOAN GUARANTY Direct Loans § 36.4509 Joint loans. (a) No loan will be made unless an eligible veteran is...

  1. 24 CFR 570.308 - Joint requests.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... submission requirements of 24 CFR part 91 and covers all members of the joint recipient. ... 24 Housing and Urban Development 3 2013-04-01 2013-04-01 false Joint requests. 570.308 Section 570... DEVELOPMENT COMMUNITY FACILITIES COMMUNITY DEVELOPMENT BLOCK GRANTS Entitlement Grants § 570.308...

  2. 24 CFR 570.308 - Joint requests.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... submission requirements of 24 CFR part 91 and covers all members of the joint recipient. ... 24 Housing and Urban Development 3 2014-04-01 2013-04-01 true Joint requests. 570.308 Section 570... DEVELOPMENT COMMUNITY FACILITIES COMMUNITY DEVELOPMENT BLOCK GRANTS Entitlement Grants § 570.308...

  3. 38 CFR 36.4308 - Joint loans.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 2 2011-07-01 2011-07-01 false Joint loans. 36.4308 Section 36.4308 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS (CONTINUED) LOAN GUARANTY Guaranty or Insurance of Loans to Veterans With Electronic Reporting § 36.4308 Joint loans....

  4. 12 CFR 612.2157 - Joint employees.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 12 Banks and Banking 6 2011-01-01 2011-01-01 false Joint employees. 612.2157 Section 612.2157 Banks and Banking FARM CREDIT ADMINISTRATION FARM CREDIT SYSTEM STANDARDS OF CONDUCT AND REFERRAL OF KNOWN OR SUSPECTED CRIMINAL VIOLATIONS Standards of Conduct § 612.2157 Joint employees. No officer of...

  5. 14 CFR 399.37 - Joint fares.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... should be joint fares in all markets over all routings within the contiguous 48 states and the District of Columbia as follows: (a) Level. The level shall not exceed the sum of the maximum local fares..., and in any event shall not exceed the sum of the actual local fares. (b) Division. Joint fares...

  6. How do infants recognize joint attention?

    PubMed

    Gustafsson, Erik; Brisson, Julie; Beaulieu, Christelle; Mainville, Marc; Mailloux, Dominique; Sirois, Sylvain

    2015-08-01

    The emergence of joint attention is still a matter of vigorous debate. It involves diverse hypotheses ranging from innate modules dedicated to intention reading to more neuro-constructivist approaches. The aim of this study was to assess whether 12-month-old infants are able to recognize a "joint attention" situation when observing such a social interaction. Using a violation-of-expectation paradigm, we habituated infants to a "joint attention" video and then compared their looking time durations between "divergent attention" videos and "joint attention" ones using a 2 (familiar or novel perceptual component)×2 (familiar or novel conceptual component) factorial design. These results were enriched with measures of pupil dilation, which are considered to be reliable measures of cognitive load. Infants looked longer at test events that involved novel speaker and divergent attention but no changes in infants' pupil dilation were observed in any conditions. Although looking time data suggest that infants may appreciate discrepancies from expectations related to joint attention behavior, in the absence of clear evidence from pupillometry, the results show no demonstration of understanding of joint attention, even at a tacit level. Our results suggest that infants may be sensitive to relevant perceptual variables in joint attention situations, which would help scaffold social cognitive development. This study supports a gradual, learning interpretation of how infants come to recognize, understand, and participate in joint attention.

  7. Suspending and Reinstating Joint Activities with Dialogue

    ERIC Educational Resources Information Center

    Chevalley, Eric; Bangerter, Adrian

    2010-01-01

    Interruptions are common in joint activities like conversations. Typically, interrupted participants suspend the activity, address the interruption, and then reinstate the activity. In conversation, people jointly commit to interact and to talk about a topic, establishing these commitments sequentially. When a commitment is suspended, face is…

  8. High temperature ceramic/metal joint structure

    DOEpatents

    Boyd, Gary L.

    1991-01-01

    A high temperature turbine engine includes a hybrid ceramic/metallic rotor member having ceramic/metal joint structure. The disclosed joint is able to endure higher temperatures than previously possible, and aids in controlling heat transfer in the rotor member.

  9. [Temporomandibular joint disorders: Physiotherapy and postural approaches].

    PubMed

    Breton-Torres, I; Trichot, S; Yachouh, J; Jammet, P

    2016-09-01

    Rehabilitation of temporomandibular joint dysfunctions has for a long time tried to treat symptoms: pain relief, joint kinetics restoration, disk re-capture by manual maneuvers. The authors present their own therapeutic approach, which is no longer limited to symptoms, but addresses the causes and identifies risk factors to prevent relapse. PMID:27522242

  10. Tuberculosis of the bones and joints

    SciTech Connect

    Martini, M.

    1988-01-01

    Bone and joint tuberculosis is common in developing countries, and surgeons in these countries are often faced with the dual problem of diagnosing and treating this disease. However, bone and joint tuberculosis has not yet completely disappeared from industrialized countries, either. This book discusses this issue.

  11. Development of the human elbow joint.

    PubMed

    Mérida-Velasco, J A; Sánchez-Montesinos, I; Espín-Ferra, J; Mérida-Velasco, J R; Rodríguez-Vázquez, J F; Jiménez-Collado, J

    2000-02-01

    Many studies have been published on the development of the human elbow joint, but authors disagree on its morphogenetic timetable. Most discrepancies center on the cavitation of the elbow joint (including the humeroradial, humeroulnar, and superior radioulnar joints), and the organization of the tunnel of the ulnar nerve. We summarize our observations on the development of the elbow joint in 49 serially sectioned human embryonic (n = 28) and fetal (n = 21) upper limbs. During week 12, ossification begins in the epiphyses of the elements comprising the elbow joint. At the end of the embryonic period, the shallow groove between the posterior aspect of the medial epicondyle and the olecranon process, begins to be visible. The elbow joint cavity appears in O'Rahilly stage 21 (51 days) at the level of the humeroulnar and humeroradial interzones. Formation of the cavity begins at the medialmost portion of the humeroradial interzone and the lateralmost portion of the humeroulnar interzone. The annular ligament begins to develop in O'Rahilly stage 21 (51 days), and the superior radioulnar joint cavity appears between this ligament and the lateral aspect of the head of the radius during O'Rahilly stage 23 (56 days). We established the morphogenetic timetable of the human elbow joint.

  12. Proceed with Caution: Advocating Joint Custody.

    ERIC Educational Resources Information Center

    Hagen, Jan L.

    1987-01-01

    Joint custody, the newest child custody alternative following divorce, is intended to benefit and serve the best interests of children. Unintended consequences, however, have been relatively unexplored, which raises questions as to the viability of joint custody for all families, regardless of social class, race, or ethnicity. Until further…

  13. An Operant Analysis of Joint Attention Skills

    ERIC Educational Resources Information Center

    Holth, Per

    2005-01-01

    Joint attention, a synchronizing of the attention of two or more persons, has been an increasing focus of research in cognitive developmental psychology. Research in this area has progressed mainly outside of behavior analysis, and behavior-analytic research and theory has tended to ignore the work on joint attention. It is argued here, on the one…

  14. How do infants recognize joint attention?

    PubMed

    Gustafsson, Erik; Brisson, Julie; Beaulieu, Christelle; Mainville, Marc; Mailloux, Dominique; Sirois, Sylvain

    2015-08-01

    The emergence of joint attention is still a matter of vigorous debate. It involves diverse hypotheses ranging from innate modules dedicated to intention reading to more neuro-constructivist approaches. The aim of this study was to assess whether 12-month-old infants are able to recognize a "joint attention" situation when observing such a social interaction. Using a violation-of-expectation paradigm, we habituated infants to a "joint attention" video and then compared their looking time durations between "divergent attention" videos and "joint attention" ones using a 2 (familiar or novel perceptual component)×2 (familiar or novel conceptual component) factorial design. These results were enriched with measures of pupil dilation, which are considered to be reliable measures of cognitive load. Infants looked longer at test events that involved novel speaker and divergent attention but no changes in infants' pupil dilation were observed in any conditions. Although looking time data suggest that infants may appreciate discrepancies from expectations related to joint attention behavior, in the absence of clear evidence from pupillometry, the results show no demonstration of understanding of joint attention, even at a tacit level. Our results suggest that infants may be sensitive to relevant perceptual variables in joint attention situations, which would help scaffold social cognitive development. This study supports a gradual, learning interpretation of how infants come to recognize, understand, and participate in joint attention. PMID:26036712

  15. The cricothyroid joint in elderly Japanese individuals.

    PubMed

    Serikawa, Masamitu; Yamamoto, Masahito; Kawamoto, Ai; Katori, Yukio; Kinoshita, Hideaki; Matsunaga, Satoru; Abe, Shin-Ichi

    2016-06-01

    Using 15 cricothyroid joint (CT joint) specimens obtained from donated cadavers of elderly individuals, we examined the morphologies of the ceratocricoid ligaments as well as the synovial tissue. The ligaments consistently contained abundant elastic fibers: the fibers tended to be straight on the anterior side in contrast to a mesh-like arrangement on the posterior side. Thick and/or long synovial folds were often evident in the CT joint. The synovial tissue usually contained CD68-positive macrophages, but the positive cells were often restricted to certain parts of the tissue. Factor VIII-positive capillaries were present but few in number, and CD3- or IgM-positive lymphocytes were absent in the synovial tissue. Degenerative changes in the joint cartilage, such as roughness or thinning, were often present, but no cartilage defects were evident. Therefore, in contrast to the small, non-weight-bearing joints of the musculoskeletal system, we considered the degeneration of the CT joint to be a specific, silent form of osteoarthritis. For high-pitched phonation and ossification of the laryngeal cartilage, the CT joint in elderly individuals seemed to maintain its anterior gliding and rotation with the aid of elastic fiber-rich tissues compensating for the loss of congruity between the joint cartilage surfaces. PMID:26286109

  16. 77 FR 39560 - International Joint Commission

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-03

    ... International Joint Commission International Joint Commission Invites Public Comment on Upper Great Lakes Report... final report of its International Upper Great Lakes Study Board, Lake Superior Regulation: Addressing Uncertainty in Upper Great Lakes Water Levels. Comments will be accepted at public hearings and by mail,...

  17. Joint Ventures: A New Agenda for Education.

    ERIC Educational Resources Information Center

    Griffin, Dean

    1989-01-01

    The author states that vocational education can join in partnerships with industry, labor, and government to contribute to economic development. Examples of current programs are included. The "joint venture" concept is explained and ideas for forming joint ventures are shared. (CH)

  18. Physician joint ventures: new opportunities and risks.

    PubMed

    Miller, Jeremy N

    2004-01-01

    Joint ventures involving physicians and institutions or lay investors had fallen out of favor in recent years because of concerns about transgressing government regulations. These regulations have now been clarified leading to a resurgent interest in these arrangements. This article outlines the business principles, control issues, legal setting, and the various modalities for joint venturing.

  19. Healthcare joint ventures a CFO primer.

    PubMed

    Boettiger, John R; Young, Teresa T

    2004-10-01

    Joint ventures can spread costs across the partners and bring in cash. Partners should be chosen carefully, taking into account expertise and resources offered, reputation, and benefits to be gained from the deal. Even after the joint venture is in place, it needs to be monitored regularly.

  20. Scanning for dollars. Joint ventures in imaging.

    PubMed

    Miller, Jeremy N

    2003-04-01

    What are the latest models for joint ventures in medical imaging? What compliance obstacles do medical groups face? This article covers the opportunities and possible hazards of adding imaging services to your practice. Unless an imaging joint venture is both financially and legally feasible, it's not worth doing.

  1. 14 CFR 27.935 - Shafting joints.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Shafting joints. 27.935 Section 27.935 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION AIRCRAFT AIRWORTHINESS STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Rotor Drive System § 27.935 Shafting joints. Each...

  2. The joint venture alternative to mergers.

    PubMed

    Enders, R J

    1995-02-01

    However, while a joint venture may be "safe" from antitrust challenge, it is not without some practical difficulties, especially with respect to consolidating services at one location or jointly offering services provided at multiple facilities. These practical concerns include: 1. Who will exercise operational management of the joint venture? 2. How will the joint venture deal with different pricing for services that will be provided at multiple locations? 3. What criteria will be used to decide the location at which consolidated tertiary services will be offered? 4. In what circumstances can the joint venture be unwound, either in its entirety or as to discrete functions? When clinical services have been consolidated at one location, there is an appropriate concern by the other hospital that it will be unable to provide or re-enter the market for those services if the joint venture dissolves. These operational concerns, of course, are not addressed in the Consent Decree. Thus, even if a joint venture relationship survives antitrust scrutiny, the parties must still negotiate and resolve these operational issues in order for the joint venture to be viable.

