Sample records for abdominal circulatory pump

  1. [Importance of mechanical assist devices in acute circulatory arrest].

    PubMed

    Ferrari, Markus Wolfgang

    2016-03-01

    Mechanical assist devices are indicated for hemodynamic stabilization in acute circulatory arrest if conventional means of cardiopulmonary resuscitation are unable to re-establish adequate organ perfusion. Their temporary use facilitates further diagnostic and therapeutic options in selected patients, e.g. coronary angiography followed by revascularization.External thorax compression devices allow sufficient cardiac massage in case of preclinical or in-hospital circulatory arrest, especially under complex transfer conditions. These devices perform standardized thorax compressions at a rate of 80-100 per minute. Invasive mechanical support devices are used in the catheter laboratory or in the intensive care unit. Axial turbine pumps, e.g. the Impella, continuously pump blood from the left ventricle into the aortic root. The Impella can also provide right ventricle support by pumping blood from the vena cava into the pulmonary artery. So-called emergency systems or ECMO devices consist of a centrifugal pump and a membrane oxygenator allowing complete takeover of cardiac and pulmonary functions. Withdrawing blood from the right atrium and vena cava, oxygenated blood is returned to the abdominal aorta. Isolated centrifugal pumps provide left heart support without an oxygenator after transseptal insertion of a venous cannula into the left atrium.Mechanical assist devices are indicated for acute organ protection and hemodynamic stabilization for diagnostic and therapeutic measures as well as bridge to myocardial recovery. Future technical developments and better insights into the pathophysiology of mechanical circulatory support will broaden the spectrum of indications of such devices in acute circulatory arrest.

  2. A seal-less centrifugal pump (Baylor Gyro Pump) for application to long-term circulatory support.

    PubMed

    Minato, N; Sakuma, I; Sasaki, T; Shiono, M; Ohara, Y; Takatani, S; Noon, G P; Nosé, Y

    1993-01-01

    We are developing a new centrifugal pump, the Baylor Gyro Centrifugal Pump (Gyro Pump), which can function for more than 2 weeks. The concept of the Gyro Pump is that a one-piece rotor-impeller with embedded permanent magnets, driven directly by a brushless direct current motor stator placed outside, rotates like a "gyroscope," and the rotor-impeller is supported by one pivot bearing at the bottom in accordance with the gyroscopic principle. This concept enables us to eliminate a driving shaft and a seal between the driving shaft and the blood chamber, which results in extending the life of the centrifugal pump. The blood passes through the space between the motor stator and the rotor to the impeller portion. In this preliminary phase, two pivot bearings were applied to support the rotor-impeller at the top and the bottom inside the blood chamber. Both pivot bearings showed less blood trauma and less thrombogenicity in in vitro and in vivo studies. The Gyro Pump is a promising second-generation centrifugal pump for long-term circulatory support in the near future.

  3. Baylor Gyro Pump: a completely seal-less centrifugal pump aiming for long-term circulatory support.

    PubMed

    Ohara, Y; Sakuma, I; Makinouchi, K; Damm, G; Glueck, J; Mizuguchi, K; Naito, K; Tasai, K; Orime, Y; Takatani, S

    1993-07-01

    A seal-less centrifugal pump aiming for long-term circulatory support has been developed. In this model, shaft seals that cause thrombus formation and blood leakage were eliminated. A brushless direct current motor was incorporated as a driving unit, and pivot bearings were used to support the impeller. With reference to its motor-driven system, this pump was named the M-Gyro Pump. The first model (M1) yielded an index of hemolysis of 0.005 g/100 L using bovine blood and demonstrated satisfactory performance as a right heart assist for 2 days (4 L/min, 60 mm Hg, 1,800 rpm). The second model (M2) has been developed for left heart assist by employing a stronger motor. The pump capacity was improved to 6 L/min against 240 mm Hg at 1,800 rpm, but significant heat generation was observed. By optimization of motor efficiency, the M2 model can be improved to meet the requirements of a pump for left heart assist.

  4. Development of the Baylor-Nikkiso centrifugal pump with a purging system for circulatory support.

    PubMed

    Naito, K; Miyazoe, Y; Aizawa, T; Mizuguchi, K; Tasai, K; Ohara, Y; Orime, Y; Glueck, J; Takatani, S; Noon, G P

    1993-07-01

    The Baylor-Nikkiso centrifugal pump is a magnetically coupled system with a V-ring seal separating the pump and the actuator chamber. To prevent thrombus formation behind the impeller and to extend the life of the pump to 2 weeks of continuous operation, we incorporated a purging chamber behind the V-ring seal. An external pump connected to this purging chamber infused fluid at a constant rate to wash the shaft-seal area. To evaluate the effectiveness of the purging system, we have carried out biventricular bypass experiments using calves. The purging system was successful in reducing the level of thrombus formation after 2 weeks of operation. The results of these studies confirmed that the Baylor-Nikkiso centrifugal pump with this purging system is suitable for at least 2 weeks of continuous operation as a circulatory support system.

  5. EVAHEART: an implantable centrifugal blood pump for long-term circulatory support.

    PubMed

    Yamazaki, Kenji; Kihara, Shinichiro; Akimoto, Takehide; Tagusari, Osamu; Kawai, Akihiko; Umezu, Mitsuo; Tomioka, Jun; Kormos, Robert L; Griffith, Bartley P; Kurosawa, Hiromi

    2002-11-01

    We developed "EVAHEART": a compact centrifugal blood pump system as an implantable left ventricular assist device for long-term circulatory support. The 55 x 64 mm pump is made from pure titanium, and weighs 370 g. The entire blood-contacting surface is covered with an anti-thrombogenic coating of diamond like carbon (DLC) or 2-methacryloyloxyethyl phosphorylcholine (MPC) to improve blood compatibility. Flows exceeding 12 L/min against 100 mmHg pressure at 2600 rpm was measured. A low-temperature mechanical seal with recirculating cooling system is used to seal the shaft. EVAHEART demonstrated an acceptably low hemolysis rate with normalized index of hemolysis of 0.005 +/- 0.002 g/100L. We evaluated the pump in long-term in-vivo experiments with seven calves. Via left thoracotomy, we conducted left ventricular apex-descending aorta bypass, placing the pump in the left thoracic cavity. Pump flow rates was maintained at 5-9 L/min, pump power consumption remained stable at 9-10 W in all cases, plasma free Hb levels were less than 15 mg/dl, and the seal system showed good seal capability throughout the experiments. The calves were sacrificed on schedule on postoperative day 200, 222, 142, 90, 151, 155, and 133. No thrombi formed on the blood contacting surface with either the DLC or MPC coating, and no major organ thromboembolisms occurred except for a few small renal infarcts. EVAHEART centrifugal blood pump demonstrated excellent performance in long-term in-vivo experiments.

  6. Mechanical circulatory support of a univentricular Fontan circulation with a continuous axial-flow pump in a piglet model.

    PubMed

    Wei, Xufeng; Sanchez, Pablo G; Liu, Yang; Li, Tieluo; Watkins, A Claire; Wu, Zhongjun J; Griffith, Bartley P

    2015-01-01

    Despite the significant contribution of the Fontan procedure to the therapy of complex congenital heart diseases, many patients progress to failure of their Fontan circulation. The use of ventricular assist devices to provide circulatory support to these patients remains challenging. In the current study, a continuous axial-flow pump was used to support a univentricular Fontan circulation. A modified Fontan circulation (atrio-pulmonary connection) was constructed in six Yorkshire piglets (8-14 kg). A Dacron conduit (12 mm) with two branches was constructed to serve as a complete atrio-pulmonary connection without the use of cardiopulmonary bypass. The Impella pump was inserted into the conduit through an additional Polytetrafluoroethylene (PTFE) graft in five animals. Hemodynamic data were collected for 6 hours under the supported Fontan circulation. The control animal died after initiating the Fontan circulation independent of resuscitation. Four pump supported animals remained hemodynamically stable for 6 hours with pump speeds between 18,000 rpm and 22,000 rpm (P1-P3). Oxygen saturation was maintained between 95% and 100%. Normal organ perfusion was illustrated by blood gas analysis and biochemical assays. A continuous axial-flow pump can be used for temporal circulatory support to the failing Fontan circulation as "bridge" to heart transplantation or recovery.

  7. Current risks of HeartMate II pump thrombosis: Non-parametric analysis of Interagency Registry for Mechanically Assisted Circulatory Support data.

    PubMed

    Smedira, Nicholas G; Blackstone, Eugene H; Ehrlinger, John; Thuita, Lucy; Pierce, Christopher D; Moazami, Nader; Starling, Randall C

    2015-12-01

    Data from 3 institutions revealed an abrupt increase in HeartMate II (Thoratec) pump thrombosis starting in 2011, associated with 48% mortality at 6 months without transplantation or pump exchange. We sought to discover if the increase occurred nationwide in Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) data, and if so (1) determine if accelerated risk continued, (2) identify predictors, (3) investigate institutional variability, and (4) assess mortality after pump thrombosis. From April 2008 to June 2014, 11,123 HeartMate II devices were implanted at 146 institutions. Machine learning, non-parametric Random Forests for Survival was used to explore risk-adjusted thrombosis based on 87 pre-implant and implant variables, including implant date. A total of 995 pumps thrombosed, with risk peaking within weeks of implant. The risk-adjusted increase in pump thrombosis began in 2010, reached a maximum in 2012, and then plateaued at a level that was 3.3-times higher than pre-2010. Pump exchange, younger age, and larger body mass index were important predictors, and institutional variability was largely explained by implant date, patient profile, and duration of support. The probability of death within 3 months after pump thrombosis was 24%. Accelerated risk of HeartMate II thrombosis was confirmed by Interagency Registry for Mechanically Assisted Circulatory Support data, with risk subsequently leveling at a risk-adjusted rate higher than observed pre-2010. This elevated thrombosis risk emphasizes the need for improved mechanical circulatory support systems and post-market surveillance of adverse events. Clinicians cognizant of these new data should incorporate them into their and their patients' expectations and understanding of risks relative to those of transplantation and continued medical therapy. Copyright © 2015 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  8. Circulatory support for OPCAB procedures.

    PubMed

    Mueller, Xavier M; von Segesser, Ludwig K

    2002-07-01

    During off-pump coronary artery bypass grafting (OPCAB) which allows complete revascularization through a median sternotomy, revascularization of the lateral and posterior walls requires the verticalization of the heart, which may cause haemodynamic disturbance. This concern has stimulated the development of circulatory support with mini-pumps. Initially, these pumps were designed for the right side of the heart, which was found to be the main contributor to haemodynamic instability under experimental conditions. The three types of mini-pumps that have been developed so far - two for the right side of the heart and one for both sides - are reviewed as well as a new concept of integrated cardiopulmonary bypass (CPB) circuit with reduced surface and priming volume. However, with increasing experience and improved methods of exposition, OPCAB has become a procedure that can be performed without support in the majority of the cases. Nevertheless, the concept of miniaturization and the possibility to insert these devices through a peripheral access has opened the way to new indications, mainly short-term circulatory support for acute heart failure. This development is welcome in a field where available devices are invasive and plagued with a heavy morbidity.

  9. A first-in-man study of the Reitan catheter pump for circulatory support in patients undergoing high-risk percutaneous coronary intervention.

    PubMed

    Smith, Elliot J; Reitan, Oyvind; Keeble, Thomas; Dixon, Kerry; Rothman, Martin T

    2009-06-01

    To investigate the safety of a novel percutaneous circulatory support device during high-risk percutaneous coronary intervention (PCI). The Reitan catheter pump (RCP) consists of a catheter-mounted pump-head with a foldable propeller and surrounding cage. Positioned in the descending aorta the pump creates a pressure gradient, reducing afterload and enhancing organ perfusion. Ten consecutive patients requiring circulatory support underwent PCI; mean age 71 +/- 9; LVEF 34% +/- 11%; jeopardy score 8 +/- 2.3. The RCP was inserted via the femoral artery. Hemostasis was achieved using Perclose sutures. PCI was performed via the radial artery. Outcomes included in-hospital death, MI, stroke, and vascular injury. Hemoglobin (Hb), free plasma Hb (fHb), platelets, and creatinine (cre) were measured pre PCI and post RCP removal. The pump was inserted and operated successfully in 9/10 cases (median 79 min). Propeller rotation at 10,444 +/- 1,424 rpm maintained an aortic gradient of 9.8 +/- 2 mm Hg. Although fHb increased, there was no significant hemolysis (4.7 +/- 2.4 mg/dl pre vs. 11.9 +/- 10.5 post, P = 0.04, reference 20 mg/dl). Platelets were unchanged (pre 257 +/- 74 x 10(9) vs. 245 +/- 63, P = NS). Renal function improved (cre pre 110 +/- 27 micromol/l vs. 99 +/- 28, P = 0.004). The RCP was not used in one patient following femoral introducer sheath related aortic dissection. All PCI procedures were successful with no deaths or strokes, one MI, and no vascular complications following pump removal. The RCP can be used safely in high-risk PCI patients. This device may be an alternative to other percutaneous systems when substantial cardiac support is needed. (c) 2009 Wiley-Liss, Inc.

  10. US FDA perspective on regulatory issues affecting circulatory assist devices.

    PubMed

    Sapirstein, Wolf; Chen, Eric; Swain, Julie; Zuckerman, Bram

    2006-11-01

    There has been a rapid development in mechanical circulatory support systems in the decade since the US FDA first approved a mechanical device to provide the circulatory support lacking from a failing heart. Devices are presently approved for marketing by the FDA to replace a failing ventricle, the Ventricular Assist Device or the entire heart, Total Artificial Heart. Contemporaneous with, and permitted by, improvement in technology and design, devices have evolved from units located extracorporeally to paracorporeal systems and totally implanted devices. Clinical studies have demonstrated a parallel improvement in the homeostatic adequacy of the circulatory support provided. Thus, while the circulatory support was initially tolerated for short periods to permit recovery of cardiac function, this technology eventually provided effective circulatory support for increasing periods that permitted the FDA to approve devices for bridging patients in end-stage cardiac failure awaiting transplant and eventually a device for destination therapy where patients in end-stage heart failure are not cardiac transplant candidates. The approved devices have relied on displacement pumps that mimic the pulsatility of the physiological system. Accelerated development of more compact devices that rely on alternative pump mechanisms have challenged both the FDA and device manufacturers to assure that the regulatory requirements for safety and effectiveness are met for use of mechanical circulatory support systems in expanded target populations. An FDA regulatory perspective is reviewed of what can be a potentially critical healthcare issue.

  11. Temporary Mechanical Circulatory Support: A Review of the Options, Indications, and Outcomes

    PubMed Central

    Gilotra, Nisha A; Stevens, Gerin R

    2014-01-01

    Cardiogenic shock remains a challenging disease entity and is associated with significant morbidity and mortality. Temporary mechanical circulatory support (MCS) can be implemented in an acute setting to stabilize acutely ill patients with cardiomyopathy in a variety of clinical situations. Currently, several options exist for temporary MCS. We review the indications, contraindications, clinical applications, and evidences for a variety of temporary circulatory support options, including the intra-aortic balloon pump (IABP), extracorporeal membrane oxygenation (ECMO), CentriMag blood pump, and percutaneous ventricular assist devices (pVADs), specifically the TandemHeart and Impella. PMID:25674024

  12. Improving the Outcomes of Organs Obtained From Controlled Donation After Circulatory Death Donors Using Abdominal Normothermic Regional Perfusion.

    PubMed

    Miñambres, E; Suberviola, B; Dominguez-Gil, B; Rodrigo, E; Ruiz-San Millan, J C; Rodríguez-San Juan, J C; Ballesteros, M A

    2017-08-01

    The use of donation after circulatory death (DCD) has increased significantly during the past decade. However, warm ischemia results in a greater risk for transplantation. Indeed, controlled DCD (cDCD) was associated with inferior outcomes compared with donation after brain death. The use of abdominal normothermic regional perfusion (nRP) to restore blood flow before organ recovery in cDCD has been proposed as better than rapid recovery to reverse the effect of ischemia and improve recipients' outcome. Here, the first Spanish series using abdominal nRP as an in situ conditioning method is reported. A specific methodology to avoid restoring circulation to the brain after death determination is described. Twenty-seven cDCD donors underwent abdominal nRP during at least 60 min. Thirty-seven kidneys, 11 livers, six bilateral lungs, and one pancreas were transplanted. The 1-year death-censored kidney survival was 91%, and delayed graft function rate was 27%. The 1-year liver survival rate was 90.1% with no cases of ischemic cholangiopathy. Transplanted lungs and pancreas exhibited primary function. The use of nRP may represent an advance to increase the number and quality of grafts in cDCD. Poor results in cDCD livers could be reversed with nRP. Concerns about restoring brain circulation after death are easily solved. © 2017 The American Society of Transplantation and the American Society of Transplant Surgeons.

  13. Continuous-infusion local anesthetic pain pump use and seroma formation with abdominal procedures: is there a correlation?

    PubMed

    Smith, Melissa M; Hovsepian, Raffi V; Markarian, Mark K; Degelia, Amber L; Paul, Malcolm D; Evans, Gregory R D; Wirth, Garrett A

    2008-11-01

    Seroma formation is the most commonly occurring complication in plastic surgery abdominal procedures. Continuous local anesthetic pain pump delivery systems are often used to decrease postoperative pain. An unreported concern with use of these devices in abdominal procedures is the effect of continuous fluid infiltration of the surgical site and a possible increase in the incidence of seroma formation. The authors performed a retrospective chart review to evaluate all patients (n = 159) who underwent abdominal procedures (abdominoplasty, panniculectomy, and transverse rectus abdominis myocutaneous flap harvest) over a 3-year period. Patient charts were evaluated for sex, age, body mass index, procedure performed, surgeon, operation length, pain pump use, postoperative seroma formation, and any complications. In cases with pain pump use, catheter placement location, anesthetic medication and strength, continuous-infusion rate, and duration of pain pump use were also reviewed. If a postoperative seroma formation was identified, treatment and outcomes were also recorded. The overall seroma formation rate was 11.3 percent (18 of 159 patients). Other complications occurred at a rate of 2.5 percent (four of 159). The incidence of seroma was 11.0 percent (11 of 100) in patients with pain pump use versus 11.9 percent (7 of 59) in those who did not use a pain pump. There was no statistically significant difference (p = 0.9) in the incidence of seroma formation between those who did and did not use a pain pump device. There was no correlation between increased rate of seroma formation and use of a continuous-infusion local anesthetic pain pump system in our patient population.

  14. A microfluidic circulatory system integrated with capillary-assisted pressure sensors.

    PubMed

    Chen, Yangfan; Chan, Ho Nam; Michael, Sean A; Shen, Yusheng; Chen, Yin; Tian, Qian; Huang, Lu; Wu, Hongkai

    2017-02-14

    The human circulatory system comprises a complex network of blood vessels interconnecting biologically relevant organs and a heart driving blood recirculation throughout this system. Recreating this system in vitro would act as a bridge between organ-on-a-chip and "body-on-a-chip" and advance the development of in vitro models. Here, we present a microfluidic circulatory system integrated with an on-chip pressure sensor to closely mimic human systemic circulation in vitro. A cardiac-like on-chip pumping system is incorporated in the device. It consists of four pumping units and passive check valves, which mimic the four heart chambers and heart valves, respectively. Each pumping unit is independently controlled with adjustable pressure and pump rate, enabling users to control the mimicked blood pressure and heartbeat rate within the device. A check valve is located downstream of each pumping unit to prevent backward leakage. Pulsatile and unidirectional flow can be generated to recirculate within the device by programming the four pumping units. We also report an on-chip capillary-assisted pressure sensor to monitor the pressure inside the device. One end of the capillary was placed in the measurement region, while the other end was sealed. Time-dependent pressure changes were measured by recording the movement of the liquid-gas interface in the capillary and calculating the pressure using the ideal gas law. The sensor covered the physiologically relevant blood pressure range found in humans (0-142.5 mmHg) and could respond to 0.2 s actuation time. With the aid of the sensor, the pressure inside the device could be adjusted to the desired range. As a proof of concept, human normal left ventricular and arterial pressure profiles were mimicked inside this device. Human umbilical vein endothelial cells (HUVECs) were cultured on chip and cells can respond to mechanical forces generated by arterial-like flow patterns.

  15. Mechanical Circulatory Support Devices for Acute Right Ventricular Failure.

    PubMed

    Kapur, Navin K; Esposito, Michele L; Bader, Yousef; Morine, Kevin J; Kiernan, Michael S; Pham, Duc Thinh; Burkhoff, Daniel

    2017-07-18

    Right ventricular (RV) failure remains a major cause of global morbidity and mortality for patients with advanced heart failure, pulmonary hypertension, or acute myocardial infarction and after major cardiac surgery. Over the past 2 decades, percutaneously delivered acute mechanical circulatory support pumps specifically designed to support RV failure have been introduced into clinical practice. RV acute mechanical circulatory support now represents an important step in the management of RV failure and provides an opportunity to rapidly stabilize patients with cardiogenic shock involving the RV. As experience with RV devices grows, their role as mechanical therapies for RV failure will depend less on the technical ability to place the device and more on improved algorithms for identifying RV failure, patient monitoring, and weaning protocols for both isolated RV failure and biventricular failure. In this review, we discuss the pathophysiology of acute RV failure and both the mechanism of action and clinical data exploring the utility of existing RV acute mechanical circulatory support devices. © 2017 American Heart Association, Inc.

  16. Is our heart a well-designed pump? The heart along animal evolution.

    PubMed

    Bettex, Dominique A; Prêtre, René; Chassot, Pierre-Guy

    2014-09-07

    A carrier system for gases and nutrients became mandatory when primitive animals grew larger and developed different organs. The first circulatory systems are peristaltic tubes pushing slowly the haemolymph into an open vascular tree without capillaries (worms). Arthropods developed contractile bulges on the abdominal aorta assisted by accessory hearts for wings or legs and by abdominal respiratory motions. Two-chamber heart (atrium and ventricle) appeared among mollusks. Vertebrates have a multi-chamber heart and a closed circulation with capillaries. Their heart has two chambers in fishes, three chambers (two atria and one ventricle) in amphibians and reptiles, and four chambers in birds and mammals. The ventricle of reptiles is partially divided in two cavities by an interventricular septum, leaving only a communication of variable size leading to a variable shunt. Blood pressure increases progressively from 15 mmHg (worms) to 170/70 mmHg (birds) according to the increase in metabolic rate. When systemic pressure exceeds 50 mmHg, a lower pressure system appears for the circulation through gills or lungs in order to improve gas exchange. A four-chamber heart allows a complete separation of systemic and pulmonary circuits. This review describes the circulatory pumping systems used in the different classes of animals, their advantages and failures, and the way they have been modified with evolution. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  17. Mechanical ventilation and thoracic artificial lung assistance during mechanical circulatory support with PUCA pump: in silico study.

    PubMed

    De Lazzari, Claudio; Genuini, Igino; Quatember, Bernhard; Fedele, Francesco

    2014-02-01

    Patients assisted with left ventricular assist device (LVAD) may require prolonged mechanical ventilatory assistance secondary to postoperative respiratory failure. The goal of this work is the study of the interdependent effects LVAD like pulsatile catheter (PUCA) pump and mechanical ventilatory support or thoracic artificial lung (TAL), by the hemodynamic point of view, using a numerical simulator of the human cardiovascular system. In the simulator, different circulatory sections are described using lumped parameter models. Lumped parameter models have been designed to describe the hydrodynamic behavior of both PUCA pump and thoracic artificial lung. Ventricular behavior atrial and septum functions were reproduced using variable elastance model. Starting from simulated pathological conditions we studied the effects produced on some hemodynamic variables by simultaneous PUCA pump, thoracic artificial lung or mechanical ventilation assistance. Thoracic artificial lung was applied in parallel or in hybrid mode. The effects of mechanical ventilation have been simulated by changing mean intrathoracic pressure value from -4 mmHg to +5 mmHg. The hemodynamic variables observed during the simulations, in different assisted conditions, were: left and right ventricular end systolic (diastolic) volume, systolic/diastolic aortic pressure, mean pulmonary arterial pressure, left and right mean atrial pressure, mean systemic venous pressure and the total blood flow. Results show that the application of PUCA (without mechanical ventilatory assistance) increases the total blood flow, reduces the left ventricular end systolic volume and increases the diastolic aortic pressure. Parallel TAL assistance increases the right ventricular end diastolic (systolic) volume reduction both when PUCA is switched "ON" and both when PUCA is switched "OFF". By switching "OFF" the PUCA pump, it seems that parallel thoracic artificial lung assistance produces a greater cardiac output (respect to

  18. A Fully Magnetically Levitated Circulatory Pump for Advanced Heart Failure.

    PubMed

    Mehra, Mandeep R; Naka, Yoshifumi; Uriel, Nir; Goldstein, Daniel J; Cleveland, Joseph C; Colombo, Paolo C; Walsh, Mary N; Milano, Carmelo A; Patel, Chetan B; Jorde, Ulrich P; Pagani, Francis D; Aaronson, Keith D; Dean, David A; McCants, Kelly; Itoh, Akinobu; Ewald, Gregory A; Horstmanshof, Douglas; Long, James W; Salerno, Christopher

    2017-02-02

    Continuous-flow left ventricular assist systems increase the rate of survival among patients with advanced heart failure but are associated with the development of pump thrombosis. We investigated the effects of a new magnetically levitated centrifugal continuous-flow pump that was engineered to avert thrombosis. We randomly assigned patients with advanced heart failure to receive either the new centrifugal continuous-flow pump or a commercially available axial continuous-flow pump. Patients could be enrolled irrespective of the intended goal of pump support (bridge to transplantation or destination therapy). The primary end point was a composite of survival free of disabling stroke (with disabling stroke indicated by a modified Rankin score >3; scores range from 0 to 6, with higher scores indicating more severe disability) or survival free of reoperation to replace or remove the device at 6 months after implantation. The trial was powered for noninferiority testing of the primary end point (noninferiority margin, -10 percentage points). Of 294 patients, 152 were assigned to the centrifugal-flow pump group and 142 to the axial-flow pump group. In the intention-to-treat population, the primary end point occurred in 131 patients (86.2%) in the centrifugal-flow pump group and in 109 (76.8%) in the axial-flow pump group (absolute difference, 9.4 percentage points; 95% lower confidence boundary, -2.1 [P<0.001 for noninferiority]; hazard ratio, 0.55; 95% confidence interval [CI], 0.32 to 0.95 [two-tailed P=0.04 for superiority]). There were no significant between-group differences in the rates of death or disabling stroke, but reoperation for pump malfunction was less frequent in the centrifugal-flow pump group than in the axial-flow pump group (1 [0.7%] vs. 11 [7.7%]; hazard ratio, 0.08; 95% CI, 0.01 to 0.60; P=0.002). Suspected or confirmed pump thrombosis occurred in no patients in the centrifugal-flow pump group and in 14 patients (10.1%) in the axial-flow pump group

  19. Circular pump support of blood circulation in the human body

    NASA Astrophysics Data System (ADS)

    Medvedev, A. E.; Fomin, V. M.; Prikhodko, Yu. M.; Cherniavskiy, A. M.; Fomichev, V. P.; Fomichev, A. V.; Chekhov, V. P.; Ruzmatov, T. M.

    2016-10-01

    The need of circulatory support systems in the treatment of chronic heart failure is increasing constantly, as 20% of patients in the waiting list die every year. Despite the great need for mechanical heart support systems, using of available systems is limited by the expensiveness. In addition, there is no one system that is 100% responsible to all medical and technical requirements, and would be completely safe for patient. Therefore, further research in the field of circu-latory support systems, considering health and technical requirements is relevant. One of the new directions in the study are disc pumps of viscous friction for liquid transporting, based on the Tesla pump principle. The operation principle of pumps based on the phenomenon of the boundary layer which is formed on the disk rotating in a fluid. There are experimental studies results of models with different variants of the rotor suspension, the various forms and the number of disks, forms the pump housing. However, none of the above samples was not brought to clinical trials. Furthermore, despite the promise of this model is still used today in some circulatory support systems are no similar type pump. Published data provide a basis for further development and testing of the pump model and allow to hope for leveling a number of significant shortcomings of modern left ventricular bypass systems.

  20. Hybrid model analysis of intra-aortic balloon pump performance as a function of ventricular and circulatory parameters.

    PubMed

    Ferrari, Gianfranco; Khir, Ashraf W; Fresiello, Libera; Di Molfetta, Arianna; Kozarski, Maciej

    2011-09-01

    We investigated the effects of the intra-aortic balloon pump (IABP) on endocardial viability ratio (EVR), cardiac output (CO), end-systolic (V(es)) and end-diastolic (V(ed)) ventricular volumes, total coronary blood flow (TCBF), and ventricular energetics (external work [EW], pressure-volume area [PVA]) under different ventricular (E(max) and diastolic stiffness) and circulatory (arterial compliance) parameters. We derived a hybrid model from a computational model, which is based on merging computational and hydraulic submodels. The lumped parameter computational submodel consists of left and right hearts and systemic, pulmonary, and coronary circulations. The hydraulic submodel includes part of the systemic arterial circulation, essentially a silicone rubber tube representing the aorta, which contains a 40-mL IAB. EVR, CO, V(es), and V(ed), TCBF and ventricular energetics (EW, PVA) were analyzed against the ranges of left ventricular E(max) (0.3-0.5-1 mm Hg/cm(3)) and diastolic stiffness V(stiffness) (≈0.08 and ≈0.3 mm Hg/cm(3), obtained by changing diastolic stiffness constant) and systemic arterial compliance (1.8-2.5 cm(3)/mm Hg). All experiments were performed comparing the selected variables before and during IABP assistance. Increasing E(maxl) from 0.5 to 2 mm Hg/cm(3) resulted in IABP assistance producing lower percentage changes in the selected variables. The changes in ventricular diastolic stiffness strongly influence both absolute value of EVR and its variations during IABP (71 and 65% for lower and higher arterial compliance, respectively). V(ed) and V(es) changes are rather small but higher for lower E(max) and higher V(stiffness). Lower E(max) and higher V(stiffness) resulted in higher TCBF and CO during IABP assistance (∼35 and 10%, respectively). The use of this hybrid model allows for testing real devices in realistic, stable, and repeatable circulatory conditions. Specifically, the presented results show that IABP performance is dependent

  1. Development of mechanical circulatory support devices in China.

    PubMed

    Wang, Wei; Zhu, De-Ming; Ding, Wen-Xiang

    2009-11-01

    Myocardial dysfunction leading to low cardiac output syndrome is a common clinical pathophysiological state. Currently, the use of mechanical circulatory support (MCS) is an essential aspect of the treatment of patients with cardiac failure. Several groups in China are engaged in the design and development of MCS devices. These devices can be classified as pulsatile, rotary, and total artificial heart (TAH). There are two types of pulsatile pump, which are driven by air (pneumatic). One of these pumps, the Luo-Ye pump, has been used clinically for short-term support since 1998. The other is a push-plate left ventricular device, which has a variable rate mode. Various rotary devices are classified into axial and centrifugal pumps, depending on the impeller geometry. Most rotary pumps are based on the maglev principle, and some types have been used clinically. Others are still being studied in the laboratory or in animal experiments. Furthermore, certain types of total implantable pump, such as the UJS-III axial pump and the UJS-IV aortic valvo-pump, have been developed. Only one type of TAH has been developed in China. The main constituents of this artificial heart are two axial pumps, two reservoir tanks mimicking the right and left atria, flow meters, two pressure gauges, and a resistance adaptor. Although the development of mechanical assist devices in China is still in a nascent stage, a number of different types of MCS devices are currently being studied.

  2. Options for temporary mechanical circulatory support

    PubMed Central

    Saffarzadeh, Areo

    2015-01-01

    Temporary mechanical circulatory support (MCS) refers to a group of devices generally used for less than 30 days to maintain adequate organ perfusion by compensating for a failure of the pumping mechanism of the heart. The increased availability and rapid adoption of new temporary MCS strategies necessitate physicians to become familiar with devices placed both percutaneously and via median sternotomy. This review will examine the different options for commonly used temporary MCS devices including intra-aortic balloon pumps (IABPs), veno-arterial-extracorporeal membrane oxygenation (VA-ECMO), TandemHeart® (CardiacAssist, Pittsburg, PA, USA) Impella® and BVS 5000® (both Abiomed Inc., Danvers, MA, USA), CentriMag® and Thoratec percutaneous ventricular assist device (pVAD)® (both Thoratec Corporation, Pleasanton, CA, USA). A specific emphasis will be made to describe relevant mechanisms of action, standard placement strategies, hemodynamic effects, relevant contraindications and complications, and important daily management considerations. PMID:26793330

  3. An implantable centrifugal blood pump for long term circulatory support.

    PubMed

    Yamazaki, K; Litwak, P; Kormos, R L; Mori, T; Tagusari, O; Antaki, J F; Kameneva, M; Watach, M; Gordon, L; Umezu, M; Tomioka, J; Koyanagi, H; Griffith, B P

    1997-01-01

    A compact centrifugal blood pump was developed as an implantable left ventricular assist system. The impeller diameter is 40 mm and the pump dimensions are 55 x 64 mm. This first prototype was fabricated from titanium alloy, resulting in a pump weight of 400 g including a brushless DC motor. Weight of the second prototype pump was reduced to 280 g. The entire blood contacting surface is coated with diamond like carbon to improve blood compatibility. Flow rates of over 7 L/min against 100 mmHg pressure at 2,500 rpm with 9 W total power consumption have been measured. A newly designed mechanical seal with a recirculating purge system ("Cool-Seal") is used as a shaft seal. In this seal system, seal temperature is kept under 40 degrees C to prevent heat denaturation of blood proteins. Purge fluid also cools the pump motor coil and journal bearing. The purge fluid is continuously purified and sterilized by an ultrafiltration filter incorporated into the paracorporeal drive console. In vitro experiments with bovine blood demonstrated an acceptably low hemolysis rate (normalized index of hemolysis = 0.005 +/- 0.002 g/100 L). In vivo experiments are currently ongoing using calves. Via left thoracotomy, left ventricular apex-descending aorta bypass was performed utilizing a PTFE (Polytetrafluoroethylene) vascular graft, with the pump placed in the left thoracic cavity. In two in vivo experiments, pump flow rate was maintained at 5-8 L/min, and pump power consumption remained stable at 9-10 W. All plasma free hemoglobin levels were measured at < 15 mg/dl. The seal system has demonstrated good seal capability with negligible purge fluid consumption (< 0.5 ml/ day). Both animals remain under observation after 162 and 91 days of continuous pump function.

  4. Development of a hybrid (numerical-hydraulic) circulatory model: prototype testing and its response to IABP assistance.

    PubMed

    Ferrari, G; Kozarski, M; De Lazzari, C; Górczyńska, K; Tosti, G; Darowski, M

    2005-07-01

    Merging numerical and physical models of the circulation makes it possible to develop a new class of circulatory models defined as hybrid. This solution reduces the costs, enhances the flexibility and opens the way to many applications ranging from research to education and heart assist devices testing. In the prototype described in this paper, a hydraulic model of systemic arterial tree is connected to a lumped parameters numerical model including pulmonary circulation and the remaining parts of systemic circulation. The hydraulic model consists of a characteristic resistance, of a silicon rubber tube to allow the insertion of an Intra-Aortic Balloon Pump (IABP) and of a lumped parameters compliance. Two electro-hydraulic interfaces, realized by means of gear pumps driven by DC motors, connect the numerical section with both terminals of the hydraulic section. The lumped parameters numerical model and the control system (including analog to digital and digital to analog converters)are developed in LabVIEW environment. The behavior of the model is analyzed by means of the ventricular pressure-volume loops and the time courses of arterial and ventricular pressures and flows in different circulatory conditions. A simulated pathological condition was set to test the IABP and verify the response of the system to this type of mechanical circulatory assistance. The results show that the model can represent hemodynamic relationships in different ventricular and circulatory conditions and is able to react to the IABP assistance.

  5. Fluid Dynamics in Rotary Piston Blood Pumps.

    PubMed

    Wappenschmidt, Johannes; Sonntag, Simon J; Buesen, Martin; Gross-Hardt, Sascha; Kaufmann, Tim; Schmitz-Rode, Thomas; Autschbach, Ruediger; Goetzenich, Andreas

    2017-03-01

    Mechanical circulatory support can maintain a sufficient blood circulation if the native heart is failing. The first implantable devices were displacement pumps with membranes. They were able to provide a sufficient blood flow, yet, were limited because of size and low durability. Rotary pumps have resolved these technical drawbacks, enabled a growing number of mechanical circulatory support therapy and a safer application. However, clinical complications like gastrointestinal bleeding, aortic insufficiency, thromboembolic complications, and impaired renal function are observed with their application. This is traced back to their working principle with attenuated or non-pulsatile flow and high shear stress. Rotary piston pumps potentially merge the benefits of available pump types and seem to avoid their complications. However, a profound assessment and their development requires the knowledge of the flow characteristics. This study aimed at their investigation. A functional model was manufactured and investigated with particle image velocimetry. Furthermore, a fluid-structure interaction computational simulation was established to extend the laboratory capabilities. The numerical results precisely converged with the laboratory measurements. Thus, the in silico model enabled the investigation of relevant areas like gap flows that were hardly feasible with laboratory means. Moreover, an economic method for the investigation of design variations was established.

  6. A multiple disk centrifugal pump as a blood flow device.

    PubMed

    Miller, G E; Etter, B D; Dorsi, J M

    1990-02-01

    A multiple disk, shear force, valveless centrifugal pump was studied to determine its suitability as a blood flow device. A pulsatile version of the Tesla viscous flow turbine was designed by modifying the original steady flow pump concept to produce physiological pressures and flows with the aid of controlling circuitry. Pressures and flows from this pump were compared to a Harvard Apparatus pulsatile piston pump. Both pumps were connected to an artificial circulatory system. Frequency and systolic duration were varied over a range of physiological conditions for both pumps. The results indicated that the Tesla pump, operating in a pulsatile mode, is capable of producing physiologic pressures and flows similar to the Harvard pump and other pulsatile blood pumps.

  7. Small Bowel Bacterial Overgrowth Associated with Persistence of Abdominal Symptoms in Children Treated with a Proton Pump Inhibitor.

    PubMed

    Sieczkowska, Agnieszka; Landowski, Piotr; Zagozdzon, Pawel; Kaminska, Barbara; Lifschitz, Carlos

    2015-05-01

    Small bowel bacterial overgrowth (SBBO) was diagnosed in 22.5% of 40 children treated for 3 months with a proton pump inhibitor (PPI). Compared with those without SBBO, children with SBBO had higher frequency of abdominal pain, bloating, eructation, and flatulence. Patients with gastrointestinal symptoms after PPI treatment should be evaluated for SBBO rather than empirically prolonging PPI therapy. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Left heart bypass support with the Rotaflow Centrifugal Pump® as a bridge to decision and recovery in an adult.

    PubMed

    Kashiwa, Koichi; Nishimura, Takashi; Saito, Aya; Kubo, Hitoshi; Fukaya, Aoi; Tamai, Hisayoshi; Yambe, Tomoyuki; Kyo, Shunei; Ono, Minoru

    2012-06-01

    Since left heart bypass or biventricular circulatory assist with an extracorporeal centrifugal pump as a bridge to decision or recovery sometimes requires long-time support, the long-term durability of extracorporeal centrifugal pumps is crucial. The Rotaflow Centrifugal Pump(®) (MAQUET Cardiopulmonary AG, Hirrlingen, Germany) is one of the centrifugal pumps available for long-term use in Japan. However, there have been few reports of left heart bypass or biventricular circulatory support over the mid-term. This is a case report of left heart bypass support with the Rotaflow Centrifugal Pump(®) as a bridge to decision and recovery for an adult patient who could not be weaned from cardiopulmonary bypass and percutaneous cardiopulmonary support after cardiac surgery. We could confirm that the patient's consciousness level was normal; however, the patient could not be weaned from the left heart bypass support lasting 1 month. Therefore, the circulatory assist device was switched to the extracorporeal Nipro ventricular assist device (VAD). This time, left heart bypass support could be maintained for 30 days using a single Rotaflow Centrifugal Pump(®). There were no signs of hemolysis during left heart bypass support. The Rotaflow Centrifugal Pump(®) itself may be used as a device for a bridge to decision or recovery before using a VAD in cardiogenic shock patients.

  9. Mechanical Circulatory Support of the Critically Ill Child Awaiting Heart Transplantation

    PubMed Central

    Gazit, Avihu Z; Gandhi, Sanjiv K; C Canter, Charles

    2010-01-01

    The majority of children awaiting heart transplantation require inotropic support, mechanical ventilation, and/or extracorporeal membrane oxygenation (ECMO) support. Unfortunately, due to the limited pool of organs, many of these children do not survive to transplant. Mechanical circulatory support of the failing heart in pediatrics is a new and rapidly developing field world-wide. It is utilized in children with acute congestive heart failure associated with congenital heart disease, cardiomyopathy, and myocarditis, both as a bridge to transplantation and as a bridge to myocardial recovery. The current arsenal of mechanical assist devices available for children is limited to ECMO, intra-aortic balloon counterpulsation, centrifugal pump ventricular assist devices, the DeBakey ventricular assist device Child; the Thoratec ventricular assist device; and the Berlin Heart. In the spring of 2004, five contracts were awarded by the National Heart, Lung and Blood Institute to support preclinical development for a range of pediatric ventricular assist devices and similar circulatory support systems. The support of early development efforts provided by this program is expected to yield several devices that will be ready for clinical trials within the next few years. Our work reviews the current international experience with mechanical circulatory support in children and summarizes our own experience since 2005 with the Berlin Heart, comparing the indications for use, length of support, and outcome between these modalities. PMID:21286278

  10. Design and evaluation of a single-pivot supported centrifugal blood pump.

    PubMed

    Yoshino, M; Uemura, M; Takahashi, K; Watanabe, N; Hoshi, H; Ohuchi, K; Nakamura, M; Fujita, H; Sakamoto, T; Takatani, S

    2001-09-01

    In order to develop a centrifugal blood pump that meets the requirements of a long-term, implantable circulatory support device, in this study a single-pivot bearing supported centrifugal blood pump was designed to evaluate its basic performance. The single-pivot structure consisted of a ceramic ball male pivot mounted on the bottom surface of the impeller and a polyethylene female pivot incorporated in the bottom pump casing. The follower magnet mounted inside the impeller was magnetically coupled to the driver magnet mounted on the shaft of the direct current brushless motor. As the motor rotated, the impeller rotated supported entirely by a single-pivot bearing system. The static pump performance obtained in the mock circulatory loop revealed an acceptable performance as a left ventricular assist device in terms of flow and head pressure. The pump flow of 5 L/min against the head pressure of 100 mm Hg was obtained at rotational speeds of 2,000 to 2,200 rpm. The maximum pump flow was 9 L/min with 2,200 rpm. The maximum electrical-to-hydraulic power conversion efficiency was around 14% at pump flows of 4 to 5 L/min. The stability of the impeller was demonstrated at the pump rpm higher than 1,400 with a single-pivot bearing without an additional support at its top. The single-pivot supported centrifugal pump can provide adequate flow and pressure as a ventricular assist device, but its mechanical stability and hemolytic as well as thrombotic performances must be tested prior to clinical use.

  11. A computer model of the pediatric circulatory system for testing pediatric assist devices.

    PubMed

    Giridharan, Guruprasad A; Koenig, Steven C; Mitchell, Michael; Gartner, Mark; Pantalos, George M

    2007-01-01

    Lumped parameter computer models of the pediatric circulatory systems for 1- and 4-year-olds were developed to predict hemodynamic responses to mechanical circulatory support devices. Model parameters, including resistance, compliance and volume, were adjusted to match hemodynamic pressure and flow waveforms, pressure-volume loops, percent systole, and heart rate of pediatric patients (n = 6) with normal ventricles. Left ventricular failure was modeled by adjusting the time-varying compliance curve of the left heart to produce aortic pressures and cardiac outputs consistent with those observed clinically. Models of pediatric continuous flow (CF) and pulsatile flow (PF) ventricular assist devices (VAD) and intraaortic balloon pump (IABP) were developed and integrated into the heart failure pediatric circulatory system models. Computer simulations were conducted to predict acute hemodynamic responses to PF and CF VAD operating at 50%, 75% and 100% support and 2.5 and 5 ml IABP operating at 1:1 and 1:2 support modes. The computer model of the pediatric circulation matched the human pediatric hemodynamic waveform morphology to within 90% and cardiac function parameters with 95% accuracy. The computer model predicted PF VAD and IABP restore aortic pressure pulsatility and variation in end-systolic and end-diastolic volume, but diminish with increasing CF VAD support.

  12. Feasibility of a tiny Gyro centrifugal pump as an implantable ventricular assist device.

    PubMed

    Yoshikawa, M; Nakata, K; Ohtsuka, G; Takano, T; Glueck, J; Fujisawa, A; Makinouchi, K; Yokokawa, M; Nosé, Y

    1999-08-01

    The Gyro pumps were developed for long-term circulatory support. The first generation Gyro pump (C1E3) achieved 1 month paracorporeal circulatory support in chronic animal experiments; the second generation (PI702) implantable ventricular assist device (VAD) was successful for over 6 months. The objective of the next generation Gyro pump is for use as a long-term totally implantable VAD and for pediatric circulatory support. This tiny Gyro pump (KP101) was fabricated with the same design concept as the other Gyro pumps. The possibility of an implantable VAD was determined after performance and hemolysis test results were compared to those of the other Gyro pumps. The pump housing and impeller were fabricated from polycarbonate with an impeller diameter of 35 mm. The diameter and height of the pump housings are 52.3 mm and 29.9 mm, respectively. At this time, a DC brushless motor drives the KP101, which is the same as that for the C1E3. The pump performance was measured in 37% glycerin water at 37 degrees C. Hemolysis tests were performed utilizing a compact mock loop filled with fresh bovine blood in a left ventricular assist device (LVAD) condition at 37 degrees C. The KP101 achieved the LVAD conditions of 5 L/min and 100 mm Hg at 2,900 rpm; generated 10 L/min against 100 mm Hg at 3,200 rpm; 3 L/min against 90 mm Hg at 2,600 rpm; and 2 L/min against 80 mm Hg at 2,400 rpm. In addition, the pump efficiency during this experiment was 12.5%. The other Gyro pumps. that is, the C1E3, PI601, and PI701, in an LVAD condition require 1,600, 2,000, and 2,000 rpm, respectively. The KP101 produced a normalized index of hemolysis (NIH) value of 0.005 g/100 L. With regard to the NIH, the other Gyro pumps, namely the C1E3, PI601, and PI701 demonstrated 0.0007, 0.0028, and 0.004 g/100 L, respectively. The KP101 produced an acceptable pressure flow curve for a VAD. The NIH value was higher than that of other Gyro pumps, but is in an acceptable range.

  13. Mathematical modelling of flow in disc friction LVAD pump

    NASA Astrophysics Data System (ADS)

    Medvedev, A. E.; Fomin, V. M.; Prikhodko, Yu. M.; Cherniavskiy, A. M.; Fomichev, V. P.; Fomichev, A. V.; Chekhov, V. P.; Ruzmatov, T. M.

    2017-10-01

    The need for blood circulation support systems in the treatment of chronic heart failure is constantly increasing as 20% of patients on the waiting list die every year. Despite the great need for mechanical heart support systems the use of available systems is limited by the high cost. Therefore, further research in the field of circulatory support systems is appropriate taking into account medical and technical requirements. One of the new research areas is viscous friction disk pumps for transporting liquids based on the Tesla pump principle. The experimental model of LVAD disk pump is developed. Analytical dependencies are obtained to optimize the hydraulic parameters of the pump. On their basis, the experimental model of LVAD disk pump was designed and created. The results of analytical and experimental studies of such a pump are presented.

  14. Totally normothermic aortic arch replacement without circulatory arrest.

    PubMed

    Touati, Gilles D; Marticho, Paul; Farag, Moataz; Carmi, Doron; Szymanski, Catherine; Barry, Misbaou; Trojette, Faouzi; Caus, Thierry

    2007-08-01

    Various techniques have been proposed for cerebral protection during the surgical treatment of complex aortic disease. The authors propose a revisited strategy of normothermic replacement of the aortic arch to avoid limitations and complications of profound hypothermic circulatory arrest. From April 2000 to May 2006, 19 patients with an aneurysm of the aortic arch and 10 patients with an acute (7) or a chronic (3) aortic dissection underwent a totally normothermic, complete replacement of the aortic arch using three pumps: One pump ensured antegrade cerebral perfusion, at a flow rate adapted to obtain a pressure of 70 mmHg in the right radial artery, and required a selective cannulation of the supra-aortic vessels. A second pump ensured body perfusion at a flow rate adapted to obtain a pressure of 55 mmHg in the left femoral artery and was situated between the right femoral artery and the right atrium. A special balloon aortic occlusion catheter was placed in the descending thoracic aorta. A third pump ensured intermittent normothermic myocardial perfusion via the coronary venous sinus. The arch reconstruction was performed with no time limit. There were two operative, in-hospital (6.8%) mortalities. All others patients were rapidly extubated, except one, with no neurological sequelae, and postoperative course was uneventful, without coagulopathy or hepato-renal impairment. In the light of these results, a normothermic procedure is possible for arch surgery and may ensure a more physiological autoregulation of cerebral blood flow while maintaining body perfusion without high vascular resistances.

  15. Mathematical circulatory system model

    NASA Technical Reports Server (NTRS)

    Lakin, William D. (Inventor); Stevens, Scott A. (Inventor)

    2010-01-01

    A system and method of modeling a circulatory system including a regulatory mechanism parameter. In one embodiment, a regulatory mechanism parameter in a lumped parameter model is represented as a logistic function. In another embodiment, the circulatory system model includes a compliant vessel, the model having a parameter representing a change in pressure due to contraction of smooth muscles of a wall of the vessel.

  16. 38 CFR 4.62 - Circulatory disturbances.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2010-07-01 2010-07-01 false Circulatory disturbances. 4.62 Section 4.62 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS SCHEDULE FOR RATING DISABILITIES Disability Ratings The Musculoskeletal System § 4.62 Circulatory disturbances...

  17. 38 CFR 4.62 - Circulatory disturbances.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2014-07-01 2014-07-01 false Circulatory disturbances. 4.62 Section 4.62 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS SCHEDULE FOR RATING DISABILITIES Disability Ratings The Musculoskeletal System § 4.62 Circulatory disturbances...

  18. 38 CFR 4.62 - Circulatory disturbances.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2013-07-01 2013-07-01 false Circulatory disturbances. 4.62 Section 4.62 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS SCHEDULE FOR RATING DISABILITIES Disability Ratings The Musculoskeletal System § 4.62 Circulatory disturbances...

  19. 38 CFR 4.62 - Circulatory disturbances.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2011-07-01 2011-07-01 false Circulatory disturbances. 4.62 Section 4.62 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS SCHEDULE FOR RATING DISABILITIES Disability Ratings The Musculoskeletal System § 4.62 Circulatory disturbances...

  20. 38 CFR 4.62 - Circulatory disturbances.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2012-07-01 2012-07-01 false Circulatory disturbances. 4.62 Section 4.62 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS SCHEDULE FOR RATING DISABILITIES Disability Ratings The Musculoskeletal System § 4.62 Circulatory disturbances...

  1. Development of a centrifugal pump with improved antithrombogenicity and hemolytic property for chronic circulatory support.

    PubMed

    Taenaka, Y; Wakisaka, Y; Masuzawa, T; Tatsumi, E; Toda, K; Miyazaki, K; Eya, K; Baba, Y; Nakatani, T; Ohno, T; Nishimura, T; Takano, H

    1996-06-01

    A centrifugal pump with a unique structure has been developed for chronic support. The pump is driven by a magnetic coupling and has no rotating shaft, no seal around the rotating part, and a balancing hole at the center of the impeller and the thrust bearing. The pump was improved in stepwise fashion to realize good antithrombogenicity and low hemolysis. The first pump, the National Cardiovascular Center (NCVC)-0, had an impeller with 4 rectangular and curved vanes; 6 triangularly shaped curved vanes were employed in the second model, the NCVC-1, to reduce trauma to the blood. In the third design, the NCVC-2, the central hole was enlarged, and the thrust bearing shoulder was rounded so that blood washing was enhanced around the impeller; stream lines also were smoothed for improved antithrombogenicity. The hemolytic property of the device was evaluated in vitro with heparinized fresh goat blood; hemolysis indexes of the NCVC-0, -1, and -2 were 0.05, 0.01, and 0.006 g per 100 L, respectively. Antithrombogenicity of the pumps was examined in animal experiments as a left heart bypass device in goals weighing 52-75 kg. Six NCVC-0 pumps were driven for 14 to 33 (22.0 +/- 7.6) days in goats receiving the antiplatelet drug cilostazol orally. Four NCVC-1 pumps ran for 1 to 80 (28.5 +/- 30.6) days with the same drug regimen in 2 cases and with no anticoagulation therapy in 2 cases. After 3 preliminary 1-week tests of NCVC-2 pumps in animals, the pump was installed in 3 goats; 2 pumps were still running on the 182nd and 58th pumping day. Intracorporeal implantation also was attempted successfully. The results indicate that this pump has promising features for chronic support although longer term and additional evaluations are necessary.

  2. Pediatric Donation After Circulatory Determination of Death: A Scoping Review.

    PubMed

    Weiss, Matthew J; Hornby, Laura; Witteman, William; Shemie, Sam D

    2016-03-01

    Although pediatric donation after circulatory determination of death is increasing in frequency, there are no national or international donation after circulatory determination of death guidelines specific to pediatrics. This scoping review was performed to map the pediatric donation after circulatory determination of death literature, identify pediatric donation after circulatory determination of death knowledge gaps, and inform the development of national or regional pediatric donation after circulatory determination of death guidelines. Terms related to pediatric donation after circulatory determination of death were searched in Embase and MEDLINE, as well as the non-MEDLINE sources in PubMed from 1980 to May 2014. Seven thousand five hundred ninety-seven references were discovered and 85 retained for analysis. All references addressing pediatric donation after circulatory determination of death were considered. Exclusion criteria were articles that did not address pediatric patients, animal or laboratory studies, surgical techniques, and local pediatric donation after circulatory determination of death protocols. Narrative reviews and opinion articles were the most frequently discovered reference (25/85) and the few discovered studies were observational or qualitative and almost exclusively retrospective. Retained references were divided into themes and analyzed using qualitative methodology. The main discovered themes were 1) studies estimating the number of potential pediatric donation after circulatory determination of death donors and their impact on donation; 2) ethical issues in pediatric donation after circulatory determination of death; 3) physiology of the dying process after withdrawal of life-sustaining therapy; 4) cardiac pediatric donation after circulatory determination of death; and 5) neonatal pediatric donation after circulatory determination of death. Donor estimates suggest that pediatric donation after circulatory determination of death will

  3. Development of a Centrifugal Pump with Improved Antithrombogenicity and Hemolytic Property for Chronic Circulatory Support.

    PubMed

    Taenaka, Yoshiyuki; Wakisaka, Yoshinari; Masuzawa, Toru; Tatsumi, Eisuke; Toda, Koichi; Miyazaki, Koji; Eya, Kazuhiro; Baba, Yuzo; Nakatani, Takeshi; Ohno, Takashi; Nishimura, Takashi; Takano, Hisateru

    1996-05-01

    A centrifugal pump with a unique structure has been developed for chronic support. The pump is driven by a magnetic coupling and has no rotating shaft, no seal around the rotating part, and a balancing hole at the center of the impeller and the thrust bearing. The pump was improved in stepwise fashion to realize good antithrombogenicity and low hemolysis. The first pump, the National Cardiovascular Center (NCVC)-O, had an impeller with 4 rectangular and curved vanes; 6 triangularly shaped curved vanes were employed in the second model, the NCVC-1, to reduce trauma to the blood. In the third design, the NCVC-2, the central hole was enlarged, and the thrust bearing shoulder was rounded so that blood washing was enhanced around the impeller; stream lines also were smoothed for improved antithrombogenicity. The hemolytic property of the device was evaluated in vitro with heparinized fresh goat blood; hemolysis indexes of the NCVC-0, -1, and -2 were 0.05, 0.01, and 0.006 g per 100 L, respectively. Antithrombogenicity of the pumps was examined in animal experiments as a left heart bypass device in goats weighing 52-75 kg. Six NCVC-0 pumps were driven for 14 to 33 (22.0 ± 7.6) days in goats receiving the antiplatelet drug cilostazol orally. Four NCVC-I pumps ran for 1 to 80 (28.5 ± 30.6) days with the same drug regimen in 2 cases and with no anticoagulation therapy in 2 cases. After 3 preliminary 1-week tests of NCVC-2 pumps in animals, the pump was installed in 3 goats; 2 pumps were still running on the 182nd and 58th pumping day. Intracorporeal implantation also was attempted successfully. The results indicate that this pump has promising features for chronic support although longer term and additional evaluations are necessary. © 1996 International Society for Artificial Organs.

  4. Fetal circulatory responses to oxygen lack.

    PubMed

    Jensen, A; Berger, R

    1991-10-01

    The knowledge on fetal and neonatal circulatory physiology accumulated by basic scientists and clinicians over the years has contributed considerably to the recent decline of perinatal morbidity and mortality. This review will summarize the peculiarities of the fetal circulation, the distribution of organ blood flow during normoxemia, and that during oxygen lack caused by various experimental perturbations. Furthermore, the relation between oxygen delivery and tissue metabolism during oxygen lack as well as evidence to support a new concept will be presented along with the principal cardiovascular mechanisms involved. Finally, blood flow and oxygen delivery to the principal fetal organs will be examined and discussed in relation to organ function. The fetal circulatory response to hypoxemia and asphyxia is a centralization of blood flow in favour of the brain, heart, and adrenals and at the expense of almost all peripheral organs, particularly of the lungs, carcass, skin and scalp. This response is qualitatively similar but quantitatively different under various experimental conditions. However, at the nadir of severe acute asphyxia the circulatory centralization cannot be maintained. Then there is circulatory decentralization, and the fetus will experience severe brain damage if not expire unless immediate resuscitation occurs. Future work in this field will have to concentrate on the important questions, what factors determine this collapse of circulatory compensating mechanisms in the fetus, how does it relate to neuronal damage, and how can the fetal brain be pharmacologically protected against the adverse effects of asphyxia.

  5. LONG-TERM MECHANICAL CIRCULATORY SUPPORT (DESTINATION THERAPY): ON TRACK TO COMPETE WITH HEART TRANSPLANTATIO?

    PubMed Central

    Kirklin, James K.; Naftel, David C.; Pagani, Francis D.; Kormos, Robert L.; Stevenson, Lynne; Miller, Marissa; Young, James B.

    2012-01-01

    Objective(s) Average two-year survival following cardiac transplantation is approximately 80%. The evolution and subsequent approval of larger pulsatile and, more recently, continuous flow mechanical circulatory support (MCS) technology for destination therapy (DT) offers the potential for triage of some patients awaiting cardiac transplantation to DT. Methods The National Heart, Lung and Blood Institute Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) is a national multi-institutional study of chronic mechanical circulatory support. Between June 2006 and December 2011, 127 pulsatile and 1160 continuous flow pumps (24% of total primary LVADs) carried an initial strategy of DT therapy. Results By multivariable analysis, risk factors (p<0.05) for mortality following DT included older age, larger body mass index, history of cancer, history of cardiac surgery, INTERMACS level I (cardiogenic shock), dialysis, increased BUN, use of a pulsatile flow device and use of a RVAD. Among continuous flow LVAD patients who were not in cardiogenic shock, a particularly favorable survival was associated with no cancer, patients not in cardiogenic shock, and BUN < 50, resulting in one and two year survival of 88 and 80%. Conclusions 1) Evolution from pulsatile to continuous flow technology has dramatically improved one and two year survival; 2) Destination Therapy is not appropriate for patients with rapid hemodynamic deterioration; or severe right ventricular failure 4) Important subsets of continuous flow DT patients now enjoy survival which is competitive with heart transplantation out to about two years. PMID:22795459

  6. Rotacor: a new rotary blood pump.

    PubMed

    Margreiter, R; Schwab, W; Klima, G; Koller, J; Baum, M; Dietrich, H; Hager, J; Königsrainer, A

    1990-01-01

    A new rotary blood pump was tested in calves for 6 hr. The pump consists of a rigid housing with a trochoidal internal surface, an inlet and outlet, and two lateral walls. A two-corner piston rotates on an eccentric shaft in a trochoidal path, thus creating a gap seal. The pump is driven by a water-cooled DC motor. For right ventricular assist, a cannula was inserted into the right ventricle through the right atrium, and into the left ventricle for left ventricular assist. From a total of 10 experiments, two left ventricular assists, two right ventricular assists, and three biventricular assists were evaluated. The pump produced a pulsatile flow of 3 L at 70 rpm. Energy requirements were 2.19 watts for left, 2.06 for right, and 7.26 for biventricular assists. Plasma hemoglobin remained as low as 10 mg/dl during monoventricular, and increased during biventricular assists to 20 mg/dl after 3 hr, when it started to chop again; after 6 hr it was 16 mg/dl. From these preliminary results it is concluded that this new type of blood pump may be suitable as a circulatory assist device.

  7. Contemporary Risk Factors and Outcomes of Transfusion-Associated Circulatory Overload.

    PubMed

    Roubinian, Nareg H; Hendrickson, Jeanne E; Triulzi, Darrell J; Gottschall, Jerome L; Michalkiewicz, Michael; Chowdhury, Dhuly; Kor, Daryl J; Looney, Mark R; Matthay, Michael A; Kleinman, Steven H; Brambilla, Donald; Murphy, Edward L

    2018-04-01

    Transfusion-associated circulatory overload is characterized by hydrostatic pulmonary edema following blood transfusion. Restrictive transfusion practice may affect the occurrence and severity of transfusion-associated circulatory overload in critically ill patients. We sought to examine contemporary risk factors and outcomes for transfusion-associated circulatory overload. Case-control study. Four tertiary care hospitals. We prospectively enrolled 200 patients with transfusion-associated circulatory overload identified by active surveillance and 405 controls matched by transfusion intensity. None. Among 20,845 transfused patients who received 128,263 blood components from May 2015 until July 2016, transfusion-associated circulatory overload incidence was one case per 100 transfused patients. In addition to cardiovascular comorbidities, multivariable analysis identified the following independent predictors of transfusion-associated circulatory overload: acute kidney injury, emergency surgery, pretransfusion diuretic use, and plasma transfusion-the latter especially in females. Compared with matched controls, transfusion-associated circulatory overload cases were more likely to require mechanical ventilation (71% vs 49%; p < 0.001), experienced longer intensive care and hospital lengths of stay following transfusion, and had higher mortality (21% vs 11%; p = 0.02) even after adjustment for other potentially confounding variables. Despite restrictive transfusion practice, transfusion-associated circulatory overload remains a frequent complication of transfusion and is an independent risk factor for in-hospital morbidity and mortality. In addition to cardiovascular and renal risk factors, plasma transfusion was associated with transfusion-associated circulatory overload after controlling for other covariates. Additional research is needed to examine the benefit of reduced erythrocyte or plasma exposure in patients at high risk for transfusion-associated circulatory

  8. Enhancement of Arterial Pressure Pulsatility by Controlling Continuous-Flow Left Ventricular Assist Device Flow Rate in Mock Circulatory System.

    PubMed

    Bozkurt, Selim; van de Vosse, Frans N; Rutten, Marcel C M

    Continuous-flow left ventricular assist devices (CF-LVADs) generally operate at a constant speed, which reduces pulsatility in the arteries and may lead to complications such as functional changes in the vascular system, gastrointestinal bleeding, or both. The purpose of this study is to increase the arterial pulse pressure and pulsatility by controlling the CF-LVAD flow rate. A MicroMed DeBakey pump was used as the CF-LVAD. A model simulating the flow rate through the aortic valve was used as a reference model to drive the pump. A mock circulation containing two synchronized servomotor-operated piston pumps acting as left and right ventricles was used as a circulatory system. Proportional-integral control was used as the control method. First, the CF-LVAD was operated at a constant speed. With pulsatile-speed CF-LVAD assistance, the pump was driven such that the same mean pump output was generated. Continuous and pulsatile-speed CF-LVAD assistance provided the same mean arterial pressure and flow rate, while the index of pulsatility increased significantly for both arterial pressure and pump flow rate signals under pulsatile speed pump support. This study shows the possibility of improving the pulsatility of CF-LVAD support by regulating pump speed over a cardiac cycle without reducing the overall level of support.

  9. Design of a hydraulic analog of the circulatory system for evaluating artificial hearts.

    PubMed

    Donovan, F M

    1975-01-01

    A major problem in improving artificial heart designs is the absence of methods for accurate in vitro testing of artificial heart systems. A mock circulatory system has been constructed which hydraulically simulates the systemic and pulmonary circulations of the normal human. The device is constructed of 1/2 in. acrylic sheet and has overall dimensions of 24 in. wide, 16 in. tall, and 8 in. deep. The artificial heart to be tested is attached to the front of the device, and pumps fluid from the systemic venous chamber into the pulmonary arterial chamber and from the pulmonary venous chamber into the systemic arterial chamber. Each of the four chambers is hermetically sealed. The compliance of each chamber is determined by the volume of air trapped above the fluid in that chamber. The pulmonary and systemic resistances are set automatically by bellows-operated valves to simulate the barroreceptor response in the systemic arteries and the passive pulmonary resistance response in the pulmonary arteries. Cardiac output is measured by a turbine flowmeter in the systemic circulation. Results using the Kwan-Gett artificial heart show a good comparison between the mock circulatory system response and the calf response.

  10. Donations After Circulatory Death in Liver Transplant.

    PubMed

    Eren, Emre A; Latchana, Nicholas; Beal, Eliza; Hayes, Don; Whitson, Bryan; Black, Sylvester M

    2016-10-01

    The supply of liver grafts for treatment of end-stage liver disease continues to fall short of ongoing demands. Currently, most liver transplants originate from donations after brain death. Enhanced utilization of the present resources is prudent to address the needs of the population. Donation after circulatory or cardiac death is a mechanism whereby the availability of organs can be expanded. Donations after circulatory death pose unique challenges given their exposure to warm ischemia. Technical principles of donations after circulatory death procurement and pertinent studies investigating patient outcomes, graft outcomes, and complications are highlighted in this review. We also review associated risk factors to suggest potential avenues to achieve improved outcomes and reduced complications. Future considerations and alternative techniques of organ preservation are discussed, which may suggest novel strategies to enhance preservation and donor expansion through the use of marginal donors. Ultimately, without effective measures to bolster organ supply, donations after circulatory death should remain a consideration; however, an understanding of inherent risks and limitations is necessary.

  11. Intraoperative care for aortic surgery using circulatory arrest

    PubMed Central

    Fernández Del Valle, David; González Alvarez, Adrián; Pérez-Lozano, Blanca

    2017-01-01

    The total circulatory arrest (CA) is necessary to achieve optimal surgical conditions in certain aortic pathologies, especially in those affecting the ascending aorta and aortic arch. During this procedure it is necessary to protect all the organs of ischemia, especially those of the central nervous system and for this purpose several strategies have been developed. The first and most important protective method is systemic hypothermia. The degree of hypothermia and the route of application have been evolving and currently tend to use moderate hypothermia (MH) (20.1–28 °C) associated with unilateral or bilateral selective cerebral perfusion methods. In this way the neurological results are better, the interval of security is greater and the times of extracorporeal circulation are smaller. Even so, it is necessary to take into account that there is the possibility of ischemia in the lower part of the body, especially of the abdominal viscera and the spinal cord, therefore the time of circulatory stop should be limited and not to exceed 80 minutes. Evidence of possible neurological drug protection is very weak and only mannitol, magnesium, and statins can produce some benefit. Inhalational anesthetics and some intravenous seem to have advantages, but more studies would be needed to test their long-term benefit. Other important parameters to be monitored during these procedures are blood glucose, anemia and coagulation disorders and acid-base balance. The recommended monitoring is common in complex cardiovascular procedures and it is of special importance the neurological monitoring that can be performed with several techniques, although currently the most used are Bispectral Index (BIS) and Near-Infrared Spectroscopy (NIRS). It is also essential to monitor the temperature routinely at the nasopharyngeal and bladder level and it is important to control coagulation with rotational thromboelastometry (ROTEM). PMID:28616347

  12. Concept designs of nonrotating-type centrifugal blood pump and basic study on output characteristics of the oscillating disk-type centrifugal pump.

    PubMed

    Kabei, N; Tuichiya, K; Sakurai, Y

    1994-09-01

    When designing a turbo-type blood pump as an artificial heart, the gap between a rotating shaft and a pump housing should be perfectly sealed to prevent any leakage or contamination through a seal. In addition, blood coagulation in a blood chamber must be avoided. To overcome these problems, we proposed five different nonrotating-type turbo pumps: a caudal-fin-type axial-flow pump, a caudal-fin-type centrifugal pump, a nutating-column-type centrifugal pump, a nutating-collapsible-tube-type centrifugal pump, and an oscillating-disk-type centrifugal pump. We selected and developed the oscillating-disk-type centrifugal pump that consists of a disk, a driving rod, a seal, an oscillation mechanism, and a pump housing. The disk is mounted on the end of the rod, which is connected to a high-speed DC motor through an oscillation mechanism. The rod and the disk do not rotate, but they oscillate in the pump housing. This movement of the disk generates forward fluid flow around the axis (i.e., the rotational fluid flow). Centrifugal force due to fluid rotation supports the pressure difference between the outlet and the inlet. The diameter of the disk is 39 mm, the maximum inner diameter of the pump housing is 40 mm, and the volume of the blood chamber for 25 degrees' oscillation is 16.9 ml. The performance of the pump was tested in a mock circulatory system.(ABSTRACT TRUNCATED AT 250 WORDS)

  13. [Initial experience with a new blood pump].

    PubMed

    Margreiter, R; Schwab, W; Klima, G; Koller, J; Baum, M; Dietrich, H; Hager, J; Königsrainer, A

    1990-12-01

    A new type of blood pump was tested in calves for 6 hours. The pump consists of a rigid housing with a trochoidal internal surface, an inlet and outlet, and two lateral walls. A two-corner piston rotating on an eccentric shaft, describes a trochoidal path, thus creating a gap seal, the gap measuring a constant 10-35 microns. The pump is driven by a watercooled DC motor. For right ventricular assist, a cannula is inserted into the right ventricle through the right atrium, and into the left ventricle for left ventricular assists. From a total of 10 experiments, two left ventricular assists, two right ventricular assists, and three biventricular assists were evaluated. The pump produced a pulsatile flow of 31 at 70 rpm. Energy requirements were 2.19 watts for left, 2.06 for right, and 7.26 for biventricular assists. Plasma hemoglobin remained as low as 10 mg/dl during monoventricular, and increased during biventricular assists to 20 mg/dl after 3 hours, and returned to 16 mg/dl after 6 hours. From these preliminary results it is concluded that this new rotary blood pump may be suitable as a circulatory assist device.

  14. Donations After Circulatory Death in Liver Transplant

    PubMed Central

    Eren, Emre A.; Latchana, Nicholas; Beal, Eliza; Hayes, Don; Whitson, Bryan; Black, Sylvester M.

    2017-01-01

    The supply of liver grafts for treatment of end-stage liver disease continues to fall short of ongoing demands. Currently, most liver transplants originate from donations after brain death. Enhanced utilization of the present resources is prudent to address the needs of the population. Donation after circulatory or cardiac death is a mechanism whereby the availability of organs can be expanded. Donations after circulatory death pose unique challenges given their exposure to warm ischemia. Technical principles of donations after circulatory death procurement and pertinent studies investigating patient outcomes, graft outcomes, and complications are highlighted in this review. We also review associated risk factors to suggest potential avenues to achieve improved outcomes and reduced complications. Future considerations and alternative techniques of organ preservation are discussed, which may suggest novel strategies to enhance preservation and donor expansion through the use of marginal donors. Ultimately, without effective measures to bolster organ supply, donations after circulatory death should remain a consideration; however, an understanding of inherent risks and limitations is necessary. PMID:27733105

  15. Vascular and Immunobiology of the Circulatory Sphingosine 1-Phosphate Gradient

    PubMed Central

    Yanagida, Keisuke; Hla, Timothy

    2017-01-01

    Vertebrates are endowed with a closed circulatory system, the evolution of which required novel structural and regulatory changes. Furthermore, immune cell trafficking paradigms adapted to the barriers imposed by the closed circulatory system. How did such changes occur mechanistically? We propose that spatial compartmentalization of the lipid mediator sphingosine 1-phosphate (S1P) may be one such mechanism. In vertebrates, S1P is spatially compartmentalized in the blood and lymphatic circulation, thus comprising a sharp S1P gradient across the endothelial barrier. Circulatory S1P has critical roles in maturation and homeostasis of the vascular system as well as in immune cell trafficking. Physiological functions of S1P are tightly linked to shear stress, the key biophysical stimulus from blood flow. Thus, circulatory S1P confinement could be a primordial strategy of vertebrates in the development of a closed circulatory system. This review discusses the cellular and molecular basis of the S1P gradients and aims to interpret its physiological significance as a key feature of the closed circulatory system. PMID:27813829

  16. A mock circulatory system with physiological distribution of terminal resistance and compliance: application for testing the intra-aortic balloon pump.

    PubMed

    Kolyva, Christina; Biglino, Giovanni; Pepper, John R; Khir, Ashraf W

    2012-03-01

    A mock circulatory system (MCS) was designed to replicate a physiological environment for in vitro testing and was assessed with the intra-aortic balloon pump (IABP). The MCS was comprised of an artificial left ventricle (LV), connected to a 14-branch polyurethane-compound aortic model. Physiological distribution of terminal resistance and compliance according to published data was implemented with capillary tubes of different sizes and syringes of varying air volume, respectively, fitted at the outlets of the branches. The ends of the aortic branches were connected to a common tube representing the venous system and an overhead reservoir provided atrial pressure. An IABP operating a 40-cc balloon was set to counterpulsate with the LV. Total arterial compliance of the system was 0.94 mL/mm Hg and total arterial resistance was 20.3 ± 3.3 mm Hg/L/min. At control, physiological flow distribution was achieved and both mean and phasic aortic pressure and flow were physiological. With the IABP, aortic pressure exhibited the major features of counterpulsation: diastolic augmentation during inflation, inflection point at onset of deflation, and end-diastolic reduction at the end of deflation. The contribution of balloon inflation and deflation was also evident on the aortic flow pattern. This MCS was verified to be suitable for IABP testing and with further adaptations it could be used for studying other hemodynamic problems and ventricular assist devices. © 2010, Copyright the Authors. Artificial Organs © 2010, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  17. New methods for the development of pneumatic displacement pumps for cardiac assist.

