Sample records for ab eia label

  1. Seroprevalence occurrence of viral hepatitis and HIV among hemodialysis patients.

    PubMed

    Kamal, Inass Mahmood Abid; Mahdi, Batool Mutar

    2018-05-01

    Patients with chronic renal failure (CRF) were on maintenance invasive hemodialysis (HD) procedure. This procedure by itself affects immunity of the patients and became more susceptible to viral infections. to investigate the occurrence of HBV, HCV and HIV infections in patients with hemodialysis. A retrospective study of 430 end-stage renal failure patients, referred to hemodialysis department at XXXX Teaching Hospital, Baghdad-Iraq from January-2015 to January-2017. Patients were investigated for HBs-Ag using enzyme-labeled antigen test (Foresight-EIA-USA), HCV- Abs (IgG) specific immunoglobulin using an HCV enzyme-labeled antigen test (Foresight-EIA-USA)and anti - HIV Abs (IgG) using enzyme-labeled antigen test (Foresight-EIA-USA). The frequency of HBV infection in the first year was not significant between males (1.11%) and females (0.00%) (P = 0.295). About HCV also there are no significant differences between males (12.63%) and females (9.31%) (P = 0.347). After one year of follow up the frequencies of HBV and HCV were not significant between two sexes. Additionally, no any one of the patients had HIV infection. This study brings a light on that HBV and HCV were having the same frequencies in both genders and lower occurrence with time. Furthermore, HIV was not detected in those patients.

  2. Seroprevalence occurrence of viral hepatitis and HIV among hemodialysis patients

    NASA Astrophysics Data System (ADS)

    Kamal, Inass Mahmood; Mutar Mahdi, Batool

    2018-05-01

    Background: Patients with chronic renal failure (CRF) were on maintenance invasive haemodialysis (HD) procedure. This procedure by itself affects immunity of the patients and became more susceptible to viral infections. Aim of the study: to investigate the occurrence of HBV, HCV and HIV infections in patients with hemodialysis. Patients and methods: A retrospective study of 430 end-stage renal failure patients, referred to hemodialysis department at Al-Kindy Teaching Hospital, Baghdad-Iraq from Junuary-2015 to Junuary-2017. Patients were investigated for HBs-Ag using enzyme-labeled antigen test (Foresight-EIA-USA ), HCV- Abs (IgG) specific immunoglobulin using a HCV enzyme-labeled antigen test (Foresight-EIA-USA) and anti HIV Abs (IgG) using enzyme-labeled antigen test (Foresight-EIA-USA). Results: The frequency of HBV infection in the first year was not significant between males (1.11%) and females (0.00%)(P = 0.295). About HCV also there are no significant differences between males (12.63%) and females (9.31%)(P = 0.347). After one year of follow up the frequencies of HBV and HCV were not significant between two sexes. Additionally, no any one of the patients had HIV infection. Conclusions: This study brings a light on that HBV and HCV were having the same frequencies in both genders and lower occurrence with time. Furthermore, HIV was not detected in those patients.

  3. Performance comparison of the 4th generation Bio-Rad Laboratories GS HIV Combo Ag/Ab EIA on the EVOLIS™ automated system versus Abbott ARCHITECT HIV Ag/Ab Combo, Ortho Anti-HIV 1+2 EIA on Vitros ECi and Siemens HIV-1/O/2 enhanced on Advia Centaur.

    PubMed

    Mitchell, Elizabeth O; Stewart, Greg; Bajzik, Olivier; Ferret, Mathieu; Bentsen, Christopher; Shriver, M Kathleen

    2013-12-01

    A multisite study was conducted to evaluate the performance of the Bio-Rad 4th generation GS HIV Combo Ag/Ab EIA versus Abbott 4th generation ARCHITECT HIV Ag/Ab Combo. The performance of two 3rd generation EIAs, Ortho Diagnostics Anti-HIV 1+2 EIA and Siemens HIV 1/O/2 was also evaluated. Study objective was comparison of analytical HIV-1 p24 antigen detection, sensitivity in HIV-1 seroconversion panels, specificity in blood donors and two HIV false reactive panels. Analytical sensitivity was evaluated with International HIV-1 p24 antigen standards, the AFFSAPS (pg/mL) and WHO 90/636 (IU/mL) standards; sensitivity in acute infection was compared on 55 seroconversion samples, and specificity was evaluated on 1000 negative blood donors and two false reactive panels. GS HIV Combo Ag/Ab demonstrated better analytical HIV antigen sensitivity compared to ARCHITECT HIV Ag/Ab Combo: 0.41 IU/mL versus 1.2 IU/mL (WHO) and 12.7 pg/mL versus 20.1 pg/mL (AFSSAPS); GS HIV Combo Ag/Ab EIA also demonstrated slightly better specificity compared to ARCHITECT HIV Ag/Ab Combo (100% versus 99.7%). The 4th generation HIV Combo tests detected seroconversion 7-11 days earlier than the 3rd generation HIV antibody only EIAs. Both 4th generation immunoassays demonstrated excellent performance in sensitivity, with the reduction of the serological window period (7-11 days earlier detection than the 3rd generation HIV tests). However, GS HIV Combo Ag/Ab demonstrated improved HIV antigen analytical sensitivity and slightly better specificity when compared to ARCHITECT HIV Ag/Ab Combo assay, with higher positive predictive values (PPV) for low prevalence populations. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. Clostridium difficile infection diagnostics - evaluation of the C. DIFF Quik Chek Complete assay, a rapid enzyme immunoassay for detection of toxigenic C. difficile in clinical stool samples.

    PubMed

    Johansson, Karin; Karlsson, Hanna; Norén, Torbjörn

    2016-11-01

    Diagnostic testing for Clostridium difficile infection (CDI) has, in recent years, seen the introduction of rapid dual-EIA (enzyme immunoassay) tests combining species-specific glutamate dehydrogenase (GDH) with toxin A/B. In a prospective study, we compared the C. DIFF Quik Chek Complete test to a combination of selective culture (SC) and loop-mediated isothermal amplification (LAMP) of the toxin A gene. Of 419 specimens, 68 were positive in SC including 62 positive in LAMP (14.7%). The combined EIA yielded 82 GDH positives of which 47 were confirmed toxin A/B positive (11%) corresponding to a sensitivity and specificity of 94% for GDH EIA compared to SC and for toxin A/B EIA a sensitivity of 71% and a specificity of 99% compared to LAMP. Twenty different PCR ribotypes were evenly distributed except for UK 081 where only 25% were toxin A/B positive compared to LAMP. We propose a primary use of a combined GDH toxin A/B EIA permitting a sensitive 1-h result of 379 of 419 (90%, all negatives plus GDH and toxin EIA positives) referred specimens. The remaining 10% being GDH positive should be tested for toxin A/B gene on the same day and positive results left to a final decision by the physician. © 2016 APMIS. Published by John Wiley & Sons Ltd.

  5. Evaluation of diagnostic serological results in cases of suspected primary syphilis infection.

    PubMed

    Gratzer, Beau; Pohl, Daniel; Hotton, Anna L

    2014-05-01

    Reverse sequence screening for syphilis, in which an automatable treponemal assay (enzyme immunoassay [EIA]/chemiluminescence assay [CIA]) is performed first and followed by a nontreponemal test for reactive specimens, has been used increasingly in the United States. The EIA is objective, efficient, and believed to be more sensitive than the rapid plasma reagin (RPR) because treponemal antibodies appear before nontreponemal antibodies. We sought to compare the sensitivity of a commonly used EIA, the Trep-Sure EIA (TS-EIA), to the RPR in cases of suspected primary syphilis infection in our clinic. A retrospective medical record review of patients with sexually transmitted infection clinic visits from January 2009 to December 2011 was conducted, and 52 patients met the following inclusion criteria: suspected primary syphilis symptoms, at least 1 positive syphilis test result at visit, and no history of syphilis. Sensitivity analyses compared the TS-EIA and RPR, using the reference standard of concordantly positive/reactive TS-EIA/RPR or positive fluorescent treponemal antibody absorption test (FTA-ABS) result. We considered equivocal TS-EIA results to be positive for sensitivity calculations because such results typically reflex to additional testing and therefore may still result in identifying new infections. Twenty-eight (53.8%) of the 52 patients had a positive or equivocal TS-EIA. Twenty-five (89.3%) of those were RPR reactive; the remaining 3 (10.7%) were RPR nonreactive, FTA-ABS positive. Forty patients (76.9%) had a positive RPR, including 15 patients (37.5%) with negative TS-EIA results; all 15 were FTA-ABS positive. Nine additional patients were TS-EIA negative and RPR nonreactive but had a positive FTA-ABS result. The RPR was significantly more sensitive than the EIA (76.9% vs. 53.8%, P = 0.005). Trep-Sure EIA positivity was also significantly associated with higher median RPR titer (P = 0.011). Use of the TS-EIA may result in underdetection of primary syphilis compared with the RPR. Further evaluation of the sensitivity of the TS-EIA in high-morbidity settings is warranted before the adoption of reverse sequence screening algorithms.

  6. Widespread occurrence of low levels of alternariol in apple and tomato products, as determined by comparative immunochemical assessment using monoclonal and polyclonal antibodies.

    PubMed

    Ackermann, Yvonne; Curtui, Valeriu; Dietrich, Richard; Gross, Madeleine; Latif, Hadri; Märtlbauer, Erwin; Usleber, Ewald

    2011-06-22

    This study investigated the production of polyclonal (pAB) antibodies and the first time production of monoclonal (mAB) antibodies against the mycotoxin alternariol, and their implementation in enzyme immunoassay (EIA) for the rapid determination of alternariol in foods. Both EIAs were highly sensitive, with detection limits (IC₂₀) of 35 ± 6.9 pg/mL (mAb EIA) and 59 ± 16 pg/mL (pAb EIA). Food products (n = 109; apple and tomato products, white wine) from German retail shops were analyzed. At a detection limit of 1-2 μg/kg, alternariol at 1-13 μg/kg was found with high frequency in apple (67%) and tomato (93%) products. Tomatoes with visible signs of Alternaria infection, stored at room temperature for up to 4 weeks, contained alternariol at levels up to 50 mg/kg, as determined by EIA and HPLC-FLD. It is concluded that the alternariol immunoassays present a versatile screening tool which could facilitate food control for Alternaria toxins.

  7. Clinical laboratory verification of thyroglobulin concentrations in the presence of autoantibodies to thyroglobulin: comparison of EIA, radioimmunoassay and LC MS/MS measurements in an Urban Hospital.

    PubMed

    Wheeler, Sarah E; Liu, Li; Blair, Harry C; Sivak, Richard; Longo, Nancy; Tischler, Jeffery; Mulvey, Kathryn; Palmer, Octavia M Peck

    2017-12-08

    Thyroglobulin (Tg) measurements assess recurrence in post-thyroidectomy thyroid cancer patients. Tg measurements by enzyme immunoassays (EIA) can be falsely elevated by interference from Tg autoantibodies (TgAb). Radioimmunoassay (RIA) is less susceptible to TgAb interference and has been the standard-of-care test for TgAb positive patients. Recently developed liquid chromatography tandem mass spectrometry (LC-MS/MS) methods may eliminate TgAb interference. We assessed the performance of Tg measurements by EIA, RIA and LC-MS/MS to evaluate TgAb interference differences. We measured TgAb and Tg in 50 plasma samples from 40 patients in whom Tg measurement was part of their routine follow-up and 10 healthy volunteers. Discrepancy between EIA and both LC-MS/MS and RIA was observed at low Tg concentrations (≤ 7.55 ng/mL) in TgAb positive specimens (LC-MS/MS = 1.9 * EIA - 0.03, r = 0.68). RIA and LC-MS/MS Tg measurements in TgAb positive specimens with low Tg concentrations had improved correlation but demonstrated bias (LC MS/MS = 0.6 * RIA - 1.4, r = 0.90). Disagreement between methods may be attributed to LC-MS/MS reported Tg concentrations as undetectable compared to RIA. It seems likely that most discrepant cases are falsely elevated in RIA due to TgAb interference, however, some cases appear below the detection limit of LC-MS/MS; implementation of LC-MS/MS by clinicians will require lower detection limits.

  8. [Detecting the markers of HIV infection with the new enzyme immunoassay diagnostic kit "DS-EIA-HIV-AB-AG-SPECTRUM" at the laboratories of AIDS prevention and control centers in the Volga Federal District].

    PubMed

    Ivanova, N I; Peksheva, O Iu

    2009-03-01

    A possibility of simultaneously detecting specific antibodies to HIV-1 and HIV-2 by enzyme immunoassay (EIA) at lower concentrations than those by immunoblotting (IB), and well as an additional possibility of earlier diagnosis of HIV infection, by identifying the HIV-1 antigen p24 lay the foundation of the "DS-EIA-HIV-AB-AG-SPECTRUM" test system made by OOO "Research-and-Production Association "Diagnosticheskiye Sistemy" (Diagnostic Systems). These peculiarities were compared with those of IB at a number of laboratories of AIDS prevention and control centers in the Volga Federal District, by using native serum/plasma samples and a specially designed control panel. The analysis of the conducted studies to identify HIV-1 and HIV-2 antibodies and HIV-1 antigen p24 in 65 plasma/serum samples in the "DS-EIA-HIV-AB-AG-SPECTRUM" and "LIA-HIV-1/2" (OOO "Niarmedik plus") test systems while confirming the positive result indicated agreement in 57 (87.7%) cases. The diagnostic possibilities of the "DS-EIA-HIV-AB-AG-SPECTRUM" test system versus the "New Lav-Blot I" one to make a laboratory diagnosis of HIV infection were studied. Irrefragable answers as to the availability of HIV-1 markers in the study serum samples on the enciphered panel were provided by IB in 73.3% of cases and EIA in 92%.

  9. Investigation of an algorithm for anti HCV EIA reactivity in blood donor screening in Turkey in the absence of nucleic acid amplification screening.

    PubMed

    Karakoc, Ayse Esra; Berkem, Rukiye; Irmak, Hasan; Demiroz, Ali Pekcan; Yenicesu, Idil; Ertugrul, Nigar; Arslan, Önder; Kemahli, Sabri; Yilmaz, Sevinc; Ozcebe, Osman; Kara, Abdurrahman; Ozet, Gulsum; Acikgoz, Ziya Cibali; Acikgoz, Tulin

    2017-10-01

    In this study we aimed to propose an algorithm for initial anti HCV EIA reactive blood donations in Turkey where nucleic acid amplification tests are not yet obligatory for donor screening. A total of 416 anti HCV screening test reactive donor samples collected from 13 blood centers from three cities in Turkey were tested in duplicate by Ortho HCV Ab Version 3.0 and Radim HCV Ab. All the repeat reactive samples were tested by INNO-LIA HCV Ab 3.0 or Chiron RIBA HCV 3.0 and Abbott Real Time HCV. Intra-assay correlations were calculated with Pearson r test. ROC analysis was used to study the relationship between EIA tests and the confirmatory tests. The number of repeat reactive results with Ortho EIA were 221 (53.1%) whereas that of microEIA, 62 (14.9%). Confirmed positivity rate was 14.6% (33/226) by RIBA and 10.6% (24/226) by NAT. Reactive PCR results were predicted with 100% sensitivity and 95% specificity with S/CO levels of 8.1 with Ortho EIA and 3.4 with microEIA. Repeat reactivity rates declined with a second HCV antibody assay. Samples repeat reactive with one HCV antibody test and negative with the other were all NAT negative. All the NAT reactive samples were RIBA positive. None of the RIBA indeterminate or negative samples were NAT reactive. Considering the threshold values for EIA kits determined by ROC analysis NAT was decided to be performed for the samples above the threshold value and a validated supplemental HCV antibody test for the samples below. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. A rapid magnetic particle-based enzyme immunoassay for human cytomegalovirus glycoprotein B quantification.

    PubMed

    Pires, F; Arcos-Martinez, M Julia; Dias-Cabral, A Cristina; Vidal, Juan C; Castillo, Juan R

    2018-04-17

    Human cytomegalovirus (HCMV) is a herpes virus that can cause severe infections. Still, the available methods for its diagnostic have the main disadvantage of requiring long time to be performed. In this work, a simple magnetic particle-based enzyme immunoassay (mpEIA) for the quantification of glycoprotein B of Human cytomegalovirus (gB-HCMV) in urine samples is proposed. The immunosensor scheme is based on the analyte protein gB-HCMV sandwiched between a primary monoclonal antibody, (MBs-PrG-mAb1), and a secondary anti-gB-HCMV antibody labelled with Horseradish peroxidase (Ab2-HRP) to allow spectrophotometric detection. The mpEIA analytical performance was tested in urine samples, showing a linear dependence between gB-HCMV concentration and the absorbance signal at 450 nm in a range of concentrations from 90 to 700 pg mL -1 . The calculated detection limits for gB-HCMV were 90 ± 2 pg mL -1 and the RSD was about 6.7% in urine samples. The immunosensor showed good selectivity against other viruses from Herpesviridae family, namely varicella zoster and Epstein Barr viruses. The recoveries of spiked human urine samples at 0.30-0.50 ng mL -1 concentration levels of gB-HCMV ranged between 91 to 105%. The proposed mpEIA method was validated following the guidelines of the European Medicines Agency (EMEA-2014), and allows rapid, successful and easy quantification of gB-HCMV in urine samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Diagnosis of Clostridium difficile-associated disease: examination of multiple algorithms using toxin EIA, glutamate dehydrogenase EIA and loop-mediated isothermal amplification.

    PubMed

    Bamber, A I; Fitzsimmons, K; Cunniffe, J G; Beasor, C C; Mackintosh, C A; Hobbs, G

    2012-01-01

    The laboratory diagnosis of Clostridium difficile infection (CDI) needs to be accurate and timely to ensure optimal patient management, infection control and reliable surveillance. Three methods are evaluated using 810 consecutive stool samples against toxigenic culture: CDT TOX A/B Premier enzyme immunoassay (EIA) kit (Meridian Bioscience, Europe), Premier EIA for C. difficile glutamate dehydrogenase (GDH) (Meridian Bioscience, Europe) and the Illumigene kit (Meridian Bioscience, Europe), both individually and within combined testing algorithms. The study revealed that the CDT TOX A/B Premier EIA gave rise to false-positive and false-negative results and demonstrated poor sensitivity (56.47%), compared to Premier EIA for C. difficile GDH (97.65%), suggesting this GDH EIA can be a useful negative screening method. Results for the Illumigene assay alone showed sensitivity, specificity, negative predictive value (NPV) and positive predictive value (PPV) of 91.57%, 98.07%, 99.03% and 84.44%, respectively. A two-stage algorithm using Premier EIA for C. difficile GDH/Illumigene assay yielded superior results compared with other testing algorithms (91.57%, 98.07%, 99.03% and 84.44%, respectively), mirroring the Illumigene performance. However, Illumigene is approximately half the cost of current polymerase chain reaction (PCR) methods, has a rapid turnaround time and requires no specialised skill base, making it an attractive alternative to assays such as the Xpert C. difficile assay (Cepheid, Sunnyvale, CA). A three-stage algorithm offered no improvement and would hamper workflow.

  12. Performance evaluation of the Bio-Rad Laboratories GS HIV Combo Ag/Ab EIA, a 4th generation HIV assay for the simultaneous detection of HIV p24 antigen and antibodies to HIV-1 (groups M and O) and HIV-2 in human serum or plasma.

    PubMed

    Bentsen, Christopher; McLaughlin, Lisa; Mitchell, Elizabeth; Ferrera, Carol; Liska, Sally; Myers, Robert; Peel, Sheila; Swenson, Paul; Gadelle, Stephane; Shriver, M Kathleen

    2011-12-01

    A multi-center study was conducted to evaluate the Bio-Rad GS HIV Combo Ag/Ab EIA, a 4th generation HIV-1/HIV-2 assay for the simultaneous detection of HIV p24 antigen and antibodies to HIV-1 (groups M and O) and HIV-2 in human serum or plasma in adult and pediatric populations. The objectives of the study were to assess assay performance for the detection of acute HIV infections; sensitivity in known HIV positive samples; percent agreement with HIV status; specificity in low and high risk individuals of unknown HIV status; and to compare assay performance to a 3rd generation HIV assay. The evaluation included testing 9150 samples at four U.S. clinical trial sites, using three kit lots. Unlinked samples were from routine testing, repositories or purchased from vendors. GS HIV Combo Ag/Ab EIA detection in samples from individuals in two separate populations with acute HIV infection was 95.2% (20/21) and 86.4% (38/44). Sensitivity was 100% (1603/1603) in known antibody positive [HIV-1 Groups M and O, and HIV-2] samples. HIV p24 antigen detection was 100% (53/53) in HIV-1 culture supernatants. HIV-1 seroconversion panel detection improved by a range of 0-20 days compared to a 3rd generation HIV test. Specificity was 99.9% (5989/5996) in low risk, 99.9% (959/960) in high risk and 100% (100/100) in pediatric populations. The GS HIV Combo Ag/Ab EIA significantly reduced the diagnostic window when compared to the 3rd generation screening assay, enabling earlier diagnosis of HIV infection. The performance parameters of the Bio-Rad GS HIV Combo Ag/Ab EIA are well suited for use in HIV diagnostic settings. Copyright © 2011 Elsevier B.V. All rights reserved.

  13. Clinical comparison of the Treponema pallidum CAPTIA syphilis-G enzyme immunoassay with the fluorescent treponemal antibody absorption immunoglobulin G assay for syphilis testing.

    PubMed

    Halling, V W; Jones, M F; Bestrom, J E; Wold, A D; Rosenblatt, J E; Smith, T F; Cockerill, F R

    1999-10-01

    Recently, a treponema-specific immunoglobulin G (IgG) enzyme immunoassay (EIA), the CAPTIA Syphilis-G (Trinity Biotech, Jamestown, N.Y.), has become available as a diagnostic test for syphilis. A total of 89 stored sera previously tested by the fluorescent treponemal antibody absorption (FTA-ABS) IgG assay were evaluated by the CAPTIA EIA. The FTA-ABS IgG procedure was performed by technologists unblinded to results of rapid plasmid reagin (RPR) testing of the same specimens. Borderline CAPTIA-positive samples (antibody indices of >/=0.650 and 0.900, the sample was considered positive. Thirteen of 89 (15%) samples had discrepant results. Compared to the FTA-ABS assay, the CAPTIA EIA had a sensitivity and specificity and positive and negative predictive values of 70.7, 97.9, 96.7, and 79.7%, respectively. In another analysis, discrepancies between results were resolved by repeated FTA-ABS testing (technologists were blinded to previous RPR results) and patient chart reviews. Seven CAPTIA-negative samples which were previously interpreted (unblinded) as minimally reactive by the FTA method were subsequently interpreted (blinded) as nonreactive. One other discrepant sample (CAPTIA negative and FTA-ABS positive [at an intensity of 3+], unblinded) was FTA negative with repeated testing (blinded). For the five remaining discrepant samples, chart reviews indicated that one patient (CAPTIA negative and FTA-ABS positive [minimally reactive], blinded) had possible syphilis. These five samples were also evaluated and found to be negative by another treponema-specific test, the Treponema pallidum microhemagglutination assay. Therefore, after repeated testing and chart reviews, 2 of the 89 (2%) samples had discrepant results; the adjusted sensitivity, specificity, and positive and negative predictive values were 96.7, 98.3, 96.7, and 98.3%, respectively. This study demonstrates that the CAPTIA IgG EIA is a reliable method for syphilis testing and that personnel performing tests which require subjective interpretation, like the FTA-ABS test, may be biased by RPR test results.

  14. Clinical Comparison of the Treponema pallidum CAPTIA Syphilis-G Enzyme Immunoassay with the Fluorescent Treponemal Antibody Absorption Immunoglobulin G Assay for Syphilis Testing

    PubMed Central

    Halling, V. W.; Jones, M. F.; Bestrom, J. E.; Wold, A. D.; Rosenblatt, J. E.; Smith, T. F.; Cockerill, F. R.

    1999-01-01

    Recently, a treponema-specific immunoglobulin G (IgG) enzyme immunoassay (EIA), the CAPTIA Syphilis-G (Trinity Biotech, Jamestown, N.Y.), has become available as a diagnostic test for syphilis. A total of 89 stored sera previously tested by the fluorescent treponemal antibody absorption (FTA-ABS) IgG assay were evaluated by the CAPTIA EIA. The FTA-ABS IgG procedure was performed by technologists unblinded to results of rapid plasmid reagin (RPR) testing of the same specimens. Borderline CAPTIA-positive samples (antibody indices of ≥0.650 and ≤0.900) were retested; if the second analysis produced an index of >0.900, the sample was considered positive. Thirteen of 89 (15%) samples had discrepant results. Compared to the FTA-ABS assay, the CAPTIA EIA had a sensitivity and specificity and positive and negative predictive values of 70.7, 97.9, 96.7, and 79.7%, respectively. In another analysis, discrepancies between results were resolved by repeated FTA-ABS testing (technologists were blinded to previous RPR results) and patient chart reviews. Seven CAPTIA-negative samples which were previously interpreted (unblinded) as minimally reactive by the FTA method were subsequently interpreted (blinded) as nonreactive. One other discrepant sample (CAPTIA negative and FTA-ABS positive [at an intensity of 3+], unblinded) was FTA negative with repeated testing (blinded). For the five remaining discrepant samples, chart reviews indicated that one patient (CAPTIA negative and FTA-ABS positive [minimally reactive], blinded) had possible syphilis. These five samples were also evaluated and found to be negative by another treponema-specific test, the Treponema pallidum microhemagglutination assay. Therefore, after repeated testing and chart reviews, 2 of the 89 (2%) samples had discrepant results; the adjusted sensitivity, specificity, and positive and negative predictive values were 96.7, 98.3, 96.7, and 98.3%, respectively. This study demonstrates that the CAPTIA IgG EIA is a reliable method for syphilis testing and that personnel performing tests which require subjective interpretation, like the FTA-ABS test, may be biased by RPR test results. PMID:10488183

  15. Demographic, risk factors and motivations among blood donors with reactive serologic tests for syphilis in São Paulo, Brazil.

    PubMed

    Ferreira, S C; de Almeida-Neto, C; Nishiya, A S; Oliveira, C D L; Ferreira, J E; Alencar, C S; Levi, J E; Salles, N A; Mendrone, A; Sabino, E C

    2014-06-01

    To identify the demographic characteristics, risk factors and motivations for donating among blood donors with reactive serologic tests for syphilis. Post-donation interviews with syphilis seropositive blood donors improve recruitment and screening strategies. This case-control study compares 75 Venereal Disease Research Laboratory (VDRL) > 8, EIA+ (enzyme immunoassay) and FTA-ABS+ (fluorescent treponemal antibody); 80 VDRL-, EIA+ and FTA-ABS+; and 34 VDRL- and EIA- donors between 2004 and 2009. Donors were assessed by their demographic characteristics, sexual behaviour, history of alcohol and illicit drugs use, and motivations to donate. Donors with VDRL > 8 were more likely to be divorced [AOR = 12·53; 95% confidence interval (CI) 1·30-120·81], to have had more than six sexual partners (AOR=7·1; 95% CI 1·12-44·62) and to report male-male-sex in the past 12 months (AOR=8·18; 95% CI 1·78-37·60). Donors with VDRL-, EIA+ and FTA-ABS+ were less likely to be female (AOR=0·26; 95% CI 0·07-0·96), more likely to be older (AOR=10·2; 95% CI 2·45-42·58 ≥ 39 and <60 years old) and to have had more than six sexual partners in the past 12 months (AOR = 8·37; 95% CI 1·49-46·91). There was no significant difference among groups regarding illicit drugs use; 30·7% (VDRL > 8) and 12·5% (VDRL-, EIA+ and FTA-ABS+) of donors reported that they had been at risk for HIV infection (P = 0·004). One-third of donors came to the blood bank to help a friend or a relative who needed blood. Although donors exposed to syphilis reported and recognised some high risk behaviour, most were motivated by direct appeal to donate blood. Monitoring the risk profile of blood donors can benefit public health and improve blood safety. © 2014 The Authors. Transfusion Medicine © 2014 British Blood Transfusion Society.

  16. Comparative evaluation of the INNO-LIA syphilis score and the MarDx Treponema pallidum immunoglobulin G Marblot test assays for the serological diagnosis of syphilis.

    PubMed

    Lam, T K; Lau, H Y; Lee, Y P; Fung, S M; Leung, W L; Kam, K M

    2010-02-01

    We evaluated the performance of two immunoblot assays: the INNO-LIA Syphilis Score (LIA) and the MarDx T. pallidum IgG Marblot Test (TWB), as compared with that of the Murex ICE Syphilis enzyme immunoassay (EIA), the Serodia Treponema pallidum particle agglutination (TPPA) assay and the fluorescent treponemal antibody-absorption (FTA-abs) assay, for the serological diagnosis of syphilis using serum samples of 135 attendees of the social hygiene clinics of the Department of Health in Hong Kong newly diagnosed with syphilis and provided with clinical stages (39 in primary, 20 in secondary, 18 in early latent and 58 in latent of unknown duration) and of 43 normal healthy subjects between October and December 2004. The differences in the overall sensitivities of the LIA assay and the EIA/TPPA/FTA-abs assays were not statistically significant (P > 0.05) whereas the overall sensitivity of the TWB assay was significantly lower (P < 0.05) than the overall sensitivities of the EIA, the TPPA and the FTA-abs assays. The LIA assay had an overall sensitivity of 94.1% (95% CI 88.7-97.0%) whereas the TWB assay 65.2% (95% CI 56.8-72.7%). Both the LIA and the TWB assays have a specificity of 100%. When consensus results were derived from the most predominant results of the EIA, the TPPA and the FTA-abs assays, the LIA assay had a positive agreement with the consensus results of 98.5% (95% CI 94.5-99.6%) whereas the TWB assay 68.2% (95% CI 59.8-75.6%). Therefore, the LIA assay performed significantly better (P < 0.05) than the TWB assay. The LIA assay can be considered to be a valid alternative confirmatory test for the serological diagnosis of syphilis.

  17. New fluorimetric assay of horseradish peroxidase using sesamol as substrate and its application to EIA.

    PubMed

    Arakawa, Hidetoshi; Nakabayashi, Shigeo; Ohno, Ken-Ichi; Maeda, Masako

    2012-04-01

    Horseradish peroxidase (HRP) is generally used as a label enzyme in enzyme immunoassay (EIA). The procedure used for HRP detection in EIA is critical for sensitivity and precision. This paper describes a novel fluorimetric assay for horseradish peroxidase (HRP) using sesamol as substrate. The principle of the assay is as follow: sesamol (3,4-methylenedioxy phenol) is reacted enzymatically in the presence of hydrogen peroxide to produce dimeric sesamol. The dimer is fluorescent and can be detected sensitively at ex. 347 nm, em. 427 nm. The measurable range of HRP was 1.0×10 -18 to 1.0×10 -15  mol/assay, with a detection limit of 1.0×10 -18  mol/assay. The coefficient of variation (CV, n =8) was examined at each point on the standard curve, with a mean CV percentage of 3.8%. This assay system was applied to thyroid stimulating hormone (TSH) EIA using HRP as the label enzyme.

  18. Low sensitivity of fecal toxin A/B enzyme immunoassay for diagnosis of Clostridium difficile infection in immunocompromised patients.

    PubMed

    Erb, S; Frei, R; Strandén, A M; Dangel, M; Tschudin-Sutter, S; Widmer, A F

    2015-11-01

    The optimal approach in laboratory diagnosis of Clostridium difficile infection (CDI) is still not well defined. Toxigenic culture (TC) or alternatively fecal toxin assay by cell cytotoxicity neutralization assay are considered to be the reference standard, but these methods are time-consuming and labor intensive. In many medical centers, diagnosis of CDI is therefore still based on fecal toxin A/B enzyme immunoassay (EIA) directly from stool alone, balancing cost and speed against limited diagnostic sensitivity. The aim of the study was to assess in which patient population the additional workload of TC is justified. All consecutive stool specimens submitted for diagnosis of suspected CDI between 2004 and 2011 at a tertiary-care center were examined by toxin EIA and TC. Clinical data of patients with established diagnosis of CDI were collected in a standardized case-report form. From 12,481 stool specimens submitted to the microbiologic laboratory, 480 (3.8%) fulfilled CDI criteria; 274 (57.1%) were diagnosed by toxin EIA; and an additional 206 (42.9%) were diagnosed by TC when toxin EIA was negative. Independent predictors for negative toxin EIA but positive TC were high-dose corticosteroids (odds ratio (OR) 2.97, 95% confidence interval (CI) 1.50-5.90, p 0.002), leukocytopenia <1000/μL (OR 2.52, 95% CI 1.22-5.23, p 0.013) and nonsevere CDI (OR 2.21, 95% CI 1.39-3.50, p 0.001). There was no difference in outcomes such as in-hospital mortality and recurrence between both groups. In conclusion, negative toxin EIA does not rule out CDI in immunocompromised patients in the setting of relevant clinical symptoms. Methods with improved sensitivity such as TC or PCR should be used, particularly in this patient population. Copyright © 2015 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  19. Estimates of Annual Fossil-Fuel CO2 Emitted for Each State in the U.S.A. and the District of Columbia for Each Year from 1960 through 2001

    DOE Data Explorer

    Blasing, T. J. [Carbon Dioxide Information Analysis Center (CDIAC), Oak Ridge National Laboratory (ORNL), Oak Ridge, Tennessee (USA); Marland, Gregg [Carbon Dioxide Information Analysis Center (CDIAC), Oak Ridge National Laboratory (ORNL), Oak Ridge, Tennessee (USA); Broniak, Christine [Oregon State Univ., Corvallis, OR (United States)

    2004-01-01

    Consumption data for coal, petroleum, and natural gas are multiplied by their respective thermal conversion factors, which are in units of heat energy per unit of fuel consumed (i.e., per cubic foot, barrel, or ton), to calculate the amount of heat energy derived from fuel combustion. The thermal conversion factors are given in Appendix A of each issue of Monthly Energy Review, published by the Energy Information Administration (EIA) of the U.S. Department of Energy (DOE). Results are expressed in terms of heat energy obtained from each fuel type. These energy values were obtained from the State Energy Data Report (EIA, 2003a), ( http://www.eia.doe.gov/emeu/states/sep_use/total/csv/use_csv.html), and served as our basic input. The energy data are also available in hard copy from the Energy Information Administration, U.S. Department of Energy, as the State Energy Data Report (EIA, 2003a,b).

  20. Cost-effectiveness of a modified two-step algorithm using a combined glutamate dehydrogenase/toxin enzyme immunoassay and real-time PCR for the diagnosis of Clostridium difficile infection.

    PubMed

    Vasoo, Shawn; Stevens, Jane; Portillo, Lena; Barza, Ruby; Schejbal, Debra; Wu, May May; Chancey, Christina; Singh, Kamaljit

    2014-02-01

    The analytical performance and cost-effectiveness of the Wampole Toxin A/B EIA, the C. Diff. Quik Chek Complete (CdQCC) (a combined glutamate dehydrogenase antigen/toxin enzyme immunoassay), two RT-PCR assays (Progastro Cd and BD GeneOhm) and a modified two-step algorithm using the CdQCC reflexed to RT-PCR for indeterminate results were compared. The sensitivity of the Wampole Toxin A/B EIA, CdQCC (GDH antigen), BD GeneOhm and Progastro Cd RT-PCR were 85.4%, 95.8%, 100% and 93.8%, respectively. The algorithm provided rapid results for 86% of specimens and the remaining indeterminate results were resolved by RT-PCR, offering the best balance of sensitivity and cost savings per test (algorithm ∼US$13.50/test versus upfront RT-PCR ∼US$26.00/test). Copyright © 2012. Published by Elsevier B.V.

  1. Two-step glutamate dehydrogenase antigen real-time polymerase chain reaction assay for detection of toxigenic Clostridium difficile.

    PubMed

    Goldenberg, S D; Cliff, P R; Smith, S; Milner, M; French, G L

    2010-01-01

    Current diagnosis of Clostridium difficile infection (CDI) relies upon detection of toxins A/B in stool by enzyme immunoassay [EIA(A/B)]. This strategy is unsatisfactory because it has a low sensitivity resulting in significant false negatives. We investigated the performance of a two-step algorithm for diagnosis of CDI using detection of glutamate dehydrogenase (GDH). GDH-positive samples were tested for C. difficile toxin B gene (tcdB) by polymerase chain reaction (PCR). The performance of the two-step protocol was compared with toxin detection by the Meridian Premier EIA kit in 500 consecutive stool samples from patients with suspected CDI. The reference standard among samples that were positive by either EIA(A/B) or GDH testing was culture cytotoxin neutralisation (culture/CTN). Thirty-six (7%) of 500 samples were identified as true positives by culture/CTN. EIA(A/B) identified 14 of the positive specimens with 22 false negatives and two false positives. The two-step protocol identified 34 of the positive samples with two false positives and two false negatives. EIA(A/B) had a sensitivity of 39%, specificity of 99%, positive predictive value of 88% and negative predictive value of 95%. The two-step algorithm performed better, with corresponding values of 94%, 99%, 94% and 99% respectively. Screening for GDH before confirmation of positives by PCR is cheaper than screening all specimens by PCR and is an effective method for routine use. Current EIA(A/B) tests for CDI are of inadequate sensitivity and should be replaced; however, this may result in apparent changes in CDI rates that would need to be explained in national surveillance statistics. Copyright 2009 The Hospital Infection Society. Published by Elsevier Ltd. All rights reserved.

  2. Pooled nucleic acid testing increases the diagnostic yield of acute HIV infections in a high-risk population compared to 3rd and 4th generation HIV enzyme immunoassays.

    PubMed

    Krajden, Mel; Cook, Darrel; Mak, Annie; Chu, Ken; Chahil, Navdeep; Steinberg, Malcolm; Rekart, Michael; Gilbert, Mark

    2014-09-01

    We compared a 3rd generation (gen) and two 4th gen HIV enzyme immunoassays (EIA) to pooled nucleic acid testing (PNAT) for the identification of pre- and early seroconversion acute HIV infection (AHI). 9550 specimens from males >18 year from clinics attended by men who have sex with men were tested by Siemens ADVIA Centaur(®) HIV 1/O/2 (3rd gen) and HIV Combo (4th gen), as well as by Abbott ARCHITECT(®) HIV Ag/Ab Combo (4th gen). Third gen non-reactive specimens were also tested by Roche COBAS(®) Ampliprep/COBAS® TaqMan HIV-1 Test v.2 in pools of 24 samples. Sensitivity and specificity of the three EIAs for AHI detection were compared. 7348 persons contributed 9435 specimens and had no evidence of HIV infection, 79 (94 specimens) had established HIV infection, 6 (9 specimens) had pre-seroconversion AHI and 9 (12 specimens) had early seroconversion AHI. Pre-seroconversion AHI cases were not detected by 3rd gen EIA, whereas 2/6 (33.3%) were detected by Siemens 4th gen, 4/6 (66.7%) by Abbott 4th gen and 6/6 (100%) by PNAT. All three EIAs and PNAT detected all individuals with early seroconversion AHI. Overall sensitivity/specificity for the EIAs relative to WB or NAT resolved infection status was 93.6%/99.9% for Siemens 3rd gen, 95.7%/99.7% for Siemens 4th gen and 97.9%/99.2% for Abbott 4th gen. While both 4th gen EIAs demonstrated improved sensitivity for AHI compared to 3rd gen EIA, PNAT identified more AHI cases than either 4th gen assay. PNAT is likely to remain a useful strategy to identify AHI in high-risk populations. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Diagnostic accuracy of tests to detect Hepatitis C antibody: a meta-analysis and review of the literature.

    PubMed

    Tang, Weiming; Chen, Wen; Amini, Ali; Boeras, Debi; Falconer, Jane; Kelly, Helen; Peeling, Rosanna; Varsaneux, Olivia; Tucker, Joseph D; Easterbrook, Philippa

    2017-11-01

    Although direct-acting antivirals can achieve sustained virological response rates greater than 90% in Hepatitis C Virus (HCV) infected persons, at present the majority of HCV-infected individuals remain undiagnosed and therefore untreated. While there are a wide range of HCV serological tests available, there is a lack of formal assessment of their diagnostic performance. We undertook a systematic review and meta-analysis to evaluate he diagnostic accuracy of available rapid diagnostic tests (RDT) and laboratory based EIA assays in detecting antibodies to HCV. We used the PRISMA checklist and Cochrane guidance to develop our search protocol. The search strategy was registered in PROSPERO (CRD42015023567). The search focused on hepatitis C, diagnostic tests, and diagnostic accuracy within eight databases (MEDLINE, EMBASE, the Cochrane Central Register of Controlled Trials, Science Citation Index Expanded, Conference Proceedings Citation Index-Science, SCOPUS, Literatura Latino-Americana e do Caribe em Ciências da Saúde and WHO Global Index Medicus. Studies were included if they evaluated an assay to determine the sensitivity and specificity of HCV antibody (HCV Ab) in humans. Two reviewers independently extracted data and performed a quality assessment of the studies using the QUADAS tool. We pooled test estimates using the DerSimonian-Laird method, by using the software R and RevMan. 5.3. A total of 52 studies were identified that included 52,673 unique test measurements. Based on five studies, the pooled sensitivity and specificity of HCV Ab rapid diagnostic tests (RDTs) were 98% (95% CI 98-100%) and 100% (95% CI 100-100%) compared to an enzyme immunoassay (EIA) reference standard. High HCV Ab RDTs sensitivity and specificity were observed across screening populations (general population, high risk populations, and hospital patients) using different reference standards (EIA, nucleic acid testing, immunoblot). There were insufficient studies to undertake subanalyses based on HIV co-infection. Oral HCV Ab RDTs also had excellent sensitivity and specificity compared to blood reference tests, respectively at 94% (95% CI 93-96%) and 100% (95% CI 100-100%). Among studies that assessed individual oral RDTs, the eight studies revealed that OraQuick ADVANCE® had a slightly higher sensitivity (98%, 95% CI 97-98%) compared to the other oral brands (pooled sensitivity: 88%, 95% CI 84-92%). RDTs, including oral tests, have excellent sensitivity and specificity compared to laboratory-based methods for HCV antibody detection across a wide range of settings. Oral HCV Ab RDTs had good sensitivity and specificity compared to blood reference standards.

  4. Development and validation of a sensitive enzyme immunoassay (EIA) for blood plasma cortisol in female cattle, buffaloes, and goats.

    PubMed

    Yadav, R; Mohan, K; Kumar, V; Sarkar, M; Nitu, K; Meyer, H H D; Prakash, B S

    2013-08-01

    A highly sensitive enzyme immunoassay (EIA) that used the second antibody coating technique and the cortisol-horseradish peroxidase conjugate as a label for determination of free and total cortisol in blood plasma of dairy animals (cows, buffaloes, and goats) was developed. For biological validation of the EIA, blood samples were collected from the animals at 48 and 24 h before and 0, 12, 24, 36, 48, 60, 72, 84, 96, 108, 120, and 132 h after dexamethasone administration. The EIA was performed directly with 20 μL of fresh plasma (for free cortisol) and also with 20 μL of heat-treated plasma (for total cortisol) after 1:5 dilutions with PBS. Cortisol standards ranging from 0.39 to 200 pg/well/20 μL were used, and the sensitivity of the EIA procedure was found to be 0.39 pg/well/20 μL, which corresponded to 0.02 ng/mL. In comparison with RIA the EIA was at least 4 times more sensitive and required 5 times less cortisol antiserum. In female cattle, buffaloes, and goats, the total, free, and bound plasma cortisol before dexamethasone administration was significantly (P < 0.05) higher than the total, free, and bound cortisol after dexamethasone administration. It can be concluded from these studies that the direct, sensitive EIA validated for estimating the free and total cortisol concentrations was sufficiently reliable and quick for studying the dynamics of cortisol distribution in blood plasma of dairy animals. Copyright © 2013 Elsevier Inc. All rights reserved.

  5. A two-stage algorithm for Clostridium difficile including PCR: can we replace the toxin EIA?

    PubMed

    Orendi, J M; Monnery, D J; Manzoor, S; Hawkey, P M

    2012-01-01

    A two step, three-test algorithm for Clostridium difficile infection (CDI) was reviewed. Stool samples were tested by enzyme immunoassays for C. difficile common antigen glutamate dehydrogenase (G) and toxin A/B (T). Samples with discordant results were tested by polymerase chain reaction detecting the toxin B gene (P). The algorithm quickly identified patients with detectable toxin A/B, whereas a large group of patients excreting toxigenic C. difficile but with toxin A/B production below detection level (G(+)T(-)P(+)) was identified separately. The average white blood cell count in patients with a G(+)T(+) result was higher than in those with a G(+)T(-)P(+) result. Copyright © 2011 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  6. Tumor radioimmunoimaging of chimeric antibody in nude mice with hepatoma xenograft

    PubMed Central

    Gong, Yi; Liu, Kang-Da; Zhou, Ge; Xue, Qiong; Chen, Shao-Liang; Tang, Zhao-You

    1998-01-01

    AIM: To study the radioimmunoimaging (RAII) using the human/mouse chimeric Ab to evaluate its targeting activity in animal models. METHODS: To chimeric Ab was labeled with 131I. RAII was performed at different intervals after injection of radio-labeled Abs in nude mice with human hepatoma xenograft, and tissue distribution of radioactivity was measured. Comparison was made in the chimeric Ab between the single segment Ab and previous murine mAb against HBxAg. RESULTS: The experimental objects developed tumor-positive image after 2 days of radio-labeled Abs injection, and the peak accumulation of radioactivity fell on the 7th day. The tumor/liver ratioactivity of the chimeric Ab, single segment Ab, anti-HBx mAb, and the control group was 281 ± 0.21, 2.44 ± 0.16, 4.60 ± 0.19, and 0.96 ± 0.14, respectively. CONCLUSION: The genetic engineering Abs have a considerable targeting activity which can be used as a novel humanized vector in the targeting treatment of liver cancer. PMID:11819217

  7. N-Sulfonyl-β-lactam hapten as an effective labeling reagent for aldolase mAb.

    PubMed

    Inokuma, Tsubasa; Fuller, Roberta P; Barbas, Carlos F

    2015-04-15

    Utilization of chemically programmed antibodies (cpAbs) is regarded to be one of the most efficient methods for the development of therapeutic systems. cpAbs can extend the half-life of programming reagents, activate immune systems via the Fc region of antibodies and achieve universal vaccination by attaching varieties of small, programmed molecules. In the current study, we aimed to develop a novel labeling reagent for the preparation of cpAbs and found that N-sulfonyl-β-lactams (NSBLs) were optimal. NSBL can be synthesized from readily available 4-(bromomethyl)benzenesulfonyl chloride via few simple manipulations and can label the aldolase monoclonal antibody (mAb) 84G3, which could not be labeled effectively by the conventional labeling reagent, N-acyl-β-lactam (NABL). We also demonstrated that the conjugate, which consists of mAb 84G3 and an NSBL bearing a biotin moiety, maintained strong binding activity to streptavidin. In addition, the stability assay of NSBL revealed that NSBLs can tolerate aqueous media without significant decomposition over 24h. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Use of the Abbott Architect HIV antigen/antibody assay in a low incidence population.

    PubMed

    Dubravac, Terry; Gahan, Thomas F; Pentella, Michael A

    2013-12-01

    With the availability of 4th generation HIV diagnostic tests which are capable of detecting acute infection, Iowa evaluated the 3rd and 4th generation HIV test and compared the performance of these products in a low incidence population. This study was conducted to evaluate the performance of an HIV antigen/antibody combination (4th generation) assay compared to an EIA 3rd generation assay. Over a 4 month period, 2037 specimens submitted for HIV screening were tested by Bio-Rad GS HIV-1/HIV-2 Plus O EIA and the Abbott Architect i1000SR HIV Ag/Ab Combo. The performance characteristics of sensitivity, specificity, positive predictive value and negative predictive value were determined. Of the 2037 specimens tested, there were 13 (0.64%) true positives detected. None of the positive specimens were from patients in the acute phase of infection. The Abbott antigen/antibody combo assay had a sensitivity, specificity, positive-predictive value and negative predictive value of 100%, 99.85%, 81.25%, and 100% respectively. The Bio-Rad EIA assay had a sensitivity, specificity, positive-predictive value and negative predictive value of 100%, 99.80%, 76.47% and 100%, respectively. The EIA had four false positive results which tested negative by the antigen/antibody assay and western blot. In a low-incidence state where early infections are less commonly encountered, the EIA assay and the antigen/antibody assay performed with near equivalency. The antigen/antibody assay had one less false positive result. While no patients were detected in the acute stage of infection, the use of the antigen/antibody assay presents the opportunity to detect an infected patient sooner and prevent transmission to others. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Labeling of monoclonal antibodies with a 67Ga-phenolic aminocarboxylic acid chelate. Part I. Chemistry and labeling technique.

    PubMed

    Schuhmacher, J; Matys, R; Hauser, H; Maier-Borst, W; Matzku, S

    1986-01-01

    As a chelating agent for labeling antibodies (Abs) with metallic radionuclides, a propionic acid substituted ethylenediamine N,N'-di-[(o-hydroxyphenyl) acetic acid] (P-EDDHA), which tightly complexes 67Ga, was synthesized. The 67Ga-P-EDDHA chelate was coupled in aqueous solution to IgG at a molar ratio of 1:1 via carbodiimide. The average coupling yield was 15%. A specific activity of 4 mCi/mg IgG could be obtained with commercially supplied 67Ga. In vitro stability was evaluated in human serum at 37 degrees C and showed a half-life of about 120 h for the release of 67Ga from the labeled Ab during the initial phase of incubation. This in vitro halflife is similar to that measured for 111In-DTPA labeled Abs. Because of the high stability of the 67Ga-P-EDDHA chelate, the in vivo formation of radioactive labeled transferrin by transchelation, as described for 111In-DTPA labeled Abs, should, however, be reduced by this labeling technique.

  10. Use of a nested PCR-enzyme immunoassay with an internal control to detect Chlamydophila psittaci in turkeys

    PubMed Central

    Van Loock, Marnix; Verminnen, Kristel; Messmer, Trudy O; Volckaert, Guido; Goddeeris, Bruno M; Vanrompay, Daisy

    2005-01-01

    Background Laboratory diagnosis of Chlamydophila psittaci, an important turkey respiratory pathogen, is difficult. To facilitate the diagnosis, a nested PCR-enzyme immunoassay (PCR-EIA) was developed to detect the Cp. psittaci outer membrane protein A (ompA) gene in pharyngeal swabs. Methods The fluorescein-biotin labelled PCR products were immobilized on streptavidin-coated microtiter plates and detected with anti-fluorescein peroxidase conjugate and a colorimetric substrate. An internal inhibition control was included to rule out the presence of inhibitors of DNA amplification. The diagnostic value of the ompA nested PCR-EIA in comparison to cell culture and a 16S-rRNA based nested PCR was assessed in pharyngeal turkey swabs from 10 different farms experiencing respiratory disease. Results The sensitivity of the nested PCR-EIA was established at 0.1 infection forming units (IFU). Specificity was 100%. The ompA nested PCR-EIA was more sensitive than the 16S-rRNA based nested PCR and isolation, revealing 105 out of 200 (52.5%) positives against 13 and 74 for the latter two tests, respectively. Twenty-nine (23.8%) out of 122 ompA PCR-EIA negatives showed the presence of inhibitors of DNA amplification, although 27 of them became positive after diluting (1/10) the specimens in PCR buffer or after phenol-chloroform extraction and subsequent ethanol precipitation. Conclusion The present study stresses the need for an internal control to confirm PCR true-negatives and demonstrates the high prevalence of chlamydiosis in Belgian turkeys and its potential zoonotic risk. The ompA nested PCR-EIA described here is a rapid, highly sensitive and specific diagnostic assay and will help to facilitate the diagnosis of Cp. psittaci infections in both poultry and man. PMID:16185353

  11. A Novel PET Imaging Using 64Cu-Labeled Monoclonal Antibody against Mesothelin Commonly Expressed on Cancer Cells

    PubMed Central

    Kobayashi, Kazuko; Sasaki, Takanori; Takenaka, Fumiaki; Yakushiji, Hiromasa; Fujii, Yoshihiro; Kishi, Yoshiro; Kita, Shoichi; Shen, Lianhua; Kumon, Hiromi; Matsuura, Eiji

    2015-01-01

    Mesothelin (MSLN) is a 40-kDa cell differentiation-associated glycoprotein appearing with carcinogenesis and is highly expressed in many human cancers, including the majority of pancreatic adenocarcinomas, ovarian cancers, and mesotheliomas, while its expression in normal tissue is limited to mesothelial cells lining the pleura, pericardium, and peritoneum. Clone 11-25 is a murine hybridoma secreting monoclonal antibody (mAb) against human MSLN. In this study, we applied the 11-25 mAb to in vivo imaging to detect MSLN-expressing tumors. In in vitro and ex vivo immunochemical studies, we demonstrated specificity of 11-25 mAb to membranous MSLN expressed on several pancreatic cancer cells. We showed the accumulation of Alexa Fluor 750-labeled 11-25 mAb in MSLN-expressing tumor xenografts in athymic nude mice. Then, 11-25 mAb was labeled with 64Cu via a chelating agent DOTA and was used in both in vitro cell binding assay and in vivo positron emission tomography (PET) imaging in the tumor-bearing mice. We confirmed that 64Cu-labeled 11-25 mAb highly accumulated in MSLN-expressing tumors as compared to MSLN-negative ones. The 64Cu-labeled 11-25 mAb is potentially useful as a PET probe capable of being used for wide range of tumors, rather than 18F-FDG that occasionally provides nonspecific accumulation into the inflammatory lesions. PMID:25883990

  12. Impact of toxigenic Clostridium difficile polymerase chain reaction testing on the clinical microbiology laboratory and inpatient epidemiology.

    PubMed

    Napierala, Maureen; Munson, Erik; Skonieczny, Patrice; Rodriguez, Sonia; Riederer, Nancy; Land, Gayle; Luzinski, Mary; Block, Denise; Hryciuk, Jeanne E

    2013-08-01

    Conversion from Clostridium difficile toxin A/B EIA to tcdB polymerase chain reaction for diagnosis of C. difficile infection (CDI) resulted in significant decreases in laboratory testing volume and largely unchanged C. difficile toxin detection rates. Decreases in healthcare-associated CDI rates (P ≤ 0.05) reflected a clinical practice benefit of this conversion. Copyright © 2013 Elsevier Inc. All rights reserved.

  13. Rapid enzyme immunoassay for determination of toxigenicity among clinical isolates of corynebacteria.

    PubMed

    Engler, K H; Efstratiou, A

    2000-04-01

    A rapid enzyme immunoassay (EIA) was developed for the phenotypic detection of diphtheria toxin among clinical isolates of corynebacteria. The assay uses equine polyclonal antitoxin as the capture antibody and an alkaline phosphatase-labeled monoclonal antibody, specific for fragment A of the toxin molecule, as the detecting antibody. The assay is rapid, sensitive, and specific: a final result is available within 3 h of colony selection, and the limits of detection are 0.1 ng of pure diphtheria toxin/ml. Toxigenicity could be detected with isolates grown on a diverse range of culture media, including selective agars. Toxin detection using the EIA was compared to that with the Elek test and PCR detection of fragment A of the diphtheria toxin (tox) gene, using 245 isolates of corynebacteria. The results for the EIA were in complete concordance with those of the Elek test: 87 toxigenic and 158 nontoxigenic isolates. Ten of the phenotypically nontoxigenic strains were found to contain fragment A of the tox gene but did not express the toxin protein. These isolates were found to be nontoxigenic in the Vero cell tissue culture cytotoxicity assay and were therefore nontoxigenic for diagnostic purposes. The EIA is a simple rapid phenotypic test which provides a definitive result on toxigenicity within one working day.

  14. Rapid Enzyme Immunoassay for Determination of Toxigenicity among Clinical Isolates of Corynebacteria

    PubMed Central

    Engler, Kathryn H.; Efstratiou, Androulla

    2000-01-01

    A rapid enzyme immunoassay (EIA) was developed for the phenotypic detection of diphtheria toxin among clinical isolates of corynebacteria. The assay uses equine polyclonal antitoxin as the capture antibody and an alkaline phosphatase-labeled monoclonal antibody, specific for fragment A of the toxin molecule, as the detecting antibody. The assay is rapid, sensitive, and specific: a final result is available within 3 h of colony selection, and the limits of detection are 0.1 ng of pure diphtheria toxin/ml. Toxigenicity could be detected with isolates grown on a diverse range of culture media, including selective agars. Toxin detection using the EIA was compared to that with the Elek test and PCR detection of fragment A of the diphtheria toxin (tox) gene, using 245 isolates of corynebacteria. The results for the EIA were in complete concordance with those of the Elek test: 87 toxigenic and 158 nontoxigenic isolates. Ten of the phenotypically nontoxigenic strains were found to contain fragment A of the tox gene but did not express the toxin protein. These isolates were found to be nontoxigenic in the Vero cell tissue culture cytotoxicity assay and were therefore nontoxigenic for diagnostic purposes. The EIA is a simple rapid phenotypic test which provides a definitive result on toxigenicity within one working day. PMID:10747112

  15. Genetic labelling and application of the isoproturon-mineralizing Sphingomonas sp. strain SRS2 in soil and rhizosphere.

    PubMed

    Kristensen, K E; Jacobsen, C S; Hansen, L H; Aamand, J; Morgan, J A W; Sternberg, C; Sørensen, S R

    2006-09-01

    To construct a luxAB-labelled Sphingomonas sp. strain SRS2 maintaining the ability to mineralize the herbicide isoproturon and usable for monitoring the survival and distribution of strain SRS2 on plant roots in laboratory systems. We inserted the mini-Tn5-luxAB marker into strain SRS2 using conjugational mating. In the transconjugant mutants luciferase was produced in varying levels. The mutants showed significant differences in their ability to degrade isoproturon. One luxAB-labelled mutant maintained the ability to mineralize isoproturon and was therefore selected for monitoring colonization of barley roots. We successfully constructed a genetically labelled isoproturon-mineralizing-strain SRS2 and demonstrated its ability to survive in soil and its colonization of rhizosphere. The construction of a luxAB-labelled strain SRS2 maintaining the degradative ability, provides a powerful tool for ecological studies serving as the basis for evaluating SRS2 as a bioremediation agent.

  16. Biodistribution of iodine-125 and indium-111 labeled OV-TL 3 intact antibodies and F(ab')2 fragments in tumor-bearing athymic mice.

    PubMed

    Massuger, L F; Boerman, O C; Corstens, F H; Verheijen, R H; Claessens, R A; Poels, L G; van den Broek, W J; Kenemans, P

    1991-01-01

    The monoclonal antibody OV-TL 3, directed against an ovarian carcinoma-associated antigenic determinant, was tested as a vehicle for radioimmunolocalization of ovarian carcinomas in athymic mice bearing NIH:OVCAR-3 xenografts. The biodistribution of intact. OV-TL 3 was compared with the distribution of OC 125. Tumor uptake with OV-TL 3 was significantly higher than with OC 125, and almost 7 times higher than with a non-specific control antibody (OV-TL 19). Administration of a mixture of intact OV-TL 3 and OC 125 did not improve tumor uptake in comparison with OV-TL 3 alone. Subsequently, intact OV-TL 3 and its F(ab')2 fragments were labeled with either 111In or 125I. The highest tumor uptake was obtained with 111In-labeled intact OV-TL 3 (14.7% ID/g, 48 hr p.i.). For both antibody forms uptake of 111In in liver, spleen and kidneys was very high. Furthermore, 111In cleared more slowly from most tissues than 125I. As a result, tumor/tissue ratios with 111In-labeled OV-TL 3 were lower than with 125I-labeled OV-TL 3. The highest tumor/tissue ratios (6.9 to 53) were obtained with 125I-labeled OV-TL 3 F(ab')2 fragments, 48 hr post injection. 111In-labeled OV-TL 3 F(ab')2 has already been shown to be a clinically useful label for the detection of ovarian cancer. The results of our comparative animal study suggest that these clinical results may even be improved by using 123I-labeled OV-TL 3 F(ab')2.

  17. SIB-DOTA: a trifunctional prosthetic group potentially amenable for multi-modal labeling that enhances tumor uptake of internalizing monoclonal antibodies.

    PubMed

    Vaidyanathan, G; White, B J; Affleck, D J; Zhao, X G; Welsh, P C; McDougald, D; Choi, J; Zalutsky, M R

    2012-12-15

    A major drawback of internalizing monoclonal antibodies (mAbs) radioiodinated with direct electrophilic approaches is that tumor retention of radioactivity is compromised by the rapid washout of iodo-tyrosine, the primary labeled catabolite for mAbs labeled via this strategy. In our continuing efforts to develop more versatile residualizing labels that could overcome this problem, we have designed SIB-DOTA, a prosthetic labeling template that combines the features of the prototypical, dehalogenation-resistant N-succinimidyl 3-iodobenzoate (SIB) with DOTA, a useful macrocyclic chelator for labeling with radiometals. Herein we describe the synthesis of the unlabeled standard of this prosthetic moiety, its protected tin precursor, and radioiodinated SIB-DOTA. An anti-EGFRvIII-reactive mAb, L8A4 was radiolabeled with [(131)I]SIB-DOTA in 27.1±6.2% (n=2) conjugation yields and its targeting properties to the same mAb labeled with [(125)I]SGMIB both in vitro and in vivo using U87MG·ΔEGFR cells and xenografts were compared. In vitro paired-label internalization assays showed that the intracellular radioactivity from [(131)I]SIB-DOTA-L8A4 was 21.4±0.5% and 26.2±1.1% of initially bound radioactivity at 16 and 24h, respectively. In comparison, these values for [(125)I]SGMIB-L8A4 were 16.7±0.5% and 14.9±1.1%. Similarly, the SIB-DOTA prosthetic group provided better tumor targeting in vivo than SGMIB over 8 d period. These results suggest that SIB-DOTA warrants further evaluation as a residualizing agent for labeling internalizing mAbs including those targeted to EGFRvIII. Copyright © 2012 Elsevier Ltd. All rights reserved.

  18. Quantitative assessment of antibody internalization with novel monoclonal antibodies against Alexa fluorophores.

    PubMed

    Liao-Chan, Sindy; Daine-Matsuoka, Barbara; Heald, Nathan; Wong, Tiffany; Lin, Tracey; Cai, Allen G; Lai, Michelle; D'Alessio, Joseph A; Theunissen, Jan-Willem

    2015-01-01

    Antibodies against cell surface antigens may be internalized through their specific interactions with these proteins and in some cases may induce or perturb antigen internalization. The anti-cancer efficacy of antibody-drug conjugates is thought to rely on their uptake by cancer cells expressing the surface antigen. Numerous techniques, including microscopy and flow cytometry, have been used to identify antibodies with desired cellular uptake rates. To enable quantitative measurements of internalization of labeled antibodies, an assay based on internalized and quenched fluorescence was developed. For this approach, we generated novel anti-Alexa Fluor monoclonal antibodies (mAbs) that effectively and specifically quench cell surface-bound Alexa Fluor 488 or Alexa Fluor 594 fluorescence. Utilizing Alexa Fluor-labeled mAbs against the EphA2 receptor tyrosine kinase, we showed that the anti-Alexa Fluor reagents could be used to monitor internalization quantitatively over time. The anti-Alexa Fluor mAbs were also validated in a proof of concept dual-label internalization assay with simultaneous exposure of cells to two different mAbs. Importantly, the unique anti-Alexa Fluor mAbs described here may also enable other single- and dual-label experiments, including label detection and signal enhancement in macromolecules, trafficking of proteins and microorganisms, and cell migration and morphology.

  19. Immunogenetic Mechanisms Driving Norovirus GII.4 Antigenic Variation

    PubMed Central

    Donaldson, Eric F.; Corti, Davide; Swanstrom, Jesica; Debbink, Kari; Lanzavecchia, Antonio; Baric, Ralph S.

    2012-01-01

    Noroviruses are the principal cause of epidemic gastroenteritis worldwide with GII.4 strains accounting for 80% of infections. The major capsid protein of GII.4 strains is evolving rapidly, resulting in new epidemic strains with altered antigenic potentials. To test if antigenic drift may contribute to GII.4 persistence, human memory B cells were immortalized and the resulting human monoclonal antibodies (mAbs) characterized for reactivity to a panel of time-ordered GII.4 virus-like particles (VLPs). Reflecting the complex exposure history of the volunteer, human anti-GII.4 mAbs grouped into three VLP reactivity patterns; ancestral (1987–1997), contemporary (2004–2009), and broad (1987–2009). NVB 114 reacted exclusively to the earliest GII.4 VLPs by EIA and blockade. NVB 97 specifically bound and blocked only contemporary GII.4 VLPs, while NBV 111 and 43.9 exclusively reacted with and blocked variants of the GII.4.2006 Minerva strain. Three mAbs had broad GII.4 reactivity. Two, NVB 37.10 and 61.3, also detected other genogroup II VLPs by EIA but did not block any VLP interactions with carbohydrate ligands. NVB 71.4 cross-neutralized the panel of time-ordered GII.4 VLPs, as measured by VLP-carbohydrate blockade assays. Using mutant VLPs designed to alter predicted antigenic epitopes, two evolving, GII.4-specific, blockade epitopes were mapped. Amino acids 294–298 and 368–372 were required for binding NVB 114, 111 and 43.9 mAbs. Amino acids 393–395 were essential for binding NVB 97, supporting earlier correlations between antibody blockade escape and carbohydrate binding variation. These data inform VLP vaccine design, provide a strategy for expanding the cross-blockade potential of chimeric VLP vaccines, and identify an antibody with broadly neutralizing therapeutic potential for the treatment of human disease. Moreover, these data support the hypothesis that GII.4 norovirus evolution is heavily influenced by antigenic variation of neutralizing epitopes and consequently, antibody-driven receptor switching; thus, protective herd immunity is a driving force in norovirus molecular evolution. PMID:22615565

  20. Performance of the BioPlex 2200 HIV Ag-Ab assay for identifying acute HIV infection.

    PubMed

    Eshleman, Susan H; Piwowar-Manning, Estelle; Sivay, Mariya V; Debevec, Barbara; Veater, Stephanie; McKinstry, Laura; Bekker, Linda-Gail; Mannheimer, Sharon; Grant, Robert M; Chesney, Margaret A; Coates, Thomas J; Koblin, Beryl A; Fogel, Jessica M

    Assays that detect HIV antigen (Ag) and antibody (Ab) can be used to screen for HIV infection. To compare the performance of the BioPlex 2200 HIV Ag-Ab assay and two other Ag/Ab combination assays for detection of acute HIV infection. Samples were obtained from 24 individuals (18 from the US, 6 from South Africa); these individuals were classified as having acute infection based on the following criteria: positive qualitative RNA assay; two negative rapid tests; negative discriminatory test. The samples were tested with the BioPlex assay, the ARCHITECT HIV Ag/Ab Combo test, the Bio-Rad GS HIV Combo Ag-Ab EIA test, and a viral load assay. Twelve (50.0%) of 24 samples had RNA detected only ( > 40 to 13,476 copies/mL). Ten (43.5%) samples had reactive results with all three Ag/Ab assays, one sample was reactive with the ARCHITECT and Bio-Rad assays, and one sample was reactive with the Bio-Rad and BioPlex assays. The 11 samples that were reactive with the BioPlex assay had viral loads from 83,010 to >750,000 copies/mL; 9/11 samples were classified as Ag positive/Ab negative by the BioPlex assay. Detection of acute HIV infection was similar for the BioPlex assay and two other Ag/Ab assays. All three tests were less sensitive than a qualitative RNA assay and only detected HIV Ag when the viral load was high. The BioPlex assay detected acute infection in about half of the cases, and identified most of those infections as Ag positive/Ab negative. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Determination of autoantibodies to thyroglobulin, thyroxine and triiodothyronine in canine serum.

    PubMed

    Patzl, M; Möstl, E

    2003-03-01

    Enzyme immunoassays (EIAs) for the determination of autoanti-bodies (AA) to thyroid antigens in canine serum were developed. Streptavidin (SA) was immobilized as capture molecule on microtitreplates (MTP). Thyroglobulin (Tg) purified from canine thyroids and the thyroid hormones thyroxine and triiodothyronine (T3 and T4) were conjugated to biotin labelling reagents and attached to the MTP over the SA-biotin bridge. Bound AA were detected with anti-dog-immunoglobulin G (IgG) labelled with horseradish peroxidase. Serum samples from dogs which were allotted to four groups were analysed: A (n = 31), biochemical evidence of hypothyroidism; B (n = 76), clinical signs of hypothyroidism; C (n = 47), euthyroid with non-thyroidal disease; D (n = 186), clinically healthy. The validity of the assays was tested with two different methods. After thiophilic absorption chromatography of positive sera, a positive reaction in the EIA was only detected in those fractions which coeluted with the canine IgG standard. Furthermore, the positive reaction was blocked by the addition of the corresponding antigen. In 55% of the hypothyroid dogs AA to Tg and/or T3 and T4, respectively, were found (up to a titre of 1 : 1600). In group B 34% of the dogs were diagnosed positive, but the titre was lower (up to 1 : 400). In the groups C and D the number of dogs with AA and their titre was significantly lower. Two different methods for distinguishing positive and negative test results were compared in order to increase the specificity of the tests without decreasing the sensitivity. The EIAs are precise and based on high agreement with previous reported assays able to discriminate dogs with thyroiditis from healthy ones. These assays represent a good alternative to the isotope assays generally used for the analysis of AA to T4 and T3.

  2. Multicapillary SDS-gel electrophoresis for the analysis of fluorescently labeled mAb preparations: a high throughput quality control process for the production of QuantiPlasma and PlasmaScan mAb libraries.

    PubMed

    Székely, Andrea; Szekrényes, Akos; Kerékgyártó, Márta; Balogh, Attila; Kádas, János; Lázár, József; Guttman, András; Kurucz, István; Takács, László

    2014-08-01

    Molecular heterogeneity of mAb preparations is the result of various co- and post-translational modifications and to contaminants related to the production process. Changes in molecular composition results in alterations of functional performance, therefore quality control and validation of therapeutic or diagnostic protein products is essential. A special case is the consistent production of mAb libraries (QuantiPlasma™ and PlasmaScan™) for proteome profiling, quality control of which represents a challenge because of high number of mAbs (>1000). Here, we devise a generally applicable multicapillary SDS-gel electrophoresis process for the analysis of fluorescently labeled mAb preparations for the high throughput quality control of mAbs of the QuantiPlasma™ and PlasmaScan™ libraries. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Multi-centre field evaluation of the performance of the Trinity Biotech Uni-Gold HIV 1/2 rapid test as a first-line screening assay for gay and bisexual men compared with 4th generation laboratory immunoassays.

    PubMed

    Keen, P; Conway, D P; Cunningham, P; McNulty, A; Couldwell, D L; Davies, S C; Smith, D E; Gray, J; Holt, M; O'Connor, C C; Read, P; Callander, D; Prestage, G; Guy, R

    2017-01-01

    The Trinity Biotech Uni-Gold HIV test (Uni-Gold) is often used as a supplementary rapid test in testing algorithms. To evaluate the operational performance of the Uni-Gold as a first-line screening test among gay and bisexual men (GBM) in a setting where 4th generation HIV laboratory assays are routinely used. We compared the performance of Uni-Gold with conventional HIV serology conducted in parallel among GBM attending 22 testing sites. Sensitivity was calculated separately for acute and established infection, defined using 4th generation screening Ag/Ab immunoassay (EIA) and Western blot results. Previous HIV testing history and results of supplementary 3rd generation HIV Ab EIA, and p24 antigen EIA were used to further characterise cases of acute infection. Of 10,793 specimens tested with Uni-Gold and conventional serology, 94 (0.90%, 95%CI:0.70-1.07) were confirmed as HIV-positive by conventional serology, and 37 (39.4%) were classified as acute infection. Uni-Gold sensitivity was 81.9% overall (77/94, 95%CI:72.6-89.1); 56.8% for acute infection (21/37, 95%CI:39.5-72.9) and 98.2% for established infection (56/57, 95%CI:90.6-100.0). Of 17 false non-reactive Uni-Gold results, 16 were acute infections, and of these seven were p24 antigen reactive but antibody negative. Uni-Gold specificity was 99.9% (10,692/10,699, 95%CI:99.9-100.0), PPV was 91.7% (95%CI:83.6-96.6) and NPV was 99.8% (95%CI:99.7-99.9), respectively. In this population, Uni-Gold had good specificity and sensitivity was high for established infections when compared to 4th generation laboratory assays, however sensitivity was lower in acute infections. Where rapid tests are used in populations with a high proportion of acute infections, additional testing strategies are needed to detect acute infections. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. A highly sensitive capillary electrophoresis immunoassay strategy based on dual-labeled gold nanoparticles enhancing chemiluminescence for the detection of prostate-specific antigen.

    PubMed

    Li, Shuting; Shi, Min; Zhao, Jingjin; Zhang, Liangliang; Huang, Yong; Zhao, Shulin

    2017-07-01

    An enzyme and antibody dual labeled gold nanoparticles enhancing chemiluminescence strategy was developed for highly sensitive CE immunoassay (IA) of prostate-specific antigen (PSA). In this work, gold nanoparticles were labeled with horseradish peroxidase and antiprostate specific antigen-antibody, and used as the marker (Ab * ). After PSA (antigen, Ag) was added into the system, a noncompetitive immune reaction was happen between Ab * and Ag to form an immune complex (Ag-Ab * ). Subsequently, the obtained Ag-Ab * and unreacted Ab * were separated by CE, and the chemiluminescence intensity of Ag-Ab * was used to estimate PSA concentration. The calibration curve showed a good linearity in the range of 0.25-10 ng/mL. Based on a S/N of 3, the detection limit for PAS was estimated to be 0.092 ng/mL. Proposed CE method was applied for PSA quantification in human serum samples from healthy volunteers and patients with prostate cancer. The obtained results demonstrated that the proposed CE method may serve as an alternative tool for clinical analysis of PSA. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Localized conformational interrogation of antibody and antibody-drug conjugates by site-specific carboxyl group footprinting.

    PubMed

    Pan, Lucy Yan; Salas-Solano, Oscar; Valliere-Douglass, John F

    Establishing and maintaining conformational integrity of monoclonal antibodies (mAbs) and antibody-drug conjugates (ADCs) during development and manufacturing is critical for ensuring their clinical efficacy. As presented here, we applied site-specific carboxyl group footprinting (CGF) for localized conformational interrogation of mAbs. The approach relies on covalent labeling that introduces glycine ethyl ester tags onto solvent-accessible side chains of protein carboxylates. Peptide mapping is used to monitor the labeling kinetics of carboxyl residues and the labeling kinetics reflects the conformation or solvent-accessibility of side chains. Our results for two case studies are shown here. The first study was aimed at defining the conformational changes of mAbs induced by deglycosylation. We found that two residues in C H 2 domain (D268 and E297) show significantly enhanced side chain accessibility upon deglycosylation. This site-specific result highlighted the advantage of monitoring the labeling kinetics at the amino acid level as opposed to the peptide level, which would result in averaging out of highly localized conformational differences. The second study was designed to assess conformational effects brought on by conjugation of mAbs with drug-linkers. All 59 monitored carboxyl residues displayed similar solvent-accessibility between the ADC and mAb under native conditions, which suggests the ADC and mAb share similar side chain conformation. The findings are well correlated and complementary with results from other assays. This work illustrated that site-specific CGF is capable of pinpointing local conformational changes in mAbs or ADCs that might arise during development and manufacturing. The methodology can be readily implemented within the industry to provide comprehensive conformational assessment of these molecules.

  6. Comparison of (99m)Tc-labeled PR81 and its F(ab')₂ fragments as radioimmunoscintigraphy agents for breast cancer imaging.

    PubMed

    Salouti, Mojtaba; Babaei, Mohammad Hossein; Rajabi, Hossein; Foroutan, Haleh; Rasaee, Mohammad Javad; Rajabi, Ahmad Bitarafan; Mohammadnejad, Javad; Shafiee, Mohammad; Mazidi, Mohammad; Daha, Fariba Johari

    2011-02-01

    We digested anti-MUC1 monoclonal antibody PR81 to produce F(ab')₂ fragments. A comparison was performed between the two radiolabeled PR81 and F(ab')₂ fragments for breast tumor imaging in a mouse model. The optimum conditions for pepsin digestion of PR81 were investigated in terms of enzymes: antibody ratio, digestion time duration and preserved immunoreactivity of the produced fragments. The F(ab')₂ fragments were labeled with Technetium-99m using HYNIC as a chelator and tricine as a co-ligand. The immunoreactivity of the complexes was assessed by radioimmunoassay using MCF7 cells. Biodistribution and imaging studies were performed in female BALB/c mice with breast tumor xenograft at 4, 8 and 24 h post-administration. The PR81 was labeled with technetium-99m in the same way for comparison. The optimum time duration for PR81 digestion was found to be 28 h at an enzyme:antibody weight ratio of 1:20 that resulted in 95.2 ± 4.7% purity. The labeling of intact PR81 and its F(ab')₂ fragments were 87.6 ± 4.2 and 76.1 ± 3.3% after 1 h, respectively (p value <0.05). The percentage of immunoreactivity of F(ab')₂ fragments and intact PR81 were 75.4 ± 2.1% and 85.7 ± 2.9%, respectively (p value <0.05). The biodistribution and imaging studies demonstrated localization of the fragments at 4 h post-administration with high sensitivity and specificity. The results showed that F(ab')₂ fragment of PR81 is more suitable than intact PR81 for safer and more rapid detection of human breast cancer.

  7. Altered antigenicity of human monoclonal antibodies derived from human-mouse heterohybridomas.

    PubMed

    Kan-Mitchell, J; Andrews, K L; Gallardo, D; Mitchell, M S

    1987-04-01

    We have generated milligram quantities of human monoclonal antibodies (Hu-MAbs) in the ascites of pristane-primed nude mice injected with human-mouse heterohybridomas. After contaminating mouse immunoglobulins were removed by affinity chromatography, an enzyme immunosorbent assay (EIA) was used to measure the concentrations of human immunoglobulins. Ten different partially purified preparations were tested. The titration curves with all 5 IgG Hu-MAbs were unusual, reaching a plateau at a very low apparent maximum concentration of antibody. In contrast, the EIA yielded more usual titration curves and thus apparently more reliable estimates of the concentrations of 4 IgM and 1 IgA monoclonal antibodies. An analogous EIA for the quantitation of mouse IgG monoclonal antibodies also gave accurate estimates. To understand the nature of the discrepancy with human IgG, 5 Hu-MAbs of the 3 classes (2 IgG, 2 pentameric IgM and 1 IgA) were purified to homogeneity for a more detailed analysis. The inability to quantitate the human IgG monoclonal antibodies by EIA was not due to defective molecules, as shown by SDS polyacrylamide gel electrophoresis. The human IgG monoclonal antibodies were found to consist of intact heavy and light chains, as were the IgM and IgA antibodies. The possibility that the human IgG monoclonal antibodies differed antigenically from polyclonal IgG was explored by comparing the concentrations by EIA with the protein concentrations determined by absorbance at 280 nm. This analysis permitted a comparison of the detectability of antigenic determinants on Hu-MAbs with those on polyclonal Ig with goat antibodies to Ig or Ig subclass. The IgG monoclonal antibodies differed from polyclonal IgG in both their heavy and light chains. Goat antiserum monospecific for the gamma chain in fact underestimated the concentration by as much as one hundred-fold. IgM and IgA monoclonal antibodies were less antigenically distinct from their polyclonal counterparts even though their light chains were also underestimated, because goat monospecific antibodies were more efficient at recognizing their heavy chains. The molecular basis for the observed difference in antigenicity is not yet known. These findings have important implications for the analysis of the binding of IgG Hu-MAbs. A direct binding assay with the label directly conjugated to the Hu-MAb should be used in preference to an indirect assay with a labeled detecting antibody to maximize the sensitivity of the assay. The altered antigenicity of IgG Hu-MAbs may also imply decreased immunogenicity when they are given in vivo as carriers for radionuclides or cytotoxic antitumor materials.

  8. Oriented conjugates of monoclonal and single-domain antibodies with quantum dots for flow cytometry and immunohistochemistry diagnostic applications

    NASA Astrophysics Data System (ADS)

    Sukhanova, Alyona; Even-Desrumeaux, Klervi; Millot, Jean-Marc; Chames, Patrick; Baty, Daniel; Artemyev, Mikhail; Oleinikov, Vladimir; Cohen, Jacques H. M.; Nabiev, Igor

    2012-03-01

    Ideal diagnostic nanoprobes should not exceed 15 nm in size and should contain high-affinity homogeneously oriented capture molecules on their surface. An advanced procedure for antibody (Ab) reduction was used to cleave each Ab into two functional half-Abs, 75-kDa heavy-light chain fragments, each containing an intact antigen-binding site. Affinity purification of half-Abs followed by their linkage to quantum dots (QDs) yielded oriented QD-Ab conjugates whose functionality was considerably improved compared to those obtained using the standard protocols. Ultrasmall diagnostic nanoprobes were engineered through oriented conjugation of QDs with 13-kDa single-domain Abs (sdAbs) derived from llama IgG. sdAbs were tagged with QDs via an additional cysteine residue specifically integrated into the C-terminal region of sdAb using genetic engineering. This approach made it possible to obtain sdAb-QD nanoprobes <12 nm in diameter comprising four copies of sdAbs linked to the same QD in an oriented manner. sdAb-QD conjugates against carcinoembryonic antigen (CEA) and HER2 exhibited an extremely high specificity in flow cytometry; the quality of immunohistochemical labeling of biopsy samples was found to be superior to that of labeling according to the current "gold standard" protocols of anatomo-pathological practice. The nano-bioengineering approaches developed can be extended to oriented conjugation of Abs and sdAbs with different semiconductor, noble metal, or magnetic nanoparticles.

  9. Functionalized gold nanorod-based labels for amplified electrochemical immunoassay of E. coli as indicator bacteria relevant to the quality of dairy product.

    PubMed

    Zhang, Xinai; Zhang, Fan; Zhang, Hongyin; Shen, Jianzhong; Han, En; Dong, Xiaoya

    2015-01-01

    In this paper, we report an amplified electrochemical immunoassay for Escherichia coli as indicator bacteria relevant to the quality of dairy product using the functionalized gold nanorod-based labels ({dAb-AuNR-FCA}). The {dAb-AuNR-FCA} labels were designed by exploiting silica-functionalized gold nanorods (AuNR@SiO2) as the carriers for immobilization of detection antibody (dAb) and ferrocenecarboxylic acid (FCA), in which dAb was used for recognition of E. coli and FCA tags served as signal-generating molecule. Greatly amplified signal was achieved in the sandwich-type immunoassay when enormous FCA linked to AuNR@SiO2. Compared with the commercially available {dAb-FCA}, the {dAb-AuNR-FCA} labels exhibited a better performance for E. coli assay due to the advantages of AuNR@SiO2 as carriers. Under optimal experimental conditions, it showed a linear relationship between the peak current of FCA and the logarithmic value of E. coli concentration ranging from 1.0×10(2) to 5.0×10(4) cfu mL(-1) with a detection limit of 60 cfu mL(-1) (S/N=3), and the electrochemical detection of E. coli could be achieved in 3h. Moreover, the proposed strategy was used to determine E. coli in dairy product (pure fresh milk, yogurt in shelf-life, and expired yogurt), and the recoveries of standard additions were in the range of 95.1-106%. This proposed strategy exhibited rapid response, high sensitivity and specificity for E. coli assay in dairy product, and could become a promising technique to estimate the quality of dairy product. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Comparison of China's Environmental Impact Assessment (EIA) law with the European Union (EU) EIA Directive.