  3. Sensate Scaffolds Can Reliably Detect Joint Loading

    PubMed Central

    Bliss, C. L.; Szivek, J. A.; Tellis, B. C.; Margolis, D. S.; Schnepp, A. B.; Ruth, J. T.

    2008-01-01

    Treatment of cartilage defects is essential to the prevention of osteoarthritis. Scaffold-based cartilage tissue engineering shows promise as a viable technique to treat focal defects. Added functionality can be achieved by incorporating strain gauges into scaffolds, thereby providing a real-time diagnostic measurement of joint loading. Strain-gauged scaffolds were placed into the medial femoral condyles of 14 adult canine knees and benchtop tested. Loads between 75 and 130 N were applied to the stifle joints at 30°, 50°, and 70° of flexion. Strain-gauged scaffolds were able to reliably assess joint loading at all applied flexion angles and loads. Pressure sensitive films were used to determine joint surface pressures during loading and to assess the effect of scaffold placement on joint pressures. A comparison of peak pressures in control knees and joints with implanted scaffolds, as well as a comparison of pressures before and after scaffold placement, showed that strain-gauged scaffold implantation did not significantly alter joint pressures. Future studies could possibly use strain-gauged scaffolds to clinically establish normal joint loads and to determine loads that are damaging to both healthy and tissue-engineered cartilage. Strain-gauged scaffolds may significantly aid the development of a functional engineered cartilage tissue substitute as well as provide insight into the native environment of cartilage. PMID:16941586

  4. The Analysis of Adhesively Bonded Advanced Composite Joints Using Joint Finite Elements

    NASA Technical Reports Server (NTRS)

    Stapleton, Scott E.; Waas, Anthony M.

    2012-01-01

    The design and sizing of adhesively bonded joints has always been a major bottleneck in the design of composite vehicles. Dense finite element (FE) meshes are required to capture the full behavior of a joint numerically, but these dense meshes are impractical in vehicle-scale models where a course mesh is more desirable to make quick assessments and comparisons of different joint geometries. Analytical models are often helpful in sizing, but difficulties arise in coupling these models with full-vehicle FE models. Therefore, a joint FE was created which can be used within structural FE models to make quick assessments of bonded composite joints. The shape functions of the joint FE were found by solving the governing equations for a structural model for a joint. By analytically determining the shape functions of the joint FE, the complex joint behavior can be captured with very few elements. This joint FE was modified and used to consider adhesives with functionally graded material properties to reduce the peel stress concentrations located near adherend discontinuities. Several practical concerns impede the actual use of such adhesives. These include increased manufacturing complications, alterations to the grading due to adhesive flow during manufacturing, and whether changing the loading conditions significantly impact the effectiveness of the grading. An analytical study is conducted to address these three concerns. Furthermore, proof-of-concept testing is conducted to show the potential advantages of functionally graded adhesives. In this study, grading is achieved by strategically placing glass beads within the adhesive layer at different densities along the joint. Furthermore, the capability to model non-linear adhesive constitutive behavior with large rotations was developed, and progressive failure of the adhesive was modeled by re-meshing the joint as the adhesive fails. Results predicted using the joint FE was compared with experimental results for various

  5. The analysis of adhesively bonded advanced composite joints using joint finite elements

    NASA Astrophysics Data System (ADS)

    Stapleton, Scott E.

    The design and sizing of adhesively bonded joints has always been a major bottleneck in the design of composite vehicles. Dense finite element (FE) meshes are required to capture the full behavior of a joint numerically, but these dense meshes are impractical in vehicle-scale models where a course mesh is more desirable to make quick assessments and comparisons of different joint geometries. Analytical models are often helpful in sizing, but difficulties arise in coupling these models with full-vehicle FE models. Therefore, a joint FE was created which can be used within structural FE models to make quick assessments of bonded composite joints. The shape functions of the joint FE were found by solving the governing equations for a structural model for a joint. By analytically determining the shape functions of the joint FE, the complex joint behavior can be captured with very few elements. This joint FE was modified and used to consider adhesives with functionally graded material properties to reduce the peel stress concentrations located near adherend discontinuities. Several practical concerns impede the actual use of such adhesives. These include increased manufacturing complications, alterations to the grading due to adhesive flow during manufacturing, and whether changing the loading conditions significantly impact the effectiveness of the grading. An analytical study is conducted to address these three concerns. Furthermore, proof-of-concept testing is conducted to show the potential advantages of functionally graded adhesives. In this study, grading is achieved by strategically placing glass beads within the adhesive layer at different densities along the joint. Furthermore, the capability to model non-linear adhesive constitutive behavior with large rotations was developed, and progressive failure of the adhesive was modeled by re-meshing the joint as the adhesive fails. Results predicted using the joint FE was compared with experimental results for various

  6. The forelimb in walking horses: 2. Net joint moments and joint powers.

    PubMed

    Clayton, H M; Hodson, E; Lanovaz, J L

    2000-07-01

    The objective was to measure the net joint moments and joint powers for the joints of the equine forelimb during the walk. Videographic and force data were combined with morphometric information using an inverse dynamics method. During stance phase the predominant joint moment was on the palmar aspect of all forelimb joints except the shoulder, where the peak moment was considerably higher than at any other joint. The entire forelimb showed net energy absorption in both stance and swing phases. The elbow was the only joint that showed net generation of energy, which was used to maintain the limb in extension in early stance as the horse's body vaults over the limb and to drive protraction and retraction of the limb during swing. The carpus aligned the limb into a supportive strut, but did not play an important role in energy absorption or generation. A small burst of positive work on the flexor aspect at the start of breakover indicated that the carpus played an active role in initiating breakover during walking. The fetlock functioned elastically to store and release strain energy during stance. The coffin joint acted as an energy damper during most of stance with a small burst of energy generation on the flexor aspect as the joint flexed during breakover. The magnitude of the peak joint power during swing decreased in a proximal to distal sequence. It is concluded that the elbow joint is the main site of energy generation. The shoulder and coffin joints act as energy dampers during stance. The distal joints had very low joint powers and appeared to be driven by inertial forces during the swing phase. This information will be applied to describe how horses compensate for different lamenesses in terms of redistributing the functions of energy generation and absorption between joints.

  7. 46 CFR 56.30-15 - Expanded or rolled joints.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Expanded or rolled joints. 56.30-15 Section 56.30-15... APPURTENANCES Selection and Limitations of Piping Joints § 56.30-15 Expanded or rolled joints. (a) Expanded or rolled joints may be used where experience or test has demonstrated that the joint is suitable for...

  8. 46 CFR 56.30-15 - Expanded or rolled joints.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 2 2014-10-01 2014-10-01 false Expanded or rolled joints. 56.30-15 Section 56.30-15... APPURTENANCES Selection and Limitations of Piping Joints § 56.30-15 Expanded or rolled joints. (a) Expanded or rolled joints may be used where experience or test has demonstrated that the joint is suitable for...

  9. 46 CFR 56.30-15 - Expanded or rolled joints.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 2 2011-10-01 2011-10-01 false Expanded or rolled joints. 56.30-15 Section 56.30-15... APPURTENANCES Selection and Limitations of Piping Joints § 56.30-15 Expanded or rolled joints. (a) Expanded or rolled joints may be used where experience or test has demonstrated that the joint is suitable for...

  10. Chord, Tie Bar & Crossbracing Joint Detail in Plan; Crossbracing ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Chord, Tie Bar & Crossbracing Joint Detail in Plan; Crossbracing Center Joint Detail in Plan; Chord Joining Detail in Plan & Elevation; Chord, Panel Post, Tie Bar, & Diagonal Brace Joint Detail; Crossbracing Center Joint Detail in Section; Chord, Panel Post, Tie Bar & Horizontal Brace Joint Detail - Narrows Bridge, Spanning Sugar Creek at Old County Road 280 East, Marshall, Parke County, IN

  11. Anatomy and histology of the sacroiliac joints.

    PubMed

    Egund, Niels; Jurik, Anne Grethe

    2014-07-01

    The anatomy of joints provides an important basis for understanding the nature and imaging of pathologic lesions and their imaging appearance. This applies especially to the sacroiliac (SI) joints, which play a major role in the diagnosis of spondyloarthritis. They are composed of two different joint portions, a cartilage-covered portion ventrally and a ligamentous portion dorsally, and thus rather complex anatomically. Knowledge of anatomy and the corresponding normal imaging findings are important in the imaging diagnosis of sacroiliitis, especially by MR imaging. A certain distinction between the two joint portions by MR imaging is only obtainable by axial slice orientation. Together with a perpendicular coronal slice orientation, it provides adequate anatomical information and thereby a possibility for detecting the anatomical site of disease-specific characteristics and normal variants simulating disease. This overview describes current knowledge about the normal macroscopic and microscopic anatomy of the SI joints.

  12. MODELING UNDERGROUND STRUCTURE VULNERABILITY IN JOINTED ROCK

    SciTech Connect

    R. SWIFT; D. STEEDMAN

    2001-02-01

    The vulnerability of underground structures and openings in deep jointed rock to ground shock attack is of chief concern to military planning and security. Damage and/or loss of stability to a structure in jointed rock, often manifested as brittle failure and accompanied with block movement, can depend significantly on jointed properties, such as spacing, orientation, strength, and block character. We apply a hybrid Discrete Element Method combined with the Smooth Particle Hydrodynamics approach to simulate the MIGHTY NORTH event, a definitive high-explosive test performed on an aluminum lined cylindrical opening in jointed Salem limestone. Representing limestone with discrete elements having elastic-equivalence and explicit brittle tensile behavior and the liner as an elastic-plastic continuum provides good agreement with the experiment and damage obtained with finite-element simulations. Extending the approach to parameter variations shows damage is substantially altered by differences in joint geometry and liner properties.

  13. Temporomandibular joint involvement in ankylosing spondylitis

    PubMed Central

    Arora, Pallak; Amarnath, Janardhan; Ravindra, Setru Veerabhadrappa; Rallan, Mandeep

    2013-01-01

    Frequency of temporomandibular joint (TMJ) involvement in patients with ankylosing spondylitis (AS) has varied from 4% to 35%. It is more common in men and produces generalised stiffness in involved joints. Clinician should be suspicious of AS when a patient reports with painful restricted movements of joint, neck or back and with no trauma history. Conventional radiographic methods have allowed the demonstration of TMJ abnormalities in patients with AS, but CT is necessary to establish joint space relations and bony morphology. We describe a case of severe AS with TMJ involvement in a 40-year-old female patient and demonstrated TMJ changes on CT. A CT was able to demonstrate articular cartilage changes, disc- and joint abnormalities. Thus, if conventional radiographs in a symptomatic patient with rheumatic diseases are unable to demonstrate changes, CT can provide valuable additional information of the changes in the TMJ. PMID:23645650

  14. Joint interaction with embedded concretions: joint loading configurations inferred from propagation paths

    NASA Astrophysics Data System (ADS)

    McConaughy, David T.; Engelder, Terry

    1999-11-01

    The interaction between propagating joints and embedded concretions in a Devonian black shale near Seneca Lake, NY, permits identification of the loading configurations responsible for two joint sets of different ages striking at nearly the same orientation. The earlier set consists of systematic joints cut by later Alleghanian joints of the Appalachian Plateau. The later set consists of non-systematic curving cross joints that abut these same Alleghanian joints. Field evidence shows that concretions functioned as stiff inclusions in a compliant black shale. As a consequence of this elastic contrast, local perturbations in the remote stress field persisted around the concretions during burial, tectonic deformation, and exhumation. These stress perturbations influenced joint propagation paths of both joint sets. Our conclusions about loading configurations are based on finite-element modeling of the effect of the local stress perturbation on concretion-modified joint propagation. Modeling shows that the local stress perturbation from a thermoelastic loading was responsible for deflecting cross joints away from concretions in a curved propagation path near the concretion. This load configuration also led to arrest of cross joints before they penetrated the shale-concretion interface. At greater distances from the concretion, the propagation path of cross joints was controlled by the contemporary tectonic stress field. The interface between concretions and the surrounding shale was strongly bonded, as indicated by the crossing of the interface by some of the systematic ENE joints. Higher compressive stress levels within the concretions relative to the shale suppressed joint development in the concretion, causing the arrest of those joints once they had driven across the interface and a short distance into the concretion. Numerical modeling shows that interface penetration by the systematic ENE joints is consistent with a fluid load, the same loading configuration

  15. Of bugs and joints: the relationship between infection and joints.

    PubMed

    Espinoza, Luis R; García-Valladares, Ignacio

    2013-01-01

    The association between microbes and joints has existed since antiquity, and remains complex. Diagnosis is often times difficult to determine despite highly suspicious clinical characteristics for the presence of an underlying infection. Over the several past decades, considerable advances have occurred in diagnostic methodologies and therapy. However, the morbidity and mortality of septic arthritis remains high. Great advances have occurred in the diagnosis, pathogenesis, and therapeutic management of reactive arthritis, and there is evidence that when the responsible microorganism is Chlamydia trachomathis, complete remission and cure is possible. Emergent infections, especially viral, has been recognized, i.e. HIV, hepatitis C, and most recently Chikengunya virus, and in the case of HIV associated articular manifestations, the introduction of HAART has resulted in a decrease in the incidence and development of newer complications such as the immune reconstitution syndrome. The infectious etiology of rheumatoid arthritis is being strongly considered once again, and the exciting association with periodontal disease is at the forefront of intense research. The gut microbiota is also being investigated and new and most interesting data is being gathered of the potential role of commensal gut organisms and the pathogenesis of rheumatoid arthritis.