    PubMed

    Knierbein, B; Rosarius, N; Reul, H; Rau, G

    1990-11-01

    The primary goal of the presented project was to develop a pump family with stroke volumes of 20, 50, 70 and 90 ml, which could be produced at low cost but with sufficient quality. The housing parts of the pump were thermoformed from technical semifinished materials. All blood contacting surfaces of the pump were coated with biomaterials in a controlled dipping process. During the design and fabrication process a professional CAD-system was used. This facilitated spatial presentations of pump components for first evaluations at the initial draft stages. The CAD-design data were then transformed to CNC-controlled lathes and mill's for the fabrication of pump tools. The stresses and strains of the moving blood pump components, such as membranes and valves, were precalculated by means of Finite-Element-Analysis (FEM). After completion of the pump, the internal flow fields were investigated by flow-visualization techniques using non-Newtonian test fluids, and the pump characteristics (function curves) were investigated in appropriate circulatory mock loops. The paper covers all above aspects from first draft to final fabrication and testing.

  18. Baclofen Pumps: Uses and Complications.

    PubMed

    Woolf, Seth M; Baum, Carl R

    2017-04-01

    Intrathecal baclofen therapy, given via an implanted pump in the abdominal wall either as a continuous infusion or bolus dosing, has been used for more than 25 years to treat the spasticity and dystonia associated with various brain and spinal cord conditions. Pediatric clinicians occasionally encounter baclofen pumps, and in the pediatric setting, significant morbidity can arise from their use. This article presents the background, mechanism of action, uses, and complications of intrathecal baclofen therapy and discusses various management strategies should complications occur.

  19. Energy transmission and power sources for mechanical circulatory support devices to achieve total implantability.

    PubMed

    Wang, Jake X; Smith, Joshua R; Bonde, Pramod

    2014-04-01

    Left ventricular assist device therapy has radically improved congestive heart failure survival with smaller rotary pumps. The driveline used to power today's left ventricular assist devices, however, continues to be a source of infection, traumatic damage, and rehospitalization. Previous attempts to wirelessly power left ventricular assist devices using transcutaneous energy transfer systems have been limited by restrictions on separation distance and alignment between the transmit and receive coils. Resonant electrical energy transfer allows power delivery at larger distances without compromising safety and efficiency. This review covers the efforts to wirelessly power mechanical circulatory assist devices and the progress made in enhancing their energy sources. Copyright © 2014 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  20. Comparison of effects of extra-thoracic paraaortic counterpulsation to intraaortic balloon pump on circulatory support in acute heart failure.

    PubMed

    Zhang, Jie-Min; Liu, Xiao-Cheng; Liu, Zhi-Gang; Zhao, Long; Yang, Li; Liu, Tian-Wen; He, Guo-Wei

    2015-11-24

    Previously designed intra-thoracic paraaortic counterpulsation device has limited stroke volume and may depress the lung to cause complications. The purpose of this study was to evaluate the hemodynamic effects of an extra-thoracic paraaortic counterpulsation device (ETPACD) in comparison to intraaortic balloon pump (IABP) in an animal model with acute heart failure. The acute heart failure model was successfully induced by snaring branch of anterior descending coronary artery in sheep (weighting, 38-50 kg, n = 8). The ETPACD is a single port, 65-ml stroke volume blood chamber designed to be connected to descending aorta through a valveless graft and placed extra-thorax. In comparison, a standard clinical 40-ml IABP was placed in the descending aorta. The hemodynamic indices of both devices were recorded during counterpulsation assistance. Two of the sheep were allowed to survive for 1 week to examine the prolonged effect. Both ETPACD and IABP increased cardiac output with higher effect of ETPACD (13.52 % vs. 8.19 % in IABP, P < 0.05) and on mean diastolic aortic pressure (26.73 % vs. 12.58 % in IABP, P < 0.01). Both ETPACD and IABP also produced a greater reduction in left ventricular end-diastolic pressure (26.77 % vs. 23.08 %, P > 0.05). The ETPACD increased left carotid artery flow more significantly the IABP (18.00 % vs. 9.19 % , P < 0.05). In two of the sheep allowed to survive for 1 week, the device worked well with no complications and there was no thrombus formation in the chamber of ETPACD. This study demonstrated that both ETPACD and IABP provided benefit of circulatory support in acute heart failure with better effect on hemodynamic parameters provided by ETPACD. Therefore, ETPACD with theoretical larger stroke volume may become a promising counterpulsation device for treatment of heart failure.

  1. Development of a disposable maglev centrifugal blood pump intended for one-month support in bridge-to-bridge applications: in vitro and initial in vivo evaluation.

    PubMed

    Someya, Takeshi; Kobayashi, Mariko; Waguri, Satoshi; Ushiyama, Tomohiro; Nagaoka, Eiki; Hijikata, Wataru; Shinshi, Tadahiko; Arai, Hirokuni; Takatani, Setsuo

    2009-09-01

    MedTech Dispo, a disposable maglev centrifugal blood pump with two degrees of freedom magnetic suspension and radial magnetic coupling rotation, has been developed for 1-month extracorporeal circulatory support. As the first stage of a two-stage in vivo evaluation, 2-week evaluation of a prototype MedTech Dispo was conducted. In in vitro study, the pump could produce 5 L/min against 800 mm Hg and the normalized index of hemolysis was 0.0054 +/- 0.0008 g/100 L. In in vivo study, the pump, with its blood-contacting surface coated with biocompatible 2-methacryloyloxyethyl phosphorylcholine polymer, was implanted in seven calves in left heart bypass. Pump performance was stable with a mean flow of 4.49 +/- 0.38 L/min at a mean speed of 2072.1 +/- 64.5 rpm. The maglev control revealed its stability in rotor position during normal activity by the calves. During 2 weeks of operation in two calves which survived the intended study period, no thrombus formation was seen inside the pump and levels of plasma free hemoglobin were maintained below 4 mg/dL. Although further experiments are required, the pump demonstrated the potential for sufficient and reliable performance and biocompatibility in meeting the requirements for cardiopulmonary bypass and 1-week circulatory support.

  2. An original valveless artificial heart providing pulsatile flow tested in mock circulatory loops.

    PubMed

    Tozzi, Piergiorgio; Maertens, Audrey; Emery, Jonathan; Joseph, Samuel; Kirsch, Matthias; Avellan, François

    2017-11-24

    We present the test bench results of a valveless total artificial heart that is potentially compatible with the pediatric population. The RollingHeart is a valveless volumetric pump generating pulsatile flow. It consists of a single spherical cavity divided into 4 chambers by 2 rotating disks. The combined rotations of both disks produce changes in the volumes of the 4 cavities (suction and ejection). The blood enters/exits the spherical cavity through 4 openings that are symmetrical to the fixed rotation axis of the first disk.Mock circulatory system: The device pumps a 37% glycerin solution through 2 parallel circuits, simulating the pulmonary and systemic circulations. Flow rates are acquired with a magnetic inductive flowmeter, while pressure sensors collect pressure in the left and right outflow and inflow tracts.In vitro test protocol: The pump is run at speeds ranging from 20 to 180 ejections per minute. The waveform of the pressure generated at the inflow and outflow of the 4 chambers and the flow rate in the systemic circulation are measured. At an ejection rate of 178 min-1, the RollingHeart pumps 5.3 L/min for a systemic maximal pressure gradient of 174 mmHg and a pulmonary maximal pressure gradient of 75 mmHg. The power input was 14 W, corresponding to an efficiency of 21%. The RollingHeart represents a new approach in the domain of total artificial heart. This preliminary study endorses the feasibility of a single valveless device acting as a total artificial heart.

  3. Feasibility of a miniature centrifugal rotary blood pump for low-flow circulation in children and infants.

    PubMed

    Takatani, Setsuo; Hoshi, Hideo; Tajima, Kennichi; Ohuchi, Katsuhiro; Nakamura, Makoto; Asama, Junichio; Shimshi, Tadahiko; Yoshikawa, Masaharu

    2005-01-01

    In this study, a seal-less, tiny centrifugal rotary blood pump was designed for low-flow circulatory support in children and infants. The design was targeted to yield a compact and priming volume of 5 ml with a flow rate of 0.5-4 l/min against a head pressure of 40-100 mm Hg. To meet the design requirements, the first prototype had an impeller diameter of 30 mm with six straight vanes. The impeller was supported with a needle-type hydrodynamic bearing and was driven with a six-pole radial magnetic driver. The external pump dimensions included a pump head height of 20 mm, diameter of 49 mm, and priming volume of 5 ml. The weight was 150 g, including the motor driver. In the mock circulatory loop, using fresh porcine blood, the pump yielded a flow of 0.5-4.0 l/min against a head pressure of 40-100 mm Hg at a rotational speed of 1800-4000 rpm using 1/4" inflow and outflow conduits. The maximum flow and head pressure of 5.25 l/min and 244 mm Hg, respectively, were obtained at a rotational speed of 4400 rpm. The maximum electrical-to-hydraulic efficiency occurred at a flow rate of 1.5-3.5 l/min and at a rotational speed of 2000-4400 rpm. The normalized index of hemolysis, which was evaluated using fresh porcine blood, was 0.0076 g/100 l with the impeller in the down-mode and a bearing clearance of 0.1 mm. Further refinement in the bearing and magnetic coupler are required to improve the hemolytic performance of the pump. The durability of the needle-type hydrodynamic bearing and antithrombotic performance of the pump will be performed before clinical applications. The tiny centrifugal blood pump meets the flow requirements necessary to support the circulation of pediatric patients.

  4. Mechanical circulatory support in pediatrics.

    PubMed

    Steffen, Robert J; Miletic, Kyle G; Schraufnagel, Dean P; Vargo, Patrick R; Fukamachi, Kiyotaka; Stewart, Robert D; Moazami, Nader

    2016-05-01

    End-stage heart failure affects thousands of children yearly and mechanical circulatory support is used at many points in their care. Extracorporeal membrane oxygenation supports both the failing heart and lungs, which has led to its use as an adjunct to cardiopulmonary resuscitation as well as in post-operative cardiogenic shock. Continuous-flow ventricular assist devices (VAD) have replaced pulsatile-flow devices in adults and early studies have shown promising results in children. The Berlin paracorporeal pulsatile VAD recently gained U.S. Food and Drug Administration approval and remains the only VAD approved in pediatrics. Failing univentricular hearts and other congenitally corrected lesions are new areas for mechanical support. Finding novel uses, improving durability, and minimizing complications are areas of growth in pediatric mechanical circulatory support.

  5. Circulatory nucleosome levels are significantly increased in early and late-onset preeclampsia.

    PubMed

    Zhong, Xiao Yan; Gebhardt, Stefan; Hillermann, Renate; Tofa, Kashefa Carelse; Holzgreve, Wolfgang; Hahn, Sinuhe

    2005-08-01

    Elevations in circulatory DNA, as measured by real-time PCR, have been observed in pregnancies with manifest preeclampsia. Recent reports have indicated that circulatory nucleosome levels are elevated in the periphery of cancer patients. We have now examined whether circulatory nucleosome levels are similarly elevated in cases with preeclampsia. Maternal plasma samples were prepared from 17 cases with early onset preeclampsia (<34 weeks gestation) with 14 matched normotensive controls, as well as 15 cases late-onset preeclampsia (>34 weeks gestation) with 10 matched normotensive controls. Levels of circulatory nucleosomes were quantified by commercial ELISA (enzyme-linked immunosorbant assay). The level of circulatory nucleosomes was significantly elevated in both study preeclampsia groups, compared to the matched normotensive control group (p = 0.000 and p = 0.001, respectively). Our data suggests that preeclampsia is associated with the elevated presence of circulatory nucleosomes, and that this phenomenon occurs in both early- and late-onset forms of the disorder. Copyright 2005 John Wiley & Sons, Ltd.

  6. Self sufficient wireless transmitter powered by foot-pumped urine operating wearable MFC.

    PubMed

    Taghavi, M; Stinchcombe, A; Greenman, J; Mattoli, V; Beccai, L; Mazzolai, B; Melhuish, C; Ieropoulos, I A

    2015-12-10

    The first self-sufficient system, powered by a wearable energy generator based on microbial fuel cell (MFC) technology is introduced. MFCs made from compliant material were developed in the frame of a pair of socks, which was fed by urine via a manual gaiting pump. The simple and single loop cardiovascular fish circulatory system was used as the inspiration for the design of the manual pump. A wireless programmable communication module, engineered to operate within the range of the generated electricity, was employed, which opens a new avenue for research in the utilisation of waste products for powering portable as well as wearable electronics.

  7. Risk Factors and Outcomes in Transfusion-associated Circulatory Overload

    PubMed Central

    Murphy, Edward L.; Kwaan, Nicholas; Looney, Mark R.; Gajic, Ognjen; Hubmayr, Rolf D.; Gropper, Michael A.; Koenigsberg, Monique; Wilson, Greg; Matthay, Michael; Bacchetti, Peter; Toy, Pearl

    2013-01-01

    BACKGROUND Transfusion-associated circulatory overload is characterized by new respiratory distress and hydrostatic pulmonary edema within 6 hours after blood transfusion, but its risk factors and outcomes are poorly characterized. METHODS Using a case control design, we enrolled 83 patients with severe transfusion-associated circulatory overload identified by active surveillance for hypoxemia and 163 transfused controls at the University of California, San Francisco (UCSF) and Mayo Clinic (Rochester, Minn) hospitals. Odds ratios (OR) and 95% confidence intervals (CI) were calculated using multivariable logistic regression, and survival and length of stay were analyzed using proportional hazard models. RESULTS Transfusion-associated circulatory overload was associated with chronic renal failure (OR 27.0; 95% CI, 5.2–143), a past history of heart failure (OR 6.6; 95% CI, 2.1–21), hemorrhagic shock (OR 113; 95% CI, 14.1–903), number of blood products transfused (OR 1.11 per unit; 95% CI, 1.01–1.22), and fluid balance per hour (OR 9.4 per liter; 95% CI, 3.1–28). Patients with transfusion-associated circulatory overload had significantly increased in-hospital mortality (hazard ratio 3.20; 95% CI, 1.23–8.10) after controlling for Acute Physiology and Chronic Health Evaluation-II (APACHE-II) score, and longer hospital and intensive care unit lengths of stay. CONCLUSIONS The risk of transfusion-associated circulatory overload increases with the number of blood products administered and a positive fluid balance, and in patients with pre-existing heart failure and chronic renal failure. These data, if replicated, could be used to construct predictive algorithms for transfusion-associated circulatory overload, and subsequent modifications of transfusion practice might prevent morbidity and mortality associated with this complication. PMID:23357450

  8. Effects of Endurance and Endurance Strength Training on Body Composition and Physical Capacity in Women with Abdominal Obesity.

    PubMed

    Skrypnik, Damian; Bogdański, Paweł; Mądry, Edyta; Karolkiewicz, Joanna; Ratajczak, Marzena; Kryściak, Jakub; Pupek-Musialik, Danuta; Walkowiak, Jarosław

    2015-01-01

    To compare the effects of endurance training with endurance strength training on the anthropometric, body composition, physical capacity, and circulatory parameters in obese women. 44 women with abdominal obesity were randomized into groups A and B, and asked to perform endurance (A) and endurance strength training (B) for 3 months, 3 times/week, for 60 min. Dual-energy X-ray absorptiometry and Graded Exercise Test were performed before and after training. Significant decreases in body mass, BMI, total body fat, total body fat mass, and waist and hip circumference were observed after both types of intervention. Marked increases in total body lean and total body fat-free mass were documented in group B. In both groups, significant increases in peak oxygen uptake, time to exhaustion, maximal work rate, and work rate at ventilatory threshold were accompanied by noticeably decreased resting heart rate, resting systolic blood pressure, and resting and exercise diastolic blood pressure. No significant differences were noticed between groups for the investigated parameters. Our findings demonstrate evidence for a favorable and comparable effect of 3-month endurance and endurance strength training on anthropometric parameters, body composition, physical capacity, and circulatory system function in women with abdominal obesity. © 2015 S. Karger GmbH, Freiburg.

  9. Effects of Endurance and Endurance Strength Training on Body Composition and Physical Capacity in Women with Abdominal Obesity

    PubMed Central

    Skrypnik, Damian; Bogdański, Paweł; Mądry, Edyta; Karolkiewicz, Joanna; Ratajczak, Marzena; Kryściak, Jakub; Pupek-Musialik, Danuta; Walkowiak, Jarosław

    2015-01-01

    Aims To compare the effects of endurance training with endurance strength training on the anthropometric, body composition, physical capacity, and circulatory parameters in obese women. Methods 44 women with abdominal obesity were randomized into groups A and B, and asked to perform endurance (A) and endurance strength training (B) for 3 months, 3 times/week, for 60 min. Dual-energy X-ray absorptiometry and Graded Exercise Test were performed before and after training. Results Significant decreases in body mass, BMI, total body fat, total body fat mass, and waist and hip circumference were observed after both types of intervention. Marked increases in total body lean and total body fat-free mass were documented in group B. In both groups, significant increases in peak oxygen uptake, time to exhaustion, maximal work rate, and work rate at ventilatory threshold were accompanied by noticeably decreased resting heart rate, resting systolic blood pressure, and resting and exercise diastolic blood pressure. No significant differences were noticed between groups for the investigated parameters. Conclusion Our findings demonstrate evidence for a favorable and comparable effect of 3-month endurance and endurance strength training on anthropometric parameters, body composition, physical capacity, and circulatory system function in women with abdominal obesity. PMID:25968470

  10. Regional perfusion by extracorporeal membrane oxygenation of abdominal organs from donors after circulatory death: a systematic review.

    PubMed

    Shapey, Iestyn M; Muiesan, Paolo

    2013-12-01

    Organs from donors after circulatory death (DCDs) are particularly susceptible to the effects of warm ischemia injury. Regional perfusion (RP) by extracorporeal membrane oxygenation (ECMO) is increasingly being advocated as a useful remedy to the effects of ischemia/reperfusion injury, and it has been reported to enable the transplantation of organs from donors previously deemed unsuitable. The MEDLINE, Embase, and Cochrane databases were searched, and articles published between 1997 and 2013 were obtained. A systematic review was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Two hundred ten articles were identified, and 11 were eligible for inclusion. Four hundred eighty-two kidneys and 79 livers were transplanted from regional perfusion-supported donor after circulatory death (RP-DCD) sources. One-year graft survival was lower with uncontrolled RP-DCD liver transplantation, whereas 1-year patient survival was similar. Primary nonfunction and ischemic cholangiopathy were significantly more frequent with RP-DCDs versus donors after brain death (DBDs), but there was no difference in postoperative mortality between the 2 groups. The 1-year patient and graft survival rates for RP-DCD kidney transplantation were better than the rates with standard DCDs and were comparable to, if not better than, the rates with DBDs. At experienced centers, delayed graft function (DGF) for kidney transplantation from RP-DCDs was much less frequent in comparison with all other donor types. In conclusion, RP aids the recovery of DCD organs from ischemic injury and enables transplantation with acceptable survival. RP may help to increase the donor pool, but its benefits must still be balanced with the recognition of significantly higher rates of complications in liver transplantation. In kidney transplantation, significant reductions in DGF can be obtained with RP, and there are potentially important implications for long

  11. The Future of Adult Cardiac Assist Devices: Novel Systems and Mechanical Circulatory Support Strategies

    PubMed Central

    Bartoli, Carlo R.; Dowling, Robert D.

    2011-01-01

    Synopsis The recent, widespread success of mechanical circulatory support has ushered in a new era of cardiovascular medicine in which numerous implantable devices exist to treat advanced heart failure. As cardiac assist devices gain prevalence in the clinical management of cardiovascular disease, it is increasingly important to raise awareness of novel device systems, the unique mechanisms by which they function, and implications for patient management. In this article, we present state-of-the-art devices that are currently under development or in clinical trials. Devices are categorized as Standard Full-Support (HeartMate III, CorAide, Evaheart LVAS), Less-Invasive Full-Support (MVAD), Partial-Support (CircuLite Synergy Pocket Micro-Pump, Reitan Catheter Pump, Procyrion CAD, C-Pulse, Symphony Counterpulsation Device) Right Ventricular Assist Device (RVAD; DexAide, Impella RD Recover, Impella RP), and Total Artificial Heart (TAH; CardioWest, AbioCor II, Continuous-Flow TAH, Continuous-Flow BiVAD). Implantation strategy, mechanism of action, durability, efficacy, hemocompatibility, and human factors such as quality of life during device support are considered. The feasibility of novel strategies for unloading the failing heart is examined. PMID:22062206

  12. Strain measurement of abdominal aortic aneurysm with real-time 3D ultrasound speckle tracking.

    PubMed

    Bihari, P; Shelke, A; Nwe, T H; Mularczyk, M; Nelson, K; Schmandra, T; Knez, P; Schmitz-Rixen, T

    2013-04-01

    Abdominal aortic aneurysm rupture is caused by mechanical vascular tissue failure. Although mechanical properties within the aneurysm vary, currently available ultrasound methods assess only one cross-sectional segment of the aorta. This study aims to establish real-time 3-dimensional (3D) speckle tracking ultrasound to explore local displacement and strain parameters of the whole abdominal aortic aneurysm. Validation was performed on a silicone aneurysm model, perfused in a pulsatile artificial circulatory system. Wall motion of the silicone model was measured simultaneously with a commercial real-time 3D speckle tracking ultrasound system and either with laser-scan micrometry or with video photogrammetry. After validation, 3D ultrasound data were collected from abdominal aortic aneurysms of five patients and displacement and strain parameters were analysed. Displacement parameters measured in vitro by 3D ultrasound and laser scan micrometer or video analysis were significantly correlated at pulse pressures between 40 and 80 mmHg. Strong local differences in displacement and strain were identified within the aortic aneurysms of patients. Local wall strain of the whole abdominal aortic aneurysm can be analysed in vivo with real-time 3D ultrasound speckle tracking imaging, offering the prospect of individual non-invasive rupture risk analysis of abdominal aortic aneurysms. Copyright © 2013 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  13. Medical care expenditures for selected circulatory diseases: opportunities for reducing national health expenditures.

    PubMed

    Hodgson, T A; Cohen, A J

    1999-10-01

    Circulatory system diseases are a significant burden in terms of morbidity, mortality, and use of health care services. This article presents total, per capita, and per condition US medical care expenditures in 1995 for circulatory diseases according to sex, age, and type of health service. Total personal health care expenditures estimated by the Health Care Financing Administration for each type of health care service are separated into components to estimate patient expenditures by age, sex, primary medical diagnosis, and health care service for all diseases of the circulatory system, heart disease, coronary heart disease, congestive heart failure, hypertensive disease, and cerebrovascular disease. Expenditures for circulatory diseases totaled $127.8 billion in 1995 (17% of all personal health care expenditures), $486 per capita, and $1,636 per condition. Approximately one half of expenditures was for hospital care and 20% was for nursing home care. Heart disease accounted for 60% of circulatory expenditures. Expenditures increased with age and reached 35% of expenditures among persons aged 85 years and older, which was almost $7,000 per capita. These relationships vary somewhat according to the specific circulatory disease, type of health care, and age. Expenditures increase with age and circulatory diseases can be expected to command an increasing share of national health expenditures as the number and proportion of the population that is elderly grows. The alteration of lifestyles and medical interventions provide many opportunities to prevent circulatory diseases and to reduce national health expenditures.

  14. The CentriMag: a new optimized centrifugal blood pump with levitating impeller.

    PubMed

    Mueller, Juerg Peter; Kuenzli, Andreas; Reuthebuch, Oliver; Dasse, Kurt; Kent, Stella; Zuend, Gregor; Turina, Marko Ivan; Lachat, Mario Louis

    2004-01-01

    Blood pumps are routinely used for circulatory and pulmonary support. However, blood trauma and pump failure remain severe drawbacks of currently available pump models. This study evaluated the first clinical application of a new, totally bearingless centrifugal blood pump (CentriMag). A centrifugal pump consisting of an electromagnetic suspended impeller was used as a blood pump during beating-heart coronary artery bypass grafting in 11 patients (mean weight, 77.4 kg). Heparin in a bolus of 150 IU/kg body weight was administered, and activated clotting time was maintained at approximately 180 to 250 seconds during extracorporeal circulation. Pump-induced blood trauma was evaluated by measurement of plasma free hemoglobin (PFH), lactate dehydrogenase (LDH), hematocrit, total bilirubin, and platelet levels. Mean pump flow was 3.3 +/- 0.62 L/min, and mean pressure gradient through the oxygenator was 69 +/- 4 mm Hg. No pump dysfunction occurred during a mean application time of 105 +/- 26 minutes. Inspection of the pump housings showed no internal thrombus formation despite low-dose heparinization. Only slight hemolysis was observed with a mean PFH level of 1.96 micromol/L; LDH, 460 U/L; hematocrit, 33%; total bilirubin, 25 micromol/L; and platelets, 191 x 10(3)/microL. The bearingless CentriMag blood pump is a safe and reliable new device that produces only minimal hemolysis. It seems to be suited for long-term evaluation as a blood pump for extracorporeal membrane oxygenation or as ventricular assist device.

  15. Benefits of ambulatory axillary intra-aortic balloon pump for circulatory support as bridge to heart transplant.

    PubMed

    Umakanthan, Ramanan; Hoff, Steven J; Solenkova, Natalia; Wigger, Mark A; Keebler, Mary E; Lenneman, Andrew; Leacche, Marzia; Disalvo, Thomas G; Ooi, Henry; Naftilan, Allen J; Byrne, John G; Ahmad, Rashid M

    2012-05-01

    Axillary intra-aortic balloon pump therapy has been described as a bridge to transplant. Advantages over femoral intra-aortic balloon pump therapy include reduced incidence of infection and enhanced patient mobility. We identified the patients who would benefit most from this therapy while awaiting heart transplantation. We conducted a single-center, retrospective observational study to evaluate outcomes from axillary intra-aortic balloon pump therapy. These included hemodynamic parameters, duration of support, and success in bridging to transplant. We selected patients on the basis of history of sternotomy, elevated panel-reactive antibody, and small body habitus. Patients were made to ambulate aggressively beginning on postoperative day 1. Between September 2007 and September 2010, 18 patients underwent axillary intra-aortic balloon pump therapy. All patients had the devices placed through the left axillary artery with a Hemashield side graft (Boston Scientific, Natick, Mass). Before axillary placement, patients underwent femoral placement to demonstrate hemodynamic benefit. Duration of support ranged from 5 to 63 days (median = 19 days). There was marked improvement in ambulatory potential and hemodynamic parameters, with minimal blood transfusion requirements. There were no device-related infections. Some 72% of the patients (13/18) were successfully bridged to transplantation. Axillary intra-aortic balloon pump therapy provides excellent support for selected patients as a bridge to transplant. The majority of the patients were successfully bridged to transplant and discharged. Although this therapy has been described in previous studies, this is the largest series to incorporate a regimen of aggressive ambulation with daily measurements of distances walked. Copyright © 2012. Published by Mosby, Inc.

  16. A review of selected pumping systems in nature and engineering--potential biomimetic concepts for improving displacement pumps and pulsation damping.

    PubMed

    Bach, D; Schmich, F; Masselter, T; Speck, T

    2015-09-03

    The active transport of fluids by pumps plays an essential role in engineering and biology. Due to increasing energy costs and environmental issues, topics like noise reduction, increase of efficiency and enhanced robustness are of high importance in the development of pumps in engineering. The study compares pumps in biology and engineering and assesses biomimetic potentials for improving man-made pumping systems. To this aim, examples of common challenges, applications and current biomimetic research for state-of-the art pumps are presented. The biomimetic research is helped by the similar configuration of many positive displacement pumping systems in biology and engineering. In contrast, the configuration and underlying pumping principles for fluid dynamic pumps (FDPs) differ to a greater extent in biology and engineering. However, progress has been made for positive displacement as well as for FDPs by developing biomimetic devices with artificial muscles and cilia that improve energetic efficiency and fail-safe operation or reduce noise. The circulatory system of vertebrates holds a high biomimetic potential for the damping of pressure pulsations, a common challenge in engineering. Damping of blood pressure pulsation results from a nonlinear viscoelastic behavior of the artery walls which represent a complex composite material. The transfer of the underlying functional principle could lead to an improvement of existing technical solutions and be used to develop novel biomimetic damping solutions. To enhance efficiency or thrust of man-made fluid transportation systems, research on jet propulsion in biology has shown that a pulsed jet can be tuned to either maximize thrust or efficiency. The underlying principle has already been transferred into biomimetic applications in open channel water systems. Overall there is a high potential to learn from nature in order to improve pumping systems for challenges like the reduction of pressure pulsations, increase of jet

  17. Successful repair of injured hepatic veins and inferior vena cava following blunt traumatic injury, by using cardiopulmonary bypass and hypothermic circulatory arrest.

    PubMed

    Kaoutzanis, Christodoulos; Evangelakis, Erotokritos; Kokkinos, Chrysostomos; Kaoutzanis, Gavriel

    2011-01-01

    Traumatic injury to the retrohepatic veins continues to carry high mortality rates. In the last few decades various management strategies have been proposed. However, treatment of such injuries still remains highly variable and technically challenging due to the surgically inaccessible location of these vessels and the consequent difficulty controlling bleeding. We report a successful repair of complete transection of the two main extraparenchymal hepatic veins and laceration of the retrohepatic inferior vena cava using cardiopulmonary bypass (CPB) and hypothermic circulatory arrest (HCA) following blunt abdominal trauma. Immediate CPB with or without HCA can be life-saving and should be considered for patients with complex isolated retrohepatic venous injuries.

  18. Blacks' Death Rate Due to Circulatory Diseases Is Positively Related to Whites' Explicit Racial Bias.

    PubMed

    Leitner, Jordan B; Hehman, Eric; Ayduk, Ozlem; Mendoza-Denton, Rodolfo

    2016-10-01

    Perceptions of racial bias have been linked to poorer circulatory health among Blacks compared with Whites. However, little is known about whether Whites' actual racial bias contributes to this racial disparity in health. We compiled racial-bias data from 1,391,632 Whites and examined whether racial bias in a given county predicted Black-White disparities in circulatory-disease risk (access to health care, diagnosis of a circulatory disease; Study 1) and circulatory-disease-related death rate (Study 2) in the same county. Results revealed that in counties where Whites reported greater racial bias, Blacks (but not Whites) reported decreased access to health care (Study 1). Furthermore, in counties where Whites reported greater racial bias, both Blacks and Whites showed increased death rates due to circulatory diseases, but this relationship was stronger for Blacks than for Whites (Study 2). These results indicate that racial disparities in risk of circulatory disease and in circulatory-disease-related death rate are more pronounced in communities where Whites harbor more explicit racial bias.

  19. 2015 SCAI/ACC/HFSA/STS Clinical Expert Consensus Statement on the Use of Percutaneous Mechanical Circulatory Support Devices in Cardiovascular Care (Endorsed by the American Heart Association, the Cardiological Society of India, and Sociedad Latino Americana de Cardiologia Intervencion; Affirmation of Value by the Canadian Association of Interventional Cardiology-Association Canadienne de Cardiologie d'intervention).

    PubMed

    Rihal, Charanjit S; Naidu, Srihari S; Givertz, Michael M; Szeto, Wilson Y; Burke, James A; Kapur, Navin K; Kern, Morton; Garratt, Kirk N; Goldstein, James A; Dimas, Vivian; Tu, Thomas

    2015-06-01

    Although historically the intra-aortic balloon pump has been the only mechanical circulatory support device available to clinicians, a number of new devices have become commercially available and have entered clinical practice. These include axial flow pumps, such as Impella(®); left atrial to femoral artery bypass pumps, specifically the TandemHeart; and new devices for institution of extracorporeal membrane oxygenation. These devices differ significantly in their hemodynamic effects, insertion, monitoring, and clinical applicability. This document reviews the physiologic impact on the circulation of these devices and their use in specific clinical situations. These situations include patients undergoing high-risk percutaneous coronary intervention, those presenting with cardiogenic shock, and acute decompensated heart failure. Specialized uses for right-sided support and in pediatric populations are discussed and the clinical utility of mechanical circulatory support devices is reviewed, as are the American College of Cardiology/American Heart Association clinical practice guidelines. Copyright © 2015. Published by Elsevier Inc.

  20. Neonatal circulatory failure due to acute hypertensive crisis: clinical and echocardiographic clues.

    PubMed

    Louw, Jacoba; Brown, Stephen; Thewissen, Liesbeth; Smits, Anne; Eyskens, Benedicte; Heying, Ruth; Cools, Bjorn; Levtchenko, Elena; Allegaert, Karel; Gewillig, Marc

    2013-04-01

    Circulatory failure due to acute arterial hypertension in the neonatal period is rare. This study was undertaken to assess the clinical and echocardiographic manifestations of circulatory failure resulting from acute neonatal hypertensive crisis. Neonatal and cardiology databases from 2007 to 2010 were reviewed. An established diagnosis of circulatory failure due to neonatal hypertension before the age of 14 days was required for inclusion. Six patients were identified. Five patients presented with circulatory failure due to an acute hypertensive crisis. The median age at presentation was 8.5 days (range: 6.0-11.0) with a median body weight of 3.58 kg (range: 0.86-4.70). Echocardiography demonstrated mild left ventricular dysfunction [median shortening fraction (SF) 25%, range 10-30] and mild aortic regurgitation in 83% (5/6) of patients. One patient with left ventricular dysfunction (SF = 17%) had a large apical thrombus. Two patients were hypotensive, and hypertension only became evident after restoration of cardiac output. Administration of intravenous milrinone was successful, with rapid improvement of the clinical condition. Left ventricular function normalised in all survivors. Early neonatal circulatory collapse due to arterial hypertension is a rare but potentially life-threatening condition. At presentation, hypotension, especially in the presence of a dysfunctional left ventricle, does not exclude a hypertensive crisis being the cause of circulatory failure. The echocardiographic presence of mild aortic regurgitation combined with left ventricular hypocontractility in a structurally normal heart should alert the physician to the presence of underlying hypertension.

  1. Management of pump thrombosis in patients with left ventricular assist devices.

    PubMed

    Stulak, John M; Sharma, Shashank; Maltais, Simon

    2015-04-01

    The gradual evolution of left ventricular assist device (LVAD) therapy has resulted in a durable option for patients as either a bridge to transplantation (BTT) or a destination therapy (DT). Outcomes with current continuous-flow devices continue to demonstrate significant patient benefit, not only in enhanced survival but also in improved functional capacity and quality of life. While the lessening of adverse events through time has resulted in more widespread adoption of this therapy, there continues to be unintended consequences, including, most notably, infection, bleeding, and thrombosis. Beginning in 2011, centers and collaborative groups began to observe a significant increase in the incidence of pump thrombosis with the HeartMate II LVAD (Thoratec Corp., Pleasanton, CA, USA). However, this clinical scourge is not limited to the HeartMate II, as the HeartWare Ventricular Assist System (HVAD; HeartWare Inc., Framingham, MA, USA) has also had these same issues, which led to pump modifications and the appreciation of more strict control of blood pressure and anticoagulation with this pump design. We review the current status of the field of mechanical circulatory support in its approach to diagnosis, management, and prevention of LVAD pump thrombosis.

  2. Unusual placement of intrathecal baclofen pumps: report of two cases.

    PubMed

    Devine, Oliver; Harborne, Andrew; Lo, William B; Weinberg, Daniel; Ciras, Mahesh; Price, Rupert

    2016-01-01

    Intrathecal baclofen delivery via implantable pump represents an important modality for symptomatic relief in patients with chronic spasticity. Pumps are routinely implanted subcutaneously in the anterior abdominal wall. We describe two unusual cases where skin-related complications necessitated revision surgery in order to relocate the pump to alternative sites. The first patient was an international power canoeist, whose strenuous exercise programme interfered with his pump's original siting. The second patient was a cachectic university student with a history of cerebral palsy, who maintained low body mass despite attempted weight gain. The relocation of these two intrathecal devices to the medial compartment of the right thigh and right iliac fossa, respectively, is described.

  3. Generation of OH Radical by Ultrasonic Irradiation in Batch and Circulatory Reactor

    NASA Astrophysics Data System (ADS)

    Fang, Yu; Shimizu, Sayaka; Yamamoto, Takuya; Komarov, Sergey

    2018-03-01

    Ultrasonic technology has been widely investigated in the past as one of the advance oxidation processes to treat wastewater, in this process acoustic cavitation causes generation of OH radical, which play a vital role in improving the treatment efficiency. In this study, OH radical formation rate was measured in batch and circulatory reactor by using Weissler reaction at various ultrasound output power. It is found that the generation rate in batch reactor is higher than that in circulatory reactor at the same output power. The generation rate tended to be slower when output power exceeds 137W. The optimum condition for circulatory reactor was found to be 137W output and 4L/min flow rate. Results of aluminum foil erosion test revealed a strong dependence of cavitation zone length on the ultrasound output power. This is assumed to be one of the reasons why the generation rate of HO radicals becomes slower at higher output power in circulatory reactor.

  4. Intra-Abdominal Hypertension and Abdominal Compartment Syndrome after Abdominal Wall Reconstruction: Quaternary Syndromes?

    PubMed

    Kirkpatrick, A W; Nickerson, D; Roberts, D J; Rosen, M J; McBeth, P B; Petro, C C; Berrevoet, Frederik; Sugrue, M; Xiao, Jimmy; Ball, C G

    2017-06-01

    Reconstruction with reconstitution of the container function of the abdominal compartment is increasingly being performed in patients with massive ventral hernia previously deemed inoperable. This situation places patients at great risk of severe intra-abdominal hypertension and abdominal compartment syndrome if organ failure ensues. Intra-abdominal hypertension and especially abdominal compartment syndrome may be devastating systemic complications with systematic and progressive organ failure and death. We thus reviewed the pathophysiology and reported clinical experiences with abnormalities of intra-abdominal pressure in the context of abdominal wall reconstruction. Bibliographic databases (1950-2015), websites, textbooks, and the bibliographies of previously recovered articles for reports or data relating to intra-abdominal pressure, intra-abdominal hypertension, and the abdominal compartment syndrome in relation to ventral, incisional, or abdominal hernia repair or abdominal wall reconstruction. Surgeons should thus consider and carefully measure intra-abdominal pressure and its resultant effects on respiratory parameters and function during abdominal wall reconstruction. The intra-abdominal pressure post-operatively will be a result of the new intra-peritoneal volume and the abdominal wall compliance. Strategies surgeons may utilize to ameliorate intra-abdominal pressure rise after abdominal wall reconstruction including temporizing paralysis of the musculature either temporarily or semi-permanently, pre-operative progressive pneumoperitoneum, permanently removing visceral contents, or surgically releasing the musculature to increase the abdominal container volume. In patients without complicating shock and inflammation, and in whom the abdominal wall anatomy has been so functionally adapted to maximize compliance, intra-abdominal hypertension may be transient and tolerable. Intra-abdominal hypertension/abdominal compartment syndrome in the specific setting of

  5. Blood circulatory system for noninvasive diagnostics

    NASA Astrophysics Data System (ADS)

    Fricke, D.; Kraitl, J.; Ewald, H.

    2013-02-01

    Based on the human circulatory system, an artificial blood circulatory system was developed to allow the controlled variation of the following blood parameters: total hemoglobin concentration (ctHb), oxyhemoglobin (O2Hb) methemoglobin (MetHb) and carboxyhemoglobin (COHb). The optical properties of the blood were observed by online spectrometer measurements. The purpose of this was to observe and quantify the absorption, transmission and scattering properties of human whole blood in the wavelength range of 400 to 1700 nm. All the non-invasive measurements of the whole blood transmission-spectra were compared with sample results obtained by a Blood Gas Analyzer (BGA) to validate the results. For all measurements, donor erythrocyte concentrates were used. The concentration of hemoglobin was changed by adding fixed amounts of blood plasma to the erythrocyte concentrate. Oxygen saturation and COHb were adjusted by a continuous flow of N2, N2-CO and compressed air through a hollow fibre membrane oxygenator. Different methemoglobin concentrations were adjusted by using natrium nitrite. The blood temperature was kept constant at 37 °C via a tube heating mechanism, with a separate circulation of water passing through the membrane Oxygenator. The Temperature and pressure of the system were automatically controlled and monitored. The model was also used to test new non-invasive measurement systems, and for this reason special cuvettes were designed to imitate human tissue and generate plethysmographical signals. In the future, the blood circulatory system has the potential to be used for testing, validating and also to calibrate newly developed optical prototype devices. It can also be used to further investigate blood components of interest.

  6. 2015 SCAI/ACC/HFSA/STS Clinical Expert Consensus Statement on the Use of Percutaneous Mechanical Circulatory Support Devices in Cardiovascular Care (Endorsed by the American Heart Association, the Cardiological Society of India, and Sociedad Latino Americana de Cardiologia Intervencion; Affirmation of Value by the Canadian Association of Interventional Cardiology-Association Canadienne de Cardiologie D'intervention).

    PubMed

    Rihal, Charanjit S; Naidu, Srihari S; Givertz, Michael M; Szeto, Wilson Y; Burke, James A; Kapur, Navin K; Kern, Morton; Garratt, Kirk N; Goldstein, James A; Dimas, Vivian; Tu, Thomas

    2015-06-01

    Although historically the intra-aortic balloon pump has been the only mechanical circulatory support device available to clinicians, a number of new devices have become commercially available and have entered clinical practice. These include axial flow pumps, such as Impella®; left atrial to femoral artery bypass pumps, specifically the TandemHeart; and new devices for institution of extracorporeal membrane oxygenation. These devices differ significantly in their hemodynamic effects, insertion, monitoring, and clinical applicability. This document reviews the physiologic impact on the circulation of these devices and their use in specific clinical situations. These situations include patients undergoing high-risk percutaneous coronary intervention, those presenting with cardiogenic shock, and acute decompensated heart failure. Specialized uses for right-sided support and in pediatric populations are discussed and the clinical utility of mechanical circulatory support devices is reviewed, as are the American College of Cardiology/American Heart Association clinical practice guidelines. © 2015 by The Society for Cardiovascular Angiography and Interventions, The American College of Cardiology Foundation, The Heart Failure Society of America, and The Society for Thoracic Surgery.

  7. Pathophysiological roles of peroxynitrite in circulatory shock

    PubMed Central

    Szabó, Csaba; Módis, Katalin

    2014-01-01

    Summary Peroxynitrite is a reactive oxidant produced from nitric oxide (NO) and superoxide, which reacts with proteins, lipids and DNA and promotes cytotoxic and pro-inflammatory responses. Here we overview the role of peroxynitrite in various forms of circulatory shock. Immunohistochemical and biochemical evidence demonstrate the production of peroxynitrite in various experimental models of endotoxic and hemorrhagic shock, both in rodents and in large animals. In addition, biological markers of peroxynitrite have been identified in human tissues after circulatory shock. Peroxynitrite can initiate toxic oxidative reactions in vitro and in vivo. Initiation of lipid peroxidation, direct inhibition of mitochondrial respiratory chain enzymes, inactivation of glyceraldehyde-3-phosphate dehydrogenase, inhibition of membrane Na+/K+ ATP-ase activity, inactivation of membrane sodium channels, and other oxidative protein modifications contribute to the cytotoxic effect of peroxynitrite. In addition, peroxynitrite is a potent trigger of DNA strand breakage, with subsequent activation of the nuclear enzyme poly (ADP-ribose) polymerase (PARP), which promotes cellular energetic collapse and cellular necrosis. Additional actions of peroxynitrite that contribute to the pathogenesis of shock include inactivation of catecholamines and catecholamine receptors (leading to vascular failure), endothelial and epithelial injury (leading to endothelial and epithelial hyper-permeability and barrier dysfunction) as well as myocyte injury (contributing to loss of cardiac contractile function). Neutralization of peroxynitrite with potent peroxynitrite decomposition catalysts provides cytoprotective and beneficial effects in rodent and large animal models of circulatory shock. PMID:20523270

  8. Design and principle of operation of the HeartMate PHP (percutaneous heart pump).

    PubMed

    Van Mieghem, Nicolas M; Daemen, Joost; den Uil, Corstiaan; Dur, Onur; Joziasse, Linda; Maugenest, Anne-Marie; Fitzgerald, Keif; Parker, Chris; Muller, Paul; van Geuns, Robert-Jan

    2018-02-20

    The HeartMate PHP (percutaneous heart pump) is a second-generation transcatheter axial flow circulatory support system. The collapsible catheter pump is inserted through a 14 Fr sheath, deployed across the aortic valve expanding to 24 Fr and able to deliver up to 5 L/min blood flow at minimum haemolytic risk. As such, this device may be a valuable adjunct to percutaneous coronary intervention (PCI) of challenging lesions in high-risk patients or treatment of cardiogenic shock. This technical report discusses: (i) the HeartMate PHP concept, (ii) the implantation technique, (iii) the haemodynamic performance in an in vitro cardiovascular flow testing set-up, and (iv) preliminary clinical experience. An update on the device, produced by St. Jude Medical/Abbott Laboratories, can be found in the Appendix.

  9. Development of an in-vitro circulatory system with known resistance and capacitance

    NASA Technical Reports Server (NTRS)

    Offerdahl, C. D.; Schaub, J. D.; Koenig, S. C.; Swope, R. D.; Ewert, D. L.; Convertino, V. A. (Principal Investigator)

    1996-01-01

    An in-vitro (hydrodynamic) model of the circulatory system was developed. The model consisted of a pump, compliant tubing, and valves for resistance. The model is used to simulate aortic pressure and flow. These parameters were measured using a Konigsburg Pressure transducer and a Triton ART2 flow probe. In addition, venous pressure and flow were measured on the downstream side of the resistance. The system has a known compliance and resistance. Steady and pulsatile flow tests were conducted to determine the resistance of the model. A static compliance test was used to determine the compliance of the system. The aortic pressure and flow obtained from the hydrodynamic model will be used to test the accuracy of parameter estimation models such as the 2-element and 4-element Windkessel models and the 3-element Westkessel model. Verifying analytical models used in determining total peripheral resistance (TPR) and systemic arterial compliance (SAC) is important because it provides insight into hemodynamic parameters that indicate baroreceptor responsiveness to situations such as changes in gravitational acceleration.

  10. Transition of intestinal fatty acid-binding protein on hypothermic circulatory arrest with cardiopulmonary bypass.

    PubMed

    Kano, Hiroya; Takahashi, Hiroaki; Inoue, Takeshi; Tanaka, Hiroshi; Okita, Yutaka

    2017-04-01

    Intestinal fatty acid-binding protein (I-FABP) is increasingly employed as a highly specific marker of intestinal necrosis. However, the value of this marker associated with cardiovascular surgery with hypothermic circulatory arrest is unclear. The aim of this study was to measure serum I-FABP levels and provide the transition of I-FABP levels with hypothermic circulatory arrest to help in the management of intestinal perfusion. From August 2011 to September 2013, 33 consecutive patients who had aortic arch surgery with hypothermic circulatory arrest or heart valve surgery performed were enrolled in the study. Twenty patients had aortic surgery with hypothermic (23-29°C) circulatory arrest and 13 patients had heart valve surgery with cardiopulmonary bypass (33°C). I-FABP levels increased, both in patients undergoing aortic surgery with hypothermic circulatory arrest and heart valve surgery with cardiopulmonary bypass, reaching peak levels shortly after the administration of protamine. I-FABP levels in patients with aortic surgery were significantly higher with circulatory arrest. They reached peak levels immediately after recirculation and there was a significant drop at the end of surgery (p<0.001). I-FABP levels in heart valve surgery were gradually increased, with the highest at the administration of protamine; they gradually decreased. Peak I-FABP levels were significantly higher in patients undergoing aortic surgery with hypothermic circulatory arrest than in patients with heart valve surgery. However, no postoperative reperfusion injury occurred in the intestinal tract due to the use of hypothermic organ protection. Plasma I-FABP monitoring could be a valuable method for finding an intestinal ischemia in patients with cardiovascular surgery.

  11. Representations of the Human Circulatory System

    ERIC Educational Resources Information Center

    Lopez-Manjon, Asuncion; Angon, Yolanda Postigo

    2009-01-01

    There is no agreement about the robustness of intuitive representations of the circulatory system and their susceptibility to change by instruction. In this paper, we analyse to what extent students with varying degrees of biology instruction and different ages (High School Health Science and Social Science students and first and final year…

  12. Mass Transport: Circulatory System with Emphasis on Nonendothermic Species.

    PubMed

    Crossley, Dane A; Burggren, Warren W; Reiber, Carl L; Altimiras, Jordi; Rodnick, Kenneth J

    2016-12-06

    Mass transport can be generally defined as movement of material matter. The circulatory system then is a biological example given its role in the movement in transporting gases, nutrients, wastes, and chemical signals. Comparative physiology has a long history of providing new insights and advancing our understanding of circulatory mass transport across a wide array of circulatory systems. Here we focus on circulatory function of nonmodel species. Invertebrates possess diverse convection systems; that at the most complex generate pressures and perform at a level comparable to vertebrates. Many invertebrates actively modulate cardiovascular function using neuronal, neurohormonal, and skeletal muscle activity. In vertebrates, our understanding of cardiac morphology, cardiomyocyte function, and contractile protein regulation by Ca2+ highlights a high degree of conservation, but differences between species exist and are coupled to variable environments and body temperatures. Key regulators of vertebrate cardiac function and systemic blood pressure include the autonomic nervous system, hormones, and ventricular filling. Further chemical factors regulating cardiovascular function include adenosine, natriuretic peptides, arginine vasotocin, endothelin 1, bradykinin, histamine, nitric oxide, and hydrogen sulfide, to name but a few. Diverse vascular morphologies and the regulation of blood flow in the coronary and cerebral circulations are also apparent in nonmammalian species. Dynamic adjustments of cardiovascular function are associated with exercise on land, flying at high altitude, prolonged dives by marine mammals, and unique morphology, such as the giraffe. Future studies should address limits of gas exchange and convective transport, the evolution of high arterial pressure across diverse taxa, and the importance of the cardiovascular system adaptations to extreme environments. © 2017 American Physiological Society. Compr Physiol 7:17-66, 2017. Copyright © 2017 John

  13. Underuse of medication for circulatory disorders among unmarried women and men in Norway?

    PubMed

    Kravdal, Øystein; Grundy, Emily

    2014-11-24

    It is well established that unmarried people have higher mortality from circulatory diseases and higher all-cause mortality than the married, and these marital status differences seem to be increasing. However, much remains to be known about the underlying mechanisms. Our objective was to examine marital status differences in the purchase of medication for circulatory diseases, and risk factors for them, which may indicate underuse of such medication by some marital status groups. Using data from registers covering the entire Norwegian population, we analysed marital status differences in the purchase of medicine for eight circulatory disorders by people aged 50-79 in 2004-2008. These differences were compared with those in circulatory disease mortality during 2004-2007, considered as indicating probable differences in disease burden. The unmarried had 1.4-2.8 times higher mortality from the four types of circulatory diseases considered. However, the never-married in particular purchased less medicine for these diseases, or precursor risk factors of these diseases, primarily because of a low chance of making a first purchase. The picture was more mixed for the divorced and widowed. Both groups purchased less of some of these medicines than the married, but, especially in the case of the widowed, relatively more of other types of medicine. In contrast to the never-married, divorced and widowed people were as least as likely as the married to make a first purchase, but adherence rates thereafter, indicated by continuing purchases, were lower. The most plausible interpretation of the findings is that compared with married people, especially the never-married more often have circulatory disorders that are undiagnosed or for which they for other reasons underuse medication. Inadequate use of these potentially very efficient medicines in such a large population group is a serious public health challenge which needs further investigation. It is possible that marital

  14. Directed Retrograde Cerebral Protection during Moderate Hypothermic Circulatory Arrest

    PubMed Central

    Yacoubian, Vahe; Jyrala, Aarne; Kay, Gregory L.

    2006-01-01

    There are many choices for neurologic protection for aortic arch surgery. Although numerous investigators have challenged the efficacy of retrograde cerebral perfusion, we have had good results with our application of this technique. We performed a retrospective review of 8 consecutive patients who underwent surgery from 1 June 2001 through 31 March 2003; the age range was 33 to 97 years. All patients required circulatory arrest and underwent retrograde cerebral perfusion with use of a tourniquet on the patients' left and right arms above the elbow to direct retrograde flow to the brain. Moderate hypothermia (around 24 °C nasopharyngeal) was used; circulatory arrest time ranged from 27 to 63 minutes. There was 1 late hospital death due to multiple-organ system failure. There were no neurologic complications (stroke or temporary neurologic dysfunction). There was no substantive neurologic or renal dysfunction in this cohort, in which moderate hypothermia was used. These results are comparable to those reported in the literature for similar patients. We conclude that, for patients who require circulatory arrest, directed retrograde cerebral perfusion at moderate nasopharyngeal hypothermia gives results comparable to those reported with other techniques. PMID:17215968

  15. Aortic arch reconstruction: deep and moderate hypothermic circulatory arrest with selective antegrade cerebral perfusion.

    PubMed

    Wu, YanWen; Xiao, LiQiong; Yang, Ting; Wang, Lei; Chen, Xin

    2017-07-01

    To compare the effects of moderate and deep hypothermic circulatory arrest (DHCA) with selective antegrade cerebral perfusion (SACP) during aortic arch surgery in adult patients and to offer the evidence for the detection of the temperature which provides best brain protection in the subjects who accept aortic arch reconstruction surgery. A total of 109 patients undergoing surgery of the aortic arch were divided into the moderate hypothermic circulatory arrest group (Group I) and the deep hypothermic circulatory arrest group (Group II). We recorded the data of the patients and their cardiopulmonary bypass (CPB) time, aortic clamping time, SACP time and postoperative anesthetized recovery time, tracheal intubation time, time in the intensive care unit (ICU) and postoperative neurologic dysfunction. Patient characteristics were similar in the two groups. There were four patients who died in Group II and 1 patient in Group I. There were no significant differences in aortic clamping time of each group (111.4±58.4 vs. 115.9±16.2) min; SACP time (27.4±5.9 vs. 23.5±6.1) min of the moderate hypothermic circulatory arrest group and the deep hypothermic circulatory arrest group; there were significant differences in cardiopulmonary bypass time (207.4±20.9 vs. 263.8±22.6) min, postoperative anesthetized recovery time (19.0±11.1 vs. 36.8±25.3) hours, extubation time (46.4±15.1 vs. 64.4±6.0) hours; length of stay in the intensive care unit (ICU) (4.7±1.7 vs. 8±2.3) days and postoperative neurologic dysfunction in the two groups. Compared to deep hypothermic circulatory arrest, moderate hypothermic circulatory arrest can provide better brain protection and achieve good clinical results.

  16. Baclofen pump catheter leakage after migration of the abdominal catheter in a pediatric patient with spasticity.

    PubMed

    Dastgir, Amer; Ranalli, Nathan J; MacGregor, Theresa L; Aldana, Philipp R

    2015-09-01

    The authors report an unusual case of intrathecal baclofen withdrawal due to the perforation and subsequent leakage of a baclofen pump catheter in a patient with spastic cerebral palsy. A 15-year-old boy underwent an uncomplicated placement of an intrathecal baclofen pump for the treatment of spasticity due to cerebral palsy. After excellent control of symptoms for 3 years, the patient presented to the emergency department with increasing tremors following a refill of his baclofen pump. Initial evaluation consisted of radiographs of the pump and catheter, which appeared normal, and a successful aspiration of CSF from the pump's side port. A CT dye study revealed a portion of the catheter directly overlying the refill port and extravasation of radiopaque dye into the subfascial pocket anterior to the pump. During subsequent revision surgery, a small puncture hole in the catheter was seen to be leaking the drug. The likely cause of the puncture was an inadvertent perforation of the catheter by a needle during the refilling of the pump. This case report highlights a unique complication in a patient with an intrathecal baclofen pump. Physicians caring for these patients should be aware of this rare yet potential complication in patients presenting with baclofen withdrawal symptoms.

  17. Mechanical Circulatory Support of the Right Ventricle for Adult and Pediatric Patients With Heart Failure.

    PubMed

    Chopski, Steven G; Murad, Nohra M; Fox, Carson S; Stevens, Randy M; Throckmorton, Amy L

    2018-05-10

    The clinical implementation of mechanical circulatory assistance for a significantly dysfunctional or failing left ventricle as a bridge-to-transplant or bridge-to-recovery is on the rise. Thousands of patients with left-sided heart failure are readily benefitting from these life-saving technologies, and left ventricular failure often leads to severe right ventricular dysfunction or failure. Right ventricular failure (RVF) has a high rate of mortality caused by the risk of multisystem organ failure and prolonged hospitalization for patients after treatment. The use of a blood pump to support the left ventricle also typically results in an increase in right ventricular preload and may impair right ventricular contractility during left ventricular unloading. Patients with RVF might also suffer from severe pulmonary dysfunction, cardiac defects, congenital heart disease states, or a heterogeneity of cardiophysiologic challenges because of symptomatic congestive heart failure. Thus, the uniqueness and complexity of RVF is emerging as a new domain of significant clinical interest that motivates the development of right ventricular assist devices. In this review, we present the current state-of-the-art for clinically used blood pumps to support adults and pediatric patients with right ventricular dysfunction or failure concomitant with left ventricular failure. New innovative devices specifically for RVF are also highlighted. There continues to be a compelling need for novel treatment options to support patients with significant right heart dysfunction or failure.

  18. Clinical and prognostic role of ammonia in advanced decompensated heart failure. The cardio-abdominal syndrome?

    PubMed

    Frea, Simone; Bovolo, Virginia; Pidello, Stefano; Canavosio, Federico G; Botta, Michela; Bergerone, Serena; Gaita, Fiorenzo

    2015-09-15

    Advanced heart failure is associated with end-organ damage. Recent literature suggested an intriguing crosstalk between failing heart, abdomen and kidneys. Venous ammonia, as a by-product of the gut, could be a marker of abdominal injury in heart failure patients. The aim of the study was to investigate the clinical and prognostic role of ammonia in patients with advanced decompensated heart failure (ADHF). 90 patients admitted with ADHF were prospectively studied. The prognostic role of ammonia at admission was evaluated. Primary end-points were: a composite of cardiac death, urgent heart transplantation and mechanical circulatory support at 3 months and need for renal replacement therapies (RRT). In the study cohort (age 59.0 ± 12.0 years, FE 21.6 ± 9.0%, INTERMACS profile 3.7 ± 0.9, creatinine 1.71 ± 0.95 mg/dl) 27 patients (30%) underwent the cardiac composite endpoint, while 9 patients (10%) needed RRT. At ROC curve analysis ammonia ≥ 130 μg/dl (abdominal damage) showed the best diagnostic accuracy. At multivariate analysis abdominal damage predicted the cardiac composite endpoint. Abdominal damage further increased risk among patient with cold profile at admission (HR 2.7, 95% CI 1.1-7.0, p = 0.046). At multivariate analysis abdominal damage also predicted need for RRT (OR 10.8, 95% CI 1.5-75.8, p = 0.017). The combined use of estimated right atrial pressure and ammonia showed the highest diagnostic accuracy and a very high specificity in prediction of need for RRT. In a selected population admitted for ADHF ammonia, as a marker of abdominal derangement, predicted adverse cardiac events and need for RRT. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  19. Biventricular support with the Jarvik 2000 axial flow pump: a feasibility study.

    PubMed

    Radovancevic, Branislav; Gregoric, Igor D; Tamez, Daniel; Vrtovec, Bojan; Tuzun, Egemen; Chee, Hyun Keun; Moore, Sheila; Jarvik, Robert K; Frazier, O H

    2003-01-01

    Patients with congestive heart failure who are supported with a left ventricular assist device (LVAD) may experience right ventricular dysfunction or failure that requires support with a right ventricular assist device (RVAD). To determine the feasibility of using a clinically available axial flow ventricular assist device as an RVAD, we implanted Jarvik 2000 pumps in the left ventricle and right atrium of two Corriente crossbred calves (approximately 100 kg each) by way of a left thoracotomy and then analyzed the hemodynamic effects in the mechanically fibrillated heart at various LVAD and RVAD speeds. Right atrial implantation of the device required no modification of either the device or the surgical technique used for left ventricular implantation. Satisfactory biventricular support was achieved during fibrillation as evidenced by an increase in mean aortic pressure from 34 mm Hg with the pumps off to 78 mm Hg with the pumps generating a flow rate of 4.8 L/min. These results indicate that the Jarvik 2000 pump, which can provide chronic circulatory support and can be powered by external batteries, is a feasible option for right ventricular support after LVAD implantation and is capable of completely supporting the circulation in patients with global heart failure.

  20. Cannula Tip With Integrated Volume Sensor for Rotary Blood Pump Control: Early-Stage Development.

    PubMed

    Cysyk, Joshua; Newswanger, Ray; Popjes, Eric; Pae, Walter; Jhun, Choon-Sik; Izer, Jenelle; Weiss, William; Rosenberg, Gerson

    2018-05-10

    The lack of direct measurement of left ventricular unloading is a significant impediment to the development of an automatic speed control system for continuous-flow left ventricular assist devices (cf-LVADs). We have developed an inlet cannula tip for cf-LVADs with integrated electrodes for volume sensing based on conductance. Four platinum-iridium ring electrodes were installed into grooves on a cannula body constructed from polyetheretherketone (PEEK). A sinusoidal current excitation waveform (250 μA pk-pk, 50 kHz) was applied across one pair of electrodes, and the conductance-dependent voltage was sensed across the second pair of electrodes. The conductance catheter was tested in an acute ovine model (n = 3) in conjunction with the HeartMate II rotary blood pump to provide circulatory support and unload the ventricle. Echocardiography was used to measure ventricular size during pump support for verification for the conductance measurements. The conductance measurements correlated linearly with the echocardiography dimension measurements more than the full range of pump support from minimum support to suction. This cannula tip will enable the development of automatic control systems to optimize pump support based on a real-time measurement of ventricular size.

  1. Belgian modified classification of Maastricht for donors after circulatory death.

    PubMed

    Evrard, P

    2014-11-01

    "Non-heart-beating donors," or, in a more recent and international definition, "donors after circulatory death," are a potential and additional group of deceased persons who are able to add organs to the pool. A new classification is proposed on the basis of the result of a consensus of experts issued from all Belgian transplant centers. The first level of definition is simple and based on whether the situation is uncontrolled (categories I and II) or controlled (categories III, IV, and V). In category I, the patient is declared "dead on arrival" and, in category II, there is an "unsuccessful resuscitation" whether it occurred out or in the hospital for both situations. Category III is the most usual situation in which the treating physician and family are "awaiting cardiac arrest" to declare the death of the patient. Category IV is always characterized by "cardiac arrest during brain death." The special situation of the Belgian law allowing the euthanasia is elaborated in category V, "euthanasia," and includes patients who grant access to medically assisted circulatory death. Organ donation after euthanasia is allowed under the scope of donation after circulatory death. This classification conserves the skeleton of the Maastricht one, as it is simple and clear, but classifies easily the different donors after circulatory death types by processes for ethical issues and for the non-medical or non-specialized reader interested in the field. This is also an argument for public consideration and trust in the difficult field of organ donation.

  2. Functional and biocompatibility performances of an integrated Maglev pump-oxygenator.

    PubMed

    Zhang, Tao; Cheng, Guangming; Koert, Andrew; Zhang, Juntao; Gellman, Barry; Yankey, G Kwame; Satpute, Aditee; Dasse, Kurt A; Gilbert, Richard J; Griffith, Bartley P; Wu, Zhongjun J

    2009-01-01

    To provide respiratory support for patients with lung failure, a novel compact integrated pump-oxygenator is being developed. The functional and biocompatibility performances of this device are presented. The pump-oxygenator is designed by combining a magnetically levitated pump/rotor with a uniquely configured hollow fiber membrane bundle to create an assembly free, ultracompact, all-in-one system. The hemodynamics, gas transfer and biocompatibility performances of this novel device were investigated both in vitro in a circulatory flow loop and in vivo in an ovine animal model. The in vitro results showed that the device was able to pump blood flow from 2 to 8 L/min against a wide range of pressures and to deliver an oxygen transfer rate more than 300 mL/min at a blood flow of 6 L/min. Blood damage tests demonstrated low hemolysis (normalized index of hemolysis [NIH] approximately 0.04) at a flow rate of 5 L/min against a 100-mm Hg afterload. The data from five animal experiments (4 h to 7 days) demonstrated that the device could bring the venous blood to near fully oxygen-saturated condition (98.6% +/- 1.3%). The highest oxygen transfer rate reached 386 mL/min. The gas transfer performance was stable over the study duration for three 7-day animals. There was no indication of blood damage. The plasma free hemoglobin and platelet count were within the normal ranges. No gross thrombus is found on the explanted pump components and fiber surfaces. Both in vitro and in vivo results demonstrated that the newly developed pump-oxygenator can achieve sufficient blood flow and oxygen transfer with excellent biocompatibility.

  3. Canadian Guidelines for Controlled Pediatric Donation After Circulatory Determination of Death—Summary Report*

    PubMed Central

    Hornby, Laura; Rochwerg, Bram; van Manen, Michael; Dhanani, ; Sonny; Sivarajan, V. Ben; Appleby, Amber; Bennett, Mary; Buchman, Daniel; Farrell, Catherine; Goldberg, Aviva; Greenberg, Rebecca; Singh, Ram; Nakagawa, Thomas A.; Witteman, William; Barter, Jill; Beck, Allon; Coughlin, Kevin; Conradi, Alf; Cupido, Cynthia; Dawson, Rosanne; Dipchand, Anne; Freed, Darren; Hornby, Karen; Langlois, Valerie; Mack, Cheryl; Mahoney, Meagan; Manhas, Deepak; Tomlinson, Christopher; Zavalkoff, Samara; Shemie, Sam D.

    2017-01-01

    Objectives: Create trustworthy, rigorous, national clinical practice guidelines for the practice of pediatric donation after circulatory determination of death in Canada. Methods: We followed a process of clinical practice guideline development based on World Health Organization and Canadian Medical Association methods. This included application of Grading of Recommendations Assessment, Development, and Evaluation methodology. Questions requiring recommendations were generated based on 1) 2006 Canadian donation after circulatory determination of death guidelines (not pediatric specific), 2) a multidisciplinary symposium of national and international pediatric donation after circulatory determination of death leaders, and 3) a scoping review of the pediatric donation after circulatory determination of death literature. Input from these sources drove drafting of actionable questions and Good Practice Statements, as defined by the Grading of Recommendations Assessment, Development, and Evaluation group. We performed additional literature reviews for all actionable questions. Evidence was assessed for quality using Grading of Recommendations Assessment, Development, and Evaluation and then formulated into evidence profiles that informed recommendations through the evidence-to-decision framework. Recommendations were revised through consensus among members of seven topic-specific working groups and finalized during meetings of working group leads and the planning committee. External review was provided by pediatric, critical care, and critical care nursing professional societies and patient partners. Results: We generated 63 Good Practice Statements and seven Grading of Recommendations Assessment, Development, and Evaluation recommendations covering 1) ethics, consent, and withdrawal of life-sustaining therapy, 2) eligibility, 3) withdrawal of life-sustaining therapy practices, 4) ante and postmortem interventions, 5) death determination, 6) neonatal pediatric donation

  4. Canadian Guidelines for Controlled Pediatric Donation After Circulatory Determination of Death-Summary Report.

    PubMed

    Weiss, Matthew J; Hornby, Laura; Rochwerg, Bram; van Manen, Michael; Dhanani, Sonny; Sivarajan, V Ben; Appleby, Amber; Bennett, Mary; Buchman, Daniel; Farrell, Catherine; Goldberg, Aviva; Greenberg, Rebecca; Singh, Ram; Nakagawa, Thomas A; Witteman, William; Barter, Jill; Beck, Allon; Coughlin, Kevin; Conradi, Alf; Cupido, Cynthia; Dawson, Rosanne; Dipchand, Anne; Freed, Darren; Hornby, Karen; Langlois, Valerie; Mack, Cheryl; Mahoney, Meagan; Manhas, Deepak; Tomlinson, Christopher; Zavalkoff, Samara; Shemie, Sam D

    2017-11-01

    Create trustworthy, rigorous, national clinical practice guidelines for the practice of pediatric donation after circulatory determination of death in Canada. We followed a process of clinical practice guideline development based on World Health Organization and Canadian Medical Association methods. This included application of Grading of Recommendations Assessment, Development, and Evaluation methodology. Questions requiring recommendations were generated based on 1) 2006 Canadian donation after circulatory determination of death guidelines (not pediatric specific), 2) a multidisciplinary symposium of national and international pediatric donation after circulatory determination of death leaders, and 3) a scoping review of the pediatric donation after circulatory determination of death literature. Input from these sources drove drafting of actionable questions and Good Practice Statements, as defined by the Grading of Recommendations Assessment, Development, and Evaluation group. We performed additional literature reviews for all actionable questions. Evidence was assessed for quality using Grading of Recommendations Assessment, Development, and Evaluation and then formulated into evidence profiles that informed recommendations through the evidence-to-decision framework. Recommendations were revised through consensus among members of seven topic-specific working groups and finalized during meetings of working group leads and the planning committee. External review was provided by pediatric, critical care, and critical care nursing professional societies and patient partners. We generated 63 Good Practice Statements and seven Grading of Recommendations Assessment, Development, and Evaluation recommendations covering 1) ethics, consent, and withdrawal of life-sustaining therapy, 2) eligibility, 3) withdrawal of life-sustaining therapy practices, 4) ante and postmortem interventions, 5) death determination, 6) neonatal pediatric donation after circulatory

  5. 2015 SCAI/ACC/HFSA/STS Clinical Expert Consensus Statement on the Use of Percutaneous Mechanical Circulatory Support Devices in Cardiovascular Care: Endorsed by the American Heart Assocation, the Cardiological Society of India, and Sociedad Latino Americana de Cardiologia Intervencion; Affirmation of Value by the Canadian Association of Interventional Cardiology-Association Canadienne de Cardiologie d'intervention.

    PubMed

    Rihal, Charanjit S; Naidu, Srihari S; Givertz, Michael M; Szeto, Wilson Y; Burke, James A; Kapur, Navin K; Kern, Morton; Garratt, Kirk N; Goldstein, James A; Dimas, Vivian; Tu, Thomas

    2015-05-19

    Although historically the intra-aortic balloon pump has been the only mechanical circulatory support device available to clinicians, a number of new devices have become commercially available and have entered clinical practice. These include axial flow pumps, such as Impella(®); left atrial to femoral artery bypass pumps, specifically the TandemHeart; and new devices for institution of extracorporeal membrane oxygenation. These devices differ significantly in their hemodynamic effects, insertion, monitoring, and clinical applicability. This document reviews the physiologic impact on the circulation of these devices and their use in specific clinical situations. These situations include patients undergoing high-risk percutaneous coronary intervention, those presenting with cardiogenic shock, and acute decompensated heart failure. Specialized uses for right-sided support and in pediatric populations are discussed and the clinical utility of mechanical circulatory support devices is reviewed, as are the American College of Cardiology/American Heart Association clinical practice guidelines. Copyright © 2015 The Society for Cardiovascular Angiography and Interventions, The American College of Cardiology Foundation, The Heart Failure Society of America, and The Society for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  6. Circulatory Insufficiency and Hypotension Related to the Ductus Arteriosus in Neonates

    PubMed Central

    Rios, Danielle R.; Bhattacharya, Soume; Levy, Philip T.; McNamara, Patrick J.

    2018-01-01

    The biological role of the ductus arteriosus (DA) in neonates varies from an innocent bystander role during normal postnatal transition, to a supportive role when there is compromise to either systemic or pulmonary blood flow, to a pathological state in the presence of hemodynamically significant systemic to pulmonary shunts, as occurs in low birth weight infants. Among a wide array of clinical manifestations arising due to the ductal entity, systemic circulatory insufficiency and hypotension are of significant concern as they are particularly challenging to manage. An understanding of the physiologic interplay between the DA and the circulatory system is the key to developing appropriate targeted therapeutic strategies. In this review, we discuss the relationship of systemic hypotension to the DA, emphasizing the importance of critical thinking and a precise individual approach to intensive care support. We particularly focus on the variable states of hypotension arising directly due to a hemodynamically significant DA or seen in the period following successful surgical ligation. In addition, we explore the mechanistic contributions of the ductus to circulatory insufficiency that may manifest during the transitional period, states of maladapted transition (such as acute pulmonary hypertension of the newborn), and congenital heart disease (both ductal dependent and non-ductal dependent lesions). Understanding the dynamic modulator role of the ductus according to the ambient physiology enables a more precise approach to management. We review the pathophysiology, clinical manifestations, diagnosis, monitoring, and therapeutic intervention for the spectrum of DA-related circulatory compromise. PMID:29600242

  7. Analysis of Dose Response for Circulatory Disease After Radiotherapy for Benign Disease

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Little, Mark P., E-mail: mark.little@nih.gov; Kleinerman, Ruth A.; Stovall, Marilyn

    Purpose: To assess the shape of the dose-response for various circulatory disease endpoints, and modifiers by age and time since exposure. Methods and Materials: This was an analysis of the US peptic ulcer data testing for heterogeneity of radiogenic risk by circulatory disease endpoint (ischemic heart, cerebrovascular, other circulatory disease). Results: There were significant excess risks for all circulatory disease, with an excess relative risk Gy{sup -1} of 0.082 (95% CI 0.031-0.140), and ischemic heart disease, with an excess relative risk Gy{sup -1} of 0.102 (95% CI 0.039-0.174) (both p = 0.01), and indications of excess risk for stroke. Theremore » were no statistically significant (p > 0.2) differences between risks by endpoint, and few indications of curvature in the dose-response. There were significant (p < 0.001) modifications of relative risk by time since exposure, the magnitude of which did not vary between endpoints (p > 0.2). Risk modifications were similar if analysis was restricted to patients receiving radiation, although the relative risks were slightly larger and the risk of stroke failed to be significant. The slopes of the dose-response were generally consistent with those observed in the Japanese atomic bomb survivors and in occupationally and medically exposed groups. Conclusions: There were excess risks for a variety of circulatory diseases in this dataset, with significant modification of risk by time since exposure. The consistency of the dose-response slopes with those observed in radiotherapeutically treated groups at much higher dose, as well as in lower dose-exposed cohorts such as the Japanese atomic bomb survivors and nuclear workers, implies that there may be little sparing effect of fractionation of dose or low-dose-rate exposure.« less

  8. Is moderate hypothermic circulatory arrest with selective antegrade cerebral perfusion superior to deep hypothermic circulatory arrest in elective aortic arch surgery?