    PubMed

    Chen, Qiaoling; Zhang, Yuanzhi; Ekroos, Ari

    2007-09-01

    In this paper, we first review the development of China's Environmental Impact Assessment (EIA) system in the past 30 years. Then we compare the framework and operational procedures of China's new EIA law with those of the EU EIA Directive. We also compare public participation, as well as sanctions and control in the two EIA systems. In addition, we identify where the processes in both EIA systems are similar or different from one another. By comparison, we noted that there are at least three obvious weaknesses in China's EIA system: (1) the application of new models for EIA legislation; (2) the improvement of EIA guidance and education; and (3) the enhancement of public participation in EIA process. Our study indicates that these three major shortcomings should be overcome and improved in China's EIA system, when compared with the EU EIA system.

  11. Quantitative Analysis of Endocytic Recycling of Membrane Proteins by Monoclonal Antibody-Based Recycling Assays.

    PubMed

    Blagojević Zagorac, Gordana; Mahmutefendić, Hana; Maćešić, Senka; Karleuša, Ljerka; Lučin, Pero

    2017-03-01

    In this report, we present an analysis of several recycling protocols based on labeling of membrane proteins with specific monoclonal antibodies (mAbs). We analyzed recycling of membrane proteins that are internalized by clathrin-dependent endocytosis, represented by the transferrin receptor, and by clathrin-independent endocytosis, represented by the Major Histocompatibility Class I molecules. Cell surface membrane proteins were labeled with mAbs and recycling of mAb:protein complexes was determined by several approaches. Our study demonstrates that direct and indirect detection of recycled mAb:protein complexes at the cell surface underestimate the recycling pool, especially for clathrin-dependent membrane proteins that are rapidly reinternalized after recycling. Recycling protocols based on the capture of recycled mAb:protein complexes require the use of the Alexa Fluor 488 conjugated secondary antibodies or FITC-conjugated secondary antibodies in combination with inhibitors of endosomal acidification and degradation. Finally, protocols based on the capture of recycled proteins that are labeled with Alexa Fluor 488 conjugated primary antibodies and quenching of fluorescence by the anti-Alexa Fluor 488 displayed the same quantitative assessment of recycling as the antibody-capture protocols. J. Cell. Physiol. 232: 463-476, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  12. 77 FR 16671 - Labeling Imported Wines With Multistate Appellations

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-22

    ...-2010-0007; T.D. TTB-101; Re: Notice No. 110] RIN 1513-AB58 Labeling Imported Wines With Multistate.... SUMMARY: The Alcohol and Tobacco Tax and Trade Bureau is amending the wine labeling regulations to allow the labeling of imported wines with multistate appellations of origin. This amendment provides...

  13. 78 FR 18272 - Energy Labeling Rule

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-26

    ... FEDERAL TRADE COMMISSION 16 CFR Part 305 [3084-AB15] Energy Labeling Rule AGENCY: Federal Trade... ``Energy Label Ranges, Matter No. R611004'' on your comment, and file your comment online at https... Commission proposed to amend the Energy Labeling Rule (``Rule'') (16 CFR part 305) by updating ranges of...

  14. CdSe/ZnS Quantum Dot-Labeled Lateral Flow Strips for Rapid and Quantitative Detection of Gastric Cancer Carbohydrate Antigen 72-4

    NASA Astrophysics Data System (ADS)

    Yan, Xinyu; Wang, Kan; Lu, Wenting; Qin, Weijian; Cui, Daxiang; He, Jinghua

    2016-03-01

    Carbohydrate antigen 72-4 (CA72-4) is an important biomarker associated closely with diagnosis and prognosis of early gastric cancer. How to realize quick, sensitive, specific, and quantitative detection of CA72-4 in clinical specimens has become a great requirement. Herein, we reported a CdSe/ZnS quantum dot-labeled lateral flow test strip combined with a charge-coupled device (CCD)-based reader was developed for rapid, sensitive, and quantitative detection of CA72-4. Two mouse monoclonal antibodies (mAbs) against CA72-4 were employed. One of them was coated as a test line, while another mAb was labeled with quantum dots and coated onto conjugate pad. The goat anti-mouse IgG was immobilized as a control line. After sample was added, a sandwich structure was formed with CA72-4 and these two mAbs. The fluorescent signal from quantum dots (QD)-labeled mAb in sandwich structure was related to the amount of detected CA72-4. A CCD-based reader was used to realize quantitative detection of CA72-4. Results showed that developed QD-labeled lateral flow strips to detect CA72-4 biomarker with the sensitivity of 2 IU/mL and 10 min detection time. One hundred sera samples from clinical patients with gastric cancer and healthy people were used to confirm specificity of this strip method; results showed that established strip method own 100 % reproducibility and 100 % specificity compared with Roche electrochemiluminescence assay results. In conclusion, CdSe/ZnS quantum dot-labeled lateral flow strips for detection of CA72-4 could realize rapid, sensitive, and specific detection of clinical samples and could own great potential in clinical translation in near future.

  15. Analysis of the Environmental Impact Assessment (EIA) Directive and the EIA decision in Turkey

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bilgin, Ayla

    The Environmental Impact Assessment (EIA) Directive first entered into force in the United States in 1969, and began to be implemented in many other countries by 1990. The first Environmental Impact Assessment (EIA) Directive in Turkey was published on February 7, 1993, under the Environmental Law No. 2872. The EIA Directive was revised seven times on June 23, 1997, June 6, 2002, December 16, 2003, July 17, 2008, October 3, 2013, and November 25, 2014. Several amendments were made during this process. The first EIA Directive dated 1993 was narrow in scope and its procedure was long, while the amendmentsmore » in 2003, 2008, 2013, and 2014 widened the scope of the EIA, and shortened the EIA assessment procedures. In this study, the amendments to the Turkish EIA Directive were analysed, and their effect on the number of EIA decisions made was addressed. It was concluded that the uncertainties in EIA procedures were removed, procedures were shortened, and as a result, the number of EIA decisions increased thanks to the revisions made in line with harmonisation with European Union (EU) acquis. - Highlights: • Demonstrates the Environmental Impact Assessment practices in Turkey. • Demonstrates the application of the EIA in Turkey by sector. • Demonstrates the amendments of the EIA by-laws in Turkey. • Demonstrates the changes in EIA practices and EIA decisions.« less

  16. 21 CFR 201.150 - Drugs; processing, labeling, or repacking.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... part thereof, from such establishment, become void ab initio if the drug comprising such shipment... ab initio with respect to the person who introduced such shipment or delivery into interstate...

  17. 21 CFR 201.150 - Drugs; processing, labeling, or repacking.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... part thereof, from such establishment, become void ab initio if the drug comprising such shipment... ab initio with respect to the person who introduced such shipment or delivery into interstate...

  18. 21 CFR 201.150 - Drugs; processing, labeling, or repacking.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... part thereof, from such establishment, become void ab initio if the drug comprising such shipment... ab initio with respect to the person who introduced such shipment or delivery into interstate...

  19. 21 CFR 201.150 - Drugs; processing, labeling, or repacking.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... part thereof, from such establishment, become void ab initio if the drug comprising such shipment... ab initio with respect to the person who introduced such shipment or delivery into interstate...

  20. 21 CFR 201.150 - Drugs; processing, labeling, or repacking.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... part thereof, from such establishment, become void ab initio if the drug comprising such shipment... ab initio with respect to the person who introduced such shipment or delivery into interstate...

  1. 78 FR 8362 - Energy Labeling Rule

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-06

    ... FEDERAL TRADE COMMISSION 16 CFR Part 305 RIN 3084-AB15] Energy Labeling Rule AGENCY: Federal Trade... furnace or central air conditioner meets applicable Department of Energy regional efficiency standards..., 20580. SUPPLEMENTARY INFORMATION: I. Background The Commission's Energy Labeling Rule (``Rule'') (16 CFR...

  2. Is EIA part of the wind power planning problem?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smart, Duncan Ewan; Stojanovic, Timothy A., E-mail: tas21@st-andrews.ac.uk; Warren, Charles R.

    2014-11-15

    This research evaluates the importance and effectiveness of Environmental Impact Assessment (EIA) within wind farm planning debates, drawing on insights from case studies in Scotland. Despite general public support for renewable energy on the grounds that it is needed to tackle climate change and implement sustainable development, many proposed wind farms encounter significant resistance. The importance of planning issues and (EIA) processes has arguably been overlooked within recent wind farm social acceptability discourse. Through semi-structured interviews with key stakeholders and textual analysis of EIA documents, the characteristics of EIA are assessed in terms of its perceived purpose and performance. Themore » data show that whilst respondents perceive EIA to be important, they express concerns about bias and about the inability of EIA to address climate change and wind farm decommissioning issues adequately. Furthermore, the research identifies key issues which impede the effectiveness of EIA, and reveals differences between theoretical and practical framings of EIA. The paper questions the assumption that EIA is a universally applicable tool, and argues that its effectiveness should be analysed in the context of specific development sectors. The article concludes by reviewing whether the recently amended EIA Directive (2014/52/EU) could resolve identified problems within national EIA practice. - Highlights: • Evaluation of EIA for onshore wind farm planning in Scotland. • EIA is important for multiple aspects of onshore wind farm planning. • Multiple substantive deficiencies of relevance to wind farm planning exist in EIA. • Further research into EIA effectiveness for specific development types is required. • Directive 2014/52/EU may improve EIA effectiveness within wind farm planning.« less

  3. Fluorine-18 labeling of an anti-HER2 VHH using a residualizing prosthetic group via a strain-promoted click reaction: Chemistry and preliminary evaluation.

    PubMed

    Zhou, Zhengyuan; Chitneni, Satish K; Devoogdt, Nick; Zalutsky, Michael R; Vaidyanathan, Ganesan

    2018-05-01

    In a previous study, we evaluated a HER2-specific single domain antibody fragment (sdAb) 2Rs15d labeled with 18 F via conjugation of a residualizing prosthetic agent that was synthesized by copper-catalyzed azide-alkyne cycloaddition (CuAAC). In order to potentially increase overall efficiency and decrease the time required for labeling, we now investigate the use of a strain-promoted azide-alkyne cycloaddition (SPAAC) between the 2Rs15d sdAb, which had been pre-derivatized with an azide-containing residualizing moiety, and an 18 F-labeled aza-dibenzocyclooctyne derivative. The HER2-targeted sdAb 2Rs15d and a nonspecific sdAb R3B23 were pre-conjugated with a moiety containing both azide- and guanidine functionalities. The thus derivatized sdAbs were radiolabeled with 18 F using an 18 F-labeled aza-dibenzocyclooctyne derivative ([ 18 F]F-ADIBO) via SPAAC, generating the desired conjugate ([ 18 F]RL-II-sdAb). For comparison, unmodified 2Rs15d was labeled with N-succinimidyl 4-guanidinomethyl-3-[ 125 I]iodobenzoate ([ 125 I]SGMIB), the prototypical residualizing agent for radioiodination. Radiochemical purity (RCP), immunoreactive fraction (IRF), HER2-binding affinity and cellular uptake of [ 18 F]RL-II-2Rs15d were assessed in vitro. Paired label biodistribution of [ 18 F]RL-II-2Rs15d and [ 125 I]SGMIB-2Rs15d, and microPET/CT imaging of [ 18 F]RL-II-2Rs15d and the [ 18 F]RL-II-R3B23 control sdAb were performed in nude mice bearing HER2-expressing SKOV-3 xenografts. A radiochemical yield of 23.9 ± 6.9% (n = 8) was achieved for the SPAAC reaction between [ 18 F]F-ADIBO and azide-modified 2Rs15d and the RCP of the labeled sdAb was >95%. The affinity (K d ) and IRF for the binding of [ 18 F]RL-II-2Rs15d to HER2 were 5.6 ± 1.3 nM and 73.1 ± 22.5% (n = 3), respectively. The specific uptake of [ 18 F]RL-II-2Rs15d by HER2-expressing BT474M1 breast carcinoma cells in vitro was 14-17% of the input dose at 1, 2, and 4 h, slightly higher than seen for co-incubated [ 125 I]SGMIB-2Rs15d. The uptake of [ 18 F]RL-II-2Rs15d in SKOV-3 xenografts at 1 h and 2 h p.i. were 5.54 ± 0.77% ID/g and 6.42 ± 1.70% ID/g, respectively, slightly higher than those for co-administered [ 125 I]SGMIB-2Rs15d (4.80 ± 0.78% ID/g and 4.78 ± 1.39% ID/g). MicroPET/CT imaging with [ 18 F]RL-II-2Rs15d at 1-3 h p.i. clearly delineated SKOV-3 tumors while no significant accumulation of activity in tumor was seen for [ 18 F]RL-II-R3B23. With the exception of kidneys, normal tissue levels for [ 18 F]RL-II-2Rs15d were low and cleared rapidly. To our knowledge, this is the first time SPAAC method has been used to label an sdAb with 18 F, especially with residualizing functionality. Copyright © 2018 Elsevier Ltd. All rights reserved.

  4. Sensitive electrochemical immunosensor for α-synuclein based on dual signal amplification using PAMAM dendrimer-encapsulated Au and enhanced gold nanoparticle labels.

    PubMed

    An, Yarui; Jiang, Xiaoli; Bi, Wenji; Chen, Hua; Jin, Litong; Zhang, Shengping; Wang, Chuangui; Zhang, Wen

    2012-02-15

    A novel electrochemical immunosensor for sensitive detection of α-synuclein (α-SYN), a very important neuronal protein, has been developed based on dual signal amplification strategy. Herein, G4-polyamidoamine dendrimer-encapsulated Au nanoparticles (PAMAM-Au nanocomposites) were covalently bound on the poly-o-aminobenzoic acid (poly-o-ABA), which was initially electropolymerized on the electrode surface to perform abundant carboxyl groups. The formed immunosensor platform, PAMAM-Au, was proved to provide numerous amino groups to allow highly dense immobilization of antigen, and facilitate the improvement of electrochemical responses as well. Subsequently, the enhanced gold nanoparticle labels ({HRP-Ab(2)-GNPs}) were fabricated by immobilizing horseradish peroxidase-secondary antibody (HRP-Ab(2)) on the surface of gold nanoparticles (GNPs). After an immunoassay process, the {HRP-Ab(2)-GNPs} labels were introduced onto the electrode surface, and produced an electrocatalytic response by reduction of hydrogen peroxide (H(2)O(2)) in the presence of enzymatically oxidized thionine. On the basis of the dual signal amplification of PAMAM-Au and {HRP-Ab(2)-GNPs} labels, the designed immunosensor displayed an excellent analytical performance with high sensitivity and stability. This developed strategy was successfully proved as a simple, cost-effective method, and could be easily extended to other protein analysis schemes. Copyright © 2011 Elsevier B.V. All rights reserved.

  5. 75 FR 67663 - Labeling Imported Wines With Multistate Appellations (2008R-265P)

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-03

    ...-2010-0007; Notice No. 110] RIN 1513-AB58 Labeling Imported Wines With Multistate Appellations (2008R.... SUMMARY: The Alcohol and Tobacco Tax and Trade Bureau proposes to amend the wine labeling regulations to allow the labeling of imported wines with multistate appellations of origin. This amendment would...

  6. Environmental impact assessment system in Thailand and its comparison with those in China and Japan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Suwanteep, Kultip, E-mail: suwanteep.k.aa@m.titech.ac.jp; Murayama, Takehiko; Nishikizawa, Shigeo

    This paper aims to find ways to streamline the Environmental Impact Assessment (EIA) system in Thailand to increase its effectiveness by comparative analysis with China and Japan. This study is mainly focused on review, update and comparison of EIA systems between these three countries. It is intended to clarify fundamental information of the EIA systems and characteristics of the key elements of EIA processes (screening, consideration of alternatives, prediction or evaluation of impact, and public participation). Moreover, the number of the EIA projects that have been implemented in all the provinces in Thailand are presented. The results identified the similaritiesmore » and differences of the EIA processes among the three aforementioned countries. The type of EIA report used in Thailand, unlike those in China and Japan, is an Environmental and Health Impact Assessment (EHIA), which is concerned with the health and environmental impacts that could occur from the project. In addition, EIA reports in Thailand are made available to the public online and the shortcomings of the process have details of barriers resulting from the projects to help future projects with reconsideration and improvements. In this study, it is pointed out that Thai's EIA system still lacks local EIA authority which needs to be empowered by implementing a set of laws or ordinance. - Highlights: • Reviewed current EIA procedures in Thailand, Japan and China • The EIA database is getting improved so as to generate profile of EIAs in the past. • Thailand needs to empower the local EIA authority within the EIA system. • The potential impacts should be more concerned than their scale in Japanese EIA. • Time limits and transparency should be reconsidered in China's EIA system.« less

  7. 21 CFR 701.9 - Exemptions from labeling requirements.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ..., become void ab initio if the cosmetic comprising such shipment, delivery, or part is adulterated or... a cosmetic under paragraph (a)(2) of this section shall become void ab initio with respect to the...

  8. Evaluation of environmental impact assessment system in Pakistan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nadeem, Obaidullah; Hameed, Rizwan

    2008-11-15

    Environmental impact assessment (EIA) was first introduced in Pakistan based on the Environmental Protection Ordinance 1983. The EIA process was further strengthened under the Pakistan Environmental Protection Act 1997, which became operational under EIA Regulations 2000. Despite a sound legal basis and comprehensive guidelines, evidence suggests that EIA has not yet evolved satisfactorily in Pakistan. An evaluation of the EIA system against systematic evaluation criteria, based on interviews with EIA approval authorities, consulting firms and experts, reveals various shortcomings of the EIA system. These mainly include; inadequate capacity of EIA approval authorities, deficiencies in screening and scoping, poor EIA quality,more » inadequate public participation and weak monitoring. Overall, EIA is used presently as a project justification tool rather than as a project planning tool to contribute to achieving sustainable development. Whilst shortcomings are challenging, central government has recently shown a high degree of commitment to the environmental protection by making EIA compulsory for all the public sector projects likely to have adverse environmental impacts. The paper identifies opportunities for taking advantage of the current environment for strengthening the EIA process.« less

  9. An assessment of EIA system in India

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Panigrahi, Jitendra K., E-mail: Jitu@scientist.com; Amirapu, Susruta, E-mail: susrutaa@gmail.com

    Environmental impact assessment (EIA) was first introduced in India based on the Environmental Protection Act (EPA), 1986. But formally it came in to effect, when Ministry of Environment and Forest (MoEF) has passed a major legislative measure under EPA in January 1994 for Environmental Clearance (EC) known as EIA Notification, 1994. Subsequently, EIA processes have been strengthened by MoEF by a series of amendments. The current practice is adhering to EIA Notification, 2006 and its amendments. The pieces of evidence collected and analysis in the present assessment suggest that, despite a sound legislative, administrative and procedural set-up EIA has notmore » yet evolved satisfactorily in India. An appraisal of the EIA system against systematic evaluation criteria, based on discussions with various stakeholders, EIA expert committee members, approval authorities, project proponents, NGOs and consulting professionals, reveals various drawbacks of the EIA system. These mainly include; inadequate capacity of EIA approval authorities, deficiencies in screening and scoping, poor quality EIA reports, inadequate public participation and weak monitoring. Overall, EIA is used presently as a project justification tool rather than as a project planning tool to contribute to achieving sustainable development. While shortcomings are challenging, Government of India is showing a high degree of commitment. The EIA system in the country is undergoing progressive refinements by steadily removing the constraints. The paper identifies opportunities for taking advantage of the current circumstances for strengthening the EIA process. - Highlights: Black-Right-Pointing-Pointer An assessment has been carried out on Environmental Clearance under EIA Notification, 2006, MoEF, Government of India. Black-Right-Pointing-Pointer EIA system is appraised against systematic evaluation criteria proposed by Ahmad and Wood (2002), Wood (2003), Fuller (1999). Black-Right-Pointing-Pointer The analysis reveals reveals various drawbacks of the EIA system. Black-Right-Pointing-Pointer The paper identifies opportunities to enhance the effectiveness of the EIA system in India.« less

  10. Comparison of DOTA and NODAGA as chelators for (64)Cu-labeled immunoconjugates.

    PubMed

    Ghosh, Sukhen C; Pinkston, Kenneth L; Robinson, Holly; Harvey, Barrett R; Wilganowski, Nathaniel; Gore, Karen; Sevick-Muraca, Eva M; Azhdarinia, Ali

    2015-02-01

    Bifunctional chelators have been shown to impact the biodistribution of monoclonal antibody (mAb)-based imaging agents. Recently, radiolabeled 1,4,7-triazacyclononane,1-glutaric acid-4,7-acetic acid (NODAGA)-peptide complexes have demonstrated improved in vivo stability and performance compared to their 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA) counterparts. Here, we investigated if similar utility could be achieved with mAbs and compared (64)Cu-labeled DOTA and NODAGA-immunoconjugates for the detection of epithelial cell adhesion molecule (EpCAM) in a prostate cancer model. DOTA and NODAGA-immunoconjugates of an EpCAM targeting mAb (mAb7) were synthesized and radiolabeled with (64)Cu (DOTA: 40°C for 1hr; NODAGA: 25°C for 1hr). The average number of chelators per mAb was quantified by isotopic dilution, and the biological activity of the immunoconjugates was evaluated by flow cytometry and ELISA. Radioligand assays were performed to compare cellular uptake and determine the dissociation constant (Kd) and maximum number of binding sites (Bmax) for the immunoconjugates using DsRed-transfected PC3-cells. A PC3-DsRed xenograft tumor model was established in nude mice and used to perform biodistribution studies to compare organ uptake and pharmacokinetics. (64)Cu-DOTA-mAb7 and (64)Cu-NODAGA-mAb7 were prepared with chelator/protein ratios of 2-3 and obtained in comparable radiochemical yields ranging from 59 to 71%. Similar immunoreactivity was observed with both agents, and mock labeling studies indicated that incubation at room temperature or 40°C did not affect potency. (64)Cu-NODAGA-mAb7 demonstrated higher in vitro cellular uptake while (64)Cu-DOTA-mAb7 had higher Kd and Bmax values. From the biodistribution data, we found similar tumor uptake (13.44±1.21%ID/g and 13.24±4.86%ID/g for (64)Cu-DOTA-mAb7 and (64)Cu-NODAGA-mAb7, respectively) for both agents at 24hr, although normal prostate tissue was significantly lower for (64)Cu-NODAGA-mAb7. (64)Cu-NODAGA-mAb7 also had less accumulation in the liver, suggesting excellent retention of the chelation complex in vivo. This was further confirmed by the higher blood activity of (64)Cu-NODAGA-mAb7, which corresponds to increased bioavailability afforded by the enhanced in vivo stability of the agent. Although tumor/muscle ratios were comparable, tumor/prostate ratios were >2-fold and 1.5-fold higher for (64)Cu-NODAGA-mAb7 at 24 and 48hr, respectively, and suggest better ability to discriminate tumor tissue with (64)Cu-NODAGA-mAb7 in our prostate cancer model. To the best of our knowledge, this study represents the first comparison of (64)Cu-labeled DOTA and NODAGA immunoconjugates in vivo. Our results show favorable in vivo performance for (64)Cu-NODAGA-mAb7 which builds upon previous data on our hybrid mAb7 imaging agent by increasing the detection sensitivity for metastatic prostate tumors, as well as for other types of cancer that express EpCAM. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. EIA application in China's expressway infrastructure: clarifying the decision-making hierarchy.

    PubMed

    Zhou, Kai-Yi; Sheate, William R

    2011-06-01

    China's EIA Law came into effect in 2003 and formally requires road transport infrastructure development actions to be subject to Environmental Impact Assessment (EIA). EIAs (including project EIA and plan EIA, or strategic environmental impact assessment, SEA) have been being widely applied in the expressway infrastructure planning field. Among those applications, SEA is applied to provincial level expressway network (PLEI) plans, and project EIA is applied to expressway infrastructure development 'projects' under PLEI plans. Three case studies (one expressway project EIA and two PLEI plan SEAs) were examined to understand currently how EIAs are applied to expressway infrastructure development planning. Through the studies, a number of problems that significantly influence the quality of EIA application in the field were identified. The reasons causing those problems are analyzed and possible solutions are suggested aimed at enhancing EIA practice, helping deliver better decision-making and ultimately improving the environmental performance of expressway infrastructure. Copyright © 2010 Elsevier Ltd. All rights reserved.

  12. Enzyme-antibody dual labeled gold nanoparticles probe for ultrasensitive detection of κ-casein in bovine milk samples.

    PubMed

    Li, Y S; Zhou, Y; Meng, X Y; Zhang, Y Y; Liu, J Q; Zhang, Y; Wang, N N; Hu, P; Lu, S Y; Ren, H L; Liu, Z S

    2014-11-15

    A dual labeled probe was synthesized by coating gold nanoparticles (AuNPs) with anti-κ-CN monoclonal antibody (McAb) and horseradish peroxidase (HRP) enzyme on their surface. The McAb was used as detector and HRP was used as label for signal amplification catalytically oxidize the substrate. AuNPs were used as bridges between the McAb and HRP. Based on the probe, an immunoassay was developed for ultrasensitive detection of κ-CN in bovine milk samples. The assay has a linear response range within 4.2-560 ng mL(-1). The limit of detection (LOD) was 4.2 ng mL(-1) which was 10 times lower than that of traditional McAb-HRP based ELISA. The recoveries of κ-CN from three brand bovine milk samples were from 95.8% to 111.0% that had a good correlation (R(2)=0.998) with those obtained by official standard Kjeldahl method. For higher sensitivity and as simple as the traditional ELISA, the developed immunoassay could provide an alternative approach for ultrasensitive detection of κ-CN in bovine milk sample. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. 21 CFR 801.150 - Medical devices; processing, labeling, or repacking.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... such shipment or delivery, or any part thereof, from such establishment, become void ab initio if the...)(2) of this section shall become void ab initio with respect to the person who introduced such...

  14. 21 CFR 501.100 - Animal food; exemptions from labeling.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... become void ab initio if the food comprising such shipment, delivery, or part is adulterated or... a food under paragraph (d)(2) of this section shall become void ab initio with respect to the person...

  15. 21 CFR 801.150 - Medical devices; processing, labeling, or repacking.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... such shipment or delivery, or any part thereof, from such establishment, become void ab initio if the...)(2) of this section shall become void ab initio with respect to the person who introduced such...

  16. 21 CFR 801.150 - Medical devices; processing, labeling, or repacking.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... such shipment or delivery, or any part thereof, from such establishment, become void ab initio if the...)(2) of this section shall become void ab initio with respect to the person who introduced such...

  17. 21 CFR 801.150 - Medical devices; processing, labeling, or repacking.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... such shipment or delivery, or any part thereof, from such establishment, become void ab initio if the...)(2) of this section shall become void ab initio with respect to the person who introduced such...

  18. 21 CFR 801.150 - Medical devices; processing, labeling, or repacking.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... such shipment or delivery, or any part thereof, from such establishment, become void ab initio if the...)(2) of this section shall become void ab initio with respect to the person who introduced such...

  19. Understanding the long-term influence of EIA on organisational learning and transformation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jones, Megan, E-mail: 31836179@student.murdoch.edu.au; Morrison-Saunders, Angus, E-mail: a.morrison-saunders@murdoch.edu.au

    This research is an attempt to verify the notion postulated by Robert Bartlett and Lynton Caldwell that the full benefits of environmental impact assessment (EIA) would take decades to be realized. While EIA is intended to directly influence decision-making regarding new development proposals, the process is also expected to lead to organisational learning and transformation over time. Our aim was to examine the influence of EIA on a single Western Australian proponent with sustained experience in the process to understand how EIA is used within the organisation and to seek evidence of transformation of the organisation's purpose and mission. Themore » research reviewed literature in order to identify key influences of EIA on organisations, along with semi-structured staff interviews and document analysis for the case study organisation. Ascertaining causality that involvement in EIA processes influences or effects organisational learning and transformation is a challenge in the face of other societal events. Document analysis and interviewee data indicates that the action-forcing nature of EIA did influence proponent behavior through the creation of internal processes seeking to ensure robust design of new projects that would satisfy environmental protection expectations, without the need to trigger formal EIA. Evidence of EIA values and thinking were apparent within internal documentation, including the evolving mission statement. Our research indicates that participation in the EIA process can positively influence organisational learning and transformation by guiding internal change for decision-making. - Highlights: • The long-term influence of EIA on a proponent organisation is investigated. • EIA promotes internal organisational learning and transformation. • Analysis of mission statements can indicate the influence of EIA on organisations. • Organisations aligned with EIA values can reduce the need to engage in formal EIA.« less

  20. 78 FR 78305 - Energy and Water Use Labeling for Consumer Products Under the Energy Policy and Conservation Act...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-26

    ... FEDERAL TRADE COMMISSION 16 CFR Part 305 [3084-AB15] Energy and Water Use Labeling for Consumer Products Under the Energy Policy and Conservation Act (``Energy Labeling Rule'') AGENCY: Federal Trade... to the Energy Labeling Rule (``Rule'') to require a new Department of Energy (DOE) test procedure for...

  1. A review of EIAs on trade policy in China: Exploring the way for economic policy EIAs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mao, Xianqiang, E-mail: maoxq@bnu.edu.cn; Song, Peng, E-mail: songpeng_ee@163.com; Kørnøv, Lone, E-mail: lonek@plan.aau.dk

    During the discussion on the “Environmental Protection Law Amendment (draft)” in 2011, it was decided to drop the proposed clauses related to environmental impact assessments (EIAs) on policy, which means that there remained no provisions for policy EIAs, and China's strategic environmental assessment system stayed limited to the planning level. However, considering that economic policy making is causing significant direct and indirect environmental problems and that almost every aspect of governmental policy has an economic aspect, EIAs on economic policies are of the utmost urgency. The purpose of this study is to review the EIA work that has been carriedmore » out on trade policy in China through four case studies, and illustrate how trade policy EIAs can be helpful in achieving better environmental outcomes in the area of trade. Through the trade policy EIA case studies we try to argue for the feasibility of conducting EIAs on economic policies in China. We also discuss the implications of the case studies from the point of view of how to proceed with EIAs on economic policy and how to promote their practice. - Highlights: • SEA system is incomplete and stays limited to the plan EIA level in China. • EIA on economic policy is of utmost importance for all the developing countries. • Four case studies of trade policy EIA in China are reviewed for policy implications. • Departmental competition for political power impedes economic policy EIAs in China. • Legislative regulation on policy EIA is the first thing needed to overcome barrier.« less

  2. 78 FR 54566 - Energy Labeling Rule

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-05

    ... FEDERAL TRADE COMMISSION 16 CFR Part 305 RIN 3084-AB03 Energy Labeling Rule AGENCY: Federal Trade Commission. ACTION: Final rule; correction. SUMMARY: The Federal Trade Commission published a final rule on July 23, 2013 revising its Energy Labeling Rule. This document makes a technical correction to the...

  3. 64Cu antibody-targeting of the T-cell receptor and subsequent internalization enables in vivo tracking of lymphocytes by PET

    PubMed Central

    Griessinger, Christoph M.; Maurer, Andreas; Kesenheimer, Christian; Kehlbach, Rainer; Reischl, Gerald; Ehrlichmann, Walter; Bukala, Daniel; Harant, Maren; Cay, Funda; Brück, Jürgen; Nordin, Renate; Kohlhofer, Ursula; Rammensee, Hans-Georg; Quintanilla-Martinez, Leticia; Schaller, Martin; Röcken, Martin; Pichler, Bernd J.; Kneilling, Manfred

    2015-01-01

    T cells are key players in inflammation, autoimmune diseases, and immunotherapy. Thus, holistic and noninvasive in vivo characterizations of the temporal distribution and homing dynamics of lymphocytes in mammals are of special interest. Herein, we show that PET-based T-cell labeling facilitates quantitative, highly sensitive, and holistic monitoring of T-cell homing patterns in vivo. We developed a new T-cell receptor (TCR)-specific labeling approach for the intracellular labeling of mouse T cells. We found that continuous TCR plasma membrane turnover and the endocytosis of the specific 64Cu-monoclonal antibody (mAb)–TCR complex enables a stable labeling of T cells. The TCR–mAb complex was internalized within 24 h, whereas antigen recognition was not impaired. Harmful effects of the label on the viability, DNA-damage and apoptosis-necrosis induction, could be minimized while yielding a high contrast in in vivo PET images. We were able to follow and quantify the specific homing of systemically applied 64Cu-labeled chicken ovalbumin (cOVA)-TCR transgenic T cells into the pulmonary and perithymic lymph nodes (LNs) of mice with cOVA-induced airway delayed-type hypersensitivity reaction (DTHR) but not into pulmonary and perithymic LNs of naïve control mice or mice diseased from turkey or pheasant OVA-induced DTHR. Our protocol provides consequent advancements in the detection of small accumulations of immune cells in single LNs and specific homing to the sites of inflammation by PET using the internalization of TCR-specific mAbs as a specific label of T cells. Thus, our labeling approach is applicable to other cells with constant membrane receptor turnover. PMID:25587131

  4. Theorising EIA effectiveness: A contribution based on the Danish system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lyhne, Ivar, E-mail: lyhne@plan.aau.dk; Laerhoven, Frank van; Cashmore, Matthew

    Considerable attention has been given to the effectiveness of environmental impact assessment (EIA) since the 1970s. Relatively few research studies, however, have approached EIA as an instrument of environmental governance, and have explored the mechanisms through which EIA influences the behaviour of actors involved in planning processes. Consequently, theory in this area is underspecified. In this paper we contribute to theory-building by analysing the effectiveness of a unique EIA system: the Danish system. In this system the competent authority, instead of the project proponent, undertakes EIA reporting. Additionally, the public, rather than experts, play a central role in quality controlmore » and the Danish EIA community is relatively small which influences community dynamics in particular ways. A nation-wide survey and expert interviews were undertaken in order to examine the views of actors involved in EIA on the effectiveness of this anomalous system. The empirical data are compared with similar studies on governance mechanisms in other countries, especially the United Kingdom and the Netherlands, as well as with earlier evaluations of EIA effectiveness in Denmark. The results indicate that the more extensive role attributed to the competent authority may lead to higher EIA effectiveness when this aligns with their interests; the influence of the public is amplified by a powerful complaints system; and, the size of the EIA community appears to have no substantial influence on EIA effectiveness. We discuss how the research findings might enhance our theoretical understanding of the operation and effectiveness of governance mechanisms in EIA. - Highlights: • The effectiveness of the unique Danish EIA system is explored. • Results are compared with similar studies in the Netherlands and the UK. • Findings lead to hypotheses that contribute to theorising EIA effectiveness.« less

  5. Durable donor engraftment after radioimmunotherapy using α-emitter astatine-211–labeled anti-CD45 antibody for conditioning in allogeneic hematopoietic cell transplantation

    PubMed Central

    Chen, Yun; Kornblit, Brian; Hamlin, Donald K.; Sale, George E.; Santos, Erlinda B.; Wilbur, D. Scott; Storer, Barry E.; Storb, Rainer

    2012-01-01

    To reduce toxicity associated with external γ-beam radiation, we investigated radioimmunotherapy with an anti-CD45 mAb labeled with the α-emitter, astatine-211 (211At), as a conditioning regimen in dog leukocyte antigen-identical hematopoietic cell transplantation (HCT). Dose-finding studies in 6 dogs treated with 100 to 618 μCi/kg 211At-labeled anti-CD45 mAb (0.5 mg/kg) without HCT rescue demonstrated dose-dependent myelosuppression with subsequent autologous recovery, and transient liver toxicity in dogs treated with 211At doses less than or equal to 405 μCi/kg. Higher doses of 211At induced clinical liver failure. Subsequently, 8 dogs were conditioned with 155 to 625 μCi/kg 211At-labeled anti-CD45 mAb (0.5 mg/kg) before HCT with dog leukocyte antigen-identical bone marrow followed by a short course of cyclosporine and mycophenolate mofetil immunosuppression. Neutropenia (1-146 cells/μL), lymphopenia (0-270 cells/μL), and thrombocytopenia (1500-6560 platelets/μL) with prompt recovery was observed. Seven dogs had long-term donor mononuclear cell chimerism (19%-58%), whereas 1 dog treated with the lowest 211At dose (155 μCi/kg) had low donor mononuclear cell chimerism (5%). At the end of follow-up (18-53 weeks), only transient liver toxicity and no renal toxicity had been observed. In conclusion, conditioning with 211At-labeled anti-CD45 mAb is safe and efficacious and provides a platform for future clinical trials of nonmyeloablative transplantation with radioimmunotherapy-based conditioning. PMID:22134165

  6. Target-regulated proximity hybridization with three-way DNA junction for in situ enhanced electronic detection of marine biotoxin based on isothermal cycling signal amplification strategy.

    PubMed

    Liu, Bingqian; Chen, Jinfeng; Wei, Qiaohua; Zhang, Bing; Zhang, Lan; Tang, Dianping

    2015-07-15

    A new signal amplification strategy based on target-regulated DNA proximity hybridization (TRPH) reaction accompanying formation of three-way DNA junction was designed for electronic detection of Microcystin-LR (MC-LR used in this case), coupling with junction-induced isothermal cycling signal amplification. Initially, a sandwiched-type immunoreaction was carried out in a low-cost PCR tube between anti-MC-LR mAb1 antibody-labeled DNA1 (mAb1-DNA1) and anti-MC-LR mAb2-labeled DNA2 (mAb2-DNA2) in the presence of target to form a three-way DNA junction. Then, the junction could undergo an unbiased strand displacement reaction on an h-like DNA nanostructure-modified electrode (labeled with methylene blue redox tag on the short DNA strand), thereby resulting in the dissociation of methylene blue-labeled signal DNA from the electrode. The newly formed double-stranded DNA could be cleaved again by exonuclease III, and the released three-way DNA junction retriggered the strand-displacement reaction with h-like DNA nanostructures for junction recycling. During the strand-displacement reaction, numerous methylene blue-labeled DNA strands were far away from the electrode, thus decreasing the detectable electrochemical signal within the applied potentials. Under optimal conditions, the TRPH-based immunosensing system exhibited good electrochemical responses for detecting target MC-LR at a concentration as low as 1.0ngkg(-1) (1.0ppt). Additionally, the precision, reproducibility, specificity and method accuracy were also investigated with acceptable results. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Environmental impact assessment in urban transport planning: Exploring process-related barriers in Spanish practice

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Soria-Lara, Julio A., E-mail: j.a.sorialara@uva.nl; Bertolini, Luca, E-mail: l.bertolini@uva.nl; Brömmelstroet, Marco te, E-mail: M.C.G.teBrommelstroet@uva.nl

    The effectiveness of EIA for evaluating transport planning projects is increasingly being questioned by practitioners, institutions and scholars. The academic literature has traditionally focused more on solving content-related problems with EIA (i.e. the measurement of environmental effects) than on process-related issues (i.e. the role of EIA in the planning process and the interaction between key actors). Focusing only on technical improvements is not sufficient for rectifying the effectiveness problems of EIA. In order to address this knowledge gap, the paper explores how EIA is experienced in the Spanish planning context and offers in-depth insight into EIA process-related issues in themore » field of urban transport planning. From the multitude of involved actors, the research focuses on exploring the perceptions of the two main professional groups: EIA developers and transport planners. Through a web-based survey we assess the importance of process-related barriers to the effective use of EIA in urban transport planning. The analyses revealed process issues based fundamentally on unstructured stakeholders involvement and an inefficient public participation - Highlights: • Qualitative research on perceptions of EIA participants on EIA processes. • Web-based survey with different participants (EIA-developers; transport planners). • It was seen an inefficient participation of stakeholders during the EIA processes.« less

  8. Nanobeads-based assays. The case of gluten detection

    NASA Astrophysics Data System (ADS)

    Venditti, Iole; Fratoddi, Ilaria; Vittoria Russo, Maria; Bellucci, Stefano; Crescenzo, Roberta; Iozzino, Luisa; Staiano, Maria; Aurilia, Vincenzo; Varriale, Antonio; Rossi, Mosè; D'Auria, Sabato

    2008-11-01

    In order to verify if the use of nanobeads of poly[phenylacetylene-(co-acrylic acid)] (PPA/AA) in the ELISA test would affect the immune-activity of the antibodies (Ab) and/or the activity of the enzymes used to label the Ab anti-rabbit IGg, in this work we immobilized the horse liver peroxidase labelled Ab anti-rabbit IGg onto PPA/AA nanobeads. The gluten test was chosen as the model to demonstrate the usefulness of these nanobeads in immunoassays. The synthesis of PPA/AA nanobeads was performed by a modified emulsion polymerization. Self-assembly of nanospheres with mean diameter equal to 200 nm was achieved by casting aqueous suspensions. The materials were characterized by traditional spectroscopic techniques, while the size and dispersion of the particles were analysed by scanning electron microscopy (SEM) measurements. The obtained results show that the immobilization process of the Abs onto PPA/AA did not affect either the immune-response of the Abs or the functional activity of the peroxidase suggesting the usefulness of PPA/AA for the design of advanced nanobeads-based assays for the simultaneous screening of several analytes in complex media.

  9. Blockade of human P2X7 receptor function with a monoclonal antibody.

    PubMed

    Buell, G; Chessell, I P; Michel, A D; Collo, G; Salazzo, M; Herren, S; Gretener, D; Grahames, C; Kaur, R; Kosco-Vilbois, M H; Humphrey, P P

    1998-11-15

    A monoclonal antibody (MoAb) specific for the human P2X7 receptor was generated in mice. As assessed by flow cytometry, the MoAb labeled human blood-derived macrophage cells natively expressing P2X7 receptors and cells transfected with human P2X7 but not other P2X receptor types. The MoAb was used to immunoprecipitate the human P2X7 receptor protein, and in immunohistochemical studies on human lymphoid tissue, P2X7 receptor labeling was observed within discrete areas of the marginal zone of human tonsil sections. The antibody also acted as a selective antagonist of human P2X7 receptors in several functional studies. Thus, whole cell currents, elicited by the brief application of 2',3'-(4-benzoyl)-benzoyl-ATP in cells expressing human P2X7, were reduced in amplitude by the presence of the MoAb. Furthermore, preincubation of human monocytic THP-1 cells with the MoAb antagonized the ability of P2X7 agonists to induce the release of interleukin-1beta.

  10. 75 FR 41838 - Agency Information Collection Activities: Proposed Collection; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-19

    ... Institutional Coal Users;'' EIA-4, ``Weekly Coal Monitoring Report--Coke Plants'' (Standby); EIA-5, ``Quarterly Coal Consumption and Quality Report--Coke Plants;'' EIA-6Q (Schedule Q), ``Quarterly Coal Report... Coal Consumption and Quality Report--Coke Plants) EIA proposes to make changes to the Form EIA-5 survey...

  11. An analysis framework for characterizing and explaining development of EIA legislation in developing countries-Illustrated for Georgia, Ghana and Yemen

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kolhoff, Arend J., E-mail: akolhoff@eia.nl; Driessen, Peter P.J., E-mail: p.driessen@uu.nl; Runhaar, Hens A.C., E-mail: h.a.c.runhaar@uu.nl

    2013-01-15

    Actors in the field of international development co-operation supporting the development of EIA legislation in developing countries often do not achieve the results envisaged. The performance of EIA in these countries often remains weak. One reason, we assume, is that often those actors support the establishment of overly ambitious EIA legislation that cannot achieve its objectives in the light of constraining contexts. To provide more effective support we need to better understand the enabling and constraining contextual factors that influence the development of EIA legislation and to which support actors should align itself. In this article a new analysis frameworkmore » for classifying, characterizing and explaining the development of EIA legislation is described, measured in terms of ambition levels. Ambitions are defined as intentions the EIA authorities aim to fulfill, expressed in formal EIA legislation. Three country cases, Yemen, Georgia and Ghana are used to illustrate the usefulness of our framework and as a first test to refine the framework. We have formulated the following five hypotheses that complement and refine our analysis framework. One, EIA legislation may develop multilinearly in terms of ambition levels. Two, ambitions in EIA legislation seem to be influenced to a great extent by the power and capacity of, on the one hand, the environmental authorities supporting EIA and, on the other hand, the sector authorities hindering the development of EIA. Three, the political system is the most important context factor influencing the rules of policy-making and the power of the different actors involved. Four, the importance of context factors on the development of ambitions is dependent on the phase of EIA system development. Five, some ambitions seem to be influenced by particular factors; for instance the ambitions for the object of study seem to be influenced by the level of environmental awareness of the sector ministries and parliament. The analysis framework may also assist actors involved in the development of EIA legislation in setting ambitions for EIA legislation that are feasible within the context in which it will be developed and implemented. Application of a country-specific EIA model would seem to be the preferred model to develop EIA legislation because by taking capacities of actors and context factors as a starting point, it offers more potential to well-performing EIA systems. - Highlights: Black-Right-Pointing-Pointer EIA systems develop from less to high ambitious and sometimes vice versa. Black-Right-Pointing-Pointer Ambitions in EIA legislation are determined by the capacity of environment- and sector authority. Black-Right-Pointing-Pointer The political system is the most important context factor explaining the ambitions of an EIA system. Black-Right-Pointing-Pointer An analysis framework developed to measure EIA system ambitions might help to setambitions.« less

  12. Molecular identification and first report of mitochondrial COI gene haplotypes in the hawksbill turtle Eretmochelys imbricata (Testudines: Cheloniidae) in the Colombian Caribbean nesting colonies.

    PubMed

    Daza-Criado, L; Hernández-Fernández, J

    2014-02-21

    Hawksbill sea turtles Eretmochelys imbricata are found extensively around the world, including the Atlantic, Pacific, and Indian Oceans; the Persian Gulf, and the Red and Mediterranean Seas. Populations of this species are affected by international trafficking of their shields, meat, and eggs, making it a critically endangered animal. We determined the haplotypes of 17 hawksbill foraging turtles of Islas del Rosario (Bolivar) and of the nesting beach Don Diego (Magdalena) in the Colombian Caribbean based on amplification and sequencing of the mitochondrial gene cytochrome oxidase c subunit I (COI). We identified 5 haplotypes, including EI-A1 previously reported in Puerto Rico, which was similar to 10 of the study samples. To our knowledge, the remaining 4 haplotypes have not been described. Samples EICOI11 and EICOI3 showed 0.2% divergence from EI-A1, by a single nucleotide change, and were classified as the EI-A2 haplotype. EICOI6, EICOI14, and EICOI12 samples showed 0.2% divergence from EI-A1 and 0.3% divergence from EI-A2 and were classified as EI-A3 haplotype. Samples EICOI16 and EICOI15 presented 5 nucleotide changes each and were classified as 2 different haplotypes, EI-A4 and EI-A5, respectively. The last 2 haplotypes had higher nucleotide diversity (K2P=1.7%) than that by the first 3 haplotypes. EI-A1 and EI-A2 occurred in nesting individuals, and EI-A2, EI-A3, EI-A4, and EI-A5 occurred in foraging individuals. The description of the haplotypes may be associated with reproductive migrations or foraging and could support the hypothesis of natal homing. Furthermore, they can be used in phylogeographic studies.

  13. Microfluidic immunosensor for rapid and highly-sensitive salivary cortisol quantification.

    PubMed

    Pinto, V; Sousa, P; Catarino, S O; Correia-Neves, M; Minas, G

    2017-04-15

    This paper presents a novel poly(dimethylsiloxane) (PDMS) microfluidic immunosensor that integrates a complementary metal-oxide-semiconductor (CMOS) optical detection system for a rapid and highly-sensitive quantification of salivary cortisol. The simple and non-invasive method of saliva sampling provides an interesting alternative to the blood, allowing a fast sampling at short intervals, relevant for many clinical diagnostic applications. The developed approach is based on the covalent immobilization of a coating antibody (Ab), a polyclonal anti-IgG, onto a treated PDMS surface. The coating Ab binds the capture Ab, an IgG specific for cortisol, allowing its correct orientation. Horseradish peroxidase (HRP)-labelled cortisol is added to compete with the cortisol in the sample, for the capture Ab binding sites. The HRP-labelled cortisol, bonded to the capture Ab, is measured through the HRP enzyme and the tetramethylbenzidine (TMB) substrate reaction. The cortisol quantification is performed by colorimetric detection of HRP-labelled cortisol, through optical absorption at 450nm, using a CMOS silicon photodiode as the photodetector. Under the developed optimized conditions presented here, e.g., microfluidic channels geometry, immobilization method and immunoassay conditions, the immunosensor shows a linear range of detection between 0.01-20ng/mL, a limit of detection (LOD) of 18pg/mL and an analysis time of 35min, featuring a great potential for point-of-care applications requiring continuous monitoring of the salivary cortisol levels during a circadian cycle. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. PET Imaging of VEGFR-2 Expression in Lung Cancer with 64Cu-Labeled Ramucirumab.

    PubMed

    Luo, Haiming; England, Christopher G; Graves, Stephen A; Sun, Haiyan; Liu, Glenn; Nickles, Robert J; Cai, Weibo

    2016-02-01

    Lung cancer accounts for 17% of cancer-related deaths worldwide, and most patients present with locally advanced or metastatic disease. Novel PET imaging agents for assessing vascular endothelial growth factor receptor-2 (VEGFR-2) expression can be used for detecting VEGFR-2-positive malignancies and subsequent monitoring of therapeutic response to VEGFR-2-targeted therapies. Here, we report the synthesis and characterization of an antibody-based imaging agent for PET imaging of VEGFR-2 expression in vivo. Ramucirumab (named RamAb), a fully humanized IgG1 monoclonal antibody, was conjugated to 2-S-(4-isothiocyanatobenzyl)-1,4,7-triazacyclononane-1,4,7-triacetic acid (p-SCN-Bn-NOTA) and labeled with (64)Cu. Flow cytometry analysis and microscopy studies were performed to compare the VEGFR-2 binding affinity of RamAb and NOTA-RamAb. PET imaging and biodistribution studies were performed in nude mice bearing HCC4006 and A549 xenograft tumors. Ex vivo histopathology was performed to elucidate the expression patterns of VEGFR-2 in different tissues and organs to validate in vivo results. Flow cytometry examination revealed the specific binding capacity of fluorescein isothiocyanate-RamAb to VEGFR-2, and no difference in VEGFR-2 binding affinity was seen between RamAb and NOTA-RamAb. After being labeled with (64)Cu, PET imaging revealed specific and prominent uptake of (64)Cu-NOTA-RamAb in VEGFR-2-positive HCC4006 tumors (9.4 ± 0.5 percentage injected dose per gram at 48 h after injection; n = 4) and significantly lower uptake in VEGFR-2-negative A549 tumors (4.3 ± 0.2 percentage injected dose per gram at 48 h after injection; n = 3). Blocking experiments revealed significantly lower uptake in HCC4006 tumors, along with histology analysis, further confirming the VEGFR-2 specificity of (64)Cu-NOTA-RamAb. This study provides initial evidence that (64)Cu-NOTA-RamAb can function as a PET imaging agent for visualizing VEGFR-2 expression in vivo, which may also find potential applications in monitoring the treatment response of VEGFR-2-targeted cancer therapy. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Clausen, Alison, E-mail: aliclausen@protocol.com.a; Vu, Hoang Hoa, E-mail: hoanghoavu@yahoo.co; Pedrono, Miguel, E-mail: pedrono@cirad.f

    Vietnam has one of the fastest growing economies in the world and has achieved significant socio-economic development in recent years. However this growth is placing increased pressure on an already depleted natural environment. Environmental impact assessment (EIA) is recognised by the Government and international organizations as an important tool in the management of the impacts of future development on the country's natural resource base. The Government's commitment to EIA has been demonstrated through the development and adoption of the Law on Environment Protection (Revised) in 2005 which sets out the requirements for EIA and which represents a major step inmore » the development of a robust legislative framework for EIA in Vietnam. The Law on Environment Protection (Revised) 2005 has now been operational for several years and we have undertaken an evaluation of the resulting EIA system in Vietnam. We argue that while significant improvements have been achieved in the EIA policy framework, an important gap remains between EIA theory and practice. We contend that the basis of the current EIA legislation is strong and that future developments of the EIA system in Vietnam should focus on improving capacity of EIA practitioners rather than further substantial legislative change. Such improvements would allow the Vietnamese EIA system to emerge as an effective and efficient tool for environmental management in Vietnam and as a model EIA framework for other developing countries.« less

  16. Development and validation of an LC-MS/MS method for quantification of cyclic guanosine 3',5'-monophosphate (cGMP) in clinical applications: a comparison with a EIA method.

    PubMed

    Zhang, Yanhua; Dufield, Dawn; Klover, Jon; Li, Wenlin; Szekely-Klepser, Gabriella; Lepsy, Christopher; Sadagopan, Nalini

    2009-02-15

    An LC-MS/MS method was developed and validated to quantify endogenous cyclic guanosine 3',5'-monophosphate (cGMP) in human plasma. The LC-MS/MS and competitive enzyme immunoassay (EIA) assays were compared. cGMP concentrations of 20 human plasma samples were measured by both methods. For the MS-based assay, plasma samples were subjected to a simple protein precipitation procedure by acetonitrile prior to analysis by electrospray ionization LC-MS/MS. De-protonated analytes generated in negative ionization mode were monitored through multiple reaction monitoring (MRM). A stable isotope-labeled internal standard, (13)C(10),(15)N(5)-cGMP, which was biosynthesized in-house, was used in the LC-MS/MS method. The competitive EIA was validated using a commercially available cGMP fluorescence assay kit. The intra-assay accuracy and precision for MS-based assay for cGMP were 6-10.1% CV and -3.6% to 7.3% relative error (RE), respectively, while inter-assay precision and accuracy were 5.6-8.1% CV and -2.1% to 6.3% RE, respectively. The intra-assay accuracy and precision for EIA were 17.9-27.1% CV and -4.9% to 24.5% RE, respectively, while inter-assay precision and accuracy were 15.1-39.5% CV and -30.8% to 4.37% RE, respectively. Near the lower limits of detection, there was little correlation between the cGMP concentration values in human plasma generated by these two methods (R(2)=0.197, P=0.05). Overall, the MS-based assay offered better selectivity, recovery, precision and accuracy over a linear range of 0.5-20ng/mL. The LC-MS/MS method provides an effective tool for the quantitation of cGMP to support clinical mechanistic studies of curative pharmaceuticals.

  17. Five Years Later: A Look at the EIA Investment.

    ERIC Educational Resources Information Center

    South Carolina State Dept. of Education, Columbia. Div. of Public Accountability.

    A 5-year review of the impact of South Carolina's comprehensive reform legislation, the Education Improvement Act of 1984 (EIA), is presented. Throughout the report, comparisons of EIA program productivity in 1989 with pre-EIA performance are displayed in short program summaries, 33 graphs, and 14 tables. The EIA targeted seven major areas for…

  18. 75 FR 56527 - Agency Information Collection Activities: Submission for OMB Review; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-16

    ... manufactured, shipped, and/or imported solar thermal collectors and/or photovoltaic modules and cells. The EIA... request. SUMMARY: The EIA has submitted the forms EIA-63A, ``Annual Solar Thermal Collector Manufacturers Survey,'' EIA-63B, ``Annual Photovoltaic Module/Cell Manufacturers Survey,'' and the EIA-902, ``Annual...

  19. Laboratory and Clinical features of EIA Toxin-positive and EIA Toxin-negative Community-acquired Clostridium difficile Infection.

    PubMed

    Patel, Hiren; Randhawa, Jeewanjot; Nanavati, Sushant; Marton, L Randy; Baddoura, Walid J; DeBari, Vincent A

    2015-01-01

    Studies have described the clinical course of patients with Clostridium difficile infection (CDI) with positive enzyme immunoassay (EIA) for toxins A and B. Limited information is available for the patients with negative EIA but positive for the toxin B gene (TcdB) by the PCR. The aim of our study is to determine if there are any differences that exist among the clinical and laboratory parameters in the patients tested to be positive by EIA for toxin and those who were negative. This is a retrospective cohort study conducted in a 700-bed teaching hospital. We reviewed charts of the patients with presumptive CDI between January 2006 and July 2013. We divided these patients into two groups, EIA-positive and EIA-negative, based on result of EIA for toxins A and B and the requirement for a positive PCR analysis of the TcdB gene. The EIA-positive group had significantly higher white blood cell counts (p<0.001), with a significantly greater percentage of bands (p<0.0001). Albumin and total protein both exhibit significantly (p<0.0001, both comparisons) lower values in the EIA-positive group. Among clinical findings, the EIA-positive group had significantly longer length of hospital stay (p=0.010). These data suggest that an infection with an EIA-negative strain of C. difficile presents laboratory markers closer to those of healthy subjects and clinical features suggesting considerably less severe than infection with EIA-positive C. difficile. © 2015 by the Association of Clinical Scientists, Inc.

  20. An ultrasensitive label-free electrochemiluminescent immunosensor for measuring Cry1Ab level and genetically modified crops content.

    PubMed

    Gao, Hongfei; Wen, Luke; Wu, Yuhua; Fu, Zhifeng; Wu, Gang

    2017-11-15

    The development of genetically modified (GM) insect-resistant crops has aroused great public concern about the risks on the eco-environment resulting from a release of toxic Cry proteins (such as Cry1Ab) to the soil. Therefore, it is of crucial importance to measure the Cry proteins level and the GM crops content. Here, we have tested for the first time a method that uses novel carbon nanospheres (CNPs) label-free electrochemiluminescent (ECL) immunosensor for the ultrasensitive quantification of Cry1Ab and GM crops. In this work, novel CNPs were prepared from printer toner with a very facile approach, and linked with anti-Cry1Ab antibodies to modify a golden working electrode. The immunoreaction between Cry1Ab and its antibody formed an immunocomplex on the bioreceptor region of the sensor, which inhibited electron transfer between the electrode surface and the ECL substance, leading to a decrease of ECL response. Under the optimal conditions, the fabricated label-free ECL immunosensor determined Cry1Ab down to 3.0pgmL -1 within a linear range of 0.010-1.0ngmL -1 , showing significant improvement of sensitivity than that of most previous reports. Meanwhile, the proposed method was successfully applied for GM rice BT63 and GM maize MON810 detections down to 0.010% and 0.020%, respectively. Due to its outstanding advantages such as high sensitivity, ideal selectivity, simple fabrication, rapid detection, and low cost, the developed method can be considered as a powerful and pioneering tool for GM crops detection. Its use can also be extended to other toxin protein sensing in foods. Copyright © 2017. Published by Elsevier B.V.

  1. 27 CFR 5.32 - Mandatory label information.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Distilled Spirits § 5.32 Mandatory label information. There shall be stated: (a) On the brand label: (1) Brand name. (2) Class and type, in accordance with § 5.35. (3) Alcoholic content, in accordance with § 5... prescribed in § 5.47, net contents in accordance with § 5.38(b) or § 5.38a(b)(2). (b) On the brand label or...

  2. Integrating human health into environmental impact assessment: an unrealized opportunity for environmental health and justice.

    PubMed

    Bhatia, Rajiv; Wernham, Aaron

    2008-08-01

    The National Environmental Policy Act and related state laws require many public agencies to analyze and disclose potentially significant environmental effects of agency actions, including effects on human health. In this paper we review the purpose and procedures of environmental impact assessment (EIA), existing regulatory requirements for health effects analysis, and potential barriers to and opportunities for improving integration of human health concerns within the EIA process. We use statutes, regulations, guidelines, court opinions, and empirical research on EIA along with recent case examples of integrated health impact assessment (HIA)/EIA at both the state and federal level. We extract lessons and recommendations for integrated HIA/EIA practice from both existing practices as well as case studies. The case studies demonstrate the adequacy, scope, and power of existing statutory requirements for health analysis within EIA. The following support the success of integrated HIA/EIA: a proponent recognizing EIA as an available regulatory strategy for public health; the openness of the agency conducting the EIA; involvement of public health institutions; and complementary objectives among community stakeholders and health practitioners. We recommend greater collaboration among institutions responsible for EIA, public health institutions, and affected stakeholders along with guidance, resources, and training for integrated HIA/EIA practice.

  3. Integrating Human Health into Environmental Impact Assessment: An Unrealized Opportunity for Environmental Health and Justice

    PubMed Central

    Bhatia, Rajiv; Wernham, Aaron

    2008-01-01

    Objectives The National Environmental Policy Act and related state laws require many public agencies to analyze and disclose potentially significant environmental effects of agency actions, including effects on human health. In this paper we review the purpose and procedures of environmental impact assessment (EIA), existing regulatory requirements for health effects analysis, and potential barriers to and opportunities for improving integration of human health concerns within the EIA process. Data sources We use statutes, regulations, guidelines, court opinions, and empirical research on EIA along with recent case examples of integrated health impact assessment (HIA)/EIA at both the state and federal level. Data synthesis We extract lessons and recommendations for integrated HIA/EIA practice from both existing practices as well as case studies. Conclusions The case studies demonstrate the adequacy, scope, and power of existing statutory requirements for health analysis within EIA. The following support the success of integrated HIA/EIA: a proponent recognizing EIA as an available regulatory strategy for public health; the openness of the agency conducting the EIA; involvement of public health institutions; and complementary objectives among community stakeholders and health practitioners. We recommend greater collaboration among institutions responsible for EIA, public health institutions, and affected stakeholders along with guidance, resources, and training for integrated HIA/EIA practice. PMID:18709140

  4. Evaluation of desialylation during 2-amino benzamide labeling of asparagine-linked oligosaccharides.

    PubMed

    Aich, Udayananth; Hurum, Deanna C; Basumallick, Lipika; Rao, Srinivasa; Pohl, Chris; Rohrer, Jeffrey S; Kandzia, Sebastian

    2014-08-01

    Labeling of released asparagine-linked (N-linked) oligosaccharides from glycoproteins is commonly performed to aid in the separation and detection of the oligosaccharide. Of the many available oligosaccharide labels, 2-amino benzamide (2-AB) is a popular choice for providing a fluorescent product. The derivatization conditions can potentially lead to oligosaccharide desialylation. This work evaluated the extent of sialic acid loss during 2-AB labeling of N-linked oligosaccharides released from bovine fetuin, polyclonal human serum immunoglobulin G (IgG), and human α1-acid glycoprotein (AGP) as well as of sialylated oligosaccharide reference standards and found that for more highly sialylated oligosaccharides the loss is greater than the <2% value commonly cited. Manufacturers of glycoprotein biotherapeutics need to produce products with a consistent state of sialylation and, therefore, require an accurate assessment of glycoprotein sialylation. Copyright © 2014 Elsevier Inc. All rights reserved.

  5. Monoclonal Antibodies Radiolabeling with Rhenium-188 for Radioimmunotherapy

    PubMed Central

    Martini, Petra; Pasquali, Micol

    2017-01-01

    Rhenium-188, obtained from an alumina-based tungsten-188/rhenium-188 generator, is actually considered a useful candidate for labeling biomolecules such as antibodies, antibody fragments, peptides, and DNAs for radiotherapy. There is a widespread interest in the availability of labeling procedures that allow obtaining 188Re-labeled radiopharmaceuticals for various therapeutic applications, in particular for the rhenium attachment to tumor-specific monoclonal antibodies (Mo)Abs for immunotherapy. Different approaches have been developed in order to obtain 188Re-radioimmunoconjugates in high radiochemical purity starting from the generator eluted [188Re]ReO4−. The aim of this paper is to provide a short overview on 188Re-labeled (Mo)Abs, focusing in particular on the radiolabeling methods, quality control of radioimmunoconjugates, and their in vitro stability for radioimmunotherapy (RIT), with particular reference to the most important contributions published in literature in this topic. PMID:28951872

  6. Monoclonal Antibodies Radiolabeling with Rhenium-188 for Radioimmunotherapy.

    PubMed

    Uccelli, Licia; Martini, Petra; Pasquali, Micol; Boschi, Alessandra

    2017-01-01

    Rhenium-188, obtained from an alumina-based tungsten-188/rhenium-188 generator, is actually considered a useful candidate for labeling biomolecules such as antibodies, antibody fragments, peptides, and DNAs for radiotherapy. There is a widespread interest in the availability of labeling procedures that allow obtaining 188 Re-labeled radiopharmaceuticals for various therapeutic applications, in particular for the rhenium attachment to tumor-specific monoclonal antibodies (Mo)Abs for immunotherapy. Different approaches have been developed in order to obtain 188 Re-radioimmunoconjugates in high radiochemical purity starting from the generator eluted [ 188 Re]ReO 4 - . The aim of this paper is to provide a short overview on 188 Re-labeled (Mo)Abs, focusing in particular on the radiolabeling methods, quality control of radioimmunoconjugates, and their in vitro stability for radioimmunotherapy (RIT), with particular reference to the most important contributions published in literature in this topic.

  7. Serological Evaluation of Immunity to the Varicella-Zoster Virus Based on a Novel Competitive Enzyme-Linked Immunosorbent Assay

    PubMed Central

    Liu, Jian; Ye, Xiangzhong; Jia, Jizong; Zhu, Rui; Wang, Lina; Chen, Chunye; Yang, Lianwei; Wang, Yongmei; Wang, Wei; Ye, Jianghui; Li, Yimin; Zhu, Hua; Zhao, Qinjian; Cheng, Tong; Xia, Ningshao

    2016-01-01

    Varicella-zoster virus (VZV) is a highly contagious agent of varicella and herpes zoster. Varicella can be lethal to immunocompromised patients, babies, HIV patients and other adults with impaired immunity. Serological evaluation of immunity to VZV will help determine which individuals are susceptible and evaluate vaccine effectiveness. A collection of 110 monoclonal antibodies (mAbs) were obtained by immunization of mice with membrane proteins or cell-free virus. The mAbs were well characterized, and a competitive sandwich ELISA (capture mAb: 8H6; labelling mAb: 1B11) was established to determine neutralizing antibodies in human serum with reference to the FAMA test. A total of 920 human sera were evaluated. The competitive sandwich ELISA showed a sensitivity of 95.6%, specificity of 99.77% and coincidence of 97.61% compared with the fluorescent-antibody-to-membrane-antigen (FAMA) test. The capture mAb 8H6 was characterized as a specific mAb for VZV ORF9, a membrane-associated tegument protein that interacts with glycoprotein E (gE), glycoprotein B (gB) and glycoprotein C (gC). The labelling mAb 1B11 was characterized as a complement-dependent neutralizing mAb specific for the immune-dominant epitope located on gE, not on other VZV glycoproteins. The established competitive sandwich ELISA could be used as a rapid and high-throughput method for evaluating immunity to VZV. PMID:26853741

  8. The influence of actor capacities on EIA system performance in low and middle income countries —Cases from Georgia and Ghana

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kolhoff, Arend J., E-mail: akolhoff@eia.nl; Runhaar, Hens A.C., E-mail: H.A.C.Runhaar@uu.nl; Forest and Nature Conservation Policy Group, Wageningen University and Research Centre, Wageningen

    In this paper, we aim to better understand the factors that contribute to the substantive performance of EIA systems in low and middle income countries. Substantive performance is defined as the extent to which the EIA process contributes to the EIA objectives for the long term, namely environmental protection or, even more ambitious, sustainable development. We have therefore developed a conceptual model in which we focus on the key actors in the EIA system, the proponent and the EIA authority and their level of ownership as a key capacity to measure their performance, and we distinguish procedural performance and somemore » contextual factors. This conceptual model is then verified and refined for the EIA phase and the EIA follow-up phase (permitting, monitoring and enforcement) by means of 12 case studies from Ghana (four cases) and Georgia (eight cases), both lower–middle income countries. We observe that in most cases the level of substantive performance increases during the EIA phase but drops during the EIA follow-up phase, and as a result only five out of 12 operational cases are in compliance with permit conditions or national environmental standards. We conclude, firstly that ownership of the proponent is the most important factor explaining the level of substantive performance; the higher the proponent's level of ownership the higher the level of substantive performance. The influence of the EIA authority on substantive performance is limited. Secondly, the influence of procedural performance on substantive performance seems less important than expected in the EIA phase but more important during the EIA follow-up phase. In order to improve substantive performance we learned two lessons. Firstly, increasing the proponent's level of ownership seems obvious, but direct change is probably difficult. However, where international finance institutes are involved they can increase ownership. Despite the limited influence of the EIA authority, a proactive strategy of, for example, working together with international finance institutes has a slightly larger influence than a reactive strategy. - Highlights: • Ownership of the proponent is the most important factor explaining the level of substantive performance. • The influence of the EIA authority on substantive performance is limited. • The influence of procedural performance on substantive performance seems less important than expected in the EIA phase but more important during the EIA follow-up phase.« less

  9. Immunoscintigraphy of ovarian cancer with indium-111-labeled OV-TL 3 F(ab')2 monoclonal antibody.

    PubMed

    Massuger, L F; Kenemans, P; Claessens, R A; Verheijen, R H; Schijf, C P; Strijk, S P; Poels, L G; van Hoesel, R G; Corstens, F H

    1990-11-01

    The safety and diagnostic accuracy of immunoscintigraphy with the indium-111-labeled monoclonal antibody OV-TL 3 F(ab')2(111In-OV-TL 3 F(ab')2) for diagnosis and follow-up of ovarian cancer was prospectively studied in 31 patients. Planar and SPECT scintigraphy were performed up to 4 days after i.v. injection of 140 MBq 111In-OV-TL 3 F(ab')2. Surgical evaluation was possible in 22 out of 31 patients. Imaging results were compared with X-ray computed tomography, ultrasound, and CA 125 serum level using the histologically confirmed surgical findings as a "gold standard." Apart from a transient rash observed in two patients, no other immediate or delayed adverse reactions were observed. Within the surgically evaluated group, ovarian cancer lesions were detected in 16 out of 17 patients (94%). Of 45 distinct tumor deposits found at operation, 67% were detected and localized with immunoscintigraphy while X-ray computed tomography and ultrasound visualized 53% and 23%, respectively.

  10. Machine learning with naturally labeled data for identifying abbreviation definitions.

    PubMed

    Yeganova, Lana; Comeau, Donald C; Wilbur, W John

    2011-06-09

    The rapid growth of biomedical literature requires accurate text analysis and text processing tools. Detecting abbreviations and identifying their definitions is an important component of such tools. Most existing approaches for the abbreviation definition identification task employ rule-based methods. While achieving high precision, rule-based methods are limited to the rules defined and fail to capture many uncommon definition patterns. Supervised learning techniques, which offer more flexibility in detecting abbreviation definitions, have also been applied to the problem. However, they require manually labeled training data. In this work, we develop a machine learning algorithm for abbreviation definition identification in text which makes use of what we term naturally labeled data. Positive training examples are naturally occurring potential abbreviation-definition pairs in text. Negative training examples are generated by randomly mixing potential abbreviations with unrelated potential definitions. The machine learner is trained to distinguish between these two sets of examples. Then, the learned feature weights are used to identify the abbreviation full form. This approach does not require manually labeled training data. We evaluate the performance of our algorithm on the Ab3P, BIOADI and Medstract corpora. Our system demonstrated results that compare favourably to the existing Ab3P and BIOADI systems. We achieve an F-measure of 91.36% on Ab3P corpus, and an F-measure of 87.13% on BIOADI corpus which are superior to the results reported by Ab3P and BIOADI systems. Moreover, we outperform these systems in terms of recall, which is one of our goals.

  11. Evaluation of the EIA system on the Island of Mauritius and development of an environmental monitoring plan framework

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ramjeawon, T.; Beedassy, R

    The Environment Protection Act (EPA) in Mauritius provides for the application of an EIA license in respect of undertakings listed in its first schedule. Following the promulgation of the Act in June 1993, the Department of Environment (DOE) is issuing an average of 125 EIA licenses yearly. In general, the review exercise of an environmental impact assessment (EIA) is terminated once the license has been granted. The aim of this project was to evaluate the EIA system in Mauritius and to identify its weaknesses and strengths. One of the main weaknesses, besides the lack of EIA audits, is the absencemore » of EIA follow-up monitoring. It is necessary to distinguish between monitoring done for regulatory purposes (compliance monitoring) and environmental monitoring related to the EIA. With the growth of the tourism industry on the island, coastal development projects have the potential to cause significant environmental impacts . A sample of EIA reports pertaining to this sector was assessed for its quality and follow-up mechanisms. Proposals for the contents of EIA Prediction Audits, Environmental Monitoring Plans (EMP) and the format for an EMP report are made.« less

  12. [EIA-IgG antibody measles prevention level estimated from measles neutralizing, particle agglutination and hemagglutination-inhibition antibody titer].

    PubMed

    Takayama, Naohide; Saika, Shizuko; Ichinohe, Sadato

    2009-09-01

    Measles hemagglutination inhibition (HI) antibody titer, widely used in clinical practice to simply and easily determine the measles immunity level has, in recent years, been increasingly replaced by measles IgG-antibody titer determined by enzyme-immunoassay (EIA). HI antibody titer appears to reflect this protective level, because HI measures the antibody against H protein required for the measles virus to adhere to host cells. EIA-IgG antibody titer does not correlate with the protective level, similar to particle agglutination (PA) titer, because EIA measures different antibodies, including those unrelated to measles protection. After determining HI, PA, neutralizing test (NT) results, and EIA-IgG antibody titer for individual specimens, we compared EIA-IgG antibody titer obtained using an EIA-Kit (Denka Seiken) to HI, PA, and NT titer with the following results: (1) Subjects with EIA-IgG titer of > or = 12.0 may be protected against measles: (2) Subjects with EIA-IgG titer of 4.0 to 8.0 appear to be protected insufficiently requiring a booster dose against measles: (3) Subjects with EIA-IgG titer of 8.0 to 12.0 may benefit from booster vaccination.

  13. Evaluation of the environmental impact assessment system in Syria

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haydar, F., E-mail: firashaydar@yahoo.co; Pediaditi, K., E-mail: kalliapediaditi@hotmail.co

    2010-11-15

    Syria is a country experiencing rapid change, undergoing a process of political and governance decentralisation, opening its markets to the private sector, and experiencing a rise in infrastructure development. In light of these economic growth targeted changes, knowledge of the status and capacity of the Syrian EIA system to ensure environmental protection becomes of paramount importance. Syria first introduced EIA as a Draft Decree in 1995, which was not formally adopted until 2008. To date, no structured evaluation of Syria's EIA system has been conducted, a knowledge gap addressed through this paper. The research presented herein comprises a review andmore » comparative evaluation of Syrian legislation and procedures, to the EU EIA Directive and World Bank Operational Directive, as well as a series of interviews with Syrian stakeholders involved in EIA implementation. The investigation concluded that the new EIA provisions provide a sound legal basis. From interviews however, it was ascertained that EIA implementation faces a number of barriers such as, a lack of EIA integration into existing decision making and licensing processes and persistent exclusion of public projects from EIA. A number of recommendations are proposed, perceived necessary for the enhancement of EIA implementation in Syria.« less

  14. Pretargeted Radioimmunotherapy Using Anti-CD45 Monoclonal Antibodies to Deliver Radiation to Murine Hematolymphoid Tissues and Human Myeloid Leukemia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pagel, John M.; Matthews, Dana C.; Kenoyer, Aimee L.

    2009-01-01

    The efficacy of radioimmunotherapy (RIT) for treatment of patients with hematological malignancies frequently fails because of disease recurrence. We therefore conducted pretargeted RIT studies to augment the efficacy in mice of therapy using a pretargeted anti-human (h)CD45 antibody (Ab)-streptavidin (SA) conjugate followed by delivery of a biotinylated clearing agent and radiolabeled-DOTA-biotin. Tumor-to-blood ratios at 24 hours were 20:1 using pretargeted anti-hCD45 RIT and <1:1 with conventional RIT. In vivo imaging studies confirmed that the pretargeted RIT approach provided high-contrast tumor images with minimal blood-pool activity, whereas directly-labeled anti-hCD45 Ab produced distinct tumor images but the blood pool retained a largemore » amount of labeled antibody for a prolonged time. Therapy experiments demonstrated that 90Y-DOTA-biotin significantly prolonged survival of mice treated pretargeted with anti-hCD45 Ab-SA compared to mice treated with conventional RIT using 90Y-labeled anti-hCD45 Ab at the maximally tolerated dose (400 µCi). Since human CD45 antigens are confined to xenograft tumor cells in this model, and all murine tissues are devoid of hCD45 and will not bind anti-hCD45 Ab, we also compared one-step and pretargeted RIT using an anti-murine (m)CD45 Ab (A20 ) in a model where the target antigen is present on normal hematopoietic tissues. After 24 hours, 27.3 ± 2.8% of the injected dose of radionuclide was delivered per gram (% ID/g) of lymph node using 131I-A20-Ab compared with 40.0 ± 5.4% ID/g for pretargeted 111In-DOTA-biotin (p value). These data suggest that multi-step pretargeted methods for delivering RIT are superior to conventional RIT when targeting CD45 for the treatment of leukemia and may allow for the intensification of therapy, while minimizing toxicities.« less

  15. Evaluation of dried blood spot protocols with the Bio-Rad GS HIV Combo Ag/Ab EIA and Geenius™ HIV 1/2 Supplemental Assay.

    PubMed

    Luo, Wei; Davis, Geoff; Li, LiXia; Shriver, M Kathleen; Mei, Joanne; Styer, Linda M; Parker, Monica M; Smith, Amanda; Paz-Bailey, Gabriela; Ethridge, Steve; Wesolowski, Laura; Owen, S Michele; Masciotra, Silvina

    2017-06-01

    FDA-approved antigen/antibody combo and HIV-1/2 differentiation supplemental tests do not have claims for dried blood spot (DBS) use. We compared two DBS-modified protocols, the Bio-Rad GS HIV Combo Ag/Ab (BRC) EIA and Geenius™ HIV-1/2 (Geenius) Supplemental Assay, to plasma protocols and evaluated them in the CDC/APHL HIV diagnostic algorithm. BRC-DBS p24 analytical sensitivity was calculated from serial dilutions of p24. DBS specimens included 11 HIV-1 seroconverters, 151 HIV-1-positive individuals, including 20 on antiretroviral therapy, 31 HIV-2-positive and one HIV-1/HIV-2-positive individuals. BRC-reactive specimens were tested with Geenius using the same DBS eluate. Matched plasma specimens were tested with BRC, an IgG/IgM immunoassay and Geenius. DBS and plasma results were compared using the McNemar's test. A DBS-algorithm applied to 348 DBS from high-risk individuals who participated in surveillance was compared to HIV status based on local testing algorithms. BRC-DBS detects p24 at a concentration 18 times higher than in plasma. In seroconverters, BRC-DBS detected more infections than the IgG/IgM immunoassay in plasma (p=0.0133), but fewer infections than BRC-plasma (p=0.0133). In addition, the BRC/Geenius-plasma algorithm identified more HIV-1 infections than the BRC/Geenius-DBS algorithm (p=0.0455). The DBS protocols correctly identified HIV status for established HIV-1 infections, including those on therapy, HIV-2 infections, and surveillance specimens. The DBS protocols exhibited promising performance and allowed rapid supplemental testing. Although the DBS algorithm missed some early infections, it showed similar results when applied to specimens from a high-risk population. Implementation of a DBS algorithm would benefit testing programs without capacity for venipuncture. Published by Elsevier B.V.

  16. Performance characteristics of an automated latex immunoturbidimetric assay [HemosIL® HIT-Ab(PF4-H)] for the diagnosis of immune heparin-induced thrombocytopenia.

    PubMed

    Warkentin, Theodore E; Sheppard, Jo-Ann I; Linkins, Lori-Ann; Arnold, Donald M; Nazy, Ishac

    2017-05-01

    Heparin-induced thrombocytopenia (HIT) is a prothrombotic drug reaction caused by platelet-activating anti-PF4/heparin antibodies. Given time-sensitive treatment considerations, a rapid and accurate laboratory test for HIT antibodies is needed. To determine operating characteristics for the HemosIL ® HIT-Ab (PF4/H) , a rapid, on-demand, fully-automated, latex immunoturbidimetric assay (LIA), for diagnosis of HIT. We evaluated LIA sensitivity, specificity, negative (NPV) and positive predictive value (PPV), negative (LR-) and positive likelihood ratio (LR+), using citrated-plasma from 429 patients (prospective cohort study of 4Ts scoring; HIT, n=31), and from consecutive HIT patients (n=125), using reference standard serotonin-release assay (SRA). Comparators included two PF4-dependent enzyme-immunoassays (EIAs). We used stratum-specific likelihood ratios (SSLRs) to determine how differing magnitudes of LIA-positivity influenced post-test probability of HIT. LIA operating characteristics were: sensitivity=97.4% (152/156); specificity=94.0% (374/398); PPV=55.6% (30/54); and NPV=99.7% (374/375). At manufacturers' cutoffs, LIA specificity and PPV were superior to the EIAs. Although a negative LIA pointed strongly against HIT (LR-, 0.034), the post-test probability was ~2% with high 4Ts score. The LIA's LR+ was high (16.0), with SSLRs rising substantially with greater LIA-positivity: 5.7 (1.0-4.9U/mL), 31 (5.0-15.9U/mL), and 128 (≥16U/mL). A LIA-positive result (at 1.0 cutoff) indicated at least 24% HIT probability (low 4Ts score), rising to 90% with high 4Ts score. Although approximately 1 in 40 SRA-positive patients tested LIA-negative, the LIA's high NPV and PPV indicate that this rapid assay is useful for the diagnostic evaluation of HIT, including in low pre-test situations. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  17. Tyr phosphatase-mediated P-ERK inhibition suppresses senescence in EIA + v-raf transformed cells, which, paradoxically, are apoptosis-protected in a MEK-dependent manner.

    PubMed

    De Vitis, Stefania; Sonia Treglia, Antonella; Ulianich, Luca; Turco, Stefano; Terrazzano, Giuseppe; Lombardi, Angela; Miele, Claudia; Garbi, Corrado; Beguinot, Francesco; Di Jeso, Bruno

    2011-02-01

    Activation of the Ras-Raf-extracellular signal-regulated kinase (ERK) pathway causes not only proliferation and suppression of apoptosis but also the antioncogenic response of senescence. How these contrasting effects are reconciled to achieve cell transformation and cancer formation is poorly understood. In a system of two-step carcinogenesis (dedifferentiated PC EIA, transformed PC EIA-polyoma-middle T [PC EIA + Py] and PC EIA-v-raf [PC EIA + raf] cells], v-raf cooperated with EIA by virtue of a strong prosurvival effect, not elicited by Py-middle T, evident toward serum-deprivation-and H(2)O(2)-induced apoptosis. Apoptosis was detected by DNA fragmentation and annexin V staining. The prosurvival function of v-raf was, in part, mitogen-activated protein kinase/ERK kinase (MEK)-dependent, as shown by pharmacological MEK inhibition. The MEK-dependent antiapoptotic effect of v-raf was exerted despite a lower level of P-ERK1/2 in EIA + raf cells with respect to EIA + Py/EIA cells, which was dependent on a high tyrosine phosphatase activity, as shown by orthovanadate blockade. An ERK1/2 tyrosine phosphatase was likely involved. The high tyrosine phosphatase activity was instrumental to the complete suppression of senescence, detected by β-galactosidase activity, because tyrosine phosphatase blockade induced senescence in EIA + raf but not in EIA + Py cells. High tyrosine phosphatase activity and evasion from senescence were confirmed in an anaplastic thyroid cancer cell line. Therefore, besides EIA, EIA + raf cells suppress senescence through a new mechanism, namely, phosphatase-mediated P-ERK1/2 inhibition, but, paradoxically, retain the oncogenic effects of the Raf-ERK pathway. We propose that the survival effect of Raf is not a function of absolute P-ERK1/2 levels at a given time but is rather dynamically dependent on greater variations after an apoptotic stimulus.

