  1. Managing lead-based paint abatement wastes

    SciTech Connect

    Steele, N.L.C.

    1994-12-31

    Renovation, remodeling, demolition, and surface preparation for painting, in addition to specified lead abatement, are all activities that have the potential to produce hazardous wastes if a property was painted with lead-based paint. Lead-based paint was used on residential structures until 1978, when most residential uses were banned by the Consumer Products Safety Council. Prior to the 1950s, paints for residential uses may have contained up to 50% lead by weight. Today, commercial and military paints may still contain lead and can be used on non-residential structures. The lead content of residential paints is limited to 0.06% lead (by weight) in the dried film. This paper provides an overview of some of the information needed to properly manage lead-based paint abatement wastes. The issues covered in this paper include waste classification, generator status, treatment, and land disposal restrictions. The author assumes that the reader is familiar with the provision of the Health and Safety Code and the California Code of Regulations that pertain to generation and management of hazardous wastes. Citations provided herein do not constitute an exhaustive list of all the regulations with which a generator of hazardous waste must comply.

  2. Health and environmental outcomes of traditional and modified practices for abatement of residential lead-based paint

    SciTech Connect

    Farfel, M.R.; Chisolm, J.J. Jr. )

    1990-10-01

    We evaluated traditional and modified practices for abating lead-based paint in homes of children with blood-lead concentrations (PbB) greater than 1.4 mumol/L (greater than 29 micrograms/dl). Traditional abatement resulted in acute increases in: (1) lead contaminated house dust (generally 3 to 6-fold over pre-abatement levels, but at abated sites typically 10 to 100-fold); and (2) the PbBs of nearly half of the occupant children. Modified practices represented modest short-term improvement compared to traditional practices but were also inadequate. By six months, it was clear that neither form of abatement resulted in long-term reductions of PbB or house dust lead levels, leaving children at continued risk of excessive exposure to lead and permanent adverse neurobehavioral effects. Windows were found to be high sources of lead contaminated house dust. Recommendations are made for improved abatement practices including more complete abatement of window units and more effective clean-up to remove lead-bearing dust. Thirteen million US children live in lead-painted dwellings. Research is needed to identify abatement strategies that will be practical and well suited to the current understanding of low-level lead toxicity.

  3. Efficiency of final cleaning for lead-based paint abatement in indoor environments.

    PubMed

    Grinshpun, Sergey A; Choe, Kyoo T; Trunov, Mikhaylo; Willeke, Klaus; Menrath, William; Friedman, Warren

    2002-03-01

    The effectiveness of procedures used for the final indoor cleaning after active lead-based paint abatement were evaluated in a 830 ft3 test chamber. Dry and wet scraping and dry machine sanding were applied to wooden doors obtained from lead-hazard control sites. The airborne particle concentration and size distribution were monitored using a real-time particle size spectrometer. Particulates were also collected on filters and analyzed for total dust and lead. The resulting airborne lead mass was determined for each cleaning procedure, and the potential floor lead loading resulting from the dust settling was calculated. Wipe samples were collected to measure the actual floor lead loading. The effectiveness of final cleaning was evaluated first for dry abatement methods. Various cleaning work practices were tested by applying wet and dry debris sweeping as well as no sweeping in combinations with wet and dry removal of plastic sheeting. Considerable resuspension of leaded particles was detected during dry sweeping: the airborne lead mass increase ranged between 65 and 220 percent. However, this increase did not exceed 22 percent when wet sweeping was applied. Minimal or no resuspension was found when the plastic was folded with leaded debris inside (no sweeping was performed prior to the sheeting removal). During folding activity, the "clean" (uncovered) floor surface may be significantly contaminated with leaded dust from workers' shoes and cleaning tools. The first HEPA vacuuming resulted in a 15- to 20-fold decrease of the airborne lead mass; however, it was not sufficient to reduce the floor lead loading to the U.S. Department of Housing and Urban Development (HUD) clearance level of 40 microg/ft2, as determined by wipe sampling. Wet mopping following the first HEPA vacuuming was proven to be effective to reduce the lead loading significantly below 40 microg/ft2. The second HEPA vacuuming resulted in further reduction of the airborne lead mass concentration. The

  4. COST ESTIMATES OF USING THREE LEAD-BASED PAINT ABATEMENT TECHNOLOGIES ON RESIDENTIAL HOUSING

    EPA Science Inventory

    Elevated blood lead levels in children of the US due to exposure to flaking lead-based paint continues to be an important health concern. Approximately 57M housing units, which represent 75% of all privately owned and occupied housing built before 1980 in the US are contaminated ...

  5. Lead-based paint assessment

    SciTech Connect

    Lorie, C.; Cowdery, J.W.

    1994-12-31

    In 1977, The US consumer product safety commission banned the use of lead-based paint (LBP) in all industries, except the maritime industry which still has certain privileged uses. Unfortunately for property and building owners, the ban did not come soon enough. In response to this heightened awareness, several environmental market sectors addressing the issues have emerged. These include: residential; soil; commercial; water; and structures. The first and most important step in addressing the concerns posed by the existence of lead based contamination is to quantify the amount of lead-based product, to determine the location of the lead based product and the extent, if any, of lead based contamination, and to make recommendations for the remediation or abatement of the lead product and resultant contamination. In narrowing the focus of these issues, this paper discusses lead-based paint assessment; preparing and organizing the assessment, the regulatory considerations, assessment methodology, and presentation of results.

  6. Residential lead-based-paint hazard remediation and soil lead abatement: their impact among children with mildly elevated blood lead levels.

    PubMed Central

    Aschengrau, A; Beiser, A; Bellinger, D; Copenhafer, D; Weitzman, M

    1997-01-01

    OBJECTIVES: This prospective study describes the impact of residential lead-based-paint hazard remediations on children with mildly elevated blood lead levels. METHODS: Changes in blood lead levels were observed following paint hazard remediation alone and in combination with soil abatement. RESULTS: After adjustment for the confounding variables paint hazard remediation alone was associated with a blood lead increase of 6.5 micrograms/dL (P = 0.5), and paint hazard remediation combined with soil abatement was associated with an increase of 0.9 microgram/dL (P = 36). CONCLUSIONS: Lead-based-paint hazard remediation as performed in this study, is not an effective secondary prevention strategy among children with mildly elevated blood lead levels. PMID:9357358

  7. 24 CFR 200.800 - Lead-based paint.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 2 2010-04-01 2010-04-01 false Lead-based paint. 200.800 Section... DEVELOPMENT GENERAL INTRODUCTION TO FHA PROGRAMS Lead-Based Paint Poisoning Prevention § 200.800 Lead-based paint. The Lead-Based Paint Poisoning Prevention Act (42 U.S.C. 4821-4846), the Residential...

  8. 24 CFR 598.408 - Lead-based paint requirements.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 24 Housing and Urban Development 3 2014-04-01 2013-04-01 true Lead-based paint requirements. 598... DESIGNATIONS Post-Designation Requirements § 598.408 Lead-based paint requirements. The Lead-Based Paint Poisoning Prevention Act (42 U.S.C. 4821-4846), the Residential Lead-Based Paint Hazard Reduction Act...

  9. 24 CFR 200.800 - Lead-based paint.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 24 Housing and Urban Development 2 2011-04-01 2011-04-01 false Lead-based paint. 200.800 Section... DEVELOPMENT GENERAL INTRODUCTION TO FHA PROGRAMS Lead-Based Paint Poisoning Prevention § 200.800 Lead-based paint. The Lead-Based Paint Poisoning Prevention Act (42 U.S.C. 4821-4846), the Residential...

  10. 24 CFR 598.408 - Lead-based paint requirements.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 24 Housing and Urban Development 3 2012-04-01 2012-04-01 false Lead-based paint requirements. 598... DESIGNATIONS Post-Designation Requirements § 598.408 Lead-based paint requirements. The Lead-Based Paint Poisoning Prevention Act (42 U.S.C. 4821-4846), the Residential Lead-Based Paint Hazard Reduction Act...

  11. 24 CFR 598.408 - Lead-based paint requirements.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 3 2010-04-01 2010-04-01 false Lead-based paint requirements. 598... DESIGNATIONS Post-Designation Requirements § 598.408 Lead-based paint requirements. The Lead-Based Paint Poisoning Prevention Act (42 U.S.C. 4821-4846), the Residential Lead-Based Paint Hazard Reduction Act...

  12. 24 CFR 200.800 - Lead-based paint.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 24 Housing and Urban Development 2 2013-04-01 2013-04-01 false Lead-based paint. 200.800 Section... DEVELOPMENT GENERAL INTRODUCTION TO FHA PROGRAMS Lead-Based Paint Poisoning Prevention § 200.800 Lead-based paint. The Lead-Based Paint Poisoning Prevention Act (42 U.S.C. 4821-4846), the Residential...

  13. 24 CFR 598.408 - Lead-based paint requirements.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 24 Housing and Urban Development 3 2013-04-01 2013-04-01 false Lead-based paint requirements. 598... DESIGNATIONS Post-Designation Requirements § 598.408 Lead-based paint requirements. The Lead-Based Paint Poisoning Prevention Act (42 U.S.C. 4821-4846), the Residential Lead-Based Paint Hazard Reduction Act...

  14. 24 CFR 200.800 - Lead-based paint.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 24 Housing and Urban Development 2 2014-04-01 2014-04-01 false Lead-based paint. 200.800 Section... DEVELOPMENT GENERAL INTRODUCTION TO FHA PROGRAMS Lead-Based Paint Poisoning Prevention § 200.800 Lead-based paint. The Lead-Based Paint Poisoning Prevention Act (42 U.S.C. 4821-4846), the Residential...

  15. 24 CFR 598.408 - Lead-based paint requirements.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 24 Housing and Urban Development 3 2011-04-01 2010-04-01 true Lead-based paint requirements. 598... DESIGNATIONS Post-Designation Requirements § 598.408 Lead-based paint requirements. The Lead-Based Paint Poisoning Prevention Act (42 U.S.C. 4821-4846), the Residential Lead-Based Paint Hazard Reduction Act...

  16. 24 CFR 200.800 - Lead-based paint.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 24 Housing and Urban Development 2 2012-04-01 2012-04-01 false Lead-based paint. 200.800 Section... DEVELOPMENT GENERAL INTRODUCTION TO FHA PROGRAMS Lead-Based Paint Poisoning Prevention § 200.800 Lead-based paint. The Lead-Based Paint Poisoning Prevention Act (42 U.S.C. 4821-4846), the Residential...

  17. HUD`s lead-based paint activities

    SciTech Connect

    Morony, R.

    1994-12-31

    Title X of Public Law 102-550 is a major piece of legislation for the Department having to do with lead-based paint. It changes the way the Department is going to be doing all of its work with lead-based paint in all areas except public housing. It is a mandate from Congress for a great deal of change. It is going to cause revisions in the regulations. Title X authorizes a grant program to State and local governments for the abatement of lead-based paint in low income, privately owned housing. This is an area that has not gotten attention from the Federal government before. The first series of grants have been awarded, some $46 million, to six States, three cities, and one county. The grantees have been selected for $91 million that will go to 19 winners. They received 63 applications, again from State and local governments, again for privately owned housing. There is a third grant series in this fiscal year. The applications for the $142 million are due July 5, 1994. Again, HUD is looking at privately owned housing. This is not housing that is, in most cases, federally assisted in any way.

  18. 24 CFR 511.15 - Lead-based paint.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 24 Housing and Urban Development 3 2013-04-01 2013-04-01 false Lead-based paint. 511.15 Section... Lead-based paint. The Lead-Based Paint Poisoning Prevention Act (42 U.S.C. 4821-4846), the Residential Lead-Based Paint Hazard Reduction Act of 1992 (42 U.S.C. 4851-4856), and implementing regulations...

  19. 24 CFR 574.635 - Lead-based paint.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 24 Housing and Urban Development 3 2012-04-01 2012-04-01 false Lead-based paint. 574.635 Section....635 Lead-based paint. The Lead-Based Paint Poisoning Prevention Act (42 U.S.C. 4821-4846), the Residential Lead-Based Paint Hazard Reduction Act of 1992 (42 U.S.C. 4851-4856), and implementing...

  20. 24 CFR 1003.607 - Lead-based paint.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 24 Housing and Urban Development 4 2014-04-01 2014-04-01 false Lead-based paint. 1003.607 Section... § 1003.607 Lead-based paint. The requirements of the Lead-Based Paint Poisoning Prevention Act (42 U.S.C. 4821-4846), the Residential Lead-Based Paint Hazard Reduction Act of 1992 (42 U.S.C. 4851-4856),...

  1. 24 CFR 574.635 - Lead-based paint.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 24 Housing and Urban Development 3 2014-04-01 2013-04-01 true Lead-based paint. 574.635 Section....635 Lead-based paint. The Lead-Based Paint Poisoning Prevention Act (42 U.S.C. 4821-4846), the Residential Lead-Based Paint Hazard Reduction Act of 1992 (42 U.S.C. 4851-4856), and implementing...

  2. 24 CFR 1003.607 - Lead-based paint.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 24 Housing and Urban Development 4 2013-04-01 2013-04-01 false Lead-based paint. 1003.607 Section... § 1003.607 Lead-based paint. The requirements of the Lead-Based Paint Poisoning Prevention Act (42 U.S.C. 4821-4846), the Residential Lead-Based Paint Hazard Reduction Act of 1992 (42 U.S.C. 4851-4856),...

  3. 24 CFR 511.15 - Lead-based paint.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 24 Housing and Urban Development 3 2012-04-01 2012-04-01 false Lead-based paint. 511.15 Section... Lead-based paint. The Lead-Based Paint Poisoning Prevention Act (42 U.S.C. 4821-4846), the Residential Lead-Based Paint Hazard Reduction Act of 1992 (42 U.S.C. 4851-4856), and implementing regulations...

  4. 24 CFR 574.635 - Lead-based paint.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 24 Housing and Urban Development 3 2011-04-01 2010-04-01 true Lead-based paint. 574.635 Section....635 Lead-based paint. The Lead-Based Paint Poisoning Prevention Act (42 U.S.C. 4821-4846), the Residential Lead-Based Paint Hazard Reduction Act of 1992 (42 U.S.C. 4851-4856), and implementing...

  5. 24 CFR 511.15 - Lead-based paint.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 24 Housing and Urban Development 3 2011-04-01 2010-04-01 true Lead-based paint. 511.15 Section 511... Lead-based paint. The Lead-Based Paint Poisoning Prevention Act (42 U.S.C. 4821-4846), the Residential Lead-Based Paint Hazard Reduction Act of 1992 (42 U.S.C. 4851-4856), and implementing regulations...

  6. 24 CFR 511.15 - Lead-based paint.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 24 Housing and Urban Development 3 2014-04-01 2013-04-01 true Lead-based paint. 511.15 Section 511... Lead-based paint. The Lead-Based Paint Poisoning Prevention Act (42 U.S.C. 4821-4846), the Residential Lead-Based Paint Hazard Reduction Act of 1992 (42 U.S.C. 4851-4856), and implementing regulations...

  7. 24 CFR 511.15 - Lead-based paint.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 3 2010-04-01 2010-04-01 false Lead-based paint. 511.15 Section... Lead-based paint. The Lead-Based Paint Poisoning Prevention Act (42 U.S.C. 4821-4846), the Residential Lead-Based Paint Hazard Reduction Act of 1992 (42 U.S.C. 4851-4856), and implementing regulations...

  8. 24 CFR 1003.607 - Lead-based paint.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 4 2010-04-01 2010-04-01 false Lead-based paint. 1003.607 Section... § 1003.607 Lead-based paint. The requirements of the Lead-Based Paint Poisoning Prevention Act (42 U.S.C. 4821-4846), the Residential Lead-Based Paint Hazard Reduction Act of 1992 (42 U.S.C. 4851-4856),...

  9. 24 CFR 1003.607 - Lead-based paint.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 24 Housing and Urban Development 4 2011-04-01 2011-04-01 false Lead-based paint. 1003.607 Section... § 1003.607 Lead-based paint. The requirements of the Lead-Based Paint Poisoning Prevention Act (42 U.S.C. 4821-4846), the Residential Lead-Based Paint Hazard Reduction Act of 1992 (42 U.S.C. 4851-4856),...

  10. 24 CFR 574.635 - Lead-based paint.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 24 Housing and Urban Development 3 2013-04-01 2013-04-01 false Lead-based paint. 574.635 Section....635 Lead-based paint. The Lead-Based Paint Poisoning Prevention Act (42 U.S.C. 4821-4846), the Residential Lead-Based Paint Hazard Reduction Act of 1992 (42 U.S.C. 4851-4856), and implementing...

  11. 24 CFR 1003.607 - Lead-based paint.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 24 Housing and Urban Development 4 2012-04-01 2012-04-01 false Lead-based paint. 1003.607 Section... § 1003.607 Lead-based paint. The requirements of the Lead-Based Paint Poisoning Prevention Act (42 U.S.C. 4821-4846), the Residential Lead-Based Paint Hazard Reduction Act of 1992 (42 U.S.C. 4851-4856),...

  12. 24 CFR 574.635 - Lead-based paint.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 3 2010-04-01 2010-04-01 false Lead-based paint. 574.635 Section....635 Lead-based paint. The Lead-Based Paint Poisoning Prevention Act (42 U.S.C. 4821-4846), the Residential Lead-Based Paint Hazard Reduction Act of 1992 (42 U.S.C. 4851-4856), and implementing...

  13. 24 CFR 891.325 - Lead-based paint requirements.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 24 Housing and Urban Development 4 2013-04-01 2013-04-01 false Lead-based paint requirements. 891... Section 811 Supportive Housing for Persons With Disabilities § 891.325 Lead-based paint requirements. The requirements of the Lead-Based Paint Poisoning Prevention Act (42 U.S.C. 4821-4846), the Residential...

  14. 24 CFR 92.355 - Lead-based paint.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 24 Housing and Urban Development 1 2012-04-01 2012-04-01 false Lead-based paint. 92.355 Section 92... HOME INVESTMENT PARTNERSHIPS PROGRAM Other Federal Requirements § 92.355 Lead-based paint. Housing assisted with HOME funds is subject to the Lead-Based Paint Poisoning Prevention Act (42 U.S.C....

  15. 24 CFR 92.355 - Lead-based paint.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 24 Housing and Urban Development 1 2014-04-01 2014-04-01 false Lead-based paint. 92.355 Section 92... HOME INVESTMENT PARTNERSHIPS PROGRAM Other Federal Requirements § 92.355 Lead-based paint. Housing assisted with HOME funds is subject to the Lead-Based Paint Poisoning Prevention Act (42 U.S.C....

  16. 24 CFR 92.355 - Lead-based paint.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 1 2010-04-01 2010-04-01 false Lead-based paint. 92.355 Section 92... HOME INVESTMENT PARTNERSHIPS PROGRAM Other Federal Requirements § 92.355 Lead-based paint. Housing assisted with HOME funds is subject to the Lead-Based Paint Poisoning Prevention Act (42 U.S.C....

  17. 24 CFR 570.608 - Lead-based paint.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 24 Housing and Urban Development 3 2013-04-01 2013-04-01 false Lead-based paint. 570.608 Section... DEVELOPMENT COMMUNITY FACILITIES COMMUNITY DEVELOPMENT BLOCK GRANTS Other Program Requirements § 570.608 Lead-based paint. The Lead-Based Paint Poisoning Prevention Act (42 U.S.C. 4821-4846), the Residential...

  18. 24 CFR 92.355 - Lead-based paint.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 24 Housing and Urban Development 1 2011-04-01 2011-04-01 false Lead-based paint. 92.355 Section 92... HOME INVESTMENT PARTNERSHIPS PROGRAM Other Federal Requirements § 92.355 Lead-based paint. Housing assisted with HOME funds is subject to the Lead-Based Paint Poisoning Prevention Act (42 U.S.C....

  19. 24 CFR 891.325 - Lead-based paint requirements.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 24 Housing and Urban Development 4 2014-04-01 2014-04-01 false Lead-based paint requirements. 891... Section 811 Supportive Housing for Persons With Disabilities § 891.325 Lead-based paint requirements. The requirements of the Lead-Based Paint Poisoning Prevention Act (42 U.S.C. 4821-4846), the Residential...

  20. 24 CFR 570.608 - Lead-based paint.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 24 Housing and Urban Development 3 2011-04-01 2010-04-01 true Lead-based paint. 570.608 Section... DEVELOPMENT COMMUNITY FACILITIES COMMUNITY DEVELOPMENT BLOCK GRANTS Other Program Requirements § 570.608 Lead-based paint. The Lead-Based Paint Poisoning Prevention Act (42 U.S.C. 4821-4846), the Residential...

  1. 24 CFR 92.355 - Lead-based paint.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 24 Housing and Urban Development 1 2013-04-01 2013-04-01 false Lead-based paint. 92.355 Section 92... HOME INVESTMENT PARTNERSHIPS PROGRAM Other Federal Requirements § 92.355 Lead-based paint. Housing assisted with HOME funds is subject to the Lead-Based Paint Poisoning Prevention Act (42 U.S.C....

  2. 24 CFR 891.325 - Lead-based paint requirements.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 4 2010-04-01 2010-04-01 false Lead-based paint requirements. 891... Section 811 Supportive Housing for Persons With Disabilities § 891.325 Lead-based paint requirements. The requirements of the Lead-Based Paint Poisoning Prevention Act (42 U.S.C. 4821-4846), the Residential...

  3. 24 CFR 570.608 - Lead-based paint.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 3 2010-04-01 2010-04-01 false Lead-based paint. 570.608 Section... DEVELOPMENT COMMUNITY FACILITIES COMMUNITY DEVELOPMENT BLOCK GRANTS Other Program Requirements § 570.608 Lead-based paint. The Lead-Based Paint Poisoning Prevention Act (42 U.S.C. 4821-4846), the Residential...

  4. 24 CFR 570.608 - Lead-based paint.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 24 Housing and Urban Development 3 2014-04-01 2013-04-01 true Lead-based paint. 570.608 Section... DEVELOPMENT COMMUNITY FACILITIES COMMUNITY DEVELOPMENT BLOCK GRANTS Other Program Requirements § 570.608 Lead-based paint. The Lead-Based Paint Poisoning Prevention Act (42 U.S.C. 4821-4846), the Residential...

  5. 24 CFR 570.608 - Lead-based paint.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 24 Housing and Urban Development 3 2012-04-01 2012-04-01 false Lead-based paint. 570.608 Section... DEVELOPMENT COMMUNITY FACILITIES COMMUNITY DEVELOPMENT BLOCK GRANTS Other Program Requirements § 570.608 Lead-based paint. The Lead-Based Paint Poisoning Prevention Act (42 U.S.C. 4821-4846), the Residential...

  6. 24 CFR 891.325 - Lead-based paint requirements.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 24 Housing and Urban Development 4 2011-04-01 2011-04-01 false Lead-based paint requirements. 891... Section 811 Supportive Housing for Persons With Disabilities § 891.325 Lead-based paint requirements. The requirements of the Lead-Based Paint Poisoning Prevention Act (42 U.S.C. 4821-4846), the Residential...

  7. 24 CFR 891.325 - Lead-based paint requirements.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 24 Housing and Urban Development 4 2012-04-01 2012-04-01 false Lead-based paint requirements. 891... Section 811 Supportive Housing for Persons With Disabilities § 891.325 Lead-based paint requirements. The requirements of the Lead-Based Paint Poisoning Prevention Act (42 U.S.C. 4821-4846), the Residential...

  8. 13 CFR 120.173 - Lead-based paint.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 13 Business Credit and Assistance 1 2010-01-01 2010-01-01 false Lead-based paint. 120.173 Section... to All Business Loans Requirements Imposed Under Other Laws and Orders § 120.173 Lead-based paint. If loan proceeds are for the construction or rehabilitation of a residential structure, lead-based...

  9. 13 CFR 120.173 - Lead-based paint.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 13 Business Credit and Assistance 1 2014-01-01 2014-01-01 false Lead-based paint. 120.173 Section... to All Business Loans Requirements Imposed Under Other Laws and Orders § 120.173 Lead-based paint. If loan proceeds are for the construction or rehabilitation of a residential structure, lead-based...

  10. 13 CFR 120.173 - Lead-based paint.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 13 Business Credit and Assistance 1 2013-01-01 2013-01-01 false Lead-based paint. 120.173 Section... to All Business Loans Requirements Imposed Under Other Laws and Orders § 120.173 Lead-based paint. If loan proceeds are for the construction or rehabilitation of a residential structure, lead-based...

  11. 13 CFR 120.173 - Lead-based paint.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 13 Business Credit and Assistance 1 2011-01-01 2011-01-01 false Lead-based paint. 120.173 Section... to All Business Loans Requirements Imposed Under Other Laws and Orders § 120.173 Lead-based paint. If loan proceeds are for the construction or rehabilitation of a residential structure, lead-based...

  12. 13 CFR 120.173 - Lead-based paint.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 13 Business Credit and Assistance 1 2012-01-01 2012-01-01 false Lead-based paint. 120.173 Section... to All Business Loans Requirements Imposed Under Other Laws and Orders § 120.173 Lead-based paint. If loan proceeds are for the construction or rehabilitation of a residential structure, lead-based...

  13. 40 CFR 745.233 - Lead-based paint activities requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Lead-based paint activities...) TOXIC SUBSTANCES CONTROL ACT LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Lead-Based Paint Activities § 745.233 Lead-based paint activities requirements. Lead-based...

  14. 40 CFR 745.233 - Lead-based paint activities requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Lead-based paint activities...) TOXIC SUBSTANCES CONTROL ACT LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Lead-Based Paint Activities § 745.233 Lead-based paint activities requirements. Lead-based...

  15. 40 CFR 745.233 - Lead-based paint activities requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Lead-based paint activities...) TOXIC SUBSTANCES CONTROL ACT LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Lead-Based Paint Activities § 745.233 Lead-based paint activities requirements. Lead-based...

  16. 40 CFR 745.233 - Lead-based paint activities requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Lead-based paint activities...) TOXIC SUBSTANCES CONTROL ACT LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Lead-Based Paint Activities § 745.233 Lead-based paint activities requirements. Lead-based...

  17. 40 CFR 745.233 - Lead-based paint activities requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Lead-based paint activities...) TOXIC SUBSTANCES CONTROL ACT LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Lead-Based Paint Activities § 745.233 Lead-based paint activities requirements. Lead-based...

  18. Glass composition development for stabilization of lead based paints

    SciTech Connect

    Marra, J.C.

    1996-10-01

    Exposure to lead can lead to adverse health affects including permanent damage to the central nervous system. Common means of exposure to lead are from ingestion of lead paint chips or breathing of dust from deteriorating painted surfaces. The U.S. Army has over 101 million square feet of buildings dating to World War II or earlier. Many of these structures were built before the 1978 ban on lead based paints. The U.S. Army Corps of Engineers CERL is developing technologies to remove and stabilize lead containing organic coatings. Promising results have been achieved using a patented flame spray process that utilizes a glass frit to stabilize the hazardous constituents. When the glass frit is sprayed onto the paint containing substrate, differences in thermal expansion coefficients between the frit and the paint results in spalling of the paint from the substrate surface. The removed fragments are then collected and remelted to stabilize the hazardous constituents and allow for disposal as non-hazardous waste. Similar successful results using a patented process involving microwave technology for paint removal have also been achieved. In this process, the painted surface is coated with a microwave coupling compound that when exposed to microwave energy results in the spalling of the hazardous paint from the surface. The fragments can again be accumulated and remelted for stabilization and disposal.

  19. 40 CFR 745.65 - Lead-based paint hazards.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... by EPA at 40 CFR part 745, subpart L and in regulations issued by the Department of Housing and Urban Development (HUD) at 24 CFR part 35, subpart R. The work practice standards in those regulations do not apply... following: (1) Any lead-based paint on a friction surface that is subject to abrasion and where the...

  20. 40 CFR 745.65 - Lead-based paint hazards.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... by EPA at 40 CFR part 745, subpart L and in regulations issued by the Department of Housing and Urban Development (HUD) at 24 CFR part 35, subpart R. The work practice standards in those regulations do not apply... following: (1) Any lead-based paint on a friction surface that is subject to abrasion and where the...

  1. 40 CFR 745.65 - Lead-based paint hazards.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... by EPA at 40 CFR part 745, subpart L and in regulations issued by the Department of Housing and Urban Development (HUD) at 24 CFR part 35, subpart R. The work practice standards in those regulations do not apply... following: (1) Any lead-based paint on a friction surface that is subject to abrasion and where the...

  2. 40 CFR 745.65 - Lead-based paint hazards.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... by EPA at 40 CFR part 745, subpart L and in regulations issued by the Department of Housing and Urban Development (HUD) at 24 CFR part 35, subpart R. The work practice standards in those regulations do not apply... following: (1) Any lead-based paint on a friction surface that is subject to abrasion and where the...

  3. 24 CFR 965.701 - Lead-based paint poisoning prevention.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 4 2010-04-01 2010-04-01 false Lead-based paint poisoning... URBAN DEVELOPMENT PHA-OWNED OR LEASED PROJECTS-GENERAL PROVISIONS Lead-Based Paint Poisoning Prevention § 965.701 Lead-based paint poisoning prevention. The requirements of the Lead-Based Paint...

  4. 24 CFR 965.701 - Lead-based paint poisoning prevention.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 24 Housing and Urban Development 4 2014-04-01 2014-04-01 false Lead-based paint poisoning... URBAN DEVELOPMENT PHA-OWNED OR LEASED PROJECTS-GENERAL PROVISIONS Lead-Based Paint Poisoning Prevention § 965.701 Lead-based paint poisoning prevention. The requirements of the Lead-Based Paint...

  5. 24 CFR 965.701 - Lead-based paint poisoning prevention.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 24 Housing and Urban Development 4 2013-04-01 2013-04-01 false Lead-based paint poisoning... URBAN DEVELOPMENT PHA-OWNED OR LEASED PROJECTS-GENERAL PROVISIONS Lead-Based Paint Poisoning Prevention § 965.701 Lead-based paint poisoning prevention. The requirements of the Lead-Based Paint...

  6. 24 CFR 965.701 - Lead-based paint poisoning prevention.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 24 Housing and Urban Development 4 2011-04-01 2011-04-01 false Lead-based paint poisoning... URBAN DEVELOPMENT PHA-OWNED OR LEASED PROJECTS-GENERAL PROVISIONS Lead-Based Paint Poisoning Prevention § 965.701 Lead-based paint poisoning prevention. The requirements of the Lead-Based Paint...

  7. 24 CFR 965.701 - Lead-based paint poisoning prevention.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 24 Housing and Urban Development 4 2012-04-01 2012-04-01 false Lead-based paint poisoning... URBAN DEVELOPMENT PHA-OWNED OR LEASED PROJECTS-GENERAL PROVISIONS Lead-Based Paint Poisoning Prevention § 965.701 Lead-based paint poisoning prevention. The requirements of the Lead-Based Paint...

  8. 40 CFR 745.325 - Lead-based paint activities: State and Tribal program requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES State and Indian Tribal Programs § 745.325 Lead-based paint activities: State and... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Lead-based paint activities: State...

  9. 40 CFR 745.325 - Lead-based paint activities: State and Tribal program requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES State and Indian Tribal Programs § 745.325 Lead-based paint activities: State and... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Lead-based paint activities: State...

  10. 40 CFR 745.325 - Lead-based paint activities: State and Tribal program requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES State and Indian Tribal Programs § 745.325 Lead-based paint activities: State and... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Lead-based paint activities: State...

  11. 40 CFR 745.325 - Lead-based paint activities: State and Tribal program requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES State and Indian Tribal Programs § 745.325 Lead-based paint activities: State and... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Lead-based paint activities: State...

  12. 48 CFR 452.236-71 - Prohibition Against the Use of Lead-Based Paint.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Use of Lead-Based Paint. 452.236-71 Section 452.236-71 Federal Acquisition Regulations System... and Clauses 452.236-71 Prohibition Against the Use of Lead-Based Paint. As prescribed in 436.571, insert the following clause: Prohibition Against the Use of Lead-Based Paint (NOV 1996) Neither...

  13. 24 CFR 291.430 - Elimination of lead-based paint hazards.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 2 2010-04-01 2010-04-01 false Elimination of lead-based paint... Lease and Sale of HUD-Acquired Single Family Properties for the Homeless § 291.430 Elimination of lead-based paint hazards. The Lead-Based Paint Poisoning Prevention Act (42 U.S.C. 4821-4846),...

  14. 24 CFR 35.935 - Ongoing lead-based paint maintenance activities.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 24 Housing and Urban Development 1 2012-04-01 2012-04-01 false Ongoing lead-based paint..., Department of Housing and Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Rehabilitation § 35.935 Ongoing lead-based paint maintenance activities. In the case of a...

  15. 24 CFR 291.430 - Elimination of lead-based paint hazards.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 24 Housing and Urban Development 2 2012-04-01 2012-04-01 false Elimination of lead-based paint... Lease and Sale of HUD-Acquired Single Family Properties for the Homeless § 291.430 Elimination of lead-based paint hazards. The Lead-Based Paint Poisoning Prevention Act (42 U.S.C. 4821-4846),...

  16. 24 CFR 35.1220 - Ongoing lead-based paint maintenance activities.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 24 Housing and Urban Development 1 2013-04-01 2013-04-01 false Ongoing lead-based paint..., Department of Housing and Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Tenant-Based Rental Assistance § 35.1220 Ongoing lead-based paint maintenance...

  17. 24 CFR 35.1220 - Ongoing lead-based paint maintenance activities.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 1 2010-04-01 2010-04-01 false Ongoing lead-based paint..., Department of Housing and Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Tenant-Based Rental Assistance § 35.1220 Ongoing lead-based paint maintenance...

  18. 48 CFR 436.571 - Prohibition against the use of lead-based paint.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... use of lead-based paint. 436.571 Section 436.571 Federal Acquisition Regulations System DEPARTMENT OF... 436.571 Prohibition against the use of lead-based paint. The contracting officer shall insert the clause at 452.236-71, Prohibition Against the Use of Lead-Based Paint, in solicitations and contracts,...

  19. 24 CFR 35.935 - Ongoing lead-based paint maintenance activities.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 24 Housing and Urban Development 1 2014-04-01 2014-04-01 false Ongoing lead-based paint..., Department of Housing and Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Rehabilitation § 35.935 Ongoing lead-based paint maintenance activities. In the case of a...

  20. 24 CFR 35.1220 - Ongoing lead-based paint maintenance activities.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 24 Housing and Urban Development 1 2012-04-01 2012-04-01 false Ongoing lead-based paint..., Department of Housing and Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Tenant-Based Rental Assistance § 35.1220 Ongoing lead-based paint maintenance...