  16. Of bugs and joints: the relationship between infection and joints.

    PubMed

    Espinoza, Luis R; García-Valladares, Ignacio

    2013-01-01

    The association between microbes and joints has existed since antiquity, and remains complex. Diagnosis is often times difficult to determine despite highly suspicious clinical characteristics for the presence of an underlying infection. Over the several past decades, considerable advances have occurred in diagnostic methodologies and therapy. However, the morbidity and mortality of septic arthritis remains high. Great advances have occurred in the diagnosis, pathogenesis, and therapeutic management of reactive arthritis, and there is evidence that when the responsible microorganism is Chlamydia trachomathis, complete remission and cure is possible. Emergent infections, especially viral, has been recognized, i.e. HIV, hepatitis C, and most recently Chikengunya virus, and in the case of HIV associated articular manifestations, the introduction of HAART has resulted in a decrease in the incidence and development of newer complications such as the immune reconstitution syndrome. The infectious etiology of rheumatoid arthritis is being strongly considered once again, and the exciting association with periodontal disease is at the forefront of intense research. The gut microbiota is also being investigated and new and most interesting data is being gathered of the potential role of commensal gut organisms and the pathogenesis of rheumatoid arthritis. PMID:22944142

  17. Impact extractive fracture of jointed steel plates of a bolted joint

    NASA Astrophysics Data System (ADS)

    Daimaruya, M.; Fujiki, H.; Ambarita, H.

    2012-08-01

    This study is concerned with the development of a fracture criterion for the impact fracture of jointed steel plates of a bolted joint used in a car body. For the accurate prediction of crash characteristics of car bodies by computer-aided engineering (CAE), it is also necessary to examine the behavior and fracture of jointed steel plates subjected to impact loads. Although the actual impact fracture of jointed steel plates of a bolted joint used in cars is complicated, for simplifying the problem it might be classified into the shear fracture and the extractive fracture of jointed steel plates. Attention is given to the extractive fracture of jointed steel plates in this study. The extractive behavior and fracture of three kinds of steel plates used for cars are examined in experiments and numerical simulations. The impact extraction test of steel plates jointed by a bolt is performed using the one-bar method, together with the static test. In order to understand the mechanism of extractive fracture process of jointed steel plates, numerical simulations by a FEM code LS-DYNA are also carried out. The obtained results suggest that a stress-based fracture criterion may be developed for the impact extractive fracture of jointed steel plates of a bolted joint used in a car body.

  18. The shoulder and elbow joints and right and left sides demonstrate similar joint position sense.

    PubMed

    King, Jacqlyn; Harding, Elizabeth; Karduna, Andrew

    2013-01-01

    Proper orientation of the shoulder and elbow is necessary for accurate and precise positioning of the hand. The authors' goal was to compare these joints with an active joint position sense task, while also taking into account the effects of joint flexion angle and arm dominance. Fifteen healthy subjects were asked to replicate presented joint angles with a single degree of freedom active positioning protocol. There were no significant differences in angular joint position sense errors with respect to joint (shoulder vs. elbow) and side (left vs. right). However, when considering linear positioning, errors were lower for the elbow, due to a shorter lever arm. Also, as flexion angles increased toward 90°, there was a consistent pattern of lower errors for both joints.

  19. Atypical molecular profile for joint development in the avian costal joint.

    PubMed

    Winslow, B B; Burke, A C

    2010-10-01

    Development of synovial joints involves generation of cartilaginous anlagen, formation of interzones between cartilage anlagen, and cavitation of interzones to produce fluid filled cavities. Interzone development is not fully understood, but interzones are thought to develop from skeletogenic cells that are inhibited from further chondrogenic development by a cascade of gene expression including Wnt and Bmp family members. We examined the development of the rarely studied avian costal joint to better understand mechanisms of joint development. The costal joint is found within ribs, is morphologically similar to the metatarsophalangeal joint, and undergoes cavitation in a similar manner. In contrast to other interzones, Wnt14/9a, Gdf5, Chordin, Barx1, and Bapx1 are absent from the costal joint interzone, consistent with the absence of active β-catenin and phosphorylated Smad 1/5/8. However Autotaxin and Noggin are expressed. The molecular profile of the costal joint suggests there are alternative mechanisms of interzone development. PMID:20730871

  20. Joint shear strength of FRP reinforced concrete beam-column joints

    NASA Astrophysics Data System (ADS)

    Saravanan, Jagadeesan; Kumaran, Ganapathy

    2011-03-01

    An assessment of the joint shear strength of exterior concrete beam-column joints reinforced internally with Glass Fibre Reinforced Polymer (GFRP) reinforcements under monotonically increasing load on beams keeping constant load on columns is carried out in this study. Totally eighteen numbers of specimens are cast and tested for different parametric conditions like beam longitudinal reinforcement ratio, concrete strength, column reinforcement ratio, joint aspect ratio and influence of the joint stirrups at the joint. Also finite element analysis is performed to simulate the behaviour of the beam-column joints under various parametric conditions. Based on this study, a modified design equation is proposed for assessing the joint shear strength of the GFRP reinforced beam-column specimens based on the experimental results and the review of the prevailing design equations.

  1. Effect of joint damping and joint nonlinearity on the dynamics of space structures

    NASA Technical Reports Server (NTRS)

    Bowden, Mary; Dugundji, John

    1988-01-01

    Analyses of the effect of linear joint characteristics on the vibrations of a free-free, three-joint beam model show that increasing joint damping increases resonant frequencies and increases modal damping but only to the point where the joint gets 'locked up' by damping. This behavior is different from that predicted by modeling joint damping as proportional damping. Nonlinear analyses of the three-joint model with cubic springs at the joints show all the classical single DOF nonlinear response behavior at each resonance of the multiple DOF system: nondoubling of response for a doubling of forcing amplitude, multiple solutions, jump behavior, and resonant frequency shifts. These properties can be concisely quantified by characteristic backbone curves, which show the locus of resonant peaks for increasing forcing amplitude.

  2. Acromioclavicular joint instability: anatomy, biomechanics and evaluation.

    PubMed

    Saccomanno, Maristella F; DE Ieso, Carmine; Milano, Giuseppe

    2014-01-01

    Acromioclavicular (AC) joint instability is a common source of pain and disability. The injury is most commonly a result of a direct impact to the AC joint. The AC joint is surrounded by a capsule and has an intra-articular synovium and an articular cartilage interface. An articular disc is usually present in the joint, but this varies in size and shape. The AC joint capsule is quite thin, but has considerable ligamentous support; there are four AC ligaments: superior, inferior, anterior and posterior. The coracoclavicular (CC) ligament complex consists of the conoid and trapezoid ligaments. They insert on the posteromedial and anterolateral region of the undersurface of the distal clavicle, respectively. The coracoid origin of the trapezoid covers the posterior half of the coracoid dorsum; the conoid origin is more posterior on the base of the coracoid. Several biomechanical studies showed that horizontal stability of the AC joint is mediated by the AC ligaments while vertical stability is mediated by the CC ligaments. The radiographic classification of AC joint injuries described by Rockwood includes six types: in type I injuries the AC ligaments are sprained, but the joint is intact; in type II injuries, the AC ligaments are torn, but the CC ligaments are intact; in type III injuries both the AC and the CC ligaments are torn; type IV injuries are characterized by complete dislocation with posterior displacement of the distal clavicle into or through the fascia of the trapezius; type V injuries are characterized by a greater degree of soft tissue damage; type VI injuries are inferior AC joint dislocations into a subacromial or subcoracoid position. The diagnosis of AC joint instability can be based on historical data, physical examination and imaging studies. The cross body adduction stress test has the greatest sensitivity, followed by the AC resisted extension test and the O'Brien test. Proper radiographic evaluation of the AC joint is necessary. The Zanca view

  3. 46 CFR 56.30-15 - Expanded or rolled joints.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... rolled joints may be used where experience or test has demonstrated that the joint is suitable for the design conditions and where adequate provisions are made to prevent separation of the joint....

  4. 46 CFR 56.30-15 - Expanded or rolled joints.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... rolled joints may be used where experience or test has demonstrated that the joint is suitable for the design conditions and where adequate provisions are made to prevent separation of the joint....

  5. Chord Splicing & Joining Detail; Chord & CrossBracing Joint Details; ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Chord Splicing & Joining Detail; Chord & Cross-Bracing Joint Details; Cross Bracing Center Joint Detail; Chord & Diagonal Joint Detail - Vermont Covered Bridge, Highland Park, spanning Kokomo Creek at West end of Deffenbaugh Street (moved to), Kokomo, Howard County, IN

  6. Chord, Horizontal Tie Bar & Crossbracing Joint Details; Crossbracing Center ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Chord, Horizontal Tie Bar & Crossbracing Joint Details; Crossbracing Center Joint Detail; Chord, Panel Posts, Braces & Counterbrace Joint Detail - Brownsville Covered Bridge, Spanning East Fork Whitewater River (moved to Eagle Creek Park, Indianapolis), Brownsville, Union County, IN

  7. Joint ventures: to pursue or not to pursue?

    PubMed

    Blaszyk, Michael D; Hill-Mischel, Jody

    2007-11-01

    Hospitals should carefully select joint venture partners. The joint venture evaluation process should involve a high-level screen of strategic opportunities. Hospitals should develop a full business plan for the joint venture.

  8. Return to joint parental responsibility.

    PubMed

    Pierotti, D

    1993-10-01

    Along the frontiers of the former Soviet Union young women die every day because of the serious medical conditions preventing childbearing; they die because they are culturally obligated to reproduce. Such cultural codes led to the death of a 15-year-old girl who was killed by her immigrant father and other relatives because she wanted to live like her peers in the French city of Colmar. A 1992 visit of the author to Catalonia to discuss male reproductive roles made him reevaluate earlier views. Traditional sexist attitudes resulted in the expulsion of pregnant students from a nursing school by a male doctor who blamed them, while male partners were acquitted. Preparation for the conference in Barcelona by reviewing 20 years of work on male sexuality and family planning yielded only a few studies on male responsibility and the changing role of males. The advent of modern contraceptives has weakened male supremacy in Europe except among some immigrant families and religious extremists. Divorce and child custody laws, favoring the mother further, eroded male dominance. Even organizations have been formed to defend male rights. In vitro fertilization was endorsed by American lesbians in an article in 1993 reducing males to sperm donor status. Modern reproductive medical technology seems to have broken all limits; even elderly women can be made to conceive. These extreme examples indicate that the male-female relationships and joint responsibility for raising children in a family should be resuscitated based on equal terms for emotional stability and benefit of parents and progeny.

  9. Joint implementation: A phased approach

    SciTech Connect

    Vellinga, P.; Heintz, R.

    1995-11-01

    What is Joint Implementation (JI)? In the Framework Convention on Climate Change (FCCC) it is described as a mechanism for cooperation between parties to meet the objective of the convention. Important considerations in favor of the introduction of the concept of JI are: (1) JI schemes could stimulate development and technology cooperation through generating (often private company) resources that would otherwise not be mobilized for such purposes, and thus stimulate broader participation in abatement measures. (2) The financial and societal cost for greenhouse gas abatement measures varies strongly among the parties to the FCCC. Given the global nature of the problem, national boundaries should not be barriers for the identification and implementation of cost effective schemes. Important reservations with regard to the introduction of the concept are: (1) The mechanism could be used by the developed countries to buy their way out of their obligation to take the lead in combating climate change. Ironically, JI could have the effect that the poorer countries with relatively low marginal costs for limiting emissions or enhancing sinks would be sponsored to adjust their pattern of development, while emissions in the richer countries would continue to grow. (2) At present, there exists considerable uncertainties with respect to a number of technical matters, such as measuring the net environmental effect of a JI project. However, these technical problems can probably be solved in due course (along with the findings of the IPCC and experiences gained with JI).