  18. Ultrasensitive electrochemical immunosensors for multiplexed determination using mesoporous platinum nanoparticles as nonenzymatic labels.

    PubMed

    Cui, Zhentao; Wu, Dan; Zhang, Yong; Ma, Hongmin; Li, He; Du, Bin; Wei, Qin; Ju, Huangxian

    2014-01-07

    An ultrasensitive multiplexed immunoassay method was developed at a disposable immunosensor array using mesoporous platinum nanoparticles (M-Pt NPs) as nonenzymatic labels. M-Pt NPs were prepared by ultrasonic method and employed to label the secondary antibody (Ab2) for signal amplification. The immunosensor array was constructed by covalently immobilizing capture antibody (Ab1) on graphene modified screen printed carbon electrodes (SPECs). After the sandwich-type immunoreactions, the M-Pt-Ab2 was bound to immunosensor surface to catalyze the electro-reduction of H2O2 reaction, which produced detectable signals for readout of analytes. Using breast cancer related panel of tumor markers (CA125, CA153 and CEA) as model analytes, this method showed wide linear ranges of over 4 orders of magnitude with the detection limits of 0.002 U mL(-1), 0.001 U mL(-1) and 7.0 pg mL(-1) for CA125, CA153 and CEA, respectively. The disposable immunosensor array possessed excellent clinical value in cancer screening as well as convenient point of care diagnostics. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. An evaluation framework for effective public participation in EIA in Pakistan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nadeem, Obaidullah, E-mail: obaidnadeem@yahoo.co; Fischer, Thomas B., E-mail: fischer@liverpool.ac.u

    2011-01-15

    Evaluating the effectiveness of public participation in EIA related decisions is of crucial importance for developing a better understanding of overall EIA effectiveness. This paper aims to contribute to the professional debate by establishing a country specific evaluation framework for Pakistan, which, it is suggested, could also potentially be used in other developing countries. The framework is used to evaluate performance of public participation in EIA in terms of 40 attributes for four selected projects from the province of Punjab. The evaluation is based on interviews with stakeholders, review of EIA reports as well as public hearing proceedings and environmentalmore » approval conditions. The evaluation of the selected projects revealed an overall weak influence of public participation on substantive quality of EIA and on the final decision. Overall, EIA public participation has succeeded in providing a more egalitarian environment. Furthermore, it appears fair to say that sufficient time for submitting written comments on EIA reports as well as for raising concerns during public hearings had been given. Also, public consultation was significantly contributing to educating participants. Despite some impediments, it is argued that public participation in EIA is gradually gaining ground in Pakistan. Recommendations to enhance EIA public participation effectiveness in Pakistan include applying a more proactive approach which should take place before EIA is conducted and before site selection for development projects is happening.« less

  20. Trifunctional conjugation reagents. Reagents that contain a biotin and a radiometal chelation moiety for application to extracorporeal affinity adsorption of radiolabeled antibodies.

    PubMed

    Wilbur, D Scott; Chyan, Ming-Kuan; Hamlin, Donald K; Kegley, Brian B; Nilsson, Rune; Sandberg, Bengt E B; Brechbiel, Martin

    2002-01-01

    A method of removing radiolabeled monoclonal antibodies (mAbs) from blood using a device external to the body, termed extracorporeal affinity-adsorption (EAA), is being evaluated as a means of decreasing irradiation of noncancerous tissues in therapy protocols. The EAA device uses an avidin column to capture biotinylated-radiolabeled mAbs from circulated blood. In this investigation, three trifunctional reagents have been developed to minimize the potential deleterious effect on antigen binding brought about by the combination of radiolabeling and biotinylation of mAbs required in the EAA approach. The studies focused on radiolabeling with (111)In and (90)Y, so the chelates CHX-A' '-DTPA and DOTA, which form stable attachments to these radionuclides, were incorporated in the trifunctional reagents. The first trifunctional reagent prepared did not incorporate a group to block the biotin cleaving enzyme biotinidase, but the two subsequent reagents coupled aspartic acid to the biotin carboxylate for that purpose. All three reagents used 4,7,10-trioxa-1,13-tridecanediamine as water-soluble spacers between an aminoisophthalate core and the biotin or chelation group. The mAb conjugates were radioiodinated to evaluate cell binding as a function of substitution. Radioiodination was used so that a direct comparison with unmodified mAb could be made. Evaluation of the number of conjugates per antibody versus cell binding immunoreactivities indicated that minimizing the number of conjugates was best. Interestingly, a decrease of radioiodination yield as a function of the number of isothiocyanate containing conjugates per mAb was noted. The decreased yields were presumably due to the presence of thiourea functionality formed in the conjugation reaction. Radiolabeling with (111)In and (90)Y was facile at room temperature for conjugates containing the CHX-A' ', but elevated temperature (e.g., 45 degrees C) was required to obtain good yields with the DOTA chelate. Stability of (90)Y labeled mAb in serum, and when challenged with 10 mM EDTA, was high. However, challenging the (90)Y labeled mAb with 10 mM DTPA demonstrated high stability for the DOTA containing conjugate, but low stability for the CHX-A' ' containing conjugate. Thus, the choice between these two chelating moieties might be made on requirements for facile and gentle labeling versus very high in vivo stability. Application of the trifunctional biotinylation reagents to the blood clearance of labeled antibodies in EAA is under investigation. The new reagents may also be useful for other applications.

  1. Environmental impact assessment in Sri Lanka: A progress report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Butler, J.W.

    1995-12-01

    The paper reports on progress by the Government of Sri Lanka in the implementation of a formal environmental impact assessment (EIA) requirement. The authors have recently conducted several activities in Sri Lanka intended to improve the analytical quality of EIA documents and the utility of the EIA process in government decisionmaking, with particular attention to the use of programmatic or sectoral EIAs. The U.S. Agency for International Development established a 5-year project, the Natural Resources and Environmental Policy Project (NAREPP), to provide training and technical assistance in EIA and related disiplines for the Central Environmental Authority (CEA), several other Srimore » Lanka government agencies, and the private sector. This activity has involved efforts to expand the technical expertise within Sri Lanka for conducting EIA, which include developing EIA courses and materials in cooperation with several universities and conducting intensive training programs for both government and private-sector environmental professionals. This EIA will focus on the selection of government-approved industrial estates throughout the country, on which most new industrial development projects are to be located. Further training programs in the use of current analytical methodologies for EIA were also developed and conducted. The effectiveness of these activities can be assessed by evaluating changes in the content and quality of subsequent EIA documents and in the extent to which such documents affect environmental decisionmaking in Sri Lanka. The authors discuss the role of the programmatic EIA in the industrial development program of Sri Lanka, remaining constraints on the EIA process, and recommendations for further improvement.« less

  2. Chemotherapeutic Effect of CD147 Antibody-labeled Micelles Encapsulating Doxorubicin Conjugate Targeting CD147-Expressing Carcinoma Cells.

    PubMed

    Asakura, Tadashi; Yokoyama, Masayuki; Shiraishi, Koichi; Aoki, Katsuhiko; Ohkawa, Kiyoshi

    2018-03-01

    CD147 (basigin/emmprin) is expressed on the surface of carcinoma cells. For studying the efficacy of CD147-targeting medicine on CD147-expressing cells, we studied the effect of anti-CD147-labeled polymeric micelles (CD147ab micelles) that encapsulated a conjugate of doxorubicin with glutathione (GSH-DXR), with specific accumulation and cytotoxicity against CD147-expressing A431 human epidermoid carcinoma cells, Ishikawa human endometrial adenocarcinoma cells, and PC3 human prostate carcinoma cells. By treatment of each cell type with CD147ab micelles for 1 h, a specific accumulation of CD147ab micelles in CD147-expressing cells was observed. In addition, the cytotoxicity of GSH-DXR-encapsulated micelles against each cell type was measured by treatment of the micelles for 1 h. The cytotoxic effect of CD147ab micelles carrying GSH-DXR was 3- to 10-fold higher for these cells than that of micelles without GSH-DXR. These results suggest that GSH-DXR-encapsulated CD147ab micelles could serve as an effective drug delivery system to CD147-expressing carcinoma cells. Copyright© 2018, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  3. Immunocytochemistry by electron spectroscopic imaging using a homogeneously boronated peptide.

    PubMed

    Kessels, M M; Qualmann, B; Klobasa, F; Sierralta, W D

    1996-05-01

    A linear all-L-oligopeptide containing five carboranyl amino acids (corresponding to 50 boron atoms) was synthesized and specifically attached to the free thiol group of monovalent antibody fragments F(ab)'. The boronated immunoreagent was used for the direct post-embedding detection of somatotrophic hormone in ultrathin sections of porcine pituitary embedded in Spurr resin. The specific boron-labelling of secretory vesicles in somatotrophs was detected by electron spectroscopic imaging and confirmed by conventional immunogold labelling run in parallel. In comparison with immunogold, boron-labelled F(ab)'-fragments showed higher tagging frequencies, as was expected; the small uncharged immunoreagents have an elongated shape and carry the antigen-combining structure and the detection tag at opposite ends, thus allowing for high spatial resolution in electron spectroscopic imaging.

  4. Analysis of environmental impact assessment (EIA) system in Turkey.

    PubMed

    Coşkun, Aynur Aydın; Turker, Ozhan

    2011-04-01

    The Environmental Impact Assessment (EIA) System, which embodies the "prevention principle" of the environmental law, is an important tool for environmental protection. This tool has a private importance for Turkey since it is a developing country, and it entered the Turkish law in 1983 with the Environmental Law. Besides, the EIA Regulation, which shows the application principles, became effective in 1993. Because Turkey is a candidate for European Union (EU), the EIA Regulation has been changed due to the EU compliance procedure, and its latest version became valid in 2008. This study aims to emphasize The EIA system in Turkey to supervise the efficiency of this procedure and point the success level. In the introduction part, general EIA concept, its importance, and some notations are mentioned. Following that, the legislation, which builds the EIA system, has been analyzed starting from the 1982 Turkish Constitution. Then, the legislation rules are explained due to the basic steps of the EIA procedure. In order to shed light upon the application, the EIA final decisions given until today, the results, and their distributions to the industries are assessed. In the final part of the study, a SWOT analysis is made to mention the weaknesses, strengths, opportunities, and threats of the EIA system in Turkey.

  5. Surface binding properties of aged and fresh (recently excreted) Toxoplasma gondii oocysts

    USDA-ARS?s Scientific Manuscript database

    The surface properties of aged (stored for 10 years) and fresh (recently excreted) oocysts of Toxoplasma gondii were investigated using monoclonal antibody (mAb) and lectin-binding assays. Fresh oocysts bound a wall-specific mAb labeled with fluorescein isothiocyanate while aged oocysts did not. In ...

  6. Exploration of two-dimensional bio-functionalized phosphorene nanosheets (black phosphorous) for label free haptoglobin electro-immunosensing applications

    NASA Astrophysics Data System (ADS)

    Tuteja, Satish K.; Neethirajan, Suresh

    2018-04-01

    We report on the development of an antibody-functionalized interface based on electrochemically active liquid-exfoliated two-dimensional phosphorene (Ph) nanosheets—also known as black phosphorous nanosheets—for the label-free electrochemical immunosensing of a haptoglobin (Hp) biomarker, a clinical marker of severe inflammation. The electrodeposition has been achieved over the screen-printed electrode (SPE) using liquid-assisted ultrasonically exfoliated black phosphorus nanosheets. Subsequently, Ph-SPEs bioconjugated with Hp antibodies (Ab), using electrostatic interactions via a poly-L-lysine linker for biointerface development. Electrochemical analysis demonstrates that the Ab-modified Ph-SPEs (Ab@Ph-SPE) exhibit enhanced electroconducting behavior as compared to the pristine electrodes. This Ab-functionalized phosphorene-based electrochemical immunosensor platform has demonstrated remarkable sensitivity and specificity, having a dynamic linear response range from 0.01-10 mg ml-1 for Hp in standard and serum samples with a low detection limit (˜0.011 mg ml-1) using the label-free electrochemical technique. The sensor electrodes were also studied with other closely relative interferents to investigate cross reactivity and specificity. This strategy opens up avenues to POC (point-of-care) and on-farm livestock disease monitoring technologies for multiplexed diagnosis in complex biological samples such as serum. The technique is simple in fabrication and provides an analytical response in less than 60 s.

  7. Comparison between the two-step and the three-step algorithms for the detection of toxigenic Clostridium difficile.

    PubMed

    Qutub, M O; AlBaz, N; Hawken, P; Anoos, A

    2011-01-01

    To evaluate usefulness of applying either the two-step algorithm (Ag-EIAs and CCNA) or the three-step algorithm (all three assays) for better confirmation of toxigenic Clostridium difficile. The antigen enzyme immunoassays (Ag-EIAs) can accurately identify the glutamate dehydrogenase antigen of toxigenic and nontoxigenic Clostridium difficile. Therefore, it is used in combination with a toxin-detecting assay [cell line culture neutralization assay (CCNA), or the enzyme immunoassays for toxins A and B (TOX-A/BII EIA)] to provide specific evidence of Clostridium difficile-associated diarrhoea. A total of 151 nonformed stool specimens were tested by Ag-EIAs, TOX-A/BII EIA, and CCNA. All tests were performed according to the manufacturer's instructions and the results of Ag-EIAs and TOX-A/BII EIA were read using a spectrophotometer at a wavelength of 450 nm. A total of 61 (40.7%), 38 (25.3%), and 52 (34.7%) specimens tested positive with Ag-EIA, TOX-A/BII EIA, and CCNA, respectively. Overall, the sensitivity, specificity, negative predictive value, and positive predictive value for Ag-EIA were 94%, 87%, 96.6%, and 80.3%, respectively. Whereas for TOX-A/BII EIA, the sensitivity, specificity, negative predictive value, and positive predictive value were 73.1%, 100%, 87.5%, and 100%, respectively. With the two-step algorithm, all 61 Ag-EIAs-positive cases required 2 days for confirmation. With the three-step algorithm, 37 (60.7%) cases were reported immediately, and the remaining 24 (39.3%) required further testing by CCNA. By applying the two-step algorithm, the workload and cost could be reduced by 28.2% compared with the three-step algorithm. The two-step algorithm is the most practical for accurately detecting toxigenic Clostridium difficile, but it is time-consuming.

  8. Evaluation of a Newly Developed Lateral Flow Immunoassay for the Diagnosis of Cryptococcosis

    PubMed Central

    Lindsley, Mark D.; Mekha, Nanthawan; Baggett, Henry C.; Surinthong, Yupha; Autthateinchai, Rinrapas; Sawatwong, Pongpun; Harris, Julie R.; Park, Benjamin J.; Chiller, Tom; Poonwan, Natteewan

    2011-01-01

    Background. Cryptococcosis is a common opportunistic infection of human immunodeficiency virus (HIV)–infected individuals mostly occurring in resource-limited countries. This study compares the performance of a recently developed lateral flow immunoassay (LFA) to blood culture and enzyme immunoassay (EIA) for the diagnosis of cryptococcosis. Methods. Archived sera from 704 HIV-infected patients hospitalized for acute respiratory illness in Thailand were tested for cryptococcal antigenemia using EIA. All EIA-positive and a subset of EIA-negative sera were tested by LFA, with results recorded after 5 and 15 minutes incubation. Urine from patients with LFA- and EIA-positive sera was tested by LFA. Antigen results from patients with positive cryptococcal blood cultures were compared. Results. Of 704 sera, 92 (13%) were positive by EIA; among the 91 EIA-positive sera tested by LFA, 82 (90%) and 87 (96%) were LFA positive when read after 5 and 15 minutes, respectively. Kappa agreement of EIA and LFA for sera was 0.923 after 5 minutes and 0.959 after 15 minutes, respectively. Two of 373 EIA-negative sera were LFA positive at both time points. Of 74 urine specimens from EIA-positive patients, 52 (70.3%) were LFA positive. EIA was positive in 16 of 17 sera from blood culture–positive patients (94% sensitivity), and all sera were positive by LFA (100% sensitivity). Conclusions. A high level of agreement was shown between LFA and EIA testing of serum. The LFA is a rapid, easy-to-perform assay that does not require refrigeration, demonstrating its potential usefulness as a point-of-care assay for diagnosis of cryptococcosis in resource-limited countries. PMID:21810743

  9. Progressing quality control in environmental impact assessment beyond legislative compliance: An evaluation of the IEMA EIA Quality Mark certification scheme

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bond, Alan, E-mail: alan.bond@uea.ac.uk; Research Unit for Environmental Sciences and Management, North-West University; Fischer, Thomas B, E-mail: fischer@liverpool.ac.uk

    The effectiveness of Environmental Impact Assessment (EIA) systems is contingent on a number of control mechanisms: procedural; judicial; evaluative; public and government agency; professional; and development aid agency. If we assume that procedural and judicial controls are guaranteed in developed EIA systems, then progressing effectiveness towards an acceptable level depends on improving the performance of other control mechanisms over time. These other control mechanisms are either absent, or are typically centrally controlled, requiring public finances; this we argue is an unpopular model in times of greater Government austerity. Here we evaluate a market-based mechanism for improving the performance of evaluativemore » and professional control mechanisms, the UK Institute of Environmental Management and Assessments' EIA Quality Mark. We do this by defining dimensions of effectiveness for the purposes of our evaluation, and by identifying international examples of the approaches taken to delivering the other control measures to validate the approach taken in the EIA Quality Mark. We then evaluate the EIA Quality Mark, when used in combination with legal procedures and an active judiciary, against the effectiveness dimensions and use time-series analysis of registrant data to examine its ability to progress practice. We conclude that the EIA Quality Mark has merit as a model for a market-based mechanism, and may prove a more financially palatable approach for delivering effective EIA in mature systems in countries that lack centralised agency oversight. It may, therefore, be of particular interest to some Member States of the European Union for ensuring forthcoming certification requirements stemming from recent amendments to the EIA Directive. - Highlights: • Quality control mechanisms in EIA are identified. • Effectiveness of EIA is conceptualised for evaluation purposes. • The UK IEMA EIA Quality Mark is introduced as a market-based mechanism. • The EIA Quality Mark is found to progress quality in many, but not all, areas.« less

  10. Environmental Impact Assessment in the Visegrad Group countries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gałaś, Slávka, E-mail: sgalas@geol.agh.edu.pl; Gałaś, Andrzej, E-mail: pollux@geol.agh.edu.pl; Zeleňáková, Martina, E-mail: martina.zelenakova@tuke.sk

    Highlights: • Comparison and evaluation of EIA systems in the V4 countries are presented. • Strengths and weaknesses of EIA systems based on a questionnaire survey are stated. • The function and efficiency of the EIA application in the V4 countries are analysed. • Irregularities and shortcomings of EIA systems in the V4 should be eliminated. The Environmental Impact Assessment Directive (EIA Directive) has created a reference framework for the implementation of the system of Environmental Impact Assessment (EIA) into the legal systems of the Member States of the European Union, including the countries belonging to the Visegrad Group (V4):more » Poland, Slovakia, the Czech Republic and Hungary. The Directive was the basis for the introduction of compulsory stages of the EIA process in the V4. The stages were then adapted to national requirements, including thresholds of the qualifying criteria of projects at the screening and scoping stages. The EIA system in the analysed countries has been growing, changing and being modified together with the political and economic changes of the last 30 years. Although all Visegrad Group countries are members of the EU and should harmonize the provisions of the EIA Directive and its amendments, there still exist singularities in each country's national EIA legislation, in terms of complementarities among the V4 countries, access to information resources, protection of natural resources, mitigation of socio-environmental impacts, or transboundary impact assessment. The article compares and evaluates the EIA systems in the four countries, specifies similarities and differences in the implementation of administrative proceedings and points out opportunities to strengthen the system. It presents selected results of a study conducted in 2013 within the framework of the international project “Assessment of the quality of the environment in the V4 Countries” (AQE V4). This paper indicates examples of good practice in the EIA systems and the obtained results are compared regarding the amendments to the current European Union EIA Directive.« less

  11. 78 FR 14521 - Agency Information Collection Extension With Changes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-06

    ...-411, ``Coordinated Bulk Power Supply Program Report,'' Form EIA-826, ``Monthly Electric Utility Sales and Revenue Report with State Distributions,'' Form EIA-860, ``Annual Electric Generator Report,'' Form EIA-860M, ``Monthly Update to the Annual Electric Generator Report,'' Form EIA-861, ``Annual...

  12. 77 FR 13313 - Agency Information Collection Extension

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-06

    ...;'' EIA-782A, ``Refiners'/Gas Plant Operators' Monthly Petroleum Product Sales Report;'' EIA-782C, ``Monthly Report of Prime Supplier Sales of Petroleum Products Sold For Local Consumption;'' EIA-821, ``Annual Fuel Oil and Kerosene Sales Report;'' EIA-856, ``Monthly Foreign Crude Oil Acquisition Report...

  13. Comparison of enzyme immunoassays for antibodies to Haemophilus ducreyi in a community outbreak of chancroid in the United States.

    PubMed

    Chen, C Y; Mertz, K J; Spinola, S M; Morse, S A

    1997-06-01

    The performance of two EIAs (adsorption EIA and lipooligosaccharide [LOS] EIA) that detect antibodies to Haemophilus ducreyi was evaluated with serum specimens obtained from 163 patients (96 with genital ulcer disease [GUD]). Paired serum specimens (initial and follow-up) were obtained from 52 of the GUD patients. By use of initial serum specimens from 82 GUD patients whose etiologic agents for their ulcers had been identified, the adsorption EIA had a sensitivity and specificity for chancroid of 53% and 71%, while the LOS EIA had a sensitivity and specificity of 48% and 89%, respectively. Sensitivity and specificity of the adsorption EIA increased to 78% and 84%, respectively, when the results of follow-up serum specimens were used to calculate optimal performance. The proportion of patients testing positive for H. ducreyi who had anti-H. ducreyi IgG antibodies, as determined by adsorption EIA, increased with the duration of infection, thus limiting the role of EIAs in the diagnosis of chancroid.

  14. Controls on project proponents and environmental impact assessment effectiveness

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ortolano, L.

    The degree of effectiveness of environmental impact assessment (EIA) for particular projects is associated with the existence of mechanisms of organizational control. Five dimensions of EIA effectiveness are considered: procedural compliance, completeness of EIA documents, methods to assess impacts, influence on project decisions, and weight given to environmental factors. Six mechanisms of control are introduced and illustrated by programs and projects in several countries. Experience in the Philippines under President Marcos demonstrates that procedural control in the form of EIA regulations, when used without other control mechanisms, will lead at most to token compliance. Judicial control, as practiced in themore » US, yields high procedural compliance. Evaluative control can yield effective EIA, but some systems based on this form of control treat only a small fraction of the major projects proposed. Both control exerted by development assistance organizations and control by professionals have great potential for yielding effective EIA, but that potential has not been fully realized. Control exerted directly by citizens or agencies not otherwise involved in EIA is uncommon, but cases from Taiwan demonstrate that those controls can be significant. An understanding of relationships between control mechanisms and EIA effectiveness is useful in designing EIA policies and programs.« less

  15. 78 FR 53135 - Agency Information Collection Extension

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-28

    ... Synfuel data Minor revisions to instructions and definitions Form EIA-7A: Coal Production and Preparation... Production and Preparation Report;'' EIA-8A ``Coal Stocks Report;'' EIA-20 ``Weekly Coal Monitoring Report... environment. EIA surveys are conducted to collect coal market data. The data elements include production...

  16. Consideration of climate change impacts and adaptation in EIA practice — Perspectives of actors in Austria and Germany

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jiricka, Alexandra, E-mail: alexandra.jiricka@boku.ac.at; Department of Landscape, Spatial and Infrastructure Sciences, Institute for Landscape Development, Recreation and Conservation Planning, Peter-Jordan-Straße 82, 1190 Vienna; Formayer, Herbert

    Current political discussions and developments indicate the importance and urgency of incorporating climate change considerations into EIA processes. The recent revision of the EU Directive 2014/52/EU on Environmental Impact Assessment (EIA) requires changes in the EIA practice of the EU member states. This paper investigates the extent to which the Environmental Impact Assessment (EIA) can contribute to an early consideration of climate change consequences in planning processes. In particular the roles of different actors in order to incorporate climate change impacts and adaptation into project planning subject to EIA at the appropriate levels are a core topic. Semi-structured expert interviewsmore » were carried out with representatives of the main infrastructure companies and institutions responsible in these sectors in Austria, which have to carry out EIA regularly. In a second step expert interviews were conducted with EIA assessors and EIA authorities in Austria and Germany, in order to examine the extent to which climate-based changes are already considered in EIA processes. This paper aims to discuss the different perspectives in the current EIA practice with regard to integrating climate change impacts as well as barriers and solutions identified by the groups of actors involved, namely project developers, environmental competent authorities and consultants (EIA assessors/practitioners). The interviews show that different groups of actors consider the topic to different degrees. Downscaling of climate change scenarios is in this context both, a critical issue with regards to availability of data and costs. Furthermore, assistance for the interpretation of relevant impacts, to be deducted from climate change scenarios, on the specific environmental issues in the area is needed. The main barriers identified by the EIA experts therefore include a lack of data as well as general uncertainty as to how far climate change should be considered in the process without reliable data but in the presence of knowledge about possible consequences at an abstract level. A joint strategy on how to cope with uncertain prognoses about main impacts on environmental issues for areas without reliable data requires a discussion and cooperation between EIA consultants and environmental authorities. - Highlights: • The consideration of climate change impacts in EIA practice in Austria and Germany was analysed through expert interviews. • Barriers as well as possible solutions were indentified by the different groups of actors involved in EIA. • The main challenges regard the investigation of specific entry points. • Limits of feasibility need to be discussed amongst the different groups of actors.« less

  17. RP-UHPLC-UV-ESI-MS/MS analysis of LPMO generated C4-oxidized gluco-oligosaccharides after non-reductive labeling with 2-aminobenzamide.

    PubMed

    Frommhagen, Matthias; van Erven, Gijs; Sanders, Mark; van Berkel, Willem J H; Kabel, Mirjam A; Gruppen, Harry

    2017-08-07

    Lytic polysaccharide monooxygenases (LPMOs) are able to cleave recalcitrant polysaccharides, such as cellulose, by oxidizing the C1 and/or C4 atoms. The analysis of the resulting products requires a variety of analytical techniques. Up to now, these techniques mainly focused on the identification of non-oxidized and C1-oxidized oligosaccharides. The analysis of C4-oxidized gluco-oligosaccharides is mostly performed by using high pressure anion exchange chromatography (HPAEC). However, the alkaline conditions used during HPAEC analysis lead to tautomerization of C4-oxidized gluco-oligosaccharides, which limits the use of this technique. Here, we describe the use of reverse phase-ultra high performance liquid chromatography (RP-UHPLC) in combination with non-reductive 2-aminobenzamide (2-AB) labeling. Non-reductive 2-AB labeling enabled separation of C4-oxidized gluco-oligosaccharides from their non-oxidized counterparts. Moreover, RP-UHPLC does not require buffered mobile phases, which reduce mass spectrometry (MS) sensitivity. The latter is seen as an advantage over other techniques such as hydrophilic interaction liquid chromatography and porous graphitized carbon coupled to MS. RP-UHPLC coupled to UV detection and mass spectrometry allowed the identification of both labeled non-oxidized and C4-oxidized oligosaccharides. Non-reductive labeling kept the ketone at the C4-position of LPMO oxidized oligosaccharides intact, while selective reducing agents such as sodium triacetoxyborohydride (STAB) reduced this ketone group. Our results show that RP-UHPLC-UV-ESI-MS in combination with non-reductively 2-AB labeling is a suitable technique for the separation and identification of LPMO-generated C4-oxidized gluco-oligosaccharides. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zining, Jin, E-mail: jinzn@pkusz.edu.cn

    The article explores the practices of Environmental Impact Assessment (EIA) Law in China's courts by examining 107 judicial decisions. Each of the 107 judicial decisions has been analyzed to determine the time/location of the decision, what type of EIA document was referred to, what specific claim was made by the plaintiffs, and what the court's ruling was on the case. The results indicate that: unlike in Germany or Japan, all kinds of EIA decisions made by environment protect bureaus (EPBs) in China were widely taken as justiciable, and China's courts generally allowed local residents to have standing and thus challengemore » the EPBs' decisions made during the EIA process. On the other hand, the research also shows the EPBs overwhelmingly prevailed in those EIA lawsuits. It is also found that China's reviewing judges were highly self-restrained, giving obvious deference to the technocrat with the substantial contents of EIA documents. Also, the concept of “flaw” was created when it came to procedural issues. These two factors, among others, were both helping the EPBs' prevailing successes. - Highlights: • 107 judicial decisions referring to China's EIA law are examined. • The justiciability of EPB's EIA decisions were taken for granted. • The defenders overwhelmingly prevailed in those EIA lawsuits. • The reviewing judges were highly self-restrained, defering to the technocrat with the EIA documents. • A functional concept, “flaw”, was created by reviewing judges when it came to procedural issues.« less

  19. Variations of TEC near the Indian Equatorial Ionospheric anomaly (EIA) stations by GPS measurements during descending phase of solar activity (2005 -2009)

    NASA Astrophysics Data System (ADS)

    Kumar, Sanjay; Singh, Abhay Kumar

    The dual frequency Global Positioning System (GPS) data recorded at Varanasi (geographic latitude 250, 16 N longitude 820, 59 E) and Kanpur (geographic latitude 260, 30 N longitude 800, 12 E) stations, near the equatorial ionosphere anomaly (EIA) in India, have been analyzed to retrieve total electron content (TEC). The daily peak value of vertical total electron content (VTEC) has been utilized to study the variability of EIA. Present paper studied monthly, seasonal and annual variations as well as solar and geomagnetic effects on EIA. It has been found that EIA yield their maximum values during the equinox months and minimum during summer and winter. The correlations of EIA with solar as well as geomagnetic indices have been also discussed. Key words: Total electron contents (TECs), EIA, GPS.

  20. EIA's Role in Energy Data Collection, With Some Notes on Water Data

    NASA Astrophysics Data System (ADS)

    Leckey, T. J.

    2017-12-01

    The U.S. Energy Information Administration (EIA) is the statistical and analytical agency within the U.S. Department of Energy. EIA collects, analyzes, and disseminates independent and impartial energy information to promote sound policymaking, efficient markets, and public understanding of energy and its interaction with the economy and the environment. EIA conducts a comprehensive data collection program that covers the full spectrum of energy sources, end uses, and energy flows. This presentation will describe EIA's authority to collect energy data, report on the range of energy areas currently collected by EIA, discuss some areas where energy information and water issues intersect, and describe the relatively few areas where EIA does collect a small amount of water data. The presentation will conclude with some thoughts about necessary components for effective collection of water data at the federal level.

  1. Evaluation of a Commercial Glycoprotein Enzyme-Linked Immunosorbent Assay for Measuring Vaccine Immunity to Varicella

    PubMed Central

    Kim, Yun Hwa; Hwang, Ji Young; Shim, Hye Min; Lee, Eunsil; Park, Songyong

    2014-01-01

    Purpose To evaluate a recently marketed commercial glycoprotein enzyme-linked immunosorbent assay (gpEIA) kit, the VaccZyme™ VZV gpEIA, for measuring the immunity of varicella-vaccinated children. Materials and Methods We investigated the accuracy and reproducibility of the VaccZyme™ VZV gpEIA kit for the detection of antibodies to VZV. We also examined the sensitivity, specificity, and correlation between antibody titers calculated with gpEIA versus fluorescent antibody to membrane antigen (FAMA) by using sera of 349 children, ranging from 1 to 6 years old. Results VaccZyme™ VZV gpEIA gave precise and reproducible intra- and inter-assay results. FAMA and gpEIA titers showed a linear correlation (Pearson correlation coefficient=0.987). The sensitivity and specificity of the VaccZyme™ gpEIA was 31.4% and 100%, respectively, when the guidelines of the gpEIA (<100 mIU/mL) and FAMA 1:4 were adopted as cutoff values. However, the maximum sensitivity and specificity were 88.9% and 95.1%, respectively, with the highest correlation (κ=0.840), if the cutoff values were set with gpEIA at 49.7 mIU/mL and FAMA 1:16. Conclusion These results demonstrate that the VaccZyme™ VZV gpEIA kit gave precise and reproducible data for measuring antibody titer after varicella vaccination. The results also showed that the antibody titer calculated with the VaccZyme™ gpEIA kit strongly correlated with the FAMA titer. However, cutoff values should be re-optimized for the evaluation of vaccine immunity. PMID:24532518

  2. Geography, Planning and EIA.

    ERIC Educational Resources Information Center

    Morgan, R . K.

    1987-01-01

    Defines Environmental Impact Assessment (EIA) as a major tool for environmental management throughout the world. Provides background to the EIA concept and describes how it might be used within secondary school geography as an integrative teaching device. Special emphasis is given to the new EIA/Seventh-Form syllabus currently being used in New…

  3. 75 FR 17702 - Agency Information Collection Activities: Proposed Collection; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-07

    ... Forms: EIA-63A, ``Annual Solar Thermal Collector/Reflector Shipments Report.'' EIA-63B, ``Annual...://www.eia.doe.gov/cneaf/solar.renewables/page/fed_register/renewable_2011.html . SUPPLEMENTARY...) under Section 3507(a) of the Paperwork Reduction Act of 1995. Form EIA-63A, ``Annual Solar Thermal...

  4. 75 FR 25221 - Agency Information Collection Activities: Proposed Collection; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-07

    ..., ``Monthly Natural Gas Liquids Report,'' EIA-817, ``Monthly Tanker and Barge Movement Report,'' EIA-819... inventories for natural gas plant liquids and liquefied refinery gases, propane (including propylene... hours; EIA-816, ``Monthly Natural Gas Liquids Report,''--0.95 hours; EIA-817, ``Monthly Tanker and Barge...

  5. Environmental impact assessment: Retrospect and prospect

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jay, Stephen; Jones, Carys; Slinn, Paul

    2007-05-15

    The widespread experience of environmental impact assessment (EIA) as an anticipatory environmental management tool has generated a considerable debate over the extent to which it is achieving its purposes. This has been measured in terms of EIA 'effectiveness', especially as discussion has moved away from issues of procedural implementation, to the more substantive goals of EIA and its place within broader decision-making contexts. Empirical studies have revealed the relatively weak degree of influence on planning decisions that is being exerted by EIA, which is increasingly being attributed to its rationalist beginnings. This article seeks to direct this debate towards themore » founding political purposes of EIA which, it is argued, provide a neglected, yet strong, basis for EIA reform. A number of illustrative suggestions are made as a result of this redirection, to enable EIA to adopt a more determinative role in decision making and to contribute to more sustainable patterns of development planning.« less

  6. Organizational change and environmental impact assessment at the Electricity Generating Authority of Thailand: 1972--1988

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shepherd, A.; Ortolano, L.

    This study examines the influence of leadership, political entrepreneurship, and organizational change on the institutionalization of environmental impact assessment (EIA). The Electricity Generating Authority of Thailand (EGAT) initiated EIA activities earlier and more comprehensively than most developing countries. How and why were EIA activities pursued? Part of the explanation for EGAT`s EIA activities involves external controls exerted by the World Bank, the Thai government, and concerned citizens. However, an explanation based on external factors alone overlooks the significant influence of internal forces and entrepreneurial activities within EGAT. Their analysis of EIA Adoption at EGAT reveals three factors that can contributemore » to the successful implementation of EIA: (1) mutually reinforcing support for EIA from both inside and outside a development agency, (2) political entrepreneurship by agency staff that are concerned about the environment and (3) the transformation of power relationships within the agency by environmental professionals.« less

  7. 77 FR 52708 - Request to Revise a Currently-Approved Data Collection

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-30

    ... Management and Budget (OMB). EIA proposes changes to the data collection requirements for the Forms EIA-861... creation of the Form EIA-861S, ``Annual Electric Power Industry Report (Short).'' All collection instruments are under OMB Control Number 1905-0129. The Form EIA-861 proposal is to modify the survey frame...

  8. 30 CFR 250.227 - What environmental impact analysis (EIA) information must accompany the EP?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... environmental impact analysis (EIA) information must accompany the EP? The following EIA information must... 30 Mineral Resources 2 2011-07-01 2011-07-01 false What environmental impact analysis (EIA) information must accompany the EP? 250.227 Section 250.227 Mineral Resources BUREAU OF OCEAN ENERGY MANAGEMENT...

  9. 78 FR 13656 - Agency Information Collection Extension

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-28

    ... of the Origin of Natural Gas Liquids Production EIA proposes to suspend the Form EIA-23S and collect..., and natural gas liquids reserves. EIA presents annual reserves data in EIA Web reports to meet this... concerning U.S. crude oil, natural gas, and natural gas liquids reserves, and are incorporated into other...

  10. Relevance of cutoff on a 4th generation ELISA performance in the false positive rate during HIV diagnostic in a low HIV prevalence setting.

    PubMed

    Chacón, Lucía; Mateos, María Luisa; Holguín, África

    2017-07-01

    Despite the high specificity of fourth-generation enzyme immunoassays (4th-gen-EIA) for screening during HIV diagnosis, their positive predictive value is low in populations with low HIV prevalence. Thus, screening should be optimized to reduce false positive results. The influence of sample cutoff (S/CO) values by a 4th-gen-EIA with the false positive rate during the routine HIV diagnosis in a low HIV prevalence population was evaluated. A total of 30,201 sera were tested for HIV diagnosis using Abbott Architect ® HIV-Ag/Ab-Combo 4th-gen-EIA at a hospital in Spain during 17 months. Architect S/CO values were recorded, comparing the HIV-1 positive results following Architect interpretation (S/CO≥1) with the final HIV-1 diagnosis by confirmatory tests (line immunoassay, LIA and/or nucleic acid test, NAT). ROC curve was also performed. Among the 30,201 HIV performed tests, 256 (0.85%) were positive according to Architect interpretation (S/CO≥1) but only 229 (0.76%) were definitively HIV-1 positive after LIA and/or NAT. Thus, 27 (10.5%) of 256 samples with S/CO≥1 by Architect were false positive diagnose. The false positive rate decreased when the S/CO ratio increased. All 19 samples with S/CO ≤10 were false positives and all 220 with S/CO>50 true HIV-positives. The optimal S/CO cutoff value provided by ROC curves was 32.7. No false negative results were found. We show that very low S/CO values during HIV-1 screening using Architect can result HIV negative after confirmation by LIA and NAT. The false positive rate is reduced when S/CO increases. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Environmental Impact Assessment in the marine environment: A comparison of legal frameworks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guerra, Flávia, E-mail: f.c.diasguerra@vu.nl; Liga para a Protecção da Natureza, 1500-124 Lisboa; Grilo, Catarina

    Environmental Impact Assessment (EIA) is a well-established practice in most developed countries, even though its application to projects in the marine environment is at a much earlier stage of development. We use the Portuguese example to address marine EIA legislation since its exclusive economic zone (EEZ) is currently the third largest in the European Union and its EIA legislation does not require various offshore activities with potentially negative environmental impacts to undergo EIA before being licensed. This paper aims to determine whether three types of projects implemented within Portuguese maritime zones – artificial reefs using sunken ships, hydrocarbon prospecting andmore » wave-energy generation – would benefit from application of an appropriately designed EIA. We have conducted a structured review of EIA legal provisions from seven other countries, and considered whether a full EIA was required for each project type. Consequently, 12 Environmental Impact Statements (EIS) have been compared to identify patterns of (dis)similarity across countries and project types. Additionally, we identified key descriptors and predicted impacts for each project type referred to in their EIS. The main conclusion is that ultimately all three projects would benefit from mandatory EIA in Portugal. This paper is relevant for countries with large maritime areas and underdeveloped marine EIA legislation, helping improve international policy-making relating to these three types of marine projects. - Highlights: • EIA is not mandatory for some project types developed in Portuguese maritime zones. • Artificial reefs, oil&gas prospecting and wave-energy licensing differ in 8 countries. • EIA should be mandatory in Portugal for artificial reefs and oil&gas prospecting. • However, an AEInc approach is enough for wave-energy projects in Portugal. • Findings could be extended to other EU countries with extensive maritime zones.« less

  12. Diagnostic discordance for hepatitis C virus infection in hemodialysis patients.

    PubMed

    Kalantar-Zadeh, Kamyar; Miller, Loren G; Daar, Eric S

    2005-08-01

    Hepatitis C virus (HCV) infection is associated with an increase in proinflammatory cytokine levels. Similar changes are seen in maintenance hemodialysis patients with malnutrition-inflammation-cachexia syndrome (MICS), which is associated with poor clinical outcomes in this population. We hypothesized that HCV transcription-mediated amplification (TMA), a sensitive qualitative molecular test for HCV RNA, may identify maintenance hemodialysis patients with HCV infection not detected by means of antibody enzyme immunoassay (EIA), particularly in those with MICS. We evaluated HCV status in 314 maintenance hemodialysis patients by using HCV antibody EIA (version 2.0; Abbott Laboratories, Abbott Park, IL) and HCV TMA (Bayer Diagnostics Laboratories, Berkeley, CA). Twenty-five patients (8%) were EIA positive (EIA+)/TMA+; 4 patients (1%), EIA+/TMA negative (TMA-), and 22 patients (7%), EIA-/TMA+. In the 47 TMA+ patients, the sensitivity of EIA for HCV infection was only 53%. TMA+ patients had lower albumin levels and higher tumor necrosis factor alpha and serum glutamic oxaloacetic transaminase levels than TMA- patients. EIA+/TMA+ patients were more likely than EIA-/TMA+ or EIA-/TMA- patients to have hypoalbuminemia and higher iron and transaminase levels. Of all TMA+ patients, EIA- patients were more likely to have diabetes, be on dialysis therapy longer, and have lower liver enzyme levels and higher proinflammatory cytokine levels, including tumor necrosis factor alpha and interleukin 6. Maintenance hemodialysis patients infected with HCV according to TMA have clinical features suggestive of MICS. In this population, HCV EIA appears to have a low sensitivity for the identification of HCV infection, which may be caused by the confounding effect of MICS or other demographic or clinical factors. These apparently false-negative HCV antibody test results are seen in persons with a longer time on hemodialysis therapy, mirroring observations in other populations with serious progressive conditions, such as human immunodeficiency virus infection.

  13. Evaluation of Sanofi Diagnostics Pasteur Chlamydia Microplate EIA shortened assay and comparison with cell culture and Syva Chlamydia MicroTrak II EIA in high- and low-risk populations.

    PubMed

    Chan, E L; Brandt, K; Horsman, G

    1995-11-01

    Seven hundred thirty-two female urogenital samples were collected for Chlamydia trachomatis testing by both the Sanofi Diagnostics Pasteur (Chaska, Minn.) Chlamydia Microplate EIA by the shortened protocol and the Syva (San Jose, Calif.) MicroTrak II EIA, and the results were compared with those obtained by cell culture. For the analysis of samples from female patients, the patients were divided into high- and low-risk categories. An additional 121 male urethral samples were collected and tested by the Sanofi Microplate EIA and cell culture; for the analysis of samples from male patients, the patients were divided into asymptomatic and symptomatic categories. All specimens positive by enzyme immunoassay (EIA) were confirmed by a blocking assay following the respective manufacturer's instructions. Specimens negative by EIA that fell within a gray zone 30% below the cutoff and negative cultures with one or more corresponding positive EIA results were tested further by cytocentrifugation and direct immunofluorescent assay. The overall sensitivity, specificity, positive predictive value, and negative predictive value for Syva versus culture were 94, 98.8, 85.5 and 99.6%, respectively. After resolution, the results were 94.5, 99.6, 94.5, and 99.6%, respectively. The parallel results for the Sanofi Microplate EIA versus culture were 94.0, 98.7, and 83.9, and 99.6%, respectively, and after being resolved, the results were 94.9, 100, 100, and 99.6%, respectively. In the small male population tested, the resolved results of the Sanofi Microplate EIA versus culture demonstrated sensitivity, specificity, positive predictive value, and negative predictive value of 100, 100, 100, and 100%, respectively. The present study demonstrated that the Sanofi Microplate EIA shortened protocol is highly sensitive and specific in comparison with cell culture and the Syva MicroTrak II EIA.

  14. Characterizing monoclonal antibody structure by carboxyl group footprinting

    PubMed Central

    Kaur, Parminder; Tomechko, Sara E; Kiselar, Janna; Shi, Wuxian; Deperalta, Galahad; Wecksler, Aaron T; Gokulrangan, Giridharan; Ling, Victor; Chance, Mark R

    2015-01-01

    Structural characterization of proteins and their antigen complexes is essential to the development of new biologic-based medicines. Amino acid-specific covalent labeling (CL) is well suited to probe such structures, especially for cases that are difficult to examine by alternative means due to size, complexity, or instability. We present here a detailed account of carboxyl group labeling (with glycine ethyl ester (GEE) tagging) applied to a glycosylated monoclonal antibody therapeutic (mAb). The experiments were optimized to preserve the structural integrity of the mAb, and experimental conditions were varied and replicated to establish the reproducibility of the technique. Homology-based models were generated and used to compare the solvent accessibility of the labeled residues, which include aspartic acid (D), glutamic acid (E), and the C-terminus (i.e., the target probes), with the experimental data in order to understand the accuracy of the approach. Data from the mAb were compared to reactivity measures of several model peptides to explain observed variations in reactivity. Attenuation of reactivity in otherwise solvent accessible probes is documented as arising from the effects of positive charge or bond formation between adjacent amine and carboxyl groups, the latter accompanied by observed water loss. A comparison of results with previously published data by Deperalta et al using hydroxyl radical footprinting showed that 55% (32/58) of target residues were GEE labeled in this study whereas the previous study reported 21% of the targets were labeled. Although the number of target residues in GEE labeling is fewer, the two approaches provide complementary information. The results highlight advantages of this approach, such as the ease of use at the bench top, the linearity of the dose response plots at high levels of labeling, reproducibility of replicate experiments (<2% variation in modification extent), the similar reactivity of the three target probes, and significant correlation of reactivity and solvent accessible surface area. PMID:25933350

  15. High-Throughput Epitope Binning Assays on Label-Free Array-Based Biosensors Can Yield Exquisite Epitope Discrimination That Facilitates the Selection of Monoclonal Antibodies with Functional Activity

    PubMed Central

    Abdiche, Yasmina Noubia; Miles, Adam; Eckman, Josh; Foletti, Davide; Van Blarcom, Thomas J.; Yeung, Yik Andy; Pons, Jaume; Rajpal, Arvind

    2014-01-01

    Here, we demonstrate how array-based label-free biosensors can be applied to the multiplexed interaction analysis of large panels of analyte/ligand pairs, such as the epitope binning of monoclonal antibodies (mAbs). In this application, the larger the number of mAbs that are analyzed for cross-blocking in a pairwise and combinatorial manner against their specific antigen, the higher the probability of discriminating their epitopes. Since cross-blocking of two mAbs is necessary but not sufficient for them to bind an identical epitope, high-resolution epitope binning analysis determined by high-throughput experiments can enable the identification of mAbs with similar but unique epitopes. We demonstrate that a mAb's epitope and functional activity are correlated, thereby strengthening the relevance of epitope binning data to the discovery of therapeutic mAbs. We evaluated two state-of-the-art label-free biosensors that enable the parallel analysis of 96 unique analyte/ligand interactions and nearly ten thousand total interactions per unattended run. The IBIS-MX96 is a microarray-based surface plasmon resonance imager (SPRi) integrated with continuous flow microspotting technology whereas the Octet-HTX is equipped with disposable fiber optic sensors that use biolayer interferometry (BLI) detection. We compared their throughput, versatility, ease of sample preparation, and sample consumption in the context of epitope binning assays. We conclude that the main advantages of the SPRi technology are its exceptionally low sample consumption, facile sample preparation, and unparalleled unattended throughput. In contrast, the BLI technology is highly flexible because it allows for the simultaneous interaction analysis of 96 independent analyte/ligand pairs, ad hoc sensor replacement and on-line reloading of an analyte- or ligand-array. Thus, the complementary use of these two platforms can expedite applications that are relevant to the discovery of therapeutic mAbs, depending upon the sample availability, and the number and diversity of the interactions being studied. PMID:24651868

  16. Development and validation of a sensitive and fast chemiluminescent enzyme immunoassay for the detection of genetically modified maize.

    PubMed

    Roda, A; Mirasoli, M; Guardigli, M; Michelini, E; Simoni, P; Magliulo, M

    2006-03-01

    Proteins from the Cry 1 family, in particular Cry 1Ab, are commonly expressed in genetically modified Bt maize in order to control chewing insect pests. A sensitive chemiluminescent sandwich enzyme immunoassay for the detection of Cry1Ab protein from genetically modified Bt maize has been developed and validated. A Cry1Ab protein-specific antibody was immobilized on 96- or 384-well microtiter plates in order to capture the Cry1Ab toxin in the sample; the bound toxin was then detected by employing a second anti-Cry1Ab antibody and a horseradish peroxidase-labeled anti-antibody, followed by measurement of the enzyme activity with an enhanced chemiluminescent system. The chemiluminescent assay fulfilled all the requirements of accuracy and precision and exhibited limits of detection of a few pg mL(-1) Cry1Ab (3 or 5 pg mL(-1), depending on the assay format), which are significantly lower than that achievable using conventional colorimetric detection of peroxidase activity and also represent an improvement compared to previously developed Cry1Ab immunoassays. High-throughput analysis can be performed using the 384-well microtiter plate format immunoassay, which also allows one to reduce the consumption of samples and reagents. Validation of the assay, performed by analyzing certified reference materials, proved that the immunoassay is able to detect the presence of the Cry1Ab protein in certified reference samples containing as low as 0.1% of MON 810 genetically modified Bt maize. This value is below the threshold requiring mandatory labeling of foods containing genetically modified material according to the actual EU regulation.

  17. 30 CFR 250.261 - What environmental impact analysis (EIA) information must accompany the DPP or DOCD?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... analysis (EIA) information must accompany the DPP or DOCD? The following EIA information must accompany... 30 Mineral Resources 2 2011-07-01 2011-07-01 false What environmental impact analysis (EIA) information must accompany the DPP or DOCD? 250.261 Section 250.261 Mineral Resources BUREAU OF OCEAN ENERGY...

  18. Wind and Solar Data Projections from the U.S. Energy Information Administration: Past Performance and Planned Enhancements

    EIA Publications

    2016-01-01

    In an effort to improve EIA's approach to providing accurate, comprehensive data, and useful projections for policy analysis, EIA has conducted a review of its historical data and projections of capacity, generation, and cost projections for wind and solar technologies. While EIA's internal processes and engagement with stakeholders are both continuing, this paper shares some early findings of EIA's current review of our wind and solar data and projections, focusing in part on some of the issues that have been publicly raised by EIA's critics.

  19. Immunophenotype of leukemic blasts with small peroxidase-positive granules detected by electron microscopy.

    PubMed

    Vainchenker, W; Villeval, J L; Tabilio, A; Matamis, H; Karianakis, G; Guichard, J; Henri, A; Vernant, J P; Rochant, H; Breton-Gorius, J

    1988-05-01

    Forty-three cases of undifferentiated leukemias by light microscopy examination were diagnosed as acute myeloblastic leukemias by ultrastructural revelation of peroxidase and were subsequently studied by immunological markers. In 41 of these cases, blasts were labeled by at least one of the antimyeloid MoAbs (My 7, My 9, and 80H5). An antimyeloperoxidase polyclonal antibody was used in 23 cases and was clearly positive in 11 of them, while cytochemistry by light microscopy was negative. These myeloblasts were frequently mixed with a minority of blasts from other lineages especially promegakaryoblasts. It is noteworthy that in 6 cases myeloid and lymphoid markers (E rosette receptor, common acute lymphoblastic leukemia antigen (cALLA), CD 9, CD 19 antigens (anti-B4 MoAb] were detected on a fraction of blast cells, suggesting a bilineage leukemia. However, in double labeling experiments, blasts with myeloperoxidase coexpressed lymphoid and myeloid markers including cALLA and CD 19 antigen. In one case, blasts had a typical non-B, non-T acute lymphoblastic leukemia phenotype (HLA-DR, CD 9, CD 19, cALLA positive) without staining by any of the antimyeloid MoAbs. However, 70% of the blasts were labeled by the antimyeloperoxidase antibody and expressed peroxidase-positive granules at ultrastructural level. In conclusion, most of the AML undiagnosed by optical cytochemistry are identified by antimyeloid antibodies. Some of these cases are also stained by some antilymphoid MoAbs. Use of antibodies against myeloperoxidase may improve the diagnosis of difficult cases of acute myeloblastic leukemia.

  20. Implications of recent EIA changes in Thailand

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tongcumpou, C.; Harvey, N.

    The practice of environmental impact assessment (EIA) was implemented in Thailand after the revision of the National Environmental Quality Act in 1978. This led to more than 3,000 EIA documents being prepared and officially submitted up to 1992. More recently, a new act, the Enhancement and Conservation of National Environmental Quality Act, was introduced in 1992. As a consequence, some aspects of environmental legislation have been improved including the EIA process, which is expected to be more effective under the new act. This article examines the development and implementation of the EIA process in Thailand and its effectiveness in themore » context of its performance as an environmental management tool. The strengths and weaknesses of the EIA process under the original act are analyzed and compared to the new act, using two case studies in order to gain an insight into the EIA system. The first is the Second Stage Expressway in Bangkok, and the second is the Pak Mun Hydroelectric Dam project in Ubon Rachathani, a northeastern province of Thailand. EIAs for these projects were originally submitted according to the requirements of the old act. Both are public projects that have aroused controversy for different environmental reasons, although final decisions have been made facilitating the implementation of these projects. Finally, the article presents some suggestions for improving the content and procedures for the EIA system in Thailand.« less

  1. 31 CFR 26.3 - Availability of Environmental Impact Assessment Summaries (EIA Summaries) and Environmental...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 31 Money and Finance: Treasury 1 2010-07-01 2010-07-01 false Availability of Environmental Impact Assessment Summaries (EIA Summaries) and Environmental Impact Assessments (EIAs). 26.3 Section 26.3 Money and...) 466-8191, not a toll-free call). (ii) If a copy of an EIA Summary is not available from the BIC...

  2. 31 CFR 26.3 - Availability of Environmental Impact Assessment Summaries (EIA Summaries) and Environmental...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 31 Money and Finance: Treasury 1 2012-07-01 2012-07-01 false Availability of Environmental Impact Assessment Summaries (EIA Summaries) and Environmental Impact Assessments (EIAs). 26.3 Section 26.3 Money and...) 466-8191, not a toll-free call). (ii) If a copy of an EIA Summary is not available from the BIC...

  3. 31 CFR 26.3 - Availability of Environmental Impact Assessment Summaries (EIA Summaries) and Environmental...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 31 Money and Finance: Treasury 1 2014-07-01 2014-07-01 false Availability of Environmental Impact Assessment Summaries (EIA Summaries) and Environmental Impact Assessments (EIAs). 26.3 Section 26.3 Money and...) 466-8191, not a toll-free call). (ii) If a copy of an EIA Summary is not available from the BIC...

  4. 31 CFR 26.3 - Availability of Environmental Impact Assessment Summaries (EIA Summaries) and Environmental...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 31 Money and Finance: Treasury 1 2011-07-01 2011-07-01 false Availability of Environmental Impact Assessment Summaries (EIA Summaries) and Environmental Impact Assessments (EIAs). 26.3 Section 26.3 Money and...) 466-8191, not a toll-free call). (ii) If a copy of an EIA Summary is not available from the BIC...

  5. 31 CFR 26.3 - Availability of Environmental Impact Assessment Summaries (EIA Summaries) and Environmental...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 31 Money and Finance: Treasury 1 2013-07-01 2013-07-01 false Availability of Environmental Impact Assessment Summaries (EIA Summaries) and Environmental Impact Assessments (EIAs). 26.3 Section 26.3 Money and...) 466-8191, not a toll-free call). (ii) If a copy of an EIA Summary is not available from the BIC...

  6. Ecological compensation and Environmental Impact Assessment in Spain

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Villarroya, Ana, E-mail: avillarroya@alumni.unav.e; Puig, Jordi, E-mail: jpbaguer@unav.e

    2010-11-15

    To achieve meaningful sustainable development, Environmental Impact Assessment (EIA) should avoid the net losses in the environment resource base. But EIA practice does not always avoid the losses caused by the implementation of the projects under EIA regulation. Some environmental impacts are, simply, admitted, even without enforcing any form of compensation. When applied, compensation is sometimes just a monetary payment to offset the environmental loss. This paper looks for evidence on the role that compensation is given at present in EIA practice in Spain, and for some of its conceptual and regulatory roots. Specifically, it explores how compensation is addressedmore » in 1302 records of decision (RODs) on those projects subject to the Spanish EIA regulation published during the years 2006 and 2007, to know how far Spain is from preserving the environmental resource base managed through this particular aspect of EIA practice. As a result, it is concluded that the practice of ecological compensation in EIA in Spain is much lower than it could be expected in a theoretical sustainability context committed to avoid net losses in the environment resource base, mainly due to an EIA practice focused on on-site mitigation that allows these net losses.« less

  7. False-positive buprenorphine EIA urine toxicology results due to high dose morphine: a case report.

    PubMed

    Tenore, Peter L

    2012-01-01

    In monitoring a patient with chronic pain who was taking high-dose morphine and oxycodone with weekly urine enzymatic immunoassay (EIA) toxicology testing, the authors noted consistent positives for buprenorphine. The patient was not taking buprenorphine, and gas chromatography/mass spectroscopy (GCMS) testing on multiple samples revealed no buprenorphine, indicating a case of false-positive buprenorphine EIAs in a high-dose opiate case. The authors discontinued oxycodone for a period of time and then discontinued morphine. Urine monitoring with EIAs and GCMS revealed false-positive buprenorphine EIAs, which remained only when the patient was taking morphine. When taking only oxycodone and no morphine, urine samples became buprenorphine negative. When morphine was reintroduced, false-positive buprenorphine results resumed. Medical practitioners should be aware that high-dose morphine (with morphine urine levels turning positive within the 15,000 to 28,000 mg/mL range) may produce false-positive buprenorphine EIAs with standard urine EIA toxicology testing.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ngunjiri, P.G.

    The aim for this research is to review environmental impact assessment (EIA) practices in sub-Saharan Africa, drawing upon appropriate theoretical and methodological work on EIA. This study uses a comparative evaluation method to examine the extent of environmental impact assessment (EIA) in project analysis. It uses site and services low cost housing projects from Kenya. The research has three major components: (1) review of environmental practice in Sub-Saharan Africa through literature review and case studies; (2) review of general literature on EIA as practiced by international agencies and developed countries; and (3) formulation of more suitable guidelines for EIA proceduresmore » in Sub-Saharan Africa.« less

  9. How EIA Estimates Natural Gas Production

    EIA Publications

    2004-01-01

    The Energy Information Administration (EIA) publishes estimates monthly and annually of the production of natural gas in the United States. The estimates are based on data EIA collects from gas producing states and data collected by the U. S. Minerals Management Service (MMS) in the Department of Interior. The states and MMS collect this information from producers of natural gas for various reasons, most often for revenue purposes. Because the information is not sufficiently complete or timely for inclusion in EIA's Natural Gas Monthly (NGM), EIA has developed estimation methodologies to generate monthly production estimates that are described in this document.

  10. A quantitative method to analyze the quality of EIA information in wind energy development and avian/bat assessments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chang, Tony, E-mail: tc282@nau.edu; Nielsen, Erik, E-mail: erik.nielsen@nau.edu; Auberle, William, E-mail: william.auberle@nau.edu

    2013-01-15

    The environmental impact assessment (EIA) has been a tool for decision makers since the enactment of the National Environmental Policy Act (NEPA). Since that time, few analyses have been performed to verify the quality of information and content within EIAs. High quality information within assessments is vital in order for decision makers, stake holders, and the public to understand the potential impact of proposed actions on the ecosystem and wildlife species. Low quality information has been a major cause for litigation and economic loss. Since 1999, wind energy development has seen an exponential growth with unknown levels of impact onmore » wildlife species, in particular bird and bat species. The purpose of this article is to: (1) develop, validate, and apply a quantitative index to review avian/bat assessment quality for wind energy EIAs; and (2) assess the trends and status of avian/bat assessment quality in a sample of wind energy EIAs. This research presents the development and testing of the Avian and Bat Assessment Quality Index (ABAQI), a new approach to quantify information quality of ecological assessments within wind energy development EIAs in relation to avian and bat species based on review areas and factors derived from 23 state wind/wildlife siting guidance documents. The ABAQI was tested through a review of 49 publicly available EIA documents and validated by identifying high variation in avian and bat assessments quality for wind energy developments. Of all the reviewed EIAs, 66% failed to provide high levels of preconstruction avian and bat survey information, compared to recommended factors from state guidelines. This suggests the need for greater consistency from recommended guidelines by state, and mandatory compliance by EIA preparers to avoid possible habitat and species loss, wind energy development shut down, and future lawsuits. - Highlights: Black-Right-Pointing-Pointer We developed, validated, and applied a quantitative index to review avian/bat assessment quality for wind energy EIAs. Black-Right-Pointing-Pointer We assessed the trends and status of avian/bat assessment quality in a sample of wind energy EIAs. Black-Right-Pointing-Pointer Applied index to 49 EIA documents and identified high variation in assessment quality for wind energy developments. Black-Right-Pointing-Pointer For the reviewed EIAs, 66% provided inadequate preconstruction avian and bat survey information.« less

  11. Horseradish peroxidase functionalized gold nanorods as a label for sensitive electrochemical detection of alpha-fetoprotein antigen.

    PubMed

    Guo, Jinjin; Han, Xiaowei; Wang, Junchun; Zhao, Junqing; Guo, Zilin; Zhang, Yuzhong

    2015-12-15

    In this study, a novel tracer, horseradish peroxidase (HRP) functionalized gold nanorods (Au NRs) nanocomposites (HRP-Au NRs), was designed to label the signal antibodies for sensitive electrochemical measurement of alpha-fetoprotein (AFP). The preparation of HRP-Au NRs nanocomposites and the labeling of secondary antibody (Ab2) were performed by one-pot assembly of HRP and Ab2 on the surface of Au NRs. The immunosensor was fabricated by assembling carbon nanotubes (CNTs), Au NRs, and capture antibodies (Ab1) on the glassy carbon electrode. In the presence of AFP antigen, the labels were captured on the surface of the Au NRs/CNTs via specific recognition of antigen-antibody, resulting in the signal intensity being clearly increased. Differential pulse voltammetry (DPV) was employed to record the response signal of the immunosensor in phosphate-buffered saline (PBS) containing hydrogen peroxide (H2O2) and 3,3',5,5'-tetramethylbenzidine (TMB). Under optimal conditions, the signal intensity was linearly related to the concentration of AFP in the range of 0.1-100 ng ml(-1), and the limit of detection was 30 pg ml(-1) (at signal/noise [S/N] = 3). Furthermore, the immunoassay method was evaluated using human serum samples, and the recovery obtained was within 99.0 and 102.7%, indicating that the immunosensor has potential clinical applications. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. Clinical application of polymerase chain reaction to diagnose Clostridium difficile in hospitalized patients with diarrhea.

    PubMed

    Morelli, Michael S; Rouster, Susan D; Giannella, Ralph A; Sherman, Kenneth E

    2004-08-01

    Clostridium difficile is a common cause of diarrhea in hospitalized patients and is associated with significant morbidity and cost. The current diagnostic standard, enzyme immunoassay (EIA), has low sensitivity, leading to duplicate testing and empiric treatment. We sought to show the usefulness and potential cost effectiveness of polymerase chain reaction (PCR) amplification of toxin B gene for diagnosis of C. difficile-induced diarrhea. A total of 148 stool samples from academic and community-based hospitals were sent for EIA testing and were evaluated prospectively for the presence of toxin B gene by PCR. Results were compared with EIA regarding sensitivity, specificity, and predictive values. Medical charts were reviewed to determine the following: (1) number of EIAs sent per admission, (2) number sent within a 24-hour time period, and (3) how caregivers practiced based on EIA results. The mean age of 130 patients was 55 years. EIA and PCR were positive in 6.8% and 13.6% of patients, respectively. EIA sensitivity was 40%, specificity was 98%, and positive and negative predictive values were 80% and 91%, respectively. The cost of the PCR was $22/sample. Empiric treatment for C. difficile was given unnecessarily in 42% of EIA-negative results. Thirty percent of patients had 3 or more EIAs sent during their hospital admission. Of patients with multiple samples sent, 57% had more than 1 sample sent in a 24-hour period. Many physicians do not conform to practice guidelines regarding recommended diagnosis and empiric treatment of C. difficile. Toxin B gene PCR represents a more sensitive and potentially cost-effective method to diagnose C. difficile-induced diarrhea than EIA and should be considered for use as an alternative diagnostic standard.

  13. Evaluation of an enzyme immunoassay system for measuring herpes simplex virus (HSV) type 1-specific and HSV type 2-specific IgG antibodies.

    PubMed

    Prince, H E; Ernst, C E; Hogrefe, W R

    2000-01-01

    MRL Diagnostics has developed a dual enzyme immunoassay (EIA) system that employs the recombinant Herpes Simplex Virus (HSV) type-specific glycoproteins G1 (HSV1) and G2 (HSV2) to detect HSV type-specific IgG antibodies. This system was evaluated using 155 consecutive sera previously tested in a conventional dual EIA system (Zeus) that employs multiple HSV1 and HSV2 proteins to detect type-common as well as type-specific antibodies. Sera were also analyzed by Western blot to determine the true HSV type-specific IgG reactivity pattern. Of 110 sera giving concordant reactivity patterns in the MRL and Zeus EIA systems, 108 (98%) also displayed concordant Western blot patterns; two sera gave false positive HSV2 reactivity in both EIA systems. Of 45 sera giving discordant MRL and Zeus EIA reactivity patterns, 41 (91%) displayed a Western blot reactivity pattern that matched the MRL reactivity pattern. Both the HSV1 IgG component and the HSV2 IgG component of the MRL EIA system were 100% sensitive and > 95% specific. In contrast, the Zeus HSV1 IgG EIA was 98% sensitive and 79% specific, and the Zeus HSV2 IgG EIA was 85% sensitive and 79% specific. An analysis of the distribution of index values in the MRL EIA system showed that low-positive values (1.0-3.0) were rare, but, when detected, often represented false positive results; only 11 MRL low-positive results were observed, but all 6 MRL false positive results were found within this low-positive subgroup. These findings show that the MRL dual EIA system effectively detects HSV type-specific IgG antibodies. Copyright 2000 Wiley-Liss, Inc.

  14. Evaluation of bioMérieux's Dissociated Vidas Lyme IgM II and IgG II as a First-Tier Diagnostic Assay for Lyme Disease

    PubMed Central

    Delorey, Mark J.; Replogle, Adam; Sexton, Christopher; Schriefer, Martin E.

    2017-01-01

    ABSTRACT The recommended laboratory diagnostic approach for Lyme disease is a standard two-tiered testing (STTT) algorithm where the first tier is typically an enzyme immunoassay (EIA) that if positive or equivocal is reflexed to Western immunoblotting as the second tier. bioMérieux manufactures one of the most commonly used first-tier EIAs in the United States, the combined IgM/IgG Vidas test (LYT). Recently, bioMérieux launched its dissociated first-tier tests, the Vidas Lyme IgM II (LYM) and IgG II (LYG) EIAs, which use purified recombinant test antigens and a different algorithm than STTT. The dissociated LYM/LYG EIAs were evaluated against the combined LYT EIA using samples from 471 well-characterized Lyme patients and controls. Statistical analyses were conducted to assess the performance of these EIAs as first-tier tests and when used in two-tiered algorithms, including a modified two-tiered testing (MTTT) approach where the second-tier test was a C6 EIA. Similar sensitivities and specificities were obtained for the two testing strategies (LYT versus LYM/LYG) when used as first-tier tests (sensitivity, 83 to 85%; specificity, 85 to 88%) with an observed agreement of 80%. Sensitivities of 68 to 69% and 76 to 77% and specificities of 97% and 98 to 99% resulted when the two EIA strategies were followed by Western immunoblotting and when used in an MTTT, respectively. The MTTT approach resulted in significantly higher sensitivities than did STTT. Overall, the LYM/LYG EIAs performed equivalently to the LYT EIA in test-to-test comparisons or as first-tier assays in STTT or MTTT with few exceptions. PMID:28330884

  15. [GM1-dot-EIA for the detection of toxin-producing Vibrio cholerae strains].

    PubMed

    Markina, O V; Alekseeva, L P; Telesmanich, N R; Chemisova, O S; Akulova, M V; Markin, N V

    2011-05-01

    A new variant of enzyme immunoassay (EIA) has been developed on the basis of GM1 gangliosides to detect the toxin-producing Vibrio cholerae strains--GM1-dot-EIA. Experiments were run using a nitrocellulose membrane to bind GM1 gangliosides and polyclonal antitoxic serum to detect cholerogen. GM1-dot-EIA testing identified cholera toxin in 11 of 13 supernatants of V. cholerae eltor ctx(+) strains isolated from man and in 3 of 7 supernatants of V. cholerae eltor ctx(+) strains isolated from water. These data agree with those obtained in CM1-EIA. There was no reaction with the supernatants of other microorganisms. The sensitivity of the technique was 10 ng/ml. Thus, the simple and specific GM1-dot-EIA may be recommended to detect toxin-producing V cholerae strains isolated from man and water.

  16. Practitioner perspectives on the role of science in environmental impact assessment.

    PubMed

    Morrison-Saunders, Angus; Bailey, John

    2003-06-01

    A large body of literature addresses the role of science in environmental impact assessment (EIA) but less attention has been given to the views of practitioners themselves. In this research a survey of 31 EIA practitioners in Western Australia was undertaken to determine their perceptions of the quality and importance of science in EIA. The survey results are compared with previous theoretical, empirical, and survey studies of the role of science in EIA. Interview questions addressed the role of science in impact prediction, monitoring activities, mitigation and management, and EIA decision-making. It was clear from the interviews that many practitioners are satisfied with the quality of science currently used in EIA, but do not believe that it is given sufficient importance in the process. The quality and importance of science in the predecision stages of EIA was rated higher than in the postdecision stages. While science was perceived to provide the basis for baseline data collection, impact prediction, and mitigation design, it was seen to be less important during decision-making and ongoing project management. Science was seen to be just one input to decision-makers along with other factors such as sociopolitical and economic considerations. While time and budget constraints were seen to limit the scientific integrity of EIA activities, pressure from the public and regulatory authorities increased it. Improving the scientific component of EIA will require consideration of all these factors, not just the technical issues.

  17. Use of Animal Species Data in Environmental Impact Assessments

    NASA Astrophysics Data System (ADS)

    Knegtering, Edo; Drees, J. Marijke; Geertsema, Paul; Huitema, Hans J.; Uiterkamp, Anton J. M. Schoot

    2005-12-01

    Environmental Impact Assessments (EIAs) should ideally help minimize adverse effects on biological diversity by considering impacts of projects on wide ranges of species. This paper investigates how recent Dutch EIAs included the species comprising animal diversity. We present results of two studies on fauna data used in the EIAs. Objectives were to determine for different taxa (a) the relative representation of species in Environmental Impact Statements (EISs); (b) the extent to which EISs referred to specific species and the accuracy of survey data referred to; and (c) apparent roles of different EIA actors in species inclusion. EIAs were found to use data on various taxa but on limited numbers of species. The frequency with which taxa were included varied significantly. Birds were most frequently included, followed by mammals, amphibians, and other species groups. The quality of data on birds exceeded that regarding other vertebrates. Our results indicate that (a) EIA working groups of independent experts were the most influential in determining the data to be used; (b) on average, proponents included data more often than required by guidelines; and (c) in 30 to 40% of the EIAs, the participation of nongovernmental organizations prompted use of data. Despite the key role of experts in data inclusion, the taxon rankings found in the EIAs showed little deviation from those observed in studies on people’s preferences for species. Given the limited ranges of species considered, it is doubtful that the EIAs examined effectively contributed to conserving animal species diversity.

  18. Detection of Total Ergot Alkaloids in Cereal Flour and in Bread by a Generic Enzyme Immunoassay Method.

    PubMed

    Gross, Madeleine; Curtui, Valeriu; Usleber, Ewald

    2018-05-01

    Four sets of polyclonal antibodies against ergot alkaloids ergometrine, ergotamine, α-ergocryptine, and ergocornine were produced and characterized in a competitive direct or indirect enzyme immunoassay (EIA). Standard curve LODs were 0.03 ng/mL (ergometrine EIA) to 2.0 ng/mL (ergocornine EIA). Three EIAs were highly specific, whereas the ergometrine EIA had a broad specificity pattern and reacted, albeit weakly, with all seven major ergot alkaloids and their epimeric forms. Using the ergometrine EIA, a generic test system was established in which total ergot alkaloids are quantified by a standard curve for a toxin mixture composed of three alkaloids that matched the ergot alkaloid composition in naturally contaminated rye and wheat products. Sample extraction with acetonitrile-phosphate-buffered saline at pH 6.0 without further cleanup was sufficient for EIA analysis. The LODs for total ergot alkaloids were 20 ng/g in rye and wheat flour and 14 ng/g in bread. Recoveries were 85-110% (RSDs of 0.1-11.7%) at a concentration range of 50-1000 ng/g. The total ergot alkaloid EIA was validated by comparison with HPLC-fluorescence detection. Although some under- and overestimation by the total ergot alkaloid EIA was observed, it was suitable for the reliable identification of positive samples at 10-20 ng/g and for the determination of total ergot alkaloids in a concentration range between 100 and 1000 ng/g.

  19. The strength and hemispheric asymmetry of Equatorial Ionization Anomaly during two geomagnetic storms in 2013 from Global Ionosphere Map and SAMI2

    NASA Astrophysics Data System (ADS)

    Luo, Weihua; Zhu, Zhengping; Lan, Jiaping

    2016-08-01

    The variations of the strength and the hemispheric asymmetry of EIA were studied by Global Ionosphere Map (GIM) and SAMI2 during two geomagnetic storm periods in March and June 2013. Compared with the 30-days median TEC, the TEC at the two crests of EIA had small variations while the TEC at the trough had a more remarkable variation for the two storms after the SSC. The TEC difference between the two EIA peaks had an increase or decrease several hours after the SSC, the asymmetry between the two crests of EIA represented by the defined asymmetry index has no obvious variations except several hours after the SSC, and EIA strength represented by the Crest-to-Trough Ratio (CTR) had a remarkable increase one day after the SSC day for March storm and decrease several hours after the SSC for June storm. The variations last several hours, with more than 40% variations compared with the value during the quiet period. The EIA peaks were also found to move toward the equator after the SSC during the two storms. The simulation from SAMI2 and HWM07 also shows that EIA crests would move toward the equator during storm time and EIA strength would decrease, which suggests that the disturbed neutral wind and disturbed electric field may be important factors affecting the EIA during the storm periods.

  20. Public participation in environmental impact assessment: why, who and how?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Glucker, Anne N., E-mail: anne.glucker@gmx.de; Driessen, Peter P.J., E-mail: p.driessen@uu.nl; Kolhoff, Arend, E-mail: akolhoff@eia.nl

    2013-11-15

    Even a cursory glance at the literature on environmental impact assessment (EIA) reveals that public participation is being considered as an integral part of the assessment procedure. Public participation in EIA is commonly deemed to foster democratic policy-making and to render EIA more effective. Yet a closer look at the literature unveils that, beyond this general assertion, opinions of the precise meaning, objectives and adequate representation of public participation in EIA considerably diverge. Against this background, in this article we aim to provide a comprehensive overview of the academic debate on public participation in EIA concerning its meaning, objectives andmore » adequate level of inclusiveness. In so doing, we hope to stimulate a more focused debate on the subject, which is key to advancing the research agenda. Furthermore, this paper may serve as a starting point for practitioners involved in defining the role of public participation in EIA practice. -- Highlights: • There is little reflection on the meaning, objectives and adequate level of inclusiveness of public participation in EIA. • We provide a comprehensive overview of the academic debate on public participation in EIA concerning the meaning, objectives and adequate level of inclusiveness. • Theoretical claims put forth by scholars are contrasted with empirical evidence. • Overview shall stimulate a more focused debate on the subject. • This paper may serve as a starting point for practitioners involved in defining the role of public participation in EIA.« less

  1. Nanostructures based on quantum dots for application in promising methods of single- and multiphoton imaging and diagnostics

    NASA Astrophysics Data System (ADS)

    Nabiev, I. R.

    2017-01-01

    Molecules recognizing biomarkers of diseases (monoclonal antibodies (monoABs)) are often too large for biomedical applications, and the conditions that are used to bind them with nanolabels lead to disordered orientation of monoABs with respect to the nanoparticle surface. Extremely small nanoprobes, designed via oriented conjugation of quantum dots (QDs) with single-domain antibodies (sdABs) derived from the immunoglobulin of llama and produced in the E. coli culture, have a hydrodynamic diameter less than 12 nm and contain equally oriented sdAB molecules on the surface of each QD. These nanoprobes exhibit excellent specificity and sensitivity in quantitative determination of a small number of cells expressing biomarkers. In addition, the higher diffusion coefficient of sdABs makes it possible to perform immunohistochemical analysis in bulk tissue, inaccessible for conventional monoABs. The necessary conditions for implementing high-quality immunofluorescence diagnostics are a high specificity of labeling and clear differences between the fluorescence of nanoprobes and the autofluorescence of tissues. Multiphoton micros-copy with excitation in the near-IR spectral range, which is remote from the range of tissue autofluorescence excitation, makes it possible to solve this problem and image deep layers in biological tissues. The two-photon absorption cross sections of CdSe/ZnS QDs conjugated with sdABs exceed the corresponding values for organic fluorophores by several orders of magnitude. These nanoprobes provide clear discrimination between the regions of tumor and normal tissues with a ratio of the sdAB fluorescence to the tissue autofluorescence upon two-photon excitation exceeding that in the case of single-photon excitation by a factor of more than 40. The data obtained indicate that the sdAB-QD conjugates used as labels provide the same, or even better, quality as the "gold standard" of immunohistochemical diagnostics. The developed nanoprobes are expected to find wide application in high-efficiency imaging of tumor and multiparameter diagnostics.

  2. [Inhibitory effect of ¹³¹I-CD133mAb combined with cisplatin on liver cancer cells in vitro and in a tumor-bearing mouse model].

    PubMed

    Chen, Xingyue; Hou, Yanli; Duan, Liqun; Tang, Min; Kang, Qiangqiang; Shu, Jin; Peng, Zhiping; Li, Shaolin

    2014-06-01

    To study the inhibitory effect of CD133 monoclonal antibody labeled with ¹³¹I (¹³¹I-CD133mAb) on Huh-7 human liver cancer cell line overexpressing CD133 antigen in vitro and in mouse models bearing the tumor cell xenograft. ¹³¹I-CD133mAb was prepared by chloramines-T method and evaluated for its stability. Flow cytometry and immunohistochemistry were used to detect the expression of CD133 in Huh-7 cells and in Huh-7 cell-derived tumors, respectively. Huh-7 cells treated with ¹³¹I-CD133mAb plus cisplatin (DDP), ¹³¹I -CD133mAb, DDP, or no treatment (blank control) were examined for cell proliferation suppression by MTT assay with the IC₅₀ calculated. BALB/c mice bearing subcutaneous Huh-7 cell xenograft in the right forelegs were treated with ¹³¹I -CD133mAb, DDP, or both every two days for two weeks. The tumor size and volume were measured twice a week, and pathological examination of the tumor was carried out after the treatments. The tumor inhibition rate was calculated and tumor cell apoptosis observed with HE staining. The labeling ratio of ¹³¹I-CD133mAb was 90.25% and the radiochemical purity was 97.78%. Huh-7 cells showed obviously higher CD133 expression than HepG2 cells. ¹³¹I-CD133mAb combined with DDP group resulted in a significantly higher tumor inhibition rate than other treatments in the tumor-bearing mice. ¹³¹I-CD133mAb can inhibit the growth of liver cancer cells with a high CD133 expression both in vivo and in vitro.

  3. Tailoring of EIA-649-1: Definition of Major (Class I) Engineering Change Proposal

    DTIC Science & Technology

    2015-05-15

    MISSILE SYSTEMS CENTER TAILORING TAILORING OF EIA -649-1: DEFINITION OF MAJOR (CLASS I) ENGINEERING CHANGE PROPOSAL APPROVED FOR...PUBLIC RELEASE; DISTRIBUTION IS UNLIMITED 1 Tailoring of EIA -649-1: Definition of Major (Class I) ECP. 1. Intent of this Tailoring Document...This tailoring document remedies a requirements gap in the industry consensus standard, EIA -649-1: 2015. Specifically, this tailoring provides a

  4. Environmental impact assessment (EIA): an overlooked instrument for sustainable development in Pakistan.

    PubMed

    Saeed, Rashid; Sattar, Ayesha; Iqbal, Zafar; Imran, Muhammad; Nadeem, Raziya

    2012-04-01

    Environmental impact assessment (EIA) is a policy tool used for evaluating a project proposal from physical and socioeconomic environmental perspectives. Its aim is to reduce the impact of development on environment, hence, ensuring environmental sustainability. It is mandatory to submit an Environmental Impact Statement before starting a mega project as required by Environmental Protection Act of 1997 and Environmental Policy of Pakistan. Public consultation plays a key role in an EIA system, identifying the likely aspects and impacts of a development activity. This aspect has been ignored in effective enactment of environmental legislation in Pakistan. Sufficient legislative instruments are there to support EIA system in the country but the agencies responsible for the enforcement of environmental regulations have failed to do so. The current research gives an insight into the actual status of EIA system in Pakistan along with the feedback of EIA specialists and university teachers of the concerned departments. A new index has been devised on the basis of questionnaire response to work out the overall performance of EIA system in Pakistan or any other country. The weaknesses and deficiencies of each EIA stage have been worked out for Pakistan and elaborated with the help of the controversial Zero point Interchange Project in the capital city of Pakistan.