  1. 24 CFR 35.935 - Ongoing lead-based paint maintenance activities.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 1 2010-04-01 2010-04-01 false Ongoing lead-based paint..., Department of Housing and Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Rehabilitation § 35.935 Ongoing lead-based paint maintenance activities. In the case of a...

  2. 24 CFR 35.935 - Ongoing lead-based paint maintenance activities.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 24 Housing and Urban Development 1 2013-04-01 2013-04-01 false Ongoing lead-based paint..., Department of Housing and Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Rehabilitation § 35.935 Ongoing lead-based paint maintenance activities. In the case of a...

  3. 24 CFR 291.430 - Elimination of lead-based paint hazards.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 24 Housing and Urban Development 2 2014-04-01 2014-04-01 false Elimination of lead-based paint... Lease and Sale of HUD-Acquired Single Family Properties for the Homeless § 291.430 Elimination of lead-based paint hazards. The Lead-Based Paint Poisoning Prevention Act (42 U.S.C. 4821-4846),...

  4. 24 CFR 965.215 - Lead-based paint liability insurance coverage.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 24 Housing and Urban Development 4 2013-04-01 2013-04-01 false Lead-based paint liability... Insurance Coverage § 965.215 Lead-based paint liability insurance coverage. (a) General. The purpose of this... with lead-based paint activities that the PHA undertakes, in accordance with the PHA's ACC with...

  5. 24 CFR 965.215 - Lead-based paint liability insurance coverage.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 24 Housing and Urban Development 4 2011-04-01 2011-04-01 false Lead-based paint liability... Insurance Coverage § 965.215 Lead-based paint liability insurance coverage. (a) General. The purpose of this... with lead-based paint activities that the PHA undertakes, in accordance with the PHA's ACC with...

  6. 24 CFR 291.430 - Elimination of lead-based paint hazards.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 24 Housing and Urban Development 2 2013-04-01 2013-04-01 false Elimination of lead-based paint... Lease and Sale of HUD-Acquired Single Family Properties for the Homeless § 291.430 Elimination of lead-based paint hazards. The Lead-Based Paint Poisoning Prevention Act (42 U.S.C. 4821-4846),...

  7. 48 CFR 1436.570 - Prohibition against use of lead-based paint.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... lead-based paint. 1436.570 Section 1436.570 Federal Acquisition Regulations System DEPARTMENT OF THE... 1436.570 Prohibition against use of lead-based paint. (a) Definitions. As used in this section... of Lead-Based Paint, in solicitations and contracts when construction of residential structures...

  8. 48 CFR 1436.570 - Prohibition against use of lead-based paint.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... lead-based paint. 1436.570 Section 1436.570 Federal Acquisition Regulations System DEPARTMENT OF THE... 1436.570 Prohibition against use of lead-based paint. (a) Definitions. As used in this section... of Lead-Based Paint, in solicitations and contracts when construction of residential structures...

  9. 48 CFR 1436.570 - Prohibition against use of lead-based paint.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... lead-based paint. 1436.570 Section 1436.570 Federal Acquisition Regulations System DEPARTMENT OF THE... 1436.570 Prohibition against use of lead-based paint. (a) Definitions. As used in this section... of Lead-Based Paint, in solicitations and contracts when construction of residential structures...

  10. 24 CFR 35.1220 - Ongoing lead-based paint maintenance activities.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 24 Housing and Urban Development 1 2011-04-01 2011-04-01 false Ongoing lead-based paint..., Department of Housing and Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Tenant-Based Rental Assistance § 35.1220 Ongoing lead-based paint maintenance...

  11. 40 CFR 745.325 - Lead-based paint activities: State and Tribal program requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Lead-based paint activities: State and... AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES State and Indian Tribal Programs § 745.325 Lead-based paint activities: State...

  12. 24 CFR 35.935 - Ongoing lead-based paint maintenance activities.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 24 Housing and Urban Development 1 2011-04-01 2011-04-01 false Ongoing lead-based paint..., Department of Housing and Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Rehabilitation § 35.935 Ongoing lead-based paint maintenance activities. In the case of a...

  13. 24 CFR 965.215 - Lead-based paint liability insurance coverage.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 24 Housing and Urban Development 4 2012-04-01 2012-04-01 false Lead-based paint liability... Insurance Coverage § 965.215 Lead-based paint liability insurance coverage. (a) General. The purpose of this... with lead-based paint activities that the PHA undertakes, in accordance with the PHA's ACC with...

  14. 24 CFR 965.215 - Lead-based paint liability insurance coverage.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 4 2010-04-01 2010-04-01 false Lead-based paint liability... Insurance Coverage § 965.215 Lead-based paint liability insurance coverage. (a) General. The purpose of this... with lead-based paint activities that the PHA undertakes, in accordance with the PHA's ACC with...

  15. 24 CFR 965.215 - Lead-based paint liability insurance coverage.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 24 Housing and Urban Development 4 2014-04-01 2014-04-01 false Lead-based paint liability... Insurance Coverage § 965.215 Lead-based paint liability insurance coverage. (a) General. The purpose of this... with lead-based paint activities that the PHA undertakes, in accordance with the PHA's ACC with...

  16. 48 CFR 1436.570 - Prohibition against use of lead-based paint.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... lead-based paint. 1436.570 Section 1436.570 Federal Acquisition Regulations System DEPARTMENT OF THE... 1436.570 Prohibition against use of lead-based paint. (a) Definitions. As used in this section... of Lead-Based Paint, in solicitations and contracts when construction of residential structures...

  17. 24 CFR 35.1220 - Ongoing lead-based paint maintenance activities.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 24 Housing and Urban Development 1 2014-04-01 2014-04-01 false Ongoing lead-based paint..., Department of Housing and Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Tenant-Based Rental Assistance § 35.1220 Ongoing lead-based paint maintenance...

  18. 24 CFR 291.430 - Elimination of lead-based paint hazards.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 24 Housing and Urban Development 2 2011-04-01 2011-04-01 false Elimination of lead-based paint... Lease and Sale of HUD-Acquired Single Family Properties for the Homeless § 291.430 Elimination of lead-based paint hazards. The Lead-Based Paint Poisoning Prevention Act (42 U.S.C. 4821-4846),...

  19. 48 CFR 1436.570 - Prohibition against use of lead-based paint.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... lead-based paint. 1436.570 Section 1436.570 Federal Acquisition Regulations System DEPARTMENT OF THE... 1436.570 Prohibition against use of lead-based paint. (a) Definitions. As used in this section... of Lead-Based Paint, in solicitations and contracts when construction of residential structures...

  20. 48 CFR 436.571 - Prohibition against the use of lead-based paint.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... use of lead-based paint. 436.571 Section 436.571 Federal Acquisition Regulations System DEPARTMENT OF... 436.571 Prohibition against the use of lead-based paint. The contracting officer shall insert the clause at 452.236-71, Prohibition Against the Use of Lead-Based Paint, in solicitations and contracts,...

  1. 48 CFR 452.236-71 - Prohibition Against the Use of Lead-Based Paint.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Use of Lead-Based Paint. 452.236-71 Section 452.236-71 Federal Acquisition Regulations System... and Clauses 452.236-71 Prohibition Against the Use of Lead-Based Paint. As prescribed in 436.571, insert the following clause: Prohibition Against the Use of Lead-Based Paint (NOV 1996) Neither...

  2. 48 CFR 436.571 - Prohibition against the use of lead-based paint.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... use of lead-based paint. 436.571 Section 436.571 Federal Acquisition Regulations System DEPARTMENT OF... 436.571 Prohibition against the use of lead-based paint. The contracting officer shall insert the clause at 452.236-71, Prohibition Against the Use of Lead-Based Paint, in solicitations and contracts,...

  3. 48 CFR 452.236-71 - Prohibition Against the Use of Lead-Based Paint.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Use of Lead-Based Paint. 452.236-71 Section 452.236-71 Federal Acquisition Regulations System... and Clauses 452.236-71 Prohibition Against the Use of Lead-Based Paint. As prescribed in 436.571, insert the following clause: Prohibition Against the Use of Lead-Based Paint (NOV 1996) Neither...

  4. 48 CFR 436.571 - Prohibition against the use of lead-based paint.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... use of lead-based paint. 436.571 Section 436.571 Federal Acquisition Regulations System DEPARTMENT OF... 436.571 Prohibition against the use of lead-based paint. The contracting officer shall insert the clause at 452.236-71, Prohibition Against the Use of Lead-Based Paint, in solicitations and contracts,...

  5. 48 CFR 452.236-71 - Prohibition Against the Use of Lead-Based Paint.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Use of Lead-Based Paint. 452.236-71 Section 452.236-71 Federal Acquisition Regulations System... and Clauses 452.236-71 Prohibition Against the Use of Lead-Based Paint. As prescribed in 436.571, insert the following clause: Prohibition Against the Use of Lead-Based Paint (NOV 1996) Neither...

  6. 48 CFR 452.236-71 - Prohibition Against the Use of Lead-Based Paint.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Use of Lead-Based Paint. 452.236-71 Section 452.236-71 Federal Acquisition Regulations System... and Clauses 452.236-71 Prohibition Against the Use of Lead-Based Paint. As prescribed in 436.571, insert the following clause: Prohibition Against the Use of Lead-Based Paint (NOV 1996) Neither...

  7. 48 CFR 436.571 - Prohibition against the use of lead-based paint.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... use of lead-based paint. 436.571 Section 436.571 Federal Acquisition Regulations System DEPARTMENT OF... 436.571 Prohibition against the use of lead-based paint. The contracting officer shall insert the clause at 452.236-71, Prohibition Against the Use of Lead-Based Paint, in solicitations and contracts,...

  8. FIELD DEMONSTRATION OF LEAD PAINT ABATEMENT TECHNOLOGIES IN RESIDENTIAL HOUSING

    EPA Science Inventory

    This study was conducted to demonstrate lead-based paint (LBP) removal from architectural wood components in CO2 unoccupied residential housing using four technologies: granular carbon dioxide (CO2 blasting), pelletized CO2 blasting, encapsulant paint remover, and wet abrasive bl...

  9. 77 FR 57106 - Notice of Proposed Information Collection: Requirements for Notification of Lead-Based Paint...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-17

    ... Paint Hazards in Federally-Owned Residential Properties and Housing Receiving Federal Assistance AGENCY... Notification of Lead-Based Paint Hazards in Federally-Owned Residential Properties and Housing Receiving... Information and Proposed Use: Requirements for notification of lead-based paint hazard in federally-...

  10. 48 CFR 1452.236-70 - Prohibition Against Use of Lead-based Paint.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Lead-based Paint. 1452.236-70 Section 1452.236-70 Federal Acquisition Regulations System DEPARTMENT OF... Clauses 1452.236-70 Prohibition Against Use of Lead-based Paint. As prescribed in 1436.570(b), insert the following clause: Prohibition Against Use of Lead-Based Paint—Department of the Interior (JUL 1996)...

  11. 24 CFR 570.461 - Post-preliminary approval requirements; lead-based paint.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... requirements; lead-based paint. 570.461 Section 570.461 Housing and Urban Development Regulations Relating to... GRANTS Urban Development Action Grants § 570.461 Post-preliminary approval requirements; lead-based paint. The recipient may receive preliminary approval prior to the accomplishment of lead-based...

  12. 24 CFR 35.825 - Ongoing lead-based paint maintenance and reevaluation.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 24 Housing and Urban Development 1 2012-04-01 2012-04-01 false Ongoing lead-based paint..., Department of Housing and Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES HUD-Owned and Mortgagee-in-Possession Multifamily Property § 35.825 Ongoing lead-based...

  13. 24 CFR 570.461 - Post-preliminary approval requirements; lead-based paint.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... requirements; lead-based paint. 570.461 Section 570.461 Housing and Urban Development Regulations Relating to... GRANTS Urban Development Action Grants § 570.461 Post-preliminary approval requirements; lead-based paint. The recipient may receive preliminary approval prior to the accomplishment of lead-based...

  14. 24 CFR 35.825 - Ongoing lead-based paint maintenance and reevaluation.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 24 Housing and Urban Development 1 2013-04-01 2013-04-01 false Ongoing lead-based paint..., Department of Housing and Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES HUD-Owned and Mortgagee-in-Possession Multifamily Property § 35.825 Ongoing lead-based...

  15. 24 CFR 35.825 - Ongoing lead-based paint maintenance and reevaluation.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 24 Housing and Urban Development 1 2011-04-01 2011-04-01 false Ongoing lead-based paint..., Department of Housing and Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES HUD-Owned and Mortgagee-in-Possession Multifamily Property § 35.825 Ongoing lead-based...

  16. 48 CFR 1452.236-70 - Prohibition Against Use of Lead-based Paint.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Lead-based Paint. 1452.236-70 Section 1452.236-70 Federal Acquisition Regulations System DEPARTMENT OF... Clauses 1452.236-70 Prohibition Against Use of Lead-based Paint. As prescribed in 1436.570(b), insert the following clause: Prohibition Against Use of Lead-Based Paint—Department of the Interior (JUL 1996)...

  17. 24 CFR 570.461 - Post-preliminary approval requirements; lead-based paint.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... requirements; lead-based paint. 570.461 Section 570.461 Housing and Urban Development Regulations Relating to... GRANTS Urban Development Action Grants § 570.461 Post-preliminary approval requirements; lead-based paint. The recipient may receive preliminary approval prior to the accomplishment of lead-based...

  18. 24 CFR 35.825 - Ongoing lead-based paint maintenance and reevaluation.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 1 2010-04-01 2010-04-01 false Ongoing lead-based paint..., Department of Housing and Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES HUD-Owned and Mortgagee-in-Possession Multifamily Property § 35.825 Ongoing lead-based...

  19. 24 CFR 570.461 - Post-preliminary approval requirements; lead-based paint.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... requirements; lead-based paint. 570.461 Section 570.461 Housing and Urban Development Regulations Relating to... GRANTS Urban Development Action Grants § 570.461 Post-preliminary approval requirements; lead-based paint. The recipient may receive preliminary approval prior to the accomplishment of lead-based...

  20. 48 CFR 1452.236-70 - Prohibition Against Use of Lead-based Paint.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Lead-based Paint. 1452.236-70 Section 1452.236-70 Federal Acquisition Regulations System DEPARTMENT OF... Clauses 1452.236-70 Prohibition Against Use of Lead-based Paint. As prescribed in 1436.570(b), insert the following clause: Prohibition Against Use of Lead-Based Paint—Department of the Interior (JUL 1996)...

  1. 48 CFR 1452.236-70 - Prohibition Against Use of Lead-based Paint.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Lead-based Paint. 1452.236-70 Section 1452.236-70 Federal Acquisition Regulations System DEPARTMENT OF... Clauses 1452.236-70 Prohibition Against Use of Lead-based Paint. As prescribed in 1436.570(b), insert the following clause: Prohibition Against Use of Lead-Based Paint—Department of the Interior (JUL 1996)...

  2. 24 CFR 35.825 - Ongoing lead-based paint maintenance and reevaluation.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 24 Housing and Urban Development 1 2014-04-01 2014-04-01 false Ongoing lead-based paint..., Department of Housing and Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES HUD-Owned and Mortgagee-in-Possession Multifamily Property § 35.825 Ongoing lead-based...

  3. 24 CFR 570.461 - Post-preliminary approval requirements; lead-based paint.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... requirements; lead-based paint. 570.461 Section 570.461 Housing and Urban Development Regulations Relating to... GRANTS Urban Development Action Grants § 570.461 Post-preliminary approval requirements; lead-based paint. The recipient may receive preliminary approval prior to the accomplishment of lead-based...

  4. 48 CFR 1452.236-70 - Prohibition Against Use of Lead-based Paint.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Lead-based Paint. 1452.236-70 Section 1452.236-70 Federal Acquisition Regulations System DEPARTMENT OF... Clauses 1452.236-70 Prohibition Against Use of Lead-based Paint. As prescribed in 1436.570(b), insert the following clause: Prohibition Against Use of Lead-Based Paint—Department of the Interior (JUL 1996)...

  5. Lead paint abatement -- A technological review

    SciTech Connect

    Draper, A.C. III; Kapuscik, D.

    1994-12-31

    Abatement of lead from various surfaces proves to be a rapidly developing industry. Removal techniques and effectiveness varies greatly with varying substrates (wood, concrete, steel, etc.) and surface configurations including interior/exterior considerations, habitability and anticipated retrofit. Numerous technologies advances, and/or adaptations of long accepted removal techniques have recently emerged. Some of the more commonly used removal procedures including vacuum blasting, chemical stripping, scarifiers, grinders, sanders, etc. will be reviewed. Specific emphasis will be placed upon mode of application, positive and negative environmental aspects, and varying emissions generated. Personnel sampling data will be discussed with respect to associated personal protective equipment impact to derive the most cost productive environmentally conscious alternatives.

  6. 40 CFR 745.230 - Work practice standards for conducting lead-based paint activities: public and commercial...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... CONTROL ACT LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Lead-Based Paint Activities § 745.230 Work practice standards for conducting lead-based paint activities: public and... lead-based paint activities: public and commercial buildings, bridges and superstructures....

  7. 40 CFR 745.226 - Certification of individuals and firms engaged in lead-based paint activities: target housing and...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Lead-Based Paint Activities § 745.226 Certification of individuals and firms engaged in lead-based paint activities: target housing... engaged in lead-based paint activities: target housing and child-occupied facilities. 745.226 Section...

  8. 40 CFR 745.229 - Certification of individuals and firms engaged in lead-based paint activities: public and...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... SUBSTANCES CONTROL ACT LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Lead-Based Paint Activities § 745.229 Certification of individuals and firms engaged in lead-based paint activities... engaged in lead-based paint activities: public and commercial buildings, bridges and superstructures....

  9. 40 CFR 745.229 - Certification of individuals and firms engaged in lead-based paint activities: public and...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... SUBSTANCES CONTROL ACT LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Lead-Based Paint Activities § 745.229 Certification of individuals and firms engaged in lead-based paint activities... engaged in lead-based paint activities: public and commercial buildings, bridges and superstructures....

  10. 40 CFR 745.230 - Work practice standards for conducting lead-based paint activities: public and commercial...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... CONTROL ACT LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Lead-Based Paint Activities § 745.230 Work practice standards for conducting lead-based paint activities: public and... lead-based paint activities: public and commercial buildings, bridges and superstructures....

  11. 40 CFR 745.226 - Certification of individuals and firms engaged in lead-based paint activities: target housing and...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Lead-Based Paint Activities § 745.226 Certification of individuals and firms engaged in lead-based paint activities: target housing... engaged in lead-based paint activities: target housing and child-occupied facilities. 745.226 Section...

  12. 40 CFR 745.226 - Certification of individuals and firms engaged in lead-based paint activities: target housing and...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Lead-Based Paint Activities § 745.226 Certification of individuals and firms engaged in lead-based paint activities: target housing... engaged in lead-based paint activities: target housing and child-occupied facilities. 745.226 Section...

  13. 40 CFR 745.230 - Work practice standards for conducting lead-based paint activities: public and commercial...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... CONTROL ACT LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Lead-Based Paint Activities § 745.230 Work practice standards for conducting lead-based paint activities: public and... lead-based paint activities: public and commercial buildings, bridges and superstructures....

  14. 40 CFR 745.230 - Work practice standards for conducting lead-based paint activities: public and commercial...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... CONTROL ACT LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Lead-Based Paint Activities § 745.230 Work practice standards for conducting lead-based paint activities: public and... lead-based paint activities: public and commercial buildings, bridges and superstructures....

  15. 40 CFR 745.229 - Certification of individuals and firms engaged in lead-based paint activities: public and...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... SUBSTANCES CONTROL ACT LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Lead-Based Paint Activities § 745.229 Certification of individuals and firms engaged in lead-based paint activities... engaged in lead-based paint activities: public and commercial buildings, bridges and superstructures....

  16. 40 CFR 745.229 - Certification of individuals and firms engaged in lead-based paint activities: public and...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... SUBSTANCES CONTROL ACT LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Lead-Based Paint Activities § 745.229 Certification of individuals and firms engaged in lead-based paint activities... engaged in lead-based paint activities: public and commercial buildings, bridges and superstructures....

  17. 40 CFR 745.229 - Certification of individuals and firms engaged in lead-based paint activities: public and...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... SUBSTANCES CONTROL ACT LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Lead-Based Paint Activities § 745.229 Certification of individuals and firms engaged in lead-based paint activities... engaged in lead-based paint activities: public and commercial buildings, bridges and superstructures....

  18. 40 CFR 745.230 - Work practice standards for conducting lead-based paint activities: public and commercial...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... CONTROL ACT LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Lead-Based Paint Activities § 745.230 Work practice standards for conducting lead-based paint activities: public and... lead-based paint activities: public and commercial buildings, bridges and superstructures....

  19. 40 CFR 745.238 - Fees for accreditation and certification of lead-based paint activities.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... certification of lead-based paint activities. 745.238 Section 745.238 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN...-certification (every 3 years, see 40 CFR 745.226(f)(7) for details) Firm $550 $550 Combined Renovation and...

  20. 40 CFR 745.238 - Fees for accreditation and certification of lead-based paint activities.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... certification of lead-based paint activities. 745.238 Section 745.238 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN...-certification (every 3 years, see 40 CFR 745.226(f)(7) for details) Firm $550 $550 Combined Renovation and...

  1. 40 CFR 745.238 - Fees for accreditation and certification of lead-based paint activities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... certification of lead-based paint activities. 745.238 Section 745.238 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN...-certification (every 3 years, see 40 CFR 745.226(f)(7) for details) Firm $550 $550 Combined Renovation and...

  2. 40 CFR 745.238 - Fees for accreditation and certification of lead-based paint activities.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... certification of lead-based paint activities. 745.238 Section 745.238 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN...-certification (every 3 years, see 40 CFR 745.226(f)(7) for details) Firm $550 $550 Combined Renovation and...

  3. 24 CFR 242.81 - Lead-based paint poisoning prevention.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... AUTHORITIES MORTGAGE INSURANCE FOR HOSPITALS Miscellaneous Requirements § 242.81 Lead-based paint poisoning prevention. Requirements set forth in 24 CFR part 35 apply to this program. ... 24 Housing and Urban Development 2 2010-04-01 2010-04-01 false Lead-based paint...

  4. 24 CFR 200.77 - Lead-based paint poisoning prevention.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... Programs; and Continuing Eligibility Requirements for Existing Projects Property Requirements § 200.77 Lead-based paint poisoning prevention. Requirements set forth in 24 CFR part 35 apply to these programs. ... 24 Housing and Urban Development 2 2013-04-01 2013-04-01 false Lead-based paint...

  5. 24 CFR 242.81 - Lead-based paint poisoning prevention.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... AUTHORITIES MORTGAGE INSURANCE FOR HOSPITALS Miscellaneous Requirements § 242.81 Lead-based paint poisoning prevention. Requirements set forth in 24 CFR part 35 apply to this program. ... 24 Housing and Urban Development 2 2012-04-01 2012-04-01 false Lead-based paint...

  6. 24 CFR 200.77 - Lead-based paint poisoning prevention.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... Programs; and Continuing Eligibility Requirements for Existing Projects Property Requirements § 200.77 Lead-based paint poisoning prevention. Requirements set forth in 24 CFR part 35 apply to these programs. ... 24 Housing and Urban Development 2 2011-04-01 2011-04-01 false Lead-based paint...

  7. 24 CFR 200.77 - Lead-based paint poisoning prevention.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... Programs; and Continuing Eligibility Requirements for Existing Projects Property Requirements § 200.77 Lead-based paint poisoning prevention. Requirements set forth in 24 CFR part 35 apply to these programs. ... 24 Housing and Urban Development 2 2014-04-01 2014-04-01 false Lead-based paint...

  8. 24 CFR 242.81 - Lead-based paint poisoning prevention.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... AUTHORITIES MORTGAGE INSURANCE FOR HOSPITALS Miscellaneous Requirements § 242.81 Lead-based paint poisoning prevention. Requirements set forth in 24 CFR part 35 apply to this program. ... 24 Housing and Urban Development 2 2013-04-01 2013-04-01 false Lead-based paint...

  9. 24 CFR 200.77 - Lead-based paint poisoning prevention.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Programs; and Continuing Eligibility Requirements for Existing Projects Property Requirements § 200.77 Lead-based paint poisoning prevention. Requirements set forth in 24 CFR part 35 apply to these programs. ... 24 Housing and Urban Development 2 2010-04-01 2010-04-01 false Lead-based paint...

  10. 24 CFR 242.81 - Lead-based paint poisoning prevention.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... AUTHORITIES MORTGAGE INSURANCE FOR HOSPITALS Miscellaneous Requirements § 242.81 Lead-based paint poisoning prevention. Requirements set forth in 24 CFR part 35 apply to this program. ... 24 Housing and Urban Development 2 2014-04-01 2014-04-01 false Lead-based paint...

  11. 24 CFR 200.77 - Lead-based paint poisoning prevention.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... Programs; and Continuing Eligibility Requirements for Existing Projects Property Requirements § 200.77 Lead-based paint poisoning prevention. Requirements set forth in 24 CFR part 35 apply to these programs. ... 24 Housing and Urban Development 2 2012-04-01 2012-04-01 false Lead-based paint...

  12. 24 CFR 242.81 - Lead-based paint poisoning prevention.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... AUTHORITIES MORTGAGE INSURANCE FOR HOSPITALS Miscellaneous Requirements § 242.81 Lead-based paint poisoning prevention. Requirements set forth in 24 CFR part 35 apply to this program. ... 24 Housing and Urban Development 2 2011-04-01 2011-04-01 false Lead-based paint...

  13. The prevalence of lead-based paint hazards in U.S. housing.

    PubMed Central

    Jacobs, David E; Clickner, Robert P; Zhou, Joey Y; Viet, Susan M; Marker, David A; Rogers, John W; Zeldin, Darryl C; Broene, Pamela; Friedman, Warren

    2002-01-01

    In this study we estimated the number of housing units in the United States with lead-based paint and lead-based paint hazards. We included measurements of lead in intact and deteriorated paint, interior dust, and bare soil. A nationally representative, random sample of 831 housing units was evaluated in a survey between 1998 and 2000; the units and their occupants did not differ significantly from nationwide characteristics. Results indicate that 38 million housing units had lead-based paint, down from the 1990 estimate of 64 million. Twenty-four million had significant lead-based paint hazards. Of those with hazards, 1.2 million units housed low-income families (< 30,000 US dollars/year) with children under 6 years of age. Although 17% of government-supported, low-income housing had hazards, 35% of all low-income housing had hazards. For households with incomes greater than or equal to 30,000 US dollars/year, 19% had hazards. Fourteen percent of all houses had significantly deteriorated lead-based paint, and 16% and 7%, respectively, had dust lead and soil lead levels above current standards of the U.S. Department of Housing and Urban Development and the U.S. Environmental Protection Agency. The prevalence of lead-based paint and hazards increases with age of housing, but most painted surfaces, even in older housing, do not have lead-based paint. Between 2% and 25% of painted building components were coated with lead-based paint. Housing in the Northeast and Midwest had about twice the prevalence of hazards compared with housing in the South and West. The greatest risk occurs in older units with lead-based paint hazards that either will be or are currently occupied by families with children under 6 years of age and are low-income and/or are undergoing renovation or maintenance that disturbs lead-based paint. This study also confirms projections made in 2000 by the President's Task Force on Environmental Health Risks and Safety Risks to Children of the number of

  14. 7 CFR Exhibit H to Subpart A of... - Prohibition of Lead-Based Paints

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 12 2014-01-01 2013-01-01 true Prohibition of Lead-Based Paints H Exhibit H to... Other Development Pt. 1924, Subpt. A, Exh. H Exhibit H to Subpart A of Part 1924—Prohibition of Lead... of the Lead-Based Paint Poisoning Prevention Act, Public Law 91-695, as amended, (42 U.S.C. 4801...

  15. 7 CFR Exhibit H to Subpart A of... - Prohibition of Lead-Based Paints

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 12 2013-01-01 2013-01-01 false Prohibition of Lead-Based Paints H Exhibit H to... Other Development Pt. 1924, Subpt. A, Exh. H Exhibit H to Subpart A of Part 1924—Prohibition of Lead... of the Lead-Based Paint Poisoning Prevention Act, Public Law 91-695, as amended, (42 U.S.C. 4801...

  16. 7 CFR Exhibit H to Subpart A of... - Prohibition of Lead-Based Paints

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 12 2010-01-01 2010-01-01 false Prohibition of Lead-Based Paints H Exhibit H to... Other Development Pt. 1924, Subpt. A, Exh. H Exhibit H to Subpart A of Part 1924—Prohibition of Lead... of the Lead-Based Paint Poisoning Prevention Act, Public Law 91-695, as amended, (42 U.S.C. 4801...

  17. 7 CFR Exhibit H to Subpart A of... - Prohibition of Lead-Based Paints

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 12 2012-01-01 2012-01-01 false Prohibition of Lead-Based Paints H Exhibit H to... Other Development Pt. 1924, Subpt. A, Exh. H Exhibit H to Subpart A of Part 1924—Prohibition of Lead... of the Lead-Based Paint Poisoning Prevention Act, Public Law 91-695, as amended, (42 U.S.C. 4801...

  18. 7 CFR Exhibit H to Subpart A of... - Prohibition of Lead-Based Paints

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 12 2011-01-01 2011-01-01 false Prohibition of Lead-Based Paints H Exhibit H to... Other Development Pt. 1924, Subpt. A, Exh. H Exhibit H to Subpart A of Part 1924—Prohibition of Lead... of the Lead-Based Paint Poisoning Prevention Act, Public Law 91-695, as amended, (42 U.S.C. 4801...

  19. FIELD DEMONSTRATION OF LEAD-BASED PAINT REMOVAL AND INORGANIC STABILIZATION TECHNOLOGIES

    EPA Science Inventory

    A study was conducted to demonstrate the effectiveness of a wet abrasive blasting technology to remove lead-based paint from exterior wood siding and brock substrates and to stabilize the resultant blasting media (coal slag and mineral sand) paint debris to reduce the leachable l...

  20. 24 CFR 1000.40 - Do lead-based paint poisoning prevention requirements apply to affordable housing activities...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 24 Housing and Urban Development 4 2011-04-01 2011-04-01 false Do lead-based paint poisoning... AMERICAN HOUSING ACTIVITIES General § 1000.40 Do lead-based paint poisoning prevention requirements apply..., subparts A, B, H, J, K, M and R of this title, which implement the Lead-Based Paint Poisoning...

  1. 24 CFR 1000.40 - Do lead-based paint poisoning prevention requirements apply to affordable housing activities...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 4 2010-04-01 2010-04-01 false Do lead-based paint poisoning... AMERICAN HOUSING ACTIVITIES General § 1000.40 Do lead-based paint poisoning prevention requirements apply..., subparts A, B, H, J, K, M and R of this title, which implement the Lead-Based Paint Poisoning...

  2. 24 CFR 1000.40 - Do lead-based paint poisoning prevention requirements apply to affordable housing activities...

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 24 Housing and Urban Development 4 2012-04-01 2012-04-01 false Do lead-based paint poisoning... AMERICAN HOUSING ACTIVITIES General § 1000.40 Do lead-based paint poisoning prevention requirements apply..., subparts A, B, H, J, K, M and R of this title, which implement the Lead-Based Paint Poisoning...

  3. 24 CFR 1000.40 - Do lead-based paint poisoning prevention requirements apply to affordable housing activities...

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 24 Housing and Urban Development 4 2013-04-01 2013-04-01 false Do lead-based paint poisoning... AMERICAN HOUSING ACTIVITIES General § 1000.40 Do lead-based paint poisoning prevention requirements apply..., subparts A, B, H, J, K, M and R of this title, which implement the Lead-Based Paint Poisoning...

  4. 24 CFR 1000.40 - Do lead-based paint poisoning prevention requirements apply to affordable housing activities...

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 24 Housing and Urban Development 4 2014-04-01 2014-04-01 false Do lead-based paint poisoning... AMERICAN HOUSING ACTIVITIES General § 1000.40 Do lead-based paint poisoning prevention requirements apply..., subparts A, B, H, J, K, M and R of this title, which implement the Lead-Based Paint Poisoning...

  5. 24 CFR 35.1355 - Ongoing lead-based paint maintenance and reevaluation activities.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... Secretary, Department of Housing and Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN... CFR 745.227(d)(8)-(11), but only if the soil lead levels have not been previously measured. (C) The... 24 Housing and Urban Development 1 2012-04-01 2012-04-01 false Ongoing lead-based...

  6. 24 CFR 35.1355 - Ongoing lead-based paint maintenance and reevaluation activities.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Secretary, Department of Housing and Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN... CFR 745.227(d)(8)-(11), but only if the soil lead levels have not been previously measured. (C) The... 24 Housing and Urban Development 1 2010-04-01 2010-04-01 false Ongoing lead-based...

  7. 24 CFR 35.1355 - Ongoing lead-based paint maintenance and reevaluation activities.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... Secretary, Department of Housing and Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN... CFR 745.227(d)(8)-(11), but only if the soil lead levels have not been previously measured. (C) The... 24 Housing and Urban Development 1 2011-04-01 2011-04-01 false Ongoing lead-based...

  8. 24 CFR 35.1355 - Ongoing lead-based paint maintenance and reevaluation activities.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... Secretary, Department of Housing and Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN... CFR 745.227(d)(8)-(11), but only if the soil lead levels have not been previously measured. (C) The... 24 Housing and Urban Development 1 2013-04-01 2013-04-01 false Ongoing lead-based...

  9. 24 CFR 30.65 - Failure to disclose lead-based paint hazards.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 24 Housing and Urban Development 1 2011-04-01 2011-04-01 false Failure to disclose lead-based... to disclose lead-based paint hazards. (a) General. The Director of the Office of Healthy Homes and Lead Hazard Control, or his or her designee, may initiate a civil money penalty action against...

  10. 24 CFR 30.65 - Failure to disclose lead-based paint hazards.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 24 Housing and Urban Development 1 2014-04-01 2014-04-01 false Failure to disclose lead-based... to disclose lead-based paint hazards. (a) General. The Director of the Office of Healthy Homes and Lead Hazard Control, or his or her designee, may initiate a civil money penalty action against...

  11. 24 CFR 30.65 - Failure to disclose lead-based paint hazards.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 24 Housing and Urban Development 1 2012-04-01 2012-04-01 false Failure to disclose lead-based... to disclose lead-based paint hazards. (a) General. The Director of the Office of Healthy Homes and Lead Hazard Control, or his or her designee, may initiate a civil money penalty action against...

  12. 24 CFR 30.65 - Failure to disclose lead-based paint hazards.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 1 2010-04-01 2010-04-01 false Failure to disclose lead-based... to disclose lead-based paint hazards. (a) General. The Director of the Office of Healthy Homes and Lead Hazard Control, or his or her designee, may initiate a civil money penalty action against...