    PubMed

    Poon, Shi Sum; Estrera, Anthony; Oo, Aung; Field, Mark

    2016-09-01

    A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was whether moderate hypothermia circulatory arrest with selective antegrade cerebral perfusion (SACP) is more beneficial than deep hypothermic circulatory arrest in elective aortic arch surgery. Altogether, 1028 papers were found using the reported search, of which 6 represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. There were four retrospective observational studies, one prospective randomized controlled trial and one meta-analysis study. There were no local or neuromuscular complications related to axillary arterial cannulation reported. In the elective setting, four studies showed that the in-hospital mortality for moderate hypothermia is consistently low, ranging from 1.0 to 4.3%. In a large series of hemiarch replacement comparing 682 cases of deep hypothermia with 94 cases of moderate hypothermia with SACP, 20 cases (2.8%) of permanent neurological deficit were reported, compared to 3 cases (3.2%) in moderate hypothermia. Three observational studies and a meta-analysis study did not identify an increased risk of postoperative renal failure and dialysis following either deep or moderate hypothermia although a higher incidence of stroke was reported in the meta-analysis study with deep hypothermia (12.7 vs 7.3%). Longer cardiopulmonary bypass time and circulatory arrest time were reported in four studies for deep hypothermia, suggesting an increased time required for systemic cooling and rewarming in that group. Overall, these findings suggested that in elective aortic arch surgery, moderate hypothermia with selective antegrade cerebral perfusion adapted to the duration of circulatory arrest can be performed safely with acceptable mortality and morbidity outcomes. The risk of spinal cord

  9. Analysis of pressure head-flow loops of pulsatile rotodynamic blood pumps.

    PubMed

    Jahren, Silje E; Ochsner, Gregor; Shu, Fangjun; Amacher, Raffael; Antaki, James F; Vandenberghe, Stijn

    2014-04-01

    The clinical importance of pulsatility is a recurring topic of debate in mechanical circulatory support. Lack of pulsatility has been identified as a possible factor responsible for adverse events and has also demonstrated a role in myocardial perfusion and cardiac recovery. A commonly used method for restoring pulsatility with rotodynamic blood pumps (RBPs) is to modulate the speed profile, synchronized to the cardiac cycle. This introduces additional parameters that influence the (un)loading of the heart, including the timing (phase shift) between the native cardiac cycle and the pump pulses, and the amplitude of speed modulation. In this study, the impact of these parameters upon the heart-RBP interaction was examined in terms of the pressure head-flow (HQ) diagram. The measurements were conducted using a rotodynamic Deltastream DP2 pump in a validated hybrid mock circulation with baroreflex function. The pump was operated with a sinusoidal speed profile, synchronized to the native cardiac cycle. The simulated ventriculo-aortic cannulation showed that the level of (un)loading and the shape of the HQ loops strongly depend on the phase shift. The HQ loops displayed characteristic shapes depending on the phase shift. Increased contribution of native contraction (increased ventricular stroke work [WS ]) resulted in a broadening of the loops. It was found that the previously described linear relationship between WS and the area of the HQ loop for constant pump speeds becomes a family of linear relationships, whose slope depends on the phase shift. © 2013 Wiley Periodicals, Inc. and International Center for Artificial Organs and Transplantation.

  10. The Circulatory System. Instructional Materials in Anatomy and Physiology for Pennsylvania Health Occupations Programs.

    ERIC Educational Resources Information Center

    National Evaluation Systems, Inc., Amherst, MA.

    This instructional modular unit with instructor's guide provides materials on aspects of one of the major systems of the human body--the circulatory system. Its purpose is to introduce the student to the structures and functions of the human circulatory system--and the interrelationships of the two--and to familiarize the student with some of the…

  11. Abdominal Adhesions

    MedlinePlus

    ... Clearinghouse What are abdominal adhesions? Abdominal adhesions are bands of fibrous tissue that can form between abdominal ... Esophagus Stomach Large intestine Adhesion Abdominal adhesions are bands of fibrous tissue that can form between abdominal ...

  12. Abdominal Pain

    MedlinePlus

    ... and Recurrent or Functional Abdominal Pain (RAP or FAP) What is abdominal pain? Abdominal pain , or stomachache, ... recurrent abdominal pain (RAP) or functional abdominal pain (FAP)? If your health care provider has ruled out ...

  13. Computational design and in vitro characterization of an integrated maglev pump-oxygenator.

    PubMed

    Zhang, Juntao; Taskin, M Ertan; Koert, Andrew; Zhang, Tao; Gellman, Barry; Dasse, Kurt A; Gilbert, Richard J; Griffith, Bartley P; Wu, Zhongjun J

    2009-10-01

    For the need for respiratory support for patients with acute or chronic lung diseases to be addressed, a novel integrated maglev pump-oxygenator (IMPO) is being developed as a respiratory assist device. IMPO was conceptualized to combine a magnetically levitated pump/rotor with uniquely configured hollow fiber membranes to create an assembly-free, ultracompact system. IMPO is a self-contained blood pump and oxygenator assembly to enable rapid deployment for patients requiring respiratory support or circulatory support. In this study, computational fluid dynamics (CFD) and computer-aided design were conducted to design and optimize the hemodynamics, gas transfer, and hemocompatibility performances of this novel device. In parallel, in vitro experiments including hydrodynamic, gas transfer, and hemolysis measurements were conducted to evaluate the performance of IMPO. Computational results from CFD analysis were compared with experimental data collected from in vitro evaluation of the IMPO. The CFD simulation demonstrated a well-behaved and streamlined flow field in the main components of this device. The results of hydrodynamic performance, oxygen transfer, and hemolysis predicted by computational simulation, along with the in vitro experimental data, indicate that this pump-lung device can provide the total respiratory need of an adult with lung failure, with a low hemolysis rate at the targeted operating condition. These detailed CFD designs and analyses can provide valuable guidance for further optimization of this IMPO for long-term use.

  14. Cerebral activation of mitogen-activated protein kinases after circulatory arrest and low flow cardiopulmonary bypass.

    PubMed

    Aharon, Alon S; Mulloy, Matthew R; Drinkwater, Davis C; Lao, Oliver B; Johnson, Mahlon D; Thunder, Megan; Yu, Chang; Chang, Paul

    2004-11-01

    Mitogen-activated protein kinases (MAPK) are important intermediates in the signal transduction pathways involved in neuronal dysfunction following cerebral ischemia-reperfusion injury. One subfamily, extracellular regulated kinase 1/2, has been heavily implicated in the pathogenesis of post-ischemic neuronal damage. However, the contribution of extracellular regulated kinase 1/2 to neuronal damage following deep hypothermic circulatory arrest and low flow cardiopulmonary bypass is unknown. We attempted to correlate the extent of neuronal damage present following deep hypothermic circulatory arrest and low flow cardiopulmonary bypass with phosphorylated extracellular regulated kinase 1/2 expression in the cerebral vascular endothelium. Piglets underwent normal flow cardiopulmonary bypass (n=4) deep hypothermic circulatory arrest (n=6) and low flow cardiopulmonary bypass (n=5). Brains were harvested following 24 h of post-cardiopulmonary bypass recovery. Cerebral cortical watershed zones, hippocampus, basal ganglia, thalamus, cerebellum, mesencephalon, pons and medulla were evaluated using hematoxylin and eosin staining. A section of ischemic cortex was evaluated by immunohistochemistry with rabbit polyclonal antibodies against phosphorylated extracellular regulated kinase 1/2. Compared to cardiopulmonary bypass controls, the deep hypothermic circulatory arrest and low flow cardiopulmonary bypass piglets exhibited diffuse ischemic changes with overlapping severity and distribution. Significant neuronal damage occurred in the frontal watershed zones and basal ganglia of the deep hypothermic circulatory arrest group (P<0.05). No detectable phosphorylated extracellular regulated kinase 1/2 immunoreactivity was found in the cardiopulmonary bypass controls; however, ERK 1/2 immunoreactivity was present in the cerebral vascular endothelium of the deep hypothermic circulatory arrest and low flow cardiopulmonary bypass groups. Our results indicate that phosphorylated

  15. [Caffeine and adaptive changes in the circulatory system during pregnancy].

    PubMed

    Cendrowska-Pinkosz, Monika; Dworzański, Wojciech; Krauze, Magdalena; Burdan, Franciszek

    2017-01-23

    Adaptive physiological changes that occur in pregnant women can fluctuate with the intake of substances with proven, adverse biological effect on the body. Due to the fact that caffeine is one of the most chronically used xenobiotics, the impact of consuming caffeine on adaptive processes in the circulatory system of a pregnant women required a research. Many researchers emphasise its negative effect on the circulatory system of the mother and her offspring. However, in spite of years of observation, there is no clear answer to what extent dose or in what period of time the caffeine modulates the adaptive processes during pregnancy. Because of the potential risk the supply of caffeine during pregnancy should be subjected to considerable restrictions.

  16. User's instructions for the Guyton circulatory dynamics model using the Univac 1110 batch and demand processing (with graphic capabilities)

    NASA Technical Reports Server (NTRS)

    Archer, G. T.

    1974-01-01

    The model presents a systems analysis of a human circulatory regulation based almost entirely on experimental data and cumulative present knowledge of the many facets of the circulatory system. The model itself consists of eighteen different major systems that enter into circulatory control. These systems are grouped into sixteen distinct subprograms that are melded together to form the total model. The model develops circulatory and fluid regulation in a simultaneous manner. Thus, the effects of hormonal and autonomic control, electrolyte regulation, and excretory dynamics are all important and are all included in the model.

  17. Blood flow/pump rotation ratio as an artificial lung performance monitoring tool during extracorporeal respiratory support using centrifugal pumps

    PubMed Central

    Park, Marcelo; Mendes, Pedro Vitale; Hirota, Adriana Sayuri; dos Santos, Edzangela Vasconcelos; Costa, Eduardo Leite Vieira; Azevedo, Luciano Cesar Pontes

    2015-01-01

    Objective To analyze the correlations of the blood flow/pump rotation ratio and the transmembrane pressure, CO2 and O2 transfer during the extracorporeal respiratory support. Methods Five animals were instrumented and submitted to extracorporeal membrane oxygenation in a five-step protocol, including abdominal sepsis and lung injury. Results This study showed that blood flow/pump rotations ratio variations are dependent on extracorporeal membrane oxygenation blood flow in a positive logarithmic fashion. Blood flow/pump rotation ratio variations are negatively associated with transmembrane pressure (R2 = 0.5 for blood flow = 1500mL/minute and R2 = 0.4 for blood flow = 3500mL/minute, both with p < 0.001) and positively associated with CO2 transfer variations (R2 = 0.2 for sweep gas flow ≤ 6L/minute, p < 0.001, and R2 = 0.1 for sweep gas flow > 6L/minute, p = 0.006), and the blood flow/pump rotation ratio is not associated with O2 transfer variations (R2 = 0.01 for blood flow = 1500mL/minute, p = 0.19, and R2 = - 0.01 for blood flow = 3500 mL/minute, p = 0.46). Conclusion Blood flow/pump rotation ratio variation is negatively associated with transmembrane pressure and positively associated with CO2 transfer in this animal model. According to the clinical situation, a decrease in the blood flow/pump rotation ratio can indicate artificial lung dysfunction without the occurrence of hypoxemia. PMID:26340159

  18. Blood flow/pump rotation ratio as an artificial lung performance monitoring tool during extracorporeal respiratory support using centrifugal pumps.

    PubMed

    Park, Marcelo; Mendes, Pedro Vitale; Hirota, Adriana Sayuri; dos Santos, Edzangela Vasconcelos; Costa, Eduardo Leite Vieira; Azevedo, Luciano Cesar Pontes

    2015-01-01

    To analyze the correlations of the blood flow/pump rotation ratio and the transmembrane pressure, CO2 and O2 transfer during the extracorporeal respiratory support. Five animals were instrumented and submitted to extracorporeal membrane oxygenation in a five-step protocol, including abdominal sepsis and lung injury. This study showed that blood flow/pump rotations ratio variations are dependent on extracorporeal membrane oxygenation blood flow in a positive logarithmic fashion. Blood flow/pump rotation ratio variations are negatively associated with transmembrane pressure (R2 = 0.5 for blood flow = 1500mL/minute and R2 = 0.4 for blood flow = 3500mL/minute, both with p < 0.001) and positively associated with CO2 transfer variations (R2 = 0.2 for sweep gas flow ≤ 6L/minute, p < 0.001, and R2 = 0.1 for sweep gas flow > 6L/minute, p = 0.006), and the blood flow/pump rotation ratio is not associated with O2 transfer variations (R2 = 0.01 for blood flow = 1500mL/minute, p = 0.19, and R2 = - 0.01 for blood flow = 3500 mL/minute, p = 0.46). Blood flow/pump rotation ratio variation is negatively associated with transmembrane pressure and positively associated with CO2 transfer in this animal model. According to the clinical situation, a decrease in the blood flow/pump rotation ratio can indicate artificial lung dysfunction without the occurrence of hypoxemia.

  19. Two-Year Outcomes with a Magnetically Levitated Cardiac Pump in Heart Failure.

    PubMed

    Mehra, Mandeep R; Goldstein, Daniel J; Uriel, Nir; Cleveland, Joseph C; Yuzefpolskaya, Melana; Salerno, Christopher; Walsh, Mary N; Milano, Carmelo A; Patel, Chetan B; Ewald, Gregory A; Itoh, Akinobu; Dean, David; Krishnamoorthy, Arun; Cotts, William G; Tatooles, Antone J; Jorde, Ulrich P; Bruckner, Brian A; Estep, Jerry D; Jeevanandam, Valluvan; Sayer, Gabriel; Horstmanshof, Douglas; Long, James W; Gulati, Sanjeev; Skipper, Eric R; O'Connell, John B; Heatley, Gerald; Sood, Poornima; Naka, Yoshifumi

    2018-04-12

    In an early analysis of this trial, use of a magnetically levitated centrifugal continuous-flow circulatory pump was found to improve clinical outcomes, as compared with a mechanical-bearing axial continuous-flow pump, at 6 months in patients with advanced heart failure. In a randomized noninferiority and superiority trial, we compared the centrifugal-flow pump with the axial-flow pump in patients with advanced heart failure, irrespective of the intended goal of support (bridge to transplantation or destination therapy). The composite primary end point was survival at 2 years free of disabling stroke (with disabling stroke indicated by a modified Rankin score of >3; scores range from 0 to 6, with higher scores indicating more severe disability) or survival free of reoperation to replace or remove a malfunctioning device. The noninferiority margin for the risk difference (centrifugal-flow pump group minus axial-flow pump group) was -10 percentage points. Of 366 patients, 190 were assigned to the centrifugal-flow pump group and 176 to the axial-flow pump group. In the intention-to-treat population, the primary end point occurred in 151 patients (79.5%) in the centrifugal-flow pump group, as compared with 106 (60.2%) in the axial-flow pump group (absolute difference, 19.2 percentage points; 95% lower confidence boundary, 9.8 percentage points [P<0.001 for noninferiority]; hazard ratio, 0.46; 95% confidence interval [CI], 0.31 to 0.69 [P<0.001 for superiority]). Reoperation for pump malfunction was less frequent in the centrifugal-flow pump group than in the axial-flow pump group (3 patients [1.6%] vs. 30 patients [17.0%]; hazard ratio, 0.08; 95% CI, 0.03 to 0.27; P<0.001). The rates of death and disabling stroke were similar in the two groups, but the overall rate of stroke was lower in the centrifugal-flow pump group than in the axial-flow pump group (10.1% vs. 19.2%; hazard ratio, 0.47; 95% CI, 0.27 to 0.84, P=0.02). In patients with advanced heart failure, a fully

  20. Total heart replacement using dual intracorporeal continuous-flow pumps in a chronic bovine model: a feasibility study.

    PubMed

    Frazier, O H; Tuzun, Egemen; Cohn, William E; Conger, Jeffrey L; Kadipasaoglu, Kamuran A

    2006-01-01

    Continuous-flow pumps are small, simple, and respond physiologically to input variations, making them potentially ideal for total heart replacement. However, the physiological effects of complete pulseless flow during long-term circulatory support without a cardiac interface or with complete cardiac exclusion have not been well studied. We evaluated the feasibility of dual continuous-flow pumps as a total artificial heart (TAH) in a chronic bovine model. Both ventricles of a 6-month-old Corriente crossbred calf were excised and sewing rings attached to the reinforced atrioventricular junctions. The inlet portions of 2 Jarvik 2000 pumps were positioned through their respective sewing rings at the mid-atrial level and the pulseless atrial reservoir connected end-to-end to the pulmonary artery and aorta. Pulseless systemic and pulmonary circulations were thereby achieved. Volume status was controlled, and systemic and pulmonary resistance were managed pharmacologically to keep mean arterial pressures at 100+/-10 mmHg (systemic) and 20+/-5 mmHg (pulmonary) and both left and right atrial pressures at 15+/-5 mmHg. The left pump speed was maintained at 14,000 rpm and its output autoregulated in response to variations in right pump flow, systemic and pulmonary pressures, fluid status, and activity level. Hemodynamics, end-organ function, and neurohormonal status remained normal. These results suggest the feasibility of using dual continuous-flow pumps as a TAH.

  1. Abdominal tap

    MedlinePlus

    Peritoneal tap; Paracentesis; Ascites - abdominal tap; Cirrhosis - abdominal tap; Malignant ascites - abdominal tap ... abdominal cavity ( most often cancer of the ovaries ) Cirrhosis of the liver Damaged bowel Heart disease Infection ...

  2. Does the use of thiopental provide added cerebral protection during deep hypothermic circulatory arrest?

    PubMed Central

    Al-Hashimi, Sara; Zaman, Mahvash; Waterworth, Paul; Bilal, Haris

    2013-01-01

    A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was: Does the use of thiopental provide added cerebral protection during deep hypothermic circulatory arrest (DHCA)? Altogether, more than 62 papers were found using the reported search, of which 7 represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. Four of the seven papers used thiopental alongside other neuroprotective methods and agents. The methods included the use of ice packs to the head and core systemic hypothermia. Agents used alongside thiopental included nicardipine and mannitol. Thiopental was found to have the ability to lower oxygen consumption, where oxygen consumption was measured using the phosphocreatinine and adenosine triphosphate ratio. The neuroprotective effect of thiopental was evaluated by assessing the electrical activity of the brain during circulatory arrest, by which it was shown to be advantageous. However, other trials suggested that adding thiopental during circulatory arrest did not provide any extra protection to the brain. The timing of thiopental administration is of importance in order to gain positive outcomes, as it's ability to lower the cerebral energy state may result in unfavourable results if added before hypothermic circulatory arrest, where this may lead to an ischaemic event. We conclude that the use of thiopental during deep hypothermic circulatory arrest is beneficial, but if administered too early, it may replete the cerebral energy state before arrest and prove to be detrimental. PMID:23644730

  3. Does the use of thiopental provide added cerebral protection during deep hypothermic circulatory arrest?

    PubMed

    Al-Hashimi, Sara; Zaman, Mahvash; Waterworth, Paul; Bilal, Haris

    2013-08-01

    A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was: Does the use of thiopental provide added cerebral protection during deep hypothermic circulatory arrest (DHCA)? Altogether, more than 62 papers were found using the reported search, of which 7 represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. Four of the seven papers used thiopental alongside other neuroprotective methods and agents. The methods included the use of ice packs to the head and core systemic hypothermia. Agents used alongside thiopental included nicardipine and mannitol. Thiopental was found to have the ability to lower oxygen consumption, where oxygen consumption was measured using the phosphocreatinine and adenosine triphosphate ratio. The neuroprotective effect of thiopental was evaluated by assessing the electrical activity of the brain during circulatory arrest, by which it was shown to be advantageous. However, other trials suggested that adding thiopental during circulatory arrest did not provide any extra protection to the brain. The timing of thiopental administration is of importance in order to gain positive outcomes, as it's ability to lower the cerebral energy state may result in unfavourable results if added before hypothermic circulatory arrest, where this may lead to an ischaemic event. We conclude that the use of thiopental during deep hypothermic circulatory arrest is beneficial, but if administered too early, it may replete the cerebral energy state before arrest and prove to be detrimental.

  4. Computer Simulations of Valveless Pumping using the Immersed Boundary Method

    NASA Astrophysics Data System (ADS)

    Jung, Eunok; Peskin, Charles

    2000-03-01

    Pumping blood in one direction is the main function of the heart, and the heart is equipped with valves that ensure unidirectional flow. Is it possible, though, to pump blood without valves? This report is intended to show by numerical simulation the possibility of a net flow which is generated by a valveless mechanism in a circulatory system. Simulations of valveless pumping are motivated by biomedical applications: cardiopulmonary resuscitation (CPR); and the human foetus before the development of the heart valves. The numerical method used in this work is immersed boundary method, which is applicable to problems involving an elastic structure interacting with a viscous incompressible fluid. This method has already been applied to blood flow in the heart, platelet aggregation during blood clotting, aquatic animal locomotion, and flow in collapsible tubes. The direction of flow inside a loop of tubing which consists of (almost) rigid and flexible parts is investigated when the boundary of one end of the flexible segment is forced periodically in time. Despite the absence of valves, net flow around the loop may appear in these simulations. Furthermore, we present the new, unexpected results that the direction of this flow is determined not only by the position of the periodic compression, but also by the frequency and amplitude of the driving force.

  5. Staged abdominal re-operation for abdominal trauma.

    PubMed

    Taviloglu, Korhan

    2003-07-01

    To review the current developments in staged abdominal re-operation for abdominal trauma. To overview the steps of damage control laparotomy. The ever increasing importance of the resuscitation phase with current intensive care unit (ICU) support techniques should be emphasized. General surgeons should be familiar to staged abdominal re-operation for abdominal trauma and collaborate with ICU teams, interventional radiologists and several other specialties to overcome this entity.

  6. 76 FR 36548 - Circulatory System Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-22

    ...] Circulatory System Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY: Food and... of Committee: Circulatory System Devices Panel of the Medical Devices Advisory Committee. General... also comes with a sheath, introducer, loader, dilator, balloon (used to pre-dilate the native annulus...

  7. Reflex vascular responses to alterations in abdominal arterial pressure and flow in anaesthetized dogs.

    PubMed

    Drinkhill, M J; Doe, C P; Myers, D S; Self, D A; Hainsworth, R

    1997-11-01

    The existence of abdominal arterial baroreceptors has long been controversial. Previously difficulties have been encountered in localizing a stimulus to abdominal arteries without affecting reflexogenic areas elsewhere. In these experiments, using anaesthetized dogs, the abdomen was vascularly isolated at the level of the diaphragm, perfused through the aorta, and drained from the inferior vena cava to a reservoir. Changes in abdominal arterial pressure were effected by changing the perfusion pump speed. During this procedure the flow back to the animal from the venous outflow reservoir was held constant. Increases and decreases in abdominal arterial pressure resulted, respectively, in decreases and increases in perfusion pressure to a vascularly isolated hind-limb and in some dogs also a forelimb. Responses were significantly larger when carotid sinus pressure was high (120-180 mmHg) than when it was low (60 mmHg). Responses were still obtained after cutting vagus, phrenic and splanchnic nerves, but were abolished by spinal cord lesion at T12. These experiments provide evidence for the existence of abdominal arterial baroreceptors. The afferent pathway for the reflex vasodilatation appears to run in the spinal cord.

  8. The European Registry for Patients with Mechanical Circulatory Support (EUROMACS): first annual report.

    PubMed

    de By, Theo M M H; Mohacsi, Paul; Gummert, Jan; Bushnaq, Hasan; Krabatsch, Thomas; Gustafsson, Finn; Leprince, Pascal; Martinelli, Luigi; Meyns, Bart; Morshuis, Michiel; Netuka, Ivan; Potapov, Evgenij; Zittermann, Armin; Delmo Walter, Eva Maria; Hetzer, Roland

    2015-05-01

    The European Registry for Patients with Mechanical Circulatory Support (EUROMACS) was founded on 10 December 2009 with the initiative of Roland Hetzer (Deutsches Herzzentrum Berlin, Berlin, Germany) and Jan Gummert (Herz- und Diabeteszentrum Nordrhein-Westfalen, Bad Oeynhausen, Germany) with 15 other founding international members. It aims to promote scientific research to improve care of end-stage heart failure patients with ventricular assist device or a total artificial heart as long-term mechanical circulatory support. Likewise, the organization aims to provide and maintain a registry of device implantation data and long-term follow-up of patients with mechanical circulatory support. Hence, EUROMACS affiliated itself with Dendrite Clinical Systems Ltd to offer its members a software tool that allows input and analysis of patient clinical data on a daily basis. EUROMACS facilitates further scientific studies by offering research groups access to any available data wherein patients and centres are anonymized. Furthermore, EUROMACS aims to stimulate cooperation with clinical and research institutions and with peer associations involved to further its aims. EUROMACS is the only European-based Registry for Patients with Mechanical Circulatory Support with rapid increase in institutional and individual membership. Because of the expeditious data input, the European Association for Cardiothoracic Surgeons saw the need to optimize the data availability and the significance of the registry to improve care of patients with mechanical circulatory support and its potential contribution to scientific intents; hence, the beginning of their alliance in 2012. This first annual report is designed to provide an overview of EUROMACS' structure, its activities, a first data collection and an insight to its scientific contributions. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  9. 77 FR 25183 - Circulatory System Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-27

    ...] Circulatory System Devices Panel of the Medical Devices Advisory Committee; Notice of Meeting AGENCY: Food and... of Committee: Circulatory System Devices Panel of the Medical Devices Advisory Committee. General..., introducer, loader, dilator, balloon (used to pre-dilate the native annulus) and a crimper. FDA intends to...

  10. Early Identification of Circulatory Shock in Critical Care Transport

    DTIC Science & Technology

    2008-09-30

    disclosure and community consultation. Early Identification of Circulatory Shock in Critical Care Transport 2 Community consultation for this...in two aircraft types (Eurocopter EC 135 and EC 145), in IFR weather conditions, and during both day and night operations. We calculated the

  11. Superior cerebral protection with profound hypothermia during circulatory arrest.

    PubMed

    Gillinov, A M; Redmond, J M; Zehr, K J; Troncoso, J C; Arroyo, S; Lesser, R P; Lee, A W; Stuart, R S; Reitz, B A; Baumgartner, W A

    1993-06-01

    The optimal temperature for cerebral protection during hypothermic circulatory arrest is not known. This study was undertaken to test the hypothesis that deeper levels of cerebral hypothermia (< 10 degrees C) confer better protection against neurologic injury during prolonged hypothermic circulatory arrest ("colder is better"). Twelve male dogs (20 to 25 kg) were placed on closed-chest cardiopulmonary bypass via femoral artery and femoral/external jugular vein. Using surface and core cooling, tympanic membrane temperature was lowered to 18 degrees to 20 degrees C (deep hypothermia, n = 6) or 5 degrees to 7 degrees C (profound hypothermia, n = 6). After 2 hours of hypothermic circulatory arrest, animals were rewarmed to 35 degrees to 37 degrees C on cardiopulmonary bypass. All were mechanically ventilated and monitored in an intensive care unit setting for 20 hours. Neurologic assessment was performed every 12 hours using a species-specific behavior scale that yielded a neurodeficit score ranging from 0% to 100%, where 0 = normal and 100% = brain dead. After 72 hours, animals were sacrificed and examined histologically for neurologic injury. Histologic injury scores were assigned to each animal (range, 0 [normal] to 100 [severe injury]). At the end of the observation period, profoundly hypothermic animals had better neurologic function (neurodeficit score, 5.7% +/- 4.0%) compared with deeply hypothermic animals (neurodeficit score, 41% +/- 9.3%; p < 0.006). Every animal had histologic evidence of neurologic injury, but profoundly hypothermic animals had significantly less injury (histologic injury score, 19.2 +/- 1.2 versus 48.3 +/- 1.5; p < 0.0001).

  12. EXTRACORPOREAL MEMBRANE OXYGENATION vs. COUNTERPULSATILE, PULSATILE, AND CONTINUOUS LEFT VENTRICULAR UNLOADING FOR PEDIATRIC MECHANICAL CIRCULATORY SUPPORT

    PubMed Central

    Bartoli, Carlo R.; Koenig, Steven C.; Ionan, Constantine; Gillars, Kevin J.; Mitchell, Mike E.; Austin, Erle H.; Gray, Laman A.; Pantalos, George M.

    2014-01-01

    OBJECTIVE Despite progress with adult ventricular assist devices (VADs), limited options exist to support pediatric patients with life-threatening heart disease. Extracorporeal membrane oxygenation (ECMO) remains the clinical standard. To characterize (patho)physiologic responses to different modes of mechanical unloading of the failing pediatric heart, ECMO was compared to either intraaortic balloon pump (IABP), pulsatile-flow (PF)VAD, or continuous-flow (CF)VAD support in a pediatric heart failure model. DESIGN Experimental. SETTING Large animal laboratory operating room. SUBJECTS Yorkshire piglets (n=47, 11.7±2.6 kg). INTERVENTIONS In piglets with coronary ligation-induced cardiac dysfunction, mechanical circulatory support devices were implanted and studied during maximum support. MEASUREMENTS and MAIN RESULTS Left ventricular, right ventricular, coronary, carotid, systemic arterial, and pulmonary arterial hemodynamics were measured with pressure and flow transducers. Myocardial oxygen consumption and total-body oxygen consumption (VO2) were calculated from arterial, venous, and coronary sinus blood sampling. Blood flow was measured in 17 organs with microspheres. Paired student t-tests compared baseline and heart failure conditions. One-way repeated-measures ANOVA compared heart failure, device support mode(s), and ECMO. Statistically significant (p<0.05) findings included: 1) improved left ventricular blood supply/demand ratio during PFVAD, CFVAD, and ECMO but not IABP support, 2) improved global myocardial blood supply/demand ratio during PFVAD, and CFVAD but not IABP or ECMO support, and 3) diminished pulsatility during ECMO and CFVAD but not IABP and PFVAD support. A profile of systems-based responses was established for each type of support. CONCLUSIONS Each type of pediatric VAD provided hemodynamic support by unloading the heart with a different mechanism that created a unique profile of physiological changes. These data contribute novel, clinically

  13. Detection of circulatory microRNAs in prostate cancer.

    PubMed

    Srivastava, Anvesha; Goldberger, Helle; Afzal, Zainab; Suy, Simeng; Collins, Sean P; Kumar, Deepak

    2015-01-01

    Prostate cancer (PCa) is one of the most common cancer worldwide and accounts for 14.4 % of all new cancer cases. The clinical outcome and management of PCa can be significantly improved by use of biomarker assays for early detection, prognosis and also for prediction and monitoring of treatment response. MiRNAs are short, endogenous, single-stranded RNA molecules that play important role in regulation of gene expression and can modulate a number of cellular processes. Discovery of miRNAs in circulation has not only facilitated understanding their role in various diseases but also paved new avenues for biomarker discovery due to their ease of access and stability. The fact that a minimally invasive test based on miRNAs profiles can distinguish the presence or absence of disease illustrates immense potential of these molecules as predictive biomarkers.In this chapter, we have summarized the presumed mechanisms of miRNA release into the circulation and systematically summarized the studies of circulatory miRNAs in PCa. Also, we have mainly focused on the methodology of identification of circulatory miRNAs from biofluids.

  14. Devices as destination therapy.

    PubMed

    Kukuy, Eugene L; Oz, Mehmet C; Rose, Eric A; Naka, Yoshifumi

    2003-02-01

    The use of circulatory support as destination therapy has been a goal for the treatment of endstage heart failure for several decades. Current investigations are evaluating several circulatory pumps with that particular objective. With continued modification of design, the current and future pumps will become more reliable and provide improved quality of life to patients in need of mechanical circulatory assistance. The new pumps on the horizon specifically address reliability, size, and cost, and are based on the centrifugal system. These devices use the Maglev (Magnetic Levitation) concept that allows for frictionless pumping, low thrombogenicity, minimal noise, and increased durability. Further research with this goal in mind and support from the federal government will be the key to the future use of circulatory assistance as destination therapy for heart failure patients. In addition, the cost-effectiveness of these devices will need to be maintained as the technology improves, as in any new technology that confronts a more intuitive option like the native heart.

  15. Effect of a bearing gap on hemolytic property in a hydrodynamically levitated centrifugal blood pump with a semi-open impeller.

    PubMed

    Kosaka, Ryo; Nishida, Masahiro; Maruyama, Osamu; Yambe, Tomoyuki; Imachi, Kou; Yamane, Takashi

    2013-01-01

    We have developed a hydrodynamically levitated centrifugal blood pump with a semi-open impeller for long-term circulatory assist. The pump uses hydrodynamic bearings to enhance durability and reliability without additional displacement-sensors or control circuits. However, a narrow bearing gap of the pump has a potential for hemolysis. The purpose of this study is to develop the hydrodynamically levitated centrifugal blood pump with a semi-open impeller, and to evaluate the effect of a bearing gap on hemolytic property. The impeller levitates using a spiral-groove type thrust bearing, and a herringbone-groove type radial bearing. The pump design was improved by adopting a step type thrust bearing and optimizing the pull-up magnetic force. The pump performance was evaluated by a levitation performance test, a hemolysis test and an animal experiment. In these tests, the bearing gap increased from 1 to 63 μm. In addition, the normalized index of hemolysis (NIH) improved from 0.415 to 0.005 g/100 l, corresponding to the expansion of the bearing gap. In the animal experiment for 24 h, the plasma-free hemoglobin remained within normal ranges (<4.0 mg/dl). We confirmed that the hemolytic property of the pump was improved to the acceptable level by expanding the bearing gap greater than 60 μm.

  16. Improvement of hemocompatibility in centrifugal blood pump with hydrodynamic bearings and semi-open impeller: in vitro evaluation.

    PubMed

    Kosaka, Ryo; Maruyama, Osamu; Nishida, Masahiro; Yada, Toru; Saito, Sakae; Hirai, Shusaku; Yamane, Takashi

    2009-10-01

    We have developed a noncontact-type centrifugal blood pump with hydrodynamic bearings and a semi-open impeller for mechanical circulatory assist. The impeller is levitated by an original spiral-groove thrust bearing and a herringbone-groove journal bearing, without any additional displacement-sensing module or additional complex control circuits. The pump was improved by optimizing the groove direction of the spiral-groove thrust bearing and the pull-up magnetic force between the rotor magnet and the stator coil against the impeller. To evaluate hemocompatibility, we conducted a levitation performance test and in vitro hemocompatibility tests by means of a mock-up circulation loop. In the hemolysis test, the normalized index of hemolysis was reduced from 0.721 to 0.0335 g/100 L corresponding to an expansion of the bearing gap from 1.1 to 56.1 microm. In the in vitro antithrombogenic test, blood pumps with a wide thrust bearing gap were effective in preventing thrombus formation. Through in vitro evaluation tests, we confirmed that hemocompatibility was improved by balancing the hydrodynamic fluid dynamics and magnetic forces.

  17. Health care utilization and costs for diseases of the circulatory system in a corporate setting.

    PubMed

    Tsai, S P; Bernacki, E J; Reedy, S M; Miller, K E

    1988-01-01

    This article presents the health care utilization and costs for diseases of the circulatory system among 14,162 employees and their spouses based on medical insurance claims data analysis. Diseases of the circulatory system ranked first among insurance claims and costs accounting for 23% ($4.6 million) of the plan's total health care costs ($19.7 million) for the 1984 policy year. Overall, 57% of these expenditures were for hospital care, the proportion for hospital costs being as high as 64% for heart diseases and as low as 20% for hypertension. Male employees had higher utilization for both in-hospital and out-patient services than females. Utilization rates and costs dramatically increased for individuals 50 years or older. Costs for surgical and diagnostic procedures amounted to 8% of the total costs of circulatory system disorders. This article provides an example of the utility of claims analysis for morbidity surveillance. The analyses and parameters measured herein can be viewed as prerequisites to the development of health care management and health promotion strategies aimed at reducing health care cost for diseases of the circulatory system in a corporate setting.

  18. The OregonHeart Total Artificial Heart: Design and Performance on a Mock Circulatory Loop.

    PubMed

    Glynn, Jeremy; Song, Howard; Hull, Bryan; Withers, Stanley; Gelow, Jill; Mudd, James; Starr, Albert; Wampler, Richard

    2017-10-01

    Widespread use of heart transplantation is limited by the scarcity of donor organs. Total artificial heart (TAH) development has been pursued to address this shortage, especially to treat patients who require biventricular support. We have developed a novel TAH that utilizes a continuously spinning rotor that shuttles between two positions to provide pulsatile, alternating blood flow to the systemic and pulmonary circulations without artificial valves. Flow rates and pressures generated by the TAH are controlled by adjusting rotor speed, cycle frequency, and the proportion of each cycle spent pumping to either circulation. To validate the design, a TAH prototype was placed in a mock circulatory loop that simulates vascular resistance, pressure, and compliance in normal and pathophysiologic conditions. At a systemic blood pressure of 120/80 mm Hg, nominal TAH output was 7.4 L/min with instantaneous flows reaching 17 L/min. Pulmonary artery, and left and right atrial pressures were all maintained within normal ranges. To simulate implant into a patient with severe pulmonary hypertension, the pulmonary vascular resistance of the mock loop was increased to 7.5 Wood units. By increasing pump speed to the pulmonary circulation, cardiac output could be maintained at 7.4 L/min as mean pulmonary artery pressure increased to 56 mm Hg while systemic blood pressures remained normal. This in vitro testing of a novel, shuttling TAH demonstrated that cardiac output could be maintained across a range of pathophysiologic conditions including pulmonary hypertension. These experiments serve as a proof-of-concept for the design, which has proceeded to in vivo testing. © 2017 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  19. Leg ischaemia before circulatory arrest alters brain leucocyte count and respiratory chain redox state.

    PubMed

    Yannopoulos, Fredrik S; Arvola, Oiva; Haapanen, Henri; Herajärvi, Johanna; Miinalainen, Ilkka; Jensen, Hanna; Kiviluoma, Kai; Juvonen, Tatu

    2014-03-01

    Remote ischaemic preconditioning and its neuroprotective abilities are currently under investigation and the method has shown significant effects in several small and large animal studies. In our previous studies, leucocyte filtration during cardiopulmonary bypass reduced cerebrocortical adherent leucocyte count and mitigated cerebral damage after hypothermic circulatory arrest (HCA) in piglets. This study aimed to obtain and assess direct visual data of leucocyte behaviour in cerebral vessels after hypothermic circulatory arrest following remote ischaemic preconditioning. Twelve native stock piglets were randomized into a remote ischaemic preconditioning group (n = 6) and a control group (n = 6). The intervention group underwent hind-leg ischaemia, whereas the control group received a sham-treatment before a 60-min period of hypothermic circulatory arrest. An intravital microscope was used to obtain measurements from the cerebrocortical vessel in vivo. It included three sets of filters: a violet filter to visualize microvascular perfusion and vessel diameter, a green filter for visualization of rhodamine-labelled leucocytes and an ultraviolet filter for reduced nicotinamide adenine dinucleotide (NADH) analysis. The final magnification on the microscope was 400. After the experiment, cerebral and cerebellar biopsies were collected and analysed with transmission electron microscope by a blinded analyst. In the transmission electron microscope analysis, the entire intervention group had normal, unaffected rough endoplasmic reticulum's in their cerebellar tissue, whereas the control group had a mean score of 1.06 (standard deviation 0.41) (P = 0.026). The measured amount of adherent leucocytes was lower in the remote ischaemic preconditioning group. The difference was statistically significant at 5, 15 and 45 min after circulatory arrest. Statistically significant differences were seen also in the recovery phase at 90 and 120 min after reperfusion. Nicotinamide

  20. A 12 year prospective study of circulatory disease among Danish shift workers.

    PubMed

    Tüchsen, F; Hannerz, H; Burr, H

    2006-07-01

    Previous studies of the risk of heart disease after shift work reached different estimates and review authors disagree about the validity of some of the studies. A cross sectional study showed that shift workers had a higher prevalence of nearly every unfavourable work environment factor investigated. Conflicts at work and low decision latitude were more frequent among shift workers, and all-day walking or standing work and part-time jobs were more often found among female shift workers. To estimate the risk of circulatory disease in a prospective follow up of a representative sample of gainfully employed Danes, considering known or suspected confounding factors. A cohort of 5517 people who were gainfully employed in 1990 were followed up for all hospital treatments due to circulatory diseases (390-458, ICD-8; I00-I99, ICD-10) from 1991 to 2002 inclusive. A log linear Poisson regression model was applied to control confounding factors and calculate the relative risk for 927 men and women working nights, evenings, or other non-day shifts compared to 4579 day workers. Non-day workers compared to day workers had a relative risk (RR) for all circulatory diseases of 1.31 (95% CI 1.06-1.63). Without control for BMI and smoking, the RR estimate was 1.33 (95% CI 1.07-1.65). For a subgroup of workers with at least three years' seniority, the RR was 1.40 (95% CI 1.09-1.81). The population based aetiological fraction of shift work was estimated to 5%. This study adds to a growing body of evidence suggesting that shift work carries an excess risk of circulatory diseases.

  1. Efficacy of a new intraaortic propeller pump vs the intraaortic balloon pump: an animal study.

    PubMed

    Dekker, André; Reesink, Koen; van der Veen, Erik; Van Ommen, Vincent; Geskes, Gijs; Soemers, Cecile; Maessen, Jos

    2003-06-01

    To compare the efficacy of a new intraaortic propeller pump (PP) to provide hemodynamic support to the intraaortic balloon pump (IABP) in an acute mitral regurgitation (MR) animal model. A new intraaortic PP (Reitan catheter pump; Jomed; Helsingborg, Sweden) recently has been introduced. The pump's aim is a reduction in afterload via a deployable propeller that is placed in the high descending aorta and can be set at rotational speeds of abdominal aortic pressure, left atrial pressure, and LV pressure-volume loops were recorded. The PP caused an rpm-dependent reduction in the mean ascending aortic pressure reaching -10 mm Hg (p < 0.05) at 14,000 rpm. However, mean (+/- SD) cardiac output did not improve (2.6 +/- 0.7 to 2.5 +/- 1.1 L/min; p = not significant), and mean diastolic coronary flow and carotid flow (47 +/- 16 to 35 +/- 15 centiliters/min, p < 0.05) were reduced. The IABP improved cardiac output, and carotid and diastolic coronary flow. In this acute MR animal model, the PP reduced afterload but left out positive effects on cardiac output, which resulted in reduced perfusion of the upper body and the coronary circulation. Therefore, the IABP gives better hemodynamic support than the new PP in calves with acute MR.

  2. [The disease burden of cardiovascular and circulatory diseases in China, 1990 and 2010].

    PubMed

    Liu, Jiangmei; Liu, Yunning; Wang, Lijun; Yin, Peng; Liu, Shiwei; You, Jinling; Zeng, Xinying; Zhou, Maigeng

    2015-04-01

    To analyze the death status of disease burden of cardiovascular and circulatory diseases in 1990 and 2010 in China, and to provide the basic information for cardiovascular and circulatory disease prevention and control. Using the results of the Global Burden of Diseases Study 2010 (GBD 2010) to describe the cardiovascular and circulatory diseases deaths status and disease burden in China. The measurement index included the mortality, years of life lost due to premature mortality (YLL), years lived with disability (YLD), and disability-adjusted life years (DALY). At the same time, we used the population from 2010 national census as standard population to calculate the age-standardized mortality rate and DALY rate, YLL rate and YLD rates which will describe the mortality status and disease burden of total and different types of cardiovascular disease. We also calculated the change in 1990 and 2010 for all indexes, to describe the change of the burden of disease in the 20 years. In 2010, the total deaths of cardiovascular and circulatory diseases reached 3.136 2 million, the mortality rate reached 233.70 per 100 000 people and the age-standardized mortality rate was 256.90 per 100 000 people. The total DALYs, YLLs, and YLDs of cardiovascular and circulatory diseases reached 58.2055, 54.0488, and 4.1568 million person-years, respectively, and the age-standardized DALY rate, YLL rate and YLD rate were 4 639.04, 4 313.13, 325.91 per 100 000. In 1990, the deaths only 2.1675 million and the DALYs, YLLs and YLDs were 45.2679, 42.2922, and 2.9757 million person-years. The age-standardized mortality rate was 300.30 per 100 000 people. And the age-standardized DALY rate, YLL rate and YLD rate were 5 872.58, 5 523.42 and 349.16 per 100 000. Compared with the result in 1990, the total deaths, DALYs, YLLs, and YLDs were increased 44.72%, 28.58%, 27.80%, and 39.68%, respectively, while the age-standardized mortality rate, age-standardized DALY rate, age-standardized YLL rate, and

  3. Afterload-dependent flow fluctuation of centrifugal pump: should it be actively fixed?

    PubMed

    Nishida, H; Akazawa, T; Nishinaka, T; Aomi, S; Endo, M; Koyanagi, H

    1998-05-01

    To evaluate the clinical meaning and effects of afterload-dependent flow fluctuation in a centrifugal pump, concomitant measurement of flow rate and mixed venous oxygen saturation (SVO2) was performed in 5 cases of open heart surgery in which the patients underwent cardiopulmonary bypass (CPB) with the Terumo Capiox centrifugal pump. Continuous measurement of SVO2 using the 3M CDI System 100 was performed with a disposable cuvette incorporated into the drainage circuit. After the target flow rate of 2.4 L/min/m2 was obtained under a nonbeating condition, the pump rotational speed was fixed. During the cooling and low temperature period, SVO2 decreased as the flow rate spontaneously decreased but still stayed around 80% even with a 15-20% decrease in blood flow rate. This indicates that a luxury perfusion condition is ensured as long as the body temperature is kept low. In contrast, during the rewarming period, SVO2 decreased to around 70-75% despite a 15-25% spontaneous increase in flow rate. Although this level of SVO2 still indicates adequate systemic perfusion, there is a possibility of regional hypoperfusion in patients with such conditions as cerebrovascular disease. In conclusion, although diligent adjustment of the physiological fluctuating flow rate in the centrifugal pump seems unnecessary during conventional open heart surgery, manual control may be necessary especially during the rewarming period, normothermic surgery, or circulatory assist for shocked patients. From this study, we also conclude that the major benefit of the afterload-independent autoflow control system of the centrifugal pump is the improvement of safety in terms of the fixed reservoir level and the handling of cardiopulmonary bypass.

  4. Feasibility of the optical imaging of thrombus formation in a rotary blood pump by near-infrared light.

    PubMed

    Sakota, Daisuke; Murashige, Tomotaka; Kosaka, Ryo; Nishida, Masahiro; Maruyama, Osamu

    2014-09-01

    Blood coagulation is one of the primary concerns when using mechanical circulatory support devices such as blood pumps. Noninvasive detection and imaging of thrombus formation is useful not only for the development of more hemocompatible devices but also for the management of blood coagulation to avoid risk of infarction. The objective of this study is to investigate the use of near-infrared light for imaging of thrombus formation in a rotary blood pump. The optical properties of a thrombus at wavelengths ranging from 600 to 750 nm were analyzed using a hyperspectral imaging (HSI) system. A specially designed hydrodynamically levitated centrifugal blood pump with a visible bottom area was used. In vitro antithrombogenic testing was conducted five times with the pump using bovine whole blood in which the activated blood clotting time was adjusted to 200 s prior to the experiment. Two halogen lights were used for the light sources. The forward scattering through the pump and backward scattering on the pump bottom area were imaged using the HSI system. HSI showed an increase in forward scattering at wavelengths ranging from 670 to 750 nm in the location of thrombus formation. The time at which the thrombus began to form in the impeller rotating at 2780 rpm could be detected. The spectral difference between the whole blood and the thrombus was utilized to image thrombus formation. The results indicate the feasibility of dynamically detecting and imaging thrombus formation in a rotary blood pump. Copyright © 2014 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  5. Practice pattern and professional issues of nurse practitioners in mechanical circulatory support programs in the United States: a survey report.

    PubMed

    Casida, Jesus M; Pastor, Jessica

    2012-09-01

    Few data-based reports about the role and work environment of advanced practice nurses, specifically nurse practitioners in mechanical circulatory support programs, have been published. To describe the practice pattern and professional issues confronted by nurse practitioners in the rapidly evolving and expanding mechanical circulatory support programs in the United States. A descriptive research design was employed using the data from the 2010 mechanical circulatory support nurses survey. Quantitative and qualitative data that pertained to the demographic and practice profiles as well as barriers and overall issues faced by the nurse practitioners in their clinical practice were analyzed. Nonrandom sample of 48 nurse practitioners from 95 mechanical circulatory support programs nationwide. The practice pattern of nurse practitioners in mechanical circulatory support programs is similar to the practice pattern reported for nurse practitioners in acute and critical care settings. However, only 44% and 10% of nurse practitioners in mechanical circulatory support programs are authorized to admit and transfer patients into and out of the hospital, respectively. High workload, lack of institutional support, knowledge deficit, role ambiguity, lack of professional recognition, and burnout were the common issues faced by the participants in their clinical practice. The results provide preliminary evidence on the practice pattern, restrictions, and work environment issues that may threaten the viability of an mechanical circulatory support program in which nurse practitioners play a crucial role. Implications for clinical practice, research, and policy development are discussed.

  6. Mechanical performance comparison between RotaFlow and CentriMag centrifugal blood pumps in an adult ECLS model.

    PubMed

    Yulong Guan; Xiaowei Su; McCoach, Robert; Kunselman, Allen; El-Banayosy, Aly; Undar, Akif

    2010-03-01

    Centrifugal blood pumps have been widely adopted in conventional adult cardiopulmonary bypass and circulatory assist procedures. Different brands of centrifugal blood pumps incorporate distinct designs which affect pump performance. In this adult extracorporeal life support (ECLS) model, the performances of two brands of centrifugal blood pump (RotaFlow blood pump and CentriMag blood pump) were compared. The simulated adult ECLS circuit used in this study included a centrifugal blood pump, Quadrox D membrane oxygenator and Sorin adult ECLS tubing package. A Sorin Cardiovascular(R) VVR(R) 4000i venous reservoir (Sorin S.p.A., Milan, Italy) with a Hoffman clamp served as a pseudo-patient. The circuit was primed with 900ml heparinized human packed red blood cells and 300ml lactated Ringer's solution (total volume 1200 ml, corrected hematocrit 40%). Trials were conducted at normothermia (36 degrees C). Performance, including circuit pressure and flow rate, was measured for every setting analyzed. The shut-off pressure of the RotaFlow was higher than the CentriMag at all measurement points given the same rotation speed (p < 0.0001). The shut-off pressure differential between the two centrifugal blood pumps was significant and increased given higher rotation speeds (p < 0.0001). The RotaFlow blood pump has higher maximal flow rate (9.08 +/- 0.01L/min) compared with the CentriMag blood pump (8.37 +/- 0.02L/min) (p < 0.0001). The blood flow rate differential between the two pumps when measured at the same revolutions per minute (RPM) ranged from 1.64L/min to 1.73L/min. The results obtained in this experiment demonstrate that the RotaFlow has a higher shut-off pressure (less retrograde flow) and maximal blood flow rate than the CentriMag blood pump. Findings support the conclusion that the RotaFlow disposable pump head has a better mechanical performance than the CentriMag. In addition, the RotaFlow disposable pump is 20-30 times less expensive than the CentriMag.

  7. [Abdominal trauma].

    PubMed

    Sido, B; Grenacher, L; Friess, H; Büchler, M W

    2005-09-01

    Blunt abdominal trauma is much more frequent than penetrating abdominal trauma in Europe. As a consequence of improved quality of computed tomography, even complex liver injuries are increasingly being treated conservatively. However, missed hollow viscus injuries still remain a problem, as they considerably increase mortality in multiply injured patients. Laparoscopy decreases the rate of unnecessary laparotomies in perforating abdominal trauma and helps to diagnose injuries of solid organs and the diaphragm. However, the sensitivity in detecting hollow viscus injuries is low and the role of laparoscopy in blunt abdominal injury has not been defined. If intra-abdominal bleeding is difficult to control in hemodynamically unstable patients, damage control surgery with packing of the liver, total splenectomy, and provisional closure of hollow viscus injuries is of importance. Definitive surgical treatment follows hemodynamic stabilization and restoration of hemostasis. Injuries of the duodenum and pancreas after blunt abdominal trauma are often associated with other intra-abdominal injuries and the treatment depends on their location and severity.

  8. The physiology of dinosaurs: circulatory and respiratory function in the largest animals ever to walk the earth.

    PubMed

    Pierson, David J

    2009-07-01

    The cardiopulmonary physiology of dinosaurs-and especially of the long-necked sauropods, which grew much larger than any land animals before or since-should be inherently fascinating to anyone involved in respiratory care. What would the blood pressure be in an animal 12 m (40 ft) tall? How could airway resistance and dead space be overcome while breathing through a trachea 9 m (30 ft) long? The last decade has seen a dramatic increase in evidence bearing on these questions. Insight has come not only from new fossil discoveries but also from comparative studies of living species, clarification of evolutionary relationships, new evaluation techniques, computer modeling, and discoveries about the earth's ancient atmosphere. Pumping a vertical column of blood 8 m (26 ft) above the heart would probably require an arterial blood pressure > 600 mm Hg, and the implications of this for cardiac size and function have led to the proposal of several alternative cardiopulmonary designs. Diverse lines of evidence suggest that the giant sauropods were probably warm-blooded and metabolically active when young, but slowed their metabolism as they approached adult size, which diminished the load on the circulatory system. Circulatory considerations leave little doubt that the dinosaurs had 4-chambered hearts. Birds evolved from dinosaurs, and the avian-type air-sac respiratory system, which is more efficient than its mammalian counterpart, may hold the answer to the breathing problems posed by the sauropods' very long necks. Geochemical and other data indicate that, at the time the dinosaurs first appeared, the atmospheric oxygen concentration was only about half of what it is today, and development of the avian-type respiratory system may have been key in the dinosaurs' evolutionary success, enabling them to out-compete the mammals and dominate the land for 150 million years.

  9. Effects of intra-aortic balloon pump versus centrifugal pump on myocardial energetics and systemic circulation in a porcine model of rapidly worsening acute heart failure.

    PubMed

    Ntalianis, Argyrios S; Drakos, Stavros G; Charitos, Christos; Dolou, Paraskevi; Pierrakos, Charalampos N; Terrovitis, John V; Papaioannou, Theodoros; Charitos, Efstratios; Nanas, John N

    2008-01-01

    The present experimental study compared the effectiveness of counterpulsation provided by the intra-aortic balloon pump (IABP) versus that of a nonpulsatile, radial-flow centrifugal pump (CFP) in rapidly worsening acute heart failure (HF). Eighteen pigs were included in the study. After the induction of acute moderate HF, circulatory support was randomly provided with either the IABP or CFP. No significant change in cardiac output (CO) and mean aortic pressure (MAP) was observed with either pump. The IABP caused a significantly greater decrease than the CFP in 1) double product (13.138 +/- 2.476 mm Hg/min vs. 14.217 +/- 2.673 mm Hg/min, p = 0.023), 2) left ventricular systolic pressure (LVSP, 100 +/- 8 mm Hg vs. 106 +/- 10 mm Hg, p = 0.046), and 3) end-diastolic aortic pressure (EDAP, 70 +/- 6 mm Hg vs. 86 +/- 6 mm Hg, p = 0.000). The effects of both pumps on total tension time index and LAD flow were similar. After the induction of severe HF, the IABP had its main effects on afterload and decreased LVSP from 88 +/- 6 mm Hg to 78 +/- 9 mm Hg, (p = 0.008), and EDAP from 57 +/- 9 mm Hg to 49 +/- 14 mm Hg, (p = 0.044), whereas the CFP exerted its effects mainly on preload, lowering LV end-diastolic pressure from 19 +/- 5 mm Hg to 11 +/- 4 mm Hg, (p = 0.002). CO and MAP were similarly increased by both assist systems. The IABP (by lowering afterload) and CFP (by lowering preload) both offered significant mechanical support in acute HF. However, afterload reduction offered principally by the IABP seems preferable for the recovery of the acutely failing heart.

  10. Advancements in mechanical circulatory support for patients in acute and chronic heart failure

    PubMed Central

    Csepe, Thomas A.

    2017-01-01

    Cardiogenic shock (CS) continues to have high mortality and morbidity despite advances in pharmacological, mechanical, and reperfusion approaches to treatment. When CS is refractory to medical therapy, percutaneous mechanical circulatory support (MCS) should be considered. Acute MCS devices, ranging from intra-aortic balloon pumps (IABPs) to percutaneous temporary ventricular assist devices (VAD) to extracorporeal membrane oxygenation (ECMO), can aid, restore, or maintain appropriate tissue perfusion before the development of irreversible end-organ damage. Technology has improved patient survival to recovery from CS, but in patients whom cardiac recovery does not occur, acute MCS can be effectively utilized as a bridge to long-term MCS devices and/or heart transplantation. Heart transplantation has been limited by donor heart availability, leading to a greater role of left ventricular assist device (LVAD) support. In patients with biventricular failure that are ineligible for LVAD implantation, further advancements in the total artificial heart (TAH) may allow for improved survival compared to medical therapy alone. In this review, we discuss the current state of acute and durable MCS, ongoing advances in LVADs and TAH devices, improved methods of durable MCS implantation and patient selection, and future MCS developments in this dynamic field that may allow for optimization of HF treatment. PMID:29268418

  11. Muscle powered blood pump: design and initial test results.

    PubMed

    Trumble, D R; Magovern, J A

    1999-01-01

    A pneumatic ventricular assist device (Sarns/3M) has been redesigned for low volume hydraulic actuation to accommodate muscle powered drive systems. Design modifications include adding a bellows/piston mechanism (to compress the blood sac) and a compliance chamber for volume compensation. A simple prototype device was constructed to measure the efficacy of piston pump actuation and to validate pusher plate design. Device manufacture was affected by removing the drive line housing from the pneumatic pump and replacing it with a piston/bushing mechanism. A convex piston profile was chosen to maximize ejection fraction and minimize device size. Stroke volume was found to be a linear function of piston displacement (approximately 3 ml/mm) and reached a maximum value of 45 ml. Mean compression forces of 46-56 N acting during a 12 mm stroke (2.1 L/min at 60 cycles/min) were sufficient to generate mean afterload pressures of 70-110 mm Hg in a mock circulatory loop. Peak compression forces ranged from 72 to 86 N and work input was calculated to be 552-672 mJ/stroke. These data indicate that this method for delivering muscle power to the bloodstream is both mechanically viable and compatible with the functional capacity of conditioned latissimus dorsi muscle.

  12. On the Mechanism of Human Red Blood Cell Longevity: Roles of Calcium, the Sodium Pump, PIEZO1, and Gardos Channels.

    PubMed

    Lew, Virgilio L; Tiffert, Teresa

    2017-01-01

    In a healthy adult, the transport of O 2 and CO 2 between lungs and tissues is performed by about 2 · 10 13 red blood cells, of which around 1.7 · 10 11 are renewed every day, a turnover resulting from an average circulatory lifespan of about 120 days. Cellular lifespan is the result of an evolutionary balance between the energy costs of maintaining cells in a fit functional state versus cell renewal. In this Review we examine how the set of passive and active membrane transporters of the mature red blood cells interact to maximize their circulatory longevity thus minimizing costs on expensive cell turnover. Red blood cell deformability is critical for optimal rheology and gas exchange functionality during capillary flow, best fulfilled when the volume of each human red blood cell is kept at a fraction of about 0.55-0.60 of the maximal spherical volume allowed by its membrane area, the optimal-volume-ratio range. The extent to which red blood cell volumes can be preserved within or near these narrow optimal-volume-ratio margins determines the potential for circulatory longevity. We show that the low cation permeability of red blood cells allows volume stability to be achieved with extraordinary cost-efficiency, favouring cell longevity over cell turnover. We suggest a mechanism by which the interplay of a declining sodium pump and two passive membrane transporters, the mechanosensitive PIEZO1 channel, a candidate mediator of P sickle in sickle cells, and the Ca 2+ -sensitive, K + -selective Gardos channel, can implement red blood cell volume stability around the optimal-volume-ratio range, as required for extended circulatory longevity.

  13. On the Mechanism of Human Red Blood Cell Longevity: Roles of Calcium, the Sodium Pump, PIEZO1, and Gardos Channels

    PubMed Central

    Lew, Virgilio L.; Tiffert, Teresa

    2017-01-01

    In a healthy adult, the transport of O2 and CO2 between lungs and tissues is performed by about 2 · 1013 red blood cells, of which around 1.7 · 1011 are renewed every day, a turnover resulting from an average circulatory lifespan of about 120 days. Cellular lifespan is the result of an evolutionary balance between the energy costs of maintaining cells in a fit functional state versus cell renewal. In this Review we examine how the set of passive and active membrane transporters of the mature red blood cells interact to maximize their circulatory longevity thus minimizing costs on expensive cell turnover. Red blood cell deformability is critical for optimal rheology and gas exchange functionality during capillary flow, best fulfilled when the volume of each human red blood cell is kept at a fraction of about 0.55–0.60 of the maximal spherical volume allowed by its membrane area, the optimal-volume-ratio range. The extent to which red blood cell volumes can be preserved within or near these narrow optimal-volume-ratio margins determines the potential for circulatory longevity. We show that the low cation permeability of red blood cells allows volume stability to be achieved with extraordinary cost-efficiency, favouring cell longevity over cell turnover. We suggest a mechanism by which the interplay of a declining sodium pump and two passive membrane transporters, the mechanosensitive PIEZO1 channel, a candidate mediator of Psickle in sickle cells, and the Ca2+-sensitive, K+-selective Gardos channel, can implement red blood cell volume stability around the optimal-volume-ratio range, as required for extended circulatory longevity. PMID:29311949

  14. Chronic abdominal wall pain misdiagnosed as functional abdominal pain.

    PubMed

    van Assen, Tijmen; de Jager-Kievit, Jenneke W A J; Scheltinga, Marc R; Roumen, Rudi M H

    2013-01-01

    The abdominal wall is often neglected as a cause of chronic abdominal pain. The aim of this study was to identify chronic abdominal wall pain syndromes, such as anterior cutaneous nerve entrapment syndrome (ACNES), in a patient population diagnosed with functional abdominal pain, including irritable bowel syndrome, using a validated 18-item questionnaire as an identification tool. In this cross-sectional analysis, 4 Dutch primary care practices employing physicians who were unaware of the existence of ACNES were selected. A total of 535 patients ≥18 years old who were registered with a functional abdominal pain diagnosis were approached when they were symptomatic to complete the questionnaire (maximum 18 points). Responders who scored at least the 10-point cutoff value (sensitivity, 0.94; specificity, 0.92) underwent a diagnostic evaluation to establish their final diagnosis. The main outcome was the presence and prevalence of ACNES in a group of symptomatic patients diagnosed with functional abdominal pain. Of 535 patients, 304 (57%) responded; 167 subjects (31%) recently reporting symptoms completed the questionnaire. Of 23 patients who scored above the 10-point cutoff value, 18 were available for a diagnostic evaluation. In half of these subjects (n = 9) functional abdominal pain (including IBS) was confirmed. However, the other 9 patients were suffering from abdominal wall pain syndrome, 6 of whom were diagnosed with ACNES (3.6% prevalence rate of symptomatic subjects; 95% confidence interval, 1.7-7.6), whereas the remaining 3 harbored a painful lipoma, an abdominal herniation, and a painful scar. A clinically relevant portion of patients previously diagnosed with functional abdominal pain syndrome in a primary care environment suffers from an abdominal wall pain syndrome such as ACNES.

  15. Evaluation of erythrocyte flow at a bearing gap in a hydrodynamically levitated centrifugal blood pump.

    PubMed

    Murashige, Tomotaka; Kosaka, Ryo; Sakota, Daisuke; Nishida, Masahiro; Kawaguchi, Yasuo; Yamane, Takashi; Maruyama, Osamu

    2015-01-01

    We have developed a hydrodynamically levitated centrifugal blood pump for extracorporeal circulatory support. In the blood pump, a spiral groove bearing was adopted for a thrust bearing. In the spiral groove bearing, separation of erythrocytes and plasma by plasma skimming has been postulated to occur. However, it is not clarified that plasma skimming occurs in a spiral groove bearing. The purpose of this study is to verify whether plasma skimming occurs in the spiral groove bearing of a hydrodynamically levitated centrifugal blood pump. For evaluation of plasma skimming in the spiral groove bearing, an impeller levitation performance test using a laser focus displacement meter and a microscopic visualization test of erythrocyte flow using a high-speed microscope were conducted. Bovine blood diluted with autologous plasma to adjust hematocrit to 1.0% was used as a working fluid. Hematocrit on the ridge region in the spiral groove bearing was estimated using image analysis. As a result, hematocrits on the ridge region with gaps of 45 μm, 31 μm, and 25 μm were calculated as 1.0%, 0.6%, and 0.3%, respectively. Maximum skimming efficiency in this study was calculated as 70% with a gap of 25 μm. We confirmed that separation of erythrocyte and plasma occurred in the spiral groove bearing with decrease in bearing gap in a hydrodynamically levitated centrifugal blood pump.

  16. Mean circulatory filling pressure: its meaning and measurement.

    PubMed

    Rothe, C F

    1993-02-01

    The volume-pressure relationship of the vasculature of the body as a whole, its vascular capacitance, requires a measurement of the mean circulatory filling pressure (Pmcf). A change in vascular capacitance induced by reflexes, hormones, or drugs has physiological consequences similar to a rapid change in blood volume and thus strongly influences cardiac output. The Pmcf is defined as the mean vascular pressure that exists after a stop in cardiac output and redistribution of blood, so that all pressures are the same throughout the system. The Pmcf is thus related to the fullness of the circulatory system. A change in Pmcf provides a uniquely useful index of a change in overall venous smooth muscle tone if the blood volume is not concomitantly changed. The Pmcf also provides an estimate of the distending pressure in the small veins and venules, which contain most of the blood in the body and comprise most of the vascular compliance. Thus the Pmcf, which is normally independent of the magnitude of the cardiac output, provides an estimate of the upstream pressure that determines the rate of flow returning to the heart.

  17. [Application of artificial neural networks in forecasting the number of circulatory system diseases death toll].

    PubMed

    Zhang, Ying; Shao, Yi; Shang, Kezheng; Wang, Shigong; Wang, Jinyan

    2014-09-01

    Set up the model of forecasting the number of circulatorys death toll based on back-propagation (BP) artificial neural networks discuss the relationship between the circulatory system diseases death toll meteorological factors and ambient air pollution. The data of tem deaths, meteorological factors, and ambient air pollution within the m 2004 to 2009 in Nanjing were collected. On the basis of analyzing the ficient between CSDDT meteorological factors and ambient air pollution, leutral network model of CSDDT was built for 2004 - 2008 based on factors and ambient air pollution within the same time, and the data of 2009 est the predictive power of the model. There was a closely system diseases relationship between meteorological factors, ambient air pollution and the circulatory system diseases death toll. The ANN model structure was 17 -16 -1, 17 input notes, 16 hidden notes and 1 output note. The training precision was 0. 005 and the final error was 0. 004 999 42 after 487 training steps. The results of forecast show that predict accuracy over 78. 62%. This method is easy to be finished with smaller error, and higher ability on circulatory system death toll on independent prediction, which can provide a new method for forecasting medical-meteorological forecast and have the value of further research.

  18. Extracorporeal gas exchange with the DeltaStream rotary blood pump in experimental lung injury.

    PubMed

    Dembinski, Rolf; Kopp, Rüdger; Henzler, Dietrich; Hochhausen, Nadine; Oslender, Nicole; Max, Martin; Rossaint, Rolf; Kuhlen, Ralf

    2003-06-01

    In most severe cases of the acute respiratory distress syndrome, veno-venous extracorporeal membrane oxygenation (ECMO) can be used to facilitate gas exchange. However, the clinical use is limited due to the size and the concomitant risk of severe adverse events of conventionally-used centrifugal blood pumps with high extracorporeal blood volumes. The DeltaStream blood pump is a small-sized rotary blood pump that may reduce extracorporeal blood volume, foreign surfaces, contact activation of the coagulation system, and blood trauma. The aim of the present study was to test the safety and efficacy of the DeltaStream pump for ECMO in animals with normal lung function and experimental acute lung injury (ALI). Therefore, veno-venous ECMO was performed for 6 hours in mechanically ventilated pigs with normal lung function (n=6) and with ALI induced by repeated lung lavage (n=6) with a blood flow of 30% of the cardiac output. Gas flow with a FiO2 of 1.0 was set to equal blood flow. With a mean activated clotting time of 121 +/- 22 s, no circulatory impairment or thrombus formation was revealed during ECMO. Furthermore, free plasma Hb did not increase. In controls, hemodynamics and gas exchange remained unchanged. In animals with ALI, hemodynamics remained stable and gas transfer across the extracorporeal oxygenators was optimal, but only in 2 animals was a marked increase in PaO2 observed. CO2 removal was efficacious in all animals. We concluded that the DeltaStream blood pump may be used for veno-venous ECMO without major blood damage or hemodynamic impairment.

  19. Addressing Consent Issues in Donation After Circulatory Determination of Death.

    PubMed

    Overby, Kim J; Weinstein, Michael S; Fiester, Autumn

    2015-01-01

    Given the widening gap between the number of individuals on transplant waiting lists and the availability of donated organs, as well as the recent plateau in donations based on neurological criteria (i.e., brain death), there has been a growing interest in expanding donation after circulatory determination of death. While the prevalence of this form of organ donation continues to increase, many thorny ethical issues remain, often creating moral distress in both clinicians and families. In this article, we address one of these issues, namely, the challenges surrounding patient and surrogate informed consent for donation after circulatory determination of death. First we discuss several general concerns regarding consent related to this form of organ donation, and then we address additional issues that are unique to three different patient categories: adult patients with medical decision-making capacity or potential capacity, adult patients who lack capacity, and pediatric patients.

  20. Impact of Selected Socio-demographic Factors on the Development of Mortality due to Circulatory System Diseases in the Slovak Republic.

    PubMed

    Gavurová, Beáta; Kubák, Matúš

    2017-12-01

    We mapped the situation within a group of diseases of the circulatory system (I00-I99) in the Slovak Republic during 1996-2014. We focused mainly on spatiotemporal differences in mortality while controlling for age and sex. We performed binary logistic regression aiming to reveal socio-demographic factors that influence the odds of dying due to diseases of the circulatory system (I00-I99). In our analysis, the dependent variable was death diagnosis and the independent variables were age, region, gender, and marital status. Our findings suggest that odds of dying due to diseases of the circulatory system (I00-I99) increased for every year of age by 5.4%. Within the period from 1996 to 2014, the risk of dying from diseases of the circulatory system decreased by 2% every year. We also documented the fact that being female raised the odds of dying due to diseases of the circulatory system (I00-I99) by 12.9% compared to males. Furthermore, it could be argued that serious differences in terms of regional distribution of deaths caused by diseases of the circulatory system (I00-I99) exist in the Slovak Republic. We present the development of diseases of the circulatory system (I00-I99) in the Slovak Republic. Differences in spatial distribution of deaths are documented as well as related gender differences. Our study can serve as a tool for policy makers and benchmark for professionals. Copyright© by the National Institute of Public Health, Prague 2017.

  1. Clinical trial design and rationale of the Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3 (MOMENTUM 3) investigational device exemption clinical study protocol.

    PubMed

    Heatley, Gerald; Sood, Poornima; Goldstein, Daniel; Uriel, Nir; Cleveland, Joseph; Middlebrook, Don; Mehra, Mandeep R

    2016-04-01

    The HeartMate 3 left ventricular assist system (LVAS; St. Jude Medical, Inc., formerly Thoratec Corporation, Pleasanton, CA) was recently introduced into clinical trials for durable circulatory support in patients with medically refractory advanced-stage heart failure. This centrifugal, fully magnetically levitated, continuous-flow pump is engineered with the intent to enhance hemocompatibility and reduce shear stress on blood elements, while also possessing intrinsic pulsatility. Although bridge-to-transplant (BTT) and destination therapy (DT) are established dichotomous indications for durable left ventricular assist device (LVAD) support, clinical practice has challenged the appropriateness of these designations. The introduction of novel LVAD technology allows for the development of clinical trial designs to keep pace with current practices. The prospective, randomized Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3 (MOMENTUM 3) clinical trial aims to evaluate the safety and effectiveness of the HeartMate 3 LVAS by demonstrating non-inferiority to the HeartMate II LVAS (also St. Jude Medical, Inc.). The innovative trial design includes patients enrolled under a single inclusion and exclusion criteria , regardless of the intended use of the device, with outcomes ascertained in the short term (ST, at 6 months) and long term (LT, at 2 years). This adaptive trial design includes a pre-specified safety phase (n = 30) analysis. The ST cohort includes the first 294 patients and the LT cohort includes the first 366 patients for evaluation of the composite primary end-point of survival to transplant, recovery or LVAD support free of debilitating stroke (modified Rankin score >3), or re-operation to replace the pump. As part of the adaptive design, an analysis by an independent statistician will determine whether sample size adjustment is required at pre-specified times during the study. A further 662

  2. High-risk medical devices, children and the FDA: regulatory challenges facing pediatric mechanical circulatory support devices.

    PubMed

    Almond, Christopher S D; Chen, Eric A; Berman, Michael R; Less, Joanne R; Baldwin, J Timothy; Linde-Feucht, Sarah R; Hoke, Tracey R; Pearson, Gail D; Jenkins, Kathy; Duncan, Brian W; Zuckerman, Bram D

    2007-01-01

    Pediatric mechanical circulatory support is a critical unmet need in the United States. Infant- and child-sized ventricular assist devices are currently being developed largely through federal contracts and grants through the National Heart, Lung, and Blood Institute (NHLBI). Human testing and marketing of high-risk devices for children raises epidemiologic and regulatory issues that will need to be addressed. Leaders from the US Food and Drug Administration (FDA), NHLBI, academic pediatric community, and industry convened in January 2006 for the first FDA Workshop on the Regulatory Process for Pediatric Mechanical Circulatory Support Devices. The purpose was to provide the pediatric community with an overview of the federal regulatory process for high-risk medical devices and to review the challenges specific to the development and regulation of pediatric mechanical circulatory support devices. Pediatric mechanical circulatory support present significant epidemiologic, logistic, and financial challenges to industry, federal regulators, and the pediatric community. Early interactions with the FDA, shared appreciation of challenges, and careful planning will be critical to avoid unnecessary delays in making potentially life-saving devices available for children. Collaborative efforts to address these challenges are warranted.