  10. Joint Acoustic Propagation Experiment (JAPE)

    NASA Technical Reports Server (NTRS)

    Carnes, Benny L.; Olsen, Robert O.; Kennedy, Bruce W.

    1993-01-01

    The Joint Acoustic Propagation Experiment (JAPE), performed under the auspices of NATO and the Acoustics Working Group, was conducted at White Sands Missile Range, New Mexico, USA, during the period 11-28 Jul. 1991. JAPE consisted of 220 trials using various acoustic sources including speakers, propane cannon, various types of military vehicles, helicopters, a 155mm howitzer, and static high explosives. Of primary importance to the performance of these tests was the intensive characterization of the atmosphere before and during the trials. Because of the wide range of interests on the part of the participants, JAPE was organized in such a manner to provide a broad cross section of test configurations. These included short and long range propagation from fixed and moving vehicles, terrain masking, and vehicle detection. A number of independent trials were also performed by individual participating agencies using the assets available during JAPE. These tests, while not documented in this report, provided substantial and important data to those groups. Perhaps the most significant feature of JAPE is the establishment of a permanent data base which can be used by not only the participants but by others interested in acoustics. A follow-on test was performed by NASA LaRC during the period 19-29 Aug. 1991 at the same location. These trials consisted of 59 overflights of supersonic aircraft in order to establish the relationship between atmospheric turbulence and the received sonic boom energy at the surface.

  11. Ipsilateral Tibiotalar Joint Osteoarthritis Transferred to the Contralateral Tibiotalar Joint.

    PubMed

    Dugarte, Anthony; Bharwani, Sahil; Yoo, HoJun; Boiwka, Alexander Vondra; Tang, Jonathan E; Ahn, Uri M; Ahn, Nicholas U

    2016-07-01

    Classically, it is thought that pain or disability in one leg can stress the contralateral leg, leading to similar symptoms. The mechanism of action for subsequent dysfunction in the healthy limb is thought to involve compensatory changes that are used as a means to reduce stance phase time on the injured limb. This is believed to increase the forces distributed across the healthy limb, ultimately leading to injury. This belief has been challenged, as supportive literature is sparse. The goal of this study was to determine whether an association between tibiotalar (TT) osteoarthritis (OA) in the right vs left lower extremity exists, and whether injury to one lower extremity leads to degeneration in the contralateral lower extremity. The authors evaluated 704 TT joints to determine the presence of OA. A multiple linear regression was performed using a standard P value cutoff (P<.05) and 95% confidence interval. The absolute value of the difference between right and left TT OA was compared for specimens in each decade of life. Multiple regression analysis revealed a positive correlation between right and left TT OA, after correcting for age, sex, and race. Right TT vs left TT had a slope of 0.489 with a P value approaching 0. Findings indicated the absolute value of the difference between right and left TT OA was not zero, and this difference remains significant throughout life. Based on these findings, OA in one ankle does not appear to lead to accelerated OA in the contralateral ankle. [Orthopedics. 2016; 39(4):e664-e667.]. PMID:27286049

  12. Progressive Damage Analysis of Bonded Composite Joints

    NASA Technical Reports Server (NTRS)

    Leone, Frank A., Jr.; Girolamo, Donato; Davila, Carlos G.

    2012-01-01

    The present work is related to the development and application of progressive damage modeling techniques to bonded joint technology. The joint designs studied in this work include a conventional composite splice joint and a NASA-patented durable redundant joint. Both designs involve honeycomb sandwich structures with carbon/epoxy facesheets joined using adhesively bonded doublers.Progressive damage modeling allows for the prediction of the initiation and evolution of damage within a structure. For structures that include multiple material systems, such as the joint designs under consideration, the number of potential failure mechanisms that must be accounted for drastically increases the complexity of the analyses. Potential failure mechanisms include fiber fracture, intraply matrix cracking, delamination, core crushing, adhesive failure, and their interactions. The bonded joints were modeled using highly parametric, explicitly solved finite element models, with damage modeling implemented via custom user-written subroutines. Each ply was discretely meshed using three-dimensional solid elements. Layers of cohesive elements were included between each ply to account for the possibility of delaminations and were used to model the adhesive layers forming the joint. Good correlation with experimental results was achieved both in terms of load-displacement history and the predicted failure mechanism(s).

  13. Sealed joint structure for electrochemical device

    DOEpatents

    Tucker, Michael C; Jacobson, Craig P; De Jonghe, Lutgard C; Visco, Steven J

    2013-05-21

    Several members make up a joint in a high-temperature electrochemical device, wherein the various members perform different functions. The joint is useful for joining multiple cells (generally tubular modules) of an electrochemical device to produce a multi-cell segment-in-series stack for a solid oxide fuel cell, for instance. The joint includes sections that bond the joining members to each other; one or more seal sections that provide gas-tightness, and sections providing electrical connection and/or electrical insulation between the various joining members. A suitable joint configuration for an electrochemical device has a metal joint housing, a first porous electrode, a second porous electrode, separated from the first porous electrode by a solid electrolyte, and an insulating member disposed between the metal joint housing and the electrolyte and second electrode. One or more brazes structurally and electrically connects the first electrode to the metal joint housing and forms a gas tight seal between the first electrode and the second electrode.

  14. Real-time visualization of joint cavitation.

    PubMed

    Kawchuk, Gregory N; Fryer, Jerome; Jaremko, Jacob L; Zeng, Hongbo; Rowe, Lindsay; Thompson, Richard

    2015-01-01

    Cracking sounds emitted from human synovial joints have been attributed historically to the sudden collapse of a cavitation bubble formed as articular surfaces are separated. Unfortunately, bubble collapse as the source of joint cracking is inconsistent with many physical phenomena that define the joint cracking phenomenon. Here we present direct evidence from real-time magnetic resonance imaging that the mechanism of joint cracking is related to cavity formation rather than bubble collapse. In this study, ten metacarpophalangeal joints were studied by inserting the finger of interest into a flexible tube tightened around a length of cable used to provide long-axis traction. Before and after traction, static 3D T1-weighted magnetic resonance images were acquired. During traction, rapid cine magnetic resonance images were obtained from the joint midline at a rate of 3.2 frames per second until the cracking event occurred. As traction forces increased, real-time cine magnetic resonance imaging demonstrated rapid cavity inception at the time of joint separation and sound production after which the resulting cavity remained visible. Our results offer direct experimental evidence that joint cracking is associated with cavity inception rather than collapse of a pre-existing bubble. These observations are consistent with tribonucleation, a known process where opposing surfaces resist separation until a critical point where they then separate rapidly creating sustained gas cavities. Observed previously in vitro, this is the first in-vivo macroscopic demonstration of tribonucleation and as such, provides a new theoretical framework to investigate health outcomes associated with joint cracking.

  15. Inspection of Fusion Joints in Plastic Pipe

    SciTech Connect

    Connie Reichert

    2005-09-01

    The standard method of joining plastic pipe in the field is the butt fusion process. As in any pipeline application, joint quality greatly affects overall operational safety of the system. Currently no simple, reliable, cost-effective method exists for assessing the quality of fusion joints in the field. Visual examination and pressure testing are current nondestructive approaches, which do not provide any assurance about the long-term pipeline performance. This project developed, demonstrated, and validated an in-situ nondestructive inspection method for butt fusion joints in gas distribution plastic pipelines. The inspection system includes a laser-based image-recognition system that automatically generates and interprets digital images of pipe joints and assigns them a pass/fail rating, which eliminates operator bias in evaluating joint quality. An EWI-patented process, the Weld Zone Inspection Method (WZIM) was developed in which local heat is applied to the joint region to relax the residual stresses formed by the original joining operation, which reveals the surface condition of the joint. In cases where the joint is not formed under optimal conditions, and the intermolecular forces between contacting surfaces are not strong enough, the relaxation of macromolecules in the surface layer causes the material to pull back, revealing a fusion line. If the joint is sound, the bond line image does not develop. To establish initial feasibility of the approach, welds were performed under standard and nonstandard conditions. These welds were subjected to the WZIM and two destructive forms of testing: short-term tensile testing and long-term creep rupture testing. There appears to be a direct correlation between the WZIM and the destructive testing results. Although WZIM appears to be more sensitive than destructive testing can verify, the approach appears valid.

  16. Real-Time Visualization of Joint Cavitation

    PubMed Central

    Rowe, Lindsay

    2015-01-01

    Cracking sounds emitted from human synovial joints have been attributed historically to the sudden collapse of a cavitation bubble formed as articular surfaces are separated. Unfortunately, bubble collapse as the source of joint cracking is inconsistent with many physical phenomena that define the joint cracking phenomenon. Here we present direct evidence from real-time magnetic resonance imaging that the mechanism of joint cracking is related to cavity formation rather than bubble collapse. In this study, ten metacarpophalangeal joints were studied by inserting the finger of interest into a flexible tube tightened around a length of cable used to provide long-axis traction. Before and after traction, static 3D T1-weighted magnetic resonance images were acquired. During traction, rapid cine magnetic resonance images were obtained from the joint midline at a rate of 3.2 frames per second until the cracking event occurred. As traction forces increased, real-time cine magnetic resonance imaging demonstrated rapid cavity inception at the time of joint separation and sound production after which the resulting cavity remained visible. Our results offer direct experimental evidence that joint cracking is associated with cavity inception rather than collapse of a pre-existing bubble. These observations are consistent with tribonucleation, a known process where opposing surfaces resist separation until a critical point where they then separate rapidly creating sustained gas cavities. Observed previously in vitro, this is the first in-vivo macroscopic demonstration of tribonucleation and as such, provides a new theoretical framework to investigate health outcomes associated with joint cracking. PMID:25875374

  17. INSPECTION OF FUSION JOINTS IN PLASTIC PIPE

    SciTech Connect

    Alex Savitski; Connie Reichert; John Coffey

    2004-10-29

    The standard method of joining plastic pipe in the field is the butt fusion process. As in any pipeline application, joint quality greatly affects overall operational safety of the system. Currently no simple, reliable, cost effective method of assessing the quality of fusion joints in the field exists. Visual examination and pressure testing are current non-destructive approaches, which do not provide any assurance about the long-term pipeline performance. This project will develop, demonstrate, and validate an in-situ non-destructive inspection method for butt fusion joints in gas distribution plastic pipelines. The inspection system will include a laser based image-recognition system that will automatically generate and interpret digital images of pipe joints and assign them a pass/fail rating, which eliminates operator bias in evaluating joint quality. A Weld Zone Inspection Method (WZIM) is being developed in which local heat is applied to the joint region to relax the residual stresses formed by the original joining operation and reveal the surface condition of the joint. In cases where the joint is not formed under optimal conditions, and the intermolecular forces between contacting surfaces are not strong enough, the relaxation of macromolecules in the surface layer causes the material to pull back, revealing a fusion line. If the joint is sound, the bond line image does not develop. To establish initial feasibility of the approach, welds were performed under standard and non-standard conditions. These welds were subjected to the WZIM and tensile testing. There appears to be a direct correlation between the WZIM and tensile testing results. Although WZIM appears to be more sensitive than tensile testing can verify, the approach appears valid.

  18. INSPECTION OF FUSION JOINTS IN PLASTIC PIPE

    SciTech Connect

    Alex Savitski; Connie Reichert; John Coffey

    2004-07-13

    The standard method of joining plastic pipe in the field is the butt fusion process. As in any pipeline application, joint quality greatly affects overall operational safety of the system. Currently no simple, reliable, cost effective method of assessing the quality of fusion joints in the field exists. Visual examination and pressure testing are current non-destructive approaches, which do not provide any assurance about the long-term pipeline performance. This project will develop, demonstrate, and validate an in-situ non-destructive inspection method for butt fusion joints in gas distribution plastic pipelines. The inspection system will include a laser based image-recognition system that will automatically generate and interpret digital images of pipe joints and assign them a pass/fail rating, which eliminates operator bias in evaluating joint quality. A Weld Zone Inspection Method (WZIM) is being developed in which local heat is applied to the joint region to relax the residual stresses formed by the original joining operation and reveal the surface condition of the joint. In cases where the joint is not formed under optimal conditions, and the intermolecular forces between contacting surfaces are not strong enough, the relaxation of macromolecules in the surface layer causes the material to pull back, revealing a fusion line. If the joint is sound, the bond line image does not develop. To establish initial feasibility of the approach, welds were performed under standard and non-standard conditions. These welds were subjected to the WZIM and tensile testing. There appears to be a direct correlation between the WZIM and tensile testing results. Although WZIM appears to be more sensitive than tensile testing can verify, the approach appears valid.