  13. 24 CFR 30.65 - Failure to disclose lead-based paint hazards.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 24 Housing and Urban Development 1 2013-04-01 2013-04-01 false Failure to disclose lead-based... to disclose lead-based paint hazards. (a) General. The Director of the Office of Healthy Homes and Lead Hazard Control, or his or her designee, may initiate a civil money penalty action against...

  14. REMOVAL AND CONTAINMENT OF LEAD-BASED PAINT VIA NEEDLE SCALERS

    EPA Science Inventory

    This report describes a comparative technical and economic evaluation of using a dustless needlegun system versus a conventional abrasive grit blasting system in the removal of lead-based paint from steel structures. The objective of the study was to comparatively analyze the ope...

  15. 40 CFR 745.327 - State or Indian Tribal lead-based paint compliance and enforcement programs.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT LEAD-BASED PAINT POISONING PREVENTION... the requirements of 40 CFR part 3—(Electronic reporting) are satisfied in their lead-based paint... 40 Protection of Environment 31 2014-07-01 2014-07-01 false State or Indian Tribal...

  16. 40 CFR 745.327 - State or Indian Tribal lead-based paint compliance and enforcement programs.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT LEAD-BASED PAINT POISONING PREVENTION... the requirements of 40 CFR part 3—(Electronic reporting) are satisfied in their lead-based paint... 40 Protection of Environment 32 2013-07-01 2013-07-01 false State or Indian Tribal...

  17. 40 CFR 745.327 - State or Indian Tribal lead-based paint compliance and enforcement programs.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT LEAD-BASED PAINT POISONING PREVENTION... the requirements of 40 CFR part 3—(Electronic reporting) are satisfied in their lead-based paint... 40 Protection of Environment 32 2012-07-01 2012-07-01 false State or Indian Tribal...

  18. 75 FR 21660 - Notice of Lodging of Consent Decree Under the Residential Lead-Based Paint Hazard Reduction Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-26

    ... of Lodging of Consent Decree Under the Residential Lead- Based Paint Hazard Reduction Act Notice is... (``HUD'') under the Residential Lead-Based Paint Hazard Reduction Act, 42 U.S.C. 4851 et seq. (``Lead... Lead Hazard Reduction Act. Under the Consent Decree, the Defendant will certify that it is...

  19. 77 FR 22612 - Notice of Lodging of Consent Decree Under the Residential Lead-Based Paint Hazard Reduction Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-16

    ... of Lodging of Consent Decree Under the Residential Lead- Based Paint Hazard Reduction Act Notice is... Urban Development (``HUD'') under the Residential Lead- Based Paint Hazard Reduction Act, 42 U.S.C. 4851 et seq. (``Lead Hazard Reduction Act.'') The United States alleged in the complaint that...

  20. 75 FR 76754 - Notice of Lodging of Consent Decree Under the Residential Lead-Based Paint Hazard Reduction Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-09

    ... of Lodging of Consent Decree Under the Residential Lead- Based Paint Hazard Reduction Act Notice is... Urban Development (``HUD'') under the Residential Lead- Based Paint Hazard Reduction Act, 42 U.S.C. 4851 et seq. (``Lead Hazard Reduction Act''). The United States alleged in the complaint that...

  1. 78 FR 38730 - Announcement of Funding Awards for Lead-Based Paint Hazard Control, and Lead Hazard Reduction...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-27

    ... Lead Based Paint Hazard Control and the Lead Hazard Reduction Demonstration Programs (FR-5700-N-04... URBAN DEVELOPMENT Announcement of Funding Awards for Lead-Based Paint Hazard Control, and Lead Hazard Reduction Demonstration Grant Programs for Fiscal Year (FY) 2013 AGENCY: Office of Healthy Homes and...

  2. 77 FR 70179 - Requirements for Lead-Based Paint Hazards in Federally Owned Residential Properties and Housing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-23

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT Requirements for Lead-Based Paint Hazards in Federally Owned Residential Properties...: Requirements for Lead-Based Paint Hazards in Federally Owned Residential Properties and Housing...

  3. 75 FR 159 - Notice of Lodging of Consent Decree Under the Residential Lead-Based Paint Hazard Reduction Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-04

    ... of Lodging of Consent Decree Under the Residential Lead- Based Paint Hazard Reduction Act Notice is.... EPA'') and the Department of Housing and Urban Development (``HUD'') under the Residential Lead-Based Paint Hazard Reduction Act, 42 U.S.C. 4851 et seq. (``Lead Hazard Reduction Act''). The United...

  4. 40 CFR 745.327 - State or Indian Tribal lead-based paint compliance and enforcement programs.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT LEAD-BASED PAINT POISONING PREVENTION... ensure that the requirements of 40 CFR part 3—(Electronic reporting) are satisfied in their lead-based... 40 Protection of Environment 31 2011-07-01 2011-07-01 false State or Indian Tribal...

  5. 40 CFR 745.327 - State or Indian Tribal lead-based paint compliance and enforcement programs.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT LEAD-BASED PAINT POISONING PREVENTION... ensure that the requirements of 40 CFR part 3—(Electronic reporting) are satisfied in their lead-based... 40 Protection of Environment 30 2010-07-01 2010-07-01 false State or Indian Tribal...

  6. In situ vitrification and removal of lead-based paint for steel structures

    SciTech Connect

    Covey, S.; Lattimore, L.; Kumar, A.

    1995-12-31

    The feasibility of in-situ vitrification of lead oxide contained in red lead based organic coatings was investigated. The removal of organic lead-based primers and paints has been achieved by a flame spray process that uses a glass/ceramic compound designed for high lead solubility and resistance to devitrification. The glass/ceramic compounds were prepared by fusing, fritting, and ball milling to produce the desired powder. The result powder was collected and used to flame spray previously prepared samples containing a commonly used red lead primer. Oxyacetylene flame spray technology was used to apply the glass compound to the steel substrate. The resulting glass waste was collected and analyzed for lead content using Energy Dispersive Spectroscopy (EDS) and X-Ray Diffraction analysis. The lead cation leachability rates were determined by the US Environmental Protection Agency (EPA) approved Toxicity Characteristic Leaching Procedure (TCLP). The designer glass waste form that exhibited the best results was a borosilicate glass with iron oxide additions. The iron silicate glass waste form leached approximately 1 ppm of lead during the TCLP, far below the current 5 ppm limit for hazardous waste.

  7. Evaluation of two lead-based paint removal and waste stabilization technology combinations on typical exterior surfaces.

    PubMed

    Daniels, A E; Kominsky, J R; Clark, P J

    2001-10-12

    A study was conducted to demonstrate the effectiveness of a wet abrasive blasting technology to remove lead-based paint from exterior wood siding and brick substrates as well as to evaluate the effectiveness of two waste stabilization technologies to stabilize the resulting blast media (coal slag and mineral sand) paint debris thereby reducing the leachable lead content. The lead-based paint removal technology effectiveness was determined by the use of an X-ray fluorescence (XRF) spectrum analyzer (L- and K-shell). The effectiveness of the technologies to stabilize the debris was evaluated through the toxicity characteristic leaching procedure (TCLP). Wet abrasive blasting effectively removed the lead-based paint coating from both the wood and brick substrates to below the US Department of Housing and Urban Development Guideline (1mg/cm(2)) with no minimal or no damage to the underlying substrates (P<0.0001). The mean area air levels of lead-containing particulate generated during paint removal were significantly below the personal exposure limit (PEL) (P<0.0001). However, the mean personal breathing zone lead levels were approximately three times higher than the PEL. Neither of the two stabilization technologies consistently stabilized the resultant paint debris to achieve a leachable lead content below the RCRA regulatory threshold of <5 mg/l.

  8. Thermal spray removal of lead-based paint from the viaduct bridge at Rock Island Arsenal, IL. Final report

    SciTech Connect

    Boy, J.H.; Weber, R.A.; Kumar, A.

    1998-06-01

    This report documents a field demonstration at the Rock Island Arsenal, IL, that validated the thermal spray vitrification (TSV) process as a safe and effective technique for removing lead-based paint from a steel bridge. Specially formulated glass was applied in a molten state to painted steel using a conventional thermal spray application system. The molten glass reacts with the paint, and encapsulates the lead. The cooled glass readily cracks and falls off, removing the paint. After onsite remelting of the glass waste to complete the encapsulation process, the final waste product is chemically inert and may be disposed of in a regular landfill. The Illinois Environmental Protection Agency, Division of Air Pollution Control determined that the glass remelt process could be considered a paint-removal operation for which no air quality permit was required.

  9. The leaching of lead from lead-based paint in landfill environments.

    PubMed

    Wadanambi, Lakmini; Dubey, Brajesh; Townsend, Timothy

    2008-08-30

    Lead leaching from lead-based paint (LBP) was examined using standardized laboratory protocols and tests with leachate from actual and simulated landfill environments. Two different LBP samples were tested; leaching solutions included leachates from three municipal solid waste (MSW) landfills and three construction and demolition (C&D) debris landfills. The toxicity characteristic leaching procedure (TCLP) and the synthetic precipitation leaching procedure (SPLP) were also performed. Lead concentrations were many times higher using the TCLP compared to the SPLP and the landfill leachates. No significant difference (alpha=0.05) was observed in leached lead concentrations from the MSW landfill and C&D debris landfill leachates. The impact of other building materials present in LBP debris on lead leaching was examined by testing mixtures of LBP (2%) and different building materials (98%; steel, wood, drywall, concrete). The type of substrate present impacted lead leaching results, with concrete demonstrating the most dramatic impact; the lowest lead concentrations were measured in the presence of concrete under both TCLP and SPLP extractions. PMID:18276069

  10. The leaching of lead from lead-based paint in landfill environments.

    PubMed

    Wadanambi, Lakmini; Dubey, Brajesh; Townsend, Timothy

    2008-08-30

    Lead leaching from lead-based paint (LBP) was examined using standardized laboratory protocols and tests with leachate from actual and simulated landfill environments. Two different LBP samples were tested; leaching solutions included leachates from three municipal solid waste (MSW) landfills and three construction and demolition (C&D) debris landfills. The toxicity characteristic leaching procedure (TCLP) and the synthetic precipitation leaching procedure (SPLP) were also performed. Lead concentrations were many times higher using the TCLP compared to the SPLP and the landfill leachates. No significant difference (alpha=0.05) was observed in leached lead concentrations from the MSW landfill and C&D debris landfill leachates. The impact of other building materials present in LBP debris on lead leaching was examined by testing mixtures of LBP (2%) and different building materials (98%; steel, wood, drywall, concrete). The type of substrate present impacted lead leaching results, with concrete demonstrating the most dramatic impact; the lowest lead concentrations were measured in the presence of concrete under both TCLP and SPLP extractions.

  11. EVALUATION OF TWO LEAD-BASED PAINT REMOVAL AND WASTE STABILIZATION TECHNOLOGY COMBINATIONS ON TYPICAL EXTERIOR SURFACES

    EPA Science Inventory

    A study was conducted to demonstrate the effectiveness of a wet abrasive blasting technology to remove lead-based paint from exterior wood siding and brick substrates as well as to evaluate the effectiveness of two waste stabilization technologies to stabilize the resulting blast...

  12. 40 CFR 745.227 - Work practice standards for conducting lead-based paint activities: target housing and child...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Lead-Based Paint, Lead-Contaminated Dust, and Lead-Contaminated Soil; the EPA Residential Sampling for Lead: Protocols for Dust and Soil Sampling (EPA report number 7474-R-95-001); Regulations, guidance... Contaminiated Soil or other equivalent guidelines. (b) Inspection. (1) An inspection shall be conducted only...

  13. 40 CFR 745.227 - Work practice standards for conducting lead-based paint activities: target housing and child...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Lead-Based Paint, Lead-Contaminated Dust, and Lead-Contaminated Soil; the EPA Residential Sampling for Lead: Protocols for Dust and Soil Sampling (EPA report number 7474-R-95-001); Regulations, guidance... Contaminiated Soil or other equivalent guidelines. (b) Inspection. (1) An inspection shall be conducted only...

  14. 40 CFR 745.227 - Work practice standards for conducting lead-based paint activities: target housing and child...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Lead-Based Paint, Lead-Contaminated Dust, and Lead-Contaminated Soil; the EPA Residential Sampling for Lead: Protocols for Dust and Soil Sampling (EPA report number 7474-R-95-001); Regulations, guidance... Contaminiated Soil or other equivalent guidelines. (b) Inspection. (1) An inspection shall be conducted only...

  15. 40 CFR 745.227 - Work practice standards for conducting lead-based paint activities: target housing and child...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Lead-Based Paint, Lead-Contaminated Dust, and Lead-Contaminated Soil; the EPA Residential Sampling for Lead: Protocols for Dust and Soil Sampling (EPA report number 7474-R-95-001); Regulations, guidance... Contaminiated Soil or other equivalent guidelines. (b) Inspection. (1) An inspection shall be conducted only...

  16. 40 CFR 745.227 - Work practice standards for conducting lead-based paint activities: target housing and child...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Lead-Based Paint, Lead-Contaminated Dust, and Lead-Contaminated Soil; the EPA Residential Sampling for Lead: Protocols for Dust and Soil Sampling (EPA report number 7474-R-95-001); Regulations, guidance... Contaminiated Soil or other equivalent guidelines. (b) Inspection. (1) An inspection shall be conducted only...

  17. 75 FR 58423 - Notice of Funding Availability for HUD's Fiscal Year (FY) 2010 Lead-Based Paint Hazard Control...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-24

    ... URBAN DEVELOPMENT Notice of Funding Availability for HUD's Fiscal Year (FY) 2010 Lead-Based Paint Hazard Control Grant Program and Lead Hazard Reduction Demonstration Grant Program; Technical Correction AGENCY: Office of Healthy Homes and Lead Hazard Control, HUD. ACTION: Notice of technical correction. SUMMARY:...

  18. Lead-based paint in dwellings: The potential for contamination of the home environment during renovation.

    PubMed

    Inskip, M J; Hutton, M

    1987-12-01

    The quantity and particle size characteristics of lead in dust released during three different paint removal techniques was determined under controlled conditions and in situ in a dwelling. Air-lead and deposited dust-lead levels were highest after sanding but 'burning-off' and 'hot-air' removal methods also produced significant contamination. The importance of dust particle-size and lead is discussed in relation to the potential hazard to home renovators via inhalation and to children via the 'hand-to-mouth' route.

  19. Lead abatement training for supervisors and contractors. Instructors guide

    SciTech Connect

    Not Available

    1999-01-01

    This training program is designed to be a 32 hour training course, and is intended for individuals supervising residential lead abatement projects. The course is designed to meet the requirements of 40 CFR Part 745-Lead. Requirements for Lead-Based Paint Activities in Target Housing and Child Occupied Facilities, a federal regulation under section 402 of the Toxic Substance Control Act (TSCA). Topics covered in the course include; the history of lead; health effects; legal and insurance consideration; regulations overview; inspection and risk assessment; report interpretation; development and implementation of occupant protection plans; paint hazard recognition and materials identification; XRF testing/sampling and abatement methods.

  20. 24 CFR 35.140 - Prohibited methods of paint removal.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... and Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES General Lead-Based Paint Requirements and Definitions for All Programs. § 35.140 Prohibited methods of paint removal. The following methods shall not be used to remove paint that is, or may be, lead-based paint:...

  1. Addressing Lead-Based Paint Hazards During Renovation, Remodeling, and Rehabilitation in Federally Owned and Assisted Housing. Student Manual for Use in HUD-Sponsored Lead-Safe Work Practices Training.

    ERIC Educational Resources Information Center

    Department of Housing and Urban Development, Washington, DC.

    This student manual comprises the United States Environmental Protection Agency's model renovation training course designed for renovation, remodeling, and painting contractors. It provides information regarding the containment, minimization, and cleanup of lead hazards during activities that disturb lead painted surfaces. Introductory material…

  2. 75 FR 54899 - Notice of Availability: Notice of Funding Availability for HUD's Fiscal Year (FY) 2010 Lead-Based...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-09

    ... Lead-Based Paint Hazard Control Grant Program and Lead Hazard Reduction Demonstration Grant Program... requirements for the FY2010 Lead-Based Paint Hazard Control Grant Program and Lead Hazard Reduction... government undertake comprehensive programs to identify and control lead-based paint hazards in...

  3. Noise Abatement

    NASA Astrophysics Data System (ADS)

    1983-01-01

    SMART, Sound Modification and Regulated Temperature compound, is a liquid plastic mixture with exceptional energy and sound absorbing qualities. It is derived from a very elastic plastic which was an effective noise abatement material in the Apollo Guidance System. Discovered by a NASA employee, it is marketed by Environmental Health Systems, Inc. (EHS). The product has been successfully employed by a diaper company with noisy dryers and a sugar company with noisy blowers. The company also manufactures an audiometric test booth and acoustical office partitions.

  4. 24 CFR 35.1325 - Abatement.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... Housing and Urban Development Office of the Secretary, Department of Housing and Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Methods and Standards for Lead-Paint... authorized by EPA, or by EPA at 40 CFR 745.227(e), and shall be completed by achieving clearance...

  5. 24 CFR 35.1325 - Abatement.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... Housing and Urban Development Office of the Secretary, Department of Housing and Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Methods and Standards for Lead-Paint... authorized by EPA, or by EPA at 40 CFR 745.227(e), and shall be completed by achieving clearance...

  6. 24 CFR 35.1325 - Abatement.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... Housing and Urban Development Office of the Secretary, Department of Housing and Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Methods and Standards for Lead-Paint... authorized by EPA, or by EPA at 40 CFR 745.227(e), and shall be completed by achieving clearance...

  7. 24 CFR 35.1325 - Abatement.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... Housing and Urban Development Office of the Secretary, Department of Housing and Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Methods and Standards for Lead-Paint... authorized by EPA, or by EPA at 40 CFR 745.227(e), and shall be completed by achieving clearance...

  8. 24 CFR 35.1325 - Abatement.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Housing and Urban Development Office of the Secretary, Department of Housing and Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Methods and Standards for Lead-Paint... authorized by EPA, or by EPA at 40 CFR 745.227(e), and shall be completed by achieving clearance...

  9. 24 CFR 35.135 - Use of paint containing lead.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 24 Housing and Urban Development 1 2013-04-01 2013-04-01 false Use of paint containing lead. 35... Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES General Lead-Based Paint Requirements and Definitions for All Programs. § 35.135 Use of paint containing lead....

  10. 24 CFR 35.135 - Use of paint containing lead.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 24 Housing and Urban Development 1 2014-04-01 2014-04-01 false Use of paint containing lead. 35... Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES General Lead-Based Paint Requirements and Definitions for All Programs. § 35.135 Use of paint containing lead....

  11. 24 CFR 35.135 - Use of paint containing lead.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 24 Housing and Urban Development 1 2011-04-01 2011-04-01 false Use of paint containing lead. 35... Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES General Lead-Based Paint Requirements and Definitions for All Programs. § 35.135 Use of paint containing lead....

  12. 24 CFR 35.135 - Use of paint containing lead.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 1 2010-04-01 2010-04-01 false Use of paint containing lead. 35... Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES General Lead-Based Paint Requirements and Definitions for All Programs. § 35.135 Use of paint containing lead....

  13. 24 CFR 35.135 - Use of paint containing lead.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 24 Housing and Urban Development 1 2012-04-01 2012-04-01 false Use of paint containing lead. 35... Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES General Lead-Based Paint Requirements and Definitions for All Programs. § 35.135 Use of paint containing lead....

  14. An evaluation of chemical screening test kits for lead in paint

    SciTech Connect

    Oglesby, L.S.

    1996-04-01

    The Residential Lead-Based Paint Hazard Reduction Act (Title X) requires abatement and management of lead-based paint. The purpose of this study was to evaluate three chemical screening test kits using materials and methods from one study and subjecting the results to the statistical analysis of another. The three kits were used to predict the presence of lead in paint at ten weight concentrations from 0.04 to 3.97%. Paint was applied to four wood boards yielding a sample size of 40. Four boards were painted with lead-free paint and used as blanks. All of the boards were tested with the three test kits by an untrained individual having no knowledge of the actual lead content. Sensitivity, specificity, and false positive and negative rates were calculated for the test kit results. The manufactures` detection limits, the observed sensitivity ranged from 1.00 to 0.80, specificity ranged from 1.00 to 0.42, false positive ranged from 0 to 58%, and false negatives ranged from 0 to 20%. At the 0.5% Federal threshold level, the observed sensitivity ranged from 1.00 to 0.94, specificity ranged from 1.00 to 0.5, false positives ranged from 0 to 11.1%, and false negatives ranged from 0 to 20%. The observed false positive and false negative rates for all three kits were found to be significantly lower than those reported in a previous study. These results indicate that the kits perform very well at the Federal threshold, with two of the kits having false negative rates below 12.5% and false positive rates of 3.13%. These results indicate that these two kits would probably be acceptable screening tests for lead in paint.

  15. Efficacy of the Community Reinvestment Act in promoting lead abatement.

    PubMed

    Yiin, Lih-Ming; Weber, John; Sannoh, Sulaiman; Rhoads, George

    2005-04-01

    The efficacy of the Community Reinvestment Act (CRA) in assisting homeowners or landlords in urban areas of New Jersey to finance lead abatement was evaluated in the study reported here, as was the effectiveness of the abatement. The study involved working with homeowners, banks, local health departments, and communities to facilitate financing for lead abatement, and collecting environmental-dust specimens from some of the participants' homes before and after abatement. Of the 113 interested subjects, 59 (52 percent) completed abatement of their homes. Of the 58 who applied for CRA loans, 21 received approvals and had the work completed. Thirty-nine of the homeowners found alternate means of financing abatement. The environmental data showed a significant decrease on the windowsills in the 4aated homes, but not on the floors. In conclusion, one-on-one counseling of homeowners about funding was associated with more than 50 percent success in completing abatement, The CRA loans' accounted for about one-third of the abated units. The lead abatement was effective in removing lead paint from the windows, but not in reducing dust lead levels on the floors. PMID:15856664

  16. Insect abatement system

    NASA Technical Reports Server (NTRS)

    Spiro, Clifford Lawrence (Inventor); Burnell, Timothy Brydon (Inventor); Wengrovius, Jeffrey Hayward (Inventor)

    1997-01-01

    An insect abatement system prevents adhesion of insect debris to surfaces which must be kept substantially free of insect debris. An article is coated with an insect abatement coating comprising polyorganosiloxane with a Shore A hardness of less than 50 and a tensile strength of less than 4 MPa. A method for preventing the adhesion of insect debris to surfaces includes the step of applying an insect abatement coating to a surface which must be kept substantially free of insect debris.

  17. 40 CFR 745.65 - Lead-based paint hazards.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... by EPA at 40 CFR part 745, subpart L and in regulations issued by the Department of Housing and Urban Development (HUD) at 24 CFR part 35, subpart R. The work practice standards in those regulations do not apply... interior window sills based on wipe samples. (c) Soil-lead hazard. A soil-lead hazard is bare soil...

  18. Reformulating Lead-Based Paint as a Problem in Canada

    PubMed Central

    Perron, Amélie

    2011-01-01

    Leaded gasoline was officially removed from the Canadian market in December 1990. The removal of a major lead source and the subsequent decline in children's blood lead levels marked an important transition point and sparked the emergence of new discourse on lead in Canada. Today, childhood lead poisoning is viewed as a problem of the past or a problem of the United States. Sparse Canadian surveillance data supported this view. Moreover, tensions among federal agencies evolved into a power struggle, with Health Canada ultimately becoming the dominant authority, thereby relegating important research initiatives to obscurity and also shaping a vastly weaker regulatory response to lead than occurred in the United States. PMID:21836119

  19. ESTE Project Brief: Environmental and Sustainable Technology Evaluations (ESTE): Verification of Qualitative Spot Test Kits for Lead in Paint

    EPA Science Inventory

    On April 22, 2008, EPA issued the final Lead; Renovation, Repair, and Painting (RRP) Program Rule. The rule addresses lead-based paint hazards created by renovation, repair, and painting activities that disturb lead-based paint in target housing and child-occupied facilities. Und...

  20. Noise Abatement Materials

    NASA Technical Reports Server (NTRS)

    1986-01-01

    A former NASA employee who discovered a kind of plastic that soaked up energy, dampened vibrations, and was a good noise abatement material, founded a company to market noise deadening adhesives, sheets, panels and enclosures. Known as SMART products, they are 75-80% lighter than ordinary soundproofing material and have demonstrated a high degree of effectiveness. The company, Varian Associates, makes enclosures for high voltage terminals and other electronic system components, and easily transportable audiometric test booths.

  1. Painted Pickup.

    ERIC Educational Resources Information Center

    Wheeler, Kimberly

    2001-01-01

    Discusses a six week art class project for elementary school children that lasted for six weeks. Explains that the students painted sunflowers in the style of Vincent van Gogh over the rust spots of a pickup truck. Reports that the painting served as great publicity for the art classes. (CMK)

  2. Monster Paintings

    ERIC Educational Resources Information Center

    Huggler, Silvia

    2010-01-01

    In this article, the author describes a unit on monsters wherein students were charged with painting an imaginary character and, in so doing, demonstrated mastery of expression, organization of space, control of paint media, and application of the elements of art. Students discovered how color and line could be used to convey expression. The media…

  3. Face Painting.

    ERIC Educational Resources Information Center

    Brooks, Diana

    1995-01-01

    Discusses the use of face painting as a technique for making the endangered species issue tangible for children while addressing the complexity of the issue. Children are "given" an animal of their own and are educated about the animal while having their faces painted to resemble the animal. (LZ)

  4. Painted Rhythms.

    ERIC Educational Resources Information Center

    Bastian, Duane

    1985-01-01

    In this art activity gifted students, ages 10 to 13, learn about internal and external rhythms and make a painting of an internal rhythm. The lesson can be expanded with a discussion of Kandinsky, Pollock, and other painters who have painted sound or have demonstrated rhythms. (RM)

  5. Evaluating paint-sludge chars for adsorption of selected paint solvents

    SciTech Connect

    Kim, B.R.; Kalis, E.M.; Salmeen, I.T.; Kruse, C.W.; Demir, I.; Rostam-Abadi, M.; Carlson, S.L.

    1996-06-01

    At Ford, a study had been carried out to investigate the technical feasibility of converting paint sludge to activated char and reusing the char in paint spray-booth water to capture paint solvents from spray-booth air. As part of the study, several chars were made from a paint sludge and six dried paints to evaluate their effectiveness as adsorbents by conducting a series of liquid-phase adsorption experiments. Three commonly-used paint solvents and p-nitrophenol were selected as adsorbates. The three paint solvents were toluene, 2-methyl-1-propanol (iso-butanol), and 2-butoxyethanol (butylcellosolve). In this paper, the results of the pyrolysis and adsorption experiments are presented along with practical implications. The primary findings include the following: (1) Black-paint chars showed substantially larger surface area and higher adsorption capacity (based on total weight) than white-paint chars which had high ash contents due to the white pigment, titanium dioxide; (2) the adsorption capacity of the paint-sludge char was between those of black-paint and white-paint chars, and was 5--20% that of a commercial activated carbon; (3) titanium dioxide in white-paint chars did not improve the chars` affinity for hydrophilic compounds such as 2-methyl-1-propanol and 2-butoxyethanol; (4) coal could be added to paint sludge to improve the quality of the resulting char and to reduce ash content; and (5) the pyrolysis of paint sludge could present an attractive opportunity for reusing and recycling a waste product for pollution abatement and as a vehicle component.

  6. Emission Abatement System

    DOEpatents

    Bromberg, Leslie; Cohn, Daniel R.; Rabinovich, Alexander

    2003-05-13

    Emission abatement system. The system includes a source of emissions and a catalyst for receiving the emissions. Suitable catalysts are absorber catalysts and selective catalytic reduction catalysts. A plasma fuel converter generates a reducing gas from a fuel source and is connected to deliver the reducing gas into contact with the absorber catalyst for regenerating the catalyst. A preferred reducing gas is a hydrogen rich gas and a preferred plasma fuel converter is a plasmatron. It is also preferred that the absorber catalyst be adapted for absorbing NO.sub.x.

  7. IPMC paints

    NASA Astrophysics Data System (ADS)

    Park, Il-Seok; Tiwari, Rashi; Kim, Kwang J.

    2008-03-01

    In this paper we are reporting a newely developed IPMC fabrication method, "IPMC Paint", which can be directly sprayed onto any complex surface. In order to fabricate the IPMC paint, liquid Nafion TM was used for the ionic conducting polymer instead of the typical film/sheet type Nafion TM. The viscosity of liquid Nafion TM was adjusted by adding Polyvinylpyrrolidone (PVP) to perform spray painting. Modified Nafion was sprayed onto the conducting substrate, Polyfoil TM which acts as base electrode layer. After three times spraying, ionic polymer layer has 45 μm thickness and 10 μm of surface roughness. Sensing tests show that IPMC paint sensor has more sensitivity (+/- 0.06 of producing voltage) than that of the typical IPMC (+/- 0.005 of producing voltage) when dynamic bending with 10 Hz frequency and 1.3 cm of displacement is applied to.

  8. Space Paint

    NASA Technical Reports Server (NTRS)

    1976-01-01

    Developed at Goddard, this improved inorganic paint may help protect coastal bridges subject to extreme corrosion from seawater spray. Potassium silicate formulated into a thin waterbase binder that sprays easily, adheres readily, and can be heavily loaded with zinc particles to provide uniform coverage in a single coat. Stanford Research Institute has measured an annual market in excess of $2 billion in painting highway bridges, utility pipelines, nuclear reactors, and railcar hoppers. Other suitable markets include offshore drilling facilities, railroad bridges, and ships.

  9. Biological abatement of cellulase inhibitors

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Bio-abatement uses a fungus to metabolize and remove fermentation inhibitors. To determine whether bio-abatement could alleviate enzyme inhibitor effects observed in biomass liquors after pretreatment, corn stover at 10% (w/v) solids was pretreated with either dilute acid or liquid hot water. The ...

  10. Paint and Pregnancy

    MedlinePlus

    ... are many other mixtures of paints used for industry, the arts, and hobbies. Years ago, lead and mercury were used in paint. How would I be exposed to the chemicals in paint? Exposure to paint can happen by: ...

  11. Dye Painting!

    ERIC Educational Resources Information Center

    Johnston, Ann

    This resource provides practical instructions for applying color and design directly to fabric. Basic information about the dye painting process is given. The guide addresses the technical aspects of fabric dye and color use and offers suggestions for fabric manipulation and dye application in order to achieve various design effects. This…

  12. Rock Paintings.

    ERIC Educational Resources Information Center

    Jones, Julienne Edwards

    1998-01-01

    Discusses the integration of art and academics in a fifth-grade instructional unit on Native American culture. Describes how students studied Native American pictographs, designed their own pictographs, made their own tools, and created rock paintings of their pictographs using these tools. Provides a list of references on Native American…

  13. Perspective Painting.

    ERIC Educational Resources Information Center

    Gray, Joni

    2002-01-01

    One fourth grade class studied Van Gogh by investigating his art and life on the computer, painting still lifes, then learning to draw in perspective, creating colorful images of their own bedrooms using Van Gogh's bedroom as a model. Students extended their learning by examining relevant literature and completing timelines, biographical reports,…

  14. Fatal pediatric poisoning from leaded paint--Wisconsin, 1990

    SciTech Connect

    Not Available

    1991-03-29

    Although fatal lead poisoning among children occurs rarely in the United States, it represents a medical and public health emergency. This report summarizes the investigation of a child who died from poisoning associated with ingestion of lead-based paint.

  15. Painting models

    NASA Astrophysics Data System (ADS)

    Baart, F.; Donchyts, G.; van Dam, A.; Plieger, M.

    2015-12-01

    The emergence of interactive art has blurred the line between electronic, computer graphics and art. Here we apply this art form to numerical models. Here we show how the transformation of a numerical model into an interactive painting can both provide insights and solve real world problems. The cases that are used as an example include forensic reconstructions, dredging optimization, barrier design. The system can be fed using any source of time varying vector fields, such as hydrodynamic models. The cases used here, the Indian Ocean (HYCOM), the Wadden Sea (Delft3D Curvilinear), San Francisco Bay (3Di subgrid and Delft3D Flexible Mesh), show that the method used is suitable for different time and spatial scales. High resolution numerical models become interactive paintings by exchanging their velocity fields with a high resolution (>=1M cells) image based flow visualization that runs in a html5 compatible web browser. The image based flow visualization combines three images into a new image: the current image, a drawing, and a uv + mask field. The advection scheme that computes the resultant image is executed in the graphics card using WebGL, allowing for 1M grid cells at 60Hz performance on mediocre graphic cards. The software is provided as open source software. By using different sources for a drawing one can gain insight into several aspects of the velocity fields. These aspects include not only the commonly represented magnitude and direction, but also divergence, topology and turbulence .

  16. Dissolution of lead paint in aqueous solutions

    SciTech Connect

    Barnes, G.L.; Davis, A.P.

    1996-07-01

    An analysis of the rate and extent of lead leaching from a lead-based paint was completed. At low-solution pH, dissolution was rapid and approached 80% of the total lead. Residual lead can be estimated based on the predicted solubility of lead carbonate and basic lead carbonate. Release of lead from the paint was slower than that from pure basic lead carbonate due to inhibition by the paint matrix. Although the dissolved concentration of lead in solution at neutral/high pH was low, the paint binder was apparently destroyed at these pH values, releasing colloidal lead pigment particles. The presence of ethylenediaminetetraacetic acid (EDTA) and nitrilotriacetic acid (NTA) enhanced both the rate and degree of lead dissolution, while benzoic acid had a minimal effect.

  17. 23 CFR 772.11 - Noise abatement.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... OF HIGHWAY TRAFFIC NOISE AND CONSTRUCTION NOISE § 772.11 Noise abatement. (a) In determining and abating traffic noise impacts, primary consideration is to be given to exterior areas. Abatement will usually be necessary only where frequent human use occurs and a lowered noise level would be of...

  18. 23 CFR 772.11 - Noise abatement.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... OF HIGHWAY TRAFFIC NOISE AND CONSTRUCTION NOISE § 772.11 Noise abatement. (a) In determining and abating traffic noise impacts, primary consideration is to be given to exterior areas. Abatement will usually be necessary only where frequent human use occurs and a lowered noise level would be of...

  19. Biological abatement of enzyme inhibitors

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Lignocellulose pretreatments release phenolic compounds that cause enzyme inhibition and deactivation. Bio-abatement, the biological removal of furfurals, acetic acid and phenolics, may utilize fungal fermentation to metabolize these compounds to CO2, water, cell mass, and heat. Our work with Coni...

  20. Lead Abatement Worker Skill Standards.

    ERIC Educational Resources Information Center

    Laborers-AGC Education and Training Fund, Pomfret Center, CT.

    This document identifies skill standards for lead abatement in a manner that is easy to understand, useful, and meaningful to workers, educators, trainers, labor leaders, contractors, and project owners. To meet the needs of the various users of this document who will have a different application of the standards and seek different information,…

  1. Asbestos Abatement--Practical Considerations.

    ERIC Educational Resources Information Center

    Sedrel, Roy A.