  3. In vitro comparison of support capabilities of intra-aortic balloon pump and Impella 2.5 left percutaneous.

    PubMed

    Schampaert, Stéphanie; van't Veer, Marcel; van de Vosse, Frans N; Pijls, Nico H J; de Mol, Bas A; Rutten, Marcel C M

    2011-09-01

    The Impella 2.5 left percutaneous (LP), a relatively new transvalvular assist device, challenges the position of the intra-aortic balloon pump (IABP), which has a long record in supporting patients after myocardial infarction and cardiac surgery. However, while more costly and more demanding in management, the advantages of the Impella 2.5 LP are yet to be established. The aim of this study was to evaluate the benefits of the 40 cc IABP and the Impella 2.5 LP operating at 47,000 rpm in vitro, and compare their circulatory support capabilities in terms of cardiac output, coronary flow, cardiac stroke work, and arterial blood pressure. Clinical scenarios of cardiogenic preshock and cardiogenic shock (CS), with blood pressure depression, lowered cardiac output, and constant heart rate of 80 bpm, were modeled in a model-controlled mock circulation, featuring a systemic, pulmonary, and coronary vascular bed. The ventricles, represented by servomotor-operated piston pumps, included the Frank-Starling mechanism. The systemic circulation was modeled with a flexible tube having close-to-human aortic dimensions and compliance properties. Proximally, it featured a branch mimicking the brachiocephalic arteries and a physiological correct coronary flow model. The rest of the systemic and pulmonary impedance was modeled by four-element Windkessel models. In this system, the enhancement of coronary flow and blood pressure was tested with both support systems under healthy and pathological conditions. Hemodynamic differences between the IABP and the Impella 2.5 LP were small. In our laboratory model, both systems approximately yielded a 10% cardiac output increase and a 10% coronary flow increase. However, since the Impella 2.5 LP provided significantly better left ventricular unloading, the circulatory support capabilities were slightly in favor of the Impella 2.5 LP. On the other hand, pulsatility was enhanced with the IABP and lowered with the Impella 2.5 LP. The support

  4. Cavopulmonary support with a microaxial pump for the failing Fontan physiology.

    PubMed

    Zhu, Jiaquan; Kato, Hideyuki; Fu, Yaqin Y; Zhao, Lisa; Foreman, Celeste; Davey, Lisa; Weisel, Richard D; Van Arsdell, Glen S; Honjo, Osami

    2015-01-01

    The number of patients with the failing Fontan physiology is increasing. We tested a novel in situ microaxial pump (Impella) to support the failing atrio-pulmonary Fontan circulation in an acute pig model. A Fontan model was established in eight juvenile pigs by connecting the right atrium to the main pulmonary artery after tricuspid valve destruction. The Impella pump was inserted retrograde from the distal main pulmonary artery into the right atrium. Hemodynamics, blood gas, and echocardiographic data were compared among baseline, pure Fontan physiology (10 minutes), and mechanically assisted Fontan physiology (up to 12 hours). The Impella system generated a blood flow of 75-85 ml/kg/minute in six animals, and 55-65 ml/kg/minute in two animals. The mechanically assisted Fontan attained a significantly higher mean blood pressure (39.6 ± 7 vs. 24.7 ± 3.3 mm Hg, p < 0.01), lower central venous pressure (5 ± 2.4 vs. 12.8 ± 1.7 mm Hg, p < 0.01), and higher mixed venous saturation (60.4 ± 10.8 vs. 23.4 ± 8.4 mm Hg, p < 0.01) compared with pure Fontan physiology. Cardiac output and stroke volume were similar during baseline and mechanically assisted Fontan (p = not significant). This acute pig study demonstrated the feasibility of mechanical circulatory support in the failing Fontan physiology. The in situ microaxial pump maintained cardiac output while increasing blood pressure and reducing venous pressure.

  5. Management of intra-abdominal hypertension and abdominal compartment syndrome: a review

    PubMed Central

    2014-01-01

    Patients in the intensive care unit (ICU) are at risk of developing of intra abdominal hypertension (IAH) and abdominal compartment syndrome (ACS). Aim: This review seeks to define IAH and ACS, identify the aetiology and presentation of IAH and ACS, identify IAP measurement techniques, identify current management and discuss the implications of IAH and ACS for nursing practice. A search of the electronic databases was supervised by a health librarian. The electronic data bases Cumulative Index of Nursing and Allied Health Literature (CINAHL); Medline, EMBASE, and the World Wide Web was undertaken from 1996- January 2011 using MeSH and key words which included but not limited to: abdominal compartment syndrome, intra -abdominal hypertension, intra-abdominal pressure in adult populations met the search criteria and were reviewed by three authors using a critical appraisal tool. Data derived from the retrieved material are discussed under the following themes: (1) etiology of intra-abdominal hypertension; (2) strategies for measuring intra-abdominal pressure (3) the manifestation of abdominal compartment syndrome; and (4) the importance of nursing assessment, observation and interventions. Intra-abdominal pressure (IAP) and abdominal compartment syndrome (ACS) have the potential to alter organ perfusion and compromise organ function. PMID:24499574

  6. CHF: circulatory homeostasis gone awry.

    PubMed

    Weber, Karl T; Burlew, Brad S; Davis, Richard C; Newman, Kevin P; D'Cruz, Ivan A; Hawkins, Ralph G; Wall, Barry M; Parker, Robert B

    2002-01-01

    The role of the renin-angiotensin-aldosterone system (RAAS) is integral to salt and water retention, particularly by the kidneys. Over time, positive sodium balance leads first to intra- and then to extravascular volume expansion, with subsequent symptomatic heart failure. This report examines the role of the RAAS in regulating a less well recognized component essential to circulatory homeostasis--central blood volume. The regulation of central blood volume draws on integrative cardiorenal physiology and a key role played by the RAAS in its regulation. In presenting insights into the role of the RAAS in regulating central blood volume, this review also addresses other sodium-retaining states with a predisposition to edema formation, such as cirrhosis and nephrosis. (c)2002 CHF, Inc

  7. A Comparative Study of Different Hypothermic Circulatory Arrest Strategies on Aortic Surgery.

    ClinicalTrials.gov

    2018-03-22

    Morality; Hypothermic Circulatory Arrest Time; Aortic-cross Clamping Time; Cardiopulmonary Bypass Time; Operation Time; Re-Thoracotomy; ICU Stay; Mechanical Ventilation Time; Blood Transfusion; Neurological Disorder; Dialysis; Aneurysm; Endoleak; Hospital Stay

  8. Deep hypothermic circulatory arrest

    PubMed Central

    Ziganshin, Bulat A.

    2013-01-01

    Effective cerebral protection remains the principle concern during aortic arch surgery. Hypothermic circulatory arrest (HCA) is entrenched as the primary neuroprotection mechanism since the 70s, as it slows injury-inducing pathways by limiting cerebral metabolism. However, increases in HCA duration has been associated with poorer neurological outcomes, necessitating the adjunctive use of antegrade (ACP) and retrograde cerebral perfusion (RCP). ACP has superseded RCP as the preferred perfusion strategy as it most closely mimic physiological perfusion, although there exists uncertainty regarding several technical details, such as unilateral versus bilateral perfusion, flow rate and temperature, perfusion site, undue trauma to head vessels, and risks of embolization. Nevertheless, we believe that the convenience, simplicity and effectiveness of straight DHCA justifies its use in the majority of elective and emergency cases. The following perspective offers a historical and clinical comparison of the DHCA with other techniques of cerebral protection. PMID:23977599

  9. Practical Considerations in Donation After Circulatory Determination of Death in Switzerland.

    PubMed

    Dalle Ave, Anne L; Shaw, David M; Elger, Bernice

    2017-09-01

    Faced with similar issues of organ scarcity to its neighbors, Switzerland has developed donation after circulatory determination of death (DCDD) as a way to expand the organ pool since 1985. Here, we analyze the history, practical considerations, and ethical issues relating to the Swiss donation after circulatory death programs. In Switzerland, determination of death for DCDD requires a stand-off period of 10 minutes. This time between cardiac arrest and the declaration of death is mandated in the guidelines of the Swiss Academy of Medical Sciences. As in other DCDD programs, safeguards are put to avoid physicians denying lifesaving treatment to savable patients because of being influenced by receivers' interest. An additional recommendation could be made: Recipients should be transparently informed of the worse graft outcomes with DCDD programs and given the possibility to refuse such organs.

  10. Radiation-associated circulatory disease mortality in a pooled analysis of 77,275 patients from the Massachusetts and Canadian tuberculosis fluoroscopy cohorts.

    PubMed

    Tran, Van; Zablotska, Lydia B; Brenner, Alina V; Little, Mark P

    2017-03-13

    High-dose ionising radiation is associated with circulatory disease. Risks associated with lower-dose (<0.5 Gy) exposures remain unclear, with little information on risk modification by age at exposure, years since exposure or dose-rate. Tuberculosis patients in Canada and Massachusetts received multiple diagnostic x-ray fluoroscopic exposures, over a wide range of ages, many at doses <0.5 Gy. We evaluated risks of circulatory-disease mortality associated with <0.5 Gy radiation exposure in a pooled cohort of 63,707 patients in Canada and 13,568 patients in Massachusetts. Under 0.5 Gy there are increasing trends for all circulatory disease (n = 10,209; excess relative risk/Gy = 0.246; 95% CI 0.036, 0.469; p = 0.021) and for ischaemic heart disease (n = 6410; excess relative risk/Gy = 0.267; 95% CI 0.003, 0.552; p = 0.048). All circulatory-disease and ischaemic-heart-disease risk reduces with increasing time since exposure (p < 0.005). Over the entire dose range, there are negative mortality dose trends for all circulatory disease (p = 0.014) and ischaemic heart disease (p = 0.003), possibly due to competing causes of death over this dose interval.These results confirm and extend earlier findings and strengthen the evidence for circulatory-disease mortality radiation risk at doses <0.5 Gy. The limited information on well-known lifestyle/medical risk factors for circulatory disease implies that confounding of the dose trend cannot be entirely excluded.

  11. Computational Quantification of the Cardiac Energy Consumption during Intra-Aortic Balloon Pumping Using a Cardiac Electromechanics Model

    PubMed Central

    Lim, Ki Moo; Lee, Jeong Sang; Gyeong, Min-Soo; Choi, Jae-Sung; Choi, Seong Wook

    2013-01-01

    To quantify the reduction in workload during intra-aortic balloon pump (IABP) therapy, indirect parameters are used, such as the mean arterial pressure during diastole, product of heart rate and peak systolic pressure, and pressure-volume area. Therefore, we investigated the cardiac energy consumption during IABP therapy using a cardiac electromechanics model. We incorporated an IABP function into a previously developed electromechanical model of the ventricle with a lumped model of the circulatory system and investigated the cardiac energy consumption at different IABP inflation volumes. When the IABP was used at inflation level 5, the cardiac output and stroke volume increased 11%, the ejection fraction increased 21%, the stroke work decreased 1%, the mean arterial pressure increased 10%, and the ATP consumption decreased 12%. These results show that although the ATP consumption is decreased significantly, stroke work is decreased only slightly, which indicates that the IABP helps the failed ventricle to pump blood efficiently. PMID:23341718

  12. Computational quantification of the cardiac energy consumption during intra-aortic balloon pumping using a cardiac electromechanics model.

    PubMed

    Lim, Ki Moo; Lee, Jeong Sang; Gyeong, Min-Soo; Choi, Jae-Sung; Choi, Seong Wook; Shim, Eun Bo

    2013-01-01

    To quantify the reduction in workload during intra-aortic balloon pump (IABP) therapy, indirect parameters are used, such as the mean arterial pressure during diastole, product of heart rate and peak systolic pressure, and pressure-volume area. Therefore, we investigated the cardiac energy consumption during IABP therapy using a cardiac electromechanics model. We incorporated an IABP function into a previously developed electromechanical model of the ventricle with a lumped model of the circulatory system and investigated the cardiac energy consumption at different IABP inflation volumes. When the IABP was used at inflation level 5, the cardiac output and stroke volume increased 11%, the ejection fraction increased 21%, the stroke work decreased 1%, the mean arterial pressure increased 10%, and the ATP consumption decreased 12%. These results show that although the ATP consumption is decreased significantly, stroke work is decreased only slightly, which indicates that the IABP helps the failed ventricle to pump blood efficiently.

  13. A compact highly efficient and low hemolytic centrifugal blood pump with a magnetically levitated impeller.

    PubMed

    Asama, Junichi; Shinshi, Tadahiko; Hoshi, Hideo; Takatani, Setsuo; Shimokohbe, Akira

    2006-03-01

    A magnetically levitated (maglev) centrifugal blood pump (CBP), intended for use as a ventricular assist device, needs to be highly durable and reliable for long-term use without any mechanical failure. Furthermore, maglev CBPs should be small enough to be implanted into patients of various size and weight. We have developed a compact maglev CBP employing a two-degree-of-freedom controlled magnetic bearing, with a magnetically suspended impeller directly driven by an internal brushless direct current (DC) motor. The magnetic bearing actively controls the radial motion of the impeller and passively supports axial and angular motions using a permanent magnet embedded in the impeller. The overall dimensions of the maglev CBP are 65 mm in diameter and 40 mm in height. The total power consumption and pump efficiency for pumping 6 L/min against a head pressure of 105 mm Hg were 6.5 W and 21%, respectively. To evaluate the characteristics of the maglev CBP when subjected to a disturbance, excitation of the base, simulating the movement of the patient in various directions, and the sudden interception of the outlet tube connected with the pump in a mock circulatory loop, simulating an unexpected kink and emergent clamp during a heart surgery, were tested by monitoring the five-degree-of-freedom motion of the impeller. Furthermore, the hemolytic characteristics of the maglev CBP were compared with those of the Medtronic Biomedicus BPX-80, which demonstrated the superiority of the maglev CBP.

  14. Abdominal epilepsy as an unusual cause of abdominal pain: a case report.

    PubMed

    Yunus, Yilmaz; Sefer, Ustebay; Dondu, Ulker Ustebay; Ismail, Ozanli; Yusuf, Ehi

    2016-09-01

    Abdominal pain, in etiology sometimes difficult to be defined, is a frequent complaint in childhood. Abdominal epilepsy is a rare cause of abdominal pain. In this article, we report on 5 year old girl patient with abdominal epilepsy. Some investigations (stool investigation, routine blood tests, ultrasonography (USG), electrocardiogram (ECHO) and electrocardiograpy (ECG), holter for 24hr.) were done to understand the origin of these complaints; but no abnormalities were found. Finally an EEG was done during an episode of abdominal pain and it was shown that there were generalized spikes especially precipitated by hyperventilation. The patient did well on valproic acid therapy and EEG was normal 1 month after beginning of the treatment. The cause of chronic recurrent paroxymal abdominal pain is difficult for the clinicians to diagnose in childhood. A lot of disease may lead to paroxysmal gastrointestinal symptoms like familial mediterranean fever and porfiria. Abdominal epilepsy is one of the rare but easily treatable cause of abdominal pain. In conclusion, abdominal epilepsy should be suspected in children with recurrent abdominal pain.

  15. The Circulatory System [and] Instructor's Guide: The Circulatory System. Health Occupations Education Module: Instructional Materials in Anatomy and Physiology for Pennsylvania Health Occupations Programs.

    ERIC Educational Resources Information Center

    National Evaluation Systems, Inc., Amherst, MA.

    This module on the circulatory system is one of 17 modules designed for individualized instruction in health occupations education programs at both the secondary and postsecondary levels. It is part of an eight-unit subset on anatomy and physiology within the set of 17 modules. Following a preface which explains to the student how to use the…

  16. Contribution of Circulatory Disturbances in Subchondral Bone to the Pathophysiology of Osteoarthritis.

    PubMed

    Aaron, Roy K; Racine, Jennifer; Dyke, Jonathan P

    2017-08-01

    This review describes the contributions of abnormal bone circulation to the pathophysiology of osteoarthritis. Combining dynamic imaging with MRI and PET with previous observations reveals that venous stasis and a venous outlet syndrome is most likely the key circulatory pathology associated with the initiation or progression of osteoarthritis. MRI and PET have revealed that venous outflow obstruction results in physicochemical changes in subchondral bone to which osteoblasts are responsive. The osteoblasts express an altered pattern of cytokines, many of which can serve as structural or signaling molecules contributing to both bone remodeling and cartilage degeneration. The patterns of circulatory changes are associated with alterations in the physicochemical environment of subchondral bone, including hypoxia. Osteoblast cytokines can transit the subchondral bone plate and calcified cartilage and communicate with chondrocytes.

  17. Using the brain criterion in organ donation after the circulatory determination of death.

    PubMed

    Dalle Ave, Anne L; Bernat, James L

    2016-06-01

    The UK, France, and Switzerland determine death using the brain criterion even in organ donation after the circulatory determination of death (DCDD), in which the United States and Canada use the circulatory-respiratory criterion. In our analysis of the scientific validity of the brain criterion in DCDD, we concluded that although it may be attractive in theory because it conceptualizes death as a unitary phenomenon, its use in practice is invalid. The preconditions (ie, the absence of reversible causes, such as toxic or metabolic disorders) for determining brain death cannot be met in DCDD. Thus, although brain death tests prove the cessation of tested brain functions, they do not prove that their cessation is irreversible. A stand-off period of 5 to 10 minutes is insufficient to achieve the irreversibility requirement of brain death. Because circulatory cessation inevitably leads to cessation of brain functions, first permanently and then irreversibly, the use of brain criterion is unnecessary to determine death in DCDD. Expanding brain death to permit it to be satisfied by permanent cessation of brain functions is controversial but has been considered as a possible means to declare death in uncontrolled DCDD. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Calcification detection of abdominal aorta in CT images and 3D visualization in VR devices.

    PubMed

    Garcia-Berna, Jose A; Sanchez-Gomez, Juan M; Hermanns, Judith; Garcia-Mateos, Gines; Fernandez-Aleman, Jose L

    2016-08-01

    Automatic calcification detection in abdominal aorta consists of a set of computer vision techniques to quantify the amount of calcium that is found around this artery. Knowing that information, it is possible to perform statistical studies that relate vascular diseases with the presence of calcium in these structures. To facilitate the detection in CT images, a contrast is usually injected into the circulatory system of the patients to distinguish the aorta from other body tissues and organs. This contrast increases the absorption of X-rays by human blood, making it easier the measurement of calcifications. Based on this idea, a new system capable of detecting and tracking the aorta artery has been developed with an estimation of the calcium found surrounding the aorta. Besides, the system is complemented with a 3D visualization mode of the image set which is designed for the new generation of immersive VR devices.

  19. Noninvasive optoacoustic system for rapid diagnosis and management of circulatory shock

    NASA Astrophysics Data System (ADS)

    Petrov, Irene Y.; Kinsky, Michael; Petrov, Yuriy; Petrov, Andrey; Henkel, S. N.; Seeton, Roger; Esenaliev, Rinat O.; Prough, Donald S.

    2013-03-01

    Circulatory shock can lead to death or severe complications, if not promptly diagnosed and effectively treated. Typically, diagnosis and management of circulatory shock are guided by blood pressure and heart rate. However, these variables have poor specificity, sensitivity, and predictive value. Early goal-directed therapy in septic shock patients, using central venous catheterization (CVC), reduced mortality from 46.5% to 30%. However, CVC is invasive and complication-prone. We proposed to use an optoacoustic technique for noninvasive, rapid assessment of peripheral and central venous oxygenation. In this work we used a medical grade optoacoustic system for noninvasive, ultrasound image-guided measurement of central and peripheral venous oxygenation. Venous oxygenation during shock declines more rapidly in the periphery than centrally. Ultrasound imaging of the axillary [peripheral] and internal jugular vein [central] was performed using the Vivid e (GE Healthcare). We built an optoacoustic interface incorporating an optoacoustic transducer and a standard ultrasound imaging probe. Central and peripheral venous oxygenations were measured continuously in healthy volunteers. To simulate shock-induced changes in central and peripheral oxygenation, we induced peripheral vasoconstriction in the upper extremity by using a cooling blanket. Central and peripheral venous oxygenations were measured before (baseline) and after cooling and after rewarming. During the entire experiment, central venous oxygenation was relatively stable, while peripheral venous oxygenation decreased by 5-10% due to cooling and recovered after rewarming. The obtained data indicate that noninvasive, optoacoustic measurements of central and peripheral venous oxygenation may be used for diagnosis and management of circulatory shock with high sensitivity and specificity.

  20. Intra-Abdominal Hypertension and Abdominal Compartment Syndrome in Association with Ruptured Abdominal Aortic Aneurysm in the Endovascular Era: Vigilance Remains Critical

    PubMed Central

    Bozeman, Matthew C.; Ross, Charles B.

    2012-01-01

    Intra-abdominal hypertension (IAH) and abdominal compartment syndrome (ACS) are common complications of ruptured abdominal aortoiliac aneurysms (rAAAs) and other abdominal vascular catastrophes even in the age of endovascular therapy. Morbidity and mortality due to systemic inflammatory response syndrome (SIRS) and multiple organ failure (MOF) are significant. Recognition and management of IAH are key critical care measures which may decrease morbidity and improve survival in these vascular patients. Two strategies have been utilized: expectant management with prompt decompressive laparotomy upon diagnosis of threshold levels of IAH versus prophylactic, delayed abdominal closure based upon clinical parameters at the time of initial repair. Competent management of the abdominal wound with preservation of abdominal domain is also an important component of the care of these patients. In this review, we describe published experience with IAH and ACS complicating abdominal vascular catastrophes, experience with ACS complicating endovascular repair of rAAAs, and techniques for management of the abdominal wound. Vigilance and appropriate management of IAH and ACS remains critically important in decreasing morbidity and optimizing survival following catastrophic intra-abdominal vascular events. PMID:22454763

  1. Intra-abdominal hypertension and abdominal compartment syndrome in association with ruptured abdominal aortic aneurysm in the endovascular era: vigilance remains critical.

    PubMed

    Bozeman, Matthew C; Ross, Charles B

    2012-01-01

    Intra-abdominal hypertension (IAH) and abdominal compartment syndrome (ACS) are common complications of ruptured abdominal aortoiliac aneurysms (rAAAs) and other abdominal vascular catastrophes even in the age of endovascular therapy. Morbidity and mortality due to systemic inflammatory response syndrome (SIRS) and multiple organ failure (MOF) are significant. Recognition and management of IAH are key critical care measures which may decrease morbidity and improve survival in these vascular patients. Two strategies have been utilized: expectant management with prompt decompressive laparotomy upon diagnosis of threshold levels of IAH versus prophylactic, delayed abdominal closure based upon clinical parameters at the time of initial repair. Competent management of the abdominal wound with preservation of abdominal domain is also an important component of the care of these patients. In this review, we describe published experience with IAH and ACS complicating abdominal vascular catastrophes, experience with ACS complicating endovascular repair of rAAAs, and techniques for management of the abdominal wound. Vigilance and appropriate management of IAH and ACS remains critically important in decreasing morbidity and optimizing survival following catastrophic intra-abdominal vascular events.

  2. Abdominal Assessment.

    PubMed

    Fritz, Deborah; Weilitz, Pamela Becker

    2016-03-01

    Abdominal pain is one of the most common complaints by patients, and assessment of abdominal pain and associated symptoms can be challenging for home healthcare providers. Reasons for abdominal pain are related to inflammation, organ distention, and ischemia. The history and physical examination are important to narrow the source of acute or chronic problems, identify immediate interventions, and when necessary, facilitate emergency department care.

  3. Circulatory oxygen transport in the water flea Daphnia magna.

    PubMed

    Bäumer, C; Pirow, R; Paul, R J

    2002-05-01

    To determine the contribution of circulatory convection to tissue oxygen supply in animals of Daphnia magna, heart rate ( f(H)), in-vivo Hb oxygen-saturation ( S(Hb)) and NADH fluorescence intensity ( I(NADH)) as a measure of the tissue oxygenation state were simultaneously measured using digital motion analysis, microabsorption spectroscopy and fluorescence microscopy. In addition, the relationship between stroke volume and body size was established. Groups of differently sized animals (small: 1.4-1.6 mm, medium: 2.7-2.9 mm, large: 3.3 mm) with either low (Hb-poor) or high Hb concentration (Hb-rich) in the hemolymph were exposed to a gradual decrease in ambient oxygen partial pressure ( P(O2amb)) between normoxia and anoxia. In all groups, f(H) increased in response to progressive hypoxia. The hypoxic maximum in f(H) was highest in medium-sized Hb-poor animals, whereas perfusion rate increased continuously with increasing body size in Hb-poor and Hb-rich animals. The P(O2amb) at which Hb in the heart region was half-saturated (in-vivo P(50)) was higher in medium-sized (Hb-poor: 3.2 kPa, Hb-rich: 2.0 kPa) than in small (Hb-poor: 2.1 kPa, Hb-rich: 1.5 kPa) and large animals (Hb-poor: 1.9 kPa). The in-vivo P(50) was always lower in Hb-rich than in Hb-poor animals. The I(NADH) indicated an impairment of tissue oxygenation starting at higher critical P(O2amb) with increasing body size and with lower Hb concentration. Model calculations suggest that at the respective critical P(O2amb), circulatory convection delivers less than half of the oxygen demand in Hb-poor animals. In contrast, in Hb-rich animals, the contribution of circulatory convection to tissue oxygen supply at respective critical P(O2amb) was much greater due to the higher concentration of Hb.

  4. Mean circulatory filling pressure: potential problems with measurement.

    PubMed

    Gaddis, M L; Rothe, C F; Tunin, R S; Moran, M; MacAnespie, C L

    1986-10-01

    Three experimental series using 22 acutely splenectomized mongrel dogs were completed to 1) compare fibrillation (Fib) and acetylcholine (ACh) injection as methods to stop the heart for the mean circulatory filling pressure (Pmcf) maneuver, and 2) test whether Pmcf equals portal venous pressure 7 s after heart stoppage (Pportal7s). Blood volume changes of -10, -20, +10, or +20 ml/kg were imposed and Pmcf and Pportal measurements were obtained. Pportal7s and Pmcf were significantly different with volume depletion but were similar under control conditions. Pmcf with ACh and Pmcf with Fib were significantly different only after a volume change of -20 ml/kg. However, severe pulmonary congestion and atelectasis were detected in animals where Ach was used to stop the heart. In some cases (with injection directly into the pulmonary artery) the damage was severe enough to cause irreversible arterial hypoxia. Thus we conclude that the repeated use of ACh may exert a detrimental influence on pulmonary function, changing the physiological status of the experimental animal. Also, the central venous pressure at 7 s of heart stoppage (Pcv7s) is not a fully accurate estimate of the true mean circulatory filling pressure during the Pmcf maneuver, because Pcv7s did not equal the Pportal7s under all experimental conditions.

  5. Abdominal Aortic Aneurysm

    MedlinePlus

    ... Kids and Teens Pregnancy and Childbirth Women Men Seniors Your Health Resources Healthcare Management End-of-Life ... familydoctor.org editorial staff Categories: Family Health, Men, Seniors, WomenTags: abdominal aorta, abdominal aortic aneurysm, abdominal pain, ...

  6. Intra-abdominal fluid extravasation during hip arthroscopy: a survey of the MAHORN group.

    PubMed

    Kocher, Mininder S; Frank, Jeremy S; Nasreddine, Adam Y; Safran, Marc R; Philippon, Marc J; Sekiya, Jon K; Kelly, Bryan T; Byrd, J W Thomas; Guanche, Carlos A; Martin, Hal D; Clohisy, John C; Mohtadi, Nick G; Griffin, Damian R; Sampson, Thomas G; Leunig, Michael; Larson, Christopher M; Ilizaliturri, Victor M; McCarthy, Joseph C; Gambacorta, Peter G

    2012-11-01

    The purpose of this study was to survey experts in the field of hip arthroscopy from the Multicenter Arthroscopy of the Hip Outcomes Research Network (MAHORN) group to determine the frequency of symptomatic intra-abdominal fluid extravasation (IAFE) after arthroscopic hip procedures, identify potential risk factors, and develop preventative measures and treatment strategies in the event of symptomatic IAFE. A survey was sent to all members of the MAHORN group. Surveys collected data on general hip arthroscopy settings, including pump pressure and frequency of different hip arthroscopies performed, as well as details on cases of symptomatic IAFE. Responses to the survey were documented and analyzed. Fifteen hip arthroscopists from the MAHORN group were surveyed. A total of 25,648 hip arthroscopies between 1984 and 2010 were reviewed. Arthroscopic procedures included capsulotomies, labral reattachment after acetabuloplasty, peripheral compartment arthroscopy, and osteoplasty of the femoral head-neck junction. Of the arthroscopists, 7 (47%) had 1 or more cases of IAFE (40 cases reported). The prevalence of IAFE in this study was 0.16% (40 of 25,650). Significant risk factors associated with IAFE were higher arthroscopic fluid pump pressure (P = .004) and concomitant iliopsoas tenotomy (P < .001). In all 40 cases, the condition was successfully treated without long-term sequelae. Treatment options included observation, intravenous furosemide, and Foley catheter placement, as well as 1 case of laparotomy. Symptomatic IAFE after hip arthroscopy is a rare occurrence, with an approximate prevalence of 0.16%. Prevention of IAFE should include close intraoperative and postoperative monitoring of abdominal distention, core body temperature, and hemodynamic stability. Concomitant iliopsoas tenotomy and high pump pressures may be risk factors leading to symptomatic IAFE. Level IV, therapeutic case series. Copyright © 2012 Arthroscopy Association of North America. Published by

  7. Physiological control of dual rotary pumps as a biventricular assist device using a master/slave approach.

    PubMed

    Stevens, Michael C; Wilson, Stephen; Bradley, Andrew; Fraser, John; Timms, Daniel

    2014-09-01

    Dual rotary left ventricular assist devices (LVADs) can provide biventricular mechanical support during heart failure. Coordination of left and right pump speeds is critical not only to avoid ventricular suction and to match cardiac output with demand, but also to ensure balanced systemic and pulmonary circulatory volumes. Physiological control systems for dual LVADs must meet these objectives across a variety of clinical scenarios by automatically adjusting left and right pump speeds to avoid catastrophic physiological consequences. In this study we evaluate a novel master/slave physiological control system for dual LVADs. The master controller is a Starling-like controller, which sets flow rate as a function of end-diastolic ventricular pressure (EDP). The slave controller then maintains a linear relationship between right and left EDPs. Both left/right and right/left master/slave combinations were evaluated by subjecting them to four clinical scenarios (rest, postural change, Valsalva maneuver, and exercise) simulated in a mock circulation loop. The controller's performance was compared to constant-rotational-speed control and two other dual LVAD control systems: dual constant inlet pressure and dual Frank-Starling control. The results showed that the master/slave physiological control system produced fewer suction events than constant-speed control (6 vs. 62 over a 7-min period). Left/right master/slave control had lower risk of pulmonary congestion than the other control systems, as indicated by lower maximum EDPs (15.1 vs. 25.2-28.4 mm Hg). During exercise, master/slave control increased total flow from 5.2 to 10.1 L/min, primarily due to an increase of left and right pump speed. Use of the left pump as the master resulted in fewer suction events and lower EDPs than when the right pump was master. Based on these results, master/slave control using the left pump as the master automatically adjusts pump speed to avoid suction and increases pump flow

  8. Intra-abdominal hypertension and abdominal compartment syndrome in pediatrics. A review.

    PubMed

    Thabet, Farah Chedly; Ejike, Janeth Chiaka

    2017-10-01

    To consolidate pediatric intensivists' understanding of the pathophysiology, definition, incidence, monitoring, and management of intra-abdominal hypertension (IAH) and abdominal compartment syndrome (ACS); and to highlight the characteristics related to the pediatric population. This is a narrative review article that utilized a systematic search of the medical literature published in the English language between January 1990 and august 2016. Studies were identified by conducting a comprehensive search of Pub Med databases. Search terms included "intra-abdominal hypertension and child", "intra-abdominal hypertension and pediatrics", "abdominal compartment syndrome and child", and "abdominal compartment syndrome and pediatrics". Intra-abdominal hypertension and ACS are associated with a number of pathophysiological disturbances and increased morbidity and mortality. These conditions have been well described in critically ill adults. In children, the IAH and the ACS have a reported incidence of 13% and 0.6 to 10% respectively; they carry similar prognostic impact but are still under-diagnosed and under-recognized by pediatric health care providers. Intra-abdominal hypertension and ACS are conditions that are regularly encountered in critically ill children. They are associated with an increased morbidity and mortality. Early recognition, prevention and timely management of this critical condition are necessary to improve its outcome. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Plain abdominal radiography in acute abdominal pain; past, present, and future

    PubMed Central

    Gans, Sarah L; Stoker, Jaap; Boermeester, Marja A

    2012-01-01

    Several studies have demonstrated that a diagnosis based solely on a patient’s medical history, physical examination, and laboratory tests is not reliable enough, despite the fact that these aspects are essential parts of the workup of a patient presenting with acute abdominal pain. Traditionally, imaging workup starts with abdominal radiography. However, numerous studies have demonstrated low sensitivity and accuracy for plain abdominal radiography in the evaluation of acute abdominal pain as well as various specific diseases such as perforated viscus, bowel obstruction, ingested foreign body, and ureteral stones. Computed tomography, and in particular computed tomography after negative ultrasonography, provides a better workup than plain abdominal radiography alone. The benefits of computed tomography lie in decision-making for management, planning of a surgical strategy, and possibly even avoidance of negative laparotomies. Based on abundant available evidence, major advances in diagnostic imaging, and changes in the management of certain diseases, we can conclude that there is no place for plain abdominal radiography in the workup of adult patients with acute abdominal pain presenting in the emergency department in current practice. PMID:22807640

  10. Abdominal Trauma Revisited.

    PubMed

    Feliciano, David V

    2017-11-01

    Although abdominal trauma has been described since antiquity, formal laparotomies for trauma were not performed until the 1800s. Even with the introduction of general anesthesia in the United States during the years 1842 to 1846, laparotomies for abdominal trauma were not performed during the Civil War. The first laparotomy for an abdominal gunshot wound in the United States was finally performed in New York City in 1884. An aggressive operative approach to all forms of abdominal trauma till the establishment of formal trauma centers (where data were analyzed) resulted in extraordinarily high rates of nontherapeutic laparotomies from the 1880s to the 1960s. More selective operative approaches to patients with abdominal stab wounds (1960s), blunt trauma (1970s), and gunshot wounds (1990s) were then developed. Current adjuncts to the diagnosis of abdominal trauma when serial physical examinations are unreliable include the following: 1) diagnostic peritoneal tap/lavage, 2) surgeon-performed ultrasound examination; 3) contrast-enhanced CT of the abdomen and pelvis; and 4) diagnostic laparoscopy. Operative techniques for injuries to the liver, spleen, duodenum, and pancreas have been refined considerably since World War II. These need to be emphasized repeatedly in an era when fewer patients undergo laparotomy for abdominal trauma. Finally, abdominal trauma damage control is a valuable operative approach in patients with physiologic exhaustion and multiple injuries.

  11. [Cerebral oximetry in pulmonary thromboendarterectomy with circulatory arrest].

    PubMed

    Catalán Escudero, P; González Román, A; Serra Ruiz, C N; Barbero Mielgo, M; García Fernández, J

    2014-02-01

    Pulmonary thromboendarterectomy is an uncommon procedure and should be performed with circulatory arrest. One of the major concerns is the postoperative central neurological injuries. Perioperative brain oxygen monitoring is advisable in this surgical procedure for the early detection of brain hypoperfusion episodes and their intensity as well as any other postoperative episodes that can deteriorate the neurological outcome. Copyright © 2012 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Published by Elsevier España. All rights reserved.

  12. Management of complex abdominal wall defects associated with penetrating abdominal trauma.

    PubMed

    Arul, G Suren; Sonka, B J; Lundy, J B; Rickard, R F; Jeffery, S L A

    2015-03-01

    The paradigm of Damage Control Surgery (DCS) has radically improved the management of abdominal trauma, but less well described are the options for managing the abdominal wall itself in an austere environment. This article describes a series of patients with complex abdominal wall problems managed at the UK-led Role 3 Medical Treatment Facility (MTF) in Camp Bastion, Afghanistan. Contemporaneous review of a series of patients with complex abdominal wall injuries who presented to the Role 3 MTF between July and November 2012. Five patients with penetrating abdominal trauma associated with significant damage to the abdominal wall were included. All patients were managed using DCS principles, leaving the abdominal wall open at the end of the first procedure. Subsequent management of the abdominal wall was determined by a multidisciplinary team of general and plastic surgeons, intensivists and specialist nurses. The principles of management identified included minimising tissue loss on initial laparotomy by joining adjacent wounds and marginal debridement of dead tissue; contraction of the abdominal wall was minimised by using topical negative pressure dressing and dermal-holding sutures. Definitive closure was timed to allow oedema to settle and sepsis to be controlled. Closure techniques include delayed primary closure with traction sutures, components separation, and mesh closure with skin grafting. A daily multidisciplinary team discussion was invaluable for optimal decision making regarding the most appropriate means of abdominal closure. Dermal-holding sutures were particularly useful in preventing myostatic contraction of the abdominal wall. A simple flow chart was developed to aid decision making in these patients. This flow chart may prove especially useful in a resource-limited environment in which returning months or years later for closure of a large ventral hernia may not be possible. Published by the BMJ Publishing Group Limited. For permission to use

  13. From Head to Toe: Respiratory, Circulatory, and Skeletal Systems. Book 3.

    ERIC Educational Resources Information Center

    Wiebe, Arthur, Ed.; And Others

    Designed to supplement curricular programs dealing with the human body, this booklet offers an activity-based, student-oriented approach for middle school teachers and students. Twelve activities focus on principles and skills related to the respiratory, circulatory, and skeletal systems. Each activity consists of student sheets and a teacher's…

  14. Application of drag-reducing polymer solutions as test fluids for in vitro evaluation of potential blood damage in blood pumps.

    PubMed

    Daly, Amanda R; Sobajima, Hideo; Olia, Salim E; Takatani, Setsuo; Kameneva, Marina V

    2010-01-01

    In vitro evaluation of the potential of a circulatory-assist device to damage blood cells has generally been performed using blood from various species. Problems with this approach include the variability of blood sensitivity to mechanical stress in different species, preparation of blood including the adjustment of hematocrit to a standard value, changes in the mechanical properties of blood that occur during storage, and necessity to pool blood samples to obtain an adequate amount of blood for in vitro circulating systems. We investigated whether the mechanical degradation of a drag-reducing polymer (DRP) solution resulting in the loss of drag-reducing ability can indicate the degree of shear-induced blood damage within blood pumps. DRP solution (polyethylene oxide, 4,500 kDa, 1,000 ppm) or porcine blood were driven through a turbulent flow system by a centrifugal pump, either the Bio-Pump BPX-80 (Medtronic, Inc.) or CentriMag (Levitronix LLC) at a constant pressure gradient of 300 mm Hg for 120 minutes. DRP mechanical degradation was evaluated by reduction of flow rate and solution viscosity. A proposed index of DRP mechanical degradation (PDI) is similar to the normalized index of hemolysis (NIH) typically used to quantify the results of in vitro testing of blood pumps. Results indicate that the mechanical degradation of DRP solutions may provide a sensitive standard method for the evaluation of potential blood trauma produced by blood pumps without the use of blood.

  15. Application of Drag-Reducing Polymer Solutions as Test Fluids for In Vitro Evaluation of Potential Blood Damage in Blood Pumps

    PubMed Central

    Daly, Amanda R.; Sobajima, Hideo; Olia, Salim E.; Takatani, Setsuo; Kameneva, Marina V.

    2011-01-01

    In vitro evaluation of the potential of a circulatory-assist device to damage blood cells has generally been performed using blood from various species. Problems with this approach include the variability of blood sensitivity to mechanical stress in different species, preparation of blood including the adjustment of hematocrit to a standard value, changes in the mechanical properties of blood that occur during storage, and necessity to pool blood samples to obtain an adequate amount of blood for in vitro circulating systems. We investigated whether the mechanical degradation of a drag-reducing polymer (DRP) solution resulting in the loss of drag-reducing ability can indicate the degree of shear-induced blood damage within blood pumps. DRP solution (polyethylene oxide, 4,500 kDa, 1,000 ppm) or porcine blood were driven through a turbulent flow system by a centrifugal pump, either the Bio-Pump BPX-80 (Medtronic, Inc.) or CentriMag (Levitronix LLC) at a constant pressure gradient of 300 mm Hg for 120 minutes. DRP mechanical degradation was evaluated by reduction of flow rate and solution viscosity. A proposed index of DRP mechanical degradation (PDI) is similar to the normalized index of hemolysis (NIH) typically used to quantify the results of in vitro testing of blood pumps. Results indicate that the mechanical degradation of DRP solutions may provide a sensitive standard method for the evaluation of potential blood trauma produced by blood pumps without the use of blood. PMID:20019596

  16. The value of plain abdominal radiographs in management of abdominal emergencies in Luth.

    PubMed

    Ashindoitiang, J A; Atoyebi, A O; Arogundade, R A

    2008-01-01

    The plain abdominal x-ray is still the first imaging modality in diagnosis of acute abdomen. The aim of this study was to find the value of plain abdominal x-ray in the management of abdominal emergencies seen in Lagos university teaching hospital. The accurate diagnosis of the cause of acute abdominal pain is one of the most challenging undertakings in emergency medicine. This is due to overlapping of clinical presentation and non-specific findings of physical and even laboratory data of the multifarious causes. Plain abdominal radiography is one investigation that can be obtained readily and within a short period of time to help the physician arrive at a correct diagnosis The relevance of plain abdominal radiography was therefore evaluated in the management of abdominal emergencies seen in Lagos over a 12 month period (April 2002 to March 2003). A prospective study of 100 consecutively presenting patients with acute abdominal conditions treated by the general surgical unit of Lagos University Teaching Hospital was undertaken. All patients had supine and erect abdominal x-ray before any therapeutic intervention was undertaken. The diagnostic features of the plain films were compared with final diagnosis to determine the usefulness of the plain x-ray There were 54 males and 46 females (M:F 1.2:1). Twenty-four percent of the patients had intestinal obstruction, 20% perforated typhoid enteritis; gunshot injuries and generalized peritonitis each occurred in 13%, blunt abdominal trauma in 12%, while 8% and 10% had acute appendicitis and perforated peptic ulcer disease respectively. Of 100 patients studied, 54% had plain abdominal radiographs that showed positive diagnostic features. Plain abdominal radiograph showed high sensitivity in patients with intestinal obstruction 100% and perforated peptic ulcer 90% but was less sensitive in patients with perforated typhoid, acute appendicitis, and blunt abdominal trauma and generalized peritonitis. In conclusion, this study

  17. Evaluation of the levels of metalloproteinsase-2 in patients with abdominal aneurysm and abdominal hernias.

    PubMed

    Antoszewska, Magdalena

    2013-05-01

    Abdominal aortic aneurysms and abdominal hernias become an important health problems of our times. Abdominal aortic aneurysm and its rupture is one of the most dangerous fact in vascular surgery. There are some theories pointing to a multifactoral genesis of these kinds of diseases, all of them assume the attenuation of abdominal fascia and abdominal aortic wall. The density and continuity of these structures depend on collagen and elastic fibers structure. Reducing the strength of the fibers may be due to changes in the extracellular matrix (ECM) by the proteolytic enzymes-matrix metalloproteinases (MMPs) that degrade extracellular matrix proteins. These enzymes play an important role in the development of many disease: malignant tumors (colon, breast, lung, pancreas), cardiovascular disease (myocardial infarction, ischemia-reperfusion injury), connective tissue diseases (Ehler-Danlos Syndrome, Marfan's Syndrome), complications of diabetes (retinopathy, nephropathy). One of the most important is matrix metalloproteinase-2 (MMP-2). The aim of the study was an estimation of the MMP-2 blood levels in patients with abdominal aortic aneurysm and primary abdominal hernia, and in patients with only abdominal aortic aneurysm. The study involved 88 patients aged 42 to 89 years, including 75 men and 13 women. Patients were divided into two groups: patients with abdominal aortic aneurysm and primary abdominal hernia (45 persons, representing 51.1% of all group) and patients with only abdominal aortic aneurysm (43 persons, representing 48,9% of all group). It was a statistically significant increase in MMP-2 blood levels in patients with abdominal aortic aneurysm and primary abdominal hernia compared to patients with only abdominal aortic aneurysm. It was a statistically significant increase in the prevalence of POCHP in patients with only abdominal aortic aneurysm compared to patients with abdominal aortic aneurysm and primary abdominal hernia. Statistically significant

  18. Selective cerebral perfusion prevents abnormalities in glutamate cycling and neuronal apoptosis in a model of infant deep hypothermic circulatory arrest and reperfusion.

    PubMed

    Kajimoto, Masaki; Ledee, Dolena R; Olson, Aaron K; Isern, Nancy G; Robillard-Frayne, Isabelle; Des Rosiers, Christine; Portman, Michael A

    2016-11-01

    Deep hypothermic circulatory arrest is often required for the repair of complex congenital cardiac defects in infants. However, deep hypothermic circulatory arrest induces neuroapoptosis associated with later development of neurocognitive abnormalities. Selective cerebral perfusion theoretically provides superior neural protection possibly through modifications in cerebral substrate oxidation and closely integrated glutamate cycling. We tested the hypothesis that selective cerebral perfusion modulates glucose utilization, and ameliorates abnormalities in glutamate flux, which occur in association with neuroapoptosis during deep hypothermic circulatory arrest. Eighteen infant male Yorkshire piglets were assigned randomly to two groups of seven (deep hypothermic circulatory arrest or deep hypothermic circulatory arrest with selective cerebral perfusion for 60 minutes at 18℃) and four control pigs without cardiopulmonary bypass support. Carbon-13-labeled glucose as a metabolic tracer was infused, and gas chromatography-mass spectrometry and nuclear magnetic resonance were used for metabolic analysis in the frontal cortex. Following 2.5 h of cerebral reperfusion, we observed similar cerebral adenosine triphosphate levels, absolute levels of lactate and citric acid cycle intermediates, and carbon-13 enrichment among three groups. However, deep hypothermic circulatory arrest induced significant abnormalities in glutamate cycling resulting in reduced glutamate/glutamine and elevated γ-aminobutyric acid/glutamate along with neuroapoptosis, which were all prevented by selective cerebral perfusion. The data suggest that selective cerebral perfusion prevents these modifications in glutamate/glutamine/γ-aminobutyric acid cycling and protects the cerebral cortex from apoptosis. © The Author(s) 2016.

  19. Is heart transplantation after circulatory death compatible with the dead donor rule?

    PubMed

    Nair-Collins, Michael; Miller, Franklin G

    2016-05-01

    Dalle Ave et al (2016) provide a valuable overview of several protocols for heart transplantation after circulatory death. However, their analysis of the compatibility of heart donation after circulatory death (DCD) with the dead donor rule (DDR) is flawed. Their permanence-based criteria for death, which depart substantially from established law and bioethics, are ad hoc and unfounded. Furthermore, their analysis is self-defeating, because it undercuts the central motivation for DDR as both a legal and a moral constraint, rendering the DDR vacuous and trivial. Rather than devise new and ad hoc criteria for death for the purpose of rendering DCD nominally consistent with DDR, we contend that the best approach is to explicitly abandon DDR. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  20. [A commonly seen cause of abdominal pain: abdominal cutaneous nerve entrapment syndrome].

    PubMed

    Solmaz, Ilker; Talay, Mustafa; Tekindur, Şükrü; Kurt, Ercan

    2012-01-01

    Although abdominal cutaneous nerve entrapment syndrome (ACNES) is accepted as a rare condition, it is a syndrome that should be diagnosed more commonly when the clinical signs cannot explain the cause of abdominal pain. Abdominal pain is commonly considered by physicians to be based on intra-abdominal causes. Consequently, redundant tests and consultations are requested for these patients, and unnecessary surgical procedures may be applied. Patients with this type of pain are consulted to many clinics, and because their definitive diagnoses cannot be achieved, they are assessed as psychiatric patients. Actually, a common cause of abdominal wall pain is nerve entrapment on the lateral edge of the rectus abdominis muscle. In this paper, we would like to share information about the diagnosis and treatment of a patient who, prior to presenting to us, had applied to different clinics for chronic abdominal pain and had undergone many tests and consultations; abdominal surgery was eventually decided.

  1. Ethical controversies in organ donation after circulatory death.

    PubMed

    2013-05-01

    The persistent mismatch between the supply of and need for transplantable organs has led to efforts to increase the supply, including controlled donation after circulatory death (DCD). Controlled DCD involves organ recovery after the planned withdrawal of life-sustaining treatment and the declaration of death according to the cardiorespiratory criteria. Two central ethical issues in DCD are when organ recovery can begin and how to manage conflicts of interests. The "dead donor rule" should be maintained, and donors in cases of DCD should only be declared dead after the permanent cessation of circulatory function. Permanence is generally established by a 2- to 5-minute waiting period. Given ongoing controversy over whether the cessation must also be irreversible, physicians should not be required to participate in DCD. Because the preparation for organ recovery in DCD begins before the declaration of death, there are potential conflicts between the donor's and recipient's interests. These conflicts can be managed in a variety of ways, including informed consent and separating the various participants' roles. For example, informed consent should be sought for premortem interventions to improve organ viability, and organ procurement organization personnel and members of the transplant team should not be involved in the discontinuation of life-sustaining treatment or the declaration of death. It is also important to emphasize that potential donors in cases of DCD should receive integrated interdisciplinary palliative care, including sedation and analgesia.

  2. Measurement of mean circulatory filling pressure and vascular compliance in domestic pigs.

    PubMed

    Ogilvie, R I; Zborowska-Sluis, D; Tenaschuk, B

    1990-06-01

    To measure mean circulatory filling pressure (Pmcf), a balloon was placed in the right atrium of seven pentobarbital sodium-anesthetized open-chest pigs for transient occlusion of flow combined with mechanical transfer of blood from the arterial to the venous circulation. Equilibration occurred within 6-8 s at a pressure at 12.3 +/- 0.3 (SE) mmHg after a 2.9 +/- 0.2 ml/kg transfer of blood. In another group of pentobarbital sodium-anesthetized closed-chest pigs, acetylcholine (ACh) was used to induce cardiac arrest. The Pmcf was 11.6 +/- 1.0 mmHg in the 7:17 pigs that arrested for 6-8 s. In four isoflurane-anesthetized closed-chest pigs, the Pmcf was 12.0 +/- 1.0 mmHg after terminal cardiac arrest induced by KCl. The pressure gradient for venous return [Pmcf--right atrial pressure (Pra)] averaged 5.9 +/- 0.2 mmHg. Total vascular compliance estimated from plots of Pmcf at base line, 5, and 10 ml/kg increases in circulating volume was 2.1 +/- 0.3 and 3.5 +/- 0.9 ml.kg-1.mmHg-1 in the balloon and ACh groups, respectively compared with 2.8 +/- 0.4 ml.kg-1.mmHg-1 using a volume infusion-withdrawal method without circulatory arrest. The use of ACh for the estimate of Pmcf in the pig is not recommended because of failure to consistently induce circulatory arrest and probable failure to achieve sufficient equilibrium of vascular pressures 6-8 s postarrest when it occurs.

  3. Computational Hemodynamic Simulation of Human Circulatory System under Altered Gravity

    NASA Technical Reports Server (NTRS)

    Kim. Chang Sung; Kiris, Cetin; Kwak, Dochan

    2003-01-01

    A computational hemodynamics approach is presented to simulate the blood flow through the human circulatory system under altered gravity conditions. Numerical techniques relevant to hemodynamics issues are introduced to non-Newtonian modeling for flow characteristics governed by red blood cells, distensible wall motion due to the heart pulse, and capillary bed modeling for outflow boundary conditions. Gravitational body force terms are added to the Navier-Stokes equations to study the effects of gravity on internal flows. Six-type gravity benchmark problems are originally presented to provide the fundamental understanding of gravitational effects on the human circulatory system. For code validation, computed results are compared with steady and unsteady experimental data for non-Newtonian flows in a carotid bifurcation model and a curved circular tube, respectively. This computational approach is then applied to the blood circulation in the human brain as a target problem. A three-dimensional, idealized Circle of Willis configuration is developed with minor arteries truncated based on anatomical data. Demonstrated is not only the mechanism of the collateral circulation but also the effects of gravity on the distensible wall motion and resultant flow patterns.

  4. Theological reflections on donation after circulatory death: the wisdom of Paul Ramsey and Moshe Feinstein.

    PubMed

    Jotkowitz, A

    2008-10-01

    Due to the worldwide shortage of organs for transplantation, there has been an increased use of organs obtained after circulatory death alone. A protocol for this procedure has recently been approved by a major transplant consortium. This development raises serious moral and ethical concerns. Two renowned theologians of the previous generation, Paul Ramsey and Moshe Feinstein, wrote extensively on the ethical issues relating to transplantation, and their work has much relevance to current moral dilemmas. Their writings relating to definition of death, organ transplantation and the care of the terminally ill are briefly presented, and their potential application to the moral problem of organ donation after circulatory death is discussed.

  5. PREVENtion of HeartMate II Pump Thrombosis Through Clinical Management: The PREVENT multi-center study.

    PubMed

    Maltais, Simon; Kilic, Ahmet; Nathan, Sriram; Keebler, Mary; Emani, Sitaramesh; Ransom, John; Katz, Jason N; Sheridan, Brett; Brieke, Andreas; Egnaczyk, Gregory; Entwistle, John W; Adamson, Robert; Stulak, John; Uriel, Nir; O'Connell, John B; Farrar, David J; Sundareswaran, Kartik S; Gregoric, Igor

    2017-01-01

    Recommended structured clinical practices including implant technique, anti-coagulation strategy, and pump speed management (PREVENT [PREVENtion of HeartMate II Pump Thrombosis Through Clinical Management] recommendations) were developed to address risk of early (<3 months) pump thrombosis (PT) risk with HeartMate II (HMII; St. Jude Medical, Inc. [Thoratec Corporation], Pleasanton, CA). We prospectively assessed the HMII PT rate in the current era when participating centers adhered to the PREVENT recommendations. PREVENT was a prospective, multi-center, single-arm, non-randomized study of 300 patients implanted with HMII at 24 participating sites. Confirmed PT (any suspected PT confirmed visually and/or adjudicated by an independent assessor) was evaluated at 3 months (primary end-point) and at 6 months after implantation. The population included 83% men (age 57 years ± 13), 78% destination therapy, and 83% Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) Profile 1-3. Primary end-point analysis showed a confirmed PT of 2.9% at 3 months and 4.8% at 6 months. Adherence to key recommendations included 78% to surgical recommendations, 95% to heparin bridging, and 79% to pump speeds ≥9,000 RPMs (92% >8,600 RPMs). Full adherence to implant techniques, heparin bridging, and pump speeds ≥9,000 RPMs resulted in a significantly lower risk of PT (1.9% vs 8.9%; p < 0.01) and lower composite risk of suspected thrombosis, hemolysis, and ischemic stroke (5.7% vs 17.7%; p < 0.01) at 6 months. Adoption of all components of a structured surgical implant technique and clinical management strategy (PREVENT recommendations) is associated with low rates of confirmed PT. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  6. Does the arterial cannulation site for circulatory arrest influence stroke risk?

    PubMed

    Svensson, Lars G; Blackstone, Eugene H; Rajeswaran, Jeevanantham; Sabik, Joseph F; Lytle, Bruce W; Gonzalez-Stawinski, Gonzalo; Varvitsiotis, Poseidon; Banbury, Michael K; McCarthy, Patrick M; Pettersson, Gösta B; Cosgrove, Delos M

    2004-10-01

    We investigated whether axillary/subclavian artery inflow with a side graft decreases the risk of stroke versus cannulation at other sites during hypothermic circulatory arrest. Between January 1993 and May 2003, 1,352 operations with circulatory arrest were performed for complex adult cardiac problems. A single arterial inflow cannulation site was used in 1,336 operations, and these formed the basis for comparative analyses. Cannulation sites were axillary plus graft in 299 operations, direct cannulation of the aorta in 471, femoral in 375, innominate in 24, and axillary or subclavian without a side graft in 167. Retrograde brain perfusion was used in 933 (69%). A total of 272 (20%) were for emergencies, 432 (32%) were reoperations, and 439 (32%) were for dissections. A total of 617 (46%) had aortic valve replacement and 1,160 (87%) ascending, 415 arch (31%), and 248 descending (18%) aortic replacements. Indications also included arteriosclerosis (n = 301) and calcified aorta (n = 278). Primary comparisons were made by using propensity matching, and, secondarily, risk factors for stroke or hospital mortality were identified by multivariable logistic regression. Stroke occurred in 6.1% of patients (81/1,336): 4.0% (12/299) of those had axillary plus graft and 6.7% who had direct cannulation (69/1,037; p = 0.09; p = 0.05 among propensity-matched pairs). Operative variables associated with stroke included direct aortic cannulation, aortic arteriosclerosis, descending aorta repair, and mitral valve replacement. The risk of hospital mortality was higher (11%; 42/375) for patients who had femoral cannulation than axillary plus graft (7.0%; 21/299; p = 0.06; p = 0.02 among propensity-matched pairs). Axillary inflow plus graft reduces stroke and is our method of choice for complex cardiac and cardioaortic operations that necessitate circulatory arrest. Retrograde or antegrade perfusion is used selectively.

  7. Experimental and numeric investigation of Impella pumps as cavopulmonary assistance for a failing Fontan.

    PubMed

    Haggerty, Christopher M; Fynn-Thompson, Francis; McElhinney, Doff B; Valente, Anne Marie; Saikrishnan, Neelakantan; Del Nido, Pedro J; Yoganathan, Ajit P

    2012-09-01

    This study sought to evaluate the performance of microaxial ventricular assist devices for the purposes of supporting failing Fontan physiology by decreasing central venous pressure. Three Abiomed Impella pumps (Abiomed, Inc, Danvers, Mass) were evaluated in a mock circulatory system of the Fontan circuit. The local response of pressures and flows to pump function was assessed as a function of pump speed and pulmonary vascular resistance at a high baseline central venous pressure. For one device, subsequent modeling studies were conducted using a lumped parameter model of the single ventricle circuit. The left ventricular devices (Impella 2.5, 5.0) were shown to be suboptimal as single device solutions for cavopulmonary support. The small area of these devices relative to vessel diameter led to significant flow recirculation without an obstructive separator in place. Furthermore, downstream pressure augmentation adversely affected the pressure in the superior vena cava. The use of 2 devices would be mandatory for successful support. The right-sided device (Impella RP), whose outflow was positioned in the left pulmonary artery, demonstrated decreased flow recirculation and did not impede superior caval venous flow. Although static pressure is still required to drive flow through the opposite lung, numeric modeling demonstrated the potential for modest but significant improvements in lowering the central venous pressure (2-8 mm Hg). Left-sided microaxial pumps are not well suited for cavopulmonary support because of severe flow recirculation and the need for multiple devices. The right-ventricular Impella device provides improved performance by directing flow into the pulmonary artery, resulting in modest decreases in central venous pressure. Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  8. Focused abdominal sonography for trauma (FAST) in blunt paediatric abdominal trauma.

    PubMed

    Faruque, Ahmad Vaqas; Qazi, Saqib Hamid; Khan, Muhammad Arif Mateen; Akhtar, Wassem; Majeed, Amina

    2013-03-01

    To evaluate the role of focussed abdominal sonography for trauma in blunt paediatric abdominal trauma patients, and to see if the role of computed tomography scan could be limited to only those cases in which sonography was positive. The retrospective study covered 10 years, from January 1,2000 to December 31,2009, and was conducted at the Department of Radiology and Department of Emergency Medicine, Aga Khan University Hospital, Karachi. It comprised cases of 174 children from birth to 14 years who had presented with blunt abdominal trauma and had focussed abdominal sonography for trauma done at the hospital. The findings were correlated with computed tomography scan of the abdomen and clinical follow-up. Sensitivity, specificity, positive predictive value, negative predictive value and accuracy of focussed abdominal sonography for trauma were calculated for blunt abdominal trauma. SPSS 17 was used for statistical analysis. Of the total 174 cases, 31 (17.81%) were later confirmed by abdominal scan. Of these 31 children, sonography had been positive in 29 (93.54%) children. In 21 (67.74%) of the 31 children, sonograpy had been true positive; 8 (25%) (8/31) were false positive; and 2 (6%) (2/31) were false negative. There were 6 (19.3%) children in which sonography was positive and converted to laparotomy. There was no significant difference on account of gender (p>0.356). Focussed abdominal sonography for trauma in the study had sensitivity of 91%, specificity of 95%, positive predictive value of 73%, and negative predictive value of 73% with accuracy of 94%. All patients who had negative sonography were discharged later, and had no complication on clinical follow-up. Focussed abdominal sonography for trauma is a fairly reliable mode to assess blunt abdominal trauma in children. It is a useful tool to pick high-grade solid and hollow viscous injury. The results suggest that the role of computed tomography scan can be limited to those cases in which focussed

  9. Influence of exercise training on the oxidative capacity of rat abdominal muscles

    NASA Technical Reports Server (NTRS)

    Uribe, J. M.; Stump, C. S.; Tipton, C. M.; Fregosi, R. F.

    1992-01-01

    Our purpose was to determine if endurance exercise training would increase the oxidative capacity of the abdominal expiratory muscles of the rat. Accordingly, 9 male rats were subjected to an endurance training protocol (1 h/day, 6 days/week, 9 weeks) and 9 litter-mates served as controls. Citrate synthase (CS) activity was used as an index of oxidative capacity, and was determined in the following muscles: soleus, plantaris, costal diaphragm, crural diaphragm, and in all four abdominal muscles: rectus abdominis, transversus abdominis, external oblique, and internal oblique. Compared to their non-trained litter-mates, the trained rats had higher peak whole body oxygen consumption rates (+ 16%) and CS activities in plantaris (+34%) and soleus (+36%) muscles. Thus, the training program caused substantial systemic and locomotor muscle adaptations. The CS activity of costal diaphragm was 20% greater in the trained animals, but no difference was observed in crural diaphragm. The CS activity in the abdominal muscles was less than one-half of that in locomotor and diaphragm muscles, and there were no significant changes with training except in the rectus abdominis where a 26% increase was observed. The increase in rectus abdominis CS activity may reflect its role in postural support and/or locomotion, as none of the primary expiratory pumping muscles adapted to the training protocol. The relatively low levels of CS activity in the abdominal muscles suggests that they are not recruited frequently at rest, and the lack of an increase with training indicates that these muscles do not contribute significantly to the increased ventilatory activity accompanying exercise in the rat.

  10. Effect of intra-aortic balloon pump on coronary blood flow during different balloon cycles support: A computer study.

    PubMed

    Aye, Thin Pa Pa; Htet, Zwe Lin; Singhavilai, Thamvarit; Naiyanetr, Phornphop

    2015-01-01

    Intra-aortic balloon pump (IABP) has been used in clinical treatment as a mechanical circulatory support device for patients with heart failure. A computer model is used to study the effect on coronary blood flow (CBF) with different balloon cycles under both normal and pathological conditions. The model of cardiovascular and IABP is developed by using MATLAB SIMULINK. The effect on coronary blood flow has been studied under both normal and pathological conditions using different balloon cycles (balloon off; 1:4; 1:2; 1:1). A pathological heart is implemented by reducing the left ventricular contractility. The result of this study shows that the rate of balloon cycles is related to the level of coronary blood flow.

  11. Child with Abdominal Pain.

    PubMed

    Iyer, Rajalakshmi; Nallasamy, Karthi

    2018-01-01

    Abdominal pain is one of the common symptoms reported by children in urgent care clinics. While most children tend to have self-limiting conditions, the treating pediatrician should watch out for underlying serious causes like intestinal obstruction and perforation peritonitis, which require immediate referral to an emergency department (ED). Abdominal pain may be secondary to surgical or non-surgical causes, and will differ as per the age of the child. The common etiologies for abdominal pain presenting to an urgent care clinic are acute gastro-enteritis, constipation and functional abdominal pain; however, a variety of extra-abdominal conditions may also present as abdominal pain. Meticulous history taking and physical examination are the best tools for diagnosis, while investigations have a limited role in treating benign etiologies.

  12. Heart Transplant and Mechanical Circulatory Support in Patients With Advanced Heart Failure.

    PubMed

    Sánchez-Enrique, Cristina; Jorde, Ulrich P; González-Costello, José

    2017-05-01

    Patients with advanced heart failure have a poor prognosis and heart transplant is still the best treatment option. However, the scarcity of donors, long waiting times, and an increasing number of unstable patients have favored the development of mechanical circulatory support. This review summarizes the indications for heart transplant, candidate evaluation, current immunosuppression strategies, the evaluation and treatment of rejection, infectious prophylaxis, and short and long-term outcomes. Regarding mechanical circulatory support, we distinguish between short- and long-term support and the distinct strategies that can be used: bridge to decision, recovery, candidacy, transplant, and destination therapy. We then discuss indications, risk assessment, management of complications, especially with long-term support, and outcomes. Finally, we discuss future challenges and how the widespread use of long-term support for patients with advanced heart failure will only be viable if their complications and costs are reduced. Copyright © 2017 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  13. Bilingual Skills Training Program. Barbering/Cosmetology. Module 10.0: Circulatory System.

    ERIC Educational Resources Information Center

    Northern New Mexico Community Coll., El Rito.

    This module on the circulatory or vascular system is the tenth of ten (CE 028 308-318) in the barbering/cosmetology course of a bilingual skills training program. (A Vocabulary Development Workbook for modules 6-10 is available as CE 028 313.) The course is designed to furnish theoretical and laboratory experience. Module objectives are for…

  14. Development and Validation of a Two-Tier Instrument to Examine Understanding of Internal Transport in Plants and the Human Circulatory System

    ERIC Educational Resources Information Center

    Wang, Jing-Ru

    2004-01-01

    This study is intended to develop an assessment instrument to investigate students' understandings about internal transport in plants and human circulatory system. A refined process of a two-tier diagnostic test was used to develop the instrument. Finally, three versions of the Internal Transport in Plants and the Human Circulatory System test…

  15. Abdominal wall fat pad biopsy

    MedlinePlus

    Amyloidosis - abdominal wall fat pad biopsy; Abdominal wall biopsy; Biopsy - abdominal wall fat pad ... most common method of taking an abdominal wall fat pad biopsy . The health care provider cleans the ...

  16. Development of a numerical pump testing framework.

    PubMed

    Kaufmann, Tim A S; Gregory, Shaun D; Büsen, Martin R; Tansley, Geoff D; Steinseifer, Ulrich

    2014-09-01

    It has been shown that left ventricular assist devices (LVADs) increase the survival rate in end-stage heart failure patients. However, there is an ongoing demand for an increased quality of life, fewer adverse events, and more physiological devices. These challenges necessitate new approaches during the design process. In this study, computational fluid dynamics (CFD), lumped parameter (LP) modeling, mock circulatory loops (MCLs), and particle image velocimetry (PIV) are combined to develop a numerical Pump Testing Framework (nPTF) capable of analyzing local flow patterns and the systemic response of LVADs. The nPTF was created by connecting a CFD model of the aortic arch, including an LVAD outflow graft to an LP model of the circulatory system. Based on the same geometry, a three-dimensional silicone model was crafted using rapid prototyping and connected to an MCL. PIV studies of this setup were performed to validate the local flow fields (PIV) and the systemic response (MCL) of the nPTF. After validation, different outflow graft positions were compared using the nPTF. Both the numerical and the experimental setup were able to generate physiological responses by adjusting resistances and systemic compliance, with mean aortic pressures of 72.2-132.6 mm Hg for rotational speeds of 2200-3050 rpm. During LVAD support, an average flow to the distal branches (cerebral and subclavian) of 24% was found in the experiments and the nPTF. The flow fields from PIV and CFD were in good agreement. Numerical and experimental tools were combined to develop and validate the nPTF, which can be used to analyze local flow fields and the systemic response of LVADs during the design process. This allows analysis of physiological control parameters at early development stages and may, therefore, help to improve patient outcomes. Copyright © 2014 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  17. Capturing in situ skeletal muscle power for circulatory support: a new approach to device design.

    PubMed

    Trumble, Dennis R; Magovern, James A

    2003-01-01

    Efforts to harness in situ skeletal muscle for circulatory support have been extensive, but implants designed to tap this power source have yet to meet the strict performance standards incumbent upon such devices. A fourth generation muscle energy converter (MEC4) is described that represents a significant departure from previous hydraulic muscle pump designs, all of which have assumed a long cylindrical profile. The MEC4, in contrast, features a puck shaped metallic bellows oriented so that its end fittings lie parallel to the chest wall. The fixed end is centered over a fluid port that passes into the thoracic cavity across one resected rib. The opposite end of the bellows supports a roller bearing that moves beneath a linear cam fixed to a reciprocating shaft. The shaft exits the housing through a spring loaded seal and is attached to a sintered anchor pad for muscle tendon fixation. This configuration was chosen to improve bellows durability, lower device profile, and reduce tissue encumbrance to actuator recoil. Bench tests show that modest actuation forces can effect full actuator displacement in 0.25 seconds against high pressure loads, transmitting up to 0.9 J/stroke at 60% efficiency. In vitro tests also confirm that key device performance parameters can be computed from pressure readings transmitted via radiotelemetry, clearing the way for long-term implant studies in conscious animals.

  18. [Circulatory Function Tests for Home & Community Use.

    PubMed

    Shimetani, Naoto

    2016-05-01

    Currently, the main circulatory function-testing tools for home use are blood pressure monitors and elec- trocardiography devices. Just like blood pressure monitors that are already widespread for home use, some devices with an electrocardiographic function have recently become available for purchase for personal use by the general public. On the other hand, clinic equipment on loan from doctors to patients in need can perform circulatory function tests like 24-hour ambulatory blood pressure monitoring (ABPM), Holter monitoring, and real-time electrocardiography. We introduce the actual clinical usage of ABPM and real-time electro- cardiography, and discuss the usefulness of these procedures. ABPM uses a blood pressure measurement device worn on the body for 24 hours a day to measure blood pressure at regular intervals. This makes it possible to check blood pressure changes throughout the day in a way in which conventional home-use blood pressure monitors cannot, like during sleep. This method al- lows the identification of masked hypertension like early-morning and nocturnal hypertension, stress hyper- tension including workplace hypertension, and white coat hypertension that only occurs in the doctor's office. Under routine care, there are few opportunities to perform electrocardiography at the time a patient is experiencing symptoms. Now, real-time electrocardiography has begun to be used in routine care, and pa- tients can record an electrocardiogram by themselves anytime, anywhere, and send the data by telephone or the Internet for analysis and diagnosis. Transmission-capable electrocardiography devices can play an im- portant role in the event of dangerous symptoms like arrhythmia, angina, or acute myocardial infarction. The spread of ABPM and event heart monitors is likely to make the early treatment and prevention of stroke and heart disease possible. We are expecting rapid development in this field in the future.

  19. Snake constriction rapidly induces circulatory arrest in rats.

    PubMed

    Boback, Scott M; McCann, Katelyn J; Wood, Kevin A; McNeal, Patrick M; Blankenship, Emmett L; Zwemer, Charles F

    2015-07-01

    As legless predators, snakes are unique in their ability to immobilize and kill their prey through the process of constriction, and yet how this pressure incapacitates and ultimately kills the prey remains unknown. In this study, we examined the cardiovascular function of anesthetized rats before, during and after being constricted by boas (Boa constrictor) to examine the effect of constriction on the prey's circulatory function. The results demonstrate that within 6 s of being constricted, peripheral arterial blood pressure (PBP) at the femoral artery dropped to 1/2 of baseline values while central venous pressure (CVP) increased 6-fold from baseline during the same time. Electrocardiographic recordings from the anesthetized rat's heart revealed profound bradycardia as heart rate (fH) dropped to nearly half of baseline within 60 s of being constricted, and QRS duration nearly doubled over the same time period. By the end of constriction (mean 6.5±1 min), rat PBP dropped 2.9-fold, fH dropped 3.9-fold, systemic perfusion pressure (SPP=PBP-CVP) dropped 5.7-fold, and 91% of rats (10 of 11) had evidence of cardiac electrical dysfunction. Blood drawn immediately after constriction revealed that, relative to baseline, rats were hyperkalemic (serum potassium levels nearly doubled) and acidotic (blood pH dropped from 7.4 to 7.0). These results are the first to document the physiological response of prey to constriction and support the hypothesis that snake constriction induces rapid prey death due to circulatory arrest. © 2015. Published by The Company of Biologists Ltd.

  20. 18. Electrically driven pumps in Armory Street Pump House. Pumps ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    18. Electrically driven pumps in Armory Street Pump House. Pumps in background formerly drew water from the clear well. They went out of service when use of the beds was discontinued. Pumps in the foreground provide high pressure water to Hamden. - Lake Whitney Water Filtration Plant, Armory Street Pumphouse, North side of Armory Street between Edgehill Road & Whitney Avenue, Hamden, New Haven County, CT

  1. Unexplained abdominal pain as a driver for inappropriate therapeutics: an audit on the use of intravenous proton pump inhibitors

    PubMed Central

    Wong, Yin Yen; Low, Yong Chia; Lau, Hui Ling; Chin, Kin-Fah; Mahadeva, Sanjiv

    2014-01-01

    Background. Proton pump inhibitors (PPIs) are currently the most effective agents for acid-related disorders. However, studies show that 25–75% of patients receiving intravenous PPIs had no appropriate justification, indicating high rates of inappropriate prescribing. Objective. To examine the appropriate use of intravenous PPIs in accordance with guidelines and the efficacy of a prescribing awareness intervention at an Asian teaching institution. Setting. Prospective audit in a tertiary hospital in Malaysia. Method. Every 4th intravenous PPI prescription received in the pharmacy was screened against hospital guidelines. Interventions for incorrect indication/dose/duration were performed. Patients’ demographic data, medical history and the use of intravenous PPI were collected. Included were all adult inpatients prescribed intravenous PPI. Main Outcome Measure. Proportion of appropriate IV PPI prescriptions. Results. Data for 106 patients were collected. Most patients were male [65(61.3%)], Chinese [50(47.2%)], with mean age ± SD = 60.3 ± 18.0 years. Most intravenous PPI prescriptions were initiated by junior doctors from the surgical [47(44.3%)] and medical [42(39.6%)] departments. Only 50/106(47.2%) patients had upper gastrointestinal endoscopy/surgery performed to verify the source of bleeding. Unexplained abdominal pain [81(76.4%)] was the main driver for prescribing intravenous PPIs empirically, out of which 73(68.9%) were for suspected upper gastrointestinal bleed. Overall, intravenous PPI was found to be inappropriately prescribed in 56(52.8%) patients for indication, dose or duration. Interventions on the use of intravenous PPI were most effective when performed by senior doctors (100%), followed by clinical pharmacists (50%), and inpatient pharmacists (37.5%, p = 0.027). Conclusion. Inappropriate intravenous PPI usage is still prevalent despite the enforcement of hospital guidelines. The promotion of prescribing awareness and evidence

  2. Unexplained abdominal pain as a driver for inappropriate therapeutics: an audit on the use of intravenous proton pump inhibitors.