  5. New Dioxaborolane Chemistry Enables [18F]-Positron-Emitting, Fluorescent [18F]-Multimodality Biomolecule Generation from the Solid Phase

    PubMed Central

    Crisp, Jessica L.; Vera, David R.; Tsien, Roger Y.; Ting, Richard

    2016-01-01

    New protecting group chemistry is used to greatly simplify imaging probe production. Temperature and organic solvent-sensitive biomolecules are covalently attached to a biotin-bearing dioxaborolane, which facilitates antibody immobilization on a streptavidin-agarose solid-phase support. Treatment with aqueous fluoride triggers fluoride-labeled antibody release from the solid phase, separated from unlabeled antibody, and creates [18F]-trifluoroborate-antibody for positron emission tomography and near-infrared fluorescent (PET/NIRF) multimodality imaging. This dioxaborolane-fluoride reaction is bioorthogonal, does not inhibit antigen binding, and increases [18F]-specific activity relative to solution-based radiosyntheses. Two applications are investigated: an anti-epithelial cell adhesion molecule (EpCAM) monoclonal antibody (mAb) that labels prostate tumors and Cetuximab, an anti-epidermal growth factor receptor (EGFR) mAb (FDA approved) that labels lung adenocarcinoma tumors. Colocalized, tumor-specific NIRF and PET imaging confirm utility of the new technology. The described chemistry should allow labeling of many commercial systems, diabodies, nanoparticles, and small molecules for dual modality imaging of many diseases. PMID:27064381

  6. New Dioxaborolane Chemistry Enables [(18)F]-Positron-Emitting, Fluorescent [(18)F]-Multimodality Biomolecule Generation from the Solid Phase.

    PubMed

    Rodriguez, Erik A; Wang, Ye; Crisp, Jessica L; Vera, David R; Tsien, Roger Y; Ting, Richard

    2016-05-18

    New protecting group chemistry is used to greatly simplify imaging probe production. Temperature and organic solvent-sensitive biomolecules are covalently attached to a biotin-bearing dioxaborolane, which facilitates antibody immobilization on a streptavidin-agarose solid-phase support. Treatment with aqueous fluoride triggers fluoride-labeled antibody release from the solid phase, separated from unlabeled antibody, and creates [(18)F]-trifluoroborate-antibody for positron emission tomography and near-infrared fluorescent (PET/NIRF) multimodality imaging. This dioxaborolane-fluoride reaction is bioorthogonal, does not inhibit antigen binding, and increases [(18)F]-specific activity relative to solution-based radiosyntheses. Two applications are investigated: an anti-epithelial cell adhesion molecule (EpCAM) monoclonal antibody (mAb) that labels prostate tumors and Cetuximab, an anti-epidermal growth factor receptor (EGFR) mAb (FDA approved) that labels lung adenocarcinoma tumors. Colocalized, tumor-specific NIRF and PET imaging confirm utility of the new technology. The described chemistry should allow labeling of many commercial systems, diabodies, nanoparticles, and small molecules for dual modality imaging of many diseases.

  7. Transient behaviour of EIT and EIA in an optical-radio two-photon coupling configuration

    NASA Astrophysics Data System (ADS)

    Li, Xiaoli; Yang, Zicai; Shang, Yaxuan

    2012-11-01

    Both electromagnetically induced absorption (EIA) and transparency (EIT) can be obtained in a modified quasi-lambda four level system consisting of an optical-radio two-photon coupling field and a probing field. A physical account of EIA and EIT is given in terms of a transient state picture in this paper. It can be seen that the optical coupling field in this quasi-lambda four level system has a crucial effect on the forming of EIA and EIT. An EIA is observed under a resonant optical coupling and it evolves into an EIT when there is a detuning.

  8. Detection of RSV Antibodies in Human Plasma by Enzyme Immunoassays.

    PubMed

    Jadhao, Samadhan J; Anderson, Larry J

    2016-01-01

    Enzyme immunoassays (EIAs) to detect and quantify antibodies against respiratory syncytial virus (RSV) and RSV proteins in human plasma or sera are described. The first EIA uses RSV lysate antigens produced in HEp-2 cell line. The second EIA uses RSV F or G gene-expressed antigen in HEp-2 cells. The third EIA uses 30-amino acid synthetic peptides from central conserved region of G protein of RSV A2 or RSV B1 virus and a peptide from the SARS CoV nucleoprotein as a negative control peptide. All three EIAs have been evaluated for detecting and quantifying the respective antibodies in human sera or plasma.

  9. Effect of Chelator Conjugation Level and Injection Dose on Tumor and Organ Uptake of 111In Labeled MORAb-009, an Anti-mesothelin Antibody

    PubMed Central

    Shin, I. S.; Lee, S.-M.; Kim, H. S.; Yao, Z.; Regino, C.; Sato, N.; Cheng, K. T.; Hassan, R.; Campo, M. F.; Albone, E. F.; Choyke, P. L.; Pastan, I.; Paik, C. H.

    2012-01-01

    Introduction Radiolabeling of a monoclonal antibody (mAb) with a metallic radionuclide requires the conjugation of a bifunctional chelator to the mAb. The conjugation, however, can alter the physical and immunological properties of the mAb, consequently affecting its tumor targeting pharmacokinetics. In this study, we investigated the effect of the amount of 2-(p-isothiocyanatobenzyl)-cyclohexyl-diethylenetriamine-pentaacetic acid (CHX-A″) conjugated to MORAb-009, a mAb directed against mesothelin and the effect of MORAb dose on the biodistribution of 111In labeled MORAb-009. Methods We used nude mice bearing A431/K5 tumor as a mesothelin-positive tumor model and A431 tumor as a mesothelin-negative control. To find the optimal level of CHX-A″ conjugation, CHX-A″-MORAb-009 conjugates with 2.4, 3.5, and 5.5 CHX-A″ molecules were investigated. To investigate the effect of injected MORAb-009 dose on neutralizing the shed-mesothelin in the circulation, the biodistribution studies were performed after the i.v. co-injection of the 111In labeled MORAb-009 (2.4 CHX-A″/MORAb-009) with three different doses, 0.2, 2, and 30 μg of MORAb-009. Results The tumor uptake in A431/K5 tumor was 4 times higher than that in A431 tumor, indicating that the tumor uptake in A431/K5 was mesothelin-mediated. The conjugate with 5.5 CHX-A″ showed a lower isoelectric point (pI) and lower immunoreactivity (IR) than the 2.4 CHX-A″ conjugate. These differences were reflected in biodistribution of the 111In label. The 111In labeled MORAb-009 conjugated with 2.4 CHX-A″ produced higher tumor uptake, and lower liver and spleen uptakes than the 5.5 CHX-A″ conjugate. The biodistribution studies also revealed that the tumor uptake was significantly affected by the injected MORAb-009 dose and tumor size. The 30 μg dose produced higher tumor uptake than the 0.2 and 2 μg doses whereas the 30 μg dose produced lower liver and spleen uptakes than the 0.2 μg dose. Conclusion This study demonstrates that the number of chelate conjugation and the injected dose are two important parameters to achieve high tumor and low non-target organ uptake of 111In labeled MORAb-009. This study also suggests that the injected dose of mAb could be individualized based on the tumor size or the blood level of shed-antigen in a patient to achieve the ideal tumor-to-organ radioactivity ratios. PMID:21741258

  10. Effect of chelator conjugation level and injection dose on tumor and organ uptake of 111In-labeled MORAb-009, an anti-mesothelin antibody.

    PubMed

    Shin, In Soo; Lee, Sang-Myung; Kim, Hyung Sub; Yao, Zhengsheng; Regino, Celeste; Sato, Noriko; Cheng, Kenneth T; Hassan, Raffit; Campo, Melissa F; Albone, Earl F; Choyke, Peter L; Pastan, Ira; Paik, Chang H

    2011-11-01

    Radiolabeling of a monoclonal antibody (mAb) with a metallic radionuclide requires the conjugation of a bifunctional chelator to the mAb. The conjugation, however, can alter the physical and immunological properties of the mAb, consequently affecting its tumor-targeting pharmacokinetics. In this study, we investigated the effect of the amount of 2-(p-isothiocyanatobenzyl)-cyclohexyl-diethylenetriamine-pentaacetic acid (CHX-A″) conjugated to MORAb-009, a mAb directed against mesothelin, and the effect of MORAb dose on the biodistribution of (111)In-labeled MORAb-009. We used nude mice bearing the A431/K5 tumor as a mesothelin-positive tumor model and the A431 tumor as a mesothelin-negative control. To find the optimal level of CHX-A″ conjugation, CHX-A″-MORAb-009 conjugates with 2.4, 3.5 and 5.5 CHX-A″ molecules were investigated. To investigate the effect of injected MORAb-009 dose on neutralizing the shed mesothelin in the circulation, biodistribution studies were performed after the intravenous co-injection of (111)In-labeled MORAb-009 (2.4 CHX-A″/MORAb-009) with three different doses: 0.2, 2 and 30 μg of MORAb-009. The tumor uptake in A431/K5 tumor was four times higher than that in A431 tumor, indicating that the tumor uptake in A431/K5 was mesothelin mediated. The conjugate with 5.5 CHX-A″ showed a lower isoelectric point (pI) and lower immunoreactivity (IR) than the 2.4 CHX-A″ conjugate. These differences were reflected in the biodistribution of the (111)In label. The (111)In-labeled MORAb-009 conjugated with 2.4 CHX-A″ produced higher tumor uptake and lower liver and spleen uptakes than the 5.5 CHX-A″ conjugate. The biodistribution studies also revealed that the tumor uptake was significantly affected by the injected MORAb-009 dose and tumor size. The 30-μg dose produced higher tumor uptake than the 0.2- and 2-μg doses, whereas the 30-μg dose produced lower liver and spleen uptakes than the 0.2-μg dose. This study demonstrates that the number of chelate conjugation and the injected dose are two important parameters to achieve high tumor and low non-target organ uptake of (111)In-labeled MORAb-009. This study also suggests that the injected dose of mAb could be individualized based on the tumor size or the blood level of shed antigen in a patient to achieve the ideal tumor-to-organ radioactivity ratios. Published by Elsevier Inc.

  11. Comparison of 2 Assays for Diagnosing Rotavirus and Evaluating Vaccine Effectiveness in Children with Gastroenteritis

    PubMed Central

    Mijatovic-Rustempasic, Slavica; Tam, Ka Ian; Lyde, Freda C.; Payne, Daniel C.; Szilagyi, Peter; Edwards, Kathryn; Staat, Mary Allen; Weinberg, Geoffrey A.; Hall, Caroline B.; Chappell, James; McNeal, Monica; Gentsch, Jon R.; Bowen, Michael D.; Parashar, Umesh D.

    2013-01-01

    We compared rotavirus detection rates in children with acute gastroenteritis (AGE) and in healthy controls using enzyme immunoassays (EIAs) and semiquantitative real-time reverse transcription PCR (qRT-PCR). We calculated rotavirus vaccine effectiveness using different laboratory-based case definitions to determine which best identified the proportion of disease that was vaccine preventable. Of 648 AGE patients, 158 (24%) were EIA positive, and 157 were also qRT-PCR positive. An additional 65 (10%) were qRT-PCR positive but EIA negative. Of 500 healthy controls, 1 was EIA positive and 24 (5%) were qRT-PCR positive. Rotavirus vaccine was highly effective (84% [95% CI 71%–91%]) in EIA-positive children but offered no significant protection (14% [95% CI −105% to 64%]) in EIA-negative children for whom virus was detected by qRT-PCR alone. Children with rotavirus detected by qRT-PCR but not by EIA were not protected by vaccination, suggesting that rotavirus detected by qRT-PCR alone might not be causally associated with AGE in all patients. PMID:23876518

  12. EIA Household Energy Use Data Now Includes Detail on 16 States

    EIA Publications

    2011-01-01

    The Energy Information Administration (EIA) is releasing new benchmark estimates for home energy use for the year 2009 that include detailed data for 16 states, 12 more than in past EIA residential energy surveys.

  13. Overestimation of the 25(OH)D serum concentration with the automated IDS EIA kit.

    PubMed

    Cavalier, Etienne; Huberty, Véronique; Cormier, Catherine; Souberbielle, Jean-Claude

    2011-02-01

    We have recently observed an increasing number of patients presenting very high serum levels of 25-hydroxyvitamin D [25(OH)D] (> 150 ng/mL), which, in all cases, had been measured with the IDS EIA kit adapted on different "open" automated platforms. We performed a comparison between the IDS EIA kit adapted on two different "open"automated platforms and the DiaSorin RIA. We found a systematic bias (higher levels with the IDS EIA kit) for concentrations more than 50-60 ng/mL that was less obvious when the IDS EIA was used in its manual procedure. We thus suggest to use the IDS EIA kit in its manual procedure rather than to adapt it on an automated platform, and to interpret cautiously a 25(OH)D greater than 100 ng/mL with this kit. Copyright © 2011 American Society for Bone and Mineral Research.

  14. Can a toxin gene NAAT be used to predict toxin EIA and the severity of Clostridium difficile infection?

    PubMed

    Garvey, Mark I; Bradley, Craig W; Wilkinson, Martyn A C; Holden, Elisabeth

    2017-01-01

    Diagnosis of C. difficile infection (CDI) is controversial because of the many laboratory methods available and their lack of ability to distinguish between carriage, mild or severe disease. Here we describe whether a low C. difficile toxin B nucleic acid amplification test (NAAT) cycle threshold (CT) can predict toxin EIA, CDI severity and mortality. A three-stage algorithm was employed for CDI testing, comprising a screening test for glutamate dehydrogenase (GDH), followed by a NAAT, then a toxin enzyme immunoassay (EIA). All diarrhoeal samples positive for GDH and NAAT between 2012 and 2016 were analysed. The performance of the NAAT CT value as a classifier of toxin EIA outcome was analysed using a ROC curve; patient mortality was compared to CTs and toxin EIA via linear regression models. A CT value ≤26 was associated with ≥72% toxin EIA positivity; applying a logistic regression model we demonstrated an association between low CT values and toxin EIA positivity. A CT value of ≤26 was significantly associated ( p  = 0.0262) with increased one month mortality, severe cases of CDI or failure of first line treatment. The ROC curve probabilities demonstrated a CT cut off value of 26.6. Here we demonstrate that a CT ≤26 indicates more severe CDI and is associated with higher mortality. Samples with a low CT value are often toxin EIA positive, questioning the need for this additional EIA test. A CT ≤26 could be used to assess the potential for severity of CDI and guide patient treatment.

  15. Directory of Energy Information Administration model abstracts 1988

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1988-01-01

    This directory contains descriptions about each basic and auxiliary model, including the title, acronym, purpose, and type, followed by more detailed information on characteristics, uses, and requirements. For developing models, limited information is provided. Sources for additional information are identified. Included in this directory are 44 EIA models active as of February 1, 1988; 16 of which operate on personal computers. Models that run on personal computers are identified by ''PC'' as part of the acronyms. The main body of this directory is an alphabetical listing of all basic and auxiliary EIA models. Appendix A identifies major EIA modeling systemsmore » and the models within these systems, and Appendix B identifies EIA models by type (basic or auxiliary). Appendix C lists developing models and contact persons for those models. A basic model is one designated by the EIA Administrator as being sufficiently important to require sustained support and public scrutiny. An auxiliary model is one designated by the EIA Administrator as being used only occasionally in analyses, and therefore requires minimal levels of documentation. A developing model is one designated by the EIA Administrator as being under development and yet of sufficient interest to require a basic level of documentation at a future date. EIA also leases models developed by proprietary software vendors. Documentation for these ''proprietary'' models is the responsibility of the companies from which they are leased. EIA has recently leased models from Chase Econometrics, Inc., Data Resources, Inc. (DRI), the Oak Ridge National Laboratory (ORNL), and Wharton Econometric Forecasting Associates (WEFA). Leased models are not abstracted here.« less

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cardenas, Ibsen C., E-mail: c.cardenas@utwente.nl; Halman, Johannes I.M., E-mail: J.I.M.Halman@utwente.nl

    Uncertainty is virtually unavoidable in environmental impact assessments (EIAs). From the literature related to treating and managing uncertainty, we have identified specific techniques for coping with uncertainty in EIAs. Here, we have focused on basic steps in the decision-making process that take place within an EIA setting. More specifically, we have identified uncertainties involved in each decision-making step and discussed the extent to which these can be treated and managed in the context of an activity or project that may have environmental impacts. To further demonstrate the relevance of the techniques identified, we have examined the extent to which themore » EIA guidelines currently used in Colombia consider and provide guidance on managing the uncertainty involved in these assessments. Some points that should be considered in order to provide greater robustness in impact assessments in Colombia have been identified. These include the management of stakeholder values, the systematic generation of project options, and their associated impacts as well as the associated management actions, and the evaluation of uncertainties and assumptions. We believe that the relevant and specific techniques reported here can be a reference for future evaluations of other EIA guidelines in different countries. - Highlights: • uncertainty is unavoidable in environmental impact assessments, EIAs; • we have identified some open techniques to EIAs for treating and managing uncertainty in these assessments; • points for improvement that should be considered in order to provide greater robustness in EIAs in Colombia have been identified; • the paper provides substantiated a reference for possible examinations of EIAs guidelines in other countries.« less

  17. Directory of Energy Information Administration model abstracts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1987-08-11

    This report contains brief statements from the model managers about each model's title, acronym, purpose, and status, followed by more detailed information on characteristics, uses, and requirements. Sources for additional information are identified. All models ''active'' through March 1987 are included. The main body of this directory is an alphabetical list of all active EIA models. Appendix A identifies major EIA modeling systems and the models within these systems, and Appendix B identifies active EIA models by type (basic, auxiliary, and developing). A basic model is one designated by the EIA Administrator as being sufficiently important to require sustained supportmore » and public scrutiny. An auxiliary model is one designated by the EIA Administrator as being used only occasionally in analyses, and therefore requires minimal levels of documentation. A developing model is one designated by the EIA Administrator as being under development and yet of sufficient interest to require a basic level of documentation at a future date. EIA also leases models developed by proprietary software vendors. Documentation for these ''proprietary'' models is the responsibility of the companies from which they are leased. EIA has recently leased models from Chase Econometrics, Inc., Data Resources, Inc. (DRI), the Oak Ridge National Laboratory (ORNL), and Wharton Econometric Forecasting Associates (WEFA). Leased models are not abstracted here. The directory is intended for the use of energy and energy-policy analysts in the public and private sectors.« less

  18. Effects of impervious area and BMP implementation and design on storm runoff and water quality in eight small watersheds

    USGS Publications Warehouse

    Aulenbach, Brent T.; Landers, Mark N.; Musser, Jonathan W.; Painter, Jaime A.

    2017-01-01

    The effects of increases in effective impervious area (EIA) and the implementation of water quality protection designed detention pond best management practices (BMPs) on storm runoff and stormwater quality were assessed in Gwinnett County, Georgia, for the period 2001-2008. Trends among eight small watersheds were compared, using a time trend study design. Significant trends were detected in three storm hydrologic metrics and in five water quality constituents that were adjusted for variability in storm characteristics and climate. Trends in EIA ranged from 0.10 to 1.35, and changes in EIA treated by BMPs ranged from 0.19 to 1.32; both expressed in units of percentage of drainage area per year. Trend relations indicated that for every 1% increase in watershed EIA, about 2.6, 1.1, and 1.5% increases in EIA treated by BMPs would be required to counteract the effects of EIA added to the watersheds on peak streamflow, stormwater yield, and storm streamflow runoff, respectively. Relations between trends in EIA, BMP implementation, and water quality were counterintuitive. This may be the result of (1) changes in constituent inputs in the watersheds, especially downstream of areas treated by BMPs; (2) BMPs may have increased the duration of stormflow that results in downstream channel erosion; and/or (3) spurious relationships between increases in EIA, BMP implementation, and constituent inputs with development rates.

  19. Bacterial quality and safety of packaged fresh leafy vegetables at the retail level in Finland.

    PubMed

    Nousiainen, L-L; Joutsen, S; Lunden, J; Hänninen, M-L; Fredriksson-Ahomaa, M

    2016-09-02

    Consumption of packaged fresh leafy vegetables, which are convenient ready-to-eat products, has increased during the last decade. The number of foodborne outbreaks associated with these products has concurrently increased. In our study, (1) label information, (2) O2/CO2 composition, (3) bacterial quality and (4) safety of 100 fresh leafy vegetables at the retail level were studied in Finland during 2013. Bacterial quality was studied using aerobic bacteria (AB) and coliform bacteria (CB) counts, and searching for the presence of Escherichia coli, Listeria and Yersinia. The safety was studied by the presence of Salmonella, ail-positive Yersinia, stx-positive E. coli (STEC) and Listeria monocytogenes using PCR and culturing. Important label information was unavailable on several packages originating from different companies. The packaging date was missing on all packages and the date of durability on 83% of the packages. Storage temperature was declared on 62% of the packages and 73% of the packages contained information about prewashing. The batch/lot number was missing on 29% of the packages. Very low oxygen (O2) (<1%) and elevated carbon dioxide (CO2) (2-22%) concentrations were measured in all packages labelled to contain a protective atmosphere. O2 and CO2 concentrations varied widely in the rest of the packages. AB and CB counts were high in the leafy vegetable samples varying between 6.2 and 10.6 and 4.2-8.3logcfu/g, respectively. In most of the samples, the AB and CB counts exceeded 10(8) and 10(6)cfu/g, respectively. A positive correlation was observed between the AB and CB counts. E. coli was isolated from 15% of the samples and Yersinia from 33%. L. monocytogenes was isolated from two samples and ail-positive Y. enterocolitica in one. Using PCR, STEC was detected in seven samples, and Salmonella and ail-positive Y. enterocolitica in two samples each. The AB and CB mean values of products originating from different companies varied widely. High AB and CB counts and pathogenic bacteria were detected in ready-to-eat products not needing washing before use. Our study shows that the bacterial quality and safety of packaged fresh leafy vegetables is poor and label information on the packages is inadequate. More studies are needed concerning the impact of a protective atmosphere on bacterial growth, and the impact of washing for removing bacteria. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Training for Environmental Impact Assessment (E.I.A.).

    ERIC Educational Resources Information Center

    Vougias, S.

    1988-01-01

    Deals with the methodology and practices for Environmental Impact Assessment (EIA). Describes the EIA process, prediction process, alternative assessment methods, training needs, major activities, training provision and material, main deficiencies and the precautions, and real world training examples. (Author/YP)

  1. Structural analysis of N-glycans by the glycan-labeling method using 3-aminoquinoline-based liquid matrix in negative-ion MALDI-MS.

    PubMed

    Nishikaze, Takashi; Kaneshiro, Kaoru; Kawabata, Shin-ichirou; Tanaka, Koichi

    2012-11-06

    Negative-ion fragmentation of underivatized N-glycans has been proven to be more informative than positive-ion fragmentation. Fluorescent labeling via reductive amination is often employed for glycan analysis, but little is known about the influence of the labeling group on negative-ion fragmentation. We previously demonstrated that the on-target glycan-labeling method using 3-aminoquinoline/α-cyano-4-hydroxycinnamic acid (3AQ/CHCA) liquid matrix enables highly sensitive, rapid, and quantitative N-glycan profiling analysis. The current study investigates the suitability of 3AQ-labeled N-glycans for structural analysis based on negative-ion collision-induced dissociation (CID) spectra. 3AQ-labeled N-glycans exhibited simple and informative CID spectra similar to those of underivatized N-glycans, with product ions due to cross-ring cleavages of the chitobiose core and ions specific to two antennae (D and E ions). The interpretation of diagnostic fragment ions suggested for underivatized N-glycans could be directly applied to the 3AQ-labeled N-glycans. However, fluorescently labeled N-glycans by conventional reductive amination, such as 2-aminobenzamide (2AB)- and 2-pyrydilamine (2PA)-labeled N-glycans, exhibited complicated CID spectra consisting of numerous signals formed by dehydration and multiple cleavages. The complicated spectra of 2AB- and 2PA-labeled N-glycans was found to be due to their open reducing-terminal N-acetylglucosamine (GlcNAc) ring, rather than structural differences in the labeling group in the N-glycan derivative. Finally, as an example, the on-target 3AQ labeling method followed by negative-ion CID was applied to structurally analyze neutral N-glycans released from human epidermal growth factor receptor type 2 (HER2) protein. The glycan-labeling method using 3AQ-based liquid matrix should facilitate highly sensitive quantitative and qualitative analyses of glycans.

  2. Evaluation of the C6 Lyme Enzyme Immunoassay for the Diagnosis of Lyme Disease in Children and Adolescents.

    PubMed

    Lipsett, Susan C; Branda, John A; McAdam, Alexander J; Vernacchio, Louis; Gordon, Caroline D; Gordon, Catherine R; Nigrovic, Lise E

    2016-10-01

    The commercially-available C6 Lyme enzyme immunoassay (EIA) has been approved to replace the standard whole-cell sonicate EIA as a first-tier test for the diagnosis of Lyme disease and has been suggested as a stand-alone diagnostic. However, the C6 EIA has not been extensively studied in pediatric patients undergoing evaluation for Lyme disease. We collected discarded serum samples from children and adolescents (aged ≤21 years) undergoing conventional 2-tiered testing for Lyme disease at a single hospital-based clinical laboratory located in an area endemic for Lyme disease. We performed a C6 EIA on all collected specimens, followed by a supplemental immunoblot if the C6 EIA result was positive but the whole-cell sonicate EIA result was negative. We defined a case of Lyme disease as either a clinician-diagnosed erythema migrans lesion or a positive standard 2-tiered serologic result in a patient with symptoms compatible with Lyme disease. We then compared the performance of the C6 EIA alone and as a first-tier test followed by immunoblot, with that of standard 2-tiered serology for the diagnosis of Lyme disease. Of the 944 specimens collected, 114 (12%) were from patients with Lyme disease. The C6 EIA alone had sensitivity similar to that of standard 2-tiered testing (79.8% vs 81.6% for standard 2-tiered testing; P = .71) with slightly lower specificity (94.2% vs 98.8% 2; P < .002). Addition of a supplemental immunoblot improved the specificity of the C6 EIA to 98.6%. For children and adolescents undergoing evaluation for Lyme disease, the C6 EIA could guide initial clinical decision making, although a supplemental immunoblot should still be performed. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.

  3. Antibodies against mumps virus component proteins.

    PubMed

    Matsubara, Keita; Iwata, Satoshi; Nakayama, Tetsuo

    2012-08-01

    The neutralization (NT) test is regarded as the most reliable method for detection of protective antibodies, but is labor-intensive and time consuming. Enzyme-linked immunosorbent assay (EIA) is frequently used in sero-epidemiological studies because of its simplicity and ease of use. In this study, immunofluorescent (IF) antibodies against nucleocapsid (N), fusion (F), and hemagglutinin-neuraminidase (HN) proteins were investigated in comparison with NT and EIA antibodies. The antibody against N protein was dominant in serum samples obtained from patients with a previous history of mumps infection. Titers of antibodies against F and HN proteins were very low. Many serum samples were positive for EIA but negative for NT, and no significant correlation was noted between NT and EIA antibodies. Among the three component proteins, correlation of EIA and IF antibodies with N protein was relatively good. After vaccination with mumps vaccine, EIA positivity was closely related to the IF antibodies against N protein, and after vaccination NT-positive sera became positive for IF antibodies against F and HN proteins. IF antibodies against F and HN proteins were considered to have a strong association with NT antibodies, and those against N protein were considered to have a strong association with EIA antibodies.

  4. 47 CFR 90.548 - Interoperability Technical Standards.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Standards, approved March 3, 2000, Telecommunications Industry Association, ANSI/TIA/EIA-102.BAEA-2000..., approved March 3, 2000, Telecommunications Industry Association, ANSI/TIA/EIA-102.BAEB-2000; Project 25..., approved March 3, 2000, Telecommunications Industry Association, ANSI/TIA/EIA-102.BAEE-2000; Project 25...

  5. Ultrasensitive Nanoimmunosensor by coupling non-covalent functionalized graphene oxide platform and numerous ferritin labels on carbon nanotubes.

    PubMed

    Akter, Rashida; Jeong, Bongjin; Choi, Jong-Soon; Rahman, Md Aminur

    2016-06-15

    An ultrasensitive electrochemical nanostructured immunosensor for a breast cancer biomarker carbohydrate antigen 15-3 (CA 15-3) was fabricated using non-covalent functionalized graphene oxides (GO/Py-COOH) as sensor probe and multiwalled carbon nanotube (MWCNTs)-supported numerous ferritin as labels. The immunosensor was constructed by immobilizing a monoclonal anti-CA 15-3 antibody on the GO modified cysteamine (Cys) self-assembled monolayer (SAM) on an Au electrode (Au/Cys) through the amide bond formation between the carboxylic acid groups of GO/Py-COOH and amine groups of anti-CA 15-3. Secondary antibody conjugated MWCNT-supported ferritin labels (Ab2-MWCNT-Ferritin) were prepared through the amide bond formation between amine groups of Ab2 and ferritin and carboxylic acid groups of MWCNTs. The detection of CA 15-3 was based on the enhanced bioelectrocatalytic reduction of hydrogen peroxide mediated by hydroquinone (HQ) at the GO/Py-COOH-based sensor probe. The GO/Py-COOH-based sensor probe and Ab2-MWCNT-Ferritin labels were characterized using cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), scanning electron microscope (SEM), transmission electron microscope (TEM), and x-ray photoelectron spectroscopy (XPS) techniques. Using differential pulse voltammetry (DPV) technique, CA 15-3 can be selectively detected as low as 0.01 ± 0.07 U/mL in human serum samples. Additionally, the proposed CA 15-3 immunosensor showed excellent selectivity and better stability in human serum samples, which demonstrated that the proposed immunosensor has potentials in proteomic researches and diagnostics. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Coal Transportation Rates to the Electric Power Sector

    EIA Publications

    2015-01-01

    The Energy Information Administration (EIA) releases new data on coal transportation rates to the electric power sector to incorporate new EIA survey data from the EIA-923. This expanded coverage enables EIA to publish data over numerous routes that were previously withheld due to confidentiality concerns. It allowed for more in-depth analysis especially for state to state rates. Another feature of this release is the incorporation – for the first time – of coal transport rates by barge and truck.

  7. Evaluation of the Specificity of Two Enzyme Immunoassays for Coccidioidomycosis by Using Sera from a Region of Endemicity and a Region of Nonendemicity

    PubMed Central

    Ahn, YoonJi; McCotter, Orion; Gade, Lalitha; Hurst, Steven F.; Brandt, Mary E.; Park, Benjamin J.; Litvintseva, Anastasia P.

    2015-01-01

    Coccidioidomycosis (CM), a serious life-threatening fungal infection endemic to arid regions of the western United States and Mexico, can be challenging to diagnose in a timely manner. Commercially developed enzyme immunoassays (EIAs) (from Meridian Biosciences and Immuno-Mycologics [IMMY]) have provided faster, simpler means for serodiagnosis; however, independent evaluations have questioned EIA specificity, particularly IgM-positive/IgG-negative results. This study was conducted to evaluate EIA specificity among persons residing in Puerto Rico (n = 534), where CM is not endemic (who were not likely to have been exposed to Coccidioides spp.), compared to blood bank donors residing in Arizona (n = 1,218), where CM is endemic. Upon comparing serum reactivity between Puerto Rico and Arizona, the Meridian EIA showed a significant difference in IgG reactivity (0.37% versus 3.6%; P < 0.001) but not IgM reactivity (3.4% versus 2.4%; P = 0.31). No IgM-/IgG-reactive sera were detected among sera from Puerto Rico, compared to 7 (0.57%) sera from Arizona. Similar results were observed using the IMMY EIA, although significantly (P = 0.03) fewer IgM-reactive sera from Arizona were observed, compared to the Meridian EIA. EIA-reactive sera were also evaluated by immunodiffusion before and after 3- to 4-fold concentration of the sera. These results demonstrate that elevated IgG EIA reactivity is present in sera from healthy individuals in regions of endemicity and that IgM EIA reactivity observed in sera from individuals residing outside regions of endemicity is most likely nonspecific. Other criteria, including clinical and microbiological evaluations, should be taken into account when interpreting results from surveillance studies and other reporting measures. PMID:26245352

  8. Bottom-up responses to environmental and social impact assessments: A case study from Guatemala

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aguilar-Støen, Mariel, E-mail: mariel.stoen@sum.uio.no; Hirsch, Cecilie; Department of International Environment and Development, Norwegian University of Life Sciences

    In this article we take a closer look at resistance to the practice of Environmental Impact Assessment (EIA) in mining and energy projects in Guatemala. Collectivities resisting mining and hydropower projects in Guatemala are increasingly using the evaluations of EIAs conducted by international independent professionals. Reaching out to international experts is facilitated by local communities' engagements in transnational networks bringing together activists, NGOs, scientists, journalists and others. We argue that resistance movements resort to international professionals to challenge the limits imposed on them by the national legislation and institutional arrangements as well as by the way in which EIAs aremore » performed in the country. Further, the engagements in networks that facilitate access to knowledge contribute to strengthen the legitimacy of communities' claims. Challenges to and complaints about EIAs are ways in which affected communities try to reclaim their right to participate in decision-making related to their local environment and the development of their communities. Both complaints about EIAs and the use of transnational networks to attain better participation in decision making processes at local levels, illustrated in this study for Guatemala, are common responses to the advancement of extractive industries and hydropower development across Latin America. The widespread of initiatives to challenge EIAs involving international experts in the region show that EIAs have become a sort of a transnational battleground. - Highlights: • Communities’ opposition to extractive projects is rooted in lack of participation in decision-making, including EIAs • Experts’ evaluations of approved EIAs confirm communities’ claims of poor practices in the public sector • Research presented here shows that local communities linked to transnational networks are able to scale up their demands.« less

  9. Detection of phase I IgG antibodies to Coxiella burnetii with EIA as a screening test for blood donations.

    PubMed

    van der Hoek, W; Wielders, C C H; Schimmer, B; Wegdam-Blans, M C A; Meekelenkamp, J; Zaaijer, H L; Schneeberger, P M

    2012-11-01

    The presence of a high phase I IgG antibody titre may indicate chronic infection and a risk for the transmission of Coxiella burnetii through blood transfusion. The outbreak of Q fever in the Netherlands allowed for the comparison of an enzyme immunoassay (EIA) with the reference immunofluorescence assay (IFA) in a large group of individuals one year after acute Q fever. EIA is 100 % sensitive in detecting high (≥1:1,024) phase I IgG antibody titres. The cost of screening with EIA and confirming all EIA-positive results with IFA is much lower than screening all donations with IFA. This should be taken into account in cost-effectiveness analyses of screening programmes.

  10. Diagnosis and Management of Exercise-Induced Asthma.

    ERIC Educational Resources Information Center

    Rupp, Ned T.

    1996-01-01

    Exercise-induced asthma (EIA) affects 12-15% of the population. This comprehensive guide suggests that nearly all individuals with EIA can be active, highlighting both pharmacologic and nonpharmacologic management of asthma and stressing the importance of rigorous patient education in controlling underlying asthma and EIA. (SM)

  11. Performance of a time-resolved fluorescence immunoassay for measuring varicella-zoster virus immunoglobulin G levels in adults and comparison with commercial enzyme immunoassays and Merck glycoprotein enzyme immunoassay.

    PubMed

    Maple, P A C; Gray, J; Breuer, J; Kafatos, G; Parker, S; Brown, D

    2006-02-01

    Highly sensitive and specific, quantitative assays are needed to detect varicella-zoster virus (VZV) immunoglobulin G in human sera, particularly for determining immune status and response following vaccination. A time-resolved fluorescence immunoassay (TRFIA) has been developed, and its performance was compared to that of two commercial enzyme immunoassays (EIAs) and Merck glycoprotein EIA (gpEIA). The TRFIA had equivalent sensitivity (97.8%) and high specificity (93.5%) in relation to gpEIA. A commercial (Behring) EIA compared favorably with TRFIA in terms of sensitivity (98.4%) but had lower specificity (80.7%). Another commercial EIA (Diamedix) had high specificity (97.1%) but low sensitivity (76.4%) compared to TRFIA if equivocal test results were treated as negative for VZV antibody. A novel feature of the TRFIA was that the cutoff was generated using population mixture modeling and was expressed in mIU/ml, as the assay was calibrated using the British standard VZV antibody.

  12. A retrospective study of owner-requested testing as surveillance for equine infectious anemia in Canada (2009-2012).

    PubMed

    Higgins, Sara N; Howden, Krista J; James, Carolyn R; Epp, Tasha; Lohmann, Katharina L

    2017-12-01

    This retrospective study was undertaken to estimate i) the surveillance coverage for equine infectious anemia (EIA) based on owner-requested testing, and ii) the incidence of case detection from this surveillance activity to inform a review of Canada's national disease control strategy. Based on sample submissions by accredited veterinarians to laboratories CFIA-approved for EIA testing between 2009 and 2012, the estimated national surveillance coverage was 14% for all years, and 72 cases of EIA were detected. The annual national incidence of EIA detection ranged from 0.03 to 0.08 cases/1000 horses. On average, a greater proportion of the horse population was tested in eastern Canada (32%) than in western Canada (6%, P < 0.0001). The cumulative incidence of EIA detection was higher in western Canada (0.25 cases/1000 horses) than in eastern Canada (0.02 cases/1000 horses, P < 0.0001). This study identified regional differences in owner-requested EIA testing and case detection resulting from this testing activity.

  13. EIA models and capacity building in Viet Nam: an analysis of development aid programs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Doberstein, Brent

    2004-04-01

    There has been a decided lack of empirical research examining development aid agencies as 'agents of change' in environmental impact assessment (EIA) systems in developing countries, particularly research examining the model of environmental planning practice promoted by aid agencies as part of capacity building. This paper briefly traces a conceptual framework of EIA, then introduces the concept of 'EIA capacity building'. Using Viet Nam as a case study, the paper then outlines the empirical results of the research, focusing on the extent to which aid agency capacity-building programs promoted a Technical vs. Planning Model of EIA and on the coherencemore » of capacity-building efforts across all aid programs. A discussion follows, where research results are interpreted within the Vietnamese context, and implications of research results are identified for three main groups of actors. The paper concludes by calling for development aid agencies to reconceptualise EIA capacity building as an opportunity to transform developing countries' development planning processes.« less

  14. An innovative implementation of LCA within the EIA procedure: Lessons learned from two Wastewater Treatment Plant case studies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Larrey-Lassalle, Pyrène, E-mail: pyrene.larrey-lassalle@irstea.fr; LGEI, Ecole des mines d'Alès, 6 avenue de Clavières, 30319 Alès Cedex; Catel, Laureline

    Life Cycle Assessment (LCA) has been identified in the literature as a promising tool to increase the performance of environmental assessments at different steps in the Environmental Impact Assessment (EIA) procedure. However, few publications have proposed a methodology for an extensive integration, and none have compared the results with existing EIA conclusions without LCA. This paper proposes a comprehensive operational methodology for implementing an LCA within an EIA. Based on a literature review, we identified four EIA steps that could theoretically benefit from LCA implementation, i.e., (a) the environmental comparison of alternatives, (b) the identification of key impacts, (c) themore » impact assessment, and (d) the impact of mitigation measures. For each of these steps, an LCA was implemented with specific goal and scope definitions that resulted in a specific set of indicators. This approach has been implemented in two contrasting Wastewater Treatment Plant (WWTP) projects and compared to existing EIA studies. The results showed that the two procedures, i.e., EIAs with or without inputs from LCA, led to different conclusions. The environmental assessments of alternatives and mitigation measures were not carried out in the original studies and showed that other less polluting technologies could have been chosen. Regarding the scoping step, the selected environmental concerns were essentially different. Global impacts such as climate change or natural resource depletion were not taken into account in the original EIA studies. Impacts other than those occurring on the project site (off-site impacts) were not assessed, either. All these impacts can be significant compared to those initially considered. On the other hand, unlike current LCA applications, EIAs usually address natural and technological risks and neighbourhood disturbances such as noises or odours, which are very important for the public acceptability of projects. Regarding the impact assessment, even if the conclusions of the EIAs with or without LCA were partially common for local on-site impacts, LCA gives crucial additional information on global and off-site impacts and highlights the processes responsible for them. Finally, for all EIA steps investigated, interest in LCA was demonstrated for both WWTP case studies. The feasibility in terms of skills, time and cost of such implementation has also been assessed. - Highlights: • An innovative methodology for a first-stage implementation of LCA in EIA is proposed. • Its applicability is demonstrated on two Wastewater Treatment Plant case studies. • The conclusions for the four EIA steps investigated differ with or without LCA. • LCA provides valuable additional information on 1) global and 2) off-site impacts. • LCA identifies pollution transfers towards a life cycle perspective.« less

  15. A study on ionospheric scintillation near the EIA crest in relation to equatorial electrodynamics

    NASA Astrophysics Data System (ADS)

    Chatterjee, S.; Chakraborty, S. K.; Veenadhari, B.; Banola, S.

    2014-02-01

    Equatorial electrojet (EEJ) data, which are considered as a proxy index of equatorial electric field, are analyzed in conjunction with equatorial ionosonde, total electron content (TEC) and scintillation data near the equatorial ionization anomaly (EIA) crest for the equinoctial months of high solar activity years (2011-2012) to identify any precursor index of postsunset evolution of equatorial electron density irregularities and subsequent occurrence of scintillation near the northern EIA crest. Only geomagnetically quiet and normal electrojet days are considered. The diurnal profiles of EEJ on the scintillation days exhibit a secondary enhancement in the afternoon to presunset hours following diurnal peaks. A series of electrodynamical processes conducive for generation of irregularities emerge following secondary enhancement of EEJ. Latitudinal profile of TEC exhibits resurgence in EIA structure around the postsunset period. Diurnal TEC profile near the EIA crest resembles postsunset secondary enhancement on the days with afternoon enhancement in EEJ. Occurrence of equatorial spread F and postsunset scintillation near the EIA crest seems to follow the secondary enhancement events in EEJ. Both the magnitude and duration of enhanced EEJ are found to be important for postsunset intensification of EIA structure and subsequent occurrence of equatorial irregularities. A critical value combining the two may be considered an important precursor for postsunset occurrence of scintillation near the EIA crest. The results are validated using archived data for the years 1989-1990 and explained in terms of modulation effects of enhanced equatorial fountain.

  16. Critical factors for EIA implementation: literature review and research options.

    PubMed

    Zhang, Jie; Kørnøv, Lone; Christensen, Per

    2013-01-15

    After decades of development, the gap between expectations of Environment Impact Assessments (EIA) and their practical performance remains significant. Research has been done to identify the critical factors for an effective implementation of EIA. However, this research, to a large extent, has not been cumulated and analysed comprehensively according to the stages of the EIA process. This paper contributes to the critical review of the literature on EIA implementation and effectiveness by cumulating mainly empirical findings in an implementation theoretical perspective. It focuses on the links between different critical factors and how they relate to different stages in the EIA and thus influence the decision making process. After reviewing 33 refereed journal articles published between 1999 and 2011, we identified 203 notions of critical factors. Of these, 102 related to different stages defined in our comprehensive EIA implementation model, and 101 were identified as general factors related to the whole EIA system. The number of notions of stage factors and general factors is thus about equal. An overlap between stage factors and general factors was found, which demonstrates that critical factors function differently in different cases. The function of the critical factors is complex and it is difficult to determine contingencies and causations. In the sources we examined, there is evidently an imbalance between in-depth empirical research and general knowledge, and the paper offers some suggestions for future research. Copyright © 2012 Elsevier Ltd. All rights reserved.

  17. Nanotechnology-Enabled Optical Molecular Imaging of Breast Cancer

    DTIC Science & Technology

    2010-07-01

    Abbreviations Ab antibody AF-Ab Alexa Fluor labeled antibody CCD charge coupled device CTAB cetyltrimethylammonium bromide EDC 1-ethyl-[3-dimethylaminopropyl...mPEG-SH in figure 1. The carboxy-terminal nanorods were conjugated to antibodies using the zero-length crosslinker EDC stabilized by NHS [38]. Standard...multimode fiber coupler /positioner (Newport, model: F-915T) is utilized to mount the objective lens and a fiber chuck (Newport, model: FPH-DJ). With

  18. Magnetospheric disturbance effects on the Equatorial Ionization Anomaly (EIA) - An overview

    NASA Astrophysics Data System (ADS)

    Abdu, M. A.; Sobral, J. H. A.; de Paula, E. R.; Batista, I. S.

    1991-08-01

    The EIA response to magnetospheric disturbance processes is reviewed. It is concluded that the direct penetration to equatorial latitudes of magnetospheric electric fields and the thermospheric disturbances involving winds, electric fields, and composition changes produce significant alteration in the EIA morphology and dynamics.

  19. 77 FR 47048 - Agency Information Collection Extension

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-07

    ... collection requests a three-year extension of its Petroleum Marketing Program, OMB Control Number 1905-0174... as the needs of EIA's public and private customers. Data collected include costs, sales, prices, and... petroleum marketing survey forms listed below: EIA-14, ``Refiners' Monthly Cost Report'' EIA-182, ``Domestic...

  20. 78 FR 27370 - Proposed Change to Data Protection

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-10

    ... DEPARTMENT OF ENERGY U.S. Energy Information Administration Proposed Change to Data Protection... Production and Preparation Report--Coal Mines and Preparation Plants; and EIA-8A, the Coal Stocks Report-Traders and Brokers. EIA proposes to change and strengthen the data protection provisions on Forms EIA-3...

  1. 76 FR 3584 - Disclosure of Cochineal Extract and Carmine in the Labeling of Wines, Distilled Spirits, and Malt...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-20

    ... DEPARTMENT OF THE TREASURY Alcohol and Tobacco Tax and Trade Bureau 27 CFR Parts 5 [Docket No. TTB-2010-0008; Notice No. 111] RIN 1513-AB79 Disclosure of Cochineal Extract and Carmine in the Labeling of Wines, Distilled Spirits, and Malt Beverages Correction In proposed rule document 2010-27733 beginning...

  2. 77 FR 15362 - Proposed Agency Information Collection

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-15

    ....'' Schedule 2 of the Form EIA-923, ``Power Plant Operations Report,'' collects the cost and quality of fossil... primarily fueled by fossil fuels. The selection of respondents for Schedule 2 and its predecessors, the Form... EIA is soliciting comments on two proposed actions (1) revisions to the Form EIA-923, ``Power Plant...

  3. [Evaluation of hepatitis B virus genotyping EIA kit].

    PubMed

    Tanaka, Yasuhito; Sugauchi, Fuminaka; Matsuuraa, Kentaro; Naganuma, Hatsue; Tatematsu, Kanako; Takagi, Kazumi; Hiramatsu, Kumiko; Kani, Satomi; Gotoh, Takaaki; Wakimoto, Yukio; Mizokami, Masashi

    2009-01-01

    Clinical significance of Hepatitis B virus(HBV) genotyping is increasingly recognized. The aim of this study was to evaluate reproducibility, accuracy, and sensitivity of an enzyme immunoassay (EIA) based HBV genotyping kit, which designed to discriminate between genotypes to A, B, C, or D by detecting genotype-specific epitopes in PreS2 region. Using the four genotypes panels, the EIA demonstrated complete inter and intra-assay genotyping reproducibility. Serum specimens had stable results after 8 days at 4 degrees C, or 10 cycles of freezing-thawing. In 91 samples that have been genotyped by DNA sequencing, 87(95.6%) were in complete accordance with EIA genotyping. Of examined 344 HBsAg-positive serum specimens, genotypes A, B, C and D were determined in 26 (7.6%), 62 (18.0%), 228 (66.3%), and 9 (2.6%) cases, respectively. Of 19 (5.5%) specimens unclassified by the EIA, 13 were found to have low titer of HBsAg concentration (< 3 IU/ml), and the other 5 had amino acid mutations or deletions within targeted PreS2 epitopes. The EIA allowed genotyping even in HBV DNA negative samples (96.2%). In conclusion, HBV genotype EIA is reliable, sensitive and easy assay for HBV genotyping. The assay would be useful for clinical use.

  4. Vitamin B12 absorption judged by measurement of holotranscobalamin, active vitamin B12: evaluation of a commercially available EIA kit.

    PubMed

    Greibe, Eva; Nexo, Ebba

    2011-11-01

    Active vitamin B12 absorption is followed by an increase in holotranscobalamin (holoTC) upon loading with a high physiological dose of the vitamin (the CobaSorb test). This study evaluates the use of a newly launched EIA kit for measurement of holoTC (active B12) in relation to the CobaSorb test. Intra-assay imprecision and linearity of the EIA kit was examined, employing serum pools of increasing holoTC concentrations. For the CobaSorb test, holoTC was measured before and after loading with 3-times 9 μg of vitamin B12 employing both the in-house ELISA and the EIA kit (n=25). The EIA kit showed an intra-assay CV between 2.2% and 5.8% for holoTC values ranging from 21 to 80 pmol/L. Employing diluted serum samples resulted in spurious high values of holoTC. The EIA kit performed well in relation to the CobaSorb test and classified the patients studied as capable of absorbing vitamin B12 (n=10) or not (n=15), as did the in-house ELISA. The Active B12 (holoTC) EIA kit proved suitable for use with the CobaSorb test, but not for analysis of diluted serum samples.

  5. Temporal change of EIA asymmetry revealed by a beacon receiver network in Southeast Asia

    NASA Astrophysics Data System (ADS)

    Watthanasangmechai, Kornyanat; Yamamoto, Mamoru; Saito, Akinori; Maruyama, Takashi; Yokoyama, Tatsuhiro; Nishioka, Michi; Ishii, Mamoru

    2015-05-01

    To reveal the temporal change of the equatorial ionization anomaly (EIA) asymmetry, a multipoint satellite-ground beacon experiment was conducted along the meridional plane of the Thailand-Indonesia sector. The observation includes one station near the magnetic equator and four stations at off-equator latitudes. This is the first EIA asymmetry study with high spatial resolution using GNU Radio Beacon Receiver (GRBR) observations in Southeast Asia. GRBR-total electron contents (TECs) from 97 polar-orbit satellite passes in March 2012 were analyzed in this study. Successive passes captured rapid evolution of EIA asymmetry, especially during geomagnetic disturbances. The penetrating electric fields that occur during geomagnetic disturbed days are not the cause of the asymmetry. Instead, high background TEC associated with an intense electric field empowers the neutral wind to produce severe asymmetry of the EIA. Such rapid evolution of EIA asymmetry was not seen during nighttime, when meridional wind mainly controlled the asymmetric structures. Additional data are necessary to identify the source of the variations, i.e., atmospheric waves. Precisely capturing the locations of the crests and the evolution of the asymmetry enhances understanding of the temporal change of EIA asymmetry at the local scale and leads to a future local modeling for TEC prediction in Southeast Asia.

  6. Fluorescence correlation spectroscopy as a sensitive and useful tool for revealing potential overlaps between the epitopes of monoclonal antibodies on viral particles.

    PubMed

    Richert, Ludovic; Humbert, Nicolas; Larquet, Eric; Girerd-Chambaz, Yves; Manin, Catherine; Ronzon, Frédéric; Mély, Yves

    2016-10-01

    Although the enzyme-linked immunosorbent assay (ELISA) is well established for quantitating epitopes on inactivated virions used as vaccines, it is less suited for detecting potential overlaps between the epitopes recognized by different antibodies raised against the virions. We used fluorescent correlation spectroscopy (FCS) to detect the potential overlaps between 3 monoclonal antibodies (mAbs 4B7-1H8-2E10, 1E3-3G4, 4H8-3A12-2D3) selected for their ability to specifically recognize poliovirus type 3. Competition of the Alexa488-labeled mAbs with non-labeled mAbs revealed that mAbs 4B7-1H8-2E10 and 4H8-3A12-2D3 compete strongly for their binding sites on the virions, suggesting an important overlap of their epitopes. This was confirmed by the cryo-electron microscopy (cryo EM) structure of the poliovirus type 3 complexed with the corresponding antigen-binding fragments (Fabs) of the mAbs, which revealed that Fabs 4B7-1H8-2E10 and 4H8-3A12-2D3 epitopes share common amino acids. In contrast, a less efficient competition between mAb 1E3-3G4 and mAb 4H8-3A12-2D3 was observed by FCS, and there was no competition between mAbs 1E3-3G4 and 4B7-1H8-2E10. The Fab 1E3-3G4 epitope was found by cryoEM to be close to but distinct from the epitopes of both Fabs 4H8-3A12-2D3 and 4B7-1H8-2E10. Therefore, the FCS data additionally suggest that mAbs 4H8-3A12-2D3 and 4B7-1H8-2E10 bind in a different orientation to their epitopes, so that only the former sterically clashes with the mAb 1E3-3G4 bound to its epitope. Our results demonstrate that FCS can be a highly sensitive and useful tool for assessing the potential overlap of mAbs on viral particles.

  7. A three-time-point method for assessing kinetic parameters of 64Cu-labeled Ramucirumab trapping in VEGFR-2 positive lung tumors.

    PubMed

    Laffon, Eric; Marthan, Roger

    2017-11-01

    To describe a three-time-point method for estimating kinetic parameters involved in 64 Cu-labeled Ramucirumab ( 64 Cu-NOTA-RamAb) trapping of VEGFR-2 positive lung tumors. Positron emission tomography (microPET) data of tumor-bearing mice for 64 Cu-NOTA-RamAb trapping in VEGFR-2 positive HCC4006 tumor were used, involving tissue activity measurements acquired at 3, 24 and 48 h post-injection, without and with administration of RamAb blocking dose. A kinetic model provided an analytical formula describing the tissue time-activity-curve, involving 64 Cu-NOTA-RamAb uptake (Ki), release rate constant (k R ) and fraction of free tracer in blood and interstitial volume (F). Fitting analytical formula outcomes on mean microPET data yielded values of the kinetic parameters: Ki = 0.0314/0.0123 gram of blood per hour per gram of tissue, k R  = 0.0387/0.0313 h -1 and F = 0.2075/0.2007 gram of blood per gram of tissue, without/with RamAb blocking dose, respectively (R = 0.99999 for the graph displaying microPET versus theoretical data; P < .01). Three independent kinetic parameters (Ki, k R and F) can be assessed from three data points acquired at early, mid and late imaging, i.e., at 3, 24 and 48 h post-injection, for further characterization of 64 Cu-NOTA-RamAb trapping in VEGFR-2 positive lung tumors. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  8. Verification of the harmonization of human epididymis protein 4 assays.

    PubMed

    Ferraro, Simona; Borille, Simona; Carnevale, Assunta; Frusciante, Erika; Bassani, Niccolò; Panteghini, Mauro

    2016-10-01

    Serum human epididymis protein 4 (HE4) has gained relevance as an ovarian cancer (OC) biomarker and new automated methods have replaced the first released manual EIA by tracing results to it. We verified agreement and bias of automated methods vs. EIA as well as possible effects on patients' management. One hundred and fifteen serum samples were measured by Abbott Architect i2000, Fujirebio Lumipulse G1200, Roche Modular E170, and Fujirebio EIA. Passing-Bablok regression was used to compare automated assays to EIA and agreement between methods was estimated by Lin's concordance correlation coefficient (CCC). The bias vs. EIA was estimated and compared to specifications derived from HE4 biological variation. Median (25th-75th percentiles) HE4 concentrations (pmol/L) were 84.5 (60.1-148.8) for EIA, 82.7 (50.3-153.9) for Abbott, 89.1 (55.2-154.9) for Roche, and 112.2 (67.8-194.2) for Fujirebio. Estimated regressions and agreements (95% confidence interval) were: Abbott=1.01(0.98-1.03) EIA-4.8(-7.5/-2.6), CCC=0.99(0.99-1.00); Roche=0.91(0.89-0.93) EIA+5.7(4.2/8.0), CCC=0.98(0.98-0.99); Fujirebio=1.20(1.17-1.24) EIA+ 2.4(-0.6/4.9), CCC=0.97(0.96-0.98). The average bias vs. EIA resulted within the desirable goal for Abbott [-3.3% (-6.1/-0.5)] and Roche [-0.2% (-3.0/2.5)]. However, while for Abbott the bias was constant and acceptable along the measurement concentration range, Roche bias increased up to -28% for HE4 values >250 pmol/L. Lumipulse showed a markedly positive bias [25.3% (21.8/28.8)]. Abbott and Roche assays exhibited a good comparability in the range of HE4 values around the previously recommended 140 pmol/L cut-off. For patient monitoring, however, the assay used for determining serial HE4 must not be changed as results from different systems in lower and higher concentration ranges can markedly differ.

  9. The Effect of a Single Bout of Surfing on Exercise-Induced Affect.

    PubMed

    Pittsinger, Ryan; Kress, Jeff; Crussemeyer, Jill

    2017-01-01

    Exercise-induced affect (EIA) has been well documented and is often composed of positive affect, negative affect, tranquility, and fatigue. Research on EIA has focused on mainstream sports such as running, walking, or cycling; however, no research has evaluated the influence of action sports participation in activities such surfing on EIA. The current study examined the effect of a single 30-min surfing bout on EIA in 107 adult volunteers. An additional purpose was if change in affect was similar based on surfing history, surfing frequency, and surfing skill level. To assess EIA, each participant completed the Physical Activity Affect Scale (PAAS) prior to and immediately following the 30-min surf session. Dependent t -tests were used to examine differences between pre- and post-test EIA. For the secondary purpose, a change score (PAAS posttest-PAAS pretest) was computed for each subscale. One-way ANOVAs were performed to determine differences among comparisons of surfing history, surfing frequency, and surfing skill level, and the change score for each of the 4 subscales. EIA was significantly altered by surfing, with significant improvements in positive affect and tranquility, and significant reductions in negative affect and fatigue. There were no significant differences among surfing history, surfing frequency, and surfing skill level, and positive affect, negative affect or tranquility. However, there were significant differences between fatigue and surfing history, surfing frequency, and surfing skill level. The results indicate that a single 30-min surfing bout may provide positive benefits for the participant. Implications for future surfing research and EIA are discussed.

  10. The Effect of a Single Bout of Surfing on Exercise-Induced Affect

    PubMed Central

    PITTSINGER, RYAN; KRESS, JEFF; CRUSSEMEYER, JILL

    2017-01-01

    Exercise-induced affect (EIA) has been well documented and is often composed of positive affect, negative affect, tranquility, and fatigue. Research on EIA has focused on mainstream sports such as running, walking, or cycling; however, no research has evaluated the influence of action sports participation in activities such surfing on EIA. The current study examined the effect of a single 30-min surfing bout on EIA in 107 adult volunteers. An additional purpose was if change in affect was similar based on surfing history, surfing frequency, and surfing skill level. To assess EIA, each participant completed the Physical Activity Affect Scale (PAAS) prior to and immediately following the 30-min surf session. Dependent t-tests were used to examine differences between pre- and post-test EIA. For the secondary purpose, a change score (PAAS posttest-PAAS pretest) was computed for each subscale. One-way ANOVAs were performed to determine differences among comparisons of surfing history, surfing frequency, and surfing skill level, and the change score for each of the 4 subscales. EIA was significantly altered by surfing, with significant improvements in positive affect and tranquility, and significant reductions in negative affect and fatigue. There were no significant differences among surfing history, surfing frequency, and surfing skill level, and positive affect, negative affect or tranquility. However, there were significant differences between fatigue and surfing history, surfing frequency, and surfing skill level. The results indicate that a single 30-min surfing bout may provide positive benefits for the participant. Implications for future surfing research and EIA are discussed. PMID:29170700

  11. Oil and gas field code master list 1994

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    This is the thirteenth annual edition of the Energy Information Administration`s (EIA) Oil and Gas Field Code Master List. It reflects data collected through October 1994 and provides standardized field name spellings and codes for all identified oil and/or gas fields in the United States. The master field name spellings and codes are to be used by respondents when filing the following Department of Energy (DOE) forms: Form EIA-23, {open_quotes}Annual Survey of Domestic Oil and Gas Reserves,{close_quotes} filed by oil and gas well operators (field codes are required from larger operators only); Forms FERC 8 and EIA-191, {open_quotes}Underground Gas Storagemore » Report,{close_quotes} filed by natural gas producers and distributors who operate underground natural gas storage facilities. Other Federal and State government agencies, as well as industry, use the EIA Oil and Gas Field Code Master List as the standard for field identification. A machine-readable version of the Oil and Gas Field Code Master List is available from the National Technical Information Service, 5285 Port Royal Road, Springfield, Virginia 22161, (703) 487-4650. In order for the Master List to be useful, it must be accurate and remain current. To accomplish this, EIA constantly reviews and revises this list. The EIA welcomes all comments, corrections, and additions to the Master List. All such information should be given to the EIA Field Code Coordinator at (214) 953-1858. EIA gratefully acknowledges the assistance provides by numerous State organizations and trade associations in verifying the existence of fields and their official nomenclature.« less

  12. Comparison of fifteen commercial assays for detecting Varicella Zoster virus IgG with reference to a time resolved fluorescence immunoassay (TRFIA) and the performance of two commercial assays for screening sera from immunocompromised individuals.

    PubMed

    Chris Maple, P A; Gunn, Annabel; Sellwood, Jane; Brown, David W G; Gray, Jim J

    2009-02-01

    The performance of fifteen, commercially available, VZV IgG assays and an "in house" indirect immunofluorescence (IF) assay has been compared to a reference VZV IgG time resolved immunofluorescence assay (VZV TRFIA). A panel of 273 VZV TRFIA IgG positive serum samples and 136 VZV TRFIA IgG susceptible sera, collected from a number of UK hospitals was used. Irrespective of the interpretation of equivocal results the most sensitive assays were Dade Behring EIA (97.4%), "in house" IF (95.2%), Human EIA (92.3%) and Becton Dickinson latex agglutination (94.1%). The least sensitive assays were Virion EIA (69.6%), Diesse EIA (68.9%) and Diasys EIA (68.5%). The least sensitive (<70%) assays all had >99.0% specificity whereas the most sensitive assays had lower specificities; for example, Dade Behring EIA had a specificity of 69.9% when equivocals were treated as VZV IgG negative. For some assays e.g. Dade Behring EIA there were major discrepancies between our findings and those reported by the manufacturer which may reflect the constitution of the panel(s) of sera used for evaluation or the reference method adopted or the choice of cut-off criteria (particularly relevant to our findings for the Behring EIA). Care must be taken to choose an assay with high specificity in order to accurately assess the need for vaccination or immunoprophylaxis; however, high sensitivity is preferable to prevent inappropriate and expensive treatment.

  13. 30 CFR 550.227 - What environmental impact analysis (EIA) information must accompany the EP?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... and Information Contents of Exploration Plans (ep) § 550.227 What environmental impact analysis (EIA... 30 Mineral Resources 2 2012-07-01 2012-07-01 false What environmental impact analysis (EIA) information must accompany the EP? 550.227 Section 550.227 Mineral Resources BUREAU OF OCEAN ENERGY MANAGEMENT...

  14. 30 CFR 550.227 - What environmental impact analysis (EIA) information must accompany the EP?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... and Information Contents of Exploration Plans (ep) § 550.227 What environmental impact analysis (EIA... 30 Mineral Resources 2 2013-07-01 2013-07-01 false What environmental impact analysis (EIA) information must accompany the EP? 550.227 Section 550.227 Mineral Resources BUREAU OF OCEAN ENERGY MANAGEMENT...

  15. 30 CFR 250.227 - What environmental impact analysis (EIA) information must accompany the EP?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... and Information Contents of Exploration Plans (ep) § 250.227 What environmental impact analysis (EIA... 30 Mineral Resources 2 2010-07-01 2010-07-01 false What environmental impact analysis (EIA) information must accompany the EP? 250.227 Section 250.227 Mineral Resources MINERALS MANAGEMENT SERVICE...

  16. 30 CFR 550.227 - What environmental impact analysis (EIA) information must accompany the EP?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... and Information Contents of Exploration Plans (ep) § 550.227 What environmental impact analysis (EIA... 30 Mineral Resources 2 2014-07-01 2014-07-01 false What environmental impact analysis (EIA) information must accompany the EP? 550.227 Section 550.227 Mineral Resources BUREAU OF OCEAN ENERGY MANAGEMENT...

  17. 30 CFR 250.261 - What environmental impact analysis (EIA) information must accompany the DPP or DOCD?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Operations Coordination Documents (docd) § 250.261 What environmental impact analysis (EIA) information must... 30 Mineral Resources 2 2010-07-01 2010-07-01 false What environmental impact analysis (EIA) information must accompany the DPP or DOCD? 250.261 Section 250.261 Mineral Resources MINERALS MANAGEMENT...

  18. 78 FR 15712 - Agency Information Collection Activities: Submission for OMB Review; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-12

    ... Request. SUMMARY: The EIA has submitted the Financial Reporting EIA-28 Survey package to the Office of... Financial Reporting System, Form EIA-28 collects data used to analyze the energy industry's competitive.... This is a request to conduct a comprehensive voluntary evaluation of an existing data collection to...

  19. A comparison of an immunological faecal occult blood test Fecatwin sensitive/FECA EIA with Haemoccult in population screening for colorectal cancer.

    PubMed Central

    Armitage, N.; Hardcastle, J. D.; Amar, S. S.; Balfour, T. W.; Haynes, J.; James, P. D.

    1985-01-01

    Two faecal occult blood tests, a simple chemical test Haemoccult and an immunological test, Fecatwin Sensitive/Feca EIA, were offered to 3,225 asymptomatic individuals as screening for colorectal cancer. One thousand three hundred and four (44%) completed and returned the tests and of these 126 (9.7%) were found to be positive - Haemoccult 40 (3%) and Feca EIA 106 (8.1%). Five cancers (4 Dukes' Stage A, 1 Dukes' Stage C) and 23 adenomas greater than 1 cm were detected - rates of 3.8 per 1000 persons screened and 17.7 per 1000 persons screened respectively. Of the five cancers identified 5 were Feca EIA positive and 3 were Haemoccult positive. Of the 23 adenomas greater than 1 cm diameter identified, J1 were Feca EIA positive and 20 were Haemoccult positive. Seventy-eight Feca EIA positive subjects were investigated and no neoplastic disease was identified. Whilst this sensitive immunological test increases the yield of carcinomas, the high false positive rate makes it unsuitable for population screening for colorectal cancer in its present form. PMID:4005139

  20. Multi-jurisdictional environmental impact assessment: Canadian experiences

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fitzpatrick, Patricia, E-mail: p.fitzpatrick@uwinnipeg.c; Sinclair, A. John, E-mail: Jsincla@ms.umanitoba.c

    This research examines complexities surrounding environmental impact assessment (EIA) in a multi-jurisdictional environment, with a specific focus on opportunities for public participation. With almost universal adoption of EIA, projects are increasingly subject to more than one assessment process. Thus there is demand to facilitate inter-jurisdictional coordination of EIAs. Canada has growing expertise with multijuristictional EIA that serves to illustrate the costs and opportunities associated with three different approaches to coordination: standardization, harmonization and substitution. Findings suggest that, although fraught with issues, harmonization is the most realistic approach for coordinating efforts. Harmonization has the potential to minimize duplication, avoid process uncertaintymore » and increase efficiency and effectiveness in EIA. Furthermore, the analysis demonstrates that a bilateral agreement between jurisdictions is the best approach to harmonization, so long as negotiation of the agreement includes opportunities for meaningful participation, and implementation includes activities designed to communicate the assessment responsibilities of each jurisdiction, activities and schedules to the public. The experience of participants of different coordinated EIAs in Canada serves as counsel for on-going and future efforts to facilitate inter-jurisdictional coordination.« less

  1. Current legal regime for environmental impact assessment in areas beyond national jurisdiction and its future approaches

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ma, Deqiang; Coastal and Ocean Management Institute, Xiamen University, 361102; Fang, Qinhua, E-mail: qhfang@xmu.edu.cn

    In 2004, the United Nations launched an Ad Hoc Open-ended Informal Working Group to study issues relating to the conservation and sustainable use of marine biological diversity in areas beyond national jurisdiction. Since then, the topic of governing marine areas beyond national jurisdiction (ABNJ) has been widely discussed by politicians, policy makers and scholars. As one of management tools to protect marine biodiversity in ABNJ, environmental impact assessment (EIA) has been widely recognized and accepted by the international community, however, the biggest challenge is how to effectively implement the EIA regime in ABNJ. This paper explores the impacts of anthropogenicmore » activities in ABNJ on marine ecosystems, reviews the existing legal regime for EIA in ABNJ and discusses possible measures to strengthen the implementation of EIA in ABNJ. - Highlights: • We identify human activities in ABNJ and their impacts on marine ecosystems. • We analyze the characters and gaps of the existing legal regime for EIA in ABNJ. • We analyze the pros and cons of alternative approaches of EIA in ABNJ.« less

  2. Imaging with indium111-labeled anticarcinoembryonic antigen monoclonal antibody ZCE-025 of recurrent colorectal or carcinoembryonic antigen-producing cancer in patients with rising serum carcinoembryonic antigen levels and occult metastases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Patt, Y.Z.; Lamki, L.M.; Shanken, J.

    1990-07-01

    We tested whether nuclear imaging with indium111 (111In)-labeled murine monoclonal (MoAb) anticarcinoembryonic antigen (anti-CEA) ZCE-025 antibody could detect recurrent disease in patients with a rising serum CEA level but negative findings for computed tomographic (CT) scans of the abdomen and pelvis, chest radiograph, and colonoscopy or barium enema. Twenty patients with a history of completely resected CEA-producing adenocarcinoma and a rising serum CEA level were given an intravenous infusion of 2 mg of 111In-labeled ZCE-025 mixed with 38 mg of unlabeled ZCE-025. Planar and single-photon emission CT (SPECT) scans were acquired at 72 and 144 hours, and in 19 ofmore » the 20 patients these were positive. Of those 19, 13 underwent exploratory surgery, and cancer was found in 10, and two had a diagnostic biopsy, which confirmed cancer. Three patients who had negative laparotomies and all four patients who did not undergo surgery or biopsy were followed radiologically. In all seven, cancer was subsequently detected at the sites suggested by the ZCE-025 scan. Thus, tumor was confirmed in all 19 patients with positive scans. Five of 13 patients who were explored benefited from the study and the exploratory laparotomy, as disease was entirely resected in four or was subjected to definitive radiation therapy to the pelvis in the fifth. In two additional patients who were not explored, MoAb imaging resulted in definitive therapy to regionally confined recurrent disease. 111In-labeled anti-CEA MoAb ZCE-025 scanning in patients with rising CEA successfully imaged metastatic colorectal cancer that eluded detection by other methods and affected the care given to some. These results suggest an important role for 111In-labeled ZCE-025 scanning among patients with rising CEA and otherwise occult metastatic cancer.« less

  3. Observation of EIA in closed and open caesium atomic system

    NASA Astrophysics Data System (ADS)

    Zhao, Jian-Ming; Zhao, Yan-Ting; Huang, Tao; Xiao, Lian-Tuan; Jia, Suo-Tang

    2005-04-01

    We present an experimental study on electromagnetically induced absorption (EIA) in the closed transition of a degenerate two-level Cs atomic system. The coupling and probe lasers coupled with the transition 6S1/2F=4 → 6P3/2F'=5 of caesium atom. The signal of EIA was obtained and the frequency detuning and intensity effect of the pumping laser were experimentally investigated. The EIA signal in 6S1/2 F=4 → 6P3/2 F'=4 and 6S1/2 F=4 → 6P3/2 F'=3 open transitions was also obtained. As the repumping laser couples with the transition of 6S1/2 F=3 → 6P3/2 F'=4, the EIA signal is increased due to the hyperfine optical pumping.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Toro, Javier, E-mail: jjtoroca@unal.edu.c; Requena, Ignacio, E-mail: requena@decsai.ugr.e; Zamorano, Montserrat, E-mail: zamorano@ugr.e

    The evaluation of Environmental Impact Assessment (EIA) systems is a highly recommended strategy for enhancing their effectiveness and quality. This paper describes an evaluation of EIA in Colombia, using the model and the control mechanisms proposed and applied in other countries by Christopher Wood and Ortolano. The evaluation criteria used are based on Principles of Environmental Impact Assessment Best Practice, such as effectiveness and control features, and they were contrasted with the opinions of a panel of Colombian EIA experts as a means of validating the results of the study. The results found that EIA regulations in Colombia were ineffectivemore » because of limited scope, inadequate administrative support and the inexistence of effective control mechanisms and public participation. This analysis resulted in a series of recommendations regarding the further development of the EIA system in Colombia with a view to improving its quality and effectiveness.« less

  5. Androgen and androgen metabolite levels in serum and urine of East African chimpanzees (Pan troglodytes schweinfurthii): comparison of EIA and LC-MS analyses.

    PubMed

    Preis, Anna; Mugisha, Lawrence; Hauser, Barbara; Weltring, Anja; Deschner, Tobias

    2011-12-01

    The primary male androgen testosterone (T) is often used as an endocrinological marker to investigate androgen-behaviour interactions in males. In chimpanzees and bonobos, studies investigating the relationship between T levels and dominance rank or aggressive behaviour have revealed contradictory results. The immunoassays used in these studies were originally developed for the measurement of steroids in serum. Their application to non-invasively collected samples, however, can lead to methodological problems due to cross-reacting metabolites, which might occur in urine or faeces but not in blood. The overall aim of this study, therefore, is to clarify whether a T enzyme immunoassay (EIA) is an applicable method to monitor testicular function in adult male chimpanzees. To estimate the impact of cross-reacting androgens on the used T EIA, we compared the results of an EIA measurement with a set of androgen metabolite levels measured by LC-MS. In urine from male chimpanzees, cross-reactivities appear to exist mainly with T and its exclusive metabolites, 5α-dihydrotestosterone (5α-DHT) and 5α-androstanediol (androstanediol). Both urinary and serum T levels of male chimpanzees were significantly higher than female T levels when measured with the T EIA, indicating a reliable measurement of testicular androgens and their exclusive metabolites with the used EIA. In urine from female chimpanzees, the comparison between LC-MS and T EIA results indicated a higher impact of cross-reactions with adrenal androgen metabolites. Therefore, the investigation of urinary T levels in female chimpanzees with a T EIA seems to be problematic. Overall our results show that a T EIA can be a reliable method to monitor testicular function in male chimpanzee urine and that LC-MS is a valuable tool for the validation of immunoassays. Copyright © 2011 Elsevier Inc. All rights reserved.

  6. Reforming EIA systems: A critical review of proposals in Brazil

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fonseca, Alberto, E-mail: albertof@em.ufop.br; Sánchez, Luis Enrique; Ribeiro, José Claudio Junqueira

    Environmental Impact Assessment (EIA) systems are under pressure in many countries, driven by a call for efficiency and streamlining. Such a phenomenon is particularly clear in Brazil, where, in the past few years, a number of influential associations put forward documents proposing significant changes to environmental licensing and impact assessment regulations. So far, there is no publicly available information about any initiative towards scrutinizing those proposals. The objective of this study was to critically review the merits and drawbacks of the changes proposed in those documents. The analysis triangulated content analysis, focus group and online survey data. The focus groupmore » included ten seasoned Brazilian EIA specialists; the survey, based on Likert-scale and open-ended questions, resulted in 322 valid responses from EIA professionals. Results show that the proposals generally agree that the current EIA system, while playing a key role in mitigating impacts and enhancing project design, needs many changes. Nonetheless, the proposals neither offered solutions to overcome political, technical and budget barriers, nor established a sense of priority of the most urgent issues. Findings from the focus group and the survey signaled that a number of proposed actions might face public outcry, and that those changes that do not depend on legislative action are more likely to be implementable. Previous studies about EIA reform focused mostly on the context of developed countries after changes had taken place. This study, while addressing the perspective of a large developing country in a “before-reform” stage, shows that capacity-building is a key requirement in EIA reform. - Highlights: • Brazil's EIA system is under strong pressure for change. • Findings corroborate ineffectiveness in current system. • There are tensions as to the best approaches to overcome problems. • Exact effects of proposals are uncertain. • Low institutional capacity can play strong role in driving EIA reform.« less

  7. Comparison between two commercially available serological tests and polymerase chain reaction in the diagnosis of Cryptosporidium in animals and diarrhoeic children.

    PubMed

    Helmy, Yosra A; Krücken, Jürgen; Nöckler, Karsten; von Samson-Himmelstjerna, Georg; Zessin, Karl-H

    2014-01-01

    For the detection of Cryptosporidium species in 804 animals and 165 diarrhoeic children (<10 years) in Egypt, two copro-antigen tests, the RIDASCREEN® Cryptosporidium test [enzyme immunoassay (EIA)] and the RIDA®QUICK Cryptosporidium/Giardia Combi [immuno-chromatographic test (ICT)] as well as polymerase chain reaction (PCR) were used. Prevalence of Cryptosporidium was 15.0, 19.5 and 32.3% in animals and 2.4, 6.7 and 49.1% in children using EIA, ICT and PCR, respectively.Using PCR as reference method, animal samples sensitivity (Se) of the EIA was 46.5% when questionable samples were considered positive, whereas specificity (Sp) was 100%. Se of the ICT was 60.4% while Sp was 100%. Positive predictive values (PPVs) for both EIA and ICT test were 100%, and negative predictive values (NPVs) for EIA were 79.7 and 84.1% for ICT. For the children samples, the Se of EIA was 5%, Sp was 100%, PPV was 100% and NPV was 52.2%, while the Se of ICT was 13.6%, Sp was 100%, PPV was 100% and NPV was 54.6%.The Kappa score of agreement between PCR and ICT was 67.4%, 54.1% between PCR and EIA and 84.4% between ICT and EIA. Until the second serial dilution of the EIA and ICT test, 9 × 10(3) oocysts/μl of Cryptosporidia was detected, whereas in PCR, they were detected until the sixth serial dilution. Copro-antigen tests were easy to perform and less time-consuming but less sensitive compared to PCR. They obviously are best applicable for screening and epidemiological studies of large numbers of subjects, for batch specimen processing and in isolated or rural areas where reliable tests like PCR are unfeasible. When in children, a single stool sample is used for the diagnosis of clinical cases; better results can be obtained when non-standardized PCR due low specificity is coupled with copro-antigen tests.

  8. Regression Techniques for Determining the Effective Impervious Area in Southern California Watersheds

    NASA Astrophysics Data System (ADS)

    Sultana, R.; Mroczek, M.; Dallman, S.; Sengupta, A.; Stein, E. D.

    2016-12-01

    The portion of the Total Impervious Area (TIA) that is hydraulically connected to the storm drainage network is called the Effective Impervious Area (EIA). The remaining fraction of impervious area, called the non-effective impervious area, drains onto pervious surfaces which do not contribute to runoff for smaller events. Using the TIA instead of EIA in models and calculations can lead to overestimates of runoff volumes peak discharges and oversizing of drainage system since it is assumed all impervious areas produce urban runoff that is directly connected to storm drains. This makes EIA a better predictor of actual runoff from urban catchments for hydraulic design of storm drain systems and modeling non-point source pollution. Compared to TIA, determining the EIA is considerably more difficult to calculate since it cannot be found by using remote sensing techniques, readily available EIA datasets, or aerial imagery interpretation alone. For this study, EIA percentages were calculated by two successive regression methods for five watersheds (with areas of 8.38 - 158mi2) located in Southern California using rainfall-runoff event data for the years 2004 - 2007. Runoff generated from the smaller storm events are considered to be emanating only from the effective impervious areas. Therefore, larger events that were considered to have runoff from both impervious and pervious surfaces were successively removed in the regression methods using a criterion of (1) 1mm and (2) a max (2 , 1mm) above the regression line. MSE is calculated from actual runoff and runoff predicted by the regression. Analysis of standard deviations showed that criterion of max (2 , 1mm) better fit the regression line and is the preferred method in predicting the EIA percentage. The estimated EIAs have shown to be approximately 78% to 43% of the TIA which shows use of EIA instead of TIA can have significant impact on the cost building urban hydraulic systems and stormwater capture devices.

  9. EIA publications directory 1994

    NASA Astrophysics Data System (ADS)

    1995-07-01

    Enacted in 1977, the Department of Energy (DOE) Organization Act established the Energy Information Administration (EIA) as the Department's independent statistical and analytical agency, with a mandate to collect and publish data and prepare analyses on energy production, consumption, prices, resources, and projections of energy supply and demand. This edition of the EIA Publications Directory contains titles and abstracts of periodicals and one-time reports produced by EIA from January through December 1994. The body of the Directory contains citations and abstracts arranged by broad subject categories: metadata, coal, oil and gas, nuclear, electricity, renewable energy/alternative fuels, multifuel, end-use consumption, models, and forecasts.

  10. Effect of Submaximal Warm-up Exercise on Exercise-induced Asthma in African School Children.

    PubMed

    Mtshali, B F; Mokwena, K; Oguntibeju, O O

    2015-03-01

    Regular physical activity has long been regarded as an important component of a healthy lifestyle. Exercise-induced asthma (EIA) is one of the major problems interfering with the performance of exercise. A warm-up exercise programme has been cited as a non-pharmacologic means of reducing EIA, but its effect has not been fully elucidated. The aims of this study were to determine the prevalence of unrecognized EIA in Pretoria primary school children, determine the effect of a warm-up exercise programme on EIA and to establish the relationship between history of allergy, family history of asthma and EIA. A random sample of 640 school children was selected. The study was divided into three phases. In phase one, a descriptive cross-sectional study was done using the standardized European Community Respiratory Health Survey (ECRHS) questionnaire. In phase two, non-asthmatic participants that returned a completed questionnaire were included in the field study. Pre-test and post-test experimental designs were used, where peak expiratory flow rate (PEFR) was measured at baseline and within ten minutes after exercise. A total of 340 subjects completed the Free Running Asthma Screening Test (FRAST); EIA was defined as a decrease in baseline PEFR ≥ 10% after exercise and 75 children (22%) had EIA. In phase three, 29 of the 75 subjects participated in the warm-up programme which was performed in the laboratory and subjects acted as their own controls. Predefined protocols for the study were followed. Seventy-five (22%) of the 340 participants had EIA. The mean age, height and weight were 10.51 years, 139.26 cm and 33.45 kg, respectively. Exercise-induced asthma symptoms were cough (25%), chest pain (16%), wheeze (12%) and chest tightness (12%). The history of allergy was 75%, family history of allergy 40% and positive history of allergy when near animals, feathers or in dusty areas 38%. Wheezing during or after exercise, wheezing when near animals, feathers or in dusty areas and chest pain was significant (p < 0.05). The mean PEFR after exercise without warm-up was 4.43 L/min. The mean PEFR after exercise (warm-up) was 4.98. The mean percentage change in PEFR between exercise without warm-up and exercise with warm-up was 14.83%. The paired t-test showed a significant difference between PEFR with warm-up and PEFR without warm-up (p < 0.05). There was a high prevalence of EIA among study participants. Exercise-induced asthma symptoms were significant for wheezing and chest pain. Exercise after warm-up was significant in reducing EIA. This study reports the effect of warm-up exercise on EIA and highlights the need to screen school children for EIA.

  11. Imaging Lung Clearance of Radiolabeled Tumor Cells to Study Mice with Normal, Activated or Depleted Natural Killer (NK) Cells

    NASA Astrophysics Data System (ADS)

    Kulkarni, P. V.; Bennett, M.; Constantinescu, A.; Arora, V.; Viguet, M.; Antich, P.; Parkey, R. W.; Mathews, D.; Mason, R. P.; Oz, O. K.

    2003-08-01

    Lung clearance of 51CR and 125I iododeoxyuridine (IUDR) labeled cancer cells assess NK cell activity. It is desirable to develop noninvasive imaging technique to assess NK activity in mice. We labeled target YAC-1 tumor cells with 125I, 111In, 99mTc, or 67Ga and injected I.V. into three groups of BALB/c mice. Animals were treated with medium (group I), 300mg/kg cyclophosmamide (CY) to kill NK cell (group II), or anti-LY49C/1) (ab')2 mAb to augment NK function (group III). Lungs were removed 15 min or 2 h later for tissue counting. Control and treated mice were imaged every 5 min with a scintillating camera for 1 h after 15 min of infusion of the 111In labeled cells. Lung clearance increased after 15 min (lodging: 60-80%) and (2 h retention: 3-7%). Similar results were obtained with all the isotopes studied. Images distinguished the control and treated mice for lung activity. Cells labeled with 111In, 99mTc or 67Ga are cleared similar to those labeled with 51Cr or 125I. NK cell destruction of tumor cells may be assessed by noninvasive imaging method either by SPECT (99mTc, 111In, 67Ga) or by PET (68Ga).