  19. INSPECTION OF FUSION JOINTS IN PLASTIC PIPE

    SciTech Connect

    Alex Savitski; Connie Reichert; John Coffey

    2005-07-13

    The standard method of joining plastic pipe in the field is the butt fusion process. As in any pipeline application, joint quality greatly affects overall operational safety of the system. Currently no simple, reliable, cost effective method of assessing the quality of fusion joints in the field exists. Visual examination and pressure testing are current non-destructive approaches, which do not provide any assurance about the long-term pipeline performance. This project will develop, demonstrate, and validate an in-situ non-destructive inspection method for butt fusion joints in gas distribution plastic pipelines. The inspection system will include a laser based image-recognition system that will automatically generate and interpret digital images of pipe joints and assign them a pass/fail rating, which eliminates operator bias in evaluating joint quality. A Weld Zone Inspection Method (WZIM) is being developed in which local heat is applied to the joint region to relax the residual stresses formed by the original joining operation and reveal the surface condition of the joint. In cases where the joint is not formed under optimal conditions, and the intermolecular forces between contacting surfaces are not strong enough, the relaxation of macromolecules in the surface layer causes the material to pull back, revealing a fusion line. If the joint is sound, the bond line image does not develop. To establish initial feasibility of the approach, welds were performed under standard and nonstandard conditions. These welds were subjected to the WZIM and tensile testing. There appears to be a direct correlation between the WZIM and tensile testing results. Although WZIM appears to be more sensitive than tensile testing can verify, the approach appears valid.

  20. Clevis joint for deployable space structures

    NASA Technical Reports Server (NTRS)

    Rhodes, Marvin D. (Inventor)

    1990-01-01

    This invention relates generally to pin clevis joints, and more particularly, to zero play pin clevis joints for connecting structural members of a deployable space structure. A joint includes a pin, a tang, and a shackle. The pin is tapered at the same angle as the bores extending through the projections of the shackle and the tang. A spring washer biases the tang onto the tapered sidewall of the pin. The invention solves the free play problem associated with deployable space structures by using a tapered pin which is held in tapered holes by the spring washers.

  1. [An endoapparatus for restoration of hip joint].

    PubMed

    Lapinskaia, V S; Gatiatulin, R R; Trubnikov, V I; Velichko, M V; Froliakin, T V; Kovalenko, A E; Froliakina, L A

    2008-01-01

    The possibility of prolonging the anatomic and functional longevity of joints in young patients with coxarthrosis deformans under conditions of long-term unloading using a submersible distraction device is considered. A submersible endoapparatus for restoration of hip joint is described. Its functional capabilities as an unloading device were corroborated by experimental testing. Clinical examples illustrated with X-ray photographs demonstrate the possibility of long-term unloading of the injured joint and postponement of endoprosthesis replacement in young patients by 20-25 years. It is suggested to use the developed method for organ-sparing surgery in young working-age patients.

  2. Collet lock joint for space station truss

    NASA Technical Reports Server (NTRS)

    Wesselski, Clarence J. (Inventor)

    1988-01-01

    A lock joint for a Space Station has a series of struts joined together in a predetermined configuration by node point fittings. The fittings have removeable inserts. The lock joint has an elongated housing connected at one end to a strut. A split-fingered collet is mounted within the housing to insure reciprocal movement. A handle on the housing is connected to the collet for moving the collet into the insert where the fingers of the collet expand to lock the joint to the fitting.

  3. Synovial Lipomatosis of the Glenohumeral Joint

    PubMed Central

    Safran, Ori

    2016-01-01

    Synovial lipomatosis (also known as lipoma arborescens) is a rare and benign lesion affecting synovium-lined cavities. It is characterized by hyperplasia of mature fat tissue in the subsynovial layer. Although the most commonly affected site is the knee joint, rarely additional locations such as tendon sheath and other joints are involved. We present a case of synovial lipomatosis of the glenohumeral joint in a 44-year-old man. The clinical data radiological studies and histopathologic results are described, as well as a review of the current literature. PMID:27563476

  4. Synovial Lipomatosis of the Glenohumeral Joint.

    PubMed

    Beyth, Shaul; Safran, Ori

    2016-01-01

    Synovial lipomatosis (also known as lipoma arborescens) is a rare and benign lesion affecting synovium-lined cavities. It is characterized by hyperplasia of mature fat tissue in the subsynovial layer. Although the most commonly affected site is the knee joint, rarely additional locations such as tendon sheath and other joints are involved. We present a case of synovial lipomatosis of the glenohumeral joint in a 44-year-old man. The clinical data radiological studies and histopathologic results are described, as well as a review of the current literature.

  5. Acromioclavicular joint injury in competitive golfers.

    PubMed

    Mallon, W J; Colosimo, A J

    1995-01-01

    We reviewed a series of professional and competitive low-handicap golfers with shoulder pain. All but one player (34/35) had pain in the left shoulder. A high incidence of problems (53%) related to the acromioclavicular joint was noted in these golfers with left shoulder pain. With proper treatment all but one (17/18 [94%]) of the golfers with acromioclavicular joint problems was able to return to competitive golf. By studying the mechanics of the golf swing, a possible mechanism for this high incidence of acromioclavicular joint problems is given.

  6. Joint fluid cytology in Reiter's disease.

    PubMed Central

    Spriggs, A I; Boddington, M M; Mowat, A G

    1978-01-01

    The diagnostic value of the finding of cytophagocytic macrophages (CPM) in the joint fluid of patients with Reiter's disease has been re-examined. CPM were found in 46% of Reiter's disease fluids and in 45% of other inflammatory knee joint fluids. Higher CPM scores, on a 4-point grading, were commoner in Reiter's disease but the difference was not statistically significant. Further, although the graded polymorphonuclear leucocyte phagocytosis shown by CPM was greater in Reiter's disease this also was not significant. It is concluded that the presence of CPM in joint fluid is of little discriminating value. Images PMID:749702

  7. [An endoapparatus for restoration of hip joint].

    PubMed

    Lapinskaia, V S; Gatiatulin, R R; Trubnikov, V I; Velichko, M V; Froliakin, T V; Kovalenko, A E; Froliakina, L A

    2008-01-01

    The possibility of prolonging the anatomic and functional longevity of joints in young patients with coxarthrosis deformans under conditions of long-term unloading using a submersible distraction device is considered. A submersible endoapparatus for restoration of hip joint is described. Its functional capabilities as an unloading device were corroborated by experimental testing. Clinical examples illustrated with X-ray photographs demonstrate the possibility of long-term unloading of the injured joint and postponement of endoprosthesis replacement in young patients by 20-25 years. It is suggested to use the developed method for organ-sparing surgery in young working-age patients. PMID:18688939

  8. Temporomandibular Joint Dysfunction: A Dental Overview

    PubMed Central

    Hillier, Clyde D.

    1985-01-01

    Temporomandibular joint dysfunction is common and often acutely painful. Because of the large and diverse symptom complex created by this disorder, patients frequently first seek relief from their physician rather than their dentist. In this article temporomandibular joint (TMJ) dysfunction is defined and the presenting signs and symptoms are discussed. Their etiology is described in relation to the anatomy of the temporomandibular joint. Examination techniques can help in the differential diagnosis. Current treatment ranges from heat, local anesthesia and ultrasound to anxiolytics, transcutaneous nerve stimulation and nutritional supplementation. ImagesFig. 1Fig. 2Fig. 3Fig. 4Fig. 5Fig. 6Fig. 7Fig. 8 PMID:21274225

  9. Equine rehabilitation therapy for joint disease.

    PubMed

    Porter, Mimi

    2005-12-01

    The principles of physical rehabilitation therapy can be applied to the horse to provide a reduction in discomfort and dysfunction associated with the various forms of joint disease. Physical agents,such as ice, heat, electricity, sound, light, magnetic fields, compression, and movement, can be used by the rehabilitation therapist to attempt to control pain, reduce swelling, and restore optimal movement and function in the affected joint. The equine therapist's attention is focused not only on the affected joint but on the body as a whole to manage secondary or compensatory problems.

  10. Joint custody: research, theory, and policy.

    PubMed

    Coller, D R

    1988-12-01

    A majority of states have now enacted legislation addressing the issue of joint custody of children after divorce. This article examines current research on the subject, explores its implications for family theory, and attempts to draw some empirically based conclusions regarding policy. The literature would seem to support a structuralist view of the family and to undermine normative theories of the family life cycle. The author concludes that policy should not be aimed at developing a presumption of joint legal custody alone, but, rather, of joint physical custody with specified limitations.

  11. Joint custody: a critical analysis and appraisal.

    PubMed

    Derdeyn, A P; Scott, E

    1984-04-01

    Joint custody, now in the statutes of over half the states, is becoming the legally preferred custody arrangement. It eases the burden on the courts, and is thought to benefit all family members. Research has indicated that children generally gain from maintaining a relationship with each parent; however, the assumption that joint custody promotes cooperation between divorced parents is a research question that has yet to be answered. There is a disparity between the strength of the joint custody movement and the sufficiency of evidence that this is the optimum approach for all children.

  12. How does joint remodeling work?: new insights in the molecular regulation of the architecture of joints.

    PubMed

    Schett, Georg

    2007-01-01

    Remodeling of joints is a key feature of inflammatory and degenerative joint disease. Bone erosion, cartilage degeneration and growth of bony spurs termed osteophytes are key features of structural joint pathology in the course of arthritis, which lead to impairment of joint function. Understanding their molecular mechanisms is essential to tailor targeted therapeutic approaches to protect joint architecture from inflammatory and mechanical stress. This addendum summarizes the new insights in the molecular regulation of bone formation in the joint and its relation to bone resorption. It describes how inflammatory cytokines impair bone formation and block the repair response of joints towards inflammatory stimuli. It particularly points out the key role of Dickkopf-1 protein, a regulator of the Wingless signaling and inhibitor of bone formation. This new link between inflammation and bone formation is also crucial for explaining the generation of osteophytes, bony spurs along joints, which are characterized by new bone and cartilage formation. This mechanism is largely dependent on an activation of wingless protein signaling and can lead to complete joint fusion. This addendum summarized the current concepts of joint remodeling in the limelight of these new findings.

  13. Total joint replacement preadmission programs.

    PubMed

    Messer, B

    1998-01-01

    Patients begin to formulate their expectations of the postoperative hospitalization during the preadmission program. The challenge is to better understand the factors patients consider when formulating judgments about the quality of preadmission education. For example, it may be that perceptions of the preadmission program are influenced by what patients believe about their postoperative pain and functional abilities. Specific attention needs to be given both preoperatively and postoperatively to instructing patients on realistic expectations for recovery. One other method of measuring patient outcomes is with the Health Status Profile (SF-36) (Response Healthcare Information Management, 1995). The SF-36 approach emphasizes the outcome of medical care as the patient sees it, in addition to a clinical evaluation of successful health care. This form is currently initiated in the physician's office and returned for scanning at the preadmission class. The patient then completes another SF-36 at 6 months and every year thereafter to compare measurable outcomes. Patients intending to have elective total joint replacements experience anxiety and require much support and education. An effective preadmission program is a major investment in a patient's recovery, as well as a unique marketing tool to customers. Preadmission programs can be viewed as an opportunity to enhance customer satisfaction. Preadmission clinics are an excellent means for nurses to improve the quality of patient care through patient education. the overall goal of preadmission testing programs is to ensure patient preparedness while increasing quality health care and overall customer satisfaction. To enhance program effectiveness, health care providers must lead collaborative efforts to improve the efficiency of systems. PMID:9601410

  14. Total joint replacement preadmission programs.

    PubMed

    Messer, B

    1998-01-01

    Patients begin to formulate their expectations of the postoperative hospitalization during the preadmission program. The challenge is to better understand the factors patients consider when formulating judgments about the quality of preadmission education. For example, it may be that perceptions of the preadmission program are influenced by what patients believe about their postoperative pain and functional abilities. Specific attention needs to be given both preoperatively and postoperatively to instructing patients on realistic expectations for recovery. One other method of measuring patient outcomes is with the Health Status Profile (SF-36) (Response Healthcare Information Management, 1995). The SF-36 approach emphasizes the outcome of medical care as the patient sees it, in addition to a clinical evaluation of successful health care. This form is currently initiated in the physician's office and returned for scanning at the preadmission class. The patient then completes another SF-36 at 6 months and every year thereafter to compare measurable outcomes. Patients intending to have elective total joint replacements experience anxiety and require much support and education. An effective preadmission program is a major investment in a patient's recovery, as well as a unique marketing tool to customers. Preadmission programs can be viewed as an opportunity to enhance customer satisfaction. Preadmission clinics are an excellent means for nurses to improve the quality of patient care through patient education. the overall goal of preadmission testing programs is to ensure patient preparedness while increasing quality health care and overall customer satisfaction. To enhance program effectiveness, health care providers must lead collaborative efforts to improve the efficiency of systems.