    Illinois Senate Bill 1644, the recently passed "Asbestos Abatement Act," requires all schools in the state, public and private alike, to remove friable asbestos by whichever comes first: July 1, 1989, or 3 years following the establishment of a system for state funding for corrective action. This document addresses practical considerations in…

  2. Asbestos Abatement: Start to Finish.

    ERIC Educational Resources Information Center

    Makruski, Edward D.

    1984-01-01

    An EPA survey of the largest school districts in the nation revealed that over 50 percent have not inspected for asbestos and two-thirds have failed to notify parents adequately. Seven steps are therefore provided for successful asbestos abatement, in anticipation of tougher regulations now under consideration. (TE)

  3. An evaluation of the effectiveness of lead paint hazard reduction when conducted by homeowners and landlords

    SciTech Connect

    Etre, L.A.; Reynolds, S.J.; Burmeister, L.F.; Whitten, P.S.; Gergely, R.

    1999-08-01

    This research project was conducted in collaboration with the Iowa Department of Public Health to evaluate whether property owners who follow recommended procedures for lead-based paint removal/repair can do the work safely and effectively. This study included 29 homes where a lead-based paint hazard had been identified and lead-based paint was removed or repaired (hazard reduction). Exposure evaluation included pre-project surface dust wipe sampling, air monitoring during lead-based paint removal, post-project surface dust wipe sampling, and pre- and post-project blood samples from adult study participants. The comparison of surface dust wipe samples taken before and after lead paint hazard reduction was used to evaluate the effectiveness of lead paint hazard reduction. The lead loadings on window sill surfaces in the work area were significantly lower after completion of the project, and the lead-based paint removal did not contaminate the adjoining living area. The proportion of homes with surface dust lead loading exceeding Department of Housing and Urban Development (HUD) clearance standard was 73% pre-project and 38% post-project. Personal airborne exposures during lead removal activities reinforce the need to respiratory protection and good hygiene. There was no difference in adult pre-/post-blood levels, indicating that participants die remove lead in a safe manner with respect to their own exposures. The results indicate that hazard reduction can be done effectively when recommended procedures for the removal of lead-based paint are followed.

  4. 76 FR 56136 - Lead-Based Paint Renovation, Repair and Painting, and Pre-Renovation Education Activities in...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-12

    ... listings at http://www.gpoaccess.gov/fr/ . 2. In person: you may read this document, and certain other... teach renovation classes, that individuals performing renovation activities are properly trained and...) regulations governing renovation activities. See 73 FR 21692. These regulations require that in order to...

  5. 76 FR 12106 - Lead-Based Paint Renovation, Repair and Painting Activities in Target Housing and Child Occupied...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-04

    ... enforcement. The 402(c)(3) program ensures that training providers are accredited to teach renovation classes..., that firms are certified as renovation firms, and that specific work practices are followed during.... In the Federal Register dated April 22, 2008 (73 FR 21692), EPA promulgated final TSCA section...

  6. 75 FR 39524 - Lead-Based Paint Renovation, Repair and Painting, and Pre-Renovation Education Activities in...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-09

    ... Target Housing and Child Occupied Facilities; State of Oregon. Notice of Self-Certification Program... means EPA will not know your identity or contact information unless you provide it in the body of your...) of TSCA, and submitted a self-certification that these programs are at least as protective as...

  7. 75 FR 51808 - Lead-Based Paint Renovation, Repair and Painting Activities in Target Housing and Child Occupied...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-23

    ... Facilities; State of Rhode Island and State of Massachusetts. Notice of Self-Certification Program... Control Act (TSCA), 15 U.S.C. 2684(a), and 40 CFR 745.324(d)(2), to administer and enforce requirements..., identified by docket control number, EPA-R01-OPPT- 2010-0470 must be received on or before October 7,...

  8. 75 FR 13127 - Lead-Based Paint Renovation, Repair and Painting Activities in Target Housing and Child Occupied...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-18

    ... Facilities; State of Iowa. Notice of Self-Certification Program Authorization, Request for Public Comment... Control Act (TSCA), 15 U.S.C. 2684(a), and 40 CFR 745.324(d)(2), to administer and enforce requirements... control number EPA-R07-OPPT-2010- 0155, must be received on or before May 3, 2010. In addition, a...

  9. 75 FR 6383 - Lead-Based Paint Renovation, Repair and Painting, and Pre-Renovation Education Activities in...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-09

    ... hazard investigator or by a certified renovator using a Wisconsin-recognized test kit. The work is minor... Exposure Reduction. In the Federal Register dated April 22, 2008, (73 FR 21692), EPA promulgated final TSCA... dust sampling technicians. In the Federal Register of June 1, 1998, (63 FR 29908), EPA...

  10. 76 FR 27044 - Lead-Based Paint Renovation, Repair and Painting, and Pre-Renovation Education Activities in...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-10

    ... certified lead inspector, risk assessor or by a certified renovator using an EPA-recognized test kit. The... Reduction. In the Federal Register dated April 22, 2008, (73 FR 21692), EPA promulgated final TSCA section... dust sampling technicians. In the Federal Register of June 1, 1998, (63 FR 29908), EPA...

  11. 24 CFR 35.1320 - Lead-based paint inspections, paint testing, risk assessments, lead-hazard screens, and...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... by a State or Tribal program authorized by the EPA under 40 CFR 745.324, or by the EPA at 40 CFR 745... either by a state or tribal program authorized by the EPA, or by the EPA at 40 CFR 745.227(c), (d), and... promulgated by the EPA at 40 CFR 745.227(h) or, if such standards are not in effect, the following levels...

  12. 24 CFR 35.1320 - Lead-based paint inspections, paint testing, risk assessments, lead-hazard screens, and...

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... by a State or Tribal program authorized by the EPA under 40 CFR 745.324, or by the EPA at 40 CFR 745... either by a state or tribal program authorized by the EPA, or by the EPA at 40 CFR 745.227(c), (d), and... promulgated by the EPA at 40 CFR 745.227(h) or, if such standards are not in effect, the following levels...

  13. 24 CFR 35.1320 - Lead-based paint inspections, paint testing, risk assessments, lead-hazard screens, and...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... by a State or Tribal program authorized by the EPA under 40 CFR 745.324, or by the EPA at 40 CFR 745... either by a state or tribal program authorized by the EPA, or by the EPA at 40 CFR 745.227(c), (d), and... promulgated by the EPA at 40 CFR 745.227(h) or, if such standards are not in effect, the following levels...

  14. 24 CFR 35.1320 - Lead-based paint inspections, paint testing, risk assessments, lead-hazard screens, and...

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... by a State or Tribal program authorized by the EPA under 40 CFR 745.324, or by the EPA at 40 CFR 745... either by a state or tribal program authorized by the EPA, or by the EPA at 40 CFR 745.227(c), (d), and... promulgated by the EPA at 40 CFR 745.227(h) or, if such standards are not in effect, the following levels...

  15. 24 CFR 35.1320 - Lead-based paint inspections, paint testing, risk assessments, lead-hazard screens, and...

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... by a State or Tribal program authorized by the EPA under 40 CFR 745.324, or by the EPA at 40 CFR 745... either by a state or tribal program authorized by the EPA, or by the EPA at 40 CFR 745.227(c), (d), and... promulgated by the EPA at 40 CFR 745.227(h) or, if such standards are not in effect, the following levels...

  16. Pressure Sensitive Paints

    NASA Technical Reports Server (NTRS)

    Liu, Tianshu; Bencic, T.; Sullivan, J. P.

    1999-01-01

    This article reviews new advances and applications of pressure sensitive paints in aerodynamic testing. Emphasis is placed on important technical aspects of pressure sensitive paint including instrumentation, data processing, and uncertainty analysis.

  17. 40 CFR 745.238 - Fees for accreditation and certification of lead-based paint activities.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...-certification (every 3 years, see 40 CFR 745.226(f)(7) for details) Firm $550 $550 Combined Renovation and Lead..., see 40 CFR 745.225(f)(1) for details) Initial CourseInspector Risk assessor Supervisor Worker Project... Activities—Individual Certification Re-certification (every 3 years, see 40 CFR 745.226(e)(1) for...

  18. 24 CFR 35.1355 - Ongoing lead-based paint maintenance and reevaluation activities.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... assessment and have the samples analyzed, in accordance with 40 CFR 745.227(b)(3)(4), but only if reliable... CFR 745.227(d)(8)-(11), but only if the soil lead levels have not been previously measured. (C) The... reduction activities. The report shall include the information in 40 CFR 745.227(d)(11), and shall:...

  19. I Can Paint!

    ERIC Educational Resources Information Center

    Hart, Kate; Bower, Robin, Ed.

    This book gives detailed information concerning the use of tools and media of paint. It aims at developing skills and knowledge that will allow young students to express themselves by painting. The book is organized into five sections with subheadings, including: (1) "Introduction"; (2) "Exploring Paint As We Use..." with subheadings: "Hands";…

  20. Paints and Preservatives.

    ERIC Educational Resources Information Center

    Powell, Larry E.; Miller, Larry E.

    The publication contains an outline for use by agriculture teachers in developing a teaching plan for a unit on paints and preservatives. The topics included are (1) recognizing, solving, and preventing paint problems and (2) operating and using power spray painting equipment. Items presented for each topic are: the situation, (intended to inform…

  1. Egyptian Tomb Painting.

    ERIC Educational Resources Information Center

    Schroeder, Liesa

    1999-01-01

    Provides an activity where sixth-grade students replicated the Egyptian art form of tomb painting. Explains that the students researched information about Egyptian culture and history in order to familiarize themselves with Egyptian wall-painting style. Discusses the process of creating tomb paintings in detail. (CMK)

  2. 29 CFR 1903.19 - Abatement verification.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 29 Labor 5 2014-07-01 2014-07-01 false Abatement verification. 1903.19 Section 1903.19 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR INSPECTIONS, CITATIONS AND PROPOSED PENALTIES § 1903.19 Abatement verification. Purpose. OSHA's inspections are intended to result in...

  3. AHERA CLEARANCE AT TWENTY ABATEMENT SITES

    EPA Science Inventory

    A study was conducted during the summer of 1988 to document Asbestos Hazard Emergency Response Act (AHERA) clearance air-sampling practices and clearance concentrations of airborne asbestos at 20 asbestos-abatement sites in New Jersey. Each abatement took place in a school buildi...

  4. Rapid new methods for paint collection and lead extraction.

    PubMed

    Gutknecht, William F; Harper, Sharon L; Winstead, Wayne; Sorrell, Kristen; Binstock, David A; Salmons, Cynthia A; Haas, Curtis; McCombs, Michelle; Studabaker, William; Wall, Constance V; Moore, Curtis

    2009-01-01

    Chronic exposure of children to lead can result in permanent physiological impairment. In adults, it can cause irritability, poor muscle coordination, and nerve damage to the sense organs and nerves controlling the body. Surfaces coated with lead-containing paints are potential sources of exposure to lead. In April 2008, the U.S. Environmental Protection Agency (EPA) finalized new requirements that would reduce exposure to lead hazards created by renovation, repair, and painting activities, which disturb lead-based paint. On-site, inexpensive identification of lead-based paint is required. Two steps have been taken to meet this challenge. First, this paper presents a new, highly efficient method for paint collection that is based on the use of a modified wood drill bit. Second, this paper presents a novel, one-step approach for quantitatively grinding and extracting lead from paint samples for subsequent lead determination. This latter method is based on the use of a high-revolutions per minute rotor with stator to break up the paint into approximately 50 micron-size particles. Nitric acid (25%, v/v) is used to extract the lead in <3 minutes. Recoveries are consistently >95% for real-world paints, National Institute of Standards and Technology's standard reference materials, and audit samples from the American Industrial Hygiene Association's Environmental Lead Proficiency Analytical Testing Program. This quantitative extraction procedure, when paired with quantitative paint sample collection and lead determination, may enable the development of a lead paint test kit that will meet the specifications of the final EPA rule.

  5. 24 CFR 35.1015 - Visual assessment, paint stabilization, and maintenance.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 24 Housing and Urban Development 1 2012-04-01 2012-04-01 false Visual assessment, paint..., Department of Housing and Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Acquisition, Leasing, Support Services, or Operation § 35.1015 Visual assessment,...

  6. 24 CFR 35.1015 - Visual assessment, paint stabilization, and maintenance.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 1 2010-04-01 2010-04-01 false Visual assessment, paint..., Department of Housing and Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Acquisition, Leasing, Support Services, or Operation § 35.1015 Visual assessment,...

  7. 24 CFR 35.1015 - Visual assessment, paint stabilization, and maintenance.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 24 Housing and Urban Development 1 2014-04-01 2014-04-01 false Visual assessment, paint..., Department of Housing and Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Acquisition, Leasing, Support Services, or Operation § 35.1015 Visual assessment,...

  8. 24 CFR 35.1015 - Visual assessment, paint stabilization, and maintenance.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 24 Housing and Urban Development 1 2011-04-01 2011-04-01 false Visual assessment, paint..., Department of Housing and Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Acquisition, Leasing, Support Services, or Operation § 35.1015 Visual assessment,...

  9. 24 CFR 35.1015 - Visual assessment, paint stabilization, and maintenance.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 24 Housing and Urban Development 1 2013-04-01 2013-04-01 false Visual assessment, paint..., Department of Housing and Urban Development LEAD-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Acquisition, Leasing, Support Services, or Operation § 35.1015 Visual assessment,...

  10. Lead Paint Poisonings: How Can Innovative Technology Make a Difference?

    EPA Science Inventory

    Lead is a toxic metal that may cause a range of health effects, from behavioral problems and learning disabilities, to seizures and death. Children six years old and under are most at risk. Exposure to lead usually occurs due to the presence of deteriorating lead-based paint (LBP...

  11. Interaction of pollution abatement with world dynamics

    NASA Technical Reports Server (NTRS)

    Smith, G. L.

    1973-01-01

    The world dynamics model of Jay W. Forrester was modified to account for pollution abatement. In the modified model, it is assumed that as pollution increases, efforts are made to control pollution. There is a competition between food supply, material standard of living, and pollution abatement for capital, and time is required for diversion of capital toward pollution abatement. Inclusion of pollution abatement in the model drastically alters the response of the world system for the case in which depletion of natural resources is not considered. Instead of undergoing a pollution catastrophe, all system levels move more or less smoothly toward an equilibrium. A FORTRAN program listing of the modified world dynamics model is included.

  12. Pollock without Paint?

    ERIC Educational Resources Information Center

    Sutley, Jane

    2011-01-01

    This article describes how the author exposes her students to the world of Jackson Pollock, the artist who brings to mind dripping, meandering, splashing puddles of paint. Pollock's action paintings of the late 1940s-'50s call out for unfettered movement, fluidity, and freedom of application. Is it even possible to capture the action, rhythm and…

  13. Paint-Stirrer Submarine

    ERIC Educational Resources Information Center

    Young, Jocelyn; Hardy, Kevin

    2007-01-01

    In this article, the authors discuss a unique and challenging laboratory exercise called, the paint-stir-stick submarine, that keeps the students enthralled. The paint-stir-stick submarine fits beautifully with the National Science Education Standards Physical Science Content Standard B, and with the California state science standards for physical…

  14. Jasper Johns' Painted Words.

    ERIC Educational Resources Information Center

    Levinger, Esther

    1989-01-01

    States that the painted words in Jasper Johns' art act in two different capacities: concealed words partake in the artist's interrogation of visual perception; and visible painted words question classical representation. Argues that words are Johns' means of critiquing modernism. (RS)

  15. Magnetic memory of oil paintings

    NASA Astrophysics Data System (ADS)

    Costa Ribeiro, P.; Bruno, A. C.; Carvalho, H. R.; Kafensztok, S. M.; Almeida, P. O.; Wolff, C. S.; Lins de Barros, H.; Acosta-Avalos, D.; Symko, O. G.

    2007-10-01

    The color in oil paints is obtained sometimes from magnetic minerals. This fact implies that oil paintings could present an intrinsic magnetization. Magnetic imaging of an oil painting consists in the measurement of magnetic flux related to the magnetization of the painting. In this report results of magnetic measurements show that oil paints from different manufacturers (Maimeri, Pebeo, and Grumbacher) are magnetic. The magnetic imagings of four similar oil paintings done with the same visual color, obtained using different mixtures of oil paints for each painting, were different. This shows that the magnetic imaging can be used as a fingerprint for the oil paintings. Magnetic imaging was obtained for oil paintings done by Oswald, Bianco, and Timoteo, all of them are Brazilian painters. The imaging obtained in measurements at different times was always the same, showing that the magnetic images are stable. This leads to the conclusion that magnetic imaging would be a common authentication technique of paintings.

  16. 24 CFR 35.1340 - Clearance.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Methods and Standards for Lead-Paint... abatement of lead-based paint or lead-based paint hazards shall be performed in accordance with 40 CFR 745... the steps set forth at 40 CFR 745.227(e)(8). If clearance is being performed after lead-based...

  17. 24 CFR 35.1340 - Clearance.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Methods and Standards for Lead-Paint... abatement of lead-based paint or lead-based paint hazards shall be performed in accordance with 40 CFR 745... the steps set forth at 40 CFR 745.227(e)(8). If clearance is being performed after lead-based...

  18. 24 CFR 35.1340 - Clearance.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ...-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Methods and Standards for Lead-Paint... abatement of lead-based paint or lead-based paint hazards shall be performed in accordance with 40 CFR 745... the steps set forth at 40 CFR 745.227(e)(8). If clearance is being performed after lead-based...

  19. 24 CFR 35.1340 - Clearance.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Methods and Standards for Lead-Paint... abatement of lead-based paint or lead-based paint hazards shall be performed in accordance with 40 CFR 745... the steps set forth at 40 CFR 745.227(e)(8). If clearance is being performed after lead-based...

  20. Paint-Overspray Catcher

    NASA Technical Reports Server (NTRS)

    Weinstein, Leonard M.

    2003-01-01

    An apparatus to catch paint overspray has been proposed. Overspray is an unavoidable parasitic component of spray that occurs because the flow of air or other gas in the spray must turn at the sprayed surface. Very small droplets are carried away in this turning flow, and some land on adjacent surfaces not meant to be painted. The basic principle of the paint-spray catcher is to divert the overspray into a suction system at the boundary of the area to be painted. The paint-spray catcher (see figure) would include a toroidal plenum connected through narrow throat to a nozzle that would face toward the center of the torus, which would be positioned over the center of the area to be spray-painted. The plenum would be supported by four tubes that would also serve as suction exhaust ducts. The downstream ends of the tubes (not shown in the figure) would be connected to a filter on a suction pump. The pump would be rated to provide a suction mass flow somewhat greater than that of the directed spray gas stream, so that the nozzle would take in a small excess of surrounding gas and catch nearly all of the overspray. A small raised lip at the bottom edge of the nozzle would catch paint that landed inside the nozzle. Even if the paint is directly piston pumped, the droplets entrain an air flow by time they approach the wall, so there is always a gas stream to carry the excess droplets to the side. For long-duration spraying operations, it could be desirable to include a suction-drain apparatus to prevent overflowing and dripping of paint from inside the lip. A version without an external contraction and with the throat angled downward would be a more compact version of catcher, although it might be slightly less efficient.

  1. Heat Resistant Paint

    NASA Technical Reports Server (NTRS)

    1978-01-01

    The racing car shown is one of many coated with an inorganic paint that protects "hot parts" of automotive vehicles. Developed and manufactured by Sperex Corporation, Gardena, California, the durable, heat-resistant paint is used on car and truck exhaust systems, firewalls, brake drums and engine manifolds. NASA technology contributed to development of the paint. Sperex was provided a technical support packa'ge detailing the research of Goddard Space Flight Center on long-life inorganic coatings. The information helped Sperex perfect its own formulations.

  2. Comets in Bushman Paintings

    NASA Astrophysics Data System (ADS)

    Fraser, B.

    2007-07-01

    About ten years ago I was asked to give a talk on African astronomical folklore and spent many hours reading up on the subject. My queries eventually led me to Bert Woodhouse, a member of the archaeological society and well-known recorder of Bushman paintings. He has published seven books on Bushman paintings and has a collection of over 30 000 slides covering all aspects of the subject. One section of his collection is labeled "comets" and he kindly made copies of these slides for me to use in that talk. This paper highlights those slides and discusses the objects depicted in the paintings.

  3. Artists Paint ... Landscapes

    ERIC Educational Resources Information Center

    Herberholz, Barbara

    2012-01-01

    This article features the painting "View of Toledo," based on Toledo, a very old city located on a high plateau in Spain. By the time the artist El Greco painted the picture, he had lived there for 31 years. When one looks at the picture, one will see a storm approaching and will see the city as if it were lit by a flash of lightning. What main…

  4. 10 CFR 851.22 - Hazard prevention and abatement.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... abatement process to ensure that all identified and potential hazards are prevented or abated in a timely... appropriate; (2) Engineering controls where feasible and appropriate; (3) Work practices and...

  5. OPTIONS FOR ABATING GREENHOUSE GASES FROM EXHAUST STREAMS.

    SciTech Connect

    FTHENAKIS,V.

    2001-12-01

    This report examines different alternatives for replacing, treating, and recycling greenhouse gases. It is concluded that treatment (abatement) is the only viable short-term option. Three options for abatement that were tested for use in semiconductor facilities are reviewed, and their performance and costs compared. This study shows that effective abatement options are available to the photovoltaic (PV) industry, at reasonable cost.

  6. Hanford Site Asbestos Abatement Plan. Revision 1

    SciTech Connect

    Mewes, B.S.

    1993-09-01

    The Hanford Site Asbestos Abatement Plan (Plan) lists priorities for asbestos abatement activities to be conducted in Hanford Site facilities. The Plan is based on asbestos assessment information gathered in fiscal year 1989 that evaluated all Hanford Site facilities for the presence and condition of asbestos. Of those facilities evaluated, 414 contain asbestos-containing materials and are classified according to the potential risk of asbestos exposure to building personnel. The Plan requires that asbestos condition update reports be prepared for all affected facilities. The reporting is completed by the asbestos coordinator for each of the 414 affected facilities and transmitted to the Plan manager annually. The Plan manager uses this information to reprioritize future project lists. Currently, five facilities are determined to be Class Al, indicating a high potential for asbestos exposure. Class Al and B1 facilities are the highest priority for asbestos abatement. Abatement of the Class A1 and Bl facilities is scheduled through fiscal year 1997. Removal of asbestos in B1 facilities will reduce the risk for further Class ``A`` conditions to arise.

  7. International forensic automotive paint database

    NASA Astrophysics Data System (ADS)

    Bishea, Gregory A.; Buckle, Joe L.; Ryland, Scott G.

    1999-02-01

    The Technical Working Group for Materials Analysis (TWGMAT) is supporting an international forensic automotive paint database. The Federal Bureau of Investigation and the Royal Canadian Mounted Police (RCMP) are collaborating on this effort through TWGMAT. This paper outlines the support and further development of the RCMP's Automotive Paint Database, `Paint Data Query'. This cooperative agreement augments and supports a current, validated, searchable, automotive paint database that is used to identify make(s), model(s), and year(s) of questioned paint samples in hit-and-run fatalities and other associated investigations involving automotive paint.

  8. Lead in housing paints: an exposure source still not taken seriously for children lead poisoning in China.

    PubMed

    Lin, G Z; Peng, R F; Chen, Q; Wu, Z G; Du, L

    2009-01-01

    After prohibitions on lead gasoline additives, which have proved to be a public health accomplishment world wide, many countries focus on other exposure source of children lead poisoning. Removing lead from paints is one of the important measures. Although there have been regulatory limits on lead in paints in China, evidence reported in this article indicates that lead-based paints were very common in new paints available for housing and in existing residential paints. Twenty-nine of 58 new paint samples (50%) had lead content equal to or exceeding 600 ppm, including 14 (24%) equal to or exceeding 5000 ppm. The highest sample contained 153,000 ppm lead, about 15% of the paint weight. Thirty-two new paints (55%) contained "soluble" lead exceeding 90 ppm, the current lead limit on paints in China. Of the existing paints, 16 of 28 samples of existing paint (57%) collected from 24 kindergartens and primary schools had lead concentrations equal to or exceeding 600 ppm, including six samples (21%) equal to or exceeding 5000 ppm. The highest concentration sample contained 51,800 ppm lead, accounting for 5.2% of the paint weight. It has been shown in many areas that paint lead is a major exposure source for lead poisoning in children. This is particularly true after the phasing out of lead from gasoline. Effective limitation on lead content in new paint, and lead hazard control measures directed towards existing paint, could reduce children blood lead levels (BLLs). There has been a lead standard for paints in China since 1986 and a stricter limit was introduced in recent years. Governments should take it seriously and enforce regulations, commit a long-term challenge to eliminate paint lead as it is the threat to current and the next generation.

  9. Reading Through Paint

    NASA Technical Reports Server (NTRS)

    2004-01-01

    Two-dimensional data matrix symbols, which contain encoded letters and numbers, are permanently etched on items for identification. They can store up to 100 times more information than traditional bar codes. While the symbols provide several advantages over bar codes, once they are covered by paint they can no longer be read by optical scanners. Since most products are painted eventually, this presents a problem for industries relying on the symbols for identification and tracking. In 1987, NASA s Marshall Space Flight Center began studying direct parts marking with matrix symbols in order to track millions of Space Shuttle parts. Advances in the technology proved that by incorporating magnetic properties into the paints, inks, and pastes used to apply the matrix symbols, the codes could be read by a magnetic scanner even after being covered with paint or other coatings. NASA received a patent for such a scanner in 1998, but the system it used for development was not portable and was too costly. A prototype was needed as a lead-in to a production model. In the summer of 2000, NASA began seeking companies to build a hand-held scanner that would detect the Read Through Paint data matrix identification marks containing magnetic materials through coatings.

  10. 1. Photocopy of painting (original painting in possesion of the ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. Photocopy of painting (original painting in possesion of the family of Judge Jasper Brinton, Cairo, Egypt) Thomas Eakins, Artist 1878 SIDE AND FRONT ELEVATIONS - Brinton 1704 House, Oakland Road (Birmingham Township), Dilworthtown, Chester County, PA

  11. Monet's painting under the microscope.

    PubMed

    Dredge, Paula; Wuhrer, Richard; Phillips, Matthew R

    2003-04-01

    An oil painting by Claude Monet, Port-Goulphar, Belle-Ile 1887 (collection of the Art Gallery of New South Wales), was examined to determine both the identity of the pigments used by the artist in this painting and his technique of mixing colors and laying paint on the canvas. The extremely complex construction of the painting was revealed by optical microscopy, scanning electron microscopy (SEM), energy dispersive X-ray analysis (EDS), and X-ray mapping (XRM) analysis of cross sections of paint flakes excised from damaged regions of Port-Goulphar, Belle-Ile. Nine different pigments were found on the painting. Many of the identified colors were modern pigments that became available only late in the 19th century as a result of scientific advances in pigment chemistry. Although similar colors were available in a natural mineral form, they lacked the vivid color of their manufactured counterparts. The use of these new synthetic metallic oxide colors by Monet accounts for the brilliance of his paintings. In addition, a separation between successive paint layers was observed in some areas of paint chip cross sections, indicating that oil-based paint was applied to paint that had dried, and consequently, Port-Goulphar, Belle-Ile was painted over a long period of time. This observation is contrary to the general perception of Monet's technique of painting freely and quickly. PMID:12639239

  12. Monet's Painting under the Microscope

    NASA Astrophysics Data System (ADS)

    Dredge, Paula; Wuhrer, Richard; Phillips, Matthew R.

    2003-04-01

    An oil painting by Claude Monet, Port-Goulphar, Belle-Ile 1887 (collection of the Art Gallery of New South Wales), was examined to determine both the identity of the pigments used by the artist in this painting and his technique of mixing colors and laying paint on the canvas. The extremely complex construction of the painting was revealed by optical microscopy, scanning electron microscopy (SEM), energy dispersive X-ray analysis (EDS), and X-ray mapping (XRM) analysis of cross sections of paint flakes excised from damaged regions of Port-Goulphar, Belle-Ile. Nine different pigments were found on the painting. Many of the identified colors were modern pigments that became available only late in the 19th century as a result of scientific advances in pigment chemistry. Although similar colors were available in a natural mineral form, they lacked the vivid color of their manufactured counterparts. The use of these new synthetic metallic oxide colors by Monet accounts for the brilliance of his paintings. In addition, a separation between successive paint layers was observed in some areas of paint chip cross sections, indicating that oil-based paint was applied to paint that had dried, and consequently, Port-Goulphar, Belle-Ile was painted over a long period of time. This observation is contrary to the general perception of Monet's technique of painting freely and quickly.

  13. Paint removal using lasers

    NASA Astrophysics Data System (ADS)

    Liu, Katherine; Garmire, Elsa

    1995-07-01

    Experiments to investigate the potential for practical laser graffiti-removal systems are reported. A universal engineering curve for the time needed for removal of paint from nonconductive substrates that was valid over a range of 107 in intensity was measured with a variety of lasers. Comparable times were measured for conductive substrates, when pulses shorter than the thermal conduction times were used. Analysis suggests that Q-switched Nd:YAG lasers may be the most efficient means for removing graffiti and other unwanted paint. An 1-m2 area of paint 14 mu m thick can be removed in approximately 10 min with a 50-Hz laser system of 15-W average power.

  14. Paint removal using lasers.

    PubMed

    Liu, K; Garmire, E

    1995-07-20

    Experiments to investigate the potential for practical laser graffiti-removal systems are reported. A universal engineering curve for the time needed for removal of paint from nonconductive substrates that was valid over a range of 10(7) in intensity was measured with a variety of lasers. Comparable times were measured for conductive substrates, when pulses shorter than the thermal conduction times were used. Analysis suggests that Q-switched Nd:YAG lasers may be the most efficient means for removing graffiti and other unwanted paint. An 1-m(2) area of paint 14 µm thick can be removed in approximately 10 min with a 50-Hz laser system of 15-W average power.

  15. Vitrification of lead contained in lead based organic coatings using thermal spray technology

    SciTech Connect

    Covey, S.W.; Petreanu, J.P.; Kumar, A.

    1996-12-31

    The feasibility of in situ vitrification of lead oxide contained in red lead based organic coatings was investigated. The removal of organic lead based primers and paints has been achieved by a flame spray process that uses a glass/ceramic compound designed for high lead solubility and resistance to devitrification. The two designer glass waste forms that exhibited the best results belong to the lead borosilicate and the lead alkali silicate systems. The glass/ceramic compounds were prepared by fusing, fritting, and ball milling to produce the desired powder. The resulting powder was collected and used to flame spray previously prepared samples containing a commonly used red lead primer. Oxyacetylene flame spray technology was used to apply the glass compound to the steel substrate. The resulting glass waste was collected and analyzed for lead content using X-Ray Spectrometry (XRS) and the lead cation leachability rates using the US Environmental Agency approved Toxicity Characteristic Leaching Procedure (TCLP). Of the alkali silicate glass compositions that were tested, the least lead leached from the glass was 2 ppm of lead. The lowest leachate concentration from the borosilicate glass compositions was 12 ppm of lead.

  16. Oil-based paint poisoning

    MedlinePlus

    Hydrocarbons are the primary poisonous ingredient in oil paints. Some oil paints have heavy metals such as ... Gummin DD. Hydrocarbons. In: Nelson LS, Lewin NA, Howland MA, et al., eds. Goldfrank's Toxicologic Emergencies . 9th ed. New York, NY: ...

  17. Process Waste Assessment - Paint Shop

    SciTech Connect

    Phillips, N.M.

    1993-06-01

    This Process Waste Assessment was conducted to evaluate hazardous wastes generated in the Paint Shop, Building 913, Room 130. Special attention is given to waste streams generated by the spray painting process because it requires a number of steps for preparing, priming, and painting an object. Also, the spray paint booth covers the largest area in R-130. The largest and most costly waste stream to dispose of is {open_quote}Paint Shop waste{close_quotes} -- a combination of paint cans, rags, sticks, filters, and paper containers. These items are compacted in 55-gallon drums and disposed of as solid hazardous waste. Recommendations are made for minimizing waste in the Paint Shop. Paint Shop personnel are very aware of the need to minimize hazardous wastes and are continuously looking for opportunities to do so.

  18. Miniature spray-painting booth

    NASA Technical Reports Server (NTRS)

    Fee, K. W.

    1970-01-01

    Transparent spray booth provides method for quality painting and repair of surfaces in clean room or other specialized environments. Overspray and virtually all contaminating vapor and odor can be eliminated. Touch-up painting is achieved with spray gun.

  19. Photo-oxidation of NO using an exterior paint--screening of various commercial titania in powder pressed and paint films.

    PubMed

    Aguia, C; Angelo, J; Madeira, Luis M; Mendes, A

    2011-07-01

    The present work aims to evaluate the photocatalytic activity of photo-TiO(2) from various producers (Evonik, Kemira, Kronos, Millennium, Sachtleben and Tayca), in the form of powder pressed films and upon incorporation in a water-based paint, for outdoor NO abatement. The photocatalytic activity of the different samples was evaluated in terms of NO conversion and selectivity towards nitrite and nitrate ions following approximately the ISO 22197-1:2007(E) standard. The highest yields obtained for powder pressed films were achieved with VLP7000 (0.70), followed by VLP7101 (0.55) and UVLP7500 (0.55), all from Kronos. On the other hand, when incorporated in paint films, the highest yields were obtained with PC500 and PC105 from Millennium and UV100 from Sachtleben (ca. 0.15). The paint matrix plays an important role on the photocatalytic activity. In particular, the time for steady state is one or two orders of magnitude higher when the photocatalysts are incorporated in paint films in relation to the powder pressed films. The paint films were activated following the procedure recommended by the above-mentioned standard. However, the photocatalytic activity of films incorporating P25 (Evonik) was displayed only when higher power radiation and higher humidity conditions were used. This allowed for similar levels of photocatalytic activity as the other paint films.

  20. Tanjore: Mystical Painting of India

    ERIC Educational Resources Information Center

    Henn, Cynthia A.

    2004-01-01

    Tanjore (or Thanjavur or Thanlavoor) paintings are one of the most popular traditional art forms in Southern India. These ornate religious paintings involve Hindu mythology. The paintings are noted for their adornment of gold and semiprecious stones such as rubies, emeralds, and pearls. Currently, the semiprecious stones are often substituted…

  1. Static-Suppressing Optical Paint

    NASA Technical Reports Server (NTRS)

    Birnbaum, M. M.; Metzler, E. C.; Cleland, E. L.

    1985-01-01

    Electrically conductive flat black paint adheres well to magnesium, aluminum, fiberglass, and other materials. Paint absorbs stray light in optical instruments while preventing buildup of electrostatic fields and arcing. Paint consists of primer and topcoat, both containing electricallyconductive carbon-black powder. Primer two-part epoxy base, and topcoat polyurethane base.