  12. The sandwich-type electrochemiluminescence immunosensor for α-fetoprotein based on enrichment by Fe3O4-Au magnetic nano probes and signal amplification by CdS-Au composite nanoparticles labeled anti-AFP.

    PubMed

    Zhou, Hankun; Gan, Ning; Li, Tianhua; Cao, Yuting; Zeng, Saolin; Zheng, Lei; Guo, Zhiyong

    2012-10-09

    A novel and sensitive sandwich-type electrochemiluminescence (ECL) immunosensor was fabricated on a glassy carbon electrode (GCE) for ultra trace levels of α-fetoprotein (AFP) based on sandwich immunoreaction strategy by enrichment using magnetic capture probes and quantum dots coated with Au shell (CdS-Au) as the signal tag. The capture probe was prepared by immobilizing the primary antibody of AFP (Ab1) on the core/shell Fe(3)O(4)-Au nanoparticles, which was first employed to capture AFP antigens to form Fe(3)O(4)-Au/Ab1/AFP complex from the serum after incubation. The product can be separated from the background solution through the magnetic separation. Then the CdS-Au labeled secondary antibody (Ab2) as signal tag (CdS-Au/Ab2) was conjugated successfully with Fe(3)O(4)-Au/Ab1/AFP complex to form a sandwich-type immunocomplex (Fe(3)O(4)-Au/Ab1/AFP/Ab2/CdS-Au), which can be further separated by an external magnetic field and produce ECL signals at a fixed voltage. The signal was proportional to a certain concentration range of AFP for quantification. Thus, an easy-to-use immunosensor with magnetic probes and a quantum dots signal tag was obtained. The immunosensor performed at a level of high sensitivity and a broad concentration range for AFP between 0.0005 and 5.0 ng mL(-1) with a detection limit of 0.2 pg mL(-1). The use of magnetic probes was combined with pre-concentration and separation for trace levels of tumor markers in the serum. Due to the amplification of the signal tag, the immunosensor is highly sensitive, which can offer great promise for rapid, simple, selective and cost-effective detection of effective biomonitoring for clinical application. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. Localized Irradiation of Cell Membrane by Auger Electrons Is Cytotoxic Through Oxidative Stress-Mediated Nontargeted Effects.

    PubMed

    Paillas, Salomé; Ladjohounlou, Riad; Lozza, Catherine; Pichard, Alexandre; Boudousq, Vincent; Jarlier, Marta; Sevestre, Samuel; Le Blay, Marion; Deshayes, Emmanuel; Sosabowski, Jane; Chardès, Thierry; Navarro-Teulon, Isabelle; Mairs, Robert J; Pouget, Jean-Pierre

    2016-09-10

    We investigated whether radiation-induced nontargeted effects are involved in the cytotoxic effects of anticell surface monoclonal antibodies labeled with Auger electron emitters, such as iodine 125 (monoclonal antibodies labeled with (125)I [(125)I-mAbs]). We showed that the cytotoxicity of (125)I-mAbs targeting the cell membrane of p53(+/+) HCT116 colon cancer cells is mainly due to nontargeted effects. Targeted and nontargeted cytotoxicities were inhibited in vitro following lipid raft disruption with Methyl-β-cyclodextrin (MBCD) or filipin or use of radical oxygen species scavengers. (125)I-mAb efficacy was associated with acid sphingomyelinase activation and modulated through activation of the AKT, extracellular signal-related kinase ½ (ERK1/2), p38 kinase, c-Jun N-terminal kinase (JNK) signaling pathways, and also of phospholipase C-γ (PLC-γ), proline-rich tyrosine kinase 2 (PYK-2), and paxillin, involved in Ca(2+) fluxes. Moreover, the nontargeted response induced by directing 5-[(125)I]iodo-2'-deoxyuridine to the nucleus was comparable to that of (125)I-mAb against cell surface receptors. In vivo, we found that the statistical significance of tumor growth delay induced by (125)I-mAb was removed after MBCD treatment and observed oxidative DNA damage beyond the expected Auger electron range. These results suggest the involvement of nontargeted effects in vivo also. Low-energy Auger electrons, such as those emitted by (125)I, have a short tissue range and are usually targeted to the nucleus to maximize their cytotoxicity. In this study, we show that targeting the cancer cell surface with (125)I-mAbs produces a lipid raft-mediated nontargeted response that compensates for the inferior efficacy of non-nuclear targeting. Our findings describe the mechanisms involved in the efficacy of (125)I-mAbs targeting the cancer cell surface. Antioxid. Redox Signal. 25, 467-484.

  14. Localized Irradiation of Cell Membrane by Auger Electrons Is Cytotoxic Through Oxidative Stress-Mediated Nontargeted Effects

    PubMed Central

    Paillas, Salomé; Ladjohounlou, Riad; Lozza, Catherine; Pichard, Alexandre; Boudousq, Vincent; Jarlier, Marta; Sevestre, Samuel; Le Blay, Marion; Deshayes, Emmanuel; Sosabowski, Jane; Chardès, Thierry; Navarro-Teulon, Isabelle; Mairs, Robert J.

    2016-01-01

    Abstract Aims: We investigated whether radiation-induced nontargeted effects are involved in the cytotoxic effects of anticell surface monoclonal antibodies labeled with Auger electron emitters, such as iodine 125 (monoclonal antibodies labeled with 125I [125I-mAbs]). Results: We showed that the cytotoxicity of 125I-mAbs targeting the cell membrane of p53+/+ HCT116 colon cancer cells is mainly due to nontargeted effects. Targeted and nontargeted cytotoxicities were inhibited in vitro following lipid raft disruption with Methyl-β-cyclodextrin (MBCD) or filipin or use of radical oxygen species scavengers. 125I-mAb efficacy was associated with acid sphingomyelinase activation and modulated through activation of the AKT, extracellular signal-related kinase ½ (ERK1/2), p38 kinase, c-Jun N-terminal kinase (JNK) signaling pathways, and also of phospholipase C-γ (PLC-γ), proline-rich tyrosine kinase 2 (PYK-2), and paxillin, involved in Ca2+ fluxes. Moreover, the nontargeted response induced by directing 5-[(125)I]iodo-2′-deoxyuridine to the nucleus was comparable to that of 125I-mAb against cell surface receptors. In vivo, we found that the statistical significance of tumor growth delay induced by 125I-mAb was removed after MBCD treatment and observed oxidative DNA damage beyond the expected Auger electron range. These results suggest the involvement of nontargeted effects in vivo also. Innovation: Low-energy Auger electrons, such as those emitted by 125I, have a short tissue range and are usually targeted to the nucleus to maximize their cytotoxicity. In this study, we show that targeting the cancer cell surface with 125I-mAbs produces a lipid raft-mediated nontargeted response that compensates for the inferior efficacy of non-nuclear targeting. Conclusion: Our findings describe the mechanisms involved in the efficacy of 125I-mAbs targeting the cancer cell surface. Antioxid. Redox Signal. 25, 467–484. PMID:27224059

  15. Comparison of Natural Gas Storage Estimates from the EIA and AGA

    EIA Publications

    1997-01-01

    The Energy Information Administration (EIA) has been publishing monthly storage information for years. In order to address the need for more timely information, in 1994 the American Gas Association (AGA) began publishing weekly storage levels. Both the EIA and the AGA series provide estimates of the total working gas in storage, but use significantly different methodologies.

  16. EIA responds to Nature article on shale gas projections

    EIA Publications

    2014-01-01

    EIA has responded to a December 4, 2014 Nature article on projections of shale gas production made by EIA and by the Bureau of Economic Geology of the University of Texas at Austin (BEG/UT) with a letter to the editors of Nature. BEG/UT has also responded to the article in their own letter to the editor.

  17. 30 CFR 550.261 - What environmental impact analysis (EIA) information must accompany the DPP or DOCD?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Operations Coordination Documents (docd) § 550.261 What environmental impact analysis (EIA) information must... 30 Mineral Resources 2 2013-07-01 2013-07-01 false What environmental impact analysis (EIA) information must accompany the DPP or DOCD? 550.261 Section 550.261 Mineral Resources BUREAU OF OCEAN ENERGY...

  18. 30 CFR 550.261 - What environmental impact analysis (EIA) information must accompany the DPP or DOCD?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Operations Coordination Documents (docd) § 550.261 What environmental impact analysis (EIA) information must... 30 Mineral Resources 2 2012-07-01 2012-07-01 false What environmental impact analysis (EIA) information must accompany the DPP or DOCD? 550.261 Section 550.261 Mineral Resources BUREAU OF OCEAN ENERGY...

  19. 30 CFR 550.261 - What environmental impact analysis (EIA) information must accompany the DPP or DOCD?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Operations Coordination Documents (docd) § 550.261 What environmental impact analysis (EIA) information must... 30 Mineral Resources 2 2014-07-01 2014-07-01 false What environmental impact analysis (EIA) information must accompany the DPP or DOCD? 550.261 Section 550.261 Mineral Resources BUREAU OF OCEAN ENERGY...

  20. [What EIA assay levels correspond to rubella antibody HI assay titer?].

    PubMed

    Terada, Kihei; Inoue, Mika; Wakabayashi, Tokio; Ogita, Satoko; Ouchi, Kazunobu

    2009-01-01

    In 2004, a Japanese-government-supported research group recommended that women without rubella antibody or with low titers < or = 1:16 of HI antibody should be vaccinated to decrease the risk of congenital rubella syndrome. We compared HI antibody titer with EIA-IgG levels in 520 college students with < or = 1:64, HI antibody measuring rubella antibodies in the same specimen using HI and EIA assay kits from Denka Seiken Co. (Japan) and Dade Behring Co. (Germany). The positive predictive value of the EIA assay using the kit from Denka Seiken Co. was 99.8% and the negative predictive value 91.3%, respectively, compared to 97.9% (positive > or = 15 IU/mL), 98.1% (positive > or = 10 IU/mL), and 93.4%, using the kit from Dade Behring Co. Between HI titers and EIA-IgG measured with the Denka kit, the coefficient index was 0.715 (p < 0.0001). Between those measured with the Dade kit, the coefficient index was 0.610 (p < 0.0001). Between EIA-IgG levels measured using the two kits, the coefficient index was 0.753 (p < 0.0001). The HI value of 1:16 corresponds approximately to 9.0 with the kit (positive > or = 4.0) from Denka, and to 30 IU/mL with the kit from Dade. EIA-IgG levels > or = 10 IU/mL are considered globally as protective antibody titers, meaning that the Japanese recommendation of < or = 1:16 for vaccination is too loose. Japanese EIA kit values for the rubella antibody should also be expressed in IU/mL using the global standard.

  1. The assessment of aesthetic and perceptual aspects within environmental impact assessment of renewable energy projects in Italy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tolli, Michela, E-mail: michela.tolli@uniroma1.it; Recanatesi, Fabio, E-mail: fabio.rec@unitus.it; Piccinno, Matteo

    The main aim of this paper is to explore how perceptual and aesthetic impact analyses are considered in Environmental Impact Assessment (EIA), with specific reference to Italian renewable energy projects. To investigate this topic, the paper starts by establishing which factors are linked with perceptual and aesthetic impacts and why it is important to analyze these aspects, which are also related to legislative provisions and procedures in Europe and in Italy. In particular the paper refers to renewable energy projects because environmental policies are encouraging more and more investment in this kind of primary resource. The growing interest in thismore » type of energy is leading to the realization of projects which change the governance of territories, with inevitable effects on the landscape from the aesthetic and perceptual points of view. Legislative references to EIA, including the latest directive regarding this topic show the importance of integrating the assessment of environmental and perceptual impacts, thus there is a need to improve EIA methodological approaches to this purpose. This paper proposes a profile of aesthetic and perceptual impact analysis in EIA for renewable energy projects in Italy, and concludes with recommendations as to how this kind of analysis could be improved. - Highlights: • We analyze 29 EIA Reports of Italian renewable energy projects. • We examine esthetic and perceptual aspects present in Italian EIA reports. • We identified inconsistency in use of methods for esthetic and perceptual aspects. • Local populations are rarely included as stakeholders in EIAs. • A shared understanding of perceptual and esthetic issues in EIA proceedings is required.« less

  2. Phase 1 trial of irinotecan plus BCNU in patients with progressive or recurrent malignant glioma1

    PubMed Central

    Quinn, Jennifer A.; Reardon, David A.; Friedman, Allan H.; Rich, Jeremy N.; Sampson, John H.; Vredenburgh, James; Gururangan, Sridharan; Provenzale, James M.; Walker, Amy; Schweitzer, Holly; Bigner, Darell D.; Tourt-Uhlig, Sandra; Herndon, James E.; Affronti, Mary Lou; Jackson, Susanne; Allen, Deborah; Ziegler, Karen; Bohlin, Cindy; Lentz, Christy; Friedman, Henry S.

    2004-01-01

    Irinotecan is a topoisomerase I inhibitor previously shown to be active in the treatment of malignant glioma. We now report the results of a phase 1 trial of irinotecan plus BCNU, or 1,3-bis(2-chloroethyl)-1-nitrosourea, for patients with recurrent or progressive MG. Irinotecan dose escalation occurred independently within 2 strata: patients receiving enzyme-inducing antiepileptic drugs (EIAEDs) and patients not receiving EIAEDs. BCNU was administered at a dose of 100 mg/m2 over 1 h every 6 weeks on the same day as the first irinotecan dose was administered. Irinotecan was administered intravenously over 90 min once weekly. Treatment cycles consisted of 4 weekly administrations of irinotecan followed by a 2-week rest with dose escalation in cohorts of 3 to 6 patients. Seventy-three patients were treated, including 49 patients who were on EIAEDs and 24 who were not on EIAEDs. The maximum tolerated dose for patients not on EIAEDs was 125 mg/m2. The maximum tolerated dose for patients on EIAEDs was 225 mg/m2. Dose-limiting toxicity was evenly distributed among the following organ systems: pulmonary, gastrointestinal, cardiovascular, neurologic, infectious, and hematologic, without a clear predominance of toxicity involving any one organ system. There was no evidence of increasing incidence of toxicity involving one organ system as irinotecan dose was escalated. On the basis of these results, we conclude that the recommended doses of irinotecan for a phase 2 clinical trial when given in combination with BCNU (100 mg/m2) are 225 mg/m2 for patients on EIAEDs and 125 mg/m2 for patients not on EIAEDs. PMID:15134629

  3. Measurement of Antinuclear Antibodies: Assessment of Different Test Systems

    PubMed Central

    Kern, P.; Kron, M.; Hiesche, K.

    2000-01-01

    The performance of rat liver and HEp-2 in the detection of antinuclear antibodies (ANA) was studied by two independent sites and compared against an ANA enzyme immunoassay (EIA) screen and EIA systems for the measurement of antibodies to double-stranded DNA (dsDNA) and ENA. Sixty-two sera from patients with connective tissue disease (CTD) and 398 from controls suffering from other disorders were included. The level of agreement was, for HEp-2 and rat liver (within one site), 82.0% (ANA positive/ANA negative) and 51.0% (ANA pattern); and for HEp2- and HEp-2 (between sites), 71.8 and 86.5%. On sera with the ANA homogeneous pattern, the measurement of anti-ENA EIA added little to the detection rate with anti-dsDNA EIA alone. On ANA speckled sera, the EIA reactivity depended on the reaction of the mitotic cells: while sera with positive mitoses reacted similarly to ANA homogeneous sera, in those with negative mitoses the measurement of anti-ENA added about 10% to the detection rate achieved with anti-dsDNA alone. The measurement of anti-Scl-70 and anti-Jo-1 did not markedly improve the positive rate with classical ENA (anti-SSA, -SSB, -Sm, and -RNP) alone, raising doubts about the cost efficiency of including these measurements in unselected sera. The ANA EIA identified patients with CTD at a rate similar to that for rat liver and HEp-2. However, up to 98% of the sera found to be negative by ANA EIA but positive by use of rat liver and HEp-2 were from controls. Thus, the ANA EIA may possible be used as an alternative screen, particularly in laboratories with a high frequency of sera from patients not suffering from CTD. PMID:10618281

  4. Salient features of the dayside low latitude ionospheric response to the main phase step-I of the 17 March 2015 geomagnetic storm

    NASA Astrophysics Data System (ADS)

    Bagiya, Mala S.; Sunil, A. S.; Chakrabarty, D.; Sunda, Surendra

    2017-10-01

    Based on TEC observations by India's GPS Aided GEO Augmented Navigation (GAGAN) GPS network, we report the dayside low latitude ionospheric variations over the Indian region during the moderate main phase step-I of the 17 March 2015 geomagnetic storm. In addition, we assess the efficacy of GPS inferred TEC maps by International GNSS service (IGS) in capturing large scale diurnal features of equatorial ionization anomaly (EIA) over the Indian region during this period. Following the prompt penetration electric field (PPE) at ∼0605 UT, equatorial electrojet (EEJ) enhances by ∼55 nT over 75 ± 3oE longitudes where main phase step-I is coincided with local noon. Initial moderate EIA gradually strengthens with the storm commencement. Although GAGAN TEC exhibits more intense EIA evolution compare to IGS TEC maps, latitudinal extent of EIA are comparable in both. The enhanced EEJ reverses by ∼0918 UT under the effect of overshielding electric field, the later is accompanied by northward turning of interplanetary magnetic field (IMF) Bz. The weakening of well evolved EIA reflects in IGS TEC maps after ∼45 min of the overshielding occurrence. In contrary, GAGAN TEC shows the corresponding feature after ∼0115 h. Resurgence of EIA, following the PPE ∼1115 UT, shows up in GAGAN TEC but IGS TEC maps fails in capturing this feature. The observed low latitude TEC variations and EIA modulations are explained in terms of the varying storm time disturbance electric fields. The anomalies between the GAGAN TEC and IGS TEC maps are discussed in terms of the possible limitations of the IGS TEC maps in capturing storm time EIA variability over the Indian region.

  5. A novel acute HIV infection staging system based on 4th generation immunoassay.

    PubMed

    Ananworanich, Jintanat; Fletcher, James L K; Pinyakorn, Suteeraporn; van Griensven, Frits; Vandergeeten, Claire; Schuetz, Alexandra; Pankam, Tippawan; Trichavaroj, Rapee; Akapirat, Siriwat; Chomchey, Nitiya; Phanuphak, Praphan; Chomont, Nicolas; Michael, Nelson L; Kim, Jerome H; de Souza, Mark

    2013-05-29

    Fourth generation (4thG) immunoassay (IA) is becoming the standard HIV screening method but was not available when the Fiebig acute HIV infection (AHI) staging system was proposed. Here we evaluated AHI staging based on a 4thG IA (4thG staging). Screening for AHI was performed in real-time by pooled nucleic acid testing (NAT, n=48,828 samples) and sequential enzyme immunoassay (EIA, n=3,939 samples) identifying 63 subjects with non-reactive 2nd generation EIA (Fiebig stages I (n=25), II (n=7), III (n=29), IV (n=2)). The majority of samples tested (n=53) were subtype CRF_01AE (77%). NAT+ subjects were re-staged into three 4thG stages: stage 1 (n=20; 4th gen EIA-, 3rd gen EIA-), stage 2 (n=12; 4th gen EIA+, 3rd gen EIA-), stage 3 (n=31; 4th gen EIA+, 3rd gen EIA+, Western blot-/indeterminate). 4thG staging distinguishes groups of AHI subjects by time since presumed HIV exposure, pattern of CD8+ T, B and natural killer cell absolute numbers, and HIV RNA and DNA levels. This staging system further stratified Fiebig I subjects: 18 subjects in 4thG stage 1 had lower HIV RNA and DNA levels than 7 subjects in 4thG stage 2. Using 4th generation IA as part of AHI staging distinguishes groups of patients by time since exposure to HIV, lymphocyte numbers and HIV viral burden. It identifies two groups of Fiebig stage I subjects who display different levels of HIV RNA and DNA, which may have implication for HIV cure. 4th generation IA should be incorporated into AHI staging systems.

  6. Evaluation of a malarial antibody assay for use in the screening of blood and tissue products for clinical use.

    PubMed

    Kitchen, A D; Lowe, P H J; Lalloo, K; Chiodini, P L

    2004-10-01

    A new recombinant Plasmodium antigen enzyme immunoassay (EIA) for the detection of malarial antibodies was evaluated for the screening of 'malaria-risk' blood and tissue donations. A total of 13,269 donor and patient samples were tested by both the EIA and the standard diagnostic antibody immunofluorescence test (IFAT). A total of 114/138 (82.6%) samples from patients with P. falciparum and 11/13 (84.6%) samples from patients with P. vivax tested positive. A total of 714/13,053 (5.47%) samples from donors identified as 'malaria risk', owing to residency or travel, were reactive in the EIA. The assay is more sensitive than a previously implemented malarial antibody EIA (73% in acute P. falciparum and 56% in acute P. vivax infections). The sensitivity of this new EIA is comparable to that of the IFAT, and the specificity is sufficient to screen 'malaria-risk' donors.

  7. Benchmarking performance: Environmental impact statements in Egypt

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Badr, El-Sayed A., E-mail: ebadr@mans.edu.e; Zahran, Ashraf A., E-mail: ashraf_zahran@yahoo.co; Cashmore, Matthew, E-mail: m.cashmore@uea.ac.u

    Environmental impact assessment (EIA) was formally introduced in Egypt in 1994. This short paper evaluates 'how well' the EIA process is working in practice in Egypt, by reviewing the quality of 45 environmental impact statements (EISs) produced between 2000 and 2007 for a variety of project types. The Lee and Colley review package was used to assess the quality of the selected EISs. About 69% of the EISs sampled were found to be of a satisfactory quality. An assessment of the performance of different elements of the EIA process indicates that descriptive tasks tend to be performed better than scientificmore » tasks. The quality of core elements of EIA (e.g., impact prediction, significance evaluation, scoping and consideration of alternatives) appears to be particularly problematic. Variables that influence the quality of EISs are identified and a number of broad recommendations are made for improving the effectiveness of the EIA system.« less

  8. Ultra-narrow EIA spectra of 85Rb atom in a degenerate Zeeman multiplet system

    NASA Astrophysics Data System (ADS)

    Rehman, Hafeez Ur; Qureshi, Muhammad Mohsin; Noh, Heung-Ryoul; Kim, Jin-Tae

    2015-05-01

    Ultra-narrow EIA spectral features of thermal 85Rb atom with respect to coupling Rabi frequencies in a degenerate Zeeman multiplet system have been unraveled in the cases of same (σ+ -σ+ , π ∥ π) and orthogonal (σ+ -σ- , π ⊥ π)polarization configurations. The EIA signals with subnatural linewidth of ~ 100 kHz even in the cases of same circular and linear polarizations of coupling and probe laser have been obtained for the first time theoretically and experimentally. In weak coupling power limit of orthogonal polarization configurations, time-dependent transfer of coherence plays major role in the splitting of the EIA spectra while in strong coupling power, Mollow triplet-like mechanism due to strong power bring into broad split feature. The experimental ultra-narrow EIA features using one laser combined with an AOM match well with simulated spectra obtained by using generalized time-dependent optical Bloch equations.

  9. Global scale equatorial ionization anomaly (EIA) response to magnetospheric disturbances based on the May-June 1987 SUNDIAL-coordinated observations

    NASA Astrophysics Data System (ADS)

    Abdu, M. A.; Walker, G. O.; Reddy, B. M.; de Paula, E. R.; Sobral, J. H. A.; Fejer, B. G.

    1993-07-01

    Equatorial ionization anomaly (EIA) responses to magnetospheric disturbances have been investigated using ionosonde and geomagnetic data sets obtained for different longitude sectors during the 9-day (28 May-7 June) globally-coordinated SUNDIAL 87 campaign. Attention is focused on the EIA response features of the two magnetically most-disturbed days of the campaign window, 29 May and 6 June. Anomalous EIA inhibition and development were simultaneously observed at widely separated (American and Asian) longitude sectors, accompanied respectively by events of morning electrojet reversal and evening partial ring current development. A numerical model of the low-latitude ionosphere has been used to quantify the role that a disturbance electric field could play in the observed EIA response features. The implications of the results on the global low-latitude disturbance electric field pattern is discussed.

  10. Explaining EIA Crude Oil and Petroleum Product Price Data and Comparing with Other U.S. Government Data Sources, 2001 to 2010

    EIA Publications

    2012-01-01

    This article describes the sampling frames and basic data collection methods for petroleum price data reported by Energy Information Administration (EIA) and other Government agencies. In addition, it compares and contrasts annual average prices reported by EIA with comparable prices from the Bureau of Labor Statistics (BLS) CPI (Consumer Price Indexes) for the retail prices of residential No. 2 distillate, on-highway diesel fuel and motor gasoline (all grades.) Further, it compares refiner wholesale/resale prices for No. 2 fuel oil, No. 2 diesel fuel, motor gasoline (all grades,) kerosene-type jet fuel and residual fuel oil reported by EIA with comparable prices from the BLS PPI (Producer Price Index.) A discussion of the various crude oil prices and spot/futures prices published by EIA and other Government agencies is also included in the article.

  11. Human respiratory syncytial virus genomic and antigenic variants isolated in two hospitals during one epidemic, in Santiago, Chile.

    PubMed

    Luchsinger, Vivian; Noy, Andrea Elgueta; Avendaño, Luis F

    2008-07-01

    Human respiratory syncytial virus (HRSV) is a major cause of severe lower respiratory tract infection (LRI) in children. Distinct variants of the viruses have been described. The objective was to compare the antigenic and genetic variability of HRSV strains recovered from infants admitted to two hospitals during one epidemic in a big city. We analyzed nasopharyngeal aspirates from 201 infants admitted for LRI to two hospitals during 2002 in Santiago, Chile. The analyses were carried out using a panel of monoclonal antibodies against G glycoprotein epitopes (EIA) and RFLP for N and G genes. No differences in HRSV groups A/B and in N patterns distribution were observed among both hospitals. On the contrary, antigenic and genetic G patterns displayed a wide diversity of strains circulating during one epidemic, in one big city. RSV variability assessment depended rather on the tool used for analysis than on the geographical location.

  12. Antibody labeling with Remazol Brilliant Violet 5R, a vinylsulphonic reactive dye.

    PubMed

    Ferrari, Alejandro; Friedrich, Adrián; Weill, Federico; Wolman, Federico; Leoni, Juliana

    2013-01-01

    Colloidal gold is the first choice for labeling antibodies to be used in Point Of Care Testing. However, there are some recent reports on a family of textile dyes-named "reactive dyes"-being suitable for protein labeling. In the present article, protein labeling conditions were optimized for Remazol Brilliant Violet 5R, and the sensitivity of the labeled antibodies was assessed and compared with that of colloidal-gold labeled antibodies. Also, the accelerated stability was explored. Optimal conditions were pH 10.95, dye:Ab molar ratio of 264 and an incubation time of 132 min. Labeled antibodies were stable, and could be successfully used in a slot blot assay, detecting as low as 400 ng/mL. Therefore, the present work demonstrates that vinylsulphonic reactive dyes can be successfully used to label antibodies, and are excellent candidates for the construction of a new generation of Point of Care Testing kits.

  13. Enhancement of lateral flow immunoassay by alkaline phosphatase: a simple and highly sensitive test for potato virus X.

    PubMed

    Panferov, Vasily G; Safenkova, Irina V; Varitsev, Yury A; Zherdev, Anatoly V; Dzantiev, Boris B

    2017-12-06

    Alkaline phosphatase (ALP) was used as an amplification tool in lateral flow immunoassay (LFIA). Potato virus Х (PVX) was selected as a target analyte because of its high economic importance. Two conjugates of gold nanoparticles were applied, one with mouse monoclonal antibody against PVX and one with ALP-labeled antibody against mouse IgG. They were immobilized to two fiberglass membranes on the test strip for use in LFIA. After exposure to the sample, a substrate for ALP (5-bromo-4-chloro-3-indolyl phosphate/nitro blue tetrazolium) was dropped on the test strip. The insoluble dark-violet diformazan produced by ALP precipitated on the membrane and significantly increased the color intensity of the control and test zones. The limit of detection (0.3 ng mL -1 ) was 27 times lower than that of conventional LFIA for both buffer and potato leaf extracts. The ALP-enhanced LFIA does not require additional preparation procedures or washing steps and may be used by nontrained persons in resource-limited conditions. The new method of enhancement is highly promising and may lead to application for routine LFIA in different areas. Graphical abstract Two gold nanoparticles (GNP) conjugates were used - the first with monoclonal antibodies (mAb) (GNP-mAb); the second - alkaline phosphatase-labeled antibody against mAb (GNP-anti-mAb-ALP). The immuno complexes are captured by the polyclonal antibodies (pAb) in the test zone. Addition of the substrate solution (BCIP/NBT) results in the accumulation of the insoluble colored product and in a significance increase in color intensity.

  14. 75 FR 43823 - Safety Zone; He'eia Kea Small Boat Harbor, Kaneohe Bay, Oahu, HI

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-27

    ... DEPARTMENT OF HOMELAND SECURITY Coast Guard 33 CFR Part 165 [Docket No. USCG-2010-0458] RIN 1625-AA00 Safety Zone; He'eia Kea Small Boat Harbor, Kaneohe Bay, Oahu, HI AGENCY: Coast Guard, DHS. ACTION: Temporary Final Rule. SUMMARY: The Coast Guard is establishing a temporary safety zone in He'eia Kea Small...

  15. EIA--A Teacher Education Project in Bangladesh: An Analysis from Diversified Perspectives

    ERIC Educational Resources Information Center

    Karim, Abdul; Mohamed, Abdul Rashid; Rahman, Mohammad Mosiur

    2017-01-01

    English in Action (EIA) is an ongoing teacher education project which places mobile technology at the centre of its action. Most of the studies carried out focused on the changes EIA brought in teachers' classroom actions. Along with this, they also explored the classroom to observe whether the input given during training program is implemented in…

  16. The Free-Running Asthma Screening Test: An Approach to Screening for Exercise-Induced Asthma in Rural Alabama.

    ERIC Educational Resources Information Center

    Heaman, Doris J.; Estes, Jenny

    1997-01-01

    This study documented the prevalence of exercise-induced asthma (EIA) in rural elementary schools, examining the use of a free-running asthma screening test and peak expiratory flow-rate measurement for school screening. Results indicated that 5.7% of the students had EIA. Absenteeism and poverty were related to EIA. (SM)

  17. [Equine Infectious Anemia (EIA)].

    PubMed

    Kaiser, A; Meier, H P; Straub, R; Gerber, V

    2009-04-01

    Equine Infectious Anemia (EIA) is a reportable, eradicable epizootic disease caused by the equine lentivirus of the retrovirus family which affects equids only and occurs worldwide. The virus is transmitted by blood, mainly by sanguivorous insects. The main symptoms of the disease are pyrexia, apathy, loss of body condition and weight, anemia, edema and petechia. However, infected horses can also be inapparent carriers without any overt signs. The disease is diagnosed by serological tests like the Coggins test and ELISA tests. Presently, Switzerland is offi cially free from EIA. However, Switzerland is permanently at risk of introducing the virus as cases of EIA have recently been reported in different European countries.

  18. Performances of Four Helicobacter pylori Serological Detection Kits Using Stool Antigen Test as Gold Standard.

    PubMed

    Biranjia-Hurdoyal, Susheela D; Seetulsingh-Goorah, Sharmila P

    2016-01-01

    The aim was to determine the performances of four Helicobacter pylori serological detection kits in different target groups, using Amplified IDEIA™ Hp StAR™ as gold standard. Kits studied were Rapid Immunochromatoghraphic Hexagon, Helicoblot 2.1, an EIA IgG kit and EIA IgA kit. Stool and blood samples were collected from 162 apparently healthy participants (control) and 60 Type 2 diabetes mellitus (T2DM) patients. The performances of the four serological detection kits were found to be affected by gender, age, health status and ethnicity of the participants. In the control group, the Helicoblot 2.1 kit had the best performance (AUC = 0.85; p<0.05, accuracy = 86.4%), followed by EIA IgG (AUC = 0.75; p<0.05, accuracy = 75.2%). The Rapid Hexagon and EIA IgA kits had relatively poor performances. In the T2DM subgroup, the kits H2.1 and EIA IgG had best performances, with accuracies of 96.5% and 93.1% respectively. The performance of EIA IgG improved with adjustment of its cut-off value. The performances of the detection kits were affected by various factors which should be taken into consideration.

  19. Directory of Energy Information Administration Model Abstracts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1986-07-16

    This directory partially fulfills the requirements of Section 8c, of the documentation order, which states in part that: The Office of Statistical Standards will annually publish an EIA document based on the collected abstracts and the appendices. This report contains brief statements about each model's title, acronym, purpose, and status, followed by more detailed information on characteristics, uses, and requirements. Sources for additional information are identified. All models active through March 1985 are included. The main body of this directory is an alphabetical list of all active EIA models. Appendix A identifies major EIA modeling systems and the models withinmore » these systems, and Appendix B identifies active EIA models by type (basic, auxiliary, and developing). EIA also leases models developed by proprietary software vendors. Documentation for these proprietary models is the responsibility of the companies from which they are leased. EIA has recently leased models from Chase Econometrics, Inc., Data Resources, Inc. (DRI), the Oak Ridge National Laboratory (ORNL), and Wharton Econometric Forecasting Associates (WEFA). Leased models are not abstracted here. The directory is intended for the use of energy and energy-policy analysts in the public and private sectors.« less

  20. Laboratory and epidemiologic evaluation of an enzyme immunoassay for antibodies to HTLV-III

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ward, J.W.; Grindon, A.J.; Feorino, P.M.

    1986-07-18

    The enzyme immunoassays (EIAs) for antibody to human T-cell lymphotropic virus type III (HTLV-III) were rapidly adopted for screening donated blood and plasma. To evaluate the significance of a positive EIA reaction, test performance was examined in a blood bank screening program. Specimens were tested by EIA, Western blot assay, and HTLV-III/lymphadenopathy-associated virus (LAV) culture. The EIA was positive in 0.25% of 67 190 blood donations. Specimens were categorized and 57.3% had low (weak) reactivity, 12.7% had moderate reactivity, and 30.0% had high reactivity. Highly reactive specimens were strongly associated with a positive Western blot or culture (86.7%) in contrastmore » to moderately and weekly reactive specimens (1.9%). Twenty-five of 29 donors interviewed with a highly reactive EIA had risk factors for HTLV-III/LAV infection. Risk factors were not identified for 74 of 75 interviewed donors with specimens of lower reactivity. The minimum calculated specificity was 99.82%. The use of the HTLV-III EIA has virtually eliminated the use of blood and plasma for HTLV-III/LAV infected donors.« less

  1. Intensity dependence narrowing of electromagnetically induced absorption in a Doppler-broadened medium

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dimitrijevic, J.; Arsenovic, D.; Jelenkovic, B. M.

    In this paper, we present a theoretical model for studying the interaction between linearly polarized laser light and near-degenerated Zeeman sublevels for a multiple V-type atomic system of {sup 2}S{sub 1/2}F{sub g}=2{yields}{sup 2}P{sub 3/2}F{sub e}=3 transition in {sup 87}Rb. We have calculated the laser absorption in a Hanle configuration, as well as the amplitudes and the widths of electromagnetically induced absorption (EIA) in the range of laser intensities from 0.01 to 40 mW/cm{sup 2}. Our results, showing nonvanishing EIA amplitude, a nonmonotonic increase of the EIA width for the increase of laser intensity, and pronounced shape differences of the Hanlemore » EIA curves at different laser intensities, are in good agreement with recent experimental results. We have found that the EIA behaves differently than the electromagnetically induced transparency (EIT) as a function of the laser intensity. Both the amplitude and width of the EIA have narrow maximums at 1 to 2 mW/cm{sup 2}. We have shown the strong influence of Doppler broadening of atomic transition on Hanle resonances and have suggested the explanation of it.« less

  2. Simultaneous detection of imidacloprid and parathion by the dual-labeled time-resolved fluoroimmunoassay.

    PubMed

    Shi, Haiyan; Sheng, Enze; Feng, Lu; Zhou, Liangliang; Hua, Xiude; Wang, Minghua

    2015-10-01

    A highly sensitive direct dual-labeled time-resolved fluoroimmunoassay (TRFIA) to detect parathion and imidacloprid simultaneously in food and environmental matrices was developed. Europium (Eu(3+)) and samarium (Sm(3+)) were used as fluorescent labels by coupling separately with L1-Ab and A1P1-Ab. Under optimal assay conditions, the half-maximal inhibition concentration (IC50) and limit of detection (LOD, IC10) were 10.87 and 0.025 μg/L for parathion and 7.08 and 0.028 μg/L for imidacloprid, respectively. The cross-reactivities (CR) were negligible except for methyl-parathion (42.4 %) and imidaclothiz (103.4 %). The average recoveries of imidacloprid ranged from 78.9 to 104.2 % in water, soil, rice, tomato, and Chinese cabbage with a relative standard deviation (RSD) of 2.4 to 11.6 %, and those of parathion were from 81.5 to 110.9 % with the RSD of 3.2 to 10.5 %. The results of TRFIA for the authentic samples were validated by comparison with gas chromatography (GC) analyses, and satisfactory correlations (parathion: R (2) = 0.9918; imidacloprid: R (2) = 0.9908) were obtained. The results indicate that the dual-labeled TRFIA is convenient and reliable to detect parathion and imidacloprid simultaneously in food and environmental matrices.

  3. Hepatitis C Testing

    PubMed Central

    Rochlani, Maya; Lewis, Jessica H.; Ramsey, Glenn E.; Bontempo, Franklin A.; Shah, Gunjan; Bowman, Rebecca A.; van Thiel, David H.; Starzl, Thomas E.

    2010-01-01

    Plasma samples from 1,182 patients undergoing primary liver transplantation were tested for anti-hepatitis C (HCV) virus by two methods: Ortho HCV ELISA Test System (EIA) and Chiron RIBA HCV Test System (RIBA II). The EIA results, 0 or +, were recorded first, followed by RIBA results, N = negative, P = positive, or I = indeterminate. Concordant results—0N, + P, + I—were found in 1,076 (91%), and discordant results were found in 106 (9%). The EIA optical density did not relate to concordant or discordant results. Band patterns were described by stating the band position (1, 2, 3, or 4) and insetting a dash (−) if no band was visualized. Most + P samples fell into two patterns: 47% showed all four bands, pattern 1234, and 15% showed the two-band pattern, 34. When the EIA was negative, 0P, the opposite was seen: 8% showed the 1234 pattern and 81% showed the 34 pattern. There were 226 samples that formed bands (+ P, 149; 0P, 31; + I, 15; 0I, 31). The frequency of bands was as follows: 4, 32%; 3, 31%; 2, 19%; and 1, 18%. Band 2 and the EIA test detected antibodies to the same c100-3 fragment and showed 74% concordance. No explanation is apparent for the lower concordance rate here than that between the EIA test and bands 3 = 96% or 4 = 88%. The EIA and RIBA II tests, together with positive liver function tests and abnormal tissue pathologic findings, provide a basis for the diagnosis of HCV. PMID:1377442

  4. Public participation and environmental impact assessment: Purposes, implications, and lessons for public policy making

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    O'Faircheallaigh, Ciaran, E-mail: Ciaran.Ofaircheallaigh@griffith.edu.a

    In recent years the need to enhance public participation in Environmental Impact Assessment (EIA), and the efficacy of alternative mechanisms in achieving this goal, have been central themes in the EIA literature. The benefits of public participation are often taken for granted, and partly for this reason the underlying rationale for greater public participation is sometimes poorly articulated, making it more difficult to determine how to pursue it effectively. The reasons for seeking public participation are also highly diverse and not always mutually consistent. There has been limited analysis of the implications of different forms and degrees of public participationmore » for public decision making based on EIA, and little discussion of how experience with public participation in EIA relates to debates about participation in policy making generally. This paper distinguishes various purposes for public participation in EIA, and discusses their implications for decision making. It then draws on some general models of public participation in policy making to consider how approaches to participation in EIA can be interpreted and valued, and asks what EIA experience reveals about the utility of these models. It argues that the models pay insufficient attention to the interaction that can occur between different forms of public participation; and to the fact that public participation raises issues regarding control over decision making that are not subject to resolution, but must be managed through ongoing processes of negotiation.« less

  5. Seroepidemiologic Survey of Varicella-Zoster Virus in Korean Adults Using Glycoprotein Enzyme Immuno Assay and Fluorescent Antibody to Membrane Antigen Test

    PubMed Central

    Kim, Yun Hwa; Hwang, Ji Young; Lee, Kyung Min; Choi, Jin Hee; Lee, Tae Yoon; Choi, Jong Soo

    2011-01-01

    Background Herpes zoster (HZ) occurs mainly in the elderly and Korea is rapidly becoming an aging society. Therefore, it is important to know the immune status against varicella-zoster virus (VZV) in Korean adults to prevent the disease. Objective The aim of this study was to survey the immune status of Korean adults over 40 years of age against VZV. Methods Antibody titer was measured using a VaccZyme™ VZV glycoprotein enzyme immunoassay (gpEIA) (Binding Site, UK). Fluorescent antibody to membrane antigen (FAMA) test was performed to measure the seropositive rate. Results HZ incidence in the 214 adults enrolled in this study was 10.3%. The gpEIA geometric mean titer (GMT) was 490 mIU/ml and 90.2% of the subjects had a protective level of gpEIA antibody titer against varicella. The average gpEIA GMT of adults who previously had HZ was 1,122 mIU/ml, which was higher than the average gpEIA GMT of 457 mIU/ml in adults who had not had HZ. The FAMA positive rate was 98.6%. Conclusion Most (90.2%) Korean adults ≥40-years-of-age have a protective level of gpEIA antibody against varicella and 98.6% were FAMA seropositive. The GMT of gpEIA antibody was significantly increased with age, and was higher in adults with a history of HZ. PMID:21738361

  6. Consideration of climate change on environmental impact assessment in Spain

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Enríquez-de-Salamanca, Álvaro, E-mail: aenriquez@draba.org; Martín-Aranda, Rosa M., E-mail: rmartin@ccia.uned.es; Díaz-Sierra, Rubén, E-mail: sierra@dfmf.uned.es

    Most of the projects subject to environmental impact assessment (EIA) are closely related to climate change, as they contribute to or are affected by it. The growing certainty about climate change and its impacts makes its consideration an essential part of the EIA process, as well as in strategic environmental assessment (SEA). This paper examines how climate change (CC) has been taken into account in EIA in Spain through the analysis of 1713 environmental records of decision (RODs) of projects submitted for EIA. In 2013 Spain approved one of the most advanced laws in terms of CC consideration in environmentalmore » assessment, although it had not yet accumulated extensive practice on the issue. This contrasts with the situation of countries like Canada or the USA, which have a significant body of experience without specific legal requirements. Only 14% of the RODs analysed included references to CC, and in more than half of the cases it was a mere citation. Thermal power plants, which are subject to specific GHG regulations, show the highest consideration, while transport infrastructures, which are important contributors to CC, show a very low consideration. Almost all the references are related to their contribution to CC, while consideration of the effects of CC is minimal. The increasingly common incorporation of CC into SEA, should not imply its exclusion from EIA, because both processes have different aims and uses. Including the obligation to consider CC in the EIA regulations is highly desirable, but probably not enough without other measures, such as practical guidance, training and motivational programmes for practitioners and evaluators. But even these actions cannot ensure effective and adequate assessments of CC. Probably more resources should be spent on creating greater awareness in all the agents involved in EIA. - Highlights: • We analyse how the climate change is considered in EIA in Spain. • Few projects seriously assess climate change. • Transport infrastructure projects barely consider climate change. • Assessing climate change in SEA should not imply that it is excluded from EIA.« less

  7. Quality of Cultural Heritage in EIA; twenty years of experience in Norway

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lindblom, Inge, E-mail: inge.lindblom@niku.no

    2012-04-15

    The aim of this paper is to clarify and discuss how quality, relevance, attitudes, beliefs and transfer value act as underlying driving forces in the development of the Cultural Heritage theme in EIAs. One purpose is to identify and discuss some conditions that can better environmental assessment in order to increase the significance of EIA in decision-making with regard to Cultural Heritage. The main tools used are different research methods designed for analyses of quality and quality changes, primarily based on the relevant opinions of 160 people occupied with Cultural Heritage in EIA in Norway. The study is based onmore » a review of 40 types of EIAs from 1991 to 2000, an online questionnaire to 319 (160 responded) individuals from 14 different backgrounds, and interviews with three institutions in Sweden and Denmark. The study confirms a steadily increasing quality on EIRs over time, parallel with an improvement of the way in which Cultural Heritage is treated in EIA. This is supported by both the interviews and the qualitative comments regarding the survey. Potential for improvements is shown to be a need for more detailed background material as well as more use of adequate methods. The survey shows the existence of a wide variety of negative views, attitudes and beliefs, but the consequences of this are difficult to evaluate. However, most certainly, negative attitudes and beliefs have not been powerful enough to be detrimental to the quality of Cultural Heritage component, as nothing in the study indicates that negative attitudes and myths are undermining the system of EIA. The study shows the importance of having on-going discussions on quality and quality change over time by people involved in EIA, and how this is a necessary condition for successful implementation and acceptance. Beliefs and negative attitudes can also be a catalyst for developing better practice and advancing new methodology. In addition, new EIA countries must be prepared for several years of development and improvements after implementation. This is important in order to gain acceptance from the bureaucracy, especially from the Cultural Heritage authorities and local population.« less

  8. Appraising the value of independent EIA follow-up verifiers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wessels, Jan-Albert, E-mail: janalbert.wessels@nwu.ac.za; Retief, Francois, E-mail: francois.retief@nwu.ac.za; Morrison-Saunders, Angus, E-mail: A.Morrison-Saunders@murdoch.edu.au

    Independent Environmental Impact Assessment (EIA) follow-up verifiers such as monitoring agencies, checkers, supervisors and control officers are active on various construction sites across the world. There are, however, differing views on the value that these verifiers add and very limited learning in EIA has been drawn from independent verifiers. This paper aims to appraise how and to what extent independent EIA follow-up verifiers add value in major construction projects in the developing country context of South Africa. A framework for appraising the role of independent verifiers was established and four South African case studies were examined through a mixture ofmore » site visits, project document analysis, and interviews. Appraisal results were documented in the performance areas of: planning, doing, checking, acting, public participating and integration with other programs. The results indicate that independent verifiers add most value to major construction projects when involved with screening EIA requirements of new projects, allocation of financial and human resources, checking legal compliance, influencing implementation, reporting conformance results, community and stakeholder engagement, integration with self-responsibility programs such as environmental management systems (EMS), and controlling records. It was apparent that verifiers could be more creatively utilized in pre-construction preparation, providing feedback of knowledge into assessment of new projects, giving input to the planning and design phase of projects, and performance evaluation. The study confirms the benefits of proponent and regulator follow-up, specifically in having independent verifiers that disclose information, facilitate discussion among stakeholders, are adaptable and proactive, aid in the integration of EIA with other programs, and instill trust in EIA enforcement by conformance evaluation. Overall, the study provides insight on how to harness the learning opportunities arising from EIA follow-up through the appointment of independent verifiers. - Highlights: • A framework for appraising the role of independent verifiers is established. • The value added to EIA follow-up by independent verifiers in South Africa is documented. • Verifiers add most value when involved with screening, checking compliance, influencing decisions and community engagement. • Verifiers could be more creatively utilized in pre-construction preparation, giving feedback, and performance evaluation.« less

  9. Reactivity of commercially available monoclonal antibodies to human CD antigens with peripheral blood leucocytes of dromedary camels (Camelus dromedarius)

    PubMed Central

    Hussen, Jamal; Shawaf, Turke; Al-herz, Abdulkareem Imran; Alturaifi, Hussain R.; Alluwaimi, Ahmed M.

    2017-01-01

    Monoclonal antibodies (mAbs) to cell surface molecules have been proven as a key tool for phenotypic and functional characterization of the cellular immune response. One of the major difficulties in studying camel cellular immunity consists in the lack of mAbs that dtect their leukocyte differentiation antigens. In the present study two-parameter flow cytometry was used to screen existing commercially available mAbs to human leukocyte antigens and major histocompatibility molecules (MHC) for their reactivity with camel leukocytes. The comparison of patterns of reactivity obtained after labelling human and camel leukocytes have shown that mAbs specific to human cluster of differentiation (CD) 18, CD11a, CD11b and CD14 are predicted to be cross-reactive with homologous camel antigens. PMID:28652982

  10. Electron Detachment Dissociation (EDD) of Fluorescently Labeled Sialylated Oligosaccharides

    PubMed Central

    Zhou, Wen; Håkansson, Kristina

    2012-01-01

    We explored the application of electron detachment dissociation (EDD) and infrared multiphoton dissociation (IRMPD) tandem mass spectrometry to fluorescently labeled sialylated oligosaccharides. Standard sialylated oligosaccharides and a sialylated N-linked glycan released from human transferrin were investigated. EDD yielded extensive glycosidic cleavages and cross-ring cleavages in all cases studied, consistently providing complementary structural information compared to IRMPD. Neutral losses and satellite ions such as C – 2H ions were also observed following EDD. In addition, we examined the influence of different fluorescent labels. The acidic label 2-aminobenzoic acid (2-AA) enhanced signal abundance in negative-ion mode. However, few cross-ring fragments were observed for 2-AA labeled oligosaccharides. The neutral label 2-aminobenzamide (2-AB) resulted in more cross-ring cleavages compared to 2-AA labeled species, but not as extensive fragmentation as for native oligosaccharides, likely resulting from altered negative charge locations from introduction of the fluorescent tag. PMID:22120881

  11. Observations of equatorial ionization anomaly over Africa and Middle East during a year of deep minimum

    NASA Astrophysics Data System (ADS)

    Bolaji, Olawale; Owolabi, Oluwafisayo; Falayi, Elijah; Jimoh, Emmanuel; Kotoye, Afolabi; Odeyemi, Olumide; Rabiu, Babatunde; Doherty, Patricia; Yizengaw, Endawoke; Yamazaki, Yosuke; Adeniyi, Jacob; Kaka, Rafiat; Onanuga, Kehinde

    2017-01-01

    In this work, we investigated the veracity of an ion continuity equation in controlling equatorial ionization anomaly (EIA) morphology using total electron content (TEC) of 22 GPS receivers and three ground-based magnetometers (Magnetic Data Acquisition System, MAGDAS) over Africa and the Middle East (Africa-Middle East) during the quietest periods. Apart from further confirmation of the roles of equatorial electrojet (EEJ) and integrated equatorial electrojet (IEEJ) in determining hemispheric extent of EIA crest over higher latitudes, we found some additional roles played by thermospheric meridional neutral wind. Interestingly, the simultaneous observations of EIA crests in both hemispheres of Africa-Middle East showed different morphology compared to that reported over Asia. We also observed interesting latitudinal twin EIA crests domiciled at the low latitudes of the Northern Hemisphere. Our results further showed that weak EEJ strength associated with counter electrojet (CEJ) during sunrise hours could also trigger twin EIA crests over higher latitudes.

  12. Natural Gas Industry Restructuring and EIA Data Collection

    EIA Publications

    1996-01-01

    The Energy Information Administration's (EIA) Reserves and Natural Gas Division has undertaken an in-depth reevaluation of its programs in an effort to improve the focus and quality of the natural gas data that it gathers and reports. This article is to inform natural gas data users of proposed changes and of the opportunity to provide comments and input on the direction that EIA is taking to improve its data.

  13. Power and polarization dependences of ultra-narrow electromagnetically induced absorption (EIA) spectra of 85 Rb atoms in degenerate two-level system

    NASA Astrophysics Data System (ADS)

    Qureshi, Muhammad Mohsin; Rehman, Hafeez Ur; Noh, Heung-Ryoul; Kim, Jin-Tae

    2016-05-01

    We have investigated ultra-narrow EIA spectral features with respect to variations of polarizations and powers of pump laser beam in a degenerate two-level system of the transition of 85 Rb D2 transition line. Polarizations of the probe laser beam in two separate experiments were fixed at right circular and horizontal linear polarizations, respectively while the polarizations of the pump lasers were varied from initial polarizations same as the probe laser beams to orthogonal to probe polarizations. One homemade laser combined with AOMs was used to the pump and probe laser beams instead of two different lasers to overcome broad linewidths of the homemade lasers. Theoretically, probe absorption coefficients have been calculated from optical Bloch equations of the degenerate two level system prepared by a pump laser beam. In the case of the circular polarization, EIA signal was obtained as expected theoretically although both pump and probe beams have same polarization. The EIA signal become smaller as power increases and polarizations of the pump and probe beams were same. When the polarization of the pump beam was linear polarization, maximum EIA signal was obtained theoretically and experimentally. Experimental EIA spectral shapes with respect to variations of the pump beam polarization shows similar trends as the theoretical results.

  14. GIS as a vital tool for Environmental Impact Assessment and Mitigation

    NASA Astrophysics Data System (ADS)

    Gharehbaghi, Koorosh; Scott-Young, Christina

    2018-03-01

    Environmental Impact Assessment (EIA) is a course of action which provides information to various stakeholders such as planners and relevant authorities about the planned development and its subsequent effects of the environment and the immediate ambiances. Furthermore, the EIA and mitigation are the inclusive process of collecting, analyzing information and the determination of the application for development or construction approval, which could be accessible by the concerned communities and organizations. Although the set regulations of EIA and mitigation vary from jurisdictions, they are, however, very precise and need to be integrated with the specific geographical data. In addition, the Geographical Information System (GIS) is a software intended to encapsulate and present all types of physical, biological, environmental, ecological and geological information. Conversely, GIS is the integration of statistical analysis and information technology, and can also be further broken down into two different categories of; Topological Modelling and Map overlay. To ensure that the EIA and mitigation are receptive the GIS will provide the decisive apparatus. Using GIS not only improves the overall EIA and mitigation process, but also provides valuable mapping strategies, including holistic environmental system approach. Accordingly, the main objective of this paper is to discuss the importance of the GIS and Environmental Data integration progression, to further enhance the overall EIA and Mitigation processes.

  15. Health Impact Assessment practice and potential for integration within Environmental Impact and Strategic Environmental Assessments in Italy.

    PubMed

    Linzalone, Nunzia; Assennato, Giorgio; Ballarini, Adele; Cadum, Ennio; Cirillo, Mario; Cori, Liliana; De Maio, Francesca; Musmeci, Loredana; Natali, Marinella; Rieti, Sabrina; Soggiu, Maria Eleonora; Bianchi, Fabrizio

    2014-12-01

    Avoiding or minimizing potential environmental impact is the driving idea behind protecting a population's health via Environmental Impact Assessments (EIAs) and Strategic Environmental Assessments (SEAs). However, both are often carried out without any systematic approach. This paper describes the findings of a review of HIA, EIA andSEA experiences carried out by the authors, who act as institutional competent subjects at the national and regional levels in Italy. The analysis of how health is tackled in EIA and SEA procedures could support the definition of a protocol for the integration of HIA with EIA and SEA. Although EIA and SEA approaches include the aim of protecting health,significant technical and methodological gaps are present when assessing health systematically, and their basic principles regarding assessment are unsatisfactory for promoting and addressing healthcare concepts stated by the WHO. HIA is still poorly integrated into the decision-making process, screening and monitoring phases are only occasionally implemented, and operational details are not well-defined. The collaborative approach of institutions involved in environment and health is a core element in a systematic advancement toward supporting effective decisions and effective protection ofthe environment and health. At the Italian national level, the definition of guidelines and tools for HIA, also in relation with EIA and SEA, is of great interest.

  16. Reform of the EIA process in Indonesia: improving the role of public involvement

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Purnama, Dadang

    2003-07-01

    The implementation of Environmental Impact Assessment (EIA) as a planning tool has been utilised for a relatively long time in Indonesia. It was introduced formally through the Act No. 4/1982. Supporting regulation was established in 1986 when Government Regulation No. 29 was enacted. After developing the EIA system for 14 years, Indonesia finally recognized the importance of emphasizing public involvement in the EIA guidelines of 2000. EIA in the previous Indonesian regulations, i.e. Regulation No. 29/1986 and No. 51/1993, did not have provisions for direct public involvement. The Indonesian Government Regulation No. 27/1999 is currently accommodating the above issue. Guidelinesmore » for public announcement and public involvement have been introduced in a decree issued by the Head of Indonesia's Environmental Impact Management Agency No. KepDal 08/2000. This was officially enacted on 7 November 2000 in response to the demand for more public involvement, an issue that was ambiguous in the previous legislation. This paper discusses: the implementation of the new guidelines; what has been achieved; and the challenges during implementation. While the paper focuses its review on the Indonesian EIA system, Indonesia's experience is relevant to many other developing countries that are starting to adopt public involvement in their decision-making processes.« less

  17. Fast and Simple Detection of Yersinia pestis Applicable to Field Investigation of Plague Foci

    PubMed Central

    Simon, Stéphanie; Demeure, Christian; Lamourette, Patricia; Filali, Sofia; Plaisance, Marc; Créminon, Christophe; Volland, Hervé; Carniel, Elisabeth

    2013-01-01

    Yersinia pestis, the plague bacillus, has a rodent-flea-rodent life cycle but can also persist in the environment for various periods of time. There is now a convenient and effective test (F1-dipstick) for the rapid identification of Y. pestis from human patient or rodent samples, but this test cannot be applied to environmental or flea materials because the F1 capsule is mostly produced at 37°C. The plasminogen activator (PLA), a key virulence factor encoded by a Y. pestis-specific plasmid, is synthesized both at 20°C and 37°C, making it a good candidate antigen for environmental detection of Y. pestis by immunological methods. A recombinant PLA protein from Y. pestis synthesized by an Escherichia coli strain was used to produce monoclonal antibodies (mAbs). PLA-specific mAbs devoid of cross-reactions with other homologous proteins were further cloned. A pair of mAbs was selected based on its specificity, sensitivity, comprehensiveness, and ability to react with Y. pestis strains grown at different temperatures. These antibodies were used to develop a highly sensitive one-step PLA-enzyme immunoassay (PLA-EIA) and an immunostrip (PLA-dipstick), usable as a rapid test under field conditions. These two PLA-immunometric tests could be valuable, in addition to the F1-disptick, to confirm human plague diagnosis in non-endemic areas (WHO standard case definition). They have the supplementary advantage of allowing a rapid and easy detection of Y. pestis in environmental and flea samples, and would therefore be of great value for surveillance and epidemiological investigations of plague foci. Finally, they will be able to detect natural or genetically engineered F1-negative Y. pestis strains in human patients and environmental samples. PMID:23383008

  18. Evaluating public participation in Chinese EIA. An integrated Public Participation Index and its application to the case of the New Beijing Airport

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brombal, Daniele; Moriggi, Angela; Department of Environmental Sciences, Informatics and Statistics, University Ca' Foscari Venice

    In recent years, China's government authorities have devoted increasing attention to the role of public participation processes in Environmental Impact Assessment (EIA). The capacity of these processes to influence decision-making remains widely debated. This paper aims at appraising the institutional rationale informing the implementation of public participation in China's EIA, benchmarking it against three conceptualisations: (1) Normative, based on objectives of empowerment and democratisation; (2) Substantive, where participation is pursued mainly to improve quality of decisions; (3) Instrumental, seeking participation as an instrument to legitimise decision-making processes. The appraisal is carried out by means of a new integrated index (Publicmore » Participation Index, PPI), which is applied to a case study representative of latest advancements in EIA public participation practices in China, namely the “New Beijing Airport Project”. Located 46 km south of downtown Beijing, the project was approved in 2014 and it is currently under construction. Results of the PPI application to this case study indicate that, despite progress made in recent years, the implementation of public participation in Chinese EIA still largely responds to an instrumental rationale, with limited capacity for the public to affect decisions. - Highlights: • In recent years China has strengthened EIA public participation (PP) legislation. • Despite progress, implementation of PP remains informed by an instrumental rationale. • A large gap exists between principles enunciated in regulations and implementation. • The Public Participation Index can be used to monitor China's EIA PP development.« less

  19. Adenovirus EIIA early promoter: transcriptional control elements and induction by the viral pre-early EIA gene, which appears to be sequence independent.

    PubMed Central

    Murthy, S C; Bhat, G P; Thimmappaya, B

    1985-01-01

    A molecular dissection of the adenovirus EIIA early (E) promoter was undertaken to study the sequence elements required for transcription and to examine the nucleotide sequences, if any, specific for its trans-activation by the viral pre-early EIA gene product. A chimeric gene in which the EIIA-E promoter region fused to the coding sequences of the bacterial chloramphenicol acetyltransferase (CAT) gene was used in transient assays to identify the transcriptional control regions. Deletion mapping studies revealed that the upstream DNA sequences up to -86 were sufficient for the optimal basal level transcription in HeLa cells and also for the EIA-induced transcription. A series of linker-scanning (LS) mutants were constructed to precisely identify the nucleotide sequences that control transcription. Analysis of these LS mutants allowed us to identify two regions of the promoter that are critical for the EIIA-E transcription. These regions are located between -29 and -21 (region I) and between -82 and -66 (region II). Mutations in region I affected initiation and appeared functionally similar to the "TATA" sequence of the commonly studied promoters. To examine whether or not the EIIA-E promoter contained DNA sequences specific for the trans-activation by the EIA, the LS mutants were analyzed in a cotransfection assay containing a plasmid carrying the EIA gene. CAT activity of all of the LS mutants was induced by the EIA gene in this assay, suggesting that the induction of transcription of the EIIA-E promoter by the EIA gene is not sequence-specific. Images PMID:3857577

  20. An analysis of false positive reactions occurring with the Captia Syph G EIA.

    PubMed Central

    Ross, J; Moyes, A; Young, H; McMillan, A

    1991-01-01

    AIM--The Captia Syph G enzyme immuno assay (EAI) offers the potential for the rapid automated detection of syphilis antibodies. This study was designed to assess the role of other sexually transmitted diseases (STDs) in producing false positive reactions in the Captia Syph G EIA. The role of rheumatoid factor (RF) as a potential source of false positives was also analysed. METHODS--Patients who attended a genitourinary medicine (GUM) department and gave a false positive reaction with the EIA between 1988 and 1990 were compared with women undergoing antenatal testing and with the control clinic population (EIA negative) over the same time period. The incidence of sexually transmitted disease (STD) in the clinic population and the false positive reactors was measured in relation to gonorrhoea, chlamydia, genital warts, candidiasis, "other conditions not requiring treatment" and "other conditions requiring treatment." Male: female sex ratios were also compared. Ninety two RF positive sera were analysed with the EIA. RESULTS--The rate of false positive reactions did not differ with respect to the diagnosis within the GUM clinic population. The antenatal group of women, however, had a lower incidence of false positive reactions than the GUM clinic group. No RF positive sera were positive on Captia Syph G EIA testing. CONCLUSIONS--There is no cross reaction between Captia Syph G EIA and any specific STD or with RF positive sera. The lower incidence of false positive reactions in antenatal women is unexplained but may be related to physiological changes associated with pregnancy. PMID:1743715

  1. Comparative performance of electrochemiluminescence immunoassay and EIA for HIV screening in a multiethnic region of China.

    PubMed

    Bi, Xiaohui; Ning, Hongxia; Wang, Tingting; Li, Dongdong; Liu, Yongming; Yang, Tingfu; Yu, Jiansheng; Tao, Chuanmin

    2012-01-01

    The recent approval of 4th generation HIV tests has forced many laboratories to decide whether to shift from 3rd to these tests. There are limited published studies on the comparative evaluation of these two different assays. We compare the performance of fourth-generation electrochemiluminescence immunoassay (ChIA) and third-generation enzyme linked immunosorbent assay (EIA) for human immunodeficiency virus (HIV) screening and gauge whether the shift from EIA to ChIA could be better in a multiethnic region of China. We identified a large number of routine specimens (345,492) using two different assays from Jan 2008 to Aug 2011 in a teaching hospital with high sample throughput. Of the 344,596 specimens with interpretable HIV test results, 526(0.23%) of 228,761 using EIA and 303(0.26%) of 115,835 using ChIA were HIV-1 positive. The false-positive rate of EIA was lower than that of ChIA [0.03% vs. 0.08%, odds ratio 0.33 (95% confidence interval 0.24, 0.45)]. The positive predictive value (PPV) of EIA (89.6%) was significantly higher than that of ChIA (76.1%) (<0.001), reflecting the difference between the two assays. The clinical sensitivities of two assays in this study were 99.64% for EIA and 99.88% for ChIA. Caution is needed before shifting from 3rd to 4th generation HIV tests. Since none of these tests are perfect, different geographic and ethnic area probably require different considerations with regard to HIV testing methods, taking into account the local conditions.

  2. Usefulness of FC-TRIPLEX Chagas/Leish IgG1 as confirmatory assay for non-negative results in blood bank screening of Chagas disease.

    PubMed

    Campos, Fernanda Magalhães Freire; Repoles, Laura Cotta; de Araújo, Fernanda Fortes; Peruhype-Magalhães, Vanessa; Xavier, Marcelo Antônio Pascoal; Sabino, Ester Cerdeira; de Freitas Carneiro Proietti, Anna Bárbara; Andrade, Mariléia Chaves; Teixeira-Carvalho, Andréa; Martins-Filho, Olindo Assis; Gontijo, Célia Maria Ferreira

    2018-04-01

    A relevant issue in Chagas disease serological diagnosis regards the requirement of using several confirmatory methods to elucidate the status of non-negative results from blood bank screening. The development of a single reliable method may potentially contribute to distinguish true and false positive results. Our aim was to evaluate the performance of the multiplexed flow-cytometry anti-T. cruzi/Leishmania IgG1 serology/(FC-TRIPLEX Chagas/Leish IgG1) with three conventional confirmatory criteria (ELISA-EIA, Immunofluorescence assay-IIF and EIA/IIF consensus criterion) to define the final status of samples with actual/previous non-negative results during anti-T. cruzi ELISA-screening in blood banks. Apart from inconclusive results, the FC-TRIPLEX presented a weak agreement index with EIA, while a strong agreement was observed when either IIF or EIA/IIF consensus criteria were applied. Discriminant analysis and Spearman's correlation further corroborates the agreement scores. ROC curve analysis showed that FC-TRIPLEX performance indexes were higher when IIF and EIA/IIF consensus were used as a confirmatory criterion. Logistic regression analysis further demonstrated that the probability of FC-TRIPLEX to yield positive results was higher for inconclusive results from IIF and EIA/IIF consensus. Machine learning tools illustrated the high level of categorical agreement between FC-TRIPLEX versus IIF or EIA/IIF consensus. Together, these findings demonstrated the usefulness of FC-TRIPLEX as a tool to elucidate the status of non-negative results in blood bank screening of Chagas disease. Copyright © 2018. Published by Elsevier B.V.

  3. Development and Application of a Sensitive, Second Antibody Format Enzymeimmunoassay (EIA) for Estimation of Plasma FSH in Mithun (Bos frontalis).

    PubMed

    Mondal, Mohan; Baruah, Kishore Kumar; Prakash, B S

    2016-01-01

    Mithun (Bos frontalis) is a semi-wild rare ruminant species. A simple sensitive enzymeimmunoassay suitable for assaying FSH in the blood plasma of mithun is not available which thereby limits our ability to understand this species reproductive processes. Therefore, the aim of this article was to develop a simple and sensitive enzymeimmunoassay (EIA) for estimation of FSH in mithun plasma and apply the assay to understand the estrous cycle and superovulatory process in this species. To accomplish this goal, biotinylated FSH was bridged between streptavidin-peroxidase and immobilized antiserum in a competitive assay. Forty microlitre mithun plasma was used directly in the EIA. The FSH standards were prepared in hormone free plasma and ranged from 5-1280 pg/well/40 μL. The sensitivity of EIA was 5 pg/well FSH, which corresponds to 0.125 ng/mL plasma and the 50% relative binding sensitivity was 90 pg/well/40 μL. Although the shape of the standard curve was not influenced by different plasma volumes viz. 40 and 80 μL, a slight drop in the OD450 was observed with the increasing volume of plasma. Parallelism tests conducted between the endogenous mithun FSH and bovine FSH standards showed good homology between them. Plasma FSH estimated using the developed EIA and commercially available FSH EIA kit in the same samples were correlated (r = 0.98) and showed linearity. Both the Intra- and inter-assay CV were below 6%. Recovery of known concentrations of added FSH showed linearity (r = 0.99). The developed EIA was further validated biologically by estimating FSH in cyclic cows for the entire estrous cycle, in mithun heifers administered with GnRH analogues and in mithun cows during superovulatory treatment with FSH. In conclusion, the EIA developed for FSH determination in mithun blood plasma is simple and highly sensitive for estimation of mithun FSH in all physiological conditions.

  4. Comparison of premier CAMPY enzyme immunoassay (EIA), ProSpecT Campylobacter EIA, and ImmunoCard STAT! CAMPY tests with culture for laboratory diagnosis of Campylobacter enteric infections.

    PubMed

    Granato, Paul A; Chen, Li; Holiday, Iris; Rawling, Russell A; Novak-Weekley, Susan M; Quinlan, Tammy; Musser, Kimberlee A

    2010-11-01

    Campylobacter enteritis is a food-borne or waterborne illness caused almost exclusively by Campylobacter jejuni and, to a lesser extent, by Campylobacter coli. These organisms produce indistinguishable clinical diseases and together represent the second most common cause of bacterial diarrhea in the United States and the leading cause of enteric infection throughout the world. The conventional approach to the laboratory diagnosis of Campylobacter enteritis is based on the recovery of the organism from a stool specimen, which requires the use of a specialized medium incubated at 42°C for several days in an artificially created microaerophilic environment. Recently, several commercially available enzyme immunoassays (EIAs) have been developed for the direct detection of C. jejuni and C. coli in stool specimens. This study compared conventional culture with three EIA methods, the Premier CAMPY EIA (Meridian Bioscience, Cincinnati, OH), the ProSpecT Campylobacter EIA (Remel, Lenexa, KS), and the ImmunoCard STAT! CAMPY test (Meridian Bioscience, Cincinnati, OH), for the detection of C. jejuni and C. coli in 485 patient stool samples. Discordant results were arbitrated by using an in-house, real-time PCR assay that was developed and validated by a public health reference laboratory. Following analyses of the discrepant specimens by PCR, the sensitivity and specificity of both the Premier CAMPY and ProSpecT Campylobacter EIAs were 99.3% and 98%, respectively, while the ImmunoCard STAT! CAMPY test had a sensitivity of 98.5% and a specificity of 98.2%. By use of the PCR test as the reference standard, culture detected 127 of 135 Campylobacter-positive stool specimens, yielding a sensitivity of 94.1%. These results showed that the three EIAs evaluated in this study provide a rapid and reliable alternative for the laboratory diagnosis of enteric infections with C. jejuni and C. coli and that conventional culture may no longer be recognized as the "gold standard" for diagnosis.

  5. Clinical and economic impact of the introduction of a nucleic acid amplification assay for Clostridium difficile.

    PubMed

    Guinta, Margaret M; Bunnell, Kristen; Harrington, Amanda; Bleasdale, Susan; Danziger, Larry; Wenzler, Eric

    2017-12-04

    The clinical outcomes and cost implications of a diagnostic shift from an EIA- to PCR-based assay for Clostridium difficile infection (CDI) have not been completely described in the literature. The impact of the PCR-based assay on the incidence and duration of CDI therapy was compared to the EIA assay for patients with a negative CDI diagnostic result. Secondary clinical and economic outcomes were also evaluated. Independent predictors of receipt of antibiotic therapy were assessed via logistic regression. 141 EIA and 140 PCR patients were included. Significantly more patients were started or continued on anti-CDI antibiotic therapy after a known negative assay result in the EIA group (26 patients vs. 8 patients, P = 0.002). Duration of antibiotic therapy after a known negative result was significantly shorter in the PCR group (1 vs. 4 days, P = 0.029) and a 23% reduction in the number of tests obtained per patient was observed (1.41 ± 0.86 vs. 1.82 ± 1.35, P = 0.007). The over fourfold difference in per-test cost of the EIA assay ($8.33 vs. $42.86, P < 0.0001) was offset by the overall medication costs required for the increased treatment in the EIA group ($546.60 vs. $188.96, P = 0.191). Utilization of the EIA-based CDI assay was associated with increased odds of CDI treatment after a negative test (aOR 4.71, 95% CI 1.93-11.46, P = 0.001). The transition from an EIA to PCR-based assay for diagnosing CDI resulted in a significant decrease in the number of patients treated and the duration of treatment in response to a negative test result. This significant decrease in treatment resulted in decreased costs offsetting the utilization of a more expensive molecular test for patients with a negative CDI diagnostic result.

  6. Assessment of IRI-2012, NeQuick-2 and IRI-Plas 2015 models with observed equatorial ionization anomaly in Africa during 2009 sudden stratospheric warming event

    NASA Astrophysics Data System (ADS)

    Bolaji, O. S.; Oyeyemi, E. O.; Adewale, A. O.; Wu, Q.; Okoh, D.; Doherty, P. H.; Kaka, R. O.; Abbas, M.; Owolabi, C.; Jidele, P. A.

    2017-11-01

    In Africa, we assessed the performance of all the three options of International Reference Ionosphere 2012, IRI-2012 (i.e. IRI-2001, IRI-2001COR and IRI-NeQuick), NeQuick-2 and IRI-Plas 2015 models prior to and during 2009 sudden stratospheric warming (SSW) event to predict equatorial ionization anomaly (EIA) crest locations and their magnitudes using total electron content (TEC) from experimental records of Global Positioning System (GPS). We confirmed that the IRI-Plas 2015 that appeared as the best compared to all of the models as regard prediction of the EIA crest locations in the northern hemisphere of Africa is due to discontinuities in the GPS data between ∼8° N and 22° N. As regard the predictions of EIA crest magnitudes and the location of EIA crests in the southern hemisphere of Africa, they are not present in all the models. The NeQuick-2 model does not have the capability to predict either the EIA crest location in the northern or southern hemisphere. The SSW effect on the low latitude was able to modify a single EIA crest to pre-noon and post noon EIA crests in the northern hemisphere during the SSW peak phase and significantly reduced the GPS TEC magnitudes over the hemispheres as well. These SSW effects and delays of plasma transportation to higher latitudes in GPS TEC were absent in all the models. For future improvements of IRI-2012, NeQuick-2 and IRI-Plas 2015 models, SSW conditions should be included in order to characterize the effect of lower atmosphere on the ionosphere. The EIA trough modeling is only present in IRI-2001COR and IRI-2001NeQuick options. In the middle latitude, all the model could not predict the location of highest TEC magnitudes found at RBAY (Richardsbay, South Africa).

  7. Noninvasive brain cancer imaging with a bispecific antibody fragment, generated via click chemistry.

    PubMed

    Luo, Haiming; Hernandez, Reinier; Hong, Hao; Graves, Stephen A; Yang, Yunan; England, Christopher G; Theuer, Charles P; Nickles, Robert J; Cai, Weibo

    2015-10-13

    Early diagnosis remains a task of upmost importance for reducing cancer morbidity and mortality. Successful development of highly specific companion diagnostics targeting aberrant molecular pathways of cancer is needed for sensitive detection, accurate diagnosis, and opportune therapeutic intervention. Herein, we generated a bispecific immunoconjugate [denoted as Bs-F(ab)2] by linking two antibody Fab fragments, an anti-epidermal growth factor receptor (EGFR) Fab and an anti-CD105 Fab, via bioorthogonal "click" ligation of trans-cyclooctene and tetrazine. PET imaging of mice bearing U87MG (EGFR/CD105(+/+)) tumors with (64)Cu-labeled Bs-F(ab)2 revealed a significantly enhanced tumor uptake [42.9 ± 9.5 percentage injected dose per gram (%ID/g); n = 4] and tumor-to-background ratio (tumor/muscle ratio of 120.2 ± 44.4 at 36 h postinjection; n = 4) compared with each monospecific Fab tracer. Thus, we demonstrated that dual targeting of EGFR and CD105 provides a synergistic improvement on both affinity and specificity of (64)Cu-NOTA-Bs-F(ab)2. (64)Cu-NOTA-Bs-F(ab)2 was able to visualize small U87MG tumor nodules (<5 mm in diameter), owing to high tumor uptake (31.4 ± 10.8%ID/g at 36 h postinjection) and a tumor/muscle ratio of 76.4 ± 52.3, which provided excellent sensitivity for early detection. Finally, we successfully confirmed the feasibility of a ZW800-1-labeled Bs-F(ab)2 for near-infrared fluorescence imaging and image-guided surgical resection of U87MG tumors. More importantly, our rationale can be used in the construction of other disease-targeting bispecific antibody fragments for early detection and diagnosis of small malignant lesions.

  8. Identification of a New cry1I-Type Gene as a Candidate for Gene Pyramiding in Corn To Control Ostrinia Species Larvae

    PubMed Central

    Zhao, Can; Abdelgaffar, Heba M.; Pan, Hongyu; Song, Fuping

    2015-01-01

    Pyramiding of diverse cry toxin genes from Bacillus thuringiensis with different modes of action is a desirable strategy to delay the evolution of resistance in the European corn borer (Ostrinia nubilalis). Considering the dependency of susceptibility to Cry toxins on toxin binding to receptors in the midgut of target pests, a diverse mode of action is commonly defined as recognition of unique binding sites in the target insect. In this study, we present a novel cry1Ie toxin gene (cry1Ie2) as a candidate for pyramiding with Cry1Ab or Cry1Fa in corn to control Ostrinia species larvae. The new toxin gene encodes an 81-kDa protein that is processed to a protease-resistant core form of approximately 55 kDa by trypsin digestion. The purified protoxin displayed high toxicity to Ostrinia furnacalis and O. nubilalis larvae but low to no activity against Spodoptera or heliothine species or the coleopteran Tenebrio molitor. Results of binding assays with 125I-labeled Cry1Ab toxin and brush border membrane vesicles from O. nubilalis larvae demonstrated that Cry1Ie2 does not recognize the Cry1Ab binding sites in that insect. Reciprocal competition binding assays with biotin-labeled Cry1Ie2 confirmed the lack of shared sites with Cry1Ab or Cry1Fa in O. nubilalis brush border membrane vesicles. These data support Cry1Ie2 as a good candidate for pyramiding with Cry1Ab or Cry1Fa in corn to increase the control of O. nubilalis and reduce the risk of resistance evolution. PMID:25795679

  9. Identification of a New cry1I-Type Gene as a Candidate for Gene Pyramiding in Corn To Control Ostrinia Species Larvae.

    PubMed

    Zhao, Can; Jurat-Fuentes, Juan Luis; Abdelgaffar, Heba M; Pan, Hongyu; Song, Fuping; Zhang, Jie

    2015-06-01

    Pyramiding of diverse cry toxin genes from Bacillus thuringiensis with different modes of action is a desirable strategy to delay the evolution of resistance in the European corn borer (Ostrinia nubilalis). Considering the dependency of susceptibility to Cry toxins on toxin binding to receptors in the midgut of target pests, a diverse mode of action is commonly defined as recognition of unique binding sites in the target insect. In this study, we present a novel cry1Ie toxin gene (cry1Ie2) as a candidate for pyramiding with Cry1Ab or Cry1Fa in corn to control Ostrinia species larvae. The new toxin gene encodes an 81-kDa protein that is processed to a protease-resistant core form of approximately 55 kDa by trypsin digestion. The purified protoxin displayed high toxicity to Ostrinia furnacalis and O. nubilalis larvae but low to no activity against Spodoptera or heliothine species or the coleopteran Tenebrio molitor. Results of binding assays with (125)I-labeled Cry1Ab toxin and brush border membrane vesicles from O. nubilalis larvae demonstrated that Cry1Ie2 does not recognize the Cry1Ab binding sites in that insect. Reciprocal competition binding assays with biotin-labeled Cry1Ie2 confirmed the lack of shared sites with Cry1Ab or Cry1Fa in O. nubilalis brush border membrane vesicles. These data support Cry1Ie2 as a good candidate for pyramiding with Cry1Ab or Cry1Fa in corn to increase the control of O. nubilalis and reduce the risk of resistance evolution. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  10. Highly efficient circulating tumor cell isolation from whole blood and label-free enumeration using polymer-based microfluidics with an integrated conductivity sensor.

    PubMed

    Adams, André A; Okagbare, Paul I; Feng, Juan; Hupert, Matuesz L; Patterson, Don; Göttert, Jost; McCarley, Robin L; Nikitopoulos, Dimitris; Murphy, Michael C; Soper, Steven A

    2008-07-09

    A novel microfluidic device that can selectively and specifically isolate exceedingly small numbers of circulating tumor cells (CTCs) through a monoclonal antibody (mAB) mediated process by sampling large input volumes (>/=1 mL) of whole blood directly in short time periods (<37 min) was demonstrated. The CTCs were concentrated into small volumes (190 nL), and the number of cells captured was read without labeling using an integrated conductivity sensor following release from the capture surface. The microfluidic device contained a series (51) of high-aspect ratio microchannels (35 mum width x 150 mum depth) that were replicated in poly(methyl methacrylate), PMMA, from a metal mold master. The microchannel walls were covalently decorated with mABs directed against breast cancer cells overexpressing the epithelial cell adhesion molecule (EpCAM). This microfluidic device could accept inputs of whole blood, and its CTC capture efficiency was made highly quantitative (>97%) by designing capture channels with the appropriate widths and heights. The isolated CTCs were readily released from the mAB capturing surface using trypsin. The released CTCs were then enumerated on-device using a novel, label-free solution conductivity route capable of detecting single tumor cells traveling through the detection electrodes. The conductivity readout provided near 100% detection efficiency and exquisite specificity for CTCs due to scaling factors and the nonoptimal electrical properties of potential interferences (erythrocytes or leukocytes). The simplicity in manufacturing the device and its ease of operation make it attractive for clinical applications requiring one-time use operation.

  11. Correlation between positron emission tomography and Cerenkov luminescence imaging in vivo and ex vivo using 64Cu-labeled antibodies in a neuroblastoma mouse model.

    PubMed

    Maier, Florian C; Schmitt, Julia; Maurer, Andreas; Ehrlichmann, Walter; Reischl, Gerald; Nikolaou, Konstantin; Handgretinger, Rupert; Pichler, Bernd J; Thaiss, Wolfgang M

    2016-10-11

    Antibody-based therapies gain momentum in clinical therapy, thus the need for accurate imaging modalities with respect to target identification and therapy monitoring are of increasing relevance. Cerenkov luminescence imaging (CLI) are a novel method detecting charged particles emitted during radioactive decay with optical imaging. Here, we compare Position Emission Tomography (PET) with CLI in a multimodal imaging study aiming at the fast and efficient screening of monoclonal antibodies (mAb) designated for targeting of the neuroblastoma-characteristic epitope disialoganglioside GD2. Neuroblastoma-bearing SHO mice were injected with a 64Cu-labeled GD2-specific mAb. The tumor uptake was imaged 3 h, 24 h and 48 h after tracer injection with both, PET and CLI, and was compared to the accumulation in GD2-negative control tumors (human embryonic kidney, HEK-293). In addition to an in vivo PET/CLI-correlation over time, we also demonstrate linear correlations of CLI- and γ-counter-based biodistribution analysis. CLI with its comparably short acquisition time can thus be used as an attractive one-stop-shop modality for the longitudinal monitoring of antibody-based tumor targeting and ex vivo biodistribution.These findings suggest CLI as a reliable alternative for PET and biodistribution studies with respect to fast and high-throughput screenings in subcutaneous tumors traced with radiolabeled antibodies. However, in contrast to PET, CLI is not limited to positron-emitting isotopes and can therefore also be used for the visualization of mAb labeled with therapeutic isotopes like electron emitters.