  15. Acupuncture for peripheral joint osteoarthritis

    PubMed Central

    Manheimer, Eric; Cheng, Ke; Linde, Klaus; Lao, Lixing; Yoo, Junghee; Wieland, Susan; van der Windt, Daniëlle AWM; Berman, Brian M; Bouter, Lex M

    2011-01-01

    Background Peripheral joint osteoarthritis is a major cause of pain and functional limitation. Few treatments are safe and effective. Objectives To assess the effects of acupuncture for treating peripheral joint osteoarthritis. Search strategy We searched the Cochrane Central Register of Controlled Trials (The Cochrane Library 2008, Issue 1), MEDLINE, and EMBASE (both through December 2007), and scanned reference lists of articles. Selection criteria Randomized controlled trials (RCTs) comparing needle acupuncture with a sham, another active treatment, or a waiting list control group in people with osteoarthritis of the knee, hip, or hand. Data collection and analysis Two authors independently assessed trial quality and extracted data. We contacted study authors for additional information. We calculated standardized mean differences using the differences in improvements between groups. Main results Sixteen trials involving 3498 people were included. Twelve of the RCTs included only people with OA of the knee, 3 only OA of the hip, and 1 a mix of people with OA of the hip and/or knee. In comparison with a sham control, acupuncture showed statistically significant, short-term improvements in osteoarthritis pain (standardized mean difference -0.28, 95% confidence interval -0.45 to -0.11; 0.9 point greater improvement than sham on 20 point scale; absolute percent change 4.59%; relative percent change 10.32%; 9 trials; 1835 participants) and function (-0.28, -0.46 to -0.09; 2.7 point greater improvement on 68 point scale; absolute percent change 3.97%; relative percent change 8.63%); however, these pooled short-term benefits did not meet our predefined thresholds for clinical relevance (i.e. 1.3 points for pain; 3.57 points for function) and there was substantial statistical heterogeneity. Additionally, restriction to sham-controlled trials using shams judged most likely to adequately blind participants to treatment assignment (which were also the same shams judged most

  16. 21 CFR 26.73 - Joint Committee.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... OF PHARMACEUTICAL GOOD MANUFACTURING PRACTICE REPORTS, MEDICAL DEVICE QUALITY SYSTEM AUDIT REPORTS, AND CERTAIN MEDICAL DEVICE PRODUCT EVALUATION REPORTS: UNITED STATES AND THE EUROPEAN COMMUNITY â... United States and the European Community (EC) will be established. The Joint Committee shall...

  17. Generalized Models for Rock Joint Surface Shapes

    PubMed Central

    Du, Shigui; Hu, Yunjin; Hu, Xiaofei

    2014-01-01

    Generalized models of joint surface shapes are the foundation for mechanism studies on the mechanical effects of rock joint surface shapes. Based on extensive field investigations of rock joint surface shapes, generalized models for three level shapes named macroscopic outline, surface undulating shape, and microcosmic roughness were established through statistical analyses of 20,078 rock joint surface profiles. The relative amplitude of profile curves was used as a borderline for the division of different level shapes. The study results show that the macroscopic outline has three basic features such as planar, arc-shaped, and stepped; the surface undulating shape has three basic features such as planar, undulating, and stepped; and the microcosmic roughness has two basic features such as smooth and rough. PMID:25152901

  18. Tubular lap joints for wind turbine applications

    SciTech Connect

    Reedy, E.D. Jr.; Guess, T.R.

    1990-01-01

    A combined analytical/experimental study of the strength of thick- walled, adhesively bonded PMMA-to-aluminum and E-glass/epoxy composite-to-aluminum tubular lap joints under axial load has been conducted. Test results include strength and failure mode data. Moreover, strain gages placed along the length of the outer tubular adherend characterize load transfer from one adherend to the other. The strain gage data indicate that load transfer is nonuniform and that the relatively compliant PMMA has the shorter load transfer length. Strains determined by a finite element analysis of the tested joints are in excellent agreement with those measured. Calculated bond stresses are highest in the region of observed failure, and extensive bond yielding is predicted in the E- glass/epoxy composite-to-aluminum joint prior to joint failure. 4 refs., 13 figs., 1 tab.

  19. Joint Genome Institute's Automation Approach and History

    SciTech Connect

    Roberts, Simon

    2006-07-05

    Department of Energy/Joint Genome Institute (DOE/JGI) collaborates with DOE national laboratories and community users, to advance genome science in support of the DOE missions of clean bio-energy, carbon cycling, and bioremediation.

  20. Joint Actinide Shock Physics Experimental Research - JASPER

    ScienceCinema

    None

    2016-07-12

    Commonly known as JASPER the Joint Actinide Shock Physics Experimental Research facility is a two stage light gas gun used to study the behavior of plutonium and other materials under high pressures, temperatures, and strain rates.

  1. Functionally Graded Adhesives for Composite Joints

    NASA Technical Reports Server (NTRS)

    Stapleton, Scott E.; Waas, Anthony M.; Arnold, Steven M.

    2012-01-01

    Adhesives with functionally graded material properties are being considered for use in adhesively bonded joints to reduce the peel stress concentrations located near adherend discontinuities. Several practical concerns impede the actual use of such adhesives. These include increased manufacturing complications, alterations to the grading due to adhesive flow during manufacturing, and whether changing the loading conditions significantly impact the effectiveness of the grading. An analytical study is conducted to address these three concerns. An enhanced joint finite element, which uses an analytical formulation to obtain exact shape functions, is used to model the joint. Furthermore, proof of concept testing is conducted to show the potential advantages of functionally graded adhesives. In this study, grading is achieved by strategically placing glass beads within the adhesive layer at different densities along the joint.

  2. Joint Detect and Avoid Flight Testing

    NASA Technical Reports Server (NTRS)

    Maliska, Heather; Estrada, Ramon; Euteneuer, Eric; Gong, Chester; Arthur, Keith

    2015-01-01

    This presentation gives insight into a joint flight testing effort that included participation from NASA, Honeywell, and General Atomics. The presentation includes roles and responsibilities, test flow, and encounter requirements and summary.

  3. Joint enhancement of multichannel SAR data

    NASA Astrophysics Data System (ADS)

    Ramakrishnan, Naveen; Ertin, Emre; Moses, Randolph L.

    2007-04-01

    In this paper we consider the problem of joint enhancement of multichannel Synthetic Aperture Radar (SAR) data. Previous work by Cetin and Karl introduced nonquadratic regularization methods for image enhancement using sparsity enforcing penalty terms. For multichannel data, independent enhancement of each channel is shown to degrade the relative phase information across channels that is useful for 3D reconstruction. We thus propose a method for joint enhancement of multichannel SAR data with joint sparsity constraints. We develop both a gradient-based and a Lagrange-Newton-based method for solving the joint reconstruction problem, and demonstrate the performance of the proposed methods on IFSAR height extraction problem from multi-elevation data.

  4. Joint Actinide Shock Physics Experimental Research - JASPER

    SciTech Connect

    2014-10-31

    Commonly known as JASPER the Joint Actinide Shock Physics Experimental Research facility is a two stage light gas gun used to study the behavior of plutonium and other materials under high pressures, temperatures, and strain rates.

  5. Failure analyses of composite bolted joints

    NASA Technical Reports Server (NTRS)

    Wilson, D. W.; Gillespie, J. W.; York, J. L.; Pipes, R. B.

    1980-01-01

    The complex failure behavior exhibited by bolted joints of graphite epoxy (Hercules AS/3501) was investigated for the net tension, bearing and shearout failure modes using combined analytical and experimental techniques. Plane stress, linear elastic, finite element methods were employed to determine the two dimensional state of stress resulting from a loaded hole in a finite width, semiinfinite strip. The stresses predicted by the finite element method were verified by experiment to lend credence to the analysis. The influence of joint geometric parameters on the state of stress and resultant strength of the joint was also studied. The resulting functional relationships found to exist between bolted joint strength and the geometric parameters, were applied in the formulation of semiempirical strength models for the basic failure modes. A point stress failure criterion was successfully applied as the failure criterion for the net tension and shearout failure modes.

  6. 38 CFR 4.66 - Sacroiliac joint.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... in this location are decrease or obliteration of the joint space, with the appearance of increased... from erector spinae spasm (not accounted for by other pathology), tenderness on deep palpation...

  7. 38 CFR 4.66 - Sacroiliac joint.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... in this location are decrease or obliteration of the joint space, with the appearance of increased... from erector spinae spasm (not accounted for by other pathology), tenderness on deep palpation...

  8. 38 CFR 4.66 - Sacroiliac joint.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... in this location are decrease or obliteration of the joint space, with the appearance of increased... from erector spinae spasm (not accounted for by other pathology), tenderness on deep palpation...

  9. 38 CFR 4.66 - Sacroiliac joint.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... in this location are decrease or obliteration of the joint space, with the appearance of increased... from erector spinae spasm (not accounted for by other pathology), tenderness on deep palpation...

  10. Structural dynamic analysis of a ball joint

    NASA Astrophysics Data System (ADS)

    Hwang, Seok-Cheol; Lee, Kwon-Hee

    2012-11-01

    Ball joint is a rotating and swiveling element that is typically installed at the interface between two parts. In an automobile, the ball joint is the component that connects the control arms to the steering knuckle. The ball joint can also be installed in linkage systems for motion control applications. This paper describes the simulation strategy for a ball joint analysis, considering manufacturing process. Its manufacturing process can be divided into plugging and spinning. Then, the interested responses is selected as the stress distribution generated between its ball and bearing. In this paper, a commercial code of NX DAFUL using an implicit integration method is introduced to calculate the response. In addition, the gap analysis is performed to investigate the fitness, focusing on the response of the displacement of a ball stud. Also, the optimum design is suggested through case studies.

  11. Irish National Joint Registry: a concept.

    PubMed

    Oduwole, K O; Codd, M B; Byrne, F; O'Byrne, J; Kenny, P J

    2008-12-01

    Despite the well-documented benefits, some countries have yet to agree on the establishment of a national joint register. A questionnaire study was undertaken to ascertain the opinions of the consultant orthopaedic surgeons and specialist registrars, regarding establishment of an Irish National Joint Register. The aim was to find out the possible reasons why a national joint register has not been established in Ireland. A 69% first response rate was recorded. Ninety-seven percent believe it is time to set up a registry and 81% say it should be made compulsory for unwilling surgeons and hospitals to participate. Despite the overwhelming support, privacy and liability issues were major concerns. Fifty-eight percent agree that access to registry report by general public can expose surgeons and hospitals to medico-legal implications. Legislation may be required to protect the integrity of a national joint replacement registry to ensure that the data are used as intended.

  12. First metatarsophalangeal joint arthrodesis: current fixation options.

    PubMed

    Moon, Jared L; McGlamry, Michael C

    2011-04-01

    This article reviews the current literature on first metatarsophalangeal joint arthrodesis rates using various forms of fixation, as well as reviewing biomechanical studies comparing the strengths of the different fixation options that are available.

  13. Generalized models for rock joint surface shapes.

    PubMed

    Du, Shigui; Hu, Yunjin; Hu, Xiaofei

    2014-01-01

    Generalized models of joint surface shapes are the foundation for mechanism studies on the mechanical effects of rock joint surface shapes. Based on extensive field investigations of rock joint surface shapes, generalized models for three level shapes named macroscopic outline, surface undulating shape, and microcosmic roughness were established through statistical analyses of 20,078 rock joint surface profiles. The relative amplitude of profile curves was used as a borderline for the division of different level shapes. The study results show that the macroscopic outline has three basic features such as planar, arc-shaped, and stepped; the surface undulating shape has three basic features such as planar, undulating, and stepped; and the microcosmic roughness has two basic features such as smooth and rough.

  14. Nanoparticles Ease Aching Joints in Mice

    MedlinePlus

    ... page: https://medlineplus.gov/news/fullstory_161188.html Nanoparticles Ease Aching Joints in Mice Treatment might one ... News) -- New research in mice suggests that tiny nanoparticles might one day be a better way to ...