  2. Paint by Numbers Revived!

    ERIC Educational Resources Information Center

    Hahn, Nic

    2012-01-01

    Remember paint by numbers? This revived trend was a perfect solution to teaching geometric shapes to the author's first-grade students. Geometric shapes are identified and used in early elementary art classrooms, but this lesson gives students a deeper understanding of shape, encourages problem-solving, and makes a strong correlation between math…

  3. Paint it nanoblack

    NASA Astrophysics Data System (ADS)

    Perkowitz, Sidney

    2016-08-01

    Ever since our ancestors painted images on the walls of caves, artists have sought pigments to represent the 10 million tints that humans can differentiate. Now they have a new ally: researchers who are using optical design principles, nanotechnology and inspiration from nature to create deeper blacks and purer whites.

  4. Painting Cloth with Crayons.

    ERIC Educational Resources Information Center

    Asch, Rosalie L.

    1979-01-01

    Painting cloth with crayons is suggested as a challenging art project, especially for students who have difficulty with the complex tools and processes typical of more advanced textile work. Instructions are given for creating decorative banners with this technique. One of seven articles in this issue on fiber arts. (Author/SJL)

  5. Cultural Collage Paintings

    ERIC Educational Resources Information Center

    Coy, Mary

    2011-01-01

    In this article, the author describes a cultural collage painting project. Three things served as the impetus for this project: (1) a desire for students to explore the theme of "culture"; (2) an appreciation for the photo-montaged, layered images one sees in print media; and (3) noticing that projects from core subject areas hanging on the walls…

  6. Artists Paint ... Fantasy

    ERIC Educational Resources Information Center

    Herberholz, Barbara

    2012-01-01

    When he painted a portrait of Holy Roman Emperor Rudolph II (1552-1612), Giuseppe Arcimboldo used his imagination, and portrayed him as "Vertumnus," the Roman god of vegetation and the seasons. It's fun to find the different fruits, vegetables and flowers he used: pea-pod eyelids, a gourd for the forehead. Court painters of the time usually…

  7. Abating exhaust noises in jet engines

    NASA Technical Reports Server (NTRS)

    Schwartz, I. R. (Inventor)

    1974-01-01

    A noise abating improvement for jet engines including turbojets, turbofans, turboprops, ramjets, scramjets, and hybrid jets is introduced. A provision is made for an apparatus in the primary and/or secondary flow streams of the engines; the apparatus imparts to the exhaust gases a component rotation or swirl about the engine's longitudinal axis. The rotary component in the exhaust gases causes a substantial suppression of sound energy build up normally produced by an axial flow exhaust system.

  8. 29 CFR 1903.19 - Abatement verification.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) of this section as well as the posting requirement of 29 CFR 1903.16. (2) The employer must use a... designed and used in accordance with 29 CFR 1926.20(b)(3) and 29 CFR 1926.200(h) is deemed by OSHA to meet.... Appendix A to Section 1903.19—Sample Abatement-Certification Letter (Nonmandatory) (Name), Area Director...

  9. 29 CFR 1903.19 - Abatement verification.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) of this section as well as the posting requirement of 29 CFR 1903.16. (2) The employer must use a... designed and used in accordance with 29 CFR 1926.20(b)(3) and 29 CFR 1926.200(h) is deemed by OSHA to meet.... Appendix A to Section 1903.19—Sample Abatement-Certification Letter (Nonmandatory) (Name), Area Director...

  10. 29 CFR 1903.19 - Abatement verification.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) of this section as well as the posting requirement of 29 CFR 1903.16. (2) The employer must use a... designed and used in accordance with 29 CFR 1926.20(b)(3) and 29 CFR 1926.200(h) is deemed by OSHA to meet.... Appendix A to Section 1903.19—Sample Abatement-Certification Letter (Nonmandatory) (Name), Area Director...

  11. Toxicity of Abate? to green frog tadpoles

    USGS Publications Warehouse

    Sparling, D.W.; Lowe, T.P.; Pinkney, A.E.

    1997-01-01

    Green frog tadpoles were exposed to a 96hr toxicity test using Abate4E, the formulation for temephos used in mosquito control. Concentrations ranged from 0 (control) to 10 uL/L. Concentrations as low as 2.60 uL/L reduced activity for several hours after exposure but had negligible effects after 24 hr, presumably because the temephos had degraded during that time. The LC50 for Abate was 4.24 uL/L. Butyrlcholinesterase activity, which is known to be more sensitive than acetylcholinesterase (AChE), declined with concentration of Abate with a significant depression bserved between controls and the lowest concentration used of 1.86 uL/L. However, AChE activity increased with concentration of temephos. Temephos must be converted to its sulfone form to reach maximum toxicity and tadpoles may be inefficient in metabolizing the parent compound. Hence, temephos may have stressed the tadpoles, causing them to release more acetylcholine and AChE. Toxic levels were above expected ambient concentrations found during mosquito control operations.

  12. 24 CFR 203.673 - Habitability.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... market value of the property. The cost of hazard reduction or abatement of lead-based paint hazards in the property, as required by the Lead-Based Paint Poisoning Prevention Act (42 U.S.C. 4821-4846), and the Residential Lead-Based Paint Hazard Reduction Act of 1992 (42 U.S.C. 4851-4856), and...

  13. Reducer Selection When Doing Overall Paint Jobs Using Enamel Paints. Lesson Plan No. 1 of Auto Repair and Painting.

    ERIC Educational Resources Information Center

    Tyau, Layton M.

    This lesson, which is part of a high school course in auto body repair and painting, deals with selecting a reducer when doing overall paint jobs using enamel paints. Students are taught the general properties of different types of enamel paints and selection of the proper reducer for each type of paint, depending on the weather and the specific…

  14. 40 CFR 745.226 - Certification of individuals and firms engaged in lead-based paint activities: target housing and...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... work, or construction); or (3) Certification as an industrial hygienist, professional engineer, registered architect and/or certification in a related engineering/health/environmental field (e.g., safety...) Bachelor's degree in engineering, architecture, or a related profession, and 1 year of experience...

  15. 77 FR 16796 - Lead Requirements for Lead-Based Paint Activities in Target Housing and Child-Occupied Facilities...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-22

    ... listings at http://www.gpoaccess.gov/fr/ . 2. In person: The State submittal is also available for public... of submission, which was March 29, 1999. (See, 64 FR 27266, May 19, 1999). In 2011, the Arkansas... activities program. On August 29, 1996 (61 FR 45777) (FRL-5389-9), EPA promulgated final TSCA section...

  16. 40 CFR 745.226 - Certification of individuals and firms engaged in lead-based paint activities: target housing and...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... professional, environmental scientist); or (4) A high school diploma (or equivalent), and at least 3 years of... receive certification in the future. (iv) The opportunity and method for requesting a hearing prior...

  17. Sampling the Soils around a Residence Containing Lead-Based Paints: An X-Ray Fluorescence Experiment

    ERIC Educational Resources Information Center

    Bachofer, Steven J.

    2008-01-01

    Sampling experiments utilizing field portable instruments are instructional since students collect data following regulatory protocols, evaluate it, and begin to recognize their civic responsibilities upon collecting useful data. A lead-in-soil experiment educated students on a prevalent exposure pathway. The experimental site was a pre-1950…

  18. Nutrient abatement potential and abatement costs of waste water treatment plants in the Baltic Sea region.

    PubMed

    Hautakangas, Sami; Ollikainen, Markku; Aarnos, Kari; Rantanen, Pirjo

    2014-04-01

    We assess the physical potential to reduce nutrient loads from waste water treatment plants in the Baltic Sea region and determine the costs of abating nutrients based on the estimated potential. We take a sample of waste water treatment plants of different size classes and generalize its properties to the whole population of waste water treatment plants. Based on a detailed investment and operational cost data on actual plants, we develop the total and marginal abatement cost functions for both nutrients. To our knowledge, our study is the first of its kind; there is no other study on this issue which would take advantage of detailed data on waste water treatment plants at this extent. We demonstrate that the reduction potential of nutrients is huge in waste water treatment plants. Increasing the abatement in waste water treatment plants can result in 70 % of the Baltic Sea Action Plan nitrogen reduction target and 80 % of the Baltic Sea Action Plan phosphorus reduction target. Another good finding is that the costs of reducing both nutrients are much lower than previously thought. The large reduction of nitrogen would cost 670 million euros and of phosphorus 150 million euros. We show that especially for phosphorus the abatement costs in agriculture would be much higher than in waste water treatment plants.

  19. Emission abatement system utilizing particulate traps

    DOEpatents

    Bromberg, Leslie; Cohn, Daniel R.; Rabinovich, Alexander

    2004-04-13

    Emission abatement system. The system includes a source of emissions and a catalyst for receiving the emissions. Suitable catalysts are absorber catalysts and selective catalytic reduction catalysts. A plasma fuel converter generates a reducing gas from a fuel source and is connected to deliver the reducing gas into contact with the absorber catalyst for regenerating the catalyst. A preferred reducing gas is a hydrogen rich gas and a preferred plasma fuel converter is a plasmatron. It is also preferred that the absorber catalyst be adapted for absorbing NO.sub.x.

  20. 46 CFR 72.05-45 - Paint.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 3 2012-10-01 2012-10-01 false Paint. 72.05-45 Section 72.05-45 Shipping COAST GUARD... Protection § 72.05-45 Paint. (a) An excessive number of coats of paint will be discouraged unless noncombustible paint is used. (b) Nitrocellulose or other highly flammable or noxious fume-producing paints...

  1. 46 CFR 72.05-45 - Paint.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 3 2014-10-01 2014-10-01 false Paint. 72.05-45 Section 72.05-45 Shipping COAST GUARD... Protection § 72.05-45 Paint. (a) An excessive number of coats of paint will be discouraged unless noncombustible paint is used. (b) Nitrocellulose or other highly flammable or noxious fume-producing paints...

  2. 29 CFR 1915.35 - Painting.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 29 Labor 7 2014-07-01 2014-07-01 false Painting. 1915.35 Section 1915.35 Labor Regulations... Painting. (a) Paints mixed with toxic vehicles or solvents. (1) When paints mixed with toxic vehicles or.... (2) Where brush application of paints with toxic solvents is done in confined spaces or in...

  3. 46 CFR 72.05-45 - Paint.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 3 2013-10-01 2013-10-01 false Paint. 72.05-45 Section 72.05-45 Shipping COAST GUARD... Protection § 72.05-45 Paint. (a) An excessive number of coats of paint will be discouraged unless noncombustible paint is used. (b) Nitrocellulose or other highly flammable or noxious fume-producing paints...

  4. 46 CFR 72.05-45 - Paint.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Paint. 72.05-45 Section 72.05-45 Shipping COAST GUARD... Protection § 72.05-45 Paint. (a) An excessive number of coats of paint will be discouraged unless noncombustible paint is used. (b) Nitrocellulose or other highly flammable or noxious fume-producing paints...

  5. 46 CFR 72.05-45 - Paint.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 3 2011-10-01 2011-10-01 false Paint. 72.05-45 Section 72.05-45 Shipping COAST GUARD... Protection § 72.05-45 Paint. (a) An excessive number of coats of paint will be discouraged unless noncombustible paint is used. (b) Nitrocellulose or other highly flammable or noxious fume-producing paints...

  6. Metal concentrations and distribution in paint waste generated during bridge rehabilitation in New York State.

    PubMed

    Shu, Zhan; Axe, Lisa; Jahan, Kauser; Ramanujachary, Kandalam V; Kochersberger, Carl

    2015-09-01

    Between 1950 and 1980, lead and chromium along with other metals have been used in paint coatings to protect bridges from corrosion. In New York State with 4500 bridges in 11 Regions 2385 of the bridges have been rehabilitated and subsequently repainted after 1989 when commercial use of lead based paint was prohibited. The purpose of this research was to address the concentration and distribution of trace metals in the paint waste generated during bridge rehabilitation. Using hypothesis testing and stratified sampling theory, a representative sample size of 24 bridges from across the state was selected that resulted in 117 paint waste samples. Field portable X-ray fluorescence (FP-XRF) analysis revealed metal concentrations ranged from 5 to 168,090 mg kg(-1) for Pb, 49,367 to 799,210 mg kg(-1) for Fe, and 27 to 425,510 mg kg(-1) for Zn. Eighty percent of the samples exhibited lead concentrations greater than 5000 mg kg(-1). The elevated iron concentrations may be attributed to the application of steel grit as an abrasive blasting material routinely used by state Departments of Transportation in the paint removal process. Other metals including Ba and Cr were observed in the paint waste as well. As a result of the paint formulation, metals were found to be associated in the paint waste (Pb correlated with Cr (r=0.85)). The elevated metal concentrations observed raises concern over the potential impact of leaching from this waste stream.

  7. Nitrogen oxide abatement by distributed fuel addition

    SciTech Connect

    Wendt, J.O.L.; Meraab, J.

    1988-03-25

    The purpose of this project is to develop techniques for nitrogen oxides abatement by distributed fuel addition. The major nitrogen oxide of interest is Nitric Oxide (NO), a precursor to premature forest damage and to acid rain. Recently interest has also been evoked with respect to an additional oxide of nitrogen, namely Nitrous Oxide (N{sub 2}O). Therefore, abatement measures for NO{sub x} are being investigated to determine their influence on N{sub 2}O as well. This report briefly describes the significance of N{sub 2}O emissions to the environment and the urgent need to develop techniques that can reduce emissions of both NO and N{sub 2}O. Reburning through distributed fuel addition may be an effective technique for NO{sub x} (mainly NO) emission control as described in the previous quarterly report. Reburning may also be effective in reducing N{sub 2}O levels. A technique for N{sub 2}O measurement by gas chromatography/electron capture detection was developed during this quarter, and is described in this report. This analysis technique will be used in the proposed experimental study to investigate the effectiveness of reburning on N{sub 2}O control.

  8. Lead abatement system cuts corners, costs for utility company

    SciTech Connect

    Fuller, B.

    1996-11-01

    When Consolidated Edison Co. (New York) called for bids to remove lead from the 125-foot-tall steam-dispersion stacks at its Astoria Power Generating Station, the company specified that no lead could be released into the environment during the project. Another restriction was that any abrasive blasting for surface preparation would have to be accompanied by full-scale containment--including use of airtight seals, ventilation systems, entrance and exit air locks, and impermeable containment material--to ensure minimal discharge to the generating plant below the stack. Prospective contractors also would be required to meet Occupational Safety and Health Administration standards for medical surveillance, hygiene facilities, eating areas and personal protective equipment if lead levels exceeded 30 micrograms per cubic meter. To reduce the cost of erecting and maintaining full containment without jeopardizing health and safety criteria, Con Ed incorporated a practical solution to remove its aging, lead-based paint. The technology, comprised of a Vac-Pac{reg_sign} self-drumming HEPA filtration system, supports up to 10 operators using proprietary scalers and needleguns. The scalers are effective for flat areas, removing coatings at 45 square feet per hour, while the needleguns are designed for use on corners, edges, rivets and bolts.

  9. 76 FR 39368 - Migratory Bird Permits; Abatement Regulations

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-06

    ... bald eagles. There is currently no limit to the number of raptors an abatement permit holder may hold... depredation order or depredation permit. Any harassment, disturbance, or take of bald eagles, golden eagles... migratory bird abatement permit. On January 12, 2007, we published a Federal Register notice (72 FR...

  10. 26 CFR 1.507-9 - Abatement of taxes.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 26 Internal Revenue 7 2011-04-01 2009-04-01 true Abatement of taxes. 1.507-9 Section 1.507-9 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Private Foundations § 1.507-9 Abatement of taxes. (a) General rule....

  11. 26 CFR 1.507-9 - Abatement of taxes.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 26 Internal Revenue 7 2013-04-01 2013-04-01 false Abatement of taxes. 1.507-9 Section 1.507-9 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Private Foundations § 1.507-9 Abatement of taxes. (a) General rule....

  12. 10 CFR 851.22 - Hazard prevention and abatement.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Hazard prevention and abatement. 851.22 Section 851.22 Energy DEPARTMENT OF ENERGY WORKER SAFETY AND HEALTH PROGRAM Specific Program Requirements § 851.22 Hazard prevention and abatement. (a) Contractors must establish and implement a hazard prevention...

  13. 26 CFR 1.507-9 - Abatement of taxes.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED... Commissioner may at his discretion abate the unpaid portion of the assessment of any tax imposed by section 507... the abatement of tax imposed under section 507(c), no tax imposed under any provision of chapter...

  14. Death by paint thinner.

    PubMed

    Collison, Ines; Moorehead, Wayne

    2002-10-01

    A 38-year-old Caucasian male, reportedly missing for four days, was found dead 40 feet down a steep ravine, apparently after jumping down the cliff. Two rectangular cans of paint thinner, 1-qt and 1-gal sizes, were found in his vehicle at the top of the cliff. The autopsy report indicated that the decedent was normal except for the heart and myocardium, the lung parenchyma, and the gastric and esophageal mucosa. The stomach contents revealed a brownish liquid with a nearly clear, thick, oily film, and the small and large bowels showed oily liquid with a strong odor of a petroleum distillate. Toxicological analysis was negative for ethanol and common drugs of abuse. Valproic acid, diphenhydramine, and norsertraline where found in therapeutic concentrations, and sertraline, diazepam, and nordiazepam were found in subtherapeutic levels. Bupropion metabolites were also detected. Static adsorption-elution, commonly used in fire debris analysis, was used to examine the brain, liver, lung, blood, and urine. A liquid-liquid extraction was performed on the vitreous humor. The stomach contents and samples from the paint thinner cans were diluted with carbon disulfide. All but the blood and vitreous contained a medium petroleum distillate. The stomach content was consistent with the liquid from the one-gallon can. Chromatograms suggest differential metabolism and/or distribution among the different organs. PMID:12423013

  15. Microscale radiocarbon dating of paintings

    NASA Astrophysics Data System (ADS)

    Hendriks, Laura; Hajdas, Irka; McIntyre, Cameron; Küffner, Markus; Scherrer, Nadim C.; Ferreira, Ester S. B.

    2016-03-01

    In this paper, radiocarbon dating of paintings using minimal sample sizes has been investigated, in an effort to address the problem of limited access to sample material in paintings. 14C analyses were conducted on signed and dated paintings from two Swiss artists of the twentieth century. The selected paintings dated from the 1930s and 1960s, provided the opportunity to evaluate the dating accuracy on paintings realized before and after 1950 AD when the 14C bomb peak was created, as a result of the nuclear tests conducted in the 1950/1960s. The work focused on the one hand on minimizing the size of the canvas sample required for accelerator mass spectrometer radiocarbon measurement on the gas ion source of the MICADAS and, on the other hand, on testing the possibility of dating the organic binder of the paint. Following careful characterization of the paint composition by X-ray fluorescence spectroscopy, Fourier transformed infrared spectroscopy, and Raman spectroscopy, paints containing no other carbon source than the natural organic binder were identified and dated.

  16. Additive Transforms Paint into Insulation

    NASA Technical Reports Server (NTRS)

    2007-01-01

    Tech Traders Inc. sought assistance developing low-cost, highly effective coatings and paints that created useful thermal reflectance and were safe and non-toxic. In cooperation with a group of engineers at Kennedy Space Center., Tech Traders created Insuladd, a powder additive made up of microscopic, inert gas-filled, ceramic microspheres that can be mixed into ordinary interior or exterior paint, allowing the paint to act like a layer of insulation. When the paint dries, this forms a radiant heat barrier, turning the ordinary house paint into heat-reflecting thermal paint. According to Tech Traders, the product works with all types of paints and coatings and will not change the coverage rate, application, or adhesion of the paint. Other useful applications include feed storage silos to help prevent feed spoilage, poultry hatcheries to reduce the summer heat and winter cold effects, and on military vehicles and ships. Tech Traders has continued its connection to the aerospace community by recently providing Lockheed Martin Corporation with one of its thermal products for use on the F-22 Raptor.

  17. Structure development in magnetic paints

    SciTech Connect

    Potanin, A.A.; Shrauti, S.M.; Lane, A.M.; Arnold, D.W.

    1996-12-31

    Dynamic rheological measurements are used to probe the structure of model magnetic paints which contain ferro-magnetic particles of iron oxide or barium ferrite a wetting resin and a solvent. Along with industrially used organic solvent-based paints, water-borne systems are studied. Methods to characterize the dispersion quality of pigment particles through rheological measurements are outlined.

  18. Laser assisted graffiti paints removing

    NASA Astrophysics Data System (ADS)

    Novikov, B. Y.; Chikalev, Y. V.; Shakhno, E. A.

    2010-07-01

    It's hard to imagine a modern city view without some drawings and inscriptions, usually called "graffiti". Traditional cleaning methods do not suit modern requirements. Investigation of possibilities of laser assisted paints removing is described in this article. The conditions for removing different paints from different surfaces were defined.

  19. Laser assisted graffiti paints removing

    NASA Astrophysics Data System (ADS)

    Novikov, B. Y.; Chikalev, Y. V.; Shakhno, E. A.

    2011-02-01

    It's hard to imagine a modern city view without some drawings and inscriptions, usually called "graffiti". Traditional cleaning methods do not suit modern requirements. Investigation of possibilities of laser assisted paints removing is described in this article. The conditions for removing different paints from different surfaces were defined.

  20. Lead Paint Exposure Assessment in High Bays of Johnson Space Center

    NASA Technical Reports Server (NTRS)

    Stanch, Penney; Plaza, Angel; Keprta, Sean

    2008-01-01

    This slide presentation reviews the program to assess the possibility of lead paint exposure in the high bays of some of the Johnson Space Center buildings. Some of the buildings in the Manned Space Flight Center (MSC) were built in 1962 and predate any considerations to reduce lead in paints and coatings. There are many of these older buildings that contain open shops and work areas that have open ceilings, These shops include those that had operations that use leaded gasoline, batteries, and lead based paints. Test were planned to be conducted in three phases: (1) Surface Dust sampling, (2) personal exposure montioring, and (3) Ceiling paint Sampling. The results of the first two phases were reviewed. After considering the results of the first two phases, and the problems associated with the retrieval of samples from high ceilings, it was determined that the evaluation of ceiling coatings would be done on a project by project and in response to a complaint.

  1. Painting in space

    NASA Astrophysics Data System (ADS)

    Brody, Arthur W.; Hartman, Chris

    2001-06-01

    The goal of our research is to enable artists to interact with the world of their imagination; to create art by moving, molding, and shaping virtual forms as if by their own bodies. We show a print that represents a scene painted into virtual reality and tell how the scene and the subsequent print were done. There will be some discussion of the meaning of the work, the intent of the artist and the relationship between the art and the technology used to create it. The print seen here is both a picture of an exotic place and the artistic fruit of research into how to embody the user in virtual reality. Our approach is based on the premise that embodiment is an appropriate direction for developing tools to facilitate artistic expression. It is also a premise of this research that the constraints requisite to creating art will also result in tools that serve the visualization community in general.

  2. The levelling of paint films

    NASA Astrophysics Data System (ADS)

    Wilson, S. K.

    1993-01-01

    Using a brush to apply paint to a flat surface almost inevitably means that the bristles of the brush leave behind an uneven paint surface. As the paint dries out, these non-uniformities tend to flatten out to leave a protective and aesthetically pleasing even coating; however, experiments have shown that some solvent-based high-gloss alkyd paints can exhibit more unusual behaviour as they dry. In these experiments the initial rate of levelling was faster than that expected simply due to constant surface tension effects, and, much more unexpectedly, over a timescale of a few minutes the peaks of the original disturbance became troughs and vice versa. In this paper the author presents a mathematical model for the drying of a layer of solvent-based high-gloss alkyd paint and analyses the linear stability of a uniform layer of paint subject to an initial perturbation representing the marks left by a paint brush. Investigating the model highlights the crucial role played by solvent evaporation and leads to a plausible physical explanation of the observed phenomena. Furthermore, the analytical and numerical predictions of the model are found to be in good quantitative agreement with the experimental results.

  3. Electrically Conductive Paints for Satellites

    NASA Technical Reports Server (NTRS)

    Gilligan, J. E.; Wolf, R. E.; Ray, C.

    1977-01-01

    A program was conducted to develop and test electrically conductive paint coatings for spacecraft. A wide variety of organic and inorganic coatings were formulated using conductive binders, conductive pigments, and similar approaches. Z-93, IITRI's standard specification inorganic thermal control coating, exhibits good electrical properties and is a very space-stable coating system. Several coatings based on a conductive pigment (antimony-doped tin oxide) in silicone and silicate binders offer considerable promise. Paint systems using commercially available conductive polymers also appear to be of interest, but will require substantial development. Evaluations were made based on electrical conductivity, paint physical properties, and the stability of spectral reflectance in space environment testing.

  4. 7 CFR 3201.106 - Paint removers.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 15 2014-01-01 2014-01-01 false Paint removers. 3201.106 Section 3201.106 Agriculture... Items § 3201.106 Paint removers. (a) Definition. Products formulated to loosen and remove paint from painted surfaces. (b) Minimum biobased content. The Federal preferred procurement product must have...

  5. 49 CFR 173.173 - Paint, paint-related material, adhesives, ink and resins.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 2 2014-10-01 2014-10-01 false Paint, paint-related material, adhesives, ink and... Than Class 1 and Class 7 § 173.173 Paint, paint-related material, adhesives, ink and resins. (a) When..., paint-related material, adhesives, ink and resins must be packaged as follows: (1) As prescribed...

  6. 49 CFR 173.173 - Paint, paint-related material, adhesives, ink and resins.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 2 2013-10-01 2013-10-01 false Paint, paint-related material, adhesives, ink and... Than Class 1 and Class 7 § 173.173 Paint, paint-related material, adhesives, ink and resins. (a) When..., paint-related material, adhesives, ink and resins must be packaged as follows: (1) As prescribed...

  7. 49 CFR 173.173 - Paint, paint-related material, adhesives, ink and resins.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 2 2012-10-01 2012-10-01 false Paint, paint-related material, adhesives, ink and... Than Class 1 and Class 7 § 173.173 Paint, paint-related material, adhesives, ink and resins. (a) When..., paint-related material, adhesives, ink and resins must be packaged as follows: (1) As prescribed...

  8. 49 CFR 173.173 - Paint, paint-related material, adhesives, ink and resins.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... name for paint, lacquer, enamel, stain, shellac, varnish, liquid aluminum, liquid bronze, liquid gold... 49 Transportation 2 2010-10-01 2010-10-01 false Paint, paint-related material, adhesives, ink and... Than Class 1 and Class 7 § 173.173 Paint, paint-related material, adhesives, ink and resins. (a)...

  9. 49 CFR 173.173 - Paint, paint-related material, adhesives, ink and resins.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... name for paint, lacquer, enamel, stain, shellac, varnish, liquid aluminum, liquid bronze, liquid gold... 49 Transportation 2 2011-10-01 2011-10-01 false Paint, paint-related material, adhesives, ink and... Than Class 1 and Class 7 § 173.173 Paint, paint-related material, adhesives, ink and resins. (a)...

  10. Paint removal activities in Canada

    NASA Astrophysics Data System (ADS)

    Foster, Terry

    1993-03-01

    Paint removal activities currently under way in Canada include: research and development of laser paint stripping; development and commercialization of a new blasting medium based on wheat starch; commercialization of a new blasting medium and process using crystalline ice blasting for paint removal and surface cleaning; and the development of automated and robotic systems for paint stripping applications. A specification for plastic media blasting (PMB) of aircraft and aircraft components is currently being drafted by NDHQ for use by the Canadian Armed Forces (CAF) and contractors involved in coating removal for the CAF. Defense Research Establishment Pacific (DREP) is studying the effects of various blast media on coating removal rates, and minimizing the possibility of damage to substrates other than aluminum such as graphite epoxy composite and Kevlar. The effects of plastic media blasting on liquid penetrant detection of fatigue cracks is also under investigation.

  11. Studying Landforms through Landscape Painting.

    ERIC Educational Resources Information Center

    Glenn, William H.

    1981-01-01

    Using three specific works of art, the author demonstrates how a study of selected landscape paintings can be integrated into units on landforms in secondary school earth science and general science courses. (Author/SJL)

  12. A Comparison of Lead Abatement Technologies at Lewis Research Center

    NASA Technical Reports Server (NTRS)

    Jeziorowski, Luz Y.; Calla, Joanne

    1997-01-01

    In 1995, Lewis participated in a pilot test of Lead Specifications. The Specifications were sponsored by the Center to Protect Worker's Rights (CPWR). Entitled "Model Specifications for the Protection of Worker's from Lead on Steel Structures", one aspect of this endeavor was to test and compare several lead abatement technologies. The project overview, objectives, team, and requirements as well as abatement methods and materials are outlined.

  13. Overview of paint removal methods

    NASA Astrophysics Data System (ADS)

    Foster, Terry

    1995-04-01

    With the introduction of strict environmental regulations governing the use and disposal of methylene chloride and phenols, major components of chemical paint strippers, there have been many new environmentally safe and effective methods of paint removal developed. The new methods developed for removing coatings from aircraft and aircraft components include: mechanical methods using abrasive media such as plastic, wheat starch, walnut shells, ice and dry ice, environmentally safe chemical strippers and paint softeners, and optical methods such as lasers and flash lamps. Each method has its advantages and disadvantages, and some have unique applications. For example, mechanical and abrasive methods can damage sensitive surfaces such as composite materials and strict control of blast parameters and conditions are required. Optical methods can be slow, leaving paint residues, and chemical methods may not remove all of the coating or require special coating formulations to be effective. As an introduction to environmentally safe and effective methods of paint removal, this paper is an overview of the various methods available. The purpose of this overview is to introduce the various paint removal methods available.

  14. Field characterization of external grease abatement devices.

    PubMed

    Aziz, Tarek N; Holt, Leon M; Keener, Kevin M; Groninger, John W; Ducoste, Joel J

    2012-03-01

    This study characterized some of the physical and chemical features of large outside field grease abatement devices (GADs). 24-hour measurements of several food service establishments' (FSEs') influent GAD flowrates indicated highly intermittent conditions with hydraulic retention times (HRTs) that exceeded the common recommendation (30 minutes) by two to five times. Investigation into the chemical characteristics of GADs indicated highly variable influent and effluent fat, oil, and grease (FOG) concentrations. Low pH and dissolved oxygen values were measured throughout the GAD, indicating the likely occurrence of anaerobic microbial processes. Detailed spatial and temporal observations of the accumulation of FOG and food solids were also discussed. Though the FOG layer remained relatively constant for all GAD configurations investigated, results indicated that commonly-used GAD configurations with a straight submerged inlet tee or no-inlet tee configuration may result in the transport of food solids into the second compartment. The present research showed increased accumulation of food solids in the first compartment with a retro-fit flow distributive inlet. This retro-fit displays promise for potentially improving the separation characteristics of existing GADs.

  15. The Veterans Administration's Asbestos Abatement Program

    SciTech Connect

    Schepers, G.W. )

    1991-12-31

    The Veterans Administration has developed a program of asbestos abatement for its more than 1000 buildings, where health care personnel from 173 hospitals and 238 ambulatory care clinics are likely to encounter respirable asbestos. This is a costly program, which has averaged about $25 million annually for the past ten years. The VA has banned the use of new asbestos products containing more than 1% of asbestos in building construction or renovation projects. Industrial hygiene engineering programs have been ordered instituted at all VA medical centers to monitor dust levels in compliance with OSHA and EPA requirements. Health surveillance programs, managed by an environmental health physician at each medical center, have been instituted for all personnel who have been identified to have breathed asbestos fibers in excess of OSHA-EPA threshold limit values. The health care program focuses on the identification of asbestosis and asbestos-related cancer through periodic X-ray films, lung function tests, and electrocardiographic and physical examination screening. The program also stresses cessation of smoking.

  16. Painted supported lipid membranes

    PubMed Central

    Florin, E.-L.; Gaub, H. E.

    1993-01-01

    We report herein measurements on a novel type of supported lipid films, which we call painted supported membranes (PSM). These membranes are formed in a self-assembly process on alkylated gold films from an organic solution. The formation process was investigated with surface plasmon resonance microscopy. The optical and electrical properties of the films were determined for various types of lipids and as a function of temperature by means of cyclic voltammetry and potential relaxation after charge injection. We could show that these films exhibit an extraordinarily high specific resistivity which, depending on the lipid, may be as high as 109 ohm/cm2. We could also show that due to this low conductivity, an electrical polarization across the PSM relaxes with characteristic time constants of up to 20 min. The electrical properties together with their high mechanical stability and accessibility to surface sensitive techniques make these films well suitable model membranes for optical and electrical investigations. Examples for such applications are given in the subsequent article by Seifert et al. ImagesFIGURE 3FIGURE 4 PMID:19431873

  17. Lead levels in paint flakes from buildings in Nigeria: a preliminary study.

    PubMed

    Nduka, J K C; Orisakwe, O E; Maduawguna, C A

    2008-09-01

    Lead is a malleable metal previously used to improve the durability and color luster of paint applied in homes and on industrial structures such as bridges. Lead has deleterious effects on multiple organs in humans. There is paucity of information on the extent of the use of lead-based paint in Nigerian houses. This study has attempted to estimate the extent of use of lead-based paint in buildings in Eastern Nigeria using 168 buildings. Flaked paint samples were collected from residential, church, commercial, and school buildings from four most populous cities in Eastern Nigeria namely Enugu, Onitsha, Aba, and Port Harcourt, and they were digested using conc HNO(3):HCLO(4) (1:1) and analyzed using atomic absorption spectrophotometer. The lead levels from buildings in Enugu ranged from 39.385 +/- 1.111-69.843 +/- 4.886 mg/kg. The highest level of lead was found in Onitsha ranging from 49.503 +/- 0.000-74.352 +/- 0.571 mg/kg. Residential buildings, which mainly serve the under privileged populations, has the highest lead level in this study. In Aba, the highest lead level (66.432 +/- 0.013 mg/kg) was found in commercial buildings aged 5-10 years. The lead levels in paint flakes from buildings in the four cities tended to decrease with increasing age of the buildings. Taken together all the building paint flakes from the four cities had lead levels higher than the United States Environmental Protection Agency permissible level of 5 mg/kg. There is a need for primary intervention strategy to reduce the paint lead levels in Nigeria.