    PubMed

    Lai, Pauline Siew Mei; Wong, Yin Yen; Low, Yong Chia; Lau, Hui Ling; Chin, Kin-Fah; Mahadeva, Sanjiv

    2014-01-01

    Background. Proton pump inhibitors (PPIs) are currently the most effective agents for acid-related disorders. However, studies show that 25-75% of patients receiving intravenous PPIs had no appropriate justification, indicating high rates of inappropriate prescribing. Objective. To examine the appropriate use of intravenous PPIs in accordance with guidelines and the efficacy of a prescribing awareness intervention at an Asian teaching institution. Setting. Prospective audit in a tertiary hospital in Malaysia. Method. Every 4th intravenous PPI prescription received in the pharmacy was screened against hospital guidelines. Interventions for incorrect indication/dose/duration were performed. Patients' demographic data, medical history and the use of intravenous PPI were collected. Included were all adult inpatients prescribed intravenous PPI. Main Outcome Measure. Proportion of appropriate IV PPI prescriptions. Results. Data for 106 patients were collected. Most patients were male [65(61.3%)], Chinese [50(47.2%)], with mean age ± SD = 60.3 ± 18.0 years. Most intravenous PPI prescriptions were initiated by junior doctors from the surgical [47(44.3%)] and medical [42(39.6%)] departments. Only 50/106(47.2%) patients had upper gastrointestinal endoscopy/surgery performed to verify the source of bleeding. Unexplained abdominal pain [81(76.4%)] was the main driver for prescribing intravenous PPIs empirically, out of which 73(68.9%) were for suspected upper gastrointestinal bleed. Overall, intravenous PPI was found to be inappropriately prescribed in 56(52.8%) patients for indication, dose or duration. Interventions on the use of intravenous PPI were most effective when performed by senior doctors (100%), followed by clinical pharmacists (50%), and inpatient pharmacists (37.5%, p = 0.027). Conclusion. Inappropriate intravenous PPI usage is still prevalent despite the enforcement of hospital guidelines. The promotion of prescribing awareness and evidence-based prescribing

  3. Nitroglycerin reverts clinical manifestations of poor peripheral perfusion in patients with circulatory shock.

    PubMed

    Lima, Alexandre; van Genderen, Michel E; van Bommel, Jasper; Klijn, Eva; Jansem, Tim; Bakker, Jan

    2014-06-19

    Recent clinical studies have shown a relationship between abnormalities in peripheral perfusion and unfavorable outcome in patients with circulatory shock. Nitroglycerin is effective in restoring alterations in microcirculatory blood flow. The aim of this study was to investigate whether nitroglycerin could correct the parameters of abnormal peripheral circulation in resuscitated circulatory shock patients. This interventional study recruited patients who had circulatory shock and who persisted with abnormal peripheral perfusion despite normalization of global hemodynamic parameters. Nitroglycerin started at 2 mg/hour and doubled stepwise (4, 8, and 16 mg/hour) each 15 minutes until an improvement in peripheral perfusion was observed. Peripheral circulation parameters included capillary refill time (CRT), skin-temperature gradient (Tskin-diff), perfusion index (PI), and tissue oxygen saturation (StO2) during a reactive hyperemia test (RincStO2). Measurements were performed before, at the maximum dose, and after cessation of nitroglycerin infusion. Data were analyzed by using linear model for repeated measurements and are presented as mean (standard error). Of the 15 patients included, four patients (27%) responded with an initial nitroglycerin dose of 2 mg/hour. In all patients, nitroglycerin infusion resulted in significant changes in CRT, Tskin-diff, and PI toward normal at the maximum dose of nitroglycerin: from 9.4 (0.6) seconds to 4.8 (0.3) seconds (P < 0.05), from 3.3 °C (0.7 °C) to 0.7 °C (0.6 °C) (P < 0.05), and from [log] -0.5% (0.2%) to 0.7% (0.1%) (P < 0.05), respectively. Similar changes in StO2 and RincStO2 were observed: from 75% (3.4%) to 84% (2.7%) (P < 0.05) and 1.9%/second (0.08%/second) to 2.8%/second (0.05%/second) (P < 0.05), respectively. The magnitude of changes in StO2 was more pronounced for StO2 of less than 75%: 11% versus 4%, respectively (P < 0.05). Dose-dependent infusion of nitroglycerin reverted abnormal peripheral perfusion and

  4. Don't Forget the Abdominal Wall: Imaging Spectrum of Abdominal Wall Injuries after Nonpenetrating Trauma.

    PubMed

    Matalon, Shanna A; Askari, Reza; Gates, Jonathan D; Patel, Ketan; Sodickson, Aaron D; Khurana, Bharti

    2017-01-01

    Abdominal wall injuries occur in nearly one of 10 patients coming to the emergency department after nonpenetrating trauma. Injuries range from minor, such as abdominal wall contusion, to severe, such as abdominal wall rupture with evisceration of abdominal contents. Examples of specific injuries that can be detected at cross-sectional imaging include abdominal muscle strain, tear, or hematoma, including rectus sheath hematoma (RSH); traumatic abdominal wall hernia (TAWH); and Morel-Lavallée lesion (MLL) (closed degloving injury). These injuries are often overlooked clinically because of (a) a lack of findings at physical examination or (b) distraction by more-severe associated injuries. However, these injuries are important to detect because they are highly associated with potentially grave visceral and vascular injuries, such as aortic injury, and because their detection can lead to the diagnosis of these more clinically important grave traumatic injuries. Failure to make a timely diagnosis can result in delayed complications, such as bowel hernia with potential for obstruction or strangulation, or misdiagnosis of an abdominal wall neoplasm. Groin injuries, such as athletic pubalgia, and inferior costochondral injuries should also be considered in patients with abdominal pain after nonpenetrating trauma, because these conditions may manifest with referred abdominal pain and are often included within the field of view at cross-sectional abdominal imaging. Radiologists must recognize and report acute abdominal wall injuries and their associated intra-abdominal pathologic conditions to allow appropriate and timely treatment. © RSNA, 2017.

  5. Correlation between intra-abdominal pressure and pulmonary volumes after superior and inferior abdominal surgery.

    PubMed

    Cleva, Roberto de; Assumpção, Marianna Siqueira de; Sasaya, Flavia; Chaves, Natalia Zuniaga; Santo, Marco Aurelio; Fló, Claudia; Lunardi, Adriana C; Jacob Filho, Wilson

    2014-07-01

    Patients undergoing abdominal surgery are at risk for pulmonary complications. The principal cause of postoperative pulmonary complications is a significant reduction in pulmonary volumes (FEV1 and FVC) to approximately 65-70% of the predicted value. Another frequent occurrence after abdominal surgery is increased intra-abdominal pressure. The aim of this study was to correlate changes in pulmonary volumes with the values of intra-abdominal pressure after abdominal surgery, according to the surgical incision in the abdomen (superior or inferior). We prospectively evaluated 60 patients who underwent elective open abdominal surgery with a surgical time greater than 240 minutes. Patients were evaluated before surgery and on the 3rd postoperative day. Spirometry was assessed by maximal respiratory maneuvers and flow-volume curves. Intra-abdominal pressure was measured in the postoperative period using the bladder technique. The mean age of the patients was 56 ± 13 years, and 41.6% 25 were female; 50 patients (83.3%) had malignant disease. The patients were divided into two groups according to the surgical incision (superior or inferior). The lung volumes in the preoperative period showed no abnormalities. After surgery, there was a significant reduction in both FEV1 (1.6 ± 0.6 L) and FVC (2.0 ± 0.7 L) with maintenance of FEV1/FVC of 0.8 ± 0.2 in both groups. The maximum intra-abdominal pressure values were similar (p=0.59) for the two groups. There was no association between pulmonary volumes and intra-abdominal pressure measured in any of the groups analyzed. Our results show that superior and inferior abdominal surgery determines hypoventilation, unrelated to increased intra-abdominal pressure. Patients at high risk of pulmonary complications should receive respiratory care even if undergoing inferior abdominal surgery.

  6. Circulatory and respiratory effects of methoxyflurane in dogs: comparison of halothane.

    PubMed

    Steffey, E P; Farver, T B; Woliner, M J

    1984-12-01

    Circulatory and respiratory effects of 3 alveolar concentrations (representing 1.0, 1.5, and 2.0 times the minimal alveolar concentration, MAC) of methoxyflurane in O2 were compared with similar MAC multiples of halothane in O2. Eight adult mixed breed dogs that were healthy and nonmedicated were studied in cross-over fashion with both agents during conditions of controlled ventilation (CV; PaCO2 averaged 34 to 38 mm of Hg) and spontaneous ventilation (SV). When ventilation was controlled, methoxyflurane similar to halothane caused dose-related cardiovascular depression. Except for a greater heart rate and lesser stroke volume with methoxyflurane, little difference was noticed between the anesthetics at equivalent doses during CV. There was less dose-related circulatory depression during SV with both agents but particularly with methoxyflurane. During SV, PaCO2 increased progressively with increases in alveolar concentrations of methoxyflurane and halothane. Methoxyflurane caused significantly greater (P less than 0.05) hypoventilation than halothane only at 2.0 MAC. Except for a greater respiratory gas flow and inspiratory-expiratory gas flow ratio and a lesser inspiratory-expiratory time ratio with methoxyflurane, there was no anesthetic- or dose-response effect on respiratory variables.

  7. Successful bridge to transplant in a highly sensitized patient with a complicated pump pocket infection.

    PubMed

    McGee, Edwin C; Cotts, William; Tambur, Anat R; Friedewald, John; Kim, John; O'Connell, John; Wallace, Suzanne; McCarthy, Patrick M

    2008-05-01

    A 32-year-old man with doxorubicin-induced cardiomyopathy presented in cardiogenic shock. He underwent placement of a Novacor (WorldHeart, Inc., Oakland, CA) left ventricular assist device as a bridge to transplant. Post-operatively he developed a pump pocket infection and dehiscence of his abdominal wound with exposure of the pump. This was treated with irrigation and drainage, antibiotic bead placement and flap closure. Both pre- and post-operative panel-reactive antibodies (PRA) were elevated. He underwent desensitization with intravenous immune globulin (IVIg), rituximab, mycophenolate mofetil and pre-operative plasmapheresis. A donor heart was identified and found to be acceptable by virtual crossmatch. He was transplanted and is doing well with normal graft function at >1 year post-operatively.

  8. Delayed Referral Results in Missed Opportunities for Organ Donation After Circulatory Death.

    PubMed

    Krmpotic, Kristina; Payne, Clare; Isenor, Cynthia; Dhanani, Sonny

    2017-06-01

    Rates of organ donation and transplantation have steadily increased in the United States and Canada over the past decade, largely attributable to a notable increase in donation after circulatory death. However, the number of patients awaiting solid organ transplantation continues to remain much higher than the number of organs transplanted each year. The objective of this study was to determine the potential to increase donation rates further by identifying gaps in the well-established donation after circulatory death process in Ontario. Retrospective cohort study. Provincial organ procurement organization. Patients who died in designated donation hospitals within the province of Ontario, Canada between April 1, 2013, and March 31, 2015. None. Of 1,407 patient deaths following planned withdrawal of life-sustaining therapy, 54.0% (n = 760) were medically suitable for donation after circulatory death. In 438 cases where next of kin was approached, consent rates reached 47.5%. A total of 119 patients became actual organ donors. Only 66.2% (n = 503) of suitable patients were appropriately referred, resulting in 251 missed potential donors whose next of kin could not be approached regarding organ donation because referral occurred after initiation of withdrawal of life-sustaining therapy or not at all. The number of medically suitable patients who die within 2 hours of planned withdrawal of life-sustaining therapy is nearly six times higher than the number of actual organ donors, with the greatest loss of potential due to delayed referral until at the time of or after planned withdrawal of life-sustaining therapy. Intensive care teams are not meeting their ethical responsibility to recognize impending death and appropriately refer potential organ donors to the local organ procurement organization. In cases where patients had previously registered their consent decision, they were denied a healthcare right.

  9. Generalized derivation of the added-mass and circulatory forces for viscous flows

    NASA Astrophysics Data System (ADS)

    Limacher, Eric; Morton, Chris; Wood, David

    2018-01-01

    The concept of added mass arises from potential flow analysis and is associated with the acceleration of a body in an inviscid irrotational fluid. When shed vorticity is modeled as vortex singularities embedded in this irrotational flow, the associated force can be superimposed onto the added-mass force due to the linearity of the governing Laplace equation. This decomposition of force into added-mass and circulatory components remains common in modern aerodynamic models, but its applicability to viscous separated flows remains unclear. The present work addresses this knowledge gap by presenting a generalized derivation of the added-mass and circulatory force decomposition which is valid for a body of arbitrary shape in an unbounded, incompressible fluid domain, in both two and three dimensions, undergoing arbitrary motions amid continuous distributions of vorticity. From the general expression, the classical added-mass force is rederived for well-known canonical cases and is seen to be additive to the circulatory force for any flow. The formulation is shown to be equivalent to existing theoretical work under the specific conditions and assumptions of previous studies. It is also validated using a numerical simulation of a pitching plate in a steady freestream flow, conducted by Wang and Eldredge [Theor. Comput. Fluid Dyn. 27, 577 (2013), 10.1007/s00162-012-0279-5]. In response to persistent confusion in the literature, a discussion of the most appropriate physical interpretation of added mass is included, informed by inspection of the derived equations. The added-mass force is seen to account for the dynamic effect of near-body vorticity and is not (as is commonly claimed) associated with the acceleration of near-body fluid which "must" somehow move with the body. Various other consequences of the derivation are discussed, including a concept which has been labeled the conservation of image-vorticity impulse.

  10. Chronic Abdominal Wall Pain.

    PubMed

    Koop, Herbert; Koprdova, Simona; Schürmann, Christine

    2016-01-29

    Chronic abdominal wall pain is a poorly recognized clinical problem despite being an important element in the differential diagnosis of abdominal pain. This review is based on pertinent articles that were retrieved by a selective search in PubMed and EMBASE employing the terms "abdominal wall pain" and "cutaneous nerve entrapment syndrome," as well as on the authors' clinical experience. In 2% to 3% of patients with chronic abdominal pain, the pain arises from the abdominal wall; in patients with previously diagnosed chronic abdominal pain who have no demonstrable pathological abnormality, this likelihood can rise as high as 30% . There have only been a small number of clinical trials of treatment for this condition. The diagnosis is made on clinical grounds, with the aid of Carnett's test. The characteristic clinical feature is strictly localized pain in the anterior abdominal wall, which is often mischaracterized as a "functional" complaint. In one study, injection of local anesthesia combined with steroids into the painful area was found to relieve pain for 4 weeks in 95% of patients. The injection of lidocaine alone brought about improvement in 83-91% of patients. Long-term pain relief ensued after a single lidocaine injection in 20-30% of patients, after repeated injections in 40-50% , and after combined lidocaine and steroid injections in up to 80% . Pain that persists despite these treatments can be treated with surgery (neurectomy). Chronic abdominal wall pain is easily diagnosed on physical examination and can often be rapidly treated. Any physician treating patients with abdominal pain should be aware of this condition. Further comparative treatment trials will be needed before a validated treatment algorithm can be established.

  11. Recent advances in computational methodology for simulation of mechanical circulatory assist devices

    PubMed Central

    Marsden, Alison L.; Bazilevs, Yuri; Long, Christopher C.; Behr, Marek

    2014-01-01

    Ventricular assist devices (VADs) provide mechanical circulatory support to offload the work of one or both ventricles during heart failure. They are used in the clinical setting as destination therapy, as bridge to transplant, or more recently as bridge to recovery to allow for myocardial remodeling. Recent developments in computational simulation allow for detailed assessment of VAD hemodynamics for device design and optimization for both children and adults. Here, we provide a focused review of the recent literature on finite element methods and optimization for VAD simulations. As VAD designs typically fall into two categories, pulsatile and continuous flow devices, we separately address computational challenges of both types of designs, and the interaction with the circulatory system with three representative case studies. In particular, we focus on recent advancements in finite element methodology that has increased the fidelity of VAD simulations. We outline key challenges, which extend to the incorporation of biological response such as thrombosis and hemolysis, as well as shape optimization methods and challenges in computational methodology. PMID:24449607

  12. [Prevention of circulatory system diseases in underground mining workers].

    PubMed

    Vlasova, E M; Alexeyev, M B; Shliapnikov, D M; Nosov, A E; Barannikov, V G

    2015-01-01

    The article covers results of preventive measures in workers engaged into underground mining. Those measures are aimed to prevent occupationally mediated health disorders resulting in circulatory diseases. The prophylaxis was proven effective on premorbid condition--that was demonstrated in reliable decrease of cause-effect relationship intensity for health disorders in workers subjected to prophylactic measures. Transitory disablement morbidity due to cicrulatory system diseases decreased. Situational modelling of risk changes for the studied group demonstrated changes of diseases risk under medical prophylactic measures. After the prophylaxis, the risk demonstrated 3.1 times decrease.

  13. Favorable Circulatory System Outcomes as Adjuvant Traditional Chinese Medicine (TCM) Treatment for Cerebrovascular Diseases in Taiwan

    PubMed Central

    Chiu, Hsienhsueh Elley; Hong, Yu-Chiang; Chang, Ku-Chou; Shih, Chun-Chuan; Hung, Jen-Wen; Liu, Chia-Wei; Tan, Teng-Yeow; Huang, Chih-Cheng

    2014-01-01

    Abstract Background This study searches the National Health Insurance Research Database (NHIRD) used in a previous project, aiming for reconstructing possible cerebrovascular disease-related groups (DRG),and estimating the costs between cerebrovascular disease and related diseases. Methods and Materials We conducted a nationwide retrospective cohort study in stroke inpatients, we examined the overall costs in 3 municipalities in Taiwan, by evaluating the possible costs of the expecting diagnosis related group (DRG) by using the international classification of diseases version-9 (ICD-9) system, and the overall analysis of the re-admission population that received traditional Chinese medicine (TCM) treatment and those who did not. Results The trend demonstrated that the non-participant costs were consistent with the ICD-9 categories (430 to 437) because similarities existed between years 2006 to 2007. Among the TCM patients, a wide variation and additional costs were found compared to non-TCM patients during these 2 years. The average re-admission duration was significantly shorter for TCM patients, especially those initially diagnosed with ICD 434 during the first admission. In addition, TCM patients demonstrated more severe general symptoms, which incurred high conventional treatment costs, and could result in re-admission for numerous reasons. However, in Disease 7 of ICD-9 category, representing the circulatory system was most prevalent in non-TCM inpatients, which was the leading cause of re-admission. Conclusion We concluded that favorable circulatory system outcomes were in adjuvant TCM treatment inpatients, there were less re-admission for circulatory system events and a two-third reduction of re-admission within ICD-9 code 430 to 437, compared to non-TCM ones. However, there were shorter re-admission duration other than circulatory system events by means of unfavorable baseline condition. PMID:24475108

  14. Pantoprazole: a new proton pump inhibitor.

    PubMed

    Jungnickel, P W

    2000-11-01

    This paper reviews the pharmacology, clinical efficacy, and tolerability of pantoprazole in comparison with those of other available proton pump inhibitors (PPIs). Relevant English-language research and review articles were identified by database searches of MEDLINE, International Pharmaceutical Abstracts, and UnCover, and by examining the reference lists of the articles so identified. In selecting data for inclusion, the author gave preference to full-length articles published in peer-reviewed journals. Like other PPIs, pantoprazole exerts its pharmacodynamic actions by binding to the proton pump (H+,K+ -adenosine triphosphatase) in the parietal cells, but, compared with other PPIs, its binding may be more specific for the proton pump. Pantoprazole is well absorbed when administered as an enteric-coated, delayed-release tablet, with an oral bioavailability of approximately 77%. It is hepatically metabolized via cytochrome P2C19 to hydroxypantoprazole, an inactive metabolite that subsequently undergoes sulfate conjugation. The elimination half-life ranges from 0.9 to 1.9 hours and is independent of dose. Pantoprazole has similar efficacy to other PPIs in the healing of gastric and duodenal ulcers, as well as erosive esophagitis, and as part of triple-drug regimens for the eradication of Helicobacter pylori from the gastric mucosa. It is well tolerated, with the most common adverse effects being headache, diarrhea, flatulence, and abdominal pain. In clinical studies, it has been shown to have no interactions with various other agents, including carbamazepine, cisapride, cyclosporine, digoxin, phenytoin, theophylline, and warfarin. Pantoprazole appears to be as effective as other PPIs. Its low potential for drug interactions may give it an advantage in patients taking other drugs.

  15. Towards a Fast Dynamic Model of the Human Circulatory System

    DTIC Science & Technology

    2011-10-06

    heart chambers, and the local time-varying pressure is not prescribed anywhere. The effects of muscle contraction and relaxation on the circulatory...0.5 < S < 2) area during skeletal muscle contraction . Contraction only applied on the venous end of the vascular tree (1.25 < S < 2). For the... contraction , occurring during time (tam < t < tbm), and ∆Am is the maximum contraction amplitude. A visualization of the muscle contraction model is shown in

  16. Patient-specific biomechanical model of hypoplastic left heart to predict post-operative cardio-circulatory behaviour.

    PubMed

    Cutrì, Elena; Meoli, Alessio; Dubini, Gabriele; Migliavacca, Francesco; Hsia, Tain-Yen; Pennati, Giancarlo

    2017-09-01

    Hypoplastic left heart syndrome is a complex congenital heart disease characterised by the underdevelopment of the left ventricle normally treated with a three-stage surgical repair. In this study, a multiscale closed-loop cardio-circulatory model is created to reproduce the pre-operative condition of a patient suffering from such pathology and virtual surgery is performed. Firstly, cardio-circulatory parameters are estimated using a fully closed-loop cardio-circulatory lumped parameter model. Secondly, a 3D standalone FEA model is build up to obtain active and passive ventricular characteristics and unloaded reference state. Lastly, the 3D model of the single ventricle is coupled to the lumped parameter model of the circulation obtaining a multiscale closed-loop pre-operative model. Lacking any information on the fibre orientation, two cases were simulated: (i) fibre distributed as in the physiological right ventricle and (ii) fibre as in the physiological left ventricle. Once the pre-operative condition is satisfactorily simulated for the two cases, virtual surgery is performed. The post-operative results in the two cases highlighted similar hemodynamic behaviour but different local mechanics. This finding suggests that the knowledge of the patient-specific fibre arrangement is important to correctly estimate the single ventricle's working condition and consequently can be valuable to support clinical decision. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  17. Cardiorespiratory interactions in neural circulatory control in humans.

    PubMed

    Shamsuzzaman, A S; Somers, V K

    2001-06-01

    The reflex mechanisms and interactions described in this overview provide some explanation for the range of neural circulatory responses evident during changes in breathing. The effects described represent the integrated responses to activation of several reflex mechanisms, including peripheral and central chemoreflexes, arterial baroreflexes, pulmonary stretch receptors, and ventricular mechanoreceptors. These interactions occur on a dynamic basis and the transfer characteristics of any single interaction are, in all likelihood, also highly dynamic. Nevertheless, it is only by attempting to understand individual reflexes and their modulating influences that a more thorough understanding of the responses to complex phenomena such as hyperventilation, apnea, and obstructive sleep apnea can be better understood.

  18. Evaluation of exercise-respiratory system modifications and preliminary respiratory-circulatory system integration scheme

    NASA Technical Reports Server (NTRS)

    Gallagher, R. R.

    1974-01-01

    The respiratory control system, functioning as an independent system, is presented with modifications of the exercise subroutine. These modifications illustrate an improved control of ventilation rates and arterial and compartmental gas tensions. A very elementary approach to describing the interactions of the respiratory and circulatory system is presented.

  19. A LabVIEW model incorporating an open-loop arterial impedance and a closed-loop circulatory system.

    PubMed

    Cole, R T; Lucas, C L; Cascio, W E; Johnson, T A

    2005-11-01

    While numerous computer models exist for the circulatory system, many are limited in scope, contain unwanted features or incorporate complex components specific to unique experimental situations. Our purpose was to develop a basic, yet multifaceted, computer model of the left heart and systemic circulation in LabVIEW having universal appeal without sacrificing crucial physiologic features. The program we developed employs Windkessel-type impedance models in several open-loop configurations and a closed-loop model coupling a lumped impedance and ventricular pressure source. The open-loop impedance models demonstrate afterload effects on arbitrary aortic pressure/flow inputs. The closed-loop model catalogs the major circulatory waveforms with changes in afterload, preload, and left heart properties. Our model provides an avenue for expanding the use of the ventricular equations through closed-loop coupling that includes a basic coronary circuit. Tested values used for the afterload components and the effects of afterload parameter changes on various waveforms are consistent with published data. We conclude that this model offers the ability to alter several circulatory factors and digitally catalog the most salient features of the pressure/flow waveforms employing a user-friendly platform. These features make the model a useful instructional tool for students as well as a simple experimental tool for cardiovascular research.

  20. Students' Visualization of Diagrams Representing the Human Circulatory System: The use of spatial isomorphism and representational conventions

    NASA Astrophysics Data System (ADS)

    Cheng, Maurice M. W.; Gilbert, John K.

    2015-01-01

    This study investigated students' interpretation of diagrams representing the human circulatory system. We conducted an interview study with three students aged 14-15 (Year 10) who were studying biology in a Hong Kong school. During the interviews, students were asked to interpret diagrams and relationships between diagrams that represented aspects of the circulatory system. All diagrams used in the interviews had been used by their teacher when teaching the topic. Students' interpretations were expressed by their verbal response and their drawing. Dual coding theory was used to interpret students' responses. There was evidence that one student relied on verbal recall as a strategy in interpreting diagrams. It was found that students might have relied unduly on similarities in spatial features, rather than on deeper meanings represented by conventions, of diagrams when they associated diagrams that represented different aspects of the circulatory system. A pattern of students' understanding of structure-behaviour-function relationship of the biological system was observed. This study suggests the importance of a consistent diagrammatic and verbal representation in communicating scientific ideas. Implications for teaching practice that facilitates learning with diagrams and address students' undue focus on spatial features of diagrams are discussed.

  1. Retrospective comparison of abdominal ultrasonography and radiography in the investigation of feline abdominal disease

    PubMed Central

    Won, Wylen Wade; Sharma, Ajay; Wu, Wenbo

    2015-01-01

    Abdominal radiography and ultrasonography are commonly used as part of the initial diagnostic plan for cats with nonspecific signs of abdominal disease. This retrospective study compared the clinical usefulness of abdominal radiography and ultrasonography in 105 feline patients with signs of abdominal disease. The final diagnosis was determined more commonly with ultrasonography (59%) compared to radiography (25.7%). Ultrasonography was also able to provide additional clinically relevant information in 76% of cases, and changed or refined the diagnosis in 47% of cases. Based on these findings, ultrasonography may be sufficient as an initial diagnostic test for the investigation of feline abdominal disease. PMID:26483582

  2. The Tribolium homeotic gene Abdominal is homologous to abdominal-A of the Drosophila bithorax complex

    NASA Technical Reports Server (NTRS)

    Stuart, J. J.; Brown, S. J.; Beeman, R. W.; Denell, R. E.; Spooner, B. S. (Principal Investigator)

    1993-01-01

    The Abdominal gene is a member of the single homeotic complex of the beetle, Tribolium castaneum. An integrated developmental genetic and molecular analysis shows that Abdominal is homologous to the abdominal-A gene of the bithorax complex of Drosophila. abdominal-A mutant embryos display strong homeotic transformations of the anterior abdomen (parasegments 7-9) to PS6, whereas developmental commitments in the posterior abdomen depend primarily on Abdominal-B. In beetle embryos lacking Abdominal function, parasegments throughout the abdomen are transformed to PS6. This observation demonstrates the general functional significance of parasegmental expression among insects and shows that the control of determinative decisions in the posterior abdomen by homeotic selector genes has undergone considerable evolutionary modification.

  3. The Tribolium homeotic gene Abdominal is homologous to abdominal-A of the Drosophila bithorax complex.

    PubMed

    Stuart, J J; Brown, S J; Beeman, R W; Denell, R E

    1993-01-01

    The Abdominal gene is a member of the single homeotic complex of the beetle, Tribolium castaneum. An integrated developmental genetic and molecular analysis shows that Abdominal is homologous to the abdominal-A gene of the bithorax complex of Drosophila. abdominal-A mutant embryos display strong homeotic transformations of the anterior abdomen (parasegments 7-9) to PS6, whereas developmental commitments in the posterior abdomen depend primarily on Abdominal-B. In beetle embryos lacking Abdominal function, parasegments throughout the abdomen are transformed to PS6. This observation demonstrates the general functional significance of parasegmental expression among insects and shows that the control of determinative decisions in the posterior abdomen by homeotic selector genes has undergone considerable evolutionary modification.

  4. [Differential diagnosis of abdominal pain].

    PubMed

    Frei, Pascal

    2015-09-02

    Despite the frequency of functional abdominal pain, potentially dangerous causes of abdominal pain need to be excluded. Medical history and clinical examination must focus on red flags and signs for imflammatory or malignant diseases. See the patient twice in the case of severe and acute abdominal pain if lab parameters or radiological examinations are normal. Avoid repeated and useless X-ray exposure whenever possible. In the case of subacute or chronic abdominal pain, lab tests such as fecal calprotectin, helicobacter stool antigen and serological tests for celiac disease are very useful. Elderly patients may show atypical or missing clinical signs. Take care of red herrings and be skeptical whether your initial diagnosis is really correct. Abdominal pain can frequently be an abdominal wall pain.

  5. Nitroglycerin reverts clinical manifestations of poor peripheral perfusion in patients with circulatory shock

    PubMed Central

    2014-01-01

    Introduction Recent clinical studies have shown a relationship between abnormalities in peripheral perfusion and unfavorable outcome in patients with circulatory shock. Nitroglycerin is effective in restoring alterations in microcirculatory blood flow. The aim of this study was to investigate whether nitroglycerin could correct the parameters of abnormal peripheral circulation in resuscitated circulatory shock patients. Methods This interventional study recruited patients who had circulatory shock and who persisted with abnormal peripheral perfusion despite normalization of global hemodynamic parameters. Nitroglycerin started at 2 mg/hour and doubled stepwise (4, 8, and 16 mg/hour) each 15 minutes until an improvement in peripheral perfusion was observed. Peripheral circulation parameters included capillary refill time (CRT), skin-temperature gradient (Tskin-diff), perfusion index (PI), and tissue oxygen saturation (StO2) during a reactive hyperemia test (RincStO2). Measurements were performed before, at the maximum dose, and after cessation of nitroglycerin infusion. Data were analyzed by using linear model for repeated measurements and are presented as mean (standard error). Results Of the 15 patients included, four patients (27%) responded with an initial nitroglycerin dose of 2 mg/hour. In all patients, nitroglycerin infusion resulted in significant changes in CRT, Tskin-diff, and PI toward normal at the maximum dose of nitroglycerin: from 9.4 (0.6) seconds to 4.8 (0.3) seconds (P <0.05), from 3.3°C (0.7°C) to 0.7°C (0.6°C) (P <0.05), and from [log] -0.5% (0.2%) to 0.7% (0.1%) (P <0.05), respectively. Similar changes in StO2 and RincStO2 were observed: from 75% (3.4%) to 84% (2.7%) (P <0.05) and 1.9%/second (0.08%/second) to 2.8%/second (0.05%/second) (P <0.05), respectively. The magnitude of changes in StO2 was more pronounced for StO2 of less than 75%: 11% versus 4%, respectively (P <0.05). Conclusions Dose-dependent infusion of nitroglycerin reverted

  6. Comparison of outcomes of kidney transplantation from donation after brain death, donation after circulatory death, and donation after brain death followed by circulatory death donors.

    PubMed

    Chen, Guodong; Wang, Chang; Ko, Dicken Shiu-Chung; Qiu, Jiang; Yuan, Xiaopeng; Han, Ming; Wang, Changxi; He, Xiaoshun; Chen, Lizhong

    2017-11-01

    There are three categories of deceased donors of kidney transplantation in China, donation after brain death (DBD), donation after circulatory death (DCD), and donation after brain death followed by circulatory death (DBCD) donors. The aim of this study was to compare the outcomes of kidney transplantation from these three categories of deceased donors. We retrospectively reviewed 469 recipients who received deceased kidney transplantation in our hospital from February 2007 to June 2015. The recipients were divided into three groups according to the source of their donor kidneys: DBD, DCD, or DBCD. The primary endpoints were delayed graft function (DGF), graft loss, and patient death. The warm ischemia time was much longer in DCD group compared to DBCD group (18.4 minutes vs 12.9 minutes, P < .001). DGF rate was higher in DCD group than in DBD and DBCD groups (22.5% vs 10.2% and 13.8%, respectively, P = .021). Urinary leakage was much higher in DCD group (P = .049). Kaplan-Meier analysis showed that 1-, 2-, and 3-year patient survivals were all comparable among the three groups. DBCD kidney transplantation has lower incidences of DGF and urinary leakage than DCD kidney transplant. However, the overall patient and graft survival were comparable among DBD, DCD, and DBCD kidney transplantation. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. New Insight in Loss of Gut Barrier during Major Non-Abdominal Surgery

    PubMed Central

    Derikx, Joep P. M.; van Waardenburg, Dick A.; Thuijls, Geertje; Willigers, Henriëtte M.; Koenraads, Marianne; van Bijnen, Annemarie A.; Heineman, Erik; Poeze, Martijn; Ambergen, Ton; van Ooij, André; van Rhijn, Lodewijk W.; Buurman, Wim A.

    2008-01-01

    Background Gut barrier loss has been implicated as a critical event in the occurrence of postoperative complications. We aimed to study the development of gut barrier loss in patients undergoing major non-abdominal surgery. Methodology/Principal Findings Twenty consecutive children undergoing spinal fusion surgery were included. This kind of surgery is characterized by long operation time, significant blood loss, prolonged systemic hypotension, without directly leading to compromise of the intestines by intestinal manipulation or use of extracorporeal circulation. Blood was collected preoperatively, every two hours during surgery and 2, 4, 15 and 24 hours postoperatively. Gut mucosal barrier was assessed by plasma markers for enterocyte damage (I-FABP, I-BABP) and urinary presence of tight junction protein claudin-3. Intestinal mucosal perfusion was measured by gastric tonometry (PrCO2, Pr-aCO2-gap). Plasma concentration of I-FABP, I-BABP and urinary expression of claudin-3 increased rapidly and significantly after the onset of surgery in most children. Postoperatively, all markers decreased promptly towards baseline values together with normalisation of MAP. Plasma levels of I-FABP, I-BABP were significantly negatively correlated with MAP at ½ hour before blood sampling (−0.726 (p<0.001), −0.483 (P<0.001), respectively). Furthermore, circulating I-FABP correlated with gastric mucosal PrCO2, Pr-aCO2-gap measured at the same time points (0.553 (p = 0.040), 0.585 (p = 0.028), respectively). Conclusions/Significance This study shows the development of gut barrier loss in children undergoing major non-abdominal surgery, which is related to preceding hypotension and mesenterial hypoperfusion. These data shed new light on the potential role of peroperative circulatory perturbation and intestinal barrier loss. PMID:19088854

  8. The role of extracorporeal membrane oxygenation circulatory support in the 'crash and burn' patient: from implantation to weaning.

    PubMed

    Ghodsizad, Ali; Koerner, Michael M; Brehm, Christoph E; El-Banayosy, Aly

    2014-05-01

    In advanced cardiogenic shock, early mechanical circulatory support may prevent multiorgan failure and death. In this article, we are describing our experience with extracorporeal membrane oxygenation (ECMO) application. Venoarterial ECMO has been used successfully as a therapeutic option for patients with advanced cardiogenic shock and cardiac arrest. In this review, based on the daily routine of the Hershey group using ECMO for therapy of advanced cardiogenic shock, the application of ECMO is described. The aim is to share our hands-on experience during emergent implantation and to contribute to the knowledge within the field of mechanical circulatory support.

  9. Chronic abdominal wall pain and ultrasound-guided abdominal cutaneous nerve infiltration: a case series.

    PubMed

    Kanakarajan, Saravanakumar; High, Kristina; Nagaraja, Ravi

    2011-03-01

    Chronic abdominal wall pain occurs in about 10-30% of patients presenting with chronic abdominal pain. Entrapment of abdominal cutaneous nerves at the lateral border of the rectus abdominis muscle has been attributed as a cause of abdominal wall pain. We report our experience of treating such patients using ultrasound-guided abdominal cutaneous nerve infiltration. We conducted a retrospective audit of abdominal cutaneous nerve infiltration performed in the period between September 2008 to August 2009 in our center. All patients had received local anesthetic and steroid injection under ultrasound guidance. The response to the infiltration was evaluated in the post-procedure telephone review as well as in the follow-up clinic. Brief pain inventory (BPI) and numerical rating scale pain scores were collated from two points: the initial outpatient clinic and the follow up clinic up to 5 months following the injection. Nine patients had abdominal cutaneous nerve injections under ultrasound guidance in the period under review. Six patients reported 50% pain relief or more (responders) while three patients did not. Pain and BPI scores showed a decreasing trend in responders. The median duration of follow-up was 12 weeks. Ultrasound can reliably be used for infiltration of the abdominal cutaneous nerves. This will improve the safety as well as diagnostic utility of the procedure. Wiley Periodicals, Inc.

  10. Acoustic Pump

    NASA Technical Reports Server (NTRS)

    Heyman, Joseph S.

    1993-01-01

    Pump uses acoustic-radiation forces. Momentum transferred from sound waves to sound-propagating material in way resulting in net pumping action on material. Acoustic pump is solid-state pump. Requires no moving parts, entirely miniaturized, and does not invade pumped environment. Silent, with no conventional vibration. Used as pump for liquid, suspension, gas, or any other medium interacting with radiation pressure. Also used where solid-state pump needed for reliability and controllability. In microgravity environment, device offers unusual control for low flow rates. For medical or other applications in which contamination cannot be allowed, offers noninvasive pumping force.

  11. PUMP CONSTRUCTION

    DOEpatents

    Strickland, G.; Horn, F.L.; White, H.T.

    1960-09-27

    A pump which utilizes the fluid being pumped through it as its lubricating fluid is described. This is achieved by means of an improved bearing construction in a pump of the enclosed or canned rotor type. At the outlet end of the pump, adjacent to an impeller mechanism, there is a bypass which conveys some of the pumped fluid to a chamber at the inlet end of the pump. After this chamber becomes full, the pumped fluid passes through fixed orifices in the top of the chamber and exerts a thrust on the inlet end of the pump rotor. Lubrication of the rotor shaft is accomplished by passing the pumped fluid through a bypass at the outlet end of the rotor shaft. This bypass conveys Pumped fluid to a cooling means and then to grooves on the surface of the rotor shait, thus lubricating the shaft.

  12. Abdominal elephantiasis: a case report.

    PubMed

    Hanna, Dominique; Cloutier, Richard; Lapointe, Roch; Desgagné, Antoine

    2004-01-01

    Elephantiasis is a well-known condition in dermatology usually affecting the legs and external genitalia. It is characterized by chronic inflammation and obstruction of the lymphatic channels and by hypertrophy of the skin and subcutaneous tissues. The etiology is either idiopathic or caused by a variety of conditions such as chronic filarial disease, leprosy, leishmaniasis, and chronic recurrent cellulites. Elephantiasis of the abdominal wall is very rare. A complete review of the English and French literature showed only two cases reported in 1966 and 1973, respectively. We report a third case of abdominal elephantiasis and we briefly review this entity. We present the case of a 51-year-old woman who had progressively developed an enormous pediculated abdominal mass hanging down her knees. The skin was thickened, hyperpigmented, and fissured. She had a history of multiple abdominal cellulites. She underwent an abdominal lipectomy. Histopathology of the specimen confirmed the diagnosis of abdominal elephantiasis. Abdominal elephantiasis is a rare disease that represents end-stage failure of lymph drainage. Lipectomy should be considered in the management of this condition.

  13. [Medicinal plants useful in the cure of circulatory problems in legs].

    PubMed

    Alonso, Maria José

    2005-03-01

    Once the fundamentals of phyto-therapy in its western use are understood, this article presents concrete a application of medicinal plants: circulatory problems in legs, a problem which affects a growing sector of the population. According to epidemiological studies, close to 80% of adults suffer problems such as tired legs, swellings, edemas, cramps, or varicose veins during their lifetimes; these appear due to an insufficiency when veins can not conveniently transport blood to the heart.

  14. In vitro comparison of intra-abdominal hypertension development after different temporary abdominal closure techniques.

    PubMed

    Benninger, Emanuel; Labler, Ludwig; Seifert, Burkhardt; Trentz, Otmar; Menger, Michael D; Meier, Christoph

    2008-01-01

    To compare volume reserve capacity (VRC) and development of intra-abdominal hypertension after different in vitro temporary abdominal closure (TAC) techniques. A model of the abdomen was designed. The abdominal wall was simulated with polychloroprene, a synthetic rubber compound. A lentil-shaped defect of 150 cm(2) was cut into the anterior aspect of the abdominal wall. TAC of this defect was performed by a zipper system (ZS), a bag silo closure (BSC), or a vacuum assisted closure (VAC) with subatmospheric pressures ranging from 0- to 200 mmHg. The model with intact abdominal wall served as reference. The model was filled with water to baseline level. The intra-abdominal pressure was increased in 2 mmHg steps from baseline level (6 mmHg) to 40 mmHg by adding volume to the system according to a standardized protocol. VRC with corresponding intra-abdominal pressure were analyzed and compared for the different TAC techniques. VRC was the highest after BSC at all pressure levels studied (P < 0.05). VAC and ZS resulted in significantly lower VRC compared with BSC and reference (P < 0.05). The magnitude of negative pressure on the VAC did not significantly influence the VRC. In the present in vitro model, BSC demonstrated the highest VRC of all evaluated TAC techniques. Different levels of subatmospheric pressures applied to the VAC did not affect VRC. The results for ZS and VAC indicate that these TAC techniques may increase the risk for recurrent intra-abdominal hypertension and should therefore not be used in high-risk patients during the initial phase after abdominal decompression.

  15. Development of a disposable magnetically levitated centrifugal blood pump (MedTech Dispo) intended for bridge-to-bridge applications--two-week in vivo evaluation.

    PubMed

    Nagaoka, Eiki; Someya, Takeshi; Kitao, Takashi; Kimura, Taro; Ushiyama, Tomohiro; Hijikata, Wataru; Shinshi, Tadahiko; Arai, Hirokuni; Takatani, Setsuo

    2010-09-01

    Last year, we reported in vitro pump performance, low hemolytic characteristics, and initial in vivo evaluation of a disposable, magnetically levitated centrifugal blood pump, MedTech Dispo. As the first phase of the two-stage in vivo studies, in this study we have carried out a 2-week in vivo evaluation in calves. Male Holstein calves with body weight of 62.4–92.2 kg were used. Under general anesthesia, a left heart bypass with a MedTech Dispo pump was instituted between the left atrium and the descending aorta via left thoracotomy. Blood-contacting surface of the pump was coated with a 2-methacryloyloxyethyl phosphorylcholine polymer. Post-operatively, with activated clotting time controlled at 180–220 s using heparin and bypass flow rate maintained at 50 mL/kg/min, plasma-free hemoglobin (Hb), coagulation, and major organ functions were analyzed for evaluation of biocompatibility. The animals were electively sacrificed at the completion of the 2-week study to evaluate presence of thrombus inside the pump,together with an examination of major organs. To date, we have done 13 MedTech Dispo implantations, of which three went successfully for a 2-week duration. In these three cases, the pump produced a fairly constant flow of 50 mL/Kg/min. Neurological disorders and any symptoms of thromboembolism were not seen. Levels of plasma-free Hb were maintained very low. Major organ functions remained within normal ranges. Autopsy results revealed no thrombus formation inside the pump. In the last six cases, calves suffered from severe pneumonia and they were excluded from the analysis. The MedTech Dispo pump demonstrated sufficient pump performance and biocompatibility to meet requirements for 1-week circulatory support. The second phase (2-month in vivo study) is under way to prove the safety and efficacy of MedTech Dispo for 1-month applications. © 2010, Copyright the Authors. Artificial Organs © 2010, International Center for Artificial Organs and Transplantation

  16. Abdominal hernias: Radiological features

    PubMed Central

    Lassandro, Francesco; Iasiello, Francesca; Pizza, Nunzia Luisa; Valente, Tullio; Stefano, Maria Luisa Mangoni di Santo; Grassi, Roberto; Muto, Roberto

    2011-01-01

    Abdominal wall hernias are common diseases of the abdomen with a global incidence approximately 4%-5%. They are distinguished in external, diaphragmatic and internal hernias on the basis of their localisation. Groin hernias are the most common with a prevalence of 75%, followed by femoral (15%) and umbilical (8%). There is a higher prevalence in males (M:F, 8:1). Diagnosis is usually made on physical examination. However, clinical diagnosis may be difficult, especially in patients with obesity, pain or abdominal wall scarring. In these cases, abdominal imaging may be the first clue to the correct diagnosis and to confirm suspected complications. Different imaging modalities are used: conventional radiographs or barium studies, ultrasonography and Computed Tomography. Imaging modalities can aid in the differential diagnosis of palpable abdominal wall masses and can help to define hernial contents such as fatty tissue, bowel, other organs or fluid. This work focuses on the main radiological findings of abdominal herniations. PMID:21860678

  17. LMFBR with booster pump in pumping loop

    DOEpatents

    Rubinstein, H.J.

    1975-10-14

    A loop coolant circulation system is described for a liquid metal fast breeder reactor (LMFBR) utilizing a low head, high specific speed booster pump in the hot leg of the coolant loop with the main pump located in the cold leg of the loop, thereby providing the advantages of operating the main pump in the hot leg with the reliability of cold leg pump operation.

  18. Abdominal binders may reduce pain and improve physical function after major abdominal surgery - a systematic review.

    PubMed

    Rothman, Josephine Philip; Gunnarsson, Ulf; Bisgaard, Thue

    2014-11-01

    Evidence for the effect of post-operative abdominal binders on post-operative pain, seroma formation, physical function, pulmonary function and increased intra-abdominal pressure among patients after surgery remains largely un-investigated. A systematic review was conducted. The PubMed, EMBASE and Cochrane databases were searched for studies on the use of abdominal binders after abdominal surgery or abdominoplasty. All types of clinical studies were included. Two independent assessors evaluated the scientific quality of the studies. The primary outcomes were pain, seroma formation and physical function. A total of 50 publications were identified; 42 publications were excluded leaving eight publications counting a total of 578 patients for analysis. Generally, the scientific quality of the studies was poor. Use of abdominal binder revealed a non-significant tendency to reduce seroma formation after laparoscopic ventral herniotomy and a non-significant reduction in pain. Physical function was improved, whereas evidence supports a beneficial effect on psychological distress after open abdominal surgery. Evidence also supports that intra-abdominal pressure increases with the use of abdominal binders. Reduction of pulmonary function during use of abdominal binders has not been revealed. Abdominal binders reduce post-operative psychological distress, but their effect on post-operative pain after laparotomy and seroma formation after ventral hernia repair remains unclear. Due to the sparse evidence and poor quality of the literature, solid conclusions may be difficult to make, and procedure-specific, high-quality randomised clinical trials are warranted.

  19. Estimation of Filling and Afterload Conditions by Pump Intrinsic Parameters in a Pulsatile Total Artificial Heart.

    PubMed

    Cuenca-Navalon, Elena; Laumen, Marco; Finocchiaro, Thomas; Steinseifer, Ulrich

    2016-07-01

    A physiological control algorithm is being developed to ensure an optimal physiological interaction between the ReinHeart total artificial heart (TAH) and the circulatory system. A key factor for that is the long-term, accurate determination of the hemodynamic state of the cardiovascular system. This study presents a method to determine estimation models for predicting hemodynamic parameters (pump chamber filling and afterload) from both left and right cardiovascular circulations. The estimation models are based on linear regression models that correlate filling and afterload values with pump intrinsic parameters derived from measured values of motor current and piston position. Predictions for filling lie in average within 5% from actual values, predictions for systemic afterload (AoPmean , AoPsys ) and mean pulmonary afterload (PAPmean ) lie in average within 9% from actual values. Predictions for systolic pulmonary afterload (PAPsys ) present an average deviation of 14%. The estimation models show satisfactory prediction and confidence intervals and are thus suitable to estimate hemodynamic parameters. This method and derived estimation models are a valuable alternative to implanted sensors and are an essential step for the development of a physiological control algorithm for a fully implantable TAH. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  20. Abdominal Sepsis.

    PubMed

    De Waele, Jan J

    2016-08-01

    Abdominal infections are an important challenge for the intensive care physician. In an era of increasing antimicrobial resistance, selecting the appropriate regimen is important and, with new drugs coming to the market, correct use is important more than ever before and abdominal infections are an excellent target for antimicrobial stewardship programs. Biomarkers may be helpful, but their exact role in managing abdominal infections remains incompletely understood. Source control also remains an ongoing conundrum, and evidence is increasing that its importance supersedes the impact of antibiotic therapy. New strategies such as open abdomen management may offer added benefit in severely ill patients, but more data are needed to identify its exact role. The role of fungi and the need for antifungal coverage, on the other hand, have been investigated extensively in recent years, but at this point, it remains unclear who requires empirical as well as directed therapy.

  1. The Progress in the Novel Pediatric Rotary Blood Pump Sputnik Development.

    PubMed

    Telyshev, Dmitry; Denisov, Maxim; Pugovkin, Alexander; Selishchev, Sergey; Nesterenko, Igor

    2018-04-01

    stress distribution was calculated along the pump volume. The volume in which shear stress exceed 150 Pa is less than 0.38% of the total pump volume at flow rates of 1, 3, and 5 L/min. In this study, a mock circulatory system (MCS) allowing simulation of physiological cardiovascular characteristics was used to investigate the interaction of the Sputnik PRBP with the cardiovascular system. MCS allows reproducing the Frank-Starling autoregulation mechanism of the heart. PRBP behavior was tested in the speed range of 6 000 to 15 000 rpm. Decreased contractility can be expressed in a stroke volume decrease approximately from 18 to 4 mL and ventricle systolic pressure decrease approximately from 92 to 20 mm Hg. The left ventricle becomes fully supported at a pump speed of 10 000 rpm. At a pump speed of 14 000 rpm, the left ventricle goes into a suction state in which fluid almost does not accumulate in the ventricle and only passes through it to the pump. The proposed PRBP showed potential for improved clinical outcomes in pediatric patients with a body surface area greater than 0.6 m 2 and weight greater than 12 kg. © 2018 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  2. Abdominal Aortic Dissections

    PubMed Central

    Borioni, Raoul; Garofalo, Mariano; De Paulis, Ruggero; Nardi, Paolo; Scaffa, Raffaele; Chiariello, Luigi

    2005-01-01

    Isolated abdominal aortic dissections are rare events. Their anatomic and clinical features are different from those of atherosclerotic aneurysms. We report 4 cases of isolated abdominal aortic dissection that were successfully treated with surgical or endovascular intervention. The anatomic and clinical features and a review of the literature are also presented. PMID:15902826

  3. Da Vinci-assisted abdominal cerclage.

    PubMed

    Barmat, Larry; Glaser, Gretchen; Davis, George; Craparo, Frank

    2007-11-01

    To report the first placement of an abdominal cervicoisthmic cerclage using the da Vinci robot. Case report. Tertiary-care hospital. A 39-year-old female with a history of cervical insufficiency who required a cerclage and was not a candidate for transvaginal cerclage placement. Abdominal cervicoisthmic cerclage placement using the da Vinci robot. Ability to safely and successfully place an abdominal cerclage using the da Vinci robot. Abdominal cerclage was successfully placed using the da Vinci robot. The patient had minimal blood loss and was discharged to home on the same day as surgery. Da Vinci robot-assisted abdominal cerclage placement is an innovative application of robotic surgery and may alter the standard of care for women who require this surgery.

  4. Automated anatomical labeling method for abdominal arteries extracted from 3D abdominal CT images

    NASA Astrophysics Data System (ADS)

    Oda, Masahiro; Hoang, Bui Huy; Kitasaka, Takayuki; Misawa, Kazunari; Fujiwara, Michitaka; Mori, Kensaku

    2012-02-01

    This paper presents an automated anatomical labeling method of abdominal arteries. In abdominal surgery, understanding of blood vessel structure concerning with a target organ is very important. Branching pattern of blood vessels differs among individuals. It is required to develop a system that can assist understanding of a blood vessel structure and anatomical names of blood vessels of a patient. Previous anatomical labbeling methods for abdominal arteries deal with either of the upper or lower abdominal arteries. In this paper, we present an automated anatomical labeling method of both of the upper and lower abdominal arteries extracted from CT images. We obtain a tree structure of artery regions and calculate feature values for each branch. These feature values include the diameter, curvature, direction, and running vectors of a branch. Target arteries of this method are grouped based on branching conditions. The following processes are separately applied for each group. We compute candidate artery names by using classifiers that are trained to output artery names. A correction process of the candidate anatomical names based on the rule of majority is applied to determine final names. We applied the proposed method to 23 cases of 3D abdominal CT images. Experimental results showed that the proposed method is able to perform nomenclature of entire major abdominal arteries. The recall and the precision rates of labeling are 79.01% and 80.41%, respectively.

  5. Functional abdominal pain.

    PubMed

    Grover, Madhusudan; Drossman, Douglas A

    2010-10-01

    Functional abdominal pain syndrome (FAPS) is a relatively less common functional gastrointestinal (GI) disorder defined by the presence of constant or frequently recurring abdominal pain that is not associated with eating, change in bowel habits, or menstrual periods (Drossman Gastroenterology 130:1377-1390, 2006), which points to a more centrally targeted (spinal and supraspinal) basis for the symptoms. However, FAPS is frequently confused with irritable bowel syndrome and other functional GI disorders in which abdominal pain is associated with eating and bowel movements. FAPS also differs from chronic abdominal pain associated with entities such as chronic pancreatitis or chronic inflammatory bowel disease, in which the pain is associated with peripherally acting factors (eg, gut inflammation or injury). Given the central contribution to the pain experience, concomitant psychosocial disturbances are common and strongly influence the clinical expression of FAPS, which also by definition is associated with loss of daily functioning. These factors make it critical to use a biopsychosocial construct to understand and manage FAPS, because gut-directed treatments are usually not successful in managing this condition.

  6. [Abdominal traumatic evisceration: reconstruction abdominal wall with biologic mesh and negative pressure therapy].

    PubMed

    Jiménez Gómez, M; Betancor Rivera, N; Lima Sánchez, J; Hernández Hernández, J R

    2016-04-10

    Abdominal traumatic evisceration as a result of high energy trauma is uncommon. Once repaired the possible internal damage, an abdominal wall defect of high complexity may exist, whose reconstruction represents a surgical challenge. Politraumatized male with important abdominal muculocutaneous avulsion and evisceration. After initial repair, the patient developed a big eventration in which we use a porcine dermis-derived mesh (Permacol TM ), a safe and effective alternative in abdominal wall repair, thanks to its seamless integration with other tissues, even when exposed. Negative pressure therapy has been used for the management of wound complications after surgical implantation of PermacolTM mesh. We describe our experience with the use of PermacolTM mesh and negative pressure therapy to aid the wound closure after skin necrosis and exposed mesh.

  7. In vitro microfluidic circulatory system for circulating cancer cells

    PubMed Central

    wan, jiandi; Fan, Rong; Emery, Travis; Zhang, Yongguo; Xia, Yuxuan; Sun, Jun; Wan, Jiandi

    2016-01-01

    Circulating tumor cells (CTCs) experience hemodynamic shear stress in circulation and play critical roles in cancer metastasis. The effect of shear on CTCs, however, remains less studied. Here, we described a protocol to circulate HCT116 human colon cancer cells in a microfluidic circulatory system mimicking physiologically relevant circulating conditions. This protocol represents a useful scaffold to mimic the transportation of CTCs in circulation and thus provides an effective means to study the effect of shear on CTCs. We anticipate that future studies using the developed system will help us to further investigate the regulatory roles of shear in molecular responses of CTCs. PMID:28690779

  8. A Numerical Modeling of A Vascular Implantable Cardiac Endovascular Assistant (AVICENA)

    NASA Astrophysics Data System (ADS)

    Rahmani, Shahrokh; Tehrani, Pedram; Karimi, Alireza; Alizadeh, Mansour; Navidbakhsh, Mahdi

    2015-10-01

    Cardiovascular diseases have been recently shown to have a pivotal role in human death and endangers lives of many people around the world. One of the most common cardiovascular diseases is poor performance of left ventricle. In this case, the ventricle cannot pump the blood into the aorta and circulatory system with a suitable power which is required for normal circulatory system. AVICENA is a new cardiac assist device which is implanted into the aorta to help the ventricle to pump the blood into circulatory system with more power and to make a better perfusion of the coronary arteries as well. To reach a desire value of rotational speed of the pump, a control circuit is designed for counterpulsation of AVICENA based on the outcomes from previous studies. This control circuit uses a PID controller. The present study aims to simulate the blood flow through the balloon part of AVICENA in a heart cycle with focusing on the calculation of its pump rotational speed by controlling the electrical current of the pump. Results revealed that the desired rotational speed of the pump can be achieved according to the previous aorta pressure cycle by electrical current control which is higher during balloon inflation in comparison with balloon deflation. These findings may have implications not only for understanding the performance of AVICENA but also to help cardiac mechanics experts to improve the shortcoming of this newborn device.

  9. Generation of Recombinant Human AChE OP-Scavengers with Extended Circulatory Longevity

    DTIC Science & Technology

    2006-11-01

    PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Avigdor Shafferman Ph.D. 5d. PROJECT NUMBER 5e. TASK NUMBER E-Mail: avigdor...glycans of rHuAChE, and in particular the distal termini of these glycan 8 projections , constitute a major factor in determining the circulatory...experiments funded by sources other than the USAMRMC contract, since they may have a major impact on the present project . Section III focuses on the

  10. Intra-abdominal pressure during swimming.

    PubMed

    Moriyama, S; Ogita, F; Huang, Z; Kurobe, K; Nagira, A; Tanaka, T; Takahashi, H; Hirano, Y

    2014-02-01

    The present study aimed to determine the intra-abdominal pressure during front crawl swimming at different velocities in competitive swimmers and to clarify the relationships between stroke indices and changes in intra-abdominal pressure. The subjects were 7 highly trained competitive collegiate male swimmers. Intra-abdominal pressure was measured during front crawl swimming at 1.0, 1.2 and 1.4 m · s(-1) and during the Valsalva maneuver. Intra-abdominal pressure was taken as the difference between minimum and maximum values, and the mean of 6 stable front crawl stroke cycles was used. Stroke rate and stroke length were also measured as stroke indices. There were significant differences in stroke rate among all velocities (P < 0.05). However, there was no significant difference in stroke length by velocity. Significant within-subject correlations between intra-abdominal pressure and stroke rate or stroke length (P < 0.01) were observed, although there were no significant correlations between intra-abdominal pressure and stroke indices when controlling for swimming velocity. These findings do not appear to support the effectiveness of trunk training performed by competitive swimmers aimed at increasing intra-abdominal pressure. © Georg Thieme Verlag KG Stuttgart · New York.

  11. Continuously pumping and reactivating gas pump

    DOEpatents

    Batzer, T.H.; Call, W.R.

    Apparatus for continuous pumping using cycling cryopumping panels. A plurality of liquid helium cooled panels are surrounded by movable nitrogen cooled panels that alternatively expose or shield the helium cooled panels from the space being pumped. Gases condense on exposed helium cooled panels until the nitrogen cooled panels are positioned to isolate the helium cooled panels. The helium cooled panels are incrementally warmed, causing captured gases to accumulate at the base of the panels, where an independant pump removes the gases. After the helium cooled panels are substantially cleaned of condensate, the nitrogen cooled panels are positioned to expose the helium cooled panels to the space being pumped.

  12. Continuously pumping and reactivating gas pump

    DOEpatents

    Batzer, Thomas H.; Call, Wayne R.

    1984-01-01

    Apparatus for continuous pumping using cycling cyropumping panels. A plurality of liquid helium cooled panels are surrounded by movable nitrogen cooled panels the alternatively expose or shield the helium cooled panels from the space being pumped. Gases condense on exposed helium cooled panels until the nitrogen cooled panels are positioned to isolate the helium cooled panels. The helium cooled panels are incrementally warmed, causing captured gases to accumulate at the base of the panels, where an independent pump removes the gases. After the helium cooled panels are substantially cleaned of condensate, the nitrogen cooled panels are positioned to expose the helium cooled panels to the space being pumped.

  13. Abdominal Aortic Aneurysm (AAA)

    MedlinePlus

    ... plaque buildup causes the walls of the abdominal aorta to become weak and bulge outward like a ... treated? What is an abdominal aortic aneurysm? The aorta, the largest artery in the body, is a ...

  14. Abdominal Wall Endometriosis Mimicking Metastases.

    PubMed

    Nambiar, Rakul; Anoop, T M; Mony, Rari P

    2018-06-01

    Abdominal wall lesions can be broadly divided into nontumorous and tumorous conditions. Nontumorous lesions include congenital lesion, abdominal wall hernia, inflammation and infection, vascular lesions, and miscellaneous conditions like hematoma. Tumorous lesions include benign and malignant neoplasms. Here, we report an unusual case of abdominal wall endometriosis mimicking metastases in a patient with breast carcinoma.

  15. Effect of Panpal pretreatment and antidotal treatment (HI-6 plus benactyzine) on respiratory and circulatory function in soman-poisoned rats.

    PubMed

    Kassa, J; Fusek, J

    1997-10-01

    1 The effect of pharmacological pretreatment (pyridostigmine, benactyzine and trihexyphenidyle), designated Panpal, and antidotal treatment (the oxime HI-6 plus benactyzine) in soman poisoning was investigated in a rat model with on-line monitoring of respiratory and circulatory parameters. 2 Soman poisoning caused a high decrease in respiratory rate as well as minute respiratory volume and an increase in mean arterial pressure from 30-120 min following soman challenge. Soman at sublethal dose also significantly inhibited acetylcholinesterase activity in diaphragm and various brain parts. 3 Panpal pretreatment as well as antidotal treatment were effective in improving the respiratory and circulatory function disturbed by soman without the ability to increase significantly soman-inhibited acetylcholinesterase activity in all brain parts studied. 4 The efficacy of combined Panpal pretreatment and antidotal treatment against sublethal soman poisoning was not different from the efficacy of Panpal pretreatment or antidotal treatment alone. 5 The results of this investigation suggest that Panpal pretreatment as well as antidotal treatment are able to restore respiratory and circulatory function in soman-poisoned rats without significant reactivation of brain acetylcholinesterase.

  16. Abdominal emergencies in pediatrics.

    PubMed

    Coca Robinot, D; Liébana de Rojas, C; Aguirre Pascual, E

    2016-05-01

    Abdominal symptoms are among the most common reasons for pediatric emergency department visits, and abdominal pain is the most frequently reported symptom. Thorough history taking and physical examination can often reach the correct diagnosis. Knowing the abdominal conditions that are most common in each age group can help radiologists narrow the differential diagnosis. When imaging tests are indicated, ultrasonography is usually the first-line technique, enabling the diagnosis or adding relevant information with the well-known advantages of this technique. Nowadays, plain-film X-ray studies are reserved for cases in which perforation, bowel obstruction, or foreign body ingestion is suspected. It is also important to remember that abdominal pain can also occur secondary to basal pneumonia. CT is reserved for specific indications and in individual cases, for example, in patients with high clinical suspicion of abdominal disease and inconclusive findings at ultrasonography. We review some of the most common conditions in pediatric emergencies, the different imaging tests indicated in each case, and the imaging signs in each condition. Copyright © 2016 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  17. Minimal alteration in the ratio of circulatory fetal DNA to fetal corticotropin-releasing hormone mRNA level in preeclampsia.

    PubMed

    Zhong, Xiao Yan; Holzgreve, Wolfgang; Gebhardt, Stefan; Hillermann, Renate; Tofa, Kashefa Carelse; Gupta, Anurag Kumar; Huppertz, Berthold; Hahn, Sinuhe

    2006-01-01

    We have recently observed that fetal DNA and fetal corticotropin-releasing hormone (CRH) mRNA are associated with in vitro generated syncytiotrophoblast-derived microparticles, and that the ratio of fetal DNA to mRNA (CRH) varied according to whether the particles were derived by predominantly apoptotic, apo-necrotic or necrotic pathways. Hence, we examined whether these ratios varied in maternal plasma samples taken from normotensive and preeclamptic pregnancies in vivo. Maternal plasma samples were collected from 18 cases with preeclampsia and 29 normotensive term controls. Circulatory fetal CRH mRNA and DNA levels were quantified by real-time PCR and RT-PCR. Circulatory fetal mRNA and fetal DNA levels were significantly elevated in the preeclampsia study group when compared to normotensive controls. Alterations in the fetal mRNA to DNA ratio between the study and control groups were minimal, even when stratified into early (<34 weeks of gestation) and late (>34 weeks of gestation) onset preeclampsia. Our data suggest that although circulatory fetal DNA and mRNA levels are significantly elevated in preeclampsia, the ratios in maternal plasma are not dramatically altered. Copyright 2006 S. Karger AG, Basel.

  18. Development and evaluation of endurance test system for ventricular assist devices.

    PubMed

    Sumikura, Hirohito; Homma, Akihiko; Ohnuma, Kentaro; Taenaka, Yoshiyuki; Takewa, Yoshiaki; Mukaibayashi, Hiroshi; Katano, Kazuo; Tatsumi, Eisuke

    2013-06-01

    We developed a novel endurance test system that can arbitrarily set various circulatory conditions and has durability and stability for long-term continuous evaluation of ventricular assist devices (VADs), and we evaluated its fundamental performance and prolonged durability and stability. The circulation circuit of the present endurance test system consisted of a pulsatile pump with a small closed chamber (SCC), a closed chamber, a reservoir and an electromagnetic proportional valve. Two duckbill valves were mounted in the inlet and outlet of the pulsatile pump. The features of the circulation circuit are as follows: (1) the components of the circulation circuit consist of optimized industrial devices, giving durability; (2) the pulsatile pump can change the heart rate and stroke length (SL), as well as its compliance using the SCC. Therefore, the endurance test system can quantitatively reproduce various circulatory conditions. The range of reproducible circulatory conditions in the endurance test circuit was examined in terms of fundamental performance. Additionally, continuous operation for 6 months was performed in order to evaluate the durability and stability. The circulation circuit was able to set up a wide range of pressure and total flow conditions using the SCC and adjusting the pulsatile pump SL. The long-term continuous operation test demonstrated that stable, continuous operation for 6 months was possible without leakage or industrial device failure. The newly developed endurance test system demonstrated a wide range of reproducible circulatory conditions, durability and stability, and is a promising approach for evaluating the basic characteristics of VADs.

  19. Anthropomorphic cardiac ultrasound phantom.

    PubMed

    Smith, S W; Rinaldi, J E

    1989-10-01

    A new phantom is described which simulates the human cardiac anatomy for applications in ultrasound imaging, ultrasound Doppler, and color-flow Doppler imaging. The phantom consists of a polymer left ventricle which includes a prosthetic mitral and aortic valve and is connected to a mock circulatory loop. Aerated tap water serves as a blood simulating fluid and ultrasound contrast medium within the circulatory loop. The left ventricle is housed in a Lexan ultrasound visualization chamber which includes ultrasound viewing ports and acoustic absorbers. A piston pump connected to the visualization chamber by a single port pumps degassed water within the chamber which in turn pumps the left ventricle. Real-time ultrasound images and Doppler studies measure flow patterns through the valves and within the left ventricle.

  20. Determination of death after circulatory arrest by intensive care physicians: A survey of current practice in the Netherlands.

    PubMed

    Wind, Jentina; van Mook, Walther N K A; Dhanani, Sonny; van Heurn, Ernest W L

    2016-02-01

    Determination of death is an essential part of donation after circulatory death (DCD). We studied the current practices of determination of death after circulatory arrest by intensive care physicians in the Netherlands, the availability of guidelines, and the occurrence of the phenomenon of autoresuscitation. The Determination of Cardiac Death Practices in Intensive Care Survey was sent to all intensive care physicians. Fifty-five percent of 568 Dutch intensive care physicians responded. Most respondents learned death determination from clinical practice. The most commonly used tests for death determination were flat arterial line tracing, flat electrocardiogram (standard 3-lead electrocardiogram), and fixed and dilated pupils. Rarely used tests were absence pulse by echo Doppler, absent blood pressure by noninvasive monitoring, and unresponsiveness to painful stimulus. No diagnostic test or procedure was uniformly performed, but 80% of respondents perceived a need for standardization of death determination. Autoresuscitation was witnessed by 37%, after withdrawal of treatment or after unsuccessful resuscitation. Extensive variability in the practice of determining death after circulatory arrest exists, and a need for guidelines and standardization, especially if organ donation follows death, is reported. Autoresuscitation is reported; this observation requires attention in further prospective observational studies. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Infection-Induced Interaction between the Mosquito Circulatory and Immune Systems

    PubMed Central

    King, Jonas G.; Hillyer, Julián F.

    2012-01-01

    Insects counter infection with innate immune responses that rely on cells called hemocytes. Hemocytes exist in association with the insect's open circulatory system and this mode of existence has likely influenced the organization and control of anti-pathogen immune responses. Previous studies reported that pathogens in the mosquito body cavity (hemocoel) accumulate on the surface of the heart. Using novel cell staining, microdissection and intravital imaging techniques, we investigated the mechanism of pathogen accumulation in the pericardium of the malaria mosquito, Anopheles gambiae, and discovered a novel insect immune tissue, herein named periostial hemocytes, that sequesters pathogens as they flow with the hemolymph. Specifically, we show that there are two types of endocytic cells that flank the heart: periostial hemocytes and pericardial cells. Resident periostial hemocytes engage in the rapid phagocytosis of pathogens, and during the course of a bacterial or Plasmodium infection, circulating hemocytes migrate to the periostial regions where they bind the cardiac musculature and each other, and continue the phagocytosis of invaders. Periostial hemocyte aggregation occurs in a time- and infection dose-dependent manner, and once this immune process is triggered, the number of periostial hemocytes remains elevated for the lifetime of the mosquito. Finally, the soluble immune elicitors peptidoglycan and β-1,3-glucan also induce periostial hemocyte aggregation, indicating that this is a generalized and basal immune response that is induced by diverse immune stimuli. These data describe a novel insect cellular immune response that fundamentally relies on the physiological interaction between the insect circulatory and immune systems. PMID:23209421

  2. [The development tendencies of infusion pumps/syringe pumps].

    PubMed

    Zhang, Peng; Wang, Shu-Yi; Yu, Chuan-Yi; Zhang, Min-Yan

    2009-07-01

    Through the investigation about the current infusion pumps, the development tendencies of the next generation infusion pumps/Syringe Pumps with regarding to human-factors, practicality and application under MRI (Magnetic resonance imaging) were put forward.

  3. Abdominal Complications after Severe Burns

    DTIC Science & Technology

    2009-05-01

    abdominal compartment syndrome, schemic bowel, biliary disease, peptic ulcer disease and astritis requiring laparotomy, small bowel obstruction, rimary fungal...abdominal complications was 25%, with Curl- ng’s ulcer the most common malady (54% of the total), ollowed by esophageal lesions (17%), hemorrhagic...complications in- luded trauma exploratory laparotomy, abdominal com- artment syndrome, ischemic bowel, biliary disease, peptic lcer disease and gastritis, large

  4. Circulatory shear flow alters the viability and proliferation of circulating colon cancer cells

    NASA Astrophysics Data System (ADS)

    Fan, Rong; Emery, Travis; Zhang, Yongguo; Xia, Yuxuan; Sun, Jun; Wan, Jiandi

    2016-06-01

    During cancer metastasis, circulating tumor cells constantly experience hemodynamic shear stress in the circulation. Cellular responses to shear stress including cell viability and proliferation thus play critical roles in cancer metastasis. Here, we developed a microfluidic approach to establish a circulatory microenvironment and studied circulating human colon cancer HCT116 cells in response to a variety of magnitude of shear stress and circulating time. Our results showed that cell viability decreased with the increase of circulating time, but increased with the magnitude of wall shear stress. Proliferation of cells survived from circulation could be maintained when physiologically relevant wall shear stresses were applied. High wall shear stress (60.5 dyne/cm2), however, led to decreased cell proliferation at long circulating time (1 h). We further showed that the expression levels of β-catenin and c-myc, proliferation regulators, were significantly enhanced by increasing wall shear stress. The presented study provides a new insight to the roles of circulatory shear stress in cellular responses of circulating tumor cells in a physiologically relevant model, and thus will be of interest for the study of cancer cell mechanosensing and cancer metastasis.

  5. Description, validation, and modification of the Guyton model for space-flight applications. Part A. Guyton model of circulatory, fluid and electrolyte control. Part B. Modification of the Guyton model for circulatory, fluid and electrolyte control

    NASA Technical Reports Server (NTRS)

    Leonard, J. I.

    1985-01-01

    The mathematical model that has been a cornerstone for the systems analysis of space-flight physiological studies is the Guyton model describing circulatory, fluid and electrolyte regulation. The model and the modifications that are made to permit simulation and analysis of the stress of weightlessness are described.

  6. Surface Electromyographic Activity of the Abdominal Muscles During Pelvic-Tilt and Abdominal-Hollowing Exercises.

    PubMed

    Drysdale, Cheri L.; Earl, Jennifer E.; Hertel, Jay

    2004-03-01

    OBJECTIVE: To investigate surface electromyographic (EMG) activity of the rectus abdominus and external oblique abdominus muscles during pelvic-tilt and abdominal-hollowing exercises performed in different positions. DESIGN AND SETTING: 2 x 3 (exercise by position) within-subjects design with repeated measures on both factors. All testing was performed in a university laboratory. SUBJECTS: Twenty-six healthy, active young adult females. MEASUREMENTS: Surface EMG activity was recorded from the left and right rectus abdominus and external oblique muscles while the 2 exercises (pelvic tilt and abdominal hollowing) were performed in different positions (standard, legs supported, and legs unsupported). The standard position was supine in the crook-lying position, the supported position was with hips and knees flexed to 90 degrees and legs supported on a platform, and the unsupported position was with hips and knees flexed to 90 degrees without external support. Peak EMG activity was normalized to a maximum voluntary isometric contraction for each muscle. RESULTS: For the rectus abdominus, there was an interaction between position and activity. Abdominal hollowing produced significantly less activity than the pelvic tilt in all positions. The difference between the 2 exercises with the legs unsupported was of a greater magnitude than the other 2 positions. For the external obliques, there was significantly lower activity during the abdominal hollowing compared with the pelvic tilting. The greatest muscle activity occurred with the legs-unsupported position during both exercises. CONCLUSIONS: Abdominal-hollowing exercises produced less rectus abdominus and external oblique activity than pelvic-tilting exercises. Abdominal hollowing may be performed with minimal activation of the large global abdominal muscles.

  7. The association of fever with transfusion-associated circulatory overload.

    PubMed

    Parmar, N; Pendergrast, J; Lieberman, L; Lin, Y; Callum, J; Cserti-Gazdewich, C

    2017-01-01

    Fever is described in transfusion-associated circulatory overload (TACO), reflecting either comprehensive haemovigilance or an inflammatory pathobiology (such as congestion-associated atheroma disruptions). Hospital haemovigilance data (1/1/2010-31/12/2012) were reviewed for TACO cases (frequency and mode of referral). TACO with or without fever (TACO+F/-F) was examined for its association with patient age (as a surrogate for atheroma burden) and product age (as a surrogate for storage-related pyrogens). Fever in allergic transfusion reactions was also compared. Of 972 reactions, 107 suspected cases of TACO (11%) were seen. TACO+F vs. TACO-F occurred in 42·1 vs. 57·9%, respectively. TACO+F cases were discovered in referrals to investigate either a fever (in 47·1%) or dyspnoea (in 52·9%). Among TACO+F cases, 24·4% had already been febrile, whereas 75·6% exhibited a new reaction-associated fever. After excluding preexisting fevers, TACO+F occurred in 31·8% of TACO, compared with 8·2% of allergic reactions with fever, for an odds ratio of 5·2 (2·9-9·4 [95% CI]), P < 0·001. TACO+F/TACO-F showed no difference in median host age (69 vs. 64 years, P = 0·3), RBC age (22 days +F/-F, P = 0·9) or severity. Transfusion-associated circulatory overload disproportionately exhibits fever compared with allergic reactions. However, TACO+F did not associate with patient or product age, nor reflect severity. To better understand TACO+F, the fever-congestion sequence merits attention. Further study is needed to see whether TACO+F occurs as reproducibly elsewhere, and in association with atherosclerosis in a better characterized cohort. © 2016 International Society of Blood Transfusion.