  15. Control of Compliant Anthropomimetic Robot Joint

    NASA Astrophysics Data System (ADS)

    Potkonjak, Veljko; Svetozarevic, Bratislav; Jovanovic, Kosta; Holland, Owen

    2010-09-01

    In this paper we propose a control strategy for a robot joint which fully mimics the typical human joint structure. The joint drive is based on two actuators (dc motors), agonist and antagonist, acting through compliant tendons and forming a nonlinear multi-input multi-output (MIMO) system. At any time, we consider one actuator, the puller, as being responsible for motion control, while the role of the other is to keep its tendon force at some appropriate low level. This human-like and energetically efficient approach requires the control of "switching", or exchanging roles between actuators. Moreover, an algorithm based on adaptive force reference is used to solve a problem of slacken tendons during the switching and to increase the energy efficiency. This approach was developed and evaluated on increasingly complex robot joint configurations, starting with linear and noncompliant system, and finishing with nonlinear and compliant system.

  16. The effects of taping, stretching, and joint exercise on hip joint flexibility and range of motion

    PubMed Central

    Choi, Jung-Hyun; Yoo, Kyung-Tae; An, Ho-Jung; Choi, Wan-Suk; Koo, Ja-Pung; Kim, Jae-Ic; Kim, Nyeon-Jun

    2016-01-01

    [Purpose] This study aimed to examine the effects of joint exercise, taping, and stretching on hip joint flexion, flexibility, and range of motion. [Subjects and Methods] Forty-five college students in their 20s were randomly assigned and equally divided into three groups, as follows: a stretching group, a taping and exercise group, and an exercise group. Changes in trunk range of motion and hip joint flexibility of the three groups were measured before and after the intervention. [Results] Comparison between flexibility before and after the intervention revealed statistically significant changes in all three groups. Moreover, the evaluation of joint range of motion after the intervention showed that there were statistically significant changes in all three groups. [Conclusion] Taping, stretching, and joint exercise are considered effective for the increase in flexibility and joint range of motion. PMID:27313394

  17. Osteoma of temporomandibular joint: a rarity.

    PubMed

    Misra, Neeta; Srivastava, Saurabh; Bodade, Pankaj R; Rastogi, Vikalp

    2013-09-06

    Osteoma is a benign tumour consisting of mature bone tissue. It is an uncommon lesion that occurs in the bones of the craniofacial complex. Only a few cases involving the temporomandibular joint have been reported. An osteoma of the left temporomandibular joint causing limited mouth opening in a 22-year-old man with CT findings revealing the unusual possibility in differential diagnosis of trismus.

  18. Osteoma of temporomandibular joint: a rarity

    PubMed Central

    Misra, Neeta; Srivastava, Saurabh; Bodade, Pankaj R; Rastogi, Vikalp

    2013-01-01

    Osteoma is a benign tumour consisting of mature bone tissue. It is an uncommon lesion that occurs in the bones of the craniofacial complex. Only a few cases involving the temporomandibular joint have been reported. An osteoma of the left temporomandibular joint causing limited mouth opening in a 22-year-old man with CT findings revealing the unusual possibility in differential diagnosis of trismus. PMID:24014334

  19. Joint transform correlator employing electron trapping materials

    NASA Astrophysics Data System (ADS)

    Yu, Dong X.; Storti, George M.; Gregory, Don A.

    1992-07-01

    Quantex's electron trapping (ET) materials are investigated as an integrated spatial light modulator (SLM) at the filter plane in a joint transform correlator (JTC). The ET based spatial light modulator can detect visible incoherent light, store an image pattern, and modulate the incoming coherent infrared light. Such a JTC architecture eliminates the electronic-to-optical and optical-to-electronic conversion between the square law detector and the next SLM in a joint transform correlator.

  20. Kinematics of Hooke universal joint robot wrists

    NASA Technical Reports Server (NTRS)

    Mckinney, William S., Jr.

    1988-01-01

    The singularity problem associated with wrist mechanisms commonly found on industrial manipulators can be alleviated by redesigning the wrist so that it functions as a three-axis gimbal system. This paper discussess the kinematics of gimbal robot wrists made of one and two Hooke universal joints. Derivations of the resolved rate motion control equations for the single and double Hooke universal joint wrists are presented using the three-axis gimbal system as a theoretical wrist model.

  1. Wormhole Formation in RSRM Nozzle Joint Backfill

    NASA Technical Reports Server (NTRS)

    Stevens, J.

    2000-01-01

    The RSRM nozzle uses a barrier of RTV rubber upstream of the nozzle O-ring seals. Post flight inspection of the RSRM nozzle continues to reveal occurrence of "wormholes" into the RTV backfill. The term "wormholes", sometimes called "gas paths", indicates a gas flow path not caused by pre-existing voids, but by a little-understood internal failure mode of the material during motor operation. Fundamental understanding of the mechanics of the RSRM nozzle joints during motor operation, nonlinear viscoelastic characterization of the RTV backfill material, identification of the conditions that predispose the RTV to form wormholes, and screening of candidate replacement materials is being pursued by a joint effort between Thiokol Propulsion, NASA, and the Army Propulsion & Structures Directorate at Redstone Arsenal. The performance of the RTV backfill in the joint is controlled by the joint environment. Joint movement, which applies a tension and shear load on the material, coupled with the introduction of high pressure gas in combination create an environment that exceeds the capability of the material to withstand the wormhole effect. Little data exists to evaluate why the material fails under the modeled joint conditions, so an effort to characterize and evaluate the material under these conditions was undertaken. Viscoelastic property data from characterization testing will anchor structural analysis models. Data over a range of temperatures, environmental pressures, and strain rates was used to develop a nonlinear viscoelastic model to predict material performance, develop criteria for replacement materials, and quantify material properties influencing wormhole growth. Three joint simulation analogs were developed to analyze and validate joint thermal barrier (backfill) material performance. Two exploratory tests focus on detection of wormhole failure under specific motor operating conditions. A "validation" test system provides data to "validate" computer models and

  2. Interventional radiology in bone and joint

    SciTech Connect

    Bard, M.; Laredo, J.D.

    1988-01-01

    Recent radiologic procedures in bone and joints, some of which eliminate the need for surgery are exposed, including: trephine biopsies of the thoracic and lumbar spine, sacro-iliac joints, peripheral bones synovial membrane and soft tissues, using either fluoroscopic echographic or CT guidance - chemonucleolysis - vascular embolization of skeletal tumors and management of vertebral hemangiomas - selective steroid injection in a broad spectrum of diseases including vertebral facet syndrome, cervicobrachial nerve root pain, rotator cuff calcium deposit, bone cysts.

  3. Low-Friction Joint for Robot Fingers

    NASA Technical Reports Server (NTRS)

    Ruoff, C. F.

    1985-01-01

    Mechanical linkage allows adjacent parts to move relative to each other with low friction and with no chatter, slipping, or backlash. Low-friction joint of two surfaces in rolling contact, held in alinement by taut flexible bands. No sliding friction or "stick-slip" motion: Only rolling-contact and bending friction within bands. Proposed linkage intended for finger joints in mechanical hands for robots and manipulators.

  4. Rotational joint assembly for the prosthetic leg

    NASA Technical Reports Server (NTRS)

    Owens, L. J.; Jones, W. C. (Inventor)

    1977-01-01

    A rotational joint assembly for a prosthetic leg has been devised, which enables an artificial foot to rotate slightly when a person is walking, running or turning. The prosthetic leg includes upper and lower tubular members with the rotational joint assembly interposed between them. The assembly includes a restrainer mechanism which consists of a pivotably mounted paddle element. This device applies limiting force to control the rotation of the foot and also restores torque to return the foot back to its initial position.

  5. CHARACTERIZATION OF DAMPING IN BOLTED LAP JOINTS

    SciTech Connect

    C. MALONEY; D. PEAIRS; ET AL

    2000-08-01

    The dynamic response of a jointed beam was measured in laboratory experiments. The data were analyzed and the system was mathematically modeled to establish plausible representations of joint damping behavior. Damping is examined in an approximate, local linear framework using log decrement and half power bandwidth approaches. in addition, damping is modeled in a nonlinear framework using a hybrid surface irregularities model that employs a bristles-construct. Experimental and analytical results are presented.

  6. Joint Disorders - Multiple Languages: MedlinePlus

    MedlinePlus

    ... عقباستبدال المفصل بالكامل - العربية Bilingual PDF Health Information Translations Bosnian (Bosanski) Home Care After Total Joint Replacement ... zamjene zgloba - Bosanski (Bosnian) Bilingual PDF Health Information Translations Chinese - Simplified (简体中文) Home Care After Total Joint ...

  7. Ceramic joint interface diagnostics with ultrasonic reflection signal energies

    SciTech Connect

    Telschow, K.L.; Walter, J.B.

    1988-07-01

    The properties of silicon nitride ceramic joints, prepared by hot isostatic pressing, have been investigated by recording the reflected ultrasonic elastic wave off the joint interface. Experimental and theoretical analysis of the reflected signal energy has shown that properties of the joint interface such as thickness, joining compound composition, inclusions, and voids, can be imaged over the joint plane. A model incorporating plane waves shows that the reflected signal energy is a function of joint thickness, joint/host acoustic impedence and transducer bandwidth. For joint thicknesses less than the average ultrasonic wavelength in the joint, the reflected signal energy depends quadratically on the thickness. This dependence was verified by for several joints by direct measurement. In the opposite regime, where the joint thickness is greater than the ultrasonic wavelength, the reflected signal energy is independent of thickness and only a function of the joint/host acoustic impedence mismatch. This regime was not accessible with the bandwidth transducers. The results suggest that for a given range of thicknesses, measurement of the joint energy with broadband transducers with different center frequencies could provide a means of determining both the joint thickness and joint/host acoustic impedence mismatch. Joint thickness is the most prominent parameter that can be probed with ultrasonics and its effect on fracture toughness should be an important parameter in determining the quality of joints. Qualitatively, the reflected signal energy method of data analysis is a rapid means for assessing joint quality with respect to thickness, inclusions, and voids.

  8. A study of sandwich T-joints and composite lap joints

    NASA Astrophysics Data System (ADS)

    Turaga, Umamaheswar V. R. S.

    In this study, new efficient designs for adhesive sandwich T-joint and single-lap joint were proposed and investigated. In the proposed new sandwich T-joint, called U-channel joint, the load transfer path at the web-flange interface was modified to include a U-shaped aluminum channel which provides strong path for load transfer. Experimental results show that the new design has 62% more strength than the conventional circular fillet joint. The new U-channel joint was tested in tension, compression and bending to investigate its characteristics. It is found to have good performance in bending also, even though in compression it performs same as the circular fillet joint. An extensive parametric study was carried out to investigate the effect of parameters like flange skin stiffener, foam density, foam thickness in the web, and aluminum attachments. A fracture mechanics criterion based on the strain energy release rate was used to explain the failure modes, apart from the stress analysis explanation. The failure loads of the joints in compression were predicted using a maximum principal stress failure criterion based on the sandwich beam theory. A new single lap joint with attachments was proposed in the second phase of the research. The design was verified using both aluminum and composite materials. The new design was found to have 59% more strength than the single-lap joint. A parametric study was performed to find out the influence of the angle of attachment, thickness of attachment and the length of attachment. By careful consideration of design parameters, the joint can be optimized. Finally, the failure loads of the single lap joints with and without attachments were predicted using different failure criteria.

  9. Nonlinear transient analysis of joint dominated structures

    NASA Technical Reports Server (NTRS)

    Chapman, J. M.; Shaw, F. H.; Russell, W. C.

    1987-01-01

    A residual force technique is presented that can perform the transient analyses of large, flexible, and joint dominated structures. The technique permits substantial size reduction in the number of degrees of freedom describing the nonlinear structural models and can account for such nonlinear joint phenomena as free-play and hysteresis. In general, joints can have arbitrary force-state map representations but these are used in the form of residual force maps. One essential feature of the technique is to replace the arbitrary force-state maps describing the nonlinear joints with residual force maps describing the truss links. The main advantage of this replacement is that the incrementally small relative displacements and velocities across a joint are not monitored directly thereby avoiding numerical difficulties. Instead, very small and 'soft' residual forces are defined giving a numerically attractive form for the equations of motion and thereby permitting numerically stable integration algorithms. The technique was successfully applied to the transient analyses of a large 58 bay, 60 meter truss having nonlinear joints. A method to perform link testing is also presented.