  18. Microbial evaluation and deterioration of paints and paint-products.

    PubMed

    Obidi, O F; Aboaba, O O; Makanjuola, M S; Nwachukwu, S C U

    2009-09-01

    The microbial quality of materials and final products of a reputable paint industry in Lagos area were analysed. The bacterial contaminants isolated in the paint-products included Bacillus brevis, B. polymyxa, B. laterosporus, Lactobacillus gasseri, L. brevis, Escherichia coli and Proteus mirabilis. The fungal contaminants detected in the paints were mainly Aspergillus niger, A. flavus and Penicillium citrinum. The microbial populations in the raw materials ranged from 1.0 x 10(6) - 9.5 x 10(6) cfu g(-1) for bacteria and between 1.25 x 10(4) and 6.8 x 10(4) cfu g(-1) for fungi while those present in packaging materials ranged from 3.45 x 10(6) - 7.65 x 10(6) cfu g(-1) for bacteria and 2.4 x 10(3) - 2.8 x 10(3) cfu g(-1) for fungi respectively. The bacterial populations in the fresh paint samples monitored every two weeks from the time of production ranged from 1.6 x 10(1) - 4.7 x 10(5) cfu ml(-1) while the fungal populations ranged from 1.0 x 10(1) - 5.5 x 10(3) cfu ml(-1) over a ten-month study period. The optical density at 600 nm increased while transmittance, pH, specific gravity and viscosity of the paint samples decreased over the period suggesting gradual deterioration of the aesthetic qualities of the paint-products with time as indicated by the measured parameters.

  19. Ultraviolet-radiation-curable paints

    SciTech Connect

    Grosset, A M; Su, W F.A.; Vanderglas, E

    1981-09-30

    In product finishing lines, ultraviolet radiation curing of paints on prefabricated structures could be more energy efficient than curing by natural gas fired ovens, and could eliminate solvent emission. Diffuse ultraviolet light can cure paints on three dimensional metal parts. In the uv curing process, the spectral output of radiation sources must complement the absorption spectra of pigments and photoactive agents. Photosensitive compounds, such as thioxanthones, can photoinitiate unsaturated resins, such as acrylated polyurethanes, by a free radical mechanism. Newly developed cationic photoinitiators, such as sulfonium or iodonium salts (the so-called onium salts) of complex metal halide anions, can be used in polymerization of epoxy paints by ultraviolet light radiation. One-coat enamels, topcoats, and primers have been developed which can be photoinitiated to produce hard, adherent films. This process has been tested in a laboratory scale unit by spray coating these materials on three-dimensional objects and passing them through a tunnel containing uv lamps.

  20. Painting in the Year 2000: A Classroom Video Series.

    ERIC Educational Resources Information Center

    Szekely, George

    2000-01-01

    Focuses on a video series showing elementary students discovering new approaches to painting. Describes performances and questions that expand children's views on painting, including painting objects, seeing different ideas for the canvas, and exploring new paint brush forms. (CMK)

  1. Global forestry emission projections and abatement costs

    NASA Astrophysics Data System (ADS)

    Böttcher, H.; Gusti, M.; Mosnier, A.; Havlik, P.; Obersteiner, M.

    2012-04-01

    In this paper we present forestry emission projections and associated Marginal Abatement Cost Curves (MACCs) for individual countries, based on economic, social and policy drivers. The activities cover deforestation, afforestation, and forestry management. The global model tools G4M and GLOBIOM, developed at IIASA, are applied. GLOBIOM uses global scenarios of population, diet, GDP and energy demand to inform G4M about future land and commodity prices and demand for bioenergy and timber. G4M projects emissions from afforestation, deforestation and management of existing forests. Mitigation measures are simulated by introducing a carbon tax. Mitigation activities like reducing deforestation or enhancing afforestation are not independent of each other. In contrast to existing forestry mitigation cost curves the presented MACCs are not developed for individual activities but total forest land management which makes the estimated potentials more realistic. In the assumed baseline gross deforestation drops globally from about 12 Mha in 2005 to below 10 Mha after 2015 and reach 0.5 Mha in 2050. Afforestation rates remain fairly constant at about 7 Mha annually. Although we observe a net area increase of global forest area after 2015 net emissions from deforestation and afforestation are positive until 2045 as the newly afforested areas accumulate carbon rather slowly. About 200 Mt CO2 per year in 2030 in Annex1 countries could be mitigated at a carbon price of 50 USD. The potential for forest management improvement is very similar. Above 200 USD the potential is clearly constrained for both options. In Non-Annex1 countries avoided deforestation can achieve about 1200 Mt CO2 per year at a price of 50 USD. The potential is less constrained compared to the potential in Annex1 countries, achieving a potential of 1800 Mt CO2 annually in 2030 at a price of 1000 USD. The potential from additional afforestation is rather limited due to high baseline afforestation rates assumed

  2. Paint, lacquer, and varnish remover poisoning

    MedlinePlus

    Paint remover poisoning ... Paint lacquer and varnish remover poisoning can cause symptoms in various parts of the body. AIRWAYS AND LUNGS Breathing difficulty (from inhalation) Throat swelling (may also cause ...

  3. Miniature Paintings: Small Size, Big Impact!

    ERIC Educational Resources Information Center

    Hicks, Bill

    2011-01-01

    This article describes a miniature painting project that allows students to research a master painter and then replicate the work on a smaller scale. This lesson focuses on the students' ability to learn to identify style, subject matter, themes, and content in painting through the study of historical paintings, and the application of various…

  4. EMISSIONS OF ODOROUS ALDEHYDES FROM ALKYD PAINT

    EPA Science Inventory

    Aldehyde emissions are widely held responsible for the acrid after-odor of drying alkyd-based paint films. The aldehyde emissions from three different alkyd paints were measured in small environmental chambers. It was found that, for each alkyd paint applied, more than 2 mg of ...

  5. Drawing and Painting with Under-Threes.

    ERIC Educational Resources Information Center

    Kolbe, Ursula; Smyth, Jane

    2000-01-01

    Noting that drawing and painting offer very young children powerful ways to explore and communicate thoughts and feelings, this booklet for caregivers and teachers offers suggestions related to painting and drawing for children under 3 years. The booklet discusses what young children can do with drawing and painting materials, including exploring…

  6. Mural Painting as Inclusive Art Learning Experience

    ERIC Educational Resources Information Center

    Ho, Kong

    2010-01-01

    Traditional art education, like other academic disciplines, emphasizes competitiveness and individualism. Through a mural painting curriculum, learners participate in mural art and history appreciation, are active in mural theme or content construction, and engage in hands-on mural design and painting processes. When mural paintings are produced…

  7. Bringing Art to Life through Living Paintings

    ERIC Educational Resources Information Center

    Stillwagon, Joanne

    2005-01-01

    In this article, the author relates how she and other art teachers developed a "living painting" lesson, an art lesson that incorporates art history and painting. The lesson was developed also in part to help new student-teachers plan a memorable lesson. With the living painting lesson, students will have to choose and recreate famous paintings…

  8. Environmental projects. Volume 1: Polychlorinated biphenyl (PCB) abatement program

    NASA Technical Reports Server (NTRS)

    Kushner, L.

    1987-01-01

    Six large parabolic dish antennas are located at the Goldstone Deep Space Communications Complex north of Barstow, California. Some of the ancillary electrical equipment of thes Deep Space Stations, particularly transformers and power capicitors, were filled with stable, fire-retardant, dielectric fluids containing substances called polychlorobiphenyls (PCBs). Because the Environmental Protection Agency has determined that PCBs are environmental pollutants toxic to humans, all NASA centers have been asked to participate in a PCB-abatement program. Under the supervision of JPL's Office of Telecommunications and Data Acquisition, a two-year long PCB-abatement program has eliminated PCBs from the Goldstone Complex.

  9. Chicanos Paint Their Way Back.

    ERIC Educational Resources Information Center

    Treguer, Annick

    1999-01-01

    In Tucson (Arizona) and El Paso (Texas), Chicano mural painters and art educators have begun community programs to engage alienated Chicano and Yaqui youth in painting murals that defuse gang conflicts, celebrate Mexican culture and history, and provide training in marketable skills. (SV)

  10. Stop and Paint the Flowers.

    ERIC Educational Resources Information Center

    Phillips, Shelley

    2002-01-01

    Describes an art lesson where students used watercolors to paint a flower bouquet arranged in a vase. Explains that the students viewed examples of flower bouquets by artists such as Vincent van Gogh and Odilon Redon. Discusses, in detail, the process of creating the artworks. (CMK)

  11. Controlling Color in Oil Painting.

    ERIC Educational Resources Information Center

    Amorino, Joseph

    1990-01-01

    Explains how a veil control method allows secondary students to use oil paints in the classroom without difficulties of control, manageability, and clean up. Outlines how to prepare and apply oil glazes. Maintains that this method enhances students' studio skills and helps them appreciate the works of the great masters. (KM)

  12. Paint the World with Light

    ERIC Educational Resources Information Center

    Gran, David

    2010-01-01

    Two classrooms on opposite sides of the world happened to be working on a very similar project at the same time. In both Shanghai, China, and Palm Springs, California, students were learning how to turn their flashlights and other light-emitting objects into paintbrushes. Light painting is a form of long-exposure photography in which the shutter…

  13. But when was it painted?

    NASA Astrophysics Data System (ADS)

    Lundstad, E.; Woll, G.

    2009-04-01

    The Munch Museum, Oslo, Norway, is dedicated to the visual works of the famous Norwegian painter Edvard Munch (1863 - 1944). Edvard Munch was a symbolist, expressionist painter and printmaker from Oslo, Norway. He was regarded as the pioneer of the amazing Expressionist movement. His art work from the late 1800's is the most well known, but his later work is gradually attracting more attention and is quite an inspiration of many of today's artists. The Munch Museum catalogue for 2008 contains about 1700 paintings of which virtually very few have a precise date. Even when the artist has written the year on the painting itself, there may be a significant uncertainty about this date, and partly due to unclear writing making it difficult to interpret the numbers. This means that other sources need to be applied to verify an accurate date. The climatologist at the Norwegian Meteorological Institute can help dating paintings of Munch. E. g. the painting "Standing Woman with Arms Folded". The painting shows a woman in front of a hill with much snow. The location is almost certainty Grimsrød on Jeløya, a property Munch began renting on March 1, 1913. Jeløya is an island at the southeastcoast of Norway near the town Moss. Jeløya has usually not so much snow because it is near by the sea and windy. The last digit in the date is unclear and has been read as both '3' and '5'. The woman in the portrait, Ingeborg Kaurin, was Munch's model up to the beginning of 1915, so both dates are possible. The year written on the painting has been read as both 1913 and 1915, and since 1974 it has usually been interpreted as 1913 (Stenersensamlingen's catalogue 1974). In the project "But when was it painted?" disclose that it could be another year. One way to reconsider when a painting was painted is to study geophysical characteristics and consider historical observations of snow. The method that is used here is to study daily meteorological snow data from this period from the

  14. 23 CFR 772.9 - Analysis of traffic noise impacts and abatement measures.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 23 Highways 1 2010-04-01 2010-04-01 false Analysis of traffic noise impacts and abatement measures... AND ENVIRONMENT PROCEDURES FOR ABATEMENT OF HIGHWAY TRAFFIC NOISE AND CONSTRUCTION NOISE § 772.9 Analysis of traffic noise impacts and abatement measures. (a) The highway agency shall determine...

  15. 23 CFR 772.9 - Analysis of traffic noise impacts and abatement measures.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 23 Highways 1 2011-04-01 2011-04-01 false Analysis of traffic noise impacts and abatement measures... AND ENVIRONMENT PROCEDURES FOR ABATEMENT OF HIGHWAY TRAFFIC NOISE AND CONSTRUCTION NOISE § 772.9 Analysis of traffic noise impacts and abatement measures. (a) The highway agency shall determine...

  16. Marginal abatement cost curves for NOx incorporating both controls and alternative measures

    EPA Science Inventory

    A marginal abatement cost curve (MACC) traces out the efficient marginal abatement cost level for any aggregate emissions target when a least cost approach is implemented. In order for it to represent the efficient MAC level, all abatement opportunities across all sectors and loc...

  17. Marginal abatement cost curve for NOx incorporating controls, renewable electricity, energy efficiency and fuel switching

    EPA Science Inventory

    A marginal abatement cost curve (MACC) traces out the relationship between the quantity of pollution abated and the marginal cost of abating each additional unit. In the context of air quality management, MACCs typically are developed by sorting end-of-pipe controls by their resp...

  18. Noise levels near streets, effectiveness and cost abatement measures

    NASA Technical Reports Server (NTRS)

    Lang, J.

    1980-01-01

    During the years 1975-1978, research was carried concerning the current noise levels near streets, the annoyance felt by the population, possible noise abatement measures for these streets, and the economic impact of such measures. The results of the research are summarized.

  19. 76 FR 67650 - Migratory Bird Permits; Abatement Regulations

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-02

    ... for a specific permit authorizing the use of raptors in abatement activities (76 FR 39368). The... the advance notice of proposed rulemaking, please refer to that document at 76 FR 39368 (July 6, 2011... Note Following 16 U.S.C. 703. Dated: October 21, 2011. Rachel Jacobson, Acting Assistant Secretary...

  20. Abating air pollution at negative cost via energy efficiency

    SciTech Connect

    Lovins, A.B. )

    1989-11-01

    Advanced techniques for energy end-use efficiency can pay for very large direct and indirect reductions in emissions, usually with money left over. This permits much more complete abatements than are often analyzed, and not at a cost but at a large profit. The order of economic priority, however, is also the order of environmental priority. Choosing the best buys first maximizes abatement per dollar; Choosing anything else first thus reduces abatement per dollar. To achieve the largest, fastest abatement therefore requires that the Chinese-restaurant-menu approach to energy investments-buying one option from Column A, one from Column B, etc., until all constituencies are satisfied-give way to the least-cost approach that is now the expressed (if less often the observed) policy of utility regulations in more than 40 states. The powerful supply-curve method of identifying priorities is therefore valid only if pollution prevention is considered together with, and allowed to precede and even to displace as well as augment, the more traditional end-of-pipe technologies.

  1. Contracting for Asbestos Abatement: What You Need to Know.

    ERIC Educational Resources Information Center

    Bittle, Edgar H.; McAllister, Jane B.

    1990-01-01

    School districts are required to determine if asbestos-containing materials exist at school facilities and design and implement asbestos abatement. Reviews how to select a contractor, draft the contract, and ensure its proper implementation by complying with the law and avoiding liability. (MLF)

  2. Novel paint design based on nanopowder to protection against X and gamma rays

    PubMed Central

    Movahedi, Mohammad Mehdi; Abdi, Adibe; Mehdizadeh, Alireza; Dehghan, Naser; Heidari, Emad; Masumi, Yusef; Abbaszadeh, Mojtaba

    2014-01-01

    Background: Lead-based shields are the standard method of intraoperative radiation protection in the radiology and nuclear medicine department. Human lead toxicity is well documented. The lead used is heavy, lacks durability, is difficult to launder, and its disposal is associated with environmental hazards. The aim of this study was to design a lead free paint for protection against X and gamma rays. Materials and Methods: In this pilot st we evaluated several types of nano metal powder that seemed to have good absorption. The Monte Carlo code, MCNP4C, was used to model the attenuation of X-ray photons in paints with different designs. Experimental measurements were carried out to assess the attenuation properties of each paint design. Results: Among the different nano metal powder, nano tungsten trioxide and nano tin dioxide were the two most appropriate candidates for making paint in diagnostic photon energy range. Nano tungsten trioxide (15%) and nano tin dioxide (85%) provided the best protection in both simulation and experiments. After this step, attempts were made to produce appropriate nano tungsten trioxide-nano tin dioxide paints. The density of this nano tungsten trioxide-nano tin dioxide paint was 4.2 g/cm3. The MCNP simulation and experimental measurements for HVL (Half-Value Layer) values of this shield at 100 kVp were 0.25 and 0.23 mm, respectively. Conclusions: The results showed the cost-effective lead-free paint can be a great power in absorbing the X-rays and gamma rays and it can be used instead of lead. PMID:24591777

  3. Neighborhood level health risk assessment of lead paint removal activities from elevated steel bridges

    SciTech Connect

    Conway, R.F.; Cohen, J.T.; Bowers, T.

    1999-07-01

    The New York City Department of Transportation (NYCDOT) has adopted strict containment and monitoring procedures during paint removal activities on its bridges because of the increasing awareness about lead poisoning in children in urban environments and the potential risk of lead-based paint releases during those activities. NYCDOT owns nearly 800 bridges scattered throughout New York City. Before undertaking paint removal activities as part of its ongoing preventive maintenance and rehabilitation program, NYCDOT recently conducted an analysis to determine the public health risk posed to children living near them. The analysis the first of its kind to assess the actual public health risk potential during both routine operations and upset conditions, or accidental releases evaluated the total and incremental blood lead levels from paint removal activities on more than 5,000 children from 6 months to 6 years old. Increases in baseline blood lead levels were estimated using several models, including EPA's Integrated Exposure Uptake Biokinetic (IEUBK) Model. This model estimates steady-state blood lead levels in children, reflecting exposure to lead in multiple media over an extended period of time. Increases in lead exposure from paint removal activities in the area surrounding the bridges was estimated using EPA's Industrial Source Complex (ISC3) model to calculate ambient air and deposition levels. Potential releases from the containment and ancillary equipment used in the paint removal process were modeled based on different release scenarios ranging from routine operations to complete failure of containment. To estimate the paint removal activities' contribution to long-term exterior dust lead levels (and its related interior component), a stochastic simulation model was developed for each block in the study area.

  4. Using Temperature Sensitive Paint Technology

    NASA Technical Reports Server (NTRS)

    Hamner, M. P.; Popernack, T. G., Jr.; Owens, L. R.; Wahls, R. A.

    2002-01-01

    New facilities and test techniques afford research aerodynamicists many opportunities to investigate complex aerodynamic phenomena. For example, NASA Langley Research Center's National Transonic Facility (NTF) can hold Mach number, Reynolds number, dynamic pressure, stagnation temperature and stagnation pressure constant during testing. This is important because the wing twist associated with model construction may mask important Reynolds number effects associated with the flight vehicle. Beyond this, the NTF's ability to vary Reynolds number allows for important research into the study of boundary layer transition. The capabilities of facilities such as the NTF coupled with test techniques such as temperature sensitive paint yield data that can be applied not only to vehicle design but also to validation of computational methods. Development of Luminescent Paint Technology for acquiring pressure and temperature measurements began in the mid-1980s. While pressure sensitive luminescent paints (PSP) were being developed to acquire data for aerodynamic performance and loads, temperature sensitive luminescent paints (TSP) have been used for a much broader range of applications. For example, TSP has been used to acquire surface temperature data to determine the heating due to rotating parts in various types of mechanical systems. It has been used to determine the heating pattern(s) on circuit boards. And, it has been used in boundary layer analysis and applied to the validation of full-scale flight performance predictions. That is, data acquired on the same model can be used to develop trends from off design to full scale flight Reynolds number, e.g. to show the progression of boundary layer transition. A discussion of issues related to successfully setting-up TSP tests and using TSP systems for boundary layer studies is included in this paper, as well as results from a variety of TSP tests. TSP images included in this paper are all grey-scale so that similar to

  5. Color signatures in Amorsolo paintings

    NASA Astrophysics Data System (ADS)

    Soriano, Maricor N.; Palomero, Cherry May; Cruz, Larry; Yambao, Clod Marlan Krister; Dado, Julie Mae; Salvador-Campaner, Janice May

    2010-02-01

    We present the results of a two-year project aimed at capturing quantifiable color signatures of oil paintings of Fernando Amorsolo, the Philippine's first National Artists. Color signatures are found by comparing CIE xy measurements of skin color in portraits and ground, sky and foliage in landscapes. The results are compared with results of visual examination and art historical data as well as works done by Amorsolo's contemporaries and mentors.

  6. [Burns caused by paint thinner].

    PubMed

    Benbrahim, A; Jerrah, H; Diouri, M; Bahechar, N; Boukind, E H

    2009-12-31

    Flame deriving from paint thinner is not a rare cause of burns in Morocco and we thus considered it useful to conduct an epidemiological survey of paint thinner flame burns (PTFB) in the National Burns Centre (NBC) in the Ibn-Rochd University Hospital Centre in Casablanca, Morocco. The research covered the 10-month period from September 2007 to June 2008.The aim of our work was to present the characteristic features of such burns in order to prevent them by increasing public knowledge regarding the risks involved in using paint thinner, i.e. burns in particular. During the period in question, we colligated 17 cases of PTFB out of a total number of 356 patients admitted to the NBC for acute burns of all aetiologies. The patients' average was 32 yr and they were nearly all male (16 men/1 woman), with past histories of drug addiction and/or delinquency. They were all of low-level socioeconomic class and lived mainly in shanty towns. The burn was often secondary to street violence (92% of the cases).The mean burn surface area was 23% and the burns were often deep and located mainly in the upper limbs and the trunk. PMID:21991179

  7. Potential Cost-Effective Opportunities for Methane Emission Abatement

    SciTech Connect

    Warner, Ethan; Steinberg, Daniel; Hodson, Elke; Heath, Garvin

    2015-08-01

    The energy sector was responsible for approximately 84% of carbon dioxide equivalent (CO2e) greenhouse gas (GHG) emissions in the U.S. in 2012 (EPA 2014a). Methane is the second most important GHG, contributing 9% of total U.S. CO2e emissions. A large portion of those methane emissions result from energy production and use; the natural gas, coal, and oil industries produce approximately 39% of anthropogenic methane emissions in the U.S. As a result, fossil-fuel systems have been consistently identified as high priority sectors to contribute to U.S. GHG reduction goals (White House 2015). Only two studies have recently attempted to quantify the abatement potential and cost associated with the breadth of opportunities to reduce GHG emissions within natural gas, oil, and coal supply chains in the United States, namely the U.S. Environmental Protection Agency (EPA) (2013a) and ICF (2014). EPA, in its 2013 analysis, estimated the marginal cost of abatement for non-CO2 GHG emissions from the natural gas, oil, and coal supply chains for multiple regions globally, including the United States. Building on this work, ICF International (ICF) (2014) provided an update and re-analysis of the potential opportunities in U.S. natural gas and oil systems. In this report we synthesize these previously published estimates as well as incorporate additional data provided by ICF to provide a comprehensive national analysis of methane abatement opportunities and their associated costs across the natural gas, oil, and coal supply chains. Results are presented as a suite of marginal abatement cost curves (MACCs), which depict the total potential and cost of reducing emissions through different abatement measures. We report results by sector (natural gas, oil, and coal) and by supply chain segment - production, gathering and boosting, processing, transmission and storage, or distribution - to facilitate identification of which sectors and supply chain

  8. Robotic sensors for aircraft paint stripping

    NASA Astrophysics Data System (ADS)

    Weniger, Richard J.

    1990-10-01

    Aircraft of all types need to have paint routinely removed from their outer surfaces. Any method needs to be controlled to remove all the paint and not damage the surface of the aircraft. Human operators get bored with the monotonous task of stripping paint from an aircraft and thus do not control the process very well. This type of tedious operation tends itself to robotics. A robot that strips paint from aircraft needs to have feedback as to the state of the stripping process, its location in respect to the aircraft, and the availability of stripping material. This paper describes the sensors used on the paint stripping robot being developed for the United States Air Force's Manufacturing Technology Program. Particular attention is given to the paint sensor which is the feedback element for determining the state of the stripping process.

  9. Ejecta production mechanisms on painted surfaces

    NASA Astrophysics Data System (ADS)

    Bariteau, Muriel; Mandeville, Jean-Claude; Schäfer, Frank

    2001-10-01

    Painted surfaces are frequently used on space vehicles, whether on satellites or on rocket bodies. A bibliographic research allows us to evaluate the painted surfaces in orbit at about 63000 m2. The observation of impacts on painted surfaces of the LDEF satellite shows that the total ejected mass is large. However, no description of hypervelocity impact tests on painted surfaces has been found in the literature. An ejecta model has been previously developed at ONERA/DESP. This model is applicable for hypervelocity impacts on homogeneous ductile targets, homogeneous brittle targets and solar cells. The objective of this work is to extend this model to the case of painted surfaces. Consequently, impact pictures on painted surfaces of LDEF were analysed and some laboratory impact tests were performed at the Ernst-Mach-Institut, in Freiburg, under an ESA contract.

  10. 24 CFR 3280.814 - Painting of wiring.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 24 Housing and Urban Development 5 2014-04-01 2014-04-01 false Painting of wiring. 3280.814... Painting of wiring. During painting or staining of the manufactured home, it shall be permitted to paint... cable. Some arrangement, however, shall be made so that no paint shall be applied to the...

  11. 24 CFR 3280.814 - Painting of wiring.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 24 Housing and Urban Development 5 2013-04-01 2013-04-01 false Painting of wiring. 3280.814... Painting of wiring. During painting or staining of the manufactured home, it shall be permitted to paint... cable. Some arrangement, however, shall be made so that no paint shall be applied to the...

  12. 24 CFR 3280.814 - Painting of wiring.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 24 Housing and Urban Development 5 2011-04-01 2011-04-01 false Painting of wiring. 3280.814... Painting of wiring. During painting or staining of the manufactured home, it shall be permitted to paint... cable. Some arrangement, however, shall be made so that no paint shall be applied to the...

  13. 24 CFR 3280.814 - Painting of wiring.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 24 Housing and Urban Development 5 2012-04-01 2012-04-01 false Painting of wiring. 3280.814... Painting of wiring. During painting or staining of the manufactured home, it shall be permitted to paint... cable. Some arrangement, however, shall be made so that no paint shall be applied to the...

  14. 24 CFR 3280.814 - Painting of wiring.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Painting of wiring. 3280.814... Painting of wiring. During painting or staining of the manufactured home, it shall be permitted to paint... cable. Some arrangement, however, shall be made so that no paint shall be applied to the...

  15. Paint Scaler. Innovative Technology Summary Report

    SciTech Connect

    2000-06-01

    The Paint Scaler can collect paint samples quickly and efficiently for lab analysis. The Rotary Hammer Drill is a 24-V battery operated, 3/4-in. rotary hammer drill. When used with an optional chipping adapter, the Bosch Rotary Hammer Drill can be used to perform chipping and chiseling tasks such as paint removal from either concrete or metal surfaces. It is ultra-compact, lightweight with an ergonomic balanced grip. The battery operation gives the operator more flexibility during sampling activities.

  16. THE HAZARDS OF PAINTING AND VARNISHING 1965

    PubMed Central

    Piper, Robert

    1965-01-01

    A review of paint hazards is made, giving brief descriptions of methods of application in use in 1965, of paint usage according to resin base, and of paint ingredients. The most interesting and complex of these are the resin bases, which have much in common with plastics. Reference is made to some of the many minor ingredients. The problem of keeping abreast of the possible toxic effects, so that paint manufacturers and their customers may be warned and protected, will be clear. PMID:5836564

  17. Latency attention deficit: Asbestos abatement workers need us to investigate.

    PubMed

    Roelofs, Cora

    2015-12-01

    Little is known of the impact of asbestos on the health of the workers in the United States who have removed or abated asbestos from buildings following recognition of its adverse effects on health. The United States does not have a national occupational health surveillance network to monitor asbestos-related disease and, while the United States Occupational Health and Safety Administration has a strong and detailed asbestos standard, its enforcement resources are limited. A significant proportion of asbestos abatement workers are foreign-born, and may face numerous challenges in achieving safe workplaces, including lack of union representation, economic vulnerability, and inadequate training. Public health surveillance and increased and coordinated enforcement is needed to monitor the health and exposure experiences of asbestos-exposed workers. Alarming disease trends in asbestos removal workers in Great Britain suggest that, in the United States, increased public attention will be necessary to end the epidemic of asbestos-related disease. PMID:26523746

  18. Environmental projects. Volume 12: Friable asbestos abatement, GDSCC

    NASA Technical Reports Server (NTRS)

    1990-01-01

    The Goldstone Deep Space Communications Complex (GDSCC) is part of the NASA Deep Space Network, one of the world's largest and most sensitive scientific telecommunications and radio navigation networks. Activities at the GDSCC are carried out in support of six large parabolic dish antennas. These activities may give rise to a variety of environmental hazards, particularly the danger of exposure of GDSCC personnel to asbestos fibers that have been shown to be responsible for such serious ailments as asbestosis, lung cancer, and mesothelioma. Asbestos-containing materials (ACM's) were used in the construction of many of the approximately 100 buildings and structures that were built at the GDSCC during a 30-year period from the 1950s through 1980s. The friable asbestos-abatement program at the GDSCC is presented which consists of text, illustrations, and tables that describe the friable asbestos abatement carried out at the GDSCC from December 21, 1988 through May 11, 1989.

  19. Microwave plasma torch abatement of NF3 and SF6

    NASA Astrophysics Data System (ADS)

    Hong, Yong Cheol; Uhm, Han Sup; Chun, Byung Jun; Lee, Sun Ku; Hwang, Sang Kyu; Kim, Dong Su

    2006-03-01

    An atmospheric pressure microwave plasma torch as a tool for fluorinated compounds (FCs) abatement was presented. Detailed experiments were conducted on the abatement of NF3 and SF6 in terms of destruction and removal efficiency (DRE) using Fourier transform infrared (FTIR). Swirl gas, compressed air for stable plasma, was tangentially injected into the microwave plasma torch and a mixture of N2, NF3, or SF6, and C2H4 was axially injected. The DRE of 99.1% for NF3 was achieved without an additive gas at the total flow rate of 50.1 liters per minute (lpm) by applying a microwave power of 1.4kW. Also, a DRE of SF6 up to 90.1% was obtained at the total flow rate of 40.6lpm using an applied microwave power of 1.4kW. Experimental results indicate that the microwave plasma abatement device can successfully eliminate FCs in the semiconductor industry.

  20. PAINT SHOP, FIRST FLOOR, NORTHEAST CORNER OFFICE INTERIOR, LOOKING WEST. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    PAINT SHOP, FIRST FLOOR, NORTHEAST CORNER OFFICE INTERIOR, LOOKING WEST. PROJECTING WALLS WITH INFILLED ARCHES WERE PART OF ONE PAINTING BOOTH IN ORIGINAL STRUCTURE. - Southern Pacific, Sacramento Shops, Paint Shop, 111 I Street, Sacramento, Sacramento County, CA

  1. Painting with Clay Van Gogh Style.

    ERIC Educational Resources Information Center

    Skophammer, Karen

    1999-01-01

    Discusses Vincent Van Gogh's painting "Starry Night" and describes a lesson where fifth- and sixth-grade students created their own version of the artwork. Explains that the students utilized four colors of Permoplast clay, using their hands and fingers as brushes and blending tools and the clay as paint. (CMK)

  2. Products of Chemistry: Chemistry of Paint.

    ERIC Educational Resources Information Center

    Schuerman, George; Bruzan, Raymond

    1989-01-01

    Presents an overview of coatings along with paint preparation labs. Provides students with information about and methods for preparing a product that is an integral part of daily life. Gives methodology which can be used to prepare oil based and water based paints. (MVL)

  3. The Sign System in Chinese Landscape Paintings

    ERIC Educational Resources Information Center

    McMahon, Cliff G.

    2003-01-01

    Paintings emerge from a culture field and must be interpreted in relation to the net of culture. A given culture will be implicated by the sign system used by the painter. Everyone agrees that in Chinese landscape paintings, the most important cultural bond is to ancient Chinese Taoism, and to a lesser degree, to Confucianism. Obviously, then, the…

  4. Detecting Corrosion Under Paint and Insulation

    NASA Technical Reports Server (NTRS)

    Bastin, Gary L.

    2011-01-01

    Corrosion is a major concern at the Kennedy Space Center in Florida due to the proximity of the center to the Atlantic Ocean and to salt water lagoons. High humidity, salt fogs, and ocean breezes, provide an ideal environment in which painted steel structures become corroded. Maintenance of painted steel structures is a never-ending process.

  5. 29 CFR 1915.35 - Painting.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... areas within or around the vessel or dry dock. (5) All motors and control equipment shall be of the... materials. All motors and associated control equipment shall be properly maintained and grounded. (6) Only non-sparking paint buckets, spray guns and tools shall be used. Metal parts of paint brushes...

  6. 29 CFR 1915.35 - Painting.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... areas within or around the vessel or dry dock. (5) All motors and control equipment shall be of the... materials. All motors and associated control equipment shall be properly maintained and grounded. (6) Only non-sparking paint buckets, spray guns and tools shall be used. Metal parts of paint brushes...

  7. Order-fractal transitions in abstract paintings

    NASA Astrophysics Data System (ADS)

    de la Calleja, E. M.; Cervantes, F.; de la Calleja, J.

    2016-08-01

    In this study, we determined the degree of order for 22 Jackson Pollock paintings using the Hausdorff-Besicovitch fractal dimension. Based on the maximum value of each multi-fractal spectrum, the artworks were classified according to the year in which they were painted. It has been reported that Pollock's paintings are fractal and that this feature was more evident in his later works. However, our results show that the fractal dimension of these paintings ranges among values close to two. We characterize this behavior as a fractal-order transition. Based on the study of disorder-order transition in physical systems, we interpreted the fractal-order transition via the dark paint strokes in Pollock's paintings as structured lines that follow a power law measured by the fractal dimension. We determined self-similarity in specific paintings, thereby demonstrating an important dependence on the scale of observations. We also characterized the fractal spectrum for the painting entitled Teri's Find. We obtained similar spectra for Teri's Find and Number 5, thereby suggesting that the fractal dimension cannot be rejected completely as a quantitative parameter for authenticating these artworks.

  8. Roosters Rule: A Painted Paper Collage

    ERIC Educational Resources Information Center

    Brady, Susan

    2011-01-01

    On perusing American collage artist Eric Carle's book, "Rooster's Off to See the World," at an annual school book fair, the author, mesmerized by the carnival of colors and collage on each page, thought "What a wonderful visual aid for a combination painting and collage unit." Her first-graders were involved in a painting unit, and knowing their…

  9. Electrically Conductive White Thermal-Control Paint

    NASA Technical Reports Server (NTRS)

    Hsieh, Cheng-Hsien; Forsberg, Gustaf A.; O'Donnell, Timothy P.

    1995-01-01

    Report describes development of white thermal-control paint intended for use on spacecraft. Paint required to exhibit combination of high emittance (equal to or greater than 0.90), low absorptance (equal to or less than 0.20), and electrical conductivity sufficient to prevent charging with static electricity to potentials beyond range of plus or minus 10 V.

  10. Structural Color Painting by Rubbing Particle Powder

    NASA Astrophysics Data System (ADS)

    Park, Choojin; Koh, Kunsuk; Jeong, Unyong

    2015-02-01

    Structural colors originate from purely physical structures. Scientists have been inspired to mimic the structures found in nature, the realization of these structures still presents a great challenge. We have recently introduced unidirectional rubbing of a dry particle powder on a rubbery surface as a quick, highly reproducible means to fabricate a single crystal monolayer assembly of particles over an unlimited area. This study extends the particle-rubbing process to a novel fine-art painting, structural color painting (SCP). SCP is based on structural coloring with varying iridescence according to the crystal orientation, as controlled by the rubbing direction. This painting technique can be applied on curved surfaces, which enriches the objects to be painted and helps the painter mimic the structures found in nature. It also allows for quick fabrication of complicated particle-assembly patterns, which enables replication of paintings.