  12. Highly Efficient Circulating Tumor Cell Isolation from Whole Blood and Label-Free Enumeration Using Polymer-Based Microfluidics with an Integrated Conductivity Sensor

    PubMed Central

    Adams, André A.; Okagbare, Paul I.; Feng, Juan; Hupert, Matuesz L.; Patterson, Don; Göttert, Jost; McCarley, Robin L.; Nikitopoulos, Dimitris; Murphy, Michael C.; Soper, Steven A.

    2008-01-01

    A novel microfluidic device that can selectively and specifically isolate exceedingly small numbers of circulating tumor cells (CTCs) through a monoclonal antibody (mAB) mediated process by sampling large input volumes (≥1 mL) of whole blood directly in short time periods (<37 min) was demonstrated. The CTCs were concentrated into small volumes (190 nL), and the number of cells captured was read without labeling using an integrated conductivity sensor following release from the capture surface. The microfluidic device contained a series (51) of high-aspect ratio microchannels (35 μm width × 150 μm depth) that were replicated in poly(methyl methacrylate), PMMA, from a metal mold master. The microchannel walls were covalently decorated with mABs directed against breast cancer cells overexpressing the epithelial cell adhesion molecule (EpCAM). This microfluidic device could accept inputs of whole blood, and its CTC capture efficiency was made highly quantitative (>97%) by designing capture channels with the appropriate widths and heights. The isolated CTCs were readily released from the mAB capturing surface using trypsin. The released CTCs were then enumerated on-device using a novel, label-free solution conductivity route capable of detecting single tumor cells traveling through the detection electrodes. The conductivity readout provided near 100% detection efficiency and exquisite specificity for CTCs due to scaling factors and the nonoptimal electrical properties of potential interferences (erythrocytes or leukocytes). The simplicity in manufacturing the device and its ease of operation make it attractive for clinical applications requiring one-time use operation. PMID:18557614

  13. Arabinogalactan proteins and pectin distribution during female gametogenesis in Quercus suber L.

    PubMed Central

    Lopes, Ana Lúcia; Costa, Mário Luís; Sobral, Rómulo; Costa, Maria Manuela; Amorim, Maria Isabel; Coimbra, Sílvia

    2016-01-01

    Background and Aims Quercus suber L. (cork oak) is one of the most important monoecious tree species in semi-arid regions of Southern Europe, with a high ecological value and economic potential. However, as a result of its long reproductive cycle, complex reproductive biology and recalcitrant seeds, conventional breeding is demanding. In its complex reproductive biology, little is known about the most important changes that occur during female gametogenesis. Arabinogalactan proteins (AGPs) and pectins are the main components of plant cell walls and have been reported to perform common functions in cell differentiation and organogenesis of reproductive plant structures. AGPs have been shown to serve as important molecules in several steps of the reproductive process in plants, working as signalling molecules, associated with the sporophyte–gametophyte transition, and pectins have been implicated in pollen–pistil interactions before double fertilization. In this study, the distribution of AGP and pectin epitopes was assessed during female gametogenesis. Methods Immunofluorescence labelling of female flower cells was performed with a set of monoclonal antibodies (mAbs) directed to the carbohydrate moiety of AGPs (JIM8 and JIM13) and pectic homogalacturonans (HGs) (mAbs JIM5 and JIM7). Key Results The selective labelling obtained with AGP and pectin mAbs JIM8, JIM13, JIM5 and JIM7 during Q. suber female gametogenesis shows that AGPs and pectic HG can work as markers for mapping gametophytic cell differentiation in this species. Pectic HG showed different distribution patterns, depending on their levels of methyl esterification. Methyl-esterified HGs showed a uniform distribution in the overall female flower cells before fertilization and a more specific pattern after fertilization. A low methyl-ester pectin distribution pattern during the different developmental stages appears to be related to the pathway that pollen tubes follow to reach the embryo sac. AGPs showed a more sparse distribution in early stages of development, but specific labelling is shown in the synergids and their filiform apparatus. Conclusions The labelling obtained with anti-AGP and anti-pectin mAbs in Q. suber female flower cells showed a dynamic distribution of AGPs and pectic HGs, which may render these molecules useful molecular markers during female gametogenesis. Changes occurring during development will be determined in order to help describe cork oak ovule structural properties before and after fertilization, providing new insight to better understand Q. suber female gametogenesis. PMID:26994101

  14. Radiolabeled F(ab')2-cetuximab for theranostic purposes in colorectal and skin tumor-bearing mice models.

    PubMed

    Bellaye, P-S; Moreau, M; Raguin, O; Oudot, A; Bernhard, C; Vrigneaud, J-M; Dumont, L; Vandroux, D; Denat, F; Cochet, A; Brunotte, F; Collin, B

    2018-05-17

    This study aimed to investigate theranostic strategies in colorectal and skin cancer based on fragments of cetuximab, an anti-EGFR mAb, labeled with radionuclide with imaging and therapeutic properties, 111 In and 177 Lu, respectively. We designed F(ab') 2 -fragments of cetuximab radiolabeled with 111 In and 177 Lu. 111 In-F(ab') 2 -cetuximab tumor targeting and biodistribution were evaluated by SPECT in BalbC nude mice bearing primary colorectal tumors. The efficacy of 111 In-F(ab') 2 -cetuximab to assess therapy efficacy was performed on BalbC nude mice bearing colorectal tumors receiving 17-DMAG, an HSP90 inhibitor. Therapeutic efficacy of the radioimmunotherapy based on 177 Lu-F(ab') 2 -cetuximab was evaluated in SWISS nude mice bearing A431 tumors. Radiolabeling procedure did not change F(ab') 2 -cetuximab and cetuximab immunoreactivity nor affinity for HER1 in vitro. 111 In-DOTAGA-F(ab') 2 -cetuximab exhibited a peak tumor uptake at 24 h post-injection and showed a high tumor specificity determined by a significant decrease in tumor uptake after the addition of an excess of unlabeled-DOTAGA-F(ab') 2 -cetuximab. SPECT imaging of 111 In-DOTAGA-F(ab') 2 -cetuximab allowed an accurate evaluation of tumor growth and successfully predicted the decrease in tumor growth induced by 17-DMAG. Finally, 177 Lu-DOTAGA-F(ab') 2 -cetuximab radioimmunotherapy showed a significant reduction of tumor growth at 4 and 8 MBq doses. 111 In-DOTAGA-F(ab') 2 -cetuximab is a reliable and stable tool for specific in vivo tumor targeting and is suitable for therapy efficacy assessment. 177 Lu-DOTAGA-F(ab') 2 -cetuximab is an interesting theranostic tool allowing therapy and imaging.

  15. Comparison of clinical performance of antigen based-enzyme immunoassay (EIA) and major outer membrane protein (MOMP)-PCR for detection of genital Chlamydia trachomatis infection.

    PubMed

    Nateghi Rostami, Mahmoud; Hossein Rashidi, Batool; Aghsaghloo, Fatemeh; Nazari, Razieh

    2016-06-01

    Chlamydia trachomatis is the most common sexually transmitted bacterial pathogen worldwide. Early detection and treatment of C.trachomatis genital infection prevent serious reproductive complications. Performances of enzyme immunoassay (EIA) and major outer membrane protein (MOMP)-polymerase chain reaction (PCR) for diagnosis of genital C.trachomatis infection in women were compared. In this cross sectional study a total of 518 women volunteers were included (33.67±8.3 yrs) who had been referred to Gynecology clinics of Qom province, Iran, were included. Endocervical swab specimens were collected to detect lipopolysaccharide (LPS) antigen in EIA and to amplify MOMP gene of C.trachomatis in PCR. Results were confirmed using ompI nested-PCR. Sensitivity, specificity, positive (PPV) and negative predictive values (NPV) were calculated for performance of the tests. Odds ratios were determined using binary logistic regression analysis. In total, 37 (7.14%) cases were positive by EIA and/or MOMP-PCR. All discrepant results were confirmed by nested-PCR. Sensitivity, specificity, PPV and NPV values of EIA were 59.46%, 100%, 100% and 96.98%, and those of MOMP-PCR were 97.30%, 100%, 100%, 99.79%, respectively. Reproductive complications including 2.7% ectopic pregnancy, 5.4% stillbirth, 5.4% infertility, and 10.8% PROM were recorded. The risk of developing chlamydiosis was increased 4.8-fold in volunteers with cervicitis (p<0.05; OR 4.80; 95% CI 1.25-18.48). C.trachomatis infection should be regarded in women of reproductive ages especially those with cervicitis. Primary screening of women by using the low cost antigen-EIA is recommended; however, due to the low sensitivity of Ag-EIA, verification of the negative results by a DNA amplification method is needed.

  16. Development, evaluation, and laboratory validation of immunoassays for the diagnosis of equine infectious anemia (EIA) using recombinant protein produced from a synthetic p26 gene of EIA virus.

    PubMed

    Singha, Harisankar; Goyal, Sachin K; Malik, Praveen; Khurana, Sandip K; Singh, Raj K

    2013-12-01

    Equine infectious anemia (EIA)-a retroviral disease caused by equine infectious anemia virus (EIAV)-is a chronic, debilitating disease of horses, mules, and donkeys. EIAV infection has been reported worldwide and is recognized as pathogen of significant economic importance to the horse industry. This disease falls under regulatory control program in many countries including India. Control of EIA is based on identification of inapparent carriers by detection of antibodies to EIAV in serologic tests and "Stamping Out" policy. The current internationally accepted test for diagnosis of EIA is the agar gel immune-diffusion test (AGID), which detects antibodies to the major gag gene (p26) product. The objective of this study was to develop recombinant p26 based in-house immunoassays [enzyme linked immunosorbent assays (ELISA), and AGID] for EIA diagnosis. The synthetic p26 gene of EIAV was expressed in Escherichia coli and diagnostic potential of recombinant p26 protein were evaluated in ELISA and AGID on 7,150 and 1,200 equine serum samples, respectively, and compared with commercial standard AGID kit. The relative sensitivity and specificity of the newly developed ELISA were 100 and 98.6 %, respectively. Whereas, relative sensitivity and specificity of the newly developed AGID were in complete agreement in respect to commercial AGID kit. Here, we have reported the validation of an ELISA and AGID on large number of equine serum samples using recombinant p26 protein produced from synthetic gene which does not require handling of pathogenic EIAV. Since the indigenously developed reagents would be economical than commercial diagnostic kit, the rp26 based-immunoassays could be adopted for the sero-diagnosis and control of EIA in India.

  17. Comparative evaluation of the Ridascreen Verotoxin enzyme immunoassay for detection of Shiga-toxin producing strains of Escherichia coli (STEC) from food and other sources.

    PubMed

    Beutin, L; Steinrück, H; Krause, G; Steege, K; Haby, S; Hultsch, G; Appel, B

    2007-03-01

    To evaluate the suitability of the commercially distributed Ridascreen Verotoxin enzyme immunoassay (EIA) for detection of known genetic types of the Vero (Shiga) toxins 1 (Stx1) and 2 (Stx2) families and to determine its relative sensitivity and specificity. The Ridascreen-EIA was compared with the Vero cell assay, a P(1)-glycoprotein receptor EIA and with stx gene-specific PCs for detection of Stx with 43 Shiga toxin-producing strains of Escherichia coli (STEC) reference strains and with 241 test strains. The Ridascreen-EIA detects strains producing Stx1 and variants Stx1c and Stx1d, as well as Stx2 and variants Stx2d1, Stx2d2, Stx2e, Stx2d, Stx2-O118 (Stx2d-ount), Stx2-NV206, Stx2f and Stx2g. The assay showed a relative sensitivity of 95.7% and a relative specificity of 98.7%. Some of the Stx2-O118-, Stx2e- and Stx2g-producing STEC were not detected with the Ridascreen-EIA probably because of low amount of toxin produced by these strains. The Ridascreen-EIA is able to detect all known types of Stx and is applicable for routine screening of bacterial isolates owing to its high specificity. It is less applicable for testing samples where low amounts of Stx are expected, such as mixed cultures and certain Stx2 variants. This study presents a first comprehensive evaluation of the Ridascreen-EIA, a rapid standardized STEC screening test for routine diagnostic laboratories. Data are presented on the type of the spectrum of Stx that are detected with this immunoassay and its advantages and limits for practical use.

  18. Correlation between oestrogen receptor protein expression in infiltrating ductal carcinoma of the breast by immunohistochemistry and cytosol measurements.

    PubMed

    Looi, L M; Yap, S F; Cheah, P L

    1997-11-01

    Fresh frozen neoplastic tissues from 70 infiltrating ductal breast carcinomas were analysed for cytosolic oestrogen receptor (ER) protein content using a solid phase enzyme immunoassay (EIA) method based on a "sandwich" principle (Abbott ER-EIA monoclonal). Formalin-fixed, paraffin-embedded sections from the same carcinomas were examined for nuclear immunoreactivity against a monoclonal antibody for ER protein (Dako) using the standard avidin-biotin complex immunoperoxidase (IP) method after microwave antigen retrieval. The degree of ER positivity by IP was also scored according to a visual estimation of the percentage of cells expressing immunopositivity and the intensity of staining. Twenty-eight (40%) of the carcinomas were ER-positive by EIA and 34 (48.6%) were positive by IP. Twenty-five (35.7%) were ER-positive and 33 (47.1%) were ER-negative by both methods. Nine (12.9%) were ER-negative by EIA but were positive by IP, this discrepancy being ascribed to sampling inadequacy for EIA. However, 3 (4.3%) tumours were ER-positive by EIA and negative by IP. This discrepancy may be variously due to inadequate antigen retrieval, faulty technique and the possibility that the two methods do not measure identical ER proteins. IP appears to have an advantage over EIA in that it has a higher pick-up rate, does not require fresh tissue and can be applied to archival material. However, to reduce false negative estimations, it may be necessary to run IP staining using more than one ER antibody. Standardisation of the IP method for ER is desirable before this method is to be widely adopted in Malaysian laboratories. Quantitation of ER positivity by IP scoring correlated poorly with actual cytosolic levels. Caution should be exercised in attaching patient management value to visual IP scoring.

  19. Development and evaluation of a new lateral flow assay for simultaneous detection of antibodies against African Horse Sickness and Equine Infectious Anemia viruses.

    PubMed

    Costa, Sofia; Sastre, Patricia; Pérez, Teresa; Tapia, Istar; Barrandeguy, María; Sánchez-Vizcaíno, José M; Sánchez-Matamoros, Almudena; Wigdorovitz, Andrés; Sanz, Antonio; Rueda, Paloma

    2016-11-01

    African horse sickness (AHS) and equine infectious anemia (EIA) are both notifiable equid specific diseases that may present similar clinical signs. Considering the increased global movement of horses and equine products over the past decades, together with the socio-economic impact of previous AHS and EIA outbreaks, there is a clear demand for an early discrimination and a strict control of their transmission between enzootic and AHS/EIA-free regions. Currently, the individual control and prevention of AHS or EIA relies on a series of measures, including the restriction of animal movements, vector control, and the use of several laboratory techniques for viral identification, amongst others. Despite being widely employed in surveillance programmes and in the control of animal movements, the available serological assays can only detect AHS- or EIA-specific antibodies individually. In this work, a duplex lateral flow assay (LFA) for simultaneous detection and differentiation of specific antibodies against AHS virus (AHSV) and EIA virus (EIAV) was developed and evaluated with experimental and field serum samples. The duplex LFA was based on the AHSV-VP7 outer core protein and the EIAV-P26 major core protein. The results indicated that the duplex LFA presented a good analytical performance, detecting simultaneously and specifically antibodies against AHSV and EIAV. The initial diagnostic evaluation revealed a good agreement with results from the AHS and EIA tests prescribed by the OIE, and it highlighted the usefulness of the new AHSV/EIAV duplex LFA for an on-field and point-of-care first diagnosis. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Quality of Antiepileptic Treatment Among Older Medicare Beneficiaries With Epilepsy: A Retrospective Claims Data Analysis.

    PubMed

    Pisu, Maria; Richman, Joshua; Piper, Kendra; Martin, Roy; Funkhouser, Ellen; Dai, Chen; Juarez, Lucia; Szaflarski, Jerzy P; Faught, Edward

    2017-07-01

    Enzyme-inducing antiepileptic drugs (EI-AEDs) are not recommended for older adults with epilepsy. Quality Indicator for Epilepsy Treatment 9 (QUIET-9) states that new patients should not receive EI-AEDs as first line of treatment. In light of reported racial/ethnic disparities in epilepsy care, we investigated EI-AED use and QUIET-9 concordance across major racial/ethnic groups of Medicare beneficiaries. Retrospective analyses of 2008-2010 Medicare claims for a 5% random sample of beneficiaries 67 years old and above in 2009 augmented for minority representation. Logistic regressions examined QUIET-9 concordance differences by race/ethnicity adjusting for individual, socioeconomic, and geography factors. Epilepsy prevalent (≥1 International Classification of Disease-version 9 code 345.x or ≥2 International Classification of Disease-version 9 code 780.3x, ≥1 AED), and new (same as prevalent+no seizure/epilepsy events nor AEDs in 365 d before index event) cases. Use of EI-AEDs and QUIET-9 concordance (no EI-AEDs for the first 2 AEDs). Cases were 21% white, 58% African American, 12% Hispanic, 6% Asian, 2% American Indian/Alaskan Native. About 65% of prevalent, 43.6% of new cases, used EI-AEDs. QUIET-9 concordance was found for 71% Asian, 65% white, 61% Hispanic, 57% African American, 55% American Indian/Alaskan new cases: racial/ethnic differences were not significant in adjusted model. Beneficiaries without neurology care, in deductible drug benefit phase, or in high poverty areas were less likely to have QUIET-9 concordant care. EI-AED use is high, and concordance with recommendations low, among all racial/ethnic groups of older adults with epilepsy. Potential socioeconomic disparities and drug coverage plans may affect treatment quality and opportunities to live well with epilepsy.

  1. Large-Scale Evaluation of the Immuno-Mycologics Lateral Flow and Enzyme-Linked Immunoassays for Detection of Cryptococcal Antigen in Serum and Cerebrospinal Fluid

    PubMed Central

    Hansen, Jessica; Slechta, E. Susan; Gates-Hollingsworth, Marcellene A.; Neary, Brandon; Barker, Adam P.; Bauman, Sean; Kozel, Thomas R.

    2013-01-01

    Cryptococcosis is a systemic infection caused by the pathogenic yeasts Cryptococcus neoformans and C. gattii. Detection of cryptococcal capsular antigen (CrAg) in serum and cerebrospinal fluid (CSF) plays an important diagnostic role. We prospectively compared the new Immuno-Mycologics Inc. (IMMY) lateral flow assay (LFA) and enzyme immunoassay (EIA) to our current CrAg test (Premier EIA; Meridian Bioscience Inc.). Discordant samples were retested with the latex-Cryptococcus antigen test (IMMY) and using serotype-specific monoclonal antibodies (MAbs). A total of 589 serum and 411 CSF specimens were tested in parallel. Qualitative agreement across assays was 97.7%. In all, 56 (41 serum and 15 CSF) samples were positive and 921 (527 serum and 394 CSF) samples were negative by all three assays. The 23 discrepant specimens were all Meridian EIA negative. Of 23 discordant specimens, 20 (87.0%) were positive by both the IMMY LFA and EIA, 2 were LFA positive only, and 1 was EIA positive only. Eleven discrepant specimens had adequate volume for latex agglutination (LA) testing; 8 were LA positive, and 3 were LA negative. LA-negative samples (2 CSF samples and 1 serum) had low IMMY LFA/EIA titers (≤1:10). Serotype-specific MAb analysis of the LA-positive samples suggested that these specimens contained CrAg epitopes similar to those of serotype C strains. In conclusion, the IMMY assays showed excellent overall concordance with the Meridian EIA. Assay performance differences were related to issues of analytic sensitivity and possible serotype bias. Incomplete access to patient-level data combined with low specimen volumes limited our ability to fully resolve discrepant results. PMID:23114703

  2. Large-scale evaluation of the immuno-mycologics lateral flow and enzyme-linked immunoassays for detection of cryptococcal antigen in serum and cerebrospinal fluid.

    PubMed

    Hansen, Jessica; Slechta, E Susan; Gates-Hollingsworth, Marcellene A; Neary, Brandon; Barker, Adam P; Bauman, Sean; Kozel, Thomas R; Hanson, Kimberly E

    2013-01-01

    Cryptococcosis is a systemic infection caused by the pathogenic yeasts Cryptococcus neoformans and C. gattii. Detection of cryptococcal capsular antigen (CrAg) in serum and cerebrospinal fluid (CSF) plays an important diagnostic role. We prospectively compared the new Immuno-Mycologics Inc. (IMMY) lateral flow assay (LFA) and enzyme immunoassay (EIA) to our current CrAg test (Premier EIA; Meridian Bioscience Inc.). Discordant samples were retested with the latex-Cryptococcus antigen test (IMMY) and using serotype-specific monoclonal antibodies (MAbs). A total of 589 serum and 411 CSF specimens were tested in parallel. Qualitative agreement across assays was 97.7%. In all, 56 (41 serum and 15 CSF) samples were positive and 921 (527 serum and 394 CSF) samples were negative by all three assays. The 23 discrepant specimens were all Meridian EIA negative. Of 23 discordant specimens, 20 (87.0%) were positive by both the IMMY LFA and EIA, 2 were LFA positive only, and 1 was EIA positive only. Eleven discrepant specimens had adequate volume for latex agglutination (LA) testing; 8 were LA positive, and 3 were LA negative. LA-negative samples (2 CSF samples and 1 serum) had low IMMY LFA/EIA titers (≤1:10). Serotype-specific MAb analysis of the LA-positive samples suggested that these specimens contained CrAg epitopes similar to those of serotype C strains. In conclusion, the IMMY assays showed excellent overall concordance with the Meridian EIA. Assay performance differences were related to issues of analytic sensitivity and possible serotype bias. Incomplete access to patient-level data combined with low specimen volumes limited our ability to fully resolve discrepant results.

  3. Evolution of environmental impact assessment as applied to watershed modification projects in Canada

    NASA Astrophysics Data System (ADS)

    Dirschl, Herman J.; Novakowski, Nicholas S.; Sadar, M. Husain

    1993-07-01

    This article reviews the application of environmental impact assessment (EIA) procedures and practices to three watershed modification projects situaled in western Canada. These ventures were justified for accelerating regional economic development, and cover the period during which public concerns for protecting the environment rapidly made their way into the national political agenda. An historical account and analysis of the situation, therefore, seems desirable in order to understand the development of EIA processes, practices, and methodologies since the start of construction of the first project in 1961. This study concludes that there has been good progress in predicting and evaluating environmental and related social impacts of watershed modification proposals. However, a number of obstacles need to be overcome before EIA can firmly establish itself as an effective planning tool. These difficulties include jurisdictional confusions and conflicts, division of authority and responsibility in designing and implementing appropriate mitigative and monitoring measures, lack of tested EIA methodologies, and limited availability of qualified human resources. A number of conclusions and suggestions are offered so that future watershed modification proposals may be planned and implemented in a more environmentally sustainable fashion. These include: (1) EIA processes must be completed before irrevocable decisions are made. (2) Any major intrusion into a watershed is likely to impact on some major components of the ecosystem(s). (3) Mitigation costs must form part of the benefit-cost analysis of any project proposal. (4) Interjurisdictional cooperation is imperative where watersheds cross political boundaries. (5) The EIA process is a public process, hence public concerns must be dealt with fairly. (6) The role of science in the EIA process must be at arms length from project proponents and regulators, and allowed to function in the interest of the protection of the environment and public health and safety.

  4. Simultaneous immobilization of glucose oxidase on the surface and cavity of hollow gold nanospheres as labels for highly sensitive electrochemical immunoassay of tumor marker.

    PubMed

    Song, Zhongju; Yuan, Ruo; Chai, Yaqin; Jiang, Wen; Su, Huilan; Che, Xin; Ran, Xiaoqi

    2011-01-15

    A novel tracer, glucose oxidase (GOD)-functionalized hollow gold nanospheres encapsulating glucose oxidase (Au(shell)@GOD), was designed to label the ferrocenemonocarboxylic-grafted secondary antibodies (Fc@Ab(2)) for highly sensitive detection of tumor marker using carboxyl group functionalized multiwall carbon nanotubes as platform. Initially, Au(shell)@GOD was synthesized specially by reverse micelle approach, and then the labeling of antibody and the preparation of GOD-functionalized Au(shell)@GOD were performed by one-pot assembly of Fc@Ab(2) and GOD on the surface of Au(shell)@GOD. The ferrocene used to label antibodies acted as a mediator of electron transfer between GOD and electrode surface. The high-content glucose oxidase in the tracer (on the surface and in the cavity) could significantly amplify the amperometric signal for sandwich-type immunoassay. Using carcinoembryonic antigen (CEA) as model analyte, the designed tracer showed linear range from 0.02 to 5.0 ng mL(-1) with the detection limit down to 6.7 pg mL(-1). The assay results of serum samples with the proposed method were in an acceptable agreement with the reference values. The new protocol showed acceptable stability and reproducibility, high sensitivity, and good precision, which could provide a promising potential for clinical screening and diagnosis of tumor disease. Copyright © 2010 Elsevier B.V. All rights reserved.

  5. Investigating Perturbation Electric Fields and Their Effects on the Coupled Low-, Mid- and High-latitude Ionosphere

    DTIC Science & Technology

    2015-08-14

    stream (SAPS) E field had been strong. During these E field events, the repeated development of equatorial ionization anomaly ( EIA ), storm-enhanced...density (SED) bulge and SED plume occurred in those longitude sectors that covered the local dusk-midnight hours. Thus, a well-formed EIA - SED...Observational results and CTIPe simulated wind vector maps suggest that 1) the enhanced growth of the EIA transported solar produced plasma to the

  6. Serologic test systems development. Progress report, October 1, 1978-September 30, 1979

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seawright, G.L.; Sanders, W.M.; Hollstein, U.

    1980-12-01

    Work has continued on the development and automation of enzyme immunoassays (EIA) for detecting diseases and toxic agents in food animals. Further evaluations were made of the Technicon Autoanalyzer II(AAII) for conducting totally automated EIAs. The problems investigated were machine carryover and assay variation. Modifications greatly reduced or eliminated carryover and produced acceptable levels of test variation. The EIA for swine trichinosis was significantly improved by the use of a new, partially purified antigen preparation. The result was improved detection of early seroconversions and reduced probability for false negatives and false positives. The amplified EIA was adapted as a diagnosticmore » test for bovine brucellosis and studies were initiated for differentiating vaccinated and infected animals. Preliminary data indicate that the IgG/sub 1/ response may be diagnostic but further studies are necessary. Development of the EIA for detecting low molecular weight contaminants and residues in food products was also initiated. Compounds studied were the antibiotics chloramphenicol, tetracycline, and gentamicin; the mycotoxin, aflatoxin, and the shale oil toxin, 2-aminofluorene. Results indicate that chloramphenicol nonspecifically binds to antibody and interferes with antibody activity. Thus, the test is not yet satisfactory. Initial attempts to automate the gentamicin test were unsuccessful because of machine carryover but modifications of the AAII have produced encouraging preliminary data. Work is continuing on the development of EIAs for all of the compounds mentioned above. (ERB)« less

  7. The validation and utility of a quantitative one-step multiplex RT real-time PCR targeting Rotavirus A and Norovirus

    PubMed Central

    Dung, Tran Thi Ngoc; Phat, Voong Vinh; Nga, Tran Vu Thieu; My, Phan Vu Tra; Duy, Pham Thanh; Campbell, James I.; Thuy, Cao Thu; Hoang, Nguyen Van Minh; Van Minh, Pham; Le Phuc, Hoang; Tuyet, Pham Thi Ngoc; Vinh, Ha; Kien, Duong Thi Hue; Huy, Huynh Le Anh; Vinh, Nguyen Thanh; Nga, Tran Thi Thu; Hau, Nguyen Thi Thu; Chinh, Nguyen Tran; Thuong, Tang Chi; Tuan, Ha Manh; Simmons, Cameron; Farrar, Jeremy J.; Baker, Stephen

    2013-01-01

    Rotavirus (RoV) and Norovirus (NoV) are the main causes of viral gastroenteritis. Currently, there is no validated multiplex real-time PCR that can detect and quantify RoV and NoV simultaneously. The aim of the study was to develop, validate, and internally control a multiplex one-step RT real-time PCR to detect and quantify RoV and NoV in stool samples. PCR sensitivity was assessed by comparing amplification against the current gold standard, enzyme immunoassay (EIA), on stool samples from 94 individuals with diarrhea and 94 individuals without diarrhea. PCR detected 10% more RoV positive samples than EIA in stools samples from patients with diarrhea. PCR detected 23% more NoV genogroup II positive samples from individuals with diarrhea and 9% more from individuals without diarrhea than EIA, respectively. Genotyping of the PCR positive/EIA negative samples suggested the higher rate of PCR positivity, in comparison to EIA, was due to increased sensitivity, rather than nonspecific hybridization. Quantitation demonstrated that the viral loads of RoV and NoV in the stools of diarrheal patients were an order of magnitude greater than in individuals without diarrhea. This internally controlled real-time PCR method is robust, exhibits a high degree of reproducibility, and may have a greater utility and sensitivity than commercial EIA kits. PMID:23046990

  8. Health Impact Assessment Practice and Potential for Integration within Environmental Impact and Strategic Environmental Assessments in Italy

    PubMed Central

    Linzalone, Nunzia; Assennato, Giorgio; Ballarini, Adele; Cadum, Ennio; Cirillo, Mario; Cori, Liliana; De Maio, Francesca; Musmeci, Loredana; Natali, Marinella; Rieti, Sabrina; Soggiu, Maria Eleonora; Bianchi, Fabrizio

    2014-01-01

    Avoiding or minimizing potential environmental impact is the driving idea behind protecting a population’s health via Environmental Impact Assessments (EIAs) and Strategic Environmental Assessments (SEAs). However, both are often carried out without any systematic approach. This paper describes the findings of a review of HIA, EIA and SEA experiences carried out by the authors, who act as institutional competent subjects at the national and regional levels in Italy. The analysis of how health is tackled in EIA and SEA procedures could support the definition of a protocol for the integration of HIA with EIA and SEA. Although EIA and SEA approaches include the aim of protecting health, significant technical and methodological gaps are present when assessing health systematically, and their basic principles regarding assessment are unsatisfactory for promoting and addressing healthcare concepts stated by the WHO. HIA is still poorly integrated into the decision-making process, screening and monitoring phases are only occasionally implemented, and operational details are not well-defined. The collaborative approach of institutions involved in environment and health is a core element in a systematic advancement toward supporting effective decisions and effective protection of the environment and health. At the Italian national level, the definition of guidelines and tools for HIA, also in relation with EIA and SEA, is of great interest. PMID:25493391

  9. Quality control and the substantive influence of environmental impact assessment in Finland

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poeloenen, Ismo

    2006-07-15

    This paper focuses on the challenges concerning the quality assurance of environmental impact statements (EIS) in Finland and the European Union. Moreover, the linkage between environmental impact assessment and decision-making is examined from a legal point of view. In addition, the paper includes some comparative remarks concerning the content requirements of examination of alternatives. The study reveals that a significant problem of the Finnish EIA system is the lack of efficient access to a judicial procedure to challenge the quality and completeness of an EIS. Another pitfall is the fact that in certain permit procedures, environmental consideration is so limitedmore » that only a minor part of the EIA can be taken into account. In its current state, EIA legislation in the EU and in Finland does not guarantee that the assessment results filter into decision-making. From the national point of view, the shortcomings can be addressed by amending current legislation concerning licensing procedures so that authorities have the competence and the duty to take environmental matters widely into account in the permit consideration. At the European level, a legislative alternative could be to strengthen the substantive element of the EIA Directive (85/337/EEC). This would increase the weight of EIA related arguments in the national appellate procedures and contribute, in some cases significantly, to the substantive influence of EIA in decision-making.« less

  10. Christmas-tree Derived Amplification Immuno-strategy for Sensitive Visual Detection of Vibrio parahaemolyticus Based on Gold Label Silver Stain Technology.

    PubMed

    Song, Xinxin; Wu, Yanjie; Wu, Lin; Hu, Yufang; Li, Wenrou; Guo, Zhiyong; Su, Xiurong; Jiang, Xiaohua

    2017-01-01

    A developed Christmas-tree derived immunosensor based on a gold label silver stain (GLSS) technique was fabricated for a highly sensitive analysis of Vibrio parahaemolyticu (VP). In this strategy, captured VP antibody (cAb) was immobilized on a solid substrate; then, the VPs were sequentially tagged with a signal probe by incubating the assay with a detection VP antibody (dAb) conjugated gold nanoparticles (AuNPs)-labeled graphite-like carbon nitride (g-C 3 N 4 ). Finally, the attached signal probe could harvest a visible signal by the silver meal deposition, and then followed by homebrew Matlab 6.0 as a grey value acquisition. In addition, the overall design of the biosensor was established in abundant AuNPs and g-C 3 N 4 with a two-dimensional structure, affording a bulb-decorated Christmas-tree model. Moreover, with the optimized conditions, the detection limit of the as-proposed biosensor is as low as 10 2 CFU (Colony-Forming Units) mL -1 , exhibiting an increase of two orders of magnitude compared with the traditional immune-gold method. Additionally, the developed visible immunosensor was also successfully applied to the analysis of complicated samples.

  11. Assessing Health Impacts within Environmental Impact Assessments: An Opportunity for Public Health Globally Which Must Not Remain Missed

    PubMed Central

    Harris, Patrick; Viliani, Francesca; Spickett, Jeff

    2015-01-01

    Within the member states of the United Nations 190 of 193 have regulated Environmental Impact Assessments (EIA) which is a systematic process to prevent and mitigate the potential environmental impacts of industry development projects before these occur. However, the routine and comprehensive assessment of health impacts within EIAs remains underdeveloped. Focusing, as an example, on the risks to global health from the global shift in the mining industry towards Low and Middle Income Countries LMIC), this viewpoint details why connecting with EIA is an essential task for the health system. Although existing knowledge is out of date in relation to global practice we identify how health has been included, to some extent, in High Income Country EIAs and the institutional requirements for doing so. Using arguments identified by industry themselves about requiring a ‘social license to operate’, we conclude that EIA regulations provide the best current mechanism to ensure health protection is a core aspect in the decision making process to approve projects. PMID:25608592

  12. Transboundary EIA: Iberian experiences

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Albergaria, Rita; Fidelis, Teresa

    2006-10-15

    The 1314 km border shared by Portugal and Spain is simultaneously a conflict generator, due to joint access to common resources such as water, and a motive for transboundary cooperation in terms of development projects based on common concerns. Transboundary cooperation associated with Environment Impact Assessment (EIA) has been encouraged through the enactment of the Espoo Convention (1997). The European Union has adopted a Directive (97/11/CE Directive) under which taking transboundary impacts into consideration during EIA processes has become mandatory for member states. As a consequence, Portugal and Spain have approved related provisions. This paper aims to critically analyse themore » legal and procedural features of bilateral cooperation through the comparison of two case studies related to water management projects (the Sela and Alqueva dams). The paper highlights procedural weaknesses and puts forward a 'Good Practice Model' for cooperation under transboundary EIA processes. The model focuses on the ways in which EIA-based bilateral cooperation should proceed through the specification of phases and procedures for collaboration between Portugal and Spain in the identification and evaluation of transboundary impacts, as well in the public participation procedures.« less

  13. Immunochemical Analysis of Paxilline and Ergot Alkaloid Mycotoxins in Grass Seeds and Plants.

    PubMed

    Bauer, Julia I; Gross, Madeleine; Cramer, Benedikt; Humpf, Hans-Ulrich; Hamscher, Gerd; Usleber, Ewald

    2018-01-10

    Limited availability of toxin standards for lolitrem B and ergovaline impedes routine control of grasses for endophyte toxins. This study aimed at assessing the applicability of an enzyme immunoassay (EIA) for the indole-diterpene mycotoxin paxilline, in combination with a generic EIA for ergot alkaloids, as alternative parameters for screening purposes. Analysis of grass seeds and model pastures of four different grass species showed that both EIAs yielded highly positive results for paxilline and ergot alkaloids in perennial ryegrass seeds. Furthermore, evidence for natural occurrence of paxilline in grass in Germany was obtained. High performance liquid chromatography-tandem mass spectrometry analysis qualitatively confirmed the paxilline EIA results but showed that paxilline analogues 1'-O-acetylpaxilline and 13-desoxypaxilline were the predominant compounds in seeds and grass. In the absence of easily accessible reference standards for specific analysis of some major endophyte toxins, analysis of paxilline and ergot alkaloids by EIA may be suitable substitute parameters. The major advantage of this approach is its ease of use and speed, providing an analytical tool which could enhance routine screening for endophyte toxins in pasture.

  14. A proposal to improve ecological compensation practice in road and railway projects in Spain

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Villarroya, Ana, E-mail: avillarroya@alumni.unav.es; Puig, Jordi, E-mail: jpbaguer@unav.es

    2013-09-15

    To reduce ecological impacts caused by development projects, avoidance, minimization and compensation techniques have to be taken together into consideration along Environmental Impact Assessment (EIA) procedures. This paper explores the particular role that ecological compensation has had in recent road and railway EIA procedures in Spain, as seen through the review of a set of recent EIA Records of Decision (RODs) that confirms precedent findings. Noticing that residual impacts are not paid much attention, and that there is no evidence of a solid public participation in ecological impact evaluation, it proposes to increase the awareness on residual impacts, as amore » way to make easier public access to the allegedly most sensitive moment of EIA implementation: (residual) impact evaluation. -- Highlights: ► Ecological compensation practice in Spain is much lower than avoidance or mitigation. ► Residual impacts are overlooked in EIA processes and public participation is low. ► An increased awareness of residual impacts may also promote public participation. ► Current context needs these small steps to move towards better compensation practice.« less

  15. Issues in midterm analysis and forecasting 1998

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1998-07-01

    Issues in Midterm Analysis and Forecasting 1998 (Issues) presents a series of nine papers covering topics in analysis and modeling that underlie the Annual Energy Outlook 1998 (AEO98), as well as other significant issues in midterm energy markets. AEO98, DOE/EIA-0383(98), published in December 1997, presents national forecasts of energy production, demand, imports, and prices through the year 2020 for five cases -- a reference case and four additional cases that assume higher and lower economic growth and higher and lower world oil prices than in the reference case. The forecasts were prepared by the Energy Information Administration (EIA), using EIA`smore » National Energy Modeling System (NEMS). The papers included in Issues describe underlying analyses for the projections in AEO98 and the forthcoming Annual Energy Outlook 1999 and for other products of EIA`s Office of Integrated Analysis and Forecasting. Their purpose is to provide public access to analytical work done in preparation for the midterm projections and other unpublished analyses. Specific topics were chosen for their relevance to current energy issues or to highlight modeling activities in NEMS. 59 figs., 44 tabs.« less

  16. Dissecting linear and conformational epitopes on the native thyrotropin receptor.

    PubMed

    Ando, Takao; Latif, Rauf; Daniel, Samira; Eguchi, Katsumi; Davies, Terry F

    2004-11-01

    The TSH receptor (TSHR) is the primary antigen in Graves' disease. In this condition, autoantibodies to the TSHR that have intrinsic thyroid-stimulating activity develop. We studied the epitopes on the native TSHR using polyclonal antisera and monoclonal antibodies (mAbs) derived from an Armenian hamster model of Graves' disease. Of 14 hamster mAbs analyzed, five were shown to bind to conformational epitopes including one mAb with potent thyroid-stimulating activity. Overlapping conformational epitopes were determined by cell-binding competition assays using fluorescently labeled mAbs. We identified two distinct conformational epitopes: epitope A for both stimulating and blocking mAbs and epitope B for only blocking mAbs. Examination of an additional three mouse-derived stimulating TSHR-mAbs also showed exclusive binding to epitope A. The remaining nine hamster-derived mAbs were neutral or low-affinity blocking antibodies that recognized linear epitopes within the TSHR cleaved region (residues 316-366) (epitope C). Serum from the immunized hamsters also recognized conformational epitopes A and B but, in addition, also contained high levels of TSHR-Abs interacting within the linear epitope C region. In summary, these studies indicated that the natively conformed TSHR had a restricted set of epitopes recognized by TSHR-mAbs and that the binding site for stimulating TSHR-Abs was highly conserved. However, high-affinity TSHR-blocking antibodies recognized two conformational epitopes, one of which was indistinguishable from the thyroid-stimulating epitope. Hence, TSHR-stimulating and blocking antibodies cannot be distinguished purely on the basis of their conformational epitope recognition.

  17. PET Imaging of Macrophage Mannose Receptor-Expressing Macrophages in Tumor Stroma Using 18F-Radiolabeled Camelid Single-Domain Antibody Fragments.

    PubMed

    Blykers, Anneleen; Schoonooghe, Steve; Xavier, Catarina; D'hoe, Kevin; Laoui, Damya; D'Huyvetter, Matthias; Vaneycken, Ilse; Cleeren, Frederik; Bormans, Guy; Heemskerk, Johannes; Raes, Geert; De Baetselier, Patrick; Lahoutte, Tony; Devoogdt, Nick; Van Ginderachter, Jo A; Caveliers, Vicky

    2015-08-01

    Tumor-associated macrophages constitute a major component of the stroma of solid tumors, encompassing distinct subpopulations with different characteristics and functions. We aimed to identify M2-oriented tumor-supporting macrophages within the tumor microenvironment as indicators of cancer progression and prognosis, using PET imaging. This can be realized by designing (18)F-labeled camelid single-domain antibody fragments (sdAbs) specifically targeting the macrophage mannose receptor (MMR), which has been identified as an important biomarker on this cell population. Cross-reactive anti-MMR sdAbs were generated after immunization of an alpaca with the extracellular domains of both human and mouse MMR. The lead binder was chosen on the basis of comparisons of binding affinity and in vivo pharmacokinetics. The PET tracer (18)F-fluorobenzoate (FB)-anti-MMR sdAb was developed using the prosthetic group N-succinimidyl-4-(18)F-fluorobenzoate ((18)F-SFB), and its biodistribution, tumor-targeting potential, and specificity in terms of macrophage and MMR targeting were evaluated in mouse tumor models. Four sdAbs were selected after affinity screening, but only 2 were found to be cross-reactive for human and mouse MMR. The lead anti-MMR 3.49 sdAb, bearing an affinity of 12 and 1.8 nM for mouse and human MMR, respectively, was chosen for its favorable in vivo biodistribution profile and tumor-targeting capacity. (18)F-FB-anti-MMR 3.49 sdAb was synthesized with a 5%-10% radiochemical yield using an automated and optimized protocol. In vivo biodistribution analyses showed fast clearance via the kidneys and retention in MMR-expressing organs and tumor. The kidney retention of the fluorinated sdAb was 20-fold lower than a (99m)Tc-labeled counterpart. Compared with MMR- and C-C chemokine receptor 2-deficient mice, significantly higher uptake was observed in tumors grown in wild-type mice, demonstrating the specificity of the (18)F tracer for MMR and macrophages, respectively. Anti-MMR 3.49 was denoted as the lead cross-reactive MMR-targeting sdAb. (18)F radiosynthesis was optimized, providing an optimal probe for PET imaging of the tumor-promoting macrophage subpopulation in the tumor stroma. © 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  18. Wheezing or Breezing through Exercise-Induced Asthma.

    ERIC Educational Resources Information Center

    McCarthy, Paul

    1989-01-01

    Several physicians discuss the tests they use to diagnose exercise-induced asthma (EIA), the medications they typically prescribe and why, and the importance of properly educating athletes about EIA. (JD)

  19. Selective disulfide reduction for labeling and enhancement of Fab antibody fragments.

    PubMed

    Kirley, Terence L; Greis, Kenneth D; Norman, Andrew B

    2016-11-25

    Many methods have been developed for chemical labeling and enhancement of the properties of antibodies and their common fragments, including the Fab and F(ab') 2 fragments. Somewhat selective reduction of some antibody disulfide bonds has been previously achieved, yielding antibodies and antibody fragments that can be labeled at defined sites, enhancing their utility and properties. Selective reduction of the two hinge disulfide bonds present in F(ab') 2 fragments using mild reduction has been useful. However, such reduction is often not quantitative and results in the reduction of multiple disulfide bonds, and therefore subsequent multiple labeling or conjugation sites are neither homogenous nor stoichiometric. Here, a simple and efficient selective reduction of the single disulfide bond linking the partial heavy chain and the intact light chain which compose the Fab fragment is accomplished utilizing tris(2-carboxyethyl)phosphine (TCEP) immobilized on agarose beads. The resultant reduced cysteine residues were labeled with several cysteine-selective fluorescent reagents, as well as by cysteine-directed PEGylation. These two cysteine residues can also be re-ligated by means of a bifunctional cysteine cross-linking agent, dibromobimane, thereby both restoring a covalent linkage between the heavy and light chains at this site, far removed from the antigen binding site, and also introducing a fluorescent probe. There are many other research and clinical uses for these selectively partially reduced Fab fragments, including biotinylation, toxin and drug conjugation, and incorporation of radioisotopes, and this technique enables simple generation of very useful Fab fragment derivatives with many potential applications. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Evaluation of Non-Lethal Effects of N2 Bubbles on Marine Mammal Health and the Potential Role of Immune Activity in Facilitating the Development of Dive Related Injury

    DTIC Science & Technology

    2015-09-30

    control for confounding effects of changing physiological status. Cortisol will be measured using a commercial enzyme immunoassay ( EIA ) and plasma...complement activity in plasma and serum has been tested using zymosan (Sigma Aldrich) which is a known activator of complement. Validation of the EIA ...expected to be underway by November 2015. Data collection for objective 3 will occur during project year 2. RESULTS EIA kits for seal

  1. Identical genomic footprints of the adenovirus EIIa promoter are detected before and after EIa induction.

    PubMed Central

    Devaux, B; Albrecht, G; Kedinger, C

    1987-01-01

    Genomic DNase I footprinting was used to compare specific protein binding to the adenovirus type 5 early, EIa-inducible, EIIa promoter. Identical protection patterns of the promoter region were observed whether EIIa transcription was undetectable or fully induced. These results suggest that EIa-mediated transcriptional induction does not increase binding of limiting transcription factors to the promoter but rather that transactivation results from the proper interactions between factors already bound to their cognate sequences. Images PMID:2963956

  2. An Assessment of EIA's Building Consumption Data

    EIA Publications

    2012-01-01

    The U.S. Energy Information Administration (EIA) routinely uses feedback from customers and outside experts to help improve its programs and products. As part of an assessment of its consumption surveys, EIA reached out to the National Academy of Sciences' Committee on National Statistics (CNSTAT) asking them to assess the Commercial Buildings Energy Consumption Survey (CBECS) and the Residential Energy Consumption Survey (RECS) and recommend improvements in data quality, geographic coverage, timeliness of data releases, and relevance of data for users.

  3. In Vitro and In Vivo Analysis of Indocyanine Green-Labeled Panitumumab for Optical Imaging—A Cautionary Tale

    PubMed Central

    2015-01-01

    Indocyanine green (IC-Green), the only FDA approved near-infrared (NIR) fluorophore for clinical use, is attractive to researchers for the development of targeted optical imaging agents by modification of its structure and conjugation to monoclonal antibodies (mAbs) or their fragments. IC-Green derivative, ICG-sulfo-OSu (ICG-sOSu), is frequently used for antibody conjugation. However, ICG-sOSu is amphiphilic and readily facilitates aggregation of mAbs that is not easily separable from the desired immunoconjugates. Complications originating from this behavior are frequently overlooked by researchers. This study examined detailed chemical and biological characteristics of an ICG-sOSu-labeled mAb, panitumumab, and provided a clinically applicable strategy to deliver a pure conjugation product. Size-exclusion high-performance liquid chromatography (SE-HPLC) analysis of conjugation reactions, performed at molar reaction ratios of ICG-sOSu: mAb of 5, 10, or 20, resulted in isolable desired ICG-sOSu-panitumumab conjugation product in 72%, 53%, and 19% yields, respectively, with the remainder consisting of high molecular weight aggregates (>150 kDa) 14%, 30%, and 51%, respectively. The HPLC-purified ICG-sOSu-panitumumab products were analyzed by native and SDS polyacrylamide gel electrophoresis (PAGE) followed by optical imaging. Results indicated that the interaction between ICG-sOSu and panitumumab was due to both covalent and noncovalent binding of the ICG-sOSu to the protein. Noncovalently bound dye in the ICG-sOSu-panitumumab conjugate products was removed by extraction with ethyl acetate to further purify the HPLC-isolated conjugation products. With conserved immunoreactivity, excellent target-specific uptake of the doubly purified bioconjugates was observed with minimal liver retention in athymic nude mice bearing HER1-expressing tumor xenografts. In summary, the preparation of well-defined bioconjugate products labeled with commercial ICG-sOSu dye is not a simple process and control of the conjugation reaction ratio and conditions is crucial. Furthermore, absolute purification and characterization of the products is necessitated prior to in vivo optical imaging. Use of validated and characterized dye conjugate products should facilitate the development of clinically viable and reproducible IC-Green derivative and other NIR dye mAb conjugates for optical imaging applications. PMID:25243604

  4. In vitro and in vivo analysis of indocyanine green-labeled panitumumab for optical imaging-a cautionary tale.

    PubMed

    Zhou, Yang; Kim, Young-Seung; Milenic, Diane E; Baidoo, Kwamena E; Brechbiel, Martin W

    2014-10-15

    Indocyanine green (IC-Green), the only FDA approved near-infrared (NIR) fluorophore for clinical use, is attractive to researchers for the development of targeted optical imaging agents by modification of its structure and conjugation to monoclonal antibodies (mAbs) or their fragments. IC-Green derivative, ICG-sulfo-OSu (ICG-sOSu), is frequently used for antibody conjugation. However, ICG-sOSu is amphiphilic and readily facilitates aggregation of mAbs that is not easily separable from the desired immunoconjugates. Complications originating from this behavior are frequently overlooked by researchers. This study examined detailed chemical and biological characteristics of an ICG-sOSu-labeled mAb, panitumumab, and provided a clinically applicable strategy to deliver a pure conjugation product. Size-exclusion high-performance liquid chromatography (SE-HPLC) analysis of conjugation reactions, performed at molar reaction ratios of ICG-sOSu: mAb of 5, 10, or 20, resulted in isolable desired ICG-sOSu-panitumumab conjugation product in 72%, 53%, and 19% yields, respectively, with the remainder consisting of high molecular weight aggregates (>150 kDa) 14%, 30%, and 51%, respectively. The HPLC-purified ICG-sOSu-panitumumab products were analyzed by native and SDS polyacrylamide gel electrophoresis (PAGE) followed by optical imaging. Results indicated that the interaction between ICG-sOSu and panitumumab was due to both covalent and noncovalent binding of the ICG-sOSu to the protein. Noncovalently bound dye in the ICG-sOSu-panitumumab conjugate products was removed by extraction with ethyl acetate to further purify the HPLC-isolated conjugation products. With conserved immunoreactivity, excellent target-specific uptake of the doubly purified bioconjugates was observed with minimal liver retention in athymic nude mice bearing HER1-expressing tumor xenografts. In summary, the preparation of well-defined bioconjugate products labeled with commercial ICG-sOSu dye is not a simple process and control of the conjugation reaction ratio and conditions is crucial. Furthermore, absolute purification and characterization of the products is necessitated prior to in vivo optical imaging. Use of validated and characterized dye conjugate products should facilitate the development of clinically viable and reproducible IC-Green derivative and other NIR dye mAb conjugates for optical imaging applications.

  5. Carbon dots based immunosorbent assay for the determination of GFAP in human serum

    NASA Astrophysics Data System (ADS)

    Ma, Yunsu; Xu, Guanhong; Wei, Fangdi; Cen, Yao; Song, Yueyue; Ma, Yujie; Xu, Xiaoman; Shi, Menglan; Sohail, Muhammad; Hu, Qin

    2018-04-01

    Glial fibrillary acidic protein (GFAP) is expressed in the central nervous system and the level of GFAP normally rises with brain injury and astroglial tumors. So, serum GFAP is used as a marker for diagnosing various types of brain damage and astroglial tumors. In this study, a new sensor based on carbon dots (CDs) linked with antibodies to specifically detect GFAP in human serum was developed. Anti-GFAP (Ab1) linked with protein A/G agarose resin (PA/G) as a capture antibody (PA/G-Ab1) and anti-GFAP (Ab2) labeled with CDs as a detection antibody (CDs-Ab2) were prepared firstly. Then the CD-linked antibody immunosorbent assay (CLAISA) method was constructed based on the sandwich conjunction reaction among PA/G-Ab1, GFAP, and CDs-Ab2. CLAISA, using the fluorescence of PA/G-Ab1-GFAP-Ab2-CDs as the direct signal, enabled the proposed immunosensor to detect GFAP sensitively with a linear range of 0.10-8.00 ng ml-1 and a detection limit of 25 pg ml-1. This method was applied to the determination of GFAP in human serum by the standard addition method, and the results showed high accuracy and precision. Considering the easy synthetic process and excellent performance of CLAISA, this method has great potential to be used to monitor GFAP in the clinic.

  6. Comparison of Premier CAMPY Enzyme Immunoassay (EIA), ProSpecT Campylobacter EIA, and ImmunoCard STAT! CAMPY Tests with Culture for Laboratory Diagnosis of Campylobacter Enteric Infections ▿ †

    PubMed Central

    Granato, Paul A.; Chen, Li; Holiday, Iris; Rawling, Russell A.; Novak-Weekley, Susan M.; Quinlan, Tammy; Musser, Kimberlee A.

    2010-01-01

    Campylobacter enteritis is a food-borne or waterborne illness caused almost exclusively by Campylobacter jejuni and, to a lesser extent, by Campylobacter coli. These organisms produce indistinguishable clinical diseases and together represent the second most common cause of bacterial diarrhea in the United States and the leading cause of enteric infection throughout the world. The conventional approach to the laboratory diagnosis of Campylobacter enteritis is based on the recovery of the organism from a stool specimen, which requires the use of a specialized medium incubated at 42°C for several days in an artificially created microaerophilic environment. Recently, several commercially available enzyme immunoassays (EIAs) have been developed for the direct detection of C. jejuni and C. coli in stool specimens. This study compared conventional culture with three EIA methods, the Premier CAMPY EIA (Meridian Bioscience, Cincinnati, OH), the ProSpecT Campylobacter EIA (Remel, Lenexa, KS), and the ImmunoCard STAT! CAMPY test (Meridian Bioscience, Cincinnati, OH), for the detection of C. jejuni and C. coli in 485 patient stool samples. Discordant results were arbitrated by using an in-house, real-time PCR assay that was developed and validated by a public health reference laboratory. Following analyses of the discrepant specimens by PCR, the sensitivity and specificity of both the Premier CAMPY and ProSpecT Campylobacter EIAs were 99.3% and 98%, respectively, while the ImmunoCard STAT! CAMPY test had a sensitivity of 98.5% and a specificity of 98.2%. By use of the PCR test as the reference standard, culture detected 127 of 135 Campylobacter-positive stool specimens, yielding a sensitivity of 94.1%. These results showed that the three EIAs evaluated in this study provide a rapid and reliable alternative for the laboratory diagnosis of enteric infections with C. jejuni and C. coli and that conventional culture may no longer be recognized as the “gold standard” for diagnosis. PMID:20810765

  7. Identification of Past and Recent Parvovirus B19 Infection in Immunocompetent Individuals by Quantitative PCR and Enzyme Immunoassays: a Dual-Laboratory Study

    PubMed Central

    Hedman, Lea; Dhanilall, Pravesh; Kantola, Kalle; Nurmi, Visa; Söderlund-Venermo, Maria; Brown, Kevin E.; Hedman, Klaus

    2014-01-01

    Parvovirus B19 (B19V) is a member of the family Parvoviridae, genus Erythrovirus. B19V-specific IgG and IgM react differently against conformational and linear epitopes of VP1 and VP2 antigens, leading to the development of IgG avidity and epitope type specificity (ETS) enzyme immunoassays (EIAs) for distinguishing past from recent infection. Additionally, B19V viral load determination (by quantitative PCR [qPCR]) is increasingly used in the staging of B19V infection. In this study, the utility of these methods is compared. A panel of 78 sera was jointly tested by the Virus Reference Department (VRD), London, United Kingdom, and the Haartman Institute (HI), Helsinki, Finland, using a number of EIAs, e.g., B19V-specific IgG and IgM, IgG avidity, and ETS EIAs. At VRD, the sera were also tested by a B19V viral load PCR (qPCR). By consensus analysis, 43 (55.1%) sera represented past infection, 28 (35.9%) sera represented recent infection, and 7 (9.0%) sera were indeterminate. Both VRD B19V qPCR and HI B19V VP2 IgM EIA gave the highest agreement with consensus interpretation for past or recent infection, with an overall agreement of 99% (95% confidence interval [CI], 92 to 100) and positive predictive value (PPV) of 100% (95% CI, 87 to 100). Nine sera designated as representing past infection by consensus analysis were B19V IgM positive by a commercial VRD B19V IgM EIA and B19V IgM negative by a new HI in-house B19V VP2 IgM EIA. A new VRD B19V IgG avidity EIA showed good (>95%) agreement (excluding equivocal results) with consensus interpretations for past or recent infection. Correct discrimination of past from recent B19V infection was achieved through application of qPCR or by appropriate selection of EIAs. PMID:24403307

  8. Electron detachment dissociation of fluorescently labeled sialylated oligosaccharides.

    PubMed

    Zhou, Wen; Håkansson, Kristina

    2011-12-01

    We explored the application of electron detachment dissociation (EDD) and infrared multiphoton dissociation (IRMPD) tandem mass spectrometry to fluorescently labeled sialylated oligosaccharides. Standard sialylated oligosaccharides and a sialylated N-linked glycan released from human transferrin were investigated. EDD yielded extensive glycosidic cleavages and cross-ring cleavages in all cases studied, consistently providing complementary structural information compared with infrared multiphoton dissociation. Neutral losses and satellite ions such as C-2H ions were also observed following EDD. In addition, we examined the influence of different fluorescent labels. The acidic label 2-aminobenzoic acid (2-AA) enhanced signal abundance in negative-ion mode. However, few cross-ring fragments were observed for 2-AA-labeled oligosaccharides. The neutral label 2-aminobenzamide (2-AB) resulted in more cross-ring cleavages compared with 2-AA-labeled species, but not as extensive fragmentation as for native oligosaccharides, likely resulting from altered negative charge locations from introduction of the fluorescent tag. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Single domain antibody-quantum dot conjugates for ricin detection by both fluoroimmunoassay and surface plasmon resonance.

    PubMed

    Anderson, George P; Glaven, Richard H; Algar, W Russ; Susumu, Kimihiro; Stewart, Michael H; Medintz, Igor L; Goldman, Ellen R

    2013-07-05

    The combination of stable biorecognition elements and robust quantum dots (QDs) has the potential to yield highly effective reporters for bioanalyses. Llama-derived single domain antibodies (sdAb) provide small thermostable recognition elements that can be easily manipulated using standard DNA methods. The sdAb was self-assembled on dihydrolipoic acid (DHLA) ligand-capped CdSe-ZnS core-shell QDs made in our laboratory through the polyhistidine tail of the protein, which coordinated to zinc ions on the QD surface. The sdAb-QD bioconjugates were then applied in both fluorometric and surface plasmon resonance (SPR) immunoassays for the detection of ricin, a potential biothreat agent. The sdAb-QD conjugates functioned in fluoroimmunoassays for the detection of ricin, providing equivalent limits of detection when compared to the same anti-ricin sdAb labeled with a conventional fluorophore. In addition, the DHLA-QD-sdAb conjugates were very effective reporter elements in SPR sandwich assays, providing more sensitive detection with a signal enhancement of ~10-fold over sdAb reporters and 2-4 fold over full sized antibody reporters. Commercially prepared streptavidin-modified polymer-coated QDs also amplified the SPR signal for the detection of ricin when applied to locations where biotinylated anti-ricin sdAb was bound to target; however, we observed a 4-fold greater amplification when using the DHLA-QD-sdAb conjugates in this format. Copyright © 2013. Published by Elsevier B.V.

  10. ImmunoPET/MR imaging allows specific detection of Aspergillus fumigatus lung infection in vivo

    PubMed Central

    Rolle, Anna-Maria; Hasenberg, Mike; Thornton, Christopher R.; Solouk-Saran, Djamschid; Männ, Linda; Weski, Juliane; Maurer, Andreas; Fischer, Eliane; Spycher, Philipp R.; Schibli, Roger; Boschetti, Frederic; Stegemann-Koniszewski, Sabine; Bruder, Dunja; Severin, Gregory W.; Autenrieth, Stella E.; Krappmann, Sven; Davies, Genna; Pichler, Bernd J.; Gunzer, Matthias; Wiehr, Stefan

    2016-01-01

    Invasive pulmonary aspergillosis (IPA) is a life-threatening lung disease caused by the fungus Aspergillus fumigatus, and is a leading cause of invasive fungal infection-related mortality and morbidity in patients with hematological malignancies and bone marrow transplants. We developed and tested a novel probe for noninvasive detection of A. fumigatus lung infection based on antibody-guided positron emission tomography and magnetic resonance (immunoPET/MR) imaging. Administration of a [64Cu]DOTA-labeled A. fumigatus-specific monoclonal antibody (mAb), JF5, to neutrophil-depleted A. fumigatus-infected mice allowed specific localization of lung infection when combined with PET. Optical imaging with a fluorochrome-labeled version of the mAb showed colocalization with invasive hyphae. The mAb-based newly developed PET tracer [64Cu]DOTA-JF5 distinguished IPA from bacterial lung infections and, in contrast to [18F]FDG-PET, discriminated IPA from a general increase in metabolic activity associated with lung inflammation. To our knowledge, this is the first time that antibody-guided in vivo imaging has been used for noninvasive diagnosis of a fungal lung disease (IPA) of humans, an approach with enormous potential for diagnosis of infectious diseases and with potential for clinical translation. PMID:26787852

  11. Application of an anti-HQIgY antibody for the measurement of IgY concentrations of hen's and quail's serum and yolk.

    PubMed

    Losonczy, S; Szabó, C; Kiss, Z; Bárdos, L

    1999-01-01

    The development of a sensitive ELISA for the measurement of quail IgY (QIgY) was the main purpose of our study. The suitable antibody (AB) was prepared in rabbits. Both quail IgY (QIgY) and hen IgY (HIgY) were precipitated by this developed AB. For this reason it was marked as anti-hen-quail-IgY (a-HQIgY). The purified AB was conjugated with horseradish peroxidase (aHQIgY-HRP) and a sensitive direct ELISA was developed, based on this labeled AB. The prepared aHQIgY AB which was used in this developed ELISA method was suitable for the measurement of total and specific IgY concentration in domestic hen (Gallus domesticus) and Japanese quail (Coturnix coturnix japonica) either. As a result of our experiments it is very likely that there are identical sequences of IgYs of both species. This part of IgY has good antigen character at the same time. Probably, this phenomenon has occurrence in other Galliform species, too. Further investigations will be carried out in this field.

  12. Immunochemical Parameters of Some Commercial Conjugates for the Fluorescent Treponemal Antibody-Absorption Test

    PubMed Central

    Hunter, E. F.; Smith, J. F.; Lewis, J. S.; McGrew, B. E.; Schmale, J. D.

    1972-01-01

    Fluorescein-labeled anti-human globulins were examined to determine the need for standardization of conjugates used in the fluorescent treponemal antibody-absorption (FTA-ABS) test. Twenty-one of 33 conjugates submitted by commercial manufacturers to the Reagents Control Activity, Venereal Disease Research Laboratory, for evaluation in the FTA-ABS test were available for study. Conjugates, after evaluation in FTA-ABS performance tests, were examined by immunoelectrophoresis, by titration against immunoglobulins G and M (IgG, IgM) with FTA-ABS techniques, and by the biuret protein and fluorescein diacetate methods for determining fluorescein to protein (F/P) ratios. The conjugates were predominately anti-IgG globulin with anti-light-chain activity. Differences were noted in the ability of some conjugates to detect IgM antibody. The F/P ratios of those conjugates that could be determined varied from 2.6 to 17.8 μg of fluorescein per mg of protein. The need to identify and standardize both the immunologic capabilities and the optimum F/P ratio for FTA-ABS test conjugates is presented. PMID:4564403

  13. Selective biotinylation of Neisseria meningitidis group B capsular polysaccharide and application in an improved ELISA for the detection of specific antibodies.

    PubMed

    Diaz Romero, J; Outschoorn, I

    1993-03-15

    A method is described for the selective biotinylation of meningococcal capsular polysaccharide from Neisseria meningitidis group B and its application to an enzyme-linked immunoabsorbent assay (ELISA) to detect specific antibodies by immobilization on streptavidin-coated microtiter wells. Capsular polysaccharide from Neisseria meningitidis B has been biotinylated by specific periodate oxidation of terminal residues and condensation of the resulting aldehydes with biotin hydrazide, using a spin-column technique in the intermediate purification steps. The ELISA was optimized employing an extended reaction time between the label alkaline phosphatase and its most common substrate, p-nitrophenyl phosphate, together with evaluation of blocking agents to minimize non-specific binding. Specificity was demonstrated by a direct competitive enzyme immunoassay (EIA).

  14. International energy outlook, 2000

    DOT National Transportation Integrated Search

    2000-03-01

    The International Energy Outlook 2000 (IEO2000) presents : an assessment by the Energy Information Administration : (EIA) of the outlook for international energy : markets through 2020. The report is an extension of the : EIAs Annual Energy Outloo...

  15. Magnetospheric disturbance effects on the Equatorial Ionization Anomaly (EIA) : an overview

    NASA Astrophysics Data System (ADS)

    Abdu, M. A.; Sobral, J. H. A.; de Paula, E. R.; Batista, I. S.

    1992-12-01

    The Equatorial lonization Anomaly (EIA) development can undergo drastic modification in the form of an anomalous occurrence at local times outside that of its quiet time development and/or inhibition/enhancement at local times of its normal occurrences. This happens for disturbed electrodynamic conditions of the global ionosphere-thermosphere-magnetosphere system, consequent upon the triggering of a magnetospheric storm event. Direct penetration to equatorial latitudes of the magnetospheric electric fields and the thermospheric disturbances involving winds, electric fields and composition changes produce significant alteration in the EIA morphology and dynamics. Results on statistical behaviour based on accumulated ground-based data sets, and those from recent theoretical modelling efforts and from satellite and ground-based observations, are reviewed. Some outstanding problems of the EIA response to magnetospheric disturbances that deserve attention in the coming years are pointed out.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marara, Madeleine; Okello, Nick; Kuhanwa, Zainab

    This paper reviews and compares the condition of the environmental impact assessment (EIA) system in three countries in the East Africa region: Kenya, Rwanda and Tanzania. The criteria used for the evaluation and the comparison of each system are based on the elements of the legal, administrative and procedural frameworks, as well as the context in which they operate. These criteria are adapted from the evaluation and quality control criteria derived from a number of literature sources. The study reveals that the EIA systems of Kenya and Tanzania are at a similar stage in their development. The two countries, themore » first to introduce the EIA concept into their jurisdiction in this part of Africa, therefore have more experience than Rwanda in the practice of environmental impact assessment, where the legislation and process requires more time to mature both from the governmental and societal perspective. The analysis of the administrative and procedural frameworks highlights the weakness in the autonomy of the competent authority, in all three countries. Finally a major finding of this study is that the contextual set up i.e. the socio-economic and political situation plays an important role in the performance of an EIA system. The context in developing countries is very different from developed countries where the EIA concept originates. Interpreting EIA conditions in countries like Kenya, Rwanda and Tanzania requires that the analysis for determining the effectiveness of their systems should be undertaken within a relevant framework, taking into account the specific requirements of those countries.« less

  17. Assessment of transboundary environmental effects in the Pearl River Delta Region: Is there a role for strategic environmental assessment?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marsden, Simon, E-mail: simon.marsden@flinders.edu.au

    2011-11-15

    China's EIA Law does not require transboundary proposals to be assessed, despite recognition of this globally, for example in the Espoo Convention and Kiev Protocol, and in the European EIA and SEA Directives. In a transboundary context assessment within a state is unusual, as regulating these effects is primarily about the relationship between states. However where a state has more than one legal system such as in the Pearl River Delta (PRD) Region of southern China, transboundary effects should also be addressed. Yet despite the geographical connections between Guangdong Province in mainland China (where the EIA Law applies) and themore » Hong Kong and Macau Special Administrative Regions (which have their own provisions, neither of which requires transboundary assessments), EIA and SEA are carried out separately. Coordinated or joint approaches to transboundary assessment are generally absent, with the legal autonomy of Hong Kong and Macau a major constraint. As a result institutional responses at the policy level have developed. The article considers global experiences with regulating transboundary EIA and SEA, and analyses potential application to land use, transport and air and water planning in the PRD Region. If applied, benefits may include prevention or mitigation of cumulative effects, broader public participation, and improvements to environmental governance. The PRD Region experience may encourage China to conduct and coordinate EIA and SEA processes with neighbouring states, which has been non-existent or extremely limited to date.« less

  18. A highly specific competitive direct enzyme immunoassay for sterigmatocystin as a tool for rapid immunochemotaxonomic differentiation of mycotoxigenic Aspergillus species.

    PubMed

    Wegner, S; Bauer, J I; Dietrich, R; Märtlbauer, E; Usleber, E; Gottschalk, C; Gross, M

    2017-02-01

    A simplified method to produce specific polyclonal rabbit antibodies against sterigmatocystin (STC) was established, using a STC-glycolic acid-ether derivative (STC-GE) conjugated to keyhole limpet haemocyanin (immunogen). The competitive direct enzyme immunoassay (EIA) established for STC had a detection limit (20% binding inhibition) of 130 pg ml -1 . The test was highly specific for STC, with minor cross-reactivity with O-methylsterigmatocystin (OMSTC, 0·87%) and negligible reactivity with aflatoxins (<0·02%). STC-EIA was used in combination with a previously developed specific EIA for aflatoxins (<0·1% cross-reactivity with STC and OMSTC), to study the STC/aflatoxin production profiles of reference strains of Aspergillus species. This immunochemotaxonomic procedure was found to be a convenient tool to identify STC- or aflatoxin-producing strains. The carcinogenic mycotoxin sterigmatocystin (STC) is produced by several Aspergillus species, either alone or together with aflatoxins. Here, we report a very simple and straightforward procedure to obtain highly sensitive and specific anti-STC antibodies, and their use in the first ever real STC-specific competitive direct enzyme immunoassay (EIA). In combination with a previous EIA for aflatoxins, this study for the first time demonstrates the potential of a STC/aflatoxin EIA pair for what is branded as 'immunochemotaxonomic' identification of mycotoxigenic Aspergillus species. This new analytical tool enhances analytical possibilities for differential analysis of STC and aflatoxins. © 2016 The Society for Applied Microbiology.

  19. Spatio-temporal characteristics of the Equatorial Ionization Anomaly (EIA) in the East African region via ionospheric tomography during the year 2012

    NASA Astrophysics Data System (ADS)

    Kassa, T.; Damtie, B.; Bires, A.; Yizengaw, E.; Cilliers, P.

    2015-01-01

    We present the characteristics of the EIA in the East African sector inferred from ground-based GPS receivers via ionospheric tomography during the year 2012. For the analysis, we developed and used a 2D ionospheric tomography imaging software based on Bayesian inversion approach. To reconstruct ionospheric electron density form slant Total Electron Content (sTEC) measurements, we selected a chain of ten ground-based GPS receivers with stations' codes and geomagnetic coordinates: ARMI (3.03 °S, 109.29 °E), DEBK (4.32 °N, 109.48 °E), ASOS (1.14 °N, 106.16 °E), NEGE (3.60 °S, 111.35 °E), SHIS (3.26 °N, 110.62 °E), ASAB (4.91 °N, 114.34 °E), SHEB (7.36 °N, 110.60 °E), EBBE (9.54 °S, 104.10 °E), DODM (16.03 °S, 109.04 °E) & NAMA (11.49 °N, 113.60 °E). The temporal, spatial and storm-time characteristics of the EIA and the hourly, day-to-day and seasonal variations of the maximum electron density of F2 region (NmF2) at 15.29°S geomagnetic latitude are presented. We found that the magnitude of the peak and the width/thickness of the EIA pronounced during the equinox and weakened during the solstice seasons at 2100 LT. It is also observed that the EIA persisted for longer time in equinox season than the solstice season. The spatial appearance of the northern and southern anomalies are observed starting from 6.12 ° N and 10 ° S respectively along geomagnetic latitude during equinox season. The EIA is localized between 180 km and 450 km along the altitude during December solstice. The analysis on the NmF2 demonstrated a significant dependence on local time, day and season of the year. We also investigated the storm response of the EIA for the magnetic storm of Day Of the Year (DOY) 274-276. It is observed that the disturbance dynamo related composition change (O/N2 ratio) resulted in a well-developed EIA with an increase in the peak and the width of the EIA at 2100 LT on DOY 275 (main phase of the storm) compared to 274 (initial phase of the storm) and 276 (recovery phase of the storm).

  20. Assessing the influence of Environmental Impact Assessments on science and policy: an analysis of the Three Gorges Project.

    PubMed

    Tullos, Desiree

    2009-07-01

    The need to understand and minimize negative environmental outcomes associated with large dams has both contributed to and benefited from the introduction and subsequent improvements in the Environmental Impact Assessment (EIA) process. However, several limitations in the EIA process remain, including those associated with the uncertainty and significance of impact projections. These limitations are directly related to the feedback between science and policy, with information gaps in scientific understanding discovered through the EIA process contributing valuable recommendations on critical focus areas for prioritizing and funding research within the fields of ecological conservation and river engineering. This paper presents an analysis of the EIA process for the Three Gorges Project (TGP) in China as a case study for evaluating this feedback between the EIA and science and policy. For one of the best-studied public development projects in the world, this paper presents an investigation into whether patterns exist between the scientific interest (via number of publications) in environmental impacts and (a) the identification of impacts as uncertain or priority by the EIA, (b) decisions or political events associated with the dam, and (c) impact type. This analysis includes the compilation of literature on TGP, characterization of ecosystem interactions and responses to TGP through a hierarchy of impacts, coding of EIA impacts as "uncertain" impacts that require additional study and "priority" impacts that have particularly high significance, mapping of an event chronology to relate policies, institutional changes, and decisions about TGP as "events" that could influence the focus and intensity of scientific investigation, and analysis of the number of publications by impact type and order within the impact hierarchy. From these analyses, it appears that the availability and consistency of scientific information limit the accuracy of environmental impact projections. These analyses also suggest a lack of direct feedback between the EIA process and emerging science, as indicated by the failure of literature to focus on issues related to the design and management of TGP, ultimately challenging the environmental sustainability of the project. While the EIA process has enormous potential for improving both the basic sciences and the planning and sustainability of hydrodevelopment, important institutional changes need to occur for this potential to be realized. This paper concludes with recommendations about those institutional changes needed to improve the feedback between the science and policy, and ultimately the environmental sustainability, of large dams.

  1. Establishing reliable production of the PET isotope 89Zr for research use: From target fabrication to preclinical imaging

    NASA Astrophysics Data System (ADS)

    Scharli, R. K.; Price, R. I.; Chan, S.; Cryer, D.; Jeffery, C. M.; Asad, A. H.; Morandeau, L.; Eu, P.; Cullinane, C.; Kasbollah, A.; Katsifis, A.

    2012-12-01

    A semi-automated, in-house external beamline, ≤40 μA at 11.7 MeV for 120 min (degraded from 18 MeV to suppress 88Y & 88Zr co-production) produced 89Zr from 89Y(p,n)89Zr. EOB activity (by HPGe γ-spectr.) of 89Zr in target discs, derived from multiple runs, was 1.42 GBq (±0.45 GBq [SD], n=4) which was 67% (±21%, n=4) of the theoretical activity, with a maximum of 1.84 GBq (87% of theory) achieved. Recovery was 88% (±9%, n=4), radionuclidic purity >99% (n=4) and chemical purity 0.2 ppm Zr (±0.3 ppm, n=3, ICP-MS). The Zr:Y ratio improved from 1:10000 in the pre-filtered solution to 1:10 in the product purified by hydroxamate column. Efficiency of radiolabeling to monoclonal antibody (mAb; trastuzumab) was 100% and purified 89Zr did not bind non-specifically to mAb. Chelator:mAb ratio was 1.3:1. No-carrier-added specific activity of purified 89Zr was 408 MBq/μg (±26 MBq/μg, n=2) via the titration-by-chelator method. Minimum ligand concentration for which 100% labeling occurred was 302 nmol/L. Small animal PET imaging (Philips Mosaic; scan acquisition time 10 min; decay & randoms corrected; image reconstructed using a 3-D RAMLA algorithm) demonstrated marked tumor-specific uptake of 89Zr-labeled mAb but nil 'free' 89Zr (as chloride) tumor uptake.

  2. Facile quantitation of free thiols in a recombinant monoclonal antibody by reversed-phase high performance liquid chromatography with hydrophobicity-tailored thiol derivatization.

    PubMed

    Welch, Leslie; Dong, Xiao; Hewitt, Daniel; Irwin, Michelle; McCarty, Luke; Tsai, Christina; Baginski, Tomasz

    2018-06-02

    Free thiol content, and its consistency, is one of the product quality attributes of interest during technical development of manufactured recombinant monoclonal antibodies (mAbs). We describe a new, mid/high-throughput reversed-phase-high performance liquid chromatography (RP-HPLC) method coupled with derivatization of free thiols, for the determination of total free thiol content in an E. coli-expressed therapeutic monovalent monoclonal antibody mAb1. Initial selection of the derivatization reagent used an hydrophobicity-tailored approach. Maleimide-based thiol-reactive reagents with varying degrees of hydrophobicity were assessed to identify and select one that provided adequate chromatographic resolution and robust quantitation of free thiol-containing mAb1 forms. The method relies on covalent derivatization of free thiols in denatured mAb1 with N-tert-butylmaleimide (NtBM) label, followed by RP-HPLC separation with UV-based quantitation of native (disulfide containing) and labeled (free thiol containing) forms. The method demonstrated good specificity, precision, linearity, accuracy and robustness. Accuracy of the method, for samples with a wide range of free thiol content, was demonstrated using admixtures as well as by comparison to an orthogonal LC-MS peptide mapping method with isotope tagging of free thiols. The developed method has a facile workflow which fits well into both R&D characterization and quality control (QC) testing environments. The hydrophobicity-tailored approach to the selection of free thiol derivatization reagent is easily applied to the rapid development of free thiol quantitation methods for full-length recombinant antibodies. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. Enhancement of tumor-to-nontumor localization ratios by hepatocyte-directed blood clearance of antibodies labeled with certain residualizing radiolabels.

    PubMed

    Patel, S; Stein, R; Ong, G L; Goldenberg, D M; Mattes, M J

    1999-08-01

    To increase tumor-to-nontumor localization ratios of injected radiolabeled antibodies (Abs), several interrelated methods were used. The model systems used were two human carcinoma xenografts grown in nude mice, targeted by antibodies RS11 (antiepithelial glycoprotein-2) or MN-14 (anticarcinoembryonic antigen). The Abs were conjugated with biotin and 111In-benzyl diethylenetriamine pentaacetic acid, and, at various times after injection, were cleared by intraperitoneal injection of galactosylated streptavidin, which delivers the complexes to hepatocytes. The radiolabel used was selected because it is retained within tumors after catabolism of the Ab by the tumor cell but is quite rapidly excreted from hepatocytes into bile. With blood clearance induced at 24 h, and dissection 5 h later, high tumor-to-nontumor ratios were attained. Depending on the model used, tumor-to-blood ratios were 16:1 to 31:1, and tumor-to-nontumor ratios for the kidney, lungs and bone were also high and greatly increased by the clearance regimen. Despite clearance into the liver, tumor-to-liver ratios remained >1, due to fairly rapid biliary excretion of the label. The absolute antibody uptake by the tumors was also high, because 24 h was allowed for the Ab to penetrate and bind to cells within the subcutaneous tumors. The method described produced high tumor-to-nontumor ratios at 1 d after injection and may be advantageous for tumor imaging with antibodies. Radiation dosimetry calculations indicate that there is only a slight advantage with this approach for radioimmunotherapy.

  4. Comparison between DOT EIA IgM and Widal Test as early diagnosis of typhoid fever.

    PubMed

    Begum, Z; Hossain, M A; Musa, A K; Shamsuzzaman, A K; Mahmud, M C; Ahsan, M M; Sumona, A A; Ahmed, S; Jahan, N A; Alam, M; Begum, A

    2009-01-01

    A recently developed DOT enzyme immunoassay known as "Typhidot" for detecting IgM antibody against 50 KDa OMP antigen of Salmonella typhi, was evaluated on 100 clinically suspected typhoid fever cases and 40 age-sex matched controls, in the Department of Microbiology, Mymensingh Medical College during, the period from June 2006 to July 2007. Blood culture, Widal test, and DOT EIA for IgM test were performed in all patients. Among 100 clinically suspected typhoid fever cases, 35 were subsequently confirmed on the basis of positive blood culture for S. typhi and/or significant rising titre of Widal test. The DOT EIA IgM test could produce results within 1 hour. The result of the DOT EIA IgM test showed a good diagnostic value for typhoid fever. The sensitivity, specificity, positive and negative predictive value of the test was found as 91.42%, 90.00%, 88.88% and 92.30% respectively. On the other hand corresponding values for Widal test were of 42.85%, 85.00%, 71.42% and 62.96% respectively. Thus, The DOT EIA IgM seems to be a practical alternative to Widal test for early diagnosis of typhoid fever.

  5. EIA screening and nature protection in Denmark.

    PubMed

    Christensen, Per; Kørnøv, Lone

    2011-04-01

    The number of environmental impact assessment (EIA) screenings in Denmark has increased dramatically since 2000. This is a consequence of increased pig production as well as the concentration of production on larger farms. In the same period, EIA rules have developed primarily due to an increased focus on the protection of groundwater and Natura 2000 sites. In particular, the implementation of Natura 2000 in Danish legislation has increased the demands on many farms. In its rulings on appealed cases, the Nature Protection Board of Appeal has strengthened its demands, and this is mirrored in screening practices. In this paper, the demands formulated in the guidelines of local authorities were analysed in order to investigate how the protection of groundwater, coastal waters, lakes and Natura 2000 sites develops through EIA screening. It is concluded that the level of protection has improved, and that the main cause for this is not EIA regulations as such, but the positive role which the implementation of the Natura 2000 objectives has played in this development. However, it was also found that the formulation of demands varies greatly between the counties, thus often resulting in ambiguity and leaving room for quite different practices in different counties. Copyright © 2010 Elsevier Ltd. All rights reserved.