  8. Blunt abdominal trauma in children.

    PubMed

    Schonfeld, Deborah; Lee, Lois K

    2012-06-01

    This review will examine the current evidence regarding pediatric blunt abdominal trauma and the physical exam findings, laboratory values, and radiographic imaging associated with the diagnosis of intra-abdominal injuries (IAI), as well as review the current literature on pediatric hollow viscus injuries and emergency department disposition after diagnosis. The importance of the seat belt sign on physical examination and screening laboratory data remains controversial, although screening hepatic enzymes are recommended in the evaluation of nonaccidental trauma to identify occult abdominal organ injuries. Focused Assessment with Sonography for Trauma (FAST) has modest sensitivity for hemoperitoneum and IAI in the pediatric trauma patient. Patients with concern for undiagnosed IAI, including bowel injury, may be considered for hospital admission and serial abdominal exams without an increased risk of complications, if an exploratory laparotomy is not performed emergently. Although the FAST exam is not recommended as the sole screening tool to rule out IAI in hemodynamically stable trauma patients, it may be used in conjunction with the physical exam and laboratory findings to identify children at risk for IAI. Children with a normal physical exam and normal abdominal CT may not require routine hospitalization after blunt abdominal trauma.

  9. Pump tank divider plate for sump suction sodium pumps

    DOEpatents

    George, John A.; Nixon, Donald R.

    1977-01-01

    A circular plate extends across the diameter of "sump suction" pump, with a close clearance between the edge of the plate and the wall of the pump tank. The plate is located above the pump impeller, inlet and outlet flow nozzles but below the sodium free surface and effectively divides the pump tank into two separate chambers. On change of pump speed, the close fitting flow restriction plate limits the rate of flow into or out of the upper chamber, thereby minimizing the rate of level change in the tank and permitting time for the pump cover gas pressure to be varied to maintain an essentially constant level.

  10. Hemodynamic response to exercise and head-up tilt of patients implanted with a rotary blood pump: a computational modeling study.

    PubMed

    Lim, Einly; Salamonsen, Robert Francis; Mansouri, Mahdi; Gaddum, Nicholas; Mason, David Glen; Timms, Daniel L; Stevens, Michael Charles; Fraser, John; Akmeliawati, Rini; Lovell, Nigel Hamilton

    2015-02-01

    The present study investigates the response of implantable rotary blood pump (IRBP)-assisted patients to exercise and head-up tilt (HUT), as well as the effect of alterations in the model parameter values on this response, using validated numerical models. Furthermore, we comparatively evaluate the performance of a number of previously proposed physiologically responsive controllers, including constant speed, constant flow pulsatility index (PI), constant average pressure difference between the aorta and the left atrium, constant average differential pump pressure, constant ratio between mean pump flow and pump flow pulsatility (ratioP I or linear Starling-like control), as well as constant left atrial pressure ( P l a ¯ ) control, with regard to their ability to increase cardiac output during exercise while maintaining circulatory stability upon HUT. Although native cardiac output increases automatically during exercise, increasing pump speed was able to further improve total cardiac output and reduce elevated filling pressures. At the same time, reduced venous return associated with upright posture was not shown to induce left ventricular (LV) suction. Although P l a ¯ control outperformed other control modes in its ability to increase cardiac output during exercise, it caused a fall in the mean arterial pressure upon HUT, which may cause postural hypotension or patient discomfort. To the contrary, maintaining constant average pressure difference between the aorta and the left atrium demonstrated superior performance in both exercise and HUT scenarios. Due to their strong dependence on the pump operating point, PI and ratioPI control performed poorly during exercise and HUT. Our simulation results also highlighted the importance of the baroreflex mechanism in determining the response of the IRBP-assisted patients to exercise and postural changes, where desensitized reflex response attenuated the percentage increase in cardiac output during exercise and

  11. Alternative backing up pump for turbomolecular pumps

    DOEpatents

    Myneni, Ganapati Rao

    2003-04-22

    As an alternative to the use of a mechanical backing pump in the application of wide range turbomolecular pumps in ultra-high and extra high vacuum applications, palladium oxide is used to convert hydrogen present in the evacuation stream and related volumes to water with the water then being cryo-pumped to a low pressure of below about 1.e.sup.-3 Torr at 150.degree. K. Cryo-pumping is achieved using a low cost Kleemenco cycle cryocooler, a somewhat more expensive thermoelectric cooler, a Venturi cooler or a similar device to achieve the required minimization of hydrogen partial pressure.

  12. 9 CFR 309.4 - Livestock showing symptoms of certain metabolic, toxic, nervous, or circulatory disturbances...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... diseases. 309.4 Section 309.4 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF..., toxic, nervous, or circulatory disturbances, nutritional imbalances, or infectious or parasitic diseases... the animal is, in fact, infected with such disease. If it is found on such tests to be infected, the...

  13. 9 CFR 309.4 - Livestock showing symptoms of certain metabolic, toxic, nervous, or circulatory disturbances...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... diseases. 309.4 Section 309.4 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF..., toxic, nervous, or circulatory disturbances, nutritional imbalances, or infectious or parasitic diseases... the animal is, in fact, infected with such disease. If it is found on such tests to be infected, the...

  14. 9 CFR 309.4 - Livestock showing symptoms of certain metabolic, toxic, nervous, or circulatory disturbances...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... diseases. 309.4 Section 309.4 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF..., toxic, nervous, or circulatory disturbances, nutritional imbalances, or infectious or parasitic diseases... the animal is, in fact, infected with such disease. If it is found on such tests to be infected, the...

  15. 9 CFR 309.4 - Livestock showing symptoms of certain metabolic, toxic, nervous, or circulatory disturbances...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... diseases. 309.4 Section 309.4 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF..., toxic, nervous, or circulatory disturbances, nutritional imbalances, or infectious or parasitic diseases... the animal is, in fact, infected with such disease. If it is found on such tests to be infected, the...

  16. 9 CFR 309.4 - Livestock showing symptoms of certain metabolic, toxic, nervous, or circulatory disturbances...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... diseases. 309.4 Section 309.4 Animals and Animal Products FOOD SAFETY AND INSPECTION SERVICE, DEPARTMENT OF..., toxic, nervous, or circulatory disturbances, nutritional imbalances, or infectious or parasitic diseases... the animal is, in fact, infected with such disease. If it is found on such tests to be infected, the...

  17. Liquid metal pump

    DOEpatents

    Pennell, William E.

    1982-01-01

    The liquid metal pump comprises floating seal rings and attachment of the pump diffuser to the pump bowl for isolating structural deflections from the pump shaft bearings. The seal rings also eliminate precision machining on large assemblies by eliminating the need for a close tolerance fit between the mounting surfaces of the pump and the seals. The liquid metal pump also comprises a shaft support structure that is isolated from the pump housing for better preservation of alignment of shaft bearings. The shaft support structure also allows for complete removal of pump internals for inspection and repair.

  18. Use of Mechanical Circulatory Support in Percutaneous Coronary Intervention in the United States

    PubMed Central

    Khera, Rohan; Cram, Peter; Vaughan-Sarrazin, Mary; Horwitz, Phillip A.; Girotra, Saket

    2015-01-01

    Percutaneous ventricular assist devices (PVADs) and intra-aortic balloon pump (IABP) are used to provide mechanical circulatory support (MCS) for high-risk percutaneous coronary intervention (PCI). Contemporary trends in their utilization and impact on in-hospital mortality are not known. Using the National Inpatient Sample (2004–2012), we identified 5031 patients who received a PVAD and 122,333 who received an IABP on the same day as PCI using ICD9 codes. Utilization of MCS increased from 1.3% of all PCIs in 2004 to 3.4% in 2012 (P trend<0.001), with increase in the use of both PVAD (<1/10000 PCIs [2004–2007] to 38/10000 [2012]) and IABP (132/10000 PCIs [2004] to 299/10000[2012] P<0.0001 for both). PVAD recipients were older (69 vs. 65 years), more likely to have heart failure (68% vs. 41%), chronic kidney disease (27% vs. 11%, P<0.001 for all), and be admitted electively (30% vs. 11%), but less likely to have AMI (52% vs. 90%), cardiogenic shock (23% vs. 50%) or need mechanical ventilation (16% vs. 29%) compared to IABP recipients. Unadjusted in-hospital mortality was lower in PVAD compared to IABP recipients (12.8% vs. 20.9%, P<0.001). However, in propensity-matched analyses (1:2), in-hospital mortality was similar in both groups (odds ratio 0.88, 95% CI 0.70–1.09). In conclusion, there has been a marked increase in the utilization of MCS in patients undergoing PCI. Unadjusted mortality with use of PVADs is lower than IABP but may be due to their selective use in lower-risk patients. Randomized trials are necessary to establish their effectiveness in supporting high-risk PCI. PMID:26547292

  19. ABO blood group antibody levels in infants exposed to mechanical circulatory support.

    PubMed

    Guynes, Anthony; Delaney, Meghan; McMullan, David M; Townsend-McCall, Dee; Kemna, Mariska; Boucek, Robert; Law, Yuk M

    2014-01-01

    ABO sensitization is a barrier to ABO-incompatible heart transplantation in infants. We investigate the development of ABO antibodies in infants with and without mechanical circulatory support (MCS) during their waiting period. Although the proportion of patients with antibodies was similar between the groups, the median age at antibody detection was only 9 days (6-198) for MCS vs. 223 days (28-367) for non-MCS patients (P = 0.028), suggesting MCS is associated with earlier ABO antibody detection.

  20. Low-frequency dynamics of autonomic regulation of circulatory system in healthy subjects

    NASA Astrophysics Data System (ADS)

    Skazkina, V. V.; Borovkova, E. I.; Galushko, T. A.; Khorev, V. S.; Kiselev, A. R.

    2018-04-01

    The paper is devoted to the analysis of dynamic of interactions between signals of autonomic circulatory regulation. We investigated two-hour experimental records of 30 healthy people. Phase synchronization was studied using the signals of the electrocardiogram and the photoplethysmogram of vessels. We found the presence of long synchronous intervals in some subjects. For analysis of the dynamic we calculated autocorrelation functions. The analysis made it possible to reveal indirect signs of the influence of the humoral regulation system.

  1. Surface Electromyographic Activity of the Abdominal Muscles During Pelvic-Tilt and Abdominal-Hollowing Exercises

    PubMed Central

    Drysdale, Cheri L.; Earl, Jennifer E.

    2004-01-01

    Objective: To investigate surface electromyographic (EMG) activity of the rectus abdominus and external oblique abdominus muscles during pelvic-tilt and abdominal-hollowing exercises performed in different positions. Design and Setting: 2 × 3 (exercise by position) within-subjects design with repeated measures on both factors. All testing was performed in a university laboratory. Subjects: Twenty-six healthy, active young adult females. Measurements: Surface EMG activity was recorded from the left and right rectus abdominus and external oblique muscles while the 2 exercises (pelvic tilt and abdominal hollowing) were performed in different positions (standard, legs supported, and legs unsupported). The standard position was supine in the crook-lying position, the supported position was with hips and knees flexed to 90° and legs supported on a platform, and the unsupported position was with hips and knees flexed to 90° without external support. Peak EMG activity was normalized to a maximum voluntary isometric contraction for each muscle. Results: For the rectus abdominus, there was an interaction between position and activity. Abdominal hollowing produced significantly less activity than the pelvic tilt in all positions. The difference between the 2 exercises with the legs unsupported was of a greater magnitude than the other 2 positions. For the external obliques, there was significantly lower activity during the abdominal hollowing compared with the pelvic tilting. The greatest muscle activity occurred with the legs-unsupported position during both exercises. Conclusions: Abdominal-hollowing exercises produced less rectus abdominus and external oblique activity than pelvic-tilting exercises. Abdominal hollowing may be performed with minimal activation of the large global abdominal muscles. PMID:15085209

  2. OSCILLATORY PUMP

    DOEpatents

    Underwood, N.

    1958-09-23

    This patent relates to a pump suitable fur pumping highly corrosive gases wherein no lubricant is needed in the pumping chamber thus eliminating possible contamination sources. The chamber contains a gas inlet and outlet in each side, with a paddle like piston suspended by a sylphon seal between these pcrts. An external arrangement causes the paddle to oscillate rapidly between the ports, alternately compressing and exhausting the gas trapped on each side of the paddle. Since the paddle does nnt touch the chamber sides at any point, no lubricant is required. This pump is useful for pumping large quantities of uranium hexafluorine.

  3. Identification and Management of Pump Thrombus in the HeartWare Left Ventricular Assist Device System: A Novel Approach Using Log File Analysis.

    PubMed

    Jorde, Ulrich P; Aaronson, Keith D; Najjar, Samer S; Pagani, Francis D; Hayward, Christopher; Zimpfer, Daniel; Schlöglhofer, Thomas; Pham, Duc T; Goldstein, Daniel J; Leadley, Katrin; Chow, Ming-Jay; Brown, Michael C; Uriel, Nir

    2015-11-01

    The study sought to characterize patterns in the HeartWare (HeartWare Inc., Framingham, Massachusetts) ventricular assist device (HVAD) log files associated with successful medical treatment of device thrombosis. Device thrombosis is a serious adverse event for mechanical circulatory support devices and is often preceded by increased power consumption. Log files of the pump power are easily accessible on the bedside monitor of HVAD patients and may allow early diagnosis of device thrombosis. Furthermore, analysis of the log files may be able to predict the success rate of thrombolysis or the need for pump exchange. The log files of 15 ADVANCE trial patients (algorithm derivation cohort) with 16 pump thrombus events treated with tissue plasminogen activator (tPA) were assessed for changes in the absolute and rate of increase in power consumption. Successful thrombolysis was defined as a clinical resolution of pump thrombus including normalization of power consumption and improvement in biochemical markers of hemolysis. Significant differences in log file patterns between successful and unsuccessful thrombolysis treatments were verified in 43 patients with 53 pump thrombus events implanted outside of clinical trials (validation cohort). The overall success rate of tPA therapy was 57%. Successful treatments had significantly lower measures of percent of expected power (130.9% vs. 196.1%, p = 0.016) and rate of increase in power (0.61 vs. 2.87, p < 0.0001). Medical therapy was successful in 77.7% of the algorithm development cohort and 81.3% of the validation cohort when the rate of power increase and percent of expected power values were <1.25% and 200%, respectively. Log file parameters can potentially predict the likelihood of successful tPA treatments and if validated prospectively, could substantially alter the approach to thrombus management. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  4. Intra-abdominal abscess demonstrating an unusually large intra-abdominal pattern on an indium-111 leukocyte scan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Black, R.R.; Fernandez-Ulloa, M.; ter Penning, B.

    1988-12-01

    Indium-111 WBC imaging of a patient with occult septicemia revealed a large focal pattern of radiopharmaceutical distribution within the abdominal cavity at 24 hours post radiopharmaceutical administration. This finding was felt to represent a large intra-abdominal abscess. A five liter peritoneal abscess was found at surgery. This case illustrates an unusual presentation of an intra-abdominal abscess.

  5. Temporary Abdominal Closure Combined With an Irrigating System Utilizing Hypochlorous Acid Solution to Decrease Abdominal Mucopurulence

    PubMed Central

    Matthews, Marc R.; Quan, Asia N.; Weir, Alexandra S.; Foster, Kevin N.; Caruso, Daniel M.

    2018-01-01

    Introduction: Leaving the abdominal cavity open is a well-described and frequently utilized technique in the treatment of severe intra-abdominal sepsis. Irrigation through a negative pressure wound therapy device is a technique employed to assist in the closure of wounds as well as the reduction of bacterial contamination. Furthermore, hypochlorous acid has been found to be safe and effective in microorganismal elimination from extremity wounds. There is no literature regarding the infusion of hypochlorous solution into the abdominal cavity for intra-abdominal sepsis or mucopurulent abscesses or biofilm. Objectives: A 47-year-old man with granulomatosis polyangiitis was started on weekly rituximab. After 4 infusions, skin sloughing, ultimately diagnosed as toxic epidermal necrolysis, developed. During the hospital course, he developed sepsis and bowel perforation necessitating an exploratory laparotomy. The abdomen was left open with a temporary abdominal closure using the Abthera open abdomen negative wound therapy device; however, the abdomen remained infected with visually diffuse, thickening mucopurulence despite multiple washouts. Therefore, a VAC Vera-Flo irrigation device was combined with the Abthera open abdomen negative wound therapy device and cyclical irrigation of hypochlorous acid. After 72 hours, the purulence visually was improved and no adverse events were recorded with the placement of intra-abdominal hypochlorous acid. Conclusions: The combination of two medical devices for the intra-abdominal instillation of irrigation is considered “off-label use” from the manufacturer's recommendations. In addition, the repeated instillation of hypochlorous acid solution has not been described but was noted to have visually decreased the contaminated effluent within the intra-abdominal fluid. PMID:29527250

  6. Rotating and positive-displacement pumps for low-thrust rocket engines. Volume 1: Pump Evaluation and design. [of centrifugal pumps

    NASA Technical Reports Server (NTRS)

    Macgregor, C.; Csomor, A.

    1974-01-01

    Rotating and positive displacement pumps of various types were studied for pumping liquid fluorine for low-thrust, high-performance rocket engines. Included in the analysis were: centrifugal, pitot, Barske, Tesla, drag, gear, vane, axial piston, radial piston, diaphragm, and helirotor pump concepts. The centrifugal pump and the gear pump were selected and these were carried through detailed design and fabrication. Mechanical difficulties were encountered with the gear pump during the preliminary tests in Freon-12. Further testing and development was therefore limited to the centrifugal pump. Tests on the centrifugal pump were conducted in Freon-12 to determine the hydrodynamic performance and in liquid fluorine to demonstrate chemical compatibility.

  7. 20. Station Unwatering Pumps and Sump Pump, view to the ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    20. Station Unwatering Pumps and Sump Pump, view to the north. The station unwatering pumps are the two large units in the center and right foreground of photograph and are marked with the numbers 1 and 2. The sump pump is the smaller unit in left foreground of photograph. These pumps are used for unwatering the draft chests for maintenance. Note the draft tube unwatering valve visible in background between the two unwatering pumps. - Washington Water Power Clark Fork River Noxon Rapids Hydroelectric Development, Powerhouse, South bank of Clark Fork River at Noxon Rapids, Noxon, Sanders County, MT

  8. Low molecular weight fucoidan attenuates experimental abdominal aortic aneurysm through interfering the leukocyte-endothelial cells interaction.

    PubMed

    Zhou, Min; Ding, Yong; Cai, Liang; Wang, Yonggang; Lin, Changpo; Shi, Zhenyu

    2018-05-01

    Low molecular weight fucoidan (LMWF) is a sulfated polysaccharide extracted from Saccharina Japonica that presents high affinity for P-selectin and abolish selectin-dependent recruitment of leukocytes. We hypothesized that dietary intake of LMWF, as a competitive binding agent of P‑selectin, could limit the inflammatory infiltration and aneurysmal growth in an Angiotensin II‑induced abdominal aortic aneurysm (AAA) mouse model. The Gene Expression Omnibus database was used for gene expressions and gene set enrichment analysis. Kyoto Encyclopedia of Genes and Genomes pathway enrichment analysis showed that focal adhesion was involved in the development of AAA. However, dietary intake of LMWF could limit the enlargement of AAA, decreasing maximal aortic diameter and preserving elastin lamellae. Although LMWF did not decrease the circulatory monocytes count and lower the expression of P‑selectin in endothelium, it reduced macrophages infiltration in media and adventitia. Furthermore, matrix metalloproteinase expression was markedly downregulated, accompanied with reduced expression of inflammatory mediators, including interleukin 1β, tumor necrosis factor‑α and monocyte chemotactic protein‑1. The present study revealed a novel target for the treatment of AAA and the anti‑inflammatory effects of LMWF.

  9. Dynamics of Short-Term Phosphorus Uptake by Intact Mycorrhizal and Non-mycorrhizal Maize Plants Grown in a Circulatory Semi-Hydroponic Cultivation System.

    PubMed

    Garcés-Ruiz, Mónica; Calonne-Salmon, Maryline; Plouznikoff, Katia; Misson, Coralie; Navarrete-Mier, Micaela; Cranenbrouck, Sylvie; Declerck, Stéphane

    2017-01-01

    A non-destructive cultivation system was developed to study the dynamics of phosphorus (Pi) uptake by mycorrhizal and non-mycorrhizal maize plantlets. The system consisted of a plant container connected via silicon tubes to a glass bottle containing a nutrient solution supplemented with Pi. The nutrient solution is pumped with a peristaltic pump to the upper part of the container via the silicon tubes and the solution percolate through the plantlet container back into the glass bottle. Pi is sampled from the glass bottle at regular intervals and concentration evaluated. Maize plantlets were colonized by the AMF Rhizophagus irregularis MUCL 41833 and Pi uptake quantified at fixed intervals (9, 21, and 42 h) from the depletion of the Pi in the nutrient solution flowing through the plantlets containers. Plants and fungus grew well in the perlite substrate. The concentration of Pi in the bottles followed an almost linear decrease over time, demonstrating a depletion of Pi in the circulating solution and a concomitant uptake/immobilization by the plantlet-AMF associates in the containers. The Pi uptake rate was significantly increased in the AMF-colonized plantlets (at 9 and 21 h) as compared to non-colonized plantlets, although no correlation was noticed with plant growth or P accumulation in shoots. The circulatory semi-hydroponic cultivation system developed was adequate for measuring Pi depletion in a nutrient solution and by corollary Pi uptake/immobilization by the plant-AMF associates. The measurements were non-destructive so that the time course of Pi uptake could be monitored without disturbing the growth of the plant and its fungal associate. The system further opens the door to study the dynamics of other micro and macro-nutrients as well as their uptake under stressed growth conditions such as salinity, pollution by hydrocarbon contaminants or potential toxic elements.

  10. ELECTROMAGNETIC PUMP

    DOEpatents

    Pulley, O.O.

    1954-08-17

    This patent reiates to electromagnetic pumps for electricity-conducting fluids and, in particular, describes several modifications for a linear conduction type electromagnetic interaction pump. The invention resides in passing the return conductor for the current traversing the fiuid in the duct back through the gap in the iron circuit of the pump. Both the maximum allowable pressure and the efficiency of a linear conduction electromagnetic pump are increased by incorporation of the present invention.

  11. Cardiac and circulatory assessment in intensive care units.

    PubMed

    McGrath, A; Cox, C L

    1998-12-01

    As healthcare delivery changes in critical care, nursing continues to evolve and develop. Nursing skills are expanding to incorporate skills once seen as the remit of the medical profession. Nurses are now equipping themselves with the skills and knowledge that can enhance the care they provide to their patients. Assessment of patients is a major role in nursing and, by expanding assessment skills, nurses can ensure that patients receive the care most appropriate to their needs. Nurses in critical care settings are well placed to carry out a more detailed assessment, which can help to focus nursing care. This article describes the step-by-step process of undertaking a full and comprehensive cardiac and circulatory assessment in a clinical setting. It identifies many of the problems that patients may have and the signs that the nurse may note whilst undertaking the assessment.

  12. [Diagnostic imaging and acute abdominal pain].

    PubMed

    Liljekvist, Mads Svane; Pommergaard, Hans-Christian; Burcharth, Jakob; Rosenberg, Jacob

    2015-01-19

    Acute abdominal pain is a common clinical condition. Clinical signs and symptoms can be difficult to interpret, and diagnostic imaging may help to identify intra-abdominal disease. Conventional X-ray, ultrasound (US) and computed tomography (CT) of the abdomen vary in usability between common surgical causes of acute abdominal pain. Overall, conventional X-ray cannot confidently diagnose or rule out disease. US and CT are equally trustworthy for most diseases. US with subsequent CT may enhance diagnostic precision. Magnetic resonance seems promising for future use in acute abdominal imaging.

  13. Circulatory Support with Venoarterial ECMO Unsuccessful in Aiding Endogenous Diltiazem Clearance after Overdose.

    PubMed

    Frazee, Erin N; Lee, Sarah J; Kalimullah, Ejaaz A; Personett, Heather A; Nelson, Darlene R

    2014-01-01

    Introduction. In cardiovascular collapse from diltiazem poisoning, extracorporeal membrane oxygenation (ECMO) may offer circulatory support sufficient to preserve endogenous hepatic drug clearance. Little is known about patient outcomes and diltiazem toxicokinetics in this setting. Case Report. A 36-year-old woman with a history of myocardial bridging syndrome presented with chest pain for which she self-medicated with 2.4 g of sustained release diltiazem over the course of 8 hours. Hemodynamics and mentation were satisfactory on presentation, but precipitously deteriorated after ICU transfer. She was given fluids, calcium, vasopressors, glucagon, high-dose insulin, and lipid emulsion. Due to circulatory collapse and multiorgan failure including ischemic hepatopathy, she underwent transvenous pacing and emergent initiation of venoarterial ECMO. The peak diltiazem level was 13150 ng/mL (normal 100-200 ng/mL) and it remained elevated at 6340 ng/mL at hour 90. Unfortunately, the patient developed multiple complications which resulted in her death on ICU day 9. Conclusion. This case describes the unsuccessful use of ECMO for diltiazem intoxication. Although past reports suggest that support with ECMO may facilitate endogenous diltiazem clearance, it may be dependent on preserved hepatic function at the time of cannulation, a factor not present in this case.

  14. Spectral line intensity irreversibility in circulatory plasma magnetization processes

    NASA Astrophysics Data System (ADS)

    Qu, Z. Q.; Dun, G. T.

    2012-01-01

    Spectral line intensity variation is found to be irreversible in circulatory plasma magnetization process by experiments described in this paper, i.e., the curves illustrating spectral line photon fluxes irradiated from a light source immerged in a magnetic field by increasing the magnetic induction cannot be reproduced by decreasing the magnetic induction within the errors. There are two plasma magnetization patterns found. One shows that the intensities are greater at the same magnetic inductions during the magnetic induction decreasing process after the increasing, and the other gives the opposite effect. This reveals that the magneto-induced excitation and de-excitation process is irreversible like ferromagnetic magnetization. But the two irreversible processes are very different in many aspects stated in the text.

  15. Colloids Versus Albumin in Large Volume Paracentesis to Prevent Circulatory Dysfunction: Evidence-based Case Report.

    PubMed

    Widjaja, Felix F; Khairan, Paramita; Kamelia, Telly; Hasan, Irsan

    2016-04-01

    Large volume paracentesis may cause paracentesis induced circulatory dysfunction (PICD). Albumin is recommended to prevent this abnormality. Meanwhile, the price of albumin is too expensive and there should be another alternative that may prevent PICD. This report aimed to compare albumin to colloids in preventing PICD. Search strategy was done using PubMed, Scopus, Proquest, dan Academic Health Complete from EBSCO with keywords of "ascites", "albumin", "colloid", "dextran", "hydroxyethyl starch", "gelatin", and "paracentesis induced circulatory dysfunction". Articles was limited to randomized clinical trial and meta-analysis with clinical question of "In hepatic cirrhotic patient undergone large volume paracentesis, whether colloids were similar to albumin to prevent PICD". We found one meta-analysis and four randomized clinical trials (RCT). A meta analysis showed that albumin was still superior of which odds ratio 0.34 (0.23-0.51). Three RCTs showed the same results and one RCT showed albumin was not superior than colloids. We conclude that colloids could not constitute albumin to prevent PICD, but colloids still have a role in patient who undergone paracentesis less than five liters.

  16. PUMPS

    DOEpatents

    Thornton, J.D.

    1959-03-24

    A pump is described for conveving liquids, particure it is not advisable he apparatus. The to be submerged in the liquid to be pumped, a conduit extending from the high-velocity nozzle of the injector,and means for applying a pulsating prcesure to the surface of the liquid in the conduit, whereby the surface oscillates between positions in the conduit. During the positive half- cycle of an applied pulse liquid is forced through the high velocity nozzle or jet of the injector and operates in the manner of the well known water injector and pumps liquid from the main intake to the outlet of the injector. During the negative half-cycle of the pulse liquid flows in reverse through the jet but no reverse pumping action takes place.

  17. Abdominal cocoon secondary to disseminated tuberculosis

    PubMed Central

    Puppala, Radha; Sripathi, Smiti; Kadavigere, Rajagopal; Koteshwar, Prakashini; Singh, Jyoti

    2014-01-01

    Abdominal cocoon, also known as sclerosing encapsulating peritonitis, represents a rare entity where a variable length of the small bowel is enveloped by a fibrocollagenous membrane giving the appearance of a cocoon. It may be asymptomatic and is often diagnosed incidentally at laparotomy. We present a rare case of abdominal cocoon due to abdominal tuberculosis. PMID:25239980

  18. Abdominal Pain in the Geriatric Patient.

    PubMed

    Magidson, Phillip D; Martinez, Joseph P

    2016-08-01

    With an aging population, emergency department clinicians can expect an increase in geriatric patients presenting with abdominal pain. Compared with younger patients, this patient population is less likely to present with classic symptoms, physical examination findings, and laboratory values of abdominal disease. However, the morbidity and mortality associated with elderly patients presenting with abdominal pathologic conditions are significant. For this reason, the clinician must be familiar with some subtle and not so subtle differences when caring for the geriatric patient with abdominal pain to ensure timely diagnosis and appropriate treatment. Copyright © 2016 Elsevier Inc. All rights reserved.

  19. Imbalance of arginine and asymmetric dimethylarginine is associated with markers of circulatory failure, organ failure and mortality in shock patients.

    PubMed

    Visser, Marlieke; Vermeulen, Mechteld A R; Richir, Milan C; Teerlink, Tom; Houdijk, Alexander P J; Kostense, Piet J; Wisselink, Willem; de Mol, Bas A J M; van Leeuwen, Paul A M; Oudemans-van Straaten, Heleen M

    2012-05-01

    In shock, organ perfusion is of vital importance because organ oxygenation is at risk. NO, the main endothelial-derived vasodilator, is crucial for organ perfusion and coronary patency. The availability of NO might depend on the balance between a substrate (arginine) and an inhibitor (asymmetric dimethylarginine; ADMA) of NO synthase. Therefore, we investigated the relationship of arginine, ADMA and their ratio with circulatory markers, disease severity, organ failure and mortality in shock patients. In forty-four patients with shock (cardiogenic n 17, septic n 27), we prospectively measured plasma arginine and ADMA at intensive care unit admission, Acute Physiology and Chronic Health Evaluation (APACHE) II-(predicted mortality) and Sequential Organ Failure Assessment (SOFA) score, and circulatory markers to investigate their relationship. Arginine concentration was decreased (34·6 (SD 17·9) μmol/l) while ADMA concentration was within the normal range (0·46 (SD 0·18) μmol/l), resulting in a decrease in the arginine:ADMA ratio. The ratio correlated with several circulatory markers (cardiac index, disseminated intravascular coagulation, bicarbonate, lactate and pH), APACHE II and SOFA score, creatine kinase and glucose. The arginine:ADMA ratio showed an association (OR 0·976, 95 % CI 0·963, 0·997, P = 0·025) and a diagnostic accuracy (area under the curve 0·721, 95 % CI 0·560, 0·882, P = 0·016) for hospital mortality, whereas the arginine or ADMA concentration alone or APACHE II-predicted mortality failed to do so. In conclusion, in shock patients, the imbalance of arginine and ADMA is related to circulatory failure, organ failure and disease severity, and predicts mortality. We propose a pathophysiological mechanism in shock: the imbalance of arginine and ADMA contributes to endothelial and cardiac dysfunction resulting in poor organ perfusion and organ failure, thereby increasing the risk of death.

  20. Multiple pump housing

    DOEpatents

    Donoho, II, Michael R.; Elliott; Christopher M.

    2010-03-23

    A fluid delivery system includes a first pump having a first drive assembly, a second pump having a second drive assembly, and a pump housing. At least a portion of each of the first and second pumps are located in the housing.

  1. Winding for linear pump

    DOEpatents

    Kliman, G.B.; Brynsvold, G.V.; Jahns, T.M.

    1989-08-22

    A winding and method of winding for a submersible linear pump for pumping liquid sodium are disclosed. The pump includes a stator having a central cylindrical duct preferably vertically aligned. The central vertical duct is surrounded by a system of coils in slots. These slots are interleaved with magnetic flux conducting elements, these magnetic flux conducting elements forming a continuous magnetic field conduction path along the stator. The central duct has placed therein a cylindrical magnetic conducting core, this core having a cylindrical diameter less than the diameter of the cylindrical duct. The core once placed to the duct defines a cylindrical interstitial pumping volume of the pump. This cylindrical interstitial pumping volume preferably defines an inlet at the bottom of the pump, and an outlet at the top of the pump. Pump operation occurs by static windings in the outer stator sequentially conveying toroidal fields from the pump inlet at the bottom of the pump to the pump outlet at the top of the pump. The winding apparatus and method of winding disclosed uses multiple slots per pole per phase with parallel winding legs on each phase equal to or less than the number of slots per pole per phase. The slot sequence per pole per phase is chosen to equalize the variations in flux density of the pump sodium as it passes into the pump at the pump inlet with little or no flux and acquires magnetic flux in passage through the pump to the pump outlet. 4 figs.

  2. Winding for linear pump

    DOEpatents

    Kliman, Gerald B.; Brynsvold, Glen V.; Jahns, Thomas M.

    1989-01-01

    A winding and method of winding for a submersible linear pump for pumping liquid sodium is disclosed. The pump includes a stator having a central cylindrical duct preferably vertically aligned. The central vertical duct is surrounded by a system of coils in slots. These slots are interleaved with magnetic flux conducting elements, these magnetic flux conducting elements forming a continuous magnetic field conduction path along the stator. The central duct has placed therein a cylindrical magnetic conducting core, this core having a cylindrical diameter less than the diameter of the cylindrical duct. The core once placed to the duct defines a cylindrical interstitial pumping volume of the pump. This cylindrical interstitial pumping volume preferably defines an inlet at the bottom of the pump, and an outlet at the top of the pump. Pump operation occurs by static windings in the outer stator sequentially conveying toroidal fields from the pump inlet at the bottom of the pump to the pump outlet at the top of the pump. The winding apparatus and method of winding disclosed uses multiple slots per pole per phase with parallel winding legs on each phase equal to or less than the number of slots per pole per phase. The slot sequence per pole per phase is chosen to equalize the variations in flux density of the pump sodium as it passes into the pump at the pump inlet with little or no flux and acquires magnetic flux in passage through the pump to the pump outlet.

  3. Recovery after abdominal wall reconstruction.

    PubMed

    Jensen, Kristian Kiim

    2017-03-01

    Incisional hernia is a common long-term complication to abdominal surgery, occurring in more than 20% of all patients. Some of these hernias become giant and affect patients in several ways. This patient group often experiences pain, decreased perceived body image, and loss of physical function, which results in a need for surgical repair of the giant hernia, known as abdominal wall reconstruction. In the current thesis, patients with a giant hernia were examined to achieve a better understanding of their physical and psychological function before and after abdominal wall reconstruction. Study I was a systematic review of the existing standardized methods for assessing quality of life after incisional hernia repair. After a systematic search in the electronic databases Embase and PubMed, a total of 26 studies using standardized measures for assessment of quality of life after incisional hernia repair were found. The most commonly used questionnaire was the generic Short-Form 36, which assesses overall health-related quality of life, addressing both physical and mental health. The second-most common questionnaire was the Carolinas Comfort Scale, which is a disease specific questionnaire addressing pain, movement limitation and mesh sensation in relation to a current or previous hernia. In total, eight different questionnaires were used at varying time points in the 26 studies. In conclusion, standardization of timing and method of quality of life assessment after incisional hernia repair was lacking. Study II was a case-control study of the effects of an enhanced recovery after surgery pathway for patients undergoing abdominal wall reconstruction for a giant hernia. Sixteen consecutive patients were included prospectively after the implementation of a new enhanced recovery after surgery pathway at the Digestive Disease Center, Bispebjerg Hospital, and compared to a control group of 16 patients included retrospectively in the period immediately prior to the

  4. A pacemaker powered by an implantable biofuel cell operating under conditions mimicking the human blood circulatory system--battery not included.

    PubMed

    Southcott, Mark; MacVittie, Kevin; Halámek, Jan; Halámková, Lenka; Jemison, William D; Lobel, Robert; Katz, Evgeny

    2013-05-07

    Biocatalytic electrodes made of buckypaper were modified with PQQ-dependent glucose dehydrogenase on the anode and with laccase on the cathode and were assembled in a flow biofuel cell filled with serum solution mimicking the human blood circulatory system. The biofuel cell generated an open circuitry voltage, Voc, of ca. 470 mV and a short circuitry current, Isc, of ca. 5 mA (a current density of 0.83 mA cm(-2)). The power generated by the implantable biofuel cell was used to activate a pacemaker connected to the cell via a charge pump and a DC-DC converter interface circuit to adjust the voltage produced by the biofuel cell to the value required by the pacemaker. The voltage-current dependencies were analyzed for the biofuel cell connected to an Ohmic load and to the electronic loads composed of the interface circuit, or the power converter, and the pacemaker to study their operation. The correct pacemaker operation was confirmed using a medical device - an implantable loop recorder. Sustainable operation of the pacemaker was achieved with the system closely mimicking human physiological conditions using a single biofuel cell. This first demonstration of the pacemaker activated by the physiologically produced electrical energy shows promise for future electronic implantable medical devices powered by electricity harvested from the human body.

  5. 5. Station Unwatering Pumps and Sump Pump for Units 1 ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. Station Unwatering Pumps and Sump Pump for Units 1 and 2, view to the west. The unwatering pumps are the two larger items toward the right side of the photograph (one in foreground and one in background. The smaller item toward the left of the photograph is the sump pump. These pumps are used for draining water from the draft chest for maintenance. - Washington Water Power Clark Fork River Cabinet Gorge Hydroelectric Development, Powerhouse, North Bank of Clark Fork River at Cabinet Gorge, Cabinet, Bonner County, ID

  6. A new blood pump for cardiopulmonary bypass: the HiFlow centrifugal pump.

    PubMed

    Göbel, C; Eilers, R; Reul, H; Schwindke, P; Jörger, M; Rau, G

    1997-07-01

    Centrifugal blood pumps are considered to be generally superior to the traditionally used roller pumps in cardiopulmonary bypass. In our institute a new lightweight centrifugal sealless blood pump with a unique spherical thrust bearing and with a magnetic coupling was developed, the HiFlow. The small design makes the pump suitable for applications in complex devices or close to a patient. Hemolysis tests were carried out in which the BioMedicus pump BP-80 and a roller pump were used as reference. The centrifugal pump HiFlow showed the least blood trauma within the group of investigated pumps. In summary, the HiFlow pump concept with its low priming volume and limited contact surfaces shows great potential for clinical applications in cardiopulmonary bypass. Also, the possibility of using the pump as a short-term assist device with an option of a pulsatile driving mode was demonstrated.

  7. Abdominal shotgun trauma: A case report

    PubMed Central

    Toutouzas, Konstantinos G; Larentzakis, Andreas; Drimousis, Panagiotis; Riga, Maria; Theodorou, Dimitrios; Katsaragakis, Stylianos

    2008-01-01

    Introduction One of the most lethal mechanisms of injury is shotgun wound and particularly the abdominal one. Case presentation We report a case of a 45 years old male suffering abdominal shotgun trauma, who survived his injuries. Conclusion The management of the abdominal shotgun wounds is mainly dependent on clinical examination and clinical judgment, while requires advanced surgical skills. PMID:18625076

  8. Abdominal cocoon secondary to disseminated tuberculosis.

    PubMed

    Puppala, Radha; Sripathi, Smiti; Kadavigere, Rajagopal; Koteshwar, Prakashini; Singh, Jyoti

    2014-09-19

    Abdominal cocoon, also known as sclerosing encapsulating peritonitis, represents a rare entity where a variable length of the small bowel is enveloped by a fibrocollagenous membrane giving the appearance of a cocoon. It may be asymptomatic and is often diagnosed incidentally at laparotomy. We present a rare case of abdominal cocoon due to abdominal tuberculosis. 2014 BMJ Publishing Group Ltd.

  9. Evaluation of the Coreless Linear Conduction Pump for Thermoelectromagnetic Pumps,

    DTIC Science & Technology

    1991-08-01

    Accession Number: 4466 Publication Date: Aug 01, 1991 Title: Evaluation of the Coreless Linear Conduction Pump for Thermoelectromagnetic Pumps ...083191 Report Prepared for: SDIO/T/SL, Washington, DC 20301-7100 Descriptors, Keywords: Coreless Linear Conduction Pump Thermoelectromagnetic...000001 Record ID: 26727 SUMMARY The purpose of the Coreless Linear Conduction Pump (CLCP) was to evaluate the feasibility of the CLCP as a means of

  10. Sensitivity Analysis of Median Lifetime on Radiation Risks Estimates for Cancer and Circulatory Disease amongst Never-Smokers

    NASA Technical Reports Server (NTRS)

    Chappell, Lori J.; Cucinotta, Francis A.

    2011-01-01

    Radiation risks are estimated in a competing risk formalism where age or time after exposure estimates of increased risks for cancer and circulatory diseases are folded with a probability to survive to a given age. The survival function, also called the life-table, changes with calendar year, gender, smoking status and other demographic variables. An outstanding problem in risk estimation is the method of risk transfer between exposed populations and a second population where risks are to be estimated. Approaches used to transfer risks are based on: 1) Multiplicative risk transfer models -proportional to background disease rates. 2) Additive risk transfer model -risks independent of background rates. In addition, a Mixture model is often considered where the multiplicative and additive transfer assumptions are given weighted contributions. We studied the influence of the survival probability on the risk of exposure induced cancer and circulatory disease morbidity and mortality in the Multiplicative transfer model and the Mixture model. Risks for never-smokers (NS) compared to the average U.S. population are estimated to be reduced between 30% and 60% dependent on model assumptions. Lung cancer is the major contributor to the reduction for NS, with additional contributions from circulatory diseases and cancers of the stomach, liver, bladder, oral cavity, esophagus, colon, a portion of the solid cancer remainder, and leukemia. Greater improvements in risk estimates for NS s are possible, and would be dependent on improved understanding of risk transfer models, and elucidating the role of space radiation on the various stages of disease formation (e.g. initiation, promotion, and progression).

  11. Atmospheric pressure fluctuations in the far infrasound range and emergency transport events coded as circulatory system diseases.

    PubMed

    Didyk, L A; Gorgo, Yu P; Dirckx, J J J; Bogdanov, V B; Buytaert, J A N; Lysenko, V A; Didyk, N P; Vershygora, A V; Erygina, V T

    2008-09-01

    This study examines whether a relation exists between rapid atmospheric pressure fluctuations, attributed to the far infrasound frequency range (APF), and a number of emergency transport events coded as circulatory system diseases (EEC). Over an entire year, the average integral amplitudes of APF in the range of periods from 3 s to 120 s over each hour (HA) were measured. Daily dynamics of HA averaged over the year revealed a wave shape with smooth increase from night to day followed by decrease from day to night. The total daily number of EEC within the city of Kiev, Ukraine, was related to the daily mean of HA (DHA) and to the ratio of HA averaged over the day time to HA averaged over the night time (Rdn), and was checked for confounding effects of classical meteorological variables through non-parametric regression algorithms. The number of EEC were significantly higher on days with high DHA (3.72-11.07 Pa, n = 87) compared to the low DHA (0.7-3.62 Pa, n = 260, p = 0.01), as well at days with low Rdn (0.21-1.64, n = 229) compared to the high Rdn (1.65-7.2, n = 118, p = 0.03). A difference between DHA and Rdn effects on the emergency events related to different categories of circulatory diseases points to a higher sensitivity of rheumatic and cerebro-vascular diseases to DHA, and ischaemic and hypertensive diseases to Rdn. Results suggest that APF could be considered as a meteorotropic factor capable of influencing circulatory system diseases.

  12. Atmospheric pressure fluctuations in the far infrasound range and emergency transport events coded as circulatory system diseases

    NASA Astrophysics Data System (ADS)

    Didyk, L. A.; Gorgo, Yu. P.; Dirckx, J. J. J.; Bogdanov, V. B.; Buytaert, J. A. N.; Lysenko, V. A.; Didyk, N. P.; Vershygora, A. V.; Erygina, V. T.

    2008-09-01

    This study examines whether a relation exists between rapid atmospheric pressure fluctuations, attributed to the far infrasound frequency range (APF), and a number of emergency transport events coded as circulatory system diseases (EEC). Over an entire year, the average integral amplitudes of APF in the range of periods from 3 s to 120 s over each hour (HA) were measured. Daily dynamics of HA averaged over the year revealed a wave shape with smooth increase from night to day followed by decrease from day to night. The total daily number of EEC within the city of Kiev, Ukraine, was related to the daily mean of HA (DHA) and to the ratio of HA averaged over the day time to HA averaged over the night time (Rdn), and was checked for confounding effects of classical meteorological variables through non-parametric regression algorithms. The number of EEC were significantly higher on days with high DHA (3.72 11.07 Pa, n = 87) compared to the low DHA (0.7 3.62 Pa, n = 260, p = 0.01), as well at days with low Rdn (0.21 1.64, n = 229) compared to the high Rdn (1.65 7.2, n = 118, p = 0.03). A difference between DHA and Rdn effects on the emergency events related to different categories of circulatory diseases points to a higher sensitivity of rheumatic and cerebro-vascular diseases to DHA, and ischaemic and hypertensive diseases to Rdn. Results suggest that APF could be considered as a meteorotropic factor capable of influencing circulatory system diseases.

  13. A painful pulsatile abdominal mass in a young man with elevated blood pressures: an unusual presentation of phaeochromocytoma.

    PubMed

    Lee, B M K; Ti, L K

    2002-08-01

    We report an unusual presentation of phaeochromocytoma in a young man with a painful, pulsatile abdominal mass and elevated blood pressures. This led to a delay in diagnosis and resulted in the administration of triggers of catecholamine release, possibly causing a catecholamine surge. This caused the development of catecholamine-induced cardiomyopathy and multiple organ failure, requiring inotropic and ventilatory support, intra-aortic balloon pump and dialysis. Fortunately, his condition reversed with supportive treatment and alpha-adrenergic blockade. This illustrates the importance of having a high index of suspicion of phaeochromocytoma, especially in young patients with elevated blood pressures.

  14. Circulatory Estrogen Level Protects Against Breast Cancer in Obese Women

    PubMed Central

    Suba, Zsuzsanna

    2013-01-01

    Literary data suggest apparently ambiguous interaction between menopausal status and obesity-associated breast cancer risk based on the principle of the carcinogenic capacity of estrogen. Before menopause, breast cancer incidence is relatively low and adiposity is erroneously regarded as a protective factor against this tumor conferred by the obesity associated defective estrogen-synthesis. By contrast, in postmenopausal cases, obesity presents a strong risk factor for breast cancer being mistakenly attributed to the presumed excessive estrogen-production of their adipose-tissue mass. Obesity is associated with dysmetabolism and endangers the healthy equilibrium of sexual hormone-production and regular menstrual cycles in women, which are the prerequisites not only for reproductive capacity but also for somatic health. At the same time, literary data support that anovulatory infertility is a very strong risk for breast cancer in young women either with or without obesity. In the majority of premenopausal women, obesity associated insulin resistance is moderate and may be counteracted by their preserved circulatory estrogen level. Consequently, it is not obesity but rather the still sufficient estrogen-level, which may be protective against breast cancer in young adult females. In obese older women, never using hormone replacement therapy (HRT) the breast cancer risk is high, which is associated with their continuous estrogen loss and increasing insulin-resistance. By contrast, obese postmenopausal women using HRT, have a decreased risk for breast cancer as the protective effect of estrogen-substitution may counteract to their obesity associated systemic alterations. The revealed inverse correlation between circulatory estrogen-level and breast cancer risk in obese women should advance our understanding of breast cancer etiology and promotes primary prevention measures. New patents recommend various methods for the prevention and treatment of obesity

  15. Abdominal compartment syndrome related to noninvasive ventilation.

    PubMed

    De Keulenaer, Bart L; De Backer, Adelard; Schepens, Dirk R; Daelemans, Ronny; Wilmer, Alexander; Malbrain, Manu L N G

    2003-07-01

    To study the effects of noninvasive positive pressure ventilation (NIPPV) on intra-abdominal pressure. Single case report from a tertiary teaching hospital. A 65-year-old man who experienced a sudden respiratory and cardiovascular collapse during NIPPV. This was caused by gastric overdistension due to aerophagia followed by raised intra-abdominal pressure leading to intra-abdominal hypertension and abdominal compartment syndrome. The respiratory and cardiovascular problems resolved immediately after the introduction of a nasogastric tube. This resulted in normalization of IAP. This is the first case reported of an abdominal compartment syndrome related to NIPPV. Clinicians should be aware of this possible complication while using NIPPV.

  16. Quantification of fetal and total circulatory DNA in maternal plasma samples before and after size fractionation by agarose gel electrophoresis.

    PubMed

    Hromadnikova, I; Zejskova, L; Doucha, J; Codl, D

    2006-11-01

    Fetal extracellular DNA is mainly derived from apoptotic bodies of trophoblast. Recent studies have shown size differences between fetal and maternal extracellular DNA. We have examined the quantification of fetal (SRY gene) and total (GLO gene) extracellular DNA in maternal plasma in different fractions (100-300, 300-500, 500-700, 700-900, and >900 bp) after size fractionation by agarose gel electrophoresis. DNA was extracted from maternal plasma samples from 11 pregnant women carrying male foetuses at the 16th week of gestation. Fetal circulatory DNA was mainly detected in the 100-300 bp fraction with the median concentration being 14.4 GE/ml. A lower median amount of 4.9 GE/ml was also found in the 300-500 bp fraction. Circulatory DNA extracted from the 100-300 bp fraction contained 4.2 times enriched fetal DNA when compared with unseparated DNA sample. Fetal DNA within the 300-500 bp fraction was 2.5 times enriched. Circulatory fetal DNA is predominantly present in a fraction with molecular size <500 bp, which can be used for the detection of paternally inherited alleles. However, the usage of size-separated DNA is not suitable for routine clinical applications because of risk of contamination.

  17. CIRCULATORY FAILURE DURING NON-INHALED FORMS OF CYANIDE INTOXICATION

    PubMed Central

    Haouzi, Philippe; Tubbs, Nicole; Rannals, Matthew D.; Judenherc-Haouzi, Annick; Cabell, Larry A.; McDonough, Joe A.; Sonobe, Takashi

    2016-01-01

    Our objective was to determine how circulatory failure develops following systemic administration of potassium cyanide (KCN). We used a non-inhaled modality of intoxication, wherein the change in breathing pattern would not influence the diffusion of CN into the blood, akin to the effects of ingesting toxic levels of CN. In a group of 300–400 g rats, CN-induced coma (CN IP, 7 mg/kg) produced a central apnea within 2–3 minutes along with a potent and prolonged gasping pattern leading to auto-resuscitation in 38% of the animals. Motor deficits and neuronal necrosis were nevertheless observed in the surviving animals. To clarify the mechanisms leading to potential auto-resuscitation versus asystole, 12 urethane-anesthetized rats were then exposed to the lowest possible levels of CN exposure that would lead to breathing depression within 7–8 minutes; this dose averaged 0.375 mg/kg/min iv. At this level of intoxication, a cardiac depression developed several minutes only after the onset of the apnea, leading to cardiac asystole as PaO2 reached value around 15 Torr, unless breathing was maintained by mechanical ventilation or through spontaneous gasping. Higher levels of KCN exposure in 10 animals provoked a primary cardiac depression, which led to a rapid cardiac arrest by pulseless electrical activity despite the maintenance of PaO2 by mechanical ventilation. These effects were totally unrelated to the potassium contained in KCN. It is concluded that circulatory failure can develop as a direct consequence of CN induced apnea but in a narrow range of exposure. In this “low” range, maintaining pulmonary gas exchange after exposure, through mechanical ventilation (or spontaneous gasping) can reverse cardiac depression and restore spontaneous breathing. At higher level of intoxication, cardiac depression is to be treated as a specific and spontaneously irreversible consequence of CN exposure, leading to a pulseless electrical activity. PMID:27513083

  18. 32. PLAN OF DEER ISLAND PUMPING STATION SHOWING EXISTING PUMPING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    32. PLAN OF DEER ISLAND PUMPING STATION SHOWING EXISTING PUMPING PLANT AND LOCATION OF PROPOSED ADDITIONS, JULY 1898 SHEET NO. 1. Aperture card 4966-1 - Deer Island Pumping Station, Boston, Suffolk County, MA

  19. The utility of focused abdominal ultrasound in blunt abdominal trauma: a reappraisal.

    PubMed

    Helling, Thomas S; Wilson, Jennifer; Augustosky, Kim

    2007-12-01

    Focused assessment with sonography for trauma (FAST) has become commonplace in the management of blunt abdominal trauma. However, newer computed tomography (CT) scanners have decreased imaging time for trauma patients and provide more detailed examination of abdominal contents. It was the aim of the current study to evaluate practice patterns of FAST and abdominal CT in blunt trauma victims. This was a retrospective study of all blunt trauma patients (N = 299) who received at least 1 FAST examination in the emergency department by surgeons and were admitted. Patients were tracked for subsequent CT scanning, disposition from the emergency department, any operative findings, and survival. Twenty-one of 299 patients (7%) had a positive FAST. There were 7 deaths and 14 patients were taken directly to the operating room (OR) for control of abdominal bleeding. Thirty-one of 299 (10%) had equivocal FAST. There were 4 deaths and 8 patients were taken to the OR for control of abdominal bleeding. A total of 247 of the 299 patients had a negative FAST. CT scans were performed in 193: 15 showed a visceral injury. There were 13 deaths and 29 patients were taken to the OR (4 for bleeding). Patients with a positive FAST had a higher mortality than FAST-negative patients (P < .001) and greater likelihood for operation (P < .001). Those with equivocal FAST had a greater likelihood for operation than FAST-negative patients (P < .05). FAST examinations can identify patients at risk for hemorrhage and in whom operation may be needed and, therefore, can guide mobilization of hospital resources. FAST-negative patients can be managed expectantly, using more specific imaging techniques.

  20. Effect of abdominal negative-pressure wound therapy on the measurement of intra-abdominal pressure.

    PubMed

    García, Alberto Federico; Sánchez, Álvaro Ignacio; Gutiérrez, Álvaro José; Bayona, Juan Gabriel; Naranjo, María Paula; Lago, Sebastián; Puyana, Juan Carlos

    2018-07-01

    In critically ill surgical patients undergoing abdominal negative-pressure wound therapy (NPWT), it remains uncertain whether or not intra-abdominal pressure (IAP) measurements should be obtained when NPWT is activated. We aimed to determine agreement between IAP measured with and without NPWT. In this analytic cross-sectional study, critically ill surgical adults (≥18 y) requiring abdominal NPWT for temporary abdominal closure after a damage control laparotomy were selected. Patients with urinary tract injuries or with pelvic packing were excluded. Paired IAP measures were performed in the same patient, with and without NPWT; two different operators performed the measures unaware of the other's result. Bland-Altman methods assessed the agreement between the two measures. Subgroup analyses (trauma and nontrauma) were performed. There were 198 IAP measures (99 pairs) in 38 patients. Mean IAP with and without NPWT were 8.33 (standard deviation 4.01) and 8.65 (standard deviation 4.04), respectively. Mean IAP difference was -0.323 (95% confidence interval -0.748 to 0.101), and reference range for difference was -4.579 to 3.932 (P = 0.864). From 112 IAP measures (56 pairs) in 21 trauma patients, mean IAP difference was -0.268 (95% confidence interval -0.867 to 0.331), and reference range for the difference was -4.740 to 4.204 (P = 0.427). There was no statistically significant disagreement in IAP measures. IAP could be measured with or without NPWT. In critically ill surgical patients with abdominal NPWT for temporary abdominal closure, monitoring and management of IAP either with or without NPWT is recommended. Copyright © 2018 Elsevier Inc. All rights reserved.

  1. Chemical pump study

    NASA Technical Reports Server (NTRS)

    Bergquist, L. E.

    1973-01-01

    Sorption pumps applicable to the Pioneer Venus Mass Spectrometer Experiment were investigated. The pump requirements are discussed, and a survey of the existing pumps presented. Zirconium and zirconium graphite products were found to be the most promising among the getter materials surveyed. A preliminary pump design for the noble gas experiment is discussed.

  2. Why are patients prescribed proton pump inhibitors? Retrospective analysis of link between morbidity and prescribing in the General Practice Research Database

    PubMed Central

    Bashford, James N R; Norwood, Jeff; Chapman, Stephen R

    1998-01-01

    Objectives: To establish the relation between new prescriptions for proton pump inhibitors and recorded upper gastrointestinal morbidity within a large computerised general practitioner database. Design: Retrospective survey of morbidity and prescribing data linked to new prescriptions for proton pump inhibitors and comparison with licensed indications between 1991 and 1995. Setting: General Practice Research Database and prescribing analysis and cost (PACT) data for the former West Midlands region. Subjects: Information for 612 700 patients in the General Practice Research Database. Anonymous PACT data for all general practitioners in West Midlands region. Main outcome measures: Diagnostic codes linked to the first prescriptions issued for proton pump inhibitors; relation between new prescriptions and licensed indications; yearly change in ratio of new to repeat prescriptions and prescribing volumes measured as defined daily doses. Results: Oesophagitis was the commonest recorded indication in 1991, accounting for 31% of new prescriptions, but was third in 1995 (14%). During the study new prescriptions increased substantially, especially for duodenal disease (780%) and non-ulcer dyspepsia (690%). In 1995 non-specific morbidity accounted for 46% of new prescriptions. The total volume of prescribing rose 10-fold between 1991 and 1995, when repeat prescribing accounted for 77% of the total. Conclusions: Changes in recorded morbidity associated with new prescriptions of proton pump inhibitors did not necessarily reflect changes in licensed indications. Although general practitioners seemed to respond to changes in licensing, particularly for duodenal and gastric disease, prescribing for unlicensed indications non-ulcer dyspepsia and non-specific abdominal pain increased. Key messages There has been much speculation about the reasons behind the substantial rise in prescribing of proton pump inhibitors, especially their use for minor symptoms. We used the General

  3. 33. PLAN OF DEER ISLAND PUMPING STATION SHOWING EXISTING PUMPING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    33. PLAN OF DEER ISLAND PUMPING STATION SHOWING EXISTING PUMPING PLAN AND LOCATION OF PROPOSED ADDITIONS, METROPOLITAN WATER AND SEWERAGE BOARD, METROPOLITAN SEWERAGE WORKS, JULY 1908. Aperture card 6417. - Deer Island Pumping Station, Boston, Suffolk County, MA

  4. Intra-abdominal pressure: an integrative review

    PubMed Central

    Milanesi, Rafaela; Caregnato, Rita Catalina Aquino

    2016-01-01

    ABSTRACT There is a growing request for measuring intra-abdominal pressure in critically ill patients with acute abdominal pain to be clarified. Summarizing the research results on measurement of vesical intra-abdominal pressure and analyzing the level of evidence were the purposes of this integrative literature review, carried out based on the databases LILACS, MEDLINE and PubMed, from 2005 to July 2012. Twenty articles were identified, in that, 12 literature reviews, 4 descriptive and exploratory studies, 2 expert opinions, one prospective cohort study and one was an experience report. The vesical intra-abdominal pressure measurement was considered gold standard. There are variations in the technique however, but some common points were identified: complete supine position, in absence of abdominal contracture, in the end of expiration and expressed in mmHg. Most research results indicate keeping the transducer zeroed at the level of the mid-axillary line at the iliac crest level, and instill 25mL of sterile saline. Strong evidence must be developed. PMID:26958978

  5. Axial Pump

    NASA Technical Reports Server (NTRS)

    Bozeman, Richard J., Jr. (Inventor); Akkerman, James W. (Inventor); Aber, Gregory S. (Inventor); VanDamm, George Arthur (Inventor); Bacak, James W. (Inventor); Svejkovsky, Paul A. (Inventor); Benkowski, Robert J. (Inventor)

    1997-01-01

    A rotary blood pump includes a pump housing for receiving a flow straightener, a rotor mounted on rotor bearings and having an inducer portion and an impeller portion, and a diffuser. The entrance angle, outlet angle, axial and radial clearances of blades associated with the flow straightener, inducer portion, impeller portion and diffuser are optimized to minimize hemolysis while maintaining pump efficiency. The rotor bearing includes a bearing chamber that is filled with cross-linked blood or other bio-compatible material. A back emf integrated circuit regulates rotor operation and a microcomputer may be used to control one or more back emf integrated circuits. A plurality of magnets are disposed in each of a plurality of impeller blades with a small air gap. A stator may be axially adjusted on the pump housing to absorb bearing load and maximize pump efficiency.

  6. Intestinal injury mechanisms after blunt abdominal impact.

    PubMed

    Cripps, N P; Cooper, G J

    1997-03-01

    Intestinal injury is frequent after non-penetrating abdominal trauma, particularly after modern, high-energy transfer impacts. Under these circumstances, delay in the diagnosis of perforation is a major contributor to morbidity and mortality. This study establishes patterns of intestinal injury after blunt trauma by non-penetrating projectiles and examines relationships between injury distribution and abdominal wall motion. Projectile impacts of variable momentum were produced in 31 anaesthetised pigs to cause abdominal wall motion of varying magnitude and velocity. No small bowel injury was observed at initial impact velocity of less than 40 m/s despite gross abdominal compression. At higher velocity, injury to the small bowel was frequent, irrespective of the degree of abdominal compression (P = 0.00044). Large bowel injury was observed at all impact velocities and at all degrees of abdominal compression. This study confirms the potential for intestinal injury in high velocity, low momentum impacts which do not greatly compress the abdominal cavity and demonstrates apparent differences in injury mechanisms for the small bowel and colon. Familiarity with injury mechanisms may reduce delays in the diagnosis of intestinal perforation in both military and civilian situations.

  7. A Newborn With Abdominal Pain.

    PubMed

    Alwan, Riham; Drake, Meredith; Gurria Juarez, Juan; Emery, Kathleen H; Shaaban, Aimen F; Szabo, Sara; Sobolewski, Brad

    2017-11-01

    A previously healthy 3-week-old boy presented with 5 hours of marked fussiness, abdominal distention, and poor feeding. He was afebrile and well perfused. His examination was remarkable for localized abdominal tenderness and distention. He was referred to the emergency department in which an abdominal radiograph revealed gaseous distention of the bowel with a paucity of gas in the pelvis. Complete blood cell count and urinalysis were unremarkable. His ongoing fussiness and abnormal physical examination prompted consultation with surgery and radiology. Our combined efforts ultimately established an unexpected diagnosis. Copyright © 2017 by the American Academy of Pediatrics.

  8. Gas pump with movable gas pumping panels

    DOEpatents

    Osher, John E.

    1984-01-01

    Apparatus for pumping gas continuously a plurality of articulated panels of getter material, each of which absorbs gases on one side while another of its sides is simultaneously reactivated in a zone isolated by the panels themselves from a working space being pumped.

  9. Gas pump with movable gas pumping panels

    DOEpatents

    Osher, J.L.

    Apparatus for pumping gas continuously a plurality of articulated panels of getter material, each of which absorbs gases on one side while another of its sides is simultaneously reactivated in a zone isolated by the panels themselves from a working space being pumped.

  10. Acute abdomen in children due to extra-abdominal causes.

    PubMed

    Tsalkidis, Aggelos; Gardikis, Stefanos; Cassimos, Dimitrios; Kambouri, Katerina; Tsalkidou, Evanthia; Deftereos, Savas; Chatzimichael, Athanasios

    2008-06-01

    Acute abdominal pain in children is a common cause for referral to the emergency room and for subsequent hospitalization to pediatric medical or surgical departments. There are rare occasions when the abdominal pain is derived from extra-abdominal organs or systems. The aim of the present study was to establish the most common extra-abdominal causes of acute abdominal pain. The notes of all children (1 month-14 years of age) examined for acute abdominal pain in the Accident and Emergency (A&E) Department of Alexandroupolis District University Hospital in January 2001-December 2005 were analyzed retrospectively. Demographic data, clinical signs and symptoms, and laboratory findings were recorded, as well as the final diagnosis and outcome. Of a total number of 28 124 children who were brought to the A&E department, in 1731 the main complaint was acute abdominal pain. In 51 children their symptoms had an extra-abdominal cause, the most frequent being pneumonia (n = 15), tonsillitis (n = 10), otitis media (n = 9), and acute leukemia (n = 5). Both abdominal and extra-abdominal causes should be considered by a pediatrician who is confronted with a child with acute abdominal pain.

  11. [Clinical Approach to Abdominal Pain as Functional Origin].

    PubMed

    Ryu, Han Seung; Choi, Suck Chei

    2018-02-25

    Abdominal pain is a common symptom that patients refer to a hospital. Organic causes should be differentiated in patients with abdominal pain and treatment should be administered in accordance with the causes. A meticulous history taking and physical examination are highly useful in making a diagnosis, and blood tests, imaging modalities, and endoscopy are useful for confirming diagnosis. However, in many cases, patients have functional disorders with no obvious abnormal findings obtained even if many diagnostic tests are performed. Patients with functional disorders usually complain the vague abdominal pain located in the center and other portions of the abdominal area. Although the most representative disease is irritable bowel syndrome, functional abdominal pain syndrome is currently researched as a new disease entity of functional abdominal pain. As various receptors related to functional abdominal pain have been discovered, drugs associated with those receptors are used to treat the disorders, and additional new drugs are vigorously developed. In addition, medical therapy with pharmacological or non-pharmacological psychiatric treatment is effective for treating functional abdominal pain.

  12. [Indocyanine green infrared fluorescence angiography and vascular cast--preparation in experimental choroidal circulatory disturbance].

    PubMed

    Matsunaga, H; Andoh, A; Matsubara, T; Fukushima, I; Takahashi, K; Ohkuma, H; Uyama, M

    1996-03-01

    We performed experiments in 20 monkey eyes in order to clarify basic problems about interpretation of indocyanine green fluorescence angiography (ICG angiography). We severed the temporal group of posterior ciliary arteries to produce choroidal circulatory disturbance. ICG angiography was performed immediately, and 2 days, 4 days, and 2 weeks later. Following each ICG angiography, the eye was studied by plastic vascular cast technique with scanning electron microscopy. Immediately after occlusion, ICG angiography showed filling defect in the temporal choroidal hemisphere during the early phase. In the later phase, this area was gradually filled by the dye from choroidal arteries in the nasal hemisphere and the anterior ciliary arteries. Vascular cast preparations showed filling defect in the temporal choroidal hemisphere, corresponding with the early ICG angiogaphic findings. Both filling delay in ICG angiography and filling defect in vascular casts improved daily after occlusion. Two weeks after occlusion, The area of choroidal infarct temporal to the macula turned into chorioretinal atrophy. This area showed hypofluorescence in the early-phase ICG angiography and filling defect of the choriocapillaris in plastic casts. The early-phase ICG angiographic findings thus corresponded well with observations of vascular casts. We conclude that ICG angiography correctly reflects the actual circulatory disturbances in the choroid.

  13. [Organ donation after circulatory death].

    PubMed

    de Jonge, J; Kalisvaart, M; van der Hoeven, M; Epker, J; de Haan, J; IJzermans, J N M; Grüne, F

    2016-02-01

    Approximately 17 million inhabitants live in the Netherlands. The number of potential organ donors in 1999 was the lowest in Europe with only 10 donors per million inhabitants. Medical associations, public health services, health insurance companies and the government had to find common solutions in order to improve organ allocation, logistics of donations and to increase the number of transplantations. After a prolonged debate on medical ethical issues of organ transplantation, all participants were able to agree on socio-medico-legal regulations for organ donation and transplantation. In addition to improving the procedure for organ donation after brain death (DBD) the most important step was the introduction of organ donation after circulatory death (DCD). Measures such as the introduction of a national organ donor database, improved information to the public, further education on intensive care units (ICU), guidelines for end of life care on the ICU, establishment of transplantation coordinators on site, introduction of autonomous explantation teams and strict procedures on the course of organ donations, answered many practical issues about logistics and responsibilities for DBD and DCD. In 2014 the number of postmortem organ donations rose to 16.4 per million inhabitants. Meanwhile, up to 60 % of organ donations in the Netherlands originate from a DCD procedure compared to approximately 10 % in the USA. This overview article discusses the developments and processes of deceased donation in the Netherlands after 15 years of experience with DCD.

  14. Outcome of Cardiac Rehabilitation Following Off-Pump Versus On-Pump Coronary Bypass Surgery

    PubMed Central

    Arefizadeh, Reza; Hariri, Seyed Yaser; Moghadam, Adel Johari

    2017-01-01

    BACKGROUND: A few studies have compared the cardiac rehabilitation (CR) outcome between those who undergo conventional on-pump bypass surgery and off-pump surgery. We compared this outcome among the patients differentiated by the On-pump and off-pump surgical procedures about cardiovascular variables and psychological status. METHODS: This longitudinal study recruited 318 and 102 consecutive patients who had undergone CABG (on-pump surgery, n = 318 and off-pump surgery, n = 102) and been referred to the CR clinic. RESULTS: The off-pump surgery patients had more improvement in their metabolic equivalents (METs) value. The physical and mental components of health-related quality of life (QOL) (based on SF-36 questionnaire) as well as depression-anxiety (based on Costello-Comrey Depression and Anxiety Scale) were notably improved in the two study groups after the CR program, while changes in the QOL components scores and also depression-anxiety score were not different between the off-pump and on-pump techniques. CONCLUSIONS: Regarding QOL and psychological status, there were no differences in the CR outcome between those who underwent off-pump bypass surgery and those who underwent on-pump surgery; nevertheless, the off-pump technique was superior to the on-pump method on METs improvement following CR. PMID:28698744

  15. Outcome of Cardiac Rehabilitation Following Off-Pump Versus On-Pump Coronary Bypass Surgery.

    PubMed

    Arefizadeh, Reza; Hariri, Seyed Yaser; Moghadam, Adel Johari

    2017-06-15

    A few studies have compared the cardiac rehabilitation (CR) outcome between those who undergo conventional on-pump bypass surgery and off-pump surgery. We compared this outcome among the patients differentiated by the On-pump and off-pump surgical procedures about cardiovascular variables and psychological status. This longitudinal study recruited 318 and 102 consecutive patients who had undergone CABG (on-pump surgery, n = 318 and off-pump surgery, n = 102) and been referred to the CR clinic. The off-pump surgery patients had more improvement in their metabolic equivalents (METs) value. The physical and mental components of health-related quality of life (QOL) (based on SF-36 questionnaire) as well as depression-anxiety (based on Costello-Comrey Depression and Anxiety Scale) were notably improved in the two study groups after the CR program, while changes in the QOL components scores and also depression-anxiety score were not different between the off-pump and on-pump techniques. Regarding QOL and psychological status, there were no differences in the CR outcome between those who underwent off-pump bypass surgery and those who underwent on-pump surgery; nevertheless, the off-pump technique was superior to the on-pump method on METs improvement following CR.

  16. 39. THREECYLINDER HYDRAULIC OIL PUMP (MANUFACTURED BY WORTHINGTON: PUMP AND ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    39. THREE-CYLINDER HYDRAULIC OIL PUMP (MANUFACTURED BY WORTHINGTON: PUMP AND MACHINERY COMPANY, HOLYOKE MASSACHUSETTS) IN MACHINERY CHAMBER FOR SLUICE GATE WORKS ON GALLERY 1. NOTE OIL TANK ABOVE PUMP MOTOR. VIEW TO NORTHWEST. - Owyhee Dam, Across Owyhee River, Nyssa, Malheur County, OR

  17. Overview of Pump Room, showing pumps at right and power ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Overview of Pump Room, showing pumps at right and power distribution cabinets for valve motors along north wall at left. View to east - Wellton-Mohawk Irrigation System, Pumping Plant No. 1, Bounded by Gila River & Union Pacific Railroad, Wellton, Yuma County, AZ

  18. Novel Method for Exchange of Impella Circulatory Assist Catheter: The "Trojan Horse" Technique.

    PubMed

    Phillips, Colin T; Tamez, Hector; Tu, Thomas M; Yeh, Robert W; Pinto, Duane S

    2017-07-01

    Patients with an indwelling Impella may require escalation of hemodynamic support or exchange to another circulatory assistance platform. As such, preservation of vascular access is preferable in cases where anticoagulation cannot be discontinued or to facilitate exchange to an alternative catheter or closure device. Challenges exist in avoiding bleeding and loss of wire access in these situations. We describe a single-access "Trojan Horse" technique that minimizes bleeding while maintaining arterial access for rapid exchange of this percutaneous ventricular assist device.

  19. Effect of the Prophylactic Use of Proton-Pump Inhibitors on the Pattern of Gastrointestinal Symptoms in Patients Late After Kidney Transplant.

    PubMed

    Królikowski, Jerzy; Pawłowicz, Ewa; Budzisz, Ewa; Nowicki, Michał

    2016-10-01

    Although immunosuppressive drugs have been recognized as leading causes of gastrointestinal symptoms after kidney transplant, other widely used medications such as proton-pump inhibitors recently have been implicated. Our aim was to study the effects of chronic proton-pump inhibitor therapy on gastrointestinal symptoms in clinically stable patients late after kidney transplant. The study comprised 100 kidney transplant recipients (66 men and 34 women, mean age of 49 ± 12 y, mean time after transplant of 56 ± 46 mo). All patients completed the Gastrointestinal Symptoms Rating Scale and the Quality of Life Questionnaire SF-8 surveys. The most commonly reported symptoms included borborygmus (27%), flatulence (23%), abdominal distension (18%), urgent need of defecation (17%), and heartburn, acid reflux, and eructation (13%). Proton-pump inhibitors were chronically used by 50% of patients and sporadically by 33%. Gastrointestinal Symptoms Rating Scale scores were higher in patients who used proton-pump inhibitors (mean score of 7.8 ± 5.5 vs 4.6 ± 3.0; P = .013). Total score of items representing diarrhea in the Gastrointestinal Symptoms Rating Scale (increased passage of stools, loose stools, urgent need of defecation, incomplete evacuation) was higher in patients treated with proton-pump inhibitors than in those not treated (2.3 ± 2.2 vs 1.3 ± 1.9; P = .04). Chronic use of proton-pump inhibitors may increase the prevalence of gastrointestinal symptoms, particularly diarrhea, in patients late after kidney transplant.

  20. DISK PUMP FEASIBILITY INVESTIGATION,

    DTIC Science & Technology

    system as an inducer and/or mainstage pump for liquid rocket applications. This investigation consisted of the analysis, design, and test of a disk...pumping action is a function of the viscous properties of the pumped fluid. (2) The pump does not require the conventional pump lifting forces. ( 3 ...with no apparent head deterioration. The representative maximum suction specific speed at a 3 % head drop was never reached. The pump demonstrated

  1. Students' Visualization of Diagrams Representing the Human Circulatory System: The Use of Spatial Isomorphism and Representational Conventions

    ERIC Educational Resources Information Center

    Cheng, Maurice M. W.; Gilbert, John K.

    2015-01-01

    This study investigated students' interpretation of diagrams representing the human circulatory system. We conducted an interview study with three students aged 14-15 (Year 10) who were studying biology in a Hong Kong school. During the interviews, students were asked to interpret diagrams and relationships between diagrams that represented…

  2. Effect of increasing pump speed during exercise on peak oxygen uptake in heart failure patients supported with a continuous-flow left ventricular assist device. A double-blind randomized study.