  11. Structural Color Painting by Rubbing Particle Powder

    PubMed Central

    Park, ChooJin; Koh, Kunsuk; Jeong, Unyong

    2015-01-01

    Structural colors originate from purely physical structures. Scientists have been inspired to mimic the structures found in nature, the realization of these structures still presents a great challenge. We have recently introduced unidirectional rubbing of a dry particle powder on a rubbery surface as a quick, highly reproducible means to fabricate a single crystal monolayer assembly of particles over an unlimited area. This study extends the particle-rubbing process to a novel fine-art painting, structural color painting (SCP). SCP is based on structural coloring with varying iridescence according to the crystal orientation, as controlled by the rubbing direction. This painting technique can be applied on curved surfaces, which enriches the objects to be painted and helps the painter mimic the structures found in nature. It also allows for quick fabrication of complicated particle-assembly patterns, which enables replication of paintings. PMID:25661669

  12. Emissions of odorous aldehydes from alkyd paint

    NASA Astrophysics Data System (ADS)

    Chang, John C. S.; Guo, Zhishi

    Aldehyde emissions are widely held responsible for the acrid after-odor of drying alkyd-based paint films. The aldehyde emissions from three different alkyd paints were measured in small environ-mental chambers. It was found that, for each gram of alkyd paint applied, more than 2 mg of aldehydes (mainly hexanal) were emitted during the curing (drying) period. Since no measurable hexanal was found in the original paint, it is suspected that the aldehydes emitted were produced by autoxidation of the unsaturated fatty acid esters in the alkyd resins. The hexanal emission rate was simulated by a model assuming that the autoxidation process was controlled by a consecutive first-order reaction mechanism. Using the emission rate model, indoor air quality simulation indicated that the hexanal emissions can result in prolonged (several days) exposure risk to occupants. The occupant exposure to aldehydes emitted from alkyd paint also could cause sensory irritation and other health concerns.

  13. Subsurface Raman analysis of thin painted layers.

    PubMed

    Conti, Claudia; Colombo, Chiara; Realini, Marco; Zerbi, Giuseppe; Matousek, Pavel

    2014-01-01

    Here we present, for the first time, an extension of spatially offset Raman spectroscopy to thin (tens of micrometers thick), highly turbid stratified media such as those encountered in paintings. The method permits the non-destructive interrogation of painted layers in situations where conventional Raman microscopy is not applicable due to high turbidity of the top layer(s). The concept is demonstrated by recovering the pure Raman spectra of paint sub-layers that are completely obscured by paint over-layers. Potential application areas include the analysis of paintings in art preservation and restoration avoiding the cross-sectional analysis used currently with this type of samples. The technique also holds promise for the development as a non-destructive subsurface tool for in situ analysis using portable instruments.

  14. Paint removal activities in the US Navy

    NASA Astrophysics Data System (ADS)

    Kozol, Joseph

    1993-03-01

    Use of methylene chloride and phenol based chemical strippers for aircraft paint removal generates large quantities of hazardous waste and creates health and safety problems for operating personnel. This paper presents an overview of the U.S. Navy's activities in the investigation and implementation of alternate paint stripping methods which will minimize or eliminate hazardous waste and provide a safe operating environment. Alternate paint removal methods under investigation by the Navy at the present time include use of non-hazardous chemical paint removers, xenon flashlamp/CO2 pellets, lasers and plastic media. Plastic media blasting represents a mature technology in current usage for aircraft paint stripping and is being investigated for determination of its effects on Navy composite aircraft configurations.

  15. Fragmentation of drying paint layers

    NASA Astrophysics Data System (ADS)

    Bakos, Katinka; Dombi, András; Járai-Szabó, Ferenc; Néda, Zoltán

    2013-11-01

    Fragmentation of thin layers of drying granular materials on a frictional surface are studied both by experiments and computer simulations. Besides a qualitative description of the fragmentation phenomenon, the dependence of the average fragment size as a function of the layer thickness is thoroughly investigated. Experiments are done using a special nail polish, which forms characteristic crack structures during drying. In order to control the layer thickness, we diluted the nail polish in acetone and evaporated in a controlled manner different volumes of this solution on glass surfaces. During the evaporation process we managed to get an instable paint layer, which formed cracks as it dried out. In order to understand the obtained structures a previously developed spring-block model was implemented in a three-dimensional version. The experimental and simulation results proved to be in excellent qualitative and quantitative agreement. An earlier suggested scaling relation between the average fragment size and the layer thickness is reconfirmed.

  16. Accuracy of Pressure Sensitive Paint

    NASA Technical Reports Server (NTRS)

    Liu, Tianshu; Guille, M.; Sullivan, J. P.

    2001-01-01

    Uncertainty in pressure sensitive paint (PSP) measurement is investigated from a standpoint of system modeling. A functional relation between the imaging system output and luminescent emission from PSP is obtained based on studies of radiative energy transports in PSP and photodetector response to luminescence. This relation provides insights into physical origins of various elemental error sources and allows estimate of the total PSP measurement uncertainty contributed by the elemental errors. The elemental errors and their sensitivity coefficients in the error propagation equation are evaluated. Useful formulas are given for the minimum pressure uncertainty that PSP can possibly achieve and the upper bounds of the elemental errors to meet required pressure accuracy. An instructive example of a Joukowsky airfoil in subsonic flows is given to illustrate uncertainty estimates in PSP measurements.

  17. The public health relevance of air pollution abatement.

    PubMed

    Künzli, N

    2002-07-01

    Assuming a causal relationship between current levels of air pollution and morbidity/mortality, it is crucial to estimate the public health relevance of the problem. The derivation of air pollution attributable cases faces inherent uncertainties and requires influential assumptions. Based on the results of the trinational impact assessment study of Austria, France, and Switzerland, where prudent estimates of the air pollution attributable cases (mortality, chronic bronchitis incidence, hospital admissions, acute bronchitis among children, restricted activity days, asthma attacks) have been made, influential uncertainties are quantified in this review. The public health impact of smoking, environmental tobacco smoke, and air pollution on the prevalence of chronic cough/phlegm are outlined. Despite all methodological caveats, impact assessment studies clearly suggest that public health largely benefits from better air quality. The studies are selective underestimates as they are strongly driven by mortality, but do not include full quantification of the impact on morbidity and their consequences on quality of life among the diseased and the caregivers. Air pollution abatement strategies are usually political in nature, targeting at polities, regulation and technology in mobile or stationary sources rather than at individuals. It is of note that key clean air strategies converge into abatement of climate change. In general, energy consumption is very closely related to both air pollution and greenhouse gases. The dominant causes of both problems are the excessive and inefficient combustion of fossil fuel. Thus, for many policy options, the benefit of air pollution abatement will go far beyond what prudent health-impact assessments may derive. From a climate change and air pollution perspective, improved energy efficiency and a strong and decisive departure from the "fossil fuel" combustion society is a science-based must. Health professionals must raise their voices

  18. Inadvertent polychlorinated biphenyls in commercial paint pigments.

    PubMed

    Hu, Dingfei; Hornbuckle, Keri C

    2010-04-15

    A polychlorinated biphenyl (PCB) that was not produced as part of the Aroclor mixtures banned in the 1980s was recently reported in air samples collected in Chicago, Philadelphia, the Arctic, and several sites around the Great Lakes. In Chicago, the congener 3,3'-dichlorobiphenyl or PCB11 was found to be the fifth most concentrated congener and ubiquitous throughout the city. The congener exhibited strong seasonal concentration trends that suggest volatilization of this compound from common outdoor surfaces. Due to these findings and also the compound's presence in waters that received waste from paint manufacturing facilities, we hypothesized that PCB11 may be present in current commercial paint. In this study we measured PCBs in paint sold on the current retail market. We tested 33 commercial paint pigments purchased from three local paint stores. The pigment samples were analyzed for all 209 PCB congeners using gas chromatography with tandem mass spectrometry (GC-MS/MS). More than 50 PCB congeners including several dioxin-like PCBs were detected, and the PCB profiles varied due to different types of pigments and different manufacturing processes. PCB congeners were detected in azo and phthalocyanine pigments which are commonly used in paint but also in inks, textiles, paper, cosmetics, leather, plastics, food and other materials. Our findings suggest several possible mechanisms for the inadvertent production of specific PCB congeners during the manufacturing of paint pigments.

  19. Inadvertent Polychlorinated Biphenyls in Commercial Paint Pigments†

    PubMed Central

    2009-01-01

    A polychlorinated biphenyl (PCB) that was not produced as part of the Aroclor mixtures banned in the 1980s was recently reported in air samples collected in Chicago, Philadelphia, the Arctic, and several sites around the Great Lakes. In Chicago, the congener 3,3′-dichlorobiphenyl or PCB11 was found to be the fifth most concentrated congener and ubiquitous throughout the city. The congener exhibited strong seasonal concentration trends that suggest volatilization of this compound from common outdoor surfaces. Due to these findings and also the compound’s presence in waters that received waste from paint manufacturing facilities, we hypothesized that PCB11 may be present in current commercial paint. In this study we measured PCBs in paint sold on the current retail market. We tested 33 commercial paint pigments purchased from three local paint stores. The pigment samples were analyzed for all 209 PCB congeners using gas chromatography with tandem mass spectrometry (GC-MS/MS). More than 50 PCB congeners including several dioxin-like PCBs were detected, and the PCB profiles varied due to different types of pigments and different manufacturing processes. PCB congeners were detected in azo and phthalocyanine pigments which are commonly used in paint but also in inks, textiles, paper, cosmetics, leather, plastics, food and other materials. Our findings suggest several possible mechanisms for the inadvertent production of specific PCB congeners during the manufacturing of paint pigments. PMID:19957996

  20. Waste abatement: recycling, disposal practices can cut costs.

    PubMed

    Paul, A; Strout, P

    1997-09-01

    On average, most healthcare facilities are doing less than they should in the areas of source reduction and recycling, and will likely do so until mandated by law. The main reasons for this are ever-tightening healthcare budgets, limited staffing, and the cost of operating recycling programs compared to the cost of general solid waste disposal. Poor record keeping also may also be hampering the final decision to recycle. This article, Part II on waste abatement practices in healthcare organizations, examines what factors facilities should consider in establishing a recycling program, and analyzes cost-effective collection and disposal practices.

  1. Alkali Silicate Vehicle Forms Durable, Fireproof Paint

    NASA Technical Reports Server (NTRS)

    Schutt, John B.; Seindenberg, Benjamin

    1964-01-01

    The problem: To develop a paint for use on satellites or space vehicles that exhibits high resistance to cracking, peeling, or flaking when subjected to a wide range of temperatures. Organic coatings will partially meet the required specifications but have the inherent disadvantage of combustibility. Alkali-silicate binders, used in some industrial coatings and adhesives, show evidence of forming a fireproof paint, but the problem of high surface-tension, a characteristic of alkali silicates, has not been resolved. The solution: Use of a suitable non-ionic wetting agent combined with a paint incorporating alkali silicate as the binder.

  2. New black paint for cryogenic infrared applications

    NASA Technical Reports Server (NTRS)

    Houck, J. R.

    1983-01-01

    A black paint has been developed and tested for cryogenic applications involving wavelengths beyond 10 microns. The paint has been used extensively for liquid helium cooled applications in a variety of instruments operating between 10 and 120 microns. The material is applied by brush over a spray or brush applied primer coat. A final covering is applied by either brush or spray. The composition and preparation of the paint are described, as are data about its outgassing properties. Infrared reflection and scattering data obtained by other groups which compare this material to other commercially available surface preparations are presented.

  3. Incite Their Interest with a Collaborative Painting Project

    ERIC Educational Resources Information Center

    Woodcock, Jo

    2011-01-01

    This article describes a collaborative painting project that allows first- through third-grade students to work with partners to create a four-inch square of a group painting and learn the basics of mixing paints to produce lights and darks, and tints and shades. One by one, the students worked on the painting in their free time. The author kept a…

  4. [Study of Paints and Drawing Techniques of Fine Brushwork Yunlong Ripples Painting in Qing Dynasty].

    PubMed

    Hao, Sheng-cai; Shi, Ji-long; Wang, Ji-gang; He, Qiu-ju; Qi, Xiao-kun; Zhou, Zhong; Zhou, Wen-hua

    2016-02-01

    In order to study the paints and techniques of decorative patterns of dragon among clouds and water waves, the materials based on a Qing Dynasty meticulous painting were measured by three-dimensional video microscopy, Raman microscopy and energy dispersive X-ray fluorescence spectroscopy. The results showed that the green clothes was firstly colored by Paris green, the decorative patterns of dragon among clouds and water waves were then painted by hematite, the edge was delineated by brass powder at last. The dark yellow area within the decorative patterns was presented due to the interaction of green and red paints. In addition, ultramarine blue was checked in the painting. According to the first synthesized time of ultramarine blue and Paris green, we can make sure the time limit of the painting finished. PMID:27209755

  5. [Study of Paints and Drawing Techniques of Fine Brushwork Yunlong Ripples Painting in Qing Dynasty].

    PubMed

    Hao, Sheng-cai; Shi, Ji-long; Wang, Ji-gang; He, Qiu-ju; Qi, Xiao-kun; Zhou, Zhong; Zhou, Wen-hua

    2016-02-01

    In order to study the paints and techniques of decorative patterns of dragon among clouds and water waves, the materials based on a Qing Dynasty meticulous painting were measured by three-dimensional video microscopy, Raman microscopy and energy dispersive X-ray fluorescence spectroscopy. The results showed that the green clothes was firstly colored by Paris green, the decorative patterns of dragon among clouds and water waves were then painted by hematite, the edge was delineated by brass powder at last. The dark yellow area within the decorative patterns was presented due to the interaction of green and red paints. In addition, ultramarine blue was checked in the painting. According to the first synthesized time of ultramarine blue and Paris green, we can make sure the time limit of the painting finished.

  6. Color alteration of the paint used for iris painting in ocular prostheses.

    PubMed

    Fernandes, Aline Ursula Rocha; Goiato, Marcelo Coelho; Batista, Marcos Antônio Jacó; Santos, Daniela Micheline Dos

    2009-01-01

    The purpose of this study was to assess color alteration of the paints used for iris painting in artificial eyes. Five disks of heat cured acrylic resin were confectioned by microwave energy for each paint analyzed, in a total of 40 specimens. Each specimen consisted of a colorless acrylic resin disk and another of equal size, of scleral white colored acrylic resin, with the painting interposed between the two disks. The specimens were submitted to an accelerated aging process in a chamber under ultraviolet radiation for 1,008 hours. To assess color variation, a reflective spectrophotometer was used. The results were statistically analyzed by ANOVA and the Tukey test (p < 0.05). All the paints underwent chromatic alteration. The oil paint presented the highest resistance to accelerated aging. PMID:20027445

  7. Paint for detection of radiological or chemical agents

    DOEpatents

    Farmer, Joseph C.; Brunk, James L.; Day, Sumner Daniel

    2010-08-24

    A paint that warns of radiological or chemical substances comprising a paint operatively connected to the surface, an indicator material carried by the paint that provides an indication of the radiological or chemical substances, and a thermo-activation material carried by the paint. In one embodiment, a method of warning of radiological or chemical substances comprising the steps of painting a surface with an indicator material, and monitoring the surface for indications of the radiological or chemical substances. In another embodiment, a paint is operatively connected to a vehicle and an indicator material is carried by the paint that provides an indication of the radiological or chemical substances.

  8. RIGGERS LOFT/PAINT SHOP/SHEET METAL SHOP, VIEW TO SOUTHEAST. THE PAINT ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    RIGGERS LOFT/PAINT SHOP/SHEET METAL SHOP, VIEW TO SOUTHEAST. THE PAINT SHOP WAS LOCATED IN THE CLOSEST CORNER OF THE BUILDING. THE SHEET METAL SHOP WAS LOCATED IN THE CORNER OF THE BUILDING ON THE RIGHT. THE RIGGERS LOFT WAS LOCATED IN THE PORTION OF THE BUILDING OUT OF VIEW TO THE LEFT - Rosie the Riveter National Historical Park, Riggers Loft/Paint Shop/Sheet Metal Shop, 1322 Canal Boulevard, Richmond, Contra Costa County, CA

  9. Cost of abating greenhouse gas emissions with cellulosic ethanol.

    PubMed

    Dwivedi, Puneet; Wang, Weiwei; Hudiburg, Tara; Jaiswal, Deepak; Parton, William; Long, Stephen; DeLucia, Evan; Khanna, Madhu

    2015-02-17

    We develop an integrated framework to determine and compare greenhouse gas (GHG) intensities and production costs of cellulosic ethanol derived from corn stover, switchgrass, and miscanthus grown on high and low quality soils for three representative counties in the Eastern United States. This information is critical for assessing the cost-effectiveness of utilizing cellulosic ethanol for mitigating GHG emissions and designing appropriate policy incentives to support cellulosic ethanol production nationwide. We find considerable variations in the GHG intensities and production costs of ethanol across feedstocks and locations mostly due to differences in yields and soil characteristics. As compared to gasoline, the GHG savings from miscanthus-based ethanol ranged between 130% and 156% whereas that from switchgrass ranged between 97% and 135%. The corresponding range for GHG savings with corn stover was 57% to 95% and marginally below the threshold of at least 60% for biofuels classified as cellulosic biofuels under the Renewable Fuels Standard. Estimates of the costs of producing ethanol relative to gasoline imply an abatement cost of at least $48 Mg(-1) of GHG emissions (carbon dioxide equivalent) abated and can be used to infer the minimum carbon tax rate needed to induce consumption of cellulosic ethanol. PMID:25588032

  10. Cost of abating greenhouse gas emissions with cellulosic ethanol.

    PubMed

    Dwivedi, Puneet; Wang, Weiwei; Hudiburg, Tara; Jaiswal, Deepak; Parton, William; Long, Stephen; DeLucia, Evan; Khanna, Madhu

    2015-02-17

    We develop an integrated framework to determine and compare greenhouse gas (GHG) intensities and production costs of cellulosic ethanol derived from corn stover, switchgrass, and miscanthus grown on high and low quality soils for three representative counties in the Eastern United States. This information is critical for assessing the cost-effectiveness of utilizing cellulosic ethanol for mitigating GHG emissions and designing appropriate policy incentives to support cellulosic ethanol production nationwide. We find considerable variations in the GHG intensities and production costs of ethanol across feedstocks and locations mostly due to differences in yields and soil characteristics. As compared to gasoline, the GHG savings from miscanthus-based ethanol ranged between 130% and 156% whereas that from switchgrass ranged between 97% and 135%. The corresponding range for GHG savings with corn stover was 57% to 95% and marginally below the threshold of at least 60% for biofuels classified as cellulosic biofuels under the Renewable Fuels Standard. Estimates of the costs of producing ethanol relative to gasoline imply an abatement cost of at least $48 Mg(-1) of GHG emissions (carbon dioxide equivalent) abated and can be used to infer the minimum carbon tax rate needed to induce consumption of cellulosic ethanol.

  11. Standard Operating Procedure for the Preparation of Lead-Containing Paint Films and Lead-in-Paint Diagnostic Test Materials

    EPA Science Inventory

    This SOP describes the preparation of stand-alone, lead paint films, prepared according to the old paint recipes. Further, this SOP describes the use of these paint films for the preparation of simulated old paints on a variety of substrates. Substrates used included wood, stee...

  12. Pointillist Watercolor Paintings: Exploring Optical Mixing.

    ERIC Educational Resources Information Center

    Hamwi, Richard

    2001-01-01

    Focuses on the pointillist painting process offering background information about technique and how it can be used in the art classroom. Explores the appropriateness of the process for elementary through secondary school students. Includes educational objectives. (CMK)

  13. Paint spray tests for respirators: aerosol characteristics.

    PubMed

    Ackley, M W

    1980-05-01

    Liquid paint is sprayed from an atomizing nozzle to form an aerosol for testing paint spray respirators. The generated aerosol conditions are dependent upon liguid properties, spray-nozzle flow conditions and droplet evaporation. A technique was developed for controlling the aerosol concentrations reliably. Particle-size distributions of lacquer and enamel have been measured. The lacquer distribution was found to be multi-modal. Aerosol concentration dradients arise when the nozzle is not properly positioned. Filter loading resistance is significantly affected by these concentration variations. With regard to selection of standard aerosol test be improved by modifying the current NIOSH criteria to include a description of the particle-size distribution, a more precise definition of the paint and paint thinner chemical compositions, and a narrower concentration range. PMID:6932174

  14. Darkness and depth in early Renaissance painting

    NASA Astrophysics Data System (ADS)

    Tyler, Christopher

    2010-02-01

    Contrast has always been appreciated as a significant factor in image quality, but it is less widely recognized that it is a key factor in the representation of depth, solidity and three-dimensionality in images in general, and in paintings in particular. This aspect of contrast was a key factor in the introduction of oil paint as a painting medium at the beginning of the fifteenth century, as a practical means of contrast enhancement. However, recent conservatorship efforts have established that the first oil paintings were not, as commonly supposed, by van Eyck in Flanders in the 1430s, but by Masolino da Panicale in Italy in the 1420s. These developments led to the use of chiaroscuro technique in various forms, all of which are techniques for enhanced shadowing.

  15. Optical coherence tomography for painting diagnostics

    NASA Astrophysics Data System (ADS)

    Arecchi, T.; Bellini, M.; Corsi, C.; Fontana, R.; Materazzi, M.; Pezzati, L.; Tortora, A.

    2005-06-01

    In the last few years many non-destructive techniques have entered the field of painting conservation, and most of them are routinely applied to study and monitoring the painting status. Among them optical techniques are by now widely diffused and extremely well received because of their effectiveness and safety, nevertheless none of them is suitable for a quantitative characterization of varnish. One of the most important and often controversial stages of painting restoration is the surface cleaning process up to now being carried out without any tool to measure the actual varnish thickness but microscope observation of micro-detach. In this work we present an application of Optical Coherence Tomography to non-destructive diagnostics of artwork: the potentiality of this technique is demonstrated by measuring the thickness of the varnish layer in a fragment of a nineteenth-century oil painting.

  16. Arthritis in Flemish paintings (1400-1700).

    PubMed Central

    Dequeker, J

    1977-01-01

    A close examination of the hands of people depicted in paintings of the Flemish school showed that in five paintings there were figures with hand lesions resembling those of rhematoid arthritis. Although none of the deformities or swellings are indisputable examples of rheumatoid arthritis, they do at least suggest that the painters must have been confronted with rheumatoid-like lesions in their models. In two other paintings there were signs of rheumatic fever and of temporal arteritis. No arthritic lesions were found in the works of painters of the Italian Renaissance, probably because they are less detailed. The finding of rheumatoid deformities in the Flemish paintings does, however, question the general belief that rheumatoid arthritis is a condition that has arisen relatively recently. Images FIGS 1-2 FIG 3 FIG 4 FIG 5 FIG 6 FIG 7 PMID:324568

  17. Terahertz imaging for non-destructive evaluation of mural paintings

    NASA Astrophysics Data System (ADS)

    Jackson, J. B.; Mourou, M.; Whitaker, J. F.; Duling, I. N.; Williamson, S. L.; Menu, M.; Mourou, G. A.

    2008-02-01

    The feasibility of applying time-domain, terahertz spectroscopic imaging to the evaluation of underdrawings and paint layers embedded within wall paintings is demonstrated. Metallic and dielectric paint patterns and a graphite drawing are resolved through both paint and plaster overlayers using a pulsed-terahertz reflectometer and imaging system. We calculated the bulk refractive indices of four common pigments and used them to confirm color domains in a terahertz-beam spectral image of a painting.

  18. 26 CFR 53.4961-1 - Abatement of second tier taxes for correction within correction period.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 26 Internal Revenue 17 2013-04-01 2013-04-01 false Abatement of second tier taxes for correction... TAXES Second Tier Excise Taxes § 53.4961-1 Abatement of second tier taxes for correction within... second tier tax imposed with respect to the event shall not be assessed. If the tax has been assessed,...

  19. 26 CFR 53.4961-1 - Abatement of second tier taxes for correction within correction period.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 26 Internal Revenue 17 2012-04-01 2012-04-01 false Abatement of second tier taxes for correction... TAXES Second Tier Excise Taxes § 53.4961-1 Abatement of second tier taxes for correction within... second tier tax imposed with respect to the event shall not be assessed. If the tax has been assessed,...

  20. 26 CFR 53.4961-1 - Abatement of second tier taxes for correction within correction period.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 26 Internal Revenue 17 2014-04-01 2014-04-01 false Abatement of second tier taxes for correction... TAXES Second Tier Excise Taxes § 53.4961-1 Abatement of second tier taxes for correction within... second tier tax imposed with respect to the event shall not be assessed. If the tax has been assessed,...

  1. 26 CFR 53.4961-1 - Abatement of second tier taxes for correction within correction period.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 17 2010-04-01 2010-04-01 false Abatement of second tier taxes for correction... TAXES Second Tier Excise Taxes § 53.4961-1 Abatement of second tier taxes for correction within... second tier tax imposed with respect to the event shall not be assessed. If the tax has been assessed,...

  2. 26 CFR 53.4961-1 - Abatement of second tier taxes for correction within correction period.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 26 Internal Revenue 17 2011-04-01 2011-04-01 false Abatement of second tier taxes for correction... TAXES Second Tier Excise Taxes § 53.4961-1 Abatement of second tier taxes for correction within... second tier tax imposed with respect to the event shall not be assessed. If the tax has been assessed,...

  3. 29 CFR 4208.9 - Plan adoption of additional abatement conditions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 29 Labor 9 2014-07-01 2014-07-01 false Plan adoption of additional abatement conditions. 4208.9... Plan adoption of additional abatement conditions. (a) General rule. A plan may by amendment, subject to... actuarial valuation report of the plan. (5) A statement certifying that notice of the adoption of...

  4. 29 CFR 4208.9 - Plan adoption of additional abatement conditions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 9 2010-07-01 2010-07-01 false Plan adoption of additional abatement conditions. 4208.9... Plan adoption of additional abatement conditions. (a) General rule. A plan may by amendment, subject to... actuarial valuation report of the plan. (5) A statement certifying that notice of the adoption of...

  5. 29 CFR 4208.9 - Plan adoption of additional abatement conditions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 29 Labor 9 2012-07-01 2012-07-01 false Plan adoption of additional abatement conditions. 4208.9... Plan adoption of additional abatement conditions. (a) General rule. A plan may by amendment, subject to... actuarial valuation report of the plan. (5) A statement certifying that notice of the adoption of...

  6. 29 CFR 4208.9 - Plan adoption of additional abatement conditions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 29 Labor 9 2011-07-01 2011-07-01 false Plan adoption of additional abatement conditions. 4208.9... Plan adoption of additional abatement conditions. (a) General rule. A plan may by amendment, subject to... actuarial valuation report of the plan. (5) A statement certifying that notice of the adoption of...

  7. 29 CFR 4208.9 - Plan adoption of additional abatement conditions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 29 Labor 9 2013-07-01 2013-07-01 false Plan adoption of additional abatement conditions. 4208.9... Plan adoption of additional abatement conditions. (a) General rule. A plan may by amendment, subject to... actuarial valuation report of the plan. (5) A statement certifying that notice of the adoption of...

  8. 41 CFR 102-80.20 - What are Federal agencies' responsibilities concerning the abatement of radon?

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... agencies' responsibilities concerning the abatement of radon? 102-80.20 Section 102-80.20 Public Contracts... REGULATION REAL PROPERTY 80-SAFETY AND ENVIRONMENTAL MANAGEMENT Safety and Environmental Management Radon § 102-80.20 What are Federal agencies' responsibilities concerning the abatement of radon?...

  9. 41 CFR 102-80.20 - What are Federal agencies' responsibilities concerning the abatement of radon?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... agencies' responsibilities concerning the abatement of radon? 102-80.20 Section 102-80.20 Public Contracts... REGULATION REAL PROPERTY 80-SAFETY AND ENVIRONMENTAL MANAGEMENT Safety and Environmental Management Radon § 102-80.20 What are Federal agencies' responsibilities concerning the abatement of radon?...

  10. 41 CFR 102-80.20 - What are Federal agencies' responsibilities concerning the abatement of radon?

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... agencies' responsibilities concerning the abatement of radon? 102-80.20 Section 102-80.20 Public Contracts... REGULATION REAL PROPERTY 80-SAFETY AND ENVIRONMENTAL MANAGEMENT Safety and Environmental Management Radon § 102-80.20 What are Federal agencies' responsibilities concerning the abatement of radon?...

  11. 41 CFR 102-80.20 - What are Federal agencies' responsibilities concerning the abatement of radon?

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... agencies' responsibilities concerning the abatement of radon? 102-80.20 Section 102-80.20 Public Contracts... REGULATION REAL PROPERTY 80-SAFETY AND ENVIRONMENTAL MANAGEMENT Safety and Environmental Management Radon § 102-80.20 What are Federal agencies' responsibilities concerning the abatement of radon?...

  12. 41 CFR 102-80.20 - What are Federal agencies' responsibilities concerning the abatement of radon?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... agencies' responsibilities concerning the abatement of radon? 102-80.20 Section 102-80.20 Public Contracts... REGULATION REAL PROPERTY 80-SAFETY AND ENVIRONMENTAL MANAGEMENT Safety and Environmental Management Radon § 102-80.20 What are Federal agencies' responsibilities concerning the abatement of radon?...

  13. Asbestos concentrations two years after abatement in seventeen schools. Final summary report

    SciTech Connect

    Kominsky, J.R.; Freyberg, R.W.; Brownlee, J.A.; Gerber, D.R.

    1992-03-01

    Airborne asbestos concentrations were measured at 17 schools that underwent an asbestos abatement 2 years before in 1988. These 17 schools, which involved 20 abatement sites, were part of a study conducted by the U.S. Environmental Protection Agency (EPA) and the New Jersey Department of Health (NJDOH) in 1988. The 1988 study showed that asbestos concentrations measured independently by the NJDOH and EPA during the clearance phase of the abatement were elevated in the abatement and perimeter areas compared with outdoor concentrations. The present study was conducted to determine the current levels of airborne asbestos under simulated occupancy conditions and to determine whether the elevated levels found during the clearance phase were still present 2 years after abatement. In 1990, four sites showed significantly higher mean asbestos concentrations inside the building (i.e., the previously abated area and/or perimeter area) compared with those outdoors (p<0.05). In 1990, the mean asbestos concentration measured in the perimeter area at one site and in the previously abated area at two sites were significantly higher than those in 1988 (p<0.05). Variations in asbestos levels between 1988 and 1990 may be due to sampling techniques (passive and aggressive versus modified aggressive), residual air-entrainable asbestos from the 1988 abatement, or air-entrainable asbestos from operations and maintenance activities since 1988.

  14. 30 CFR 75.401 - Abatement of dust; water or water with a wetting agent.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Abatement of dust; water or water with a wetting agent. 75.401 Section 75.401 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Combustible Materials and Rock Dusting § 75.401 Abatement...

  15. 30 CFR 75.401 - Abatement of dust; water or water with a wetting agent.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Abatement of dust; water or water with a wetting agent. 75.401 Section 75.401 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT... Materials and Rock Dusting § 75.401 Abatement of dust; water or water with a wetting agent....

  16. 30 CFR 75.401 - Abatement of dust; water or water with a wetting agent.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Abatement of dust; water or water with a wetting agent. 75.401 Section 75.401 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT... Materials and Rock Dusting § 75.401 Abatement of dust; water or water with a wetting agent....

  17. Effects Of Moisture On Zinc Orthotitanate Paint

    NASA Technical Reports Server (NTRS)

    Mon, Gordon R.; Gonzalez, Charles C.; Ross, JR., Ronald g.; Wen, Liang C.; O'Donnell, Timothy

    1991-01-01

    Report presents results of tests of electrical conductivity and resistance to corrosion of zinc orthotitanate (ZOT) paint. Measured effects of temperature, humidity, and vacuum on ceramic paint. Used as temperature-control coating designed to have low and stable ratio of absorptance to emittance for heat radiation. Helps to prevent buildup of static electric charge and helps to protect electronic circuitry from potentially damaging static discharges.

  18. Painting a Data-Rich Picture

    ERIC Educational Resources Information Center

    Earl, Lorna; Katz, Steven

    2005-01-01

    Using data for school reform is like painting a series of pictures--pictures that are subtle and capture the nuances of the subject. This is a far cry from drawing stick figures or paint-by-numbers. Imagine the experiences of the French painter Claude Monet as he wandered through his garden at Giverny at different times of the day and year,…

  19. A quantitative approach to painting styles

    NASA Astrophysics Data System (ADS)

    Vieira, Vilson; Fabbri, Renato; Sbrissa, David; da Fontoura Costa, Luciano; Travieso, Gonzalo

    2015-01-01

    This research extends a method previously applied to music and philosophy (Vilson Vieira et al., 2012), representing the evolution of art as a time-series where relations like dialectics are measured quantitatively. For that, a corpus of paintings of 12 well-known artists from baroque and modern art is analyzed. A set of 99 features is extracted and the features which most contributed to the classification of painters are selected. The projection space obtained provides the basis to the analysis of measurements. These quantitative measures underlie revealing observations about the evolution of painting styles, specially when compared with other humanity fields already analyzed: while music evolved along a master-apprentice tradition (high dialectics) and philosophy by opposition, painting presents another pattern: constant increasing skewness, low opposition between members of the same movement and opposition peaks in the transition between movements. Differences between baroque and modern movements are also observed in the projected "painting space": while baroque paintings are presented as an overlapped cluster, the modern paintings present minor overlapping and are disposed more widely in the projection than the baroque counterparts. This finding suggests that baroque painters shared aesthetics while modern painters tend to "break rules" and develop their own style.

  20. Automated Laser Paint Stripping (ALPS) update

    NASA Astrophysics Data System (ADS)

    Lovoi, Paul

    1993-03-01

    To date, the DoD has played a major role in funding a number of paint stripping programs. Some technologies have proven less effective than contemplated. Others are still in the validation phase. Paint stripping is one of the hottest issues being addressed by the finishing industry since the Environmental Protection Agency (EPA) has mandated that chemical stripping using methylene chloride/phenolic type strippers be stopped. The DoD and commercial aircraft companies are hard-pressed to find an alternative. Automated laser paint stripping has been identified as a technique for removing coatings from aircraft surfaces. International Technical Associates (InTA) was awarded a Navy contract for an automated laser paint stripping system (ALPS) that will remove paint from metallic and composite substrates. For the program, which will validate laser paint stripping, InTA will design, build, test, and install a system for fighter-sized aircraft at both the Norfolk and North Island (San Diego) Aviation Depots.