  6. Identification of a factor in HeLa cells specific for an upstream transcriptional control sequence of an EIA-inducible adenovirus promoter and its relative abundance in infected and uninfected cells.

    PubMed Central

    SivaRaman, L; Subramanian, S; Thimmappaya, B

    1986-01-01

    Utilizing the gel electrophoresis/DNA binding assay, a factor specific for the upstream transcriptional control sequence of the EIA-inducible adenovirus EIIA-early promoter has been detected in HeLa cell nuclear extract. Analysis of linker-scanning mutants of the promoter by DNA binding assays and methylation-interference experiments show that the factor binds to the 17-nucleotide sequence 5' TGGAGATGACGTAGTTT 3' located between positions -66 and -82 upstream from the cap site. This sequence has been shown to be essential for transcription of this promoter. The EIIA-early-promoter specific factor was found to be present at comparable levels in uninfected HeLa cells and in cells infected with either wild-type adenovirus or the EIA-deletion mutant dl312 under conditions in which the EIA proteins are induced to high levels [7 or 20 hr after infection in the presence of arabinonucleoside (cytosine arabinoside)]. Based on the quantitation in DNA binding assays, it appears that the mechanism of EIA-activated transcription of the EIIA-early promoter does not involve a net change in the amounts of this factor. Images PMID:2942943

  7. Lunar Tidal Modulation of Periodic Meridional Movement of Equatorial Ionization Anomaly Crest During Sudden Stratospheric Warming

    NASA Astrophysics Data System (ADS)

    Mo, X. H.; Zhang, D. H.

    2018-02-01

    Using the location of equatorial ionization anomaly (EIA) crest derived from GPS observations in China and Brazilian sector, we investigated the longitudinal dependence of periodic meridional movement of EIA crest during sudden stratospheric warming events in 2003, 2006, and 2009. The solar activity was from high to low for the three events. Results show that the locations of EIA crests in both China and Brazilian sectors exhibit obvious and constant 14- to 15-day periodic oscillation being in-phase in two sectors, which coincide with the half of the lunar revolution period (29.53 days) and the lunar phase. The temporal extent of wave power at 14-15 days is consistent with the temporal extent of stratospheric zonal wind, indicating that 14- to 15-day periodic meridional movement of EIA crest is due to enhanced lunar tide modulated by zonal wind. In addition, it is also found that the amplitude of 14- to 15-day periodic oscillation of EIA crest in China sector is larger than that in Brazilian sector, which may be caused by the longitudinal variation of tides and neutral wind pattern.

  8. Ecological impact assessments fail to reduce risk of bat casualties at wind farms.

    PubMed

    Lintott, Paul R; Richardson, Suzanne M; Hosken, David J; Fensome, Sophie A; Mathews, Fiona

    2016-11-07

    Demand for renewable energy is rising exponentially. While this has benefits in reducing greenhouse gas emissions, there may be costs to biodiversity [1]. Environmental Impact Assessments (EIAs) are the main tool used across the world to predict the overall positive and negative effects of renewable energy developments before planning consent is given, and the Ecological Impact Assessments (EcIAs) within them assess their species-specific effects. Given that EIAs are undertaken globally, are extremely expensive, and are enshrined in legislation, their place in evidence-based decision making deserves evaluation. Here we assess how well EIAs of wind-farm developments protect bats. We found they do not predict the risks to bats accurately, and even in those cases where high risk was correctly identified, the mitigation deployed did not avert the risk. Given that the primary purpose of an EIA is to make planning decisions evidence-based, our results indicate that EIA mitigation strategies used to date have been ineffective in protecting bats. In the future, greater emphasis should be placed on assessing the actual impacts post-construction and on developing effective mitigation strategies. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  9. Nonmigrating tidal modulation of the equatorial thermosphere and ionosphere anomaly

    NASA Astrophysics Data System (ADS)

    Lei, Jiuhou; Thayer, Jeffrey P.; Wang, Wenbin; Yue, Jia; Dou, Xiankang

    2014-04-01

    The modulation of nonmigrating tides on both the ionospheric equatorial ionization anomaly (EIA) and the equatorial thermosphere anomaly (ETA) is investigated on the basis of simulations from the Thermosphere Ionosphere Mesosphere Electrodynamics General Circulation Model (TIME-GCM). Our simulations demonstrate the distinct features of the EIA and ETA seen in observations after the inclusion of field-aligned ion drag in the model. Both the EIA and the ETA in the constant local time frame display an obvious zonal wave-4 structure associated with the modulation of nonmigrating tides. However, the modeled EIA and ETA show a primary zonal wave-1 structure when only the migrating tides are specified at the model lower boundary. Our simulations reveal that the zonal wave-4 structure of the ETA under both low and high solar activity conditions is mainly caused by the direct response of the upper thermosphere to the diurnal eastward wave number 3 and semidiurnal eastward wave number 2 nonmigrating tides from the lower atmosphere. There is a minor contribution from the ion-neutral coupling. The zonal wave-4 structure of the EIA is also caused by these nonmigrating tides but through the modulation of the neutral wind dynamo.

  10. Sequencing of chondroitin sulfate oligosaccharides using a novel exolyase from a marine bacterium that degrades hyaluronan and chondroitin sulfate/dermatan sulfate.

    PubMed

    Wang, Wenshuang; Cai, Xiaojuan; Han, Naihan; Han, Wenjun; Sugahara, Kazuyuki; Li, Fuchuan

    2017-11-09

    Glycosaminoglycans (GAGs) are a family of chemically heterogeneous polysaccharides that play important roles in physiological and pathological processes. Owing to the structural complexity of GAGs, their sophisticated chemical structures and biological functions have not been extensively studied. Lyases that cleave GAGs are important tools for structural analysis. Although various GAG lyases have been identified, exolytic lyases with unique enzymatic property are urgently needed for GAG sequencing. In the present study, a putative exolytic GAG lyase from a marine bacterium was recombinantly expressed and characterized in detail. Since it showed exolytic lyase activity toward hyaluronan (HA), chondroitin sulfate (CS), and dermatan sulfate (DS), it was designated as HCDLase. This novel exolyase exhibited the highest activity in Tris-HCl buffer (pH 7.0) at 30°C. Especially, it showed a specific activity that released 2-aminobenzamide (2-AB)-labeled disaccharides from the reducing end of 2-AB-labeled CS oligosaccharides, which suggest that HCDLase is not only a novel exolytic lyase that can split disaccharide residues from the reducing termini of sugar chains but also a useful tool for the sequencing of CS chains. Notably, HCDLase could not digest 2-AB-labeled oligosaccharides from HA, DS, or unsulfated chondroitin, which indicated that sulfates and bond types affect the catalytic activity of HCDLase. Finally, this enzyme combined with CSase ABC was successfully applied for the sequencing of several CS hexa- and octasaccharides with complex structures. The identification of HCDLase provides a useful tool for CS-related research and applications. © 2017 The Author(s). Published by Portland Press Limited on behalf of the Biochemical Society.

  11. Flexible Label-Free Quantitative Assay for Antibodies to Influenza Virus Hemagglutinins ▿

    PubMed Central

    Carney, Paul J.; Lipatov, Aleksandr S.; Monto, Arnold S.; Donis, Ruben O.; Stevens, James

    2010-01-01

    During the initial pandemic influenza H1N1 virus outbreak, assays such as hemagglutination inhibition and microneutralization provided important information on the relative protection afforded by the population's cross-reactivity from prior infections and immunizations with seasonal vaccines. However, these assays continue to be limited in that they are difficult to automate for high throughput, such as in pandemic situations, as well as to standardize between labs. Thus, new technologies are being sought to improve standardization, reliability, and throughput by using chemically defined reagents rather than whole cells and virions. We now report the use of a cell-free and label-free flu antibody biosensor assay (f-AbBA) for influenza research and diagnostics that utilizes recombinant hemagglutinin (HA) in conjunction with label-free biolayer interferometry technology to measure biomolecular interactions between the HA and specific anti-HA antibodies or sialylated ligands. We evaluated f-AbBA to determine anti-HA antibody binding activity in serum or plasma to assess vaccine-induced humoral responses. This assay can reveal the impact of antigenic difference on antibody binding to HA and also measure binding to different subtypes of HA. We also show that the biosensor assay can measure the ability of HA to bind a model sialylated receptor-like ligand. f-AbBA could be used in global surveillance laboratories since preliminary tests on desiccated HA probes showed no loss of activity after >2 months in storage at room temperature, indicating that the same reagent lots could be used in different laboratories to minimize interlaboratory assay fluctuation. Future development of such reagents and similar technologies may offer a robust platform for future influenza surveillance activities. PMID:20660137

  12. Autoantibodies to human tryptophan hydroxylase and aromatic L-amino acid decarboxylase.

    PubMed

    Dal Pra, Chiara; Chen, Shu; Betterle, Corrado; Zanchetta, Renato; McGrath, Vivienne; Furmaniak, Jadwiga; Rees Smith, Bernard

    2004-03-01

    To assess the prevalence of autoantibodies (Abs) to tryptophan hydroxylase (TPH) and aromatic l-amino acid decarboxylase (AADC) in patients with different autoimmune diseases and to analyse their respective epitopes. TPH and AADC Abs were measured in an immunoprecipitation assay using (35)S-labelled full-length and fragments of TPH and AADC. Patients with different autoimmune adrenal diseases (n=84), non-adrenal autoimmune diseases (n=37), idiopathic vitiligo (n=8) and 56 healthy blood donors were studied. Fourteen of twenty-three (61%) of patients with autoimmune polyglandular syndrome (APS) type I and 1/34 (3%) of patients with isolated Addison's disease (AD) were positive for TPH Abs. None of the patients with APS type II (n=27), coeliac disease (n=10), autoimmune thyroid disease (AITD) (n=11), type 1 diabetes mellitus (DM) (n=16) or idiopathic vitiligo (n=8) was positive for TPH Abs. AADC Abs were detected in 12/23 (52%) patients with APS type I, in 1/29 (3%) patients with APS type II and 1/34 (3%) patients with isolated AD. None of the patients with coeliac disease, type 1 DM, AITD or idiopathic vitiligo was positive for AADC Abs. TPH Abs were found to interact with the C-terminal amino acids (aa) 308-423, central aa 164-205 and N-terminal aa 1-105 of the TPH molecule. AADC Ab binding epitopes were within the C-terminal aa 382-483, the central aa 243-381 and the N-terminal aa 1-167. Our study suggests that TPH Abs and AADC Abs react with several different epitopes and that different epitopes are recognized by different sera. The prevalence of TPH Abs and AADC Abs in patients with APS type I in our study is in agreement with previous reports. TPH Abs and AADC Abs were found very rarely in patients with other forms of autoimmune adrenal disease and were not detected in patients with non-adrenal autoimmune diseases.

  13. A Rapid Dot Immunoassay for the Detection of Serum Antibodies to Eastern Equine Encephalomyelitis and Saint Louis Encephalitis Viruses in Sentinel Chickens

    DTIC Science & Technology

    1988-01-01

    tion inhibition (HI) tests .6 uses a novel membrane, polyvinylydine difluor- EEE and SLE viruses are significant public ide (PVDF), and yields a...only 3 aged values between the two tests (Fig. 3). Vari- of 6 SLE virus-inoculated birds developed an- ability in EIA titer was observed with samples... SLE samples negative by EIA were location. Four serum samples from each of 3 also negative by DotIA. EEE-positive chickens were tested by EIA and A

  14. Two distinct cellular proteins interact with the EIa-responsive element of an adenovirus early promoter.

    PubMed Central

    Jansen-Durr, P; Wintzerith, M; Reimund, B; Hauss, C; Kédinger, C

    1990-01-01

    EIa-dependent transactivation of the adenovirus EIIa early (EIIaE) promoter is correlated with the activation of the cellular transcription factor E2F. In this study we identified a cellular protein, C alpha, that is distinct from E2F and that binds two sites in the EIIaE promoter, one of which overlaps with the proximal E2F binding site of the EIIaE promoter. The possible involvement of C alpha in the EIa responsiveness of this promoter is discussed. Images PMID:2139142

  15. Plasma cortisol and 11-ketotestosterone enzyme immunoassay (EIA) kit validation for three fish species: the orange clownfish Amphiprion percula, the orangefin anemonefish Amphiprion chrysopterus and the blacktip reef shark Carcharhinus melanopterus.

    PubMed

    Mills, S C; Mourier, J; Galzin, R

    2010-08-01

    Commercially available enzyme immunoassay (EIA) kits were validated for measuring steroid hormone concentrations in blood plasma from three fish species: the orange clownfish Amphiprion percula, the orangefin anemonefish Amphiprion chrysopterus and the blacktip reef shark Carcharhinus melanopterus. A minimum of 5 microl plasma was required to estimate hormone concentrations with both kits. These EIA kits are a simple method requiring minimal equipment, for measuring hormone profiles under field conditions.

  16. Potential Oil Production from Coastal Plain of Arctic National Wildlife Refuge: Updated Assessment

    EIA Publications

    2000-01-01

    The Energy Information Administration (EIA) received a letter (dated March 10, 2000) from Senator Frank H. Murkowski as Chairman of the Senate Committee on Energy and Natural Resources requesting an EIA Service Report with plausible scenarios for the Arctic National Wildlife Refuge (ANWR) supply development consistent with the most recent U.S. Geological Survey resource assessments. This service report is prepared in response to the request of Senator Murkowski. It focuses on the ANWR coastal plain, a region currently restricted from exploration and development, and updates EIA's 1987 ANWR assessment.

  17. Notice of Changes to the Weekly Natural Gas Storage Report

    EIA Publications

    2015-01-01

    On November 19, 2015, EIA will release the Weekly Natural Gas Storage Report (WNGSR) with new data breakouts for five regions of the Lower 48 states, converting from the current three-region structure. On Monday, November 16, 2015, EIA will re-release the data that will be published on Friday, November 13 (for the week ending Friday, November 6) in the new five-region format. The release will be conducted through the same timed countdown procedures used for normal releases on the same WNGSR web page: http://ir.eia.gov/ngs/ngs.html.

  18. The Non-Impact of Scientific Reviews of Oil Sands Environmental Impact Assessments

    NASA Astrophysics Data System (ADS)

    Kienzle, S. W.; Byrne, J.

    2008-12-01

    Schindler (Science, Vol. 192: 509; 1976) stated that Environmental Impact Assessments authors "conduct the studies regardless of how quickly results are demanded, write large, diffuse reports containing reams of uninterpreted and incomplete descriptive data, and in some cases, construct "predictive" models, irrespective of the quality of the data base." Schindler offered a solution: "If we are to protect both our resources and scientific integrity, environmental scientists must seek to put their studies on a scientifically credible basis-to see that problems, terms of reference, funding, time constraints, reports, and conclusions are all within a bona fide scientific framework." When the first scientific panel was formed in 2003 by the Mikisew Cree First Nations (MCFN), Alberta, to objectively review EIAs of proposed oil sands mining projects, the scientific panel uncovered many severe omissions, errors, and a significant lack of substance that could not withstand scientific scrutiny. Neither the Terms of Reference for two major oilsands projects, estimated to be worth approximately CND 15 billion, nor the EIAs (one single EIA was over 11,000 pages long) contained the terms "climate change", "trend analysis", or "risk analysis", and nearly all environmental impacts were described by the proponents as "negligible". The Hydrology Section (over 950 pages in length) of one EIA did not contain a single peer-reviewed scientific publication. In summary, nothing had changed since Schindler's observations 27 years earlier. Since 2003, the authors have reviewed more than a dozen EIAs of proposed oilsands projects in northern Alberta. The "non-impact" of scientific reviews on the quality of EIAs and the insincerity of the stewards of the land are very sobering: apart from cosmetic improvements in the requirements of the Terms of Reference and the writing of the EIAs, no meaningful improvement of scientific content has been made. Key environmental concerns around water resource utilization and contamination, massive boreal forest ecosystem disruption and destruction, insignificant reclamation, and dramatic increases in emission of acidic pollutants and GHGs have never been adequately addressed. Spills of contaminated tailings fluids into the Athabasca River have occurred in the past, and Mikisew Cree Elders have both anecdotal and physical evidence of contamination of downstream areas through to Lake Athabasca. As the Alberta government has declared a sell-out of very large areas of boreal forest for fast profit, the scientific reviews have been ignored. With the exception of a few cosmetic improvements to the EIAs (e.g. climate change is now discussed, however, with incomplete data and incorrect interpretations), the scientific quality of EIAs has not improved. In fact, the Terms of Reference differ in content requirements with each oilsands project, which means that there is inconsistency between EIAs, prohibiting the evaluation of the evolution of the Terms of Reference. The consequences of the disregard of scientific standards are enormous environmental impacts in terms of carbon dioxide output, acid rain, severe health risks of the local population, water quality, and negligible reclamation efforts.

  19. Participatory environmental governance of infrastructure projects affecting reindeer husbandry in the Arctic.

    PubMed

    Landauer, Mia; Komendantova, Nadejda

    2018-06-22

    Several infrastructure projects are under development or already operational across the Arctic region. Often the deployment of such projects creates benefits at the national, regional, or global scales. However, local communities can experience negative impacts due to the requirements for extensive land areas, which cause pressure on traditional land use. Public participation in environmental planning such as Environmental Impact Assessment (EIA) enables local communities to provide feedback on the environmental, social, and economic challenges of infrastructure projects. Ideally, participation can improve the means of social learning for all involved parties and help to co-develop sustainable solutions. The subject of our research is reindeer herders' participation in EIA procedures of mines and wind farms in Finland because these types of projects affect reindeer husbandry. We study empirically how stakeholders involved in the EIAs perceive the participation of reindeer herders in the planning and implementation of infrastructure projects, and how these differ from the perceptions of the reindeer herders who are affected by the infrastructure projects. Our qualitative data is based on in-depth semi-structured interviews (N = 31) with members of the industry sector, consultants, governmental authorities, and representatives of local communities; in this study, the reindeer herders. The results show that herders' level of participation in the EIAs and the benefits and challenges of participation are perceived differently. Furthermore, the regulatory framework does not adequately ensure that the developer carries social and environmental responsibilities throughout the infrastructure project's lifetime, and that regular communication with herders will also be maintained after the EIAs. Herders' expertise should be used throughout the project lifetime. For example, more attention should be paid to both negotiating possible options for compensation and monitoring mechanisms when the infrastructure projects are pre-screened for the EIAs, as well as to co-designing the different project alternatives with herders for the EIAs. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. Virologic outcomes of HAART with concurrent use of cytochrome P450 enzyme-inducing antiepileptics: a retrospective case control study

    PubMed Central

    2011-01-01

    Background To evaluate the efficacy of highly-active antiretroviral therapy (HAART) in individuals taking cytochrome P450 enzyme-inducing antiepileptics (EI-EADs), we evaluated the virologic response to HAART with or without concurrent antiepileptic use. Methods Participants in the US Military HIV Natural History Study were included if taking HAART for ≥6 months with concurrent use of EI-AEDs phenytoin, carbamazepine, or phenobarbital for ≥28 days. Virologic outcomes were compared to HAART-treated participants taking AEDs that are not CYP450 enzyme-inducing (NEI-AED group) as well as to a matched group of individuals not taking AEDs (non-AED group). For participants with multiple HAART regimens with AED overlap, the first 3 overlaps were studied. Results EI-AED participants (n = 19) had greater virologic failure (62.5%) compared to NEI-AED participants (n = 85; 26.7%) for the first HAART/AED overlap period (OR 4.58 [1.47-14.25]; P = 0.009). Analysis of multiple overlap periods yielded consistent results (OR 4.29 [1.51-12.21]; P = 0.006). Virologic failure was also greater in the EI-AED versus NEI-AED group with multiple HAART/AED overlaps when adjusted for both year of and viral load at HAART initiation (OR 4.19 [1.54-11.44]; P = 0.005). Compared to the non-AED group (n = 190), EI-AED participants had greater virologic failure (62.5% vs. 42.5%; P = 0.134), however this result was only significant when adjusted for viral load at HAART initiation (OR 4.30 [1.02-18.07]; P = 0.046). Conclusions Consistent with data from pharmacokinetic studies demonstrating that EI-AED use may result in subtherapeutic levels of HAART, EI-AED use is associated with greater risk of virologic failure compared to NEI-AEDs when co-administered with HAART. Concurrent use of EI-AEDs and HAART should be avoided when possible. PMID:21575228

  1. Comparison of clinical performance of antigen based-enzyme immunoassay (EIA) and major outer membrane protein (MOMP)-PCR for detection of genital Chlamydia trachomatis infection

    PubMed Central

    Nateghi Rostami, Mahmoud; Hossein Rashidi, Batool; Aghsaghloo, Fatemeh; Nazari, Razieh

    2016-01-01

    Background: Chlamydia trachomatis is the most common sexually transmitted bacterial pathogen worldwide. Early detection and treatment of C.trachomatis genital infection prevent serious reproductive complications. Objective: Performances of enzyme immunoassay (EIA) and major outer membrane protein (MOMP)-polymerase chain reaction (PCR) for diagnosis of genital C.trachomatis infection in women were compared. Materials and Methods: In this cross sectional study a total of 518 women volunteers were included (33.67±8.3 yrs) who had been referred to Gynecology clinics of Qom province, Iran, were included. Endocervical swab specimens were collected to detect lipopolysaccharide (LPS) antigen in EIA and to amplify MOMP gene of C.trachomatis in PCR. Results were confirmed using ompI nested-PCR. Sensitivity, specificity, positive (PPV) and negative predictive values (NPV) were calculated for performance of the tests. Odds ratios were determined using binary logistic regression analysis. Results: In total, 37 (7.14%) cases were positive by EIA and/or MOMP-PCR. All discrepant results were confirmed by nested-PCR. Sensitivity, specificity, PPV and NPV values of EIA were 59.46%, 100%, 100% and 96.98%, and those of MOMP-PCR were 97.30%, 100%, 100%, 99.79%, respectively. Reproductive complications including 2.7% ectopic pregnancy, 5.4% stillbirth, 5.4% infertility, and 10.8% PROM were recorded. The risk of developing chlamydiosis was increased 4.8-fold in volunteers with cervicitis (p<0.05; OR 4.80; 95% CI 1.25-18.48). Conclusion: C.trachomatis infection should be regarded in women of reproductive ages especially those with cervicitis. Primary screening of women by using the low cost antigen-EIA is recommended; however, due to the low sensitivity of Ag-EIA, verification of the negative results by a DNA amplification method is needed. PMID:27525325

  2. Clostridium difficile Testing in the Clinical Laboratory by Use of Multiple Testing Algorithms ▿

    PubMed Central

    Novak-Weekley, Susan M.; Marlowe, Elizabeth M.; Miller, John M.; Cumpio, Joven; Nomura, Jim H.; Vance, Paula H.; Weissfeld, Alice

    2010-01-01

    The incidence of Clostridium difficile infection (CDI) has risen almost 3-fold in the United States over the past decade, emphasizing the need for rapid and accurate tests for CDI. The Cepheid Xpert C. difficile assay is an integrated, closed, nucleic acid amplification system that automates sample preparation and real-time PCR detection of the toxin B gene (tcdB). A total of 432 stool specimens from symptomatic patients were tested by a glutamate dehydrogenase (GDH) assay, a toxin A and B enzyme immunoassay (EIA), the Xpert C. difficile assay, and a cell culture cytotoxicity neutralization assay (CCCN). The results of these methods, used individually and in combination, were compared to those of toxigenic culture. Results for the Xpert C. difficile assay alone showed a sensitivity, specificity, positive predictive value, and negative predictive value (NPV) of 94.4, 96.3, 84.0, and 98.8%, while the EIA alone gave corresponding values of 58.3, 94.7, 68.9, and 91.9%, respectively. An algorithm using the GDH assay and the EIA (plus the CCCN if the EIA was negative) showed corresponding values of 83.1, 96.7, 83.1, and 96.1%. The Xpert C. difficile assay was statistically superior to the EIA (P, <0.001 by Fisher's exact test) and to the GDH-EIA-CCCN algorithm (P, 0.0363). Combining the GDH and Xpert C. difficile assays lowered both the sensitivity and the NPV of the Xpert assay. The GDH-EIA-CCCN procedure required, on average, 2 days to complete testing on GDH-positive results, while testing by the Xpert C. difficile assay was completed, on average, in less than 1 h. Xpert C. difficile testing yielded the highest sensitivity and NPV, in the least amount of time, of the individual- and multiple-test algorithms evaluated in this study. PMID:20071552

  3. β-(1,3)-Glucan Exposure Assessment by Passive Airborne Dust Sampling and New Sensitive Immunoassays▿

    PubMed Central

    Noss, Ilka; Wouters, Inge M.; Bezemer, Gillina; Metwali, Nervana; Sander, Ingrid; Raulf-Heimsoth, Monika; Heederik, Dick J. J.; Thorne, Peter S.; Doekes, Gert

    2010-01-01

    Associations between house dust-associated β-(1,3)-glucan exposure and airway inflammatory reactions have been reported, while such exposures in early childhood have been suggested to protect against asthma and wheezing. Most epidemiological studies have used reservoir dust samples and an inhibition enzyme immunoassay (EIA) for β-(1,3)-glucan exposure assessment. The objective of this study was to develop inexpensive but highly sensitive enzyme immunoassays to measure airborne β-(1,3)-glucans in low-exposure environments, like homes. Specificities of available anti-β-(1,3)-glucan antibodies were defined by direct and inhibition experiments. Three suitable antibody combinations were selected for sandwich EIAs. β-(1,3)-Glucans in passive airborne dust collected with an electrostatic dust fall collector (EDC) and floor dust from seven homes were measured with the three EIAs. Floor dust samples were additionally analyzed in the inhibition EIA. The sandwich EIAs were sensitive enough for airborne glucan measurement and showed different specificities for commercial glucans, while the β-(1,3)-glucan levels in house dust samples correlated strongly. The feasibility of measuring glucans in airborne dust with the recently introduced EDC method was further investigated by selecting the most suitable of the three EIAs to measure and compare β-(1,3)-glucan levels in the EDC and in floor and actively collected airborne dust samples of the previously performed EDC validation study. The EDC β-(1,3)-glucan levels correlated moderately with β-(1,3)-glucans in actively collected airborne dust and floor dust samples, while the glucan levels in the airborne dust and floor dust samples did not correlate. The combination of the newly developed β-(1,3)-glucan sandwich EIA with EDC sampling now allows assessment in large-scale population studies of exposure to airborne β-(1,3)-glucans in homes or other low-exposure environments. PMID:20038709

  4. Temporal evolution of the EIA along 95°E as obtained from GNSS TEC measurements and SAMI3 model

    NASA Astrophysics Data System (ADS)

    Kakoti, Geetashree; Kalita, Bitap Raj; Hazarika, Rumajyoti; Bhuyan, Pradip Kumar; Sharma, Sanjay; Tiwari, Ramesh Chandra

    2018-06-01

    The total electron content (TEC) derived from GNSS measurements at a trans-hemispheric meridional chain of ground stations around 95°E longitude are used to study the quiet time inter-hemispheric structure and dynamics of the equatorial ionization anomaly (EIA) during the period March 2015 to February 2016. The stations are Dibrugarh (27.5°N, 95°E, 43° dip), Kohima (25.6°N, 94.1°E, 39° dip), Aizawl (23.7°N, 92.8°E, 36° dip), Port Blair (11.63°N, 92.71°E, 9° dip) and Cocos Islands (12.2°S, 96.8°E, 43° dip). The observation shows that the northern crest of the EIA lies in the south of 23°N (Aizawl) in all seasons but recedes further south towards the equator during December solstice. The largest poleward expansion of the northern (southern) EIA is observed in the March equinox (December solstice). The equinoctial and hemispherical asymmetry of TEC is noted. The winter anomaly is observed in the northern hemisphere but not in the southern hemisphere. The highest midday TEC over any station is observed in the March equinox. The TEC in southern summer (December solstice) is significantly higher than that in the northern summer (June solstice). The observed northern EIA contracts equatorward in the postsunset period of solstice but the southern EIA persists late into the midnight in the December solstice. The asymmetry may be attributed to the different geographic location of the magnetically conjugate stations. The SAMI3 simulations broadly capture the EIA structure and the inter-hemispheric asymmetry during solstices. The difference between observations and the SAMI3 is higher in March equinox and December solstice. The higher E × B vertical drift in the 90-100°E sector and the large geographic-geomagnetic offset in observing stations may have contributed to the observed differences.

  5. Ab initio modeling of CW-ESR spectra of the double spin labeled peptide Fmoc-(Aib-Aib-TOAC)2-Aib-OMe in acetonitrile.

    PubMed

    Zerbetto, Mirco; Carlotto, Silvia; Polimeno, Antonino; Corvaja, Carlo; Franco, Lorenzo; Toniolo, Claudio; Formaggio, Fernando; Barone, Vincenzo; Cimino, Paola

    2007-03-15

    In this work we address the interpretation, via an ab initio integrated computational approach, of the CW-ESR spectra of the double spin labeled, 310-helical, peptide Fmoc-(Aib-Aib-TOAC)2-Aib-OMe dissolved in acetonitrile. Our approach is based on the determination of geometric and local magnetic parameters of the heptapeptide by quantum mechanical density functional calculations taking into account solvent and, when needed, vibrational averaging contributions. The system is then described by a stochastic Liouville equation for the two electron spins interacting with each other and with two 14N nuclear spins, in the presence of diffusive rotational dynamics. Parametrization of the diffusion rotational tensor is provided by a hydrodynamic model. CW-ESR spectra are simulated with minimal resorting to fitting procedures, proving that the combination of sensitive ESR spectroscopy and sophisticated modeling can be highly helpful in providing 3D structural and dynamic information on molecular systems.

  6. Effect of myasthenic patient sera on the number and distribution of acetylcholine receptors in muscle and nerve-muscle cultures from rat. Correlations with clinical state.

    PubMed

    Eymard, B; de la Porte, S; Pannier, C; Berrih-Aknin, S; Morel, E; Fardeau, M; Bach, J F; Koenig, J

    1988-08-01

    We studied the functional activities (FA) of sera obtained from 83 myasthenic patients on rat muscle cultures. Using the same sets of cultures, two parameters were evaluated after exposure to sera: residual fraction (RF) of acetylcholine receptors (AChR) coupled to 125I-labelled alpha-bungarotoxin (alpha Bgt) (81 sera) and the number of rhodamine labelled clusters (56 sera). Two types of culture were assayed: muscle alone and nerve-muscle cocultures (12 cases). In all combinations (fluorescence, radiolabelling, muscle alone and nerve-muscle cocultures), we found a significant correlation between FA and antibody (Ab) titre, and no correlation between FA and clinical severity: only sera with a high or intermediate Ab titre were effective, whatever the clinical severity of disease. With active sera, AChR loss was about 50% whereas the disappearance of AChR clusters was quite complete, which suggests AChR redistribution induced by MG sera.

  7. 77 FR 57080 - Proposed Agency Information Collection

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-17

    ... DEPARTMENT OF ENERGY Energy Information Administration Proposed Agency Information Collection AGENCY: U.S. Energy Information Administration (EIA), U.S. Department of Energy. ACTION: Agency Information Collection Activities: Proposed Collection; Notice and Request for Comments. SUMMARY: The EIA...

  8. [Possibility of the species identification using blood stains located on the material evidences and bone fragments with the method of solid phase enzyme immunoassay with "IgG general-EIA-BEST" kit and human immunoglobulin G].

    PubMed

    Sidorov, V L; Shvetsova, I V; Isakova, I V

    2007-01-01

    The authors give the comparative analysis of Russian and foreign forensic medical methods of species character identification of the blood from the stains on the material evidences and bone fragments. It is shown that for this purpose it is feasible to apply human immunoglobulin G (IgG) and solid phase enzyme immunoassay (EIA) with the kit "IgG general-EIA-BEST". In comparison with the methods used in Russia this method is more sensitive, convenient for objective registration and computer processing. The results of experiments shown that it is possible to use the kit "IgG general-EIA-BEST" in forensic medicine for the species character identification of the blood from the stains on the material evidences and bone fragments.

  9. A prospective field evaluation of an enzyme immunoassay: Detection of eastern equine encephalomyelitis virus antigen in pools of Culiseta melanura

    USGS Publications Warehouse

    Scott, T.W.; Olson, J.G.; Lewis, T.E.; Carpenter, J.W.; Lorenz, L.H.; Lembeck, L.A.; Joseph, S.R.; Pagac, B.B.

    1987-01-01

    A prospective field study was conducted to determine the sensitivity and specificity of an enzyme immunoassay (EIA) compared to virus isolation in cell culture for the detection of eastern equine encephalomyelitis (EEE) virus in naturally infected mosquitoes. A total of 10,811 adult female Culiseta melanura were collected in light traps during 1985 from four locations in Maryland. Eastern equine encephalomyelitis virus was isolated from 5 of 495 mosquito pools in African green monkey kidney and baby hamster kidney cell cultures. All five virus-infected pools were detected by the EIA, and all 490 uninfected pools were correctly scored as not containing virus. The EIA did not produce false positive or false negative results. Results support the assertion of previous researchers that the antigen detection EIA is a rapid, sensitive, specific, and simple alternative to traditional bioassays for the detection of EEE virus in mosquitoes.

  10. Environmental impact assessment as a complement of life cycle assessment. Case study: Upgrading of biogas.

    PubMed

    Morero, Betzabet; Rodriguez, María B; Campanella, Enrique A

    2015-08-01

    This work presents a comparison between an environmental impact assessment (EIA) and a life cycle assessment (LCA) using a case study: upgrading of biogas. The upgrading of biogas is studied using three solvents: water, physical solvent and amine. The EIA follows the requirements of the legislation of Santa Fe Province (Argentina), and the LCA follows ISO 14040. The LCA results showed that water produces a minor impact in most of the considered categories whereas the high impact in the process with amines is the result of its high energy consumptions. The positive results obtained in the EIA (mainly associated with the cultural and socioeconomic components) make the project feasible and all the negative impacts can be mitigated by preventive and remedial measures. From the strengths and weaknesses of each tool, it is inferred that the EIA is a procedure that can complement the LCA. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Under the Microscope: Single-Domain Antibodies for Live-Cell Imaging and Super-Resolution Microscopy.

    PubMed

    Traenkle, Bjoern; Rothbauer, Ulrich

    2017-01-01

    Single-domain antibodies (sdAbs) have substantially expanded the possibilities of advanced cellular imaging such as live-cell or super-resolution microscopy to visualize cellular antigens and their dynamics. In addition to their unique properties including small size, high stability, and solubility in many environments, sdAbs can be efficiently functionalized according to the needs of the respective imaging approach. Genetically encoded intrabodies fused to fluorescent proteins (chromobodies) have become versatile tools to study dynamics of endogenous proteins in living cells. Additionally, sdAbs conjugated to organic dyes were shown to label cellular structures with high density and minimal fluorophore displacement making them highly attractive probes for super-resolution microscopy. Here, we review recent advances of the chromobody technology to visualize localization and dynamics of cellular targets and the application of chromobody-based cell models for compound screening. Acknowledging the emerging importance of super-resolution microscopy in cell biology, we further discuss advantages and challenges of sdAbs for this technology.

  12. Targeting human prostate cancer with 111In-labeled D2B IgG, F(ab')2 and Fab fragments in nude mice with PSMA-expressing xenografts.

    PubMed

    Lütje, Susanne; van Rij, Catharina M; Franssen, Gerben M; Fracasso, Giulio; Helfrich, Wijnand; Eek, Annemarie; Oyen, Wim J; Colombatti, Marco; Boerman, Otto C

    2015-01-01

    D2B is a new monoclonal antibody directed against an extracellular domain of prostate-specific membrane antigen (PSMA), which is overexpressed in prostate cancer. The potential of D2B IgG, and F(ab')2 and Fab fragments of this antibody for targeting prostate cancer was determined in mice bearing subcutaneous prostate cancer xenografts. The optimal time point for imaging was determined in biodistribution and microSPECT imaging studies with (111)In-D2B IgG, (111)In-capromab pendetide, (111)In-D2B F(ab')2 and (111)In-D2B Fab fragments in mice with PSMA-expressing LNCaP and PSMA-negative PC3 tumors at several time points after injection. All (111)In-labeled antibody formats specifically accumulated in the LNCaP tumors, with highest uptake of (111)In-D2B IgG and (111)In-capromab pendetide at 168 h p.i. (94.8 ± 19.2% injected dose per gram (ID/g) and 16.7 ± 2.2% ID/g, respectively), whereas uptake of (111)In-D2B F(ab')2 and (111)In-D2B Fab fragments peaked at 24 h p.i. (12.1 ± 3.0% ID/g and 15.1 ± 2.9% ID/g, respectively). Maximum LNCaP tumor-to-blood ratios were 13.0 ± 2.3 (168 h p.i.), 6.2 ± 0.7 (24 h p.i.), 23.0 ± 4.0 (24 h p.i.) and 4.5 ± 0.6 (168 h p.i.) for (111)In-D2B IgG, (111)In-F(ab')2, (111)In-Fab and (111)In-capromab pendetide, respectively. LNCaP tumors were clearly visualized with microSPECT with all antibody formats. This study demonstrates the feasibility of D2B IgG, F(ab')2 and Fab fragments for targeting PSMA-expressing prostate cancer xenografts. Copyright © 2014 John Wiley & Sons, Ltd.

  13. UK and Italian EIA systems: A comparative study on management practice and performance in the construction industry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bassi, Andrea, E-mail: ab395@bath.co.uk; Howard, Robert, E-mail: robhoward@constcom.demon.co.uk; Geneletti, Davide, E-mail: davide.geneletti@ing.unitn.it

    This study evaluates and contrasts the management practice and the performance that characterise Environmental Impact Assessments (EIA) in Italy and in the UK. The methodology relies on the investigation of six carefully selected case studies, critically reviewed by referring to EIA and project design information, as well as collecting the opinion of key project participants. The study focuses on the construction industry and on specific key sectors like infrastructure for transport and renewable energy and commercial and tourism development. A main term of reference for the analyses has been established by critically reviewing international literature so as to outline commonmore » good practice, requirements for the enhancement of sustainability principles and typically incurred drawbacks. The proposed approach enhances transfer of knowledge and of experiences between the analyzed contexts and allows the provision of guidelines for practitioners. Distinctive differences between the UK and the Italian EIA systems have been detected for pivotal phases and elements of EIA, like screening, scoping, analysis of alternatives and of potential impacts, definition of mitigation strategies, review, decision making, public participation and follow up. - Highlights: Black-Right-Pointing-Pointer The Italian and the UK Environmental Impact Assessment systems are compared. Black-Right-Pointing-Pointer The research is centred on the construction industry. Black-Right-Pointing-Pointer Issues and shortcomings are analysed by investigating six case studies. Black-Right-Pointing-Pointer Integration of EIA with sustainability principles is appraised. Black-Right-Pointing-Pointer General guidelines are provided to assist practitioners in the two national contexts.« less

  14. Evaluation of flow cytometric HIT assays in relation to an IgG-Specific immunoassay and clinical outcome.

    PubMed

    Kerényi, Adrienne; Beke Debreceni, Ildikó; Oláh, Zsolt; Ilonczai, Péter; Bereczky, Zsuzsanna; Nagy, Béla; Muszbek, László; Kappelmayer, János

    2017-09-01

    Heparin-induced thrombocytopenia (HIT) is a severe side effect of heparin treatment caused by platelet activating IgG antibodies generated against the platelet factor 4 (PF4)-heparin complex. Thrombocytopenia and thrombosis are the leading clinical symptoms of HIT. The clinical pretest probability of HIT was evaluated by the 4T score system. Laboratory testing of HIT was performed by immunological detection of antibodies against PF4-heparin complex (EIA) and two functional assays. Heparin-dependent activation of donor platelets by patient plasma was detected by flow cytometry. Increased binding of Annexin-V to platelets and elevated number of platelet-derived microparticles (PMP) were the indicators of platelet activation. EIA for IgG isotype HIT antibodies was performed in 405 suspected HIT patients. Based on negative EIA results, HIT was excluded in 365 (90%) of cases. In 40 patients with positive EIA test result functional tests were performed. Platelet activating antibodies were detected in 17 cases by Annexin V binding. PMP count analysis provided nearly identical results. The probability of a positive flow cytometric assay result was higher in patients with elevated antibody titer. 71% of patients with positive EIA and functional assay had thrombosis. EIA is an important first line laboratory test in the diagnosis of HIT; however, HIT must be confirmed by a functional test. Annexin V binding and PMP assays using flow cytometry are functional HIT tests convenient in a clinical diagnostic laboratory. The positive results of functional assays may predict the onset of thrombosis. © 2016 International Clinical Cytometry Society. © 2016 International Clinical Cytometry Society.

  15. Seismo-Ionospheric Coupling as Intensified EIA Observed by Satellite Electron Density and GPS-TEC Data

    NASA Astrophysics Data System (ADS)

    Ryu, K.; Jangsoo, C.; Kim, S. G.; Jeong, K. S.; Parrot, M.; Pulinets, S. A.; Oyama, K. I.

    2014-12-01

    Examples of intensified EIA features temporally and spatially related to large earthquakes observed by satellites and GPS-TEC are introduced. The precursory, concurrent, and ex-post enhancements of EIA represented by the equatorial electron density, which are thought to be related to the M8.7 Northern Sumatra earthquake of March 2005, the M8.0 Pisco earthquake of August 2007, and the M7.9 Wenchuan Earthquake of 12 May 2008, are shown with space weather condition. Based on the case studies, statistical analysis on the ionospheric electron density data measured by the Detection of Electro-Magnetic Emissions Transmitted from Earthquake Regions satellite (DEMETER) over a period of 2005-2010 was executed in order to investigate the correlation between seismic activity and equatorial plasma density variations. To simplify the analysis, three equatorial regions with frequent earthquakes were selected and then one-dimensional time series analysis between the daily seismic activity indices and the EIA intensity indices were performed for each region with excluding the possible effects from the geomagnetic and solar activity. The statistically significant values of the lagged cross-correlation function, particularly in the region with minimal effects of longitudinal asymmetry, indicate that some of the very large earthquakes with M > 7.0 in the low latitude region can accompany observable seismo-ionospheric coupling phenomena in the form of EIA enhancements, even though the seismic activity is not the most significant driver of the equatorial ionospheric evolution. The physical mechanisms of the seismo-ionospheric coupling to explain the observation and the possibility of earthquake prediction using the EIA intensity variation are discussed.

  16. Ultrasonic atomization and subsequent desolvation for monoclonal antibody (mAb) to the glycoprotein (GP) IIIa receptor into drug eluting stent.

    PubMed

    Wang, G X; Luo, L L; Yin, T Y; Li, Y; Jiang, T; Ruan, C G; Guidoin, R; Chen, Y P; Guzman, R

    2010-01-01

    An eluting-stent system with mAb dispersed in the PLLA (poly (L-lactic acid)) was validated in vitro. Specifically designed spray equipment based on the principle of ultrasonic atomization was used to produce a thin continuous PLLA (poly (L-lactic acid)) polymer coating incorporating monoclonal antibody (mAb). This PLLA coating was observed in light microscopy (LM) and scanning electron microscopy (SEM). The concentration of the monoclonal antibody (mAb) to the platelet glycoprotein (GP) IIIa receptor and the eluting rate were then measured by a radioisotope technique with (125)I-labelled GP IIIa mAb. An in vitro perfusion circuit was designed to evaluate the release rates at different velocities (10 or 20 ml min(-1)). The PLLA coating was thin and transparent, uniformly distributed on the surface of the stent. Three factors influenced its thickness: PLLA concentration, duration and gas pressure. The concentration of mAb was influenced by the duration of absorption and the concentration of the mAb solution; the maximum was 1662.23 + or - 38.83 ng. The eluting rate was fast for the first 2 h, then decreased slowly and attained 80% after 2 weeks. This ultrasonic atomization spray equipment and technological process to prepare protein eluting-stents were proved to be effective and reliable.

  17. Biological cell controllable patch-clamp microchip

    NASA Astrophysics Data System (ADS)

    Penmetsa, Siva; Nagrajan, Krithika; Gong, Zhongcheng; Mills, David; Que, Long

    2010-12-01

    A patch-clamp (PC) microchip with cell sorting and positioning functions is reported, which can avoid drawbacks of random cell selection or positioning for a PC microchip. The cell sorting and positioning are enabled by air bubble (AB) actuators. AB actuators are pneumatic actuators, in which air pressure is generated by microheaters within sealed microchambers. The sorting, positioning, and capturing of 3T3 cells by this type of microchip have been demonstrated. Using human breast cancer cells MDA-MB-231 as the model, experiments have been demonstrated by this microchip as a label-free technical platform for real-time monitoring of the cell viability.

  18. Radioiodine Labeled Anti-MIF McAb: A Potential Agent for Inflammation Imaging

    PubMed Central

    Zhang, Chao; Hou, Gui-hua; Han, Jian-kui; Song, Jing; Liang, Ting

    2007-01-01

    Macrophage migration inhibitory factor (MIF) is a proinflammatory cytokine that may play a role in the pathogenesis of inflammation. Radiolabeled anti-MIF McAb can be used to detect in vivo inflammatory changes. The objective of this study was to investigate in vivo biology of radioiodinated anti-MIF McAb using the inflammation model mice. Anti-MIF McAb was radioiodinated with NaI125 by Iodogen method. Animal models were induced in the mice by intramuscular injection of S. aureus, E. coli, and turpentine oil. The biodistribution studies with radioiodinated anti-MIF McAb were performed on inflammation mice. The relationship between inflammatory lesions and anti-MIF McAb binding was investigated using the percent of injected dose per gram tissue (% ID/g) of tissue samples and whole-body autoradiography. The radioactivity of I125-anti-MIF McAb in the inflammatory tissue increased gradually for three inflammation models. The highest uptake was found in S. aureus group and the lowest was in E. coli group. The uptake in turpentine oil group was average. Whole-body autoradiography showed that all inflammation foci could be visualized clearly from 24 hours after injection, but 48 hours images were much clearer in accordance with the high T/NT ratio. These results demonstrate the ability of radioiodinated anti-MIF McAb to measure in vivo inflammatory events represented by high expression of MIF and suggests that radiolabeled anti-MIF McAb warrants further investigation as a potential inflammation-seeking agent for imaging to detect inflammatory disorders. PMID:18317509

  19. Comparison of a commercial Varicella Zoster glycoprotein IgG enzyme immunoassay with a reference time resolved fluorescence immunoassay (VZV TRFIA) for measuring VZV IgG in sera from pregnant women, sera sent for confirmatory testing and pre and post vOka vaccination sera from healthcare workers.

    PubMed

    Maple, P A C; Breuer, J; Quinlivan, M; Kafatos, G; Brown, K E

    2012-03-01

    Recently, a commercial, standardised VZV IgG glycoprotein EIA, Binding Site VaccZyme™VZV glycoprotein IgG low level EIA (VaccZyme™EIA) has become available. The VaccZyme™EIA is more robust and user friendly than the reference VZV time-resolved fluorescence immunoassay (VZV TRFIA). To assess the usefulness of the VaccZyme™EIA in the diagnostic laboratory by comparing VZV IgG levels generated by both assays on serum panels representing, non-vaccinated, and vOka vaccinated populations. Sera from non-vaccinated individuals were tested; 248 from pregnant women, 117 from various patient groups referred to the Virus Reference Department for confirmatory VZV IgG testing and 102 from healthcare workers enrolled in a study (ROVE) of antibody/IgG response to vOka. From the ROVE study, 282 post vaccination sera were tested; 108 and 101 collected at six weeks post first and second doses of vOka, respectively, and 73 collected at 18 month follow-up. Sensitivities and specificities (equivocals treated as negatives) of the VaccZyme™EIA for sera from pregnant women were 97.8% (95% CI: [94.6%, 99.4%]) and 96.8% (95% CI: [89.0%, 99.6%]), respectively, and for sera referred for confirmatory testing were 81.2% (95% CI: [71.2%, 88.8%]) and 96.9% (95% CI: [83.8%, 99.9%]), respectively, and for ROVE baseline sera were 54.2% (95% CI: [32.8%, 74.4%]) and 100% (95% CI: [95.4%, 100.0%]), respectively. For the post vOka serum panels sensitivities of the VaccZyme™EIA ranged from 65.3% (95% CI: [50.4%, 78.3%]) to 80.4% (95% CI: [71.1%, 87.8%]). Specificities were all 100%. Correlation with VZV TRFIA was high and agreement varied between the serum panels tested. VaccZyme™EIA is recommended for detecting VZV IgG in sera from non-vaccinated populations; however, caution is advised when measuring post vOka VZV IgG levels. Copyright © 2011 Elsevier B.V. All rights reserved.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Macintosh, Andrew, E-mail: andrew.macintosh@anu.edu.au; Waugh, Lauren

    Concerns about the effectiveness of environmental impact assessment (EIA) have prompted proposals to improve its performance by limiting the discretion of decision-makers in screening. To investigate whether such proposals are likely to generate the desired results, we conducted an evaluation of the screening process under the Australian government's EIA regime from its introduction on 16 July 2000 to 30 June 2013 (study period). Almost 1 in 5 ‘particular manner’ decisions—a type of screening decision under the regime—were found to be unlawful. The extent of non-compliance is explained on the basis of convenience. The department was required to assess a largemore » number of projects under tight timeframes and with limited resources, while being pressured by proponents to allow their projects to bypass EIA. These pressures resulted in the development of an informal custom whereby the formal compensatory mitigation restrictions were frequently ignored. The results highlight the relative significance of formal and informal institutions in EIA. Formal EIA rules typically provide a mere outline of the process. The informal institutions adopted by administrators often have a greater influence on how the process operates and what it achieves. - Highlights: • Concerns about the effectiveness of environmental impact assessment (EIA) have prompted proposals to improve its performance by limiting the discretion of decision-makers in screening. • To investigate whether such proposals are likely to generate the desired results, we conducted an evaluation of the Australian government's screening process, looking at the extent of compliance with a formal prohibition on the consideration of compensatory mitigation. • Almost 1 in 5 ‘particular manner’ decisions – a type of screening decision under the regime – were found to be unlawful (with a 95% confidence interval of between 1:4 and 1:7) because of a failure to abide by the compensatory mitigation restrictions. For urban development actions, the ratio between lawful and unlawful particular manner decisions was worse than 1:1. • The extent of non-compliance is explained on the basis of convenience. Budget and interest group pressures resulted in the development of an informal custom whereby the formal compensatory mitigation restrictions were ignored. • The results highlight the relative significance of formal and informal institutions in EIA. Formal EIA rules typically provide a mere outline of the process. The informal institutions adopted by administrators often have a greater influence on how the process operates and what it achieves.« less

  1. In vivo characterization of the novel CD44v6-targeting Fab fragment AbD15179 for molecular imaging of squamous cell carcinoma: a dual-isotope study

    PubMed Central

    2014-01-01

    Background Patients with squamous cell carcinoma in the head and neck region (HNSCC) offer a diagnostic challenge due to difficulties to detect small tumours and metastases. Imaging methods available are not sufficient, and radio-immunodiagnostics could increase specificity and sensitivity of diagnostics. The objective of this study was to evaluate, for the first time, the in vivo properties of the radiolabelled CD44v6-targeting fragment AbD15179 and to assess its utility as a targeting agent for radio-immunodiagnostics of CD44v6-expressing tumours. Methods The fully human CD44v6-targeting Fab fragment AbD15179 was labelled with 111In or 125I, as models for radionuclides suitable for imaging with SPECT or PET. Species specificity, antigen specificity and internalization properties were first assessed in vitro. In vivo specificity and biodistribution were then evaluated in tumour-bearing mice using a dual-tumour and dual-isotope setup. Results Both species-specific and antigen-specific binding of the conjugates were demonstrated in vitro, with no detectable internalization. The in vivo studies demonstrated specific tumour binding and favourable tumour targeting properties for both conjugates, albeit with higher tumour uptake, slower tumour dissociation, higher tumour-to-blood ratio and higher CD44v6 sensitivity for the 111In-labelled fragment. In contrast, the 125I-Fab demonstrated more favourable tumour-to-organ ratios for liver, spleen and kidneys. Conclusions We conclude that AbD15179 efficiently targets CD44v6-expressing squamous cell carcinoma xenografts, and particularly, the 111In-Fab displayed high and specific tumour uptake. CD44v6 emerges as a suitable target for radio-immunodiagnostics, and a fully human antibody fragment such as AbD15179 can enable further clinical imaging studies. PMID:24598405

  2. Generation and characterization of monoclonal antibodies against Giardia muris trophozoites.

    PubMed

    Heyworth, M F; Ho, K E; Pappo, J

    1989-11-01

    Mouse monoclonal antibodies (mAb) were produced against Giardia muris trophozoite surface antigens. To generate B-cell hybridomas, P3/NS1/1-Ag4-1 myeloma cells were fused with splenic lymphocytes from BALB/c mice that had been immunized parenterally with G. muris trophozoites. Hybridoma culture supernatants were screened for mAb by flow cytometry of G. muris trophozoites incubated with culture supernatant followed by fluorescein-conjugated anti-mouse IgG and IgM. Flow cytometry showed three types of trophozoite staining by mAb: (i) bright staining of greater than 90% of trophozoites, with aggregation of the organisms; (ii) bright staining of approximately 90% of trophozoites, with little or no aggregation; (iii) dull staining of approximately 20% of trophozoites, without aggregation. Western blotting of mAb on G. muris trophozoite antigens separated by polyacrylamide gel electrophoresis showed that a mAb exhibiting the third of these flow cytometry staining patterns recognized trophozoite antigens of MW approximately 31,000 and 35,000. Immunoprecipitation studies indicated that the same mAb specifically precipitated two 125I-labelled trophozoite surface antigens of MW approximately 30,000. Monoclonal antibodies generated in this study may facilitate the purification and biochemical characterization of trophozoite antigens that are targets for protective intestinal antibody in G. muris-infected mice.

  3. Fluorine-18 Labeling of the HER2-Targeting Single-Domain Antibody 2Rs15d Using a Residualizing Label and Preclinical Evaluation.

    PubMed

    Zhou, Zhengyuan; Vaidyanathan, Ganesan; McDougald, Darryl; Kang, Choong Mo; Balyasnikova, Irina; Devoogdt, Nick; Ta, Angeline N; McNaughton, Brian R; Zalutsky, Michael R

    2017-12-01

    Our previous studies with F-18-labeled anti-HER2 single-domain antibodies (sdAbs) utilized 5F7, which binds to the same epitope on HER2 as trastuzumab, complicating its use for positron emission tomography (PET) imaging of patients undergoing trastuzumab therapy. On the other hand, sdAb 2Rs15d binds to a different epitope on HER2 and thus might be a preferable vector for imaging in these patients. The aim of this study was to evaluate the tumor targeting of F-18 -labeled 2Rs15d in HER2-expressing breast carcinoma cells and xenografts. sdAb 2Rs15d was labeled with the residualizing labels N-succinimidyl 3-((4-(4-[ 18 F]fluorobutyl)-1H-1,2,3-triazol-1-yl)methyl)-5-(guanidinomethyl)benzoate ([ 18 F]RL-I) and N-succinimidyl 4-guanidinomethyl-3-[ 125 I]iodobenzoate ([ 125 I]SGMIB), and the purity and HER2-specific binding affinity and immunoreactivity were assessed after labeling. The biodistribution of I-125- and F-18-labeled 2Rs15d was determined in SCID mice bearing subcutaneous BT474M1 xenografts. MicroPET/x-ray computed tomograph (CT) imaging of [ 18 F]RL-I-2Rs15d was performed in this model and compared to that of nonspecific sdAb [ 18 F]RL-I-R3B23. MicroPET/CT imaging was also done in an intracranial HER2-positive breast cancer brain metastasis model after administration of 2Rs15d-, 5F7-, and R3B23-[ 18 F]RL-I conjugates. [ 18 F]RL-I was conjugated to 2Rs15d in 40.8 ± 9.1 % yield and with a radiochemical purity of 97-100 %. Its immunoreactive fraction (IRF) and affinity for HER2-specific binding were 79.2 ± 5.4 % and 7.1 ± 0.4 nM, respectively. [ 125 I]SGMIB was conjugated to 2Rs15d in 58.4 ± 8.2 % yield and with a radiochemical purity of 95-99 %; its IRF and affinity for HER2-specific binding were 79.0 ± 12.9 % and 4.5 ± 0.8 nM, respectively. Internalized radioactivity in BT474M1 cells in vitro for [ 18 F]RL-I-2Rs15d was 43.7 ± 3.6, 36.5 ± 2.6, and 21.7 ± 1.2 % of initially bound radioactivity at 1, 2, and 4 h, respectively, and was similar to that seen for [ 125 I]SGMIB-2Rs15d. Uptake of [ 18 F]RL-I-2Rs15d in subcutaneous xenografts was 16-20 %ID/g over 1-3 h. Subcutaneous tumor could be clearly delineated by microPET/CT imaging with [ 18 F]RL-I-2Rs15d but not with [ 18 F]RL-I-R3B23. Intracranial breast cancer brain metastases could be visualized after intravenous administration of both [ 18 F]RL-I-2Rs15d and [ 18 F]RL-I-5F7. Although radiolabeled 2Rs15d conjugates exhibited lower tumor cell retention both in vitro and in vivo than that observed previously for 5F7, given that it binds to a different epitope on HER2 from those targeted by the clinically utilized HER2-targeted therapeutic antibodies trastuzumab and pertuzumab, F-18-labeled 2Rs15d has potential for assessing HER2 status by PET imaging after trastuzumab and/or pertuzumab therapy.

  4. A novel antiplatelet antibody therapy that induces cAMP-dependent endocytosis of the GPVI/Fc receptor γ-chain complex

    PubMed Central

    Takayama, Hiroshi; Hosaka, Yoshitaka; Nakayama, Kazuyuki; Shirakawa, Kamon; Naitoh, Katsuki; Matsusue, Tomokazu; Shinozaki, Mikihiko; Honda, Motoyasu; Yatagai, Yukiko; Kawahara, Tetsushi; Hirose, Jiro; Yokoyama, Tooru; Kurihara, Michiru; Furusako, Shoji

    2008-01-01

    Platelet adhesion to vascular subendothelium, mediated in part by interactions between collagen and glycoprotein VI (GPVI) complexed with Fc receptor γ-chain, is crucial for thrombus formation. Antiplatelet therapy benefits patients with various thrombotic and ischemic diseases, but the safety and efficacy of existing treatments are limited. Recent data suggest GPVI as a promising target for a novel antiplatelet therapy, for example, GPVI-specific Abs that deplete GPVI from the surface of platelets. Here, we characterized GPVI-specific auto-Abs (YA-Abs) from the first reported patient with ongoing platelet GPVI deficiency caused by the YA-Abs. To obtain experimentally useful human GPVI–specific mAbs with characteristics similar to YA-Abs, we generated human GPVI–specific mouse mAbs and selected 2 representative mAbs, mF1201 and mF1232, whose binding to GPVI was inhibited by YA-Abs. In vitro, mF1201, but not mF1232, induced human platelet activation and GPVI shedding, and mF1232 inhibited collagen-induced human platelet aggregation. Administration of mF1201 and mF1232 to monkeys caused GPVI immunodepletion with and without both significant thrombocytopenia and GPVI shedding, respectively. When a human/mouse chimeric form of mF1232 (cF1232) was labeled with a fluorescent endocytosis probe and administered to monkeys, fluorescence increased in circulating platelets and surface GPVI was lost. Loss of platelet surface GPVI mediated by cF1232 was successfully reproduced in vitro in the presence of a cAMP-elevating agent. Thus, we have characterized cAMP-dependent endocytosis of GPVI mediated by a human GPVI–specific mAb as what we believe to be a novel antiplatelet therapy. PMID:18382762

  5. Department of Health and Human Services Semiannual Regulatory Agenda

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-20

    ... Manufacturing Practice in Manufacturing, Packing, Labeling, or Holding 0910-AB88 Operations for Dietary Supplements 341 Over-the-Counter (OTC) Drug Review--Cough/Cold (Nasal Decongestant) Products 0910-AF34 342... repeated incidents in which cryogenic containers of harmful industrial gases have been connected to medical...

  6. 40 CFR 211.110-2 - National security exemptions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... ABATEMENT PROGRAMS PRODUCT NOISE LABELING General Provisions § 211.110-2 National security exemptions. (a) A new product which is produced to conform with specifications developed by national security agency... security exemption shall be void ab initio with respect to each new product, originally intended for a...

  7. 77 FR 51791 - Agency Information Collection Extension

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-27

    ... DEPARTMENT OF ENERGY U.S. Energy Information Administration Agency Information Collection Extension AGENCY: U.S. Energy Information Administration (EIA), Department of Energy. ACTION: Notice and request for OMB review and comment. SUMMARY: The EIA has submitted an information collection request to...

  8. The significance for epidemiological studies anti-measles antibody detection examined by enzyme immunoassay (EIA) and plaque reduction neutralization test (PRNT).

    PubMed

    Siennicka, Joanna; Częścik, Agnieszka; Trzcińska, Agnieszka

    2014-01-01

    The paper discusses the role of anti-measles antibodies for protection and significance for epidemiological studies determination of antibodies by different serological methods. The comparison of anti-measles virus antibodies levels measured by enzyme immunoassay (EIA) and Plaque Reduction Neutralization Test (PRNT) was described. It was found that the 200 mIU/ml of anti-measles activity measured by PRNT (level protection against symp- tomatic disease) is equivalent of 636 mIU/ml measured by EIA (Enzygnost®Anti-Measles Virus/IgG, Simens).

  9. Fuel oil and kerosene sales 1995

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1996-09-01

    This publication contains the 1995 survey results of the ``Annual Fuel Oil and Kerosene Sales Report`` (Form EIA-821). This is the seventh year that the survey data have appeared in a separate publication. Except for the kerosene and on-highway diesel information, data presented in Tables 1 through 12 (Sales of Fuel Oil and Kerosene) present results of the EIA-821 survey. Tables 13 through 24 (Adjusted Sales of Fuel Oil and Kerosene) include volumes that are based on the EIA-821 survey but have been adjusted to equal the product supplied volumes published in the Petroleum Supply Annual (PSA). 24 tabs.

  10. Comparison of Selected EIA-782 Data With Other Data Sources

    EIA Publications

    2012-01-01

    This article compares annual average prices reported from the EIA-782 survey series for residential No. 2 distillate, on-highway diesel fuel, retail regular motor gasoline, refiner No. 2 fuel oil for resale, refiner No. 2 diesel fuel for resale, refiner regular motor gasoline for resale, and refiner kerosene-type jet fuel for resale with annual average prices reported by other sources. In terms of volume, it compares EIA-782C Prime Supplier annual volumes for motor gasoline (all grades), distillate fuel oil, kerosene-type jet fuel and residual fuel oil with annual volumes from other sources.

  11. Exogenous insulin antibody syndrome (EIAS): a clinical syndrome associated with insulin antibodies induced by exogenous insulin in diabetic patients.

    PubMed

    Hu, Xiaolei; Chen, Fengling

    2018-01-01

    Insulin has been used for diabetes therapy and has achieved significant therapeutic effect. In recent years, the use of purified and recombinant human insulin preparations has markedly reduced, but not completely suppressed, the incidence of insulin antibodies (IAs). IAs induced by exogenous insulin in diabetic patients is associated with clinical events, which is named exogenous insulin antibody syndrome (EIAS). The present review is based on our research and summarizes the characterization of IAs, the factors affecting IA development, the clinical significance of IAs and the treatments for EIAS. © 2018 The authors.

  12. Exogenous insulin antibody syndrome (EIAS): a clinical syndrome associated with insulin antibodies induced by exogenous insulin in diabetic patients

    PubMed Central

    Hu, Xiaolei

    2018-01-01

    Insulin has been used for diabetes therapy and has achieved significant therapeutic effect. In recent years, the use of purified and recombinant human insulin preparations has markedly reduced, but not completely suppressed, the incidence of insulin antibodies (IAs). IAs induced by exogenous insulin in diabetic patients is associated with clinical events, which is named exogenous insulin antibody syndrome (EIAS). The present review is based on our research and summarizes the characterization of IAs, the factors affecting IA development, the clinical significance of IAs and the treatments for EIAS. PMID:29233817

  13. Screening for EIA in India: enhancing effectiveness through ecological carrying capacity approach.

    PubMed

    Rajaram, T; Das, Ashutosh

    2011-01-01

    Developing countries across the world have embraced the policy of high economic growth as a means to reduce poverty. This economic growth largely based on industrial output is fast degrading the ecosystems, jeopardizing their long term sustainability. Environmental Impact Assessment (EIA) has long been recognized as a tool which can help in protecting the ecosystems and aid sustainable development. The Screening guidelines for EIA reflect the level of commitment the nation displays towards tightening its environmental protection system. The paper analyses the screening process for EIA in India and dissects the rationale behind the exclusions and thresholds set in the screening process. The screening process in India is compared with that of the European Union with the aim of understanding the extent of deviations from a screening approach in the context of better economic development. It is found that the Indian system excludes many activities from the purview of screening itself when compared to the EU. The constraints responsible for these exclusions are discussed and the shortcomings of the current command and control system of environmental management in India are also explained. It is suggested that an ecosystem carrying capacity based management system can provide significant inputs to enhance the effectiveness of EIA process from screening to monitoring. Copyright © 2010 Elsevier Ltd. All rights reserved.

  14. Electromagnetically Induced Absorption (EIA) and a ``Twist'' on Nonlinear Magneto-optical Rotation (NMOR) with Cold Atoms

    NASA Astrophysics Data System (ADS)

    Kunz, Paul; Meyer, David; Quraishi, Qudsia

    2015-05-01

    Within the class of nonlinear optical effects that exhibit sub-natural linewidth features, electromagnetically induced transparency (EIT) and nonlinear magneto-optical rotation (NMOR) stand out as having made dramatic impacts on various applications including atomic clocks, magnetometry, and single photon storage. A related effect, known as electromagnetically induced absorption (EIA), has received less attention in the literature. Here, we report on the first observation of EIA in cold atoms using the Hanle configuration, where a single laser beam is used to both pump and probe the atoms while sweeping a magnetic field through zero along the beam direction. We find that, associated with the EIA peak, a ``twist'' appears in the corresponding NMOR signal. A similar twist has been previously noted by Budker et al., in the context of warm vapor optical magnetometry, and was ascribed to optical pumping through nearby hyperfine levels. By studying this feature through numerical simulations and cold atom experiments, thus rendering the hyperfine levels well resolved, we enhance the understanding of the optical pumping mechanism behind it, and elucidate its relation to EIA. Finally, we demonstrate a useful application of these studies through a simple and rapid method for nulling background magnetic fields within our atom chip apparatus.

  15. Mandated monitoring of post-project impacts in the Czech EIA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Branis, Martin; Christopoulos, Stamatios

    2005-04-15

    Altogether, 801 documents of consent (50% of all) issued under the EIA Act No. 244/1992 by the competent authorities in the Czech Republic between 1993 and 2001 were studied. The aim of the analysis was to find and characterize conditions prescribing to the developer to perform ex-ante and ex-post monitoring of potential impacts of projects submitted for approval. It was found that each of the studied documents (standpoints) contained on average three to four conditions prescribing to collect data on various environmental factors during the preparation, implementation and/or operation phase of the development in question. The number of monitoring conditionsmore » contained in the standpoints issued by the Ministry of Environment as well as by the District Offices increased during the period studied from about two to five per project indicating a growing interest in and/or need to obtaining such data. Even though there is a good legal background for collecting monitoring data from implementation and operation phase of new developments, the Czech EIA Act (similarly as EIA acts in other countries) does not provide any practical background for this activity. Without relevant institutional, personal and financial support the possibility to impose post-project monitoring to the developer remains rather a challenge to, not advantage of the Czech EIA Act.« less

  16. Suppression of synthesis of an IgG subclass in a persistent viral infection.

    PubMed Central

    McGuire, T C

    1976-01-01

    Comparison of immunoglobulin levels of nine horses before and after infection with equine infectious anaemia (EIA) virus demonstrated a significant depression of serum IgG(T) at 2 months (P less than 0-001) and at 1 year (P less than 0-01) after infection. In contrast, the levels of IgGa were significantly increased at both times after infection. Another sixteen horses with EIA for 1-4 months were examined and there was also significant depression (P less than 0-001) of IgG(T) when compared to pre-infection levels. No significant changes in IgG(T), IgGa and IgM were noted in fourteen normal horses housed for 2-7 months in the same manner as infected horses. Following DNP immunization there was a significant (P less than 0-02) decrease in the amount of IgG(T) antibody produced in five horses with EIA when compared to five normal horses. Metabolism studies with iodinated IgG(T) showed a significant (P less than 0-001) decrease in synthesis of this immunoglobulin in EIA-infected horses when compared to normal horses. Amounts of IgGa synthesized were similar in the two groups. Thus, persistent EIA viral infection suppresses the synthesis of IgG(T), an IgG subclass, without suppressing IgGa. PMID:814077

  17. Excretion of Hepatitis A Virus (HAV) in Adults: Comparison of Immunologic and Molecular Detection Methods and Relationship between HAV Positivity and Infectivity in Tamarins

    PubMed Central

    Polish, Louis B.; Robertson, Betty H.; Khanna, Bhawna; Krawczynski, Krzysztof; Spelbring, John; Olson, Fred; Shapiro, Craig N.

    1999-01-01

    Fecal excretion of hepatitis A virus (HAV) in 18 patients with HAV infection was evaluated by enzyme immunoassay (EIA) to detect viral antigen and by reverse transcription-PCR amplification followed by ethidium bromide staining (PCR-ETBr) or nucleic acid hybridization (PCR-NA) to detect viral genetic material. A gradation of sensitivity was observed in the detection of virus by the three methods. In persons who had detectable virus, serial stool samples were found to be positive by EIA for up to 24 days after the peak elevation of liver enzymes. Viral genetic material could be detected by PCR-ETBr for up to 34 days and by PCR-NA for up to 54 days after the peak elevation of liver enzymes. After intravenous inoculation of tamarins with stool suspensions categorized as highly reactive for HAV (positive by EIA, PCR-ETBr, and PCR-NA), moderately reactive (positive by PCR-ETBr and PCR-NA), or weakly reactive (positive by PCR-NA), only tamarins infected with highly reactive stool suspensions (EIA positive) developed HAV infection. We conclude that positivity of stool specimens for HAV by PCR-ETBr or PCR-NA indicates a lower potential for infectivity, compared to that of EIA-positive stools. PMID:10523563

  18. Target-specific NMR detection of protein-ligand interactions with antibody-relayed 15N-group selective STD.

    PubMed

    Hetényi, Anasztázia; Hegedűs, Zsófia; Fajka-Boja, Roberta; Monostori, Éva; Kövér, Katalin E; Martinek, Tamás A

    2016-12-01

    Fragment-based drug design has been successfully applied to challenging targets where the detection of the weak protein-ligand interactions is a key element. 1 H saturation transfer difference (STD) NMR spectroscopy is a powerful technique for this work but it requires pure homogeneous proteins as targets. Monoclonal antibody (mAb)-relayed 15 N-GS STD spectroscopy has been developed to resolve the problem of protein mixtures and impure proteins. A 15 N-labelled target-specific mAb is selectively irradiated and the saturation is relayed through the target to the ligand. Tests on the anti-Gal-1 mAb/Gal-1/lactose system showed that the approach is experimentally feasible in a reasonable time frame. This method allows detection and identification of binding molecules directly from a protein mixture in a multicomponent system.

  19. A novel colloidal gold labeled antigen for the detection of Deoxynivalenol using an immunochromatographic assay method

    NASA Astrophysics Data System (ADS)

    Jin, Yu; Liu, Renrong; Zhu, Lixin; Chen, Zhenzhen

    2017-11-01

    In this paper, an immunochromatographic assay card was developed for the detection of DON in feed and cereals using a novel colloidal gold labeling method. For the colloidal gold immunochromatographic rapid detection (GICD) card, a monoclonal antibody DON-mAb and a goat anti-chicken IgY were drawn on NC membrane as the test line (T line) and the control line (C line) respectively. A gold labeled DON-CBSA conjugate and a gold labeled chicken IgY were sprayed onto the conjugate pad. The GICD card has cut-off levels of 50ng/mL for DON, which is invulnerable to matrix interference, and applicable to a wide range of samples. The GICD detecting results of feed and grain samples were compared with the results of ELISA testing, which showed good consistency.

  20. PET-based compartmental modeling of (124)I-A33 antibody: quantitative characterization of patient-specific tumor targeting in colorectal cancer.

    PubMed

    Zanzonico, Pat; Carrasquillo, Jorge A; Pandit-Taskar, Neeta; O'Donoghue, Joseph A; Humm, John L; Smith-Jones, Peter; Ruan, Shutian; Divgi, Chaitanya; Scott, Andrew M; Kemeny, Nancy E; Fong, Yuman; Wong, Douglas; Scheinberg, David; Ritter, Gerd; Jungbluth, Achem; Old, Lloyd J; Larson, Steven M

    2015-10-01

    The molecular specificity of monoclonal antibodies (mAbs) directed against tumor antigens has proven effective for targeted therapy of human cancers, as shown by a growing list of successful antibody-based drug products. We describe a novel, nonlinear compartmental model using PET-derived data to determine the "best-fit" parameters and model-derived quantities for optimizing biodistribution of intravenously injected (124)I-labeled antitumor antibodies. As an example of this paradigm, quantitative image and kinetic analyses of anti-A33 humanized mAb (also known as "A33") were performed in 11 colorectal cancer patients. Serial whole-body PET scans of (124)I-labeled A33 and blood samples were acquired and the resulting tissue time-activity data for each patient were fit to a nonlinear compartmental model using the SAAM II computer code. Excellent agreement was observed between fitted and measured parameters of tumor uptake, "off-target" uptake in bowel mucosa, blood clearance, tumor antigen levels, and percent antigen occupancy. This approach should be generally applicable to antibody-antigen systems in human tumors for which the masses of antigen-expressing tumor and of normal tissues can be estimated and for which antibody kinetics can be measured with PET. Ultimately, based on each patient's resulting "best-fit" nonlinear model, a patient-specific optimum mAb dose (in micromoles, for example) may be derived.

  1. A new radiopharmaceutical compound (131I-PR81) for radioimmunotherapy of breast cancer: labeling of antibody and its quality control.

    PubMed

    Mohammadnejad, J; Rasaee, M J; Babaei, M H; Paknejad, M; Zahir, M H; Salouti, M; Rajabi, A Bitarafan; Mazidi, M

    2010-01-01

    PR81 is a monoclonal antibody that binds with high affinity to MUC1, which is over expressed on breast and other tumors. The objective of this study was to evaluate the application of this antibody against MUC1 as a radioimmunotherapeutical agent. Monoclonal antibody (PR81) against MUC1 was prepared, characterized, purified, and labeled with 131I. The immunoreactivity of radiolabeled mAb PR81with MUC1 (the native protein), BSA-P20 (a 20 amino acid corresponding the tandem repeat of MUC1) and MCF7 cell line were performed by RIA. In vitro stability of radiolabeled mAb in human serum was determined by thin layer chromatography (TLC). Cell toxicity and in vitro internalization studies were performed with the MCF7 cell line, and the tissue biodistribution of the radioiodinated PR81 was evaluated in normal BALB/c mice at 4, 24 and 48 hrs. The tumor imaging was performed in BALB/c mice with breast xenograft tumors at 24 and 72 hr after the complex injection. The labeling efficiency was found to be 59.9% ± 7.9%. MAb-131I conjugates showed high immunoreactivity towards MUC1 protein, BSA-P20 and MCF7 cell line. In vitro stability of the labeled product in human serum was found to be more than %50 over 24 hr. Cell toxicity and in vitro internalization studies showed that the mAb-131I conjugate inhibited 80% growth of the MCF7 cultured cell lines in vitro in a high concentration and up to %60 of the conjugate internalized after 24 h. Biodistribution studies were performed in normal BALB/c mice at 4, 24 and 48 hrs post-injection and no important accumulation was observed in vital organs. The tumors were visualized with high sensitivity after 24 and 72 hr in radioimmunoscintographical studies. These results show that the new radiopharmaceutical may be considered as a promising candidate for therapy of breast cancer.

  2. RETHINKING HUMAN HEALTH IMPACT ASSESSMENT. (R825758)

    EPA Science Inventory

    Most EIA programs around the world require the consideration of human health impacts. Yet relatively few EIA documents adequately address those impacts. This article examines how, why, and to what extent health impacts are analyzed in environmental impact assessments in the U.S. ...

  3. EIA's Natural Gas Production Data

    EIA Publications

    2009-01-01

    This special report examines the stages of natural gas processing from the wellhead to the pipeline network through which the raw product becomes ready for transportation and eventual consumption, and how this sequence is reflected in the data published by the Energy Information Administration (EIA).

  4. Colloidal gold-McAb probe-based rapid immunoassay strip for simultaneous detection of fumonisins in maize.

    PubMed

    Yao, Jingjing; Sun, Yaning; Li, Qingmei; Wang, Fangyu; Teng, Man; Yang, Yanyan; Deng, Ruiguang; Hu, Xiaofei

    2017-05-01

    Fumonisins are a kind of toxic and carcinogenic mycotoxin. A rapid immunochromatographic test strip has been developed for simultaneous detection of fumonisin B 1 , B 2 and B 3 (FB 1 , FB 2 and FB 3 ) in maize based on colloidal gold-labelled monoclonal antibody (McAb) against FB 1 probe. The anti-FB 1 McAb (2E11-H3) was produced through immunisation and cell fusion, and identified as high affinity, specificity and sensitivity. The cross-reaction ratios with fumonisin B 2 and B 3 were accordingly 385% and 72.4%, while none with other analogues. The colloid gold-labelled anti-FB 1 McAb probe was successfully prepared and used for establishing the immunochromatographic strip. The test strip showed high sensitivity and specificity, the IC 50 for FB 1 was 58.08 ng mL -1 , LOD was 11.24 ng mL -1 , calculated from standard curve. Moreover, the test strip exhibited high cross-reactivity with FB 2 and FB 3 , and could be applied to the simultaneous detection of FBs (FB 1 :FB 2 :FB 3 = 12:4:1) in maize sample with high accuracy and precision. The average recoveries of FBs in maize ranged from 90.42% to 95.29%, and CVs were 1.25-3.77%. The results of the test strip for FBs samples showed good correlation with high-performance liquid chromatography analysis. The immunochromatographic test strip could be employed in the rapid simultaneous detection of FB 1 , FB 2 and FB 3 in maize samples on-site. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  5. An Ultrasensitive Electrochemical Immunosensor for HIV p24 Based on Fe₃O₄@SiO₂ Nanomagnetic Probes and Nanogold Colloid-Labeled Enzyme-Antibody Copolymer as Signal Tag.

    PubMed

    Gan, Ning; Du, Xiaowen; Cao, Yuting; Hu, Futao; Li, Tianhua; Jiang, Qianli

    2013-03-25

    An ultrasensitive portable electrochemical immunosensor for human immunodeficiency virus p24 (HIV p24) antigen detection has been developed, whereby the detection sensitivity was 1000 times higher than that of the ELISA method. Firstly, a novel HRP enzyme-antibody copolymer (EV-p24 Ab2) was synthesized through an EnVision regent (EV, a dextrin amine skeleton anchoring more than 100 molecules of HRP and 15 molecules of anti IgG), then incubated in the secondary antibody of p24. Secondly, the copolymer was immobilized on the gold nanocolloids (AuNPs) to fabricate a novel signal tag (AuNPs/EV-p24 Ab2). Subsequently, a sandwich-type immunoreaction would take place between the capture probe (silicon dioxide-coated magnetic Fe₃O₄ nanoparticles (MNPs) labeled with the primary p24 antibody (MNPs-p24 Ab1)), p24 (different concentrations) and the signal tag [AuNPs/EV-p24 Ab2)] to form the immunocomplex. Finally, the immunocomplex was absorbed on the surface of screen printed carbon electrode (SPCE) by a magnet and immersed in the o-hydroxyl phenol (HQ) and H₂O₂. The large amounts of HRP on the signal tag can catalyze the oxidation of HQ by H₂O₂, which can induce an amplified reductive current. Moreover, the capture probe could improve the accumulation ability of p24 and facilitate its separation from the substrate through the magnet. Under optimal conditions, the proposed immunoassay exhibited good sensitivity to p24 within a certain concentration range from 0.001 to 10.00 ng/mL, with a detection limit of 0.5 pg/mL (S/N = 3). The proposed method can be used for real-time and early detection of HIV-infected people.

  6. The application of anti-ESAT-6 monoclonal antibody fluorescent probe in ex vivo near-infrared fluorescence imaging in mice with pulmonary tuberculosis.

    PubMed

    Feng, Feng; Zhang, Haoling; Zhu, Zhaoqin; Li, Cong; Shi, Yuxin; Zhang, Zhiyong

    2014-09-01

    Here, we aimed to assess the feasibility of anti-ESAT-6 monoclonal antibody (mAb) coupling with IR783 and rhodamine fluorescent probe in the detection of ESAT-6 expression in tuberculosis tissue of mice using near-infrared fluorescence imaging. IR783 and rhodamine were conjugated to the anti-ESAT-6 mAb or IgG. Mice in the experimental group were injected with fluorescence-labeled mAb probe, and mice in the control group were injected with fluorescence-labeled non-specific IgG antibody. Twenty-four hours later, the lung tissue of mice was examined using ex vivo near-infrared fluorescence imaging. In addition, the contrast-to-noise ratio (CNR) was calculated by measuring the signal intensities of the pulmonary lesions, normal lung tissue and background noise. The frozen lung tissue section was examined under fluorescence microscopy and compared with hemoxylin and eosin (HE) staining. The ex vivo near-infrared fluorescence imaging showed that the fluorescence signal in the lung tuberculosis lesions in the experimental group was significantly enhanced, whereas there was only a weak fluorescence signal or even no fluorescence signal in the control group. CNR values were 64.40 ± 7.02 (n = 6) and 8.75 ± 3.87 (n = 6), respectively (t = 17.01, p < 0.001). The fluorescence accumulation distribution detected under fluorescence microscopy was consistent with HE staining of the tuberculosis region. In conclusion, anti-ESAT-6 mAb fluorescent probe could target and be applied in specific ex vivo imaging of mice tuberculosis, and may be of further use in tuberculosis in living mice. Copyright © 2013 John Wiley & Sons, Ltd.

  7. 40 CFR 204.5-2 - National security exemptions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... exemptions. (a) A new product which is produced to conform with specifications developed by a national security agency, and so labeled or marked on the outside of the container and on the product itself, shall... national security exemption shall be void ab initio with respect to each new product, originally intended...

  8. 77 FR 234 - Rule Concerning Disclosures Regarding Energy Consumption and Water Use of Certain Home Appliances...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-04

    ... FEDERAL TRADE COMMISSION 16 CFR Part 305 RIN 3084-AB03 Rule Concerning Disclosures Regarding Energy Consumption and Water Use of Certain Home Appliances and Other Products Required Under the Energy Policy and Conservation Act (``Appliance Labeling Rule'') AGENCY: Federal Trade Commission. ACTION...