  10. Evaluation and treatment of acromioclavicular joint injuries.

    PubMed

    Mazzocca, Augustus D; Arciero, Robert A; Bicos, James

    2007-02-01

    Acromioclavicular joint injuries and, more specifically, separations are commonplace both in general practice and during athletic participation. This article reviews the traditional classification as well as the clinical evaluation of patients with acute and chronic acromioclavicular joint separations. It also highlights many recent advances, principally in the anatomy and biomechanics of the acromioclavicular joint ligamentous complex. The concept of increases in superior translation as well as disturbances in horizontal translation with injuries to this joint and ligaments are discussed. This information, coupled with the unpredictable long-term results with the Weaver-Dunn procedure and its modifications, have prompted many recent biomechanical studies evaluating potential improvements in the surgical management of acute and chronic injuries. The authors present these recent works investigating cyclic loading and ultimate failure of traditional reconstructions, augmentations, use of free graft, and the more recent anatomic reconstruction of the conoid and trapezoid ligaments. The clinical results (largely retrospective), including acromioclavicular joint repair, reconstruction and augmentation with the coracoclavicular ligament, supplemental sutures, and the use of free autogenous grafts, are summarized. Finally, complications and the concept of the failed distal clavicle resection and reconstruction are addressed. The intent is to provide a current, in-depth treatise on all aspects of acromioclavicular joint complex injuries to include anatomy, biomechanics, benchmark studies on instability and reconstruction, clinical and radiographic evaluation, and to present the most recent clinical research on surgical outcomes.

  11. Cryotherapy impairs knee joint position sense.

    PubMed

    Oliveira, R; Ribeiro, F; Oliveira, J

    2010-03-01

    The effects of cryotherapy on joint position sense are not clearly established; however it is paramount to understand its impact on peripheral feedback to ascertain the safety of using ice therapy before resuming exercise on sports or rehabilitation settings. Thus, the aim of the present study was to determine the effects of cryotherapy, when applied over the quadriceps and over the knee joint, on knee position sense. This within-subjects repeated-measures study encompassed fifteen subjects. Knee position sense was measured by open kinetic chain technique and active positioning at baseline and after cryotherapy application. Knee angles were determined by computer analysis of the videotape images. Twenty-minute ice bag application was applied randomly, in two sessions 48 h apart, over the quadriceps and the knee joint. The main effect for cryotherapy application was significant (F (1.14)=7.7, p=0.015) indicating an increase in both absolute and relative angular errors after the application. There was no significant main effect for the location of cryotherapy application, indicating no differences between the application over the quadriceps and the knee joint. In conclusion, cryotherapy impairs knee joint position sense in normal knees. This deleterious effect is similar when cryotherapy is applied over the quadriceps or the knee joint.

  12. Experimental characterization of deployable trusses and joints

    NASA Technical Reports Server (NTRS)

    Ikegami, R.; Church, S. M.; Keinholz, D. A.; Fowler, B. L.

    1987-01-01

    The structural dynamic properties of trusses are strongly affected by the characteristics of joints connecting the individual beam elements. Joints are particularly significant in that they are often the source of nonlinearities and energy dissipation. While the joints themselves may be physically simple, direct measurement is often necessary to obtain a mathematical description suitable for inclusion in a system model. Force state mapping is a flexible, practical test method for obtaining such a description, particularly when significant nonlinear effects are present. It involves measurement of the relationship, nonlinear or linear, between force transmitted through a joint and the relative displacement and velocity across it. An apparatus and procedure for force state mapping are described. Results are presented from tests of joints used in a lightweight, composite, deployable truss built by the Boeing Aerospace Company. The results from the joint tests are used to develop a model of a full 4-bay truss segment. The truss segment was statically and dynamically tested. The results of the truss tests are presented and compared with the analytical predictions from the model.

  13. Cryotherapy impairs knee joint position sense.

    PubMed

    Oliveira, R; Ribeiro, F; Oliveira, J

    2010-03-01

    The effects of cryotherapy on joint position sense are not clearly established; however it is paramount to understand its impact on peripheral feedback to ascertain the safety of using ice therapy before resuming exercise on sports or rehabilitation settings. Thus, the aim of the present study was to determine the effects of cryotherapy, when applied over the quadriceps and over the knee joint, on knee position sense. This within-subjects repeated-measures study encompassed fifteen subjects. Knee position sense was measured by open kinetic chain technique and active positioning at baseline and after cryotherapy application. Knee angles were determined by computer analysis of the videotape images. Twenty-minute ice bag application was applied randomly, in two sessions 48 h apart, over the quadriceps and the knee joint. The main effect for cryotherapy application was significant (F (1.14)=7.7, p=0.015) indicating an increase in both absolute and relative angular errors after the application. There was no significant main effect for the location of cryotherapy application, indicating no differences between the application over the quadriceps and the knee joint. In conclusion, cryotherapy impairs knee joint position sense in normal knees. This deleterious effect is similar when cryotherapy is applied over the quadriceps or the knee joint. PMID:20221997

  14. Joint attention, shared goals and social bonding

    PubMed Central

    Wolf, Wouter; Launay, Jacques; Dunbar, Robin I. M.

    2016-01-01

    There has recently been interest in the ways in which coordinated movements encourage coactors to feel social closer to one another, but this has generally overlooked the importance of necessary precursors to this joint action. Here we target two low-level behaviours involved in social coordination that may mediate a relationship between joint actions and social bonding, namely joint attention and shared goals. Participants engaged in a simple reaction time task whilst sitting next to a partner performing the same task. In a joint attention condition both participants attended to stimuli presented on the same half of a computer screen, while in a control condition they attended to opposite sides of the computer screen. Shared goals were manipulated by giving participants the instruction to keep below a threshold score for both individual response times and accuracy (individual goal), or their joint mean response time and accuracy (i.e. averaging their mean response time and accuracy with that of their partner: shared goal). Attending to the same side of the screen led to higher ratings on a composite social bonding index directed towards a partner, while shared goals did not cause any significant effects on partner ratings. Joint attention was sufficient to encourage social closeness with an interaction partner, which suggests that any activities which encourage attending to the same point in space could have some influence on how connected co-actors feel about one another. PMID:26256821

  15. Joint hypermobility leading to osteoarthrosis and chondrocalcinosis.

    PubMed

    Bird, H A; Tribe, C R; Bacon, P A

    1978-06-01

    We have reviewed 21 adults referred to rheumatology clinic and considered to have generalised joint hypermobility by the criteria of Carter and Wilkinson (1964), modified by Beighton et al. (1973). They fell into two categories. 5 patients had a raised plasma viscosity (PV) and in each case a definite pathology was found to account for this, superimposed on hypermobile joints. The remaining 16 had a normal PV and this group was thought to represent the late natural history of hypermobility. 5 of these (aged 32 to 54 years) had no evidence of osteoarthrosis but the remaining 11 (aged 34 to 80 years) had widespread radiological osteoarthrosis. Synovial histology was obtained at arthroscopy in 6 of these patients and 4 (aged 60 to 75) had chondrocalcinosis. This previously undescribed finding may be the end result of hypermobile joints. Hypermobile patients with joint deformity (lax connective tissue), widespread synovial thickening (traumatic), and hot joint effusions (chondrocalcinosis) may mimic rheumatoid arthritis. They must be distinguished from patients who develop rheumatoid arthritis in hypermobile joints.

  16. Chronic sprains of the carpometacarpal joints.

    PubMed

    Joseph, R B; Linscheid, R L; Dobyns, J H; Bryan, R S

    1981-03-01

    The relatively rigid second and third carpometacarpal joints provide stability for the cantilevered metacarpals of the index and middle fingers, about which the thumb and ulnar metacarpals move, providing spatial adaptation for grasping objects. Although seldom recognized, sprains of the carpometacarpal joints as part of a range of injury which includes subluxations, dislocations, and fractures are apparently common. The entity known as carpe bossu also may be related. The second and third carpometacarpal joints are more susceptible to injury in palmar flexion than in dorsiflexion. The sprain may be acute or chronic. Severe swelling over the carpometacarpal area, with tenderness and weakness without significant roentgenographic findings, is suggestive of the acute sprain, which generally responds to immobilization. The chronic sprain is often overlooked or misdiagnosed. Point tenderness of one or more carpometacarpal joints, a palpable laxity, and crepitus with manipulation are seen as physical findings, in decreasing order of frequency. Lidocaine, 0.5 ml, injected directly into the joint offers dramatic relief. If conservative measures are insufficient, arthrodesis of the joint is relatively simple, symptomatically reliable, and functionally uncompromising, especially of the second and third rays.

  17. Determination of representative dimension parameter values of Korean knee joints for knee joint implant design.

    PubMed

    Kwak, Dai Soon; Tao, Quang Bang; Todo, Mitsugu; Jeon, Insu

    2012-05-01

    Knee joint implants developed by western companies have been imported to Korea and used for Korean patients. However, many clinical problems occur in knee joints of Korean patients after total knee joint replacement owing to the geometric mismatch between the western implants and Korean knee joint structures. To solve these problems, a method to determine the representative dimension parameter values of Korean knee joints is introduced to aid in the design of knee joint implants appropriate for Korean patients. Measurements of the dimension parameters of 88 male Korean knee joint subjects were carried out. The distribution of the subjects versus each measured parameter value was investigated. The measured dimension parameter values of each parameter were grouped by suitable intervals called the "size group," and average values of the size groups were calculated. The knee joint subjects were grouped as the "patient group" based on "size group numbers" of each parameter. From the iterative calculations to decrease the errors between the average dimension parameter values of each "patient group" and the dimension parameter values of the subjects, the average dimension parameter values that give less than the error criterion were determined to be the representative dimension parameter values for designing knee joint implants for Korean patients.

  18. Experimental joint immobilization in guinea pigs. Effects on the knee joint

    NASA Technical Reports Server (NTRS)

    Marcondesdesouza, J. P.; Machado, F. F.; Sesso, A.; Valeri, V.

    1980-01-01

    In young and adult guinea pigs, the aftermath experimentally induced by the immobilization of the knee joint in hyperextended forced position was studied. Joint immobilization which varied from one to nine weeks was attained by plaster. Eighty knee joints were examined macro and microscopically. Findings included: (1) muscular hypotrophy and joint stiffness in all animals, directly proportional to the length of immobilization; (2) haemoarthrosis in the first week; (3) intra-articular fibrous tissue proliferation ending up with fibrous ankylosis; (4) hyaline articular cartilage erosions; (5) various degrees of destructive menisci changes. A tentative explanation of the fibrous tissue proliferation and of the cartilage changes is offered.

  19. The joints of the evolving foot. Part I. The ankle joint.

    PubMed Central

    Lewis, O J

    1980-01-01

    Evidence is presented to suggest that the eutherian ankle joint has been derived from a meniscus-containing joint such as that found in extant arboreal marsupials. Probable morphological derivatives of this meniscus are identifiable in the Eutheria. The form and function of the joint are described in sub-human Primates and the adaptations which characterize the joint in bipedal man are noted. These morphological findings permit some speculation about the palaeocology of the earliest mammals with particular reference to the emergence of the order Primates. PMID:7410197

  20. [Biomechanics of the knee joint].

    PubMed

    Witzel, U

    1993-01-01

    The capsular and ligamentous structures as control system of a healthy knee-joint supported by the muscular system are responsible for the rolling and gliding motion of the femoral condyles on the tibial plateau. Both the condyles and the tibial plateau have individually developed but to each other adjusted shapes and fine structures thereby. These structures consist of hyaline cartilage at their three-dimensional surfaces and of closely packed fibrils (lamina splendens) as the final gliding zone for tensile load. The orientation of the collagenous fibres can be made visible by split lines. The chondral surfaces are indirectly in contact to each other and orthogonally stressed at the particular point of contact. The indirect contact of the cartilaginous surfaces happens under interposition of the menisci. The meniscus serves to reduce and equalize the surface pressure by its own projected surface on the one hand and by maintaining of a hydraulic pressure of the synovial fluid on the other hand. Deviations of the condylar position as a result on ligamentous instabilities or ruptures with a following occurring loss of congruence, meniscal lesions or traumatic ruptures lead to a rapid discharge of the synovial fluid under load. The result is a hydraulic head loss with direct contact of the chondral surfaces under stress leading to arthrotic deformations. Severe arthrotic deformations or very much every meniscectomy produce intraarticular lumped loads resulting in a hyper-physiologic chondral pressure and malnutrition thereby. Further on there develop subchondral stress concentrations (caused by the lumped loads) leading to osseous damages, too. MR-pictures can make visible these damages. Chondromalacia, fissure or even chondrolysis are arthroscopically detectable sometimes. As after-effects of deficient knee ligaments occur pathological deviations of the femoral condyles and resulting destructions of the articular surfaces under stress enormously intensified by