  1. Regional and sectoral marginal abatement cost curves for NOx incorporating controls, renewable electricity, energy efficiency and fuel switching

    EPA Science Inventory

    A marginal abatement cost curve (MACC) traces out the relationship between the quantity of pollution abated and the marginal cost of abating each additional unit. In the context of air quality management, MACCs typically are developed by sorting end-of-pipe controls by their resp...

  2. Design and Application of The Painting Material Supply System of The Painting Robot for Steel Products

    NASA Astrophysics Data System (ADS)

    Miyawaki, Kunio; Hisayasu, Azuma; Mori, Tsunehito; Miyazaki, Tatsuo; Nakashima, Yoshio

    With the increase of painting works and the decrease of skilled workers, the demand for robot painting of the large-scale steel product is rapidly increasing. But there are many technical problems in the development of the painting robot for this use. The collision between a robot and a work-piece is one of the most important problems, because the robot operates in a small space of a work-piece. Above all, the collision of the painting material supply hose with painted film on a work-piece is very serious. To avoid the hose collision, we propose an in-line type of paint supply mechanism using swivel joints. The key point in this system is the sealing performance and its durability, and we propose the piping system with compliance to strengthen the sealing performance. In this paper, the design method of this system is discussed on the basis of the analysis of the fluctuatinal elastic deformation of a O-ring in the swivel joint. We produced a prototype of the painting robot with the in-line system designed by this method. Application of this robot to the painting of ship-hull block is also discussed. Results from this application show the effectiveness of the in-line system.

  3. Best lighting for visual appreciation of artistic paintings--experiments with real paintings and real illumination.

    PubMed

    Nascimento, Sérgio Miguel Cardoso; Masuda, Osamu

    2014-04-01

    In a previous study based on monitor simulations of artistic paintings, it was found that the average correlated color temperature (CCT) of daylight preferred by a large set of observers to illuminate paintings was around 5100 K. The goal of the present study was to test if this result holds in real viewing conditions, i.e., with real paintings and real light sources. The same 11 paintings were tested in real conditions illuminated by a spectrally tunable light source and with accurate monitor simulations. To ensure uniform illumination across the paintings, only a central part of the paintings was visible to the observers. It was found that the average CCT preferred for real and monitor viewing conditions were very similar, 5500 and 5700 K, respectively. The somewhat larger CCT obtained with monitor viewing in relation to the former study was only observed in some paintings and was attributed to the smaller viewing area. These results confirm that CCT for best appreciation of paintings is higher than normally used in museums, and the viewing conditions, real or simulated, have only a minor effect.

  4. 78 FR 63148 - Approval and Promulgation of Implementation Plans; Tennessee; Bristol; 2010 Lead Base Year...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-23

    ... Base Year Emissions Inventory and Conversion of Conditional Approvals for Prevention of Significant... approve the Lead 2010 base year emissions inventory State Implementation Plan (SIP) revision submitted by... 2010 Lead Base Year Emissions Inventory IV. Conversion of Conditional Approvals for Tennessee's SIP...

  5. SMA Hybrid Composites for Dynamic Response Abatement Applications

    NASA Technical Reports Server (NTRS)

    Turner, Travis L.

    2000-01-01

    A recently developed constitutive model and a finite element formulation for predicting the thermomechanical response of Shape Memory Alloy (SMA) hybrid composite (SMAHC) structures is briefly described. Attention is focused on constrained recovery behavior in this study, but the constitutive formulation is also capable of modeling restrained or free recovery. Numerical results are shown for glass/epoxy panel specimens with embedded Nitinol actuators subjected to thermal and acoustic loads. Control of thermal buckling, random response, sonic fatigue, and transmission loss are demonstrated and compared to conventional approaches including addition of conventional composite layers and a constrained layer damping treatment. Embedded SMA actuators are shown to be significantly more effective in dynamic response abatement applications than the conventional approaches and are attractive for combination with other passive and/or active approaches.

  6. SO2 abatement, energy conservation, and productivity at copper cliff

    NASA Astrophysics Data System (ADS)

    Landolt, C. A.; Dutton, A.; Edwards, J. D.; McDonald, R. N.

    1992-09-01

    Inco pioneered the use of tonnage oxygen in nonferrous metallurgy when it commissioned the first industrial oxygen flash smelting process for the treatment of copper concentrates in the early 1950s. This was followed by other applications of oxygen such as the enrichment of reverberatory furnace and Peirce-Smith converter blasts; oxy-fuel smelting in reverb furnaces; and, very recently, flash conversion of chalcocite to copper. Inco is currently implementing a sulfur dioxide abatement project designed to reduce SO2 emissions from the smelter by 60 percent (to 265 kt) in 1994. At that time, oxygen consumption at the smelter will reach about 1.7 t O2/t Cu+Ni. Oxygen smelting and converting technology will lead toa substantial decrease in the use of fossil fuels and to the generation afhigh-strength SO2 off-gases suitable for cost-effective fixation in a new acid plant.

  7. Intermittent control procedures for the Geysers hydrogen sulfide emission abatement

    SciTech Connect

    Buick, B.D.; Mooney, M.L.

    1984-01-01

    Pacific Gas and Electric Company (PG and E) operates the world's largest geothermal steam electric power generation facility, currently about 1.140 megawatts (Mw). This facility is located about 80 miles north of San Francisco, California and is within a region referred to as the Known Geothermal Resource Area (KGRA). Pollutants resulting from this method of electric power generation are due to impurities in the geothermal steam. A major contaminate in the steam is hydrogen sulfide (H/sub 2/S), a regulated pollutant in California. The ambient air quality standard (AAQS) for this pollutant in California is 0.03 parts per million (ppM) averaged over one hour. H/sub 2/S is an invisible, unpleasant smelling gas present in varying concentrations in the geothermal steam. Its odor has been compared to the smell of rotten eggs. Since PG and E is increasingly relying on this source of electrical power generation, it has committed millions of dollars to the development, testing, acquisition, and installation of abatement equipment to reduce H/sub 2/S emissions during the past ten years. In order to reduce the number of exceeds of the AAQS during this developmental period, a predictive model was needed for interim abatement purposes. Most of the high hourly H/sub 2/S values occur with meteorological conditions having poor ventilation resulting from a combination of low wind speed and reduced mixing layer depths. This weather condition is most common during the months of June through October in California. A predictive model was developed from three years of hourly H/sub 2/S measurements of 0.03 ppM or greater in populated areas downwind of the generation facility and from observations of associated meteorological data.

  8. Abatement vs. treatment for efficient diffuse source water pollution management in terrestrial-marine systems.

    PubMed

    Roebeling, P C; Cunha, M C; Arroja, L; van Grieken, M E

    2015-01-01

    Marine ecosystems are affected by water pollution originating from coastal catchments. The delivery of water pollutants can be reduced through water pollution abatement as well as water pollution treatment. Hence, sustainable economic development of coastal regions requires balancing of the marginal costs from water pollution abatement and/or treatment and the associated marginal benefits from marine resource appreciation. Water pollution delivery reduction costs are, however, not equal across abatement and treatment options. In this paper, an optimal control approach is developed and applied to explore welfare maximizing rates of water pollution abatement and/or treatment for efficient diffuse source water pollution management in terrestrial-marine systems. For the case of diffuse source dissolved inorganic nitrogen water pollution in the Tully-Murray region, Queensland, Australia, (agricultural) water pollution abatement cost, (wetland) water pollution treatment cost and marine benefit functions are determined to explore welfare maximizing rates of water pollution abatement and/or treatment. Considering partial (wetland) treatment costs and positive water quality improvement benefits, results show that welfare gains can be obtained, primarily, through diffuse source water pollution abatement (improved agricultural management practices) and, to a minor extent, through diffuse source water pollution treatment (wetland restoration). PMID:26287831

  9. Contributions of Paint and Soil to Pb in Household Dust Wipes: An XAS Study

    NASA Astrophysics Data System (ADS)

    Pingitore, N. E.; Clague, J. W.; Amaya, M. A.

    2010-12-01

    Speciation of Pb by X-ray absorption spectroscopy (XAS) indicated that Pb compounds associated with lead-based paint accounted for perhaps half of the Pb in 24 household dust wipes collected in El Paso, Texas. Soil-derived, sorbed Pb, likely Pb-humate, was also a major Pb species in many of the dust wipes. Household dust wipes are a standard technique for evaluating health risks of Pb to children, particularly toddlers, in public and private housing. The level of Pb in the wipes does not, however, indicate whether the source of the Pb is the house itself (peeling or powdering interior or exterior paint) or external, from contaminated soil or airborne particulate matter brought into the house by wind or foot traction. Understanding the origin of Pb in household dust is important in remediation: cover the old paint or remove the yard soil. XAS speciation can assist in understanding the source of Pb in household dust. The presence of significant Pb-humate requires a soil source, and suggests the need for soil remediation. Such species of Pb as hydrocerussite, lead sulfate, lead silicate, and lead chromate can be presumed to be components of lead-based paint. These may represent interior and/or exterior paint and thus do not uniquely identify the locus of the Pb source(s). Pb L-III edge XAFS data were collected on beam lines 7-3, 10-2, and 11-2 at SSRL at typical conditions of 3 GeV field and 80-200 mA current, using Si(220) water- or liquid-nitrogen-cooled monochromator crystals. Data were collected at ambient temperature in fluorescence mode using a 13- or 30-element Ge detector with a Se 3 or 6 filter and Soller slits to reduce scattered radiation. This publication was made possible by grant numbers 1RO1-ES11367 and 1 S11 ES013339-01A1 from the National Institute of Environmental Health Sciences (NIEHS), NIH. Its contents are solely the responsibility of the authors and do not necessarily represent the official views of the NIEHS, NIH. Portions of this research were

  10. Comparative chromosome painting in Carnivora and Pholidota.

    PubMed

    Perelman, P L; Beklemisheva, V R; Yudkin, D V; Petrina, T N; Rozhnov, V V; Nie, W; Graphodatsky, A S

    2012-01-01

    The order of Carnivora has been very well characterized with over 50 species analyzed by chromosome painting and with painting probe sets made for 9 Carnivora species. Representatives of almost all families have been studied with few exceptions (Otariidae, Odobenidae, Nandiniidae, Prionodontidae). The patterns of chromosome evolution in Carnivora are discussed here. Overall, many Carnivora species retained karyotypes that only slightly differ from the ancestral carnivore karyotype. However, there are at least 3 families in which the ancestral carnivore karyotype has been severely rearranged - Canidae, Ursidae and Mephitidae. Here we report chromosome painting of yet another Carnivora species with a highly rearranged karyotype, Genetta pardina. Recurrent rearrangements make it difficult to define the ancestral chromosomal arrangement in several instances. Only 2 species of pangolins (Pholidota), a sister order of Carnivora, have been studied by chromosome painting. Future use of whole-genome sequencing data is discussed in the context of solving the questions that are beyond resolution of conventional banding techniques and chromosome painting. PMID:22889959

  11. Painting with polygons: a procedural watercolor engine.

    PubMed

    DiVerdi, Stephen; Krishnaswamy, Aravind; Měch, Radomír; Ito, Daichi

    2013-05-01

    Existing natural media painting simulations have produced high-quality results, but have required powerful compute hardware and have been limited to screen resolutions. Digital artists would like to be able to use watercolor-like painting tools, but at print resolutions and on lower end hardware such as laptops or even slates. We present a procedural algorithm for generating watercolor-like dynamic paint behaviors in a lightweight manner. Our goal is not to exactly duplicate watercolor painting, but to create a range of dynamic behaviors that allow users to achieve a similar style of process and result, while at the same time having a unique character of its own. Our stroke representation is vector based, allowing for rendering at arbitrary resolutions, and our procedural pigment advection algorithm is fast enough to support painting on slate devices. We demonstrate our technique in a commercially available slate application used by professional artists. Finally, we present a detailed analysis of the different vector-rendering technologies available.

  12. Training facilitates object recognition in cubist paintings.

    PubMed

    Wiesmann, Martin; Ishai, Alumit

    2010-01-01

    To the naïve observer, cubist paintings contain geometrical forms in which familiar objects are hardly recognizable, even in the presence of a meaningful title. We used fMRI to test whether a short training session about Cubism would facilitate object recognition in paintings by Picasso, Braque and Gris. Subjects, who had no formal art education, were presented with titled or untitled cubist paintings and scrambled images, and performed object recognition tasks. Relative to the control group, trained subjects recognized more objects in the paintings, their response latencies were significantly shorter, and they showed enhanced activation in the parahippocampal cortex, with a parametric increase in the amplitude of the fMRI signal as a function of the number of recognized objects. Moreover, trained subjects were slower to report not recognizing any familiar objects in the paintings and these longer response latencies were correlated with activation in a fronto-parietal network. These findings suggest that trained subjects adopted a visual search strategy and used contextual associations to perform the tasks. Our study supports the proactive brain framework, according to which the brain uses associations to generate predictions. PMID:20224810

  13. Painting with polygons: a procedural watercolor engine.

    PubMed

    DiVerdi, Stephen; Krishnaswamy, Aravind; Měch, Radomír; Ito, Daichi

    2013-05-01

    Existing natural media painting simulations have produced high-quality results, but have required powerful compute hardware and have been limited to screen resolutions. Digital artists would like to be able to use watercolor-like painting tools, but at print resolutions and on lower end hardware such as laptops or even slates. We present a procedural algorithm for generating watercolor-like dynamic paint behaviors in a lightweight manner. Our goal is not to exactly duplicate watercolor painting, but to create a range of dynamic behaviors that allow users to achieve a similar style of process and result, while at the same time having a unique character of its own. Our stroke representation is vector based, allowing for rendering at arbitrary resolutions, and our procedural pigment advection algorithm is fast enough to support painting on slate devices. We demonstrate our technique in a commercially available slate application used by professional artists. Finally, we present a detailed analysis of the different vector-rendering technologies available. PMID:23492376

  14. Comparative chromosome painting in Carnivora and Pholidota.

    PubMed

    Perelman, P L; Beklemisheva, V R; Yudkin, D V; Petrina, T N; Rozhnov, V V; Nie, W; Graphodatsky, A S

    2012-01-01

    The order of Carnivora has been very well characterized with over 50 species analyzed by chromosome painting and with painting probe sets made for 9 Carnivora species. Representatives of almost all families have been studied with few exceptions (Otariidae, Odobenidae, Nandiniidae, Prionodontidae). The patterns of chromosome evolution in Carnivora are discussed here. Overall, many Carnivora species retained karyotypes that only slightly differ from the ancestral carnivore karyotype. However, there are at least 3 families in which the ancestral carnivore karyotype has been severely rearranged - Canidae, Ursidae and Mephitidae. Here we report chromosome painting of yet another Carnivora species with a highly rearranged karyotype, Genetta pardina. Recurrent rearrangements make it difficult to define the ancestral chromosomal arrangement in several instances. Only 2 species of pangolins (Pholidota), a sister order of Carnivora, have been studied by chromosome painting. Future use of whole-genome sequencing data is discussed in the context of solving the questions that are beyond resolution of conventional banding techniques and chromosome painting.

  15. Laser cleaning treatment of burnt paintings

    NASA Astrophysics Data System (ADS)

    Antonopoulou-Athera, N.; Chatzitheodoridis, E.; Doulgerides, M.; Evangelatos, Ch.; Serafetinides, A. A.; Terlixi, A.

    2015-01-01

    Three samples taken from two paintings partly burned by fire are investigated for cleaning with lasers. The paintings belong to the collection of the National Gallery of Athens and were made by the great Greek artist Konstantinos Parthenis. To remove the damaged surface and achieve an acceptable restoration result, the optimum combination of fluence and wavelength are sought. Seven different wavelengths with a set of fluences where used, i.e., the five harmonics of a Nd:YAG laser (1064, 532, 355, 266, and 213 nm), a TEA 10.6 μm CO2 and a free running laser Er:YAG 2.94 μm. Characterization was performed prior and after the cleaning process by optical and electron microscopy and analysis (SEM/BSE EDS), as well as X-Ray Diffraction (XRD). The results of this work indicate that the wavelength in the visible spectrum (532 nm) with fluences between 0.1-0.4J/cm2 show the optimum cleaning. The optical microscopy observation shows that with these laser parameters the burnt layer was preferentially removed, exposing the original colors that Parthenis had used in these paintings. Electron microscopy imaging and chemical analysis revealed that the original texture and materials of these samples are preserved after irradiation. Since the damage varies along the surface of the painting, more experiments should be performed in order to find and optimize the full cleaning and characterization process for the homogeneous cleaning of the whole surface of the painting.

  16. Rotary concentrator followed by thermal or catalytic oxidation - a hybrid approach to economical styrene abatement

    SciTech Connect

    Gupta, A.

    1997-12-31

    There are varied challenges in deciding appropriate technology for styrene abatement. Due to high costs of using RTOs for styrene abatement the small businesses, which form the bulk of styrene emitters, are faced with economically difficult choices. The proposed Rotary Concentrator technology can reduce operating cost up to six times and reduce CO{sub 2} and NO{sub x} emissions by more than half over the currently preferred RTO technology. It is also less expensive in capital expenditure and its viability for styrene abatement has been sufficiently demonstrated by pilot studies in the US and existing installations overseas. In both cases styrene destruction of more than 95% was achieved.

  17. Preference for and discrimination of paintings by mice.

    PubMed

    Watanabe, Shigeru

    2013-01-01

    I measured preference for paintings (Renoir vs. Picasso or Kandinsky vs. Mondrian) in mice. In general mice did not display a painting preference except for two mice: one preferred Renoir to Picasso, and the other preferred Kandinsky to Mondrian. Thereafter, I examined discrimination of paintings with new mice. When exposure to paintings of one artist was associated with an injection of morphine (3.0 mg/kg), mice displayed conditioned preference for those paintings, showing discrimination of paintings by Renoir from those by Picasso, and paintings by Kandinsky from those by Mondrian after the conditioning. They also exhibited generalization of the preference to novel paintings of the artists. After conditioning with morphine for a set of paintings consisting of two artists, mice showed discrimination between two sets of paintings also from the two artists but not in association with morphine. These results suggest that mice can discriminate not only between an artist's style but also among paintings of the same artist. When mice were trained to discriminate a pair of paintings by Kandinsky and Renoir in an operant chamber equipped with a touch screen, they showed transfer of the discrimination to new pairs of the artists, but did not show transfer of discrimination of paintings by other artists, suggesting generalization.

  18. Preference for and Discrimination of Paintings by Mice

    PubMed Central

    Watanabe, Shigeru

    2013-01-01

    I measured preference for paintings (Renoir vs. Picasso or Kandinsky vs. Mondrian) in mice. In general mice did not display a painting preference except for two mice: one preferred Renoir to Picasso, and the other preferred Kandinsky to Mondrian. Thereafter, I examined discrimination of paintings with new mice. When exposure to paintings of one artist was associated with an injection of morphine (3.0 mg/kg), mice displayed conditioned preference for those paintings, showing discrimination of paintings by Renoir from those by Picasso, and paintings by Kandinsky from those by Mondrian after the conditioning. They also exhibited generalization of the preference to novel paintings of the artists. After conditioning with morphine for a set of paintings consisting of two artists, mice showed discrimination between two sets of paintings also from the two artists but not in association with morphine. These results suggest that mice can discriminate not only between an artist’s style but also among paintings of the same artist. When mice were trained to discriminate a pair of paintings by Kandinsky and Renoir in an operant chamber equipped with a touch screen, they showed transfer of the discrimination to new pairs of the artists, but did not show transfer of discrimination of paintings by other artists, suggesting generalization. PMID:23762346

  19. [Disease in Velázquez' painting].

    PubMed

    Schüller Pérez, A

    2000-01-01

    A short biographical abstract of Painter Velázquez and his artistical and cultural background with relation to this own time is given. His whole work and of the court and official jobs he had has, been analysed. Together with his artistical vocation and great capacity and aptitude for painting, he felt the ambition to seek a position of nobility. A peculiar research of the pathological aspects appearing in his pictures has been made, regardless of the technical characteristics of his painting and style. For this purpose, his paintings have been classified in still lives, religious pictures, mythological pictures, portraits of royal male and female family members, portraits of ordinary people, big peoples such as Las Lanzas, Las Hilanderas and Las Meninas, etc., to conclude with the really singular group of buffoons, dwarfs, jesters and mad people. The pathological issues have been commented. A list of bibliographical references is also added.

  20. One year of Puma Painting: site experiences

    NASA Astrophysics Data System (ADS)

    Stein, Matthew R.

    1999-11-01

    The PumaPaint project is a web robot that allows users to create original artwork on the World Wide Web. The site allows control of a PUMA 760 robot equipped with four paintbrushes; jars of red, green, blue and yellow paint and white paper attached to an easel. Users must download a JavaTM interface allowing interactive control of the robot. This interface contains two windows showing live camera views of the work site and various controls for connecting and disconnecting to the robot, viewing the task status and controlling the painting task. During the first year of operation of the site, June 3rd, 1998 to June 2nd 1999, approximately 5,000 users produced 390 canvases. This paper presents summary data from one year of operation, discusses the author's experiences in operating the site and examines some of the artwork produced.

  1. Toward a behavioral toxicology of paint thinner.

    PubMed

    Colotla, V A; Lorenzana-Jiménez, M; Rodríguez, R

    1980-01-01

    Few experiments have been carried out to evaluate the effects of toxic industrial substances such as the solvents on operant behavior. Laboratory rats trained in a mult FR DRL reinforcement schedule showed a differential impairment in performance when exposed to various doses of paint thinner in the experimental chamber, the FR performance being more sensitive to the solvent than DRL responding. Another study of rats working under a FI schedule suggested that the effects of paint thinner are rate-dependent, a finding which suggests a similarity of thinner with the amphetamines in regard to the behavioral effect. Two other experiments addressed to the behavioral effects of chronic exposure to the solvent showed a decrease in locomotor activity and an impaired acquisition of a complex temporal discrimination task in laboratory rats exposed to paint thinner during four, eight of sixteen weeks. These findings are suggestive of brain dysfunction associated with thinner inhalation but further experiments are needed for more definite conclusions. PMID:7442918

  2. Focal cerebral lesions and painting abilities.

    PubMed

    Mazzucchi, Anna; Sinforiani, Elena; Boller, François

    2013-01-01

    Focal lesions such as strokes significantly affect painting production in the vast majority of artists. In particular, painters, when they resume painting, show changes in their painting style. In exceptional cases, there may be an apparent improvement in style, but in most cases, the changes represent nothing short of deterioration. This, however, varies according to the hemisphere affected. Painters with left-hemisphere lesions tend to show an inability to deal adequately with perspective and also tend to use simplified colors with fewer nuances. One often witnesses an evolution toward simpler, often "naïve" techniques, and at times rigid geometric repetitive features. Painters with right-hemisphere lesions also become unable to represent tridimensionality. In addition, their figures are often drawn in very summary fashion, with lack of coordination between volumes and space and a chromatic impoverishment; their main problem, however, is visuospatial, leading to neglect of the left side of the canvas.

  3. Hierarchical Micro-Nano Coatings by Painting

    NASA Astrophysics Data System (ADS)

    Kirveslahti, Anna; Korhonen, Tuulia; Suvanto, Mika; Pakkanen, Tapani A.

    2016-03-01

    In this paper, the wettability properties of coatings with hierarchical surface structures and low surface energy were studied. Hierarchically structured coatings were produced by using hydrophobic fumed silica nanoparticles and polytetrafluoroethylene (PTFE) microparticles as additives in polyester (PES) and polyvinyldifluoride (PVDF). These particles created hierarchical micro-nano structures on the paint surfaces and lowered or supported the already low surface energy of the paint. Two standard application techniques for paint application were employed and the presented coatings are suitable for mass production and use in large surface areas. By regulating the particle concentrations, it was possible to modify wettability properties gradually. Highly hydrophobic surfaces were achieved with the highest contact angle of 165∘. Dynamic contact angle measurements were carried out for a set of selected samples and low hysteresis was obtained. Produced coatings possessed long lasting durability in the air and in underwater conditions.

  4. The Actinobacterial Colonization of Etruscan Paintings

    PubMed Central

    Diaz-Herraiz, Marta; Jurado, Valme; Cuezva, Soledad; Laiz, Leonila; Pallecchi, Pasquino; Tiano, Piero; Sanchez-Moral, Sergio; Saiz-Jimenez, Cesareo

    2013-01-01

    The paintings from Tomba della Scimmia, in Tuscany, are representative of the heavy bacterial colonization experienced in most Etruscan necropolises. The tomb remained open until the late 70′s when it was closed because of severe deterioration of the walls, ceiling and paintings after decades of visits. The deterioration is the result of environmental changes and impacts suffered since its discovery in 1846. We show scanning electron microscopy and molecular studies that reveal the extent and nature of the biodeterioration. Actinobacteria, mainly Nocardia and Pseudonocardia colonize and grow on the tomb walls and this process is linked to the availability of organic matter, phyllosilicates (e.g. clay minerals) and iron oxides. Nocardia is found metabolically active in the paintings. The data confirm the specialization of the genera Nocardia and Pseudonocardia in the colonization of subterranean niches. PMID:23486535

  5. Water-Based Pressure-Sensitive Paints

    NASA Technical Reports Server (NTRS)

    Jordan, Jeffrey D.; Watkins, A. Neal; Oglesby, Donald M.; Ingram, JoAnne L.

    2006-01-01

    Water-based pressure-sensitive paints (PSPs) have been invented as alternatives to conventional organic-solvent-based pressure-sensitive paints, which are used primarily for indicating distributions of air pressure on wind-tunnel models. Typically, PSPs are sprayed onto aerodynamic models after they have been mounted in wind tunnels. When conventional organic-solvent-based PSPs are used, this practice creates a problem of removing toxic fumes from inside the wind tunnels. The use of water-based PSPs eliminates this problem. The waterbased PSPs offer high performance as pressure indicators, plus all the advantages of common water-based paints (low toxicity, low concentrations of volatile organic compounds, and easy cleanup by use of water).

  6. Visual comparison testing of automotive paint simulation

    NASA Astrophysics Data System (ADS)

    Meyer, Gary; Fan, Hua-Tzu; Seubert, Christopher; Evey, Curtis; Meseth, Jan; Schnackenberg, Ryan

    2015-03-01

    An experiment was performed to determine whether typical industrial automotive color paint comparisons made using real physical samples could also be carried out using a digital simulation displayed on a calibrated color television monitor. A special light booth, designed to facilitate evaluation of the car paint color with reflectance angle, was employed in both the real and virtual color comparisons. Paint samples were measured using a multi-angle spectrophotometer and were simulated using a commercially available software package. Subjects performed the test quicker using the computer graphic simulation, and results indicate that there is only a small difference between the decisions made using the light booth and the computer monitor. This outcome demonstrates the potential of employing simulations to replace some of the time consuming work with real physical samples that still characterizes material appearance work in industry.

  7. Analysis of mural paintings in Istria.

    PubMed

    Mazzocchin, G A; Rudello, D; Maraković, N; Marić, I

    2007-08-01

    Fragments of wall paintings from Istria, coming from the Basilica of Guran near Vodnjan, from the cemeterial Church of Saint Simeon in Guran and from the Benedictine monastery of Santa Maria Alta near Bale were studied. The analytical instrumental techniques used were Optical Microscopy, Scanning Electron Microscopy equipped with an EDS microanalysis detector, X Ray diffraction, FTIR infrared Spectroscopy and Raman Spectroscopy. Red and yellow pigments used in Guran and Bale have bean derived from red and yellow istrian bauxites, as already demonstrated for works from 11th to 15th century. The blue pigment found in the paintings of the Bale Chapel is a lapislazzuli blue; this fact confirms the literature data referring to the period from 11th to the 16th century. The materials and pigments used at Bale and Guran fit with the Istrian tradition and history of painting going back to the first Carolingian period.

  8. The actinobacterial colonization of Etruscan paintings.

    PubMed

    Diaz-Herraiz, Marta; Jurado, Valme; Cuezva, Soledad; Laiz, Leonila; Pallecchi, Pasquino; Tiano, Piero; Sanchez-Moral, Sergio; Saiz-Jimenez, Cesareo

    2013-01-01

    The paintings from Tomba della Scimmia, in Tuscany, are representative of the heavy bacterial colonization experienced in most Etruscan necropolises. The tomb remained open until the late 70's when it was closed because of severe deterioration of the walls, ceiling and paintings after decades of visits. The deterioration is the result of environmental changes and impacts suffered since its discovery in 1846. We show scanning electron microscopy and molecular studies that reveal the extent and nature of the biodeterioration. Actinobacteria, mainly Nocardia and Pseudonocardia colonize and grow on the tomb walls and this process is linked to the availability of organic matter, phyllosilicates (e.g. clay minerals) and iron oxides. Nocardia is found metabolically active in the paintings. The data confirm the specialization of the genera Nocardia and Pseudonocardia in the colonization of subterranean niches.

  9. Gloss paints in late paintings by Francis Picabia: a multi-analytical study

    NASA Astrophysics Data System (ADS)

    Kokkori, Maria; Hubert, Marie-Odile; Balcar, Nathalie; Barabant, Gilles; Sutherland, Ken; Casadio, Francesca

    2016-01-01

    In this paper, a multi-analytical approach for the study of the materials used by Francis Picabia in two paintings dating from 1949 and 1950 is reported, with a particular reference to the possible use of enamel paints. The study is complemented by analysis of paints that had the appearance of glossy enamel sampled from the artist's easel in the collection of the Comité Francis Picabia. Analysis with Fourier transform infrared spectroscopy, pyrolysis gas chromatography mass spectrometry with thermally assisted hydrolysis and methylation (THM-Py-GCMS) and scanning electron microscopy coupled with energy-dispersive X-ray spectroscopy revealed that only few paints match the composition of historical reference samples of Ripolin enamels, while the majority of the glossy paints sampled likely consist of mixtures of binders and varnishes made by the artist. This study confirms the importance of scientific testing and comparison with reference materials, when determining artists' use of enamel paints. Results should be interpreted in the context of documentary/historical evidence, for a more informed characterization of oleoresinous paint media.

  10. Will lead-based anodes ever be replaced in aqueous electrowinning?

    NASA Astrophysics Data System (ADS)

    Moats, Michael S.

    2008-10-01

    Lead anodes have been employed in commercial aqueous electrowinning for close to a century. In the past three decades, several attempts have been made to replace lead anodes with other materials. For the most part, the use of other anodes, particularly coated titanium anodes (CTAs), has been limited to niche electrowinning applications. This article will review electrowinning processes that employ coated titanium anodes and evaluate metal electrowinning systems from a coated titanium anode perspective, including recent attempts at replacing lead-based anodes. Finally, a general economic evaluation of CTAs and lead anodes will be presented and areas for future research will be identified that could hasten the replacement of lead-based anodes in aqueous electrowinning systems.

  11. Breast Mass in a Rubens Painting

    PubMed Central

    Lazzeri, Davide; Lippi, Donatella; Castello, Manuel Francisco; Weisz, George M.

    2016-01-01

    Deformity of the breast and axilla observed in famous paintings is a fascinating field for the medico-artists. The attempt of a retrospective diagnosis of breast tumors is highly challenging. This paper deals with a Rubens painting portraying the heroine Judith with a visible but previously unreported left breast mass. Though speculative, the present medico-artistic diagnosis is of a tumor likely to be of benign nature. It is of interest that the present case is the sixth breast disease discovered in Rubens’s works. PMID:27101221

  12. Breast Mass in a Rubens Painting.

    PubMed

    Lazzeri, Davide; Lippi, Donatella; Castello, Manuel Francisco; Weisz, George M

    2016-04-19

    Deformity of the breast and axilla observed in famous paintings is a fascinating field for the medico-artists. The attempt of a retrospective diagnosis of breast tumors is highly challenging. This paper deals with a Rubens painting portraying the heroine Judith with a visible but previously unreported left breast mass. Though speculative, the present medico-artistic diagnosis is of a tumor likely to be of benign nature. It is of interest that the present case is the sixth breast disease discovered in Rubens's works.

  13. Health hazards in drawing and painting.

    PubMed

    Spandorfer, M; Curtiss, D; Snyder, J W

    2001-01-01

    Most health hazards in drawing and painting fall into two primary categories: volatile organic solvents used in many painting mediums and fixatives for dry drawing mediums; and respirable powders and dusts such as powdered pigments and dyes, which may be toxic and/or suspected or known carcinogens. User safeguards, such as appropriate ventilation and protective attire, and protection of the environment through careful emission and waste disposal, can be readily implemented with the education of artists and their employers. This chapter succinctly outlines the risk factors, symptomatology, and remedies to assist medical professionals in providing diagnosis and treatment.

  14. 1. GENERAL VIEW. OVERHANG, PAINTED RED, HAS VERTICAL SIDING AND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. GENERAL VIEW. OVERHANG, PAINTED RED, HAS VERTICAL SIDING AND FADED PAINTINGS OF FARM ANIMALS: COW, DONKEYS AND HORSE. - De Turck House, Barn, State Route 662 vicinity, Oley Township, Oley, Berks County, PA

  15. 33 CFR 118.140 - Painting bridge piers.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... BRIDGE LIGHTING AND OTHER SIGNALS § 118.140 Painting bridge piers. The District Commander may require painting the sides of bridge channel piers below the superstructure facing traffic white or yellow...

  16. 33 CFR 118.140 - Painting bridge piers.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... BRIDGE LIGHTING AND OTHER SIGNALS § 118.140 Painting bridge piers. The District Commander may require painting the sides of bridge channel piers below the superstructure facing traffic white or yellow...

  17. BICARBONATE OF SODA BLASTING TECHNOLOGY FOR AIRCRAFT WHEEL PAINTING

    EPA Science Inventory

    This evaluation addressed product quality, waste reduction/pollution prevention and economics in replacing chemical solvent strippers with a bicarbonate of soda blasting technology for removal of paint from aircraft wheels. The evaluation was conducted in the Paint Stripping Sho...

  18. 5. Historic American Buildings Survey Photo from Painting California Historical ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. Historic American Buildings Survey Photo from Painting California Historical Society Original: 1868 (Painting) Re-photo: January 1940 VIEW FROM WEST (AFTER EARTHQUAKE OF 1868) - Mission San Jose de Guadalupe, Mission & Washington Boulevards, Fremont, Alameda County, CA

  19. Miniature paint-spray gun for recessed areas

    NASA Technical Reports Server (NTRS)

    Vanasse, M. A.

    1968-01-01

    Miniature spray gun regulates paints and other liquids to spray at close range, facilitating spraying of remote or recessed areas. Individual valves for regulating air pressure and paint maximizes atomization for low pressure spraying.

  20. 1. GENERAL VIEW. NOTE STONE END, PAINTED DOOR AND WINDOW ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. GENERAL VIEW. NOTE STONE END, PAINTED DOOR AND WINDOW 'HEADS', HEX SIGNS (BLACK AND WHITE COLORS) AND PAINTED SCALLOP PATTERN (ON BOTTOM OF OVERHANG) - Decorated Red Barn, Alburtis, Lehigh County, PA