  9. Evaluation of Antiatherogenic Properties of Ezetimibe Using 3H-Labeled Low-Density-Lipoprotein Cholesterol and 99mTc-cAbVCAM1-5 SPECT in ApoE-/- Mice Fed the Paigen Diet.

    PubMed

    Dumas, Laurent S; Briand, François; Clerc, Romain; Brousseau, Emmanuel; Montemagno, Christopher; Ahmadi, Mitra; Bacot, Sandrine; Soubies, Audrey; Perret, Pascale; Riou, Laurent M; Devoogdt, Nick; Lahoutte, Tony; Barone-Rochette, Gilles; Fagret, Daniel; Ghezzi, Catherine; Sulpice, Thierry; Broisat, Alexis

    2017-07-01

    The addition of ezetimibe, an intestinal cholesterol absorption inhibitor, to statin therapy has recently shown clinical benefits in the Improved Reduction of Outcomes: Vytorin Efficacy International Trial by reducing low-density-lipoprotein (LDL) cholesterol levels more than statin therapy alone. Here, we investigated the mechanisms by which inhibition of intestinal cholesterol absorption might contribute to the clinically observed reduction in cardiovascular events by evaluating its effect on inflammatory plaque development in apolipoprotein E -/- mice. Methods: Apolipoprotein E -/- mice were fed the Paigen diet (1.25% cholesterol, 0.5% cholic acid, and 15% fat) without or with ezetimibe (7 mg/kg/d) for 6 wk. In a first set of mice ( n = 15), we intravenously injected 3 H-cholesteryl oleate-labeled human LDL to test whether ezetimibe promotes LDL-derived cholesterol fecal excretion. In a second set ( n = 20), we used the imaging agent 99m Tc-cAbVCAM1-5 to evaluate expression of an inflammatory marker, vascular cell adhesion molecule 1 (VCAM-1), in atherosclerotic plaques. In a third set ( n = 21), we compared VCAM-1 expression with 99m Tc-cAbVCAM1-5 uptake in various tissues. Results: Mice treated with ezetimibe showed a 173% higher LDL-cholesteryl ester plasma disappearance rate ( P < 0.001 vs. control) after 3 H-cholesteryl oleate-labeled LDL injection. At 96 h after injection, the hepatic fraction of 3 H-tracer was 61% lower in mice treated with ezetimibe ( P < 0.001). Meanwhile, LDL-derived 3 H-cholesterol excretion in the feces was 107% higher ( P < 0.001). The antiatherogenic effect of ezetimibe monitored by 99m Tc-cAbVCAM1-5 SPECT showed a 49% reduction in aortic tracer uptake (percentage injected dose per cubic centimeter, 0.95 ± 0.04 vs. 1.87 ± 0.11; P < 0.01). In addition to hypercholesterolemia, the proinflammatory Paigen diet significantly increased VCAM-1 expression with respect to the control group in various tissues, including the aorta, and this expression correlated strongly with 99m Tc-cAbVCAM1-5 uptake ( r = 0.75; P < 0.05). Conclusion: Inhibition of intestinal cholesterol absorption with ezetimibe promotes antiatherosclerotic effects through increased LDL cholesterol catabolism and LDL-derived cholesterol fecal excretion and reduces inflamed atherosclerotic plaques. These mechanisms may contribute to the benefits of adding ezetimibe to a statin therapy. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  10. Detection of anti-nuclear antibody by immunofluorescence assay and enzyme immunoassay in childhood systemic lupus erythematosus: experience from Bangladesh.

    PubMed

    Dipti, Tanjeem Rabika; Azam, Mohammad Shaiful; Sattar, Mohammad Humayun; Rahman, Shahana Akhter

    2012-02-01

    Systemic lupus erythematosus (SLE) is a multisystem, chronic but often episodic, autoimmune disease that is characterized by the presence of antinuclear antibodies (ANA). The criteria set by American College of Rheumatology are widely used for diagnosis of SLE. Elevation of ANA titer is the most sensitive of the ACR criteria. There are different methods for detection of ANA. Indirect immunofluorescence (ANA-IFA) and enzyme immunoassay (ANA-EIA) are commonly used methods. The sensitivity of ANA-IFA using HEp-2 cell substrate is 90-100% in systemic rheumatic diseases. In Bangladesh most of the laboratories use ANA-EIA for detection of ANA. As the sensitivity of ANA-EIA is lower than ANA-IFA it might be that we are missing many cases of ANA positivity in childhood SLE cases. To detect ANA by immunofluorescence assay using HEp-2 cell substrate and enzyme immunoassay in childhood SLE and to compare the diagnostic performance of these methods. This is a cross-sectional analytical study. A total of 40 patients were enrolled. Among them 20 were childhood SLE cases. Another 20 patients of childhood rheumatic diseases other than SLE were taken as the disease control group. In childhood SLE cases, 100% were ANA-positive by IFA and 55% were ANA positive by EIA. The sensitivity of ANA-IFA was 100%. In contrast, sensitivity of ANA-EIA was 55%.   ANA-IFA is superior to ANA-EIA for detection of ANA in childhood SLE patients. ANA-IFA should be the primary screening test for children with clinical features suggestive of SLE. © 2011 The Authors. International Journal of Rheumatic Diseases © 2011 Asia Pacific League of Associations for Rheumatology and Blackwell Publishing Asia Pty Ltd.

  11. Improved detection of acute parvovirus B19 infection by immunoglobulin M EIA in combination with a novel antigen EIA.

    PubMed

    Corcoran, A; Kerr, S; Elliott, G; Koppelman, M; Doyle, S

    2007-10-01

    Although parvovirus B19 is a significant blood product contaminant, few methods other than polymerase chain reaction (PCR) have been developed to detect the presence of the virus. A B19 antigen enzyme immunoassay (EIA) has been developed and the sensitivity of detection is ascertained using dilutions of the B19 capsid protein VP2 and 10-fold dilutions of B19 viraemic serum. Once the assay cut-off was established, a panel of viraemic donations (n = 70) was screened by the antigen EIA. The B19 immunoglobulin M (IgM) and IgG status of these specimens was also determined. During screening of blood donor units by quantitative PCR, 70 individuals were identified with levels of B19 DNA greater than 10(6) IU/ml at the time of blood donation. The sensitivity of the B19 antigen EIA was estimated to be equivalent to between 10(8) and 10(9) IU/ml B19 DNA or 1-10 pg/ml of recombinant capsid protein. B19 detection was significantly enhanced when viraemic specimens were pretreated with a low pH proprietary reagent. Unlike other virus-detection assays, detection of the B19 antigen was not affected by the presence of B19 IgM or IgG antibodies. In addition, the assay was capable of detecting all three genotypes of human erythrovirus. Combined specimen analysis by the B19 antigen assay and a B19 IgM assay facilitated the detection of 91% of acute B19 infections in the test population. In combination with B19 IgM detection, application of the B19 antigen EIA is a flexible and efficient method of detecting recent B19 infection and can be used as an alternative to PCR.

  12. Variation in the limit-of-detection of the ProSpecT Campylobacter microplate enzyme immunoassay in stools spiked with emerging Campylobacter species.

    PubMed

    Bojanić, Krunoslav; Midwinter, Anne Camilla; Marshall, Jonathan Craig; Rogers, Lynn Elizabeth; Biggs, Patrick Jon; Acke, Els

    2016-08-01

    Campylobacter enteritis in humans is primarily associated with C. jejuni/coli infection. The impact of other Campylobacter spp. is likely to be underestimated due to the bias of culture methods towards Campylobacter jejuni/coli diagnosis. Stool antigen tests are becoming increasingly popular and appear generally less species-specific. A review of independent studies of the ProSpecT® Campylobacter Microplate enzyme immunoassay (EIA) developed for C. jejuni/coli showed comparable diagnostic results to culture methods but the examination of non-jejuni/coli Campylobacter spp. was limited and the limit-of-detection (LOD), where reported, varied between studies. This study investigated LOD of EIA for Campylobacter upsaliensis, Campylobacter hyointestinalis and Campylobacter helveticus spiked in human stools. Multiple stools and Campylobacter isolates were used in three different concentrations (10(4)-10(9)CFU/ml) to reflect sample heterogeneity. All Campylobacter species evaluated were detectable by EIA. Multivariate analysis showed LOD varied between Campylobacter spp. and faecal consistency as fixed effects and individual faecal samples as random effects. EIA showed excellent performance in replicate testing for both within and between batches of reagents, in agreement between visual and spectrophotometric reading of results, and returned no discordance between the bacterial concentrations within independent dilution test runs (positive results with lower but not higher concentrations). This study shows how limitations in experimental procedures lead to an overestimation of consistency and uniformity of LOD for EIA that may not hold under routine use in diagnostic laboratories. Benefits and limitations for clinical practice and the influence on estimates of performance characteristics from detection of multiple Campylobacter spp. by EIA are discussed. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Characterisation and validation of an enzyme-immunoassay for the non-invasive assessment of faecal glucocorticoid metabolites in cheetahs (Acinonyx jubatus).

    PubMed

    Ludwig, C; Wachter, B; Silinski-Mehr, S; Ganswindt, A; Bertschinger, H; Hofer, H; Dehnhard, M

    2013-01-01

    The non-invasive measurement of adrenocortical function in cheetahs is an important tool to assess stress in captive and free-ranging individuals, because stress has been suggested to be one of the causes of poor reproductive performance of captive cheetahs. We tested four enzyme immunoassays (EIA) in two captive cheetahs in Germany using adrenocorticotropic hormone (ACTH) challenges and identified the corticosterone-3-CMO EIA to be most sensitive to the increase in faecal glucocorticoid metabolite (fGCM) concentrations after the ACTH challenge. This EIA performed also well in five captive cheetahs in South Africa. The fGCM concentrations across all seven cheetahs increased within 24h by 681% compared to the baseline levels prior to ACTH. Storage of faecal samples at 0-4°C did not strongly affect fGCM concentrations within 24h, simplifying sample collection when immediate storage at -20°C is not feasible. The two cheetahs in Germany also received an injection of [(3)H]cortisol to characterise fGCMs in faecal extracts using high-performance liquid chromatography (HPLC) immunograms. HPLC fractions were measured for their radioactivity and immunoreactive fGCM concentrations with the corticosterone-3-CMO EIA, respectively. The results revealed a polar peak of radiolabelled cortisol metabolites co-eluting with the major peak of immunoreactive fGCMs. Thus, our EIA measured substantial amounts of fGCMs corresponding to the radioactive peaks. The peaks were of higher polarity than native cortisol and corticosterone, suggesting that the metabolites were conjugated, which was confirmed by solvolysis of the HPLC fractions. Our results show that the corticosterone-3-CMO EIA is a reliable tool to assess fGCMs in cheetahs. Copyright © 2012 Elsevier Inc. All rights reserved.

  14. Harnessing opportunities for good governance of health impacts of mining projects in Mongolia: results of a global partnership.

    PubMed

    Pfeiffer, Michaela; Vanya, Delgermaa; Davison, Colleen; Lkhagvasuren, Oyunaa; Johnston, Lesley; Janes, Craig R

    2017-06-27

    The Sustainable Development Goals call for the effective governance of shared natural resources in ways that support inclusive growth, safeguard the integrity of the natural and physical environment, and promote health and well-being for all. For large-scale resource extraction projects -- e.g. in the mining sector -- environmental regulations and in particular environmental impact assessments (EIA) provide an important but insufficiently developed avenue to ensure that wider sustainable development issues, such as health, have been considered prior to the permitting of projects. In recognition of the opportunity provided in EIA to influence the extent to which health issues would be addressed in the design and delivery of mining projects, an international and intersectoral partnership, with the support of WHO and public funds from Canadian sources, engaged over a period of six years in a series of capacity development activities and knowledge translation/dissemination events aimed at influencing policy change in the extractives sector so as to include consideration of human health impacts. Early efforts significantly increased awareness of the need to include health considerations in EIAs. Coupling effective knowledge translation about health in EIA with the development of networks that fostered good intersectoral partnerships, this awareness supported the development and implementation of key pieces of legislation. These results show that intersectoral collaboration is essential, and must be supported by an effective conceptual understanding about which methods and models of impact assessment, particularly for health, lend themselves to integration within EIA. The results of our partnership demonstrate that when specific conditions are met, integrating health into the EIA system represents a promising avenue to ensure that mining activities contribute to wider sustainable development goals and objectives.

  15. Increased pain sensitivity but normal function of exercise induced analgesia in hip and knee osteoarthritis--treatment effects of neuromuscular exercise and total joint replacement.

    PubMed

    Kosek, E; Roos, E M; Ageberg, E; Nilsdotter, A

    2013-09-01

    To assess exercise induced analgesia (EIA) and pain sensitivity in hip and knee osteoarthritis (OA) and to study the effects of neuromuscular exercise and surgery on these parameters. The dataset consisted of knee (n = 66) and hip (n = 47) OA patients assigned for total joint replacement at Lund University Hospital undergoing pre-operative neuromuscular exercise and 43 matched controls. Sensitivity to pressure pain was assessed by pressure algometry at 10 sites. Subjects were then instructed to perform a standardized static knee extension. Pressure pain thresholds (PPTs) were assessed at the contracting quadriceps muscle (Q) and at the resting deltoid muscle (D) before and during contraction. The relative increase in PPTs during contraction was taken as a measure of localized (Q) or generalized (D) EIA. Patients were assessed at baseline, following on average 12 weeks of neuromuscular exercise and 3 months following surgery. We found a normal function of EIA in OA patients at baseline. Previous studies have reported beneficial effects of physical exercise on pain modulation in healthy subjects. However, no treatment effects on EIA were seen in OA patients despite the increase in muscle strength following neuromuscular exercise and reduced pain following surgery. Compared to controls, OA patients had increased pain sensitivity and no beneficial effects on pain sensitivity were seen following treatment. To our knowledge, this is the first study of EIA in OA patients. Despite increased pain sensitivity, OA patients had a normal function of EIA. Copyright © 2013 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  16. Statistical analysis of the correlation between the equatorial electrojet and the occurrence of the equatorial ionisation anomaly over the East African sector

    NASA Astrophysics Data System (ADS)

    Mungufeni, Patrick; Bosco Habarulema, John; Migoya-Orué, Yenca; Jurua, Edward

    2018-06-01

    This study presents statistical quantification of the correlation between the equatorial electrojet (EEJ) and the occurrence of the equatorial ionisation anomaly (EIA) over the East African sector. The data used were for quiet geomagnetic conditions (Kp ≤ 3) during the period 2011-2013. The horizontal components, H, of geomagnetic fields measured by magnetometers located at Addis Ababa, Ethiopia (dip lat. ˜ 1° N), and Adigrat, Ethiopia (dip lat. ˜ 6° N), were used to determine the EEJ using differential techniques. The total electron content (TEC) derived from Global Navigation Satellite System (GNSS) signals using 19 receivers located along the 30-40° longitude sector was used to determine the EIA strengths over the region. This was done by determining the ratio of TEC over the crest to that over the trough, denoted as the CT : TEC ratio. This technique necessitated characterisation of the morphology of the EIA over the region. We found that the trough lies slightly south of the magnetic equator (0-4° S). This slight southward shift of the EIA trough might be due to the fact that over the East African region, the general centre of the EEJ is also shifted slightly south of the magnetic equator. For the first time over the East African sector, we determined a threshold daytime EEJ strength of ˜ 40 nT that is mostly associated with prominent EIA occurrence during a high solar activity period. The study also revealed that there is a positive correlation between daytime EEJ and EIA strengths, with a strong positive correlation occurring during the period 13:00-15:00 LT.

  17. Aspergillus Galactomannan Enzyme Immunoassay and Quantitative PCR for Diagnosis of Invasive Aspergillosis with Bronchoalveolar Lavage Fluid

    PubMed Central

    Musher, Benjamin; Fredricks, David; Leisenring, Wendy; Balajee, S. Arunmozhi; Smith, Caitlin; Marr, Kieren A.

    2004-01-01

    Invasive pulmonary aspergillosis (IPA) is frequent and often fatal in hematopoietic stem cell transplant patients. Diagnosis requires microbiological or histopathologic demonstration of the organism in tissues; however, cultivation of Aspergillus species from respiratory secretions has low diagnostic sensitivity. Assays to detect Aspergillus antigen or DNA in bronchoalveolar lavage (BAL) fluid could facilitate earlier diagnosis, thereby guiding optimal therapy and obviating the need for additional costly and potentially morbid diagnostic evaluation. We evaluated the performance of a galactomannan enzyme immunoassay (GM EIA; Bio-Rad) by using a range of index cutoffs to define positivity and a quantitative PCR (qPCR) assay for the detection of Aspergillus species from BAL samples of patients with proven and probable IPA (case patients; n = 49) and without IPA (control patients; n = 50). The sensitivity of the GM EIA was 61% with an index cutoff of 1.0 and 76% with an index cutoff of 0.5; the corresponding specificities were 98 and 94%, respectively. The sensitivity and specificity of qPCR assay were 67 and 100%, respectively. The sensitivity with 22 culture-negative BAL specimens from patients with IPA was 41% for GM EIA with an index cutoff of 1.0, 59% for GM EIA with an index cutoff of 0.5, and 36% for qPCR assay. GM EIA indices and DNA quantities corresponded to BAL fungal burdens, with culture-positive samples having larger amounts of antigen and DNA compared to culture-negative samples. GM EIA and qPCR assay add to the sensitivity of BAL for diagnosing IPA in high-risk patients, with excellent specificity. Adjunctive use of these tests may reduce dependence on invasive diagnostic procedures. PMID:15583275

  18. Exercise-induced albuminuria is related to metabolic syndrome.

    PubMed

    Greenberg, Sharon; Shenhar-Tsarfaty, Shani; Rogowski, Ori; Shapira, Itzhak; Zeltser, David; Weinstein, Talia; Lahav, Dror; Vered, Jaffa; Tovia-Brodie, Oholi; Arbel, Yaron; Berliner, Shlomo; Milwidsky, Assi

    2016-06-01

    Microalbuminuria (MA) is a known marker for endothelial dysfunction and future cardiovascular events. Exercise-induced albuminuria (EiA) may precede the appearance of MA. Associations between EiA and metabolic syndrome (MS) have not been assessed so far. Our aim was to investigate this association in a large sample of apparently healthy individuals with no baseline albuminuria. This was a cross-sectional study of 2,027 adults with no overt cardiovascular diseases who took part in a health survey program and had no baseline MA. Diagnosis of MS was based on harmonized criteria. All patients underwent an exercise test (Bruce protocol), and urinary albumin was measured before and after the examination. Urinary albumin-to-creatinine ratio (ACR) values before and after exercise were 0.40 (0.21-0.89) and 1.06 (0.43-2.69) mg/g for median (interquartile range) respectively. A total of 394 (20%) subjects had EiA; ACR rose from normal rest values (0.79 mg/g) to 52.28 mg/g after exercise (P < 0.001); this effect was not shown for the rest of the study population. EiA was related to higher prevalence of MS (13.8% vs. 27.1%, P < 0.001), higher metabolic equivalents (P < 0.001), higher baseline blood pressure (P < 0.001), and higher levels of fasting plasma glucose, triglycerides, and body mass index (P < 0.001). Multivariate binary logistic regression model showed that subjects with MS were 98% more likely to have EiA (95% confidence interval: 1.13-3.46, P = 0.016). In conclusion, EiA in the absence of baseline MA is independently related to MS. Copyright © 2016 the American Physiological Society.

  19. Evaluation and reporting of enzyme immunoassay determinations of antibody to herpes simplex virus in sera and cerebrospinal fluid.

    PubMed Central

    Cremer, N E; Cossen, C K; Hanson, C V; Shell, G R

    1982-01-01

    Several methods for evaluating and reporting enzyme immunoassay (EIA) determinations of antibody to herpes simplex virus derived from one dilution of single serum samples were studied. An EIA ratio method for serological evidence of current infection from paired serum samples was also evaluated. Optical density (OD) of the reaction at a 1:100 serum dilution and estimated titers obtained by reference of the OD of the serum dilution to a standard curve were compared to the corresponding plotted EIA titer obtained by titration to endpoint. Neither the OD per se nor the estimated titer was completely predictive of the plotted titer (correlation coefficient [r] of 0.824 and 0.817, respectively), and they provided only a semiquantitative measurement of antibody concentration. For an antibody status report, however, OD would be sufficient if related to the cutoff value as an EIA index (OD of sample divided by cutoff OD for positive specimens). The OD of the EIA reaction at a single dilution (1:5) of cerebrospinal fluid, on the other hand, correlated quite well with the titer obtained by titration (r = 0.950). For serological diagnosis of current infection, the OD ratio of convalescence-phase/acute-phase sera was determined at several dilutions. A ratio of greater than or equal to 1.54 was calculated as a reliable index for a significant rise in antibody concentration and compatible with current infection. By determining the convalescent-phase/acute-phase serum ratio at two dilutions, 1:100 and 1:1,000, the EIA ratio method appeared to be a sensitive as or more sensitive than, complement fixation in diagnosing current infection. PMID:6284791

  20. Coping with Exercise-Induced Asthma in Sports.

    ERIC Educational Resources Information Center

    Katz, Roger M.

    1987-01-01

    This article reviews the history of research on exercise-induced asthma (EIA) and the pathophysiology of the condition, including its development and influencing factors. Four groups of drugs that are effective against EIA--theopyhlline, beta-adrenergic agents, cromolyn sodium, and anticholinergics--are discussed. (Author/CB)

  1. EIA Completes Corrections to Drilling Activity Estimates Series

    EIA Publications

    1999-01-01

    The Energy Information Administration (EIA) has published monthly and annual estimates of oil and gas drilling activity since 1978. These data are key information for many industry analysts, serving as a leading indicator of trends in the industry and a barometer of general industry status.

  2. Precursory enhancement of EIA in the morning sector: Contribution from mid-latitude large earthquakes in the north-east Asian region

    NASA Astrophysics Data System (ADS)

    Ryu, Kwangsun; Oyama, Koh-Ichiro; Bankov, Ludmil; Chen, Chia-Hung; Devi, Minakshi; Liu, Huixin; Liu, Jann-Yenq

    2016-01-01

    To investigate whether the link between seismic activity and EIA (equatorial ionization anomaly) enhancement is valid for mid-latitude seismic activity, DEMETER observations around seven large earthquakes in the north-east Asian region were fully analyzed (M ⩾ 6.8). In addition, statistical analysis was performed for 35 large earthquakes (M ⩾ 6.0) that occurred during the DEMETER observation period. The results suggest that mid-latitude earthquakes do contribute to EIA enhancement, represented as normalized equatorial Ne , and that ionospheric change precedes seismic events, as has been reported in previous studies. According to statistical studies, the normalized equatorial density enhancement is sensitive and proportional to both the magnitude and the hypocenter depth of an earthquake. The mechanisms that can explain the contribution of mid-latitude seismic activity to EIA variation are briefly discussed based on current explanations of the geochemical and ionospheric processes involved in lithosphere-ionosphere interaction.

  3. [Serological and clinical proof of freedom from Equine Infectious Anemia (EIA) in imported and domestic horses in Switzerland].

    PubMed

    Kaiser, A; Meier, H P; Doherr, M G; Perler, L; Zanoni, R; Gerber, V

    2009-04-01

    Since 1991, no cases of Equine Infectious Anemia (EIA) have been reported in Switzerland. Risk factors for introduction of the virus into Switzerland are still present or have even increased as frequent inapparent infections, large numbers of imported horses, (since 2003) absence of compulsory testing prior to importation, EIA cases in surrounding Europe, possible illegal importation of horses, frequent short-term stays, poor knowledge of the disease among horse owners and even veterinarians. The aim of this study was to provide evidence of freedom from EIA in imported and domestic horses in Switzerland. The serum samples from 434 horses imported since 2003 as well as from 232 domestic horses fifteen years of age or older (since older horses have naturally had a longer time of being exposed to the risk of infection) were analysed using a commercially available ELISA test. All samples were seronegative, indicating that the maximum possible prevalence that could have been missed with this sample was 0.5% (95% confidence).

  4. Public participation in environmental impact assessment-implementing the Aarhus Convention

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hartley, Nicola; Wood, Christopher

    This article explores the nature of public participation in the environmental impact assessment (EIA) process in the context of the potential integration of the Aarhus Convention principles into the UK EIA system. Although the Convention advocates 'early' and 'effective' participation, these terms remain undefined and questions persist about exactly how to implement the Aarhus principles. Ten practice evaluation criteria derived from the Aarhus Convention are used to analyse the public participation procedures used in four UK waste disposal EIA case studies. The paper reports the extent to which the practice evaluation criteria were fulfilled, explores the types and effectiveness ofmore » the participation methods used in the EIAs, and highlights some of the key barriers that appear to impede the execution of 'early' and 'effective' participation programmes. It concludes that the Aarhus Convention will undoubtedly lead to a strengthening of participation procedures but that the level of improvement secured will depend upon how its ideals are interpreted and incorporated into legislation and practice.« less

  5. Environmental agreements, EIA follow-up and aboriginal participation in environmental management: The Canadian experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    O'Faircheallaigh, Ciaran

    2007-05-15

    During the last decade a number of environmental agreements (EAs) have been negotiated in Canada involving industry, government and Aboriginal peoples. This article draws on the Canadian experience to consider the potential of such negotiated agreements to address two issues widely recognised in academic and policy debates on environmental impact assessment (EIA) and environmental management. The first relates to the need to secure indigenous participation in environmental management of major projects that affect indigenous peoples. The second and broader issue involves the necessity for specific initiatives to ensure effective follow-up of EIA. The Canadian experience indicates that negotiated environmental agreementsmore » have considerable potential to address both issues. However, if this potential is to be realized, greater effort must be made to develop structures and processes specifically designed to encourage Aboriginal participation; and EAs must themselves provide the financial and other resource required to support EIA follow-up and Aboriginal participation.« less

  6. Is quantitative oestrogen receptor expression useful in the evaluation of the clinical prognosis? Analysis of a homogeneous series of 797 patients with prospective determination of the ER status using simultaneous EIA and IHC.

    PubMed

    Mazouni, Chafika; Bonnier, Pascal; Goubar, Aïcha; Romain, Sylvie; Martin, Pierre-Marie

    2010-10-01

    Oestrogen receptor (ER) determination in breast cancer (BC) is a major yardstick for the prognosis and for response to hormonal therapy (HT). As several techniques have been proposed for ER quantification, the purpose of our study was to assess whether the qualitative or quantitative analysis of ER expression might influence the prognosis and response to treatment. We analysed overall survival (OS) and disease-free survival (DFS) in 797 primary BC cases with ER determination by enzyme immunoassay (EIA) and immunohistochemistry (IHC). The clinical impact according to qualitative or quantitative analysis of ER expression was assessed. Response to HT was evaluated according to quantitative EIA-determined ER expression levels. According to the qualitative analysis of ER expression, patients with EIA-determined and IHC-determined ER-positive tumours had significantly longer OS and DFS (p<0.001). The analysis stratified on quartiles of ER levels showed significantly different outcomes according to EIA- and IHC-determined subgroups. In the group of patients who received adjuvant treatment, 5-year OS was significantly different between the groups, with a clear benefit for the highest EIA-determined ER quartiles (p<0.001). Comparatively, in terms of 5-year DFS, a clear separation was noted between groups for adjuvant treatment (p<0.001). The group with moderate ER+ values was clearly distinct from the ER-negative population. Quantitative ER expression helped to better distinguish the beneficial or detrimental effect of HT within quartiles of ER-expressing tumours. Based on the STEPP analysis which showed a trend towards an ER effect on DFS as a function of HT assignment, we confirm the benefit of HT in patients with a very high EIA-determined ER level and a detrimental impact on negative and weakly positive groups. Quantitative ER expression in BC helps to better discriminate heterogeneity in clinical outcome and response to HT. Copyright © 2010 Elsevier Ltd. All rights reserved.

  7. Equatorial Ionospheric Anomaly (EIA) and comparison with IRI model during descending phase of solar activity (2005-2009)

    NASA Astrophysics Data System (ADS)

    Kumar, Sanjay; Singh, A. K.; Lee, Jiyun

    2014-03-01

    The ionospheric variability at equatorial and low latitude region is known to be extreme as compared to mid latitude region. In this study the ionospheric total electron content (TEC), is derived by analyzing dual frequency Global Positioning System (GPS) data recorded at two stations separated by 325 km near the Indian equatorial anomaly region, Varanasi (Geog latitude 25°, 16/ N, longitude 82°, 59/ E, Geomagnetic latitude 16°, 08/ N) and Kanpur (Geog latitude 26°, 18/ N, longitude 80°, 12/ E, Geomagnetic latitude 17°, 18/ N). Specifically, we studied monthly, seasonal and annual variations as well as solar and geomagnetic effects on the equatorial ionospheric anomaly (EIA) during the descending phase of solar activity from 2005 to 2009. It is found that the maximum TEC (EIA) near equatorial anomaly crest yield their maximum values during the equinox months and their minimum values during the summer. Using monthly averaged peak magnitude of TEC, a clear semi-annual variation is seen with two maxima occurring in both spring and autumn. Results also showed the presence of winter anomaly or seasonal anomaly in the EIA crest throughout the period 2005-2009 only except during the deep solar minimum year 2007-2008. The correlation analysis indicate that the variation of EIA crest is more affected by solar activity compared to geomagnetic activity with maximum dependence on the solar EUV flux, which is attributed to direct link of EUV flux on the formation of ionosphere and main agent of the ionization. The statistical mean occurrence of EIA crest in TEC during the year from 2005 to 2009 is found to around 12:54 LT hour and at 21.12° N geographic latitude. The crest of EIA shifts towards lower latitudes and the rate of shift of the crest latitude during this period is found to be 0.87° N/per year. The comparison between IRI models with observation during this period has been made and comparison is poor with increasing solar activity with maximum difference during the year 2005.

  8. The inclusion of biodiversity in environmental impact assessment: Policy-related progress limited by gaps and semantic confusion.

    PubMed

    Bigard, Charlotte; Pioch, Sylvain; Thompson, John D

    2017-09-15

    Natural habitat loss and fragmentation, as a result of development projects, are major causes of biodiversity erosion. Environmental impact assessment (EIA) is the most commonly used site-specific planning tool that takes into account the effects of development projects on biodiversity by integrating potential impacts into the mitigation hierarchy of avoidance, reduction, and offset measures. However, the extent to which EIA fully address the identification of impacts and conservation stakes associated with biodiversity loss has been criticized in recent work. In this paper we examine the extent to which biodiversity criteria have been integrated into 42 EIA from 2006 to 2016 for small development projects in the Montpellier Metropolitan territory in southern France. This study system allowed us to question how EIA integrates biodiversity impacts on a scale relevant to land-use planning. We examine how biodiversity inclusion has changed over time in relation to new policy for EIA and how the mitigation hierarchy is implemented in practice and in comparison with national guidelines. We demonstrate that the inclusion of biodiversity features into EIA has increased significantly in relation to policy change. Several weaknesses nevertheless persist, including the continued absence of substitution solution assessment, a correct analysis of cumulative impacts, the evaluation of impacts on common species, the inclusion of an ecological network scale, and the lack of monitoring and evaluation measures. We also show that measures for mitigation hierarchy are primarily associated with the reduction of impacts rather than their avoidance, and avoidance and offset measures are often misleadingly proposed in EIA. There is in fact marked semantic confusion between avoidance, reduction and offset measures that may impair stakeholders' understanding. All in all, reconsideration of stakeholders routine practices associated with a more strategic approach towards impact anticipation and avoidance at a land-use planning scale is now necessary for the mitigation hierarchy to become a clear and practical hierarchy for "no net loss" objectives based on conservation priorities. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Bmi-1-targeting suppresses osteosarcoma aggressiveness through the NF-κB signaling pathway

    PubMed Central

    Liu, Jiaguo; Luo, Bin; Zhao, Meng

    2017-01-01

    Bone cancer is one of the most lethal malignancies and the specific causes of tumor initiation are not well understood. B-cell-specific Moloney murine leukemia virus integration site 1 protein (Bmi-1) has been reported to be associated with the initiation and progression of osteosarcoma, and as a prognostic indicator in the clinic. In the current study, a full-length antibody targeting Bmi-1 (AbBmi-1) was produced and the preclinical value of Bmi-1-targeted therapy was evaluated in bone carcinoma cells and tumor xenograft mice. The results indicated that the Bmi-1 expression level was markedly upregulated in bone cancer cell lines, and inhibition of Bmi-1 by AbBmi-1 reduced the invasiveness and migration of osteosarcoma cells. Overexpression of Bmi-1 promoted proliferation and angiogenesis, and increased apoptosis resistance induced by cisplatin via the nuclear factor-κB (NF-κB) signal pathway. In addition, AbBmi-1 treatment inhibited the tumorigenicity of osteosarcoma cells in vivo. Furthermore, AbBmi-1 blocked NF-κB signaling and reduced MMP-9 expression. Furthermore, Bmi-1 promoted osteosarcoma tumor growth, whereas AbBmi-1 significantly inhibited osteosarcoma tumor growth in vitro and in vivo. Notably, AbBmi-1 decreased the percentages of Ki67-positive cells and terminal deoxynucleotidyl transferase dUTP nick end labeling-positive cells in tumors compared with Bmi-1-treated and PBS controls. Notably, MMP-9 and NF-κB expression were downregulated by treatment with AbBmi-1 in MG-63 osteosarcoma cells. In conclusion, the data provides evidence that AbBmi-1 inhibited the progression of osteosarcoma, suggesting that AbBmi-1 may be a novel anti-cancer agent through the inhibition of Bmi-1 via activating the NF-κB pathway in osteosarcoma. PMID:28983587

  10. Copper-doped titanium dioxide nanoparticles as dual-functional labels for fabrication of electrochemical immunosensors.

    PubMed

    Zhang, Sen; Ma, Hongmin; Yan, Liangguo; Cao, Wei; Yan, Tao; Wei, Qin; Du, Bin

    2014-09-15

    Constructions of versatile electroactive labels are key issues in the development of electrochemical immunosensors. In this study, copper-doped titanium dioxide nanoparticle (Cu@TiO2) was synthesized and used as labels for fabrication of sandwich-type electrochemical immunosensors on glassy carbon electrode (GCE). Due to the presence of copper ions, Cu@TiO2 shows a strong response current when coupled to an electrode. The prepared nanocomposite also shows high electrocatalytic activity towards reduction of hydrogen peroxide (H2O2). The dual functionality of Cu@TiO2 enables the fabrication of immunosensor using different detection modes, that is, square wave voltammetry (SWV) or chronoamperometry (CA). While Cu@TiO2 was used as labels of secondary antibodies (Ab2), carboxyl functionalized graphene oxide (CFGO) was used as electrode materials to immobilize primary antibodies (Ab1). Using human immunoglobulin G (IgG) as a model analyte, the immunosensor shows high sensitivity, acceptable stability and good reproducibility for both detection modes. Under optimal conditions, a linear range from 0.1 pg/mL to 100 ng/mL with a detection limit of 0.052 pg/mL was obtained for SWV analysis. For CA analysis, a wider linear range from 0.01 pg/mL to 100 ng/mL and a lower detection limit of 0.0043 pg/mL were obtained. The proposed metal ion-based enzyme-free and noble metal-free immunosensor may have promising applications in clinical diagnoses and many other fields. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Annual Energy Outlook 2016 With Projections to 2040

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None, None

    The Annual Energy Outlook 2016 (AEO2016), prepared by the U.S. Energy Information Administration (EIA), presents long-term projections of energy supply, demand, and prices through 2040. The projections, focused on U.S. energy markets, are based on results from EIA’s National Energy Modeling System (NEMS). NEMS enables EIA to make projections under alternative, internallyconsistent sets of assumptions. The analysis in AEO2016 focuses on the Reference case and 17 alternative cases. EIA published an Early Release version of the AEO2016 Reference case (including U.S. Environmental Protection Agency’s (EPA) Clean Power Plan (CPP)) and a No CPP case (excluding the CPP) in May 2016.

  12. Diagnosing vocal cord dysfunction in young athletes.

    PubMed

    Rhodes, Rea Kae

    2008-12-01

    To provide an overview of the pathophysiology, steps in making a diagnosis, differential diagnosis, and treatment methods for vocal cord dysfunction (VCD) in young athletes. Review of published literature about VCD and exercise-induced asthma (EIA) and a case study. The clinical presentation of VCD is often confusing. A young athlete who is having difficulty "catching his breath" may have more than EIA. Young athletes who have been previously diagnosed with EIA may actually have VCD. The ability to correctly differentiate VCD from other causes of respiratory distress can lead to accurate interventions, save precious time in an acute situation, and promote long-term control of this condition.

  13. Bilateral External Iliac Artery Dissection in a Middle-Aged Male Athlete

    PubMed Central

    Yamanaka, Yasushi; Yoshida, Tetsuya; Nagaoka, Eiki

    2017-01-01

    We present the case of a bilateral external iliac artery (EIA) dissection in a 44-year-old male athlete. The patient was referred to our department for right lower abdominal pain without claudication during single squatting. His athletic history included participation in approximately five athletic events per year. Contrast-enhanced computed tomography (CT) revealed bilateral EIA dissection and right renal infarction. Following medical treatment for his hypertension and considering his medical history, a bilateral EIA replacement with 8-mm Dacron straight grafts was performed on the 24th day after hospital admission. Postoperative contrast-enhanced CT revealed good bilateral graft patency and perfusion following surgery. PMID:29515713

  14. Bilateral External Iliac Artery Dissection in a Middle-Aged Male Athlete.

    PubMed

    Yamanaka, Yasushi; Yoshida, Tetsuya; Nagaoka, Eiki

    2017-12-25

    We present the case of a bilateral external iliac artery (EIA) dissection in a 44-year-old male athlete. The patient was referred to our department for right lower abdominal pain without claudication during single squatting. His athletic history included participation in approximately five athletic events per year. Contrast-enhanced computed tomography (CT) revealed bilateral EIA dissection and right renal infarction. Following medical treatment for his hypertension and considering his medical history, a bilateral EIA replacement with 8-mm Dacron straight grafts was performed on the 24th day after hospital admission. Postoperative contrast-enhanced CT revealed good bilateral graft patency and perfusion following surgery.

  15. Development of a Serological Test for Haemophilus ducreyi for Seroprevalence Studies

    PubMed Central

    Elkins, Christopher; Yi, Kyungcheol; Olsen, Bonnie; Thomas, Christopher; Thomas, Kevin; Morse, Stephen

    2000-01-01

    We developed a new enzyme immunoassay (rpEIA) for use in determining the seroprevalence of chancroid. Three highly conserved outer membrane proteins from Haemophilus ducreyi strain 35000 were cloned, overexpressed, and purified from Escherichia coli for use as antigens in the rpEIA. Serum specimens from patients with and without chancroid were assayed to determine optimum sensitivity and specificity and to establish cutoff values. On the basis of these data, rpEIA was found to be both sensitive and specific when used to test a variety of serum specimens from patients with genital ulcers and urethritis and from healthy blood donors. PMID:10747137

  16. EVMS Self-Surveillance of Remote Handled Low Level Waste (RHLLW) Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nelson, Michael L.; Case, Kimberly; Hergesheimer, Linda

    2013-07-01

    DOE G 413.3-10A, Section 3.a states: “The Contractor has primary responsibility for implementing and maintaining a surveillance program to ensure continued compliance of the system with ANSI/EIA-748B. DOE O 413.3B requires the FPD to ensure the contractor conducts a Self-Surveillance annually. This annual Self-Surveillance,…should cover all 32 guidelines of the ANSI/EIA748B. Documentation of the Self-Surveillance is sent to the CO and the PMSO (copy to OECM) confirming the continued compliance of their EVMS ANSI/EIA748B...” This review, and the associated report, is deemed to satisfy this requirement.

  17. 76 FR 70125 - Agency Information Collection Activities: Submission for OMB Review; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-10

    ... Request. SUMMARY: The EIA has submitted the U.S. Energy Information Administration's Monthly Biodiesel... thousands of dollars). 1. EIA-22M, ``Monthly Biodiesel Production Survey.'' 2. U.S. Energy Information... to collect information from biodiesel producers regarding the following: Plant location, capacity...

  18. EIA Corrects Errors in Its Drilling Activity Estimates Series

    EIA Publications

    1998-01-01

    The Energy Information Administration (EIA) has published monthly and annual estimates of oil and gas drilling activity since 1978. These data are key information for many industry analysts, serving as a leading indicator of trends in the industry and a barometer of general industry status.

  19. Comparison of Multispot EIA with Western blot for confirmatory serodiagnosis of HIV.

    PubMed

    Torian, Lucia V; Forgione, Lisa A; Punsalang, Amado E; Pirillo, Robert E; Oleszko, William R

    2011-12-01

    Recent improvements in the sensitivity of immunoassays (IA) used for HIV screening, coupled with increasing recognition of the importance of rapid point-of-care testing, have led to proposals to adjust the algorithm for serodiagnosis of HIV so that screening and confirmation can be performed using a dual or triple IA sequence that does not require Western blotting for confirmation. One IA that has been proposed as a second or confirmatory test is the Bio-Rad Multispot(®) Rapid HIV-1/HIV-2 Test. This test would have the added advantage of differentiating between HIV-1 and HIV-2 antibodies. To compare the sensitivity and type-specificity of an algorithm combining a 3rd generation enzyme immunoassay (EIA) followed by a confirmatory Multispot with the conventional algorithm that combines a 3rd generation EIA (Bio-Rad GS HIV-1/HIV-2 Plus O EIA) followed by confirmatory Western blot (Bio-Rad GS HIV-1 WB). 8760 serum specimens submitted for HIV testing to the New York City Public Health Laboratory between May 22, 2007, and April 30, 2010, tested repeatedly positive on 3rd generation HIV-1-2+O EIA screening and received parallel confirmatory testing by WB and Multispot (MS). 8678/8760 (99.1%) specimens tested WB-positive; 82 (0.9%) tested WB-negative or indeterminate (IND). 8690/8760 specimens (99.2%) tested MS-positive, of which 14 (17.1%) had been classified as negative or IND by WB. Among the HIV-1 WB-positive specimens, MS classified 26 (0.29%) as HIV-2. Among the HIV-1 WB negative and IND, MS detected 12 HIV-2. MS detected an additional 14 HIV-1 infections among WB negative or IND specimens, differentiated 26 HIV-1 WB positives as HIV-2, and detected 12 additional HIV-2 infections among WB negative/IND. A dual 3rd generation EIA algorithm incorporating MS had equivalent HIV-1 sensitivity to the 3rd generation EIA-WB algorithm and had the added advantage of detecting 12 HIV-2 specimens that were not HIV-1 WB cross-reactors. In this series an algorithm using EIA followed by MS would have resulted in the expedited referral of 38 specimens for HIV-2 testing and 40 specimens for nucleic acid confirmation. Further testing using a combined gold standard of nucleic acid detection and WB is needed to calculate specificity and validate the substitution of MS for WB in the diagnostic algorithm used by a large public health laboratory. Copyright © 2011. Published by Elsevier B.V.

  20. EIA and GC/MS analysis of 8-isoprostane in EBC of children with problematic asthma.

    PubMed

    Carraro, S; Cogo, P E; Isak, I; Simonato, M; Corradi, M; Carnielli, V P; Baraldi, E

    2010-06-01

    Asthmatic airways are characterised by enhanced oxidative stress, which can be studied by measuring biomarkers, such as 8-isoprostane. The aims of the present study were: 1) to measure the concentrations of 8-isoprostane in exhaled breath condensate (EBC) and urine of children with problematic and well-controlled asthma; 2) to compare the concentrations of 8-isoprostane measured by gas chromatographic/negative ion chemical ionisation mass spectrometry (GC/NICI-MS) and by an enzymatic immunoassay (EIA). We recruited 20 asthmatic allergic children, 13 with well-controlled asthma and seven with problematic asthma. They underwent exhaled nitric oxide measurements and spirometry, and both EBC and urine samples were collected. 8-isoprostane was measured in EBC by GC/NICI-MS and EIA. 8-isoprostane concentrations in EBC were significantly higher in children with problematic asthma than in children with well-controlled asthma (p = 0.01). An acceptable reproducibility emerged between GC/NICI-MS and EIA (coefficient of reproducibility 11.5 pg x mL(-1)). 8-isoprostane levels measured in urine did not correlate with those measured in EBC. We showed that 8-isoprostane in EBC was significantly increased in children with problematic asthma, suggesting a role for oxidative stress in this asthma phenotype. In addition we found an acceptable reproducibility of EIA compared to GC/NICI-MS, even if the latter method had higher accuracy.

  1. White Matter Hyperintensities on Brain Magnetic Resonance Imaging in People with Epilepsy: A Hospital-Based Study.

    PubMed

    Mao, Yi-Ting; Goh, Enid; Churilov, Leonid; McIntosh, Anne; Ren, Yi-Fan; O'Brien, Terence J; Davis, Stephen; Dong, Qiang; Yan, Bernard; Kwan, Patrick

    2016-09-01

    We aim to explore whether people with epilepsy have increased white matter hyperintensities (WMHs). Eligible patients were categorized into newly diagnosed epilepsy (NE) and chronic epilepsy (CE); the latter were subdivided to those treated with enzyme-inducing antiepileptic drugs (EIAEDs) with or without non-enzyme-inducing antiepileptic drugs (NEIAEDs) and those with NEIAEDs only. WMHs were measured using age-related white matter changes (ARWMC) scale and compared between patients and healthy control group. Higher scores indicate greater WMH changes. The strengths of associations were estimated as incidence rate ratios (IRRs) with 95% confidence interval (CI). A total of 217 patients were included in the analysis, of whom 67 had NE, 45 had CE treated with NEIAEDs, and 105 had CE treated with EIAEDs. Age was positively associated with ARWMC score (IRR per year, 1.03; 95%CI, 1.03-1.04, P < 0.001). Compared with the healthy control group (n = 23), all patient groups had higher ARWMC score (P < 0.05). The difference was greatest in patients receiving EIAEDs (IRR, 2.13; 95%CI, 1.22-3.70, P = 0.007). WMHs tended to be observed in people with epilepsy, especially in those treated with EIAEDs. People with epilepsy with white matter changes should be evaluated for stroke risk, particularly if they are receiving EIAEDs. © 2016 John Wiley & Sons Ltd.

  2. Implementing the Espoo Convention in transboundary EIA between Germany and Poland

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Albrecht, Eike

    Poland and Germany have a long common border which leads to the necessity to cooperate and consult each other in the case of large-scale projects or infrastructure measures likely to cause negative transboundary effects on the environment. There are already binding provisions for transboundary EIA. In the area of the UN Economic Commission for Europe (UNECE), transboundary EIA is intended to be legally binding for the Member States by the Espoo Convention which was ratified by Germany 8.8.2002 and by Poland 12.6.1997. Due to corresponding directives, the same is applicable in the context of the European Union. In German legislation,more » this issue is regulated by Art. 8 of the Federal EIA Act in regard to transboundary participation of administration and by Art. 9a in respect of transboundary public participation. However, these EIA regulations on transboundary participation do not surpass a certain detail level, as they have to be applied between Germany and all neighbouring states. Therefore both countries decided to agree on more detailed provisions in particular regarding procedural questions. During the 12th German-Polish Environmental Council, Germany and Poland reached an agreement on 11.4.2006 in Neuhardenberg/Brandenburg an agreement upon the implementation of the Espoo Convention, the so called Neuhardenberg Agreement. This article assesses the agreement under consideration of already existing law and discusses major improvements and problems.« less

  3. Human health and wellbeing in environmental impact assessment in New South Wales, Australia: Auditing health impacts within environmental assessments of major projects

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Harris, Patrick J., E-mail: patrick.harris@unsw.edu.a; Harris, Elizabeth, E-mail: e.harris@unsw.edu.a; Thompson, Susan, E-mail: s.thompson@unsw.edu.a

    Internationally the inclusion of health within environmental impact assessment (EIA) has been shown to be limited. While Australian EIA documentation has not been studied empirically to date, deficiencies in practice have been documented. This research developed an audit tool to undertake a qualitative descriptive analysis of 22 Major Project EAs in New South Wales, Australia. Results showed that health and wellbeing impacts were not considered explicitly. They were, however, included indirectly in the identification of traditional public health exposures associated with the physical environment and to a lesser extent the inclusion of social and economic impacts. However, no health datamore » was used to inform any of the assessments, there was no reference to causal pathways between exposures or determinants and physical or mental health effects, and there was no inclusion of the differential distribution of exposures or health impacts on different populations. The results add conceptually and practically to the long standing integration debate, showing that health is in a position to add value to the EIA process as an explicit part of standard environmental, social and economic considerations. However, to overcome the consistently documented barriers to integrating health in EIA, capacity must be developed amongst EIA professionals, led by the health sector, to progress health related knowledge and tools.« less

  4. Bioelectrochemical Magnetic Immunosensing of Trichloropyridinol: A Potential Insecticide Biomarker

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Guodong; Timchalk, Chuck; Lin, Yuehe

    2006-07-01

    A magnetic beads-based bioelectrochemical magnetic immunosensor was developed for the fast and sensitive determination of the trichloropyridinol (TCP) biomarker in environmental samples. After liquid phrase competitive immunoreaction among a limited amount of TCP antibody coated-magnetic beads (Ab-MBs), TCP analyte, and horseradish peroxidase (HRP) labeled TCP (HRP-TCP), a magnet/glassy carbon (MGC) electrode was used to collect a TCP-Abs-MBs and a HRP-TCP-Ab-MBs immunocomplex assembly. The activity of HRP tracers bound to the beads was monitored with highly sensitive square wave voltammetry (SWV) by accumulating an electroactive enzymatic product to the MGC electrode surface under constant potential (0.5 V) during enzymatic reaction inmore » the presence of 3’,3’,5’,5’-tetramethylbenzidine (TMB)-H2O2 substrate solution. The electrochemical characteristics of substrate and product were investigated, and the parameters of the immunoassay were optimized.« less

  5. Generation and characterization of monoclonal antibodies against Giardia muris trophozoites.

    PubMed Central

    Heyworth, M F; Ho, K E; Pappo, J

    1989-01-01

    Mouse monoclonal antibodies (mAb) were produced against Giardia muris trophozoite surface antigens. To generate B-cell hybridomas, P3/NS1/1-Ag4-1 myeloma cells were fused with splenic lymphocytes from BALB/c mice that had been immunized parenterally with G. muris trophozoites. Hybridoma culture supernatants were screened for mAb by flow cytometry of G. muris trophozoites incubated with culture supernatant followed by fluorescein-conjugated anti-mouse IgG and IgM. Flow cytometry showed three types of trophozoite staining by mAb: (i) bright staining of greater than 90% of trophozoites, with aggregation of the organisms; (ii) bright staining of approximately 90% of trophozoites, with little or no aggregation; (iii) dull staining of approximately 20% of trophozoites, without aggregation. Western blotting of mAb on G. muris trophozoite antigens separated by polyacrylamide gel electrophoresis showed that a mAb exhibiting the third of these flow cytometry staining patterns recognized trophozoite antigens of MW approximately 31,000 and 35,000. Immunoprecipitation studies indicated that the same mAb specifically precipitated two 125I-labelled trophozoite surface antigens of MW approximately 30,000. Monoclonal antibodies generated in this study may facilitate the purification and biochemical characterization of trophozoite antigens that are targets for protective intestinal antibody in G. muris-infected mice. Images Figure 2 Figure 3 Figure 4 Figure 5 PMID:2592009

  6. Label-free Fab and Fc affinity/avidity profiling of the antibody complex half-life for polyclonal and monoclonal efficacy screening.

    PubMed

    Read, Thomas; Olkhov, Rouslan V; Williamson, E Diane; Shaw, Andrew M

    2015-09-01

    A unified approach to affinity screening for Fab and Fc interactions of an antibody for its antigen and FcγR receptor has been developed. An antigen array is used for the Fab affinity and cross-reactivity screening and protein A/G proxy is the FcγR receptor. The affinities are derived using a simple 1:1 binding model with a consistent error analysis. The association and dissociation kinetics are measured over optimised times for accurate determination. The Fab/Fc affinities are derived for ten antibodies: mAb-actin (mouse), pAb-BSA (sheep), pAb-collagen V (rabbit), pAb-CRP (goat), mAb-F1 (mouse), mAbs (mouse) 7.3, 12.3, 29.3, 36.3 and 46.3 raised against LcrV in Yersinia pestis. The rate of the dissociation of antigen-antibody complexes relates directly to their immunological function as does the Fc-FcγR complex and a new half-life plot has been defined with a Fab/Fc half-life range of 17-470 min. The upper half-life value points to surface avidity. Two antibodies that are protective as an immunotherapy define a Fab half-life >250 min and an Fc half-life >50 min as characteristics of ideal interactions which can form the basis of an antibody screen for immunotherapy.

  7. Making the Most of Your Tutorial Session.

    ERIC Educational Resources Information Center

    Barboza, Vicki Carter

    This document reports on a materials development project created for volunteer tutors in the English-In-Action (EIA) program of the Bechtel International Center at Stanford University. EIA provides foreign students, visiting scholars, and their spouses with the opportunity to improve their English language skills in an informal, conversational…

  8. A Model of Objective Weighting for EIA.

    ERIC Educational Resources Information Center

    Ying, Long Gen; Liu, You Ci

    1995-01-01

    In the research of environmental impact assessment (EIA), the problem of weight distribution for a set of parameters has not yet been properly solved. Presents an approach of objective weighting by using a procedure of Pij principal component-factor analysis (Pij PCFA), which suits specifically those parameters measured directly by physical…

  9. South Carolina's Education Improvement Act: Is It Working?

    ERIC Educational Resources Information Center

    Richardson, Mike; And Others

    South Carolina's response to the excellence literature of the early 1980s is called the Education Improvement Act (EIA). This act increased high school graduation requirements, required basic skills testing and standardized observation of teacher candidates, and mandated extensive competency testing and remediation of students. The EIA, like most…

  10. Imbibing Wisdom of Environmental Impact Assessment.

    ERIC Educational Resources Information Center

    Thomas, Ian

    1992-01-01

    Describes a learning module for Environmental Impact Assessment (EIA) and the relationship between EIA objectives and those of the module. Discusses constraints influencing the form of the subject and the range of possible training techniques. Presents details of the module's structure and comments on its approach. (Contains 16 references.) (MDH)

  11. Update on Exercise-Induced Asthma. A Report of the Olympic Exercise Asthma Summit Conference.

    ERIC Educational Resources Information Center

    Storms, William W.; Joyner, David M.

    1997-01-01

    Summarizes results from the Olympic Exercise Asthma Summit Conference, offering the latest on identifying and managing exercise-induced asthma (EIA). Concludes that effective pharmacologic and nonpharmacologic treatment is available, but EIA is underrecognized and underdiagnosed. Physicians should look for it in all patients, including school…

  12. Changes in Natural Gas Monthly Consumption Data Collection and the Short-Term Energy Outlook

    EIA Publications

    2010-01-01

    Beginning with the December 2010 issue of the Short-Term Energy Outlook (STEO), the Energy Information Administration (EIA) will present natural gas consumption forecasts for the residential and commercial sectors that are consistent with recent changes to the Form EIA-857 monthly natural gas survey.

  13. 76 FR 49757 - Agency Information Collection Activities: Proposed Collection; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-11

    .... SUMMARY: The EIA is soliciting comments on the proposed new Form EIA- 111, ``Quarterly Electricity Imports and Exports Report.'' This new form would supersede the existing Form OE-781R, ``Monthly Electricity... Power Monthly, and Monthly Energy Review. The existing survey of electricity imports and exports (OE...

  14. 77 FR 4026 - Proposed Agency Information Collection

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-26

    ... supersede the existing Form OE-781R, ``Monthly Electricity Imports and Exports Report''. The Form OE-781R is...) Annual Estimated Reporting and Recordkeeping Cost Burden. 1. New. 2. Form EIA-111, Quarterly Electricity Imports and Exports Report. 3. Three-year approval. 4. Form EIA-111 collects U.S. electricity import and...

  15. 77 FR 34368 - Agency Information Collection Extension

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-11

    ... Gasoline Blending Components, All Other --Kerosene-Type Jet Fuel --Distillate Fuel Oil by Sulfur Category (15 ppm sulfur and under, Greater than 15 ppm to 500 ppm sulfur (inclusive), and Greater than 500 ppm sulfur) Eliminating Form EIA-801 and the proposed changes to Form EIA-805 will make weekly bulk terminal...

  16. 76 FR 70123 - Agency Information Collection Activities: Proposed Collection; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-10

    ... Natural Gas Production Report. DATES: Comments must be filed by January 9, 2012. If you anticipate... the United States and the requirement for accurate and timely natural gas production information... disseminated through the EIA Natural Gas Monthly, Monthly Natural Gas Gross Production Report, and EIA Natural...

  17. Analysis of Senate Amendment 2028, the Climate Stewardship Act of 2003

    EIA Publications

    2004-01-01

    On May 11, 2004, Senator Landrieu asked the Energy Information Administration (EIA) to evaluate SA 2028. This paper responds to that request, relying on the modeling methodology, data sources, and assumptions used to analyze the original bill, as extensively documented in EIA's June 2003 report.

  18. GRAPHICAL REPRESENTATIONS OF 1991 STEAM-ELECTRIC POWER PLANT OPERATION AND AIR EMISSIONS DATA

    EPA Science Inventory

    The report provides graphical representations of data derived from the U.S. Department of Energy's (DOE's) Energy Information Administration, s Form EIA-767 (Steam Electric Plant Operation and Design Report). or more than 10 years, EIA has collected monthly boiler level data from...

  19. Towards SEA for the developing nations of Asia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Briffett, Clive; Obbard, Jeffrey Philip; Mackee, Jamie

    2003-03-01

    In the developing and transitional countries of Asia, environmental impact assessment (EIA) has been widely practiced as a planning tool that identifies the potential impacts associated with developments and determines their level of significance and the need for mitigating measures. Not withstanding its extensive use in many Asian countries, certain limitations are now being increasingly recognised with regard to achieving sustainable development within the planning process. It is also noted that the natural environment in Asia has continued to be severely degraded despite the adoption of EIA. This research project was undertaken at the National University of Singapore to reviewmore » the status on the implementation of EIA procedures and to investigate the status and potential of strategic environmental assessment (SEA) in Asia. The research project generally investigated the existing physical attributes of six countries including Hong Kong and Singapore, Malaysia and the Philippines, Sri Lanka and Vietnam and discussed their prevailing environmental conditions. It more specifically reviewed policymaking and environmental planning, environmental legislation and the practice and procedures of environmental impact assessment. It also evaluated environmental assessment education and training activities. In some cases such as Hong Kong, an opportunity to analyse actual SEA practice was included. In other cases, the potential for possible take up of formal SEA was assessed. A comparative review assesses the degree to which EIA and SEA procedures have been utilized, considers how the use of SEA could overcome the deficiencies of the EIA project-based system and includes aspects of meeting sustainability criteria. Results show that the use and application of EIA is relatively strong across all countries with the possible exception of Singapore which relies more heavily on its planning and control system to address potential environmental impacts arising from development projects. Despite this, EIAs have been undertaken in every country due to aid and bank lending agencies requiring them and multinational companies and many local NGOs completing voluntary EIAs. Even though the mandatory introduction of EIA into some countries is fairly recent such as Hong Kong (1999) and Vietnam (1994), efforts to conduct such investigations may have started many years before. The country reviews highlight many common problems and adverse influences that give rise to inadequate EIA practice, and in some cases, recommendations for improvement are proposed. The potential for SEA is assessed on the basis of its present usage which is generally small except for Hong Kong and the environmental strategic decision-making that is being conducted in policy, plan and programme formulations. While the more comprehensive and well-refined westernized model of SEA is generally weakly implemented at present, there is evidence to suggest that Agenda 21, along with other international treaties such as the Biodiversity Charter and the Ramsar Convention, has motivated certain sustainability initiatives that are resulting in increased environmental considerations at a strategic level. In some cases, these may be reflected in National Plan policymaking or in the sector and area-based activities of various ministries and departments. It is concluded that SEA potential is generally strong in those countries with smaller centralized bureaucracies but that its successful implementation will be highly dependent on changing the mind-sets and motivations of top personnel at ministerial level.« less

  20. 3D multiplexed immunoplasmonics microscopy

    NASA Astrophysics Data System (ADS)

    Bergeron, Éric; Patskovsky, Sergiy; Rioux, David; Meunier, Michel

    2016-07-01

    Selective labelling, identification and spatial distribution of cell surface biomarkers can provide important clinical information, such as distinction between healthy and diseased cells, evolution of a disease and selection of the optimal patient-specific treatment. Immunofluorescence is the gold standard for efficient detection of biomarkers expressed by cells. However, antibodies (Abs) conjugated to fluorescent dyes remain limited by their photobleaching, high sensitivity to the environment, low light intensity, and wide absorption and emission spectra. Immunoplasmonics is a novel microscopy method based on the visualization of Abs-functionalized plasmonic nanoparticles (fNPs) targeting cell surface biomarkers. Tunable fNPs should provide higher multiplexing capacity than immunofluorescence since NPs are photostable over time, strongly scatter light at their plasmon peak wavelengths and can be easily functionalized. In this article, we experimentally demonstrate accurate multiplexed detection based on the immunoplasmonics approach. First, we achieve the selective labelling of three targeted cell surface biomarkers (cluster of differentiation 44 (CD44), epidermal growth factor receptor (EGFR) and voltage-gated K+ channel subunit KV1.1) on human cancer CD44+ EGFR+ KV1.1+ MDA-MB-231 cells and reference CD44- EGFR- KV1.1+ 661W cells. The labelling efficiency with three stable specific immunoplasmonics labels (functionalized silver nanospheres (CD44-AgNSs), gold (Au) NSs (EGFR-AuNSs) and Au nanorods (KV1.1-AuNRs)) detected by reflected light microscopy (RLM) is similar to the one with immunofluorescence. Second, we introduce an improved method for 3D localization and spectral identification of fNPs based on fast z-scanning by RLM with three spectral filters corresponding to the plasmon peak wavelengths of the immunoplasmonics labels in the cellular environment (500 nm for 80 nm AgNSs, 580 nm for 100 nm AuNSs and 700 nm for 40 nm × 92 nm AuNRs). Third, the developed technology is simple and compatible with standard epi-fluorescence microscopes used in biological and clinical laboratories. Thus, 3D multiplexed immunoplasmonics microscopy is ready for clinical applications as a cost-efficient alternative to immunofluorescence.Selective labelling, identification and spatial distribution of cell surface biomarkers can provide important clinical information, such as distinction between healthy and diseased cells, evolution of a disease and selection of the optimal patient-specific treatment. Immunofluorescence is the gold standard for efficient detection of biomarkers expressed by cells. However, antibodies (Abs) conjugated to fluorescent dyes remain limited by their photobleaching, high sensitivity to the environment, low light intensity, and wide absorption and emission spectra. Immunoplasmonics is a novel microscopy method based on the visualization of Abs-functionalized plasmonic nanoparticles (fNPs) targeting cell surface biomarkers. Tunable fNPs should provide higher multiplexing capacity than immunofluorescence since NPs are photostable over time, strongly scatter light at their plasmon peak wavelengths and can be easily functionalized. In this article, we experimentally demonstrate accurate multiplexed detection based on the immunoplasmonics approach. First, we achieve the selective labelling of three targeted cell surface biomarkers (cluster of differentiation 44 (CD44), epidermal growth factor receptor (EGFR) and voltage-gated K+ channel subunit KV1.1) on human cancer CD44+ EGFR+ KV1.1+ MDA-MB-231 cells and reference CD44- EGFR- KV1.1+ 661W cells. The labelling efficiency with three stable specific immunoplasmonics labels (functionalized silver nanospheres (CD44-AgNSs), gold (Au) NSs (EGFR-AuNSs) and Au nanorods (KV1.1-AuNRs)) detected by reflected light microscopy (RLM) is similar to the one with immunofluorescence. Second, we introduce an improved method for 3D localization and spectral identification of fNPs based on fast z-scanning by RLM with three spectral filters corresponding to the plasmon peak wavelengths of the immunoplasmonics labels in the cellular environment (500 nm for 80 nm AgNSs, 580 nm for 100 nm AuNSs and 700 nm for 40 nm × 92 nm AuNRs). Third, the developed technology is simple and compatible with standard epi-fluorescence microscopes used in biological and clinical laboratories. Thus, 3D multiplexed immunoplasmonics microscopy is ready for clinical applications as a cost-efficient alternative to immunofluorescence. Electronic supplementary information (ESI) available: Characterization of functionalized nanoparticles by UV-visible-NIR spectroscopy, standard dark field microscopy and reflected light microscopy. Immunofluorescence of cells. See DOI: 10.1039/c6nr01257d

  1. 40 CFR 94.909 - Export exemptions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Export exemptions. 94.909 Section 94... Export exemptions. (a) A new engine intended solely for export, and so labeled or tagged on the outside... of export under paragraph (a) of this section, that such exemption is void ab initio with respect to...

  2. A Simple Model System to Demonstrate Antibody Structure and Functions.

    ERIC Educational Resources Information Center

    O'Kennedy, Richard

    1991-01-01

    A model that can be used to show the arrangement of light and heavy chains, disulfide linkages, domains, and subclass variations in antibodies is given. It can be constructed and modified to illustrate Fab, F(ab')2, and Fc fragments, single domain and bifunctional antibodies, and labeling of antibodies. (Author)

  3. A novel cancer-targeting transporter with integrin αvβ3 monoclonal antibody functionalized single-walled carbon nanotubes

    NASA Astrophysics Data System (ADS)

    Ou, Zhongmin; Wu, Baoyan; Xing, Da

    2009-08-01

    The pursuit of efficient and highly targeting-selective transporters is an active topic in cancer-targeting therapy. In this study, a novel cancer-targeting transporter with integrin αvβ3 monoclonal antibody functionalized single-walled carbon nanotubes (SWCNTs) was developed to investigate cancer cell targeting in vitro. SWCNTs were first modified by phospholipid-bearing polyethylene glycol (PL-PEG). PL-PEG functionalized SWCNTs were then conjugated with fluorescein isothiocyanate (FITC) labeled integrin αvβ3 monoclonal antibody to construct SWCNT-integrin αvβ3 monoclonal antibody system (denoted as SWCNT-PEG-mAb). In vitro study revealed that the system had a high efficiency in cancer cell targeting in integrin αvβ3 positive U87MG cells. Moreover, the SWCNT-PEG-mAb is stable in physiological media, and can be readily transported into U87MG cells via integrin αvβ3-mediated endocytosis in cell. In summary, the integrin αvβ3 monoclonal antibody labeled SWCNT is a potential carrier-candidate for cancer-imaging and drug-delivering in cancer-targeting therapy.

  4. Specific and nonspecific immunoassays to detect HAMA after administration of indium-111-labeled OV-TL 3 F(ab')2 monoclonal antibody to patients with ovarian cancer.

    PubMed

    Massuger, L F; Thomas, C M; Segers, M F; Corstens, F H; Verheijen, R H; Kenemans, P; Poels, L G

    1992-11-01

    The development of human anti-mouse antibodies (HAMA) may cause problems in radioimmunotargeting studies, but may also improve survival of patients. To identify the presence of HAMA in blood samples from patients intravenously injected with 1 mg of 111In-labeled OV-TL3-F(ab')2, we developed three specific OV-TL 3-based HAMA assays and tested these along with two commercially available nonspecific HAMA assays (Sorin and Immunomedics). The specific assays were positive for HAMA with 10 postinjection serum samples from 7 patients. Eight of the 10 samples were also HAMA positive with one or both nonspecific HAMA assays. Conflicting results were observed with half the number of samples. The two nonspecific assays also reacted positively with another 11 serum samples from 5 patients including their preinjection samples. Despite some contradictory results, the nonspecific HAMA assays identify both pre-existent and Mab-induced HAMA, whereas the specific OV-TL3-based HAMA assays identify specific immune-responses occurring after the OV-TL 3 injection.

  5. [Diagnostic advantages of the test system "DS-EIA-HBsAg-0.01" for detection of HBV surface antigen].

    PubMed

    Egorova, N I; Pyrenkova, I Iu; Igolkina, S N; Sharipova, I N; Puzyrev, V F; Obriadina, A P; Burkov, A N; Kornienko, N V; Fields, H A; Korovkin, A S; Shalunova, N V; Bektemirov, T A; Kuznetsov, K V; Koshcheeva, N A; Ulanova, T I

    2009-01-01

    The new highly sensitive test system "DS-EIA-HBsAg-0.01" (Priority Certificate No. 2006129019 of August 10, 2006) in detecting hepatitis B surface antigen (HBsAg) was assessed. The sensitivity of the test was estimated using the federal standards sample HBsAg 42-28-311-06, panels' samples Boston Biomedica Inc. (West Bridgewater, Mass, USA) and ZeptoMetrix Corp. (Buffalo, NY, USA). The findings have indicated that "DS-EIA-HBsAg-0.01" is equally effective in detecting different subtypes of HBsAg during a seroconversion period earlier than alternative assays. Along with its high analytical and diagnostic sensitivity, the system shows a high diagnostic specificity.

  6. Antigen based detection of cystic echinococcosis in buffaloes using ELISA and Dot-EIA.

    PubMed

    Sangaran, A; Bino Sundar, S T; Latha, Bhaskaran Ravi

    2017-03-01

    Cystic echinococcosis is caused by the larval stage of the dog tapeworm, Echinococcus granulosus . The disease is recognized as one of the world's major zoonoses affecting human beings and domestic animals apart from its economic and public health importance. Development of the cysts in the intermediate host such as buffaloes occurs in the lungs, liver and other organs. In this study, detection of circulating antigen in the diagnosis of cystic echinococcosis in buffaloes was done using enzyme linked immunosorbent assay and Dot-Enzyme immunoassay (Dot-EIA). The sensitivity and specificity were determined as 89 and 92 % respectively, whereas those of Dot-EIA were determined as 94 and 96 %.

  7. Improving the Quality and Scope of EIA Data

    EIA Publications

    2011-01-01

    Section 805(a) of the Energy Independence and Security Act of 2007 (EISA), Public Law 110-1401 requires the U.S. Energy Information Administration (EIA) to establish a five-year plan to enhance the quality and scope of its data collection necessary to ensure that the scope, accuracy, and timeliness of the information needed for efficient functioning of energy markets and related financial operations. This report is in response to section 805(b) of EISA which calls on EIA to submit to Congress the plan established under subsection (a), including a description of any improvements needed to enhance the ability of the Administrator to collect and process energy information in a manner consistent with the needs of energy markets.

  8. Tunable electromagnetically induced absorption based on graphene

    NASA Astrophysics Data System (ADS)

    Cao, Maoyong; Wang, Tongling; Zhang, Huiyun; Zhang, Yuping

    2018-04-01

    In this paper, an electronically induced absorption (EIA) structure based on graphene at the infrared frequency is proposed. A pair of nanorods is coupled to a ring resonator, resulting in electronically induced transparency (EIT), and then, Babinet's principle is applied to transform the EIT structure into an EIA structure. Based on the bright and dark modes of the coupling schemes, the adjustment of the coupling strength between the dark and bright modes can be achieved by changing the asymmetry degree. In addition, the transparency window and the absorption peak can be tuned by changing the Fermi energy of graphene. This graphene-based EIA structure can develop the path in narrow-band filtering and, absorptive switching in the future.

  9. Electromagnetically Induced Transparency Experiments for the Advanced Undergraduate Laboratory: Suppression of Polarization Impurity and Stray Magnetic Fields

    NASA Astrophysics Data System (ADS)

    Campbell, Kaleb; Jackson, Richard; van Vleet, Matthew; Kuhnash, Kodi; Worth, Bradley; Day, Amanda; Bali, Samir

    2014-05-01

    We investigate electromagnetically induced transparency (EIT) and electromagnetically induced absorption (EIA) in rubidium vapor using a single laser beam and a scanning magnetic field co-aligned with the laser propagation direction. We show that polarization impurity, stray magnetic fields and imperfect optical alignments cause broadening of the EIT/EIA signal and other spurious effects. We describe a systematic approach to minimizing these undesired effects, which produces EIT/EIA signals nearly two orders of magnitude narrower than the natural linewidth. We gratefully acknowledge funding from the American Chemical Society Petroleum Research Fund and Miami University. We also acknowledge the Miami University Instrumentation Laboratory for their invaluable contributions.

  10. An electrochemical aptasensor for multiplex antibiotics detection based on metal ions doped nanoscale MOFs as signal tracers and RecJf exonuclease-assisted targets recycling amplification.

    PubMed

    Chen, Meng; Gan, Ning; Zhou, You; Li, Tianhua; Xu, Qing; Cao, Yuting; Chen, Yinji

    2016-12-01

    An ultrasensitive electrochemical aptasensor for simultaneous detection of oxytetracycline (OTC) and kanamycin (KAN) has been developed based on metal ions doped metal organic frame materials (MOFs) as signal tracers and RecJ f exonuclease-catalyzed targets recycling amplification. The aptasensor consists of capture beads (the anti-single-stranded DNA Antibody, as anti-ssDNA Ab, labeled on Dynabeads) and nanoscale MOF (NMOF) based signal tracers (simplified as Apts-MNM, the NMOF labeled with metal ions and the aptamers). Particularly, the MOF (UiO-66-NH 2 ), with large internal surface areas, ultrahigh porosity and abundant amine groups in the pores, was employed as substrates to carry plenty of metal ions (Pb 2+ or Cd 2+ ) and label aptamers of OTC or KAN. Thus, the aptasensor is formed by the specific recognition between anti-ssDNA Ab and aptamers. In the presence of targets (OTC and KAN), aptamers prefer to form targets-Apts-MNM complexes in lieu of anti-ssDNA Ab-aptamer complexes, which results in the dissociation of Apts-MNM from capture beads. With the employment of RecJ f exonuclease, targets-Apts-MNM in supernatant was digested into mononucleotides and liberated the target, which can further participate in the next reaction cycling to produce more signal tracers. After magnetic separation, the enhanced square wave voltammetry (SWV) signals were produced from signal tracers. The aptasensor exhibited a linear correlation in the range from 0.5pM to 50nM, with detection limits of 0.18pM and 0.15pM (S/N=3) toward OTC and KAN respectively. This strategy provides specificity and sensitive approach for multiplex antibiotics detection and has promising applications in food analysis. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Ultrasensitive electrochemical immunoassay for surface array protein, a Bacillus anthracis biomarker using Au-Pd nanocrystals loaded on boron-nitride nanosheets as catalytic labels.

    PubMed

    Sharma, Mukesh Kumar; Narayanan, J; Pardasani, Deepak; Srivastava, Divesh N; Upadhyay, Sanjay; Goel, Ajay Kumar

    2016-06-15

    Bacillus anthracis, the causative agent of anthrax, is a well known bioterrorism agent. The determination of surface array protein (Sap), a unique biomarker for B. anthracis can offer an opportunity for specific detection of B. anthracis in culture broth. In this study, we designed a new catalytic bionanolabel and fabricated a novel electrochemical immunosensor for ultrasensitive detection of B. anthracis Sap antigen. Bimetallic gold-palladium nanoparticles were in-situ grown on poly (diallyldimethylammonium chloride) functionalized boron nitride nanosheets (Au-Pd NPs@BNNSs) and conjugated with the mouse anti-B. anthracis Sap antibodies (Ab2); named Au-Pd NPs@BNNSs/Ab2. The resulting Au-Pd NPs@BNNSs/Ab2 bionanolabel demonstrated high catalytic activity towards reduction of 4-nitrophenol. The sensitivity of the electrochemical immunosensor along with redox cycling of 4-aminophenol to 4-quinoneimine was improved to a great extent. Under optimal conditions, the proposed immunosensor exhibited a wide working range from 5 pg/mL to 100 ng/mL with a minimum detection limit of 1 pg/mL B. anthracis Sap antigen. The practical applicability of the immunosensor was demonstrated by specific detection of Sap secreted by the B. anthracis in culture broth just after 1h of growth. These labels open a new direction for the ultrasensitive detection of different biological warfare agents and their markers in different matrices. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Profile of Instrumentation Laboratory's HemosIL® AcuStar HIT-Ab(PF4-H) assay for diagnosis of heparin-induced thrombocytopenia.

    PubMed

    Nagler, Michael; Cuker, Adam

    2017-05-01

    Immunoassays play an essential role in the diagnosis of heparin-induced thrombocytopenia (HIT). The objective of this article is to review HemosIL® AcuStar HIT-Ab(PF4-H) (Instrumentation Laboratory, Bedford, MA, USA), a new chemiluminescent immunoassay for HIT. Areas covered: The authors searched the published literature for evaluation studies of HemosIL® AcuStar HIT-Ab(PF4-H) and sought information from the manufacturer. In this paper, the authors discuss the analytical principle and technical aspects of the assay; describe its diagnostic performance in validation studies; report on its reproducibility, cost-effectiveness, and regulatory status; and discuss the implications of the assay on clinical practice and means of integrating it in diagnostic pathways. HemosIL® AcuStar HIT-Ab(PF4-H) is compared with other rapid assays and widely used enzyme-linked immunoassays for the diagnosis of HIT. Expert commentary: HemosIL® AcuStar HIT-Ab(PF4-H) is automatable, can be performed 24 h per day, offers a rapid turnaround time, and appears to have favorable diagnostic accuracy, particularly at thresholds above that listed in the label. These advantages could lead to improved patient outcomes through rapid provision of results at the point of care, enhancing the accuracy of initial diagnosis.

  13. Redox states of Desulfovibrio vulgaris DsrC, a key protein in dissimilatory sulfite reduction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Venceslau, Sofia S.; Cort, John R.; Baker, Erin S.

    2013-11-29

    Highlights: •DsrC is known to interact with the dissimilatory sulfite reductase enzyme (DsrAB). •We show that, however, most cellular DsrC is not associated with DsrAB. •A gel-shift assay was developed that allows monitoring of the DsrC redox state. •The DsrC intramolecularly oxidized state could only be produced by arginine treatment. -- Abstract: Dissimilatory reduction of sulfite is carried out by the siroheme enzyme DsrAB, with the involvement of the protein DsrC, which has two conserved redox-active cysteines. DsrC was initially believed to be a third subunit of DsrAB. Here, we report a study of the distribution of DsrC in cellmore » extracts to show that, in the model sulfate reducer Desulfovibrio vulgaris, the majority of DsrC is not associated with DsrAB and is thus free to interact with other proteins. In addition, we developed a cysteine-labelling gel-shift assay to monitor the DsrC redox state and behaviour, and procedures to produce the different redox forms. The oxidized state of DsrC with an intramolecular disulfide bond, which is proposed to be a key metabolic intermediate, could be successfully produced for the first time by treatment with arginine.« less

  14. 75 FR 19379 - Agency Information Collection Activities: Proposed Collection; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-14

    ..., ``Annual Survey of Alternative Fueled Vehicles.'' DATES: Comments must be filed by June 14, 2010. If you.... Form EIA-886, ``Annual Survey of Alternative Fueled Vehicles'' is an annual survey that collects... users of AFVs. The objective of the EIA-886 survey are to: (1) Comply with section 503 of the Energy...

  15. 77 FR 45593 - Proposed Agency Information Collection

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-01

    ... Report of the Origin of Natural Gas Liquids, and Form EIA-816, Monthly Natural Gas Liquids Report, as....: NEW; (2) Information Collection Request Title: Monthly Gas Processing and Liquids Report; (3) Type of... collection form that is a combination of the Form EIA-64A, Annual Report of the Origin of Natural Gas Liquids...

  16. 76 FR 11444 - Agency Information Collection Activities: Proposed Collection; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-02

    ... Natural Gas Data Collection Program Package. The surveys covered by this request include: Form EIA-176... burden for the surveys included in the Natural Gas Data Collection Program Package is shown below as an... help the EIA prepare data requests that maximize the utility of the information collected and assess...

  17. 76 FR 55059 - Agency Information Collection Activities: Submission for OMB Review; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-06

    ... the Natural Gas Data Collection Program Package is to collect basic and detailed data to meet the EIA... Natural Gas Data Collection Program Package surveys are among those that are required to address the... Request. SUMMARY: The EIA has submitted the Energy Information Administration's Natural Gas Data...

  18. Public Participation Planning of Environmental Impact Assessment (EIA) and Regulations: Analysis of Inconsistency for Some Cases in Indonesia

    NASA Astrophysics Data System (ADS)

    Hindrayani, Aniek; Purwanto

    2018-02-01

    The failure in community involvement during the environmental documents planning may result in the failure of the planned project implementation. This study aims to determine the gap between practices and regulations that apply to the process of community involvement in the environmental documents planning, and find out inconsistency of implementation on each stakeholder in the planning of the Environmental Impact Assessment (EIA) and the environmental permit. The method used was qualitative through interview and literature study which is analyzed using triangulation model and presented in the form of concept map. The results of the study indicate that 1) the determination of community representatives based on the criteria of the impacted communities is not clearly described, 3) suggestions, opinions, and responses to the environmental impact management are not well implemented by the project proponent, 3) implementation of the environmental management of other licensed activities affecting the behavior (4) stakeholders (project proponent, EIA consultants, and EIA appraisal committee) do not play their role as mandated in applicable legislation.

  19. Cultural influences on implementing environmental impact assessment: Insights from Thailand, Indonesia, and Malaysia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boyle, J.

    In Thailand, Indonesia, and Malaysia, political and business support for environmental impact assessment (EIA) is low, and environmental agencies are virtually powerless compared with economic development agencies. Whereas technical factors contribute to the consequent ineffectiveness of EIA, cultural factors provide complementary explanations. A reliance on paternalistic authority, hierarchy, and status as principles of social organization; a dependence on patron-client relationships for ensuring loyalty and advancement among political, bureaucratic, and private-sector actors; and a strong desire to avoid conflict and maintain face; all of these factors reinforce the power of political and business elites and circumscribe that of individuals and communities.more » They also result in government bureaucracies where low-status environmental agencies have little power or authority and the interagency cooperation needed for effective EIA is lacking. The article demonstrates that it is vital to consider cultural as well as technical factors when examining the difficulties of implementing policies or programs like EIA, which are invented in the West and transferred to another culture with very different social and political heritages and practices.« less

  20. Refocusing-range and image-quality enhanced optical reconstruction of 3-D objects from integral images using a principal periodic δ-function array

    NASA Astrophysics Data System (ADS)

    Ai, Lingyu; Kim, Eun-Soo

    2018-03-01

    We propose a method for refocusing-range and image-quality enhanced optical reconstruction of three-dimensional (3-D) objects from integral images only by using a 3 × 3 periodic δ-function array (PDFA), which is called a principal PDFA (P-PDFA). By directly convolving the elemental image array (EIA) captured from 3-D objects with the P-PDFAs whose spatial periods correspond to each object's depth, a set of spatially-filtered EIAs (SF-EIAs) are extracted, and from which 3-D objects can be reconstructed to be refocused on their real depth. convolutional operations are performed directly on each of the minimum 3 × 3 EIs of the picked-up EIA, the capturing and refocused-depth ranges of 3-D objects can be greatly enhanced, as well as 3-D objects much improved in image quality can be reconstructed without any preprocessing operations. Through ray-optical analysis and optical experiments with actual 3-D objects, the feasibility of the proposed method has been confirmed.

Top