    PubMed

    Jung, Mette Holme; Hansen, Peter Bo; Sander, Kaare; Olsen, Peter Skov; Rossing, Kasper; Boesgaard, Soeren; Russell, Stuart D; Gustafsson, Finn

    2014-04-01

    Continuous-flow left ventricular assist device (CF-LVAD) implantation is associated with improved quality of life, but the effect on exercise capacity is less well documented. It is uncertain whether a fixed CF-LVAD pump speed, which allows for sufficient circulatory support at rest, remains adequate during exercise. The aim of this study was to evaluate the effects of fixed versus incremental pump speed on peak oxygen uptake (peak VO2) during a maximal exercise test. In CF-LVAD (HeartMate II) patients exercise testing measuring peak oxygen uptake (VO2) was performed on an ergometer bike twice in one day: once with fixed pump speed (testfix) and once with incremental pump speed (testinc). The order of testfix and testinc in each patient was determined by randomization. During testinc pump speed was increased from the baseline value by 400 rpm/2 min. Fourteen patients (aged 23–69 years) were included with a mean support duration of 465±483 days. Baseline CF-LVAD speed was 9357±238 rpm and during testinc speed was increased by a mean of 1486±775 rpm. Mean peak VO2 was significantly higher in testinc compared with testfix (15.4±5.9 mL/kg/min vs. 14.1±6.3 mL/kg/min; P=0.012), corresponding to a 9.2% increase. All exercise tests (n=28) were adequately performed with RER>1. Increasing pump speed during exercise augments peak VO2 in patients supported with CF-LVADs. An automatic speed-change function in future generations of CF-LVADs might improve functional capacity. © 2014 The Authors. European Journal of Heart Failure © 2014 European Society of Cardiology.

  3. Modeling and control of a brushless DC axial flow ventricular assist device.

    PubMed

    Giridharan, Guruprasad A; Skliar, Mikhail; Olsen, Donald B; Pantalos, George M

    2002-01-01

    This article presents an integrated model of the human circulatory system that incorporates circulatory support by a brushless DC axial flow ventricular assist device (VAD), and a feedback VAD controller designed to maintain physiologically sufficient perfusion. The developed integrated model combines a network type model of the circulatory system with a nonlinear dynamic model of the brushless DC pump We show that maintaining a reference differential pressure between the left ventricle and aorta leads to adequate perfusion for different pathologic cases, ranging from normal heart to left heart asystole, and widely varying physical activity scenarios from rest to exercise.

  4. Champagne Heat Pump

    NASA Technical Reports Server (NTRS)

    Jones, Jack A.

    2004-01-01

    The term champagne heat pump denotes a developmental heat pump that exploits a cycle of absorption and desorption of carbon dioxide in an alcohol or other organic liquid. Whereas most heat pumps in common use in the United States are energized by mechanical compression, the champagne heat pump is energized by heating. The concept of heat pumps based on other absorption cycles energized by heat has been understood for years, but some of these heat pumps are outlawed in many areas because of the potential hazards posed by leakage of working fluids. For example, in the case of the water/ammonia cycle, there are potential hazards of toxicity and flammability. The organic-liquid/carbon dioxide absorption/desorption cycle of the champagne heat pump is similar to the water/ammonia cycle, but carbon dioxide is nontoxic and environmentally benign, and one can choose an alcohol or other organic liquid that is also relatively nontoxic and environmentally benign. Two candidate nonalcohol organic liquids are isobutyl acetate and amyl acetate. Although alcohols and many other organic liquids are flammable, they present little or no flammability hazard in the champagne heat pump because only the nonflammable carbon dioxide component of the refrigerant mixture is circulated to the evaporator and condenser heat exchangers, which are the only components of the heat pump in direct contact with air in habitable spaces.

  5. How I Manage Abdominal Injuries.

    ERIC Educational Resources Information Center

    Haycock, Christine E.

    1986-01-01

    In sports, abdominal injuries occur most frequently in cycling, horseback riding, and skiing. Most involve children, not adults. Any athlete sustaining a severe blow to the abdomen should be examined. Guidelines are provided for recognizing and treating injuries to the abdominal muscles, kidneys, spleen, and liver. (Author/MT)

  6. 24. Pump Room interiordewatering pump motor on upper level. Note ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    24. Pump Room interior-dewatering pump motor on upper level. Note the removable roof hatch (steel frame) directly above motor. Dewatering pumps motor control center at left - Hunters Point Naval Shipyard, Drydock No. 4, East terminus of Palou Avenue, San Francisco, San Francisco County, CA

  7. Temporary closure of the abdominal wall by use of silicone rubber sheets after operative repair of ruptured abdominal aortic aneurysms.

    PubMed

    Akers, D L; Fowl, R J; Kempczinski, R F; Davis, K; Hurst, J M; Uhl, S

    1991-07-01

    Management of patients after operative repair of abdominal aortic aneurysms can be further complicated if primary closure of the abdominal wall cannot be technically accomplished or is associated with profound increases in intraabdominal and peak inspiratory pressures. We recently treated five patients with ruptured abdominal aortic aneurysms and one patient with a ruptured thoracoabdominal aneurysm whose abdominal incisions had to be closed with a Dacron reinforced, silicone sheet. All patients were hemodynamically unstable either at admission to the hospital or became so during operation. Four patients required the insertion of a silicone rubber sheet at the primary operation because of massive retroperitoneal hematoma or edema of the bowel wall or both. Incisions in two patients were closed primarily, but the patients required reexploration and secondary closure with silicone rubber sheets because of the development of marked increases in peak inspiratory pressures, intraabdominal pressures, and decreased urinary output. Four of the six patients subsequently underwent successful removal of the silicone rubber sheets with delayed primary closure of the abdominal wall, and two others died before removal. The patient with the ruptured thoracoabdominal aneurysm died on postoperative day 20 because of pulmonary sepsis but had a healed abdominal incision. The three surviving patients have been discharged. A silicone rubber sheet may be necessary for closure of the abdominal wall after repair of ruptured abdominal aortic aneurysm in patients where primary abdominal wall closure is impossible or where it results in compromise in respiratory or renal function.

  8. Side-pumping combiner for high-power fiber laser based on tandem pumping

    NASA Astrophysics Data System (ADS)

    Gu, Yanran; Lei, Chengmin; Liu, Jun; Li, Ruixian; Liu, Le; Xiao, Hu; Chen, Zilun

    2017-11-01

    We investigate a (2+1)×1 side-pumping combiner numerically and experimentally for high-power fiber laser based on tandem pumping for the first time. The influence of taper ratio and launch mode on the 1018-nm pump coupling efficiency and the leakage power into the coating of the signal fiber (LPC) is analyzed numerically. A side-pumping combiner is developed successfully by tapered-fused splicing technique based on the numerical analysis, consisting of two pump fibers (220/242 μm, NA=0.22) and a signal fiber (40/400 μm, NA=0.06/0.46). The total 1018-nm pump efficiency of the combiner is 98.1%, and the signal light insertion loss is <3%. The results show that, compared with laser diodes pumping, the combiner appears to have a better LPC performance and power handling capability when using 1018-nm fiber as the pump light. Meanwhile, an all-fiber MOPA laser based on tandem pumping with 1080-nm output of 2533 W and the slope efficiency of 82.8% is achieved based on the home-made combiner.

  9. Effect of abdominal resistance exercise on abdominal subcutaneous fat of obese women: a randomized controlled trial using ultrasound imaging assessments.

    PubMed

    Kordi, Ramin; Dehghani, Saeed; Noormohammadpour, Pardis; Rostami, Mohsen; Mansournia, Mohammad Ali

    2015-01-01

    The aim of this study was to compare the effect of diet and an abdominal resistance training program to diet alone on abdominal subcutaneous fat thickness and waist circumference of overweight and obese women. This randomized clinical trial included 40 overweight and obese women randomly divided into 2 groups: diet only and diet combined with 12 weeks of abdominal resistance training. Waist and hip circumferences and abdominal skin folds of the subjects were measured at the beginning and 12 weeks after the interventions. In addition, abdominal subcutaneous fat thickness of the subjects was measured using ultrasonography. Percentage body fat and lean body mass of all the subjects were also measured using a bioelectric impedance device. After 12 weeks of intervention, the weight of participants in both groups decreased; but the difference between the 2 groups was not significant (P = .45). Similarly, other variables including abdominal subcutaneous fat, waist circumference, hip circumference, body mass index, body fat percentage, and skin fold thickness were reduced in both groups; but there were no significant differences between the groups. This study found that abdominal resistance training besides diet did not reduce abdominal subcutaneous fat thickness compared to diet alone in overweight or obese women. Copyright © 2015 National University of Health Sciences. Published by Elsevier Inc. All rights reserved.

  10. Efficiency and threshold pump intensity of CW solar-pumped solid-state lasers

    NASA Technical Reports Server (NTRS)

    Hwang, In H.; Lee, Ja H.

    1991-01-01

    The authors consider the relation between the threshold pumping intensity, the material properties, the resonator parameters, and the ultimate slope efficiencies of various solid-state laser materials for solar pumping. They clarify the relation between the threshold pump intensity and the material parameters and the relation between the ultimate slope efficiency and the laser resonator parameters such that a design criterion for the solar-pumped solid-state laser can be established. Among the laser materials evaluated, alexandrite has the highest slope efficiency of about 12.6 percent; however, it does not seem to be practical for a solar-pumped laser application because of its high threshold pump intensity. Cr:Nd:GSGG is the most promising for solar-pumped lasing. Its threshold pump intensity is about 100 air-mass-zero (AM0) solar constants and its slope efficiency is about 12 percent when thermal deformation is completely prevented.

  11. Traumatic abdominal hernia complicated by necrotizing fasciitis.

    PubMed

    Martínez-Pérez, Aleix; Garrigós-Ortega, Gonzalo; Gómez-Abril, Segundo Ángel; Martí-Martínez, Eva; Torres-Sánchez, Teresa

    2014-11-01

    Necrotizing fasciitis is a critical illness involving skin and soft tissues, which may develop after blunt abdominal trauma causing abdominal wall hernia and representing a great challenge for physicians. A 52-year-old man was brought to the emergency department after a road accident, presenting blunt abdominal trauma with a large non-reducible mass in the lower-right abdomen. A first, CT showed abdominal hernia without signs of complication. Three hours after ICU admission, he developed hemodynamic instability. Therefore, a new CT scan was requested, showing signs of hernia complication. He was moved to the operating room where a complete transversal section of an ileal loop was identified. Five hours after surgery, he presented a new episode of hemodynamic instability with signs of skin and soft tissue infection. Due to the high clinical suspicion of necrotizing fasciitis development, wide debridement was performed. Following traumatic abdominal wall hernia (TAWH), patients can present unsuspected injuries in abdominal organs. Helical CT can be falsely negative in the early moments, leading to misdiagnosis. Necrotizing fasciitis is a potentially fatal infection and, consequently, resuscitation measures, wide-spectrum antibiotics, and early surgical debridement are required. This type of fasciitis can develop after blunt abdominal trauma following wall hernia without skin disruption.

  12. Laparoscopy In Unexplained Abdominal Pain: Surgeon's Perspective.

    PubMed

    Abdullah, Muhammad Tariq; Waqar, Shahzad Hussain; Zahid, Muhammad Abdul

    2016-01-01

    Unexplained abdominal pain is a common but difficult presenting feature faced by the clinicians. Such patients can undergo a number of investigations with failure to reach any diagnosis. The objective of this study was to evaluate the use of laparoscopy in the diagnosis and management of patients with unexplained abdominal pain. This cross-sectional study was conducted at Pakistan Institute of Medical Sciences Islamabad from January 2009 to December 2013. This study included 91 patients of unexplained abdominal pain not diagnosed by routine clinical examination and investigations. These patients were subjected to diagnostic laparoscopy for evaluation of their conditions and to confirm the diagnosis. These patients presented 43% of patients undergoing investigations for abdominal pain. Patients diagnosed with gynaecological problems were excluded to see surgeon's perspective. The findings and the outcomes of the laparoscopy were recorded and data was analyzed. Unexplained abdominal pain is common in females than in males. The most common laparoscopic findings were abdominal tuberculosis followed by appendicitis. Ninety percent patients achieved pain relief after laparoscopic intervention. Laparoscopy is both beneficial and safe in majority of patients with unexplained abdominal pain. General surgeons should acquire training and experience in laparoscopic surgery to provide maximum benefit to these difficult patients.

  13. PUMP SETS NO. 5 AND NO. 4. Each pump set ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    PUMP SETS NO. 5 AND NO. 4. Each pump set consists of a Worthington Pump and a General Electric motor - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Flame Deflector Water System, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  14. Economics of abdominal wall reconstruction.

    PubMed

    Bower, Curtis; Roth, J Scott

    2013-10-01

    The economic aspects of abdominal wall reconstruction are frequently overlooked, although understandings of the financial implications are essential in providing cost-efficient health care. Ventral hernia repairs are frequently performed surgical procedures with significant economic ramifications for employers, insurers, providers, and patients because of the volume of procedures, complication rates, the significant rate of recurrence, and escalating costs. Because biological mesh materials add significant expense to the costs of treating complex abdominal wall hernias, the role of such costly materials needs to be better defined to ensure the most cost-efficient and effective treatments for ventral abdominal wall hernias. Copyright © 2013 Elsevier Inc. All rights reserved.

  15. Narrowband diode laser pump module for pumping alkali vapors.

    PubMed

    Rotondaro, M D; Zhdanov, B V; Shaffer, M K; Knize, R J

    2018-04-16

    We describe a method of line narrowing and frequency-locking a diode laser stack to an alkali atomic line for use as a pump module for Diode Pumped Alkali Lasers. The pump module consists of a 600 W antireflection coated diode laser stack configured to lase using an external cavity. The line narrowing and frequency locking is accomplished by introducing a narrowband polarization filter based on magneto-optical Faraday effect into the external cavity, which selectively transmits only the frequencies that are in resonance with the 6 2 S 1/2 → 6 2 P 3/2 transition of Cs atoms. The resulting pump module has demonstrated that a diode laser stack, which lases with a line width of 3 THz without narrowbanding, can be narrowed to 10 GHz. The line narrowed pump module produced 518 Watts that is 80% of the power generated by the original broadband diode laser stack.

  16. Perforated peptic ulcer associated with abdominal compartment syndrome.

    PubMed

    Lynn, Jiun-Jen; Weng, Yi-Ming; Weng, Chia-Sui

    2008-11-01

    Abdominal compartment syndrome (ACS) is defined as an increased intra-abdominal pressure with adverse physiologic consequences. Abdominal compartment syndrome caused by perforated peptic ulcer is rare owing to early diagnosis and management. Delayed recognition of perforated peptic ulcer with pneumoperitoneum, bowel distension, and decreased abdominal wall compliance can make up a vicious circle and lead to ACS. We report a case of perforated peptic ulcer associated with ACS. A 74-year-old man with old stroke and dementia history was found to have distended abdomen, edema of bilateral legs, and cyanosis. Laboratory tests revealed deterioration of liver and kidney function. Abdominal compartment syndrome was suspected, and image study was arranged to find the cause. The study showed pneumoperitoneum, contrast stasis in heart with decreased caliber of vessels below the abdominal aortic level, and diffuse lymphedema at the abdominal walls. Emergent laparotomy was performed. Perforated peptic ulcer was noted and the gastrorrhaphy was done. The symptoms, and liver and kidney function improved right after emergent operation.

  17. Circadian variation in the circulatory responses to exercise: relevance to the morning peaks in strokes and cardiac events

    PubMed Central

    2009-01-01

    Sudden cardiac and cerebral events are most common in the morning. A fundamental question is whether these events are triggered by the increase in physical activity after waking, and/or a result of circadian variation in the responses of circulatory function to exercise. Although signaling pathways from the master circadian clock in the suprachiasmatic nuclei to sites of circulatory control are not yet understood, it is known that cerebral blood flow, autoregulation and cerebrovascular reactivity to changes in CO2 are impaired in the morning and, therefore, could explain the increased risk of cerebrovascular events. Blood pressure (BP) and the rate pressure product (RPP) show marked ‘morning surges’ when people are studied in free-living conditions, making the rupture of a fragile atherosclerotic plaque and sudden cardiac event more likely. Since cerebral autoregulation is reduced in the morning, this surge in BP may also exacerbate the risk of hemorrhagic and ischemic strokes in the presence of other acute and chronic risk factors. Increased sympathetic activity, decreased endothelial function, and increased platelet aggregability could also be important in explaining the morning peak in cardiac and cerebral events but how these factors respond to exercise at different times of day is unclear. Evidence is emerging that the exercise-related responses of BP and RPP are increased in the morning when prior sleep is controlled. We recommend that such ‘semi-constant routine’ protocols are employed to examine the relative influence of the body clock and exogenous factors on the 24-h variation in other circulatory factors. PMID:19826832

  18. Donation after circulatory death: burying the dead donor rule.

    PubMed

    Rodríguez-Arias, David; Smith, Maxwell J; Lazar, Neil M

    2011-08-01

    Despite continuing controversies regarding the vital status of both brain-dead donors and individuals who undergo donation after circulatory death (DCD), respecting the dead donor rule (DDR) remains the standard moral framework for organ procurement. The DDR increases organ supply without jeopardizing trust in transplantation systems, reassuring society that donors will not experience harm during organ procurement. While the assumption that individuals cannot be harmed once they are dead is reasonable in the case of brain-dead protocols, we argue that the DDR is not an acceptable strategy to protect donors from harm in DCD protocols. We propose a threefold alternative to justify organ procurement practices: (1) ensuring that donors are sufficiently protected from harm; (2) ensuring that they are respected through informed consent; and (3) ensuring that society is fully informed of the inherently debatable nature of any criterion to declare death.

  19. Well-pump alignment system

    DOEpatents

    Drumheller, Douglas S.

    1998-01-01

    An improved well-pump for geothermal wells, an alignment system for a well-pump, and to a method for aligning a rotor and stator within a well-pump, wherein the well-pump has a whistle assembly formed at a bottom portion thereof, such that variations in the frequency of the whistle, indicating misalignment, may be monitored during pumping.

  20. Socio-economic factors, health care consumption and rating of abdominal symptom severity. A report from the abdominal symptom study.

    PubMed

    Agréus, L

    1993-06-01

    A study of the abdominal/gastrointestinal symptom panorama in relation to socio-economic factors and health care consumption in the general population was performed in Osthammar, Sweden. A postal questionnaire was sent to a representative sample of the adult population (n = 1260). The response rate was 87%. The responders with symptoms (52.1%) subjectively rated their illness on visual analogue scales. All responders were classified as asymptomatic or having 'minor' or 'major' abdominal symptoms. Those having dyspepsia, reflux or irritable bowel syndrome were also ranked as 'minors' or 'majors'. The proportion of subjects with abdominal/gastrointestinal complaints decreased with age, mainly due to a decrease of 'major' symptoms. Also, the proportion of complainers increased among the more educated. Those on sick leave and students had more and worse symptoms than the others, despite the former seldom stating abdominal discomfort as the main reason for sick listing. Fifty-five per cent of all persons reporting abdominal/gastrointestinal symptoms had at some time consulted a doctor because of such complaints, the proportion increasing with severity, as did drug consumption and the rate of previous abdominal operations, with appendectomy as an exception. The results show that it is possible to rank the illness along a severity dimension among persons with abdominal/gastrointestinal complaints in epidemiological research.

  1. Arterial wall histology in chronic pulsatile-flow and continuous-flow device circulatory support.

    PubMed

    Potapov, Evgenij V; Dranishnikov, Nikolay; Morawietz, Lars; Stepanenko, Alexander; Rezai, Sajjad; Blechschmidt, Cristiane; Lehmkuhl, Hans B; Weng, Yuguo; Pasic, Miralem; Hübler, Michael; Hetzer, Roland; Krabatsch, Thomas

    2012-11-01

    Continuous-flow (CF) ventricular assist devices (VAD) are an established option for treatment of end-stage heart failure. However, the effect of long-term CF with lack of peripheral arterial wall motions on blood pressure regulation and end-organ arterial wall sclerosis, especially in the case of long-term support (> 3 years), remains unclear. Tissue samples obtained at autopsy from liver, kidney, coronary arteries, and brain from 27 VAD recipients supported for > 180 days between 2000 and 2010 were histologically examined to assess vascular alterations, including perivascular infiltrate, intravascular infiltrate, wall thickness, thrombosis, endothelial cell swelling, vessel wall necrosis, and peri-vascular fibrosis. Pulsatile-flow (PF) devices had been inserted in 9 patients and CF devices had been inserted in 16. The pathologist was blinded to the group distribution. Demographic, pharmacologic, and clinical data were retrospectively analyzed before surgery and during the follow-up period of up to 24 months. Median duration of support was 467 days (range, 235-1,588 days) in the PF group and 263 days (range, 182-942 days) in the CF group. Demographic and clinical data before and after surgery were similar. Amiodarone was more often used during follow-up in CF group than in the PF group (61% vs 10%, p = 0.009). Throughout the follow-up period, mean arterial pressure did not differ between recipients of the 2 pump types, nor did systolic and diastolic pressure, except at 2 weeks after VAD implantation, when systolic blood pressure was higher (p = 0.05) and diastolic lower (p = 0.03) in the PF group. Histologic studies did not identify any relevant differences in arterial wall characteristics between the 2 groups. Long-term mechanical circulatory support with CF devices does not adversely influence arterial wall properties of the end-organ vasculature. Copyright © 2012 International Society for Heart and Lung Transplantation. Published by Elsevier Inc. All rights

  2. Electroosmotic pump unit and assembly

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Shaorong

    An electroosmotic pump unit includes at least a first pump element, at least a second pump element, and an electrode. Each pump element includes a tube, an electrically grounded fluid inlet, a fluid outlet electrically coupled to the electrode, and a porous monolith immobilized in the tube and having open pores having net surface charges. When the electrode applies a voltage across the monoliths, a fluid supplied to the first pump element flows through the pump elements in a direction from a fluid inlet of the first pump element toward a fluid outlet of the second pump element. A pluralitymore » of electroosmotic pump units may be connected in series in a pump assembly. The electroosmotic pump unit, or pump assembly, may be connected to an apparatus such as a HPLC.« less

  3. [Internationalization and innovation of abdominal acupuncture].

    PubMed

    Wang, Yong-Zhou

    2013-09-01

    Characteristics of abdominal acupuncture are analyzed through three aspects of inheriting and innovation, collaborated research as well as international visual field. It is pointed that abdominal acupuncture is based on clinical practice, focuses on enhancing the therapeutic effect and expending the clinical application. It also promots the thinking on how to recall the tradition and how to inherit tradition availably. The modern medical problems should be studied and innovation resolutions should be searched, which can help the internationalization and modernization of abdominal acupuncture.

  4. Elasticity of the living abdominal wall in laparoscopic surgery.

    PubMed

    Song, Chengli; Alijani, Afshin; Frank, Tim; Hanna, George; Cuschieri, Alfred

    2006-01-01

    Laparoscopic surgery requires inflation of the abdominal cavity and this offers a unique opportunity to measure the mechanical properties of the living abdominal wall. We used a motion analysis system to study the abdominal wall motion of 18 patients undergoing laparoscopic surgery, and found that the mean Young's modulus was 27.7+/-4.5 and 21.0+/-3.7 kPa for male and female, respectively. During inflation, the abdominal wall changed from a cylinder to a dome shape. The average expansion in the abdominal wall surface was 20%, and a working space of 1.27 x 10(-3)m(3) was created by expansion, reshaping of the abdominal wall and diaphragmatic movement. For the first time, the elasticity of human abdominal wall was obtained from the patients undergoing laparoscopic surgery, and a 3D simulation model of human abdominal wall has been developed to analyse the motion pattern in laparoscopic surgery. Based on this study, a mechanical abdominal wall lift and a surgical simulator for safe/ergonomic port placements are under development.

  5. Well-pump alignment system

    DOEpatents

    Drumheller, D.S.

    1998-10-20

    An improved well-pump for geothermal wells, an alignment system for a well-pump, and to a method for aligning a rotor and stator within a well-pump are disclosed, wherein the well-pump has a whistle assembly formed at a bottom portion thereof, such that variations in the frequency of the whistle, indicating misalignment, may be monitored during pumping. 6 figs.

  6. Non-circulatory fluid forces on porous bodies with application to panel flutter

    NASA Astrophysics Data System (ADS)

    Hajian, Rozhin; Jaworski, Justin W.

    2017-11-01

    The non-circulatory fluid forces acting on an oscillating porous panel or airfoil in uniform incompressible flow are derived from linearized potential theory. The fundamental integral equation for Holder-continuous porosity distributions is formulated and solved numerically for the special cases of non-porous and uniformly-porous panels with prescribed structural deformations. The new unsteady aerodynamic forces are then applied to aeroelastic stability predictions for porous panels or liners. Results from this analysis aim to form the basis of a complete unsteady aerodynamic theory for porous airfoils and their acoustic emissions based upon the unique attributes of natural fliers and swimmers.

  7. Abdominal pain - children under age 12

    MedlinePlus

    Stomach pain in children; Pain - abdomen - children; Abdominal cramps in children; Belly ache in children ... When your child complains of abdominal pain, see if they can describe it to you. Here are different kinds of pain: ...

  8. Air-Operated Sump Pump

    NASA Technical Reports Server (NTRS)

    Nolt, Gary D.

    1988-01-01

    Pump removes liquid seepage from small, restricted area and against large pressure head. Developed for moving small amounts of water and oil from sump pit 85 ft (25.91 m) deep. Fits in space only 6 1/2 in. (16.5 cm) in diameter and 18 in. (45.7 cm) long. In discharge part of pumping cycle, air forces liquid out of pump chamber through pipe. During filling part of pumping cycle, water enters pump chamber from sump pit. Float in chamber next to pump chamber controls pressurization through timer and solenoid valve.

  9. Photovoltaic pump systems

    NASA Astrophysics Data System (ADS)

    Klockgether, J.; Kiessling, K. P.

    1983-09-01

    Solar pump systems for the irrigation of fields and for water supply in regions with much sunshine are discussed. For surface water and sources with a hoisting depth of 12 m, a system with immersion pumps is used. For deep sources with larger hoisting depths, an underwater motor pump was developed. Both types of pump system meet the requirements of simple installation and manipulation, safe operation, maintenance free, and high efficiency reducing the number of solar cells needed.

  10. Electrokinetic pump

    DOEpatents

    Patel, Kamlesh D.

    2007-11-20

    A method for altering the surface properties of a particle bed. In application, the method pertains particularly to an electrokinetic pump configuration where nanoparticles are bonded to the surface of the stationary phase to alter the surface properties of the stationary phase including the surface area and/or the zeta potential and thus improve the efficiency and operating range of these pumps. By functionalizing the nanoparticles to change the zeta potential the electrokinetic pump is rendered capable of operating with working fluids having pH values that can range from 2-10 generally and acidic working fluids in particular. For applications in which the pump is intended to handle highly acidic solutions latex nanoparticles that are quaternary amine functionalized can be used.

  11. Rotary blood pump

    NASA Astrophysics Data System (ADS)

    Bozeman, Richard J.; Akkerman, James W.; Aber, Greg S.; Vandamm, George A.; Bacak, James W.; Svejkovsky, Paul A.; Benkowski, Robert J.

    1993-11-01

    A rotary blood pump is presented. The pump includes a pump housing for receiving a flow straightener, a rotor mounted on rotor bearings and having an inducer portion and an impeller portion, and a diffuser. The entrance angle, outlet angle, axial, and radial clearances of the blades associated with the flow straightener, inducer portion, impeller portion, and diffuser are optimized to minimize hemolysis while maintaining pump efficiency. The rotor bearing includes a bearing chamber that is filled with crosslinked blood or other bio-compatible material. A back emf integrated circuit regulates rotor operation and a microcomputer may be used to control one or more back emf integrated circuits. A plurality of magnets are disposed in each of a plurality of impeller blades with a small air gap. A stator may be axially adjusted on the pump housing to absorb bearing load and maximize pump efficiency.

  12. Rotary blood pump

    NASA Technical Reports Server (NTRS)

    Bozeman, Richard J. (Inventor); Akkerman, James W. (Inventor); Aber, Greg S. (Inventor); Vandamm, George A. (Inventor); Bacak, James W. (Inventor); Svejkovsky, Paul A. (Inventor); Benkowski, Robert J. (Inventor)

    1993-01-01

    A rotary blood pump is presented. The pump includes a pump housing for receiving a flow straightener, a rotor mounted on rotor bearings and having an inducer portion and an impeller portion, and a diffuser. The entrance angle, outlet angle, axial, and radial clearances of the blades associated with the flow straightener, inducer portion, impeller portion, and diffuser are optimized to minimize hemolysis while maintaining pump efficiency. The rotor bearing includes a bearing chamber that is filled with crosslinked blood or other bio-compatible material. A back emf integrated circuit regulates rotor operation and a microcomputer may be used to control one or more back emf integrated circuits. A plurality of magnets are disposed in each of a plurality of impeller blades with a small air gap. A stator may be axially adjusted on the pump housing to absorb bearing load and maximize pump efficiency.

  13. Relations of Cognitive and Motivational Variables with Students' Human Circulatory System Achievement in Traditional and Learning Cycle Classrooms

    ERIC Educational Resources Information Center

    Sadi, Özlem; Çakiroglu, Jale

    2014-01-01

    This study is aimed at investigating the relationships among students' relevant prior knowledge, meaningful learning orientation, reasoning ability, self-efficacy, locus of control, attitudes toward biology and achievement with the human circulatory system (HCS) using the learning cycle (LC) and the traditional classroom setting. The study was…

  14. Study report on modification of the long term circulatory model for the simulation of bed rest

    NASA Technical Reports Server (NTRS)

    Leonard, J. I.; Grounds, D. J.

    1977-01-01

    Modifications were made of the circulatory, fluid, and electrolyte control model which was based on the model of Guyton. The modifications included separate leg compartments and the addition of gravity dependency. It was found that these modifications allowed for more accurate bed rest simulation by simulating changes in the orthostatic gradient and simulating the response to the fluid shifts associated with bed rest.

  15. Rotary piston blood pumps: past developments and future potential of a unique pump type.

    PubMed

    Wappenschmidt, Johannes; Autschbach, Rüdiger; Steinseifer, Ulrich; Schmitz-Rode, Thomas; Margreiter, Raimund; Klima, Günter; Goetzenich, Andreas

    2016-08-01

    The design of implantable blood pumps is either based on displacement pumps with membranes or rotary pumps. Both pump types have limitations to meet the clinical requirements. Rotary piston blood pumps have the potential to overcome these limitations and to merge the benefits. Compared to membrane pumps, they are smaller and with no need for wear-affected membranes and valves. Compared to rotary pumps, the blood flow is pulsatile instead of a non-physiological continuous flow. Furthermore, the risk of flow-induced blood damage and platelet activation may be reduced due to low shear stress to the blood. The past developments of rotary piston blood pumps are summarized and the main problem for long-term application is identified: insufficient seals. A new approach with seal-less drives is proposed and current research on a simplified rotary piston design is presented. Expert commentary: The development of blood pumps focuses mainly on the improvement of rotary pumps. However, medical complications indicate that inherent limitations of this pump type remain and restrict the next substantial step forward in the therapy of heart failure patients. Thus, research on different pump types is reasonable. If the development of reliable drives and bearings succeeds, rotary piston blood pumps become a promising alternative.

  16. Intra-abdominal pressure: an integrative review.

    PubMed

    Milanesi, Rafaela; Caregnato, Rita Catalina Aquino

    2016-01-01

    There is a growing request for measuring intra-abdominal pressure in critically ill patients with acute abdominal pain to be clarified. Summarizing the research results on measurement of vesical intra-abdominal pressure and analyzing the level of evidence were the purposes of this integrative literature review, carried out based on the databases LILACS, MEDLINE and PubMed, from 2005 to July 2012. Twenty articles were identified, in that, 12 literature reviews, 4 descriptive and exploratory studies, 2 expert opinions, one prospective cohort study and one was an experience report. The vesical intra-abdominal pressure measurement was considered gold standard. There are variations in the technique however, but some common points were identified: complete supine position, in absence of abdominal contracture, in the end of expiration and expressed in mmHg. Most research results indicate keeping the transducer zeroed at the level of the mid-axillary line at the iliac crest level, and instill 25mL of sterile saline. Strong evidence must be developed. RESUMO Em pacientes críticos com quadros abdominais agudos a esclarecer é crescente a solicitação da aferição da pressão intra-abdominal. Sintetizar resultados de pesquisas sobre a mensuração da pressão intra-abdominal pela via vesical e analisar o nível de evidência foram os objetivos desta revisão integrativa da literatura, realizada nas bases LILACS, MEDLINE e PubMed, no período de 2005 a julho de 2012. Identificaram-se 20 artigos, sendo 12 revisões de literatura, 4 estudos exploratório-descritivos, 2 opiniões de especialistas, 1 estudo de coorte prospectivo e 1 relato de experiência. O método vesical para mensuração da pressão intra-abdominal foi considerado padrão-ouro. Existem variações na técnica, entretanto pontos em comum foram identificados: posição supina completa, na ausência de contratura abdominal, ao final da expiração e expressa em mmHg. A maioria indica posicionar o ponto zero do

  17. Circulatory failure during severe hyperthermia in dog.

    PubMed

    Miki, K; Morimoto, T; Nose, H; Itoh, T; Yamada, S

    1983-01-01

    The effect of acute hyperthermia on circulatory function was studied in 6 mongrel dogs. At a core temperature of about 40 degrees C, central venous pressure and stroke volume were maintained at almost normal level. Cardiac output significantly increased (26 ml/(kg . min)) while systemic vascular resistance significantly decreased (1.2 mmHg . sec/ml). In addition, significant decrease in vascular compliance by 40% was observed. When body temperature was raised further (severe hyperthermia), an abrupt fall of arterial pressure was observed at the rectal temperature of about 41-42 degrees C. Concomitant decreases in central venous pressure (3 mmHg), stroke volume (2.1 ml/beat) and cardiac output (29 ml/(kg . min)) were observed while heart rate increased (48 beats/min). These results suggest that the decrease in cardiac output during severe hyperthermia is due to the fall of central venous pressure, and the fall was attributed to the increase in unstressed vascular volume of systemic circulation due to the heat-induced cutaneous vasodilation. The observed decrease in systemic vascular compliance is considered to have a significant role in the maintenance of central venous pressure under hyperthermia.

  18. Abdomino-phrenic dyssynergia in patients with abdominal bloating and distension.

    PubMed

    Villoria, Albert; Azpiroz, Fernando; Burri, Emanuel; Cisternas, Daniel; Soldevilla, Alfredo; Malagelada, Juan-R

    2011-05-01

    The abdomen normally accommodates intra-abdominal volume increments. Patients complaining of abdominal distension exhibit abnormal accommodation of colonic gas loads (defective contraction and excessive protrusion of the anterior wall). However, abdominal imaging demonstrated diaphragmatic descent during spontaneous episodes of bloating in patients with functional gut disorders. We aimed to establish the role of the diaphragm in abdominal distension. In 20 patients complaining of abdominal bloating and 15 healthy subjects, we increased the volume of the abdominal cavity with a colonic gas load, while measuring abdominal girth and electromyographic activity of the anterior abdominal muscles and of the diaphragm. In healthy subjects, the colonic gas load increased girth, relaxed the diaphragm, and increased anterior wall tone. With the same gas load, patients developed significantly more abdominal distension; this was associated with paradoxical contraction of the diaphragm and relaxation of the internal oblique muscle. In this experimental provocation model, abnormal accommodation of the diaphragm is involved in abdominal distension.

  19. Numerical Models of Human Circulatory System under Altered Gravity: Brain Circulation

    NASA Technical Reports Server (NTRS)

    Kim, Chang Sung; Kiris, Cetin; Kwak, Dochan; David, Tim

    2003-01-01

    A computational fluid dynamics (CFD) approach is presented to model the blood flow through the human circulatory system under altered gravity conditions. Models required for CFD simulation relevant to major hemodynamic issues are introduced such as non-Newtonian flow models governed by red blood cells, a model for arterial wall motion due to fluid-wall interactions, a vascular bed model for outflow boundary conditions, and a model for auto-regulation mechanism. The three-dimensional unsteady incompressible Navier-Stokes equations coupled with these models are solved iteratively using the pseudocompressibility method and dual time stepping. Moving wall boundary conditions from the first-order fluid-wall interaction model are used to study the influence of arterial wall distensibility on flow patterns and wall shear stresses during the heart pulse. A vascular bed modeling utilizing the analogy with electric circuits is coupled with an auto-regulation algorithm for multiple outflow boundaries. For the treatment of complex geometry, a chimera overset grid technique is adopted to obtain connectivity between arterial branches. For code validation, computed results are compared with experimental data for steady and unsteady non-Newtonian flows. Good agreement is obtained for both cases. In sin-type Gravity Benchmark Problems, gravity source terms are added to the Navier-Stokes equations to study the effect of gravitational variation on the human circulatory system. This computational approach is then applied to localized blood flows through a realistic carotid bifurcation and two Circle of Willis models, one using an idealized geometry and the other model using an anatomical data set. A three- dimensional anatomical Circle of Willis configuration is reconstructed from human-specific magnetic resonance images using an image segmentation method. The blood flow through these Circle of Willis models is simulated to provide means for studying gravitational effects on the brain

  20. Segmentation of images of abdominal organs.

    PubMed

    Wu, Jie; Kamath, Markad V; Noseworthy, Michael D; Boylan, Colm; Poehlman, Skip

    2008-01-01

    Abdominal organ segmentation, which is, the delineation of organ areas in the abdomen, plays an important role in the process of radiological evaluation. Attempts to automate segmentation of abdominal organs will aid radiologists who are required to view thousands of images daily. This review outlines the current state-of-the-art semi-automated and automated methods used to segment abdominal organ regions from computed tomography (CT), magnetic resonance imaging (MEI), and ultrasound images. Segmentation methods generally fall into three categories: pixel based, region based and boundary tracing. While pixel-based methods classify each individual pixel, region-based methods identify regions with similar properties. Boundary tracing is accomplished by a model of the image boundary. This paper evaluates the effectiveness of the above algorithms with an emphasis on their advantages and disadvantages for abdominal organ segmentation. Several evaluation metrics that compare machine-based segmentation with that of an expert (radiologist) are identified and examined. Finally, features based on intensity as well as the texture of a small region around a pixel are explored. This review concludes with a discussion of possible future trends for abdominal organ segmentation.

  1. Mechanical circulatory support in pediatrics

    PubMed Central

    De Rita, Fabrizio; Hasan, Asif; Griselli, Massimo

    2014-01-01

    There is no reliable published data on the overall prevalence or incidence of heart failure (HF) in children. However, the success of mechanical circulatory support (MCS) in management of HF has raised the prospect of a previously unavailable treatment modality. Orthotopic heart transplant (OHTx) remains the gold standard treatment, but the number of patients requiring this treatment far outweighs the donor availability. It is therefore not surprising to see the popularity of various MCS modalities, with different devices ranging from veno-arterial extra corporeal membrane oxygenation (VA-ECMO) to ventricular assist devices (VADs), which are either para-corporeal or intra-corporeal, with pulsatile or continuous flow. Indication, timing and the choice of the type of mechanical support are crucial so in order to avoid potential lethal complications such as hemorrhage, thrombo-embolism and infections. In the pediatric population, MCS is used mainly as bridge to transplantation but can be used as bridge to recovery in patients with acute myocarditis or following open-heart surgery. Active research is currently underway to develop newer and more durable devices that will assist the pediatric population across all age groups. This research will support different pathologies that have lower incidences of major morbidities, particularly as greater durations of MCS are expected due to a paucity of donors for OHTx. The combined experience developed through the usage of different devices in pediatric and adult populations has led to the to the application of MCS in some subgroups of grown–up congenital heart diseases (CHDs) patients, particularly those with systemic right ventricular failure. PMID:25452912

  2. Antithrombin III is associated with acute liver failure in patients with end-stage heart failure undergoing mechanical circulatory support.

    PubMed

    Hoefer, Judith; Ulmer, Hanno; Kilo, Juliane; Margreiter, Raimund; Grimm, Michael; Mair, Peter; Ruttmann, Elfriede

    2017-06-01

    There are few data on the role of liver dysfunction in patients with end-stage heart failure supported by mechanical circulatory support. The aim of our study was to investigate predictors for acute liver failure in patients with end-stage heart failure undergoing mechanical circulatory support. A consecutive 164 patients with heart failure with New York Heart Association class IV undergoing mechanical circulatory support were investigated for acute liver failure using the King's College criteria. Clinical characteristics of heart failure together with hemodynamic and laboratory values were analyzed by logistic regression. A total of 45 patients (27.4%) with heart failure developed subsequent acute liver failure with a hospital mortality of 88.9%. Duration of heart failure, cause, cardiopulmonary resuscitation, use of vasopressors, central venous pressure, pulmonary capillary wedge pressure, pulmonary pulsatility index, cardiac index, and transaminases were not significantly associated with acute liver failure. Repeated decompensation, atrial fibrillation (P < .001) and the use of inotropes (P = .007), mean arterial (P = .005) and pulmonary pressures (P = .042), cholinesterase, international normalized ratio, bilirubin, lactate, and pH (P < .001) were predictive of acute liver failure in univariate analysis only. In multivariable analysis, decreased antithrombin III was the strongest single measurement indicating acute liver failure (relative risk per %, 0.84; 95% confidence interval, 0.77-0.93; P = .001) and remained an independent predictor when adjustment for the Model for End-Stage Liver Disease score was performed (relative risk per %, 0.89; 95% confidence interval, 0.80-0.99; P = .031). Antithrombin III less than 59.5% was identified as a cutoff value to predict acute liver failure with a corresponding sensitivity of 81% and specificity of 87%. In addition to the Model for End-Stage Liver Disease score, decreased antithrombin III activity tends

  3. Abdominal Pain in the Geriatric Patient.

    PubMed

    Leuthauser, Amy; McVane, Benjamin

    2016-05-01

    Abdominal pain in the elderly can be a challenging and difficult condition to diagnose and treat. The geriatric population has significant comorbidities and often takes polypharmacy that can mask symptoms. The presentation of common conditions can be different than that in the younger population, often lacking the traditional indicators of disease, making it of pivotal importance for the clinician to consider a wide differential during their workup. It is also important to consider extra-abdominal abnormality that may manifest as abdominal pain. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Abdominal pain in children with sickle cell disease.

    PubMed

    Rhodes, Melissa M; Bates, David Gregory; Andrews, Tina; Adkins, Laura; Thornton, Jennifer; Denham, Jolanda M

    2014-02-01

    The differential diagnosis of abdominal pain is broad in any child, and further complicated in children with sickle cell disease (SCD). Acute causes of abdominal pain may require emergent surgery, such as for appendicitis or obstruction caused by a bezoar. Rapid intervention is necessary and life-saving in children with SCD and acute splenic or hepatic sequestration. The majority of children with SCD presenting to the physician's office or emergency department will have subacute reasons for their abdominal pain, including but not limited to constipation, urinary tract infection, peptic ulcer disease, and cholecystitis. Vaso-occlusive pain often presents in children as abdominal pain, but is a diagnosis of exclusion. The case of a 10-year-old girl with intermittent abdominal pain is used as a starting point to review the pathophysiology, diagnosis, and treatment of the most acute and common causes of abdominal pain in children with SCD.

  5. Compliance of the abdominal wall during laparoscopic insufflation.

    PubMed

    Becker, Chuck; Plymale, Margaret A; Wennergren, John; Totten, Crystal; Stigall, Kyle; Roth, J Scott

    2017-04-01

    To provide adequate workspace between the viscera and abdominal wall, insufflation with carbon dioxide is a common practice in laparoscopic surgeries. An insufflation pressure of 15 mmHg is considered to be safe in patients, but all insufflation pressures create perioperative and postoperative physiologic effects. As a composition of viscoelastic materials, the abdominal wall should distend in a predictable manner given the pressure of the pneumoperitoneum. The purpose of this study was to elucidate the relationship between degree of abdominal distention and the insufflation pressure, with the goal of determining factors which impact the compliance of the abdominal wall. A prospective, IRB-approved study was conducted to video record the abdomens of patients undergoing insufflation prior to a laparoscopic surgery. Photo samples were taken every 5 s, and the strain of the patient's abdomen in the sagittal plane was determined, as well as the insufflator pressure (stress) at bedside. Patients were insufflated to 15 mmHg. The relationship between the stress and strain was determined in each sample, and compliance of the patient's abdominal wall was calculated. Subcutaneous fat thickness and rectus abdominus muscle thickness were obtained from computed tomography scans. Correlations between abdominal wall compliances and subcutaneous fat and muscle content were determined. Twenty-five patients were evaluated. An increased fat thickness in the abdominal wall had a direct exponential relationship with abdominal wall compliance (R 2  = 0.59, p < 0.05). There was no correlation between muscle and fat thickness. All insufflation pressures create perioperative and postoperative complications. The compliance of patients' abdominal body walls differs, and subcutaneous fat thickness has a direct exponential relationship with abdominal wall compliance. Thus, insufflation pressures can be better tailored per the patient. Future studies are needed to demonstrate the

  6. Abdominal pregnancy - Case presentation.

    PubMed

    Bohiltea, R; Radoi, V; Tufan, C; Horhoianu, I A; Bohiltea, C

    2015-01-01

    Abdominal pregnancy, a rare diagnosis, belongs to the ectopic pregnancy group, the leading cause of pregnancy related exitus. The positive diagnosis is very difficult to establish most often in an acute setting, leading to a staggering percent of feto-maternal morbidity and mortality. We present the case of 26-weeks-old abdominal pregnancy with partial feto-placental detachment in a patient, after hysteroscopy and in vitro fertilization, which until the acute symptoms that led to emergency laparotomy went unrecognized. The patient recovered completely and satisfactorily after surgery and, due to the high risk of uterine rupture with regard to a second pregnancy, opted for a surrogate mother. Abdominal pregnancy can be regarded as a difficult to establish diagnosis, with a greater chance in case of increased awareness. It is compulsory to be well informed in order not to be surprised by the diagnosis and to apply the correct treatment immediately as the morbidity and mortality rate is elevated.

  7. ION PUMP

    DOEpatents

    Milleron, N.

    1961-01-01

    An ion pump and pumping method are given for low vacuum pressures in which gases introduced into a pumping cavity are ionized and thereafter directed and accelerated into a quantity of liquid gettering metal where they are absorbed. In the preferred embodiment the metal is disposed as a liquid pool upon one electrode of a Phillips ion gauge type pump. Means are provided for continuously and remotely withdrawing and degassing the gettering metal. The liquid gettering metal may be heated if desired, although various combinations of gallium, indium, tin, bismuth, and lead, the preferred metals, have very low melting points. A background pressure of evaporated gettering metal may be provided by means of a resistance heated refractory metal wick protruding from the surface of the pcol of gettering metal.

  8. Treatment strategy for ruptured abdominal aortic aneurysms.

    PubMed

    Davidovic, L

    2014-07-01

    Rupture is the most serious and lethal complication of the abdominal aortic aneurysm. Despite all improvements during the past 50 years, ruptured abdominal aortic aneurysms are still associated with very high mortality. Namely, including patients who die before reaching the hospital, the mortality rate due to abdominal aortic aneurysm rupture is 90%. On the other hand, during the last twenty years, the number of abdominal aortic aneurysms significantly increased. One of the reasons is the fact that in majority of countries the general population is older nowadays. Due to this, the number of degenerative AAA is increasing. This is also the case for patients with abdominal aortic aneurysm rupture. Age must not be the reason of a treatment refusal. Optimal therapeutic option ought to be found. The following article is based on literature analysis including current guidelines but also on my Clinics significant experience. Furthermore, this article show cases options for vascular medicine in undeveloped countries that can not apply endovascular procedures at a sufficient level and to a sufficient extent. At this moment the following is evident. Thirty-day-mortality after repair of ruptured abdominal aortic aneurysms is significantly lower in high-volume hospitals. Due to different reasons all ruptured abdominal aortic aneurysms are not suitable for EVAR. Open repair of ruptured abdominal aortic aneurysm should be performed by experienced open vascular surgeons. This could also be said for the treatment of endovascular complications that require open surgical conversion. There is no ideal procedure for the treatment of AAA. Each has its own advantages and disadvantages, its own limits and complications, as well as indications and contraindications. Future reductions in mortality of ruptured abdominal aortic aneurysms will depend on implementation of population-based screening; on strategies to prevent postoperative organ injury and also on new medical technology

  9. Liquid metal enabled pump

    PubMed Central

    Tang, Shi-Yang; Khoshmanesh, Khashayar; Sivan, Vijay; Petersen, Phred; O’Mullane, Anthony P.; Abbott, Derek; Mitchell, Arnan; Kalantar-zadeh, Kourosh

    2014-01-01

    Small-scale pumps will be the heartbeat of many future micro/nanoscale platforms. However, the integration of small-scale pumps is presently hampered by limited flow rate with respect to the input power, and their rather complicated fabrication processes. These issues arise as many conventional pumping effects require intricate moving elements. Here, we demonstrate a system that we call the liquid metal enabled pump, for driving a range of liquids without mechanical moving parts, upon the application of modest electric field. This pump incorporates a droplet of liquid metal, which induces liquid flow at high flow rates, yet with exceptionally low power consumption by electrowetting/deelectrowetting at the metal surface. We present theory explaining this pumping mechanism and show that the operation is fundamentally different from other existing pumps. The presented liquid metal enabled pump is both efficient and simple, and thus has the potential to fundamentally advance the field of microfluidics. PMID:24550485

  10. Computed tomographic evaluation of abdominal fat in minipigs.

    PubMed

    Chang, Jinhwa; Jung, Joohyun; Lee, Hyeyeon; Chang, Dongwoo; Yoon, Junghee; Choi, Mincheol

    2011-03-01

    Computed tomography (CT) exams were conducted to determine the distribution of abdominal fat identified based on the CT number measured in Hounsfield Units (HU) and to measure the volume of the abdominal visceral and subcutaneous fat in minipigs. The relationship between the CT-based fat volumes of several vertebral levels and the entire abdomen and anthropometric data including the sagittal abdominal diameter and waist circumference were evaluated. Moreover, the total fat volumes at the T11, T13, L3, and L5 levels were compared with the total fat volume of the entire abdomen to define the landmark of abdominal fat distribution. Using a single-detector CT, six 6-month-old male minipigs were scanned under general anesthesia. Three radiologists then assessed the HU value of visceral and subcutaneous abdominal fat by drawing the region of interest manually at the T11, T13, L1, L3, and L5 levels. The CT number and abdominal fat determined in this way by the three radiologists was found to be correlated (intra-class coefficient = 0.9). The overall HU ranges for the visceral and subcutaneous fat depots were -147.47 to -83.46 and -131.62 to -90.97, respectively. The total fat volume of the entire abdomen was highly correlated with the volume of abdominal fat at the T13 level (r = 0.97, p < 0.0001). These findings demonstrate that the volume of abdominal adipose tissue measured at the T13 level using CT is a strong and reliable predictor of total abdominal adipose volume.

  11. [THE CHARACTERISTIC OF SOMATOTYPE AND FUNCTIONAL STATE OF CIRCULATORY SYSTEM OF STUDENT YOUTH OF THE NORTHEAST OF RUSSIA].

    PubMed

    Timofeieva, A V; Klimova, T M; Mikhailova, A E; Zakharova, R N; Vinokurova, S P; Timofeiev, L F

    2015-01-01

    The article considers results of single-step study in random sampling of female students of the M.K. Ammosov north-east federal university (n=456). The study was carried out to investigate somatotype and functional state of circulatory system. The standard technique was applied to measure height, body mass, chest circumference, level of arterial pressure and rate of heart beats. The type of somatotype was established using Pignet index. The tone of vegetative system was determined using Kérdö index. The adaptation potential of circulatory system was determined using functional changes index. The results of study established that in 61% of examined female students the type of constitution corresponds to normosthenic one. The percentage of persons with asthenic and hypersthenic type of constitution amounted to 27% and 12% correspondingly. The signs of increasing oftone ofsympathetic nervous system are observed in 89% of girls. The functional condition of circulatory system is evaluated as "tension of adaptation mechanisms" that is apparently related to period of adaptation to new conditions. The prolonged preservation of such states results in exhaustion offunctional resources of organism and can promote development of diseases. In conditions of impacting of unfavorable ecological factors the deconditionning disorders can significantly contribute to health disturbances and decreasing of life quality. To preserve youth's health during period of education the comprehensive strategy is to be implemented such components as dynamic monitoring of health, organization of adequate diet, explanation of necessity of observance of sleep and rest pattern, development of conditions for active aerobic physical exertion and activities on correction of risk factors of development of diseases are to be included.

  12. [Abdominal catastrophe--abdominal wall defect associated with gastrointestinal fistula--strategy of therapy].

    PubMed

    Chobola, M; Sobotka, L; Ferko, A; Oberreiter, M; Kaska, M; Motycka, V; Páral, J; Mottl, R

    2010-11-01

    Wound dehiscence complicated by gastrointestinal (GI) fistula to belong ,,abdominal catastrophe". Therapy is prolonged and connected with high morbidity and mortality rate. In the period from October 2006 to July 2009 we performed 12 reconstructive surgical procedures on gastrointestinal tract in patients with abdominal catastrophe. Treatment of 12 consecutive patients (9 men, 3 women) was managed according to a standardize protocol. The protocol consists of treatment of septic complications, optimisation of nutritional state, special wound procedures, diagnosis of gastrointestinal fistulas and GI tract, timing of surgical procedures, reconstruction of GI tract and postoperative care. Reconstructive surgery of GI tract was successful on 11 patients. One patient developed recurrence of early GI fistula. In four patients we let open abdomen to heal per secundam. We observed no deaths after operation. With regard to complex character of therapy of abdominal catastrophe there is a need of multidisciplinary approach. Considering long-lasting and expensive therapy there is logical step to concentrate these patients into special centres which are experienced, equipped and their staff is trained in treatment of such a seriously impaired patients.

  13. Abdominal rigidity

    MedlinePlus

    ... other symptoms do you have at the same time? For example, do you have abdominal pain ? You may have the following tests: Barium studies of the stomach and intestines (such as an upper GI series ) Blood tests Colonoscopy Gastroscopy Peritoneal lavage Stool studies ...

  14. 20. ENGINE/PUMP HOUSE EXTENSION, PUMP NO. 4, HOUSING FOR ECCENTRICS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    20. ENGINE/PUMP HOUSE EXTENSION, PUMP NO. 4, HOUSING FOR ECCENTRICS THAT CONTROL THE STEAM FOR EAST PISTON LOCATED BELOW THE PISTON CRANKSHAFT HUB AND ABOVE THE THRUST BEARING; CONTROL RODS FOR PISTON NO. 3 LOCATED AT RIGHT. - Deer Island Pumping Station, Boston, Suffolk County, MA

  15. Organ Donation After Circulatory Death: Ethical Issues and International Practices.

    PubMed

    Jericho, Barbara G

    2018-05-21

    Donation after circulatory death (DCD) is an increasingly utilized practice that can contribute to reducing the difference between the supply of organs and the demand for organs for transplantation. As the number of transplanted organs from DCD donors continues to increase, there is an essential need to address the ethical aspects of DCD in institutional DCD protocols and clinical practice. Ethical issues of respecting the end-of-life wishes of a potential donor, respecting a recipient's wishes, and addressing potential conflicts of interest are important considerations in developing policies and procedures for DCD programs. Although there may be diversity among DCD programs in Europe, Australia, Israel, China, the United States, and Canada, addressing ethical considerations in these DCD programs is essential to respect donors and recipients during the altruistic and generous act of organ donation.

  16. Getting home with artifical heart – what is the everyday life experience of people with mechanical circulatory Support. A qualitative study

    PubMed

    Braunsdorf, Sandy

    2017-07-01

    Background: The growing number of mechanical circulatory support systems implanted with successful results in terms of quality of life and physical resilience means that more and more people are being discharged from hospital to live at home with an artificial heart. This puts high requirements on affected persons’ disease and therapy management – a subject which has attracted very little qualitative research to date. Aim: This study therefore sought to shed light on how people with mechanical circulatory support experience their everyday lives. The aim was to document the subjective associations of those affected from an insider perspective. Methods: Following the interpretative phenomenological paradigm, narrative interviews were conducted with two female and eight male participants. For qualitative analysis, a multi-step process guided by the methodology of hermeneutic philosophy was used. Results: The qualitative data analysis revealed five main topic areas. These describe patients’ state of health after implantation and the various adjustments, constraints and pressures necessitated by their illness and therapeutic requirements. On this basis, coping and management strategies are identified. Other significant aspects of patients’ everyday lives are social interaction and environment and health care with an artificial heart. Conclusions: The findings add to our knowledge of the day-to-day lives of people with mechanical circulatory support systems, giving us a better understanding of their specific situation.

  17. Measure Guideline: Replacing Single-Speed Pool Pumps with Variable Speed Pumps for Energy Savings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hunt, A.; Easley, S.

    2012-05-01

    The report evaluates potential energy savings by replacing traditional single-speed pool pumps with variable speed pool pumps, and provide a basic cost comparison between continued uses of traditional pumps verses new pumps. A simple step-by-step process for inspecting the pool area and installing a new pool pump follows.

  18. Abdominal exploration - slideshow

    MedlinePlus

    ... ency/presentations/100049.htm Abdominal exploration - series—Normal ... intestine (jejunum and ileum), the large intestine (colon), the liver, the spleen, the gallbladder, the pancreas, the uterus, ...

  19. Diode-pumped laser with improved pumping system

    DOEpatents

    Chang, Jim J.

    2004-03-09

    A laser wherein pump radiation from laser diodes is delivered to a pump chamber and into the lasing medium by quasi-three-dimensional compound parabolic concentrator light channels. The light channels have reflective side walls with a curved surface and reflective end walls with a curved surface. A flow tube between the lasing medium and the light channel has a roughened surface.

  20. Revealing a new mode of sensitization induced by mechanical circulatory support devices: Impact of anti-AT1 R antibodies.

    PubMed

    Zhang, Xiaohai; Mirocha, James; Aintablian, Tamar; Dimbil, Sadia; Moriguchi, Jaime; Arabia, Francisco; Kobashigawa, Jon A; Reinsmoen, Nancy

    2018-02-01

    Increased levels of angiotensin II type 1 receptor (AT 1 R) antibody have been shown to be associated with allograft rejection. This study aims to determine the rate of development of antibody to AT 1 R after mechanical circulatory support device (MCS) implantation, and if the development of strong binding AT 1 R antibodies is associated with survival. Eighty-eight patients who had one MCS implantation were accessed based on serum availability. Mechanical circulatory support devices in this cohort included pneumatic bilateral paracorporeal ventricular assist device, continuous flow left ventricular assist device, and total artificial heart. Of 88 patients, seven patients had AT 1 R antibodies ≥40 U/mL preimplantation. For 81 patients who had AT 1 R antibodies <40 U/mL, the median value was 8 U/mL. Of these 81 patients, AT 1 R antibody levels in 55 (68%) patients reached the saturated concentration (≥40 U/mL) postimplantation (P < .0001), with the highest percentage of patients with the saturated level of AT 1 R antibody observed in the pneumatic bilateral paracorporeal ventricular assist device group. Compared to patients without the saturated level of AT 1 R antibodies, patients with the saturated AT 1 R antibody level had lower 18-month survival (P = .040). Mechanical circulatory support devices implantation significantly increases AT 1 R antibody levels. The saturated level of AT 1 R antibodies is associated with lower patient survival postimplantation. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Donation After Circulatory Death for Liver Transplantation: A Meta-Analysis on the Location of Life Support Withdrawal Affecting Outcomes.

    PubMed

    Cao, Yiming; Shahrestani, Sara; Chew, Hong Chee; Crawford, Michael; Macdonald, Peter Simon; Laurence, Jerome; Hawthorne, Wayne John; Dhital, Kumud; Pleass, Henry

    2016-07-01

    Liver transplantation using donation after circulatory death (DCD) donors is associated with inferior outcomes compared to donation after brain death (DBD). Prolonged donor warm ischemic time has been identified as the key factor responsible for this difference. Various aspects of the donor life support withdrawal procedure, including location of withdrawal and administration of antemortem heparin, are thought to play important roles in mitigating the effects of warm ischemia. However, a systematic exploration of these factors is important for more confident integration of these practices into a standard DCD protocol. Medline, EMBASE, and Cochrane libraries were systematically searched and 23 relevant studies identified for analysis. Donation after circulatory death recipients were stratified according to location of life support withdrawal (intensive care unit or operating theater) and use of antemortem heparin. Donation after circulatory death recipients had comparable 1-year patient survival to DBD recipients if the location of withdrawal of life support was the operating theater, but not if the location was the intensive care unit. Likewise, the inferior 1-year graft survival and higher incidence of ischemic cholangiopathy of DCD compared with DBD recipients were improved by withdrawal in operating theater, although higher rates of ischemic cholangiopathy and worse graft survival were still observed in DCD recipients. Furthermore, administering heparin before withdrawal of life support reduced the incidence of primary nonfunction of the allograft. Our evidence suggests that withdrawal in the operating theater and premortem heparin administration improve DCD liver transplant outcomes, thus allowing for the most effective usage of these valuable organs.

  2. Hazardous Chemical Pump Tests.

    DTIC Science & Technology

    1980-07-01

    hydraulic flow rate is the product of the pump speed and the pump displacement. The pump displacement for each respective pump was constant throughout...speed - rpm T - torque - ft lbs 7= 3.1416 By substituting the product of pump speed and pump displacement for the hydraulic flow rate (Q=NO) in the above...FF:iipr’: iL 40 H FLUID F-’UMPED; FPl H FVIi T’E1l ’HJO I...S Lu FL: H KFITE C F~~:ri FIGURE 2 CC E MT 2, Fi C F . c ;E’C F11 *:;_cl PF fog O ~ \\ 4 1

  3. Successful Treatment of Abdominal Cutaneous Entrapment Syndrome Using Ultrasound Guided Injection

    PubMed Central

    Hong, Myong Joo; Seo, Dong Hyuk

    2013-01-01

    There are various origins for chronic abdominal pain. About 10-30% of patients with chronic abdominal pain have abdominal wall pain. Unfortunately, abdominal wall pain is not thought to be the first origin of chronic abdominal pain; therefore, patients usually undergo extensive examinations, including diagnostic laparoscopic surgery. Entrapment of abdominal cutaneous nerves at the muscular foramen of the rectus abdominis is a rare cause of abdominal wall pain. If abdominal wall pain is considered in earlier stage of chronic abdominal pain, unnecessary invasive procedures are not required and patients will reach symptom free condition as soon as the diagnosis is made. Here, we report a case of successful treatment of a patient with abdominal cutaneous nerve entrapment syndrome by ultrasound guided injection therapy. PMID:23862004

  4. Measure Guideline. Replacing Single-Speed Pool Pumps with Variable Speed Pumps for Energy Savings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hunt, A.; Easley, S.

    2012-05-01

    This measure guideline evaluates potential energy savings by replacing traditional single-speed pool pumps with variable speed pool pumps, and provides a basic cost comparison between continued uses of traditional pumps verses new pumps. A simple step-by-step process for inspecting the pool area and installing a new pool pump follows.

  5. Optimization of a miniature Maglev ventricular assist device for pediatric circulatory support.

    PubMed

    Zhang, Juntao; Koert, Andrew; Gellman, Barry; Gempp, Thomas M; Dasse, Kurt A; Gilbert, Richard J; Griffith, Bartley P; Wu, Zhongjun J

    2007-01-01

    A miniature Maglev blood pump based on magnetically levitated bearingless technology is being developed and optimized for pediatric patients. We performed impeller optimization by characterizing the hemodynamic and hemocompatibility performances using a combined computational and experimental approach. Both three-dimensional flow features and hemolytic characteristics were analyzed using computational fluid dynamics (CFD) modeling. Hydraulic pump performances and hemolysis levels of three different impeller designs were quantified and compared numerically. Two pump prototypes were constructed from the two impeller designs and experimentally tested. Comparison of CFD predictions with experimental results showed good agreement. The optimized impeller remarkably increased overall pump hydraulic output by more than 50% over the initial design. The CFD simulation demonstrated a clean and streamlined flow field in the main flow path. The numerical results by hemolysis model indicated no significant high shear stress regions. Through the use of CFD analysis and bench-top testing, the small pediatric pump was optimized to achieve a low level of blood damage and improved hydraulic performance and efficiency. The Maglev pediatric blood pump is innovative due to its small size, very low priming volume, excellent hemodynamic and hematologic performance, and elimination of seal-related and bearing-related failures due to adoption of magnetically levitated bearingless motor technology, making it ideal for pediatric applications.

  6. Chronic abdominal wall pain--a diagnostic challenge for the surgeon.

    PubMed

    Lindsetmo, Rolv-Ole; Stulberg, Jonah

    2009-07-01

    Chronic abdominal wall pain (CAWP) occurs in about 30% of all patients presenting with chronic abdominal pain. The authors review the literature identified in a PubMed search regarding the abdominal wall as the origin of chronic abdominal pain. CAWP is frequently misinterpreted as visceral or functional abdominal pain. Misdiagnosis often leads to a variety of investigational procedures and even abdominal operations with negative results. With a simple clinical test (Carnett's test), >90% of patients with CAWP can be recognized, without risk for missing intra-abdominal pathology. The condition can be confirmed when the injection of local anesthetics in the trigger point(s) relieves the pain. A fasciotomy in the anterior abdominal rectus muscle sheath through the nerve foramina of the affected branch of one of the anterior intercostal nerves heals the pain.

  7. [Severe fat embolism in perioperative abdominal liposuction and fat grafting].

    PubMed

    de Lima E Souza, Rodrigo; Apgaua, Bruno Tavares; Milhomens, João Daniel; Albuquerque, Francisco Tadeu Motta; Carneiro, Luiz Antônio; Mendes, Márcio Henrique; Garcia, Tiago Carvalho; Paiva, Clerisson; Ladeia, Felipe; Jeunon, Deiler Célio

    2016-01-01

    Fat embolism syndrome (FES) may occur in patients suffering from multiple trauma (long bone fractures) or plastic surgery (liposuction), compromising the circulatory, respiratory and/or central nervous systems. This report shows the evolution of severe FES after liposuction and fat grafting. SSS, 42 years old, ASA 1, no risk factors for thrombosis, candidate for abdominal liposuction and breast implant prosthesis. Subjected to balanced general anesthesia with basic monitoring and controlled ventilation. After 45minutes of procedure, there was a sudden and gradual decrease of capnometry, severe hypoxemia and hypotension. The patient was immediately monitored for MAP and central catheter, treated with vasopressors, inotropes, and crystalloid infusion, stabilizing her condition. Arterial blood sample showed pH = 7.21; PCO2 = 51mmHg; PO2 = 52mmHg; BE = -8; HCO3 = 18 mEq/L, and lactate = 6.0 mmol/L. Transthoracic echocardiogram showed PASP = 55mmHg, hypocontractile VD and LVEF = 60%. Diagnosis of pulmonary embolism. After 24h of intensive treatment, the patient developed anisocoria and coma (glasgow coma scale = 3). A brain CT was performed which showed severe cerebral hemispheric ischemia with signs of fat emboli in right middle cerebral artery; transesophageal echocardiography showed a patent foramen ovale. Finally, after 72h of evolution, the patient progressed to brain death. FES usually occurs in young people. Treatment is based mainly on the infusion of fluids and vasoactive drugs, mechanical ventilation, and triggering factor correction (early fixation of fractures or suspension of liposuction). The multiorgânico involvement indicates a worse prognosis. Copyright © 2014 Sociedade Brasileira de Anestesiologia. Publicado por Elsevier Editora Ltda. All rights reserved.

  8. Severe fat embolism in perioperative abdominal liposuction and fat grafting.

    PubMed

    de Lima E Souza, Rodrigo; Apgaua, Bruno Tavares; Milhomens, João Daniel; Albuquerque, Francisco Tadeu Motta; Carneiro, Luiz Antônio; Mendes, Márcio Henrique; Garcia, Tiago Carvalho; Paiva, Clerisson; Ladeia, Felipe; Jeunon, Deiler Célio

    2016-01-01

    Fat embolism syndrome may occur in patients suffering from multiple trauma (long bone fractures) or plastic surgery (liposuction), compromising the circulatory, respiratory and/or central nervous systems. This report shows the evolution of severe fat embolism syndrome after liposuction and fat grafting. SSS, 42 years old, ASA 1, no risk factors for thrombosis, candidate for abdominal liposuction and breast implant prosthesis. Subjected to balanced general anesthesia with basic monitoring and controlled ventilation. After 45min of procedure, there was a sudden and gradual decrease of capnometry, severe hypoxemia and hypotension. The patient was immediately monitored for MAP and central catheter, treated with vasopressors, inotropes, and crystalloid infusion, stabilizing her condition. Arterial blood sample showed pH=7.21; PCO2=51mmHg; PO2=52mmHg; BE=-8; HCO3=18mEqL(-1), and lactate=6.0mmolL(-1). Transthoracic echocardiogram showed PASP=55mmHg, hypocontractile VD and LVEF=60%. Diagnosis of pulmonary embolism. After 24h of intensive treatment, the patient developed anisocoria and coma (Glasgow coma scale=3). A brain CT was performed which showed severe cerebral hemispheric ischemia with signs of fat emboli in right middle cerebral artery; transesophageal echocardiography showed a patent foramen ovale. Finally, after 72h of evolution, the patient progressed to brain death. Fat embolism syndrome usually occurs in young people. Treatment is based mainly on the infusion of fluids and vasoactive drugs, mechanical ventilation, and triggering factor correction (early fixation of fractures or suspension of liposuction). The multiorgânico involvement indicates a worse prognosis. Copyright © 2014 Sociedade Brasileira de Anestesiologia. Published by Elsevier Editora Ltda. All rights reserved.

  9. Mechanisms and management of functional abdominal pain.

    PubMed

    Farmer, Adam D; Aziz, Qasim

    2014-09-01

    Functional abdominal pain syndrome is characterised by frequent or continuous abdominal pain associated with a degree of loss of daily activity. It has a reported population prevalence of between 0.5% and 1.7%, with a female preponderance. The pathophysiology of functional abdominal pain is incompletely understood although it has been postulated that peripheral sensitisation of visceral afferents, central sensitisation of the spinal dorsal horn and aberrancies within descending modulatory systems may have an important role. The management of patients with functional abdominal pain requires a tailored multidisciplinary approach in a supportive and empathetic environment in order to develop an effective therapeutic relationship. Patient education directed towards an explanation of the pathophysiology of functional abdominal pain is in our opinion a prerequisite step and provides the rationale for the introduction of interventions. Interventions can usefully be categorised into general measures, pharmacotherapy, psychological interventions and 'step-up' treatments. Pharmacotherapeutic/step-up options include tricyclic antidepressants, serotonin noradrenergic reuptake inhibitors and the gabapentinoids. Psychological treatments include cognitive behavioural therapy and hypnotherapy. However, the objective evidence base for these interventions is largely derived from other chronic pain syndrome, and further research is warranted in adult patients with functional abdominal pain. © The Royal Society of Medicine.

  10. Resonantly diode-pumped Er:YAG laser: 1470-nm versus 1530-nm CW pumping case

    NASA Astrophysics Data System (ADS)

    Kudryashov, Igor; Ter-Gabrielyan, Nikolai; Dubinskii, Mark

    2009-05-01

    Growing interest to high power lasers in the eye-safe spectral domain initiated a new wave of activity in developing solid-state lasers based on bulk Er3+-doped materials. The resonant pumping of SSL allows for shifting significant part of thermal load from gain medium itself to the pump diodes, thus greatly reducing gain medium thermal distortions deleterious to SSL power scaling with high beam quality. The two major resonant pumping bands in Er:YAG are centered around 1470 and 1532 nm. Pumping into each of these bands has its pros and contras. The best approach to resonant pumping of Er:YAG active media in terms of pump wavelength is yet to be determined. We report the investigation results of high power diode-pumped Er:YAG laser aimed at direct comparison of resonant pumping at 1470 and 1532 nm. Two sources used for pumping were: 1530-nm 10-diode bar stack (>300 W CW) and 1470-nm 10-diode bar stack (>650 W CW). Both pumps were spectrally narrowed by external volume Bragg gratings. The obtained spectral width of less than 1 nm allowed for 'in-line' pumping of Er3+ in either band. The obtained CW power of over 87 W is, to the best of our knowledge, the record high power reported for resonantly pumped Er:YAG DPSSL at room temperature.

  11. Types of Breast Pumps

    MedlinePlus

    ... nipple (the areola). b. Pump: creates the gentle vacuum that expresses milk. The pump may be attached to the breast-shield or ... out of a larger tube to create a vacuum that expresses milk and collects it in an attached container. Another type of manual pump, called a bicycle horn pump, consists of a ...

  12. Sex differences in circulatory oxygen transport parameters of sockeye salmon (Oncorhynchus nerka) on the spawning ground.

    PubMed

    Clark, Timothy Darren; Hinch, S G; Taylor, B D; Frappell, P B; Farrell, A P

    2009-07-01

    Upon reaching sexual maturity, several species of male salmonids possess a relative ventricular mass (rM(V)) that may be up to 90% larger than females. This can increase maximum cardiac stroke volume and power output, which may be beneficial to increasing the oxygen transport capacity of male salmonids during the spawning period. It may be further hypothesized, therefore, that other variables within the circulatory oxygen transport cascade, such as blood oxygen-carrying capacity and heart rate, are similarly enhanced in reproductively mature male salmonids. To test this idea, the present study measured a range of circulatory oxygen transport variables in wild male and female sockeye salmon (Oncorhynchus nerka) during their spawning period, following a 150 km migration from the ocean. The rM(V) of male fish was 13% greater than females. Conversely, the haemoglobin concentration ([Hb]) of female fish was 19% higher than males, indicative of a greater blood oxygen-carrying capacity (138 vs. 116 ml O2 l(-1), respectively). Surgically implanted physiological data loggers revealed a similar range in heart rate for both sexes on the spawning ground (20-80 beats min(-1) at 10 degrees C), with a tendency for male fish to spend a greater percentage of time (64%) than females (49%) at heart rates above 50 beats min(-1). Male fish on average consumed significantly more oxygen than females during a 13-h respirometry period. However, routine oxygen consumption rates (.)MO2 ranged between 1.5 and 8.5 mg min(-1) kg(-1) for both sexes, which implies that males did not inherently possess markedly higher routine aerobic energy demands, and suggests that the higher [Hb] of female fish may compensate for the smaller rM(V). These findings reject the hypothesis that all aspects of the circulatory oxygen transport cascade are inherently superior in male sockeye salmon. Instead, it is suggested that any differences in (.)MO2 between sexually mature male and female sockeye salmon can likely

  13. SHINE Vacuum Pump Test Verification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morgan, Gregg A; Peters, Brent

    2013-09-30

    Normetex pumps used world-wide for tritium service are no longer available. DOE and other researchers worldwide have spent significant funds characterizing this pump. Identification of alternate pumps is required for performance and compatibility with tritium gas. Many of the pumps that could be used to meet the functional performance requirements (e.g. pressure and flow conditions) of the Normetex pump have features that include the use of polymers or oils and greases that are not directly compatible with tritium service. This study assembles a test system to determine the flow characteristics for candidate alternate pumps. These tests are critical to themore » movement of tritium through the SHINE Tritium Purification System (TPS). The purpose of the pump testing is two-fold: (1) obtain baseline vacuum pump characteristics for an alternate (i.e. ''Normetex replacement'') pump intended for use in tritium service; and (2) verify that low pressure hydrogen gas can be transported over distances up to 300 feet by the candidate pumps. Flow rates and nominal system pressures have been identified for the SHINE Mo-99 production process Tritium Purification System (TPS). To minimize the line sizes for the transfer of low pressure tritium from the Neutron Driver Accelerator System (NDAS) to the primary processing systems in the TPS, a ''booster'' pump has been located near the accelerator in the design. A series of pump tests were performed at various configurations using hydrogen gas (no tritium) to ensure that this concept is practical and maintains adequate flow rates and required pressures. This report summarizes the results of the tests that have been performed using various pump configurations. The current design of the Tritium Purification System requires the ''booster'' pump to discharge to or to be backed by another vacuum pump. Since Normetex pumps are no longer manufactured, a commercially available Edwards scroll pump will be used to back the booster pump. In

  14. Normetex Pump Alternatives Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Clark, Elliot A.

    2013-04-25

    A mainstay pump for tritium systems, the Normetex scroll pump, is currently unavailable because the Normetex company went out of business. This pump was an all-metal scroll pump that served tritium processing facilities very well. Current tritium system operators are evaluating replacement pumps for the Normetex pump and for general used in tritium service. An all-metal equivalent alternative to the Normetex pump has not yet been identified. 1. The ideal replacement tritium pump would be hermetically sealed and contain no polymer components or oils. Polymers and oils degrade over time when they contact ionizing radiation. 2. Halogenated polymers (containing fluorine,more » chlorine, or both) and oils are commonly found in pumps. These materials have many properties that surpass those of hydrocarbon-based polymers and oils, including thermal stability (higher operating temperature) and better chemical resistance. Unfortunately, they are less resistant to degradation from ionizing radiation than hydrocarbon-based materials (in general). 3. Polymers and oils can form gaseous, condensable (HF, TF), liquid, and solid species when exposed to ionizing radiation. For example, halogenated polymers form HF and HCl, which are extremely corrosive upon reaction with water. If a pump containing polymers or oils must be used in a tritium system, the system must be designed to be able to process the unwanted by-products. Design features to mitigate degradation products include filters and chemical or physical traps (eg. cold traps, oil traps). 4. Polymer components can work in tritium systems, but must be replaced regularly. Polymer components performance should be monitored or be regularly tested, and regular replacement of components should be viewed as an expected normal event. A radioactive waste stream must be established to dispose of used polymer components and oil with an approved disposal plan developed based on the facility location and its regulators. Polymers have

  15. Review article: the functional abdominal pain syndrome.

    PubMed

    Sperber, A D; Drossman, D A

    2011-03-01

    Functional abdominal pain syndrome (FAPS) is a debilitating disorder with constant or nearly constant abdominal pain, present for at least 6 months and loss of daily functioning. To review the epidemiology, pathophysiology and treatment of FAPS. A literature review using the keywords: functional abdominal pain, chronic abdominal pain, irritable bowel syndrome and functional gastrointestinal disorders. No epidemiological studies have focused specifically on FAPS. Estimates of prevalence range from 0.5% to 1.7% and tend to show a female predominance. FAPS pathophysiology appears unique in that the pain is caused primarily by amplified central perception of normal visceral input, rather than by enhanced peripheral stimulation from abdominal viscera. The diagnosis of FAPS is symptom-based in accordance with the Rome III diagnostic criteria. These criteria are geared to identify patients with severe symptoms as they require constant or nearly constant abdominal pain with loss of daily function and are differentiated from IBS based on their non-association with changes in bowel habit, eating or other gut-related events. As cure is not feasible, the aims of treatment are reduced suffering and improved quality of life. Treatment is based on a biopsychosocial approach with a therapeutic patient-physician partnership at its base. Therapeutic options include central nonpharmacological and pharmacological modalities and peripheral modalities. These can be combined to produce an augmentation effect. Although few studies have assessed functional abdominal pain syndrome or its treatment specifically, the treatment strategies outlined in this paper appear to be effective. © 2011 Blackwell Publishing Ltd.

  16. Causes and Consequences of Missing Health-Related Quality of Life Assessments in Patients Who Undergo Mechanical Circulatory Support Implantation: Insights From INTERMACS (Interagency Registry for Mechanically Assisted Circulatory Support).

    PubMed

    Grady, Kathleen L; Jones, Philip G; Cristian-Andrei, Adin; Naftel, David C; Myers, Susan; Dew, Mary Amanda; Idrissi, Katharine; Weidner, Gerdi; Wissman, Sherri A; Kirklin, James K; Spertus, John A

    2017-12-01

    Missing health-related quality of life (HRQOL) data in longitudinal studies can reduce precision and power and bias results. Using INTERMACS (Interagency Registry for Mechanically Assisted Circulatory Support), we sought to identify factors associated with missing HRQOL data, examine the impact of these factors on estimated HRQOL assuming missing at random missingness, and perform sensitivity analyses to examine missing not at random (MNAR) missingness because of illness severity. INTERMACS patients (n=3248) with a preimplantation profile of 1 (critical cardiogenic shock) or 2 (progressive decline) were assessed with the EQ-5D-3L visual analog scale and Kansas City Cardiomyopathy Questionnaire-12 summary scores pre-implantation and 3 months postoperatively. Mean and median observed and missing at random-imputed HRQOL scores were calculated, followed by sensitivity analyses. Independent factors associated with HRQOL scores and missing HRQOL assessments were determined using multivariable regression. Independent factors associated with preimplantation and 3-month HRQOL scores, and with the likelihood of missing HRQOL assessments, revealed few correlates of HRQOL and missing assessments ( R 2 range, 4.7%-11.9%). For patients with INTERMACS profiles 1 and 2 and INTERMACS profile 1 alone, missing at random-imputed mean and median HRQOL scores were similar to observed scores, before and 3 months after implantation, whereas MNAR-imputed mean scores were lower (≥5 points) at baseline but not at 3 months. We recommend use of sensitivity analyses using an MNAR imputation strategy for longitudinal studies when missingness is attributable to illness severity. Conduct of MNAR sensitivity analyses may be less critical after mechanical circulatory support implant, when there are likely fewer MNAR data. © 2017 American Heart Association, Inc.

  17. Medical evacuation for unrecognized abdominal wall pain: a case series.

    PubMed

    Msonda, Hapu T; Laczek, Jeffrey T

    2015-05-01

    Chronic abdominal pain is a frequently encountered complaint in the primary care setting. The abdominal wall is the etiology of this pain in 10 to 30% of all cases of chronic abdominal pain. Abdominal cutaneous nerve entrapment at the lateral border of the rectus abdominis muscle has been attributed as a cause of this pain. In the military health care system, patients with unexplained abdominal pain are often transferred to military treatment facilities via the Military Medical Evacuation (MEDEVAC) system. We present two cases of patients who transferred via MEDEVAC to our facility for evaluation and treatment of chronic abdominal pain. Both patients had previously undergone extensive laboratory evaluation, imaging, and invasive procedures, such as esophagogastroduodenoscopy before transfer. Upon arrival, history and physical examinations suggested an abdominal wall source to their pain, and both patients experienced alleviation of their abdominal wall pain with lidocaine and corticosteroid injection. This case series highlights the need for military physicians to be aware of abdominal wall pain. Early diagnosis of abdominal cutaneous nerve entrapment syndrome by eliciting Carnett's sign will limit symptom chronicity, avoid unnecessary testing, and even prevent medical evacuation. Reprint & Copyright © 2015 Association of Military Surgeons of the U.S.

  18. 11. PUMP HOUSE AND WEIGHING ROOM Fish were pumped from ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    11. PUMP HOUSE AND WEIGHING ROOM Fish were pumped from floating hoppers, to the pump house (on the far right). From there they were either lifted by conveyor belt to the weighing room (top center) and thence to the holding tanks, or were washed through sealers, weighed and then sluiced to holding tanks. The process used depended upon the type and size of fish. The square cement vat (center) was to be a settling tank from which fish oil, reclaimed from the reduction process, was to be pumped into the round metal tank (above the vat). This process however, was never fully utilized before the sardines ran out. - Hovden Cannery, 886 Cannery Row, Monterey, Monterey County, CA

  19. Congenital heart disease manifested as acute abdominal pain.

    PubMed

    Macha, Mahender; Gupta, Dipin; Molina, Ezequiel; Palma, Jon; Rothman, Steven

    2007-06-12

    We present a case of a 53-year-old man with complaints of severe abdominal pain and nausea. Emergency department abdominal workup was non-diagnostic. Physical examination revealed signs of right- and left-heart failure. A past medical history of dysrhythmias and chronic abdominal complaints prompted hospital admission. Subsequent right heart catheterization revealed a significant left-to-right shunt. CT scan of the chest and angiography confirmed the diagnosis of an abnormal ascending vein between the innominate vein and the left superior pulmonary vein. After the anomalous vein was ligated, the patient's abdominal pain resolved.

  20. Simultaneous repair of abdominal aortic aneurysm and resection of unexpected, associated abdominal malignancies.

    PubMed

    Illuminati, Giulio; Calio', Francesco G; D'Urso, Antonio; Lorusso, Riccardo; Ceccanei, Gianluca; Vietri, Francesco

    2004-12-15

    The management of unexpected intra-abdominal malignancy, discovered at laparotomy for elective treatment of an abdominal aortic aneurysm (AAA), is controversial. It is still unclear whether both conditions should be treated simultaneously or a staged approach is to be preferred. To contribute in improving treatment guidelines, we retrospectively reviewed the records of patients undergoing laparotomy for elective AAA repair. From January 1994 to March 2003, 253 patients underwent elective, trans-peritoneal repair of an AAA. In four patients (1.6%), an associated, unexpected neoplasm was detected at abdominal exploration, consisting of one renal, one gastric, one ileal carcinoid, and one ascending colon tumor. All of them were treated at the same operation, after aortic repair and careful isolation of the prosthetic graft. The whole series' operative mortality was 3.6%. None of the patients simultaneously treated for AAA and tumor resection died in the postoperative period. No graft-related infections were observed. Simultaneous treatment of AAA and tumor did not prolong significantly the mean length of stay in the hospital, compared to standard treatment of AAA alone. Except for malignancies of organs requiring major surgical resections, simultaneous AAA repair and resection of an associated, unexpected abdominal neoplasm can be safely performed, in most of the patients, sparing the need for a second procedure. Endovascular grafting of the AAA can be a valuable tool in simplifying simultaneous treatment, or in staging the procedures with a very short delay.

  1. Responses of intra-abdominal pressure and abdominal muscle activity during dynamic trunk loading in man.

    PubMed

    Cresswell, A G

    1993-01-01

    The purpose of this study was to determine and compare interactions between the abdominal musculature and intra-abdominal pressure (IAP) during controlled dynamic and static trunk muscle loading. Myoelectric activity was recorded in six subjects from the rectus abdominis, obliquus externus, obliquus internus, transversus abdominis and erector spinae muscles using surface and intra-muscular fine-wire electrodes. The IAP was recorded intra-gastrically. Trunk flexions and extensions were performed lying on one side on a swivel table. An adjustable brake provided different friction loading conditions, while adding weights to an unbraked swivel table afforded various levels of inertial loading. During trunk extensions at all friction loads, IAP was elevated (1.8-7.2 kPa) with concomitant activity in transversus abdominis and obliquus internus muscles--little or no activity was seen from rectus abdominis and obliquus externus muscles. For inertia loading during trunk extension, IAP levels were somewhat lower (1.8-5.6 kPa) and displayed a second peak when abdominal muscle activity occurred in the course of decelerating the movement. For single trunk flexions with friction loading, IAP was higher than that seen in extension conditions and increased with added resistance. For inertial loading during trunk flexion, IAP showed two peaks, the larger first peak matched peak forward acceleration and general abdominal muscle activation, while the second corresponded to peak deceleration and was accompanied by activity in transversus abdominis and erector spinae muscles. It was apparent that different loading strategies produced markedly different patterns of response in both trunk musculature and intra-abdominal pressure.

  2. Rotary Blood Pump

    NASA Technical Reports Server (NTRS)

    Bozeman, Richard J., Jr. (Inventor); Akkerman, James W. (Inventor); Aber, Gregory S. (Inventor); VanDamm, George A. (Inventor); Bacak, James W. (Inventor); Svejkovsky, Paul A. (Inventor); Benkowski, Robert J. (Inventor)

    1996-01-01

    A rotary blood pump includes a pump housing for receiving a flow straightener, a rotor mounted on rotor bearings and having an inducer portion and an impeller portion, and a diffuser. The entrance angle, outlet angle, axial and radial clearances of blades associated with the flow straightener, inducer portion, impeller portion and diffuser are optimized to minimize hemolysis while maintaining pump efficiency. The rotor bearing includes a bearing chamber that is filled with cross-linked blood or other bio-compatible material. A back emf integrated circuit regulates rotor operation and a microcomputer may be used to control one or more back emf integrated circuits. A plurality of magnets are disposed in each of a plurality of impeller blades with a small air gap. A stator may be axially adjusted on the pump housing to absorb bearing load and maximize pump efficiency.

  3. Prophylactic antibiotics for penetrating abdominal trauma.

    PubMed

    Brand, Martin; Grieve, Andrew

    2013-11-18

    Penetrating abdominal trauma occurs when the peritoneal cavity is breached. Routine laparotomy for penetrating abdominal injuries began in the 1800s, with antibiotics first being used in World War II to combat septic complications associated with these injuries. This practice was marked with a reduction in sepsis-related mortality and morbidity. Whether prophylactic antibiotics are required in the prevention of infective complications following penetrating abdominal trauma is controversial, however, as no randomised placebo controlled trials have been published to date. There has also been debate about the timing of antibiotic prophylaxis. In 1972 Fullen noted a 7% to 11% post-surgical infection rate with pre-operative antibiotics, a 33% to 57% infection rate with intra-operative antibiotic administration and 30% to 70% infection rate with only post-operative antibiotic administration. Current guidelines state there is sufficient class I evidence to support the use of a single pre-operative broad spectrum antibiotic dose, with aerobic and anaerobic cover, and continuation (up to 24 hours) only in the event of a hollow viscus perforation found at exploratory laparotomy. To assess the benefits and harms of prophylactic antibiotics administered for penetrating abdominal injuries for the reduction of the incidence of septic complications, such as septicaemia, intra-abdominal abscesses and wound infections. Searches were not restricted by date, language or publication status. We searched the following electronic databases: the Cochrane Injuries Group Specialised Register, CENTRAL (The Cochrane Library 2013, issue 12 of 12), MEDLINE (OvidSP), Embase (OvidSP), ISI Web of Science: Science Citation Index Expanded (SCI-EXPANDED), ISI Web of Science: Conference Proceedings Citation Index- Science (CPCI-S) and PubMed. Searches were last conducted in January 2013. All randomised controlled trials of antibiotic prophylaxis in patients with penetrating abdominal trauma versus no

  4. How useful is abdominal ultrasonography in dogs with diarrhoea?

    PubMed

    Mapletoft, E K; Allenspach, K; Lamb, C R

    2018-01-01

    To assess the utility of abdominal ultrasonography in the diagnostic work-up of dogs with diarrhoea. Retrospective cross-sectional study based on a referral population of dogs with diarrhoea. Associations between the clinical signs, use of abdominal ultrasonography, results of abdominal ultrasonography and subsequent work-up were examined. The utility of abdominal ultrasonography was scored as high, moderate, none or counterproductive based on review of medical records. Medical records of 269 dogs were reviewed, of which 149 (55%) had abdominal ultrasonography. The most frequent result was no ultrasonographic abnormalities affecting the intestine in 65 (44%) dogs. Ultrasonography results were associated with subsequent work-up as follows: (1) no detected abnormalities and dietary trial; (2) focal thickening of the intestinal wall, loss of intestinal wall layers or enlarged abdominal lymph nodes and ultrasound-guided fine-needle aspirates; (3) diffuse thickening of the intestinal wall or hyperechoic striations in the small intestinal mucosa and endoscopy; and (4) small intestinal foreign body and coeliotomy. Abdominal ultrasonography was considered to be diagnostic without further testing in only four (3%) dogs: two had a portosystemic shunt identified ultrasonographically, one had a linear foreign body and one had a perforated pyloric ulcer. Abdominal ultrasonography had moderate utility in 56 (38%) dogs and no utility in 79 (53%) dogs. Abdominal ultrasonography was considered counterproductive in 10 (7%) dogs because results were either falsely negative or falsely positive. These results should prompt clinicians to reconsider routine use of abdominal ultrasonography in dogs with diarrhoea. © 2017 British Small Animal Veterinary Association.

  5. Somatization symptoms in pediatric abdominal pain patients: relation to chronicity of abdominal pain and parent somatization.

    PubMed

    Walker, L S; Garber, J; Greene, J W

    1991-08-01

    Symptoms of somatization were investigated in pediatric patients with recurrent abdominal pain (RAP) and comparison groups of patients with organic etiology for abdominal pain and well patients. Somatization scores were higher in RAP patients than well patients at the clinic visit, and higher than in either well patients or organic patients at a 3-month followup. Higher somatization scores in mothers and fathers were associated with higher somatization scores in RAP patients, but not in organic or well patients. Contrary to the findings of Ernst, Routh, and Harper (1984), chronicity of abdominal pain in RAP patients was not significantly associated with their level of somatization symptoms. Psychometric information about the Children's Somatization Inventory is presented.

  6. A pump monitoring approach to irrigation pumping plant testing

    USDA-ARS?s Scientific Manuscript database

    The conventional approach for evaluating irrigation pumping plant performance has been an instantaneous spot measurement approach. Using this method, the tester measures the necessary work and energy use parameters to determine overall pumping plant performance. The primary limitation of this appr...

  7. Abdominal injuries in communal crises: The Jos experience

    PubMed Central

    Ojo, Emmanuel Olorundare; Ozoilo, Kenneth N.; Sule, Augustine Z.; Ugwu, Benjamin T.; Misauno, Michael A.; Ismaila, Bashiru O.; Peter, Solomon D.; Adejumo, Adeyinka A.

    2016-01-01

    Background: Abdominal injuries contribute significantly to battlefield trauma morbidity and mortality. This study sought to determine the incidence, demographics, clinical features, spectrum, severity, management, and outcome of abdominal trauma during a civilian conflict. Materials and Methods: A prospective analysis of patients treated for abdominal trauma during the Jos civil crises between December 2010 and May 2012 at the Jos University Teaching Hospital. Results: A total of 109 victims of communal conflicts with abdominal injuries were managed during the study period with 89 (81.7%) males and 20 (18.3%) females representing about 12.2% of the total 897 combat related injuries. The peak age incidence was between 21 and 40 years (range: 3–71 years). The most frequently injured intra-abdominal organs were the small intestine 69 (63.3%), colon 48 (44%), and liver 41 (37.6%). Forty-four (40.4%) patients had extra-abdominal injuries involving the chest in 17 (15.6%), musculoskeletal 12 (11%), and the head in 9 (8.3%). The most prevalent weapon injuries were gunshot 76 (69.7%), explosives 12 (11%), stab injuries 11 (10.1%), and blunt abdominal trauma 10 (9.2%). The injury severity score varied from 8 to 52 (mean: 20.8) with a fatality rate of 11 (10.1%) and morbidity rate of 29 (26.6%). Presence of irreversible shock, 3 or more injured intra-abdominal organs, severe head injuries, and delayed presentation were the main factors associated with mortality. Conclusion: Abdominal trauma is major life-threatening injuries during conflicts. Substantial mortality occurred with loss of nearly one in every 10 hospitalized victims despite aggressive emergency room resuscitation. The resources expenditure, propensity for death and expediency of timing reinforce the need for early access to the wounded in a concerted trauma care systems. PMID:26957819

  8. Improvement of centrifugal pump performance through addition of splitter blades on impeller pump

    NASA Astrophysics Data System (ADS)

    Kurniawan, Krisna Eka; Santoso, Budi; Tjahjana, Dominicus Danardono Dwi Prija

    2018-02-01

    The workable way to improve pump performance is to redesign or modify the impellers of centrifugal pump. The purpose of impeller pump modification is to improve pump efficiency, reduce cross flow, reduce secondary incidence flows, and decrease backflow areas at impeller outlets. Number blades and splitter blades in the impeller are three. The outlet blade angle is 20°, and the rotating speed of impeller is 2400 rpm. The added splitter blades variations are 0.25, 0.375, and 0.5 of the original blade length. The splitter blade placements are on the outer side of the impeller. The addition of splitter blades on the outer side of the impeller with 0.5L increases the pump head until 22% and the pump has 38.66% hydraulic efficiency. The best efficiency point of water flow rate pump (Qbep) was 3.02 × 10-3 m3/s.

  9. Early outcomes of on-pump versus off-pump coronary artery bypass grafting.

    PubMed

    Hussain, Ghulam; Azam, Hammad; Baig, Mirza Ahmad Raza; Ahmad, Naseem

    2016-01-01

    To see the early post-operative outcomes of off-pump versus on-pump coronary artery bypass graft surgery. This retrospective analytical study was conducted at Ch. Pervaiz Elahi Institute of Cardiology Multan, Pakistan. Our Primary outcome variables were; necessity of inotropic support, nonfatal myocardial infarction, ICU stay, nonfatal stroke, new renal failure requiring dialysis and death within 30 days after operation. There were two groups of patients; Group-I (On-pump group) and Group-II (Off-pump Group). SPSS V17 was used for data analysis. Independent sample t-test and Mann Whitney U test were used to compare quantitative Variables. Chi-square test and Fisher's exact test were used to analyze qualitative variables. P-value ≤ 0.05 was considered significant. Three hundred patients were included in this study. There were no significant difference regarding risk factors except hyper-cholestrolemia which was high in off pump group (p-value 0.05). Angiographic and Echocardiographic characteristics e.g. preoperative ejection fraction, LV function grade and severity of CAD was same between the groups. Mortality risk scores and Priority status for surgery were also same. Regarding post-operative outcomes; Post-op CKMB Levels, need and duration of inotropic support, mechanical ventilation time and ICU stay was significantly less in Off-Pump group (p-value 0.001, <0.0001, 0.006, 0.025 and 0.001 resp.). Peri-operative chest drainage was significantly high in On-pump CABG group (p-value 0.027). Incidence of post-op complications was not statistically different between the groups. At 30 days follow-up, Incidence of myocardial infarction, necessity and duration of inotropic support, ICU stay period and peri-operative bleeding were significantly less in off-pump group. The incidence of neurologic, pulmonary and renal complications was same between the off-pump and on-pump groups.

  10. Early outcomes of on-pump versus off-pump coronary artery bypass grafting

    PubMed Central

    Hussain, Ghulam; Azam, Hammad; Baig, Mirza Ahmad Raza; Ahmad, Naseem

    2016-01-01

    Objectives: To see the early post-operative outcomes of off-pump versus on-pump coronary artery bypass graft surgery. Methods: This retrospective analytical study was conducted at Ch. Pervaiz Elahi Institute of Cardiology Multan, Pakistan. Our Primary outcome variables were; necessity of inotropic support, nonfatal myocardial infarction, ICU stay, nonfatal stroke, new renal failure requiring dialysis and death within 30 days after operation. There were two groups of patients; Group-I (On-pump group) and Group-II (Off-pump Group). SPSS V17 was used for data analysis. Independent sample t-test and Mann Whitney U test were used to compare quantitative Variables. Chi-square test and Fisher’s exact test were used to analyze qualitative variables. P-value ≤ 0.05 was considered significant. Results: Three hundred patients were included in this study. There were no significant difference regarding risk factors except hyper-cholestrolemia which was high in off pump group (p-value 0.05). Angiographic and Echocardiographic characteristics e.g. preoperative ejection fraction, LV function grade and severity of CAD was same between the groups. Mortality risk scores and Priority status for surgery were also same. Regarding post-operative outcomes; Post-op CKMB Levels, need and duration of inotropic support, mechanical ventilation time and ICU stay was significantly less in Off-Pump group (p-value 0.001, <0.0001, 0.006, 0.025 and 0.001 resp.). Peri-operative chest drainage was significantly high in On-pump CABG group (p-value 0.027). Incidence of post-op complications was not statistically different between the groups. Conclusions: At 30 days follow-up, Incidence of myocardial infarction, necessity and duration of inotropic support, ICU stay period and peri-operative bleeding were significantly less in off-pump group. The incidence of neurologic, pulmonary and renal complications was same between the off-pump and on-pump groups. PMID:27648039

  11. Risk Assessment of Abdominal Wall Thickness Measured on Pre-Operative Computerized Tomography for Incisional Surgical Site Infection after Abdominal Surgery.

    PubMed

    Tongyoo, Assanee; Chatthamrak, Putipan; Sriussadaporn, Ekkapak; Limpavitayaporn, Palin; Mingmalairak, Chatchai

    2015-07-01

    The surgical site infection (SSI) is a common complication of abdominal operation. It relates to increased hospital stay, increased healthcare cost, and decreased patient's quality of life. Obesity, usually defined by BMI, is known as one of the risks of SSI. However, the thickness of subcutaneous layers of abdominal wall might be an important local factor affecting the rate of SSI after the abdominal operations. The objective of this study is to assess the importance of the abdominal wall thickness on incisional SSI rate. The subjects of the present study were patients who had undergone major abdominal operations at Thammasat University Hospital between June 2013 and May 2014, and had been investigated with CT scans before their operations. The demographic data and clinical information of these patients were recorded. The thickness ofsubcutaneous fatty tissue from skin down to the most superficial layer of abdominal wall muscle at the surgical site was measured on CT images. The wound infectious complication was reviewed and categorized as superficial and deep incisional SSIfollowing the definition from Centersfor Disease Control and Prevention (CDC) guidelines. The significance ofeach potentialfactors on SSI rates was determined separately with student t-test for quantitative data and χ2-test for categorical data. Then all factors, which had p < 0.10, were included into the multivariate logistic regression analysis and were analyzed with significance at p < 0.05. One hundred and thirty-nine patients were included in this study. They all underwent major abdominal surgery and had had pre-operative CTscans. Post-operative SSI was 25.2% (35/139), superficial and deep types in 27 and 8 patients, respectively. The comparison of abdominal wall thickness between patients with and without infection was significantly different (20.0 ± 8.4 mm and 16.0 ± 7.2 mm, respectively). When the thickness at 20 mm was used as the cut-off value, 43 of 139 patients had abdominal wall

  12. Fuel pumping system and method

    DOEpatents

    Shafer, Scott F [Morton, IL; Wang, Lifeng ,

    2006-12-19

    A fuel pumping system that includes a pump drive is provided. A first pumping element is operatively connected to the pump drive and is operable to generate a first flow of pressurized fuel. A second pumping element is operatively connected to the pump drive and is operable to generate a second flow of pressurized fuel. A first solenoid is operatively connected to the first pumping element and is operable to vary at least one of a fuel pressure and a fuel flow rate of the first flow of pressurized fuel. A second solenoid is operatively connected to the second pumping element and is operable to vary at least one of a fuel pressure and a fuel flow rate of the second flow of pressurized fuel.

  13. Fuel Pumping System And Method

    DOEpatents

    Shafer, Scott F.; Wang, Lifeng

    2005-12-13

    A fuel pumping system that includes a pump drive is provided. A first pumping element is operatively connected to the pump drive and is operable to generate a first flow of pressurized fuel. A second pumping element is operatively connected to the pump drive and is operable to generate a second flow of pressurized fuel. A first solenoid is operatively connected to the first pumping element and is operable to vary at least one of a fuel pressure and a fuel flow rate of the first flow of pressurized fuel. A second solenoid is operatively connected to the second pumping element and is operable to vary at least one of a fuel pressure and a fuel flow rate of the second flow of pressurized fuel.

  14. A single center's conversion from roller pump to centrifugal pump technology in extracorporeal membrane oxygenation.

    PubMed

    Shade, Brandon C; Schiavo, Kellie; Rosenthal, Tami; Connelly, James T; Melchior, Richard W

    2016-06-05

    Recent advances in blood pump technology have led to an increased use of centrifugal pumps for prolonged extracorporeal membrane oxygenation (ECMO). Data from the Extracorporeal Life Support Organization confirms that many institutions have converted to centrifugal pumps after prior experience with roller pump technology. Centrifugal pump technology is more compact and may generate less heat and hemolysis than a conventional roller pump. Based on the potential advantages of centrifugal pumps, a decision was made institution-wide to convert to centrifugal pump technology in pediatric implementation of ECMO. Based on limited prior experience with centrifugal pumps, a multidisciplinary approach was used to implement this new technology. The new centrifugal pump (Sorin Revolution, Arvada, CO) was intended for ECMO support in the cardiac intensive care unit (CICU), the pediatric intensive care unit (PICU) and the neonatal intensive care unit (NICU). The perfusion team used their knowledge and expertise with centrifugal pumps to create the necessary teaching tools and interactive training sessions for the technical specialists who consisted primarily of registered nurses and respiratory therapists. The first phase consisted of educating all personnel involved in the care of the ECMO patient, followed by patient implementation in the CICU, followed by the PICU and NICU. The institution-wide conversion took several months to complete and was well received among all disciplines in the CICU and PICU. The NICU personnel did use the centrifugal pump circuit, but decided to revert back to using the roller pump technology. A systematic transition from roller pump to centrifugal pump technology with a multidisciplinary team can ensure a safe and successful implementation. © The Author(s) 2016.

  15. Submersible sodium pump

    DOEpatents

    Brynsvold, Glen V.; Lopez, John T.; Olich, Eugene E.; West, Calvin W.

    1989-01-01

    An electromagnetic submerged pump has an outer cylindrical stator with an inner cylindrical conductive core for the submerged pumping of sodium in the cylindrical interstitial volume defined between the stator and core. The cylindrical interstitial volume is typically vertically oriented, and defines an inlet at the bottom and an outlet at the top. The outer stator generates upwardly conveyed toroidal magnetic fields, which fields convey preferably from the bottom of the pump to the top of the pump liquid sodium in the cold leg of a sodium cooled nuclear reactor. The outer cylindrical stator has a vertically disposed duct surrounded by alternately stacked layers of coil units and laminates.

  16. Submersible sodium pump

    DOEpatents

    Brynsvold, G.V.; Lopez, J.T.; Olich, E.E.; West, C.W.

    1989-11-21

    An electromagnetic submerged pump has an outer cylindrical stator with an inner cylindrical conductive core for the submerged pumping of sodium in the cylindrical interstitial volume defined between the stator and core. The cylindrical interstitial volume is typically vertically oriented, and defines an inlet at the bottom and an outlet at the top. The outer stator generates upwardly conveyed toroidal magnetic fields, which fields convey preferably from the bottom of the pump to the top of the pump liquid sodium in the cold leg of a sodium cooled nuclear reactor. The outer cylindrical stator has a vertically disposed duct surrounded by alternately stacked layers of coil units and laminates. 14 figs.

  17. Liquid metal electric pump

    DOEpatents

    Abbin, J.P.; Andraka, C.E.; Lukens, L.L.; Moreno, J.B.

    1992-01-14

    An electrical pump for pumping liquid metals to high pressures in high temperature environments without the use of magnets or moving mechanical parts. The pump employs a non-porous solid electrolyte membrane, typically ceramic, specific to the liquid metal to be pumped. A DC voltage is applied across the thickness of the membrane causing ions to form and enter the membrane on the electrically positive surface, with the ions being neutralized on the opposite surface. This action provides pumping of the liquid metal from one side of the non-porous solid electrolyte membrane to the other. 3 figs.

  18. Liquid metal electric pump

    DOEpatents

    Abbin, Joseph P.; Andraka, Charles E.; Lukens, Laurance L.; Moreno, James B.

    1992-01-01

    An electrical pump for pumping liquid metals to high pressures in high temperature environments without the use of magnets or moving mechanical parts. The pump employs a non-porous solid electrolyte membrane, typically ceramic, specific to the liquid metal to be pumped. A DC voltage is applied across the thickness of the membrane causing ions to form and enter the membrane on the electrically positive surface, with the ions being neutralized on the opposite surface. This action provides pumping of the liquid metal from one side of the non-porous solid electrolyte membrane to the other.

  19. Predictors of abdominal injuries in blunt trauma.

    PubMed

    Farrath, Samiris; Parreira, José Gustavo; Perlingeiro, Jacqueline A G; Solda, Silvia C; Assef, José Cesar

    2012-01-01

    To identify predictors of abdominal injuries in victims of blunt trauma. retrospective analysis of trauma protocols (collected prospectively) of adult victims of blunt trauma in a period of 15 months. Variables were compared between patients with abdominal injuries (AIS>0) detected by computed tomography or/and laparotomy (group I) and others (AIS=0, group II). Student's t, Fisher and qui-square tests were used for statistical analysis, considering p<0.05 as significant. A total of 3783 cases were included, with a mean age of 39.1 ± 17.7 years (14-99), 76.1% being male. Abdominal injuries were detected in 130 patients (3.4%). Patients sustaining abdominal injuries had significantly lower mean age (35.4 + 15.4 vs. 39.2 + 17.7), lower mean systolic blood pressure on admission (114.7 + 32.4 mmHg vs. 129.1 + 21.7 mmHg), lower mean Glasgow coma scale (12.9 + 3.9 vs. 14.3 + 2.0), as well as higher head AIS (0.95 + 1.5 vs. 0.67 + 1.1), higher thorax AIS (1.10 + 1.5 vs. 0.11 + 0.6) and higher extremities AIS (1.70 ± 1.8 vs. 1.03 ± 1.2). Patients sustaining abdominal injuries also presented higher frequency of severe injuries (AIS>3) in head (18.5% vs. 7.9%), thorax (29.2% vs. 2.4%) and extremities (40.0% vs. 13.7%). The highest odds ratios for the diagnosis of abdominal injuries were associated flail chest (21.8) and pelvic fractures (21.0). Abdominal injuries were more frequently observed in patients with hemodynamic instability, changes in Glasgow coma scale and severe lesions to the head, chest and extremities.

  20. Validity and reliability of the abdominal test and evaluation systems tool (ABTEST) to accurately measure abdominal force.

    PubMed

    Glenn, Jordan M; Galey, Madeline; Edwards, Abigail; Rickert, Bradley; Washington, Tyrone A

    2015-07-01

    Ability to generate force from the core musculature is a critical factor for sports and general activities with insufficiencies predisposing individuals to injury. This study evaluated isometric force production as a valid and reliable method of assessing abdominal force using the abdominal test and evaluation systems tool (ABTEST). Secondary analysis estimated 1-repetition maximum on commercially available abdominal machine compared to maximum force and average power on ABTEST system. This study utilized test-retest reliability and comparative analysis for validity. Reliability was measured using test-retest design on ABTEST. Validity was measured via comparison to estimated 1-repetition maximum on a commercially available abdominal device. Participants applied isometric, abdominal force against a transducer and muscular activation was evaluated measuring normalized electromyographic activity at the rectus-abdominus, rectus-femoris, and erector-spinae. Test, re-test force production on ABTEST was significantly correlated (r=0.84; p<0.001). Mean electromyographic activity for the rectus-abdominus (72.93% and 75.66%), rectus-femoris (6.59% and 6.51%), and erector-spinae (6.82% and 5.48%) were observed for trial-1 and trial-2, respectively. Significant correlations for the estimated 1-repetition maximum were found for average power (r=0.70, p=0.002) and maximum force (r=0.72, p<0.001). Data indicate the ABTEST can accurately measure rectus-abdominus force isolated from hip-flexor involvement. Negligible activation of erector-spinae substantiates little subjective effort among participants in the lower back. Results suggest ABTEST is a valid and reliable method of evaluating abdominal force. Copyright © 2014 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  1. Geothermal Heat Pump Basics | NREL

    Science.gov Websites

    a free source of hot water. Geothermal heat pumps use much less energy than conventional heating resources: Geothermal Heat Pumps U.S. Department of Energy's Office of Energy Efficiency and Renewable Heat Pump Basics Geothermal Heat Pump Basics Geothermal heat pumps take advantage of the nearly

  2. Post ventriculoperitoneal shunt abdominal pseudocyst: Challenges posed in management.

    PubMed

    Hamid, Raashid; Baba, Aejaz A; Bhat, Nisar A; Mufti, Gowhar; Mir, Younis A; Sajad, Wani

    2017-01-01

    In patients with hydrocephalus, the abdominal cavity has been used for absorption of cerebrospinal fluid (CSF) since 1905. Ventriculoperitoneal (VP) shunt operation is followed by abdominal complications in about 5-47% cases. Abdominal CSF pseudo cyst is an uncommon, but well described complication. This survey was conducted to study the clinical profile and management of this entity. We present our experience with cases of CSF pseudo cyst in children. Retrospective analysis of 4 cases diagnosed to have abdominal pseudo cyst following VP shunt between 2008 and 2013. All the four cases were suspected clinically and diagnosis was confirmed by abdominal ultrasonography. In three patients, the cyst was multilocular and of varying size. Fourth one had a unilocular cyst at the lower end of VP shunt. All the four patients had features of varying degree raised intracranial pressure and a two patients had abdominal signs also. All the patients needed open exploration. Cyst fluid was drained and partial to complete excision of the cyst was done along with the repositioning of the shunt in abdominal cavity in three patients and exteriorization of shunt in one patient. Patients were followed for any further complication over a period of 1-year. Abdominal pseudo cyst is a rare complication after VP Shunt and could result in shunt malfunction or abdominal symptoms and signs. Whenever suspected it should be confirmed by imaging, followed by open exploration and repositioning of the shunt.

  3. Post ventriculoperitoneal shunt abdominal pseudocyst: Challenges posed in management

    PubMed Central

    Hamid, Raashid; Baba, Aejaz A.; Bhat, Nisar A.; Mufti, Gowhar; Mir, Younis A.; Sajad, Wani

    2017-01-01

    Background: In patients with hydrocephalus, the abdominal cavity has been used for absorption of cerebrospinal fluid (CSF) since 1905. Ventriculoperitoneal (VP) shunt operation is followed by abdominal complications in about 5-47% cases. Abdominal CSF pseudo cyst is an uncommon, but well described complication. Aim: This survey was conducted to study the clinical profile and management of this entity. We present our experience with cases of CSF pseudo cyst in children. Materials and Methods: Retrospective analysis of 4 cases diagnosed to have abdominal pseudo cyst following VP shunt between 2008 and 2013. All the four cases were suspected clinically and diagnosis was confirmed by abdominal ultrasonography. Results: In three patients, the cyst was multilocular and of varying size. Fourth one had a unilocular cyst at the lower end of VP shunt. All the four patients had features of varying degree raised intracranial pressure and a two patients had abdominal signs also. All the patients needed open exploration. Cyst fluid was drained and partial to complete excision of the cyst was done along with the repositioning of the shunt in abdominal cavity in three patients and exteriorization of shunt in one patient. Patients were followed for any further complication over a period of 1-year. Conclusion: Abdominal pseudo cyst is a rare complication after VP Shunt and could result in shunt malfunction or abdominal symptoms and signs. Whenever suspected it should be confirmed by imaging, followed by open exploration and repositioning of the shunt. PMID:28413525

  4. Advanced high-temperature electromagnetic pump

    NASA Technical Reports Server (NTRS)

    Gahan, J. W.; Powell, A. H.

    1972-01-01

    Three phase helical, electromagnetic induction pump for use as boiler feed pump in potassium Rankine-cycle power system is described. Techniques for fabricating components of pump are discussed. Specifications of pump are analyzed.

  5. Unusual causes of abdominal pain: sickle cell anemia.

    PubMed

    Ahmed, Shahid; Shahid, Rabia K; Russo, Linda A

    2005-04-01

    Sickle cell disease is characterized by chronic hemolytic anemia and vaso-occlusive painful crises. The vascular occlusion in sickle cell disease is a complex process and accounts for the majority of the clinical manifestation of the disease. Abdominal pain is an important component of vaso-occlusive painful crises. It often represents a substantial diagnostic challenge in this population of patients. These episodes are often attributed to micro-vessel occlusion and infarcts of mesentery and abdominal viscera. Abdominal pain due to sickle cell vaso-occlusive crisis is often indistinguishable from an acute intra-abdominal disease process such as acute cholecystitis, acute pancreatitis, hepatic infarction, ischemic colitis and acute appendicitis. In the majority of cases, however, no specific cause is identified and spontaneous resolution occurs. This chapter will focus on etiologies, pathophysiology and management of abdominal pain in patients with sickle cell disease.

  6. Abdominal Tuberculosis in Cairo, Egypt

    DTIC Science & Technology

    1994-01-01

    COW 03 PUBLICATION REPORT 94-30227 * ABDOMINAL TUBERCULOSIS IN CAIRO, BY RWIavni 0. IHibbs6 M. Kuanmm ad Z. Fun .Y .~ ... W I Form ApprovedREPORT...Fever Hospital, Cairo, In the past, abdominal tuberculous ýileocaecal: was Egypt, are prospectively evaluated by the US Naval one of the commonest forms...8217. females of child-bearing age) indicated that 9 of 20 40%, were diagnosed as extrapulmonary tuberculosis. isolates from 91 tuberculous peritonitis

  7. Pump polarization insensitive and efficient laser-diode pumped Yb:KYW ultrafast oscillator.

    PubMed

    Wang, Sha; Wang, Yan-Biao; Feng, Guo-Ying; Zhou, Shou-Huan

    2016-02-01

    We theoretically and experimentally report and evaluate a novel split laser-diode (LD) double-end pumped Yb:KYW ultrafast oscillator aimed at improving the performance of an ultrafast laser. Compared to a conventional unpolarized single-LD end-pumped ultrafast laser system, we improve the laser performance such as absorption efficiency, slope efficiency, cw mode-locking threshold, and output power by this new structure LD-pumped Yb:KYW ultrafast laser. Experiments were carried out with a 1 W output fiber-coupled LD. Experimental results show that the absorption increases from 38.7% to 48.4%, laser slope efficiency increases from 18.3% to 24.2%, cw mode-locking threshold decreases 12.7% from 630 to 550 mW in cw mode-locking threshold, and maximum output-power increases 28.5% from 158.4 to 221.5 mW when we switch the pump scheme from an unpolarized single-end pumping structure to a split LD double-end pumping structure.

  8. Gas-heat-pump development

    NASA Astrophysics Data System (ADS)

    Creswick, F. A.

    Incentives for the development of gas heat pumps are discussed. Technical progress made on several promising technologies was reviewed. The status of development of gas-engine-driven heat pumps, the absorption cycle for the near- and long-term gas heat pump systems, the Stirling engine, the small Rankine-cycle engines, and gas-turbine-driven heat pump systems were briefly reviewed. Progress in the US, Japan, and Europe is noted.

  9. Abdominal CT scan

    MedlinePlus

    Computed tomography scan - abdomen; CT scan - abdomen; CT abdomen and pelvis ... An abdominal CT scan makes detailed pictures of the structures inside your belly very quickly. This test may be used to look ...

  10. Arnebia euchroma ointment can reduce abdominal fat thickness and abdominal circumference of overweight women: A randomized controlled study.

    PubMed

    Siavash, Mansour; Naseri, Mohsen; Rahimi, Mojgan

    2016-01-01

    Obesity is a worldwide health problem which is associated with a lot of complications. One of these comorbidities is the metabolic syndrome that is in correlation with abdominal fat thickness and waist circumference. Various methods were used to reduce abdominal fat thickness such as liposuction. A noninvasive method is the topical agent. In this study, we investigated the effectiveness of Arnebia euchroma (AE) ointment on the abdominal fat thickness. This study was a double-blind clinical trial which was done at the endocrinology clinic in Khorshid Hospital, Isfahan, Iran, in 2014. After explaining the procedure and obtaining informed consent, the candidates were randomly divided into the case and control groups. The participants of the case and control groups applied AE ointment or placebo for 6 weeks on their abdominal area. Body mass index, waist and buttock circumference, and abdominal fat thickness were measured in both case and control groups at their first visit and then at the next 2, 4, and 6 weeks. We used t -test for comparing parametric variables between groups, paired t -test for changes from baseline to final, and repeated measure ANOVA for changes at different steps. Sixty female candidates participated in this study (thirty in each group). Ten patients left the study and fifty participants finished the trial. At the end of the study, participants had a significant weight loss (2.96 ± 1.6 kg, P < 0.001) that was slightly more in the case group (3.15 ± 1.5 kg vs. 2.75 ± 1.7, P = 0.375). Abdominal circumference also decreased significantly in the participants (11.3 ± 6.7 cm, P < 0.001), but the changes were more significant in the case group (13.9 vs. 6.5 cm, P = 0.004). Similarly, abdominal fat thickness decreased significantly in the participants (2.3 ± 1.1 cm, P < 0.001), although changes were not significantly different between two groups (2.53 vs. 2.04 cm, P = 0.139). Topical AE ointment can reduce the abdominal fat thickness as well as the

  11. 2 kW pump-light-stripper-free distributed side-coupled cladding-pumped fiber oscillator

    NASA Astrophysics Data System (ADS)

    Ying, Hanyuan; Yu, Yu; Cao, Jianqiu; Huang, Zhihe; Pan, Zhiyong; Wang, Zefeng; Chen, Jinbao

    2017-06-01

    A 2 kW pump-light-stripper-free all-fiber distributed-pumping oscillator fabricated with the distributed side-coupled cladding-pumped Yb-doped fiber is demonstrated for the first time, to the best of our knowledge. An output power of 1969 W with a slope efficiency of 72.2% is obtained. By utilizing the final-section counter-pumping scheme, pure output spectra free from residual pump light are obtained without using any pump light stripper, which demonstrates that the pump light stripper is not indispensable for this configuration. Besides, no stimulated Raman scattering component is observed in the output spectra. The laser has the M 2 factor ranging from 2.0 to 2.6. We believe that the pertinent results are helpful and valuable for designing high-power fiber laser systems.

  12. The use of abdominal muscle training, breathing exercises and abdominal massage to treat paediatric chronic functional constipation.

    PubMed

    Silva, C A G; Motta, M E F A

    2013-05-01

    The effect of muscular training, abdominal massage and diaphragmatic breathing was compared with medical treatment in a prospective randomized trial of patients with chronic functional constipation. Patients aged 4-18 years old with functional constipation according to the Rome III criteria were randomized to physiotherapy or medical treatment. In the physiotherapy group, exercises (isometric training of the abdominal muscles, diaphragmatic breathing exercises and abdominal massage) were employed during 12 40-min sessions twice a week by a trained physiotherapist, with laxatives. Patients in the medication group were only given laxatives. Primary outcome measures were frequency of defaecation and faecal incontinence. The analysis was performed by intention-to-treat. After 6 weeks of treatment, the frequency of bowel movements was higher in the physiotherapy group [5.1 (2.1) days/week] than in the medication group [3.9 (2.0) days/week] (P = 0.01). The frequency of faecal incontinence was no different between the groups [3.6 (1.9) days/week vs 3.0 (2.1) days/week] (P = 0.31). The combined use of isometric training of abdominal muscles, breathing exercises and abdominal massage increased defaecation frequency after 6 weeks but faecal incontinence remained unchanged. Physiotherapy may be a useful treatment for constipation. Colorectal Disease © 2013 The Association of Coloproctology of Great Britain and Ireland.

  13. Developing seventh grade students' systems thinking skills in the context of the human circulatory system.

    PubMed

    Raved, Lena; Yarden, Anat

    2014-01-01

    Developing systems thinking skills in school can provide useful tools to deal with a vast amount of medical and health information that may help learners in decision making in their future lives as citizen. Thus, there is a need to develop effective tools that will allow learners to analyze biological systems and organize their knowledge. Here, we examine junior high school students' systems thinking skills in the context of the human circulatory system. A model was formulated for developing teaching and learning materials and for characterizing students' systems thinking skills. Specifically, we asked whether seventh grade students, who studied about the human circulatory system, acquired systems thinking skills, and what are the characteristics of those skills? Concept maps were used to characterize students' systems thinking components and examine possible changes in the students' knowledge structure. These maps were composed by the students before and following the learning process. The study findings indicate a significant improvement in the students' ability to recognize the system components and the processes that occur within the system, as well as the relationships between different levels of organization of the system, following the learning process. Thus, following learning students were able to organize the systems' components and its processes within a framework of relationships, namely the students' systems thinking skills were improved in the course of learning using the teaching and learning materials.

  14. Developing Seventh Grade Students’ Systems Thinking Skills in the Context of the Human Circulatory System

    PubMed Central

    Raved, Lena; Yarden, Anat

    2014-01-01

    Developing systems thinking skills in school can provide useful tools to deal with a vast amount of medical and health information that may help learners in decision making in their future lives as citizen. Thus, there is a need to develop effective tools that will allow learners to analyze biological systems and organize their knowledge. Here, we examine junior high school students’ systems thinking skills in the context of the human circulatory system. A model was formulated for developing teaching and learning materials and for characterizing students’ systems thinking skills. Specifically, we asked whether seventh grade students, who studied about the human circulatory system, acquired systems thinking skills, and what are the characteristics of those skills? Concept maps were used to characterize students’ systems thinking components and examine possible changes in the students’ knowledge structure. These maps were composed by the students before and following the learning process. The study findings indicate a significant improvement in the students’ ability to recognize the system components and the processes that occur within the system, as well as the relationships between different levels of organization of the system, following the learning process. Thus, following learning students were able to organize the systems’ components and its processes within a framework of relationships, namely the students’ systems thinking skills were improved in the course of learning using the teaching and learning materials. PMID:25520948

  15. Inhibitors of Proton Pumping

    PubMed Central

    Bisson, Mary A.

    1986-01-01

    Reported inhibitors of the Characean plasmalemma proton pump were tested for their ability to inhibit the passive H+ conductance which develops in Chara corallina Klein ex Willd. at high pH. Diethylstilbestrol inhibits the proton pump and the passive H+ conductance with about the same time course, at concentrations that have no effect on cytoplasmic streaming. N-Ethylmaleimide, a sulfhydryl reagent which is small and relatively nonpolar, also inhibits both pumping and passive conductance of H+. However, it also inhibits cytoplasmic streaming with about the same time course, and therefore could not be considered a specific ATPase inhibitor. p-Chloromercuribenzene sulfonate (PCMBS), a sulfhydryl reagent which is large and charged and hence less able to penetrate the membrane, does not inhibit pumping or conductance at low concentration. At high concentration, PCMBS sometimes inhibits pumping without affecting H+ conductance, but since streaming is also inhibited, the effect on the pump cannot be said to be specific. 1-Ethyl-3-(3-dimethylaminopropyl)carbodiimide, a water soluble carbodiimide, weakly inhibits both pump and conductance, apparently specifically. PMID:16664807

  16. Structural and functional characterization of the contractile aorta and associated hemocytes of the mosquito Anopheles gambiae.

    PubMed

    Sigle, Leah T; Hillyer, Julián F

    2018-06-22

    The primary pump of the circulatory system of insects is a dorsal vessel that traverses the length of the insect. The anterior portion, located in the head, neck and thorax, is the aorta, and the posterior portion, located in the abdomen, is the heart. Here, we characterize the structure and function of the aorta and conical chamber of the mosquito, Anopheles gambiae The aorta begins in the head with an excurrent opening located above the dorsal pharyngeal plate and ends at the thoraco-abdominal junction where it joins the conical chamber of the heart. The aorta lacks ostia, and based on the diameter of the vessel as well as the density and helical orientation of muscle, consists of three regions: the anterior aorta, the bulbous chamber, and the posterior aorta. The aorta contracts in the anterograde direction, but these contractions are independent of heart contractions and do not play a major role in hemolymph propulsion. Intravital imaging of the venous channels, the first abdominal segment and the neck revealed that hemolymph only travels through the aorta in the anterograde direction, and does so only during periods of anterograde heart flow. Furthermore, hemolymph only enters the thoraco-abdominal ostia of the conical chamber when the heart contracts in the retrograde direction, propelling this hemolymph to the posterior of the body. Finally, very few hemocytes associate with the aorta, and unlike what is seen in the periostial regions of the heart, infection does not induce the aggregation of hemocytes on the aorta. © 2018. Published by The Company of Biologists Ltd.

  17. Jet pump assisted artery

    NASA Technical Reports Server (NTRS)

    1975-01-01

    A procedure for priming an arterial heat pump is reported; the procedure also has a means for maintaining the pump in a primed state. This concept utilizes a capillary driven jet pump to create the necessary suction to fill the artery. Basically, the jet pump consists of a venturi or nozzle-diffuser type constriction in the vapor passage. The throat of this venturi is connected to the artery. Thus vapor, gas, liquid, or a combination of the above is pumped continuously out of the artery. As a result, the artery is always filled with liquid and an adequate supply of working fluid is provided to the evaporator of the heat pipe.

  18. Teaching Integrative Physiology Using the Quantitative Circulatory Physiology Model and Case Discussion Method: Evaluation of the Learning Experience

    ERIC Educational Resources Information Center

    Rodriguez-Barbero, A.; Lopez-Novoa, J. M.

    2008-01-01

    One of the problems that we have found when teaching human physiology in a Spanish medical school is that the degree of understanding by the students of the integration between organs and systems is rather poor. We attempted to remedy this problem by using a case discussion method together with the Quantitative Circulatory Physiology (QCP)…

  19. Abdominal aortic aneurysm

    MedlinePlus

    ... this problem include: Smoking High blood pressure Male gender Genetic factors An abdominal aortic aneurysm is most ... body from an aortic aneurysm, you will need surgery right away. If the aneurysm is small and ...

  20. Abdominal Pain Syndrome

    MedlinePlus

    ... blood clots to the lungs) Abdominal or chest wall pain: Shingles (herpes zoster infection) Costochondritis (inflammation of ... or tumors), fat (evidence of impaired digestion and absorption of food), and the presence of germs. X- ...

  1. Middle-term results of trans-catheter creation of atrial communication in patients receiving mechanical circulatory support.

    PubMed

    O'Byrne, Michael L; Glatz, Andrew C; Rossano, Joseph W; Schiavo, Kellie L; Dori, Yoav; Rome, Jonathan J; Gillespie, Matthew J

    2015-06-01

    To describe our center's middle-term outcomes following trans-catheter creation of atrial communication (ASD) in patients on mechanical circulatory support. Trans-catheter creation of an ASD in patients on mechanical circulatory support is an adjuvant therapy to reduce left atrial pressure and associated morbidity. Data on middle term outcomes following this procedure, specifically in regards to the fate of the ASD, are limited. Retrospective observational study of consecutive children and adults undergoing trans-catheter creation of an atrial septal communication between 1/1/2006 and 5/1/2014, reviewing their baseline characteristics, procedural details, and data from follow-up. Over the study period, 37/227 (16%) subjects undergoing veno-arterial extra-corporeal membrane oxygenation (VA-ECMO) underwent trans-catheter creation of an atrial communication. Mortality on VA-ECMO support in this subgroup was 19%, with an additional 24% transitioning to ventricular assist device. Of the 57% who survived to separation from VA-ECMO, 16/21 (76%) had residual atrial communications. 56% of these underwent closure procedures. Following trans-catheter creation of ASD, a residual ASD is present in the majority of assessable survivors and represents a potential volume overload and/or right to left shunt that may need to be addressed. © 2015 Wiley Periodicals, Inc.

  2. Incidence, Patterns, and Factors Predicting Mortality of Abdominal Injuries in Trauma Patients

    PubMed Central

    Gad, Mohammad A; Saber, Aly; Farrag, Shereif; Shams, Mohamed E; Ellabban, Goda M

    2012-01-01

    Background: Abdominal trauma is a major public health problem for all nations and all socioeconomic strata. Aim: This study was designed to determine the incidence and patterns of abdominal injuries in trauma patients. Materials and Methods: We classified and identified the incidence and subtype of abdominal injuries and associated trauma, and identified variables related to morbidity and mortality. Results: Abdominal trauma was present in 248 of 300 cases; 172 patients with blunt abdominal trauma and 76 with penetrating. The most frequent type of abdominal trauma was blunt trauma; its most common cause was motor vehicle accident. Among patients with penetrating abdominal trauma, the most common cause was stabbing. Most abdominal trauma patients presented with other injuries, especially patients with blunt abdominal trauma. Mortality was higher among penetrating abdominal trauma patients. Conclusions: Type of abdominal trauma, associated injuries, and Revised Trauma Score are independent risk factors for mortality in abdominal trauma patients. PMID:22454826

  3. Impulse Pump

    DTIC Science & Technology

    2016-06-17

    APPLICATIONS [0002] None. BACKGROUND OF THE INVENTION (1) Field of the Invention [0003] The present invention relates to an impulse pump for generating...impulse pump 15. The sleeve bearings 98 are affixed to the head block 90 to ease axial motion while the plunger 72 is under torsional loads. [0041

  4. GAS METERING PUMP

    DOEpatents

    George, C.M.

    1957-12-31

    A liquid piston gas pump is described, capable of pumping minute amounts of gas in accurately measurable quantities. The pump consists of a flanged cylindrical regulating chamber and a mercury filled bellows. Sealed to the ABSTRACTS regulating chamber is a value and having a gas inlet and outlet, the inlet being connected by a helical channel to the bellows. A gravity check valve is in the gas outlet, so the gas passes through the inlet and the helical channel to the bellows where the pumping action as well as the metering is accomplished by the actuation of the mercury filled bellows. The gas then flows through the check valve and outlet to any associated apparatus.

  5. [Abdominal wall actinomycosis. A report of a case].

    PubMed

    Rojas Pérez-Ezquerra, Beatriz; Guardia-Dodorico, Lorena; Arribas-Marco, Teresa; Ania-Lahuerta, Aldonza; González Ballano, Isabel; Chipana-Salinas, Margot; Carazo-Hernández, Belén

    2015-01-01

    Abdominal wall Actinomycosis is a rare disease associated with the use of intrauterine device and as a complication of abdominal surgery. Diagnosis is difficult because it is unusual and behaves like a malignant neoplasm. A case report is presented of a patient who had used an intrauterine device for four years and developed a stony tumour in the abdominal wall associated with a set of symptoms that, clinically and radiologically, was simulating a peritoneal carcinomatosis associated with paraneoplastic syndrome, even in the course of an exploratory laparotomy. The patient attended our hospital with a two-month history of abdominal pain and symptoms that mimic a paraneoplastic syndrome. The diagnosis of abdominal actinomycosis was suspected by the finding of the microorganism in cervical cytology together with other cultures and Actinomyces negative in pathological studies, confirming the suspicion of a complete cure with empirical treatment with penicillin. Actinomycosis should be considered in patients with pelvic mass or abdominal wall mass that mimics a malignancy. Antibiotic therapy is the first treatment choice and makes a more invasive surgical management unnecessary. Copyright © 2015 Academia Mexicana de Cirugía A.C. Published by Masson Doyma México S.A. All rights reserved.

  6. Is there an association of circulatory hospitalizations independent of mining employment in coal-mining and non-coal-mining counties in west virginia?

    PubMed

    Talbott, Evelyn O; Sharma, Ravi K; Buchanich, Jeanine; Stacy, Shaina L

    2015-04-01

    Exposures associated with coal mining activities, including diesel fuel exhaust, products used in coal processing, and heavy metals and other forms of particulate matter, may impact the health of nearby residents. We investigated the relationships between county-level circulatory hospitalization rates (CHRs) in coal and non-coal-mining communities of West Virginia, coal production, coal employment, and sociodemographic factors. Direct age-adjusted CHRs were calculated using West Virginia hospitalizations from 2005 to 2009. Spatial regressions were conducted to explore associations between CHR and total, underground, and surface coal production. After adjustment, neither total, nor surface, nor underground coal production was significantly related to rate of hospitalization for circulatory disease. Our findings underscore the significant role sociodemographic and behavioral factors play in the health and well-being of coal mining communities.

  7. Bioprosthetic Mesh in Abdominal Wall Reconstruction

    PubMed Central

    Baumann, Donald P.; Butler, Charles E.

    2012-01-01

    Mesh materials have undergone a considerable evolution over the last several decades. There has been enhancement of biomechanical properties, improvement in manufacturing processes, and development of antiadhesive laminate synthetic meshes. The evolution of bioprosthetic mesh materials has markedly changed our indications and methods for complex abdominal wall reconstruction. The authors review the optimal properties of bioprosthetic mesh materials, their evolution over time, and their indications for use. The techniques to optimize outcomes are described using bioprosthetic mesh for complex abdominal wall reconstruction. Bioprosthetic mesh materials clearly have certain advantages over other implantable mesh materials in select indications. Appropriate patient selection and surgical technique are critical to the successful use of bioprosthetic materials for abdominal wall repair. PMID:23372454

  8. Functional Abdominal Pain: "Get" the Function, Loose the Pain.

    PubMed

    Draeger-Muenke, Reinhild

    2015-07-01

    Functional abdominal pain is a mind-body, psychosocial, and self-reinforcing experience with significant consequences for the sufferer and the surrounding support network. The occurrence of unpredictable symptoms and their severity add an element of dread and feeling out-of-control to daily life and often reduce overall functioning in a downward spiral. Two clinical presentations of functional abdominal pain are offered in this article (composites to protect confidentiality) dealing with abdominal pain syndrome and abdominal migraines. The treatment demonstrates the use of hypnotic principles for self-regulation, exploration, and meaning-making. Hypnosis treatment is conducted in combination with mindfulness-based interventions and Traditional Chinese Medicine's (TCM) teachings regarding abdominal health and illness. The clinical examples illustrate medical findings that suggest children with early life stress and an early onset of gastrointestinal somatization may not simply outgrow their functional abdominal pain but may suffer into adulthood.

  9. [Abdominal wall reconstruction with collagen membrane in an animal model of abdominal hernia. A preliminary report].

    PubMed

    Łukasiewicz, Aleksander; Drewa, Tomasz; Skopińska-Wiśniewska, Joanna; Molski, Stanisław

    2008-01-01

    Abdominal hernia repair is one of the most common surgical procedures. Current data indicate that the best treatment results are achieved with use of synthetic material to reinforce weakened abdominal wall. Prosthetic materials utilized for hernia repair induce adhesions with underlying viscera. They should be therefore separated from them by a layer of peritoneum otherwise adhesions may cause to serious complications such as bowel-skin fistulas. The aim of our work was to determine if implantation of our collagen membrane into abdominal wall defect induce adhesions in rat model of ventral hernia. The collagen film was obtained by acetic acid extraction of rat tail tendons and than casting the soluble fraction onto polyethylene shits. Abdominal wall defect was created in 10 Wistar male rats. Collagen membranes were implanted into the defect using interrupted polypropylene stitches. After 3 months of observation all animals were sacrificed. No adhesions between path structure and bowel developed. In one often rats (10%) adhesion between fixating stitch and omentum was observed. Complete mesothelium lining and vascular ingrowth were microscopically observed within implanted structure. Promising result requires further confirmation in a larger series of animals.

  10. [Implementationof a low FODMAP dietforfunctional abdominal pain].

    PubMed

    Baranguán Castro, María Luisa; Ros Arnal, Ignacio; García Romero, Ruth; Rodríguez Martínez, Gerardo; Ubalde Sainz, Eduardo

    2018-04-20

    The low FODMAP diet (fermentable oligosaccharides, monosaccharides, disaccharides, and polyols) has shown to be effective in adult patients with irritable bowel syndrome, but there are few studies on paediatric patients. The aim of this study is to assess the implementation and the outcomes of a low FODMAP diet in the treatment of functional abdominal pain in children from a Mediterranean area. A table was designed in which foods were classified according to their FODMAP content, as well as a 'Symptoms and Stools Diary'. A prospective study was conducted on children with functional abdominal pain in our Paediatric Gastroenterology Unit. A total of 22 patients were enrolled in the trial, and 20 completed it. Data were collected of the abdominal pain features over a period of 3 days, and then patients followed a two-week low FODMAP diet. Afterwards, information about abdominal pain features was collected again. After the diet, they showed fewer daily abdominal pain episodes compared to baseline (1.16 [IQR: 0.41-3.33] versus 2 [IQR: 1.33-6.33] daily episodes, P=.024), less pain severity compared to baseline (1.41cm [IQR: 0.32-5.23] versus 4.63cm [IQR: 2.51-6.39] measured by 10-cm Visual Analogue Scale, P=.035), less interference with daily activities, and less gastrointestinal symptoms. Only 15% of patients found it difficult to follow the diet. The implementation of a low FODMAP diet for 2 weeks in a Mediterranean paediatric population diagnosed with functional abdominal pain is possible with adapted diets. It was highly valued by patients, and they showed an improvement in abdominal pain symptoms assessed by objective methods. Copyright © 2018. Publicado por Elsevier España, S.L.U.

  11. Design analysis and performance assessment of hybrid magnetic bearings for a rotary centrifugal blood pump.

    PubMed

    Ren, Zhaohui; Jahanmir, Said; Heshmat, Hooshang; Hunsberger, Andrew Z; Walton, James F

    2009-01-01

    A hybrid magnetic bearing system was designed for a rotary centrifugal blood pump being developed to provide long-term circulatory support for heart failure patients. This design consists of two compact bearings to suspend the rotor in five degrees-of-freedom with single axis active control. Permanent magnets are used to provide passive radial support and electromagnets to maintain axial stability of the rotor. Characteristics of the passive radial and active thrust magnetic bearing system were evaluated by the electromagnetic finite element analysis. A proportional-integral-derivative controller with force balance algorithm was implemented for closed loop control of the magnetic thrust bearing. The control position is continuously adjusted based on the electrical energy in the bearing coils, and thus passive magnetic forces carry static thrust loads to minimize the bearing current. Performance of the magnetic bearing system with associated control algorithm was evaluated at different operating conditions. The bearing current was significantly reduced with the force balance control method and the power consumption was below 0.5 W under various thrust loads. The bearing parameters predicted by the analysis were validated by the experimental data.

  12. Factors associated with abdominal obesity in children

    PubMed Central

    Melzer, Matheus Ribeiro Theodósio Fernandes; Magrini, Isabella Mastrangi; Domene, Semíramis Martins Álvares; Martins, Paula Andrea

    2015-01-01

    Objective: To identify the association of dietary, socioeconomic factors, sedentary behaviors and maternal nutritional status with abdominal obesity in children. Methods: A cross-sectional study with household-based survey, in 36 randomly selected census tracts in the city of Santos, SP. 357 families were interviewed and questionnaires and anthropometric measurements were applied in mothers and their 3-10 years-old children. Assessment of abdominal obesity was made by maternal and child's waist circumference measurement; for classification used cut-off points proposed by World Health Organization (1998) and Taylor et al. (2000) were applied. The association between variables was performed by multiple logistic regression analysis. Results: 30.5% of children had abdominal obesity. Associations with children's and maternal nutritional status and high socioeconomic status were shown in the univariate analysis. In the regression model, children's body mass index for age (OR=93.7; 95%CI 39.3-223.3), female gender (OR=4.1; 95%CI 1.8-9.3) and maternal abdominal obesity (OR=2.7; 95%CI 1.2-6.0) were significantly associated with children's abdominal obesity, regardless of the socioeconomic status. Conclusions: Abdominal obesity in children seems to be associated with maternal nutritional status, other indicators of their own nutritional status and female gender. Intervention programs for control of childhood obesity and prevention of metabolic syndrome should consider the interaction of the nutritional status of mothers and their children. PMID:26298655

  13. [Factors associated with abdominal obesity in children].

    PubMed

    Melzer, Matheus Ribeiro Theodósio Fernandes; Magrini, Isabella Mastrangi; Domene, Semíramis Martins Álvares; Martins, Paula Andrea

    2015-12-01

    To identify the association of dietary, socioeconomic factors, sedentary behaviors and maternal nutritional status with abdominal obesity in children. A cross-sectional study with household-based survey, in 36 randomly selected census tracts in the city of Santos/SP. 357 families were interviewed and questionnaires and anthropometric measurements were applied in mothers and their 3-0 years-old children. Assessment of abdominal obesity was made by maternal and child's waist circumference measurement; for classification used cut-off points proposed by World Health Organization (1998) and Taylor et al. (2000) were applied. The association between variables was performed by multiple logistic regression analysis. 30.5% of children had abdominal obesity. Associations with children's and maternal nutritional status and high socioeconomic status were shown in the univariate analysis. In the regression model, children's body mass index for age (OR=93.7; 95%CI 39.3-223.3), female gender (OR=4.1; 95%CI 1.8-9.3) and maternal abdominal obesity (OR=2.7; 95%CI 1.2-6.0) were significantly associated with children's abdominal obesity, regardless of the socioeconomic status. Abdominal obesity in children seems to be associated with maternal nutritional status, other indicators of their own nutritional status and female gender. Intervention programs for control of childhood obesity and prevention of metabolic syndrome should consider the interaction of the nutritional status of mothers and their children. Copyright © 2015 Sociedade de Pediatria de São Paulo. Publicado por Elsevier Editora Ltda. All rights reserved.

  14. Electroosmotic pump performance is affected by concentration polarizations of both electrodes and pump

    PubMed Central

    Suss, Matthew E.; Mani, Ali; Zangle, Thomas A.; Santiago, Juan G.

    2010-01-01

    Current methods of optimizing electroosmotic (EO) pump performance include reducing pore diameter and reducing ionic strength of the pumped electrolyte. However, these approaches each increase the fraction of total ionic current carried by diffuse electric double layer (EDL) counterions. When this fraction becomes significant, concentration polarization (CP) effects become important, and traditional EO pump models are no longer valid. We here report on the first simultaneous concentration field measurements, pH visualizations, flow rate, and voltage measurements on such systems. Together, these measurements elucidate key parameters affecting EO pump performance in the CP dominated regime. Concentration field visualizations show propagating CP enrichment and depletion fronts sourced by our pump substrate and traveling at order mm/min velocities through millimeter-scale channels connected serially to our pump. The observed propagation in millimeter-scale channels is not explained by current propagating CP models. Additionally, visualizations show that CP fronts are sourced by and propagate from the electrodes of our system, and then interact with the EO pump-generated CP zones. With pH visualizations, we directly detect that electrolyte properties vary sharply across the anode enrichment front interface. Our observations lead us to hypothesize possible mechanisms for the propagation of both pump- and electrode-sourced CP zones. Lastly, our experiments show the dynamics associated with the interaction of electrode and membrane CP fronts, and we describe the effect of these phenomena on EO pump flow rates and applied voltages under galvanostatic conditions. PMID:21516230

  15. Darrieus wind-turbine and pump performance for low-lift irrigation pumping

    NASA Astrophysics Data System (ADS)

    Hagen, L. J.; Sharif, M.

    1981-10-01

    In the Great Plains about 15 percent of the irrigation water pumped on farms comes from surface water sources; for the United States as a whole, the figure is about 22 percent. Because of forecast fuel shortages, there is a need to develop alternative energy sources such as wind power for surface water pumping. Specific objectives of this investigation were to: design and assemble a prototype wind powered pumping system for low lift irrigation pumping; determine performance of the prototype system; design and test an irrigation system using the wind powered prototype in a design and test an farm application; and determine the size combinations of wind turbines, tailwater pits, and temporary storage reservoirs needed for successful farm application of wind powered tailwater pumping systems in western Kansas. The power source selected was a two bladed, 6 m diameter, 9 m tall Darrieus vertical axis wind turbine with 0.10 solidity and 36.1 M(2) swept area.

  16. Pump Diode Characterization for an Unstable Diode-Pumped Alkali Laser Resonator

    DTIC Science & Technology

    2013-03-01

    2003. Petersen, A., and R. Lane, Second harmonic operation of diode-pumped Rb vapor lasers , Proc. of SPIE, 7005, 2008. Siegman , A. E., Lasers ...University Science Books, Sausalito, CA, 1986. Siegman , A. E., Defining, measuring and optimizing laser beam quality, Proc. of SPIE, 1868, 1993. Steck, D...PUMP DIODE CHARACTERIZATION FOR AN UNSTABLE DIODE-PUMPED ALKALI LASER RESONATOR THESIS Chad T. Taguba, Master Sergeant, USAF AFIT-ENP-13-M-33

  17. DIRECT CURRENT ELECTROMAGNETIC PUMP

    DOEpatents

    Barnes, A.H.

    1957-11-01

    An improved d-c electromagnetic pump is presented in which the poles, and consequently the magetic gap at the poles, are tapered to be wider at the upstream end. In addition, the cross section of the tube carryiQ the liquid metal is tapered so that the velocity of the pumped liquid increases in the downstream direction at a rate such that the counter-induced voltage in the liquid metal remains constant as it traverses the region between the poles. This configuration compensates for the distortion of the magnetic field caused by the induced voltage that would otherwise result in the lowering of the pumping capacity. This improved electromagnetic pump as practical application in the pumping of liquid metal coolants for nuclear reactors where conventional positive displacement pumps have proved unsatisfactory due to the high temperatures and the corrosive properties of the liquid metals involved.

  18. Abdominal x-ray

    MedlinePlus

    ... are, or may be, pregnant. Alternative Names Abdominal film; X-ray - abdomen; Flat plate; KUB x-ray ... Guidelines Viewers & Players MedlinePlus Connect for EHRs For Developers U.S. National Library of Medicine 8600 Rockville Pike, ...

  19. Abdominal ultrasound (image)

    MedlinePlus

    Abdominal ultrasound is a scanning technique used to image the interior of the abdomen. Like the X-ray, MRI, ... it has its place as a diagnostic tool. Ultrasound scans use high frequency sound waves to produce ...

  20. Abdominal ultrasound and medical education.

    PubMed

    García de Casasola Sánchez, G; Torres Macho, J; Casas Rojo, J M; Cubo Romano, P; Antón Santos, J M; Villena Garrido, V; Diez Lobato, R

    2014-04-01

    Ultrasound is a very versatile diagnostic modality that permits real-time visualization of multiple internal organs. It is of invaluable help for the physical examination of the patients. To assess if ultrasound can be incorporated into medical education and if the students can perform a basic abdominal ultrasound examination without the necessity of a long period of training. Twelve medical students were trained in basic abdominal ultrasound during a 15-h training program including a 5-h theoretical and practical course and supervised practice in 20 selected patients. Subsequently, we conducted an evaluation test that assessed the ability of students to obtain the ultrasound views and to detect various pathologies in five different patients. The students were able to correctly identify the abdominal views more than 90% of the times. This percentage was only lower (80%) in the right subcostal view to locate the gallbladder. The accuracy or global efficiency of the ultrasound for the diagnosis of relevant pathological findings of the patients was greater than 90% (91.1% gallstones, abdominal aortic aneurysm 100%; splenomegaly 98.3%, ascites 100%; dilated inferior vena cava 100%; acute urinary retention 100%). The ultrasound may be a feasible learning tool in medical education. Ultrasound can help students to improve the physical examination. Copyright © 2013 Elsevier España, S.L. All rights reserved.